A new method of snowmelt sampling for water stable isotopes
Penna, D.; Ahmad, M.; Birks, S. J.; Bouchaou, L.; Brencic, M.; Butt, S.; Holko, L.; Jeelani, G.; Martinez, D. E.; Melikadze, G.; Shanley, J.B.; Sokratov, S. A.; Stadnyk, T.; Sugimoto, A.; Vreca, P.
2014-01-01
We modified a passive capillary sampler (PCS) to collect snowmelt water for isotopic analysis. Past applications of PCSs have been to sample soil water, but the novel aspect of this study was the placement of the PCSs at the ground-snowpack interface to collect snowmelt. We deployed arrays of PCSs at 11 sites in ten partner countries on five continents representing a range of climate and snow cover worldwide. The PCS reliably collected snowmelt at all sites and caused negligible evaporative fractionation effects in the samples. PCS is low-cost, easy to install, and collects a representative integrated snowmelt sample throughout the melt season or at the melt event scale. Unlike snow cores, the PCS collects the water that would actually infiltrate the soil; thus, its isotopic composition is appropriate to use for tracing snowmelt water through the hydrologic cycle. The purpose of this Briefing is to show the potential advantages of PCSs and recommend guidelines for constructing and installing them based on our preliminary results from two snowmelt seasons.
INNOVATIVE TECHNOLOGY EVALUATION REPORT ...
The Split Core Sampler for Submerged Sediments (Split Core Sampler) designed and fabricated by Arts Manufacturing & Supply, Inc., was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the samplers ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Split Core Sampler and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Split Core Sampler performed as well as or better than the reference samplers. Based on visual observations, both the Split Core Sampler and reference samplers collected partially compressed samples of consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved for both consolidated and unconsolidated sediment samples collected by the Split Core Sampler and reference samplers. No sampler was able to collect samples
The Split Core Sampler for Submerged Sediments (Split Core Sampler) designed and fabricated by Arts Manufacturing & Supply, Inc., was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at ...
Improvement of core drill methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gatz, J.L.
1975-07-01
This report documents results of a program to evaluate effectiveness of more or less conventional subsurface samplers in obtaining representative and undisturbed samples of noncohesive alluvial materials containing large quantities of gravels and cobbles. This is the first phase of a research program to improve core drill methods. Samplers evaluated consisted of the Lawrence Livermore Laboratory membrane sampler, 4-in. Denison sampler, 6-in. Dension sampler, 5-in. Modified Denison sampler, and 3-in. thinwall drive tube. Small representative samples were obtained with the Dension samplers; no undisturbed samples were obtained. The field work was accomplished in the Rhodes Canyon area, White Sands Misslemore » Range, New Mexico.« less
An improved tri-tube cryogenic gravel sampler.
Fred H. Everest; Carl E. McLemore; John F. Ward
1980-01-01
The tri-tube cryogenic gravel sampler has been improved, and accessories have been developed that increase its reliability and safety of operation, reduce core extraction time, and allow accurate partitioning of cores into subsamples. The improved tri-tube sampler is one of the most versatile and efficient substrate sampling tools yet developed.
Methods for Determining Particle Size Distributions from Nuclear Detonations.
1987-03-01
Debris . . . 30 IV. Summary of Sample Preparation Method . . . . 35 V. Set Parameters for PCS ... ........... 39 VI. Analysis by Vendors...54 XV. Results From Brookhaven Analysis Using The Method of Cumulants ... ........... . 54 XVI. Results From Brookhaven Analysis of Sample...R-3 Using Histogram Method ......... .55 XVII. Results From Brookhaven Analysis of Sample R-8 Using Histogram Method ........... 56 XVIII.TEM Particle
A sampler for coring sediments in rivers and estuaries
Prych, Edmund A.; Hubbell, D.W.
1966-01-01
A portable sampler developed to core submerged unconsolidated sediments collects cores that are 180 cm long and 4.75cm in diameter. The sampler is used from a 12-m boat in water depths up to 20 m and in flow velocities up to 1.5m per second to sample river and estuarine deposits ranging from silty clay to medium sand. Even in sand that cannot be penetrated with conventional corers, the sampler achieves easy penetration through the combined application of vibration, suction, and axial force. A piston in the core barrel creates suction, and the suspension system is arranged so that tension on the support cable produces both a downward force on the core barrel and a lateral support against overturning. Samples are usually retained because of slight compaction in the driving head; as a precaution, however, the bottom of the core barrel is covered by a plate that closes after the barrel is withdrawn from the bed. Tests show that sample-retainers placed within the driving head restrict penetration and limit core lengths. Stratification within cores is disrupted little as a result of the sampling process.
INNOVATIVE TECHNOLOGY EVALUATION REPORT ...
The Russian Peat Borer designed and fabricated by Aquatic Research Instruments was demonstrated under the U.S. Environmental Protection Agency (EPA) Superfund Innovative Technology Evaluation Program in April and May 1999 at sites in EPA Regions 1 and 5, respectively. In addition to assessing ease of sampler operation, key objectives of the demonstration included evaluating the sampler?s ability to (1) consistently collect a given volume of sediment, (2) consistently collect sediment in a given depth interval, (3) collect samples with consistent characteristics from a homogenous layer of sediment, and (4) collect samples under a variety of site conditions. This report describes the demonstration results for the Russian Peat Borer and two conventional samplers (the Hand Corer and Vibrocorer) used as reference samplers. During the demonstration, the Russian Peat Borer was the only sampler that collected samples in the deep depth interval (4 to 11 feet below sediment surface). It collected representative and relatively uncompressed core samples of consolidated sediment in discrete depth intervals. The reference samplers collected relatively compressed samples of both consolidated and unconsolidated sediments from the sediment surface downward; sample representativeness may be questionable because of core shortening and core compression. Sediment stratification was preserved only for consolidated sediment samples collected by the Russian Peat Borer but for bo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D. H.; Reigel, M. M.
A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposedmore » to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.« less
Liu, Dongfei; Chen, Li; Jiang, Sunmin; Zhu, Shuning; Qian, Yong; Wang, Fengzhen; Li, Rui; Xu, Qunwei
2014-03-01
To successfully prepare the diclofenac sodium (DS)-loaded solid lipid nanoparticles (SLNs), phospholipid complexes (PCs) technology was applied here to improve the liposolubility of DS. Solid lipid nanoparticles (SLNs) loaded with phospholipid complexes (PCs) were prepared by the modified emulsion/solvent evaporation method. DS could be solubilized effectively in the organic solvents with the existence of phospholipid and apparent partition coefficient of DS in PCs increased significantly. X-ray diffraction analysis suggested that DS in PCs was either molecularly dispersed or in an amorphous form. However, no significant difference was observed between the Fourier transform infrared spectroscopy (FT-IR) spectra of physical mixture and that of PCs. Particles with small sizes, narrow polydispersity indexes and high entrapment efficiencies could be obtained with the addition of PCs. Furthermore, according to the transmission electron microscopy, a core-shell structure was likely to be formed. The presence of PCs caused the change of zeta potential and retarded the drug release of SLNs, which indicated that phospholipid formed multilayers around the solid lipid core of SLNs. Both FT-IR and differential scanning calorimetry analysis also illustrated that some weak interactions between DS and lipid materials might take place during the preparation of SLNs. In conclusion, the model hydrophilic drug-DS can be formulated into the SLNs with the help of PCs.
PCS optical fibers for an automobile data bus
NASA Astrophysics Data System (ADS)
Clarkin, James P.; Timmerman, Richard J.; Stolte, Gary W.; Klein, Karl-Friedrich
2005-02-01
Optical fibers have been used for data communications in automobiles for several years. The fiber of choice thus far has been a plastic core/plastic clad optical fiber (POF) consisting of the plastic polymethylmethacrylate (PMMA). The POF fiber provides a low cost fiber with relatively easy termination. However, increasing demands regarding temperature performance, transmission losses and bandwidth have pushed the current limits of the POF fiber, and the automotive industry is now moving towards an optical fiber with a silica glass core/plastic clad (PCS). PCS optical fibers have been used successfully in industrial, medical, sensor, military and data communications systems for over two decades. The PCS fiber is now being adapted specifically for automotive use. In the following, the design criteria and design alternatives for the PCS as well as optical, thermal, and mechanical testing results for key automotive parameters are described. The fiber design tested was 200&mum synthetic silica core/230&mum fluoropolymer cladding/1510&mum nylon buffer. Key attributes such as 700 - 900 nm spectral attenuation, 125°C thermal soak, -40 to 125°C thermal cycling, bending losses, mechanical strength, termination capability, and cost are discussed and compared. Overall, a specifically designed PCS fiber is expected to be acceptable for the use in an automotive data bus, and will show improvement in optical transmission, temperature range and bandwidth. However, the final selection of buffer and jacket materials and properties will be most dependent on the selection of a reliable and economical termination method.
Ishiwata, Takumi; Michibata, Ayano; Kokado, Kenta; Ferlay, Sylvie; Hosseini, Mir Wais; Sada, Kazuki
2018-02-06
New polymer capsules (PCs) were obtained using a crystal crosslinking (CC) method on core-shell MOF crystals. The latter are based on the epitaxial growth of two isostructural coordination polymers which are then selectively crosslinked. Decomposition of the non-reticulated phase leads to new PCs, possessing a well-defined hollow cubic shape reflecting the heterostructure of the template.
Structure-Property Relationships for Tailoring Phenoxazines as Reducing Photoredox Catalysts.
McCarthy, Blaine G; Pearson, Ryan M; Lim, Chern-Hooi; Sartor, Steven M; Damrauer, Niels H; Miyake, Garret M
2018-04-18
Through the study of structure-property relationships using a combination of experimental and computational analyses, a number of phenoxazine derivatives have been developed as visible light absorbing, organic photoredox catalysts (PCs) with excited state reduction potentials rivaling those of highly reducing transition metal PCs. Time-dependent density functional theory (TD-DFT) computational modeling of the photoexcitation of N-aryl and core modified phenoxazines guided the design of PCs with absorption profiles in the visible regime. In accordance with our previous work with N, N-diaryl dihydrophenazines, characterization of noncore modified N-aryl phenoxazines in the excited state demonstrated that the nature of the N-aryl substituent dictates the ability of the PC to access a charge transfer excited state. However, our current analysis of core modified phenoxazines revealed that these molecules can access a different type of CT excited state which we posit involves a core substituent as the electron acceptor. Modification of the core of phenoxazine derivatives with electron-donating and electron-withdrawing substituents was used to alter triplet energies, excited state reduction potentials, and oxidation potentials of the phenoxazine derivatives. The catalytic activity of these molecules was explored using organocatalyzed atom transfer radical polymerization (O-ATRP) for the synthesis of poly(methyl methacrylate) (PMMA) using white light irradiation. All of the derivatives were determined to be suitable PCs for O-ATRP as indicated by a linear growth of polymer molecular weight as a function of monomer conversion and the ability to synthesize PMMA with moderate to low dispersity (dispersity less than or equal to 1.5) and initiator efficiencies typically greater than 70% at high conversions. However, only PCs that exhibit strong absorption of visible light and strong triplet excited state reduction potentials maintain control over the polymerization during the entire course of the reaction. The structure-property relationships established here will enable the application of these organic PCs for O-ATRP and other photoredox-catalyzed small molecule and polymer syntheses.
The San Dimas Soil Core Sampler
L. A. Andrews; W. M. Broadfoot
1958-01-01
The search for satisfactory methods of sampling soils for various purposes under a wide variety of conditions has led to the development of the equally wide variety of soil samplers described by Hoover, Olson, and Metz (5), Lull and Reinhart (8), and the U. S. Dept. Agr. Soil Survey staff (11). Although many of these samplers proved successful for the particular...
Influence of item distribution pattern and abundance on efficiency of benthic core sampling
Behney, Adam C.; O'Shaughnessy, Ryan; Eichholz, Michael W.; Stafford, Joshua D.
2014-01-01
ore sampling is a commonly used method to estimate benthic item density, but little information exists about factors influencing the accuracy and time-efficiency of this method. We simulated core sampling in a Geographic Information System framework by generating points (benthic items) and polygons (core samplers) to assess how sample size (number of core samples), core sampler size (cm2), distribution of benthic items, and item density affected the bias and precision of estimates of density, the detection probability of items, and the time-costs. When items were distributed randomly versus clumped, bias decreased and precision increased with increasing sample size and increased slightly with increasing core sampler size. Bias and precision were only affected by benthic item density at very low values (500–1,000 items/m2). Detection probability (the probability of capturing ≥ 1 item in a core sample if it is available for sampling) was substantially greater when items were distributed randomly as opposed to clumped. Taking more small diameter core samples was always more time-efficient than taking fewer large diameter samples. We are unable to present a single, optimal sample size, but provide information for researchers and managers to derive optimal sample sizes dependent on their research goals and environmental conditions.
Bourgeois, Peter M.; Reger, Robert J.
1996-01-01
A variable depth core sampler apparatus comprising a first circular hole saw member, having longitudinal sections that collapses to form a point and capture a sample, and a second circular hole saw member residing inside said first hole saw member to support the longitudinal sections of said first hole saw member and prevent them from collapsing to form a point. The second hole saw member may be raised and lowered inside said first hole saw member.
Care, Matthew A.; Stephenson, Sophie J.; Barnes, Nicholas A.; Fan, Im; Zougman, Alexandre; El-Sherbiny, Yasser M.; Vital, Edward M.; Westhead, David R.; Tooze, Reuben M.
2016-01-01
Plasma cells (PCs) as effectors of humoral immunity produce Igs to match pathogenic insult. Emerging data suggest more diverse roles exist for PCs as regulators of immune and inflammatory responses via secretion of factors other than Igs. The extent to which such responses are preprogrammed in B-lineage cells or can be induced in PCs by the microenvironment is unknown. In this study, we dissect the impact of IFNs on the regulatory networks of human PCs. We show that core PC programs are unaffected, whereas PCs respond to IFNs with distinctive transcriptional responses. The IFN-stimulated gene 15 (ISG15) system emerges as a major transcriptional output induced in a sustained fashion by IFN-α in PCs and linked both to intracellular conjugation and ISG15 secretion. This leads to the identification of ISG15-secreting plasmablasts/PCs in patients with active systemic lupus erythematosus. Thus, ISG15-secreting PCs represent a distinct proinflammatory PC subset providing an Ig-independent mechanism of PC action in human autoimmunity. PMID:27357150
Bourgeois, P.M.; Reger, R.J.
1996-02-20
A variable depth core sampler apparatus is described comprising a first circular hole saw member, having longitudinal sections that collapses to form a point and capture a sample, and a second circular hole saw member residing inside said first hole saw member to support the longitudinal sections of said first hole saw member and prevent them from collapsing to form a point. The second hole saw member may be raised and lowered inside said first hole saw member. 7 figs.
Comparison of Three Biomass Sampling Techniques on Submersed Aquatic Plants in a Northern Tier Lake
2010-07-01
distribution in 3 out of 14 species when comparing the box-core sampler and the rake method. These included forked duckweed (Lemna trisulca L, p...each site did not exhibit differences. These included coontail (p=0.2949), muskgrass (p=0.2746), American elodea (p=0.7622), forked duckweed (p...collected by the PVC-core sampler. These included coontail (p=0.000), chara (p=0.0219), American elodea (p=0.0061), forked duckweed (p=0.0000), najas (p
A sample-freezing drive shoe for a wire line piston core sampler
Murphy, F.; Herkelrath, W.N.
1996-01-01
Loss of fluids and samples during retrieval of cores of saturated, noncohesive sediments results in incorrect measures of fluid distributions and an inaccurate measure of the stratigraphic position of the sample. To reduce these errors, we developed a hollow drive shoe that freezes in place the lowest 3 inches (75 mm) of a 1.88-inch-diameter (48 mm), 5-foot-long (1.5 m) sediment sample taken using a commercial wire line piston core sampler. The end of the core is frozen by piping liquid carbon dioxide at ambient temperature through a steel tube from a bottle at the land surface to the drive shoe where it evaporates and expands, cooling the interior surface of the shoe to about -109??F (-78??C). Freezing a core end takes about 10 minutes. The device was used to collect samples for a study of oil-water-air distributions, and for studies of water chemistry and microbial activity in unconsolidated sediments at the site of an oil spill near Bemidji, Minnesota. Before freezing was employed, samples of sandy sediments from near the water table sometimes flowed out of the core barrel as the sampler was withdrawn. Freezing the bottom of the core allowed for the retention of all material that entered the core barrel and lessened the redistribution of fluids within the core. The device is useful in the unsaturated and shallow saturated zones, but does not freeze cores well at depths greater than about 20 feet (6 m) below water, possibly because the feed tube plugs with dry ice with increased exhaust back-pressure, or because sediment enters the annulus between the core barrel and the core barrel liner and blocks the exhaust.
Inoue, Hiroyuki; Decker, Stephen R.; Taylor, Larry E.; ...
2014-10-09
Background: Enzymatic hydrolysis of pretreated lignocellulosic biomass is an essential process for the production of fermentable sugars for industrial use. A better understanding of fungal cellulase systems will provide clues for maximizing the hydrolysis of target biomass. Talaromyces cellulolyticus is a promising fungus for cellulase production and efficient biomass hydrolysis. Several cellulolytic enzymes purified from T. cellulolyticus were characterized in earlier studies, but the core enzymes critical for hydrolysis of lignocellulosic biomass remain unknown. Results: Six cellulolytic enzymes critical for the hydrolysis of crystalline cellulose were purified from T. cellulolyticus culture supernatant using an enzyme assay based on synergistic hydrolysismore » of Avicel. The purified enzymes were identified by their substrate specificities and analyses of trypsin-digested peptide fragments and were classified into the following glycosyl hydrolase (GH) families: GH3 (β-glucosidase, Bgl3A), GH5 (endoglucanase, Cel5A), GH6 (cellobiohydrolase II, Cel6A), GH7 (cellobiohydrolase I and endoglucanase, Cel7A and Cel7B, respectively), and GH10 (xylanase, Xyl10A). Hydrolysis of dilute acid-pretreated corn stover (PCS) with mixtures of the purified enzymes showed that Cel5A, Cel7B, and Xyl10A each had synergistic effects with a mixture of Cel6A and Cel7A. Cel5A seemed to be more effective in the synergistic hydrolysis of the PCS than Cel7B. The ratio of Cel5A, Cel6A, Cel7A, and Xyl10A was statistically optimized for the hydrolysis of PCS glucan in the presence of Bgl3A. The resultant mixture achieved higher PCS glucan hydrolysis at lower enzyme loading than a culture filtrate from T. cellulolyticus or a commercial enzyme preparation, demonstrating that the five enzymes play a role as core enzymes in the hydrolysis of PCS glucan. In Conclusion: Core cellulolytic enzymes in the T. cellulolyticus cellulase system were identified to Cel5A, Cel6A, Cel7A, Xyl10A, and Bgl3A and characterized. The optimized mixture of these five enzymes was highly effective for the hydrolysis of PCS glucan, providing a foundation for future improvement of the T. cellulolyticus cellulase system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Inoue, Hiroyuki; Decker, Stephen R.; Taylor, Larry E.
Background: Enzymatic hydrolysis of pretreated lignocellulosic biomass is an essential process for the production of fermentable sugars for industrial use. A better understanding of fungal cellulase systems will provide clues for maximizing the hydrolysis of target biomass. Talaromyces cellulolyticus is a promising fungus for cellulase production and efficient biomass hydrolysis. Several cellulolytic enzymes purified from T. cellulolyticus were characterized in earlier studies, but the core enzymes critical for hydrolysis of lignocellulosic biomass remain unknown. Results: Six cellulolytic enzymes critical for the hydrolysis of crystalline cellulose were purified from T. cellulolyticus culture supernatant using an enzyme assay based on synergistic hydrolysismore » of Avicel. The purified enzymes were identified by their substrate specificities and analyses of trypsin-digested peptide fragments and were classified into the following glycosyl hydrolase (GH) families: GH3 (β-glucosidase, Bgl3A), GH5 (endoglucanase, Cel5A), GH6 (cellobiohydrolase II, Cel6A), GH7 (cellobiohydrolase I and endoglucanase, Cel7A and Cel7B, respectively), and GH10 (xylanase, Xyl10A). Hydrolysis of dilute acid-pretreated corn stover (PCS) with mixtures of the purified enzymes showed that Cel5A, Cel7B, and Xyl10A each had synergistic effects with a mixture of Cel6A and Cel7A. Cel5A seemed to be more effective in the synergistic hydrolysis of the PCS than Cel7B. The ratio of Cel5A, Cel6A, Cel7A, and Xyl10A was statistically optimized for the hydrolysis of PCS glucan in the presence of Bgl3A. The resultant mixture achieved higher PCS glucan hydrolysis at lower enzyme loading than a culture filtrate from T. cellulolyticus or a commercial enzyme preparation, demonstrating that the five enzymes play a role as core enzymes in the hydrolysis of PCS glucan. In Conclusion: Core cellulolytic enzymes in the T. cellulolyticus cellulase system were identified to Cel5A, Cel6A, Cel7A, Xyl10A, and Bgl3A and characterized. The optimized mixture of these five enzymes was highly effective for the hydrolysis of PCS glucan, providing a foundation for future improvement of the T. cellulolyticus cellulase system.« less
Zhang, Yuqi; Gao, Loujun; Heng, Liping; Wei, Qingbo; Yang, Hua; Wang, Qiao
2013-03-01
The photonic crystals (PCs) films with tunable wettability were fabricated from self-assembly of an amphiphilic latex nano/microspheres poly(styrene-acrylamide) at different temperatures. The results demonstrate that the surface wettability of the PCs film can be tuned from high hydrophilic (CA, 17 degrees) to high hydrophobic (CA, 127.8 degrees) by controlling the assembly temperature from 30 degrees C to 90 degrees C, while the position of the photonic stopbands of the PCs films unchanged virtually. The obvious wettability transition is due to the change of the surface chemical component of the latex spheres, which mainly derives from the phase separation of polymer segments driven toward minimum interfacial energy. The facile method could open new application fields of PCs in diverse environments.
A Proteasome Cap Subunit Required for Spindle Pole Body Duplication in Yeast
McDonald, Heather B.; Byers, Breck
1997-01-01
Proteasome-mediated protein degradation is a key regulatory mechanism in a diversity of complex processes, including the control of cell cycle progression. The selection of substrates for degradation clearly depends on the specificity of ubiquitination mechanisms, but further regulation may occur within the proteasomal 19S cap complexes, which attach to the ends of the 20S proteolytic core and are thought to control entry of substrates into the core. We have characterized a gene from Saccharomyces cerevisiae that displays extensive sequence similarity to members of a family of ATPases that are components of the 19S complex, including human subunit p42 and S. cerevisiae SUG1/ CIM3 and CIM5 products. This gene, termed PCS1 (for proteasomal cap subunit), is identical to the recently described SUG2 gene (Russell, S.J., U.G. Sathyanarayana, and S.A. Johnston. 1996. J. Biol. Chem. 271:32810– 32817). We have shown that PCS1 function is essential for viability. A temperature-sensitive pcs1 strain arrests principally in the second cycle after transfer to the restrictive temperature, blocking as large-budded cells with a G2 content of unsegregated DNA. EM reveals that each arrested pcs1 cell has failed to duplicate its spindle pole body (SPB), which becomes enlarged as in other monopolar mutants. Additionally, we have shown localization of a functional Pcs1–green fluorescent protein fusion to the nucleus throughout the cell cycle. We hypothesize that Pcs1p plays a role in the degradation of certain potentially nuclear component(s) in a manner that specifically is required for SPB duplication. PMID:9151663
NASA Astrophysics Data System (ADS)
Rauert, Cassandra; Harner, Tom
2016-09-01
The suitability of Red Pine trees (Pinus Resinosa) to act as passive samplers for persistent organic pollutants (POPs) in outdoor air and to provide historic information on air concentration trends was demonstrated in this preliminary investigation. Red Pine tree cores from Toronto, Canada, were tested for polycyclic aromatic hydrocarbon (PAHs), alkylated-PAHs, nitro and oxy-PAHs, polybrominated diphenyl ethers (PBDEs) and novel brominated flame retardants (novel BFRs). The PBDEs and novel BFRs demonstrated a similar relative contribution in cores representing 30 years of tree growth, to that reported in contemporary air samples. Analysis of tree ring segments of 5-15 years resulted in detectable concentrations of some PAHs and alk-PAHs and demonstrated a transition from petrogenic sources to pyrogenic sources over the period 1960-2015. A simple uptake model was developed that treats the tree rings as linear-phase passive air samplers. The bark infiltration factor, IFBARK, is a key parameter of the model that reflects the permeability of the bark to allow chemicals to be transferred from ambient air to the outer tree layer (cambium). An IFBARK of about 2% was derived for the Red Pine trees based on tree core and air monitoring data.
Song, Wenfang; Wang, Faming
2016-08-01
This study aimed to examine the effectiveness of a hybrid personal cooling system (PCS) in mitigating body heat stain while exercising in a hot environment. Eight subjects underwent two trials: PCS and CON (i.e. no cooling). All trials were conducted at an air temperature of 36 ± 0.5 °C and RH = 59 ± 5%. The key findings demonstrated that the PCS could significantly reduce the core temperature, mean skin temperature, heart rate and physiological strain index during both exercise and recovery periods (p < 0.05). Subjective perceptions were also significantly alleviated in PCS at the end of the exercise and during the recovery (p < 0.05). Besides, the PCS could also bring remarkable benefits in lowering local skin temperatures and in improving perceptual sensations in both upper and lower body during both exercise and recovery periods (p < 0.05). It was thus concluded that the hybrid PCS is effective in mitigating body heat strain while exercising in a hot environment. Practitioner Summary: In hot and humid environments, body heat dissipation through sweating is greatly restricted. Our newly developed hybrid PCS could effectively alleviate heat strain while exercising in hot environments. The findings contribute to the body of knowledge in improving the health and well-being of sportsmen while exercising in hot environments.
Data Acquisition System for Multi-Frequency Radar Flight Operations Preparation
NASA Technical Reports Server (NTRS)
Leachman, Jonathan
2010-01-01
A three-channel data acquisition system was developed for the NASA Multi-Frequency Radar (MFR) system. The system is based on a commercial-off-the-shelf (COTS) industrial PC (personal computer) and two dual-channel 14-bit digital receiver cards. The decimated complex envelope representations of the three radar signals are passed to the host PC via the PCI bus, and then processed in parallel by multiple cores of the PC CPU (central processing unit). The innovation is this parallelization of the radar data processing using multiple cores of a standard COTS multi-core CPU. The data processing portion of the data acquisition software was built using autonomous program modules or threads, which can run simultaneously on different cores. A master program module calculates the optimal number of processing threads, launches them, and continually supplies each with data. The benefit of this new parallel software architecture is that COTS PCs can be used to implement increasingly complex processing algorithms on an increasing number of radar range gates and data rates. As new PCs become available with higher numbers of CPU cores, the software will automatically utilize the additional computational capacity.
In planta passive sampling devices for assessing subsurface chlorinated solvents.
Shetty, Mikhil K; Limmer, Matt A; Waltermire, Kendra; Morrison, Glenn C; Burken, Joel G
2014-06-01
Contaminant concentrations in trees have been used to delineate groundwater contaminant plumes (i.e., phytoscreening); however, variability in tree composition hinders accurate measurement of contaminant concentrations in planta, particularly for long-term monitoring. This study investigated in planta passive sampling devices (PSDs), termed solid phase samplers (SPSs) to be used as a surrogate tree core. Characteristics studied for five materials included material-air partitioning coefficients (Kma) for chlorinated solvents, sampler equilibration time and field suitability. The materials investigated were polydimethylsiloxane (PDMS), low-density polyethylene (LDPE), linear low-density polyethylene (LLDPE), polyoxymethylene (POM) and plasticized polyvinyl chloride (PVC). Both PDMS and LLDPE samplers demonstrated high partitioning coefficients and diffusivities and were further tested in greenhouse experiments and field trials. While most of the materials could be used for passive sampling, the PDMS SPSs performed best as an in planta sampler. Such a sampler was able to accurately measure trichloroethylene (TCE) and tetrachloroethylene (PCE) concentrations while simultaneously incorporating simple operation and minimal impact to the surrounding property and environment. Copyright © 2013 Elsevier Ltd. All rights reserved.
Alkyl Chain Ordering of Asymmetric Phosphatidyicholines Adsorbed at a Liquid-Liquid Interface
1998-05-30
the blood bind to the PL surface and begin to hydrolyze the triglyceride core and only a small fraction of the phospholipids, such that the core...which surface-adsorbed proteins are able to hydrolyze the triglyceride core has been shown to depend on the acyl chain composition of monolayer PCs...in the commercial use of natural phosphatidylcholines (or lecithins ) as emulsifiers, including their use in delivery of water-insoluble drugs (Davis
Dziedzic, K S; Healey, E L; Porcheret, M; Afolabi, E K; Lewis, M; Morden, A; Jinks, C; McHugh, G A; Ryan, S; Finney, A; Main, C; Edwards, J J; Paskins, Z; Pushpa-Rajah, A; Hay, E M
2018-01-01
To determine the effectiveness of a model osteoarthritis consultation, compared with usual care, on physical function and uptake of National Institute for Health and Care Excellence (NICE) osteoarthritis recommendations, in adults ≥45 years consulting with peripheral joint pain in UK general practice. Two-arm cluster-randomised controlled trial with baseline health survey. Eight general practices in England. 525 adults ≥45 years consulting for peripheral joint pain, amongst 28,443 population survey recipients. Four intervention practices delivered the model osteoarthritis consultation to patients consulting with peripheral joint pain; four control practices continued usual care. The primary clinical outcome of the trial was the SF-12 physical component score (PCS) at 6 months; the main secondary outcome was uptake of NICE core recommendations by 6 months, measured by osteoarthritis quality indicators. A Linear Mixed Model was used to analyse clinical outcome data (SF-12 PCS). Differences in quality indicator outcomes were assessed using logistic regression. 525 eligible participants were enrolled (mean age 67.3 years, SD 10.5; 59.6% female): 288 from intervention and 237 from control practices. There were no statistically significant differences in SF-12 PCS: mean difference at the 6-month primary endpoint was -0.37 (95% CI -2.32, 1.57). Uptake of core NICE recommendations by 6 months was statistically significantly higher in the intervention arm compared with control: e.g., increased written exercise information, 20.5% (7.9, 28.3). Whilst uptake of core NICE recommendations was increased, there was no evidence of benefit of this intervention, as delivered in this pragmatic randomised trial, on the primary outcome of physical functioning at 6 months. ISRCTN06984617. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
USDA-ARS?s Scientific Manuscript database
The objective of this simulation study is to determine which sampling method (Cozzini core sampler, core drill shaving, and N-60 surface excision) will better detect Shiga Toxin-producing Escherichia coli (STEC) at varying levels of contamination when present in the meat. 1000 simulated experiments...
NASA Astrophysics Data System (ADS)
Bent, J. D.; Sweeney, C.; Tans, P. P.; Newberger, T.; Higgs, J. A.; Wolter, S.
2017-12-01
Accurate estimates of point source gas emissions are essential for reconciling top-down and bottom-up greenhouse gas measurements, but sampling such sources is challenging. Remote sensing methods are limited by resolution and cloud cover; aircraft methods are limited by air traffic control clearances, and the need to properly determine boundary layer height. A new sampling approach leverages the ability of unmanned aerial systems (UAS) to measure all the way to the surface near the source of emissions, improving sample resolution, and reducing the need to characterize a wide downstream swath, or measure to the full height of the planetary boundary layer (PBL). The "Active-AirCore" sampler, currently under development, will fly on a fixed wing UAS in Class G airspace, spiraling from the surface to 1200 ft AGL around point sources such as leaking oil wells to measure methane, carbon dioxide and carbon monoxide. The sampler collects a 100-meter long sample "core" of air in an 1/8" passivated stainless steel tube. This "core" is run on a high-precision instrument shortly after the UAS is recovered. Sample values are mapped to a specific geographic location by cross-referencing GPS and flow/pressure metadata, and fluxes are quantified by applying Gauss's theorem to the data, mapped onto the spatial "cylinder" circumscribed by the UAS. The AirCore-Active builds off the sampling ability and analytical approach of the related AirCore sampler, which profiles the atmosphere passively using a balloon launch platform, but will add an active pumping capability needed for near-surface horizontal sampling applications. Here, we show design elements, laboratory and field test results for methane, describe the overall goals of the mission, and discuss how the platform can be adapted, with minimal effort, to measure other gas species.
Piotrow, P T; Coleman, P L
1992-03-01
This article describes how the Population Communication Services (PCS) has seized on the "enter-educate" approach, the blending of popular entertainment with social messages, to change reproductive health behavior. The enter-educate approach spreads its message through songs, soap operas, variety shows, and other types of popular entertainment mediums. Because they entertain, enter-educate projects can capture the attention of an audience -- such as young people -- who would otherwise scorn social messages. And the use of population mediums makes it possible to reach a variety of audiences. Funded by USAID, PCS began its first enter-educate project in response to the increasing number of teenage pregnancies in Latin America. PCS developed 2 songs and videos, which featured popular teenage singers to serve as role models, to urge abstinence. The songs became instant hits. Since then, PCS has mounted more then 80 major projects in some 40 countries. Highlights of programs range from a successful multi-media family planning campaign in Turkey to humorous television ads in Brazil promoting vasectomy. Recently, PCS initiated projects to teach AIDS awareness. At the core of the enter-educate approach is the social learning theory which holds that much behavior is learned through the observation of role-models. Health professionals work alongside entertainers to produce works that have audience appeal and factual social messages. The enter-educate approach works because it is popular, pervasive, personal, persuasive, and profitable. PCS has found that enter-educate programs pay for themselves through cost sharing and cost recovery.
Simon, N.S.; Kennedy, M.M.; Massoni, C.S.
1985-01-01
Field and laboratory evaluations were made of a simple, inexpensive diffusion-controlled sampler with ports on two sides at each interval which incorporates 0.2-??m polycarbonate membrane to filter samples in situ. Monovalent and divalent ions reached 90% of equilibrium between sampler contents and the external solution within 3 and 6 hours, respectively. Sediment interstitial water chemical gradients to depths of tens of centimeters were obtained within several days after placement. Gradients were consistent with those determined from interstitial water obtained by centrifugation of adjacent sediment. Ten milliliter sample volumes were collected at 1-cm intervals to determine chemical gradients and dissolved oxygen profiles at depth and at the interface between the sediment and water column. The flux of dissolved species, including oxygen, across the sediment-water interface can be assessed more accurately using this sampler than by using data collected from benthic cores. ?? 1985 Dr W. Junk Publishers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... proposed location and purpose of the activities, including: (1) Gravity and magneto-metric measurements; (2...) Sediment sampling of a limited nature using either core or grab samplers, and the specified diameter and...) Hydrographic and oceanographic measurements, including the setting of instruments; and (7) Small diameter core...
Code of Federal Regulations, 2011 CFR
2011-07-01
... proposed location and purpose of the activities, including: (1) Gravity and magneto-metric measurements; (2...) Sediment sampling of a limited nature using either core or grab samplers, and the specified diameter and...) Hydrographic and oceanographic measurements, including the setting of instruments; and (7) Small diameter core...
Proceedings of the wellbore sampling workshop
DOE Office of Scientific and Technical Information (OSTI.GOV)
Traeger, R.K.; Harding, B.W.
Representatives from academia, industry and research laboratories participated in an intensive two-day review to identify major technological limitations in obtaining solid and fluid samples from wellbores. Top priorities identified for further development include: coring of hard and unconsolidated materials; flow through fluid samplers with borehole measurements T, P and pH; and nonintrusive interrogation of pressure cores.
Chung, K Y; Carter, G J; Stancliffe, J D
1999-02-01
A new European/International Standard (ISOprEN 10882-1) on the sampling of airborne particulates generated during welding and allied processes has been proposed. The use of a number of samplers and sampling procedures is allowable within the defined protocol. The influence of these variables on welding fume exposures measured during welding and grinding of stainless and mild steel using the gas metal arc (GMA) and flux-cored arc (FCA) and GMA welding of aluminium has been examined. Results show that use of any of the samplers will not give significantly different measured exposures. The effect on exposure measurement of placing the samplers on either side of the head was variable; consequently, sampling position cannot be meaningfully defined. All samplers collected significant amounts of grinding dust. Therefore, gravimetric determination of welding fume exposure in atmospheres containing grinding dust will be inaccurate. The use of a new size selective sampler can, to some extent, be used to give a more accurate estimate of exposure. The reliability of fume analysis data of welding consumables has caused concern; and the reason for differences that existed between the material safety data sheet and the analysis of fume samples collected requires further investigation.
30 CFR 280.30 - What activities will not require environmental analysis?
Code of Federal Regulations, 2010 CFR
2010-07-01
... types of activities include: (a) Gravity and magnetometric observations and measurements; (b) Bottom and..., including the setting of instruments; (g) Sampling by box core or grab sampler to determine seabed...
Fenton, Susan H; Benigni, Mary Sue
2014-01-01
The transition from ICD-9-CM to ICD-10-CM/PCS is expected to result in longitudinal data discontinuities, as occurred with cause-of-death in 1999. The General Equivalence Maps (GEMs), while useful for suggesting potential maps do not provide guidance regarding the frequency of any matches. Longitudinal data comparisons can only be reliable if they use comparability ratios or factors which have been calculated using records coded in both classification systems. This study utilized 3,969 de-identified dually coded records to examine raw comparability ratios, as well as the comparability ratios between the Joint Commission Core Measures. The raw comparability factor results range from 16.216 for Nicotine dependence, unspecified, uncomplicated to 118.009 for Chronic obstructive pulmonary disease, unspecified. The Joint Commission Core Measure comparability factor results range from 27.15 for Acute Respiratory Failure to 130.16 for Acute Myocardial Infarction. These results indicate significant differences in comparability between ICD-9-CM and ICD-10-CM code assignment, including when the codes are used for external reporting such as the Joint Commission Core Measures. To prevent errors in decision-making and reporting, all stakeholders relying on longitudinal data for measure reporting and other purposes should investigate the impact of the conversion on their data.
Use of Vibratory Coring Samplers for Sediment Surveys.
1981-07-01
PAGE ( Man Data R,10#0d,REPORT~~EA INST".T0.P0E’RUCTIONS REPORT DOCUMENTATION PAGE BEFORE COMPLETING FORM I. REPORT NUMBER 2. GOVT ACCESSION NO. 3...COR COARSE 3BRYOZOA S ND AND LARGE SUAND ANSHELS _ CALCAREOUS SANDSTONE ELTH SHELL b CALCAREOUS SANDSTONE PEBBLES SM AND SHELLSb CASTS AND ABUNDAT...GLAUCONITE FINE ANY LMESTOE WITH S SNELL CASTS AND ABUNDANT GLAUCONlITE 1o 4 15-2 5 206 CORE 34 CORE 3S CORE 36 0 D 48 WO 49 WD 26 jFINE SHELF FACIES
A tubular-coring device for use in biogeochemical sampling of succulent and pulpy plants
Campbell, W.L.
1986-01-01
A hand-operated, tubular-coring device developed for use in biogeochemical sampling of succulent and pulpy plants is described. The sampler weighs about 500 g (1.1 lb); and if 25 ?? 175 mm (1 ?? 7 in) screw-top test tubes are used as sample containers, the complete sampling equipment kit is easily portable, having both moderate bulk and weight. ?? 1986.
OPSAID Initial Design and Testing Report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hurd, Steven A.; Stamp, Jason Edwin; Chavez, Adrian R.
2007-11-01
Process Control System (PCS) security is critical to our national security. Yet, there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy's Office of Electricity Delivery and Reliability, aims to address this issue through developing and testing an open source architecture for PCS security. Sandia National Laboratories, along with a team of PCS vendors and owners, have developed and tested this PCS security architecture. This report describes their progress to date.2 AcknowledgementsThe authors acknowledgemore » and thank their colleagues for their assistance with the OPSAID project.Sandia National Laboratories: Alex Berry, Charles Perine, Regis Cassidy, Bryan Richardson, Laurence PhillipsTeumim Technical, LLC: Dave TeumimIn addition, the authors are greatly indebted to the invaluable help of the members of the OPSAID Core Team. Their assistance has been critical to the success and industry acceptance of the OPSAID project.Schweitzer Engineering Laboratory: Rhett Smith, Ryan Bradetich, Dennis GammelTelTone: Ori Artman Entergy: Dave Norton, Leonard Chamberlin, Mark AllenThe authors would like to acknowledge that the work that produced the results presented in this paper was funded by the U.S. Department of Energy/Office of Electricity Delivery and Energy Reliability (DOE/OE) as part of the National SCADA Test Bed (NSTB) Program. Executive SummaryProcess control systems (PCS) are very important for critical infrastructure and manufacturing operations, yet cyber security technology in PCS is generally poor. The OPSAID (Open PCS (Process Control System) Security Architecture for Interoperable Design) program is intended to address these security shortcomings by accelerating the availability and deployment of comprehensive security technology for PCS, both for existing PCS and inherently secure PCS in the future. All activities are closely linked to industry outreach and advisory efforts.Generally speaking, the OPSAID project is focused on providing comprehensive security functionality to PCS that communicate using IP. This is done through creating an interoperable PCS security architecture and developing a reference implementation, which is tested extensively for performance and reliability.This report first provides background on the PCS security problem and OPSAID, followed by goals and objectives of the project. The report also includes an overview of the results, including the OPSAID architecture and testing activities, along with results from industry outreach activities. Conclusion and recommendation sections follow. Finally, a series of appendices provide more detailed information regarding architecture and testing activities.Summarizing the project results, the OPSAID architecture was defined, which includes modular security functionality and corresponding component modules. The reference implementation, which includes the collection of component modules, was tested extensively and proved to provide more than acceptable performance in a variety of test scenarios. The primary challenge in implementation and testing was correcting initial configuration errors.OPSAID industry outreach efforts were very successful. A small group of industry partners were extensively involved in both the design and testing of OPSAID. Conference presentations resulted in creating a larger group of potential industry partners.Based upon experience implementing and testing OPSAID, as well as through collecting industry feedback, the OPSAID project has done well and is well received. Recommendations for future work include further development of advanced functionality, refinement of interoperability guidance, additional laboratory and field testing, and industry outreach that includes PCS owner education. 4 5 --This page intentionally left blank --« less
Synthesis of phthalocyanine derivatives as materials for organic photovoltaic cells
NASA Astrophysics Data System (ADS)
Collazo-Ramos, Aura
Organic photovoltaics (OPVs) are used to convert sunlight into electricity by using thin films of organic semiconductors. OPVs have the potential to produce low cost, lightweight, flexible devices with an eased manufacturing process. This technology contains the potential to increase the use of clean, sustainable solar energy, helping manage the global energy and environmental crisis that results majorly from the constant use of fossil fuels as an energy source. The ability to modulate the physical properties of organic molecules by tuning their chemical structure is an advantage for OPVs. Phthalocyanines (Pcs) are highly pi-conjugated synthetic porphyrin analogs that have been explored as active layer components in OPVs due to their high extinction coefficients and hole mobilities. The Pc structure can be modified by the introduction of metals in the core and the incorporation of substituents into the periphery. These modifications tend to tune the solubility, photophysical properties and condensed phase organization of Pcs. The research work in this dissertation describes improved methods towards substituted Pc derivatives addressing: (1) the use of mass spectrometry techniques for Pcs characterization, (2) efforts to achieve materials with near-infrared (NIR) absorption, and (3) the potential of Pc as electron-acceptor materials. Herein, the synthesis of a series of asymmetric and symmetric metallated Pcs has been established, which resulted in interesting chemical, photophysical and electrochemical properties. The materials investigated in this thesis increase the potential of Pcs as organic semiconductors for OPVs.
Freeze shoe sampler for the collection of hyporheic zone sediments and porewater.
Bianchin, M; Smith, L; Beckie, R
2015-01-01
The Starr and Ingleton (1992) drive point piston sampler (DPPS) design was modified by fitting it with a Murphy and Herkelrath (1996) type sample-freezing drive shoe (SFDS), which uses liquid carbon dioxide as a cryogen. Liquid carbon dioxide was used to freeze sediments in the lower 0.1 m of the core and the drive-point piston sealed the core at the top preserving the reductive-oxidation (redox) sensitive sediments from the atmosphere and maintaining natural stratigraphy. The use of nitrogen gas to provide positive pressure on the gas system blocked the ingress of water which froze on contact with the cryogen thus blocking the gas lines with ice. With this adaptation to the gas system cores could be collected at greater depths beneath the static water level. This tool was used to collect intact saturated sediment cores from the hyporheic zone of the tidally influenced Fraser River in Vancouver, British Columbia, Canada where steep geochemical and microbial gradients develop within the interface between discharging anaerobic groundwater and recharging aerobic river water. In total, 25 cores driven through a 1.5 m sampling interval were collected from the river bed with a mean core recovery of 75%. The ability to deploy this method from a fishing vessel makes the tool more cost effective than traditional marine-based drilling operations which often use barges, tug boats, and drilling rigs. © 2014, National Ground Water Association.
Building a Better Biology Lab? Testing Tablet PC Technology in a Core Laboratory Course
ERIC Educational Resources Information Center
Pryor, Gregory; Bauer, Vernon
2008-01-01
Tablet PC technology can enliven the classroom environment because it is dynamic, interactive, and "organic," relative to the rigidity of chalkboards, whiteboards, overhead projectors, and PowerPoint presentations. Unlike traditional computers, tablet PCs employ "digital linking," allowing instructors and students to freehand annotate, clarify,…
Inexpensive, easy-to-construct suction coring devices usable from small boats
Onuf, Christopher P.; Chapman, Duane C.; Rizzo, William M.
1996-01-01
Collection of sediment cores in depths of 1-5 m is difficult with traditional sampling gear. Here we describe three suction coring devices constructed with readily available plumbing supplies and parts easily made from acrylic plastic and silicone sealant. The samplers have been used successfully in sediments ranging from coarse sands and shell hash to muds, highly organic deposits, and dense clays. Successful applications have ranged from contaminants analysis, toxicity testing, seagrass mapping, and assessment of sediment-microfloral interactions to sampling the infauna of surf-swept beaches.
MetAlign 3.0: performance enhancement by efficient use of advances in computer hardware.
Lommen, Arjen; Kools, Harrie J
2012-08-01
A new, multi-threaded version of the GC-MS and LC-MS data processing software, metAlign, has been developed which is able to utilize multiple cores on one PC. This new version was tested using three different multi-core PCs with different operating systems. The performance of noise reduction, baseline correction and peak-picking was 8-19 fold faster compared to the previous version on a single core machine from 2008. The alignment was 5-10 fold faster. Factors influencing the performance enhancement are discussed. Our observations show that performance scales with the increase in processor core numbers we currently see in consumer PC hardware development.
An improved technique for taking hydraulic conductivity cores from forest soils
Gerald M. Aubertin
1969-01-01
Describes a large-diameter, heavy-duty soil sampler that makes it possible to obtain long, relatively undisturbed sample columns from stony, root-filled forest soils. The resultant samples include the roots, root channels, stones, and macro-voids common to forested soils.
Field studies in architectural acoustics using Tablet PCs
NASA Astrophysics Data System (ADS)
Boye, Daniel
2005-04-01
Core requirements for the sciences within the liberal arts curriculum challenge students to become directly involved in scientific study. These requirements seek to develop scientifically literate leaders and members of society. Formal laboratory periods are not usually associated with these courses. Thus, conceptual discovery and quantitative experimentation must take place outside of the classroom. Physics 115: Musical Technology at Davidson College is such a course and contains a section dealing with architectural acoustics. Field studies in the past have been an awkward and cumbersome activity, especially for non-science majors. The emerging technology of Tablet PCs overcomes many of the problems of mobile data acquisition and analysis, and allows the students to determine the locations of the rooms to be studied. The impulse method for determining reverberation time is used and compared with calculations based on room size and absorption media. The use of Tablet PCs and the publicly available freeware Audacity in field studies investigating architectural acoustics will be discussed. [Work supported in part by the Associated Colleges of the South through their Technology Fellowship program.
Bloem, E; Hogervorst, F A N; de Rooij, G H
2009-04-01
Solutes spread out in time and space as they move downwards from the soil surface with infiltrating water. Solute monitoring in the field is often limited to observations of resident concentrations, while flux concentrations govern the movement of solutes in soils. A recently developed multi-compartment sampler is capable of measuring fluxes at a high spatial resolution with minimal disturbance of the local pressure head field. The objective of this paper is to use this sampler to quantify the spatial and temporal variation of solute leaching below the root zone in an agricultural field under natural rainfall in winter and spring. We placed two samplers at 31 and 25 cm depth in an agricultural field, leaving the soil above undisturbed. Each sampler contained 100 separate cells of 31x31 mm. Water fluxes were measured every 5 min for each cell. We monitored leaching of a chloride pulse under natural rainfall by frequently extracting the collected leachate while leaving the samplers buried in situ. This experiment was followed by a dye tracer experiment. This setting yielded information that widely surpassed the information that can be provided by separate anionic and dye tracer trials, and solute transport monitoring by coring or suction cups. The detailed information provided by the samplers showed that percolation at the sampling depth started much faster (approximately 3 h after the start of rainfall) in initially wet soil (pressure head above -65 cm) than in drier soil (more than 14 h at pressure heads below -80 cm). At any time, 25% of the drainage passed through 5-6% of the sampled area, reflecting the effect of heterogeneity on the flow paths. The amount of solute carried by individual cells varied over four orders of magnitude. The lateral concentration differences were limited though. This suggests a convective-dispersive regime despite the short vertical travel distance. On the other hand, the dilution index indicates a slight tendency towards stochastic-convective transport at this depth. There was no evidence in the observed drainage patterns and dye stained profiles of significant disturbance of the flow field by the samplers.
Clarendon Alternative School Japanese Bilingual Bicultural Program: Curriculum Sampler.
ERIC Educational Resources Information Center
San Francisco Unified School District, CA.
Sample lessons and instructional materials from a Japanese bilingual/bicultural elementary school program are presented. The lessons are designed to integrate Japanese language instruction with content instruction, using thematic units related to the core curriculum. The ten lessons are organized by target grade (K-5), and describe classroom…
Kenzik, Kelly M; Ganz, Patricia A; Martin, Michelle Y; Petersen, Laura; Hays, Ron D; Arora, Neeraj; Pisu, Maria
2015-08-15
The objective of this study was to examine associations of symptoms with physical and mental health-related quality of life (HRQOL) in patients with colorectal cancer (CRC) and in patients with lung cancer. Patients with newly diagnosed CRC (n = 3040) or lung cancer (n = 2297) who were participating in the Cancer Care Outcomes Research and Surveillance Consortium study completed surveys on general HRQOL and symptoms. HRQOL was measured by using physical component summary (PCS) and mental component summary (MCS) scores on the Medical Outcomes Study 12-item short-form heath survey. Nonspecific cancer symptoms were measured using items from the European Organization for Research and Treatment of Cancer core quality-of-life questionnaire. Cancer type-specific modules developed by the European Organization for Research and Treatment of Cancer were used to assess CRC-specific and lung cancer-specific symptoms. For both cancer types, linear regression models that were controlled for demographic and clinical information were used to examine correlations of nonspecific and cancer-specific symptoms with PCS and MCS scores. PCS scores for patients with CRC and lung cancer were below the general population norm of 50 (43 and 37, respectively), and MCS scores were at the population norm. For the CRC sample, in the model that included both symptom indices, an increase in nonspecific symptoms was more strongly associated with lower PCS and MCS scores than an increase in CRC-specific symptoms (PCS, standardized coefficient [β] = -0.41 vs -0.09; MCS, β = -0.38 vs -0.08). In a similar model for lung cancer, increases in lung cancer-specific symptoms were more strongly associated with lower PCS scores (β = -0.34 vs -0.20), whereas nonspecific symptoms were more strongly associated with lower MCS scores (β = -0.34 vs -0.14). Symptoms were associated with HRQOL impairments in recently diagnosed patients. Additional supportive care implemented early in cancer care, regardless of cancer stage, may provide symptom relief and improve HRQOL. © 2015 American Cancer Society.
NASA Technical Reports Server (NTRS)
Bar-Cohen, Yoseph; Badescu, Mircea; Sherrit, Stewart; Zacny, Kris; Paulsen, Gale L; Beegle, Luther; Bao, Xiaoqi
2012-01-01
The ability to penetrate subsurfaces and perform sample acquisition at depths of meters is critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of acquiring pristine samples by reaching depths on Mars beyond the oxidized and sterilized zone. To developed rotary-hammering coring drill, called Auto-Gopher, employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that is incorporated with an inchworm mechanism allowing thru cyclic coring and core removal to reach great depths. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The Auto-Gopher has been produced taking into account the a lessons learned from the development of the Ultrasonic/Sonic Gopher that was designed as a percussive ice drill and was demonstrated in Antarctica in 2005 to reach about 2 meters deep. A field demonstration of the Auto-Gopher is currently being planned with objective of reaching as deep as 3 to 5 meters in tufa subsurface.
Li, An-Ming; Yu, Bing-Yun; Chen, Fu-Hua; Gan, Hui-Yan; Yuan, Jian-Gang; Qiu, Rongliang; Huang, Jun-Chao; Yang, Zhong-Yi; Xu, Zeng-Fu
2009-01-01
Phytochelatins (PCs) play an important role in detoxification of heavy metals in plants. PCs are synthesized from glutathione by phytochelatin synthase (PCS), a dipeptidyltransferase. Sesbania rostrata is a tropical legume plant that can tolerate high concentrations of Cd and Zn. In this study, the S. rostrata PCS gene (SrPCS) and cDNAs were isolated and characterized. Southern blot and sequence analysis revealed that a single copy of the SrPCS gene occurs in the S. rostrata genome, and produces four different SrPCS mRNAs and proteins, SrPCS1–SrPCS4, by alternative splicing of the SrPCS pre-mRNA. The SrPCS1 and SrPCS3 proteins conferred Cd tolerance when expressed in yeast cells, whereas the SrPCS2 and SrPCS4 proteins, which lack the catalytic triad and the N-terminal domains, did not. These results suggested that SrPCS1 and SrPCS3 have potential applications in genetic engineering of plants for enhancing heavy metal tolerance and phytoremediation of contaminated soils. PMID:20111680
Li, An-Ming; Yu, Bing-Yun; Chen, Fu-Hua; Gan, Hui-Yan; Yuan, Jian-Gang; Qiu, Rongliang; Huang, Jun-Chao; Yang, Zhong-Yi; Xu, Zeng-Fu
2009-07-24
Phytochelatins (PCs) play an important role in detoxification of heavy metals in plants. PCs are synthesized from glutathione by phytochelatin synthase (PCS), a dipeptidyltransferase. Sesbania rostrata is a tropical legume plant that can tolerate high concentrations of Cd and Zn. In this study, the S. rostrata PCS gene (SrPCS) and cDNAs were isolated and characterized. Southern blot and sequence analysis revealed that a single copy of the SrPCS gene occurs in the S. rostrata genome, and produces four different SrPCS mRNAs and proteins, SrPCS1-SrPCS4, by alternative splicing of the SrPCS pre-mRNA. The SrPCS1 and SrPCS3 proteins conferred Cd tolerance when expressed in yeast cells, whereas the SrPCS2 and SrPCS4 proteins, which lack the catalytic triad and the N-terminal domains, did not. These results suggested that SrPCS1 and SrPCS3 have potential applications in genetic engineering of plants for enhancing heavy metal tolerance and phytoremediation of contaminated soils.
NASA Astrophysics Data System (ADS)
Gilhooly, W. P.; Macko, S. A.; Flemings, P. B.
2005-12-01
Pleistocene and Recent sediments within the Brazos-Trinity and Ursa Basins (northwestern Gulf of Mexico) were largely deposited by turbidity currents and have been deformed by a number of mass transport events. The geochemical composition of interstitial waters was determined in order to assess fluid flow within these sediments. Typical porewater sampling resolution, using advanced piston coring and the traditional Manheim squeezer technique, is approximately one sample every other core (20m) with the highest working resolution at one sample every 1.5m. In this study, Rhizon soil moisture samplers were used to attain high-resolution porewater profiles within sea floor surface sediments and for permeable sediments at depth. The small dimensions (2mm x 30mm) and pore-size (1μm) of the devices enable high-frequency placement within a core, specific targeting of the sequence of interest, and do not require sediment removal from the core, or filtering of extracted porewaters. Initial shipboard analyses derived from sediments at the Ursa Basin (Site 1322) indicate a linear decrease in salinity with depth at U1322 where the overpressure gradient is thought to be greatest. The less saline waters with depth lends evidence for potential mixing between deep-seated fluids and low salinity ones derived from the Blue Unit and seawater. Isotopic composition and concentrations of sulfur species (SO4 and H2S) dissolved in porewaters, as well as, ionic compositions (Cl, Na, K, Ca, Mg) and chemical composition of associated sediments (%C, %N, 13C, and 15N) are compared with chemical results obtained with squeezers.
Barnier, C; Palmier, C; Atteia, O
2013-01-01
The vertical heterogeneity of contaminant concentrations in aquifers is well known, but obtaining representative samples is still a subject of debate. In this paper, the question arises from sites where numerous fully screened wells exist and there is a need to define the vertical distribution of contaminants. For this purpose, several wells were investigated with different techniques on a site contaminated with chlorinated solvents. A core-bored well shows that a tetrachloroethene (PCE) phase is sitting on and infiltrating a less permeable layer. Downstream of the cored well, the following sampling techniques were compared on fully screened wells: low flow pumping at several depths, pumping between packers and a new multilevel sampler for fully screened wells. Concerning low flow rate pumping, very low gradients were found, which may be due to the existence of vertical flow inside the well or in the gravel pack. Sampling between packers gave results comparable with the cores, separating a layer with PCE and trichloroethene from another one with cis 1,2-dichloroethene and vinyl chloride as major compounds. Detailed sampling according to pumped volume shows that even between packers, cleaning of the inter-packer volume is necessary before each sampling. Lastly, the proposed new multilevel sampler gives results similar to the packers but has the advantages of much faster sampling and a constant vertical positioning, which is fairly important for long-term monitoring in highly stratified aquifers.
Precision, accuracy, and efficiency of four tools for measuring soil bulk density or strength.
Richard E. Miller; John Hazard; Steven Howes
2001-01-01
Monitoring soil compaction is time consuming. A desire for speed and lower costs, however, must be balanced with the appropriate precision and accuracy required of the monitoring task. We compared three core samplers and a cone penetrometer for measuring soil compaction after clearcut harvest on a stone-free and a stony soil. Precision (i.e., consistency) of each tool...
Loscos, Jorge; Naya, Loreto; Ramos, Javier; Clemente, Maria R; Matamoros, Manuel A; Becana, Manuel
2006-04-01
Phytochelatin synthases (PCS) catalyze phytochelatin (PC) synthesis from glutathione (GSH) in the presence of certain metals. The resulting PC-metal complexes are transported into the vacuole, avoiding toxic effects on metabolism. Legumes have the unique capacity to partially or completely replace GSH by homoglutathione (hGSH) and PCs by homophytochelatins (hPCs). However, the synthesis of hPCs has received little attention. A search for PCS genes in the model legume Lotus (Lotus japonicus) resulted in the isolation of a cDNA clone encoding a protein (LjPCS1) highly homologous to a previously reported homophytochelatin synthase (hPCS) of Glycine max (GmhPCS1). Recombinant LjPCS1 and Arabidopsis (Arabidopsis thaliana) PCS1 (AtPCS1) were affinity purified and their polyhistidine-tags removed. AtPCS1 catalyzed hPC synthesis from hGSH alone at even higher rates than did LjPCS1, indicating that GmhPCS1 is not a genuine hPCS and that a low ratio of hPC to PC synthesis is an inherent feature of PCS1 enzymes. For both enzymes, hGSH is a good acceptor, but a poor donor, of gamma-glutamylcysteine units. Purified AtPCS1 and LjPCS1 were activated (in decreasing order) by Cd2+, Zn2+, Cu2+, and Fe3+, but not by Co2+ or Ni2+, in the presence of 5 mm GSH and 50 microm metal ions. Activation of both enzymes by Fe3+ was proven by the complete inhibition of PC synthesis by the iron-specific chelator desferrioxamine. Plants of Arabidopsis and Lotus accumulated (h)PCs only in response to a large excess of Cu2+ and Zn2+, but to a much lower extent than did with Cd2+, indicating that (h)PC synthesis does not significantly contribute in vivo to copper, zinc, and iron detoxification.
Ramos, Javier; Clemente, Maria R; Naya, Loreto; Loscos, Jorge; Pérez-Rontomé, Carmen; Sato, Shusei; Tabata, Satoshi; Becana, Manuel
2007-03-01
The biosynthesis of phytochelatins and homophytochelatins has been studied in nodulated plants of the model legume Lotus (Lotus japonicus). In the first 6 to 24 h of treatment with cadmium (Cd), roots started to synthesize elevated amounts of both polypeptides, with a concomitant increase of glutathione and a decrease of homoglutathione, indicating the presence of active phytochelatin synthase (PCS) genes. Screening of transformation-competent artificial chromosome libraries allowed identification of a cluster of three genes, LjPCS1, LjPCS2, and LjPCS3, which were mapped at 69.0 cM on chromosome 1. The genes differ in exon-intron composition and responsiveness to Cd. Gene structures and phylogenetic analysis of the three protein products, LjPCS1-8R, LjPCS2-7N, and LjPCS3-7N, are consistent with two sequential gene duplication events during evolution of vascular plants. Two sites for alternative splicing in the primary transcripts were identified. One of them, involving intron 2 of the LjPCS2 gene, was confirmed by the finding of the two predicted mRNAs, encoding LjPCS2-7R in roots and LjPCS2-7N in nodules. The amino acid sequences of LjPCS2-7R (or LjPCS2-7N) and LjPCS3-7N share 90% identity, but have only 43% to 59% identity with respect to the typical PCS1 enzymes of Lotus and other plants. The unusual LjPCS2-7N and LjPCS3-7N proteins conferred Cd tolerance when expressed in yeast (Saccharomyces cerevisiae) cells, whereas the alternatively spliced form, LjPCS2-7R, differing only in a five-amino acid motif (GRKWK) did not. These results unveil complex regulatory mechanisms of PCS expression in legume tissues in response to heavy metals and probably to other developmental and environmental factors.
NASA Astrophysics Data System (ADS)
Barnhart, E. P.; Ruppert, L. F.; Orem, W. H.; McIntosh, J. C.; Cunningham, A. B.; Fields, M. W.; Hiebert, R.; Hyatt, R.
2016-12-01
There is an increasing threat that deep aquifers, an important drinking water resource, may be contaminated by the extraction and transport of fossil fuels. This threat increases the need for improved groundwater monitoring and the ability to predict the extent to which microbial activity may remediate such contamination. The characterization of subsurface microbial communities could provide an ideal biomonitoring tool for the assessment of subsurface contamination due to prokaryotes environmental ubiquity, rapidity of response to environmental perturbation and the important role they play in hydrocarbon degradation and bioremediation. New DNA sequencing technologies provide the opportunity to cost-effectively identify the vast subsurface microbial ecosystem, but use of this new technology is restricted due to issues with sampling. Prior subsurface microbiology studies have relied on core samples that are expensive to obtain hard to collect aseptically and/or ground water samples that do not reflect in situ microbial densities or activities. The development of down-well incubation of sterile sediment with a Diffusive Microbial Sampler (DMS) has emerged as an alternative method to sample subsurface microbial communities that minimizes cost and contamination issues associated with traditional methods. We have designed a Subsurface Environment Sampler with a DMS module that could enable the anaerobic transport of the in situ microbial community from the field for laboratory bioremediation studies. This sampler could provide an inexpensive and standard method for subsurface microbial sampling which would make this tool useful for Federal, State, private and local agencies interested in monitoring contamination or the effectiveness of bioremediation activities in subsurface aquifers.
Cena, L G; Chisholm, W P; Keane, M J; Chen, B T
2015-01-01
A field study was conducted to estimate the amount of Cr, Mn, and Ni deposited in the respiratory system of 44 welders in two facilities. Each worker wore a nanoparticle respiratory deposition (NRD) sampler during gas metal arc welding (GMAW) of mild and stainless steel and flux-cored arc welding (FCAW) of mild steel. Several welders also wore side-by-side NRD samplers and closed-face filter cassettes for total particulate samples. The NRD sampler estimates the aerosol's nano-fraction deposited in the respiratory system. Mn concentrations for both welding processes ranged 2.8-199 μg/m3; Ni concentrations ranged 10-51 μg/m3; and Cr concentrations ranged 40-105 μg/m3. Cr(VI) concentrations ranged between 0.5-1.3 μg/m3. For the FCAW process the largest concentrations were reported for welders working in pairs. As a consequence this often resulted in workers being exposed to their own welding fumes and to those generated from the welding partner. Overall no correlation was found between air velocity and exposure (R2 = 0.002). The estimated percentage of the nano-fraction of Mn deposited in a mild-steel-welder's respiratory system ranged between 10 and 56%. For stainless steel welding, the NRD samplers collected 59% of the total Mn, 90% of the total Cr, and 64% of the total Ni. These results indicate that most of the Cr and more than half of the Ni and Mn in the fumes were in the fraction smaller than 300 nm.
Critical pressure and multiphase flow in Blake Ridge gas hydrates
Flemings, P.B.; Liu, Xiuying; Winters, W.J.
2003-01-01
We use core porosity, consolidation experiments, pressure core sampler data, and capillary pressure measurements to predict water pressures that are 70% of the lithostatic stress, and gas pressures that equal the lithostatic stress beneath the methane hydrate layer at Ocean Drilling Program Site 997, Blake Ridge, offshore North Carolina. A 29-m-thick interconnected free-gas column is trapped beneath the low-permeability hydrate layer. We propose that lithostatic gas pressure is dilating fractures and gas is migrating through the methane hydrate layer. Overpressured gas and water within methane hydrate reservoirs limit the amount of free gas trapped and may rapidly export methane to the seafloor.
Process control systems: integrated for future process technologies
NASA Astrophysics Data System (ADS)
Botros, Youssry; Hajj, Hazem M.
2003-06-01
Process Control Systems (PCS) are becoming more crucial to the success of Integrated Circuit makers due to their direct impact on product quality, cost, and Fab output. The primary objective of PCS is to minimize variability by detecting and correcting non optimal performance. Current PCS implementations are considered disparate, where each PCS application is designed, deployed and supported separately. Each implementation targets a specific area of control such as equipment performance, wafer manufacturing, and process health monitoring. With Intel entering the nanometer technology era, tighter process specifications are required for higher yields and lower cost. This requires areas of control to be tightly coupled and integrated to achieve the optimal performance. This requirement can be achieved via consistent design and deployment of the integrated PCS. PCS integration will result in several benefits such as leveraging commonalities, avoiding redundancy, and facilitating sharing between implementations. This paper will address PCS implementations and focus on benefits and requirements of the integrated PCS. Intel integrated PCS Architecture will be then presented and its components will be briefly discussed. Finally, industry direction and efforts to standardize PCS interfaces that enable PCS integration will be presented.
NASA Astrophysics Data System (ADS)
Cong, Ming; Zhao, Jianmin; Lü, Jiasen; Ren, Zhiming; Wu, Huifeng
2016-09-01
The halophyte Suaeda salsa can grow in heavy metal-polluted areas along intertidal zones having high salinity. Since phytochelatins can eff ectively chelate heavy metals, it was hypothesized that S. salsa possessed a phytochelatin synthase (PCS) gene. In the present study, the cDNA of PCS was obtained from S. salsa (designated as SsPCS) using homologous cloning and the rapid amplification of cDNA ends (RACE). A sequence analysis revealed that SsPCS consisted of 1 916 bp nucleotides, encoding a polypeptide of 492 amino acids with one phytochelatin domain and one phytochelatin C domain. A similarity analysis suggested that SsPCS shared up to a 58.6% identity with other PCS proteins and clustered with PCS proteins from eudicots. There was a new kind of metal ion sensor motif in its C-terminal domain. The SsPCS transcript was more highly expressed in elongated and fibered roots and stems ( P<0.05) than in leaves. Lead and mercury exposure significantly enhanced the mRNA expression of SsPCS ( P<0.05). To the best of our knowledge, SsPCS is the second PCS gene cloned from a halophyte, and it might contain a diff erent metal sensing capability than the first PCS from Thellungiella halophila. This study provided a new view of halophyte PCS genes in heavy metal tolerance.
Benthic macrofauna data for San Francisco Bay, California, September 1986
Schemel, Laurence E.; Thompson, J.K.; Harmon, J.G.; Yost, B.T.
1995-01-01
Benthic macrofauna were collected during September 1986 to evaluate locations for long-term monitoring stations as part of the U.S. Geological Survey Regional Effects Monitoring Program in San Francisco Bay, California. Three to ten replicate samples were collected with a modified Van Veen sampler (0.05 m2 area) at ten locations. One box core sample (0.06 m2 area) was collected at seven to the ten locations. Six of the box core samples were split into an upper 10 cm sample and a deeper sample before analysis. Macrofauna specimens were identified to the lowest possible taxon, usually genus and species, then counted. An average of 88 percent of the benthic macrofauna specimens were identified to the species level. The fraction identified varied among stations from 54 to 98 percent. Nematodes and oligochaetes accounted for most of the unidentified specimens. Relative to the total number of species identified in five replicates at each location, an average of 90 percent of the species were collected with three replicates. In general, species with high to moderate abundances were present in all replicates, and species collected only after three or more replicates averaged less than one specimen per replicate. Results from the box cores showed that the dominant species were most abundant in the upper 10 cm, the depth of sediment that can be adequately sampled with a modified Van Veen sampler. On the basis of the number of species and their abundances at each location, seven of the ten locations were selected for sampling in the regular program, which began in March 1987.
Nakagomi, Takayuki; Kubo, Shuji; Nakano-Doi, Akiko; Sakuma, Rika; Lu, Shan; Narita, Aya; Kawahara, Maiko; Taguchi, Akihiko; Matsuyama, Tomohiro
2015-06-01
Brain vascular pericytes (PCs) are a key component of the blood-brain barrier (BBB)/neurovascular unit, along with neural and endothelial cells. Besides their crucial role in maintaining the BBB, increasing evidence shows that PCs have multipotential stem cell activity. However, their multipotency has not been considered in the pathological brain, such as after an ischemic stroke. Here, we examined whether brain vascular PCs following ischemia (iPCs) have multipotential stem cell activity and differentiate into neural and vascular lineage cells to reconstruct the BBB/neurovascular unit. Using PCs extracted from ischemic regions (iPCs) from mouse brains and human brain PCs cultured under oxygen/glucose deprivation, we show that PCs developed stemness presumably through reprogramming. The iPCs revealed a complex phenotype of angioblasts, in addition to their original mesenchymal properties, and multidifferentiated into cells from both a neural and vascular lineage. These data indicate that under ischemic/hypoxic conditions, PCs can acquire multipotential stem cell activity and can differentiate into major components of the BBB/neurovascular unit. Thus, these findings support the novel concept that iPCs can contribute to both neurogenesis and vasculogenesis at the site of brain injuries. © 2015 AlphaMed Press.
Cena, L. G.; Chisholm, W. P.; Keane, M. J.; Chen, B. T.
2016-01-01
A field study was conducted to estimate the amount of Cr, Mn, and Ni deposited in the respiratory system of 44 welders in two facilities. Each worker wore a nanoparticle respiratory deposition (NRD) sampler during gas metal arc welding (GMAW) of mild and stainless steel and flux-cored arc welding (FCAW) of mild steel. Several welders also wore side-by-side NRD samplers and closed-face filter cassettes for total particulate samples. The NRD sampler estimates the aerosol's nano-fraction deposited in the respiratory system. Mn concentrations for both welding processes ranged 2.8–199 μg/m3; Ni concentrations ranged 10–51 μg/m3; and Cr concentrations ranged 40–105 μg/m3. Cr(VI) concentrations ranged between 0.5–1.3 μg/m3. For the FCAW process the largest concentrations were reported for welders working in pairs. As a consequence this often resulted in workers being exposed to their own welding fumes and to those generated from the welding partner. Overall no correlation was found between air velocity and exposure (R2 = 0.002). The estimated percentage of the nano-fraction of Mn deposited in a mild-steel-welder's respiratory system ranged between 10 and 56%. For stainless steel welding, the NRD samplers collected 59% of the total Mn, 90% of the total Cr, and 64% of the total Ni. These results indicate that most of the Cr and more than half of the Ni and Mn in the fumes were in the fraction smaller than 300 nm. PMID:25985454
What happens when pharmaceuticals meet colloids.
Xing, Yingna; Chen, Xijuan; Zhuang, Jie; Chen, Xin
2015-12-01
Pharmaceuticals (PCs) have been widely detected in natural environment due to agricultural application of reclaimed water, sludge and animal wastes. Their potential risks to various ecosystems and even to human health have caused great concern; however, little was known about their environmental behaviors. Colloids (such as clays, metal oxides, and particulate organics) are kind of substances that are active and widespread in the environment. When PCs meet colloids, their interaction may influence the fate, transport, and toxicity of PCs. This review summarizes the progress of studies on the role of colloids in mediating the environmental behaviors of PCs. Synthesized results showed that colloids can adsorb PCs mainly through ion exchange, complexation and non-electrostatic interactions. During this process the structure of colloids and the stability of PCs may be changed. The adsorbed PCs may have higher risks to induce antibiotic resistance; besides, their transport may also be altered considering they have great chance to move with colloids. Solution conditions (such as pH, ionic strength, and cations) could influence these interactions between PCs and colloids, as they can change the forms of PCs and alter the primary forces between PCs and colloids in the solution. It could be concluded that PCs in natural soils could bind with colloids and then co-transport during the processes of irrigation, leaching, and erosion. Therefore, colloid-PC interactions need to be understood for risk assessment of PCs and the best management practices of various ecosystems (such as agricultural and wetland systems).
Essig, Yona J.; Webb, Samuel M.; Stürzenbaum, Stephen R.
2016-02-19
Here, environmental metal pollution is a growing health risk to flora and fauna. It is therefore important to fully elucidate metal detoxification pathways. Phytochelatin synthase (PCS), an enzyme involved in the biosynthesis of phytochelatins (PCs), plays an important role in cadmium detoxification. The PCS and PCs are however not restricted to plants, but are also present in some lower metazoans. The model nematode Caenorhabditis elegans, for example, contains a fully functional phytochelatin synthase and phytochelatin pathway. By means of a transgenic nematode strain expressing a pcs-1 promoter-tagged GFP ( pcs-1::GFP) and a pcs-1 specific qPCR assay, further evidence is presentedmore » that the expression of the C. elegans phytochelatin synthase gene (pcs-1) is transcriptionally non-responsive to a chronic (48 h) insult of high levels of zinc (500 μM) or acute (3 h) exposures to high levels of cadmium (300 μM). However, the accumulation of cadmium, but not zinc, is dependent on the pcs-1 status of the nematode. Synchrotron based X-ray fluorescence imaging uncovered that the cadmium body burden increased significantly in the pcs-1(tm1748) knockout allele. Taken together, this suggests that whilst the transcription of pcs-1 may not be mediated by an exposure zinc or cadmium, it is nevertheless an integral part of the cadmium detoxification pathway in C. elegans.« less
Liu, Rebecca; Manes, Thomas D.; Qin, Lingfeng; Tietjen, Gregory T.; Broecker, Verena; Fang, Caodi; Xie, Catherine; Chen, Ping-Min; Kirkiles-Smith, Nancy C.; Jane-Wit, Dan; Pober, Jordan S.
2018-01-01
Early acute rejection of human allografts is mediated by circulating alloreactive host effector memory T cells (TEM). TEM infiltration typically occurs across graft postcapillary venules and involves sequential interactions with graft-derived endothelial cells (ECs) and pericytes (PCs). While the role of ECs in allograft rejection has been extensively studied, contributions of PCs to this process are largely unknown. This study aimed to characterize the effects and mechanisms of interactions between human PCs and allogeneic TEM. We report that unstimulated PCs, like ECs, can directly present alloantigen to TEM, but while IFN-γ–activated ECs (γ-ECs) show increased ability to stimulate alloreactive T cells, IFN-γ–activated PCs (γ-PCs) instead suppress TEM proliferation but not cytokine production or signaling. RNA sequencing analysis of PCs, γ-PCs, ECs, and γ-ECs reveal induction of indoleamine 2,3-dioxygenase 1 (IDO1) in γ-PCs to significantly higher levels than in γ-ECs that correlates with tryptophan depletion in vitro. Consistently, shRNA knockdown of IDO1 markedly reduces γ-PC–mediated immunoregulatory effects. Furthermore, human PCs express IDO1 in a skin allograft rejection humanized mouse model and in human renal allografts with acute T cell–mediated rejection. We conclude that immunosuppressive properties of human PCs are not intrinsic but instead result from IFN-γ–induced IDO1-mediated tryptophan depletion. PMID:29515027
DOE Office of Scientific and Technical Information (OSTI.GOV)
Essig, Yona J.; Webb, Samuel M.; Stürzenbaum, Stephen R.
Here, environmental metal pollution is a growing health risk to flora and fauna. It is therefore important to fully elucidate metal detoxification pathways. Phytochelatin synthase (PCS), an enzyme involved in the biosynthesis of phytochelatins (PCs), plays an important role in cadmium detoxification. The PCS and PCs are however not restricted to plants, but are also present in some lower metazoans. The model nematode Caenorhabditis elegans, for example, contains a fully functional phytochelatin synthase and phytochelatin pathway. By means of a transgenic nematode strain expressing a pcs-1 promoter-tagged GFP ( pcs-1::GFP) and a pcs-1 specific qPCR assay, further evidence is presentedmore » that the expression of the C. elegans phytochelatin synthase gene (pcs-1) is transcriptionally non-responsive to a chronic (48 h) insult of high levels of zinc (500 μM) or acute (3 h) exposures to high levels of cadmium (300 μM). However, the accumulation of cadmium, but not zinc, is dependent on the pcs-1 status of the nematode. Synchrotron based X-ray fluorescence imaging uncovered that the cadmium body burden increased significantly in the pcs-1(tm1748) knockout allele. Taken together, this suggests that whilst the transcription of pcs-1 may not be mediated by an exposure zinc or cadmium, it is nevertheless an integral part of the cadmium detoxification pathway in C. elegans.« less
Aligholi, Hadi; Rezayat, Seyed Mahdi; Azari, Hassan; Ejtemaei Mehr, Shahram; Akbari, Mohammad; Modarres Mousavi, Seyed Mostafa; Attari, Fatemeh; Alipour, Fatemeh; Hassanzadeh, Gholamreza; Gorji, Ali
2016-07-01
Cultivation of neural stem/progenitor cells (NS/PCs) in PuraMatrix (PM) hydrogel is an option for stem cell transplantation. The efficacy of a novel method for placing adult rat NS/PCs in PM (injection method) was compared to encapsulation and surface plating approaches. In addition, the efficacy of injection method for transplantation of autologous NS/PCs was studied in a rat model of brain injury. NS/PCs were obtained from the subventricular zone (SVZ) and cultivated without (control) or with scaffold (three-dimensional cultures; 3D). The effect of different approaches on survival, proliferation, and differentiation of NS/PCs were investigated. In in vivo study, brain injury was induced 45 days after NS/PCs were harvested from the SVZ and phosphate buffered saline, PM, NS/PCs, or PM+NS/PCs were injected into the brain lesion. There was an increase in cell viability and proliferation after injection and surface plating of NS/PCs compared to encapsulation and neural differentiation markers were expressed seven days after culturing the cells. Using injection method, transplantation of NS/PCs cultured in PM resulted in significant reduction of lesion volume, improvement of neurological deficits, and enhancement of surviving cells. In addition, the transplanted cells could differentiate in to neurons, astrocytes, or oligodendrocytes. Our results indicate that the injection and surface plating methods enhanced cell survival and proliferation of NS/PCs and suggest the injection method as a promising approach for transplantation of NS/PCs in brain injury. Copyright © 2016 Elsevier B.V. All rights reserved.
Functional characterization of an unusual phytochelatin synthase, LjPCS3, of Lotus japonicus.
Ramos, Javier; Naya, Loreto; Gay, Marina; Abián, Joaquín; Becana, Manuel
2008-09-01
In plants and many other organisms, phytochelatin synthase (PCS) catalyzes the synthesis of phytochelatins from glutathione in the presence of certain metals and metalloids. We have used budding yeast (Saccharomyces cerevisiae) as a heterologous system to characterize two PCS proteins, LjPCS1 and LjPCS3, of the model legume Lotus japonicus. Initial experiments revealed that the metal tolerance of yeast cells in vivo depends on the concentrations of divalent cations in the growth medium. Detailed in vivo (intact cells) and in vitro (broken cells) assays of PCS activity were performed with yeast expressing the plant enzymes, and values of phytochelatin production for each metal tested were normalized with respect to those of cadmium to correct for the lower expression level of LjPCS3. Our results showed that lead was the best activator of LjPCS1 in the in vitro assay, whereas, for both assays, arsenic, iron, and aluminum were better activators of LjPCS3 and mercury was similarly active with the two enzymes. Most interestingly, zinc was a powerful activator, especially of LjPCS3, when assayed in vivo, whereas copper and silver were the strongest activators in the in vitro assay. We conclude that the in vivo and in vitro assays are useful and complementary to assess the response of LjPCS1 and LjPCS3 to a wide range of metals and that the differences in the C-terminal domains of the two proteins are responsible for their distinct expression levels or stabilities in heterologous systems and patterns of metal activation.
Comet nucleus and asteroid sample return missions
NASA Technical Reports Server (NTRS)
Melton, Robert G.; Thompson, Roger C.; Starchville, Thomas F., Jr.; Adams, C.; Aldo, A.; Dobson, K.; Flotta, C.; Gagliardino, J.; Lear, M.; Mcmillan, C.
1992-01-01
During the 1991-92 academic year, the Pennsylvania State University has developed three sample return missions: one to the nucleus of comet Wild 2, one to the asteroid Eros, and one to three asteroids located in the Main Belt. The primary objective of the comet nucleus sample return mission is to rendezvous with a short period comet and acquire a 10 kg sample for return to Earth. Upon rendezvous with the comet, a tethered coring and sampler drill will contact the surface and extract a two-meter core sample from the target site. Before the spacecraft returns to Earth, a monitoring penetrator containing scientific instruments will be deployed for gathering long-term data about the comet. A single asteroid sample return mission to the asteroid 433 Eros (chosen for proximity and launch opportunities) will extract a sample from the asteroid surface for return to Earth. To limit overall mission cost, most of the mission design uses current technologies, except the sampler drill design. The multiple asteroid sample return mission could best be characterized through its use of future technology including an optical communications system, a nuclear power reactor, and a low-thrust propulsion system. A low-thrust trajectory optimization code (QuickTop 2) obtained from the NASA LeRC helped in planning the size of major subsystem components, as well as the trajectory between targets.
Auto-Gopher: A Wireline Deep Sampler Driven by Piezoelectric Percussive Actuator and EM Rotary Motor
NASA Technical Reports Server (NTRS)
Badescu, Mircea; Ressa, Aaron; Jae Lee, Hyeong; Bar-Cohen, Yoseph; Sherrit, Stewart; Zacny, Kris; Paulsen, Gale L.; Beegle, Luther; Bao, Xiaoqi
2013-01-01
The ability to penetrate subsurfaces and perform sample acquisition at depth of meters may be critical for future NASA in-situ exploration missions to bodies in the solar system, including Mars and Europa. A corer/sampler was developed with the goal of enabling acquisition of samples from depths of several meters where if used on Mars would be beyond the oxidized and sterilized zone. For this purpose, we developed a rotary-hammering coring drill, called Auto-Gopher, which employs a piezoelectric actuated percussive mechanism for breaking formations and an electric motor that rotates the bit to remove the powdered cuttings. This sampler is a wireline mechanism that can be fed into and retrieved from the drilled hole using a winch and a cable. It includes an inchworm anchoring mechanism allowing the drill advancement and weight on bit control without twisting the reeling and power cables. The penetration rate is being optimized by simultaneously activating the percussive and rotary motions of the Auto-Gopher. The percussive mechanism is based on the Ultrasonic/Sonic Drill/Corer (USDC) mechanism that is driven by piezoelectric stack and that was demonstrated to require low axial preload. The design and fabrication of this device were presented in previous publications. This paper presents the results of laboratory and field tests and lessons learned from this development.
Yang, Peng; Yang, Yingshu; Wang, Yinghui; Gao, Jiechao; Sui, Ning; Chi, Xiaochun; Zou, Lu; Zhang, Han-Zhuang
2016-02-01
The photoluminescence (PL) characteristics of CdSe quantum dots (QDs) infiltrated into inverse opal SiO2 photonic crystals (PCs) are systemically studied. The special porous structure of inverse opal PCs enhanced the thermal exchange rate between the CdSe QDs and their surrounding environment. Finally, inverse opal SiO2 PCs suppressed the nonlinear PL enhancement of CdSe QDs in PCs excited by a continuum laser and effectively modulated the PL characteristics of CdSe QDs in PCs at high temperatures in comparison with that of CdSe QDs out of PCs. The final results are of benefit in further understanding the role of inverse opal PCs on the PL characteristics of QDs. Copyright © 2015 John Wiley & Sons, Ltd.
Freeze core sampling to validate time-lapse resistivity monitoring of the hyporheic zone.
Toran, Laura; Hughes, Brian; Nyquist, Jonathan; Ryan, Robert
2013-01-01
A freeze core sampler was used to characterize hyporheic zone storage during a stream tracer test. The pore water from the frozen core showed tracer lingered in the hyporheic zone after the tracer had returned to background concentration in collocated well samples. These results confirmed evidence of lingering subsurface tracer seen in time-lapse electrical resistivity tomographs. The pore water exhibited brine exclusion (ion concentrations in ice lower than source water) in a sediment matrix, despite the fast freezing time. Although freeze core sampling provided qualitative evidence of lingering tracer, it proved difficult to quantify tracer concentration because the amount of brine exclusion during freezing could not be accurately determined. Nonetheless, the additional evidence for lingering tracer supports using time-lapse resistivity to detect regions of low fluid mobility within the hyporheic zone that can act as chemically reactive zones of importance in stream health. © 2012, The Author(s). GroundWater © 2012, National Ground Water Association.
Kühnlenz, Tanja; Schmidt, Holger; Uraguchi, Shimpei; Clemens, Stephan
2014-08-01
Phytochelatins play a key role in the detoxification of metals in plants and many other eukaryotes. Their formation is catalysed by phytochelatin synthases (PCS) in the presence of metal excess. It appears to be common among higher plants to possess two PCS genes, even though in Arabidopsis thaliana only AtPCS1 has been demonstrated to confer metal tolerance. Employing a highly sensitive quantification method based on ultraperformance electrospray ionization quadrupole time-of-flight mass spectrometry, we detected AtPCS2-dependent phytochelatin formation. Overexpression of AtPCS2 resulted in constitutive phytochelatin accumulation, i.e. in the absence of metal excess, both in planta and in a heterologous system. This indicates distinct enzymatic differences between AtPCS1 and AtPCS2. Furthermore, AtPCS2 was able to partially rescue the Cd hypersensitivity of the AtPCS1-deficient cad1-3 mutant in a liquid seedling assay, and, more importantly, when plants were grown on soil spiked with Cd to a level that is close to what can be found in agricultural soils. No rescue was found in vertical-plate assays, the most commonly used method to assess metal tolerance. Constitutive AtPCS2-dependent phytochelatin synthesis suggests a physiological role of AtPCS2 other than metal detoxification. The differences observed between wild-type plants and cad1-3 on Cd soil demonstrated: (i) the essentiality of phytochelatin synthesis for tolerating levels of Cd contamination that can naturally be encountered by plants outside of metal-rich habitats, and (ii) a contribution to Cd accumulation under these conditions. © The Author 2014. Published by Oxford University Press on behalf of the Society for Experimental Biology.
Provision of pharmaceutical care services in North Carolina: a 1999 survey.
McDermott, June H; Christensen, Dale B
2002-01-01
To describe the extent of and factors associated with the provision of pharmaceutical care services (PCS) and value-added pharmaceutical services (PS) by pharmacists in North Carolina, the physical changes made in pharmacies to accommodate these services, the nature and extent of prior consent or collaborative practice arrangements between North Carolina pharmacists and prescribers, and the frequency of reimbursement for PCS. Descriptive study based on a mail survey. Pharmacist-managers at each of the 2,048 licensed pharmacy sites in North Carolina; a list of licensed pharmacies provided by the North Carolina Board of Pharmacy was used as the sampling frame. Pharmacists' reports of PCS and pharmacy demographics. Response rate was 40%. More than 30% of respondents provided PCS at their site, although only 20% met our more stringent definition of PCS (i.e., ensuring appropriate pharmacotherapy, ensuring patient understanding and adherence, and monitoring and reporting patient outcomes). Services were more frequently offered by university-affiliated (35%) or independent (32%) pharmacies. The median number of patients receiving PCS across all sites was 10 per week. Diabetes was the most common health problem for which PCS were offered. Three variables-weekly prescription volume (positive correlation); number of staff pharmacists with advanced training, specifically fellowship training; and medical clinic/health maintenance organization setting-were significant predictors of the numbers of patients provided PCS. Independent community pharmacies were most likely to have private counseling areas and to bill for and receive payment for PCS. In North Carolina, a substantial number of pharmacists provided PCS in 1999 or planned to do so in the near future. However, the number of patients receiving PCS was relatively low. Practice setting, pharmacist education level, and prescription volume were weakly predictive of the number of patients receiving PCS. Pharmacists commonly used prior consent arrangements with physicians in their practices, but primarily to facilitate generic substitution. Relatively few pharmacists billed for PS or PCS.
NASA Astrophysics Data System (ADS)
Markovic, Milos Z.; Prokop, Sebastian; Staebler, Ralf M.; Liggio, John; Harner, Tom
2015-07-01
The particle infiltration efficiencies (PIE) of three passive and one active air samplers were evaluated under field conditions. A wide-range particle spectrometer operating in the 250-4140 nm range was used to acquire highly temporally resolved particle-number and size distributions for the different samplers compared to ambient air. Overall, three of the four evaluated samplers were able to acquire a representative sample of ambient particles with PIEs of 91.5 ± 13.7% for the GAPS Network sampler, 103 ± 15.5% for the Lancaster University sampler, and 89.6 ± 13.4% for a conventional PS-1 high-volume active air sampler (Hi-Vol). Significantly (p = 0.05) lower PIE of 54 ± 8.0% was acquired for the passive sampler used under the MONET program. These findings inform the comparability and use of passive and active samplers for measuring particle-associated priority chemicals in air.
Thompson, Jon S.; Porter, Kendrick A.; Hayashida, Nobuo; McNamara, Donald J.; Parker, Thomas S.; Russell, William J. I.; Francavilla, Antonio; Starzl, Thomas E.
2010-01-01
External biliary fistula (BF) or ileal bypass (IB) was performed in dogs at the time of or 2 weeks after portacaval shunt (PCS). The pathologic changes in the dog livers 2 to 4 weeks later were compared to those caused by PCS alone. Histopathologic differences between PCS alone vs. PCS plus BF or IB could not be found. Thus, the experiments did not confirm recent observations by others in rats that BF prevents or reverses the hepatic injury of PCS. As estimated by plasma mevalonic acid determinations, the increase in hepatic cholesterol synthesis that is characteristic after BF or IB was suppressed in animals with PCS. BF and IB reduced but did not eliminate the postprandial elevation in serum bile acid that occurs after PCS. The findings have possible relevance in planning the treatment of patients with familial hypercholesterolemia with the combined use of PCS and IB. PMID:6862371
Kobayashi, J; Yanagisawa, R; Ono, T; Tatsuzawa, Y; Tokutake, Y; Kubota, N; Hidaka, E; Sakashita, K; Kojima, S; Shimodaira, S; Nakamura, T
2018-02-01
Adverse reactions to platelet transfusions are a problem. Children with primary haematological and malignant diseases may experience allergic transfusion reactions (ATRs) to platelet concentrates (PCs), which can be prevented by giving washed PCs. A new platelet additive solution, using bicarbonated Ringer's solution and acid-citrate-dextrose formula A (BRS-A), may be better for platelet washing and storage, but clinical data are scarce. A retrospective cohort study for consecutive cases was performed between 2013 and 2017. For 24 months, we transfused washed PCs containing BRS-A to children with primary haematological and malignant diseases and previous adverse reactions. Patients transfused with conventional PCs (containing residual plasma) were assigned as controls, and results were compared in terms of frequency of ATRs, corrected count increment (CCI) and occurrence of bleeding. We also studied children transfused with PCs washed by a different system as historical controls. Thirty-two patients received 377 conventional PC transfusions. ATRs occurred in 12 (37·5%) patients from transfused with 18 (4·8%) bags. Thirteen patients, who experienced reactions to regular PCs in plasma, then received 119 transfusion bags of washed PCs containing BRS-A, and none had ATRs to washed PCs containing BRS-A. Before study period, six patients transfused 137 classical washed PCs with different platelet additive solution, under same indication, ATRs occurred in one (16·7%) patient from transfused with one (0·7%) bags. CCIs (24 h) in were lower with classical washed PCs (1·26 ± 0·54) compared to regular PCs in plasma (2·07 ± 0·76) (P < 0·001), but there was no difference between washed PCs containing BRS-A (2·14 ± 0·77) and regular PCs (2·21 ± 0·79) (P = 0·769), and we saw no post-transfusion bleeding. Washed PCs containing BRS-A appear to prevent ATRs without loss of transfusion efficacy in children with primary haematological and malignant diseases. Their efficacy should be further evaluated through larger prospective clinical trials. © 2017 International Society of Blood Transfusion.
Zawadzki, Matthew J; Sliwinski, Martin J; Smyth, Joshua M
2018-03-29
Both exposure to stress and perseverative cognitions (PCs)-repetitive cognitive representations of real or imagined stressors-are linked with poor psychological health. Yet, stress exposure and PCs are correlated, thus potentially obscuring any unique effects. The purpose of this paper is to concurrently test associations between stress exposure and PCs and psychological health to examine the independent relationship of each with psychological health. Moreover, we examined whether these relationships are similar across sex, age, and race. An adult community sample (n = 302) completed a measure of stress exposure, three PCs scales, and questionnaires assessing self-reported psychological health, including emotional well-being, vitality, social functioning, role limitations due to personal problems, subjective well-being, depressive symptoms, and poor sleep quality. Structural equation modeling was used to test a model in which both stress exposure and PCs predict psychological health. PCs consistently predicted all the psychological health outcomes, but stress was largely unrelated to the outcomes despite bivariate correlations suggesting a relationship. A follow-up model identified indirect effects of stress exposure on psychological health via PCs. Results were fairly consistent regardless of one's sex, age, or race. PCs robustly predicted all of the psychological health outcomes, intimating PCs as a common pathway to poor psychological health. Results have implications for stress interventions, including the need to address PCs after experiencing stress.
Malta, Tathiane Maistro; de Deus Wagatsuma, Virgínia Mara; Palma, Patrícia Viana Bonini; Araújo, Amélia Goes; Ribeiro Malmegrim, Kelen Cristina; Morato de Oliveira, Fábio; Panepucci, Rodrigo Alexandre; Silva, Wilson Araújo; Kashima Haddad, Simone; Covas, Dimas Tadeu
2015-01-01
Mesenchymal stromal cells (MSCs) are cultured cells that can give rise to mature mesenchymal cells under appropriate conditions and secrete a number of biologically relevant molecules that may play an important role in regenerative medicine. Evidence indicates that pericytes (PCs) correspond to mesenchymal stem cells in vivo and can give rise to MSCs when cultured, but a comparison between the gene expression profiles of cultured PCs (cPCs) and MSCs is lacking. We have devised a novel methodology to isolate PCs from human adipose tissue and compared cPCs to MSCs obtained through traditional methods. Freshly isolated PCs expressed CD34, CD140b, and CD271 on their surface, but not CD146. Both MSCs and cPCs were able to differentiate along mesenchymal pathways in vitro, displayed an essentially identical surface immunophenotype, and exhibited the ability to suppress CD3+ lymphocyte proliferation in vitro. Microarray expression data of cPCs and MSCs formed a single cluster among other cell types. Further analyses showed that the gene expression profiles of cPCs and MSCs are extremely similar, although MSCs differentially expressed endothelial cell (EC)-specific transcripts. These results confirm, using the power of transcriptomic analysis, that PCs give rise to MSCs and suggest that low levels of ECs may persist in MSC cultures established using traditional protocols. PMID:26192741
NASA Astrophysics Data System (ADS)
Niwase, Hiroaki; Takada, Naoki; Araki, Hiromitsu; Maeda, Yuki; Fujiwara, Masato; Nakayama, Hirotaka; Kakue, Takashi; Shimobaba, Tomoyoshi; Ito, Tomoyoshi
2016-09-01
Parallel calculations of large-pixel-count computer-generated holograms (CGHs) are suitable for multiple-graphics processing unit (multi-GPU) cluster systems. However, it is not easy for a multi-GPU cluster system to accomplish fast CGH calculations when CGH transfers between PCs are required. In these cases, the CGH transfer between the PCs becomes a bottleneck. Usually, this problem occurs only in multi-GPU cluster systems with a single spatial light modulator. To overcome this problem, we propose a simple method using the InfiniBand network. The computational speed of the proposed method using 13 GPUs (NVIDIA GeForce GTX TITAN X) was more than 3000 times faster than that of a CPU (Intel Core i7 4770) when the number of three-dimensional (3-D) object points exceeded 20,480. In practice, we achieved ˜40 tera floating point operations per second (TFLOPS) when the number of 3-D object points exceeded 40,960. Our proposed method was able to reconstruct a real-time movie of a 3-D object comprising 95,949 points.
Protein-bounded uremic toxin p-cresylsulfate induces vascular permeability alternations.
Tang, Wei-Hua; Wang, Chao-Ping; Yu, Teng-Hung; Tai, Pei-Yang; Liang, Shih-Shin; Hung, Wei-Chin; Wu, Cheng-Ching; Huang, Sung-Hao; Lee, Yau-Jiunn; Chen, Shih-Chieh
2018-06-01
The goal of the present studies is to investigate that the impact of p-cresylsulfate (PCS) on the endothelial barrier integrity via in situ exposure and systemic exposure. Vascular permeability changes induced by local injection of PCS were evaluated by the techniques of both Evans blue (EB) and India ink tracer. Rats were intravenously injected with EB or India ink followed by intradermal injections of various doses of PCS (0, 0.4, 2, 10 and 50 µmol/site) on rat back skins. At different time points, skin EB was extracted and quantified. The administration of India ink was used to demonstrate leaky microvessels. Skin PCS levels were also determined by liquid chromatography-mass spectrometry. We also investigated whether the increased endothelial leakage occurred in the aortic endothelium in rats treated with 5/6 nephrectomy and intraperitoneal injection of PCS 50 mg/kg/day for 4 weeks. The aortic endothelial integrity was evaluated by increased immunoglobulin G (IgG) leakage. High doses of PCS, but not lower doses, significantly induced vascular leakage as compared to saline injection and EB leakage exhibited in time-dependent manner. A time-correlated increase in leaky microvessels was detected in the tissues examined. The injected PCS declined with time and displayed an inverse relationship with vascular leakage. Chronic kidney disease (CKD) rats administered with PCS, compared to control rats, had significantly higher serum levels of PCS and apparent IgG deposition in the aortic intima. Increased endothelial leakage induced by PCS in skin microvessels and the aorta of CKD rats suggests that the PCS-induced endothelial barrier dysfunction.
Vroblesky, Don A.; Joshi, Manish; Morrell, Jeff; Peterson, J.E.
2003-01-01
During March-April 2002, the U.S. Geological Survey, Earth Tech, and EA Engineering, Science, and Technology, Inc., in cooperation with the Air Force Center for Environmental Excellence, tested diffusion samplers at Andersen Air Force Base, Guam. Samplers were deployed in three wells at the Main Base and two wells at Marianas Bonins (MARBO) Annex as potential ground-water monitoring alternatives. Prior to sampler deployment, the wells were tested using a borehole flowmeter to characterize vertical flow within each well. Three types of diffusion samplers were tested: passive diffusion bag (PDB) samplers, dialysis samplers, and nylon-screen samplers. The primary volatile organic compounds (VOCs) tested in ground water at Andersen Air Force Base were trichloroethene and tetrachloroethene. In most comparisons, trichloroethene and tetrachloroethene concentrations in PDB samples closely matched concentrations in pumped samples. Exceptions were in wells where the pumping or ambient flow produced vertical translocation of water in a chemically stratified aquifer. In these wells, PDB samplers probably would be a viable alternative sampling method if they were placed at appropriate depths. In the remaining three test wells, the trichloroethene or tetrachloroethene concentrations obtained with the diffusion samplers closely matched the result from pumped sampling. Chloride concentrations in nylon-screen samplers were compared with chloride concentrations in dialysis and pumped samples to test inorganic-solute diffusion into the samplers across a range of concentrations. The test showed that the results from nylon-screen samplers might have underestimated chloride concentrations at depths with elevated chloride concentrations. The reason for the discrepancy in this investigation is unknown, but may be related to nylon-screen-mesh size, which was smaller than that used in previous investigations.
The influence of geometry and draught shields on the performance of passive samplers.
Hofschreuder, P; van der Meulen, W; Heeres, P; Slanina, S
1999-04-01
Passive samplers provide an excellent opportunity to perform indicative measurements or establish a dense network of measuring sites. A drawback compared with conventional active measuring methods is the larger spread of results. This variation can, to a large extent, be attributed to the influence of temperature, sampler geometry and wind on sampling results. A proper design of sampler geometry and optimum choice of draught shield can reduce the influence of wind velocity on a badge type sampler to less than 10%. Wire mesh screens prove to be inadequate in damping turbulence. Filters give good results. Attention should be paid to the size and isolation value of the walls of the sampler to prevent thermal updrafts occurring within the sampler. Tube type samplers are less influenced by wind, provided that turbulence is prevented from influencing diffusion within the sampler.
Tests of Rock Cores Michigamme Study Area, Michigan
1970-06-01
cca;c-rraincd tona- l ".1 ., reck with dis - ’ pte, --’gmatite bands. MG-CR-26 SAMcO-9, DC-2 2 17 Black and white, medium- grtlned gn.insic ,onalite. I...4 . :t:::*.::: l N . . ......... 20,000 W:., ..... ... ... ... ...... ....... ... . .1. 1:: t: :1:1:1 N.: .111:::: Fiji. milIA : -mit: 15.00C :N...PCS13.60/MF$3.00 SutrdPormigSre.Vl l siae V Bilogcal ervcesProgam.Fisal Yar 975Software Project Resource Requirement* PADA251 738/PAT 52 p PC$4.50
NASA Astrophysics Data System (ADS)
O'Shea, Peter; Laberge, Michel; Mossman, Alex; Reynolds, Meritt
2017-10-01
Magnetic reconstructions on lab based plasma injectors at General Fusion relies heavily on edge magnetic (``Bdot'') probes. On plasma experiments built for field compression (PCS) tests, the number and locations of Bdot probes is limited by mechanical constraints. Additional information about the q profiles near the core in our Spector plasmas is obtained using passive MHD spectroscopy. The coaxial helicity injection (CHI) formation process naturally generates hollow current profiles and reversed shear early in each discharge. Central Ohmic heating naturally peaks the current profiles as our plasmas evolve in time, simultaneously reducing the core safety factor, q(0), and reverse shear. As the central, non-monotonic q-profile crosses rational flux surfaces, we observe transient magnetic reconnection events (MRE's) due to the double tearing mode. Modal analysis allows us to infer the q surfaces involved in each burst. The parametric dependence of the timing of MRE's allows us to estimate the continuous time evolution of the core q profile. Combining core MHD spectroscopy with edge magnetic probe measurements greatly enhances our certainty of the overall q profile.
Pricing the property claim service (PCS) catastrophe insurance options using gamma distribution
NASA Astrophysics Data System (ADS)
Noviyanti, Lienda; Soleh, Achmad Zanbar; Setyanto, Gatot R.
2017-03-01
The catastrophic events like earthquakes, hurricanes or flooding are characteristics for some areas, a properly calculated annual premium would be closely as high as the loss insured. From an actuarial perspective, such events constitute the risk that are not insurable. On the other hand people living in such areas need protection. In order to securitize the catastrophe risk, futures or options based on a loss index could be considered. Chicago Board of Trade launched a new class of catastrophe insurance options based on new indices provided by Property Claim Services (PCS). The PCS-option is based on the Property Claim Service Index (PCS-Index). The index are used to determine and payout in writing index-based insurance derivatives. The objective of this paper is to price PCS Catastrophe Insurance Option based on PCS Catastrophe index. Gamma Distribution is used to estimate PCS Catastrophe index distribution.
The plantar calcaneal spur: a review of anatomy, histology, etiology and key associations.
Kirkpatrick, Joshua; Yassaie, Omid; Mirjalili, Seyed Ali
2017-06-01
The plantar calcaneal spur (PCS) is a bony outgrowth from the calcaneal tuberosity and has been studied using various methods including cadavers, radiography, histology and surgery. However, there are currently a number of discrepancies in the literature regarding the anatomical relations, histological descriptions and clinical associations of PCS. Historically, authors have described the intrinsic muscles of the foot and/or the plantar fascia as attaching to the PCS. In this article we review the relationship between the PCS and surrounding soft tissues as well as examining the histology of the PCS. We identify a number of key associations with PCS, including age, weight, gender, arthritides, plantar fasciitis and foot position; these factors may function as risk factors in PCS formation. The etiology of these spurs is a contentious issue and it has been explained through a number of theories including the degenerative, inflammatory, traction, repetitive trauma, bone-formers and vertical compression theories. We review these and finish by looking clinically at the evidence that PCS causes heel pain. © 2017 Anatomical Society.
Kühnlenz, Tanja; Westphal, Lore; Schmidt, Holger; Scheel, Dierk; Clemens, Stephan
2015-11-01
Phytochelatin synthases (PCS) play key roles in plant metal tolerance. They synthesize small metal-binding peptides, phytochelatins, under conditions of metal excess. Respective mutants are strongly cadmium and arsenic hypersensitive. However, their ubiquitous presence and constitutive expression had long suggested a more general function of PCS besides metal detoxification. Indeed, phytochelatin synthase1 from Arabidopsis thaliana (AtPCS1) was later implicated in non-host resistance. The two different physiological functions may be attributable to the two distinct catalytic activities demonstrated for AtPCS1, that is the dipeptidyl transfer onto an acceptor molecule in phytochelatin synthesis, and the proteolytic deglycylation of glutathione conjugates. In order to test this hypothesis and to possibly separate the two biological roles, we expressed a phylogenetically distant PCS from Caenorhabditis elegans in an AtPCS1 mutant. We confirmed the involvement of AtPCS1 in non-host resistance by showing that plants lacking the functional gene develop a strong cell death phenotype when inoculated with the potato pathogen Phytophthora infestans. Furthermore, we found that the C. elegans gene rescues phytochelatin synthesis and cadmium tolerance, but not the defect in non-host resistance. This strongly suggests that the second enzymatic function of AtPCS1, which remains to be defined in detail, is underlying the plant immunity function. © 2015 John Wiley & Sons Ltd.
Liu, Rebecca; Lauridsen, Holly M.; Amezquita, Robert A.; Pierce, Richard W.; Jane-wit, Dan; Fang, Caodi; Pellowe, Amanda S.; Kirkiles-Smith, Nancy C.; Gonzalez, Anjelica L.; Pober, Jordan S.
2016-01-01
A classical hallmark of acute inflammation is neutrophil infiltration of tissues, a multi-step process that involves sequential cell-cell interactions of circulating leukocytes with interleukin (IL)-1- or tumor necrosis factor-α (TNF)-activated microvascular endothelial cells (ECs) and pericytes (PCs) that form the wall of the postcapillary venules. The initial infiltrating cells accumulate perivascularly in close proximity to PCs. IL-17, a pro-inflammatory cytokine that acts on target cells via a heterodimeric receptor formed by IL-17RA and IL-17RC subunits, also promotes neutrophilic inflammation but its effects on vascular cells are less clear. We report that both cultured human ECs and PCs strongly express IL-17RC and, while neither cell type expresses much IL-17RA, PCs express significantly more than ECs. IL-17, alone or synergistically with TNF, significantly alters inflammatory gene expression in cultured human PCs but not ECs. RNA-seq analysis identifies many IL-17-induced transcripts in PCs encoding proteins known to stimulate neutrophil-mediated immunity. Conditioned media (CM) from IL-17-activated PCs, but not ECs, induce pertussis toxin-sensitive neutrophil polarization, likely mediated by PC-secreted chemokines, and also stimulate neutrophil production of pro-inflammatory molecules, including TNF, IL-1α, IL-1β, and IL-8. Furthermore, IL-17-activated PCs but not ECs can prolong neutrophil survival by producing G-CSF and GM-CSF, delaying the mitochondria outer membrane permeabilization and caspase 9 activation. Importantly, neutrophils exhibit enhanced phagocytic capacity after activation by CM from IL-17-treated PCs. We conclude that PCs, not ECs, are the major target of IL-17 within the microvessel wall and that IL-17-activated PCs can modulate neutrophil functions within the perivascular tissue space. PMID:27534549
Framework for Integrating Science Data Processing Algorithms Into Process Control Systems
NASA Technical Reports Server (NTRS)
Mattmann, Chris A.; Crichton, Daniel J.; Chang, Albert Y.; Foster, Brian M.; Freeborn, Dana J.; Woollard, David M.; Ramirez, Paul M.
2011-01-01
A software framework called PCS Task Wrapper is responsible for standardizing the setup, process initiation, execution, and file management tasks surrounding the execution of science data algorithms, which are referred to by NASA as Product Generation Executives (PGEs). PGEs codify a scientific algorithm, some step in the overall scientific process involved in a mission science workflow. The PCS Task Wrapper provides a stable operating environment to the underlying PGE during its execution lifecycle. If the PGE requires a file, or metadata regarding the file, the PCS Task Wrapper is responsible for delivering that information to the PGE in a manner that meets its requirements. If the PGE requires knowledge of upstream or downstream PGEs in a sequence of executions, that information is also made available. Finally, if information regarding disk space, or node information such as CPU availability, etc., is required, the PCS Task Wrapper provides this information to the underlying PGE. After this information is collected, the PGE is executed, and its output Product file and Metadata generation is managed via the PCS Task Wrapper framework. The innovation is responsible for marshalling output Products and Metadata back to a PCS File Management component for use in downstream data processing and pedigree. In support of this, the PCS Task Wrapper leverages the PCS Crawler Framework to ingest (during pipeline processing) the output Product files and Metadata produced by the PGE. The architectural components of the PCS Task Wrapper framework include PGE Task Instance, PGE Config File Builder, Config File Property Adder, Science PGE Config File Writer, and PCS Met file Writer. This innovative framework is really the unifying bridge between the execution of a step in the overall processing pipeline, and the available PCS component services as well as the information that they collectively manage.
Thibault, Pascal; Abbott, J Haxby; Jensen, Mark P
2018-01-01
Background Pain catastrophizing is an exaggerated negative cognitive response related to pain. It is commonly assessed using the Pain Catastrophizing Scale (PCS). Translation and validation of the scale in a new language would facilitate cross-cultural comparisons of the role that pain catastrophizing plays in patient function. Purpose The aim of this study was to translate and culturally adapt the PCS into Nepali (Nepali version of PCS [PCS-NP]) and evaluate its clinimetric properties. Methods We translated, cross-culturally adapted, and performed an exploratory factor analysis (EFA) of the PCS-NP in a sample of adults with chronic pain (N=143). We then confirmed the resulting factor model in a separate sample (N=272) and compared this model with 1-, 2-, and 3-factor models previously identified using confirmatory factor analyses (CFAs). We also computed internal consistencies, test–retest reliabilities, standard error of measurement (SEM), minimal detectable change (MDC), and limits of agreement with 95% confidence interval (LOA95%) of the PCS-NP scales. Concurrent validity with measures of depression, anxiety, and pain intensity was assessed by computing Pearson’s correlation coefficients. Results The PCS-NP was comprehensible and culturally acceptable. We extracted a two-factor solution using EFA and confirmed this model using CFAs in the second sample. Adequate fit was also found for a one-factor model and different two- and three-factor models based on prior studies. The PCS-NP scores evidenced excellent reliability and temporal stability, and demonstrated validity via moderate-to-strong associations with measures of depression, anxiety, and pain intensity. The SEM and MDC for the PCS-NP total score were 2.52 and 7.86, respectively (range of PCS scores 0–52). LOA95% was between −15.17 and +16.02 for the total PCS-NP scores. Conclusion The PCS-NP is a valid and reliable instrument to assess pain catastrophizing in Nepalese individuals with chronic pain. PMID:29430196
A modified siphon sampler for shallow water
Diehl, Timothy H.
2008-01-01
A modified siphon sampler (or 'single-stage sampler') was developed to sample shallow water at closely spaced vertical intervals. The modified design uses horizontal rather than vertical sample bottles. Previous siphon samplers are limited to water about 20 centimeters (cm) or more in depth; the modified design can sample water 10 cm deep. Several mounting options were used to deploy the modified siphon sampler in shallow bedrock streams of Middle Tennessee, while minimizing alteration of the stream bed. Sampling characteristics and limitations of the modified design are similar to those of the original design. Testing showed that the modified sampler collects unbiased samples of suspended silt and clay. Similarity of the intake to the original siphon sampler suggests that the modified sampler would probably take downward-biased samples of suspended sand. Like other siphon samplers, it does not sample isokinetically, and the efficiency of sand sampling can be expected to change with flow velocity. The sampler needs to be located in the main flow of the stream, and is subject to damage from rapid flow and floating debris. Water traps were added to the air vents to detect the flow of water through the sampler, which can cause a strong upward bias in sampled suspended-sediment concentration. Water did flow through the sampler, in some cases even when the top of the air vent remained above water. Air vents need to be extended well above maximum water level to prevent flow through the sampler.
Kang, J E; Yu, J M; Choi, J H; Chung, I-M; Pyun, W B; Kim, S A; Lee, E K; Han, N Y; Yoon, J-H; Oh, J M; Rhie, S J
2018-06-01
Drug therapies are critical for preventing secondary complications in acute coronary syndrome (ACS). The purpose of this study was to develop and apply a pharmaceutical care service (PCS) algorithm for ACS and confirm that it is applicable through a prospective clinical trial. The ACS-PCS algorithm was developed according to extant evidence-based treatment and pharmaceutical care guidelines. Quality assurance was conducted through two methods: literature comparison and expert panel evaluation. The literature comparison was used to compare the content of the algorithm with the referenced guidelines. Expert evaluations were conducted by nine experts for 75 questionnaire items. A trial was conducted to confirm its effectiveness. Seventy-nine patients were assigned to either the pharmacist-included multidisciplinary team care (MTC) group or the usual care (UC) group. The endpoints of the trial were the prescription rate of two important drugs, readmission, emergency room (ER) visit and mortality. The main frame of the algorithm was structured with three tasks: medication reconciliation, medication optimization and transition of care. The contents and context of the algorithm were compliant with class I recommendations and the main service items from the evidence-based guidelines. Opinions from the expert panel were mostly positive. There were significant differences in beta-blocker prescription rates in the overall period (P = .013) and ER visits (four cases, 9.76%, P = .016) in the MTC group compared to the UC group, respectively. We developed a PCS algorithm for ACS based on the contents of evidence-based drug therapy and the core concept of pharmacist services. © 2018 John Wiley & Sons Ltd.
Physics of Colloids in Space--Plus (PCS+) Experiment Completed Flight Acceptance Testing
NASA Technical Reports Server (NTRS)
Doherty, Michael P.
2004-01-01
The Physics of Colloids in Space--Plus (PCS+) experiment successfully completed system-level flight acceptance testing in the fall of 2003. This testing included electromagnetic interference (EMI) testing, vibration testing, and thermal testing. PCS+, an Expedite the Process of Experiments to Space Station (EXPRESS) Rack payload will deploy a second set of colloid samples within the PCS flight hardware system that flew on the International Space Station (ISS) from April 2001 to June 2002. PCS+ is slated to return to the ISS in late 2004 or early 2005.
Permeability of sediment cores from methane hydrate deposit in the Eastern Nankai Trough, Japan
NASA Astrophysics Data System (ADS)
Konno, Y.; Yoneda, J.; Egawa, K.; Ito, T.; Jin, Y.; Kida, M.; Suzuki, K.; Nakatsuka, Y.; Nagao, J.
2013-12-01
Effective and absolute permeability are key parameters for gas production from methane-hydrate-bearing sandy sediments. Effective and/or absolute permeability have been measured using methane-hydrate-bearing sandy cores and clayey and silty cores recovered from Daini Atsumi Knoll in the Eastern Nankai Trough during the 2012 JOGMEC/JAPEX Pressure coring operation. Liquid-nitrogen-immersed cores were prepared by rapid depressurization of pressure cores recovered by a pressure coring system referred to as the Hybrid PCS. Cores were shaped cylindrically on a lathe with spraying of liquid nitrogen to prevent hydrate dissociation. Permeability was measured by a flooding test or a pressure relaxation method under near in-situ pressure and temperature conditions. Measured effective permeability of hydrate-bearing sediments is less than tens of md, which are order of magnitude less than absolute permeability. Absolute permeability of clayey cores is approximately tens of μd, which would perform a sealing function as cap rocks. Permeability reduction due to a swelling effect was observed for a silty core during flooding test of pure water mimicking hydrate-dissociation-water. Swelling effect may cause production formation damage especially at a later stage of gas production from methane hydrate deposits. This study was financially supported by the Research Consortium for Methane Hydrate Resources in Japan (MH21 Research Consortium) that carries out Japan's Methane Hydrate R&D Program conducted by the Ministry of Economy, Trade and Industry (METI).
50 CFR 697.12 - At-sea sea sampler/observer coverage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 50 Wildlife and Fisheries 13 2013-10-01 2013-10-01 false At-sea sea sampler/observer coverage. 697... MANAGEMENT General Provisions § 697.12 At-sea sea sampler/observer coverage. (a) The Regional Administrator...-approved sea sampler/observer. If requested by the Regional Administrator to carry a sea sampler/observer...
50 CFR 697.12 - At-sea sea sampler/observer coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 13 2012-10-01 2012-10-01 false At-sea sea sampler/observer coverage. 697... MANAGEMENT General Provisions § 697.12 At-sea sea sampler/observer coverage. (a) The Regional Administrator...-approved sea sampler/observer. If requested by the Regional Administrator to carry a sea sampler/observer...
50 CFR 697.12 - At-sea sea sampler/observer coverage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 50 Wildlife and Fisheries 13 2014-10-01 2014-10-01 false At-sea sea sampler/observer coverage. 697... MANAGEMENT General Provisions § 697.12 At-sea sea sampler/observer coverage. (a) The Regional Administrator...-approved sea sampler/observer. If requested by the Regional Administrator to carry a sea sampler/observer...
7 CFR 61.30 - Examination of sampler.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Examination of sampler. 61.30 Section 61.30... Cottonseed Samplers § 61.30 Examination of sampler. Each applicant for a license as a sampler and each... examination or test to show his ability properly to perform the duties for which he is applying for a license...
Falls, W. Fred; Caldwell, Andral W.; Guimaraes, Wladmir G.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2012-01-01
Soil-gas and groundwater assessments were conducted at the Gibson Road landfill in 201 to provide screening-level environmental contamination data to supplement the data collected during previous environmental studies at the landfill. Passive samplers were used in both assessments to detect volatile and semivolatile organic compounds and polycyclic aromatic hydrocarbons in soil gas and groundwater. A total of 56 passive samplers were deployed in the soil in late July and early August for the soil-gas assessment. Total petroleum hydrocarbons (TPH) were detected at masses greater than the method detection level of 0.02 microgram in all samplers and masses greater than 2.0 micrograms in 13 samplers. Three samplers located between the landfill and a nearby wetland had TPH masses greater than 20 micrograms. Diesel was detected in 28 of the 56 soil-gas samplers. Undecane, tridecane, and pentadecane were detected, but undecane was the most common diesel compound with 23 detections. Only five detections exceeded a combined diesel mass of 0.10 microgram, including the highest mass of 0.27 microgram near the wetland. Toluene was detected in only five passive samplers, including masses of 0.65 microgram near the wetland and 0.85 microgram on the southwestern side of the landfill. The only other gasoline-related compound detected was octane in two samplers. Naphthalene was detected in two samplers in the gully near the landfill and two samplers along the southwestern side of the landfill, but had masses less than or equal to 0.02 microgram. Six samplers located southeast of the landfill had detections of chlorinated compounds, including one perchloroethene detections (0.04 microgram) and five chloroform detections (0.05 to0.08 microgram). Passive samplers were deployed and recovered on August 8, 2011, in nine monitoring wells along the southwestern, southeastern and northeastern sides of the landfill and down gradient from the eastern corner of the landfill. Six of the nine samplers had TPH concentrations greater than 100 micrograms per liter. TPH concentrations declined from 320 micrograms per liter in a sampler near the landfill to 18 micrograms in a sampler near the wetland. Five of the samplers had detections of one or more diesel compounds but detections of individual diesel compounds had concentrations below a method detection level of 0.01 microgram per liter. Benzene was detected in three samplers and exceeded the national primary drinking-water standard of 5 micrograms per liter set by the U.S. Environmental Protection Agency. The concentrations of benzene, and therefore BTEX, were 6.1 micrograms per liter in the sampler near the eastern corner of the landfill, 27 micrograms per liter in the sampler near the wetland, and 37 micrograms per liter in the sampler at the southern corner of the landfill. Nonfuel-related compounds were detected in the four wells that are aligned between the eastern corner of the landfill and the wetland. The sampler deployed nearest the eastern corner of the landfill had the greatest number of detected organic compounds and had the only detections of two trimethylbenzene compounds, naphthalene, 2-methyl naphthalene, and 1,4-dichlorobenzene. The two up gradient samplers had the greatest number of chlorinated compounds with five compounds each, compared to detections of four compounds and one compound in the two down gradient samplers. All four samplers had detections of 1,1-dichloroethane which ranged from 42 to 1,300 micrograms per liter. Other detections of chlorinated compounds included trichloroethene, perchloroethene, cis-1,2-dichloroethene, 1,1,1-trichloroethane and chloroform.
Pham, Anh Le-Tuan; Johnson, Carol; Manley, Devon; Hsu-Kim, Heileen
2015-11-03
Diffusive gradient in thin-film (DGT) passive samplers are frequently used to monitor the concentrations of metals such as mercury and zinc in sediments and other aquatic environments. The application of these samplers generally presumes that they quantify only the dissolved fraction and not particle-bound metal species that are too large to migrate into the sampler. However, metals associated with very small nanoparticles (smaller than the pore size of DGT samplers) can be abundant in certain environments, yet the implications of these nanoparticles for DGT measurements are unclear. The objective of this study was to determine how the performance of the DGT sampler is affected by the presence of nanoparticulate species of Hg and Zn. DGT samplers were exposed to solutions containing known amounts of dissolved Hg(II) and nanoparticulate HgS (or dissolved Zn(II) and nanoparticulate ZnS). The amounts of Hg and Zn accumulated onto the DGT samplers were quantified over hours to days, and the rates of diffusion of the dissolved metal (i.e., the effective diffusion coefficient D) into the sampler's diffusion layer were calculated and compared for solutions containing varying concentrations of nanoparticles. The results suggested that the nanoparticles deposited on the surface of the samplers might have acted as sorbents, slowing the migration of the dissolved species into the samplers. The consequence was that the DGT sampler data underestimated the dissolved metal concentration in the solution. In addition, X-ray absorption spectroscopy was employed to determine the speciation of the Hg accumulated on the sampler binding layer, and the results indicated that HgS nanoparticles did not appear to directly contribute to the DGT measurement. Overall, our findings suggest that the deployment of DGT samplers in settings where nanoparticles are relevant (e.g., sediments) may result in DGT data that incorrectly estimated the dissolved metal concentrations. Models for metal uptake into the sampler may need to be reconsidered.
Arvidsson, Tommy; Bergström, Lars; Kreuger, Jenny
2011-06-01
In this study, the collecting efficiency of different samplers of airborne drift was compared both in wind tunnel and in field experiments. The aim was to select an appropriate sampler for collecting airborne spray drift under field conditions. The wind tunnel study examined three static samplers and one dynamic sampler. The dynamic sampler had the highest overall collecting efficiency. Among the static samplers, the pipe cleaner collector had the highest efficiency. These two samplers were selected for evaluation in the subsequent field study. Results from 29 individual field experiments showed that the pipe cleaner collector on average had a 10% lower collecting efficiency than the dynamic sampler. However, the deposits on the pipe cleaners generally were highest at the 0.5 m level, and for the dynamic sampler at the 1 m level. It was concluded from the wind tunnel part of the study that the amount of drift collected on the static collectors had a more strongly positive correlation with increasing wind speed compared with the dynamic sampler. In the field study, the difference in efficiency between the two types of collector was fairly small. As the difference in collecting efficiency between the different types of sampler was small, the dynamic sampler was selected for further measurements of airborne drift under field conditions owing to its more well-defined collecting area. This study of collecting efficiency of airborne spray drift of static and dynamic samplers under field conditions contributes to increasing knowledge in this field of research. Copyright © 2011 Society of Chemical Industry.
1975-02-01
Hayward orange- peel sampler and with a sampler developed by Mr. Robert E. Louden, formerly of the Corps of Engineers. The sampler developed by Mr. Louden...Experimental sampler. The other samples were taken with an orange peel sampler. TESTS 4. Tests were performed as follows: a. Volatile solids, chemical oxygen...diver using an orange peel sampler. It was taken with twelve other samples, all in glass Jars, anO. was received on 20 December 1971. TESTS 4. Tests
Braccini, Matias; Van Rijn, Jay; Frick, Lorenz
2012-01-01
Most sharks, rays and chimaeras (chondrichthyans) taken in commercial fisheries are discarded (i.e. returned to the ocean either dead or alive). Quantifying the post-capture survival (PCS) of discarded species is therefore essential for the improved management and conservation of this group. For all chondrichthyans taken in the main shark fishery of Australia, we quantified the immediate PCS of individuals reaching the deck of commercial shark gillnet fishing vessels and applied a risk-based method to semi-quantitatively determine delayed and total PCS. Estimates of immediate, delayed and total PCS were consistent, being very high for the most commonly discarded species (Port Jackson shark, Australian swellshark, and spikey dogfish) and low for the most important commercial species (gummy and school sharks). Increasing gillnet soak time or water temperature significantly decreased PCS. Chondrichthyans with bottom-dwelling habits had the highest PCS whereas those with pelagic habits had the lowest PCS. The risk-based approach can be easily implemented as a standard practice of on-board observing programs, providing a convenient first-step assessment of the PCS of all species taken in commercial fisheries. PMID:22384270
Braccini, Matias; Van Rijn, Jay; Frick, Lorenz
2012-01-01
Most sharks, rays and chimaeras (chondrichthyans) taken in commercial fisheries are discarded (i.e. returned to the ocean either dead or alive). Quantifying the post-capture survival (PCS) of discarded species is therefore essential for the improved management and conservation of this group. For all chondrichthyans taken in the main shark fishery of Australia, we quantified the immediate PCS of individuals reaching the deck of commercial shark gillnet fishing vessels and applied a risk-based method to semi-quantitatively determine delayed and total PCS. Estimates of immediate, delayed and total PCS were consistent, being very high for the most commonly discarded species (Port Jackson shark, Australian swellshark, and spikey dogfish) and low for the most important commercial species (gummy and school sharks). Increasing gillnet soak time or water temperature significantly decreased PCS. Chondrichthyans with bottom-dwelling habits had the highest PCS whereas those with pelagic habits had the lowest PCS. The risk-based approach can be easily implemented as a standard practice of on-board observing programs, providing a convenient first-step assessment of the PCS of all species taken in commercial fisheries.
Mohd Din, F H; Hoe, Victor C W; Chan, C K; Muslan, M A
2015-05-01
The Pain Catastrophizing Scale (PCS) is designed to assess negative thoughts in response to pain. It is composed of three domains: helplessness, rumination, and magnification. We report on the translation, adaptation, and validation of scores on a Malay-speaking version of the PCS, the PCS-MY. Guidelines for the process of cross-cultural adaptations of assessment measures were implemented. A sample of 303 young military recruits participated in the study. Factor structure, reliability, and validity of scores on the PCS-MY were examined. Convergent validity was investigated with the Positive and Negative Affect Scale, Short-form 12 version 2, and Ryff's Psychological Well-being Scale. Most participants were men, ranging in age from 19 to 26. The reliability of the PCS-MY scores was adequate (α = 0.90; mean inter-item correlation = 0.43). Confirmatory factor analysis showed that a modified version of the PCS-MY provided best fit estimates to the sample data. The PCS-MY total score was negatively correlated with mental well-being and positively correlated with negative affect (all ps < 0.001). The PCS-MY was demonstrated to have adequate reliability and validity estimates in the study sample.
Improved prediction of MHC class I and class II epitopes using a novel Gibbs sampling approach.
Nielsen, Morten; Lundegaard, Claus; Worning, Peder; Hvid, Christina Sylvester; Lamberth, Kasper; Buus, Søren; Brunak, Søren; Lund, Ole
2004-06-12
Prediction of which peptides will bind a specific major histocompatibility complex (MHC) constitutes an important step in identifying potential T-cell epitopes suitable as vaccine candidates. MHC class II binding peptides have a broad length distribution complicating such predictions. Thus, identifying the correct alignment is a crucial part of identifying the core of an MHC class II binding motif. In this context, we wish to describe a novel Gibbs motif sampler method ideally suited for recognizing such weak sequence motifs. The method is based on the Gibbs sampling method, and it incorporates novel features optimized for the task of recognizing the binding motif of MHC classes I and II. The method locates the binding motif in a set of sequences and characterizes the motif in terms of a weight-matrix. Subsequently, the weight-matrix can be applied to identifying effectively potential MHC binding peptides and to guiding the process of rational vaccine design. We apply the motif sampler method to the complex problem of MHC class II binding. The input to the method is amino acid peptide sequences extracted from the public databases of SYFPEITHI and MHCPEP and known to bind to the MHC class II complex HLA-DR4(B1*0401). Prior identification of information-rich (anchor) positions in the binding motif is shown to improve the predictive performance of the Gibbs sampler. Similarly, a consensus solution obtained from an ensemble average over suboptimal solutions is shown to outperform the use of a single optimal solution. In a large-scale benchmark calculation, the performance is quantified using relative operating characteristics curve (ROC) plots and we make a detailed comparison of the performance with that of both the TEPITOPE method and a weight-matrix derived using the conventional alignment algorithm of ClustalW. The calculation demonstrates that the predictive performance of the Gibbs sampler is higher than that of ClustalW and in most cases also higher than that of the TEPITOPE method.
NASA Astrophysics Data System (ADS)
Goossens, Dirk; Nolet, Corjan; Etyemezian, Vicken; Duarte-Campos, Leonardo; Bakker, Gerben; Riksen, Michel
2018-06-01
Five types of sediment samplers designed to measure aeolian sand transport were tested during a wind erosion event on the Sand Motor, an area on the west coast of the Netherlands prone to severe wind erosion. Each of the samplers operates on a different principle. The MWAC (Modified Wilson And Cooke) is a passive segmented trap. The modified Leatherman sampler is a passive vertically integrating trap. The Saltiphone is an acoustic sampler that registers grain impacts on a microphone. The Wenglor sampler is an optical sensor that detects particles as they pass through a laser beam. The SANTRI (Standalone AeoliaN Transport Real-time Instrument) detects particles travelling through an infrared beam, but in different channels each associated with a particular grain size spectrum. A procedure is presented to transform the data output, which is different for each sampler, to a common standard so that the samplers can be objectively compared and their relative efficiency calculated. Results show that the efficiency of the samplers is comparable despite the differences in operating principle and the instrumental and environmental uncertainties associated to working with particle samplers in field conditions. The ability of the samplers to register the temporal evolution of a wind erosion event is investigated. The strengths and weaknesses of the samplers are discussed. Some problems inherent to optical sensors are looked at in more detail. Finally, suggestions are made for further improvement of the samplers.
Fernandes, Linda; Storheim, Kjersti; Lochting, Ida; Grotle, Margreth
2012-06-22
Pain catastrophizing has been found to be an important predictor of disability and days lost from work in patients with low back pain. The most commonly used outcome measure to identify pain catastrophizing is the Pain Catastrophizing Scale (PCS). To enable the use of the PCS in clinical settings and research in Norwegian speaking patients, the PCS had to be translated. The purpose of this study was therefore to translate and cross-culturally adapt the PCS into Norwegian and to test internal consistency, construct validity and reproducibility of the PCS. The PCS was translated before it was tested for psychometric properties. Patients with subacute or chronic non-specific low back pain aged 18 years or more were recruited from primary and secondary care. Validity of the PCS was assessed by evaluating data quality (missing, floor and ceiling effects), principal components analysis, internal consistency (Cronbach's alpha), and construct validity (Spearman's rho). Reproducibility analyses included standard error of measurement, minimum detectable change, limits of agreement, and intraclass correlation coefficients. A total of 38 men and 52 women (n = 90), with a mean (SD) age of 47.6 (11.7) years, were included for baseline testing. A subgroup of 61 patients was included for test-retest assessments. The Norwegian PCS was easy-to-comprehend. The principal components analysis supported a three-factor structure, internal consistency was satisfactory for the PCS total score (α 0.90) and the subscales rumination (α 0.83) and helplessness (α 0.86), but not for the subscale magnification (α 0.53). In total, 86% of the correlation analyses were in accordance with predefined hypothesis. The reliability analyses showed intraclass correlation coefficients of 0.74 - 0.87 for the PCS total score and subscales. The PCS total score (range 0-52 points) showed a standard error of measurement of 4.6 points and a 95% minimum detectable change estimate of 12.8 points. The Norwegian PCS total score showed acceptable psychometric properties in terms of comprehensibility, consistency, construct validity, and reproducibility when applied to patients with subacute or chronic LBP from different clinical settings. Our study support the use of the PCS total score for clinical or research purposes identifying or evaluating pain catastrophizing.
Field calibration of polyurethane foam (PUF) disk passive air samplers for PCBs and OC pesticides.
Chaemfa, Chakra; Barber, Jonathan L; Gocht, Tilman; Harner, Tom; Holoubek, Ivan; Klanova, Jana; Jones, Kevin C
2008-12-01
Different passive air sampler (PAS) strategies have been developed for sampling in remote areas and for cost-effective simultaneous spatial mapping of POPs (persistent organic pollutants) over differing geographical scales. The polyurethane foam (PUF) disk-based PAS is probably the most widely used. In a PUF-based PAS, the PUF disk is generally mounted inside two stainless steel bowls to buffer the air flow to the disk and to shield it from precipitation and light. The field study described in this manuscript was conducted to: compare performance of 3 different designs of sampler; to further calibrate the sampler against the conventional active sampler; to derive more information on field-based uptake rates and equilibrium times of the samplers. Samplers were also deployed at different locations across the field site, and at different heights up a meteorological tower, to investigate the possible influence of sampler location. Samplers deployed <5m above ground, and not directly sheltered from the wind gave similar uptake rates. Small differences in dimensions between the 3 designs of passive sampler chamber had no discernable effect on accumulation rates, allowing comparison with previously published data.
Cheng, Kuan-Chen; Catchmark, Jeff M; Demirci, Ali
2009-01-01
Bacterial cellulose has been used in the food industry for applications such as low-calorie desserts, salads, and fabricated foods. It has also been used in the paper manufacturing industry to enhance paper strength, the electronics industry in acoustic diaphragms for audio speakers, the pharmaceutical industry as filtration membranes, and in the medical field as wound dressing and artificial skin material. In this study, different types of plastic composite support (PCS) were implemented separately within a fermentation medium in order to enhance bacterial cellulose (BC) production by Acetobacter xylinum. The optimal composition of nutritious compounds in PCS was chosen based on the amount of BC produced. The selected PCS was implemented within a bioreactor to examine the effects on BC production in a batch fermentation. The produced BC was analyzed using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), thermogravimetric analysis (TGA), and dynamic mechanical analysis (DMA). Among thirteen types of PCS, the type SFYR+ was selected as solid support for BC production by A. xylinum in a batch biofilm reactor due to its high nitrogen content, moderate nitrogen leaching rate, and sufficient biomass attached on PCS. The PCS biofilm reactor yielded BC production (7.05 g/L) that was 2.5-fold greater than the control (2.82 g/L). The XRD results indicated that the PCS-grown BC exhibited higher crystallinity (93%) and similar crystal size (5.2 nm) to the control. FESEM results showed the attachment of A. xylinum on PCS, producing an interweaving BC product. TGA results demonstrated that PCS-grown BC had about 95% water retention ability, which was lower than BC produced within suspended-cell reactor. PCS-grown BC also exhibited higher Tmax compared to the control. Finally, DMA results showed that BC from the PCS biofilm reactor increased its mechanical property values, i.e., stress at break and Young's modulus when compared to the control BC. The results clearly demonstrated that implementation of PCS within agitated fermentation enhanced BC production and improved its mechanical properties and thermal stability. PMID:19630969
Pediatric palliative care consultation services in California hospitals.
Reid, Thomas; O'Riordan, David L; Mazzini, Andrea; Bruno, Kelly A; Pantilat, Steven Z
2014-12-01
The American Academy of Pediatrics recommends that palliative care be available to seriously ill hospitalized children, yet little is known about how these services are structured. The study's aim is to report the prevalence of pediatric palliative care services (PCS) and compare the structure of pediatric PCS to adult PCS within California hospitals. We surveyed 377 hospitals to assess the prevalence, structure, and characteristics of pediatric and adult PCS. Hospitals were categorized as children's hospitals with a pediatric-only PCS, mixed hospitals with pediatric and adult PCS, and hospitals with adult-only PCS. All 8 children's hospitals in the state reported having a pediatric PCS, and 36 pediatric PCSs were in mixed hospitals. Mixed hospitals saw fewer (p=0.0001) children per year (mean=5.6, standard deviation [SD]=3.6) than pediatric-only PCSs (mean=168, SD=73). Pediatric-only PCSs treated more patients for noncancer-related illness (82.5%) than pediatric PCSs in mixed hospitals (34.5%, p=0.03) or adult-only PCSs (52.4%, p=0.001). All PCSs were universally available (100%) during weekday business hours and half were available during weekend business hours. Pediatric-only PCSs had a mean total full-time equivalent (FTE) of 1.9, which was not significantly different (p=0.3) from the total FTE for pediatric PCSs in mixed hospitals (mean=1.1, SD=1.4) or for adult-only PCSs (mean=2.7, SD=2.0). However, in mixed hospitals the adult PCS had a significantly higher (p=0.005) total FTE (mean=2.4, SD=1.3) than the pediatric PCS (mean=1.1, SD=1.4). All children's hospital and a few mixed hospitals offer pediatric PCS. Better understanding of the palliative care needs of seriously ill children in mixed hospitals and assessment of the quality of care provided will help ensure that children seen in these hospitals receive necessary care.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shiba, Takahiro, E-mail: takahiro-shiba@yakult.co.jp; Kawakami, Koji; Sasaki, Takashi
2014-01-15
Protein fermentation by intestinal bacteria generates various compounds that are not synthesized by their hosts. An example is p-cresol, which is produced from tyrosine. Patients with chronic kidney disease (CKD) accumulate high concentrations of intestinal bacteria-derived p-cresyl sulfate (pCS), which is the major metabolite of p-cresol, in their blood, and this accumulation contributes to certain CKD-associated disorders. Immune dysfunction is a CKD-associated disorder that frequently contributes to infectious diseases among CKD patients. Although some studies imply pCS as an etiological factor, the relation between pCS and immune systems is poorly understood. In the present study, we investigated the immunological effectsmore » of pCS derived from intestinal bacteria in mice. For this purpose, we fed mice a tyrosine-rich diet that causes the accumulation of pCS in their blood. The mice were shown to exhibit decreased Th1-driven 2, 4-dinitrofluorobenzene-induced contact hypersensitivity response. The concentration of pCS in blood was negatively correlated with the degree of the contact hypersensitivity response. In contrast, the T cell-dependent antibody response was not influenced by the accumulated pCS. We also examined the in vitro cytokine responses by T cells in the presence of pCS. The production of IFN-γ was suppressed by pCS. Further, pCS decreased the percentage of IFN-γ-producing Th1 cells. Our results suggest that intestinal bacteria-derived pCS suppressesTh1-type cellular immune responses. - Highlights: • Mice fed a tyrosine-rich diet accumulated p-cresyl sulfate in their blood. • p-Cresyl sulfate negatively correlated with contact hypersensitivity response. • The in vitro production of IFN-γ was suppressed by p-cresyl sulfate. • p-Cresyl sulfate decreased the percentage of IFN-γ-producing Th1 cells in vitro.« less
Assessment of soil-gas contamination at the 17th Street landfill, Fort Gordon, Georgia, 2011
Falls, W. Fred; Caldwell, Andral W.; Guimaraes, Wladmir G.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2012-01-01
Assessments of contaminants in soil gas were conducted in two study areas at Fort Gordon, Georgia, in July and August of 2011 to supplement environmental contaminant data for previous studies at the 17th Street landfill. The two study areas include northern and eastern parts of the 17th Street landfill and the adjacent wooded areas to the north and east of the landfill. These study areas were chosen because of their close proximity to the surface water in Wilkerson Lake and McCoys Creek. A total of 48 soil-gas samplers were deployed for the July 28 to August 3, 2011, assessment in the eastern study area. The assessment mostly identified detections of total petroleum hydrocarbons (TPH), and gasoline- and diesel-range compounds, but also identified the presence of chlorinated solvents in six samplers, chloroform in three samplers, 2-methyl naphthalene in one sampler, and trimethylbenzene in one sampler. The TPH masses exceeded 0.02 microgram (μg) in all 48 samplers and exceeded 0.9 μg in 24 samplers. Undecane, one of the three diesel-range compounds used to calculate the combined mass for diesel-range compounds, was detected in 17 samplers and is the second most commonly detected compound in the eastern study area, exceeded only by the number of TPH detections. Six samplers had detections of toluene, but other gasoline compounds were detected with toluene in three of the samplers, including detections of ethylbenzene, meta- and para-xylene, and octane. All detections of chlorinated organic compounds had soil-gas masses equal to or less than 0.08 μg, including three detections of trichloroethene, three detections of perchloroethene, three chloroform detections, one 1,4-dichlorobenzene detection, and one 1,1,2-trichloroethane detection. Three methylated compounds were detected in the eastern study area, but were detected at or below method detection levels. A total of 32 soil-gas samplers were deployed for the August 11–24, 2011, assessment in the northern study area. All samplers in the survey had detections of TPH, but only eight of the samplers had detections of TPH greater than 0.9 mg. Four samplers had TPH detections greater than 9 mg; the only other fuel-related compounds detected in these four samplers included toluene in three of the samplers and undecane in the fourth sampler. Three samplers deployed along the western margin of the northern landfill had detections of both diesel-and gasoline-related compounds; however, the diesel-related compounds were detected at or below method detection levels. Seven samplers in the northern study area had detections of chlorinated compounds, including three perchloroethene detections, three chloroform detections, and one 1,4-dichloro-benzene detection. One sampler on the western margin of the landfill had detections of 1,2,4-trimethylbenzene and 1,3,5-tr-methylbenene below method detection levels.
Kong, Fenfen; Liu, Fei; Li, Wei; Guo, Xiaomeng; Wang, Zuhua; Zhang, Hanbo; Li, Qingpo; Luo, Lihua; Du, Yongzhong; Jin, Yi; You, Jian
2016-12-01
Near-infrared (NIR) laser-controlled gene delivery presents some benefits in gene therapy, inducing enhanced gene transfection efficiency. In this study, a "photothermal transfection" agent is obtained by wrapping poly(ethylenimine)-cholesterol derivatives (PEI-Chol) around single-walled carbon nanotubes (SWNTs). The PEI-Chol modified SWNTs (PCS) are effective in compressing DNA molecules and protecting them from DNaseI degradation. Compared to the complexes formed by PEI with DNA (PEI/DNA), complexes of PCS and DNA that are formed (PCS/DNA) exhibit a little lower toxicity to HEK293 and HeLa cells under the same PEI molecule weight and weight ratios. Notably, caveolae-mediated cellular uptake of PCS/DNA occurs, which results in a safer intracellular transport of the gene due to the decreased lysosomal degradation in comparison with that of PEI/DNA whose internalization mainly depends on clathrin rather than caveolae. Furthermore, unlike PEI/DNA, PCS/DNA exhibits a photothermal conversion ability, which promotes DNA release from PCS under NIR laser irradiation. The NIR laser-mediated photothermal transfection of PCS 10K /plasmid TP53 (pTP53) results in more apoptosis and necrosis of HeLa cells in vitro than other groups, and achieves a higher tumor-growth inhibition in vivo than naked pTP53, PEI 25K /pTP53, and PCS 10K /pTP53 alone. The enhanced transfection efficiency of PCS/DNA can be attributed to more efficient DNA internalization into the tumor cells, promotes detachment of DNA from PCS under the mediation of NIR laser and higher DNA stability in the cells due to caveolae-mediated cellular uptake of the complexes. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yanagisawa, Ryu; Shimodaira, Shigetaka; Kojima, Shunsuke; Nakasone, Nobuhiko; Ishikawa, Shinsuke; Momose, Kayo; Honda, Takayuki; Yoshikawa, Kentaro; Saito, Shoji; Tanaka, Miyuki; Nakazawa, Yozo; Sakashita, Kazuo; Shiohara, Masaaki; Akino, Mitsuaki; Hirayama, Junichi; Azuma, Hiroshi; Koike, Kenichi
2013-09-01
Allergic transfusion reactions (ATRs), particularly those caused by plasma-rich platelet concentrates (P-PCs), are an important concern in transfusion medicine. Replacing P-PCs with PCs containing M-sol (M-sol-R-PCs) is expected to prevent ATRs. However, this has not yet been verified by sufficient clinical evidence. A retrospective cohort study was performed between 2008 and 2011. Pediatric patients with hematologic disorders, solid tumors, primary immunodeficiency disorders, or inherited metabolic disorders were transfused with M-sol-R-PCs between 2010 and 2011; the transfusions of P-PCs administered between 2008 and 2011 were compared in terms of frequency and severity of ATRs, corrected count increment (CCI), and occurrence of bleeding. Data were collected for 6 consecutive months on a per-patient basis. Data obtained during 2008 to 2011 showed that of the 78 patients receiving 515 P-PC transfusions, 14 (17.9%) had 17 ATRs (3.3%); 14 and three ATRs were of Grades 1 and 2, respectively. In 2010 to 2011, 49 patients received 620 transfusions of M-sol-R-PCs, and two patients (4.1%) had Grade 1 ATRs (0.3%). Thus, the frequency of ATRs per bag and per patient differed significantly between the two transfusions. No steroid agents were used for the prevention or treatment of ATRs in the M-sol-R-PC group. The CCI (24 hr) for M-sol-R-PCs did not differ from that for P-PCs. M-sol-R-PCs were found to be effective in preventing ATRs without loss of transfusion efficiency in children; however, its efficacy should be further evaluated in prospective clinical trials. © 2012 American Association of Blood Banks.
Singh, Sukhi; Shams Hakimi, Caroline; Jeppsson, Anders; Hesse, Camilla
2017-12-01
Platelet storage lesion is characterized by morphological changes and impaired platelet function. The collection method and storage medium may influence the magnitude of the storage lesion. The aim of this study was to compare the newly introduced interim platelet unit (IPU) platelet concentrates (PCs) (additive solution SSP+, 40% residual plasma content) with the more established buffy-coat PCs (SSP, 20% residual plasma content) and apheresis PCs (autologous plasma) in terms of platelet storage lesions. Thirty PCs (n=10 for each type) were assessed by measuring metabolic parameters (lactate, glucose, and pH), platelet activation markers, and in vitro platelet aggregability on days 1, 4, and 7 after donation. The expression of platelet activation markers CD62p (P-selectin), CD63 (LAMP-3), and phosphatidylserine was measured using flow cytometry and in vitro aggregability was measured with multiple electrode aggregometry. Higher platelet activation and lower in vitro aggregability was observed in IPU than in buffy-coat PCs on day 1 after donation. In contrast, metabolic parameters, expression of platelet activation markers, and in vitro aggregability were better maintained in IPU than in buffy-coat PCs at the end of the storage period. Compared to apheresis PCs, IPU PCs had higher expression of activation markers and lower in vitro aggregability throughout storage. In conclusion, the results indicate that there are significant differences in platelet storage lesions between IPU, buffy-coat, and apheresis PCs. The quality of IPU PCs appears to be at least comparable to buffy-coat preparations. Further studies are required to distinguish the effect of the preparation methods from storage conditions. Copyright © 2017 Elsevier Ltd. All rights reserved.
Nilsson, Andreas; Steinvall, Ingrid; Bak, Zoltan; Sjöberg, Folke
2008-11-01
Patient controlled sedation (PCS) enables patients to titrate doses of drugs by themselves during different procedures involving pain or discomfort. We studied it in a prospective crossover design using a fixed protocol without lockout time to examine it as an alternative method of sedation for changing dressings in burned patients. Eleven patients with >10% total burn surface area (TBSA) had their dressings changed, starting with sedation by an anaesthetist (ACS). The second dressing change was done with PCS (propofol/alfentanil) and the third time the patients had to choose ACS or PCS. During the procedures, data on cardiopulmonary variables, sedation (bispectral index), pain intensity (VAS), procedural details, doses of drugs, and patients' preferences were collected to compare the two sedation techniques. The study data indicated that wound care in burned patients is feasible with a standardized PCS protocol. The patients preferred PCS to ACS on the basis of self-control, and because they had less discomfort during the recovery period. Wound care was also considered adequate by the staff during PCS. No respiratory (respiratory rate/transcutaneous PCO(2)) or cardiovascular (heart rate/blood pressure) adverse events were recorded at any time during any of the PCS procedures. The doses of propofol and alfentanil and BIS index decrease were less during PCS than ACS. Procedural pain was higher during PCS but lower after the procedure. We suggest that PCS using a standard protocol is an interesting alternative to anaesthetist-provided sedation during dressing changes. It seems effective, saves resources, is safe, and at same time is preferred by the patients. The strength of these conclusions is, however, hampered by the small size of this investigation and therefore further studies are warranted.
An assessment of the variability in performance of wet atmospheric deposition samplers
Graham, R.C.; Robertson, J.K.; Obal, John
1987-01-01
The variability in performance of two brands of wet/dry atmospheric deposition samplers were compared for 1 year at a sincle site. A total of nine samplers were used. Samples were collected weekly and analyzed for pH, specific conductance, common chemical constituents, and sample volume. Additionally, data on the duration of each sampler opening were recorded using a microdatalogger. These data disprove the common perception that samplers remain open throughout a precipitation event. The sensitivity of sampler sensors within the range tested did not have a defineable impact on sample collection. The nonnormal distribution within the data set necessitated application of the nonparametric Friedman Test to assess comparability of sample chemical composition and volume between and within sampler brands. Statistically significant differences existed for most comparisons, however the test did not permit quantification of their magnitudes. Differences in analyte concentrations between samplers were small. (USGS)
Evaluation of various soil water samplers for virological sampling.
Wang, D S; Lance, J C; Gerba, C P
1980-01-01
Two commercially available soil water samplers and a ceramic sampler constructed in our laboratories were evaluated for their ability to recover viruses from both tap water and secondary sewage effluent. The ceramic sampler consistently gave the best recoveries of viruses from water samples. Soil columns containing ceramic samplers at various depths provide a simple method for studying virus transport through sewage-contaminated soils. Images PMID:6247976
Acute toxicity and anti-fatigue activity of polysaccharide-rich extract from corn silk.
Zhao, He-Peng; Zhang, Yang; Liu, Zhuo; Chen, Jiang-Yue; Zhang, Song-Yan; Yang, Xiu-Dong; Zhou, Hong-Li
2017-06-01
The aim of this study was to evaluate the safety and potential of PCS as the anti-fatigue functional food. PCS was prepared by water extracting-alcohol precipitating method, and its chemical compositions of monosaccharide were analyzed. Then, acute toxicity and anti-fatigue activity of PCS were evaluated. PCS is composed of Rha, Arab, Xyl, Man, Glu, and Gal, its molar ratio is 0.17: 0.30: 0.26: 0.35: 1.00: 0.57. No mortality and general symptoms of toxicity were observed in the PCS treated mice (7.5, 15, and 20g/kg body weight), the body weight and food consumption were not significantly changed compared with the normal control group. The relative weights of main organ, and biochemical indicators also did not markedly change. PCS can significantly prolong the duration of the swimming time to exhaustion in mice, decrease BUN, LA levels, increase LDH activities, and the contents of HG in the PCS treated mice. The dose of 400mg/kg body weight is the optimal dose for anti-fatigue activity both in male and female mice. In conclusion, PCS is a promising traditional natural-based therapeutic remedy for relieving fatigue with high safety. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Bianchi, Giada; Kyle, Robert A.; Larson, Dirk R.; Witzig, Thomas E.; Kumar, Shaji; Dispenzieri, Angela; Morice, William G.; Rajkumar, S. Vincent
2012-01-01
Smoldering multiple myeloma (SMM) carries a 50% risk of progression to multiple myeloma (MM) or related malignancy within the first 5 years following diagnosis. The goal of this study was to determine if high levels of circulating plasma cells (PCs) are predictive of SMM transformation within the first 2–3 years from diagnosis. Ninety-one patients diagnosed with SMM at Mayo Clinic from January 1994 through January 2007 who had testing for circulating PCs using an immunofluorescent assay and adequate follow up to ascertain disease progression, were studied. High level of circulating PCs was defined as absolute peripheral blood PCs >5000 ×106/L and/or > 5% cytoplasmic immunoglobulin (Ig) positive PCs per 100 peripheral blood mononuclear cells. Patients with high circulating PCs (14 of 91 patients, 15%) were significantly more likely to progress to active disease within 2 years compared with patients without high circulating PCs, 71% versus 25%, respectively, P=0.001. Corresponding rates for progression within 3 years were 86% versus 35%, respectively, P<0.001. Overall survival (OS) after both SMM diagnosis and MM diagnosis was also significantly different. High levels of circulating PCs identify SMM patients with an elevated risk of progression within the first 2 to 3 years following diagnosis. PMID:22902364
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chaurasia, Neha; Mishra, Yogesh; Rai, Lal Chand
Phytochelatin synthase (PCS) is involved in the synthesis of phytochelatins (PCs), plays role in heavy metal detoxification. The present study describes for first time the functional expression and characterization of pcs gene of Anabaena sp. PCC 7120 in Escherichia coli in terms of offering protection against heat, salt, carbofuron (pesticide), cadmium, copper, and UV-B stress. The involvement of pcs gene in tolerance to above abiotic stresses was investigated by cloning of pcs gene in expression vector pGEX-5X-2 and its transformation in E. coli BL21 (DE3). The E. coli cells transformed with pGEX-5X-pcs showed better growth than control cells (pGEX-5X-2) undermore » temperature (47 deg. C), NaCl (6% w/v), carbofuron (0.025 mg ml{sup -1}), CdCl{sub 2} (4 mM), CuCl{sub 2} (1 mM), and UV-B (10 min) exposure. The enhanced expression of pcs gene revealed by RT-PCR analysis under above stresses at different time intervals further advocates its role in tolerance against above abiotic stresses.« less
Zhao, Chun-Fang; Lei, Dou Jian; Song, Guang Hao; Zhang, Hua; Xu, Hang; Yu, Long-Jiang
2015-02-15
Proanthocyanidins (PCs) with poor bioavailability were argued for their health benefits. In this study, water-soluble polymeric polyphenolic PCs fractions from Pyracanthafortuneana fruit were used to investigate whether the presence of PCs is correlated with the increased cell antioxidant activities (CAA) of quercetin (Q). The results indicated that the most decrement in the values of EC50, which Q inhibited peroxyl radical-induced DCFH oxidation effective in the HepG2 cells, was observed to be 2.91 (vs. control 5.97) in the present of the fraction with 15.8 of the average degree of polymerisation of PCs (ADP). Also, the order of efficacy was the same with the ADP of PCs. Further, this effect is associated with the improvement of the solubility and stability of Q after the addition of the PCs. Our current study suggests that the additive effects of PCs on small molecular polyphenols may be responsible for their antioxidant benefits in vivo. Copyright © 2014 Elsevier Ltd. All rights reserved.
The evolution and impact of PCS technology
NASA Astrophysics Data System (ADS)
Lawson, John R.
1994-09-01
In today's mobile society, communications services that focus on location (wired) are increasingly inadequate. But services that center around the individual (wireless) are being developed to serve society in a way that only recently could consumers have imagined. People-oriented communications tools will make life simpler and more productive. The essence of this concept is captured in a family of wireless services and devices that allow the user to communicate independent of location--Personal Communications Services, known as PCS. First generation PCS devices such a pagers and cellular phones were the instruments of the first wireless revolution, but they will soon be forced to relinquish the spotlight to the new generation of PCS and what should be a dazzling variety of individualized advanced telecommunications services and devices. Within the next two years, these new PCS models, recently described as 'the most exciting development in telecommunications since the breakup of AT&T,' should hit the marketplace, changing the way we communicate and, in turn, the way we live. This paper explores the status and likely development of PCS generally, including 'new PCS.'
A wind tunnel test of newly developed personal bioaerosol samplers.
Su, Wei-Chung; Tolchinsky, Alexander D; Sigaev, Vladimir I; Cheng, Yung Sung
2012-07-01
In this study the performance of two newly developed personal bioaerosol samplers was evaluated. The two test samplers are cyclone-based personal samplers that incorporate a recirculating liquid film. The performance evaluations focused on the physical efficiencies that a personal bioaerosol sampler could provide, including aspiration, collection, and capture efficiencies. The evaluation tests were carried out in a wind tunnel, and the test personal samplers were mounted on the chest of a full-size manikin placed in the test chamber of the wind tunnel. Monodisperse fluorescent aerosols ranging from 0.5 to 20 microm were used to challenge the samplers. Two wind speeds of 0.5 and 2.0 m/sec were employed as the test wind speeds in this study. The test results indicated that the aspiration efficiency of the two test samplers closely agreed with the ACGIH inhalable convention within the size range of the test aerosols. The aspiration efficiency was found to be independent of the sampling orientation. The collection efficiency acquired from these two samplers showed that the 50% cutoff diameters were both around 0.6 microm. However the wall loss of these two test samplers increased as the aerosol size increased, and the wall loss of PAS-4 was considerably higher than that of PAS-5, especially in the aerosol size larger than 5 microm, which resulted in PAS-4 having a relatively lower capture efficiency than PAS-5. Overall, the PAS-5 is considered a better personal bioaerosol sampler than the PAS-4.
Development and evaluation of a water level proportional water sampler
NASA Astrophysics Data System (ADS)
Schneider, P.; Lange, A.; Doppler, T.
2013-12-01
We developed and adapted a new type of sampler for time-integrated, water level proportional water quality sampling (e.g. nutrients, contaminants and stable isotopes). Our samplers are designed for sampling small to mid-size streams based on the law of Hagen-Poiseuille, where a capillary (or a valve) limits the sampling aliquot by reducing the air flux out of a submersed plastic (HDPE) sampling container. They are good alternatives to battery-operated automated water samplers when working in remote areas, or at streams that are characterized by pronounced daily discharge variations such as glacier streams. We evaluated our samplers against standard automated water samplers (ISCO 2900 and ISCO 6712) during the snowmelt in the Black Forest and the Alps and tested them in remote glacial catchments in Iceland, Switzerland and Kyrgyzstan. The results clearly showed that our samplers are an adequate tool for time-integrated, water level proportional water sampling at remote test sites, as they do not need batteries, are relatively inexpensive, lightweight, and compact. They are well suited for headwater streams - especially when sampling for stable isotopes - as the sampled water is perfectly protected against evaporation. Moreover, our samplers have a reduced risk of icing in cold environments, as they are installed submersed in water, whereas automated samplers (typically installed outside the stream) may get clogged due to icing of hoses. Based on this study, we find these samplers to be an adequate replacement for automated samplers when time-integrated sampling or solute load estimates are the main monitoring tasks.
Molecular comparison of the sampling efficiency of four types of airborne bacterial samplers.
Li, Kejun
2011-11-15
In the present study, indoor and outdoor air samples were collected using four types of air samplers often used for airborne bacterial sampling. These air samplers included two solid impactors (BioStage and RCS), one liquid impinger (BioSampler), and one filter sampler with two kinds of filters (a gelatin and a cellulose acetate filter). The collected air samples were further processed to analyze the diversity and abundance of culturable bacteria and total bacteria through standard culture techniques, denaturing gradient gel electrophoresis (DGGE) fingerprinting and quantitative polymerase chain reaction (qPCR) analysis. The DGGE analysis indicated that the air samples collected using the BioStage and RCS samplers have higher culturable bacterial diversity, whereas the samples collected using the BioSampler and the cellulose acetate filter sampler have higher total bacterial diversity. To obtain more information on the sampled bacteria, some gel bands were excised and sequenced. In terms of sampling efficiency, results from the qPCR tests indicated that the collected total bacterial concentration was higher in samples collected using the BioSampler and the cellulose acetate filter sampler. In conclusion, the sampling bias and efficiency of four kinds of air sampling systems were compared in the present study and the two solid impactors were concluded to be comparatively efficient for culturable bacterial sampling, whereas the liquid impactor and the cellulose acetate filter sampler were efficient for total bacterial sampling. Copyright © 2011 Elsevier B.V. All rights reserved.
Evaluation of three portable samplers for monitoring airborne fungi
NASA Technical Reports Server (NTRS)
Mehta, S. K.; Mishra, S. K.; Pierson, D. L.
1996-01-01
Airborne fungi were monitored at five sample sites with the Burkard portable, the RCS Plus, and the SAS Super 90 air samplers; the Andersen 2-stage impactor was used for comparison. All samplers were calibrated before being used simultaneously to collect 100-liter samples at each site. The Andersen and Burkard samplers retrieved equivalent volumes of airborne fungi; the SAS Super 90 and RCS Plus measurements did not differ from each other but were significantly lower than those obtained with the Andersen or Burkard samplers. Total fungal counts correlated linearly with Cladosporium and Penicillium counts. Alternaria species, although present at all sites, did not correlate with total count or with amounts of any other fungal genera. Sampler and location significantly influenced fungal counts, but no interactions between samplers and locations were found.
Performance evaluation of a tailor-made passive sampler for monitoring of tropospheric ozone.
Ozden, Ozlem; Döğeroğlu, Tuncay
2012-09-01
This study presents the performance evaluation of a tailor-made passive sampler developed for the monitoring of tropospheric ozone. The performance of the passive sampler was tested in the field conditions in terms of accuracy, precision, blank values, detection limit, effects of some parameters such as sampling site characteristics and sampling period on the field blanks, self-consistency, experimental and theoretical uptake rates, shelf life and comparison with commercial passive samplers. There was an agreement (R (2) = 0.84) between the responses of passive sampler and the continuous automatic analyser. The accuracy of the sampler, expressed as percent relative error, was obtained lower than 15%. Method precision in terms of coefficient of variance for three simultaneously applied passive samplers was 12%. Sampler detection limit was 2.42 μg m(-3) for an exposure period of 1 week, and the sampler can be stored safely for a period of up to 8 weeks before exposure. Satisfactory self-consistency results showed that extended periods gave the same integrated response as a series of short-term samplers run side by side. The uptake rate of ozone was found to be 10.21 mL min(-1) in a very good agreement with the theoretical uptake rate (10.32 mL min(-1)). The results of the comparison study conducted against a commercially available diffusion tube (Gradko diffusion tube) showed a good linear relationship (R (2) = 0.93) between two passive samplers. The sampler seems suitable to be used in large-scale measurements of ozone where no data are available or the number of existing automated monitors is not sufficient.
Development Of An In Situ Passive Sampler For The Detection And Remediation of Explosive Compounds
2016-06-07
FINAL REPORT Development of an In Situ Passive Sampler for the Detection and Remediation of Explosive Compounds SERDP Project ER-2539 MAY 2016...DATES COVERED (From - To) 4/24/15 – 12/1/2016 4. TITLE AND SUBTITLE Development of an In Situ Passive Sampler for the Detection and Remediation of...SUBJECT TERMS Passive samplers, Ethylene vinyl acetate, EVA sampler, Munitions, Monitoring, Remediation , Marine, Sediments 16. SECURITY
Vollmer, T; Dreier, J; Schottstedt, V; Bux, J; Tapernon, K; Sibrowski, W; Kleesiek, K; Knabbe, C
2012-08-01
Bacterial contamination of platelet concentrates (PCs) still represents an ongoing risk. As a result of septic complications, particularly observed with older PCs, the shelf life of PCs has been reduced in Germany to 4 days. In this study, bacterial screening of PCs by BactiFlow (BF) flow cytometry was introduced in three German blood services to evaluate the robustness and applicability of the assay. Results were used to discuss the potential for the extension of PC shelf life to 5 days. A total of 1956 PCs were tested on days 4 or 5+ after PC production using the BF, whereas the BacT/Alert culture system served as reference method. Two PCs were confirmed positive by culture only and were identified as Propionibacterium acnes and Staphylococcus species. Two PCs were confirmed positive for Streptococcus mitis by BF and culture. Additionally, two PCs were culture-positive only in one culture bottle (aerobic: S. mitis and anaerobic: S. hominis). Retrospective analysis of bacterial growth kinetics provide the indication that corresponding bacterial titres were most likely below the BF analytical detection limit (<150 CFU mL(-1) ) and had probably no transfusion relevance. All remaining specimens were tested negative. Testing of PCs by BF was successfully implemented. The BF proved sufficient as a rapid screening method to improve PC safety. This study further provides data supporting the extension of PC shelf life to 5 days after negative BF testing on day 4. © 2012 The Authors. Transfusion Medicine © 2012 British Blood Transfusion Society.
Williams, Randi M; Zincke, Nicole L; Turner, Ralph O; Davis, Jackson L; Davis, Kimberly M; Schwartz, Marc D; Johnson, Lenora; Kerner, Jon F; Taylor, Kathryn L
2008-10-01
Shared decision making (SDM) is recommended as one method to assist men in making an informed decision about prostate cancer screening (PCS). SDM preferences for PCS have not been evaluated among African-American (AA) men. Given AA men's increased risk and the uncertainty surrounding screening, it is critical to determine how to assist AA men in making an informed decision. We assessed the extent to which a sample of AA men wished to engage in SDM regarding PCS and the demographic and psychological characteristics associated with SDM preferences. Participants completed a telephone interview that covered demographic and medical information, SDM preferences, PCS knowledge, decisional conflict, and satisfaction with previous screening decisions. Subjects included 286 AA men aged 40-70, who were members of a Masonic organization. Fifty-seven percent preferred SDM, 36% preferred to make their own decision, and 7% wanted their doctor to decide. A higher level of education and older age were associated with preferring SDM (p<0.05), while men with greater PCS knowledge were more likely to prefer to make the decision independently (p<0.05). Results suggest that physicians need to be prepared to discuss PCS with their patients. Further, more attention may be needed to engage younger, less educated, and less knowledgeable men as they may be less likely to discuss PCS. This understanding of AA men's preferences for PCS decisions helps to clarify the issues that health professionals need to consider when attempting to assist AA men in making a PCS decision. Copyright (c) 2008 John Wiley & Sons, Ltd.
Nishigami, Tomohiko; Mibu, Akira; Tanaka, Katsuyoshi; Yamashita, Yuh; Watanabe, Akihisa; Tanabe, Akihito
2017-03-01
The Pain Catastrophizing Scale (PCS) is a commonly used as measure of pain catastrophizing. The scale comprises 13 items related to magnification, rumination, and helplessness. To facilitate quick screening and to reduce participant's burden, the four-item and six-item short forms of the English version of the PCS were developed. The purpose of the present study was to evaluate the psychometric properties of a Japanese version of the short forms of PCS using a contemporary approach called Rasch analysis. A total of 216 patients with musculoskeletal disorders were recruited in this study. Participants completed study measures, which included the pain intensity, the Pain Catastrophizing Scale (PCS), and the Tampa Scale of Kinesiophobia (TSK). Furthermore, the four-item (items 3, 6, 8, and 11) and six-item (items 4, 5, 6, 10, 11, and 13) short forms of the Japanese version of PCS were measured. We used Rasch analysis to analyze the psychometric properties of the original, four-item, and six-item short forms of PCS. Rasch analysis showed that both short forms of PCS had acceptable internal consistency, unidimensionality, and no notable DIF and were functional on the category rating scale. However, four-item short form of PCS had two misfit items. Six-item short form of PCS has acceptable psychometric properties and is suitable for use in participants with musculoskeletal pain. Thus, six-item can be used as brief instruments to evaluate pain catastrophizing. Copyright © 2016 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
Considerations for sampling inorganic constituents in ground water using diffusion samplers
Vroblesky, D.A.; Petkewich, M.D.; Campbell, T.R.; ,
2002-01-01
Data indicate that nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water from wells that closely correspond to concentrations obtained by low-flow sampling. Conservative solutes, such as chloride, can be sampled by filling the diffusion samplers with oxygenated water. The samplers should be filled with anaerobic water for sampling redoxsensitive solutes. Oxidation of iron within the samplers, either by using aerobic fill water or by in-well oxygenation events, can lead to erroneous iron concentrations. Lithologic and chemical heterogeneity and sampler placement depth can lead to differences between concentrations from diffusion samples and low-flow samples because of mixing during pumping. A disadvantage of regenerated cellulose dialysis samplers is that they can begin to biodegrade within the two weeks of deployment. Nylon-screen samplers buried beneath streambed sediment along the unnamed tributary in a discharge zone of arseniccontaminated ground water were useful in locating the specific discharge zone.
Passive air sampling theory for semivolatile organic compounds.
Bartkow, Michael E; Booij, Kees; Kennedy, Karen E; Müller, Jochen F; Hawker, Darryl W
2005-07-01
The mathematical modelling underlying passive air sampling theory can be based on mass transfer coefficients or rate constants. Generally, these models have not been inter-related. Starting with basic models, the exchange of chemicals between the gaseous phase and the sampler is developed using mass transfer coefficients and rate constants. Importantly, the inter-relationships between the approaches are demonstrated by relating uptake rate constants and loss rate constants to mass transfer coefficients when either sampler-side or air-side resistance is dominating chemical exchange. The influence of sampler area and sampler volume on chemical exchange is discussed in general terms and as they relate to frequently used parameters such as sampling rates and time to equilibrium. Where air-side or sampler-side resistance dominates, an increase in the surface area of the sampler will increase sampling rates. Sampling rates are not related to the sampler/air partition coefficient (K(SV)) when air-side resistance dominates and increase with K(SV) when sampler-side resistance dominates.
Predictors of postconcussion syndrome in collegiate student-athletes.
Zuckerman, Scott L; Yengo-Kahn, Aaron M; Buckley, Thomas A; Solomon, Gary S; Sills, Allen K; Kerr, Zachary Y
2016-04-01
OBJECTIVE Sport-related concussion (SRC) has emerged as a public health problem, especially among student-athletes. Whereas most concussions resolve by 2 weeks, a minority of patients experience postconcussion syndrome (PCS), in which symptoms persist for months. The objective of this study was to elucidate factors predictive of PCS among a sample of National Collegiate Athletic Association (NCAA) student-athletes in the academic years 2009-2010 to 2014-2015. METHODS The SRC data originated from the NCAA Injury Surveillance Program (ISP) in the 2009-2010 to 2014-2015 academic seasons. The NCAA ISP is a prospective database made up of a convenience sample of schools across all divisions. All SRCs are reported by certified athletic trainers. The PCS group consisted of concussed student-athletes with concussion-related symptoms that lasted ≥ 4 weeks. The non-PCS group consisted of concussed student-athletes with symptom resolution in ≤ 2 weeks. Those with symptoms that resolved in the intermediate area of 2-4 weeks were excluded. Odds ratios (ORs) were estimated using logistic regression. RESULTS During the 2009-2010 to 2014-2015 seasons, 1507 NCAA student-athletes sustained an SRC, 112 (7.4%) of whom developed PCS (i.e., concussion-related symptoms that lasted ≥ 4 weeks). Men's ice hockey contributed the largest proportion of concussions to the PCS group (28.6%), whereas men's football contributed the largest proportion of concussions in the non-PCS group (38.6%). In multivariate analysis, recurrent concussion was associated with increased odds of PCS (OR 2.08, 95% CI 1.28-3.36). Concussion symptoms that were also associated with increased odds of PCS included retrograde amnesia (OR 2.75, 95% CI 1.34-5.64), difficulty concentrating (OR 2.35, 95% CI 1.23-4.50), sensitivity to light (OR 1.97, 95% CI 1.09-3.57), and insomnia (OR 2.19, 95% CI 1.30-3.68). Contact level, sex, and loss of consciousness were not associated with PCS. CONCLUSIONS Postconcussion syndrome represents one of the most impactful sequelae of SRC. In this study of exclusively collegiate student-athletes, the authors found that recurrent concussions and various concussion-related symptoms were associated with PCS. The identification of initial risk factors for the development of PCS may assist sports medicine clinicians in providing timely interventions and treatments to prevent morbidity and shorten recovery time after SRC.
Shirdel, Mariam; Andersson, Britt M; Bergdahl, Ingvar A; Sommar, Johan N; Wingfors, Håkan; Liljelind, Ingrid E
2018-03-12
In an occupational environment, passive sampling could be an alternative to active sampling with pumps for sampling of dust. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). It is often analysed by microscopic imaging. Promising results have been shown for particles above 2.5 µm, but indicate large underestimations for PM2.5. The aim of this study was to evaluate, and possibly improve, the UNC sampler for stationary sampling in a working environment. Sampling was carried out at 8-h intervals during 24 h in four locations in an open pit mine with UNC samplers, respirable cyclones, PM10 and PM2.5 impactors, and an aerodynamic particle sizer (APS). The wind was minimal. For quantification, two modifications of the UNC sampler analysis model, UNC sampler with hybrid model and UNC sampler with area factor, were compared with the original one, UNC sampler with mesh factor derived from wind tunnel experiments. The effect of increased resolution for the microscopic imaging was examined. Use of the area factor and a higher resolution eliminated the underestimation for PM10 and PM2.5. The model with area factor had the overall lowest deviation versus the impactor and the cyclone. The intraclass correlation (ICC) showed that the UNC sampler had a higher precision and better ability to distinguish between different exposure levels compared to the cyclone (ICC: 0.51 versus 0.24), but lower precision compared to the impactor (PM10: 0.79 versus 0.99; PM2.5: 0.30 versus 0.45). The particle size distributions as calculated from the different UNC sampler analysis models were visually compared with the distributions determined by APS. The distributions were obviously different when the UNC sampler with mesh factor was used but came to a reasonable agreement when the area factor was used. High resolution combined with a factor based on area only, results in no underestimation of small particles compared to impactors and cyclones and a better agreement with the APS's particle size distributions. The UNC sampler had lower precision than the impactors, but higher than the respirable cyclone. The UNC sampler with area factor could be used for PM2.5, PM10 and respirable fraction measurements in this working environment without wind.
Shirdel, Mariam; Andersson, Britt M; Bergdahl, Ingvar A; Sommar, Johan N; Wingfors, Håkan; Liljelind, Ingrid E
2018-01-01
Abstract Objectives In an occupational environment, passive sampling could be an alternative to active sampling with pumps for sampling of dust. One passive sampler is the University of North Carolina passive aerosol sampler (UNC sampler). It is often analysed by microscopic imaging. Promising results have been shown for particles above 2.5 µm, but indicate large underestimations for PM2.5. The aim of this study was to evaluate, and possibly improve, the UNC sampler for stationary sampling in a working environment. Methods Sampling was carried out at 8-h intervals during 24 h in four locations in an open pit mine with UNC samplers, respirable cyclones, PM10 and PM2.5 impactors, and an aerodynamic particle sizer (APS). The wind was minimal. For quantification, two modifications of the UNC sampler analysis model, UNC sampler with hybrid model and UNC sampler with area factor, were compared with the original one, UNC sampler with mesh factor derived from wind tunnel experiments. The effect of increased resolution for the microscopic imaging was examined. Results Use of the area factor and a higher resolution eliminated the underestimation for PM10 and PM2.5. The model with area factor had the overall lowest deviation versus the impactor and the cyclone. The intraclass correlation (ICC) showed that the UNC sampler had a higher precision and better ability to distinguish between different exposure levels compared to the cyclone (ICC: 0.51 versus 0.24), but lower precision compared to the impactor (PM10: 0.79 versus 0.99; PM2.5: 0.30 versus 0.45). The particle size distributions as calculated from the different UNC sampler analysis models were visually compared with the distributions determined by APS. The distributions were obviously different when the UNC sampler with mesh factor was used but came to a reasonable agreement when the area factor was used. Conclusions High resolution combined with a factor based on area only, results in no underestimation of small particles compared to impactors and cyclones and a better agreement with the APS’s particle size distributions. The UNC sampler had lower precision than the impactors, but higher than the respirable cyclone. The UNC sampler with area factor could be used for PM2.5, PM10 and respirable fraction measurements in this working environment without wind. PMID:29300818
Long, Miao; Liu, Yi; Cao, Yu; Wang, Nan; Dang, Meng; He, Jianbin
2016-01-01
Lead is harmful for human health and animals. Proanthocyanidins (PCs), a natural antioxidant, possess a broad spectrum of pharmacological and medicinal properties. However, its protective effects against lead-induced liver damage have not been clarified. This study was aimed to evaluate the protective effect of PCs on the hepatotoxicity of male Kunming mice induced by chronic lead exposure. A total of 70 healthy male Kunming mice were averagely divided into four groups: control group, i.e., the group exposed to lead, the group treated with PCs, and the group co-treated with lead and PCs. The mice exposed to lead were given water containing 0.2% lead acetate. Mice treated in the PCs and PCs lead co-treated groups were given PC (100 mg/kg) in 0.9% saline by oral gavage. Lead exposure caused a significant elevation in the liver function parameters, lead level, lipid peroxidation, and inhibition of antioxidant enzyme activities. The induction of oxidative stress and histological alterations in the liver were minimized by co-treatment with PCs. Meanwhile, the number of Transferase-Mediated Deoxyuridine Triphosphate-Biotin Nick End Labeling (TUNEL)-positive cells was significantly reduced in the PCs/lead co-treated group compared to the lead group. In addition, the lead group showed an increase in the expression level of Bax, while the expression of Bcl-2 was decreased. Furthermore, the lead group showed an increase in the expression level of endoplasmic reticulum (ER) stress-related genes and protein (GRP78 and CHOP). Co-treated with PCs significantly reversed these expressions in the liver. PCs were, therefore, demonstrated to have protective, antioxidant, and anti-ER stress and anti-apoptotic activities in liver damage caused by chronic lead exposure in the Kunming mouse. This may be due to the ability of PCs to enhance the ability of liver tissue to protect against oxidative stress via the Nrf2/ARE signaling pathway, resulting in decreasing ER stress and apoptosis of liver tissue. PMID:27775649
7 CFR 801.5 - Tolerance for diverter-type mechanical samplers.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 7 2010-01-01 2010-01-01 false Tolerance for diverter-type mechanical samplers. 801.5 Section 801.5 Agriculture Regulations of the Department of Agriculture (Continued) GRAIN INSPECTION... mechanical samplers. The maintenance tolerance for diverter-type mechanical samplers (primary, or primary and...
2009-01-01
the rotating impactors were measured via spectroscopy and microscopy. The rotary impactors were colocated with an isokinetic air sampler for a total...diameter, and the 90% diameter (DV10 and DV90; ASTM 2004). For each replication, an isokinetic air sampler and rotary sampler operated simultaneously in the...working area of the dispersion tunnel. The isokinetic sampler (StaplexH Model TFIA High Volume Air Sampler, The Staplex Company, Brooklyn, NY) was
Evaluation of air samplers and filter materials for collection and recovery of airborne norovirus.
Uhrbrand, K; Koponen, I K; Schultz, A C; Madsen, A M
2018-04-01
The aim of this study was to identify the most efficient sampling method for quantitative PCR-based detection of airborne human norovirus (NoV). A comparative experiment was conducted in an aerosol chamber using aerosolized murine norovirus (MNV) as a surrogate for NoV. Sampling was performed using a nylon (NY) filter in conjunction with four kinds of personal samplers: Gesamtstaubprobenahme sampler (GSP), Triplex-cyclone sampler (TC), 3-piece closed-faced Millipore cassette (3P) and a 2-stage NIOSH cyclone sampler (NIO). In addition, sampling was performed using the GSP sampler with four different filter types: NY, polycarbonate (PC), polytetrafluoroethylene (PTFE) and gelatine (GEL). The sampling efficiency of MNV was significantly influenced by both sampler and filter type. The GSP sampler was found to give significantly (P < 0·05) higher recovery of aerosolized MNV than 3P and NIO. A higher recovery was also found for GSP compared with TC, albeit not significantly. Finally, recovery of aerosolized MNV was significantly (P < 0·05) higher using NY than PC, PTFE and GEL filters. The GSP sampler combined with a nylon filter was found to be the best method for personal filter-based sampling of airborne NoV. The identification of a suitable NoV air sampler is an important step towards studying the association between exposure to airborne NoV and infection. © 2017 The Society for Applied Microbiology.
Vroblesky, Don A.; Petkewich, Matthew D.; Campbell, Ted R.
2002-01-01
Field tests were performed on two types of diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. Nylon-screen samplers and dialysis samplers were tested for the collection of arsenic, calcium, chloride, iron, manganese, sulfate, and dissolved oxygen. The investigations were conducted at the Naval Industrial Reserve Ordnance Plant (NIROP), Fridley, Minnesota, and at the Naval Air Station Fort Worth Joint Reserve Base (NAS Fort Worth JRB), Texas. Data indicate that, in general, nylon-screen and dialysis diffusion samplers are capable of obtaining concentrations of inorganic solutes in ground water that correspond to concentrations obtained by low-flow sampling. Diffusion samplers offer a potentially time-saving approach to well sampling. Particular care must be taken, however, when sampling for iron and other metals, because of the potential for iron precipitation by oxygenation and when dealing with chemically stratified sampling intervals. Simple nylon-screen jar samplers buried beneath creekbed sediment appear to be effective tools for locating discharge zones of arsenic contaminated ground water. Although the LDPE samplers have proven to be inexpensive and simple to use in wells, they are limited by their inability to provide a representative sample of ionic solutes. The success of nylon-screen samplers in sediment studies suggests that these simple samplers may be useful for collecting water samples for inorganic constituents in wells. Results using dialysis bags deployed in wells suggest that these types of samplers have the potential to provide a representative sample of both VOCs and ionic solutes from ground water (Kaplan and others, 1991; Theodore A. Ehlke, U.S. Geological Survey, written commun., 2001). The purpose of this report is to provide results of field tests investigating the potential to use diffusion samplers to collect representative samples of inorganic constituents from ground water in wells and at an arsenic-contaminated ground-water-discharge zone beneath a stream. The investigations were performed at NIROP, Fridley, Minn. (fig. 1) and at NAS Fort Worth JRB, Texas (fig. 2). Two types of samplers were tested. One type was a nylon-screen sampler, which consisted of a 30-mL jar filled with deionized water, with its opening covered by a nylon screen. The second type was a dialysis sampler that consisted of a tube of dialysis membrane filled with deionized water. The nylon-screen samplers were deployed in wells at NIROP Fridley and NAS Fort Worth JRB and beneath the ground-water/surface water interface of a stream at NAS Fort Worth JRB. The dialysis samplers were deployed only in wells at NAS Fort Worth JRB.
Witschger, O; Grinshpun, S A; Fauvel, S; Basso, G
2004-06-01
While personal aerosol samplers have been characterized primarily based on wind tunnel tests conducted at relatively high wind speeds, modern indoor occupational environments are usually represented by very slow moving air. Recent surveys suggest that elevated levels of occupational exposure to inhalable airborne particles are typically observed when the worker, operating in the vicinity of the dust source, faces the source. Thus, the first objective of this study was to design and test a new, low cost experimental protocol for measuring the sampling efficiency of personal inhalable aerosol samplers in the vicinity of the aerosol source when the samplers operate in very slowly moving air. In this system, an aerosol generator, which is located in the centre of a room-sized non-ventilated chamber, continuously rotates and omnidirectionally disperses test particles of a specific size. The test and reference samplers are equally distributed around the source at the same distance from the centre and operate in parallel (in most of our experiments, the total number of simultaneously operating samplers was 15). Radial aerosol transport is driven by turbulent diffusion and some natural convection. For each specific particle size and the sampler, the aerosol mass concentration is measured by weighing the collection filter. The second objective was to utilize the new protocol to evaluate three widely used aerosol samplers: the IOM Personal Inhalable Sampler, the Button Personal Inhalable Aerosol Sampler and the 25 mm Millipore filter holder (closed-face C25 cassette). The sampling efficiencies of each instrument were measured with six particle fractions, ranging from 6.9 to 76.9 micro m in their mass median aerodynamic diameter. The Button Sampler efficiency data demonstrated a good agreement with the standard inhalable convention and especially with the low air movement inhalabilty curve. The 25 mm filter holder was found to considerably under-sample the particles larger than 10 micro m; its efficiency did not exceed 7% for particles of 40-100 micro m. The IOM Sampler facing the source was found to over-sample compared with the data obtained previously with a slowly rotating, freely suspended sampler in a low air movement environment. It was also found that the particle wall deposition in the IOM metallic cartridge was rather significant and particle size-dependent. For each sampler (IOM, Button and C25) the precision was characterized through the relative standard deviation (RSD) of the aerosol concentration obtained with identical samplers in a specific experiment. The average RSD was 14% for the IOM Sampler, 11% for the Button Sampler and 35% for the 25 mm filter cassette. A separate set of experiments, performed with the Simplified Torso showed that in very slowly moving air a personal sampler can be adequately evaluated even when it is not attached to a body but freely suspended (confirming the data reported previously).
NASA Astrophysics Data System (ADS)
Sabol, T. A.; Topping, D. J.; Griffiths, R. E.
2011-12-01
Accurate measurements of suspended-sediment concentration require suspended-sediment samplers to operate isokinetically with an intake-efficiency of 1.0 ± 0.10. Results from 1940s Federal Interagency Sedimentation Project (FISP) laboratory experiments show that when the intake efficiency does not equal 1.0, suspended-sediment samplers either under- or oversample sediment relative to water, leading to biases in suspended-sediment concentration. The majority of recent FISP sampler development and testing has been conducted under uniform flow conditions using flume and slack-water tow tests, with little testing in actual turbulent rivers. Recent work has focused on the hydraulic characteristics and intake efficiencies of these samplers, without field investigations of the accuracy of the suspended-sediment data collected with these samplers. When depth-integrating suspended-sediment samplers are deployed under the non-uniform and turbulent conditions that exist in rivers, multiple factors may contribute to departures from isokinetic sampling. This introduces errors into the suspended-sediment data that may not be predictable on the basis of flume and tow tests alone. This study (1) evaluates the intake efficiencies of the older US D-77 bag-type and newer, FISP-approved US D-96 samplers at multiple river cross sections under a range of flow conditions; (2) examines if water temperature and sampling duration explain measured differences in intake efficiency between samplers and between laboratory and field tests; (3) models and predicts the directions and magnitudes of errors in measured suspended-sand concentration; and (4) determines if the relative differences in suspended-sediment concentration in a variety of size classes are consistent with the differences expected on the basis of the 1940s FISP-laboratory experiments. Results indicate that under river conditions, the intake efficiency of the US D-96 sampler is superior to that of the US D-77 bag-type sampler and the overall performance of the US D-96 sampler is closer to the FISP-acceptable range of isokinetic operation. These results are in contrast with FISP-conducted flume tests that show that both the US D-77 bag-type and US D-96 samplers operate isokinetically in the laboratory. Our results show that a major problem with both samplers is the large time-dependent decrease in intake efficiency that likely arises from an inability of the filling bag to displace water in the flooded sampler cavity at the rate required for isokinetic sampling. Predicted errors in suspended-sand concentration measurements made with the US D-96 sampler are much smaller than those made with the US D-77 bag-type sampler, especially when the effects of water temperature and sampling duration are taken into account. Biases in the concentrations in each size class measured using the US D-77 bag-type relative to the US D-96 samplers are as expected and consistent with the results from the 1940s FISP laboratory experiments.
A Homemade Instrument for Collecting Soil Water From Porous Ceramic Cups
M. Dean Knighton; Dwight E. Streblow
1981-01-01
An efficient Ceramic-Cup Water Collection Instrument (CCWCI, "quickie") is described. Soil water collection from ceramic-cup samplers may require compositing by equal volume from distantly spaced samplers, or simultaneous water collection spaced samplers, or simultaneous water collection from closely spaced samplers without compositing. All collection must...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 19 2013-07-01 2013-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 19 2012-07-01 2012-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 19 2014-07-01 2014-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
40 CFR 86.519-90 - Constant volume sampler calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Constant volume sampler calibration... Regulations for 1978 and Later New Motorcycles; Test Procedures § 86.519-90 Constant volume sampler calibration. (a) The CVS (Constant Volume Sampler) is calibrated using an accurate flowmeter and restrictor...
Sabol, Thomas A.; Topping, David J.
2013-01-01
Accurate measurements of suspended-sediment concentration require suspended-sediment samplers to operate isokinetically, within an intake-efficiency range of 1.0 ± 0.10, where intake efficiency is defined as the ratio of the velocity of the water through the sampler intake to the local ambient stream velocity. Local ambient stream velocity is defined as the velocity of the water in the river at the location of the nozzle, unaffected by the presence of the sampler. Results from Federal Interagency Sedimentation Project (FISP) laboratory experiments published in the early 1940s show that when the intake efficiency is less than 1.0, suspended-sediment samplers tend to oversample sediment relative to water, leading to potentially large positive biases in suspended-sediment concentration that are positively correlated with grain size. Conversely, these experiments show that, when the intake efficiency is greater than 1.0, suspended‑sediment samplers tend to undersample sediment relative to water, leading to smaller negative biases in suspended-sediment concentration that become slightly more negative as grain size increases. The majority of FISP sampler development and testing since the early 1990s has been conducted under highly uniform flow conditions via flume and slack-water tow tests, with relatively little work conducted under the greater levels of turbulence that exist in actual rivers. Additionally, all of this recent work has been focused on the hydraulic characteristics and intake efficiencies of these samplers, with no field investigations conducted on the accuracy of the suspended-sediment data collected with these samplers. When depth-integrating suspended-sediment samplers are deployed under the more nonuniform and turbulent conditions that exist in rivers, multiple factors may contribute to departures from isokinetic sampling, thus introducing errors into the suspended-sediment data collected by these samplers that may not be predictable on the basis of flume and tow tests alone. This study has three interrelated goals. First, the intake efficiencies of the older US D-77 bag-type and newer, FISP-approved US D-96-type1 depth-integrating suspended‑sediment samplers are evaluated at multiple cross‑sections under a range of actual-river conditions. The intake efficiencies measured in these actual-river tests are then compared to those previously measured in flume and tow tests. Second, other physical effects, mainly water temperature and the duration of sampling at a vertical, are examined to determine whether these effects can help explain observed differences in intake efficiency both between the two types of samplers and between the laboratory and field tests. Third, the signs and magnitudes of the likely errors in suspendedsand concentration in measurements made with both types of samplers are predicted based the intake efficiencies of these two types of depth-integrating samplers. Using the relative difference in isokinetic sampling observed between the US D-77 bag-type and D-96-type samplers during river tests, measured differences in suspended-sediment concentration in a variety of size classes were evaluated between paired equal-discharge-increment (EDI) and equal-width-increment (EWI) measurements made with these two types of samplers to determine whether these differences in concentration are consistent with the differences in concentrations expected on the basis of the 1940s FISP laboratory experiments. In addition, sequential single-vertical depth-integrated samples were collected (concurrent with velocity measurements) with the US D-96-type bag sampler and two different rigidcontainer samplers to evaluate whether the predicted errors in suspended-sand concentrations measured with the US D-96- type sampler are consistent with those expected on the basis of the 1940s FISP laboratory experiments. Results from our study indicate that the intake efficiency of the US D-96-type sampler is superior to that of the US D-77 bag-type sampler under actual-river conditions, with overall performance of the US D-96-type sampler being closer to, yet still typically below, the FISP-acceptable range of isokinetic operation. These results are in contrast to the results from FISP-conducted flume tests that showed that both the US D-77 bag-type and US D-96-type samplers sampled isokinetically in the laboratory. Results from our study indicate that the single largest problem with the behavior of both the US D-77 bag-type and the US D-96-type samplers under actual‑river conditions is that both samplers are prone to large time‑dependent decreases in intake efficiency as sampling duration increases. In the case of the US D-96-type sampler, this problem may be at least partially overcome by shortening the duration of sampling (or, instead, perhaps by a simple design improvement); in the case of the US D-77 bag-type sampler, although shortening the sampling duration improves the intake efficiency, it does not bring it into agreement with the FISP‑accepted range of isokinetic operation. The predicted errors in suspended-sand concentration in EDI or EWI measurements made with the US-96-type sampler are much smaller than those associated with EDI or EWI measurements made with the US D-77 bag-type sampler, especially when the results are corrected for the effects of water temperature and sampling duration. The bias in the concentration in each size class measured using the US D-77 bag-type relative to the concentration measured using the US D-96-type sampler behaves in a manner consistent with that expected on the basis of the observed differences in intake efficiency between the two samplers in conjunction with the results from the 1940s FISP laboratory experiments. In addition, the bias in the concentration in each size class measured using the US D-96‑type sampler relative to the concentration measured using the truly isokinetic rigid-container samplers is in excellent agreement with that predicted on the basis of the 1940s FISP laboratory experiments. Because suspended-sediment samplers can respond differently between laboratory and field conditions, actual-river tests such as those in this study should be conducted when models of suspended-sediment samplers are changed from one type to another during the course of long-term monitoring programs. Otherwise, potential large differences in the suspended-sediment data collected by different types of samplers would lead to large step changes in sediment loads that may be misinterpreted as real, when, in fact, they are associated with the change in suspended‑sediment sampling equipment.
Pan, Yuxiang; Wang, Cong; Chen, Zhongqin; Li, Weiwei; Yuan, Guoqi; Chen, Haixia
2017-05-15
This study aimed to investigate the physicochemical properties and antidiabetic effects of a polysaccharide obtained from corn silk (PCS2). PCS2 was isolated and the physicochemical properties were characterized. The hypoglycemic effects were determined using the high-fat diet and streptozocin induced type 2 diabetic mellitus (T2DM) insulin resistance mice. The results showed that PCS2 was a heteropolysaccharide with the average molecular weight of 45.5kDa. PCS2 was composed of d-galactose, d-mannose, d-(+)-glucose, d-(+)-xylose, l-arabinose and l-rhamnose. PCS2 treatment significantly reduced the body weight loss, decreased blood glucose and serum insulin levels, and improved glucose intolerance (P<0.05). The levels of serum lipid profile were regulated and the levels of glycated serum protein, non-esterified fatty acid were decreased significantly (P<0.01). The activities of superoxide dismutase, glutathione peroxidase and catalase were notably improved (P<0.05). PCS2 also exerted cytoprotective action from histopathological observation. These results suggested that PCS2 could be a good candidate of functional food or medicine for T2DM treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.
Retrospectively evaluated preinjury personality traits influence postconcussion symptoms.
Yuen, Kit-Man; Tsai, Yi-Hsin; Lin, Wei-Chi; Yang, Chi-Cheng; Huang, Sheng-Jean
2016-01-01
Postconcussion symptoms (PCS) are not uncommon following mild traumatic brain injury (mTBI). Personality traits have always been viewed as one of the most important explanations for persistent postconcussion symptoms (PPCS). Unfortunately, studies on the association between preinjury personality traits and the PPCS are still limited. This study thus aimed to examine the relationship between the preinjury personality and PCS in patients with mTBI. A total of 106 participants including 53 healthy participants were recruited. All participants complete the modified Checklist of Postconcussion Symptoms and the Health, Personality, & Habit Scale. Participants were evaluated within 4 weeks and at 4 months, respectively, after injury. The results showed patients reported significantly more PCS than healthy participants did within 4 weeks postinjury. A significant positive association between PCS and retrospectively evaluated preinjury personality was found. Specifically, patients who reported that their preinjury personality was depressive or anxious-related presented more PCS. This study might be the first to directly demonstrate that preinjury personality traits are closely linked to PCS reporting in patients with mTBI. Importantly, PCS reporting might be associated with different personality traits at different periods after injuries, and thus, a careful evaluation for personality characteristics is merited after mTBI.
Gryp, Tessa; Vanholder, Raymond; Vaneechoutte, Mario; Glorieux, Griet
2017-01-01
If chronic kidney disease (CKD) is associated with an impairment of kidney function, several uremic solutes are retained. Some of these exert toxic effects, which are called uremic toxins. p-Cresyl sulfate (pCS) is a prototype protein-bound uremic toxin to which many biological and biochemical (toxic) effects have been attributed. In addition, increased levels of pCS have been associated with worsening outcomes in CKD patients. pCS finds its origin in the intestine where gut bacteria metabolize aromatic amino acids, such as tyrosine and phenylalanine, leading to phenolic end products, of which pCS is one of the components. In this review we summarize the biological effects of pCS and its metabolic origin in the intestine. It appears that, according to in vitro studies, the intestinal bacteria generating phenolic compounds mainly belong to the families Bacteroidaceae, Bifidobacteriaceae, Clostridiaceae, Enterobacteriaceae, Enterococcaceae, Eubacteriaceae, Fusobacteriaceae, Lachnospiraceae, Lactobacillaceae, Porphyromonadaceae, Staphylococcaceae, Ruminococcaceae, and Veillonellaceae. Since pCS remains difficult to remove by dialysis, the gut microbiota could be a future target to decrease pCS levels and its toxicity, even at earlier stages of CKD, aiming at slowing down the progression of the disease and decreasing the cardiovascular burden. PMID:28146081
Remediation of Petroleum-Contaminated Soil and Simultaneous Recovery of Oil by Fast Pyrolysis.
Li, De-Chang; Xu, Wan-Fei; Mu, Yang; Yu, Han-Qing; Jiang, Hong; Crittenden, John C
2018-05-01
Petroleum-contaminated soil (PCS) caused by the accidental release of crude oil into the environment, which occurs frequently during oil exploitation worldwide, needs efficient and cost-effective remediation. In this study, a fast pyrolysis technology was implemented to remediate the PCS and concurrently recover the oil. The remediation effect related to pyrolytic parameters, the recovery rate of oil and its possible formation pathway, and the physicochemical properties of the remediated PCS and its suitability for planting were systematically investigated. The results show that 50.9% carbon was recovered in oil, whose quality even exceeds that of crude oil. Both extractable total petroleum hydrocarbon (TPH) and water-soluble organic matter (SOM) in PCS were completely removed at 500 °C within 30 min. The remaining carbon in remediated PCS was determined to be in a stable and innocuous state, which has no adverse effect on wheat growth. On the basis of the systematically characterizations of initial PCS and pyrolytic products, a possible thermochemical mechanism was proposed which involves evaporation, cracking and polymerization. In addition, the energy consumption analysis and remediation effect of various PCSs indicate that fast pyrolysis is a viable and cost-effective method for PCS remediation.
Caldwell, Andral W.; Falls, W. Fred; Guimaraes, Wladmir B.; Ratliff, W. Hagan; Wellborn, John B.; Landmeyer, James E.
2012-01-01
Soil gas was assessed for contaminants at three former fuel-dispensing sites at Fort Gordon, Georgia, from October 2010 to September 2011. The assessment included delineation of organic contaminants using soil-gas samplers collected from the former fuel-dispensing sites at 8th Street, Chamberlain Avenue, and 12th Street. This assessment was conducted to provide environmental contamination data to Fort Gordon personnel pursuant to requirements for the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. Soil-gas samplers installed and retrieved during June and August 2011 at the 8th Street site had detections above the method detection level (MDL) for the mass of total petroleum hydrocarbons (TPH), benzene, toluene, ortho-xylene, undecane, tridecane, pentadecane, and chloroform. Total petroleum hydrocarbons soil-gas mass exceeded the MDL of 0.02 microgram in 54 of the 55 soil-gas samplers. The highest detection of TPH soil-gas mass was 146.10 micrograms, located in the central part of the site. Benzene mass exceeded the MDL of 0.01 microgram in 23 soil-gas samplers, whereas toluene was detected in only 10 soil-gas samplers. Ortho-xylene was detected above the MDL in only one soil-gas sampler. The highest soil-gas mass detected for undecane, tridecane, and pentadecane was located in the northeastern corner of the 8th Street site. Chloroform mass greater than the MDL of 0.01 microgram was detected in less than one-third of the soil-gas samplers. Soil-gas masses above the MDL were identified for TPH, gasoline-related compounds, diesel-range alkanes, trimethylbenzenes, naphthalene, 2-methyl-napthalene, octane, and tetrachloroethylene for the July 2011 soil-gas survey at the Chamberlain Avenue site. All 30 of the soil-gas samplers contained TPH mass above the MDL. The highest detection of TPH mass, 426.36 micrograms, was for a soil-gas sampler located near the northern boundary of the site. Gasoline-related compounds and diesel-range alkanes were detected in multiple soil-gas samplers, and the highest detections of these compounds were located near the central part of the site near existing, nonoperational, fuel-dispensing pumps. Trimethylbenzenes were detected in less than half of the soil-gas samplers. Naphthalene soil-gas mass was detected above the MDL in 10 soil-gas samplers, whereas 2-methyl-napthalene was detected above the MDL in half of the soil-gas samplers. Octane mass was detected above the MDL in one soil-gas sampler located near the central part of the site. Tetrachloroethylene soil-gas mass was detected above the MDL in more than half of the soil-gas samplers, and the highest tetrachloroethylene soil-gas mass of 0.90 microgram was located in the northeastern part of the site. Soil-gas samplers collected at the 12th Street site during July 2011 contained soil-gas mass above the MDL for TPH, toluene, undecane, tridecane, and pentadecane (diesel-range alkanes), trichloroethylene, 1,4-dichlorobenzene, chloroform, and 1,2,4-trimethylbenzene. The highest detected TPH mass was 24.37 micrograms in a soil-gas sampler located in the northern part of the site. The highest detection of toluene soil-gas mass was from a soil-gas sampler located near the southern boundary of the site. The diesel-range alkanes were detected above the MDL in five soil-gas samplers; the highest detection of soil-gas diesel mass, 0.65 microgram, was located in the southern part of the site. Trichloroethylene and 1,4-dichlorobenzene were detected above the MDL in the northern part of the site in one soil-gas sampler that also had one of the highest detections of TPH. Chloroform was detected above the MDL in three soil-gas samplers, whereas 1,2,4-trimethylbenzene soil-gas mass was detected above the MDL in two soil-gas samplers.
Photophysical properties gallium octacarboxy phthalocyanines conjugated to CdSe@ZnS quantum dots.
Tshangana, Charmaine; Nyokong, Tebello
2015-01-01
L-Glutathione (GSH) capped core CdSe (2.3 nm) and core shell CdSe@ZnS quantum dots (QDs) (3.0 nm and 3.5 nm) were coordinated to gallium octacarboxy phthalocyanine (ClGaPc(COOH)8) to form ClGaPc(COOH)8-QDs conjugates. An efficient transfer of energy from the QDs to the Pcs was demonstrated through Förster resonance energy transfer (FRET), the FRET efficiencies in all cases was above 50%. The photophysical parameters (triplet state and fluorescence quantum yields and lifetimes) were also determined for the conjugates. There was a decrease in the fluorescence lifetimes of ClGaPc(COOH)8 in the presence of all the QDs, due to the heavy atom effect. The triplet quantum yields increased in the conjugates. The lifetimes also became longer for the conjugates compared to Pc alone. Copyright © 2015 Elsevier B.V. All rights reserved.
47 CFR 24.239 - Cost-sharing requirements for broadband PCS.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES PERSONAL COMMUNICATIONS SERVICES Broadband PCS Policies Governing Microwave Relocation from the...) are required to relocate the existing Fixed Microwave Services (FMS) licensees in these bands if... by other PCS entities or a voluntarily relocating microwave incumbent, must contribute to such...
47 CFR 24.239 - Cost-sharing requirements for broadband PCS.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES PERSONAL COMMUNICATIONS SERVICES Broadband PCS Policies Governing Microwave Relocation from the...) are required to relocate the existing Fixed Microwave Services (FMS) licensees in these bands if... by other PCS entities or a voluntarily relocating microwave incumbent, must contribute to such...
47 CFR 24.239 - Cost-sharing requirements for broadband PCS.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES PERSONAL COMMUNICATIONS SERVICES Broadband PCS Policies Governing Microwave Relocation from the...) are required to relocate the existing Fixed Microwave Services (FMS) licensees in these bands if... by other PCS entities or a voluntarily relocating microwave incumbent, must contribute to such...
47 CFR 24.239 - Cost-sharing requirements for broadband PCS.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES PERSONAL COMMUNICATIONS SERVICES Broadband PCS Policies Governing Microwave Relocation from the...) are required to relocate the existing Fixed Microwave Services (FMS) licensees in these bands if... by other PCS entities or a voluntarily relocating microwave incumbent, must contribute to such...
Pfeifle, Bryce D.; Stamm, John F.; Stone, James J.
2018-01-01
Gold mining operations in the northern Black Hills of South Dakota resulted in the discharge of arsenopyrite-bearing mine tailings into Whitewood Creek from 1876 to 1977. Those tailings were transported further downstream along the Belle Fourche River, the Cheyenne River, and the Missouri River. An estimated 110 million metric tons of tailings remain stored in alluvial deposits of the Belle Fourche and Cheyenne Rivers. Pore-water dialysis samplers were deployed in the channel and backwaters of the Belle Fourche and Cheyenne Rivers to determine temporal and seasonal changes in the geochemistry of groundwater in alluvial sediments. Alluvial sediment adjacent to the dialysis samplers were cored for geochemical analysis. In comparison to US Environmental Protection Agency drinking water standards and reference concentrations of alluvial sediment not containing mine tailings, the Belle Fourche River sites had elevated concentrations of arsenic in pore water (2570 μg/L compared to 10 μg/L) and sediment (1010 ppm compared to < 34 ppm), respectively. Pore water arsenic concentration was affected by dissolution of iron oxyhydroxides under reducing conditions. Sequential extraction of iron and arsenic from sediment cores indicates that substantial quantities of soluble metals were present. Dissolution of arsenic sorbed to alluvial sediment particles appears to be affected by changing groundwater levels that cause shifts in redox conditions. Bioreductive processes did not appear to be a substantial transport pathway but could affect speciation of arsenic, especially at the Cheyenne River sampling sites where microbial activity was determined to be greater than at Belle Fourche sampling sites.
NASA Astrophysics Data System (ADS)
Bocsi, József; Pierzchalski, Arkadiusz; Marecka, Monika; Malkusch, Wolf; Tárnok, Attila
2009-02-01
Slide-based cytometry (SBC) leads to breakthrough in cytometry of cells in tissues, culture and suspension. Carl Zeiss Imaging Solutions' new automated SFM combines imaging with cytometry. A critical step in image analysis is selection of appropriate triggering signal to detect all objects. Without correct target cell definition analysis is hampered. DNA-staining is among the most common triggering signals. However, the majority of DNA-dyes yield massive spillover into other fluorescence channels limiting their application. By microscopy objects of >5μm diameter can be easily detected by phase-contrast signal (PCS) without any staining. Aim was to establish PCS - triggering for cell identification. Axio Imager.Z1 motorized SFM was used (high-resolution digital camera, AxioCam MRm; AxioVision software: automatic multi-channel scanning, analysis). Leukocytes were stained with FITC (CD4, CD8) and APC (CD3) labelled antibodies in combinations using whole blood method. Samples were scanned in three channels (PCS/FITC/APC). Exposition-times for PCS were set as low as possible; the detection efficiency was verified by fluorescence. CD45-stained leukocytes were counted and compared to the number of PCS detected events. Leukocyte subtyping was compared with other cytometers. In focus the PCS of cells showed ring-form that was not optimal for cell definition. Out of focus PCS allows more effective qualitative and quantitative cell analyses. PCS was an accurate triggering signal for leukocytes enabling cell counting and discrimination of leukocytes from platelets. Leukocyte subpopulation frequencies were comparable to those obtained by other cytometers. In conclusion PCS is a suitable trigger-signal not interfering with fluorescence detection.
Hundhausen, T; Müller, T H
2005-08-01
The microbial detection system BacT/ALERT (bioMérieux) is widely used to monitor bacterial contamination of platelet concentrates (PCs). Recently, the manufacturer introduced polycarbonate culture bottles and a modified pH-sensitive liquid emulsion sensor as microbial growth indicator. This reconfigured assay was investigated in a routine setting. In each of eight transfusion centers, samples from 500 consecutive PCs were monitored for 1 week. For all PCs with a positive BacT/ALERT signal, retained samples and, if available, original PC containers and concomitant red blood cell concentrates were analyzed independently. Initially BacT/ALERT-positive PCs without bacterial identification in any sample were defined as false-positive. BacT/ALERT-positive PCs with bacteria in the first sample only were called potentially positive. PCs with bacteria in the first sample and the same strain in at least one additional sample were accepted as positive. Five PCs (0.13%) were positive, 9 PCs (0.23%) were potentially positive, and 35 PCs (0.9%) were false-positive. The rate of false-positive BacT/ALERT results varied substantially between centers (<0.2%-3.2%). Tracings from false-positive cultures lacked an exponential increase of the signal during incubation. Most of these false-positives were due to malfunctioning cells in various BacT/ALERT incubation units. Careful assessment of individual tracings of samples with positive signals helps to identify malfunctioning incubation units. Their early shutdown or replacement minimizes the high rate of unrectifiable product rejects attributed to false-positive alarms and avoids unnecessary concern of doctors and patients after conversion to a reconfigured BacT/ALERT assay.
Beshkar, Pezhman; Hosseini, Ehteramolsadat; Ghasemzadeh, Mehran
2018-02-01
Regardless of different sources, methods or devices which are applied for preparation of therapeutic platelets, these products are generally isolated from whole blood by the sedimentation techniques which are based on PRP or buffy coat (BC) separation. As a general fact, platelet preparation and storage are also associated with some deleterious changes that known as platelet storage lesion (PSL). Although these alternations in platelet functional activity are aggravated during storage, whether technical issues within preparation can affect integrin activation and platelet adhesion to fibrinogen were investigated in this study. PRP- and BC-platelet concentrates (PCs) were subjected to flowcytometry analysis to examine the expression of platelet activation marker, P-selectin as well as active confirmation of the GPIIb/IIIa (α IIb β 3 ) on day 0, 1, 3 and 5 post-storage. Platelet adhesion to fibrinogen matrix was evaluated by fluorescence microscopy. Glucose concentration and LDH activity were also measured by colorimetric methods. The increasing P-selectin expression during storage was in a reverse correlation with PAC-1 binding (r = -0.67; p = .001). PRP-PCs showed the higher level of P-selectin expression than BC-PCs, whereas the levels of PAC-1 binding and platelet adhesion to fibrinogen matrix were significantly lower in PRP-PCs. Higher levels of active confirmation of the GPIIb/IIIa in BC-PCs were also associated with greater concentration of glucose in these products. We demonstrated the superior capacities of integrin activation and adhesion to fibrinogen for BC-PCs compared to those of PRP-PCs. These findings may provide more advantages for BC method of platelet preparation. Copyright © 2017 Elsevier Ltd. All rights reserved.
The ionic bases of the action potential in isolated mouse cardiac Purkinje cell.
Vaidyanathan, Ravi; O'Connell, Ryan P; Deo, Makarand; Milstein, Michelle L; Furspan, Philip; Herron, Todd J; Pandit, Sandeep V; Musa, Hassan; Berenfeld, Omer; Jalife, José; Anumonwo, Justus M B
2013-01-01
Collecting electrophysiological and molecular data from the murine conduction system presents technical challenges. Thus, only little advantage has been taken of numerous genetically engineered murine models to study excitation through the cardiac conduction system of the mouse. To develop an approach for isolating murine cardiac Purkinje cells (PCs), to characterize major ionic currents and to use the data to simulate action potentials (APs) recorded from PCs. Light microscopy was used to isolate and identify PCs from apical and septal cells. Current and voltage clamp techniques were used to record APs and whole cell currents. We then simulated a PC AP on the basis of our experimental data. APs recorded from PCs were significantly longer than those recorded from ventricular cells. The prominent plateau phase of the PC AP was very negative (≈-40 mV). Spontaneous activity was observed only in PCs. The inward rectifier current demonstrated no significant differences compared to ventricular myocytes (VMs). However, sodium current density was larger, and the voltage-gated potassium current density was significantly less in PCs compared with myocytes. T-type Ca(2+) currents (I(Ca,T)) were present in PCs but not VMs. Computer simulations suggest that I(Ca,T) and cytosolic calcium diffusion significantly modulate AP profile recorded in PCs, as compared to VMs. Our study provides the first comprehensive ionic profile of murine PCs. The data show unique features of PC ionic mechanisms that govern its excitation process. Experimental data and numerical modeling results suggest that a smaller voltage-gated potassium current and the presence of I(Ca,T) are important determinants of the longer and relatively negative plateau phase of the APs. Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orwig, Susan D.; Tan, Yun Lei; Grimster, Neil P.
2013-03-07
Pharmacologic chaperoning is a therapeutic strategy being developed to improve the cellular folding and trafficking defects associated with Gaucher disease, a lysosomal storage disorder caused by point mutations in the gene encoding acid-{beta}-glucosidase (GCase). In this approach, small molecules bind to and stabilize mutant folded or nearly folded GCase in the endoplasmic reticulum (ER), increasing the concentration of folded, functional GCase trafficked to the lysosome where the mutant enzyme can hydrolyze the accumulated substrate. To date, the pharmacologic chaperone (PC) candidates that have been investigated largely have been active site-directed inhibitors of GCase, usually containing five- or six-membered rings, suchmore » as modified azasugars. Here we show that a seven-membered, nitrogen-containing heterocycle (3,4,5,6-tetrahydroxyazepane) scaffold is also promising for generating PCs for GCase. Crystal structures reveal that the core azepane stabilizes GCase in a variation of its proposed active conformation, whereas binding of an analogue with an N-linked hydroxyethyl tail stabilizes GCase in a conformation in which the active site is covered, also utilizing a loop conformation not seen previously. Although both compounds preferentially stabilize GCase to thermal denaturation at pH 7.4, reflective of the pH in the ER, only the core azepane, which is a mid-micromolar competitive inhibitor, elicits a modest increase in enzyme activity for the neuronopathic G202R and the non-neuronopathic N370S mutant GCase in an intact cell assay. Our results emphasize the importance of the conformational variability of the GCase active site in the design of competitive inhibitors as PCs for Gaucher disease.« less
21 CFR 884.1560 - Fetal blood sampler.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...
21 CFR 884.1560 - Fetal blood sampler.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...
21 CFR 884.1560 - Fetal blood sampler.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...
21 CFR 884.1560 - Fetal blood sampler.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...
21 CFR 884.1560 - Fetal blood sampler.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fetal blood sampler. 884.1560 Section 884.1560... § 884.1560 Fetal blood sampler. (a) Identification. A fetal blood sampler is a device used to obtain fetal blood transcervically through an endoscope by puncturing the fetal skin with a short blade and...
Student Sampler: Facts in Brief on North Carolina.
ERIC Educational Resources Information Center
North Carolina State Dept. of Public Instruction, Raleigh.
This information sampler was compiled to assist students in their study of North Carolina. Every year North Carolina students must complete a special project on their state. The sampler was designed to introduce students to the people, places, and events that have shaped North Carolina's history. Topics in the sampler include state symbols,…
NASA Astrophysics Data System (ADS)
Lin, Chaojing; Morita, Kyosuke; Muraki, Koji; Fujisawa, Toshimasa
2018-04-01
Edge magnetoplasmons (EMPs) are unidirectional charge density waves travelling in an edge channel of a two-dimensional electron gas in the quantum Hall regime. We present both generation and detection schemes with a photoconductive switch (PCS) for EMPs. Here, the conductance of the PCS is modulated by irradiation with a laser beam, whose amplitude can be modulated by an external signal. When the PCS is used as a generator, the electrical current from the PCS is injected into the edge channel to excite EMPs. When the PCS is used as a detector, the electronic potential induced by EMPs is applied to the PCS with a modulated laser beam so as to constitute a phase-sensitive measurement. For both experiments, we confirm that the time of flight for the EMPs increases with the magnetic field in agreement with the EMP characteristics. Combination of the two schemes would be useful in investigating and utilizing EMPs at higher frequencies.
Imprinting the Fate of Antigen-Reactive B Cells through the Affinity of the B Cell Receptor
O'Connor, Brian P.; Vogel, Laura A.; Zhang, Weijun; Loo, William; Shnider, Danielle; Lind, Evan F.; Ratliff, Michelle; Noelle, Randolph J.; Erickson, Loren D.
2010-01-01
Long-lived plasma cells (PCs) and memory B cells (Bmem) constitute the cellular components of enduring humoral immunity, whereas short-lived PCs that rapidly produce Ig correspond to the host's need for immediate protection against pathogens. In this study we show that the innate affinity of the BCR for Ag imprints upon naive B cells their differentiation fate to become short-or long-lived PCs and Bmem. Using BCR transgenic mice with varying affinities for Ag, naive B cells with high affinity lose their capacity to form germinal centers (GCs), develop neither Bmem nor long-lived PCs, and are destined to a short-lived PC fate. Moderate affinity interactions result in hastened GC responses, and differentiation to long-lived PCs, but Bmem remain extinct. In contrast, lower affinity interactions show tempered GCs, producing Bmem and affinity-matured, long-lived PCs. Thus, a continuum of elementary to comprehensive humoral immune responses exists that is controlled by inherent BCR affinity. PMID:17114443
Kundu, Chanchal Kumar; Wang, Xin; Hou, Yanbei; Hu, Yuan
2018-02-01
Phosphorylated chitosan (PCS) was synthesized and grafted onto the surface of polyamide 6.6 (PA 6.6) fabrics via UV-induced grafting polymerization in order to improve the flame retardant properties. Subsequently, PCS grafted PA 6.6 fabrics were modified by (3-aminopropyl) triethoxysilane (APTES) through sol-gel process in order to form a cross-linking coating. The results obtained from the vertical burning test indicated that only the PCS grafted and simultaneously sol-gel treated fabrics could stop the melt dripping. A maximum reduction (30%) in the peak heat release rate was achieved for the PA6.6-PCS-4W-SG fabric sample. The optimal flame retardant effect was achieved for the PA6.6 fabrics treated by PCS and APTES simultaneously, which was attributed to the joint effect of thermal shielding exerted by the silica and char-forming effect derived from PCS. Copyright © 2017 Elsevier Ltd. All rights reserved.
Subbian, Vignesh; Meunier, Jason M; Korfhagen, Joseph J; Ratcliff, Jonathan J; Shaw, George J; Beyette, Fred R
2014-01-01
Post-Concussion Syndrome (PCS) is a common sequelae of mild Traumatic Brain Injury (mTBI). Currently, there is no reliable test to determine which patients will develop PCS following an mTBI. As a result, clinicians are challenged to identify patients at high risk for subsequent PCS. Hence, there is a need to develop an objective test that can guide clinical risk stratification and predict the likelihood of PCS at the initial point of care in an Emergency Department (ED). This paper presents the results of robotic-assisted neurologic testing completed on mTBI patients in the ED and its ability to predict PCS at 3 weeks post-injury. Preliminary results show that abnormal proprioception, as measured using robotic testing is associated with higher risk of developing PCS following mTBI. In this pilot study, proprioceptive measures obtained through robotic testing had a 77% specificity (95CI: 46%-94%) and a 64% sensitivity (95CI: 41%-82%).
Formaldehyde levels in traditional and portable classrooms: A pilot investigation
2015-01-01
This pilot study assessed formaldehyde levels in portable classrooms (PCs) and traditional classrooms (TCs) and explored factors influencing indoor air quality (e.g., carbon dioxide (CO2), temperature, and relative humidity). In a cross-sectional design, we evaluated formaldehyde levels in day and overnight indoor air samples from nine PCs renovated within three years previously and three TCs in a school district in metropolitan Atlanta, Georgia. Formaldehyde levels ranged from 0.0068 to 0.038 ppm. In both type of classrooms, overnight formaldehyde median levels (PCs = 0.018 ppm; TCs = 0.019 ppm) were higher than day formaldehyde median levels (PCs = 0.011 ppm; TCs = 0.016 ppm). CO2 levels measured 470–790 parts per million (ppm) at 7AM and 470–1800 ppm at 4PM. Afternoon medians were higher in TCs (1,400 ppm ) than in PCs (780 ppm). Consistent with previous studies, formaldehyde levels were similar among PCs and TCs. Reducing CO2 levels by improving ventilation is recommended for classrooms. PMID:27197349
Waste receiving and processing plant control system; system design description
DOE Office of Scientific and Technical Information (OSTI.GOV)
LANE, M.P.
1999-02-24
The Plant Control System (PCS) is a heterogeneous computer system composed of numerous sub-systems. The PCS represents every major computer system that is used to support operation of the Waste Receiving and Processing (WRAP) facility. This document, the System Design Description (PCS SDD), includes several chapters and appendices. Each chapter is devoted to a separate PCS sub-system. Typically, each chapter includes an overview description of the system, a list of associated documents related to operation of that system, and a detailed description of relevant system features. Each appendice provides configuration information for selected PCS sub-systems. The appendices are designed asmore » separate sections to assist in maintaining this document due to frequent changes in system configurations. This document is intended to serve as the primary reference for configuration of PCS computer systems. The use of this document is further described in the WRAP System Configuration Management Plan, WMH-350, Section 4.1.« less
Event-related potentials for post-error and post-conflict slowing.
Chang, Andrew; Chen, Chien-Chung; Li, Hsin-Hung; Li, Chiang-Shan R
2014-01-01
In a reaction time task, people typically slow down following an error or conflict, each called post-error slowing (PES) and post-conflict slowing (PCS). Despite many studies of the cognitive mechanisms, the neural responses of PES and PCS continue to be debated. In this study, we combined high-density array EEG and a stop-signal task to examine event-related potentials of PES and PCS in sixteen young adult participants. The results showed that the amplitude of N2 is greater during PES but not PCS. In contrast, the peak latency of N2 is longer for PCS but not PES. Furthermore, error-positivity (Pe) but not error-related negativity (ERN) was greater in the stop error trials preceding PES than non-PES trials, suggesting that PES is related to participants' awareness of the error. Together, these findings extend earlier work of cognitive control by specifying the neural correlates of PES and PCS in the stop signal task.
Alpine cushion plants inhibit the loss of phylogenetic diversity in severe environments.
Butterfield, B J; Cavieres, L A; Callaway, R M; Cook, B J; Kikvidze, Z; Lortie, C J; Michalet, R; Pugnaire, F I; Schöb, C; Xiao, S; Zaitchek, B; Anthelme, F; Björk, R G; Dickinson, K; Gavilán, R; Kanka, R; Maalouf, J-P; Noroozi, J; Parajuli, R; Phoenix, G K; Reid, A; Ridenour, W; Rixen, C; Wipf, S; Zhao, L; Brooker, R W
2013-04-01
Biotic interactions can shape phylogenetic community structure (PCS). However, we do not know how the asymmetric effects of foundation species on communities extend to effects on PCS. We assessed PCS of alpine plant communities around the world, both within cushion plant foundation species and adjacent open ground, and compared the effects of foundation species and climate on alpha (within-microsite), beta (between open and cushion) and gamma (open and cushion combined) PCS. In the open, alpha PCS shifted from highly related to distantly related with increasing potential productivity. However, we found no relationship between gamma PCS and climate, due to divergence in phylogenetic composition between cushion and open sub-communities in severe environments, as demonstrated by increasing phylo-beta diversity. Thus, foundation species functioned as micro-refugia by facilitating less stress-tolerant lineages in severe environments, erasing a global productivity - phylogenetic diversity relationship that would go undetected without accounting for this important biotic interaction. © 2013 Blackwell Publishing Ltd/CNRS.
Evaluation of portable air samplers for monitoring airborne culturable bacteria
NASA Technical Reports Server (NTRS)
Mehta, S. K.; Bell-Robinson, D. M.; Groves, T. O.; Stetzenbach, L. D.; Pierson, D. L.
2000-01-01
Airborne culturable bacteria were monitored at five locations (three in an office/laboratory building and two in a private residence) in a series of experiments designed to compare the efficiency of four air samplers: the Andersen two-stage, Burkard portable, RCS Plus, and SAS Super 90 samplers. A total of 280 samples was collected. The four samplers were operated simultaneously, each sampling 100 L of air with collection on trypticase soy agar. The data were corrected by applying positive hole conversion factors for the Burkard portable, Andersen two-stage, and SAS Super 90 air samplers, and were expressed as log10 values prior to statistical analysis by analysis of variance. The Burkard portable air sampler retrieved the highest number of airborne culturable bacteria at four of the five sampling sites, followed by the SAS Super 90 and the Andersen two-stage impactor. The number of bacteria retrieved by the RCS Plus was significantly less than those retrieved by the other samplers. Among the predominant bacterial genera retrieved by all samplers were Staphylococcus, Bacillus, Corynebacterium, Micrococcus, and Streptococcus.
Passive sampler for PM10-2.5 aerosol.
Leith, David; Sommerlatt, Darrell; Boundy, Maryanne G
2007-03-01
This study investigates the use of a small passive sampler for aerosol particles to determine particulate matter (PM)10-2.5 concentrations in outdoor air. The passive sampler collects particles by gravity, diffusion, and convective diffusion onto a glass coverslip that is then examined with an optical microscope; digital images are processed with free software and the resultant PM10-2.5 concentrations determined. Both the samplers and the analyses are relatively inexpensive. Passive samplers were collocated with Federal Reference Method (FRM) samplers in Chapel Hill, NC; Phoenix, AZ; and Birmingham, AL; for periods from 5 to 15 days. Particles consisted primarily of inorganic dusts at some sites and a mix of industrial and inorganic materials at other sites. Measured concentrations ranged from < 10 microg/m3 to approximately 40 microg/m3. Overall, PM10-2.5 concentrations measured with the passive samplers were within approximately 1 standard deviation of concentrations measured with the FRM samplers. Concentrations determined with passive samplers depend on assumptions about particle density and shape factors and may also depend somewhat on local wind speed and turbulence; accurate values for these parameters may not be known. The degree of agreement between passive and FRM concentrations measured here suggests that passive measurements may not be overly dependent on accurate knowledge of these parameters.
Evaluation of Bio-VOC Sampler for Analysis of Volatile Organic Compounds in Exhaled Breath
Kwak, Jae; Fan, Maomian; Harshman, Sean W.; Garrison, Catherine E.; Dershem, Victoria L.; Phillips, Jeffrey B.; Grigsby, Claude C.; Ott, Darrin K.
2014-01-01
Monitoring volatile organic compounds (VOCs) from exhaled breath has been used to determine exposures of humans to chemicals. Prior to analysis of VOCs, breath samples are often collected with canisters or bags and concentrated. The Bio-VOC breath sampler, a commercial sampling device, has been recently introduced to the market with growing use. The main advantage for this sampler is to collect the last portion of exhaled breath, which is more likely to represent the air deep in the lungs. However, information about the Bio-VOC sampler is somewhat limited. Therefore, we have thoroughly evaluated the sampler here. We determined the volume of the breath air collected in the sampler was approximately 88 mL. When sampling was repeated multiple times, with the succeeding exhalations applied to a single sorbent tube, we observed linear relationships between the normalized peak intensity and the number of repeated collections with the sampler in many of the breath VOCs detected. No moisture effect was observed on the Tenax sorbent tubes used. However, due to the limitation in the collection volume, the use of the Bio-VOC sampler is recommended only for detection of VOCs present at high concentrations unless repeated collections of breath samples on the sampler are conducted. PMID:25532709
A rotating bluff-body disc for reduced variability in wind tunnel aerosol studies.
Koehler, Kirsten A; Anthony, T Renee; van Dyke, Michael; Volckens, John
2011-01-01
A rotating bluff-body disc (RBD) was developed to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. The RBD is designed to rotate eight personal aerosol samplers around a circular path in a forward-facing plane aligned with the wind tunnel cross section. Rotation of the RBD allows each sampler to traverse an identical path about the wind tunnel cross section, which reduces the effects of spatial heterogeneity associated with dispersing supermicron aerosol in low-velocity wind tunnels. Samplers are positioned on the face of the RBD via sampling ports, which connect to an air manifold on the back of the disc. Flow through each sampler was controlled with a critical orifice or needle valve, allowing air to be drawn through the manifold with a single pump. A metal tube, attached to this manifold, serves as both the axis of rotation and the flow conduction path (between the samplers and the vacuum source). Validation of the RBD was performed with isokinetic samplers and 37-mm cassettes. For facing-the-wind tests, the rotation of the RBD significantly decreased intra-sampler variability when challenged with particle diameters from 1 to 100 μm. The RBD was then employed to determine the aspiration efficiency of Institute of Occupational Medicine (IOM) personal samplers under a facing-the-wind condition. Operation of IOM samplers on the RBD reduced the between-sampler variability for all particle sizes tested.
Field evaluation of personal sampling methods for multiple bioaerosols.
Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine
2015-01-01
Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.
Megchelenbrink, Wout; Huynen, Martijn; Marchiori, Elena
2014-01-01
Constraint-based models of metabolic networks are typically underdetermined, because they contain more reactions than metabolites. Therefore the solutions to this system do not consist of unique flux rates for each reaction, but rather a space of possible flux rates. By uniformly sampling this space, an estimated probability distribution for each reaction's flux in the network can be obtained. However, sampling a high dimensional network is time-consuming. Furthermore, the constraints imposed on the network give rise to an irregularly shaped solution space. Therefore more tailored, efficient sampling methods are needed. We propose an efficient sampling algorithm (called optGpSampler), which implements the Artificial Centering Hit-and-Run algorithm in a different manner than the sampling algorithm implemented in the COBRA Toolbox for metabolic network analysis, here called gpSampler. Results of extensive experiments on different genome-scale metabolic networks show that optGpSampler is up to 40 times faster than gpSampler. Application of existing convergence diagnostics on small network reconstructions indicate that optGpSampler converges roughly ten times faster than gpSampler towards similar sampling distributions. For networks of higher dimension (i.e. containing more than 500 reactions), we observed significantly better convergence of optGpSampler and a large deviation between the samples generated by the two algorithms. optGpSampler for Matlab and Python is available for non-commercial use at: http://cs.ru.nl/~wmegchel/optGpSampler/.
La Torre, Giuseppe; Sestili, Cristina; Mannocci, Alice; Sinopoli, Alessandra; De Paolis, Massimiliano; De Francesco, Sara; Rapaccini, Laura; Barone, Marco; Iodice, Valentina; Lojodice, Bruno; Sernia, Sabina; De Sio, Simone; Del Cimmuto, Angela; De Giusti, Maria
2018-01-19
The aim of this work is investigate relationship between health-related quality of life and work-related stress and the impact of gender, education level, and age on this relationship. A cross-sectional study was conducted among workers of various setting in Rome and Frosinone. Work-related stress was measured with a demand-control questionnaire and health-related functioning by SF (short form)-12 health survey. There were 611 participants. Men reported high mental composite summary (MCS) and physical composite summary (PCS). In multivariate analysis age, gender ( p < 0.001) and job demand (0.045) predicted low PCS. Low MCS predicted poor PCS. Job demand and educational level resulted negatively associated with MCS. In an analysis stratified for age, gender, and educational level, gender and age resulted effect modifier for MCS, gender and education level for PCS. In women increase of decision latitude predict ( p = 0.001) an increase in MCS; a low job demand predict high MCS in male ( p ≤ 0.001). In younger workers, a lower level of job demand predicted high MCS (<0.001). For PCS, gender and education level resulted effect modifier. In women, high decision latitude predicted higher PCS ( p = 0.001) and lower level of job demand results in higher PCS ( p ≤ 0.001). Higher educational level resulted predictor of low PCS. Management of risk about work-related stress should consider socio-demographic factors.
McNally, Kelly A.; Bangert, Barbara; Dietrich, Ann; Nuss, Kathy; Rusin, Jerome; Wright, Martha; Taylor, H. Gerry; Yeates, Keith Owen
2013-01-01
Objective To examine the relative contributions of injury characteristics and non-injury child and family factors as predictors of postconcussive symptoms (PCS) following mild traumatic brain injury (TBI) in children. Methods Participants were 8- to 15-year-old children, 186 with mild TBI and 99 with mild orthopedic injuries (OI). Parents and children rated PCS shortly after injury and at 1, 3, and 12 months post-injury. Hierarchical regression analyses were conducted to predict PCS from (1) demographic variables; (2) pre-morbid child factors (WASI IQ; WRAT-3 Reading; Child Behavior Checklist; ratings of pre-injury PCS); (3) family factors (Family Assessment Device General Functioning Scale; Brief Symptom Inventory; and Life Stressors and Social Resources Inventory); and (4) injury group (OI, mild TBI with loss of consciousness [LOC] and associated injuries [AI], mild TBI with LOC but without AI, mild TBI without LOC but with AI, and mild TBI without LOC or AI) Results Injury group predicted parent and child ratings of PCS but showed a decreasing contribution over time. Demographic variables consistently predicted symptom ratings across time. Premorbid child factors, especially retrospective ratings of premorbid symptoms, accounted for the most variance in symptom ratings. Family factors, particularly parent adjustment, consistently predicted parent, but not child, ratings of PCS. Conclusions Injury characteristics predict PCS in the first months following mild TBI but show a decreasing contribution over time. In contrast, non-injury factors are more consistently related to persistent PCS. PMID:23356592
Richmond, Sarah A; Willan, Andrew R; Rothman, Linda; Camden, Andi; Buliung, Ron; Macarthur, Colin; Howard, Andrew
2014-06-01
To perform a more sophisticated analysis of previously published data that advances the understanding of the efficacy of pedestrian countdown signal (PCS) installation on pedestrian-motor vehicle collisions (PMVCs), in the city of Toronto, Canada. This is an updated analysis of the same dataset from Camden et al. A quasi-experimental design was used to evaluate the effect of PCS on PMVC. A Poisson regression analysis, using a one-group comparison of PMVC, pre-PCS installation to post-PCS installation was used, controlling for season and temporal effects. The outcome was the frequency of reported PMVC (January 2000-December 2009). Similar models were used to analyse specific types of collisions defined by age of pedestrian, injury severity, and pedestrian and vehicle action. Incidence rate ratios with 95% CI are presented. This analysis included 9262 PMVC, 2760 during or after PCS installation, at 1965 intersections. There was a 26% increase in the rate of collisions, pre to post-PCS installation (incidence rate ratio=1.26, 95% CI 1.11 to 1.42). The installation of PCS at 1965 signalised intersections in the city of Toronto resulted in an increase in PMVC rates post-PCS installation. PCSs may have an unintended consequence of increasing pedestrian-motor vehicle collisions in some settings. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Towards an Understanding of the Function of the Phytochelatin Synthase of Schistosoma mansoni
Rigouin, Coraline; Nylin, Elyse; Cogswell, Alexis A.; Schaumlöffel, Dirk; Dobritzsch, Dirk; Williams, David L.
2013-01-01
Phytochelatin synthase (PCS) is a protease-like enzyme that catalyzes the production of metal chelating peptides, the phytochelatins, from glutathione (GSH). In plants, algae, and fungi phytochelatin production is important for metal tolerance and detoxification. PCS proteins also function in xenobiotic metabolism by processing GSH S-conjugates. The aim of the present study is to elucidate the role of PCS in the parasitic worm Schistosoma mansoni. Recombinant S. mansoni PCS proteins expressed in bacteria could both synthesize phytochelatins and hydrolyze various GSH S-conjugates. We found that both the N-truncated protein and the N- and C-terminal truncated form of the enzyme (corresponding to only the catalytic domain) work through a thiol-dependant and, notably, metal-independent mechanism for both transpeptidase (phytochelatin synthesis) and peptidase (hydrolysis of GSH S-conjugates) activities. PCS transcript abundance was increased by metals and xenobiotics in cultured adult worms. In addition, these treatments were found to increase transcript abundance of other enzymes involved in GSH metabolism. Highest levels of PCS transcripts were identified in the esophageal gland of adult worms. Taken together, these results suggest that S. mansoni PCS participates in both metal homoeostasis and xenobiotic metabolism rather than metal detoxification as previously suggested and that the enzyme may be part of a global stress response in the worm. Because humans do not have PCS, this enzyme is of particular interest as a drug target for schistosomiasis. PMID:23383357
Ho, K L; Pometto, A L; Hinz, P N
1997-01-01
Four customized bioreactors, three with plastic composite supports (PCS) and one with suspended cells (control), were operated as repeated-batch fermentors for 66 days at pH 5 and 37 degrees C. The working volume of each customized reactor was 600 ml, and each reactor's medium was changed every 2 to 5 days for 17 batches. The performance of PCS bioreactors in long-term biofilm repeated-batch fermentation was compared with that of suspended-cell bioreactors in this research. PCS could stimulate biofilm formation, supply nutrients to attached and free suspended cells, and reduce medium channelling for lactic acid production. Compared with conventional repeated-batch fermentation, PCS bioreactors shortened the lag time by threefold (control, 11 h; PCS, 3.5 h) and sixfold (control, 9 h; PCS, 1.5 h) at yeast extract concentrations of 0.4 and 0.8% (wt/vol), respectively. They also increased the lactic acid productivity of Lactobacillus casei subsp. rhamnosus (ATCC 11443) by 40 to 70% and shortened the total fermentation time by 28 to 61% at all yeast extract concentrations. The fastest productivity of the PCS bioreactors (4.26 g/liter/h) was at a starting glucose concentration of 10% (wt/vol), whereas that of the control (2.78 g/liter/h) was at 8% (wt/vol). PCS biofilm lactic acid fermentation can drastically improve the fermentation rate with reduced complex-nutrient addition. PMID:9212403
NASA Astrophysics Data System (ADS)
Takahashi, Y.; Hata, T.; Nishida, H.
2017-12-01
In normal coring of deep marine sediments, the sampled cores are exposed to the pressure of the atmosphere, which results in dissociation of gas-hydrates and might change microbial diversity. In this study, we analyzed microbial composition in methane hydrate-bearing sediment core sampled and preserved by Hybrid-PCS (Pressure Coring System). We sliced core into three layers; (i) outside layer, which were most affected by drilling fluids, (ii) middle layer, and (iii) inner layer, which were expected to be most preserved as the original state. From each layer, we directly extracted DNA, and amplified V3-V4 region of 16S rRNA gene. We determined at least 5000 of nucleotide sequences of the partial 16S rDNA from each layer by Miseq (Illumina). In the all layers, facultative anaerobes, which can grow with or without oxygen because they can metabolize energy aerobically or anaerobically, were detected as majority. However, the genera which are often detected anaerobic environment is abundant in the inner layer compared to the outside layer, indicating that condition of drilling and preservation affect the microbial composition in the deep marine sediment core. This study was conducted as a part of the activity of the Research Consortium for Methane Hydrate Resources in Japan [MH21 consortium], and supported by JOGMEC (Japan Oil, Gas and Metals National Corporation). The sample was provided by AIST (National Institute of Advanced Industrial Science and Technology).
Field comparison of air sampling methods for monomeric and polymeric 1,6-hexamethylene diisocyanate.
Thomasen, Jennifer M; Fent, Kenneth W; Reeb-Whitaker, Carolyn; Whittaker, Stephen G; Nylander-French, Leena A
2011-03-01
This study was to critically compared 13 different air samplers for their ability to monitor air exposures to monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI) in the automotive refinishing industry. Using both fast- and slow-drying clearcoat, we tested the following types of samplers: single- and dual-stage 37-mm polypropylene (PP) and polystyrene (PS) samplers (open- and closed-face), IOM (with plastic and stainless steel inserts), OSHA42, IsoChek, and WA-DOSH samplers. Midget impingers with frit were used as reference samplers. We observed the PP, PS, and IOM samplers to measure greater levels of HDI monomer and biuret when a fast-drying clearcoat was applied compared with a slow-drying clearcoat. When a slow-drying clearcoat was applied, the open-face PP and PS samplers measured significantly more monomeric and polymeric HDI (2-fold; p < 0.003) than the closed-face PP and PS samplers. We determined that significantly more monomeric and polymeric HDI were measured by impingers (1.3-1.9-fold) compared with single-stage PP/PS (N = 59), dual-stage PP/PS (N = 59), or IOM (N = 24) samplers. However, when stratified by cassette characteristics, the open-face single-stage PP and PS samplers performed equally to the impingers for HDI monomer when a fast-drying clearcoat was applied, and for all analytes when a slow-drying clearcoat was applied. Significantly higher HDI monomer concentrations (1.2-3.1-fold; p = 0.001) were measured with OSHA42 compared with the impinger. The IsoChek did not detect HDI monomer, and of the three samplers analyzed by laboratories other than UNC (i.e., OSHA42, IsoChek, and WA-DOSH), the WA-DOSH was in the best agreement with the impingers. The influence of clearcoat drying time on the sampler's ability to measure monomeric and polymeric HDI emphasizes the importance of the speciation of diisocyanates in chemical analysis and the careful consideration for the selection of the air sampler to be used when measuring exposures during automotive spray painting.
Banerjee, Tanushree; Meyer, Timothy W.; Shafi, Tariq; Hostetter, Thomas H.; Melamed, Michal; Zhu, Yunnuo; Powe, Neil R.
2017-01-01
Abstract The uremic syndrome is attributed to progressive retention of compounds that, under normal conditions, are excreted by the healthy kidneys. p-cresol sulfate (PCS), a prototype protein-bound uremic retention solute, has been shown to exert toxic effects in vitro. Recent studies have identified relations between increased levels of PCS and indoxyl sulfate (IS) and adverse clinical outcomes in hemodialysis patients. We explored the relationship between free and total PCS and IS with infection-related hospitalizations (IH) and septicemia in 2 cohorts, Choices for Healthy Outcomes in Caring for end-stage renal disease (ESRD) Study (CHOICE) and Hemodialysis Study (HEMO). We measured free and total levels of PCS and IS in stored specimens in CHOICE, a cohort of 464 incident hemodialysis patients enrolled in 1995 to 1998 and followed for an average of 3.4 years and in a prevalent dialysis cohort of 495 patients enrolled in HEMO from 1995 to 2000 and followed for an average of 4.4 years. We measured free PCS and IS using mass spectroscopy. The 2 cohorts were linked to United States Renal Data System (USRDS) Medicare billing records to ascertain IH over follow-up. We examined the association of free and total levels of PCS and IS with IH and septicemia using multilevel Poisson regression models adjusted for demographics, comorbidities, clinical factors, and laboratory tests including residual kidney function. We stratified patients a priori based on gastrointestinal (GI) disease as PCS and IS are produced in colon. In CHOICE, highest tertile of free PCS in multivariable model was associated with 50% higher risk of IH [95% CI = 1.01–2.23] compared with lowest tertile in patients with no-GI disease. A significant trend was noted between greater levels of free PCS and septicemia in no-GI disease group in both cohorts, while no association was noted in GI disease group. Total PCS concentrations were not associated with either IH or septicemia in either cohort. No significant risk of IH or septicemia was noted with higher levels of free or total IS in either GI or no-GI disease group. These results suggest an association between higher concentrations of free PCS and infection-related and sepsis-related hospitalizations in hemodialysis patients. Better methods of dialysis should be developed to evaluate the utility of removing PCS and its effect on the outcome and also therapies to decrease gastrointestinal tract production of uremic solutes. PMID:28178126
The paper compares the particle size distribution of heavy-duty diesel exhaust using a dilution tail-pipe sampler and an in-plume sampler during on-road operation. EPA's On-road Diesel Emissions Characterization Facility, modified to incorporate particle measurement instrumentat...
Nilsen, Elena B.; Alvarez, David A.
2011-01-01
Significant Findings Water and sediment quality monitoring was conducted before and after the removal of a piling field located in Coal Creek Slough near Longview, Washington. Passive chemical samplers and continuous water-quality monitoring instruments were deployed at the piling removal site, Coal Creek Slough Site 1 (CCS1), and at a comparison site, Coal Creek Slough Site 2 (CCS2), before (2008) and after (2009) piling removal. Surface and subsurface (core) sediment samples were collected before and after piling removal and were analyzed for grain size, organic carbon content, and chemicals of concern. Significant findings from this study include: * Phenanthrene was the only compound detected in wood piling samples analyzed for a large suite of semivolatile organic compounds and polycyclic aromatic hydrocarbons (PAHs). Metals potentially associated with wood treatment were detected in the wood piling samples at low concentrations. * Organic carbon was slightly lower in core samples from CCS1 in pre-removal (2008) and post-removal (2009) samples than in surface samples from both sites in both years. * Grain-size class distributions were relatively uniform between sites and years. * Thirty-four out of 110 chemicals of concern were detected in sediments. Eight of those detected were anthropogenic waste indicator (AWI) compounds, 18 were PAHs, 4 were sterols, and 4 were metals potentially associated with wood treatment. * Nearly all reported concentrations of chemicals of concern in sediments are qualified as estimates, primarily due to interferences in extracts resulting from complex sample matrices. Indole, perylene, and fluoranthene are reported without qualification for some of the samples, and the metals are reported without qualification for all samples. * The highest frequency of detection of chemicals of concern was seen in the pre-removal surface samples at both sites. * AWI compounds were detected less frequently and at lower concentrations during the post-removal sampling compared to the pre-removal sampling. * Several PAHs were detected at relatively high concentrations in core samples, likely indicating historical sources. * Most commonly detected PAHs in sediments were 2,6-dimethylnaphthalene, fluoranthene, perylene, and pyrene. * Most commonly detected AWIs in sediments were 3-methyl-1h-indole (skatol), acetophenone, indole, phenol, and paracresol. * Sedimentary concentrations of perylene exceeded available sediment quality guidelines. Perylene is widespread in the environment and has large potential natural sources in addition to its anthropogenic sources. * Concentrations of metals did not exceed sediment quality guidelines. * Multiple organochlorine pesticides, both banned and currently used, were detected at each site using passive samplers. * Commonly detected pesticides included hexachlorobenzene, pentachloroanisole (a degradation product of pentachlorophenol), diazinon, cis-chlordane, endosulfan, DDD, and endosulfan sulfate. * PBDE concentrations detected in passive sampler extracts were less than the method detection limit at all sites with the exception of PBDE-99, detected at a concentration less than the reporting limit. * The fragrance galaxolide was detected at a concentration greater than the method detection limit. * Common PAHs, such as phenanthrene, fluoranthene, and pyrene, were detected in every passive sampler. * Dissolved oxygen concentration was slightly higher at site CCS1 compared to site CCS2 in both years. * Overall, there was no systematic increase in chemicals of concern at the restoration site during post-removal monitoring compared to conditions during pre-removal monitoring. Any immediate, short-duration effects of piling removal on water quality could not be determined because monitoring was not conducted during the removal.
Fabrication of 3-D Photonic Band Gap Crystals Via Colloidal Self-Assembly
NASA Technical Reports Server (NTRS)
Subramaniam, Girija; Blank, Shannon
2005-01-01
The behavior of photons in a Photonic Crystals, PCs, is like that of electrons in a semiconductor in that, it prohibits light propagation over a band of frequencies, called Photonic Band Gap, PBG. Photons cannot exist in these band gaps like the forbidden bands of electrons. Thus, PCs lend themselves as potential candidates for devices based on the gap phenomenon. The popular research on PCs stem from their ability to confine light with minimal losses. Large scale 3-D PCs with a PBG in the visible or near infra red region will make optical transistors and sharp bent optical fibers. Efforts are directed to use PCs for information processing and it is not long before we can have optical integrated circuits in the place of electronic ones.
Natural and cross-inducible anti-SIV antibodies in Mauritian cynomolgus macaques
Li, Hongzhao; Nykoluk, Mikaela; Li, Lin; Liu, Lewis R.; Omange, Robert W.; Soule, Geoff; Schroeder, Lukas T.; Toledo, Nikki; Kashem, Mohammad Abul; Correia-Pinto, Jorge F.; Liang, Binhua; Schultz-Darken, Nancy; Alonso, Maria J.; Whitney, James B.; Plummer, Francis A.
2017-01-01
Cynomolgus macaques are an increasingly important nonhuman primate model for HIV vaccine research. SIV-free animals without pre-existing anti-SIV immune responses are generally needed to evaluate the effect of vaccine-induced immune responses against the vaccine epitopes. Here, in order to select such animals for vaccine studies, we screened 108 naïve female Mauritian cynomolgus macaques for natural (baseline) antibodies to SIV antigens using a Bio-Plex multiplex system. The antigens included twelve 20mer peptides overlapping the twelve SIV protease cleavage sites (-10/+10), respectively (PCS peptides), and three non-PCS Gag or Env peptides. Natural antibodies to SIV antigens were detected in subsets of monkeys. The antibody reactivity to SIV was further confirmed by Western blot using purified recombinant SIV Gag and Env proteins. As expected, the immunization of monkeys with PCS antigens elicited anti-PCS antibodies. However, unexpectedly, antibodies to non-PCS peptides were also induced, as shown by both Bio-Plex and Western blot analyses, while the non-PCS peptides do not share sequence homology with PCS peptides. The presence of natural and vaccine cross-inducible SIV antibodies in Mauritian cynomolgus macaques should be considered in animal selection, experimental design and result interpretation, for their best use in HIV vaccine research. PMID:28982126
Podda, Gian Marco; Pugliano, Mariateresa; Femia, Eti Alessandra; Mezzasoma, Anna Maria; Gresele, Paolo; Carpani, Giovanni; Cattaneo, Marco
2012-07-01
Spuriously low platelet counts (PCs) can be observed in normal blood samples anticoagulated with ethylenediamine tetra-acetic acid (EDTA)and, much less frequently, with citrate-tris-pyridossalphosphate (CPT),due to time-dependent in vitro platelet agglutination. Accuracy in PC determination is essential as PC is one of the parameters that usually guides treatment for thrombocytopenic patients. PCs of 93 thrombocy to penic patients were measured in EDTA- or CPT-anticoagulated blood samples immediately after sampling (t0) and 90 min (t90) after storage at room temperature. The presence of platelet agglutinates in blood samples was determined by examining blood smears using optical microscopy.PCs decreased at t90 with both anticoagulants. Platelet agglutinates were present at t90 in 27% of EDTA-samples vs. 2% of CPT-samples with decreased PCs (P < 0.001). Based on PCs in EDTA-samples, 15 patients (16%) shifted from a lower bleeding risk at t0 to a higher bleeding risk category at t90 (P 5 0.019), compared to 5 (5%) patients, based on PCs in CPT-samples. Therefore, time-dependent in vitro platelet agglutination in EDTA-blood samples may cause underestimation of PCs in thrombocytopenic patients, possibly leading to improper management.
Erdem, S. Sibel; Nesterova, Irina V.; Soper, Steven A.; Hammer, Robert P.
2009-01-01
Phthalocyanines (Pcs) are excellent candidates for use as fluors for near-infrared (near-IR) fluorescent tagging of biomolecules for a wide variety of bioanalytical applications. Mono-functionalized Pcs, having two different types of peripheral substitutents; one for covalent conjugation of the Pc to biomolecules and others to improve the solubility of the macrocycle, ideally suit for the desired applications. To date, difficulties faced during the purification of the mono-functionalized Pcs limited their usage in various types of applications. Herein are reported a new synthetic method for rapid synthesis of the target Pcs and bioconjugation techniques for labeling of the oligonucleotides with the near-IR flours. A novel synthetic route was developed utilizing a hydrophilic, polyethylene glycol-based (PEG) support with an acid labile Rink Amide linker. The Pcs were functionalized with an amine group for covalent conjugation purposes and were decorated with short PEG chains, serving as solubilizing groups. Mwave-assisted solid-phase synthetic method was successfully applied to obtain pure asymmetrically-substituted mono-amine functionalized Pcs in a short period of time. Three different bioconjugation techniques, reductive amination, amidation and Huisgen cycloaddition, were employed for covalent conjugation of Pcs to oligonucleotides. The described μwave-assisted bioconjugation methods give an opportunity to synthesize and isolate the Pc-oligonucleotide conjugate in a few hours. PMID:19911767
Gonsalves, Wilson I.; Rajkumar, S. Vincent; Dispenzieri, Angela; Dingli, David; Timm, Michael M.; Morice, William G.; Lacy, Martha Q.; Buadi, Francis K.; Go, Ronald S.; Leung, Nelson; Kapoor, Prashant; Hayman, Suzanne R.; Lust, John A.; Russell, Stephen J.; Zeldenrust, Steven R.; Hwa, Lisa; Kourelis, Taxiarchis V.; Kyle, Robert A.; Gertz, Morie A.; Kumar, Shaji K.
2017-01-01
The presence of high numbers of circulating clonal plasma cells (cPCs) in patients with smoldering multiple myeloma (SMM), detected by a slide-based immunofluorescence assay, has been associated with a shorter time to progression (TTP) to multiple myeloma (MM). The significance of quantifying cPCs via multiparameter flow cytometry, a much more readily available diagnostic modality, in patients with SMM has not been evaluated. This study evaluated 100 patients with a known or new diagnosis of SMM who were seen at the Mayo Clinic, Rochester from January 2008 until December 2013. Patients with ≥ 150 cPCs (N = 9) were considered to have high number of cPCs based on the 97% specificity and 78% PPV of progression to MM within 2 years of cPC assessment. The median TTP of patients with ≥ 150 cPCs was 9 months compared to not reached for patients with < 150 cPCs (P < 0.001). Thus, quantification of cPCs via multiparametric flow cytometry identifies patients with SMM at very high risk of progression to MM within 2 years and warrants confirmation in larger studies. In the future, this may allow reclassification of such patients as having MM requiring therapy prior to them enduring end-organ damage. PMID:27457702
Continuous lactic acid fermentation using a plastic composite support biofilm reactor.
Cotton, J C; Pometto, A L; Gvozdenovic-Jeremic, J
2001-12-01
An immobilized-cell biofilm reactor was used for the continuous production of lactic acid by Lactobacillus casei subsp. rhamnosus (ATCC 11443). At Iowa State University, a unique plastic composite support (PCS) that stimulates biofilm formation has been developed. The optimized PCS blend for Lactobacillus contains 50% (wt/wt) agricultural products [35% (wt/wt) ground soy hulls, 5% (wt/wt) soy flour, 5% (wt/wt) yeast extract, 5% (wt/wt) dried bovine albumin, and mineral salts] and 50% (wt/wt) polypropylene (PP) produced by high-temperature extrusion. The PCS tubes have a wall thickness of 3.5 mm, outer diameter of 10.5 mm, and were cut into 10-cm lengths. Six PCS tubes, three rows of two parallel tubes, were bound in a grid fashion to the agitator shaft of a 1.2-1 vessel for a New Brunswick Bioflo 3000 fermentor. PCS stimulates biofilm formation, supplies nutrients to attached and suspended cells, and increases lactic acid production. Biofilm thickness on the PCS tubes was controlled by the agitation speed. The PCS biofilm reactor and PP control reactor achieved optimal average production rates of 9.0 and 5.8 g l(-1) h(-1), respectively, at 0.4 h(-1) dilution rate and 125-rpm agitation with yields of approximately 70%.
Batorowicz, Beata; King, Gillian; Vane, Freda; Pinto, Madhu; Raghavendra, Parimala
2017-06-01
Participation has a subjective and private dimension, and so it is important to hear directly from youth about their experiences in various activity settings, the places where they "do things" and interact with others. To meet this need, our team developed the Self-Reported Experiences of Activity Settings (SEAS) measure, which demonstrated good-to-excellent measurement properties. To address the needs of youth who could benefit from graphic symbol support, the SEAS-PCS TM , 1 was created. The purpose of this paper is to describe the development of SEAS-PCS and the preliminary study that explores the equivalency of the SEAS and SEAS-PCS. The SEAS and SEAS-PCS were compared in terms of the equivalency of meaning of stimulus items by 11 professionals and five adults who used augmentative and alternative communication, were familiar with PCS, and were fluent readers. Out of 22 items, 68% were rated as highly similar on a 5-point scale (M = 4.14; SD = .70; mdn = 4; range: 2.81-5.00). Subsequently, the 32% of the SEAS-PCS items that were rated below 4 were modified based on the participants' specific comments. Further work is required to validate the SEAS-PCS. The next step could involve exploring the views of youth who use AAC.
Kandouz, Sakina; Mohamed, Ali Shendi; Zheng, Yishan; Sandeman, Susan; Davenport, Andrew
2016-10-01
Introduction Indoxyl sulfate (IS) and p cresyl sulfate (PCS) are protein bound toxins which accumulate with chronic kidney disease. Haemodiafiltration (HDF) increases middle molecule clearances and has been suggested to increase IS and PCS clearance. We therefore wished to establish whether higher convective clearances with HDF would reduce IS and PCS concentrations. Methods We measured total plasma IS and PCS in a cohort of 138 CKD5d patients treated by On-line HDF (Ol-HDF), by high pressure liquid chromatography. Findings Mean patient age was 64.6 ± 16.5 years, 60.1% male, 57.3% diabetic, median dialysis vintage 25.9 months (12.4-62.0). The mean ICS concentration was 79.8 ± 56.4 umol/L and PCS 140.3 ± 101.8 umol/L. On multivariate analysis, IS was associated with serum albumin (β 4.31,P < 0.001), and negatively with residual renal function (β-4.1,P = 0.02) and vegetarian diet(β-28.3, P = 0.048) and PCS negatively with log C reactive protein (β-75.8, P < 0.001) and vegetarian diet (β-109, P = 0.001). Vegetarian patients had lower IS and PCS levels (median 41.5 (24.2-71.9) vs. 78.1 (49.5-107.5) and PCS (41.6 (14.2-178.3) vs. 127.3 (77.4-205.6) µmol/L, respectively, P < 0.05. Vegetarian patients had lower preOl-HDF serum urea, and phosphate (13.8 ±3.8 vs. 18.4 ± 5.2 mmol/L, and 1.33 ± 0.21 vs. 1.58 ± 0.45 mmol/L), and estimated urea nitrogen intake (1.25 ± 0.28 vs. 1.62 ± 0.5 g/kg/day), respectively, all P < 0.05. Discussion Plasma IS and PCS concentrations were not lower with Ol-HDF compared to previous studies in haemodialysis patients. However those eating a vegetarian diet had reduced IS and PCS concentrations. Although this could be due to differences in dietary protein intake, a vegetarian diet may also potentially reduce IS and PCS production by the intestinal microbiome. © 2016 International Society for Hemodialysis.
Determination of inadvertent atrial capture during para-Hisian pacing.
Obeyesekere, Manoj; Leong-Sit, Peter; Skanes, Allan; Krahn, Andrew; Yee, Raymond; Gula, Lorne J; Bennett, Matthew; Klein, George J
2011-08-01
Inadvertent capture of the atrium will lead to spurious results during para-Hisian pacing. We sought to establish whether the stimulation-to-atrial electrogram interval at the proximal coronary sinus (stim-PCS) or high right atrium (stim-HRA) could signal inadvertent atrial capture. Para-Hisian pacing with and without intentional atrial capture was performed in 31 patients. Stim-HRA and stim-PCS intervals were measured with atrial capture, His plus para-Hisian ventricular (H+V) capture, and para-Hisian ventricular (V) capture alone. The mean stim-HRA interval was significantly shorter with atrial capture (66 ± 18 ms) than with H+V (121 ± 27 ms, P < 0.001) or V capture alone (174 ± 38 ms, P < 0.001). The mean stim-PCS interval was significantly shorter with atrial capture (51 ± 16 ms) than with H+V (92 ± 22 ms, P<0.001) or V capture alone (146 ± 33 ms, P < 0.001). A stim-PCS < 60 ms (stim-HRA < 70 ms) was observed only with atrial capture. A stim-PCS >90 ms (stim-HRA >100 ms) was observed only in the absence of atrial capture. A stim-HRA of < 85 ms was highly specific and stim-PCS of < 85 ms highly sensitive at identifying atrial capture. Stim-HRA intervals of 75 to 97 ms and stim-PCS intervals of 65 to 88 ms were observed with either atrial, His, or para-Hisian ventricular capture without atrial capture. In this overlap zone, all patients demonstrated a stim-PCS or stim-HRA interval prolongation of at least 20 ms when the catheter was advanced to avoid deliberate atrial pacing. The QRS morphology was of limited value in distinguishing atrial capture due to concurrent ventricular or H+V capture, as observed in 20 of 31 (65%) patients. Stim-PCS and stim-HRA intervals can be used to monitor for inadvertent atrial capture during para-Hisian pacing. A stim-PCS < 60 ms (or stim-HRA < 70 ms) and stim-PCS > 90 ms (or stim-HRA > 100 ms) were observed only with and without atrial capture, respectively, but there was significant overlap between these values. Deliberate atrial capture and loss of capture reliably identifies atrial capture regardless of intervals.
NASA Astrophysics Data System (ADS)
Melymuk, Lisa; Bohlin-Nizzetto, Pernilla; Prokeš, Roman; Kukučka, Petr; Přibylová, Petra; Vojta, Šimon; Kohoutek, Jiří; Lammel, Gerhard; Klánová, Jana
2017-10-01
Degradation of semivolatile organic compounds (SVOCs) occurs naturally in ambient air due to reactions with reactive trace gases (e.g., ozone, NOx). During air sampling there is also the possibility for degradation of SVOCs within the air sampler, leading to underestimates of ambient air concentrations. We investigated the possibility of this sampling artifact in commonly used active and passive air samplers for seven classes of SVOCs, including persistent organic pollutants (POPs) typically covered by air monitoring programs, as well as SVOCs of emerging concern. Two active air samplers were used, one equipped with an ozone denuder and one without, to compare relative differences in mass of collected compounds. Two sets of passive samplers were also deployed to determine the influence of degradation during longer deployment times in passive sampling. In active air samplers, comparison of the two sampling configurations suggested degradation of particle-bound polycyclic aromatic hydrocarbons (PAHs), with concentrations up to 2× higher in the denuder-equipped sampler, while halogenated POPs did not have clear evidence of degradation. In contrast, more polar, reactive compounds (e.g., organophosphate esters and current use pesticides) had evidence of losses in the sampler with denuder. This may be caused by the denuder itself, suggesting sampling bias for these compounds can be created when typical air sampling apparatuses are adapted to limit degradation. Passive air samplers recorded up to 4× higher concentrations when deployed for shorter consecutive sampling periods, suggesting that within-sampler degradation may also be relevant in passive air monitoring programs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leishear, R.; Thaxton, D.; Minichan, R.
A sampling tool was required to evaluate residual activity ({mu}Curies per square foot) on the inner wall surfaces of underground nuclear waste storage tanks. The tool was required to collect a small sample from the 3/8 inch thick tank walls. This paper documents the design, testing, and deployment of the remotely operated sampling device. The sampler provides material from a known surface area to estimate the overall surface contamination in the tank prior to closure. The sampler consisted of a sampler and mast assembly mast assembly, control system, and the sampler, or end effector, which is defined as the operatingmore » component of a robotic arm. The mast assembly consisted of a vertical 30 feet long, 3 inch by 3 inch, vertical steel mast and a cantilevered arm hinged at the bottom of the mast and lowered by cable to align the attached sampler to the wall. The sampler and mast assembly were raised and lowered through an opening in the tank tops, called a riser. The sampler is constructed of a mounting plate, a drill, springs to provide a drive force to the drill, a removable sampler head to collect the sample, a vacuum pump to draw the sample from the drill to a filter, and controls to operate the system. Once the sampler was positioned near the wall, electromagnets attached it to the wall, and the control system was operated to turn on the drill and vacuum to remove and collect a sample from the wall. Samples were collected on filters in removable sampler heads, which were readily transported for further laboratory testing.« less
A new sampler for stratified lagoon chemical and microbiological assessments.
McLaughlin, M R; Brooks, J P; Adeli, A
2014-07-01
A sampler was needed for a spatial and temporal study of microbial and chemical stratification in a large swine manure lagoon that was known to contain zoonotic bacteria. Conventional samplers were limited to collections of surface water samples near the bank or required a manned boat. A new sampler was developed to allow simultaneous collection of multiple samples at different depths, up to 2.3 m, without a manned boat. The sampler was tethered for stability, used remote control (RC) for sample collection, and accommodated rapid replacement of sterile tubing modules and sample containers. The sampler comprised a PVC pontoon with acrylic deck and watertight enclosures, for a 12 VDC gearmotor, to operate the collection module, and vacuum system, to draw samples into reusable autoclavable tubing and 250-mL bottles. Although designed primarily for water samples, the sampler was easily modified to collect sludge. The sampler held a stable position during deployment, created minimal disturbance in the water column, and was readily cleaned and sanitized for transport. The sampler was field tested initially in a shallow fresh water lake and subsequently in a swine manure treatment lagoon. Analyses of water samples from the lagoon tests showed that chemical and bacterial levels, pH, and EC did not differ between 0.04, 0.47, and 1.0 m depths, but some chemical and bacterial levels differed between winter and spring collections. These results demonstrated the utility of the sampler and suggested that future manure lagoon studies employ fewer or different depths and more sampling dates.
Vroblesky, Don A.; Pravecek, Tasha
2002-01-01
Field comparisons of chemical concentrations obtained from dialysis samplers, passive diffusion bag samplers, and low-flow samplers showed generally close agreement in most of the 13 wells tested during July 2001 at Hickam Air Force Base, Hawaii. The data for chloride, sulfate, iron, alkalinity, arsenic, and methane appear to show that the dialysis samplers are capable of accurately collecting a passive sample for these constituents. In general, the comparisons of volatile organic compound concentrations showed a relatively close correspondence between the two different types of diffusion samples and between the diffusion samples and the low-flow samples collected in most wells. Divergence appears to have resulted primarily from the pumping method, either producing a mixed sample or water not characteristic of aquifer water moving through the borehole under ambient conditions. The fact that alkalinity was not detected in the passive diffusion bag samplers, highly alkaline waters without volatilization loss from effervescence, which can occur when a sample is acidified for preservation. Both dialysis and passive diffusion bag samplers are relatively inexpensive and can be deployed rapidly and easily. Passive diffusion bag samplers are intended for sampling volatile organic compounds only, but dialysis samplers can be used to sample both volatile organic compounds and inorganic solutes. Regenerated cellulose dialysis samplers, however, are subject to biodegradation and probably should be deployed no sooner than 2 weeks prior to recovery. 1 U.S. Geological Survey, Columbia, South Carolina. 2 Air Florce Center for Environmental Excellence, San Antionio, Texas.
Design and validation of a passive deposition sampler.
Einstein, Stephanie A; Yu, Chang-Ho; Mainelis, Gediminas; Chen, Lung Chi; Weisel, Clifford P; Lioy, Paul J
2012-09-01
A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.
Design of dry sand soil stratified sampler
NASA Astrophysics Data System (ADS)
Li, Erkang; Chen, Wei; Feng, Xiao; Liao, Hongbo; Liang, Xiaodong
2018-04-01
This paper presents a design of a stratified sampler for dry sand soil, which can be used for stratified sampling of loose sand under certain conditions. Our group designed the mechanical structure of a portable, single - person, dry sandy soil stratified sampler. We have set up a mathematical model for the sampler. It lays the foundation for further development of design research.
Laboratory evaluation of the CIP 10 personal dust sampler.
Gero, A; Tomb, T
1988-06-01
The "capteur individuel de poussiere" CIP 10 personal dust sampler--developed by the Centre d'Etudes et Recherches de Charbonnages de France (CERCHAR) research organization--is a small, quiet, lightweight unit which samples at a flow rate of 10 L/min. It is a three-stage sampler, using two stages to remove nonrespirable dust particles and one stage to collect the respirable fraction. Airflow through the sampler is induced by the third stage, which is a rotating collector cup that contains a fine grade sponge. Laboratory tests were conducted in a dust chamber using aerosols of Arizona road dust, coal dust and silica dust. Aerosol concentrations measured with the CIP 10 were compared to those measured with the coal mine dust personal sampler unit used in the United States. The results of this study showed that aerosol concentrations measured with the CIP 10 were linearly related to those obtained with the coal mine dust personal sampler. The relationship, however, was dependent on preselector configuration and aerosol characteristics. The collection medium allows some small particles (less than 3 microns) to pass through the sampler without being collected. As much as 13% (by weight) of the aerosol that penetrated through the preseparating stages was exhausted from the sampler.
Huffman, Raegan L.
2002-01-01
Ground-water samples were collected in April 1999 at Naval Air Station Whidbey Island, Washington, with passive diffusion samplers and a submersible pump to compare concentrations of volatile organic compounds (VOCs) in water samples collected using the two sampling methods. Single diffusion samplers were installed in wells with 10-foot screened intervals, and multiple diffusion samplers were installed in wells with 20- to 40-foot screened intervals. The diffusion samplers were recovered after 20 days and the wells were then sampled using a submersible pump. VOC concentrations in the 10-foot screened wells in water samples collected with diffusion samplers closely matched concentrations in samples collected with the submersible pump. Analysis of VOC concentrations in samples collected from the 20- to 40-foot screened wells with multiple diffusion samplers indicated vertical concentration variation within the screened interval, whereas the analysis of VOC concentrations in samples collected with the submersible pump indicated mixing during pumping. The results obtained using the two sampling methods indicate that the samples collected with the diffusion samplers were comparable with and can be considerably less expensive than samples collected using a submersible pump.
NASA Astrophysics Data System (ADS)
Yoneda, J.; Masui, A.; Konno, Y.; Jin, Y.; Kida, M.; Suzuki, K.; Nakatsuka, Y.; Tenma, N.; Nagao, J.
2014-12-01
Natural gas hydrate-bearing pressure core sediments have been sheared in compression using a newly developed Transparent Acrylic Cell Triaxial Testing (TACTT) system to investigate the geophysical and geomechanical behavior of sediments recovered from the deep seabed in the Eastern Nankai Trough, the first Japanese offshore production test region. The sediments were recovered by hybrid pressure core system (hybrid PCS) and pressure cores were cut by pressure core analysis tools (PCATs) on board. These pressure cores were transferred to the AIST Hokkaido centre and trimmed by pressure core non-destructive analysis tools (PNATs) for TACTT system which maintained the pressure and temperature conditions within the hydrate stability boundary, through the entire process of core handling from drilling to the end of laboratory testing. An image processing technique was used to capture the motion of sediment in a transparent acrylic cell, and digital photographs were obtained at every 0.1% of vertical strain during the test. Analysis of the optical images showed that sediments with 63% hydrate saturation exhibited brittle failure, although nonhydrate-bearing sediments exhibited ductile failure. In addition, the increase in shear strength with hydrate saturation increase of natural gas hydrate is in agreement with previous data from synthetic gas hydrate. This research was financially supported by the Research Consortium for Methane Hydrate Resources in Japan (MH21 Research Consortium) that carries out Japan's Methane Hydrate R&D Program by the Ministry of Economy, Trade and Industry (METI).
A wireline piston core barrel for sampling cohesionless sand and gravel below the water table
Zapico, Michael M.; Vales, Samuel; Cherry, John A.
1987-01-01
A coring device has been developed to obtain long and minimally disturbed samples of saturated cohesionless sand and gravel. The coring device, which includes a wireline and piston, was developed specifically for use during hollow-stem auger drilling but it also offers possibilities for cable tool and rotary drilling. The core barrel consists of an inner liner made of inexpensive aluminum or plastic tubing, a piston for core recovery, and an exterior steel housing that protects the liner when the core barrel is driven into the aquifer. The core barrel, which is approximately 1.6m (5.6 feet) long, is advanced ahead of the lead auger by hammering at the surface on drill rods that are attached to the core barrel. After the sampler has been driven 1.5m (5 feet), the drill rods are detached and a wireline is used to hoist the core barrel, with the sample contained in the aluminum or plastic liner, to the surface. A vacuum developed by the piston during the coring operation provides good recovery of both the sediment and aquifer fluids contained in the sediment. In the field the sample tubes can be easily split along their length for on-site inspection or they can be capped with the pore water fluids inside and transported to the laboratory. The cores are 5cm (2 inches) in diameter by 1.5m (5 feet) long. Core acquisition to depths of 35m (115 feet), with a recovery greater than 90 percent, has become routine in University of Waterloo aquifer studies. A large diameter (12.7cm [5 inch]) version has also been used successfully. Nearly continuous sample sequences from sand and gravel aquifers have been obtained for studies of sedimentology, hydraulic conductivity, hydrogeochemistry and microbiology.
Hao, Zhi-Qiang; Cao, Jing-Pei; Zhao, Xiao-Yan; Wu, Yan; Zhu, Jun-Sheng; Dang, Ya-Li; Zhuang, Qi-Qi; Wei, Xian-Yong
2018-03-01
A novel strategy is proposed for the increase of specific surface area (SSA) of porous carbon sphere (PCS) by oxidation and activation. 2-keto-l-gulonic acid mother liquor (GAML) as a high-pollution waste has a relatively high value of reutilization. For its high value-added utilization, GAML is used as the precursor for preparation of PCS as carbon-based electrode materials for electric double-layer capacitor. PCS is prepared by hydrothermal carbonization, carbonization and KOH activation, and Fe(NO 3 ) 3 9H 2 O is used as an oxidizing agent during carbonization. The as-prepared PCS has excellent porosity and high SSA of 2478 m 2 g -1 . Meanwhile, the pore structure of PCS can be controlled by the adjustment of carbonization parameters (carbonization temperature and the loading of Fe(NO 3 ) 3 9H 2 O). Besides, the SSA and specific capacitance of PCS can be increased remarkably when Fe(NO 3 ) 3 9H 2 O is added in carbonization. The specific capacitance of PCS can reach 303.7 F g -1 at 40 mA g -1 . PCSs as electrode material have superior electrochemical stability. After 8000 cycles, the capacitance retention is 98.3% at 2 A g -1 . The electric double-layer capacitance of PCS is improved when CS is carbonized with Fe(NO 3 ) 3 9H 2 O, and the economic and environmental benefits are achieved by the effective recycle of GAML. Copyright © 2017 Elsevier Inc. All rights reserved.
Miller, Thomas R; Elliott, Timothy R; McMaughan, Darcy M; Patnaik, Ashweeta; Naiser, Emily; Dyer, James A; Fournier, Constance J; Hawes, Catherine; Phillips, Charles D
2013-10-01
Medicaid Personal Care Services (PCS) help families meet children's needs for assistance with functional tasks. However, PCS may have other effects on a child's well-being, but research has not yet established the existence of such effects. To investigate the relationship between the number of PCS hours a child receives with subsequent visits to physicians for evaluation and management (E&M) services. Assessment data for 2058 CSHCN receiving PCS were collected in 2008 and 2009. Assessment data were matched with Medicaid claims data for the period of 1 year after the assessment. Zero-inflated negative binomial and generalized linear multivariate regression models were used in the analyses. These models included patient demographics, health status, household resources, and use of other medical services. For every 10 additional PCS hours authorized for a child, the odds of having an E&M physician visit in the next year were reduced by 25%. However, the number of PCS hours did not have a significant effect on the number of visits by those children who did have a subsequent E&M visit. A variety of demographic and health status measures also affect physician use. Medicaid PCS for CSHCN may be associated with reduced physician usage because of benefits realized by continuity of care, the early identification of potential health threats, or family and patient education. PCS services may contribute to a child's well-being by providing continuous relationships with the care team that promote good chronic disease management, education, and support for the family. Copyright © 2013 Elsevier Inc. All rights reserved.
Tunability of soft phononic crystals through large deformation (Conference Presentation)
NASA Astrophysics Data System (ADS)
Bao, Ronghao; Chen, Weiqiu
2017-04-01
Phononic crystals (PCs) have attracted plenty of attention during the past two decades, and a lot of work has been devoted to the numerical, theoretical and experimental analysis of the band gaps of the PCs with 1D, 2D and 3D structures, respectively. The band gaps have been found to be related to the topology of the unit cell, filling ratio, contrast of the material properties between matrix and inclusion, and so on. However, they are fixed when the fabrication of corresponding devices is finished in most cases. Usually, biasing fields (e.g. initial stress, initial deformation, pre-existing electric field, external electric field and magnetic field, etc.) can be utilized to tailor the band gaps in flexible and reconfigurable ways. Recently, the instability-induced deformations triggered by external mechanical loadings have been found to be an effective and reversible way to tune the band gaps and the directionality of PCs made from soft materials, such as silicon and rubber. In this project, a novel design of PCs will be proposed, which consists of perforated plate with some individual beams fixed on the boundary of internal holes. When the external mechanical loading applied on the PCs reaches a threshold value, instability-induced buckling will be triggered and the internal beams might be in contact with each other, which will significantly alter the topology of PCs, and therefore effectively tune the band gaps of PCs. A systematical analysis will be carried out to study the influences on the tunability of PCs with different designs through finite element methods (FEM).
Domínguez-Avila, J Abraham; Wall-Medrano, Abraham; Velderrain-Rodríguez, Gustavo R; Chen, C-Y Oliver; Salazar-López, Norma Julieta; Robles-Sánchez, Maribel; González-Aguilar, Gustavo A
2017-01-25
The positive health effects of phenolic compounds (PCs) have been extensively reported in the literature. An understanding of their bioaccessibility and bioavailability is essential for the elucidation of their health benefits. Before reaching circulation and exerting bioactions in target tissues, numerous interactions take place before and during digestion with either the plant or host's macromolecules that directly impact the organism and modulate their own bioaccessibility and bioavailability. The present work is focused on the gastrointestinal (GI) interactions that are relevant to the absorption and metabolism of PCs and how these interactions impact their pharmacokinetic profiles. Non-digestible cell wall components (fiber) interact intimately with PCs and delay their absorption in the small intestine, instead carrying them to the large intestine. PCs not bound to fiber interact with digestible nutrients in the bolus where they interfere with the digestion and absorption of proteins, carbohydrates, lipids, cholesterol, bile salts and micronutrients through the inhibition of digestive enzymes and enterocyte transporters and the disruption of micelle formation. PCs internalized by enterocytes may reach circulation (through transcellular or paracellular transport), be effluxed back into the lumen (P-glycoprotein, P-gp) or be metabolized by phase I and phase II enzymes. Some PCs can inhibit P-gp or phase I/II enzymes, which can potentially lead to drug-nutrient interactions. The absorption and pharmacokinetic parameters are modified by all of the interactions within the digestive tract and by the presence of other PCs. Undesirable interactions have promoted the development of nanotechnological approaches to promote the bioaccessibility, bioavailability, and bioefficacy of PCs.
Practices of excellent companies in the drug industry.
Pringle, F; Kleiner, B H
1997-01-01
Examines excellence in three major pharmaceutical companies: Merck, Lilly, and Glaxo. Provides an overview of recent trends in the health care industry. Shows that although all three companies are facing tough competition and strict cost-containment pressures, they continue to develop innovative strategies for increasing the quality of their product offering. Analyses Merck's recent acquisition of Medco and its implications; also highlights Merck's "Vital Interests" programme. Discusses Lilly's recent purchase of PCS from McKesson Drug and Lilly's recent efforts to concentrate on its core business. Introduces Helix, Glaxo's new computer network for pharmacists and explains the benefits of this unique service, both to its users and the sponsor.
Shakofsky, S.M.
1995-01-01
In order to assess the effect of filled waste disposal trenches on transport-governing soil properties, comparisons were made between profiles of undisturbed soil and disturbed soil in a simulated waste trench. The changes in soil properties induced by the construction of a simulated waste trench were measured near the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory (INEL) in the semi-arid southeast region of Idaho. The soil samples were collected, using a hydraulically- driven sampler to minimize sample disruption, from both a simulated waste trench and an undisturbed area nearby. Results show that the undisturbed profile has distinct layers whose properties differ significantly, whereas the soil profile in the simulated waste trench is. by comparison, homogeneous. Porosity was increased in the disturbed cores, and, correspondingly, saturated hydraulic conductivities were on average three times higher. With higher soil-moisture contents (greater than 0.32), unsaturated hydraulic conductivities for the undisturbed cores were typically greater than those for the disturbed cores. With lower moisture contents, most of the disturbed cores had greater hydraulic conductivities. The observed differences in hydraulic conductivities are interpreted and discussed as changes in the soil pore geometry.
Zimmerman, Marc J.; Vroblesky, Don A.; Campo, Kimberly W.; Massey, Andrew J.; Scheible, Walter
2005-01-01
Efficient and economical screening methods are needed to detect and to determine the approximate concentrations of potentially toxic trace-element metals in shallow groundwater- discharge areas (pore water) where the metals may pose threats to aquatic organisms; such areas are likely to be near hazardous-waste sites. Pushpoint and nylon-screen diffusion samplers are two complementary options for use in such environments. The pushpoint sampler, a simple well point, is easy to insert manually and to use. Only 1 day is required to collect samples. The nylon-screen diffusion sampler is well suited for use in sediments that do not allow a pump to draw water into a pushpoint sampler. In this study, both types of devices were used in sediments suitable for the use of the pushpoint sampler. Sampling with the nylon-screen diffusion sampler requires at least two site visits: one to deploy the samplers in the sediment, and a second to retrieve the samplers and collect the samples after a predetermined equilibration period. Extensive laboratory quality-control studies, field testing, and laboratory analysis of samples collected at the Nyanza Chemical Waste Dump Superfund site along the Sudbury River in Ashland, Massachusetts, and at a Superfund site-assessment location on Rigby Brook in Clinton, Massachusetts, indicate that these two devices yield comparable results for most metals and should be effective tools for pore-water studies. The nylon-screen diffusion samplers equilibrated within 1-2 days in homogeneous, controlled conditions in the laboratory. Nylon-screen diffusion samplers that were not purged of dissolved oxygen prior to deployment yielded results similar to those that were purged. Further testing of the nylon-screen diffusion samplers in homogeneous media would help to resolve any ambiguities about the data variability from the field studies. Comparison of data from replicate samples taken in both study areas shows that even samples taken from sites within a half-meter radius of one another have distinct differences in pore-water trace-element concentrations. Sequential replicate samples collected with the pushpoint sampler yield consistent results; moving the pushpoint sampler even 5 to 10 centimeters, however, generally produces a second set of data that differs enough from the first set of data to indicate a heterogeneous environment. High concentration biases for barium and zinc in laboratory and field samples collected with nylon-screen diffusion samplers, however, may make their use inappropriate for studies of these metals. Analyzing samples with high iron concentrations required sample dilution by factors of 2 or 10. Because these dilutions caused increases in the reporting levels by the same proportion, a substantial fraction of the data was censored. The results from undiluted samples, however, indicate that both devices should be useful for sampling ground water with metal concentrations close to reporting limits.
47 CFR 20.6 - CMRS spectrum aggregation limit.
Code of Federal Regulations, 2014 CFR
2014-10-01
... the broadband PCS, cellular, or SMR services (including all parties under common control) regulated as... of the population of the PCS licensed service area for the counties contained therein, as determined... covers less than 10 percent of the population of a PCS service area if none of the base stations of the...
47 CFR 20.6 - CMRS spectrum aggregation limit.
Code of Federal Regulations, 2011 CFR
2011-10-01
... the broadband PCS, cellular, or SMR services (including all parties under common control) regulated as... of the population of the PCS licensed service area for the counties contained therein, as determined... covers less than 10 percent of the population of a PCS service area if none of the base stations of the...
Learner-Centred Mathematics and Statistics Education Using Netbook Tablet PCs
ERIC Educational Resources Information Center
Loch, Birgit; Galligan, Linda; Hobohm, Carola; McDonald, Christine
2011-01-01
Tablet technology has been shown to support learner-centred mathematics education when this technology is available to both the lecturer and the students. However, cost is often the barrier to students' use of tablet PCs for their university studies. This article argues that more affordable netbook PCs with tablet capabilities can be viable…
The challenge of mapping between two medical coding systems.
Wojcik, Barbara E; Stein, Catherine R; Devore, Raymond B; Hassell, L Harrison
2006-11-01
Deployable medical systems patient conditions (PCs) designate groups of patients with similar medical conditions and, therefore, similar treatment requirements. PCs are used by the U.S. military to estimate field medical resources needed in combat operations. Information associated with each of the 389 PCs is based on subject matter expert opinion, instead of direct derivation from standard medical codes. Currently, no mechanisms exist to tie current or historical medical data to PCs. Our study objective was to determine whether reliable conversion between PC codes and International Classification of Diseases, 9th Revision, Clinical Modification (ICD-9-CM) diagnosis codes is possible. Data were analyzed for three professional coders assigning all applicable ICD-9-CM diagnosis codes to each PC code. Inter-rater reliability was measured by using Cohen's K statistic and percent agreement. Methods were developed to calculate kappa statistics when multiple responses could be selected from many possible categories. Overall, we found moderate support for the possibility of reliable conversion between PCs and ICD-9-CM diagnoses (mean kappa = 0.61). Current PCs should be modified into a system that is verifiable with real data.
NASA Astrophysics Data System (ADS)
Du, Xiao
2005-02-01
Normal GIGA ETHERNET continuously transmits or receives 8B/10B codes including data codes, idle codes or configuration information. In ETHERNET network, one computer links one port of switch through CAT5 and that is OK. But for EPON, it is different. All ONUs share one fiber in upstream, if we inherit the GIGA ETHERNET PHY, then collision will occur. All ONUs always transmit 8B/10B codes, and the optical signal will overlay. The OLT will receive the fault information. So we need a novel EPON PHY instead of ETHERNET PHY. But its major function is compatible with ETHERNET"s. In this article, first, the function of PCS sub layer is discussed and a novel PCS module is given that can be used in not only EPON system but also in GIGA ETHERNET system. The design of PCS is based on 1000BASE-X PCS technology. And the function of 1000BASE-X PCS should be accomplished first. Next we modify the design in order to meet the requirements of EPON system. In the new design, the auto negotiation and synchronization is the same to the 1000 BASE-X technology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cioffi, L.; Conrad, H.E.
1986-05-01
Tibial chondrocytes were labeled metabolically with /sup 3/H-man and the PCS-H was isolated from the culture medium (CM) and the cell matrix (Ma) pools. Equal amounts of /sup 3/H were incorporated into the PCS-H of the CM and Ma pools. The PCS-H pools were digested with thermolysin, Chondroitinase, and then N-glycanase, and the N-linked oligosaccharides were chromatographed on Con-A Sepharose. The ratios of complex to high mannose oligosaccharides for the CM and Ma were 6.1 and 2.6, respectively. More than 60% of the complex CM N-linked oligosaccharides were charged species whereas only 40% of the Ma N-linked oligosaccharides were charged.more » The oligosaccharides were analyzed by HPLC. Both complex and high mannose oligosaccharides found in the PCS-H of the CM and Ma pools were mixtures of identical structures but the amounts of each structure in the two pools showed marked differences. These observations indicate that distinct PCS-H species are found in the CM and Ma pools.« less
NASA Astrophysics Data System (ADS)
Li, Yichen; Zhou, Lan; Liu, Guojin; Chai, Liqin; Fan, Qinguo; Shao, Jianzhong
2018-06-01
The Silica/Poly(methylmethacrylate-butylacrylate)[SiO2/P(MMA-BA)] photonic crystals(PCs) with brilliant structural colors were fabricated on fabric substrates by co-sedimentation self-assembly, in which the relatively smaller P(MMA-BA) copolymer particles filled in the interstices among the larger SiO2 microspheres. The fabricated composite PCs were mechanically robust and strongly bonded to the substrate because of the cementing effect caused by the soft P(MMA-BA) copolymer particles filling in the interstices of the SiO2 microspheres like cement filling in the gap and tightly holding stones in a sturdy cement wall. The volume fraction and the size ratios of the two components significantly influenced the structural colors of the composite PCs, and the larger volume fraction could improve the structural stability of the composite PCs, while the smaller size ratios could enhance the brightness of the structural colors of the composite PCs. The composite PCs with both high structural stability and brilliant structural colors have great application prospect for structural coloration of textiles.
Dual-Responsive SPMA-Modified Polymer Photonic Crystals and Their Dynamic Display Patterns.
Gao, Zewen; Gao, Dongsheng; Huang, Chao; Zhang, Hanbing; Guo, Jinbao; Wei, Jie
2018-05-28
Light and electrothermal responsive polymer photonic crystals (PCs) modified with 1'-acryloyl chloride-3',3'-dimethyl-6-nitro-spiro(2H-1-benzopyran-2,2'-indoline) (SPMA) are proposed, and their dynamic display patterns are achieved through the combination of the SPMA-modified PCs and a patterned graphite layer. These PCs exhibit fluorescence under UV light irradiation because of the isomerization of the SPMA, which is restricted in the shell of the polymer colloidal spheres. After a voltage is applied to the patterned graphite layer, the fluorescence of PCs in the specific area disappears, and dynamic display patterns are obtained. Under UV light irradiation, the PCs change from the "partial-fluorescence" state to the initial "fluorescence" state, and the patterns disappear. Using this technique, the PC pattern "M L N" on the glass substrate and PC patterns from "0" to "9" on the paper substrate are fabricated. Thus, these dual-responsive PCs have potential applications in information recording, anticounterfeiting, dynamic display, and photoelectric devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Michalka, Samantha W; Kong, Lingqiang; Rosen, Maya L; Shinn-Cunningham, Barbara G; Somers, David C
2015-08-19
The frontal lobes control wide-ranging cognitive functions; however, functional subdivisions of human frontal cortex are only coarsely mapped. Here, functional magnetic resonance imaging reveals two distinct visual-biased attention regions in lateral frontal cortex, superior precentral sulcus (sPCS) and inferior precentral sulcus (iPCS), anatomically interdigitated with two auditory-biased attention regions, transverse gyrus intersecting precentral sulcus (tgPCS) and caudal inferior frontal sulcus (cIFS). Intrinsic functional connectivity analysis demonstrates that sPCS and iPCS fall within a broad visual-attention network, while tgPCS and cIFS fall within a broad auditory-attention network. Interestingly, we observe that spatial and temporal short-term memory (STM), respectively, recruit visual and auditory attention networks in the frontal lobe, independent of sensory modality. These findings not only demonstrate that both sensory modality and information domain influence frontal lobe functional organization, they also demonstrate that spatial processing co-localizes with visual processing and that temporal processing co-localizes with auditory processing in lateral frontal cortex. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Galen, T. J. (Inventor)
1986-01-01
A fluid sampler for collecting a plurality of discrete samples over separate time intervals is described. The sampler comprises a sample assembly having an inlet and a plurality of discreet sample tubes each of which has inlet and outlet sides. A multiport dual acting valve is provided in the sampler in order to sequentially pass air from the sample inlet into the selected sample tubes. The sample tubes extend longitudinally of the housing and are located about the outer periphery thereof so that upon removal of an enclosure cover, they are readily accessible for operation of the sampler in an analysis mode.
Coggins, Marie A; Healy, Catherine B; Lee, Taekhee; Harper, Martin
2014-01-01
Restoration stone work regularly involves work with high-silica-content materials (e.g., sandstone), but low-silica-content materials (<2 % quartz) such as limestone and lime mortar are also used. A combination of short sample duration and low silica content makes the quantification of worker exposure to respirable crystalline silica (RCS) difficult. This problem will be further compounded by the introduction of lower occupational exposure standards for RCS. The objective of this work was to determine whether higher-flow samplers might be an effective tool in characterizing lower RCS concentrations. A short study was performed to evaluate the performance of three high-flow samplers (FSP10, CIP10-R, and GK2.69) using side-by-side sampling with low-flow samplers (SIMPEDS and 10-mm nylon cyclones) for RCS exposure measurement at a restoration stonemasonry field site. A total of 19 side-by-side sample replicates for each high-flow and low-flow sampler pair were collected from work tasks involving limestone and sandstone. Most of the RCS (quartz) masses collected with the high-flow-rate samplers were above the limit of detection (62 % to 84 %) relative to the low-flow-rate samplers (58 % to 78 %). The average of the respirable mass concentration ratios for CIP10-R/SIMPEDS, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs and the range of the quartz concentration ratios for the CIP10-R/SIMPEDS, CIP10-R/10-mm nylon, GK2.69/10-mm nylon, FSP10/SIMPEDS, and FSP10/10-mm nylon pairs included unity with an average close to unity, indicating no likely difference between the reported values for each sampler. Workers reported problems related to the weight of the sampling pumps for the high-flow-rate samplers. Respirable mass concentration data suggest that the high-flow-rate samplers evaluated would be appropriate for sampling respirable dust concentrations during restoration stone work. Results from the comparison of average quartz concentration ratios between high-and low-flow samplers suggest that the higher mass collected by the high-flow-rate samplers did not interfere with the quartz measurement. A sig-nificant portion of the data collected with the high-flow-rate samplers (>82 %) were greater than the limit of detection, which indicates that these samplers are suitable for quantifying exposures, even with low-quartz materials.
Apparatus and techniques for measuring bedload
Hubbell, David Wellington
1964-01-01
The need for accurate determinations of the total sediment discharge of particles of bedload size has prompted this investigation of available and possible measuring apparatus and procedures. The accuracy of measurements of sediment discharge made with trap-type samplers is affected by the variability of sampler efficiency, by the oscillatory variation of bedload discharge, and by sampler placement. Equations that were developed for determining total discharge from measured bedioad discharge and measured suspended-sediment discharge are simplest if the bedload apparatus measures only the true bedload. Early bedload samplers are generally unsatisfactory. Recently developed or suggested apparatus include various improved samplers of the pressure-difference type, a pumping sampler, a magnetic sampler, acoustical instruments that measure the magnitude of the sound of particle collisions, an ultrasonic bedload sampler designed to measure and integrate electronically the concentration and velocity, and a tiltmeter designed to measure the total sediment discharge from the ground tilt that results from the passage of flow. All the pressure-difference samplers are improvements over early samplers, but none are void of the inherent shortcomings of trap-type apparatus; probably the Sphinx (Dutch) and VUV (Hungarian) samplers are the most satisfactory. The acoustical instruments are capable of measuring only the relative discharge. The ultrasonic sampler and the tiltmeter are not adequate without further development. Some new possible apparatus and means for measuring or aiding in measuring bedload discharge are small pit samplers, ultrasonic sounders, pressure transducers, and photography. A small pit sampler for measuring bedload discharge was designed to provide self-placement and portability ; however, its practicability and efficiency are undetermined. Exploratory films show that by using slowmotion photography the discharge of particles larger than about pea size can be determined provided the flow is clear; however, photography generally is not practical. Ultrasonic sounders provide continuous and accurate data on bed configuration and dune movement for use in equations that were developed for computing the bedload discharge. Computations with the equations indicate that the interpretation of the sounding data needs further study. Pressure transducers placed beneath the bed surface possibly can be used to provide information on dune movement; however, their installation would be difficult. The time required for collecting data on bed configuration and dune movement throughout a cross section could be substantially reduced by using several transducers simultaneously in conjunction with an ultrasonic sounder. A modified ultrasonic sounder that provides information on the shape and velocity of large particles and a method for determining the discharge of such particles were proposed; the method seems most feasible for particles of high sphericity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Addleman, Raymond S; Atkinson, David A; Bays, John T
An enhanced swipe sampler and method of making are described. The swipe sampler is made of a fabric containing selected glass, metal oxide, and/or oxide-coated glass or metal fibers. Fibers are modified with silane ligands that are directly attached to the surface of the fibers to functionalize the sampling surface of the fabric. The swipe sampler collects various target analytes including explosives and other threat agents on the surface of the sampler.
Individual Passive Chemical Sampler Testing Continued Chemical Agent and TIC Performance Validation
2002-04-01
period of high temperature, although the atmosphere was wet. 4.3 Post-Deployment Activities The deployment of the samplers did not go as...4.4 Day 0 Adsorption and Recovery Comparison Between Gore Low-Level and Gore High -Level Samplers at Varying Temperatures...43 Figure 4.5 Day 0 Adsorption and Recovery Comparison Between SKC High Level and Gore High -Level Samplers
Chen, Wen; Hambleton, Sarah; Seifert, Keith A; Carisse, Odile; Diarra, Moussa S; Peters, Rick D; Lowe, Christine; Chapados, Julie T; Lévesque, C André
2018-05-01
Spore samplers are widely used in pathogen surveillance but not so much for monitoring the composition of aeromycobiota. In Canada, a nationwide spore-sampling network (AeroNet) was established as a pilot project to assess fungal community composition in air and rain samples collected using three different spore samplers in the summers of 2010 and 2011. Metabarcodes of the internal transcribed spacer (ITS) were exhaustively characterized for three of the network sites, in British Columbia (BC), Québec (QC), and Prince Edward Island (PEI), to compare performance of the samplers. Sampler type accounted for ca. 20% of the total explainable variance in aeromycobiota compositional heterogeneity, with air samplers recovering more Ascomycota and rain samplers recovering more Basidiomycota. Spore samplers showed different abilities to collect 27 fungal genera that are plant pathogens. For instance, Cladosporium spp., Drechslera spp., and Entyloma spp. were collected mainly by air samplers, while Fusarium spp., Microdochium spp., and Ustilago spp. were recovered more frequently with rain samplers. The diversity and abundance of some fungi were significantly affected by sampling location and time (e.g., Alternaria and Bipolaris ) and weather conditions (e.g., Mycocentrospora and Leptosphaeria ), and depended on using ITS1 or ITS2 as the barcoding region (e.g., Epicoccum and Botrytis ). The observation that Canada's aeromycobiota diversity correlates with cooler, wetter conditions and northward wind requires support from more long-term data sets. Our vision of the AeroNet network, combined with high-throughput sequencing (HTS) and well-designed sampling strategies, may contribute significantly to a national biovigilance network for protecting plants of agricultural and economic importance in Canada. IMPORTANCE The current study compared the performance of spore samplers for collecting broad-spectrum air- and rain-borne fungal pathogens using a metabarcoding approach. The results provided a thorough characterization of the aeromycobiota in the coastal regions of Canada in relation to the influence of climatic factors. This study lays the methodological basis to eventually develop knowledge-based guidance on pest surveillance by assisting in the selection of appropriate spore samplers. © Crown copyright 2018.
Enabling co-simulation of tokamak plant models and plasma control systems
Walker, M. L.
2017-12-22
A system for connecting the Plasma Control System and a model of the tokamak Plant in closed loop co-simulation for plasma control development has been in routine use at DIII-D for more than 20 years and at other fusion labs that use variants of the DIII-D PCS for approximately the last decade. Here, co-simulation refers to the simultaneous execution of two independent codes with the exchange of data - Plant actuator commands and tokamak diagnostic data - between them during execution. Interest in this type of PCS-Plant simulation technology has also been growing recently at other fusion facilities. In fact,more » use of such closed loop control simulations is assumed to play an even larger role in the development of both the ITER Plasma Control System (PCS) and the experimental operation of the ITER device, where they will be used to support verification/validation of the PCS and also for ITER pulse schedule development and validation. We describe the key use cases that motivate the co-simulation capability and the features that must be provided by the Plasma Control System to support it. These features could be provided by the PCS itself or by a model of the PCS. If the PCS itself is chosen to provide them, there are requirements imposed on its architecture. If a PCS model is chosen, there are requirements imposed on the initial implementation of this simulation as well as long-term consequences for its continued development and maintenance. We describe these issues for each use case and discuss the relative merits of the two choices. Several examples are given illustrating uses of the co-simulation method to address problems of plasma control during the operation of DIII-D and of other devices that use the DIII-D PCS.« less
Enabling co-simulation of tokamak plant models and plasma control systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, M. L.
A system for connecting the Plasma Control System and a model of the tokamak Plant in closed loop co-simulation for plasma control development has been in routine use at DIII-D for more than 20 years and at other fusion labs that use variants of the DIII-D PCS for approximately the last decade. Here, co-simulation refers to the simultaneous execution of two independent codes with the exchange of data - Plant actuator commands and tokamak diagnostic data - between them during execution. Interest in this type of PCS-Plant simulation technology has also been growing recently at other fusion facilities. In fact,more » use of such closed loop control simulations is assumed to play an even larger role in the development of both the ITER Plasma Control System (PCS) and the experimental operation of the ITER device, where they will be used to support verification/validation of the PCS and also for ITER pulse schedule development and validation. We describe the key use cases that motivate the co-simulation capability and the features that must be provided by the Plasma Control System to support it. These features could be provided by the PCS itself or by a model of the PCS. If the PCS itself is chosen to provide them, there are requirements imposed on its architecture. If a PCS model is chosen, there are requirements imposed on the initial implementation of this simulation as well as long-term consequences for its continued development and maintenance. We describe these issues for each use case and discuss the relative merits of the two choices. Several examples are given illustrating uses of the co-simulation method to address problems of plasma control during the operation of DIII-D and of other devices that use the DIII-D PCS.« less
Dynamic NMDAR-mediated properties of place cells during the object place memory task.
Faust, Thomas W; Robbiati, Sergio; Huerta, Tomás S; Huerta, Patricio T
2013-01-01
N-methyl-D-aspartate receptors (NMDAR) in the hippocampus participate in encoding and recalling the location of objects in the environment, but the ensemble mechanisms by which NMDARs mediate these processes have not been completely elucidated. To address this issue, we examined the firing patterns of place cells in the dorsal CA1 area of the hippocampus of mice (n = 7) that performed an object place memory (OPM) task, consisting of familiarization (T1), sample (T2), and choice (T3) trials, after systemic injection of 3-[(±)2-carboxypiperazin-4yl]propyl-1-phosphate (CPP), a specific NMDAR antagonist. Place cell properties under CPP (CPP-PCs) were compared to those after control saline injection (SAL-PCs) in the same mice. We analyzed place cells across the OPM task to determine whether they signaled the introduction or movement of objects by NMDAR-mediated changes of their spatial coding. On T2, when two objects were first introduced to a familiar chamber, CPP-PCs and SAL-PCs showed stable, vanishing or moving place fields in addition to changes in spatial information (SI). These metrics were comparable between groups. Remarkably, previously inactive CPP-PCs (with place fields emerging de novo on T2) had significantly weaker SI increases than SAL-PCs. On T3, when one object was moved, CPP-PCs showed reduced center-of-mass (COM) shift of their place fields. Indeed, a subset of SAL-PCs with large COM shifts (>7 cm) was largely absent in the CPP condition. Notably, for SAL-PCs that exhibited COM shifts, those initially close to the moving object followed the trajectory of the object, whereas those far from the object did the opposite. Our results strongly suggest that the SI changes and COM shifts of place fields that occur during the OPM task reflect key dynamic properties that are mediated by NMDARs and might be responsible for binding object identity with location.
Dynamic NMDAR-mediated properties of place cells during the object place memory task
Faust, Thomas W.; Robbiati, Sergio; Huerta, Tomás S.; Huerta, Patricio T.
2013-01-01
N-methyl-D-aspartate receptors (NMDAR) in the hippocampus participate in encoding and recalling the location of objects in the environment, but the ensemble mechanisms by which NMDARs mediate these processes have not been completely elucidated. To address this issue, we examined the firing patterns of place cells in the dorsal CA1 area of the hippocampus of mice (n = 7) that performed an object place memory (OPM) task, consisting of familiarization (T1), sample (T2), and choice (T3) trials, after systemic injection of 3-[(±)2-carboxypiperazin-4yl]propyl-1-phosphate (CPP), a specific NMDAR antagonist. Place cell properties under CPP (CPP–PCs) were compared to those after control saline injection (SAL–PCs) in the same mice. We analyzed place cells across the OPM task to determine whether they signaled the introduction or movement of objects by NMDAR-mediated changes of their spatial coding. On T2, when two objects were first introduced to a familiar chamber, CPP–PCs and SAL–PCs showed stable, vanishing or moving place fields in addition to changes in spatial information (SI). These metrics were comparable between groups. Remarkably, previously inactive CPP–PCs (with place fields emerging de novo on T2) had significantly weaker SI increases than SAL–PCs. On T3, when one object was moved, CPP–PCs showed reduced center-of-mass (COM) shift of their place fields. Indeed, a subset of SAL–PCs with large COM shifts (>7 cm) was largely absent in the CPP condition. Notably, for SAL–PCs that exhibited COM shifts, those initially close to the moving object followed the trajectory of the object, whereas those far from the object did the opposite. Our results strongly suggest that the SI changes and COM shifts of place fields that occur during the OPM task reflect key dynamic properties that are mediated by NMDARs and might be responsible for binding object identity with location. PMID:24381547
Lee, R; Skinner, A; Bornstein, M H; Radford, A N; Campbell, A; Graham, K; Pearson, R M
2017-05-01
To explore the utility of first-person viewpoint cameras at home, for recording mother and infant behaviour, and for reducing problems associated with participant reactivity, which represent a fundamental bias in observational research. We compared footage recording the same play interactions from a traditional third-person point of view (3rd PC) and using cameras worn on headbands (first-person cameras [1st PCs]) to record first-person points of view of mother and infant simultaneously. In addition, we left the dyads alone with the 1st PCs for a number of days to record natural mother-child behaviour at home. Fifteen mothers with infants (3-12 months of age) provided a total of 14h of footage at home alone with the 1st PCs. Codings of maternal behaviour from footage of the same scenario captured from 1st PCs and 3rd PCs showed high concordance (kappa >0.8). Footage captured by the 1st PCs also showed strong inter-rater reliability (kappa=0.9). Data from 1st PCs during sessions recorded alone at home captured more 'negative' maternal behaviours per min than observations using 1st PCs whilst a researcher was present (mean difference=0.90 (95% CI 0.5-1.2, p<0.001 representing 1.5 SDs). 1st PCs offer a number of practical advantages and can reliably record maternal and infant behaviour. This approach can also record a higher frequency of less socially desirable maternal behaviours. It is unclear whether this difference is due to lack of need of the presence of researcher or the increased duration of recordings. This finding is potentially important for research questions aiming to capture more ecologically valid behaviours and reduce demand characteristics. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Performance of Prototype High-Flow Inhalable Dust Sampler in a Livestock Production Facility
Anthony, T. Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John
2017-01-01
A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24-hours on 19 days over a three-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p=0.16; mean difference 0.03 mg/m3). Forty-four paired samples were available for endotoxin analysis, and a significant (p=0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype’s disposable thin-film polycarbonate capsule was included with the filter in the 1-hour extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m3 gravimetric, 2328 EU/m3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise specified (PNOS) limits of 10 mg/m3, including using the prototype as a personal sampler. PMID:27792469
Performance of prototype high-flow inhalable dust sampler in a livestock production facility.
Anthony, T Renée; Cai, Changjie; Mehaffy, John; Sleeth, Darrah; Volckens, John
2017-05-01
A high-flow inhalable sampler, designed for operational flow rates up to 10 L/min using computer simulations and examined in wind tunnel experiments, was evaluated in the field. This prototype sampler was deployed in collocation with an IOM (the benchmark standard sampler) in a swine farrowing building to examine the sampling performance for assessing concentrations of inhalable particulate mass and endotoxin. Paired samplers were deployed for 24 hr on 19 days over a 3-month period. On each sampling day, the paired samplers were deployed at three fixed locations and data were analyzed to identify agreement and to examine systematic biases between concentrations measured by these samplers. Thirty-six paired gravimetric samples were analyzed; insignificant, unsubstantial differences between concentrations were identified between the two samplers (p = 0.16; mean difference 0.03 mg/m 3 ). Forty-four paired samples were available for endotoxin analysis, and a significant (p = 0.001) difference in endotoxin concentration was identified: the prototype sampler, on average, had 120 EU/m 3 more endotoxin than did the IOM samples. Since the same gravimetric samples were analyzed for endotoxin content, the endotoxin difference is likely attributable to differences in endotoxin extraction. The prototype's disposable thin-film polycarbonate capsule was included with the filter in the 1-hr extraction procedure while the internal plastic cassette of the IOM required a rinse procedure that is susceptible to dust losses. Endotoxin concentrations measured with standard plastic IOM inserts that follow this rinsing procedure may underestimate the true endotoxin exposure concentrations. The maximum concentrations in the study (1.55 mg/m 3 gravimetric, 2328 EU/m 3 endotoxin) were lower than other agricultural or industrial environments. Future work should explore the performance of the prototype sampler in dustier environments, where concentrations approach particulates not otherwise specified (PNOS) limits of 10 mg/m 3 , including using the prototype as a personal sampler.
NASA Astrophysics Data System (ADS)
Masey, Nicola; Gillespie, Jonathan; Heal, Mathew R.; Hamilton, Scott; Beverland, Iain J.
2017-07-01
We assessed the precision and accuracy of nitrogen dioxide (NO2) concentrations over 2-day, 3-day and 7-day exposure periods measured with the following types of passive diffusion samplers: standard (open) Palmes tubes; standard Ogawa samplers with commercially-prepared Ogawa absorbent pads (Ogawa[S]); and modified Ogawa samplers with absorbent-impregnated stainless steel meshes normally used in Palmes tubes (Ogawa[P]). We deployed these passive samplers close to the inlet of a chemiluminescence NO2 analyser at an urban background site in Glasgow, UK over 32 discrete measurement periods. Duplicate relative standard deviation was <7% for all passive samplers. The Ogawa[P], Ogawa[S] and Palmes samplers explained 93%, 87% and 58% of temporal variation in analyser concentrations respectively. Uptake rates for Palmes and Ogawa[S] samplers were positively and linearly associated with wind-speed (P < 0.01 and P < 0.05 respectively). Computation of adjusted uptake rates using average wind-speed observed during each sampling period increased the variation in analyser concentrations explained by Palmes and Ogawa[S] estimates to 90% and 92% respectively, suggesting that measurements can be corrected for shortening of diffusion path lengths due to wind-speed to improve the accuracy of estimates of short-term NO2 exposure. Monitoring situations where it is difficult to reliably estimate wind-speed variations, e.g. across multiple sites with different unknown exposures to local winds, and personal exposure monitoring, are likely to benefit from protection of these sampling devices from the effects of wind, for example by use of a mesh or membrane across the open end. The uptake rate of Ogawa[P] samplers was not associated with wind-speed resulting in a high correlation between estimated concentrations and observed analyser concentrations. The use of Palmes meshes in Ogawa[P] samplers reduced the cost of sampler preparation and removed uncertainty associated with the unknown manufacturing process for the commercially-prepared collection pads.
Tile-based Level of Detail for the Parallel Age
DOE Office of Scientific and Technical Information (OSTI.GOV)
Niski, K; Cohen, J D
Today's PCs incorporate multiple CPUs and GPUs and are easily arranged in clusters for high-performance, interactive graphics. We present an approach based on hierarchical, screen-space tiles to parallelizing rendering with level of detail. Adapt tiles, render tiles, and machine tiles are associated with CPUs, GPUs, and PCs, respectively, to efficiently parallelize the workload with good resource utilization. Adaptive tile sizes provide load balancing while our level of detail system allows total and independent management of the load on CPUs and GPUs. We demonstrate our approach on parallel configurations consisting of both single PCs and a cluster of PCs.
Field intercomparison of ammonia passive samplers: results and lessons learned.
NASA Astrophysics Data System (ADS)
Stephens, Amy; Leeson, Sarah; Jones, Matthew; van Dijk, Netty; Kentisbeer, John; Twigg, Marsailidh; Simmons, Ivan; Braban, Christine; Martin, Nick; Poskitt, Janet; Ferm, Martin; Seitler, Eva; Sacco, Paolo; Gates, Linda; Stolk, Ariën; Stoll, Jean-Marc; Tang, Sim
2017-04-01
Ammonia pollution contributes significantly to eutrophication and acidification of ecosystems with resultant losses of biodiversity and ecosystem changes. Monitoring of ambient ammonia over a wide spatial and long temporal scales is primarily done with low-cost diffusive samplers. Less frequently, surface flux measurements of ammonia can be made using passive samplers at plot scale. This paper will present a field intercomparison conducted within the MetNH3 project to assess the performance of passive samplers for ambient measurements of ammonia. Eight different designs of commercial passive samplers housed in shelters provided by the manufacturer/laboratory were exposed over an 8-week period at the Whim experimental field site in Scotland between August and October 2016. Whim Bog has a facility in place for controlled releases of ammonia (http://www.whimbog.ceh.ac.uk/). Automated conditional release from the line source occurs when the wind direction in the preceding minute is from the northeast (wind sector 180-215°) and wind speed is > 5 m s-1. The passive samplers were exposed at different distances from the release source (16, 32 and 60 m) and also at a background location. Most were exposed for 2 x 4-week long periods and some for 4 x 2-week long periods. At the 32 m position, an active denuder method, the CEH DELTA sampler and a continuous high temporal resolution wet chemistry ammonia instrument (AiRRmonia, Mechatronics, NL.) were also deployed alongside the passive samplers to provide reference measurements of ammonia. Results are presented within the context of the MetNH3 CATFAC controlled laboratory exposure assessments. The results are discussed in terms of typical deployments of passive samplers and quality control. Measurement for policy evidence for both local and regional studies using passive samplers are discussed.
Jeong, Yoonah; Schäffer, Andreas; Smith, Kilian
2018-06-15
In this work, Oasis HLB® beads were embedded in a silicone matrix to make a single phase passive sampler with a higher affinity for polar and ionisable compounds than silicone alone. The applicability of this mixed polymer sampler (MPS) was investigated for 34 aquatic contaminants (log K OW -0.03 to 6.26) in batch experiments. The influence of flow was investigated by comparing uptake under static and stirred conditions. The sampler characteristics of the MPS was assessed in terms of sampling rates (R S ) and sampler-water partition coefficients (K SW ), and these were compared to those of the polar organic chemical integrative sampler (POCIS) as a reference kinetic passive sampler. The MPS was characterized as an equilibrium sampler for both polar and non-polar compounds, with faster uptake rates and a shorter time to reach equilibrium than the POCIS. Water flow rate impacted sampling rates by up to a factor of 12 when comparing static and stirred conditions. In addition, the relative accumulation of compounds in the polyethersulfone (PES) membranes versus the inner Oasis HLB sorbent was compared for the POCIS, and ranged from <1% to 83% depending on the analyte properties. This is indicative of a potentially significant lag-phase for less polar compounds within POCIS. The findings of this study can be used to quantitatively describe the partitioning and kinetic behaviour of MPS and POCIS for a range of aquatic organic contaminants for application in field sampling. Copyright © 2018 Elsevier B.V. All rights reserved.
Noninvasive pH monitoring of platelet concentrates: a large field test.
Gkoumassi, Effimia; Klein-Bosgoed, Christa; Dijkstra-Tiekstra, Margriet J; de Korte, Dirk; de Wildt-Eggen, Janny
2013-10-01
Developing new quality control methods for platelet concentrates (PCs) can contribute to increasing transfusion safety and efficiency. The aim of this study was to investigate in a large field test the quality of expired PCs and whether 100% noninvasive pH monitoring can be used to predict PC quality. The pH of 13,693 PCs produced for transfusion was monitored daily using Blood Storage, Inc.'s pH sterile, automated fluoroscopic evaluation technology. Upon indication of compromised quality or expiration, PCs were returned and in vitro tests were performed. A total of 998 PCs were returned, of which 962 outdated, 26 had a positive BacT/ALERT reaction, seven had aggregates, one was without swirl, one had low pH, and one had high pH. BacT/ALERT was faster in identifying bacterial contamination than pH measurements. The pH at the end of the storage period was significantly lower than at the beginning. In vitro tests indicated that while the PC quality was acceptable upon expiration, it rapidly declined after expiration. In this setting where the vast majority of PCs were of good quality and within acceptable pH limits, daily, noninvasive routine pH measurement has limited added value in identifying quality-compromised PCs. © 2013 Sanquin Research. Transfusion © 2013 American Association of Blood Banks.
Lefante, John J; Harmon, Gary N; Ashby, Keith M; Barnard, David; Webber, Larry S
2005-04-01
The utility of the SF-8 for assessing health-related quality of life (HRQL) is demonstrated. Race and gender differences in physical component (PCS) and mental component (MCS) summary scores among participants in the CENLA Medication Access Program (CMAP), along with comparisons to the United States population are made. Age-adjusted multiple linear regression analyses were used to compare 1687 CMAP participants to the US population. Internal race and gender comparisons, adjusting for age and the number of self reported diagnoses, were also obtained. The paired t-test was used to assess 6-month change in PCS and MCS scores for a subset of 342 participants. CMAP participants have PCS and MCS scores that are significantly 10-12 points lower than the US population, indicating lower self-reported HRQL. Females have significantly higher PCS and significantly lower MCS than males. African-Americans have significantly higher MCS than Caucasians. Significant increases in both PCS and MCS were observed for the subset of participants after 6 months of intervention. The expected lower baseline PCS and MCS measures and the expected associations with age and number of diagnoses indicate that the SF-8 survey is an effective tool for measuring the HRQL of participants in this program. Preliminary results indicate significant increases in both PCS and MCS 6 months after intervention.
The production of p-cresol sulfate and indoxyl sulfate in vegetarians versus omnivores.
Patel, Kajal P; Luo, Frank J-G; Plummer, Natalie S; Hostetter, Thomas H; Meyer, Timothy W
2012-06-01
The uremic solutes p-cresol sulfate (PCS) and indoxyl sulfate (IS) are generated by colon bacteria acting on food components that escape absorption in the small bowel. The production of these potentially toxic compounds may thus be influenced by diet. This study examined whether production of PCS and IS is different in vegetarians and omnivores. The production of PCS and IS was assessed by measuring their urinary excretion rates in participants with normal kidney function. Studies were carried out in 15 vegetarians and 11 individuals consuming an unrestricted diet. Participants recorded food intake over 4 days and collected urine over the final 2 days of each of two study periods, which were 1 month apart. Average PCS excretion was 62% lower (95% confidence interval [95% CI], 15-83) and average IS excretion was 58% lower (95% CI, 39-71) in vegetarians than in participants consuming an unrestricted diet. Food records revealed that lower excretion of PCS and IS in vegetarians was associated with a 69% higher (95% CI, 20-139) fiber intake and a 25% lower (95% CI, 3-42) protein intake. PCS and IS excretion rates varied widely among individual participants and were not closely correlated with each other but tended to remain stable in individual participants over 1 month. PCS and IS production rates are markedly lower in vegetarians than in individuals consuming an unrestricted diet.
Three-Dimensional Self-Assembled Photonic Crystal Waveguide
NASA Astrophysics Data System (ADS)
Baek, Kang-Hyun
Photonic crystals (PCs), two- or three-dimensionally periodic, artificial, and dielectric structures, have a specific forbidden band for electromagnetic waves, referred to as photonic bandgap (PBG). The PBG is analogous to the electronic bandgap in natural crystal structures with periodic atomic arrangement. A well-defined and embedded planar, line, or point defect within the PCs causes a break in its structural periodicity, and introduces a state in the PBG for light localization. It offers various applications in integrated optics and photonics including optical filters, sharp bending light guides and very low threshold lasers. Using nanofabrication processes, PCs of the 2-D slab-type and 3-D layer-by-layer structures have been investigated widely. Alternatively, simple and low-cost self-assembled PCs with full 3-D PBG, inverse opals, have been suggested. A template with face centered cubic closed packed structure, opal, may initially be built by self-assembly of colloidal spheres, and is selectively removed after infiltrating high refractive index materials into the interstitials of spheres. In this dissertation, the optical waveguides utilizing the 3-D self-assembled PCs are discussed. The waveguides were fabricated by microfabrication technology. For high-quality colloidal silica spheres and PCs, reliable synthesis, self-assembly, and characterization techniques were developed. Its theoretical and experimental demonstrations are provided and correlated. They suggest that the self-assembled PCs with PBG are feasible for the applications in integrated optics and photonics.
Breault, Robert F.; Cooke, Matthew G.; Merrill, Michael
2004-01-01
The U.S. Geological Survey, in cooperation with the Massachusetts Executive Office of Environmental Affairs Department of Fish and Game Riverways Program, and the U.S. Environmental Protection Agency, studied sediment and water quality in the lower Neponset River, which is a tributary to Boston Harbor. Grab and core samples of sediment were tested for elements and organic compounds including polyaromatic hydrocarbons, organochlorine pesticides, and polychlorinated biphenyls. Physical properties of sediment samples, including grain size, were also measured. Selected sediment-core samples were tested for reactive sulfides and metals by means of the toxicity characteristic leaching procedure, which are sediment-disposal-related tests. Water quality, with respect to polychlorinated biphenyl contamination, was determined by testing samples collected by PISCES passive-water-column samplers for polychlorinated biphenyl congeners. Total concentrations of polychlorinated biphenyls were calculated by congener and by Aroclor.
Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler.
Stewart, Justin; Sleeth, Darrah K; Handy, Rod G; Pahler, Leon F; Anthony, T Renee; Volckens, John
2017-03-01
A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler's performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times.
High speed sampler and demultiplexer
McEwan, Thomas E.
1995-01-01
A high speed sampling demultiplexer based on a plurality of sampler banks, each bank comprising a sample transmission line for transmitting an input signal, a strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates at respective positions along the sample transmission line for sampling the input signal in response to the strobe signal. Strobe control circuitry is coupled to the plurality of banks, and supplies a sequence of bank strobe signals to the strobe transmission lines in each of the plurality of banks, and includes circuits for controlling the timing of the bank strobe signals among the banks of samplers. Input circuitry is included for supplying the input signal to be sampled to the plurality of sample transmission lines in the respective banks. The strobe control circuitry can repetitively strobe the plurality of banks of samplers such that the banks of samplers are cycled to create a long sample length. Second tier demultiplexing circuitry is coupled to each of the samplers in the plurality of banks. The second tier demultiplexing circuitry senses the sample taken by the corresponding sampler each time the bank in which the sampler is found is strobed. A plurality of such samples can be stored by the second tier demultiplexing circuitry for later processing. Repetitive sampling with the high speed transient sampler induces an effect known as "strobe kickout". The sample transmission lines include structures which reduce strobe kickout to acceptable levels, generally 60 dB below the signal, by absorbing the kickout pulses before the next sampling repetition.
WHATS-3: An improved flow-through multi-bottle fluid sampler for deep-sea geofluid research
NASA Astrophysics Data System (ADS)
Miyazaki, Junichi; Makabe, Akiko; Matsui, Yohei; Ebina, Naoya; Tsutsumi, Saki; Ishibashi, Jun-ichiro; Chen, Chong; Kaneko, Sho; Takai, Ken; Kawagucci, Shinsuke
2017-06-01
Deep-sea geofluid systems, such as hydrothermal vents and cold seeps, are key to understanding subseafloor environments of Earth. Fluid chemistry, especially, provides crucial information towards elucidating the physical, chemical and biological processes that occur in these ecosystems. To accurately assess fluid and gas properties of deep-sea geofluids, well-designed pressure-tight fluid samplers are indispensable and as such they are important assets of deep-sea geofluid research. Here, the development of a new flow-through, pressure-tight fluid sampler capable of four independent sampling events (two subsamples for liquid and gas analyses from each) is reported. This new sampler, named WHATS-3, is a new addition to the WHATS-series samplers and a major upgrade from the previous WHATS-2 sampler with improvements in sample number, valve operational time, physical robustness, and ease of maintenance. Routine laboratory-based pressure tests proved that it is suitable for operation up to 35 MPa pressure. Successful field tests of the new sampler were also carried out in five hydrothermal fields, two in Indian Ocean and three in Okinawa Trough (max. depth 3,300 m). Relations of Mg and major ion species demonstrated bimodal mixing trends between a hydrothermal fluid and seawater, confirming the high-quality of fluids sampled. The newly developed WHATS-3 sampler is well-balanced in sampling capability, field usability, and maintenance feasibility, and can serve as one of the best geofluid samplers available at present to conduct efficient research of deep-sea geofluid systems.
Hazrati, Sadegh; Harrad, Stuart
2007-03-01
PUF disk passive air samplers are increasingly employed for monitoring of POPs in ambient air. In order to utilize them as quantitative sampling devices, a calibration experiment was conducted. Time integrated indoor air concentrations of PCBs and PBDEs were obtained from a low volume air sampler operated over a 50 d period alongside the PUF disk samplers in the same office microenvironment. Passive sampling rates for the fully-sheltered sampler design employed in our research were determined for the 51 PCB and 7 PBDE congeners detected in all calibration samples. These values varied from 0.57 to 1.55 m3 d(-1) for individual PCBs and from 1.1 to 1.9 m3 d(-1) for PBDEs. These values are appreciably lower than those reported elsewhere for different PUF disk sampler designs (e.g. partially sheltered) employed under different conditions (e.g. in outdoor air), and derived using different calibration experiment configurations. This suggests that sampling rates derived for a specific sampler configuration deployed under specific environmental conditions, should not be extrapolated to different sampler configurations. Furthermore, our observation of variable congener-specific sampling rates (consistent with other studies), implies that more research is required in order to understand fully the factors that influence sampling rates. Analysis of wipe samples taken from the inside of the sampler housing, revealed evidence that the housing surface scavenges particle bound PBDEs.
Passive sampler for dissolved organic matter in freshwater environments.
Lam, Buuan; Simpson, André J
2006-12-15
A passive sampler for the isolation of dissolved organic matter (DOM) from freshwater environments is described. The sampler consists of a molecular weight selective membrane (1000 kDa) and an anion exchange resin (diethylaminoethylcellulose (DEAE-cellulose)). NMR indicates the samplers isolate DOM that is nearly indistinguishable from that isolated using the batch DEAE-cellulose procedure. In a comparative study DOM isolated from Lake Ontario cost approximately 0.30 dollars/mg to isolate using the passive samplers while DOM isolated using the traditional batch procedure cost approximately 8-10 dollars/mg. The samplers have been shown to be effective in a range of freshwater environments including a large inland lake (Lake Ontario), fast flowing tributary, and wetland. Large amounts (gram quantities of DOM) can be easily isolated by increasing the size or number of samplers deployed. Samplers are easy to construct, negate the need for pressure filtering, and also permit a range of temporal and spatial experiments that would be very difficult or impossible to perform using conventional approaches. For example, DOM can be monitored on a regular basis at numerous different locations, or samplers could be set at different depths in large lakes. Furthermore, they could potentially be deployed into hard to reach environments such as wells, groundwater aquifers, etc., and as they are easy to use, they can be mailed to colleagues or included with expeditions going to difficult to reach places such as the Arctic and Antarctic.
Portable Chemical Sterilizer (PCS) for Surgical Instruments
2004-12-01
PORTABLE CHEMICAL STERILIZER (PCS) FOR SURGICAL INSTRUMENTS CJ Doona*, FE Feeherry, MA Curtin‡, K Kustin‡, S Kandlikar‡ U.S. Army-Soldier...denotes Contractors) Biomedical Technologies ABSTRACT A novel device called the Portable Chemical Sterilizer (PCS) has been developed for the...rapid, safe, portable, power-free, and convenient sterilization of objects or surfaces contaminated with pathogenic microorganisms that cause
Using Tablet PCs in the Classroom: An Investigation of Students' Expectations and Reactions
ERIC Educational Resources Information Center
Bonds-Raacke, Jennifer M.; Raacke, John D.
2008-01-01
The purposes of the current experiments were to investigate: (a) students' expectations with regard to the use of Tablet PCs within the classroom, (b) students' attitudes toward the implementation of Tablet PCs within the classroom, and (c) the resulting classroom environment from the use of various technologies. Results indicated that although…
Scaffolding Equals Success in Teaching Tablet PCs
ERIC Educational Resources Information Center
Dickerson, Jeremy; Williams, Scott; Browning, J. B.
2009-01-01
After many years of using the mouse and keyboard as the primary means of computer input, people are seeing a strong surge into a new generation of input technologies such as tablet PCs. As more professionals adopt tablet PCs for use in the workplace, there is a subsequent increased demand for tablet PC instruction in the classroom. Examples of…
Tablet PCs in Engineering Mathematics Courses at the J.B. Speed School of Engineering
ERIC Educational Resources Information Center
Hieb, Jeffrey L.; Ralston, Patricia A. S.
2010-01-01
In fall 2007, J.B. Speed School of Engineering at the University of Louisville joined the ranks of universities requiring the purchase of Tablet PCs for all new entering students. This article presents a description of how the Department of Engineering Fundamentals incorporated Tablet PCs into their instruction, a review of the literature…
Tablet PCs: The Write Approach
ERIC Educational Resources Information Center
Milner, Jacob
2006-01-01
This article discusses the transforming effects of tablet PCs in the classroom. As 1-to-1 computing becomes the goal on K-12 campuses, school districts are turning to this newer, pen-based technology. Saint Mary's School's new Lenovo ThinkPad X41 tablet PCs had transformed the way Saint Mary's teachers did their jobs. Teachers created outlines for…
Łukaszuk, Cecylia; Krajewska-Kułak, Elżbieta; Guzowski, Andrzej; Kułak, Wojciech; Kraszyńska, Bogumiła
2017-07-20
Although several air sampling devices for identifying and enumerating airborne microorganisms are commercially available, each poses some limitations. The aim of this study was to evaluate air pollution fungi using three such samplers: SAS Super 100, Microbiological Air Sampler (MAS) 100, and Air IDEAL. Mycological air was taken from the cellars of a 17th-century church in Siemiatycze, Poland, and the nearby outdoor environment. With samplers placed 1.5 m above the floor, microbial flora in air samples collected inside and outside the cellar were detected. The number of colony-forming units (CFU) of fungi obtained with the three samplers from the cellars and outdoor environment differed; the most CFU were obtained with the Air IDEAL and the least with the SAS Super 100. Significant differences emerged in CFUs collected from air samples with the MAS 100 and SAS Super 100, on the one hand, and the SAS Super 100 and Air IDEAL, on the other. Otherwise, results among the samplers were different. More Cladosporium species were collected with the MAS 100 sampler, whereas more Fusarium and Aspergillus species were collected with the Air IDEAL sampler. Significant differences among CFU/m³ values among the tested sites depended on the sampler used.
Jenkins, Clinton N.; Flocks, J.; Kulp, M.; ,
2006-01-01
Information-processing methods are described that integrate the stratigraphic aspects of large and diverse collections of sea-floor sample data. They efficiently convert common types of sea-floor data into database and GIS (geographical information system) tables, visual core logs, stratigraphic fence diagrams and sophisticated stratigraphic statistics. The input data are held in structured documents, essentially written core logs that are particularly efficient to create from raw input datasets. Techniques are described that permit efficient construction of regional databases consisting of hundreds of cores. The sedimentological observations in each core are located by their downhole depths (metres below sea floor - mbsf) and also by a verbal term that describes the sample 'situation' - a special fraction of the sediment or position in the core. The main processing creates a separate output event for each instance of top, bottom and situation, assigning top-base mbsf values from numeric or, where possible, from word-based relative locational information such as 'core catcher' in reference to sampler device, and recovery or penetration length. The processing outputs represent the sub-bottom as a sparse matrix of over 20 sediment properties of interest, such as grain size, porosity and colour. They can be plotted in a range of core-log programs including an in-built facility that better suits the requirements of sea-floor data. Finally, a suite of stratigraphic statistics are computed, including volumetric grades, overburdens, thicknesses and degrees of layering. ?? The Geological Society of London 2006.
Morgan, Clinton D; Zuckerman, Scott L; Lee, Young M; King, Lauren; Beaird, Susan; Sills, Allen K; Solomon, Gary S
2015-06-01
OBJECT Sport-related concussion (SRC) is a major public health problem. Approximately 90% of SRCs in high school athletes are transient; symptoms recover to baseline within 1 week. However, a small percentage of patients remain symptomatic several months after injury, with a condition known as postconcussion syndrome (PCS). The authors aimed to identify risk factors for PCS development in a cohort of exclusively young athletes (9-18 years of age) who sustained SRCs while playing a sport. METHODS The authors conducted a retrospective case-control study by using the Vanderbilt Sports Concussion Clinic database. They identified 40 patients with PCS and matched them by age at injury and sex to SRC control patients (1 PCS to 2 control). PCS patients were those experiencing persistent symptoms at 3 months after an SRC. Control patients were those with documented resolution of symptoms within 3 weeks of an SRC. Data were collected in 4 categories: 1) demographic variables; 2) key medical, psychiatric, and family history; 3) acute-phase postinjury symptoms (at 0-24 hours); and 4) subacute-phase postinjury features (at 0-3 weeks). The chi-square Fisher exact test was used to assess categorical variables, and the Mann-Whitney U-test was used to evaluate continuous variables. Forward stepwise regression models (Pin = 0.05, Pout = 0.10) were used to identify variables associated with PCS. RESULTS PCS patients were more likely than control patients to have a concussion history (p = 0.010), premorbid mood disorders (p = 0.002), other psychiatric illness (p = 0.039), or significant life stressors (p = 0.036). Other factors that increased the likelihood of PCS development were a family history of mood disorders, other psychiatric illness, and migraine. Development of PCS was not predicted by race, insurance status, body mass index, sport, helmet use, medication use, and type of symptom endorsement. A final logistic regression analysis of candidate variables showed PCS to be predicted by a history of concussion (OR 1.8, 95% CI 1.1-2.8, p = 0.016), preinjury mood disorders (OR 17.9, 95% CI 2.9-113.0, p = 0.002), family history of mood disorders (OR 3.1, 95% CI 1.1-8.5, p = 0.026), and delayed symptom onset (OR 20.7, 95% CI 3.2-132.0, p < 0.001). CONCLUSIONS In this age- and sex-matched case-control study of risk factors for PCS among youth with SRC, risk for development of PCS was higher in those with a personal and/or family history of mood disorders, other psychiatric illness, and migraine. These findings highlight the unique nature of SRC in youth. For this population, providers must recognize the value of establishing the baseline health and psychiatric status of children and their primary caregivers with regard to symptom reporting and recovery expectations. In addition, delayed symptom onset was an unexpected but strong risk factor for PCS in this cohort. Delayed symptoms could potentially result in late removal from play, rest, and care by qualified health care professionals. Taken together, these results may help practitioners identify young athletes with concussion who are at a greater danger for PCS and inform larger prospective studies for validation of risk factors from this cohort.
Legarreta, Andrew D; Brett, Benjamin L; Solomon, Gary S; Zuckerman, Scott L
2018-06-01
OBJECTIVE Sport-related concussion (SRC) has become a major public health concern. Prolonged recovery after SRC, named postconcussion syndrome (PCS), has been associated with several biopsychosocial factors, yet the role of both family and personal psychiatric histories requires investigation. In a cohort of concussed high school athletes, the authors examined the role(s) of family and personal psychiatric histories in the risk of developing PCS. METHODS A retrospective cohort study of 154 high school athletes with complete documentation of postconcussion symptom resolution or persistence at 6 weeks was conducted. PCS was defined as 3 or more symptoms present 6 weeks after SRC. Three groups were defined: 1) positive family psychiatric history and personal psychiatric history (FPH/PPH), 2) positive FPH only, and 3) negative family and personal psychiatric histories (controls). Three bivariate regression analyses were conducted: FPH/PPH to controls, FPH only to controls, and FPH/PPH to FPH. Post hoc bivariate regression analyses examined specific FPH pathologies and PCS. RESULTS Athletes with FPH/PPH compared with controls had an increased risk of PCS (χ 2 = 8.90, p = 0.018; OR 5.06, 95% CI 1.71-14.99). Athletes with FPH only compared with controls also had an increased risk of PCS (χ 2 = 6.04, p = 0.03; OR 2.52, 95% CI 1.20-5.30). Comparing athletes with FPH/PPH to athletes with FPH only, no added PCS risk was noted (χ 2 = 1.64, p = 0.247; OR 2.01, 95% CI 0.68-5.94). Among various FPH diagnoses, anxiety (χ 2 = 7.48, p = 0.021; OR 2.99, 95% CI 1.36-6.49) and bipolar disorder (χ 2 = 5.13, p = 0.036; OR 2.74, 95% CI 1.14-6.67) were significantly associated with the presence of PCS. CONCLUSIONS Concussed high school athletes with FPH/PPH were greater than 5 times more likely to develop PCS than controls. Athletes with only FPH were over 2.5 times more likely to develop PCS than controls. Those with an FPH of anxiety or bipolar disorder are specifically at increased risk of PCS. These results suggest that not only are athletes with FPH/PPH at risk for slower recovery after SRC, but those with an FPH only-especially anxiety or bipolar disorder-may also be at risk. Overall, this study supports taking a detailed FPH and PPH in the management of SRC.
Detecting signals of detrimental prescribing cascades from social media.
Hoang, Tao; Liu, Jixue; Pratt, Nicole; Zheng, Vincent W; Chang, Kevin C; Roughead, Elizabeth; Li, Jiuyong
2016-07-01
Prescribing cascade (PC) occurs when an adverse drug reaction (ADR) is misinterpreted as a new medical condition, leading to further prescriptions for treatment. Additional prescriptions, however, may worsen the existing condition or introduce additional adverse effects (AEs). Timely detection and prevention of detrimental PCs is essential as drug AEs are among the leading causes of hospitalization and deaths. Identifying detrimental PCs would enable warnings and contraindications to be disseminated and assist the detection of unknown drug AEs. Nonetheless, the detection is difficult and has been limited to case reports or case assessment using administrative health claims data. Social media is a promising source for detecting signals of detrimental PCs due to the public availability of many discussions regarding treatments and drug AEs. In this paper, we investigate the feasibility of detecting detrimental PCs from social media. The detection, however, is challenging due to the data uncertainty and data rarity in social media. We propose a framework to mine sequences of drugs and AEs that signal detrimental PCs, taking into account the data uncertainty and data rarity. We conduct experiments on two real-world datasets collected from Twitter and Patient health forum. Our framework achieves encouraging results in the validation against known detrimental PCs (F1=78% for Twitter and 68% for Patient) and the detection of unknown potential detrimental PCs (Precision@50=72% and NDCG@50=95% for Twitter, Precision@50=86% and NDCG@50=98% for Patient). In addition, the framework is efficient and scalable to large datasets. Our study demonstrates the feasibility of generating hypotheses of detrimental PCs from social media to reduce pharmacists' guesswork. Copyright © 2016 Elsevier B.V. All rights reserved.
Prediction of solar activity from solar background magnetic field variations in cycles 21-23
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shepherd, Simon J.; Zharkov, Sergei I.; Zharkova, Valentina V., E-mail: s.j.shepherd@brad.ac.uk, E-mail: s.zharkov@hull.ac.uk, E-mail: valentina.zharkova@northumbria.ac.uk
2014-11-01
A comprehensive spectral analysis of both the solar background magnetic field (SBMF) in cycles 21-23 and the sunspot magnetic field in cycle 23 reported in our recent paper showed the presence of two principal components (PCs) of SBMF having opposite polarity, e.g., originating in the northern and southern hemispheres, respectively. Over a duration of one solar cycle, both waves are found to travel with an increasing phase shift toward the northern hemisphere in odd cycles 21 and 23 and to the southern hemisphere in even cycle 22. These waves were linked to solar dynamo waves assumed to form in differentmore » layers of the solar interior. In this paper, for the first time, the PCs of SBMF in cycles 21-23 are analyzed with the symbolic regression technique using Hamiltonian principles, allowing us to uncover the underlying mathematical laws governing these complex waves in the SBMF presented by PCs and to extrapolate these PCs to cycles 24-26. The PCs predicted for cycle 24 very closely fit (with an accuracy better than 98%) the PCs derived from the SBMF observations in this cycle. This approach also predicts a strong reduction of the SBMF in cycles 25 and 26 and, thus, a reduction of the resulting solar activity. This decrease is accompanied by an increasing phase shift between the two predicted PCs (magnetic waves) in cycle 25 leading to their full separation into the opposite hemispheres in cycle 26. The variations of the modulus summary of the two PCs in SBMF reveals a remarkable resemblance to the average number of sunspots in cycles 21-24 and to predictions of reduced sunspot numbers compared to cycle 24: 80% in cycle 25 and 40% in cycle 26.« less
Procyanidin and catechin contents and antioxidant capacity of cocoa and chocolate products.
Gu, Liwei; House, Suzanne E; Wu, Xianli; Ou, Boxin; Prior, Ronald L
2006-05-31
Cocoa and chocolate products from major brands were analyzed blind for total antioxidant capacity (AOC) (lipophilic and hydrophilic ORAC(FL)), catechins, and procyanidins (monomer through polymers). Accuracy of analyses was ascertained by comparing analyses on a NIST standard reference chocolate with NIST certified values. Procyanidin (PC) content was related to the nonfat cocoa solid (NFCS) content. The natural cocoa powders (average 87% of NFCS) contained the highest levels of AOC (826 +/- 103 micromol of TE/g) and PCs (40.8 +/- 8.3 mg/g). Alkalized cocoa (Dutched powders, average 80% NFCS) contained lower AOC (402 +/- 6 micromol of TE /g) and PCs (8.9 +/- 2.7 mg/g). Unsweetened chocolates or chocolate liquor (50% NFCS) contained 496 +/- 40 micromol of TE /g of AOC and 22.3 +/- 2.9 mg/g of PCs. Milk chocolates, which contain the least amount of NFCS (7.1%), had the lowest concentrations of AOC (80 +/- 10 micromol of TE /g) and PCs (2.7 +/- 0.5 mg/g). One serving of cocoa (5 g) or chocolate (15 or 40 g, depending upon the type of chocolate) provides 2000-9100 micromol of TE of AOC and 45-517 mg of PCs, amounts that exceed the amount in a serving of the majority of foods consumed in America. The monomers through trimers, which are thought to be directly bioavailable, contributed 30% of the total PCs in chocolates. Hydrophilic antioxidant capacity contributed >90% of AOC in all products. The correlation coefficient between AOC and PCs in chocolates was 0.92, suggesting that PCs are the dominant antioxidants in cocoa and chocolates. These results indicate that NFCS is correlated with AOC and PC in cocoa and chocolate products. Alkalizing dramatically decreased both the procyanidin content and antioxidant capacity, although not to the same extent.
Kusano, Kristofer D; Gabler, Hampton C
2010-01-01
To mitigate the severity of rear-end and other collisions, Pre-Crash Systems (PCS) are being developed. These active safety systems utilize radar and/or video cameras to determine when a frontal crash, such as a front-to-back rear-end collisions, is imminent and can brake autonomously, even with no driver input. Of these PCS features, the effects of autonomous pre-crash braking are estimated. To estimate the maximum potential for injury reduction due to autonomous pre-crash braking in the striking vehicle of rear-end crashes, a methodology is presented for determining 1) the reduction in vehicle crash change in velocity (ΔV) due to PCS braking and 2) the number of injuries that could be prevented due to the reduction in collision severity. Injury reduction was only performed for belted drivers, as unbelted drivers have an unknown risk of being thrown out of position. The study was based on 1,406 rear-end striking vehicles from NASS / CDS years 1993 to 2008. PCS parameters were selected from realistic values and varied to examine the effect on system performance. PCS braking authority was varied from 0.5 G's to 0.8 G's while time to collision (TTC) was held at 0.45 seconds. TTC was then varied from 0.3 second to 0.6 seconds while braking authority was held constant at 0.6 G's. A constant braking pulse (step function) and ramp-up braking pulse were used. The study found that automated PCS braking could reduce the crash ΔV in rear-end striking vehicles by an average of 12% - 50% and avoid 0% - 14% of collisions, depending on PCS parameters. Autonomous PCS braking could potentially reduce the number of injured drivers who are belted by 19% to 57%.
Arguello, Blanca; Salgado, Teresa M; Fernandez-Llimos, Fernando
2015-01-01
Aims To assess the completeness and applicability of information for the use of medicines in pregnancy and lactation contained in European Summaries of Product Characteristics (SmPCs). Methods SmPCs available on the EMA website in April 2011 were retrieved, and information on the use of medicines during pregnancy and lactation was analyzed. A form was designed to extract information regarding drug concentrations crossing the placenta, excretion of the drug in milk, the existence of pre-clinical and clinical studies and clinical experience describing the use of the medicine in pregnancy and lactation, medicine effects on human fertility, medicines use in women of child-bearing potential and specific recommendations for use during pregnancy and breastfeeding. SmPCs were classified as containing ‘conclusive’ or ‘ambiguous’ information depending on whether (or not) they provided clear instructions regarding medicine use in pregnancy and lactation. Results Of the 534 SmPCs, 89.3% did not mention whether the drug crossed the placenta, 67.6% indicated that there was no clinical experience during pregnancy and in 61.4% it was unknown whether the medicine was excreted in human milk. Recommendations for medicine use during pregnancy and breastfeeding were ambiguous in 57.0% and 16.5% of the SmPCs, respectively, and medicine use was restricted in over 90% SmPCs for both pregnancy and breastfeeding, despite no information supporting these restrictions being reported. The time elapsed since a SmPCs first approval was not associated with an increase in information quality. Conclusions Important information deficits on the use of medicines during pregnancy and breastfeeding were found in European SmPCs. PMID:25224071
Arguello, Blanca; Salgado, Teresa M; Fernandez-Llimos, Fernando
2015-03-01
To assess the completeness and applicability of information for the use of medicines in pregnancy and lactation contained in European Summaries of Product Characteristics (SmPCs). SmPCs available on the EMA website in April 2011 were retrieved, and information on the use of medicines during pregnancy and lactation was analyzed. A form was designed to extract information regarding drug concentrations crossing the placenta, excretion of the drug in milk, the existence of pre-clinical and clinical studies and clinical experience describing the use of the medicine in pregnancy and lactation, medicine effects on human fertility, medicines use in women of child-bearing potential and specific recommendations for use during pregnancy and breastfeeding. SmPCs were classified as containing 'conclusive' or 'ambiguous' information depending on whether (or not) they provided clear instructions regarding medicine use in pregnancy and lactation. Of the 534 SmPCs, 89.3% did not mention whether the drug crossed the placenta, 67.6% indicated that there was no clinical experience during pregnancy and in 61.4% it was unknown whether the medicine was excreted in human milk. Recommendations for medicine use during pregnancy and breastfeeding were ambiguous in 57.0% and 16.5% of the SmPCs, respectively, and medicine use was restricted in over 90% SmPCs for both pregnancy and breastfeeding, despite no information supporting these restrictions being reported. The time elapsed since a SmPCs first approval was not associated with an increase in information quality. Important information deficits on the use of medicines during pregnancy and breastfeeding were found in European SmPCs. © 2014 The British Pharmacological Society.
Rutten, Marianne J; van Meurs, Hannah S; van de Vrie, Roelien; Gaarenstroom, Katja N; Naaktgeboren, Christiana A; van Gorp, Toon; Ter Brugge, Henk G; Hofhuis, Ward; Schreuder, Henk W R; Arts, Henriette J G; Zusterzeel, Petra L M; Pijnenborg, Johanna M A; van Haaften, Maarten; Fons, Guus; Engelen, Mirjam J A; Boss, Erik A; Vos, M Caroline; Gerestein, Kees G; Schutter, Eltjo M J; Opmeer, Brent C; Spijkerboer, Anje M; Bossuyt, Patrick M M; Mol, Ben Willem; Kenter, Gemma G; Buist, Marrije R
2017-02-20
Purpose To investigate whether initial diagnostic laparoscopy can prevent futile primary cytoreductive surgery (PCS) by identifying patients with advanced-stage ovarian cancer in whom > 1 cm of residual disease will be left after PCS. Patients and Methods This multicenter, randomized controlled trial was undertaken within eight gynecologic cancer centers in the Netherlands. Patients with suspected advanced-stage ovarian cancer who qualified for PCS were eligible. Participating patients were randomly assigned to either laparoscopy or PCS. Laparoscopy was used to guide selection of primary treatment: either primary surgery or neoadjuvant chemotherapy followed by interval surgery. The primary outcome was futile laparotomy, defined as a PCS with residual disease of > 1 cm. Primary analyses were performed according to the intention-to-treat principle. Results Between May 2011 and February 2015, 201 participants were included, of whom 102 were assigned to diagnostic laparoscopy and 99 to primary surgery. In the laparoscopy group, 63 (62%) of 102 patients underwent PCS versus 93 (94%) of 99 patients in the primary surgery group. Futile laparotomy occurred in 10 (10%) of 102 patients in the laparoscopy group versus 39 (39%) of 99 patients in the primary surgery group (relative risk, 0.25; 95% CI, 0.13 to 0.47; P < .001). In the laparoscopy group, three (3%) of 102 patients underwent both primary and interval surgery compared with 28 (28%) of 99 patients in the primary surgery group ( P < .001). Conclusion Diagnostic laparoscopy reduced the number of futile laparotomies in patients with suspected advanced-stage ovarian cancer. In women with a plan for PCS, these data suggest that performance of diagnostic laparoscopy first is reasonable and that if cytoreduction to < 1 cm of residual disease seems feasible, to proceed with PCS.
NASA Astrophysics Data System (ADS)
Rietmeijer, Frans J. M.
1997-03-01
Chondritic porous (CP) interplanetary dust particles (IDPs) can be described as 'cosmic sediments'. It should be possible to recognize in these IDPs the 4500 Myrs old solar nebula dusts. The studies of unaltered chondritic IDPs show that their matrices are a mixture of three different principal components (PCs) that also describe variable C/Si ratios of chondritic IDPs. Among others, PCs include polyphase units (PUs) that are amorphous to holocrystalline, both ultrafine- and coarse-grained, ferromagnesiosilica(te) materials with minor Al and Ca. The properties of PCs and their alteration products define the physical and chemical processes that produced and altered these components. PCs are also cornerstones of IDP classification. For example, the bulk composition of ultrafine-grained PCs can be reconstructed using the 'butterfly method' and also allows an evaluation of the metamorphic signatures, (e.g., dynamic pyrometamorphism), in chondritic IDPs.
Three-dimensional function photonic crystals
NASA Astrophysics Data System (ADS)
Zhang, Hai-Feng
2017-11-01
In this paper, the properties of the photonic band gaps (PBGs) of three-dimensional (3D) function photonic crystals (PCs) are theoretically investigated by a modified plane wave expansion (PWE) method, whose equations for computations are deduced. The configuration of 3D function PCs is the dielectric spheres inserted in the air background with simple-cubic (SC) lattices whose dielectric constants are the functions of space coordinates, which can be realized by the electro-optical or optical Kerr effect in the practice. The influences of the parameter for 3D function PCs on the PBGs also are discussed. The calculated results show that the bandwidths and number of PBGs can be tuned with different distributions of function dielectrics. Compared with the conventional 3D dielectric PCs with SC lattices, the larger and more PBGs can be obtained in the 3D function PCs. Those results provide a new way to design the novel practical devices.
Effect of ZrO2 Powders on the Pyrolysis of Polycarbosilanes Coating Under Laser Ablation
NASA Astrophysics Data System (ADS)
Cheng, Han; Chen, Zhaofeng; Tao, Jie; Yan, Bo; Li, Cong; Wang, Liangbing; Zhang, Ying; Fang, Dan; Wan, Shuicheng; Wu, Wangping
Aircrafts hold the outstanding mastery of the sky in modern wars, however the laser beam weapons can carry out laser attacking to aircrafts. The purpose of the present paper is to research on a new type laser protective material. Polycarbosilanes (PCS)/divinylbenzene mixtures containing ZrO2 powders were brushed to the surface of the aluminum alloy plates and then cured at 150°C for 6 h. The PCS-coated plates were ablated by laser for 3 s. The phase identification of as-ablated powders was examined by X-ray diffraction. The results indicated that the as-ablated powders of cured PCS were composed of major phase β-SiC and smaller amounts of free carbon. The PCS composite coating played a certain role of laser ablation resistance. The effect of added ZrO2 powders on the pyrolysis of PCS-coating under laser ablation is conspicuous.
MHD simulation of plasma compression experiments
NASA Astrophysics Data System (ADS)
Reynolds, Meritt; Barsky, Sandra; de Vietien, Peter
2017-10-01
General Fusion (GF) is working to build a magnetized target fusion (MTF) power plant based on compression of magnetically-confined plasma by liquid metal. GF is testing this compression concept by collapsing solid aluminum liners onto plasmas formed by coaxial helicity injection in a series of experiments called PCS (Plasma Compression, Small). We simulate the PCS experiments using the finite-volume MHD code VAC. The single-fluid plasma model includes temperature-dependent resistivity and anisotropic heat transport. The time-dependent curvilinear mesh for MHD simulation is derived from LS-DYNA simulations of actual field tests of liner implosion. We will discuss how 3D simulations reproduced instability observed in the PCS13 experiment and correctly predicted stabilization of PCS14 by ramping the shaft current during compression. We will also present a comparison of simulated Mirnov and x-ray diagnostics with experimental measurements indicating that PCS14 compressed well to a linear compression ratio of 2.5:1.
Marcoux, Geneviève; Duchez, Anne-Claire; Rousseau, Matthieu; Lévesque, Tania; Boudreau, Luc H; Thibault, Louis; Boilard, Eric
2017-05-01
On activation, platelets release vesicles called microparticles (MPs). MPs are heterogeneous with regard to the presence or absence of mitochondria. We quantified MPs in platelet concentrates (PCs) taking their mitochondrial content into account. Platelet-rich plasma (PRP), buffy coat (BC) and apheresis (AP) PCs were tested through 7 days of storage. A combination of flow cytometry and spanning-tree progression analysis of density-normalized events (SPADE) was used to determine MP and mitochondrial release during storage. All the PC biochemical parameters complied with transfusion standards at all times. Platelet activation markers increased during storage and were higher for PRP than other types of PCs. Concentrations of MPs and extracellular mitochondria interpreted by SPADE algorithm were significantly higher in PRP than other in PCs and were stable throughout storage. The mode of preparation, rather than storage duration, impacts the release of MPs and mitochondria in PCs.
Dean, Philip J A; Otaduy, Maria C G; Harris, Lisa M; McNamara, Adam; Seiss, Ellen; Sterr, Annette
2013-08-21
This pilot study explores the metabolic changes associated with persistent postconcussion syndrome (PCS) after mild traumatic brain injury (mTBI; >12 months after injury) using magnetic resonance spectroscopy. We hypothesized that those mTBI participants with PCS will have larger metabolic differences than those without. Data were collected from mTBI participants with PCS, mTBI participants without PCS and non-head-injured participants (all groups: n=8). Magnetic resonance spectroscopy metabolite profiles within the dorsolateral prefrontal cortex showed a reduced creatine/choline ratio in mTBI patients compared with control participants. This data provides initial evidence for residual metabolic changes in chronic mTBI patients, but there was no conclusive relationship between these metabolic changes and PCS symptom report. Creatine is involved in maintaining energy levels in cells with high or fluctuating energy demand, suggesting that there may be some residual energy impairment in chronic mTBI.
Kawamura, Yoichiro; Katada, Sayako; Noguchi, Hirofumi; Yamamoto, Hiroyuki; Sanosaka, Tsukasa; Iihara, Koji; Nakashima, Kinichi
2017-11-01
Astrocytes, which support diverse neuronal functions, are generated from multipotent neural stem/precursor cells (NS/PCs) during brain development. Although many astrocyte-inducing factors have been identified and studied in vitro, the regions and/or cells that produce these factors in the developing brain remain elusive. Here, we show that meninges-produced factors induce astrocytic differentiation of NS/PCs. Consistent with the timing when astrocytic differentiation of NS/PCs increases, expression of astrocyte-inducing factors is upregulated. Meningeal secretion-mimicking combinatorial treatment of NS/PCs with bone morphogenetic protein 4, retinoic acid and leukemia inhibitory factor synergistically activate the promoter of a typical astrocytic marker, glial fibrillary acidic protein. Taken together, our data suggest that meninges play an important role in astrocytic differentiation of NS/PCs in the developing brain. © 2017 Federation of European Biochemical Societies.
Use of Passive Diffusion Samplers for Monitoring Volatile Organic Compounds in Ground Water
Harte, Philip T.; Brayton, Michael J.; Ives, Wayne
2000-01-01
Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC's) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC's in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: * Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. * Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. * Reduction in sampling time by as much as 80 percent of that required for 'purge type' sampling methods. * An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krochmal, D.; Gorski, L.
1991-03-01
The effects of temperature, humidity, and storage on a diffusive sampler were tested by use of the Amaya-Sugiura method, modified previously. Several materials were used as carriers for triethanolamine in the sampler. The mass of NO{sub 2} absorbed in the sampler was determined spectrophotometrically as nitrite by using Saltzman solution. The collection efficiency of the sampler was lower than that calculated from Fick's law of diffusion due to significant contribution of liquid phase in the overall sampler diffusive resistance. This resulted in an increase of the mass of NO{sub 2} absorbed in the sampler by ca. 20% per 10{degree}C ofmore » temperature growth and by ca. 25% when the relative humidity rose from 0 to 100%. Dependence of concentration of TEA solution in the sampler on the relative humidity of the air was noted. The relative precision of the method characterized by RSD was 10%; the detection limit of NO{sub 2} was 10 {mu}g/m{sup 3} for a 24-h exposure.« less
A new device for collecting time-integrated water samples from springs and surface water bodies
Panno, S.V.; Krapac, I.G.; Keefer, D.A.
1998-01-01
A new device termed the 'seepage sampler' was developed to collect representative water samples from springs, streams, and other surface-water bodies. The sampler collects composite, time-integrated water samples over short (hours) or extended (weeks) periods without causing significant changes to the chemical composition of the samples. The water sample within the sampler remains at the ambient temperature of the water body and does not need to be cooled. Seepage samplers are inexpensive to construct and easy to use. A sampling program of numerous springs and/or streams can be designed at a relatively low cost through the use of these samplers. Transient solutes migrating through such flow systems, potentially unnoticed by periodic sampling, may be detected. In addition, the mass loading of solutes (e.g., agrichemicals) may be determined when seepage samplers are used in conjunction with discharge measurements.
ERIC Educational Resources Information Center
Ellington, Aimee J.; Wilson, Jill H.; Nugent, Jeffrey S.
2011-01-01
This article details the use of tablet PCs in a mathematics content course for future Mathematics Specialists. Instructors used tablet PCs instead of a traditional whiteboard to capture demonstration and discussion. Students were grouped for collaborative problem solving and exploration exercises. Each group was provided with a tablet PC for…
PCS: a pallet costing system for wood pallet manufacturers (version 1.0 for Windows®)
A. Jefferson, Jr. Palmer; Cynthia D. West; Bruce G. Hansen; Marshall S. White; Hal L. Mitchell
2002-01-01
The Pallet Costing System (PCS) is a computer-based, Microsoft Windows® application that computes the total and per-unit cost of manufacturing an order of wood pallets. Information about the manufacturing facility, along with the pallet-order requirements provided by the customer, is used in determining production cost. The major cost factors addressed by PCS...
Evidence of non-classical (squeezed) light in biological systems
NASA Astrophysics Data System (ADS)
Popp, F. A.; Chang, J. J.; Herzog, A.; Yan, Z.; Yan, Y.
2002-01-01
By use of coincidence measurements on “ultraweak” photon emission, the photocount statistics (PCS) of artificial visible light turns out to follow-as expected-super-Poissonian PCS. Biophotons, originating from spontaneous or light-induced living systems, display super-Poissonian, Poissonian and even sub-Poissonian PCS. This result shows the first time evidence of non-classical (squeezed) light in living tissues.
Active Rehabilitation of Concussion and Post-concussion Syndrome.
Leddy, John J; Baker, John G; Willer, Barry
2016-05-01
Concussion is a physiological brain injury with physical, cognitive, and emotional sequelae. The macrophysiological insult to the brain affects the autonomic nervous system and its control of cerebral blood flow. Most patients recover within 2 weeks, but some do not. Persistence of symptoms beyond the generally accepted time frame for recovery is called post-concussion syndrome (PCS). PCS is not a single entity; it is a group of disorders that requires specific forms of therapy. Rest has been the mainstay of the treatment for concussion and PCS. This article discusses the rationale for the active treatment of concussion and PCS. Copyright © 2016 Elsevier Inc. All rights reserved.
Religiousness and prostate cancer screening in African American men.
Abernethy, Alexis D; Houston, Tina R; Bjorck, Jeffrey P; Gorsuch, Richard L; Arnold, Harold L
2009-01-01
This study was designed to examine the relationship between religiousness (organized, nonorganized, and intrinsic) and religious problem solving (collaborative, deferring, and self-directing) in prostate cancer screening (PCS) attitudes and behavior. Men (N = 481) of African descent between the ages of 40 and 70 participated. Hierarchical regression analyses revealed that religiousness and self-directed problem solving were associated with PCS attitudes. Intrinsic religiousness was associated with PCS attitudes after controlling for health and organized religiousness. Religiousness was not associated with PCS behavior. Intrinsic religiousness may be an important dimension of religiousness to be considered in tailoring cancer interventions for individuals from faith-based communities.
Tomihama, Tsuyoshi; Nishi, Yatsuka; Mori, Kiyofumi; Shirao, Tsukasa; Iida, Toshiya; Uzuhashi, Shihomi; Ohkuma, Moriya; Ikeda, Seishi
2016-07-01
Potato common scab (PCS), caused by pathogenic Streptomyces spp., is a serious disease in potato production worldwide. Cultural practices, such as optimizing the soil pH and irrigation, are recommended but it is often difficult to establish stable disease reductions using these methods. Traditionally, local farmers in southwest Japan have amended soils with rice bran (RB) to suppress PCS. However, the scientific mechanism underlying disease suppression by RB has not been elucidated. The present study showed that RB amendment reduced PCS by repressing the pathogenic Streptomyces population in young tubers. Amplicon sequencing analyses of 16S ribosomal RNA genes from the rhizosphere microbiome revealed that RB amendment dramatically changed bacterial composition and led to an increase in the relative abundance of gram-positive bacteria such as Streptomyces spp., and this was negatively correlated with PCS disease severity. Most actinomycete isolates derived from the RB-amended soil showed antagonistic activity against pathogenic Streptomyces scabiei and S. turgidiscabies on R2A medium. Some of the Streptomyces isolates suppressed PCS when they were inoculated onto potato plants in a field experiment. These results suggest that RB amendment increases the levels of antagonistic bacteria against PCS pathogens in the potato rhizosphere.
Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Bartley, David L; Slaven, James E; Andrew, Michael E
2007-11-01
This paper concludes a five-year program on research into the use of a portable X-ray fluorescence (XRF) analyzer for analyzing lead in air sampling filters from different industrial environments, including mining, manufacturing and recycling. The results from four of these environments have already been reported. The results from two additional metal processes are presented here. At both of these sites, lead was a minor component of the total airborne metals and interferences from other elements were minimal. Nevertheless, only results from the three sites where lead was the most abundant metal were used in the overall calculation of method accuracy. The XRF analyzer was used to interrogate the filters, which were then subjected to acid digestion and analysis by inductively-coupled plasma optical-emission spectroscopy (ICP-OES). The filter samples were collected using different filter-holders or "samplers" where the size (diameter), depth and homogeneity of aerosol deposit varied from sampler to sampler. The aerosol collection efficiencies of the samplers were expected to differ, especially for larger particles. The distribution of particles once having entered the sampler was also expected to differ between samplers. Samplers were paired to allow the between-sampler variability to be addressed, and, in some cases, internal sampler wall deposits were evaluated and compared to the filter catch. It was found, rather surprisingly, that analysis of the filter deposits (by ICP-OES) of all the samplers gave equivalent results. It was also found that deposits on some of the sampler walls, which in some protocols are considered part of the sample, could be significant in comparison to the filter deposit. If it is concluded that wall-deposits should be analyzed, then XRF analysis of the filter can only give a minimum estimate of the concentration. Techniques for the statistical analysis of field data were also developed as part of this program and have been reported elsewhere. The results, based on data from the three workplaces where lead was the major element present in the samples, are summarized here. A limit of detection and a limit of quantitation are provided. Analysis of some samples using a second analyzer with a different X-ray source technology indicated reasonable agreement for some metals (but this was not evaluated for lead). Provided it is only necessary to analyze the filters, most personal samplers will provide acceptable results when used with portable XRF analysis for lead around applicable limit values.
High speed sampler and demultiplexer
McEwan, T.E.
1995-12-26
A high speed sampling demultiplexer based on a plurality of sampler banks, each bank comprising a sample transmission line for transmitting an input signal, a strobe transmission line for transmitting a strobe signal, and a plurality of sampling gates at respective positions along the sample transmission line for sampling the input signal in response to the strobe signal. Strobe control circuitry is coupled to the plurality of banks, and supplies a sequence of bank strobe signals to the strobe transmission lines in each of the plurality of banks, and includes circuits for controlling the timing of the bank strobe signals among the banks of samplers. Input circuitry is included for supplying the input signal to be sampled to the plurality of sample transmission lines in the respective banks. The strobe control circuitry can repetitively strobe the plurality of banks of samplers such that the banks of samplers are cycled to create a long sample length. Second tier demultiplexing circuitry is coupled to each of the samplers in the plurality of banks. The second tier demultiplexing circuitry senses the sample taken by the corresponding sampler each time the bank in which the sampler is found is strobed. A plurality of such samples can be stored by the second tier demultiplexing circuitry for later processing. Repetitive sampling with the high speed transient sampler induces an effect known as ``strobe kickout``. The sample transmission lines include structures which reduce strobe kickout to acceptable levels, generally 60 dB below the signal, by absorbing the kickout pulses before the next sampling repetition. 16 figs.
Vroblesky, Don A.; Peters, Brian C.
2000-01-01
Volatile organic compound concentrations in water from diffusion samplers were compared to concentrations in water obtained by low-flow purging at 15 observation wells at the Naval Air Station North Island, San Diego, California. Multiple diffusion samplers were installed in the wells. In general, comparisons using bladder pumps and diffusion samplers showed similar volatile organic carbon concentrations. In some wells, sharp concentration gradients were observed, such as an increase in cis-1,2-dichloroethene concentration from 100 to 2,600 micrograms per liter over a vertical distance of only 3.4 feet. In areas where such sharp gradients were observed, concentrations in water obtained by low-flow sampling at times reflected an average concentration over the area of influence; however, concentrations obtained by using the diffusion sampler seemed to represent the immediate vicinity of the sampler. When peristaltic pumps were used to collect ground-water samples by low-flow purging, the volatile organic compound concentrations commonly were lower than concentrations obtained by using diffusion samplers. This difference may be due to loss of volatiles by degassing under negative pressures in the sampling lines induced while using the peristaltic pump, mixing in the well screen, or possible short-circuiting of water from an adjacent depth. Diffusion samplers placed in buckets of freephase jet fuel (JP-5) and Stoddard solvent from observation wells did not show evidence of structural integrity loss during the 2 months of equilibration, and volatile organic compounds detected in the free-phase fuel also were detected in the water from the diffusion samplers.
Stern, Marilyn; Ewing, Lin; Davila, Esther; Thompson, Amanda L; Hale, Gregory; Mazzeo, Suzanne
2015-03-01
Approximately 40% of off-treatment pediatric cancer survivors (PCS) are overweight or obese, which increases their risk for negative long-term physical health complications. Consistent with the Institute of Medicine's (IOM) emphasis on patients transitioning from treatment to cancer survivorship and increasing long-term healthy behaviors in these survivors, we plan to conduct a pilot RCT to address the increasing overweight/obesity rates among PCS by targeting their caregivers as agents for PCS behavior change. We plan to focus on parents' behaviors, attitudes and roles in promoting healthier eating and physical activity (PA) in PCS and adapt an evidence-informed, manualized parent intervention - NOURISH - found to be effective for parents of overweight and obese children and adolescents in reducing child and adolescent BMI. We plan to adapt NOURISH for caregivers of 5-12 year old PCS (6 months-4 years off active cancer treatment). Our pilot feasibility RCT - NOURISH-T (Nourishing Our Understanding of Role modeling to Improve Support for Healthy Transitions) evaluates: 1) the preliminary efficacy of NOURISH-T for PCS, compared with an Enhanced Usual Care (EUC) control condition, and 2) factors to consider to improve future adaptations of the intervention. The project will enroll caregivers of PCS at two pediatric oncology clinics into the 6-week intervention (or EUC) with assessments occurring pre- and post-6 weeks of intervention, and at a 4-month follow-up. Copyright © 2015 Elsevier Inc. All rights reserved.
Rogowska, Anna; Chabowska, Anna Małgorzata; Lipska, Alina; Boczkowska-Radziwon, Barbara; Bujno, Magdalena; Rusak, Tomasz; Dziemianczuk, Mateusz; Radziwon, Piotr
2016-05-01
In radiofrequency identification (RFID) systems used in labeling of blood components, blood cells are subjected to the direct influence of electromagnetic waves throughout the storage period. The aim of this study was to prove the safety of storage of platelet concentrates (PCs) in containers labeled with RFID tags. Ten pooled PCs obtained from 12 buffy coats each suspended in additive solution were divided into three separate containers that were assigned to three groups: control, PCs labeled with ultrahigh frequency (UHF) range tags and exposed to 915-MHz radio waves, and PCs labeled with high-frequency (HF) range tags and exposed to 13.56-MHz radio waves. PCs were stored at 20 to 24°C for 7 days. In vitro tests of platelet (PLT) function were performed on the first, fifth, and seventh days of storage. There were no significant differences in pH; hypotonic shock resistance; surface expression of CD62P, CD42a, or CD63; release of PLT-derived microparticles; PLT aggregation; and number of PLTs between PCs stored at a constant exposure to radio waves of two different frequencies and the control group on the first, fifth, and seventh days of storage. The results of the study indicate no impact of electromagnetic radiation generated in HF and UHF RFID systems and constant contact with the tags on the quality of stored PCs. © 2016 AABB.
Learner-centred mathematics and statistics education using netbook tablet PCs
NASA Astrophysics Data System (ADS)
Loch, Birgit; Galligan, Linda; Hobohm, Carola; McDonald, Christine
2011-10-01
Tablet technology has been shown to support learner-centred mathematics education when this technology is available to both the lecturer and the students. However, cost is often the barrier to students' use of tablet PCs for their university studies. This article argues that more affordable netbook PCs with tablet capabilities can be viable alternatives to full-sized tablet PCs to enhance active and collaborative learning in mathematics and statistics. For a whole teaching semester, netbook tablet PCs were given to volunteer students from two different cohorts. Students were enrolled in nursing mathematics or introductory statistics in non-mathematics majors at an Australian university. The aims were to gauge the suitability of this technology and to identify what active and collaborative learning emerged in these first-year classes. While the netbook tablet PCs were actively promoted in their tutorials, of additional interest was students' use of the technology for any aspect of their studies both inside and outside the classroom. The outcome of this study was to inform a university decision to provide inexpensive tablet technology to larger cohorts of students. The results highlight different approaches required in the mathematics and statistics classes to achieve collaborative and active learning facilitated through the technology. Environmental variables such as the tutor, student, learning space, availability of other technologies and subject content had an impact on the nature of learning. While learner-centred education can be facilitated by inexpensive netbook tablet PCs, we caution that the savings may come at the expense of computing power.
Murao, Naoya; Matsubara, Shuzo; Matsuda, Taito; Noguchi, Hirofumi; Mutoh, Tetsuji; Mutoh, Masahiro; Koseki, Haruhiko; Namihira, Masakazu; Nakashima, Kinichi
2018-05-31
Adult neurogenesis is a process of generating new neurons from neural stem/precursor cells (NS/PCs) in restricted adult brain regions throughout life. It is now generally known that adult neurogenesis in the hippocampal dentate gyrus (DG) and subventricular zone participates in various higher brain functions, such as learning and memory formation, olfactory discrimination and repair after brain injury. However, the mechanisms underlying adult neurogenesis remain to be fully understood. Here, we show that Nuclear protein 95 KDa (Np95, also known as UHRF1 or ICBP90), which is an essential protein for maintaining DNA methylation during cell division, is involved in multiple processes of adult neurogenesis. Specific ablation of Np95 in adult NS/PCs (aNS/PCs) led to a decrease in their proliferation and an impairment of neuronal differentiation and to suppression of neuronal maturation associated with the impairment of dendritic formation in the hippocampal DG. We also found that deficiency of Np95 in NS/PCs increased the expression of tumor suppressor genes p16 and p53, and confirmed that expression of these genes in NS/PCs recapitulates the phenotype of Np95-deficient NS/PCs. Taken together, our findings suggest that Np95 plays an essential role in proliferation and differentiation of aNS/PCs through the regulation of tumor suppressor gene expression in adult neurogenesis. Copyright © 2018 Elsevier B.V. and Japan Neuroscience Society. All rights reserved.
Secondary immunization generates clonally related antigen-specific plasma cells and memory B cells.
Frölich, Daniela; Giesecke, Claudia; Mei, Henrik E; Reiter, Karin; Daridon, Capucine; Lipsky, Peter E; Dörner, Thomas
2010-09-01
Rechallenge with T cell-dependent Ags induces memory B cells to re-enter germinal centers (GCs) and undergo further expansion and differentiation into plasma cells (PCs) and secondary memory B cells. It is currently not known whether the expanded population of memory B cells and PCs generated in secondary GCs are clonally related, nor has the extent of proliferation and somatic hypermutation of their precursors been delineated. In this study, after secondary tetanus toxoid (TT) immunization, TT-specific PCs increased 17- to 80-fold on days 6-7, whereas TT-specific memory B cells peaked (delayed) on day 14 with a 2- to 22-fold increase. Molecular analyses of V(H)DJ(H) rearrangements of individual cells revealed no major differences of gene usage and CDR3 length between TT-specific PCs and memory B cells, and both contained extensive evidence of somatic hypermutation with a pattern consistent with GC reactions. This analysis identified clonally related TT-specific memory B cells and PCs. Within clusters of clonally related cells, sequences shared a number of mutations but also could contain additional base pair changes. The data indicate that although following secondary immunization PCs can derive from memory B cells without further somatic hypermutation, in some circumstances, likely within GC reactions, asymmetric mutation can occur. These results suggest that after the fate decision to differentiate into secondary memory B cells or PCs, some committed precursors continue to proliferate and mutate their V(H) genes.
Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water.
Ahrens, Lutz; Daneshvar, Atlasi; Lau, Anna E; Kreuger, Jenny
2016-08-03
Five different water passive samplers were calibrated under laboratory conditions for measurement of 124 legacy and current used pesticides. This study provides a protocol for the passive sampler preparation, calibration, extraction method and instrumental analysis. Sampling rates (RS) and passive sampler-water partition coefficients (KPW) were calculated for silicone rubber, polar organic chemical integrative sampler POCIS-A, POCIS-B, SDB-RPS and C18 disk. The uptake of the selected compounds depended on their physicochemical properties, i.e., silicone rubber showed a better uptake for more hydrophobic compounds (log octanol-water partition coefficient (KOW) > 5.3), whereas POCIS-A, POCIS-B and SDB-RPS disk were more suitable for hydrophilic compounds (log KOW < 0.70).
Comparison of flume and towing methods for verifying the calibration of a suspended-sediment sampler
Beverage, J.P.; Futrell, J.C.
1986-01-01
Suspended-sediment samplers must sample isokinetically (at stream velocity) in order to collect representative water samples of rivers. Each sampler solo by the Federal Interagency Sedimentation Project or by the U.S. Geological Survey Hydrologic Instrumentation Facility has been adjusted to sample isokinetically and tested in a flume to verify the calibration. The test program for a modified U.S. P-61 sampler provided an opportunity to compare flume and towing tank tests. Although the two tests yielded statistically distinct results, the difference between them was quite small. The conclusion is that verifying the calibration of any suspended-sediment sampler by either the flume or towing method should give acceptable results.
COMPARISON OF INTEGRATED SAMPLERS FOR MASS AND COMPOSITION
The primary objective of EPA's Atlanta Supersites Project was to compare and evaluate a wide variety of samplers from time-integrated mass only monitors, to integrated and semi-continuous chemical speciation samplers, to single particle mass spectrometers. This paper will desc...
Objectives. This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Approach/Activities. Fifty-five studies were found where both passive sampler uptake...
Selecting Performance Reference Compounds (PRCS) for Low Density Polyethylene Passive Samplers
Use of equilibrium passive samplers for performing aquatic environmental monitoring at contaminated sites is becoming more common. However, a current challenge in passive sampling is determining when equilibrium is achieved between the sampler, target contaminants, and environm...
Proteome changes in platelets after pathogen inactivation--an interlaboratory consensus.
Prudent, Michel; D'Alessandro, Angelo; Cazenave, Jean-Pierre; Devine, Dana V; Gachet, Christian; Greinacher, Andreas; Lion, Niels; Schubert, Peter; Steil, Leif; Thiele, Thomas; Tissot, Jean-Daniel; Völker, Uwe; Zolla, Lello
2014-04-01
Pathogen inactivation (PI) of platelet concentrates (PCs) reduces the proliferation/replication of a large range of bacteria, viruses, and parasites as well as residual leucocytes. Pathogen-inactivated PCs were evaluated in various clinical trials showing their efficacy and safety. Today, there is some debate over the hemostatic activity of treated PCs as the overall survival of PI platelets seems to be somewhat reduced, and in vitro measurements have identified some alterations in platelet function. Although the specific lesions resulting from PI of PCs are still not fully understood, proteomic studies have revealed potential damages at the protein level. This review merges the key findings of the proteomic analyses of PCs treated by the Mirasol Pathogen Reduction Technology, the Intercept Blood System, and the Theraflex UV-C system, respectively, and discusses the potential impact on the biological functions of platelets. The complementarities of the applied proteomic approaches allow the coverage of a wide range of proteins and provide a comprehensive overview of PI-mediated protein damage. It emerges that there is a relatively weak impact of PI on the overall proteome of platelets. However, some data show that the different PI treatments lead to an acceleration of platelet storage lesions, which is in agreement with the current model of platelet storage lesion in pathogen-inactivated PCs. Overall, the impact of the PI treatment on the proteome appears to be different among the PI systems. Mirasol impacts adhesion and platelet shape change, whereas Intercept seems to impact proteins of intracellular platelet activation pathways. Theraflex influences platelet shape change and aggregation, but the data reported to date are limited. This information provides the basis to understand the impact of different PI on the molecular mechanisms of platelet function. Moreover, these data may serve as basis for future developments of PI technologies for PCs. Further studies should address the impact of both the PI and the storage duration on platelets in PCs because PI may enable the extension of the shelf life of PCs by reducing the bacterial contamination risk. Copyright © 2014 Elsevier Inc. All rights reserved.
Obeid, Sara; Fanning, Alex
2017-01-01
Introduction: To date, there have been few studies in the field of plastic surgery examining the knowledge, attitudes, and behavior of educators and residents regarding diversity and inclusion, especially for the purposes of enhancing resident education, improving diversity efforts, and addressing health care disparities. Methods: An anonymous survey was provided electronically to a total of 462 American Council of Academic Plastic Surgeon members and 91 program coordinators (PCs), and 1,029 plastic surgery residents at 91 institutions across the United States. We analyzed the responses from PCs and program directors (PDs). Results: We collected responses from 34 institutions (37%), and 16.8% of American Council of Academic Plastic Surgeon members including 34 PCs and 44 PDs. We found that PDs were more likely to be male (86%) and above the age of 40 years (97%) compared with PCs (5% male and 61% above 40 years). Both groups were majority White. Fifty-nine percentage of PDs have a parent/guardian who attained a graduate degree versus 15% of PCs. Forty-eight percentage of PDs speak another language compared with 16% of PCs. More importantly, 95% of PDs had an opportunity to engage in diversity and inclusion-related activities in the last 6 months as compared with 43% of PCs; however, we did not find a statistical difference based on knowledge of increasing institutional capacity of diversity and inclusion between the 2 groups. PCs were more likely to witness discrimination (64%) than PDs (40%) in the health care setting, with body type/weight emerging as the most common type of discrimination. Very few respondents (10%) indicated they discriminated against others. Conclusions: Plastic surgery educators are committed to diversity and inclusion. Improvements can be made by incorporating PCs more frequently in activities related to the topic along with focused training on improving diversity on an institutional rather than individual level. Our study suggests body type/weight is the most common type of discrimination witnessed by the entire cohort and that diversity and inclusion remains a sensitive topic.
Fully automated processing of buffy-coat-derived pooled platelet concentrates.
Janetzko, Karin; Klüter, Harald; van Waeg, Geert; Eichler, Hermann
2004-07-01
The OrbiSac device, which was developed to automate the manufacture of buffy-coat PLT concentrates (BC-PCs), was evaluated. In-vitro characteristics of BC-PC preparations using the OrbiSac device were compared with manually prepared BC-PCs. For standard processing (Std-PC, n = 20), four BC-PCs were pooled using 300 mL of PLT AS (PAS) followed by soft-spin centrifugation and WBC filtration. The OrbiSac preparation (OS-PC, n = 20) was performed by automated pooling of four BC-PCs with 300 mL PAS followed by centrifugation and inline WBC filtration. All PCs were stored at 22 degrees C. Samples were withdrawn on Day 1, 5, and 7 evaluating PTL count, blood gas analysis, glucose, lactate, LDH, beta-thromboglobulin, hypotonic shock response, and CD62p expression. A PLT content of 3.1 +/- 0.4 x 10(11) (OS-PCs) versus 2.7 +/- 0.5 x 10(11) (Std-PCs, p < 0.05) was found. A CV of 19 percent (Std-PC) versus 14 percent (OS-PC) suggests more standardization in the OS group. At Day 7, the Std-PCs versus OS-PCs showed a glucose consumption of 1.03 +/- 0.32 micro mol per 10(9) PLT versus 0.75 +/- 0.25 micro mol per 10(9) PLT (p < 0.001), and a lactate production of 1.50 +/- 0.86 micro mol per 10(9) versus 1.11 +/- 0.61 micro mol per 10(9) (p < 0.001). The pH (7.00 +/- 0.19 vs. 7.23 +/- 0.06; p < 0.001), pO(2) (45.3 +/- 18 vs. 31.3 +/- 10.4 mmHg; p < 0.01), and HCO(3) levels (4.91 +/- 1.49 vs. 7.14 +/- 0.95 mmol/L; p < 0.001) suggest a slightly better aerobic metabolism within the OS group. Only small differences in CD62p expression was observed (37.3 +/- 12.9% Std-PC vs. 44.8 +/- 6.6% OS-PC; p < 0.05). The OrbiSac device allows an improved PLT yield without affecting PLT in-vitro characteristics and may enable an improved consistency in product volume and yield.
Premorbid IQ Predicts Postconcussive Symptoms in OEF/OIF/OND Veterans with mTBI.
Stewart-Willis, Jada J; Heyanka, Daniel; Proctor-Weber, Zoe; England, Heather; Bruhns, Maya
2018-03-01
Extant literature has demonstrated that symptoms of postconcussive syndrome (PCS) persist well beyond the expected 3-month post-injury recovery period in a minority of individuals with mild traumatic brain injury (mTBI). Suboptimal performance on validity measures and pre- and post-injury psychosocial stressors - rather than actual mTBI or current cognitive functioning - have been identified as predictors of chronic PCS. Whether premorbid IQ has any influence on chronic PCS has been understudied, in the context of established psychogenic etiologies. The sample included 31 veterans, who underwent mTBI neuropsychological evaluations six or more months post-injury in a VA outpatient neuropsychology clinic. A two-step multiple linear regression was conducted to examine the effects on the outcome variable, PCS (Neurobehavioral Symptom Inventory), of the following predictors: cognitive functioning (Repeatable Battery for the Assessment of Neuropsychological Status; Attention, Immediate Memory, and Delayed Memory Indices), performance validity, depression (Beck Depression Inventory-Second Edition), posttraumatic stress disorder (PTSD Checklist, Civilian Version), quality of sleep (Pittsburgh Sleep Quality Index), pain (Brief Pain Inventory), education, and Premorbid IQ (Wechsler Test of Adult Reading). The overall regression model containing all nine predictor variables was statistically significant. Depression (p < .05) and premorbid IQ (p < .05) were the most salient predictors of chronic PCS; in that lower premorbid IQ and greater endorsed symptoms of depression were associated with higher PCS scores. In Step 2 of the multiple linear regression, the WTAR explained an additional 6.7% of the variance in PCS after controlling for psychosocial stressors and current cognitive ability. The findings support premorbid IQ as a unique and relevant predictor of chronic PCS, with significance variance accounted for beyond education, cognitive functioning, and psychosocial variables. Given the predictive relationship between premorbid IQ and PCS, adapting postconcussive interventions to meet the specific needs of individuals with varying levels of intellect may be important in minimizing ongoing symptomatology. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Khan, Md Firoz; Latif, Mohd Talib; Amil, Norhaniza; Juneng, Liew; Mohamad, Noorlin; Nadzir, Mohd Shahrul Mohd; Hoque, Hossain Mohammed Syedul
2015-09-01
Principal component analysis (PCA) and correlation have been used to study the variability of particle mass and particle number concentrations (PNC) in a tropical semi-urban environment. PNC and mass concentration (diameter in the range of 0.25->32.0 μm) have been measured from 1 February to 26 February 2013 using an in situ Grimm aerosol sampler. We found that the 24-h average total suspended particulates (TSP), particulate matter ≤10 μm (PM10), particulate matter ≤2.5 μm (PM2.5) and particulate matter ≤1 μm (PM1) were 14.37 ± 4.43, 14.11 ± 4.39, 12.53 ± 4.13 and 10.53 ± 3.98 μg m(-3), respectively. PNC in the accumulation mode (<500 nm) was the most abundant (at about 99 %). Five principal components (PCs) resulted from the PCA analysis where PC1 (43.8 % variance) predominates with PNC in the fine and sub-microme tre range. PC2, PC3, PC4 and PC5 explain 16.5, 12.4, 6.0 and 5.6 % of the variance to address the coarse, coarser, accumulation and giant fraction of PNC, respectively. Our particle distribution results show good agreement with the moderate resolution imaging spectroradiometer (MODIS) distribution.
Wang, Lei; Gong, Xinying; Wang, Ruonan; Gan, Zhiwei; Lu, Yuan; Sun, Hongwen
2017-09-15
Ionic liquids have been used to efficiently extract a wide range of polar and nonpolar organic contaminants from water. In this study, imidazole ionic liquids immobilized on silica gel were synthesized through a chemical bonding method, and the immobilized dodecylimidazolium ionic liquid was selected as the receiving phase material in a POCIS (polar organic chemical integrative sampler) like passive sampler to monitor five perfluoroalkyl substances (PFASs) in water. Twenty-one days of integrative accumulation was conducted in laboratory scale experiments, and the accumulated PFASs in the samplers were eluted and analyzed by high performance liquid chromatography coupled with tandem mass spectrometry (HPLC-MS/MS). The partitioning coefficients of most PFASs between sampler sorbents and water in the immobilized ionic liquid (IIL)-sampler were higher than those in the HLB-sampler, especially for compounds with shorter alkyl chains. The effects of flow velocity, temperature, dissolved organic matter (DOM) and pH on the uptake of these analytes were also evaluated. Under the experimental conditions, the uptake of PFASs in the IIL-sampler slightly increased with the flow velocity and temperature, while different influences of DOM and pH on the uptake of PFAS homologues with short or long chains were observed. The designed IIL-samplers were applied in the influent and effluent of a wastewater treatment plant. All five PFASs could be accumulated in the samplers, with concentrations ranging from 6.5×10 -3 -3.6×10 -1 nmol/L in the influent and from 1.3×10 -2 -2.2×10 -1 nmol/L in the effluent. The calculated time-weighted average concentrations of most PFASs fit well with the detected concentrations of the active sampling, indicating the applicability of the IIL-sampler in monitoring these compounds in water. Copyright © 2017 Elsevier B.V. All rights reserved.
Numerical Evaluation of Lateral Diffusion Inside Diffusive Gradients in Thin Films Samplers
2015-01-01
Using numerical simulation of diffusion inside diffusive gradients in thin films (DGT) samplers, we show that the effect of lateral diffusion inside the sampler on the solute flux into the sampler is a nonlinear function of the diffusion layer thickness and the physical sampling window size. In contrast, earlier work concluded that this effect was constant irrespective of parameters of the sampler geometry. The flux increase caused by lateral diffusion inside the sampler was determined to be ∼8.8% for standard samplers, which is considerably lower than the previous estimate of ∼20%. Lateral diffusion is also propagated to the diffusive boundary layer (DBL), where it leads to a slightly stronger decrease in the mass uptake than suggested by the common 1D diffusion model that is applied for evaluating DGT results. We introduce a simple correction procedure for lateral diffusion and demonstrate how the effect of lateral diffusion on diffusion in the DBL can be accounted for. These corrections often result in better estimates of the DBL thickness (δ) and the DGT-measured concentration than earlier approaches and will contribute to more accurate concentration measurements in solute monitoring in waters. PMID:25877251
NASA Astrophysics Data System (ADS)
van Rossum, Anne C.; Lin, Hai Xiang; Dubbeldam, Johan; van der Herik, H. Jaap
2018-04-01
In machine vision typical heuristic methods to extract parameterized objects out of raw data points are the Hough transform and RANSAC. Bayesian models carry the promise to optimally extract such parameterized objects given a correct definition of the model and the type of noise at hand. A category of solvers for Bayesian models are Markov chain Monte Carlo methods. Naive implementations of MCMC methods suffer from slow convergence in machine vision due to the complexity of the parameter space. Towards this blocked Gibbs and split-merge samplers have been developed that assign multiple data points to clusters at once. In this paper we introduce a new split-merge sampler, the triadic split-merge sampler, that perform steps between two and three randomly chosen clusters. This has two advantages. First, it reduces the asymmetry between the split and merge steps. Second, it is able to propose a new cluster that is composed out of data points from two different clusters. Both advantages speed up convergence which we demonstrate on a line extraction problem. We show that the triadic split-merge sampler outperforms the conventional split-merge sampler. Although this new MCMC sampler is demonstrated in this machine vision context, its application extend to the very general domain of statistical inference.
Passive samplers are used to measure dissolved nonionic organic contaminants (NOCs) in environmental media. More recently, reverse polyethylene samplers (RePES) have been used with spiked sediments to recreate interstitial water exposure concentrations and observed toxicity. In...
This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Fifty-four studies were found where both passive sampler uptake and organism bioaccumulation wer...
Determining Passive Sampler Partition Coefficients for Dissolved-phase Organic Contaminants
Passive samplers are used for environmental and analytical purposes to measure dissolved nonionic organic contaminants (NOCs) by absorption from a contaminated medium into a clean phase, usually in the form of a synthetic organic film. Recently developed passive sampler techniqu...
This Critcal Review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) in water column and interstitial water exposures as a surrogate for organism bioaccumulation. Fifty-seven studies were found where both passive sampler uptake and organism bioaccumulat...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, Steve E.
The accuracy and precision of a new Isolok sampler configuration was evaluated using a recirculation flow loop. The evaluation was performed using two slurry simulants of Hanford high-level tank waste. Through testing, the capability of the Isolok sampler was evaluated. Sample concentrations were compared to reference samples that were simultaneously collected by a two-stage Vezin sampler. The capability of the Isolok sampler to collect samples that accurately reflect the contents in the test loop improved – biases between the Isolok and Vezin samples were greatly reduce for fast settling particles.
Evaluation of the Snap Sampler for Sampling Ground Water Monitoring Wells for Inorganic Analytes
2008-12-01
08-25 3 Accumulation samplers rely on both diffusion through a membrane and then sorption by some type of sorbent material that is contained in the...the materials in the sampler to equilibrate with the analytes in the well water thereby prevent- ing losses of analytes due to sorption by the sampler...The spring in the bottles is coated with perfluoroalkoxy ( PFA ) (Teflon) and is connected to PFA end caps at both ends of the bottle. Currently
McEwan, Thomas E.
1994-01-01
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, .+-.UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals.
McEwan, Thomas E.
1996-01-01
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, .+-.UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals.
Lyford, F.P.; Kliever, J.D.; Scott, Clifford
1999-01-01
Volatile organic compounds are present in ground water at the Allen Harbor Landfill and the Calf Pasture Point sites on the former Naval Construction Battalion Center in Davisville, R.I. Vapor-diffusion samplers were used at the two sites during March-April 1998 to identify possible discharge points for contaminants along the shore of Allen Harbor and in two wetland areas near the shore. Results from vapor-diffusion samplers will be used in conjunction with other site information to evaluate proposed ground-water monitoring programs. Volatile organic compounds were detected in 41 of 115 samplers placed along the shoreline at the Allen Harbor Landfill. Trichloroethylene was the principal volatile organic compound detected of eight target compounds. The highest vapor concentration measured exceeded 300,000 parts per billion by volume in an area where TCE was detected in groundwater from nearby monitoring wells. Other chemicals detected in vapor-diffusion samplers included tetrachloroethylene, toluene, and benzene. Concentrations of individual volatile organic compounds were less than 100 parts per billion by volume in most samplers. Volatile organic compounds, principally trichloroethylene, were detected in 7 of 30 samplers placed along the shoreline at Calf Pasture Point; the highest trichloroethylene concentration was 1,900 parts per billion by volume. A trace concentration of tetrachloroethylene was detected in one of the samplers. One of 24 samplers placed in two wetland areas near the shore (suspected discharge areas for ground-water containing volatile organic compounds) detected trichloroethylene at a vapor concentration of 14 parts per billion by volume.
Evaluation of a novel personal nanoparticle sampler.
Zhou, Yue; Irshad, Hammad; Tsai, Chuen-Jinn; Hung, Shao-Ming; Cheng, Yung-Sung
2014-02-01
This work investigated the performance in terms of collection efficiency and aspiration efficiency of a personal sampler capable of collecting ultrafine particles (nanoparticles) in the occupational environment. This sampler consists of a cyclone for respirable particle classification, micro-orifice impactor stages with an acceleration nozzle to achieve nanoparticle classification and a backup filter to collect nanoparticles. Collection efficiencies of the cyclone and impactor stages were determined using monodisperse polystyrene latex and silver particles, respectively. Calibration of the cyclone and impactor stages showed 50% cut-off diameters of 3.95 μm and 94.7 nm meeting the design requirements. Aspiration efficiencies of the sampler were tested in a wind tunnel with wind speeds of 0.5, 1.0, and 1.5 m s(-1). The test samplers were mounted on a full size mannequin with three orientations toward the wind direction (0°, 90°, and 180°). Monodisperse oleic acid aerosols tagged with sodium fluorescein in the size range of 2 to 10 μm were used in the test. For particles smaller than 2 μm, the fluorescent polystyrene latex particles were generated by using nebulizers. For comparison of the aspiration efficiency, a NIOSH two-stage personal bioaerosol sampler was also tested. Results showed that the orientation-averaged aspiration efficiency for both samplers was close to the inhalable fraction curve. However, the direction of wind strongly affected the aspiration efficiency. The results also showed that the aspiration efficiency was not affected by the ratio of free-stream velocity to the velocity through the sampler orifice. Our evaluation showed that the current design of the personal sampler met the designed criteria for collecting nanoparticles ≤100 nm in occupational environments.
NASA Astrophysics Data System (ADS)
Trakumas, S.; Salter, E.
2009-02-01
Adverse health effects due to exposure to airborne particles are associated with particle deposition within the human respiratory tract. Particle size, shape, chemical composition, and the individual physiological characteristics of each person determine to what depth inhaled particles may penetrate and deposit within the respiratory tract. Various particle inertial classification devices are available to fractionate airborne particles according to their aerodynamic size to approximate particle penetration through the human respiratory tract. Cyclones are most often used to sample thoracic or respirable fractions of inhaled particles. Extensive studies of different cyclonic samplers have shown, however, that the sampling characteristics of cyclones do not follow the entire selected convention accurately. In the search for a more accurate way to assess worker exposure to different fractions of inhaled dust, a novel sampler comprising several inertial impactors arranged in parallel was designed and tested. The new design includes a number of separated impactors arranged in parallel. Prototypes of respirable and thoracic samplers each comprising four impactors arranged in parallel were manufactured and tested. Results indicated that the prototype samplers followed closely the penetration characteristics for which they were designed. The new samplers were found to perform similarly for liquid and solid test particles; penetration characteristics remained unchanged even after prolonged exposure to coal mine dust at high concentration. The new parallel impactor design can be applied to approximate any monotonically decreasing penetration curve at a selected flow rate. Personal-size samplers that operate at a few L/min as well as area samplers that operate at higher flow rates can be made based on the suggested design. Performance of such samplers can be predicted with high accuracy employing well-established impaction theory.
Field comparison of three inhalable samplers (IOM, PGP-GSP 3.5 and Button) for welding fumes.
Zugasti, Agurtzane; Montes, Natividad; Rojo, José M; Quintana, M José
2012-02-01
Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.
1979-06-01
wf ’U ~ ~ ~ a~ 77-1 . M. , .16. O~lAIL OP OF OMAft TO SLW-F PIPE~LCCABE O i O-FFi I - - - SCALL CA ri.w -0p -" ~4bb .Aw 15CSCAL l1.4d .4* 4o %R*a...11’ sia !e, Massac.husettsNX FFE 6H,..NO RATEF, c. 3VA’l 7a tAS NO SAMPLER CORE BAR. ms - T FT AFrH... HS TagL SS NC A TE 1___ 9/1G,_____7c__ -. 1
Dillon, Stephanie L; Williamson, Danielle M; Elferich, Johannes; Radler, David; Joshi, Rajendra; Thomas, Gary; Shinde, Ujwal
2012-10-12
The proprotein convertases (PCs) furin and proprotein convertase 1/3 (PC1) cleave substrates at dibasic residues along the eukaryotic secretory/endocytic pathway. PCs are evolutionarily related to bacterial subtilisin and are synthesized as zymogens. They contain N-terminal propeptides (PRO) that function as dedicated catalysts that facilitate folding and regulate activation of cognate proteases through multiple-ordered cleavages. Previous studies identified a histidine residue (His69) that functions as a pH sensor in the propeptide of furin (PRO(FUR)), which regulates furin activation at pH~6.5 within the trans-Golgi network. Although this residue is conserved in the PC1 propeptide (PRO(PC1)), PC1 nonetheless activates at pH~5.5 within the dense core secretory granules. Here, we analyze the mechanism by which PRO(FUR) regulates furin activation and examine why PRO(FUR) and PRO(PC1) differ in their pH-dependent activation. Sequence analyses establish that while both PRO(FUR) and PRO(PC1) are enriched in histidines when compared with cognate catalytic domains and prokaryotic orthologs, histidine content in PRO(FUR) is ~2-fold greater than that in PRO(PC1), which may augment its pH sensitivity. Spectroscopy and molecular dynamics establish that histidine protonation significantly unfolds PRO(FUR) when compared to PRO(PC1) to enhance autoproteolysis. We further demonstrate that PRO(FUR) and PRO(PC1) are sufficient to confer organelle sensing on folding and activation of their cognate proteases. Swapping propeptides between furin and PC1 transfers pH-dependent protease activation in a propeptide-dictated manner in vitro and in cells. Since prokaryotes lack organelles and eukaryotic PCs evolved from propeptide-dependent, not propeptide-independent prokaryotic subtilases, our results suggest that histidine enrichment may have enabled propeptides to evolve to exploit pH gradients to activate within specific organelles. Copyright © 2012 Elsevier Ltd. All rights reserved.
Far-infrared tangential interferometer/polarimeter design and installation for NSTX-U
Scott, E. R.; Barchfeld, R.; Riemenschneider, P.; ...
2016-08-09
Here, the Far-infrared Tangential Interferometer/Polarimeter (FIReTIP) system has been refurbished and is being reinstalled on the National Spherical Torus Experiment—Upgrade (NSTX-U) to supply real-time line-integrated core electron density measurements for use in the NSTX-U plasma control system (PCS) to facilitate real-time density feedback control of the NSTX-U plasma. Inclusion of a visible light heterodyne interferometer in the FIReTIP system allows for real-time vibration compensation due to movement of an internally mounted retroreflector and the FIReTIP front-end optics. Real-time signal correction is achieved through use of a National Instruments CompactRIO field-programmable gate array.
Grossberger, Amnon; Hadar, Yitzhak; Borch, Thomas; Chefetz, Benny
2014-02-01
Pharmaceutical compounds (PCs) are introduced into agricultural soils via irrigation with treated wastewater (TWW). Our data show that carbamazepine, lamotrigine, caffeine, metoprolol, sulfamethoxazole and sildenafil are persistent in soils when introduced via TWW. However, other PCs, namely diclofenac, ibuprofen, bezafibrate, gemfibrozil and naproxen were not detected in soils when introduced via TWW. This is likely due to rapid degradation as confirmed in our microcosm studies where they exhibited half-lives (t1/2) between 0.2-9.5 days when soils were spiked at 50 ng/g soil and between 3 and 68 days when soils were spiked at 5000 ng/g soil. The degradation rate and extent of PCs observed in microcosm studies were similar in soils that had been previously irrigated with TWW or fresh water. This suggests that pre-exposure of the soils to PCs via irrigation with TWW does not enhance their biodegradation. This suggests that PCs are probably degraded in soils via co-metabolism. Copyright © 2013 Elsevier Ltd. All rights reserved.
Exploring the use of tablet PCs in veterinary medical education: opportunity or obstacle?
Wang, Hong; Rush, Bonnie R; Wilkerson, Melinda; van der Merwe, Deon
2014-01-01
A tablet PC is a laptop computer with a touch screen and a digital pen or stylus that can be used for handwritten notes and drawings. The use of tablet PCs has been investigated in many disciplines such as engineering, mathematics, science, and education. The purpose of this article is to explore student and faculty attitudes toward and experiences with tablet PCs 6 years after the implementation of a tablet PC program in the College of Veterinary Medicine (CVM) at Kansas State University (K-State). This study reports that the use of tablet PCs has enhanced students' learning experiences through learner-interface interaction, learner-content interaction, learner-instructor interaction, and learner-learner interaction. This study also identifies digital distraction as the major negative experience with tablet PCs during class time. The tablet PC program provides CVM faculty the potential to pursue technology integration strategies that support expected learning outcomes and provides students the potential to develop self-monitoring and self-discipline skills that support learning with digital technologies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Afzal, Muhammad U., E-mail: muhammad.afzal@mq.edu.au; Esselle, Karu P.
This paper presents a quasi-analytical technique to design a continuous, all-dielectric phase correcting structures (PCSs) for circularly polarized Fabry-Perot resonator antennas (FPRAs). The PCS has been realized by varying the thickness of a rotationally symmetric dielectric block placed above the antenna. A global analytical expression is derived for the PCS thickness profile, which is required to achieve nearly uniform phase distribution at the output of the PCS, despite the non-uniform phase distribution at its input. An alternative piecewise technique based on spline interpolation is also explored to design a PCS. It is shown from both far- and near-field results thatmore » a PCS tremendously improves the radiation performance of the FPRA. These improvements include an increase in peak directivity from 22 to 120 (from 13.4 dBic to 20.8 dBic) and a decrease of 3 dB beamwidth from 41.5° to 15°. The phase-corrected antenna also has a good directivity bandwidth of 1.3 GHz, which is 11% of the center frequency.« less
Tissue Distribution Of Chloroaluminium Sulfonated Phthalocyanine In Dogs
NASA Astrophysics Data System (ADS)
M. M.; H. C.; Newman
1989-06-01
Chloroaluminum sulfonated phthalocyanine (A1PCS) was administered intravenously to clinically normal dogs, and A1PCS levels were determined in tissues using a sensitive assay. A1PCS accumulated to high levels in liver, spleen, bone marrow, kidney, and lung. These tissue levels confirm previous determinations in mice and rats. Only a small amount of dye was retained in skin and very small amounts in muscle and brain. A1PCS was cleared from the blood within 24 h, and excreted primarily by urine. Serum clearance was faster in males than in females. There were also significant tissue distribution differences between the genders, particularly during the first 12 h. The low levels of A1PCS in skin suggest that cutaneous photosensitivity and toxic skin reactions using this photosensitizer in photodynamic therapy of cancer may be eliminated. The difference in tissue distribution between genders is not only intriguing, but indicates that the optimal time window for treatment of various tissue sites may vary by gender.
Consumer-directed models of personal care: lessons from Medicaid.
Doty, P; Kasper, J; Litvak, S
1996-01-01
"Consumer-directed" models of financing and services delivery are compared with models that emphasize professional control and accountability within the context of Medicaid-financed personal care services (PCS). The Medicaid PCS benefit finances aide or attendant services for low-income persons with functional disabilities to assist them with daily living tasks. Consumer-directed modes of service provision permit service recipients themselves to have greater choice and control over all aspects of service provision. Client surveys in three states found that clients were most satisfied with the program elements of Medicaid PCS services that gave them more choice and control. Case studies of how Medicaid PCS programs in particular states are administered indicate that the use of aides who are independent providers, unattached to a home health or home care agency, is a critical aspect of consumer direction. By itself, however, this factor does not guarantee consumer direction because other Medicaid PCS rules and regulations may restrict client choice and control.
Guidelines for Using Passive Samplers to Monitor Organic Contaminants at Superfund Sediment Sites
Passive samplers are monitoring tools that can provide faster, cheaper, and scientifically-sound information about the water column and interstitial water concentrations of contaminants of concern (COC) at Superfund sites. Often, the use of passive samplers is more effective tha...
This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) as it relates to organism bioaccumulation in the water column and interstitial water. Fifty-five studies were found where both passive samplers and organism bioaccumulation were used to measur...
Construction and testing of a simple and economical soil greenhouse gas automatic sampler
Ginting, D.; Arnold, S.L.; Arnold, N.S.; Tubbs, R.S.
2007-01-01
Quantification of soil greenhouse gas emissions requires considerable sampling to account for spatial and/or temporal variation. With manual sampling, additional personnel are often not available to sample multiple sites within a narrow time interval. The objectives were to construct an automatic gas sampler and to compare the accuracy and precision of automatic versus manual sampling. The automatic sampler was tested with carbon dioxide (CO2) fluxes that mimicked the range of CO2 fluxes during a typical corn-growing season in eastern Nebraska. Gas samples were drawn from the chamber at 0, 5, and 10 min manually and with the automatic sampler. The three samples drawn with the automatic sampler were transferred to pre-vacuumed vials after 1 h; thus the samples in syringe barrels stayed connected with the increasing CO2 concentration in the chamber. The automatic sampler sustains accuracy and precision in greenhouse gas sampling while improving time efficiency and reducing labor stress. Copyright ?? Taylor & Francis Group, LLC.
Apell, Jennifer N; Tcaciuc, A Patricia; Gschwend, Philip M
2016-07-01
Polymeric passive samplers have become a common method for estimating freely dissolved concentrations in environmental media. However, this approach has not yet been adopted by investigators conducting remedial investigations of contaminated environmental sites. Successful adoption of this sampling methodology relies on an understanding of how passive samplers accumulate chemical mass as well as developing guidance for the design and deployment of passive samplers. Herein, we outline the development of a simple mathematical relationship of the environmental, polymer, and chemical properties that control the uptake rate. This relationship, called a timescale, is then used to illustrate how each property controls the rate of equilibration in samplers deployed in the water or in the sediment. Guidance is also given on how to use the timescales to select an appropriate polymer, deployment time, and suite of performance reference compounds. Integr Environ Assess Manag 2016;12:486-492. © 2015 SETAC. © 2015 SETAC.
Evaluation of passive samplers for the collection of dissolved organic matter in streams.
Warner, Daniel L; Oviedo-Vargas, Diana; Royer, Todd V
2015-01-01
Traditional sampling methods for dissolved organic matter (DOM) in streams limit opportunities for long-term studies due to time and cost constraints. Passive DOM samplers were constructed following a design proposed previously which utilizes diethylaminoethyl (DEAE) cellulose as a sampling medium, and they were deployed throughout a temperate stream network in Indiana. Two deployments of the passive samplers were conducted, during which grab samples were frequently collected for comparison. Differences in DOM quality between sites and sampling methods were assessed using several common optical analyses. The analyses revealed significant differences in optical properties between sampling methods, with the passive samplers preferentially collecting terrestrial, humic-like DOM. We assert that the differences in DOM composition from each sampling method were caused by preferential binding of complex humic compounds to the DEAE cellulose in the passive samplers. Nonetheless, the passive samplers may provide a cost-effective, integrated sample of DOM in situations where the bulk DOM pool is composed mainly of terrestrial, humic-like compounds.
Wu, Xian-chuang; Du, Gang-jun; Song, Xiao-yong; Zhang, Yong-zhou; Liu, Yu-xin
2014-10-01
To study the protective effect of polysaccharides from corn silk (PCS) against cyclophosphamide (CTX) induced host damages in mice bearing H22 tumors. The ascitic and solid tumor bearing mice model were established to investigate the anti-tumor effects of different dose of PCS (100, 200 and 300 mg/kg). The effects of PCS alone and with combination of CTX on tumor weight, survival time, thymus and spleen index, white blood cell, nucleated cell of marrow, serum ALT and AST level were tested. The high-dose PCS (300 mg/kg) had significant inhibitory effects on tumor. After combination with CTX, the tumor inhibitory ratio was enhanced to 68.71%, the survival time of tumor-burdened ascites tumor mice was significantly prolonged to 72.07% compared with CTX group. The Q value of combination group was 0.997. Thymus and spleen index, white blood cell, nucleated cell of marrow decreased by CTX were ameliorated significantly. The level of ALT and AST increased by CTX were reduced by combination with PCS. PCS has a potent inhibitory effect on the growth of implanted H22 tumors in mice and has a synergetic effect and an attenuated toxic effect in combination with CTX.
Liu, Ting; Ren, Jun; Wang, Wei; Wei, Xia-wei; Shen, Guo-bo; Liu, Yan-tong; Luo, Min; Xu, Guang-chao; Shao, Bin; Deng, Sen-yi; He, Zhi-yao; Liang, Xiao; Liu, Yu; Wen, Yan-Zhu; Xiang, Rong; Yang, Li; Deng, Hong-xin; Wei, Yu-quan
2015-01-01
The adoptive transfer of the natural regulatory B cells and macrophages should be a useful treatment for inflammation and autoimmune disease. However, it is usually difficult to isolate these cells from the tissues and expand them. Here, we investigated the feasibility of adoptively transferring peritoneal cells (PCs) as a treatment for DSS-induced colitis. We found that peritoneal cavity can provide an easily accessible site for harvesting enough number of PCs, namely, two-dose PCs for the treatment from a mouse in one operation. Adoptive therapy of these cells from healthy mice or those with disease is effectively in reducing the disease activity score. The natural B cells and macrophages of the infused PCs can selectively migrate to lesion sites and regulate the expression of Stat3, NF−κB, Smad3 and Smad7. Additionally, PCs exert dual activity of IL-10 and TGF-β secreted spontaneously by both peritoneal B cells and macrophages, which in turn enhance the induction of regulatory B cells and Macrophages in microenvironment of inflammation. Moreover, PCs can re-establish immunological tolerance in the OVA-immunized mice. Thus, our findings provide a new strategy for colitis therapy and could be of importance in additional exploration of other inflammation and autoimmune diseases therapy. PMID:26565726
Poplar maintains zinc homeostasis with heavy metal genes HMA4 and PCS1
Adams, Joshua P.; Adeli, Ardeshir; Hsu, Chuan-Yu; Harkess, Richard L.; Page, Grier P.; dePamphilis, Claude W.; Schultz, Emily B.; Yuceer, Cetin
2011-01-01
Perennial woody species, such as poplar (Populus spp.) must acquire necessary heavy metals like zinc (Zn) while avoiding potential toxicity. Poplar contains genes with sequence homology to genes HMA4 and PCS1 from other species which are involved in heavy metal regulation. While basic genomic conservation exists, poplar does not have a hyperaccumulating phenotype. Poplar has a common indicator phenotype in which heavy metal accumulation is proportional to environmental concentrations but excesses are prevented. Phenotype is partly affected by regulation of HMA4 and PCS1 transcriptional abundance. Wild-type poplar down-regulates several transcripts in its Zn-interacting pathway at high Zn levels. Also, overexpressed PtHMA4 and PtPCS1 genes result in varying Zn phenotypes in poplar; specifically, there is a doubling of Zn accumulation in leaf tissues in an overexpressed PtPCS1 line. The genomic complement and regulation of poplar highlighted in this study supports a role of HMA4 and PCS1 in Zn regulation dictating its phenotype. These genes can be altered in poplar to change its interaction with Zn. However, other poplar genes in the surrounding pathway may maintain the phenotype by inhibiting drastic changes in heavy metal accumulation with a single gene transformation. PMID:21504875
Miller, Douglas L.; Dou, Chunyan; Lucchesi, Benedict R.
2009-01-01
Objective Premature complexes (PCs) in the electrocardiogram (ECG) signal have been reported for myocardial contrast echocardiography and also for burst mode (physical therapy) ultrasound with gas body contrast agent at lower peak rarefactional pressure amplitudes (PRPAs). For contrast echocardiography, irreversibly injured cardiomyocytes have been associated with the arrhythmia. The objective was to determine if cardiomyocyte injury is associated with the PCs induced by the burst mode at lower PRPAs. Methods Anesthetized rats were exposed to focused 1.5 MHz ultrasound in a water bath. Evans blue dye was injected IP to stain injured cardiomyocytes and Definity ultrasound contrast agent was infused IV. Continuous burst mode simulated physical therapy ultrasound. Intermittent 2 ms bursts, or envelopes of pulses simulating diagnostic ultrasound, were triggered 1:4 at end systole. PCs were observed on ECG recordings and stained cardiomyocytes were counted in frozen sections. Results The continuous burst mode produced variable PCs and stained cells above 0.3 MPa PRPA. The triggered bursts above 0.3 MPa and pulse envelopes above 1.2 MPa produced statistically significant (P<0.01) PCs and stained cardiomyocytes. Conclusion Irreversible cardiomyocyte injury was associated with the development of PCs for burst mode and occurred at substantially lower PRPAs than for pulsed ultrasound. PMID:19854967
Role of cytosolic calcium diffusion in cardiac purkinje cells.
Limbu, Bijay; Shah, Kushal; Deo, Makarand
2016-08-01
The Cardiac Purkinje cells (PCs) exhibit distinct calcium (Ca2+) homeostasis than that in ventricular myocytes (VMs). Due to lack of t-tubules in PCs, the Ca2+ ions entering the cell have to diffuse through the cytoplasm to reach the sarcoplasmic reticulum (SR) before triggering Ca2+-induced-Ca2+-release (CICR). In recent experimental studies PCs have been shown to be more susceptible to action potential (AP) abnormalities than the VMs, however the exact mechanisms are poorly understood. In this study, we utilize morphologically realistic detailed biophysical mathematical model of a murine PC to systematically examine the role intracellular Ca2+ diffusion in the APs of PCs. A biphasic spatiotemporal Ca2+ diffusion process, as observed experimentally, was implemented in the model which includes radial Ca2+ wavelets and cell wide longitudinal Ca2+ diffusion wave (CWW). The AP morphology, specifically plateau, is affected due to changes in intracellular Ca2+ dynamics. When Ca2+ concentration in sarcolemmal region is elevated, it activated inward sodium Ca2+ exchanger (NCX) current resulting into prolongation of the plateau at faster diffusion rates. Our results demonstrate that the cytosolic Ca2+ diffusion waves play a significant role in shaping APs of PCs and could provide mechanistic insights into the increased arrhythmogeneity of PCs.
Fares, Souha
2017-01-01
Context. The Pain Catastrophizing Scale (PCS) is the most widely used measure of pain-specific catastrophizing. Objectives. The purpose of the present study was to develop and psychometrically evaluate an Arabic-language version of the PCS. Methods. In Study 1, 150 adult chronic nonmalignant pain patients seeking treatment at a hospital setting completed the PCS-A and a number of self-report measures assessing clinical parameters of pain, symptoms of depression, and quality of life. Study 2 employed a cold pressor pain task to examine the PCS-A in a sample of 44 healthy university students. Results. Exploratory factor analyses suggested a two-factor structure. Confirmatory factor analysis comparing the 2-factor model, Sullivan's original 3-factor model, and a 1-factor model based on the total score all provided adequate fit to the data. Cronbach's alpha coefficients across all models met or exceeded accepted standards of reliability. Catastrophizing was associated with higher levels of depression and increased pain intensity and interference. Catastrophizing predicted decreased quality of life, even after controlling for the contribution of gender, employment, depression, and pain interference. PCS-A scores were positively correlated with heightened experimental pain severity and decreased pain tolerance. Conclusion. The present results provide strong support for the psychometric properties of the PCS-A. PMID:28190958
Bioinspired Polymeric Photonic Crystals for High Cycling pH-Sensing Performance.
Fei, Xiang; Lu, Tao; Ma, Jun; Wang, Wanlin; Zhu, Shenmin; Zhang, Di
2016-10-12
Artificial photonic crystals (PCs) have been extensively studied to improve the sensing performance of poly(acrylic acid) (PAAc), as it can transform the PAAc volume change into optical signal which is easier to read. Nevertheless, these PCs are limited by the monostructure. We herein developed new photonic crystals (PCs) by coating acrylic acid and acrylamide (AAm) via in situ copolymerization onto Papilio paris wings having hierarchical, lamellar structure. Our PCs exhibited high performance of color tunability to environmental pH, as detected by reflectance spectra and visual observation. The introduction of AAm into the system created covalent bonding which robustly bridged the polymer with the wings, leading to an accurate yet broad variation of reflection wavelength to gauge environmental pH. The reflection wavelength can be tailored by the refractive index of the lamellar interspacing due to the swelling/deswelling of the polymer. The mechanism is not only supported by experimenta but proved by finite-difference time-domain simulation. Moreover, It is worth noting that the covalent bonding has provided the PCs-based pH sensor with high cycling performance, implying great potential in practical applications. The simple fabrication process is applicable to the development of a wide variety of stimuli-responsive PCs taking advantage of other polymers.
Law, Cheryl Suwen; Santos, Abel; Nemati, Mahdieh; Losic, Dusan
2016-06-01
This study presents a sawtooth-like pulse anodization approach aiming to create a new type of photonic crystal structure based on nanoporous anodic alumina. This nanofabrication approach enables the engineering of the effective medium of nanoporous anodic alumina in a sawtooth-like manner with precision. The manipulation of various anodization parameters such as anodization period, anodization amplitude, number of anodization pulses, ramp ratio and pore widening time allows a precise control and fine-tuning of the optical properties (i.e., characteristic transmission peaks and interferometric colors) exhibited by nanoporous anodic alumina photonic crystals (NAA-PCs). The effect of these anodization parameters on the photonic properties of NAA-PCs is systematically evaluated for the establishment of a fabrication methodology toward NAA-PCs with tunable optical properties. The effective medium of the resulting NAA-PCs is demonstrated to be optimal for the development of optical sensing platforms in combination with reflectometric interference spectroscopy (RIfS). This application is demonstrated by monitoring in real-time the formation of monolayers of thiol molecules (11-mercaptoundecanoic acid) on the surface of gold-coated NAA-PCs. The obtained results reveal that the adsorption mechanism between thiol molecules and gold-coated NAA-PCs follows a Langmuir isotherm model, indicating a monolayer sorption mechanism.
Whitney, Elizabeth R; Kemper, Thomas L; Rosene, Douglas L; Bauman, Margaret L; Blatt, Gene J
2008-02-15
In a study of human Purkinje cell (PC) number, a striking mismatch between the number of PCs observed with the Nissl stain and the number of PCs immunopositive for calbindin-D28k (CB) was identified in 2 of the 10 brains examined. In the remaining eight brains this mismatch was not observed. Further, in these eight brains, analysis of CB immunostained sections counterstained with the Nissl stain revealed that more than 99% Nissl stained PCs were also immunopositive for CB. In contrast, in the two discordant brains, only 10-20% of CB immunopositive PCs were also identified with the Nissl stain. Although this finding was unexpected, a historical survey of the literature revealed that Spielmeyer [Spielmeyer W. Histopathologie des nervensystems. Julius Springer: Berlin; 1922. p. 56-79] described human cases with PCs that lacked the expected Nissl staining intensity, an important historical finding and critical issue when studying postmortem human brains. The reason for this failure in Nissl staining is not entirely clear, but it may result from premortem circumstances since it is not accounted for by postmortem delay or processing variables. Regardless of the exact cause, these observations suggest that Nissl staining may not be a reliable marker for PCs and that CB is an excellent alternative marker.
Hepatocyte transplants improve liver function and encephalopathy in portacaval shunted rats.
Fogel, Wieslawa Agnieszka; Stasiak, Anna; Maksymowicz, Michał; Kobos, Jozef; Unzeta, Mercedes; Mussur, Miroslaw
2014-07-01
Rats with portacaval shunt (PCS) are useful experimental models of human hepatic encephalopathy in chronic liver dysfunction. We have previously shown that PCS modifies amine neurotransmitter systems in the CNS and increases voluntary alcohol intake by rats. Hepatocyte transplantation, used in acute liver failure, has recently also been applied to chronic liver diseases, which prompted us to investigate whether the altered brain amine system and the drinking behavior in long-term shunted rats could be normalized by hepatocyte transplants. Hepatocytes, isolated from syngeneic donors by collagenase digestion, were injected (3 × 10(6) cells/rat) into the pancreatic tail region, 6 months after PCS. Hepatic function was evaluated by measuring urine urea and plasma L-histidine concentrations. A free choice test with two bottles (tap water and 10% ethyl alcohol) was performed for 3 days to assess the rats' preference for alcohol. The rats were euthanized 2 months posttransplantation. Brain histamine and 5-hydroxyindoleacetic acid (5-HIAA) levels were measured by radioenzymatic assay and by HPLC-EC, respectively, N-tele-methylhistamine by GC/MS while MAOA and MAOB activities by isotopic procedures. Portacaval shunt rats with hepatocyte transplants gave more urea than before transplantation, with lower plasma L-His levels and higher body weight versus the PCS counterparts. Also, those rats consumed less alcohol. The CNS amines and 5-HIAA concentrations, as well as MAO-B activity, being abnormally high in untreated PCS rats, significantly reduced after PCS hepatocyte treatment. The results support the therapeutic values of hepatocyte transplants in chronic liver diseases and the temporary character of PCS-exerted CNS dysfunctions. © 2014 John Wiley & Sons Ltd.
Systematic Regional Variations in Purkinje Cell Spiking Patterns
Xiao, Jianqiang; Cerminara, Nadia L.; Kotsurovskyy, Yuriy; Aoki, Hanako; Burroughs, Amelia; Wise, Andrew K.; Luo, Yuanjun; Marshall, Sarah P.; Sugihara, Izumi; Apps, Richard; Lang, Eric J.
2014-01-01
In contrast to the uniform anatomy of the cerebellar cortex, molecular and physiological studies indicate that significant differences exist between cortical regions, suggesting that the spiking activity of Purkinje cells (PCs) in different regions could also show distinct characteristics. To investigate this possibility we obtained extracellular recordings from PCs in different zebrin bands in crus IIa and vermis lobules VIII and IX in anesthetized rats in order to compare PC firing characteristics between zebrin positive (Z+) and negative (Z−) bands. In addition, we analyzed recordings from PCs in the A2 and C1 zones of several lobules in the posterior lobe, which largely contain Z+ and Z− PCs, respectively. In both datasets significant differences in simple spike (SS) activity were observed between cortical regions. Specifically, Z− and C1 PCs had higher SS firing rates than Z+ and A2 PCs, respectively. The irregularity of SS firing (as assessed by measures of interspike interval distribution) was greater in Z+ bands in both absolute and relative terms. The results regarding systematic variations in complex spike (CS) activity were less consistent, suggesting that while real differences can exist, they may be sensitive to other factors than the cortical location of the PC. However, differences in the interactions between SSs and CSs, including the post-CS pause in SSs and post-pause modulation of SSs, were also consistently observed between bands. Similar, though less strong trends were observed in the zonal recordings. These systematic variations in spontaneous firing characteristics of PCs between zebrin bands in vivo, raises the possibility that fundamental differences in information encoding exist between cerebellar cortical regions. PMID:25144311
JAK/STAT autocontrol of ligand-producing cell number through apoptosis.
Borensztejn, Antoine; Boissoneau, Elisabeth; Fernandez, Guillaume; Agnès, François; Pret, Anne-Marie
2013-01-01
During development, specific cells are eliminated by apoptosis to ensure that the correct number of cells is integrated in a given tissue or structure. How the apoptosis machinery is activated selectively in vivo in the context of a developing tissue is still poorly understood. In the Drosophila ovary, specialised follicle cells [polar cells (PCs)] are produced in excess during early oogenesis and reduced by apoptosis to exactly two cells per follicle extremity. PCs act as an organising centre during follicle maturation as they are the only source of the JAK/STAT pathway ligand Unpaired (Upd), the morphogen activity of which instructs distinct follicle cell fates. Here we show that reduction of Upd levels leads to prolonged survival of supernumerary PCs, downregulation of the pro-apoptotic factor Hid, upregulation of the anti-apoptotic factor Diap1 and inhibition of caspase activity. Upd-mediated activation of the JAK/STAT pathway occurs in PCs themselves, as well as in adjacent terminal follicle and interfollicular stalk cells, and inhibition of JAK/STAT signalling in any one of these cell populations protects PCs from apoptosis. Thus, a Stat-dependent unidentified relay signal is necessary for inducing supernumerary PC death. Finally, blocking apoptosis of PCs leads to specification of excess adjacent border cells via excessive Upd signalling. Our results therefore show that Upd and JAK/STAT signalling induce apoptosis of supernumerary PCs to control the size of the PC organising centre and thereby produce appropriate levels of Upd. This is the first example linking this highly conserved signalling pathway with developmental apoptosis in Drosophila.
Does pelvicaliceal system anatomy affect success of percutaneous nephrolithotomy?
Binbay, Murat; Akman, Tolga; Ozgor, Faruk; Yazici, Ozgur; Sari, Erhan; Erbin, Akif; Kezer, Cem; Sarilar, Omer; Berberoglu, Yalcın; Muslumanoglu, Ahmet Yaser
2011-10-01
To investigate the effect of the pelvicaliceal system (PCS) anatomy on the percutaneous nephrolithotomy (PCNL) success rate. Although the caliceal anatomy is effective for stone clearance after shock wave lithotripsy and retrograde intrarenal lithotripsy, the effect of the caliceal anatomy after PCNL has not been evaluated to date. A total of 498 patients who had undergone PCNL and preoperative intravenous urography were enrolled in our study. Kidney-related anatomic factors, such as the PCS surface area and type, degree of hydronephrosis, infundibulopelvic angle, upper-lower calix angle, infundibular length, and infundibular width were calculated using intravenous urography. The association between the PCNL success rate and kidney-related anatomic factors was retrospectively analyzed using chi-square tests, Fisher's exact test, Mann-Whitney U test, and forward stepwise regression analysis. A success rate of 78.1% was achieved. No difference was seen the success rates among the PCS types. The mean PCS surface area was 20.1 ± 9.7 cm(2) in patients with successful outcomes and 24.5 ± 10.2 cm(2) in patients with remaining stones (P = .001). The mean infundibulopelvic angle, upper-lower calix angle, infundibular length, and infundibular width were similar in both groups. Multivariate binary logistic regression analysis showed that stone configuration and PCS surface area were independent factors affecting the PCNL success rates. The results of our study have shown that the PCS surface area is the only anatomic factor that affects the PCNL success rate and patients with a PCS surface area <20.5 cm(2) have greater PCNL success. Copyright © 2011 Elsevier Inc. All rights reserved.
Yu, Yinhui; Chen, Xinyi; Hua, Huixia; Wu, Menghan; Lai, Kairan; Yao, Ke
2016-08-01
To explore efficacy and safety outcomes in patients undergoing femtosecond laser-assisted cataract surgery (FLACS) versus manual phacoemulsification cataract surgery (PCS). Prospective consecutive nonrandomized comparative cohort study. A total of 124 eyes from 106 patients (70 in FLACS and 54 in PCS). Comparison of FLACS with PCS over 6 months. Macular central subfield thickness (CST), cube volume (CV), cube average thickness (CAT), endothelial cell density (ECD), central corneal thickness (CCT) and photon count value (PCV). CST, CV and CAT increased postoperatively, which did not return to preoperative levels by 6 months. The values were similar between groups throughout the follow-up, and comparison of changes from baseline also showed no significant difference. Preoperative ECD showed significant difference, which decreased postoperatively and remained stable during follow-up, being lowest at 1 month. FLACS had greater endothelial cell loss than PCS, which was not significant. CCT in both groups increased, reaching maximum on day one and tended to decrease thereafter. No significant differences were found regarding postoperative values and the mean increase. In both groups, mean PCV increased from preoperatively to day one, week one and month one. Flare values in FLACS were lower than PCS, reaching statistical significance at 6 months (P = 0.001). However, the differences in changes of PCV were not significantly different at any visit. Both FLACS and PCS achieved similar safety and efficacy outcomes for performing cataract surgery. Flare values in eyes with FLACS were lower than those with PCS at 6 months postoperatively. © 2015 Royal Australian and New Zealand College of Ophthalmologists.
Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler
Stewart, Justin; Sleeth, Darrah K.; Handy, Rod G.; Pahler, Leon F.; Anthony, T. Renee; Volckens, John
2017-01-01
A newly designed, low-cost, disposable inhalable aerosol sampler was developed to assess workers personal exposure to inhalable particles. This sampler was originally designed to operate at 10 L/min to increase sample mass and, therefore, improve analytical detection limits for filter-based methods. Computational fluid dynamics modeling revealed that sampler performance (relative to aerosol inhalability criteria) would not differ substantially at sampler flows of 2 and 10 L/min. With this in mind, the newly designed inhalable aerosol sampler was tested in a wind tunnel, simultaneously, at flows of 2 and 10 L/min flow. A mannequin was equipped with 6 sampler/pump assemblies (three pumps operated at 2 L/min and three pumps at 10 L/min) inside a wind tunnel, operated at 0.2 m/s, which has been shown to be a typical indoor workplace wind speed. In separate tests, four different particle sizes were injected to determine if the sampler’s performance with the new 10 L/min flow rate significantly differed to that at 2 L/min. A comparison between inhalable mass concentrations using a Wilcoxon signed rank test found no significant difference in the concentration of particles sampled at 10 and 2 L/min for all particle sizes tested. Our results suggest that this new aerosol sampler is a versatile tool that can improve exposure assessment capabilities for the practicing industrial hygienist by improving the limit of detection and allowing for shorting sampling times. PMID:27676440
NASA Astrophysics Data System (ADS)
May, Andrew A.; Ashman, Paul; Huang, Jiaoyan; Dhaniyala, Suresh; Holsen, Thomas M.
2011-08-01
Computational fluid dynamics (CFD) simulations coupled with wind tunnel-experiments were used to determine the sampling rate (SR) of the widely used polyurethane foam (PUF) disk passive sampler. In the wind-tunnel experiments, water evaporation rates from a water saturated PUF disk installed in the sampler housing were determined by measuring weight loss over time. In addition, a modified passive sampler designed to collect elemental mercury (Hg 0) with gold-coated filters was used. Experiments were carried out at different wind speeds and various sampler angles. The SRs obtained from wind-tunnel experiments were compared to those obtained from the field by scaling the values by the ratios of air diffusivities. Three-dimensional (3D) CFD simulations were also used to generate SRs for both polychlorinated biphenyls (PCBs) and Hg 0. Overall, the modeled and measured SRs agree well and are consistent with the values obtained from field studies. As previously observed, the SRs increased linearly with increasing wind speed. In addition, it was determined that the SR was strongly dependent on the angle of the ambient wind. The SRs increased when the base was tilted up pointing into the wind and when the base was tilted down (i.e., such that the top of the sampler was facing the wind) the SR decreased initially and then increased. The results suggest that there may be significant uncertainty in concentrations obtained from passive sampler measurements without knowledge of wind speed and wind angle relative to the sampler.
Choi, Jong-Il; Kim, Young-Hoon
2016-01-01
Background The main purpose of performing radiofrequency catheter ablation (RFCA) in atrial fibrillation (AF) patients is to improve the quality of life (QoL) and alleviate AF-related symptoms. We aimed to determine the qualitative and quantitative effects of RFCA on the QoL in AF patients. Methods We performed a systemic review and meta-analysis using a random effects model. We searched for the studies that reported the physical component summary score (PCS) and mental component summary score (MCS) of the short form-36, a validated system to assess and quantify the QoL, before and after RFCA in AF patients. PCS and MCS are T-scores with a mean of 50 and standard deviation of 10. Results Of the 470 studies identified through systematic search, we included 13 studies for pre-RFCA vs. the post-RFCA analysis and 5 studies for treatment success vs. AF recurrence analyses. In the pre-RFCA vs. post-RFCA analysis, RFCA was associated with a significant increase in both the PCS (weighted mean difference [WMD] = 6.33 [4.81–7.84]; p < 0.001) and MCS (WMD = 7.80 [6.15–9.44]; p < 0.001). The ΔPCS (post-RFCA PCS–pre-RFCA PCS) and ΔMCS values were used for the treatment success vs. AF recurrence analysis. Patients with successful ablation had a higher ΔPCS (WMD = 7.46 [4.44–10.49]; p < 0.001) and ΔMCS (WMD = 7.59 [4.94–10.24]; p < 0.001). Conclusions RFCA is associated with a significant increase in the PCS and MCS in AF patients. Patients without AF recurrence after RFCA had a better improvement in the PCS and MCS than patients who had AF recurrence. PMID:27681507
Hirokawa, Mitsuyoshi; Nishihara, Eijun; Takada, Nami; Higuchi, Miyoko; Kotakemori, Masumi; Hayashi, Toshitetsu; Miyauchi, Akira
2018-02-26
Hashimoto's thyroiditis with heavy lymphoplasmacytic infiltration is a common comorbidity of immunoglobulin G4 (IgG4)-related thyroiditis and Warthin-like papillary thyroid carcinoma (WL-PTC). We hypothesized that WL-PTC may have a strong association with IgG4-related thyroiditis. To validate this hypothesis, we clinically and immunohistochemically studied 17 WL-PTC cases. Fourteen patients (82.4%) had anti-thyroglobulin antibody and were confirmed to have Hashimoto's thyroiditis through microscopic analysis. Among them, five (29.4%) had disease consistent with IgG4-related thyroiditis but did not exhibit a "storiform" pattern or obliterative phlebitis. IgG4-related diseases were not found in other organs. No cases with serum IgG4 level of >135 mg/dL were noted. A total of 94.1% of WL-PTC cases had IgG4-positive plasma cells ( + PCs) in the stroma, and cases with rich IgG4 + PCs were more frequently associated with Hashimoto's thyroiditis than those with poor IgG4 + PCs. In this study, all three cases without Hashimoto's thyroiditis had poor IgG4 + PCs, and one of them did not exhibit IgG4 + PCs in the stroma of WL-PTC and Hashimoto's thyroiditis. Nodal metastatic lesions were seen in eight cases, all of which were not WL-PTC. As such, we should consider that the Hashimoto's disease with rich IgG4 + PCs seen in our cases is representative of non-IgG4-related disease and not IgG4-related disease involving multiple organs. This study is the first to demonstrate the presence of IgG4 + PCs in the stroma of WL-PTC. We concluded that the appearance of IgG4 + PCs in the stroma of WL-PTC may be related to Hashimoto's thyroiditis with rich IgG4 + PC.
Katsetos, C D; Spandou, E; Legido, A; Taylor, M L; Zanelli, S A; de Chadarevian, J P; Christakos, S; Mishra, O P; Delivoria-Papadopoulos, M
2001-05-01
Purkinje cells (PCs) are vulnerable to hypoxic/ischemic insults and rich in calcium and calcium-buffering/sequestering systems, including calcium-binding proteins (CaBPs). Calbindin-D28k is an EF-hand CaBP, which is highly expressed in PCs where it acts primarily as a cellular Ca++ buffer. Elevation of [Ca++] in the cytosol and nuclei of PCs is pivotal in hypoxic/ischemic cell death. We hypothesize that hypoxia results in decreased concentration, or availability of calbindin-D28k in PCs, thereby decreasing their buffering capacity and resulting in increase of intracellular and intranuclear [Ca++]. Cerebellar tissues from normoxic fetuses were compared to fetuses obtained from term pregnant guinea pigs exposed to hypoxia [7% FiO2] for 60 min. The pregnant guinea pigs were either killed upon delivery immediately following hypoxia (Hx0h) or were subsequently allowed to recover for 24 h (Hx24h) or 72 h (Hx72h). Fetal brain hypoxia was documented biochemically by a decrease in brain tissue levels of ATP and phosphocreatine. Compared to normoxic fetuses, there is a predominantly somatodendritic loss or decrease of calbindin-D28k immunohistochemical staining in PCs of Hx0h (p < 0.005), Hx24h (p < 0.05), and Hx72h (p < 0.005) fetuses. Hypoxia-induced alterations of calbindin-D28k immunoreactivity are qualitatively similar at all time points and include a distinctive intranuclear localization in subpopulations of PCs. A similar trend is demonstrated by immunoblotting. Subpopulations of TUNEL+/calbindin-D28k- PCs lacking morphologic features of apoptosis or necrosis are demonstrated in Hx24h and Hx72h fetuses. The present study demonstrates an abrogating effect of perinatal hypoxia on calbindin-D28k immunoreactivity in cerebellar PCs. The perturbation of this Ca++ buffer protein in hypoxia-induced neuronal injury may herald delayed cell death or degeneration.
Development and Validation of a Daily Pain Catastrophizing Scale.
Darnall, Beth D; Sturgeon, John A; Cook, Karon F; Taub, Chloe J; Roy, Anuradha; Burns, John W; Sullivan, Michael; Mackey, Sean C
2017-09-01
To date, there is no validated measure for pain catastrophizing at the daily level. The Pain Catastrophizing Scale (PCS) is widely used to measure trait pain catastrophizing. We sought to develop and validate a brief, daily version of the PCS for use in daily diary studies to facilitate research on mechanisms of catastrophizing treatment, individual differences in self-regulation, and to reveal the nuanced relationships between catastrophizing, correlates, and pain outcomes. After adapting the PCS for daily use, we evaluated the resulting 14 items using 3 rounds of cognitive interviews with 30 adults with chronic pain. We refined and tested the final daily PCS in 3 independent, prospective, cross-sectional, observational validation studies conducted in a combined total of 519 adults with chronic pain who completed online measures daily for 14 consecutive days. For study 1 (N = 131), exploratory factor analysis revealed adequate fit and-unexpectedly-unidimensionality for item responses to the daily PCS. Study 2 (N = 177) correlations indicated adequate association with related constructs (anger, anxiety, pain intensity, depression). Similarly, results for study 3 (N = 211) revealed expected correlations for daily PCS and measures of daily constructs including physical activity, sleep, energy level, and positive affect. Results from complex/multilevel confirmatory factor analysis confirmed good fit to a unidimensional model. Scores on the daily PCS were statistically comparable with and more parsimonious than the full 14-item version. Next steps include evaluation of score validity in populations with medical diagnoses, greater demographic diversity, and in patients with acute pain. This article describes the development and validation of a daily PCS. This daily measure may facilitate research that aims to characterize pain mechanisms, individual differences in self-regulation, adaptation, and nuanced relationships between catastrophizing, correlates, and pain outcomes. Copyright © 2017 American Pain Society. Published by Elsevier Inc. All rights reserved.
Sharma, Monica; Sandhir, Rajat; Singh, Anuradha; Kumar, Pankaj; Mishra, Ankita; Jachak, Sanjay; Singh, Sukhvinder P; Singh, Jagdeep; Roy, Joy
2016-01-01
Phenolic compounds (PCs) affect the bread quality and can also affect the other types of end-use food products such as chapatti (unleavened flat bread), now globally recognized wheat-based food product. The detailed analysis of PCs and their biosynthesis genes in diverse bread wheat ( Triticum aestivum ) varieties differing for chapatti quality have not been studied. In this study, the identification and quantification of PCs using UPLC-QTOF-MS and/or MS/MS and functional genomics techniques such as microarrays and qRT-PCR of their biosynthesis genes have been studied in a good chapatti variety, "C 306" and a poor chapatti variety, "Sonalika." About 80% (69/87) of plant phenolic compounds were tentatively identified in these varieties. Nine PCs (hinokinin, coutaric acid, fertaric acid, p-coumaroylqunic acid, kaempferide, isorhamnetin, epigallocatechin gallate, methyl isoorientin-2'-O-rhamnoside, and cyanidin-3-rutinoside) were identified only in the good chapatti variety and four PCs (tricin, apigenindin, quercetin-3-O-glucuronide, and myricetin-3-glucoside) in the poor chapatti variety. Therefore, about 20% of the identified PCs are unique to each other and may be "variety or genotype" specific PCs. Fourteen PCs used for quantification showed high variation between the varieties. The microarray data of 44 phenolic compound biosynthesis genes and 17 of them on qRT-PCR showed variation in expression level during seed development and majority of them showed low expression in the good chapatti variety. The expression pattern in the good chapatti variety was largely in agreement with that of phenolic compounds. The level of variation of 12 genes was high between the good and poor chapatti quality varieties and has potential in development of markers. The information generated in this study can be extended onto a larger germplasm set for development of molecular markers using QTL and/or association mapping approaches for their application in wheat breeding.
Sharma, Monica; Sandhir, Rajat; Singh, Anuradha; Kumar, Pankaj; Mishra, Ankita; Jachak, Sanjay; Singh, Sukhvinder P.; Singh, Jagdeep; Roy, Joy
2016-01-01
Phenolic compounds (PCs) affect the bread quality and can also affect the other types of end-use food products such as chapatti (unleavened flat bread), now globally recognized wheat-based food product. The detailed analysis of PCs and their biosynthesis genes in diverse bread wheat (Triticum aestivum) varieties differing for chapatti quality have not been studied. In this study, the identification and quantification of PCs using UPLC-QTOF-MS and/or MS/MS and functional genomics techniques such as microarrays and qRT-PCR of their biosynthesis genes have been studied in a good chapatti variety, “C 306” and a poor chapatti variety, “Sonalika.” About 80% (69/87) of plant phenolic compounds were tentatively identified in these varieties. Nine PCs (hinokinin, coutaric acid, fertaric acid, p-coumaroylqunic acid, kaempferide, isorhamnetin, epigallocatechin gallate, methyl isoorientin-2′-O-rhamnoside, and cyanidin-3-rutinoside) were identified only in the good chapatti variety and four PCs (tricin, apigenindin, quercetin-3-O-glucuronide, and myricetin-3-glucoside) in the poor chapatti variety. Therefore, about 20% of the identified PCs are unique to each other and may be “variety or genotype” specific PCs. Fourteen PCs used for quantification showed high variation between the varieties. The microarray data of 44 phenolic compound biosynthesis genes and 17 of them on qRT-PCR showed variation in expression level during seed development and majority of them showed low expression in the good chapatti variety. The expression pattern in the good chapatti variety was largely in agreement with that of phenolic compounds. The level of variation of 12 genes was high between the good and poor chapatti quality varieties and has potential in development of markers. The information generated in this study can be extended onto a larger germplasm set for development of molecular markers using QTL and/or association mapping approaches for their application in wheat breeding. PMID:28018403
Lin, Cheng-Jui; Wu, Vincent; Wu, Pei-Chen; Wu, Chih-Jen
2015-01-01
Indoxyl sulfate (IS) and p-cresyl sulfate (PCS) are protein-bound uremic toxins that increase in the sera of patients with chronic kidney disease (CKD), and are not effectively removed by dialysis. The purpose of this meta-analysis was to investigate the relationships of PCS and IS with cardiovascular events and all-cause mortality in patients with CKD stage 3 and above. Medline, Cochrane, and EMBASE databases were searched until January 1, 2014 with combinations of the following keywords: chronic renal failure, end-stage kidney disease, uremic toxin, uremic retention, indoxyl sulfate, p-cresyl sulfate. Inclusion criteria were: 1) Patients with stage 1 to 5 CKD; 2) Prospective study; 3) Randomized controlled trial; 4) English language publication. The associations between serum levels of PCS and IS and the risks of all-cause mortality and cardiovascular events were the primary outcome measures. Of 155 articles initially identified, 10 prospective and one cross-sectional study with a total 1,572 patients were included. Free PCS was significantly associated with all-cause mortality among patients with chronic renal failure (pooled OR = 1.16, 95% CI = 1.03 to 1.30, P = 0.013). An elevated free IS level was also significantly associated with increased risk of all-cause mortality (pooled OR = 1.10, 95% CI = 1.03 to 1.17, P = 0.003). An elevated free PCS level was significantly associated with an increased risk of cardiovascular events among patients with chronic renal failure (pooled OR = 1.28, 95% CI = 1.10 to 1.50, P = 0.002), while free IS was not significantly associated with risk of cardiovascular events (pooled OR = 1.05, 95% CI = 0.98 to 1.13, P = 0.196). Elevated levels of PCS and IS are associated with increased mortality in patients with CKD, while PCS, but not IS, is associated with an increased risk of cardiovascular events.
Gómez-Virgilio, Laura; Ramírez-Rodríguez, Gerardo Bernabé; Sánchez-Torres, Carmen; Ortiz-López, Leonardo; Meraz-Ríos, Marco Antonio
2018-03-01
Neurogenesis plays a significant role during adulthood, and the observation that neural stem cells reside in the central nervous system and the olfactory epithelium has attracted attention due to their importance in neuronal regeneration. In addition, soluble factors (SFs) release by neural stem cells may modulate the neurogenic process. Thus, in this study, we identified the SFs released by olfactory human neural stem/progenitor cells (hNS/PCs-OE). These cells express Ki67, nestin, and βIII-tubulin, indicating their neural lineage. The hNS/PCs-OE also express PSD95 and tau proteins during proliferation, but increased levels are observed after differentiation. Thus, we evaluated the effects of SFs from hNS/PCs-OE on the viability, proliferation, and differentiation potential of adult murine hippocampal neural precursor cells (AHPCs). SFs from hNS/PCs-OE maintain cells in the precursor and proliferative stages and mainly promote the astrocytic differentiation of AHPCs. These effects involved the activation, as measured by phosphorylation, of several proteins (Erk1/2; Akt/PRAS40/GSK3β and JAK/STAT) involved in key events of the neurogenic process. Moreover, according to the results from the antibody-based microarray approach, among the soluble factors, hNS/PCs-OE produce interleukin-6 (IL-6) and neurotrophin 4 (NT4). However, residual epidermal growth factor (EGF) was also detected. These proteins partially reproduced the effects of SFs from hNS/PCs-OE on AHPCs, and the mechanism underlying these effects is mediated by Src proteins, which have been implicated in EGF-induced transactivation of TrkB receptor. The results of the present study suggest the potential use of SFs from hNS/PCs-OE in controlling the differentiation potential of AHPCs. Thus, the potential clinical relevance of hNS/PCs-OE is worth pursuing.
Kusano, Kristofer D.; Gabler, Hampton C.
2010-01-01
To mitigate the severity of rear-end and other collisions, Pre-Crash Systems (PCS) are being developed. These active safety systems utilize radar and/or video cameras to determine when a frontal crash, such as a front-to-back rear-end collisions, is imminent and can brake autonomously, even with no driver input. Of these PCS features, the effects of autonomous pre-crash braking are estimated. To estimate the maximum potential for injury reduction due to autonomous pre-crash braking in the striking vehicle of rear-end crashes, a methodology is presented for determining 1) the reduction in vehicle crash change in velocity (ΔV) due to PCS braking and 2) the number of injuries that could be prevented due to the reduction in collision severity. Injury reduction was only performed for belted drivers, as unbelted drivers have an unknown risk of being thrown out of position. The study was based on 1,406 rear-end striking vehicles from NASS / CDS years 1993 to 2008. PCS parameters were selected from realistic values and varied to examine the effect on system performance. PCS braking authority was varied from 0.5 G’s to 0.8 G’s while time to collision (TTC) was held at 0.45 seconds. TTC was then varied from 0.3 second to 0.6 seconds while braking authority was held constant at 0.6 G’s. A constant braking pulse (step function) and ramp-up braking pulse were used. The study found that automated PCS braking could reduce the crash ΔV in rear-end striking vehicles by an average of 12% – 50% and avoid 0% – 14% of collisions, depending on PCS parameters. Autonomous PCS braking could potentially reduce the number of injured drivers who are belted by 19% to 57%. PMID:21050603
Multi-kanban mechanism for personal computer disassembly
NASA Astrophysics Data System (ADS)
Udomsawat, Gun; Gupta, Surendra M.; Kamarthi, Sagar V.
2004-12-01
The use of personal computers (PCs) continues to increase every year. According to a 1999 figure, 50 percent of all US households owned PCs, a figure that continues to rise every year. With continuous development of sophisticated software, PCs are becoming increasingly powerful. In addition, the price of a PC continues to steadily decline. Furthermore, the typical life of a PC in the workplace is approximately two to three years while in the home it is three to five years. As these PCs become obsolete, they are replaced and the old PCs are disposed of. It is estimated that between 14 and 20 million PCs are retired annually in the US. While 20 to 30% of the units may be resold, the others are discarded. These discards represent a significant potential source of lead for the waste stream. In some communities, waste cathode ray tubes (CRTs) represent the second largest source of lead in the waste stream after vehicular lead acid batteries. PCs are, therefore, not suitable for dumping in landfills. Besides, several components of a PC can be reused and then there are other valuable materials that can also be harvested. And with the advent of product stewardship, product recovery is the best solution for manufacturers. Disassembly line is perhaps the most suitable set up for disassembling PCs. However, planning and scheduling of disassembly on a disassembly line is complicated. In this paper, we discuss some of the complications including product arrival, demand arrival, inventory fluctuation and production control mechanisms. We then show how to overcome them by implementing a multi-kanban mechanism in the PC disassembly line setting. The multi-kanban mechanism relies on dynamic routing of kanbans according to the state of the system. We investigate the multi-kanban mechanism using simulation and demonstrate that this mechanism is superior to the traditional push system in terms of controlling the system"s inventory while maintaining a decent customer service level.
Samplers for evaluation and quantification of ultra-low volume space sprays
USDA-ARS?s Scientific Manuscript database
A field study was conducted to investigate the suitability of sampling devices for quantification of spray deposition from ULV space sprays. Five different samplers were included in an experiment conducted in an open grassy field. Samplers included horizontally stretched stationary cotton ribbon at ...
This Paper covers the basics of passive sampler design, compares passive samplers to conventional methods of air sampling, and discusses considerations when implementing a passive sampling program. The Paper also discusses field sampling and sample analysis considerations to ensu...
7 CFR 61.41 - Unlicensed persons must not represent themselves as licensed samplers.
Code of Federal Regulations, 2010 CFR
2010-01-01
...) AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946 AND THE EGG PRODUCTS... represent themselves as licensed samplers. No person shall in any way represent himself to be a sampler...
The report describes the development of a sampler for particulate-associated and low volatility organic pollutants in residential air. The performance of the sampler inlet, which is compatible with the proposed PM-10 regulations for particulate sampling, is documented under a var...
USDA-ARS?s Scientific Manuscript database
Passive capillary samplers (PCAPs) are widely used to monitor, measure and sample drainage water under saturated and unsaturated soil conditions in the vadose zone. The objective of this study was to evaluate the performance and accuracy of automated passive capillary sampler for estimating drainage...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
Passive samplers are increasingly being considered for analyses of waters for screening applications, to monitor for the presence of unwanted chemical compounds. Passive samplers typically work by accumulating and concentrating chemicals from the surrounding water over time, all...
The purpose of this SOP is to describe the procedures for calibrating Harvard particulate matter (PM) samplers. This procedure applies directly to the Harvard particulate matter (PM) samplers used during the Arizona NHEXAS project and the "Border" study. Keywords: lab; equipmen...
Quantitative organic vapor-particle sampler
Gundel, Lara; Daisey, Joan M.; Stevens, Robert K.
1998-01-01
A quantitative organic vapor-particle sampler for sampling semi-volatile organic gases and particulate components. A semi-volatile organic reversible gas sorbent macroreticular resin agglomerates of randomly packed microspheres with the continuous porous structure of particles ranging in size between 0.05-10 .mu.m for use in an integrated diffusion vapor-particle sampler.
7 CFR 800.171 - Who may be licensed or authorized.
Code of Federal Regulations, 2010 CFR
2010-01-01
... individual is to be licensed. (d) Competency determinations—(1) Agency samplers and technicians. The competency of an applicant for a license as a sampler, inspection technician, or weighing technician shall be..., contract samplers, and technicians. The competency of an applicant for a license as an inspector or weigher...
Two modified passive samplers were evaluated at multiple field locations. The sampling rate (SR) of the modified polyurethane foam (PUF)-disk passive sampler for total gaseous mercury (TGM) using gold-coated quartz fiber filters (GcQFF) and gaseous oxidized mercury (GOM) using io...
Efficiency tests of samplers for microbiological aerosols, a review
NASA Technical Reports Server (NTRS)
Henningson, E.; Faengmark, I.
1984-01-01
To obtain comparable results from studies using a variety of samplers of microbiological aerosols with different collection performances for various particle sizes, methods reported in the literature were surveyed, evaluated, and tabulated for testing the efficiency of the samplers. It is concluded that these samplers were not thoroughly tested, using reliable methods. Tests were conducted in static air chambers and in various outdoor and work environments. Results are not reliable as it is difficult to achieve stable and reproducible conditions in these test systems. Testing in a wind tunnel is recommended.
McEwan, T.E.
1994-09-06
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, [+-] UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals. 16 figs.
McEwan, T.E.
1996-06-04
An ultra-wideband (UWB) receiver utilizes a strobed input line with a sampler connected to an amplifier. In a differential configuration, {+-}UWB inputs are connected to separate antennas or to two halves of a dipole antenna. The two input lines include samplers which are commonly strobed by a gating pulse with a very low duty cycle. In a single ended configuration, only a single strobed input line and sampler is utilized. The samplers integrate, or average, up to 10,000 pulses to achieve high sensitivity and good rejection of uncorrelated signals. 21 figs.
Evaluation of particulate air samplers for airborne aflatoxin B1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silas, J.C.; Harrison, M.A.; Carpenter, J.A.
Five air samplers (Millipore, all-glass impinger, centrifugal, Andersen, and absorbent cotton) were evaluated for their ability to collect airborne grain particles contaminated with aflatoxin B1. Corn dust containing 100 micrograms aflatoxin B1/g was aerosolized within a containment system. Each device sampled 100 I air, thus exchanging the air in the chamber two times. Aflatoxin B1 was extracted from all sampling matrices and was detected and quantitated with thin-layer chromatography and scanning fluorodensitometry. The highest efficiency was obtained with the Millipore sampler, while the efficiencies of the centrifugal and the cotton samplers were almost identical. Efficiency of an Andersen was less,more » with no toxin recovered from an all-glass impinger. Measurement of particle size was accomplished with the Andersen sampler.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hou Fengji; Hogg, David W.; Goodman, Jonathan
Markov chain Monte Carlo (MCMC) proves to be powerful for Bayesian inference and in particular for exoplanet radial velocity fitting because MCMC provides more statistical information and makes better use of data than common approaches like chi-square fitting. However, the nonlinear density functions encountered in these problems can make MCMC time-consuming. In this paper, we apply an ensemble sampler respecting affine invariance to orbital parameter extraction from radial velocity data. This new sampler has only one free parameter, and does not require much tuning for good performance, which is important for automatization. The autocorrelation time of this sampler is approximatelymore » the same for all parameters and far smaller than Metropolis-Hastings, which means it requires many fewer function calls to produce the same number of independent samples. The affine-invariant sampler speeds up MCMC by hundreds of times compared with Metropolis-Hastings in the same computing situation. This novel sampler would be ideal for projects involving large data sets such as statistical investigations of planet distribution. The biggest obstacle to ensemble samplers is the existence of multiple local optima; we present a clustering technique to deal with local optima by clustering based on the likelihood of the walkers in the ensemble. We demonstrate the effectiveness of the sampler on real radial velocity data.« less
Review of atrazine sampling by polar organic chemical integrative samplers and Chemcatcher.
Booij, Kees; Chen, Sunmao
2018-04-24
A key success factor for the performance of passive samplers is the proper calibration of sampling rates. Sampling rates for a wide range of polar organic compounds are available for Chemcatchers and polar organic chemical integrative samplers (POCIS), but the mechanistic models that are needed to understand the effects of exposure conditions on sampling rates need improvement. Literature data on atrazine sampling rates by these samplers were reviewed with the aim of assessing what can be learned from literature reports of this well-studied compound and identifying knowledge gaps related to the effects of flow and temperature. The flow dependency of sampling rates could be described by a mass transfer resistance model with 1 (POCIS) or 2 (Chemcatcher) adjustable parameters. Literature data were insufficient to evaluate the temperature effect on the sampling rates. An evaluation of reported sampler configurations showed that standardization of sampler design can be improved: for POCIS with respect to surface area and sorbent mass, and for Chemcatcher with respect to housing design. Several reports on atrazine sampling could not be used because the experimental setups were insufficiently described with respect to flow conditions. Recommendations are made for standardization of sampler layout and documentation of flow conditions in calibration studies. Environ Toxicol Chem 2018;9999:1-13. © 2018 SETAC. © 2018 SETAC.
Performance study of personal inhalable aerosol samplers at ultra-low wind speeds.
Sleeth, Darrah K; Vincent, James H
2012-03-01
The assessment of personal inhalable aerosol samplers in a controlled laboratory setting has not previously been carried out at the ultra-low wind speed conditions that represent most modern workplaces. There is currently some concern about whether the existing inhalable aerosol convention is appropriate at these low wind speeds and an alternative has been suggested. It was therefore important to assess the performance of the most common personal samplers used to collect the inhalable aerosol fraction, especially those that were designed to match the original curve. The experimental set-up involved use of a hybrid ultra-low speed wind tunnel/calm air chamber and a rotating, heating breathing mannequin to measure the inhalable fraction of aerosol exposure. The samplers that were tested included the Institute of Occupational Medicine (IOM), Button, and GSP inhalable samplers as well as the closed-face cassette sampler that has been (and still is) widely used by occupational hygienists in many countries. The results showed that, down to ∼0.2 m s(-1), the samplers matched the current inhalability criterion relatively well but were significantly greater than this at the lowest wind speed tested. Overall, there was a significant effect of wind speed on sampling efficiency, with lower wind speeds clearly associated with an increase in sampling efficiency.
NASA Astrophysics Data System (ADS)
Zhu, Gaofeng; Li, Xin; Ma, Jinzhu; Wang, Yunquan; Liu, Shaomin; Huang, Chunlin; Zhang, Kun; Hu, Xiaoli
2018-04-01
Sequential Monte Carlo (SMC) samplers have become increasing popular for estimating the posterior parameter distribution with the non-linear dependency structures and multiple modes often present in hydrological models. However, the explorative capabilities and efficiency of the sampler depends strongly on the efficiency in the move step of SMC sampler. In this paper we presented a new SMC sampler entitled the Particle Evolution Metropolis Sequential Monte Carlo (PEM-SMC) algorithm, which is well suited to handle unknown static parameters of hydrologic model. The PEM-SMC sampler is inspired by the works of Liang and Wong (2001) and operates by incorporating the strengths of the genetic algorithm, differential evolution algorithm and Metropolis-Hasting algorithm into the framework of SMC. We also prove that the sampler admits the target distribution to be a stationary distribution. Two case studies including a multi-dimensional bimodal normal distribution and a conceptual rainfall-runoff hydrologic model by only considering parameter uncertainty and simultaneously considering parameter and input uncertainty show that PEM-SMC sampler is generally superior to other popular SMC algorithms in handling the high dimensional problems. The study also indicated that it may be important to account for model structural uncertainty by using multiplier different hydrological models in the SMC framework in future study.
Wood Dust Sampling: Field Evaluation of Personal Samplers When Large Particles Are Present
Lee, Taekhee; Harper, Martin; Slaven, James E.; Lee, Kiyoung; Rando, Roy J.; Maples, Elizabeth H.
2011-01-01
Recent recommendations for wood dust sampling include sampling according to the inhalable convention of International Organization for Standardization (ISO) 7708 (1995) Air quality—particle size fraction definitions for health-related sampling. However, a specific sampling device is not mandated, and while several samplers have laboratory performance approaching theoretical for an ‘inhalable’ sampler, the best choice of sampler for wood dust is not clear. A side-by-side field study was considered the most practical test of samplers as laboratory performance tests consider overall performance based on a wider range of particle sizes than are commonly encountered in the wood products industry. Seven companies in the wood products industry of the Southeast USA (MS, KY, AL, and WV) participated in this study. The products included hardwood flooring, engineered hardwood flooring, door skins, shutter blinds, kitchen cabinets, plywood, and veneer. The samplers selected were 37-mm closed-face cassette with ACCU-CAP™, Button, CIP10-I, GSP, and Institute of Occupational Medicine. Approximately 30 of each possible pairwise combination of samplers were collected as personal sample sets. Paired samplers of the same type were used to calculate environmental variance that was then used to determine the number of pairs of samples necessary to detect any difference at a specified level of confidence. Total valid sample number was 888 (444 valid pairs). The mass concentration of wood dust ranged from 0.02 to 195 mg m−3. Geometric mean (geometric standard deviation) and arithmetic mean (standard deviation) of wood dust were 0.98 mg m−3 (3.06) and 2.12 mg m−3 (7.74), respectively. One percent of the samples exceeded 15 mg m−3, 6% exceeded 5 mg m−3, and 48% exceeded 1 mg m−3. The number of collected pairs is generally appropriate to detect a 35% difference when outliers (negative mass loadings) are removed. Statistical evaluation of the nonsimilar sampler pair results produced a finding of no significant difference between any pairing of sampler type. A practical consideration for sampling in the USA is that the ACCU-CAP™ is similar to the sampler currently used by the Occupational Safety and Health Administration for purposes of demonstrating compliance with its permissible exposure limit for wood dust, which is the same as for Particles Not Otherwise Regulated, also known as inert dust or nuisance dust (Method PV2121). PMID:21036895
A Physiological Approach to Prolonged Recovery From Sport-Related Concussion.
Leddy, John; Baker, John G; Haider, Mohammad Nadir; Hinds, Andrea; Willer, Barry
2017-03-01
Management of the athlete with postconcussion syndrome (PCS) is challenging because of the nonspecificity of PCS symptoms. Ongoing symptoms reflect prolonged concussion pathophysiology or conditions such as migraine headaches, depression or anxiety, chronic pain, cervical injury, visual dysfunction, vestibular dysfunction, or some combination of these. In this paper, we focus on the physiological signs of concussion to help narrow the differential diagnosis of PCS in athletes. The physiological effects of exercise on concussion are especially important for athletes. Some athletes with PCS have exercise intolerance that may result from altered control of cerebral blood flow. Systematic evaluation of exercise tolerance combined with a physical examination of the neurologic, visual, cervical, and vestibular systems can in many cases identify one or more treatable postconcussion disorders.
Harper, Martin; Pacolay, Bruce; Hintz, Patrick; Andrew, Michael E
2006-03-01
Personal and area samples for airborne lead were taken at a lead mine concentrator mill, and at a lead-acid battery recycler. Lead is mined as its sulfidic ore, galena, which is often associated with zinc and silver. The ore typically is concentrated, and partially separated, on site by crushing and differential froth flotation of the ore minerals before being sent to a primary smelter. Besides lead, zinc and iron are also present in the airborne dusts, together with insignificant levels of copper and silver, and, in one area, manganese. The disposal of used lead-acid batteries presents environmental issues, and is also a waste of recoverable materials. Recycling operations allow for the recovery of lead, which can then be sold back to battery manufacturers to form a closed loop. At the recycling facility lead is the chief airborne metal, together with minor antimony and tin, but several other metals are generally present in much smaller quantities, including copper, chromium, manganese and cadmium. Samplers used in these studies included the closed-face 37 mm filter cassette (the current US standard method for lead sampling), the 37 mm GSP or "cone" sampler, the 25 mm Institute of Occupational Medicine (IOM) inhalable sampler, the 25 mm Button sampler, and the open-face 25 mm cassette. Mixed cellulose-ester filters were used in all samplers. The filters were analyzed after sampling for their content of the various metals, particularly lead, that could be analyzed by the specific portable X-ray fluorescence (XRF) analyzer under study, and then were extracted with acid and analyzed by inductively coupled plasma optical emission spectroscopy (ICP-OES). The 25 mm filters were analyzed using a single XRF reading, while three readings on different parts of the filter were taken from the 37 mm filters. For lead at the mine concentrate mill, all five samplers gave good correlations (r2 > 0.96) between the two analytical methods over the entire range of found lead mass, which encompassed the permissible exposure limit of 150 mg m(-3) enforced in the USA by the Mine Safety and Health Administration (MSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations without additional correction, indicating an absence of matrix effects from the presence of iron and zinc in the samples. An approximately 10% negative bias was found for the slope of the Button sampler regression, in line with other studies, but it did not significantly affect the accuracy as all XRF results from this sampler were within 20% of the corresponding ICP values. As in previous studies, the best results were obtained with the GSP sampler using the average of three readings, with all XRF results within 20% of the corresponding ICP values and a slope close to 1 (0.99). Greater than 95% of XRF results were within 20% of the corresponding ICP values for the closed-face 37 mm cassette using the OSHA algorithm, and the IOM sampler using a sample area of 3.46 cm2. As in previous studies, considerable material was found on the interior walls of all samplers that possess an internal surface for deposition, at approximately the same proportion for all samplers. At the lead-acid battery recycler all five samplers in their optimal configurations gave good correlations (r2 > 0.92) between the two analytical methods over the entire range of found lead mass, which included the permissible exposure limit enforced in the USA by the Occupational Safety and Health Administration (OSHA). Linear regression on the results from most samplers gave almost 1 ratio 1 correlations (except for the Button sampler), indicating an absence of matrix effects from the presence of the smaller quantities of the other metals in the samples. A negative bias was found for the slope of the button sampler regression, in line with other studies. Even though very high concentrations of lead were encountered (up to almost 6 mg m(-3)) no saturation of the detector was observed. Most samplers performed well, with >90% of XRF results within +/- 25% of the corresponding ICP results for the optimum configurations. The OSHA algorithm for the CFC worked best without including the back-up pad with the filter.
Cho, Yeo-Myoung; Werner, David; Choi, Yongju; Luthy, Richard G
2012-03-15
The results of five years of post-treatment monitoring following in-situ activated carbon (AC) placement for stabilization of polychlorinated biphenyls (PCBs) at an inter-tidal mudflat adjacent to Hunters Point Shipyard, San Francisco Bay, CA, USA are reported in this paper. After five years, AC levels of the sediment cores were comparable to those at earlier sampling times. Passive sampler uptake validated the benefit of the AC amendment with a strong local sorbent dose-response relationship. The PCB uptakes in passive samplers decreased up to 73% with a 3.7 dry wt.% AC dose after five years, confirming the temporal enhancement of the amendment benefit from a 19% reduction with a 4.4% dose observed within one month. The long-term effectiveness of AC, the local AC dose response, the impact of fouling by NOM, the spatial heterogeneity of AC incorporation, and the effects of advective sediment pore-water movement are discussed with the aid of a PCB mass transfer model. Modeling and experimental results indicated that the homogeneous incorporation of AC in the sediment will significantly accelerate the benefit of the treatment. Copyright © 2011 Elsevier B.V. All rights reserved.
Improved Atmospheric Sampling of Hexavalent Chromium
Torkmahalleh, Mehdi Amouei; Yu, Chang-Ho; Lin, Lin; Fan, Zhihua (Tina); Swift, Julie L.; Bonanno, Linda; Rasmussen, Don H.; Holsen, Thomas M.; Hopke, Philip K.
2015-01-01
Hexavalent chromium (Cr(VI)) and trivalent chromium (Cr(III)) are the primary chromium oxidation states found in ambient atmospheric particulate matter. While Cr(III) is relatively nontoxic, Cr(VI) is toxic and exposure to Cr(VI) may lead to cancer, nasal damage, asthma, bronchitis, and pneumonitis. Accurate measurement of the ambient Cr(VI) concentrations is an environmental challenge since Cr(VI) can be reduced to Cr(III) and vice versa during sampling. In the present study, a new Cr(VI) sampler (Clarkson sampler) was designed, constructed, and field tested to improve the sampling of Cr(VI) in ambient air. The new Clarkson Cr(VI) sampler was based on the concept that deliquescence during sampling leads to aqueous phase reactions. Thus, the relative humidity of the sampled air was reduced below the deliquescence relative humidity (DRH) of the ambient particles. The new sampler was operated to collect Total Suspended Particles (TSP), and compared side-by-side with the current National Air Toxics Trends Stations (NATTS) Cr(VI) sampler that is utilized in the United States Environmental Protection Agency (USEPA) air toxics monitoring program. Side-by-side field testing of the samplers occurred in Elizabeth, NJ during the winter and summer of 2012. The average recovery values of Cr(VI) spikes after 24 hour sampling intervals during summer and winter sampling were 57 and 72%, respectively, for the Clarkson sampler, while the corresponding average values for NATTS samplers were 46% for both summer and winter sampling, respectively. Preventing the ambient aerosol collected on the filters from deliquescing is a key to improving the sampling of Cr(VI). PMID:24344574
Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study.
Weems, Shelley; Heller, Pamela; Fenton, Susan H
2015-01-01
The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: 1. Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity. 2. Coder training and type of record (inpatient versus outpatient) affect coding productivity. 3. Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity.
Results from the Veterans Health Administration ICD-10-CM/PCS Coding Pilot Study
Weems, Shelley; Heller, Pamela; Fenton, Susan H.
2015-01-01
The Veterans Health Administration (VHA) of the US Department of Veterans Affairs has been preparing for the October 1, 2015, conversion to the International Classification of Diseases, Tenth Revision, Clinical Modification and Procedural Coding System (ICD-10-CM/PCS) for more than four years. The VHA's Office of Informatics and Analytics ICD-10 Program Management Office established an ICD-10 Learning Lab to explore expected operational challenges. This study was conducted to determine the effects of the classification system conversion on coding productivity. ICD codes are integral to VHA business processes and are used for purposes such as clinical studies, performance measurement, workload capture, cost determination, Veterans Equitable Resource Allocation (VERA) determination, morbidity and mortality classification, indexing of hospital records by disease and operations, data storage and retrieval, research purposes, and reimbursement. The data collection for this study occurred in multiple VHA sites across several months using standardized methods. It is commonly accepted that coding productivity will decrease with the implementation of ICD-10-CM/PCS. The findings of this study suggest that the decrease will be more significant for inpatient coding productivity (64.5 percent productivity decrease) than for ambulatory care coding productivity (6.7 percent productivity decrease). This study reveals the following important points regarding ICD-10-CM/PCS coding productivity: Ambulatory care ICD-10-CM coding productivity is not expected to decrease as significantly as inpatient ICD-10-CM/PCS coding productivity.Coder training and type of record (inpatient versus outpatient) affect coding productivity.Inpatient coding productivity is decreased when a procedure requiring ICD-10-PCS coding is present. It is highly recommended that organizations perform their own analyses to determine the effects of ICD-10-CM/PCS implementation on coding productivity. PMID:26396553
Goyal, J; Wang, K; Liu, M; Subbaiah, P V
1997-06-27
Although the major function of lecithin-cholesterol acyltransferase (LCAT) is cholesterol esterification, our previous studies showed that it can also hydrolyze platelet-activating factor (PAF). Because of the structural similarities between PAF and the truncated phosphatidylcholines (polar PCs) generated during lipoprotein oxidation, we investigated the possibility that LCAT may also hydrolyze polar PCs to lyso-PC during the oxidation of plasma. PAF acetylhydrolase (PAF-AH), which is known to hydrolyze polar PCs in human plasma, was completely inhibited by 0.2 mM p-aminoethyl benzenesulfonyl fluoride (Pefabloc), a new serine esterase inhibitor, which had no effect on LCAT at this concentration. On the other hand, 1 mM diisopropylfluorophosphate (DFP) completely inhibited LCAT but had no effect on PAF-AH. Polar PC accumulation during the oxidation of plasma increased by 44% in the presence of 0.2 mM Pefabloc and by 30% in the presence of 1 mM DFP. The formation of lyso-PC was concomitantly inhibited by both of the inhibitors. The combination of the two inhibitors resulted in the maximum accumulation of polar PCs, suggesting that both PAF-AH and LCAT are involved in their breakdown. Oxidation of chicken plasma, which has no PAF-AH activity, also resulted in the formation of lyso-PC from the hydrolysis of polar PC, which was inhibited by DFP. Polar PCs, either isolated from oxidized plasma or by oxidation of labeled synthetic PCs, were hydrolyzed by purified LCAT, which had no detectable PAF-AH activity. These results demonstrate a novel function for LCAT in the detoxification of polar PCs generated during lipoprotein oxidation, especially when the PAF-AH is absent or inactivated.
Hall, Susan; Murchie, Peter; Campbell, Christine; Murray, Scott A
2012-10-01
An electronic Palliative Care Summary (ePCS) is currently being implemented throughout Scotland to provide out-of-hours (OOH) staff with up-to-date summaries of medical history, patient understanding and wishes, medications and decisions regarding treatment of patients requiring palliative care: automatic twice daily updates of information from GP records to a central electronic repository are available to OOH services. To identify key issues related to the introduction of ePCS from primary care and OOH staff, to identify facilitators and barriers to their use, to explore the experiences of patients and carers and to make recommendations for improvements. Twenty-two semi-structured interviews were carried out with a purposive sample of health professionals [practice nurses (3 interviews), GPs (12 interviews), a practice manager (1 interview) from practices using different computing software systems] and patients and/or carers (6 interviews for whom an ePCS had been completed). Interviews were digitally recorded, transcribed and analysed thematically. Patients and carers were reassured that OOH staff were informed about their current circumstances. OOH staff considered the ePCS allowed them to be better informed in decision making and in carrying out home visits. GPs viewed the introduction of ePCSs to have benefits for in-hours structures of care including advance care planning. No interviewee expressed concern about confidentiality. Barriers raised related to the introduction of new technology including unfamiliarity with the process, limited time and information technology skills. The ePCS has clear potential to improve patient care although several implementation issues and technical problems require to be addressed first to enable this. GPs and community nurses should identify more patients with malignant and non-malignant illnesses for completion of the ePCS.
Ritter, Katrina G; Hussey, Matthew J; Valovich McLeod, Tamara C
2017-09-27
Clinical Scenario: Patients who experience prolonged concussion symptoms can be diagnosed with Post-Concussion Syndrome (PCS) when those symptoms persist past 4 weeks. Aerobic exercise protocols have been shown to be effective in improving physical and mental aspects of health. Emerging research suggests that aerobic exercise maybe useful as a treatment for PCS, where exercise allows patients to feel less isolated and more active during the recovery process. Is aerobic exercise more beneficial in reducing symptoms than current standard care in patients with prolonged symptoms or PCS lasting longer than 4 weeks? Summary of Key Findings: After a thorough literature search, 4 studies were selected relevant to the clinical question. Of the 4 studies, 1 was a randomized control trial and 3 were case series. All 4 studies investigate aerobic exercise protocol as treatment for PCS. 1-4 Three articles demonstrated a greater rate of symptom improvement from baseline assessment to follow-up after a controlled sub-symptomatic aerobic exercise program. 2-4 One study showed a decrease in symptoms in the aerobic exercise group compared to the full body stretching group. 1 Clinical Bottom Line: There is moderate evidence to support sub-symptomatic aerobic exercise as a treatment of PCS, therefore it should be considered as a clinical option for reducing PCS and prolonged concussion symptoms. A previously validated protocol, such as the Buffalo Concussion Treadmill Test, Balke Protocol, or Rating of Perceived Exertion (RPE) as mentioned in this critically appraised topic should be used to measure baseline values and treatment progression. Strength of Recommendation: Level C evidence exists that aerobic exercise protocol is more effective than the current standard of care in treating PCS.
Sours, Chandler; Chen, Haoxing; Roys, Steven; Zhuo, Jiachen; Varshney, Amitabh; Gullapalli, Rao P
2015-09-01
The aim of this study was to investigate if discrete wavelet decomposition provides additional insight into resting-state processes through the analysis of functional connectivity within specific frequency ranges within the default mode network (DMN) that may be affected by mild traumatic brain injury (mTBI). Participants included 32 mTBI patients (15 with postconcussive syndrome [PCS+] and 17 without [PCS-]). mTBI patients received resting-state functional magnetic resonance imaging (rs-fMRI) at acute (within 10 days of injury) and chronic (6 months postinjury) time points and were compared with 31 controls (healthy control [HC]). The wavelet decomposition divides the time series into multiple frequency ranges based on four scaling factors (SF1: 0.125-0.250 Hz, SF2: 0.060-0.125 Hz, SF3: 0.030-0.060 Hz, SF4: 0.015-0.030 Hz). Within each SF, wavelet connectivity matrices for nodes of the DMN were created for each group (HC, PCS+, PCS-), and bivariate measures of strength and diversity were calculated. The results demonstrate reduced strength of connectivity in PCS+ patients compared with PCS- patients within SF1 during both the acute and chronic stages of injury, as well as recovery of connectivity within SF1 across the two time points. Furthermore, the PCS- group demonstrated greater network strength compared with controls at both time points, suggesting a potential compensatory or protective mechanism in these patients. These findings stress the importance of investigating resting-state connectivity within multiple frequency ranges; however, many of our findings are within SF1, which may overlap with frequencies associated with cardiac and respiratory activities.
A small and relatively lightweight (3.35 kg) whole-air (canister) sampler that can be worn to monitor personal exposures to volatile organic compounds was developed and evaluated. The prototype personal whole air sampler (PWAS) consists of a 1-L canister, a mass flow controller, ...
40 CFR 1065.1109 - Post-test sampler disassembly and sample extraction.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Post-test sampler disassembly and... Semi-Volatile Organic Compounds § 1065.1109 Post-test sampler disassembly and sample extraction. This... environment as follows after the test: (1) Remove the PM filter, PUF plugs, and all the XAD-2 from the...
In April 2014, U.S. Environmental Protection Agency (EPA) environmental monitoring and assessment team members reviewed DOE's air sampling plan, visited DOE's air samplers and placed air samplers onsite near existing DOE samplers to corroborate results.
Performance characteristics of a low-volume PM10 sampler
USDA-ARS?s Scientific Manuscript database
Four identical PM10 pre-separators, along with four identical low-volume (1m3 hr-1) total suspended particulate (TSP) samplers were tested side-by-side in a controlled laboratory particulate matter (PM) chamber. The four PM10 and four TSP samplers were also tested in an oil pipe-cleaning field to ev...
40 CFR 53.63 - Test procedure: Wind tunnel inlet aspiration test.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the sampler inlet opening centered in the sampling zone. To meet the maximum blockage limit of § 53.62(c)(1) or for convenience, part of the test sampler may be positioned external to the wind tunnel... = reference method sampler volumetric flow rate; and t = sampling time. (iii) Remove the reference method...
Discipline-Based Art Education: A Curriculum Sampler.
ERIC Educational Resources Information Center
Alexander, Kay, Ed.; Day, Michael, Ed.
This sampler was designed for art specialists and art museum educators with a basic understanding of teaching discipline-based art education content. The introduction offers a brief history of the Sampler and explains its intended purpose and use. Then 8 unit models with differing methodologies for relating art objectives to the four disciplines:…
50 CFR 648.11 - At-sea sea sampler/observer coverage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 50 Wildlife and Fisheries 12 2012-10-01 2012-10-01 false At-sea sea sampler/observer coverage. 648... Provisions § 648.11 At-sea sea sampler/observer coverage. (a) The Regional Administrator may request any vessel holding a permit for Atlantic sea scallops, NE multispecies, monkfish, skates, Atlantic mackerel...
The purpose of this SOP is to describe the procedures for calibrating Harvard particulate matter (PM) samplers. This procedure applies directly to the Harvard particulate matter (PM) samplers used during the Arizona NHEXAS project and the Border study. Keywords: lab; equipment;...
40 CFR 53.61 - Test conditions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test conditions. 53.61 Section 53.61... Equivalent Methods for PM2.5 § 53.61 Test conditions. (a) Sampler surface preparation. Internal surfaces of the candidate sampler shall be cleaned and dried prior to performing any Class II sampler test in this...
40 CFR 53.61 - Test conditions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test conditions. 53.61 Section 53.61... Equivalent Methods for PM2.5 § 53.61 Test conditions. (a) Sampler surface preparation. Internal surfaces of the candidate sampler shall be cleaned and dried prior to performing any Class II sampler test in this...
The Ogawa passive sampler (Ogawa USA, Pompano Beach, Florida) is a useful tool for monitoring atmospheric ammonia (NH3(g)) concentrations and assessing the effects of agricultural waste management practices on NH3(g) emissions. The Ogawa sampler, with fil...
Development and Utilization of the Regional Oceanic Modeling System (ROMS)
2008-09-30
the Peru/ Chile Current system (PCS). Emphasis is put on the PCS due to its direct connection with the equatorial region; this makes it a good...nearshore wind drop-off that occurs in reality. Numerical simulations of the Peru/ Chile (PCS) and the California (CCS) upwelling systems are being... Chile and the USWC 4. More subtle effects of the wind/SST coupling on the mesoscale eddy activity are now investigated. RESULTS Since funds for
Compact cryocooling system for HTS sampler
NASA Astrophysics Data System (ADS)
Suzuki, H.; Maruyama, M.; Hato, T.; Wakana, H.; Tanabe, K.; Konno, T.; Uekusa, K.; Sato, N.; Kawabata, M.
2007-10-01
This paper describes a compact cooling system using a single-stage stirling-type cryocooler for a practical HTS sampler. The system was designed to cool down an HTS sampler module below 50 K, enabling a bandwidth of the chip more than 100 GHz. The system measures 150 mm in width, 140 mm in height and 310 mm in depth, and weighs 5 kg. Semi-rigid coaxial cables made of brass with a silver coated inner conductor were adopted for a signal to be measured and a trigger pulse. The loss for the signal line was less than 1.5 dB at 50 GHz with relatively small thermal inflow. Thermal inflows from low frequency lines, IF signal lines for control/output of the sampler and dc bias lines, were minimized by choosing proper wires. A new sampler module with reduced weight was placed on the cold stage, which was surrounded by double magnetic shields. The module was successfully cooled down to less than 50 K with cooling time of 1 h in the system. We have also succeeded in observing sinusoidal waveforms with the HTS sampler cooled by the compact cooling system.
USGS GeoData Digital Raster Graphics
,
2001-01-01
Passive diffusion samplers have been tested at a number of sites where volatile organic compounds (VOC?s) are the principal contaminants in ground water. Test results generally show good agreement between concentrations of VOC?s in samples collected with diffusion samplers and concentrations in samples collected by purging the water from a well. Diffusion samplers offer several advantages over conventional and low-flow ground-water sampling procedures: ? Elimination of the need to purge a well before collecting a sample and to dispose of contaminated water. ? Elimination of cross-contamination of samples associated with sampling with non-dedicated pumps or sample delivery tubes. ? Reduction in sampling time by as much as 80 percent of that required for ?purge type? sampling methods. ? An increase in the frequency and spatial coverage of monitoring at a site because of the associated savings in time and money. The successful use of diffusion samplers depends on the following three primary factors: (1) understanding site conditions and contaminants of interest (defining sample objectives), (2) validating of results of diffusion samplers against more widely acknowledged sampling methods, and (3) applying diffusion samplers in the field.
Enzymatic properties and substrate specificity of a bacterial phosphatidylcholine synthase.
Aktas, Meriyem; Köster, Stefan; Kizilirmak, Sarah; Casanova, Javier C; Betz, Heidi; Fritz, Christiane; Moser, Roman; Yildiz, Özkan; Narberhaus, Franz
2014-08-01
Phosphatidylcholine (PC) is a rare membrane lipid in bacteria, but is crucial for virulence of the plant pathogen Agrobacterium tumefaciens and various other pathogens. Agrobacterium tumefaciens uses two independent PC biosynthesis pathways. One is dependent on the integral membrane protein PC synthase (Pcs), which catalyzes the conversion of cytidine diphosphate-diacylglycerol (CDP-DAG) and choline to PC, thereby releasing a cytidine monophosphate (CMP). Here, we show that Pcs consists of eight transmembrane segments with its N- and C-termini located in the cytoplasm. A cytoplasmic loop between the second and third membrane helix contains the majority of the conserved amino acids of a CDP-alcohol phosphotransferase motif (DGX2 ARX12 GX3 DX3 D). Using point mutagenesis, we provide evidence for a crucial role of this motif in choline binding and enzyme activity. To study the catalytic features of the enzyme, we established a purification protocol for recombinant Pcs. The enzyme forms stable oligomers and exhibits broad substrate specificity towards choline derivatives. The presence of CDP-DAG and manganese is a prerequisite for cooperative binding of choline. PC formation by Pcs is reversible and proceeds via two successive reactions. In a first choline- and manganese-independent reaction, CDP-DAG is hydrolyzed releasing a CMP molecule. The resulting phosphatidyl intermediate reacts with choline in a second manganese-dependent step to form PC. Pcs and Pcs bind by molecular sieving (1, 2, 3). © 2014 FEBS.
Zanini, Claudia; Maino, Paolo; Möller, Jens Carsten; Gobbi, Claudio; Raimondi, Monika; Rubinelli, Sara
2016-05-01
This study examined whether and how a pre-consultation sheet (PCS) that captures patients' views on their condition and treatments can facilitate doctors in identifying targets for medical advice. A PCS in the form of a list of questions was developed and implemented in chronic pain consultations. Its value was examined through video-recordings and post-consultation interviews with doctors and patients. Doctors reported that the PCS helped them identify topics that required further discussion with patients, unexpected information, patients' expectations on outcomes, and their attitudes and beliefs about treatments. Patients reported that the PCS helped them collect and structure their views, reduced their anxiety regarding the encounter, and created a setting in which they felt heard. The PCS captures patients' views that are valuable in helping doctors identify targets of intervention. It focuses on aspects that matter to patients and that enrich information sharing beyond medical records. Addressing patients' views on health conditions and treatments facilitates doctors and patients in defining targets for intervention. It assists doctors in tailoring their advice and helps patients present their case. A PCS seems to be a feasible and acceptable instrument to support doctors and patients in this information sharing. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lu, Tao; Peng, Wenhong; Zhu, Shenmin; Zhang, Di
2016-03-01
When the constitutive materials of photonic crystals (PCs) are stimuli-responsive, the resultant PCs exhibit optical properties that can be tuned by the stimuli. This can be exploited for promising applications in colour displays, biological and chemical sensors, inks and paints, and many optically active components. However, the preparation of the required photonic structures is the first issue to be solved. In the past two decades, approaches such as microfabrication and self-assembly have been developed to incorporate stimuli-responsive materials into existing periodic structures for the fabrication of PCs, either as the initial building blocks or as the surrounding matrix. Generally, the materials that respond to thermal, pH, chemical, optical, electrical, or magnetic stimuli are either soft or aggregate, which is why the manufacture of three-dimensional hierarchical photonic structures with responsive properties is a great challenge. Recently, inspired by biological PCs in nature which exhibit both flexible and responsive properties, researchers have developed various methods to synthesize metals and metal oxides with hierarchical structures by using a biological PC as the template. This review will focus on the recent developments in this field. In particular, PCs with biological hierarchical structures that can be tuned by external stimuli have recently been successfully fabricated. These findings offer innovative insights into the design of responsive PCs and should be of great importance for future applications of these materials.
Detoxification of Arsenic by Phytochelatins in Plants1
Schmöger, Marcus E.V.; Oven, Matjaz; Grill, Erwin
2000-01-01
As is a ubiquitous element present in the atmosphere as well as in the aquatic and terrestrial environments. Arsenite and arsenate are the major forms of As intoxication, and these anions are readily taken up by plants. Both anions efficiently induce the biosynthesis of phytochelatins (PCs) ([γ-glutamate-cysteine]n-glycine) in vivo and in vitro. The rapid induction of the metal-binding PCs has been observed in cell suspension cultures of Rauvolfia serpentina, in seedlings of Arabidopsis, and in enzyme preparations of Silene vulgaris upon challenge to arsenicals. The rate of PC formation in enzyme preparations was lower compared with Cd-induced biosynthesis, but was accompanied by a prolonged induction phase that resulted finally in higher peptide levels. An approximately 3:1 ratio of the sulfhydryl groups from PCs to As is compatible with reported As-glutathione complexes. The identity of the As-induced PCs and of reconstituted metal-peptide complexes has unequivocally been demonstrated by electrospray ionization mass spectroscopy. Gel filtration experiments and inhibitor studies also indicate a complexation and detoxification of As by the induced PCs. PMID:10712543
Oluwole, David O; Sarı, Fatma Aslıhan; Prinsloo, Earl; Dube, Edith; Yuzer, Abdulcelil; Nyokong, Tebello; Ince, Mine
2018-05-29
The syntheses of two zinc(II) phthalocyanines (ZnPcs) having either imidazole (ZnPc 1) or pyridiloxy (ZnPc 2) moieties as their macrocycle substituents are reported. Quaternization of the ZnPcs with methyl iodide afforded water soluble cationic phthalocyanines. The photophysical, photochemical properties and photodynamic therapy (PDT) activity of the ZnPcs were studied in solution. The fluorescence quantum yield and lifetime of ZnPc 1 were higher as compared to ZnPc 2. ZnPc 2 afforded higher triplet state (Φ T ) and singlet oxygen quantum yields (Φ Δ ) in comparison to ZnPc 1. The PDT activity of ZnPcs was investigated against human breast adenocarcinoma cells (MCF-7). The two compounds afforded a very minimal in vitro dark cytotoxicity with 85% viable cells at concentration ≤80 μM. On irradiation of the cells having the ZnPcs, ≥50% cell death was recorded for ZnPc 1 which was also evidenced by the cells photo-micrograph. Copyright © 2018 Elsevier B.V. All rights reserved.
Stochastic optimization of broadband reflecting photonic structures.
Estrada-Wiese, D; Del Río-Chanona, E A; Del Río, J A
2018-01-19
Photonic crystals (PCs) are built to control the propagation of light within their structure. These can be used for an assortment of applications where custom designed devices are of interest. Among them, one-dimensional PCs can be produced to achieve the reflection of specific and broad wavelength ranges. However, their design and fabrication are challenging due to the diversity of periodic arrangement and layer configuration that each different PC needs. In this study, we present a framework to design high reflecting PCs for any desired wavelength range. Our method combines three stochastic optimization algorithms (Random Search, Particle Swarm Optimization and Simulated Annealing) along with a reduced space-search methodology to obtain a custom and optimized PC configuration. The optimization procedure is evaluated through theoretical reflectance spectra calculated by using the Equispaced Thickness Method, which improves the simulations due to the consideration of incoherent light transmission. We prove the viability of our procedure by fabricating different reflecting PCs made of porous silicon and obtain good agreement between experiment and theory using a merit function. With this methodology, diverse reflecting PCs can be designed for any applications and fabricated with different materials.
Physicians’ Outlook on ICD-10-CM/PCS and Its Effect on Their Practice
Watzlaf, Valerie; Alkarwi, Zahraa; Meyers, Sandy; Sheridan, Patty
2015-01-01
Background The United States is one of the last countries to change from ICD-9-CM to ICD-10-CM/PCS. The compliance date for implementation of ICD-10-CM/PCS is expected to fall on October 1, 2015. Objectives Evaluate physicians’ perceptions on the change from ICD-9-CM to ICD-10-CM/PCS and its effect on their practice, determine how HIM professionals can assist in this transition, and assess what resources are needed to aid in the transition. Results Twenty physicians were asked to participate in one of three focus groups. Twelve physicians (60 percent) agreed to participate. Top concerns included electronic health record software readiness, increase in documentation specificity and time, ability of healthcare professionals to learn a new language, and inadequacy of current training methods and content. Conclusion Physicians expressed that advantages of ICD-10-CM/PCS were effective data analytics and complexity of patient cases with more specific codes. Health information management professionals were touted as needed during the transition to create simple, clear specialty guides and crosswalks as well as education and training tools specific for physicians. PMID:26807074
DOE Office of Scientific and Technical Information (OSTI.GOV)
Halbgewachs, Ronald D.; Chavez, Adrian R.
Process Control System (PCS) and Industrial Control System (ICS) security is critical to our national security. But there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. Sandia National Laboratories has performed the research and development of the OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy Office of Electricity Delivery and Energy Reliability (DOE/OE), to address this issue. OPSAID is an open-source architecture for PCS/ICS security that provides a design basis for vendors to build add-on security devices for legacy systems, whilemore » providing a path forward for the development of inherently-secure PCS elements in the future. Using standardized hardware, a proof-of-concept prototype system was also developed. This report describes the improvements and capabilities that have been added to OPSAID since an initial report was released. Testing and validation of this architecture has been conducted in another project, Lemnos Interoperable Security Project, sponsored by DOE/OE and managed by the National Energy Technology Laboratory (NETL).« less
Conceptual Design of the ITER Plasma Control System
NASA Astrophysics Data System (ADS)
Snipes, J. A.
2013-10-01
The conceptual design of the ITER Plasma Control System (PCS) has been approved and the preliminary design has begun for the 1st plasma PCS. This is a collaboration of many plasma control experts from existing devices to design and test plasma control techniques applicable to ITER on existing machines. The conceptual design considered all phases of plasma operation, ranging from non-active H/He plasmas through high fusion gain inductive DT plasmas to fully non-inductive steady-state operation, to ensure that the PCS control functionality and architecture can satisfy the demands of the ITER Research Plan. The PCS will control plasma equilibrium and density, plasma heat exhaust, a range of MHD instabilities (including disruption mitigation), and the non-inductive current profile required to maintain stable steady-state scenarios. The PCS architecture requires sophisticated shared actuator management and event handling systems to prioritize control goals, algorithms, and actuators according to dynamic control needs and monitor plasma and plant system events to trigger automatic changes in the control algorithms or operational scenario, depending on real-time operating limits and conditions.
Comparison of surfactant lipids between pleural and pulmonary lining fluids.
Mills, P C; Chen, Y; Hills, Y C; Hills, B A
2006-01-01
Saturated phospholipids (PCs), particularly dipalmitoylphosphatidylcholine (DPPC), predominate in surfactant lining the alveoli, although little is known about the relationship between saturated and unsaturated PCs on the outer surface of the lung, the pleura. Seven healthy cats were anesthetized and a bronchoalveolar lavage (BAL) was performed, immediately followed by a pleural lavage (PL). Lipid was extracted from lavage fluid and then analyzed for saturated, primarily dipalmitoylphosphatidylcholine (DPPC), and unsaturated PC species using high-performance liquid chromatography (HPLC) with combined fluorescence and ultraviolet detection. Dilution of epithelial lining fluid (ELF) in lavage fluids was corrected for using the urea method. The concentration of DPPC in BAL fluid (85.3+/-15.7 microg/mL) was significantly higher (P=0.021) than unsaturated PCs ( approximately 40 microg/mL). However, unsaturated PCs ( approximately 34 microg/mL), particularly stearoyl-linoleoyl-phosphatidylcholine (SLPC; 17.4+/-6.8), were significantly higher (P=0.021) than DPPC (4.3+/-1.8 microg/mL) in PL fluid. These results show that unsaturated PCs appear functionally more important in the pleural cavity, which may have implications for surfactant replenishment following pleural disease or thoracic surgery.
Self Organization in Compensated Semiconductors
NASA Astrophysics Data System (ADS)
Berezin, Alexander A.
2004-03-01
In partially compensated semiconductor (PCS) Fermi level is pinned to donor sub-band. Due to positional randomness and almost isoenergetic hoppings, donor-spanned electronic subsystem in PCS forms fluid-like highly mobile collective state. This makes PCS playground for pattern formation, self-organization, complexity emergence, electronic neural networks, and perhaps even for origins of life, bioevolution and consciousness. Through effects of impact and/or Auger ionization of donor sites, whole PCS may collapse (spinodal decomposition) into microblocks potentially capable of replication and protobiological activity (DNA analogue). Electronic screening effects may act in RNA fashion by introducing additional length scale(s) to system. Spontaneous quantum computing on charged/neutral sites becomes potential generator of informationally loaded microstructures akin to "Carl Sagan Effect" (hidden messages in Pi in his "Contact") or informational self-organization of "Library of Babel" of J.L. Borges. Even general relativity effects at Planck scale (R.Penrose) may affect the dynamics through (e.g.) isotopic variations of atomic mass and local density (A.A.Berezin, 1992). Thus, PCS can serve as toy model (experimental and computational) at interface of physics and life sciences.
NASA Astrophysics Data System (ADS)
Mitrofanov, K. N.; Krauz, V. I.; Grabovski, E. V.; Myalton, V. V.; Vinogradov, V. P.; Paduch, M.; Scholz, M.; Karpiński, L.
2015-05-01
The main stages of the plasma current sheath (PCS) dynamics on two plasma focus (PF) facilities with different geometries of the electrode system, PF-3 (Filippov type) and PF-1000 (Mather type), were studied by analyzing the results of the current and voltage measurements. Some dynamic characteristics, such as the PCS velocity in the acceleration phase in the Mather-type facility (PF-1000), the moment at which the PCS reaches the anode end, and the plasma velocity in the radial stage of plasma compression in the PF-3 Filippov-type facility, were determined from the time dependence of the inductance of the discharge circuit with a dynamic plasma load. The energy characteristics of the discharge circuit of the compressing PCS were studied for different working gases (deuterium, argon, and neon) at initial pressures of 1.5-3 Torr in discharges with energies of 0.3-0.6 MJ. In experiments with deuterium, correlation between the neutron yield and the electromagnetic energy deposited directly in the compressed PCS was investigated.
A Physiological Approach to Prolonged Recovery From Sport-Related Concussion
Leddy, John; Baker, John G.; Haider, Mohammad Nadir; Hinds, Andrea; Willer, Barry
2017-01-01
Management of the athlete with postconcussion syndrome (PCS) is challenging because of the nonspecificity of PCS symptoms. Ongoing symptoms reflect prolonged concussion pathophysiology or conditions such as migraine headaches, depression or anxiety, chronic pain, cervical injury, visual dysfunction, vestibular dysfunction, or some combination of these. In this paper, we focus on the physiological signs of concussion to help narrow the differential diagnosis of PCS in athletes. The physiological effects of exercise on concussion are especially important for athletes. Some athletes with PCS have exercise intolerance that may result from altered control of cerebral blood flow. Systematic evaluation of exercise tolerance combined with a physical examination of the neurologic, visual, cervical, and vestibular systems can in many cases identify one or more treatable postconcussion disorders. PMID:28387557
Kepler Reliability and Occurrence Rates
NASA Astrophysics Data System (ADS)
Bryson, Steve
2016-10-01
The Kepler mission has produced tables of exoplanet candidates (``KOI table''), as well as tables of transit detections (``TCE table''), hosted at the Exoplanet Archive (http://exoplanetarchive.ipac.caltech.edu). Transit detections in the TCE table that are plausibly due to a transiting object are selected for inclusion in the KOI table. KOI table entries that have not been identified as false positives (FPs) or false alarms (FAs) are classified as planet candidates (PCs, Mullally et al. 2015). A subset of PCs have been confirmed as planetary transits with greater than 99% probability, but most PCs have <99% probability of being true planets. The fraction of PCs that are true transiting planets is the PC reliability rate. The overall PC population is believed to have a reliability rate >90% (Morton & Johnson 2011).
The DIII-D Plasma Control System as a Scientific Research Tool
NASA Astrophysics Data System (ADS)
Hyatt, A. W.; Ferron, J. R.; Humphreys, D. A.; Leuer, J. A.; Walker, M. L.; Welander, A. S.
2006-10-01
The digital plasma control system (PCS) is an essential element of the DIII-D tokamak as a scientific research instrument, providing experimenters with real-time measurement and control of the plasma equilibrium, heating, current drive, transport, stability, and plasma-wall interactions. A wide range of sensors and actuators allow feedback control not only of global quantities such as discharge shape, plasma energy, and toroidal rotation, but also of non-axisymmetric magnetic fields and features of the internal profiles of temperature and current density. These diverse capabilities of the PCS improve the effectiveness of tokamak operation and enable unique physics experiments. We will present an overview of the PCS and the systems it controls and interacts with, and show examples of various plasma parameters controlled by the PCS and its actuators.
Dada, Shakila; Huguet, Alice; Bornman, Juan
2013-12-01
The purpose of this study was to examine the iconicity of 16 Picture Communication Symbols (PCS) presented on a themed bed-making communication overlay for South African children with English as an additional language and mild intellectual disability. The survey involved 30 participants. The results indicated that, overall, the 16 symbols were relatively iconic to the participants. The authors suggest that the iconicity of picture symbols could be manipulated, enhanced, and influenced by contextual effects (other PCS used simultaneously on the communication overlay). In addition, selection of non-target PCS for target PCS were discussed in terms of postulated differences in terms of distinctiveness. Potential clinical implications and limitations of the study, as well as recommendations for future research, are discussed.
Bataille, Stanislas; Pelletier, Marion; Sallée, Marion; Berland, Yvon; McKay, Nathalie; Duval, Ariane; Gentile, Stéphanie; Mouelhi, Yosra; Brunet, Philippe; Burtey, Stéphane
2017-07-26
The main reason for anemia in renal failure patients is the insufficient erythropoietin production by the kidneys. Beside erythropoietin deficiency, in vitro studies have incriminated uremic toxins in the pathophysiology of anemia but clinical data are sparse. In order to assess if indole 3-acetic acid (IAA), indoxyl sulfate (IS), and paracresyl sulfate (PCS) -three protein bound uremic toxins- are clinically implicated in end-stage renal disease anemia we studied the correlation between IAA, IS and PCS plasmatic concentrations with hemoglobin and Erythropoietin Stimulating Agents (ESA) use in hemodialysis patients. Between June and July 2014, we conducted an observational cross sectional study in two hemodialysis center. Three statistical approaches were conducted. First, we compared patients treated with ESA and those not treated. Second, we performed linear regression models between IAA, IS, and PCS plasma concentrations and hemoglobin, the ESA dose over hemoglobin ratio (ESA/Hemoglobin) or the ESA resistance index (ERI). Third, we used a polytomous logistic regression model to compare groups of patients with no/low/high ESA dose and low/high hemoglobin statuses. Overall, 240 patients were included in the study. Mean age ± SD was 67.6 ± 16.0 years, 55.4% were men and 42.5% had diabetes mellitus. When compared with ESA treated patients, patients with no ESA had higher hemoglobin (mean 11.4 ± 1.1 versus 10.6 ± 1.2 g/dL; p <0.001), higher transferrin saturation (TSAT, 31.1 ± 16.3% versus 23.1 ± 11.5%; p < 0.001), less frequently an IV iron prescription (52.1 versus 65.7%, p = 0.04) and were more frequently treated with hemodiafiltration (53.5 versus 36.7%). In univariate analysis, IAA, IS or PCS plasma concentrations did not differ between the two groups. In the linear model, IAA plasma concentration was not associated with hemoglobin, but was negatively associated with ESA/Hb (p = 0.02; R = 0.18) and with the ERI (p = 0.03; R = 0.17). IS was associated with none of the three anemia parameters. PCS was positively associated with hemoglobin (p = 0.03; R = 0.14), but negatively with ESA/Hb (p = 0.03; R = 0.17) and the ERI (p = 0.02; R = 0.19). In multivariate analysis, the association of IAA concentration with ESA/Hb or ERI was not statistically significant, neither was the association of PCS with ESA/Hb or ERI. Identically, in the subgroup of 76 patients with no inflammation (CRP <5 mg/L) and no iron deficiency (TSAT >20%) linear regression between IAA, IS or PCS and any anemia parameter did not reach significance. In the third model, univariate analysis showed no intergroup significant differences for IAA and IS. Regarding PCS, the Low Hb/High ESA group had lower concentrations. However, when we compared PCS with the other significant characteristics of the five groups to the Low Hb/high ESA (our reference group), the polytomous logistic regression model didn't show any significant difference for PCS. In our study, using three different statistical models, we were unable to show any correlation between IAA, IS and PCS plasmatic concentrations and any anemia parameter in hemodialysis patients. Indolic uremic toxins and PCS have no or a very low effect on anemia parameters.
A field evaluation of a SO 2 passive sampler in tropical industrial and urban air
NASA Astrophysics Data System (ADS)
Cruz, Lícia P. S.; Campos, Vânia P.; Silva, Adriana M. C.; Tavares, Tania M.
Passive samplers have been widely used for over 30 years in the measurement of personal exposure to vapours and gases in the workplace. These samplers have just recently been applied in the monitoring of ambient air, which presents concentrations that are normally much smaller than those found in occupational environments. The locally constructed passive sampler was based on gas molecular diffusion through static air layer. The design used minimizes particle interference and turbulent diffusion. After exposure, the SO 2 trapped in impregnated filters with Na 2CO 3 was extracted by means of an ultrasonic bath, for 15 min, using 1.0×10 -2 mol L -1 H 2O 2. It was determined as SO 4-2 by ion chromatography. The performance of the passive sampler was evaluated at different exposure periods, being applied in industrial and urban areas. Method precision as relative standard deviation for three simultaneously applied passive samplers was within 10%. Passive sampling, when compared to active monitoring methods under real conditions, used in urban and industrial areas, showed an overall accuracy of 15%. A statistical comparison with an active method was performed to demonstrate the validity of the passive method. Sampler capacity varied between 98 and 421 μg SO 2 m -3 for exposure periods of one month and one week, respectively, which allows its use in highly polluted areas.
NASA Astrophysics Data System (ADS)
Slanina, J.; Möls, J. J.; Baard, J. H.
The results of a wet deposition monitoring experiment, carried out by eight identical wet-only precipitation samplers operating on the basis of 24 h samples, have been used to investigate the accuracy and uncertainties in wet deposition measurements. The experiment was conducted near Lelystad, The Netherlands over the period 1 March 1983-31 December 1985. By rearranging the data for one to eight samplers and sampling periods of 1 day to 1 month both systematic and random errors were investigated as a function of measuring strategy. A Gaussian distribution of the results was observed. Outliers, detected by a Dixon test ( a = 0.05) influenced strongly both the yearly averaged results and the standard deviation of this average as a function of the number of samplers and the length of the sampling period. The systematic bias in bulk elements, using one sampler, varies typically from 2 to 20% and for trace elements from 10 to 500%, respectively. Severe problems are encountered in the case of Zn, Cu, Cr, Ni and especially Cd. For the sensitive detection of trends generally more than one sampler per measuring station is necessary as the standard deviation in the yearly averaged wet deposition is typically 10-20% relative for one sampler. Using three identical samplers, trends of, e.g. 3% per year will be generally detected in 6 years.
Characterization of five passive sampling devices for monitoring of pesticides in water.
Ahrens, Lutz; Daneshvar, Atlasi; Lau, Anna E; Kreuger, Jenny
2015-07-31
Five different passive sampler devices were characterized under laboratory conditions for measurement of 124 legacy and current used pesticides in water. In addition, passive sampler derived time-weighted average (TWA) concentrations were compared to time-integrated active sampling in the field. Sampling rates (RS) and passive sampler-water partition coefficients (KPW) were calculated for individual pesticides using silicone rubber (SR), polar organic chemical integrative sampler (POCIS)-A, POCIS-B, Chemcatcher(®) SDB-RPS and Chemcatcher(®) C18. The median RS (Lday(-1)) decreased as follows: SR (0.86)>POCIS-B (0.22)>POCIS-A (0.18)>Chemcatcher(®) SDB-RPS (0.05)>Chemcatcher(®) C18 (0.02), while the median logKPW (Lkg(-1)) decreased as follows: POCIS-B (4.78)>POCIS-A (4.56)>Chemcatcher(®) SDB-RPS (3.17)>SR (3.14)>Chemcatcher(®)C18 (2.71). The uptake of the selected compounds depended on their physicochemical properties, i.e. SR showed a better uptake for more hydrophobic compounds (log octanol-water partition coefficient (KOW)>5.3), whereas POCIS-A, POCIS-B and Chemcatcher(®) SDB-RPS were more suitable for hydrophilic compounds (logKOW<0.70). Overall, the comparison between passive sampler and time-integrated active sampler concentrations showed a good agreement and the tested passive samplers were suitable for capturing compounds with a wide range of KOW's in water. Copyright © 2015 Elsevier B.V. All rights reserved.
Computational fluid dynamics (CFD) simulation of a newly designed passive particle sampler.
Sajjadi, H; Tavakoli, B; Ahmadi, G; Dhaniyala, S; Harner, T; Holsen, T M
2016-07-01
In this work a series of computational fluid dynamics (CFD) simulations were performed to predict the deposition of particles on a newly designed passive dry deposition (Pas-DD) sampler. The sampler uses a parallel plate design and a conventional polyurethane foam (PUF) disk as the deposition surface. The deposition of particles with sizes between 0.5 and 10 μm was investigated for two different geometries of the Pas-DD sampler for different wind speeds and various angles of attack. To evaluate the mean flow field, the k-ɛ turbulence model was used and turbulent fluctuating velocities were generated using the discrete random walk (DRW) model. The CFD software ANSYS-FLUENT was used for performing the numerical simulations. It was found that the deposition velocity increased with particle size or wind speed. The modeled deposition velocities were in general agreement with the experimental measurements and they increased when flow entered the sampler with a non-zero angle of attack. The particle-size dependent deposition velocity was also dependent on the geometry of the leading edge of the sampler; deposition velocities were more dependent on particle size and wind speeds for the sampler without the bend in the leading edge of the deposition plate, compared to a flat plate design. Foam roughness was also found to have a small impact on particle deposition. Copyright © 2016 Elsevier Ltd. All rights reserved.
Pesticide monitoring in surface water and groundwater using passive samplers
NASA Astrophysics Data System (ADS)
Kodes, V.; Grabic, R.
2009-04-01
Passive samplers as screening devices have been used within a czech national water quality monitoring network since 2002 (SPMD and DGT samplers for non polar substances and metals). The passive sampler monitoring of surface water was extended to polar substances, in 2005. Pesticide and pharmaceutical POCIS samplers have been exposed in surface water at 21 locations and analysed for polar pesticides, perfluorinated compounds, personal care products and pharmaceuticals. Pesticide POCIS samplers in groundwater were exposed at 5 locations and analysed for polar pesticides. The following active substances of plant protection products were analyzed in surface water and groundwater using LC/MS/MS: 2,4,5-T, 2,4-D, Acetochlor, Alachlor, Atrazine, Atrazine_desethyl, Azoxystrobin, Bentazone, Bromacil, Bromoxynil, Carbofuran, Clopyralid, Cyanazin, Desmetryn, Diazinon, Dicamba, Dichlobenil, Dichlorprop, Dimethoat, Diuron, Ethofumesate, Fenarimol, Fenhexamid, Fipronil, Fluazifop-p-butyl, Hexazinone, Chlorbromuron, Chlorotoluron, Imazethapyr, Isoproturon, Kresoxim-methyl, Linuron, MCPA, MCPP, Metalaxyl, Metamitron, Methabenzthiazuron, Methamidophos, Methidathion, Metobromuron, Metolachlor, Metoxuron, Metribuzin, Monolinuron, Nicosulfuron, Phorate, Phosalone, Phosphamidon, Prometryn, Propiconazole, Propyzamide, Pyridate, Rimsulfuron, Simazine, Tebuconazole, Terbuthylazine, Terbutryn, Thifensulfuron-methyl, Thiophanate-methyl and Tri-allate. The POCIS samplers performed very well being able to provide better picture than grab samples. The results show that polar pesticides and also perfluorinated compounds, personal care products and pharmaceuticals as well occur in hydrosphere of the Czech republic. Acknowledgment: Authors acknowledge the financial support of grant No. 2B06095 by the Ministry of Education, Youth and Sports.
Bakó-Biró, Z; Wargocki, P; Weschler, C J; Fanger, P O
2004-06-01
In groups of six, 30 female subjects were exposed for 4.8 h in a low-polluting office to each of two conditions--the presence or absence of 3-month-old personal computers (PCs). These PCs were placed behind a screen so that they were not visible to the subjects. Throughout the exposure the outdoor air supply was maintained at 10 l/s per person. Under each of the two conditions the subjects performed simulated office work using old low-polluting PCs. They also evaluated the air quality and reported Sick Building Syndrome (SBS) symptoms. The PCs were found to be strong indoor pollution sources, even after they had been in service for 3 months. The sensory pollution load of each PC was 3.4 olf, more than three times the pollution of a standard person. The presence of PCs increased the percentage of people dissatisfied with the perceived air quality from 13 to 41% and increased by 9% the time required for text processing. Chemical analyses were performed to determine the pollutants emitted by the PCs. The most significant chemicals detected included phenol, toluene, 2-ethylhexanol, formaldehyde, and styrene. The identified compounds were, however, insufficient in concentration and kind to explain the observed adverse effects. This suggests that chemicals other than those detected, so-called 'stealth chemicals', may contribute to the negative effects. PCs are an important, but hitherto overlooked, source of pollution indoors. They can decrease the perceived air quality, increase SBS symptoms and decrease office productivity. The ventilation rate in an office with a 3-month-old PC would need to be increased several times to achieve the same perceived air quality as in a low-polluting office with the PC absent. Pollution from PCs has an important negative impact on the air quality, not only in offices but also in many other spaces, including homes. PCs may have played a role in previously published studies on SBS and perceived air quality, where PCs were overlooked as a possible pollution source in the indoor environment. The fact that the chemicals identified in the office air and in the chamber experiments were insufficient to explain the adverse effects observed during human exposures illustrates the inadequacy of the analytical chemical methods commonly used in indoor air quality investigations. For certain chemicals the human senses are much more sensitive than the chemical methods routinely used in indoor air quality investigations. The adverse effects of PC-generated air pollutants could be reduced by modifications in the manufacturing process, increased ventilation, localized PC exhaust, or personalized ventilation systems.
Comet sample acquisition for ROSETTA lander mission
NASA Astrophysics Data System (ADS)
Marchesi, M.; Campaci, R.; Magnani, P.; Mugnuolo, R.; Nista, A.; Olivier, A.; Re, E.
2001-09-01
ROSETTA/Lander is being developed with a combined effort of European countries, coordinated by German institutes. The commitment for such a challenging probe will provide a unique opportunity for in-situ analysis of a comet nucleus. The payload for coring, sampling and investigations of comet materials is called SD2 (Sampling Drilling and Distribution). The paper presents the drill/sampler tool and the sample transfer trough modeling, design and testing phases. Expected drilling parameters are then compared with experimental data; limited torque consumption and axial thrust on the tool constraint the operation and determine the success of tests. Qualification campaign involved the structural part and related vibration test, the auger/bit parts and drilling test, and the coring mechanism with related sampling test. Mechanical check of specimen volume is also reported, with emphasis on the measurement procedure and on the mechanical unit. The drill tool and all parts of the transfer chain were tested in the hypothetical comet environment, charcterized by frozen material at extreme low temperature and high vacuum (-160°C, 10-3 Pa).
A partial differential equation for pseudocontact shift.
Charnock, G T P; Kuprov, Ilya
2014-10-07
It is demonstrated that pseudocontact shift (PCS), viewed as a scalar or a tensor field in three dimensions, obeys an elliptic partial differential equation with a source term that depends on the Hessian of the unpaired electron probability density. The equation enables straightforward PCS prediction and analysis in systems with delocalized unpaired electrons, particularly for the nuclei located in their immediate vicinity. It is also shown that the probability density of the unpaired electron may be extracted, using a regularization procedure, from PCS data.
The Effects of Military Change-of-Station Moves on Spousal Earnings
2016-12-02
who experienced a PCS move with the data of military spouses who did not move but were similar in other ways, including sex , age, rural or urban...location, number and age of children , servicemember rank and education, and many other factors. Findings This study elicited a number of findings... children under the age of 6 are particu- larly adversely impacted by PCS moves. Figure 2 shows how, in the year of the PCS move, spouses with young
Analyzing Benefits of Extending the PCS Tempo in the Marine Corps
2011-12-01
voice the general consensus about the PCS process in the Marine Corps. Heartfelt thanks to my mother , brothers, and sisters. I would not be who I am...stress at home, and if so, how do they feel about the PCS process and its effect on the following aspects of family life ? a. Spouse higher education...between team effectiveness and the satisfaction level and well-being of team members. Third, a relation also exists between the team survivability
NASA Technical Reports Server (NTRS)
Hayase, Joshua Y.
1995-01-01
Reliable signaling information transfer is fundamental in supporting the needs of data communication PCS via LMS (Land Mobile Service) SSs (satellite systems). The needs of the system designer can be satisfied only through the collection of media information that can be brought to bear on the pertinent design issues. We at ISI hope to continue our dialogue with fading media experts to address the unique data communications needs of PCS via LMS SSs.
A new model for bed load sampler calibration to replace the probability-matching method
Robert B. Thomas; Jack Lewis
1993-01-01
In 1977 extensive data were collected to calibrate six Helley-Smith bed load samplers with four sediment particle sizes in a flume at the St. Anthony Falls Hydraulic Laboratory at the University of Minnesota. Because sampler data cannot be collected at the same time and place as ""true"" trap measurements, the ""probability-matching...
50 CFR 260.57 - How samples are drawn by inspectors or licensed samplers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false How samples are drawn by inspectors or... drawn by inspectors or licensed samplers. An inspector or a licensed sampler shall select samples, upon... representative sample of the lot. Samples drawn for inspection shall be furnished by the applicant at no cost to...
This paper describes the development and field evaluation of a compact high-volume dichotomous sampler (HVDS) that collects coarse (PM10-2.5) and fine (PM2.5) particulate matter. In its primary configuration as tested, the sampler size-fractionates PM10 into...
47 CFR 24.249 - Payment issues.
Code of Federal Regulations, 2013 CFR
2013-10-01
... SERVICES Broadband PCS Policies Governing Microwave Relocation from the 1850-1990 Mhz Band § 24.249 Payment... directly to the PCS relocator or the voluntarily relocating microwave incumbent the amount owed within...
47 CFR 24.249 - Payment issues.
Code of Federal Regulations, 2014 CFR
2014-10-01
... SERVICES Broadband PCS Policies Governing Microwave Relocation from the 1850-1990 Mhz Band § 24.249 Payment... directly to the PCS relocator or the voluntarily relocating microwave incumbent the amount owed within...
47 CFR 24.249 - Payment issues.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SERVICES Broadband PCS Policies Governing Microwave Relocation from the 1850-1990 Mhz Band § 24.249 Payment... directly to the PCS relocator or the voluntarily relocating microwave incumbent the amount owed within...
47 CFR 24.249 - Payment issues.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SERVICES Broadband PCS Policies Governing Microwave Relocation from the 1850-1990 Mhz Band § 24.249 Payment... directly to the PCS relocator or the voluntarily relocating microwave incumbent the amount owed within...
NASA Astrophysics Data System (ADS)
Wu, S.; Ding, K.; Yang, C.; Seyfried, W. E., Jr.; Tan, C.; Schaen, A. T.; Luhmann, A. J.
2014-12-01
A 6-bottle serial gas-tight sampler (so-called "six-shooter") was developed for application with deep-sea vent fluids. The new device is composed of a custom-made 6-channel valve manifold and six sampling bottles which are circularly distributed around the valve manifold. Each valve channel consists of a high-pressure titanium cartridge valve and a motor-driven actuator. A sampling snorkel is connected to the inlet of the manifold that delivers the incoming fluid to different bottles. Each sampling bottle has a 160 ml-volume chamber and an accumulator chamber inside where compressed nitrogen is used to maintain the sample at near in-situ pressure. An electronics chamber that is located at the center of the sampler is used to carry out all sampling operations, autonomously, if desired. The sampler is of a compact circular configuration with a diameter of 26 cm and a length of 54 cm. During the SVC cruise AT 26-12, the sampler was deployed by DSV2 Alvin at a cold seep site MC036 with a depth of 1090 m in the Gulf of Mexico. The sampler collected fluid samples automatically following the tidal cycle to monitor the potential impact of the tide cycle on the fluid chemistry of cold seep in a period of two day. During the cruise AT 26-17, the sampler was used with newly upgraded DSV2 Alvin three times at the hydrothermal vent sites along Axial Seamount and Main Endeavor Field on Juan de Fuca Ridge. During a 4-day deployment at Anemone diffuse site (Axial Caldera), the sampler was set to work in an autonomous mode to collect fluid samples according to the preset interval. During other dives, the sampler was manually controlled via ICL (Inductively Coupled Link) communication through the hull. Gas-tight fluid samples were collected from different hydrothermal vents with temperatures between 267 ℃ and 335 ℃ at the depth up to 2200 m. The field results indicate unique advantages of the design. It can be deployed in extended time period with remote operation or working autonomously taking gas-tight fluid samples. If used with HOV or ROV, it will reduce basket space occupation and ICL communication cables compared to traditional single-bottle gas-tight samplers. This time serial gas-tight fluid sampler will be further developed into a 36 bottle system for remote operation with seafloor cabled observatory.
Vestibulo-ocular dysfunction in pediatric sports-related concussion.
Ellis, Michael J; Cordingley, Dean; Vis, Sara; Reimer, Karen; Leiter, Jeff; Russell, Kelly
2015-09-01
The objective of this study was 2-fold: 1) to examine the prevalence of vestibulo-ocular dysfunction (VOD) among children and adolescents with acute sports-related concussion (SRC) and postconcussion syndrome (PCS) who were referred to a multidisciplinary pediatric concussion program; and 2) to determine if VOD is associated with the development of PCS in this cohort. The authors conducted a retrospective review of all patients with acute SRC (presenting 30 days or less postinjury) and PCS (3 or more symptoms for at least 1 month) referred to a multidisciplinary pediatric concussion program between September 2013 and July 2014. Initial assessment included clinical history, physical examination, and Post-Concussion Symptom Scale assessment. Patients were also assessed for VOD, which was defined as more than one subjective vestibular and oculomotor complaint (dizziness, blurred vision, and so on) and more than one objective physical examination finding (abnormal smooth pursuits, saccades, vestibulo-ocular reflex, and so on). This study was approved by the local institutional ethics review board. A total of 101 patients (mean age 14.2 years, SD 2.3 years; 63 male and 38 female patients) participated, including 77 (76.2%) with acute SRC and 24 (23.8%) with PCS. Twenty-two of the 77 patients (28.6%) with acute SRC and 15 of the 24 (62.5%) with PCS met the clinical criteria for VOD. The median duration of symptoms was 40 days (interquartile range [IQR] 28.5-54 days) for patients with acute SRC who had VOD compared with 21 days (IQR 13-32 days) for those without VOD (p = 0.0001). There was a statistically significant increase in the adjusted odds of developing PCS among patients with acute SRC who had VOD compared with those without VOD (adjusted OR 4.10; 95% CI 1.04-16.16). Evidence of VOD was detected in a significant proportion of children and adolescents with acute SRC and PCS who were referred to a multidisciplinary pediatric concussion program. This clinical feature was a significant risk factor for the subsequent development of PCS in this pediatric acute SRC cohort.
Functional recovery patterns in seriously injured automotive crash victims.
McMurry, Timothy L; Poplin, Gerald S; Crandall, Jeff
2016-09-01
The functional capacity index (FCI) is designed to predict functional loss 12 months post-injury for each injury in the 2008 Abbreviated Injury Scale (AIS) manual on a scale from 0 (death) to 100 (full recovery), but FCI has never been validated. This study compared FCI predicted loss with patient-reported 12-month outcomes as measured through the Short Form 36 (SF-36) health assessment survey. Using follow-up data collected on 2,858 adult car crash occupants in the Crash Injury Research and Engineering Network (CIREN) database, we compared FCI predicted outcomes to occupants' Physical Component Summary (PCS) scores, which are weighted averages of the SF-36 items addressing physical function. Our analyses included descriptive statistics, plots of typical recovery patterns, and a mixed effects regression model that describes PCS as a function of FCI, demographics, comorbidities, and injury pattern while also adjusting for the occupants' pre-crash physical capabilities. We further examined injuries in patients who report a significant drop in PCS 12 months post-crash despite being predicted to fully recover. At baseline, the CIREN population exhibited PCS scores similar to the overall population (mean = 51.1, SD = 10.3). Twelve months post-crash, occupants with predicted impairment (FCI < 100) report a substantial decrease in physical function, and those who were predicted to fully recover still report some, albeit less, impairment. In the multivariate mixed-effects regression model, FCI is a strongly significant (P-value <.0001) predictor of PCS, with each 1-point drop in FCI predicting a 0.27-point drop in PCS. Maximum AIS severities in the head, spine, and lower extremity body regions were also significantly associated with PCS (P-values <.05). Among occupants who were expected to fully recover but who report a significant drop in PCS at 12 months, spinal fractures without cord involvement account for 5 of the 10 most common AIS 2+ injuries. FCI was associated with 12-month outcomes but may not adequately describe the recovery from some head, spine, and lower extremity injuries. Some occupants who were expected to recover still report functional loss 12 months post-injury.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamada, Etsu; Kimura, Mitsuo; Tomozawa, Kenichi
1999-12-01
A simple analysis of atmospheric NO{sub 2}, SO{sub 2}, and O{sub 3} in mountains by passive samplers was investigated and applied to the spatial analysis of air pollutants at Mt. Hiei in Kyoto City, Passive samplers were exposed for 30 days. Yanagisawa-type samplers were used for NO{sub 2} determination. The absorbed NO{sub 2} was measured as nitrite ion spectro-photometrically by the Saltzman method. On the other hand, SO{sub 2} samplers comprising an absorbent filter containing sodium carbonate solution were made. The absorbed SO{sub 2} was oxidized to SO{sub 4}{sup 2{minus}} with an H{sub 2}O{sub 2} solution and determined by ionmore » chromatography. For O{sub 3} determination, Ogawa ozone samplers were used. The O{sub 3} reacted with nitrite ion to produce nitrate ion, which was measured by ion chromatography. The relative standard deviations for NO{sub 2}, SO{sub 2}, and O{sub 3} samplers were 1.4%, 3--10%, and 2--5%, respectively. Samplers were set up in 13 locations at Mt. Hiei. The NO{sub 2} concentration and its distribution along the slope of Mt. Hiei changed considerably both daily and seasonally. The seasonal variation of atmospheric NO{sub 2} showed a winter maximum and a summer minimum. The concentration of atmospheric SO{sub 2} at Mt. Hiei was lower than that of NO{sub 2} and scarcely changed. Atmospheric O{sub 3} increased gradually with an increase of the altitude, exhibiting a regular pattern with a maximum in spring and a minimum in winter.« less
Liao, Chunyang; Richards, Jaben; Taylor, Allison R; Gan, Jay
2017-12-01
Widespread use of insecticides for the control of urban pests such as ants, termites, and spiders has resulted in contamination and toxicity in urban aquatic ecosystems in different regions of the world. Passive samplers are a convenient and integrative tool for in situ monitoring of trace contaminants in surface water. However, the performance of a passive sampler depends closely on its affinity for the target analytes, making passive samplers highly specific to the types of contaminants being monitored. The goal of this study was to develop a passive sampler compatible with a wide range of insecticides, including the strongly hydrophobic pyrethroids and the weakly hydrophobic fipronil and organophosphates. Of six candidate polymeric thin films, polyurethane film (PU) was identified to be the best at enriching the test compounds. The inclusion of stable isotope labeled analogs as performance reference compounds (PRCs) further allowed the use of PU film for pyrethroids under non-equilibrium conditions. The PU sampler was tested in a large aquarium with circulatory water flow, and also deployed at multiple sites in surface streams in southern California. The concentrations of pesticides derived from the PU sampler ranged from 0.5 to 18.5 ng/L, which were generally lower than the total chemical concentration measured by grab samples, suggesting that suspended particles and dissolved organic matter in water rendered them less available. The influence of suspended particles and dissolved organic matter on bioavailability was more pronounced for pyrethroids than for fipronils. The results show that the developed PU film sampler, when coupled with PRCs, may be used for rapid and sensitive in-situ monitoring of a wide range of insecticides in surface water. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Page, Declan; Miotliński, Konrad; Gonzalez, Dennis; Barry, Karen; Dillon, Peter; Gallen, Christie
2014-03-01
Water recycling via aquifers has become a valuable tool to augment urban water supplies in many countries. This study reports the first use of passive samplers for monitoring of organic micropollutants in Managed Aquifer Recharge (MAR). Five different configurations of passive samplers were deployed in a stormwater treatment wetland, groundwater monitoring wells and a recovery tank to capture a range of polar and non-polar micropollutants present in the system. The passive samplers were analysed for a suite of pesticides, polycyclic aromatic hydrocarbons (PAHs) and other chemicals. As a result, 17 pesticides and pesticide degradation products, 5 PAHs and 8 other organic chemicals including flame retardants and fragrances were detected in urban stormwater recharging Aquifer Storage and Recovery (ASR) and an Aquifer Storage Transfer and Recovery (ASTR) system. Of the pesticides detected, diuron, metolachlor and chlorpyrifos were generally detected at the highest concentrations in one or more passive samplers, whereas chlorpyrifos, diuron, metolachlor, simazine, galaxolide and triallate were detected in multiple samplers. Fluorene was the PAH detected at the highest concentration and the flame retardant Tris(1-chloro-2-propyl)phosphate was the chemical detected in the greatest abundance at all sites. The passive samplers showed different efficiencies for capture of micropollutants with the Empore disc samplers giving the most reliable results. The results indicate generally low levels of organic micropollutants in the stormwater, as the contaminants detected were present at very low ng/L levels, generally two to four orders of magnitude below the drinking water guidelines (NHMRC, 2011). The efficiency of attenuation of these organic micropollutants during MAR was difficult to determine due to variations in the source water concentrations. Comparisons were made between different samplers, to give a field-based calibration where existing lab-based calibrations were unavailable.
Improved Large-Volume Sampler for the Collection of Bacterial Cells from Aerosol
White, L. A.; Hadley, D. J.; Davids, D. E.; Naylor, R.
1975-01-01
A modified large-volume sampler was demonstrated to be an efficient device for the collection of mono-disperse aerosols of rhodamine B and poly-disperse aerosols of bacterial cells. Absolute efficiency for collection of rhodamine B varied from 100% with 5-μm particles to about 70% with 0.5-μm particles. The sampler concentrated the particles from 950 liters of air into a flow of between 1 and 2 ml of collecting fluid per min. Spores of Bacillus subtilis var. niger were collected at an efficiency of about 82% compared to the collection in the standard AGI-30 sampler. In the most desirable collecting fluids tested, aerosolized cells of Serratia marcescens, Escherichia coli, and Aerobacter aerogenes were collected at comparative efficiencies of approximately 90, 80, and 90%, respectively. The modified sampler has practical application in the study of aerosol transmission of respiratory pathogens. Images PMID:803820
A source of PCB contamination in modified high-volume air samplers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Basu, I.; O'Dell, J.M.; Arnold, K.
2000-02-01
Modified Anderson High Volume (Hi-Vol) air samplers are widely used for the collection of semi-volatile organic compounds (such as PCBs) from air. The foam gasket near the main air flow path in these samplers can become contaminated with PCBs if the sampler or the gasket is stored at a location with high indoor air PCB levels. Once the gasket is contaminated, it releases PCBs back into the air stream during sampling, and as a result, incorrectly high air PCB concentrations are measured. This paper presents data demonstrating this contamination problem using measurements from two Integrated Atmospheric Deposition Network sites: onemore » at Sleeping Bear Dunes on Lake Michigan and the other at Point Petre on Lake Ontario. The authors recommend that these gaskets be replaced by Teflon tape and that the storage history of each sampler be carefully tracked.« less
Vroblesky, Don A.
2001-01-01
Diffusion samplers installed in observation wells were found to be capable of yielding representative water samples for chlorinated volatile organic compounds. The samplers consisted of polyethylene bags containing deionized water and relied on diffusion of chlorinated volatile organic compounds through the polyethylene membrane. The known ability of polyethylene to transmit other volatile compounds, such as benzene and toluene, indicates that the samplers can be used for a variety of volatile organic compounds. In wells at the study area, the volatile organic compound concentrations in water samples obtained using the samplers without prior purging were similar to concentrations in water samples obtained from the respective wells using traditional purging and sampling approaches. The low cost associated with this approach makes it a viable option for monitoring large observation-well networks for volatile organic compounds.
Vroblesky, Don A.
2001-01-01
Diffusion samplers installed in observation wells were found to be capable of yielding representative water samples for chlorinated volatile organic compounds. The samplers consisted of polyethylene bags containing deionized water and relied on diffusion of chlorinated volatile organic compounds through the polyethylene membrane. The known ability of polyethylene to transmit other volatile compounds, such as benzene and toluene, indicates that the samplers can be used for a variety of volatile organic compounds. In wells at the study area, the volatile organic compound concentrations in water samples obtained using the samplers without prior purging were similar to concentrations in water samples obtained from the respective wells using traditional purging and sampling approaches. The low cost associated with this approach makes it a viable option for monitoring large observation-well networks for volatile organic compounds.
NASA Astrophysics Data System (ADS)
Bilonick, Richard A.; Connell, Daniel P.; Talbott, Evelyn O.; Rager, Judith R.; Xue, Tao
2015-02-01
The objective of this study was to remove systematic bias among fine particulate matter (PM2.5) mass concentration measurements made by different types of samplers used in the Pittsburgh Aerosol Research and Inhalation Epidemiology Study (PARIES). PARIES is a retrospective epidemiology study that aims to provide a comprehensive analysis of the associations between air quality and human health effects in the Pittsburgh, Pennsylvania, region from 1999 to 2008. Calibration was needed in order to minimize the amount of systematic error in PM2.5 exposure estimation as a result of including data from 97 different PM2.5 samplers at 47 monitoring sites. Ordinary regression often has been used for calibrating air quality measurements from pairs of measurement devices; however, this is only appropriate when one of the two devices (the "independent" variable) is free from random error, which is rarely the case. A group of methods known as "errors-in-variables" (e.g., Deming regression, reduced major axis regression) has been developed to handle calibration between two devices when both are subject to random error, but these methods require information on the relative sizes of the random errors for each device, which typically cannot be obtained from the observed data. When data from more than two devices (or repeats of the same device) are available, the additional information is not used to inform the calibration. A more general approach that often has been overlooked is the use of a measurement error structural equation model (SEM) that allows the simultaneous comparison of three or more devices (or repeats). The theoretical underpinnings of all of these approaches to calibration are described, and the pros and cons of each are discussed. In particular, it is shown that both ordinary regression (when used for calibration) and Deming regression are particular examples of SEMs but with substantial deficiencies. To illustrate the use of SEMs, the 7865 daily average PM2.5 mass concentration measurements made by seven collocated samplers at an urban monitoring site in Pittsburgh, Pennsylvania, were used. These samplers, which included three federal reference method (FRM) samplers, three speciation samplers, and a tapered element oscillating microbalance (TEOM), operated at various times during the 10-year PARIES study period. Because TEOM measurements are known to depend on temperature, the constructed SEM provided calibration equations relating the TEOM to the FRM and speciation samplers as a function of ambient temperature. It was shown that TEOM imprecision and TEOM bias (relative to the FRM) both decreased as temperature increased. It also was shown that the temperature dependency for bias was non-linear and followed a sigmoidal (logistic) pattern. The speciation samplers exhibited only small bias relative to the FRM samplers, although the FRM samplers were shown to be substantially more precise than both the TEOM and the speciation samplers. Comparison of the SEM results to pairwise simple linear regression results showed that the regression results can differ substantially from the correctly-derived calibration equations, especially if the less-precise device is used as the independent variable in the regression.
NASA Astrophysics Data System (ADS)
Mailloux, B.; Hall, j; Fuller, M.; Scheibe, T.; DeFlaun, M.; Onstott, T.
2001-12-01
A novel approach to examining the mechanisms controlling the velocity and attachment of bacteria in porous media was developed for the South Oyster Bacterial Transport Field Site. Instead of performing bacterial transport experiments in the lab using repacked materials and artificial water, samples of sediment core, 7 cm. in length, were connected to multi-level samplers at the field site, the groundwater from select levels in the aquifer was pumped through the cores, and an aliquot of cells stained with a viable, fluorescent dye was injected with Br into the influent end of the cores. The same cells, Br and groundwater were simultaneously passed through repacked cores composed of sieved sand of varying grain size fractions (100 to 600 diameter) and a single grain size fraction coated with Fe and Al synthetic oxides. The grain size of the coated sand and the Fe and Al concentrations of the coated sand (500 to 1000 ppm) were representative of the average value of the aquifer. By using this approach, the parameters that are difficult to reproduce in the lab, e.g., the dissolved gas concentrations, pH, temperature, dissolved organic matter, the indigenous bacterial and protist populations, could be replicated. One of the results derived from 29 short core experiments indicate that the enhanced velocity of adhesion deficient DA001 that has been reported in laboratory experiments was greatly reduced in the field experiments for the Fe and Al coated sands and greatly enhanced for the fine grained sands.
Nakai, S; Wang, Z H; Dou, J; Nakamura, S; Ogawa, M; Nakai, E; Vanderstoep, J
1999-02-01
Coho, Atlantic, Spring, and Sockeye salmon and five commercial samples of hamburger patties were analyzed by processing gas chromatography (GC) data of volatile compounds using the principal component similarity (PCS) technique. PCS scattergrams of the samples inoculated with Escherichia coli and Staphylococcus aureus followed by incubation showed the pattern-shift lines moving away from the data point for uninoculated, unincubated reference samples in different directions with increasing incubation time. When the PCS scattergrams were drawn for samples incubated overnight, the samples inoculated with the two bacterial species and the uninoculated samples appeared as three separated groups. This GC/PCS approach has the potential to ensure quality of samples by discriminating good samples from potentially spoiled samples. The latter may require further microbial assays to identify the bacteria species potentially contaminating foods.
Multidecadal climate variability of global lands and oceans
McCabe, G.J.; Palecki, M.A.
2006-01-01
Principal components analysis (PCA) and singular value decomposition (SVD) are used to identify the primary modes of decadal and multidecadal variability in annual global Palmer Drought Severity Index (PDSI) values and sea-surface temperature (SSTs). The PDSI and SST data for 1925-2003 were detrended and smoothed (with a 10-year moving average) to isolate the decadal and multidecadal variability. The first two principal components (PCs) of the PDSI PCA explained almost 38% of the decadal and multidecadal variance in the detrended and smoothed global annual PDSI data. The first two PCs of detrended and smoothed global annual SSTs explained nearly 56% of the decadal variability in global SSTs. The PDSI PCs and the SST PCs are directly correlated in a pairwise fashion. The first PDSI and SST PCs reflect variability of the detrended and smoothed annual Pacific Decadal Oscillation (PDO), as well as detrended and smoothed annual Indian Ocean SSTs. The second set of PCs is strongly associated with the Atlantic Multidecadal Oscillation (AMO). The SVD analysis of the cross-covariance of the PDSI and SST data confirmed the close link between the PDSI and SST modes of decadal and multidecadal variation and provided a verification of the PCA results. These findings indicate that the major modes of multidecadal variations in SSTs and land-surface climate conditions are highly interrelated through a small number of spatially complex but slowly varying teleconnections. Therefore, these relations may be adaptable to providing improved baseline conditions for seasonal climate forecasting. Published in 2006 by John Wiley & Sons, Ltd.
pH value promotes growth of Staphylococcus epidermidis in platelet concentrates.
Störmer, Melanie; Kleesiek, Knut; Dreier, Jens
2008-05-01
The platelet (PLT) storage lesion is characterized metabolically by a pH value associated with lactic acid generation. PLT storage conditions support the growth of Staphylococcus epidermidis, the most common organism implicated in bacterial contamination of PLT concentrates (PCs). Here, different factors that influence bacterial growth in PCs are discussed and the relation between pH values of PCs and citrate plasma (CP) is studied, with emphasis on bacterial proliferation. The PLT lesion with regard to pH decrease and lactic acid production was monitored during storage and correlated to bacterial proliferation properties. A total of 115 coagulase-negative staphylococci, especially S. epidermidis isolates, were characterized for their proliferation in different blood components (CP, buffy coat-derived, and apheresis PCs). Furthermore, the influence of donor-specific, product-specific, species-specific, and strain-specific factors on bacterial proliferation was investigated. PCs showed a lower pH value in comparison to plasma during storage. Bacterial proliferation in PCs and the failure to grow in CP were determined with all organisms tested. No correlation to donor-specific, species-specific, or strain-specific factors was observed. Lowering the pH of CP resulted in bacterial proliferation, whereas a pH increase in the PC unit inhibited the proliferation of S. epidermidis. With emphasis on bacterial proliferation, the significant difference between PC and CP is the presence of metabolizing PLTs. The pH values of stored PLTs, but not those of stored plasma, support the growth of S. epidermidis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meneses, Luis, E-mail: lmeneseq@gmail.com; Fava, Mario; Diaz, Pia
We present our experience with embolization of incompetent pelvic veins (IPV) in women with recurrence of varicose veins (VV) in lower limbs, as well as symptoms of pelvic congestion syndrome (PCS), after first surgery. In addition, we evaluated the effects of embolization in decreasing the symptoms of VV before surgery as well as its effects on PCS symptoms. We included 10 women who had consulted a vascular surgeon because of recurrent VV in lower limbs after surgery. All of these patients were included in the study because they also had symptoms of PCS, probably due to IPV. In patients whomore » had confirmed IPV, we performed embolization before a second surgery. VV and PCS were assessed before and at 3 months after embolization (before the second surgery) using a venous clinical severity score (VCSS) and a visual analog pain scale (VAS), respectively. Patients were controlled between 3 and 6 months after embolization. Paired Student t test analysis was used for comparing data before and after embolization. Fifteen vein segments in 10 women were suitable for embolization. There was a significant (p < 0.001) decrease of VCSS after embolization, and recurrence of VV was not detected within a period of 6 months. There was also significant (p < 0.01) relief of chronic pelvic pain related to PCS evaluated using VAS at 3 months after embolization. Embolization decreases the risk of VV recurrence after surgery and also improves PCS symptoms in women with VV in lower limbs and IPV.« less
Stanzani, Fabiana; Paisani, Denise de Moraes; de Oliveira, Anderson; de Souza, Rodrigo Caetano; Perfeito, João Aléssio Juliano; Faresin, Sonia Maria
2014-01-01
OBJECTIVE: To determine morbidity and mortality rates by risk category in accordance with the American College of Chest Physicians guidelines, to determine what role pulmonary function tests play in this categorization process, and to identify risk factors for perioperative complications (PCs). METHODS: This was a historical cohort study based on preoperative and postoperative data collected for cases of lung cancer diagnosed or suspected between 2001 and 2010. RESULTS: Of the 239 patients evaluated, only 13 (5.4%) were classified as being at high risk of PCs. Predicted postoperative FEV1 (FEV1ppo) was sufficient to define the risk level in 156 patients (65.3%); however, cardiopulmonary exercise testing (CPET) was necessary for identifying those at high risk. Lung resection was performed in 145 patients. Overall morbidity and mortality rates were similar to those reported in other studies. However, morbidity and mortality rates for patients at an acceptable risk of PCs were 31.6% and 4.3%, respectively, whereas those for patients at high risk were 83.3% and 33.3%. Advanced age, COPD, lobe resection, and lower FEV1ppo were correlated with PCs. CONCLUSIONS: Although spirometry was sufficient for risk assessment in the majority of the population studied, CPET played a key role in the identification of high-risk patients, among whom the mortality rate was seven times higher than was that observed for those at an acceptable risk of PCs. The risk factors related to PCs coincided with those reported in previous studies. PMID:24626266
Optimization of Integrative Passive Sampling Approaches for Use in the Epibenthic Environment
2016-12-23
Passive sampler, POCIS, Integrative, Sediment , Benthic 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a...Unexploded ordnance, Passive sampler, POCIS, Integrative, Sediment , Benthic v Acknowledgements Dr. Shane Morrison and Ms. Ingrid...flow and turbulence near the sampler. In complex environments at the sediment – water interface, this may limit the utility of passive sampling
40 CFR 53.34 - Test procedure for methods for PM10 and Class I methods for PM2.5.
Code of Federal Regulations, 2010 CFR
2010-07-01
... simultaneous PM10 or PM2.5 measurements as necessary (see table C-4 of this subpart), each set consisting of...) in appendix A to this subpart). (f) Sequential samplers. For sequential samplers, the sampler shall be configured for the maximum number of sequential samples and shall be set for automatic collection...
Evaluating the Relationship between Equilibrium Passive ...
This review evaluates passive sampler uptake of hydrophobic organic contaminants (HOCs) as it relates to organism bioaccumulation in the water column and interstitial water. Fifty-five studies were found where both passive samplers and organism bioaccumulation were used to measured water quality. Of these investigations, 19 provided direct comparisons relating passive sampler concentrations and organism bioaccumulation. Passive sampling polymers included in the review were: low density polyethylene (LDPE); polyoxymethylene (POM); and polydimethylsiloxane (PDMS), and organisms ranged from polychaetes and oligochaetes to bivalves, aquatic insects, and gastropods. Log-linear regressions correlating bioaccumulation (CL) and passive sampler concentration (CPS) were used to assess the strength of observed relationships. In general, the passive sampler concentrations resulted in statistically-significant, logarithmic, predictive relationships, most of which were within one to two orders of magnitude of measured bioaccumulation. Overall, bioaccumulation values were greater than passive sampler concentrations. A mean ratio of CL to CPS was 10.8 ± 18.4 (n = 609) for available data. Given that all studies presented resulted in a strong CL versus CPS relationship suggests that using passive sampling as a surrogate for organism bioaccumulation is viable when biomonitoring organisms are not available. Passive sampling based measurements can provide useful information for ma
NASA Astrophysics Data System (ADS)
Okeme, Joseph O.; Saini, Amandeep; Yang, Congqiao; Zhu, Jiping; Smedes, Foppe; Klánová, Jana; Diamond, Miriam L.
2016-10-01
Polydimethylsiloxane (PDMS) has seen wide use as the stationary phase of gas chromatographic columns, a passive sampler in water, and recently as a personal exposure sampler, while styrene divinyl-benzene copolymer (XAD) has been used extensively as a passive air sampler outdoors and indoors. We have introduced PDMS and XAD-Pocket as new indoor passive air samplers (PASs). The XAD-Pocket was designed to maximize the surface area-to-volume ratio of XAD and to minimize obstruction of air flow by the sampler housing. Methods were developed to expedite the use of these PASs for measuring phthalates, novel brominated flame-retardants (NFRs) and polybrominated diphenyl ethers (PBDEs) indoors. Sampling rates, Rs, (m3 day-1), were measured during a 7-week calibration study. Variability within and between analyte groups was not statistically significant. As a result, generic values of 0.8 ± 0.4 and 0.5 ± 0.3 m3 day-1 dm-2 are recommended for PDMS and XAD-Pocket for a 50-day deployment time, respectively. PDMS has a higher uptake rate and is easier to use than XAD-Pocket.
Chemical and toxicologic assessment of organic contaminants in surface water using passive samplers
Alvarez, D.A.; Cranor, W.L.; Perkins, S.D.; Clark, R.C.; Smith, S.B.
2008-01-01
Passive sampling methodologies were used to conduct a chemical and toxicologic assessment of organic contaminants in the surface waters of three geographically distinct agricultural watersheds. A selection of current-use agrochemicals and persistent organic pollutants, including polycyclic aromatic hydrocarbons, polychlorinated biphenyls, and organochlorine pesticides, were targeted using the polar organic chemical integrative sampler (POCIS) and the semipermeable membrane device passive samplers. In addition to the chemical analysis, the Microtox assay for acute toxicity and the yeast estrogen screen (YES) were conducted as potential assessment tools in combination with the passive samplers. During the spring of 2004, the passive samplers were deployed for 29 to 65 d at Leary Weber Ditch, IN; Morgan Creek, MD; and DR2 Drain, WA. Chemical analysis of the sampler extracts identified the agrochemicals predominantly used in those areas, including atrazine, simazine, acetochlor, and metolachlor. Other chemicals identified included deethylatrazine and deisopropylatrazine, trifluralin, fluoranthene, pyrene, cis- and trans-nonachlor, and pentachloroanisole. Screening using Microtox resulted in no acutely toxic samples. POCIS samples screened by the YES assay failed to elicit a positive estrogenic response. Copyright ?? 2008 by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America. All rights reserved.
Practical considerations for measuring hydrogen concentrations in groundwater
Chapelle, F.H.; Vroblesky, D.A.; Woodward, J.C.; Lovley, D.R.
1997-01-01
Several practical considerations for measuring concentrations of dissolved molecular hydrogen (H2) in groundwater including 1 sampling methods 2 pumping methods and (3) effects of well casing materials were evaluated. Three different sampling methodologies (a downhole sampler, a gas- stripping method, and a diffusion sampler) were compared. The downhole sampler and gas-stripping methods gave similar results when applied to the same wells, the other hand, appeared to The diffusion sampler, on overestimate H2 concentrations relative to the downhole sampler. Of these methods, the gas-stripping method is better suited to field conditions because it is faster (~ 30 min for a single analysis as opposed to 2 h for the downhole sampler or 8 h for the diffusion sampler), the analysis is easier (less sample manipulation is required), and the data computations are more straightforward (H2 concentrations need not be corrected for water sample volume). Measurement of H2 using the gas-stripping method can be affected by different pumping equipment. Peristaltic, piston, and bladder pumps all gave similar results when applied to water produced from the same well. It was observed, however, that peristaltic-pumped water (which draws water under a negative pressure) enhanced the gas-stripping process and equilibrated slightly faster than either piston or bladder pumps (which push water under a positive pressure). A direct current(dc) electrically driven submersible pump was observed to produce H2 and was not suitable for measuring H2 in groundwater. Measurements from two field sites indicate that iron or steel well casings, produce H2, which masks H2 concentrations in groundwater. PVC-cased wells or wells cased with other materials that do not produce H2 are necessary for measuring H2 concentrations in groundwater.Several practical considerations for measuring concentrations of dissolved molecular hydrogen in groundwater including sampling methods, pumping methods, and effects of well casing materials were evaluated. The downhole sampler and gas-stripping methods gave similar results when applied to the same wells. The diffusional sampler appears to overestimate H2 concentrations relative to the downhole sampler. Gas-stripping method is better for a single analysis and the data computations are more straightforward. Measurement of H2 using the gas-stripping method can be affected by different pumping equipment.
Tominaga, M Y; Silva, C R; Melo, J P; Niwa, N A; Plascak, D; Souza, C A M; Sato, M I Z
2016-11-15
The persistent organic pollutants (POPs), such as organochlorine pesticides and PCBs, are ordinarily monitored in the aquatic environment or in soil in the environmental quality monitoring programs in São Paulo, Brazil. One of the core matrices proposed in the POPs Global Monitoring Plan (GMP) from the Stockholm Convention list is the ambient air, which is not a usual matrix for POPs monitoring in the country. In this study POP levels were evaluated in the air samples from an urban site in São Paulo City over five years, starting in 2010 as a capacity building project for Latin America and the Caribbean region for POP monitoring in ambient air using passive samplers. Furthermore, after the end of the Project in 2012, the monitoring continued in the same sampling site as means to improving the analytical capacity building and contribute to the GMP data. The POPs monitored were 17 congeners of 2,3,7,8 chloro-substituted PCDDs and PCDFs, dioxin-like PCBs, indicator PCBs, organochlorine pesticides and toxaphene. The results show a slight decrease in PCDD/F, dl-PCBs and indicator PCBs levels along the five years. The organochlorine pesticide endosulfan was present at its highest concentration at the beginning of the monitoring period, but it was below detection level in the last year of the monitoring. Some other organochlorine pesticides were detected close to or below quantitation limits. The compounds identified were dieldrin, chlordane, α-HCH, γ-HCH, heptachlor, heptachlor epoxide, hexachlorobenzene and DDTs. Toxaphene congeners were not detected. These results have confirmed the efficacy of passive sampling for POP monitoring and the capacity building for POP analysis and monitoring was established. However more needs to be done, including expansion of sampling sites, new POPs and studies on sampling rates to be considered in calculating the concentration of POPs in ambient air using a passive sampler. Copyright © 2016 Elsevier B.V. All rights reserved.
Tang, Tianyu; Xiao, Jianqiang; Suh, Colleen Y; Burroughs, Amelia; Cerminara, Nadia L; Jia, Linjia; Marshall, Sarah P; Wise, Andrew K; Apps, Richard; Sugihara, Izumi; Lang, Eric J
2017-08-01
Cerebellar Purkinje cells (PCs) generate two types of action potentials, simple and complex spikes. Although they are generated by distinct mechanisms, interactions between the two spike types exist. Zebrin staining produces alternating positive and negative stripes of PCs across most of the cerebellar cortex. Thus, here we compared simple spike-complex spike interactions both within and across zebrin populations. Simple spike activity undergoes a complex modulation preceding and following a complex spike. The amplitudes of the pre- and post-complex spike modulation phases were correlated across PCs. On average, the modulation was larger for PCs in zebrin positive regions. Correlations between aspects of the complex spike waveform and simple spike activity were found, some of which varied between zebrin positive and negative PCs. The implications of the results are discussed with regard to hypotheses that complex spikes are triggered by rises in simple spike activity for either motor learning or homeostatic functions. Purkinje cells (PCs) generate two types of action potentials, called simple and complex spikes (SSs and CSs). We first investigated the CS-associated modulation of SS activity and its relationship to the zebrin status of the PC. The modulation pattern consisted of a pre-CS rise in SS activity, and then, following the CS, a pause, a rebound, and finally a late inhibition of SS activity for both zebrin positive (Z+) and negative (Z-) cells, though the amplitudes of the phases were larger in Z+ cells. Moreover, the amplitudes of the pre-CS rise with the late inhibitory phase of the modulation were correlated across PCs. In contrast, correlations between modulation phases across CSs of individual PCs were generally weak. Next, the relationship between CS spikelets and SS activity was investigated. The number of spikelets/CS correlated with the average SS firing rate only for Z+ cells. In contrast, correlations across CSs between spikelet numbers and the amplitudes of the SS modulation phases were generally weak. Division of spikelets into likely axonally propagated and non-propagated groups (based on their interspikelet interval) showed that the correlation of spikelet number with SS firing rate primarily reflected a relationship with non-propagated spikelets. In sum, the results show both zebrin-related and non-zebrin-related physiological heterogeneity in SS-CS interactions among PCs, which suggests that the cerebellar cortex is more functionally diverse than is assumed by standard theories of cerebellar function. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.
Clinical predictors of vestibulo-ocular dysfunction in pediatric sports-related concussion.
Ellis, Michael J; Cordingley, Dean M; Vis, Sara; Reimer, Karen M; Leiter, Jeff; Russell, Kelly
2017-01-01
OBJECTIVE There were 2 objectives of this study. The first objective was to identify clinical variables associated with vestibulo-ocular dysfunction (VOD) detected at initial consultation among pediatric patients with acute sports-related concussion (SRC) and postconcussion syndrome (PCS). The second objective was to reexamine the prevalence of VOD in this clinical cohort and evaluate the effect of VOD on length of recovery and the development of PCS. METHODS A retrospective review was conducted for all patients with acute SRC and PCS who were evaluated at a pediatric multidisciplinary concussion program from September 2013 to May 2015. Acute SRS was defined as presenting < 30 days postinjury, and PCS was defined according to the International Classification of Diseases, 10th Revision criteria and included being symptomatic 30 days or longer postinjury. The initial assessment included clinical history and physical examination performed by 1 neurosurgeon. Patients were assessed for VOD, defined as the presence of more than 1 subjective vestibular and oculomotor complaint (dizziness, diplopia, blurred vision, etc.) and more than 1 objective physical examination finding (abnormal near point of convergence, smooth pursuits, saccades, or vestibulo-ocular reflex testing). Poisson regression analysis was used to identify factors that increased the risk of VOD at initial presentation and the development of PCS. RESULTS Three hundred ninety-nine children, including 306 patients with acute SRC and 93 with PCS, were included. Of these patients, 30.1% of those with acute SRC (65.0% male, mean age 13.9 years) and 43.0% of those with PCS (41.9% male, mean age 15.4 years) met the criteria for VOD at initial consultation. Independent predictors of VOD at initial consultation included female sex, preinjury history of depression, posttraumatic amnesia, and presence of dizziness, blurred vision, or difficulty focusing at the time of injury. Independent predictors of PCS among patients with acute SRC included the presence of VOD at initial consultation, preinjury history of depression, and posttraumatic amnesia at the time of injury. CONCLUSIONS This study identified important potential risk factors for the development of VOD following pediatric SRC. These results provide confirmatory evidence that VOD at initial consultation is associated with prolonged recovery and is an independent predictor for the development of PCS. Future studies examining clinical prediction rules in pediatric concussion should include VOD. Additional research is needed to elucidate the natural history of VOD following SRC and establish evidence-based indications for targeted vestibular rehabilitation.
Brockmeyer, Berit; Kraus, Uta R; Theobald, Norbert
2015-12-01
Silicone passive samplers have gained an increasing attention as single-phased, practical and robust samplers for monitoring of organic contaminants in the aquatic environment in recent years. However, analytical challenges arise in routine application during the extraction of analytes as silicone oligomers are co-extracted and interfere severely during chemical analyses (e.g. gas chromatographic techniques). In this study, we present a fast, practical pre-cleaning method for silicone passive samplers applying accelerated solvent extraction (ASE) for the removal of silicone oligomers prior to the water deployment (hexane/dichloromethane, 100 °C, 70 min). ASE was also shown to be a very fast (10 min) and efficient extraction method for non-polar contaminants (non-exposed PRC recoveries 66-101 %) sampled by the silicone membrane. For both applications, temperature, extraction time and the solvent used for ASE have been optimized. Purification of the ASE extract was carried out by silica gel and high-pressure liquid size exclusion chromatography (HPLC-SEC). The silicone oligomer content was checked by total reflection X-ray fluorescence spectroscopy (TXRF) in order to confirm the absence of the silicone oligomers prior to analysis of passive sampler extracts. The established method was applied on real silicone samplers from the North- and Baltic Sea and showed no matrix effects during analysis of organic pollutants. Internal laboratory standard recoveries were in the same range for laboratory, transport and exposed samplers (85-126 %).
Heavy metals in atmospheric surrogate dry deposition
Morselli; Cecchini; Grandi; Iannuccilli; Barilli; Olivieri
1999-02-01
This paper describes a methodological approach for the assessment of the amount of surrogate dry deposition of several toxic heavy metals (Cd, Cr, Cu, Ni, Pb, V, Zn) associated with atmospheric particulate matter at ground level. The objectives of the study were twofold: i) the evaluation of several techniques for the digestion of dry deposition samples for trace metal analysis; ii) the comparison of the results from two samplers with different collecting surfaces. A dry solid surface sampler (DRY sampler, Andersen--USA) and a water layer surface sampler (DAS sampler--MTX Italy) were employed. The samples were collected over a one-year period in an urban site of Bologna (northern Italy). A description is given of the complete procedure, from sampling to data elaboration, including sample storage, digestion and analytical methods. According to the results obtained with three different digestion techniques (Teflon bomb, microwave digester and Teflon flask with vapour cooling system), the highest recovery rate was achieved by the Teflon bomb procedure employing an NBS 1648 Standard Reference Material; 90-95% of the elements considered were recovered by dissolution in a pressurized Teflon bomb with an HNO3-HF mixture. Given these results, the technique was adopted for dry deposition sample digestion. On the basis of the amount of heavy metals measured as monthly deposition fluxes (microg/m2), the collecting efficiency of the DAS sampler for a number of elements was found to be as much as two to three times greater than that of the DRY sampler.
Experimentally validated mathematical model of analyte uptake by permeation passive samplers.
Salim, F; Ioannidis, M; Górecki, T
2017-11-15
A mathematical model describing the sampling process in a permeation-based passive sampler was developed and evaluated numerically. The model was applied to the Waterloo Membrane Sampler (WMS), which employs a polydimethylsiloxane (PDMS) membrane as a permeation barrier, and an adsorbent as a receiving phase. Samplers of this kind are used for sampling volatile organic compounds (VOC) from air and soil gas. The model predicts the spatio-temporal variation of sorbed and free analyte concentrations within the sampler components (membrane, sorbent bed and dead volume), from which the uptake rate throughout the sampling process can be determined. A gradual decline in the uptake rate during the sampling process is predicted, which is more pronounced when sampling higher concentrations. Decline of the uptake rate can be attributed to diminishing analyte concentration gradient within the membrane, which results from resistance to mass transfer and the development of analyte concentration gradients within the sorbent bed. The effects of changing the sampler component dimensions on the rate of this decline in the uptake rate can be predicted from the model. Performance of the model was evaluated experimentally for sampling of toluene vapors under controlled conditions. The model predictions proved close to the experimental values. The model provides a valuable tool to predict changes in the uptake rate during sampling, to assign suitable exposure times at different analyte concentration levels, and to optimize the dimensions of the sampler in a manner that minimizes these changes during the sampling period.
ISOLOK VALVE ACCEPTANCE TESTING FOR DWPF SME SAMPLING PROCESS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edwards, T.; Hera, K.; Coleman, C.
2011-12-05
Evaluation of the Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. Of the opportunities, a focus area related to optimizing the equipment and efficiency of the sample turnaround time for DWPF Analytical Laboratory was identified. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) evaluated the possibility of using an Isolok{reg_sign} sampling valve as an alternative to the Hydragard{reg_sign} valve for taking process samples. Previous viability testing was conducted with favorable results using the Isolok sampler and reported in SRNL-STI-2010-00749 (1).more » This task has the potential to improve operability, reduce maintenance time and decrease CPC cycle time. This report summarizes the results from acceptance testing which was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 (2) and which was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNL-RP-2011-00145 (3). The Isolok to be tested is the same model which was tested, qualified, and installed in the Sludge Receipt Adjustment Tank (SRAT) sample system. RW-0333P QA requirements apply to this task. This task was to qualify the Isolok sampler for use in the DWPF Slurry Mix Evaporator (SME) sampling process. The Hydragard, which is the current baseline sampling method, was used for comparison to the Isolok sampling data. The Isolok sampler is an air powered grab sampler used to 'pull' a sample volume from a process line. The operation of the sampler is shown in Figure 1. The image on the left shows the Isolok's spool extended into the process line and the image on the right shows the sampler retracted and then dispensing the liquid into the sampling container. To determine tank homogeneity, a Coliwasa sampler was used to grab samples at a high and low location within the mixing tank. Data from the two locations were compared to determine if the contents of the tank were well mixed. The Coliwasa sampler is a tube with a stopper at the bottom and is designed to obtain grab samples from specific locations within the drum contents. A position paper (4) was issued to address the prototypic flow loop issues and simulant selections. A statistically designed plan (5) was issued to address the total number of samples each sampler needed to pull, to provide the random order in which samples were pulled and to group samples for elemental analysis. The TTR required that the Isolok sampler perform as well as the Hydragard sampler during these tests to ensure the acceptability of the Isolok sampler for use in the DWPF sampling cells. Procedure No.L9.4-5015 was used to document the sample parameters and process steps. Completed procedures are located in R&D Engineering job folder 23269.« less
The assessment of facial variation in 4747 British school children.
Toma, Arshed M; Zhurov, Alexei I; Playle, Rebecca; Marshall, David; Rosin, Paul L; Richmond, Stephen
2012-12-01
The aim of this study is to identify key components contributing to facial variation in a large population-based sample of 15.5-year-old children (2514 females and 2233 males). The subjects were recruited from the Avon Longitudinal Study of Parents and Children. Three-dimensional facial images were obtained for each subject using two high-resolution Konica Minolta laser scanners. Twenty-one reproducible facial landmarks were identified and their coordinates were recorded. The facial images were registered using Procrustes analysis. Principal component analysis was then employed to identify independent groups of correlated coordinates. For the total data set, 14 principal components (PCs) were identified which explained 82 per cent of the total variance, with the first three components accounting for 46 per cent of the variance. Similar results were obtained for males and females separately with only subtle gender differences in some PCs. Facial features may be treated as a multidimensional statistical continuum with respect to the PCs. The first three PCs characterize the face in terms of height, width, and prominence of the nose. The derived PCs may be useful to identify and classify faces according to a scale of normality.
Asymmetric SOL Current in Vertically Displaced Plasma
NASA Astrophysics Data System (ADS)
Cabrera, J. D.; Navratil, G. A.; Hanson, J. M.
2017-10-01
Experiments at the DIII-D tokamak demonstrate a non-monotonic relationship between measured scrape-off layer (SOL) currents and vertical displacement event (VDE) rates with SOL currents becoming largely n=1 dominant as plasma is displaced by the plasma control system (PCS) at faster rates. The DIII-D PCS is used to displace the magnetic axis 10x slower than the intrinsic growth time of similar instabilities in lower single-null plasmas. Low order (n <=2) mode decomposition is done on toroidally spaced current monitors to attain measures of asymmetry in SOL current. Normalized to peak n=0 response, a 2-4x increase is seen in peak n=1 response in plasmas displaced by the PCS versus previous VDE instabilities observed when vertical control is disabled. Previous inquiry shows VDE asymmetry characterized by SOL current fraction and geometric parameters of tokamak plasmas. We note that, of plasmas displaced by the PCS, short displacement time scales near the limit of the PCS temporal control appear to result in larger n=1/n=2 asymmetries. Work supported under USDOE Cooperative Agreement DE-FC02-04ER54698 and DE-FG02-04ER54761.
Soncin, M.; Polo, L.; Reddi, E.; Jori, G.; Kenney, M. E.; Cheng, G.; Rodgers, M. A.
1995-01-01
Four Ge(IV)-octabutoxy-phthalocyanines (GePcs) bearing two alkyl-type axial ligands were assayed for their pharmacokinetic properties and phototherapeutic efficiency in Balb/c mice bearing an intramuscularly transplanted MS-2 fibrosarcoma. The GePcs were i.v. injected at a dose of 0.35 mumol kg-1 body weight after incorporation into either Cremophor emulsions or small unilamellar liposomes of dipalmitoyl-phosphatidylcholine (DPPC). Both the nature of the delivery system and the chemical structure of the phthalocyanine were found to affect the behaviour of the GePcs in vivo. Thus, Cremophor-administered GePcs invariably yielded a more prolonged serum retention and a larger association with low-density lipoproteins (LDLs) as compared with the corresponding liposome-delivered phthalocyanines. This led to a greater efficiency and selectivity of tumour targeting. These effects were more pronounced for those GePcs having relatively long alkyl chains (hexyl to decyl) in the axial ligands. Maximal tumour accumulation (0.67 nmol per g of tissue) was found for Ge-Pc(hexyl)2 at 24 h after injection. Consistently, the Ge-Pc(hexyl)2, administered via Cremophor, showed the highest phototherapeutic activity towards MS-2 fibrosarcoma. PMID:7710936
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mitrofanov, K. N., E-mail: mitrkn@inbox.ru; Krauz, V. I., E-mail: krauz-vi@nrcki.ru, E-mail: vkrauz@yandex.ru; Grabovski, E. V.
The main stages of the plasma current sheath (PCS) dynamics on two plasma focus (PF) facilities with different geometries of the electrode system, PF-3 (Filippov type) and PF-1000 (Mather type), were studied by analyzing the results of the current and voltage measurements. Some dynamic characteristics, such as the PCS velocity in the acceleration phase in the Mather-type facility (PF-1000), the moment at which the PCS reaches the anode end, and the plasma velocity in the radial stage of plasma compression in the PF-3 Filippov-type facility, were determined from the time dependence of the inductance of the discharge circuit with amore » dynamic plasma load. The energy characteristics of the discharge circuit of the compressing PCS were studied for different working gases (deuterium, argon, and neon) at initial pressures of 1.5–3 Torr in discharges with energies of 0.3–0.6 MJ. In experiments with deuterium, correlation between the neutron yield and the electromagnetic energy deposited directly in the compressed PCS was investigated.« less
Attitude-referenced radiometer study. Part 2: Primary calibration system
NASA Technical Reports Server (NTRS)
Williamson, W. R.; Otte, A. A.
1971-01-01
A primary calibration system, PCS, for infrared radiometers has been developed, built, and tested. The system allows radiometers to be calibrated with less than 1 percent error for use in earth coverage horizon measurements, earth resources surveys, and synoptic meteorological measurement. The final design, fabrication and test of the PCS are reported. A detailed description of the PCS construction is presented, along with the results of a complete series of functional tests. Test to verify the source thermal characteristics, collimator reflectance, and output beam characteristics are described and their results presented.
NASA Astrophysics Data System (ADS)
Das, R.; Krauthamer, S.; Klein, J.
It is shown that the use of isolation transformers to eliminate dc injection into the utility in utility-interactive photovoltaic (PV) systems can reduce the overall efficiency of the system. In order to improve PV efficiency, a transformerless power conditioning subsystem (PCS) is proposed for a grounded PV array having two and three connections to a utility. An additional transformerless PCS configuration is proposed for an ungrounded PV array. A detailed schematic drawing of the interconnections between the elements of a transformerless PCS is provided.
2002-08-01
duty program (XPROG = 1, 4, or 5). Female 6 PCS moves 7 PCS moves 8 PCS moves Total Enlisted Personnel Commissioned Officers Table 172.3 Title 10 ... 10 months to 12 months 7 months to less than 10 months 5 months to...data were used to resolve conflicts between answers, to fill in missing survey data, and to determine if an AGR/TAR/AR was Title 10 or Title 32. Data
Sampler collection gadget for epilithic diatoms.
Salomoni, S E; Torgan, L C; Rocha, O
2007-11-01
This work present a new gadget for sampling epilithic diatoms from both lentic and lotic enviroments. The sampler consists of a polystyrene cylinder, left to float on the surface of the water, to which stone substrates are attached. This epilithic diatom sampler (EDS) can be used to detect spatial and temporal richness and density variation in the study of the diatom community, as well as in water quality monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... II Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel... Results: 95% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km... Class II Equivalent Samplers F Table F-1 to Subpart F of Part 53 Protection of Environment ENVIRONMENTAL...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel Evaluation...% ≤ Rc ≤ 105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km/hr and 24... Class II Equivalent Samplers F Table F-1 to Subpart F of Part 53 Protection of Environment ENVIRONMENTAL...
Code of Federal Regulations, 2014 CFR
2014-07-01
... II Equivalent Samplers Performance test Specifications Acceptance criteria § 53.62 Full Wind Tunnel... Results: 95% ≤Rc ≤105%. § 53.63 Wind Tunnel Inlet Aspiration Test Liquid VOAG produced aerosol at 2 km/hr... Class II Equivalent Samplers F Table F-1 to Subpart F of Part 53 Protection of Environment ENVIRONMENTAL...
Tarte, Stephen R.; Schmidt, A.R.; Sullivan, Daniel J.
1992-01-01
A floating sample-collection platform is described for stream sites where the vertical or horizontal distance between the stream-sampling point and a safe location for the sampler exceed the suction head of the sampler. The platform allows continuous water sampling over the entire storm-runoff hydrogrpah. The platform was developed for a site in southern Illinois.
Miller, Jr., William H.
1976-01-01
A remotely operable sampler is provided for obtaining variable percentage samples of nuclear fuel particles and the like for analyses. The sampler has a rotating cup for a sample collection chamber designed so that the effective size of the sample inlet opening to the cup varies with rotational speed. Samples of a desired size are withdrawn from a flowing stream of particles without a deterrent to the flow of remaining particles.
NASA Astrophysics Data System (ADS)
Martin, Nicholas A.; Ferracci, Valerio; Cassidy, Nathan; Hook, Josh; Battersby, Ross M.; Tang, Yuk S.; Stevens, Amy C. M.; Jones, Matthew R.; Braban, Christine F.; Gates, Linda; Hangartner, Markus; Stoll, Jean-Marc; Sacco, Paolo; Pagani, Diego; Hoffnagle, John A.
2017-04-01
Intensive animal farming, the increased use of fertilizers, and certain industrial processes are believed to be responsible for the observed increases in the amount fraction of ammonia (NH3) found in Europe. NH3 contributes to eutrophication and acidification of land and freshwater, potentially leading to a loss of biodiversity and undesirable changes to the ecosystem. It also contributes to the formation of secondary particulate matter (PM) formation, which is associated with poor air quality and adverse health outcomes. Measurements of ambient ammonia are principally carried out with low-cost diffusive samplers or by active sampling with denuders, with each method delivering time-integrated values over the monitoring period. However, such techniques have not yet been extensively validated. The goal of this work was to provide improvements in the metrological traceability through the determination of NH3 diffusive sampling rates. Five different designs of commercial diffusive samplers (FSM Radiello radial sampler, Gradko diffusion tube, Gradko DIFRAM-400, Passam ammonia sampler, and CEH ALPHA sampler) were employed, together with a pumped denuder sampler (CEH DELTA denuder) for comparison. All devices were simultaneously exposed for either 28 days or 14 days (dependent on sampler type) in a controlled atmosphere test facility (CATFAC) containing traceable amount fractions of humidified ammonia using new stable ammonia Primary Standard Gas Mixtures developed by gravimetry at NPL, under a wide range of conditions that are relevant to ambient monitoring. Online continuous monitoring of the ammonia test atmospheres was carried out by extractive sampling, employing a calibrated cavity ring-down spectrometer, which had been modified to account for cross interference by water vapour. Each manufacturer extracted the captured ammonia on the exposed samplers in the form of ammonium (NH4+) using their own accredited traceable wet chemical techniques, and then reported data based on their historical diffusive sampling rates. There was considerable variation in the results, which demonstrated the need for such validation work to be carried out. We report new measurements of the NH3 sampling rates determined in the CATFAC, which can be applied to improve the reliability of measurements in the field.
Luoma, James A.; Severson, Todd J.
2016-01-01
The efficacy of whole water column and subsurface applications of the biopesticide Zequanox®, a commercially prepared spray-dried powder formulation of Pseudomonas fluorescens (strain CL145A), were evaluated for controlling zebra mussels (Dreissena polymorpha) within 27-m2 enclosures in Lake Minnetonka (Deephaven, Minnesota). Five treatments consisting of (1) two whole water column Zequanox applications, (2) two subsurface Zequanox applications, and (3) an untreated control were completed on each of three independent treatment days during September 2014. The two types of samplers used in the study were (1) type 1 samplers, which were custom built multi-plate samplers (wood, perforated aluminum, and tile substrates) that were placed into Robinson’s Bay in June of 2013 to allow for natural colonization by zebra mussels, and (2) type 2 samplers, which consisted of zebra mussels adhering to perforated aluminum trays that were placed into mesh containment bags. One day prior to treatment, three individual samplers of each type were distributed to test enclosures and exposed to a randomly assigned treatment. Sampling to determine the zebra mussel biomass adhering to type 1 samplers and the survival assessments for zebra mussels contained in type 2 samplers were completed ~40 days after exposure. The zebra mussel biomass adhering to type 1 samplers and the survival of zebra mussels contained in type 2 samplers were significantly less in groups treated with the highest Zequanox concentrations and in groups that received whole water column applications than comparable groups treated with lower Zequanox concentrations and subsurface applications. However, standardization of biomass and survival results to the amount of Zequanox applied showed that the lower concentrations and subsurface applications were more cost efficient, with respect to product used, at reducing zebra mussel biomass and for inducing zebra mussel mortality. Although the subsurface application methods and lower treatment concentrations were more cost efficient, biological significance and management goals should be evaluated prior to selecting the application method. Development and refinement of additional application techniques may improve the utility of the subsurface Zequanox applications.