Benedetto, Umberto; Taggart, David P; Sousa-Uva, Miguel; Biondi-Zoccai, Giuseppe; Di Franco, Antonino; Ohmes, Lucas B; Rahouma, Mohamed; Kamel, Mohamed; Caputo, Massimo; Girardi, Leonard N; Angelini, Gianni D; Gaudino, Mario
2018-05-01
With the advent of bare metal stents and drug-eluting stents, percutaneous coronary intervention has emerged as an alternative to coronary artery bypass grafting surgery for unprotected left main disease. However, whether the evolution of stents technology has translated into better results after percutaneous coronary intervention remains unclear. We aimed to compare coronary artery bypass grafting with stents of different generations for left main disease by performing a Bayesian network meta-analysis of available randomized controlled trials. All randomized controlled trials with at least 1 arm randomized to percutaneous coronary intervention with stents or coronary artery bypass grafting for left main disease were included. Bare metal stents and drug-eluting stents of first- and second-generation were compared with coronary artery bypass grafting. Poisson methods and Bayesian framework were used to compute the head-to-head incidence rate ratio and 95% credible intervals. Primary end points were the composite of death/myocardial infarction/stroke and repeat revascularization. Nine randomized controlled trials were included in the final analysis. Six trials compared percutaneous coronary intervention with coronary artery bypass grafting (n = 4654), and 3 trials compared different types of stents (n = 1360). Follow-up ranged from 6 months to 5 years. Second-generation drug-eluting stents (incidence rate ratio, 1.3; 95% credible interval, 1.1-1.6), but not bare metal stents (incidence rate ratio, 0.63; 95% credible interval, 0.27-1.4), and first-generation drug-eluting stents (incidence rate ratio, 0.85; 95% credible interval, 0.65-1.1) were associated with a significantly increased risk of death/myocardial infarction/stroke when compared with coronary artery bypass grafting. When compared with coronary artery bypass grafting, the highest risk of repeat revascularization was observed for bare metal stents (hazard ratio, 5.1; 95% confidence interval, 2.1-14), whereas first-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) and second-generation drug-eluting stents (incidence rate ratio, 1.8; 95% confidence interval, 1.4-2.4) were comparable. The introduction of new-generation drug-eluting stents did not translate into better outcomes for percutaneous coronary intervention when compared with coronary artery bypass grafting. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Angioplasty and stent placement - heart
PCI; Percutaneous coronary intervention; Balloon angioplasty; Coronary angioplasty; Coronary artery angioplasty; Percutaneous transluminal coronary angioplasty; Heart artery dilatation; Angina - stent placement; Acute coronary ...
Stent-induced coronary artery stenosis characterized by multimodal nonlinear optical microscopy
NASA Astrophysics Data System (ADS)
Wang, Han-Wei; Simianu, Vlad; Locker, Mattew J.; Cheng, Ji-Xin; Sturek, Michael
2011-02-01
We demonstrate for the first time the applicability of multimodal nonlinear optical (NLO) microscopy to the interrogation of stented coronary arteries under different diet and stent deployment conditions. Bare metal stents and Taxus drug-eluting stents (DES) were placed in coronary arteries of Ossabaw pigs of control and atherogenic diet groups. Multimodal NLO imaging was performed to inspect changes in arterial structures and compositions after stenting. Sum frequency generation, one of the multimodalities, was used for the quantitative analysis of collagen content in the peristent and in-stent artery segments of both pig groups. Atherogenic diet increased lipid and collagen in peristent segments. In-stent segments showed decreased collagen expression in neointima compared to media. Deployment of DES in atheromatous arteries inhibited collagen expression in the arterial media.
[Successful correction with stent-graft of coronary artery rupture after angioplasty].
Demin, V V
2003-01-01
Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.
Babunashvili, A M; Navtsishvili, Z G; Konstantinov, B A
2016-02-01
The authors present immediate and long term results of the first in Russia implantation in coronary artery of Palmaz-Shatz metal stent. Indications for stenting were urgent after complicated dissection as a result of balloon dilation of discrete bifurcational stenosis of anterior interventricular artery (IVA). Immediate angiographic and clinical result was good. At control angiography after 13 years their was no restenosis in stented IVA. However novel narrowing was found in left main coronary artery (LMCA) in which drug eluting stent was implanted. Coronary angiography carried out after 7.5 years after stenting of LMCA and in 20 years after stent implantation in IVA revealed good patency of both stented segments without signs of restenosis. This case report demonstrates possibility of long term preservation of angiographic and clinical effect of staged endovascular treatment of coronary atherosclerosis.
Yu, Yi; Zhou, Yujie; Ma, Qian; Jia, Shuo; Wu, Sijing; Sun, Yan; Liu, Xiaoli; Zhao, Yingxin; Liu, Yuyang; Shi, Dongmei
2017-01-15
This study sought to explore the efficacy of the conical stent implantation in the coronary artery by comparing the effects of cylindrical and conical stents on wall shear stress (WSS) and velocity of flow and fractional flow reserve (FFR). The traditional cylindrical stent currently used in the percutaneous coronary intervention (PCI) has a consistent diameter, which does not match the physiological change of the coronary artery. On the contrary, as a new patent, the conical stent with tapering lumen is consistent with the physiological change of vascular diameter. However, the effect of the conical stent implantation on the coronary hemodynamics remains unclear. The coronary artery, artery stenosis and two stent models were established by Solidworks software. All models were imported into the computational fluid dynamics (CFD) software ANSYS ICEM-CFD to establish the fluid model. After the boundary conditions were set, CFD analysis was proceeded to compare the effects of two stent implantation on the change of WSS, velocity of flow and FFR. Hemodynamic indexes including FFR, blood flow velocity distribution (BVD) and WSS were improved by either the cylindrical or the conical stent implantation. However, after the conical stent implantation, the change of FFR seemed to be slower and more homogenous; the blood flow velocity was more appropriate without any obvious blood stagnation and direction changes; the WSS after the conical stent implantation was uniform from the proximal to distal side of the stent. Compared with the cylindrical stent, the conical stent implantation in the coronary artery can make the changes of vascular hemodynamic more closer to the physiological condition, which can reduce the incidence of intra-stent restenosis and thrombosis, thus making it more suitable for PCI therapy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Design and modeling balloon-expandable coronary stent for manufacturability
NASA Astrophysics Data System (ADS)
Suryawan, D.; Suyitno
2017-02-01
Coronary artery disease (CAD) is a disease that caused by narrowing of the coronary artery. The narrowing coronary artery is usually caused by cholesterol-containing deposit (plaque) which can cause a heart attack. CAD is the most common cause mortality in Indonesia. The commonly CAD treatment use the stent to opens or alleviate the narrowing coronary artery. In this study, the stent design is optimized for the manufacturability. Modeling is used to determine the free stent expansion due to applied pressure in the inner surface of the stent. The stress distribution, outer diameter change, and dogboning phenomena are investigated in the simulation. The result of modeling and simulating was analyzed and used to optimize the stent design before it is manufactured using EDM (Electric Discharge Machine) in the next research.
NASA Astrophysics Data System (ADS)
Poon, Eric; Ooi, Andrew; Barlis, Peter; Hayat, Umair; Moore, Stephen
2014-11-01
Percutaneous coronary intervention (PCI) is the modern gold standard for treatment of coronary artery disease. Stenting (a common PCI procedure) of simple lesion inside a relatively straight segment of coronary artery has proven to be highly successful. However, incomplete stent apposition (ISA) where there is a lack of contact between the stent struts and lumen wall is not uncommon in curved and calcified coronary arteries. Computational fluid dynamics simulations are carried out to study the changes in hemodynamics as a result of ISA inside a curved and calcified coronary artery. For a 3 mm coronary artery, we simulate a resting condition at 80 mL/min and a range of hyperemic conditions with coronary flow reserve in between 1 and 2. The heartbeat is fixed at 75 BPM. Five different curvatures of the coronary artery are considered. Negative effects on hemodynamic variables, such as low wall shear stress (<0.5 Pa); high wall shear stress gradient (>5,000 Pa/m) and oscillation shear index (0 <= OSI <= 0.5), are employed to identify locations with high possibilities of adverse clinical events. This study will lead to better understandings of ISA in curved and calcified coronary arteries and help improve future coronary stent deployment. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).
Experimental Evaluation of a New Tubular Coronary Stent (V-Flexª).
Shun; Wang; Zhou; Verbeken; Ping; Szilard; Yanming; Jianhua; De Scheerder IK
1998-11-01
The safety, efficacy, angiographic and histological effects of a new 316 L, SS seamless stainless steel tubular stent (V-Flexª, Global Therapeutics, Broomfield, Colorado) was evaluated in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 16 pigs. Eight pigs were angiographically controlled after 6 weeks and then sacrificed for morphometric analysis. All stented coronary vessels were widely patent at this moment and morphometric analysis showed only a mild fibromuscular neointimal hyperplasia resulting in a neointimal hyperplasia of 1.15 +/- 0.38 mm2. The remaining 8 pigs were controlled and sacrificed at 12 weeks. At that time, all stented vessels were patent and neointimal hyperplasia was 1.22 +/- 0.34 mm2. Comparison with the Palmaz-Schatzª coronary stent (Cordis, Miami, Florida) in a porcine peripheral artery model demonstrated significantly less neointimal hyperplasia at 6 weeks (1.11 +/- 0.73 vs. 2.40 +/- 0.36, p = 0.001) and at 12 weeks (1.53 +/- 0.42 vs. 2.47 +/- 0.63, p = 0.003) for the V-Flex stent. In conclusion, V-Flex coronary stent implantation in a porcine coronary and peripheral arteries results in a high procedural success rate without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six and 12 week histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia. Comparison with the Palmaz-Schatz coronary stent in a peripheral artery model showed significantly less neointimal hyperplasia in the V-Flex stent.
Advances in drug eluting stents – focus on the Endeavor® zotarolimus stent
Bridges, Jonathan; Cutlip, Donald
2009-01-01
Coronary artery disease remains one of the leading causes of death in the United States. Over the last 30 years, the development of coronary artery angioplasty and stenting has drastically reduced mortality during acute coronary syndromes while also reducing symptoms of chronic coronary artery disease. Unfortunately, the placement of stents in a coronary artery can be complicated by in-stent thrombosis or restenosis. In 2003–2004, a new generation of stents was introduced to the market with the goal of reducing the rate of restenosis. These stents, called drug eluting stents (DES), are coated with a pharmacological agent designed to reduce the neointimal hyperplasia associated with restenosis. Within a year, approximately 80% of all percutaneous coronary interventions performed within the US involved placement of a DES. In 2006, a controversy arose about the possibility of a statistically significant increased risk of acute stent thrombosis associated with DES especially when used for an “off label” indication. This risk was attributed to delayed endothelization. This controversy has led to a reduction in the use of DES along with longer use of dual platelet inhibition with aspirin and clopidogrel. Recently Medtronic introduced a new DES to the market called the Endeavor® stent – a zotarolimus eluting stent. PMID:22915908
NASA Astrophysics Data System (ADS)
Boland, Enda L.; Grogan, James A.; Conway, Claire; McHugh, Peter E.
2016-04-01
Coronary stents have revolutionised the treatment of coronary artery disease. While coronary artery stenting is now relatively mature, significant scientific and technological challenges still remain. One of the most fertile technological growth areas is biodegradable stents; here, there is the possibility to generate stents that will break down in the body once the initial necessary scaffolding period is past (6-12 months) (Grogan et al. in Acta Biomater 7:3523, 2011) and when the artery has remodelled (including the formation of neo-intima). A stent angioplasty computational test-bed has been developed by the authors, based on the Abaqus software (DS-SIMULIA, USA), capable of simulating stent tracking, balloon expansion, recoil and in vivo loading in a atherosclerotic artery model. Additionally, a surface corrosion model to simulate uniform and pitting corrosion of biodegradable stents and a representation of the active response of the arterial tissue following stent implantation, i.e. neointimal remodelling, has been developed. The arterial neointimal remodelling simulations with biodegradable stent corrosion demonstrate that the development of new arterial tissue around the stent struts has a substantial effect on the mechanical behaviour of degrading stents.
Treatment of a coronary artery aneurysm by use of a covered stent graft – a case report
Gundoğdu, Fuat; Arslan, Sakir; Buyukkaya, Eyup; Senocak, Huseyin
2007-01-01
Coronary artery aneurysm is a rare finding at coronary angiography. Most coronary aneurysms remain asymptomatic. There is no consensus on its management; some advocate aggressive approach while others advocate conservative management. A case of coronary artery aneurysm successfully treated by implantation of a polytetrafluoroethylene-covered coronary stent is presented. PMID:22477247
Auxetic coronary stent endoprosthesis: fabrication and structural analysis.
Amin, Faisal; Ali, Murtaza Najabat; Ansari, Umar; Mir, Mariam; Minhas, Muhammad Asim; Shahid, Wakeel
2015-07-04
Cardiovascular heart disease is one of the leading health issues in the present era and requires considerable health care resources to prevent it. The present study was focused on the development of a new coronary stent based on novel auxetic geometry which enables the stent to exhibit a negative Poisson's ratio. Commercially available coronary stents have isotropic properties, whereas the vascular system of the body shows anisotropic characteristics. This results in a mismatch between anisotropic-isotropic properties of the stent and arterial wall, and this in turn is not favorable for mechanical adhesion of the commercially available coronary stents with the arterial wall. It is believed that an auxetic coronary stent with inherent anisotropic mechanical properties and negative Poisson's ratio will have good mechanical adhesion with the arterial wall. The auxetic design was obtained via laser cutting, and surface treatment was performed with acid pickling and electropolishing, followed by an annealing process. In vitro mechanical analysis was performed to analyze the mechanical performance of the auxetic coronary stent. Scanning electronic microscopy (SEM) was used to determine the effects of fabrication processes on the topography of the auxetic stent. The elastic recoil (3.3%) of the in vitro mechanical analysis showed that the auxetic stent design effectively maintained the luminal patency of the coronary artery. Also, the auxetic coronary stent showed no foreshortening, therefore it avoids the problem of stent migration, by expanding in both the radial and longitudinal directions. By virtue of its synclastic behavior, the auxetic stent bulges outward when it is radially expanded through an inflated balloon.
Gambhir, D S; Batra, R; Singh, S; Sudha, R; Trehen, V; Arora, R
1998-01-01
Lesions at the ostium of the left anterior descending coronary artery constitute a distinct group because of suboptimal results and higher restenosis rate after balloon angioplasty. Several non-balloon devices have been used to improve the outcome of dilatation of such lesions. We retrospectively compared the in-hospital and follow-up results of directional coronary artherectomy and stents for the treatment of ostial lesions of the left anterior descending artery. Out of 37 patients, 12 underwent directional coronary atherectomy and 25, stent implantation. The two strategies were deployed at different periods over the past five years. The baseline clinical and angiographic characteristics were comparable in the two groups. Directional coronary atherectomy was done using 7Fr atherocath with adjunctive balloon angioplasty in all. All the stents were deployed using moderate to high pressure balloon inflation after adequate predilatation. While the pre-procedure luminal diameter stenosis was similar in the two groups (87.3 +/- 8.8% vs 89.3 +/- 7.2%; p = NS), the residual stenosis was significantly lower in the stent group (5 +/- 2.8%) compared to directional coronary atherectomy (18.7 +/- 9.8; p = 0.02). There was no significant difference in the primary success rate between the two devices (91.6% directional coronary atherectomy vs 100% stent; p = NS). One patient in the directional coronary atherectomy group developed acute closure followed by emergency coronary artery bypass graft surgery and death. No major complication was observed in the stent group. Over a mean follow-up of 9.9 +/- 11.6 months following directional coronary atherectomy and 8.6 +/- 4.4 months after stenting, significantly higher number of patients (60%) developed recurrence of angina or any event following directional coronary atherectomy compared to stent (15.8%; p < 0.02). There was no myocardial infarction, coronary artery bypass graft surgery or death in either group on follow-up. The need for target lesion revascularisation was significantly higher in the directional coronary atherectomy group (50%) compared to stenting (10.5%; p < 0.02). Comparing directional coronary atherectomy with stent, the event-free survival was 80 percent vs 94.7 percent at three months and 50 percent vs 84.7 percent, both at six and nine months, respectively. In conclusion, stenting of the left anterior descending artery ostial lesion results in a significantly lesser post-procedure residual stenosis, improved in-hospital outcome, a lesser need for target lesion revascularisation and much improved event-free survival on follow-up as compared to directional coronary atherectomy. Therefore, stenting appears to be a more favourable treatment option compared to directional coronary atherectomy for the treatment of ostial lesions in the left anterior descending artery.
Stortecky, Stefan; Stefanini, Giulio G; daCosta, Bruno R; Rutjes, Anne Wilhelmina; Di Nisio, Marcello; Siletta, Maria G; Maione, Ausilia; Alfonso, Fernando; Clemmensen, Peter M; Collet, Jean-Philippe; Cremer, Jochen; Falk, Volkmar; Filippatos, Gerasimos; Hamm, Christian; Head, Stuart; Kappetein, Arie Pieter; Kastrati, Adnan; Knuuti, Juhani; Landmesser, Ulf; Laufer, Günther; Neumann, Franz-Joseph; Richter, Dimitri; Schauerte, Patrick; Sousa Uva, Miguel; Taggart, David P; Torracca, Lucia; Valgimigli, Marco; Wijns, William; Witkowski, Adam; Kolh, Philippe; Juni, Peter
2014-01-01
Objective To investigate whether revascularisation improves prognosis compared with medical treatment among patients with stable coronary artery disease. Design Bayesian network meta-analyses to combine direct within trial comparisons between treatments with indirect evidence from other trials while maintaining randomisation. Eligibility criteria for selecting studies A strategy of initial medical treatment compared with revascularisation by coronary artery bypass grafting or Food and Drug Administration approved techniques for percutaneous revascularization: balloon angioplasty, bare metal stent, early generation paclitaxel eluting stent, sirolimus eluting stent, and zotarolimus eluting (Endeavor) stent, and new generation everolimus eluting stent, and zotarolimus eluting (Resolute) stent among patients with stable coronary artery disease. Data sources Medline and Embase from 1980 to 2013 for randomised trials comparing medical treatment with revascularisation. Main outcome measure All cause mortality. Results 100 trials in 93 553 patients with 262 090 patient years of follow-up were included. Coronary artery bypass grafting was associated with a survival benefit (rate ratio 0.80, 95% credibility interval 0.70 to 0.91) compared with medical treatment. New generation drug eluting stents (everolimus: 0.75, 0.59 to 0.96; zotarolimus (Resolute): 0.65, 0.42 to 1.00) but not balloon angioplasty (0.85, 0.68 to 1.04), bare metal stents (0.92, 0.79 to 1.05), or early generation drug eluting stents (paclitaxel: 0.92, 0.75 to 1.12; sirolimus: 0.91, 0.75 to 1.10; zotarolimus (Endeavor): 0.88, 0.69 to 1.10) were associated with improved survival compared with medical treatment. Coronary artery bypass grafting reduced the risk of myocardial infarction compared with medical treatment (0.79, 0.63 to 0.99), and everolimus eluting stents showed a trend towards a reduced risk of myocardial infarction (0.75, 0.55 to 1.01). The risk of subsequent revascularisation was noticeably reduced by coronary artery bypass grafting (0.16, 0.13 to 0.20) followed by new generation drug eluting stents (zotarolimus (Resolute): 0.26, 0.17 to 0.40; everolimus: 0.27, 0.21 to 0.35), early generation drug eluting stents (zotarolimus (Endeavor): 0.37, 0.28 to 0.50; sirolimus: 0.29, 0.24 to 0.36; paclitaxel: 0.44, 0.35 to 0.54), and bare metal stents (0.69, 0.59 to 0.81) compared with medical treatment. Conclusion Among patients with stable coronary artery disease, coronary artery bypass grafting reduces the risk of death, myocardial infarction, and subsequent revascularisation compared with medical treatment. All stent based coronary revascularisation technologies reduce the need for revascularisation to a variable degree. Our results provide evidence for improved survival with new generation drug eluting stents but no other percutaneous revascularisation technology compared with medical treatment. PMID:24958153
2018-03-01
Chronic Coronary Occlusion; Unprotected Left Main Coronary Artery Disease; Stent Thrombosis; Vascular Disease; Myocardial Ischemia; Coronary Artery Stenosis; Coronary Disease; Coronary Artery Disease; Coronary Restenosis
Drug- and Gene-eluting Stents for Preventing Coronary Restenosis
Lekshmi, Kamali Manickavasagam; Che, Hui-Lian; Cho, Chong-Su
2017-01-01
Coronary artery disease (CAD) has been reported to be a major cause of death worldwide. Current treatment methods include atherectomy, coronary angioplasty (as a percutaneous coronary intervention), and coronary artery bypass. Among them, the insertion of stents into the coronary artery is one of the commonly used methods for CAD, although the formation of in-stent restenosis (ISR) is a major drawback, demanding improvement in stent technology. Stents can be improved using the delivery of DNA, siRNA, and miRNA rather than anti-inflammatory/anti-thrombotic drugs. In particular, genes that could interfere with the development of plaque around infected regions are conjugated on the stent surface to inhibit neointimal formation. Despite their potential benefits, it is necessary to explore the various properties of gene-eluting stents. Furthermore, multifunctional electronic stents that can be used as a biosensor and deliver drug- or gene-based on physiological condition will be a very promising way to the successful treatment of ISR. In this review, we have discussed the molecular mechanism of restenosis, the use of drug- and gene-eluting stents, and the possible roles that these stents have in the prevention and treatment of coronary restenosis. Further, we have explained how multifunctional electronic stents could be used as a biosensor and deliver drugs based on physiological conditions. PMID:28184335
Molecular intravascular imaging approaches for atherosclerosis.
Press, Marcella Calfon; Jaffer, Farouc A
2014-10-01
Coronary artery disease (CAD) is an inflammatory process that results in buildup of atherosclerosis, typically lipid-rich plaque in the arterial wall. Progressive narrowing of the vessel wall and subsequent plaque rupture can lead to myocardial infarction and death. Recent advances in intravascular fluorescence imaging techniques have provided exciting coronary artery-targeted platforms to further characterize the molecular changes that occur within the vascular wall as a result of atherosclerosis and following coronary stent-induced vascular injury. This review will summarize exciting recent developments in catheter-based imaging of coronary arterial-sized vessels; focusing on two-dimensional near-infrared fluorescence imaging (NIRF) molecular imaging technology as an approach to specifically identify inflammation and fibrin directly within coronary artery-sized vessels. Intravascular NIRF is anticipated to provide new insights into the in vivo biology underlying high-risk plaques, as well as high-risks stents prone to stent restenosis or stent thrombosis.
Arisha, Mohammed J; Hsiung, Ming C; Ahmad, Amier; Nanda, Navin C; Elkaryoni, Ahmed; Mohamed, Ahmed H; Yin, Wei-Hsian
2017-06-01
Ostial lesions represent a challenging clinical scenario and percutaneous intervention (PCI) of left main coronary artery ostial lesions has been associated with postintervention complications, including protrusion of deployed stents into a sinus of Valsalva or aortic root. We report a case of stent protrusion into the aortic root following aorto-ostial left main coronary artery PCI, in which three-dimensional transesophageal echocardiography (3DTEE) provided incremental benefit over standard two-dimensional images. Specifically, 3DTEE confirmed the presence of stent protrusion by allowing clear visualization of the stent scaffold, in addition to characterizing the relationship between the stent and surrounding structures. © 2017, Wiley Periodicals, Inc.
Alam, M; Safi, A M; Mandawat, M K; Anderson, J E; Kwan, T; Feit, A; Clark, L T
2000-02-01
The right gastroepiploic artery (RGEA) is being successfully used as an arterial conduit in a selected group of patients undergoing coronary artery bypass graft surgery. However, myocardial ischemia may result due to spasm, occlusion, and stenosis of this graft. The anastamosis site at distal right coronary artery (RCA) or posterior descending artery (PDA) is the most common location for stenosis of an in situ gastroepiploic coronary bypass graft. Balloon angioplasty of such stenoses has been reported with optimal short-term results. Stent deployment would decrease the restenosis rate, so that repeat procedures could be minimized for these technically challenging lesions. We describe a case of successful deployment of a stent with monorail delivery system at the anastamotic site stenosis of an in situ gastroepiploic right coronary artery bypass graft. This percutaneous coronary intervention could prevent redo coronary artery bypass graft surgery. Cathet. Cardiovasc. Intervent. 49:197-199, 2000. Copyright 2000 Wiley-Liss, Inc.
Taggart, David P; Amin, Sanaz; Djordjevic, Jasmina; Oikonomou, Evangelos K; Thomas, Sheena; Kampoli, Anna-Maria; Sabharwal, Nikant; Antoniades, Charalambos; Krasopoulos, George
2017-05-01
External stents significantly reduce intimal hyperplasia and improve lumen uniformity and flow pattern in saphenous vein grafts (SVG) 1 year after coronary artery bypass grafting. However, recent studies have shown that at 1 year there is a lower patency of externally stented SVG to the right coronary artery (RCA) (55-60%) when compared to the left sided coronary arteries (85-90%). In the current study, we investigated whether avoidance of both fixation of the external stent to the anastomoses and the use of metal clips to ligate SVG side branches would improve the early patency of externally stented SVG to the RCA. Thirty patients received a SVG to the right territory supported with an external stent. Graft patency was confirmed at the end of surgery in all patients. The primary endpoint was SVG patency assessed by computed tomography angiography (CTA) at 3-6 months. Graft failure was defined as > 50% stenosis. Twenty-nine patients (96.6%) completed the follow up period and CT angiography data was available for a total of 43 SVGs, (29 supported and 14 unsupported SVGs) and 47 arterial grafts. Patency of stented SVGs was 86.2% (25/29 on CTA). All non-stented SVGs to the left territory were patent. Patency rates of the left internal mammary arteries and right internal mammary arteries grafts were 96.6% and 83.3%, respectively. Avoidance of both metallic clips to ligate side branches and of fixation of venous external support trial (VEST) stents to the anastomoses mark a significant improvement in patency of stented SVG to the right coronary territory. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Role of Animal Models in Coronary Stenting.
Iqbal, Javaid; Chamberlain, Janet; Francis, Sheila E; Gunn, Julian
2016-02-01
Coronary angioplasty initially employed balloon dilatation only. This technique revolutionized the treatment of coronary artery disease, although outcomes were compromised by acute vessel closure, late constrictive remodeling, and restenosis due to neointimal proliferation. These processes were studied in animal models, which contributed to understanding the biology of endovascular arterial injury. Coronary stents overcome acute recoil, with improvements in the design and metallurgy since then, leading to the development of drug-eluting stents and bioresorbable scaffolds. These devices now undergo computer modeling and benchtop and animal testing before evaluation in clinical trials. Animal models, including rabbit, sheep, dog and pig are available, all with individual benefits and limitations. In smaller mammals, such as mouse and rabbit, the target for stenting is generally the aorta; whereas in larger animals, such as the pig, it is generally the coronary artery. The pig coronary stenting model is a gold-standard for evaluating safety; but insights into biomechanical properties, the biology of stenting, and efficacy in controlling neointimal proliferation can also be gained. Intra-coronary imaging modalities such as intravascular ultrasound and optical coherence tomography allow precise serial evaluation in vivo, and recent developments in genetically modified animal models of atherosclerosis provide realistic test beds for future stents and scaffolds.
Angioplasty and stent - heart - discharge
Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...
Chen, Mounter C Y; Lu, Po-Chien; Chen, James S Y; Hwang, Ned H C
2005-01-01
Coronary stents are supportive wire meshes that keep narrow coronary arteries patent, reducing the risk of restenosis. Despite the common use of coronary stents, approximately 20-35% of them fail due to restenosis. Flow phenomena adjacent to the stent may contribute to restenosis. Three-dimensional computational fluid dynamics (CFD) and reconstruction based on biplane cine angiography were used to assess coronary geometry and volumetric blood flows. A patient-specific left anterior descending (LAD) artery was reconstructed from single-plane x-ray imaging. With corresponding electrocardiographic signals, images from the same time phase were selected from the angiograms for dynamic three-dimensional reconstruction. The resultant three-dimensional LAD artery at end-diastole was adopted for detailed analysis. Both the geometries and flow fields, based on a computational model from CAE software (ANSYS and CATIA) and full three-dimensional Navier-Stroke equations in the CFD-ACE+ software, respectively, changed dramatically after stent placement. Flow fields showed a complex three-dimensional spiral motion due to arterial tortuosity. The corresponding wall shear stresses, pressure gradient, and flow field all varied significantly after stent placement. Combined angiography and CFD techniques allow more detailed investigation of flow patterns in various segments. The implanted stent(s) may be quantitatively studied from the proposed hemodynamic modeling approach.
Hybrid coronary revascularization in the era of drug-eluting stents.
Murphy, Gavin J; Bryan, Alan J; Angelini, Gianni D
2004-11-01
Left internal mammary artery to left anterior descending coronary artery bypass grafting integrated with percutaneous coronary angioplasty (hybrid procedure) offers multivessel revascularization with minimal morbidity in high-risk patients. This is caused in part by the avoidance of cardiopulmonary bypass-related morbidity and manipulation of the aorta coupled with minimally invasive techniques. Hybrid revascularization is currently reserved for particularly high-risk patients or those with favorable anatomic variants however, largely because of the emergence of off-pump coronary artery bypass grafting, which permits more complete multivessel revascularization, with low morbidity in high-risk groups. The wider introduction of hybrid revascularization is limited chiefly by the high number of repeat interventions compared with off-pump coronary artery bypass grafting, which occurs because of the target vessel failure rate of percutaneous coronary intervention. Other demerits are the costs and logistic problems associated with performing two procedures with differing periprocedural management protocols. Recently, drug-eluting stents have reduced the need for repeat intervention after percutaneous coronary intervention, and this has raised the possibility that the results of hybrid revascularization may now equal or even better those of off-pump coronary artery bypass grafting. Although undoubtedly effective at reducing in-stent restenosis, drug-eluting stents will not address the issues of incomplete revascularization or the logistic problems associated with hybrid. Uncertainty regarding the long-term effectiveness of drug-eluting stents in many patients, as well as their high cost when compared with those of off-pump coronary artery bypass grafting surgery, also militates against the wider introduction of hybrid revascularization.
Wykrzykowska, Joanna J; Carrozza, Joseph; Laham, Roger J
2006-08-01
Iatrogenic aortocoronary dissection is a rare but devastating complication of percutaneous coronary interventions and cardiac surgery, with a mortality rate up to 35%. Of the type-A dissections in the International Registry of Aortic Dissections (IRAD), 27% were caused by coronary interventions. The mechanism involves an initial dissection in the coronary artery, which then propagates in a retrograde fashion past the sinuses of Valsalva, often several centimeters beyond the aortic valve. With the advent of complex interventions such as left main stent implantation, revascularization of chronic total occlusions and mechanical thrombectomy, this complication may become more prevalent. Here we present a unique case of percutaneous coronary intervention (PCI) of the left circumflex (LCx) artery complicated by a left main coronary dissection that propagated approximately 8 cm into the ascending aorta and caused abrupt left main coronary artery occlusion and hemodynamic collapse. Rescue of the left main artery and sealing of the aortic dissection with stabilization of the patient was possible with rapid ostial left main artery stenting.
Stenting and surgery for coronary vasospasm : the wrong solution fails to solve the problem.
Nedeljkovic, Milan A; Ostojic, Miodrag; Lalic, Nebojsa; Beleslin, Branko; Nedeljkovic, Ivana; Lalic, Katarina; Ristic, Miljko; Giga, Vojislav; Angelkov, Lazar; Tomasevic, Miloje; Kanjuh, Vladimir
2009-11-01
A 55-year-old man, with a history of medically uncontrolled coronary vasospasm, presented for evaluation of chest pain 6 months after implantation of left internal mammary artery. Due to recurrent episodes of vasospastic angina and serious complications of coronary spasm (ventricular fibrillation, myocardial infarction), a stent had previously been implanted in the proximal part of left anterior descending artery at the site of angiographically and ergonovine-proven coronary spasm, with subsequent in-stent restenosis.
Computational fluid dynamics evaluation of incomplete stent apposition in a tapered artery
NASA Astrophysics Data System (ADS)
Poon, Eric; Thondapu, Vikas; Ooi, Andrew; Hayat, Umair; Barlis, Peter; Moore, Stephen
2015-11-01
Coronary stents are deployed to prop open blocked arteries and restore normal blood flow, however in-stent restenosis (ISR) and stent thrombosis (ST) remain possibly catastrophic complications. Computational fluid dynamics (CFD) analyses can elucidate the pathological impact of alterations in coronary hemodynamics and correlate wall shear stress (WSS) with atherosclerotic processes. The natural tapering of a coronary artery often leads to proximal incomplete stent apposition (ISA) where stent struts are not in contact with the vessel wall. By employing state-of-the-art computer-aided design (CAD) software, generic open-cell and closed-cell coronary stent designs were virtually deployed in an idealised tapered coronary artery. Pulsatile blood flow (80 mL/min at 75 beats/min) was carried out numerically on these CAD models using a finite volume solver. CFD results reveal significant fluctuations in proximal WSS and large recirculation regions in the setting of proximal ISA, resulting in regions of high wall shear stress gradient (WSSG) that have been previously linked to poor endothelial cell coverage and vascular injury. The clinical significance of these proximal high WSSG regions will be correlated with findings from high-resolution in-vivo imaging. Supported by the Australian Research Council (LP120100233) and Victorian Life Sciences Computation Initiative (VR0210).
Keyes, Joseph T.; Simon, Bruce R.; Vande Geest, Jonathan P.
2013-01-01
Drug-eluting stents have a significant clinical advantage in late-stage restenosis due to the antiproliferative drug release. Understanding how drug transport occurs between coronary arterial locations can better help guide localized drug treatment options. Finite element models with properties from specific porcine coronary artery sections (left anterior descending (LAD), right (RCA); proximal, middle, distal regions) were created for stent deployment and drug delivery simulations. Stress, strain, pore fluid velocity, and drug concentrations were exported at different time points of simulation (0–180 days). Tests indicated that the highest stresses occurred in LAD sections. Higher-than-resting homeostatic levels of stress and strain existed at upwards of 3. mm away from the stented region, whereas concentration of species only reached 2.7 mm away from the stented region. Region-specific concentration showed 2.2 times higher concentrations in RCA artery sections at times corresponding to vascular remodeling (peak in the middle segment) compared to all other segments. These results suggest that wall transport can occur differently based on coronary artery location. Awareness of peak growth stimulators and where drug accumulation occurs in the vasculature can better help guide local drug delivery therapies. PMID:23699720
Park, Duk-Woo; Park, Seung-Jung
2017-06-01
For nearly half a century, coronary artery bypass grafting has been the standard treatment for patients with obstructive left main coronary artery (LMCA) disease. However, there has been considerable evolution in the field of percutaneous coronary intervention, and especially, percutaneous coronary intervention for LMCA disease has been rapidly expanded with adoption of drug-eluting stents. Some, but not all randomized trials, have shown that percutaneous coronary intervention with drug-eluting stents might be a suitable alternative for selected patients with LMCA disease instead of bypass surgery. However, none of previous trials involving early-generation drug-eluting stents was sufficiently powered and comparative trials using contemporary drug-eluting stents were limited. Recently, primary results of 2 new trials of EXCEL (Evaluation of XIENCE Everolimus Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) and NOBLE (Nordic-Baltic-British Left Main Revascularization Study) were reported. However, these trials showed conflicting results, which might pose uncertainty on the optimal revascularization strategy for LMCA disease. In this article, with the incorporation of a key review on evolution of LMCA treatment, we summarize the similarity or disparity of the EXCEL and NOBLE trials, focus on how they relate to previous trials in the field, and finally speculate on how the treatment strategy may be changed or recommended for LMCA treatment. © 2017 American Heart Association, Inc.
Cui, Xiaoming; Li, Tao; Li, Xin; Zhou, Weihua
2015-05-01
The aim of this study was to evaluate the in vivo performance of four image reconstruction algorithms in a high-definition CT (HDCT) scanner with improved spatial resolution for the evaluation of coronary artery stents and intrastent lumina. Thirty-nine consecutive patients with a total of 71 implanted coronary stents underwent coronary CT angiography (CCTA) on a HDCT (Discovery CT 750 HD; GE Healthcare) with the high-resolution scanning mode. Four different reconstruction algorithms (HD-stand, HD-detail; HD-stand-plus; HD-detail-plus) were applied to reconstruct the stented coronary arteries. Image quality for stent characterization was assessed. Image noise and intrastent luminal diameter were measured. The relationship between the measurement of inner stent diameter (ISD) and the true stent diameter (TSD) and stent type were analysed. The stent-dedicated kernel (HD-detail) offered the highest percentage (53.5%) of good image quality for stent characterization and the highest ratio (68.0±8.4%) of visible stent lumen/true stent lumen for luminal diameter measurement at the expense of an increased overall image noise. The Pearson correlation coefficient between the ISD and TSD measurement and spearman correlation coefficient between the ISD measurement and stent type were 0.83 and 0.48, respectively. Compared with standard reconstruction algorithms, high-definition CT imaging technique with dedicated high-resolution reconstruction algorithm provides more accurate stent characterization and intrastent luminal diameter measurement. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Bioresorbable Scaffolds: Current Evidences in the Treatment of Coronary Artery Disease
2016-01-01
Percutaneous coronary revascularization strategies have gradually progressed over a period of last few decades. The advent of newer generation drug-eluting stents has significantly improved the outcomes of Percutaneous Coronary Intervention (PCI) by substantially reducing in-stent restenosis and stent thrombosis. However, vascular inflammation, restenosis, thrombosis, and neoatherosclerosis due to the permanent presence of a metallic foreign body within the artery limit their usage in complex Coronary Artery Disease (CAD). Bioresorbable Scaffolds (BRS) represent a novel approach in coronary stent technology. Complete resorption of the scaffold liberates the treated vessel from its cage and restores pulsatility, cyclical strain, physiological shear stress, and mechanotransduction. In this review article, we describe the advances in this rapidly evolving technology, present the evidence from the pre-clinical and clinical evaluation of these devices, and provide an overview of the ongoing clinical trials that were designed to examine the effectiveness of BRS in the clinical setting. PMID:27891384
Stent design favorably influences the vascular response in normal porcine coronary arteries.
Carter, A J; Scott, D; Rahdert, D; Bailey, L; De Vries J; Ayerdi, K; Turnlund, T; Jones, R; Virmani, R; Fischell, T A
1999-03-01
The purpose of this study was to compare the arterial response following implantation of a stainless-steel, balloon-expandable, tubular slotted stent with that of a novel computer-designed, multi-cellular stent in normal porcine coronary arteries. Intracoronary stent placement has evolved into the primary strategy for percutaneous revascularization of symptomatic coronary arterial lesions. Presently there is intense interest in developing new stent designs to improve stent delivery and biocompatability. Computer-assisted design was utilized to develop a balloon-expandable stent with symmetric expansion properties, uniform arterial wall coverage, longitudinal flexibility and radial strength. Quantitative coronary angiography and histological assessment of the stented arteries was used to evaluate the acute and chronic vascular responses to a stainless-steel, balloon-expandable, tubular slotted stent as compared to the computer-designed BX stent in the normolipemic swine. Forty stents (24 BX, 16 tubular slotted) were implanted in 19 miniature swine at a mean inflation pressure of 9 atm using identical delivery systems. Eight of the BX and none of the tubular slotted stents were post-dilated with a non-compliant balloon at 12-14 atm. The mean stent-to-artery ratio was similar for the BX (1.03 +/- 0.06) and tubular slotted (1.04 +/- 0.11; p = 0.59) designs. Protrusion or asymmetric radial flaring of a strut at the stent margin was present in 1 of 23 BX stents (4.3%) and 10 of 15 tubular slotted stents (66.7%; p < 0.0001). The mean arterial injury score was significantly less for the BX stent (0.2 +/- 0.2) as compared with the tubular slotted stents (0.4 +/- 0.4; p = 0.025). At 3 days, thrombus area was similar for the BX and tubular slotted designs (0.42 +/- 0.16 mm2 versus 0.44 +/- 0.18 mm2, respectively; p = 0.88). The mean neointimal area was significantly less for the BX at 2 months (1.09 +/- 0.25 mm2 versus 2.93 +/- 2.26 mm2 in the tubular slotted stent) and at 6 months (1.10 +/- 0.26 mm2 versus 2.07 +/- 0.65 mm2 in the tubular slotted stent; p = 0.01), resulting in approximately 50% less in-stent stenosis. The arterial response to a balloon-expandable stent can be favorably influenced by computer-assisted modification of design in an experimental model. Further study is warranted to determine the impact of stent design upon clinical in-stent restenosis.
Lu, Huangling; de Winter, Robbert J; Koch, Karel T
2018-06-21
Coronary stent designs have been through extensive developments in the past few decades. Since the first introduction of the self-apposing STENTYS stent, several theoretical advantages of its nitinol platform have been clinically evaluated. This paper reviews the current status, ongoing work and future directions of this device. Areas covered: The OPEN (STENTYS Coronary Bifurcation Stent System fOr the PErcutaNeous treatment of de novo lesions in native bifurcated coronary arteries) trials revealed high technical success rates of the STENTYS performance in bifurcation lesions. The APPOSITION (Assessment of the Safety and Performance of the STENTYS self-expanding Coronary Stent in Acute Myocardial Infarction) trials demonstrated the safety and feasibility of the device in patients with acute myocardial infarction. Optical coherence tomography showed better short-term strut apposition in patients treated with the STENTYS stent in APPOSITION IV. The clinical outcomes of the device in saphenous vein graft lesions and left main coronary artery disease are favourable. Expert Commentary: Despite numerous theoretical advantages of the nitinol platform, superiority of the STENTYS self-apposing stent over currently available DES has not yet been proven. However, the ongoing registries evaluating the performance of the STENTYS Xposition will provide more insights in its clinical performance.
Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna
2002-03-01
A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.
LaDisa, John F; Olson, Lars E; Douglas, Hettrick A; Warltier, David C; Kersten, Judy R; Pagel, Paul S
2006-06-16
The success of stent implantation in the restoration of blood flow through areas of vascular narrowing is limited by restenosis. Several recent studies have suggested that the local geometric environment created by a deployed stent may influence regional blood flow characteristics and alter distributions of wall shear stress (WSS) after implantation, thereby rendering specific areas of the vessel wall more susceptible to neointimal hyperplasia and restenosis. Stents are most frequently implanted in curved vessels such as the coronary arteries, but most computational studies examining blood flow patterns through stented vessels conducted to date use linear, cylindrical geometric models. It appears highly probable that restenosis occurring after stent implantation in curved arteries also occurs as a consequence of changes in fluid dynamics that are established immediately after stent implantation. In the current investigation, we tested the hypothesis that acute changes in stent-induced regional geometry influence distributions of WSS using 3D coronary artery CFD models implanted with stents that either conformed to or caused straightening of the primary curvature of the left anterior descending coronary artery. WSS obtained at several intervals during the cardiac cycle, time averaged WSS, and WSS gradients were calculated using conventional techniques. Implantation of a stent that causes straightening, rather than conforms to the natural curvature of the artery causes a reduction in the radius of curvature and subsequent increase in the Dean number within the stented region. This straightening leads to modest skewing of the velocity profile at the inlet and outlet of the stented region where alterations in indices of WSS are most pronounced. For example, time-averaged WSS in the proximal portion of the stent ranged from 8.91 to 11.7 dynes/cm2 along the pericardial luminal surface and 4.26 to 4.88 dynes/cm2 along the myocardial luminal surface of curved coronary arteries as compared to 8.31 dynes/cm2 observed throughout the stented region of a straight vessel implanted with an equivalent stent. The current results predicting large spatial and temporal variations in WSS at specific locations in curved arterial 3D CFD simulations are consistent with clinically observed sites of restenosis. If the findings of this idealized study translate to the clinical situation, the regional geometry established immediately after stent implantation may predispose portions of the stented vessel to a higher risk of neointimal hyperplasia and subsequent restenosis.
Behaviour of two typical stents towards a new stent evolution.
Simão, M; Ferreira, J M; Mora-Rodriguez, J; Fragata, J; Ramos, H M
2017-06-01
This study explores the analysis of a new stent geometry from two typical stents used to treat the coronary artery disease. Two different finite element methods are applied with different boundary conditions to investigate the stenosis region. Computational fluid dynamics (CFD) models including fluid-structure interaction are used to assess the haemodynamic impact of two types of coronary stents implantation: (1) type 1-based on a strut-link stent geometry and (2) type 2-a continuous helical stent. Using data from a recent clinical stenosis, flow disturbances and consequent shear stress alterations introduced by the stent treatment are investigated. A relationship between stenosis and the induced flow fields for the two types of stent designs is analysed as well as the correlation between haemodynamics and vessel wall biomechanical factors during the initiation and development of stenosis formation in the coronary artery. Both stents exhibit a good performance in reducing the obstruction artery. However, stent type 1 presents higher radial deformation than the type 2. This deformation can be seen as a limitation with a long-term clinical impact.
Coronary Stents: The Impact of Technological Advances on Clinical Outcomes.
Mennuni, Marco G; Pagnotta, Paolo A; Stefanini, Giulio G
2016-02-01
Percutaneous coronary interventions (PCI) were proposed in the late 1970s as an alternative to surgical coronary artery bypass grafting for the treatment of coronary artery disease. Important technological progress has been made since. Balloon angioplasty was replaced by bare metal stents, which allowed to permanently scaffold the coronary vessel avoiding acute recoil and abrupt occlusion. Thereafter, the introduction of early generation drug-eluting stents (DES) has significantly improved clinical outcomes, primarily by markedly reducing the risk of restenosis. New generation DES with thinner stent struts, novel durable or biodegradable polymer coatings, and new limus antiproliferative agents, have further improved upon the safety and efficacy profile of early generation DES. The present article aims to review the impact of technological advances on clinical outcomes in the field of PCI with coronary stents, and to provide a brief overview on clinical margins of improvement and unmet needs of available DES.
Bioabsorbable coronary stents--are these the next big thing in coronary angioplasty?
Balla, Sudarshan; Aggarwal, Kul; Nistala, Ravi
2010-06-01
The role of percutaneous coronary intervention (PCI) in the treatment of coronary artery disease has grown at an astronomical pace. Drug eluting stents (DES) offer advantages over bare metal stents (BMS) such as reduction in early in-stent restenosis rates. However, they have disadvantages like from increased late stent thrombosis when compared with BMS. Furthermore, recent data suggest endothelial dysfunction in the DES stented segments of the arteries. Currently, bioabsorbable stents are under development to avert the complications of DES such as stent thrombosis via degradation of the stent over time. The hypothetical advantage of leaving behind a natural vessel and restoring vasoreactivity may be the almost normal physiology which can be achieved after an intervention with a stent. The ABSORB and the PROGRESS AMS are two of the recent clinical trials that have looked at the outcomes of using bioabsorbable stents. So far, data from these and other studies has yielded mixed results in terms of angiographic and clinical outcomes. Newer stents such as REVA and WHISPER are presently being tested in preclinical and clinical trials. The landscape for bioabsorbable stents is constantly evolving through continued improvisation on existing technology and emergence of new technology. Large scale randomized trials are still needed with adequate long term follow-up for safety and benefits to have mainstream application in coronary artery disease, bioabsorbable stents are a promising innovation in the field of PCI. We review some of the patents and the data that is emerging on bioabsorbable stents in addition to currently ongoing clinical trials.
Drug-eluting coronary stents – focus on improved patient outcomes
Jaffery, Zehra; Prasad, Amit; Lee, John H; White, Christopher J
2011-01-01
The development of stent has been a major advance in the treatment of obstructive coronary artery disease since the introduction of balloon angioplasty. Subsequently, neointimal hyperplasia within the stent leading to in-stent restenosis emerged as a major obstacle in long-term success of percutaneous coronary intervention. Recent introduction of drug-eluting stents is a major breakthrough to tackle this problem. This review article summarizes stent technology, reviews progress of drug-eluting stents and discusses quality of life, patient satisfaction, and acceptability of percutaneous coronary intervention. PMID:22915977
Danson, Edward J; Ward, Michael
2015-06-01
We present a case of a 58-year-old woman with diabetes mellitus with a history of angina, coronary artery bypass 24 years previously and who underwent retrieval of a fractured coronary buddy wire from the right brachial artery following attempted coronary intervention to a saphenous vein graft via the right radial route. Attempted removal of the guide wire had caused guide catheter-induced dissection of the vein graft in addition to a distal stent edge dissection before fracture in the brachial artery. The fractured end of the buddy wire was found to be in the subintimal space and could only be retrieved by advancing the wire into the subclavian artery by means of wrapping its free portion around the guiding catheter. Its fractured end could then be snared into the guiding catheter but could only be withdrawn from behind the stented segment in the vein graft by means of a trap balloon in the guiding catheter. Successful stenting of a guide catheter-induced dissection and distal stent edge dissection within the vein graft was then performed. This case highlights the hazards of deploying stents over buddy wires and of fractured guide wires in coronary intervention. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Martin, David M; Murphy, Eoin A; Boyle, Fergal J
2014-08-01
In many computational fluid dynamics (CFD) studies of stented vessel haemodynamics, the geometry of the stented vessel is described using non-deformed (NDF) geometrical models. These NDF models neglect complex physical features, such as stent and vessel deformation, which may have a major impact on the haemodynamic environment in stented coronary arteries. In this study, CFD analyses were carried out to simulate pulsatile flow conditions in both NDF and realistically-deformed (RDF) models of three stented coronary arteries. While the NDF models were completely idealised, the RDF models were obtained from nonlinear structural analyses and accounted for both stent and vessel deformation. Following the completion of the CFD analyses, major differences were observed in the time-averaged wall shear stress (TAWSS), time-averaged wall shear stress gradient (TAWSSG) and oscillatory shear index (OSI) distributions predicted on the luminal surface of the artery for the NDF and RDF models. Specifically, the inclusion of stent and vessel deformation in the CFD analyses resulted in a 32%, 30% and 31% increase in the area-weighted mean TAWSS, a 3%, 7% and 16% increase in the area-weighted mean TAWSSG and a 21%, 13% and 21% decrease in the area-weighted mean OSI for Stents A, B and C, respectively. These results suggest that stent and vessel deformation are likely to have a major impact on the haemodynamic environment in stented coronary arteries. In light of this observation, it is recommended that these features are considered in future CFD studies of stented vessel haemodynamics. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Cheng-Hung; Department of Mechanical Engineering, Chang Gung University, Tao-Yuan, Taiwan; Jhong, Guan-Heng
The deployment of metallic stents during percutaneous coronary intervention has become common in the treatment of coronary bifurcation lesions. However, restenosis occurs mostly at the bifurcation area even in present era of drug-eluting stents. To achieve adequate deployment, physicians may unintentionally apply force to the strut of the stents through balloon, guiding catheters, or other devices. This force may deform the struts and impose excessive mechanical stresses on the arterial vessels, resulting in detrimental outcomes. This study investigated the relationship between the distribution of stress in a stent and bifurcation angle using finite element analysis. The unintentionally applied force followingmore » stent implantation was measured using a force sensor that was made in the laboratory. Geometrical information on the coronary arteries of 11 subjects was extracted from contrast-enhanced computed tomography scan data. The numerical results reveal that the application of force by physicians generated significantly higher mechanical stresses in the arterial bifurcation than in the proximal and distal parts of the stent (post hoc P < 0.01). The maximal stress on the vessels was significantly higher at bifurcation angle <70° than at angle ≧70° (P < 0.05). The maximal stress on the vessels was negatively correlated with bifurcation angle (P < 0.01). Stresses at the bifurcation ostium may cause arterial wall injury and restenosis, especially at small bifurcation angles. These finding highlight the effect of force-induced mechanical stress at coronary artery bifurcation stenting, and potential mechanisms of in-stent restenosis, along with their relationship with bifurcation angle.« less
Metabolic Syndrome and Coronary Artery Disease in Ossabaw Compared with Yucatan Swine
Neeb, Zachary P; Edwards, Jason M; Alloosh, Mouhamad; Long, Xin; Mokelke, Eric A; Sturek, Michael
2010-01-01
Metabolic syndrome (MetS), a compilation of associated risk factors, increases the risk of type 2 diabetes and coronary artery disease (CAD, atherosclerosis), which can progress to the point of artery occlusion. Stents are the primary interventional treatment for occlusive CAD, and patients with MetS and hyperinsulinemia have increased restenosis. Because of its thrifty genotype, the Ossabaw pig is a model of MetS. We tested the hypothesis that, when fed high-fat diet, Ossabaw swine develop more features of MetS, greater native CAD, and greater stent-induced CAD than do Yucatan swine. Animals of each breed were divided randomly into 2 groups and fed 2 different calorie-matched diets for 40 wk: control diet (C) and high-fat, high-cholesterol atherogenic diet (H). A bare metal stent was placed in the circumflex artery, and pigs were allowed to recover for 3 wk. Characteristics of MetS, macrovascular and microvascular CAD, in-stent stenosis, and Ca2+ signaling in coronary smooth muscle cells were evaluated. MetS characteristics including, obesity, glucose intolerance, hyperinsulinemia, and elevated arterial pressure were elevated in Ossabaw swine compared to Yucatan swine. Ossabaw swine with MetS had more extensive and diffuse native CAD and in-stent stenosis and impaired coronary blood flow regulation compared with Yucatan. In-stent atherosclerotic lesions in Ossabaw coronary arteries were less fibrous and more cellular. Coronary smooth muscle cells from Ossabaw had impaired Ca2+ efflux and intracellular sequestration versus cells from Yucatan swine. Therefore, Ossabaw swine are a superior model of MetS, subsequent CAD, and cellular Ca2+ signaling defects, whereas Yucatan swine are leaner and relatively resistant to MetS and CAD. PMID:20819380
Nickel-free stainless steel avoids neointima formation following coronary stent implantation
Fujiu, Katsuhito; Manabe, Ichiro; Sasaki, Makoto; Inoue, Motoki; Iwata, Hiroshi; Hasumi, Eriko; Komuro, Issei; Katada, Yasuyuki; Taguchi, Tetsushi; Nagai, Ryozo
2012-01-01
SUS316L stainless steel and cobalt–chromium and platinum–chromium alloys are widely used platforms for coronary stents. These alloys also contain nickel (Ni), which reportedly induces allergic reactions in some subjects and is known to have various cellular effects. The effects of Ni on neointima formation after stent implantation remain unknown, however. We developed coronary stents made of Ni-free high-nitrogen austenitic stainless steel prepared using a N2-gas pressurized electroslag remelting (P-ESR) process. Neointima formation and inflammatory responses following stent implantation in porcine coronary arteries were then compared between the Ni-free and SUS316L stainless steel stents. We found significantly less neointima formation and inflammation in arteries implanted with Ni-free stents, as compared to SUS316L stents. Notably, Ni2+ was eluted into the medium from SUS316L but not from Ni-free stainless steel. Mechanistically, Ni2+ increased levels of hypoxia inducible factor protein-1α (HIF-1α) and its target genes in cultured smooth muscle cells. HIF-1α and their target gene levels were also increased in the vascular wall at SUS316L stent sites but not at Ni-free stent sites. The Ni-free stainless steel coronary stent reduces neointima formation, in part by avoiding activation of inflammatory processes via the Ni-HIF pathway. The Ni-free-stainless steel stent is a promising new coronary stent platform. PMID:27877545
Nickel-free stainless steel avoids neointima formation following coronary stent implantation.
Fujiu, Katsuhito; Manabe, Ichiro; Sasaki, Makoto; Inoue, Motoki; Iwata, Hiroshi; Hasumi, Eriko; Komuro, Issei; Katada, Yasuyuki; Taguchi, Tetsushi; Nagai, Ryozo
2012-12-01
SUS316L stainless steel and cobalt-chromium and platinum-chromium alloys are widely used platforms for coronary stents. These alloys also contain nickel (Ni), which reportedly induces allergic reactions in some subjects and is known to have various cellular effects. The effects of Ni on neointima formation after stent implantation remain unknown, however. We developed coronary stents made of Ni-free high-nitrogen austenitic stainless steel prepared using a N 2 -gas pressurized electroslag remelting (P-ESR) process. Neointima formation and inflammatory responses following stent implantation in porcine coronary arteries were then compared between the Ni-free and SUS316L stainless steel stents. We found significantly less neointima formation and inflammation in arteries implanted with Ni-free stents, as compared to SUS316L stents. Notably, Ni 2+ was eluted into the medium from SUS316L but not from Ni-free stainless steel. Mechanistically, Ni 2+ increased levels of hypoxia inducible factor protein-1 α (HIF-1 α ) and its target genes in cultured smooth muscle cells. HIF-1 α and their target gene levels were also increased in the vascular wall at SUS316L stent sites but not at Ni-free stent sites. The Ni-free stainless steel coronary stent reduces neointima formation, in part by avoiding activation of inflammatory processes via the Ni-HIF pathway. The Ni-free-stainless steel stent is a promising new coronary stent platform.
Friable but treatable: coronary artery dissections in Ehlers-Danlos syndrome.
Zago, Alexandre C; Matte, Bruno S
2013-01-01
Vascular Ehlers-Danlos syndrome is a rare connective tissue disorder associated with arterial dissection or rupture. Percutaneous coronary intervention (PCI) is often critical in patients with this syndrome because their coronary arteries are prone to dissection, enhancing the risk of stent borders dissection when conventional stent deployment pressures are used. Coronary artery bypass graft (CABG) treatment for these patients may also raise concerns because the left internal mammary artery is probably friable. Therefore, coronary artery revascularization in vascular Ehlers-Danlos syndrome either using PCI or CABG is challenging due to the arteries friability. A small number of cases have been published describing the friability of the vessels and associated complications; nevertheless, the optimum treatment remains unclear. We report the case of a 54-year-old woman treated successfully with PCI and CABG in two different acute coronary syndrome episodes, in which specific technical issues related to both procedures were decisive. Copyright © 2011 Wiley Periodicals, Inc.
Optimal treatment of coronary-to-pulmonary artery fistula: surgery, coil or stent graft?
Lipiec, Piotr; Peruga, Jan Zbigniew; Jaszewski, Ryszard; Pawłowski, Witold; Kasprzak, Jarosław
2013-01-01
We report a case of a 57-year-old man with typical angina due to a coronary artery-to-pulmonary artery fistula, which was evident on transthoracic and transesophageal echocardiography with color Doppler flow mapping. The diagnosis was confirmed by coronary angiography. The patient underwent surgical ligation of the fistula. However, repeated transesophageal echocardiography and coronary angiography revealed persistence of the fistula with significant left-to-right shunt. The orifice of the fistula was then obliterated by stent-graft implantation, which was proven successful by angiography and echocardiography. PMID:24570733
Rehman, Azeem A; Turner, Ryan C; Lucke-Wold, Brandon P; Boo, SoHyun
2017-06-01
Intracranial arterial atherosclerosis represents a common cause of stroke. Despite aggressive and optimal medical management, many patients will unfortunately suffer additional cerebrovascular events. The role of endovascular intervention for intracranial atherosclerotic disease continues to be uncertain, particularly in regard to extensive, symptomatic stenosis. We present a case of a 42-year-old man with a complex medical history who presented with recurrent ischemic stroke in the ipsilateral hemisphere despite optimal medical management. Given the length of stenosis and the luminal size of the intracranial cavernous and petrous segments of the internal carotid artery, we used a bare metal coronary stent (4.0 mm × 24 mm). This represents one of the longest stents deployed for intracranial disease reported in the literature. This case illustrates that a long coronary stent might be successfully used to manage extensive intracranial lesions. We also review the efficacy of using 1 very long stent versus multiple overlapping stents, with reference to the coronary angiography literature. Copyright © 2017 Elsevier Inc. All rights reserved.
... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open. ... with a balloon catheter and expands when the balloon is inflated. The stent is then left there to help keep the artery open.
de Almeida, Bruno Lorenção; Kambara, Antonio Massamitsu; Rossi, Fabio Henrique; Moreira, Samuel Martins; de Oliveira, Eduardo Silva Jordao; Linhares Filho, Frederico Augusto de Carvalho; Metzger, Patrick Bastos; Passalacqua, Aldo Zampieri
2014-01-01
Introduction The subclavian steal syndrome is characterized by the vertebral artery flow inversion, due to a stenotic lesion in the origin of the subclavian artery. The Coronary-subclavian Steal Syndrome is a variation of the Subclavian Steal Syndrome and is characterized by inversion of flow in the Internal Thracic artery that has been used as conduct in a myocardial revascularization. Its diagnosis must be suspected in patients with difference in pulse and arterial pressure in the upper limbs, that present with angina pectoris and that have done a myocardial revascularization. Its treatment must be a surgical bypass or a transluminal angioplasty. Objective The objective is to show the left subclavian artery stenting as a safe and effective method to treat the coronary-subclavian steal syndrome. Methods Historical prospective, non-randomized trial, through revision of the hospital records of the patients treated with the stenting of the left subclavian artery, from January 2006 to September 2012. Results In the mentioned period, 4.291 miocardial revascularizations were performed with the use of the left mammary artery, and 16 patients were identified to have the Coronary-subclavian steal syndrome. All of them were submitted to endovascular treatment. The success rate was 100%; two patients experienced minor complications; none of them presented with major complications. Eleven of the 16 patients had ultrassonographic documentation of patent stent for at least one year; two patients lost follow up and other two died. Conclusion The stenting of the left subclavian artery is a good option for the treatment of the Coronary-subclavian Steal Syndrome, with high level of technical and clinical success. PMID:25140474
Experimental Evaluation of a New Single Wire Stainless Steel Fishscale Coronary Stent (Freedomª).
Wang; Verbeken; Mukherjee; Zhou; De Scheerder IK
1996-10-01
Recent randomized clinical trials revealed a significant reduction in angiographic restenosis rates when adjunctive stenting was performed after conventional coronary balloon angioplasty. Current approved coronary stents are however hampered by their rigidity, limiting their trackability in tortuous vessels and furthermore, needing high pressure deployment for optimal vessel apposition. New coronary stents are currently under development, using more biocompatible metal alloys and/or designs which better align to the vessel wall at moderate deployment pressures. We evaluated the safety, efficacy, angiographic and histological effect of a new stainless steel fishscale designed stent (Freedomª, Global Therapeutics, Co., USA) in a porcine coronary and peripheral artery model. Implantation in the right coronary artery was successful in all 20 pigs. Control angiograms at 6 weeks follow-up demonstrated patent vessels and morphologic evaluation showed only a mild fibromuscular neointimal response resulting in an area stenosis of 28.7 +/- 0.18% and a mean neointimal hyperplasia of 0.18 +/- 0.25 mm. Comparison with the Palmaz-Schatzª coronary stent in a porcine peripheral artery model demonstrated similar quantitative angiographic and morphologic vessel analysis results. Also the morphometric data were comparable. Area stenosis: Palmaz-Schatz: 37 +/- 0.24%, Freedom: 21 +/- 0.14%, p = 0.07. Mean neointimal hyperplasia: Palmaz-Schatz: 0.33 +/- 0.24 mm, Freedom: 0.18 +/- 0.08 mm, p = 0.08. CONCLUSION: Freedom coronary stent implantation in a porcine model resulted in a high procedural success without subacute thrombotic occlusions, despite no further anticoagulation nor antiplatelet therapy. Six weeks histopathological and morphometric evaluation demonstrated only a mild fibromuscular neointimal hyperplasia.
Bioresorbable scaffolds in the treatment of coronary artery disease
Zhang, Yaojun; Bourantas, Christos V; Farooq, Vasim; Muramatsu, Takashi; Diletti, Roberto; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Serruys, Patrick W
2013-01-01
Drug-eluting stents have reduced the risk of in-stent restenosis and have broadened the application in percutaneous coronary intervention in coronary artery disease. However, the concept of using a permanent metallic endovascular device to restore the patency of a stenotic artery has inherited pitfalls, namely the presence of a foreign body within the artery causing vascular inflammation, late complications such as restenosis and stent thrombosis, and impeding the restoration of the physiologic function of the stented segment. Bioresorbable scaffolds (BRS) were introduced to potentially overcome these limitations, as they provide temporary scaffolding and then disappear, liberating the treated vessel from its cage. Currently, several BRSs are available, undergoing evaluation either in clinical trials or in preclinical settings. The aim of this review is to present the new developments in BRS technology, describe the mechanisms involved in the resorption process, and discuss the potential future prospects of this innovative therapy. PMID:23662091
Intravascular ultrasound for intracranial angioplasty and stent placement: technical case report.
Wehman, J Christopher; Holmes, David R; Hanel, Ricardo A; Levy, Elad I; Hopkins, L Nelson
2006-10-01
Intravascular ultrasound (IVUS) imaging has been used extensively in coronary artery interventions and has provided invaluable information for the understanding and treatment of coronary arterial disease. We present here the first description, to our knowledge, of IVUS-guided intracranial arterial interventions in the clinical setting. Two patients underwent intracranial angioplasty and stent placement with the assistance of IVUS for the evaluation of their lesions. One patient underwent stenting to treat an occlusive dissection of the left internal carotid artery that occurred during arteriovenous malformation embolization. Another patient underwent angioplasty and stenting for high-grade restenosis of a basilar artery atherosclerotic lesion. Both patients underwent successful revascularization procedures. The patient with the dissection had a small intraventricular and parenchymal hemorrhage documented by computed tomography 4 hours after treatment, but did not develop hydrocephalus or further hemorrhage. Both patients did well clinically and had no permanent neurological deficits. IVUS provided important information in terms of lesion evaluation, stent selection, and stent placement in each case. IVUS of the intracranial circulation may assist the performance of intracranial angioplasty and stenting. It provides useful information that can affect clinical decisions. It may prove to be a valuable tool in clinical use and enhance our understanding of vascular disease of the intracranial circulation, as it has in the coronary circulation.
Heidland, U E; Heintzen, M P; Schoppmann, D; Michel, C J; Strauer, B E
2000-02-25
Balloon angioplasty of a stenosed bypass graft has a much higher risk of recurrent stenosis than dilatation of a stenosed native coronary artery. Intracoronary stent implantation has established itself as the better treatment of native coronary artery stenosis than conventional balloon angioplasty. However, there is still uncertainty whether intracoronary stent implantation in stenosed bypass vessels gives better long-term results than conventional balloon angioplasty. Results were retrospectively analyzed of unrandomized 224 primarily successful interventions--122 balloon dilatations and 102 stent implantations--performed between January 1996 and June 1998 on stenosed coronary bypass grafts, re-examined by coronary angiography an average of 6 months later. All but 11 patients were on combined aspirin and ticlopidine antiplatelet aggregation treatment. There was a significantly lower 6-month restenosis rate (30.4%) after stent implantation than after balloon dilatation (51.6%). The re-intervention rate was also significantly lower after stent implantation. These data suggest that stent implantation of stenosed coronary bypass grafts under cover of platelet-aggregation inhibition with aspirin and ticlopidine provides a lower restenosis and thus higher revascularization rate than conventional balloon dilatation.
Planer, David; Smits, Pieter C; Kereiakes, Dean J; Kedhi, Elvin; Fahy, Martin; Xu, Ke; Serruys, Patrick W; Stone, Gregg W
2011-10-01
This study sought to compare the clinical outcomes of everolimus-eluting stents (EES) versus paclitaxel-eluting stents (PES) in patients with acute coronary syndromes (ACS) and stable coronary artery disease (CAD). Although randomized trials have shown superiority of EES to PES, the safety and efficacy of EES in ACS is unknown. We performed a patient-level pooled analysis from the prospective, randomized SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) II, III, IV, and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials in which 2,381 patients with ACS and 4,404 patients with stable CAD were randomized to EES or to PES. Kaplan-Meier estimates of death, myocardial infarction (MI), ischemia-driven target lesion revascularization, and stent thrombosis were assessed at 2 years and stratified by clinical presentation (ACS vs. stable CAD). At 2 years, patients with ACS compared with stable CAD had higher rates of death (3.2% vs. 2.4%, hazard ratio [HR]: 1.37 [95% confidence interval (CI): 1.02 to 1.85], p = 0.04) and MI (4.9% vs. 3.4%, HR: 1.45 [95% CI: 1.14 to 1.85], p = 0.02). In patients with ACS, EES versus PES reduced the rate of death or MI (6.6% vs. 9.3%, HR: 0.70 [95% CI: 0.52 to 0.94], p = 0.02), stent thrombosis (0.7% vs. 2.9%, HR: 0.25 [95% CI: 0.12 to 0.52], p = 0.0002), and ischemia-driven target lesion revascularization (4.7% vs. 6.2%, HR: 0.69 [95% CI: 0.48 to 0.99], p = 0.04). In patients with stable CAD, EES reduced the rate of death or MI (4.5% vs. 7.1%, HR: 0.62 [95% CI: 0.48 to 0.80], p = 0.0002), stent thrombosis (0.7% vs. 1.8%, HR: 0.34 [95% CI: 0.19 to 0.62], p = 0.0002), and ischemia-driven target lesion revascularization (3.9% vs. 6.9%, HR: 0.55 [95% CI: 0.42 to 0.73], p < 0.0001). Treatment with EES versus PES provides enhanced safety and efficacy regardless of the acuity of the clinical syndrome being treated and appears to mitigate the increased risk of stent thrombosis associated with ACS. (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions [SPIRIT II]; NCT00180310; SPIRIT III: A Clinical Evaluation of the Investigational Device XIENCE V Everolimus Eluting Coronary Stent System [EECSS] in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT III]; NCT00180479; SPIRIT IV Clinical Trial: Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions [SPIRIT IV]; NCT00307047; A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice: the COMPARE Trial [COMPARE]; NCT01016041). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Takase, Susumu; Matoba, Tetsuya; Nakashiro, Soichi; Mukai, Yasushi; Inoue, Shujiro; Oi, Keiji; Higo, Taiki; Katsuki, Shunsuke; Takemoto, Masao; Suematsu, Nobuhiro; Eshima, Kenichi; Miyata, Kenji; Yamamoto, Mitsutaka; Usui, Makoto; Sadamatsu, Kenji; Satoh, Shinji; Kadokami, Toshiaki; Hironaga, Kiyoshi; Ichi, Ikuyo; Todaka, Koji; Kishimoto, Junji; Egashira, Kensuke; Sunagawa, Kenji
2017-02-01
We sought to investigate whether treatment with ezetimibe in combination with statins improves coronary endothelial function in target vessels in coronary artery disease patients after coronary stenting. We conducted a multicenter, prospective, randomized, open-label, blinded-end point trial among 11 cardiovascular treatment centers. From 2011 to 2013, 260 coronary artery disease patients who underwent coronary stenting were randomly allocated to 2 arms (statin monotherapy, S versus ezetimibe [10 mg/d]+statin combinational therapy, E+S). We defined target vessel dysfunction as the primary composite outcome, which comprised target vessel failure during treatment and at the 6- to 8-month follow-up coronary angiography and coronary endothelial dysfunction determined via intracoronary acetylcholine testing performed in cases without target vessel failure at the follow-up coronary angiography. Coadministration of ezetimibe with statins further lowered low-density lipoprotein cholesterol levels (83±23 mg/dL in S versus 67±23 mg/dL in E+S; P<0.0001), with significant decreases in oxidized low-density lipoprotein and oxysterol levels. Among patients without target vessel failure, 46 out of 89 patients (52%) in the S arm and 34 out of 96 patients (35%) in the E+S arm were found to have coronary endothelial dysfunction (P=0.0256), and the incidence of target vessel dysfunction at follow-up was significantly decreased in the E+S arm (69/112 (62%) in S versus 47/109 (43%) in E+S; P=0.0059). A post hoc analysis of post-treatment low-density lipoprotein cholesterol-matched subgroups revealed that the incidence of both target vessel dysfunction and coronary endothelial dysfunction significantly decreased in the E+S arm, with significant reductions in oxysterol levels. The CuVIC trial (Effect of Cholesterol Absorption Inhibitor Usage on Target Vessel Dysfunction after Coronary Stenting) has shown that ezetimibe with statins, compared with statin monotherapy, improves functional prognoses, ameliorating endothelial dysfunction in stented coronary arteries, and was associated with larger decreases in oxysterol levels. © 2016 American Heart Association, Inc.
ALCAPA and massive pulmonary atelectasis: how a stent in the airway can be life-saving.
Serio, Paola; Chiappa, Enrico; Fainardi, Valentina; Favilli, Silvia; Murzi, Bruno; Baggi, Roberto; Arcieri, Luigi; Leone, Roberto; Mirabile, Lorenzo
2014-11-01
Anomalous left coronary artery from pulmonary artery (ALCAPA) is a rare congenital anomaly in which left coronary artery arises from the pulmonary artery resulting in progressive myocardial ischemia and dysfunction of the left ventricle. We report a case of ALCAPA with severe cardiac and respiratory failure and huge heart dilation compressing the left main bronchus and preventing from an effective ventilation. Emergency bronchial stenting allowed to improve left lung atelectasis, reduce pulmonary hypertension, resume anterograde left coronary artery perfusion and stabilize cardiovascular conditions to undertake a successful surgical correction. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Perioperative antiplatelet management in patients with coronary artery stenting.
Tandar, Anwar; Velagapudi, Krishna N; Wilson, Brent D; Boden, William E
2012-04-01
Coronary artery disease is the primary cause of mortality in men and women in the United States. Transcatheter coronary intervention is the mainstay of treatment for patients with acute coronary artery disease presentations and patients with stable disease. Although percutaneous intervention initially only included balloon angioplasty, it now typically involves the placement of intracoronary stents. To overcome the limitations of bare-metal stents, namely in-stent restenosis, stents have been developed that remove pharmaceuticals that reduce neointimal hyperplasia and in-stent restenosis. However, these pharmaceutical agents also delay stent endothelialization, posing a prolonged risk of in situ thrombosis. Placement of an intracoronary stent (eg, bare-metal or drug-eluting stent) requires dual antiplatelet therapy to prevent the potentially life-threatening complication of stent thrombosis. The optimal duration of dual antiplatelet therapy following stent placement is unknown. This article discusses the factors to be considered when deciding when dual antiplatelet therapy can be safely discontinued. Unfortunately, in the hospital setting, this decision to interrupt dual antiplatelet therapy frequently must be made shortly after stent placement because of unanticipated surgical procedures or other unforeseen complications. The decision of when dual antiplatelet therapy can be safely interrupted needs to be individualized for each patient and involves factoring in the type of stent; the location and complexity of the lesion stented; post-stent lesion characteristics; the amount of time since stent placement; and the antiplatelet regimen currently in use, along with its implication for bleeding during the proposed procedure. Having a protocol in place, such as the protocol described in this article, can help guide this decision-making process and avoid confusion and potential error.
Sirolimus- versus paclitaxel-eluting stents in patients with stenosis in a native coronary artery.
Doggrell, Sheila A
2004-06-01
With stenting, restenosis occurs in approximately 25% of patients and the incidence is even higher in patients with diabetes, small coronary vessels and long lesions. The sirolimus-eluting balloon-expandable stent in the treatment of patients with de novo native coronary-artery lesions (SIRIUS) trial, enrolled patients with more challenging conditions, including a higher frequency of diabetes, more complex lesion morphology and longer lesions and showed benefits in all groups. After 240 days, the frequency of stenosis of at least 50% of the luminal diameter was 3.2 and 35.4% in the sirolimus and standard stents groups, respectively. The TAXUS-IV trial was the first large-scale trial on the safety and efficacy of paclitaxel-eluting stents in a broad population of patients and lesions, and established the safety and effectiveness of this agent. After 9 months, there was a mean stenosis of 17% in the paclitaxel group compared to 37% of patients treated with a bare stent. Thus, the local delivery of potent cell cycle inhibitors (sirolimus, paclitaxel) from stents being used for revascularisation dramatically decreases the incidence of restenosis in the populations of patients studied so far and represents a major advancement in the treatment of coronary artery disease.
A Bumpy and Winding but Right Path to Domestic Drug-Eluting Coronary Stents
Cho, Jae Yeong; Ahn, Youngkeun
2013-01-01
Restenosis and stent thrombosis remain major concerns after percutaneous coronary intervention for the treatment of coronary artery disease. The present review was undertaken in order to highlight the various coronary stents that have been investigated in our Heart Research Center, and how far we have come from the first heparin-coated stent first used in the late 1990s. Thereafter, from the abciximab-coated stent to the current gene-delivery stent and other newer agents, our group has applied a range of techniques in this field. However, in groups similar to ours, the restenosis rates of such stents are still high for second-generation drug-eluting stents (DESs). Moreover, our nation imports almost all of these types of stents from other countries. Thus, we need to develop domestic coronary stents. Research into newer DESs are warranted in Korea so as to achieve improved safety and efficacy outcomes. PMID:24255648
Takimura, Celso K; Galon, Micheli Z; Gutierrez, Paulo S; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A
2015-04-01
Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies.
Biomechanical analysis on stent materials used as cardiovascular implants
NASA Astrophysics Data System (ADS)
Kumar, Vasantha; Ramesha, C. M.; Sajjan, Sudheer S.
2018-04-01
Atherosclerosis is the most common cause of death in the world, accounting for 48% of all deaths in the world. Atherosclerosis, also known as coronary artery disease occurs when excess cholesterol attaches itself to the walls of blood vessels. Coronary stent implantation is one of the most important procedures to treating coronary artery disease such atherosclerosis. Due to its efficiency, flexibility and simplicity, the use of coronary stents procedures has increased rapidly. In order to have better output of stent implantation, it is needed to study and analyze the biomechanical behavior of this device before manufacturing and put into use. Biomaterials are commonly used for medical application in cardiovascular stent implantation. A biomaterial is a non-viable material used as medical implant, so it is intended to interact with biological system. In this paper, an explicit dynamic analysis is used for analyzing the biomechanical behavior of cardiovascular stent by using finite element analysis tool, ABAQUS 6.10. Results showed that a best suitable biomaterial for cardiovascular stent implants, which exhibits an outstanding biocompatibility and biomechanical characteristics will be aimed at which will be quite useful to the human beings worldwide.
NASA Astrophysics Data System (ADS)
Wang, Hujun; Liu, Jinghua; Zheng, Xu; Rong, Xiaohui; Zheng, Xuwei; Peng, Hongyu; Silber-Li, Zhanghua; Li, Mujun; Liu, Liyu
2015-06-01
Percutaneous coronary intervention (PCI), especially coronary stent implantation, has been shown to be an effective treatment for coronary artery disease. However, in-stent restenosis is one of the longstanding unsolvable problems following PCI. Although stents implanted inside narrowed vessels recover normal flux of blood flows, they instantaneously change the wall shear stress (WSS) distribution on the vessel surface. Improper stent implantation positions bring high possibilities of restenosis as it enlarges the low WSS regions and subsequently stimulates more epithelial cell outgrowth on vessel walls. To optimize the stent position for lowering the risk of restenosis, we successfully established a digital three-dimensional (3-D) model based on a real clinical coronary artery and analysed the optimal stenting strategies by computational simulation. Via microfabrication and 3-D printing technology, the digital model was also converted into in vitro microfluidic models with 3-D micro channels. Simultaneously, physicians placed real stents inside them; i.e., they performed “virtual surgeries”. The hydrodynamic experimental results showed that the microfluidic models highly inosculated the simulations. Therefore, our study not only demonstrated that the half-cross stenting strategy could maximally reduce restenosis risks but also indicated that 3-D printing combined with clinical image reconstruction is a promising method for future angiocardiopathy research.
Self-expanding stent for spontaneous coronary artery dissection: a rational choice.
Mele, Marco; Langialonga, Tommaso; Maggi, Alessandro; Villella, Massimo; Villella, Alessandro
2016-12-01
: Spontaneous coronary artery dissection (SCAD) is a rare and poorly understood cause of acute coronary syndrome in relatively young patients. Nowadays, the optimal treatment of SCAD is uncertain. A conservative approach seems to be preferable, but in particular conditions, an invasive strategy is necessary. The poor rate of procedural success, the high risk of procedural complications and the uncertain long and mid-term results make the interventional treatment of SCAD a challenge. We report a case of a young male patient presenting with SCAD successfully treated with a sirolimus-eluting self-expanding coronary stent. To our knowledge, the use of self-expanding coronary stent for SCAD has never been described yet and we discuss about the rationale of a possible larger use in clinical practice.
Oxygen Mass Transport in Stented Coronary Arteries.
Murphy, Eoin A; Dunne, Adrian S; Martin, David M; Boyle, Fergal J
2016-02-01
Oxygen deficiency, known as hypoxia, in arterial walls has been linked to increased intimal hyperplasia, which is the main adverse biological process causing in-stent restenosis. Stent implantation has significant effects on the oxygen transport into the arterial wall. Elucidating these effects is critical to optimizing future stent designs. In this study the most advanced oxygen transport model developed to date was assessed in two test cases and used to compare three coronary stent designs. Additionally, the predicted results from four simplified blood oxygen transport models are compared in the two test cases. The advanced model showed good agreement with experimental measurements within the mass-transfer boundary layer and at the luminal surface; however, more work is needed in predicting the oxygen transport within the arterial wall. Simplifying the oxygen transport model within the blood flow produces significant errors in predicting the oxygen transport in arteries. This study can be used as a guide for all future numerical studies in this area and the advanced model could provide a powerful tool in aiding design of stents and other cardiovascular devices.
Borgia, Francesco; Niglio, Tullio; De Luca, Nicola; Di Serafino, Luigi; Esposito, Giovanni; Trimarco, Bruno; Cirillo, Plinio
2018-04-21
Complex coronary artery bifurcation lesions occurred in hard clinical scenarios, such as acute coronary syndromes, may represent a challenge for interventional cardiologists, with not-defined general consensus on treatment. Even if provisional stenting is the most common option used to restore rapidly the coronary branches flow, improvements in industrial technologies and design of new dedicated bifurcation devices might open new modalities of treatment in these complex cases. The Axxess stent (Biosensors Europe SA, Morges, Switzerland) is a self-expanding biolimus-eluting conical V-shape stent, specifically designed to treat "easily" coronary artery bifurcation lesions, with reported favorable long-term clinical results in stable patients compared to a provisional technique. We report for the first time the feasibility to use this device in a case of "true double coronary bifurcation lesion" occurred in the context of acute coronary syndrome. Moreover, we reviewed studies with bifurcation dedicated devices and available cases of "true double bifurcation lesions", underlying advantages/disadvantages of using one device over the others during acute coronary syndrome. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.
2015-11-01
A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.
Galon, Micheli Z.; Gutierrez, Paulo S.; Sojitra, Prakash; Vyas, Ashwin; Doshi, Manish; Lemos, Pedro A.
2015-01-01
Background Permanent polymers in first generation drug-eluting stent (DES) have been imputed to be a possible cause of persistent inflammation, remodeling, malapposition and late stent thrombosis. We aim to describe the in vivo experimental result of a new polymer-free DES eluting sirolimus from stent-plus-balloon (Focus np stent, Envision Scientific) compared with a bare-metal stent (BMS) (Amazonia CroCo, Minvasys) and with a biolimus A9 eluting stent (Biomatrix, Biosensors). Methods In 10 juvenile pigs, 23 coronary stents were implanted in the coronary arteries (8 Amazonia CroCo, 8 Focus np, and 7 Biomatrix). At 28-day follow-up, optical coherence tomography (OCT) and histology were used to evaluate neointimal hyperplasia and healing response. Results According to OCT analysis, Focus np stents had a greater lumen area and less neointimal hyperplasia response than BMS and Biomatrix had. Histomorphometry results showed less neointimal hyperplasia in Focus np than in BMS. Histology showed a higher fibrin deposition in Biomatrix stent compared to Focus np and BMS. Conclusions The new polymer-free DES with sirolimus eluted from stent-plus-balloon demonstrated safety and reduced neointimal proliferation compared with the BMS and Biomatrix stents at 28-day follow-up in this porcine coronary model. This new polymer-free DES is promising and warrants further clinical studies. PMID:25984451
Thuesen, Leif; Galløe, Anders; Thayssen, Per; Rasmussen, Klaus; Kelbæk, Henning; Lassen, Jens Flensted; Hansen, Peter Riis; Pedersen, Knud Erik; Ravkilde, Jan; Helquist, Steffen; Abildgaard, Ulrik; Andersen, Henning Rud; Bøtker, Hans Erik; Kristensen, Steen Dalby; Hjort, Jacob; Krusell, Lars Romer
2005-11-01
To compare deliverability and in-hospital complications in implantation of BxSonic(R), Express(R), and Flexmaster(R) coronary stents in a randomized multicenter trial in five Danish interventional centres. Patients with planned stenting of at least one stenotic lesion in a native coronary artery were included in the study. There were 494 (664) patients (treated lesions) in the BxSonic(R), 499 (657) in the Express(R) and 500 (658) in the Flexmaster(R) groups. The groups were well matched with regard to age, sex, diabetes, smoking, hypercholesterolemia, hypertension, indication for PCI and coronary artery lesion complexity. The study stents were implanted with or without predilatation according to ordinary -clinical practice.Rates of successful stent implantation and in-hospital stent thrombosis, re-intervention, non-fatal myocardial infarction or death. The BxSonic(R), Express(R) and Flexmaster(R) stents were successfully implanted in 92,2%, 89,3% and 91,6% of all lesions (ns). There were no in-hospital deaths and the rates of in-hospital complications were similar in the three stent groups. We found similar deliverability and in-hospital complication rates of the BxSonic(R), Express(R) and Flexmaster(R) stents.
Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan
2015-10-01
Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.
Li, Hu; Choi, Cheol Ung; Oh, Dong Joo
2017-01-01
We report herein the optical coherence tomography (OCT) and stent boost imaging guided bioresorbable vascular scaffold (BVS) implantation for right coronary artery (RCA) chronic total occlusion (CTO) lesion. The gold standard for evaluating BVS expansion after percutaneous coronary intervention is OCT. However, stent boost imaging is a new technique that improves fluoroscopy-based assessments of stent overlapping, and the present case shows clinical usefulness of OCT and stent boost imaging guided ‘overlapping’ BVS implantation via antegrade approach for a typical RCA CTO lesion. PMID:28792157
Chiastra, Claudio; Wu, Wei; Dickerhoff, Benjamin; Aleiou, Ali; Dubini, Gabriele; Otake, Hiromasa; Migliavacca, Francesco; LaDisa, John F
2016-07-26
The optimal stenting technique for coronary artery bifurcations is still debated. With additional advances computational simulations can soon be used to compare stent designs or strategies based on verified structural and hemodynamics results in order to identify the optimal solution for each individual's anatomy. In this study, patient-specific simulations of stent deployment were performed for 2 cases to replicate the complete procedure conducted by interventional cardiologists. Subsequent computational fluid dynamics (CFD) analyses were conducted to quantify hemodynamic quantities linked to restenosis. Patient-specific pre-operative models of coronary bifurcations were reconstructed from CT angiography and optical coherence tomography (OCT). Plaque location and composition were estimated from OCT and assigned to models, and structural simulations were performed in Abaqus. Artery geometries after virtual stent expansion of Xience Prime or Nobori stents created in SolidWorks were compared to post-operative geometry from OCT and CT before being extracted and used for CFD simulations in SimVascular. Inflow boundary conditions based on body surface area, and downstream vascular resistances and capacitances were applied at branches to mimic physiology. Artery geometries obtained after virtual expansion were in good agreement with those reconstructed from patient images. Quantitative comparison of the distance between reconstructed and post-stent geometries revealed a maximum difference in area of 20.4%. Adverse indices of wall shear stress were more pronounced for thicker Nobori stents in both patients. These findings verify structural analyses of stent expansion, introduce a workflow to combine software packages for solid and fluid mechanics analysis, and underscore important stent design features from prior idealized studies. The proposed approach may ultimately be useful in determining an optimal choice of stent and position for each patient. Copyright © 2015 Elsevier Ltd. All rights reserved.
Wilson, Gregory J; Huibregtse, Barbara A; Pennington, Douglas E; Dawkins, Keith D
2012-06-20
This study evaluated vascular compatibility of the novel platinum chromium alloy Element stent platform delivering abluminal everolimus from a poly-lactide-co-glycolide bioabsorbable polymer (SYNERGY stent), currently undergoing clinical trial, compared with the PROMUS (XIENCE V) and bare metal and polymer-only Element stents. Stents (n=161) were implanted one per coronary artery in 72 swine at a stent-to-artery ratio of 1.1:1. Similar numbers of each device group were explanted at each of 30, 90, 180, and 360 days (except no PROMUS (XIENCE V) stent at 360 days) for pathological analysis. There was no stent thrombosis, myocardial infarction, or strut fractures in any group. Vascular response was similar between the SYNERGY and PROMUS (XIENCE V) stents, with no thrombi and complete endothelialisation on both scanning electron microscopy and histology at 30, 90 and 180 days. There were no significant differences for the morphologic parameters of luminal thrombus, endothelial cell coverage, strut tissue coverage, inflammation, internal elastic lamina (IEL) disruption, external elastic lamina (EEL) disruption and medial smooth muscle cell loss across device groups or between time points, but there was mild but greater (p<0.0001) para-strut fibrin at 30 days for both drug-eluting stents (DES) compared with the bare and polymer-only controls; this difference completely dissipated by 90 days. Inflammation was predominantly minimal to mild for all device types. No morphometric parameters, including intimal thickness, stent profile-based area stenosis, and EEL area were significantly different when comparing the SYNERGY stent with the bare metal Element and polymer-only Element control stents at 90, 180 and 360 days. In this non-injured porcine coronary artery model, the bioabsorbable polymer SYNERGY stent demonstrated vascular compatibility equivalent to the PROMUS (XIENCE V) stent and to the bare metal and polymer-only Element stents.
Ishihara, Takayuki; Awata, Masaki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Uematsu, Masaaki; Mano, Toshiaki
2018-01-15
The ultrathin strut biodegradable polymer sirolimus-eluting stent (Orsiro, O-SES) exhibits satisfactory clinical outcomes. However, no report to date has documented the intravascular status of artery repair after O-SES implantation. We examined 5 O-SES placed in 4 patients (age 65 ± 12 years, male 75%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed immediately after percutaneous coronary intervention and 1 year later. Angioscopic images were analyzed to determine the following: (1) dominant grade of neointimal coverage (NIC) over the stent; (2) maximum yellow plaque grade; and (3) existence of thrombus. Yellow plaque grade was evaluated both immediately after stent implantation and at the time of follow-up observation. The other parameters were evaluated at the time of follow-up examination. NIC was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. Yellow plaque severity was graded as: grade 0, white; grade 1, light yellow; grade 2, yellow; and grade 3, intensive yellow. Angioscopic findings at 1 year demonstrated the following: dominant NIC grade 1, grade 2, and grade 3 in 1, 2, and 2 stents, respectively; all stents were covered to some extent; focal thrombus adhesion was observed in only 1 stent. Yellow plaque grade did not change from immediately after stent implantation to follow-up. O-SES demonstrated satisfactory arterial repair 1 year after implantation.
Ductal recanalization and stenting for late presenters with TGA intact ventricular septum
Kothari, Shyam S; Ramakrishnan, Sivasubramanian; Senguttuvan, Nagendra Boopathy; Gupta, Saurabh Kumar; Bisoi, Akshay K
2011-01-01
Introduction: The ideal management strategy for patients presenting late with transposition of great arteries (TGA), intact ventricular septum (IVS), and regressed left ventricle (LV) is not clear. Primary switch, two-stage switch, and Senning operation are the options. Left ventricular retraining prior to arterial switch by ductal stenting may be effective, but the experience is very limited. Methods: Five of six children aged 3–6 months with TGA-IVS and regressed LV underwent recanalization and transcatheter stenting of ductus arteriosus. The ductal stent was removed during arterial switch surgery. Results: The procedure was successful in 5/6 patients. All the patients had totally occluded ductus and needed recanalization with coronary total occlusion hardware. The ductus was dilated and stented with coronary stents. In all the patients, there was significant luminal narrowing despite adequate stent placement and deployment. Two patients needed reintervention for abrupt closure of the stent. Ductal stenting resulted in left ventricular preparedness within 7–14 days. One patient died of progressive sepsis after 14 days of stenting, even though the LV was prepared. Four patients underwent successful uneventful arterial switch surgery. During surgery, it was observed that the mucosal folds of duct were protruding through the struts of the stent in one patient. Conclusions: Ductal stenting is a good alternative strategy for left ventricular retraining in TGA with regressed LV even in patients with occluded ducts. PMID:21976872
Stent implantation influence wall shear stress evolution
NASA Astrophysics Data System (ADS)
Bernad, S. I.; Totorean, A. F.; Bosioc, A. I.; Petre, I.; Bernad, E. S.
2016-06-01
Local hemodynamic factors are known affect the natural history of the restenosis critically after coronary stenting of atherosclerosis. Stent-induced flows disturbance magnitude dependent directly on the strut design. The impact of flow alterations around struts vary as the strut geometrical parameters change. Our results provide data regarding the hemodynamic parameters for the blood flow in both stenosed and stented coronary artery under physiological conditions, namely wall shear stress and pressure drop.
Center for Innovative Minimally Invasive Therapy
1999-11-01
discrete layers within the image. In vivo OCT image of a stent deployed in a swine coronary artery. Shadowing of the metallic stent is seen as areas of...Task 3: Vascular Stent -Grafts Specific Aim 1: Develop novel procedures for the treatment of aneurysms and vascular trauma using percutaneous...applied to coronary anastomoses in chronic studies. One particularly interesting application may be as an external stent to maintain or increase the
Legutko, Jacek; Zasada, Wojciech; Kałuża, Grzegorz L.; Heba, Grzegorz; Rzeszutko, Lukasz; Jakala, Jacek; Dragan, Jacek; Klecha, Artur; Giszterowicz, Dawid; Dobrowolski, Wojciech; Partyka, Łukasz; Jayaraman, Swaminathan; Dudek, Dariusz
2013-01-01
Aims Evaluation of safety and efficacy of ProNOVA XR, a new generation of polymer-free sirolimus eluting stents (SES), utilizing a pharmaceutical excipient for timed release of sirolimus from the XR platform. Methods and results Safety and efficacy of ProNOVA XR coronary stent system was examined in EURONOVA prospective, single arm, multi-center registry of 50 patients with de novo native coronary lesions up to 28 mm in length in arteries between 2.25 and 4 mm. At 6-month, in-stent late lumen loss by QCA was 0.45 ± 0.41 mm and in-stent neointimal volume obstruction in the IVUS sub-study was 14 ± 11%. One-year clinical follow-up revealed a favorable safety profile, with 2% of in-hospital MACE and 6.4% of MACE from hospital discharge up to 12 months (including 1 cardiac death >30 days after stent implantation and 2 TLRs). According to the ARC definition, there was no definite or probable stent thrombosis and 1 possible stent thrombosis (2%) up to 12 months of clinical follow-up. Conclusions In this preliminary evaluation, ProNOVA XR polymer-free sirolimus eluting stent system appeared safe with an early promise of adequate effectiveness in the treatment of de novo coronary lesions in up to 12 months of clinical, angiographic and IVUS follow-up. PMID:23992999
Cardiac surgery or interventional cardiology? Why not both? Let's go hybrid.
Papakonstantinou, Nikolaos A; Baikoussis, Nikolaos G; Dedeilias, Panagiotis; Argiriou, Michalis; Charitos, Christos
2017-01-01
A hybrid strategy, firstly performed in the 1990s, is a combination of tools available only in the catheterization laboratory with those available only in the operating room in order to minimize surgical morbidity and face with any cardiovascular lesion. The continuous evolution of stent technology along with the adoption of minimally invasive surgical approaches, make hybrid approaches an attractive alternative to standard surgical or transcatheter techniques for any given set of cardiovascular lesions. Examples include hybrid coronary revascularization, when an open surgical anastomosis of the left internal mammary artery to the left anterior descending coronary artery is performed along with stent implantation in non-left anterior descending coronary vessels, open heart valve surgery combined with percutaneous coronary interventions to coronary lesions, hybrid aortic arch debranching combined with endovascular grafting for thoracic aortic aneurysms, hybrid endocardial and epicardial atrial fibrillation procedures, and carotid artery stenting along with coronary artery bypass grafting. The cornerstone of success for all of these methods is the productive collaboration between cardiac surgeons and interventional cardiologists. The indications and patient selection of these procedures are still to be defined. However, high-risk patients have already been shown to benefit from hybrid approaches. Copyright © 2016 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
In vitro and in vivo cell-capture strategies using cardiac stent technology - A review.
Ravindranath, Rohan R; Romaschin, Alexander; Thompson, Michael
2016-01-01
Stenosis is a symptom of coronary artery disease (CAD), and is caused by narrowing of arteries in the heart. Over the last several decades, medical implants such as cardiac stents have been developed to counter stenosis. Upon implantation of a stent to open up a restricted artery, narrowing of the artery can reoccur (restenosis), due to an immune response launched by the body towards the stent. Currently, restenosis is a major health concern for patients who have undergone heart surgery for coronary artery disease. Recently, there have been new methods developed to combat restenosis, which have shown potential signs of success. One proposed method is the use of stents to capture cells, thereby reducing immune response. This review will explore the different methods for cell capture both in vitro and in vivo. Biological modifications of the stent will be surveyed, as well as the use of surface science to immobilize biological probes. Immobilization of proteins and nucleotides, as well as use of magnetic field are all methods that will be further discussed. Finally, concluding remarks and future prospects will be presented. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Efficacy of stent angioplasty for symptomatic stenoses of the proximal vertebral artery.
Weber, W; Mayer, T E; Henkes, H; Kis, B; Hamann, G F; Holtmannspoetter, M; Brueckmann, H; Kuehne, D
2005-11-01
To evaluate the safety and efficacy of stent angioplasty in the treatment of symptomatic arteriosclerotic stenoses of the proximal vertebral artery (VA). Thirty-eight symptomatic stenoses of the vertebral origin were treated with flexible balloon-expandable coronary stents. Angiographic and clinical follow-up examinations were obtained in 26 patients at a mean of 11 months. The immediate post-procedural angiographic results showed no residual stenosis in 33 vessels and mild residual stenoses in five vessels. Periprocedurally, there were two asymptomatic technical complications and one TIA. During follow-up re-stenosis could be detected in 10 cases (36%), and vessel occlusions in two patients. Two stents were broken. One of the restenosis caused a TIA within the follow-up period. Flexible balloon-expandable coronary stents proved to be save and effective in preventing vertebrobasilar stroke but were incapable to preserve the proximal vertebral artery lumen. For the VA origine an adequate stent, self-expanding, bioresorbable, or drug-eluting has to be found.
Kapur, Akhil; Hall, Roger J; Malik, Iqbal S; Qureshi, Ayesha C; Butts, Jeremy; de Belder, Mark; Baumbach, Andreas; Angelini, Gianni; de Belder, Adam; Oldroyd, Keith G; Flather, Marcus; Roughton, Michael; Nihoyannopoulos, Petros; Bagger, Jens Peder; Morgan, Kenneth; Beatt, Kevin J
2010-02-02
The purpose of this study was to compare the safety and efficacy of percutaneous coronary intervention (PCI) with stenting against coronary artery bypass grafting (CABG) in patients with diabetes and symptomatic multivessel coronary artery disease. CABG is the established method of revascularization in patients with diabetes and multivessel coronary disease, but with advances in PCI, there is uncertainty whether CABG remains the preferred method of revascularization. The primary outcome was a composite of all-cause mortality, myocardial infarction (MI), and stroke, and the main secondary outcome included the addition of repeat revascularization to the primary outcome events. A total of 510 diabetic patients with multivessel or complex single-vessel coronary disease from 24 centers were randomized to PCI plus stenting (and routine abciximab) or CABG. The primary comparison used a noninferiority method with the upper boundary of the 95% confidence interval (CI) not to exceed 1.3 to declare PCI noninferior. Bare-metal stents were used initially, but a switch to Cypher (sirolimus drug-eluting) stents (Cordis, Johnson & Johnson, Bridgewater, New Jersey) was made when these became available. At 1 year of follow-up, the composite rate of death, MI, and stroke was 10.5% in the CABG group and 13.0% in the PCI group (hazard ratio [HR]: 1.25, 95% CI: 0.75 to 2.09; p=0.39), all-cause mortality rates were 3.2% and 3.2%, and the rates of death, MI, stroke, or repeat revascularization were 11.3% and 19.3% (HR: 1.77, 95% CI: 1.11 to 2.82; p=0.02), respectively. When the patients who underwent CABG were compared with the subset of patients who received drug-eluting stents (69% of patients), the primary outcome rates were 12.4% and 11.6% (HR: 0.93, 95% CI: 0.51 to 1.71; p=0.82), respectively. The CARDia (Coronary Artery Revascularization in Diabetes) trial is the first randomized trial of coronary revascularization in diabetic patients, but the 1-year results did not show that PCI is noninferior to CABG. However, the CARDia trial did show that multivessel PCI is feasible in patients with diabetes, but longer-term follow-up and data from other trials will be needed to provide a more precise comparison of the efficacy of these 2 revascularization strategies. (The Coronary Artery Revascularisation in Diabetes trial; ISRCTN19872154). Copyright (c) 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei
2015-01-01
Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin.
A practical method to rapidly dissolve metallic stents.
Bradshaw, Scott H; Kennedy, Lloyd; Dexter, David F; Veinot, John P
2009-01-01
Metallic stents are commonly used in many clinical applications including peripheral vascular disease intervention, biliary obstruction, endovascular repair of aneurysms, and percutaneous coronary interventions. In the examination of vascular stent placement, it is important to determine if the stent is open or has become obstructed. This is increasingly important in the era of drug-eluting stent usage in coronary arteries. We describe a practical, rapid and cost-effective method to dissolve most metallic stents leaving the vascular and luminal tissues intact. This practical method may replace the laborious and expensive plastic embedding methods currently utilized.
Drug-eluting versus bare-metal coronary stents: where are we now?
Amoroso, Nicholas S; Bangalore, Sripal
2012-11-01
Drug-eluting stents have dramatically reduced the risk of restenosis, but concerns of an increased risk of stent thrombosis have provided uncertainty about their use. Recent studies have continued to show improved procedural and clinical outcomes with drug-eluting stents both in the setting of acute coronary syndromes and stable coronary artery disease. Newer generation drug-eluting stents (especially everolimus-eluting stents) have been shown to be not only efficacious but also safe with reduced risk of stent thrombosis when compared with bare-metal stents, potentially changing the benchmark for stent safety from bare-metal stents to everolimus-eluting stents. While much progress is being made in the development of bioabsorbable polymer stents, nonpolymer stents and bioabsorbable stent technology, it remains to be seen whether these stents will have superior safety and efficacy outcomes compared with the already much improved rates of revascularization and stent thrombosis seen with newer generation stents (everolimus-eluting stents and resolute zotarolimus-eluting stents).
Wisløff, Torbjørn; Atar, Dan; Sønbø Kristiansen, Ivar
2013-01-01
The aim of this study was to estimate the incremental cost effectiveness of replacing bare metal stents (BMS) by drug-eluting stents (DES) when using trial data and registry data. We developed a Markov model (model of cost effectiveness of coronary artery disease) in which 60-year-old patients started by undergoing percutaneous coronary intervention for acute or subacute coronary artery disease. The patients are followed until death or 100 years of age. Data on the occurrence of events (revascularization, acute myocardial infarction, and death) were based on Scandinavian registry data. Separate analyses were conducted with data on effectiveness based on randomized controlled trials and patient registries. On using trial data, it was found that sirolimus-eluting stents (SES) yield 0.003 greater life expectancy and $3300 lower costs than do BMS (dominant strategy). Paclitaxel-eluting stents (PES) yield 0.148 more life years than do SES at additional lifetime costs of $2800 ($21,400 per life year gained). On using registry data, the cost per life year gained was found to be $4900 when replacing BMS with DES. Probabilistic sensitivity analyses, on the other hand, indicate that PES only has a 50%-75% probability of being cost effective, regardless of the type of effectiveness data. DESs are cost effective with current willingness to pay for life year gains. Whether PES or SES is the most effective DES remains uncertain.
Origins of medical innovation: the case of coronary artery stents.
Xu, Shuai; Avorn, Jerry; Kesselheim, Aaron S
2012-11-01
Innovative medical devices make major contributions to patient welfare, and coronary stents have been among the most important device developments of recent decades. However, the origins of such breakthrough medical technologies remain poorly understood. Using a comprehensive database of patents, we identified all individuals and institutions that developed intellectual property related to stent technology early in its development process. The patents were categorized and described using a predetermined qualitative coding strategy. We found 245 granted patents related to bare metal coronary artery stents from 1984 (when the first patent issued in this field) to 1994 (after the first stents were approved). Each year showed an increase in the number of patent filings: from 1 in 1984 to 97 in 1994. The largest fraction of patents was issued to private entities (44.9% of the total). Public companies, individual inventors, and nonprofit institutions represented 31.4%, 18.0%, and 5.7%, respectively. The top 10 most-cited patents in the field were dominated by 2 private entities, Expandable Grafts Partnership and Cook Inc, organizations created by or dependent on the work of independent academic physician-inventors. Coronary artery stent technology first arose from individual physician-inventors within academic medical centers and their associated private companies. After these initial innovations were in place, the field became dominated by large public companies. This history suggests that policies aimed at encouraging transformative medical device development would have their greatest effect if focused on individual inventors and scientists performing the early stages of technology development.
Geyer, Lucas L; Glenn, G Russell; De Cecco, Carlo Nicola; Van Horn, Mark; Canstein, Christian; Silverman, Justin R; Krazinski, Aleksander W; Kemper, Jenny M; Bucher, Andreas; Ebersberger, Ullrich; Costello, Philip; Bamberg, Fabian; Schoepf, U Joseph
2015-09-01
To use suitable objective methods of analysis to assess the influence of the combination of an integrated-circuit computed tomographic (CT) detector and iterative reconstruction (IR) algorithms on the visualization of small (≤3-mm) coronary artery stents. By using a moving heart phantom, 18 data sets obtained from three coronary artery stents with small diameters were investigated. A second-generation dual-source CT system equipped with an integrated-circuit detector was used. Images were reconstructed with filtered back-projection (FBP) and IR at a section thickness of 0.75 mm (FBP75 and IR75, respectively) and IR at a section thickness of 0.50 mm (IR50). Multirow intensity profiles in Hounsfield units were modeled by using a sum-of-Gaussians fit to analyze in-plane image characteristics. Out-of-plane image characteristics were analyzed with z upslope of multicolumn intensity profiles in Hounsfield units. Statistical analysis was conducted with one-way analysis of variance and the Student t test. Independent of stent diameter and heart rate, IR75 resulted in significantly increased xy sharpness, signal-to-noise ratio, and contrast-to-noise ratio, as well as decreased blurring and noise compared with FBP75 (eg, 2.25-mm stent, 0 beats per minute; xy sharpness, 278.2 vs 252.3; signal-to-noise ratio, 46.6 vs 33.5; contrast-to-noise ratio, 26.0 vs 16.8; blurring, 1.4 vs 1.5; noise, 15.4 vs 21.2; all P < .001). In the z direction, the upslopes were substantially higher in the IR50 reconstructions (2.25-mm stent: IR50, 94.0; IR75, 53.1; and FBP75, 48.1; P < .001). The implementation of an integrated-circuit CT detector provides substantially sharper out-of-plane resolution of coronary artery stents at 0.5-mm section thickness, while the use of iterative image reconstruction mostly improves in-plane stent visualization.
Bartorelli, Antonio L; Serruys, Patrick W; Miquel-Hébert, Karine; Yu, Shui; Pierson, Wes; Stone, Gregg W
2010-07-01
To evaluate the safety and efficacy of the XIENCE V everolimus-eluting stent compared to the TAXUS paclitaxel-eluting stent in small vessels. The XIENCE V everolimus-eluting stent (EES) has been shown to improve angiographic and clinical outcomes after percutaneous myocardial revascularization, but its performance in small coronary arteries has not been investigated. In this pooled analysis, we studied a cohort of 541 patients with small coronary vessels (reference diameter <2.765 mm) by using patient and lesion level data from the SPIRIT II and SPIRIT III studies. TAXUS Express (73% of lesions) and TAXUS Liberté (27% of lesions) paclitaxel-eluting stents (PES) were used as controls in SPIRIT II. In SPIRIT III, Taxus Express(2) PES was the control. Mean angiographic in-stent and in-segment late loss was significantly less in the EES group compared with the PES group, (0.15 +/- 0.37 mm vs. 0.30 +/- 0.44 mm; P = 0.011 for in-stent; 0.10 +/- 0.38 mm vs. 0.21 +/- 0.34 mm; P = 0.034 for in-segment). EES also resulted in a significant reduction in composite major adverse cardiac events at 1 year (19/366 [5.2%] vs. 17/159 [10.7%]; P = 0.037), due to fewer non-Q-wave myocardial infarctions and target lesion revascularizations. At 1 year, the rate of non-Q-wave myocardial infarction was significantly lower in the EES group compared with that of the PES group (6/366 [1.6%] vs. 8/159 [5.0%]; P = 0.037). In patients with small vessel coronary arteries, the XIENCE V EES was superior to the TAXUS PES. (c) 2010 Wiley-Liss, Inc.
Mischke, Karl; Knackstedt, Christian; Marx, Nikolaus
2012-01-01
Anticoagulation represents the mainstay of therapy for most patients with atrial fibrillation. Patients on oral anticoagulation often require concomitant antiplatelet therapy, mostly because of coronary artery disease. After coronary stent implantation, dual antiplatelet therapy is necessary. However, the combination of oral anticoagulation and antiplatelet therapy increases the bleeding risk. Risk scores such as the CHA2DS2-Vasc score and the HAS-BLED score help to identify both bleeding and stroke risk in individual patients. The guidelines of the European Society of Cardiology provide a rather detailed recommendation for patients on oral anticoagulation after coronary stent implantation. However, robust evidence is lacking for some of the recommendations, and especially for new oral anticoagulants and new antiplatelets few or no data are available. This review addresses some of the critical points of the guidelines and discusses potential advantages of new anticoagulants in patients with atrial fibrillation after stent implantation. PMID:22577538
Kuno, Toshiki; Fujisawa, Taishi; Yamazaki, Hiroyuki; Motoda, Hiroyuki; Kodaira, Masaki; Numasawa, Yohei
2015-01-01
Objective: Percutaneous coronary intervention for anomalous right coronary artery (RCA) originating from the left coronary cusp is challenging because of our current inability to coaxially engage the guiding catheter. Methods: We report a case of an 88-year-old woman with non-ST segment elevation myocardial infarction, with an anomalous RCA origin. Using either the Judkins-Left catheter or Amplatz-Left catheter was difficult because of RCA ostium tortuosity. Thus, we used steam to deform the Judkins-Left catheter, but back-up support was insufficient to deliver the stent. Results: We used GuideLiner®, a novel pediatric catheter with rapid exchange/monorail systems, to enhance back-up support. Conclusions: We were able to successfully stent with both the deformed Judkins-Left guiding catheter and GuideLiner® for an anomalous RCA origin. PMID:27489700
Teijink, J A W; van Herwaarden, J A; van den Berg, J C; Overtoom, T C; Moll, F L
2004-06-01
In the treatment of coronary artery disease, peripheral loss of a coronary stent is an unusual complication. We present the case of a patient who suggested that his right leg claudication was caused by a slipped coronary stent 2 years previously. The patient was convinced about this unusual finding based on an airport security check. Examination proved him to be right. However, the ability to detect an object using eddy currents is dependent on the object's permeability and its conductivity. Ferrous (iron) content is not the critical factor. Modern implant materials and processing techniques result in implants that are difficult to magnetize i.e. their permeability is very low. In addition their conductivity is very low. This enables modern implants to escape detection at airports. For this reason the event at the airport, as described by our patient, is considered coincidental.
Van Mieghem, Carlos A G; Cademartiri, Filippo; Mollet, Nico R; Malagutti, Patrizia; Valgimigli, Marco; Meijboom, Willem B; Pugliese, Francesca; McFadden, Eugene P; Ligthart, Jurgen; Runza, Giuseppe; Bruining, Nico; Smits, Pieter C; Regar, Evelyn; van der Giessen, Willem J; Sianos, Georgios; van Domburg, Ron; de Jaegere, Peter; Krestin, Gabriel P; Serruys, Patrick W; de Feyter, Pim J
2006-08-15
Surveillance conventional coronary angiography (CCA) is recommended 2 to 6 months after stent-supported left main coronary artery (LMCA) percutaneous coronary intervention due to the unpredictable occurrence of in-stent restenosis (ISR), with its attendant risks. Multislice computed tomography (MSCT) is a promising technique for noninvasive coronary evaluation. We evaluated the diagnostic performance of high-resolution MSCT to detect ISR after stenting of the LMCA. Seventy-four patients were prospectively identified from a consecutive patient population scheduled for follow-up CCA after LMCA stenting and underwent MSCT before CCA. Until August 2004, a 16-slice scanner was used (n = 27), but we switched to the 64-slice scanner after that period (n = 43). Patients with initial heart rates > 65 bpm received beta-blockers, which resulted in a mean periscan heart rate of 57 +/- 7 bpm. Among patients with technically adequate scans (n = 70), MSCT correctly identified all patients with ISR (10 of 70) but misclassified 5 patients without ISR (false-positives). Overall, the accuracy of MSCT for detection of angiographic ISR was 93%. The sensitivity, specificity, and positive and negative predictive values were 100%, 91%, 67%, and 100%, respectively. When analysis was restricted to patients with stenting of the LMCA with or without extension into a single major side branch, accuracy was 98%. When both branches of the LMCA bifurcation were stented, accuracy was 83%. For the assessment of stent diameter and area, MSCT showed good correlation with intravascular ultrasound (r = 0.78 and 0.73, respectively). An intravascular ultrasound threshold value > or = 1 mm was identified to reliably detect in-stent neointima hyperplasia with MSCT. Current MSCT technology, in combination with optimal heart rate control, allows reliable noninvasive evaluation of selected patients after LMCA stenting. MSCT is safe to exclude left main ISR and may therefore be an acceptable first-line alternative to CCA.
[Two cases of acute coronary syndrome after intake of Clavis Panax].
Atar, Aslı İnci; Er, Okan; Güven, Abdullah; Eryonucu, Beyhan
2012-04-01
Atherosclerotic cardiovascular disease is an epidemic in today's world. It is one of the most common causes of hospitalization and death. Therefore, remedies to control or heal the disease are continuously sought. In addition to scientifically researched therapies, patients frequently utilize alternative medicine. However, effective and toxic doses, metabolisms, and drug interactions of the herbs and herbal nutrition supplements are largely unknown. Herein, we present two cases with acute coronary syndrome. The first case was admitted with a diagnosis of acute inferior myocardial infaction (MI) and a stent was implanted to the occluded right coronary artery (RCA). There was a 50% stenosis in his left anterior descending artery (LAD). He was admitted with a diagnosis of non-ST elevation MI (NSTEMI) 6 months later. In the coronary angiogram, there was stent restenosis in RCA, the lesion in LAD had become thrombotic and progressed to a stenosis of 90%. He was referred to surgical revascularization. The second case was admitted for acute inferior MI and a stent was implanted to the occluded circumflex artery. Two months later, he was hospitalized for NSTEMI. Progression of coronary plaques to stenosis and stent restenosis was detected and he was referred to surgical revascularization. Both patients used the product sold as Clavis Panax, which contains panax ginseng, tribulus terrestris, and oat, after their first coronary intervention. Intake of a mixture of plant extracts may have serious consequences in humans as drug interactions and side effects are unknown.
Anomalous origin of right coronary artery from left coronary sinus.
Hamzeh, Gadah; Crespo, Alex; Estarán, Rafael; Rodríguez, Miguel A; Voces, Roberto; Aramendi, José I
2008-08-01
Anomalous aortic origin of the coronary arteries is uncommon but clinically significant. Manifestations vary from asymptomatic patients to those who present with angina pectoris, myocardial infarction, heart failure, syncope, arrhythmias, and sudden death. We describe 4 patients, aged 34 to 59 years, who were diagnosed with right coronary artery arising from the left sinus of Valsalva, confirmed by coronary angiography, which was surgically repaired. Three patients presented dyspnea and angina, and one with acute myocardial infarction. At operation, the right coronary artery was dissected at the take-off from the intramural course, and reimplanted into the right sinus of Valsalva. There was no mortality. One patient had associated coronary artery disease that required stent placement postoperatively. This reimplantation technique provides a good physiological and anatomical repair, eliminates a slit-like ostium, avoids compression of the coronary artery between the aorta and the pulmonary artery, and gives superior results to coronary artery bypass grafting or the unroofing technique.
Grube, Eberhard; Chevalier, Bernard; Smits, Peter; Džavík, Vladimir; Patel, Tejas M; Mullasari, Ajit S; Wöhrle, Jochen; Stuteville, Marrianne; Dorange, Cécile; Kaul, Upendra
2011-02-01
The SPIRIT V (A Clinical Evaluation of the XIENCE V Everolimus-Eluting Coronary Stent System in the Treatment of Patients With De Novo Coronary Artery Lesions) study is a post-market surveillance experience of the XIENCE V (Abbott Vascular, Santa Clara, California) everolimus-eluting stent (EES) in patients with higher-risk coronary anatomy. Previous pre-approval studies have shown the safety and efficacy of EES in highly selected groups of patients. The SPIRIT V trial is a prospective, open label, single arm, multicenter study. Two thousand seven hundred patients with multiple de novo coronary artery lesions suitable for treatment with a planned maximum of 4 EES were enrolled at 93 centers in Europe, Asia Pacific, Canada, and South Africa. Lesions had a reference vessel diameter between 2.25 and 4.0 mm and a length of ≤ 28 mm by visual estimation. An independent clinical events committee adjudicated all end point-related events. The primary end point was the composite rate of all death, myocardial infarction (MI), and target vessel revascularization at 30 days. Secondary end points included stent thrombosis and acute success (clinical device and procedure success). At 30 days, the primary composite end point of all death, MI, and target vessel revascularization was 2.7%. At 1 year, rates of cardiac death, overall MI, and target lesion revascularization were 1.1%, 3.5%, and 1.8%, respectively. The cumulative rate of definite and probable stent thrombosis was low at 0.66% at 1 year. Use of EES in patients with multiple, complex de novo lesions yielded 1-year major adverse cardiac events, stent thrombosis, and target lesion revascularization rates that are comparable to those of the more controlled SPIRIT II and SPIRIT III trials-which included patients with restricted inclusion/exclusion criteria-and other all-comer population, physician-initiated studies like the X-SEARCH (Xience Stent Evaluated At Rotterdam Cardiology Hospital) and COMPARE (A Randomized Controlled Trial of Everolimus-eluting Stents and Paclitaxel-eluting Stents for Coronary Revascularization in Daily Practice) trials. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Kandzari, David E; Smits, Pieter C; Love, Michael P; Ben-Yehuda, Ori; Banai, Shmuel; Robinson, Simon D; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y; Balcells, Mercedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R; Leon, Martin B; Stone, Gregg W
2017-10-03
The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, P noninferiority =0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P =0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm ( P noninferiority =0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively ( P noninferiority =0.01). In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01995487. © 2017 American Heart Association, Inc.
Hou, Dongming; Huibregtse, Barbara A; Eppihimer, Michael; Stoffregen, William; Kocur, Gordon; Hitzman, Cory; Stejskal, Elizabeth; Heil, John; Dawkins, Keith D
2016-08-20
Our aim was to evaluate arterial responses to paclitaxel and a novel fluorocopolymer-coated nitinol low-dose paclitaxel-eluting stent (FP-PES). Human smooth muscle cell (SMC) migration was assessed after exposure to paclitaxel in vitro. For pharmacokinetics and vascular response, FP-PES or bare metal stents (BMS) were implanted in porcine iliofemoral arteries. Paclitaxel significantly inhibited human coronary and femoral artery SMC migration at doses as low as 1 pM. Inhibition was significantly greater for femoral compared with coronary artery SMCs from 1 pM to 1 μM. Pharmacokinetics showed consistent paclitaxel release from FP-PES over the study duration. The peak arterial wall paclitaxel level was 3.7 ng/mg at 10 days, with levels decreasing to 50% of peak at 60 days and 10% at 180 days. Paclitaxel was not detected in blood or remote organs. Arteriogram and histomorphometry analyses showed FP-PES significantly inhibits neointimal proliferation versus BMS at 30 and 90 days. Re-endothelialisation scores were not different between groups. Paclitaxel affected femoral artery SMC migration at lower concentrations and to a greater degree than it did coronary artery SMCs. The novel FP-PES used in this preclinical study demonstrated a vascular healing response similar to BMS, while significantly inhibiting neointimal formation up to 90 days.
Computer Simulations of Coronary Blood Flow Through a Constriction
2014-03-01
interventional procedures (e.g., stent deployment). Building off previous models that have been partially validated with experimental data, this thesis... stent deployment). Building off previous models that have been partially validated with experimental data, this thesis continues to develop the...the artery and increase blood flow. Generally a stent , or a mesh wire tube, is permanently inserted in order to scaffold open the artery wall
Lee, Cheol Whan; Ahn, Jung-Min; Cavalcante, Rafael; Sotomi, Yohei; Onuma, Yoshinobu; Suwannasom, Pannipa; Tenekecioglu, Erhan; Yun, Sung-Cheol; Park, Duk-Woo; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Park, Seong-Wook; Serruys, Patrick W; Park, Seung-Jung
2016-12-26
The authors undertook a patient-level meta-analysis to compare long-term outcomes after coronary artery bypass grafting (CABG) versus percutaneous coronary intervention (PCI) with drug-eluting stents (DES) in 3,280 patients with left main or multivessel coronary artery disease (CAD). The relative efficacy and safety of CABG versus PCI with DES for left main or multivessel CAD remain controversial. Data were pooled from the BEST (Randomized Comparison of Coronary Artery Bypass Surgery and Everolimus Eluting Stent Implantation in the Treatment of Patients With Multivessel Coronary Artery Disease), PRECOMBAT (Premier of Randomized Comparison of Bypass Surgery vs. Angioplasty Using Sirolimus-Eluting Stent in Patients With Left Main Coronary Artery Disease), and SYNTAX (Synergy Between PCI With Taxus and Cardiac Surgery) trials. The primary outcome was a composite of all-cause death, myocardial infarction, or stroke. The median follow-up was 60 months, and follow-up was completed for 96.2% of patients. The rate of primary outcome was significantly lower with CABG than with PCI (13.0% vs. 16.0%; hazard ratio [HR]: 0.83; 95% confidence interval [CI]: 0.69 to 1.00; p = 0.046). The difference was mainly driven by reduction in myocardial infarction (HR: 0.46; 95% CI: 0.33 to 0.64; p < 0.001). There was significant interaction between treatment effect and types of CAD, showing CABG to be superior compared with PCI with DES in patients with multivessel CAD (p = 0.001), but no between-group difference in those with left main CAD (p = 0.427). The rates for all-cause death and stroke were similar between the 2 groups. By contrast, the need for repeat revascularization was significantly lower in the CABG group compared with the PCI group. CABG, as compared with PCI with DES, reduced long-term rates of the composite of all-cause death, myocardial infarction, or stroke in patients with left main or multivessel CAD. The advantage of CABG over PCI with DES was particularly pronounced in those with multivessel CAD. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A rare complication: Undeflatable balloon of the stent
Şatiroğlu, Ömer; Erdoğan, Turan; Durakoğlugil, Murtaza Emre; Uğurlu, Yavuz
2013-01-01
Percutaneous coronary intervention is an important modality in the treatment of coronary artery disease. These procedures are usually completed successfully, but occasionally serious complications are encountered. In this paper, we present the case of an undeflatable stent balloon, which is an extremely rare complication that has not been described in the literature. PMID:24265889
Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo
2017-10-01
The monorail Guidezilla guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others.The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications.The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access.In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery.
Ma, Jianying; Hou, Lei; Qian, Juying; Ge, Lei; Zhang, Feng; Chang, Shufu; Xu, Rende; Qin, Qing; Ge, Junbo
2017-01-01
Abstract The monorail GuidezillaTM guide extension catheter was designed to provide additional backup and facilitate device delivery in percutaneous coronary intervention (PCI) for complex coronary anatomy such as chronic total occlusion (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries, among others. The present retrospective, single-center study included 188 consecutive patients who underwent PCI using the Guidezilla catheter from March 2015 to August 2016. Study outcomes were rates of target lesion crossing success, procedural success, and complications. The Guidezilla catheter was used most commonly in PCI of CTOs (45%) and heavy proximal calcification (37%), followed by tortuosity (10%), previously deployed proximal stents (4%), and coronary artery anomaly (4%). The right coronary artery (48%) was most commonly intervened followed by the left ascending (35%) and left circumflex (17%) arteries. Rates of target lesion crossing success and procedural success were both 99%, with one device-related periprocedural complication, namely proximal vessel dissection secondary to deep insertion which was successfully treated with stent implantation. Ninety percent of PCI were performed and completed successfully by radial access. In a single center with experienced operators, the use of the Guidezilla guide extension catheter in PCI of complex coronary anatomy performed mostly via radial artery access appeared safe and efficacious, and greatly facilitated device delivery. PMID:28984768
Kappetein, Arie Pieter; Serruys, Patrick W; Sabik, Joseph F; Leon, Martin B; Taggart, David P; Morice, Marie-Claude; Gersh, Bernard J; Pocock, Stuart J; Cohen, David J; Wallentin, Lars; Ben-Yehuda, Ori; van Es, Gerrit-Anne; Simonton, Charles A; Stone, Gregg W
2016-09-18
Coronary artery bypass graft (CABG) surgery is the standard of care for revascularisation of patients with left main coronary artery disease (LMCAD). Recent studies have suggested that percutaneous coronary intervention (PCI) with drug-eluting stents (DES) may provide comparable outcomes in selected patients with LMCAD without extensive CAD. We therefore designed a trial to investigate whether PCI with XIENCE cobalt-chromium everolimus-eluting stents (CoCr-EES) would result in non-inferior or superior clinical outcomes to CABG in selected patients with LMCAD. The Evaluation of XIENCE versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) trial is a prospective, open-label, multicentre, international study of 1,900 randomised subjects. Patients with significant LMCAD with a SYNTAX score ≤32 and local Heart Team consensus that the subject is appropriate for revascularisation by both PCI and CABG are consented and randomised 1:1 to undergo PCI using CoCr-EES or CABG. All patients undergo follow-up for five years. The primary endpoint is the three-year composite rate of death, stroke or myocardial infarction, assessed at a median follow-up of at least three years (with at least two-year follow-up in all patients), powered for sequential non-inferiority and superiority testing. The EXCEL study will define the contemporary roles of CABG and PCI using XIENCE CoCr-EES in patients with LMCAD disease with low and intermediate SYNTAX scores.
Scheller, Bruno; Speck, Ulrich; Romeike, Bernd; Schmitt, Alexander; Sovak, Milos; Böhm, Michael; Stoll, Hans Peter
2003-08-01
Lipophilic taxanes can be dissolved in contrast media at significantly higher concentration than in saline. As contrast media have occasionally been observed to delineate the contour of coronary arteries for some seconds they may serve as a matrix for an antiproliferative drug aimed at preventing restenosis. The aim of this study was to test a novel taxane-contrast agent formulation for this new approach in the setting of coronary stenting. In cell culture experiments (bovine vascular smooth muscle cells), 60-min incubation with contrast agent-taxane formulations (iopromide-paclitaxel, iopromide-protaxel) induced a significant, concentration-dependent inhibition of vascular smooth muscle cell (VSMC) proliferation over 12 days. Shorter incubation times of 10 and 3 min showed the same efficacy. For in vivo investigation, 16 stents were implanted into the coronary arteries of eight pigs using a 1.3 to 1 overstretch ratio. A control group received iopromide 370 alone while the treatment group was injected with a iopromide-protaxel formulation at a dose of 74 micromol/l, which is far below protaxel levels inducing systemic toxicity. Quantitative angiography and histomorphometry of the stented arteries asserted statistic equality of the baseline parameters between the control and treatment groups. After 28 days, the treatment group showed a marked reduction of the parameters characterizing in-stent restenosis, especially a 34% reduction of the neointimal area. First evidence is provided that using a contrast agent as solvent for a taxane constitutes a new drug delivery mechanism able to inhibit in-stent restenosis in the porcine restenosis model.
Jeyakumaran, Balakumaran; Raj, Ajay; Pandit, Bhagya Narayan; Kumar, Tarun; Deora, Surender
2015-12-01
Iatrogenic left main coronary artery (LMCA) dissection is a rare complication and may have devastating consequences if not immediately intervened. The management includes urgent revascularization mostly with percutaneous coronary intervention (PCI) with bail-out stenting and rarely requires coronary artery bypass graft (CABG) surgery. In clinically and hemodynamically stable patients, a conservative approach may be preferred. Here, we present a rare case of iatrogenic retrograde LMCA dissection due to pin-hole rupture of angioplasty balloon that was managed conservatively.
Helmy, Tarek A; Sanchez, Carlos E; Bailey, Steven R
2016-03-01
Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries. © 2015 Wiley Periodicals, Inc.
Werner, Gerald S; Ahmed, Waqar H
2017-09-01
Covered stents are indicated for coronary perforations, but they may seal off major side branches in that process. We report the successful sealing of an ostial left main perforation, induced by a guide catheter in the course of a retrograde approach to treat a chronic total occlusion (CTO) of the right coronary artery (RCA) in a 76year old woman with prior CABG. The implanted Papyrus covered stent, however, overlapped the left main bifurcation and occluded the non-grafted circumflex artery (CX) resulting in acute ischemia. Through a double lumen catheter advanced over the wire located in the left anterior descending coronary artery (LAD) territory, a stiff recanalization wire could be advanced from the side-port to penetrate the stent membrane towards the CX. This was successfully achieved, and after subsequent dilatation, a drug-eluting stent was implanted in Culotte-fashion from the CX to the left main with subsequent kissing-balloon dilatation. The clinical symptoms subsided immediately, and the RCA was finally recanalized in antegrade parallel wire technique. No periprocedural infarct was observed during 48h of follow-up before discharge. At clinical follow-up of 6months the patient is symptom-free. Copyright © 2017 Elsevier Inc. All rights reserved.
Salarifar, Mojtaba; Kassaian, Seyed Ebrahim; Alidoosti, Mohammad; Haji-Zeinali, Ali Mohammad; Poorhoseini, Hamid Reza; Nematipour, Ebrahim; Amirzadegan, Alireza; Saroukhani, Sepideh
2011-01-01
For all the wealth of research comparing the efficacy of the different types of the drug-eluting stent (DES) such as sirolimus-, paclitaxel-, and zotarolimus-eluting stents, there is still a dearth of data on the different brands of each DES type. We aimed to investigate the one-year clinical outcomes, including major adverse cardiac events (MACE), of the use of the ultra long Apollo paclitaxel-eluting stent in patients with long atherosclerotic coronary artery lesions. According to a retrospective review of the Tehran Heart Center Registry of Interventional Cardiology, a single-center nonrandomized computerized data registry in which all adult patients who undergo single or multi-vessel percutaneous coronary intervention (PCI) are enrolled without any specific exclusion criteria, the mixed use of long Apollo paclitaxel-eluting stents and other types of the DES as well as myocardial infarction within forty-eight hours prior to the procedure was excluded. In total, 122 patients were enrolled in the study, and their baseline clinical, angiographic, and procedural characteristics were obtained. In addition, the patients' follow-up data and, most importantly, MACE during a one-year period after intervention were recorded. The mean follow-up duration was 14.1 ± 3.8 months. The one-year clinical follow-up data were obtained in 95.9 % of all the patients. The incidence of MACE was 5.7% during the entire study period. There was 1 death, which occurred during the initial days after PCI. The incidence of non-fatal myocardial infarction was 2.5% (3 cases), including one patient who underwent target vessel revascularization seven months later. Also, 3 patients with single-vessel disease and in-stent restenosis underwent coronary artery bypass grafting between five to ten months later. Our results showed that the Apollo paclitaxel-eluting stent might be regarded as a safe and effective treatment for long coronary lesions.
Paradies, Valeria; Ben-Yehuda, Ori; Jonas, Michael; Banai, Shmuel; Iñiguez, Andres; Perlman, Gidon Y; Kandzari, David E; Stone, Gregg W; Smits, Pieter C
2018-05-20
The aim of this study was to evaluate the efficacy and safety of the BioNIR stent compared with the Resolute Integrity stent for the treatment of coronary artery disease. This first-in-human, multicentre, single-blind randomised non-inferiority trial was performed in Europe and Israel. Patients with stable coronary artery disease or acute coronary syndromes were randomly assigned to treatment with BioNIR or Resolute Integrity stents in a 2:1 fashion. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Three hundred and two patients were randomised, of whom 261 (86.0%) underwent six-month angiographic follow-up. The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of in-stent LLL at six months (0.04±0.30 mm vs. 0.03±0.31 mm, respectively, pnoninferiority<0.0001). At 12-month follow-up, target lesion failure occurred in 3.4% in the BioNIR group and 5.9% in the Resolute Integrity group (p=0.22). Rates of MACE were similar between the BioNIR and Resolute Integrity groups (4.3% vs. 5.9%, respectively, p=0.45). The BioNIR stent was non-inferior to the Resolute Integrity stent for the primary endpoint of angiographic in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.
Kodama, Atsuko; Kurita, Tairo; Kato, Osamu; Suzuki, Takahiko
2016-11-01
Aneurysmal degeneration of a saphenous vein graft (SVG) is a rare, but potentially fatal complication of coronary artery bypass graft (CABG) surgery. In this case report, a patient that had undergone prior CABG surgery and bare metal stent (BMS) implantation at the site of a stenotic SVG lesion presented at our hospital with chest pain, and an SVG aneurysm was detected at the previous BMS implantation site. In addition, the implanted BMS was fractured and floating in the SVG aneurysm. The SVG aneurysm was successfully occluded by percutaneous intervention, using a combination of distal covered stent deployment at the site of the anastomosis between the native coronary artery and the SVG and proximal coil embolization of the aneurysm.
[Loss of capture by myocardial ischemia: A case report].
Sonou, A; Adjagba, P M; Hounkponou, M; Codjo, L; Houéhanou-Sonou, C; Assani, S; Yessoufou, T; Sacca, J; Houénassi, M
2017-02-01
We report the case of a patient with pacemaker who presented chest pain during exercise followed by fainting. He has a history of arterial hypertension and diabetes. The initial examination was normal; the ventricular stimulation threshold was 1.125 volts (V) and cardiac enzymes were normal. Stress test has reproduced chest pain followed by loss of pacemaker capture and asystole. Coronary angiography showed a tight stenosis of the proximal anterior interventricular artery dilated by a drug-eluting stent. The control of stress test was normal. A stent thrombosis eight days later led to an acute coronary syndrome with recurrent syncope due to the loss of ventricular capture. The ventricular pacing threshold was then 2.25V. After revascularization and stabilization of the patient's clinical status, this threshold returned to 1.125V. This clinic case has confirmed that coronary artery disease could increase pacing threshold. It also highlights the usefulness of automatic capture algorithms in coronary patients. The stress test cannot only help to detect coronary artery disease but also allows the optimization of programming the pacemaker. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Kandzari, David E.; Smits, Pieter C.; Love, Michael P.; Ben-Yehuda, Ori; Banai, Shmuel; Rob-inson, Simon D.; Jonas, Michael; Kornowski, Ran; Bagur, Rodrigo; Iniguez, Andres; Danenberg, Haim; Feldman, Robert; Jauhar, Rajiv; Chandna, Harish; Parikh, Manish; Perlman, Gidon Y.; Balcells, Mer-cedes; Markham, Peter; Ozan, Melek Ozgu; Genereux, Philippe; Edelman, Elazer R.; Leon, Martin B.; Stone, Gregg W.
2018-01-01
BACKGROUND The safety and efficacy of a novel cobalt alloy-based coronary stent with a durable elastomeric polymer eluting the antiproliferative agent ridaforolimus for treatment of patients with coronary artery disease is undetermined. METHODS A prospective, international 1:1 randomized trial was conducted to evaluate in a noninferiority design the relative safety and efficacy of ridaforolimus-eluting stents (RESs) and slow-release zotarolimus-eluting stents among 1919 patients undergoing percutaneous coronary intervention at 76 centers. Inclusion criteria allowed enrollment of patients with recent myocardial infarction, total occlusions, bifurcations lesions, and other complex conditions. RESULTS Baseline clinical and angiographic characteristics were similar between the groups. Overall, mean age was 63.4 years, 32.5% had diabetes mellitus, and 39.7% presented with acute coronary syndromes. At 12 months, the primary end point of target lesion failure (composite of cardiac death, target vessel-related myocardial infarction, and target lesion revascularization) was 5.4% for both devices (upper bound of 1-sided 95% confidence interval 1.8%, Pnoninferiority=0.001). Definite/probable stent thrombosis rates were low in both groups (0.4% RES versus 0.6% zotarolimus-eluting stent, P=0.75); 13-month angiographic in-stent late lumen loss was 0.22±0.41 mm and 0.23±0.39 mm (Pnoninferiority=0.004) for the RES and zotarolimus-eluting stent groups, respectively, and intravascular ultrasound percent neointimal hyperplasia was 8.10±5.81 and 8.85±7.77, respectively (Pnoninferiority=0.01). CONCLUSIONS In the present trial, which allowed broad inclusion criteria, the novel RESs met the prespecified criteria for noninferiority compared with zotarolimus-eluting stents for the primary end point of target lesion failure at 12 months and had similar measures of late lumen loss. These findings support the safety and efficacy of RESs in patients who are representative of clinical practice. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01995487. PMID:28794001
Nanoparticle Drug- and Gene-eluting Stents for the Prevention and Treatment of Coronary Restenosis
Yin, Rui-Xing; Yang, De-Zhai; Wu, Jin-Zhen
2014-01-01
Percutaneous coronary intervention (PCI) has become the most common revascularization procedure for coronary artery disease. The use of stents has reduced the rate of restenosis by preventing elastic recoil and negative remodeling. However, in-stent restenosis remains one of the major drawbacks of this procedure. Drug-eluting stents (DESs) have proven to be effective in reducing the risk of late restenosis, but the use of currently marketed DESs presents safety concerns, including the non-specificity of therapeutics, incomplete endothelialization leading to late thrombosis, the need for long-term anti-platelet agents, and local hypersensitivity to polymer delivery matrices. In addition, the current DESs lack the capacity for adjustment of the drug dose and release kinetics appropriate to the disease status of the treated vessel. The development of efficacious therapeutic strategies to prevent and inhibit restenosis after PCI is critical for the treatment of coronary artery disease. The administration of drugs using biodegradable polymer nanoparticles as carriers has generated immense interest due to their excellent biocompatibility and ability to facilitate prolonged drug release. Despite the potential benefits of nanoparticles as smart drug delivery and diagnostic systems, much research is still required to evaluate potential toxicity issues related to the chemical properties of nanoparticle materials, as well as to their size and shape. This review describes the molecular mechanism of coronary restenosis, the use of DESs, and progress in nanoparticle drug- or gene-eluting stents for the prevention and treatment of coronary restenosis. PMID:24465275
DOE Office of Scientific and Technical Information (OSTI.GOV)
Radeleff, Boris, E-mail: Boris.radeleff@med.uni-heidelberg.de; Thierjung, Heidi; Stampfl, Ulrike
2008-09-15
PurposeTo date no direct experimental comparison between the CYPHER-Select and TAXUS-Express stents is available. Therefore, we investigated late in-stent stenosis, thrombogenicity, and inflammation, comparing the CYPHER-Select, TAXUS-Express, and custom-made cobalt chromium Polyzene-F nanocoated stents (CCPS) in the minipig coronary artery model.MethodsThe three stent types were implanted in the right coronary artery of 30 minipigs. The primary endpoint was in-stent stenosis assessed by quantitative angiography and microscopy. Secondary endpoints were inflammation and thrombogenicity evaluated by scores for inflammation and immunoreactivity (C-reactive protein and transforming growth factor beta). Follow-up was at 4 and 12 weeks.ResultsStent placement was successful in all animals; nomore » thrombus deposition occurred. Quantitative angiography did not depict statistically significant differences between the three stent types after 4 and 12 weeks. Quantitative microscopy at 4 weeks showed a statistically significant thicker neointima (p = 0.0431) for the CYPHER (105.034 {+-} 62.52 {mu}m) versus the TAXUS (74.864 {+-} 66.03 {mu}m) and versus the CCPS (63.542 {+-} 39.57 {mu}m). At 12 weeks there were no statistically significant differences. Inflammation scores at 4 weeks were significantly lower for the CCPS and CYPHER compared with the TAXUS stent (p = 0.0431). After 12 weeks statistical significance was only found for the CYPHER versus the TAXUS stent (p = 0.0431). The semiquantitative immunoreactivity scores for C-reactive protein and transforming growth factor beta showed no statistically significant differences between the three stent types after 4 and 12 weeks.ConclusionsThe CCPS provided effective control of late in-stent stenosis and thrombogenicity in this porcine model compared with the two drug-eluting stents. Its low inflammation score underscores its noninflammatory potential and might explain its equivalence to the two DES.« less
Acute ST-Elevation Myocardial Infarction after Coronary Stent Fracture.
Rafighdust, Abbasali; Eshraghi, Ali
2015-10-27
The invention of the drug-eluting stent (DES) has brought about revolutionary changes in the field of interventional cardiology. In the DES era, in-stent restenosis has declined but new issues such as stent thrombosis have emerged. One of the emerging paradigms in the DES era is stent fracture. There are reports about stent fracture leading to in-stent restenosis or stent thrombosis. Most of these reports concern the Sirolimus-eluting stent. The present case is a representation of a Biolimus-eluting stent fracture. We introduce a 64-year-old male patient, for whom the BioMatrix stent was deployed in the right coronary artery. Five months after the implantation, he experienced acute myocardial infarction, with stent fracture leading to stent thrombosis being the causative mechanism. Another DES (Cypher) was used to manage this situation, and the final result was good.
Materials and Manufacturing Technologies Available for Production of a Pediatric Bioabsorbable Stent
Alexy, Ryan D.; Levi, Daniel S.
2013-01-01
Transcatheter treatment of children with congenital heart disease such as coarctation of the aorta and pulmonary artery stenosis currently involves the use of metal stents. While these provide good short term results, there are long term complications with their use. Children outgrow metal stents, obligating them to future transcatheter dilations and eventual surgical removal. A bioabsorbable stent, or a stent that goes away with time, would solve this problem. Bioabsorbable stents are being developed for use in coronary arteries, however these are too small for use in pediatric congenital heart disease. A bioabsorbable stent for use in pediatric congenital heart disease needs to be low profile, expandable to a diameter 8 mm, provide sufficient radial strength, and absorb quickly enough to allow vessel growth. Development of absorbable coronary stents has led to a great understanding of the available production techniques and materials such as bioabsorbable polymers and biocorrodable metals. Children with congenital heart disease will hopefully soon benefit from the current generation of bioabsorbable and biocorrodable materials and devices. PMID:24089660
Lee, Michael S; Yang, Tae; Lasala, John; Cox, David
2016-11-15
The purpose of this study was to evaluate clinical outcomes after percutaneous coronary intervention (PCI) in patients with coronary artery calcification (CAC). Smaller studies have reported worse clinical outcomes in patients with CAC who undergo PCI. The impact of CAC in the drug-eluting stent era is unclear. Data from 7,492 patients treated by PCI with ≥1 TAXUS Express stent in the ARRIVE registry with no inclusion/exclusion criteria were stratified by the severity of CAC, as determined by the operator. Endpoints were independently adjudicated. All major adverse cardiac events were assessed at 2 years. Moderate/severe CAC was present in 19.6%. The nil/mild CAC group had higher rate of current smokers. The moderate/severe CAC group was older and had a higher prevalence of hypertension, kidney disease, prior coronary artery bypass grafting, congestive heart failure, and left main disease. After adjustment for imbalanced baseline variables, patients with moderate/severe CAC had higher 2 year rates of major adverse cardiac events (18.3% vs 13.5%, p = 0.01) and death (10.3% vs 5.6%, p = 0.02). Moderate/severe CAC was associated with increased clinical events in patients who underwent PCI with TAXUS stents. This may be explained in part due to differences important baseline characteristics including more patients with more comorbidities and more complex lesions. After adjustment for imbalanced baseline variables, the moderate/severe CAC group had a higher risk of major adverse cardiac events and death. Improvements in treatment strategies are needed for this high-risk group of patients who undergo PCI. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Sim, Doo Sun; Ahn, Youngkeun; Kim, Young Jo; Chae, Shung Chull; Hong, Taek Jong; Seong, In Whan; Chae, Jei Keon; Kim, Chong Jin; Cho, Myeong Chan; Seung, Ki Bae; Park, Seung Jung
2011-01-01
This study compared clinical outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in large coronary arteries in patients with acute myocardial infarction (MI). A total of 985 patients who underwent single-vessel percutaneous coronary intervention (PCI) in large coronary arteries (≥ 3.5 mm) in lesions < 25 mm were divided into DES group (n = 841) and BMS group (n = 144). Clinical outcomes during 12 months were compared. In-hospital outcome was similar between the groups. At six months, death/MI rate was not different. However, DES group had significantly lower rates of target-lesion revascularization (TLR) (1.7% vs 5.6%, P = 0.021), target-vessel revascularization (TVR) (2.2% vs 5.6%, P = 0.032), and total major adverse cardiac events (MACE) (3.4% vs 11.9%, P = 0.025). At 12 months, the rates of TLR and TVR remained lower in the DES group (2.5% vs 5.9%, P = 0.032 and 5.9% vs 3.1%, P = 0.041), but the rates of death/MI and total MACE were not statistically different. The use of DES in large vessels in the setting of acute MI is associated with lower need for repeat revascularization compared to BMS without compromising the overall safety over the course of one-year follow-up. PMID:21468259
Park, S W; Hong, M K; Lee, C W; Kim, J J; Park, H K; Cho, G Y; Kang, D H; Song, J K; Park, S J
2000-08-01
The GFX stent is a balloon-expandable stent made of sinusoidal element of stainless steel. The adjunct high-pressure balloon dilatations were usually recommended in routine stenting procedure. The aim of this study was to evaluate the immediate and long-term clinical and angiographic outcomes and to investigate the necessity of high-pressure balloon dilatation during GFX stenting. In all, 172 consecutive patients underwent single 12 or 18 mm GFX stent implantation in 188 native coronary lesions. Two types of stenting technique were used: (1) stent size of a final stent-to-artery ratio of 1:1 (inflation pressure > 10 atm, high-pressure group), and (2) stent size of 0.5 mm bigger than reference vessel (inflation pressure < or = 10 atm, low-pressure group). The adjunct high-pressure balloon dilatations were performed only in cases of suboptimal results. The adjunct high-pressure balloon dilatation was required in 11 of 83 lesions (13%) in the high-pressure group and in 7 of 105 lesions (7%) in the low-pressure group (p = 0.203). Procedural success rate was 100%. There were no significant differences of in-hospital and long-term clinical events between the two groups. The overall angiographic restenosis rate was 17.7%; 18.4% in the high-pressure group and 17.1% in the low-pressure group (p = 0.991). The GFX stent is a safe and effective device with a high procedural success rate and favorable late clinical outcome for treatment of native coronary artery disease. Further randomized trials may be needed to compare stenting techniques in GFX stent implantation.
Factors that affect mass transport from drug eluting stents into the artery wall
2010-01-01
Coronary artery disease can be treated by implanting a stent into the blocked region of an artery, thus enabling blood perfusion to distal vessels. Minimally invasive procedures of this nature often result in damage to the arterial tissue culminating in the re-blocking of the vessel. In an effort to alleviate this phenomenon, known as restenosis, drug eluting stents were developed. They are similar in composition to a bare metal stent but encompass a coating with therapeutic agents designed to reduce the overly aggressive healing response that contributes to restenosis. There are many variables that can influence the effectiveness of these therapeutic drugs being transported from the stent coating to and within the artery wall, many of which have been analysed and documented by researchers. However, the physical deformation of the artery substructure due to stent expansion, and its influence on a drugs ability to diffuse evenly within the artery wall have been lacking in published work to date. The paper highlights previous approaches adopted by researchers and proposes the addition of porous artery wall deformation to increase model accuracy. PMID:20214774
Coronary revascularization and adverse events in joint arthroplasty.
Tabatabaee, Reza Mostafavi; Rasouli, Mohammad R; Rezapoor, Maryam; Maltenfort, Mitchell G; Ong, Alvin C; Parvizi, Javad
2015-09-01
There is a paucity of literature about outcome of total joint arthroplasty in patients with the history of angioplasty and/or stent or coronary artery bypass graft (CABG). The present study aimed to evaluate perioperative complications and mortality in these patients. We used the Nationwide Inpatient Sample data from 2002-2011. Using the Ninth Revision of the International Classification of Disease, Clinical Modification codes for disorders and procedures, we identified patients with a history of coronary revascularization (angioplasty and/or stent or CABG) and compared the inhospital adverse events in these patients with patients without a history of coronary revascularization. Cardiac complications occurred in 1.06% patients with a history of CABG; 0.95% of patients with a coronary angioplasty and/or stent and 0.82% of the control patients. In the multivariate analysis, neither the history of CABG (P = 0.07) nor the history of angioplasty and/or stenting (P = 0.86) was associated with a higher risk of cardiac complications. However, myocardial infarction occurred in a significantly higher proportion of patients with the history of CABG (0.66%, odds ratio, 1.24, P = 0.001) and coronary angioplasty and/or stenting (0.67%, odds ratio, 1.96, P < 0.001) compared with that in the controls (0.27%). History of coronary revascularization did not increase the risk of respiratory, renal, and wound complications, surgical site infection, and mortality. Based on the findings of this study, it appears that there is no increased risk of inhospital mortality and complications (except for myocardial infarction) in patients with a history of coronary artery revascularization undergoing total joint arthroplasty. We also found perioperative cardiac arrhythmia, particularly atrial fibrillation, to be an independent predictor of inhospital adverse events. Copyright © 2015 Elsevier Inc. All rights reserved.
ZHANG, XUMIN; WANG, XIAODONG; ZHOU, XIAOHUI; MA, XIAOYE; YAO, YIAN; LIU, XUEBO
2016-01-01
The current study aimed to investigate the relevance of the gap junction protein connexin Cx43 in coronary artery smooth muscle cell (SMC) heterogeneity and coronary artery restenosis. SMCs were isolated from the coronary artery of 3-month-old pigs using enzymatic digestion. Two distinct SMC populations were isolated: Rhomboid (R) and spindle-shaped (S) cells. S-SMCs exhibited relatively lower rates of proliferation, exhibiting a classic ''hills-and valleys'' growth pattern; R-SMCs displayed increased proliferation rates, growing as mono- or multi-layers. Immunofluorescent staining, polymerase chain reaction and western blotting were used to assess the expression of Cx40 and Cx43 in SMCs. For further evaluation, cultured SMCs were treated with 10 ng/ml platelet-derived growth factor (PDGF)-BB with or without the gap junction blocker 18α-glycyrrhetinic acid. Stent-induced restenosis was assessed in vivo. Different expression patterns were observed for Cx40 and Cx43 in R- and S-SMCs. Cx40 was the most abundant Cx in S-SMCs, whereas CX43 was identified at relatively higher levels than Cx40 in R-SMCs. Notably, PDGF-BB converted S-SMCs to R-SMCs, with increased Cx43 expression, while 18α-glycyrrhetinic acid inhibited the PDGF-BB-induced phenotypic alterations in S-SMCs. Additionally, restenosis was confirmed in pigs 1-month subsequent to stent placement. R-SMCs were the major cell population isolated from stent-induced restenosis artery tissues, and exhibited markedly increased Cx43 expression, in accordance with the in vitro data described above. In conclusion, the phenotypic transformation of coronary artery SMCs is closely associated with Cx43, which is involved in restenosis. These observations provide a basis for the use of Cx43 as a novel target in restenosis prevention. PMID:27175888
Combining PCI and CABG: the role of hybrid revascularization.
Green, Kelly D; Lynch, Donald R; Chen, Tyffany P; Zhao, David
2013-04-01
Hybrid coronary revascularization combines the benefits of both percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) in the treatment of multivessel coronary artery disease (CAD) by combining the benefits of the LIMA-to-LAD graft and drug eluting stent (DES) to non-LAD regions. Through this approach, a patient receives the long-term benefit of the LIMA graft and avoids the morbidity of a full sternotomy and saphenous vein grafts. Available data related to outcomes following hybrid revascularization is limited to small studies. In this review we seek to provide an overview of hybrid revascularization in the era of modern drug eluting stent technology, discuss appropriate patient selection, and comment on future trial design. Additionally, we review the recent literature pertaining to the hybrid approach.
Aneurysmal coronary artery disease: An overview
ElGuindy, Mohamed S.
Aneurysmal coronary artery disease (ACAD) comprises both coronary artery aneurysms (CAA) and coronary artery ectasia (CAE). The reported prevalence of ACAD varies widely from 0.2 to 10%, with male predominance and a predilection for the right coronary artery (RCA). Atherosclerosis is the commonest cause of ACAD in adults, while Kawasaki disease is the commonest cause in children and adolescents, as well as in the Far East. Most patients are asymptomatic, but when symptoms do exist, they are usually related to myocardial ischemia. Coronary angiography is the mainstay of diagnosis, but follow up is best achieved using noninvasive imaging that does not involve exposure to radiation. The optimal management strategy in patients with ACAD remains controversial. Medical therapy is indicated for the vast majority of patients and includes antiplatelets and/or anticoagulants. Covered stents effectively limit further expansion of the affected coronary segments. Surgical ligation, resection, and coronary artery bypass grafting are appropriate for large lesions and for associated obstructive coronary artery disease. PMID:29564347
[The bioresorbable coronary stent: a revolution].
Koegler, Flora; De Benedetti, Edoardo
2013-04-10
Coronary angioplasty has undergone several technological revolutions: starting with balloon angioplasty, then with bare metal stent and finally with drug eluting stent (DES), this technique is now mature. However, once we thought the problem of instent restenosis solved with DES, new concerns arise with late and very late stent thrombosis. Should we therefore proscribe DES? How long should be the duration of dual antiplatelet therapy? And how should we manage the patients who need a surgery and are at high risk of bleeding? Are bioresorbable stents the final solution with their initial mechanical properties, then with their drug eluting effect against intra-stent restenosis, and finally with their complete resorption which leaves the artery free of any foreign material?
Rizik, David G; Klag, Joseph M; Tenaglia, Alan; Hatten, Thomas R; Barnhart, Marianne; Warnack, Boris
2009-12-01
Provisional T-stenting is a widely used strategy for the treatment of coronary artery bifurcation lesions. However, the use of conventional stents in this setting is limited by multiple factors; this includes technical considerations such as wire wrap when accessing the involved vessel, and stent overlap at or near the carina of the lesion. In addition, current slotted tube stent technology tends to be associated with gaps in the coverage of the side branch ostium, which may result in restenosis in that segment of the lesion. The Pathfinder device, now more commonly referred to as the Xience Side Branch Access System (Xience SBA) is a drug-eluting stent (DES) designed specifically to assist in the treatment of bifurcation lesions by allowing wire access into the side branch, irrespective of the treatment strategy to be employed. The Xience SBA drug-eluting stent was compared with the standard Vision coronary stent system using a provisional T-stenting strategy in a perfused synthetic model of the coronary vasculature with side branch angulations of 30 degrees , 50 degrees , 70 degrees , and 90 degrees . Stent delivery was performed under fluoroscopic guidance. Following the procedure, high-resolution 2D Faxitron imaging was used to evaluate deployment accuracy of the side branch stent relative to the main branch stent. Deployment of the Xience SBA was accomplished in the same total time as the standard stents in a provisional T-stenting approach (14.9 vs. 14.6 minutes). However, the time required to achieve stent deployment in the main branch was less with the Xience SBA (4.0 vs. 6.6 minutes), and as a result, total contrast usage (49.4 vs. 69.4 cm(3)) and fluoroscopy time (5.1 vs. 6.2 minutes) was lower. Additionally, the Xience SBA had a lower incidence of wire wrap (22% vs. 89%) and less distal protrusion of the side branch stent into the main branch (0.54 vs. 1.21 mm). Significant gaps in ostial side branch coverage were not seen in either group. The Xience Side Branch Access DES is a viable device for consistently accessing coronary bifurcation lesions; it allows for easy wire access into the side branch. This may assist the operator in overcoming those well-recognized limitations associated with use of standard one- or two-stent strategies. In this perfused synthetic coronary model, Xience SBA deployment required less contrast usage and shorter fluoroscopy times. Further testing of this device is warranted.
Simulation of blood flow using extended Boltzmann kinetic approach
NASA Astrophysics Data System (ADS)
Chen, Caixia; Chen, Hudong; Freed, David; Shock, Richard; Staroselsky, Ilya; Zhang, Raoyang; Ümit Coşkun, A.; Stone, Peter H.; Feldman, Charles L.
2006-03-01
Lattice Boltzmann (LB) simulations are conducted to obtain the detailed hydrodynamics in a variety of blood vessel setups, including a prototype stented channel and four human coronary artery geometries based on the images obtained from real patients. For a model of stented flow involving an S-shape stent, a pulsatile flow rate is applied as the inlet boundary condition, and the time- and space-dependent flow field is computed. The LB simulation is found to reproduce the analytical solutions for the velocity profiles and wall shear stress distributions for the pulsatile channel flow. For the coronary arteries, the distributions of wall shear stress, which is important for clinical diagnostic purposes, are in good agreement with the conventional CFD predictions.
Jelenc, Matija; Kneževič, Ivan; Stankovič, Milenko; Geršak, Borut
2012-01-01
We present a case of a 62-year old man with a left main stenosis, left coronary artery dominance, normal ejection fraction and no valvular pathology, and status post right carotid artery stenting, who was scheduled for elective coronary revascularization. We performed off-pump coronary revascularization, anastomosing the left internal thoracic artery to the left anterior descending artery, and three separate saphenous vein grafts to the intermediate artery and the first and second obtuse marginals, respectively. Proximally, the right internal thoracic artery was used as the inflow for all three venous grafts due to a heavily calcified ascending aorta. During the construction of the distal anastomoses to the obtuse marginals, the arterial pressure in the left radial artery suddenly dropped. The left hand was found to be pale and pulseless. A femoral artery catheter was placed for pressure monitoring and the anastomoses were completed as planned. Intraoperative transit-time graft flow measurement showed a reversed flow in the left internal thoracic artery. Postoperatively, angiography was performed showing a subtotal stenosis of the proximal left subclavian artery. The artery was dilated and stented. The postoperative course was uneventful and the patient was discharged on the 12th postoperative day. PMID:22767542
Biodegradable Polymers Influence the Effect of Atorvastatin on Human Coronary Artery Cells
Strohbach, Anne; Begunk, Robert; Petersen, Svea; Felix, Stephan B.; Sternberg, Katrin; Busch, Raila
2016-01-01
Drug-eluting stents (DES) have reduced in-stent-restenosis drastically. Yet, the stent surface material directly interacts with cascades of biological processes leading to an activation of cellular defense mechanisms. To prevent adverse clinical implications, to date almost every patient with a coronary artery disease is treated with statins. Besides their clinical benefit, statins exert a number of pleiotropic effects on endothelial cells (ECs). Since maintenance of EC function and reduction of uncontrolled smooth muscle cell (SMC) proliferation represents a challenge for new generation DES, we investigated the effect of atorvastatin (ATOR) on human coronary artery cells grown on biodegradable polymers. Our results show a cell type-dependent effect of ATOR on ECs and SMCs. We observed polymer-dependent changes in IC50 values and an altered ATOR-uptake leading to an attenuation of statin-mediated effects on SMC growth. We conclude that the selected biodegradable polymers negatively influence the anti-proliferative effect of ATOR on SMCs. Hence, the process of developing new polymers for DES coating should involve the characterization of material-related changes in mechanisms of drug actions. PMID:26805825
Primary and Secondary Prevention of Cardiovascular Disease
Vandvik, Per Olav; Lincoff, A. Michael; Gore, Joel M.; Gutterman, David D.; Sonnenberg, Frank A.; Alonso-Coello, Pablo; Akl, Elie A.; Lansberg, Maarten G.; Guyatt, Gordon H.
2012-01-01
Background: This guideline focuses on long-term administration of antithrombotic drugs designed for primary and secondary prevention of cardiovascular disease, including two new antiplatelet therapies. Methods: The methods of this guideline follow those described in Methodology for the Development of Antithrombotic Therapy and Prevention of Thrombosis Guidelines: Antithrombotic Therapy and Prevention of Thrombosis, 9th ed: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines in this supplement. Results: We present 23 recommendations for pertinent clinical questions. For primary prevention of cardiovascular disease, we suggest low-dose aspirin (75-100 mg/d) in patients aged > 50 years over no aspirin therapy (Grade 2B). For patients with established coronary artery disease, defined as patients 1-year post-acute coronary syndrome, with prior revascularization, coronary stenoses > 50% by coronary angiogram, and/or evidence for cardiac ischemia on diagnostic testing, we recommend long-term low-dose aspirin or clopidogrel (75 mg/d) (Grade 1A). For patients with acute coronary syndromes who undergo percutaneous coronary intervention (PCI) with stent placement, we recommend for the first year dual antiplatelet therapy with low-dose aspirin in combination with ticagrelor 90 mg bid, clopidogrel 75 mg/d, or prasugrel 10 mg/d over single antiplatelet therapy (Grade 1B). For patients undergoing elective PCI with stent placement, we recommend aspirin (75-325 mg/d) and clopidogrel for a minimum duration of 1 month (bare-metal stents) or 3 to 6 months (drug-eluting stents) (Grade 1A). We suggest continuing low-dose aspirin plus clopidogrel for 12 months for all stents (Grade 2C). Thereafter, we recommend single antiplatelet therapy over continuation of dual antiplatelet therapy (Grade 1B). Conclusions: Recommendations continue to favor single antiplatelet therapy for patients with established coronary artery disease. For patients with acute coronary syndromes or undergoing elective PCI with stent placement, dual antiplatelet therapy for up to 1 year is warranted. PMID:22315274
Successful embolization of iatrogenic ruptured coronary artery using Onyx: a new technique.
Asouhidou, I; Katsaridis, V
2014-12-01
Iatrogenic perforation of coronary artery is rare during percutaneous coronary intervention (PCI); however the complications are life-threatening. Patients in this clinical setting may be treated either by stent placement, closure of the perforation with fibrin glue or coils, or with emergency bypass surgery. Onyx, a new material that has been used successfully in cerebral arteries, represents a new and safe alternative. The advantage of Onyx is that it is easily injected through a microcatheter and it allows for a longer injection time having also the ability to reach difficult anatomical locations. We present the first case of successful embolization of a right coronary artery perforation during coronary angiography using Onyx.
Fragoso, Jose Manuel; Alvarez-León, Edith; Delgadillo-Rodríguez, Hilda; Arellano-González, Marva; López-Pacheco, Filogonio Caín; Cruz-Robles, David; Peña-Duque, Marco Antonio; Pérez-Méndez, Oscar; Martínez-Ríos, Marco Antonio; Vargas-Alarcón, Gilberto
2015-08-01
The aim of the present study was to evaluate the role of AGT and REN gene polymorphisms as susceptibility markers for coronary artery disease (CAD) and/or restenosis after coronary stent placement in a group of Mexican patients. Five polymorphisms of the AGT (rs699, rs4762, rs5051, rs5049, rs5046) and two of the REN (rs5707, rs5705) genes were analyzed by 5' exonuclease TaqMan genotyping assays in 240 patients with CAD who underwent coronary artery stenting (76 with restenosis and 164 without restenosis). A group of 610 individuals without clinical and familial antecedents of cardiovascular diseases were included as controls. The results showed that the distribution of AGT and REN polymorphisms were similar in patients with and without restenosis. However, when the whole group of patients (with and without restenosis) was compared to healthy controls, under co-dominant, dominant, heterozygous and additive models, the REN A4280C (rs5705) polymorphism was associated with increased risk of CAD (OR=1.76, PCo-dom=0.006, OR=1.81, PDom=0.001, OR=1.75, PHet=0.003 and OR=1.59, PAdd=0.003, respectively). All models were adjusted for age, gender, diabetes, dyslipidemia, hypertension and smoking habit. The TC haplotype of the REN gene was associated with increased risk of CAD (OR=1.53, P=0.014). The data suggest that the REN C4280A (rs5705) polymorphism plays an important role in the risk of developing CAD with the highest risk for C allele, but do not support its role as a risk factor for developing restenosis after coronary stenting. Copyright © 2015. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Gao, Long-yue; Zhou, Wei-qi; Wang, Yuan-bo; Wang, Si-qi; Bai, Chong; Li, Shi-ming; Liu, Bin; Wang, Jun-nan; Cui, Cheng-kun; Li, Yong-liang
2016-05-01
To solve the problems with coronary stent implantation, coronary artery stent surface was directly modified by three-beam laser interference lithography through imitating the water-repellent surface of lotus leaf, and uniform micro-nano structures with the controllable period were fabricated. The morphological properties and contact angle (CA) of the microstructure were measured by scanning electron microscope (SEM) and CA system. The water repellency of stent was also evaluated by the contact and then separation between the water drop and the stent. The results show that the close-packed concave structure with the period of about 12 μm can be fabricated on the stent surface with special parameters (incident angle of 3°, laser energy density of 2.2 J·cm-2 and exposure time of 80 s) by using the three-beam laser at 1 064 nm, and the structure has good water repellency with CA of 120°.
Pellicano, Mariano; Floré, Vincent; Barbato, Emanuele; De Bruyne, Bernard
2018-06-19
Percutaneous coronary interventions (PCI) of old calcified saphenous vein grafts (SVGs) is challenging and is associated with a considerably high risk of adverse ischemic events in the short- and long-term as compared to native coronary arteries. We report a case in which a non-dilatable, calcified SVG lesion is successfully treated with rotational atherectomy followed by PCI and stenting with local stent delivery (LSD) technique using the Guidezilla™ guide extension catheter (5-in-6 Fr) in the "child-in-mother" fashion. A 70 years-old man with a dilated ischemic cardiomyopathy, triple coronary artery bypass grafting (CABG) in 1990 and chronic renal failure (baseline GFR: 45 ml/min/1.73 m 2 ) underwent a coronary angiography for a Non-ST segment elevation myocardial infarction (NSTEMI). Native coronary circulation was completely occluded at the proximal segments. Grafts angiography showed a tandem calcified lesions of SVG on distal right coronary artery (RCA) and an ostial stenosis of the SVG on first obtuse marginal branch (OM1). Left internal mammary artery on the mid left anterior descending artery was patent. Ad Hoc PCI of SVG on RCA was attempted. The proximal calcified stenosis has been crossed with a 1.5 x 12 mm balloon only with the support of Guidezilla™, however the non-compliant (NC) balloon 2.5 x 15 mm was unable to break the hard and calcified plaque. After several attempts, the procedure was interrupted with a suboptimal result. An elective transradial PCI of SVG on RCA with rotational atherectomy was performed. Two runs with 1.25 mm burr and 2 runs with 1.5 mm burr were carried out. Then, the use of distal anchoring balloon warranted support and tracking, made as centring rail for the advance of the tip of the "mother-and-child" catheter into the SVG. During slow deflation of the balloon, the Guidezilla™ was advanced distal to the stenoses to be stented, thus allowing the placement of two long drug eluting stents according to a LSD technique. Rotational atherectomy is a feasible option for non-dilatable stenoses in old SVGs when there is no evidence of thrombus or vessel dissection and the subsequent use of "mother-and-child" catheter has a key role, especially in case of radial approach, for long stents delivery.
Do Indo-Asians have smaller coronary arteries?
Lip, G Y; Rathore, V S; Katira, R; Watson, R D; Singh, S P
1999-08-01
There is a widespread belief that coronary arteries are smaller in Indo-Asians. The aim of the present study was to compare the size of atheroma-free proximal and distal epicardial coronary arteries of Indo-Asians and Caucasians. We analysed normal coronary angiograms from 77 Caucasians and 39 Indo-Asians. The two groups were comparable for dominance of the coronary arteries. Indo-Asian patients had generally smaller coronary arteries, with a statistically significant difference in the mean diameters of the left main coronary artery, proximal, mid and left anterior descending, and proximal and distal right coronary artery segments. There was a non-significant trend towards smaller coronary artery segment diameters for the distal left anterior descending, proximal and distal circumflex, and obtuse marginal artery segments. However, after correction for body surface area, none of these differences in size were statistically significant. Thus, the smaller coronary arteries in Indo-Asian patients were explained by body size alone and were not due to ethnic origin per se. This finding nevertheless has important therapeutic implications, since smaller coronary arteries may give rise to technical difficulties during bypass graft and intervention procedures such as percutaneous transluminal coronary angioplasty, stents and atherectomy. On smaller arteries, atheroma may also give an impression of more severe disease than on larger diameter arteries.
Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard
2016-01-01
Objectives We evaluated the safety and efficacy of orbital atherectomy in real‐world patients with severe coronary artery calcification (CAC). Background The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. Methods This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. Results The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30‐day all‐cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no‐reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. Conclusion In the largest real‐world study of patients who underwent orbital atherectomy, including high‐risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short‐term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. PMID:27358246
Sim, Doo Sun; Jeong, Myung Ho; Cha, Kyoung Rae; Park, Suk Ho; Park, Jong Oh; Shin, Young Min; Shin, Heungsoo; Hong, Young Joon; Ahn, Youngkeun; Schwartz, Robert S; Kang, Jung Chaee
2012-12-01
Chronic total occlusion (CTO) remains a challenge in interventional cardiology. We investigated the feasibility and reliability of copper wire stents and levo-polylactic acid (l-PLA) as a means of CTO induction in a porcine model. In one group of 20 swine, copper stents were crimped on a 3.0mm angioplasty balloon and inserted into the mid-left anterior descending coronary artery (LAD). In the other group of 20 swine, l-PLA was wrapped on a guidewire and pushed into the distal LAD with a 3.0mm balloon catheter to induce embolization. Of 20 swine which underwent copper stent implantation, 13 died of stent thrombosis. In the remaining 7 swine, total or near total occlusion with collateral circulation was observed at 5 weeks. Of 20 swine which underwent l-PLA embolization, 4 died of ventricular fibrillation during or shortly after the procedure. Serial histopathologic studies showed complete absorption of the polymer with replacement by fibrotic tissue approximately 4 weeks following the polymer implantation. CTO could be reliably induced in porcine coronary arteries by copper stents and l-PLA. These models may support investigation of new percutaneous devices to facilitate CTO interventions. Copyright © 2012 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Intravascular local gene transfer mediated by protein-coated metallic stent.
Yuan, J; Gao, R; Shi, R; Song, L; Tang, J; Li, Y; Tang, C; Meng, L; Yuan, W; Chen, Z
2001-10-01
To assess the feasibility, efficiency and selectivity of adenovirus-mediated gene transfer to local arterial wall by protein-coated metallic stent. A replication-defective recombinant adenovirus carrying the Lac Z reporter gene for nuclear-specific beta-galactosidase (Ad-beta gal) was used in this study. The coating for metallic stent was made by immersing it in a gelatin solution containing crosslinker. The coated stents were mounted on a 4.0 or 3.0 mm percutaneous transluminal coronary angioplasty (PTCA) balloon and submersed into a high-titer Ad-beta gal viral stock (2 x 10(10) pfu/ml) for 3 min, and then implanted into the carotid arteries in 4 mini-swines and into the left anterior descending branch of the coronary artery in 2 mini-swines via 8F large lumen guiding catheters. The animals were sacrificed 7 (n = 4), 14 (n = 1) and 21 (n = 1) days after implantation, respectively. The beta-galactosidase expression was assessed by X-gal staining. The results showed that the expression of transgene was detected in all animal. In 1 of carotid artery with an intact intima, the beta-gal expression was limited to endothelial cells. In vessels with denuded endothelium, gene expression was found in the sub-intima, media and adventitia. The transfection efficiency of medial smooth muscle cells was 38.6%. In 2 animals sacrificed 7 days after transfection, a microscopic examination of X-gal-stained samples did not show evidence of transfection in remote organs and arterial segments adjacent to the treated arterial site. Adenovirus-mediated arterial gene transfer to endothelial, smooth muscle cells and adventitia by protein-coated metallic stent is feasible. The transfection efficiency is higher. The coated stent may act as a good carrier of adenovirus-mediated gene transfer and have a potential to prevent restenosis following PTCA.
Clavijo, Leonardo C; Cortes, Guillermo A; Jolly, Aaron; Tun, Han; Mehra, Anilkumar; Gaglia, Michael A; Shavelle, David; Matthews, Ray V
2016-01-01
To compare same-day (SD) vs. delayed hospital discharge (DD) after single and multivessel coronary stenting facilitated by femoral closure device in patients with stable angina and low-risk acute coronary syndrome (ACS). University of Southern California patients were screened and coronary stenting was performed in 2480 patients. Four hundred ninety-three patients met screening criteria and consented. Four hours after percutaneous coronary intervention, 100 were randomized to SD (n=50) or DD (n=50). Patients were followed for one year; outcomes-, patient satisfaction-, and cost analyses were performed. Groups were well distributed, with similar baseline demographic and angiographic characteristics. Mean age was 58.1±8.8years and 86% were male. Non-ST-elevation myocardial infarction and unstable angina were the clinical presentations in 30% and 44% of the SD and DD groups, respectively (p=0.2). Multivessel stenting was performed in 36% and 30% of SD and DD groups, respectively (p=0.14). At one year, two patients from each group (4%) required unplanned revascularization and one patient in the SD group had a gastrointestinal bleed that required a blood transfusion. Six SD and four DD patients required repeat hospitalization (p=0.74). There were no femoral artery vascular complications in either group. Patient satisfaction scores were equivalent. SD discharge was associated with $1200 savings per patient. SD discharge after uncomplicated single and multivessel coronary stenting of patients with stable, low-risk ACS, via the femoral approach facilitated by a closure device, is associated with similar clinical outcomes, patient satisfaction, and cost savings compared to overnight (DD) hospital stay. Copyright © 2016 Elsevier Inc. All rights reserved.
Khattab, Ahmed A; Richardt, Gert; Verin, Vitali; Kelbaek, Henning; Macaya, Carlos; Berland, Jacques; Miquel-Hebert, Karine; Dorange, Cécile; Serruys, Patrick W
2008-03-01
Restenosis is higher among certain subpopulations when subjected to percutaneous coronary interventions even when using drug-eluting stents. The randomised SPIRIT II trial demonstrated the superiority of the XIENCE V Everolimus Eluting Coronary Stent System over the TAXUS Paclitaxel-Eluting Stent System in terms of in-stent late loss at six months among 300 patients treated for de novo native coronary artery lesions. In this post-hoc analysis of SPIRIT II we focused on six-month angiographic outcomes of diabetic patients (n=69), left anterior descending arteries (n=149), long lesions >20 mm (n=43), small vessels <3.0 mm (n=209) and type B2 and C lesions (n=233). In-stent late loss was consistently less among all subgroups when treated by everolimus-eluting stents compared to paclitaxel-eluting stents: diabetics 0.15+/-0.26 mm versus 0.39+/-0.34 mm, p=0.006; LAD 0.12+/-0.23 mm versus 0.44+/-0.37 mm, p<0.001; long lesions 0.13+/-0.26 mm versus 0.43+/-0.46 mm, p=0.070; small vessels 0.17+/-0.28 mm versus 0.37+/-0.39 mm, p<0.001; B2/C lesions 0.12+/-0.31 mm versus 0.36+/-0.36 mm, p<0.001. The everolimus-eluting stent remained superior in terms of in-stent late loss in a variety of higher risk populations for restenosis compared to the paclitaxel-eluting stent. These analyses were consistent with the in-stent late loss results of the overall SPIRIT II trial population.
Diletti, Roberto; Serruys, Patrick W; Farooq, Vasim; Sudhir, Krishnankutty; Dorange, Cecile; Miquel-Hebert, Karine; Veldhof, Susan; Rapoza, Richard; Onuma, Yoshinobu; Garcia-Garcia, Hector M; Chevalier, Bernard
2012-11-01
Currently, no data are available on the direct comparison between the Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb BVS) and conventional metallic drug-eluting stents. The ABSORB II study is a randomized, active-controlled, single-blinded, multicenter clinical trial aiming to compare the second-generation Absorb BVS with the XIENCE everolimus-eluting metallic stent. Approximately 501 subjects will be enrolled on a 2:1 randomization basis (Absorb BVS/XIENCE stent) in approximately 40 investigational sites across Europe and New Zealand. Treated lesions will be up to 2 de novo native coronary artery lesions, each located in different major epicardial vessels, all with an angiographic maximal luminal diameter between 2.25 and 3.8 mm as estimated by online quantitative coronary angiography (QCA) and a lesion length of ≤48 mm. Clinical follow-up is planned at 30 and 180 days and at 1, 2, and 3 years. All subjects will undergo coronary angiography, intravascular ultrasound (IVUS) and IVUS-virtual histology at baseline (pre-device and post-device implantation) and at 2-year angiographic follow-up. The primary end point is superiority of the Absorb BVS vs XIENCE stent in terms of vasomotor reactivity of the treated segment at 2 years, defined as the QCA quantified change in the mean lumen diameter prenitrate and postnitrate administration. The coprimary end point is the noninferiority (reflex to superiority) of the QCA-derived minimum lumen diameter at 2 years postnitrate minus minimum lumen diameter postprocedure postnitrate by QCA. In addition, all subjects allocated to the Absorb BVS group will undergo multislice computed tomography imaging at 3 years. The ABSORB II randomized controlled trial (ClinicalTrials.gov NCT01425281) is designed to compare the safety, efficacy, and performance of Absorb BVS against the XIENCE everolimus-eluting stent in the treatment of de novo native coronary artery lesions. Copyright © 2012 Mosby, Inc. All rights reserved.
Ishihara, Takayuki; Iida, Osamu; Fujita, Masashi; Masuda, Masaharu; Okamoto, Shin; Nanto, Kiyonori; Kanda, Takashi; Tsujimura, Takuya; Sunaga, Akihiro; Awata, Masaki; Nanto, Shinsuke; Uematsu, Masaaki
2018-04-01
Whether arterial repair following implantation of drug-eluting stents (DES) of the second generation differs among stent types remains unknown. We examined 41 DES placed in 28 patients (age 72 ± 7 years, male 89%) presenting with stable angina pectoris due to de novo lesions in native coronary arteries. Coronary angioscopy was performed 4 ± 1 months after stent implantation. Patients were divided into two groups based on the DES types: 22 cobalt-chrome everolimus-eluting stents (CoCr-EES) in 13 patients and 19 slow-release zotarolimus-eluting stents (R-ZES) in 15 patients. Neointimal coverage (NIC) was graded as: grade 0, stent struts exposed; grade 1, struts bulging into the lumen, although covered; grade 2, struts embedded in the neointima, but translucent; grade 3, struts fully embedded and invisible. NIC was defined as heterogeneous when the NIC grade variation was ≥1. Presence of thrombus was also investigated. Distribution of dominant NIC grade (CoCr-EES: grade 0, 9%; grade 1, 77%; grade 2, 9%; grade 3, 5%; R-ZES: grade 0, 16%; grade 1: 47%; grade 2, 37%; grade 3, 0%, P = 0.38) and heterogeneity of NIC (P = 0.43) were similar between CoCr-EES and R-ZES groups. Existence of thrombus was not significantly different in CoCr-EES and R-ZES (18 versus 42%, P = 0.17). Arterial repair occurred without significant differences between CoCr-EES and R-ZES 4 months after implantation.
Campos, Carlos M; van Klaveren, David; Farooq, Vasim; Simonton, Charles A; Kappetein, Arie-Pieter; Sabik, Joseph F; Steyerberg, Ewout W; Stone, Gregg W; Serruys, Patrick W
2015-05-21
To prospectively validate the SYNTAX Score II and forecast the outcomes of the randomized Evaluation of the Xience Everolimus-Eluting Stent Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization (EXCEL) Trial. Evaluation of the Xience Everolimus Eluting Stent vs. Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization is a prospective, randomized multicenter trial designed to establish the efficacy and safety of percutaneous coronary intervention (PCI) with the everolimus-eluting stent compared with coronary artery bypass graft (CABG) surgery in subjects with unprotected left-main coronary artery (ULMCA) disease and low-intermediate anatomical SYNTAX scores (<33). After completion of patient recruitment in EXCEL, the SYNTAX Score II was prospectively applied to predict 4-year mortality in the CABG and PCI arms. The 95% prediction intervals (PIs) for mortality were computed using simulation with bootstrap resampling (10 000 times). For the entire study cohort, the 4-year predicted mortalities were 8.5 and 10.5% in the PCI and CABG arms, respectively [odds ratios (OR) 0.79; 95% PI 0.43-1.50). In subjects with low (≤22) anatomical SYNTAX scores, the predicted OR was 0.69 (95% PI 0.34-1.45); in intermediate anatomical SYNTAX scores (23-32), the predicted OR was 0.93 (95% PI 0.53-1.62). Based on 4-year mortality predictions in EXCEL, clinical characteristics shifted long-term mortality predictions either in favour of PCI (older age, male gender and COPD) or CABG (younger age, lower creatinine clearance, female gender, reduced left ventricular ejection fraction). The SYNTAX Score II indicates at least an equipoise for long-term mortality between CABG and PCI in subjects with ULMCA disease up to an intermediate anatomical complexity. Both anatomical and clinical characteristics had a clear impact on long-term mortality predictions and decision making between CABG and PCI. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2015. For permissions please email: journals.permissions@oup.com.
A novel high nitrogen nickel-free coronary stents system: evaluation in a porcine model.
Zhang, Bin; Chen, Ming; Zheng, Bo; Wang, Xin Gang; Wang, Xi Ting; Fan, Yuan Yuan; Huo, Yong
2014-04-01
To study the safety of the novel high nitrogen nickel-free austenitic stainless steel bare metal stents (BMS) in a recognized porcine coronary model and to select a better grid structure of it. Three types of stents were randomly implanted in different coronary arteries of the same pig: 316 L stainless steel BMS (316 L-BMS) (n=12), novel high nitrogen nickel-free stents Grid A (NF-A-BMS) (n=12) and novel high nitrogen nickel-free stents Grid B (NF-B-BMS) (n=12). In total, eighteen animals underwent successful random placement of 36 oversized stents in the coronary arteries. Coronary angiography was performed after 36 d of stents implantation. Nine animals were respectively sacrificed after 14 d and 36 d for histomorphologic analysis. Quantitative coronary angiography (QCA) showed similar luminal loss (LL) in the three groups: (0.21 ± 0.17) mm for 316 L-BMS, (0.16 ± 0.12) mm for NF-A-BMS, (0.24 ± 0.15) mm for NF-B-BMS (P>0.05). Histomorphomeric analysis after 15 d and 36 d revealed that there was also no significant difference among the three groups in neointimal area (NA) with similar injury scores respectively. High magnification histomorphologic examination showed similar inflammation scores in the three groups, but NF-A-BMS group had poorer endothelialization scores compared with NF-B-BMS group, 2.00 ± 0.63 vs. 2.83 ± 0.41 (P=0.015) at 15 d, which also could be proved by the scanning electron microscope. However, the difference could not been observed at 36 d. The novel NF-BMS showed similar safety as 316 L-BMS during the short-term study. NF-B-BMS had better endothelialization than NF-A-BMS and this may owe to the specific strut units. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Spontaneous coronary artery dissection as a cause of myocardial infarction
Aksakal, Aytekin; Arslan, Uğur; Yaman, Mehmet; Urumdaş, Mehmet; Ateş, Ahmet Hakan
2014-01-01
Spontaneous coronary artery dissection (SCAD) is a rare disease that is usually seen in young women in left descending coronary artery and result in events like sudden cardiac death and acute myocardial infarction. A 70-year-old man was admitted to the emergency department with chest pain which started 1 h ago during a relative’s funeral. The initial electrocardiography demonstrated 2 mm ST-segment depression in leads V1-V3 and the patient underwent emergent coronary angiography. SCAD simultaneously in two different coronary arteries [left anterior descending (LAD) artery and left circumflex (LCx)] artery was detected and SCAD in LCx artery was causing total occlusion which resulted in acute myocardial infarction. Successful stenting was performed thereafter for both lesions. In addition to the existence of SCAD simultaneously in two different coronary arteries, the presence of muscular bridge and SCAD together at the same site of the LAD artery was another interesting point which made us report this case. PMID:25548620
Waseda, Katsuhisa; Ako, Junya; Yamasaki, Masao; Koizumi, Tomomi; Sakurai, Ryota; Hongo, Yoichiro; Koo, Bon-Kwon; Ormiston, John; Worthley, Stephen G; Whitbourn, Robert J; Walters, Darren L; Meredith, Ian T; Fitzgerald, Peter J; Honda, Yasuhiro
2011-06-01
Polymer formulation may affect the efficacy of drug-eluting stents. Resolute, Endeavor, and ZoMaxx are zotarolimus-eluting stents with different stent platforms and different polymer coatings and have been tested in clinical trials. The aim of this analysis was to compare the efficacy of zotarolimus-eluting stents with different polymers. Data were obtained from the first-in man trial or first randomized trials of each stent, The Clinical RESpOnse EvaLUation of the MedTronic Endeavor CR ABT-578 Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions (RESOLUTE), Randomized Controlled Trial to Evaluate the Safety and Efficacy of the Medtronic AVE ABT-578 Eluting Driver Coronary Stent in De Novo Native Coronary Artery Lesions (ENDEAVOR II), and ZoMaxx I trials. Follow-up intravascular ultrasound analyses (8 to 9 months of follow-up) were possible in 353 patients (Resolute: 88, Endeavor: 98, ZoMaxx: 82, Driver: 85). Volume index (volume/stent length) was obtained for vessel, stent, lumen, peristent plaque, and neointima. Cross-sectional narrowing was defined as neointimal area divided by stent area (%). Neointima-free frame ratio was calculated as the number of frames without intravascular ultrasound-detectable neointima divided by the total number of frames within the stent. At baseline, vessel, lumen, and peristent plaque volume index were not significantly different among the 4 stent groups. At follow-up, percent neointimal obstruction was significantly lower in Resolute compared with Endeavor, ZoMaxx, and Driver (Resolute: 3.7±4.0, Endeavor: 17.5±10.1, ZoMaxx: 14.6±8.1, Driver: 29.4±17.2%; P<0.001). Greater maximum cross-sectional narrowing and higher neointima-free frame ratio, suggesting less neointimal coverage, were observed in Resolute compared with other stent groups. Multiple regression analysis confirmed that the biodurable polymer used in Resolute independently correlated with neointimal suppression among 3 zotarolimus-eluting stents. The different polymer formulations significantly affect the relative amount of neointima for zotarolimus-eluting stents. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00248079.
... of coronary artery disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: ... Atherosclerotic peripheral arterial disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil Medicine . 25th ed. Philadelphia, PA: ...
Forrest, John K; Lansky, Alexandra J; Meller, Stephanie M; Hou, Liming; Sood, Poornima; Applegate, Robert J; Wang, John C; Skelding, Kimberly A; Shah, Aakar; Kereiakes, Dean J; Sudhir, Krishnankutty; Cristea, Ecaterina; Yaqub, Manejeh; Stone, Gregg W
2013-06-01
The aim of this study was to determine whether patients from the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Patients With de Novo Native Coronary Artery Lesions (SPIRIT) IV trial who underwent percutaneous coronary intervention, who had target lesions with jailed side branches, had improved clinical outcomes when treated with the XIENCE V versus Taxus Express(2) drug-eluting stent. In the SPIRIT III randomized trial, patients with target lesions with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had lower 2-year rates of major adverse cardiac events. The SPIRIT IV trial represents a larger more diverse patient population compared with SPIRIT III. In the large-scale, prospective, multicenter, randomized SPIRIT IV trial, 3,687 patients who underwent coronary stenting with up to 3 de novo native coronary artery lesions were randomized 2:1 to receive XIENCE V versus Taxus Express(2) stents. Two-year clinical outcomes of patients with or without jailed side branches after stenting were compared. A jailed side branch was defined as any side branch >1.0 mm in diameter within the target segment being stented, excluding bifurcations deemed to require treatment. Of the 3,687 patients in SPIRIT IV, a total of 1,426 had side branches that were jailed during angioplasty of the target lesion. Patients with jailed side branches after XIENCE V compared with Taxus Express(2) implantation had significantly lower 2-year rates of target lesion failure (6.5% vs 11.9%, p = 0.001), major adverse cardiac events (6.6% vs 12.2%, p = 0.0008), ischemia-driven target vessel revascularization (4.1% vs 7.9%, p = 0.004), and stent thrombosis (0.6% vs 2.8%, p = 0.001). In conclusion, patients with jailed side branches after stenting with XIENCE V compared to Taxus Express(2) devices had superior clinical outcomes at 2 years in the large-scale randomized SPIRIT IV trial. Copyright © 2013 Elsevier Inc. All rights reserved.
Hussein, Nabil; Qamar, Sombul; Abid, Qamar
2015-01-01
Aspergillus infections such as Aspergillus endocarditis were once relatively rare occurrences, however, due to the increased use of intracardiac devices, the incidence has grown. With mortality rates close to 100%, in medically treated cases, it is paramount that early diagnosis and treatment are performed. An immunocompetent aviculturist presented 8 months post aortic root replacement for severe aortic regurgitation with a composite graft, with central crushing chest pain. Investigations confirmed ST elevation inferior myocardial infarction due to stenosis of the origin of the right coronary artery, which was stented. Echocardiogram demonstrated a mobile mass posterior to the left ventricular outflow tract. Following referral to our cardiothoracic surgeons, a polypoidal mass covering the right ostial button was noted along with systemic complications of the disease. Emergency redo aortic valve replacement with a homograft and coronary artery bypass was performed. Histological analysis confirmed A. fumigatus and the patient was started on intravenous voriconazole. PMID:26025972
New stent design for use in small coronary arteries during percutaneous coronary intervention
Granada, Juan F; Huibregtse, Barbara A; Dawkins, Keith D
2010-01-01
Patients with diabetes mellitus, of female gender, increased age, and/or with peripheral vascular disease often develop coronary stenoses in small caliber vessels. This review describes treatment of these lesions with the paclitaxel-eluting 2.25 mm TAXUS® Liberté® Atom™ stent. Given the same stent composition, polymer, antirestenotic drug (paclitaxel), and release kinetics as the first-generation 2.25 mm TAXUS® Express® Atom™ stent, the second-generation TAXUS Liberté Atom stent incorporates improved stent design characteristics, including thinner struts (0.0038 versus 0.0052 inches), intended to increase conformability and deliverability. In a porcine noninjured coronary artery model, TAXUS Liberté Atom stent implantation in small vessels demonstrated complete strut tissue coverage compared with the bare metal stent control, suggesting a similar degree of tissue healing between the groups at 30, 90, and 180 days. The prospective, single-armed TAXUS ATLAS Small Vessel trial demonstrated improved instent late loss (0.28 ± 0.45 versus 0.84 ± 0.57 mm, P < 0.001), instent binary restenosis (13.0% versus 38.1%, P < 0.001), and target lesion revascularization (5.8% versus 17.6%, P < 0.001) at nine months with the TAXUS Liberté Atom stent as compared with the bare metal Express stent control, with similar safety measures between the two groups. The TAXUS Liberté Atom also significantly reduced nine-month angiographic rates of both instent late loss (0.28 ± 0.45 versus 0.44 ± 0.61 mm, P = 0.03) and instent binary restenosis (13.0% versus 25.9%, P = 0.02) when compared with the 2.25 mm TAXUS Express Atom control. The observed reduction in target lesion revascularization with the TAXUS Liberté Atom compared with the TAXUS Express Atom at nine months (5.8% versus 13.7%, P = 0.02) was sustained through three years (10.0% versus 22.1%, P = 0.008) with similar, stable safety outcomes between the groups. In conclusion, these data confirm the safety and favorable performance of the TAXUS Liberté Atom stent in the treatment of small coronary vessels. PMID:22915922
Recent perspective on coronary artery bifurcation interventions.
Dash, Debabrata
2014-01-01
Coronary bifurcation lesions are frequent in routine practice, accounting for 15-20% of all lesions undergoing percutaneous coronary intervention (PCI). PCI of this subset of lesions is technically challenging and historically has been associated with lower procedural success rates and worse clinical outcomes compared with non-bifurcation lesions. The introduction of drug-eluting stents has dramatically improved the outcomes. The provisional technique of implanting one stent in the main branch remains the default approach in most bifurcation lesions. Selection of the most effective technique for an individual bifurcation is important. The use of two-stent techniques as an intention to treat is an acceptable approach in some bifurcation lesions. However, a large amount of metal is generally left unapposed in the lumen with complex two-stent techniques, which is particularly concerning for the risk of stent thrombosis. New technology and dedicated bifurcation stents may overcome some of the limitations of two-stent techniques and revolutionise the management of bifurcation PCI in the future.
Everett, Kay D.; Conway, Claire; Desany, Gerard J.; Baker, Brian L.; Choi, Gilwoo; Taylor, Charles A.; Edelman, Elazer R.
2016-01-01
Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006–2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices. PMID:26467552
Everett, Kay D; Conway, Claire; Desany, Gerard J; Baker, Brian L; Choi, Gilwoo; Taylor, Charles A; Edelman, Elazer R
2016-02-01
Endovascular stents are the mainstay of interventional cardiovascular medicine. Technological advances have reduced biological and clinical complications but not mechanical failure. Stent strut fracture is increasingly recognized as of paramount clinical importance. Though consensus reigns that fractures can result from material fatigue, how fracture is induced and the mechanisms underlying its clinical sequelae remain ill-defined. In this study, strut fractures were identified in the prospectively maintained Food and Drug Administration's (FDA) Manufacturer and User Facility Device Experience Database (MAUDE), covering years 2006-2011, and differentiated based on specific coronary artery implantation site and device configuration. These data, and knowledge of the extent of dynamic arterial deformations obtained from patient CT images and published data, were used to define boundary conditions for 3D finite element models incorporating multimodal, multi-cycle deformation. The structural response for a range of stent designs and configurations was predicted by computational models and included estimation of maximum principal, minimum principal and equivalent plastic strains. Fatigue assessment was performed with Goodman diagrams and safe/unsafe regions defined for different stent designs. Von Mises stress and maximum principal strain increased with multimodal, fully reversed deformation. Spatial maps of unsafe locations corresponded to the identified locations of fracture in different coronary arteries in the clinical database. These findings, for the first time, provide insight into a potential link between patient adverse events and computational modeling of stent deformation. Understanding of the mechanical forces imposed under different implantation conditions may assist in rational design and optimal placement of these devices.
Conformability of balloon-expandable stents to the carotid siphon: an in vitro study.
du Mesnil de Rochemont, R; Yan, B; Zanella, F E; Rüfenacht, D A; Berkefeld, J
2006-02-01
Endovascular placement of coronary balloon-expandable stents in patients with recurrent cerebral ischemia has emerged as a treatment option for intracranial arterial occlusive disease. We have developed an in vitro model matching the tortuous curve of the carotid siphon that allows the assessment of apposition of stents to a curved vessel wall. Six types of balloon-expandable coronary stents were implanted in a silicone model of the carotid siphon. Digital radiographs and 3D rotational angiograms were obtained. Stent morphology was evaluated and the degree of apposition between stent and wall of the model was measured on a digital workstation. All 6 stents showed lack of apposition between stent and the wall at the convexity of the anterior segment of the carotid siphon and the wall at the concavity at both extremities of the stent. In and around the curve, the modules of the stents did not expand completely to their nominal diameter and were distorted to an oval shape. The tested coronary balloon-expandable stents did not completely conform to the vessel wall of the model of the carotid siphon and further development is needed to approach the goal of an "ideal intracranial stent."
Kurz, David J; Bernheim, Alain M; Tüller, David; Zbinden, Rainer; Jeger, Raban; Kaiser, Christoph; Galatius, Soeren; Hansen, Kim W; Alber, Hannes; Pfisterer, Matthias; Eberli, Franz R
2015-10-01
Drug-eluting stents (DES) improve outcomes in elderly patients with small coronary artery disease compared with bare-metal stents (BMS), but randomized data in elderly patients in need of large coronary stents are not available. Planned secondary analysis of patients ≥75 years recruited to the "BASKET-PROVE" trial, in which 2,314 patients undergoing percutaneous coronary intervention for large (≥3.0 mm) native vessel disease were randomized 2:1 to DES (everolimus- vs sirolimus-eluting stents 1:1) versus BMS. All patients received 12 months of dual antiplatelet therapy. The primary end point was a composite of cardiac death or nonfatal myocardial infarction at 2 years. Comparison of DES versus BMS among 405 patients ≥75 years showed significantly lower rates of the primary end point for DES (5.0% vs 11.6%; hazard ration (HR) 0.64 [0.44-0.91]; P = .014). Rates of nonfatal myocardial infarction (1.2% vs 5.5%, hazard ration (HR) 0.44 [0.21-0.83]; P = .009), all-cause death (7.4% vs 14.4%; HR 0.7 [0.51-0.95]; P = .02), and target vessel revascularization (TVR) (2.3% vs 6.2%; HR 0.59 [0.34-0.99]; P = .046) were also lower, whereas stent thrombosis and bleeding rates were similar. In contrast, among patients <75 years (n = 1,909), the only significant benefit of DES was a reduced rate of TVR (4.0% vs 8.7%, HR 0.66 [0.55-0.80]; P < .0001). In patients ≥75 years requiring large (≥3.0 mm) coronary stents, use of DES was beneficial compared with BMS and reduced the rate of ischemic events, mortality, and TVR. These data suggest that DES should be preferred over BMS in elderly patients. Copyright © 2015 Elsevier Inc. All rights reserved.
Wang, Xintong; Zachman, Angela L.; Chun, Young Wook; Shen, Fang-Wen; Hwang, Yu-Shik; Sung, Hak-Joon
2014-01-01
Background Biodegradable polymers have been applied as bulk or coating materials for coronary artery stents. The degradation of polymers, however, could induce endothelial dysfunction and aggravate neointimal formation. Here we use polymeric microparticles to simulate and demonstrate the effects of degraded stent materials on phagocytic activity, cell death and dysfunction of macrophages and endothelial cells. Methods Microparticles made of low molecular weight polyesters were incubated with human macrophages and coronary artery endothelial cells (ECs). Microparticle-induced phagocytosis, cytotoxicity, apoptosis, cytokine release and surface marker expression were determined by immunostaining or ELISA. Elastase expression was analyzed by ELISA and the elastase-mediated polymer degradation was assessed by mass spectrometry. Results We demonstrated poly(D,L-lactic acid) (PLLA) and polycaprolactone (PCL) microparticles induced cytotoxicity in macrophages and ECs, partially through cell apoptosis. The particle treatment alleviated EC phagocytosis, as opposed to macrophages, but enhanced the expression of vascular cell adhesion molecule-1 (VCAM) along with decreased nitric oxide production, indicating ECs were activated and lost their capacity to maintain homeostasis. The activation of both cell types induced release of elastase or elastase-like protease, which further accelerated polymer degradation. Conclusions This study revealed that low molecule weight PLLA and PCL microparticles increased cytotoxicity and dysregulated endothelial cell function, which in turn enhanced elastase release and polymer degradation. These indicate polymer or polymer-coated stents impose a risk of endothelial dysfunction after deployment which can potentially lead to delayed endothelialization, neointimal hyperplasia and late thrombosis. PMID:24820736
Huang, H; Zhou, Y; Shao, J; Cai, J; Mei, Y; Wang, Y
2012-12-01
The aim of this paper was to develop a new self-expandable aortic valved stent following the shape of the sinus of Valsalva, which can be deployed above native leaflets for aortic regurgitation, and study it's effect on coronary artery flow when orthotopic implantation in and above native leaflets. New self-expandable aortic valved stent consist of nitinol stent and bovine pericardium, and was designed following the shape of the sinus of Valsalva, the bovine pericardium was tailed as native leaflet. Thirty-six swine hearts were divided into three equal groups of twelve. In Group A (N.=12), the new self-expandable aortic valved stents deployed in native leaflets. In Group B (N.=12), the new self-expandable aortic valved stents deployed above native leaflets. In Group C (N.=12), the cylinder-like valved stents deployed only in native leaflets. The measurements of each coronary flow rate and endoscopic inspections were repeated post-implantation. In Group A and C, valve implantation in native leaflets resulted in a significant decrease in both left and right coronary flows. In Group B, no significant change in either right or left coronary flow was found after new self-expandable aortic valved stent placement. Endoscopic inspections showed that in group A and C the native leaflets sandwiched between valved stent and aortic wall, whereas, in group B the native leaflets were under the artificial leaflets. Two kinds of stents deployed in native leaflets affect left and right coronary flows significantly. No significant effect was found when the new self-expandable aortic valved stent deployed above native leaflets. This new self-expandable aortic valved stent can be deployed above the native leaflets, which avoids the obstruction of native leaflets on coronary flow.
Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Alexandru, Dragos; Meraj, Perwaiz; Shlofmitz, Richard
2016-08-01
We evaluated the safety and efficacy of orbital atherectomy in real-world patients with severe coronary artery calcification (CAC). The presence of severe CAC increases the complexity of percutaneous coronary intervention as it may impede stent delivery and optimal stent expansion. Atherectomy may be an indispensable tool for uncrossable or undilatable lesions by modifying severe CAC. Although the ORBIT I and II trials report that orbital atherectomy was safe and effective for the treatment of severe CAC, patients with kidney disease, recent myocardial infarction, long diffuse disease, severe left ventricular dysfunction, and unprotected left main disease were excluded. This retrospective study included 458 consecutive patients with severe CAC who underwent orbital atherectomy followed by stenting from October 2013 to December 2015 at 3 centers. The primary endpoint of major adverse cardiac and cerebrovascular events at 30 days was 1.7%. Low rates of 30-day all-cause mortality (1.3%), myocardial infarction (1.1%), target vessel revascularization (0%), stroke (0.2%), and stent thrombosis (0.9%) were observed. Angiographic complications were low: perforation was 0.7%, dissection 0.9%, and no-reflow 0.7%. Emergency coronary artery bypass graft surgery was performed in 0.2% of patients. In the largest real-world study of patients who underwent orbital atherectomy, including high-risk patients who were not surgical candidates as well as those with very complex coronary anatomy, acute and short-term adverse clinical event rates were low. A randomized clinical trial is needed to identify the ideal treatment strategy for patients with severe CAC. © 2016 The Authors. Journal of Interventional Cardiology Published by Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiyosue, Hiro, E-mail: hkiyosue@oita-med.ac.jp; Okahara, Mika; Yamashita, Masanori
Percutaneous transluminal balloon angioplasty (PTA) has been used in the treatment of critical stenosis of the intracranial vertebrobasilar artery (VBA). PTA of the intracranial VBA carries the risk of fatal complications such as arterial dissection or acute occlusion as well as postoperative restenosis. The estimated risk of periprocedural complications and restenosis were approximately 20% and 27%. The use of recently developed stents could prevent these problems of PTA. We present two cases of restenosis of the intracranial VBA after PTA which stenoses were successfully retreated with endovascular stenting using flexible coronary stents without any complications. Neither restenosis nor other recurrentmore » symptoms were observed during the 4- and 6-month follow-up period. Reviewing the literature of 33 cases and our 2 cases, the overall complication rates related to stenting and restenosis were 5.6% and 7.8%. Endovascular stenting for the treatment of intracranial VBA can reduce the risk of arterial dissection and restenosis.« less
NASA Astrophysics Data System (ADS)
Schäfer, Dirk; Movassaghi, Babak; Grass, Michael; Schoonenberg, Gert; Florent, Raoul; Wink, Onno; Klein, Andrew J. P.; Chen, James Y.; Garcia, Joel; Messenger, John C.; Carroll, John D.
2007-03-01
The complete expansion of the stent during a percutaneous transluminal coronary angioplasty (PTCA) procedure is essential for treatment of a stenotic segment of a coronary artery. Inadequate expansion of the stent is a major predisposing factor to in-stent restenosis and acute thrombosis. Stents are positioned and deployed by fluoroscopic guidance. Although the current generation of stents are made of materials with some degree of radio-opacity to detect their location after deployment, proper stent expansion is hard to asses. In this work, we introduce a new method for the three-dimensional (3D) reconstruction of the coronary stents in-vivo utilizing two-dimensional projection images acquired during rotational angiography (RA). The acquisition protocol consist of a propeller rotation of the X-ray C-arm system of 180°, which ensures sufficient angular coverage for volume reconstruction. The angiographic projections were acquired at 30 frames per second resulting in 180 projections during a 7 second rotational run. The motion of the stent is estimated from the automatically tracked 2D coordinates of the markers on the balloon catheter. This information is used within a motion-compensated reconstruction algorithm. Therefore, projections from different cardiac phases and motion states can be used, resulting in improved signal-to-noise ratio of the stent. Results of 3D reconstructed coronary stents in vivo, with high spatial resolution are presented. The proposed method allows for a comprehensive and unique quantitative 3D assessment of stent expansion that rivals current X-ray and intravascular ultrasound techniques.
Sveshnikova, N D; Paleev, F N
2016-03-01
Assessment of cost of management of patients during 1 year after stenting of coronary arteries has shown that priority should be given to active introduction into practical health care of technologies increasing duration of life and lowering probability of invalidization. We stress the need for evaluation of indirect expenditures on patients care because of their substantial share in the total cost. We also consider essential to elaborate measures of state regulation of medication supply irrespective of type of treatment for shifting expenditures from hospital to ambulatory sector and improvement of effectiveness of pharmacotherapy.
Deora, Surender; Shah, Sanjay C; Patel, Tejas M
2015-01-01
Percutaneous coronary interventions (PCIs) of saphenous vein grafts (SVGs) is challenging and is associated with adverse short- and long-term clinical outcome as compared to native coronary arteries. SVG perforation is rare but catastrophic and needs immediate attention. Various factors predisposing for SVG perforation are old degenerated graft, ulcerated plaque, severe fibrotic, or calcified lesion necessitating high pressure balloon or stent inflation, use of intravascular ultrasound (IVUS) or other atheroablative devices. Management includes prolonged balloon occlusion, reversal of anticoagulation, use of covered stent, and emergency pericadiocentesis if required.
Stenting of the ascending aorta revisited.
Moiduddin, Nasser J; Rios, Rodrigo; El-Said, Howaida; Moore, John W
2017-10-01
Despite few institutions stenting the ascending aorta, it has been discouraged because of the proximity of the aortic valve, the coronary artery orifices, and the aortic arch branches. We describe a small case series of patients having acquired stenosis of the ascending that was relieved successfully by stenting. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Code of Federal Regulations, 2012 CFR
2012-10-01
... rehabilitation treatment, and psychosocial evaluation of the individual's response to and rate of progress under... coronary artery bypass surgery; (iii) Current stable angina pectoris; (iv) Heart valve repair or replacement; (v) Percutaneous transluminal coronary angioplasty (PTCA) or coronary stenting; (vi) A heart or...
Code of Federal Regulations, 2013 CFR
2013-10-01
... rehabilitation treatment, and psychosocial evaluation of the individual's response to and rate of progress under... coronary artery bypass surgery; (iii) Current stable angina pectoris; (iv) Heart valve repair or replacement; (v) Percutaneous transluminal coronary angioplasty (PTCA) or coronary stenting; (vi) A heart or...
Code of Federal Regulations, 2014 CFR
2014-10-01
... rehabilitation treatment, and psychosocial evaluation of the individual's response to and rate of progress under... coronary artery bypass surgery; (iii) Current stable angina pectoris; (iv) Heart valve repair or replacement; (v) Percutaneous transluminal coronary angioplasty (PTCA) or coronary stenting; (vi) A heart or...
NASA Astrophysics Data System (ADS)
Widiyanti, Prihartini; Paramadini, Adanti W.; Jabbar, Hajria; Fatimah, Inas; Nisak, Fadila N. K.; Puspitasari, Rahma A.
2016-03-01
Cardiovascular disease is a global disease with high urgency. In the severe case of coronary heart disease while a blockage in the coronary arteries reach 75% or more, the patient required stent implantation. Stents are made of metal which has many limitations that can lead to blood clots and stent incompatibility toward the size of the blood vessels. There is a metal stent replacement solution that made from polymer material which is biocompatible. PLLA also has biocompatibility and good mechanical strength. PLLA stent will be coated with chitosan as a candidate for drug-coated stents which is able to work as a drug carrier. The aim of this study is to know the morphology information and biocompability status of PLLA coating chitosan as candidate of heart stent. Morphological results using SEM showed a smooth surface structure which reinforced clinical standard of stent material. Results of cytotoxicity test by MTT Assay method showed that the result of four samples in this experiment living cells is reached 90% which is non toxic and safe to use in the human body. %). The conclusion of this study is PLLA is polymer has potency to be used as stent material.
Granada, Juan F; Tellez, Armando; Baumbach, William R; Bingham, Brendan; Keng, Yen-Fang; Wessler, Jeffrey; Conditt, Gerard; McGregor, Jennifer; Stone, Gregg; Kaluza, Greg L; Leon, Martin B
2016-08-20
Among antirestenotic compounds, sirolimus displays a superior safety profile compared to paclitaxel, but its pharmacokinetic properties make it a challenging therapeutic candidate for single-time delivery. Herein we evaluate the feasibility of delivery, long-term retention and vascular effects of sirolimus nanoparticles delivered through a novel porous angioplasty balloon in normal porcine arteries and in a swine model of in-stent restenosis (ISR). Sirolimus nanoparticle formulation was delivered via porous balloon angioplasty to 753 coronary artery segments for pharmacokinetic studies and 26 segments for biological effect of sirolimus delivery in different clinical scenarios (de novo [n=8], ISR [n=6] and following stent implantation [n=12]). Sirolimus coronary artery concentrations were above the target therapeutic level of 1 ng/mg after 26 days, and were >100-fold higher in coronary artery treatment sites than in distal myocardium and remote tissues at all time points. At 28 days, reduction in percent stenosis in formulation-treated sites compared to balloon angioplasty treatment was noted in all three clinical scenarios, with the largest effect seen in the de novo study. Local coronary delivery of sirolimus nanoparticles in the porcine model using a novel porous balloon delivery system achieved therapeutic long-term intra-arterial drug levels without significant systemic residual exposure.
Jeong, Young-Hoon; Koh, Jin-Sin; Kang, Min-Kyung; Ahn, Yeon-Jeong; Kim, In-Suk; Park, Yongwhi; Hwang, Seok-Jae; Kwak, Choong Hwan; Hwang, Jin-Yong
2010-06-01
In patients with coronary artery stents, the cost of clopidogrel has been cited as a factor in the premature discontinuation of therapy. Thus, the introduction of lower-cost generic clopidogrel may increase patient compliance. However, platelet inhibition by generic clopidogrel has not been compared to the original clopidogrel formulation in patients with coronary artery stents. We prospectively enrolled 20 patients receiving chronic therapy with the original clopidogrel bisulfate (Plavix). After assessing patient compliance with Plavix, maintenance therapy was switched to generic clopidogrel bisulfate (Plavitor). Platelet reactivity was assessed at baseline and 30-day after the switch using conventional aggregometry and the VerifyNow P2Y12 assay. All patients completed maintenance therapy with Plavitor. Before and after switching therapy maximal (36.5 +/- 7.9% vs. 39.8 +/- 16.2%, p = 0.280) and late platelet aggregation (23.5 +/- 10.9% vs. 29.1 +/- 18.3%, p = 0.156) with 5 micromol/L adenosine diphosphate (ADP) stimulus did not differ. Likewise, 20 micromol/L ADP-induced platelet aggregation and P2Y12 reaction unit in patients on Plavitor therapy was comparable to that in patients on Plavix therapy. However, Bland-Altman analysis showed wide limits of agreement between measured platelet reactivity on Plavix vs. Plavitor therapies. Among patients on Plavix maintenance therapy with coronary stents, replacement with Plavitor shows a comparable inhibition of ADP-induced platelet aggregation. However, due to poor inter-therapy agreement, between two regimens, physicians may be cautious when introducing generic clopidogrel bisulfate.
[Brief history of percutaneous coronary intervention].
Song, Zhi-yuan; Zhang, Zhi-ying; Xu, Ze-sheng
2010-05-01
Percutaneous coronary intervention (PCI) is that delivering balloon catheter and/or equipment such as a stent to the target coronary artery bypass peripheral artery, at the same time, expanding and opening the stenosis of coronary artery. Through several decades of development, PCI has become a most effective way to rescue patients with coronary heart disease and become one of the biggest advances in the field of heart disease. Because of the development of PCI, more lives have been saved in patients with coronary heart disease. However, PCI does not meet the point of perfection, still has a lot of issues remain to be further resolved. Through a review the development of PCI, we may be able to get some insights to perfect the treatment technique for the patients of coronary heart disease.
Chandra, Praveen; Kumar, Tarun
2014-01-01
A prospective, multicenter, post marketing surveillance study to evaluate the safety and effectiveness of the Superia-Sirolimus Eluting Coronary Stent System (SSECSS) implanted during routine clinical practice in India. 1. To study the MACE and in stent and In-segment Loss at Six Months (in a pre selected group of 50 patients). 1. Clinical and procedural success. This is a prospective, open label, single-arm, multicenter (16 sites), post marketing observational study enrolling patients implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) in routine clinical practice in India. A total of 200 Patients of coronary Artery Disease (CAD) implanted with Superia-Sirolimus Eluting Coronary Stent (SSECS) were enrolled. Clinical assessments were done at 30 days, 180 days and at 1, 2 years either telephonically or office visit. A cohort of 50 pre-selected patients were followed up for angiographic evaluation at 180 days. MACE at 12 month of follow up was 1.71%.Late lumen loss, in segment was 0.14 and in stent was 0.10 mm at 6 month of follow-up. TLR was required only in 2 patients. Superia stent is as safe as other biodegradable polymer stent in the market and time has come for biodegradable polymer stent with thin struts. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Seth, Ashok; Hiremath, Shirish; Dani, Sameer; Kapoor, Sunil; Jain, R K; Abhaichand, Rajpal; Trivedi, Shailendra; Kaul, Upendra; Patil, Aruna; Khemnar, Bhushan; Rangnekar, Hrishikesh
2013-01-01
The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India. Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non diabetics and remains an independent risk factor of restenosis, need for revascularization, and overall mortality. Stent thrombosis is a potential complication of first generation, permanent polymer drug-eluting stents. Biodegradable polymer is a good relief in this era and its utility in diabetic patients will be a major advantage for them. 334 patients with diabetes mellitus and requiring angioplasty, implanted with BioMatrix stent were followed at 1, 6, 12 and 24 months who entered in a multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, 12 and 24 months. The mean age was 58.71 ± 9.2 years, 81% were males, comorbidity index was 1.6 ± 1.02, and 59.1% presented with acute coronary syndrome. The incidence of adverse event rates was: MACE 1.27%. There were no incidences of myocardial infarction (MI) and target vessel revascularization (TVR). Definite stent thrombosis occurred only in 2 patients. In this registry of diabetic population treated with BioMatrixTM-Biolimus A9TM eluting stent (BioMatrix), the reported incidence of MACE and ST were much lower than previously published results. The 1- and 2-year follow-up result supports favorable clinical outcomes of using BioMatrix stents as a suitable alternative to contemporary DES available during PCI in diabetic patients. Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Seth, Ashok; Hiremath, Shirish; Dani, Sameer; Kapoor, Sunil; Jain, R.K.; Abhaichand, Rajpal; Trivedi, Shailendra; Kaul, Upendra; Patil, Aruna; Khemnar, Bhushan; Rangnekar, Hrishikesh
2013-01-01
Objective The objective of this registry is to establish safety and efficacy of BioMatrix, BioMatrix™-Biolimus A9™ eluting stent in diabetic population in India. Background Diabetes mellitus is a major predisposing factor for coronary artery disease. Prognosis for diabetic population patients presenting with coronary artery disease who undergo coronary revascularization is inferior to non diabetics and remains an independent risk factor of restenosis, need for revascularization, and overall mortality. Stent thrombosis is a potential complication of first generation, permanent polymer drug-eluting stents. Biodegradable polymer is a good relief in this era and its utility in diabetic patients will be a major advantage for them. Methods 334 patients with diabetes mellitus and requiring angioplasty, implanted with BioMatrix stent were followed at 1, 6, 12 and 24 months who entered in a multicenter registry in India. We analyzed the incidence of major adverse cardiac events (MACE) and stent thrombosis (ST) at 1, 6, 12 and 24 months. Results The mean age was 58.71 ± 9.2 years, 81% were males, comorbidity index was 1.6 ± 1.02, and 59.1% presented with acute coronary syndrome. The incidence of adverse event rates was: MACE 1.27%. There were no incidences of myocardial infarction (MI) and target vessel revascularization (TVR). Definite stent thrombosis occurred only in 2 patients. Conclusion In this registry of diabetic population treated with BioMatrixTM-Biolimus A9TM eluting stent (BioMatrix), the reported incidence of MACE and ST were much lower than previously published results. The 1- and 2-year follow-up result supports favorable clinical outcomes of using BioMatrix stents as a suitable alternative to contemporary DES available during PCI in diabetic patients. PMID:24206882
Di Santo, Pietro; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Harnett, David T; Singh, Kuljit; Moreland, Robert; Chong, Aun-Yeong; Dick, Alexander; Labinaz, Marino; Froeschl, Michael; Froeschl, Michael; Le May, Michael R; So, Derek Y; Hibbert, Benjamin
2015-10-07
Percutaneous coronary intervention is the most commonly performed method of revascularizing obstructive coronary artery disease. The impact of stent strut design on clinical outcomes remains unclear. The Endeavour Resolute (ER-ZES) and the Resolute Integrity (RI-ZES) zotarolimus-eluting stents utilize identical polymers and anti-proliferative agents, differing only in their respective strut design. This study assessed the comparative safety and efficacy of these two stents in unrestricted contemporary real-world practice. A total of 542 patients were identified, corresponding to 340 ER-ZES and 480 RI-ZES. The primary endpoint was major adverse cardiac events (MACE) defined by a composite of death, nonfatal myocardial infarction and stroke. Secondary endpoints included post-procedural length of stay, in-stent restenosis, target lesion revascularization, target vessel revascularization, coronary artery bypass grafting and stent thrombosis. MACE occurred in 3.2% of the ER-ZES cohort and 5.0% of the RI-ZES cohort (p= 0.43). Adjusted analysis utilizing propensity score-adjusted odds ratio for MACE, was 1.37 (95% CI 0.46-4.07, p=0.57). The mortality rate (0.9% ER-ZES vs. 1.9% RI-ZES, p=0.59), non-fatal MI (2.3% ER-ZES vs. 3.1% RI-ZES, p=0.75) and stroke (0.0% ER-ZES vs. 0.3% RI-ZES, p=0.85) were not different. Additionally, there was no difference in any of secondary outcomes. The clinical performance and safety of both ER-ZES and RI-ZES were not statistically different, despite differences in stent strut design.
The current role of vascular stents.
Busquet, J
1993-09-01
The limitations of percutaneous balloon angioplasty have favoured the development and the use of vascular endoprostheses or stents. These thin-walled metal devices maintain after expansion, an optimal and constant diameter for the vascular lumen. Restenosis, dissection, abrupt closure, residual stenosis or re-opened total occlusion represent appropriate indications for stenting. A large experience with non-coronary application of stents is currently available in iliac, femoro-popliteal and renal arteries, aorta, large veins.
Valuckiene, Zivile; Neuser, Hans; Walter, Marlon; Gappmaier, Wolfgang; Kaiser, Thomas; Neumann, Franz-Josef; Akin, Ibrahim; Behnes, Michael
2016-01-01
This case report describes a successful percutaneous coronary intervention (PCI) of a severely calcified aorto-ostial chronic total occlusion (CTO) of the right coronary artery (RCA). The lesion was treated by a retrograde approach implementing long spiral subintimal wire tracking and final coronary stenting creating a subintimal neo-luminal helix around the natively occluded RCA. After 6 months of follow-up valuable angiographic results were proven. PMID:28066662
Acute Iliac Artery Rupture: Endovascular Treatment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chatziioannou, A.; Mourikis, D.; Katsimilis, J.
The authors present 7 patients who suffered iliac artery rupture over a 2 year period. In 5 patients, the rupture was iatrogenic: 4 cases were secondary to balloon angioplasty for iliac artery stenosis and 1 occurred during coronary angioplasty. In the last 2 patients, the rupture was secondary to iliac artery mycotic aneurysm. Direct placement of a stent-graft was performed in all cases, which was dilated until extravasation was controlled. Placement of the stent-graft was successful in all the cases, without any complications. The techniques used, results, and mid-term follow-up are presented. In conclusion, endovascular placement of a stent-graft ismore » a quick, minimally invasive, efficient, and safe method for emergency treatment of acute iliac artery rupture, with satisfactory short- and mid-term results.« less
Percutaneous Coronary Intervention for a Patient with Left Main Coronary Compression Syndrome.
Ikegami, Ryutaro; Ozaki, Kazuyuki; Ozawa, Takuya; Hirono, Satoru; Ito, Masahiro; Minamino, Tohru
2018-05-15
Left main coronary compression syndrome rarely occurs in patients with severe pulmonary hypertension. A 65-year-old woman with severe pulmonary hypertension due to an atrial septal defect suffered from angina on effort. Cardiac computed-tomography and coronary angiography revealed considerable stenosis of the left main coronary artery (LMA) caused by compression between the dilated main pulmonary artery trunk and the sinus of valsalva. Stenting of the LMA under intravascular ultrasound imaging was effective for the treatment of angina. We herein report the diagnosis and management of this condition with a brief literature review.
Vassalli, Giuseppe; Klersy, Catherine; De Servi, Stefano; Galatius, Soeren; Erne, Paul; Eberli, Franz; Rickli, Hans; Hornig, Burkhard; Bertel, Osmund; Bonetti, Piero; Moccetti, Tiziano; Kaiser, Christoph; Pfisterer, Matthias; Pedrazzini, Giovanni
2016-03-01
The randomized BASKET-PROVE study showed no significant differences between sirolimus-eluting stents (SES), everolimus-eluting stents (EES), and bare-metal stents (BMS) with respect to the primary end point, rates of death from cardiac causes, or myocardial infarction (MI) at 2 years of follow-up, in patients requiring stenting of a large coronary artery. Clinical risk factors may affect clinical outcomes after percutaneous coronary interventions. We present a retrospective analysis of the BASKET-PROVE data addressing the question as to whether the optimal type of stent can be predicted based on a cumulative clinical risk score. A total of 2,314 patients (mean age 66 years) who underwent coronary angioplasty and implantation of ≥1 stents that were ≥3.0 mm in diameter were randomly assigned to receive SES, EES, or BMS. A cumulative clinical risk score was derived using a Cox model that included age, gender, cardiovascular risk factors (hypercholesterolemia, hypertension, family history of cardiovascular disease, diabetes, smoking), presence of ≥2 comorbidities (stroke, peripheral artery disease, chronic kidney disease, chronic rheumatic disease), a history of MI or coronary revascularization, and clinical presentation (stable angina, unstable angina, ST-segment elevation MI). An aggregate drug-eluting stent (DES) group (n = 1,549) comprising 775 patients receiving SES and 774 patients receiving EES was compared to 765 patients receiving BMS. Rates of death from cardiac causes or nonfatal MI at 2 years of follow-up were significantly increased in patients who were in the high tertile of risk stratification for the clinical risk score compared to those who were in the aggregate low-mid tertiles. In patients with a high clinical risk score, rates of death from cardiac causes or nonfatal MI were lower in patients receiving DES (2.4 per 100 person-years, 95% CI 1.6-3.6) compared with BMS (5.5 per 100 person-years, 95% CI 3.7-8.2, hazard ratio 0.45, 95% CI 0.26-0.80, P = .007). However, they were not significantly different between receivers of DES and BMS in patients in the low-mid risk tertiles. This exploratory analysis suggests that, in patients who require stenting of a large coronary artery, use of a clinical risk score may identify those patients for whom DES use may confer a clinical advantage over BMS, beyond lower restenosis rates. Copyright © 2015 Elsevier Inc. All rights reserved.
Recurrent syncope attributed to left main coronary artery severe stenosis.
Li, Min; Zheng, Xinyi; Liu, Hua; Liu, Yujie
2015-01-01
Patients with acute coronary syndrome (ACS) rarely manifest as recurrent syncope due to malignant ventricular arrhythmia. We report a case of a 56-year-old Chinese male with complaints of paroxysmal chest burning sensation and distress for 2 weeks as well as loss of consciousness for 3 days. The electrocardiogram (ECG) revealed paroxysmal multimorphologic ventricular tachycardia during attack and normal heart rhythm during intervals. Coronary angiograph showed 90% stenosis in left main coronary artery and 80% stenosis in anterior descending artery. Two stents sized 4.0∗18 mm and 2.75∗18 mm were placed at left main coronary artery and anterior descending artery, respectively, during percutaneous coronary intervention (PCI). The patient was discharged and never had ventricular arrhythmia again during a 3-month follow-up since the PCI. This indicated that ventricular tachycardia was correlated with persistent severe myocardial ischemia. Coronary vasospasm was highly suspected to be the reason of the sudden attack and acute exacerbation. PCI is recommended in patients with both severe coronary artery stenosis and ventricular arrhythmia. Removing myocardial ischemia may stop or relieve ventricular arrhythmia and prevent cardiac arrest.
Figini, Filippo; Manjunath, Chaman Nadish; Srinivas, Balaji Chandra; Sadananda, Kanvar Sarat; Sreedharan, Madhu; Fischer, Louie; Pillai, Ramakrishna; Varghese, Kiron; Gopal, Ajay K; Nagesh, Chamarajnagar Mahadevappa; Sheiban, Imad
2017-10-07
To report long-term results of a novel sirolimus-eluting stent with biodegradable polymer BACKGROUND: Newer generation drug-eluting stents are characterized by thin struts, improved platform design and highly biocompatible polymer carrying the antiproliferative drug. The RapstromTM stent, sharing these features, showed promising outcomes in preclinical models and in a first-in-man trial. The present study is a multicenter, non-randomized post-market registry, including patients with de novo coronary artery disease treated with implantation of one or more Rapstrom stents. Primary endpoint of the study was the rate of major adverse cardiac events (MACE) at three-year follow-up. 1073 patients were enrolled, with a high prevalence of diabetes (35%) and acute coronary syndrome at presentation (82%); at three-year follow up, MACE rate was 14.8%, with a low incidence of definite or probable stent thrombosis (0.75%). These data confirm the good clinical performance of the Rapstrom stent, supporting the concept that the combination of thin struts and biodegradable polymer is associated with positive clinical outcomes. Copyright © 2017 Elsevier Inc. All rights reserved.
Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease.
Stone, Gregg W; Sabik, Joseph F; Serruys, Patrick W; Simonton, Charles A; Généreux, Philippe; Puskas, John; Kandzari, David E; Morice, Marie-Claude; Lembo, Nicholas; Brown, W Morris; Taggart, David P; Banning, Adrian; Merkely, Béla; Horkay, Ferenc; Boonstra, Piet W; van Boven, Ad J; Ungi, Imre; Bogáts, Gabor; Mansour, Samer; Noiseux, Nicolas; Sabaté, Manel; Pomar, José; Hickey, Mark; Gershlick, Anthony; Buszman, Pawel; Bochenek, Andrzej; Schampaert, Erick; Pagé, Pierre; Dressler, Ovidiu; Kosmidou, Ioanna; Mehran, Roxana; Pocock, Stuart J; Kappetein, A Pieter
2016-12-08
Patients with obstructive left main coronary artery disease are usually treated with coronary-artery bypass grafting (CABG). Randomized trials have suggested that drug-eluting stents may be an acceptable alternative to CABG in selected patients with left main coronary disease. We randomly assigned 1905 eligible patients with left main coronary artery disease of low or intermediate anatomical complexity to undergo either percutaneous coronary intervention (PCI) with fluoropolymer-based cobalt-chromium everolimus-eluting stents (PCI group, 948 patients) or CABG (CABG group, 957 patients). Anatomic complexity was assessed at the sites and defined by a Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery (SYNTAX) score of 32 or lower (the SYNTAX score reflects a comprehensive angiographic assessment of the coronary vasculature, with 0 as the lowest score and higher scores [no upper limit] indicating more complex coronary anatomy). The primary end point was the rate of a composite of death from any cause, stroke, or myocardial infarction at 3 years, and the trial was powered for noninferiority testing of the primary end point (noninferiority margin, 4.2 percentage points). Major secondary end points included the rate of a composite of death from any cause, stroke, or myocardial infarction at 30 days and the rate of a composite of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years. Event rates were based on Kaplan-Meier estimates in time-to-first-event analyses. At 3 years, a primary end-point event had occurred in 15.4% of the patients in the PCI group and in 14.7% of the patients in the CABG group (difference, 0.7 percentage points; upper 97.5% confidence limit, 4.0 percentage points; P=0.02 for noninferiority; hazard ratio, 1.00; 95% confidence interval, 0.79 to 1.26; P=0.98 for superiority). The secondary end-point event of death, stroke, or myocardial infarction at 30 days occurred in 4.9% of the patients in the PCI group and in 7.9% in the CABG group (P<0.001 for noninferiority, P=0.008 for superiority). The secondary end-point event of death, stroke, myocardial infarction, or ischemia-driven revascularization at 3 years occurred in 23.1% of the patients in the PCI group and in 19.1% in the CABG group (P=0.01 for noninferiority, P=0.10 for superiority). In patients with left main coronary artery disease and low or intermediate SYNTAX scores by site assessment, PCI with everolimus-eluting stents was noninferior to CABG with respect to the rate of the composite end point of death, stroke, or myocardial infarction at 3 years. (Funded by Abbott Vascular; EXCEL ClinicalTrials.gov number, NCT01205776 .).
Kawashiri, Masa-aki; Sakata, Kenji; Uchiyama, Katsuharru; Konno, Tetsuo; Namura, Masanobu; Mizuno, Sumio; Tatami, Ryozo; Kanaya, Honin; Nitta, Yutaka; Michishita, Ichiro; Hirase, Hiroaki; Ueda, Kosei; Aoyama, Takashi; Okeie, Kazuyasu; Haraki, Tatsuo; Mori, Kiyoo; Araki, Tsutomu; Minamoto, Masaharu; Oiwake, Hisanori; Ino, Hidekazu; Hayashi, Kenshi; Yamagishi, Masakazu
2014-04-01
Whether the lesion morphology and associated interventional procedures for the left main coronary artery disease (LMCA) could affect clinical outcome is still controversial. Therefore, we examined the impact of lesion morphology and associated procedures on clinical and angiographic outcomes of stenting for the LMCA. Among 7,660 patients with coronary intervention registered, we analyzed early angiographic results of 228 patients (179 men, mean age 69.4 years) concerned with LMCA lesions. In 121 out of 228 patients having long-term angiographic results, we examined the occurrence of major adverse coronary events (MACE) particularly in terms of the presence of acute coronary syndrome (ACS), the kind of stents, bear metal or drug eluting, the lesion morphology and associated procedures. Early angiographic success rate of LMCA stenting was 100 %, and clinical success rate was 94.3 %. During follow-up period for 3 years, MACE was observed in 17 patients. Under these conditions, multiple stenting (p < 0.01) and complicated procedures such as such as Y-stent, T-stent and crush stent (p < 0.01) were listed as risks for MACE, although there was no statistical difference in kinds of stent. Multivariate analysis demonstrated the significant disadvantage of complicated procedures using the bear metal stent on the occurrence of MACE (p < 0.01). These results demonstrate that the complicated procedures have great impact on clinical and angiographic outcomes after stenting for LMCA lesions, and suggest the simple procedure with a single stent for LMCA lesions in the present cohort. Whether the presence of ACS can affect the prognosis should further be sought.
Cost effectiveness of drug eluting coronary artery stenting in a UK setting: cost-utility study.
Bagust, A; Grayson, A D; Palmer, N D; Perry, R A; Walley, T
2006-01-01
To assess the cost effectiveness of drug eluting stents (DES) compared with conventional stents for treatment of symptomatic coronary artery disease in the UK. Cost-utility analysis of audit based patient subgroups by means of a simple economic model. Tertiary care. 12 month audit data for 2884 patients receiving percutaneous coronary intervention with stenting at the Cardiothoracic Centre Liverpool between January 2000 and December 2002. Risk of repeat revascularisation within 12 months of index procedure and reduction in risk from use of DES. Economic modelling was used to estimate the cost-utility ratio and threshold price premium. Four factors were identified for patients undergoing elective surgery (n = 1951) and two for non-elective surgery (n = 933) to predict risk of repeat revascularisation within 12 months. Most patients fell within the subgroup with lowest risk (57% of the elective surgery group with 5.6% risk and 91% of the non-elective surgery group with 9.9% risk). Modelled cost-utility ratios were acceptable for only one group of high risk patients undergoing non-elective surgery (only one patient in audit data). Restricting the number of DES for each patient improved results marginally: 4% of stents could then be drug eluting on economic grounds. The threshold price premium justifying 90% substitution of conventional stents was estimated to be 112 pound sterling (212 USD, 162 pound sterling) (sirolimus stents) or 89 pound sterling (167 USD, 130 pound sterling) (paclitaxel stents). At current UK prices, DES are not cost effective compared with conventional stents except for a small minority of patients. Although the technology is clearly effective, general substitution is not justified unless the price premium falls substantially.
Habib, Robert H.; Dimitrova, Kamellia R.; Badour, Sanaa A.; Yammine, Maroun B.; El-Hage-Sleiman, Abdul-Karim M.; Hoffman, Darryl M.; Geller, Charles M.; Schwann, Thomas A.; Tranbaugh, Robert F.
2017-01-01
BACKGROUND Treatment of multivessel coronary artery disease with traditional single-arterial coronary artery bypass graft (SA-CABG) has been associated with superior intermediate-term survival and reintervention compared with percutaneous coronary intervention (PCI) using either bare-metal stents (BMS) or drug-eluting stents (DES). OBJECTIVES This study sought to investigate longer-term outcomes including the potential added advantage of multiarterial coronary artery bypass graft (MA-CABG). METHODS We studied 8,402 single-institution, primary revascularization, multivessel coronary artery disease patients: 2,207 BMS-PCI (age 66.6 ± 11.9 years); 2,381 DES-PCI (age 65.9 ± 11.7 years); 2,289 SA-CABG (age 69.3 ± 9.0 years); and 1,525 MA-CABG (age 58.3 ± 8.7 years). Patients with myocardial infarction within 24 h, shock, or left main stents were excluded. Kaplan-Meier analysis and Cox regression were used to separately compare 9-year all-cause mortality and unplanned reintervention for BMS-PCI and DES-PCI to respective propensity-matched SA-CABG and MA-CABG cohorts. RESULTS BMS-PCI was associated with worse survival than SA-CABG, especially from 0 to 7 years (p = 0.015) and to a greater extent than MA-CABG was (9-year follow-up: 76.3% vs. 86.9%; p < 0.001). The surgery-to-BMS-PCI hazard ratios (HR) were as follows: versus SA-CABG, HR: 0.87; and versus MA-CABG, HR: 0.38. DES-PCI showed similar survival to SA-CABG except for a modest 0 to 3 years surgery advantage (HR: 1.06; p = 0.615). Compared with MA-CABG, DES-PCI exhibited worse survival at 5 (86.3% vs. 95.6%) and 9 (82.8% vs. 89.8%) years (HR: 0.45; p <0.001). Reintervention was substantially worse with PCI for all comparisons (all p <0.001). CONCLUSIONS Multiarterial surgical revascularization, compared with either BMS-PCI or DES-PCI, resulted in substantially enhanced death and reintervention-free survival. Accordingly, MA-CABG represents the optimal therapy for multivessel coronary artery disease and should be enthusiastically adopted by multidisciplinary heart teams as the best evidence-based therapy. PMID:26403338
Zhao, Jun-Li; Sun, Bao-Gui; Wen, Qin-Zhu
2010-06-01
To study the safety and efficacy of control-releasing arsenic trioxide (As2O3)-eluting stent on intimal smooth muscle cells (SMC) and type III collagen (CIII) in canine coronary artery post-stent model. Twenty-four experimental canines were equally divided into 4 groups, the three tested groups were deployed by stents with different dosage of As2O3 (1.6 microg/mm2, 2.4 microg/mm2 and 3.2 microg/mm2 in low, median and high dose groups, respectively) and coated with polybutyl methacrylate/nano silica and poly-lactide-coglycolide in mild oversizing (stent/vessel ratio of 1.3:1) in left anterior descending (LAD) or circumflex coronary arteries (LCX), while the control group only by simple coated stent without As2O3. The effect was assessed 4 weeks after stent implantation in terms of vascular histomorphology, and changes of SMC and C III expressions were detected using immunohistochemical analysis. Subintimal hemorrhage, medial/adventitial necrosis, thrombosis and inflammatory cell infiltration were not found and integral endothelium could be seen under screening electron microscopy in all groups. Positive expression of SMC and CIII in the tested groups, especial in the high dose As2O3 group, was more weaker than that in control group. Histo-morphological analysis showed that the neo-genetic intimal area and vascular stenosis were lower, but the mean luminal diameter was larger in the three tested groups than that in the control group (P < 0.01). Comparisons of various indices between tested groups treated by different doses of As2O3 showed that the difference between high/median dose vs. low dose was significant (P < 0.01), but that between high dose vs. median dose was insignificant (P > 0.05). Control-releasing As2O3-eluting stent shows a reliable and safe effect in preventing and treating post-stent restenosis by its dose-dependent inhibition on expressions of SMC and CIII to suppress the neo-genesis of intimal hyperplasia.
Long-Term Outcomes of Stenting the Proximal Left Anterior Descending Artery in the PROTECT Trial.
Roguin, Ariel; Camenzind, Edoardo; Kerner, Arthur; Beyar, Rafael; Boersma, Eric; Mauri, Laura; Steg, Ph Gabriel; Wijns, William
2017-03-27
This study sought to compare the outcomes of patients undergoing drug-eluting stent implantation according to lesion location within or outside the proximal left anterior descending (LAD) artery. Proximal LAD artery involvement is considered uniquely in revascularization guidelines. The impact of LAD lesion location on long-term outcomes after revascularization is poorly understood in context of current percutaneous coronary intervention and medical therapy. Among 8,709 patients enrolled in PROTECT (Patient Related Outcomes with Endeavor Versus Cypher Stenting Trial), a multicenter percutaneous coronary intervention trial, we compared the outcomes of 2,534 patients (29.1%) (3,871 lesions [31.5%]) with stents implanted in the proximal LAD to 6,172 patients (70.9%) (8,419 lesions [68.5%]) with stents implanted outside the proximal LAD. At the 4-year follow-up, death rates were the same (5.8% vs. 5.8%; p > 0.999), but more myocardial infarctions occurred in the proximal LAD group (6.2% vs. 4.9%; p = 0.015). The rate of clinically driven target vessel failure (TVF) (14.8% vs. 13.5%; p = 0.109), major adverse cardiac event(s) (MACE) (15.0% vs. 13.7%; hazard ratio: 1.1; 95% confidence interval: 0.97 to 1.31; p = 0.139), and stent thrombosis (2.1% vs. 2.0%; p = 0.800) were similar. Drug-eluting stent type had no interaction with MACE or TVF. In multivariate analysis, the proximal LAD was a predictor of myocardial infarction (p = 0.038) but not of TVF (p = 0.149) or MACE (p = 0.069). In this study of contemporary percutaneous coronary intervention, proximal LAD location was associated with higher rates of myocardial infarction during the long-term follow-up, but there were no differences in stent thrombosis, death, TVF, or overall MACE. This finding may suggest that, in the drug-eluting stent era, proximal LAD no longer confers a different prognosis than other lesion sites. (Randomized Study Comparing Endeavor With Cypher Stents [PROTECT]; NCT00476957). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Kralev, Stefan; Haag, Benjamin; Spannenberger, Jens; Lang, Siegfried; Brockmann, Marc A.; Bartling, Soenke; Marx, Alexander; Haase, Karl-Konstantin; Borggrefe, Martin; Süselbeck, Tim
2011-01-01
Background Treatment of coronary bifurcation lesions remains challenging, beyond the introduction of drug eluting stents. Dedicated stent systems are available to improve the technical approach to the treatment of these lesions. However dedicated stent systems have so far not reduced the incidence of stent restenosis. The aim of this study was to assess the expansion of the Multi-Link (ML) Frontier™ stent in human and porcine coronary arteries to provide the cardiologist with useful in-vitro information for stent implantation and selection. Methodology/Principal Findings Nine ML Frontier™ stents were implanted in seven human autopsy heart samples with known coronary artery disease and five ML Frontier™ stents were implanted in five porcine hearts. Proximal, distal and side branch diameters (PD, DD, SBD, respectively), corresponding opening areas (PA, DA, SBA) and the mean stent length (L) were assessed by micro-computed tomography (micro-CT). PD and PA were significantly smaller in human autopsy heart samples than in porcine heart samples (3.54±0.47 mm vs. 4.04±0.22 mm, p = 0.048; 10.00±2.42 mm2 vs. 12.84±1.38 mm2, p = 0.034, respectively) and than those given by the manufacturer (3.54±0.47 mm vs. 4.03 mm, p = 0.014). L was smaller in human autopsy heart samples than in porcine heart samples, although data did not reach significance (16.66±1.30 mm vs. 17.30±0.51 mm, p = 0.32), and significantly smaller than that given by the manufacturer (16.66±1.30 mm vs. 18 mm, p = 0.015). Conclusions/Significance Micro-CT is a feasible tool for exact surveying of dedicated stent systems and could make a contribution to the development of these devices. The proximal diameter and proximal area of the stent system were considerably smaller in human autopsy heart samples than in porcine heart samples and than those given by the manufacturer. Special consideration should be given to the stent deployment procedure (and to the follow-up) of dedicated stent systems, considering final intravascular ultrasound or optical coherence tomography to visualize (and if necessary optimize) stent expansion. PMID:21814552
Intravascular Optical Imaging Technology for Investigating the Coronary Artery
Suter, Melissa J.; Nadkarni, Seemantini K.; Weisz, Giora; Tanaka, Atsushi; Jaffer, Farouc A.; Bouma, Brett E.; Tearney, Guillermo J.
2012-01-01
There is an ever-increasing demand for new imaging methods that can provide additional information about the coronary wall to better characterize and stratify high-risk plaques, and to guide interventional and pharmacologic management of patients with coronary artery disease. While there are a number of imaging modalities that facilitate the assessment of coronary artery pathology, this review paper focuses on intravascular optical imaging modalities that provide information on the microstructural, compositional, biochemical, biomechanical, and molecular features of coronary lesions and stents. The optical imaging modalities discussed include angioscopy, optical coherence tomography, polarization sensitive-optical coherence tomography, laser speckle imaging, near-infrared spectroscopy, time-resolved laser induced fluorescence spectroscopy, Raman spectroscopy, and near-infrared fluorescence molecular imaging. Given the wealth of information that these techniques can provide, optical imaging modalities are poised to play an increasingly significant role in the evaluation of the coronary artery in the future. PMID:21920342
Sabbah, Mahmoud; Kadota, Kazushige; Fuku, Yasushi; Mitsudo, Kazuaki
2015-01-01
Stent malapposition and overhanging stent struts in front of the side branch (SB) ostium are not uncommon following bifurcation stenting that might lead to stent thrombosis. We herein present 2 cases, in which optical frequency domain imaging and intravascular ultrasound effectively revealed stent malapposition and overhanging struts inside the ostium of the SB following left main coronary artery stenting. Therefore, we introduced a novel technique for rectification of these incidental findings by selective SB re-wiring through the most distal stent cell with the adjunctive help of a double lumen microcatheter. PMID:27122906
Min, James K; Swaminathan, Rajesh V; Vass, Melissa; Gallagher, Scott; Weinsaft, Jonathan W
2009-01-01
The assessment of coronary stents with present-generation 64-detector row computed tomography scanners that use filtered backprojection and operating at standard definition of 0.5-0.75 mm (standard definition, SDCT) is limited by imaging artifacts and noise. We evaluated the performance of a novel, high-definition 64-slice CT scanner (HDCT), with improved spatial resolution (0.23 mm) and applied statistical iterative reconstruction (ASIR) for evaluation of coronary artery stents. HDCT and SDCT stent imaging was performed with the use of an ex vivo phantom. HDCT was compared with SDCT with both smooth and sharp kernels for stent intraluminal diameter, intraluminal area, and image noise. Intrastent visualization was assessed with an ASIR algorithm on HDCT scans, compared with the filtered backprojection algorithms by SDCT. Six coronary stents (2.5, 2.5, 2.75, 3.0, 3.5, 4.0mm) were analyzed by 2 independent readers. Interobserver correlation was high for both HDCT and SDCT. HDCT yielded substantially larger luminal area visualization compared with SDCT, both for smooth (29.4+/-14.5 versus 20.1+/-13.0; P<0.001) and sharp (32.0+/-15.2 versus 25.5+/-12.0; P<0.001) kernels. Stent diameter was higher with HDCT compared with SDCT, for both smooth (1.54+/-0.59 versus1.00+/-0.50; P<0.0001) and detailed (1.47+/-0.65 versus 1.08+/-0.54; P<0.0001) kernels. With detailed kernels, HDCT scans that used algorithms showed a trend toward decreased image noise compared with SDCT-filtered backprojection algorithms. On the basis of this ex vivo study, HDCT provides superior detection of intrastent luminal area and diameter visualization, compared with SDCT. ASIR image reconstruction techniques for HDCT scans enhance the in-stent assessment while decreasing image noise.
2012-01-01
Background Second-generation drug-eluting stents (DES) have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES) is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES). In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI). A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT)) was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS) patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT)) is used more commonly than doubling the dose of clopidogrel in high-risk patients. Methods In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES) and antiplatelet regimen (TAT vs DDAT). The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. Discussion The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. Trial registration ClincalTrials.gov number NCT01267734. PMID:22463698
Wang, Geng; Wang, Heyang; Xu, Bo; Yang, Yuejin; Yang, Zhiming; Li, Hui; Zhang, Zheng; Wang, Haichang; Yang, Lixia; Han, Yaling
2017-03-01
The safety and efficacy of the second-generation biodegradable polymer Cobalt-Chromium sirolimus-eluting stent (EXCEL2) in daily clinical practice remains unknown. Additionally, to meet the China Food and Drug Administration requirements, we conducted an objective performance criterion study from the CREDIT II and CREDIT III trials. CREDIT II was a randomized trial comparing the EXCEL2 versus EXCEL stent in patients with up to 2 de novo coronary lesions. CREDIT III was a prospective, single-arm study evaluating the efficacy and safety of EXCEL2 in broad types of de novo coronary artery lesions. This pooled analysis included patients in the CREDIT III and EXCEL2 arm of the CREDIT II trial. The primary outcome was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinical indicated target lesion revascularization (CI-TLR). The patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization was also analyzed. A total of 833 patients were included, consisting of 625 in the CREDIT III trial and 208 in the EXCEL2 arm of the CREDIT II trial. Twelve-month TLF occurred in 6.1% patients, cardiac death in 0.4%, TV-MI in 5%, and CI-TLR in 1.1%. Additionally, 64 (7.7%) PoCE and 3 probable late stent thromboses (0.4%) were recorded. EXCEL2 stent met the objective performance criterion on efficacy and safety with a low level of 12-month TLF as well as stent thrombosis when treating patients with de novo coronary lesions. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
Drug eluting stents: To evolve or dissolve?
Bharadwaj, Prashant; Chadha, D S
2016-10-01
Currently, percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is the most commonly employed modality in the treatment of patients with coronary artery disease. PCI has come of age over the last four decades with enormous forays in the technology and drugs which have greatly enhanced its capability. Angioplasty and bare metal stents were plagued by high failure rates on account of restenosis leading to repeat revascularization procedures. Insights into pathophysiology of instent restenosis (ISR) and neointimal hyperplasia triggered the development of DES. The dreamlike remarkable reduction in ISR with DES was enthusiastically welcomed. Soon thereafter emerged the spectre of very late stent thrombosis (VLST) with DES. VLST was a new entity seen predominantly with DES and pathological insights as to the cause was instrumental in the development and efficacy of new generation DES. This review will highlight the evolution and present day DES for coronary interventions.
Intravascular Drug Release Kinetics Dictate Arterial Drug Deposition, Retention, and Distribution
Balakrishnan, Brinda; Dooley, John F.; Kopia, Gregory; Edelman, Elazer R.
2007-01-01
Millions of patients worldwide have received drug-eluting stents to reduce their risk for in-stent restenosis. The efficacy and toxicity of these local therapeutics depend upon arterial drug deposition, distribution, and retention. To examine how administered dose and drug release kinetics control arterial drug uptake, a model was created using principles of computational fluid dynamics and transient drug diffusion-convection. The modeling predictions for drug elution were validated using empiric data from stented porcine coronary arteries. Inefficient, minimal arterial drug deposition was predicted when a bolus of drug was released and depleted within seconds. Month-long stent-based drug release efficiently delivered nearly continuous drug levels, but the slow rate of drug presentation limited arterial drug uptake. Uptake was only maximized when the rates of drug release and absorption matched, which occurred for hour-long drug release. Of the two possibly means for increasing the amount of drug on the stent, modulation of drug concentration potently impacts the magnitude of arterial drug deposition, while changes in coating drug mass affect duration of release. We demonstrate the importance of drug release kinetics and administered drug dose in governing arterial drug uptake and suggest novel drug delivery strategies for controlling spatio-temporal arterial drug distribution. PMID:17868948
Naito, Ryo; Miyauchi, Katsumi; Konishi, Hirokazu; Tsuboi, Shuta; Ogita, Manabu; Dohi, Tomotaka; Kajimoto, Kan; Kasai, Takatoshi; Tamura, Hiroshi; Okazaki, Shinya; Isoda, Kikuo; Yamamoto, Taira; Amano, Atsushi; Daida, Hiroyuki
2016-09-01
Coronary artery disease is a critical issue that requires physicians to consider appropriate treatment strategies, especially for elderly people who tend to have several comorbidities, including diabetes mellitus (DM) and multivessel disease (MVD). Several studies have been conducted comparing clinical outcomes between percutaneous coronary intervention (PCI) and coronary artery bypass graft (CABG) in patients with DM and MVD. However, elderly people were excluded in those clinical studies. Therefore, there are no comparisons of clinical outcomes between CABG and PCI in elderly patients with DM and MVD. We compared all-cause mortality between PCI with drug-eluting stents (DES) and CABG in elderly patients with DM and MVD. A total of 483 (PCI; n = 256, CABG; n = 227) patients were analyzed. The median follow-up period was 1356 days (interquartile range of 810-1884). The all-cause mortality rate was not significantly different between CABG and PCI with DES groups. The CABG group had more patients with complex coronary lesions such as three-vessel disease or a left main trunk lesion. Older age, hemodialysis, and reduced LVEF were associated with increased long-term all-cause mortality in a multivariable Cox regression analysis. The rate of all-cause mortality was not significantly different between the PCI and CABG groups in elderly patients with DM and MVD in a single-center study.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stampfl, Ulrike; Sommer, Christof-Matthias; Thierjung, Heidi
2008-11-15
The purpose of this study was to investigate the potential of nanoscale coating with the highly biocompatible polymer Polyzene-F (PZF), in combination with cobalt chromium and stainless steel stents, to reduce in-stent stenosis, thrombogenicity, and vessel wall injury and inflammation. One bare cobalt chromium, PZF-nanocoated stainless steel or PZF-nanocoated cobalt chromium stent was implanted in right coronary artery of 30 mini-pigs (4- or 12-week follow-up). Primary study end points were in-stent stenosis and thrombogenicity. Secondary study end points were vessel wall injury and inflammation as evaluated by microscopy and a new immunoreactivity score applying C-reactive protein (CRP), tumor-necrosis factor alphamore » (TNF{alpha}), and TGF{beta}. At 12 weeks, angiography showed a significantly lower average loss in lumen diameter (2.1% {+-} 3.05%) in PZF-nanocoated cobalt chromium stents compared with stents in the other groups (9.73% {+-} 4.93% for bare cobalt chromium stents and 9.71% {+-} 7% for PZF-nanocoated stainless steel stents; p = 0.04), which was confirmed at microscopy (neointima 40.7 {+-} 16 {mu}m in PZF-nanocoated cobalt chromium stents, 74.7 {+-} 57.6 {mu}m in bare cobalt chromium stents, and 141.5 {+-} 109 {mu}m in PZF-nanocoated stainless steel stents; p = 0.04). Injury and inflammation scores were low in all stents and were without significant differences. PZF-nanocoated cobalt chromium stents provided the highest efficacy in reducing in-stent stenosis at long-term follow-up. The PZF nanocoat proved to be biocompatible with respect to thromboresistance and inflammation. Our data suggest that its combination with cobalt chromium stents might provide an interesting passive stent platform.« less
Rao, D Sheshagiri; Barik, Ramachandra
2016-01-01
Arterial supply of an intralobar pulmonary sequestration (IPS) from the coronary circulation is extremely rare. A significant coronary steal does not occur because of dual or triple sources of blood supply to sequestrated lung tissue. We present a 60-year-old woman who presented to us with repeated episodes of monomorphic ventricular tachycardia (VT) in last 3 mo. Radio frequency ablation was ineffective. On evaluation, she had right lower lobe IPS with dual arterial blood supply, i.e., right pulmonary artery and the systemic arterial supply from the right coronary artery (RCA). Stress myocardial perfusion scan revealed significant inducible ischemia in the RCA territory. Coronary angiogram revealed critical stenosis of proximal RCA just after the origin of the systemic artery supplying IPS. The critical stenosis in the RCA was stented. At 12 mo follow-up, she had no further episodes of VT or angina. PMID:27468336
Rao, D Sheshagiri; Barik, Ramachandra
2016-07-26
Arterial supply of an intralobar pulmonary sequestration (IPS) from the coronary circulation is extremely rare. A significant coronary steal does not occur because of dual or triple sources of blood supply to sequestrated lung tissue. We present a 60-year-old woman who presented to us with repeated episodes of monomorphic ventricular tachycardia (VT) in last 3 mo. Radio frequency ablation was ineffective. On evaluation, she had right lower lobe IPS with dual arterial blood supply, i.e., right pulmonary artery and the systemic arterial supply from the right coronary artery (RCA). Stress myocardial perfusion scan revealed significant inducible ischemia in the RCA territory. Coronary angiogram revealed critical stenosis of proximal RCA just after the origin of the systemic artery supplying IPS. The critical stenosis in the RCA was stented. At 12 mo follow-up, she had no further episodes of VT or angina.
Current evidence for the safety and efficacy of the bio-engineered dual therapy COMBO stent.
Kalkman, Deborah N; Chandrasekhar, Jaya; de Winter, Robbert J; Mehran, Roxana
2018-06-01
The novel dual-therapy COMBO stent aims to promote vessel healing after percutaneous coronary intervention (PCI) in patients with coronary artery disease. The pro-healing technique consists of an anti-CD34+ antibody layer that attracts circulating endothelial progenitor cells (EPCs), which bind to the stent surface and allow rapid endothelialization by differentiation of the EPCs into normal endothelial cells. The COMBO stent combines this pro-healing technique with an abluminal drug elution of sirolimus. The promise of this dual-therapy stent is that it may safely allow a shortened duration of dual-antiplatelet therapy (DAPT) after stent placement. Moreover, with a mature endothelial layer, lower rates of in-stent restenosis may be expected. Clinical outcomes after COMBO stent implantation have been recently evaluated in both randomized trials and large, prospective, multicenter registries, showing low clinical event rates of in-stent restenosis and stent thrombosis. Randomized clinical trials (HARMONEE and RECOVERY) have demonstrated the non-inferiority of COMBO versus "first in class" second generation and newer generation drug-eluting stents. Safety and efficacy of 3 months of DAPT after COMBO stent placement in patients presenting with acute coronary syndrome has been evaluated in the large REDUCE randomized controlled trial, showing non-inferiority to standard duration of 12-month DAPT. In this review we provide an overview of the current pre-clinical and clinical evidence for the performance of the COMBO stent.
Mina, George S; Watti, Hussam; Soliman, Demiana; Shewale, Anand; Atkins, Jessica; Reddy, Pratap; Dominic, Paari
2018-01-05
Most data guiding revascularization of multivessel disease (MVD) and/or left main disease (LMD) favor coronary artery bypass grafting (CABG) over percutaneous coronary intervention (PCI). However, those data are based on trials comparing CABG to bare metal stents (BMS) or old generation drug eluting stents (OG-DES). Hence, it is essential to outcomes of CABG to those of new generation drug eluting stents (NG-DES). We searched PUBMED and Cochrane database for trials evaluating revascularization of MVD and/or LMD with CABG and/or PCI. A Bayesian network meta-analysis was performed to calculate odds ratios (OR) and 95% credible intervals (CrI). Primary outcome was major adverse cardiovascular events (MACE) at 3-5 years. Secondary outcomes were mortality, cerebrovascular accidents (CVA), myocardial infarction (MI) and repeat revascularization. We included 10 trials with a total of 9287 patients. CABG was associated with lower MACE when compared to BMS or OG-DES. However, MACE was not significantly different between CABG and NG-DES (OR 0.79, CrI 0.45-1.40). Moreover, there were no significant differences between CABG and NG-DES in mortality (OR 0.78, CrI 0.45-1.37), CVA (OR 0.93 CrI 0.35-2.2) or MI (OR 0.6, CrI 0.17-2.0). On the other hand, CABG was associated with lower repeat revascularization (OR 0.55, CrI 0.36-0.84). Our study suggests that NG-DES is an acceptable alternative to CABG in patients with MVD and/or LMD. However, repeat revascularization remains to be lower with CABG than with PCI. Copyright © 2018. Published by Elsevier Inc.
Koh, Jin-Sin; Kang, Min-Kyung; Ahn, Yeon-Jeong; Kim, In-Suk; Park, Yongwhi; Hwang, Seok-Jae; Kwak, Choong Hwan; Hwang, Jin-Yong
2010-01-01
Background/Aims In patients with coronary artery stents, the cost of clopidogrel has been cited as a factor in the premature discontinuation of therapy. Thus, the introduction of lower-cost generic clopidogrel may increase patient compliance. However, platelet inhibition by generic clopidogrel has not been compared to the original clopidogrel formulation in patients with coronary artery stents. Methods We prospectively enrolled 20 patients receiving chronic therapy with the original clopidogrel bisulfate (Plavix®). After assessing patient compliance with Plavix®, maintenance therapy was switched to generic clopidogrel bisulfate (Plavitor®). Platelet reactivity was assessed at baseline and 30-day after the switch using conventional aggregometry and the VerifyNow P2Y12 assay. Results All patients completed maintenance therapy with Plavitor®. Before and after switching therapy maximal (36.5 ± 7.9% vs. 39.8 ± 16.2%, p = 0.280) and late platelet aggregation (23.5 ± 10.9% vs. 29.1 ± 18.3%, p = 0.156) with 5 µmol/L adenosine diphosphate (ADP) stimulus did not differ. Likewise, 20 µmol/L ADP-induced platelet aggregation and P2Y12 reaction unit in patients on Plavitor® therapy was comparable to that in patients on Plavix® therapy. However, Bland-Altman analysis showed wide limits of agreement between measured platelet reactivity on Plavix® vs. Plavitor® therapies. Conclusions Among patients on Plavix® maintenance therapy with coronary stents, replacement with Plavitor® shows a comparable inhibition of ADP-induced platelet aggregation. However, due to poor inter-therapy agreement, between two regimens, physicians may be cautious when introducing generic clopidogrel bisulfate. PMID:20526388
Analysis of trends and prospects regarding stents for human blood vessels.
Lee, Jeong Hee; Kim, Eung Do; Jun, Eun Jung; Yoo, Hyoung Sun; Lee, Joon Woo
2018-01-01
The purpose of this paper is to provide technology trends and information regarding market and prospects in stents used for human blood vessels in Korea and the world.A stent is a medical device in the form of a cylindrical metal net used to normalize flow when blood or other bodily fluids such as biliary fluids are obstructed in blood vessels, gastrointestinal tracts, etc. by inserting the stent into a narrowed or clogged area. Stents are classified into vascular and non-vascular stents. The coronary artery stent is avascular stent that is used for coronary atherosclerosis.The demand is increasing for stents to treat diseases such as those affecting the heart and blood vessels of elderly and middle-aged patients. Due to the current shift in the demographic structure caused by an aging society, the prospect for stents seems to be very bright.The use of a stent designed to prevent acute vascular occlusion and restenosis, which is a side effect of conventional balloon angioplasty, has rapidly become popular because it can prevent acute complications and improve clinical outcomes. Since the initial release of this stent, there have been significant developments in its design, the most notable of which has been the introduction of drug-eluting stents (DES). Bioresorbable scaffolds (BRS) have the potential to introduce a paradigm shift in interventional cardiology, a true anatomical and functional "vascular restoration" instead of an artificial stiff tube encased by a persistent metallic foreign body. Data for this research were gathered from primary and secondary sources as well as the databases of the Korea Institute of Science Technology Information (KISTI) located in Seoul, Korea like KISTI Market Report. The sources used for primary research included the databases available from the Korea Institute of Science Technology Information, past industry research services/studies, economic and demographic data, and trade and industry journals. Secondary research was used to supplement and complement the primary research. Interviews were conducted with physicians and surgeons from the key hospitals and senior sale/marketing managers from stent product suppliers in South Korea. The global stent market is estimated at US $ 7.98 billion in 2016 and is expected to grow at a Compound Annual Growth Rate (CAGR) of 3.8% over the next 5 years. As of 2016, the global market for vascular stents is estimated at $ 7.22 billion, with coronary artery stents accounting for 67.3% of the vascular stent market. Among the coronary artery stents, BRS is notably expected to grow at an annual average rate of 8.8% by 2020, but the global adoption rate of BRS remains low at present. In the Korean market, stents for blood vessels account for most of the market, and the market size of stents for blood vessels in Korea was estimated to be 145 billion won as of 2016. In comparison to the sales growth rate of other medical devices, the future stent technology market is judged to be higher in growth potential.
Zhang, Qi; Wang, Xiao Long; Liao, Min Lei; Hu, Jian; Yang, Zhen Kun; Ding, Feng Hua; Zhang, Jian Sheng; Du, Run; Zhu, Tian Qi; Shen, Wei Feng; Zhang, Rui Yan
2015-03-01
Patients are at risk of developing periprocedural myonecrosis after percutaneous coronary intervention (PCI). We investigated whether the use of the platelet glycoprotein (GP) IIb/IIIa receptor inhibitor tirofiban could reduce periprocedural myocardial infarction (PMI) in patients with stable coronary artery disease undergoing elective PCI with overlapping stent implantation for long lesions. A total of 748 stable angina patients with long lesions (≥ 40 mm in length) treated with overlapping stent implantation were randomly assigned to receive tirofiban (tirofiban group; n = 373) or conventional therapy (control group; n = 375). Intravenous tirofiban was initiated before PCI and maintained for 12 hr after the procedure. The primary endpoint was PMI, defined as an elevation in CK-MB > 3 times the upper limit of normal 12 hr after the index procedure. The secondary endpoint was major adverse cardiac events (MACE), including cardiac death, target vessel revascularization, and recurrent MI (re-MI), at one-year of clinical follow-up. The safety end-points included Thrombolysis in Myocardial Infarction (TIMI) major bleeding and stent thrombosis. Despite comparable angiographic and procedural characteristics, in the intention-to-treatment analysis, the primary endpoint was significantly reduced in the tirofiban group (4.0% vs. 11.5%, P < 0.001). Multivariate analysis revealed that the adjunctive use of tirofiban was the only negative predictor of PMI (OR 0.41, 95% CI 0.28-0.81, P < 0.01). At one-year of clinical follow-up, the overall occurrence of MACE was significantly lower in the tirofiban group (13.4% vs. 22.7%, P = 0.001). The rate of TIMI major bleeding and stent thrombosis did not differ significantly between the two groups. Our results show that the adjunctive use of tirofiban reduces the occurrence of PMI and MACE at one year in stable coronary artery disease patients undergoing elective PCI for long lesions with overlapping stent implantation. © 2015 Wiley Periodicals, Inc.
Clinical outcomes in metabolic syndrome.
Bhatheja, Rohit; Bhatt, Deepak L
2006-01-01
Metabolic syndrome is a clustering of cardiovascular risk factors. Its definition is the presence of any 3 of the following: obesity, hypertriglyceridemia, low high-density lipoprotein, hypertension, and impaired fasting glucose. The development of coronary artery disease is the most dreaded complication of this disease. In the United States, Mexican Americans and African American women are the most affected. Management of this syndrome includes physical exercise, weight loss, and effective drug treatment of dyslipidemia, high blood pressure, and impaired fasting blood glucose. Because of the increasing prevalence of obesity and diabetes, there is a rise in fatal and nonfatal cardiovascular events. With the development of effective antiplatelet medication and newer drug-eluting stents, percutaneous coronary intervention has become an effective revascularization strategy for those with coronary artery disease. Rates of stent restenosis and target-lesion revascularization have been reduced. Oral hypoglycemic drugs like thiazolidinediones improve insulin resistance and may have a favorable effect in those with metabolic syndrome. Diagnosis and appropriate management of metabolic syndrome are challenges as the presence of risk factors predates the coronary event.
Xiu, Jiancheng; Chen, Gangbin; Zheng, Hua; Wang, Yuegang; Chen, Haibin; Liu, Xuewei; Wu, Juefei; Bin, Jianping
2016-02-01
Fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) is used to assess the need for angioplasty in vessels with intermediate blockages. The treatment outcomes of FFR-guided vs. conventional angiography-guided PCI were evaluated in patients with multi-vessel coronary artery disease (CAD). Prospective and retrospective studies comparing FFR-guided vs. angiography-guided PCI in patients with multi-vessel CAD were identified from medical databases by two independent reviewers using the terms "percutaneous coronary intervention, fractional flow reserve, angiography, coronary heart disease, major adverse cardiac events (MACE) and myocardial infarction". The primary outcome was the number of stents placed, and the secondary outcomes were procedure time, mortality, myocardial infarction (MI) and MACE rates. Seven studies (three retrospective and four prospective), which included 49,517 patients, were included in this review. A total of 4,755 patients underwent FFR, while 44,697 received angiography-guided PCI. The mean patient age ranged from 58 to 71.7 years. The average number of stents used in FFR patients ranged from 0.3-1.9, and in angiography-guided PCI patients ranged from 0.7-2.7. Analysis indicated there was a greater number of stents placed in the angiography-guided group compared with the FFR group (pooled difference in means: -0.64, 95% confidence interval [CI]: -0.81 to -0.47, P < 0.001). There were no differences in the secondary outcomes between the two groups. Both procedures produce similar clinical outcomes, but the fewer number of stents used with FFR may have clinical as was as cost implications.
Yang, Wen Jie; Zhang, Huan; Xiao, Hua; Li, Jian Ying; Liu, Yan; Pan, Zi Lai; Chen, Ke Min
2012-01-01
The evaluation of coronary stents by computed tomography (CT) remains difficult. We assessed the imaging performance of a high-definition CT scanner (HDCT) by comparing with a conventional 64-row standard-definition CT (SDCT). One hundred thirty-eight consecutive stented patients underwent coronary CT angiography, among whom 66 patients were examined by HDCT, and 72 patients by SDCT (LightSpeed VCT XT; GE Healthcare, Waukesha, Wis). The image quality score, the inner stent diameter (ISD), and the radiation dose were analyzed. All data were statistically tested by SPSS 13.0 software (SPSS Inc, Chicago, Ill). In 72 patients examined using SDCT, 135 stents were detected; in 66 patients examined using HDCT, 119 stents were detected. The image quality score on HDCT was significantly better than that on SDCT (1.4 [SD, 0.7] vs 1.9 [SD, 0.8]). The ISD on HDCT was significantly higher than that on SDCT (1.8 [SD, 0.5] vs 1.6 [SD, 0.4]). There was no significant difference of either image quality score or ISD between the HDCT and SDCT groups in stents with 2.5-mm diameter. Images on HDCT showed significantly better image quality score and larger ISD than images on SDCT in 2.75-, 3-, and 3.5-mm stents. For patients examined by retrospective electrocardiogram-gated technique, the radiation dose on HDCT was significantly lower than that on SDCT (11.3 [SD, 2.9] vs 15.1 [SD, 3.8] mSv). High-definition CT scanner offered improved image quality and measurement accuracy for imaging coronary stents compared with conventional SDCT, providing higher spatial resolution and lower dose for evaluating coronary stents with 2.75- to 3.5-mm diameter.
CABG Versus PCI: Greater Benefit in Long-Term Outcomes With Multiple Arterial Bypass Grafting.
Habib, Robert H; Dimitrova, Kamellia R; Badour, Sanaa A; Yammine, Maroun B; El-Hage-Sleiman, Abdul-Karim M; Hoffman, Darryl M; Geller, Charles M; Schwann, Thomas A; Tranbaugh, Robert F
2015-09-29
Treatment of multivessel coronary artery disease with traditional single-arterial coronary artery bypass graft (SA-CABG) has been associated with superior intermediate-term survival and reintervention compared with percutaneous coronary intervention (PCI) using either bare-metal stents (BMS) or drug-eluting stents (DES). This study sought to investigate longer-term outcomes including the potential added advantage of multiarterial coronary artery bypass graft (MA-CABG). We studied 8,402 single-institution, primary revascularization, multivessel coronary artery disease patients: 2,207 BMS-PCI (age 66.6 ± 11.9 years); 2,381 DES-PCI (age 65.9 ± 11.7 years); 2,289 SA-CABG (age 69.3 ± 9.0 years); and 1,525 MA-CABG (age 58.3 ± 8.7 years). Patients with myocardial infarction within 24 h, shock, or left main stents were excluded. Kaplan-Meier analysis and Cox regression were used to separately compare 9-year all-cause mortality and unplanned reintervention for BMS-PCI and DES-PCI to respective propensity-matched SA-CABG and MA-CABG cohorts. BMS-PCI was associated with worse survival than SA-CABG, especially from 0 to 7 years (p = 0.015) and to a greater extent than MA-CABG was (9-year follow-up: 76.3% vs. 86.9%; p < 0.001). The surgery-to-BMS-PCI hazard ratios (HR) were as follows: versus SA-CABG, HR: 0.87; and versus MA-CABG, HR: 0.38. DES-PCI showed similar survival to SA-CABG except for a modest 0 to 3 years surgery advantage (HR: 1.06; p = 0.615). Compared with MA-CABG, DES-PCI exhibited worse survival at 5 (86.3% vs. 95.6%) and 9 (82.8% vs. 89.8%) years (HR: 0.45; p <0.001). Reintervention was substantially worse with PCI for all comparisons (all p <0.001). Multiarterial surgical revascularization, compared with either BMS-PCI or DES-PCI, resulted in substantially enhanced death and reintervention-free survival. Accordingly, MA-CABG represents the optimal therapy for multivessel coronary artery disease and should be enthusiastically adopted by multidisciplinary heart teams as the best evidence-based therapy. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Hocine, Nora; Meignan, Michel; Masset, Hélène
2018-04-01
To better understand the risks of cumulative medical X-ray investigations and the possible causal role of contrast agent on the coronary artery wall, the correlation between iodinated contrast media and the increase of energy deposited in the coronary artery lumen as a function of iodine concentration and photon energy is investigated. The calculations of energy deposition have been performed using Monte Carlo (MC) simulation codes, namely PENetration and Energy LOss of Positrons and Electrons (PENELOPE) and Monte Carlo N-Particle eXtended (MCNPX). Exposure of a cylinder phantom, artery and a metal stent (AISI 316L) to several X-ray photon beams were simulated. For the energies used in cardiac imaging the energy deposited in the coronary artery lumen increases with the quantity of iodine. Monte Carlo calculations indicate a strong dependence of the energy enhancement factor (EEF) on photon energy and iodine concentration. The maximum value of EEF is equal to 25; this factor is showed for 83 keV and for 400 mg Iodine/mL. No significant impact of the stent is observed on the absorbed dose in the artery for incident X-ray beams with mean energies of 44, 48, 52 and 55 keV. A strong correlation was shown between the increase in the concentration of iodine and the energy deposited in the coronary artery lumen for the energies used in cardiac imaging and over the energy range between 44 and 55 keV. The data provided by this study could be useful for creating new medical imaging protocols to obtain better diagnostic information with a lower level of radiation exposure.
Early clinical outcomes of primary percutaneous coronary intervention in bharatpur, Nepal.
Dubey, Laxman; Bhattacharya, Rabindra; Guruprasad, Sogunuu; Subramanyam, Gangapatnam
2013-06-01
Primary percutaneous coronary intervention represents one of the cornerstone management modalities for patients with acute ST-elevation myocardial infarction and has undergone tremendous growth over the past two decades. This study was aimed to determine the early clinical outcomes of primary percutaneous coronary interventions in a tertiary-level teaching hospital without onsite cardiac surgery backup. This was a prospective descriptive study which included all consecutive patients who were admitted for primary percutaneous coronary interventions between March 2011 and January 2013 at the College of Medical Sciences and Teaching Hospital, Bharatpur, Nepal. Total 68 patients underwent primary percutaneous coronary interventions as a mode of revascularization. The primary end point of the study was to identify in-hospital as well as 30-day clinical outcomes of primary percutaneous coronary interventions. The mean age was 56.31 ± 11.47 years, with age range of 32 years to 91 years. Of the 68 primary percutaneous coronary interventions performed, 15 (22.05%) were carried out in women and 10 (14.70%) in patients over 75 years of age. Primary percutaneous coronary intervention for anterior wall myocardial infarction was more common than for non-anterior wall myocardial infarction (55.88% vs. 44.12%). Proximal artery stenting was performed in 38.50% and the non proximal artery stenting in 61.50%. The outcomes were mortality (5.88%), cardiogenic shock (5.88%), contrast-induced nephropathy requiring dialysis (2.94%), arrhythmias requiring treatment (4.41%), early stent thrombosis (2.94%) and minor complications (14.70%). Primary percutaneous coronary intervention improves the early clinical outcomes in patient with acute ST-elevation myocardial infarction. Despite having no onsite cardiac surgery backup, primary percutaneous coronary intervention was feasible with acceptable complications in a tertiary-care teaching hospital.
Immediate outcomes of eptifibatide therapy during intracoronary stent implantation.
Shariati, Hooman; Sanei, Hamid; Pourmoghadas, Ali; Salehizadeh, Leila; Amirpour, Afshin
2016-01-01
The objective of the present study was to assess the major immediate outcomes of eptifibatide therapy during intracoronary stent implantation. In an interventional study, patients undergoing percutaneous coronary intervention (PCI) were randomized into either the eptifibatide ( n = 100) or the control ( n = 107) group. In each group, demographic and clinical characteristics such as cardiac death, stent thrombosis (ST), myocardial infarction (MI), rates of target lesion and vessel revascularization, cerebral vascular accident (CVA), and emergency coronary artery bypass grafting (CABG) were recorded. The overall rates of major adverse events such as mortality, Stent thrombosis (ST), Myocardial Infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR), CVA, and emergency CABG within 24 h after stent implantation were low and comparable between the two groups; P > 0.05 considered significant for all comparisons. There were no statistical differences between the clinical outcomes of groups administered with single-dose intracoronary eptifibatide and control groups among patients undergoing PCI during stent implantation.
Heart imaging: the accuracy of the 64-MSCT in the detection of coronary artery disease.
Alessandri, N; Di Matteo, A; Rondoni, G; Petrassi, M; Tufani, F; Ferrari, R; Laghi, A
2009-01-01
At present, coronary angiography represents the gold standard technique for the diagnosis of coronary artery disease. Our aim is to compare the conventional coronary angiography to the coronary 64-multislice spiral computed tomography (64-MSCT), a new and non-invasive cardiac imaging technique. The last generation of MSCT scanners show a better imaging quality, due to a greater spatial and temporal resolution. Four expert observers (two cardiologists and two radiologists) have compared the angiographic data with the accuracy of the 64-MSCT in the detection and evaluation of coronary vessels stenoses. From the data obtained, the sensibility, the specificity and the accuracy of the coronary 64-MSCT have been defined. We have enrolled 75 patients (57 male, 18 female, mean age 61.83 +/- 10.38; range 30-80 years) with known or suspected coronary artery disease. The above population has been divided into 3 groups: Group A (Gr. A) with 40 patients (mean age 60.7 +/- 12.5) affected by both non-significant and significant coronary artery disease; Group B (Gr. B) with 25 patients (mean age 60.3 +/- 14.6) who underwent to percutaneous coronary intervention (PCI); Group C (Gr. C) with 10 patients (mean age 54.20 +/- 13.7) without any coronary angiographic stenoses. All the patients underwent non-invasive exams, conventional coronary angiography and coronary 64-MSCT. The comparison of the data obtained has been carried out according to a per group analysis, per patient analysis and per segment analysis. Moreover, the accuracy of the 64-MSCT has been defined for the detection of >75%, 50-75% and <50% coronary stenoses. Coronary angiography has identified significant coronary artery disease in 75% of the patients in the Gr. A and in 73% of the patients in the Gr. B. No coronary stenoses have been detected in Gr. C. According to a per segment analysis, in Gr. A, 36% of the segments analysed have shown a coronary stenosis (37% stenoses >75%, 32% stenoses 50-75% and 31% stenoses <50%). In Gr. B, 32% of the segments have shown a coronary stenosis (33% stenoses >75%, 29% stenoses 50-75% and 38% stenoses <50%). In-stent disease has been shown in only 4 of the 29 coronary stents identified. In Gr. A, coronary 64-MSCT has confirmed the angiographic results in the 93% of cases (sensibility 93%, specificity 100%, positive predictive value 100% and negative predictive value 83%) while, in Gr. B, this confirm has been obtained only in 64% of cases (sensibility 64%, specificity 100%, positive predictive value 100% and negative predictive value 50%). In Gr. C, we have observed a complete agreement between angiographic and CT data (sensibility, specificity, positive predictive value and negative predictive value 100%). According to a per segment analysis, the angiographic results have been confirmed in 98% of cases in Gr. A (sensibility 98%, specificity 94%, positive predictive value 90% and negative predictive value 94%) but only in 55% of cases in Gr. B (sensibility 55%, specificity 90%, positive predictive value 71% and negative predictive value 81%). Moreover, only 1 of the 4 in-stent restenoses has been detected (sensibility 25%, specificity 100%, positive predictive value 100% and negative predictive value 77%). Coronary angiography has detected a greater number of coronary stenoses than the 64-MSCT. 64-MSCT has demonstrated better accuracy in the study of coronary vessels wider than 2 mm, while its accuracy is lower for smaller vessels (diameter < 2.5 mm) and for the identification of in-stent restenosis, because there is a reduced image quality for these vessels and therefore a lower accuracy in the coronary stenosis detection. Nevertheless, 64-MSCT shows high accuracy and it can be considered a comparative but not a substitutive exam of the coronary angiography. Several technical limitations of the 64-MSCT are responsible of its lower accuracy versus the conventional coronary angiography, but solving these technical problems could give us a new non-invasive imaging technique for the study of coronary stents.
Stents: Biomechanics, Biomaterials, and Insights from Computational Modeling.
Karanasiou, Georgia S; Papafaklis, Michail I; Conway, Claire; Michalis, Lampros K; Tzafriri, Rami; Edelman, Elazer R; Fotiadis, Dimitrios I
2017-04-01
Coronary stents have revolutionized the treatment of coronary artery disease. Improvement in clinical outcomes requires detailed evaluation of the performance of stent biomechanics and the effectiveness as well as safety of biomaterials aiming at optimization of endovascular devices. Stents need to harmonize the hemodynamic environment and promote beneficial vessel healing processes with decreased thrombogenicity. Stent design variables and expansion properties are critical for vessel scaffolding. Drug-elution from stents, can help inhibit in-stent restenosis, but adds further complexity as drug release kinetics and coating formulations can dominate tissue responses. Biodegradable and bioabsorbable stents go one step further providing complete absorption over time governed by corrosion and erosion mechanisms. The advances in computing power and computational methods have enabled the application of numerical simulations and the in silico evaluation of the performance of stent devices made up of complex alloys and bioerodible materials in a range of dimensions and designs and with the capacity to retain and elute bioactive agents. This review presents the current knowledge on stent biomechanics, stent fatigue as well as drug release and mechanisms governing biodegradability focusing on the insights from computational modeling approaches.
Verheye, Stefan; Khattab, Ahmed A; Carrie, Didier; Stella, Pieter; Slagboom, Ton; Bartunek, Jozef; Onuma, Yoshinobu; Serruys, Patrick W
2016-08-05
Our aim was to demonstrate the safety and efficacy of the Svelte sirolimus-eluting coronary stent-on-a-wire Integrated Delivery System (IDS) with bioresorbable drug coating compared to the Resolute Integrity zotarolimus-eluting stent with durable polymer in patients with de novo coronary artery lesions. Direct stenting, particularly in conjunction with transradial intervention (TRI), has been associated with reduced bleeding complications, procedure time, radiation exposure and contrast administration compared to conventional stenting with wiring and predilatation. The low-profile Svelte IDS is designed to facilitate TRI and direct stenting, reducing the number of procedural steps, time and cost associated with coronary stenting. DIRECT II was a prospective, multicentre trial which enrolled 159 patients to establish non-inferiority of the Svelte IDS versus Resolute Integrity using a 2:1 randomisation. The primary endpoint was angiographic in-stent late lumen loss (LLL) at six months. Target vessel failure (TVF), as well as secondary clinical endpoints, will be assessed annually up to five years. At six months, in-stent LLL was 0.09±0.31 mm in the Svelte IDS group compared to 0.13±0.27 mm in the Resolute Integrity group (p<0.001 for non-inferiority). TVF at one year was similar across the Svelte IDS and Resolute Integrity groups (6.5% vs. 9.8%, respectively). DIRECT II demonstrated the non-inferiority of the Svelte IDS to Resolute Integrity with respect to in-stent LLL at six months. Clinical outcomes at one year were comparable between the two groups.
Sinha, Santosh Kumar; Razi, Mahmodula; Mahrotra, Anupam; Aggarwal, Puneet; Singh, Anupam; Rekwal, Lokendra; Tripathi, Sunil; Abhishekh, Nishant Kumar; Krishna, Vinay
2018-04-01
Anomalies of the coronary arteries are reported in 1-2% of patients among diagnostic angiogram. Ectopic origin of right coronary artery (RCA) from opposite sinus is one of the most common and they are mainly benign, but at times may be malignant. We report a case of a 69-year-old male who underwent early invasive percutaneous coronary intervention for non-ST-segment elevation myocardial infarction (NSTEMI) where RCA arising from left sinus at the root of left main artery was culprit and various technical challenges were encountered while intervening in form of cannulation to tracking of hardwares. RCA was cannulated with floating wire technique using hockey stick guide catheter and revascularized by deployment of 3.5 × 38 mm Promus Premier Everolimus eluting stent (Boston Scientific, USA). To the best of our knowledge, this is the first ever report of ectopic RCA being revascularized by using hockey stick catheter.
Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease.
Ellis, Stephen G; Kereiakes, Dean J; Metzger, D Christopher; Caputo, Ronald P; Rizik, David G; Teirstein, Paul S; Litt, Marc R; Kini, Annapoorna; Kabour, Ameer; Marx, Steven O; Popma, Jeffrey J; McGreevy, Robert; Zhang, Zhen; Simonton, Charles; Stone, Gregg W
2015-11-12
In patients with coronary artery disease who receive metallic drug-eluting coronary stents, adverse events such as late target-lesion failure may be related in part to the persistent presence of the metallic stent frame in the coronary-vessel wall. Bioresorbable vascular scaffolds have been developed to attempt to improve long-term outcomes. In this large, multicenter, randomized trial, 2008 patients with stable or unstable angina were randomly assigned in a 2:1 ratio to receive an everolimus-eluting bioresorbable vascular (Absorb) scaffold (1322 patients) or an everolimus-eluting cobalt-chromium (Xience) stent (686 patients). The primary end point, which was tested for both noninferiority (margin, 4.5 percentage points for the risk difference) and superiority, was target-lesion failure (cardiac death, target-vessel myocardial infarction, or ischemia-driven target-lesion revascularization) at 1 year. Target-lesion failure at 1 year occurred in 7.8% of patients in the Absorb group and in 6.1% of patients in the Xience group (difference, 1.7 percentage points; 95% confidence interval, -0.5 to 3.9; P=0.007 for noninferiority and P=0.16 for superiority). There was no significant difference between the Absorb group and the Xience group in rates of cardiac death (0.6% and 0.1%, respectively; P=0.29), target-vessel myocardial infarction (6.0% and 4.6%, respectively; P=0.18), or ischemia-driven target-lesion revascularization (3.0% and 2.5%, respectively; P=0.50). Device thrombosis within 1 year occurred in 1.5% of patients in the Absorb group and in 0.7% of patients in the Xience group (P=0.13). In this large-scale, randomized trial, treatment of noncomplex obstructive coronary artery disease with an everolimus-eluting bioresorbable vascular scaffold, as compared with an everolimus-eluting cobalt-chromium stent, was within the prespecified margin for noninferiority with respect to target-lesion failure at 1 year. (Funded by Abbott Vascular; ABSORB III ClinicalTrials.gov number, NCT01751906.).
Khattab, Ahmed A; Hamm, Christian W; Senges, Jochen; Toelg, Ralph; Geist, Volker; Bonzel, Tassilo; Kelm, Malte; Levenson, Benny; Neumann, Franz‐Josef; Nienaber, Christoph A; Pfannebecker, Thomas; Sabin, Georg; Schneider, Steffen; Tebbe, Ulrich; Richardt, Gert
2007-01-01
Background Percutaneous coronary intervention (PCI) of left main coronary artery (LMCA) disease in the bare stent era was limited by high restenosis rates which eventually resulted in sudden death in unprotected cases. Clinical and angiographic restenosis has been substantially reduced by drug‐eluting stents, reviving therefore this indication for PCI despite the absence of direct comparative studies with coronary artery bypass graft surgery. Objective To assess the acute, mid‐ and long‐term outcomes of patients treated with sirolimus‐eluting stents for unprotected LMCA stenoses and to compare them with those treated for protected LMCA disease in the same time period from the German Cypher Registry. Setting and patients The German Cypher Registry included 6755 patients. Eighty‐two patients treated for unprotected LMCA disease were compared with 118 patients treated for protected LMCA stenoses. All patients were treated by sirolimus‐eluting stents. The primary end point was death, myocardial infarction (MI) and target vessel revascularisation at 6 months' follow‐up. Survival free of MI at the long term was considered as the safety end point. Results One‐third of the patients in both groups were treated for the distal left main bifurcation. Angiographic success was 98.5% for both groups. The cumulative combined incidence of all‐cause death, non‐fatal MI and target vessel revascularisation at 6 months was 14.1% in the unprotected LMCA group and 13.1% in the protected group (hazard ratio = 0.81 (95% CI 0.37 to 1.74), p = 0.8). At long‐term, death/MI were reported among 20.2% (95% CI 13.5% to 29.6%) of the protected group versus 11.8% (95% CI 6.3% to 21.4%) of the unprotected group (p = 0.2). Conclusion Sirolimus‐eluting stent treatment of unprotected and protected LMCA stenoses is technically feasible in widespread routine clinical use. Acceptable long‐term clinical results can be achieved, with no particular safety concerns about treatment of unprotected LMCA disease. PMID:17890701
Zhang, Fan; Tongo, Nosakhare Douglas; Hastings, Victoria; Kanzali, Parisa; Zhu, Ziqiang; Chadow, Hal; Rafii, Shahrokh E
2017-04-29
BACKGROUND Acute coronary syndrome (ACS) can present with atypical chest pain or symptoms not attributed to heart disease, such as indigestion. Hiccups, a benign and self-limited condition, can become persistent or intractable with overlooked underlying etiology. There are various causes of protracted hiccups, including metabolic abnormalities, psychogenic disorders, malignancy, central nervous system pathology, medications, pulmonary disorders, or gastrointestinal etiologies. It is rarely attributed to cardiac disease. CASE REPORT We report a case of intractable hiccups in a 51-year-old male with cocaine related myocardial infarction (MI) before and after stent placement. Coronary angiogram showed in-stent thrombosis of the initial intervention. Following thrombectomy, balloon angioplasty, and stent, the patient recovered well without additional episodes of hiccups. Although hiccups are not known to present with a predilection for a particular cause of myocardial ischemia, this case may additionally be explained by the sympathomimetic effects of cocaine, which lead to vasoconstriction of coronary arteries. CONCLUSIONS Hiccups associated with cardiac enzyme elevation and EKG ST-segment elevation before and after percutaneous coronary intervention (PCI) maybe a manifestation of acute MI with or without stent. The fact that this patient was a cocaine user may have contributed to the unique presentation.
External Compression of Epicardial Coronary Arteries with Partial Calcific Pericarditis
Khan, Zubair Ahmed; Sardar, Muhammad Rizwan; Topalian, Simon K.
2017-01-01
Calcific pericarditis (CP) is a rare disease which results from long-standing pericardial inflammation. Pericardial calcification may completely or partially encase the ventricles, resulting in impaired diastolic filling. We present a case of a 53-year-old male who was incidentally found to have annular CP resulting in external compression of a large territory diagonal branch (D1) reaching the apex with likely chronically occluded left anterior descending artery with collateral circulation from the right coronary artery with hemodynamic compromise on coronary angiography. This was emergently treated with a drug-eluting stent with improved D1 flow and entailed the importance of percutaneous coronary intervention as a viable option in cases of CP resulting in acute hemodynamic compromise. PMID:28584590
External Compression of Epicardial Coronary Arteries with Partial Calcific Pericarditis.
Khan, Zubair Ahmed; Sardar, Muhammad Rizwan; Topalian, Simon K
2017-01-01
Calcific pericarditis (CP) is a rare disease which results from long-standing pericardial inflammation. Pericardial calcification may completely or partially encase the ventricles, resulting in impaired diastolic filling. We present a case of a 53-year-old male who was incidentally found to have annular CP resulting in external compression of a large territory diagonal branch (D1) reaching the apex with likely chronically occluded left anterior descending artery with collateral circulation from the right coronary artery with hemodynamic compromise on coronary angiography. This was emergently treated with a drug-eluting stent with improved D1 flow and entailed the importance of percutaneous coronary intervention as a viable option in cases of CP resulting in acute hemodynamic compromise.
Ramakrishna, C. D.; Dave, Bhargav A.; Kothavade, Pankaj S.; Joshi, Kajal J.
2017-01-01
The technology of percutaneous coronary intervention for atherosclerotic coronary artery disease has evolved considerably since its inception. Though Drug-Eluting Stent (DES) reduces the rate of restenosis, long-term safety outcomes and persistent restenosis in complex lesion subset remain area of concern. Recently, Drug-Eluting Balloon (DEB) represents a novel treatment strategy for atherosclerotic coronary artery disease. DEB demonstrated its added value in preclinical studies. Inspired by these results, several clinical trials particularly in complex lesion subsets have been started to explore the value of this novel treatment strategy in a broader range of lesions. This review would summarise material compositions and different characteristics and clinical outcomes of currently available DEB. PMID:28764234
Biomimicry, vascular restenosis and coronary stents.
Schwartz, R S; van der Giessen, W J; Holmes, D R
1998-01-01
Biomimicry is in its earliest stages and is being considered in the realm of tissue engineering. If arterial implants are to limit neointimal thickening, purely passive structures cannot succeed. Bioactivity must be present, either by pharmacologic intervention or by fabricating a 'living stent' that contains active cellular material. As tissue engineering evolves, useful solutions will emerge from applying this knowledge directly to vascular biologic problems resulting from angioplasty, stenting, and vascular prosthesis research.
Währborg, Peter; Booth, Jean E; Clayton, Tim; Nugara, Fiona; Pepper, John; Weintraub, William S; Sigwart, Ulrich; Stables, Rod H
2004-11-30
Coronary artery bypass surgery (CABG) has been associated with a range of neurological and neuropsychological complications from stroke to cognitive problems such as memory and problem solving disturbance. However, little is known about the impact of percutaneous coronary intervention (PCI) on neuropsychological outcome. In the Stent or Surgery Trial (SoS), 988 patients were randomized in equal proportions between PCI supported by stent implantation and CABG. As a substudy of this trial, we undertook an evaluation of neurological and neuropsychological outcomes after intervention. A clinical examination and neuropsychological assessment consisting of 5 tests (Digit Span Forwards and Backwards, Visual Reproduction, Bourdon, and Block Design) were performed at baseline and 6 and 12 months after the procedure. A total of 145 patients were included in the substudy analysis: 77 in the PCI group and 68 in the CABG group. One patient in the PCI arm had a stroke. There was no significant difference between treatment groups at 6 and 12 months for any of the 5 tests. The mean change from baseline was also similar in both groups. We were not able to demonstrate an important and significant difference in neuropsychological outcome in patients treated with different revascularization strategies. This important finding needs to be examined in further research.
Yang, Yue-jin; Xu, Bo; Kang, Sheng; Pei, Wei-dong; Chen, Ji-lin; Qiao, Shu-bin; Qin, Xue-wen; Yao, Min; Chen, Jue; Wu, Yong-jian; Liu, Hai-Bo; You, Shi-Jie; Li, Jian-Jun; Dai, Jun; Gao, Run-Lin
2007-11-05
The sirolimus and paclitaxel distribution patterns and tissue residence time may be modified in atherosclerotic lesions for patients with diabetes, and the biological mechanisms of action for these agents differ significantly. Previous clinical trials have yielded discrepant results of major adverse cardiac events and restenosis between a sirolimus-eluting stent and a paclitaxel-eluting stent in coronary artery disease. Therefore, this study was conducted to compare in-hospital and long-term clinical outcomes between patients receiving sirolimus-eluting stent (Cypher or Cypher Select stent) and paclitaxel-eluting stent (Taxus Express stent) after percutaneous intervention (PCI) in Chinese patients with diabetes. One hundred and sixty-four consecutive diabetic patients underwent PCI in Fuwai Hospital from April 2004 to December 2004. Of them, 101 patients received Cypher or Cypher Select stents (Cypher group, 145 stents) and 63 patients received Taxus Express stents (Taxus group, 129 stents). Repeat coronary angiography was performed at 6-month and clinical outcomes were evaluated at 1- and 3-year follow-up. Stent thrombosis was classified according to Academic Research Consortium (ARC). The two groups did not differ significantly with respect to cardiac death, recurrent myocardial infarction (re-MI), target vessel revascularization (TVR) and occurrence of major adverse cardiac events (MACE). And the MACE-free cumulative survival at 1- and 3-year follow-up and early, late and very late thrombosis rates were also similar in the two groups (all P > 0.05). There was a trend favoring PES over SES with regard to reducing cardiac death (0 vs 2.0%, P = 0.524), re-MI (0 vs 2.0%, P = 0.524), the composite of the cardiac death and re-MI (0 vs 4.0%, P = 0.299) and very late thrombosis (0 vs 3.0%, P = 0.295) between 1-year and 3-year follow-up. The study indicates that PCI with either Cypher or Taxus stents is associated with similar efficacy and safety in the small population of Chinese diabetic patients during long-term follow-up.
Kolandaivelu, Kumaran; Bailey, Lynn; Buzzi, Stefano; Zucker, Arik; Milleret, Vincent; Ziogas, Algirdas; Ehrbar, Martin; Khattab, Ahmed A; Stanley, James R L; Wong, Gee K; Zani, Brett; Markham, Peter M; Tzafriri, Abraham R; Bhatt, Deepak L; Edelman, Elazer R
2017-04-20
Simple surface modifications can enhance coronary stent performance. Ultra-hydrophilic surface (UHS) treatment of contemporary bare metal stents (BMS) was assessed in vivo to verify whether such stents can provide long-term efficacy comparable to second-generation drug-eluting stents (DES) while promoting healing comparably to BMS. UHS-treated BMS, untreated BMS and corresponding DES were tested for three commercial platforms. A thirty-day and a 90-day porcine coronary model were used to characterise late tissue response. Three-day porcine coronary and seven-day rabbit iliac models were used for early healing assessment. In porcine coronary arteries, hydrophilic treatment reduced intimal hyperplasia relative to the BMS and corresponding DES platforms (1.5-fold to threefold reduction in 30-day angiographic and histological stenosis; p<0.04). Endothelialisation was similar on UHS-treated BMS and untreated BMS, both in swine and rabbit models, and lower on DES. Elevation in thrombotic indices was infrequent (never observed with UHS, rare with BMS, most often with DES), but, when present, correlated with reduced endothelialisation (p<0.01). Ultra-hydrophilic surface treatment of contemporary stents conferred good healing while moderating neointimal and thrombotic responses. Such surfaces may offer safe alternatives to DES, particularly when rapid healing and short dual antiplatelet therapy (DAPT) are crucial.
Gaglia, Michael A; Torguson, Rebecca; Lipinski, Michael J; Gai, Jiaxiang; Koifman, Edward; Kiramijyan, Sarkis; Negi, Smita; Rogers, Toby; Steinvil, Arie; Suddath, William O; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron
2016-02-15
Although metallic coronary stents significantly reduce angina pectoris compared with optimal medical therapy, angina after percutaneous coronary intervention (PCI) remains frequent. We, therefore, sought to compare the incidence of any angina during the 1 year after PCI among the spectrum of commercially available metallic stents. Metallic stent type was classified as bare metal stent, Cypher, Taxus Express, Xience V, Promus Element, and Resolute. The primary end point was patient-reported angina within 1 year of PCI. Multivariable logistic regression was performed to assess the independent association of stent type with any angina at 1 year. Overall, 8,804 patients were queried in regard to angina symptoms; 32.3% experienced angina at some point in the first year after PCI. Major adverse cardiovascular events, a composite of all-cause mortality, target vessel revascularization, and Q-wave myocardial infarction, increased with angina severity: 6.8% for patients without angina, 10.0% for patients with class 1 or 2 angina, and 19.7% for patients with class 3 or 4 angina (p <0.001 for trend). After multivariable adjustment, there was no significant association between stent type and angina at 1 year after PCI. Baseline Canadian Cardiovascular Society class 3 or 4 angina, history of coronary artery bypass grafting, and history of PCI were associated with a higher likelihood of angina at 1 year; increasing age, male gender, presentation with acute coronary syndrome, and higher stented length were associated with less angina. In conclusion, metallic stent type is not associated with the occurrence of angina at up to 1 year after PCI. Copyright © 2016 Elsevier Inc. All rights reserved.
Chandwani, Prakash; Prajapati, Jayesh; Porwal, Sanjay; Khambhati, Bhavesh; Thakkar, Ashok
2015-02-01
Coronary artery disease is the most common catastrophic disease in India. The safety and effectiveness of dual vessel sirolimus-eluting stent (SES) implantation (used as an intervention in CAD) is currently unknown in Indian population. The purpose of this study was to investigate one year clinical outcomes of patients with dual vessel coronary artery disease after implantation of the Supralimus-Core SES, in a "real-world" setting. We evaluated 60 patients between April-2011 and August-2012, who underwent dual vessel percutaneous coronary intervention (PCI) with the Supralimus-Core SES implantation at the same index procedure. Dual vessels were defined as involvement of two major epicardial vessels (right, left anterior descending, circumflex, or left main coronary arteries) or one major epicardial vessel and a branch (≥2.5 mm in diameter) originating from another major epicardial vessel. The primary endpoint was target lesion failure (TLF) defined as the composite of cardiac death, myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR) at one year. Secondary endpoint included combined (definite, probable and possible) stent thrombosis (ST). A total of 120 lesions were treated in 60 enrolled patients (mean age 56.0±9.2 y; 80.0% male) with average stent length of 23.1±8.5 mm. Among 60 patients, diabetes, hypertension and hypercholesterolemia were present in 15 (25.0%), 22 (36.7%) and 25 (41.7%) patients respectively. Indications for PCI were unstable angina in 30 (50.0%) patients and stable angina in 11 (18.3%) patients. Overall, 40 (33.3%) lesions were classified as complex (American College of Cardiology/American Heart Association type B2/C). The cumulative TLF rate was 5.0% (n=3) at one year. Cardiac death, MI and clinically-driven TLR occurred in 1 (1.7%), 0 (0%) and 2 (3.3%) patients, respectively at one year follow-up. The Kaplan-Meier curve of the freedom from overall events at one year was 95.0%. According to the Academic Research Consortium definition, there were no events of stent thrombosis during one year. Our study shows that, dual vessel Supralimus-Core SES implantation allows safe and effective treatment with low rates of TLF at one year follow-up in Indian population.
A unique and unexplained ricochet leak post PCI - successfully treated with intra-coronary glue.
Goel, Pravin K; Syal, Sanjeev K
2014-01-01
We herein describe a unique case of coronary artery perforation treated with covered stent with repeat cardiac tamponade resulting out of a fresh unexplained leak from a remote vessel (Ricochet) and successfully treated with intra-coronary injection of sterile synthetic glue, cyanoacrylate. Copyright © 2014 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.
Shlofmitz, Evan; Martinsen, Brad J; Lee, Michael; Rao, Sunil V; Généreux, Philippe; Higgins, Joe; Chambers, Jeffrey W; Kirtane, Ajay J; Brilakis, Emmanouil S; Kandzari, David E; Sharma, Samin K; Shlofmitz, Richard
2017-11-01
The presence of severe coronary artery calcification is associated with higher rates of angiographic complications during percutaneous coronary intervention (PCI), as well as higher major adverse cardiac events compared with non-calcified lesions. Incorporating orbital atherectomy (OAS) for effective preparation of severely calcified lesions can help maximize the benefits of PCI by attaining maximal luminal gain (or stent expansion) and improve long-term outcomes (by reducing need for revascularization). Areas covered: In this manuscript, the prevalence, risk factors, and impact of coronary artery calcification on PCI are reviewed. Based on current data and experience, the authors review orbital atherectomy technique and best practices to optimize lesion preparation. Expert Commentary: The coronary OAS is the only device approved for use in the U.S. as a treatment for de novo, severely calcified coronary lesions to facilitate stent delivery. Advantages of the device include its ease of use and a mechanism of action that treats bi-directionally, allowing for continuous blood flow during treatment, minimizing heat damage, slow flow, and subsequent need for revascularization. The OAS technique tips reviewed in this article will help inform interventional cardiologists treating patients with severely calcified lesions.
Fry, James; Naqvi, Ali; Bahia, Amit; Seto, Arnold
2017-03-01
A 52-year-old Asian male with no traditional risk factors for coronary artery disease presented with acute coronary syndrome. Coronary angiography showed complete thrombotic occlusion of the left circumflex with a large thrombus burden in the setting of diffuse aneurysmal enlargement of the coronary arteries consistent with antecedent Kawasaki disease. Manual thrombectomy with adjunctive intracoronary tirofiban was performed utilizing the GuideLiner catheter ® (Vascular Solutions, Inc., MN, USA). Stent implantation was deferred. Follow-up imaging 48 h later showed preserved coronary flow and decreased thrombus burden. The GuideLiner catheter, a monorail guiding device, served a novel role in thrombus aspiration and intracoronary medication delivery.
Harjai, Kishore J; Samy, Sanjay; Pennypacker, Barbara; Onofre, Bonnie; Stanfield, Pamela; Yaeger, Lynne; Stapleton, Dwight; Esrig, Barry C
2012-12-01
Hybrid coronary revascularization, which involves minimally invasive direct coronary artery bypass surgery using the left internal mammary artery to left anterior descending and percutaneous coronary intervention using drug-eluting stents for the remaining diseased coronary vessels, is an innovative approach to decrease the morbidity of conventional surgery. Little information is available to guide hospital managers and physician leaders in implementing a hybrid revascularization program. In this article, we describe the people-process-technology issues that managers and leaders are likely to encounter as they develop a hybrid revascularization program in their practice. ©2012, Wiley Periodicals, Inc.
Zhang, Xin-Lin; Zhu, Qing-Qing; Yang, Jing-Jing; Chen, Yu-Han; Li, Yang; Zhu, Su-Hui; Xie, Jun; Wang, Lian; Kang, Li-Na; Xu, Biao
2017-04-21
The optimal revascularization technique in patients with left main coronary artery disease (CAD) remains controversial. We aimed to compare the long-term performance of percutaneous coronary intervention (PCI) versus coronary artery bypass graft (CABG) surgery in treatment of left main CAD. PubMed, EMBASE, and the Cochrane Library were searched until November 16, 2016. Six randomized controlled trials and 22 matched observational studies including 22,487 patients and 90,167 patient-years of follow-up were included. PCI was associated with an overall higher risk for the major adverse cardiac and cerebrovascular events (hazard ratio (HR), 1.42; 95% confidence interval (CI), 1.14-1.77), mainly driven by higher rates of myocardial infarction (HR, 1.69; 95% CI, 1.22-2.34) and revascularization (HR, 2.80; 95% CI, 1.86-4.22). The overall risks for all-cause death (HR, 1.05; 95% CI, 0.93-1.20), cardiac death (HR, 1.05; 95% CI, 0.69-1.59), stroke (HR, 0.64; 95% CI, 0.33-1.24), and the composite safety endpoint of death, myocardial infarction, or stroke (HR, 1.06; 95% CI, 0.97-1.16) were similar between PCI and CABG. Stratified analysis based on stent types showed that the increased risk for myocardial infarction associated with PCI was only evident in patients with bare-metal stents or early-generation drug-eluting stents (DES), but not newer-generation DES. Stratified analyses based on study designs showed largely similar findings with the overall analyses, except for a significantly higher incidence of myocardial infarction in adjusted studies (HR, 2.01; 95% CI, 1.64-2.45) but a trend toward higher incidence in randomized trials (HR, 1.39; 95% CI, 0.85-2.27) associated with PCI. Compared with CABG, PCI with newer-generation DES might be a safe alternative revascularization strategy for treatment of left main CAD, but is associated with more repeat revascularization.
Exercise-induced ST-segment elevation during treadmill exercise testing.
Patanè, Salvatore; Marte, Filippo
2010-09-03
The exercise electrocardiogram is a commonly used non-invasive and inexpensive method for detection of electrocardiogram (ECG) changes secondary to myocardial ischemia. It has been reported that in patients with a first myocardial infarction and without residual ischemia, exercise-induced ST-segment elevation in Q leads is related to a more damaged coronary microcirculation and to less viable myocardium. Exercise-induced ST-segment elevation is a rare phenomenon in patients without prior myocardial infarction. When occurring purely during exercise, coronary lesions are frequent and often severe, and on the other hand ST-segment elevation of the recovery phase is frequently associated with normal arteries or less severe lesions. We present a case of exercise-induced ST-segment elevation in a 51-year-old Italian man. Coronary angiography revealed a significant left anterior descending coronary artery stenosis, a significant circumflex coronary artery stenosis, a significant first obtuse marginal coronary artery stenosis and a significant second obtuse marginal coronary artery stenosis. Percutaneous transluminal coronary angioplasty with implantation of stents was successfully performed. Also this case is illustrative of the rare phenomenon of exercise-induced ST-segment elevation. Copyright © 2008 Elsevier B.V. All rights reserved.
Arokiaraj, Mark Christopher
2018-02-01
Difficulty in engaging with guide catheters is not uncommon in acute emergencies. We aimed to evaluate the use of Cordis ® INFINITI diagnostic catheters to perform angioplasty in patients in whom the coronaries cannot be engaged using standard guide catheters. In 34 cases of acute coronary syndrome, when difficulty in engagement with two standard guide catheters was encountered with reasonable manipulations, angioplasty was performed using diagnostic catheters. In total, 40 stents were placed by this technique. Pushability and trackability, distal tip flexion and three-point bending tests were performed to evaluate the performance of the guide and diagnostic catheters. Angioplasty was performed easily in a setting where it would have been very difficult to perform. Coronary dissection occurred in one patient, treated by a stent. The stent and dilatation balloons were easily passed through the diagnostic catheters. Pressure tracings were clearly preserved with certain stent delivery systems, and at angioplasty, although there was slightly reduced opacification of the respective artery, the coronary anatomy was sufficiently visualized to perform angioplasty. No periprocedural target lesion complications were seen in any cases. Pushability and trackability tests showed good force transmission along a tortuous path with diagnostic catheters, and balanced force-displacement curves from three-point bending tests and distal tip softness tests. Angioplasty with stenting can be performed safely through 6F Cordis ® infiniti diagnostic catheters when difficulty in engaging guide catheters is encountered. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
Shiomi, Hiroki; Yamaji, Kyohei; Morimoto, Takeshi; Shizuta, Satoshi; Nakatsuma, Kenji; Higami, Hirooki; Furukawa, Yutaka; Nakagawa, Yoshihisa; Kadota, Kazushige; Ando, Kenji; Sakata, Ryuzo; Okabayashi, Hitoshi; Hanyu, Michiya; Shimamoto, Mitsuomi; Nishiwaki, Noboru; Komiya, Tatsuhiko; Kimura, Takeshi
2016-08-01
Many of the previous randomized trials comparing percutaneous coronary intervention (PCI) with coronary artery bypass grafting (CABG) in patients with multivessel coronary artery disease reported equivalent or better survival with CABG as compared with PCI at 5-year follow-up. However, 5-year follow-up might be too short to evaluate the true differences in long-term clinical outcomes between PCI and CABG. Among 8934 patients enrolled in the extended 10- to 14-year follow-up study of the CREDO-Kyoto registry cohort-1 (Coronary Revascularization Demonstrating Outcome study in Kyoto) conducted in the bare-metal stent era, 5152 (PCI: n=3490 and CABG: n=1662) patients had multivessel coronary artery disease without left main disease. Median follow-up duration was 11.2 (interquartile range: 10.2-12.2) years. The cumulative 10-year incidence of all-cause death was not significantly different between PCI and CABG (32.2% versus 31.7%; log-rank P=0.93). After adjusting for confounders, however, the mortality risk of PCI was significantly higher than that of CABG (hazard ratio, 1.19 [95% confidence interval, 1.02-1.39]; P=0.03). Within 5 years after the index procedure, the risk for all-cause death was significantly higher after PCI than after CABG (hazard ratio, 1.41; 95% CI, 1.12-1.79; P=0.004). By a landmark analysis at 5 years, however, the cumulative 10-year incidence of and adjusted risk for all-cause death beyond 5 years were not significantly different between PCI and CABG (19.3% versus 20.0%; log-rank P=0.22 and hazard ratio, 1.02, 95% confidence interval, 0.83-1.26; P=0.82). CABG as compared with PCI was associated with better 10-year survival in patients with multivessel coronary artery disease. However, the benefit of CABG compared with PCI on late mortality beyond 5 years was not observed in this study. © 2016 American Heart Association, Inc.
Wan, You-Dong; Sun, Tong-Wen; Kan, Quan-Cheng; Guan, Fang-Xia; Liu, Zi-Qi; Zhang, Shu-Guang
2016-01-01
Background Intra-aortic balloon pumps (IABP) have generally been used for patients undergoing high-risk mechanical coronary revascularization. However, there is still insufficient evidence to determine whether they can improve outcomes in reperfusion therapy patients, mainly by percutaneous coronary intervention (PCI) with stenting or coronary artery bypass graft (CABG). This study was designed to determine the difference between high-risk mechanical coronary revascularization with and without IABPs on mortality, by performing a meta-analysis on randomized controlled trials of the current era. Methods Pubmed and Embase databases were searched from inception to May 2015. Unpublished data were obtained from the investigators. Randomized clinical trials of IABP and non-IABP in high-risk coronary revascularization procedures (PCI or CABG) were included. In the case of PCI procedures, stents should be used in more than 80% of patients. Numbers of events at the short-term and long-term follow-up were extracted. Results A total of 12 randomized trials enrolling 2155 patients were included. IABPs did not significantly decrease short-term mortality (relative risk (RR) 0.66; 95% CI, 0.42–1.01), or long-term mortality (RR 0.79; 95% CI, 0.47–1.35), with low heterogeneity across the studies. The findings remained stable in patients with acute myocardial infarction with or without cardiogenic shock. But in high-risk CABG patients, IABP was associated with reduced mortality (71 events in 846 patients; RR 0.40; 95%CI 0.25–0.67). Conclusion In patients undergoing high-risk coronary revascularization, IABP did not significantly decrease mortality. But high-risk CABG patients may be benefit from IABP. Rigorous criteria should be applied to the use of IABPs. PMID:26784578
Grines, Cindy L; Bonow, Robert O; Casey, Donald E; Gardner, Timothy J; Lockhart, Peter B; Moliterno, David J; O'Gara, Patrick; Whitlow, Patrick
2007-02-13
Dual antiplatelet therapy with aspirin and a thienopyridine has been shown to reduce cardiac events after coronary stenting. However, many patients and healthcare providers prematurely discontinue dual antiplatelet therapy, which greatly increases the risk of stent thrombosis, myocardial infarction, and death. This advisory stresses the importance of 12 months of dual antiplatelet therapy after placement of a drug-eluting stent and educating the patient and healthcare providers about hazards of premature discontinuation. It also recommends postponing elective surgery for 1 year, and if surgery cannot be deferred, considering the continuation of aspirin during the perioperative period in high-risk patients with drug-eluting stents.
Grines, Cindy L; Bonow, Robert O; Casey, Donald E; Gardner, Timothy J; Lockhart, Peter B; Moliterno, David J; O'Gara, Patrick; Whitlow, Patrick
2007-05-01
and Overview. Dual antiplatelet therapy with aspirin and a thienopyridine has been shown to reduce cardiac events after coronary stenting. However, many patients and health care providers prematurely discontinue dual antiplatelet therapy, which greatly increases the risk of stent thrombosis, myocardial infarction and death. This advisory stresses the importance of 12 months of dual antiplatelet therapy after placement of a drug-eluting stent and educating patients and health care providers about hazards of premature discontinuation. It also recommends postponing elective surgery for one year, and if surgery cannot be deferred, considering the continuation of aspirin during the perioperative period in high-risk patients with drug-eluting stents.
First-in-man study of simvastatin-eluting stent in de novo coronary lesions: the SIMVASTENT study.
Zago, Alexandre C; Matte, Bruno S; Reginato, Luciana; Iturry-Yamamoto, Germán; Krepsky, Ana; Bergoli, Luiz Carlos C; Balvedi, Julise; Raudales, José C; Saadi, Eduardo K; Zago, Alcides J
2012-01-01
Statins have anti-inflammatory and antiproliferative properties irrespective of their cholesterol-lowering effects. The aim of the present study was to evaluate a simvastatin-eluting stent (SimvES) in the treatment of de novo coronary lesions. Forty-two patients with de novo coronary artery lesions were assigned to SimvES, bare-metal stent (BMS) or everolimus-eluting stent (EES) implantation followed by intravascular ultrasound (IVUS) for neointimal quantitative analysis. Six months later, quantitative coronary angiography (QCA) and IVUS were repeated. QCA showed no binary restenosis, a mean in-stent late loss of 1.05 ± 0.25 mm (BMS, 1.12 ± 0.48 mm; EES, 0.20 ± 0.16 mm) and a diameter stenosis of 33.5 ± 7.1% (BMS, 35.5 ± 15.30%; EES, 7.2 ± 3.12%). Control IVUS showed a mean in-stent obstruction of 18.3 ± 9.4% (BMS, 32.8 ± 19.1%; EES, 9.8 ± 2.4%) and a neointimal volume index of 1.58 ± 0.75 mm(3)/mm (BMS, 2.93 ± 1.76 mm(3)/mm; EES, 0.80 ± 0.16 mm(3)/mm). Thrombus, late incomplete apposition and major adverse cardiac events were not observed. In this sample of patients with de novo coronary lesions, the use of a SimvES was not related to major adverse cardiac events, but it was associated with a higher level of neointimal proliferation than expected.
Schnorbus, Boris; Daiber, Andreas; Jurk, Kerstin; Warnke, Silke; König, Jochem; Krahn, Ulrike; Lackner, Karl; Munzel, Thomas; Gori, Tommaso
2014-01-01
Introduction Particularly in the setting of acute coronary syndromes, the interplay between vascular and platelet function has been postulated to have direct clinical implications. The present trial is designed to test the effect of clopidogrel, prasugrel and ticagrelor on multiple parameters of vascular function, platelet aggregation, oxidative and inflammatory stress before and up to 4 weeks after coronary artery stenting. Methods and analysis The study is designed as a three-arm, parallel design, randomised, investigator-blinded study. Patients with unstable angina or non-ST elevation myocardial infarction undergoing coronary intervention with a drug-eluting stent will be randomised to receive 600 mg clopidogrel, 60 mg prasugrel or 180 mg ticagrelor followed by oral therapy with the same drug. The primary endpoint of the trial is the impact of antiplatelet treatments on endothelial function as assessed by flow-mediated dilation at 1 day, 1 week and 1 month in patients who have undergone stenting. Secondary endpoints include the impact of study medications on parameters of macrovascular and microvascular function, platelet reactivity, oxidative and inflammatory stress. The study recruitment is currently ongoing and, after an interim analysis which was performed at 50% of the initially planned population, it is planned to continue until July 2015. Ethics and dissemination The protocol was approved by the local ethics committee. The trial will provide important pathophysiological insight on the relationship between platelet aggregation and endothelial function, two parameters that have been shown to influence patients’ prognosis. Trial registration number ClinicalTrials.gov Identifier: NCT01700322; EudraCT-Nr.: 2011-005305-73. Current V.1.3, from 24 February 2014. PMID:24801283
Does grafting coronary arteries with only moderate stenosis affect long-term mortality?
Sabik, Joseph F.; Olivares, Gabriel; Raza, Sajjad; Lytle, Bruce W.; Houghtaling, Penny L.; Blackstone, Eugene H.
2016-01-01
Objective Stenting coronary arteries with non–ischemia-producing moderate stenosis leads to worse outcomes than leaving them unstented. We sought to determine whether grafting coronary arteries with angiographically moderate stenosis is associated with worse long-term survival than leaving them ungrafted. Methods From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 8531 had a single coronary artery with moderate (50%-69%) stenosis, bypassed in 6598 (77%) and not bypassed in 1933 (23%). These arteries were grafted with internal thoracic arteries (ITAs) in 1806 patients (27%) and with saphenous veins (SVs) in 4625 (70%). Mean follow-up for all-cause mortality was 13.0 ± 9.7 years. Results Survival was similar for patients with and without a graft to the moderately stenosed coronary artery (P = .3): 97%, 76%, 43%, and 18% at 1, 10, 20, and 30 years among patients receiving no graft; 97%, 74%, 41%, and 18% among those receiving an SV graft; and 98%, 82%, 51%, and 23% among those receiving an ITA graft. After adjusting for patient characteristics, SV grafting versus nongrafting of moderately stenosed coronary arteries was associated with similar long-term mortality (P = .2), whereas ITA grafting was associated with 22% lower long-term mortality (hazard ratio 0.78; 68% confidence interval 0.75–0.82; P<.0001). Conclusions Grafting coronary arteries with angiographically moderate stenosis is not harmful. Instead, ITA grafting of such coronary arteries is associated with lower long-term mortality. Thus, after placing the first ITA to the left anterior descending, the second ITA should be placed to the second most important coronary artery, even if it is moderately stenosed. PMID:26611750
Does grafting coronary arteries with only moderate stenosis affect long-term mortality?
Sabik, Joseph F; Olivares, Gabriel; Raza, Sajjad; Lytle, Bruce W; Houghtaling, Penny L; Blackstone, Eugene H
2016-03-01
Stenting coronary arteries with non-ischemia-producing moderate stenosis leads to worse outcomes than leaving them unstented. We sought to determine whether grafting coronary arteries with angiographically moderate stenosis is associated with worse long-term survival than leaving them ungrafted. From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 8531 had a single coronary artery with moderate (50%-69%) stenosis, bypassed in 6598 (77%) and not bypassed in 1933 (23%). These arteries were grafted with internal thoracic arteries (ITAs) in 1806 patients (27%) and with saphenous veins (SVs) in 4625 (70%). Mean follow-up for all-cause mortality was 13.0 ± 9.7 years. Survival was similar for patients with and without a graft to the moderately stenosed coronary artery (P = .3): 97%, 76%, 43%, and 18% at 1, 10, 20, and 30 years among patients receiving no graft; 97%, 74%, 41%, and 18% among those receiving an SV graft; and 98%, 82%, 51%, and 23% among those receiving an ITA graft. After adjusting for patient characteristics, SV grafting versus nongrafting of moderately stenosed coronary arteries was associated with similar long-term mortality (P = .2), whereas ITA grafting was associated with 22% lower long-term mortality (hazard ratio 0.78; 68% confidence interval 0.75-0.82; P < .0001). Grafting coronary arteries with angiographically moderate stenosis is not harmful. Instead, ITA grafting of such coronary arteries is associated with lower long-term mortality. Thus, after placing the first ITA to the left anterior descending, the second ITA should be placed to the second most important coronary artery, even if it is moderately stenosed. Copyright © 2016. Published by Elsevier Inc.
Zhang, Fan; Tongo, Nosakhare Douglas; Hastings, Victoria; Kanzali, Parisa; Zhu, Ziqiang; Chadow, Hal; Rafii, Shahrokh E.
2017-01-01
Patient: Male, 51 Final Diagnosis: ST-segment elevation myocardial infarction with acute stent thrombosis Symptoms: Chest pain • hiccups Medication: — Clinical Procedure: — Specialty: Cardiology Objective: Unusual clinical course Background: Acute coronary syndrome (ACS) can present with atypical chest pain or symptoms not attributed to heart disease, such as indigestion. Hiccups, a benign and self-limited condition, can become persistent or intractable with overlooked underlying etiology. There are various causes of protracted hiccups, including metabolic abnormalities, psychogenic disorders, malignancy, central nervous system pathology, medications, pulmonary disorders, or gastrointestinal etiologies. It is rarely attributed to cardiac disease. Case Report: We report a case of intractable hiccups in a 51-year-old male with cocaine related myocardial infarction (MI) before and after stent placement. Coronary angiogram showed in-stent thrombosis of the initial intervention. Following thrombectomy, balloon angioplasty, and stent, the patient recovered well without additional episodes of hiccups. Although hiccups are not known to present with a predilection for a particular cause of myocardial ischemia, this case may additionally be explained by the sympathomimetic effects of cocaine, which lead to vasoconstriction of coronary arteries. Conclusions: Hiccups associated with cardiac enzyme elevation and EKG ST-segment elevation before and after percutaneous coronary intervention (PCI) maybe a manifestation of acute MI with or without stent. The fact that this patient was a cocaine user may have contributed to the unique presentation. PMID:28455489
Suwannasom, Pannipa; Sotomi, Yohei; Ishibashi, Yuki; Cavalcante, Rafael; Albuquerque, Felipe N; Macaya, Carlos; Ormiston, John A; Hill, Jonathan; Lang, Irene M; Egred, Mohaned; Fajadet, Jean; Lesiak, Maciej; Tijssen, Jan G; Wykrzykowska, Joanna J; de Winter, Robbert J; Chevalier, Bernard; Serruys, Patrick W; Onuma, Yoshinobu
2016-06-27
The study sought to investigate the relationship between post-procedural asymmetry, expansion, and eccentricity indices of metallic everolimus-eluting stent (EES) and bioresorbable vascular scaffold (BVS) and their respective impact on clinical events at 1-year follow-up. Mechanical properties of a fully BVS are inherently different from those of permanent metallic stent. The ABSORB II (A bioresorbable everolimus-eluting scaffold versus a metallic everolimus-eluting stent for ischaemic heart disease caused by de-novo native coronary artery lesions) trial compared the BVS and metallic EES in the treatment of a de novo coronary artery stenosis. Protocol-mandated intravascular ultrasound imaging was performed pre- and post-procedure in 470 patients (162 metallic EES and 308 BVS). Asymmetry index (AI) was calculated per lesion as: (1 - minimum scaffold/stent diameter/maximum scaffold/stent diameter). Expansion index and optimal scaffold/stent expansion followed the definition of the MUSIC (Multicenter Ultrasound Stenting in Coronaries) study. Eccentricity index (EI) was calculated as the ratio of minimum and maximum scaffold/stent diameter per cross section. The incidence of device-oriented composite endpoint (DoCE) was collected. Post-procedure, the metallic EES group was more symmetric and concentric than the BVS group. Only 8.0% of the BVS arm and 20.0% of the metallic EES arm achieved optimal scaffold/stent expansion (p < 0.001). At 1 year, there was no difference in the DoCE between both devices (BVS 5.2% vs. EES 3.1%; p = 0.29). Post-procedural devices asymmetry and eccentricity were related to higher event rates while there was no relevance to the expansion status. Subsequent multivariate analysis identified that post-procedural AI >0.30 is an independent predictor of DoCE (hazard ratio: 3.43; 95% confidence interval: 1.08 to 10.92; p = 0.037). BVS implantation is more frequently associated with post-procedural asymmetric and eccentric morphology compared to metallic EES. Post-procedural devices asymmetry were independently associated with DoCE following percutaneous coronary intervention. However, this approach should be viewed as hypothesis generating due to low event rates. (ABSORB II Randomized Controlled Trial [ABSORB II]; NCT01425281). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Sarma, Raghava; Prajapati, Jayesh; Raheem, Asif; Thakkar, Kamlesh; Kothari, Shivani; Thakkar, Ashok
2015-08-01
The main culprit in first-generation drug eluting stents is 'durable' polymer, whose continuous presence may impair arterial healing and ultimately have a negative impact on late outcomes. The main enigma behind the biodegradable polymer usage is its degradation after elution of drug. This reduces adverse events in unselected patients with complex coronary artery lesions treated with biodegradable polymer coated sirolimus-eluting stents. The aim of the INDOLIMUS-G Registry was to evaluate safety and efficacy of the Indolimus (Sahajanand Medical Technologies Pvt. Ltd., Surat, India) sirolimus-eluting stents in large cohorts of unselected patients with complex coronary artery lesions. It is a multi-centre, non-randomized retrospective registry with a clear aim of evaluating safety and efficacy of the Indolimus sirolimus-eluting stents in consecutive patients enrolled between April 2012 and May 2014. The primary end-point of the study was major adverse cardiac events (MACE), which is a composite of cardiac death, myocardial infarction (MI), target lesion revascularization (TLR), target vessel revascularization (TVR) and stent thrombosis (ST) at the end of follow-up. Clinical follow-up were scheduled at the end of 30-days, 6-months, and 9-months period. The mean age of enrolled patients was 52.6 ± 11.0 years. A total of 1137 lesions were intervened successfully with 1242 stents (1.09 ± 0.30 stent per lesion). The average stent length and diameter was 27.42 ± 9.01 mm and 3.12 ± 0.36 mm respectively. There were 740 (73.40%) male patients, indicating their high prevalence. Diabetes, hypertension and totally occluded lesions were found in 372 (36.90%), 408 (40.47%) and 170 (16.86%) patients, respectively. This showed that study also included high risk complex lesions and not ideal recruited lesions. The incidence of MACE at 30-days, 6-months and 9-months were 3 (0.30%), 18 (1.80%) and 22 (2.20%) respectively. At 9-months, TLR was found in 6 (0.50%) patients. There were 2 (0.20%) cases of ST, 10 (1.0%) cases of MI and 4 (0.40%) cases of cardiac death at 9-month follow-up. The lower incidence of MACE, TLR and ST at 9-month follow-up clearly delineates safety and efficacy of Indolimus SES in large cohorts of unselected patients with complex coronary lesions.
The History of Primary Angioplasty and Stenting for Acute Myocardial Infarction.
Smilowitz, Nathaniel R; Feit, Frederick
2016-01-01
The evolution of the management of acute myocardial infarction (MI) has been one of the crowning achievements of modern medicine. At the turn of the twentieth century, MI was an often-fatal condition. Prolonged bed rest served as the principal treatment modality. Over the past century, insights into the pathophysiology of MI revolutionized approaches to management, with the sequential use of surgical coronary artery revascularization, thrombolytic therapy, and percutaneous coronary intervention (PCI) with primary coronary angioplasty, and placement of intracoronary stents. The benefits of prompt revascularization inspired systems of care to provide rapid access to PCI. This review provides a historical context for our current approach to primary PCI for acute MI.
Schalij, M J; Udayachalerm, W; Oemrawsingh, P; Jukema, J W; Reiber, J H; Bruschke, A V
1999-09-01
To evaluate the results of long Micro Stent II (MS-XL) implantations, 119 MS-XLs were implanted in 102 patients (age, 62.83 years). Nineteen stents (16%) were implanted in saphenous vein grafts; 100 stents (84%) were implanted in native coronary arteries. Twenty-five patients (25%) were treated because of acute myocardial infarction (AMI); 30 patients (29%) because of unstable angina or angina class IV, and 47 patients (46%) because of stable angina. Eighty-six de novo lesions (84%) and 16 restenotic lesions (16%) were treated. Indications for stent implantation include elective, 61 patients (60%); suboptimal balloon angioplasty result, 22 patients (21%); and bailout after balloon angioplasty, 19 patients (19%). Because of residual thrombus after stenting, 27 patients (26%) received abciximab. All patients received ticlopidin for 28 days and acetylsalicylic acid. One hundred and seventeen MS-XLs (98%) were implanted successfully. Additional (shorter) MS-II were implanted in 40 patients (39%). The stented segment length was 45 +/- 20 mm. The minimum lumen diameter increased from 0.5 +/- 0.5 mm before to 2.7 +/- 0.5 mm after stent implantation. The acute gain was 2.2 +/- 0.4 mm. Early clinical events (<4 weeks) include death, 3 (3%); subacute stent thrombosis, 1 (1%); non-Q-wave infarction, 2 (2%); CABG, 1 (1%); vascular complications, 2 (2%). Late clinical events (<6 months) include acute myocardial infarction, 5 (5%); reintervention, 6 (6%); CABG, 1 (1%). The procedural success rate was 88%, and the event free survival at 6 months was 76%. Stenting of long lesions with the MS-XL was successful and associated with an acceptable complication rate. Cathet. Cardiovasc. Intervent. 48:105-112, 1999. Copyright 1999 Wiley-Liss, Inc.
Baron, Suzanne J; Lei, Yang; Chinnakondepalli, Khaja; Vilain, Katherine; Magnuson, Elizabeth A; Kereiakes, Dean J; Ellis, Stephen G; Stone, Gregg W; Cohen, David J
2017-04-24
The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the Xience stent with respect to target lesion failure at 1 year. Whether health care costs differ between the Absorb scaffold and the Xience stent is unknown. We performed a prospective health economic study alongside the ABSORB III trial, in which patients undergoing percutaneous coronary intervention for stable or unstable angina were randomized to receive the Absorb scaffold (n = 1,322) or Xience stent (n = 686). Resource use data were collected through 1 year of follow-up. Costs were assessed using resource-based accounting (for procedures), MedPAR data (for other index hospitalization costs), and Medicare reimbursements (for follow-up costs and physician fees). Initial procedural costs were higher with the Absorb scaffold than the Xience stent ($6,316 ± 1,892 vs. $6,103 ± 1,895; p = 0.02), driven mainly by greater balloon catheter use and the higher cost of the scaffold in the Absorb group. Nonetheless, index hospitalization costs ($15,035 ± 2,992 for Absorb vs. $14,903 ± 3,449 for Xience; p = 0.37) and total 1-year costs ($17,848 ± 6,110 for Absorb vs. $17,498 ± 7,411 for Xience; p = 0.29) were similar between the 2 groups. Although initial procedural costs were higher with the Absorb scaffold, there were no differences in total 1-year health care costs between the 2 cohorts. Longer term follow-up is needed to determine whether meaningful cost savings emerge after scaffold resorption. (A Clinical Evaluation of Absorb™ BVS, the Everolimus-Eluting Bioresorbable Vascular Scaffold in the Treatment of Subjects With de Novo Native Coronary Artery Lesions; NCT01751906). Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Zimarino, Marco; Angeramo, Francesca; Prasad, Abhiram; Ruggieri, Benedetta; Malatesta, Sara; Prati, Francesco; Buttitta, Fiamma; De Caterina, Raffaele
2016-11-01
To test whether thrombus aspiration (TA) reduces the atherosclerotic burden in culprit lesions and "facilitate" percutaneous coronary intervention with stent (S-PCI) among patients with non-ST elevation acute coronary syndromes (NSTE-ACS). Evidence on the effects of TA adjunctive to S-PCI in NSTE-ACS is limited and controversial. TA was defined "aggressive" when using 7F devices or a catheter/artery ratio >0.6, "conservative" with 6F, and a catheter/artery ratio ≤0.6. Angiography and intravascular ultrasound (IVUS) were performed at baseline, after TA and after stent deployment. TA was accomplished in 61/76 patients (80%) with NSTE-ACS. The aspirated material was red thrombus in 23% and plaque fragments in 49% of cases. Compared with baseline, TA was associated with an 82% increase in minimal lumen diameter and a 15% reduction in diameter stenosis (P < 0.001 for both). After TA, IVUS documented a 24 and 16% increase in minimal lumen area and lumen volume, respectively (P < 0.001 for both), a 7% decrease in area stenosis through an 11% reduction of plaque + media volume (P < 0.001). When compared with "conservative", an "aggressive" TA was associated with a more pronounced reduction in percent area stenosis (P < 0.05) and an increase in percent stent expansion (P < 0.001). The plaque + media volume reduction after TA was correlated with stent expansion (r = 0.261, P = 0.046). Manual TA reduces atherothrombotic burden in culprit lesions of NSTE-ACS patients before S-PCI and, when deep plaque removal is obtained, TA optimizes subsequent stent expansion. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Shirota, Ayumi; Nomura, Tetsuya; Kubota, Hiroshi; Taminishi, Shunta; Urata, Ryota; Sugimoto, Takeshi; Higuchi, Yusuke; Kato, Taku; Keira, Natsuya; Tatsumi, Tetsuya
2015-07-28
Because of the unusual anatomy of an anomalous origin of the right coronary artery from the left sinus of Valsalva, selective cannulation of the guiding catheter in percutaneous coronary intervention for these cases is always challenging. A 58-year-old Japanese man was admitted to our hospital complaining of worsening exertional chest pain. He was suspected of having unstable angina pectoris and underwent cardiac catheterization. We found a subtotal occlusive lesion in the mid-portion of his right coronary artery that originated from the left sinus of Valsalva. On the previous percutaneous coronary intervention, we failed to cannulate the guiding catheter to the anomalous orifice of the right coronary artery. Therefore, we decided to use the GuideLiner catheter for stable back-up support from the beginning. A 6Fr GuideLiner catheter was introduced into the right coronary artery by anchoring it coaxially with a semi-compliant balloon catheter. And we successfully deployed two drug-eluting stents by crossing over the posterior-descending artery. Final angiography demonstrated favorable dilatation of the target lesion, and native blood flow in the right coronary artery was completely recovered. GuideLiner is a monorail-type "child" support catheter that facilitates coaxial guiding catheter engagement and an appropriate back-up force, achieving successful device delivery to target lesions in this kind of complex percutaneous coronary intervention.
Pockett, C R; Moore, J W; El-Said, H G
2017-02-01
Adverse events from Melody valve implantation may be catastrophic. To date a role for three dimensional rotational angiography of the aortic root (3DRAA) during Melody valve implantation has not been established. To describe the role of 3DRAA in the assessment of Melody valve candidacy and to demonstrate that it may improve outcomes. All patients who underwent cardiac catheterisation for Melody valve implantation and 3DRAA between August 2013 and February 2015 were reviewed. 31 patients had 3DRAA with balloon sizing. Ten were deemed not Melody candidates (5 coronary compression, 2 aortic root distortion with cusp flattening, 2 RVOT was too large, and 1 had complex branch stenosis and a short landing zone). Of the 21 patients who were Melody candidates, 12 had conduits, 6 prosthetic valves and 3 native RVOTs. In patients with conduits, the technique of stenting the conduit prior to dilation was used after measuring the distance between the conduit and the coronary arteries on 3DRAA. In the Melody patients, we had 100% procedural success and no serious adverse events (coronary compression, tears, stent fracture or endocarditis). As a tool for case selection, 3DRAA may facilitate higher procedural success and decreased risk of serious adverse events. Furthermore, 3D rotational angiography allows stenting of the conduit prior to dilation, which may prevent tears and possibly endocarditis.
Busch, Raila; Strohbach, Anne; Rethfeldt, Stefanie; Walz, Simon; Busch, Mathias; Petersen, Svea; Felix, Stephan; Sternberg, Katrin
2014-02-01
Despite the development of new coronary stent technologies, in-stent restenosis and stent thrombosis are still clinically relevant. Interactions of blood and tissue cells with the implanted material may represent an important cause of these side effects. We hypothesize material-dependent interaction of blood and tissue cells. The aim of this study is accordingly to investigate the impact of vascular endothelial cells, smooth muscle cells and platelets with various biodegradable polymers to identify a stent coating or platform material that demonstrates excellent endothelial-cell-supportive and non-thrombogenic properties. Human umbilical venous endothelial cells, human coronary arterial endothelial cells and human coronary arterial smooth muscle cells were cultivated on the surfaces of two established biostable polymers used for drug-eluting stents, namely poly(ethylene-co-vinylacetate) (PEVA) and poly(butyl methacrylate) (PBMA). We compared these polymers to new biodegradable polyesters poly(l-lactide) (PLLA), poly(3-hydroxybutyrate) (P(3HB)), poly(4-hydroxybutyrate) (P(4HB)) and a polymeric blend of PLLA/P(4HB) in a ratio of 78/22% (w/w). Biocompatibility tests were performed under static and dynamic conditions. Measurement of cell proliferation, viability, glycocalix width, eNOS and PECAM-1 mRNA expression revealed strong material dependency among the six polymer samples investigated. Only the polymeric blend of PLLA/P(4HB) achieved excellent endothelial markers of biocompatibility. Data show that PLLA and P(4HB) tend to a more thrombotic response, whereas the polymer blend is characterized by a lower thrombotic potential. These data demonstrate material-dependent endothelialization, smooth muscle cell growth and thrombogenicity. Although polymers such as PEVA and PBMA are already commonly used for vascular implants, they did not sufficiently meet the criteria for biocompatibility. The investigated biodegradable polymeric blend PLLA/P(4HB) evidently represents a promising material for vascular stents and stent coatings. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Lemmert, Miguel E; Oldroyd, Keith; Barragan, Paul; Lesiak, Maciej; Byrne, Robert A; Merkulov, Evgeny; Daemen, Joost; Onuma, Yoshinobu; Witberg, Karen; van Geuns, Robert-Jan
2017-05-01
Continuous improvements in stent technology make percutaneous coronary intervention (PCI) a potential alternative to surgery in selected patients with unprotected left main coronary artery (uLMCA) disease. The optimal duration of dual antiplatelet therapy (DAPT) in these patients remains undetermined, and in addition, new stent designs using a bioabsorbable polymer might allow shorter duration of DAPT. IDEAL-LM is a prospective, randomized, multicenter study that will enroll 818 patients undergoing uLMCA PCI. Patients will be randomized in a 1:1 fashion to intravascular ultrasound-guided PCI with the novel everolimus-eluting platinum-chromium Synergy stent with a biodegradable polymer (Boston Scientific, Natick, MA) followed by 4 months of DAPT or the everolimus-eluting cobalt-chromium Xience stent (Abbott Vascular, Santa Clara, CA) followed by 12 months of DAPT. The total follow-up period will be 5 years. A subset of 100 patients will undergo optical coherence tomography at 3 months. The primary end point will be major adverse cardiovascular events (composite of all-cause mortality, myocardial infarction, and ischemia-driven target vessel revascularization) at 2 years. Secondary end points will consist of the individual components of the primary end point, procedural success, a device-oriented composite end point, stent thrombosis as per Academic Research Consortium criteria, and bleeding as per Bleeding Academic Research Consortium criteria. IDEAL-LM is designed to assess the safety and efficacy of the novel Synergy stent followed by 4 months of DAPT vs the Xience stent followed by 12 months of DAPT in patients undergoing uLMCA PCI. The study will provide novel insights regarding optimal treatment strategy for patients undergoing PCI of uLMCA disease (www.clinicaltrials.gov, NCT 02303717). Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
De Rosa, Salvatore; Polimeni, Alberto; Sabatino, Jolanda; Indolfi, Ciro
2017-09-06
Coronary artery bypass graft (CABG) surgery has traditionally represented the standard of care for left main coronary artery (LMCA) disease. However, percutaneous coronary intervention with stent implantation (PCI) has more recently emerged as a valuable alternative. The long-time awaited results of the largest randomized trials on the long-term impact of PCI versus CABG in LMCA disease, the newly published NOBLE and EXCEL studies, revealed contrasting results. Thus, aim of the present meta-analysis was to review the most robust evidence from randomized comparisons of CABG versus PCI for revascularization of LMCA. Randomized studies comparing long-term clinical outcomes of CABG or Stent-PCI for the treatment of LMCA disease were searched for in PubMed, the Chochrane Library and Scopus electronic databases. A total of 5 randomized studies were selected, including 4499 patients. No significant difference between CABG and PCI was found in the primary analysis on the composite endpoint of death, stroke and myocardial infarction (OR = 1·06 95% CI 0·80-1·40; p = 0·70). Similarly, no differences were observed between CABG and PCI for all-cause death (OR = 1·03 95% CI 0·81-1·32; p = 0·81). Although not statistically significant, a lower rate of stroke was registered in the PCI arm (OR = 0·86; p = 0·67), while a lower rate of myocardial infarction was found in the CABG arm (OR = 1·43; p = 0·17). On the contrary, a significantly higher rate of repeat revascularization was registered in the PCI arm (OR = 1·76 95% CI 1·45-2·13; p < 0·001). The present meta-analysis, the most comprehensive and updated to date, including 5 randomized studies and 4499 patients, demonstrates no difference between Stent-PCI and CABG for the treatment of LMCA disease in the composite endpoint of death, stroke and myocardial infarction. Hence, a large part of patients with unprotected left main coronary artery disease can be managed equally well by means of both these revascularization strategies.
The basics of intravascular optical coherence tomography
Jąkała, Jacek; Kałuża, Grzegorz L.; Partyka, Łukasz; Proniewska, Klaudia; Pociask, Elżbieta; Zasada, Wojciech; Wojakowski, Wojciech; Gąsior, Zbigniew; Dudek, Dariusz
2015-01-01
Optical coherence tomography (OCT) has opened new horizons for intravascular coronary imaging. It utilizes near-infrared light to provide a microscopic insight into the pathology of coronary arteries in vivo. Optical coherence tomography is also capable of identifying the chemical composition of atherosclerotic plaques and detecting traits of their vulnerability. At present it is the only tool to measure the thickness of the fibrous cap covering the lipid core of the atheroma, and thus it is an exceptional modality to detect plaques that are prone to rupture (thin fibrous cap atheromas). Moreover, it facilitates distinguishing between plaque rupture and plaque erosion as a cause of acute intracoronary thrombosis. Optical coherence tomography is applied to guide angioplasties of coronary lesions and to assess outcomes of percutaneous coronary interventions broadly. It identifies stent malapposition, dissections, and thrombosis with unprecedented precision. Furthermore, OCT helps to monitor vessel healing after stenting. It evaluates the coverage of stent struts by the neointima and detects in-stent neoatherosclerosis. With so much potential, new studies are warranted to determine OCT's clinical impact. The following review presents the technical background, basics of OCT image interpretation, and practical tips for adequate OCT imaging, and outlines its established and potential clinical application. PMID:26161097
Siminiak, Tomasz; Link, Rafał; Wołoszyn, Maciej; Kałmucki, Piotr; Baszko, Artur
2012-01-01
There is certain experimental and clinical evidence indicating that the covering of bare metal stents (BMS) with drug eluting polymers to produce drug eluting stents (DES) results in increased stent stiffness and modifies the mechanical properties of the stent platform. In addition, it has been speculated that the mechanical performance of DES, compared to BMS, may be related to the type of polymer used to cover stents. We aimed at evaluating the deliverability of DES with a lactate based biodegradable polymer and BMS in patients with stable coronary artery disease in a prospective randomised study. One hundred eleven consecutive patients (age: 36-77, mean 58.8 years) scheduled for routine angioplasty due to stable coronary disease were randomised to receive BMS (Chopin II(TM), Balton, Poland) or paclitaxel eluting stent (Chopin Luc(TM), Balton, Poland) using the same metal platform. Only patients scheduled for angioplasty using the direct implantation technique of a single stent were randomised. The exclusion criteria included patients 〉 80 years, multivessel disease and reference diameter of the target vessel 〉 3.5 mm. In the BMS group (n = 55; 35 males and 20 females), the mean diameter of implanted stents was 3.09 ± 0.40 and the mean length was 11.37 ± 2.80, whereas in the DES group (n = 56; 34 males and 22 females) the mean stent sizes were 3.02 ± 0.34 and 17.90 ± 7.38 mm, respectively (p 〉 0.05 for length). The groups did not significantly differ regarding the frequency of stent implantation to particular coronary vessels. The direct stenting technique was attempted and failed, leading to the stents' implantation after predilatation in five patients in the BMS group and six patients in the DES group. Failure of stent implantation and subsequent implantation of another stent type was observed in no BMS patients and in one DES patient (NS). Although stent covering with lactate based drug eluting polymer may increase its stiffness, it does not affect its deliverability in patients with stable coronary disease.
Ishimaru, Hideki; Nakashima, Kazuaki; Takahata, Hideaki; Matsuoka, Yohjiro
2013-02-01
Although stenting for stenotic vertebral artery dissection (VAD) improves compromised blood flow, subsequent peri-stent aneurysm (PSA) formation is not well-known. We report two cases with PSA successfully treated with coil embolization. Three patients with stenotic intracranial VAD underwent endovascular angioplasty at our institution because they had acute infarction in posterior circulation territory and clinical evidence of hemodynamic insufficiency. In two of three patients balloon angioplasty at first session failed to relieve the stenosis, and a coronary stent was implanted. Angiography immediately after stenting showed no abnormality in case 1 and minimal slit-like projection at proximal portion of the stent in case 2. Angiography obtained 16 months after the stenting revealed PSA in case 1. In case 2, angiography performed 3 months later showed that the projection at proximal portion enlarged and formed an aneurysm outside the stent. Because follow-up angiographies showed growth of the aneurysm in both cases, endovascular aneurysmal embolization was performed. We advanced a microcatheter into the aneurysm through the strut of existing stent and delivered detachable coils into the aneurysm lumen successfully in both cases. The post-procedural course was uneventful, and complete obliteration of aneurysm was confirmed on angiography in both cases. Stenting for stenotic intracranial VAD may result in delayed PSA; therefore, follow-up angiographies would be necessary after stenting for stenotic intracranial arterial dissection. Coil embolization through the stent strut would be a solution for enlarging PSA.
Jain, Deepak; Kurowski, Volkhard; Katus, Hugo A; Richardt, Gert
2002-10-01
An elderly gentleman had a dissection of the left main coronary artery (LMCA) during coronary angiography. There were critical lesions in the left anterior descending (LAD) and left circumflex arteries. Both the LMCA and the LAD lesions were successfully stented in the same sitting. Thereafter the patient remained symptom free and the six-month follow-up angiogram revealed good angioplasty results in both lesions. We report this case for two reasons - first, acute dissection of the LMCA is a rare but devastating complication of selective coronary angiography and the situation becomes graver if the branch vessels have critical stenosis; that this could be managed percutaneously needs to be highlighted, and second, the case offers an opportunity to review literature pertinent to this awesome occurrence in the catheterization laboratory.
Cohen, David J; Osnabrugge, Ruben L; Magnuson, Elizabeth A; Wang, Kaijun; Li, Haiyan; Chinnakondepalli, Khaja; Pinto, Duane; Abdallah, Mouin S; Vilain, Katherine A; Morice, Marie-Claude; Dawkins, Keith D; Kappetein, A Pieter; Mohr, Friedrich W; Serruys, Patrick W
2014-09-30
The Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery (SYNTAX) trial demonstrated that in patients with 3-vessel or left main coronary artery disease, coronary artery bypass graft surgery (CABG) was associated with a lower rate of cardiovascular death, myocardial infarction, stroke, or repeat revascularization compared with percutaneous coronary revascularization with drug-eluting stents (DES-PCI)). The long-term cost-effectiveness of these strategies is unknown. Between 2005 and 2007, 1800 patients with left main or 3-vessel coronary artery disease were randomized to CABG (n=897) or DES-PCI (n=903). Costs were assessed from a US perspective, and health state utilities were evaluated with the EuroQOL questionnaire. A patient-level microsimulation model based on the 5-year in-trial data was used to extrapolate costs, life expectancy, and quality-adjusted life expectancy over a lifetime horizon. Although initial procedural costs were $3415 per patient lower with CABG, total hospitalization costs were $10 036 per patient higher. Over the next 5 years, follow-up costs were higher with DES-PCI as a result of more frequent hospitalizations, revascularization procedures, and higher medication costs. Over a lifetime horizon, CABG remained more costly than DES-PCI, but the incremental cost-effectiveness ratio was favorable ($16 537 per quality-adjusted life-year gained) and remained <$20 000 per quality-adjusted life-year in most bootstrap replicates. Results were consistent across a wide range of assumptions about the long-term effect of CABG versus DES-PCI on events and costs. In patients with left main disease or a SYNTAX score ≤22, however, DES-PCI was economically dominant compared with CABG, although these findings were less certain. For most patients with 3-vessel or left main coronary artery disease, CABG is a clinically and economically attractive revascularization strategy compared with DES-PCI. However, among patients with less complex disease, DES-PCI may be preferred on both clinical and economic grounds. www.clinicaltrials.gov. Unique identifier: NCT00114972. © 2014 American Heart Association, Inc.
Kini, Annapoorna S; Vengrenyuk, Yuliya; Pena, Jacobo; Motoyama, Sadako; Feig, Jonathan E; Meelu, Omar A; Rajamanickam, Anitha; Bhat, Arjun M; Panwar, Sadik; Baber, Usman; Sharma, Samin K
2015-11-15
This study sought to assess the mechanistic effect of rotational atherectomy (RA) and orbital atherectomy (OA) on heavily calcified coronary lesions and subsequent stent placement using optical coherence tomography (OCT). RA and OA are two main approaches to ablate coronary calcium. While small case reports have described the mechanistic effect of RA in calcified coronary lesions, there has been no imaging study to assess the effect of OA on coronary artery architecture and/or compare the effects of two atherectomy devices. This study analyzed 20 consecutive patients with OCT imaging performed after atherectomy and after stent implantation, RA (n = 10) and OA (n = 10). Postatherectomy OCT analysis identified tissue modification with deep dissections in around a third of lesions after RA and OA; however, post OA dissections ("lacunae") were significantly deeper (1.14 vs. 0.82 mm, P = 0.048). Post OA/RA lesions with dissections had significantly higher percentage of lipid rich plaques and smaller calcification arcs as compared to plaques without dissections. Stents after OA were associated with a significantly lower percent of stent strut malapposition than post RA stents (4.36 vs. 8.02%, P = 0.038). Although the incidence of dissections was comparable between RA and OA cases, OA resulted in deeper tissue modifications (lacunae) as shown by OCT imaging. The finding might provide an explanation for a better stent apposition after OA as compared to RA. Their impact on long-term outcome needs to be determined. © 2015 Wiley Periodicals, Inc.
Intravascular Ultrasound to Guide Percutaneous Coronary Interventions
2006-01-01
Executive Summary Objective The objective of this health technology policy assessment was to determine the effectiveness and cost-effectiveness of using intravascular ultrasound (IVUS) as an adjunctive imaging tool to coronary angiography for guiding percutaneous coronary interventions. Background Intravascular Ultrasound Intravascular ultrasound is a procedure that uses high frequency sound waves to acquire 3-dimensional images from the lumen of a blood vessel. The equipment for performing IVUS consists of a percutaneous transducer catheter and a console for reconstructing images. IVUS has been used to study the structure of the arterial wall and nature of atherosclerotic plaques, and obtain measurements of the vessel lumen. Its role in guiding stent placement is also being investigated. IVUS is presently not an insured health service in Ontario. Clinical Need Coronary artery disease accounts for approximately 55% of cardiovascular deaths, the leading cause of death in Canada. In Ontario, the annual mortality rate due to ischemic heart disease was 141.8 per 100,000 population between 1995 and 1997. Percutaneous coronary intervention (PCI), a less invasive approach to treating coronary artery disease, is used more frequently than coronary bypass surgery in Ontario. The number of percutaneous coronary intervention procedures funded by the Ontario Ministry of Health and Long-term Care is expected to increase from approximately 17, 780 in 2004/2005 to 22,355 in 2006/2007 (an increase of 26%), with about 95% requiring the placement of one or more stents. Restenosis following percutaneous coronary interventions involving bare metal stents occurs in 15% to 30% of the cases, mainly because of smooth muscle proliferation and migration, and production of extracellular matrix. In-stent restenosis has been linked to suboptimal stent expansion and inadequate lesion coverage, while stent thrombosis has been attributed to incomplete stent-to-vessel wall apposition. Since coronary angiography (the imaging tool used to guide stent placement) has been shown to be inaccurate in assessing optimal stent placement, and IVUS can provide better views of the vessel lumen, the clinical utility of IVUS as an imaging tool adjunctive to coronary angiography in coronary intervention procedures has been explored in clinical studies. Method A systematic review was conducted to answer the following questions: What are the procedure-related complications associated with IVUS? Does IVUS used in conjunction with angiography to guide percutaneous interventions improve patient outcomes compared to angiographic guidance without IVUS? Who would benefit most in terms of clinical outcomes from the use of IVUS adjunctive to coronary angiography in guiding PCIs? What is the effectiveness of IVUS guidance in the context of drug-eluting stents? What is the cost-effectiveness ratio and budget impact of adjunctive IVUS in PCIs in Ontario? A systematic search of databases OVID MEDLINE, EMBASE, MEDLINE In-Process & Other Non-Indexed Citations, The Cochrane Library, and the International Agency for Health Technology Assessment (INAHTA) database for the period beginning in May 2001 until the day of the search, November 4, 2005 yielded 2 systematic reviews, 1 meta-analysis, 6 randomized controlled trials, and 2 non-randomized studies on left main coronary arteries. The quality of the studies ranged from moderate to high. These reports were combined with reports from a previous systematic review for analysis. In addition to qualitative synthesis, pooled analyses of data from randomized controlled studies using a random effect model in the Cochrane Review Manager 4.2 software were conducted when possible. Findings of Literature Review & Analysis Safety Intravascular ultrasound appears to be a safe tool when used in coronary interventions. Periprocedural complications associated with the use of IVUS in coronary interventions ranged from 0.5% in the largest study to 4%. Coronary rupture was reported in 1 study (1/54). Other complications included prolonged spasms of the artery after stenting, dissection, and femoral aneurysm. Effectiveness Based on pooled analyses of data from randomized controlled studies, the use of intravascular ultrasound adjunctive to coronary intervention in percutaneous coronary interventions using bare metal stents yielded the following findings: For lesions predominantly at low risk of restenosis: There were no significant differences in preintervention angiographic minimal lumen diameter between the IVUS-guided and angiography-guided groups. IVUS guidance resulted in a significantly larger mean postintervention angiographic minimal lumen diameter (weighted mean difference of 0.11 mm, P = .0003) compared to angiographic guidance alone. The benefit in angiographic minimal lumen diameter from IVUS guidance was not maintained at 6-month follow-up, when no significant difference in angiographic minimal lumen diameter could be detected between the two arms (weighted mean difference 0.08, P = .13). There were no statistically significant differences in angiographic binary restenosis rates between IVUS-guidance and no IVUS guidance (Odds ratio [OR] 0.87 in favour of IVUS, 95% Confidence Interval [CI] [0.64–1.18], P = 0.37). IVUS guidance resulted in a reduction in the odds of target lesion revascularization (repeat percutaneous coronary intervention or coronary bypass graft) compared to angiographic guidance alone. The reduction was statistically significant at a follow-up period of 6 months to 1 year, and at a follow-up period of 18 month to 2 years (OR 0.52 in favour of IVUS, 95% CI [0.33–0.81], P = .004). Total revascularization rate (either target lesion or target vessel revascularization) was significantly lower for IVUS-guided patients at 18 months to 2.5 years after intervention (OR 0.43 in favour of IVUS, 95% CI [0.29–0.63], p < .0001). There were no statistically significant differences in the odds of death (OR 1.36 in favour of no IVUS, P =0.65) or myocardial infarction (OR 0.95 in favour of IVUS, P = 0.93) between IVUS-guidance and angiographic guidance alone at up to 2.5 years of follow-up The odds of having a major cardiac event (defined as death, myocardial infarction, and target lesion or target vessel revascularization) were significantly lower for patients with IVUS guidance compared to angiographic guidance alone during follow-up periods of up to 2.5 years (OR 0.53, 95% CI [0.36–0.78], P = 0.001). Since there were no significant reductions in the odds of death or myocardial infarction, the reduction in the odds of combined events reflected mainly the reduction in revascularization rates. For lesions at High Risk of Restenosis: There is evidence from one small, randomized controlled trial (n=150) that IVUS-guided percutaneous coronary intervention in long de novo lesions (>20 mm) of native coronary arteries resulted in statistically significant larger minimal lumen Diameter, and statistically significant lower 6-month angiographic binary restenosis rate. Target vessel revascularization rate and the rate of combined events were also significantly reduced at 12 months. A small subgroup analysis of a randomized controlled trial reported no benefit in clinical or angiographic outcomes for IVUS-guided percutaneous coronary interventions in patients with diabetes compared to those guided by angiography. However, due to the nature and size of the analysis, no firm conclusions could be reached. Based on 2 small, prospective, non-randomized controlled studies, IVUS guidance in percutaneous coronary interventions of left main coronary lesions using bare metal stents or drug-eluting stents did not result in any benefits in angiographic or clinical outcomes. These findings need to be confirmed. Interventions Using Drug-Eluting Stents There is presently no evidence on whether the addition of IVUS guidance during the implantation of drug-eluting stents would reduce incomplete stent apposition, or improve the angiographic or clinical outcomes of patients. Ontario-Based Economic Analysis Cost-effectiveness analysis showed that PCIs using IVUS guidance would likely be less costly and more effective than PCIs without IVUS guidance. The upfront cost of adjunctive use of IVUS in PCIs ranged from $1.56 million at 6% uptake to $13.04 million at 50% uptake. Taking into consideration cost avoidance from reduction in revascularization associated with the use of IVUS, a net saving of $0.63 million to $5.2 million is expected. However, since it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS can be generalized to clinical settings in Ontario, further analysis on the budget impact and cost-effectiveness need to be conducted once Ontario-specific revascularization rates are verified. Factors to be Considered in the Ontario Context Applicability of Findings to Ontario The interim analysis of an Ontario field evaluation that compared drug-eluting stents to bare metal stents showed that the revascularization rates in low-risk patients with bare metal stents were much lower in Ontario compared to rates reported in randomized controlled trials (7.2% vs >17 %). Even though IVUS is presently not routinely used in the stenting of low-risk patients in Ontario, the revascularization rates in these patients in Ontario were shown to be lower than those reported for the IVUS groups reported in published studies. Based on this information and previous findings from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rates from IVUS guidance can be generalized to Ontario. In light of the above findings, it is advisable to validate the reported benefits of IVUS guidance in percutaneous coronary interventions involving bare metal stents in the Ontario context. Licensing Status As of January 16, 2006, Health Canada has licensed 10 intravascular ultrasound imaging systems/catheters for transluminal intervention procedures, most as class 4 medical devices. Current Funding IVUS is presently not an insured procedure under the Ontario Health Insurance Plan and there are no professional fees for this procedure. All costs related to the use of IVUS are covered within hospitals’ global budgets. A single use IVUS catheter costs approximately $900CDN and the procedure adds approximately 20 minutes to 30 minutes to a percutaneous coronary intervention procedure. Diffusion According to an expert consultant, current use of IVUS in coronary interventions in Ontario is probably limited to high-risk cases such as interventions in long lesions, small vessels, and bifurcated lesions for which images from coronary angiography are indeterminate. It was estimated that IVUS is being used in about 6% of all percutaneous coronary interventions at a large Ontario cardiac centre. Expert Opinion IVUS greatly enhances the cardiac interventionists’ ability to visualize and assess high-risk lesions such as long lesions, narrow lesions, and bifurcated lesions that may have indeterminate angiographic images. Information from IVUS in these cases facilitates the choice of the most appropriate approach for the intervention. Conclusion The use of adjunctive IVUS in PCIs using bare metal stents in lesions predominantly at low risk for restenosis had no significant impact on survival, myocardial infarction, or angiographic restenosis rates up to 2.5 years after intervention. The use of IVUS adjunctive to coronary angiography in percutaneous coronary interventions using bare metal stents in lesions predominantly at low risk for restenosis significantly reduced the target lesion and target vessel revascularization at a follow-up period of 18 months to 2.5 years. One small study suggests that adjunctive IVUS in PCIs using bare metal stents in long lesions (>20 mm) significantly improved the 6-month angiographic restenosis rate and one-year target lesion revascularization rate. These results need to be confirmed with large randomized controlled trials. Based on information from the Ontario field evaluation on stenting, it is uncertain whether the reduction in revascularization rate resulting from the use of IVUS in the placement of bare metal stents can be generalized to clinical settings in Ontario. There is presently insufficient evidence available to determine the impact of adjunctive IVUS in percutaneous interventions in high-risk lesions (other than long lesions) or in PCIs using drug-eluting stents. PMID:23074482
Results of completion arteriography after minimally invasive off-pump coronary artery bypass.
Hoff, Steven J; Ball, Stephen K; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Petracek, Michael R; Ahmad, Rashid; Greelish, James P; Walker, Kristie; Byrne, John G
2011-01-01
The benefits of a minimally invasive approach to off-pump coronary artery bypass remain controversial. The value of completion arteriography in validating this technique has not been investigated. From April 2007 to October 2009, fifty-six patients underwent isolated minimally invasive coronary artery bypass grafting through a left thoracotomy without cardiopulmonary bypass. Forty-three of these patients underwent completion arteriography. Sixty-five grafts were performed in these 56 patients, (average, 1.2 grafts per patient; range, 1 to 3). Forty-eight grafts were studied in the 43 patients undergoing completion arteriography. There were 4 findings on arteriogram leading to further immediate intervention (8.3%). These included 3 grafts with anastomotic stenoses or spasm requiring stent placement, and 1 patient who had limited dissection in the left internal mammary artery graft and underwent placement of an additional vein graft. These findings were independent of electrocardiographic changes or hemodynamic instability. The remainder of the studies showed no significant abnormalities. There were no deaths. One patient who did not have a completion arteriogram suffered a postoperative myocardial infarction requiring stent placement for anastomotic stenosis. Patients were discharged home an average of 6.8 days postoperatively. There were no instances of renal dysfunction postoperatively attributable to catheterization. Minimally invasive coronary artery bypass is safe and effective. Findings of completion arteriography occasionally reveal previously under-recognized findings that, if corrected in a timely fashion, could potentially impact graft patency and clinical outcomes. Our experience validates this minimally invasive technique. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
van Brussel, Peter M; van de Hoef, Tim P; de Winter, Robbert J; Vogt, Liffert; van den Born, Bert-Jan
2017-05-22
Interventions targeting renal artery stenoses have been shown to lower blood pressure and preserve renal function. In recent studies, the efficacy of catheter-based percutaneous transluminal renal angioplasty with stent placement has been called into question. In the identification of functional coronary lesions, hyperemic measurements have earned a place in daily practice for clinical decision making, allowing discrimination between solitary coronary lesions and diffuse microvascular disease. Next to differences in clinical characteristics, the selection of renal arteries suitable for intervention is currently on the basis of anatomic grading of the stenosis by angiography rather than functional assessment under hyperemia. It is conceivable that, like the coronary circulation, functional measurements may better predict therapeutic efficacy of percutaneous transluminal renal angioplasty with stent placement. In this systematic review, the authors evaluate the available clinical evidence on the optimal hyperemic agents to induce intrarenal hyperemia, their association with anatomic grading, and their predictive value for treatment effects. In addition, the potential value of combined pressure and flow measurements to discriminate macrovascular from microvascular disease is discussed. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Puymirat, Etienne; Blanchard, Didier; Perier, Marie-Cécile; PiaDonataccio, Maria; Gilard, Martine; Lefèvre, Thierry; Mulak, Geneviève; le Breton, Hervé; Danchin, Nicolas; Spaulding, Christian; Jouven, Xavier
2013-08-01
The national observational study of diagnostic and interventional cardiac catheterization (ONACI) is a prospective multicenter registry of the French Society of Cardiology including all interventional cardiology procedures performed from 2004. We aimed to evaluate "real-world" management of patients with coronary artery disease in France from this registry. The present study was focused on data collected from 2004 to 2008. Patient demographics and co-morbidities, invasive parameters, treatment options, and procedural techniques were prospectively collected. Patients were recruited from 99 hospitals (55% of patients were hospitalized in private clinics and 45% in public institutions). During a 5-year period, a total of 298,105 patients underwent coronary angiography and 176,166 patients underwent percutaneous coronary intervention. Diagnosis was acute coronary syndrome in 22%, stable angina or silent ischemia in 23%, and atypical chest pain in 9% of cases. Normal coronary arteries or nonsignificant coronary narrowing were found in 26% of patients. Radial access was increasingly used over the years regardless of the indication. The average number of percutaneous coronary interventions per procedure was 1.5 ± 0.7 (range, 1.3 ± 0.7 to 1.5 ± 0.7) and that of stents per procedure was 1.5 ± 0.8 (range, 1.5 ± 0.8 to 1.6 ± 0.8). Drug-eluting stents were used in 45% (range, 34% to 62%), increasing from 2004 to 2006, and then decreasing after the 2006 controversy. In conclusion, ONACI is one of the largest catheterization registries during this period, providing a detailed and comprehensive global description of the spectrum and management of patients with suspected coronary artery disease undergoing cardiac catheterization. Copyright © 2013 Elsevier Inc. All rights reserved.
Nanotechnology in diagnosis and treatment of coronary artery disease.
Karimi, Mahdi; Zare, Hossein; Bakhshian Nik, Amirala; Yazdani, Narges; Hamrang, Mohammad; Mohamed, Elmira; Sahandi Zangabad, Parham; Moosavi Basri, Seyed Masoud; Bakhtiari, Leila; Hamblin, Michael R
2016-01-01
Nanotechnology could provide a new complementary approach to treat coronary artery disease (CAD) which is now one of the biggest killers in the Western world. The course of events, which leads to atherosclerosis and CAD, involves many biological factors and cellular disease processes which may be mitigated by therapeutic methods enhanced by nanotechnology. Nanoparticles can provide a variety of delivery systems for cargoes such as drugs and genes that can address many problems within the arteries. In order to improve the performance of current stents, nanotechnology provides different nanomaterial coatings, in addition to controlled-release nanocarriers, to prevent in-stent restenosis. Nanotechnology can increase the efficiency of drugs, improve local and systematic delivery to atherosclerotic plaques and reduce the inflammatory or angiogenic response after intravascular intervention. Nanocarriers have potential for delivery of imaging and diagnostic agents to precisely targeted destinations. This review paper will cover the current applications and future outlook of nanotechnology, as well as the main diagnostic methods, in the treatment of CAD.
Nanotechnology in diagnosis and treatment of coronary artery disease
Karimi, Mahdi; Zare, Hossein; Bakhshian Nik, Amirala; Yazdani, Narges; Hamrang, Mohammad; Mohamed, Elmira; Sahandi Zangabad, Parham; Moosavi Basri, Seyed Masoud; Bakhtiari, Leila; Hamblin, Michael R
2016-01-01
Nanotechnology could provide a new complementary approach to treat coronary artery disease (CAD) which is now one of the biggest killers in the Western world. The course of events, which leads to atherosclerosis and CAD, involves many biological factors and cellular disease processes which may be mitigated by therapeutic methods enhanced by nanotechnology. Nanoparticles can provide a variety of delivery systems for cargoes such as drugs and genes that can address many problems within the arteries. In order to improve the performance of current stents, nanotechnology provides different nanomaterial coatings, in addition to controlled-release nanocarriers, to prevent in-stent restenosis. Nanotechnology can increase the efficiency of drugs, improve local and systematic delivery to atherosclerotic plaques and reduce the inflammatory or angiogenic response after intravascular intervention. Nanocarriers have potential for delivery of imaging and diagnostic agents to precisely targeted destinations. This review paper will cover the current applications and future outlook of nanotechnology, as well as the main diagnostic methods, in the treatment of CAD. PMID:26906471
Brountzos, E N; Petersen, B; Binkert, C; Panagiotou, I; Kaufman, J A
2004-01-01
To review immediate and midterm results of primary stenting for innominate and subclavian artery occlusive lesions. Retrospective data were collected from 48 consecutive symptomatic patients (27 men and 21 women, median age 64 years) having 49 subclavian and innominate artery lesions treated with stenting. Of the patients 52% had concomitant ischemic heart disease, and 30% had carotid and/or vertebral artery disease. Indication for treatment was vertebrobasilar insufficiency (VBI) in 16.6% of the patients; upper limb ischemia (ULI) in 31.3%; VBI and ULI in 12.5%; transient ischemic attack in 16.7%; angina in 12.5% before or after left internal mammary artery-to-coronary artery bypass grafting; and leg claudication in 10.4% before or after axillofemoral bypass grafting. Balloon-expandable stents were used in 44 lesions and self-expandable stents in 5 lesions. In total, 53 stents were placed in 48 patients. Technical success was 96%, and clinical success 94%. We encountered four complications (two puncture site hematomas, one distal hand embolization and one transient cerebral ischemia). Two patients died within 30 days from other causes, and seven patients were lost to follow-up. Mean follow-up time was 16.7 months (range 0.3 to 68.2). Five patients had recurrent lesions treated by surgical (n = 2) or endovascular (n = 3) means. Cumulative primary patency rate was 91.7% and 77% at 12 and 24 months, respectively. Cumulative secondary patency rate was 96.5% and 91.7% at 12 and 24 months, respectively. Stenting of subclavian and innominate artery lesions resulted in immediate resolution of patients' symptoms with durable midterm effect and few complications in a larger patient group with serious comorbid conditions.
Endovascular Repair of a Ruptured Mycotic Aneurysm of the Common Iliac Artery
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mofidi, R., E-mail: rmofidi@doctors.net.uk; Bhat, R.; Nagy, J.
2007-09-15
This report describes the case of a ruptured mycotic aneurysm of the left common iliac artery, successfully treated with endovascular stent-grafting. A 64-year-old woman underwent diagnostic coronary angiography complicated by an infected hematoma of the left groin. Seven days later, she developed methicillin-resistant Staphylococcus aureus septicemia and CT scan evidence of perivascular inflammation around the left common iliac artery. This was followed by rupture of a mycotic aneurysm of the left common iliac artery. The lesion was successfully treated with a stent-graft and prolonged antibiotic therapy, and the patient remains free of infection 10 months later. Accumulating evidence suggests thatmore » endovascular repair can be used safely for the repair of ruptured infected aneurysms.« less
High-definition computed tomography for coronary artery stent imaging: a phantom study.
Yang, Wen Jie; Chen, Ke Min; Pang, Li Fang; Guo, Ying; Li, Jian Ying; Zhang, Huang; Pan, Zi Lai
2012-01-01
To assess the performance of a high-definition CT (HDCT) for imaging small caliber coronary stents (≤ 3 mm) by comparing different scan modes of a conventional 64-row standard-definition CT (SDCT). A cardiac phantom with twelve stents (2.5 mm and 3.0 mm in diameter) was scanned by HDCT and SDCT. The scan modes were retrospective electrocardiography (ECG)-gated helical and prospective ECG-triggered axial with tube voltages of 120 kVp and 100 kVp, respectively. The inner stent diameters (ISD) and the in-stent attenuation value (AV(in-stent)) and the in-vessel extra-stent attenuation value (AV(in-vessel)) were measured by two observers. The artificial lumen narrowing (ALN = [ISD - ISD(measured)]/ISD) and artificial attenuation increase between in-stent and in-vessel (AAI = AV(in-stent) - AV(in-vessel)) were calculated. All data was analyzed by intraclass correlation and ANOVA-test. The correlation coefficient of ISD, AV(in-vessel) and AV(in-stent) between the two observers was good. The ALNs of HDCT were statistically lower than that of SDCT (30 ± 5.7% versus 35 ± 5.4%, p < 0.05). HDCT had statistically lower AAI values than SDCT (15.7 ± 81.4 HU versus 71.4 ± 90.5 HU, p < 0.05). The prospective axial dataset demonstrated smaller ALN than the retrospective helical dataset on both HDCT and SDCT (p < 0.05). Additionally, there were no differences in ALN between the 120 kVp and 100 kVp tube voltages on HDCT (p = 0.05). High-definition CT helps improve measurement accuracy for imaging coronary stents compared to SDCT. HDCT with 100 kVp and the prospective ECG-triggered axial technique, with a lower radiation dose than 120 kVp application, may be advantageous in evaluating coronary stents with smaller calibers (≤ 3 mm).
Kawamoto, Hiroyoshi; Chieffo, Alaide; D'Ascenzo, Fabrizio; Jabbour, Richard J; Naganuma, Toru; Cerrato, Enrico; Ugo, Fabrizio; Pavani, Marco; Varbella, Ferdinando; Boccuzzi, Giacomo; Pennone, Mauro; Garbo, Roberto; Conrotto, Federico; Biondi-Zoccai, Giuseppe; D'Amico, Maurizio; Moretti, Claudio; Escaned, Javier; Gaita, Fiorenzo; Nakamura, Sunao; Colombo, Antonio
2018-01-01
This study sought to investigate the optimal percutaneous coronary intervention (PCI) strategy for true unprotected left main coronary artery (ULMCA) bifurcations. The FAILS-2 was a retrospective multi-center study including patients with ULMCA disease treated with second-generation drug-eluting stents. Of these, we compared clinical outcomes of a provisional strategy (PS; n=216) versus an elective two-stent strategy (E2S; n=161) for true ULMCA bifurcations. The primary endpoint was the incidence of major adverse cardiac events (MACEs) at 3-years. We further performed propensity-score adjustment for clinical outcomes. There were no significant differences between the groups in terms of patient and lesion characteristics. 9.7% of patients in the PS group crossed over to a provisional two-stent strategy. MACEs were not significantly different between groups (MACE at 3-year; PS 28.1% vs. E2S 28.9%, adjusted p=0.99). The rates of target lesion revascularization (TLR) on the circumflex artery (LCX) were numerically high in the E2S group (LCX-TLR at 3-years; PS 11.8% vs. E2S 16.6%, adjusted p=0.51). E2S was associated with a comparable MACE rate to PS for true ULMCA bifurcations. The rates of LCX-TLR tended to be higher in the E2S group although there was no statistical significance. This study sought to compare the clinical outcomes of a provisional strategy (PS) with an elective two-stent strategy (E2S) for the treatment of true unprotected left main coronary artery bifurcations. 377 Patients (PS 216 vs. E2S 161 patients) were evaluated, and 9.7% in the PS group crossed over to a two-stent strategy. E2S was associated with a similar major adverse cardiac event rate at 3-years when compared to the PS strategy (PS 28.1% vs. E2S 28.9%, p=0.99). However, the left circumflex artery TLR rate at 3-year tended to be higher in the E2S group (PS 11.8% vs. E2S 16.6%, p=0.51). Copyright © 2017 Elsevier B.V. All rights reserved.
Lee, Michael; Généreux, Philippe; Shlofmitz, Richard; Phillipson, Daniel; Anose, Bynthia M; Martinsen, Brad J; Himmelstein, Stevan I; Chambers, Jeff W
2017-06-01
The presence of heavy coronary artery calcification increases the complexity of percutaneous coronary intervention (PCI) and increases the incidence of major adverse cardiac events (MACE): death, myocardial infarction (MI), target vessel revascularization (TVR), and stent thrombosis. The ORBIT II (Evaluate the Safety and Efficacy of OAS in Treating Severely Calcified Coronary Lesions) trial reported low rates of procedural, 30-day, 1-year, and 2-year ischemic complications after treatment of de novo, severely calcified lesions with the Diamondback 360° Coronary Orbital Atherectomy System (OAS) (Cardiovascular Systems, Inc.). ORBIT II was a single-arm trial that enrolled 443 patients at 49U.S. sites; in this study, de novo, severely calcified coronary lesions were treated with OAS prior to stenting. The primary safety endpoint was 30-day MACE: the composite of cardiac death, MI, and TVR (inclusive of target lesion revascularization (TLR)). The primary efficacy endpoint was procedural success: stent delivery with a residual stenosis of <50% without the occurrence of in-hospital MACE.The present analysis reports the final, 3-year follow-up results from ORBIT II. The majority of subjects (88.2%) underwent PCI with drug-eluting stents after orbital atherectomy. There were 360 (81.3%) subjects who completed the protocol-mandated 3-year visit.The overall cumulative rate of 3-year MACE was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%). The 3-year target lesion revascularization rate was 7.8%. In the final 3-year analysis of the ORBIT II trial, orbital atherectomy of severely calcified coronary lesions followed by stenting resulted in a low rate of adverse ischemic events compared with historical controls.Orbital atherectomy represents a safe and effective revascularization strategy for patients with severely calcified coronary lesions. The ORBIT II trial enrolled 443 subjects to study orbital atherectomy followed by stenting for de novo severely calcified coronary lesions. The overall cumulative 3-year MACE rate was 23.5%, including cardiac death (6.7%), MI (11.2%), and TVR (10.2%); the 3-year target lesion revascularization rate was 7.8%. Orbital atherectomy of heavily calcified coronary lesions followed by stenting results in a low rate of adverse ischemic events compared with historical controls; it represents a reasonable revascularization strategy for patients with severely calcified coronary lesions. Copyright © 2017 Elsevier Inc. All rights reserved.
Grines, Cindy L; Bonow, Robert O; Casey, Donald E; Gardner, Timothy J; Lockhart, Peter B; Moliterno, David J; O'Gara, Patrick; Whitlow, Patrick
2007-02-15
Dual antiplatelet therapy with aspirin and a thienopyridine has been shown to reduce cardiac events after coronary stenting. However, many patients and healthcare providers prematurely discontinue dual antiplatelet therapy, which greatly increases the risk of stent thrombosis, myocardial infarction, and death. This advisory stresses the importance of 12 months of dual antiplatelet therapy after placement of a drug-eluting stent and educating the patient and healthcare providers about hazards of premature discontinuation. It also recommends postponing elective surgery for 1 year, and if surgery cannot be deferred, considering the continuation of aspirin during the perioperative period in high-risk patients with drug-eluting stents. (c) 2007 the American Heart Association, Inc., the American College of Cardiology Foundation, the Society for Cardiovascular Angiography and Interventions, the American College of Surgeons, and the American Dental Association
Tung, Ying-Chang; Hsiao, Ping-Gune; Hsu, Lung-An; Kuo, Chi-Tai; Chang, Chi-Jen
2014-05-01
The expanded usage of drug-eluting stents (DES) in treating patients with multivessel coronary artery disease (CAD) may sometimes be limited in real-world practice due to cost concerns. We compared the clinical outcomes of exclusive and selective DES use in treating patients with multivessel CAD. From November 2004 to December 2011, 110 patients with multivessel CAD who received four or more stents were enrolled into this study, and divided into two groups according to the DES strategy employed: exclusive DES (n = 52), or selective DES (n = 58). In the selective DES group, DES was reserved for complex lesions only, such that the incidence and predictors of clinical events were assessed. At a mean follow-up of 41.4 ± 26.5 months, there were no significant differences between the two strategies in terms of baseline characteristics, all-cause mortality (exclusive vs. selective: 1.9% vs. 6.9%, p = 0.21), cardiac death (1.9% vs. 1.7%, p = 0.94) and nonfatal myocardial infarction (3.8% vs. 5.2%, p = 0.74). Despite the presence of more ostial lesions in the exclusive DES group, there was a trend such that major adverse cardiac events (MACE) and target lesion revascularization (TLR) rates were higher in the selective DES group (MACE: 17.3% vs. 31%, p = 0.16; TLR: 11.5% vs. 24.1%, p = 0.08). The higher MACE rate in the selective DES group was mainly driven by a higher target vessel revascularization (TVR) rate (15.4% vs. 29.3%, p = 0.08). In the exclusive DES group, SYNTAX score was an independent predictor of MACE [Haxard ratio (HR): 1.09, 95% confidence internal (CI): 1.02-1.16, p = 0.01] and TVR (HR 1.08, 95% CI 1.01-1.15, p = 0.04). Compared to the exclusive DES strategy, the selective DES strategy with reservation of DES for complex lesions is associated with numerically higher, but not statistically significant, rates of MACE and all-cause mortality in this small group of patients with multivessel CAD receiving four or more stents. Bare metal stent; Drug-eluting stent; Multivessel coronary artery disease.
Parpugga, Tajinder Kumar; Tatarunas, Vacis; Skipskis, Vilius; Kupstyte, Nora; Zaliaduonyte-Peksiene, Diana; Lesauskaite, Vaiva
2015-01-01
Data on the impact of PAI-1-675 4G/5G genotype for fibrinolysis during myocardial infarction are inconsistent. The aim of our study was to evaluate the association of clinical and genetic (PAI-1-675 4G/5G polymorphism) factors with coronary artery occlusion in patients with myocardial infarction. PAI-1-675 4G/5G detection was achieved by using Sanger sequencing in a sample of patients hospitalized for stent implantation due to myocardial infarction. We categorized the patients into two groups: patients with coronary artery occlusion and patients without coronary artery occlusion according to angiographic evaluation. We identified n = 122 (32.4%) 4G/4G, n = 186 (49.5%) 4G/5G, and n = 68 (18.1%) 5G/5G PAI-1 genotype carriers. Univariate and multivariate analysis showed that only the 4G/5G genotype was associated with coronary artery occlusion (OR: 1.656 and 95% CI: 1.009-2.718, p = 0.046). Our results showed that carriers of PAI-1 4G/5G genotype with myocardial infarction have increased odds of coronary artery occlusion more than 1.6 times in comparison to the carriers of homozygous genotypes.
Parpugga, Tajinder Kumar; Tatarunas, Vacis; Skipskis, Vilius; Kupstyte, Nora; Zaliaduonyte-Peksiene, Diana; Lesauskaite, Vaiva
2015-01-01
Objective. Data on the impact of PAI-1-675 4G/5G genotype for fibrinolysis during myocardial infarction are inconsistent. The aim of our study was to evaluate the association of clinical and genetic (PAI-1-675 4G/5G polymorphism) factors with coronary artery occlusion in patients with myocardial infarction. Materials and Methods. PAI-1-675 4G/5G detection was achieved by using Sanger sequencing in a sample of patients hospitalized for stent implantation due to myocardial infarction. We categorized the patients into two groups: patients with coronary artery occlusion and patients without coronary artery occlusion according to angiographic evaluation. Results. We identified n = 122 (32.4%) 4G/4G, n = 186 (49.5%) 4G/5G, and n = 68 (18.1%) 5G/5G PAI-1 genotype carriers. Univariate and multivariate analysis showed that only the 4G/5G genotype was associated with coronary artery occlusion (OR: 1.656 and 95% CI: 1.009–2.718, p = 0.046). Conclusions. Our results showed that carriers of PAI-1 4G/5G genotype with myocardial infarction have increased odds of coronary artery occlusion more than 1.6 times in comparison to the carriers of homozygous genotypes. PMID:26273123
Outcomes in Diabetic Patients Undergoing Orbital Atherectomy System.
Lee, Michael S; Shlofmitz, Evan; Nguyen, Heajung; Shlofmitz, Richard A
2016-10-01
We evaluated the angiographic and clinical outcomes of orbital atherectomy to treat severely calcified coronary lesions in diabetic and non-diabetic patients. Diabetics have increased risk for death, myocardial infarction, and target vessel revascularization after percutaneous coronary intervention. Severely calcified coronary lesions are associated with increased cardiac events. Orbital atherectomy facilitates stent delivery and optimizes stent expansion by modifying severely calcified plaque. Outcomes in diabetic patients who undergo orbital atherectomy have not been reported. Our retrospective multicenter registry included 458 consecutive real-world patients with severely calcified coronary arteries who underwent orbital atherectomy. The primary safety endpoint was the rate of major adverse cardiac and cerebrovascular events at 30 days. Diabetics represented 42.1% (193/458) of the entire cohort. The primary endpoint was similar in diabetics and non-diabetics (1.0% vs. 3.0%%, P = 0.20), as were 30-day rates of death (0.5% vs. 1.9%, P = 0.41), myocardial infarction (0.5% vs. 1.5%, P = 0.40), target vessel revascularization (0% vs. 0%, P = 1), and stroke (0% vs. 0.4%, P > 0.9). Angiographic complications and stent thrombosis rate were low and did not differ between the 2 groups. Diabetics represented a sizeable portion of patients who underwent orbital atherectomy. Diabetics who had severely calcified coronary arteries and underwent orbital atherectomy had low event rates that were similar to non-diabetics. Orbital atherectomy appears to be a viable treatment strategy for diabetic patients. Randomized trials with longer-term follow-up are needed to determine the ideal treatment strategy for diabetics. © 2016, Wiley Periodicals, Inc.
Lee, Michael S; Shlofmitz, Evan; Kaplan, Barry; Shlofmitz, Richard
2016-04-01
We report the clinical outcomes of patients who underwent percutaneous coronary intervention (PCI) with orbital atherectomy for severely calcified unprotected left main coronary artery (ULMCA) disease. Although surgical revascularization is the gold standard for patients with ULMCA disease, not all patients are candidates for this. PCI is increasingly used to treat complex coronary artery disease, including ULMCA disease. The presence of severely calcified lesions increases the complexity of PCI. Orbital atherectomy can be used to facilitate stent delivery and expansion in severely calcified lesions. The clinical outcomes of patients treated with orbital atherectomy for severely calcified ULMCA disease have not been reported. From May 2014 to July 2015, a total of 14 patients who underwent PCI with orbital atherectomy for ULMCA disease were retrospectively evaluated. The primary endpoint was major cardiac and cerebrovascular event (cardiac death, myocardial infarction, stroke, and target-lesion revascularization) at 30 days. The mean age was 78.2 ± 5.8 years. The mean ejection fraction was 41.8 ± 19.8%. Distal bifurcation disease was present in 9 of 14 patients. Procedural success was achieved in all 14 patients. The 30-day major adverse cardiac and cerebrovascular event rate was 0%. One patient had coronary dissection that was successfully treated with stenting. No patient had perforation, slow flow, or thrombosis. Orbital atherectomy in patients with severely calcified ULMCA disease is feasible, even in high-risk patients who were considered poor surgical candidates. Randomized trials are needed to determine the role of orbital atherectomy in ULMCA disease.
Biodegradable metals for cardiovascular stents: from clinical concerns to recent Zn - alloys
Bowen, Patrick K.; Shearier, Emily R.; Zhao, Shan; Guillory, Roger J.; Zhao, Feng; Goldman, Jeremy; Drelich, Jaroslaw W.
2016-01-01
Metallic stents are commonly used to promote revascularization and maintain patency of plaqued or damaged arteries following balloon angioplasty. To mitigate the long-term side effects associated with corrosion-resistant stents (i.e. chronic inflammation and late stage thrombosis), a new generation of so-called “bioabsorbable” stents is currently being developed. The bioabsorbable coronary stents will corrode and be absorbed by the artery after completing their task as vascular scaffolding. Research spanning the last two decades has focused on biodegradable polymeric, iron-based, and magnesium-based stent materials. The inherent mechanical and surface properties of metals make them more attractive stent material candidates than their polymeric counterparts. Unfortunately, iron produces a voluminous, retained oxide product in the arterial wall, whereas magnesium and its alloys corrode too rapidly. A third class of metallic bioabsorbable materials that are based on zinc has been introduced in the last few years. As summarized in this contribution, this new zinc-based class of materials demonstrates the potential for an absorbable metallic stent with the mechanical and biodegradation characteristics required for optimal stent performance. They appear to be free of flaws that limit the application of iron- and magnesium-based alloys, and polymers. This review compares bioabsorbable materials and summarizes progress towards bioabsorbable stents. It emphasizes on current understanding of physiological and biological benefits of zinc and its biocompatibility. Finally, the review provides an outlook on challenges in designing zinc-based stents of optimal mechanical properties and biodegradation rate. PMID:27094868
Lee, Thung-Lip; Hsuan, Chin-Feng; Shih, Chen-Hsiang; Liang, Huai-Wen; Tsai, Hsing-Shan; Tseng, Wei-Kung; Hsu, Kwan-Lih
2017-02-10
Blunt cardiac trauma encompasses a wide range of clinical entities, including myocardial contusion, cardiac rupture, valve avulsion, pericardial injuries, arrhythmia, and even myocardial infarction. Acute myocardial infarction due to coronary artery dissection after blunt chest trauma is rare and may be life threatening. Differential diagnosis of acute myocardial infarction from cardiac contusion at this setting is not easy. Here we demonstrated a case of blunt chest trauma, with computed tomography detected myocardium enhancement defect early at emergency department. Under the impression of acute myocardial infarction, emergent coronary angiography revealed left anterior descending artery occlusion. Revascularization was performed and coronary artery dissection was found after thrombus aspiration. Finally, the patient survived after coronary stenting. Perfusion defects of myocardium enhancement on CT after blunt chest trauma can be very helpful to suggest myocardial infarction and facilitate the decision making of emergent procedure. This valuable sign should not be missed during the initial interpretation.
Kiss, Gabor; Corre, Olivier; Gueret, Gildas; Nguyen Ba, Vinh; Gilard, Martine; Boschat, Jaques; Arvieux, Charles Chistian
2009-01-01
Cardiopulmonary resuscitation guidelines imply the use of epinephrine/adrenaline during cardiopulmonary arrest. However, in cardiac arrest situations resulting from coronary artery spasm (CAS), the use of epinephrine/adrenaline could be deleterious. A 49-year-old patient underwent an emergency coronarography with an attempt to stent the coronary arteries. Radiologic imaging revealed a positive methylergonovine maleate (Methergine, Novartis Pharmaceuticals, East Hanover, NJ) test, with subocclusive CAS in several coronary vessels leading to electromechanical dissociation. Cardiopulmonary resuscitation was performed, and intracoronary boluses of isosorbide dinitrate were given to treat CAS. Epinephrine/adrenaline was not administered during resuscitation. Spontaneous circulation was obtained after cardioversion for ventricular fibrillation, and the patient progressively regained consciousness. Resuscitation guidelines do not specify the use of trinitrate derivatives in cardiac arrest situations caused by CAS. The pros and cons of the use of nitrates and epinephrine/adrenaline during cardiac arrest caused by CAS are analyzed in this case report.
The new era of cardiac surgery: hybrid therapy for cardiovascular disease.
Solenkova, Natalia V; Umakanthan, Ramanan; Leacche, Marzia; Zhao, David X; Byrne, John G
2010-11-01
Surgical therapy for cardiovascular disease carries excellent long-term outcomes but it is relatively invasive. With the development of new devices and techniques, modern cardiovascular surgery is trending toward less invasive approaches, especially for patients at high risk for traditional open heart surgery. A hybrid strategy combines traditional surgical treatments performed in the operating room with treatments traditionally available only in the catheterization laboratory with the goal of offering patients the best available therapy for any set of cardiovascular diseases. Examples of hybrid procedures include hybrid coronary artery bypass grafting, hybrid valve surgery and percutaneous coronary intervention, hybrid endocardial and epicardial atrial fibrillation procedures, and hybrid coronary artery bypass grafting/carotid artery stenting. This multidisciplinary approach requires strong collaboration between cardiac surgeons, vascular surgeons, and interventional cardiologists to obtain optimal patient outcomes.
Surgical treatment for Ellis type 3 coronary perforation during percutaneous catheter intervention.
Totsugawa, Toshinori; Kuinose, Masahiko; Yoshitaka, Hidenori; Katayama, Keijiro; Tsushima, Yoshimasa; Ishida, Atsuhisa; Chikazawa, Genta; Hiraoka, Arudo
2012-01-01
Coronary perforation (CP) is a rare, but sometimes lethal, complication of percutaneous catheter intervention (PCI). We reviewed surgically-treated cases of type 3 CP during PCI. From 2007 to 2010, 5 patients underwent surgical repair for type 3 CP (3 men, 2 women; mean age, 74 years). The mean number of diseased coronary branches was 2.6 and the mean SYNTAX score was 45. The target lesions were the left anterior descending artery in 4 cases and the right coronary artery in 1 case. Types of American Heart Association/American College of Cardiology classification were type B2 in only one case and type C in 4 cases. The causes of perforation were balloon inflation in 4 patients and rotational atherectomy in 1 patient. The in-hospital mortality rate was 20%. In the cases of CP associated with balloon inflation, coronary lacerations were so severe that re-bleeding occurred even if the covered stent could temporarily achieve hemostasis, and percutaneous cardiopulmonary support and emergency surgery were required. CP induced by balloon inflation tends to result in a serious condition compared with rotablator-induced CP. Surgery should be immediately performed even after covered stent implantation if there is any possibility of re-bleeding in the case of balloon-induced type 3 CP.
Hou, Xuwei; Jiang, Yu; Wang, Ningfu; Shen, Yun; Wang, Xiaoyan; Zhong, Yigang; Xu, Peng; Zhou, Liang
2015-01-01
Abstract The role of diagonal ear lobe crease (DELC) in coronary artery disease (CAD) diagnosis and prognosis remains controversial. In this study, we aimed to assess the combined effect of DELC with other conventional risk factors in the diagnosis and prognosis of CAD in Chinese patients who underwent angiography and coronary stent implantation. The study consisted of 956 consecutive patients who underwent angiography. The DELC was identified as no DELC, unilateral, and bilateral DELC. The conventional risk factors for CAD were recorded. Our dada showed that the overall presence of DELC is associated with CAD risk. Stratification analyses revealed that the diagnostic value of DELC was mostly significant in those with >4 risk factors. Also in patients with >4 risk factors, the presence of bilateral DELC remains to be associated with higher hs-CRP level, higher severity of CAD, and higher possibility of developing major adverse cardiac events after successful percutaneous coronary intervention (PCI). Our study confirmed the relation of DELC with CAD in Chinese patients; more importantly, our data suggest the combination of DELC and CAD risk factors will help to predict the incidence of CAD and may predict the prognosis after successfully PCI. PMID:26131833
Percutaneous Transluminal Cerebral Angioplasty and Stenting in Acute Vertebrobasilar Ischemic Stroke
Nistri, M.; Mangiafico, S.; Cellerini, M.; Villa, G.; Mennonna, P.; Ammannati, F.; Giordano, G. P.
2002-01-01
Summary Reports of cerebral transluminal angioplasty and stenting in patients with vertebrobasilar ischemic stroke are scanty. Herein we report on the use of “monorail” coronary balloon angioplasty and stent balloon mounted catheters in two patients with acute vertebrobasilar ischemic stroke, focussing on the differences and possible advantages of the “monorail” technique in comparison with the “over-the-wire” technique. In both patients, the clinical picture was characterized by progressive brainstem symptoms followed by acute loss of consciousness related to an atherothrombotic occlusion and subocclusion of the dominant intracranial vertebral artery, respectively. In one patient, superselective thrombolytic therapy and balloon angioplasty resulted in a dissection flap at the vertebrobasilar junction. The latter was treated by successful deployment of a coronary stent. In the other patient, the subocclusive lesion was directly treated by angioplasty and stenting without thrombolytic therapy. The clinical outcome was poor for one patient (“locked in” syndrome) while the other had a complete clinical recovery. In acute atherothrombotic vertebrobasilar stroke transluminal cerebral angioplasty and stenting may be successfully performed allowing vessel recanalization. PMID:20594522
Detailing radio frequency heating induced by coronary stents: a 7.0 Tesla magnetic resonance study.
Santoro, Davide; Winter, Lukas; Müller, Alexander; Vogt, Julia; Renz, Wolfgang; Ozerdem, Celal; Grässl, Andreas; Tkachenko, Valeriy; Schulz-Menger, Jeanette; Niendorf, Thoralf
2012-01-01
The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF) power deposition at 7.0 T and bears the potential to induce local heating, which might cause tissue damage. Realizing these constraints, this work examines RF heating effects of stents using electro-magnetic field (EMF) simulations and phantoms with properties that mimic myocardium. For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. The results demonstrate an agreement between RF heating induced temperature changes derived from EMF simulations versus MR thermometry. The birdcage coil tailored for RF heating was capable of irradiating power exceeding the specific-absorption rate (SAR) limits defined by the IEC guidelines by a factor of three. This setup afforded RF induced temperature changes up to +27 K in a reference phantom. The maximum extra temperature increase, induced by a copper tube or a coronary stent was less than 3 K. The coronary stents examined showed an RF heating behavior similar to a copper tube. Our results suggest that, if IEC guidelines for local/global SAR are followed, the extra RF heating induced in myocardial tissue by stents may not be significant versus the baseline heating induced by the energy deposited by a tailored cardiac transmit RF coil at 7.0 T, and may be smaller if not insignificant than the extra RF heating observed under the circumstances used in this study.
Detailing Radio Frequency Heating Induced by Coronary Stents: A 7.0 Tesla Magnetic Resonance Study
Santoro, Davide; Winter, Lukas; Müller, Alexander; Vogt, Julia; Renz, Wolfgang; Özerdem, Celal; Grässl, Andreas; Tkachenko, Valeriy; Schulz-Menger, Jeanette; Niendorf, Thoralf
2012-01-01
The sensitivity gain of ultrahigh field Magnetic Resonance (UHF-MR) holds the promise to enhance spatial and temporal resolution. Such improvements could be beneficial for cardiovascular MR. However, intracoronary stents used for treatment of coronary artery disease are currently considered to be contra-indications for UHF-MR. The antenna effect induced by a stent together with RF wavelength shortening could increase local radiofrequency (RF) power deposition at 7.0 T and bears the potential to induce local heating, which might cause tissue damage. Realizing these constraints, this work examines RF heating effects of stents using electro-magnetic field (EMF) simulations and phantoms with properties that mimic myocardium. For this purpose, RF power deposition that exceeds the clinical limits was induced by a dedicated birdcage coil. Fiber optic probes and MR thermometry were applied for temperature monitoring using agarose phantoms containing copper tubes or coronary stents. The results demonstrate an agreement between RF heating induced temperature changes derived from EMF simulations versus MR thermometry. The birdcage coil tailored for RF heating was capable of irradiating power exceeding the specific-absorption rate (SAR) limits defined by the IEC guidelines by a factor of three. This setup afforded RF induced temperature changes up to +27 K in a reference phantom. The maximum extra temperature increase, induced by a copper tube or a coronary stent was less than 3 K. The coronary stents examined showed an RF heating behavior similar to a copper tube. Our results suggest that, if IEC guidelines for local/global SAR are followed, the extra RF heating induced in myocardial tissue by stents may not be significant versus the baseline heating induced by the energy deposited by a tailored cardiac transmit RF coil at 7.0 T, and may be smaller if not insignificant than the extra RF heating observed under the circumstances used in this study. PMID:23185498
Eric Jones, John; Chen, Meng; Yu, Qingsong
2014-10-01
To improve their corrosion resistance and thus long-term biocompatibility, 316L stainless steel coronary artery stents were coated with trimethylsilane (TMS) plasma coatings of 20-25 nm in thickness. Both direct current (DC) and radio-frequency (RF) glow discharges were utilized for TMS plasma coatings and additional NH₃/O₂ plasma treatment to tailor the surface properties. X-ray photoelectron spectroscopy (XPS) was used to characterize the coating surface chemistry. It was found that both DC and RF TMS plasma coatings had Si- and C-rich composition, and the O- and N-contents on the surfaces were substantially increased after NH₃/O₂ plasma treatment. Surface contact angle measurements showed that DC TMS plasma nanocoating with NH₃/O₂ plasma treatment generated very hydrophilic surface. The corrosion resistance of TMS plasma coated stents was evaluated through potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) techniques. The potentiodynamic polarization demonstrated that the TMS plasma coated stents imparted higher corrosion potential and pitting potential, as well as lower corrosion current densities as compared with uncoated controls. The surface morphology of stents before and after potentiodynamic polarization testing was analyzed with scanning electron microscopy, which indicated less corrosion on coated stents than uncoated controls. It was also noted that, from EIS data, the hydrophobic TMS plasma nanocoatings showed stable impedance modulus at 0.1 Hz after 21 day immersion in an electrolyte solution. These results suggest improved corrosion resistance of the 316L stainless steel stents by TMS plasma nanocoatings and great promise in reducing and blocking metallic ions releasing into the bloodstream. © 2014 Wiley Periodicals, Inc.
Pliam, Michael B; Zapolanski, Alex; Anastassiou, Peter; Ryan, Colman J; Manila, Louis L; Shaw, Richard E; Pira, Bob-Kenneth
2007-09-01
: There has been little emphasis on the possible consequences of prior stent placement on the outcome of coronary bypass surgery (CABG). We compared the results of isolated CABG patients who had prior stents with those who had not with respect to preoperative status, operative procedure, and postoperative immediate and long-term outcome. : Records of 1471 patients undergoing isolated CABG at our institution between January 1, 2000, and March 31, 2005, were reviewed. Patients were divided into three groups. Group I had no stents (n = 1317). Group II had one to three stents (n = 137). Group III had more than three stents (n = 17). Groups were compared with respect to preoperative risk factors, operative procedures, and postoperative results. Long-term survival data were obtained on 97.6% of patients with a mean follow-up, 4.1 ± 2.3 years. : Stented patients were younger (66.1 ± 10.8 vs. 69.1 ± 10.8 years, P = 0.006), had more unstable angina (68.2% vs. 58.9%, P = 0.02), hypercholesterolemia (83.8% vs. 61.2%, P = 0.00), chronic obstructive pulmonary disease (13.6% vs. 8.4%, P = 0.03), peripheral vascular disease (15.2% vs. 8.4%, P = 0.00), and previous CABG (10.1% vs. 4.2%, P = 0.00), fewer low ejection fractions (1.3% vs. 5.2%, P = 0.02), left main disease (25.3% vs. 32.6%, P = 0.04), diabetes (31.2% vs. 40.8%, P = 0.01), or diffuse disease (19.5 ± 10.5 vs. 22.5 ± 10.9, P = 0.00), had more off pump procedures (53.2% vs. 45.3%, P = 0.03), fewer internal thoracic artery grafts (80.5% vs. 86.6%, P = 0.03), fewer grafts placed (>3: 52.6% vs. 61.8%, P = 0.02), more complications (76.5% vs. 42.6%, P = 0.005), atrial fibrillation (47.1% vs. 19.7%, P = 0.011), longer hospital stays (12.2 vs. 8.3 days, P = 0.019). Percentage survival for groups I, II, and III at 60 months was 82.1%, 84.7%, and 72.6%, respectively. : Stents placed before surgery in isolated CABG patients may be associated with higher preoperative risk, altered operative procedures, more postoperative complications, longer hospitalizations, and more readmissions. Overall, stented patients experienced more preoperative hospitalizations, catheterizations, and percutaneous coronary interventions (PCIs) than nonstented patients. Survival for those with more than three stents may be diminished.
Strategies for multivessel revascularization in patients with diabetes.
Farkouh, Michael E; Domanski, Michael; Sleeper, Lynn A; Siami, Flora S; Dangas, George; Mack, Michael; Yang, May; Cohen, David J; Rosenberg, Yves; Solomon, Scott D; Desai, Akshay S; Gersh, Bernard J; Magnuson, Elizabeth A; Lansky, Alexandra; Boineau, Robin; Weinberger, Jesse; Ramanathan, Krishnan; Sousa, J Eduardo; Rankin, Jamie; Bhargava, Balram; Buse, John; Hueb, Whady; Smith, Craig R; Muratov, Victoria; Bansilal, Sameer; King, Spencer; Bertrand, Michel; Fuster, Valentin
2012-12-20
In some randomized trials comparing revascularization strategies for patients with diabetes, coronary-artery bypass grafting (CABG) has had a better outcome than percutaneous coronary intervention (PCI). We sought to discover whether aggressive medical therapy and the use of drug-eluting stents could alter the revascularization approach for patients with diabetes and multivessel coronary artery disease. In this randomized trial, we assigned patients with diabetes and multivessel coronary artery disease to undergo either PCI with drug-eluting stents or CABG. The patients were followed for a minimum of 2 years (median among survivors, 3.8 years). All patients were prescribed currently recommended medical therapies for the control of low-density lipoprotein cholesterol, systolic blood pressure, and glycated hemoglobin. The primary outcome measure was a composite of death from any cause, nonfatal myocardial infarction, or nonfatal stroke. From 2005 through 2010, we enrolled 1900 patients at 140 international centers. The patients' mean age was 63.1±9.1 years, 29% were women, and 83% had three-vessel disease. The primary outcome occurred more frequently in the PCI group (P=0.005), with 5-year rates of 26.6% in the PCI group and 18.7% in the CABG group. The benefit of CABG was driven by differences in rates of both myocardial infarction (P<0.001) and death from any cause (P=0.049). Stroke was more frequent in the CABG group, with 5-year rates of 2.4% in the PCI group and 5.2% in the CABG group (P=0.03). For patients with diabetes and advanced coronary artery disease, CABG was superior to PCI in that it significantly reduced rates of death and myocardial infarction, with a higher rate of stroke. (Funded by the National Heart, Lung, and Blood Institute and others; FREEDOM ClinicalTrials.gov number, NCT00086450.).
Alurkar, Anand; Karanam, Lakshmi Sudha Prasanna; Shah, Shripal; Mare, Pandurang
2016-10-01
Familial Hypercholesterolaemia (FH) is a monogenic autosomal dominant disorder affecting 1 in 500 individuals. We report a case of 32-year-old female with FH, previously not on any treatment, who presented with recurrent bilateral Middle Cerebral Artery (MCA) territory strokes and dyspnoea on exertion due to severe panvascualar disease involving descending aorta, innominate, subclavian, common carotid, internal carotid and coronary vessels. Her complete clinical work up was done and was started on lipid lowering drug treatment and low calorie diet. She underwent simultaneous bilateral carotid stenting followed by coronary artery bypass surgery at a later date. In the present scenario we want to emphasize the importance of early detection and treatment of individuals with FH, failing of which results in premature and accelerated atherosclerosis causing multisystemic vascular disease with significant morbidity and mortality. Screening of first degree relatives is important owing to the autosomal dominant inheritance pattern of the FH.
Alurkar, Anand; Shah, Shripal; Mare, Pandurang
2016-01-01
Familial Hypercholesterolaemia (FH) is a monogenic autosomal dominant disorder affecting 1 in 500 individuals. We report a case of 32-year-old female with FH, previously not on any treatment, who presented with recurrent bilateral Middle Cerebral Artery (MCA) territory strokes and dyspnoea on exertion due to severe panvascualar disease involving descending aorta, innominate, subclavian, common carotid, internal carotid and coronary vessels. Her complete clinical work up was done and was started on lipid lowering drug treatment and low calorie diet. She underwent simultaneous bilateral carotid stenting followed by coronary artery bypass surgery at a later date. In the present scenario we want to emphasize the importance of early detection and treatment of individuals with FH, failing of which results in premature and accelerated atherosclerosis causing multisystemic vascular disease with significant morbidity and mortality. Screening of first degree relatives is important owing to the autosomal dominant inheritance pattern of the FH. PMID:27891422
Shugman, Ibrahim M; Hee, Leia; Mussap, Christian J; Diu, Patrick; Lo, Sidney; Hopkins, Andrew P; Nguyen, Phong; Taylor, David; Rajaratnam, Rohan; Leung, Dominic; Thomas, Liza; Juergens, Craig P; French, John K
2013-04-01
During percutaneous coronary intervention (PCI) performed in the emergent setting of ST-segment elevation myocardial infarction (STEMI), uncertainty about patients' ability to comply with 12 months dual antiplatelet therapy after drug-eluting stenting is common, and thus, selective bare-metal stent (BMS) deployment could be an attractive strategy if this achieved low target vessel revascularization (TVR) rates in large infarct-related arteries (IRAs) (≥3.5 mm). To evaluate this hypothesis, among 1,282 patients with STEMI who underwent PCI during their initial hospitalization, we studied 1,059 patients (83%) who received BMS, of whom 512 (48%) had large IRAs ≥3.5 mm in diameter, 333 (31%) had IRAs 3 to 3.49 mm, and 214 (20%) had IRAs <3 mm. At 1 year, TVR rate in patients with BMS was 5.8% (2.2% with large BMS [≥3.5 mm], 9.2% with BMS 3-3.49 mm [intermediate], and 9.0% with BMS <3.0 mm [small], P < .001). The rates of death/reinfarction among patients with large BMS compared with intermediate BMS or small BMS were lower (6.6% vs 11.7% vs 9.0%, P = .042). Among patients who received BMS, the independent predictors of TVR at 1 year were the following: vessel diameter <3.5 mm (odds ratio [OR] 4.39 [95% CI 2.24-8.60], P < .001), proximal left anterior descending coronary artery lesions (OR 1.89 [95% CI 1.08-3.31], P = .027), hypertension (OR 2.01 [95% CI 1.17-3.438], P = .011), and prior PCI (OR 3.46 [95% CI 1.21-9.85], P = .02). The predictors of death/myocardial infarction at 1 year were pre-PCI cardiogenic shock (OR 8.16 [95% CI 4.16-16.01], P < .001), age ≥65 years (OR 2.63 [95% CI 1.58-4.39], P < .001), left anterior descending coronary artery culprit lesions (OR 1.95 [95% CI 1.19-3.21], P = .008), female gender (OR 1.93 [95% CI 1.12-3.32], P = .019), and American College of Cardiology/American Heart Association lesion classes B2 and C (OR 2.17 [95% CI 1.10-4.27], P = .026). Bare-metal stent deployment in STEMI patients with IRAs ≥3.5 mm was associated with low rates of TVR. Their use in this setting warrants comparison with second-generation drug-eluting stenting deployment in future randomized clinical trials. Copyright © 2013 Mosby, Inc. All rights reserved.
Fracture, inflation and floatation embolisation of PTCA balloon.
O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick
2015-01-09
This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in 'inflation' of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing 'floatation' embolisation into the coronary artery. 2015 BMJ Publishing Group Ltd.
Fracture, inflation and floatation embolisation of PTCA balloon
O'Neill, Louisa; Sowbhaga, Vinay; Owens, Patrick
2015-01-01
This case outlines an unusual complication of coronary intervention, the likely mechanisms leading to this and possible retrieval options. It is the first case to the best of our knowledge reporting this complication. A 78-year-old Caucasian man underwent coronary stenting. During the procedure kinking and subsequent fracture of a non-compliant percutaneous transluminal coronary angioplasty (PTCA) balloon occurred. Injection of contrast down the guide to opacify the coronary arteries resulted in ‘inflation’ of the balloon with air, and embolisation of the inflated balloon into the proximal left anterior descending artery. The embolised balloon was retrieved by removal of the guide catheter and wire as a unit. The patient had a good angiographic outcome. This case highlights risks associated with usage of kinked balloons catheters, and describes for the first time to our knowledge, the inflation of a PTCA balloon with air from its shaft within the catheter, causing ‘floatation’ embolisation into the coronary artery. PMID:25576524
Kimura, Takeshi; Morimoto, Takeshi; Nakagawa, Yoshihisa; Kawai, Kazuya; Miyazaki, Shunichi; Muramatsu, Toshiya; Shiode, Nobuo; Namura, Masanobu; Sone, Takahito; Oshima, Shigeru; Nishikawa, Hideo; Hiasa, Yoshikazu; Hayashi, Yasuhiko; Nobuyoshi, Masakiyo; Mitudo, Kazuaki
2012-01-31
There is a scarcity of long-term data from large-scale drug-eluting stent registries with a large enough sample to evaluate low-frequency events such as stent thrombosis (ST). Five-year outcomes were evaluated in 12 812 consecutive patients undergoing sirolimus-eluting stent (SES) implantation in the j-Cypher registry. Cumulative incidence of definite ST was low (30 day, 0.3%; 1 year, 0.6%; and 5 years, 1.6%). However, late and very late ST continued to occur without attenuation up to 5 years after sirolimus-eluting stent implantation (0.26%/y). Cumulative incidence of target lesion revascularization within the first year was low (7.3%). However, late target lesion revascularization beyond 1 year also continued to occur without attenuation up to 5 years (2.2%/y). Independent risk factors of ST were completely different according to the timing of ST onset, suggesting the presence of different pathophysiological mechanisms of ST according to the timing of ST onset: acute coronary syndrome and target of proximal left anterior descending coronary artery for early ST; side-branch stenting, diabetes mellitus, and end-stage renal disease with or without hemodialysis for late ST; and current smoking and total stent length >28 mm for very late ST. Independent risk factors of late target lesion revascularization beyond 1 year were generally similar to those risk factors identified for early target lesion revascularization. Late adverse events such as very late ST and late target lesion revascularization are continuous hazards, lasting at least up to 5 years after implantation of the first-generation drug-eluting stents (sirolimus-eluting stents), which should be the targets for developing improved coronary stents.
Furukawa, Nobuyuki; Scholtz, Werner; Haas, Nikolaus; Ensminger, Stephan; Gummert, Jan; Börgermann, Jochen
2015-01-01
An 81-year-old man with high-grade aortic valve stenosis and status post-coronary artery bypass grafting and supracoronary replacement of the ascending aorta was referred for transcatheter aortic valve implantation. He was in New York Heart Association class III and had dyspnea. After appropriate screening, we implanted a 29-mm SAPIEN XT valve (Edwards Lifesciences, Irvine, CA USA) through a transapical approach because of severe peripheral arterial occlusive disease. Postinterventional aortography revealed correct positioning and function of the valve and free coronary ostia but contrast extravasation in the vicinity of the interposed vascular prosthesis, resulting in severe luminal narrowing. We chose to manage the stenosis with an endovascular stent. After stenting, extravascular compression was markedly reduced, and the pressure gradient disappeared. The patient was discharged home on the 20th postoperative day. Three months later, computed tomography depicted correct positioning of both grafts. The patient's general health is good, and he is now in New York Heart Association class II. This case illustrates a complication of transcatheter aortic valve implantation specific for patients with an ascending aortic graft. Although stenting may be a good solution, as depicted by this case, self-expanding transcatheter aortic valves should be preferred in patients with ascending aortic grafts to avoid the described complication.
2018-01-01
Revascularization of severe left main and multivessel coronary artery disease has been shown to improve survival in both stable ischemic heart disease and acute coronary syndrome. While revascularization with coronary artery bypass surgery for these disease entities carries class I recommendation in most current guidelines, recent trials has shown potential comparable survival and cardiovascular outcomes between percutaneous and surgical interventions in patients with less complex coronary anatomy. Despite the conflicting results observed in the most recent left main revascularization trials, Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease (EXCEL) and Nordic-Baltic-British left main revascularization (NOBLE), both treatment strategies remain important for the management of left main disease (LMD) and multivessel disease (MVD) reflecting on the importance of heart team discussion. This review is focused on revascularization of LMD and MVD in patients who are not presenting with ST-segment elevation myocardial infarction, encompassing the evidence from historic and contemporary trials which shaped up current practices. This review discusses the heart team approach to guide decision making, including special populations that are not represented in clinical trials. PMID:29856140
Al-Hijji, Mohammed; El Sabbagh, Abdallah; Holmes, David R
2018-06-01
Revascularization of severe left main and multivessel coronary artery disease has been shown to improve survival in both stable ischemic heart disease and acute coronary syndrome. While revascularization with coronary artery bypass surgery for these disease entities carries class I recommendation in most current guidelines, recent trials has shown potential comparable survival and cardiovascular outcomes between percutaneous and surgical interventions in patients with less complex coronary anatomy. Despite the conflicting results observed in the most recent left main revascularization trials, Everolimus-Eluting Stents or Bypass Surgery for Left Main Coronary Artery Disease (EXCEL) and Nordic-Baltic-British left main revascularization (NOBLE), both treatment strategies remain important for the management of left main disease (LMD) and multivessel disease (MVD) reflecting on the importance of heart team discussion. This review is focused on revascularization of LMD and MVD in patients who are not presenting with ST-segment elevation myocardial infarction, encompassing the evidence from historic and contemporary trials which shaped up current practices. This review discusses the heart team approach to guide decision making, including special populations that are not represented in clinical trials. Copyright © 2018. The Korean Society of Cardiology.
Benchmark for Numerical Models of Stented Coronary Bifurcation Flow.
García Carrascal, P; García García, J; Sierra Pallares, J; Castro Ruiz, F; Manuel Martín, F J
2018-09-01
In-stent restenosis ails many patients who have undergone stenting. When the stented artery is a bifurcation, the intervention is particularly critical because of the complex stent geometry involved in these structures. Computational fluid dynamics (CFD) has been shown to be an effective approach when modeling blood flow behavior and understanding the mechanisms that underlie in-stent restenosis. However, these CFD models require validation through experimental data in order to be reliable. It is with this purpose in mind that we performed particle image velocimetry (PIV) measurements of velocity fields within flows through a simplified coronary bifurcation. Although the flow in this simplified bifurcation differs from the actual blood flow, it emulates the main fluid dynamic mechanisms found in hemodynamic flow. Experimental measurements were performed for several stenting techniques in both steady and unsteady flow conditions. The test conditions were strictly controlled, and uncertainty was accurately predicted. The results obtained in this research represent readily accessible, easy to emulate, detailed velocity fields and geometry, and they have been successfully used to validate our numerical model. These data can be used as a benchmark for further development of numerical CFD modeling in terms of comparison of the main flow pattern characteristics.
Haine, Steven; Wouters, Kristien; Miljoen, Hielko; Vandendriessche, Tom; Claeys, Marc; Bosmans, Johan; Vrints, Christiaan
2018-04-01
Since neointima smooth muscle cells (SMC) mainly originate from the vessel wall, we investigated whether atherosclerotic plaque composition influences subsequent in-stent neointima proliferation and restenosis. We performed intravascular ultrasound (IVUS) with virtual histology in 98 patients prior to elective bare-metal stent (BMS) implantation in de novo coronary artery lesions. Virtual histology variables pre-percutaneous coronary intervention (PCI) were related to in-stent neointima proliferation six months after implantation assessed as late luminal loss of 0.88 mm (interquartile range (IQR) 0.37-1.23 mm) on angiography and as maximal percentage area stenosis of 42% (IQR 33-59%) and percentage volume intima hyperplasia of 27% (IQR 20-36%) on IVUS. A ridge-trace based multiple linear regression model was constructed to account for multicollinearity of the virtual histology variables and was corrected for implanted stent length (18 mm, IQR 15-23 mm), stent diameter (3.0 mm, IQR 2.75-3.5 mm) and lesion volume (146 mm³, IQR 80-201 mm³) prior to PCI. Fibrous tissue volume prior to PCI (49 mm³, IQR 30-77 mm³) was significantly and independently related to late luminal loss (p = .038), maximal percentage area stenosis (p = .041) and percentage volume intima hyperplasia (p = .004). Neither absolute nor relative amounts of fibrofatty, calcified or necrotic core tissue appeared related to any of the restenosis parameters. Subgroup analysis after exclusion of acute coronary syndrome (ACS) patients yielded similar results. Lesions with more voluminous fibrotic tissue pre-PCI show more pronounced in-stent neointima proliferation, even after correction for lesion plaque volume.
Simka, Marian; Brzegowy, Paweł; Janas, Piotr; Kazibudzki, Marek; Pieniążek, Piotr; Ochała, Andrzej; Popiela, Tadeusz; Mrowiecki, Tomasz
2017-01-01
Introduction Although surgical endarterectomy remains the treatment of choice for carotid artery stenosis, stenting plays an important role as an alternative treatment modality, especially in high-risk patients. The actual safety profile associated with stenting procedures is probably better than that reported by randomized controlled trials. Aim To assess the safety of stent implantations in extracranial arteries supplying the brain, and also to identify risk factors associated with this procedure. Material and methods This was a post hoc analysis, with 30-day follow-up. We analyzed the results of treatment of 372 patients who underwent 408 procedures, 197 such procedures in asymptomatic, and 211 in symptomatic individuals. Stenting procedures were performed using a technique and armamentarium which were tailored to the type and anatomy of lesions. Results There were 6 (1.5%) strokes, including 2 (0.5%) major strokes, 1 ipsi- and 1 contralateral, and 4 (1.0%) minor strokes. In asymptomatic patients there was 1 (0.3%) minor stroke. Transient ischemic attacks occurred in 5 (1.2%) patients. There were 2 (0.5%) non-STEMI myocardial infarctions and 2 (0.5%) non-stroke related fatalities. Risk factors of these adverse events were diabetes mellitus, lesions localized in a tortuous segment of the artery, embolic material in the filter and bilateral stenoses of carotid arteries. Additional risk factors in asymptomatic patients were renal impairment and advanced coronary artery disease; and in symptomatic patients, grade 3 arterial hypertension, dislipidemia, cigarette smoking and lesions requiring predilatation. Conclusions Stenting procedures of extracranial arteries supplying the brain, which are tailored to the type and anatomy of lesions, seem to be relatively safe. PMID:28344618
Latacz, Paweł; Simka, Marian; Brzegowy, Paweł; Janas, Piotr; Kazibudzki, Marek; Pieniążek, Piotr; Ochała, Andrzej; Popiela, Tadeusz; Mrowiecki, Tomasz
2017-01-01
Although surgical endarterectomy remains the treatment of choice for carotid artery stenosis, stenting plays an important role as an alternative treatment modality, especially in high-risk patients. The actual safety profile associated with stenting procedures is probably better than that reported by randomized controlled trials. To assess the safety of stent implantations in extracranial arteries supplying the brain, and also to identify risk factors associated with this procedure. This was a post hoc analysis, with 30-day follow-up. We analyzed the results of treatment of 372 patients who underwent 408 procedures, 197 such procedures in asymptomatic, and 211 in symptomatic individuals. Stenting procedures were performed using a technique and armamentarium which were tailored to the type and anatomy of lesions. There were 6 (1.5%) strokes, including 2 (0.5%) major strokes, 1 ipsi- and 1 contralateral, and 4 (1.0%) minor strokes. In asymptomatic patients there was 1 (0.3%) minor stroke. Transient ischemic attacks occurred in 5 (1.2%) patients. There were 2 (0.5%) non-STEMI myocardial infarctions and 2 (0.5%) non-stroke related fatalities. Risk factors of these adverse events were diabetes mellitus, lesions localized in a tortuous segment of the artery, embolic material in the filter and bilateral stenoses of carotid arteries. Additional risk factors in asymptomatic patients were renal impairment and advanced coronary artery disease; and in symptomatic patients, grade 3 arterial hypertension, dislipidemia, cigarette smoking and lesions requiring predilatation. Stenting procedures of extracranial arteries supplying the brain, which are tailored to the type and anatomy of lesions, seem to be relatively safe.
Risk of no-reflow in culprit lesion versus culprit vessel PCI in acute STEMI.
Arslan, Uğur; Yaman, Mehmet; Kocaoğlu, İbrahim; Turan, Oğuzhan Ekrem; Yücel, Huriye; Aksakal, Aytekin; Günaydin, İlksen Atasoy; Hakan Ateş, Ahmet
2015-09-01
The present report describes patients with acute ST-elevation myocardial infarction who had at least two lesions in the culprit vessel (CV) during primary percutaneous coronary intervention (PCI). Here, we aimed to examine two different strategies, namely, PCI of only culprit lesion (CL) versus PCI of all lesions in the CV in the setting of acute ST-elevation myocardial infarction. Patients who underwent primary PCI were examined for the presence of an additional lesion in the infarct-related artery and divided into two groups according to the PCI strategy: CV versus CL groups. Coronary angiograms were examined for coronary thrombolysis in myocardial infarction (TIMI) flow and major clinical outcomes were determined. Of 637 patients, 472 (74.1%) underwent primary PCI for the CV (CV group) and 165 (25.9%) underwent primary PCI only for CL (CL group). TIMI flow before primary PCI and after stenting of the CL was similar; however, TIMI flow after completion of the procedure was significantly better in the CL group (P=0.022). The composite of death, nonfatal myocardial infarction and repeat revascularization was significantly better in the CL group (P=0.041) and early stent thrombosis was observed more commonly in the CV group [14 (3.0%) patients vs. 1 (0.6%) patient, P=0.09]. In the presence of an additional lesion in the CV during primary PCI, deferring stenting for the non-CL in the culprit artery after stenting the CL may be considered to prevent the development of no-reflow or slow-reflow, and thus major clinical adverse events may be reduced.
Centurión Md PhD Facc, Osmar Antonio
2014-01-01
The necessity to add two antiplatelet agents to an oral anticoagulant (OAC) often arises in patients with atrial fibrillation (AF) in routine clinical practice. The majority of AF patients have an indication for continuous OAC, and coronary artery disease co-exists in 25% of these patients. The increasing use of drug-eluting stents to minimize intrastent restenosis necessitates long-term dual antiplatelet therapy with Aspirin plus Clopidogrel to reduce the risk of early and late stent thrombosis. Combined aspirin-clopidogrel therapy, however, is less effective in preventing stroke compared with OAC alone in AF patients, and OAC alone is insufficient to prevent stent thrombosis. The management of AF patients presenting with an acute coronary syndrome poses similar management complexities. Since AF and coronary artery disease with stent placement are common, it is relatively frequent to treat patients with both these conditions, where triple antithrombotic therapy with Aspirin, Clopidogrel and an OAC would be needed. Dabigatran etexilate, an oral direct thrombin inhibitor, has shown that compared with Warfarin given at a dose of 150 mg twice daily significantly reduces stroke with less intracranial bleeding, and at a dose of 110 mg twice daily has similar efficacy with less bleeding. Although, Dabigatran maintained its overall favorable profile compared with Warfarin in patients on dual antiplatelet therapy, we should always bear in mind for the sake of our AF patients that combining dual antiplatelet therapy with chronic anticoagulation with Dabigatran, as well as with Warfarin, significantly increases bleeding risk. This triple therapy association should be evaluated in the individual patient after carefully balancing bleeding versus thrombotic risk.
[Myocardial bridge as the only cause of acute coronary syndrome among the young patients].
Miakinkova, Liudmila O; Teslenko, Yurii V; Tsyhanenko, Irina V
2018-01-01
Introduction: Myocardial bridge is an inborn anomaly of coronary artery development, when a part of it is submerged in a myocard, which is pressing the coronary artery to a systola and restrains coronary blood circulation. Generally this feature of coronary blood circulation does not cause any clinical symptoms because the 85% of coronary blood stream of the left ventricle is provided by diastolic filling. Hemodynamic changes in atherosclerosis, tahicardie, hypertrophie of myocard are leading to the manifestation of clinical symptoms of ischemia. The aim: The purpose of the investigation was to discover the features of clinical development of acute coronary syndrome caused by myocardial bridge of young patients without the features of atherosclerotical harm of coronary arteries. Materials and methods: Eight causes of acute coronary syndrome among patients of 28±8,5 years with myocardial bridge which was revealed during coronary angiography, were investigated. Standardized examination and conservative treatment of patients was held, except for three who have got interventional therapy. Results: According to our investigation, myocardial bridge of all investigated patients was located in the middle of the third front interventricular branch of the left coronary artery. Causes of acute coronary syndrome manifestation were tahicardia, spasms of coronary artery, inducted by iatrogenic factors hypertrophie of myocard, hypertrophic cardiomyopatie. Connection between the manifestation of clinical symptoms and length of tunneled segment which did not depend on the level of systolic compres was discovered. The results of conservative and interventional treatment were analyzed. Conclusions: Myocardial bridge can be the cause of myocardial ischemia among patients without signs of coronary atherosclerosis with additional hemodynamic risk facts such as tahicardia, spasms of coronary artery, hypertrophie of myocard. Clinical symptomatology of the acute coronary syndrome is more often observed among patients who's myocsrdial bridge is located in the middle of the third front interventricular branch of the left coronary artery. This is caused by perpendicular location of muscle fibers to coronary artery that increases systolic compression. Diastolic function and blood filling of coronary artery can be improved due to the medication beta-blockers therapy of patients with symptomatic myocardial bridge. A higher risk of appearance of restenosis of the stent is possible due to interventional treatment of young patients with myocardial bridge without atherosclerosis of coronary arteries.
Bouki, Konstantina P; Sakkali, Eleni; Toutouzas, Konstantinos; Vlad, Delia; Barmperis, Dimitrios; Phychari, Stavroula; Riga, Maria; Apostolou, Thomas; Stefanadis, Christodoulos
2015-08-01
The purpose of the present study was to assess the incidence, predictors and long term prognosis of stent edge dissections identified by (OCT) after the implantation of bare metal (BMS) and drug eluting stents (DES). We studied 74 patients who underwent percutaneous coronary intervention (PCI) because of an acute coronary syndrome. Edge dissections were found in 29 of 74 patients (39.1%). Independent predictors of edge dissections were: the presence of ST-elevation myocardial infarction (STEMI) (P = 0.005, odds ratio 11.78; 95% Cl 2.06-67.10), the small reference lumen diameter (P = 0.009, odds ratio 0.11; 95% Cl 0.02-0.58) and the short stents implanted (P = 0.013, odds ratio 0.83; 95% Cl 0.72-0.96). During a follow-up period of 25.6 ± 9.4 months 11 patients presented with at least one major adverse cardiac event. Event free survival was significantly decreased in patients with edge dissection with a flap thickness >0.31 mm compared to patients with thinner flap or without any dissection (P < 0.001). OCT frequently detects edge dissections, usually related to STEMI presentation and to PCI technique. Deep vessel wall injury at stent edges with a dissection flap thickness more than 0.31mm carries an adverse clinical impact on long-term clinical outcome. © 2015 Wiley Periodicals, Inc.
Franchi, Francesco; Rollini, Fabiana; Angiolillo, Dominick J
2014-11-01
To provide an updated overview on the management of antiplatelet therapy in patients with coronary stents undergoing cardiac and noncardiac surgery. Surgical procedures are frequently performed in patients with coronary stents and are associated with an increased risk of ischemic and bleeding complications in the perioperative period. Given the lack of well-designed prospective randomized trials, guidelines recommendations are currently derived from observational studies and expert consensus. Defining the optimal balance between the risk of thrombotic events following discontinuation of antiplatelet therapy and the risk of hemorrhagic complications of having a surgical procedure while on antiplatelet therapy is pivotal. Elective surgery should be postponed for at least 4 weeks after bare metal stent implantation and 6-12 months after drug-eluting stent. If this is not possible, aspirin should be continued in the perioperative period, although the management of P2Y₁₂ inhibitors should be individualized according to the individual patient and type of surgery. In the absence of well-defined recommendations deriving from prospective randomized clinical trials, the perioperative management of antiplatelet therapy should be based on the balance between the specific thrombotic and hemorrhagic risks that characterize each patient and each surgical procedure.
Krenn, Lisa; Kopp, Christoph; Glogar, Dietmar; Lang, Irene M; Delle-Karth, Georg; Neunteufl, Thomas; Kreiner, Gerhard; Kaider, Alexandra; Bergler-Klein, Jutta; Khorsand, Aliasghar; Nikfardjam, Mariam; Laufer, Günther; Maurer, Gerald; Gyöngyösi, Mariann
2014-01-01
Objectives Cost-effectiveness of percutaneous coronary intervention (PCI) using drug-eluting stents (DES), and coronary artery bypass surgery (CABG) was analyzed in patients with multivessel coronary artery disease over a 5-year follow-up. Background DES implantation reducing revascularization rate and associated costs might be attractive for health economics as compared to CABG. Methods Consecutive patients with multivessel DES-PCI (n = 114, 3.3 ± 1.2 DES/patient) or CABG (n = 85, 2.7 ± 0.9 grafts/patient) were included prospectively. Primary endpoint was cost-benefit of multivessel DES-PCI over CABG, and the incremental cost-effectiveness ratio (ICER) was calculated. Secondary endpoint was the incidence of major adverse cardiac and cerebrovascular events (MACCE), including acute myocardial infarction (AMI), all-cause death, revascularization, and stroke. Results Despite multiple uses for DES, in-hospital costs were significantly less for PCI than CABG, with 4551 €/patient difference between the groups. At 5-years, the overall costs remained higher for CABG patients (mean difference 5400 € between groups). Cost-effectiveness planes including all patients or subgroups of elderly patients, diabetic patients, or Syntax score >32 indicated that CABG is a more effective, more costly treatment mode for multivessel disease. At the 5-year follow-up, a higher incidence of MACCE (37.7% vs. 25.8%; log rank P = 0.048) and a trend towards more AMI/death/stroke (25.4% vs. 21.2%, log rank P = 0.359) was observed in PCI as compared to CABG. ICER indicated 45615 € or 126683 € to prevent one MACCE or AMI/death/stroke if CABG is performed. Conclusions Cost-effectiveness analysis of DES-PCI vs. CABG demonstrated that CABG is the most effective, but most costly, treatment for preventing MACCE in patients with multivessel disease. © 2014 Wiley Periodicals, Inc. PMID:24403120
Jones, John Eric; Chen, Meng; Yu, Qingsong
2015-01-01
To improve their corrosion resistance and thus long-term biocompatibility, 316L stainless steel coronary artery stents were coated with trimethylsilane (TMS) plasma coatings of 20–25 nm in thickness. Both direct current (DC) and radio-frequency (RF) glow discharges were utilized for TMS plasma coatings and additional NH3/O2 plasma treatment to tailor the surface properties. X-ray photoelectron spectroscopy (XPS) was used to characterize the coating surface chemistry. It was found that both DC and RF TMS plasma coatings had Si- and C-rich composition, and the O-and N-contents on the surfaces were substantially increased after NH3/O2 plasma treatment. Surface contact angle measurements showed that DC TMS plasma nanocoating with NH3/O2 plasma treatment generated very hydrophilic surface. The corrosion resistance of TMS plasma coated stents was evaluated through potentiodynamic polarization and electro-chemical impedance spectroscopy (EIS) techniques. The potentiodynamic polarization demonstrated that the TMS plasma coated stents imparted higher corrosion potential and pitting potential, as well as lower corrosion current densities as compared with uncoated controls. The surface morphology of stents before and after potentiodynamic polarization testing was analyzed with scanning electron microscopy, which indicated less corrosion on coated stents than uncoated controls. It was also noted that, from EIS data, the hydrophobic TMS plasma nanocoatings showed stable impedance modulus at 0.1 Hz after 21 day immersion in an electrolyte solution. These results suggest improved corrosion resistance of the 316L stainless steel stents by TMS plasma nanocoatings and great promise in reducing and blocking metallic ions releasing into the bloodstream. PMID:24500866
van Domburg, Ron T; Daemen, Joost; Morice, Marie-Claude; de Bruyne, Bernard; Colombo, Antonio; Macaya, Carlos; Richardt, Gert; Fajadet, Jean; Hamm, Christian; van Es, Gerrit-Anne; Wittebols, Kristel; Macours, Nathalie; Stoll, Hans Peter; Serruys, Patrick W
2010-04-01
Assessment of health related quality-of-life (HRQL) has become increasingly important as not only the clinician's view of the technical success, but also the patient's perception is being measured. We evaluated the HRQL following sirolimus-eluting coronary stent (SES) (CYPHER(R); Cordis, Johnson & Johnson, Warren, NJ, USA) implantation in patients with multivessel disease, comparing the outcomes with the historical surgical and bare metal stent (BMS) arms of the ARTS-I study. The HRQL outcomes were compared to the outcome of the historical cohorts of the randomised ARTS-I trial using the same inclusion and exclusion criteria. HRQL was evaluated at baseline, at one month and at 6, 12 and 36 months after revascularisation using the SF-36 in patients treated with SES (n=585), BMS (n=483) or coronary artery bypass graft (CABG) (n=492). The HRQL compliance rates varied from 100% at baseline to 92% at 36 months. Both stenting and CABG resulted in significant improvement of HRQL and anginal status. There was a trend towards better HRQL after CABG than BMS beyond six months. Already from the first month up to three years, SES patients had, on average, 10% significantly better HRQL than BMS patients on the HRQL subscales physical functioning, role physical functioning, role emotional functioning and mental health (p<0.01) and a trend towards better HRQL in the other subscales. Up to 12 months, the HRQL was better after SES than CABG and was identical thereafter. At all time points, angina was more prevalent in the BMS group than in both the SES and CABG groups, in which the incidence of angina was similar. At three years, 10% of the SES patients suffered from angina, 13% of the CABG patients and 20% of the BMS patients. Both stenting and CABG resulted in a significant improvement in HRQL and angina. Along with a substantial reduction of restenosis, HRQL after SES was significantly improved as compared with BMS, and was similar to CABG.
Gilgen, Nicole; Farah, Ahmed; Scheller, Bruno; Ohlow, Marc‐Alexander; Mangner, Norman; Weilenmann, Daniel; Wöhrle, Jochen; Jamshidi, Peiman; Leibundgut, Gregor; Möbius‐Winkler, Sven; Zweiker, Robert; Krackhardt, Florian; Butter, Christian; Bruch, Leonhard; Kaiser, Christoph; Hoffmann, Andreas; Rickenbacher, Peter; Mueller, Christian; Stephan, Frank‐Peter; Coslovsky, Michael
2018-01-01
The treatment of coronary small vessel disease (SVD) remains an unresolved issue. Drug‐eluting stents (DES) have limited efficacy due to increased rates of instent‐restenosis, mainly caused by late lumen loss. Drug‐coated balloons (DCB) are a promising technique because native vessels remain structurally unchanged. Basel Stent Kosten‐Effektivitäts Trial: Drug‐Coated Balloons vs. Drug‐Eluting Stents in Small Vessel Interventions (BASKET‐SMALL 2) is a multicenter, randomized, controlled, noninferiority trial of DCB vs DES in native SVD for clinical endpoints. Seven hundred fifty‐eight patients with de novo lesions in vessels <3 mm in diameter and an indication for percutaneous coronary intervention such as stable angina pectoris, silent ischemia, or acute coronary syndromes are randomized 1:1 to angioplasty with DCB vs implantation of a DES after successful initial balloon angioplasty. The primary endpoint is the combination of cardiac death, nonfatal myocardial infarction, and target‐vessel revascularization up to 1 year. Secondary endpoints include stent thrombosis, Bleeding Academic Research Consortium (BARC) type 3 to 5 bleeding, and long‐term outcome up to 3 years. Based on clinical endpoints after 1 year, we plan to assess the noninferiority of DCB compared to DES in patients undergoing primary percutaneous coronary intervention for SVD. Results will be available in the second half of 2018. This study will compare DCB and DES regarding long‐term safety and efficacy for the treatment of SVD in a large all‐comer population. PMID:29527709
Kang, Se Hun; Ahn, Jung-Min; Lee, Cheol Hyun; Lee, Pil Hyung; Kang, Soo-Jin; Lee, Seung-Whan; Kim, Young-Hak; Lee, Cheol Whan; Park, Seong-Wook; Park, Duk-Woo; Park, Seung-Jung
2017-07-01
Identifying predictive factors for major cardiovascular events and death in patients with unprotected left main coronary artery disease is of great clinical value for risk stratification and possible guidance for tailored preventive strategies. The Interventional Research Incorporation Society-Left MAIN Revascularization registry included 5795 patients with unprotected left main coronary artery disease (percutaneous coronary intervention, n=2850; coronary-artery bypass grafting, n=2337; medication alone, n=608). We analyzed the incidence and independent predictors of major adverse cardiac and cerebrovascular events (MACCE; a composite of death, MI, stroke, or repeat revascularization) and all-cause mortality in each treatment stratum. During follow-up (median, 4.3 years), the rates of MACCE and death were substantially higher in the medical group than in the percutaneous coronary intervention and coronary-artery bypass grafting groups ( P <0.001). In the percutaneous coronary intervention group, the 3 strongest predictors for MACCE were chronic renal failure, old age (≥65 years), and previous heart failure; those for all-cause mortality were chronic renal failure, old age, and low ejection fraction. In the coronary-artery bypass grafting group, old age, chronic renal failure, and low ejection fraction were the 3 strongest predictors of MACCE and death. In the medication group, old age, low ejection fraction, and diabetes mellitus were the 3 strongest predictors of MACCE and death. Among patients with unprotected left main coronary artery disease, the key clinical predictors for MACCE and death were generally similar regardless of index treatment. This study provides effect estimates for clinically relevant predictors of long-term clinical outcomes in real-world left main coronary artery patients, providing possible guidance for tailored preventive strategies. URL: https://clinicaltrials.gov. Unique identifier: NCT01341327. © 2017 American Heart Association, Inc.
Patient-specific 3D printing simulation to guide complex coronary intervention.
Oliveira-Santos, Manuel; Oliveira Santos, Eduardo; Marinho, Ana Vera; Leite, Luís; Guardado, Jorge; Matos, Vítor; Pego, Guilherme Mariano; Marques, João Silva
2018-05-07
The field of three-dimensional printing applied to patient-specific simulation is evolving as a tool to enhance intervention results. We report the first case of a fully simulated percutaneous coronary intervention in a three-dimensional patient-specific model to guide treatment. An 85-year-old female presented with symptomatic in-stent restenosis in the ostial circumflex and was scheduled for percutaneous coronary intervention. Considering the complexity of the anatomy, patient setting and intervention technique, we elected to replicate the coronary anatomy using a three-dimensional model. In this way, we simulated the intervention procedure beforehand in the catheterization laboratory using standard materials. The procedure was guided by optical coherence tomography, with pre-dilatation of the lesion, implantation of a single drug-eluting stent in the ostial circumflex and kissing balloon inflation to the left anterior descending artery and circumflex. Procedural steps were replicated in the real patient's treatment, with remarkable parallelism in angiographic outcome and luminal gain at intracoronary imaging. In this proof-of-concept report, we show that patient-specific simulation is feasible to guide the treatment strategy of complex coronary artery disease. It enables the surgical team to plan and practice the procedure beforehand, and possibly predict complications and gain confidence. Copyright © 2018 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.
A novel side branch protection technique in coronary stent implantation: Jailed Corsair technique.
Numasawa, Yohei; Sakakura, Kenichi; Yamamoto, Kei; Yamamoto, Shingo; Taniguchi, Yousuke; Fujita, Hideo; Momomura, Shin-Ichi
2017-06-01
Side branch occlusion, which was one of the common complications in percutaneous coronary interventions, was closely associated with cardiac death and myocardial infarction. Clinical guidelines also support the importance of preservation of physiologic blood flow in SB during PCI to bifurcation lesions. In order to avoid side branch occlusion during stent implantation, we often performed the jailed wire technique, in which a conventional guide wire was inserted to the side branch before stent implantation to the main vessel. However, the jailed wire technique could not always prevent side branch occlusion. In this case report, we described a case of 72-year-old male suffering from angina pectoris. Coronary angiography revealed the diffuse calcified stenosis in the proximal and middle of left anterior descending coronary artery, and the large diagonal branch originated from the middle of the stenosis. To prevent side branch occlusion, we performed a novel side branch protection technique by using the Corsair microcatheter (Asahi Intecc, Nagoya, Japan). In this case report, we illustrated this "Jailed Corsair technique", and discussed the advantage compared to other side branch protection techniques such as the jailed balloon technique. Copyright © 2017 Elsevier Inc. All rights reserved.
[ECG and ST-elevation myocardial infarction in multivessel coronary disease].
Slavich, Gianaugusto; Spedicato, Leonardo; Poli, Stefano; Sappa, Roberta; Piccoli, Gianluca
2010-12-01
Percutaneous coronary intervention is the first-line treatment for ST-elevation myocardial infarction. In the setting of multivessel disease, concomitant reperfusion of all obstructed vessels is controversial, notably when the culprit vessel cannot be easily identified. We describe two cases with acute inferior-posterior myocardial infarction (ST-segment elevation in the inferior leads and ST-segment depression in the precordial leads). In the first case, angiography revealed severe three-vessel disease and the culprit vessel could not be identified. Following standard pharmacological therapy, the clinical picture and the ECG pattern improved, so that coronary revascularization was postponed. In the second case, angiography showed two-vessel disease with total occlusion of the right coronary and left circumflex arteries, which was treated with coronary angioplasty and drug-eluting stent implantation on the right coronary artery. In patients who undergo coronary angioplasty immediately, careful reading of the ECG can be a reliable tool for the identification of the culprit vessel in ST-elevation myocardial infarction associated with multivessel disease, allowing to choose the appropriate reperfusion strategy.
Drug-eluting stent in malignant biliary obstruction
NASA Astrophysics Data System (ADS)
Lee, Dong-Ki; Jang, Sung Ill
2012-10-01
Endoscopic stent insertion is the treatment of choice for patients with malignant biliary obstruction. However, conventional stents enable only mechanical palliation of the obstruction, without any anti-tumor effects. Drugeluting stent (DES), which was first introduced in coronary artery disease, are currently under investigation for sustaining stent patency and prolonging patient survival by inhibiting tumor ingrowth in malignant biliary obstruction. Many factors affecting efficient drug delivery have been studied to determine how drugs with antitumor effects suppress tumor ingrowth, including the specific drugs incorporated, means of incorporating the drugs, mode of drug release, and stent structure. Advances have resulted in the construction of more effective non-vascular DES and ongoing clinical research. Non-vascular DES is expected to play a vital role in prolonging the survival of patients with malignant biliary obstruction.
Magnetizable stent-grafts enable endothelial cell capture
NASA Astrophysics Data System (ADS)
Tefft, Brandon J.; Uthamaraj, Susheil; Harburn, J. Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S.
2017-04-01
Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.
Magnetizable stent-grafts enable endothelial cell capture.
Tefft, Brandon J; Uthamaraj, Susheil; Harburn, J Jonathan; Hlinomaz, Ota; Lerman, Amir; Dragomir-Daescu, Dan; Sandhu, Gurpreet S
2017-04-01
Emerging nanotechnologies have enabled the use of magnetic forces to guide the movement of magnetically-labeled cells, drugs, and other therapeutic agents. Endothelial cells labeled with superparamagnetic iron oxide nanoparticles (SPION) have previously been captured on the surface of magnetizable 2205 duplex stainless steel stents in a porcine coronary implantation model. Recently, we have coated these stents with electrospun polyurethane nanofibers to fabricate prototype stent-grafts. Facilitated endothelialization may help improve the healing of arteries treated with stent-grafts, reduce the risk of thrombosis and restenosis, and enable small-caliber applications. When placed in a SPION-labeled endothelial cell suspension in the presence of an external magnetic field, magnetized stent-grafts successfully captured cells to the surface regions adjacent to the stent struts. Implantation within the coronary circulation of pigs (n=13) followed immediately by SPION-labeled autologous endothelial cell delivery resulted in widely patent devices with a thin, uniform neointima and no signs of thrombosis or inflammation at 7 days. Furthermore, the magnetized stent-grafts successfully captured and retained SPION-labeled endothelial cells to select regions adjacent to stent struts and between stent struts, whereas the non-magnetized control stent-grafts did not. Early results with these prototype devices are encouraging and further refinements will be necessary in order to achieve more uniform cell capture and complete endothelialization. Once optimized, this approach may lead to more rapid and complete healing of vascular stent-grafts with a concomitant improvement in long-term device performance.
Kosmidou, Ioanna; McAndrew, Thomas; Redfors, Björn; Embacher, Monica; Dizon, José M; Mehran, Roxana; Ben-Yehuda, Ori; Mintz, Gary S; Stone, Gregg W
2017-07-19
Bradycardia on presentation is frequently observed in patients with right coronary artery ST-segment elevation myocardial infarction, but it is largely unknown whether it predicts poor angiographic or clinical outcomes in that patient population. We sought to determine the prognostic implications of admission heart rate (AHR) in patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion. We analyzed 1460 patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion enrolled in the randomized HORIZONS-AMI (Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction) trial who underwent primary percutaneous coronary intervention. Patients presenting with high-grade atrioventricular block were excluded. Outcomes were examined according to AHR range (AHR <60, 61-79, 80-99, and ≥100 beats per minute). Baseline and procedural characteristics did not vary significantly with AHR except for a more frequent history of diabetes mellitus, longer symptom-to-balloon time, more frequent cardiogenic shock, and less frequent restoration of thrombolysis in myocardial infarction 3 flow in patients with admission tachycardia (AHR >100 beats per minute). Angiographic analysis showed no significant association between AHR and lesion location or complexity. On multivariate analysis, admission bradycardia (AHR <60 beats per minute) was not associated with increased 1-year mortality (hazard ratio 1.33; 95% CI 0.41-4.34, P =0.64) or major adverse cardiac events (hazard ratio 1.08; 95% CI 0.62-1.88, P =0.78), whereas admission tachycardia was a strong independent predictor of mortality (hazard ratio 5.02; 95% CI 1.95-12.88, P =0.0008) and major adverse cardiac events (hazard ratio 2.20; 95% CI 1.29-3.75, P =0.0004). In patients with ST-segment elevation myocardial infarction and a right coronary artery culprit lesion undergoing primary percutaneous coronary intervention, admission bradycardia was not associated with increased mortality or major adverse cardiac events at 1 year. URL: https://www.clinicaltrials.gov. Unique identifier: NCT00433966. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Pandya, Sanjay B; Kim, Young-Hak; Meyers, Sheridan N; Davidson, Charles J; Flaherty, James D; Park, Duk-Woo; Mediratta, Anuj; Pieper, Karen; Reyes, Eric; Bonow, Robert O; Park, Seung-Jung; Beohar, Nirat
2010-06-01
We undertook a meta-analysis to assess outcomes for drug-eluting stents (DES) and bare-metal stents (BMS) in percutaneous coronary intervention for unprotected left main coronary artery (ULMCA) stenosis. Uncertainty exists regarding the relative performance of DES versus BMS in percutaneous coronary intervention for unprotected left main coronary stenosis. Of a total of 838 studies, 44 met inclusion criteria (n = 10,342). The co-primary end points were mortality, myocardial infarction (MI), target vessel/lesion revascularization (TVR/TLR), and major adverse cardiac events (MACE: mortality, MI, TVR/TLR). Event rates for DES and BMS were calculated at 6 to 12 months, at 2 years, and at 3 years. Crude event rates at 3 years were mortality (8.8% and 12.7%), MI (4.0% and 3.4%), TVR/TLR (8.0% and 16.4%), and MACE (21.4% and 31.6%). Nine studies were included in a comparative analysis (n = 5,081). At 6 to 12 months the adjusted odds ratio (OR) for DES versus BMS were: mortality 0.94 (95% confidence interval [CI]: 0.06 to 15.48; p = 0.97), MI 0.64 (95% CI: 0.19 to 2.17; p = 0.47), TVR/TLR 0.10 (95% CI: 0.01 to 0.84; p = 0.01), and MACE 0.34 (95% CI: 0.15 to 0.78; p = 0.01). At 2 years, the OR for DES versus BMS were: mortality 0.42 (95% CI: 0.28 to 0.62; p < 0.01), MI 0.16 (95% CI: 0.01 to 3.53; p = 0.13), and MACE 0.31 (95% CI: 0.15 to 0.66; p < 0.01). At 3 years, the OR for DES versus BMS were: mortality 0.70 (95% CI: 0.53 to 0.92; p = 0.01), MI 0.49 (95% CI: 0.26 to 0.92; p = 0.03), TVR/TLR 0.46 (95% CI: 0.30 to 0.69; p < 0.01), and MACE 0.78 (95% CI: 0.57 to 1.07; p = 0.12). Our meta-analysis suggests that DES is associated with favorable outcomes for mortality, MI, TVR/TLR, and MACE as compared to BMS in percutaneous coronary intervention for unprotected left main coronary artery stenosis. Copyright 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Onset of recent exertional dyspnoea in a firefighter with left bundle-branch block
De Rosa, Roberto; Ratti, Gennaro; Lamberti, Monica
2014-01-01
Background The presence of a left bundle-branch block (LBBB) among firefighters raises questions about stratifying risk of subsequent cardiovascular events as this conduction disorder may mask underlying coronary artery disease. This report describes the case of a firefighter with a history LBBB with exertional dyspnoea of recent onset after work activity. Case report A 39-year-old male firefighter with LBBB developed exertional dyspnoea after a prolonged session of work. ECG and treadmill test only showed a permanent LBBB; echocardiography and myocardial scintigraphy did not add to this. However, multislice CT (MSCT) showed a significant stenosis in the mid-left anterior descending artery (LAD). Coronary angiography confirmed the stenosis with subsequent placement of a coronary stent. Conclusions An occupational physician should take into account that factors such as age and low cardiovascular risk do not always exclude heart disease, especially when there are conduction system abnormalities that can mask possible coronary artery disease. PMID:25352387
Onset of recent exertional dyspnoea in a firefighter with left bundle-branch block.
De Rosa, Roberto; Ratti, Gennaro; Lamberti, Monica
2014-10-28
The presence of a left bundle-branch block (LBBB) among firefighters raises questions about stratifying risk of subsequent cardiovascular events as this conduction disorder may mask underlying coronary artery disease. This report describes the case of a firefighter with a history LBBB with exertional dyspnoea of recent onset after work activity. A 39-year-old male firefighter with LBBB developed exertional dyspnoea after a prolonged session of work. ECG and treadmill test only showed a permanent LBBB; echocardiography and myocardial scintigraphy did not add to this. However, multislice CT (MSCT) showed a significant stenosis in the mid-left anterior descending artery (LAD). Coronary angiography confirmed the stenosis with subsequent placement of a coronary stent. An occupational physician should take into account that factors such as age and low cardiovascular risk do not always exclude heart disease, especially when there are conduction system abnormalities that can mask possible coronary artery disease. 2014 BMJ Publishing Group Ltd.
Unprotected Left Main Disease: Indications and Optimal Strategies for Percutaneous Intervention.
Li, Jun; Patel, Sandeep M; Parikh, Manish A; Parikh, Sahil A
2016-03-01
Although the incidence of left main (LM) coronary artery disease is relatively low in patients undergoing routine angiography, it is a common presentation in patients with acute coronary syndromes. With the current interventional tools and techniques, percutaneous intervention for LM disease has become a viable alternative to the traditional coronary artery bypass grafting. Factors that contribute to the success and appropriateness of percutaneous intervention for LM disease include coronary anatomy and patient-specific factors such as left ventricular function. Multiple considerations should be taken into account prior to intervention, including hemodynamic support if necessary, intravascular imaging to guide therapy, and stent technique. This review provides an overview of the current body of literature to support the use of percutaneous intervention in LM disease and serves as guideline for the interventionalist approaching LM revascularization.
General thoracic surgery is safe in patients taking clopidogrel (Plavix).
Cerfolio, Robert James; Minnich, Douglas J; Bryant, Ayesha S
2010-11-01
The objective of this study was to assess the safety of general thoracic surgery in patients taking antiplatelet (clopidogrel) therapy. A prospective study was conducted of consecutive patients who underwent general thoracic surgery and who were taking clopidogrel perioperatively. They were matched using a propensity score from our prospective database of 11,768 patients. Intraoperative and postoperative outcomes were compared. Between January 2009 and April 2010 there were 33 patients on clopidogrel at the time of surgery and 132 controls. The most common procedures were thoracotomy with lobectomy in 11 patients (robotic in 1), video-assisted wedge resection in 6, mediastinoscopy in 4, and Ivor Lewis esophagogastrectomy in 2. Epidurals were not used. There was no intraoperative morbidity or bleeding in primary thoracotomy; however, 2 of the 4 patients who underwent redo thoracotomy had bleeding that required transfusions. None of the 8 patients receiving clopidogrel who had a coronary artery stent and underwent lobectomy had a perioperative myocardial infarction whereas 5 of the 14 control patients undergoing lobectomy who had a coronary artery stent did (P = .05). Otherwise, morbidity, mortality, and length of stay were no different. Patients who are receiving clopidogrel and who have a coronary artery stent placed can safely undergo general thoracic surgery. The widely held belief that surgery cannot be performed without bleeding is untrue. This new finding not only eliminates much of the preoperative dilemma posed by these patients but also may reduce their risk of a postoperative myocardial infarction. However, patients who require a redo thoracotomy may be at increased risk of bleeding. Copyright © 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.
Medical therapy v. PCI in stable coronary artery disease: a cost-effectiveness analysis.
Wijeysundera, Harindra C; Tomlinson, George; Ko, Dennis T; Dzavik, Vladimir; Krahn, Murray D
2013-10-01
Percutaneous coronary intervention (PCI) with either drug-eluting stents (DES) or bare metal stents (BMS) reduces angina and repeat procedures compared with optimal medical therapy alone. It remains unclear if these benefits are sufficient to offset their increased costs and small increase in adverse events. Cost utility analysis of initial medical therapy v. PCI with either BMS or DES. . Markov cohort decision model. Data Sources. Propensity-matched observational data from Ontario, Canada, for baseline event rates. Effectiveness and utility data obtained from the published literature, with costs from the Ontario Case Costing Initiative. Patients with stable coronary artery disease, confirmed after angiography, stratified by risk of restenosis based on diabetic status, lesion size, and lesion length. Time Horizon. Lifetime. Perspective. Ontario Ministry of Health and Long Term Care. Interventions. Optimal medical therapy, PCI with BMS or DES. Lifetime costs, quality-adjusted life years (QALYs), and the incremental cost-effectiveness ratio (ICER). of Base Case Analysis. In the overall population, medical therapy had the lowest lifetime costs at $22,952 v. $25,081 and $25,536 for BMS and DES, respectively. Medical therapy had a quality-adjusted life expectancy of 10.1 v. 10.26 QALYs for BMS, producing an ICER of $13,271/QALY. The DES strategy had a quality-adjusted life expectancy of only 10.20 QALYs and was dominated by the BMS strategy. This ranking was consistent in all groups stratified by restenosis risk, except diabetic patients with long lesions in small arteries, in whom DES was cost-effective compared with medical therapy (ICER of $18,826/QALY). Limitations. There is the possibility of residual unobserved confounding. In patients with stable coronary artery disease, an initial BMS strategy is cost-effective.
Exertional headache and coronary ischemia despite normal electrocardiographic stress testing.
Cutrer, F Michael; Huerter, Karina
2006-01-01
Exertional headaches may under certain conditions reflect coronary ischemia. We report the case of a patient seen in a neurology referral practice whose exertional headaches, even in the face of two normal electrocardiographic stress tests and in the absence of underlying chest pain were the sole symptoms of coronary ischemia as detected by Tc-99m Sestamibi testing SPECT stress testing. Stent placement resulted in complete resolution of headaches. Exertional headache in the absence of chest pain may reflect underlying symptomatic coronary artery disease (CAD) even when conventional electrocardiographic stress testing does not indicate ischemia.
Iijima, Raisuke; Kougame, Norihiro; Hara, Hidehiko; Moroi, Masao; Nakamura, Masato
2018-06-12
The aim of this study was to investigate whether drug-coated balloon (DCB) treatment is effective for de novo coronary lesions that are unsuitable for drug-eluting stent (DES) implantation.Methods and Results:This retrospective study included 118 de novo lesions that were not suitable for DES implantation. Of the lesions, 40% was treated because of very small vessel disease. Patients with planned non-cardiac surgery and at high bleeding risk were 3% and 19%, respectively, and lesions that easily develop stent fracture comprised 26%. Clinically driven target lesion revascularization (TLR) was the primary endpoint. The rate of suboptimal lesion preparation before DCB treatment was set as the secondary endpoint. Optimal lesion preparation was defined as acquisition of Thrombolysis in Myocardial Infarction flow grade 3, minor coronary dissection, and residual stenosis ≤30%. The rate of suboptimal lesion preparation was 2.5% and 3 patients needed bail-out stenting. Accordingly, 115 patients were treated with a DCB. Clinically driven TLR had occurred in 8 patients (7.0%) at the 8-month follow-up. The presence of chronic total occlusion was identified as an independent predictor for TLR (odds 11.57; 95% confidence interval, 1.38-135.54; P=0.02). For lesions that are unsuitable for stent implantation, stent-less intervention using a DCB should be considered initially. The present study also highlighted that lesion preparation is key to a successful DCB strategy.
Insights into coronary collateral formation from a novel porcine semiacute infarction model.
Krackhardt, Florian; Harnoss, Jonathan M; Waliszewski, Matthias W; Ritter, Zully; Granzow, Susanne; Felsenberg, Dieter; Neumann, Konrad; Lerman, Lilian O; Hillmeister, Philipp; Gebker, Rolf; Paetsch, Ingo; Riediger, Fabian; Bramlage, Peter; Buschmann, Ivo R
2018-03-01
For patients with severe ischemic heart disease, complete revascularization by a percutaneous coronary intervention or coronary artery bypass grafting is often not achieved and may still cause residual angina. In case of progressive coronary artery occlusions, therapeutic arteriogenesis constitutes a promising strategy for increasing blood supply to the ischemic myocardium. Whether the formation of collaterals in the hypofused myocardium is angiogenetic in nature or based on preformed coronary artery anastomoses remains debatable. The objectives of this research were (i) the development of an appropriate research methodology to study a humanoid animal semiacute infarction model with low mortality and (ii) to answer the question of whether collateral revascularization follows a pre-existing 'blueprint'. A porcine model was chosen in which a step-wise vessel occlusion was performed by implantation of a copper stent into the distal left anterior descending artery. Vessel occlusion and collateral development were confirmed in vivo every 14 days up to day 56 by repeated coronary angiography and myocardial perfusion measurement using cardiac MRI. After the completion of the in-vivo imaging studies, animals were euthanized and collateral growth was evaluated using microcomputer tomography. Our porcine model of semiacute noninvasive coronary artery occlusion confirmed the existence of preformed coronary anastomoses and the proliferation of functional vessels in hypoperfused myocardium. Repetitive intra-animal MRIs showed the functional impact of these growing collaterals. The confirmation of preformed coronary anastomoses during the process of collateralization (natural bypasses) offers a preclinical avenue to carry out arteriogenetic pharmaceutical research in patients with ischemic heart disease.
Treitl, Karla Maria; Woerner, Benedikt; Schinner, Regina; Czihal, Michael; Notohamiprodjo, Susan; Hoffmann, Ulrich; Treitl, Marcus
2017-09-01
To analyse the patency rates of femoro-popliteal stenting with different self-expandable Nitinol stent-designs. Two hundred and twenty-two patients (142 (64%) male; age 72.4 ± 11.6 years) with symptomatic femoro-popliteal peripheral arterial occlusive disease (PAOD) underwent percutaneous transluminal angioplasty (PTA) and stenting with three different Nitinol stents (interwoven IW: n = 70; closed-cell CC: n = 85; open-cell OC: n = 67). One-year post-procedural target lesion revascularization (TLR_12M) rates were investigated with regard to co-morbidities: diabetes (DBM), hyperlipidaemia (HLP), hypertension (RR), coronary artery disease (CAD) and degree of calcification. Twelve-month follow-up data were available for 60, 69 and 50 patients in the IW, OC and CC groups (179 patients in total). The cumulative patency (IW: 52 (86.7%); OC: 50 (72.5%); CC: 23 (46.0%); P < 0.001) and the TLR_12M rates (IW: 8 (13.3%); OC: 19 (27.5%); CC: 27 (54.0%); P < 0.001) differed significantly, as did the subgroup analyses (DBM: P = 0.05; RR: P = 0.003; HLP: P = 0.005; CAD: P = 0.02; localization: P < 0.001; calcification: P < 0.001), with the best patency for the IW stent and the highest TLR_12M for the CC stent. The interwoven stent-design was superior to the standard open- and closed-cell stent-designs in endovascular treatment of femoro-popliteal PAOD in a follow-up period of 12 months. • Results of femoro-popliteal stenting are still unsatisfactory. • Comparative studies for currently available different Nitinol stent-designs are lacking. • This is a first comparative study on long-term patency of different Nitinol stent-designs. • Interwoven stent-design leads to improved long-term patency. • Interwoven stent-design leads to lower TLR than other stent-designs.
Le Hello, Claire; Morello, Rémy; Lequerrec, Agnès; Duarte, Christine; Riddell, John; Hamon, Martial
2007-01-01
Aim To prospectively determine the role of platelet glycoprotein IIIa (GP IIIa) gene PlA1/PlA2 polymorphism on the long-term clinical outcome in patients with coronary artery disease undergoing coronary stenting. Design and setting Prospective observational study in the University Hospital of Caen (France). Patients and methods 1 111 symptomatic consecutive Caucasian patients treated with percutaneous coronary intervention including stent implantation underwent genotyping for GP IIIa PlA1/A2. Main outcome measures Long-term clinical outcome in terms of the rate of major adverse cardiac events (MACE, ie death from any cause, non-fatal Q wave or non Q wave myocardial infarction, and need for coronary revascularisation) was obtained and subsequently stratified according to the GP IIIa PlA1/A2 polymorphism. Results Three groups of patients were determined according to the GP IIIa PlA1/A2 polymorphism (71.6% had the A1/A1, 25.8% had the A1/A2 and 2.6% had the A2/A2 genotype). These three groups were comparable for all clinical characteristics including sex ratio, mean age, vascular risk factors, previous coronary events, baseline angiographic exam, indication for the percutaneous coronary intervention and drug therapy). The incidence of MACE was similar in these 3 groups of patients during a mean follow-up period of 654+/-152 days. Independent risk factors for MACE were a left ventricular ejection fraction < 40%, absence of treatment with a beta-blocker and absence of treatment with an angiotensin converting enzyme inhibitor during follow-up. Conclusion The GP IIIa PlA1/A2 polymorphism does not influence the clinical long-term outcome in patients with symptomatic coronary disease undergoing percutaneous coronary intervention with stent implantation. PMID:18021403
Suh, Soon Yong; Kang, Woong Chol; Oh, Pyung Chun; Choi, Hanul; Moon, Chan Il; Lee, Kyounghoon; Han, Seung Hwan; Ahn, Taehoon; Choi, In Suck; Shin, Eak Kyun
2014-09-01
There are limited data on the optimal antithrombotic therapy for patients with atrial fibrillation (AF) who undergoing coronary stenting. We reviewed 203 patients (62.6 % men, mean age 68.3 ± 10.1 years) between 2003 and 2012, and recorded clinical and demographic characteristics of the patients. Clinical follow-up included major adverse cardiac and cerebrovascular events (MACCE) (cardiac death, myocardial infarction, target lesion revascularization, and stroke), stent thrombosis, and bleeding. The most commonly associated comorbidities were hypertension (70.4 %), diabetes mellitus (35.5 %), and congestive heart failure (26.6 %). Sixty-three percent of patients had stroke risk higher than CHADS2 score 2. At discharge, dual-antiplatelet therapy (aspirin, clopidogrel) was used in 166 patients (81.8 %; Group I), whereas 37 patients (18.2 %) were discharged with triple therapy (aspirin, clopidogrel, warfarin; Group II). The mean follow-up period was 42.0 ± 29.0 months. The mean international normalized ratio (INR) in group II was 1.83 ± 0.41. The total MACCE was 16.3 %, with stroke in 3.4 %. Compared with the group II, the incidence of MACCE (2.7 % vs 19.3 %, P = 0.012) and cardiac death (0 % vs 11.4 %, P = 0.028) were higher in the group I. Major and any bleeding, however, did not differ between the two groups. In multivariate analysis, no warfarin therapy (odds ratio 7.8, 95 % confidence interval 1.02-59.35; P = 0.048) was an independent predictor of MACCE. By Kaplan-Meier survival analysis, warfarin therapy was associated with a lower risk of MACCE (P = 0.024). In patients with AF undergoing coronary artery stenting, MACCE were reduced by warfarin therapy without increased bleeding, which might be related to tighter control with a lower INR value.
Two-year safety and effectiveness of sirolimus-eluting stents (from a prospective registry).
Claessen, Bimmer E; Mehran, Roxana; Leon, Martin B; Heller, Eric A; Weisz, Giora; Syros, George; Mintz, Gary S; Franklin-Bond, Theresa; Apostolidou, Irene; Henriques, Jose P S; Stone, Gregg W; Moses, Jeffrey W; Dangas, George D
2011-02-15
Uncertainty exists about the long-term safety and efficacy outcomes of sirolimus-eluting stents (SESs) in unselected patients. The present study was performed to evaluate the safety and efficacy of the SES in treatment of patients with coronary artery disease in an unselected population. Over a 2-year period, 1,504 consecutive patients undergoing percutaneous coronary intervention with ≥1 SES were enrolled. The primary end point was the occurrence of target vessel failure (TVF; a composite of cardiac death, myocardial infarction, or clinically driven target vessel revascularization). An independent clinical event committee adjudicated all adverse events up to 2-year follow-up. Dual antiplatelet therapy was recommended for ≥1 year throughout the study period. Mean age was 65 ± 11 years; 75% were men, and 34% were diabetics. SESs were implanted for off-label indications in 86% of cases. TVF rates were 3.3%, 6.9%, 11.5%, and 15.5% at 30-day, 6-month, 1-year, and 2-year follow-ups, respectively. The 2-year cumulative rate of definite/probable stent thrombosis was 0.9%; 0.2% was very late thrombosis, occurring from 1 year to 2 years. Patients off dual antiplatelet therapy at 6 months had a significantly increased rate of subsequent death from noncardiac causes. Patients off dual antiplatelet therapy at 1 year had a significantly decreased rate of subsequent clinically driven target lesion revascularization. In conclusion, use of SESs in unselected patients with coronary artery disease was associated with a low TVF rate at 2 years with an acceptable incidence of stent thrombosis. Copyright © 2011 Elsevier Inc. All rights reserved.
Rigatelli, Gianluca; Avvocata, Fabio Dell'; Ronco, Federico; Giordan, Massimo; Roncon, Loris; Caprioglio, Francesco; Grassi, Giuseppe; Faggian, Giuseppe; Cardaioli, Paolo
2016-06-01
Implantation of Drug Eluting Stents (DES) plus bioresorbable scaffolds (BVS) in very long diffuse left anterior descending coronary artery (LAD) disease may be problematic because of multiple devices overlapping. We sought to assess the short and mid-tern outcomes of combined implantation of DES and BVS using a novel "edge-to-edge" technique in patients with diffuse LAD disease. Patients with long diffuse LAD disease were enrolled in a prospective registry from 1st August 2014 to 1st August 2015 and treated with IVUS-aided percutaneous coronary intervention using a DES plus a single or multiple BVS using a novel "edge-to-edge" technique. Clinical follow up and invasive follow up driven by clinical justification was performed. Twenty-three patients (5 females, mean age 59.1± 9.1 years) were enrolled. Mean length of LAD disease was 73.1 ± 20.6 mm. Mean number of DES and BVS implanted was 1.2 ± 0.4 and 1.7 ± 1.3, respectively. At a mean follow-up of 11.3 ± 3.8 months, no stent thrombosis or MACE were observed. Angiographic and IVUS follow-up at a mean of 6.6 ± 0.7 months showed no significant angiographic restenosis and no appreciable stent gaps. In revascularization of long diffuse disease of the LAD, the edge-to-edge implantation technique appears to be feasible resulting in no restenosis or thrombosis on the short-term follow-up. (J Interven Cardiol 2016;29:275-284). © 2016, Wiley Periodicals, Inc.
García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan
2015-01-01
Objective The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. Materials and Methods The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Results Of the 16 angiographic procedures, 14 (87.5s%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Conclusion Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. PMID:25531292
García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan
2015-01-01
The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Of the 16 angiographic procedures, 14 (87.5%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. © 2014 S. Karger AG, Basel.
[Instantaneous wave-free ratio (iFR®) in patients with coronary artery disease].
Baumann, S; Schaefer, A C; Hohneck, A; Mueller, K; Becher, T; Behnes, M; Renker, M; Borggrefe, M; Akin, I; Lossnitzer, D
2017-08-23
Coronary angiography is considered as the gold standard in the morphological representation of coronary artery stenosis. Coronary angiography is often performed without preprocedural non-invasive proof of ischemia and the assessment of the severity of a coronary lesion by morphology is very subjective. Thus, invasive fractional flow reserve (FFR) measurement represents the current standard for estimation of the hemodynamic relevance of coronary artery stenosis and facilitates decision making for percutaneous coronary intervention (PCI) and stenting. The FFR-guided revascularization strategy has been classified as a class IA recommendation in the 2014 ESC/EACTS guidelines on myocardial revascularization. Both the DEFER and the FAME studies showed no treatment advantage of hemodynamically irrelevant stenosis. By use of FFR (and targeted interventions), clinical results could be improved as well as the procedure costs were reduced; however, the use in clinical practice is still limited due to the need of adenosine administration and a significant prolongation of the procedure. Instantaneous wave-free ratio (iFR®) is a new innovative approach for the determination of the hemodynamic relevance of coronary stenosis which can be obtained at rest without the use of vasodilators. Regarding periprocedural complications as well as prognosis, iFR® showed non-inferiority compared to FFR in the SWEDEHEART and DEFINE-FLAIR trials.
Polymeric coating of surface modified nitinol stent with POSS-nanocomposite polymer.
Bakhshi, Raheleh; Darbyshire, Arnold; Evans, James Eaton; You, Zhong; Lu, Jian; Seifalian, Alexander M
2011-08-01
Stent angioplasty is a successful treatment for arterial occlusion, particularly in coronary artery disease. The clinical communities were enthusiastic about the use of drug-eluting stents; however, these stents have a tendency to be a contributory factor towards late stage thrombosis, leading to mortality in a significant number of patients per year. This work presents an innovative approach in self-expanding coronary stents preparation. We developed a new nanocomposite polymer based on polyhedral oligomeric silsesquioxanes (POSS) and poly(carbonate-urea)urethane (PCU), which is an antithrombogenic and a non-biodegradable polymer with in situ endothelialization properties. The aim of this work is to coat a NiTi stent alloy with POSS-PCU. In prolonged applications in the human body, the corrosion of the NiTi alloy can result in the release of deleterious ions which leads to unwanted biological reactions. Coating the nitinol (NiTi) surface with POSS-PCU can enhance surface resistance and improve biocompatibility. Electrohydrodynamic spraying was used as the polymer deposition process and thus a few experiments were carried out to compare this process with casting. Prior to deposition the NiTi has been surface modified. The peel strength of the deposit was studied before and after degradation of the coating. It is shown that the surface modification enhances the peel strength by 300%. It is also indicated how the adhesion strength of the POSS-PCU coating changes post-exposure to physiological solutions comprised of hydrolytic, oxidative, peroxidative and biological media. This part of the study shows that the modified NiTi presents far greater resistance to decay in peel strength compared to the non-modified NiTi. Copyright © 2011 Elsevier B.V. All rights reserved.
Wang, John C; Carrié, Didier; Masotti, Monica; Erglis, Andrejs; Mego, David; Watkins, Matthew W; Underwood, Paul; Allocco, Dominic J; Hamm, Christian W
2015-03-01
Bare metal stents (BMS) have similar rates of death and myocardial infarction (MI) compared to drug-eluting stents (DES). DES lower repeat revascularization rates compared to BMS, but may have higher rates of late stent thrombosis (ST) potentially due to impaired endothelialization requiring longer dual anti-platelet therapy (DAPT). OMEGA evaluated a novel BMS designed to have improved deliverability and radiopacity, in comparison to currently available platforms. OMEGA was a prospective, multicenter, single-arm study enrolling 328 patients at 37 sites (US and Europe). Patients received the OMEGA stent (bare platinum chromium element stent) for the treatment of de novo native coronary artery lesions (≤28 mm long; diameter ≥2.25 mm to ≤4.50mm). The primary endpoint was 9-month target lesion failure (TLF: cardiac death, target vessel-related MI, target lesion revascularization [TLR]) compared to a prespecified performance goal (PG) based on prior generation BMS. All major cardiac events were independently adjudicated. DAPT was required for a minimum of 1 month post procedure. In the OMEGA study, the mean age was 65; 17% had diabetes mellitus. The primary endpoint was met; 9 month TLF rate was 11.5%, and the upper 1-sided 95% confidence bound of 14.79% was less than the prespecified PG of 21.2% (p<0.0001). One-year event rates were low including a TLF rate of 12.8% and an ST rate of 0.6% at 12 months. One-year outcomes of OMEGA show low rates of TLF, revascularization and ST. This supports safety and efficacy of the OMEGA BMS for the treatment of coronary artery disease. Copyright © 2015 Elsevier Inc. All rights reserved.
Teng, Monica; Zhao, Ying Jiao; Khoo, Ai Leng; Ananthakrishna, Rajiv; Yeo, Tiong Cheng; Lim, Boon Peng; Chan, Mark Y; Loh, Joshua P
2018-06-05
Compared with second-generation durable polymer drug-eluting stents (DP-DES), the cost-effectiveness of biodegradable polymer drug-eluting stents (BP-DES) remains unclear in the real-world setting. We assessed the cost-effectiveness of BP-DES in patients with coronary artery disease undergoing percutaneous coronary intervention (PCI). We developed a decision-analytic model to compare the cost-effectiveness of BP-DES to DP-DES over one year and five years from healthcare payer perspective. Relative treatment effects during the first year post-PCI were obtained from a real-world population analysis while clinical event risks in the subsequent four years were derived from a meta-analysis of published studies. At one year, based on the clinical data analysis of 497 propensity-score matched pairs of patients, BP-DES were associated with an incremental cost-effectiveness ratio (ICER) of USD20,503 per quality-adjusted life-year (QALY) gained. At five years, BP-DES yielded an ICER of USD4,062 per QALY gained. At the willingness-to-pay threshold of USD50,400 (one gross domestic product per capita in Singapore in 2015), BP-DES were cost-effective. Sensitivity analysis showed that the cost of stents had a significant impact on the cost-effectiveness of BP-DES. Threshold analysis demonstrated that if the cost difference between BP-DES and DP-DES exceeded USD493, BP-DES would not be cost-effective in patients with one-year of follow-up. BP-DES were cost-effective compared with DP-DES in patients with coronary artery disease at one year and five years after PCI. It is worth noting that the cost of stents had a significant impact on the findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Baron, Suzanne J; Chinnakondepalli, Khaja; Magnuson, Elizabeth A; Kandzari, David E; Puskas, John D; Ben-Yehuda, Ori; van Es, Gerrit-Anne; Taggart, David P; Morice, Marie-Claude; Lembo, Nicholas J; Brown, W Morris; Banning, Adrian; Simonton, Charles A; Kappetein, A Pieter; Sabik, Joseph F; Serruys, Patrick W; Stone, Gregg W; Cohen, David J
2017-12-26
The EXCEL (Evaluation of Xience Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization) trial compared outcomes in patients with unprotected left main coronary artery disease (LMCAD) treated with coronary artery bypass graft (CABG) or percutaneous coronary intervention (PCI) using everolimus-eluting stents. Whereas rates of death, stroke, and myocardial infarction were similar at 36 months, event timing and repeat revascularization rates differed by treatment group. To understand the effects of revascularization strategy from the patient's perspective, a prospective quality of life (QoL) substudy was performed alongside the EXCEL trial. Between September 2010 and March 2014, 1,905 patients with LMCAD were randomized to undergo CABG or PCI, of whom 1,788 participated in the QoL substudy. QoL was assessed at baseline and 1, 12, and 36 months using the Seattle Angina Questionnaire, the 12-Item Short Form Health Survey, the Rose Dyspnea Scale, the Patient Health Questionnaire-8, and the EQ-5D. Differences between PCI and CABG were assessed using longitudinal random-effect growth curve models. Over 36 months, both PCI and CABG were associated with significant improvements in QoL compared with baseline. At 1 month, PCI was associated with better QoL than CABG. By 12 months though, these differences were largely attenuated, and by 36 months, there were no significant QoL differences between PCI and CABG. Among selected patients with LMCAD, both PCI and CABG result in similar QoL improvement through 36 months, although a greater early benefit is seen with PCI. Taken together with the 3-year clinical results of EXCEL, these findings suggest that PCI and CABG provide similar intermediate-term outcomes for patients with LMCAD. (Evaluation of Xience Versus Coronary Artery Bypass Surgery for Effectiveness of Left Main Revascularization [EXCEL]; NCT01205776). Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Lu, Huangling; Kalkman, Deborah N; Grundeken, Maik J; Tijssen, Jan G P; Wykrzykowska, Joanna J; de Winter, Robbert J; Koch, Karel T
2018-02-01
With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections using the novel Xposition delivery device as compared with the conventional delivery device. A total of 38 patients who were treated with the self-apposing STENTYS stent and with OCT assessment at our center were retrospectively analysed. Twenty patients were treated using the Xposition- and 18 using the conventional delivery device. OCT was performed according to study protocol. Frames with poor quality were excluded. A total of 12(18%) dissections were detected, 7(20%) in the Xposition delivery device group, and 5(15%) in the conventional group (p = 1). Using the Xposition delivery device 4(33%) dissections were found proximally, using the conventional delivery device 3(25%) (p = ns). Mean longitudinal dissection length was 2.07 ± 1.80mm, 8(67%) appeared as flaps, 4(33%) as cavities. Morphometric parameters were comparable in both groups. Detailed OCT assessment of stent edge dissections was possible, which revealed no large differences using the Xposition delivery device as compared with conventional delivery device, however large studies are warranted.
NASA Astrophysics Data System (ADS)
Furdella, Kenneth J.; Witte, Russell S.; Vande Geest, Jonathan P.
2017-04-01
Although the drug-eluting stent (DES) has dramatically reduced the rate of coronary restenosis, it still occurs in up to 20% of patients with a DES. Monitoring drug delivery could be one way to decrease restenosis rates. We demonstrate real-time photoacoustic imaging and spectroscopy (PAIS) using a wavelength-tunable visible laser and clinical ultrasound scanner to track cardiac drug delivery. The photoacoustic signal was initially calibrated using porcine myocardial samples soaked with a known concentration of a drug surrogate (DiI). Next, an in situ coronary artery was perfused with DiI for 20 min and imaged to monitor dye transport in the tissue. Finally, a partially DiI-coated stent was inserted into the porcine brachiocephalic trunk for imaging. The photoacoustic signal was proportional to the DiI concentration between 2.4 and 120 μg/ml, and the dye was detected over 1.5 mm from the targeted coronary vessel. Photoacoustic imaging was also able to differentiate the DiI-coated portion of the stent from the uncoated region. These results suggest that PAIS can track drug delivery to cardiac tissue and detect drugs loaded onto a stent with sub-mm precision. Future work using PAIS may help improve DES design and reduce the probability of restenosis.
Gilgen, Nicole; Farah, Ahmed; Scheller, Bruno; Ohlow, Marc-Alexander; Mangner, Norman; Weilenmann, Daniel; Wöhrle, Jochen; Jamshidi, Peiman; Leibundgut, Gregor; Möbius-Winkler, Sven; Zweiker, Robert; Krackhardt, Florian; Butter, Christian; Bruch, Leonhard; Kaiser, Christoph; Hoffmann, Andreas; Rickenbacher, Peter; Mueller, Christian; Stephan, Frank-Peter; Coslovsky, Michael; Jeger, Raban
2018-05-01
The treatment of coronary small vessel disease (SVD) remains an unresolved issue. Drug-eluting stents (DES) have limited efficacy due to increased rates of instent-restenosis, mainly caused by late lumen loss. Drug-coated balloons (DCB) are a promising technique because native vessels remain structurally unchanged. Basel Stent Kosten-Effektivitäts Trial: Drug-Coated Balloons vs. Drug-Eluting Stents in Small Vessel Interventions (BASKET-SMALL 2) is a multicenter, randomized, controlled, noninferiority trial of DCB vs DES in native SVD for clinical endpoints. Seven hundred fifty-eight patients with de novo lesions in vessels <3 mm in diameter and an indication for percutaneous coronary intervention such as stable angina pectoris, silent ischemia, or acute coronary syndromes are randomized 1:1 to angioplasty with DCB vs implantation of a DES after successful initial balloon angioplasty. The primary endpoint is the combination of cardiac death, nonfatal myocardial infarction, and target-vessel revascularization up to 1 year. Secondary endpoints include stent thrombosis, Bleeding Academic Research Consortium (BARC) type 3 to 5 bleeding, and long-term outcome up to 3 years. Based on clinical endpoints after 1 year, we plan to assess the noninferiority of DCB compared to DES in patients undergoing primary percutaneous coronary intervention for SVD. Results will be available in the second half of 2018. This study will compare DCB and DES regarding long-term safety and efficacy for the treatment of SVD in a large all-comer population. © 2018 The Authors. Clinical Cardiology published by Wiley Periodicals, Inc.
Jeger, Raban; Pfisterer, Matthias; Alber, Hannes; Eberli, Franz; Galatius, Søren; Naber, Christoph; Pedrazzini, Giovanni; Rickli, Hans; Jensen, Jan Skov; Vuilliomenet, André; Gilgen, Nicole; Kaiser, Christoph
2012-02-01
In the BAsel Stent Kosten Effektivitäts Trial PROspective Validation Examination (BASKET-PROVE), drug-eluting stents (DESs) had similar 2-year rates of death and myocardial infarction but lower rates of target vessel revascularization and major adverse cardiac events compared with bare-metal stents (BMSs). However, comparative clinical effects of newest-generation DES with biodegradable polymers vs second-generation DES or newest-generation BMS with biocompatible coatings, all combined with a prasugrel-based antiplatelet therapy, on 2-year outcomes are not known. In BASKET-PROVE II, 2,400 patients with de novo lesions in native vessels ≥3 mm in diameter are randomized 1:1:1 to receive a conventional DES, a DES with a biodegradable polymer, or a BMS with biocompatible coating. In addition to aspirin, stable patients with BMS will receive prasugrel for 1 month, whereas all others will receive prasugrel for 12 months. The primary end point will be combined cardiac death, nonfatal myocardial infarction, and target vessel revascularization up to 2 years. Secondary end points include stent thrombosis and major bleeding. The primary aim is to test (1) the noninferiority of a biodegradable-polymer DES to a conventional DES and (2) the superiority of both DESs to BMS. A secondary aim is to compare the outcomes with those of BASKET-PROVE regarding the effects of prasugrel-based vs clopidogrel-based antiplatelet therapy. By the end of 2010, 878 patients (37% of those planned) were enrolled. This study will test the comparative long-term safety and efficacy of newest-generation stents on the background of contemporary antiplatelet therapy in a large all-comer population undergoing large native coronary artery stenting. Copyright © 2012 Mosby, Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Girinsky, Theodore, E-mail: girinsky.theodore@orange.fr; M’Kacher, Radhia; Lessard, Nathalie
Purpose: To prospectively investigate the coronary artery status using coronary CT angiography (CCTA) in patients with Hodgkin lymphoma treated with combined modalities and mediastinal irradiation. Methods and Materials: All consecutive asymptomatic patients with Hodgkin lymphoma entered the study during follow-up, from August 2007 to May 2012. Coronary CT angiography was performed, and risk factors were recorded along with leukocyte telomere length (LTL) measurements. Results: One hundred seventy-nine patients entered the 5-year study. The median follow-up was 11.6 years (range, 2.1-40.2 years), and the median interval between treatment and the CCTA was 9.5 years (range, 0.5-40 years). Coronary artery abnormalities were demonstrated in 46 patientsmore » (26%). Coronary CT angiography abnormalities were detected in nearly 15% of the patients within the first 5 years after treatment. A significant increase (34%) occurred 10 years after treatment (P=.05). Stenoses were mostly nonostial. Severe stenoses were observed in 12 (6.7%) of the patients, entailing surgery with either angioplasty with stent placement or bypass grafting in 10 of them (5.5%). A multivariate analysis demonstrated that age at treatment, hypertension, and hypercholesterolemia, as well as radiation dose to the coronary artery origins, were prognostic factors. In the group of patients with LTL measurements, hypertension and LTL were the only independent risk factors. Conclusions: The findings suggest that CCTA can identify asymptomatic individuals at risk of acute coronary artery disease who might require either preventive or curative measures. Conventional risk factors and the radiation dose to coronary artery origins were independent prognostic factors. The prognostic value of LTL needs further investigation.« less
Laser angioplasty for cardiovascular disease
NASA Astrophysics Data System (ADS)
Okada, Masayoshi
2005-07-01
Recently, endovascular interventions such as balloon angioplasty, atherectomy and the stenting method, except for conventional surgery have been clinically employed for the patients with atheromatous plaques of the peripheral- and the coronary arteries, because the number of patients with arteriosclerosis is now increasing in the worldwide. Among these procedures, restenoses after endovascular interventions have been remarkably disclosed in 20-40 % of the patients who underwent percutaneous coronary interventions. Thus, there are still some problems in keeping long-term patency by means of endovascular techniques such as balloon angioplasty and atherectomy (1, 2). For reduction of these problems , laser angioplasty using Argon laser was applied experimentally and clinically. Based on excellent experimental studies, laser was employed for 115 patients with stenotic ,or obstructive lesions occluding more thasn 75 % of the peripheral and the coronary arteries angiographycally.
Use of orbital atherectomy in acute myocardial infarction via the transradial approach
Mowakeaa, Samer; Snyder, Branden; Kakouros, Nikolaos
2016-01-01
Severe coronary artery calcifications pose an ongoing challenge when performing percutaneous coronary interventions, resulting in an increased likelihood of procedural complications. Orbital atherectomy (OA) has emerged as a promising technology that helps improve outcomes in this complex patient population. Its safety and efficacy are yet to be demonstrated in the setting of acute myocardial infarction. We present a case of a patient with acute ST-elevation myocardial infarction (STEMI) evaluated with emergent transradial coronary angiography. The culprit lesion was a severely stenotic, heavily calcified, segment of the right coronary artery. The use of OA facilitated lesion expansion and implantation of a drug-eluting stent. Although OA should be considered as contraindicated for the management of soft-ruptured plaque, which accounts for the majority of STEMI presentations, it may be well applied to the small subset of patients with calcified nodule pathology, even in the acute setting. PMID:28180008
Patrikeev, A V; Rudman, V Ia; Maksimkin, D A; Baranovich, V Iu; Faĭbushevich, A G; Veretnik, G I; Mambetov, A V; Shugushev, Z Kh
2015-01-01
Two approaches in treatment of 131 patients with postinfarction cardiosclerosis are compared in the work. Tactics of "total" myocardial revascularization means restoration of coronary blood flow in all arteries with hemodynamically significant lesion while "selective" revascularization provides restoration of coronary blood flow only in those arteries which have a viable myocardium in their pool. It was concluded that restoration of coronary blood flow in patients after myocardial infarction permits to prevent postinfarction heart remodeling, development of heart failure thereby affecting on the prognosis. Evaluation of myocardial viability in the area of suggested surgery increases efficiency of revascularization, reduces number of implantable stents and decreases frequency of unfounded coronary interventions. Elimination of ischemia in the area of hibernation provides a rapid restoration of myocardial contractility in most of left ventricle segments with initially impaired kinetics. It was revealed that terms of contractility restoration of hibernating myocardium depend on duration of hibernation period up to revascularization.
El-Said, Howaida; Hegde, Sanjeet; Moore, John
2014-01-01
The patient was a male infant with L-transposition of great arteries (L-TGA), Ebstein's anomaly of the tricuspid valve, subvalvar aortic stenosis, ventricular septal defect (VSD), hypoplastic right ventricle, arch hypoplasia, and congenital complete heart block. He underwent a Norwood procedure, aortic arch repair, permanent pacemaker implantation, and a 3.5-mm aortopulmonary shunt at 4 days of age. At the time of his surgery, left ventricular function was in the normal range (ejection fraction [EF] = 67%). However by 3 months of age, he was noted to have developed moderate-severe biventricular dysfunction (left ventricular ejection fraction [LVEF] = 34%). Atresia of the coronary sinus with a small left superior venacava (LSVC) and a bridging vein was discovered during cardiac catheterization at this time. The coronary sinus mean pressure was 17 mm Hg, and the common atrial mean pressure was 6 mmHg. We opened the atretic coronary sinus ostium using radiofrequency ablation and stent placement. There was dramatic improvement in ventricular function observed over a 2-month period. Follow-up cardiac catheterization 5 months later revealed the stent in the coronary sinus to be widely patent with no intimal buildup, and the ventricular function was normal (LVEF = 58%). The patient had a bidirectional Glenn procedure with an uncomplicated postoperative course and is currently awaiting Fontan completion. © 2013 Wiley Periodicals, Inc.
Akif Cakar, Mehmet; Tatli, Ersun; Tokatli, Alptug; Kilic, Harun; Gunduz, Huseyin; Akdemir, Ramazan
2018-03-16
Percutaneous endovascular therapy is an accepted and preferred procedure for symptomatic subclavian artery disease. However, the technical feasibility and effectiveness of treating chronic total occlusion of the subclavian artery with this approach is uncertain. We aimed to evaluate the initial and mid-term results of endovascular therapy for patients with symptomatic chronic total occlusion of the left subclavian artery. Consecutive patients who underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery between January 2010 and February 2014 were included. Overall, 16 patients (10 male, 6 female; mean age 56 ± 13 years) underwent balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery - 6 (37.5%) had arm claudication, 8 (50.0%) had vertebrobasilar insufficiency and 2 (12.5%) had coronary steal. 18 balloon-expandable stents were implanted to 15 patients. The central luminal passage was not achieved in one patient because of the subintimal position of guidewire (procedural success rate 93.8%). There were no procedure-related complications. Mean preprocedural and postprocedural systolic blood pressure differences between the upper extremities were 37 ± 13 (range 25-60) mmHg and 11 ± 9 (range 5-38) mmHg, respectively; the improvement was statistically significant. Outpatient follow-up revealed one asymptomatic restenosis at two years. Patency rate at two years was 93.3%. Balloon angioplasty and stenting for chronic total occlusion of the left subclavian artery is safe and effective, with good acute success rate and mid-term patency. Prospective randomised studies on larger patient populations would provide more precise results.
Emergency coronary artery bypass surgery in the contemporary percutaneous coronary intervention era.
Seshadri, Niranjan; Whitlow, Patrick L; Acharya, Naveen; Houghtaling, Penny; Blackstone, Eugene H; Ellis, Stephen G
2002-10-29
Since the advent of percutaneous coronary interventions (PCIs), technological advances, adjunctive pharmacotherapy, and increasing operator experience have contributed to lowering the occurrence of major complications. However, emergency coronary artery bypass surgery (CABG) for failed PCI is still associated with important morbidity and mortality, even in the era of coronary stenting. We sought to determine the prevalence, indications, predictors, and complications of emergency CABG after PCI in the past decade. We reviewed 18 593 PCIs performed from 1992 through 2000. There was a need for emergency CABG in 113 (0.61%) cases. The major indications were extensive dissection (n=61, 54%), perforation/tamponade (n=23, 20%), and recurrent acute closure (n=23, 20%). Prevalence of emergency CABG decreased from 1.5% of PCIs in 1992 to 0.14% in 2000 (P<0.001). Independent predictors of the need for emergency CABG included the worst ACC/AHA scoring of the intervened lesion (P<0.001) and female sex (P= 0.028), whereas history of prior bypass surgery and use of stents resulted in a decreased need for emergency CABG (P<0.001 for both). In patients undergoing emergency CABG, there were 17 (15%) in-hospital deaths, 14 (12%) perioperative Q-wave myocardial infarctions, and 6 (5%) cerebrovascular accidents. The need for emergency CABG has considerably decreased over time. Risk factors include female sex and a higher ACC/AHA score of the intervened lesion. However, morbidity and mortality of emergency CABG remain high even in the new millennium.
Gulizia, Michele Massimo; Colivicchi, Furio; Abrignani, Maurizio Giuseppe; Ambrosetti, Marco; Aspromonte, Nadia; Barile, Gabriella; Caporale, Roberto; Casolo, Giancarlo; Chiuini, Emilia; Di Lenarda, Andrea; Faggiano, Pompilio; Gabrielli, Domenico; Geraci, Giovanna; La Manna, Alessio Gaetano; Maggioni, Aldo Pietro; Marchese, Alfredo; Massari, Ferdinando Maria; Mureddu, Gian Francesco; Musumeci, Giuseppe; Nardi, Federico; Panno, Antonio Vittorio; Pedretti, Roberto Franco Enrico; Piredda, Massimo; Pusineri, Enrico; Riccio, Carmine; Rossini, Roberta; di Uccio, Fortunato Scotto; Urbinati, Stefano; Varbella, Ferdinando; Zito, Giovanni Battista; De Luca, Leonardo; Cappelletti, Alberto Maria; Casu, Gavino; Di Pasquale, Giuseppe; Di Tano, Giuseppe; Domenicucci, Stefano; Francese, Giuseppina Maura; Fresco, Claudio; Gensini, Gian Franco; Rovere, Maria Teresa La; Lucà, Fabiana; Mauro, Ciro; Murrone, Adriano; Rubboli, Andrea; Russo, Maria Giovanna; Santomauro, Maurizio; Tamburino, Corrado; Tarantini, Giuseppe; Vairo, Ugo; Zuin, Guerrino; Abrignani, Maurizio Giuseppe; Ambrosetti, Marco; Amico, Antonio Francesco; Aspromonte, Nadia; Aulitto, Vincenzo; Barile, Gabriella; Calculli, Giacinto; Caldarola, Pasquale; Caporale, Roberto; Cappelletti, Alberto Maria; Carbonaro, Alessandro; Casolo, Giancarlo; Casu, Gavino; Cavallini, Claudio; Chiuini, Emilia; Colivicchi, Furio; De Luca, Leonardo; Di Lenarda, Andrea; Di Pasquale, Giuseppe; Di Tano, Giuseppe; Domenicucci, Stefano; Faggiano, Pompilio; Francese, Giuseppina Maura; Fresco, Claudio; Gabrielli, Domenico; Gensini, Gian Franco; Geraci, Giovanna; Gesualdo, Loreto; Giubilato, Simona; Gulizia, Michele Massimo; La Manna, Alessio Gaetano; La Rovere, Maria Teresa; Lucà, Fabiana; Maggioni, Aldo Pietro; Marchese, Alfredo; Massari, Ferdinando Maria; Mauro, Ciro; Menozzi, Alberto; Mureddu, Gian Francesco; Murrone, Adriano; Musumeci, Giuseppe; Nardi, Federico; Noussan, Patrizia; Panno, Antonio Vittorio; Parodi, Guido; Pedretti, Roberto Franco Enrico; Perna, Gian Piero; Piredda, Massimo; Pusineri, Enrico; Riccio, Carmine; Rossini, Roberta; Rubboli, Andrea; Russo, Maria Giovanna; Saia, F; Santomauro, Maurizio; Scherillo, Marino; Scorcu, Giampaolo; di Uccio, Fortunato Scotto; Tamburino, Corrado; Tarantini, Giuseppe; Urbinati, Stefano; Vairo, Ugo; Varbella, Ferdinando; Zito, Giovanni Battista; Zuin, Guerrino
2018-01-01
Abstract Dual antiplatelet therapy (DAPT) with aspirin and a P2Y12 receptor inhibitor is the cornerstone of pharmacologic management of patients with acute coronary syndrome (ACS) and/or those receiving coronary stents. Long-term (>1 year) DAPT may further reduce the risk of stent thrombosis after a percutaneous coronary intervention (PCI) and may decrease the occurrence of non-stent-related ischaemic events in patients with ACS. Nevertheless, compared with aspirin alone, extended use of aspirin plus a P2Y12 receptor inhibitor may increase the risk of bleeding events that have been strongly linked to adverse outcomes including recurrent ischaemia, repeat hospitalisation and death. In the past years, multiple randomised trials have been published comparing the duration of DAPT after PCI and in ACS patients, investigating either a shorter or prolonged DAPT regimen. Although the current European Society of Cardiology guidelines provide a backup to individualised treatment, it appears to be difficult to identify the ideal patient profile which could safely reduce or prolong the DAPT duration in daily clinical practice. The aim of this consensus document is to review contemporary literature on optimal DAPT duration, and to guide clinicians in tailoring antiplatelet strategies in patients undergoing PCI or presenting with ACS. PMID:29867293
CT myocardial perfusion imaging: current status and future perspectives.
Yang, Dong Hyun; Kim, Young-Hak
2017-07-01
Computed tomography myocardial perfusion (CTP) combined with coronary computed tomography angiography (CCTA) may constitute a "1-stop shop" for the noninvasive diagnosis of hemodynamically significant coronary stenosis during a single CT examination. CTP shows high diagnostic performance and provides incremental value over CCTA for the detection of hemodynamically significant coronary stenosis in patients with a high Agatston calcium score or coronary artery stents. Future studies should determine the optimal protocol and clinical value of CTP for guiding revascularization strategy and prognostication. In this article, we review the current status and future perspectives of CTP, focusing on technical considerations, clinical applications, and future research topics.
Woudstra, Pier; Kalkman, Deborah N; Beijk, Marcel A; Klomp, Margo; Damman, Peter; Koch, Karel T; Henriques, Jose P S; Baan, Jan; Vis, Marije M; Piek, Jan J; Tijssen, Jan G P; de Winter, Robbert J
2018-06-01
To assess the long-term safety and clinical efficacy of the Genous endothelial progenitor cell capturing stent (ECS) compared with the TAXUS Liberté paclitaxel-eluting stent (PES) in lesions with a high risk of restenosis. Instead of the use of cytotoxic or cytostatic drugs in drug-eluting stents, a "pro-healing" approach in ECS may overcome impeded healing response due to delayed functional endothelialization of the stent struts. In the prospective, randomized TRIAS pilot study 193 patients with coronary artery lesions carrying a high risk of restenosis were included (ECS: n = 98, PES: n = 95). The primary focus of this analysis was target vessel failure (TVF) at 5 years. Dual antiplatelet therapy was prescribed for ≥1 month after ECS and for ≥6 months after PES. At 5 years follow-up, no significant differences were found in TVF (ECS 24% vs. PES 29%, risk difference 95% confidence interval (RDCI) -17.3% to 7.4%). Between 2 and 5 years after the index procedure, low numbers of TVF were observed in ECS compared with PES (ECS 4% vs. PES 16%, RDCI -20.8% to -2.3%). There was no definite stent thrombosis in ECS compared with four patients in the PES group. This is the first randomized study providing very long-term clinical efficacy and safety of the ECS in lesions carrying a high risk of restenosis. At 5 years follow-up, TVF rates in ECS group are numerically lower compared with PES due to an increase of events between 2 and 5 years after the index procedure. © 2017 Wiley Periodicals, Inc.
Caggegi, Anna; Capodanno, Davide; Capranzano, Piera; Chisari, Alberto; Ministeri, Margherita; Mangiameli, Andrea; Ronsivalle, Giuseppe; Ricca, Giovanni; Barrano, Giombattista; Monaco, Sergio; Di Salvo, Maria Elena; Tamburino, Corrado
2011-08-01
Uncertainty surrounds the optimal revascularization strategy for patients with left main coronary artery disease presenting with acute coronary syndromes (ACSs), and adequately sized specific comparisons of percutaneous and surgical revascularization in this scenario are lacking. The aim of this study was to evaluate the incidence of 1-year major adverse cardiac events (MACEs) in patients with left main coronary artery disease and ACS treated with percutaneous coronary intervention (PCI) and drug-eluting stent implantation or coronary artery bypass grafting (CABG). A total of 583 patients were included. At 1 year, MACEs were significantly higher in patients treated with PCI (n = 222) compared to those treated with CABG (n = 361, 14.4% vs 5.3%, p <0.001), driven by a higher rate of target lesion revascularization (8.1% vs 1.7%, p = 0.001). This finding was consistent after statistical adjustment for MACEs (adjusted hazard ratio [HR] 2.7, 95% confidence interval [CI] 1.2 to 5.9, p = 0.01) and target lesion revascularization (adjusted HR 8.0, 95% CI 2.2 to 28.7, p = 0.001). No statistically significant differences between PCI and CABG were noted for death (adjusted HR 1.1, 95% CI 0.4 to 3.0, p = 0.81) and myocardial infarction (adjusted HR 4.8, 95% CI 0.3 to 68.6, p = 0.25). No interaction between clinical presentation (ST-segment elevation myocardial infarction or unstable angina/non-ST-segment elevation myocardial infarction) and treatment (PCI or CABG) was observed (p for interaction = 0.68). In conclusion, in patients with left main coronary artery disease and ACS, PCI is associated with similar safety compared to CABG but higher risk of MACEs driven by increased risk of repeat revascularization. Copyright © 2011 Elsevier Inc. All rights reserved.
Tang, Y F; Han, L; Lu, F L; Song, Z G; Lang, X L; Zou, L J; Xu, Z Y
2016-07-01
To summarize the results and methods of left subclavian artery revascularization by stented trunk fenestration for acute Stanford type A aortic dissection. Clinical data of 67 patients (54 male and 13 female, mean age of (50±10) years) underwent surgical treatment of left subclavian artery fenestration for acute Stanford A aortic dissection in Department of Cardiothoracic Surgery, Changhai Hospital, Second Military Medical College between September 2008 and December 2014 were analyzed retrospectively. The origin of the left subclavian artery was in the true lumen and no dissection existed near the artery's starting. There were 18 cases of Marfan's syndrome. Preoperative echocardiography showed moderate to severe aortic regurgitation in 10 cases, and mitral regurgitation in 3 cases. Electrocardiogram showed myocardial ischemia in 5 cases. Three patients had acute impaired renal function. All the patients received total arch replacement combined with stented elephant trunk implantation. Left subclavian artery revascularization was performed by stented trunk fenestration as follows: firstly, stented elephant trunk was implanted to completely cover the left subclavian artery, then part of stented trunk's polyester lining was removed which is located at the origin of left subclavian artery. Aortic root procedures included aortic valve replacement in 2 cases, Bentall procedure in 21 cases and aortic valve sparing in 44 cases. Three patients received mitral valve repair and 6 patients received coronary artery bypass grafting. The cardiopulmonary bypass time, cross-clamp time, and circulatory arrest time were (179±32) minutes, (112±25) minutes, and (26±10) minutes, respectively. The in-hospital mortality was 7.5% (5/67): 2 patients died of multiple organ failure, 1 patient died of acute renal failure and another 2 patients died of severe infection shock. Two patients required reexploration for root bleeding. Transient neurology dysfunction developed in 6 patients. Six patients received tracheotomy and prolonged ventilation due to pulmonary infection. All patients discharged from the hospital were followed up for 1 to 5 years. During long-term follow-up, the survival rate was 100% and 89.8% at 1 and 5 years, respectively. CT angiography was performed once per year after discharged. The left subclavian artery perfusion was good. No dissection or anastomosis leakage was identified in any case. Stroke and left limb ischemia did not develope. For acute Stanford type A aortic dissection whose origin of the left subclavian artery is in the true lumen and no dissection existed near the artery's starting, the left subclavian artery revascularization by stented trunk fenestration technique during total arch replacement combined with stented elephant trunk implantation is reliable and effective.
D'Ascenzo, Fabrizio; Iannaccone, Mario; Giordana, Francesca; Chieffo, Alaide; Connor, Stephen O; Napp, L Christian; Chandran, SujaySubash; de la Torre Hernández, José María; Chen, Shao-Liang; Varbella, Ferdinando; Omedè, Pierluigi; Taha, Salma; Meliga, Emanuele; Kawamoto, Hiroyoshi; Montefusco, Antonio; Chong, Mervyn; Garot, Philippe; Sin, Lin; Gasparetto, Valeria; Abdirashid, Mohamed; Cerrato, Enrico; Biondi-Zoccai, Giuseppe; Gaita, Fiorenzo; Escaned, Javier; Hiddick Smith, David; Lefèvre, Thierry; Colombo, Antonio; Sheiban, Imad; Moretti, Claudio
2016-05-15
There is uncertainty on which stenting approach confers the best long-term outlook for unprotected left main (ULM) bifurcation disease. This is a non-randomized, retrospective study including all consecutive patients with 50% stenosis of the left main involving at least 1 of the arteries stemming from the left main treated with drug-eluting stents (DES) in 9 European centers between 2002 and 2004. Patients were divided into two groups: those treated with provisional stentings vs. those treated with two stent strategy. The outcomes of interest were 10-year rates of target lesion revascularization (TLR), major adverse cardiac events (MACE), and their components (cardiovascular death, myocardial infarction [MI], or repeat revascularization), along with stent thrombosis (ST). A total of 285 patients were included, 178 (62.5%) in the provisional stenting group and 87 (37.5%) in the two stent group. After 10 years, no differences in TLR were found at unadjusted analysis (19% vs 25%, p>0.05) nor after propensity score matching (25% vs 28%, p>0.05). Similar rates of MACE (60% vs 66%, p>0.05), death (34% vs 43%, p>0.05), MI (9% vs 14%, p>0.05) and ST were also disclosed at propensity-based analysis. Even after 10 year follow-up, patients treated with provisional stenting on left main showed comparable rates of target lesion revascularization compared to two stent strategy. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Extended use of the GuideLiner in complex coronary interventions.
Chan, Pak Hei; Alegria-Barrero, Eduardo; Foin, Nicholas; Paulo, Manuel; Lindsay, Alistair C; Viceconte, Nicola; Di Mario, Carlo
2015-07-01
Challenging coronary anatomies including chronic total occlusions (CTO), extreme vessel tortuosity, diseased bypass grafts, and anomalous coronary arteries pose difficulties in coronary interventions. The GuideLiner is a monorail catheter originally developed to facilitate delivery of stents to target lesions in tortuous vessels. We conducted a study on the feasibility and safety of utilising this catheter in a wider array of complex coronary interventions. Consecutive patients undergoing coronary or peripheral interventions where a GuideLiner was used were recruited into this study. Patient demographics, lesion and vessel characteristics, procedural details and outcomes were prospectively entered into our database and analysed. From September 2009 to October 2011, 54 consecutive patients underwent coronary intervention in our institution using a GuideLiner; 21 out of 54 coronary applications were motivated by the need to increase support to cross CTOs, predominantly of the RCA. Anomalous or angulated take-off of the treatment vessels (31%), previously deployed proximal stents (15%), heavy proximal calcification (9%) and tortuosity (7%) accounted for the remaining reasons. One patient had successful renal denervation with the aid of a GuideLiner catheter. Procedural success was 98% in our series with no device-related periprocedural complications such as ostial dissection or myocardial necrosis. The use of a GuideLiner facilitates the approach to complex coronary interventions including chronic total occlusion and saphenous vein graft intervention by providing greater back-up support and easier engagement of coronary ostia.
Shrinking the Supply Chain for Implantable Coronary Stent Devices.
Moore, Sean S; O'Sullivan, Kevin J; Verdecchia, Francesco
2016-02-01
Stenting treatments for the management of disease in the heart, arterial and venous systems, biliary ducts, urethras, ureters, oesophageal tract and prostate have made enormous technical advances since their introduction into clinical use. The progression from metallic to polymer based bio-absorbable stents, coupled with the advances in additive manufacturing techniques, present a unique opportunity to completely re-envision the design, manufacture, and supply chain of stents. This paper looks at current stenting trends and proposes a future where the stent supply chain is condensed from ~150 days to ~20 min. The Cardiologist therefore has the opportunity to become a designer, manufacturer and user with patients receiving custom stents specific to their unique pathology that will be generated, delivered and deployed in the Cath-lab. The paper will outline this potentially revolutionary development and consider the technical challenges that will need to be overcome in order to achieve these ambitious goals. A high level overview of the generating eluting stents in situ program-GENESIS-is outlined including some early experimental work.
Clinical experience in coronary stenting with the Vivant Z Stent.
Chee, K H; Siaw, F S; Chan, C G; Chong, W P; Imran, Z A; Haizal, H K; Azman, W; Tan, K H
2005-06-01
This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
Revascularisation strategy for diabetic multivessel coronary arteriopathy.
Raghuram, A R
2006-04-01
Multivessel diffuse coronary arteriopathy is the hallmark of chronic diabetic patients. The ideal method of revascularising this group of patients is controversial. This review examines the various modalities available in the revascularisation of coronary artery disease in diabetic patients. Various trials have been conducted to compare the effectiveness of surgical and percutaneous methods of revascularisation. Most of the important trials like BARI, CABRI, EMORY and Duke's database are critically analysed and a meaningful practical strategy to manage this difficult subgroup of patients is outlined. The recommendations may change after a few years if the new coated stents prove their worth.
Yamaguchi, Tetsuo; Miyamoto, Takamichi; Kawahatsu, Kandoh; Nozato, Toshihiro
2017-07-19
A 73-year-old man, who had undergone coronary artery bypass grafting (CABG) 10 days prior, presented with a great saphenous vein graft aneurysm (SVGA). CT revealed the increasing size of the aneurysm. Since the SVGA occurred immediately after CABG and there were no other complications, the aneurysm was treated percutaneously. While intravascular ultrasonography (IVUS) and optical coherence tomography failed to detect the entry point, an IVUS catheter with the addition of ChromaFlo imaging clearly revealed the entry point, size and length of the SVGA. To prevent migration and edge restenosis associated with covered stents, the covered stent (3.0×19 mm) was superimposed on a drug-eluting stent (3.0×28 mm) that covered the entry site. A follow-up study demonstrated the absence of flow into the aneurysm. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Treatment for Stable Coronary Artery Disease: A Network Meta-Analysis of Cost-Effectiveness Studies
Caruba, Thibaut; Katsahian, Sandrine; Schramm, Catherine; Charles Nelson, Anaïs; Durieux, Pierre; Bégué, Dominique; Juillière, Yves; Dubourg, Olivier
2014-01-01
Introduction and Objectives Numerous studies have assessed cost-effectiveness of different treatment modalities for stable angina. Direct comparisons, however, are uncommon. We therefore set out to compare the efficacy and mean cost per patient after 1 and 3 years of follow-up, of the following treatments as assessed in randomized controlled trials (RCT): medical therapy (MT), percutaneous coronary intervention (PCI) without stent (PTCA), with bare-metal stent (BMS), with drug-eluting stent (DES), and elective coronary artery bypass graft (CABG). Methods RCT comparing at least two of the five treatments and reporting clinical and cost data were identified by a systematic search. Clinical end-points were mortality and myocardial infarction (MI). The costs described in the different trials were standardized and expressed in US $ 2008, based on purchasing power parity. A network meta-analysis was used to compare costs. Results Fifteen RCT were selected. Mortality and MI rates were similar in the five treatment groups both for 1-year and 3-year follow-up. Weighted cost per patient however differed markedly for the five treatment modalities, at both one year and three years (P<0.0001). MT was the least expensive treatment modality: US $3069 and 13 864 after one and three years of follow-up, while CABG was the most costly: US $27 003 and 28 670 after one and three years. PCI, whether with plain balloon, BMS or DES came in between, but was closer to the costs of CABG. Conclusions Appreciable savings in health expenditures can be achieved by using MT in the management of patients with stable angina. PMID:24896266
Fourth update on CT angiography of coronary stents: in vitro evaluation of 24 novel stent types.
Hickethier, Tilman; Wenning, Justus; Doerner, Jonas; Maintz, David; Michels, Guido; Bunck, Alexander C
2017-01-01
Background Non-invasive evaluation of coronary stent patency by coronary computed tomography angiography (cCTA) remains challenging. Multiple studies showed that CT technology but also individual stent design strongly influence the assessability of coronary stents by cCTA. Purpose To expand the available data on cCTA characteristics of coronary stents by 24 novel types to help interpreting examinations of patients after stent placement and selecting which stents are suitable for assessment by cCTA. Material and Methods Twenty-four novel coronary stents (17 cobalt-chromium, six stainless-steel, one platinum-chromium) were examined in a coronary phantom. Standard cCTA parameters with stent-specific algorithms were used. Image quality was quantified for each stent using established parameters (in-stent attenuation alteration and visible lumen diameter). Results Most stents (n = 14) showed lumen visibilities of 45-55%. No severe restriction of lumen visibility (>60%) was found. The majority of stents (n = 13) caused only small intraluminal attenuation deviations and no severe alterations (>20%) were found. When grouped by manufacturing material, no significant differences were found between cobalt-chromium and stainless-steel with identical mean visible diameters (1.52 ± 0.17 mm vs. 1.52 ± 0.13 mm) and comparable attenuation alterations (35.04 ± 16.56 HU vs. 21.25 ± 14.60 HU). The only platinum-chromium stent showed a smaller visible diameter (1.23 mm) and higher attenuation alteration (41.70 HU), but was also deemed to be assessable by cCTA. Conclusion All 24 novel evaluated stents are eligible for non-invasive evaluation by cCTA without significant differences between cobalt-chromium and stainless-steel stents. This updated catalogue of CT appearances of current coronary stents may serve as reference when taking care of patients with stents in need of coronary imaging.
Hickethier, Tilman; Baeßler, Bettina; Kroeger, Jan Robert; Doerner, Jonas; Pahn, Gregor; Maintz, David; Michels, Guido; Bunck, Alexander C
Accurate assessment of coronary stents using non-invasive CT imaging remains challenging despite new stent materials and improvements in CT technology. Virtual monoenergetic (monoE) images reconstructed from dual energy CT acquisitions potentially decrease artifacts caused by coronary stents. A novel spectral detector technology provides monoE and conventional images simultaneously for all conducted scans. The purpose of our study was to systematically investigate the influence of different monoE reconstructions on the visualization of coronary stent lumen in comparison to conventional images. Ten different coronary stents (diameter 3.0 mm) embedded in plastic tubes filled with contrast agent (500 HU) were scanned with a 128-row spectral detector CT (IQon, Philips, 120 kV, 125 mAs). Images were reconstructed (0.67 mm slice thickness, 0.35 mm increment) with a stent-specific conventional reconstruction kernel and 6 different monoE settings (60, 70, 80, 90, 100, 150 keV). Image quality for each stent and reconstruction was quantified using established parameters: image noise (standard deviation (SD) within a standardized ROI), in-stent attenuation difference (mean attenuation difference between stented and non-stented lumen) and visible lumen diameter (mean visible diameter of the stented tube). Image noise was significantly lower in all monoE data dets compared to conventional images (conventional: 13.41, 60 keV: 11.62, 70 keV: 11.67, 80 keV: 11.69, 90 keV: 11.71, 100 keV: 11.75, 150 keV: 11.80 HU SD; p < 0.01). The in-stent attenuation difference was significantly smaller in monoE data with higher keV levels than in conventional images (conventional: 148.18, 60 keV: 154.13 p = 0.036, 70 keV: 143.43 p = 0.109, 80 keV: 137.25 p = 0.052, 90 keV: 133.02 p = 0.043, 100 keV: 130.12 p = 0.039, 150 keV: 123.99 HU p = 0.035). The visible lumen diameter was significantly greater in monoE data with higher keV levels than in conventional images (conventional: 0.65, 60 keV: 0.68 p = 0.542, 70 keV: 0.71 p = 0.053, 80 keV: 0.74 p < 0.01, 90 keV: 0.77 p < 0.01, 100 keV: 0.82 p < 0.01, 150 keV: 0.87 mm p < 0.01). In comparison to conventional CT images, well-established parameters for objective assessment of CT image quality for coronary stents are significantly improved by utilization of monoE reconstructions with adequate keV levels derived from data acquired on a novel spectral detector CT platform. Copyright © 2017 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.
Lutter, Christoph; Nothhaft, Matthias; Rzany, Alexander; Garlichs, Christoph D; Cicha, Iwona
2015-01-01
In coronary artery disease, highly stenosed arteries are frequently treated by stent implantation, which thereafter necessitates a dual-antiplatelet therapy (DAPT) in order to prevent stent-thrombosis. We hypothesized that specific patterns of microstructures on stents can accelerate endothelialisation thereby reducing their thrombogenicity and the DAPT duration. Differently designed, 2-5 μm high elevations or hollows were lithographically etched on silicon plates, subsequently coated with silicon carbide. Smooth silicon plates and bare metal substrates were used as controls. To assess attachment and growth of human umbilical vein endothelial cells under static or flow conditions, actin cytoskeleton was visualised with green phalloidin. Endothelial migration was assessed in a modified barrier assay. To investigate surface thrombogenicity, platelets were incubated on the structured surfaces in static and flow conditions, and visualised with fluorescein-conjugated P-selectin antibody. Images were taken with incident-light fluorescent microscope for non-transparent objects. Compared to smooth surface, flat cubic elevations (5 μm edge length) improved endothelial cell attachment and growth under static and dynamic conditions, whereas smaller, spiky structures (2 μm edge length) had a negative influence on endothelialisation. Endothelial cell migration was fastest on flat cubic elevations, hollows, and smooth surfaces, whereas spiky structures and bare metal had a negative effect on endothelial migration. Thrombogenicity assays under static and flow conditions showed that platelet adhesion was reduced on the flat elevations and the smooth surface, as compared to the spiky structures, the hollow design and the bare metal substrates. Surface microstructures strongly influence endothelialisation of substrates. Designing stents with surface topography which accelerates endothelialisation and reduces thrombogenicity may be of clinical benefit by improving the safety profile of coronary interventions.
Intracarotid abciximab injection to abort impending ischemic stroke during carotid angioplasty.
Ho, D S; Wang, Y; Chui, M; Wang, Y; Ho, S L; Cheung, R T
2001-01-01
Abciximab, a platelet glycoprotein IIb/IIIa receptor antagonist, prevents ischemic complications during percutaneous transluminal coronary angioplasty and was recently shown to open occluded vessels in patients with acute myocardial infarction when used alone or in combination with other thrombolytic agents. In an animal model of arterial thrombosis, abciximab was found to be safe and effective for the prevention of carotid artery thrombosis. However, the safety and efficacy of abciximab in the treatment of acute ischemic cerebrovascular events is unknown at present. We describe 3 patients who experienced ischemic cerebrovascular events with symptoms involving the middle cerebral artery territory while undergoing percutaneous angioplasty and stenting to their internal carotid arteries. Abciximab was administered to each patient within 10 min of symptom onset as a bolus (0.25 mg/kg) into the ipsilateral common carotid artery followed by continuous intravenous infusion (9 microg/min) for 12 h. All patients' symptoms resolved completely (by 25 min, 40 min and 5 h, respectively) with no further neurological complications. Our preliminary observation suggests that abciximab may improve neurological outcome following middle cerebral artery ischemic events associated with carotid angioplasty and stenting. Large prospective studies are warranted to establish the safety and efficacy of abciximab in acute ischemic stroke, either as a primary treatment modality or an adjunct to carotid angioplasty and stenting. Copyright 2001 S. Karger AG, Basel.
Thiele, H; Desch, S; de Waha, S
2017-12-01
This article gives an update on the management of acute ST-segment elevation myocardial infarction (STEMI) according to the recently released European Society of Cardiology guidelines 2017 and the modifications are compared to the previous STEMI guidelines from 2012. Primary percutaneous coronary intervention (PCI) remains the preferred reperfusion strategy. New guideline recommendations relate to the access site with a clear preference for the radial artery, use of drug-eluting stents over bare metal stents, complete revascularization during the index hospitalization, and avoidance of routine thrombus aspiration. For periprocedural anticoagulation during PCI, bivalirudin has been downgraded. Oxygen treatment should be administered only if oxygen saturation is <90%. In cardiogenic shock, intra-aortic balloon pumps should no longer be used. New recommendations are in place with respect to the duration of dual antiplatelet therapy for patients without bleeding events during the first 12 months. Newly introduced sections cover myocardial infarction with no relevant stenosis of the coronary arteries (MINOCA), the introduction of new indicators for quality of care for myocardial infarction networks and new definitions for the time to reperfusion.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peynircioglu, Bora, E-mail: borapeynir@gmail.com; Geyik, Serdar; Yavuz, Kivilcim
2007-09-15
Purpose. To retrospectively assess the feasibility, safety, and clinical mid-term outcome of patients undergoing carotid artery stenting with stent-grafts. Methods. Over a 4 year period stent-grafts were used in the endovascular treatment of symptomatic internal carotid artery stenosis in 12 patients (2 women, 10 men, aged 47-83 (mean 64) years). Protection devices were not used. Possible microembolic complications were evaluated by magnetic resonance imaging (MRI) examinations of the brain before and the day after the procedure in all patients. Mean follow-up was 22 months (range 1-42 months), by Doppler ultrasonography and conventional angiography as well as clinical examination .Results. Themore » technical success rate was 100%. A total of 13 coronary stent-grafts were used. The mean stenosis rate (in terms of diameter) was 85% and the mean length of stent-grafts used was 20.9 mm. The mean diameter to which the stent-grafts were dilated was 4.66 mm. In-hospital complications occurred in 1 patient who suffered a minor femoral access hematoma that did not require transfusion or surgical decompression. Post-stenting diffusion-weighted MRI revealed several ipsilateral silent microemboli in only 1 case, which was completely asymptomatic. Two patients had a major stroke after 2 years of follow-up. Restenosis was found in 2 patients who underwent successful balloon dilatation followed by placement of a self-expandable bare stent within the stent-grafts. Conclusions. Stent-grafts may prevent microembolic complications during stenting of atherosclerotic carotid lesions in selected cases, offering immediate exclusion of the atherosclerotic lesion from the circulation by pressing the plaque against the vessel wall. Comparative, randomized studies in larger series of patients are needed with carotid-dedicated stent-graft designs.« less
Vaitkus, P T; Witmer, W T; Brandenburg, R G; Wells, S K; Zehnacker, J B
1997-10-01
We sought to broaden assessment of the economic impact of percutaneous transluminal coronary angioplasty (PTCA) revascularization salvage strategies by taking into account costs, revenues, the off-setting effects of prevented clinical complications and the effects of payer mix. Previous economic analyses of PTCA have focused on the direct costs of treatment but have not accounted either for associated revenues or for the ability of costly salvage techniques such as coronary stenting to reduce even costlier complications. Procedural costs, revenues and contribution margins (i.e., "profit") were measured for 765 consecutive PTCA cases to assess the economic impact of salvage techniques (prolonged heparin administration, thrombolysis, intracoronary stenting or use of perfusion balloon catheters) and clinical complications (myocardial infarction, coronary artery bypass graft surgery [CABG] or acute vessel closure with repeat PTCA). To assess the economic impact of various salvage techniques for failed PTCA, we used actual 1995 financial data as well as models of various mixes of fee-for-service, diagnosis-related group (DRG) and capitated payers. Under fee-for-service arrangements, most salvage techniques were profitable for the hospital. Stents were profitable at almost any level of clinical effectiveness. Under DRG-based systems, most salvage techniques such as stenting produced a financial loss to the hospital because one complication (CABG) remained profitable. Under capitated arrangements, stenting and other salvage modalities were profitable only if they were clinically effective in preventing complications in > 50% of cases in which they were used. The economic impact of PTCA salvage techniques depends on their clinical effectiveness, costs and revenues. In reimbursement systems dominated by DRG payers, salvage techniques are not rewarded, whereas complications are. Under capitated systems, the level of clinical effectiveness needed to achieve cost savings is probably not achievable in current practice. Further studies are needed to define equitable reimbursement schedules that will promote clinically effective practice.
Bioresorbable Electronic Stent Integrated with Therapeutic Nanoparticles for Endovascular Diseases.
Son, Donghee; Lee, Jongha; Lee, Dong Jun; Ghaffari, Roozbeh; Yun, Sumin; Kim, Seok Joo; Lee, Ji Eun; Cho, Hye Rim; Yoon, Soonho; Yang, Shixuan; Lee, Seunghyun; Qiao, Shutao; Ling, Daishun; Shin, Sanghun; Song, Jun-Kyul; Kim, Jaemin; Kim, Taeho; Lee, Hakyong; Kim, Jonghoon; Soh, Min; Lee, Nohyun; Hwang, Cheol Seong; Nam, Sangwook; Lu, Nanshu; Hyeon, Taeghwan; Choi, Seung Hong; Kim, Dae-Hyeong
2015-06-23
Implantable endovascular devices such as bare metal, drug eluting, and bioresorbable stents have transformed interventional care by providing continuous structural and mechanical support to many peripheral, neural, and coronary arteries affected by blockage. Although effective in achieving immediate restoration of blood flow, the long-term re-endothelialization and inflammation induced by mechanical stents are difficult to diagnose or treat. Here we present nanomaterial designs and integration strategies for the bioresorbable electronic stent with drug-infused functionalized nanoparticles to enable flow sensing, temperature monitoring, data storage, wireless power/data transmission, inflammation suppression, localized drug delivery, and hyperthermia therapy. In vivo and ex vivo animal experiments as well as in vitro cell studies demonstrate the previously unrecognized potential for bioresorbable electronic implants coupled with bioinert therapeutic nanoparticles in the endovascular system.
Preconditioning, postconditioning and their application to clinical cardiology.
Kloner, Robert A; Rezkalla, Shereif H
2006-05-01
Ischemic preconditioning is a well-established phenomenon first described in experimental preparations in which brief episodes of ischemia/reperfusion applied prior to a longer coronary artery occlusion reduce myocardial infarct size. There are ample correlates of ischemic preconditioning in the clinical realm. Preconditioning mimetic agents that stimulate the biochemical pathways of ischemic preconditioning and protect the heart without inducing ischemia have been examined in numerous experimental studies. However, despite the effectiveness of ischemic preconditioning and preconditioning mimetics for protecting ischemic myocardium, there are no preconditioning-based therapies that are routinely used in clinical medicine at the current time. Part of the problem is the need to administer therapy prior to the known ischemic event. Other issues are that percutaneous coronary intervention technology has advanced so far (with the development of stents and drug-eluting stents) that ischemic preconditioning or preconditioning mimetics have not been needed in most interventional cases. Recent clinical trials such as AMISTAD I and II (Acute Myocardial Infarction STudy of ADenosine) suggest that some preconditioning mimetics may reduce myocardial infarct size when given along with reperfusion or, as in the IONA trial, have benefit on clinical events when administered chronically in patients with known coronary artery disease. It is possible that some of the benefit described for adenosine in the AMISTAD 1 and 2 trials represents a manifestation of the recently described postconditioning phenomenon. It is probable that postconditioning--in which reperfusion is interrupted with brief coronary occlusions and reperfusion sequences--is more likely than preconditioning to be feasible as a clinical application to patients undergoing percutaneous coronary intervention for acute myocardial infarction.
Gyöngyösi, Mariann; Christ, Günter; Lang, Irene; Kreiner, Gerhard; Sochor, Heinz; Probst, Peter; Neunteufl, Thomas; Badr-Eslam, Rosa; Winkler, Susanne; Nyolczas, Noemi; Posa, Aniko; Leisch, Franz; Karnik, Ronald; Siostrzonek, Peter; Harb, Stefan; Heigert, Matthias; Zenker, Gerald; Benzer, Werner; Bonner, Gerhard; Kaider, Alexandra; Glogar, Dietmar
2009-08-01
The multicenter AUTAX (Austrian Multivessel TAXUS-Stent) registry investigated the 2-year clinical/angiographic outcomes of patients with multivessel coronary artery disease after implantation of TAXUS Express stents (Boston Scientific, Natick, Massachusetts), in a "real-world" setting. The AUTAX registry included patients with 2- or 3-vessel disease, with/without previous percutaneous coronary intervention (PCI) and concomitant surgery. Patients (n = 441, 64 +/- 12 years, 78% men) (n = 1,080 lesions) with possible complete revascularization by PCI were prospectively included. Median clinical follow-up was 753 (quartiles 728 to 775) days after PCI in 95.7%, with control angiography of 78% at 6 months. The primary end point was the composite of major adverse cardiac (nonfatal acute myocardial infarction [AMI], all-cause mortality, target lesion revascularization [TLR]) and cerebrovascular events (MACCE). Potential risk factor effects on 2-year MACCE were evaluated using Cox regression. Complete revascularization was successful in 90.5%, with left main PCI of 6.8%. Rates of acute, subacute, and late stent thrombosis were 0.7%, 0.5%, and 0.5%. Two-year follow-up identified AMI (1.4%), death (3.6%), stroke (0.2%), and TLR (13.1%), for a composite MACCE of 18.3%. The binary restenosis rate was 10.8%. The median of cumulative SYNTAX score was 23.0 (range 12.0 to 56.5). The SYNTAX score did not predict TLR or MACCE, due to lack of scoring of restenotic or bypass stenoses (29.8%). Age (hazard ratio [HR]: 1.03, p = 0.019) and acute coronary syndrome (HR: 2.1, p = 0.001) were significant predictors of 2-year MACCE. Incomplete revascularization predicted death or AMI (HR: 3.84, p = 0.002). With the aim of complete revascularization, TAXUS stent implantations can be safe for patients with multivessel disease. The AUTAX registry including patients with post-PCI lesions provides additional information to the SYNTAX (Synergy Between Percutaneous Coronary Intervention With TAXUS and Cardiac Surgery) study. (Austrian Multivessel TAXUS-Stent Registry; NCT00738686).
Kinnaird, Tim; Anderson, Richard; Ossei-Gerning, Nick; Cockburn, James; Sirker, Alex; Ludman, Peter; de Belder, Mark; Johnson, Thomas W; Copt, Samuel; Zaman, Azfar; Mamas, Mamas A
2017-09-01
The evidence base for coronary perforation (CP) occurring during percutaneous coronary intervention in patients with a history of coronary artery bypass surgery (PCI-CABG) is limited and the long-term effects unclear. Using a national PCI database, the incidence, predictors, and outcomes of CP during PCI-CABG were defined. Data were analyzed on all PCI-CABG procedures performed in England and Wales between 2005 and 2013. Multivariate logistic regressions and propensity scores were used to identify predictors of CP and its association with outcomes. During the study period, 309 CPs were recorded during 59 644 PCI-CABG procedures with the incidence rising from 0.32% in 2005 to 0.68% in 2013 ( P <0.001 for trend). Independent associates of perforation in native vessels included age, chronic occlusive disease intervention, rotational atherectomy use, number of stents, hypertension, and female sex. In graft PCI, predictors of perforation were history of stroke, New York Heart Association class, and number of stents used. In-hospital clinical complications including Q-wave myocardial infarction (2.9% versus 0.2%; P <0.001), major bleeding (14.0% versus 0.9%; P <0.001), blood transfusion (3.7% versus 0.2%; P <0.001), and death (10.0% versus 1.1%; P <0.001) were more frequent in patients with CP. A continued excess mortality occurred after perforation, with an odds ratio for 12-month mortality of 1.35 for perforation survivors compared with matched nonperforation survivors without a CP ( P <0.0001). CP is an infrequent event during PCI-CABG but is closely associated with adverse clinical outcomes. A legacy effect of perforation on 12-month mortality was observed. © 2017 American Heart Association, Inc.
Waksman, Ron; Ghali, Magdi; Goodroe, Randy; Ryan, Thomas; Turco, Mark; Ring, Michael; McGarry, Thomas; Dobies, David; Shammas, Nicolas; Steinberg, Daniel H; Swymelar, Stacy; Kaneshige, Kimberly; Torguson, Rebecca
2012-10-15
Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs. Copyright © 2012 Elsevier Inc. All rights reserved.
Ranjan, Alok; Patel, Tejas M; Shah, Sanjay C; Malhotra, Hemant; Patel, Rajni; Vayada, Nishith; Pothiwala, Rasesh; Fonseca, Keith; Tanwar, Narendra S
2005-01-01
Coronary angioplasty and stent implantation is effective as primary intervention in acute myocardial infarction. Because of fewer puncture site complications and improved patient comfort, transradial access has been increasingly used as an alternative to transfemoral access for percutaneous coronary interventions. We studied 103 patients (94 men, 9 women: mean age 52.5 +/- 11.96 years) with a diagnosis of acute myocardial infarction (<12 hours after onset), who underwent primary percutaneous coronary intervention. Transradial access was used in all patients with a normal Allen's test and transfemoral access was used additionally only if intra-aortic balloon counterpulsation was required. Follow-up duration was 6 months. Transradial access was successfully achieved in all patients. Radial artery cannulation took <2 min in more than 85% patients. During percutaneous coronary intervention, cannulation to balloon inflation times and total procedure times were 11.3 +/- 5.2 min and 19.9 +/- 10.8 min, respectively. Stents were implanted in 99 (96.1%) patients andplain balloon angioplastywas performed in 3.9%. The primary success rate was 98.1%, with no major bleeding complications. Total length of hospitalization averaged 2.4 +/- 0.8 days. In-hospital major adverse clinical events rate was 5.9%. Six-month clinical follow-up was achieved for 84 (86.6%) patients. Six (7.1%) patients died during follow-up. Follow-up coronary angiography was performed in 22 (26.2%) patients. After 6 months, 7 patients required revascularizationof the target lesion. The rate of survival without myocardial infarction, bypass surgery or repeat coronary angioplasty was 88.5% at 6 months. Transradial access may represent a safe and feasible technique for performing primary percutaneous coronary intervention with good acute results and without major bleeding complications.
Han, Yun-Fei; Liu, Wen-Hua; Chen, Xiang-Liang; Xiong, Yun-Yun; Yin, Qin-; Xu, Ge-Lin; Zhu, Wu-Sheng; Zhang, Ren-Liang; Ma, Min-Min; Li, Min-; Dai, Qi-Liang; Sun, Wen-; Liu, De-Zhi; Duan, Li-Hui; Liu, Xin-Feng
2016-08-01
Fractional flow reserve (FFR)-guided revascularization strategy is popular in coronary intervention. However, the feasibility of assessing stenotic severity in intracranial large arteries using pressure gradient measurements still remains unclear. Between March 2013 and May 2014, 12 consecutive patients with intracranial large artery stenosis (including intracranial internal carotid artery, middle cerebral M1 segment, intracranial vertebral artery, and basilar artery) were enrolled in this study. The trans-stenotic pressure gradient was measured before and/or after percutaneous transluminal angioplasty and stenting (PTAS), and was then compared with percent diameter stenosis. A Pd /Pa cut-off of ≤0.70 was used to guide stenting of hemodynamically significant stenoses. The device-related and procedure-related serious adverse events and recurrent cerebral ischemic events were recorded. The target vessel could be reached in all cases. No technical complications occurred due to the specific study protocol. Excellent pressure signals were obtained in all patients. For seven patients who performed PTAS, the mean pre-procedural pressure gradient decreased from 59.0 ± 17.2 to 13.3 ± 13.6 mm Hg after the procedure (P < 0.01). Only one patient who refused stenting experienced a TIA event in the ipsilateral MCA territory. No recurrent ischemic event was observed in other patients. Mean trans-stenotic pressure gradients can be safely and easily measured with a 0.014-inch fluid-filled guide wire in intracranial large arteries. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Li, Yan; Tellez, Armando; Rousselle, Serge D; Dillon, Krista N; Garza, Javier A; Barry, Chris; Granada, Juan F
2016-07-01
To evaluate the biological effect of a paclitaxel-coated balloon (PCB) technology on vascular drug distribution and healing in drug eluting stent restenosis (DES-ISR) swine model. The mechanism of action and healing response via PCB technology in DES-ISR is not completely understood. A total of 27 bare metal stents were implanted in coronary arteries and 30 days later the in-stent restenosis was treated with PCB. Treated segments were harvested at 1 hr, 14 days and 30 days post treatment for the pharmacokinetic analysis. In addition, 24 DES were implanted in coronary arteries for 30 days, then all DES-ISRs were treated with either PCB (n = 12) or uncoated balloon (n = 12). At day 60, vessels were harvested for histology following angiography and optical coherence tomography (OCT). The paclitaxel level in neointimal tissue was about 18 times higher (P = 0.0004) at 1 hr Cmax , and retained about five times higher (P = 0.008) at day 60 than that in vessel wall. A homogenous distribution of paclitaxel in ISR was demonstrated by using fluorescently labeled paclitaxel. Notably, in DES-ISR, both termination OCT and quantitative coronary angioplasty showed a significant neointimal reduction and less late lumen loss (P = 0.05 and P = 0.03, respectively) post PCB versus post uncoated balloon. The PES-ISR + PCB group displayed higher levels of peri-strut inflammation and fibrin scores compared to the -limus DES-ISR + PCB group. In ISR, paclitaxel is primarily deposited in neointimal tissue and effectively retained over time following PCB use. Despite the presence of metallic struts, a uniform distribution was characterized. PCB demonstrated an equivalent biological effect in DES-ISR without significantly increasing inflammation. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.
Li, Yan; Tellez, Armando; Rousselle, Serge D.; Dillon, Krista N.; Garza, Javier A.; Barry, Chris
2015-01-01
Objectives To evaluate the biological effect of a paclitaxel‐coated balloon (PCB) technology on vascular drug distribution and healing in drug eluting stent restenosis (DES‐ISR) swine model. Background The mechanism of action and healing response via PCB technology in DES‐ISR is not completely understood. Methods A total of 27 bare metal stents were implanted in coronary arteries and 30 days later the in‐stent restenosis was treated with PCB. Treated segments were harvested at 1 hr, 14 days and 30 days post treatment for the pharmacokinetic analysis. In addition, 24 DES were implanted in coronary arteries for 30 days, then all DES‐ISRs were treated with either PCB (n = 12) or uncoated balloon (n = 12). At day 60, vessels were harvested for histology following angiography and optical coherence tomography (OCT). Results The paclitaxel level in neointimal tissue was about 18 times higher (P = 0.0004) at 1 hr C max, and retained about five times higher (P = 0.008) at day 60 than that in vessel wall. A homogenous distribution of paclitaxel in ISR was demonstrated by using fluorescently labeled paclitaxel. Notably, in DES‐ISR, both termination OCT and quantitative coronary angioplasty showed a significant neointimal reduction and less late lumen loss (P = 0.05 and P = 0.03, respectively) post PCB versus post uncoated balloon. The PES‐ISR + PCB group displayed higher levels of peri‐strut inflammation and fibrin scores compared to the ‐limus DES‐ISR + PCB group. Conclusions In ISR, paclitaxel is primarily deposited in neointimal tissue and effectively retained over time following PCB use. Despite the presence of metallic struts, a uniform distribution was characterized. PCB demonstrated an equivalent biological effect in DES‐ISR without significantly increasing inflammation. © 2015 Wiley Periodicals, Inc. PMID:26613810
Ji, Lizhen; Liu, Chengyu; Li, Peng; Wang, Xinpei; Liu, Changchun; Hou, Yinglong
2018-01-08
Pulse wave transit time (PWTT) has been widely used as an index in assessing arterial stiffness. Percutaneous coronary intervention (PCI) is usually applied to the treatment of coronary artery disease (CAD). Research on the changes in PWTT caused by PCI is helpful for understanding the impact of the PCI procedure. In addition, effects of stent sites and access sites on the changes in PWTT have not been explored. Consequently, this study aimed to provide this information. The results showed that PWTT significantly increased after PCI (p < 0.01) while the standard deviation (SD) of PWTT time series had no statistically significant changes (p = 0.60) between before and after PCI. Significantly increased PWTT was found in the radial access group (p < 0.01), while there were no significant changes in the femoral access group (p > 0.4). Additionally, PWTT in the left anterior descending (LAD) group significantly increased after PCI (p < 0.01), but the increase that was found in the right coronary artery (RCA) group was not significant (p > 0.1). Our study indicates that arterial elasticity and left ventricular functions can benefit from a successful PCI procedure, and the increase of peripheral PWTT after PCI can help to better understand the effectiveness of the procedure.
How should I treat a patient to remove a fractured jailed side branch wire?
Owens, Colum G; Spence, Mark S
2011-08-01
A 53-year-old female was sent for diagnostic angiography after successful reperfusion therapy for an anterior ST-elevation myocardial infarct. The culprit lesion was a LAD/D1 bifurcation stenosis. Coronary angiography, intravascular ultrasound. Left anterior descending artery/first diagonal artery bifurcation stenosis, fractured jailed side branch wire. Provisional stenting strategy for bifurcation stenosis. Consideration of surgical and percutaneous options to retrieve fractured, jailed, side branch wire. Wire and balloon catheter wrap technique for retrieval of fractured wire.
[Magnetic resonance compatibility research for coronary mental stents].
Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren
2015-01-01
The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.
Hernández-Enríquez, Marco; Lairez, Olivier; Campelo-Parada, Francisco; Lhermusier, Thibault; Bouisset, Frédéric; Roncalli, Jérôme; Elbaz, Meyer; Carrié, Didier; Boudou, Nicolas
2018-05-28
To compare outcomes in patients receiving polytetrafluoroethylene (PTFE) and polyurethane (PL) covered stents (CS) after coronary artery perforation (CAP). The prognosis of CAP has improved with the advent of CSs. Information is scarce about the outcomes of new-generation CSs. Sixty-one patients were treated with CSs in a 5-years period (age = 77 ± 8.75% males). Procedural and clinical data were retrospectively collected. The primary endpoint was procedural success. Secondary endpoints included death and major adverse cardiac events (MACE) defined as a composite of death, myocardial infarction, target vessel, and lesion revascularization and need for surgical repair). Twenty-two (36%) received PL-CSs and 39 (65%) PTFE-CSs. There were no differences in procedural success (86% vs 69%, P = 0.216). Time to deliver was shorter with PL-CS despite larger length of stents (8[11] vs 15[16] min, P = 0.001; 20[5] vs 16[3] mm, P < 0.001). This group had lower rate of pericardial effusion and cardiac arrest (41% vs 72%, P = 0.028; 5% vs 26%, P = 0.045). At 1-year follow-up, MACE rates were similar (58% vs 56%, P = 1.000) with atrend toward TVR in the PL-CS arm (21% vs 5%, P = 0.083). No differences were found in mortality (26% vs 41%, P = 0.385). Each group had 1 stent thrombosis and in-stent restenosis trended higher in the PL-CS group (12% vs 3%, P = 0.223). Time to deliver was shorter with the PL-CS and resulted in lower rate of pericardial effusion and cardiac arrest. However, there were no significant differences in procedural success and 1-year follow-up MACE in patients treated with PL-CS or PTFE-CS. © 2018, Wiley Periodicals, Inc.
Vlachojannis, Georgios J; Smits, Pieter C; Hofma, Sjoerd H; Togni, Mario; Vázquez, Nicolás; Valdés, Mariano; Voudris, Vassilis; Slagboom, Ton; Goy, Jean-Jaques; den Heijer, Peter; van der Ent, Martin
2017-06-26
This analysis investigates the 5-year outcomes of the biodegradable polymer biolimus-eluting stent (BP-BES) and durable polymer everolimus-eluting stent (DP-EES) in an all-comers population undergoing percutaneous coronary intervention. Recent 1- and 3-year results from randomized trials have indicated similar safety and efficacy outcomes of BP-BES and DP-EES. Whether benefits of the biodegradable polymer device arise over longer follow-up is unknown. Moreover, in-depth, prospective, long-term follow-up data on metallic drug-eluting stents with durable or biodegradable polymers are scarce. The COMPARE II trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent) was a prospective, randomized, multicenter, all-comers trial in which 2,707 patients were randomly allocated (2:1) to BP-BES or DP-EES. The pre-specified endpoint at 5 years was major adverse cardiac events, a composite of cardiac death, nonfatal myocardial infarction, or target vessel revascularization. Five-year follow-up was available in 2,657 patients (98%). At 5 years, major adverse cardiac events occurred in 310 patients (17.3%) in the BP-BES group and 142 patients (15.6%) in the DP-EES group (p = 0.26). The rate of the combined safety endpoint all-cause death or myocardial infarction was 15.0% in the BP-BES group versus 14.8% in the DP-EES group (p = 0.90), whereas the efficacy measure target vessel revascularization was 10.6% versus 9.0% (p = 0.18), respectively. Interestingly, definite stent thrombosis rates did not differ between groups (1.5% for BP-BES vs. 0.9% for DP-EES; p = 0.17). The 5-year analysis comparing biodegradable polymer-coated BES and the durable polymer-coated EES confirms the initial early- and mid-term results regarding similar safety and efficacy outcomes in this all-comers percutaneous coronary intervention population. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Bypassing Bypass Surgery and Other Success Stories from the National Institutes of Health
Nijhara, Ruchika; Tidwell, J. Lille; Ferguson, Steven; Balakrishnan, Krishna
2009-01-01
After a heart attack, patients often undergo a procedure to open up the clogged artery and install a tiny meshlike device called a stent to keep the artery propped open. In most cases, the body reacts to this foreign object with scar-tissue formation, and the artery narrows again. To combat this re-clogging process, National Institutes of Health inventors developed paclitaxel-coated stents and later licensed it to Angiotech. Approved by the Food and Drug Administration in March 2004, these stents are expected to substantially reduce the use of coronary artery bypass surgery, an expensive operation now performed annually on 350,000-plus Americans. This and three other examples of NIH licensing success stories are described in this paper: (a) Kepivance, which improves the quality of life for cancer patients by eliminating mouth sores, (b) AIDS drug ddI, an important component of many combination drug therapies, and (c) Vitravene, the first and only antisense drug to be approved by FDA. These four examples will illustrate the success not only of the NIH licensing program, but also the innovative approaches taken by NIH inventors and the persistence of its commercial partners. This paper also highlights the business and legal lessons learned from these four cases. PMID:23730679
Gao, Yang; Lu, Bin; Hou, Zhi Hui; Yu, Fang Fang; Yin, Wei Hua; Wang, Zhi Qiang; Wu, Yong Jian; Mu, Chao Wei; Meinel, Felix G; McQuiston, Andrew D; Schoepf, U Joseph
2015-05-01
To determine whether changes in coronary opacification normalized to the aorta (corrected coronary opacification [CCO]) across stents can help identify in-stent restenosis (ISR) severity with use of invasive coronary angiography as the standard of reference. This study was approved by the institutional review board, and the requirement to obtain informed consent was waived. The authors retrospectively analyzed 106 patients (88 men, 18 women; mean age, 59.6 years ± 10.4; age range, 36-84 years) who had previously undergone stent implantation within 3 months of coronary computed tomographic (CT) angiography. Attenuation values in the coronary lumen were measured proximal and distal to the stents and normalized to the descending aorta. The CCO difference across the stent was compared with the severity of ISR. One-way analysis of variance least significant difference was used for comparison. A total of 141 stents were assessed. Seventy-six stents were normally patent, 18 had ISR of less than 50%, 28 had ISR of 50%-99%, and 19 were fully occluded. The median CCO differences in the four groups were 0.078, 0.163, 0.346, and 0.606, respectively. There was no significant difference between stents with an ISR of at least 50% and those with total occlusion (P = .056), although the other groups had significant differences at pairwise comparison (P < .01 for all). For stents smaller than 3 mm in diameter, the median CCO differences in the four groups were 0.086, 0.136, 0.390, and 0.471, respectively. The CCO differences across normal stents and stents with ISR of less than 50% were significantly less than those across stents with an ISR of at least 50% and those with total occlusion (P < .01 for all). There were no significant differences between stents with no ISR and those with an ISR of less than 50% (P = .821) and between stents with an ISR of at least 50% and those with an ISR of 100% (P = .836). The CCO difference across coronary stents is related to ISR severity in obstructive ISR in stents smaller than 3 mm in diameter. © RSNA, 2014.
Boyer, Nathan; Gupta, Rajesh; Schevchuck, Alex; Hindnavis, Vindhya; Maliske, Seth; Sheldon, Mark; Drachman, Douglas; Yeghiazarians, Yerem
2014-06-01
Coronary artery aneurysm (CAA) is an uncommon clinical finding, with an incidence varying from 1.5%-4.9% in adults, and is usually considered a variant of coronary artery disease (CAD). CAA identified in the context of acute coronary syndrome (ACS) represents a unique management challenge, particularly if the morphology of the CAA is suspected to have provoked the acute clinical syndrome. CAA is associated with thrombus formation due to abnormal laminar flow, as well as abnormal platelet and endothelial-derived pathophysiologic factors within the CAA. Once formed, mural thrombus may potentiate the deposition of additional thrombus within aneurysmal segments. Percutaneous revascularization of CAA has been associated with complications including distal embolization of thrombus, no-reflow phenomenon, stent malapposition, dissection, and rupture. Presently, there are no formal guidelines to direct the management of CAA in patients presenting with ACS; controversies exist whether conservative, surgical, or catheter-based management should be pursued. In this manuscript, we present an extensive review of the existing literature and associated clinical guidelines, and propose a management algorithm for patients with this complex clinical scenario. Armed with this perspective, therapeutic decisions may be tailored to synthesize patient factors and preferences, individualized clinical assessment, and existing American Heart Association/American College of Cardiology guidelines for management of ACS.
Causes of Death Following PCI Versus CABG in Complex CAD: 5-Year Follow-Up of SYNTAX.
Milojevic, Milan; Head, Stuart J; Parasca, Catalina A; Serruys, Patrick W; Mohr, Friedrich W; Morice, Marie-Claude; Mack, Michael J; Ståhle, Elisabeth; Feldman, Ted E; Dawkins, Keith D; Colombo, Antonio; Kappetein, A Pieter; Holmes, David R
2016-01-05
There are no data available on specific causes of death from randomized trials that have compared coronary artery bypass grafting (CABG) with percutaneous coronary intervention (PCI). The purpose of this study was to investigate specific causes of death, and its predictors, after revascularization for complex coronary disease in patients. An independent Clinical Events Committee consisting of expert physicians who were blinded to the study treatment subclassified causes of death as cardiovascular (cardiac and vascular), noncardiovascular, or undetermined according to the trial protocol. Cardiac deaths were classified as sudden cardiac, related to myocardial infarction (MI), and other cardiac deaths. In the randomized cohort, there were 97 deaths after CABG and 123 deaths after PCI during a 5-year follow-up. After CABG, 49.4% of deaths were cardiovascular, with the greatest cause being heart failure, arrhythmia, or other causes (24.6%), whereas after PCI, the majority of deaths were cardiovascular (67.5%) and as a result of MI (29.3%). The cumulative incidence rates of all-cause death were not significantly different between CABG and PCI (11.4% vs. 13.9%, respectively; p = 0.10), whereas there were significant differences in terms of cardiovascular (5.8% vs. 9.6%, respectively; p = 0.008) and cardiac death (5.3% vs. 9.0%, respectively; p = 0.003), which were caused primarily by a reduction in MI-related death with CABG compared with PCI (0.4% vs. 4.1%, respectively; p <0.0001). Treatment with PCI versus CABG was an independent predictor of cardiac death (hazard ratio: 1.55; 95% confidence interval: 1.09 to 2.33; p = 0.045). The difference in MI-related death was seen largely in patients with diabetes, 3-vessel disease, or high SYNTAX (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries) trial scores. During a 5-year follow-up, CABG in comparison with PCI was associated with a significantly reduced rate of MI-related death, which was the leading cause of death after PCI. Treatments following PCI should target reducing post-revascularization spontaneous MI. Furthermore, secondary preventive medication remains essential in reducing events post-revascularization. (TAXUS Drug-Eluting Stent Versus Coronary Artery Bypass Surgery for the Treatment of Narrowed Arteries [SYNTAX]; NCT00114972). Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Turrini, Fabrizio; Messora, Roberto; Giovanardi, Paolo; Tondi, Stefano; Magnavacchi, Paolo; Cavani, Rita; Tosoni, Giandomenico; Cappelli, Carlo; Pellegrini, Elisa; Romano, Stefania; Baldini, Augusto; Zennaro, Romeo Giulietto; Bondi, Marco
2009-12-23
Coronary artery disease is the leading cause of morbidity and mortality in patients with type 2 diabetes. Screening for asymptomatic coronary artery disease with treatment by means of revascularization seems to be an appealing option for prevention. The utility of such a strategy has never been challenged in a randomized trial. In the present study a cohort of diabetic patients without any symptoms and without known coronary artery disease will be screened at two diabetes outpatients services. Those with intermediate or high risk (equal or greater than 10% according to the Italian risk chart) will be asked to participate and enrolled. They will be seen and followed in order to provide the best adherence to medical therapy. Half of the patients will be randomized to undergo an exercise tolerance testing while the other group will continue to be regularly seen at diabetes outpatients services. Best medical/behavioral therapy will be offered to both groups. Those patients with a positive exercise tolerance testing will be studied by coronary angiography and treated according to the severity of coronary lesions by percutaneous stenting or surgery.The objective of the study is to evaluate the efficacy of the screening strategy aimed at revascularization. A cost-effectiveness analysis will be performed at the end of the follow up. The study will provide useful information about prevention and treatment of diabetic patients at high risk of coronary events. It will be made clearer if detection of silent coronary artery disease has to be recommended and followed by treatment. Given the simplicity of the study protocol, it will be easily transferable to the real world. (ClinicalTrials.gov): NCT00547872.
2009-01-01
Background Coronary artery disease is the leading cause of morbidity and mortality in patients with type 2 diabetes. Screening for asymptomatic coronary artery disease with treatment by means of revascularization seems to be an appealing option for prevention. The utility of such a strategy has never been challenged in a randomized trial. Methods/Design In the present study a cohort of diabetic patients without any symptoms and without known coronary artery disease will be screened at two diabetes outpatients services. Those with intermediate or high risk (equal or greater than 10% according to the Italian risk chart) will be asked to participate and enrolled. They will be seen and followed in order to provide the best adherence to medical therapy. Half of the patients will be randomized to undergo an exercise tolerance testing while the other group will continue to be regularly seen at diabetes outpatients services. Best medical/behavioral therapy will be offered to both groups. Those patients with a positive exercise tolerance testing will be studied by coronary angiography and treated according to the severity of coronary lesions by percutaneous stenting or surgery. The objective of the study is to evaluate the efficacy of the screening strategy aimed at revascularization. A cost-effectiveness analysis will be performed at the end of the follow up. Discussion The study will provide useful information about prevention and treatment of diabetic patients at high risk of coronary events. It will be made clearer if detection of silent coronary artery disease has to be recommended and followed by treatment. Given the simplicity of the study protocol, it will be easily transferable to the real world. Trial registration (ClinicalTrials.gov): NCT00547872 PMID:20030830
Management of Retained Intervention Guide-wire: A Literature Review
Al-Moghairi, Abdulrahman M; Al-Amri, Hussein S
2013-01-01
Percutaneous coronary angioplasty is increasingly employed in the treatment of patients with complex coronary artery disease. Different steerable guide wires used to open occluded vessel and facilitate balloon and stent deployment. However, the guide-wire itself is not without hazard: it may perforate or dissect the vessel, but fracture or entrapment is uncommon. Its management depends on the clinical situation of the patient, as well as the position and length of the remnant. In this review we discuss the angioplasty guide-wire fracture and entrapment risk factors, potential risks and management. PMID:23116055
de la Torre-Hernández, José M; Alfonso, Fernando; Hernández, Felipe; Elizaga, Jaime; Sanmartin, Marcelo; Pinar, Eduardo; Lozano, Iñigo; Vazquez, Jose M; Botas, Javier; Perez de Prado, Armando; Hernández, Jose M; Sanchis, Juan; Nodar, Juan M Ruiz; Gomez-Jaume, Alfredo; Larman, Mariano; Diarte, Jose A; Rodríguez-Collado, Javier; Rumoroso, Jose R; Lopez-Minguez, Jose R; Mauri, Josepa
2008-03-11
This study sought to assess the incidence, predictors, and outcome of drug-eluting stent(DES) thrombosis in real-world clinical practice. The DES thromboses in randomized trials could not be comparable to those observed in clinical practice, frequently including off-label indications. We designed a large-scale, nonindustry-linked multicentered registry, with 20 centers in Spain. The participant centers provided follow-up data for their patients treated with DES, reporting a detailed standardized form in the event of any angiography-documented DES-associated thrombosis occurring. Of 23,500 patients treated with DES, definite stent thrombosis(ST) developed in 301: 24 acute, 125 subacute, and 152 late. Of the late, 62 occurred >1 year(very late ST). The cumulative incidence was 2% at 3 years. Antiplatelet treatment had been discontinued in 95 cases(31.6%). No differences in incidences were found among stent types. Independent predictors for subacute ST analyzed in a subgroup of 14,120 cases were diabetes, renal failure, acute coronary syndrome, ST-segment elevation myocardial infarction, stent length, and left anterior descending artery stenting, and for late ST were ST-segment elevation myocardial infarction, stenting in left anterior descending artery, and stent length. Mortality at 1-year follow-up was 16% and ST recurrence 4.6%. Older age, left ventricular ejection fraction <45%, nonrestoration of Thrombolysis In Myocardial Infarction flow grade 3, and additional stenting were independent predictors for mortality. The cumulative incidence of ST after DES implantation was 2% at 3 years. No differences were found among stent types. Patient profiles differed between early and late ST. Short-term prognosis is poor, especially when restoration of normal flow fails.
Cumberland, D C; Gunn, J; Malik, N; Holt, C M
1998-01-01
The surface properties of stents can be modified by coating them, for example with a polymer. Phosphorylcoline (PC) is the major component of the outer layer of the cell membrane. The haemo- and biocompatibility of a PC-containing polymer is thus based on biomimicry, and has been confirmed by several experiments showing much reduced thrombogenicity of PC-coated surfaces, and porcine coronary artery implants showing no sign of adverse effect. Clinical experience with the PC-coated BiodivYsio appears favourable. The PC coating can be tailored for take up and controlled elution of various drugs for stent-based local delivery, a property which is being actively explored.
Salwan, R; Mathur, A; Jhamb, D K; Seth, A
2001-09-01
Coronary perforation is an uncommon complication of angioplasty and is a challenging situation to manage. We describe a case of complex multivessel coronary angioplasty complicated by coronary perforation following balloon rupture that was successfully managed with a coronary stent graft. Delivery of the stent graft to the site of vessel rupture required deep intubation of an 8 Fr guiding catheter over the shaft of an inflated balloon. In addition to the availability of covered stents, it is essential to be familiar with various skills necessary to deploy these stents. Cathet Cardiovasc Intervent 2001;54:59-62. Copyright 2001 Wiley-Liss, Inc.
Multiple coronary stenting negatively affects myocardial recovery after coronary bypass grafting.
Yajima, Shin; Yoshioka, Daisuke; Fukushima, Satsuki; Toda, Koichi; Miyagawa, Shigeru; Yoshikawa, Yasushi; Hata, Hiroki; Saito, Shunsuke; Domae, Keitaro; Sawa, Yoshiki
2018-05-14
We aimed to elucidate the relationship between the magnitude of myocardial recovery after coronary artery bypass grafting (CABG) and the prognosis and to explore the predictors of myocardial non-recovery. Eighty-one patients with a preoperative left ventricular ejection fraction (LVEF) ≤ 40% who underwent isolated CABG between 2002 and 2015 and had undergone echocardiographic follow-up (median follow-up, 3.1 years; interquartile range 1.2-6.0 years) were analyzed. The Recovery group comprised patients with LVEF improvement ≥ 10%, whereas the Non-recovery group comprised those with an LVEF improvement < 10%. Group differences in overall survival, freedom from major adverse cardiac events (MACEs), and readmission due to heart failure were evaluated. In addition, the risk factors for LVEF non-recovery were evaluated in a multivariate analysis. A total of 39 patients (48%) were in the Recovery group, whereas 42 patients (52%) were in the Non-recovery group. Although the survival and freedom from MACE rates were comparable, the rate of freedom from heart failure requiring hospitalization at 1, 5, and 8 years of follow-up was significantly lower in the Non-recovery group than in the Recovery group (p = 0.012). A history of percutaneous coronary intervention (PCI) was an exclusive independent risk factor for post-CABG myocardial non-recovery (odds ratio, 16.0; 95% confidence interval, 3.44-125). Furthermore, the number of coronary stents was negatively correlated with LVEF recovery (r = - 0.460, p = 0.024). Great consideration should be taken when performing CABG in patients with left ventricular dysfunction and a history of PCI, particularly in those with multiple coronary stents.
Prevalence of Risk Factors for Coronary Artery Disease in Pennsylvania (USA) Firefighters.
Risavi, Brian L; Staszko, Jason
2016-02-01
Firefighting is a physically demanding profession. Heart disease remains the number one killer of firefighters. Many firefighters have multiple risk factors, putting them at risk for sudden cardiac events. The purpose of this study was to describe the prevalence of risk factors for heart disease in a convenience sample of Pennsylvania (USA) firefighters. A convenience sample of 160 firefighters in western Pennsylvania had height, weight, waist circumference, blood pressure, and body mass index (BMI) assessed, and then were surveyed to measure their knowledge of cardiovascular risk factors. Data analysis included subgroup comparisons of age, BMI, waist circumference, and exercise for their impact on health risks in the study cohort. In particular, the researchers were interested in understanding whether the knowledge of risk was associated with lower measures of risk. Eighteen firefighters (4%) reported a history of coronary artery disease (including stents/interventions). In this group, 69% to 82% correctly identified age, hypertension (HTN), high cholesterol, smoking, obesity, sedentary lifestyle, and family history as risk factors for coronary artery disease. Fourteen percent were smokers, 41% had HTN, 38% had pre-HTN with only 12% receiving treatment, and 13.5% were treated for high cholesterol. Fifty-eight percent exercised regularly. While a majority of firefighters were able to identify risk factors for coronary artery disease, many could not. Eighteen (4%) had a history of coronary artery disease, including interventions. Many had several of the risk factors indicated, which highlights the need for an organized national approach to address the medical screening/evaluation, nutrition, and exercise components of firefighter fitness.
Raja, Shahzad G.; Ilsley, Charles; De Robertis, Fabio; Lane, Rebecca; Kabir, Tito; Bahrami, Toufan; Simon, Andre; Popov, Aron; Dalby, Miles C.; Mason, Mark; Grocott-Mason, Richard; Smith, Robert D.
2018-01-01
Background Studies comparing coronary artery bypass graft (CABG) and percutaneous coronary intervention (PCI) have largely been performed in the bare-metal stent (BMS) and first-generation drug eluting stent (F-DES) era. Second-generation DES (S-DES) have shown improved outcomes when compared to F-DES, but data comparing CABG with PCI using S-DES is limited. We compared mortality following CABG versus PCI for patients with multivessel disease and analyzed different stent types. Methods A total of 6,682 patients underwent multivessel revascularization at Harefield Hospital, UK. We stratified CABG patients into single arterial graft (SAG) or multiple arterial grafts (MAG); and PCI patients into BMS, F-DES or S-DES groups. We analyzed all-cause mortality at 5 years. Results 4,388 patients had CABG (n[SAG] = 3,358; n[MAG] = 1,030) and 2,294 patients had PCI (n[BMS] = 416; n[F-DES] = 752; n[S-DES] = 1,126). PCI had higher 5-year mortality with BMS (HR = 2.27, 95% CI:1.70–3.05, p<0.001); F-DES (HR = 1.52, 95% CI:1.14–2.01, p = 0.003); and S-DES (HR = 1.84, 95% CI:1.42–2.38, p<0.001). This was confirmed in inverse probability treatment weighted analyses. When adjusting for both measured and unmeasured factors using instrumental variable analyses, PCI had higher 5-year mortality with BMS (Δ = 15.5, 95% CI:3.6,27.5, p = 0.011) and FDES (Δ = 16.5, 95% CI:6.6,26.4, p<0.001), but had comparable mortality with CABG for PCI with SDES (Δ = 0.9, 95% CI: -9.6,7.9, p = 0.844), and when exclusively compared to CABG patients with SAG (Δ = 0.4, 95% CI: -8.0,8.7, p = 0.931) or MAG (Δ = 4.6, 95% CI: -0.4,9.6, p = 0.931). Conclusions In this real-world analysis, when adjusting for measured and unmeasured confounding, PCI with SDES had comparable 5-year mortality when compared to CABG. This warrants evaluation in adequately-powered randomized controlled trials. PMID:29408926
Enhancement of endothelialisation of coronary stents by laser surface engineering.
Li, Lin; Mirhosseini, Nazanin; Michael, Alun; Liu, Zhu; Wang, Tao
2013-11-01
Coronary stents have been widely used in the treatment of coronary heart disease. However, complications have hampered the long-term success of the device. Bare-metal stents (BMS) have a high rate of restenosis and poor endothelialisation. The drug-eluting stents (DES), although dramatically reduce restenosis, significantly prevent endothelialisation leading to late thrombosis and behave the same way as BMS after drug releasing. Rapid adhesion and growth of endothelial cells on the stent surface is a key process for early vascular healing after coronary stenting which contributes to the reduction of major complications. Surface properties manipulate cell growth and directly determine the success and life-span of the implants. However, the ideal surface properties of coronary stents are not yet fully understood. The objective of this research is to understand how surface micro/nano textures and associated material chemistry changes generated by a laser beam affect the behavior of endothelial cells on bare metal 316L stents. A high power laser beam was applied to modifying the surface properties of 316L coronary stent material and the commercial coronary stents, followed by examination of the adhesion and proliferation of human coronary endothelial cells that were growing on the surfaces. Surface properties were examined by scanning electron microscopy, contact angle measurement, and X-ray photoelectron spectroscopy. A novel surface with combined micro/nano features was created on stent material 316L and coronary stent with a specific surface chemistry. This surface gives rise to a threefold increase in the adhesion and eightfold increase in the proliferation of endothelial cells. Interestingly, such effects were only observed when the surface texture was produced in the nitrogen atmosphere suggesting the importance of the surface chemistry, including the dramatic increase of chromium nitride, for the interaction of endothelial cells with the material surface. This novel surface is also super-hydrophilic with close to zero water/cell culture fluid contact angles and low cytotoxicity. A novel surface created by laser surface-engineering with a combination of defined surface texture and surface chemistry was found beneficial for the improvement of coronary stent endothelialisation. The technology presented here could work with both DES and BMS with added benefit for the improvement of the biocompatibility of current coronary stents. © 2013 Wiley Periodicals, Inc.
Shved, M; Tsuglevych, L; Kyrychok, I; Levytska, L; Boiko, T; Kitsak, Ya
2017-04-01
In patients with acute coronary syndrome (ACS) who underwent coronary arteries revascularization, violations of hemodynamics, metabolism and heart rate variability often develop in the postoperative period, therefore, the goal of the study was to establish the features of disturbances and the effectiveness of correction of left ventricular systolic and diastolic dysfunction and heart rate variability in stages of cardiorehabilitation in patients with acute coronary syndrome who underwent coronary arteries revascularization. The experimental group included 40 patients with ACS in the postoperative period who underwent balloon angioplasty and stenting of the coronary arteries (25 patients with ST-segment elevation ACS and 15 patients without ST-segment elevation ACS). The age of examined patients was 37 to 74 years, an average of 52.6±6.7 years. The control group consisted of 20 patients, comparable in age and clinico-laboratory manifestations of ACS, who underwent drug treatment with direct anticoagulants, double antiplatelet therapy, β-blockers, ACE inhibitors and statins. Clinical efficacy of cardiorespiratory process in patients of both groups was assessed by the dynamics of general clinical symptoms and parameters of natriuretic propeptide, systolic and diastolic function of the left ventricle and heart rate variability. In the initial state, clinical and laboratory-instrumental signs of myocardial ischemia disappear in patients with ACS undergoing surgical revascularization of the coronary arteries, but clinical and subclinical manifestations of heart failure were diagnosed. The use of the accelerated program of cardiac rehabilitation already during the first month of studies leads to a decreasement of the signs of systolic and diastolic dysfunction, the level of NT-proBNP and improve in the variability of the heart rhythm wich significantly improves the life quality of patients with ACS. To monitor the effectiveness and safety of cardiac rehabilitation in patients with ACS who underwent coronary arteries revascularization, in addition to the generally accepted methods (determination of heart rate, blood pressure, a 6-minute test), it is advisable to diagnose the subclinical stage of heart failure by determining the level of NT-proBNP, Doppler echocardiogram, parameters of the left ventricular systolic and diastolic function and heart rate variability.
Recent Advances in Drug Eluting Stents
Puranik, Amey S.; Dawson, Eileen R.; Peppas, Nicholas A.
2013-01-01
One of the most common medical interventions to reopen an occluded vessel is the implantation of a coronary stent. While this method of treatment is effective initially, restenosis, or the re-narrowing of the artery frequently occurs largely due to neointimal hyperplasia of smooth muscle cells. Drug eluting stents were developed in order to provide local, site-specific, controlled release of drugs that can inhibit neointima formation. By implementing a controlled release delivery system it may be possible to control the time release of the pharmacological factors and thus be able to bypass some of the critical events associated with stent hyperplasia and prevent the need for subsequent intervention. However, since the advent of first-generation drug eluting stents, long-term adverse effects have raised concerns regarding their safety. These limitations in safety and efficacy have triggered considerable research in developing biodegradable stents and more potent drug delivery systems. In this review, we shed light on the current state-of-the-art in drug eluting stents, problems related to them and highlight some of the ongoing research in this area. PMID:23117022
d'Errico, Michele; Sammarco, Paolo; Vairo, Giuseppe
2015-09-01
Pharmacokinetics induced by drug eluting stents (DES) in coronary walls is modeled by means of a one-dimensional multi-layered model, accounting for vessel curvature and non-homogeneous properties of the arterial tissues. The model includes diffusion mechanisms, advection effects related to plasma filtration through the walls, and bio-chemical drug reactions. A non-classical Sturm-Liouville problem with discontinuous coefficients is derived, whose closed-form analytical solution is obtained via an eigenfunction expansion. Soundness and consistency of the proposed approach are shown by numerical computations based on possible clinical treatments involving both hydrophilic and hydrophobic drugs. The influence of the main model parameters on drug delivery mechanisms is analyzed, highlighting the effects induced by vessel curvature and yielding comparative indications and useful insights into the concurring mechanisms governing the pharmacokinetics. Copyright © 2015. Published by Elsevier Inc.
Use of monorail PTCA balloon catheter for local drug delivery.
Trehan, Vijay; Nair, Girish M; Gupta, Mohit D
2007-01-01
We report the use of monorail coronary balloon as an infusion catheter to give bailout abciximab selectively into the site of stent thrombosis as an adjunct to plain old balloon angioplasty (POBA) in a patient of subacute stent thrombosis of the left anterior descending coronary artery. The balloon component (polyamide material) of the monorail balloon catheter was shaved off the catheter so that abciximab injected through the balloon port of the catheter exited out the shaft of the balloon catheter at the site from where the balloon material was shaved off. We believe that selective infusion with abciximab along with POBA established antegrade flow and relieved the patient's ischemia. In the absence of essential hardware to give intracoronary drugs in an emergency situation, one may employ our technique of infusion through a monorail balloon catheter after shaving the balloon component from the catheter.
Bhatt, Parloop; Parikh, Parth; Patel, Apurva; Chag, Milan; Chandarana, Anish; Parikh, Roosha; Parikh, Keyur
2015-06-01
The ORBIT I trial, a first-in-man study, was conducted to evaluate the safety and performance of the orbital atherectomy system (OAS) in treating de novo calcified coronary lesions. Fifty patients were enrolled between May and July 2008 based on several criteria, and were treated with the OAS followed by stent placement. The safety and performance of the OAS were evaluated by procedural success, device success, and overall major adverse cardiovascular event (MACE) rates, including cardiac death, myocardial infarction (MI) and need for target lesion revascularization (TLR). Our institution enrolled and treated 33 of the 50 patients and continued follow-up for 5 years. Average age was 54 years and 91% were males. Mean lesion length was 15.9 mm. Device success was 100%, and average number of orbital atherectomy devices (OAD) used per patient was 1.3. Stents were placed directly after OAS in 31/32 patients (96.9%). All stents (average stent per lesion 1.1) were successfully deployed with 0.3% residual stenosis. The overall cumulative MACE rate was 6.1% in-hospital, 9.1% at 30 days, 12.1% at 6 months, 15.2% at 2 years, 18.2% at 3 years and 21.2% at 5 years (4 total cardiac deaths). None of the patients had Q-wave MIs. Angiographic complications were observed in 5 patients. No flow/slow flow due to distal embolization was observed. The ORBIT I trial suggests that OAS treatment continues to offer a safe and effective method to change compliance of calcified coronary lesions to facilitate optimal stent placement in these difficult-to-treat patients. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Magnetoelastic galfenol as a stent material for wirelessly controlled degradation rates.
DeRouin, Andrew; Guillory, Roger; He, Weilue; Frost, Megan; Goldman, Jeremy; Ong, Keat Ghee
2018-03-23
The gold standard of care for coronary artery disease, a leading cause of death for in the world, is balloon angioplasty in conjunction with stent deployment. However, implantation injuries and long-term presence of foreign material often promotes significant luminal tissue growth, leading to a narrowing of the artery and severely restricted blood flow. A promising method to mitigate this process is the use of biodegradable metallic stents, but thus far they have either degraded too slowly (iron) or disappeared prematurely (magnesium). The present work investigates the use of a unique type of magnetic material, galfenol (iron-gallium), for postoperative wireless control of stent degradation rates. Due to its magnetoelastic property, galfenol experiences longitudinal micron-level elongations when exposed to applied magnetic fields, allowing generation of a microstirring effect that affect its degradation behavior. In vitro indirect cytotoxicity tests on primary rat aortic smooth muscle cells indicated that galfenol byproducts must be concentrated approximately seven times from collected 60 day degradation medium to cause ∼15% of death from all cells. Surface and cross-sectional characterization of the material indicate that galfenol (Fe 80 Ga 20 ) degradation rates (∼0.55% per month) are insufficient for stenting applications. While this material may not be ideal for comprising the entire stent, there is potential for use in combination with other materials. Furthermore, the ability to control degradation rates postimplantation opens new possibilities for biodegradable stents; additional magnetoelastic materials should be investigated for use in stenting applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018. © 2018 Wiley Periodicals, Inc.
Li, Xiao-hong; Zhao, Ying; Dong, Jianzeng; He, Yihua; Liu, Wenxu; Han, Jiancheng
2015-10-01
A 76-year-old man under stable hemodynamic condition was admitted to our hospital for delayed percutaneous coronary intervention following a diagnosis of acute inferior myocardial infarction. Bedside echocardiography revealed ventricular septal rupture at the basal posteroinferior wall with a large left-to-right shunt. Right ventricular free-wall intramyocardial dissection and tricuspid chordae rupture were noted. Coronary angiography demonstrated occlusion of the proximal right coronary artery, which was treated by balloon angioplasty and stenting. While preparing for surgical repair, the patient's overall cardiac and renal function deteriorated and surgery was contraindicated. The patient died 16 days after discharge. © 2014 Wiley Periodicals, Inc.
Tellez, Armando; Seifert, Paul S; Donskoy, Elina; Sushkova, Natalia; Pennington, Douglas E; Milewski, Krzysztof; Krueger, Christian G; Kaluza, Greg L; Eppihimer, Michael J; Huibregtse, Barbara A; Dawkins, Keith D; Granada, Juan F
2014-05-01
The utility of animal models for the prediction of drug-eluting stent (DES) efficacy in human clinical trials is still unclear. The familial hypercholesterolemic swine (FHS) model has been shown to induce a human-like neointimal response to bare metal stent (BMS) implantation. However, its utility to discriminate efficacy signals following DES implantation is unknown. In this study, we aimed to test the efficacy and healing response of several everolimus-eluting stent (EES) platforms in the coronary territory of the FHS. A total of 19 EES platforms (SYNERGY=6, SYNERGY½-dose=7, and PROMUS Element=6) and an identical BMS control (Element=6) were implanted into the coronary arteries of nine FHS. All implants were performed under intravascular ultrasound guidance using a 1.2 : 1 overstretch ratio. At 30 days, the vascular response to the implant was evaluated by quantitative coronary angiography, optical coherence tomography, and histology. At 28 days, all EES platforms showed a significant decrease in angiographic late lumen loss (between 27 and 37%) compared with the BMS control group. This finding was confirmed both by optical coherence tomography (mean neointimal thickness=28-42% reduction) and by histology (mean neointimal thickness=44-55% reduction). All EES platforms showed similar degrees of neointimal inhibition. The presence of moderate to severe para-strut inflammation was observed in 83% of the stent sections in the BMS group compared with 28.6% in the SYNERGY½-dose group and 0% in the SYNERGY and PROMUS groups (P=0.0002). There was a 68-95% reduction in MMP9 expression in the media in all EES platforms compared with the BMS controls. The presence of mild to moderate para-strut fibrin deposits ranged from 66.7 to 83.4% in all EES platforms compared with 16.7% in the EBMS group. The FHS coronary injury model showed the efficacy of several EES platforms compared with an identical BMS control. Everolimus eluted from different polymeric platforms showed lower levels of inflammation and slightly higher fibrin deposits compared with BMS controls.
Doros, Gheorghe; Massaro, Joseph M; Kandzari, David E; Waksman, Ron; Koolen, Jacques J; Cutlip, Donald E; Mauri, Laura
2017-11-01
Traditional study design submitted to the Food and Drug Administration to test newer drug-eluting stents (DES) for marketing approval is the prospective randomized controlled trial. However, several DES have extensive clinical data from trials conducted outside the United States that have led to utilization of a novel design using the Bayesian approach. This design was proposed for testing DES with bioresorbable polymer compared with DES most commonly in use today that use durable polymers for drug elution. This prospective, multicenter, randomized, controlled trial is designed to assess the safety and efficacy of the Orsiro bioresorbable polymer sirolimus-eluting stent (BP SES). Up to 1,334 subjects with up to 3 de novo or restenotic coronary artery lesions who qualify for percutaneous coronary intervention with stenting will be randomized 2:1 to the BP SES versus the Xience durable polymer everolimus-eluting stent (DP EES). Data from this trial will be combined with data from 2 similarly designed trials that also randomize subjects to BP SES and DP EES (BIOFLOW II, N=452 and BIOFLOW IV, N=579) by using a Bayesian approach. The primary end point is target lesion failure at 12 months post index procedure, defined as cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization, and the primary analysis is a test of noninferiority of the BP SES versus DP EES on the primary end point according to a noninferiority delta of 3.85%. Secondary end points include stent thrombosis and the individual components of target lesion failure. Subjects will be followed for 5 years after randomization. The BIOFLOW V trial offers an opportunity to assess clinical outcomes in patients treated with coronary revascularization using the Orsiro BP SES relative to a commonly used DP EES. The use of a Bayesian analysis combines a large randomized cohort of patients 2 two smaller contributing randomized trials to augment the efficiency of the comparison. Copyright © 2017 Elsevier Inc. All rights reserved.
Jurado-Román, Alfonso; Rubio-Alonso, Belén; García-Tejada, Julio; Sánchez-Pérez, Ignacio; López-Lluva, María T; Gómez-Blázquez, Iván; Velázquez-Martín, María T; Albarrán-González-Trevilla, Agustín; Hernández-Hernández, Felipe; Lozano-Ruíz-Poveda, Fernando
2017-10-26
To analyse systematic isolated post-dilatation of the side branch as a part of provisional stent technique. 1960 angioplasties performed in two centres were prospectively registered, of which 382 were coronary bifurcations with a side branch>2mm. In centre A, isolated post-dilatation of the side branch was performed regardless its impairment after main vessel stenting. In centre B, side branch post-dilatation was performed only if it was severely affected after stent implantation. There was no difference between the two centres in the rate of side branch affection after stent implantation (A: 44.6 vs B: 49.3%, p=0.48) nor in the procedural success rate (A: 98.6% vs B: 96.7%, p=0.45). After one-year follow-up, a reduction of cardiovascular events was observed in centre A (A: 4.4% vs B: 10.4%, p=0.043) with a trend towards lower cardiac mortality (A: 2.2% vs B: 6.5%, p=0.093) and stent thrombosis (A: 0% vs B: 2.6%, p=0.077). There were no differences in the rate of myocardial infarction related to the treated artery (A: 1.4% vs B: 3.9%, p=0.29), or target lesion revascularization (A: 1.4% vs. B: 3.2%, p=0.45). Systematic isolated post-dilatation of the side branch in the provisional stent technique was associated with a high angiographic success rate, and a low rate of cardiovascular events during follow-up. Although the study design does not allow definitive conclusions, this strategy could be considered a valid option in some cases or even as part of the provisional stent technique. Copyright © 2017 Elsevier Inc. All rights reserved.
Al-Ali, Firas; Barrow, Tom; Duan, Li; Jefferson, Anne; Louis, Susan; Luke, Kim; Major, Kevin; Smoker, Sandy; Walker, Sarah; Yacobozzi, Margaret
2011-09-01
Although atherosclerotic plaque in the carotid and coronary arteries is accepted as a cause of ischemia, vertebral artery ostium (VAO) atherosclerotic plaque is not widely recognized as a source of ischemic stroke. We seek to demonstrate its implication in some posterior circulation ischemia. This is a nonrandomized, prospective, single-center registry on consecutive patients presenting with posterior circulation ischemia who underwent VAO stenting for significant atherosclerotic stenosis. Diagnostic evaluation and imaging studies determined the likelihood of this lesion as the symptom source (highly likely, probable, or highly unlikely). Patients were divided into 4 groups in decreasing order of severity of clinical presentation (ischemic stroke, TIA then stroke, TIA, asymptomatic), which were compared with the morphological and hemodynamic characteristics of the VAO plaque. Clinical follow-up 1 year after stenting assessed symptom recurrence. One hundred fourteen patients underwent stenting of 127 lesions; 35% of the lesions were highly likely the source of symptoms, 53% were probable, and 12% were highly unlikely. Clinical presentation correlated directly with plaque irregularity and presence of clot at the VAO, as did bilateral lesions and presence of tandem lesions. Symptom recurrence at 1 year was 2%. Thirty-five percent of the lesions were highly likely the source of the symptoms. A direct relationship between some morphological/hemodynamic characteristics and the severity of clinical presentation was also found. Finally, patients had a very low rate of symptom recurrence after treatment. These 3 observations point strongly to VAO plaque as a potential source of some posterior circulation stroke.
Jinnouchi, Hiroyuki; Kuramitsu, Shoichi; Shinozaki, Tomohiro; Kobayashi, Yohei; Hiromasa, Takashi; Morinaga, Takashi; Mazaki, Toru; Sakakura, Kenichi; Soga, Yoshimitsu; Hyodo, Makoto; Shirai, Shinichi; Ando, Kenji
2015-01-01
Clinical outcomes of implantation of the newer-generation drug-eluting stent (DES) following rotational atherectomy for heavily calcified lesions remain unclear in the real-world setting. We enrolled 252 consecutive patients (273 lesions) treated with newer-generation DES following rotational atherectomy. The primary endpoint was the cumulative 2-year incidence of major adverse cardiovascular events (MACE), defined as cardiac death, myocardial infarction, clinically-driven target lesion revascularization, and definite stent thrombosis. Complete clinical follow-up information at 2-year was obtained for all patients. The mean age was 73.2±9.0 years and 155 patients (61.5%) were male. Cumulative 2-year incidence of MACE (cardiac death, myocardial infarction, clinically-driven target lesion revascularization and definite stent thrombosis) was 20.3% (7.0%, 2.1%, 18.1% and 2.1%, respectively). Predictors of MACE were presenting with acute coronary syndrome (hazard ratio [HR]: 3.80, 95% confidence interval [CI]: 1.29-11.2, P=0.02), hemodialysis (HR: 1.93, 95% CI: 1.04-3.56, P=0.04) and previous coronary artery bypass graft (HR: 2.26, 95% CI: 1.02-5.00, P=0.045). PCI for calcified lesions requiring rotational atherectomy is still challenging even in the era of newer-generation DES.
Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe
2014-01-01
Objectives To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. PMID:25378023
Valgimigli, Marco; Sabaté, Manel; Kaiser, Christoph; Brugaletta, Salvatore; de la Torre Hernandez, Jose Maria; Galatius, Soeren; Cequier, Angel; Eberli, Franz; de Belder, Adam; Serruys, Patrick W; Ferrante, Giuseppe
2014-11-04
To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis. © Valgimigli et al 2014.
Zbinden, Rainer; von Felten, Stefanie; Wein, Bastian; Tueller, David; Kurz, David J; Reho, Ivano; Galatius, Soren; Alber, Hannes; Conen, David; Pfisterer, Matthias; Kaiser, Christoph; Eberli, Franz R
2017-02-01
The British National Institute of Clinical Excellence (NICE) guidelines recommend to use drug-eluting stents (DES) instead of bare-metal stents (BMS) only in lesions >15 mm in length or in vessels <3 mm in diameter. We analyzed the impact of stent length and stent diameter on in-stent restenosis (ISR) in the BASKET-PROVE study population and evaluated the cost-effectiveness of DES compared to BMS. The BASKET-PROVE trial compared DES vs BMS in large coronary arteries (≥3 mm). We calculated incremental cost-effectiveness ratios (ICERs) and cost-effectiveness acceptability curves with regard to quality-adjusted life years (QALYs) gained and target lesion revascularizations (TLRs) avoided. A total of 2278 patients were included in the analysis. A total of 74 ISR in 63 patients were observed. In-stent restenosis was significantly more frequent in segments treated with a BMS compared to segments treated with a DES (5.4% vs 0.76%; P<.001). The benefit of a DES compared to a BMS regarding ISR was consistent among the subgroups of stent length >15 mm and ≤15 mm, respectively. With the use of DES in short lesions, there was only a minimal gain of 0.005 in QALYs. At a threshold of 10 000 CHF per TLR avoided, DES had a high probability of being cost-effective. In the BASKET-PROVE study population, the strongest predictor of ISR is the use of a BMS, even in patients in need of stents ≥3.0 mm and ≤15 mm lesion length and DES were cost-effective. This should prompt the NICE to reevaluate its recommendation to use DES instead of BMS only in vessels <3.0 mm and lesions >15 mm length. © 2016 John Wiley & Sons Ltd.
Previous coronary stent implantation and cardiac events in patients undergoing noncardiac surgery.
Cruden, Nicholas L M; Harding, Scott A; Flapan, Andrew D; Graham, Cat; Wild, Sarah H; Slack, Rachel; Pell, Jill P; Newby, David E
2010-06-01
Noncardiac surgery performed after coronary stent implantation is associated with an increased risk of stent thrombosis, myocardial infarction, and death. The influence of stent type and period of risk still have to be defined. We linked the Scottish Coronary Revascularisation Register with hospital admission data to undertake a Scotland-wide retrospective cohort study examining cardiac outcomes in all patients who received drug-eluting or bare-metal stents between April 2003 and March 2007 and subsequently underwent noncardiac surgery. Of 1953 patients, 570 (29%) were treated with at least 1 drug-eluting stent and 1383 (71%) with bare-metal stents only. There were no differences between drug-eluting and bare-metal stents in the primary end point of in-hospital mortality or ischemic cardiac events (14.6% versus 13.3%; P=0.3) or the secondary end points of in-hospital mortality (0.7% versus 0.6%; P=0.8) and acute myocardial infarction (1.2% versus 0.7%; P=0.3). Perioperative death and ischemic cardiac events occurred more frequently when surgery was performed within 42 days of stent implantation (42.4% versus 12.8% beyond 42 days; P<0.001), especially in patients revascularized after an acute coronary syndrome (65% versus 32%; P=0.037). There were no temporal differences in outcomes between the drug-eluting and bare-metal stent groups. Patients undergoing noncardiac surgery after recent coronary stent implantation are at increased risk of perioperative myocardial ischemia, myocardial infarction, and death, particularly after an acute coronary syndrome. For at least 2 years after percutaneous coronary intervention, cardiac outcomes after noncardiac surgery are similar for both drug-eluting and bare-metal stents.
Ling, Hua; Andrews, Ebony; Ombengi, David; Li, Fang
2018-06-01
Patients with peripheral arterial disease (PAD) undergoing percutaneous coronary intervention (PCI) are at elevated risk of ischemic and bleeding events. However, the optimal duration of dual antiplatelet therapy (DAPT) after PCI in patients with PAD remains unclear. A systematic literature search was performed through June 2017 using PubMed, EMBASE and Cochrane databases with the following key terms: "dual antiplatelet therapy", "P2Y12 inhibitor", "myocardial infarction", "percutaneous coronary intervention", "stent", "peripheral arterial disease", and "ankle-brachial index". The analysis was restricted to randomized trials published in English in patients with PAD receiving extended DAPT (> 12-month) after PCI. Overall analysis was performed using Review Manager 5.3 with the Mantel-Haenszel method. Two randomized controlled trials involving 895 patients were included in this review. Compared to the placebo group, there was no statistical significance in the occurrence of major adverse cardiovascular and cerebrovascular events (MACCE) in patients receiving extended DAPT (odds ratio (OR) 0.76, 95% confidence interval (CI) 0.37 - 1.57; P = 0.46). The results were associated with substantial heterogeneity (I 2 = 71%, P = 0.07). Extended DAPT was not significantly associated with increased moderate/severe bleeding events (OR 1.63, 95% CI 0.84 - 3.18; P = 0.15; I 2 = 0%, P = 0.59). The extended DAPT was associated with 82% relative risk reduction in the events of definite/probably stent thrombosis. Among patients with PAD, extended DAPT after PCI resulted in a non-significant difference in ischemic and bleeding events compared to placebo, respectively. The routine use of extended DAPT in this cohort should be carefully evaluated.
Cortese, Bernardo; Berti, Sergio; Biondi-Zoccai, Giuseppe; Colombo, Antonio; Limbruno, Ugo; Bedogni, Francesco; Cremonesi, Alberto; Silva, Pedro Leon; Sgueglia, Gregory A
2014-02-15
Drug-coated balloons are a new tool for the treatment of patients with coronary artery disease. The main feature of this technology is a rapid and homogenous transfer of an antiproliferative drug (paclitaxel) to the vessel wall just at the time of balloon inflation, when neointimal proliferation, in response to angioplasty, is the highest. Moreover, drug-coated balloons share adjuntive advantages over stents: the absence of permanent scaffold and polymer, the respect of the original coronary anatomy, and limited inflammatory stimuli, thereby allowing for short-term dual antiplatelet therapy. To this day, a lot of devices are available in the market, with limited scientific data for the vast majority of them. Thus, the Italian scientific society of interventional cardiologists GISE decided to coordinate the efforts of a group of reknown experts on the field, in order to obtain a Position Paper on the correct use of drug-coated balloons in all the settings of coronary artery disease, giving a class of indication to each one, based on the clinical evidence. This Position Paper represents a quick reference for operators, investigators, and manufactures to promote the understanding and the correct use of the drug-coated balloon technology in everyday clinical practice. Copyright © 2013 Wiley Periodicals, Inc.
Challenges of coronary angiography and intervention in patients previously treated by TAVI.
Blumenstein, Johannes; Kim, Won-Keun; Liebetrau, Christoph; Gaede, Luise; Kempfert, Joerg; Walther, Thomas; Hamm, Christian; Möllmann, Helge
2015-08-01
Since the beginning of the transcatheter aortic valve implantation (TAVI) era, many prosthetic valves have entered clinical practice. TAVI prostheses differ regarding stent design and some may potentially interfere with diagnostic or interventional catheters. The aim of our analysis was to evaluate the feasibility of coronary angiography (CA) or percutaneous coronary intervention (PCI) in patients with prior TAVI. From 2011 to 2014, 1,000 patients were treated by TAVI at our center using eight different valve prostheses (Symetis ACURATE TA and ACURATE TF; Medtronic CoreValve and Engager; JenaValve, SJM Portico; Edwards Lifesciences SAPIEN and SAPIEN XT). In this analysis, all patients were included who underwent either CA or PCI after TAVI. CA or PCI were rated as fully feasible when coronary ostia could be fully intubated, partially feasible when coronary arteries could be displayed only unselectively or unfeasible when coronary arteries could not be displayed. A total of 35 patients underwent CA/PCI after TAVI at our hospital. In all patients with valves implanted in a subcoronary position (SAPIEN n = 19; JenaValve n = 1), selective intubation was feasible using standard catheters. Out of 15 patients with valve types that are placed over the coronary ostia (CoreValve n = 10, ACURATE n = 4, Portico n = 1), selective intubation of coronary arteries was not possible in 9 cases, even with the use of different diagnostic catheters. Full accessibility was possible only in 3 cases. In 2 cases, display of the right CA was only feasible using unselective aortography. In 1 case, coronary arteries could not be displayed at all immediately after a valve-in-valve procedure. CA or PCI after TAVI is usually feasible. Devices that are placed in a partially supracoronary position, however, can interfere with diagnostic or guiding catheters and impede straightforward intervention, especially when the prosthesis is not implanted in the correct position.
Tandjung, Kenneth; Basalus, Mounir W Z; Sen, Hanim; Jessurun, Gillian A J; Danse, Peter W; Stoel, Martin; Linssen, Gerard C M; Derks, Anita; van Loenhout, Ton T; Nienhuis, Mark B; Hautvast, Raymond W M; von Birgelen, Clemens
2012-04-01
Drug-eluting stents (DES) are increasingly used for the treatment of coronary artery disease. An optimized DES performance is desirable to successfully treat various challenging coronary lesions in a broad population of patients. In response to this demand, third-generation DES with an improved deliverability were developed. Promus Element (Boston Scientific, Natick, MA) and Resolute Integrity (Medtronic Vascular, Santa Rosa, CA) are 2 novel third-generation DES for which limited clinical data are available. Accordingly, we designed the current multicenter study to investigate in an all-comers population whether the clinical outcome is similar after stenting with Promus Element versus Resolute Integrity. DUTCH PEERS is a multicenter, prospective, single-blinded, randomized trial in a Dutch all-comers population. Patients with all clinical syndromes who require percutaneous coronary interventions with DES implantation are eligible. In these patients, the type of DES implanted will be randomized in a 1:1 ratio between Resolute Integrity versus Promus Element. The trial is powered based on a noninferiority hypothesis. For each stent arm, 894 patients will be enrolled, resulting in a total study population of 1,788 patients. The primary end point is the incidence of target vessel failure at 1-year follow-up. DUTCH PEERS is the first randomized multicenter trial with a head-to-head comparison of Promus Element and Resolute Integrity to investigate the safety and efficacy of these third-generation DES. Copyright © 2012 Mosby, Inc. All rights reserved.
NOBLE and EXCEL: The debate for excellence in dealing with left main stenosis.
Kindi, Hamood Al; Samaan, Amir; Hosny, Hatem
2018-03-14
Left main coronary artery (LMCA) disease is associated with increased morbidity and mortality. Coronary artery bypass grafting surgery (CABG) has always been the standard revascularization strategy for this group of patients. However, with the recent developments in stents design and medical therapy over the past decade, several trials have been designed to evaluate the safety and efficacy of percutaneous coronary intervention (PCI) as an alternative to CABG surgery in patients with LMCA disease. Recently, the results of two major trials, EXCEL and NOBLE, comparing CABG versus PCI in this patient population have been released. In fact, the results of both trials might appear contradictory at first glance. While the EXCEL trial showed that PCI was non-inferior to CABG surgery, the NOBLE trial suggested that CABG surgery is a better option. In the following review, we will discuss some of the similarities and contrasts between these two trials and conclude with lessons to be learned to our daily practice.
NOBLE and EXCEL: The debate for excellence in dealing with left main stenosis
Kindi, Hamood Al; Samaan, Amir
Left main coronary artery (LMCA) disease is associated with increased morbidity and mortality. Coronary artery bypass grafting surgery (CABG) has always been the standard revascularization strategy for this group of patients. However, with the recent developments in stents design and medical therapy over the past decade, several trials have been designed to evaluate the safety and efficacy of percutaneous coronary intervention (PCI) as an alternative to CABG surgery in patients with LMCA disease. Recently, the results of two major trials, EXCEL and NOBLE, comparing CABG versus PCI in this patient population have been released. In fact, the results of both trials might appear contradictory at first glance. While the EXCEL trial showed that PCI was non-inferior to CABG surgery, the NOBLE trial suggested that CABG surgery is a better option. In the following review, we will discuss some of the similarities and contrasts between these two trials and conclude with lessons to be learned to our daily practice. PMID:29644230
Lee, Michael S; Shlofmitz, Evan; Shlofmitz, Richard; Sahni, Sheila; Martinsen, Brad; Chambers, Jeffrey
2016-09-01
The ORBIT II trial reported excellent outcomes in patients with severely calcified coronary lesions treated with orbital atherectomy. Severe calcification of the left main (LM) artery represents a complex coronary lesion subset. This study evaluated the safety and efficacy of coronary orbital atherectomy to prepare severely calcified protected LM artery lesions for stent placement. The ORBIT II trial was a prospective, multicenter clinical trial that enrolled 443 patients with severely calcified coronary lesions in the United States. The major adverse cardiac event (MACE) rate through 2 years post procedure, defined by cardiac death, myocardial infarction (CK-MB >3x upper limit of normal with or without a new pathologic Q-wave) and target-vessel revascularization, was compared in the LM and non-left main (NLM) groups. Among the 443 patients, a total of 10 underwent orbital atherectomy of protected LM artery lesions. At 2 years, there was no significant difference in the 2-year MACE rate in the LM and NLM groups (30.0% vs 19.1%, respectively; P=.36). Cardiac death was low in both groups (0% vs 4.4%, respectively; P=.99). Myocardial infarction occurred within 30 days in both groups (10.0% vs 9.7%, respectively; P=.99). Severe dissection, perforation, persistent slow flow, and persistent no reflow did not occur in the LM group. Abrupt closure occurred in 1 patient in the LM group. Orbital atherectomy for patients with heavily calcified LM coronary artery lesions is safe and feasible. Further studies are needed to assess the safety and efficacy of orbital atherectomy in patients with severely calcified LM artery lesions.
García Carrascal, P; García García, J; Sierra Pallares, J; Castro Ruiz, F; Manuel Martín, F J
2017-05-01
Stent implantation is a common procedure followed in arteries affected by atherosclerosis. This procedure can lead to other stenting-related problems. One of these is the deposition and accumulation of blood clots over stent struts. This process can have further consequences, in so far as it can introduce modifications to the flow pattern. This problem is especially critical in stented bifurcations, where resulting stent geometry is more complex. In this regard, a numerical study is presented of the effect on the flow pattern and platelet activation of blood clot depositions on the stent struts of a stented coronary bifurcation. The numerical model is first validated with experimental measurements performed for this purpose. Experiments considered a flow with suspended artificial thrombi, which naturally deposited on stent struts. The location and shape observed were used to create numerical thrombi. Following this, numerical simulations were performed to analyze the influence of the presence of thrombi depositions on parameters such as Time Averaged Wall Shear Stress, Oscillatory Shear Index or Relative Residence Time. Finally, a study was also carried out of the effect of different geometrical configurations, from a straight tube to a stented bifurcation model with thrombus depositions, on platelet activation.
Frey, Daniela; Billinger, Michael; Meier, Pascal; Beslac, Olgica; Grossenbacher, Raphael; Hänni, Beat; Hess, Otto M
2008-12-01
Vascular healing of intracoronary stents has been shown to be delayed in drug-eluting stents (DES) due to the cytotoxic compounds on the stent surface that prevent stent ingrowth and endothelialization. The lack of endothelialization explains the occurrence of late and very late stent thrombosis in DES. In 11 house swines (body weight 38-45 kg), 3 stents were implanted randomly into the 3 large epicardial coronary arteries, namely a bare-metal stent (BMS), a sirolimus-eluting stent with slow-release (SES) and a SES with extended-release (SESXR). Stent length was 18 mm, and stent diameter 3 mm. All stents were of identical design. Animals were followed for 3 (n = 3), 7 (n = 4) and 14 (n = 4) days, respectively. One animal died before implantation due to hyperthermia. On the day of explantation, the animals were euthanized and endothelialization was tested by scanning electron microscopy after drying and sputtering the samples. Endothelial coverage was determined semiquantitatively by 2 observers. Endothelialization was more rapid with BMS and SESXR than SES at 3 and 14 days. At 7 days there were no significant differences between the 2 SES. Endothelialization of intracoronary stents is faster with BMS and SESXR at 3 days than with SES. These differences persist at 14 days, suggesting delayed vascular healing with the slow-release SES.
Liu, Hai-bo; Xu, Bo; Qiao, Shu-bin; Yang, Yue-jin; Ma, Wei-hua; Qin, Xue-wen; Yao, Min; Wu, Yong-jian; Yuan, Jin-qing; Chen, Jue; You, Shi-jie; Dai, Jun; Xia, Ran; Li, Jian-jun; Chen, Ji-lin; Gao, Run-lin
2007-04-05
Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice. In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n = 93, Firebird group) or Excel stents (n = 97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups. Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P > 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 +/- 0.21) mm versus (0.14 +/- 0.20) mm (P = 0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital. Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.
A New Hemodynamic Ex Vivo Model for Medical Devices Assessment.
Maurel, Blandine; Sarraf, Christophe; Bakir, Farid; Chai, Feng; Maton, Mickael; Sobocinski, Jonathan; Hertault, Adrien; Blanchemain, Nicolas; Haulon, Stephan; Lermusiaux, Patrick
2015-11-01
In-stent restenosis (ISR) remains a major public health concern associated with an increased morbidity, mortality, and health-related costs. Drug-eluting stents (DES) have reduced ISR, but generate healing-related issues or hypersensitivity reactions, leading to an increased risk of late acute stent thrombosis. Assessments of new DES are based on animal models or in vitro release systems, which have several limitations. The role of flow and shear stress on endothelial cell and ISR has also been emphasized. The aim of this work was to design and first evaluate an original bioreactor, replicating ex vivo hemodynamic and biological conditions similar to human conditions, to further evaluate new DES. This bioreactor was designed to study up to 6 stented arteries connected in bypass, immersed in a culture box, in which circulated a physiological systolo-diastolic resistive flow. Two centrifugal pumps drove the flow. The main pump generated pulsating flows by modulation of rotation velocity, and the second pump worked at constant rotation velocity, ensuring the counter pressure levels and backflows. The flow rate, the velocity profile, the arterial pressure, and the resistance of the flow were adjustable. The bioreactor was placed in an incubator to reproduce a biological environment. A first feasibility experience was performed over a 24-day period. Three rat aortic thoracic arteries were placed into the bioreactor, immersed in cell culture medium changed every 3 days, and with a circulating systolic and diastolic flux during the entire experimentation. There was no infection and no leak. At the end of the experimentation, a morphometric analysis was performed confirming the viability of the arteries. We designed and patented an original hemodynamic ex vivo model to further study new DES, as well as a wide range of vascular diseases and medical devices. This bioreactor will allow characterization of the velocity field and drug transfers within a stented artery with new functionalized DES, with experimental means not available in vivo. Another major benefit will be the reduction of animal experimentation and the opportunity to test new DES or other vascular therapeutics in human tissues (human infrapopliteal or coronary arteries collected during human donation). Copyright © 2015 Elsevier Inc. All rights reserved.
Coronary revascularization in Japan. Part 2: comparison of facilities between 1997 and 1999.
Tsuchihashi, M; Tsutsui, H; Shihara, M; Shigematsu, H; Yamamoto, S; Koike, G; Kono, S; Takeshita, A
2001-12-01
A nation-wide survey on the procedures and facilities of coronary revascularization, percutaneous coronary intervention (PCI) and coronary artery bypass grafting (CABG) conducted by the Japanese Coronary Intervention Study (JCIS) group during 1997 revealed that PCI is more often used than CABG and is mainly carried out in low-volume facilities without surgical backup. The present study aimed to investigate the temporal changes in the usage of revascularization therapies and facilities from 1997 to 1999. A questionnaire was mailed in 1998 to the delegates of 1,086 PCI and 582 CABG facilities identified by the previous survey, and 89% of PCIs surveyed and 94% of CABGs surveyed reported back. The number of PCI procedures had increased by 19% from 97,831 to 116,479 and that of CABG procedures also increased by 21% from 16,374 to 19,846. The ratio of PCI to CABG was 5.9 in 1999, showing no significant change from 6.0 in 1997. In parallel, the number of PCI and CABG facilities increased from 888 to 941 and from 442 to 453, respectively. The use of coronary stents and other interventional devices increased during these 2 years. Coronary stents were used regardless of the annual procedural volume of the facilities, whereas other interventional devices, directional and rotational coronary atherectomy, were used mainly in the high-volume laboratories (p<0.01). Beating-heart, off-pump CABG had increased from 2% to 11% of total cases. Continued monitoring of trends in PCI and CABG facilities and procedures will be needed for nation-wide assessment of the use of new technology.
Badreldin, Hisham A; Carter, Danielle; Cook, Bryan M; Qamar, Arman; Vaduganathan, Muthiah; Bhatt, Deepak L
2017-08-01
The 3 phase 3 CHAMPION (Cangrelor vs Standard Therapy to Achieve Optimal Management of Platelet Inhibition) trials collectively demonstrated the safety of transitioning from cangrelor, a potent, parenteral rapidly-acting P2Y 12 inhibitor, to clopidogrel in patients who underwent percutaneous coronary intervention (PCI). However, variation in timing of therapy, site-specific binding, and drug half-lives may theoretically complicate switching to other oral P2Y 12 inhibitors. Since regulatory approval, limited data are available regarding the "real-world" safety and tolerability of transitioning to these more potent oral P2Y 12 antagonists. From November 2015 to January 2017, we evaluated the clinical profiles and efficacy and safety outcomes in cangrelor-treated patients who underwent PCI transitioned to clopidogrel (n = 42) or ticagrelor (n = 82) at a large, tertiary care center. Most patients receiving cangrelor underwent PCI with a drug-eluting stent for acute coronary syndrome via a radial approach in the background of unfractionated heparin. Stent thrombosis within 48 hours was rare and occurred in 1 patient treated with ticagrelor. Global Use of Strategies to Open Occluded Coronary Arteries-defined bleeding occurred in 20% of patients switched to ticagrelor and 29% of patients switched to clopidogrel, but none were severe or life-threatening. In conclusion, rates of stent thrombosis and severe/life-threatening bleeding were low and comparable with those identified in the CHAMPION program, despite use of more potent oral P2Y 12 inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.
Relation of Nickel Allergy with in-Stent Restenosis in Patients Treated with Cobalt Chromium Stents.
Aliağaoğlu, Cihangir; Turan, Hakan; Erden, Ismail; Albayrak, Hülya; Ozhan, Hakan; Başar, Cengiz; Gürlevik, Zehra; Alçelik, Ayşegül
2012-11-01
In-stent restenosis (ISR) is the major limitation of percutaneous coronary stenting procedure. The elements like nickel, chromate and molybdenum are known to cause contact allergy. Hypersensitivity reaction, against these metal ions, may be one of the reasons of ISR. Cobalt chromium coronary stents, which are increasingly being used in percutaneous coronary interventions, have more nickel amount than the stainless steel stents. We aimed to investigate the association between nickel hypersensitivity reaction and ISR in patients treated with cobalt chromium coronary stents. Epicutaneous patch tests for nickel were applied to 31 patients who had undergone elective cobalt chromium coronary stent implantation and had ISR in control angiogram. Thirty patients, without ISR, were included as the control group. Patch test results and other clinical variables were compared. There was no statistically significant difference of the mean age, sex, body mass index, rate of hypercholesterolemia, diabetes, hypertension and smoking between the patients with and without ISR. All other lesion characteristics were similar in the 2 groups. According to the patch test results, 7 patients had nickel contact allergy. All of these patients were in the ISR group, which was statistically significant (p<0.006). Patients treated with cobalt chromium coronary stents and had ISR were found to have significantly more nickel allergy than the control group. Nickel allergy may play role in restenosis pathophysiology.
von Spiczak, Jochen; Mannil, Manoj; Peters, Benjamin; Hickethier, Tilman; Baer, Matthias; Henning, André; Schmidt, Bernhard; Flohr, Thomas; Manka, Robert; Maintz, David; Alkadhi, Hatem
2018-05-23
The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 × 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I463). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q703) and level 5 (Q705) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's γ and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Interreader and intrareader reliability were excellent (γ = 0.953, ICCs = 0.891-0.999, and γ = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 ± 0.5 vs D70: 2.9 ± 0.3; P < 0.001), in-stent diameter difference (1.5 ± 0.3 vs 1.0 ± 0.3 mm; P < 0.001), and image sharpness (728 ± 246 vs 2069 ± 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 ± 76 vs 158 ± 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 ± 1, D70: 111 ± 3, Q703: 65 ± 2, Q705: 46 ± 2 CT numbers; P < 0.001 for all comparisons). A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.
Holmes, D R; Lansky, A; Kuntz, R; Bell, M R; Buchbinder, M; Fortuna, R; O'Shaughnessy, C D; Popma, J
2000-11-15
A new martensitic nitinol stent with improved flexibility and radiopacity was tested to evaluate whether these differences improve initial or long-term outcome. Patients who underwent percutaneous revascularization of a discrete native coronary lesion were randomly assigned to the new stent (PARAGON, n = 349) or to the first-generation Palmaz-Schatz (PS) stent (n = 339). The primary end point was target vessel failure at 6 months (a composite of cardiac or noncardiac death, any infarction in the distribution of the treated vessel, or clinically indicated target vessel revascularization). Secondary end points were, among others, device and procedural success and angiographic restenosis. Mean age was 62 years; diabetes was present in 21% of patients, prior bypass surgery in 6%, and recent infarction in 22% (p = NS for comparison between the 2 randomized arms). The PARAGON stent group had smaller reference vessels (2.97 vs 3.05 mm, p = 0.05), more prior restenosis (8.0% vs 4.5%, p = 0.07), and a longer average stent length (21.3 vs 19.4 mm, p < 0.05). Device success was significantly higher in the PARAGON arm (99.1% vs 94.3%, p < 0.05). Death and infarction at 6-month follow-up were infrequent in both groups. There was no significant difference in death (2.0% vs 1.2%, p = 0.546), but a higher rate of infarction for the PARAGON cohort (9.2% vs 4.7%, p = 0.025). Although target vessel failure (20.3% vs 12.4%, p = 0.005) and target lesion revascularization (12.0% vs 5.9%, p = 0.005) were higher in the PARAGON group, there was no significant difference in 6-month follow-up in in-stent minimal lumen diameter or in the rate of binary angiographic restenosis. Both PARAGON and PS stents are safe and associated with infrequent adverse events. The PARAGON stent can be delivered more frequently than the first-generation PS stent. Although there was no significant difference in in-stent minimal lumen diameter or the frequency of angiographic restenosis, clinical restenosis was more frequent in the PARAGON group.
Myocardial infarction and subsequent death in a patient undergoing robotic prostatectomy.
Thompson, Judy
2009-10-01
A 52-year-old patient, ASA physical status IV, undergoing a radical prostatectomy for cancer with a robotic system had a cardiac arrest 3 hours into the case. All attempts to resuscitate were unsuccessful, and several hours later he was pronounced dead. Underlying patient comorbidity and procedural issues contributed to the patient's death. The patient had a history of coronary artery disease that required the placement of drug-eluting stents 2 years before this surgical procedure. The preoperative cardiac evaluation and pharmacological management of patients with drug-eluting coronary stents are reviewed. There are a number of positional and technical considerations for patients undergoing robotic surgical procedures, especially in relation to the requirement of low-lithotomy and steep Trendelenburg positions. The cardiac and respiratory systems are especially vulnerable to the extreme and lengthy head-down position. The needed positioning, combined with the problems associated with insufflation, presents a unique challenge in anesthetic management. This course reviews the current literature on the surgical implications for patients with drug-eluting stents and the physiologic factors related to position and pneumoperitoneum and their associated stressors. By using a review of the contemporary literature, a best-evidence approach to anesthetic management is reviewed.
Ali, Ziad A; Maehara, Akiko; Généreux, Philippe; Shlofmitz, Richard A; Fabbiocchi, Franco; Nazif, Tamim M; Guagliumi, Giulio; Meraj, Perwaiz M; Alfonso, Fernando; Samady, Habib; Akasaka, Takashi; Carlson, Eric B; Leesar, Massoud A; Matsumura, Mitsuaki; Ozan, Melek Ozgu; Mintz, Gary S; Ben-Yehuda, Ori; Stone, Gregg W
2016-11-26
Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm 2 ), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586. Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm 2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm 2 (4·67-7·80) with IVUS guidance, and 5·49 mm 2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm 2 ; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37). OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance. St Jude Medical. Copyright © 2016 Elsevier Ltd. All rights reserved.
[Myocardial ischemia in general medicine and the revolution of coronary stents].
El-Mourad, M; Merveille, P; Preumont, N
2014-09-01
Since Gruentizg's first percutaneous transluminal ballon angioplasty in 1977 in Zurich, percuta. neous coronary intervention evolved significantly in order to overcome the numerous associated complications of each technique. Bare-metal stents (BMS) made their initial appearance followed by three generations of drug-eluting stents (DES). The use of bioabsorbable vascular scaffold stents (BVS) has become more frequent creating a temporary scaffold allowing healing of the endothelium within 2 years. In this article, we discuss the nomenclature of the main intravascular complications linked to percuta. neous coronary intervention such as stent thrombosis (ST), Instent restenosis (ISR), neoatherosclerosis, and stents evolution to overcome these complications. We will finally mention the new technologies of intracoronary imaging such as OCT (Optical Coherence Tomography) having an increasing vital role in percutaneous coronary intervention,
Computational high-resolution heart phantoms for medical imaging and dosimetry simulations
NASA Astrophysics Data System (ADS)
Gu, Songxiang; Gupta, Rajiv; Kyprianou, Iacovos
2011-09-01
Cardiovascular disease in general and coronary artery disease (CAD) in particular, are the leading cause of death worldwide. They are principally diagnosed using either invasive percutaneous transluminal coronary angiograms or non-invasive computed tomography angiograms (CTA). Minimally invasive therapies for CAD such as angioplasty and stenting are rendered under fluoroscopic guidance. Both invasive and non-invasive imaging modalities employ ionizing radiation and there is concern for deterministic and stochastic effects of radiation. Accurate simulation to optimize image quality with minimal radiation dose requires detailed, gender-specific anthropomorphic phantoms with anatomically correct heart and associated vasculature. Such phantoms are currently unavailable. This paper describes an open source heart phantom development platform based on a graphical user interface. Using this platform, we have developed seven high-resolution cardiac/coronary artery phantoms for imaging and dosimetry from seven high-quality CTA datasets. To extract a phantom from a coronary CTA, the relationship between the intensity distribution of the myocardium, the ventricles and the coronary arteries is identified via histogram analysis of the CTA images. By further refining the segmentation using anatomy-specific criteria such as vesselness, connectivity criteria required by the coronary tree and image operations such as active contours, we are able to capture excellent detail within our phantoms. For example, in one of the female heart phantoms, as many as 100 coronary artery branches could be identified. Triangular meshes are fitted to segmented high-resolution CTA data. We have also developed a visualization tool for adding stenotic lesions to the coronaries. The male and female heart phantoms generated so far have been cross-registered and entered in the mesh-based Virtual Family of phantoms with matched age/gender information. Any phantom in this family, along with user-defined stenoses, can be used to obtain clinically realistic projection images with the Monte Carlo code penMesh for optimizing imaging and dosimetry.
Sung, Pei-Hsun; Lee, Fan-Yen; Tong, Meng-Shen; Chiang, John Y; Pei, Sung-Nan; Ma, Ming-Chun; Li, Yi-Chen; Chen, Yung-Lung; Wu, Chiung-Jen; Sheu, Jiunn-Jye; Lee, Mel S; Yip, Hon-Kan
2018-05-01
This study investigated the clinical and angiographic long-term outcomes of intracoronary transfusion of circulation-derived CD34+ cells for patients with end-stage diffuse coronary artery disease unsuitable for coronary intervention. A single-center prospective randomized double-blinded phase I clinical trial. Thirty-eight patients undergoing CD34+ cell therapy were allocated into groups 1 (1.0 × 10 cells/each vessel; n = 18) and 2 (3.0 × 10 cells/each vessel; n = 20). Those with end-stage diffuse coronary artery disease were unsuitable for percutaneous and surgical coronary revascularization. Intracoronary delivery of circulation-derived CD34+ cells. We prospectively evaluated long-term clinical and echocardiographic/angiographic outcomes between survivors and nonsurvivors. By the end of 5-year follow-up, the survival rate and major adverse cardio/cerebrovascular event were 78.9% (30/38) and 36.8% (14/38), respectively. During follow-up period, 31.6% patients (12/38) received coronary stenting for reason of sufficient target vessel size grown-up after the treatment. Endothelial function was significantly reduced in the nonsurvivors than the survivors (p = 0.039). Wimasis image analysis of angiographic findings showed that the angiogenesis was significantly and progressively increased from baseline to 1 and 5 years (all p < 0.001). The 3D echocardiography showed left ventricular ejection fraction increased from baseline to 1 year and then remained stable up to 5 years, whereas left ventricular chamber diameter exhibited an opposite pattern to left ventricular ejection fraction among the survivors. The clinical scores for angina and heart failure were significantly progressively reduced from baseline to 1 and 5 years (all p < 0.001). CD34+ cell therapy for end-stage diffuse coronary artery disease patients might contribute to persistently long-term effects on improvement of left ventricular function, angina/heart failure, and amelioration of left ventricular remodeling.
Jaberg, Laurenz; Toggweiler, Stefan; Puck, Marietta; Frank, Michelle; Rufibach, Kaspar; Lüscher, Thomas F; Corti, Roberto
2011-01-01
Patients undergoing acute left main (LM) coronary artery revascularization have a high mortality and natriuretic peptides such as N-terminal pro-B-type (NT-proBNP) have been shown to have prognostic value in patients with acute coronary syndromes. The present study looked at the prognostic value of NT-proBNP in these patients. We studied all consecutive patients undergoing acute LM coronary artery percutaneous coronary intervention between January 2005 and December 2008 in whom NT-proBNP was measured (n=71). We analyzed the clinical characteristics and the short- and long-term outcomes in relation to NT-proBNP level at admission. Median NT-proBNP was 1,364 ng/L, ranging from 46 to 70,000 ng/L. NT-proBNP was elevated in 63 (89%) patients and was ≥1,000ng/L in 42 (59%). Log NT-proBNP (hazard ratio [HR] 3.51, 95% confidence interval [CI] 1.55-7.97, P=0.003) and left ventricular ejection fraction (HR 0.95, 95%CI 0.91-0.99, P=0.007) were predictors for all-cause mortality. Log NT-proBNP was the only independent significant predictor of cardiovascular mortality. In-hospital mortality was 0% for patients with NT-proBNP <1,000, but 17% for those with NT-proBNP ≥1,000 (P=0.036). NT-proBNP is a strong predictor of outcome in patients undergoing acute LM coronary artery stenting. Mortality in such patients is high, but those with NT-proBNP < 1,000ng/L may have a favorable short- and long-term prognosis. Further research, including a larger patient population, is needed to determine the optimal cut-off value for NT-proBNP in patients undergoing acute LM coronary artery intervention.
Holmvang, Lene; Kelbæk, Henning; Kaltoft, Anne; Thuesen, Leif; Lassen, Jens Flensted; Clemmensen, Peter; Kløvgaard, Lene; Engstrøm, Thomas; Bøtker, Hans E; Saunamäki, Kari; Krusell, Lars R; Jørgensen, Erik; Tilsted, Hans-Henrik; Christiansen, Evald H; Ravkilde, Jan; Køber, Lars; Kofoed, Klaus Fuglsang; Terkelsen, Christian J; Helqvist, Steffen
2013-06-01
This study sought to compare the long-term effects of drug-eluting stent (DES) compared with bare-metal stent (BMS) implantation in patients with ST-segment elevation myocardial infarction (STEMI) undergoing primary percutaneous coronary intervention. The randomized DEDICATION (Drug Elution and Distal Protection in Acute Myocardial Infarction) trial evaluated the outcome after DES compared with BMS implantation in patients with STEMI undergoing primary percutaneous coronary intervention. Patients with a high-grade stenosis/occlusion of a native coronary artery presenting with symptoms <12 h and ST-segment elevation were enrolled after giving informed consent. Patients were randomly assigned to receive a DES or a BMS in the infarct-related lesion. Patients were followed for at least 5 years, and clinical endpoints were evaluated from population registries and hospital charts. The main endpoint was the occurrence of the first major adverse cardiac event (MACE), defined as cardiac death, nonfatal recurrent myocardial infarction, and target lesion revascularization. Complete clinical status was available in 623 patients (99.5%) at 5 years follow-up. The combined MACE rate was insignificantly lower in the DES group (16.9% vs. 23%), mainly driven by a lower need of repeat revascularization (p = 0.07). Whereas the number of deaths from all causes tended to be higher in the DES group (16.3% vs. 12.1%, p = 0.17), cardiac mortality was significantly higher (7.7% vs. 3.2%, p = 0.02). The 5-year stent thrombosis rates were generally low and similar between the DES and the BMS groups. No cardiac deaths occurring within 1 month could be clearly ascribed to stent thrombosis, whereas stent thrombosis was involved in 78% of later-occurring deaths. The 5-year MACE rate was insignificantly different, but the cardiac mortality was higher after DES versus BMS implantation in patients with STEMI. Stent thrombosis was the main cause of late cardiac deaths. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
A rare complication with remarkable stent shortening and successful recovery from the trouble.
Goto, Yoshitaka; Kawasaki, Tomohiro; Koga, Hisashi
2012-05-01
Deployed coronary stent distortion is a rare complication, but can potentially occur during coronary intervention. We herein report a rare complicated case with remarkable stent distortion of longitudinal stent shortening and successful recovery from a trouble using a Corsair microcatheter.
Illuminati, G; Ricco, J-B; Greco, C; Mangieri, E; Calio', F; Ceccanei, G; Pacilè, M A; Schiariti, M; Tanzilli, G; Barillà, F; Paravati, V; Mazzesi, G; Miraldi, F; Tritapepe, L
2010-02-01
To evaluate the usefulness of systematic coronary angiography followed, if needed, by coronary artery angioplasty (percutaneous coronary intervention (PCI)) on the incidence of cardiac ischaemic events after carotid endarterectomy (CEA) in patients without evidence of coronary artery disease (CAD). From January 2005 to December 2008, 426 patients, candidates for CEA, with no history of CAD and with normal cardiac ultrasound and electrocardiography (ECG), were randomised into two groups. In group A (n=216) all the patients had coronary angiography performed before CEA. In group B, all the patients had CEA without previous coronary angiography. In group A, 66 patients presenting significant coronary artery lesions at angiography received PCI before CEA. They subsequently underwent surgery under aspirin (100 mg day(-1)) and clopidogrel (75 mg day(-1)). CEA was performed within a median delay of 4 days after PCI (range: 1-8 days). Risk factors, indications for CEA and surgical techniques were comparable in both groups (p>0.05). The primary combined endpoint of the study was the incidence of postoperative myocardial ischaemic events combined with the incidence of complications of coronary angiography. Secondary endpoints were death and stroke rates after CEA and incidence of cervical haematoma. Postoperative mortality was 0% in group A and 0.9% in group B (p=0.24). One postoperative stroke (0.5%) occurred in group A, and two (0.9%) in group B (p=0.62). No postoperative myocardial event was observed in group A, whereas nine ischaemic events were observed in group B, including one fatal myocardial infarction (p=0.01). Binary logistic regression analysis demonstrated that preoperative coronary angiography was the only independent variable that predicted the occurrence of postoperative coronary ischaemia after CEA. The odds ratio for coronary angiography (group A) indicated that when holding all other variables constant, a patient having preoperative coronary angiography before carotid surgery was 4 times less likely to have a cardiac ischaemic event after carotid surgery. No complications related to coronary angiography were observed and no cervical haematomas occurred in patients undergoing surgery under aspirin and clopidogrel in this study. Systematic preoperative coronary angiography, possibly followed by PCI, significantly reduces the incidence of postoperative myocardial events after CEA in patients without clinical evidence of CAD. Copyright (c) 2009 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Treg/Th17 balance in stable CAD patients with different stages of coronary atherosclerosis.
Potekhina, Alexandra V; Pylaeva, Ekaterina; Provatorov, Sergey; Ruleva, Natalya; Masenko, Valery; Noeva, Elena; Krasnikova, Tatiana; Arefieva, Tatiana
2015-01-01
Objective. Immune processes play a significant role in atherosclerosis plaque progression. Regulatory T cells and T helpers 17 were shown to possess anti- and pro-atherogenic activity, respectively. We aimed to investigate the balance of circulating Treg and Th17 in stable angina patients with different stages of coronary atherosclerosis. Methods. Treg, Th17 and Th1 cell frequencies were studied in 117 patients via direct immunofluorescence staining and flow cytometry. Group 1 had intact coronary arteries. Group 2 and Group 3 had undergone previous coronary stenting; in Group 2 no coronary atherosclerosis progression was found, in Group 3 patients had disease progression in non-invaded coronary arteries. Group 4 had severe coronary atherosclerosis. Results. The frequencies of CD4+CD25highCD127low, CD4+foxp3+, and CD4+IL10 + T cells were decreased, and CD4+IL17 + T cells frequencies were increased in group 4 vs. 1. Treg/Th17 ratios were declined in groups 3 and 4 vs. groups 1 and 2. IL-10 level was lower while hsCRP and sCD25 levels were higher in group 4 vs. 1. Conclusion. We assume that the imbalance in pro- and anti-inflammatory/atherogenic lymphocyte subpopulations is associated with atherosclerosis progression. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Liu, Junfeng; Liu, Yunde; Jia, Kegang; Huo, Zhixiao; Huo, Qianyu; Liu, Zhili; Li, Yongshu; Han, Xuejing; Wang, Rong
2018-04-01
In-stent restenosis (ISR) is the most common complication associated with percutaneous coronary intervention (PCI). Although some studies have reported an association between lectin-like oxidized low-density lipoprotein receptor-1 (LOX-1) and ISR, not enough clinical validation data are available to support this link. Here, we report our cross-sectional study aimed at exploring the feasibility of LOX-1 as a biomarker for the prognostic diagnosis of patients undergoing PCI.Three groups were included: ISR group, including 99 patients with ISR diagnosed with coronary arteriography (CAG) after PCI; lesion group, comprising 87 patients with coronary artery stenosis (<50%) diagnosed with CAG after PCI; and control group, consisting of 96 volunteers with no coronary artery disease. The levels of LOX-1 were measured in each patient by using an enzyme-linked immunosorbent assay, and their general information as well as laboratory parameters were recorded and followed up during a period of 2 years.LOX-1 levels gradually increased after PCI along with the progression of the lesion in the 3 groups. The levels of LOX-1 were significantly higher in the ISR group than in the other 2 groups (P < .001). LOX-1 levels were correlated with the levels of uric acid (UA) (r = 0.289, P = .007), creatinine (CREA) (r = .316, P = .003), and high-density lipoprotein cholesterol (HDL-C) (r = -0.271, P = .012), whereas no statistically significant correlation was detected with the Gensini score (r = 0.157, P = .141). The sensitivity and specificity of LOX-1 were 81.5% and 55.7%, respectively, with the most optimal threshold (5.04 μg/L). The area under curve (AUC) of the receiver operator characteristic (ROC) curve of LOX-1 was 0.720, and LOX-1 had the highest AUC compared with CREA, UA, and HDL-C, both individually and in combination.A high level of LOX-1 in the early period after PCI has a certain predictive power and diagnostic value for ISR. However, the level of LOX-1 is not related to the Gensini score of coronary artery after PCI, and CREA and UA, which are weakly related to LOX-1, have no obvious synergy in the diagnosis of ISR with LOX-1.
Genetics of coronary artery disease and myocardial infarction
Dai, Xuming; Wiernek, Szymon; Evans, James P; Runge, Marschall S
2016-01-01
Atherosclerotic coronary artery disease (CAD) comprises a broad spectrum of clinical entities that include asymptomatic subclinical atherosclerosis and its clinical complications, such as angina pectoris, myocardial infarction (MI) and sudden cardiac death. CAD continues to be the leading cause of death in industrialized society. The long-recognized familial clustering of CAD suggests that genetics plays a central role in its development, with the heritability of CAD and MI estimated at approximately 50% to 60%. Understanding the genetic architecture of CAD and MI has proven to be difficult and costly due to the heterogeneity of clinical CAD and the underlying multi-decade complex pathophysiological processes that involve both genetic and environmental interactions. This review describes the clinical heterogeneity of CAD and MI to clarify the disease spectrum in genetic studies, provides a brief overview of the historical understanding and estimation of the heritability of CAD and MI, recounts major gene discoveries of potential causal mutations in familial CAD and MI, summarizes CAD and MI-associated genetic variants identified using candidate gene approaches and genome-wide association studies (GWAS), and summarizes the current status of the construction and validations of genetic risk scores for lifetime risk prediction and guidance for preventive strategies. Potential protective genetic factors against the development of CAD and MI are also discussed. Finally, GWAS have identified multiple genetic factors associated with an increased risk of in-stent restenosis following stent placement for obstructive CAD. This review will also address genetic factors associated with in-stent restenosis, which may ultimately guide clinical decision-making regarding revascularization strategies for patients with CAD and MI. PMID:26839654
Impact of lesion characteristics on the prediction of optimal poststent fractional flow reserve.
Ando, Hirohiko; Takashima, Hiroaki; Suzuki, Akihiro; Sakurai, Shinichiro; Kumagai, Soichiro; Kurita, Akiyoshi; Waseda, Katsuhisa; Amano, Tetsuya
2016-12-01
Poststent fractional flow reserve (FFR) is a useful indicator of optimal percutaneous coronary intervention, and higher poststent FFR is associated with favorable long-term clinical outcome. However, little is known about the factors influencing poststent FFR. The purpose of this study was to determine the impact of lesion characteristics on poststent FFR. For patients who had scheduled stent implantation for stable angina, FFR measurements at maximum hyperemia were performed before and after coronary stent implantation. As one of lesion characteristics, the FFR pressure drop pattern was evaluated and classified as either an abrupt or a gradual pattern according to the pullback curve of FFR. A total of 205 lesions with physiological significant stenosis were evaluated. Fractional flow reserve value increased from 0.67±0.10 to 0.87±0.07 after stent implantation. Optimal poststent FFR was achieved in 75 lesions (36.6%). Logistic regression analysis demonstrated that optimal poststent FFR was positively correlated with an abrupt pressure drop pattern (hazard ratio [HR] 2.11, 95% CI 1.06-4.15, P=.03) and prestent FFR (HR 1.04, 95% CI 1.03-2.04, P=.03; per 0.1 increase), and negatively correlated with lesion localization to the left anterior descending artery (HR 0.18, 95% CI 0.09-0.36, P<.0001). The c statistic for predicting optimal poststent FFR was 0.763 (95% CI 0.702-0.819). Abrupt pressure drop patterns, prestent FFR, and lesion localization to the left anterior descending artery were independent predictors of optimal poststent FFR. Copyright © 2016 Elsevier Inc. All rights reserved.
Chua, Su-Kiat; Hung, Huei-Fong
2009-07-01
A 73-year-old man with resistant hypertension and impaired renal function underwent stenting for right renal artery (RRA) stenosis. Two years later, he presented with uncontrolled hypertension and worse renal function. Renal arteriogram revealed RRA stent fracture with in-stent restenosis. Another stent was deployed. Four months later, however, renal arteriogram revealed in-stent restenosis again. This time, balloon angioplasty alone was performed. He had been symptom-free with stable condition at 2-year follow-up. A literature review disclosed six renal artery stent fracture cases, including the present one, who developed in-stent stenosis resulted from stent fracture. Two major anatomy features of renal artery stenosis were suggestive for development of stent fracture: (1) renal artery entrapment by diaphragmatic crus, and (2) mobile kidney with acute angulation at proximal segment of the renal artery. It is important to detect this etiology of renal artery stenosis because stenting in these vessels may contribute to in-stent restenosis or stent fracture. Management of renal artery stent fracture, including endovascular treatment or aortorenal bypass, should be considered on a case-by-case basis in relation to clinical settings. Copyright 2009 Wiley-Liss, Inc.
A review on fracture prevention of stent in femoropopliteal artery
NASA Astrophysics Data System (ADS)
Atan, Bainun Akmal Mohd; Ismail, Al Emran; Taib, Ishkrizat; Lazim, Zulfaqih
2017-01-01
Heavily calcific lesions, total occlusions, tortuous blood vessels, variable lengths of arteries, various dynamic loads and deformations in the femoropopliteal (FP) arterial segment make stenosis treatments are complicated. The dynamic forces in FP artery including bending, torsion and radial compression may lead to stent fracture (SF) and eventually to in-stent restenosis (ISR). Stent design specifically geometrical configurations are a major factor need to be improved to optimize stent expansion and flexibility both bending and torsion during stent deployment into the diseased FP artery. Previous studies discovered the influence of various stent geometrical designs resulted different structural behaviour. Optimizing stent design can improve stent performances: flexibility and radial strength to prevent SF in FP arterial segment
Martínez-Quintana, Efrén; Rodríguez-González, Fayna; Medina-Gil, José María; Garay-Sánchez, Paloma; Tugores, Antonio
Paraoxonase 1 (PON1) plays a major role in the oxidation of low density lipoprotein and in the prevention of coronary atherogenesis. In this context, coding region polymorphisms of PON1 gene, responsible for the enzyme activity, has become of interest as a marker for atherogenesis. A study and follow-up was conducted on 529 patients with an acute coronary event in order to assess the association between the PON1 Q192R (rs662;A/G) polymorphism, the type of acute coronary syndrome, cardiovascular risk factors (arterial hypertension, diabetes mellitus, dyslipidaemia, and smoking), the extent and severity of coronary atherosclerosis, and the medium-term clinical follow-up. The QQ genotype was found in 245 (46.3%) patients, with 218 (41.2%) patients showing the QR genotype, and 66 (14.5%) patients had the RR genotype. No significant differences were found between the QQ and QR/RR genotypes as regards the clinical characteristics, the analytical data, and the angiographic variables. Similarly, Kaplan-Meier survival analysis showed no significant differences in presenting with a new acute coronary event (p=0.598), cardiac mortality (p=0.701), stent thrombosis (p=0.508), or stent re-stenosis (p=0.598) between QQ and QR/RR genotypes during the follow-up period (3.3±2.2 years). In patients with an acute coronary syndrome, the PON1 Q192R genotypes did not influence the risk of suffering a new acute coronary event during the medium-term follow-up. Copyright © 2016 Sociedad Española de Arteriosclerosis. Publicado por Elsevier España, S.L.U. All rights reserved.
Mahapatro, Anil; Johnson, Dave M; Patel, Devang N; Feldman, Marc D; Ayon, Arturo A; Agrawal, C Mauli
2006-09-01
The use of self-assembled monolayers (SAMs) on medical devices offers a methodology for the incorporation of nanotechnology into medicine. SAMs are highly ordered nanosized molecular coatings, adding 1 to 10 nm thickness to a surface. This work is part of an overall goal to deliver therapeutic drugs from the surface of metal coronary stents using SAMs. In this study the oxidative and in vitro stability of functional alkylthiol SAMs on 316L stainless steel (SS) has been demonstrated. SAMs of 11-mercaptoundecanoic acid (-COOH SAM) and 11-mercapto-1-undecanol (-OH SAM) were formed on 316L SS. X-ray photoelectron spectroscopy (XPS), Fourier transform infrared spectroscopy (FTIR), and contact angle (CA) measurements collectively confirmed the formation of functional alkylthiol SAMs on 316L SS. Well-formed SAMs (CA: 82 deg +/- 9 deg) were achieved within 48 hours of immersion in ethanolic solutions, after which no significant improvement in CA was observed. The ratio of the thiolate peak (163.5 eV) to the oxidized sulfur (sulfonates) peak (166.5 eV) gives us an indication of the percentage SAMs that would bind to the metal and serve as a drug reservoir in vivo; which in turn represents the stability and viability of these SAMs, keeping in mind the cardiovascular application under consideration. Oxidative and in vitro stability studies showed that alkanethiol SAMs oxidized completely within 14 days. The SAMs tend to desorb and leave the metal surface after longer time periods (21 days) in phosphate-buffered saline (PBS) immersion, whereas for oxidative exposure the SAMs continue to remain on the metal surface in the form of sulfonates. Although the chemistry of bonding of alkylthiol with the 316L SS is not well understood, the nanosized alkylthiol SAMs demonstrate sufficient stability to justify further study on these systems for potential in vivo drug delivery in the chosen coronary artery stent applications.
Financial impact of coronary stenting in emergency for acute coronary syndromes.
Nidegger, Delphine; Metz, Damien; Vacter, Christophe; Tassan-Mangina, Sophie; Deschildre, Alain; Gawron, Michel; Bourgeois, Jacqueline
2009-05-01
Since the prospective payment system, health institutions have only specific payments for the emergency care in the emergency room. The direct urgent admissions in coronary care units for acute coronary syndrome (ACS) do not collect this complementary refund. For the patient's stay, hospital is remunerated with fixed national prices which are similar even in case of emergent or planed coronary revascularization when realized. To analyze and compare the financial impact between emergent and planed coronary stenting in the setting of ACS. This retrospective study was based on patients suffering from ACS who experienced emergent coronary stenting during the year 2005. On 154 patients, 127 were age-, sex- and diagnosis-related group (called "groupe homogène de malades" in the French Health Care system)-matched with 127 suffering from same ACS but with planed "ad hoc" coronary stenting. The overall charges (medical and paramedical team, pharmacy, biology, implantable coronary devices, radiology) were compared between the two groups. Mean stay duration was 6.7 days and did not differ between the two groups. Mean financial retributions were significantly higher in the emergent group (7338 euro [6831-7846] IC95 vs 6509 euro [5994-7023]; p=0,02) but with a much more raised consumption (6810 euro [6283-7336] vs 5223 euro [4632-5814]; p=0,001). This overcost was due especially to drugs and biological expenses. The hospitalization payments did not cover the overall expenses for 25% of the patients' stays (N=64) among whom 39 have had emergent coronary stenting (30.7%, p=0.04). Among the different GHM, the most important difference was observed in non-STEMI without complication with a negative receipts/costs ratio for 37.8% of the stay with coronary stenting in emergency. The application of the recent guidelines for coronary revascularization in the management of ACS represents a financial venture for hospital institutions. The engaged charges for emergent coronary stenting are covered with difficulties contrary to planed revascularization.
Weber, Frank D; Schneider, Henrik; Wiemer, Marcus; Pfannebecker, Thomas; Tebbe, Ulrich; Hamm, Christian W; Senges, Jochen; Schneider, Steffen; Nienaber, Christoph A
2008-02-01
Patients with diabetes mellitus (DM) undergoing percutaneous coronary intervention (PCI) are at increased risk for adverse outcomes. The use of sirolimus eluting stents (SES) has been shown to improve outcomes in diabetic patients. Since results from randomized trials were derived from selected patients scientific scrutiny under real world conditions is necessary. 1,948 patients with DM and 4,707 patients without DM were included in the German Cypher Registry, a post-marketing survey of use of SES in Germany. In >99% of entry cases a structured clinical follow-up was completed. By angiographic criteria severity of coronary artery disease was higher in diabetic patients compared to non-diabetics. However, procedural success and in-hospital complication rates were comparable between DM- and non-DM-patients. 6 months MACE rate in the DM group was significantly higher than in the non-DM group (16.4% vs. 13.0%) but lower than expected from historical data with the use of bare metal stents (BMS). The results with SES in diabetics are encouraging but DM remains a risk factor for poor outcome of PCI. No statement is justified whether the treatment of diabetics with SES is at least as safe as bypass surgery. This intriguing question has to be answered in a direct randomized head-to-head comparison with state of the art surgery.
Trehan, Vijay K.; Jain, Gagan; Kathuria, Sanjeev; Pandit, Bhagya N.
2013-01-01
Stent dislodgment during percutaneous coronary intervention is a rare complication. We report a case of successful retrieval of a deformed coronary stent through alternative transfemoral approach while performing transradial procedure when the stent could not be retrieved safely from transradial route. PMID:23809390
Sardella, Gennaro; Stefanini, Giulio G; Briguori, Carlo; Tamburino, Corrado; Fabbiocchi, Franco; Rotolo, Francesco; Tomai, Fabrizio; Paggi, Anita; Lombardi, Mario; Gioffrè, Gaetano; Sclafani, Rocco; Rolandi, Andrea; Sciahbasi, Alessandro; Scardaci, Francesco; Signore, Nicola; Calcagno, Simone; Mancone, Massimo; Chiarito, Mauro; Giordano, Arturo
2018-05-21
Polymer-free biolimus-eluting stents (PF-BES) have been shown superior to bare metal stents in high bleeding risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT). However, limited evidence is available on PF-BES in non-HBR patients. We aim to evaluate the safety and efficacy of PF-BES in all-comer patients undergoing percutaneous coronary interventions (PCI). Patients with stable coronary artery disease or acute coronary syndromes (ACS) undergoing PCI with PF-BES in routine clinical practice were included in a multicenter, prospective registry. DAPT duration was left at the discretion of the operator. The primary endpoint was the composite of cardiovascular death, myocardial infarction (MI), and definite/probable stent thrombosis (ST) at 1 year. Overall, 1,104 consecutive patients treated with PF-BES were included at 16 Italian centers. Mean age was 68.7±11.2 years, 77.2% of patients were men, 30% had diabetes, 15.1% had chronic kidney disease, and 40.5% had ACS at baseline. Mean CRUSADE score was 24.1±13.1, and 83.7% of patients did not have high bleeding risk features. At 1-year, the primary endpoint occurred in 4.1% of patients, cardiovascular death in 2.4%, MI in 1.8%, and definite/probable ST in 1.1%. With respect to efficacy, target-lesion revascularization occurred in 1.2% of patients. This is the first study providing clinical evidence on the use of PF-BES in all-comer patients irrespective of HBR status. Our findings suggest that PF-BES has a favorable safety and efficacy profile in a real world clinical setting. Further investigation in randomised clinical trials against new-generation DES is warranted.
Krucoff, Mitchell W; Rutledge, David R; Gruberg, Luis; Jonnavithula, Lalitha; Katopodis, John N; Lombardi, William; Mao, Vivian W; Sharma, Samin K; Simonton, Charles A; Tamboli, Hoshedar P; Wang, Jin; Wilburn, Olivia; Zhao, Weiying; Sudhir, Krishnankutty; Hermiller, James B
2011-12-01
The XIENCE V USA (XIENCE V Everolimus Eluting Coronary Stent System Condition-of-Approval Post-Market study) sought to: 1) evaluate the safety of everolimus-eluting coronary stent systems (EECSS) in a contemporary cohort of real-world subjects; and 2) prospectively test the quality of event reporting with analysis of matched patients from the randomized SPIRIT IV (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions) trial. Randomized trials have demonstrated the safety and efficacy of EECSS in selected "standard-risk" patients. The XIENCE V USA trial was a prospective, multicenter, single-arm study in unselected patients. The primary endpoint was Academic Research Consortium (ARC)-defined definite and probable stent thrombosis (ST); the co-primary endpoint was the composite of cardiac death and myocardial infarction at 1 year. Secondary analyses included: 1) stratification by standard-risk and extended-risk cohorts; and 2) late ST after dual antiplatelet therapy interruption. Of 5,054 participants (1,875 standard-risk; 3,179 extended-risk), 4,958 (98.1%) reached 1-year follow-up. The rate of ARC-defined definite and probable ST was 0.84% (95% confidence interval [CI]: 0.60% to 1.14%) in the overall population and 0.33% (95% CI: 0.12% to 10.72%) and 1.14% (95% CI: 0.80% to 11.58%) in the standard-risk and extended-risk cohorts, respectively. No late ST was observed after dual antiplatelet therapy interruption in either cohort after 6 months. The composite rate of cardiac death and ARC-defined myocardial infarction was 6.5% (95% CI: 5.79% to 17.17%) in the overall population, 3.8% (95% CI: 2.98% to 14.78%) in the standard-risk cohort, and 8.0% (95% CI: 7.09% to 19.02%) in the extended-risk cohort. This study comprehensively reports ST rates for EECSS in a contemporary real-world population. The absence of ST after dual antiplatelet therapy interruption beyond 6 months in standard-risk and high-risk patients is notable. Consistent safety outcomes between matched standard-risk cohorts from the XIENCE V USA study and the SPIRIT IV randomized trial suggest that this study affords a reliable benchmark for understanding the safety of EECSS in the context of real-world clinical practice. (XIENCE V Everolimus Eluting Coronary Stent System [EECSS] USA Post-Approval Study; NCT00676520). Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Anti-Inflammatory Effect of Gallic Acid-Eluting Stent in a Porcine Coronary Restenosis Model
Seob Lim, Kyung; Park, Jun-Kyu; Ho Jeong, Myung; Ho Bae, In; Sung Park, Dae; Won Shim, Jae; Ha Kim, Jung; Kuk Kim, Hyun; Soo Kim, Sung; Sun Sim, Doo; Joon Hong, Young; Han Kim, Ju; Ahn, Youngkeun
2018-01-01
Background Gallic acid (3,4,5-trihydroxybenzoic acid) is a natural polyphenol and strong natural antioxidant found abundantly in red wine and green tea. The aim of this study was to examine the anti-inflammatory effect of a novel gallic acid-eluting stent in a porcine coronary restenosis model. Methods Fifteen pigs were randomized into three groups; in which a total of 30 coronary arteries (10 in each group) were implanted with gallic acid-eluting stents (GESs, n = 10), gallic acid and sirolimus-eluting stents (GSESs, n = 10), or sirolimus-eluting stents (SESs, n = 10). Histopathologic analysis was performed 28 days after stenting. Results There were no significant differences in injury score and fibrin score among the groups, however there were significant differences in the internal elastic lamina (4.0 ± 0.83 mm2 in GES vs. 3.0 ± 0.53 mm2 in GSES vs. 4.6 ± 1.43 mm2 in SES, p < 0.0001), lumen area (2.3 ± 0.49 mm2 in GES vs. 1.9 ± 0.67 mm2 in GSES vs. 2.9 ± 0.56 mm2 in SES, p < 0.0001), neointimal area (1.7 ± 0.63 mm2 in GES vs. 1.1 ± 0.28 mm2 in GSES vs. 1.7 ± 1.17 mm2 in SES, p < 0.05), and percent area of stenosis (42.4% ± 9.22% in GES vs. 38.2% ± 12.77% in GSES vs. 33.9% ± 15.64% in SES, p < 0.05). The inflammation score was significantly lower in the GES and GSES groups compared to that in the SES group [1.0 (range: 1.0 to 2.0) in GES vs. 1.0 (range: 1.0 to 1.0) in GSES vs. 1.5 (range: 1.0 to 3.0) in SES, p < 0.05]. Conclusions The GES group had a greater percent area of stenosis than the SES group. Although gallic acid in the GES and GSES groups did not show a synergistic effect in suppressing neointimal hyperplasia, it resulted in greater inhibition of the inflammatory reaction in the porcine coronary restenosis model than in the SES group. PMID:29844643
Stone, Gregg W; Teirstein, Paul S; Meredith, Ian T; Farah, Bruno; Dubois, Christophe L; Feldman, Robert L; Dens, Joseph; Hagiwara, Nobuhisa; Allocco, Dominic J; Dawkins, Keith D
2011-04-19
We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI). Randomized trials have demonstrated an excellent safety and efficacy profile for the CoCr-EES. The PtCr-EES uses the identical antiproliferative agent and polymer but with a novel platinum chromium scaffold designed for enhanced deliverability, vessel conformability, side-branch access, radiopacity, radial strength, and fracture resistance. A total of 1,530 patients undergoing PCI of 1 or 2 de novo native lesions were randomized at 132 worldwide sites to CoCr-EES (n = 762) or PtCr-EES (n = 768). The primary endpoint was the 12-month rate of target lesion failure (TLF), the composite of target vessel-related cardiac death, target vessel-related myocardial infarction (MI), or ischemia-driven target lesion revascularization (TLR) in the per-protocol population (patients who received ≥1 assigned study stent), powered for noninferiority. The 12-month rate of TLF in the per-protocol population occurred in 2.9% versus 3.4% of patients assigned to CoCr-EES versus PtCr-EES, respectively (difference: 0.5%, 95% confidence interval: -1.3% to 2.3%, p(noninferiority) = 0.001, p(superiority) = 0.60). By intention-to-treat, there were no significant differences between CoCr-EES and PtCr-EES in the 12-month rates of TLF (3.2% vs. 3.5%, p = 0.72), cardiac death or MI (2.5% vs. 2.0%, p = 0.56), TLR (1.9% vs. 1.9%, p = 0.96), or Academic Research Consortium definite or probable stent thrombosis (0.4% vs. 0.4%, p = 1.00). In this large-scale, prospective, single-blind randomized trial, a novel PtCr-EES was noninferior to the predicate CoCr-EES for TLF, with nonsignificant differences in measures of safety and efficacy through 12-month follow-up after PCI. Copyright © 2011 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Meditations on secondary revascularisation in the aftermath of the SYNTAX trial.
Garg, Scot; Serruys, Patrick W
2009-05-01
Many patients will experience a return of symptoms after their initial revascularisation procedure necessitating secondary revascularisation (SR). The options for this second procedure are inherently influenced by the primary method adopted for revascularisation. Patients with single vessel disease are most suited to percutaneous coronary intervention (PCI) for both primary and secondary revascularisation. The arrival of drug eluting stents, and evidence from trials of highly select populations has threatened the place of coronary artery bypass grafting (CABG) as the preferred method of revascularisation in those with multivessel disease. At present, and without robust evidence, PCI is increasingly being used to treat highly complex lesions, such that many question whether CABG is still has a role in primary revascularisation. The consequence for SR is that currently it is increasingly likely to be in response to in-stent restenosis, whereby previously it was performed in those with prior CABG. The recent SYNTAX trial has reaffirmed the position of CABG in the treatment of those with complex coronary disease. Consequently we believe that matters have turned a full circle, and expect that SR in the future is most likely to be in form of PCI on patients 8-15 years post primary CABG.
Shiomi, Hiroki; Morimoto, Takeshi; Furukawa, Yutaka; Nakagawa, Yoshihisa; Tazaki, Junichi; Sakata, Ryuzo; Okabayashi, Hitoshi; Hanyu, Michiya; Shimamoto, Mitsuomi; Nishiwaki, Noboru; Komiya, Tatsuhiko; Kimura, Takeshi
2015-07-01
Studies evaluating long-term (≥5 years) outcomes of percutaneous coronary intervention (PCI) using drug-eluting stents compared with coronary artery bypass grafting (CABG) in patients with triple-vessel coronary artery disease (TVD) are still limited. We identified 2,978 patients with TVD (PCI: n = 1,824, CABG: n = 1,154) of 15,939 patients with first coronary revascularization enrolled in the Coronary Revascularization Demonstrating Outcome Study in Kyoto PCI/CABG Registry Cohort-2. The primary outcome measure in the present analysis was a composite of death, myocardial infarction (MI), and stroke. Median follow-up duration for the surviving patients was 1,973 days (interquartile range 1,700 to 2,244). The cumulative 5-year incidence of death/MI/stroke was significantly higher in the PCI group than in the CABG group (28.2% vs 24.0%, log-rank p = 0.006). After adjusting for confounders, the excess risk of PCI relative to CABG for death/MI/stroke remained significant (hazard ratio [HR] 1.38, 95% confidence interval [CI] 1.13 to 1.68, p = 0.002). The excess risks of PCI relative to CABG for all-cause death, MI, and any coronary revascularization were also significant (HR 1.38, 95% CI 1.10 to 1.74, p = 0.006; HR 2.81, 95% CI 1.69 to 4.66, p <0.001; and HR 4.10, 95% CI 3.32 to 5.06, p <0.001, respectively). The risk for stroke was not significantly different between the PCI and CABG groups (HR 0.88, 95% CI 0.61 to 1.26, p = 0.48). There were no interactions for the primary outcome measure between the mode of revascularization (PCI or CABG) and the subgroup factors such as age, diabetes, and Synergy Between PCI With Taxus and Cardiac Surgery score. In conclusion, CABG compared with PCI was associated with better long-term outcome in patients with TVD. Copyright © 2015 Elsevier Inc. All rights reserved.
The nature and pattern of coronary stent recalls.
Kumar, Sanjay; Innasimuthu, Antony L; Marmur, Jonathan D
2014-09-01
Each year, over 1 million percutaneous coronary interventions (PCIs) are performed in the United States. Coronary stents have been shown to reduce restenosis or abrupt vessel closure and therefore have improved the success of PCI. Rarely, manufacturers recall stents due to unanticipated problems. We sought to study the extent and pattern of stent recall. To determine the number and rate of stent recall and safety alerts, to identify trends in the rates, and to identify the nature of stent recalls. The Food and Drug Administration (FDA; http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfRES/res.cfm) and Healthcare Recall Management websites (RASMAS; https://alerts.rasmas.noblis.org/rasmas/c/selectViewAlertList.do) were searched. The search terms for recall were, "coronary stent" or "stent." Dates were searched between November 2002 and June 2013. There were 17 coronary stent recalls involving almost 500,000 units; 12 recalls (71%) were before 2006 and 5 recalls (29%) were after. Thirteen recalls (76%) consisted of class II recalls (moderate hazard); the remaining 4 were equally split between class I (severe hazard) and class III (mild hazard; 12% each). The common reasons for recall were concerns with sterility (29%) followed by wrong labeling/packaging (23%) and impaired delivery of stent (18%). In terms of units involved with recalls, 98% (472,189/481,131) were related to wrong labeling/ packaging or misbranding, while 0.1% (542/481,131) were related to potential for broken struts or crack in inflation port hub or sterility. However, approximately 2% of units were related to the potentially lethal problem of impaired balloon inflation. Recalls involved multiple manufacturers with various stent types. The overall incidence of coronary stent recall is low and has declined over the years. The majority of stent recalls are of moderate hazard. However, due to the possibility of serious injury, clinicians should be aware of recalls.
Diabetes mellitus: a prothrombotic state Implications for outcomes after coronary revascularization
Cola, Clarissa; Brugaletta, Salvatore; Yuste, Victoria Martín; Campos, Bieito; Angiolillo, Dominick J; Sabaté, Manel
2009-01-01
Coronary stent thrombosis is a serious problem in the drug-eluting stent era. Despite aggressive antiplatelet therapy during and after percutaneous coronary intervention (PCI), the incidence of sub-acute stent thrombosis remains approximately 0.5%–2%, which may represent a catastrophic clinical situation. Both procedural factors and discontinuation of antiplatelet therapy are normally associated with this event. We report on simultaneous stent thromboses of two drug-eluting stents implanted in two different vessels, which resulted in a life-threatening clinical condition. Possible contributing factors that led to synergistic thrombotic effects are discussed. PMID:19436654
Javanbakht, Mehdi; Bakhsh, Razieh Yazdani; Mashayekhi, Atefeh; Ghaderi, Hossein; Sadeghi, Masoumeh
2014-10-01
The aim of this study was to evaluate cost effectiveness of coronary artery bypass graft (CABG) versus percutaneous coronary intervention (PCI) with stenting from Iran society perspective. A retrospective study was carried out to estimate the annual cost and health related quality of life (HRQoL) of 109 patients who underwent coronary revascularization (PCI [n = 75] and CABG [n = 34]). A Markov model has been developed to determine the cost effectiveness of CABG compared with PCI. We used the model to calculate lifetime costs, life-years (LYs), and quality-adjusted life-years (QALYs) of each strategy. We also used probabilistic sensitivity analysis to test model robustness. We found that discounted QALY lived per person in CABG versus PCI group in 5 years, 10 years, and lifetime time horizon were (3.8 ± 0.13 versus 3.88 ± 0.14), (6.4 ± 0.23 versus 6.33 ± 0.22), and (8.74 ± 0.29 versus 8.33 ± 0.27), respectively. The estimated medical cost of CABG and PCI per patient in 5 years, 10 years, and lifetime time horizon were (USD 6,819 ± 765 versus 9,011 ± 1,816), (USD 8,852 ± 1,348 versus 12,034 ± 2,375), and (USD 14,037± 4,201 versus 18,798 ± 5,821), respectively. The incremental cost-effectiveness ratio results showed CABG is a dominate alternative in 10 years and lifetime time horizon. This study demonstrated that despite higher initial cost and lower HRQoL, CABG is a cost-effective revascularization strategy compared with PCI for patients with multivessel coronary artery disease in long-term.
Desai, Sonali P; Januzzi, James L; Pande, Ashvin N; Pomerantsev, Eugene V; Resnic, Frederic S; Fossel, Anne; Chibnik, Lori B; Solomon, Daniel H
2010-12-01
Rheumatoid arthritis (RA) is associated with an increased prevalence of coronary artery disease (CAD). We investigated the presenting symptoms of CAD, coronary anatomy (single versus multi-vessel CAD), and treatment among a group of subjects undergoing percutaneous coronary intervention (PCI) with angioplasty and/or stenting. We evaluated a retrospective cohort of 43 RA subjects and 43 matched non-RA subjects undergoing PCI at 2 academic referral centers. RA subjects were matched to non-RA subjects on age, gender, history of coronary artery bypass grafting, date of PCI, and interventional cardiologist. We compared cardiac risk factors, presentation, treatment, and outcomes. The mean age of the study cohort was 71 ± 10 years, and the distribution of traditional cardiac risk factors was similar in the subjects with RA compared with the matched non-RA subjects (all P values > 0.05). Seventy-four percent of subjects with RA compared with 67% of those without RA presented with an acute coronary syndrome before PCI (P = 0.48). All subjects in this cohort undergoing PCI had at least 1 stenosis in a major epicardial vessel and similar percentages of subjects with RA (44%) and without RA (40%) had multi-vessel CAD (P = 0.66). The administration of cardiac medications both at PCI and at hospital discharge was not different among subjects with RA compared with matched non-RA subjects. Among this cohort with significant CAD undergoing PCI, clinical characteristics, presentation, severity of CAD, treatment modalities, and outcomes were similar in subjects with RA and well-matched non-RA subjects. Copyright © 2010 Elsevier Inc. All rights reserved.
Gao, Yue-chun; Yu, Xian-peng; He, Ji-qiang; Chen, Fang
2012-01-01
To assess the value of SYNTAX score to predict major adverse cardiac and cerebrovascular events (MACCE) among patients with three-vessel or left-main coronary artery disease undergoing percutaneous coronary intervention. 190 patients with three-vessel or left-main coronary artery disease undergoing percutaneous coronary intervention (PCI) with Cypher select drug-eluting stent were enrolled. SYNTAX score and clinical SYNTAX score were retrospectively calculated. Our clinical Endpoint focused on MACCE, a composite of death, nonfatal myocardial infarction (MI), stroke and repeat revascularization. The value of SYNTAX score and clinical SYNTAX score to predict MACCE were studied respectively. 29 patients were observed to suffer from MACCE, accounting 18.5% of the overall 190 patients. MACCE rates of low (≤ 20.5), intermediate (21.0 - 31.0), and high (≥ 31.5) tertiles according to SYNTAX score were 9.1%, 16.2% and 30.9% respectively. Both univariate and multivariate analysis showed that SYNTAX score was the independent predictor of MACCE. MACCE rates of low (≤ 19.5), intermediate (19.6 - 29.1), and high (≥ 29.2) tertiles according to clinical SYNTAX score were 14.9%, 9.8% and 30.6% respectively. Both univariate and multivariate analysis showed that clinical SYNTAX score was the independent predictor of MACCE. ROC analysis showed both SYNTAX score (AUC = 0.667, P = 0.004) and clinical SYNTAX score (AUC = 0.636, P = 0.020) had predictive value of MACCE. Clinical SYNTAX score failed to show better predictive ability than the SYNTAX score. Both SYNTAX score and clinical SYNTAX score could be independent risk predictors for MACCE among patients with three-vessel or left-main coronary artery disease undergoing percutaneous coronary intervention. Clinical SYNTAX score failed to show better predictive ability than the SYNTAX score in this group of patients.
[SICI-GISE position paper on drug-coated balloon use in the coronary district].
Cortese, Bernardo; Sgueglia, Gregory A; Berti, Sergio; Biondi-Zoccai, Giuseppe; Colombo, Antonio; Limbruno, Ugo; Bedogni, Francesco; Cremonesi, Alberto
2013-10-01
Drug-coated balloons are a new tool for the treatment of patients with coronary artery disease. The main feature of this technology is a rapid and homogeneous transfer of an antiproliferative drug (paclitaxel) to the vessel wall just at the time of balloon inflation, when neointimal proliferation, in response to angioplasty, is the highest. Moreover, drug-coated balloons share adjunctive advantages over stents: the absence of permanent scaffold and polymer, the respect of the original coronary anatomy, and limited inflammatory stimuli, thereby allowing for short-term dual antiplatelet therapy. At present, a variety of devices are available in the market, with limited scientific data for the vast majority of them. Thus, the Italian Society of Interventional Cardiology (SICI-GISE) decided to coordinate the efforts of a group of renowned experts in this field, in order to produce a position paper on the correct use of drug-coated balloons in all settings of coronary artery disease, giving a class of indication to each one, based on clinical evidence. This position paper represents a quick reference for operators, investigators and manufacturers to promote the understanding and the correct use of the drug-coated balloon technology in everyday clinical practice.
Kim, Chi-Hoon; Han, Jung-Kyu; Yang, Han-Mo; Park, Kyung Woo; Lee, Hae-Young; Kang, Hyun-Jae; Koo, Bon-Kwon; Lee, Namho; Cha, Tae-Joon; Yang, Tae-Hyun; Jeong, Myung-Ho; Yoon, Myeong-Ho; Lee, Seung Uk; Lee, Seung Jin; Kim, Jin Won; Cho, Jin-Man; Han, Kyoo-Rok; Pyun, Wook Bum; Kim, Hyo-Soo
2017-10-11
We have recently seen the introduction of newer generation drug-eluting stents with ultrathin struts that use advanced polymer technologies. However, the efficacy and safety of these newest stents have not yet been fully explored. In addition, there are still controversies over the optimal duration of dual antiplatelet therapy (DAPT) after stent implantation, particularly for ultrathin stents with the newest polymer technologies. The HOST-IDEA trial is a randomised, open-label, multicentre, non-inferiority trial and the first study to directly compare two of these ultrathin sirolimus-eluting stents: Orsiro stent with biodegradable polymer, and polymer-free Coroflex ISAR (CX-ISAR) stent. This study has a scheme of 2×2 factorial design according to the stent type and DAPT duration (3 vs 12 months). A total of 2152 patients will be randomised and stratified to demonstrate the non-inferiority of CX-ISAR to Orsiro, or of the abbreviated DAPT duration to the conventional 12 months (both in 1:1 ratio). For the comparison of stent type, the primary endpoint is target lesion failure (TLF), which is a composite of cardiac death, target vessel-related myocardial infarction and clinically driven target lesion revascularisation. For the comparison of DAPT duration, the net adverse clinical event is the coprimary endpoint, which is defined as a composite of TLF, definite/probable stent thrombosis and major bleeding. All the institutions involved in this study are required to have ethical approval prior to patient enrolment. This multicentre study will recruit patients through competitive registration, but institutions that have not yet obtained ethical approvals have made it impossible to enrol patients in a centralised web database. The final results will be presented at relevant international conferences and will be materialised in the form of papers. NCT02601157; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Safety Outcomes Using a Proximal Protection Device in Carotid Stenting of Long Carotid Stenoses
Atchaneeyasakul, Kunakorn; Khandelwal, Priyank; Ambekar, Sudheer; Ramdas, Kevin; Guada, Luis; Yavagal, Dileep
2016-01-01
Background Embolic protection devices can prevent atherosclerotic emboli during carotid stenting. Newer proximal protection devices reverse flow in the internal carotid artery (ICA), leading to reduction in perioperative microemboli. The risk of stroke is high for carotid stenting of ICA lesions with a length >10 mm and/or angiographic string sign. Objective We aimed to evaluate the safety outcomes of proximal embolic protection device usage in this high-risk group. Methods This is a retrospective analysis of patients who underwent carotid stenting procedures with proximal embolic protection devices at a tertiary care center. High-risk features for adverse events with carotid stenting were identified. Peri- and postprocedural outcomes were recorded. We further compared outcomes in patients with a carotid stenosis length >10 mm to those with shorter stenosis. Results From January 2011 to December 2014, we included 27 patients; 96.3% were symptomatic and 3.7% were asymptomatic. There was a stent placement technical success rate of 100%. No major stroke or coronary events were recorded. One minor stroke event developed in one patient. A carotid lesion length >10 mm and/or angiographic string sign was noted in 21/27 patients, with an average lesion length of 14.4 mm. One patient (4.8%) in this group developed a minor stroke event. Neither a coronary nor a major stroke event was recorded in this group. There was no significant difference in the complication rate between the long lesion and the control group. Conclusion In our patient cohort, it was found that a proximal embolic protection device is safe for patients with carotid stenosis, including those with a carotid lesion length >10 mm and/or angiographic string sign. PMID:27781040
Economic evaluation of drug-eluting stents in coronary angioplasty.
Santos, Ricardo; Pereira, Hélder
2005-11-01
Coronary angioplasty has revolutionized the treatment of coronary artery disease, from the first balloon angioplasty to the current era of drug-eluting stents (DES), which were developed to eliminate the bare metal stent's (BMS) Achilles' heel, restenosis. DES have an extremely low restenosis rate but are significantly more expensive and need more prolonged dual antiplatelet therapy. Restenosis has a generally benign prognosis and is not associated with higher mortality or major adverse cardiovascular events, which has limited the penetration of DES, whose only advantage is the reduction of restenosis. Economic evaluation of DES is therefore of paramount importance for assessing their appropriate use. In randomized trials in which they are compared with BMS, economic evaluation is advantageous for DES, with good cost-effectiveness ratios for both cost per quality-adjusted life year (QALY) and cost per revascularization avoided. However, these trials have two major limitations--the angiographic follow-up protocol and selection of patients with lower risk--and so their results do not accurately reflect reality. Other studies with unselected populations and cost-effectiveness models show that there is an economic advantage in the use of DES in groups with higher risk of restenosis, but not for the whole population undergoing angioplasty. Use of DES will be more appropriate if we can identify populations with a higher likelihood of restenosis, because these are the patients that will benefit most from their use and in whom they will be economically advantageous.
An argument for the use of multiple segment stents in curved arteries.
Kasiri, Saeid; Kelly, Daniel J
2011-08-01
Stenting of curved arteries is generally perceived to be more challenging than straight vessels. Conceptually implanting multiple shorter stents rather than a single longer stent into such a curved artery represents a promising concept, but little is known about the impact of such an approach. The objective of this study is to evaluate the effectiveness of using a multiple segment stent rather than a single long stent to dilate a curved artery using the finite element method. A double segment stent (DSS) and a single segment stent (SSS) were modeled. The stents were compared when expanded into a model of a curved artery. The model predicts that the DSS provides higher flexibility, more conformity, and lower recoil in comparison to the SSS. The volume of arterial tissue experiencing high levels of stress due to stent implantation is also reduced for the DSS. It is suggested that a multiple segment stenting system is a potential solution to the problem of higher rates of in-stent restenosis in curved arteries and mechanically challenging environments.
Mahmud, Ehtisham; Naghi, Jesse; Ang, Lawrence; Harrison, Jonathan; Behnamfar, Omid; Pourdjabbar, Ali; Reeves, Ryan; Patel, Mitul
2017-07-10
The aims of this study were to evaluate the feasibility and technical success of robotically assisted percutaneous coronary intervention (R-PCI) for the treatment of coronary artery disease (CAD) in clinical practice, especially in complex lesions, and to determine the safety and clinical success of R-PCI compared with manual percutaneous coronary intervention (M-PCI). R-PCI is safe and feasible for simple coronary lesions. The utility of R-PCI for complex coronary lesions is unknown. All consecutive PCI procedures performed robotically (study group) or manually (control group) over 18 months were included. R-PCI technical success, defined as the completion of the procedure robotically or with partial manual assistance and without a major adverse cardiovascular event, was determined. Procedures ineligible for R-PCI (i.e., atherectomy, planned 2-stent strategy for bifurcation lesion, chronic total occlusion requiring hybrid approach) were excluded for analysis from the M-PCI group. Clinical success, defined as completion of the PCI procedure without a major adverse cardiovascular event, procedure time, stent use, and fluoroscopy time were compared between groups. A total of 315 patients (mean age 67.7 ± 11.8 years; 78% men) underwent 334 PCI procedures (108 R-PCIs, 157 lesions, 78.3% type B2/C; 226 M-PCIs, 336 lesions, 68.8% type B2/C). Technical success with R-PCI was 91.7% (rate of manual assistance 11.1%, rate of manual conversion 7.4%, rate of major adverse cardiovascular events 0.93%). Clinical success (99.1% with R-PCI vs. 99.1% with M-PCI; p = 1.00), stent use (stents per procedure 1.59 ± 0.79 with R-PCI vs. 1.54 ± 0.75 with M-PCI; p = 0.73), and fluoroscopy time (18.2 ± 10.4 min with R-PCI vs. 19.2 ± 11.4 min with M-PCI; p = 0.39) were similar between the groups, although procedure time was longer in the R-PCI group (44:30 ± 26:04 min:s vs. 36:34 ± 23:03 min:s; p = 0.002). Propensity-matched analysis confirmed that procedure time was longer in the robotic group (42:59 ± 26:14 min:s with R-PCI vs. 34:01 ± 17:14 min:s with M-PCI; p = 0.007), although clinical success remained similar (98.8% with R-PCI vs. 100% with M-PCI; p = 1.00). This study demonstrates the feasibility, safety, and high technical success of R-PCI for the treatment of complex coronary disease. Furthermore, comparable clinical outcomes, without an adverse effect on stent use or fluoroscopy time, were observed with R-PCI and M-PCI. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Abizaid, Alexandre; Costa, J Ribamar; Banning, Adrian; Bartorelli, Antonio L; Dzavik, Vladimir; Ellis, Stephen; Gao, Runlin; Holmes, David R; Jeong, Muyng Ho; Legrand, Victor; Neumann, Franz-Josef; Nyakern, Maria; Orlick, Amy; Spaulding, Christian; Worthley, Stephen; Urban, Philip M
2012-01-01
This study sought to compare the 1-year safety and efficacy of Cypher Select or Cypher Select Plus (Cordis Corporation, Bridgewater, New Jersey) sirolimus-eluting stents (SES) with the treatment of bare-metal stents (BMS) and drug-eluting stent (DES) in-stent restenosis (ISR) in nonselected, real-world patients. There is paucity of consistent data on DES for the treatment of ISR, especially, DES ISR. The e-SELECT (Multicenter Post-Market Surveillance) registry is a Web-based, multicenter and international registry encompassing virtually all subsets of patients and lesions treated with at least 1 SES during the period from 2006 to 2008. We enrolled in this pre-specified subanalysis all patients with at least 1 clinically relevant BMS or DES ISR treated with SES. Primary endpoint was major adverse cardiac events and stent thrombosis rate at 1 year. Of 15,147 patients enrolled, 1,590 (10.5%) presented at least 1 ISR (BMS group, n = 1,235, DES group, n = 355). Patients with DES ISR had higher incidence of diabetes (39.4% vs. 26.9%, p < 0.001), renal insufficiency (5.8% vs. 2.3%, p = 0.003), and prior coronary artery bypass graft (20.5% vs. 11.8%, p < 0.001). At 1 year, death (1.4% for BMS vs. 2.1% for DES, p = 0.3) and myocardial infarction (2.4% for BMS and 3.3% for DES, p = 0.3) rates were similar, whereas ischemia-driven target lesion revascularization and definite/probable late stent thrombosis were higher in patients with DES ISR (6.9% vs. 3.1%, p = 0.003, and 1.8% vs. 0.5%, p = 0.04, respectively). Use of SES for either BMS or DES ISR treatment is safe and associated with low target lesion revascularization recurrence and no apparent safety concern. Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Leibowitz, David; Cohen, Maurice; Planer, David; Mosseri, Morris; Rott, David; Lotan, Chaim; Weiss, A Teddy
2006-04-15
Previous studies have shown a high incidence of cardiovascular complications when noncardiac surgery (NCS) is performed after coronary stenting. No study has compared the outcomes of NCS after stenting compared with percutaneous transluminal coronary angioplasty (PTCA) alone. The records of all patients who underwent NCS within 3 months of percutaneous coronary intervention at our institution were reviewed for adverse clinical events with the end points of acute myocardial infarction, major bleeding, and death < or = 6 months after NCS. A total of 216 consecutive patients were included in the study. Of these, 122 (56%) underwent PTCA and 94 (44%) underwent stenting. A total of 26 patients (12%) died, 13 in the stent group (14%) and 13 in the PTCA group (11%), a nonsignificant difference. The incidence of acute myocardial infarction and major bleeding was 7% and 16% in the stent group and 6% and 13% in the PTCA group (p = NS), respectively. Significantly more events occurred in the 2 groups when NCS was performed within 2 weeks of percutaneous coronary intervention. In conclusion, our study has demonstrated high rates of perioperative morbidity and mortality after NCS in patients undergoing PTCA alone, as well as stenting. These findings support the current guidelines regarding the risk of NCS after stenting but suggest they be extended to PTCA as well.
Thrombus Extraction Catheters vs. Angiojet Rheolytic Thrombectomy in Thrombotic Lesions/SV Grafts
Alexopoulos, Dimitrios; Davlouros, Periklis A
2012-01-01
Primary percutaneous coronary intervention, (pPCI), of native coronaries and saphenous vein grafts (SVGs), is the recommended reperfusion strategy for STEMI, and an early invasive approach is recommended for high risk patients with UA/NSTEMI. Although PCI effectively restores flow in the infarct related artery/culprit vessel in both situations, myocardial perfusion often remains suboptimal due to microvascular obstruction, partly attributed to distal embolization of thrombus. Hence, thrombectomy (manual or mechanical), prior to stenting may further reduce hard clinical end points in patients with ACS. This article discusses accumulated evidence regarding the safety and effectiveness of thrombectomy in culprit native coronaries and SVGs in such patients, as well as possible strategies for maximizing its benefits relative to the size of the thrombotic burden. PMID:22920486
Myocardial infarction with Moyamoya disease and pituitary gigantism in a young female patient.
Ahn, Y K; Jeong, M H; Bom, H S; Park, J C; Kim, J K; Chung, D J; Chung, M Y; Cho, J G; Kang, J C
1999-08-01
Myocardial infarction is very rare in young female patients with systemic vascular disorders. Moyamoya disease is a cerebrovascular disease associated with an abnormal vascular network. This report presents a 19-year-old female patient who suffered from chest pain and exertional dyspnea for 2 months prior to admission. She had a history of Moyamoya disease and pituitary gigantism since childhood. Her ejection fraction on echocardiogram was 20% and a perfusion defect with partial reversibility in the anterior wall was demonstrated on stress single photon emission computed tomography (SPECT). Diagnostic coronary angiogram revealed critical stenosis in the middle left anterior descending artery, which was treated by coronary stenting. Her subjective symptoms were relieved and the perfusion defect seen on SPECT decreased after coronary intervention.
Marui, Akira; Kimura, Takeshi; Nishiwaki, Noboru; Mitsudo, Kazuaki; Komiya, Tatsuhiko; Hanyu, Michiya; Shiomi, Hiroki; Tanaka, Shiro; Sakata, Ryuzo
2014-10-01
Coronary heart disease is a major risk factor for left ventricular (LV) systolic dysfunction. However, limited data are available regarding long-term benefits of percutaneous coronary intervention (PCI) in the era of drug-eluting stent or coronary artery bypass grafting (CABG) in patients with LV systolic dysfunction with severe coronary artery disease. We identified 3,584 patients with 3-vessel and/or left main disease of 15,939 patients undergoing first myocardial revascularization enrolled in the CREDO-Kyoto PCI/CABG Registry Cohort-2. Of them, 2,676 patients had preserved LV systolic function, defined as an LV ejection fraction (LVEF) of >50% and 908 had impaired LV systolic function (LVEF≤50%). In patients with preserved LV function, 5-year outcomes were not different between PCI and CABG regarding propensity score-adjusted risk of all-cause and cardiac deaths. In contrast, in patients with impaired LV systolic function, the risks of all-cause and cardiac deaths after PCI were significantly greater than those after CABG (hazard ratio 1.49, 95% confidence interval 1.04 to 2.14, p=0.03 and hazard ratio 2.39, 95% confidence interval 1.43 to 3.98, p<0.01). In both patients with moderate (35%
Direct comparison of the short-term clinical performance of Z Guidant and Taxus stents.
Guildford, Anna; Colombo, Paola; Bruschi, Giuseppe; Bonacina, Edgardo; Klugmann, Silvio; Santin, Matteo
2010-12-03
The recent introduction of drug-eluting stents in angioplasty of atherosclerotic blood vessels has significantly reduced the risks of in-stent restenosis (ISR) [1]. Indeed, it is known that in conventional stents ISR takes place in over 20% of the cases and up to 60% when implanted in diabetic patients. Conversely, clinical trials have shown that drug-eluting stents have significantly reduced ISR. Among the drug-eluting stents available on the market, Taxus stents (Tax, Boston Scientific, USA) are among the most used devices [2]. Tax are stainless-steel stents coated with Translute, a poly(styrene-b-isobutylene-b-styrene) polymer (PSIBS) eluting Placlitaxel, an anti-mitotic drug. Clinical trials on this type of drug-eluting stents have shown an incidence of restenosis of approximately 4%. The majority of these trials were randomized studies where conventional stents and drug-eluting devices have been implanted in separate patients' cohorts. Such a randomized design, although fundamental to collect statistically-relevant data, does not allow a direct histological comparison of different stent types when implanted in the same patient and do not show the individual susceptibility to the host response especially at short-term implantation times. Here, an interesting case study is presented where two chrome-cobalt stents (Z Guidant, ZG, Guidant Corp.) and a Tax have been simultaneously implanted in the same patient in three separate coronary arteries, retrieved after only 8 weeks and histologically analysed. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.
Surface Topographical Modification of Coronary Stent: A Review
NASA Astrophysics Data System (ADS)
Tan, C. H.; Muhamad, N.; Abdullah, M. M. A. B.
2017-06-01
Driven by the urge of mediating the inflammatory response from coronary stent implant to improve patency rates of the current coronary stent, concern has been focusing on reducing the risk of in-stent restenosis and thrombosis for long-term safety. Surface modification approach has been found to carry great potential due to the surface is the vital parts that act as a buffer layer between the biomaterial and the organic material like blood and vessel tissues. Nevertheless, manipulating cell response in situ using physical patterning is very complex as the exact mechanism were yet elucidated. Thus, the aim of this review is to summarise the recent efforts on modifying the surface topography of coronary stent at the micro- and nanometer scale with the purpose of inducing rapid in situ endothelialization to regenerate a healthy endothelium layer on biomaterial surface. In particular, a discussion on the surface patterns that have been investigated on cell selective behaviour together with the methods used to generate them are presented. Furthermore, the probable future work involving the surface modification of coronary stent were indicated.
Teichman, Jennifer; Taher, Ahmed; Hashi, Abdulaziz; Bagai, Akshay; Sholzberg, Michelle
2018-01-01
More recent immune thrombocytopenia (ITP) treatment strategies enhance platelet production with the use of thrombopoietin receptor agonists (TPO-RA) such as eltrombopag. Patients receiving TPO-RA agents may be at an increased risk of thromboembolism, however the pathophysiology and common underlying risk factors are not well understood. We present the case of a young asplenic woman on eltrombopag for chronic ITP with acute myocardial infarction involving the right coronary artery. Past medical history was significant for remote mediastinal radiation for lymphoma and splenectomy for ITP. She had no other risk factors for coronary artery disease. She underwent coronary catheterization and balloon angioplasty to the culprit lesion, although stenting was deferred due to concerns with dual antiplatelet therapy. She was discharged from hospital on single antiplatelet therapy with acetylsalicylic acid. We believe that the patient's ITP, recent eltrombopag use, surgical asplenia and history of mediastinal radiation synergistically contributed to her myocardial infarction. The risks of bleeding and thromboembolism must be carefully weighed in patients receiving TPO-RA therapy.
Araki, Tadashi; Ikeda, Nobutaka; Shukla, Devarshi; Jain, Pankaj K; Londhe, Narendra D; Shrivastava, Vimal K; Banchhor, Sumit K; Saba, Luca; Nicolaides, Andrew; Shafique, Shoaib; Laird, John R; Suri, Jasjit S
2016-05-01
Percutaneous coronary interventional procedures need advance planning prior to stenting or an endarterectomy. Cardiologists use intravascular ultrasound (IVUS) for screening, risk assessment and stratification of coronary artery disease (CAD). We hypothesize that plaque components are vulnerable to rupture due to plaque progression. Currently, there are no standard grayscale IVUS tools for risk assessment of plaque rupture. This paper presents a novel strategy for risk stratification based on plaque morphology embedded with principal component analysis (PCA) for plaque feature dimensionality reduction and dominant feature selection technique. The risk assessment utilizes 56 grayscale coronary features in a machine learning framework while linking information from carotid and coronary plaque burdens due to their common genetic makeup. This system consists of a machine learning paradigm which uses a support vector machine (SVM) combined with PCA for optimal and dominant coronary artery morphological feature extraction. Carotid artery proven intima-media thickness (cIMT) biomarker is adapted as a gold standard during the training phase of the machine learning system. For the performance evaluation, K-fold cross validation protocol is adapted with 20 trials per fold. For choosing the dominant features out of the 56 grayscale features, a polling strategy of PCA is adapted where the original value of the features is unaltered. Different protocols are designed for establishing the stability and reliability criteria of the coronary risk assessment system (cRAS). Using the PCA-based machine learning paradigm and cross-validation protocol, a classification accuracy of 98.43% (AUC 0.98) with K=10 folds using an SVM radial basis function (RBF) kernel was achieved. A reliability index of 97.32% and machine learning stability criteria of 5% were met for the cRAS. This is the first Computer aided design (CADx) system of its kind that is able to demonstrate the ability of coronary risk assessment and stratification while demonstrating a successful design of the machine learning system based on our assumptions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Morice, Marie-Claude; Feldman, Ted E E; Mack, Michael J; Ståhle, Elisabeth; Holmes, David R; Colombo, Antonio; Morel, Marie-Angèle; van den Brand, Marcel; Serruys, Patrick W; Mohr, Friedrich; Carrié, Didier; Fournial, Gérard; James, Stefan; Leadley, Katrin; Dawkins, Keith D; Kappetein, A Pieter
2011-10-30
The SYNTAX-LE MANS substudy prospectively evaluated 15-month angiographic and clinical outcomes in patients with treated left main (LM) disease. In the SYNTAX trial, 1,800 patients with three-vessel and/or LM disease were randomised to either CABG or PCI; of these, 271 LM patients were prospectively assigned to receive a 15-month angiogram. The primary endpoint for the CABG arm was the ratio of ≥50% to <100% obstructed/occluded grafts bypassing LM lesions to the number placed. The primary endpoint for the PCI arm was the proportion of patients with ≤50% diameter stenosis ('patent' stents) of treated LM lesions. Per protocol, no formal comparison between CABG and PCI arms was intended based on the differing primary endpoints. Available 15-month angiograms were analysed for 114 CABG and 149 PCI patients. At 15 months, 9.9% (26/263) of CABG grafts were 100% occluded and an additional 5.7% (15/263) were ≥50% to <100% occluded. Overall, 27.2% (31/114) of patients had ≥1 obstructed/occluded graft. The 15-month CABG MACCE rate was 8.8% (10/114) and MACCE at 15 months was not significantly associated with graft obstruction/occlusion (p=0.85). In the PCI arm, 92.4% (134/145) of patients had ≤50% diameter LM stenosis at 15 months (89.7% [87/97] distal LM lesions and 97.9% [47/48] non-distal LM lesions). The 15-month PCI MACCE rate was 12.8% (20/156) and this was significantly associated with lack of stent patency at 15 months (p<0.001), mainly due to repeat revascularisation. At 15 months, 15.6% (41/263) of grafts were at least 50% obstructed but this was not significantly associated with MACCE; 92.4% (134/145) of patients had stents that remained patent at 15 months, and stent restenosis was significantly associated with MACCE, predominantly due to revascularisation.
Mester, Petru; Bouvaist, Helene; Delarche, Nicolas; Bouisset, Frédéric; Abdellaoui, Mohamed; Petiteau, Pierre-Yves; Dubreuil, Olivier; Boueri, Ziad; Chettibi, Mohamed; Souteyrand, Géraud; Madiot, Hend; Belle, Loic
2017-07-20
The aim of this study was to ascertain whether a minimalist immediate mechanical intervention (MIMI) aiming to restore an optimal Thrombolysis In Myocardial Infarction (TIMI) flow in the culprit artery, followed ≥7 days later by a second percutaneous coronary intervention with intentional stenting, is safe in patients with ST-segment elevation myocardial infarction and large thrombotic burden. SUPER-MIMI was a prospective, observational trial conducted between January 2014 and April 2015 in 14 French centres. A total of 155 patients were enrolled. The pharmacological therapy was left to the operator's discretion. Eighty-one patients (52.3%) had glycoprotein IIb/IIIa inhibitors (GPI) initiated before the end of the first procedure. The median (interquartile range [IQR]) delay between the two procedures was eight (seven to 12) days. Infarct-related artery reocclusion between the two procedures (primary endpoint) occurred in two patients (1.3%), neither of whom received GPI treatment. TIMI flow was maintained or improved between the end of the first procedure and the beginning of the second procedure in all patients. Thrombotic burden and stenosis severity diminished significantly between the two procedures. Stents were ultimately implanted in 97 patients (62.6%). Deferred stenting (≥7 days) in patients with a high thrombus burden was safe on a background of GPI therapy.
Lee, Joo Myung; Cho, Deok-Kyu; Hahn, Joo-Yong; Song, Young Bin; Park, Taek Kyu; Oh, Ju-Hyeon; Lee, Jin Bae; Doh, Joon-Hyung; Kim, Sang-Hyun; Yang, Jeong Hoon; Choi, Jin-Ho; Choi, Seung-Hyuck; Lee, Sang Hoon; Gwon, Hyeon-Cheol
2016-12-01
Dual antiplatelet therapy (DAPT) is a fundamental treatment that optimizes clinical outcomes after percutaneous coronary intervention, especially in patients with acute coronary syndrome (ACS). Although current international guidelines recommend DAPT for at least 12 months after implantation of a drug-eluting stent in patients with ACS, these recommendations are not based on randomized controlled trials dedicated to ACS population. The SMART-DATE trial is a prospective, multicenter, randomized, and open-label study to demonstrate the noninferiority of 6-month DAPT compared with 12 months or longer DAPT in patients with ACS undergoing percutaneous coronary intervention. A total of 2,700 patients will undergo prospective, random assignment to either of the DAPT duration groups. To minimize the bias from different stent devices, the type of stents will be randomly assigned (everolimus-eluting stents, zotarolimus-eluting stents, or biolimus A9-eluting stents). The primary end point is a composite of all-cause death, myocardial infarction, and cerebrovascular events at 18 months after the index procedure. The major secondary end points are definite/probable stent thrombosis defined by the Academic Research Consortium and bleeding defined by Bleeding Academic Research Consortium type 2-5. The SMART-DATE randomized trial is the first study exploring the safety of 6-month DAPT compared with conventional 12-month or longer DAPT dedicated to patients with ACS after second-generation drug-eluting stent implantation. Copyright © 2016 Elsevier Inc. All rights reserved.
[Acute myocardial infarction after wasp sting without anaphylactic reaction].
Bongo, Angelo Sante; Fornaro, Gianluigi; Sansa, Mara; Macciò, Sergio; Rognoni, Andrea
2005-03-01
Bites of hymenopterans (bees, wasps and hornets) are very frequent phenomena that can stir up allergical reactions in venom-susceptible patients but that seldom provoke acute myocardial infarction. In the literature we can find case reports of myocardial infarction after bites of hymenopterans, and preceded by an allergic reaction (sometimes with angiographic evidence of undamaged coronary arteries). The pathophysiological determinant seems to be related to the chemical composition of hymenopterans venom, basically made up by vasoactive and thrombogenic substances able to create vasospasm and coronary thrombosis. Our report refers to a 65-year-old male patient without prior cardiological and allergic events who, bitten by a sharm of three bees, complains of an acute large anterior myocardial infarction with angiographic evidence of thrombotic lesion of the proximal left anterior descending artery treated with direct stenting with procedural success, without showing allergical symptoms. The pathophysiological determinant seems to be related to the release of vasoactive amines and thrombogenic substances contained into the hymenopterans venom, the former able to produce vasospasm, the latter able to create diffuse thrombosis. The use of adrenaline itself to counteract the possible systemic allergic reaction appears to advise against the treatment of patients with cardiological symptoms or coronary artery disease and because of its strong vasoactive activity (it leads, in fact, to vasoconstriction) and thrombogenic effects.
[Clinical study on the coronary artery interventions guided by the magnetic navigation system].
Li, Chun-jian; Wang, Hui; Wang, Lian-sheng; Zhu, Tie-bing; Yang, Zhi-jian; Cao, Ke-jiang
2010-03-01
To investigate the efficacy and safety of the magnetic navigation system used in the real world percutaneous coronary artery intervention. All lesions detected by the coronary artery angiography in the magnetic-navigation catheter lab indicated for percutaneous coronary artery intervention (PCI) were included and treated under the guidance of the magnetic navigation system. The characteristics of the target lesion, process of the procedure, time and dosage of the X-ray exposure, and procedure-related complication were recorded and analyzed. One hundred and twenty one patients with 138 lesions were recruited and intervened by PCI during the period from April 2006 to June 2008. Thirty lesions were classified as type A, 50 as type B1, 36 as type B2, 22 as type C (including seven total occlusions). The average stenosis of the target lesions was (85.3 +/- 10.0)%, mean length was (21.1 +/- 10.0) mm. Under the guidance of the magnetic navigation system, 134 target lesions were passed by the magnetic guide-wires, the lesion passing ratio was 97.1%. The X-ray exposure time, X-ray dosage and the contrast volume used during the period of the wire placement were (55.9 +/- 35.4) seconds, (98.0 +/- 86.1) mGy/(490.0 +/- 422.2) microGym(2) and (8.0 +/- 5.4) ml, respectively. A total of 164 stents were implanted in the vessels where the target lesions were passed by the magnetic wires. There was no magnetic navigation system associated complication. Magnetic guide-wires failed to pass four target lesions, two of which were chronic total occlusions (CTOs), and the other two were calcified subtotal occlusions. It is feasible and safe to adopt the magnetic navigation system for the real-world coronary artery intervention. The magnetic guide-wire possesses a high lesion-passing ratio. The CTOs and calcified subtotal occlusions are not ideal lesions for use of the magnetic navigation system.
Larsen, Sanne Bøjet; Grove, Erik Lerkevang; Neergaard-Petersen, Søs; Würtz, Morten; Hvas, Anne-Mette; Kristensen, Steen Dalby
2017-08-05
Increased platelet aggregation during antiplatelet therapy may predict cardiovascular events in patients with coronary artery disease. The majority of these patients receive aspirin monotherapy. We aimed to investigate whether high platelet-aggregation levels predict cardiovascular events in stable coronary artery disease patients treated with aspirin. We included 900 stable coronary artery disease patients with either previous myocardial infarction, type 2 diabetes mellitus, or both. All patients received single antithrombotic therapy with 75 mg aspirin daily. Platelet aggregation was evaluated 1 hour after aspirin intake using the VerifyNow Aspirin Assay (Accriva Diagnostics) and Multiplate Analyzer (Roche; agonists: arachidonic acid and collagen). Adherence to aspirin was confirmed by serum thromboxane B 2 . The primary end point was the composite of nonfatal myocardial infarction, ischemic stroke, and cardiovascular death. At 3-year follow-up, 78 primary end points were registered. The primary end point did not occur more frequently in patients with high platelet-aggregation levels (first versus fourth quartile) assessed by VerifyNow (hazard ratio: 0.5 [95% CI, 0.3-1.1], P =0.08) or Multiplate using arachidonic acid (hazard ratio: 1.0 [95% CI, 0.5-2.1], P =0.92) or collagen (hazard ratio: 1.4 [95% CI, 0.7-2.8], P =0.38). Similar results were found for the composite secondary end point (nonfatal myocardial infarction, ischemic stroke, stent thrombosis, and all-cause death) and the single end points. Thromboxane B 2 levels did not predict any end points. Renal insufficiency was the only clinical risk factor predicting the primary and secondary end points. This study is the largest to investigate platelet aggregation in stable coronary artery disease patients receiving aspirin as single antithrombotic therapy. We found that high platelet-aggregation levels did not predict cardiovascular events. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Zeng, Xiaofang; Lincoff, A Michael; Schulz-Schüpke, Stefanie; Steg, Philippe Gabriel; Elbez, Yedid; Mehran, Roxana; Stone, Gregg W; McAndrew, Thomas; Lin, Jianhui; Zhang, Xindan; Shi, Wenhai; Lei, Han; Jing, Zhicheng; Huang, Wei
2018-05-01
Patients with chronic kidney disease (CKD) have elevated bleeding and ischemic outcomes. We aim to assess the short- and long-term efficacy and safety of bivalirudin compared to heparin plus glycoprotein IIb/IIIa inhibitors (GPIs) in coronary artery disease (CAD) patients with CKD. Randomized trials were searched in PubMed, Cochrane, and Embase databases up to January 2017. Among the trials retrieved, efficacy endpoints were defined as mortality, myocardial infarction (MI), repeat revascularization, stent thrombosis, and major adverse cardiac events (MACEs). Safety endpoints were reported as non-coronary artery bypass grafting (CABG) related major bleeding and thrombolysis in myocardial infarction (TIMI) major bleeding. Risk ratio (RR) and 95% confidence interval (CI) were calculated for each outcome using a fixed effect model. Five studies with a total of 3796 patients were included. In short-term follow up (30 days), bivalirudin significantly reduced non-CABG related major bleeding (p=0.0004) and TIMI major bleeding (p=0.007) compared to heparin plus GPIs. No significant differences were observed in rates of mortality, MI, repeat revascularization, stent thrombosis, and MACEs between the two groups in short- and long-term follow up (6 months to 3 years). In patients with ST elevated myocardial infarction (STEMI) with concurrent CKD, the decreased non-CABG related major bleeding (p=0.04) without increasing ischemic events was also observed after short-term follow up. (1) Bivalirudin is safer than and as effective as heparin plus GPIs in CAD patients with CKD. (2) Impaired renal function does not affect the safety benefits of bivalirudin. (3) Similar efficacy profiles were identified between the two groups after both short- and long-term follow up in the CAD patients with CKD. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.
Kempe, Maria; Kempe, Henrik; Snowball, Ian; Wallén, Rita; Arza, Carlos Rodriguez; Götberg, Matthias; Olsson, Tommy
2010-12-01
Implant-assisted targeting of magnetic particles under the influence of an external magnetic field has previously been verified through mathematical modeling, in vitro studies, and in vivo studies on rat carotid arteries as a feasible method for localized drug delivery. The present study focuses on the development of nanoparticles for the treatment of in-stent thrombosis. Magnetic nanoparticles in the size-range 10-30 nm were synthesized in a one-pot procedure by precipitation of ferrous hydroxide followed by oxidation to magnetite. The nanoparticles were silanized with tetraethyl orthosilicate in the presence of triethylene glycol and/or polyethylene glycol. The surface coated magnetite nanoparticles were activated with either N-hydroxysulfosuccinimide or tresyl chloride for covalent immobilization of tissue plasminogen activator (tPA). Hysteresis loops showed saturation magnetizations of 55.8, 44.1, and 43.0 emu/g for the naked nanoparticles, the surface coated nanoparticles, and the tPA-nanoparticle conjugates, respectively. The hemolytic activity of the nanoparticles in blood was negligible. An initial in vivo biocompatibility test in pig, carried out by intravascular injection of the nanoparticles in a stented brachial artery, showed no short-term adverse effects. In vitro evaluation in a flow-through model proved that the nanoparticles were captured efficiently to the surface of a ferromagnetic coiled wire at the fluid velocities typical for human arteries. A preliminary test of the tPA-nanoparticle conjugates in a pig model suggested that the conjugates may be used for treatment of in-stent thrombosis in coronary arteries. Copyright © 2010 Elsevier Ltd. All rights reserved.
Chen, Shao-Liang; Zhang, Jue-Jie; Han, Yaling; Kan, Jing; Chen, Lianglong; Qiu, Chunguang; Jiang, Tiemin; Tao, Ling; Zeng, Hesong; Li, Li; Xia, Yong; Gao, Chuanyu; Santoso, Teguh; Paiboon, Chootopol; Wang, Yan; Kwan, Tak W; Ye, Fei; Tian, Nailiang; Liu, Zhizhong; Lin, Song; Lu, Chengzhi; Wen, Shangyu; Hong, Lang; Zhang, Qi; Sheiban, Imad; Xu, Yawei; Wang, Lefeng; Rab, Tanveer S; Li, Zhanquan; Cheng, Guanchang; Cui, Lianqun; Leon, Martin B; Stone, Gregg W
2017-11-28
Provisional stenting (PS) is the most common technique used to treat distal left main (LM) bifurcation lesions in patients with unprotected LM coronary artery disease undergoing percutaneous coronary intervention. The double kissing (DK) crush planned 2-stent technique has been shown to improve clinical outcomes in non-LM bifurcations compared with PS, and in LM bifurcations compared with culotte stenting, but has never been compared with PS in LM bifurcation lesions. The authors sought to determine whether a planned DK crush 2-stent technique is superior to PS for patients with true distal LM bifurcation lesions. The authors randomized 482 patients from 26 centers in 5 countries with true distal LM bifurcation lesions (Medina 1,1,1 or 0,1,1) to PS (n = 242) or DK crush stenting (n = 240). The primary endpoint was the 1-year composite rate of target lesion failure (TLF): cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. Routine 13-month angiographic follow-up was scheduled after ascertainment of the primary endpoint. TLF within 1 year occurred in 26 patients (10.7%) assigned to PS, and in 12 patients (5.0%) assigned to DK crush (hazard ratio: 0.42; 95% confidence interval: 0.21 to 0.85; p = 0.02). Compared with PS, DK crush also resulted in lower rates of target vessel myocardial infarction I (2.9% vs. 0.4%; p = 0.03) and definite or probable stent thrombosis (3.3% vs. 0.4%; p = 0.02). Clinically driven target lesion revascularization (7.9% vs. 3.8%; p = 0.06) and angiographic restenosis within the LM complex (14.6% vs. 7.1%; p = 0.10) also tended to be less frequent with DK crush compared with PS. There was no significant difference in cardiac death between the groups. In the present multicenter randomized trial, percutaneous coronary intervention of true distal LM bifurcation lesions using a planned DK crush 2-stent strategy resulted in a lower rate of TLF at 1 year than a PS strategy. (Double Kissing and Double Crush Versus Provisional T Stenting Technique for the Treatment of Unprotected Distal Left Main True Bifurcation Lesions: A Randomized, International, Multi-Center Clinical Trial [DKCRUSH-V]; ChiCTR-TRC-11001213). Copyright © 2017 American College of Cardiology Foundation. All rights reserved.
de Matos Soeiro, Alexandre; de Almeida Soeiro, Maria Carolina Feres; de Oliveira, Mucio Tavares; Serrano, Carlos Viente
2014-11-01
Due to the chronic inflammation associated with systemic lupus erythematosus (SLE), patients develop premature atherosclerosis and the disease is a risk factor for acute myocardial infarction. The best interventional treatment for acute coronary syndrome (ACS) in these patients is unclear. The objective of this study is to describe the baseline characteristics, clinical manifestations, treatment and in-hospital outcome of patients with SLE and ACS. Eleven SLE patients with ACS were analyzed retrospectively between 2004 and 2011. The following data were obtained: age, gender, clinical and electrocardiographic characteristics, Killip class, risk factors for ACS, myocardial necrosis markers (CK-MB and troponin), creatinine clearance, left ventricular ejection fraction, inflammatory markers (C-reactive protein and erythrocyte sedimentation rate), drugs used during hospital stay, treatment (medical, percutaneous or surgical) and in-hospital outcome. The statistical analysis is presented in percentages and absolute values. Ten of the patients (91%) were women. The median age was 47 years. Typical precordial pain was present in 91%. Around 73% had positive erythrocyte sedimentation rate. The vessel most often affected was the anterior descending artery, in 73%. One patient underwent coronary artery bypass grafting, seven underwent percutaneous coronary intervention with bare-metal stents and three were treated medically. In-hospital mortality was 18%. Despite the small number of patients, our findings were similar to those in the literature, showing coronary artery disease in young people with SLE due to premature atherosclerosis and a high mortality rate. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.
Motion correction for improving the accuracy of dual-energy myocardial perfusion CT imaging
NASA Astrophysics Data System (ADS)
Pack, Jed D.; Yin, Zhye; Xiong, Guanglei; Mittal, Priya; Dunham, Simon; Elmore, Kimberly; Edic, Peter M.; Min, James K.
2016-03-01
Coronary Artery Disease (CAD) is the leading cause of death globally [1]. Modern cardiac computed tomography angiography (CCTA) is highly effective at identifying and assessing coronary blockages associated with CAD. The diagnostic value of this anatomical information can be substantially increased in combination with a non-invasive, low-dose, correlative, quantitative measure of blood supply to the myocardium. While CT perfusion has shown promise of providing such indications of ischemia, artifacts due to motion, beam hardening, and other factors confound clinical findings and can limit quantitative accuracy. In this paper, we investigate the impact of applying a novel motion correction algorithm to correct for motion in the myocardium. This motion compensation algorithm (originally designed to correct for the motion of the coronary arteries in order to improve CCTA images) has been shown to provide substantial improvements in both overall image quality and diagnostic accuracy of CCTA. We have adapted this technique for application beyond the coronary arteries and present an assessment of its impact on image quality and quantitative accuracy within the context of dual-energy CT perfusion imaging. We conclude that motion correction is a promising technique that can help foster the routine clinical use of dual-energy CT perfusion. When combined, the anatomical information of CCTA and the hemodynamic information from dual-energy CT perfusion should facilitate better clinical decisions about which patients would benefit from treatments such as stent placement, drug therapy, or surgery and help other patients avoid the risks and costs associated with unnecessary, invasive, diagnostic coronary angiography procedures.
Bioresorbable scaffolds for percutaneous coronary interventions
Gogas, Bill D.
2014-01-01
Innovations in drug-eluting stents (DES) have substantially reduced rates of in-segment restenosis and early stent thrombosis, improving clinical outcomes following percutaneous coronary interventions (PCI). However a fixed metallic implant in a vessel wall with restored patency and residual disease remains a precipitating factor for sustained local inflammation, in-stent neo-atherosclerosis and impaired vasomotor function increasing the risk for late complications attributed to late or very late stent thrombosis and late target lesion revascularization (TLR) (late catch-up). The quest for optimal coronary stenting continues by further innovations in stent design and by using biocompatible materials other than cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding, local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics have been recently developed. These devices have been utilized in selected clinical applications so far providing preliminary evidence of safety showing comparable performance with current generation drug-eluting stents (DES). Herein we provide a comprehensive overview of the current status of these technologies, we elaborate on the potential benefits of transient coronary scaffolds over permanent stents in the context of vascular reparation therapy, and we further focus on the evolving challenges these devices have to overcome to compete with current generation DES. Condensed Abstract:: The quest for optimizing percutaneous coronary interventions continues by iterative innovations in device materials beyond cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding; local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics were recently developed. These devices have been utilized in selected clinical applications providing preliminary evidence of safety showing comparable intermediate term clinical outcomes with current generation drug-eluting stents. PMID:25780795
Optimal Anticoagulant Therapy in ST Elevation Myocardial Infarction Interventions.
Oliveros, Estefania; Mehta, Sameer; Flores, Ana Isabel; Pena, Camilo; Cohen, Salomon; Kostela, Jennifer C; Rowen, Rebecca; Treto, Kevin
2012-10-01
Bivalirudin is a direct thrombin inhibitor. It is a new recommendation for the treatment of patients with ST-elevation myocardial infarction undergoing percutaneous coronary intervention. Bivalirudin combined with aspirin and P2Y 12 inhibitors has proved to be an effective and safe choice for the management of thrombus in coronary artery disease. The use of bivalirudin compared with the combination of heparin plus glycoprotein IIb/IIIa inhibitors as anticoagulant therapy is associated with reduced severe bleeding and inpatient mortality, as well as diminished costs. There is only a slight increase of late stent thrombosis, which may be controlled with the use of thienopyridines. Copyright © 2012 Elsevier Inc. All rights reserved.
Reczuch, Krzysztof; Jankowska, Ewa; Telichowski, Artur; Porada, Adam; Banasiak, Waldemar; Ponikowski, Piotr
2004-04-01
Patients with multi-vessel coronary artery disease (CAD) are selected for percutaneous coronary interventions (PCI) or surgical revascularisation. The appropriateness of "ad hoc" PCI of borderline lesions (<70% of lumen diameter) in patients with a multi-vessel CAD has not been proven. However, delayed PCI of another lesion and gaining additional information from non-invasive tests is not a widely accepted strategy. When left anterior descending (LAD) coronary artery is one of the affected vessels, selection for surgical revascularisation is most likely. To assess long-term outcome in patients with multi-vessel CAD and borderline lesions, including LAD, in whom fractional flow reserve (FFR) in all affected vessels was measured and used for selection for PCI or conservative treatment. The study group consisted of 16 patients with stable angina (11 males, mean age 60+/-9 years) with 34 lesions localised in the main epicardial coronary arteries [LAD / left main (LM) / right coronary artery (RCA) / intermediate branch (IB) / circumflex artery (Cx) - 15/1/5/5/8] of which at least two were borderline stenoses. Each lesion underwent FFR measurement. "Ad hoc" PCI was performed when FFR was <0.75, and conservative therapy was instituted when FFR was >0.75. Of 34 lesions, in 8 (23%) the FFR value was <0.75 and these lesions were treated with PCI (LAD/IB/Cx - 3/2/3). In the remaining 26 (77%) lesions, FFR was >0.75 and conservative therapy was instituted. During the mean follow-up of 15+/-6 months (range 6-28 months, median 15 months) in 8 of 9 conservatively treated patients no aggravation of anginal symptoms nor other coronary events were observed. One patient developed acute myocardial infarction due to thrombus occluding a borderline LAD lesion. Of 8 lesions treated with PCI (baseline FFR = 0.63+/-0.10 vs post-PCI FFR = 0.92+/-0.08, p=0.0002), in one case an in-stent restenosis in LAD occurred 9 months after PCI. Of a total of 26 lesions which were conservatively treated (mean FFR 0.91+/-0.05), in 2 (7.7%) the progression of CAD was noted. In patients with multi-vessel CAD and borderline lesions, FFR measurement identifies those, who can be treated conservatively with a good long-term outcome, and prevents unnecessary PCI.
Beijk, Marcel A.M.; Klomp, Margo; Verouden, Niels J.W.; van Geloven, Nan; Koch, Karel T.; Henriques, José P.S.; Baan, Jan; Vis, Marije M.; Scheunhage, Esther; Piek, Jan J.; Tijssen, Jan G.P.; de Winter, Robbert J.
2010-01-01
Aims The purpose of this study was to evaluate the GenousTM endothelial progenitor cell capturing stent vs. the Taxus Liberté paclitaxel-eluting stent in patients with de novo coronary lesions with a high-risk of coronary restenosis. Methods and results We randomly assigned 193 patients with lesions carrying a high risk of restenosis to have the Genous stent or the Taxus stent implanted. Lesions were considered high risk of restenosis if one of the following applied: chronic total occlusion, lesion length >23 mm, vessel diameter <2.8 mm, or any lesion in a diabetic patient. At 1-year, the rate of the primary end point, target vessel failure (TVF), was 17.3% in the Genous stent group when compared with 10.5% in the Taxus stent group [risk difference (RD) 6.8%, 95% CI −3.1 to 16.7%], a difference predominantly due to a higher incidence of repeat revascularization in patients treated with the Genous stent. In contrast, no stent thrombosis was observed in the Genous stent group compared to 4 stent thromboses in the Taxus stent group (RD −4.2%; 95% CI −10.3 to 0.3%). Repeat angiography between 6 and 12 months in a subgroup of patients showed a significantly higher late loss in the Genous stent compared with the Taxus stent (1.14 ± 0.64 and 0.55 ± 0.61 mm). Conclusion In patients with lesions carrying a high risk of restenosis, the Genous stent resulted in a non-significant higher rate of TVF compared with the Taxus stent mainly due to more repeat revascularizations in the Genous stent group. There were four stent thromboses with Taxus stent, none with the Genous stent. PMID:19933225
Multiplicity of morphologies in poly (l-lactide) bioresorbable vascular scaffolds
Ailianou, Artemis; Ramachandran, Karthik; Kossuth, Mary Beth; Oberhauser, James Paul; Kornfield, Julia A.
2016-01-01
Poly(l-lactide) (PLLA) is the structural material of the first clinically approved bioresorbable vascular scaffold (BVS), a promising alternative to permanent metal stents for treatment of coronary heart disease. BVSs are transient implants that support the occluded artery for 6 mo and are completely resorbed in 2 y. Clinical trials of BVSs report restoration of arterial vasomotion and elimination of serious complications such as late stent thrombosis. It is remarkable that a scaffold made from PLLA, known as a brittle polymer, does not fracture when crimped onto a balloon catheter or during deployment in the artery. We used X-ray microdiffraction to discover how PLLA acquired ductile character and found that the crimping process creates localized regions of extreme anisotropy; PLLA chains in the scaffold change orientation from the hoop direction to the radial direction on micrometer-scale distances. This multiplicity of morphologies in the crimped scaffold works in tandem to enable a low-stress response during deployment, which avoids fracture of the PLLA hoops and leaves them with the strength needed to support the artery. Thus, the transformations of the semicrystalline PLLA microstructure during crimping explain the unexpected strength and ductility of the current BVS and point the way to thinner resorbable scaffolds in the future. PMID:27671659
Antoine, Elizabeth E; Cornat, François P; Barakat, Abdul I
2016-12-01
Although vascular disease is a leading cause of mortality, in vitro tools for controlled, quantitative studies of vascular biological processes in an environment that reflects physiological complexity remain limited. We developed a novel in vitro artery that exhibits a number of unique features distinguishing it from tissue-engineered or organ-on-a-chip constructs, most notably that it allows deployment of endovascular devices including stents, quantitative real-time tracking of cellular responses and detailed measurement of flow velocity and lumenal shear stress using particle image velocimetry. The wall of the stentable in vitro artery consists of an annular collagen hydrogel containing smooth muscle cells (SMCs) and whose lumenal surface is lined with a monolayer of endothelial cells (ECs). The system has in vivo dimensions and physiological flow conditions and allows automated high-resolution live imaging of both SMCs and ECs. To demonstrate proof-of-concept, we imaged and quantified EC wound healing, SMC motility and altered shear stresses on the endothelium after deployment of a coronary stent. The stentable in vitro artery provides a unique platform suited for a broad array of research applications. Wide-scale adoption of this system promises to enhance our understanding of important biological events affecting endovascular device performance and to reduce dependence on animal studies. © 2016 The Author(s).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zelenak, Kamil, E-mail: zelenak@unm.sk; Zelenakova, Jana; DeRiggo, Julius
2011-12-15
Endovascular treatment for a wide-neck anterior communicating artery (AcomA) aneurysm remains technically challenging. Stent-assisted embolization has been proposed as an alternative of treatment of complex aneurysms. The X-configuration double-stent-assisted technique was used to achieve successful coiling of wide-neck AcomA aneurysm. Implanted stent can alter intra-arterial flow. Follow-up angiograms 4 months later showed flow changes due to used X-technique of stents implantation and filling of the anterior cerebral artery from the opposite internal carotid artery.
Double versus single stenting for coronary bifurcation lesions: a meta-analysis.
Katritsis, Demosthenes G; Siontis, George C M; Ioannidis, John P A
2009-10-01
Several trials have addressed whether bifurcation lesions require stenting of both the main vessel and side branch, but uncertainty remains on the benefits of such double versus single stenting of the main vessel only. We have conducted a meta-analysis of randomized trials including patients with coronary bifurcation lesions who were randomly selected to undergo percutaneous coronary intervention by either double or single stenting. Six studies (n=1642 patients) were eligible. There was increased risk of myocardial infarction with double stenting (risk ratio, 1.78; P=0.001 by fixed effects; risk ratio, 1.49 with Bayesian meta-analysis). The summary point estimate suggested also an increased risk of stent thrombosis with double stenting, but the difference was not nominally significant given the sparse data (risk ratio, 1.85; P=0.19). No obvious difference was seen for death (risk ratio, 0.81; P=0.66) and target lesion revascularization (risk ratio, 1.09; P=0.67). Stenting of both the main vessel and side branch in bifurcation lesions may increase myocardial infarction and stent thrombosis risk compared with stenting of the main vessel only.
Interaction of intraluminal tissue and coronary sinus lead stabilized with stent placement.
Balázs, Tibor; Merkely, Béla; Bognár, Eszter; Zima, Endre
2013-04-01
The aim of our investigation was to examine the intraluminal interaction of the vascular tissue and the implanted coronary sinus lead stabilized with stent on two human hearts removed before transplantation. The coronary sinus lumen was sectioned under operational microscope and opened carefully. The leads and stents were found separately positioned beside each other completely covered by an intact intimal tissue layer. No sign of occluding proliferative tissue was observed. Stent fixation technique and extraction of the CS lead in our cases did not have any particular damaging effect on the vascular system. © 2012 Wiley Periodicals, Inc.
Fan, Zhenmin; Liu, Xiao; Sun, Anqiang; Zhang, Nan; Fan, Zhanming; Fan, Yubo; Deng, Xiaoyan
2017-10-01
Longitudinal anatomic mismatch (LAM) of stenting (i.e., a stenotic artery segment is not fully covered by a deployed stent) worsens the mechanical environment in the treated artery, which most likely is the cause for the associated high risks of restenosis, myocardial infarction and stent thrombosis. To probe the possibility, we constructed a patient-specific carotid model with two components of plaques (lipid and calcified plaque) based on MRI images; we numerically compared three different stenting scenarios in terms of von Mises stress (VMS) distribution in the treated arteries, namely, the short stenting (LAM), the medium stenting and the long stenting. The results showed that the short stenting led to more areas with abnormally high VMS along the inner surface of the treated artery with a much higher surface-averaged VMS at the distal end of the stent than both the medium and long stenting. While the VMS distribution in the calcified plaques was similar for the three stenting models, it was quite different in the lipid plaques among the three stenting models. The lipid plaque of the short-stent model showed more volume of the lipid plaque subjected to high VMS than those of the other two models. Based on the obtained results, we may infer that the short stenting (i.e., LAM) may aggravate vascular injury due to high VMS on the artery-stent interaction surface and within the lipid plaque. Therefore, to obtain a better outcome, a longer stent, rather than a short one, might be needed for arterial stenting. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Retinal artery occlusion during carotid artery stenting with distal embolic protection device.
Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu
2018-01-01
Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.