Sample records for correct response rate

  1. The Utility of Maze Accurate Response Rate in Assessing Reading Comprehension in Upper Elementary and Middle School Students

    ERIC Educational Resources Information Center

    McCane-Bowling, Sara J.; Strait, Andrea D.; Guess, Pamela E.; Wiedo, Jennifer R.; Muncie, Eric

    2014-01-01

    This study examined the predictive utility of five formative reading measures: words correct per minute, number of comprehension questions correct, reading comprehension rate, number of maze correct responses, and maze accurate response rate (MARR). Broad Reading cluster scores obtained via the Woodcock-Johnson III (WJ III) Tests of Achievement…

  2. Method to determine the position-dependant metal correction factor for dose-rate equivalent laser testing of semiconductor devices

    DOEpatents

    Horn, Kevin M.

    2013-07-09

    A method reconstructs the charge collection from regions beneath opaque metallization of a semiconductor device, as determined from focused laser charge collection response images, and thereby derives a dose-rate dependent correction factor for subsequent broad-area, dose-rate equivalent, laser measurements. The position- and dose-rate dependencies of the charge-collection magnitude of the device are determined empirically and can be combined with a digital reconstruction methodology to derive an accurate metal-correction factor that permits subsequent absolute dose-rate response measurements to be derived from laser measurements alone. Broad-area laser dose-rate testing can thereby be used to accurately determine the peak transient current, dose-rate response of semiconductor devices to penetrating electron, gamma- and x-ray irradiation.

  3. Catatonia Education: Needs Assessment and Brief Online Intervention.

    PubMed

    Cooper, Joseph J; Roig Llesuy, Joan

    2017-06-01

    There are no studies investigating physicians' knowledge of catatonia. The authors aimed to assess and increase physicians' awareness of catatonia. A survey with clinical questions about catatonia was administered, followed by a brief online teaching module about catatonia and a post-education survey. Twenty-one psychiatry residents (response rate, 70%) and 36 internal medicine residents (response rate, 34%) participated in the pre-education survey. Psychiatry residents identified 75% of the correct answers about catatonia, compared to 32% correct by internal medicine residents (p < 0.001). Twenty participants (response rate, 35%) completed the online education module and second survey, which resulted in a significant improvement in correct response rates from 60 to 83% in all the participants (p < 0.001). Residents' baseline knowledge of catatonia is low, particularly among internal medicine residents. A brief online module improved resident physicians' knowledge of catatonia. Educational strategies to improve recognition of catatonia should be implemented.

  4. SU-E-T-472: Improvement of IMRT QA Passing Rate by Correcting Angular Dependence of MatriXX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Q; Watkins, W; Kim, T

    2015-06-15

    Purpose: Multi-channel planar detector arrays utilized for IMRT-QA, such as the MatriXX, exhibit an incident-beam angular dependent response which can Result in false-positive gamma-based QA results, especially for helical tomotherapy plans which encompass the full range of beam angles. Although MatriXX can use with gantry angle sensor to provide automatically angular correction, this sensor does not work with tomotherapy. The purpose of the study is to reduce IMRT-QA false-positives by correcting for the MatriXX angular dependence. Methods: MatriXX angular dependence was characterized by comparing multiple fixed-angle irradiation measurements with corresponding TPS computed doses. For 81 Tomo-helical IMRT-QA measurements, two differentmore » correction schemes were tested: (1) A Monte-Carlo dose engine was used to compute MatriXX signal based on the angular-response curve. The computed signal was then compared with measurement. (2) Uncorrected computed signal was compared with measurements uniformly scaled to account for the average angular dependence. Three scaling factor (+2%, +2.5%, +3%) were tested. Results: The MatriXX response is 8% less than predicted for a PA beam even when the couch is fully accounted for. Without angular correction, only 67% of the cases pass the >90% points γ<1 (3%, 3mm). After full angular correction, 96% of the cases pass the criteria. Of three scaling factors, +2% gave the highest passing rate (89%), which is still less than the full angular correction method. With a stricter γ(2%,3mm) criteria, the full angular correction method was still able to achieve the 90% passing rate while the scaling method only gives 53% passing rate. Conclusion: Correction for the MatriXX angular dependence reduced the false-positives rate of our IMRT-QA process. It is necessary to correct for the angular dependence to achieve the IMRT passing criteria specified in TG129.« less

  5. Combat Stress Decreases Memory of Warfighters in Action.

    PubMed

    Delgado-Moreno, Rosa; Robles-Pérez, José Juan; Clemente-Suárez, Vicente Javier

    2017-08-01

    The present research aimed to analyze the effect of combat stress in the psychophysiological response and attention and memory of warfighters in a simulated combat situation. Variables of blood oxygen saturation, heart rate, blood glucose, blood lactate, body temperature, lower body muscular strength manifestation, cortical arousal, autonomic modulation, state anxiety and memory and attention through a postmission questionnaire were analyzed before and after a combat simulation in 20 male professional Spanish Army warfighters. The combat simulation produces a significant increase (p < 0.05) in explosive leg strength, rated perceived exertion, blood glucose, blood lactate, somatic anxiety, heart rate, and low frequency domain of the HRV (LF) and a significant decrease of high frequency domain of the heart rate variability (HF). The percentage of correct response in the postmission questionnaire parameters show that elements more related with a physical integrity threat are the most correctly remembered. There were significant differences in the postmission questionnaire variables when participants were divided by the cortical arousal post: sounds no response, mobile phone correct, mobile phone no response, odours correct. The correlation analysis showed positive correlations: LF post/body temperature post, HF post/correct sound, body temperature post/glucose post, CFFTpre/lactate post, CFFT post/wrong sound, glucose post/AC pre, AC post/wrong fusil, AS post/SC post and SC post/wrong olfactory; and negative correlations: LF post/correct sound, body temperature post/lactate post and glucose post/lactate post. This data suggest that combat stress actives fight-flight system of soldiers. As conclusion, Combat stress produces an increased psychophysiological response that cause a selective decrease of memory, depending on the nature, dangerous or harmless of the objects.

  6. An evaluation of some pertinent parameters that influence the dosimetric performance of synthetic diamond detectors

    NASA Astrophysics Data System (ADS)

    Ade, N.; Nam, T. L.; Mhlanga, S. H.

    2013-05-01

    Although the near-tissue equivalence of diamond allows the direct measurement of dose for clinical applications without the need for energy-corrections, it is often cited that diamond detectors require pre-irradiation, a procedure necessary to stabilize the response or sensitivity of a diamond detector before dose measurements. In addition it has been pointed out that the relative dose measured with a diamond detector requires dose rate dependence correction and that the angular dependence of a detector could be due to its mechanical design or to the intrinsic angular sensitivity of the detection process. While the cause of instability of response has not been meticulously investigated, the issue of dose rate dependence correction is uncertain as some studies ignored it but reported good results. The aims of this study were therefore to investigate, in particular (1) the major cause of the unstable response of diamond detectors requiring pre-irradiation; (2) the influence of dose rate dependence correction in relative dose measurements; and (3) the angular dependence of the diamond detectors. The study was conducted with low-energy X-rays and electron therapy beams on HPHT and CVD synthesized diamonds. Ionization chambers were used for comparative measurements. Through systematic investigations, the major cause of the unstable response of diamond detectors requiring the recommended pre-irradiation step was isolated and attributed to the presence and effects of ambient light. The variation in detector's response between measurements in light and dark conditions could be as high as 63% for a CVD diamond. Dose rate dependence parameters (Δ values) of 0.950 and 1.035 were found for the HPHT and CVD diamond detectors, respectively. Without corrections based on dose rate dependence, the relative differences between depth-doses measured with the diamond detectors and a Markus chamber for exposures to 7 and 14 MeV electron beams were within 2.5%. A dose rate dependence correction using the Δ values obtained seemed to worsen the performance of the HPHT sample (up to about 3.3%) but it had a marginal effect on the performance of the CVD sample. In addition, the angular response of the CVD diamond detector was shown to be comparable with that of a cylindrical chamber. This study concludes that once the responses of the diamond detectors have been stabilised and they are properly shielded from ambient light, pre-irradiation prior to each measurement is not required. Also, the relative dose measured with the diamond detectors do not require dose rate dependence corrections as the required correction is only marginal and could have no dosimetric significance.

  7. Deficits in allergy knowledge among physicians at academic medical centers.

    PubMed

    Stukus, David R; Green, Todd; Montandon, Shari V; Wada, Kara J

    2015-07-01

    Allergic conditions have high prevalence in the general population. Misconceptions regarding the diagnosis and management of allergic disease among physicians can lead to suboptimal clinical care. To determine the extent of allergy-related knowledge deficits among physicians. Pediatric and internal medicine resident and attending physicians from 2 separate academic medical centers were asked to answer an anonymous electronic survey. Survey questions addressed 7 different allergy content areas. Four hundred eight physicians completed surveys (23.9% response rate). Respondents had few correct answers (mean ± SD 1.91 ± 1.43). Pediatric respondents had a larger number of correct answers compared with medicine-trained physicians (P < .001). No individual answered every survey question correctly, and 50 respondents (12.3%) had no correct answer. Three hundred seventy-eight respondents (92.6%) were unable to provide correct answers for at least 50% of survey questions. Level of residency training and prior rotation through an allergy and immunology elective correlated with a larger number of correct responses (P < .01). Only 1 survey question had an overall correct response rate higher than 50% (n = 261, 64%). Correct response rate was lower than 30% for 7 of the 9 possible questions. There are significant knowledge deficits in many areas of allergy-related content among pediatric and internal medicine physicians and across all levels of training and specialty. Given the prevalence of allergic conditions, the potential implications of a negative impact on clinical care are staggering. Copyright © 2015 American College of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  8. Respiratory sinus arrhythmia responses to induced emotional states: effects of RSA indices, emotion induction method, age, and sex.

    PubMed

    Overbeek, Thérèse J M; van Boxtel, Anton; Westerink, Joyce H D M

    2012-09-01

    The literature shows large inconsistencies in respiratory sinus arrhythmia (RSA) responses to induced emotional states. This may be caused by differences in emotion induction methods, RSA quantification, and non-emotional demands of the situation. In 83 healthy subjects, we studied RSA responses to pictures and film fragments eliciting six different discrete emotions relative to neutral baseline stimuli. RSA responses were quantified in the time and frequency domain and were additionally corrected for differences in mean heart rate and respiration rate, resulting in eight different RSA response measures. Subjective ratings of emotional stimuli and facial electromyographic responses indicated that pictures and film fragments elicited the intended emotions. Although RSA measures showed various emotional effects, responses were quite heterogeneous and frequently nonsignificant. They were substantially influenced by methodological factors, in particular time vs. frequency domain response measures, correction for changes in respiration rate, use of pictures vs. film fragments, and sex of participants. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Technical Adequacy of Response to Intervention Decisions

    ERIC Educational Resources Information Center

    VanDerHeyden, Amanda M.

    2011-01-01

    Perhaps the greatest value of response to intervention (RTI) as a decision framework is that it brings attention to variables (e.g., mastery of prerequisite skills, frequency of instructional corrective feedback, reinforcement schedules for correct responding) that if changed might make a meaningful difference for students (e.g., child rate of…

  10. Delay time correction of the gas analyzer in the calculation of anatomical dead space of the lung.

    PubMed

    Okubo, T; Shibata, H; Takishima, T

    1983-07-01

    By means of a mathematical model, we have studied a way to correct the delay time of the gas analyzer in order to calculate the anatomical dead space using Fowler's graphical method. The mathematical model was constructed of ten tubes of equal diameter but unequal length, so that the amount of dead space varied from tube to tube; the tubes were emptied sequentially. The gas analyzer responds with a time lag from the input of the gas signal to the beginning of the response, followed by an exponential response output. The single breath expired volume-concentration relationship was examined with three types of expired flow patterns of which were constant, exponential and sinusoidal. The results indicate that the time correction by the lag time plus time constant of the exponential response of the gas analyzer gives an accurate estimation of anatomical dead space. Time correction less inclusive than this, e.g. lag time only or lag time plus 50% response time, gives an overestimation, and a correction larger than this results in underestimation. The magnitude of error is dependent on the flow pattern and flow rate. The time correction in this study is only for the calculation of dead space, as the corrected volume-concentration curves does not coincide with the true curve. Such correction of the output of the gas analyzer is extremely important when one needs to compare the dead spaces of different gas species at a rather faster flow rate.

  11. [Evaluation, correction and impact of non-response in studies of childhood obesity].

    PubMed

    Santiago-Pérez, María Isolina; Pérez-Ríos, Mónica; Malvar, Alberto; Suanzes, Jorge; Hervada, Xurxo

    2017-09-25

    To evaluate and correct the impact of non-response in the prevalence of underweight, overweight and obesity in children aged 6 to 15 years old using silhouette scales. Cross-sectional study carried out in 2013 among 8,145 Galician schoolchildren aged 6-15 years old. The students who agreed to participate were weighed and measured and, based on body mass index, the prevalence of underweight, overweight and obesity was estimated. Teachers rated all students using silhouette scales. The valuations were used to estimate the prevalence corrected by non-response. Using the Bayes theorem, participation rates were estimated according to weight status. The participation rate was 92.3% in the 6 -to 11-year-old group, and 90% in the 12- to 15-year old age group. In both groups, the prevalence of underweight and overweight were similar between participants and non-participants. However, obesity was higher among non-participants, especially at 12 to 15 years of age (6.3% vs. 12.2% ; p < 0.05). The prevalence did not change when corrected by the teacher's valuation. The participation rate of obese students was lower than the overall rate (82% vs. 90% at 12 to 15 years old; p < 0.05). The presence of participation bias, which was greater at 12-15 years old, was confirmed. However, the impact of the bias on prevalence was negligible due to the high participation rate. In obesity studies with objective measures, it is essential to quantify non-participation, as well as to assess its impact and correct it. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Reward rate optimization in two-alternative decision making: empirical tests of theoretical predictions.

    PubMed

    Simen, Patrick; Contreras, David; Buck, Cara; Hu, Peter; Holmes, Philip; Cohen, Jonathan D

    2009-12-01

    The drift-diffusion model (DDM) implements an optimal decision procedure for stationary, 2-alternative forced-choice tasks. The height of a decision threshold applied to accumulating information on each trial determines a speed-accuracy tradeoff (SAT) for the DDM, thereby accounting for a ubiquitous feature of human performance in speeded response tasks. However, little is known about how participants settle on particular tradeoffs. One possibility is that they select SATs that maximize a subjective rate of reward earned for performance. For the DDM, there exist unique, reward-rate-maximizing values for its threshold and starting point parameters in free-response tasks that reward correct responses (R. Bogacz, E. Brown, J. Moehlis, P. Holmes, & J. D. Cohen, 2006). These optimal values vary as a function of response-stimulus interval, prior stimulus probability, and relative reward magnitude for correct responses. We tested the resulting quantitative predictions regarding response time, accuracy, and response bias under these task manipulations and found that grouped data conformed well to the predictions of an optimally parameterized DDM.

  13. Deep Belief Networks Learn Context Dependent Behavior

    PubMed Central

    Raudies, Florian; Zilli, Eric A.; Hasselmo, Michael E.

    2014-01-01

    With the goal of understanding behavioral mechanisms of generalization, we analyzed the ability of neural networks to generalize across context. We modeled a behavioral task where the correct responses to a set of specific sensory stimuli varied systematically across different contexts. The correct response depended on the stimulus (A,B,C,D) and context quadrant (1,2,3,4). The possible 16 stimulus-context combinations were associated with one of two responses (X,Y), one of which was correct for half of the combinations. The correct responses varied symmetrically across contexts. This allowed responses to previously unseen stimuli (probe stimuli) to be generalized from stimuli that had been presented previously. By testing the simulation on two or more stimuli that the network had never seen in a particular context, we could test whether the correct response on the novel stimuli could be generated based on knowledge of the correct responses in other contexts. We tested this generalization capability with a Deep Belief Network (DBN), Multi-Layer Perceptron (MLP) network, and the combination of a DBN with a linear perceptron (LP). Overall, the combination of the DBN and LP had the highest success rate for generalization. PMID:24671178

  14. Do former preterm infants remember and respond to neonatal intensive care unit noise?

    PubMed

    Barreto, Edwin D; Morris, Brenda H; Philbin, M Kathleen; Gray, Lincoln C; Lasky, Robert E

    2006-11-01

    Previous studies have shown that 4-month-old infants have a decrease in heart rate, a component of the orienting reflex, in response to interesting auditory stimuli and an increase in heart rate to aversive auditory stimuli. To compare the heart rate responses of former preterm and term infants at 4-5 months corrected age to a recording of NICU noises. 13 former preterm infants and 17 full-term infants were presented NICU noise and another noise of similar level and frequency content in random order. Heart rate 10s prior to the stimulus and for 20s during the stimulus was analyzed. Group differences in second by second heart rate changes in response to the two noise stimuli were compared by analysis of covariance. Both the preterm and term newborns responded similarly to the NICU noise and the control noise. The preterm infants did not alter their heart rate in response to either stimulus. In contrast, the term infants displayed an orienting response to the second stimulus presented regardless of whether it was the NICU or control noise. Former preterm infants at 4-5 months corrected age have reduced responsiveness to auditory stimulation in comparison to 4- to 5-month-old term infants. Furthermore, they did not respond to the NICU noise as an aversive stimulus.

  15. Response time of mitochondrial oxygen consumption following stepwise changes in cardiac energy demand.

    PubMed

    van Beek, J H; Westerhof, N

    1990-01-01

    We determined the speed with which mitochondrial oxygen consumption and therefore the mitochondrial ATP-synthesis adapted to changes in metabolic demand in the rabbit heart. This was done by measuring the oxygen uptake of the whole heart during a stepwise change in heart rate and correcting for the time taken by diffusion and by convective transport in the blood vessels. Data for the correction for transport time were obtained from the response of venous oxygen concentration to a stepwise change of arterial oxygen concentration. The time constant of the response of mitochondrial oxygen consumption to a step change in heart rate was found to be 4-8 s.

  16. Dose-to-water conversion for the backscatter-shielded EPID: A frame-based method to correct for EPID energy response to MLC transmitted radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zwan, Benjamin J., E-mail: benjamin.zwan@uon.edu.au; O’Connor, Daryl J.; King, Brian W.

    2014-08-15

    Purpose: To develop a frame-by-frame correction for the energy response of amorphous silicon electronic portal imaging devices (a-Si EPIDs) to radiation that has transmitted through the multileaf collimator (MLC) and to integrate this correction into the backscatter shielded EPID (BSS-EPID) dose-to-water conversion model. Methods: Individual EPID frames were acquired using a Varian frame grabber and iTools acquisition software then processed using in-house software developed inMATLAB. For each EPID image frame, the region below the MLC leaves was identified and all pixels in this region were multiplied by a factor of 1.3 to correct for the under-response of the imager tomore » MLC transmitted radiation. The corrected frames were then summed to form a corrected integrated EPID image. This correction was implemented as an initial step in the BSS-EPID dose-to-water conversion model which was then used to compute dose planes in a water phantom for 35 IMRT fields. The calculated dose planes, with and without the proposed MLC transmission correction, were compared to measurements in solid water using a two-dimensional diode array. Results: It was observed that the integration of the MLC transmission correction into the BSS-EPID dose model improved agreement between modeled and measured dose planes. In particular, the MLC correction produced higher pass rates for almost all Head and Neck fields tested, yielding an average pass rate of 99.8% for 2%/2 mm criteria. A two-sample independentt-test and fisher F-test were used to show that the MLC transmission correction resulted in a statistically significant reduction in the mean and the standard deviation of the gamma values, respectively, to give a more accurate and consistent dose-to-water conversion. Conclusions: The frame-by-frame MLC transmission response correction was shown to improve the accuracy and reduce the variability of the BSS-EPID dose-to-water conversion model. The correction may be applied as a preprocessing step in any pretreatment portal dosimetry calculation and has been shown to be beneficial for highly modulated IMRT fields.« less

  17. 78 FR 75484 - Federal Management Regulation (FMR); Shipping Household Goods

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-12

    ... information on the commuted rate schedule and correct a Web site address. Commuted rate and actual expense are... commuted rate method. Using the commuted rate method, the individual assumes responsibility for shipment and payment. The commuted rate schedule establishes the reimbursement rate. DATES: Effective Date...

  18. How well are we preparing pediatricians to manage seizures and epilepsy? A single-center questionnaire-based pilot study.

    PubMed

    Agarwal, Rajkumar L; Agarwal, Roshani R; Sivaswamy, Lalitha

    2014-06-01

    To assess the knowledge of pediatric residents regarding principles of management of seizures and epilepsy. A 10-item multiple-choice questionnaire with single correct response each (scored as 1) was administered to pediatric residents at an academic hospital. Out of 92 questionnaires, 73 were returned (79.3%). The mean score was 5 ± 1.9 (range = 1 to 9). Most correct responses (53/70, 75.5%) were received for the question on diagnosis of epilepsy. Questions on febrile seizures and on pharmacology of valproic acid received <50% correct responses among senior as well as junior residents, with no significant improvement in the correct response rate of senior residents. Deficiencies exist in pediatric residents' knowledge of seizures and epilepsy, especially with respect to febrile seizures and pharmacology of antiepileptic medications. Improved mechanisms to promote understanding in these areas are needed during pediatric training. © The Author(s) 2014.

  19. The Effects of Observation of Learn Units during Reinforcement and Correction Conditions on the Rate of Learning Math Algorithms by Fifth Grade Students

    ERIC Educational Resources Information Center

    Neu, Jessica Adele

    2013-01-01

    I conducted two studies on the comparative effects of the observation of learn units during (a) reinforcement or (b) correction conditions on the acquisition of math objectives. The dependent variables were the within-session cumulative numbers of correct responses emitted during observational sessions. The independent variables were the…

  20. A two-phase sampling survey for nonresponse and its paradata to correct nonresponse bias in a health surveillance survey.

    PubMed

    Santin, G; Bénézet, L; Geoffroy-Perez, B; Bouyer, J; Guéguen, A

    2017-02-01

    The decline in participation rates in surveys, including epidemiological surveillance surveys, has become a real concern since it may increase nonresponse bias. The aim of this study is to estimate the contribution of a complementary survey among a subsample of nonrespondents, and the additional contribution of paradata in correcting for nonresponse bias in an occupational health surveillance survey. In 2010, 10,000 workers were randomly selected and sent a postal questionnaire. Sociodemographic data were available for the whole sample. After data collection of the questionnaires, a complementary survey among a random subsample of 500 nonrespondents was performed using a questionnaire administered by an interviewer. Paradata were collected for the complete subsample of the complementary survey. Nonresponse bias in the initial sample and in the combined samples were assessed using variables from administrative databases available for the whole sample, not subject to differential measurement errors. Corrected prevalences by reweighting technique were estimated by first using the initial survey alone and then the initial and complementary surveys combined, under several assumptions regarding the missing data process. Results were compared by computing relative errors. The response rates of the initial and complementary surveys were 23.6% and 62.6%, respectively. For the initial and the combined surveys, the relative errors decreased after correction for nonresponse on sociodemographic variables. For the combined surveys without paradata, relative errors decreased compared with the initial survey. The contribution of the paradata was weak. When a complex descriptive survey has a low response rate, a short complementary survey among nonrespondents with a protocol which aims to maximize the response rates, is useful. The contribution of sociodemographic variables in correcting for nonresponse bias is important whereas the additional contribution of paradata in correcting for nonresponse bias is questionable. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Measuring Response Styles Across the Big Five: A Multiscale Extension of an Approach Using Multinomial Processing Trees.

    PubMed

    Khorramdel, Lale; von Davier, Matthias

    2014-01-01

    This study shows how to address the problem of trait-unrelated response styles (RS) in rating scales using multidimensional item response theory. The aim is to test and correct data for RS in order to provide fair assessments of personality. Expanding on an approach presented by Böckenholt (2012), observed rating data are decomposed into multiple response processes based on a multinomial processing tree. The data come from a questionnaire consisting of 50 items of the International Personality Item Pool measuring the Big Five dimensions administered to 2,026 U.S. students with a 5-point rating scale. It is shown that this approach can be used to test if RS exist in the data and that RS can be differentiated from trait-related responses. Although the extreme RS appear to be unidimensional after exclusion of only 1 item, a unidimensional measure for the midpoint RS is obtained only after exclusion of 10 items. Both RS measurements show high cross-scale correlations and item response theory-based (marginal) reliabilities. Cultural differences could be found in giving extreme responses. Moreover, it is shown how to score rating data to correct for RS after being proved to exist in the data.

  2. Weathering effects on fuel moisture sticks: corrections and recommendations.

    Treesearch

    Donald A. Haines; John S. Frost

    1978-01-01

    Describes response to weathering of 100-gram (1/2-inch) fuel moisture sticks over 6-month fire season in the Northeast. Presents a chart for correcting weathered-stick values and gives replacement recommendations for those sticks used in the National Fire Danger Rating System.

  3. Diagnosis of complex acid-base disorders: physician performance versus the microcomputer.

    PubMed

    Schreck, D M; Zacharias, D; Grunau, C F

    1986-02-01

    Patients with acid-base disturbances that are often complex frequently present to the emergency department. The sometimes hectic nature of the ED can preclude the appropriate quantitative analysis required by these disorders, especially when mixed disturbances are present. A computer program using generally accepted acid-base and electrolyte formulae was developed for use on the Apple II+ or IBM-PC microcomputer. Each of a series of 35 acid-base disturbances incorporating single, double, and triple disorders was correctly identified by the computer in less than 45 seconds. Problem sets based on the same 35 disturbances were presented to 21 physician-subjects at various levels of training from the emergency medicine, internal medicine, pediatrics, surgery, and family practice specialties. Although the physicians were given unlimited time and the necessary formulae to reach a diagnosis, they were requested to perform their analyses in the same fashion used in the ED. Although times varied widely, no physician spent more than five minutes on any problem. The physician correct response rates were 86%, 49%, and 17% for single, double, and triple disorders, respectively. The primary disorder correct response rate was 89% for double disorders and 94% for triple disorders. The primary and secondary disorder correct response rate was 58% for triple disorders. The data suggest that the microcomputer may be beneficial in the rapid assessment of complex disorders.

  4. A comparative study of the effects of cone-plate and parallel-plate geometries on rheological properties under oscillatory shear flow

    NASA Astrophysics Data System (ADS)

    Song, Hyeong Yong; Salehiyan, Reza; Li, Xiaolei; Lee, Seung Hak; Hyun, Kyu

    2017-11-01

    In this study, the effects of cone-plate (C/P) and parallel-plate (P/P) geometries were investigated on the rheological properties of various complex fluids, e.g. single-phase (polymer melts and solutions) and multiphase systems (polymer blend and nanocomposite, and suspension). Small amplitude oscillatory shear (SAOS) tests were carried out to compare linear rheological responses while nonlinear responses were compared using large amplitude oscillatory shear (LAOS) tests at different frequencies. Moreover, Fourier-transform (FT)-rheology method was used to analyze the nonlinear responses under LAOS flow. Experimental results were compared with predictions obtained by single-point correction and shear rate correction. For all systems, SAOS data measured by C/P and P/P coincide with each other, but results showed discordance between C/P and P/P measurements in the nonlinear regime. For all systems except xanthan gum solutions, first-harmonic moduli were corrected using a single horizontal shift factor, whereas FT rheology-based nonlinear parameters ( I 3/1, I 5/1, Q 3, and Q 5) were corrected using vertical shift factors that are well predicted by single-point correction. Xanthan gum solutions exhibited anomalous corrections. Their first-harmonic Fourier moduli were superposed using a horizontal shift factor predicted by shear rate correction applicable to highly shear thinning fluids. The distinguished corrections were observed for FT rheology-based nonlinear parameters. I 3/1 and I 5/1 were superposed by horizontal shifts, while the other systems displayed vertical shifts of I 3/1 and I 5/1. Q 3 and Q 5 of xanthan gum solutions were corrected using both horizontal and vertical shift factors. In particular, the obtained vertical shift factors for Q 3 and Q 5 were twice as large as predictions made by single-point correction. Such larger values are rationalized by the definitions of Q 3 and Q 5. These results highlight the significance of horizontal shift corrections in nonlinear oscillatory shear data.

  5. Reaction Time and Accuracy in Erroneous vs Correct Responses among Dyslexic and Regular Readers: From Letters to Sentences

    ERIC Educational Resources Information Center

    Horowitz-Kraus, Tzipi; Breznitz, Zvia

    2011-01-01

    Speed of processing (SOP) is a crucial factor in fluent reading and is measured using reading rate. This measure is commonly used to examine correct reading patterns, yet in the present study it is employed to determine whether differences in SOP exist for correct and incorrect reading. One of the characteristics of dyslexia is slow and inaccurate…

  6. Correct acceptance weighs more than correct rejection: a decision bias induced by question framing.

    PubMed

    Kareev, Yaakov; Trope, Yaacov

    2011-02-01

    We propose that in attempting to detect whether an effect exists or not, people set their decision criterion so as to increase the number of hits and decrease the number of misses, at the cost of increasing false alarms and decreasing correct rejections. As a result, we argue, if one of two complementary events is framed as the positive response to a question and the other as the negative response, people will tend to predict the former more often than the latter. Performance in a prediction task with symmetric payoffs and equal base rates supported our proposal. Positive responses were indeed more prevalent than negative responses, irrespective of the phrasing of the question. The bias, slight but consistent and significant, was evident from early in a session and then remained unchanged to the end. A regression analysis revealed that, in addition, individuals' decision criteria reflected their learning experiences, with the weight of hits being greater than that of correct rejections.

  7. Work-family conflict and job burnout among correctional staff.

    PubMed

    Lambert, Eric G; Hogan, Nancy L

    2010-02-01

    Work-family conflict and job burnout are both issues for 272 correctional staff (response rate of 68%). The two major forms of work-family conflict are work-on-family conflict and family-on-work conflict. Multivariate analysis of survey data from 272 correctional staff at a state prison indicated work-on-family conflict had a significant positive relation with job burnout, while family-on-work conflict did not.

  8. Cerebral responses to innocuous somatic pressure stimulation following aerobic exercise rehabilitation in chronic pain patients: a functional magnetic resonance imaging study

    PubMed Central

    Micalos, Peter S; Korgaonkar, Mayuresh S; Drinkwater, Eric J; Cannon, Jack; Marino, Frank E

    2014-01-01

    Objective The purpose of this research was to assess the functional brain activity and perceptual rating of innocuous somatic pressure stimulation before and after exercise rehabilitation in patients with chronic pain. Materials and methods Eleven chronic pain patients and eight healthy pain-free controls completed 12 weeks of supervised aerobic exercise intervention. Perceptual rating of standardized somatic pressure stimulation (2 kg) on the right anterior mid-thigh and brain responses during functional magnetic resonance imaging (fMRI) were assessed at pre- and postexercise rehabilitation. Results There was a significant difference in the perceptual rating of innocuous somatic pressure stimulation between the chronic pain and control groups (P=0.02) but no difference following exercise rehabilitation. Whole brain voxel-wise analysis with correction for multiple comparisons revealed trends for differences in fMRI responses between the chronic pain and control groups in the superior temporal gyrus (chronic pain > control, corrected P=0.30), thalamus, and caudate (control > chronic, corrected P=0.23). Repeated measures of the regions of interest (5 mm radius) for blood oxygen level-dependent signal response revealed trend differences for superior temporal gyrus (P=0.06), thalamus (P=0.04), and caudate (P=0.21). Group-by-time interactions revealed trend differences in the caudate (P=0.10) and superior temporal gyrus (P=0.29). Conclusion Augmented perceptual and brain responses to innocuous somatic pressure stimulation were shown in the chronic pain group compared to the control group; however, 12-weeks of exercise rehabilitation did not significantly attenuate these responses. PMID:25210471

  9. Vertex evoked potentials in a rating-scale detection task: Relation to signal probability

    NASA Technical Reports Server (NTRS)

    Squires, K. C.; Squires, N. K.; Hillyard, S. A.

    1974-01-01

    Vertex evoked potentials were recorded from human subjects performing in an auditory detection task with rating scale responses. Three values of a priori probability of signal presentation were tested. The amplitudes of the N1 and P3 components of the vertex potential associated with correct detections of the signal were found to be systematically related to the strictness of the response criterion and independent of variations in a priori signal probability. No similar evoked potential components were found associated with signal absent judgements (misses and correct rejections) regardless of the confidence level of the judgement or signal probability. These results strongly support the contention that the form of the vertex evoked response is closely correlated with the subject's psychophysical decision regarding the presence or absence of a threshold level signal.

  10. Frequency of under-corrected refractive errors in elderly Chinese in Beijing.

    PubMed

    Xu, Liang; Li, Jianjun; Cui, Tongtong; Tong, Zhongbiao; Fan, Guizhi; Yang, Hua; Sun, Baochen; Zheng, Yuanyuan; Jonas, Jost B

    2006-07-01

    The aim of the study was to evaluate the prevalence of under-corrected refractive error among elderly Chinese in the Beijing area. The population-based, cross-sectional, cohort study comprised 4,439 subjects out of 5,324 subjects asked to participate (response rate 83.4%) with an age of 40+ years. It was divided into a rural part [1,973 (44.4%) subjects] and an urban part [2,466 (55.6%) subjects]. Habitual and best-corrected visual acuity was measured. Under-corrected refractive error was defined as an improvement in visual acuity of the better eye of at least two lines with best possible refractive correction. The rate of under-corrected refractive error was 19.4% (95% confidence interval, 18.2, 20.6). In a multiple regression analysis, prevalence and size of under-corrected refractive error in the better eye was significantly associated with lower level of education (P<0.001), female gender (P<0.001), and age (P=0.001). Under-correction of refractive error is relatively common among elderly Chinese in the Beijing area when compared with data from other populations.

  11. How automatic is the hand's automatic pilot? Evidence from dual-task studies.

    PubMed

    McIntosh, Robert D; Mulroue, Amy; Brockmole, James R

    2010-10-01

    The ability to correct reaching movements for changes in target position has been described as the hand's 'automatic pilot'. These corrections are preconscious and occur by default in double-step reaching tasks, even if the goal is to react to the target jump in some other way, for instance by stopping the movement (STOP instruction). Nonetheless, corrections are strongly modulated by conscious intention: participants make more corrections when asked to follow the target (GO instruction) and can suppress them when explicitly asked not to follow the target (NOGO instruction). We studied the influence of a cognitively demanding (auditory 1-back) task upon correction behaviour under GO, STOP and NOGO instructions. Correction rates under the STOP instruction were unaffected by cognitive load, consistent with the assumption that they reflect the default behaviour of the automatic pilot. Correction rates under the GO instruction were also unaffected, suggesting that minimal cognitive resources are required to enhance online correction. By contrast, cognitive load impeded the ability to suppress online corrections under the NOGO instruction. These data reveal a constitutional bias in the automatic pilot system: intentional suppression of the default correction behaviour is cognitively demanding, but enhancement towards greater responsiveness is seemingly effortless.

  12. Item response theory scoring and the detection of curvilinear relationships.

    PubMed

    Carter, Nathan T; Dalal, Dev K; Guan, Li; LoPilato, Alexander C; Withrow, Scott A

    2017-03-01

    Psychologists are increasingly positing theories of behavior that suggest psychological constructs are curvilinearly related to outcomes. However, results from empirical tests for such curvilinear relations have been mixed. We propose that correctly identifying the response process underlying responses to measures is important for the accuracy of these tests. Indeed, past research has indicated that item responses to many self-report measures follow an ideal point response process-wherein respondents agree only to items that reflect their own standing on the measured variable-as opposed to a dominance process, wherein stronger agreement, regardless of item content, is always indicative of higher standing on the construct. We test whether item response theory (IRT) scoring appropriate for the underlying response process to self-report measures results in more accurate tests for curvilinearity. In 2 simulation studies, we show that, regardless of the underlying response process used to generate the data, using the traditional sum-score generally results in high Type 1 error rates or low power for detecting curvilinearity, depending on the distribution of item locations. With few exceptions, appropriate power and Type 1 error rates are achieved when dominance-based and ideal point-based IRT scoring are correctly used to score dominance and ideal point response data, respectively. We conclude that (a) researchers should be theory-guided when hypothesizing and testing for curvilinear relations; (b) correctly identifying whether responses follow an ideal point versus dominance process, particularly when items are not extreme is critical; and (c) IRT model-based scoring is crucial for accurate tests of curvilinearity. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Real-time distortion correction of spiral and echo planar images using the gradient system impulse response function.

    PubMed

    Campbell-Washburn, Adrienne E; Xue, Hui; Lederman, Robert J; Faranesh, Anthony Z; Hansen, Michael S

    2016-06-01

    MRI-guided interventions demand high frame rate imaging, making fast imaging techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study, we implemented a real-time distortion correction framework to enable the use of these fast acquisitions for interventional MRI. Distortions caused by gradient waveform inaccuracies were corrected using the gradient impulse response function (GIRF), which was measured by standard equipment and saved as a calibration file on the host computer. This file was used at runtime to calculate the predicted k-space trajectories for image reconstruction. Additionally, the off-resonance reconstruction frequency was modified in real time to interactively deblur spiral images. Real-time distortion correction for arbitrary image orientations was achieved in phantoms and healthy human volunteers. The GIRF-predicted k-space trajectories matched measured k-space trajectories closely for spiral imaging. Spiral and EPI image distortion was visibly improved using the GIRF-predicted trajectories. The GIRF calibration file showed no systematic drift in 4 months and was demonstrated to correct distortions after 30 min of continuous scanning despite gradient heating. Interactive off-resonance reconstruction was used to sharpen anatomical boundaries during continuous imaging. This real-time distortion correction framework will enable the use of these high frame rate imaging methods for MRI-guided interventions. Magn Reson Med 75:2278-2285, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  14. Real-time distortion correction of spiral and echo planar images using the gradient system impulse response function

    PubMed Central

    Campbell-Washburn, Adrienne E; Xue, Hui; Lederman, Robert J; Faranesh, Anthony Z; Hansen, Michael S

    2015-01-01

    Purpose MRI-guided interventions demand high frame-rate imaging, making fast imaging techniques such as spiral imaging and echo planar imaging (EPI) appealing. In this study, we implemented a real-time distortion correction framework to enable the use of these fast acquisitions for interventional MRI. Methods Distortions caused by gradient waveform inaccuracies were corrected using the gradient impulse response function (GIRF), which was measured by standard equipment and saved as a calibration file on the host computer. This file was used at runtime to calculate the predicted k-space trajectories for image reconstruction. Additionally, the off-resonance reconstruction frequency was modified in real-time to interactively de-blur spiral images. Results Real-time distortion correction for arbitrary image orientations was achieved in phantoms and healthy human volunteers. The GIRF predicted k-space trajectories matched measured k-space trajectories closely for spiral imaging. Spiral and EPI image distortion was visibly improved using the GIRF predicted trajectories. The GIRF calibration file showed no systematic drift in 4 months and was demonstrated to correct distortions after 30 minutes of continuous scanning despite gradient heating. Interactive off-resonance reconstruction was used to sharpen anatomical boundaries during continuous imaging. Conclusions This real-time distortion correction framework will enable the use of these high frame-rate imaging methods for MRI-guided interventions. PMID:26114951

  15. Effects of Video Games as Reinforcers for Computerized Addition Performance.

    ERIC Educational Resources Information Center

    Axelrod, Saul; And Others

    1987-01-01

    Four 2nd-grade students completed addition problems on a computer, using video games as reinforcers. Two variable ratio schedules of reinforcement failed to increase student accuracy or the rate of correct responses. In a no-games reinforcement condition, students had more opportunities to respond and had a greater number of correct answers.…

  16. Construct validation of an interactive digital algorithm for ostomy care.

    PubMed

    Beitz, Janice M; Gerlach, Mary A; Schafer, Vickie

    2014-01-01

    The purpose of this study was to evaluate construct validity for a previously face and content validated Ostomy Algorithm using digital real-life clinical scenarios. A cross-sectional, mixed-methods Web-based survey design study was conducted. Two hundred ninety-seven English-speaking RNs completed the study; participants practiced in both acute care and postacute settings, with 1 expert ostomy nurse (WOC nurse) and 2 nonexpert nurses. Following written consent, respondents answered demographic questions and completed a brief algorithm tutorial. Participants were then presented with 7 ostomy-related digital scenarios consisting of real-life photos and pertinent clinical information. Respondents used the 11 assessment components of the digital algorithm to choose management options. Participant written comments about the scenarios and the research process were collected. The mean overall percentage of correct responses was 84.23%. Mean percentage of correct responses for respondents with a self-reported basic ostomy knowledge was 87.7%; for those with a self-reported intermediate ostomy knowledge was 85.88% and those who were self-reported experts in ostomy care achieved 82.77% correct response rate. Five respondents reported having no prior ostomy care knowledge at screening and achieved an overall 45.71% correct response rate. No negative comments regarding the algorithm were recorded by participants. The new standardized Ostomy Algorithm remains the only face, content, and construct validated digital clinical decision instrument currently available. Further research on application at the bedside while tracking patient outcomes is warranted.

  17. Physician knowledge of and attitudes toward the Patient Protection and Affordable Care Act.

    PubMed

    Rocke, Daniel J; Thomas, Steven; Puscas, Liana; Lee, Walter T

    2014-02-01

    To assess otolaryngology physician knowledge of and attitudes toward the Patient Protection and Affordable Care Act (PPACA) and compare the association of bias toward the PPACA with knowledge of the provisions of the PPACA. Cross-sectional survey. Nationwide assessment. Members of the American Academy of Otolaryngology-Head and Neck Surgery. Otolaryngology physicians answered 10 true/false questions about major provisions of the PPACA. They also indicated their level of agreement with 9 statements about health care and the PPACA. Basic demographic information was collected. Email solicitation was sent to 9972 otolaryngologists and 647 responses were obtained (6.5% response rate). Overall correct response rate was 74%. Fewer than 60% of physicians correctly answered questions on whether small businesses receive tax credits for providing health insurance, the effect of the PPACA on Medicare benefits, and whether a government-run health insurance plan was created. Academic center practice setting, bias toward the PPACA, and Democratic Party affiliation were associated with significantly more correct responses. Overall physician knowledge of the PPACA is assessed as fair, although better than the general public in 2010. There are several areas where knowledge of physicians regarding the PPACA is poor, and this knowledge deficit is more pronounced within certain subgroups. These knowledge issues should be addressed by individual physicians and medical societies.

  18. Effects of bilateral eye movements on the retrieval of item, associative, and contextual information.

    PubMed

    Parker, Andrew; Relph, Sarah; Dagnall, Neil

    2008-01-01

    Two experiments are reported that investigate the effects of saccadic bilateral eye movements on the retrieval of item, associative, and contextual information. Experiment 1 compared the effects of bilateral versus vertical versus no eye movements on tests of item recognition, followed by remember-know responses and associative recognition. Supporting previous research, bilateral eye movements enhanced item recognition by increasing the hit rate and decreasing the false alarm rate. Analysis of remember-know responses indicated that eye movement effects were accompanied by increases in remember responses. The test of associative recognition found that bilateral eye movements increased correct responses to intact pairs and decreased false alarms to rearranged pairs. Experiment 2 assessed the effects of eye movements on the recall of intrinsic (color) and extrinsic (spatial location) context. Bilateral eye movements increased correct recall for both types of context. The results are discussed within the framework of dual-process models of memory and the possible neural underpinnings of these effects are considered.

  19. The Spectrum of Replication Errors in the Absence of Error Correction Assayed Across the Whole Genome of Escherichia coli.

    PubMed

    Niccum, Brittany A; Lee, Heewook; MohammedIsmail, Wazim; Tang, Haixu; Foster, Patricia L

    2018-06-15

    When the DNA polymerase that replicates the Escherichia coli chromosome, DNA Pol III, makes an error, there are two primary defenses against mutation: proofreading by the epsilon subunit of the holoenzyme and mismatch repair. In proofreading deficient strains, mismatch repair is partially saturated and the cell's response to DNA damage, the SOS response, may be partially induced. To investigate the nature of replication errors, we used mutation accumulation experiments and whole genome sequencing to determine mutation rates and mutational spectra across the entire chromosome of strains deficient in proofreading, mismatch repair, and the SOS response. We report that a proofreading-deficient strain has a mutation rate 4,000-fold greater than wild-type strains. While the SOS response may be induced in these cells, it does not contribute to the mutational load. Inactivating mismatch repair in a proofreading-deficient strain increases the mutation rate another 1.5-fold. DNA polymerase has a bias for converting G:C to A:T base pairs, but proofreading reduces the impact of these mutations, helping to maintain the genomic G:C content. These findings give an unprecedented view of how polymerase and error-correction pathways work together to maintain E. coli' s low mutation rate of 1 per thousand generations. Copyright © 2018, Genetics.

  20. The Success Rate of Neurology Residents in EEG Interpretation After Formal Training.

    PubMed

    Dericioglu, Nese; Ozdemir, Pınar

    2018-03-01

    EEG is an important tool for neurologists in both diagnosis and classification of seizures. It is not uncommon in clinical practice to see patients who were erroneously diagnosed as epileptic. Most of the time incorrect interpretation of EEG contributes significantly to this problem. In this study, we aimed to investigate the success rate of neurology residents in EEG interpretation after formal training. Eleven neurology residents were included in the study. Duration of EEG training (3 vs 4 months) and time since completion of EEG education were determined. Residents were randomly presented 30 different slides of representative EEG screenshots. They received 1 point for each correct response. The effect of training duration and time since training were investigated statistically. Besides, we looked at the success rate of each question to see whether certain patterns were more readily recognized than others. EEG training duration ( P = .93) and time since completion of training ( P = .16) did not influence the results. The success rate of residents for correct responses was between 17% and 50%. On the other hand, the success rate for each question varied between 0% and 91%. Overall, benign variants and focal ictal onset patterns were the most difficult to recognize. On 13 occasions (6.5%) nonepileptiform patterns were thought to represent epileptiform abnormalities. After formal training, neurology residents could identify ≤50% of the EEG patterns correctly. The wide variation in success rate among residents and also between questions implies that both personal characteristics and inherent EEG features influence successful EEG interpretation.

  1. Telephone survey of hospital staff knowledge of medical device surveillance in a Paris hospital.

    PubMed

    Mazeau, Valérie; Grenier-Sennelier, Catherine; Paturel, Denys Xavier; Mokhtari, Mostafa; Vidal-Trecan, Gwenaëlle

    2004-12-01

    Reporting of incidents or near incidents because of medical devices in French hospitals relies on procedures following European and national guidelines. The authors intend to evaluate hospital staff knowledge on these surveillance procedures as a marker of appropriate application. A telephone survey is conducted on a sample of Paris University hospital staff (n = 327) using a structured questionnaire. Two-hundred sixteen persons completed the questionnaire. The response rate was lower among physicians, especially surgeons paid on an hourly basis. Rates of correct answers were different according to age, seniority, job, and department categories. Physicians and nurses correctly answered questions on theoretical knowledge more often than the other job categories. However, on questions dealing with actual practice conditions, correct answers depended more on age and seniority with a U-shaped distribution (minimum rates in intermediate categories of age and seniority).

  2. Strongly screening corrections to antineutrino energy loss by β --decay of nuclides 53Fe, 54Fe, 55Fe, and 56Fe in supernova

    NASA Astrophysics Data System (ADS)

    Liu, Jing-Jing; Liu, Dong-Mei

    2018-06-01

    Based on the p-f shell-model, we discuss and calculate β--decay half-lives of neutron-rich nuclei, with a consideration of shell and pair effects, the decay energy, and the nucleon numbers. According to the linear response theory model, we study the effect of electron screening on the electron energy, beta-decay threshold energy, and the antineutrino energy loss rate by β--decay of some iron isotopes. We find that the electron screening antineutrino energy loss rates increase by about two orders of magnitude due to the shell effects and the pairing effect. Beta-decay rates with Q-value corrections due to strong electron screening are higher than those without the Q-value corrections by more than two orders of magnitude. Our conclusions may be helpful for the research on numerical simulations of the cooling of stars.

  3. Incorporating the gas analyzer response time in gas exchange computations.

    PubMed

    Mitchell, R R

    1979-11-01

    A simple method for including the gas analyzer response time in the breath-by-breath computation of gas exchange rates is described. The method uses a difference equation form of a model for the gas analyzer in the computation of oxygen uptake and carbon dioxide production and avoids a numerical differentiation required to correct the gas fraction wave forms. The effect of not accounting for analyzer response time is shown to be a 20% underestimation in gas exchange rate. The present method accurately measures gas exchange rate, is relatively insensitive to measurement errors in the analyzer time constant, and does not significantly increase the computation time.

  4. Hypercorrection of high confidence errors in lexical representations.

    PubMed

    Iwaki, Nobuyoshi; Matsushima, Hiroko; Kodaira, Kazumasa

    2013-08-01

    Memory errors associated with higher confidence are more likely to be corrected than errors made with lower confidence, a phenomenon called the hypercorrection effect. This study investigated whether the hypercorrection effect occurs with phonological information of lexical representations. In Experiment 1, 15 participants performed a Japanese Kanji word-reading task, in which the words had several possible pronunciations. In the initial task, participants were required to read aloud each word and indicate their confidence in their response; this was followed by receipt of visual feedback of the correct response. A hypercorrection effect was observed, indicating generality of this effect beyond previous observations in memories based upon semantic or episodic representations. This effect was replicated in Experiment 2, in which 40 participants performed the same task as in Experiment 1. When the participant's ratings of the practical value of the words were controlled, a partial correlation between confidence and likelihood of later correcting the initial mistaken response was reduced. This suggests that the hypercorrection effect may be partially caused by an individual's recognition of the practical value of reading the words correctly.

  5. Oxygen uptake on-kinetics during six-minute walk test predicts short-term outcomes after off-pump coronary artery bypass surgery.

    PubMed

    Rocco, Isadora Salvador; Viceconte, Marcela; Pauletti, Hayanne Osiro; Matos-Garcia, Bruna Caroline; Marcondi, Natasha Oliveira; Bublitz, Caroline; Bolzan, Douglas William; Moreira, Rita Simone Lopes; Reis, Michel Silva; Hossne, Nelson Américo; Gomes, Walter José; Arena, Ross; Guizilini, Solange

    2017-12-26

    We aimed to investigate the ability of oxygen uptake kinetics to predict short-term outcomes after off-pump coronary artery bypass grafting. Fifty-two patients aged 60.9 ± 7.8 years waiting for off-pump coronary artery bypass surgery were evaluated. The 6-min walk test distance was performed pre-operatively, while simultaneously using a portable cardiopulmonary testing device. The transition of oxygen uptake kinetics from rest to exercise was recorded to calculate oxygen uptake kinetics fitting a monoexponential regression model. Oxygen uptake at steady state, constant time, and mean response time corrected by work rate were analysed. Short-term clinical outcomes were evaluated during the early post-operative of off-pump coronary artery bypass surgery. Multivariate analysis showed body mass index, surgery time, and mean response time corrected by work rate as independent predictors for short-term outcomes. The optimal mean response time corrected by work rate cut-off to estimate short-term clinical outcomes was 1.51 × 10 -3  min 2 /ml. Patients with slower mean response time corrected by work rate demonstrated higher rates of hypertension, diabetes, EuroSCOREII, left ventricular dysfunction, and impaired 6-min walk test parameters. The per cent-predicted distance threshold of 66% in the pre-operative was associated with delayed oxygen uptake kinetics. Pre-operative oxygen uptake kinetics during 6-min walk test predicts short-term clinical outcomes after off-pump coronary artery bypass surgery. From a clinically applicable perspective, a threshold of 66% of pre-operative predicted 6-min walk test distance indicated slower kinetics, which leads to longer intensive care unit and post-surgery hospital length of stay. Implications for rehabilitation Coronary artery bypass grafting is a treatment aimed to improve expectancy of life and prevent disability due to the disease progression; The use of pre-operative submaximal functional capacity test enabled the identification of patients with high risk of complications, where patients with delayed oxygen uptake kinetics exhibited worse short-term outcomes; Our findings suggest the importance of the rehabilitation in the pre-operative in order to "pre-habilitate" the patients to the surgical procedure; Faster oxygen uptake on-kinetics could be achieved by improving the oxidative capacity of muscles and cardiovascular conditioning through rehabilitation, adding better results following cardiac surgery.

  6. Staircase-scene-based nonuniformity correction in aerial point target detection systems.

    PubMed

    Huo, Lijun; Zhou, Dabiao; Wang, Dejiang; Liu, Rang; He, Bin

    2016-09-01

    Focal-plane arrays (FPAs) are often interfered by heavy fixed-pattern noise, which severely degrades the detection rate and increases the false alarms in airborne point target detection systems. Thus, high-precision nonuniformity correction is an essential preprocessing step. In this paper, a new nonuniformity correction method is proposed based on a staircase scene. This correction method can compensate for the nonlinear response of the detector and calibrate the entire optical system with computational efficiency and implementation simplicity. Then, a proof-of-concept point target detection system is established with a long-wave Sofradir FPA. Finally, the local standard deviation of the corrected image and the signal-to-clutter ratio of the Airy disk of a Boeing B738 are measured to evaluate the performance of the proposed nonuniformity correction method. Our experimental results demonstrate that the proposed correction method achieves high-quality corrections.

  7. Creating trauma-informed correctional care: a balance of goals and environment

    PubMed Central

    Miller, Niki A.; Najavits, Lisa M.

    2012-01-01

    Background Rates of posttraumatic stress disorder and exposure to violence among incarcerated males and females in the US are exponentially higher than rates among the general population; yet, abrupt detoxification from substances, the pervasive authoritative presence and sensory and environmental trauma triggers can pose a threat to individual and institutional stability during incarceration. Objective The authors explore the unique challenges and promises of trauma-informed correctional care and suggest strategies for administrative support, staff development, programming, and relevant clinical approaches. Method A review of literature includes a comparison of gendered responses, implications for men's facilities, and the compatibility of trauma recovery goals and forensic programming goals. Results Trauma-informed care demonstrates promise in increasing offender responsivity to evidence-based cognitive behavioral programming that reduces criminal risk factors and in supporting integrated programming for offenders with substance abuse and co-occurring disorders. Conclusions Incorporating trauma recovery principles into correctional environments requires an understanding of criminal justice priorities, workforce development, and specific approaches to screening, assessment, and programming that unify the goals of clinical and security staff. PMID:22893828

  8. Client-centred development of an infrared thermal access switch for a young adult with severe spastic quadriplegic cerebral palsy.

    PubMed

    Memarian, Negar; Venetsanopoulos, Anastasios N; Chau, Tom

    2011-01-01

    This study reports a client-centred development of a non-contact access switch based on an infrared thermal imaging of mouth opening-closing activity of an individual with severe spastic quadriplegic cerebral palsy. Over a 6-month period, the client participated in five test sessions to inform the development of an infrared thermal switch. The client completed eight stimulus-response trials (switch test) and eight word-matching trials (scan test) using the infrared thermal switch and provided subjective feedback throughout. For the switch test, the client achieved an average correct activation rate of 90% and average response time of 2.4 s. His mean correct activation rate on the scan test improved from 65 to 80% over the course of system development, with an average response time of 11.7 s. An infrared thermography switch tuned to a client's extant orofacial gestures is a practical non-invasive access solution and warrants further research in clients with severe physical disability.

  9. [The effect of esmolol on corrected-QT interval, corrected-QT interval dispersion changes seen during anesthesia induction in hypertensive patients taking an angiotensin-converting enzyme inhibitor].

    PubMed

    Ceker, Zahit; Takmaz, Suna Akın; Baltaci, Bülent; Başar, Hülya

    2015-01-01

    The importance of minimizing the exaggerated sympatho-adrenergic responses and QT interval and QT interval dispersion changes that may develop due to laryngoscopy and tracheal intubation during anesthesia induction in the hypertensive patients is clear. Esmolol decreases the hemodynamic response to laryngoscopy and intubation. However, the effect of esmolol in decreasing the prolonged QT interval and QT interval dispersion as induced by laryngoscopy and intubation is controversial. We investigated the effect of esmolol on the hemodynamic, and corrected-QT interval and corrected-QT interval dispersion changes seen during anesthesia induction in hypertensive patients using angiotensin converting enzyme inhibitors. 60 ASA I-II patients, with essential hypertension using angiotensin converting enzyme inhibitors were included in the study. The esmolol group received esmolol at a bolus dose of 500mcg/kg followed by a 100mcg/kg/min infusion which continued until the 4th min after intubation. The control group received 0.9% saline similar to the esmolol group. The mean blood pressure, heart rate values and the electrocardiogram records were obtained as baseline values before the anesthesia, 5min after esmolol and saline administration, 3min after the induction and 30s, 2min and 4min after intubation. The corrected-QT interval was shorter in the esmolol group (p=0.012), the corrected-QT interval dispersion interval was longer in the control group (p=0.034) and the mean heart rate was higher in the control group (p=0.022) 30s after intubation. The risk of arrhythmia frequency was higher in the control group in the 4-min period following intubation (p=0.038). Endotracheal intubation was found to prolong corrected-QT interval and corrected-QT interval dispersion, and increase the heart rate during anesthesia induction with propofol in hypertensive patients using angiotensin converting enzyme inhibitors. These effects were prevented with esmolol (500mcg/kg bolus, followed by 100mcg/kg/min infusion). During induction, the blood pressure tends to decrease with esmolol where care is needed. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  10. Evaluating community pharmacists' HIV testing knowledge: A cross-sectional survey.

    PubMed

    Pineda, Larry J; Mercier, Renee-Claude; Dilworth, Thomas; Iandiorio, Michelle; Rankin, Shannon; Jakeman, Bernadette

    2015-01-01

    To assess community pharmacists' knowledge of human immunodeficiency virus (HIV), antiretroviral therapy, and new in-home oral fluid HIV test. A cross-sectional questionnaire administered to pharmacists, student pharmacists, and technicians before an education program at the New Mexico Pharmacists Association 2013 Mid-Winter Meeting in Albuquerque, NM. The main outcome measure was community pharmacists' correct response rate of 75% or more. Overall survey response rate of attendees was 89% (173/194 attendees). Among them 87 participants were community pharmacists; 87% of community pharmacists responded correctly when asked how HIV antiretroviral medications work and 84.3% correctly identified known sources of HIV infection. The 75% predefined adequate knowledge threshold was not met on any HIV screening or in-home HIV test knowledge items. Only 65.1% of community pharmacists correctly identified the minimum number of antiretroviral drugs that should be included in an ideal HIV treatment regimen. The only variable that positively influenced pharmacists' knowledge was age. An inverse relationship between pharmacist age and HIV knowledge was observed among study participants. Community pharmacists from urban and rural areas in New Mexico possessed adequate basic HIV knowledge, but did not demonstrate adequate HIV screening or in-home HIV test knowledge. Future educational interventions aimed at improving pharmacist knowledge in this area are warranted.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lessard, Francois; Archambault, Louis; Plamondon, Mathieu

    Purpose: Photon dosimetry in the kilovolt (kV) energy range represents a major challenge for diagnostic and interventional radiology and superficial therapy. Plastic scintillation detectors (PSDs) are potentially good candidates for this task. This study proposes a simple way to obtain accurate correction factors to compensate for the response of PSDs to photon energies between 80 and 150 kVp. The performance of PSDs is also investigated to determine their potential usefulness in the diagnostic energy range. Methods: A 1-mm-diameter, 10-mm-long PSD was irradiated by a Therapax SXT 150 unit using five different beam qualities made of tube potentials ranging from 80more » to 150 kVp and filtration thickness ranging from 0.8 to 0.2 mmAl + 1.0 mmCu. The light emitted by the detector was collected using an 8-m-long optical fiber and a polychromatic photodiode, which converted the scintillation photons to an electrical current. The PSD response was compared with the reference free air dose rate measured with a calibrated Farmer NE2571 ionization chamber. PSD measurements were corrected using spectra-weighted corrections, accounting for mass energy-absorption coefficient differences between the sensitive volumes of the ionization chamber and the PSD, as suggested by large cavity theory (LCT). Beam spectra were obtained from x-ray simulation software and validated experimentally using a CdTe spectrometer. Correction factors were also obtained using Monte Carlo (MC) simulations. Percent depth dose (PDD) measurements were compensated for beam hardening using the LCT correction method. These PDD measurements were compared with uncorrected PSD data, PDD measurements obtained using Gafchromic films, Monte Carlo simulations, and previous data. Results: For each beam quality used, the authors observed an increase of the energy response with effective energy when no correction was applied to the PSD response. Using the LCT correction, the PSD response was almost energy independent, with a residual 2.1% coefficient of variation (COV) over the 80-150-kVp energy range. Monte Carlo corrections reduced the COV to 1.4% over this energy range. All PDD measurements were in good agreement with one another except for the uncorrected PSD data, in which an over-response was observed with depth (13% at 10 cm with a 100 kVp beam), showing that beam hardening had a non-negligible effect on the PSD response. A correction based on LCT compensated very well for this effect, reducing the over-response to 3%.Conclusion: In the diagnostic energy range, PSDs show high-energy dependence, which can be corrected using spectra-weighted mass energy-absorption coefficients, showing no considerable sign of quenching between these energies. Correction factors obtained by Monte Carlo simulations confirm that the approximations made by LCT corrections are valid. Thus, PSDs could be useful for real-time dosimetry in radiology applications.« less

  12. How Question Types Reveal Student Thinking: An Experimental Comparison of Multiple-True-False and Free-Response Formats

    PubMed Central

    Hubbard, Joanna K.; Potts, Macy A.; Couch, Brian A.

    2017-01-01

    Assessments represent an important component of undergraduate courses because they affect how students interact with course content and gauge student achievement of course objectives. To make decisions on assessment design, instructors must understand the affordances and limitations of available question formats. Here, we use a crossover experimental design to identify differences in how multiple-true-false (MTF) and free-response (FR) exam questions reveal student thinking regarding specific conceptions. We report that correct response rates correlate across the two formats but that a higher percentage of students provide correct responses for MTF questions. We find that MTF questions reveal a high prevalence of students with mixed (correct and incorrect) conceptions, while FR questions reveal a high prevalence of students with partial (correct and unclear) conceptions. These results suggest that MTF question prompts can direct students to address specific conceptions but obscure nuances in student thinking and may overestimate the frequency of particular conceptions. Conversely, FR questions provide a more authentic portrait of student thinking but may face limitations in their ability to diagnose specific, particularly incorrect, conceptions. We further discuss an intrinsic tension between question structure and diagnostic capacity and how instructors might use multiple formats or hybrid formats to overcome these obstacles. PMID:28450446

  13. Identifying and Predicting Classes of Response to Explicit Phonological Spelling Instruction during Independent Composing

    ERIC Educational Resources Information Center

    Amtmann, Dagmar; Abbott, Robert D.; Berninger, Virginia W.

    2008-01-01

    After explicit spelling instruction, low achieving second grade spellers increased the number of correctly spelled words during composing but differed in response trajectories. Class 1 (low initial and slow growth) had the lowest initial performance and improved at a relatively slow rate. Class 2 (high initial and fast growth) started higher than…

  14. It Matters Whether Reading Comprehension Is Conceptualised as Rate or Accuracy

    ERIC Educational Resources Information Center

    Rønberg, Louise Flensted; Petersen, Dorthe Klint

    2016-01-01

    This study shows that it makes a difference whether accuracy measures or rate measures are used when assessing reading comprehension. When the outcome is reading comprehension accuracy (i.e., the number of correct responses), word reading skills (measured as access to orthographic representations) account for a modest amount of the variance in the…

  15. Joint release rate estimation and measurement-by-measurement model correction for atmospheric radionuclide emission in nuclear accidents: An application to wind tunnel experiments.

    PubMed

    Li, Xinpeng; Li, Hong; Liu, Yun; Xiong, Wei; Fang, Sheng

    2018-03-05

    The release rate of atmospheric radionuclide emissions is a critical factor in the emergency response to nuclear accidents. However, there are unavoidable biases in radionuclide transport models, leading to inaccurate estimates. In this study, a method that simultaneously corrects these biases and estimates the release rate is developed. Our approach provides a more complete measurement-by-measurement correction of the biases with a coefficient matrix that considers both deterministic and stochastic deviations. This matrix and the release rate are jointly solved by the alternating minimization algorithm. The proposed method is generic because it does not rely on specific features of transport models or scenarios. It is validated against wind tunnel experiments that simulate accidental releases in a heterogonous and densely built nuclear power plant site. The sensitivities to the position, number, and quality of measurements and extendibility of the method are also investigated. The results demonstrate that this method effectively corrects the model biases, and therefore outperforms Tikhonov's method in both release rate estimation and model prediction. The proposed approach is robust to uncertainties and extendible with various center estimators, thus providing a flexible framework for robust source inversion in real accidents, even if large uncertainties exist in multiple factors. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Transcatheter arterial chemoembolization for advanced hepatocellular carcinoma with inferior vena cava and right atrial tumors.

    PubMed

    Chern, M C; Chuang, V P; Cheng, T; Lin, Z H; Lin, Y M

    2008-01-01

    Advanced hepatocelluar carcinoma (HCC) with invasion of venous systems usually indicates not only a poor prognosis but also a contraindication for transcatheter arterial chemoembolization (TACE). This study evaluated the feasibility of TACE for advanced HCC with inferior vena cava (IVC) and right atrium (RA) tumors and, also, to search for the ideal embolization particle size. Twenty-six patients who had HCC invasion into the IVC included five patients with coexistent RA tumors that were treated with TACE. The chemoembolization method was cisplatin, doxorubicin, and mitomycin C mixed with Lipiodol and Ivalon. The selection of Ivalon particles was divided into two groups based on their size: (A) >180 microm, N = 9; and (B) 47-180 microm, N = 17. The overall response rate was 53.8% (14/26). Based on the response to TACE, the median survival period of the entire group was 4.2 months (range, 1.5 to 76.7 months). The median survival period of the 14 responders was 13.5 months (1.5-76.7 months), and that of the 12 nonresponders, 3.3 months (2.1 to 24.3 months) (p < 0.002). Comparing the two Ivalon particle sizes, the response rate was 12.5% (1/8 [corrected] patients) for group A and 72.2% [corrected] for group B (13/18 [corrected] patients) (p < 0.01). [corrected] No serious complication was observed post-chemoembolization. In conclusion, TACE is a safe and effective treatment for advanced HCC with IVC and RA tumors, and small Ivalon particles (47-180 microm) are superior to large ones (>180 microm).

  17. Using polynomials to simplify fixed pattern noise and photometric correction of logarithmic CMOS image sensors.

    PubMed

    Li, Jing; Mahmoodi, Alireza; Joseph, Dileepan

    2015-10-16

    An important class of complementary metal-oxide-semiconductor (CMOS) image sensors are those where pixel responses are monotonic nonlinear functions of light stimuli. This class includes various logarithmic architectures, which are easily capable of wide dynamic range imaging, at video rates, but which are vulnerable to image quality issues. To minimize fixed pattern noise (FPN) and maximize photometric accuracy, pixel responses must be calibrated and corrected due to mismatch and process variation during fabrication. Unlike literature approaches, which employ circuit-based models of varying complexity, this paper introduces a novel approach based on low-degree polynomials. Although each pixel may have a highly nonlinear response, an approximately-linear FPN calibration is possible by exploiting the monotonic nature of imaging. Moreover, FPN correction requires only arithmetic, and an optimal fixed-point implementation is readily derived, subject to a user-specified number of bits per pixel. Using a monotonic spline, involving cubic polynomials, photometric calibration is also possible without a circuit-based model, and fixed-point photometric correction requires only a look-up table. The approach is experimentally validated with a logarithmic CMOS image sensor and is compared to a leading approach from the literature. The novel approach proves effective and efficient.

  18. Associative Flow Rule Used to Include Hydrostatic Stress Effects in Analysis of Strain-Rate-Dependent Deformation of Polymer Matrix Composites

    NASA Technical Reports Server (NTRS)

    Goldberg, Robert K.; Roberts, Gary D.

    2004-01-01

    designing reliable composite engine cases that are lighter than the metal cases in current use. The types of polymer matrix composites that are likely to be used in such an application have a deformation response that is nonlinear and that varies with strain rate. The nonlinearity and the strain-rate dependence of the composite response are due primarily to the matrix constituent. Therefore, in developing material models to be used in the design of impact-resistant composite engine cases, the deformation of the polymer matrix must be correctly analyzed. However, unlike in metals, the nonlinear response of polymers depends on the hydrostatic stresses, which must be accounted for within an analytical model. By applying micromechanics techniques along with given fiber properties, one can also determine the effects of the hydrostatic stresses in the polymer on the overall composite deformation response. First efforts to account for the hydrostatic stress effects in the composite deformation applied purely empirical methods that relied on composite-level data. In later efforts, to allow polymer properties to be characterized solely on the basis of polymer data, researchers at the NASA Glenn Research Center developed equations to model the polymers that were based on a non-associative flow rule, and efforts to use these equations to simulate the deformation of representative polymer materials were reasonably successful. However, these equations were found to have difficulty in correctly analyzing the multiaxial stress states found in the polymer matrix constituent of a composite material. To correct these difficulties, and to allow for the accurate simulation of the nonlinear strain-rate-dependent deformation analysis of polymer matrix composites, in the efforts reported here Glenn researchers reformulated the polymer constitutive equations from basic principles using the concept of an associative flow rule. These revised equations were characterized and validated in an experimental program carried out through a university grant with the Ohio State University, wherein tensile and shear deformation data were obtained for a representative polymer for strain rates ranging from quasi-static to high rates of several hundred per second. Tensile deformation data also were obtained over a variety of strain rates and fiber orientation angles for a representative polymer matrix composite composed using the polymer.

  19. A Novel Low-Power, High-Performance, Zero-Maintenance Closed-Path Trace Gas Eddy Covariance System with No Water Vapor Dilution or Spectroscopic Corrections

    NASA Astrophysics Data System (ADS)

    Sargent, S.; Somers, J. M.

    2015-12-01

    Trace-gas eddy covariance flux measurement can be made with open-path or closed-path analyzers. Traditional closed-path trace-gas analyzers use multipass absorption cells that behave as mixing volumes, requiring high sample flow rates to achieve useful frequency response. The high sample flow rate and the need to keep the multipass cell extremely clean dictates the use of a fine-pore filter that may clog quickly. A large-capacity filter cannot be used because it would degrade the EC system frequency response. The high flow rate also requires a powerful vacuum pump, which will typically consume on the order of 1000 W. The analyzer must measure water vapor for spectroscopic and dilution corrections. Open-path analyzers are available for methane, but not for nitrous oxide. The currently available methane analyzers have low power consumption, but are very large. Their large size degrades frequency response and disturbs the air flow near the sonic anemometer. They require significant maintenance to keep the exposed multipass optical surfaces clean. Water vapor measurements for dilution and spectroscopic corrections require a separate water vapor analyzer. A new closed-path eddy covariance system for measuring nitrous oxide or methane fluxes provides an elegant solution. The analyzer (TGA200A, Campbell Scientific, Inc.) uses a thermoelectrically-cooled interband cascade laser. Its small sample-cell volume and unique sample-cell configuration (200 ml, 1.5 m single pass) provide excellent frequency response with a low-power scroll pump (240 W). A new single-tube Nafion® dryer removes most of the water vapor, and attenuates fluctuations in the residual water vapor. Finally, a vortex intake assembly eliminates the need for an intake filter without adding volume that would degrade system frequency response. Laboratory testing shows the system attenuates the water vapor dilution term by more than 99% and achieves a half-power band width of 3.5 Hz.

  20. Intertrial-interval effects on sensitivity (A') and response bias (B") in a temporal discrimination by rats.

    PubMed Central

    Raslear, T G; Shurtleff, D; Simmons, L

    1992-01-01

    Killeen and Fetterman's (1988) behavioral theory of animal timing predicts that decreases in the rate of reinforcement should produce decreases in the sensitivity (A') of temporal discriminations and a decrease in miss and correct rejection rates (decrease in bias toward "long" responses). Eight rats were trained on a 10- versus 0.1-s temporal discrimination with an intertrial interval of 5 s and were subsequently tested on probe days on the same discrimination with intertrial intervals of 1, 2.5, 5, 10, or 20 s. The rate of reinforcement declined for all animals as intertrial interval increased. Although sensitivity (A') decreased with increasing intertrial interval, all rats showed an increase in bias to make long responses. PMID:1447544

  1. Dental Faculty Accuracy When Using Diagnostic Codes: A Pilot Study.

    PubMed

    Sutton, Jeanne C; Fay, Rose-Marie; Huynh, Carolyn P; Johnson, Cleverick D; Zhu, Liang; Quock, Ryan L

    2017-05-01

    The aim of this study was to examine the accuracy of dental faculty members' utilization of diagnostic codes and resulting treatment planning based on radiographic interproximal tooth radiolucencies. In 2015, 50 full-time and part-time general dentistry faculty members at one U.S. dental school were shown a sequence of 15 bitewing radiographs; one interproximal radiolucency was highlighted on each bitewing. For each radiographic lesion, participants were asked to choose the most appropriate diagnostic code (from a concise list of five codes, corresponding to lesion progression to outer/inner halves of enamel and outer/middle/pulpal thirds of dentin), acute treatment (attempt to arrest/remineralize non-invasively, operative intervention, or no treatment), and level of confidence in choices. Diagnostic and treatment choices of participants were compared to "gold standard" correct responses, as determined by expert radiology and operative faculty members, respectively. The majority of the participants selected the correct diagnostic code for lesions in the outer one-third of dentin (p<0.0001) and the pulpal one-third of dentin (p<0.0001). For lesions in the outer and inner halves of enamel and the middle one-third of dentin, the correct rates were moderate. However, the majority of the participants chose correct treatments on all types of lesions (correct rate 63.6-100%). Faculty members' confidence in their responses was generally high for all lesions, all above 90%. Diagnostic codes were appropriately assigned by participants for the very deepest lesions, but they were not assigned accurately for more incipient lesions (limited to enamel). Paradoxically, treatment choices were generally correct, regardless of diagnostic choices. Further calibration is needed to improve faculty use and teaching of diagnostic codes.

  2. Experimental and Analytical Evaluation of Stressing-Rate State Evolution in Rate-State Friction Laws

    NASA Astrophysics Data System (ADS)

    Bhattacharya, P.; Rubin, A. M.; Bayart, E.; Savage, H. M.; Marone, C.; Beeler, N. M.

    2013-12-01

    Standard rate and state friction laws fail to explain the full range of observations from laboratory friction experiments. A new state evolution law has been proposed by Nagata et al. (2012) that adds a linear stressing-rate-dependent term to the Dieterich (aging) law, which may provide a remedy. They introduce a parameter c that controls the contribution of the stressing rate to state evolution. We show through analytical approximations that the new law can transition between the responses of the traditional Dieterich (aging) and Ruina (slip) laws in velocity step up/down experiments when the value of c is tuned properly. In particular, for c = 0 the response is pure aging while for finite, non-zero c one observes slip law like behavior for small velocity jumps but aging law like response for larger jumps. The magnitude of the velocity jump required to see this transition between aging and slip behaviour increases as c increases. In the limit of c >> 1 the response to velocity steps becomes purely slip law like. In this limit, numerical simulations show that this law loses its appealing time dependent healing property. An approach using Markov Chain Monte Carlo parameter search on data for large magnitude velocity step tests reveals that it is only possible to determine a lower bound on c using datasets that are well explained by the slip law. For a dataset with velocity steps of two orders of magnitude on simulated fault gouge we find this lower bound to be c ≈ 10.0. This is significantly larger than c ≈ 2.0 used by Nagata et al. (2012) to fit their data (mainly bare rock experiments with smaller excursions from steady state than our dataset). Similar parameter estimation exercises on slide hold slide data reveal that none of the state evolution laws considered - Dieterich, Ruina, Kato-Tullis and Nagata - match the relevant features of the data. In particular, even the aging law predicts only the correct rate of healing for long hold times but not the correct amount of healing. For c = 10.0, the Nagata law shows significant slip dependence in healing rate for long hold times which is at odds with the lab data and similar to the slip law response. If one accepts frictional healing observed in the laboratory as a ';proper' analog for fault strengthening over the interseismic period, we conclude that none of the investigated state evolution laws provides a comprehensive and correct constitutive relation.

  3. Spatial cues more salient than color cues in cotton-top tamarins (Saguinus oedipus) reversal learning.

    PubMed

    Gaudio, Jennifer L; Snowdon, Charles T

    2008-11-01

    Animals living in stable home ranges have many potential cues to locate food. Spatial and color cues are important for wild Callitrichids (marmosets and tamarins). Field studies have assigned the highest priority to distal spatial cues for determining the location of food resources with color cues serving as a secondary cue to assess relative ripeness, once a food source is located. We tested two hypotheses with captive cotton-top tamarins: (a) Tamarins will demonstrate higher rates of initial learning when rewarded for attending to spatial cues versus color cues. (b) Tamarins will show higher rates of correct responses when transferred from color cues to spatial cues than from spatial cues to color cues. The results supported both hypotheses. Tamarins rewarded based on spatial location made significantly more correct choices and fewer errors than tamarins rewarded based on color cues during initial learning. Furthermore, tamarins trained on color cues showed significantly increased correct responses and decreased errors when cues were reversed to reward spatial cues. Subsequent reversal to color cues induced a regression in performance. For tamarins spatial cues appear more salient than color cues in a foraging task. (PsycINFO Database Record (c) 2008 APA, all rights reserved).

  4. Developing of discrimination experiment to find most adequate model of plant’s multi-nutrient functional response

    NASA Astrophysics Data System (ADS)

    Saltykov, M. Yu; Bartsev, S. I.

    2017-02-01

    To create reliable Closed Ecological Life Support Systems (CELSS) it is necessary to have models which can predict CELSS dynamic with good accuracy. However it was shown that conventional ecological models cannot describe CELSS correctly if it is closed by more than one element. This problem can be solved by means more complex models than conventional ones - so called flexible metabolism models. However it is possible that CELSS also can be described correctly in “semi-conventional” framework - when only one trophic level is described by flexible metabolism model. Another problem in CELSS modeling is existence of different and incompatible hypotheses about relationships between plants growth rate and amounts of nutrients (functional responses). Difficulty of testing these hypotheses is associated with multi-nutrient dependency of growth rate and comprehensive experimental studies are expensive and time-consuming. This work is devoted to testing the hypothesis that “semi-conventional” approach is enough to describe CELSS, and to planning the discrimination experiment on selecting correct type of the plant’s functional response. To do that three different models of plants (one flexible and two conventional) were investigated both in the scope of CELSS model, and in hemostat model. Numerical simulations show that each of the models has typical patterns which can be determined in experiment with real plants.

  5. The general matching law describes choice on concurrent variable-interval schedules of wheel-running reinforcement.

    PubMed

    Belke, T W; Belliveau, J

    2001-05-01

    Six male Wistar rats were exposed to concurrent variable-interval schedules of wheel-running reinforcement. The reinforcer associated with each alternative was the opportunity to run for 15 s, and the duration of the changeover delay was 1 s. Results suggested that time allocation was more sensitive to relative reinforcement rate than was response allocation. For time allocation, the mean slopes and intercepts were 0.82 and 0.008, respectively. In contrast, for response allocation, mean slopes and intercepts were 0.60 and 0.03, respectively. Correction for low response rates and high rates of changing over, however, increased slopes for response allocation to about equal those for time allocation. The results of the present study suggest that the two-operant form of the matching law can be extended to wheel-running reinforcement. 'I'he effects of a low overall response rate, a short Changeover delay, and long postreinforcement pausing on the assessment of matching in the present study are discussed.

  6. Correcting a Metacognitive Error: Feedback Increases Retention of Low-Confidence Correct Responses

    ERIC Educational Resources Information Center

    Butler, Andrew C.; Karpicke, Jeffrey D.; Roediger, Henry L., III

    2008-01-01

    Previous studies investigating posttest feedback have generally conceptualized feedback as a method for correcting erroneous responses, giving virtually no consideration to how feedback might promote learning of correct responses. Here, the authors show that when correct responses are made with low confidence, feedback serves to correct this…

  7. Teaching Dental Students About Incarceration and Correctional Dentistry: Results from a National Survey.

    PubMed

    Candamo, Fiorella; Tobey, Matthew; Simon, Lisa

    2018-03-01

    People who are incarcerated or have a history of incarceration have high rates of dental disease, but access to dental treatment is often a challenge during and after incarceration. Dental students' exposure to this population is unknown: no data exist regarding the number of schools that provide didactic and clinical training in correctional dentistry. The aim of this study was to assess the extent of instruction in correctional dentistry and clinical opportunities at correctional facilities for dental students in the U.S. A survey was distributed to the academic deans at all 66 U.S. dental schools in 2017. Respondents were asked if their institutions had curricular content on correctional health and if they provided clinical opportunities in the correctional setting. Respondents from 30 schools completed the survey, for a response rate of 45%. Nearly two-thirds of the respondents said their institutions offered didactic instruction on the impact of incarceration on health, and eight schools offered a clinical experience at a correctional facility. The most common format was a community-based dental externship involving fourth-year dental students. Oral exams, prophylaxis, and extractions were the most common procedures performed. Respondents from schools that offered a clinical experience agreed more strongly than those that did not that exposure to correctional health care was important and that their students believed incarceration to be a social determinant of health. This study found that a substantial proportion of dental schools offered didactic education on correctional health, but a much smaller number offered student rotations in correctional facilities.

  8. Modeling rate sensitivity of exercise transient responses to limb motion.

    PubMed

    Yamashiro, Stanley M; Kato, Takahide

    2014-10-01

    Transient responses of ventilation (V̇e) to limb motion can exhibit predictive characteristics. In response to a change in limb motion, a rapid change in V̇e is commonly observed with characteristics different than during a change in workload. This rapid change has been attributed to a feed-forward or adaptive response. Rate sensitivity was explored as a specific hypothesis to explain predictive V̇e responses to limb motion. A simple model assuming an additive feed-forward summation of V̇e proportional to the rate of change of limb motion was studied. This model was able to successfully account for the adaptive phase correction observed during human sinusoidal changes in limb motion. Adaptation of rate sensitivity might also explain the reduction of the fast component of V̇e responses previously reported following sudden exercise termination. Adaptation of the fast component of V̇e response could occur by reduction of rate sensitivity. Rate sensitivity of limb motion was predicted by the model to reduce the phase delay between limb motion and V̇e response without changing the steady-state response to exercise load. In this way, V̇e can respond more quickly to an exercise change without interfering with overall feedback control. The asymmetry between responses to an incremental and decremental ramp change in exercise can also be accounted for by the proposed model. Rate sensitivity leads to predicted behavior, which resembles responses observed in exercise tied to expiratory reserve volume. Copyright © 2014 the American Physiological Society.

  9. Using Polynomials to Simplify Fixed Pattern Noise and Photometric Correction of Logarithmic CMOS Image Sensors

    PubMed Central

    Li, Jing; Mahmoodi, Alireza; Joseph, Dileepan

    2015-01-01

    An important class of complementary metal-oxide-semiconductor (CMOS) image sensors are those where pixel responses are monotonic nonlinear functions of light stimuli. This class includes various logarithmic architectures, which are easily capable of wide dynamic range imaging, at video rates, but which are vulnerable to image quality issues. To minimize fixed pattern noise (FPN) and maximize photometric accuracy, pixel responses must be calibrated and corrected due to mismatch and process variation during fabrication. Unlike literature approaches, which employ circuit-based models of varying complexity, this paper introduces a novel approach based on low-degree polynomials. Although each pixel may have a highly nonlinear response, an approximately-linear FPN calibration is possible by exploiting the monotonic nature of imaging. Moreover, FPN correction requires only arithmetic, and an optimal fixed-point implementation is readily derived, subject to a user-specified number of bits per pixel. Using a monotonic spline, involving cubic polynomials, photometric calibration is also possible without a circuit-based model, and fixed-point photometric correction requires only a look-up table. The approach is experimentally validated with a logarithmic CMOS image sensor and is compared to a leading approach from the literature. The novel approach proves effective and efficient. PMID:26501287

  10. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 2. How a mistake led BEIR I to adopt LNT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calabrese, Edward J., E-mail: edwardc@schoolph.uma

    This paper reveals that nearly 25 years after the used Russell's dose-rate data to support the adoption of the linear-no-threshold (LNT) dose response model for genetic and cancer risk assessment, Russell acknowledged a significant under-reporting of the mutation rate of the historical control group. This error, which was unknown to BEIR I, had profound implications, leading it to incorrectly adopt the LNT model, which was a decision that profoundly changed the course of risk assessment for radiation and chemicals to the present. -- Highlights: • The BEAR I Genetics Panel made an error in denying dose rate for mutation. •more » The BEIR I Genetics Subcommittee attempted to correct this dose rate error. • The control group used for risk assessment by BEIR I is now known to be in error. • Correcting this error contradicts the LNT, supporting a threshold model.« less

  11. SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoerner, M; Hintenlang, D

    Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60more » gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.« less

  12. Comparison of violence and abuse in juvenile correctional facilities and schools.

    PubMed

    Davidson-Arad, Bilha; Benbenishty, Rami; Golan, Miriam

    2009-02-01

    Peer violence, peer sexual harassment and abuse, and staff abuse experienced by boys and girls in juvenile correctional facilities are compared with those experienced by peers in schools in the community. Responses of 360 youths in 20 gender-separated correctional facilities in Israel to a questionnaire tapping these forms of mistreatment were compared with those of 7,012 students in a representative sample of Israeli junior high and high schools. Victimization was reported more frequently by those in correctional facilities than by those in schools. However, some of the more prevalent forms of violence and abuse were reported with equal frequency in both settings, and some more frequently in schools. Despite being victimized more frequently, those in the correctional facilities tended to view their victimization as a significantly less serious problem than those in the schools and to rate the staff as doing a better job of dealing with the problem.

  13. Beyond hypercorrection: remembering corrective feedback for low-confidence errors.

    PubMed

    Griffiths, Lauren; Higham, Philip A

    2018-02-01

    Correcting errors based on corrective feedback is essential to successful learning. Previous studies have found that corrections to high-confidence errors are better remembered than low-confidence errors (the hypercorrection effect). The aim of this study was to investigate whether corrections to low-confidence errors can also be successfully retained in some cases. Participants completed an initial multiple-choice test consisting of control, trick and easy general-knowledge questions, rated their confidence after answering each question, and then received immediate corrective feedback. After a short delay, they were given a cued-recall test consisting of the same questions. In two experiments, we found high-confidence errors to control questions were better corrected on the second test compared to low-confidence errors - the typical hypercorrection effect. However, low-confidence errors to trick questions were just as likely to be corrected as high-confidence errors. Most surprisingly, we found that memory for the feedback and original responses, not confidence or surprise, were significant predictors of error correction. We conclude that for some types of material, there is an effortful process of elaboration and problem solving prior to making low-confidence errors that facilitates memory of corrective feedback.

  14. Applying translabial ultrasound to detect synthetic slings-You can do it too! A comparison of urology trainees to an attending radiologist.

    PubMed

    Shen, Jim K; Faaborg, Daniel; Rouse, Glenn; Kelly, Isaac; Li, Roger; Alsyouf, Muhannad; Myklak, Kristene; Distelberg, Brian; Staack, Andrea

    2017-09-01

    Translabial ultrasound (TUS) is a useful tool for identifying and assessing synthetic slings. This study evaluates the ability of urology trainees to learn basic pelvic anatomy and sling assessment on TUS. Eight urology trainees (six residents and two medical students) received a lecture reviewing basic anatomy and sling assessment on TUS followed by review of two training cases. Next, they underwent a 126-question examination assessing their ability to identify anatomic planes and structures in those planes, identify the presence of slings, and assess the location and intactness of a sling. The correct response rate was compared to that of an attending radiologist experienced in reading TUS. Non-parametric tests (Fisher's exact, chi-squared tests, and Yates correction) were used for statistical analysis, with P < 0.05 considered significant. 847/1008 (84.0%) of questions were answered correctly by eight trainees compared to 119/126 (94.4%) by the radiologist (P = 0.001). The trainees' correct response rates and Fisher's exact test P values associated with the difference in correct answers between radiologist and trainee were as follows: identification of anatomic plane (94.4%; P = 0.599), identification of structure in sagittal view (80.6%; P = 0.201), identification of structure in transverse view (88.2%; P = 0.696), presence of synthetic sling (95.8%; P = 1.000), location of sling along the urethra in (71.5%; P = 0.403), intactness of sling (82.6%; P = 0.311), and laterality of sling disruption (75.0%; P = 0.076). Urology trainees can quickly learn to identify anatomic landmarks and assess slings on TUS with reasonable proficiency compared to an experienced attending radiologist. © 2017 Wiley Periodicals, Inc.

  15. Mathematical modelling of the maternal cardiovascular system in the three stages of pregnancy.

    PubMed

    Corsini, Chiara; Cervi, Elena; Migliavacca, Francesco; Schievano, Silvia; Hsia, Tain-Yen; Pennati, Giancarlo

    2017-09-01

    In this study, a mathematical model of the female circulation during pregnancy is presented in order to investigate the hemodynamic response to the cardiovascular changes associated with each trimester of pregnancy. First, a preliminary lumped parameter model of the circulation of a non-pregnant female was developed, including the heart, the systemic circulation with a specific block for the uterine district and the pulmonary circulation. The model was first tested at rest; then heart rate and vascular resistances were individually varied to verify the correct response to parameter alterations characterising pregnancy. In order to simulate hemodynamics during pregnancy at each trimester, the main changes applied to the model consisted in reducing vascular resistances, and simultaneously increasing heart rate and ventricular wall volumes. Overall, reasonable agreement was found between model outputs and in vivo data, with the trends of the cardiac hemodynamic quantities suggesting correct response of the heart model throughout pregnancy. Results were reported for uterine hemodynamics, with flow tracings resembling typical Doppler velocity waveforms at each stage, including pulsatility indexes. Such a model may be used to explore the changes that happen during pregnancy in female with cardiovascular diseases. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  16. Do older adults change their eyewitness reports when re-questioned?

    PubMed

    Henkel, Linda A

    2014-05-01

    This study examined how older adults responded to different types of pressure to change their responses when questioned a second time about their memory for a crime. After watching a video of a crime and answering questions about remembered details, younger (18-22 years) and older adults (64-91 years) were either given negative feedback about their memory performance, were told that most people their age did poorly on the memory test (stereotype threat), or were simply asked to answer the questions again. This was done regardless of their actual accuracy, and the questions were then repeated. Results showed that both younger and older adults changed significantly more responses following negative feedback and changed more responses on misleading than on nonleading questions. Among older adults, as age increased, accuracy decreased and rate of response change increased. People were moderately confident overall about both their correct and incorrect responses. These results highlight the dangers of repeatedly questioning older witnesses with misleading questions and suggest that the responses that are changed may come to be remembered confidently-regardless of whether they are correct or incorrect.

  17. [On-orbit response variation analysis of FY-3 MERSI reflective solar bands based on Dunhuang site calibration].

    PubMed

    Sun, Ling; Guo, Mao-Hua; Xu, Na; Zhang, Li-Jun; Liu, Jing-Jing; Hu, Xiu-Qing; Li, Yuan; Rong, Zhi-Guo; Zhao, Ze-Hui

    2012-07-01

    MERSI is the keystone payload of FengYun-3 and there have been two sensors operating on-orbit since 2008. The on-orbit response changes obviously at reflective solar bands (RSBs) and must be effectively monitored and corrected. However MERSI can not realize the RSBs onboard absolute radiometric calibration. This paper presents a new vicarious calibration (VC) method for RSBs based on in-situ BRDF model, and vector radiometric transfer model 6SV with gaseous absorption correction using MOTRAN. The results of synchronous VC experiments in 4 years show that the calibration uncertainties are within 5% except for band at the center of water vapor absorption, and 3% for most bands. Aqua MODIS was taken as the radiometric reference to evaluate the accuracy of this VC method. By comparison of the simulated radiation at top of atmosphere (TOA) with MODIS measurement, it was revealed that the average relative differences are within 3% for window bands with wavelengths less than 1 microm, and 5% for bands with wavelengths larger than 1 microm (except for band 7 at 2.1 microm). Besides, the synchronous nadir observation cross analysis shows the excellent agreement between re-calibrated MERSI TOA apparent reflectance and MODIS measurements. Based on the multi-year site calibration results, it was found that the calibration coefficients could be fitted with two-order polynomials, thus the daily calibration updates could be realized and the response variation between two calibration experiments could be corrected timely; there are large response changes at bands with wavelengths less than 0.6 microm, the degradation rate of the first year at band 8 (0.41 microm) is about 14%; the on-orbit response degradation is maximum at the beginning, the degradation rates slow down after one year in operation, and after two years the responses even increase at some band with wavelengths larger than 0.6 microm.

  18. Disciplinary responses to misconduct among female prison inmates with mental illness, substance use disorders, and co-occurring disorders.

    PubMed

    Houser, Kimberly; Belenko, Steven

    2015-03-01

    Most female inmates have mental health, substance use, or co-occurring disorders (CODs), which can create greater difficulty adjusting to incarceration and higher rates of prison misconduct. The response of prison officials to institutional misbehaviors has important implications for female inmates' experiences while incarcerated, their likelihood of parole, and the clinical course of their condition. This article examined whether disciplinary actions are more severe for women with CODs. Data were provided by the Pennsylvania Department of Corrections for all female state prison inmates incarcerated between January 1, 2007, and July 30, 2009 (N = 2,279). The final sample of 211 women included those who had committed a minor misconduct during their incarceration. Disorder categories were created based on intake assessments, and multivariate models were estimated to determine the effect of disorder category on whether the prison imposed a severe or minor disciplinary response to the misconduct. The odds of receiving severe disciplinary responses to minor misconduct was significantly greater for women with CODs than those with the singular disorders of mental illness or substance abuse disorders, or those with no disorders. Findings suggest correctional institutions are responding in a punitive manner to the symptomatic manifestations of CODs in female inmates. These findings suggest the importance of screening instruments in correctional settings that assess for the presence of dual disorders. In addition, correctional administrators must implement training protocols for correctional officers and staff on the complexity of CODs and the ability to identify behavioral and emotional symptoms associated with this vulnerable subset of the offender population. (PsycINFO Database Record (c) 2015 APA, all rights reserved).

  19. Suspect filler similarity in eyewitness lineups: a literature review and a novel methodology.

    PubMed

    Fitzgerald, Ryan J; Oriet, Chris; Price, Heather L

    2015-02-01

    Eyewitness lineups typically contain a suspect (guilty or innocent) and fillers (known innocents). The degree to which fillers should resemble the suspect is a complex issue that has yet to be resolved. Previously, researchers have voiced concern that eyewitnesses would be unable to identify their target from a lineup containing highly similar fillers; however, our literature review suggests highly similar fillers have only rarely been shown to have this effect. To further examine the effect of highly similar fillers on lineup responses, we used morphing software to create fillers of moderately high and very high similarity to the suspect. When the culprit was in the lineup, a higher correct identification rate was observed in moderately high similarity lineups than in very high similarity lineups. When the culprit was absent, similarity did not yield a significant effect on innocent suspect misidentification rates. However, the correct rejection rate in the moderately high similarity lineup was 20% higher than in the very high similarity lineup. When choosing rates were controlled by calculating identification probabilities for only those who made a selection from the lineup, culprit identification rates as well as innocent suspect misidentification rates were significantly higher in the moderately high similarity lineup than in the very high similarity lineup. Thus, very high similarity fillers yielded costs and benefits. Although our research suggests that selecting the most similar fillers available may adversely affect correct identification rates, we recommend additional research using fillers obtained from police databases to corroborate our findings.

  20. Response Covariation: The Relationship between Correct Academic Responding and Problem Behavior.

    ERIC Educational Resources Information Center

    Lalli, Joseph S.; Kates, Kelly; Casey, Sean D.

    1999-01-01

    Examines the relationship between the accuracy of academic responding and aggression for two boys with mild retardation. Aggression was highest during spelling instruction; an evaluation showed aggression was escape maintained. Changes in teaching formats resulted in increased posttest scores. Data showed that the rates of problem behavior…

  1. Discriminability and Sensitivity to Reinforcer Magnitude in a Detection Task

    ERIC Educational Resources Information Center

    Alsop, Brent; Porritt, Melissa

    2006-01-01

    Three pigeons discriminated between two sample stimuli (intensities of red light). The difficulty of the discrimination was varied over four levels. At each level, the relative reinforcer magnitude for the two correct responses was varied across conditions, and the reinforcer rates were equal. Within levels, discriminability between the sample…

  2. The association between work-related characteristic and job burnout among Chinese correctional officers: a cross-sectional survey.

    PubMed

    Hu, S; Wang, J-N; Liu, L; Wu, H; Yang, X; Wang, Y; Wang, L

    2015-09-01

    It is well known that job burnout is a major problem for many professions. Correctional officers, the most important driving force in correctional facilities, deal with unwilling and potentially violent populations, and this may lead to burnout. However, in China, few studies are available regarding burnout among correctional officers and associations with work-related factors. The aim of this study was to explore the impact of work characteristics on job burnout among Chinese correctional officers in public prisons. Cross-sectional survey. This cross-sectional study was performed in March/April 2011. The study population comprised 2185 correctional officers working in four prisons in a province in north-east China. A questionnaire that examined job burnout [three subscales: emotional exhaustion (EE), cynicism (CY) and professional efficacy (PE)], work conditions, occupational stress and demographic factors was distributed to these correctional officers. In total, 1769 responses were received (response rate 81%). Multiple logistic regression was used to explore the factors related to burnout. Mean (±standard deviation) scores were 10.59 ± 7.51 for EE, 9.65 ± 6.56 for CY and 23.90 ± 9.39 for PE. Strong extrinsic effort and reward were the most powerful predictors of job burnout; an imbalance between effort and reward at work and perceived threat was mainly associated with EE and CY, and strong overcommitment was mainly associated with EE and PE. Chinese correctional officers experience a slightly higher level of job burnout, and this is affected by work-related stress. It is important to reduce occupational stress in correctional officers and improve disadvantageous work conditions in order to reduce burnout in this population. Copyright © 2015 The Royal Society for Public Health. Published by Elsevier Ltd. All rights reserved.

  3. Does Mckuer's Law Hold for Heart Rate Control via Biofeedback Display?

    NASA Technical Reports Server (NTRS)

    Courter, B. J.; Jex, H. R.

    1984-01-01

    Some persons can control their pulse rate with the aid of a biofeedback display. If the biofeedback display is modified to show the error between a command pulse-rate and the measured rate, a compensatory (error correcting) heart rate tracking control loop can be created. The dynamic response characteristics of this control loop when subjected to step and quasi-random disturbances were measured. The control loop includes a beat-to-beat cardiotachmeter differenced with a forcing function from a quasi-random input generator; the resulting error pulse-rate is displayed as feedback. The subject acts to null the displayed pulse-rate error, thereby closing a compensatory control loop. McRuer's Law should hold for this case. A few subjects already skilled in voluntary pulse-rate control were tested for heart-rate control response. Control-law properties are derived, such as: crossover frequency, stability margins, and closed-loop bandwidth. These are evaluated for a range of forcing functions and for step as well as random disturbances.

  4. Watchkeeping Studies on a Nuclear Submarine

    DTIC Science & Technology

    1975-07-01

    degree of variability in performance occurs in response to the persisting diurnal rhythms, whereas in the latter, a degree of adaptation of these...charge of each of the three watches of 4 ratings was n’-de responsible for ensuring that these forms were correctly completed, T. whole ,erption was...of some 20-25 hours, the exact amour ,, depending on the individual’s personal sleep requirements. The 3-day sleep totals for each subject were

  5. Conceptual question response times in Peer Instruction classrooms

    NASA Astrophysics Data System (ADS)

    Miller, Kelly; Lasry, Nathaniel; Lukoff, Brian; Schell, Julie; Mazur, Eric

    2014-12-01

    Classroom response systems are widely used in interactive teaching environments as a way to engage students by asking them questions. Previous research on the time taken by students to respond to conceptual questions has yielded insights on how students think and change conceptions. We measure the amount of time students take to respond to in-class, conceptual questions [ConcepTests (CTs)] in two introductory physics courses taught using Peer Instruction and use item response theory to determine the difficulty of the CTs. We examine response time differences between correct and incorrect answers both before and after the peer discussion for CTs of varying difficulty. We also determine the relationship between response time and student performance on a standardized test of incoming physics knowledge, precourse self-efficacy, and gender. Our data reveal three results of interest. First, response time for correct answers is significantly faster than for incorrect answers, both before and after peer discussion, especially for easy CTs. Second, students with greater incoming physics knowledge and higher self-efficacy respond faster in both rounds. Third, there is no gender difference in response rate after controlling for incoming physics knowledge scores, although males register significantly more attempts before committing to a final answer than do female students. These results provide insight into effective CT pacing during Peer Instruction. In particular, in order to maintain a pace that keeps everyone engaged, students should not be given too much time to respond. When around 80% of the answers are in, the ratio of correct to incorrect responses rapidly approaches levels indicating random guessing and instructors should close the poll.

  6. Motivation modulates the P300 amplitude during brain-computer interface use.

    PubMed

    Kleih, S C; Nijboer, F; Halder, S; Kübler, A

    2010-07-01

    This study examined the effect of motivation as a possible psychological influencing variable on P300 amplitude and performance in a brain-computer interface (BCI) controlled by event-related potentials (ERP). Participants were instructed to copy spell a sentence by attending to cells of a randomly flashing 7*7 matrix. Motivation was manipulated by monetary reward. In two experimental groups participants received 25 (N=11) or 50 (N=11) Euro cent for each correctly selected character; the control group (N=11) was not rewarded. BCI performance was defined as the overall percentage of correctly selected characters (correct response rate=CRR). Participants performed at an average of 99%. At electrode location Cz the P300 amplitude was positively correlated to self-rated motivation. The P300 amplitude of the most motivated participants was significantly higher than that of the least motivated participants. Highly motivated participants were able to communicate correctly faster with the ERP-BCI than less motivated participants. Motivation modulates the P300 amplitude in an ERP-BCI. Motivation may contribute to variance in BCI performance and should be monitored in BCI settings. Copyright 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Implementation of false discovery rate for exploring novel paradigms and trait dimensions with ERPs.

    PubMed

    Crowley, Michael J; Wu, Jia; McCreary, Scott; Miller, Kelly; Mayes, Linda C

    2012-01-01

    False discovery rate (FDR) is a multiple comparison procedure that targets the expected proportion of false discoveries among the discoveries. Employing FDR methods in event-related potential (ERP) research provides an approach to explore new ERP paradigms and ERP-psychological trait/behavior relations. In Study 1, we examined neural responses to escape behavior from an aversive noise. In Study 2, we correlated a relatively unexplored trait dimension, ostracism, with neural response. In both situations we focused on the frontal cortical region, applying a channel by time plots to display statistically significant uncorrected data and FDR corrected data, controlling for multiple comparisons.

  8. Parkinson’s disease patients show impaired corrective grasp control and eye-hand coupling when reaching to grasp virtual objects

    PubMed Central

    Lukos, Jamie R.; Snider, Joseph; Hernandez, Manuel E.; Tunik, Eugene; Hillyard, Steven; Poizner, Howard

    2013-01-01

    The effect of Parkinson’s disease on hand-eye coordination and corrective response control during reach-to-grasp tasks remains unclear. Moderately impaired Parkinson’s disease patients (PD, n=9) and age-matched controls (n=12) reached to and grasped a virtual rectangular object, with haptic feedback provided to the thumb and index fingertip by two 3-degree of freedom manipulanda. The object rotated unexpectedly on a minority of trials, requiring subjects to adjust their grasp aperture. On half the trials, visual feedback of finger positions disappeared during the initial phase of the reach, when feedforward mechanisms are known to guide movement. PD patients were tested without (OFF) and with (ON) medication to investigate the effects of dopamine depletion and repletion on eye-hand coordination online corrective response control. We quantified eye-hand coordination by monitoring hand kinematics and eye position during the reach. We hypothesized that if the basal ganglia are important for eye-hand coordination and online corrections to object perturbations, then PD patients tested OFF medication would show reduced eye-hand spans and impoverished arm-hand coordination responses to the perturbation, which would be further exasperated when visual feedback of the hand was removed. Strikingly, PD patients tracked their hands with their gaze, and their movements became destabilized when having to make online corrective responses to object perturbations exhibiting pauses and changes in movement direction. These impairments largely remained even when tested in the ON state, despite significant improvement on the Unified Parkinson’s Disease Rating Scale. Our findings suggest that basal ganglia-cortical loops are essential for mediating eye-hand coordination and adaptive online responses for reach-to-grasp movements, and that restoration of tonic levels of dopamine may not be adequate to remediate this coordinative nature of basal ganglia modulated function. PMID:24056196

  9. Toward a more sophisticated response representation in theories of medial frontal performance monitoring: The effects of motor similarity and motor asymmetries.

    PubMed

    Hochman, Eldad Yitzhak; Orr, Joseph M; Gehring, William J

    2014-02-01

    Cognitive control in the posterior medial frontal cortex (pMFC) is formulated in models that emphasize adaptive behavior driven by a computation evaluating the degree of difference between 2 conflicting responses. These functions are manifested by an event-related brain potential component coined the error-related negativity (ERN). We hypothesized that the ERN represents a regulative rather than evaluative pMFC process, exerted over the error motor representation, expediting the execution of a corrective response. We manipulated the motor representations of the error and the correct response to varying degrees. The ERN was greater when 1) the error response was more potent than when the correct response was more potent, 2) more errors were committed, 3) fewer and slower corrections were observed, and 4) the error response shared fewer motor features with the correct response. In their current forms, several prominent models of the pMFC cannot be reconciled with these findings. We suggest that a prepotent, unintended error is prone to reach the manual motor processor responsible for response execution before a nonpotent, intended correct response. In this case, the correct response is a correction and its execution must wait until the error is aborted. The ERN may reflect pMFC activity that aimed to suppress the error.

  10. Learning time-dependent noise to reduce logical errors: real time error rate estimation in quantum error correction

    NASA Astrophysics Data System (ADS)

    Huo, Ming-Xia; Li, Ying

    2017-12-01

    Quantum error correction is important to quantum information processing, which allows us to reliably process information encoded in quantum error correction codes. Efficient quantum error correction benefits from the knowledge of error rates. We propose a protocol for monitoring error rates in real time without interrupting the quantum error correction. Any adaptation of the quantum error correction code or its implementation circuit is not required. The protocol can be directly applied to the most advanced quantum error correction techniques, e.g. surface code. A Gaussian processes algorithm is used to estimate and predict error rates based on error correction data in the past. We find that using these estimated error rates, the probability of error correction failures can be significantly reduced by a factor increasing with the code distance.

  11. 5 CFR 839.821 - Who is responsible for correcting my records?

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... § 839.821 Who is responsible for correcting my records? (a) Your current employer will correct your records in accordance with OPM instructions. Your employer must not delay correcting your records. (b) For... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Who is responsible for correcting my...

  12. Positive relationship between odor identification and affective responses of negatively valenced odors

    PubMed Central

    Martinec Nováková, Lenka; Plotěná, Dagmar; Roberts, S. Craig; Havlíček, Jan

    2015-01-01

    Hedonic ratings of odors and olfactory preferences are influenced by a number of modulating factors, such as prior experience and knowledge about an odor’s identity. The present study addresses the relationship between knowledge about an odor’s identity due to prior experience, assessed by means of a test of cued odor identification, and odor pleasantness ratings in children who exhibit ongoing olfactory learning. Ninety-one children aged 8–11 years rated the pleasantness of odors in the Sniffin’ Sticks test and, subsequently, took the odor identification test. A positive association between odor identification and pleasantness was found for two unpleasant food odors (garlic and fish): higher pleasantness ratings were exhibited by those participants who correctly identified these odors compared to those who failed to correctly identify them. However, we did not find a similar effect for any of the more pleasant odors. The results of this study suggest that pleasantness ratings of some odors may be modulated by the knowledge of their identity due to prior experience and that this relationship might be more evident in unpleasant odors. PMID:26029143

  13. A model-free method for mass spectrometer response correction. [for oxygen consumption and cardiac output calculation

    NASA Technical Reports Server (NTRS)

    Shykoff, Barbara E.; Swanson, Harvey T.

    1987-01-01

    A new method for correction of mass spectrometer output signals is described. Response-time distortion is reduced independently of any model of mass spectrometer behavior. The delay of the system is found first from the cross-correlation function of a step change and its response. A two-sided time-domain digital correction filter (deconvolution filter) is generated next from the same step response data using a regression procedure. Other data are corrected using the filter and delay. The mean squared error between a step response and a step is reduced considerably more after the use of a deconvolution filter than after the application of a second-order model correction. O2 consumption and CO2 production values calculated from data corrupted by a simulated dynamic process return to near the uncorrupted values after correction. Although a clean step response or the ensemble average of several responses contaminated with noise is needed for the generation of the filter, random noise of magnitude not above 0.5 percent added to the response to be corrected does not impair the correction severely.

  14. Prevalence of self-reported tuberculosis, knowledge about tuberculosis transmission and its determinants among adults in India: results from a nation-wide cross-sectional household survey.

    PubMed

    Sreeramareddy, Chandrashekhar T; Harsha Kumar, H N; Arokiasamy, John T

    2013-01-17

    Knowledge about symptoms and transmission of tuberculosis determines health seeking behavior and helps in prevention of tuberculosis transmission in the community. Such data is useful for policy makers to formulate information, education and communication strategies for tuberculosis control. A secondary data analysis of India demographic and health survey, 2005/6 was carried out. Questions about self-reported tuberculosis, transmission and curability of tuberculosis were analysed. Correct knowledge (without misconceptions) about tuberculosis transmission was used as a dependant variable and the explanatory variables tested were: demographic data, education, wealth quintiles, frequency of exposure to media and the curability of tuberculosis. Determinants of correct knowledge without misconceptions were tested by univariate and multivariate analyses using national weighting factor to adjust for complex sampling design. A total of 109,070 households (response rate of 93.5%) and 198,718 participants (response rate of 91.6%) completed the survey. The samples of men and women interviewed were 74,360 and 124,358 respectively. Prevalence rate of self-reported tuberculosis was 445 per 100,000 usual household residents and 4.60 per 1,000 participants. The number of respondents who had "heard of an illness called tuberculosis" was 177,423 (89.3%). Of these 47,487 (26.8%) participants did not know and 55.5% knew about the correct mode of tuberculosis transmission i.e. "Through the air when coughing or sneezing". The common misconceptions about transmission were "Through food" (32.4%), "Sharing utensils" (18.2%), and "Touching a person with tuberculosis" (12.3%). Only 52,617 (29.7%) participants had correct knowledge without misconceptions. Being male (aOR 1.17, 95% CIs 1.14, 1.21), being a Hindu (aOR 1.20, 95% CIs 1.14, 1.26) or Muslim (aOR 1.26, 95% CIs 1.18, 1.34), listening to radio (aOR 1.08, 95% CIs 1.04, 1.13) and "Tuberculosis can be cured" (aOR 1.47, 95% CIs 1.41, 1.53) were associated with correct knowledge without misconceptions. Knowledge about tuberculosis transmission is very poor and misconceptions still exist. Among the traditional mass media, the frequency of listening to radio was associated with correct knowledge about tuberculosis transmission. Strategies to deliver information, education and communication campaigns could be improved.

  15. A randomized, controlled trial to teach middle school children to recognize stroke and call 911: the kids identifying and defeating stroke project.

    PubMed

    Morgenstern, Lewis B; Gonzales, Nicole R; Maddox, Katherine E; Brown, Devin L; Karim, Asha P; Espinosa, Nina; Moyé, Lemuel A; Pary, Jennifer K; Grotta, James C; Lisabeth, Lynda D; Conley, Kathleen M

    2007-11-01

    Underutilization of acute stroke therapy is driven by delay to hospital arrival. We present the primary results of a pilot, randomized, controlled trial to encourage calling 911 for witnessed stroke among middle school children and their parents. This project occurred in Corpus Christi, an urban Texas community of 325,000. Three intervention and 3 control schools were randomly selected. The intervention contained 12 hours of classroom instruction divided among sixth, seventh, and eighth grades. Parents were educated indirectly through homework assignments. Two-sample t tests were used to compare pretest and posttest responses. Domain 1 test questions involved stroke pathophysiology. Intervention students improved from 29% to 34% correct; control students changed from 28% to 25%. Domain 2 test questions involved stroke symptom knowledge. Intervention school students changed from 28% correct to 43%; control school students answered 25% correctly on the pretest and 29% on the posttest. Domain 3 test questions involved what to do for witnessed stroke. Intervention school students answered 36% of questions correctly on the pretest and 54% correctly on the posttest, whereas control students changed from 32% correct to 34%. A comparison of change in the mean proportion correct over time between intervention and control students was P<0.001 for each of the 3 individual domains. A poor parental response rate impaired the ability to assess parental improvement. A scientific, theory-based, educational intervention can potentially improve intent to call 911 for stroke among middle school children. A different mechanism is needed to effectively diffuse the curriculum to parents.

  16. Singing Video Games May Help Improve Pitch-Matching Accuracy

    ERIC Educational Resources Information Center

    Paney, Andrew S.

    2015-01-01

    The purpose of this study was to investigate the effect of singing video games on the pitch-matching skills of undergraduate students. Popular games like "Rock Band" and "Karaoke Revolutions" rate players' singing based on the correctness of the frequency of their sung response. Players are motivated to improve their…

  17. Searching for answers to clinical questions using google versus evidence-based summary resources: a randomized controlled crossover study.

    PubMed

    Kim, Sarang; Noveck, Helaine; Galt, James; Hogshire, Lauren; Willett, Laura; O'Rourke, Kerry

    2014-06-01

    To compare the speed and accuracy of answering clinical questions using Google versus summary resources. In 2011 and 2012, 48 internal medicine interns from two classes at Rutgers University Robert Wood Johnson Medical School, who had been trained to use three evidence-based summary resources, performed four-minute computer searches to answer 10 clinical questions. Half were randomized to initiate searches for answers to questions 1 to 5 using Google; the other half initiated searches using a summary resource. They then crossed over and used the other resource for questions 6 to 10. They documented the time spent searching and the resource where the answer was found. Time to correct response and percentage of correct responses were compared between groups using t test and general estimating equations. Of 480 questions administered, interns found answers for 393 (82%). Interns initiating searches in Google used a wider variety of resources than those starting with summary resources. No significant difference was found in mean time to correct response (138.5 seconds for Google versus 136.1 seconds for summary resource; P = .72). Mean correct response rate was 58.4% for Google versus 61.5% for summary resource (mean difference -3.1%; 95% CI -10.3% to 4.2%; P = .40). The authors found no significant differences in speed or accuracy between searches initiated using Google versus summary resources. Although summary resources are considered to provide the highest quality of evidence, improvements to allow for better speed and accuracy are needed.

  18. Greek physicians' and dentists' compliance with the British society for antimicrobial chemotherapy (BSAC) guidelines for preventing bacterial endocarditis.

    PubMed

    Panos, G; Giamarellou, H; Papazachos, G; Birbilis, T; Toutouzas, P

    1996-08-01

    Two thousand questionnaires inquiring about applied prophylaxis for bacterial endocarditis were sent to practicing doctors in Greece. Two hundred and ninety-nine questionnaires were completed and returned (15% response rate) and were subsequently divided into two groups: Group A (163) consisting of responses from dentists, chest physicians and ear, nose and throat (ENT) specialists and group B (136) including responses from gastroenterologists, gynecologists, urologists and radiologists. The percentage of correct answers given in response by clinicians in Groups A and B to the main questions and in accordance with the 1992 guidelines of the British Society for Antimicrobial Chemotherapy (BSAC) were respectively: (a) 53% vs 35% asked patients their previous history pertaining to valve disease, rheumatic fever or prosthetic valve surgery; (b) 55% vs 33% administered prophylaxis to patients with relevant history prior to medical procedures; (c) 67% vs 0% of prescribing doctors administered the appropriate antibacterials; (d) 33% vs 31% initiated prophylaxis in proper timing prior to medical procedure; (e) 14% vs 13% administered antibiotics in correct time/route/duration of infusion where applicable, prior to medical procedure; (f) 7% of group A doctors administering recommended antibiotics, implemented prophylaxis with correct time/route/dosage while, although none of group B doctors administered recommended antibiotics, 7% implemented prophylaxis with correct time/route recommendations; (g) an overall 2% of doctors from both groups met the BSAC recommendations. In conclusion, it is imperative that the appropriate training of doctors in all subspecialties regarding prophylaxis of bacterial endocarditis and according to current recommendations be carried out.

  19. A pilot study of the Personality Assessment Inventory (PAI) in corrections: assessment of malingering, suicide risk, and aggression in male inmates.

    PubMed

    Wang, E W; Rogers, R; Giles, C L; Diamond, P M; Herrington-Wang, L E; Taylor, E R

    1997-01-01

    Provision of mental health services to correctional populations places considerable demands on clinical staff to provide efficient and effective means to screen patients for severe mental disorders and other emergent conditions that necessitate immediate interventions. Among the highly problematic behaviors found in correctional settings are forms of acting out (e.g., suicide and aggression towards others) and response style (e.g., motivations to malinger). The current study examined the usefulness of the Personality Assessment Inventory (PAI) in assessing problematic behaviors in a corrections-based psychiatric hospital. As evidence of criterion related validity, selected PAI scales were compared to (a) evidence of malingering on the Structured Interview of Reported Symptoms (SIRS), (b) suicidal threats and gestures, and (c) ratings of aggression on the Overt Aggression Scale (OAS). In general, results supported the use of the PAI for the assessment of these problematic behaviors.

  20. Small field detector correction factors: effects of the flattening filter for Elekta and Varian linear accelerators

    PubMed Central

    Liu, Paul Z.Y.; Lee, Christopher; McKenzie, David R.; Suchowerska, Natalka

    2016-01-01

    Flattening filter‐free (FFF) beams are becoming the preferred beam type for stereotactic radiosurgery (SRS) and stereotactic ablative radiation therapy (SABR), as they enable an increase in dose rate and a decrease in treatment time. This work assesses the effects of the flattening filter on small field output factors for 6 MV beams generated by both Elekta and Varian linear accelerators, and determines differences between detector response in flattened (FF) and FFF beams. Relative output factors were measured with a range of detectors (diodes, ionization chambers, radiochromic film, and microDiamond) and referenced to the relative output factors measured with an air core fiber optic dosimeter (FOD), a scintillation dosimeter developed at Chris O'Brien Lifehouse, Sydney. Small field correction factors were generated for both FF and FFF beams. Diode measured detector response was compared with a recently published mathematical relation to predict diode response corrections in small fields. The effect of flattening filter removal on detector response was quantified using a ratio of relative detector responses in FFF and FF fields for the same field size. The removal of the flattening filter was found to have a small but measurable effect on ionization chamber response with maximum deviations of less than ±0.9% across all field sizes measured. Solid‐state detectors showed an increased dependence on the flattening filter of up to ±1.6%. Measured diode response was within ±1.1% of the published mathematical relation for all fields up to 30 mm, independent of linac type and presence or absence of a flattening filter. For 6 MV beams, detector correction factors between FFF and FF beams are interchangeable for a linac between FF and FFF modes, providing that an additional uncertainty of up to ±1.6% is accepted. PACS number(s): 87.55.km, 87.56.bd, 87.56.Da PMID:27167280

  1. Hydrostatic Stress Effects Incorporated Into the Analysis of the High-Strain-Rate Deformation of Polymer Matrix Composites

    NASA Technical Reports Server (NTRS)

    Goldberg, Robert K.; Roberts, Gary D.

    2003-01-01

    Procedures for modeling the effect of high strain rate on composite materials are needed for designing reliable composite engine cases that are lighter than the metal cases in current use. The types of polymer matrix composites that are likely to be used in such an application have a deformation response that is nonlinear and that varies with strain rate. The nonlinearity and strain rate dependence of the composite response is primarily due to the matrix constituent. Therefore, in developing material models to be used in the design of impact-resistant composite engine cases, the deformation of the polymer matrix must be correctly analyzed. However, unlike in metals, the nonlinear response of polymers depends on the hydrostatic stresses, which must be accounted for within an analytical model. An experimental program has been carried out through a university grant with the Ohio State University to obtain tensile and shear deformation data for a representative polymer for strain rates ranging from quasi-static to high rates of several hundred per second. This information has been used at the NASA Glenn Research Center to develop, characterize, and correlate a material model in which the strain rate dependence and nonlinearity (including hydrostatic stress effects) of the polymer are correctly analyzed. To obtain the material data, Glenn s researchers designed and fabricated test specimens of a representative toughened epoxy resin. Quasi-static tests at low strain rates and split Hopkinson bar tests at high strain rates were then conducted at the Ohio State University. The experimental data confirmed the strong effects of strain rate on both the tensile and shear deformation of the polymer. For the analytical model, Glenn researchers modified state variable constitutive equations previously used for the viscoplastic analysis of metals to allow for the analysis of the nonlinear, strain-rate-dependent polymer deformation. Specifically, we accounted for the effects of hydrostatic stresses. An important discovery in the course of this work was that the hydrostatic stress effects varied during the loading process, which needed to be accounted for within the constitutive equations. The model is characterized primarily by shear data, with tensile data used to characterize the hydrostatic stress effects.

  2. Visual motion direction is represented in population-level neural response as measured by magnetoencephalography.

    PubMed

    Kaneoke, Y; Urakawa, T; Kakigi, R

    2009-05-19

    We investigated whether direction information is represented in the population-level neural response evoked by the visual motion stimulus, as measured by magnetoencephalography. Coherent motions with varied speed, varied direction, and different coherence level were presented using random dot kinematography. Peak latency of responses to motion onset was inversely related to speed in all directions, as previously reported, but no significant effect of direction on latency changes was identified. Mutual information entropy (IE) calculated using four-direction response data increased significantly (>2.14) after motion onset in 41.3% of response data and maximum IE was distributed at approximately 20 ms after peak response latency. When response waveforms showing significant differences (by multivariate discriminant analysis) in distribution of the three waveform parameters (peak amplitude, peak latency, and 75% waveform width) with stimulus directions were analyzed, 87 waveform stimulus directions (80.6%) were correctly estimated using these parameters. Correct estimation rate was unaffected by stimulus speed, but was affected by coherence level, even though both speed and coherence affected response amplitude similarly. Our results indicate that speed and direction of stimulus motion are represented in the distinct properties of a response waveform, suggesting that the human brain processes speed and direction separately, at least in part.

  3. Effects of concurrent physical and cognitive demands on muscle activity and heart rate variability in a repetitive upper-extremity precision task.

    PubMed

    Srinivasan, Divya; Mathiassen, Svend Erik; Hallman, David M; Samani, Afshin; Madeleine, Pascal; Lyskov, Eugene

    2016-01-01

    Most previous studies of concurrent physical and cognitive demands have addressed tasks of limited relevance to occupational work, and with dissociated physical and cognitive task components. This study investigated effects on muscle activity and heart rate variability of executing a repetitive occupational task with an added cognitive demand integral to correct task performance. Thirty-five healthy females performed 7.5 min of standardized repetitive pipetting work in a baseline condition and a concurrent cognitive condition involving a complex instruction for correct performance. Average levels and variabilities of electromyographic activities in the upper trapezius and extensor carpi radialis (ECR) muscles were compared between these two conditions. Heart rate and heart rate variability were also assessed to measure autonomic nervous system activation. Subjects also rated perceived fatigue in the neck-shoulder region, as well as exertion. Concurrent cognitive demands increased trapezius muscle activity from 8.2% of maximum voluntary exertion (MVE) in baseline to 9.0% MVE (p = 0.0005), but did not significantly affect ECR muscle activity, heart rate, heart rate variability, perceived fatigue or exertion. Trapezius muscle activity increased by about 10%, without any accompanying cardiovascular response to indicate increased sympathetic activation. We suggest this slight increase in trapezius muscle activity to be due to changed muscle activation patterns within or among shoulder muscles. The results suggest that it may be possible to introduce modest cognitive demands necessary for correct performance in repetitive precision work without any major physiological effects, at least in the short term.

  4. All-optical dynamic correction of distorted communication signals using a photorefractive polymeric hologram

    NASA Astrophysics Data System (ADS)

    Li, Guoqiang; Eralp, Muhsin; Thomas, Jayan; Tay, Savaş; Schülzgen, Axel; Norwood, Robert A.; Peyghambarian, N.

    2005-04-01

    All-optical real-time dynamic correction of wave front aberrations for image transmission is demonstrated using a photorefractive polymeric hologram. The material shows video rate response time with a low power laser. High-fidelity, high-contrast images can be reconstructed when the oil-filled phase plate generating atmospheric-like wave front aberrations is moved at 0.3mm/s. The architecture based on four-wave mixing has potential application in free-space optical communication, remote sensing, and dynamic tracking. The system offers a cost-effective alternative to closed-loop adaptive optics systems.

  5. Correcting false memories: Errors must be noticed and replaced.

    PubMed

    Mullet, Hillary G; Marsh, Elizabeth J

    2016-04-01

    Memory can be unreliable. For example, after reading The new baby stayed awake all night, people often misremember that the new baby cried all night (Brewer, 1977); similarly, after hearing bed, rest, and tired, people often falsely remember that sleep was on the list (Roediger & McDermott, 1995). In general, such false memories are difficult to correct, persisting despite warnings and additional study opportunities. We argue that errors must first be detected to be corrected; consistent with this argument, two experiments showed that false memories were nearly eliminated when conditions facilitated comparisons between participants' errors and corrective feedback (e.g., immediate trial-by-trial feedback that allowed direct comparisons between their responses and the correct information). However, knowledge that they had made an error was insufficient; unless the feedback message also contained the correct answer, the rate of false memories remained relatively constant. On the one hand, there is nothing special about correcting false memories: simply labeling an error as "wrong" is also insufficient for correcting other memory errors, including misremembered facts or mistranslations. However, unlike these other types of errors--which often benefit from the spacing afforded by delayed feedback--false memories require a special consideration: Learners may fail to notice their errors unless the correction conditions specifically highlight them.

  6. Are automatic postural responses in patients with Parkinson's disease abnormal due to their stooped posture?

    PubMed

    Bloem, B R; Beckley, D J; van Dijk, J G

    1999-02-01

    Abnormal automatic postural responses are thought to contribute to balance impairment in Parkinson's disease. However, because postural responses are modifiable by stance, we have speculated that some postural abnormalities in patients with Parkinson's disease are secondary to their stooped stance. We have studied this assumption by assessing automatic postural responses in 30 healthy subjects who were instructed either to stand upright or to assume a typical parkinsonian posture. During both conditions, subjects received 20 serial 4 degrees 'toe-up' rotational perturbations from a supporting forceplate. We recorded short-latency (SL) and medium-latency (ML) responses from stretched gastrocnemius muscles and long-latency (LL) responses from shortened tibialis anterior muscles. We also assessed changes in the center of foot pressure (CFP) and the center of gravity (COG). The results were qualitatively compared to a previously described group of patients with Parkinson's disease who, under these circumstances, typically have large ML responses, small LL responses and insufficient voluntary postural corrections, accompanied by a slow rate of backward CFP displacement and an increased posterior COG displacement. The stooped posture resulted in unloading of medial gastrocnemius muscles and loading of tibialis anterior muscles. Onset latencies of stretch responses in gastrocnemius muscles were delayed in stooped subjects, but the onset of LL responses was markedly reduced. Amplitudes of both ML and LL responses were reduced in stooped subjects. Prestimulus COG and, to a lesser extent, CFP were shifted forwards in stooped subjects. Posterior COG displacement and the rate of backward CFP displacement were diminished in stooped subjects. Voluntary postural corrections were unchanged while standing stooped. These results indicate that some postural abnormalities of patients with Parkinson's disease (most notably the reduced LL responses) can be reproduced in healthy subjects mimicking a stooped parkinsonian posture. Other postural abnormalities (most notably the increased ML responses and insufficient voluntary responses) did not appear in stooped controls and may contribute to balance impairment in Parkinson's disease.

  7. Response inhibition, preattentive processing, and sex difference in young children: an event-related potential study.

    PubMed

    Liu, Tongran; Xiao, Tong; Shi, Jiannong

    2013-02-13

    Response inhibition and preattentive processing are two important cognitive abilities for child development, and the current study adopted both behavioral and electrophysiological protocols to examine whether young children's response inhibition correlated with their preattentive processing. A Go/Nogo task was used to explore young children's response inhibition performances and an Oddball task with event-related potential recordings was used to measure their preattentive processing. The behavioral results showed that girls committed significantly fewer commission error rates, which showed that girls had stronger inhibition control abilities than boys. Girls also achieved higher d' scores in the Go/Nogo task, which indicated that they were more sensitive to the stimulus signals than boys. Although the electrophysiological results of preattentive processing did not show any sex differences, the correlation patterns between children's response inhibition and preattentive processing were different between these two groups: the neural response speed of preattentive processing (mismatch negativity peak latency) negatively correlated with girls' commission error rates and positively correlated with boys' correct hit rates. The current findings supported that the preattentive processing correlated with human inhibition control performances, and further showed that girls' better inhibition responses might be because of the influence of their preattentive processing.

  8. Interactions between scopolamine and muscarinic cholinergic agonists or cholinesterase inhibitors on spatial alternation performance in rats.

    PubMed

    Shannon, H E; Bemis, K G; Hendrix, J C; Ward, J S

    1990-12-01

    The effects on working memory of the muscarinic cholinergic agonists oxotremorine, arecoline, RS86 and pilocarpine, and the cholinesterase inhibitors physostigmine and tetrahydroaminoacadine were investigated in male F344 rats. Working memory was assessed by behavior maintained under a spatial alternation schedule of food presentation in which the interval between trials was varied from 2 to 32 sec. Under control conditions the percentage of correct responses decreased as the retention interval was varied from 2 to 32 sec. Administered alone the cholinergic agonists oxotremorine (0.01-0.1 mg/kg), arecoline (3-30 mg/kg), RS86 (0.3-3 mg/kg) and pilocarpine (0.3-3.0 mg/kg), and the cholinesterase inhibitors physostigmine (0.01-0.1 mg/kg) and tetrahydroaminoacridine (0.3-3.0 mg/kg) either had no effect on or produced dose-related deficits in working memory and decreases in response rates. The muscarinic antagonist scopolamine (0.1 mg/kg) produced retention interval-dependent decreases in the percentage of correct responding and rates of responding. The cholinergic agonists and tetrahydroaminoacridine failed to reverse the effects of scopolamine. However, physostigmine produced a dose-dependent reversal of the working-memory deficits and response-rate decreasing effects of scopolamine. The present results are consistent with the interpretation that drugs which primarily enhance M2 muscarinic cholinergic transmission are ineffective in enhancing working memory or in reversing scopolamine-induced deficits in working memory.

  9. 78 FR 78256 - Shared Responsibility Payment for Not Maintaining Minimum Essential Coverage; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... Shared Responsibility Payment for Not Maintaining Minimum Essential Coverage; Correction AGENCY: Internal... 5000A of the Internal Revenue Code for the shared responsibility payment for not maintaining minimum... language ``for shared responsibility payment for an'' is corrected to read ``for the shared responsibility...

  10. Electronic surveys: how to maximise success.

    PubMed

    McPeake, Joanne; Bateson, Meghan; O'Neill, Anna

    2014-01-01

    To draw on the researchers' experience of developing and distributing a UK-wide electronic survey. The evolution of electronic surveys in healthcare research will be discussed, as well as simple techniques that can be used to improve response rates for this type of data collection. There is an increasing use of electronic survey methods in healthcare research. However, in recent published research, electronic surveys have had lower response rates than traditional survey methods, such as postal and telephone surveys. This is a methodology paper. Electronic surveys have many advantages over traditional surveys, including a reduction in cost and ease of analysis. Drawbacks to this type of data collection include the potential for selection bias and poorer response rates. However, research teams can use a range of simple strategies to boost response rates. These approaches target the different stages of achieving a complete response: initial attraction through personalisation, engagement by having an easily accessible link to the survey, and transparency of survey length and completion though targeting the correct, and thereby interested, population. The fast, efficient and often 'free' electronic survey has many advantages over the traditional postal data collection method, including ease of analysis for what can be vast amounts of data. However, to capitalise on these benefits, researchers must carefully consider techniques to maximise response rates and minimise selection bias for their target population. Researchers can use a range of strategies to improve responses from electronic surveys, including sending up to three reminders, personalising each email, adding the updated response rate to reminder emails, and stating the average time it would take to complete the survey in the title of the email.

  11. Some effects of stress on users of a voice recognition system: A preliminary inquiry

    NASA Astrophysics Data System (ADS)

    French, B. A.

    1983-03-01

    Recent work with Automatic Speech Recognition has focused on applications and productivity considerations in the man-machine interface. This thesis is an attempt to see if placing users of such equipment under time-induced stress has an effect on their percent correct recognition rates. Subjects were given a message-handling task of fixed length and allowed progressively shorter times to attempt to complete it. Questionnaire responses indicate stress levels increased with decreased time-allowance; recognition rates decreased as time was reduced.

  12. Response to the Fernández-Niño Comments on Hernández-Alvarado et al. Increase in Suicide Rates by Hanging in the Population of Tabasco, México between 2003 and 2012. Int. J. Environ. Res. Public Health 2016, 13, 552.

    PubMed

    Hernández-Alvarado, Mervyn Manuel; González-Castro, Thelma Beatriz; Tovilla-Zárate, Carlos Alfonso; Fresán, Ana; Juárez-Rojop, Isela E; López-Narváez, María Lilia; Villar-Soto, Mario; Genis-Mendoza, Alma

    2016-07-01

    We thank the comments of Fernández-Niño [1] addressing our article [2] "Increase in Suicide Rates by Hanging in the Population of Tabasco, Mexico between 2003 and 2012", which pointed out that the use of the epidemiological concept "prevalence" is not correctly applied in the present manuscript.

  13. Should metacognition be measured by logistic regression?

    PubMed

    Rausch, Manuel; Zehetleitner, Michael

    2017-03-01

    Are logistic regression slopes suitable to quantify metacognitive sensitivity, i.e. the efficiency with which subjective reports differentiate between correct and incorrect task responses? We analytically show that logistic regression slopes are independent from rating criteria in one specific model of metacognition, which assumes (i) that rating decisions are based on sensory evidence generated independently of the sensory evidence used for primary task responses and (ii) that the distributions of evidence are logistic. Given a hierarchical model of metacognition, logistic regression slopes depend on rating criteria. According to all considered models, regression slopes depend on the primary task criterion. A reanalysis of previous data revealed that massive numbers of trials are required to distinguish between hierarchical and independent models with tolerable accuracy. It is argued that researchers who wish to use logistic regression as measure of metacognitive sensitivity need to control the primary task criterion and rating criteria. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Variations in Identification of Healthcare-Associated Infections

    PubMed Central

    Keller, Sara C.; Linkin, Darren R.; Fishman, Neil O.; Lautenbach, Ebbing

    2014-01-01

    OBJECTIVE Little is known about whether those performing healthcare-associated infection (HAI) surveillance vary in their interpretations of HAI definitions developed by the Centers for Disease Control and Prevention’s National Healthcare Safety Network (NHSN). Our primary objective was to characterize variations in these interpretations using clinical vignettes. We also describe predictors of variation in responses. DESIGN Cross-sectional study. SETTING United States. PARTICIPANTS A sample of US-based members of the Society for Healthcare Epidemiology of America (SHEA) Research Network. METHODS Respondents assessed whether each of 6 clinical vignettes met criteria for an NHSN-defined HAI. Individual- and institutional-level data were also gathered. RESULTS Surveys were distributed to 143 SHEA Research Network members from 126 hospitals. In total, 113 responses were obtained, representing at least 61 unique hospitals (30 respondents did not identify a hospital); 79.2% (84 of 106 nonmissing responses) were infection preventionists, and 79.4% (81 of 102 nonmissing responses) worked at academic hospitals. Among the 6 vignettes, the proportion of respondents correctly characterizing the vignettes was as low as 27.3%. Combining all 6 vignettes, the mean percentage of correct responses was 61.1% (95% confidence interval, 57.7%–63.8%). Percentage of correct responses was associated with presence of a clinical background (ie, nursing or physician degrees) but not with hospital size or infection prevention and control department characteristics. CONCLUSIONS Substantial heterogeneity exists in the application of HAI definitions in this survey of infection preventionists and hospital epidemiologists. Our data suggest a need to better clarify these definitions, especially when comparing HAI rates across institutions. PMID:23739071

  15. Evaluating four N2O emission algorithms in RZWQM2 in response to N rate on an irrigated corn field

    USDA-ARS?s Scientific Manuscript database

    Nitrous oxide (N2O) emissions from agricultural soils are major contributors to greenhouse gases. Correctly assessing the effects of the interactions between agricultural practices and environmental factors on N2O emissions is required for better crop and nitrogen (N) management. We used an enhanced...

  16. 77 FR 30819 - Endangered and Threatened Wildlife and Plants; Final Rule To Remove the Morelet's Crocodile From...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-23

    ... may vary by habitat, nutrition, etc. Our Response: We revised that section to reflect this correction..., nutrition, and other environmental factors (Rainwater 2011, pers. comm.) A growth rate of 0.63 inches (in... crocodile comprised the eastern coastal plain of Mexico, most of the Yucatan Peninsula, Belize, and northern...

  17. A Comparison of Newly-Trained and Experienced Raters on a Standardized Writing Assessment

    ERIC Educational Resources Information Center

    Attali, Yigal

    2016-01-01

    A short training program for evaluating responses to an essay writing task consisted of scoring 20 training essays with immediate feedback about the correct score. The same scoring session also served as a certification test for trainees. Participants with little or no previous rating experience completed this session and 14 trainees who passed an…

  18. Parameter Variability and Distributional Assumptions in the Diffusion Model

    ERIC Educational Resources Information Center

    Ratcliff, Roger

    2013-01-01

    If the diffusion model (Ratcliff & McKoon, 2008) is to account for the relative speeds of correct responses and errors, it is necessary that the components of processing identified by the model vary across the trials of a task. In standard applications, the rate at which information is accumulated by the diffusion process is assumed to be normally…

  19. Could Poor Parental Recall of HPV Vaccination Contribute to Low Vaccination Rates?

    PubMed

    Apte, Gauri; Pierre-Joseph, Natalie; Vercruysse, Jessica L; Perkins, Rebecca B

    2015-09-01

    Rates of initiation and completion of the human papillomavirus (HPV) vaccine series remain below national goals. Because parents are responsible for ensuring vaccination of their children, we examined the accuracy of parental recall of the number of shots their daughters received. Parents/guardians of girls aged 11 to 17 years were asked to recall the number of HPV doses received by their daughters. Dose number was confirmed using provider-verified medical records. Logistic regression assessed variables associated with correct recall. A total of 79 (63%) parents/guardians correctly identified the number of shots their daughters received. Ninety-one (73%) were aware of whether their daughter started the series at all. The only factor significantly associated with accurate recall in logistic regression models was female gender of parent/guardian. Nearly 40% of parents/guardians inaccurately recalled the number of HPV shots their children received, which may contribute to low rates of vaccine initiation and completion. © The Author(s) 2015.

  20. Healthcare Professionals' Knowledge of Influenza and Influenza Vaccination: Results of a National Survey in Poland.

    PubMed

    Kuchar, Ernest; Ludwikowska, Kamila; Antczak, Adam; Nitsch-Osuch, Aneta

    2018-01-01

    In Poland, the seasonal influenza vaccination rate is just barely 3% which may be related to the unsatisfactory knowledge of influenza among healthcare professionals, poor recognition of the benefits of influenza immunization and the fear of side effects. To address these issues, we surveyed healthcare professionals through an online questionnaire consisting of 18 closed-ended items. The questionnaire was completed by 495 healthcare professionals, mostly physicians (83%). The results revealed gaps in the knowledge concerning influenza diagnosis, complications, risk groups, and prognostic factors. On average, respondents only answered 4.8 of the 18 questions correctly (27%). Only 10% of respondents passed the threshold of 50% correct answers. The knowledge of contraindications to vaccination far outweighed the knowledge of indications for vaccination. Poor knowledge with a focus on the adverse effects of immunization may be a significant factor responsible for the low vaccination rate in Poland. To increase vaccination rate, healthcare professionals need to be educated about influenza-related risks and benefits of vaccination.

  1. Essays in applied macroeconomics: Asymmetric price adjustment, exchange rate and treatment effect

    NASA Astrophysics Data System (ADS)

    Gu, Jingping

    This dissertation consists of three essays. Chapter II examines the possible asymmetric response of gasoline prices to crude oil price changes using an error correction model with GARCH errors. Recent papers have looked at this issue. Some of these papers estimate a form of error correction model, but none of them accounts for autoregressive heteroskedasticity in estimation and testing for asymmetry and none of them takes the response of crude oil price into consideration. We find that time-varying volatility of gasoline price disturbances is an important feature of the data, and when we allow for asymmetric GARCH errors and investigate the system wide impulse response function, we find evidence of asymmetric adjustment to crude oil price changes in weekly retail gasoline prices. Chapter III discusses the relationship between fiscal deficit and exchange rate. Economic theory predicts that fiscal deficits can significantly affect real exchange rate movements, but existing empirical evidence reports only a weak impact of fiscal deficits on exchange rates. Based on US dollar-based real exchange rates in G5 countries and a flexible varying coefficient model, we show that the previously documented weak relationship between fiscal deficits and exchange rates may be the result of additive specifications, and that the relationship is stronger if we allow fiscal deficits to impact real exchange rates non-additively as well as nonlinearly. We find that the speed of exchange rate adjustment toward equilibrium depends on the state of the fiscal deficit; a fiscal contraction in the US can lead to less persistence in the deviation of exchange rates from fundamentals, and faster mean reversion to the equilibrium. Chapter IV proposes a kernel method to deal with the nonparametric regression model with only discrete covariates as regressors. This new approach is based on recently developed least squares cross-validation kernel smoothing method. It can not only automatically smooth the irrelevant variables out of the nonparametric regression model, but also avoid the problem of loss of efficiency related to the traditional nonparametric frequency-based method and the problem of misspecification based on parametric model.

  2. 34 CFR 200.49 - SEA responsibilities for school improvement, corrective action, and restructuring.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 34 Education 1 2010-07-01 2010-07-01 false SEA responsibilities for school improvement, corrective... Agencies Lea and School Improvement § 200.49 SEA responsibilities for school improvement, corrective action... subject to corrective action on January 7, 2002, the SEA must ensure that the LEA for that school provides...

  3. Assessment of Rapid-Blood-Culture-Identification Result Interpretation and Antibiotic Prescribing Practices

    PubMed Central

    Campbell, W. Scott; Lyden, Elizabeth; Van Schooneveld, Trevor C.

    2017-01-01

    ABSTRACT Rapid pathogen identification can alter antibiotic prescribing practices if interpreted correctly. Microbiology reporting can be difficult to understand, and new technology has made it more challenging. Nebraska Medicine recently implemented the BioFire FilmArray blood culture identification panel (BCID) coupled with stewardship-based education on interpretation. Physician BCID result interpretation and prescribing were assessed via an electronic survey, with a response rate of 40.8% (156/382 surveys). Seven questions required respondents to interpret BCID results, identify the most likely pathogen, and then choose therapy based on the results. The tallied correct responses resulted in a knowledge score. General linear models evaluated the effect of role, specialty, and utilization of the BCID interpretation guide on the mean knowledge score. The specialties of the respondents included 55.7% internal medicine, 19.7% family medicine, and 24.6% other. Roles included 41.1% residents, 5.0% fellows, and 53.9% faculty. Most reported that they reviewed antimicrobial susceptibility results (89.4%) and adjusted therapy accordingly (81.6%), while only 60% stated that they adjusted therapy based on BCID results. The correct response rates ranged from 52 to 86% for the interpretation questions. The most common errors included misinterpretation of Enterobacteriaceae and Staphylococcus genus results. Neither role nor specialty was associated with total knowledge score in multivariate analysis (P = 0.13 and 0.47, respectively). In conclusion, physician interpretation of BCID results is suboptimal and can result in ineffective treatment or missed opportunity to narrow therapy. With the implementation of new technology, improved reporting practices of BCID results with clinical decision support tools providing interpretation guidance available at the point of care is recommended. PMID:28250000

  4. Evidence for using Monte Carlo calculated wall attenuation and scatter correction factors for three styles of graphite-walled ion chamber.

    PubMed

    McCaffrey, J P; Mainegra-Hing, E; Kawrakow, I; Shortt, K R; Rogers, D W O

    2004-06-21

    The basic equation for establishing a 60Co air-kerma standard based on a cavity ionization chamber includes a wall correction term that corrects for the attenuation and scatter of photons in the chamber wall. For over a decade, the validity of the wall correction terms determined by extrapolation methods (K(w)K(cep)) has been strongly challenged by Monte Carlo (MC) calculation methods (K(wall)). Using the linear extrapolation method with experimental data, K(w)K(cep) was determined in this study for three different styles of primary-standard-grade graphite ionization chamber: cylindrical, spherical and plane-parallel. For measurements taken with the same 60Co source, the air-kerma rates for these three chambers, determined using extrapolated K(w)K(cep) values, differed by up to 2%. The MC code 'EGSnrc' was used to calculate the values of K(wall) for these three chambers. Use of the calculated K(wall) values gave air-kerma rates that agreed within 0.3%. The accuracy of this code was affirmed by its reliability in modelling the complex structure of the response curve obtained by rotation of the non-rotationally symmetric plane-parallel chamber. These results demonstrate that the linear extrapolation technique leads to errors in the determination of air-kerma.

  5. [Educational usefulness of lung auscultation training with an auscultation simulator].

    PubMed

    Arimura, Yasuji; Komatsu, Hiroyuki; Yanagi, Shigehisa; Matsumoto, Nobuhiro; Okayama, Akihiko; Hayashi, Katsuhiro; Nakazato, Masamitsu

    2011-06-01

    We examined the educational usefulness of lung auscultation training with an auscultation simulator "Mr. Lung". Auscultation training was conducted for fifth-year students of the Medical Department of the University of Miyazaki, and consisted of a lecture by a pulmonologist (Board Certified Member of the Japanese Respiratory Society) and skill training using Mr. Lung for a total of 90 min. We compared the percentages of students who correctly identified 4 adventitious sounds before and after training. We also investigated the responses to a self-report questionnaire on self-evaluation after training, auscultation experiences before training, and opinions regarding medical education with the simulator. The subjects' correct answer rate before training was 40% or less and that for the correct identification of rhonchi was the lowest (5%). The correct answer rate, which was not influenced by previous experience of auscultation, significantly increased after training (80% or more). In the self-report questionnaire, about 90% of the students answered that the ability to identify lung sounds by auscultation was necessary for all doctors and that the simulator was effective for acquiring this skill. The auscultation simulator may be useful for medical students not only to enhance auscultatory skills but also to realize the importance of auscultation in clinical examination.

  6. Dupuytren contracture recurrence following treatment with collagenase clostridium histolyticum (CORDLESS study): 3-year data.

    PubMed

    Peimer, Clayton A; Blazar, Philip; Coleman, Stephen; Kaplan, F Thomas D; Smith, Ted; Tursi, James P; Cohen, Brian; Kaufman, Gregory J; Lindau, Tommy

    2013-01-01

    To evaluate long-term efficacy and safety of collagenase clostridium histolyticum (CCH) after the third year of a 5-year nontreatment follow-up study, Collagenase Option for Reduction of Dupuytren Long-Term Evaluation of Safety Study. This study enrolled Dupuytren contracture patients from 5 previous clinical studies. Beginning 2 years after their first CCH injection, we re-evaluated patients annually for joint contracture and safety. Recurrence in a previously successfully treated joint (success = 0° to 5° contracture after CCH administration) was defined as 20° or greater worsening in contracture in the presence of a palpable cord or medical/surgical intervention to correct new or worsening contracture. We assessed partially corrected joints (joints reduced 20° or more from baseline contracture but not to 0° to 5°) for nondurable response, also defined as 20° or greater worsening of contracture or medical/surgical intervention. Of 1,080 CCH-treated joints (648 metacarpophalangeal [MCP]; 432 proximal interphalangeal [PIP]; n = 643 patients), 623 (451 MCP, 172 PIP) had achieved 0° to 5° contracture in the original study. Of these joints, 35% (217 of 623) recurred (MCP 27%; PIP 56%). Of these recurrences, an intervention was performed in 7%. Of the 1,080 CCH-treated joints, 301 were partially corrected in the original study. Of these, 50% (150 of 301; MCP: 38% [57 of 152]; PIP: 62% [93 of 149]) had nondurable response. We identified no new long-term or serious adverse events attributed to CCH during follow-up. Anti-clostridial type I collagenase and/or anti-clostridial type II collagenase antibodies were reported for 96% or more of patients who received 2 or more CCH injections and 82% who received 1 injection. The recurrence rate, which is comparable to other standard treatments, and the absence of long-term adverse events 3 years after initial treatment indicate that CCH is an effective and safe treatment for Dupuytren contracture. Most successfully treated joints had a contracture well below the threshold for surgical intervention 3 years after treatment. Recurrence rates among successfully treated joints were lower than nondurable response rates among partially corrected joints. Therapeutic IV. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. How Question Types Reveal Student Thinking: An Experimental Comparison of Multiple-True-False and Free-Response Formats.

    PubMed

    Hubbard, Joanna K; Potts, Macy A; Couch, Brian A

    2017-01-01

    Assessments represent an important component of undergraduate courses because they affect how students interact with course content and gauge student achievement of course objectives. To make decisions on assessment design, instructors must understand the affordances and limitations of available question formats. Here, we use a crossover experimental design to identify differences in how multiple-true-false (MTF) and free-response (FR) exam questions reveal student thinking regarding specific conceptions. We report that correct response rates correlate across the two formats but that a higher percentage of students provide correct responses for MTF questions. We find that MTF questions reveal a high prevalence of students with mixed (correct and incorrect) conceptions, while FR questions reveal a high prevalence of students with partial (correct and unclear) conceptions. These results suggest that MTF question prompts can direct students to address specific conceptions but obscure nuances in student thinking and may overestimate the frequency of particular conceptions. Conversely, FR questions provide a more authentic portrait of student thinking but may face limitations in their ability to diagnose specific, particularly incorrect, conceptions. We further discuss an intrinsic tension between question structure and diagnostic capacity and how instructors might use multiple formats or hybrid formats to overcome these obstacles. © 2017 J. K. Hubbard et al. CBE—Life Sciences Education © 2017 The American Society for Cell Biology. This article is distributed by The American Society for Cell Biology under license from the author(s). It is available to the public under an Attribution–Noncommercial–Share Alike 3.0 Unported Creative Commons License (http://creativecommons.org/licenses/by-nc-sa/3.0).

  8. Using the regulation of accuracy to study performance when the correct answer is not known.

    PubMed

    Luna, Karlos; Martín-Luengo, Beatriz

    2017-08-01

    We examined memory performance in multiple-choice questions when correct answers were not always present. How do participants answer when they are aware that the correct alternative may not be present? To answer this question we allowed participants to decide on the number of alternatives in their final answer (the plurality option), and whether they wanted to report or withhold their answer (report option). We also studied the memory benefits when both the plurality and the report options were available. In two experiments participants watched a crime and then answered questions with five alternatives. Half of the questions were presented with the correct alternative and half were not. Participants selected one alternative and rated confidence, then selected three alternatives and again rated confidence, and finally indicated whether they preferred the answer with one or with three alternatives (plurality option). Lastly, they decided whether to report or withhold the answer (report option). Results showed that participants' confidence in their selections was higher, that they chose more single answers, and that they preferred to report more often when the correct alternative was presented. We also attempted to classify a posteriori questions as either presented with or without the correct alternative from participants' selection. Classification was better than chance, and encouraging, but the forensic application of the classification technique is still limited since there was a large percentage of responses that were incorrectly classified. Our results also showed that the memory benefits of both plurality and report options overlap. © 2017 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  9. Compression of digital images over local area networks. Appendix 1: Item 3. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Gorjala, Bhargavi

    1991-01-01

    Differential Pulse Code Modulation (DPCM) has been used with speech for many years. It has not been as successful for images because of poor edge performance. The only corruption in DPC is quantizer error but this corruption becomes quite large in the region of an edge because of the abrupt changes in the statistics of the signal. We introduce two improved DPCM schemes; Edge correcting DPCM and Edge Preservation Differential Coding. These two coding schemes will detect the edges and take action to correct them. In an Edge Correcting scheme, the quantizer error for an edge is encoded using a recursive quantizer with entropy coding and sent to the receiver as side information. In an Edge Preserving scheme, when the quantizer input falls in the overload region, the quantizer error is encoded and sent to the receiver repeatedly until the quantizer input falls in the inner levels. Therefore these coding schemes increase the bit rate in the region of an edge and require variable rate channels. We implement these two variable rate coding schemes on a token wing network. Timed token protocol supports two classes of messages; asynchronous and synchronous. The synchronous class provides a pre-allocated bandwidth and guaranteed response time. The remaining bandwidth is dynamically allocated to the asynchronous class. The Edge Correcting DPCM is simulated by considering the edge information under the asynchronous class. For the simulation of the Edge Preserving scheme, the amount of information sent each time is fixed, but the length of the packet or the bit rate for that packet is chosen depending on the availability capacity. The performance of the network, and the performance of the image coding algorithms, is studied.

  10. Clinical comparison between two hyaluronic acid-derived fillers in the treatment of nasolabial folds in Chinese subjects: BioHyalux versus Restylane.

    PubMed

    Wu, Yan; Sun, Nan; Xu, Yue; Liu, Huixian; Zhong, Shaomin; Chen, Liyang; Li, Dong

    2016-04-01

    Hyaluronic acid fillers are used to improve the appearance of nasolabial folds (NLF). This study aimed to compare the efficacy, safety, and durability of a new hyaluronic acid gel (BioHyalux) versus Restylane for the correction of NLF. This was a multicenter, double-blinded, randomized, controlled, non-inferiority clinical trial involving 88 subjects with moderate to severe NLF. Subjects were randomized to BioHyalux and Restylane on either sides of the NLF. NLF was assessed before and right after injection, and at 1 week, 1, 3, and 6 months. Patients were followed up for 13-15 months to evaluate the durability and long-term safety. A clinically meaningful response was predefined as at least one-point improvement on the Wrinkle Severity Rating Scale, which is a five-point scale. At 6 months, the response rate of BioHyalux was not inferior to that of Restylane (P < 0.05). At the 13-15 months follow-up, the response rate by investigators was 58.0 % on the BioHyalux side versus 63.8 % on the Restylane side. The response rate by subjects showed similar results, which was 56.5 % on the BioHyalux side versus 60.9 % on the Restylane side at 13-15 months. The subjects' Global Aesthetic Improvement Scale (GAIS) showed that most subjects felt improvements on both sides of NLF (P > 0.05) at all time points. At 6 months, 100 % reported improvements on both side; at 13-15 months, 60 % of subjects reported improvements with BioHyalux versus 64 % with Restylane. Adverse events were transient and predominantly mild or moderate in severity including injection site swelling, pain, itching, bruising, and tenderness. BioHyalux had reliable safety and tolerance, and could be an effective injectable filler for correcting NLF.

  11. Breath-hold duration in man and the diving response induced by face immersion.

    PubMed

    Sterba, J A; Lundgren, C E

    1988-09-01

    The objective of this study in 5 selected volunteer subjects was to see whether the circulatory diving response which is elicited by breath holding and by cold water on the face would affect the duration of maximal-effort breath holds. Compared to control measurements (breath holding during resting, breathing with 35 degrees C water on the face) breath holding with the face cooled by 20 degrees C water caused a 12% reduction of heart rate, 6% reduction of cardiac output, 33% reduction in [corrected] forearm blood flow, and 9% rise in mean arterial blood pressure, but there was no difference in breath-hold duration (control and experimental both 94 s). There were also no differences in time of appearance of the first involuntary respiratory efforts during breath holding, in alveolar gas exchange, or in breaking-point alveolar O2 and CO2 tensions. When the diving response was magnified by a brief bout of exercise so that there was a 19% [corrected] reduction in heart rate, 23% reduction in cardiac output, and 48% reduction in forearm blood flow, breath-hold duration was still unaffected by face cooling. Compared to intermittent immersions, continuous exposure of the face to cold water abolished the diving response, probably by a cold adaptation of facial thermal receptors. These results with cooling of the face only are consistent with our earlier finding that there was a negative correlation between the duration of a maximal-effort breath hold and the diving response during whole-body submersion in cold water.

  12. Effects of hypnosis and level of processing on repeated recall of line drawings.

    PubMed

    McKelvie, S J; Pullara, M

    1988-07-01

    Moderately susceptible subjects (N = 30) initially judged 30 line drawings of objects for pleasantness (deep processing) and 30 line drawings for visual complexity (shallow processing), after which they were given two immediate recall tests. Following a 48-hr delay, subjects were allocated randomly to hypnosis, simulation, or neutral control conditions and were tested four more times. Subjects produced more correct and incorrect responses over the six trials and gave a higher number of correct responses for deep items than for shallow items. Over the last four trials, hypnosis had no general facilitative effect relative to the other two treatments, but the effect of depth was strongest for hypnotized subjects, who recalled more deep items than did the controls. Finally, both hypnotized and simulating subjects rated their recall as more involuntary and their experimental treatment as more helpful than did the controls. Caution is urged in the forensic use of hypnosis as a retrieval device.

  13. Hypnotic clever hands: Agency and automatic responding.

    PubMed

    Polito, Vince; Barnier, Amanda J; Connors, Michael H

    2018-06-01

    The Clever Hands task (Wegner, Fuller, & Sparrow, 2003) is a behavioral illusion in which participants make responses to a trivia quiz for which they have no sense of agency. Sixty high hypnotizable participants completed two versions of the Clever Hands task. Quiz One was a replication of the original study. Quiz Two was a hypnotic adaptation using three suggestions that were based on clinical disruptions to the sense of agency. The suggestions were for: random responding, thought insertion, and alien control. These suggestions led to differences in accuracy (action production) and estimates of accuracy (action projection). Specifically, whereas the random responding suggestion had little effect, the two clinically based suggestions had opposite impacts on action production: the thought insertion suggestion led to an increase in the rate of correct responses (although participants still believed they were responding randomly); while the alien control suggestion led to a reduction in the rate of correct answers and a pattern of results that more closely approximated randomness. Contrary to theoretical accounts that claim that hypnosis affects executive monitoring rather than executive control, this result indicates that specific hypnotic suggestions can also influence the implicit processes involved in action production. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  14. 30 CFR 1227.501 - What are a State's responsibilities to ensure that reporters correct erroneous data?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., incorrect lease/agreement numbers, and missing data fields; (c) Submit accepted and corrected lines to ONRR... that reporters correct erroneous data? 1227.501 Section 1227.501 Mineral Resources OFFICE OF SURFACE... responsibilities to ensure that reporters correct erroneous data? To ensure the correction of erroneous data, you...

  15. A diamond detector in the dosimetry of high-energy electron and photon beams.

    PubMed

    Laub, W U; Kaulich, T W; Nüsslin, F

    1999-09-01

    A diamond detector type 60003 (PTW Freiburg) was examined for the purpose of dosimetry with 4-20 MeV electron beams and 4-25 MV photon beams. Results were compared with those obtained by using a Markus chamber for electron beams and an ionization chamber for photon beams. Dose distributions were measured in a water phantom with the detector connected to a Unidos electrometer (PTW Freiburg). After a pre-irradiation of about 5 Gy the diamond detector shows a stability in response which is better than that of an ionization chamber. The current of the diamond detector was measured under variation of photon beam dose rate between 0.1 and 7 Gy min(-1). Different FSDs were chosen. Furthermore the pulse repetition frequency and the depth of the detector were changed. The electron beam dose rate was varied between 0.23 and 4.6 Gy min(-1) by changing the pulse-repetition frequency. The response shows no energy dependence within the covered photon-beam energy range. Between 4 MeV and 18 MeV electron beam energy it shows only a small energy dependence of about 2%, as expected from theory. For smaller electron energies the response increases significantly and an influence of the contact material used for the diamond detector can be surmised. A slight sublinearity of the current and dose rate was found. Detector current and dose rate are related by the expression i alpha Ddelta, where i is the detector current, D is the dose rate and delta is a correction factor of approximately 0.963. Depth-dose curves of photon beams, measured with the diamond detector, show a slight overestimation compared with measurements with the ionization chamber. This overestimation is compensated for by the above correction term. The superior spatial resolution of the diamond detector leads to minor deviations between depth-dose curves of electron beams measured with a Markus chamber and a diamond detector.

  16. Calling 911 in response to stroke: a nationwide study assessing definitive individual behavior.

    PubMed

    Mikulík, Robert; Bunt, Laura; Hrdlicka, Daniel; Dusek, Ladislav; Václavík, Daniel; Kryza, Jirí

    2008-06-01

    Stroke treatment is time-dependent, yet no study has systematically examined response to individual stroke symptoms in the general population. This nationwide study identifies which specific factors prompt correct response (calling 911) to stroke. Between November and December of 2005, a survey using a 3-stage random-sampling method including area, household, and household member sampling was conducted throughout the Czech Republic. Participants >40 years old were personally interviewed via a structured and standardized questionnaire concerning general knowledge and correct response to stroke as assessed by the Stroke Action Test (STAT). Predictors of scoring >50% on STAT were identified by multiple regression. A total of 650 households were contacted, yielding 592 interviews (response rate 91%). Mean age was 58+/-12, 55% women. Sixty-nine percent thought stroke was serious condition, and 57% thought it could be treated. Also 54% correctly named >/=2 risk factors, and 46% named >/=2 warning signs. Eighteen percent of respondents scored >50% on STAT. The predictors of such a score were age (for each 10-year increment, OR 1.4, 95% CI 1.2 to 1.7), secondary school education (OR 1.7, 95% CI 1.1 to 2.6), knowing that stroke is a serious disease (OR 1.8, 95% CI 1.1 to 3.1), and knowing that stroke is treatable (OR 2.0, 95% CI 1.2 to 3.2). Knowledge about stroke in the Czech Republic was fair, yet response to warning signs was poor. Our study is the first to identify that calling 911 was influenced by knowledge that stroke is a serious and treatable disease and not by recognition of symptoms.

  17. Quantum Kramers model: Corrections to the linear response theory for continuous bath spectrum

    NASA Astrophysics Data System (ADS)

    Rips, Ilya

    2017-01-01

    Decay of the metastable state is analyzed within the quantum Kramers model in the weak-to-intermediate dissipation regime. The decay kinetics in this regime is determined by energy exchange between the unstable mode and the stable modes of thermal bath. In our previous paper [Phys. Rev. A 42, 4427 (1990), 10.1103/PhysRevA.42.4427], Grabert's perturbative approach to well dynamics in the case of the discrete bath [Phys. Rev. Lett. 61, 1683 (1988), 10.1103/PhysRevLett.61.1683] has been extended to account for the second order terms in the classical equations of motion (EOM) for the stable modes. Account of the secular terms reduces EOM for the stable modes to those of the forced oscillator with the time-dependent frequency (TDF oscillator). Analytic expression for the characteristic function of energy loss of the unstable mode has been derived in terms of the generating function of the transition probabilities for the quantum forced TDF oscillator. In this paper, the approach is further developed and applied to the case of the continuous frequency spectrum of the bath. The spectral density functions of the bath of stable modes are expressed in terms of the dissipative properties (the friction function) of the original bath. They simplify considerably for the one-dimensional systems, when the density of phonon states is constant. Explicit expressions for the fourth order corrections to the linear response theory result for the characteristic function of the energy loss and its cumulants are obtained for the particular case of the cubic potential with Ohmic (Markovian) dissipation. The range of validity of the perturbative approach in this case is determined (γ /ωb<0.26 ), which includes the turnover region. The dominant correction to the linear response theory result is associated with the "work function" and leads to reduction of the average energy loss and its dispersion. This reduction increases with the increasing dissipation strength (up to ˜10 % ) within the range of validity of the approach. We have also calculated corrections to the depopulation factor and the escape rate for the quantum and for the classical Kramers models. Results for the classical escape rate are in very good agreement with the numerical simulations for high barriers. The results can serve as an additional proof of the robustness and accuracy of the linear response theory.

  18. Quantum Kramers model: Corrections to the linear response theory for continuous bath spectrum.

    PubMed

    Rips, Ilya

    2017-01-01

    Decay of the metastable state is analyzed within the quantum Kramers model in the weak-to-intermediate dissipation regime. The decay kinetics in this regime is determined by energy exchange between the unstable mode and the stable modes of thermal bath. In our previous paper [Phys. Rev. A 42, 4427 (1990)PLRAAN1050-294710.1103/PhysRevA.42.4427], Grabert's perturbative approach to well dynamics in the case of the discrete bath [Phys. Rev. Lett. 61, 1683 (1988)PRLTAO0031-900710.1103/PhysRevLett.61.1683] has been extended to account for the second order terms in the classical equations of motion (EOM) for the stable modes. Account of the secular terms reduces EOM for the stable modes to those of the forced oscillator with the time-dependent frequency (TDF oscillator). Analytic expression for the characteristic function of energy loss of the unstable mode has been derived in terms of the generating function of the transition probabilities for the quantum forced TDF oscillator. In this paper, the approach is further developed and applied to the case of the continuous frequency spectrum of the bath. The spectral density functions of the bath of stable modes are expressed in terms of the dissipative properties (the friction function) of the original bath. They simplify considerably for the one-dimensional systems, when the density of phonon states is constant. Explicit expressions for the fourth order corrections to the linear response theory result for the characteristic function of the energy loss and its cumulants are obtained for the particular case of the cubic potential with Ohmic (Markovian) dissipation. The range of validity of the perturbative approach in this case is determined (γ/ω_{b}<0.26), which includes the turnover region. The dominant correction to the linear response theory result is associated with the "work function" and leads to reduction of the average energy loss and its dispersion. This reduction increases with the increasing dissipation strength (up to ∼10%) within the range of validity of the approach. We have also calculated corrections to the depopulation factor and the escape rate for the quantum and for the classical Kramers models. Results for the classical escape rate are in very good agreement with the numerical simulations for high barriers. The results can serve as an additional proof of the robustness and accuracy of the linear response theory.

  19. Increased age and race-specific incidence of cervical cancer after correction for hysterectomy prevalence in the United States from 2000 to 2009.

    PubMed

    Rositch, Anne F; Nowak, Rebecca G; Gravitt, Patti E

    2014-07-01

    Invasive cervical cancer is thought to decline in women over 65 years old, the age at which cessation of routine cervical cancer screening is recommended. However, national cervical cancer incidence rates do not account for the high prevalence of hysterectomy in the United States. Using estimates of hysterectomy prevalence from the Behavioral Risk Factor Surveillance System (BRFSS), hysterectomy-corrected age-standardized and age-specific incidence rates of cervical cancer were calculated from the Surveillance, Epidemiology, and End Results (SEER) 18 registry in the United States from 2000 to 2009. Trends in corrected cervical cancer incidence across age were analyzed using Joinpoint regression. Unlike the relative decline in uncorrected rates, corrected rates continue to increase after age 35-39 (APC(CORRECTED) = 10.43) but at a slower rate than in 20-34 years (APC(CORRECTED) = 161.29). The highest corrected incidence was among 65- to 69-year-old women, with a rate of 27.4 cases per 100,000 women as opposed to the highest uncorrected rate of 15.6 cases per 100,000 aged 40 to 44 years. Correction for hysterectomy had the largest impact on older, black women given their high prevalence of hysterectomy. Correction for hysterectomy resulted in higher age-specific cervical cancer incidence rates, a shift in the peak incidence to older women, and an increase in the disparity in cervical cancer incidence between black and white women. Given the high and nondeclining rate of cervical cancer in women over the age of 60 to 65 years, when women are eligible to exit screening, risk and screening guidelines for cervical cancer in older women may need to be reconsidered. © 2014 American Cancer Society.

  20. Correcting for sequencing error in maximum likelihood phylogeny inference.

    PubMed

    Kuhner, Mary K; McGill, James

    2014-11-04

    Accurate phylogenies are critical to taxonomy as well as studies of speciation processes and other evolutionary patterns. Accurate branch lengths in phylogenies are critical for dating and rate measurements. Such accuracy may be jeopardized by unacknowledged sequencing error. We use simulated data to test a correction for DNA sequencing error in maximum likelihood phylogeny inference. Over a wide range of data polymorphism and true error rate, we found that correcting for sequencing error improves recovery of the branch lengths, even if the assumed error rate is up to twice the true error rate. Low error rates have little effect on recovery of the topology. When error is high, correction improves topological inference; however, when error is extremely high, using an assumed error rate greater than the true error rate leads to poor recovery of both topology and branch lengths. The error correction approach tested here was proposed in 2004 but has not been widely used, perhaps because researchers do not want to commit to an estimate of the error rate. This study shows that correction with an approximate error rate is generally preferable to ignoring the issue. Copyright © 2014 Kuhner and McGill.

  1. 77 FR 37421 - Reimbursement Rates for Calendar Year 2012 Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-21

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Indian Health Service Reimbursement Rates for Calendar Year 2012 Correction AGENCY: Indian Health Service, HHS. ACTION: Notice; correction. SUMMARY: The Indian Health Service published a document in the Federal Register on June 6, 2012, concerning rates for...

  2. Dual-mass vibratory rate gyroscope with suppressed translational acceleration response and quadrature-error correction capability

    NASA Technical Reports Server (NTRS)

    Clark, William A. (Inventor); Juneau, Thor N. (Inventor); Lemkin, Mark A. (Inventor); Roessig, Allen W. (Inventor)

    2001-01-01

    A microfabricated vibratory rate gyroscope to measure rotation includes two proof-masses mounted in a suspension system anchored to a substrate. The suspension has two principal modes of compliance, one of which is driven into oscillation. The driven oscillation combined with rotation of the substrate about an axis perpendicular to the substrate results in Coriolis acceleration along the other mode of compliance, the sense-mode. The sense-mode is designed to respond to Coriolis accelerationwhile suppressing the response to translational acceleration. This is accomplished using one or more rigid levers connecting the two proof-masses. The lever allows the proof-masses to move in opposite directions in response to Coriolis acceleration. The invention includes a means for canceling errors, termed quadrature error, due to imperfections in implementation of the sensor. Quadrature-error cancellation utilizes electrostatic forces to cancel out undesired sense-axis motion in phase with drive-mode position.

  3. Performance consequences of alternating directional control-response compatibility: evidence from a coal mine shuttle car simulator.

    PubMed

    Zupanc, Christine M; Burgess-Limerick, Robin J; Wallis, Guy

    2007-08-01

    To investigate error and reaction time consequences of alternating compatible and incompatible steering arrangements during a simulated obstacle avoidance task. Underground coal mine shuttle cars provide an example of a vehicle in which operators are required to alternate between compatible and incompatible steering configurations. This experiment examines the performance of 48 novice participants in a virtual analogy of an underground coal mine shuttle car. Participants were randomly assigned to a compatible condition, an incompatible condition, an alternating condition in which compatibility alternated within and between hands, or an alternating condition in which compatibility alternated between hands. Participants made fewer steering direction errors and made correct steering responses more quickly in the compatible condition. Error rate decreased over time in the incompatible condition. A compatibility effect for both errors and reaction time was also found when the control-response relationship alternated; however, performance improvements over time were not consistent. Isolating compatibility to a hand resulted in reduced error rate and faster reaction time than when compatibility alternated within and between hands. The consequences of alternating control-response relationships are higher error rates and slower responses, at least in the early stages of learning. This research highlights the importance of ensuring consistently compatible human-machine directional control-response relationships.

  4. An introduction to mixture item response theory models.

    PubMed

    De Ayala, R J; Santiago, S Y

    2017-02-01

    Mixture item response theory (IRT) allows one to address situations that involve a mixture of latent subpopulations that are qualitatively different but within which a measurement model based on a continuous latent variable holds. In this modeling framework, one can characterize students by both their location on a continuous latent variable as well as by their latent class membership. For example, in a study of risky youth behavior this approach would make it possible to estimate an individual's propensity to engage in risky youth behavior (i.e., on a continuous scale) and to use these estimates to identify youth who might be at the greatest risk given their class membership. Mixture IRT can be used with binary response data (e.g., true/false, agree/disagree, endorsement/not endorsement, correct/incorrect, presence/absence of a behavior), Likert response scales, partial correct scoring, nominal scales, or rating scales. In the following, we present mixture IRT modeling and two examples of its use. Data needed to reproduce analyses in this article are available as supplemental online materials at http://dx.doi.org/10.1016/j.jsp.2016.01.002. Copyright © 2016 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  5. HPA axis reactivity to pharmacologic and psychological stressors in euthymic women with histories of postpartum versus major depression.

    PubMed

    Ferguson, Elizabeth H; Di Florio, Arianna; Pearson, Brenda; Putnam, Karen T; Girdler, Susan; Rubinow, David R; Meltzer-Brody, Samantha

    2017-06-01

    It is unclear whether women with a history of postpartum depression (PPD) have residual, abnormal hypothalamic-pituitary-adrenal (HPA) axis reactivity, as has been reported in major depression (MDD). Further unclear is whether the abnormalities in HPA axis reactivity associated with MDD represent a stable, underlying predisposition or a state-dependent phenomenon. This study sought the following: (1) to determine if euthymic postpartum women with a history of depression have an abnormal HPA axis reactivity to pharmacologic and psychological challenges and (2) to compare HPA reactivity in women with histories of PPD versus MDD. As a secondary objective, we wanted to determine the influence of trauma history on HPA axis function. Forty-five parous (12-24 months postpartum), euthymic women with history of MDD (n = 15), PPD (n = 15), and controls (n = 15) completed pharmacologic (dexamethasone/corticotropin-releasing hormone (CRH) test [DEX/CRH]) and psychological (Trier social stress test [TSST]) challenges during the luteal phase. Outcome measures were cortisol and adrenocorticotropic hormone (ACTH) response after DEX/CRH, and blood pressure, heart rate, epinephrine, norepinephrine, and cortisol response during the TSST. All groups had robust cortisol and ACTH response to DEX/CRH and cortisol response to TSST. Groups did not differ significantly in cortisol or ACTH response to DEX/CRH or in blood pressure, heart rate, epinephrine, norepinephrine, or cortisol response to TSST. Cortisol/ACTH ratio did not differ significantly between groups. Trauma history was associated with decreased cortisol response to DEX/CRH in women with histories of MDD, which was not significant after correction (F 8,125 , p = 0.02, Greenhouse-Geisser corrected p = 0.11). Currently euthymic women with histories of MDD or PPD did not demonstrate residual abnormal stress responsivity following administration of either a pharmacologic or psychological stressor.

  6. Comparing spatially static and dynamic vibrotactile take-over requests in the driver seat.

    PubMed

    Petermeijer, S M; Cieler, S; de Winter, J C F

    2017-02-01

    Vibrotactile stimuli can be effective as warning signals, but their effectiveness as directional take-over requests in automated driving is yet unknown. This study aimed to investigate the correct response rate, reaction times, and eye and head orientation for static versus dynamic directional take-over requests presented via vibrating motors in the driver seat. In a driving simulator, eighteen participants performed three sessions: 1) a session involving no driving (Baseline), 2) driving a highly automated car without additional task (HAD), and 3) driving a highly automated car while performing a mentally demanding task (N-Back). Per session, participants received four directional static (in the left or right part of the seat) and four dynamic (moving from one side towards the opposite left or right of the seat) take-over requests via two 6×4 motor matrices embedded in the seat back and bottom. In the Baseline condition, participants reported whether the cue was left or right, and in the HAD and N-Back conditions participants had to change lanes to the left or to the right according to the directional cue. The correct response rate was operationalized as the accuracy of the self-reported direction (Baseline session) and the accuracy of the lane change direction (HAD & N-Back sessions). The results showed that the correct response rate ranged between 94% for static patterns in the Baseline session and 74% for dynamic patterns in the N-Back session, although these effects were not statistically significant. Steering wheel touch and steering input reaction times were approximately 200ms faster for static patterns than for dynamic ones. Eye tracking results revealed a correspondence between head/eye-gaze direction and lane change direction, and showed that head and eye-gaze movements where initiated faster for static vibrations than for dynamic ones. In conclusion, vibrotactile stimuli presented via the driver seat are effective as warnings, but their effectiveness as directional take-over requests may be limited. The present study may encourage further investigation into how to get drivers safely back into the loop. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Bronchopulmonary dysplasia: effect of altitude correction and role for the Neonatal Research Network Prediction Algorithm.

    PubMed

    Gulliver, Kristina; Yoder, Bradley A

    2018-05-09

    To determine the effect of altitude correction on bronchopulmonary dysplasia (BPD) rates and to assess validity of the NICHD "Neonatal BPD Outcome Estimator" for predicting BPD with and without altitude correction. Retrospective analysis included neonates born <30 weeks gestational age (GA) between 2010 and 2016. "Effective" FiO 2 requirements were determined at 36 weeks corrected GA. Altitude correction performed via ratio of barometric pressure (BP) in our unit to sea level BP. Probability of death and/or moderate-to-severe BPD was calculated using the NICHD BPD Outcome Estimator. Five hundred and sixty-one infants were included. Rate of moderate-to-severe BPD decreased from 71 to 40% following altitude correction. Receiver-operating characteristic curves indicated high predictability of BPD Outcome Estimator for altitude-corrected moderate-to-severe BPD diagnosis. Correction for altitude reduced moderate-to-severe BPD rate by almost 50%, to a rate consistent with recent published values. NICHD BPD Outcome Estimator is a valid tool for predicting the risk of moderate-to-severe BPD following altitude correction.

  8. Effects of pesticides and antibiotics on penaeid shrimp with special emphases on behavioral and biomarker responses.

    PubMed

    Tu, Huynh Thi; Silvestre, Frederic; Phuong, Nguyen Thanh; Kestemont, Patrick

    2010-04-01

    The purpose of the present study is to provide information on the current state of knowledge regarding the effects of pesticides and antibiotics used in aquaculture on penaeid shrimp, one of the most common aquatic products for human consumption, with a special emphasis on the use of behavioral, physiological, and biochemical response. These include behavior; feeding rate changes; respiration rate, oxygen consumption, and osmoregulation alterations; nucleic acids, protein, and glycogen synthesis; cholinesterase activity inhibition; ATPase activity; and oxidative stress responses. This paper also deals with residues of antibiotics and pesticides in penaeid shrimp. Antibiotics and pesticides used in aquaculture may have adverse effects on treated animals and human consumers health if they are not correctly used. As a complement to the measurement of antibiotic and pesticide residues in tissues, the use of behavioral and biomarker responses can provide more relevant biological information on the potential adverse effects of antibiotics and pesticides on penaeid shrimp health. (c) 2009 SETAC.

  9. The acquisition of conditioned responding.

    PubMed

    Harris, Justin A

    2011-04-01

    This report analyzes the acquisition of conditioned responses in rats trained in a magazine approach paradigm. Following the suggestion by Gallistel, Fairhurst, and Balsam (2004), Weibull functions were fitted to the trial-by-trial response rates of individual rats. These showed that the emergence of responding was often delayed, after which the response rate would increase relatively gradually across trials. The fit of the Weibull function to the behavioral data of each rat was equaled by that of a cumulative exponential function incorporating a response threshold. Thus, the growth in conditioning strength on each trial can be modeled by the derivative of the exponential--a difference term of the form used in many models of associative learning (e.g., Rescorla & Wagner, 1972). Further analyses, comparing the acquisition of responding with a continuously reinforced stimulus (CRf) and a partially reinforced stimulus (PRf), provided further evidence in support of the difference term. In conclusion, the results are consistent with conventional models that describe learning as the growth of associative strength, incremented on each trial by an error-correction process.

  10. The National Criminal Justice Treatment Practices survey: Multilevel survey methods and procedures⋆

    PubMed Central

    Taxman, Faye S.; Young, Douglas W.; Wiersema, Brian; Rhodes, Anne; Mitchell, Suzanne

    2007-01-01

    The National Criminal Justice Treatment Practices (NCJTP) survey provides a comprehensive inquiry into the nature of programs and services provided to adult and juvenile offenders involved in the justice system in the United States. The multilevel survey design covers topics such as the mission and goals of correctional and treatment programs; organizational climate and culture for providing services; organizational capacity and needs; opinions of administrators and staff regarding rehabilitation, punishment, and services provided to offenders; treatment policies and procedures; and working relationships between correctional and other agencies. The methodology generates national estimates of the availability of programs and services for offenders. This article details the methodology and sampling frame for the NCJTP survey, response rates, and survey procedures. Prevalence estimates of juvenile and adult offenders under correctional control are provided with externally validated comparisons to illustrate the veracity of the methodology. Limitations of the survey methods are also discussed. PMID:17383548

  11. Hypercorrection of high-confidence errors in the classroom.

    PubMed

    Carpenter, Shana K; Haynes, Cynthia L; Corral, Daniel; Yeung, Kam Leung

    2018-05-19

    People often have erroneous knowledge about the world that is firmly entrenched in memory and endorsed with high confidence. Although strong errors in memory would seem difficult to "un-learn," evidence suggests that errors are more likely to be corrected through feedback when they are originally endorsed with high confidence compared to low confidence. This hypercorrection effect has been predominantly studied in laboratory settings with general knowledge (i.e., trivia) questions, however, and has not been systematically explored in authentic classroom contexts. In the current study, college students in an introductory horticulture class answered questions about the course content, rated their confidence in their answers, received feedback of the correct answers, and then later completed a posttest. Results revealed a significant hypercorrection effect, along with a tendency for students with higher prior knowledge of the material to express higher confidence in, and in turn more effective correction of, their error responses.

  12. MELCOR Analysis of OSU Multi-Application Small Light Water Reactor (MASLWR) Experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoon, Dhongik S.; Jo, HangJin; Fu, Wen

    A multi-application small light water reactor (MASLWR) conceptual design was developed by Oregon State University (OSU) with emphasis on passive safety systems. The passive containment safety system employs condensation and natural circulation to achieve the necessary heat removal from the containment in case of postulated accidents. Containment condensation experiments at the MASLWR test facility at OSU are modeled and analyzed with MELCOR, a system-level reactor accident analysis computer code. The analysis assesses its ability to predict condensation heat transfer in the presence of noncondensable gas for accidents where high-energy steam is released into the containment. This work demonstrates MELCOR’s abilitymore » to predict the pressure-temperature response of the scaled containment. Our analysis indicates that the heat removal rates are underestimated in the experiment due to the limited locations of the thermocouples and applies corrections to these measurements by conducting integral energy analyses along with CFD simulation for confirmation. Furthermore, the corrected heat removal rate measurements and the MELCOR predictions on the heat removal rate from the containment show good agreement with the experimental data.« less

  13. MELCOR Analysis of OSU Multi-Application Small Light Water Reactor (MASLWR) Experiment

    DOE PAGES

    Yoon, Dhongik S.; Jo, HangJin; Fu, Wen; ...

    2017-05-23

    A multi-application small light water reactor (MASLWR) conceptual design was developed by Oregon State University (OSU) with emphasis on passive safety systems. The passive containment safety system employs condensation and natural circulation to achieve the necessary heat removal from the containment in case of postulated accidents. Containment condensation experiments at the MASLWR test facility at OSU are modeled and analyzed with MELCOR, a system-level reactor accident analysis computer code. The analysis assesses its ability to predict condensation heat transfer in the presence of noncondensable gas for accidents where high-energy steam is released into the containment. This work demonstrates MELCOR’s abilitymore » to predict the pressure-temperature response of the scaled containment. Our analysis indicates that the heat removal rates are underestimated in the experiment due to the limited locations of the thermocouples and applies corrections to these measurements by conducting integral energy analyses along with CFD simulation for confirmation. Furthermore, the corrected heat removal rate measurements and the MELCOR predictions on the heat removal rate from the containment show good agreement with the experimental data.« less

  14. Anxiety, inhibition, efficiency, and effectiveness. An investigation using antisaccade task.

    PubMed

    Derakshan, Nazanin; Ansari, Tahereh L; Hansard, Miles; Shoker, Leor; Eysenck, Michael W

    2009-01-01

    Effects of anxiety on the antisaccade task were assessed. Performance effectiveness on this task (indexed by error rate) reflects a conflict between volitional and reflexive responses resolved by inhibitory processes (Hutton, S. B., & Ettinger, U. (2006). The antisaccade task as a research tool in psychopathology: A critical review. Psychophysiology, 43, 302-313). However, latency of the first correct saccade reflects processing efficiency (relationship between performance effectiveness and use of resources). In two experiments, high-anxious participants had longer correct antisaccade latencies than low-anxious participants and this effect was greater with threatening cues than positive or neutral ones. The high- and low-anxious groups did not differ in terms of error rate in the antisaccade task. No group differences were found in terms of latency or error rate in the prosaccade task. These results indicate that anxiety affects performance efficiency but not performance effectiveness. The findings are interpreted within the context of attentional control theory (Eysenck, M. W., Derakshan, N., Santos, R., & Calvo, M. G. (2007). Anxiety and cognitive performance: Attentional control theory. Emotion, 7 (2), 336-353).

  15. Correcting haemoglobin cut-offs to define anaemia in high-altitude pregnant women in Peru reduces adverse perinatal outcomes.

    PubMed

    Gonzales, Gustavo F; Tapia, Vilma; Gasco, Manuel

    2014-07-01

    To determine if correction of cut-offs of haemoglobin levels to define anaemia at high altitudes affects rates of adverse perinatal outcomes. Data were obtained from 161,909 mothers and newborns whose births occurred between 1,000 and 4,500 m above sea level (masl). Anaemia was defined with or without correction of haemoglobin (Hb) for altitude as Hb <11 g/dL. Correction of haemoglobin per altitude was performed according to guidelines from the World Health Organization. Rates of stillbirths and preterm births were also calculated. Stillbirth and preterm rates were significantly reduced in cases of anaemia calculated after correction of haemoglobin for altitude compared to values obtained without Hb correction. At high altitudes (3,000-4,500 masl), after Hb correction, the rate of stillbirths was reduced from 37.7 to 18.3 per 1,000 live births (p < 0.01); similarly, preterm birth rates were reduced from 13.1 to 8.76 % (p < 0.01). The odds ratios for stillbirths and for preterm births were also reduced after haemoglobin correction. At high altitude, correction of maternal haemoglobin should not be performed to assess the risks for preterm birth and stillbirth. In fact, using low altitude Hb cut-off is associated with predicting those at risk.

  16. 77 FR 36563 - Indian Health Service; Reimbursement Rates for Calendar Year 2012 Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-19

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Indian Health Service; Reimbursement Rates for Calendar Year 2012 Correction AGENCY: Indian Health Service, HHS. ACTION: Notice; correction. SUMMARY: The Indian Health Service published a document in the Federal Register on June 6, 2012, concerning rates for...

  17. Deficiency in Mental Rotation of Upper and Lower-Limbs in Patients With Multiple Sclerosis and Its Relation With Cognitive Functions.

    PubMed

    Azin, Mahdieh; Zangiabadi, Nasser; Moghadas Tabrizi, Yousef; Iranmanesh, Farhad; Baneshi, Mohammad Reza

    2016-08-01

    Mental rotation is a cognitive motor process which was impaired in different neurologic disorders. We investigated whether there were deficits in response pattern, reaction time and response accuracy rate of mental rotation in multiple sclerosis (MS) patients compared to healthy subjects and whether cognitive dysfunctions in MS patients were correlated with mental rotation deficits. Moreover, we showed whether there was a difference between upper and lower-limbs mental rotation in MS patients. Thirty-five MS patients and 25 healthy subjects performed hand mental rotation (HMR) and foot mental rotation (FMR) tasks. Visual information processing speed, spatial learning and memory ability, and visuospatial processing were assessed by Symbol Digit Modalities Test (SDMT), Brief Visuospatial Memory Test-Revised (BVMT-R), and Judgment of Line Orientation Test (JLO) respectively in MS patients. Reaction time for both hand and foot stimuli increased, and response accuracy rate for hand stimuli decreased in MS patients compared to healthy subjects, but response pattern of mental rotation in MS patients persisted. Similar to healthy subjects, MS patients performed upper-limbs mental rotation more easily than a lower-limbs mental rotation with more speed and response accuracy rate. Reaction time and response accuracy rate were correlated with the mentioned cognitive functions. MS patients made use of the correct response pattern for problem solving of increasing orientation from upright stimuli. Reaction time and response accuracy rate altered in these patients and this alteration might occur along with impairment in motor planning. Subjects' better responding to hand stimuli was due to more familiarity with hand stimuli. The correlation of mental rotation ability with cognitive functions indicates the possible role of cognitive functions in mental rotation.

  18. Identification accuracy of children versus adults: a meta-analysis.

    PubMed

    Pozzulo, J D; Lindsay, R C

    1998-10-01

    Identification accuracy of children and adults was examined in a meta-analysis. Preschoolers (M = 4 years) were less likely than adults to make correct identifications. Children over the age of 5 did not differ significantly from adults with regard to correct identification rate. Children of all ages examined were less likely than adults to correctly reject a target-absent lineup. Even adolescents (M = 12-13 years) did not reach an adult rate of correct rejection. Compared to simultaneous lineup presentation, sequential lineups increased the child-adult gap for correct rejections. Providing child witnesses with identification practice or training did not increase their correct rejection rates. Suggestions for children's inability to correctly reject target-absent lineups are discussed. Future directions for identification research are presented.

  19. Dynamic Sensorimotor Planning during Long-Term Sequence Learning: The Role of Variability, Response Chunking and Planning Errors

    PubMed Central

    Verstynen, Timothy; Phillips, Jeff; Braun, Emily; Workman, Brett; Schunn, Christian; Schneider, Walter

    2012-01-01

    Many everyday skills are learned by binding otherwise independent actions into a unified sequence of responses across days or weeks of practice. Here we looked at how the dynamics of action planning and response binding change across such long timescales. Subjects (N = 23) were trained on a bimanual version of the serial reaction time task (32-item sequence) for two weeks (10 days total). Response times and accuracy both showed improvement with time, but appeared to be learned at different rates. Changes in response speed across training were associated with dynamic changes in response time variability, with faster learners expanding their variability during the early training days and then contracting response variability late in training. Using a novel measure of response chunking, we found that individual responses became temporally correlated across trials and asymptoted to set sizes of approximately 7 bound responses at the end of the first week of training. Finally, we used a state-space model of the response planning process to look at how predictive (i.e., response anticipation) and error-corrective (i.e., post-error slowing) processes correlated with learning rates for speed, accuracy and chunking. This analysis yielded non-monotonic association patterns between the state-space model parameters and learning rates, suggesting that different parts of the response planning process are relevant at different stages of long-term learning. These findings highlight the dynamic modulation of response speed, variability, accuracy and chunking as multiple movements become bound together into a larger set of responses during sequence learning. PMID:23056630

  20. Speed-constrained three-axes attitude control using kinematic steering

    NASA Astrophysics Data System (ADS)

    Schaub, Hanspeter; Piggott, Scott

    2018-06-01

    Spacecraft attitude control solutions typically are torque-level algorithms that simultaneously control both the attitude and angular velocity tracking errors. In contrast, robotic control solutions are kinematic steering commands where rates are treated as the control variable, and a servo-tracking control subsystem is present to achieve the desired control rates. In this paper kinematic attitude steering controls are developed where an outer control loop establishes a desired angular response history to a tracking error, and an inner control loop tracks the commanded body angular rates. The overall stability relies on the separation principle of the inner and outer control loops which must have sufficiently different response time scales. The benefit is that the outer steering law response can be readily shaped to a desired behavior, such as limiting the approach angular velocity when a large tracking error is corrected. A Modified Rodrigues Parameters implementation is presented that smoothly saturates the speed response. A robust nonlinear body rate servo loop is developed which includes integral feedback. This approach provides a convenient modular framework that makes it simple to interchange outer and inner control loops to readily setup new control implementations. Numerical simulations illustrate the expected performance for an aggressive reorientation maneuver subject to an unknown external torque.

  1. Telephone triage by nurses in primary care out-of-hours services in Norway: an evaluation study based on written case scenarios

    PubMed Central

    Hunskaar, Steinar

    2011-01-01

    Background The use of nurses for telephone-based triage in out-of-hours services is increasing in several countries. No investigations have been carried out in Norway into the quality of decisions made by nurses regarding our priority degree system. There are three levels: acute, urgent and non-urgent. Methods Nurses working in seven casualty clinics in out-of-hours districts in Norway (The Watchtowers) were all invited to participate in a study to assess priority grade on 20 written medical scenarios validated by an expert group. 83 nurses (response rate 76%) participated in the study. A one-out-of-five sample of the nurses assessed the same written cases after 3 months (n=18, response rate 90%) as a test–retest assessment. Results Among the acute, urgent and non-urgent scenarios, 82%, 74% and 81% were correctly classified according to national guidelines. There were significant differences in the proportion of correct classifications among the casualty clinics, but neither employment percentage nor profession or work experience affected the triage decision. The mean intraobserver variability measured by the Cohen kappa was 0.61 (CI 0.52 to 0.70), and there were significant differences in kappa with employment percentage. Casualty clinics and work experience did not affect intrarater agreement. Conclusion Correct classification of acute and non-urgent cases among nurses was quite high. Work experience and employment percentage did not affect triage decision. The intrarater agreement was good and about the same as in previous studies performed in other countries. Kappa increased significantly with increasing employment percentage. PMID:21262792

  2. Telephone triage by nurses in primary care out-of-hours services in Norway: an evaluation study based on written case scenarios.

    PubMed

    Hansen, Elisabeth Holm; Hunskaar, Steinar

    2011-05-01

    The use of nurses for telephone-based triage in out-of-hours services is increasing in several countries. No investigations have been carried out in Norway into the quality of decisions made by nurses regarding our priority degree system. There are three levels: acute, urgent and non-urgent. Nurses working in seven casualty clinics in out-of-hours districts in Norway (The Watchtowers) were all invited to participate in a study to assess priority grade on 20 written medical scenarios validated by an expert group. 83 nurses (response rate 76%) participated in the study. A one-out-of-five sample of the nurses assessed the same written cases after 3 months (n = 18, response rate 90%) as a test-retest assessment. Among the acute, urgent and non-urgent scenarios, 82%, 74% and 81% were correctly classified according to national guidelines. There were significant differences in the proportion of correct classifications among the casualty clinics, but neither employment percentage nor profession or work experience affected the triage decision. The mean intraobserver variability measured by the Cohen kappa was 0.61 (CI 0.52 to 0.70), and there were significant differences in kappa with employment percentage. Casualty clinics and work experience did not affect intrarater agreement. Correct classification of acute and non-urgent cases among nurses was quite high. Work experience and employment percentage did not affect triage decision. The intrarater agreement was good and about the same as in previous studies performed in other countries. Kappa increased significantly with increasing employment percentage.

  3. SU-E-T-460: Impact of the LINAC Repetition Rate On a High-Resolution Liquid Ionization Chamber Array for Patient-Specific QA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, S; Driewer, J; Zheng, D

    2015-06-15

    Purpose: The purpose of this study is to investigate the LINAC repetition-rate (dose-rate) dependence of OCTAVIUS 1000SRS liquid ionization chamber (LIC) array for patient specific QA of SRT plans delivered with flattening-filter-free (FFF) beams. Methods: 1) The repetition-rate dependence of 1000SRS was measured in a phantom constructed with 5-cm solid water above and below the array for build-up and backscatter. A 0.3cc calibrated ion chamber was also placed along the central axis 2.3cm below the center chamber of the array for normalizing LINAC output fluctuation. The signals from the center chamber of the array under different repetition rates in themore » range of 400–2400 MU/min for 6xFFF and 10xFFF beams on a Varian TrueBeamSTx LINAC, normalized by the independent chamber readings, were analyzed for the array response dependence on repetition rates. 2) Twelve Step-and-shoot IMRS QA plans (6xFFF and 10xFFF) were delivered to the array under different repetition rates for analysis and comparison. 3) The absolute doses measured by the center chamber were compared to measurements using an independent ionization chamber with the identical setup, taken as the gold standard. 4) The correction factors based on the actual delivery repetition rate were applied to the measurements, and the results were compared again to the gold standard. Results: 1) The 1000SRS array exhibited repetition-rate dependence for FFF beams, up to 5% for 6xFFF and 10% for 10xFFF; 2) The array showed clinically-acceptable repetition-rate dependence for regular flattened beams; 3) This repetition-rate dependence significantly affected the measurement accuracy, thereby affecting IMRS QA results; 4) By applying an empirical repetition-rate correction, the corrected measurements agreed better with the gold standard ion chamber measurements. Conclusion: OCTAVIUS 1000SRS LIC array exhibited considerable repetition-rate dependence for FFF beams, which will affect the accuracy of the absolute QA measurements, especially for IMRS plans with the step-and-shoot technique.« less

  4. The relationship between change in subjective outcome and change in disease: a potential paradox.

    PubMed

    Kievit, Wietske; Hendrikx, Jos; Stalmeier, Peep F M; van de Laar, Mart A F J; Van Riel, Piet L C M; Adang, Eddy M

    2010-09-01

    Response shift theory suggests that improvements in health lead patients to change their internal standards and re-assess former health states as worse than initially rated when using retrospective ratings via the then-test. The predictions of response shift theory can be illustrated using prospect theory, whereby a change in current health causes a change in reference frame. Therefore, if health deteriorates, the former health state will receive a better rating, whereas if it improves, the former health state will receive a worse rating. To explore the predictions of response shift and prospect theory by relating subjective change to objective change. Baseline and 3-month follow-up data from a cohort of rheumatoid arthritis patients (N = 197) starting on TNFalpha-blocking agents were used. Objective disease change was classified according to a disease-specific clinical outcome measure (DAS28). Visual analogue scales (VAS) for general health (GH) and pain were used as self-reported measures. Three months after starting on anti-TNFalpha, patients used the then-test to re-rate their baseline health with regard to general health and pain. Differences between then-test value and baseline values were calculated and tested between improved, non-improved and deteriorated patients by the Student t-test. At 3 months, 51 (25.9%) patients had good improvement in health, 83 (42.1%) had moderate improvement, and 63 (32.0%) had no improvement or deteriorated in health. All patients no matter whether they improved, did not improve, or even became worse rated their health as worse retrospectively. The difference between the then-test rating and the baseline value was similarly sized in all groups. More positive ratings of retrospective health are independent of disease change. This suggests that patients do not necessarily change their standards in line with their disease change, and therefore it is inappropriate to use the then-test to correct for such a change. If a then-test is used to correct for shifts in internal standards, it might lead to the paradoxical result that patients who do not improve or even deteriorate increase significantly on self-reported health and pain. An alternative explanation for differences in retrospective and prospective ratings of health is the implicit theory of change which is more successful in explaining our results than prospect theory.

  5. Evaluation of Kojima-Matsubara color vision test plates: validity in young children.

    PubMed

    Lee, D Y; Cotter, S A; French, A L

    1997-09-01

    We examined a pseudoisochromatic color plate test by Kojima and Matsubara for young children which uses drawings of familiar objects rather than letters or numbers. First, we evaluated the test's efficacy as a color deficiency screener and its validity in classifying the types of color deficiencies by comparing its results with those from the Moreland anomaloscope. Second, we eliminated the chromatic factor and evaluated the functional ability of young children to perform the task by determining how many correct responses were obtained using modified black/white replicas of the test plates. Part 1: Twenty color-normal and 13 color-deficient adults were diagnosed and classified with the Ishihara test, Panel D-15 test, and anomaloscope. Subjects were then tested with the Kojima-Matsubara test and result were compared with those from the anomaloscope. Part 2: Fifty children aged 3 to 7 years were tested with modified black/white test plate replicas. The number of correct responses for each plate was determined for five different age groups. Part 1: Among the 20 color-normal subjects, 18 read all 10 plates correctly and 2 subjects missed 1 of the 10. Only 1 of the 13 color-deficient subjects exhibited the expected responses for plates 2 to 6 (used for color deficiency screening). The color-deficient subjects' responses for plates 7 to 10, which are used to classify red-green defects, were varied and only the protanomalous subjects (n = 2) followed the expected response pattern. Part 2: Of the 10 black/white modified plates, only 2 were correctly identified by all 50 children. The other plates had a recognition rate that ranged from 32 to 98%. Because the response patterns given by most of the color-deficient adult subjects were different from those in the test manual, ambiguous results would occur if the Kojima-Matsubara test were used for color vision screening or the diagnosis of color deficiency. In addition, the difficulty that many of the young children exhibited in identifying the objects in the black/white replica plates suggests that there would be a large number of false positive errors (classifying a color normal as color deficient) when using this test in young children.

  6. Partners in immunization: 2010 survey examining differences among H1N1 vaccine providers in Washington state.

    PubMed

    Seib, Katherine; Gleason, Cindy; Richards, Jennifer L; Chamberlain, Allison; Andrews, Tracey; Watson, Lin; Whitney, Ellen; Hinman, Alan R; Omer, Saad B

    2013-01-01

    Emergency response involving mass vaccination requires the involvement of traditional vaccine providers as well as other health-care providers, including pharmacists, obstetricians, and health-care providers at correctional facilities. We explored differences in provider experiences administering pandemic vaccine during a public health emergency. We conducted a cross-sectional survey of H1N1 vaccine providers in Washington State, examining topics regarding pandemic vaccine administration, participation in preparedness activities, and communication with public health agencies. We also examined differences among provider types in responses received (n=619, 80.9% response rate). Compared with other types of vaccine providers (e.g., family practitioners, obstetricians, and specialists), pharmacists reported higher patient volumes as well as higher patient-to-practitioner ratios, indicating a broad capacity for community reach. Pharmacists and correctional health-care providers reported lower staff coverage with seasonal and H1N1 vaccines. Compared with other vaccine providers, pharmacists were also more likely to report relying on public health information from federal sources. They were less likely to report relying on local health departments (LHDs) for pandemic-related information, but indicated a desire to be included in LHD communications and plans. While all provider types indicated a high willingness to respond to a public health emergency, pharmacists were less likely to have participated in training, actual emergency response, or surge capacity initiatives. No obstetricians reported participating in surge capacity initiatives. Results from this survey suggest that efforts to increase communication and interaction between public health agencies and pharmacy, obstetric, and correctional health-care vaccine providers may improve future preparedness and emergency response capability and reach.

  7. Partners in Immunization: 2010 Survey Examining Differences Among H1N1 Vaccine Providers in Washington State

    PubMed Central

    Gleason, Cindy; Richards, Jennifer L.; Chamberlain, Allison; Andrews, Tracey; Watson, Lin; Whitney, Ellen; Hinman, Alan R.; Omer, Saad B.

    2013-01-01

    Objectives Emergency response involving mass vaccination requires the involvement of traditional vaccine providers as well as other health-care providers, including pharmacists, obstetricians, and health-care providers at correctional facilities. We explored differences in provider experiences administering pandemic vaccine during a public health emergency. Methods We conducted a cross-sectional survey of H1N1 vaccine providers in Washington State, examining topics regarding pandemic vaccine administration, participation in preparedness activities, and communication with public health agencies. We also examined differences among provider types in responses received (n=619, 80.9% response rate). Results Compared with other types of vaccine providers (e.g., family practitioners, obstetricians, and specialists), pharmacists reported higher patient volumes as well as higher patient-to-practitioner ratios, indicating a broad capacity for community reach. Pharmacists and correctional health-care providers reported lower staff coverage with seasonal and H1N1 vaccines. Compared with other vaccine providers, pharmacists were also more likely to report relying on public health information from federal sources. They were less likely to report relying on local health departments (LHDs) for pandemic-related information, but indicated a desire to be included in LHD communications and plans. While all provider types indicated a high willingness to respond to a public health emergency, pharmacists were less likely to have participated in training, actual emergency response, or surge capacity initiatives. No obstetricians reported participating in surge capacity initiatives. Conclusions Results from this survey suggest that efforts to increase communication and interaction between public health agencies and pharmacy, obstetric, and correctional health-care vaccine providers may improve future preparedness and emergency response capability and reach. PMID:23633735

  8. The Detection and Correction of Bias in Student Ratings of Instruction.

    ERIC Educational Resources Information Center

    Haladyna, Thomas; Hess, Robert K.

    1994-01-01

    A Rasch model was used to detect and correct bias in Likert rating scales used to assess student perceptions of college teaching, using a database of ratings. Statistical corrections were significant, supporting the model's potential utility. Recommendations are made for a theoretical rationale and further research on the model. (Author/MSE)

  9. Probability assessment with response times and confidence in perception and knowledge.

    PubMed

    Petrusic, William M; Baranski, Joseph V

    2009-02-01

    In both a perceptual and a general knowledge comparison task, participants categorized the time they took to decide, selecting one of six categories ordered from "Slow" to Fast". Subsequently, they rated confidence on a six-category scale ranging from "50%" to "100%". Participants were able to accurately scale their response times thus enabling the treatment of the response time (RT) categories as potential confidence categories. Probability assessment analyses of RTs revealed indices of over/underconfidence, calibration, and resolution, each subject to the "hard-easy" effect, comparable to those obtained with the actual confidence ratings. However, in both the perceptual and knowledge domains, resolution (i.e., the ability to use the confidence categories to distinguish correct from incorrect decisions) was significantly better with confidence ratings than with RT categorization. Generally, comparable results were obtained with scaling of the objective RTs, although subjective categorization of RTs provided probability assessment indices superior to those obtained from objective RTs. Taken together, the findings do not support the view that confidence arises from a scaling of decision time.

  10. U.S. Dietary and Physical Activity Guideline Knowledge and Corresponding Behaviors among 4th and 5th Grade Students: A Multi-Site Pilot Study

    ERIC Educational Resources Information Center

    Bea, Jennifer W.; Martinez, Stephanie; Armstrong-Florian, Traci; Farrell, Vanessa; Martinez, Cathy; Whitmer, Evelyn; Hartz, Vern; Blake, Samuel; Nicolini, Ariana; Misner, Scottie

    2014-01-01

    Knowledge of U.S. dietary and physical activity recommendations and corresponding behaviors were surveyed among 4th and 5th graders in five Arizona counties to determine the need for related education in SNAP-Ed eligible schools. A <70% target response rate was the criterion. Participants correctly identified recommendations for: fruit, 20%;…

  11. Impact of task-related changes in heart rate on estimation of hemodynamic response and model fit.

    PubMed

    Hillenbrand, Sarah F; Ivry, Richard B; Schlerf, John E

    2016-05-15

    The blood oxygen level dependent (BOLD) signal, as measured using functional magnetic resonance imaging (fMRI), is widely used as a proxy for changes in neural activity in the brain. Physiological variables such as heart rate (HR) and respiratory variation (RV) affect the BOLD signal in a way that may interfere with the estimation and detection of true task-related neural activity. This interference is of particular concern when these variables themselves show task-related modulations. We first establish that a simple movement task reliably induces a change in HR but not RV. In group data, the effect of HR on the BOLD response was larger and more widespread throughout the brain than were the effects of RV or phase regressors. The inclusion of HR regressors, but not RV or phase regressors, had a small but reliable effect on the estimated hemodynamic response function (HRF) in M1 and the cerebellum. We next asked whether the inclusion of a nested set of physiological regressors combining phase, RV, and HR significantly improved the model fit in individual participants' data sets. There was a significant improvement from HR correction in M1 for the greatest number of participants, followed by RV and phase correction. These improvements were more modest in the cerebellum. These results indicate that accounting for task-related modulation of physiological variables can improve the detection and estimation of true neural effects of interest. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ultra short-term heart rate recovery after maximal exercise: relations to aerobic power in sportsmen.

    PubMed

    Ostojic, Sergej M; Stojanovic, Marko D; Calleja-Gonzalez, Julio

    2011-04-30

    The main aim of the study was to investigate whether different levels of aerobic power influence heart rate (HR) responses during the first minute of recovery following maximal exercise in athletes. Thirty-two young male soccer players were recruited for the study during the final week of their training prior to [corrected] the competition. Following the maximal exercise on treadmill the participants were placed supine for 60 s of HR recording. The time between exercise cessation and the recovery HR measurement was kept as short as possible. At the end of exercise (i.e., the start of recovery), HRs were [corrected] was similar in both trials. At both 10 s and 20 s of recovery period, the players characterized by high aerobic power (> 60 ml/kg/ min) revealed significantly lower HR as compared to their sub-elite counterparts (< 50 ml/kg/min; P < 0.05). No differences between the groups were found at later stages of the analyzed post-exercise HR. The data suggest that the athletes characterized by high aerobic capacity could be better adapted to maximal exercise with faster recovery HR immediately following an exercise test. These results generally suggest that the aerobic power along with autonomic modulation might have played a role in the ultra short-term cardiovascular responses to all-out exercise.

  13. Correctional Officers and Workplace Adversity: Identifying Interpersonal, Cognitive, and Behavioral Response Tendencies.

    PubMed

    Trounson, Justin S; Pfeifer, Jeffrey E

    2017-10-01

    This study explored correctional officers' response tendencies (i.e., cognitive, interpersonal, and behavioral response patterns they engage in) when managing workplace adversity. In total, 53 Australian correctional officers participated in the study. Eight exploratory focus group discussions ( n = 42) were conducted to identify a set of officer-endorsed response tendencies. Thematic analysis of group data revealed that correctional officers engage in a range of response tendencies when facing workplace adversity and that these tendencies may be categorized as interpersonally, cognitively, or behaviorally based. Semistructured interviews ( n = 11) were then conducted to provide further depth of information regarding officer response tendency usage. Results are discussed in terms of common themes, future research, and implications for developing training programs designed to ameliorate the effects of workplace adversity.

  14. Dose rate effect of pulsed electron beam on micronucleus frequency in human peripheral blood lymphocytes.

    PubMed

    Acharya, Santhosh; Sanjeev, Ganesh; Bhat, Nagesh N; Narayana, Yerol

    2010-03-01

    The micronucleus assay in human peripheral blood lymphocytes is a sensitive indicator of radiation damage and could serve as a biological dosimeter in evaluating suspected overexposure to ionising radiation. Micronucleus (MN) frequency as a measure of chromosomal damage has also extensively been employed to quantify the effects of radiation dose rate on biological systems. Here we studied the effects of 8 MeV pulsed electron beam emitted by Microtron electron accelerator on MN induction at dose rates between 35 Gy min-1 and 352.5 Gy min-1. These dose rates were achieved by varying the pulse repetition rate (PRR). Fricke dosimeter was employed to measure the absorbed dose at different PRR and to ensure uniform dose distribution of the electron beam. To study the dose rate effect, blood samples were irradiated to an absorbed dose of (4.7+/-0.2) Gy at different rates and cytogenetic damage was quantified using the micronucleus assay. The obtained MN frequency showed no dose rate dependence within the studied dose rate range. Our earlier dose effect study using 8 MeV electrons revealed that the response of MN was linear-quadratic. Therefore, in the event of an accident, dose estimation can be made using linear-quadratic dose response parameters, without adding dose rate as a correction factor.

  15. Preclinical QT safety assessment: cross-species comparisons and human translation from an industry consortium.

    PubMed

    Holzgrefe, Henry; Ferber, Georg; Champeroux, Pascal; Gill, Michael; Honda, Masaki; Greiter-Wilke, Andrea; Baird, Theodore; Meyer, Olivier; Saulnier, Muriel

    2014-01-01

    In vivo models have been required to demonstrate relative cardiac safety, but model sensitivity has not been systematically investigated. Cross-species and human translation of repolarization delay, assessed as QT/QTc prolongation, has not been compared employing common methodologies across multiple species and sites. Therefore, the accurate translation of repolarization results within and between preclinical species, and to man, remains problematic. Six pharmaceutical companies entered into an informal consortium designed to collect high-resolution telemetered data in multiple species (dog; n=34, cynomolgus; n=37, minipig; n=12, marmoset; n=14, guinea pig; n=5, and man; n=57). All animals received vehicle and varying doses of moxifloxacin (3-100 mg/kg, p.o.) with telemetered ECGs (≥500 Hz) obtained for 20-24h post-dose. Individual probabilistic QT-RR relationships were derived for each subject. The rate-correction efficacies of the individual (QTca) and generic correction formulae (Bazett, Fridericia, and Van de Water) were objectively assessed as the mean squared slopes of the QTc-RR relationships. Normalized moxifloxacin QTca responses (Veh Δ%/μM) were derived for 1h centered on the moxifloxacin Tmax. All QT-RR ranges demonstrated probabilistic uncertainty; slopes varied distinctly by species where dog and human exhibited the lowest QT rate-dependence, which was much steeper in the cynomolgus and guinea pig. Incorporating probabilistic uncertainty, the normalized QTca-moxifloxacin responses were similarly conserved across all species, including man. The current results provide the first unambiguous evidence that all preclinical in vivo repolarization assays, when accurately modeled and evaluated, yield results that are consistent with the conservation of moxifloxacin-induced QT prolongation across all common preclinical species. Furthermore, these outcomes are directly transferable across all species including man. The consortium results indicate that the implementation of standardized QTc data presentation, QTc reference cycle lengths, and rate-correction coefficients can markedly improve the concordance of preclinical and clinical outcomes in most preclinical species. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. Functional Brain Connectome and Its Relation to Hoehn and Yahr Stage in Parkinson Disease.

    PubMed

    Suo, Xueling; Lei, Du; Li, Nannan; Cheng, Lan; Chen, Fuqin; Wang, Meiyun; Kemp, Graham J; Peng, Rong; Gong, Qiyong

    2017-12-01

    Purpose To use resting-state functional magnetic resonance (MR) imaging and graph theory approaches to investigate the brain functional connectome and its potential relation to disease severity in Parkinson disease (PD). Materials and Methods This case-control study was approved by the local research ethics committee, and all participants provided informed consent. There were 153 right-handed patients with PD and 81 healthy control participants recruited who were matched for age, sex, and handedness to undergo a 3-T resting-state functional MR examination. The whole-brain functional connectome was constructed by thresholding the Pearson correlation matrices of 90 brain regions, and the topologic properties were analyzed by using graph theory approaches. Nonparametric permutation tests were used to compare topologic properties, and their relationship to disease severity was assessed. Results The functional connectome in PD showed abnormalities at the global level (ie, decrease in clustering coefficient, global efficiency, and local efficiency, and increase in characteristic path length) and at the nodal level (decreased nodal centralities in the sensorimotor cortex, default mode, and temporal-occipital regions; P < .001, false discovery rate corrected). Further, the nodal centralities in left postcentral gyrus and left superior temporal gyrus correlated negatively with Unified Parkinson's Disease Rating Scale III score (P = .038, false discovery rate corrected, r = -0.198; and P = .009, false discovery rate corrected, r = -0.270, respectively) and decreased with increasing Hoehn and Yahr stage in patients with PD. Conclusion The configurations of brain functional connectome in patients with PD were perturbed and correlated with disease severity, notably with those responsible for motor functions. These results provide topologic insights into understanding the neural functional changes in relation to disease severity of PD. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on September 11, 2017.

  17. Position Corrections for Airspeed and Flow Angle Measurements on Fixed-Wing Aircraft

    NASA Technical Reports Server (NTRS)

    Grauer, Jared A.

    2017-01-01

    This report addresses position corrections made to airspeed and aerodynamic flow angle measurements on fixed-wing aircraft. These corrections remove the effects of angular rates, which contribute to the measurements when the sensors are installed away from the aircraft center of mass. Simplified corrections, which are routinely used in practice and assume small flow angles and angular rates, are reviewed. The exact, nonlinear corrections are then derived. The simplified corrections are sufficient in most situations; however, accuracy diminishes for smaller aircraft that incur higher angular rates, and for flight at high air flow angles. This is demonstrated using both flight test data and a nonlinear flight dynamics simulation of a subscale transport aircraft in a variety of low-speed, subsonic flight conditions.

  18. 76 FR 50726 - Integrated System Power Rates: Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-16

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Integrated System Power Rates: Correction AGENCY: Southwestern Power Administration, DOE. ACTION: Notice of public review and comment; Correction. SUMMARY: Southwestern Power Administration published a document in the Federal Register (76 FR 48159) on...

  19. Cortisol Levels in Relation to Maternal Interaction and Child Internalizing Behavior in Preterm and Full-Term Children at 18 Months Corrected Age

    PubMed Central

    Brummelte, Susanne; Grunau, Ruth E.; Zaidman-Zait, Anat; Weinberg, Joanne; Nordstokke, David; Cepeda, Ivan L.

    2011-01-01

    Cortisol levels were compared in children born preterm at extremely low gestational age (ELGA; 24–28 weeks), very low gestational age (VLGA; 29–32 weeks), and full-term in response to cognitive assessment at 18 months corrected age (CA). Further, we investigated the relationship between maternal interactive behaviors and child internalizing behaviors (rated by the mother) in relation to child cortisol levels. ELGA children had higher “pretest” cortisol levels and a different pattern of cortisol response to cognitive assessment compared to VLGA and full-terms. Higher cortisol levels in ELGA, but not full-term, children were associated with less optimal mother interactive behavior. Moreover, the pattern of cortisol change was related to internalizing behaviors among ELGA, and to a lesser degree VLGA children. In conclusion, our findings suggest altered programming of the hypothalamic-pituitary-adrenal (HPA) axis in preterm children, as well as their greater sensitivity to environmental context such as maternal interactive behavior. PMID:21298633

  20. A Comparison of Answer until Correct Feedback and Knowledge of Correct Response Feedback under Two Conditions of Contextualization.

    ERIC Educational Resources Information Center

    Clariana, Roy B.

    1990-01-01

    Discussion of various types of feedback used in computer-assisted instruction focuses on a study of low-ability eleventh graders that compared the effectiveness of answer until correct (AUC) feedback with knowledge of correct response (KCR) feedback. Achievement data on posttests as well as time data are analyzed. (11 references) (LRW)

  1. Corrective response times in a coordinated eye-head-arm countermanding task.

    PubMed

    Tao, Gordon; Khan, Aarlenne Z; Blohm, Gunnar

    2018-06-01

    Inhibition of motor responses has been described as a race between two competing decision processes of motor initiation and inhibition, which manifest as the reaction time (RT) and the stop signal reaction time (SSRT); in the case where motor initiation wins out over inhibition, an erroneous movement occurs that usually needs to be corrected, leading to corrective response times (CRTs). Here we used a combined eye-head-arm movement countermanding task to investigate the mechanisms governing multiple effector coordination and the timing of corrective responses. We found a high degree of correlation between effector response times for RT, SSRT, and CRT, suggesting that decision processes are strongly dependent across effectors. To gain further insight into the mechanisms underlying CRTs, we tested multiple models to describe the distribution of RTs, SSRTs, and CRTs. The best-ranked model (according to 3 information criteria) extends the LATER race model governing RTs and SSRTs, whereby a second motor initiation process triggers the corrective response (CRT) only after the inhibition process completes in an expedited fashion. Our model suggests that the neural processing underpinning a failed decision has a residual effect on subsequent actions. NEW & NOTEWORTHY Failure to inhibit erroneous movements typically results in corrective movements. For coordinated eye-head-hand movements we show that corrective movements are only initiated after the erroneous movement cancellation signal has reached a decision threshold in an accelerated fashion.

  2. [Techniques for pixel response nonuniformity correction of CCD in interferential imaging spectrometer].

    PubMed

    Yao, Tao; Yin, Shi-Min; Xiangli, Bin; Lü, Qun-Bo

    2010-06-01

    Based on in-depth analysis of the relative radiation scaling theorem and acquired scaling data of pixel response nonuniformity correction of CCD (charge-coupled device) in spaceborne visible interferential imaging spectrometer, a pixel response nonuniformity correction method of CCD adapted to visible and infrared interferential imaging spectrometer system was studied out, and it availably resolved the engineering technical problem of nonuniformity correction in detector arrays for interferential imaging spectrometer system. The quantitative impact of CCD nonuniformity on interferogram correction and recovery spectrum accuracy was given simultaneously. Furthermore, an improved method with calibration and nonuniformity correction done after the instrument is successfully assembled was proposed. The method can save time and manpower. It can correct nonuniformity caused by other reasons in spectrometer system besides CCD itself's nonuniformity, can acquire recalibration data when working environment is changed, and can also more effectively improve the nonuniformity calibration accuracy of interferential imaging

  3. The Impact of Respondent Burden on Current Drinker Rates.

    PubMed

    Callinan, Sarah

    2017-09-19

    Increasing response burden in alcohol surveys combined with filter questions to exclude abstainers, results in systematically missing data in questions on alcohol consumption as abstainers are not required to answer them. The aim of the current study is to assess the impact of responder burden on current drinker rates in a large scale Australian survey. 23,855 Australian adults completed the National Drug Strategy Household Survey in 2013 and answered increasingly complex questions on alcohol consumption. Although 80% of respondents stated that they had consumed alcohol in the past 12 months, the current drinker rate appears to be 78% excluding, or 74% including missing data if taken from the quantity frequency measure. When respondents are then asked to give more detailed responses in a graduated frequency measure, current drinker rates appear to be at 75% or 73%, excluding or including missing data. The rate of abstention in alcohol survey research is artificially inflated when more complex survey methods are used. Excluding missing data only partially corrects for this. Given that more sensitive analyses are usually performed on more detailed survey questions, rates of abstention and consumption should be adjusted to account for systematically missing data.

  4. Coastal uplift west of Algiers (Algeria): pre- and post-Messinian sequences of marine terraces and rasas and their associated drainage pattern

    NASA Astrophysics Data System (ADS)

    Authemayou, Christine; Pedoja, Kevin; Heddar, Aicha; Molliex, Stéphane; Boudiaf, Azzedine; Ghaleb, Bassam; Van Vliet Lanoe, Brigitte; Delcaillau, Bernard; Djellit, Hamou; Yelles, Karim; Nexer, Maelle

    2017-01-01

    The North Africa passive margin is affected by the ongoing convergence between the African and Eurasian plates. This convergence is responsible for coastal uplift, folding, and reverse faulting on new and reactivated faults on the margin. The active deformation is diffuse and thus rather difficult to locate precisely. We aim to determine how a coastal landscape evolve in this geodynamic setting and gain insights into active tectonics. More particularly, we evidence and quantify coastal uplift pattern of the Chenoua, Sahel, and Algiers reliefs (Algeria), using sequences of marine terraces and rasas and computing several morphometric indices from the drainage pattern. Upper and Middle Pleistocene uplift rates are obtained by fossil shoreline mapping and preliminary U/Th dating of associated coastal deposits. Extrapolation of these rates combined to analyses of sea-level referential data and spatial relationships between marine terraces/rasas and other geological markers lead us to tentatively propose an age for the highest coastal indicators (purported the oldest). Values of morphometric indices showing correlations with uplift rate allow us to analyze uplift variation on area devoid of coastal sequence. Geological and geomorphological data suggest that coastal uplift probably occurred since the Middle Miocene. It resulted in the emergence of the Algiers massif, followed by the Sahel ridge massif. The Sahel ridge has asymmetrically grown by folding from west to east and was affected by temporal variation of uplift. Compared to previous study, the location of the Sahel fold axis has been shifted offshore, near the coast. The Chenoua fault vertical motion does not offset significantly the coastal sequence. Mean apparent uplift rates and corrected uplift rates since 120 ka are globally steady all along the coast with a mean value of 0.055 ± 0.015 mm/year (apparent) and of 0.005 ± 0.045 mm/year (corrected for eustasy). Mean apparent coastal uplift rates between 120 and 400 ka increase eastward from 0.045 ± 0.025 to 0.19 ± 0.12 mm/year (without correction for eustasy) or from 0.06 ± 0.06 to 0.2 ± 0.15 mm/year (with correction for eustasy). In addition, the combination of structural and geomorphic data suggests a low uplift rate for the southern part of the Algiers massif.

  5. Nonuniformity correction algorithm with efficient pixel offset estimation for infrared focal plane arrays.

    PubMed

    Orżanowski, Tomasz

    2016-01-01

    This paper presents an infrared focal plane array (IRFPA) response nonuniformity correction (NUC) algorithm which is easy to implement by hardware. The proposed NUC algorithm is based on the linear correction scheme with the useful method of pixel offset correction coefficients update. The new approach to IRFPA response nonuniformity correction consists in the use of pixel response change determined at the actual operating conditions in relation to the reference ones by means of shutter to compensate a pixel offset temporal drift. Moreover, it permits to remove any optics shading effect in the output image as well. To show efficiency of the proposed NUC algorithm some test results for microbolometer IRFPA are presented.

  6. 32 CFR 724.902 - Propriety of the discharge.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... been corrected by the organization with primary responsibility for correcting the record. (c) The primary function of the NDRB is to exercise its discretion on issues of equity by reviewing the individual... which the primary responsibility for corrective action rests with another organization (for example...

  7. 32 CFR 724.902 - Propriety of the discharge.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... been corrected by the organization with primary responsibility for correcting the record. (c) The primary function of the NDRB is to exercise its discretion on issues of equity by reviewing the individual... which the primary responsibility for corrective action rests with another organization (for example...

  8. 32 CFR 724.902 - Propriety of the discharge.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... been corrected by the organization with primary responsibility for correcting the record. (c) The primary function of the NDRB is to exercise its discretion on issues of equity by reviewing the individual... which the primary responsibility for corrective action rests with another organization (for example...

  9. 32 CFR 724.902 - Propriety of the discharge.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... been corrected by the organization with primary responsibility for correcting the record. (c) The primary function of the NDRB is to exercise its discretion on issues of equity by reviewing the individual... which the primary responsibility for corrective action rests with another organization (for example...

  10. 32 CFR 724.902 - Propriety of the discharge.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... been corrected by the organization with primary responsibility for correcting the record. (c) The primary function of the NDRB is to exercise its discretion on issues of equity by reviewing the individual... which the primary responsibility for corrective action rests with another organization (for example...

  11. Survey of nutrition knowledge of physicians in Kuwait.

    PubMed

    Allafi, Ahmad R; Alajmi, Fahhad; Al-Haifi, Ahmad

    2013-07-01

    The objective of the present study was to determine whether nutrition knowledge differs between male and female physicians working in Kuwait City, Kuwait. The study employed a cross-sectional analysis of physician’s nutrition knowledge by using a sixteen-item multiple-choice questionnaire. Governmental hospitals in Kuwait City, Kuwait. One hundred Kuwaiti physicians (fifty males; fifty females) working in Kuwait City, Kuwait. A response rate of 73% was achieved (forty males; thirty-three females). The mean percentage of correctly answered questions was 60 %. The male and female physicians averaged 56% and 65% of correct responses, respectively (P50?042). However, only for two questions did male and female physicians’ scores differ significantly (P,0?05). The two age groups (,40 years; $40 years) had equal mean total correct scores (60 %, P50?935). Physicians’ knowledge was greatest for topics that have received a great deal of media coverage in Kuwait. Most (70 %) of the physicians described their nutrition knowledge as ‘moderate’. Physicians in Kuwait gave inaccurate information regarding common problems in Kuwaitis such as obesity, hypertension and osteoporosis. In view of the public’s perception of the role of the physician in providing nutrition advice, it is imperative that nutrition and diet training be part of continuing medical education to bridge these deficiencies in physicians’ knowledge.

  12. Effects of dynamic long-period ocean tides on changes in earth's rotation rate

    NASA Technical Reports Server (NTRS)

    Nam, Young; Dickman, S. R.

    1990-01-01

    As a generalization of the zonal response coefficient first introduced by Agnew and Farrell (1978), the zonal response function kappa of the solid earth-ocean system is defined as the ratio, in the frequency domain, of the tidal change in earth's rotation rate to the tide-generating potential. Amplitudes and phases of kappa for the monthly, fortnightly, and nine-day lunar tides are estimated from 2 1/2 years of VLBI UT1 observations, corrected for atmospheric angular momentum effects using NMC wind and pressure series. Using the dynamic ocean tide model of Dickman (1988, 1989), amplitudes and phases of kappa for an elastic earth-ocean system are predicted. The predictions confirm earlier results which found that dynamic effects of the longer-period ocean tides reduce the amplitude of kappa by about 1 percent.

  13. Effect of Peer Instruction on the Likelihood for Choosing the Correct Response to a Physiology Question

    ERIC Educational Resources Information Center

    Relling, Alejandro E.; Giuliodori, Mauricio J.

    2015-01-01

    The aims of the present study were to measure the effects of individual answer (correct vs. incorrect), individual answer of group members (no vs. some vs. all correct), self-confidence about the responses (low vs. mid vs. high), sex (female vs. male students), and group size (2-4 students) on the odds for change and for correctness after peer…

  14. Perceptibility curve test for digital radiographs before and after correction for attenuation and correction for attenuation and visual response.

    PubMed

    Li, G; Welander, U; Yoshiura, K; Shi, X-Q; McDavid, W D

    2003-11-01

    Two digital image processing methods, correction for X-ray attenuation and correction for attenuation and visual response, have been developed. The aim of the present study was to compare digital radiographs before and after correction for attenuation and correction for attenuation and visual response by means of a perceptibility curve test. Radiographs were exposed of an aluminium test object containing holes ranging from 0.03 mm to 0.30 mm with increments of 0.03 mm. Fourteen radiographs were exposed with the Dixi system (Planmeca Oy, Helsinki, Finland) and twelve radiographs were exposed with the F1 iOX system (Fimet Oy, Monninkylä, Finland) from low to high exposures covering the full exposure ranges of the systems. Radiographs obtained from the Dixi and F1 iOX systems were 12 bit and 8 bit images, respectively. Original radiographs were then processed for correction for attenuation and correction for attenuation and visual response. Thus, two series of radiographs were created. Ten viewers evaluated all the radiographs in the same random order under the same viewing conditions. The object detail having the lowest perceptible contrast was recorded for each observer. Perceptibility curves were plotted according to the mean of observer data. The perceptibility curves for processed radiographs obtained with the F1 iOX system are higher than those for originals in the exposure range up to the peak, where the curves are basically the same. For radiographs exposed with the Dixi system, perceptibility curves for processed radiographs are higher than those for originals for all exposures. Perceptibility curves show that for 8 bit radiographs obtained from the F1 iOX system, the contrast threshold was increased in processed radiographs up to the peak, while for 12 bit radiographs obtained with the Dixi system, the contrast threshold was increased in processed radiographs for all exposures. When comparisons were made between radiographs corrected for attenuation and corrected for attenuation and visual response, basically no differences were found. Radiographs processed for correction for attenuation and correction for attenuation and visual response may improve perception, especially for 12 bit originals.

  15. Sex knowledge and attitudes of moderately retarded males.

    PubMed

    Edmonson, B; Wish, J

    1975-09-01

    In semistructured interview sessions, 18 moderately retarded men undergoing deinstitutional training, were questioned to determine their understanding of pictures of homosexual embrace, masturbation, dating, marriage, intercourse, pregnancy, childbirth, drunkenness, and their knowledge of anatomical terminology. The frequencies of various response categories revealed a range of comprehension, the lowest answering only 10 percent correctly, the median consisting of 28 percent correct, and only 1 subject correctly answering as many as one-half of the items. Correct conceptual responses significantly correlated with WAIS Full Scale and Verbal IQs and were also significantly related to the Adaptive Behavior Scale domains of Language, Socialization, and Responsibility. Serious errors of fact and conceptual confusion, though most prevalent in responses by the low comprehenders, were found in at least some responses by all of the men.

  16. Frequency analysis of heart rate variability: a useful assessment tool of linearly polarized near-infrared irradiation to stellate ganglion area for burning mouth syndrome.

    PubMed

    Momota, Yukihiro; Takano, Hideyuki; Kani, Koichi; Matsumoto, Fumihiro; Motegi, Katsumi; Aota, Keiko; Yamamura, Yoshiko; Omori, Mayuko; Tomioka, Shigemasa; Azuma, Masayuki

    2013-03-01

    Burning mouth syndrome (BMS) is characterized by the following subjective complaints without distinct organic changes: burning sensation in mouth or chronic pain of tongue. BMS is also known as glossodynia; both terms are used equivalently in Japan. Although the real cause of BMS is still unknown, it has been pointed out that BMS is related to some autonomic abnormality, and that stellate ganglion near-infrared irradiation (SGR) corrects the autonomic abnormality. Frequency analysis of heart rate variability (HRV) is expected to be useful for assessing autonomic abnormality. This study investigated whether frequency analysis of HRV could reveal autonomic abnormality associated with BMS, and whether autonomic changes were corrected after SGR. Eight subjects received SGR; the response to SGR was assessed by frequency analysis of HRV. No significant difference of autonomic activity concerning low-frequency (LF) norm, high-frequency (HF) norm, and low-frequency/high-frequency (LF/HF) was found between SGR effective and ineffective groups. Therefore, we proposed new parameters: differential normalized low frequency (D LF norm), differential normalized high frequency (D HF norm), and differential low-frequency/high-frequency (D LF/HF), which were defined as differentials between original parameters just before and after SGR. These parameters as indexes of responsiveness of autonomic nervous system (ANS) revealed autonomic changes in BMS, and BMS seems to be related to autonomic instability rather than autonomic imbalance. Frequency analysis of HRV revealed the autonomic instability associated with BMS and enabled tracing of autonomic changes corrected with SGR. It is suggested that frequency analysis of HRV is very useful in follow up of BMS and for determination of the therapeutic efficacy of SGR. Wiley Periodicals, Inc.

  17. Properties of a commercial PTW-60019 synthetic diamond detector for the dosimetry of small radiotherapy beams.

    PubMed

    Lárraga-Gutiérrez, José Manuel; Ballesteros-Zebadúa, Paola; Rodríguez-Ponce, Miguel; García-Garduño, Olivia Amanda; de la Cruz, Olga Olinca Galván

    2015-01-21

    A CVD based radiation detector has recently become commercially available from the manufacturer PTW-Freiburg (Germany). This detector has a sensitive volume of 0.004 mm(3), a nominal sensitivity of 1 nC Gy(-1) and operates at 0 V. Unlike natural diamond based detectors, the CVD diamond detector reports a low dose rate dependence. The dosimetric properties investigated in this work were dose rate, angular dependence and detector sensitivity and linearity. Also, percentage depth dose, off-axis dose profiles and total scatter ratios were measured and compared against equivalent measurements performed with a stereotactic diode. A Monte Carlo simulation was carried out to estimate the CVD small beam correction factors for a 6 MV photon beam. The small beam correction factors were compared with those obtained from stereotactic diode and ionization chambers in the same irradiation conditions The experimental measurements were performed in 6 and 15 MV photon beams with the following square field sizes: 10 × 10, 5 × 5, 4 × 4, 3 × 3, 2 × 2, 1.5 × 1.5, 1 × 1 and 0.5 × 0.5 cm. The CVD detector showed an excellent signal stability (<0.2%) and linearity, negligible dose rate dependence (<0.2%) and lower response angular dependence. The percentage depth dose and off-axis dose profiles measurements were comparable (within 1%) to the measurements performed with ionization chamber and diode in both conventional and small radiotherapy beams. For the 0.5 × 0.5 cm, the measurements performed with the CVD detector showed a partial volume effect for all the dosimetric quantities measured. The Monte Carlo simulation showed that the small beam correction factors were close to unity (within 1.0%) for field sizes ≥1 cm. The synthetic diamond detector had high linearity, low angular and negligible dose rate dependence, and its response was energy independent within 1% for field sizes from 1.0 to 5.0 cm. This work provides new data showing the performance of the CVD detector compared against a high spatial resolution diode. It also presents a comparison of the CVD small beam correction factors with those of diode and ionization chamber for a 6 MV photon beam.

  18. Colonoscopy screening for colorectal cancer: the outcomes of two recruitment methods.

    PubMed

    Corbett, Mike; Chambers, Sharon L; Shadbolt, Bruce; Hillman, Lybus C; Taupin, Doug

    2004-10-18

    To determine the response to colorectal cancer (CRC) screening by colonoscopy, through direct invitation or through invitation by general practitioners. Two-way comparison of randomised population sampling versus cluster sampling of a representative general practice population in the Australian Capital Territory, May 2002 to January 2004. Invitation to screen, assessment for eligibility, interview, and colonoscopy. 881 subjects aged 55-74 years were invited to screen: 520 from the electoral roll (ER) sample and 361 from the general practice (GP) cluster sample. Response rate, participation rate, and rate of adenomatous polyps in the screened group. Participation was similar in the ER arm (35.1%; 95% CI, 30.2%-40.3%) and the GP arm (40.1%; 95% CI, 29.2%-51.0%) after correcting for ineligibility, which was higher in the ER arm. Superior eligibility in the GP arm was offset by the labour of manual record review. Response rates after two invitations were similar for the two groups (ER arm: 78.8%; 95% CI, 75.1%-82.1%; GP arm: 81.7%; 95% CI, 73.8%-89.6%). Overall, 53.4% ineligibility arose from having a colonoscopy in the past 10 years (ER arm, 98/178; GP arm, 42/84). Of 231 colonoscopies performed, 229 were complete, with 32% of subjects screened having adenomatous polyps. Colonoscopy-based CRC screening yields similar response and participation rates with either random population sampling or general practice cluster sampling, with population sampling through the electoral roll providing greater ease of recruitment.

  19. Signal Detection and Frame Synchronization of Multiple Wireless Networking Waveforms

    DTIC Science & Technology

    2007-09-01

    punctured to obtain coding rates of 2 3 and 3 4 . Convolutional forward error correction coding is used to detect and correct bit...likely to be isolated and be correctable by the convolutional decoder. 44 Data rate (Mbps) Modulation Coding Rate Coded bits per subcarrier...binary convolutional code . A shortened Reed-Solomon technique is employed first. The code is shortened depending upon the data

  20. Do Individuals Perceive Income Tax Rates Correctly?

    PubMed

    Gideon, Michael

    2017-01-01

    This article uses data from survey questions fielded on the 2011 wave of the Cognitive Economics Study to uncover systematic errors in perceptions of income tax rates. First, when asked about the marginal tax rates (MTRs) for households in the top tax bracket, respondents underestimate the top MTR on wages and salary income, overestimate the MTR on dividend income, and therefore significantly underestimate the currently tax-advantaged status of dividend income. Second, when analyzing the relationship between respondents' self-reported average tax rates (ATRs) and MTRs, many people do not understand the progressive nature of the federal income tax system. Third, when comparing self-reported tax rates with those computed from self-reported income, respondents systematically overestimate their ATR while reported MTR are accurate at the mean, the responses are consistent with underestimation of tax schedule progressivity.

  1. Do Individuals Perceive Income Tax Rates Correctly?

    PubMed Central

    Gideon, Michael

    2017-01-01

    This article uses data from survey questions fielded on the 2011 wave of the Cognitive Economics Study to uncover systematic errors in perceptions of income tax rates. First, when asked about the marginal tax rates (MTRs) for households in the top tax bracket, respondents underestimate the top MTR on wages and salary income, overestimate the MTR on dividend income, and therefore significantly underestimate the currently tax-advantaged status of dividend income. Second, when analyzing the relationship between respondents' self-reported average tax rates (ATRs) and MTRs, many people do not understand the progressive nature of the federal income tax system. Third, when comparing self-reported tax rates with those computed from self-reported income, respondents systematically overestimate their ATR while reported MTR are accurate at the mean, the responses are consistent with underestimation of tax schedule progressivity. PMID:29238156

  2. Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

    NASA Astrophysics Data System (ADS)

    Lockhart, M.; Henzlova, D.; Croft, S.; Cutler, T.; Favalli, A.; McGahee, Ch.; Parker, R.

    2018-01-01

    Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli(DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. The current paper discusses and presents the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. In order to assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. The DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

  3. Age-related change in fast adaptation mechanisms measured with the scotopic full-field ERG.

    PubMed

    Tillman, Megan A; Panorgias, Athanasios; Werner, John S

    2016-06-01

    To quantify the response dynamics of fast adaptation mechanisms of the scotopic ERG in younger and older adults using full-field m-sequence flash stimulation. Scotopic ERGs were measured for a series of flashes separated by 65 ms over a range of 260 ms in 16 younger (20-26, 22.2 ± 2.1; range mean ±1 SD) and 16 older (65-85, 71.2 ± 7) observers without retinal pathology. A short-wavelength (λ peak = 442 nm) LED was used for scotopic stimulation, and the flashes ranged from 0.0001 to 0.01 cd s m(-2). The complete binary kernel series was derived from the responses to the m-sequence flash stimulation, and the first- and second-order kernel responses were analyzed. The first-order kernel represented the response to a single, isolated flash, while the second-order kernels reflected the adapted flash responses that followed a single flash by one or more base intervals. B-wave amplitudes of the adapted flash responses were measured and plotted as a function of interstimulus interval to describe the recovery of the scotopic ERG. A linear function was fitted to the linear portion of the recovery curve, and the slope of the line was used to estimate the rate of fast adaptation recovery. The amplitudes of the isolated flash responses and rates of scotopic fast adaptation recovery were compared between the younger and older participants using a two-way ANOVA. The isolated flash responses and rates of recovery were found to be significantly lower in the older adults. However, there was no difference between the two age groups in response amplitude or recovery rate after correcting for age-related changes in the density of the ocular media. These results demonstrated that the rate of scotopic fast adaptation recovery of normal younger and older adults is similar when stimuli are equated for retinal illuminance.

  4. Differences in autonomic physiological responses between good and poor inductive reasoners.

    PubMed

    Melis, C; van Boxtel, A

    2001-11-01

    We investigated individual- and task-related differences in autonomic physiological responses induced by time limited figural and verbal inductive reasoning tasks. In a group of 52 participants, the percentage of correctly responded task items was evaluated together with nine different autonomic physiological response measures and respiration rate (RR). Weighted multidimensional scaling analyses of the physiological responses revealed three underlying dimensions, primarily characterized by RR, parasympathetic, and sympathetic activity. RR and sympathetic activity appeared to be relatively more important response dimensions for poor reasoners, whereas parasympathetic responsivity was relatively more important for good reasoners. These results suggest that poor reasoners showed higher levels of cognitive processing intensity than good reasoners. Furthermore, for the good reasoners, the dimension of sympathetic activity was relatively more important during the figural than during the verbal reasoning task, which was explained in terms of hemispheric lateralization in autonomic function.

  5. Respiratory sinus arrhythmia responses to cognitive tasks: effects of task factors and RSA indices.

    PubMed

    Overbeek, Thérèse J M; van Boxtel, Anton; Westerink, Joyce H D M

    2014-05-01

    Many studies show that respiratory sinus arrhythmia (RSA) decreases while performing cognitive tasks. However, there is uncertainty about the role of contaminating factors such as physical activity and stress-inducing task variables. Different methods to quantify RSA may also contribute to variable results. In 83 healthy subjects, we studied RSA responses to a working memory task requiring varying levels of cognitive control and a perceptual attention task not requiring strong cognitive control. RSA responses were quantified in the time and frequency domain and were additionally corrected for differences in mean interbeat interval and respiration rate, resulting in eight different RSA indices. The two tasks were clearly differentiated by heart rate and facial EMG reference measures. Cognitive control induced inhibition of RSA whereas perceptual attention generally did not. However, the results show several differences between different RSA indices, emphasizing the importance of methodological variables. Age and sex did not influence the results. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Reconstruction of disease transmission rates: Applications to measles, dengue, and influenza.

    PubMed

    Lange, Alexander

    2016-07-07

    Transmission rates are key in understanding the spread of infectious diseases. Using the framework of compartmental models, we introduce a simple method to reconstruct time series of transmission rates directly from incidence or disease-related mortality data. The reconstruction employs differential equations, which model the time evolution of infective stages and strains. Being sensitive to initial values, the method produces asymptotically correct solutions. The computations are fast, with time complexity being quadratic. We apply the reconstruction to data of measles (England and Wales, 1948-1967), dengue (Thailand, 1982-1999), and influenza (U.S., 1910-1927). The Measles example offers comparison with earlier work. Here we re-investigate reporting corrections, include and exclude demographic information. The dengue example deals with the failure of vector-control measures in reducing dengue hemorrhagic fever (DHF) in Thailand. Two competing mechanisms have been held responsible: strain interaction and demographic transitions. Our reconstruction reveals that both explanations are possible, showing that the increase in DHF cases is consistent with decreasing transmission rates resulting from reduced vector counts. The flu example focuses on the 1918/1919 pandemic, examining the transmission rate evolution for an invading strain. Our analysis indicates that the pandemic strain could have circulated in the population for many months before the pandemic was initiated by an event of highly increased transmission. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Abnormal heart rate recovery and deficient chronotropic response after submaximal exercise in young Marfan syndrome patients.

    PubMed

    Peres, Paulo; Carvalho, Antônio C; Perez, Ana Beatriz A; Medeiros, Wladimir M

    2016-10-01

    Marfan syndrome patients present important cardiac structural changes, ventricular dysfunction, and electrocardiographic changes. An abnormal heart rate response during or after exercise is an independent predictor of mortality and autonomic dysfunction. The aim of the present study was to compare heart rate recovery and chronotropic response obtained by cardiac reserve in patients with Marfan syndrome subjected to submaximal exercise. A total of 12 patients on β-blocker therapy and 13 off β-blocker therapy were compared with 12 healthy controls. They were subjected to submaximal exercise with lactate measurements. The heart rate recovery was obtained in the first minute of recovery and corrected for cardiac reserve and peak lactate concentration. Peak heart rate (141±16 versus 155±17 versus 174±8 bpm; p=0.001), heart rate reserve (58.7±9.4 versus 67.6±14.3 versus 82.6±4.8 bpm; p=0.001), heart rate recovery (22±6 versus 22±8 versus 34±9 bpm; p=0.001), and heart rate recovery/lactate (3±1 versus 3±1 versus 5±1 bpm/mmol/L; p=0.003) were different between Marfan groups and controls, respectively. All the patients with Marfan syndrome had heart rate recovery values below the mean observed in the control group. The absolute values of heart rate recovery were strongly correlated with the heart rate reserve (r=0.76; p=0.001). Marfan syndrome patients have reduced heart rate recovery and chronotropic deficit after submaximal exercise, and the chronotropic deficit is a strong determinant of heart rate recovery. These changes are suggestive of autonomic dysfunction.

  8. Present-day uplift of the western Alps.

    PubMed

    Nocquet, J-M; Sue, C; Walpersdorf, A; Tran, T; Lenôtre, N; Vernant, P; Cushing, M; Jouanne, F; Masson, F; Baize, S; Chéry, J; van der Beek, P A

    2016-06-27

    Collisional mountain belts grow as a consequence of continental plate convergence and eventually disappear under the combined effects of gravitational collapse and erosion. Using a decade of GPS data, we show that the western Alps are currently characterized by zero horizontal velocity boundary conditions, offering the opportunity to investigate orogen evolution at the time of cessation of plate convergence. We find no significant horizontal motion within the belt, but GPS and levelling measurements independently show a regional pattern of uplift reaching ~2.5 mm/yr in the northwestern Alps. Unless a low viscosity crustal root under the northwestern Alps locally enhances the vertical response to surface unloading, the summed effects of isostatic responses to erosion and glaciation explain at most 60% of the observed uplift rates. Rock-uplift rates corrected from transient glacial isostatic adjustment contributions likely exceed erosion rates in the northwestern Alps. In the absence of active convergence, the observed surface uplift must result from deep-seated processes.

  9. Confident failures: Lapses of working memory reveal a metacognitive blind spot.

    PubMed

    Adam, Kirsten C S; Vogel, Edward K

    2017-07-01

    Working memory performance fluctuates dramatically from trial to trial. On many trials, performance is no better than chance. Here, we assessed participants' awareness of working memory failures. We used a whole-report visual working memory task to quantify both trial-by-trial performance and trial-by-trial subjective ratings of inattention to the task. In Experiment 1 (N = 41), participants were probed for task-unrelated thoughts immediately following 20% of trials. In Experiment 2 (N = 30), participants gave a rating of their attentional state following 25% of trials. Finally, in Experiments 3a (N = 44) and 3b (N = 34), participants reported confidence of every response using a simple mouse-click judgment. Attention-state ratings and off-task thoughts predicted the number of items correctly identified on each trial, replicating previous findings that subjective measures of attention state predict working memory performance. However, participants correctly identified failures on only around 28% of failure trials. Across experiments, participants' metacognitive judgments reliably predicted variation in working memory performance but consistently and severely underestimated the extent of failures. Further, individual differences in metacognitive accuracy correlated with overall working memory performance, suggesting that metacognitive monitoring may be key to working memory success.

  10. Measuring Investment in Learning: Can Electrocardiogram Provide an Indication of Cognitive Effort During Learning?

    PubMed

    Patterson, Jae T; Hart, Amanda; Hansen, Steve; Carter, Michael J; Ditor, David

    2016-04-01

    Heart rate variability (i.e., low frequency:high frequency ratio) was measured to differentiate invested cognitive effort during the acquisition and retention of a novel task. Participants (12 male, M = 25.1 year, SD = 3.6; 12 female, M = 22.8 year, SD = 1.1) were required to produce Braille equivalents of English letter primes on a standardized keyboard in proactive or retroactive conditions (groups, each n = 12). The correct Braille response was either provided before (i.e., proactively) or after (i.e., retroactively) the participant's response. During acquisition, participants in the proactive group demonstrated shorter study time, greater recall success, and reported lower cognitive investment. Participants in the proactive and retroactive groups did not statistically differ in heart rate variability. For retention, the retroactive group showed greater recall success, lower perceived cognitive effort investment, and lower heart rate variability. The results highlight the usefulness of heart rate variability in discriminating the cognitive effort invested for a recently acquired skill. © The Author(s) 2016.

  11. 32 CFR 70.9 - Discharge review standards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... to the extent that the error has been corrected by the organization with primary responsibility for correcting the record. (3) The primary function of the DRB is to exercise its discretion on issues of equity... of issuance involves a matter in which the primary responsibility for corrective action rests with...

  12. 32 CFR 70.9 - Discharge review standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... to the extent that the error has been corrected by the organization with primary responsibility for correcting the record. (3) The primary function of the DRB is to exercise its discretion on issues of equity... of issuance involves a matter in which the primary responsibility for corrective action rests with...

  13. 32 CFR 70.9 - Discharge review standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... to the extent that the error has been corrected by the organization with primary responsibility for correcting the record. (3) The primary function of the DRB is to exercise its discretion on issues of equity... of issuance involves a matter in which the primary responsibility for corrective action rests with...

  14. 78 FR 67951 - Price Cap Rules for Certain Postal Rate Adjustments; Corrections

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-13

    ... POSTAL REGULATORY COMMISSION 39 CFR Part 3010 [Docket No. RM2013-2; Order No. 1786] Price Cap Rules for Certain Postal Rate Adjustments; Corrections AGENCY: Postal Regulatory Commission. ACTION: Correcting amendments. SUMMARY: The Postal Regulatory Commission published a document in the Federal Register...

  15. Dynamic performance of MEMS deformable mirrors for use in an active/adaptive two-photon microscope

    NASA Astrophysics Data System (ADS)

    Zhang, Christian C.; Foster, Warren B.; Downey, Ryan D.; Arrasmith, Christopher L.; Dickensheets, David L.

    2016-03-01

    Active optics can facilitate two-photon microscopic imaging deep in tissue. We are investigating fast focus control mirrors used in concert with an aberration correction mirror to control the axial position of focus and system aberrations dynamically during scanning. With an adaptive training step, sample-induced aberrations may be compensated as well. If sufficiently fast and precise, active optics may be able to compensate under-corrected imaging optics as well as sample aberrations to maintain diffraction-limited performance throughout the field of view. Toward this end we have measured a Boston Micromachines Corporation Multi-DM 140 element deformable mirror, and a Revibro Optics electrostatic 4-zone focus control mirror to characterize dynamic performance. Tests for the Multi-DM included both step response and sinusoidal frequency sweeps of specific Zernike modes. For the step response we measured 10%-90% rise times for the target Zernike amplitude, and wavefront rms error settling times. Frequency sweeps identified the 3dB bandwidth of the mirror when attempting to follow a sinusoidal amplitude trajectory for a specific Zernike mode. For five tested Zernike modes (defocus, spherical aberration, coma, astigmatism and trefoil) we find error settling times for mode amplitudes up to 400nm to be less than 52 us, and 3 dB frequencies range from 6.5 kHz to 10 kHz. The Revibro Optics mirror was tested for step response only, with error settling time of 80 μs for a large 3 um defocus step, and settling time of only 18 μs for a 400nm spherical aberration step. These response speeds are sufficient for intra-scan correction at scan rates typical of two-photon microscopy.

  16. Solution for the nonuniformity correction of infrared focal plane arrays.

    PubMed

    Zhou, Huixin; Liu, Shangqian; Lai, Rui; Wang, Dabao; Cheng, Yubao

    2005-05-20

    Based on the S-curve model of the detector response of infrared focal plan arrays (IRFPAs), an improved two-point correction algorithm is presented. The algorithm first transforms the nonlinear image data into linear data and then uses the normal two-point algorithm to correct the linear data. The algorithm can effectively overcome the influence of nonlinearity of the detector's response, and it enlarges the correction precision and the dynamic range of the response. A real-time imaging-signal-processing system for IRFPAs that is based on a digital signal processor and field-programmable gate arrays is also presented. The nonuniformity correction capability of the presented solution is validated by experimental imaging procedures of a 128 x 128 pixel IRFPA camera prototype.

  17. Variable effects of prevalence correction of population denominators on differentials in myocardial infarction incidence: a record linkage study in Aboriginal and non-Aboriginal Western Australians.

    PubMed

    Katzenellenbogen, Judith M; Sanfilippo, Frank M; Hobbs, Michael S T; Briffa, Tom G; Ridout, Steve C; Knuiman, Matthew W; Dimer, Lyn; Taylor, Kate P; Thompson, Peter L; Thompson, Sandra C

    2011-06-01

    To investigate the impact of prevalence correction of population denominators on myocardial infarction (MI) incidence rates, rate ratios, and rate differences in Aboriginal vs. non-Aboriginal Western Australians aged 25-74 years during the study period 2000-2004. Person-based linked hospital and mortality data sets were used to estimate the number of prevalent and first-ever MI cases each year from 2000 to 2004 using a 15-year look-back period. Age-specific and -standardized MI incidence rates were calculated using both prevalence-corrected and -uncorrected population denominators, by sex and Aboriginality. The impact of prevalence correction on rates increased with age, was higher for men than women, and substantially greater for Aboriginal than non-Aboriginal people. Despite the systematic underestimation of incidence, prevalence correction had little impact on the Aboriginal to non-Aboriginal age-standardized rate ratios (6% and 4% underestimate in men and women, respectively), although the impact on rate differences was more marked (12% and 6%, respectively). The percentage underestimate of differentials was greater at older ages. Prevalence correction of denominators, while more accurate, is difficult to apply and may add modestly to the quantification of relative disparities in MI incidence between populations. Absolute incidence disparities using uncorrected denominators may have an error >10%. Copyright © 2011 Elsevier Inc. All rights reserved.

  18. Correcting reaction rates measured by saturation-transfer magnetic resonance spectroscopy

    NASA Astrophysics Data System (ADS)

    Gabr, Refaat E.; Weiss, Robert G.; Bottomley, Paul A.

    2008-04-01

    Off-resonance or spillover irradiation and incomplete saturation can introduce significant errors in the estimates of chemical rate constants measured by saturation-transfer magnetic resonance spectroscopy (MRS). Existing methods of correction are effective only over a limited parameter range. Here, a general approach of numerically solving the Bloch-McConnell equations to calculate exchange rates, relaxation times and concentrations for the saturation-transfer experiment is investigated, but found to require more measurements and higher signal-to-noise ratios than in vivo studies can practically afford. As an alternative, correction formulae for the reaction rate are provided which account for the expected parameter ranges and limited measurements available in vivo. The correction term is a quadratic function of experimental measurements. In computer simulations, the new formulae showed negligible bias and reduced the maximum error in the rate constants by about 3-fold compared to traditional formulae, and the error scatter by about 4-fold, over a wide range of parameters for conventional saturation transfer employing progressive saturation, and for the four-angle saturation-transfer method applied to the creatine kinase (CK) reaction in the human heart at 1.5 T. In normal in vivo spectra affected by spillover, the correction increases the mean calculated forward CK reaction rate by 6-16% over traditional and prior correction formulae.

  19. Autonomic nervous system function, child behavior, and maternal sensitivity in three-year-old children with surgically corrected transposition.

    PubMed

    Harrison, Tondi M

    2013-01-01

    Explore relationships among autonomic nervous system (ANS) function, child behavior, and maternal sensitivity in three-year-old children with surgically corrected transposition of the great arteries (TGA) and in children healthy at birth. Children surviving complex congenital heart defects are at risk for behavior problems. ANS function is associated with behavior and with maternal sensitivity. Child ANS function (heart rate variability) and maternal sensitivity (Parent-Child Early Relational Assessment) were measured during a challenging task. Mother completed the Child Behavior Checklist. Data were analyzed descriptively and graphically. Children with TGA had less responsive autonomic function and more behavior problems than healthy children. Autonomic function improved with more maternal sensitivity. Alterations in ANS function may continue years after surgical correction in children with TGA, potentially impacting behavioral regulation. Maternal sensitivity may be associated with ANS function in this population. Continued research on relationships among ANS function, child behavior, and maternal sensitivity is warranted. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Modeling motivated misreports to sensitive survey questions.

    PubMed

    Böckenholt, Ulf

    2014-07-01

    Asking sensitive or personal questions in surveys or experimental studies can both lower response rates and increase item non-response and misreports. Although non-response is easily diagnosed, misreports are not. However, misreports cannot be ignored because they give rise to systematic bias. The purpose of this paper is to present a modeling approach that identifies misreports and corrects for them. Misreports are conceptualized as a motivated process under which respondents edit their answers before they report them. For example, systematic bias introduced by overreports of socially desirable behaviors or underreports of less socially desirable ones can be modeled, leading to more-valid inferences. The proposed approach is applied to a large-scale experimental study and shows that respondents who feel powerful tend to overclaim their knowledge.

  1. A standard methodology for the analysis, recording, and control of verbal behavior

    PubMed Central

    Drash, Philip W.; Tudor, Roger M.

    1991-01-01

    Lack of a standard methodology has been one of the major obstacles preventing advancement of behavior analytic research in verbal behavior. This article presents a standard method for the analysis, recording, and control of verbal behavior that overcomes several major methodological problems that have hindered operant research in verbal behavior. The system divides all verbal behavior into four functional response classes, correct, error, no response, and inappropriate behavior, from which all vocal responses of a subject may be classified and consequated. The effects of contingencies of reinforcement on verbal operants within each category are made immediately visible to the researcher as changes in frequency of response. Incorporating frequency of response within each category as the unit of response allows both rate and probability of verbal response to be utilized as basic dependent variables. This method makes it possible to record and consequate verbal behavior in essentially the same way as any other operant response. It may also facilitate an experimental investigation of Skinner's verbal response categories. PMID:22477629

  2. Long-Term Study of Heart Rate Variability Responses to Changes in the Solar and Geomagnetic Environment.

    PubMed

    Alabdulgader, Abdullah; McCraty, Rollin; Atkinson, Michael; Dobyns, York; Vainoras, Alfonsas; Ragulskis, Minvydas; Stolc, Viktor

    2018-02-08

    This long-term study examined relationships between solar and magnetic factors and the time course and lags of autonomic nervous system (ANS) responses to changes in solar and geomagnetic activity. Heart rate variability (HRV) was recorded for 72 consecutive hours each week over a five-month period in 16 participants in order to examine ANS responses during normal background environmental periods. HRV measures were correlated with solar and geomagnetic variables using multivariate linear regression analysis with Bonferroni corrections for multiple comparisons after removing circadian influences from both datasets. Overall, the study confirms that daily ANS activity responds to changes in geomagnetic and solar activity during periods of normal undisturbed activity and it is initiated at different times after the changes in the various environmental factors and persist over varying time periods. Increase in solar wind intensity was correlated with increases in heart rate, which we interpret as a biological stress response. Increase in cosmic rays, solar radio flux, and Schumann resonance power was all associated with increased HRV and parasympathetic activity. The findings support the hypothesis that energetic environmental phenomena affect psychophysical processes that can affect people in different ways depending on their sensitivity, health status and capacity for self-regulation.

  3. Eye movements as a function of response contingencies measured by blackout technique1

    PubMed Central

    Doran, Judith; Holland, James G.

    1971-01-01

    A program may have a low error rate but, at the same time, require little of the student and teach him little. A measure to supplement error rate in evaluating a program has recently been developed. This measure, called the blackout ratio, is the percentage of material that may be deleted without increasing the error rate. In high blackout-ratio programs, obtaining a correct answer is contingent upon only a small portion of the item. The present study determined if such low response-contingent material is read less thoroughly than programmed material that is heavily response-contingent. Eye movements were compared for two versions of the same program that differed only in the choice of the omitted words. The alteration of the required responses resulted in a version with a higher blackout ratio than the original version, which had a low blackout ratio. Eighteen undergraduates received half their material from the high and half their material from the low blackout-ratio version. The order was counterbalanced. Location and duration of all eye fixations in each item were recorded by a Mackworth Eye Marker Camera. On high blackout-ratio material, subjects used fewer fixations, shorter fixation time, and shorter scanning time. High blackout-ratio material failed to evoke the students' attention. PMID:16795275

  4. Updated prevalence rates of overweight and obesity in 11- to 17-year-old adolescents in Germany. Results from the telephone-based KiGGS Wave 1 after correction for bias in self-reports.

    PubMed

    Brettschneider, Anna-Kristin; Brettschneidera, Anna-Kristin; Schaffrath Rosario, Angelika; Kuhnert, Ronny; Schmidt, Steffen; Wiegand, Susanna; Ellert, Ute; Kurth, Bärbel-Maria

    2015-11-06

    The nationwide "German Health Interview and Examination Survey for Children and Adolescents" (KiGGS), conducted in 2003-2006, showed an increase in the prevalence rates of overweight and obesity compared to the early 1990s, indicating the need for regularly monitoring. Recently, a follow-up-KiGGS Wave 1 (2009-2012)-was carried out as a telephone-based survey, providing self-reported height and weight. Since self-reports lead to a bias in prevalence rates of weight status, a correction is needed. The aim of the present study is to obtain updated prevalence rates for overweight and obesity for 11- to 17-year olds living in Germany after correction for bias in self-reports. In KiGGS Wave 1, self-reported height and weight were collected from 4948 adolescents during a telephone interview. Participants were also asked about their body perception. From a subsample of KiGGS Wave 1 participants, measurements for height and weight were collected in a physical examination. In order to correct prevalence rates derived from self-reports, weight status categories based on self-reported and measured height and weight were used to estimate a correction formula according to an established procedure under consideration of body perception. The correction procedure was applied and corrected rates were estimated. The corrected prevalence of overweight, including obesity, derived from KiGGS Wave 1, showed that the rate has not further increased compared to the KiGGS baseline survey (18.9 % vs. 18.8 % based on the German reference). The rates of overweight still remain at a high level. The results of KiGGS Wave 1 emphasise the significance of this health issue and the need for prevention of overweight and obesity in children and adolescents.

  5. Heat transfer rate and film cooling effectiveness measurements in a transient cascade

    NASA Astrophysics Data System (ADS)

    Schultz, D. L.; Oldfield, M. L. G.; Jones, T. V.

    1980-09-01

    A transient cascade useful for heat transfer rate measurements is briefly described. The facility employs a free piston which compresses the test gas to temperatures around 450 K and pressures of about 3.5 to 7.5 Atm. The model is initially at room temperature and it is necessary to attain the correct gas to wall temperature ratio. The exit Mach number is set by the inlet total pressure and the pressure in the exit dump tank. Thin film heat transfer gauges are used for the measurement of heat transfer rate, deposited on machineable glass ceramic blades. The inherently fast response of these transducers makes them useful for the investigation of boundary layer transition on blade surfaces and some typical results are included.

  6. Apparatus and method for temperature correction and expanded count rate of inorganic scintillation detectors

    DOEpatents

    Ianakiev, Kiril D [Los Alamos, NM; Hsue, Sin Tao [Santa Fe, NM; Browne, Michael C [Los Alamos, NM; Audia, Jeffrey M [Abiquiu, NM

    2006-07-25

    The present invention includes an apparatus and corresponding method for temperature correction and count rate expansion of inorganic scintillation detectors. A temperature sensor is attached to an inorganic scintillation detector. The inorganic scintillation detector, due to interaction with incident radiation, creates light pulse signals. A photoreceiver processes the light pulse signals to current signals. Temperature correction circuitry that uses a fast light component signal, a slow light component signal, and the temperature signal from the temperature sensor to corrected an inorganic scintillation detector signal output and expanded the count rate.

  7. 77 FR 2910 - Schedule for Rating Disabilities; Evaluation of Scars; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-20

    ...; Evaluation of Scars; Correction AGENCY: Department of Veterans Affairs. ACTION: Final rule; correction... that addresses the Skin, so that it more clearly reflected VA's policies concerning the evaluation of... Rating Disabilities that addresses the Skin, 38 CFR 4.118, by revising the criteria for the evaluation of...

  8. Fast logic?: Examining the time course assumption of dual process theory.

    PubMed

    Bago, Bence; De Neys, Wim

    2017-01-01

    Influential dual process models of human thinking posit that reasoners typically produce a fast, intuitive heuristic (i.e., Type-1) response which might subsequently be overridden and corrected by slower, deliberative processing (i.e., Type-2). In this study we directly tested this time course assumption. We used a two response paradigm in which participants have to give an immediate answer and afterwards are allowed extra time before giving a final response. In four experiments we used a range of procedures (e.g., challenging response deadline, concurrent load) to knock out Type 2 processing and make sure that the initial response was intuitive in nature. Our key finding is that we frequently observe correct, logical responses as the first, immediate response. Response confidence and latency analyses indicate that these initial correct responses are given fast, with high confidence, and in the face of conflicting heuristic responses. Findings suggest that fast and automatic Type 1 processing also cues a correct logical response from the start. We sketch a revised dual process model in which the relative strength of different types of intuitions determines reasoning performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Correcting over 50 years of tobacco industry misinformation.

    PubMed

    Smith, Philip; Bansal-Travers, Maansi; O'Connor, Richard; Brown, Anthony; Banthin, Chris; Guardino-Colket, Sara; Cummings, K Michael

    2011-06-01

    In 2006, a U.S. Federal Court ruled that the major domestic cigarette manufacturers were guilty of conspiring to deny, distort, and minimize the hazards of cigarette smoking to the public and ordered corrective statements to correct these deceptions. This study evaluates the effectiveness of different versions of corrective statements that were proposed to the Court. 239 adult smokers (aged 18-65 years) were randomized to view one of five different versions of corrective statements on five topics (health risks, addiction, low-tar cigarettes, product manipulation, and secondhand smoke); change in knowledge and beliefs were measured before and after viewing the statements, as well as 1 week later. Three of the versions were text-based statements recommended by different parties in the case (Philip Morris, U.S. Department of Justice [DOJ], Interveners), whereas two others were developed at Roswell Park Cancer Institute (RPCI) for this study and utilized pictorial images (emotive and neutral). Data collection and analysis were conducted in Buffalo NY from 2008 to 2009. Regardless of which corrective statement was seen, exposure resulted in a consistent pattern of increased level of knowledge and corrected misperceptions about smoking, although the effects were not large and diminished back toward baseline levels within 1 week. The DOJ, Interveners, and emotive statements elicited a stronger affective response and were rated by respondents as more persuasive (p-value<0.05). The emotive statement was better recalled and drew the respondents' attention in the shortest amount of time. Each of the proposed corrective statements tested helped correct false beliefs about smoking, but sustained impact will likely require repeated exposures to the message. Copyright © 2011. Published by Elsevier Inc.

  10. Pharmacists' Knowledge and Attitudes Towards Upper Respiratory Infections (URI) in Iran: A Cross Sectional Study.

    PubMed

    Eslami, Neda; Eshraghi, Azadeh; Vaseghi, Golnaz; Mehdizadeh, Mona; Masjedi, Moein; Mehrpooya, Maryam

    2016-01-01

    To identify the knowledge and attitudes of community pharmacists towards upper respiratory infections. The pharmacists, who participated in an annual clinical pharmacy congress in Tehran, were enrolled in this study. We conducted a cross-sectional descriptive study to assess the knowledge and attitudes of 72 community pharmacists towards upper respiratory infections (URI) using a questionnaire. We investigated the knowledge and attitudes of pharmacists towards rational antibiotics use in URI in Iran. Also we tried to detect causes of irrational antibiotic use. The response rate of our study was 72%. Of all respondents, 98.61% answered the knowledge question" inappropriate use of antibiotics could lead to drug resistance and would increase drug allergy" correctly. More than half (55.56%) of the community pharmacists believed that pharmacists can be affected by patients' expectations for antibiotics prescription. A majority of pharmacists gave a correct response to questions about beneficial use of corticosteroid in URI (90.28%) and symptoms persistent after 10-14 days even with antibiotic therapy (86.11%). More than half of all pharmacists had misconceptions on antibiotic use for URI in children under 2 years old. More than half of all pharmacists believed that most cases of URI are viral infections. Also, 90.28% of all pharmacists believed that guidelines for antibiotics prescribing may be beneficial in appropriate antibiotic use. According to a high response rate for the question about efficiency of antibiotics prescription guidelines, reliable information on the appropriate use of antibiotics should be more widely available for pharmacists.

  11. To beta block or not to beta block; that is the question.

    PubMed

    Ince, Can

    2015-09-24

    The fast-acting β-1 blocker esmolol has been the center of attention since the landmark article by Morrelli and colleagues suggesting that, in patients with sepsis, reducing heart rate by administering esmolol can result in a survival benefit. However, the use of esmolol for the treatment of sepsis and the underlying mechanism responsible for this benefit remain controversial. This commentary discusses the study by Jacquet-Lagrèze and colleagues, who in a pig model of sepsis tested the hypothesis that administration of esmolol to reduce heart rate may correct sepsis-induced sublingual and gut microcirculatory alterations which are known to be associated with adverse outcome.

  12. Stability of landsat-4 thematic mapper outgassing models

    USGS Publications Warehouse

    Micijevic, E.; Chander, G.

    2006-01-01

    Oscillations in radiometric gains of the short wave infrared (SWIR) bands in Landsat-4 (L4) and Landsat-5 (L5) Thematic Mappers (TMs) are observed through an analysis of detector responses to the Internal Calibrator (IC) pulses. The oscillations are believed to be caused by an interference effect due to a contaminant film buildup on the window of the cryogenically cooled dewar that houses these detectors. This process of contamination, referred to as outgassing effects, has been well characterized using an optical thin-film model that relates detector responses to the accumulated film thickness and its growth rate. The current models for L4 TM are based on average detector responses to the second brightest IC lamp and have been derived from three data sets acquired during different times throughout the instrument's lifetime. Unlike in L5 TM outgassing characterization, it was found that the L4 TM responses to all three IC lamps can be used to provide accurate characterization and correction for outgassing effects. The analysis of single detector responses revealed an up to five percent difference in the estimated oscillating periods and also indicated a gradual variation of contaminant growth rate over the focal plane.

  13. Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

    DOE PAGES

    Lockhart, M.; Henzlova, D.; Croft, S.; ...

    2017-09-20

    Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less

  14. Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockhart, M.; Henzlova, D.; Croft, S.

    Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less

  15. Plasticity as Phenotype: G x E Interaction in a Freshwater Snail

    NASA Astrophysics Data System (ADS)

    Brunkow, P. E.; Calloway, S. A.

    2005-05-01

    Plasticity in morphological development allows species to accommodate environmental variation experienced during growth; however, genetic variation for phenotypic plasticity per se has been relatively under-studied. We utilized the well-documented plastic response of shell development to predator cues in a freshwater snail to quantify genetic variation for plasticity in growth rate and shell shape. Field-caught pairs of snails reproduced in the laboratory to create families of full siblings, which were then divided and allowed to grow in control and predator cue treatments. Predator (crayfish) cues had significant effects on both size-corrected growth rate and shell shape; family identity also significantly affected both final shell shape and growth rate. The interaction between predator treatment and family identity significantly affected snail growth rate but not final shell shape, suggesting genetic variation in the plastic response to predator cues for a physiological variable (growth rate) but not for a variable known to mechanically reduce the risk of predation (shell shape), at least in this population of snails. The possibility that risk of multiple modes of predation (i.e., both fish and crayfish) in some populations might maintain genetic variation in morphological plasticity is discussed.

  16. 45 CFR 5b.7 - Procedures for correction or amendment of records.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... making a request to amend or correct his record shall address his request to the responsible Department... informed of the responsible Department official's decision on the request within that 10 day period. (c) If... individual will be informed in writing of the correction, amendment, or deletion and, if accounting was made...

  17. Structure analysis of tax revenue and inflation rate in Banda Aceh using vector error correction model with multiple alpha

    NASA Astrophysics Data System (ADS)

    Sofyan, Hizir; Maulia, Eva; Miftahuddin

    2017-11-01

    A country has several important parameters to achieve economic prosperity, such as tax revenue and inflation rate. One of the largest revenues of the State Budget in Indonesia comes from the tax sector. Meanwhile, the rate of inflation occurring in a country can be used as an indicator, to measure the good and bad economic problems faced by the country. Given the importance of tax revenue and inflation rate control in achieving economic prosperity, it is necessary to analyze the structure of tax revenue relations and inflation rate. This study aims to produce the best VECM (Vector Error Correction Model) with optimal lag using various alpha and perform structural analysis using the Impulse Response Function (IRF) of the VECM models to examine the relationship of tax revenue, and inflation in Banda Aceh. The results showed that the best model for the data of tax revenue and inflation rate in Banda Aceh City using alpha 0.01 is VECM with optimal lag 2, while the best model for data of tax revenue and inflation rate in Banda Aceh City using alpha 0.05 and 0,1 VECM with optimal lag 3. However, the VECM model with alpha 0.01 yielded four significant models of income tax model, inflation rate of Banda Aceh, inflation rate of health and inflation rate of education in Banda Aceh. While the VECM model with alpha 0.05 and 0.1 yielded one significant model that is income tax model. Based on the VECM models, then there are two structural analysis IRF which is formed to look at the relationship of tax revenue, and inflation in Banda Aceh, the IRF with VECM (2) and IRF with VECM (3).

  18. EAP recordings in ineraid patients--correlations with psychophysical measures and possible implications for patient fitting.

    PubMed

    Zimmerling, Martin J; Hochmair, Erwin S

    2002-04-01

    Objective measurements can be helpful for cochlear implant fitting of difficult populations, as for example very young children. One method, the recording of the electrically evoked compound action potential (EAP), measures the nerve recruitment in the cochlea in response to stimulation through the implant. For coding strategies implemented at a moderate stimulation rate of 250 pps per channel, useful correlations between EAP data and psychophysical data have been already found. With new systems running at higher rates, it is important to check these correlations again. This study investigates the correlations between psychophysical data and EAP measures calculated from EAP amplitude growth functions. EAP data were recorded in 12 Ineraid subjects. Additionally, behavioral thresholds (THR) and maximum acceptable loudness levels (MAL) were determined for stimulation rates of 80 pps and 2,020 pps for each electrode. Useful correlations between EAP data and psychophysical data were found at the low stimulation rate (80 pps). However, at the higher stimulation rate (2,020 pps) correlations were not significant. They were improved substantially, however, by introducing a factor that corrected for disparities due to temporal integration. Incorporation of this factor, which controls for the influence of the stimulation rate on the threshold, improved the correlations between EAP measures recorded at 80 pps and psychophysical MALs measured at 2,020 pps to better than r = 0.70. EAP data as such can only be used to predict behavioral THRs or MCLs at low stimulation rates. To cope with temporal integration effects at higher stimulation rates, EAP data must be rate corrected. The introduction of a threshold-rate-factor is a promising way to achieve that goal. Further investigations need to be performed.

  19. Prediction of shot success for basketball free throws: visual search strategy.

    PubMed

    Uchida, Yusuke; Mizuguchi, Nobuaki; Honda, Masaaki; Kanosue, Kazuyuki

    2014-01-01

    In ball games, players have to pay close attention to visual information in order to predict the movements of both the opponents and the ball. Previous studies have indicated that players primarily utilise cues concerning the ball and opponents' body motion. The information acquired must be effective for observing players to select the subsequent action. The present study evaluated the effects of changes in the video replay speed on the spatial visual search strategy and ability to predict free throw success. We compared eye movements made while observing a basketball free throw by novices and experienced basketball players. Correct response rates were close to chance (50%) at all video speeds for the novices. The correct response rate of experienced players was significantly above chance (and significantly above that of the novices) at the normal speed, but was not different from chance at both slow and fast speeds. Experienced players gazed more on the lower part of the player's body when viewing a normal speed video than the novices. The players likely detected critical visual information to predict shot success by properly moving their gaze according to the shooter's movements. This pattern did not change when the video speed was decreased, but changed when it was increased. These findings suggest that temporal information is important for predicting action outcomes and that such outcomes are sensitive to video speed.

  20. 78 FR 16445 - Shared Responsibility for Employers Regarding Health Coverage; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-15

    ... respect to the shared responsibility for employers regarding employee health coverage. FOR FURTHER...-BL33 Shared Responsibility for Employers Regarding Health Coverage; Correction AGENCY: Internal Revenue... the paragraph heading ``4. Employees Rehired After Termination of Employment or Resuming Service After...

  1. Response to Request for Correction 12002

    EPA Pesticide Factsheets

    Response to Artisan EHS Consulting's Request for Correction 12002 regarding notification requirements for hazardous substances, notifying that the error in question was a typographical error and has been fixed.

  2. Cognitive diagnosis modelling incorporating item response times.

    PubMed

    Zhan, Peida; Jiao, Hong; Liao, Dandan

    2018-05-01

    To provide more refined diagnostic feedback with collateral information in item response times (RTs), this study proposed joint modelling of attributes and response speed using item responses and RTs simultaneously for cognitive diagnosis. For illustration, an extended deterministic input, noisy 'and' gate (DINA) model was proposed for joint modelling of responses and RTs. Model parameter estimation was explored using the Bayesian Markov chain Monte Carlo (MCMC) method. The PISA 2012 computer-based mathematics data were analysed first. These real data estimates were treated as true values in a subsequent simulation study. A follow-up simulation study with ideal testing conditions was conducted as well to further evaluate model parameter recovery. The results indicated that model parameters could be well recovered using the MCMC approach. Further, incorporating RTs into the DINA model would improve attribute and profile correct classification rates and result in more accurate and precise estimation of the model parameters. © 2017 The British Psychological Society.

  3. A New Correction Technique for Strain-Gage Measurements Acquired in Transient-Temperature Environments

    NASA Technical Reports Server (NTRS)

    Richards, W. Lance

    1996-01-01

    Significant strain-gage errors may exist in measurements acquired in transient-temperature environments if conventional correction methods are applied. As heating or cooling rates increase, temperature gradients between the strain-gage sensor and substrate surface increase proportionally. These temperature gradients introduce strain-measurement errors that are currently neglected in both conventional strain-correction theory and practice. Therefore, the conventional correction theory has been modified to account for these errors. A new experimental method has been developed to correct strain-gage measurements acquired in environments experiencing significant temperature transients. The new correction technique has been demonstrated through a series of tests in which strain measurements were acquired for temperature-rise rates ranging from 1 to greater than 100 degrees F/sec. Strain-gage data from these tests have been corrected with both the new and conventional methods and then compared with an analysis. Results show that, for temperature-rise rates greater than 10 degrees F/sec, the strain measurements corrected with the conventional technique produced strain errors that deviated from analysis by as much as 45 percent, whereas results corrected with the new technique were in good agreement with analytical results.

  4. Effect of temporal location of correction of monochromatic aberrations on the dynamic accommodation response

    PubMed Central

    Hampson, Karen M.; Chin, Sem Sem; Mallen, Edward A. H.

    2010-01-01

    Dynamic correction of monochromatic aberrations of the eye is known to affect the accommodation response to a step change in stimulus vergence. We used an adaptive optics system to determine how the temporal location of the correction affects the response. The system consists of a Shack-Hartmann sensor sampling at 20 Hz and a 37-actuator piezoelectric deformable mirror. An extra sensing channel allows for an independent measure of the accommodation level of the eye. The accommodation response of four subjects was measured during a +/− 0.5 D step change in stimulus vergence whilst aberrations were corrected at various time locations. We found that continued correction of aberrations after the step change decreased the gain for disaccommodation, but increased the gain for accommodation. These results could be explained based on the initial lag of accommodation to the stimulus and changes in the level of aberrations before and after the stimulus step change. Future considerations for investigations of the effect of monochromatic aberrations on the dynamic accommodation response are discussed. PMID:21258515

  5. 77 FR 47582 - Great Lakes Pilotage Rates-2013 Annual Review and Adjust; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-09

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 46 CFR Part 401 [Docket No. USCG-2012-0409] RIN 1625-AB89 Great Lakes Pilotage Rates--2013 Annual Review and Adjust; Correction AGENCY: Coast Guard, DHS. ACTION: Notice of proposed rulemaking; correction. SUMMARY: The Coast Guard published a Notice of...

  6. Self-Correcting Electronically-Scanned Pressure Sensor

    NASA Technical Reports Server (NTRS)

    Gross, C.; Basta, T.

    1982-01-01

    High-data-rate sensor automatically corrects for temperature variations. Multichannel, self-correcting pressure sensor can be used in wind tunnels, aircraft, process controllers and automobiles. Offers data rates approaching 100,000 measurements per second with inaccuracies due to temperature shifts held below 0.25 percent (nominal) of full scale over a temperature span of 55 degrees C.

  7. Pedestrians' perception and response towards vehicles during road-crossing at nighttime.

    PubMed

    Balasubramanian, Venkatesh; Bhardwaj, Rahul

    2018-01-01

    Pedestrian being involved in road traffic accidents (RTA) is about 22% of all road traffic related deaths. In this study, we have estimated the pedestrian's response towards an approaching vehicle and the time taken to correctly recognize it while they crossed the road in dim-light nighttime conditions. This is also extendable to cycles and other low powered vehicles. Thirty volunteers participated in this study. A collection of six videos, which comprised of different vehicle scenarios were shown to each of the participants. It was observed that correct identification and time to recognize the vehicle was fastest when light emitting diode (LED) strip was fixed between headlights of a four-wheeler. Average time to recognize a low beam car and a high beam car with an LED strip was 7.62±2.39s and 11.23±2.94s respectively, whereas correct identification rates of the said low beam and high beam cars with LED strips were 93.33% and 86.67% respectively. Earlier when no LED was used, time to recognize low beam car and high beam car without LED strip were 20.55±3.50s and 25.57±4.14s respectively whereas correct identification of low beam car without LED strip and high beam car without LED strip were 90.00% and 56.67% respectively. Pedestrians are therefore less confused and can take right decision while crossing the road - particularly in a poor lighting environment - when there is a demarcating illumination between headlights of vehicle. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. The effect of ambient pressure on well chamber response: Monte Carlo calculated results for the HDR 1000 plus.

    PubMed

    Bohm, Tim D; Griffin, Sheridan L; DeLuca, Paul M; DeWerd, Larry A

    2005-04-01

    The determination of the air kerma strength of a brachytherapy seed is necessary for effective treatment planning. Well ionization chambers are used on site at therapy clinics to determine the air kerma strength of seeds. In this work, the response of the Standard Imaging HDR 1000 Plus well chamber to ambient pressure is examined using Monte Carlo calculations. The experimental work examining the response of this chamber as well as other chambers is presented in a companion paper. The Monte Carlo results show that for low-energy photon sources, the application of the standard temperature pressure PTP correction factor produces an over-response at the reduced air densities/pressures corresponding to high elevations. With photon sources of 20 to 40 keV, the normalized PTP corrected chamber response is as much as 10% to 20% over unity for air densities/pressures corresponding to an elevation of 3048 m (10000 ft) above sea level. At air densities corresponding to an elevation of 1524 m (5000 ft), the normalized PTP-corrected chamber response is 5% to 10% over unity for these photon sources. With higher-energy photon sources (>100 keV), the normalized PTP corrected chamber response is near unity. For low-energy beta sources of 0.25 to 0.50 MeV, the normalized PTP-corrected chamber response is as much as 4% to 12% over unity for air densities/pressures corresponding to an elevation of 3048 m (10000 ft) above sea level. Higher-energy beta sources (>0.75 MeV) have a normalized PTP corrected chamber response near unity. Comparing calculated and measured chamber responses for common 103Pd- and 125I-based brachytherapy seeds show agreement to within 2.7% and 1.9%, respectively. Comparing MCNP calculated chamber responses with EGSnrc calculated chamber responses show agreement to within 3.1% at photon energies of 20 to 40 keV. We conclude that Monte Carlo transport calculations accurately model the response of this well chamber. Further, applying the standard PTP correction factor for this well chamber is insufficient in accounting for the change in chamber response with air pressure for low-energy (<100 keV) photon and low-energy (<0.75 MeV)beta sources.

  9. Transcranial motor evoked potential waveform changes in corrective fusion for adolescent idiopathic scoliosis.

    PubMed

    Kobayashi, Kazuyoshi; Imagama, Shiro; Ito, Zenya; Ando, Kei; Hida, Tetsuro; Ito, Kenyu; Tsushima, Mikito; Ishikawa, Yoshimoto; Matsumoto, Akiyuki; Nishida, Yoshihiro; Ishiguro, Naoki

    2017-01-01

    OBJECTIVE Corrective surgery for spinal deformities can lead to neurological complications. Several reports have described spinal cord monitoring in surgery for spinal deformity, but only a few have included patients younger than 20 years with adolescent idiopathic scoliosis (AIS). The goal of this study was to evaluate the characteristics of cases with intraoperative transcranial motor evoked potential (Tc-MEP) waveform deterioration during posterior corrective fusion for AIS. METHODS A prospective database was reviewed, comprising 68 patients with AIS who were treated with posterior corrective fusion in a prospective database. A total of 864 muscles in the lower extremities were chosen for monitoring, and acceptable baseline responses were obtained from 819 muscles (95%). Intraoperative Tc-MEP waveform deterioration was defined as a decrease in intraoperative amplitude of ≥ 70% of the control waveform. Age, Cobb angle, flexibility, operative time, estimated blood loss (EBL), intraoperative body temperature, blood pressure, number of levels fused, and correction rate were examined in patients with and without waveform deterioration. RESULTS The patients (3 males and 65 females) had an average age of 14.4 years (range 11-19 years). The mean Cobb angles before and after surgery were 52.9° and 11.9°, respectively, giving a correction rate of 77.4%. Fourteen patients (20%) exhibited an intraoperative waveform change, and these occurred during incision (14%), after screw fixation (7%), during the rotation maneuver (64%), during placement of the second rod after the rotation maneuver (7%), and after intervertebral compression (7%). Most waveform changes recovered after decreased correction or rest. No patient had a motor deficit postoperatively. In multivariate analysis, EBL (OR 1.001, p = 0.085) and number of levels fused (OR 1.535, p = 0.045) were associated with waveform deterioration. CONCLUSIONS Waveform deterioration commonly occurred during rotation maneuvers and more frequently in patients with a larger preoperative Cobb angle. The significant relationships of EBL and number of levels fused with waveform deterioration suggest that these surgical invasions may be involved in waveform deterioration.

  10. Compensating for Effects of Humidity on Electronic Noses

    NASA Technical Reports Server (NTRS)

    Homer, Margie; Ryan, Margaret A.; Manatt, Kenneth; Zhou, Hanying; Manfreda, Allison

    2004-01-01

    A method of compensating for the effects of humidity on the readouts of electronic noses has been devised and tested. The method is especially appropriate for use in environments in which humidity is not or cannot be controlled for example, in the vicinity of a chemical spill, which can be accompanied by large local changes in humidity. Heretofore, it has been common practice to treat water vapor as merely another analyte, the concentration of which is determined, along with that of the other analytes, in a computational process based on deconvolution. This practice works well, but leaves room for improvement: changes in humidity can give rise to large changes in electronic-nose responses. If corrections for humidity are not made, the large humidity-induced responses may swamp smaller responses associated with low concentrations of analytes. The present method offers an improvement. The underlying concept is simple: One augments an electronic nose with a separate humidity and a separate temperature sensor. The outputs of the humidity and temperature sensors are used to generate values that are subtracted from the readings of the other sensors in an electronic nose to correct for the temperature-dependent contributions of humidity to those readings. Hence, in principle, what remains after corrections are the contributions of the analytes only. Laboratory experiments on a first-generation electronic nose have shown that this method is effective and improves the success rate of identification of analyte/ water mixtures. Work on a second-generation device was in progress at the time of reporting the information for this article.

  11. Conjunctive and Disjunctive Extensions of the Least Squares Distance Model of Cognitive Diagnosis

    ERIC Educational Resources Information Center

    Dimitrov, Dimiter M.; Atanasov, Dimitar V.

    2012-01-01

    Many models of cognitive diagnosis, including the "least squares distance model" (LSDM), work under the "conjunctive" assumption that a correct item response occurs when all latent attributes required by the item are correctly performed. This article proposes a "disjunctive" version of the LSDM under which the correct item response occurs when "at…

  12. The Utility of K-Correction To Adjust for a Defensive Response Set on the MMPI.

    ERIC Educational Resources Information Center

    Putzke, John D.; Williams, Mark A.; Daniel, F. Joseph; Boll, Thomas J.

    1999-01-01

    Examined the usefulness of the K-correction procedure to adjust for a defensive response set on the Minnesota Multiphasic Personality Inventory (MMPI) with 61 patients being evaluated for lung transplants. Results support the use of the K-correction procedure for this patient group. Implications for MMPI use are discussed. (SLD)

  13. Item Type and Gender Differences on the Mental Rotations Test

    ERIC Educational Resources Information Center

    Voyer, Daniel; Doyle, Randi A.

    2010-01-01

    This study investigated gender differences on the Mental Rotations Test (MRT) as a function of item and response types. Accordingly, 86 male and 109 female undergraduate students completed the MRT without time limits. Responses were coded as reflecting two correct (CC), one correct and one wrong (CW), two wrong (WW), one correct and one blank…

  14. How to Correct a Task Error: Task-Switch Effects Following Different Types of Error Correction

    ERIC Educational Resources Information Center

    Steinhauser, Marco

    2010-01-01

    It has been proposed that switch costs in task switching reflect the strengthening of task-related associations and that strengthening is triggered by response execution. The present study tested the hypothesis that only task-related responses are able to trigger strengthening. Effects of task strengthening caused by error corrections were…

  15. 76 FR 39006 - Medicare Program; Hospital Inpatient Value-Based Purchasing Program; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-05

    ... Pneumonia (PN) 30-Day .8818 Mortality Rate. 7. On page 26516, Table 7 is corrected to read as follows... Day Mortality Rate. MORT-30 PN Pneumonia (PN) 30-Day .9021 Mortality Rate. 8. On page 26527, in the...

  16. Can small field diode correction factors be applied universally?

    PubMed

    Liu, Paul Z Y; Suchowerska, Natalka; McKenzie, David R

    2014-09-01

    Diode detectors are commonly used in dosimetry, but have been reported to over-respond in small fields. Diode correction factors have been reported in the literature. The purpose of this study is to determine whether correction factors for a given diode type can be universally applied over a range of irradiation conditions including beams of different qualities. A mathematical relation of diode over-response as a function of the field size was developed using previously published experimental data in which diodes were compared to an air core scintillation dosimeter. Correction factors calculated from the mathematical relation were then compared those available in the literature. The mathematical relation established between diode over-response and the field size was found to predict the measured diode correction factors for fields between 5 and 30 mm in width. The average deviation between measured and predicted over-response was 0.32% for IBA SFD and PTW Type E diodes. Diode over-response was found to be not strongly dependent on the type of linac, the method of collimation or the measurement depth. The mathematical relation was found to agree with published diode correction factors derived from Monte Carlo simulations and measurements, indicating that correction factors are robust in their transportability between different radiation beams. Copyright © 2014. Published by Elsevier Ireland Ltd.

  17. Continuous quantum error correction for non-Markovian decoherence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oreshkov, Ognyan; Brun, Todd A.; Communication Sciences Institute, University of Southern California, Los Angeles, California 90089

    2007-08-15

    We study the effect of continuous quantum error correction in the case where each qubit in a codeword is subject to a general Hamiltonian interaction with an independent bath. We first consider the scheme in the case of a trivial single-qubit code, which provides useful insights into the workings of continuous error correction and the difference between Markovian and non-Markovian decoherence. We then study the model of a bit-flip code with each qubit coupled to an independent bath qubit and subject to continuous correction, and find its solution. We show that for sufficiently large error-correction rates, the encoded state approximatelymore » follows an evolution of the type of a single decohering qubit, but with an effectively decreased coupling constant. The factor by which the coupling constant is decreased scales quadratically with the error-correction rate. This is compared to the case of Markovian noise, where the decoherence rate is effectively decreased by a factor which scales only linearly with the rate of error correction. The quadratic enhancement depends on the existence of a Zeno regime in the Hamiltonian evolution which is absent in purely Markovian dynamics. We analyze the range of validity of this result and identify two relevant time scales. Finally, we extend the result to more general codes and argue that the performance of continuous error correction will exhibit the same qualitative characteristics.« less

  18. 10 CFR 850.5 - Dispute resolution.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... accept a petition from a worker unless the worker requested the responsible employer to correct the violation, and the responsible employer refused or failed to take corrective action within a reasonable time...

  19. Analysis of self-reported versus biomarker based smoking prevalence: methodology to compute corrected smoking prevalence rates.

    PubMed

    Jain, Ram B

    2017-07-01

    Prevalence of smoking is needed to estimate the need for future public health resources. To compute and compare smoking prevalence rates by using self-reported smoking statuses, two serum cotinine (SCOT) based biomarker methods, and one urinary 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanol (NNAL) based biomarker method. These estimates were then used to develop correction factors to be applicable to self-reported prevalences to arrive at corrected smoking prevalence rates. Data from National Health and Nutrition Examination Survey (NHANES) for 2007-2012 for those aged ≥20 years (N = 16826) were used. Self-reported prevalence rate for the total population computed as the weighted number of self-reported smokers divided by weighted number of all participants was 21.6% and 24% when computed by weighted number of self-reported smokers divided by the weighted number of self-reported smokers and nonsmokers. The corrected prevalence rate was found to be 25.8%. A 1% underestimate in smoking prevalence is equivalent to not being able to identify 2.2 million smokers in US in a given year. This underestimation, if not corrected, could lead to serious gap in the public health services available and needed to provide adequate preventive and corrective treatment to smokers.

  20. Delayed system response times affect immediate physiology and the dynamics of subsequent button press behavior.

    PubMed

    Kohrs, Christin; Hrabal, David; Angenstein, Nicole; Brechmann, André

    2014-11-01

    System response time research is an important issue in human-computer interactions. Experience with technical devices and general rules of human-human interactions determine the user's expectation, and any delay in system response time may lead to immediate physiological, emotional, and behavioral consequences. We investigated such effects on a trial-by-trial basis during a human-computer interaction by measuring changes in skin conductance (SC), heart rate (HR), and the dynamics of button press responses. We found an increase in SC and a deceleration of HR for all three delayed system response times (0.5, 1, 2 s). Moreover, the data on button press dynamics was highly informative since subjects repeated a button press with more force in response to delayed system response times. Furthermore, the button press dynamics could distinguish between correct and incorrect decisions and may thus even be used to infer the uncertainty of a user's decision. Copyright © 2014 Society for Psychophysiological Research.

  1. An evaluation of the effect of JPEG, JPEG2000, and H.264/AVC on CQR codes decoding process

    NASA Astrophysics Data System (ADS)

    Vizcarra Melgar, Max E.; Farias, Mylène C. Q.; Zaghetto, Alexandre

    2015-02-01

    This paper presents a binarymatrix code based on QR Code (Quick Response Code), denoted as CQR Code (Colored Quick Response Code), and evaluates the effect of JPEG, JPEG2000 and H.264/AVC compression on the decoding process. The proposed CQR Code has three additional colors (red, green and blue), what enables twice as much storage capacity when compared to the traditional black and white QR Code. Using the Reed-Solomon error-correcting code, the CQR Code model has a theoretical correction capability of 38.41%. The goal of this paper is to evaluate the effect that degradations inserted by common image compression algorithms have on the decoding process. Results show that a successful decoding process can be achieved for compression rates up to 0.3877 bits/pixel, 0.1093 bits/pixel and 0.3808 bits/pixel for JPEG, JPEG2000 and H.264/AVC formats, respectively. The algorithm that presents the best performance is the H.264/AVC, followed by the JPEG2000, and JPEG.

  2. Impact of supervised student optometry consultations on the patient experience.

    PubMed

    Bentley, Sharon A; Trevaskis, Jane E; Woods, Craig A; Guest, Daryl; Watt, Kathleen G

    2018-03-01

    Understanding patient perceptions of having students involved in their clinical care is important as we strive to develop optimal models of care that integrate teaching with the best possible experience for the patient. The aim was to ascertain the impact of supervised optometry student consultations on the patient experience. A survey comprising 45 questions was mailed to consecutive adult patients who had undergone a comprehensive eye examination at the Australian College of Optometry over a four-week period. Responses were received from 193 patients who had a student involved in their care (44 per cent response rate; 156 completed correctly) and 177 who did not have a student involved (32 per cent response rate; 105 completed correctly). There was no significant difference in overall patient satisfaction between the teaching and non-teaching clinics (p = 0.18). Over 87 per cent of patients in the teaching clinic felt completely comfortable with a student examining them, 44 per cent felt their care was better because a student was involved and 97 per cent rated the overall performance of the student as very good or good. Although 12 per cent would rather have seen only the optometrist and three per cent would not be happy to have a student involved in their eye care again, 100 per cent believed it is important for students to work with patients. The most common reason for student acceptance was the importance of students needing opportunities to learn. The main reasons for unwillingness to have a student involved in future were the additional time taken and prolonged testing. The findings of this study suggest that most patients view supervised student involvement in their optometric care as an important and highly positive experience. However, efforts should be made to avoid excessively long consultations and prolonged testing. Concerns about patient satisfaction and acceptance are largely unwarranted and should not prevent optometry students being involved in patient care. © 2017 Optometry Australia.

  3. Terms used for isolation practices by nurses at an academic medical center

    PubMed Central

    Landers, Timothy; McWalters, Jessica; Behta, Maryam; Bufe, Gina; Ross, Barbara; Vawdrey, David K.; Larson, Elaine

    2010-01-01

    Aim This paper is a report of a study to determine if the terms used by nurses to describe isolation precautions are associated with correct identification of required personal protective equipment. Background Isolation measures are important in the prevention of health care-associated infections. The terms used to describe categories of isolation have changed in response to new pathogens and with advances in infection prevention. Methods For three months in2009, nurses from an academic medical center on the East Coast of the United States of America completed a survey consisting of ten clinical scenarios which asked about recommended personal protective equipment and for the name of the recommended isolation type. Correct identification of required personal protective equipment was compared to use of an approved isolation category term, controlling for infection knowledge and demographic variables. Results Three hundred and seventeen nurses gave responses to2, 215 clinical scenarios. Use of non-approved category terms was associated with statistically significantly lower rates of correct personal protective equipment identification compared to use of an approved term (62.2% vs. 77.8%; p<.001). Specific PPE was also selected for use when not indicated--including gowns (42%), N-95 respirators (13%), fluid shield masks(13%) and sterile gloves (6%). Conclusion Inconsistent terminology for isolation precautions may contribute to variations in practice. Adoption of internationally-accepted and standardized category terms may improve adherence to these precautions. PMID:20722801

  4. Contribution of whole platelet aggregometry to the endovascular management of unruptured aneurysms: an institutional experience.

    PubMed

    Aoun, S G; Welch, B G; Pride, L G; White, J; Novakovic, R; Hoes, K; Sarode, R

    2017-10-01

    Stent-assisted coiling of intracranial aneurysms is an efficient alternative treatment to surgical clipping but requires prolonged antiplatelet therapy. Some patients are non-responsive to aspirin and/or clopidogrel. To analyze the implications of this assessment using the 'whole blood aggregometry (WBA) by impedance' technique. The Southwestern Tertiary Aneurysm Registry was reviewed between 2002 and 2012 for patients with unruptured aneurysms treated with stent-assisted coiling. The study population was divided into patients who were tested preoperatively for platelet responsiveness to aspirin and clopidogrel ('tested' patients) and those who were not ('non-tested'). Where necessary, tested patients received additional doses of antiplatelet drugs to achieve adequate platelet inhibition. Endpoints included the incidence of non-responsiveness, the rates of thrombotic and hemorrhagic complications, and the rates of permanent morbidity and mortality. A total of 266 patients fulfilled our selection criteria: 114 non-tested patients who underwent 121 procedures, and 152 tested patients who underwent 171 procedures. The two groups did not vary significantly in patient age, gender, and aneurysms location. Aspirin non-responsiveness was detected in 3 patients (1.75%) and clopidogrel non-responsiveness in 21 patients (12.3%). Non-tested patients had an 11.6% rate of thrombotic complications with a 4.1% permanent morbidity or mortality rate versus 2.3% and 0.6% in tested patients (p=0.0013). The incidence of hemorrhagic complications was similar between the two groups. Preoperative platelet inhibition testing using WBA can be useful to assess and correct antiaggregant non-responsiveness, and may reduce postoperative mortality and permanent morbidity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. Comparison of pain neurophysiology knowledge among health sciences students: a cross-sectional study.

    PubMed

    Adillón, Cristina; Lozano, Èrik; Salvat, Isabel

    2015-10-22

    A key tool for use in approaching chronic pain treatment is educating patients to reconceptualize pain. Thus, health professionals are fundamental to the transmission of pain information to patients. Because their understanding of pain is acquired during the educational process, the aim of this study was to compare the knowledge about pain neurophysiology in first and final-year students from three different health science programs at a single University to determine their gain in knowledge using a well-known questionnaire designed to evaluate the understanding of pain. The Neurophysiology of Pain Questionnaire (19 closed-ended questions) was administered to students in their first and final years of study in Medicine, Physiotherapy, or Nutrition. The percentage of correct responses was determined and comparisons of the results were analyzed between the programs as well as between the first and final years of study within each program. For all tests, p-values were two-sided, and results with p-values below 0.05 were considered statistically significant. The participation rate was greater than 51% (n = 285). The mean percentage of correct responses, reported as mean (SD), among the first year students was 42.14 (12.23), without significant statistical differences detected between the programs. The mean percentages of correct responses for students in their final year were as follows: Medicine, 54.38 (13.87); Physiotherapy, 68.92 (16.22); Nutrition, 42.34 (10.11). We found statistically significant differences among all three programs and between the first and final years in Medicine and Physiotherapy. A question-by-question analysis showed that the percentage of correct responses for questions related to the biopsychosocial aspects of pain was higher for students in Physiotherapy than those in Medicine. Students in their final years of Medicine and Physiotherapy programs know more about the neurophysiology of pain than students in their first years of these programs, however there are some questions where first years students have better results. Physiotherapy students have greater knowledge of neurophysiology of pain than Medicine students, especially the biopsychosocial aspects. Even so, their understanding may not be sufficient and does not guarantee an approach to chronic pain that will help patients reconceptualize their pain.

  6. Inmate Violence and Correctional Staff Burnout: The Role of Sense of Security, Gender, and Job Characteristics.

    PubMed

    Isenhardt, Anna; Hostettler, Ueli

    2016-12-01

    Violence in the workplace has serious consequences for employees and organizations. Based on a survey in early 2012 among employees from all work areas of 89 of the total 112 correctional facilities in Switzerland resulting in a sample of 2,045 employees (response rate 48.5%), this study (a) analyzed whether victimization has an impact on correctional staff burnout, (b) tested the hypothetical mediating role of sense of security in the relationship between victimization and burnout, and (c) included gender and job characteristics because work experiences and exposure to violence of staff differ strongly with gender and work tasks. Two different forms of violence were considered: (a) experienced violence (inmates-on-staff) and (b) observed violence (inmate-on-inmate). Analysis was carried out using structural equation modeling. Results show that victimization and witnessing violence between inmates negatively affect the personal sense of security and increase correctional staff burnout. In addition, the sense of security mediated the effect from experienced and observed violence on burnout. Gender and job characteristics also proved to be important. This is especially true for staff working as correctional officers and for employees working with young inmates and with inmates awaiting trial who reported a greater exposure to violence and a lower sense of security. The study adds to the knowledge on violence and its outcomes in corrections and contributes to the literature on the consequences of workplace violence in general and, specifically, in social service occupations.

  7. Fatigue Crack Growth Rate and Stress-Intensity Factor Corrections for Out-of-Plane Crack Growth

    NASA Technical Reports Server (NTRS)

    Forth, Scott C.; Herman, Dave J.; James, Mark A.

    2003-01-01

    Fatigue crack growth rate testing is performed by automated data collection systems that assume straight crack growth in the plane of symmetry and use standard polynomial solutions to compute crack length and stress-intensity factors from compliance or potential drop measurements. Visual measurements used to correct the collected data typically include only the horizontal crack length, which for cracks that propagate out-of-plane, under-estimates the crack growth rates and over-estimates the stress-intensity factors. The authors have devised an approach for correcting both the crack growth rates and stress-intensity factors based on two-dimensional mixed mode-I/II finite element analysis (FEA). The approach is used to correct out-of-plane data for 7050-T7451 and 2025-T6 aluminum alloys. Results indicate the correction process works well for high DeltaK levels but fails to capture the mixed-mode effects at DeltaK levels approaching threshold (da/dN approximately 10(exp -10) meter/cycle).

  8. Impact of Feedback on Three Phases of Performance Monitoring

    PubMed Central

    Appelgren, Alva; Penny, William; Bengtsson, Sara L

    2013-01-01

    We investigated if certain phases of performance monitoring show differential sensitivity to external feedback and thus rely on distinct mechanisms. The phases of interest were: the error phase (FE), the phase of the correct response after errors (FEC), and the phase of correct responses following corrects (FCC). We tested accuracy and reaction time (RT) on 12 conditions of a continuous-choice-response task; the 2-back task. External feedback was either presented or not in FE and FEC, and delivered on 0%, 20%, or 100% of FCC trials. The FCC20 was matched to FE and FEC in the number of sounds received so that we could investigate when external feedback was most valuable to the participants. We found that external feedback led to a reduction in accuracy when presented on all the correct responses. Moreover, RT was significantly reduced for FCC100, which in turn correlated with the accuracy reduction. Interestingly, the correct response after an error was particularly sensitive to external feedback since accuracy was reduced when external feedback was presented during this phase but not for FCC20. Notably, error-monitoring was not influenced by feedback-type. The results are in line with models suggesting that the internal error-monitoring system is sufficient in cognitively demanding tasks where performance is ∼ 80%, as well as theories stipulating that external feedback directs attention away from the task. Our data highlight the first correct response after an error as particularly sensitive to external feedback, suggesting that important consolidation of response strategy takes place here. PMID:24217138

  9. Improving the analysis of composite endpoints in rare disease trials.

    PubMed

    McMenamin, Martina; Berglind, Anna; Wason, James M S

    2018-05-22

    Composite endpoints are recommended in rare diseases to increase power and/or to sufficiently capture complexity. Often, they are in the form of responder indices which contain a mixture of continuous and binary components. Analyses of these outcomes typically treat them as binary, thus only using the dichotomisations of continuous components. The augmented binary method offers a more efficient alternative and is therefore especially useful for rare diseases. Previous work has indicated the method may have poorer statistical properties when the sample size is small. Here we investigate small sample properties and implement small sample corrections. We re-sample from a previous trial with sample sizes varying from 30 to 80. We apply the standard binary and augmented binary methods and determine the power, type I error rate, coverage and average confidence interval width for each of the estimators. We implement Firth's adjustment for the binary component models and a small sample variance correction for the generalized estimating equations, applying the small sample adjusted methods to each sub-sample as before for comparison. For the log-odds treatment effect the power of the augmented binary method is 20-55% compared to 12-20% for the standard binary method. Both methods have approximately nominal type I error rates. The difference in response probabilities exhibit similar power but both unadjusted methods demonstrate type I error rates of 6-8%. The small sample corrected methods have approximately nominal type I error rates. On both scales, the reduction in average confidence interval width when using the adjusted augmented binary method is 17-18%. This is equivalent to requiring a 32% smaller sample size to achieve the same statistical power. The augmented binary method with small sample corrections provides a substantial improvement for rare disease trials using composite endpoints. We recommend the use of the method for the primary analysis in relevant rare disease trials. We emphasise that the method should be used alongside other efforts in improving the quality of evidence generated from rare disease trials rather than replace them.

  10. 78 FR 53152 - Prescription Drug User Fee Rates for Fiscal Year 2014; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ...] Prescription Drug User Fee Rates for Fiscal Year 2014; Correction AGENCY: Food and Drug Administration, HHS... ``Prescription Drug User Fee Rates for Fiscal Year 2014'' that appeared in the Federal Register of August 2, 2013 (78 FR 46980). The document announced the Fiscal Year 2014 fee rates for the Prescription Drug User...

  11. Recognition of student names past: a longitudinal study with N = 1.

    PubMed

    Huang, I N

    1997-01-01

    Recognition of names of former students taught at different times by a middle-aged college professor was tested, to investigate recognition memory over a time span ranging from 6 months to 26.5 years. The relationship between the d', a measure of strength of memory, and the retention interval can be best described by a logarithmic function characterized by a rapid initial drop followed by a slow forgetting rate. The correct responses (hits and rejections) had higher confidence and shorter response time than did the incorrect responses (false alarms and misses). The results show that an ecologically realistic longitudinal study with N = 1 can provide a valuable means in the study of human memory with very long retention intervals, which have not yet been investigated in the laboratory.

  12. Response to Request for Correction #10007

    EPA Pesticide Factsheets

    Response to the American Chemistry Council's Request for Correction #10007 that challenged the objectivity and utility of statements in the EPA Bisphenol A Action Plan and refusal to edit the EPA Bisphenol A Action Plan.

  13. How to Collect National Institute of Standards and Technology (NIST) Traceable Fluorescence Excitation and Emission Spectra.

    PubMed

    Gilmore, Adam Matthew

    2014-01-01

    Contemporary spectrofluorimeters comprise exciting light sources, excitation and emission monochromators, and detectors that without correction yield data not conforming to an ideal spectral response. The correction of the spectral properties of the exciting and emission light paths first requires calibration of the wavelength and spectral accuracy. The exciting beam path can be corrected up to the sample position using a spectrally corrected reference detection system. The corrected reference response accounts for both the spectral intensity and drift of the exciting light source relative to emission and/or transmission detector responses. The emission detection path must also be corrected for the combined spectral bias of the sample compartment optics, emission monochromator, and detector. There are several crucial issues associated with both excitation and emission correction including the requirement to account for spectral band-pass and resolution, optical band-pass or neutral density filters, and the position and direction of polarizing elements in the light paths. In addition, secondary correction factors are described including (1) subtraction of the solvent's fluorescence background, (2) removal of Rayleigh and Raman scattering lines, as well as (3) correcting for sample concentration-dependent inner-filter effects. The importance of the National Institute of Standards and Technology (NIST) traceable calibration and correction protocols is explained in light of valid intra- and interlaboratory studies and effective spectral qualitative and quantitative analyses including multivariate spectral modeling.

  14. Ten Frequently Asked Questions About Veterans’ Transitions: Results of a Decade of RAND Work on Veteran Life

    DTIC Science & Technology

    2016-01-01

    a much higher response rate and samples both household units and people living in group quarters, such as college residence halls and correctional...voluntary reasons, such as needing a break or dislik- ing their previous job. Given that reservists already accumulate paid leave while serving on active...commence college during that year and others spend several months engaged in job search. However, after this initial period, the earning premium steadily

  15. Domestic Catastrophes Flow Through Six Distinct Phases: An Analysis of the Los Angeles Riots of 1992 and Hurricane Katrina in 2005

    DTIC Science & Technology

    2010-04-12

    truancy, exploding crime rates, and waning family values that created a sense of desolation within the community.23 Drive-by shootings killed three...Fire Depart- ment. 51 Augmenting the response with National Guard forces also helped stop the increase in fires and crimes in the area.62 Just before... seditions and insurrections. While Federalist No. 29 recommended forming a highly trained militia to a:pply necessary force correctly.2 The Calling

  16. Measuring Intervention Effectiveness: The Benefits of an Item Response Theory Approach

    ERIC Educational Resources Information Center

    McEldoon, Katherine; Cho, Sun-Joo; Rittle-Johnson, Bethany

    2012-01-01

    Assessing the effectiveness of educational interventions relies on quantifying differences between interventions groups over time in a between-within design. Binary outcome variables (e.g., correct responses versus incorrect responses) are often assessed. Widespread approaches use percent correct on assessments, and repeated measures analysis of…

  17. Incidence of Speech-Correcting Surgery in Children With Isolated Cleft Palate.

    PubMed

    Gustafsson, Charlotta; Heliövaara, Arja; Leikola, Junnu; Rautio, Jorma

    2018-01-01

    Speech-correcting surgeries (pharyngoplasty) are performed to correct velopharyngeal insufficiency (VPI). This study aimed to analyze the need for speech-correcting surgery in children with isolated cleft palate (ICP) and to determine differences among cleft extent, gender, and primary technique used. In addition, we assessed the timing and number of secondary procedures performed and the incidence of operated fistulas. Retrospective medical chart review study from hospital archives and electronic records. These comprised the 423 consecutive nonsyndromic children (157 males and 266 females) with ICP treated at the Cleft Palate and Craniofacial Center of Helsinki University Hospital during 1990 to 2016. The total incidence of VPI surgery was 33.3% and the fistula repair rate, 7.8%. Children with cleft of both the hard and soft palate (n = 300) had a VPI secondary surgery rate of 37.3% (fistula repair rate 10.7%), whereas children with only cleft of the soft palate (n = 123) had a corresponding rate of 23.6% (fistula repair rate 0.8%). Gender and primary palatoplasty technique were not considered significant factors in need for VPI surgery. The majority of VPI surgeries were performed before school age. One fifth of patients receiving speech-correcting surgery had more than one subsequent procedure. The need for speech-correcting surgery and fistula repair was related to the severity of the cleft. Although the majority of the corrective surgeries were done before the age of 7 years, a considerable number were performed at a later stage, necessitating long-term observation.

  18. Influence of Alcohol Use on Neural Response to Go/No-Go Task in College Drinkers

    PubMed Central

    Ahmadi, Aral; Pearlson, Godfrey D; Meda, Shashwath A; Dager, Alecia; Potenza, Marc N; Rosen, Rivkah; Austad, Carol S; Raskin, Sarah A; Fallahi, Carolyn R; Tennen, Howard; Wood, Rebecca M; Stevens, Michael C

    2013-01-01

    Impaired inhibition of prepotent motor response may represent an important risk factor for alcoholism. Alcohol use may also increase impulsive behavior, including impaired response inhibition. Little is known about the brain function underlying response inhibition among college-age drinkers based on their drinking patterns, despite college-age drinkers demonstrating high rates of alcohol-use disorders. Our major objective was to compare behavior and associated brain activity measured with fMRI during a response-inhibition task in matched heavy- and light-alcohol-drinking college students. Participants were light (N=36) and heavy (N=56) drinkers, aged 18–20 years. We characterized blood oxygen level-dependent (BOLD) responses, while participants performed an fMRI Go/No-Go task to quantify inhibitory behavior and brain activity. Behaviorally, group performance differences were observed for Go correct-hit and No-Go false-alarm reaction times with increased reaction times in heavy compared with light drinkers. During fMRI No-Go correct rejections, light drinkers exhibited greater BOLD response than did heavy drinkers in left supplementary motor area (SMA), bilateral parietal lobule, right hippocampus, bilateral middle frontal gyrus, left superior temporal gyrus, and cingulate gyrus/anterior cingulate cortex (Brodmann area 24). Group differences in Go/No-Go-related regional activations correlated with alcohol- and impulsivity-related measures. These findings suggest that heavy alcohol drinkers may have dysfunction in brain regions underlying attention and response inhibition, leading to diminished abilities to suppress prepotent responding. The extent to which these tendencies relate to impulsive decision-making and behaviors in real-life settings and may guide intervention development warrants additional investigation. PMID:23670589

  19. 75 FR 11502 - Schedule of Water Charges; Correction

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ... DELAWARE RIVER BASIN COMMISSION 18 CFR Part 410 Schedule of Water Charges; Correction AGENCY: Delaware River Basin Commission. ACTION: Proposed rule; correction. SUMMARY: This document corrects the... of water charges. This correction clarifies that the amended rates are proposed to take effect in two...

  20. Dead time corrections for inbeam γ-spectroscopy measurements

    NASA Astrophysics Data System (ADS)

    Boromiza, M.; Borcea, C.; Negret, A.; Olacel, A.; Suliman, G.

    2017-08-01

    Relatively high counting rates were registered in a proton inelastic scattering experiment on 16O and 28Si using HPGe detectors which was performed at the Tandem facility of IFIN-HH, Bucharest. In consequence, dead time corrections were needed in order to determine the absolute γ-production cross sections. Considering that the real counting rate follows a Poisson distribution, the dead time correction procedure is reformulated in statistical terms. The arriving time interval between the incoming events (Δt) obeys an exponential distribution with a single parameter - the average of the associated Poisson distribution. We use this mathematical connection to calculate and implement the dead time corrections for the counting rates of the mentioned experiment. Also, exploiting an idea introduced by Pommé et al., we describe a consistent method for calculating the dead time correction which completely eludes the complicated problem of measuring the dead time of a given detection system. Several comparisons are made between the corrections implemented through this method and by using standard (phenomenological) dead time models and we show how these results were used for correcting our experimental cross sections.

  1. Performance of the STIS CCD Dark Rate Temperature Correction

    NASA Astrophysics Data System (ADS)

    Branton, Doug; STScI STIS Team

    2018-06-01

    Since July 2001, the Space Telescope Imaging Spectrograph (STIS) onboard Hubble has operated on its Side-2 electronics due to a failure in the primary Side-1 electronics. While nearly identical, Side-2 lacks a functioning temperature sensor for the CCD, introducing a variability in the CCD operating temperature. Previous analysis utilized the CCD housing temperature telemetry to characterize the relationship between the housing temperature and the dark rate. It was found that a first-order 7%/°C uniform dark correction demonstrated a considerable improvement in the quality of dark subtraction on Side-2 era CCD data, and that value has been used on all Side-2 CCD darks since. In this report, we show how this temperature correction has performed historically. We compare the current 7%/°C value against the ideal first-order correction at a given time (which can vary between ~6%/°C and ~10%/°C) as well as against a more complex second-order correction that applies a unique slope to each pixel as a function of dark rate and time. At worst, the current correction has performed ~1% worse than the second-order correction. Additionally, we present initial evidence suggesting that the variability in pixel temperature-sensitivity is significant enough to warrant a temperature correction that considers pixels individually rather than correcting them uniformly.

  2. A Simulation Study on Methods of Correcting for the Effects of Extreme Response Style

    ERIC Educational Resources Information Center

    Wetzel, Eunike; Böhnke, Jan R.; Rose, Norman

    2016-01-01

    The impact of response styles such as extreme response style (ERS) on trait estimation has long been a matter of concern to researchers and practitioners. This simulation study investigated three methods that have been proposed for the correction of trait estimates for ERS effects: (a) mixed Rasch models, (b) multidimensional item response models,…

  3. A new face of sleep: The impact of post-learning sleep on recognition memory for face-name associations

    PubMed Central

    Maurer, Leonie; Zitting, Kirsi-Marja; Elliott, Kieran; Czeisler, Charles A.; Ronda, Joseph M.; Duffy, Jeanne F.

    2015-01-01

    Sleep has been demonstrated to improve consolidation of many types of new memories. However, few prior studies have examined how sleep impacts learning of face-name associations. The recognition of a new face along with the associated name is an important human cognitive skill. Here we investigated whether post-presentation sleep impacts recognition memory of new face-name associations in healthy adults. Fourteen participants were tested twice. Each time, they were presented 20 photos of faces with a corresponding name. Twelve hours later, they were shown each face twice, once with the correct and once with an incorrect name, and asked if each face-name combination was correct and to rate their confidence. In one condition the 12-hour interval between presentation and recall included an 8-hour nighttime sleep opportunity (“Sleep”), while in the other condition they remained awake (“Wake”). There were more correct and highly confident correct responses when the interval between presentation and recall included a sleep opportunity, although improvement between the “Wake” and “Sleep” conditions was not related to duration of sleep or any sleep stage. These data suggest that a nighttime sleep opportunity improves the ability to correctly recognize face-name associations. Further studies investigating the mechanism of this improvement are important, as this finding has implications for individuals with sleep disturbances and/or memory impairments. PMID:26549626

  4. A new face of sleep: The impact of post-learning sleep on recognition memory for face-name associations.

    PubMed

    Maurer, Leonie; Zitting, Kirsi-Marja; Elliott, Kieran; Czeisler, Charles A; Ronda, Joseph M; Duffy, Jeanne F

    2015-12-01

    Sleep has been demonstrated to improve consolidation of many types of new memories. However, few prior studies have examined how sleep impacts learning of face-name associations. The recognition of a new face along with the associated name is an important human cognitive skill. Here we investigated whether post-presentation sleep impacts recognition memory of new face-name associations in healthy adults. Fourteen participants were tested twice. Each time, they were presented 20 photos of faces with a corresponding name. Twelve hours later, they were shown each face twice, once with the correct and once with an incorrect name, and asked if each face-name combination was correct and to rate their confidence. In one condition the 12-h interval between presentation and recall included an 8-h nighttime sleep opportunity ("Sleep"), while in the other condition they remained awake ("Wake"). There were more correct and highly confident correct responses when the interval between presentation and recall included a sleep opportunity, although improvement between the "Wake" and "Sleep" conditions was not related to duration of sleep or any sleep stage. These data suggest that a nighttime sleep opportunity improves the ability to correctly recognize face-name associations. Further studies investigating the mechanism of this improvement are important, as this finding has implications for individuals with sleep disturbances and/or memory impairments. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Predicting Long-term Temperature Increase for Time-Dependent SAR Levels with a Single Short-term Temperature Response

    PubMed Central

    Carluccio, Giuseppe; Bruno, Mary; Collins, Christopher M.

    2015-01-01

    Purpose Present a novel method for rapid prediction of temperature in vivo for a series of pulse sequences with differing levels and distributions of specific energy absorption rate (SAR). Methods After the temperature response to a brief period of heating is characterized, a rapid estimate of temperature during a series of periods at different heating levels is made using a linear heat equation and Impulse-Response (IR) concepts. Here the initial characterization and long-term prediction for a complete spine exam are made with the Pennes’ bioheat equation where, at first, core body temperature is allowed to increase and local perfusion is not. Then corrections through time allowing variation in local perfusion are introduced. Results The fast IR-based method predicted maximum temperature increase within 1% of that with a full finite difference simulation, but required less than 3.5% of the computation time. Even higher accelerations are possible depending on the time step size chosen, with loss in temporal resolution. Correction for temperature-dependent perfusion requires negligible additional time, and can be adjusted to be more or less conservative than the corresponding finite difference simulation. Conclusion With appropriate methods, it is possible to rapidly predict temperature increase throughout the body for actual MR examinations. (200/200 words) PMID:26096947

  6. Predicting long-term temperature increase for time-dependent SAR levels with a single short-term temperature response.

    PubMed

    Carluccio, Giuseppe; Bruno, Mary; Collins, Christopher M

    2016-05-01

    Present a novel method for rapid prediction of temperature in vivo for a series of pulse sequences with differing levels and distributions of specific energy absorption rate (SAR). After the temperature response to a brief period of heating is characterized, a rapid estimate of temperature during a series of periods at different heating levels is made using a linear heat equation and impulse-response (IR) concepts. Here the initial characterization and long-term prediction for a complete spine exam are made with the Pennes' bioheat equation where, at first, core body temperature is allowed to increase and local perfusion is not. Then corrections through time allowing variation in local perfusion are introduced. The fast IR-based method predicted maximum temperature increase within 1% of that with a full finite difference simulation, but required less than 3.5% of the computation time. Even higher accelerations are possible depending on the time step size chosen, with loss in temporal resolution. Correction for temperature-dependent perfusion requires negligible additional time and can be adjusted to be more or less conservative than the corresponding finite difference simulation. With appropriate methods, it is possible to rapidly predict temperature increase throughout the body for actual MR examinations. © 2015 Wiley Periodicals, Inc.

  7. Understanding Emotions in Frontotemporal Dementia: The Explicit and Implicit Emotional Cue Mismatch.

    PubMed

    Balconi, Michela; Cotelli, Maria; Brambilla, Michela; Manenti, Rosa; Cosseddu, Maura; Premi, Enrico; Gasparotti, Roberto; Zanetti, Orazio; Padovani, Alessandro; Borroni, Barbara

    2015-01-01

    Previous studies have reported significant deficits in emotion recognition among individuals along the frontotemporal dementia (FTD) spectrum. The basis of emotional impairment is still poorly understood and explicit (emotion appraisal) and implicit (autonomic system activity) responses have not been carefully evaluated. We investigated explicit evaluation of emotions by testing valence and arousal using self-report measures and we also assessed automatic responses to emotional cues, using autonomic measures (skin conductance response and heart rate). 16 behavioral variant FTD and 12 agrammatic variants of primary progressive aphasia patients were included. The performance of these patients was compared to a group of 14 patients with Alzheimer's disease and 20 healthy controls. Each subject was required to observe and evaluate affective pictures while autonomic parameters were recorded. FTD patients preserved a functional general competency in terms of valence (correct positive versus negative attribution) and arousal (correct dichotomy between high versus low arousal category) distinction. These patients showed significant changes in autonomic implicit response compared to the other groups. The mismatch between explicit and implicit responsiveness to emotional cues was found both in behavioral variant FTD and in agrammatic variants of primary progressive aphasia. Emotional responsiveness was related to the severity of behavioral abnormalities as measured by the Frontal Behavioral Inventory and associated with atrophy of the left putamen. The present findings indicate that FTD patients are able to explicitly "appraise" the emotion, but they cannot implicitly "feel" the emotion. This mismatch between the two levels may help explain the general emotional behavior impairment found in these patients.

  8. SU-F-T-584: Investigating Correction Methods for Ion Recombination Effects in OCTAVIUS 1000 SRS Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knill, C; Wayne State University School of Medicine, Detroit, MI; Snyder, M

    Purpose: PTW’s Octavius 1000 SRS array performs IMRT QA measurements with liquid filled ionization chambers (LICs). Collection efficiencies of LICs have been shown to change during IMRT delivery as a function of LINAC pulse frequency and pulse dose, which affects QA results. In this study, two methods were developed to correct changes in collection efficiencies during IMRT QA measurements, and the effects of these corrections on QA pass rates were compared. Methods: For the first correction, Matlab software was developed that calculates pulse frequency and pulse dose for each detector, using measurement and DICOM RT Plan files. Pulse information ismore » converted to collection efficiency and measurements are corrected by multiplying detector dose by ratios of calibration to measured collection efficiencies. For the second correction, MU/min in daily 1000 SRS calibration was chosen to match average MU/min of the VMAT plan. Usefulness of derived corrections were evaluated using 6MV and 10FFF SBRT RapidArc plans delivered to the OCTAVIUS 4D system using a TrueBeam equipped with an HD- MLC. Effects of the two corrections on QA results were examined by performing 3D gamma analysis comparing predicted to measured dose, with and without corrections. Results: After complex Matlab corrections, average 3D gamma pass rates improved by [0.07%,0.40%,1.17%] for 6MV and [0.29%,1.40%,4.57%] for 10FFF using [3%/3mm,2%/2mm,1%/1mm] criteria. Maximum changes in gamma pass rates were [0.43%,1.63%,3.05%] for 6MV and [1.00%,4.80%,11.2%] for 10FFF using [3%/3mm,2%/2mm,1%/1mm] criteria. On average, pass rates of simple daily calibration corrections were within 1% of complex Matlab corrections. Conclusion: Ion recombination effects can potentially be clinically significant for OCTAVIUS 1000 SRS measurements, especially for higher pulse dose unflattened beams when using tighter gamma tolerances. Matching daily 1000 SRS calibration MU/min to average planned MU/min is a simple correction that greatly reduces ion recombination effects, improving measurements accuracy and gamma pass rates. This work was supported by PTW.« less

  9. Graphical representation of QT rate correction formulae: an aid facilitating the use of a given formula and providing a visual comparison of the impact of different formulae.

    PubMed

    Rowlands, Derek J

    2012-01-01

    The QT interval on the electrocardiogram is an increasingly important measurement, especially in relation to drug action and interaction. The QT interval varies inversely as the heart rate and numerous rate correction formulae have been proposed. It is difficult to compare the effect of applying different formulae at different heart rates and for different measured QT intervals. A simple graphical display of the results from different formulae is proposed. This display is dependent on the concept of the absolute correction factor. This graphical presentation is useful (a) in comparing the effect of the application of different formulae and (b) in directly reading the correction produced by any individual formula. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. The Impact of Traumatic Brain Injury on Prison Health Services and Offender Management.

    PubMed

    Piccolino, Adam L; Solberg, Kenneth B

    2014-07-01

    A large percentage of incarcerated offenders report a history of traumatic brain injury (TBI) with concomitant neuropsychiatric and social sequelae. However, research looking at the relationship between TBI and delivery of correctional health services and offender management is limited. In this study, the relationships between TBI and use of correctional medical/psychological services, chemical dependency (CD) treatment completion rates, in-prison rule infractions, and recidivism were investigated. Findings indicated that TBI history has a statistically significant association with increased usage of correctional medical/psychological services, including crisis interventions services, and with higher recidivism rates. Results also showed a trend toward offenders with TBI incurring higher rates of in-prison rule infractions and lower rates of CD treatment completion. Implications and future directions for correctional systems are discussed. © The Author(s) 2014.

  11. Use of a Self-Instructional Radiographic Anatomy Module for Dental Hygiene Faculty Calibration.

    PubMed

    Brame, Jennifer L; AlGheithy, Demah Salem; Platin, Enrique; Mitchell, Shannon H

    2017-06-01

    Purpose: Dental hygiene educators often provide inconsistent instruction in clinical settings and various attempts to address the lack of consistency have been reported in the literature. The purpose of this pilot study was to determine if the use of a use of a self-instructional, radiographic anatomy (SIRA) module improved DH faculty calibration regarding the identifica-tion of normal intraoral and extraoral radiographic anatomy and whether its effect could be sustained over a period of four months. Methods: A convenience sample consisting of all dental hygiene faculty members involved in clinical instruction (N=23) at the University of North Carolina (UNC) was invited to complete the four parts of this online pilot study: a pre-test, review of the SIRA module, an immediate post-test, and a four-month follow-up post-test. Descriptive analyses, the Friedman's ANOVA, and the exact form of the Wilcoxon-Signed-Rank test were used to an-alyze the data. Level of significance was set at 0.05. Participants who did not complete all parts of the study were omitted from data analysis comparing the pre to post-test performance. Results: The pre-test response rate was 73.9% (N=17), and 88.2% (N=15) of those initial participants completed both the immediate and follow-up post-tests. Faculty completing all parts of the study consisted of: 5 full-time faculty, 5 part-time faculty, and 5 graduate teaching assistants. The Friedman's ANOVA revealed no statistically significant difference (P=0.179) in percentages of correct responses between the three tests (pre, post and follow-up). The exact form of the Wilcoxon-Signed-Rank test revealed marginal significance when comparing percent of correct responses at pre-test and immediate post-test (P=0.054), and no statistically significant difference when comparing percent of correct responses at immediate post-test and the follow-up post-test four months later (P=0.106). Conclusions: Use of a SIRA module did not significantly affect DH faculty test performance. Lack of statistical significance in the percentages of correct responses between the three tests may have been affected by the small number of participants completing all four parts of the study (N=15). Additional research is needed to identify and improve methods for faculty calibration. Copyright © 2017 The American Dental Hygienists’ Association.

  12. Caliber Corrected Markov Modeling (C2M2): Correcting Equilibrium Markov Models.

    PubMed

    Dixit, Purushottam D; Dill, Ken A

    2018-02-13

    Rate processes are often modeled using Markov State Models (MSMs). Suppose you know a prior MSM and then learn that your prediction of some particular observable rate is wrong. What is the best way to correct the whole MSM? For example, molecular dynamics simulations of protein folding may sample many microstates, possibly giving correct pathways through them while also giving the wrong overall folding rate when compared to experiment. Here, we describe Caliber Corrected Markov Modeling (C 2 M 2 ), an approach based on the principle of maximum entropy for updating a Markov model by imposing state- and trajectory-based constraints. We show that such corrections are equivalent to asserting position-dependent diffusion coefficients in continuous-time continuous-space Markov processes modeled by a Smoluchowski equation. We derive the functional form of the diffusion coefficient explicitly in terms of the trajectory-based constraints. We illustrate with examples of 2D particle diffusion and an overdamped harmonic oscillator.

  13. FREQUENCY STABILIZING SYSTEM

    DOEpatents

    Kerns, Q.A.; Anderson, O.A.

    1960-05-01

    An electronic control circuit is described in which a first signal frequency is held in synchronization with a second varying reference signal. The circuit receives the first and second signals as inputs and produces an output signal having an amplitude dependent upon rate of phase change between the two signals and a polarity dependent on direction of the phase change. The output may thus serve as a correction signal for maintaining the desired synchronization. The response of the system is not dependent on relative phase angle between the two compared signals. By having practically no capacitance in the circuit, there is minimum delay between occurrence of a phase shift and a response in the output signal and therefore very fast synchronization is effected.

  14. Advantages of estimating rate corrections during dynamic propagation of spacecraft rates: Applications to real-time attitude determination of SAMPEX

    NASA Technical Reports Server (NTRS)

    Challa, M. S.; Natanson, G. A.; Baker, D. F.; Deutschmann, J. K.

    1994-01-01

    This paper describes real-time attitude determination results for the Solar, Anomalous, and Magnetospheric Particle Explorer (SAMPEX), a gyroless spacecraft, using a Kalman filter/Euler equation approach denoted the real-time sequential filter (RTSF). The RTSF is an extended Kalman filter whose state vector includes the attitude quaternion and corrections to the rates, which are modeled as Markov processes with small time constants. The rate corrections impart a significant robustness to the RTSF against errors in modeling the environmental and control torques, as well as errors in the initial attitude and rates, while maintaining a small state vector. SAMPLEX flight data from various mission phases are used to demonstrate the robustness of the RTSF against a priori attitude and rate errors of up to 90 deg and 0.5 deg/sec, respectively, as well as a sensitivity of 0.0003 deg/sec in estimating rate corrections in torque computations. In contrast, it is shown that the RTSF attitude estimates without the rate corrections can degrade rapidly. RTSF advantages over single-frame attitude determination algorithms are also demonstrated through (1) substantial improvements in attitude solutions during sun-magnetic field coalignment and (2) magnetic-field-only attitude and rate estimation during the spacecraft's sun-acquisition mode. A robust magnetometer-only attitude-and-rate determination method is also developed to provide for the contingency when both sun data as well as a priori knowledge of the spacecraft state are unavailable. This method includes a deterministic algorithm used to initialize the RTSF with coarse estimates of the spacecraft attitude and rates. The combined algorithm has been found effective, yielding accuracies of 1.5 deg in attitude and 0.01 deg/sec in the rates and convergence times as little as 400 sec.

  15. Advanced electronics for the CTF MEG system.

    PubMed

    McCubbin, J; Vrba, J; Spear, P; McKenzie, D; Willis, R; Loewen, R; Robinson, S E; Fife, A A

    2004-11-30

    Development of the CTF MEG system has been advanced with the introduction of a computer processing cluster between the data acquisition electronics and the host computer. The advent of fast processors, memory, and network interfaces has made this innovation feasible for large data streams at high sampling rates. We have implemented tasks including anti-alias filter, sample rate decimation, higher gradient balancing, crosstalk correction, and optional filters with a cluster consisting of 4 dual Intel Xeon processors operating on up to 275 channel MEG systems at 12 kHz sample rate. The architecture is expandable with additional processors to implement advanced processing tasks which may include e.g., continuous head localization/motion correction, optional display filters, coherence calculations, or real time synthetic channels (via beamformer). We also describe an electronics configuration upgrade to provide operator console access to the peripheral interface features such as analog signal and trigger I/O. This allows remote location of the acoustically noisy electronics cabinet and fitting of the cabinet with doors for improved EMI shielding. Finally, we present the latest performance results available for the CTF 275 channel MEG system including an unshielded SEF (median nerve electrical stimulation) measurement enhanced by application of an adaptive beamformer technique (SAM) which allows recognition of the nominal 20-ms response in the unaveraged signal.

  16. On artifacts in single-molecule force spectroscopy

    PubMed Central

    Cossio, Pilar; Hummer, Gerhard; Szabo, Attila

    2015-01-01

    In typical force spectroscopy experiments, a small biomolecule is attached to a soft polymer linker that is pulled with a relatively large bead or cantilever. At constant force, the total extension stochastically changes between two (or more) values, indicating that the biomolecule undergoes transitions between two (or several) conformational states. In this paper, we consider the influence of the dynamics of the linker and mesoscopic pulling device on the force-dependent rate of the conformational transition extracted from the time dependence of the total extension, and the distribution of rupture forces in force-clamp and force-ramp experiments, respectively. For these different experiments, we derive analytic expressions for the observables that account for the mechanical response and dynamics of the pulling device and linker. Possible artifacts arise when the characteristic times of the pulling device and linker become comparable to, or slower than, the lifetimes of the metastable conformational states, and when the highly anharmonic regime of stretched linkers is probed at high forces. We also revisit the problem of relating force-clamp and force-ramp experiments, and identify a linker and loading rate-dependent correction to the rates extracted from the latter. The theory provides a framework for both the design and the quantitative analysis of force spectroscopy experiments by highlighting, and correcting for, factors that complicate their interpretation. PMID:26540730

  17. A model-independent comparison of the rates of uptake and short term retention of 47Ca and 85Sr by the skeleton.

    PubMed

    Reeve, J; Hesp, R

    1976-12-22

    1. A method has been devised for comparing the impulse response functions of the skeleton for two or more boneseeking tracers, and for estimating the contribution made by measurement errors to the differences between any pair of impulse response functions. 2. Comparisons were made between the calculated impulse response functions for 47Ca and 85Sr obtained in simultaneous double tracer studies in sixteen subjects. Collectively the differences between the 47Ca and 85Sr functions could be accounted for entirely by measurement errors. 3. Because the calculation of an impulse response function requires fewer a priori assumptions than other forms of mathematical analysis, and automatically corrects for differences induced by recycling of tracer and non-identical rates of excretory plasma clearance of tracer, it is concluded that differences shown in previous in vivo studies between the fluxes of Ca and Sr into bone can be fully accounted for by undetermined oversimplifications in the various mathematical models used to analyse the results of those studies. 85Sr is therefore an adequate tracer for bone calcium in most in vivo studies.

  18. Intended actions and unexpected outcomes: automatic and controlled processing in a rapid motor task

    PubMed Central

    Cheyne, Douglas O.; Ferrari, Paul; Cheyne, James A.

    2012-01-01

    Human action involves a combination of controlled and automatic behavior. These processes may interact in tasks requiring rapid response selection or inhibition, where temporal constraints preclude timely intervention by conscious, controlled processes over automatized prepotent responses. Such contexts tend to produce frequent errors, but also rapidly executed correct responses, both of which may sometimes be perceived as surprising, unintended, or “automatic”. In order to identify neural processes underlying these two aspects of cognitive control, we measured neuromagnetic brain activity in 12 right-handed subjects during manual responses to rapidly presented digits, with an infrequent target digit that required switching response hand (bimanual task) or response finger (unimanual task). Automaticity of responding was evidenced by response speeding (shorter response times) prior to both failed and fast correct switches. Consistent with this automaticity interpretation of fast correct switches, we observed bilateral motor preparation, as indexed by suppression of beta band (15–30 Hz) oscillations in motor cortex, prior to processing of the switch cue in the bimanual task. In contrast, right frontal theta activity (4–8 Hz) accompanying correct switch responses began after cue onset, suggesting that it reflected controlled inhibition of the default response. Further, this activity was reduced on fast correct switch trials suggesting a more automatic mode of inhibitory control. We also observed post-movement (event-related negativity) ERN-like responses and theta band increases in medial and anterior frontal regions that were significantly larger on error trials, and may reflect a combination of error and delayed inhibitory signals. We conclude that both automatic and controlled processes are engaged in parallel during rapid motor tasks, and that the relative strength and timing of these processes may underlie both optimal task performance and subjective experiences of automaticity or control. PMID:22912612

  19. A New Approach for Determining Phase Response Curves Reveals that Purkinje Cells Can Act as Perfect Integrators

    PubMed Central

    Roth, Arnd; Häusser, Michael

    2010-01-01

    Cerebellar Purkinje cells display complex intrinsic dynamics. They fire spontaneously, exhibit bistability, and via mutual network interactions are involved in the generation of high frequency oscillations and travelling waves of activity. To probe the dynamical properties of Purkinje cells we measured their phase response curves (PRCs). PRCs quantify the change in spike phase caused by a stimulus as a function of its temporal position within the interspike interval, and are widely used to predict neuronal responses to more complex stimulus patterns. Significant variability in the interspike interval during spontaneous firing can lead to PRCs with a low signal-to-noise ratio, requiring averaging over thousands of trials. We show using electrophysiological experiments and simulations that the PRC calculated in the traditional way by sampling the interspike interval with brief current pulses is biased. We introduce a corrected approach for calculating PRCs which eliminates this bias. Using our new approach, we show that Purkinje cell PRCs change qualitatively depending on the firing frequency of the cell. At high firing rates, Purkinje cells exhibit single-peaked, or monophasic PRCs. Surprisingly, at low firing rates, Purkinje cell PRCs are largely independent of phase, resembling PRCs of ideal non-leaky integrate-and-fire neurons. These results indicate that Purkinje cells can act as perfect integrators at low firing rates, and that the integration mode of Purkinje cells depends on their firing rate. PMID:20442875

  20. Cortisol, Chromogranin A, and Pupillary Responses Evoked by Speech Recognition Tasks in Normally Hearing and Hard-of-Hearing Listeners: A Pilot Study.

    PubMed

    Kramer, Sophia E; Teunissen, Charlotte E; Zekveld, Adriana A

    2016-01-01

    Pupillometry is one method that has been used to measure processing load expended during speech understanding. Notably, speech perception (in noise) tasks can evoke a pupil response. It is not known if there is concurrent activation of the sympathetic nervous system as indexed by salivary cortisol and chromogranin A (CgA) and whether such activation differs between normally hearing (NH) and hard-of-hearing (HH) adults. Ten NH and 10 adults with mild-to-moderate hearing loss (mean age 52 years) participated. Two speech perception tests were administered in random order: one in quiet targeting 100% correct performance and one in noise targeting 50% correct performance. Pupil responses and salivary samples for cortisol and CgA analyses were collected four times: before testing, after the two speech perception tests, and at the end of the session. Participants rated their perceived accuracy, effort, and motivation. Effects were examined using repeated-measures analyses of variance. Correlations between outcomes were calculated. HH listeners had smaller peak pupil dilations (PPDs) than NH listeners in the speech in noise condition only. No group or condition effects were observed for the cortisol data, but HH listeners tended to have higher cortisol levels across conditions. CgA levels were larger at the pretesting time than at the three other test times. Hearing impairment did not affect CgA. Self-rated motivation correlated most often with cortisol or PPD values. The three physiological indicators of cognitive load and stress (PPD, cortisol, and CgA) are not equally affected by speech testing or hearing impairment. Each of them seem to capture a different dimension of sympathetic nervous system activity.

  1. Assessment of knowledge and attitudes of dental students in regard to child abuse in Turkey.

    PubMed

    Hazar Bodrumlu, E; Avşar, A; Arslan, S

    2018-02-01

    Child abuse is a serious public problem. Signs of abuse are often present in the oro-facial region and dentists are in a strategic position to recognise and report suspected cases. The aim of this study was to investigate dental students' knowledge about and attitudes towards child abuse. This study was performed at the Faculty of Dentistry of the Ondokuz Mayis University. The data were collected through a self-report questionnaire administered to dental students (137 female/111 male) in three different dental classes (third, fourth and fifth study years) and grouped by considering those students who have been training in the school year of 2013. The definition of physical and social indicators of abuse, awareness regarding legal and ethical responsibilities, students' experience and requests made by students were evaluated by the students' response to questions put in the questionnaire. Descriptive statistics and chi-square tests were performed to analyse the questionnaire data. The questionnaire completion rate was 100%. About 67.74% of the third year, 40.71% of the fourth year and 16.67% of the fifth year believed that they could detect child abuse cases. However, results indicated a major lack of knowledge of social indicators, signs of physical abuse and reporting procedure amongst all respondents. The assessment of the total correct answers exhibited significant differences amongst third-, fourth- and fifth-year students' answers. Fifth-year students had the highest rate of correct responses (P < 0.05). Most students wanted to receive more knowledge about this topic. Dental students in Turkey are not sufficiently prepared for their role in diagnosing suspected cases of child abuse. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. The effect of divided attention on novices and experts in laparoscopic task performance.

    PubMed

    Ghazanfar, Mudassar Ali; Cook, Malcolm; Tang, Benjie; Tait, Iain; Alijani, Afshin

    2015-03-01

    Attention is important for the skilful execution of surgery. The surgeon's attention during surgery is divided between surgery and outside distractions. The effect of this divided attention has not been well studied previously. We aimed to compare the effect of dividing attention of novices and experts on a laparoscopic task performance. Following ethical approval, 25 novices and 9 expert surgeons performed a standardised peg transfer task in a laboratory setup under three randomly assigned conditions: silent as control condition and two standardised auditory distracting tasks requiring response (easy and difficult) as study conditions. Human reliability assessment was used for surgical task analysis. Primary outcome measures were correct auditory responses, task time, number of surgical errors and instrument movements. Secondary outcome measures included error rate, error probability and hand specific differences. Non-parametric statistics were used for data analysis. 21109 movements and 9036 total errors were analysed. Novices had increased mean task completion time (seconds) (171 ± 44SD vs. 149 ± 34, p < 0.05), number of total movements (227 ± 27 vs. 213 ± 26, p < 0.05) and number of errors (127 ± 51 vs. 96 ± 28, p < 0.05) during difficult study conditions compared to control. The correct responses to auditory stimuli were less frequent in experts (68 %) compared to novices (80 %). There was a positive correlation between error rate and error probability in novices (r (2) = 0.533, p < 0.05) but not in experts (r (2) = 0.346, p > 0.05). Divided attention conditions in theatre environment require careful consideration during surgical training as the junior surgeons are less able to focus their attention during these conditions.

  3. Cognitive Control Functions of Anterior Cingulate Cortex in Macaque Monkeys Performing a Wisconsin Card Sorting Test Analog

    PubMed Central

    Kuwabara, Masaru; Mansouri, Farshad A.; Buckley, Mark J.

    2014-01-01

    Monkeys were trained to select one of three targets by matching in color or matching in shape to a sample. Because the matching rule frequently changed and there were no cues for the currently relevant rule, monkeys had to maintain the relevant rule in working memory to select the correct target. We found that monkeys' error commission was not limited to the period after the rule change and occasionally occurred even after several consecutive correct trials, indicating that the task was cognitively demanding. In trials immediately after such error trials, monkeys' speed of selecting targets was slower. Additionally, in trials following consecutive correct trials, the monkeys' target selections for erroneous responses were slower than those for correct responses. We further found evidence for the involvement of the cortex in the anterior cingulate sulcus (ACCs) in these error-related behavioral modulations. First, ACCs cell activity differed between after-error and after-correct trials. In another group of ACCs cells, the activity differed depending on whether the monkeys were making a correct or erroneous decision in target selection. Second, bilateral ACCs lesions significantly abolished the response slowing both in after-error trials and in error trials. The error likelihood in after-error trials could be inferred by the error feedback in the previous trial, whereas the likelihood of erroneous responses after consecutive correct trials could be monitored only internally. These results suggest that ACCs represent both context-dependent and internally detected error likelihoods and promote modes of response selections in situations that involve these two types of error likelihood. PMID:24872558

  4. Servo control booster system for minimizing following error

    DOEpatents

    Wise, William L.

    1985-01-01

    A closed-loop feedback-controlled servo system is disclosed which reduces command-to-response error to the system's position feedback resolution least increment, .DELTA.S.sub.R, on a continuous real-time basis for all operating speeds. The servo system employs a second position feedback control loop on a by exception basis, when the command-to-response error .gtoreq..DELTA.S.sub.R, to produce precise position correction signals. When the command-to-response error is less than .DELTA.S.sub.R, control automatically reverts to conventional control means as the second position feedback control loop is disconnected, becoming transparent to conventional servo control means. By operating the second unique position feedback control loop used herein at the appropriate clocking rate, command-to-response error may be reduced to the position feedback resolution least increment. The present system may be utilized in combination with a tachometer loop for increased stability.

  5. Modifying Speech to Children based on their Perceived Phonetic Accuracy

    PubMed Central

    Julien, Hannah M.; Munson, Benjamin

    2014-01-01

    Purpose We examined the relationship between adults' perception of the accuracy of children's speech, and acoustic detail in their subsequent productions to children. Methods Twenty-two adults participated in a task in which they rated the accuracy of 2- and 3-year-old children's word-initial /s/and /∫/ using a visual analog scale (VAS), then produced a token of the same word as if they were responding to the child whose speech they had just rated. Result The duration of adults' fricatives varied as a function of their perception of the accuracy of children's speech: longer fricatives were produced following productions that they rated as inaccurate. This tendency to modify duration in response to perceived inaccurate tokens was mediated by measures of self-reported experience interacting with children. However, speakers did not increase the spectral distinctiveness of their fricatives following the perception of inaccurate tokens. Conclusion These results suggest that adults modify temporal features of their speech in response to perceiving children's inaccurate productions. These longer fricatives are potentially both enhanced input to children, and an error-corrective signal. PMID:22744140

  6. Contingency Learning and Reactivity in Preterm and Full-Term Infants at 3 Months

    PubMed Central

    Haley, David W.; Grunau, Ruth E.; Oberlander, Tim F.; Weinberg, Joanne

    2010-01-01

    Learning difficulties in preterm infants are thought to reflect impairment in arousal regulation. We examined relationships among gestational age, learning speed, and behavioral and physiological reactivity in 55 preterm and 49 full-term infants during baseline, contingency, and nonreinforcement phases of a conjugate mobile paradigm at 3 months corrected age. For all infants, negative affect, looking duration, and heart rate levels increased during contingency and nonreinforcement phases, whereas respiratory sinus arrhythmia (RSA, an index of parasympathetic activity) decreased and cortisol did not change. Learners showed greater RSA suppression and less negative affect than nonlearners. This pattern was particularly evident in the preterm group. Overall, preterm infants showed less learning, spent less time looking at the mobile, and had lower cortisol levels than full-term infants. Preterm infants also showed greater heart rate responses to contingency and dampened heart rate responses to nonreinforcement compared to full-term infants. Findings underscore differences in basal and reactivity measures in preterm compared to full-term infants and suggest that the capacity to regulate parasympathetic activity during a challenge enhances learning in preterm infants. PMID:20717491

  7. Photosynthetic Acclimation of Symbiodinium in hospite Depends on Vertical Position in the Tissue of the Scleractinian Coral Montastrea curta

    PubMed Central

    Lichtenberg, Mads; Larkum, Anthony W. D.; Kühl, Michael

    2016-01-01

    Coral photophysiology has been studied intensively from the colony scale down to the scale of single fluorescent pigment granules as light is one of the key determinants for coral health. We studied the photophysiology of the oral and aboral symbiont band of scleractinian coral Montastrea curta to investigate if different acclimation to light exist in hospite on a polyp scale. By combined use of electrochemical and fiber-optic microsensors for O2, scalar irradiance and variable chlorophyll fluorescence, we could characterize the physical and chemical microenvironment experienced by the symbionts and, for the first time, estimate effective quantum yields of PSII photochemistry and rates of electron transport at the position of the zooxanthellae corrected for the in-tissue gradient of scalar irradiance. The oral- and aboral Symbiodinium layers received ∼71% and ∼33% of surface scalar irradiance, respectively, and the two symbiont layers experience considerable differences in light exposure. Rates of gross photosynthesis did not differ markedly between the oral- and aboral layer and curves of PSII electron transport rates corrected for scalar irradiance in hospite, showed that the light use efficiency under sub-saturating light conditions were similar between the two layers. However, the aboral Symbiodinium band did not experience photosynthetic saturation, even at the highest investigated irradiance where the oral layer was clearly saturated. We thus found a different light acclimation response for the oral and aboral symbiont bands in hospite, and discuss whether such response could be shaped by spectral shifts caused by tissue gradients of scalar irradiance. Based on our experimental finding, combined with previous knowledge, we present a conceptual model on the photophysiology of Symbiodinium residing inside living coral tissue under natural gradients of light and chemical parameters. PMID:26955372

  8. Photosynthetic Acclimation of Symbiodinium in hospite Depends on Vertical Position in the Tissue of the Scleractinian Coral Montastrea curta.

    PubMed

    Lichtenberg, Mads; Larkum, Anthony W D; Kühl, Michael

    2016-01-01

    Coral photophysiology has been studied intensively from the colony scale down to the scale of single fluorescent pigment granules as light is one of the key determinants for coral health. We studied the photophysiology of the oral and aboral symbiont band of scleractinian coral Montastrea curta to investigate if different acclimation to light exist in hospite on a polyp scale. By combined use of electrochemical and fiber-optic microsensors for O2, scalar irradiance and variable chlorophyll fluorescence, we could characterize the physical and chemical microenvironment experienced by the symbionts and, for the first time, estimate effective quantum yields of PSII photochemistry and rates of electron transport at the position of the zooxanthellae corrected for the in-tissue gradient of scalar irradiance. The oral- and aboral Symbiodinium layers received ∼71% and ∼33% of surface scalar irradiance, respectively, and the two symbiont layers experience considerable differences in light exposure. Rates of gross photosynthesis did not differ markedly between the oral- and aboral layer and curves of PSII electron transport rates corrected for scalar irradiance in hospite, showed that the light use efficiency under sub-saturating light conditions were similar between the two layers. However, the aboral Symbiodinium band did not experience photosynthetic saturation, even at the highest investigated irradiance where the oral layer was clearly saturated. We thus found a different light acclimation response for the oral and aboral symbiont bands in hospite, and discuss whether such response could be shaped by spectral shifts caused by tissue gradients of scalar irradiance. Based on our experimental finding, combined with previous knowledge, we present a conceptual model on the photophysiology of Symbiodinium residing inside living coral tissue under natural gradients of light and chemical parameters.

  9. Bunch mode specific rate corrections for PILATUS3 detectors

    DOE PAGES

    Trueb, P.; Dejoie, C.; Kobas, M.; ...

    2015-04-09

    PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanismmore » has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.« less

  10. Applying cognitive acuity theory to the development and scoring of situational judgment tests.

    PubMed

    Leeds, J Peter

    2017-11-09

    The theory of cognitive acuity (TCA) treats the response options within items as signals to be detected and uses psychophysical methods to estimate the respondents' sensitivity to these signals. Such a framework offers new methods to construct and score situational judgment tests (SJT). Leeds (2012) defined cognitive acuity as the capacity to discern correctness and distinguish between correctness differences among simultaneously presented situation-specific response options. In this study, SJT response options were paired in order to offer the respondent a two-option choice. The contrast in correctness valence between the two options determined the magnitude of signal emission, with larger signals portending a higher probability of detection. A logarithmic relation was found between correctness valence contrast (signal stimulus) and its detectability (sensation response). Respondent sensitivity to such signals was measured and found to be related to the criterion variables. The linkage between psychophysics and elemental psychometrics may offer new directions for measurement theory.

  11. Testing Moderating Detection Systems with {sup 252}Cf-Based Reference Neutron Fields

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hertel, Nolan E.; Sweezy, Jeremy; Sauber, Jeremiah S.

    Calibration measurements were carried out on a probe designed to measure ambient dose equivalent in accordance with ICRP Pub 60 recommendations. It consists of a cylindrical {sup 3}He proportional counter surrounded by a 25-cm-diameter spherical polyethylene moderator. Its neutron response is optimized for dose rate measurements of neutrons between thermal energies and 20 MeV. The instrument was used to measure the dose rate in four separate neutron fields: unmoderated {sup 252}Cf, D{sub 2}O-moderated {sup 252}Cf, polyethylene-moderated {sup 252}Cf, and WEP neutron howitzer with {sup 252}Cf at its center. Dose equivalent measurements were performed at source-detector centerline distances from 50 tomore » 200 cm. The ratio of air-scatter- and room-return-corrected ambient dose equivalent rates to ambient dose equivalent rates calculated with the code MCNP are tabulated.« less

  12. Can corrective feedback improve recognition memory?

    PubMed

    Kantner, Justin; Lindsay, D Stephen

    2010-06-01

    An understanding of the effects of corrective feedback on recognition memory can inform both recognition theory and memory training programs, but few published studies have investigated the issue. Although the evidence to date suggests that feedback does not improve recognition accuracy, few studies have directly examined its effect on sensitivity, and fewer have created conditions that facilitate a feedback advantage by encouraging controlled processing at test. In Experiment 1, null effects of feedback were observed following both deep and shallow encoding of categorized study lists. In Experiment 2, feedback robustly influenced response bias by allowing participants to discern highly uneven base rates of old and new items, but sensitivity remained unaffected. In Experiment 3, a false-memory procedure, feedback failed to attenuate false recognition of critical lures. In Experiment 4, participants were unable to use feedback to learn a simple category rule separating old items from new items, despite the fact that feedback was of substantial benefit in a nearly identical categorization task. The recognition system, despite a documented ability to utilize controlled strategic or inferential decision-making processes, appears largely impenetrable to a benefit of corrective feedback.

  13. MEMS Reaction Control and Maneuvering for Picosat Beyond LEO

    NASA Technical Reports Server (NTRS)

    Alexeenko, Alina

    2016-01-01

    The MEMS Reaction Control and Maneuvering for Picosat Beyond LEO project will further develop a multi-functional small satellite technology for low-power attitude control, or orientation, of picosatellites beyond low Earth orbit (LEO). The Film-Evaporation MEMS Tunable Array (FEMTA) concept initially developed in 2013, is a thermal valving system which utilizes capillary forces in a microchannel to offset internal pressures in a bulk fluid. The local vapor pressure is increased by resistive film heating until it exceeds meniscus strength in a nozzle which induces vacuum boiling and provides a stagnation pressure equal to vapor pressure at that point which is used for propulsion. Interplanetary CubeSats can utilize FEMTA for high slew rate attitude corrections in addition to desaturating reaction wheels. The FEMTA in cooling mode can be used for thermal control during high-power communication events, which are likely to accompany the attitude correction. Current small satellite propulsion options are limited to orbit correction whereas picosatellites are lacking attitude control thrusters. The available attitude control systems are either quickly saturated reaction wheels or movable high drag surfaces with long response times.

  14. Application of a Novel S3 Nanowire Gas Sensor Device in Parallel with GC-MS for the Identification of Rind Percentage of Grated Parmigiano Reggiano.

    PubMed

    Abbatangelo, Marco; Núñez-Carmona, Estefanía; Sberveglieri, Veronica; Zappa, Dario; Comini, Elisabetta; Sberveglieri, Giorgio

    2018-05-18

    Parmigiano Reggiano cheese is one of the most appreciated and consumed foods worldwide, especially in Italy, for its high content of nutrients and taste. However, these characteristics make this product subject to counterfeiting in different forms. In this study, a novel method based on an electronic nose has been developed to investigate the potentiality of this tool to distinguish rind percentages in grated Parmigiano Reggiano packages that should be lower than 18%. Different samples, in terms of percentage, seasoning and rind working process, were considered to tackle the problem at 360°. In parallel, GC-MS technique was used to give a name to the compounds that characterize Parmigiano and to relate them to sensors responses. Data analysis consisted of two stages: Multivariate analysis (PLS) and classification made in a hierarchical way with PLS-DA ad ANNs. Results were promising, in terms of correct classification of the samples. The correct classification rate (%) was higher for ANNs than PLS-DA, with correct identification approaching 100 percent.

  15. Evaluation of Al2O3:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy.

    PubMed

    Yukihara, E G; Mardirossian, G; Mirzasadeghi, M; Guduru, S; Ahmad, S

    2008-01-01

    This article investigates the performance of Al2O3: C optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central-axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and 18 MV photons, and for 6, 9, 12, 16, and 20 MeV electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within +/- 1% for photon beams. Similar results were obtained for electron beams in the low-gradient region after correction for a 1.9% photon-to-electron bias. The distance-to-agreement values were of the order of 0.5-1.0 mm for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for 18 MV was (0.51 +/- 0.48)% of the response for the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at dmax within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.

  16. Evaluation of Al{sub 2}O{sub 3}:C optically stimulated luminescence (OSL) dosimeters for passive dosimetry of high-energy photon and electron beams in radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yukihara, E. G.; Mardirossian, G.; Mirzasadeghi, M.

    This article investigates the performance of Al{sub 2}O{sub 3}:C optically stimulated luminescence dosimeters (OSLDs) for application in radiotherapy. Central-axis depth dose curves and optically stimulated luminescence (OSL) responses were obtained in a water phantom for 6 and 18 MV photons, and for 6, 9, 12, 16, and 20 MeV electron beams from a Varian 21EX linear accelerator. Single OSL measurements could be repeated with a precision of 0.7% (one standard deviation) and the differences between absorbed doses measured with OSLDs and an ionization chamber were within {+-}1% for photon beams. Similar results were obtained for electron beams in the low-gradientmore » region after correction for a 1.9% photon-to-electron bias. The distance-to-agreement values were of the order of 0.5-1.0 mm for electrons in high dose gradient regions. Additional investigations also demonstrated that the OSL response dependence on dose rate, field size, and irradiation temperature is less than 1% in the conditions of the present study. Regarding the beam energy/quality dependence, the relative response of the OSLD for 18 MV was (0.51{+-}0.48)% of the response for the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam. The OSLD response for the electron beams relative to the 6 MV photon beam was in average 1.9% higher, but this result requires further confirmation. The relative response did not seem to vary with electron energy at d{sub max} within the experimental uncertainties (0.5% in average) and, therefore, a fixed correction factor of 1.9% eliminated the energy dependence in our experimental conditions.« less

  17. A pilot study regarding basic knowledge of "cortical visual impairment in children" among ophthalmologists.

    PubMed

    Maitreya, Amit; Rawat, Darshika; Pandey, Shubham

    2018-02-01

    A pilot study was done to evaluate knowledge regarding "cortical visual impairment (CVI) in children" among ophthalmologists. This study was conducted during the annual conference of a zonal ophthalmological society. All ophthalmologists who attended the conference were requested to participate in this study. Those who agreed were given a validated questionnaire to assess knowledge regarding CVI. Cronbach's alpha of the questionnaire was 0.6. Participants were asked to respond to multiple choice questions by choosing the single best option. The responses obtained were then evaluated. The total number of registered delegates in the conference was 448. A total of 103 ophthalmologists showed interest to participate in the study with a response rate of 22.9%. Only 89/103 interested delegates were included in the study as remaining were unaware of CVI. No participant gave correct answers to all questions. Although more than 80% of them knew the most common association (87%) and site of pathology (84%), only 52% were sure about clinical features and even lesser respondents (39%) knew that magnetic resonance imaging is the correct investigation of choice. The majority responded correctly that these children need eye examination (89%) and can be managed by rehabilitation through multidisciplinary approach (82%), but only 58% could recognize differential diagnoses and had a correct idea regarding the prognosis of CVI. There was no correlation between the number of patients diagnosed per month by the respondent with knowledge of the disease. In this pilot study, ophthalmologists were found to have limited knowledge regarding clinical features, investigation, differential diagnosis, and visual prognosis of CVI in children. There is a need to improve awareness regarding CVI among ophthalmologists.

  18. A pilot study regarding basic knowledge of “cortical visual impairment in children” among ophthalmologists

    PubMed Central

    Maitreya, Amit; Rawat, Darshika; Pandey, Shubham

    2018-01-01

    Purpose: A pilot study was done to evaluate knowledge regarding “cortical visual impairment (CVI) in children” among ophthalmologists. Methods: This study was conducted during the annual conference of a zonal ophthalmological society. All ophthalmologists who attended the conference were requested to participate in this study. Those who agreed were given a validated questionnaire to assess knowledge regarding CVI. Cronbach's alpha of the questionnaire was 0.6. Participants were asked to respond to multiple choice questions by choosing the single best option. The responses obtained were then evaluated. Results: The total number of registered delegates in the conference was 448. A total of 103 ophthalmologists showed interest to participate in the study with a response rate of 22.9%. Only 89/103 interested delegates were included in the study as remaining were unaware of CVI. No participant gave correct answers to all questions. Although more than 80% of them knew the most common association (87%) and site of pathology (84%), only 52% were sure about clinical features and even lesser respondents (39%) knew that magnetic resonance imaging is the correct investigation of choice. The majority responded correctly that these children need eye examination (89%) and can be managed by rehabilitation through multidisciplinary approach (82%), but only 58% could recognize differential diagnoses and had a correct idea regarding the prognosis of CVI. There was no correlation between the number of patients diagnosed per month by the respondent with knowledge of the disease. Conclusion: In this pilot study, ophthalmologists were found to have limited knowledge regarding clinical features, investigation, differential diagnosis, and visual prognosis of CVI in children. There is a need to improve awareness regarding CVI among ophthalmologists. PMID:29380776

  19. Corrective responses in human food intake identified from an analysis of 7-d food-intake records2

    PubMed Central

    Bray, George A; Flatt, Jean-Pierre; Volaufova, Julia; DeLany, James P; Champagne, Catherine M

    2009-01-01

    Background We tested the hypothesis that ad libitum food intake shows corrective responses over periods of 1–5 d. Design This was a prospective study of food intake in women. Methods Two methods, a weighed food intake and a measured food intake, were used to determine daily nutrient intake during 2 wk in 20 women. Energy expenditure with the use of doubly labeled water was done contemporaneously with the weighed food-intake record. The daily deviations in macronutrient and energy intake from the average 7-d values were compared with the deviations observed 1, 2, 3, 4, and 5 d later to estimate the corrective responses. Results Both methods of recording food intake gave similar patterns of macronutrient and total energy intakes and for deviations from average intakes. The intraindividual CVs for energy intake ranged from ±12% to ±47% with an average of ±25%. Reported energy intake was 85.5–95.0% of total energy expenditure determined by doubly labeled water. Significant corrective responses were observed in food intakes with a 3- to 4-d lag that disappeared when data were randomized within each subject. Conclusions Human beings show corrective responses to deviations from average energy and macronutrient intakes with a lag time of 3–4 d, but not 1–2 d. This suggests that short-term studies may fail to recognize important signals of food-intake regulation that operate over several days. These corrective responses probably play a crucial role in bringing about weight stability. PMID:19064509

  20. Correction of contracture and recurrence rates of Dupuytren contracture following invasive treatment: the importance of clear definitions.

    PubMed

    Werker, Paul M N; Pess, Gary M; van Rijssen, Annet L; Denkler, Keith

    2012-10-01

    To call attention to the wide variety of definitions for recurrence that have been employed in studies of different invasive procedures for the treatment of Dupuytren contracture and how this important limitation has contributed to the wide range of reported results. This study reviewed definitions and rates of contracture correction and recurrence in patients undergoing invasive treatment of Dupuytren contracture. A literature search was carried out in January 2011 using the terms "Dupuytren" AND ("fasciectomy" OR "fasciotomy" OR "dermofasciectomy" OR "aponeurotomy" OR "aponeurectomy") and limited to studies in English. The search returned 218 studies, of which 21 had definitions, quantitative results for contracture correction and recurrence, and a sample size of at least 20 patients. Definitions for correction of contracture and recurrence varied greatly among articles and were almost always qualitative. Percentages of patients who achieved correction of contracture (ie, responder rate) when evaluated at various times after completion of surgery ranged from 15% to 96% for fasciectomy/aponeurectomy. Responder rates were not reported for fasciotomy/aponeurotomy. Recurrence rates ranged from 12% to 73% for patients treated with fasciectomy/aponeurectomy and from 33% to 100% for fasciotomy/aponeurotomy. Review of these reports underscored the difficulty involved in comparing correction of contracture and recurrence rates for different surgical interventions because of differences in definition and duration of follow-up. Clearly defined objective definitions for correction of contracture and for recurrence are needed for more meaningful comparisons of results achieved with different surgical interventions. Recurrence after surgical intervention for Dupuytren contracture is common. This study, which evaluated reported rates of recurrence following surgical treatment of Dupuytren contracture, provides clinicians with practical information regarding expected long-term outcomes of surgical treatment choices. Economic and decision analysis III. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. The Relationship among Correct and Error Oral Reading Rates and Comprehension.

    ERIC Educational Resources Information Center

    Roberts, Michael; Smith, Deborah Deutsch

    1980-01-01

    Eight learning disabled boys (10 to 12 years old) who were seriously deficient in both their oral reading and comprehension performances participated in the study which investigated, through an applied behavior analysis model, the interrelationships of three reading variables--correct oral reading rates, error oral reading rates, and percentage of…

  2. Analysis of ionospheric refraction error corrections for GRARR systems

    NASA Technical Reports Server (NTRS)

    Mallinckrodt, A. J.; Parker, H. C.; Berbert, J. H.

    1971-01-01

    A determination is presented of the ionospheric refraction correction requirements for the Goddard range and range rate (GRARR) S-band, modified S-band, very high frequency (VHF), and modified VHF systems. The relation ships within these four systems are analyzed to show that the refraction corrections are the same for all four systems and to clarify the group and phase nature of these corrections. The analysis is simplified by recognizing that the range rate is equivalent to a carrier phase range change measurement. The equation for the range errors are given.

  3. Do doctors understand the test characteristics of lung cancer screening?

    PubMed

    Schmidt, Richard; Breyer, Marie; Breyer-Kohansal, Robab; Urban, Matthias; Funk, Georg-Christian

    2018-04-01

    Screening for lung cancer with a low-dose computed tomography (CT) scan is estimated to prevent 3 deaths per 1000 individuals at high risk; however, false positive results and radiation exposure are relevant harms and deserve careful consideration. Screening candidates can only make an autonomous decision if doctors correctly inform them of the pros and cons of the method; therefore, this study aimed to evaluate whether doctors understand the test characteristics of lung cancer screening. In a randomized trial 556 doctors (members of the Austrian Respiratory Society) were invited to answer questions regarding lung cancer screening based on online case vignettes. Half of the participants were randomized to the group 'solutions provided' and received the correct solutions in advance. The group 'solutions withheld' had to rely on prior knowledge or estimates. The primary endpoint was the between-group difference in the estimated number of deaths preventable by screening. Secondary endpoints were the between-group differences in the prevalence of lung cancer, prevalence of a positive screening results, sensitivity, specificity, positive predictive value, and false negative rate. Estimations were also compared with current data from the literature. The response rate was 29% in both groups. The reduction in the number of deaths due to screening was overestimated six-fold (95% confidence interval CI: 4-8) compared with the actual data, and there was no effect of group allocation. Providing the correct solutions to doctors had no systematic effect on their answers. Doctors poorly understand the test characteristics of lung cancer screening. Providing the correct solutions in advance did not improve the answers. Continuing education regarding lung cancer screening and the interpretation of test characteristics may be a simple remedy. Clinical trial registered with www.clinicaltrials.gov (NCT02542332).

  4. Passive ultra-brief video training improves performance of compression-only cardiopulmonary resuscitation.

    PubMed

    Benoit, Justin L; Vogele, Jennifer; Hart, Kimberly W; Lindsell, Christopher J; McMullan, Jason T

    2017-06-01

    Bystander compression-only cardiopulmonary resuscitation (CPR) improves survival after out-of-hospital cardiac arrest. To broaden CPR training, 1-2min ultra-brief videos have been disseminated via the Internet and television. Our objective was to determine whether participants passively exposed to a televised ultra-brief video perform CPR better than unexposed controls. This before-and-after study was conducted with non-patients in an urban Emergency Department waiting room. The intervention was an ultra-brief CPR training video displayed via closed-circuit television 3-6 times/hour. Participants were unaware of the study and not told to watch the video. Pre-intervention, no video was displayed. Participants were asked to demonstrate compression-only CPR on a manikin. Performance was scored based on critical actions: check for responsiveness, call for help, begin compressions immediately, and correct hand placement, compression rate and depth. The primary outcome was the proportion of participants who performed all actions correctly. There were 50 control and 50 exposed participants. Mean age was 37, 51% were African-American, 52% were female, and 10% self-reported current CPR certification. There were no statistically significant differences in baseline characteristics between groups. The number of participants who performed all actions correctly was 0 (0%) control vs. 10 (20%) exposed (difference 20%, 95% confidence interval [CI] 8.9-31.1%, p<0.001). Correct compression rate and depth were 11 (22%) control vs. 22 (44%) exposed (22%, 95% CI 4.1-39.9%, p=0.019), and 5 (10%) control vs. 15 (30%) exposed (20%, 95% CI 4.8-35.2%, p=0.012), respectively. Passive ultra-brief video training is associated with improved performance of compression-only CPR. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. MO-DE-BRA-02: SIMAC: A Simulation Tool for Teaching Linear Accelerator Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlone, M; Harnett, N; Department of Radiation Oncology, University of Toronto, Toronto, Ontario

    Purpose: The first goal of this work is to develop software that can simulate the physics of linear accelerators (linac). The second goal is to show that this simulation tool is effective in teaching linac physics to medical physicists and linac service engineers. Methods: Linacs were modeled using analytical expressions that can correctly describe the physical response of a linac to parameter changes in real time. These expressions were programmed with a graphical user interface in order to produce an environment similar to that of linac service mode. The software, “SIMAC”, has been used as a learning aid in amore » professional development course 3 times (2014 – 2016) as well as in a physics graduate program. Exercises were developed to supplement the didactic components of the courses consisting of activites designed to reinforce the concepts of beam loading; the effect of steering coil currents on beam symmetry; and the relationship between beam energy and flatness. Results: SIMAC was used to teach 35 professionals (medical physicists; regulators; service engineers; 1 week course) as well as 20 graduate students (1 month project). In the student evaluations, 85% of the students rated the effectiveness of SIMAC as very good or outstanding, and 70% rated the software as the most effective part of the courses. Exercise results were collected showing that 100% of the students were able to use the software correctly. In exercises involving gross changes to linac operating points (i.e. energy changes) the majority of students were able to correctly perform these beam adjustments. Conclusion: Software simulation(SIMAC), can be used to effectively teach linac physics. In short courses, students were able to correctly make gross parameter adjustments that typically require much longer training times using conventional training methods.« less

  6. Quality assurance in proton beam therapy using a plastic scintillator and a commercially available digital camera.

    PubMed

    Almurayshid, Mansour; Helo, Yusuf; Kacperek, Andrzej; Griffiths, Jennifer; Hebden, Jem; Gibson, Adam

    2017-09-01

    In this article, we evaluate a plastic scintillation detector system for quality assurance in proton therapy using a BC-408 plastic scintillator, a commercial camera, and a computer. The basic characteristics of the system were assessed in a series of proton irradiations. The reproducibility and response to changes of dose, dose-rate, and proton energy were determined. Photographs of the scintillation light distributions were acquired, and compared with Geant4 Monte Carlo simulations and with depth-dose curves measured with an ionization chamber. A quenching effect was observed at the Bragg peak of the 60 MeV proton beam where less light was produced than expected. We developed an approach using Birks equation to correct for this quenching. We simulated the linear energy transfer (LET) as a function of depth in Geant4 and found Birks constant by comparing the calculated LET and measured scintillation light distribution. We then used the derived value of Birks constant to correct the measured scintillation light distribution for quenching using Geant4. The corrected light output from the scintillator increased linearly with dose. The system is stable and offers short-term reproducibility to within 0.80%. No dose rate dependency was observed in this work. This approach offers an effective way to correct for quenching, and could provide a method for rapid, convenient, routine quality assurance for clinical proton beams. Furthermore, the system has the advantage of providing 2D visualization of individual radiation fields, with potential application for quality assurance of complex, time-varying fields. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  7. 30 CFR 1227.501 - What are a State's responsibilities to ensure that reporters correct erroneous data?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .../agreement numbers, and missing data fields; (c) Submit accepted and corrected lines to ONRR to allow... that reporters correct erroneous data? 1227.501 Section 1227.501 Mineral Resources OFFICE OF NATURAL... reporters correct erroneous data? To ensure the correction of erroneous data, you must: (a) Ensure...

  8. 30 CFR 1227.501 - What are a State's responsibilities to ensure that reporters correct erroneous data?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .../agreement numbers, and missing data fields; (c) Submit accepted and corrected lines to ONRR to allow... that reporters correct erroneous data? 1227.501 Section 1227.501 Mineral Resources OFFICE OF NATURAL... reporters correct erroneous data? To ensure the correction of erroneous data, you must: (a) Ensure...

  9. 30 CFR 1227.501 - What are a State's responsibilities to ensure that reporters correct erroneous data?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .../agreement numbers, and missing data fields; (c) Submit accepted and corrected lines to ONRR to allow... that reporters correct erroneous data? 1227.501 Section 1227.501 Mineral Resources OFFICE OF NATURAL... reporters correct erroneous data? To ensure the correction of erroneous data, you must: (a) Ensure...

  10. 30 CFR 227.501 - What are a State's responsibilities to ensure that reporters correct erroneous data?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .../agreement numbers, and missing data fields; (c) Submit accepted and corrected lines to MMS to allow... that reporters correct erroneous data? 227.501 Section 227.501 Mineral Resources MINERALS MANAGEMENT... reporters correct erroneous data? To ensure the correction of erroneous data, you must: (a) Ensure...

  11. Novel method to construct large-scale design space in lubrication process utilizing Bayesian estimation based on a small-scale design-of-experiment and small sets of large-scale manufacturing data.

    PubMed

    Maeda, Jin; Suzuki, Tatsuya; Takayama, Kozo

    2012-12-01

    A large-scale design space was constructed using a Bayesian estimation method with a small-scale design of experiments (DoE) and small sets of large-scale manufacturing data without enforcing a large-scale DoE. The small-scale DoE was conducted using various Froude numbers (X(1)) and blending times (X(2)) in the lubricant blending process for theophylline tablets. The response surfaces, design space, and their reliability of the compression rate of the powder mixture (Y(1)), tablet hardness (Y(2)), and dissolution rate (Y(3)) on a small scale were calculated using multivariate spline interpolation, a bootstrap resampling technique, and self-organizing map clustering. The constant Froude number was applied as a scale-up rule. Three experiments under an optimal condition and two experiments under other conditions were performed on a large scale. The response surfaces on the small scale were corrected to those on a large scale by Bayesian estimation using the large-scale results. Large-scale experiments under three additional sets of conditions showed that the corrected design space was more reliable than that on the small scale, even if there was some discrepancy in the pharmaceutical quality between the manufacturing scales. This approach is useful for setting up a design space in pharmaceutical development when a DoE cannot be performed at a commercial large manufacturing scale.

  12. Design space construction of multiple dose-strength tablets utilizing bayesian estimation based on one set of design-of-experiments.

    PubMed

    Maeda, Jin; Suzuki, Tatsuya; Takayama, Kozo

    2012-01-01

    Design spaces for multiple dose strengths of tablets were constructed using a Bayesian estimation method with one set of design of experiments (DoE) of only the highest dose-strength tablet. The lubricant blending process for theophylline tablets with dose strengths of 100, 50, and 25 mg is used as a model manufacturing process in order to construct design spaces. The DoE was conducted using various Froude numbers (X(1)) and blending times (X(2)) for theophylline 100-mg tablet. The response surfaces, design space, and their reliability of the compression rate of the powder mixture (Y(1)), tablet hardness (Y(2)), and dissolution rate (Y(3)) of the 100-mg tablet were calculated using multivariate spline interpolation, a bootstrap resampling technique, and self-organizing map clustering. Three experiments under an optimal condition and two experiments under other conditions were performed using 50- and 25-mg tablets, respectively. The response surfaces of the highest-strength tablet were corrected to those of the lower-strength tablets by Bayesian estimation using the manufacturing data of the lower-strength tablets. Experiments under three additional sets of conditions of lower-strength tablets showed that the corrected design space made it possible to predict the quality of lower-strength tablets more precisely than the design space of the highest-strength tablet. This approach is useful for constructing design spaces of tablets with multiple strengths.

  13. An intelligent classifier for prognosis of cardiac resynchronization therapy based on speckle-tracking echocardiograms.

    PubMed

    Chao, Pei-Kuang; Wang, Chun-Li; Chan, Hsiao-Lung

    2012-03-01

    Predicting response after cardiac resynchronization therapy (CRT) has been a challenge of cardiologists. About 30% of selected patients based on the standard selection criteria for CRT do not show response after receiving the treatment. This study is aimed to build an intelligent classifier to assist in identifying potential CRT responders by speckle-tracking radial strain based on echocardiograms. The echocardiograms analyzed were acquired before CRT from 26 patients who have received CRT. Sequential forward selection was performed on the parameters obtained by peak-strain timing and phase space reconstruction on speckle-tracking radial strain to find an optimal set of features for creating intelligent classifiers. Support vector machine (SVM) with a linear, quadratic, and polynominal kernel were tested to build classifiers to identify potential responders and non-responders for CRT by selected features. Based on random sub-sampling validation, the best classification performance is correct rate about 95% with 96-97% sensitivity and 93-94% specificity achieved by applying SVM with a quadratic kernel on a set of 3 parameters. The selected 3 parameters contain both indexes extracted by peak-strain timing and phase space reconstruction. An intelligent classifier with an averaged correct rate, sensitivity and specificity above 90% for assisting in identifying CRT responders is built by speckle-tracking radial strain. The classifier can be applied to provide objective suggestion for patient selection of CRT. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. 78 FR 65453 - Hazardous Materials: Corrections and Response to Administrative Appeals (HM-215K, HM-215L, HM...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-31

    ...This final rule corrects editorial errors and amends certain requirements in response to administrative appeals submitted by persons affected by certain final rules published in the Federal Register.

  15. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoerner, Matthew R., E-mail: mrh5038@ufl.edu; Stepusin, Elliott J.; Hyer, Daniel E.

    Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator,more » which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.« less

  16. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.

    PubMed

    Hoerner, Matthew R; Stepusin, Elliott J; Hyer, Daniel E; Hintenlang, David E

    2015-03-01

    Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm(3) Radcal(®) thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm(3) calibrated ionization chamber to measure the reference air kerma. Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

  17. Musical auditory stimulus acutely influences heart rate dynamic responses to medication in subjects with well-controlled hypertension.

    PubMed

    Martiniano, Eli Carlos; Santana, Milana Drumond Ramos; Barros, Érico Luiz Damasceno; do Socorro da Silva, Maria; Garner, David Matthew; de Abreu, Luiz Carlos; Valenti, Vitor E

    2018-01-17

    Music can improve the efficiency of medical treatment when correctly associated with drug action, reducing risk factors involving deteriorating cardiac function. We evaluated the effect of musical auditory stimulus associated with anti-hypertensive medication on heart rate (HR) autonomic control in hypertensive subjects. We evaluated 37 well-controlled hypertensive patients designated for anti-hypertensive medication. Heart rate variability (HRV) was calculated from the HR monitor recordings of two different, randomly sorted protocols (control and music) on two separate days. Patients were examined in a resting condition 10 minutes before medication and 20 minutes, 40 minutes and 60 minutes after oral medication. Music was played throughout the 60 minutes after medication with the same intensity for all subjects in the music protocol. We noted analogous response of systolic and diastolic arterial pressure in both protocols. HR decreased 60 minutes after medication in the music protocol while it remained unchanged in the control protocol. The effects of anti-hypertensive medication on SDNN (Standard deviation of all normal RR intervals), LF (low frequency, nu), HF (high frequency, nu) and alpha-1 scale were more intense in the music protocol. In conclusion, musical auditory stimulus increased HR autonomic responses to anti-hypertensive medication in well-controlled hypertensive subjects.

  18. Thinking about False Belief: It's Not Just What Children Say, but How Long It Takes Them to Say It

    ERIC Educational Resources Information Center

    Atance, Cristina M.; Bernstein, Daniel M.; Meltzoff, Andrew N.

    2010-01-01

    We examined 240 children's (3.5-, 4.5-, and 5.5-year-olds) latency to respond to questions on a battery of false-belief tasks. Response latencies exhibited a significant cross-over interaction as a function of age and response type (correct vs. incorrect). 3.5-year-olds' "in"correct latencies were faster than their correct latencies, whereas the…

  19. Can Fast and Slow Intelligence Be Differentiated?

    ERIC Educational Resources Information Center

    Partchev, Ivailo; De Boeck, Paul

    2012-01-01

    Responses to items from an intelligence test may be fast or slow. The research issue dealt with in this paper is whether the intelligence involved in fast correct responses differs in nature from the intelligence involved in slow correct responses. There are two questions related to this issue: 1. Are the processes involved different? 2. Are the…

  20. Some Direct and Generalized Effects of Replacing an Autistic Man's Echolalia with Correct Responses to Questions.

    ERIC Educational Resources Information Center

    McMorrow, Martin J.; Foxx, R. M.

    1986-01-01

    The use of operant procedures was extended to decrease immediate echolalia and increase appropriate responding to questions of a 21-year-old autistic man. Multiple baseline designs demonstrated that echolalia was rapidly replaced with correct stimulus-specific responses. A variety of generalized improvements were observed in verbal responses to…

  1. Modelling geomorphic responses to human perturbations: Application to the Kander river, Switzerland

    NASA Astrophysics Data System (ADS)

    Ramirez, Jorge; Zischg, Andreas; Schürmann, Stefan; Zimmermann, Markus; Weingartner, Rolf; Coulthard, Tom; Keiler, Margreth

    2017-04-01

    Before 1714 the Kander river (Switzerland) flowed into the Aare river causing massive flooding and for this reason the Kander river was deviated (Kander correction) to lake Thun. The Kander correction was a pioneering hydrological project and induced a major human change to the landscape, but had unintended hydrological and geomorphic impacts that cascaded upstream and downstream. For example doubling the catchment area of Lake Thun, which gave rise to major flood problems, cessation of direct sediment delivery to the Aare, and sediment flux to lake Thun forming the Kander delta. More importantly the Kander correction shortened the Kander river and substantially increased the slope and bed shear of the Kander upstream from the correction. Consequently impacts of the correction cascaded upstream as a migrating knickpoint and eroded the river channel at unprecedented rates. Today we may have at our disposal the theoretical and empirical foundations to foresee the consequences of human intervention into natural systems. One method to investigate such geomorphic changes are numerical models that estimate the evolution of rivers by simulating the movement of water and sediment. Although much progress has been made in the development of these geomorphic models, few models have been tested in circumstances with rare perturbations and extreme forcings. As such, it remains uncertain if geomorphic models are useful and stable in extreme situations that include large movements of sediment and water. Here, in this study, we use historic maps and documents to develop a detailed geomorphic model of the Kander river starting in the year 1714. We use this model to simulate the extreme geomorphic events that preceded the deviation of the Kander river into Lake Thun and simulate changes to the river until conditions become relatively stable. We test our model by replicating long term impacts to the river that include 1) rates of incision within the correction, 2) knickpoint migration, and 3) delta formation in Lake Thun. In doing this we build confidence in the model and gain understanding of how the river system responded to anthropogenic perturbations.

  2. Australian midwives knowledge, attitude and perceived learning needs around perinatal mental health.

    PubMed

    Hauck, Yvonne L; Kelly, Georgina; Dragovic, Milan; Butt, Janice; Whittaker, Pamela; Badcock, Johanna C

    2015-01-01

    a cross sectional survey was undertaken to explore midwives' knowledge of, and attitudes towards, mental health disorders in childbearing women vis-à-vis their perceived mental health learning needs. a 50.1% response rate included 238 midwives employed in the only public tertiary maternity hospital in Western Australia from March to June 2013. The survey comprised a mixture of custom-designed questions and vignettes presenting various disorders. Only 37.6% of midwives felt well-equipped to support women, whilst 50.2% reported insufficient access to information. Demand was highest for education on: personality disorders (77.8%); the impact of childbearing on mental health disorders (74.2%); and skills for handling stress and aggression (57.8%). Knowledge scores were variable: on average eight out of a maximum 13 questions were answered correctly, but few (2.7%) answered more than 11 correctly, and 3.7% scored ≤4 correct. Across disorders, recognition from vignettes was highest for depression (93.9%), and lowest for schizophrenia (65.6%). Surprisingly, there were no associations between general knowledge scores and previous mental health experience, recent professional development, or access to information around mental health. The majority endorsed positive beliefs about midwives' role in mental health assessment, and belief in women's recovery (83.5%), however, cluster analysis of warmth and competence ratings revealed negative stereotyping of mental health disorders. Midwives accept it is their role to assess the mental health status of women but many feel ill-equipped to do so and express a strong desire for further knowledge and skills across a range of perinatal mental health topics. Attitudes to recovery are positive but negative stereotypes exist; therefore awareness of potential bias is important to negate their influence on care. Learning needs may change due to trends in clinical practice. Strategies are needed to recognise negative beliefs and to ensure education is responsive to local contexts. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. [Investigation on malaria knowledge and demands on related training for CDC staff in Qinghai Province, China].

    PubMed

    Shao-Sen, Zhang; Hui-Xia, Cai; Hong, Tu; He, Yan; Na, Liu; Jun-Ying, Ma

    2017-04-07

    To investigate the malaria knowledge of CDC staff and their demands on related training in malaria non-endemic areas, so as to provide the reference for planning the appropriate curriculum. All the participants who were the staff of county CDCs all over Qinghai Province and attended the provincial training workshop were surveyed. A self-administered questionnaire survey was carried out and the data was statistically analyzed. A total of 115 participants were involved in this survey. They were mostly (85.21%) from county CDCs. The general knowledge of malaria among the respondents was well, and the average rate of correct answers was 70.35%. However, the answers to the general knowledge of malaria and anti-malaria treatment were not well enough. The rates of correct answers were 61.96% and 48.99% respectively. The differences among the groups of job title ranking, department of working and level of CDC were not significant ( F = 0.13-2.02, all P > 0.05). The number of correct answers was significantly increased after the training course. The average score after the training was 79.20±15.16 while the pre-training score was 70.34±17.46 ( t = 3.86, P < 0.05), especially in the answers to general malaria knowledge and malaria surveillance and response ( t = 4.30, 4.97, both P < 0.05). The general knowledge of malaria was considered as the most need of training as 80% of the respondents voted "Yes", according to the demand analysis. There was no significant difference among the different groups ( F = 0.61-3.11, both P > 0.05). The malaria knowledge is well mastered by the staff of CDCs in Qinghai Province, and the further training courses are requested and addressed in the target areas such as general malaria knowledge, anti-malaria treatment, malaria surveillance and response.

  4. Net Improvement of Correct Answers to Therapy Questions After PubMed Searches: Pre/Post Comparison

    PubMed Central

    Keepanasseril, Arun

    2013-01-01

    Background Clinicians search PubMed for answers to clinical questions although it is time consuming and not always successful. Objective To determine if PubMed used with its Clinical Queries feature to filter results based on study quality would improve search success (more correct answers to clinical questions related to therapy). Methods We invited 528 primary care physicians to participate, 143 (27.1%) consented, and 111 (21.0% of the total and 77.6% of those who consented) completed the study. Participants answered 14 yes/no therapy questions and were given 4 of these (2 originally answered correctly and 2 originally answered incorrectly) to search using either the PubMed main screen or PubMed Clinical Queries narrow therapy filter via a purpose-built system with identical search screens. Participants also picked 3 of the first 20 retrieved citations that best addressed each question. They were then asked to re-answer the original 14 questions. Results We found no statistically significant differences in the rates of correct or incorrect answers using the PubMed main screen or PubMed Clinical Queries. The rate of correct answers increased from 50.0% to 61.4% (95% CI 55.0%-67.8%) for the PubMed main screen searches and from 50.0% to 59.1% (95% CI 52.6%-65.6%) for Clinical Queries searches. These net absolute increases of 11.4% and 9.1%, respectively, included previously correct answers changing to incorrect at a rate of 9.5% (95% CI 5.6%-13.4%) for PubMed main screen searches and 9.1% (95% CI 5.3%-12.9%) for Clinical Queries searches, combined with increases in the rate of being correct of 20.5% (95% CI 15.2%-25.8%) for PubMed main screen searches and 17.7% (95% CI 12.7%-22.7%) for Clinical Queries searches. Conclusions PubMed can assist clinicians answering clinical questions with an approximately 10% absolute rate of improvement in correct answers. This small increase includes more correct answers partially offset by a decrease in previously correct answers. PMID:24217329

  5. Net improvement of correct answers to therapy questions after pubmed searches: pre/post comparison.

    PubMed

    McKibbon, Kathleen Ann; Lokker, Cynthia; Keepanasseril, Arun; Wilczynski, Nancy L; Haynes, R Brian

    2013-11-08

    Clinicians search PubMed for answers to clinical questions although it is time consuming and not always successful. To determine if PubMed used with its Clinical Queries feature to filter results based on study quality would improve search success (more correct answers to clinical questions related to therapy). We invited 528 primary care physicians to participate, 143 (27.1%) consented, and 111 (21.0% of the total and 77.6% of those who consented) completed the study. Participants answered 14 yes/no therapy questions and were given 4 of these (2 originally answered correctly and 2 originally answered incorrectly) to search using either the PubMed main screen or PubMed Clinical Queries narrow therapy filter via a purpose-built system with identical search screens. Participants also picked 3 of the first 20 retrieved citations that best addressed each question. They were then asked to re-answer the original 14 questions. We found no statistically significant differences in the rates of correct or incorrect answers using the PubMed main screen or PubMed Clinical Queries. The rate of correct answers increased from 50.0% to 61.4% (95% CI 55.0%-67.8%) for the PubMed main screen searches and from 50.0% to 59.1% (95% CI 52.6%-65.6%) for Clinical Queries searches. These net absolute increases of 11.4% and 9.1%, respectively, included previously correct answers changing to incorrect at a rate of 9.5% (95% CI 5.6%-13.4%) for PubMed main screen searches and 9.1% (95% CI 5.3%-12.9%) for Clinical Queries searches, combined with increases in the rate of being correct of 20.5% (95% CI 15.2%-25.8%) for PubMed main screen searches and 17.7% (95% CI 12.7%-22.7%) for Clinical Queries searches. PubMed can assist clinicians answering clinical questions with an approximately 10% absolute rate of improvement in correct answers. This small increase includes more correct answers partially offset by a decrease in previously correct answers.

  6. High speed and adaptable error correction for megabit/s rate quantum key distribution.

    PubMed

    Dixon, A R; Sato, H

    2014-12-02

    Quantum Key Distribution is moving from its theoretical foundation of unconditional security to rapidly approaching real world installations. A significant part of this move is the orders of magnitude increases in the rate at which secure key bits are distributed. However, these advances have mostly been confined to the physical hardware stage of QKD, with software post-processing often being unable to support the high raw bit rates. In a complete implementation this leads to a bottleneck limiting the final secure key rate of the system unnecessarily. Here we report details of equally high rate error correction which is further adaptable to maximise the secure key rate under a range of different operating conditions. The error correction is implemented both in CPU and GPU using a bi-directional LDPC approach and can provide 90-94% of the ideal secure key rate over all fibre distances from 0-80 km.

  7. High speed and adaptable error correction for megabit/s rate quantum key distribution

    PubMed Central

    Dixon, A. R.; Sato, H.

    2014-01-01

    Quantum Key Distribution is moving from its theoretical foundation of unconditional security to rapidly approaching real world installations. A significant part of this move is the orders of magnitude increases in the rate at which secure key bits are distributed. However, these advances have mostly been confined to the physical hardware stage of QKD, with software post-processing often being unable to support the high raw bit rates. In a complete implementation this leads to a bottleneck limiting the final secure key rate of the system unnecessarily. Here we report details of equally high rate error correction which is further adaptable to maximise the secure key rate under a range of different operating conditions. The error correction is implemented both in CPU and GPU using a bi-directional LDPC approach and can provide 90–94% of the ideal secure key rate over all fibre distances from 0–80 km. PMID:25450416

  8. Structural learning in feedforward and feedback control.

    PubMed

    Yousif, Nada; Diedrichsen, Jörn

    2012-11-01

    For smooth and efficient motor control, the brain needs to make fast corrections during the movement to resist possible perturbations. It also needs to adapt subsequent movements to improve future performance. It is important that both feedback corrections and feedforward adaptation need to be made based on noisy and often ambiguous sensory data. Therefore, the initial response of the motor system, both for online corrections and adaptive responses, is guided by prior assumptions about the likely structure of perturbations. In the context of correcting and adapting movements perturbed by a force field, we asked whether these priors are hard wired or whether they can be modified through repeated exposure to differently shaped force fields. We found that both feedback corrections to unexpected perturbations and feedforward adaptation to a new force field changed, such that they were appropriate to counteract the type of force field that participants had experienced previously. We then investigated whether these changes were driven by a common mechanism or by two separate mechanisms. Participants experienced force fields that were either temporally consistent, causing sustained adaptation, or temporally inconsistent, causing little overall adaptation. We found that the consistent force fields modified both feedback and feedforward responses. In contrast, the inconsistent force field modified the temporal shape of feedback corrections but not of the feedforward adaptive response. These results indicate that responses to force perturbations can be modified in a structural manner and that these modifications are at least partly dissociable for feedback and feedforward control.

  9. Structural learning in feedforward and feedback control

    PubMed Central

    Diedrichsen, Jörn

    2012-01-01

    For smooth and efficient motor control, the brain needs to make fast corrections during the movement to resist possible perturbations. It also needs to adapt subsequent movements to improve future performance. It is important that both feedback corrections and feedforward adaptation need to be made based on noisy and often ambiguous sensory data. Therefore, the initial response of the motor system, both for online corrections and adaptive responses, is guided by prior assumptions about the likely structure of perturbations. In the context of correcting and adapting movements perturbed by a force field, we asked whether these priors are hard wired or whether they can be modified through repeated exposure to differently shaped force fields. We found that both feedback corrections to unexpected perturbations and feedforward adaptation to a new force field changed, such that they were appropriate to counteract the type of force field that participants had experienced previously. We then investigated whether these changes were driven by a common mechanism or by two separate mechanisms. Participants experienced force fields that were either temporally consistent, causing sustained adaptation, or temporally inconsistent, causing little overall adaptation. We found that the consistent force fields modified both feedback and feedforward responses. In contrast, the inconsistent force field modified the temporal shape of feedback corrections but not of the feedforward adaptive response. These results indicate that responses to force perturbations can be modified in a structural manner and that these modifications are at least partly dissociable for feedback and feedforward control. PMID:22896725

  10. Design and Implementation of a Novel Web-Based E-Learning Tool for Education of Health Professionals on the Antibiotic Vancomycin.

    PubMed

    Bond, Stuart Evan; Crowther, Shelley P; Adhikari, Suman; Chubaty, Adriana J; Yu, Ping; Borchard, Jay P; Boutlis, Craig Steven; Yeo, Wilfred Winston; Miyakis, Spiros

    2017-03-30

    Traditional approaches to health professional education are being challenged by increased clinical demands and decreased available time. Web-based e-learning tools offer a convenient and effective method of delivering education, particularly across multiple health care facilities. The effectiveness of this model for health professional education needs to be explored in context. The study aimed to (1) determine health professionals' experience and knowledge of clinical use of vancomycin, an antibiotic used for treatment of serious infections caused by methicillin-resistant Staphylococcus aureus (MRSA) and (2) describe the design and implementation of a Web-based e-learning tool created to improve knowledge in this area. We conducted a study on the design and implementation of a video-enhanced, Web-based e-learning tool between April 2014 and January 2016. A Web-based survey was developed to determine prior experience and knowledge of vancomycin use among nurses, doctors, and pharmacists. The Vancomycin Interactive (VI) involved a series of video clips interspersed with question and answer scenarios, where a correct response allowed for progression. Dramatic tension and humor were used as tools to engage users. Health professionals' knowledge of clinical vancomycin use was obtained from website data; qualitative participant feedback was also collected. From the 577 knowledge survey responses, pharmacists (n=70) answered the greatest number of questions correctly (median score 4/5), followed by doctors (n=271; 3/5) and nurses (n=236; 2/5; P<.001). Survey questions on target trough concentration (75.0%, 433/577) and rate of administration (64.9%, 375/577) were answered most correctly, followed by timing of first level (49%, 283/577), maintenance dose (41.9%, 242/577), and loading dose (38.0%, 219/577). Self-reported "very" and "reasonably" experienced health professionals were also more likely to achieve correct responses. The VI was completed by 163 participants during the study period. The rate of correctly answered VI questions on first attempt was 65% for nurses (n=63), 68% for doctors (n=86), and 82% for pharmacists (n=14; P<.001), reflecting a similar pattern to the knowledge survey. Knowledge gaps were identified for loading dose (39.2% correct on first attempt; 64/163), timing of first trough level (50.3%, 82/163), and subsequent trough levels (47.9%, 78/163). Of the 163 participants, we received qualitative user feedback from 51 participants following completion of the VI. Feedback was predominantly positive with themes of "entertaining," "engaging," and "fun" identified; however, there were some technical issues identified relating to accessibility from different operating systems and browsers. A novel Web-based e-learning tool was successfully developed combining game design principles and humor to improve user engagement. Knowledge gaps were identified that allowed for targeting of future education strategies. The VI provides an innovative model for delivering Web-based education to busy health professionals in different locations. ©Stuart Evan Bond, Shelley P Crowther, Suman Adhikari, Adriana J Chubaty, Ping Yu, Jay P Borchard, Craig Steven Boutlis, Wilfred Winston Yeo, Spiros Miyakis. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 30.03.2017.

  11. Priors Engaged in Long-Latency Responses to Mechanical Perturbations Suggest a Rapid Update in State Estimation

    PubMed Central

    Crevecoeur, Frédéric; Scott, Stephen H.

    2013-01-01

    In every motor task, our brain must handle external forces acting on the body. For example, riding a bike on cobblestones or skating on irregular surface requires us to appropriately respond to external perturbations. In these situations, motor predictions cannot help anticipate the motion of the body induced by external factors, and direct use of delayed sensory feedback will tend to generate instability. Here, we show that to solve this problem the motor system uses a rapid sensory prediction to correct the estimated state of the limb. We used a postural task with mechanical perturbations to address whether sensory predictions were engaged in upper-limb corrective movements. Subjects altered their initial motor response in ∼60 ms, depending on the expected perturbation profile, suggesting the use of an internal model, or prior, in this corrective process. Further, we found trial-to-trial changes in corrective responses indicating a rapid update of these perturbation priors. We used a computational model based on Kalman filtering to show that the response modulation was compatible with a rapid correction of the estimated state engaged in the feedback response. Such a process may allow us to handle external disturbances encountered in virtually every physical activity, which is likely an important feature of skilled motor behaviour. PMID:23966846

  12. Generalized quantum kinetic expansion: Higher-order corrections to multichromophoric Förster theory

    NASA Astrophysics Data System (ADS)

    Wu, Jianlan; Gong, Zhihao; Tang, Zhoufei

    2015-08-01

    For a general two-cluster energy transfer network, a new methodology of the generalized quantum kinetic expansion (GQKE) method is developed, which predicts an exact time-convolution equation for the cluster population evolution under the initial condition of the local cluster equilibrium state. The cluster-to-cluster rate kernel is expanded over the inter-cluster couplings. The lowest second-order GQKE rate recovers the multichromophoric Förster theory (MCFT) rate. The higher-order corrections to the MCFT rate are systematically included using the continued fraction resummation form, resulting in the resummed GQKE method. The reliability of the GQKE methodology is verified in two model systems, revealing the relevance of higher-order corrections.

  13. Behavioral sensitivity to changing reinforcement contingencies in attention-deficit hyperactivity disorder.

    PubMed

    Alsop, Brent; Furukawa, Emi; Sowerby, Paula; Jensen, Stephanie; Moffat, Cara; Tripp, Gail

    2016-08-01

    Altered sensitivity to positive reinforcement has been hypothesized to contribute to the symptoms of attention-deficit hyperactivity disorder (ADHD). In this study, we evaluated the ability of children with and without ADHD to adapt their behavior to changing reinforcer availability. Of one hundred sixty-seven children, 97 diagnosed with ADHD completed a signal-detection task in which correct discriminations between two stimuli were associated with different frequencies of reinforcement. The response alternative associated with the higher rate of reinforcement switched twice during the task without warning. For a subset of participants, this was followed by trials for which no reinforcement was delivered, irrespective of performance. Children in both groups developed an initial bias toward the more frequently reinforced response alternative. When the response alternative associated with the higher rate of reinforcement switched, the children's response allocation (bias) followed suit, but this effect was significantly smaller for children with ADHD. When reinforcement was discontinued, only children in the control group modified their response pattern. Children with ADHD adjust their behavioral responses to changing reinforcer availability less than typically developing children, when reinforcement is intermittent and the association between an action and its consequences is uncertain. This may explain the difficulty children with ADHD have adapting their behavior to new situations, with different reinforcement contingencies, in daily life. © 2016 Association for Child and Adolescent Mental Health.

  14. Response theory of the ergodic many-body delocalized phase: Keldysh Finkel'stein sigma models and the 10-fold way

    NASA Astrophysics Data System (ADS)

    Liao, Yunxiang; Levchenko, Alex; Foster, Matthew S.

    2017-11-01

    We derive the finite temperature Keldysh response theory for interacting fermions in the presence of quenched short-ranged disorder, as applicable to any of the 10 Altland-Zirnbauer classes in an Anderson delocalized phase with at least a U(1) continuous symmetry. In this formulation of the interacting Finkel'stein nonlinear sigma model, the statistics of one-body wave functions are encoded by the constrained matrix field, while physical correlations follow from the hydrodynamic density or spin response field, which decouples the interactions. Integrating out the matrix field first, we obtain weak (anti) localization and Altshuler-Aronov quantum conductance corrections from the hydrodynamic response function. This procedure automatically incorporates the correct infrared cutoff physics, and in particular gives the Altshuler-Aronov-Khmelnitsky (AAK) equations for dephasing of weak (anti)localization due to electron-electron collisions. We explicate the method by deriving known quantumcorrections in two dimensions for the symplectic metal class AII, as well as the spin-SU(2) invariant superconductor classes C and CI. We show that quantum conductance corrections due to the special modes at zero energy in nonstandard classes are automatically cut off by temperature, as previously expected, while the Wigner-Dyson class Cooperon modes that persist to all energies are cut by dephasing. We also show that for short-ranged interactions, the standard self-consistent solution for the dephasing rate is equivalent to a particular summation of diagrams via the self-consistent Born approximation. This should be compared to the corresponding AAK solution for long-ranged Coulomb interactions, which exploits the Markovian noise correlations induced by thermal fluctuations of the electromagnetic field. We discuss prospects for exploring the many-body localization transition as a dephasing catastrophe in short-range interacting models, as encountered by approaching from the ergodic side.

  15. LINEAR LATTICE AND TRAJECTORY RECONSTRUCTION AND CORRECTION AT FAST LINEAR ACCELERATOR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romanov, A.; Edstrom, D.; Halavanau, A.

    2017-07-16

    The low energy part of the FAST linear accelerator based on 1.3 GHz superconducting RF cavities was successfully commissioned [1]. During commissioning, beam based model dependent methods were used to correct linear lattice and trajectory. Lattice correction algorithm is based on analysis of beam shape from profile monitors and trajectory responses to dipole correctors. Trajectory responses to field gradient variations in quadrupoles and phase variations in superconducting RF cavities were used to correct bunch offsets in quadrupoles and accelerating cavities relative to their magnetic axes. Details of used methods and experimental results are presented.

  16. Overdistribution illusions: Categorical judgments produce them, confidence ratings reduce them.

    PubMed

    Brainerd, C J; Nakamura, K; Reyna, V F; Holliday, R E

    2017-01-01

    Overdistribution is a form of memory distortion in which an event is remembered as belonging to too many episodic states, states that are logically or empirically incompatible with each other. We investigated a response formatting method of suppressing 2 basic types of overdistribution, disjunction and conjunction illusions, which parallel some classic illusions in the judgment and decision making literature. In this method, subjects respond to memory probes by rating their confidence that test cues belong to specific episodic states (e.g., presented on List 1, presented on List 2), rather than by making the usual categorical judgments about those states. The central prediction, which was derived from the task calibration principle of fuzzy-trace theory, was that confidence ratings should reduce overdistribution by diminishing subjects' reliance on noncompensatory gist memories. The data of 3 experiments agreed with that prediction. In Experiment 1, there were reliable disjunction illusions with categorical judgments but not with confidence ratings. In Experiment 2, both response formats produced reliable disjunction illusions, but those for confidence ratings were much smaller than those for categorical judgments. In Experiment 3, there were reliable conjunction illusions with categorical judgments but not with confidence ratings. Apropos of recent controversies over confidence-accuracy correlations in memory, such correlations were positive for hits, negative for correct rejections, and the 2 types of correlations were of equal magnitude. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  17. Overdistribution Illusions: Categorical Judgments Produce Them, Confidence Ratings Reduce Them

    PubMed Central

    Brainerd, C. J.; Nakamura, K.; Reyna, V. F.; Holliday, R. E.

    2017-01-01

    Overdistribution is a form of memory distortion in which an event is remembered as belonging to too many episodic states, states that are logically or empirically incompatible with each other. We investigated a response formatting method of suppressing two basic types of overdistribution, disjunction and conjunction illusions, which parallel some classic illusions in the judgment and decision making literature. In this method, subjects respond to memory probes by rating their confidence that test cues belong to specific episodic states (e.g., presented on List 1, presented on List 2), rather than by making the usual categorical judgments about those states. The central prediction, which was derived from the task calibration principle of fuzzy-trace theory, was that confidence ratings should reduce overdistribution by diminishing subjects’ reliance on noncompensatory gist memories. The data of three experiments agreed with that prediction. In Experiment 1, there were reliable disjunction illusions with categorical judgments but not with confidence ratings. In Experiment 2, both response formats produced reliable disjunction illusions, but those for confidence ratings were much smaller than those for categorical judgments. In Experiment 3, there were reliable conjunction illusions with categorical judgments but not with confidence ratings. Apropos of recent controversies over confidence-accuracy correlations in memory, such correlations were positive for hits, negative for correct rejections, and the two types of correlations were of equal magnitude. PMID:28054811

  18. Inhibition of Microprocessor Function during the Activation of the Type I Interferon Response.

    PubMed

    Witteveldt, Jeroen; Ivens, Alasdair; Macias, Sara

    2018-06-12

    Type I interferons (IFNs) are central components of the antiviral response. Most cell types respond to viral infections by secreting IFNs, but the mechanisms that regulate correct expression of these cytokines are not completely understood. Here, we show that activation of the type I IFN response regulates the expression of miRNAs in a post-transcriptional manner. Activation of IFN expression alters the binding of the Microprocessor complex to pri-miRNAs, reducing its processing rate and thus leading to decreased levels of a subset of mature miRNAs in an IRF3-dependent manner. The rescue of Microprocessor function during the antiviral response downregulates the levels of IFN-β and IFN-stimulated genes. All these findings support a model by which the inhibition of Microprocessor activity is an essential step to induce a robust type I IFN response in mammalian cells. Copyright © 2018 The Author(s). Published by Elsevier Inc. All rights reserved.

  19. Predictors of response to neuroleptic treatment in schizophrenia.

    PubMed

    Stern, R G; Kahn, R S; Davidson, M

    1993-06-01

    Baseline symptom severity, early reduction in symptom severity, initial subjective response to neuroleptic treatment, the degree of brain atrophy, and early changes in pHVA levels appear to predict treatment outcome in schizophrenic patients. Computerized EEG results, neuropsychological and neurophysiologic tests, and baseline pHVA concentrations require further examination. Only a limited proportion of variance in treatment response, however, could be explained by either of the nine predictors alone or combined. Therefore, further research is necessary to discover yet unidentified determinants of treatment response. Future studies should test the validity and reliability of these five promising predictors in large groups of male and female patients, employ high standards for assessment reliability of clinical parameters, and use absolute rating scores on psychopathology as well as functional scales for the definition of good and poor treatment response. Furthermore, the statistical approach for data analysis should take in consideration the need for appropriate corrections when multiple correlations are performed and should test the extent to which these predictors are interdependent.

  20. Science in the Making: Right Hand, Left Hand. III: Estimating historical rates of left-handedness.

    PubMed

    McManus, I C; Moore, James; Freegard, Matthew; Rawles, Richard

    2010-01-01

    The BBC television programme Right Hand, Left Hand, broadcast in August 1953, used a postal questionnaire to ask viewers about their handedness. Respondents were born between 1864 and 1948, and in principle therefore the study provides information on rates of left-handedness in those born in the nineteenth century, a group for which few data are otherwise available. A total of 6,549 responses were received, with an overall rate of left-handedness of 15.2%, which is substantially above that expected for a cohort born in the nineteenth and early twentieth centuries. Left-handers are likely to respond preferentially to surveys about handedness, and the extent of over-response can be estimated in modern control data obtained from a handedness website, from the 1953 BBC data, and from Crichton-Browne's 1907 survey, in which there was also a response bias. Response bias appears to have been growing, being relatively greater in the most modern studies. In the 1953 data there is also evidence that left-handers were more common among later rather than early responders, suggesting that left-handers may have been specifically recruited into the study, perhaps by other left-handers who had responded earlier. In the present study the estimated rate of bias was used to correct the nineteenth-century BBC data, which was then combined with other available data as a mixture of two constrained Weibull functions, to obtain an overall estimate of handedness rates in the nineteenth century. The best estimates are that left-handedness was at its nadir of about 3% for those born between about 1880 and 1900. Extrapolating backwards, the rate of left-handedness in the eighteenth century was probably about 10%, with the decline beginning in about 1780, and reaching around 7% in about 1830, although inevitably there are many uncertainties in those estimates. What does seem indisputable is that rates of left-handedness fell during most of the nineteenth century, only subsequently to rise in the twentieth century.

  1. Impact of a Developmental Care Training Course on the Knowledge and Satisfaction of Health Care Professionals in Neonatal Units: A Multicenter Study.

    PubMed

    Mosqueda-Peña, Rocío; Lora-Pablos, David; Pavón-Muñoz, Abraham; Ureta-Velasco, Noelia; Moral-Pumarega, María Teresa; Pallás-Alonso, Carmen Rosa

    2016-04-01

    The impact of health-related continuing education courses on knowledge acquisition and clinical practice is infrequently evaluated, despite higher numbers of people enrolling in them. The majority of health care professionals working in neonatal intensive care units (NICUs) have received no training in developmental care (DC). The purpose of this study was to determine whether participation in a theoretical-practical course on DC had an effect on the degree of knowledge possessed by professionals in general terms and with respect to neonatal intensive care. The relationship between course satisfaction and knowledge acquisition was also studied. This was an observational multicenter study conducted in 20 neonatal units in Madrid. A pre- and post-course questionnaire evaluated both knowledge and satisfaction levels regarding the course on DC and the Newborn Individualized Developmental Care and Assessment Program (NIDCAP). We carried out a multivariate linear regression analysis to determine whether there was a correlation between knowledge gained and satisfaction level. A total of 566 professionals participated, with a 99% pre-course and a 90% post-course response rate. The mean rate of correct pre-course answers was 65%, while the mean rate of post-course correct answers was 81% (p < 0.001). Results were similar at all levels of neonatal care (Level I: 64% vs 80%; Level II: 64% vs. 83%; and 65% vs. 81%). Scores on a scale of satisfaction from 1 to 5 were high (averages of above 4 for all lectures and workshops). Pre-course knowledge scores, but not satisfaction, significantly influenced post-course knowledge (β 0.499; p < 0.01). Previous DC knowledge among Madrid health care professionals was similar, regardless of the level of neonatal care. Course attendance significantly improved the rate of correct answers. Although course satisfaction was high, there did not seem to be a correlation between knowledge gained and satisfaction. Copyright © 2016. Published by Elsevier B.V.

  2. Glacial-interglacial dynamics of Antarctic firn columns: comparison between simulations and ice core air-?15N measurements

    NASA Astrophysics Data System (ADS)

    Capron, E.; Landais, A.; Buiron, D.; Cauquoin, A.; Chappellaz, J. A.; Debret, M.; Jouzel, J.; Leuenberger, M.; Martinerie, P.; Masson-Delmotte, V.; Mulvaney, R.; Parrenin, F.; Prié, F.

    2013-12-01

    Correct estimation of the firn lock-in depth is essential for correctly linking gas and ice chronologies in ice core studies. Here, two approaches to constrain the firn depth evolution in Antarctica are presented over the last deglaciation: outputs of a firn densification model, and measurements of δ15N of N2 in air trapped in ice core, assuming that δ15N is only affected by gravitational fractionation in the firn column. Since the firn densification process is largely governed by surface temperature and accumulation rate, we have investigated four ice cores drilled in coastal (Berkner Island, BI, and James Ross Island, JRI) and semi-coastal (TALDICE and EPICA Dronning Maud Land, EDML) Antarctic regions. Combined with available ice core air- δ15N measurements from the EPICA Dome C (EDC) site, the studied regions encompass a large range of surface accumulation rates and temperature conditions. Our δ15N profiles reveal a heterogeneous response of the firn structure to glacial-interglacial climatic changes. While firn densification simulations correctly predict TALDICE δ15N variations, they systematically fail to capture the large millennial-scale δ15N variations measured at BI and the δ15N glacial levels measured at JRI and EDML - a mismatch previously reported for central East Antarctic ice cores. New constraints of the EDML gas-ice depth offset during the Laschamp event (41 ka) and the last deglaciation do not favour the hypothesis of a large convective zone within the firn as the explanation of the glacial firn model- δ15N data mismatch for this site. While we could not conduct an in-depth study of the influence of impurities in snow for firnification from the existing datasets, our detailed comparison between the δ15N profiles and firn model simulations under different temperature and accumulation rate scenarios suggests that the role of accumulation rate may have been underestimated in the current description of firnification models.

  3. Glacial-interglacial dynamics of Antarctic firn columns: comparison between simulations and ice core air-δ15N measurements

    NASA Astrophysics Data System (ADS)

    Capron, E.; Landais, A.; Buiron, D.; Cauquoin, A.; Chappellaz, J.; Debret, M.; Jouzel, J.; Leuenberger, M.; Martinerie, P.; Masson-Delmotte, V.; Mulvaney, R.; Parrenin, F.; Prié, F.

    2013-05-01

    Correct estimation of the firn lock-in depth is essential for correctly linking gas and ice chronologies in ice core studies. Here, two approaches to constrain the firn depth evolution in Antarctica are presented over the last deglaciation: outputs of a firn densification model, and measurements of δ15N of N2 in air trapped in ice core, assuming that δ15N is only affected by gravitational fractionation in the firn column. Since the firn densification process is largely governed by surface temperature and accumulation rate, we have investigated four ice cores drilled in coastal (Berkner Island, BI, and James Ross Island, JRI) and semi-coastal (TALDICE and EPICA Dronning Maud Land, EDML) Antarctic regions. Combined with available ice core air-δ15N measurements from the EPICA Dome C (EDC) site, the studied regions encompass a large range of surface accumulation rates and temperature conditions. Our δ15N profiles reveal a heterogeneous response of the firn structure to glacial-interglacial climatic changes. While firn densification simulations correctly predict TALDICE δ15N variations, they systematically fail to capture the large millennial-scale δ15N variations measured at BI and the δ15N glacial levels measured at JRI and EDML - a mismatch previously reported for central East Antarctic ice cores. New constraints of the EDML gas-ice depth offset during the Laschamp event (~41 ka) and the last deglaciation do not favour the hypothesis of a large convective zone within the firn as the explanation of the glacial firn model-δ15N data mismatch for this site. While we could not conduct an in-depth study of the influence of impurities in snow for firnification from the existing datasets, our detailed comparison between the δ15N profiles and firn model simulations under different temperature and accumulation rate scenarios suggests that the role of accumulation rate may have been underestimated in the current description of firnification models.

  4. XBT Fall-rate study in the Southern Ocean

    NASA Astrophysics Data System (ADS)

    Ribeiro, N.; Mata, M. M.; Azevedo, J. L.

    2016-02-01

    Several studies have observed a more prominent warming of the Southern Ocean when compared to other ocean regions of the world in response to global climate change. However, the vast majority of available temperature data for that region is composed by eXpendable BathyTermographers profiles (XBTs). These probes are not equipped with a pressure sensor and thus do not measure depth directly. Depth is inferred by a fall-rate equation offered by the manufacturer that does not seem to adequately represent the extremely cold and high viscosity conditions of the region. Probes fall slower than expected and thus lead to an overestimation in heat content for those areas. In this study, a set of 850 collocated XBT (DB/T7 type) and CTD stations obtained from World Ocean Database (2013) and separated by a maximum distance of 12.5 nm and 10 hours is used. Those pairs are used to identify and quantify the depth errors in the XBT's temperature profiles, proposing a regional equation correction able to represent the peculiarities of the region. Hanawa et al. (1995) and Cheng et al. (2014) correction methods were applied to the dataset, with the latter producing better results. For the pairs in Drake Passage (151), South of Africa (244) and South of Tasmania (455), we found the ideal A coefficients to change by -0.88%, -1.4% and -2.2% from the original values, respectively. When a temperature profile is more homogeneous, there is no significant change if different values of B are used, which was proven to be true since they were .0021 for Drake Passage and .0020 for the other chokings. The ideal fall-rate equation for the Southern Ocean was determined using all pairs, being defined as instead of the proposed by the manufacturer. Overall, the results further support the hypothesis of a regional dependence of the XBT fall-rate on water temperature, and suggest the need of developing a bias correction scheme specific for the polar regions.

  5. The value of radiographs obtained during forced traction under general anaesthesia in predicting flexibility in idiopathic scoliosis with Cobb angles exceeding 60 degree.

    PubMed

    Ibrahim, T; Gabbar, O A; El-Abed, K; Hutchinson, M J; Nelson, I W

    2008-11-01

    Our aim in this prospective radiological study was to determine whether the flexibility rate calculated from radiographs obtained during forced traction under general anaesthesia, was better than that of fulcrum-bending radiographs before corrective surgery in predicting the extent of the available correction in patients with idiopathic scoliosis. We evaluated 33 patients with a Cobb angle > 60 degrees on a standing posteroanterior radiograph, who had been treated by posterior correction. Pre-operative standing fulcrum-bending radiographs and those with forced-traction under general anaesthesia were obtained. Post-operative standing radiographs were taken after surgical correction. The mean forced-traction flexibility rate was 55% (SD 11.3) which was significantly higher than the mean fulcrum-bending flexibility rate of 32% (SD 16.1) (p < 0.001). We found no correlation between either the forced-traction or fulcrum-bending flexibility rates and the correction rate post-operatively (p = 0.24 and p = 0.44, respectively). Radiographs obtained during forced traction under general anaesthesia were better at predicting the flexibility of the curve than fulcrum-bending radiographs in curves with a Cobb angle > 60 degrees in the standing position and may identify those patients for whom supplementary anterior surgery can be avoided.

  6. 10 CFR 1008.10 - Action in response to a request for correction or amendment of records.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Action in response to a request for correction or amendment of records. 1008.10 Section 1008.10 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) RECORDS MAINTAINED ON INDIVIDUALS (PRIVACY ACT) Requests for Access or Amendment § 1008.10 Action in response to a...

  7. 10 CFR 1008.10 - Action in response to a request for correction or amendment of records.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Action in response to a request for correction or amendment of records. 1008.10 Section 1008.10 Energy DEPARTMENT OF ENERGY (GENERAL PROVISIONS) RECORDS MAINTAINED ON INDIVIDUALS (PRIVACY ACT) Requests for Access or Amendment § 1008.10 Action in response to a...

  8. How Well Do Molecular and Pedigree Relatedness Correspond, in Populations with Diverse Mating Systems, and Various Types and Quantities of Molecular and Demographic Data?

    PubMed

    Kopps, Anna M; Kang, Jungkoo; Sherwin, William B; Palsbøll, Per J

    2015-06-30

    Kinship analyses are important pillars of ecological and conservation genetic studies with potentially far-reaching implications. There is a need for power analyses that address a range of possible relationships. Nevertheless, such analyses are rarely applied, and studies that use genetic-data-based-kinship inference often ignore the influence of intrinsic population characteristics. We investigated 11 questions regarding the correct classification rate of dyads to relatedness categories (relatedness category assignments; RCA) using an individual-based model with realistic life history parameters. We investigated the effects of the number of genetic markers; marker type (microsatellite, single nucleotide polymorphism SNP, or both); minor allele frequency; typing error; mating system; and the number of overlapping generations under different demographic conditions. We found that (i) an increasing number of genetic markers increased the correct classification rate of the RCA so that up to >80% first cousins can be correctly assigned; (ii) the minimum number of genetic markers required for assignments with 80 and 95% correct classifications differed between relatedness categories, mating systems, and the number of overlapping generations; (iii) the correct classification rate was improved by adding additional relatedness categories and age and mitochondrial DNA data; and (iv) a combination of microsatellite and single-nucleotide polymorphism data increased the correct classification rate if <800 SNP loci were available. This study shows how intrinsic population characteristics, such as mating system and the number of overlapping generations, life history traits, and genetic marker characteristics, can influence the correct classification rate of an RCA study. Therefore, species-specific power analyses are essential for empirical studies. Copyright © 2015 Kopps et al.

  9. Pacing-induced chronic atrial fibrillation impairs sinus node function in dogs. Electrophysiological remodeling.

    PubMed

    Elvan, A; Wylie, K; Zipes, D P

    1996-12-01

    We assessed the effects of pacing-induced chronic atrial fibrillation (AF) on sinus node function, intra-atrial conduction, and atrial refractoriness. In 15 mongrel dogs (20 to 30 kg), AV nodal block was produced by radiofrequency catheter ablation, and a ventricular-inhibited (VVI) pacemaker (Minix 8330, Medtronic) was implanted and programmed to pace at 80 pulses per minute. In 11 of these dogs, right atrial endocardial pacing leads were connected to a pulse generator (Itrel 7432, Medtronic) and set at a rate of 20 Hz to induce AF. Corrected sinus node recovery time, P-wave duration, 24-hour Holter ECG to assess AF duration, maximal heart rate in response to isoproterenol (10 micrograms/min), intrinsic heart rate after administration of atropine (0.04 mg/kg) and propranolol (0.1 mg/kg), and atrial effective refractory periods (ERPs) were obtained at baseline (EPS-1) and after 2 to 6 weeks (EPS-2) of VVI pacing alone (n = 4) or VVI pacing and rapid atrial pacing (n = 11). At EPS-2, corrected sinus node recovery time and P-wave duration were prolonged, maximal heart rate and intrinsic heart rate were decreased, atrial ERPs were shortened, and the duration of AF was increased significantly compared with EPS-1. These changes partially reversed toward baseline 1 week after conversion to sinus rhythm. Sinus node function and AF inducibility observed in the control dogs that underwent ventricular pacing alone (n = 4) did not change. Pacing-induced chronic AF induces sinus node dysfunction, prolongs intra-atrial conduction time, shortens atrial refractoriness, and perpetuates AF, changes that reverse gradually after termination of AF.

  10. Bleed-through correction for rendering and correlation analysis in multi-colour localization microscopy

    PubMed Central

    Kim, Dahan; Curthoys, Nikki M.; Parent, Matthew T.; Hess, Samuel T.

    2015-01-01

    Multi-colour localization microscopy has enabled sub-diffraction studies of colocalization between multiple biological species and quantification of their correlation at length scales previously inaccessible with conventional fluorescence microscopy. However, bleed-through, or misidentification of probe species, creates false colocalization and artificially increases certain types of correlation between two imaged species, affecting the reliability of information provided by colocalization and quantified correlation. Despite the potential risk of these artefacts of bleed-through, neither the effect of bleed-through on correlation nor methods of its correction in correlation analyses has been systematically studied at typical rates of bleed-through reported to affect multi-colour imaging. Here, we present a reliable method of bleed-through correction applicable to image rendering and correlation analysis of multi-colour localization microscopy. Application of our bleed-through correction shows our method accurately corrects the artificial increase in both types of correlations studied (Pearson coefficient and pair correlation), at all rates of bleed-through tested, in all types of correlations examined. In particular, anti-correlation could not be quantified without our bleed-through correction, even at rates of bleed-through as low as 2%. Demonstrated with dichroic-based multi-colour FPALM here, our presented method of bleed-through correction can be applied to all types of localization microscopy (PALM, STORM, dSTORM, GSDIM, etc.), including both simultaneous and sequential multi-colour modalities, provided the rate of bleed-through can be reliably determined. PMID:26185614

  11. Bleed-through correction for rendering and correlation analysis in multi-colour localization microscopy.

    PubMed

    Kim, Dahan; Curthoys, Nikki M; Parent, Matthew T; Hess, Samuel T

    2013-09-01

    Multi-colour localization microscopy has enabled sub-diffraction studies of colocalization between multiple biological species and quantification of their correlation at length scales previously inaccessible with conventional fluorescence microscopy. However, bleed-through, or misidentification of probe species, creates false colocalization and artificially increases certain types of correlation between two imaged species, affecting the reliability of information provided by colocalization and quantified correlation. Despite the potential risk of these artefacts of bleed-through, neither the effect of bleed-through on correlation nor methods of its correction in correlation analyses has been systematically studied at typical rates of bleed-through reported to affect multi-colour imaging. Here, we present a reliable method of bleed-through correction applicable to image rendering and correlation analysis of multi-colour localization microscopy. Application of our bleed-through correction shows our method accurately corrects the artificial increase in both types of correlations studied (Pearson coefficient and pair correlation), at all rates of bleed-through tested, in all types of correlations examined. In particular, anti-correlation could not be quantified without our bleed-through correction, even at rates of bleed-through as low as 2%. Demonstrated with dichroic-based multi-colour FPALM here, our presented method of bleed-through correction can be applied to all types of localization microscopy (PALM, STORM, dSTORM, GSDIM, etc.), including both simultaneous and sequential multi-colour modalities, provided the rate of bleed-through can be reliably determined.

  12. The effect of increased classroom ventilation rate indicated by reduced CO2 concentration on the performance of schoolwork by children.

    PubMed

    Petersen, S; Jensen, K L; Pedersen, A L S; Rasmussen, H S

    2016-06-01

    The article reports on an experiment which investigated the effect of increased classroom ventilation rate on the performance of children aged 10-12 years. The experiment was executed at two different schools (two classrooms at each school) as a double-blind 2 × 2 crossover intervention where four different performance tests were used as surrogates for short-term concentration and logical thinking. Only complete pairs of test responses were included in the within-subject comparisons of performance, and data were not corrected for learning and fatigue effects. Analysis of the total sample suggested the number of correct answers was improved significantly in four of four performance test, addition (6.3%), number comparison (4.8%), grammatical reasoning (3.2%), and reading and comprehension (7.4%), when the outdoor air supply rate was increased from an average of 1.7 (1.4-2.0) to 6.6 l/s per person. The increased outdoor air supply rate did not have any significant effect on the number of errors in any of the performance tests. Results from questionnaires regarding pupil perception of the indoor environment, reported Sick Building Syndrome symptoms, and motivation suggested that the study classroom air was perceived more still and pupil were experiencing less pain in the eyes in the recirculation condition compared to the fresh air condition. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Influence of dopaminergic medication on automatic postural responses and balance impairment in Parkinson's disease.

    PubMed

    Bloem, B R; Beckley, D J; van Dijk, J G; Zwinderman, A H; Remler, M P; Roos, R A

    1996-09-01

    It is still unclear why balance impairment in Parkinson's disease (PD) often responds insufficiently to dopaminergic medication. We have studied this issue in 23 patients with idiopathic PD and 24 healthy controls. Our specific purposes were (a) to investigate the contribution of abnormal automatic postural responses to balance impairment in PD and (b) to assess the influence of dopaminergic medication on abnormal automatic postural responses and balance impairment. Standing subjects received 4 degrees "toe-up" rotational perturbations of a supporting forceplate. We bilaterally recorded posturally destabilizing medium latency (ML) responses from the stretched gastrocnemius muscles and functionally corrective long latency (LL) responses from the shortened tibialis anterior (TA) muscles. We also assessed changes in the center of foot pressure (CFP) and the center of gravity (COG). All patients were tested in the "off" and "on" phases. All controls were tested and retested after 1 h. During the off phase, we found enlarged ML amplitudes and diminished LL amplitudes in patients, together with a markedly increased posterior displacement of the COG. The abnormal ML and LL responses were partially responsible for the increased body sway in patients because the initial forward (destabilizing) displacement of the CFP was increased, while the subsequent backward displacement of the CFP (a measure of the corrective braking action of LL responses) was delayed. Abnormal late automatic or possibly more voluntary postural corrections also contributed substantially to the increased body sway. During the on phase, ML amplitudes were reduced in patients but remained increased compared with controls. LL amplitudes no longer differed between both groups due to a modest, possibly dopamine-related increase in patients and a simultaneous decrease in controls. The abnormal CFP displacement was only partially improved by dopaminergic medication. The later postural corrections were not improved at all. Consequently, the increased posterior COG displacement was not ameliorated during the on phase. We conclude that (a) a combination of abnormal automatic and perhaps more voluntary postural corrections contributes to increased body sway in PD and (b) dopaminergic medication fails to improve balance impairment in PD because early automatic postural responses are only partially corrected, while later occurring postural corrections are not improved at all. These electrophysiological results support clinical observations and suggest that nondopaminergic lesions play a significant role in the pathophysiology of postural abnormalities in PD.

  14. Can medical students recognize depression? A survey at the Zagreb School of Medicine.

    PubMed

    Kuzman, Martina Rojnic; Bosnjak, Dina; Vokal, Petra; Kuharic, Josip; Brkic, Ivana; Kuzman, Tomislav; Dujmovic, Josip

    2014-06-01

    The objective of this study was to investigate medical students' knowledge and attitudes towards depression. Students attending their final year at Zagreb School of Medicine completed a set of standardized questionnaires, including attitudes towards psychiatric medication, attitudes towards depression, and personality inventory. In total, 199 students completed the questionnaire (response rate 77 %). Most medical students were only partially able to correctly identify major symptoms of depression, but did suggest referral to mental health specialists as the most appropriate course of action. They recognized social and biological causes of depression. Degree of correct identification of symptoms of depression correlated positively with non-stigmatizing attitudes towards depression and negatively with stigmatizing attitudes towards depression. Students' attitudes toward depression may influence their recognition of symptoms of depression. Incorporation of these findings in development of undergraduate medical curricula may improve students' recognition of depression.

  15. Diffusion scrubber-ion chromatography for the measurement of trace levels of atmospheric HCl

    NASA Astrophysics Data System (ADS)

    Lindgren, Per F.

    A diffusion scrubber-ion chromatographic (DS-IC) instrument has been characterized and employed for the measurement of trace levels of gaseous HCl in the atmosphere. The instrument operates with a temporal resolution of 5 min and the detection limit is estimated to be 5 pptv. Collection efficiencies for HCl with two identical diffusion scrubbers were 28±2% and 20±2%, respectively, at a sampling flow rate of 2 SLPM. Instrument response decreases with increased relative humidity. An equation, correction factor=2.45 × 10 -7 × %r.h 3 + 1.00, is used to correct for the relative humidity dependency. The instrument was tested in ambient air studies by measuring background mixing ratios between 0.02 and 0.5 ppbv at a suburban sampling site. Calibration of the instrument was carried out with a novel source of gaseous HCl based on sublimation of ammonium chloride.

  16. Optimizing the rapid measurement of detection thresholds in infants

    PubMed Central

    Jones, Pete R.; Kalwarowsky, Sarah; Braddick, Oliver J.; Atkinson, Janette; Nardini, Marko

    2015-01-01

    Accurate measures of perceptual threshold are difficult to obtain in infants. In a clinical context, the challenges are particularly acute because the methods must yield meaningful results quickly and within a single individual. The present work considers how best to maximize speed, accuracy, and reliability when testing infants behaviorally and suggests some simple principles for improving test efficiency. Monte Carlo simulations, together with empirical (visual acuity) data from 65 infants, are used to demonstrate how psychophysical methods developed with adults can produce misleading results when applied to infants. The statistical properties of an effective clinical infant test are characterized, and based on these, it is shown that (a) a reduced (false-positive) guessing rate can greatly increase test efficiency, (b) the ideal threshold to target is often below 50% correct, and (c) simply taking the max correct response can often provide the best measure of an infant's perceptual sensitivity. PMID:26237298

  17. Biased lineup instructions and face identification from video images.

    PubMed

    Thompson, W Burt; Johnson, Jaime

    2008-01-01

    Previous eyewitness memory research has shown that biased lineup instructions reduce identification accuracy, primarily by increasing false-positive identifications in target-absent lineups. Because some attempts at identification do not rely on a witness's memory of the perpetrator but instead involve matching photos to images on surveillance video, the authors investigated the effects of biased instructions on identification accuracy in a matching task. In Experiment 1, biased instructions did not affect the overall accuracy of participants who used video images as an identification aid, but nearly all correct decisions occurred with target-present photo spreads. Both biased and unbiased instructions resulted in high false-positive rates. In Experiment 2, which focused on video-photo matching accuracy with target-absent photo spreads, unbiased instructions led to more correct responses (i.e., fewer false positives). These findings suggest that investigators should not relax precautions against biased instructions when people attempt to match photos to an unfamiliar person recorded on video.

  18. Empirical Storm-Time Correction to the International Reference Ionosphere Model E-Region Electron and Ion Density Parameterizations Using Observations from TIMED/SABER

    NASA Technical Reports Server (NTRS)

    Mertens, Christoper J.; Winick, Jeremy R.; Russell, James M., III; Mlynczak, Martin G.; Evans, David S.; Bilitza, Dieter; Xu, Xiaojing

    2007-01-01

    The response of the ionospheric E-region to solar-geomagnetic storms can be characterized using observations of infrared 4.3 micrometers emission. In particular, we utilize nighttime TIMED/SABER measurements of broadband 4.3 micrometers limb emission and derive a new data product, the NO+(v) volume emission rate, which is our primary observation-based quantity for developing an empirical storm-time correction the IRI E-region electron density. In this paper we describe our E-region proxy and outline our strategy for developing the empirical storm model. In our initial studies, we analyzed a six day storm period during the Halloween 2003 event. The results of this analysis are promising and suggest that the ap-index is a viable candidate to use as a magnetic driver for our model.

  19. Visitor and community survey results for Prime Hook National Wildlife Refuge: Completion report

    USGS Publications Warehouse

    Sexton, Natalie R.; Stewart, Susan C.; Koontz, Lynne; Ponds, Phadrea; Walters, Katherine D.

    2007-01-01

    Community residents’ perceptions and opinions Data for this study were collected using a survey administered to visitors to Prime Hook NWR and individuals living in the communities surrounding the Refuge. Surveys were randomly distributed to both consumptive and nonconsumptive use visitors over a one year period (September 2004 to September 2005) to account for seasonal variation in Refuge use. Three hundred thirty-two visitor surveys were returned for a response rate of 80 percent with a confidence interval of ± 5.4. Surveys were also distributed to a stratified random sample of community members in adjacent and surrounding areas (Slaughter Beach, Broadkill Beach, Prime Hook Beach, Milton, Lewes, Milford, and surrounding communities). Four hundred ninety-one surveys from the overall community sample were returned for a response rate of 39 percent with a ± 4.4 confidence interval. Community member results were weighted by U.S. Census Bureau data to correct for age and gender bias, and for community proportionality.

  20. Some direct and generalized effects of replacing an autistic man's echolalia with correct responses to questions.

    PubMed

    McMorrow, M J; Foxx, R M

    1986-01-01

    We extended the use of operant procedures to decrease immediate echolalia and increase the appropriate responding to questions of a 21-year-old autistic man. Three experiments were conducted in which the overall plan was to encourage the subject to remain quiet before, during, and after the presentation of questions and teach him to use environmental cues (i.e., word cards or a model's responses) to increase the likelihood of responding correctly. Multiple baseline designs demonstrated that echolalia was rapidly replaced with correct stimulus-specific responses. In addition, there were a variety of generalized improvements in the subject's verbal responses to questions. The procedures and results are contrasted to previous research in an attempt to explain the encouraging findings.

  1. A method for determining the actual rate of orientation switching of DNA self-assembled monolayers using optical and electrochemical frequency response analysis.

    PubMed

    Casanova-Moreno, J; Bizzotto, D

    2015-02-17

    Electrostatic control of the orientation of fluorophore-labeled DNA strands immobilized on an electrode surface has been shown to be an effective bioanalytical tool. Modulation techniques and later time-resolved measurements were used to evaluate the kinetics of the switching between lying and standing DNA conformations. These measurements, however, are the result of a convolution between the DNA "switching" response time and the other frequency limited responses in the measurement. In this work, a method for analyzing the response of a potential driven DNA sensor is presented by calculating the potential effectively dropped across the electrode interface (using electrochemical impedance spectroscopy) as opposed to the potential applied to the electrochemical cell. This effectively deconvolutes the effect of the charging time on the observed frequency response. The corrected response shows that DNA is able to switch conformation faster than previously reported using modulation techniques. This approach will ensure accurate measurements independent of the electrochemical system, removing the uncertainty in the analysis of the switching response, enabling comparison between samples and measurement systems.

  2. Feeding on Multiple Sources: Towards a Universal Parameterization of the Functional Response of a Generalist Predator Allowing for Switching

    PubMed Central

    Morozov, Andrew; Petrovskii, Sergei

    2013-01-01

    Understanding of complex trophic interactions in ecosystems requires correct descriptions of the rate at which predators consume a variety of different prey species. Field and laboratory data on multispecies communities are rarely sufficient and usually cannot provide an unambiguous test for the theory. As a result, the conventional way of constructing a multi-prey functional response is speculative, and often based on assumptions that are difficult to verify. Predator responses allowing for prey selectivity and active switching are thought to be more biologically relevant compared to the standard proportion-based consumption. However, here we argue that the functional responses with switching may not be applicable to communities with a broad spectrum of resource types. We formulate a set of general rules that a biologically sound parameterization of a predator functional response should satisfy, and show that all existing formulations for the multispecies response with prey selectivity and switching fail to do so. Finally, we propose a universal framework for parameterization of a multi-prey functional response by combining patterns of food selectivity and proportion-based feeding. PMID:24086356

  3. Extraction of spatiotemporal response information from sorption-based cross-reactive sensor arrays for the identification and quantification of analyte mixtures

    NASA Astrophysics Data System (ADS)

    Woodka, Marc D.; Brunschwig, Bruce S.; Lewis, Nathan S.

    2008-03-01

    Linear sensor arrays made from small molecule/carbon black composite chemiresistors placed in a low headspace volume chamber, with vapor delivered at low flow rates, allowed for the extraction of chemical information that significantly increased the ability of the sensor arrays to identify vapor mixture components and to quantify their concentrations. Each sensor sorbed vapors from the gas stream to various degrees. Similar to gas chromatography, species having high vapor pressures were separated from species having low vapor pressures. Instead of producing typical sensor responses representative of thermodynamic equilibrium between each sensor and an unchanging vapor phase, sensor responses varied depending on the position of the sensor in the chamber and the time from the beginning of the analyte exposure. This spatiotemporal (ST) array response provided information that was a function of time as well as of the position of the sensor in the chamber. The responses to pure analytes and to multi-component analyte mixtures comprised of hexane, decane, ethyl acetate, chlorobenzene, ethanol, and/or butanol, were recorded along each of the sensor arrays. Use of a non-negative least squares (NNLS) method for analysis of the ST data enabled the correct identification and quantification of the composition of 2-, 3-, 4- and 5-component mixtures from arrays using only 4 chemically different sorbent films and sensor training on pure vapors only. In contrast, when traditional time- and position-independent sensor response information was used, significant errors in mixture identification were observed. The ability to correctly identify and quantify constituent components of vapor mixtures through the use of such ST information significantly expands the capabilities of such broadly cross-reactive arrays of sensors.

  4. Decomposed Photo Response Non-Uniformity for Digital Forensic Analysis

    NASA Astrophysics Data System (ADS)

    Li, Yue; Li, Chang-Tsun

    The last few years have seen the applications of Photo Response Non-Uniformity noise (PRNU) - a unique stochastic fingerprint of image sensors, to various types of digital forensic investigations such as source device identification and integrity verification. In this work we proposed a new way of extracting PRNU noise pattern, called Decomposed PRNU (DPRNU), by exploiting the difference between the physical andartificial color components of the photos taken by digital cameras that use a Color Filter Array for interpolating artificial components from physical ones. Experimental results presented in this work have shown the superiority of the proposed DPRNU to the commonly used version. We also proposed a new performance metrics, Corrected Positive Rate (CPR) to evaluate the performance of the common PRNU and the proposed DPRNU.

  5. Annoyance due to simulated blade-slap noise

    NASA Technical Reports Server (NTRS)

    Powell, C. A.

    1978-01-01

    The effects of several characteristics of blade slap noise on annoyance response were studied. These characteristics or parameters were the sound pressure level of the continuous noise used to simulate helicopter broadband noise, the ratio of impulse peak to broadband noise or crest factor, the number of pressure excursions comprising an impulse event, the rise and fall time of the individual impulses, and the repetition frequency of the impulses. Analyses were conducted to determine the correlation between subjective response and various physical measures for the range of parameters studied. A small but significant improvement in the predictive ability of PNL was provided by an A-weighted crest factor correlation. No significant improvement in predictive ability was provided by a rate correction.

  6. Shockless spalling damage of alumina ceramic

    NASA Astrophysics Data System (ADS)

    Erzar, B.; Buzaud, E.

    2012-05-01

    Ceramic materials are commonly used to build multi-layer armour. However reliable test data is needed to identify correctly models and to be able to perform accurate numerical simulation of the dynamic response of armour systems. In this work, isentropic loading waves have been applied to alumina samples to induce spalling damage. The technique employed allows assessing carefully the strain-rate at failure and the dynamic strength. Moreover, specimens have been recovered and analysed using SEM. In a damaged but unbroken specimen, interactions between cracks has been highlighted illustrating the fragmentation process.

  7. 9 CFR 417.3 - Corrective actions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 9 Animals and Animal Products 2 2011-01-01 2011-01-01 false Corrective actions. 417.3 Section 417... ANALYSIS AND CRITICAL CONTROL POINT (HACCP) SYSTEMS § 417.3 Corrective actions. (a) The written HACCP plan shall identify the corrective action to be followed in response to a deviation from a critical limit...

  8. Active self-correction of spinal posture in pain-free women in response to the command "straighten your back".

    PubMed

    Barczyk-Pawelec, Katarzyna; Sipko, Tomasz

    2017-10-01

    Evidence is limited regarding the regional changes in spinal posture after self-correction. The aim of the present study was to evaluate whether active self-correction improved standing and sitting spinal posture. Photogrammetry was used to assess regional spinal curvatures and vertical global spine orientation (GSO) in 42 asymptotic women aged 20-24 years. Upper thoracic spine angle and GSO increased in response to self-correction, while the thoracolumbar and lumbosacral angles decreased. Self-correction in the standing position resulted in decreased inclination of the upper thoracic and thoracolumbar spinal angles. Correction of sitting posture reduced the angle of the upper thoracic spine and GSO. The effects of active self-correction on spinal curvature and GSO were different for the standing versus sitting position; the greatest effects of active correction were noted in the thoracic spine. Balanced and lordotic postures were most prevalent in the habitual and actively self-corrected standing positions, whereas the kyphotic posture was most prevalent in the habitual sitting position, indicative that self-correction back posture in the standing position could be an important health-related daily activity, especially during prolonged sitting.

  9. "None of the above" as a correct and incorrect alternative on a multiple-choice test: implications for the testing effect.

    PubMed

    Odegard, Timothy N; Koen, Joshua D

    2007-11-01

    Both positive and negative testing effects have been demonstrated with a variety of materials and paradigms (Roediger & Karpicke, 2006b). The present series of experiments replicate and extend the research of Roediger and Marsh (2005) with the addition of a "none-of-the-above" response option. Participants (n=32 in both experiments) read a set of passages, took an initial multiple-choice test, completed a filler task, and then completed a final cued-recall test (Experiment 1) or multiple-choice test (Experiment 2). Questions were manipulated on the initial multiple-choice test by adding a "none-of-the-above" response alternative (choice "E") that was incorrect ("E" Incorrect) or correct ("E" Correct). The results from both experiments demonstrated that the positive testing effect was negated when the "none-of-the-above" alternative was the correct response on the initial multiple-choice test, but was still present when the "none-of-the-above" alternative was an incorrect response.

  10. Reconstructing the calibrated strain signal in the Advanced LIGO detectors

    NASA Astrophysics Data System (ADS)

    Viets, A. D.; Wade, M.; Urban, A. L.; Kandhasamy, S.; Betzwieser, J.; Brown, Duncan A.; Burguet-Castell, J.; Cahillane, C.; Goetz, E.; Izumi, K.; Karki, S.; Kissel, J. S.; Mendell, G.; Savage, R. L.; Siemens, X.; Tuyenbayev, D.; Weinstein, A. J.

    2018-05-01

    Advanced LIGO’s raw detector output needs to be calibrated to compute dimensionless strain h(t) . Calibrated strain data is produced in the time domain using both a low-latency, online procedure and a high-latency, offline procedure. The low-latency h(t) data stream is produced in two stages, the first of which is performed on the same computers that operate the detector’s feedback control system. This stage, referred to as the front-end calibration, uses infinite impulse response (IIR) filtering and performs all operations at a 16 384 Hz digital sampling rate. Due to several limitations, this procedure currently introduces certain systematic errors in the calibrated strain data, motivating the second stage of the low-latency procedure, known as the low-latency gstlal calibration pipeline. The gstlal calibration pipeline uses finite impulse response (FIR) filtering to apply corrections to the output of the front-end calibration. It applies time-dependent correction factors to the sensing and actuation components of the calibrated strain to reduce systematic errors. The gstlal calibration pipeline is also used in high latency to recalibrate the data, which is necessary due mainly to online dropouts in the calibrated data and identified improvements to the calibration models or filters.

  11. Temperature effects on pitfall catches of epigeal arthropods: a model and method for bias correction.

    PubMed

    Saska, Pavel; van der Werf, Wopke; Hemerik, Lia; Luff, Martin L; Hatten, Timothy D; Honek, Alois; Pocock, Michael

    2013-02-01

    Carabids and other epigeal arthropods make important contributions to biodiversity, food webs and biocontrol of invertebrate pests and weeds. Pitfall trapping is widely used for sampling carabid populations, but this technique yields biased estimates of abundance ('activity-density') because individual activity - which is affected by climatic factors - affects the rate of catch. To date, the impact of temperature on pitfall catches, while suspected to be large, has not been quantified, and no method is available to account for it. This lack of knowledge and the unavailability of a method for bias correction affect the confidence that can be placed on results of ecological field studies based on pitfall data.Here, we develop a simple model for the effect of temperature, assuming a constant proportional change in the rate of catch per °C change in temperature, r , consistent with an exponential Q 10 response to temperature. We fit this model to 38 time series of pitfall catches and accompanying temperature records from the literature, using first differences and other detrending methods to account for seasonality. We use meta-analysis to assess consistency of the estimated parameter r among studies.The mean rate of increase in total catch across data sets was 0·0863 ± 0·0058 per °C of maximum temperature and 0·0497 ± 0·0107 per °C of minimum temperature. Multiple regression analyses of 19 data sets showed that temperature is the key climatic variable affecting total catch. Relationships between temperature and catch were also identified at species level. Correction for temperature bias had substantial effects on seasonal trends of carabid catches. Synthesis and Applications . The effect of temperature on pitfall catches is shown here to be substantial and worthy of consideration when interpreting results of pitfall trapping. The exponential model can be used both for effect estimation and for bias correction of observed data. Correcting for temperature-related trapping bias is straightforward and enables population estimates to be more comparable. It may thus improve data interpretation in ecological, conservation and monitoring studies, and assist in better management and conservation of habitats and ecosystem services. Nevertheless, field ecologists should remain vigilant for other sources of bias.

  12. Error Correction using Quantum Quasi-Cyclic Low-Density Parity-Check(LDPC) Codes

    NASA Astrophysics Data System (ADS)

    Jing, Lin; Brun, Todd; Quantum Research Team

    Quasi-cyclic LDPC codes can approach the Shannon capacity and have efficient decoders. Manabu Hagiwara et al., 2007 presented a method to calculate parity check matrices with high girth. Two distinct, orthogonal matrices Hc and Hd are used. Using submatrices obtained from Hc and Hd by deleting rows, we can alter the code rate. The submatrix of Hc is used to correct Pauli X errors, and the submatrix of Hd to correct Pauli Z errors. We simulated this system for depolarizing noise on USC's High Performance Computing Cluster, and obtained the block error rate (BER) as a function of the error weight and code rate. From the rates of uncorrectable errors under different error weights we can extrapolate the BER to any small error probability. Our results show that this code family can perform reasonably well even at high code rates, thus considerably reducing the overhead compared to concatenated and surface codes. This makes these codes promising as storage blocks in fault-tolerant quantum computation. Error Correction using Quantum Quasi-Cyclic Low-Density Parity-Check(LDPC) Codes.

  13. The solar cycle variation of the rates of CMEs and related activity

    NASA Technical Reports Server (NTRS)

    Webb, David F.

    1991-01-01

    Coronal mass ejections (CMEs) are an important aspect of the physics of the corona and heliosphere. This paper presents results of a study of occurrence frequencies of CMEs and related activity tracers over more than a complete solar activity cycle. To properly estimate occurrence rates, observed CME rates must be corrected for instrument duty cycles, detection efficiencies away from the skyplane, mass detection thresholds, and geometrical considerations. These corrections are evaluated using CME data from 1976-1989 obtained with the Skylab, SMM and SOLWIND coronagraphs and the Helios-2 photometers. The major results are: (1) the occurrence rate of CMEs tends to track the activity cycle in both amplitude and phase; (2) the corrected rates from different instruments are reasonably consistent; and (3) over the long term, no one class of solar activity tracer is better correlated with CME rate than any other (with the possible exception of type II bursts).

  14. 45 CFR 284.45 - What are the contents and duration of the corrective action plan?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... POVERTY RATE IS THE RESULT OF THE TANF PROGRAM § 284.45 What are the contents and duration of the... manner in which the State or Territory will reduce its child poverty rate; (2) A description of the... corrective action plan until it determines and notifies us that its child poverty rate, as determined in...

  15. 45 CFR 284.45 - What are the contents and duration of the corrective action plan?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... POVERTY RATE IS THE RESULT OF THE TANF PROGRAM § 284.45 What are the contents and duration of the... manner in which the State or Territory will reduce its child poverty rate; (2) A description of the... corrective action plan until it determines and notifies us that its child poverty rate, as determined in...

  16. 45 CFR 284.45 - What are the contents and duration of the corrective action plan?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... POVERTY RATE IS THE RESULT OF THE TANF PROGRAM § 284.45 What are the contents and duration of the... manner in which the State or Territory will reduce its child poverty rate; (2) A description of the... corrective action plan until it determines and notifies us that its child poverty rate, as determined in...

  17. 45 CFR 284.45 - What are the contents and duration of the corrective action plan?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... POVERTY RATE IS THE RESULT OF THE TANF PROGRAM § 284.45 What are the contents and duration of the... manner in which the State or Territory will reduce its child poverty rate; (2) A description of the... corrective action plan until it determines and notifies us that its child poverty rate, as determined in...

  18. 45 CFR 284.45 - What are the contents and duration of the corrective action plan?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... POVERTY RATE IS THE RESULT OF THE TANF PROGRAM § 284.45 What are the contents and duration of the... manner in which the State or Territory will reduce its child poverty rate; (2) A description of the... corrective action plan until it determines and notifies us that its child poverty rate, as determined in...

  19. Induction log responses to layered, dipping, and anisotropic formations: Induction log shoulder-bed corrections to anisotropic formations and the effect of shale anisotropy in thinly laminated sand/shale sequences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hagiwara, Teruhiko

    1996-12-31

    Induction log responses to layered, dipping, and anisotropic formations are examined analytically. The analytical model is especially helpful in understanding induction log responses to thinly laminated binary formations, such as sand/shale sequences, that exhibit macroscopically anisotropic: resistivity. Two applications of the analytical model are discussed. In one application we examine special induction log shoulder-bed corrections for use when thin anisotropic beds are encountered. It is known that thinly laminated sand/shale sequences act as macroscopically anisotropic: formations. Hydrocarbon-bearing formations also act as macroscopically anisotropic formations when they consist of alternating layers of different grain-size distributions. When such formations are thick, inductionmore » logs accurately read the macroscopic conductivity, from which the hydrocarbon saturation in the formations can be computed. When the laminated formations are not thick, proper shoulder-bed corrections (or thin-bed corrections) should be applied to obtain the true macroscopic formation conductivity and to estimate the hydrocarbon saturation more accurately. The analytical model is used to calculate the thin-bed effect and to evaluate the shoulder-bed corrections. We will show that the formation resistivity and hence the hydrocarbon saturation are greatly overestimated when the anisotropy effect is not accounted for and conventional shoulder-bed corrections are applied to the log responses from such laminated formations.« less

  20. Systematic investigation of NLTE phenomena in the limit of small departures from LTE

    NASA Astrophysics Data System (ADS)

    Libby, S. B.; Graziani, F. R.; More, R. M.; Kato, T.

    1997-04-01

    In this paper, we begin a systematic study of Non-Local Thermal Equilibrium (NLTE) phenomena in near equilibrium (LTE) high energy density, highly radiative plasmas. It is shown that the principle of minimum entropy production rate characterizes NLTE steady states for average atom rate equations in the case of small departures form LTE. With the aid of a novel hohlraum-reaction box thought experiment, we use the principles of minimum entropy production and detailed balance to derive Onsager reciprocity relations for the NLTE responses of a near equilibrium sample to non-Planckian perturbations in different frequency groups. This result is a significant symmetry constraint on the linear corrections to Kirchoff's law. We envisage applying our strategy to a number of test problems which include: the NLTE corrections to the ionization state of an ion located near the edge of an otherwise LTE medium; the effect of a monochromatic radiation field perturbation on an LTE medium; the deviation of Rydberg state populations from LTE in recombining or ionizing plasmas; multi-electron temperature models such as that of Busquet; and finally, the effect of NLTE population shifts on opacity models.

  1. Randomized, Prospective, Three-Arm Study to Confirm the Auditory Safety and Efficacy of Artemether-Lumefantrine in Colombian Patients with Uncomplicated Plasmodium falciparum Malaria

    PubMed Central

    Carrasquilla, Gabriel; Barón, Clemencia; Monsell, Edwin M.; Cousin, Marc; Walter, Verena; Lefèvre, Gilbert; Sander, Oliver; Fisher, Laurel M.

    2012-01-01

    The safety of artemether-lumefantrine in patients with acute, uncomplicated Plasmodium falciparum malaria was investigated prospectively using the auditory brainstem response (ABR) and pure-tone thresholds. Secondary outcomes included polymerase chain reaction-corrected cure rates. Patients were randomly assigned in a 3:1:1 ratio to either artemether-lumefantrine (N = 159), atovaquone-proguanil (N = 53), or artesunate-mefloquine (N = 53). The null hypothesis (primary outcome), claiming that the percentage of patients with a baseline to Day-7 ABR Wave III latency increase of > 0.30 msec is ≥ 15% after administration of artemether-lumefantrine, was rejected; 2.6% of patients (95% confidence interval: 0.7–6.6) exceeded 0.30 msec, i.e., significantly below 15% (P < 0.0001). A model-based analysis found no apparent relationship between drug exposure and ABR change. In all three groups, average improvements (2–4 dB) in pure-tone thresholds were observed, and polymerase chain reaction-corrected cure rates were > 95% to Day 42. The results support the continued safe and efficacious use of artemether-lumefantrine in uncomplicated falciparum malaria. PMID:22232454

  2. Randomized, prospective, three-arm study to confirm the auditory safety and efficacy of artemether-lumefantrine in Colombian patients with uncomplicated Plasmodium falciparum malaria.

    PubMed

    Carrasquilla, Gabriel; Barón, Clemencia; Monsell, Edwin M; Cousin, Marc; Walter, Verena; Lefèvre, Gilbert; Sander, Oliver; Fisher, Laurel M

    2012-01-01

    The safety of artemether-lumefantrine in patients with acute, uncomplicated Plasmodium falciparum malaria was investigated prospectively using the auditory brainstem response (ABR) and pure-tone thresholds. Secondary outcomes included polymerase chain reaction-corrected cure rates. Patients were randomly assigned in a 3:1:1 ratio to either artemether-lumefantrine (N = 159), atovaquone-proguanil (N = 53), or artesunate-mefloquine (N = 53). The null hypothesis (primary outcome), claiming that the percentage of patients with a baseline to Day-7 ABR Wave III latency increase of > 0.30 msec is ≥ 15% after administration of artemether-lumefantrine, was rejected; 2.6% of patients (95% confidence interval: 0.7-6.6) exceeded 0.30 msec, i.e., significantly below 15% (P < 0.0001). A model-based analysis found no apparent relationship between drug exposure and ABR change. In all three groups, average improvements (2-4 dB) in pure-tone thresholds were observed, and polymerase chain reaction-corrected cure rates were > 95% to Day 42. The results support the continued safe and efficacious use of artemether-lumefantrine in uncomplicated falciparum malaria.

  3. Acute effects of Dry Immersion on kinematic characteristics of postural corrective responses

    NASA Astrophysics Data System (ADS)

    Sayenko, D. G.; Miller, T. F.; Melnik, K. A.; Netreba, A. I.; Khusnutdinova, D. R.; Kitov, V. V.; Tomilovskaya, E. S.; Reschke, M. F.; Gerasimenko, Y. P.; Kozlovskaya, I. B.

    2016-04-01

    Impairments in balance control are inevitable following exposure to microgravity. However, the role of particular sensory system in postural disorders at different stages of the exposure to microgravity still remains unknown. We used a method called Dry Immersion (DI), as a ground-based model of microgravity, to elucidate the effects of 6-h of load-related afferent inputs on kinematic characteristics of postural corrective responses evoked by pushes to the chest of different intensities during upright standing. The structure of postural corrective responses was altered following exposure to DI, which was manifested by: (1) an increase of the ankle and knee flexion during perturbations of medium intensity, (2) the lack of the compensatory hip extension, as well as diminished knee and ankle flexion with a further increase of the perturbation intensity to submaximal level. We suggest that the lack of weight-bearing increases the reactivity of the balance control system, whereas the ability to scale the responses proportionally to the perturbation intensity decreases. Disrupted neuromuscular coordination of postural corrective responses following DI can be attributed to adaptive neural modifications on the spinal and cortical levels. The present study provides evidence that even a short-term lack of load-related afferent inputs alters kinematic patterns of postural corrective responses, and can result in decreased balance control. Because vestibular input is not primarily affected during the DI exposure, our results indicate that activity and the state of the load-related afferents play critical roles in balance control following real or simulated microgravity.

  4. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy.

    PubMed

    Bruza, Petr; Gollub, Sarah L; Andreozzi, Jacqueline M; Tendler, Irwin I; Williams, Benjamin B; Jarvis, Lesley A; Gladstone, David J; Pogue, Brian W

    2018-05-02

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  5. Time-gated scintillator imaging for real-time optical surface dosimetry in total skin electron therapy

    NASA Astrophysics Data System (ADS)

    Bruza, Petr; Gollub, Sarah L.; Andreozzi, Jacqueline M.; Tendler, Irwin I.; Williams, Benjamin B.; Jarvis, Lesley A.; Gladstone, David J.; Pogue, Brian W.

    2018-05-01

    The purpose of this study was to measure surface dose by remote time-gated imaging of plastic scintillators. A novel technique for time-gated, intensified camera imaging of scintillator emission was demonstrated, and key parameters influencing the signal were analyzed, including distance, angle and thickness. A set of scintillator samples was calibrated by using thermo-luminescence detector response as reference. Examples of use in total skin electron therapy are described. The data showed excellent room light rejection (signal-to-noise ratio of scintillation SNR  ≈  470), ideal scintillation dose response linearity, and 2% dose rate error. Individual sample scintillation response varied by 7% due to sample preparation. Inverse square distance dependence correction and lens throughput error (8% per meter) correction were needed. At scintillator-to-source angle and observation angle  <50°, the radiant energy fluence error was smaller than 1%. The achieved standard error of the scintillator cumulative dose measurement compared to the TLD dose was 5%. The results from this proof-of-concept study documented the first use of small scintillator targets for remote surface dosimetry in ambient room lighting. The measured dose accuracy renders our method to be comparable to thermo-luminescent detector dosimetry, with the ultimate realization of accuracy likely to be better than shown here. Once optimized, this approach to remote dosimetry may substantially reduce the time and effort required for surface dosimetry.

  6. Application of Al2O3:C+fibre dosimeters for 290 MeV/n carbon therapeustic beam dosimetry.

    NASA Astrophysics Data System (ADS)

    Nascimento, L. F.; Vanhavere, F.; Kodaira, S.; Kitamura, H.; Verellen, D.; De Deene, Y.

    2015-10-01

    The capability of radioluminescence (RL) dosimeters composed of carbon-doped aluminium oxide (Al2O3:C) detectors+optical fibre has been verified for absorbed dose-rate measurements during carbon radiotherapy. The RL signals from two separate Al2O3:C detectors (single crystal 'CG' and droplet 'P1') have been systematically measured and compared along the Bragg-curve and Spread-Out Bragg-Peak of 290 MeV/n carbon beams in the water. The absorbed dose response was assessed for the range of 0.5-10 Gy. For doses up to 6 Gy, we observed a linear response for both types of detectors, while for higher doses CG presented a more prominent supraliearity than P1. The RL response for low-LET protons in the entrance from the curve was found to closely resemble that observed for a clinical 6 MV X-ray beam, while it was found that P1 has a better agreement with the reference data from standard ionization chamber than CG. We observed a significant decrease in luminescence efficiency with LET in the Bragg peak region. The Al2O3:C RL luminescence efficiency differs from Al2O3:C OSL results, which implies that the signal can be corrected for LET dependency to match the correct SOBP and Bragg Peak.

  7. Efficacy of Error for the Correction of Initially Incorrect Assumptions and of Feedback for the Affirmation of Correct Responding: Learning in the Classroom

    ERIC Educational Resources Information Center

    Brosvic, Gary M.; Epstein, Michael L.; Cook, Michael J.; Dihoff, Roberta E.

    2005-01-01

    Participants completed 5 classroom examinations during which the timing of knowledge of results (no feedback: Scantron form; delayed feedback: end-of-test, 24 hour delay; immediate feedback: educator, response form) and iterative responding (1 response, up to 4 responses) were manipulated. At the end of the semester, each participant completed a…

  8. Modeling Sea-Level Change using Errors-in-Variables Integrated Gaussian Processes

    NASA Astrophysics Data System (ADS)

    Cahill, Niamh; Parnell, Andrew; Kemp, Andrew; Horton, Benjamin

    2014-05-01

    We perform Bayesian inference on historical and late Holocene (last 2000 years) rates of sea-level change. The data that form the input to our model are tide-gauge measurements and proxy reconstructions from cores of coastal sediment. To accurately estimate rates of sea-level change and reliably compare tide-gauge compilations with proxy reconstructions it is necessary to account for the uncertainties that characterize each dataset. Many previous studies used simple linear regression models (most commonly polynomial regression) resulting in overly precise rate estimates. The model we propose uses an integrated Gaussian process approach, where a Gaussian process prior is placed on the rate of sea-level change and the data itself is modeled as the integral of this rate process. The non-parametric Gaussian process model is known to be well suited to modeling time series data. The advantage of using an integrated Gaussian process is that it allows for the direct estimation of the derivative of a one dimensional curve. The derivative at a particular time point will be representative of the rate of sea level change at that time point. The tide gauge and proxy data are complicated by multiple sources of uncertainty, some of which arise as part of the data collection exercise. Most notably, the proxy reconstructions include temporal uncertainty from dating of the sediment core using techniques such as radiocarbon. As a result of this, the integrated Gaussian process model is set in an errors-in-variables (EIV) framework so as to take account of this temporal uncertainty. The data must be corrected for land-level change known as glacio-isostatic adjustment (GIA) as it is important to isolate the climate-related sea-level signal. The correction for GIA introduces covariance between individual age and sea level observations into the model. The proposed integrated Gaussian process model allows for the estimation of instantaneous rates of sea-level change and accounts for all available sources of uncertainty in tide-gauge and proxy-reconstruction data. Our response variable is sea level after correction for GIA. By embedding the integrated process in an errors-in-variables (EIV) framework, and removing the estimate of GIA, we can quantify rates with better estimates of uncertainty than previously possible. The model provides a flexible fit and enables us to estimate rates of change at any given time point, thus observing how rates have been evolving from the past to present day.

  9. Reduced response to reward in smokers and cannabis users.

    PubMed

    Martin-Soelch, Chantal; Kobel, Maja; Stoecklin, Markus; Michael, Tanja; Weber, Simone; Krebs, Bigna; Opwis, Klaus

    2009-01-01

    Cannabis is one of the most commonly used illicit drugs. Reduced neural and behavioral reactions to reward have been demonstrated in other forms of addiction, as expressed by reduced mood reactivity and lack of striatal activation to rewards, but this effect has not yet been investigated in cannabis users. We hypothesized that cannabis users and tobacco smokers would evidence lower positive mood ratings in rewarded conditions than control participants and that this reduction would be greater in cannabis users than in smokers. We examined the influence of reward on mood and performance in a group of regular cannabis users, a group of tobacco smokers and a group of nonsmokers while they performed a spatial recognition task with delayed response that incorporated 3 levels of difficulty. Correct responses were either not reinforced or reinforced with money. We measured the accuracy of reactions, reaction times and mood ratings throughout the trials. Cannabis users rated their mood as significantly worse than the smokers and nonsmokers during the easiest level of the rewarded condition. A significant positive correlation between mood ratings and monetary reward was found in the nonsmokers but not in the cannabis users and smokers. The groups did not differ with regard to task performance. Our results suggest that regular cannabis use affects certain aspects of motivation and that both tobacco smoking and cannabis use lead to similar motivational changes. However, the use of cannabis seems to affect motivation in a stronger way than does tobacco smoking alone. 2009 S. Karger AG, Basel

  10. [Evaluation of the level of knowledge of medical secretaries about clinical specimens].

    PubMed

    Ciftçi, Ihsan Hakki; Safak, Birol; Cetinkaya, Zafer; Aktepe, Orhan Cem; Unalan, Demet

    2006-10-01

    The rapid development of medical industry in the last 5 years in Turkey led to an increased demand for medical technicians and secretaries. The aim of this study was to evaluate the level of knowledge of students in Occupational School of Medical Documentation and Secretary about the clinical specimens, and to estimate the need for an additional education on clinical specimens. Four hundred and forty eight students from eight universities were participated to this questionnaire survey. Mean age of the participants were 20.4+/-1.66 years and 342 (76.3%) of them were female students. The mean answer rate of students to the questions about clinical specimens was found 3.4+/-1.9% (min-max: 0-10). Correct answer rates were similar for both first and second year students. There was a negative relationship between the educational year and the rate of correct answer, however the correlation was not significant. Additionally, internship period did not have any effect on the level of knowledge. The results of this survey have indicated that the level of knowledge of medical secretaries about clinical specimens was very low. As the roles and responsibilities of medical secretaries in medical industry increases, in order to increase the cost-effectivity, quality and patient satisfaction, the contents of their education programs must be reorganized, and a lecture about clinical specimens should be integrated.

  11. [Interrelations Between Adolescent Problematic Internet Use and Parental Internet Mediation].

    PubMed

    Kammerl, Rudolf; Wartberg, Lutz

    2018-02-01

    Interrelations Between Adolescent Problematic Internet Use and Parental Internet Mediation Everyday life of adolescents and their parents is increasingly characterized by digital media usage (also referred to as "process of mediatization"). In the current study, associations between problematic Internet use of the adolescents (as a possible consequence of the process of mediatization) and parental media education were explored. For this purpose, throughout Germany 1,095 family dyads (an adolescent and a related parent) were investigated with a standardized questionnaire measuring different aspects of parental media education and adolescent problematic Internet use. We conducted two multiple linear regression analyses (dimensional approach) with adolescent problematic Internet use based on self-ratings (model 1, corrected R 2 = 0.18) and parental assessment (model 2, corrected R 2 = 0.24) as response variables. Consistently for self- and parental ratings, adolescent problematic Internet use was statistically significant related to male gender (of the adolescent), a more frequent inconsistent media education (adolescents' and parents' perspective) and a stronger monitoring (parents' perspective). Additionally, we observed associations between the parental rating of adolescent problematic Internet use and a less frequent active and restrictive Internet Mediation (parents' perspective). The findings of the present study show the importance of parental media education for problematic Internet use in adolescence and especially, the role of inconsistent media education should be investigated again in further studies.

  12. Your kid could not have done that: even untutored observers can discern intentionality and structure in abstract expressionist art.

    PubMed

    Snapper, Leslie; Oranç, Cansu; Hawley-Dolan, Angelina; Nissel, Jenny; Winner, Ellen

    2015-04-01

    Can people with no special knowledge about art detect the skill, intentionality, and expressed meanings in non-representational art? Hawley-Dolan and Winner (2011) showed participants without training in art images of abstract expressionist paintings paired with superficially similar works by children or animals and asked them which they preferred and which was a better work of art. Participants selected the works by artists in response to both questions at a rate above chance. In Study 1, we used the same image pairs but asked a more direct question: which painting is by the artist rather than the child or animal? Individuals with no familiarity with abstract expressionism correctly identified the artists' works at a rate significantly above chance. In Study 2 participants saw each image singly and were asked whether it was by an artist or a child or animal. Participants unfamiliar with abstract expressionism again correctly identified the source of the works at a rate above chance. Study 3 demonstrated that this discrimination is made on the basis of perceived intentionality and perceived structure. People see more than they think they do in abstract art. These findings tell us something about the nature of non-figurative art. They also tell us something about the human tendency to ferret out intentionality. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Hawking radiation as tunneling in Schwarzschild anti-de Sitter black hole

    NASA Astrophysics Data System (ADS)

    Sefiedgar, A. S.; Ashrafinejad, A.

    2017-08-01

    The Hawking radiation from a (d+1) -dimensional Schwarzschild Anti-de Sitter (SAdS) black hole is investigated within rainbow gravity. Based on the method proposed by Kraus, Parikh and Wilczek, the Hawking radiation is considered as a tunneling process across the horizon. The emission rate of massless particles which are tunneling across the quantum-corrected horizon is calculated. Enforcing the energy conservation law leads to a dynamical geometry. Both the dynamical geometry and the quantum effects of space-time yield some corrections to the emission rate. The corrected radiation spectrum is not purely thermal. The emission rate is related to the changes of modified entropy in rainbow gravity and the corrected thermal spectrum may be consistent with an underlying unitary quantum theory. The correlations between emitted particles are also investigated in order to address the recovery of information.

  14. Influence of Heart Rate in Non-linear HRV Indices as a Sampling Rate Effect Evaluated on Supine and Standing.

    PubMed

    Bolea, Juan; Pueyo, Esther; Orini, Michele; Bailón, Raquel

    2016-01-01

    The purpose of this study is to characterize and attenuate the influence of mean heart rate (HR) on nonlinear heart rate variability (HRV) indices (correlation dimension, sample, and approximate entropy) as a consequence of being the HR the intrinsic sampling rate of HRV signal. This influence can notably alter nonlinear HRV indices and lead to biased information regarding autonomic nervous system (ANS) modulation. First, a simulation study was carried out to characterize the dependence of nonlinear HRV indices on HR assuming similar ANS modulation. Second, two HR-correction approaches were proposed: one based on regression formulas and another one based on interpolating RR time series. Finally, standard and HR-corrected HRV indices were studied in a body position change database. The simulation study showed the HR-dependence of non-linear indices as a sampling rate effect, as well as the ability of the proposed HR-corrections to attenuate mean HR influence. Analysis in a body position changes database shows that correlation dimension was reduced around 21% in median values in standing with respect to supine position ( p < 0.05), concomitant with a 28% increase in mean HR ( p < 0.05). After HR-correction, correlation dimension decreased around 18% in standing with respect to supine position, being the decrease still significant. Sample and approximate entropy showed similar trends. HR-corrected nonlinear HRV indices could represent an improvement in their applicability as markers of ANS modulation when mean HR changes.

  15. The humanitarian emergency in Burundi: evaluation of the operational strategy for management of nutritional crisis.

    PubMed

    Rossi, Laura; Verna, Daniel; Villeneuve, Susie L

    2008-07-01

    To evaluate the impact and appropriateness of programmes for the management and treatment of severe malnutrition in emergency situations. A central unified database was set up with all data and statistics provided by nutritional centres (NC) active in Burundi. The paper describes the case of Burundi as an example of the response of the humanitarian community to nutritional crisis. Since 1999, more than one million (1,054,210) severely malnourished patients were treated in NC established in Burundi. Peaks of beneficiaries were registered in 2000 and 2001; the admission rate started to decrease in 2002. In 2004, twenty therapeutic feeding centres (TFC) and 224 supplementary feeding centres (SFC) were active for the treatment of 127,420 beneficiaries. Nutritional programmes were present in every province with a coverage rate of 55%. The most convincing impact of the nutritional programme in Burundi was the reduction of mortality rate in children under 5 years of age; an impact on the prevalence of acute malnutrition could not be demonstrated. Children under 5 years old accounted for 62% of beneficiaries in TFC and 76% in SFC. TFC performance indicators fulfilled the minimum standards in disaster response; the performance of SFC was not so optimal with a low recovery rate (69% v. >80%) and a high non-respondent rate (16% v. <5%). With the combination of coverage and cure rate, the programme met 44% of the assessed needs in 2004. In Burundi the stabilisation of security conditions permitted a combination of humanitarian responses ranging from emergency activities to strengthening of community-based initiatives that could correct the coverage and impact limitations.

  16. Improving the ablation efficiency of excimer laser systems with higher repetition rates through enhanced debris removal and optimized spot pattern.

    PubMed

    Arba-Mosquera, Samuel; Klinner, Thomas

    2014-03-01

    To evaluate the reasons for the required increased radiant exposure for higher-repetition-rate excimer lasers and determine experimentally possible compensations to achieve equivalent ablation profiles maintaining the same single-pulse energies and radiant exposures for laser repetition rates ranging from 430 to 1000 Hz. Schwind eye-tech-solutions GmbH and Co. KG, Kleinostheim, Germany. Experimental study. Poly(methyl methacrylate) (PMMA) plates were photoablated. The pulse laser energy was maintained during all experiments; the effects of the flow of the debris removal, the shot pattern for the correction, and precooling the PMMA plates were evaluated in terms of achieved ablation versus repetition rate. The mean ablation performance ranged from 88% to 100%; the variability between the profile measurements ranged from 1.4% to 6.2%. Increasing the laser repetition rate from 430 Hz to 1000 Hz reduced the mean ablation performance from 98% to 91% and worsened the variability from 1.9% to 4.3%. Increasing the flow of the debris removal, precooling the PMMA plates to -18°C, and adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the variability. Only adapting the shot pattern for the thermal response of PMMA to excimer ablation helped stabilize the mean ablation performance. The ablation performance of higher-repetition-rate excimer lasers on PMMA improved with improvements in the debris removal systems and shot pattern. More powerful debris removal systems and smart shot patterns in terms of thermal response improved the performance of these excimer lasers. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  17. dAcquisition setting optimization and quantitative imaging for 124I studies with the Inveon microPET-CT system.

    PubMed

    Anizan, Nadège; Carlier, Thomas; Hindorf, Cecilia; Barbet, Jacques; Bardiès, Manuel

    2012-02-13

    Noninvasive multimodality imaging is essential for preclinical evaluation of the biodistribution and pharmacokinetics of radionuclide therapy and for monitoring tumor response. Imaging with nonstandard positron-emission tomography [PET] isotopes such as 124I is promising in that context but requires accurate activity quantification. The decay scheme of 124I implies an optimization of both acquisition settings and correction processing. The PET scanner investigated in this study was the Inveon PET/CT system dedicated to small animal imaging. The noise equivalent count rate [NECR], the scatter fraction [SF], and the gamma-prompt fraction [GF] were used to determine the best acquisition parameters for mouse- and rat-sized phantoms filled with 124I. An image-quality phantom as specified by the National Electrical Manufacturers Association NU 4-2008 protocol was acquired and reconstructed with two-dimensional filtered back projection, 2D ordered-subset expectation maximization [2DOSEM], and 3DOSEM with maximum a posteriori [3DOSEM/MAP] algorithms, with and without attenuation correction, scatter correction, and gamma-prompt correction (weighted uniform distribution subtraction). Optimal energy windows were established for the rat phantom (390 to 550 keV) and the mouse phantom (400 to 590 keV) by combining the NECR, SF, and GF results. The coincidence time window had no significant impact regarding the NECR curve variation. Activity concentration of 124I measured in the uniform region of an image-quality phantom was underestimated by 9.9% for the 3DOSEM/MAP algorithm with attenuation and scatter corrections, and by 23% with the gamma-prompt correction. Attenuation, scatter, and gamma-prompt corrections decreased the residual signal in the cold insert. The optimal energy windows were chosen with the NECR, SF, and GF evaluation. Nevertheless, an image quality and an activity quantification assessment were required to establish the most suitable reconstruction algorithm and corrections for 124I small animal imaging.

  18. Theoretical and Experimental Investigations of Coincidences in Poisson Distributed Pulse Trains and Spectral Distortion Caused by Pulse Pileup.

    NASA Astrophysics Data System (ADS)

    Bristow, Quentin

    1990-01-01

    Part one of this two-part study is concerned with the multiple coincidences in pulse trains from X-ray and gamma radiation detectors which are the cause of pulse pileup. A sequence of pulses with inter-arrival times less than tau, the resolving time of the pulse-height analysis system used to acquire spectra, is called a multiple pulse string. Such strings can be classified on the basis of the number of pulses they contain, or the number of resolving times they cover. The occurrence rates of such strings are derived from theoretical considerations. Logic circuits were devised to make experimental measurements of multiple pulse string occurrence rates in the output from a NaI(Tl) scintillation detector over a wide range of count rates. Markov process theory was used to predict state transition rates in the logic circuits, enabling the experimental data to be checked rigorously for conformity with those predicted for a Poisson distribution. No fundamental discrepancies were observed. Part two of the study is concerned with a theoretical analysis of pulse pileup and the development of a discrete correction algorithm, based on the use of a function to simulate the coincidence spectrum produced by partial sums of pulses. Monte Carlo simulations, incorporating criteria for pulse pileup inherent in the operation of modern ADC's, were used to generate pileup spectra due to coincidences between two pulses, (1st order pileup) and three pulses (2nd order pileup), for different semi-Gaussian pulse shapes. Coincidences between pulses in a single channel produced a basic probability density function spectrum which can be regarded as an impulse response for a particular pulse shape. The use of a flat spectrum (identical count rates in all channels) in the simulations, and in a parallel theoretical analysis, showed the 1st order pileup distorted the spectrum to a linear ramp with a pileup tail. The correction algorithm was successfully applied to correct entire spectra for 1st and 2nd order pileup; both those generated by Monte Carlo simulations and in addition some real spectra acquired with a laboratory multichannel analysis system.

  19. Optimized algorithm for the spatial nonuniformity correction of an imaging system based on a charge-coupled device color camera.

    PubMed

    de Lasarte, Marta; Pujol, Jaume; Arjona, Montserrat; Vilaseca, Meritxell

    2007-01-10

    We present an optimized linear algorithm for the spatial nonuniformity correction of a CCD color camera's imaging system and the experimental methodology developed for its implementation. We assess the influence of the algorithm's variables on the quality of the correction, that is, the dark image, the base correction image, and the reference level, and the range of application of the correction using a uniform radiance field provided by an integrator cube. The best spatial nonuniformity correction is achieved by having a nonzero dark image, by using an image with a mean digital level placed in the linear response range of the camera as the base correction image and taking the mean digital level of the image as the reference digital level. The response of the CCD color camera's imaging system to the uniform radiance field shows a high level of spatial uniformity after the optimized algorithm has been applied, which also allows us to achieve a high-quality spatial nonuniformity correction of captured images under different exposure conditions.

  20. Solving Upwind-Biased Discretizations: Defect-Correction Iterations

    NASA Technical Reports Server (NTRS)

    Diskin, Boris; Thomas, James L.

    1999-01-01

    This paper considers defect-correction solvers for a second order upwind-biased discretization of the 2D convection equation. The following important features are reported: (1) The asymptotic convergence rate is about 0.5 per defect-correction iteration. (2) If the operators involved in defect-correction iterations have different approximation order, then the initial convergence rates may be very slow. The number of iterations required to get into the asymptotic convergence regime might grow on fine grids as a negative power of h. In the case of a second order target operator and a first order driver operator, this number of iterations is roughly proportional to h-1/3. (3) If both the operators have the second approximation order, the defect-correction solver demonstrates the asymptotic convergence rate after three iterations at most. The same three iterations are required to converge algebraic error below the truncation error level. A novel comprehensive half-space Fourier mode analysis (which, by the way, can take into account the influence of discretized outflow boundary conditions as well) for the defect-correction method is developed. This analysis explains many phenomena observed in solving non-elliptic equations and provides a close prediction of the actual solution behavior. It predicts the convergence rate for each iteration and the asymptotic convergence rate. As a result of this analysis, a new very efficient adaptive multigrid algorithm solving the discrete problem to within a given accuracy is proposed. Numerical simulations confirm the accuracy of the analysis and the efficiency of the proposed algorithm. The results of the numerical tests are reported.

  1. Automated measurements for individualized heart rate correction of the QT interval.

    PubMed

    Mason, Jay W; Moon, Thomas E

    2015-04-01

    Subject-specific electrocardiographic QT interval correction for heart rate is often used in clinical trials with frequent electrocardiographic recordings. However, in these studies relatively few 10-s, 12-lead electrocardiograms may be available for calculating the individual correction. Highly automated QT and RR measurement tools have made it practical to measure electrocardiographic intervals on large volumes of continuous electrocardiogram data. The purpose of this study was to determine whether an automated method can be used in lieu of a manual method. In 49 subjects who completed all treatments in a four-armed crossover study we compared two methods for derivation of individualized rate-correction coefficients: manual measurement on 10-s electrocardiograms and automated measurement of QT and RR during continuous 24-h electrocardiogram recordings. The four treatments, received by each subject in a latin-square randomization sequence were placebo, moxifloxacin, and two doses of an investigational drug. Analysis of continuous electrocardiogram data yielded a lower standard deviation of QT:RR regression values than the manual method, though the differences were not statistically significant. The within-subject and within-treatment coefficients of variation between the manual and automated methods were not significantly different. Corrected QT values from the two methods had similar rates of true and false positive identification of moxifloxacin's QT prolonging effect. An automated method for individualized rate correction applied to continuous electrocardiogram data could be advantageous in clinical trials, as the automated method is simpler, is based upon a much larger volume of data, yields similar results, and requires no human over-reading of the measurements. © The Author(s) 2015.

  2. [Work with visual demands. Assumption of responsibility for optical correction by the employer].

    PubMed

    Hermans, G

    2004-01-01

    Comparison of visual demands of work in a traditional office to those of work in an office equiped with a screen. Description of problems of vision when focusing the eye to various distances and fixing it in various directions. Range of possibilities for optical correction for work with a screen (monofocal, bifocal, progressive or for reading), specifying among the optical corrections those which are exclusively reserved for this activity and should become the employer's responsibility.

  3. 78 FR 15973 - Fee Rate

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-13

    ... DEPARTMENT OF THE INTERIOR National Indian Gaming Commission Fee Rate Correction In notice document 2013-05334, appearing on page 14821 in the issue of Thursday, March 7, 2013, make the following correction: On page 14821, in the second column, in the eighth line from the bottom of the page, ``Dated...

  4. Mindfulness Meditation as an Adjunct Approach to Treatment within the Correctional System

    ERIC Educational Resources Information Center

    Dafoe, Terra; Stermac, Lana

    2013-01-01

    Cognitive-behavioral therapy and relapse prevention represent the correctional gold standard in treatment, while the principles of risk, need, and responsivity are widely recognized as essential for reducing recidivism. Addressing responsivity has become difficult as the number of inmates with mental health diagnoses continues to rise,…

  5. Responsible Adult Culture (RAC): Cognitive and Behavioral Changes at a Community-Based Correctional Facility

    ERIC Educational Resources Information Center

    Devlin, Renee S.; Gibbs, John C.

    2010-01-01

    This article examined cognitive and behavioral changes among participants in Responsible Adult Culture (RAC), a cognitive-behavioral (especially, cognitive restructuring) treatment program in use at the Franklin County Community-Based Correctional Facility (CBCF). Participants were adult felony offenders (approximately three-fourths male). A…

  6. Assessment of physiological noise modelling methods for functional imaging of the spinal cord.

    PubMed

    Kong, Yazhuo; Jenkinson, Mark; Andersson, Jesper; Tracey, Irene; Brooks, Jonathan C W

    2012-04-02

    The spinal cord is the main pathway for information between the central and the peripheral nervous systems. Non-invasive functional MRI offers the possibility of studying spinal cord function and central sensitisation processes. However, imaging neural activity in the spinal cord is more difficult than in the brain. A significant challenge when dealing with such data is the influence of physiological noise (primarily cardiac and respiratory), and currently there is no standard approach to account for these effects. We have previously studied the various sources of physiological noise for spinal cord fMRI at 1.5T and proposed a physiological noise model (PNM) (Brooks et al., 2008). An alternative de-noising strategy, selective averaging filter (SAF), was proposed by Deckers et al. (2006). In this study we reviewed and implemented published physiological noise correction methods at higher field (3T) and aimed to find the optimal models for gradient-echo-based BOLD acquisitions. Two general techniques were compared: physiological noise model (PNM) and selective averaging filter (SAF), along with regressors designed to account for specific signal compartments and physiological processes: cerebrospinal fluid (CSF), motion correction (MC) parameters, heart rate (HR), respiration volume per time (RVT), and the associated cardiac and respiratory response functions. Functional responses were recorded from the cervical spinal cord of 18 healthy subjects in response to noxious thermal and non-noxious punctate stimulation. The various combinations of models and regressors were compared in three ways: the model fit residuals, regression model F-tests and the number of activated voxels. The PNM was found to outperform SAF in all three tests. Furthermore, inclusion of the CSF regressor was crucial as it explained a significant amount of signal variance in the cord and increased the number of active cord voxels. Whilst HR, RVT and MC explained additional signal (noise) variance, they were also found (in particular HR and RVT) to have a negative impact on the parameter estimates (of interest)--as they may be correlated with task conditions e.g. noxious thermal stimuli. Convolution with previously published cardiac and respiratory impulse response functions was not found to be beneficial. The other novel aspect of current study is the investigation of the influence of pre-whitening together with PNM regressors on spinal fMRI data. Pre-whitening was found to reduce non-white noise, which was not accounted for by physiological noise correction, and decrease false positive detection rates. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Some direct and generalized effects of replacing an autistic man's echolalia with correct responses to questions.

    PubMed Central

    McMorrow, M J; Foxx, R M

    1986-01-01

    We extended the use of operant procedures to decrease immediate echolalia and increase the appropriate responding to questions of a 21-year-old autistic man. Three experiments were conducted in which the overall plan was to encourage the subject to remain quiet before, during, and after the presentation of questions and teach him to use environmental cues (i.e., word cards or a model's responses) to increase the likelihood of responding correctly. Multiple baseline designs demonstrated that echolalia was rapidly replaced with correct stimulus-specific responses. In addition, there were a variety of generalized improvements in the subject's verbal responses to questions. The procedures and results are contrasted to previous research in an attempt to explain the encouraging findings. PMID:3771422

  8. SU-F-T-263: Dosimetric Characteristics of the Cine Acquisition Mode of An A-Si EPID

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bawazeer, O; Deb, P; Sarasanandarajah, S

    2016-06-15

    Purpose: To investigate the dosimetric characteristics of Varian a-Si-500 electronic portal imaging device (EPID) operated in cine mode particularly considering linearity with delivered dose, dose rate, field size, phantom thickness, MLC speed and common IMRT fields. Methods: The EPID that attached to a Varian Clinac 21iX linear accelerator, was irradiated with 6 and 18 MV using 600 MU/min. Image acquisition is controlled by the IAS3 software, Trigger delay was 6 ms, BeamOnDelay and FrameStartDelay were zero. Different frame rates were utilized. Cine mode response was calculated using MATLAB as summation of mean pixel values in a region of interest ofmore » the acquired images. The performance of cine mode was compared to integrated mode and dose measurements in water using CC13 ionization chamber. Results: Figure1 illustrates that cine mode has nonlinear response for small MU, when delivering 10 MU was about 0.5 and 0.64 for 6 and 18 MV respectively. This is because the missing acquired images that were calculated around four images missing in each delivery. With the increase MU the response became linear and comparable with integrated mode and ionization chamber within 2%. Figure 2 shows that cine mode has comparable response with integrated mode and ionization chamber within 2% with changing dose rate for 10 MU delivered. This indicates that the dose rate change has no effect on nonlinearity of cine mode response. Except nonlinearity, cine mode is well matched to integrated mode response within 2% for field size, phantom thickness, MLC speed dependences. Conclusion: Cine mode has similar dosimetric characteristics to integrated mode with open and IMRT fields, and the main limitation with cine mode is missing images. Therefore, the calibration of EPID images with this mode should be run with large MU, and when IMRT verification field has low MU, the correction for missing images are required.« less

  9. The Impact of 3-Option Responses to Multiple-Choice Questions on Guessing Strategies and Cut Score Determinations

    PubMed Central

    ROYAL, KENNETH D.; STOCKDALE, MYRAH R.

    2017-01-01

    Introduction: Research has asserted MCQ items using three response options (one correct answer with two distractors) is comparable to, and possibly preferable over, traditional MCQ item formats consisting of four response options (e.g., one correct answer with three distractors), or five response options (e.g., one correct answer with four distractors). Some medical educators have also adopted the practice of using 3-option responses on MCQ exams as a response to the difficulty experienced in generating additional plausible distractors. To date, however, little work has explored how 3-option responses might impact validity threats stemming from random guessing strategies, and what impact 3-option responses might have on cut-score determinations, particularly in the context of medical education classroom assessments. The purpose of this work is to further explore these critically important considerations that largely have gone ignored in the medical education literature to this point. Methods: A cumulative binomial distribution formula was used to calculate the probability that an examinee will answer at random a given number of items correctly on any exam (of any length). By way of a demonstration, a variety of scenarios were presented to illustrate how examination length and the number of response options impact examinees’ chances of passing a given examination, and how subsequent cut-score decisions may be impacted by these factors. Results: As a general rule, classroom assessments containing fewer items should utilize traditional 4-option or 5-option responses, whereas assessments of greater length are afforded greater flexibility in potentially utilizing 3-option responses. Conclusions: More research on items with 3-option responses is needed to better understand what value, if any, 3-option responses truly add to classroom assessments, and in what contexts potential benefits might be discernible. PMID:28367465

  10. The Impact of 3-Option Responses to Multiple-Choice Questions on Guessing Strategies and Cut Score Determinations.

    PubMed

    Royal, Kenneth D; Stockdale, Myrah R

    2017-04-01

    Research has asserted MCQ items using three response options (one correct answer with two distractors) is comparable to, and possibly preferable over, traditional MCQ item formats consisting of four response options (e.g., one correct answer with three distractors), or five response options (e.g., one correct answer with four distractors). Some medical educators have also adopted the practice of using 3-option responses on MCQ exams as a response to the difficulty experienced in generating additional plausible distractors. To date, however, little work has explored how 3-option responses might impact validity threats stemming from random guessing strategies, and what impact 3-option responses might have on cut-score determinations, particularly in the context of medical education classroom assessments. The purpose of this work is to further explore these critically important considerations that largely have gone ignored in the medical education literature to this point. A cumulative binomial distribution formula was used to calculate the probability that an examinee will answer at random a given number of items correctly on any exam (of any length). By way of a demonstration, a variety of scenarios were presented to illustrate how examination length and the number of response options impact examinees' chances of passing a given examination, and how subsequent cut-score decisions may be impacted by these factors. As a general rule, classroom assessments containing fewer items should utilize traditional 4-option or 5-option responses, whereas assessments of greater length are afforded greater flexibility in potentially utilizing 3-option responses. More research on items with 3-option responses is needed to better understand what value, if any, 3-option responses truly add to classroom assessments, and in what contexts potential benefits might be discernible.

  11. A physiologically based nonhomogeneous Poisson counter model of visual identification.

    PubMed

    Christensen, Jeppe H; Markussen, Bo; Bundesen, Claus; Kyllingsbæk, Søren

    2018-04-30

    A physiologically based nonhomogeneous Poisson counter model of visual identification is presented. The model was developed in the framework of a Theory of Visual Attention (Bundesen, 1990; Kyllingsbæk, Markussen, & Bundesen, 2012) and meant for modeling visual identification of objects that are mutually confusable and hard to see. The model assumes that the visual system's initial sensory response consists in tentative visual categorizations, which are accumulated by leaky integration of both transient and sustained components comparable with those found in spike density patterns of early sensory neurons. The sensory response (tentative categorizations) feeds independent Poisson counters, each of which accumulates tentative object categorizations of a particular type to guide overt identification performance. We tested the model's ability to predict the effect of stimulus duration on observed distributions of responses in a nonspeeded (pure accuracy) identification task with eight response alternatives. The time courses of correct and erroneous categorizations were well accounted for when the event-rates of competing Poisson counters were allowed to vary independently over time in a way that mimicked the dynamics of receptive field selectivity as found in neurophysiological studies. Furthermore, the initial sensory response yielded theoretical hazard rate functions that closely resembled empirically estimated ones. Finally, supplied with a Naka-Rushton type contrast gain control, the model provided an explanation for Bloch's law. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  12. Discrimination accuracy between real and sham press needles in the hands.

    PubMed

    Kim, Sungha; Lee, Sanghun; Choi, Sunmi; Park, Jeonghwan; Kim, Sungchul

    2015-08-01

    To evaluate the blinding effectiveness of a modified blunt sham press needle on the basis of the ability of subjects to discriminate between real and sham acupuncture needles compared with their discrimination ability based on pure guessing, and to define differences between senses (touch and vision) in the rates of correctly identified needles. Sixty-three healthy students and staff members were recruited through convenience sampling. First, real or sham acupuncture was randomly administered to the left LI4 point while subjects could not observe the needle tip. A real or sham needle tip was then shown to the subjects. Finally, a random combination of real or sham acupuncture needles were randomly administered to the left and right LI4 points, this time with the subjects observing the procedure. In all conditions the subjects gave their judgement as Yes or No in response to questions asking them to identify the needle type. The proportion of correct judgements (P(C)) was computed for the last part of the trial in left and right LI4 points, and the rates of correctly identified needles for each trial were obtained. The subjects' accuracy of discrimination between the real and sham acupuncture needles in left and right LI4 points was not significantly different from that based on pure guess (P(C)=0.50 (chance level)), which indicates complete inability to discriminate between needles. The rates of correctly identified needles using touch, vision and a combination of both senses were not significantly different (p=0.807). The findings from this study show that this sham acupuncture device successfully blinded subjects to real and sham press needles, suggesting that it is effective for subject blinding in studies on acupuncture using press needles, and facilitating evaluation of the effects of acupuncture in placebo-controlled trials using a rigorous scientific research methodology. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  13. Probability effects on stimulus evaluation and response processes

    NASA Technical Reports Server (NTRS)

    Gehring, W. J.; Gratton, G.; Coles, M. G.; Donchin, E.

    1992-01-01

    This study investigated the effects of probability information on response preparation and stimulus evaluation. Eight subjects responded with one hand to the target letter H and with the other to the target letter S. The target letter was surrounded by noise letters that were either the same as or different from the target letter. In 2 conditions, the targets were preceded by a warning stimulus unrelated to the target letter. In 2 other conditions, a warning letter predicted that the same letter or the opposite letter would appear as the imperative stimulus with .80 probability. Correct reaction times were faster and error rates were lower when imperative stimuli confirmed the predictions of the warning stimulus. Probability information affected (a) the preparation of motor responses during the foreperiod, (b) the development of expectancies for a particular target letter, and (c) a process sensitive to the identities of letter stimuli but not to their locations.

  14. Ionospheric E-Region Response to Solar-Geomagnetic Storms Observed by TIMED/SABER and Application to IRI Storm-Model Development

    NASA Technical Reports Server (NTRS)

    Mertens, Christopher J.; Mast, Jeffrey C.; Winick, Jeremy R.; Russell, James M., III; Mlynczak, Martin G.; Evans, David S.

    2007-01-01

    The large thermospheric infrared radiance enhancements observed from the TIMED/SABER experiment during recent solar storms provide an exciting opportunity to study the influence of solar-geomagnetic disturbances on the upper atmosphere and ionosphere. In particular, nighttime enhancements of 4.3 um emission, due to vibrational excitation and radiative emission by NO+, provide an excellent proxy to study and analyze the response of the ionospheric E-region to auroral electron dosing and storm-time enhancements to the E-region electron density. In this paper we give a status report of on-going work on model and data analysis methodologies of deriving NO+ 4.3 um volume emission rates, a proxy for the storm-time E-region response, and the approach for deriving an empirical storm-time correction to International Reference Ionosphere (IRI) E-region NO+ and electron densities.

  15. Why do they not answer and do they really learn? A case study in analysing student response flows in introductory physics using an audience response system

    NASA Astrophysics Data System (ADS)

    Jääskeläinen, Markku; Lagerkvist, Andreas

    2017-07-01

    In this paper we investigate teaching with a classroom response system in introductory physics with emphasis on two issues. First, we discuss retention between question rounds and the reasons why students avoid answering the question a second time. A question with declining response rate was followed by a question addressing the student reasons for not answering. We find that there appear to be several reasons for the observed decline, and that the students need to be reminded. We argue that small drops are unimportant as the process appears to work despite the drops. Second, we discuss the dynamics of learning in a concept-sequence in electromagnetism, where a majority of the students, despite poor statistics in a first round, manage to answer a followup question correctly. In addition, we analyse the response times for both situations to connect with research on student reasoning on situations with misconception-like answers. From the combination of the answer flows and response time behaviours we find it plausible that conceptual learning occurred during the discussion phase.

  16. Simultaneous acquisition of perfusion and permeability from corrected relaxation rates with dynamic susceptibility contrast dual gradient echo.

    PubMed

    Kim, Eun-Ju; Kim, Dae-Hong; Lee, Sang Hoon; Huh, Yong-Min; Song, Ho-Taek; Suh, Jin-Suck

    2004-04-01

    This study compared two methods, corrected (separation of T(1) and T(2)* effects) and uncorrected, in order to determine the suitability of the perfusion and permeability measures through Delta R(2)* and Delta R(1) analyses. A dynamic susceptibility contrast dual gradient echo (DSC-DGE) was used to image the fixed phantoms and flow phantoms (Sephadex perfusion phantoms and dialyzer phantom for the permeability measurements). The results confirmed that the corrected relaxation rate was linearly proportional to gadolinium-diethyltriamine pentaacetic acid (Gd-DTPA) concentration, whereas the uncorrected relaxation rate did not in the fixed phantom and simulation experiments. For the perfusion measurements, it was found that the correction process was necessary not only for the Delta R(1) time curve but also for the Delta R(2)* time curve analyses. Perfusion could not be measured without correcting the Delta R(2)* time curve. The water volume, which was expressed as the perfusion amount, was found to be closer to the theoretical value when using the corrected Delta R(1) curve in the calculations. However, this may occur in the low concentration of Gd-DTPA in tissue used in this study. For the permeability measurements based on the two-compartment model, the permeability factor (k(ev); e = extravascular, v = vascular) from the outside to the inside of the hollow fibers was greater in the corrected Delta R(1) method than in the uncorrected Delta R(1) method. The differences between the corrected and the uncorrected Delta R(1) values were confirmed by the simulation experiments. In conclusion, this study proposes that the correction for the relaxation rates, Delta R(2)* and Delta R(1), is indispensable in making accurate perfusion and permeability measurements, and that DSC-DGE is a useful method for obtaining information on perfusion and permeability, simultaneously.

  17. Professionals' and laypersons' appreciation of various options for Class III surgical correction.

    PubMed

    Fabré, M; Mossaz, C; Christou, P; Kiliaridis, S

    2010-08-01

    The objectives of this study were to evaluate the assessments of maxillofacial surgeons, orthodontists, and laypersons on the predicted aesthetic outcome of various surgical options in Class III correction and the associations between certain initial cephalometric values and the judges' preferred option. Pre-surgical lateral headfilms and coloured profile photographs of 18 skeletal Class III Caucasian adult patients (10 males and 8 females) with a mean age of 24.5 years were used. The headfilms were hand traced and digitized. Conventional cephalometric analysis was performed. Computerized predictions of three surgical options, mandibular setback, Le Fort I advancement, and bimaxillary surgery, were made. For each case, the pre-surgical profile photograph with the three predictions was presented on a printed page. The questionnaire was sent to 51 maxillofacial surgeons (response rate 45.1 per cent), 78 orthodontists (response rate 71.8 per cent), and 61 laypersons (response rate 100 per cent) to aesthetically evaluate the pre-surgical photographs and the surgical predictions by placing a mark along a 10-graded visual analogue scale (VAS) using a standard profile for calibration. Confidence interval was calculated for each patient. An independent samples t-test was used to detect initial cephalometric values associated with the judges' preferred option and analysis of variance/Tukey's honestly significant differences to evaluate differences between judges. Intra-observer reliability was assessed with a paired t-test. All treatment predictions led to improved scoring of facial aesthetics with the exception of the setback option for three patients. For 14 patients, general agreement for the preferred option existed between the three groups of judges. Laypersons tended to give lower improvement scores than professionals. Overjet, nasofacial, and nasomental angles were important in decision making between the mandibular setback and Le Fort I options (the more negative the overjet, the larger the nasofacial angle, the smaller the nasomental angle, the greater the preference for the Le Fort I option). Wits appraisal seemed to be important in decision making between the mandibular setback and bimaxillary options (the more negative the Wits appraisal, the greater the preference for the latter option).

  18. Selection of neural network structure for system error correction of electro-optical tracker system with horizontal gimbal

    NASA Astrophysics Data System (ADS)

    Liu, Xing-fa; Cen, Ming

    2007-12-01

    Neural Network system error correction method is more precise than lest square system error correction method and spheric harmonics function system error correction method. The accuracy of neural network system error correction method is mainly related to the frame of Neural Network. Analysis and simulation prove that both BP neural network system error correction method and RBF neural network system error correction method have high correction accuracy; it is better to use RBF Network system error correction method than BP Network system error correction method for little studying stylebook considering training rate and neural network scale.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dang, Liem X.; Vo, Quynh N.; Nilsson, Mikael

    We report one of the first simulations using a classical rate theory approach to predict the mechanism of the exchange process between water and aqueous uranyl ions. Using our water and ion-water polarizable force fields and molecular dynamics techniques, we computed the potentials of mean force for the uranyl ion-water pair as the function of pressures at ambient temperature. Subsequently, these simulated potentials of mean force were used to calculate rate constants using the transition rate theory; the time dependent transmission coefficients were also examined using the reactive flux method and Grote-Hynes treatments of the dynamic response of the solvent.more » The computed activation volumes using transition rate theory and the corrected rate constants are positive, thus the mechanism of this particular water-exchange is a dissociative process. We discuss our rate theory results and compare them with previously studies in which non-polarizable force fields were used. This work was supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences. The calculations were carried out using computer resources provided by the Office of Basic Energy Sciences.« less

  20. Spectral correction factors for conventional neutron dosemeters used in high-energy neutron environments.

    PubMed

    Lee, K W; Sheu, R J

    2015-04-01

    High-energy neutrons (>10 MeV) contribute substantially to the dose fraction but result in only a small or negligible response in most conventional moderated-type neutron detectors. Neutron dosemeters used for radiation protection purpose are commonly calibrated with (252)Cf neutron sources and are used in various workplace. A workplace-specific correction factor is suggested. In this study, the effect of the neutron spectrum on the accuracy of dose measurements was investigated. A set of neutron spectra representing various neutron environments was selected to study the dose responses of a series of Bonner spheres, including standard and extended-range spheres. By comparing (252)Cf-calibrated dose responses with reference values based on fluence-to-dose conversion coefficients, this paper presents recommendations for neutron field characterisation and appropriate correction factors for responses of conventional neutron dosemeters used in environments with high-energy neutrons. The correction depends on the estimated percentage of high-energy neutrons in the spectrum or the ratio between the measured responses of two Bonner spheres (the 4P6_8 extended-range sphere versus the 6″ standard sphere). © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Reconstructing ice-age palaeoclimates: Quantifying low-CO2 effects on plants

    NASA Astrophysics Data System (ADS)

    Prentice, I. C.; Cleator, S. F.; Huang, Y. H.; Harrison, S. P.; Roulstone, I.

    2017-02-01

    We present a novel method to quantify the ecophysiological effects of changes in CO2 concentration during the reconstruction of climate changes from fossil pollen assemblages. The method does not depend on any particular vegetation model. Instead, it makes use of general equations from ecophysiology and hydrology that link moisture index (MI) to transpiration and the ratio of leaf-internal to ambient CO2 (χ). Statistically reconstructed MI values are corrected post facto for effects of CO2 concentration. The correction is based on the principle that e, the rate of water loss per unit carbon gain, should be inversely related to effective moisture availability as sensed by plants. The method involves solving a non-linear equation that relates e to MI, temperature and CO2 concentration via the Fu-Zhang relation between evapotranspiration and MI, Monteith's empirical relationship between vapour pressure deficit and evapotranspiration, and recently developed theory that predicts the response of χ to vapour pressure deficit and temperature. The solution to this equation provides a correction term for MI. The numerical value of the correction depends on the reconstructed MI. It is slightly sensitive to temperature, but primarily sensitive to CO2 concentration. Under low LGM CO2 concentration the correction is always positive, implying that LGM climate was wetter than it would seem from vegetation composition. A statistical reconstruction of last glacial maximum (LGM, 21±1 kyr BP) palaeoclimates, based on a new compilation of modern and LGM pollen assemblage data from Australia, is used to illustrate the method in practice. Applying the correction brings pollen-reconstructed LGM moisture availability in southeastern Australia better into line with palaeohydrological estimates of LGM climate.

  2. Quantifying sources of bias in National Healthcare Safety Network laboratory-identified Clostridium difficile infection rates.

    PubMed

    Haley, Valerie B; DiRienzo, A Gregory; Lutterloh, Emily C; Stricof, Rachel L

    2014-01-01

    To assess the effect of multiple sources of bias on state- and hospital-specific National Healthcare Safety Network (NHSN) laboratory-identified Clostridium difficile infection (CDI) rates. Sensitivity analysis. A total of 124 New York hospitals in 2010. New York NHSN CDI events from audited hospitals were matched to New York hospital discharge billing records to obtain additional information on patient age, length of stay, and previous hospital discharges. "Corrected" hospital-onset (HO) CDI rates were calculated after (1) correcting inaccurate case reporting found during audits, (2) incorporating knowledge of laboratory results from outside hospitals, (3) excluding days when patients were not at risk from the denominator of the rates, and (4) adjusting for patient age. Data sets were simulated with each of these sources of bias reintroduced individually and combined. The simulated rates were compared with the corrected rates. Performance (ie, better, worse, or average compared with the state average) was categorized, and misclassification compared with the corrected data set was measured. Counting days patients were not at risk in the denominator reduced the state HO rate by 45% and resulted in 8% misclassification. Age adjustment and reporting errors also shifted rates (7% and 6% misclassification, respectively). Changing the NHSN protocol to require reporting of age-stratified patient-days and adjusting for patient-days at risk would improve comparability of rates across hospitals. Further research is needed to validate the risk-adjustment model before these data should be used as hospital performance measures.

  3. Analysis of binary responses with outcome-specific misclassification probability in genome-wide association studies.

    PubMed

    Rekaya, Romdhane; Smith, Shannon; Hay, El Hamidi; Farhat, Nourhene; Aggrey, Samuel E

    2016-01-01

    Errors in the binary status of some response traits are frequent in human, animal, and plant applications. These error rates tend to differ between cases and controls because diagnostic and screening tests have different sensitivity and specificity. This increases the inaccuracies of classifying individuals into correct groups, giving rise to both false-positive and false-negative cases. The analysis of these noisy binary responses due to misclassification will undoubtedly reduce the statistical power of genome-wide association studies (GWAS). A threshold model that accommodates varying diagnostic errors between cases and controls was investigated. A simulation study was carried out where several binary data sets (case-control) were generated with varying effects for the most influential single nucleotide polymorphisms (SNPs) and different diagnostic error rate for cases and controls. Each simulated data set consisted of 2000 individuals. Ignoring misclassification resulted in biased estimates of true influential SNP effects and inflated estimates for true noninfluential markers. A substantial reduction in bias and increase in accuracy ranging from 12% to 32% was observed when the misclassification procedure was invoked. In fact, the majority of influential SNPs that were not identified using the noisy data were captured using the proposed method. Additionally, truly misclassified binary records were identified with high probability using the proposed method. The superiority of the proposed method was maintained across different simulation parameters (misclassification rates and odds ratios) attesting to its robustness.

  4. Delays in using chromatic and luminance information to correct rapid reaches.

    PubMed

    Kane, Adam; Wade, Alex; Ma-Wyatt, Anna

    2011-09-07

    People can use feedback to make online corrections to movements but only if there is sufficient time to integrate the new information and make the correction. A key variable in this process is therefore the speed at which the new information about the target location is coded. Conduction velocities for chromatic signals are lower than for achromatic signals so it may take longer to correct reaches to chromatic stimuli. In addition to this delay, the sensorimotor system may prefer achromatic information over the chromatic information as delayed information may be less valuable when movements are made under time pressure. A down-weighting of chromatic information may result in additional latencies for chromatically directed reaches. In our study, participants made online corrections to reaches to achromatic, (L-M)-cone, and S-cone stimuli. Our chromatic stimuli were carefully adjusted to minimize stimulation of achromatic pathways, and we equated stimuli both in terms of detection thresholds and also by their estimated neural responses. Similar stimuli were used throughout the subjective adjustments and final reaching experiment. Using this paradigm, we found that responses to achromatic stimuli were only slightly faster than responses to (L-M)-cone and S-cone stimuli. We conclude that the sensorimotor system treats chromatic and achromatic information similarly and that the delayed chromatic responses primarily reflect early conduction delays.

  5. Vitamin D in addition to peg-interferon-alpha/ribavirin in chronic hepatitis C virus infection: ANRS-HC25-VITAVIC study.

    PubMed

    Terrier, Benjamin; Lapidus, Nathanael; Pol, Stanislas; Serfaty, Lawrence; Ratziu, Vlad; Asselah, Tarik; Thibault, Vincent; Souberbielle, Jean-Claude; Carrat, Fabrice; Cacoub, Patrice

    2015-05-14

    To investigate if correction of hypovitaminosis D before initiation of Peg-interferon-alpha/ribavirin (PegIFN/RBV) therapy could improve the efficacy of PegIFN/RBV in previously null-responder patients with chronic genotype 1 or 4 hepatitis C virus (HCV) infection. Genotype 1 or 4 HCV-infected patients with null response to previous PegIFN/RBV treatment and with hypovitaminosis D (< 30 ng/mL) prospectively received cholecalciferol 100000 IU per week for 4 wk [from week -4 (W-4) to W0], followed by 100000 IU per month in combination with PegIFN/RBV for 12 mo (from W0 to W48). The primary outcome was the rate of early virological response defined by an HCV RNA < 12 IU/mL after 12 wk PegIFN/RBV treatment. A total of 32 patients were included, 19 (59%) and 13 (41%) patients were HCV genotype 1 and 4, respectively. The median baseline vitamin D level was 15 ng/mL (range: 7-28). In modified intention-to-treat analysis, 29 patients who received at least one dose of PegIFN/RBV were included in the analysis. All patients except one normalized their vitamin D serum levels. The rate of early virologic response was 0/29 (0%). The rate of HCV RNA < 12 IU/mL after 24 wk of PegIFN/RBV was 1/27 (4%). The safety profile was favorable. Addition of vitamin D to PegIFN/RBV does not improve the rate of early virologic response in previously null-responders with chronic genotype 1 or 4 HCV infection.

  6. Application of the Exradin W1 scintillator to determine Ediode 60017 and microDiamond 60019 correction factors for relative dosimetry within small MV and FFF fields.

    PubMed

    Underwood, T S A; Rowland, B C; Ferrand, R; Vieillevigne, L

    2015-09-07

    In this work we use EBT3 film measurements at 10 MV to demonstrate the suitability of the Exradin W1 (plastic scintillator) for relative dosimetry within small photon fields. We then use the Exradin W1 to measure the small field correction factors required by two other detectors: the PTW unshielded Ediode 60017 and the PTW microDiamond 60019. We consider on-axis correction-factors for small fields collimated using MLCs for four different TrueBeam energies: 6 FFF, 6 MV, 10 FFF and 10 MV. We also investigate percentage depth dose and lateral profile perturbations. In addition to high-density effects from its silicon sensitive region, the Ediode exhibited a dose-rate dependence and its known over-response to low energy scatter was found to be greater for 6 FFF than 6 MV. For clinical centres without access to a W1 scintillator, we recommend the microDiamond over the Ediode and suggest that 'limits of usability', field sizes below which a detector introduces unacceptable errors, can form a practical alternative to small-field correction factors. For a dosimetric tolerance of 2% on-axis, the microDiamond might be utilised down to 10 mm and 15 mm field sizes for 6 MV and 10 MV, respectively.

  7. General practitioners' knowledge and concern about electromagnetic fields.

    PubMed

    Berg-Beckhoff, Gabriele; Breckenkamp, Jürgen; Larsen, Pia Veldt; Kowall, Bernd

    2014-12-01

    Our aim is to explore general practitioners' (GPs') knowledge about EMF, and to assess whether different knowledge structures are related to the GPs' concern about EMF. Random samples were drawn from lists of GPs in Germany in 2008. Knowledge about EMF was assessed by seven items. A latent class analysis was conducted to identify latent structures in GPs' knowledge. Further, the GPs' concern about EMF health risk was measured using a score comprising six items. The association between GPs' concern about EMF and their knowledge was analysed using multiple linear regression. In total 435 (response rate 23.3%) GPs participated in the study. Four groups were identified by the latent class analysis: 43.1% of the GPs gave mainly correct answers; 23.7% of the GPs answered low frequency EMF questions correctly; 19.2% answered only the questions relating EMF with health risks, and 14.0% answered mostly "don't know". There was no association between GPs' latent knowledge classes or between the number of correct answers given by the GPs and their EMF concern, whereas the number of incorrect answers was associated with EMF concern. Greater EMF concern in subjects with more incorrect answers suggests paying particular attention to misconceptions regarding EMF in risk communication.

  8. An epigenome-wide association analysis of cardiac autonomic responses among a population of welders.

    PubMed

    Zhang, Jinming; Liu, Zhonghua; Umukoro, Peter E; Cavallari, Jennifer M; Fang, Shona C; Weisskopf, Marc G; Lin, Xihong; Mittleman, Murray A; Christiani, David C

    2017-02-01

    DNA methylation is one of the potential epigenetic mechanisms associated with various adverse cardiovascular effects; however, its association with cardiac autonomic dysfunction, in particular, is unknown. In the current study, we aimed to identify epigenetic variants associated with alterations in cardiac autonomic responses. Cardiac autonomic responses were measured with two novel markers: acceleration capacity (AC) and deceleration capacity (DC). We examined DNA methylation levels at more than 472,506 CpG probes through the Illumina Infinium HumanMethylation450 BeadChip assay. We conducted separate linear mixed models to examine associations of DNA methylation levels at each CpG with AC and DC. One CpG (cg26829071) located in the GPR133 gene was negatively associated with DC values after multiple testing corrections through false discovery rate. Our study suggests the potential functional importance of methylation in cardiac autonomic responses. Findings from the current study need to be replicated in future studies in a larger population.

  9. Servo control booster system for minimizing following error

    DOEpatents

    Wise, W.L.

    1979-07-26

    A closed-loop feedback-controlled servo system is disclosed which reduces command-to-response error to the system's position feedback resolution least increment, ..delta..S/sub R/, on a continuous real-time basis, for all operational times of consequence and for all operating speeds. The servo system employs a second position feedback control loop on a by exception basis, when the command-to-response error greater than or equal to ..delta..S/sub R/, to produce precise position correction signals. When the command-to-response error is less than ..delta..S/sub R/, control automatically reverts to conventional control means as the second position feedback control loop is disconnected, becoming transparent to conventional servo control means. By operating the second unique position feedback control loop used herein at the appropriate clocking rate, command-to-response error may be reduced to the position feedback resolution least increment. The present system may be utilized in combination with a tachometer loop for increased stability.

  10. Stimulus-driven and knowledge-driven processes in attention to warbles

    NASA Astrophysics Data System (ADS)

    Dowling, W. Jay; Tillmann, Barbara

    2003-10-01

    Listeners identified warbles differing in amplitude-modulation rate (3-10 Hz). And measured RT while listeners maintained above 90% correct responses. After a practice session listeners identified target warbles following stimulus-driven or knowledge-driven cues. The stimulus-driven cue was a 250-ms ``beep'' at the target pitch (valid) or another pitch (invalid); the knowledge-driven cue was a midrange ``melody'' pointing to the target pitch (always valid). A 500-ms target warble followed the cue after delays of 0-500 ms (250-750 ms SOA). The listener pressed a key to indicate ``slow'' or ``fast.'' RTs were shortest at the briefest delay. In contrast to results from a memory task, RTs here were much shorter, and we found no evidence for IOR or attentional blink. Listeners began generating responses while the target was still sounding. Invalid ``beeps'' slowed responses at the briefest (but not the longer) delays; adding a valid ``beep'' to the valid ``melody'' did not speed responses.

  11. Biased but in Doubt: Conflict and Decision Confidence

    PubMed Central

    De Neys, Wim; Cromheeke, Sofie; Osman, Magda

    2011-01-01

    Human reasoning is often biased by intuitive heuristics. A central question is whether the bias results from a failure to detect that the intuitions conflict with traditional normative considerations or from a failure to discard the tempting intuitions. The present study addressed this unresolved debate by using people's decision confidence as a nonverbal index of conflict detection. Participants were asked to indicate how confident they were after solving classic base-rate (Experiment 1) and conjunction fallacy (Experiment 2) problems in which a cued intuitive response could be inconsistent or consistent with the traditional correct response. Results indicated that reasoners showed a clear confidence decrease when they gave an intuitive response that conflicted with the normative response. Contrary to popular belief, this establishes that people seem to acknowledge that their intuitive answers are not fully warranted. Experiment 3 established that younger reasoners did not yet show the confidence decrease, which points to the role of improved bias awareness in our reasoning development. Implications for the long standing debate on human rationality are discussed. PMID:21283574

  12. [Evaluation of an Experimental Production Wireless Dose Monitoring System for Radiation Exposure Management of Medical Staff].

    PubMed

    Fujibuchi, Toshioh; Murazaki, Hiroo; Kuramoto, Taku; Umedzu, Yoshiyuki; Ishigaki, Yung

    2015-08-01

    Because of the more advanced and more complex procedures in interventional radiology, longer treatment times have become necessary. Therefore, it is important to determine the exposure doses received by operators and patients. The aim of our study was to evaluate an experimental production wireless dose monitoring system for pulse radiation in diagnostic X-ray. The energy, dose rate, and pulse fluoroscopy dependence were evaluated as the basic characteristics of this system for diagnostic X-ray using a fully digital fluoroscopy system. The error of 1 cm dose equivalent rate was less than 15% from 35.1 keV to 43.2 keV with energy correction using metal filter. It was possible to accurately measure the dose rate dependence of this system, which was highly linear until 100 μSv/h. This system showed a constant response to the pulse fluoroscopy. This system will become useful wireless dosimeter for the individual exposure management by improving the high dose rate and the energy characteristics.

  13. A nonlinear lag correction algorithm for a-Si flat-panel x-ray detectors

    PubMed Central

    Starman, Jared; Star-Lack, Josh; Virshup, Gary; Shapiro, Edward; Fahrig, Rebecca

    2012-01-01

    Purpose: Detector lag, or residual signal, in a-Si flat-panel (FP) detectors can cause significant shading artifacts in cone-beam computed tomography reconstructions. To date, most correction models have assumed a linear, time-invariant (LTI) model and correct lag by deconvolution with an impulse response function (IRF). However, the lag correction is sensitive to both the exposure intensity and the technique used for determining the IRF. Even when the LTI correction that produces the minimum error is found, residual artifact remains. A new non-LTI method was developed to take into account the IRF measurement technique and exposure dependencies. Methods: First, a multiexponential (N = 4) LTI model was implemented for lag correction. Next, a non-LTI lag correction, known as the nonlinear consistent stored charge (NLCSC) method, was developed based on the LTI multiexponential method. It differs from other nonlinear lag correction algorithms in that it maintains a consistent estimate of the amount of charge stored in the FP and it does not require intimate knowledge of the semiconductor parameters specific to the FP. For the NLCSC method, all coefficients of the IRF are functions of exposure intensity. Another nonlinear lag correction method that only used an intensity weighting of the IRF was also compared. The correction algorithms were applied to step-response projection data and CT acquisitions of a large pelvic phantom and an acrylic head phantom. The authors collected rising and falling edge step-response data on a Varian 4030CB a-Si FP detector operating in dynamic gain mode at 15 fps at nine incident exposures (2.0%–92% of the detector saturation exposure). For projection data, 1st and 50th frame lag were measured before and after correction. For the CT reconstructions, five pairs of ROIs were defined and the maximum and mean signal differences within a pair were calculated for the different exposures and step-response edge techniques. Results: The LTI corrections left residual 1st and 50th frame lag up to 1.4% and 0.48%, while the NLCSC lag correction reduced 1st and 50th frame residual lags to less than 0.29% and 0.0052%. For CT reconstructions, the NLCSC lag correction gave an average error of 11 HU for the pelvic phantom and 3 HU for the head phantom, compared to 14–19 HU and 2–11 HU for the LTI corrections and 15 HU and 9 HU for the intensity weighted non-LTI algorithm. The maximum ROI error was always smallest for the NLCSC correction. The NLCSC correction was also superior to the intensity weighting algorithm. Conclusions: The NLCSC lag algorithm corrected for the exposure dependence of lag, provided superior image improvement for the pelvic phantom reconstruction, and gave similar results to the best case LTI results for the head phantom. The blurred ring artifact that is left over in the LTI corrections was better removed by the NLCSC correction in all cases. PMID:23039642

  14. Dose-response characteristics of an amorphous silicon EPID.

    PubMed

    Winkler, Peter; Hefner, Alfred; Georg, Dietmar

    2005-10-01

    Electronic portal imaging devices (EPIDs) were originally developed for the purpose of patient setup verification. Nowadays, they are increasingly used as dosimeters (e.g., for IMRT verification and linac-specific QA). A prerequisite for any clinical dosimetric application is a detailed understanding of the detector's dose-response behavior. The aim of this study is to investigate the dosimetric properties of an amorphous silicon EPID (Elekta IVIEWGT) with respect to three photon beam qualities: 6, 10, and 25 MV. The EPID showed an excellent temporal stability on short term as well as on long term scales. The stability throughout the day was strongly influenced by warming up, which took several hours and affected EPID response by 2.5%. Ghosting effects increased the sensitivity of the EPID. They became more pronounced with decreasing time intervals between two exposures as well as with increasing dose. Due to ghosting, changes in pixel sensitivity amounted up to 16% (locally) for the 25 MV photon beam. It was observed that the response characteristics of our EPID depended on dose as well as on dose rate. Doubling the dose rate increased the EPID sensitivity by 1.5%. This behavior was successfully attributed to a dose per frame effect, i.e., a nonlinear relationship between the EPID signal and the dose which was delivered to the panel between two successive readouts. The sensitivity was found to vary up to 10% in the range of 1 to 1000 monitor units. This variation was governed by two independent effects. For low doses, the EPID signal was reduced due to the linac's changing dose rate during startup. Furthermore, the detector reading was influenced by intrabeam variations of EPID sensitivity, namely, an increase of detector response during uniform exposure. For the beam qualities which were used, the response characteristics of the EPID did not depend on energy. Differences in relative dose-response curves resulted from energy dependent temporal output characteristics of the accelerator. If ghosting is prevented from affecting the results and all dose-response effects are properly corrected for, the EPID signal becomes independent of dose rate, dose, and exposure time.

  15. SU-F-J-219: Predicting Ventilation Change Due to Radiation Therapy: Dependency On Pre-RT Ventilation and Effort Correction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patton, T; Du, K; Bayouth, J

    Purpose: Ventilation change caused by radiation therapy (RT) can be predicted using four-dimensional computed tomography (4DCT) and image registration. This study tested the dependency of predicted post-RT ventilation on effort correction and pre-RT lung function. Methods: Pre-RT and 3 month post-RT 4DCT images were obtained for 13 patients. The 4DCT images were used to create ventilation maps using a deformable image registration based Jacobian expansion calculation. The post-RT ventilation maps were predicted in four different ways using the dose delivered, pre-RT ventilation, and effort correction. The pre-RT ventilation and effort correction were toggled to determine dependency. The four different predictedmore » ventilation maps were compared to the post-RT ventilation map calculated from image registration to establish the best prediction method. Gamma pass rates were used to compare the different maps with the criteria of 2mm distance-to-agreement and 6% ventilation difference. Paired t-tests of gamma pass rates were used to determine significant differences between the maps. Additional gamma pass rates were calculated using only voxels receiving over 20 Gy. Results: The predicted post-RT ventilation maps were in agreement with the actual post-RT maps in the following percentage of voxels averaged over all subjects: 71% with pre-RT ventilation and effort correction, 69% with no pre-RT ventilation and effort correction, 60% with pre-RT ventilation and no effort correction, and 58% with no pre-RT ventilation and no effort correction. When analyzing only voxels receiving over 20 Gy, the gamma pass rates were respectively 74%, 69%, 65%, and 55%. The prediction including both pre- RT ventilation and effort correction was the only prediction with significant improvement over using no prediction (p<0.02). Conclusion: Post-RT ventilation is best predicted using both pre-RT ventilation and effort correction. This is the only prediction that provided a significant improvement on agreement. Research support from NIH grants CA166119 and CA166703, a gift from Roger Koch, and a Pilot Grant from University of Iowa Carver College of Medicine.« less

  16. A prosocial online game for social cognition training in adolescents with high-functioning autism: an fMRI study.

    PubMed

    Chung, Un-Sun; Han, Doug Hyun; Shin, Yee Jin; Renshaw, Perry F

    2016-01-01

    To help patients with autism spectrum disorder (ASD) improve their social skills, effective interventions and new treatment modalities are necessary. We hypothesized that a prosocial online game would improve social cognition in ASD adolescents, as assessed using metrics of social communication, facial recognition, and emotional words. Ten ASD adolescents underwent cognitive behavior therapy (CBT) using a prosocial online game (game-CBT), and ten ASD adolescents participated in an offline-CBT. At baseline and 6 weeks later, social communication quality, correct identification of emotional words and facial emoticons, and brain activity were assessed in both groups. Social communication quality and correct response rate of emotional words and facial emoticons improved in both groups over the course of the intervention, and there were no significant differences between groups. In response to the emotional words, the brain activity within the temporal and parietal cortices increased in the game-CBT group, while the brain activity within cingulate and parietal cortices increased in the offline-CBT group. In addition, ASD adolescents in the game-CBT group showed increased brain activity within the right cingulate gyrus, left medial frontal gyrus, left cerebellum, left fusiform gyrus, left insular cortex, and sublobar area in response to facial emoticons. A prosocial online game designed for CBT was as effective as offline-CBT in ASD adolescents. Participation in the game especially increased social arousal and aided ASD adolescents in recognizing emotion. The therapy also helped participants more accurately consider associated environments in response to facial emotional stimulation. However, the online CBT was less effective than the offline-CBT at evoking emotions in response to emotional words.

  17. A prosocial online game for social cognition training in adolescents with high-functioning autism: an fMRI study

    PubMed Central

    Chung, Un-sun; Han, Doug Hyun; Shin, Yee Jin; Renshaw, Perry F

    2016-01-01

    To help patients with autism spectrum disorder (ASD) improve their social skills, effective interventions and new treatment modalities are necessary. We hypothesized that a prosocial online game would improve social cognition in ASD adolescents, as assessed using metrics of social communication, facial recognition, and emotional words. Ten ASD adolescents underwent cognitive behavior therapy (CBT) using a prosocial online game (game-CBT), and ten ASD adolescents participated in an offline-CBT. At baseline and 6 weeks later, social communication quality, correct identification of emotional words and facial emoticons, and brain activity were assessed in both groups. Social communication quality and correct response rate of emotional words and facial emoticons improved in both groups over the course of the intervention, and there were no significant differences between groups. In response to the emotional words, the brain activity within the temporal and parietal cortices increased in the game-CBT group, while the brain activity within cingulate and parietal cortices increased in the offline-CBT group. In addition, ASD adolescents in the game-CBT group showed increased brain activity within the right cingulate gyrus, left medial frontal gyrus, left cerebellum, left fusiform gyrus, left insular cortex, and sublobar area in response to facial emoticons. A prosocial online game designed for CBT was as effective as offline-CBT in ASD adolescents. Participation in the game especially increased social arousal and aided ASD adolescents in recognizing emotion. The therapy also helped participants more accurately consider associated environments in response to facial emotional stimulation. However, the online CBT was less effective than the offline-CBT at evoking emotions in response to emotional words. PMID:27051288

  18. 26 CFR 1.6050S-0 - Table of contents.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... penalties for failures to include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN. (4) Failure to furnish TIN. (f) Effective date. § 1.6050S-2TElectronic... include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN...

  19. 26 CFR 1.6050S-0 - Table of contents.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... penalties for failures to include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN. (4) Failure to furnish TIN. (f) Effective date. § 1.6050S-2TElectronic... include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN...

  20. 26 CFR 1.6050S-0 - Table of contents.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... penalties for failures to include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN. (4) Failure to furnish TIN. (f) Effective date. § 1.6050S-2TElectronic... include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN...

  1. 26 CFR 1.6050S-0 - Table of contents.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... penalties for failures to include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN. (4) Failure to furnish TIN. (f) Effective date. § 1.6050S-2TElectronic... include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN...

  2. 26 CFR 1.6050S-0 - Table of contents.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... penalties for failures to include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN. (4) Failure to furnish TIN. (f) Effective date. § 1.6050S-2TElectronic... include a correct TIN. (i) In general. (ii) Acting in a responsible manner. (iii) Manner of soliciting TIN...

  3. 78 FR 9902 - DOE Response to Recommendation 2012-2 of the Defense Nuclear Facilities Safety Board, Hanford...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-12

    ... DEPARTMENT OF ENERGY DOE Response to Recommendation 2012-2 of the Defense Nuclear Facilities Safety Board, Hanford Tank Farms Flammable Gas Safety Strategy; Correction AGENCY: Department of Energy... Facilities Safety Board, Hanford Tank Farms Flammable Gas Safety Strategy. This document corrects an error in...

  4. Piloting a Polychotomous Partial-Credit Scoring Procedure in a Multiple-Choice Test

    ERIC Educational Resources Information Center

    Tsopanoglou, Antonios; Ypsilandis, George S.; Mouti, Anna

    2014-01-01

    Multiple-choice (MC) tests are frequently used to measure language competence because they are quick, economical and straightforward to score. While degrees of correctness have been investigated for partially correct responses in combined-response MC tests, degrees of incorrectness in distractors and the role they play in determining the…

  5. Adaptive Criterion Setting in Perceptual Decision Making

    ERIC Educational Resources Information Center

    Stuttgen, Maik C.; Yildiz, Ali; Gunturkun, Onur

    2011-01-01

    Pigeons responded in a perceptual categorization task with six different stimuli (shades of gray), three of which were to be classified as "light" or "dark", respectively. Reinforcement probability for correct responses was varied from 0.2 to 0.6 across blocks of sessions and was unequal for correct light and dark responses. Introduction of a new…

  6. Better compliance and better tolerance in relation to a well-conducted introduction to rub-in hand disinfection.

    PubMed

    Girard, R; Amazian, K; Fabry, J

    2001-02-01

    The aim of the study was to demonstrate that the introduction of rub-in hand disinfection (RHD) in hospital units, with the implementation of suitable equipment, drafting of specific protocols, and training users, improved compliance of hand disinfection and tolerance of user's hands. In four hospital units not previously using RHD an external investigator conducted two identical studies in order to measure the rate of compliance with, and the quality of, disinfection practices, [rate of adapted (i.e., appropriate) procedures, rate of correct (i.e., properly performed) procedures, rate of adapted and correct procedures carried out] and to assess the state of hands (clinical scores of dryness and irritation, measuring hydration with a corneometer). Between the two studies, the units were equipped with dispensers for RHD products and staff were trained. Compliance improved from 62.2 to 66.5%, quality was improved (rate of adapted procedures from 66.8% to 84.3%, P > or = 10(-6), rate of correct procedures from 11.1% to 28.9%, P > or = 10(-8), rate of adapted and correct procedures from 6.0 to 17.8%, P > or = 10(-8)). The tolerance was improved significantly (P > or = 10(-2)) for clinical dryness and irritation scores, although not significantly for measurements using a corneometer. This study shows the benefit of introducing RHD with a technical and educational accompaniment. Copyright 2001 The Hospital Infection Society.

  7. Cooperative Learning as a Correction and Grammar Revision Technique: Communicative Exchanges, Self-Correction Rates and Scores

    ERIC Educational Resources Information Center

    Servetti, Sara

    2010-01-01

    This paper focuses on cooperative learning (CL) used as a correction and grammar revision technique and considers the data collected in six Italian parallel classes, three of which (sample classes) corrected mistakes and revised grammar through cooperative learning, while the other three (control classes) in a traditional way. All the classes…

  8. Stochastic theory of large-scale enzyme-reaction networks: Finite copy number corrections to rate equation models

    NASA Astrophysics Data System (ADS)

    Thomas, Philipp; Straube, Arthur V.; Grima, Ramon

    2010-11-01

    Chemical reactions inside cells occur in compartment volumes in the range of atto- to femtoliters. Physiological concentrations realized in such small volumes imply low copy numbers of interacting molecules with the consequence of considerable fluctuations in the concentrations. In contrast, rate equation models are based on the implicit assumption of infinitely large numbers of interacting molecules, or equivalently, that reactions occur in infinite volumes at constant macroscopic concentrations. In this article we compute the finite-volume corrections (or equivalently the finite copy number corrections) to the solutions of the rate equations for chemical reaction networks composed of arbitrarily large numbers of enzyme-catalyzed reactions which are confined inside a small subcellular compartment. This is achieved by applying a mesoscopic version of the quasisteady-state assumption to the exact Fokker-Planck equation associated with the Poisson representation of the chemical master equation. The procedure yields impressively simple and compact expressions for the finite-volume corrections. We prove that the predictions of the rate equations will always underestimate the actual steady-state substrate concentrations for an enzyme-reaction network confined in a small volume. In particular we show that the finite-volume corrections increase with decreasing subcellular volume, decreasing Michaelis-Menten constants, and increasing enzyme saturation. The magnitude of the corrections depends sensitively on the topology of the network. The predictions of the theory are shown to be in excellent agreement with stochastic simulations for two types of networks typically associated with protein methylation and metabolism.

  9. Impairment of Postural Control in Rabbits With Extensive Spinal Lesions

    PubMed Central

    Lyalka, V. F.; Orlovsky, G. N.; Deliagina, T. G.

    2009-01-01

    Our previous studies on rabbits demonstrated that the ventral spinal pathways are of primary importance for postural control in the hindquarters. After ventral hemisection, postural control did not recover, whereas after dorsal or lateral hemisection it did. The aim of this study was to examine postural capacity of rabbits after more extensive lesion (3/4 section of the spinal cord at T12 level), that is, with only one ventral quadrant spared (VQ animals). They were tested before (control) and after lesion on the platform periodically tilted in the frontal plane. In control animals, tilts of the platform regularly elicited coordinated electromyographic (EMG) responses in the hindlimbs, which resulted in generation of postural corrections and in maintenance of balance. In VQ rabbits, the EMG responses appeared only in a part of tilt cycles, and they could be either correctly or incorrectly phased in relation to tilts. Because of a reduced value and incorrect phasing of EMG responses on both sides, this muscle activity did not cause postural corrective movements in the majority of rabbits, and the body swayed together with the platform. In these rabbits, the ability to perform postural corrections did not recover during the whole period of observation (≤30 days). Low probability of correct EMG responses to tilts in most rabbits as well as an appearance of incorrect responses to tilts suggest that the spinal reflex chains, necessary for postural control, have not been specifically selected by a reduced supraspinal drive transmitted via a single ventral quadrant. PMID:19164112

  10. Central distractors in Force Concept Inventory data

    NASA Astrophysics Data System (ADS)

    Scott, Terry F.; Schumayer, Dániel

    2018-01-01

    The Force Concept Inventory was designed to poll the Newtonian conception of force. While there are many in-depth studies analyzing response data that look at the structure of the correct answers, we believe that the incorrect answers also carry revealing information about the students' worldview. The inventory was originally designed so that the "distractors" in each question reflected commonly held misconceptions, and thus the rate at which students guess the correct answer is very low. Students select incorrect answers that correspond to the misconception that they hold and there are very few responses which appear obviously wrong to students. A side effect of this approach is that the incorrect responses reflect the non-Newtonian worldviews held by students. These non-Newtonian worldviews are coherent and robust, and this, at least in part, helps to explain why these misconceptions are so resistant to instruction. In this study we focus once more on the misconception data in Force Concept Inventory responses, particularly on the linkages between these misconceptions. We hypothesize that there are distinct groupings of distractor items formed by the strength of the association between these items. The two largest groupings are associated with the "impetus" world view in which the motion of an object is determined by the quantity of impetus which that object contains. We find that certain central items hold particularly important places in these groupings and also that individual groupings may be connected to each other by "connector" items. We finally suggest that, on the basis of this study, that these non-Newtonian worldviews might best be dismantled by addressing these key central and connector items.

  11. Investigation of EBT2 and EBT3 films for proton dosimetry in the 4-20 MeV energy range.

    PubMed

    Reinhardt, S; Würl, M; Greubel, C; Humble, N; Wilkens, J J; Hillbrand, M; Mairani, A; Assmann, W; Parodi, K

    2015-03-01

    Radiochromic films such as Gafchromic EBT2 or EBT3 films are widely used for dose determination in radiation therapy because they offer a superior spatial resolution compared to any other digital dosimetric 2D detector array. The possibility to detect steep dose gradients is not only attractive for intensity-modulated radiation therapy with photons but also for intensity-modulated proton therapy. Their characteristic dose rate-independent response makes radiochromic films also attractive for dose determination in cell irradiation experiments using laser-driven ion accelerators, which are currently being investigated as future medical ion accelerators. However, when using these films in ion beams, the energy-dependent dose response in the vicinity of the Bragg peak has to be considered. In this work, the response of these films for low-energy protons is investigated. To allow for reproducible and background-free irradiation conditions, the films were exposed to mono-energetic protons from an electrostatic accelerator, in the 4-20 MeV energy range. For comparison, irradiation with clinical photons was also performed. It turned out that in general, EBT2 and EBT3 films show a comparable performance. For example, dose-response curves for photons and protons with energies as low as 11 MeV show almost no differences. However, corrections are required for proton energies below 11 MeV. Care has to be taken when correction factors are related to an average LET from depth-dose measurements, because only the dose-averaged LET yields similar results as obtained in mono-energetic measurements.

  12. Inhibitory control differentiates rare target search performance in children.

    PubMed

    Li, Hongting; Chan, John S Y; Cheung, Sui-Yin; Yan, Jin H

    2012-02-01

    Age-related differences in rare-target search are primarily explained by the speed-accuracy trade-off, primed responses, or decision making. The goal was to examine how motor inhibition influences visual search. Children pressed a key when a rare target was detected. On no-target trials, children withheld reactions. Response time (RT), hits, misses, correct rejection, and false alarms were measured. Tapping tests assessed motor control. Older children tapped faster, were more sensitive to rare targets (higher d'), and reacted more slowly than younger ones. Girls outperformed boys in search sensitivity but not in RT. Motor speed was closely associated with hit rate and RT. Results suggest that development of inhibitory control plays a key role in visual detection. The potential implications for cognitive-motor development and individual differences are discussed.

  13. Potential Energy Surface for Large Barrierless Reaction Systems: Application to the Kinetic Calculations of the Dissociation of Alkanes and the Reverse Recombination Reactions.

    PubMed

    Yao, Qian; Cao, Xiao-Mei; Zong, Wen-Gang; Sun, Xiao-Hui; Li, Ze-Rong; Li, Xiang-Yuan

    2018-05-31

    The isodesmic reaction method is applied to calculate the potential energy surface (PES) along the reaction coordinates and the rate constants of the barrierless reactions for unimolecular dissociation reactions of alkanes to form two alkyl radicals and their reverse recombination reactions. The reaction class is divided into 10 subclasses depending upon the type of carbon atoms in the reaction centers. A correction scheme based on isodesmic reaction theory is proposed to correct the PESs at UB3LYP/6-31+G(d,p) level. To validate the accuracy of this scheme, a comparison of the PESs at B3LYP level and the corrected PESs with the PESs at CASPT2/aug-cc-pVTZ level is performed for 13 representative reactions, and it is found that the deviations of the PESs at B3LYP level are up to 35.18 kcal/mol and are reduced to within 2 kcal/mol after correction, indicating that the PESs for barrierless reactions in a subclass can be calculated meaningfully accurately at a low level of ab initio method using our correction scheme. High-pressure limit rate constants and pressure dependent rate constants of these reactions are calculated based on their corrected PESs and the results show the pressure dependence of the rate constants cannot be ignored, especially at high temperatures. Furthermore, the impact of molecular size on the pressure-dependent rate constants of decomposition reactions of alkanes and their reverse reactions has been studied. The present work provides an effective method to generate meaningfully accurate PESs for large molecular system.

  14. Mass casualty incidents: are NHS staff prepared? An audit of one NHS foundation trust.

    PubMed

    Milkhu, C S; Howell, D C J; Glynne, P A; Raptis, D; Booth, H L; Langmead, L; Datta, V K

    2008-09-01

    Lack of knowledge of an NHS trust's major incident policies by clinical staff may result in poorly coordinated responses during a mass casualty incident (MCI). To audit knowledge of the major incident policy by clinical staff working in a central London major acute NHS trust designated to receive casualties on a 24-h basis during a MCI. A 12-question proforma was distributed to 307 nursing and medical staff in the hospital, designed to assess their knowledge of the major incident policy. Completed proformas were collected over a 2-month period between December 2006 and February 2007. A reply rate of 34% was obtained, with a reasonable representation from all disciplines ranging from nurses to consultants. Despite only 41% having read the policy in full, 70% knew the correct immediate action to take if informed of major incident activation. 76% knew the correct stand-down procedure. 56% knew the correct reporting point but less than 25% knew that an action card system was utilised. Nurses had significantly (p<0.01) more awareness of the policy than doctors. In view of the heightened terrorist threat in London, knowledge of major incident policy is essential. The high percentage of positive responses relating to immediate and stand-down actions reflects the rolling trust-wide MCI education programme and the organisational memory of the trust following several previous MCI in the capital. There is still scope for an improvement in awareness, however, particularly concerning knowledge of action cards, which are now displayed routinely throughout clinical areas and will be incorporated into induction packs.

  15. The Accuracy and Precision of Flow Measurements Using Phase Contrast Techniques

    NASA Astrophysics Data System (ADS)

    Tang, Chao

    Quantitative volume flow rate measurements using the magnetic resonance imaging technique are studied in this dissertation because the volume flow rates have a special interest in the blood supply of the human body. The method of quantitative volume flow rate measurements is based on the phase contrast technique, which assumes a linear relationship between the phase and flow velocity of spins. By measuring the phase shift of nuclear spins and integrating velocity across the lumen of the vessel, we can determine the volume flow rate. The accuracy and precision of volume flow rate measurements obtained using the phase contrast technique are studied by computer simulations and experiments. The various factors studied include (1) the partial volume effect due to voxel dimensions and slice thickness relative to the vessel dimensions; (2) vessel angulation relative to the imaging plane; (3) intravoxel phase dispersion; (4) flow velocity relative to the magnitude of the flow encoding gradient. The partial volume effect is demonstrated to be the major obstacle to obtaining accurate flow measurements for both laminar and plug flow. Laminar flow can be measured more accurately than plug flow in the same condition. Both the experiment and simulation results for laminar flow show that, to obtain the accuracy of volume flow rate measurements to within 10%, at least 16 voxels are needed to cover the vessel lumen. The accuracy of flow measurements depends strongly on the relative intensity of signal from stationary tissues. A correction method is proposed to compensate for the partial volume effect. The correction method is based on a small phase shift approximation. After the correction, the errors due to the partial volume effect are compensated, allowing more accurate results to be obtained. An automatic program based on the correction method is developed and implemented on a Sun workstation. The correction method is applied to the simulation and experiment results. The results show that the correction significantly reduces the errors due to the partial volume effect. We apply the correction method to the data of in vivo studies. Because the blood flow is not known, the results of correction are tested according to the common knowledge (such as cardiac output) and conservation of flow. For example, the volume of blood flowing to the brain should be equal to the volume of blood flowing from the brain. Our measurement results are very convincing.

  16. Re-evaluation of the correction factors for the GROVEX

    NASA Astrophysics Data System (ADS)

    Ketelhut, Steffen; Meier, Markus

    2018-04-01

    The GROVEX (GROssVolumige EXtrapolationskammer, large-volume extrapolation chamber) is the primary standard for the dosimetry of low-dose-rate interstitial brachytherapy at the Physikalisch-Technische Bundesanstalt (PTB). In the course of setup modifications and re-measuring of several dimensions, the correction factors have been re-evaluated in this work. The correction factors for scatter and attenuation have been recalculated using the Monte Carlo software package EGSnrc, and a new expression has been found for the divergence correction. The obtained results decrease the measured reference air kerma rate by approximately 0.9% for the representative example of a seed of type Bebig I25.S16C. This lies within the expanded uncertainty (k  =  2).

  17. Being right is its own reward: load and performance related ventral striatum activation to correct responses during a working memory task in youth.

    PubMed

    Satterthwaite, Theodore D; Ruparel, Kosha; Loughead, James; Elliott, Mark A; Gerraty, Raphael T; Calkins, Monica E; Hakonarson, Hakon; Gur, Ruben C; Gur, Raquel E; Wolf, Daniel H

    2012-07-02

    The ventral striatum (VS) is a critical brain region for reinforcement learning and motivation. Intrinsically motivated subjects performing challenging cognitive tasks engage reinforcement circuitry including VS even in the absence of external feedback or incentives. However, little is known about how such VS responses develop with age, relate to task performance, and are influenced by task difficulty. Here we used fMRI to examine VS activation to correct and incorrect responses during a standard n-back working memory task in a large sample (n=304) of healthy children, adolescents and young adults aged 8-22. We found that bilateral VS activates more strongly to correct than incorrect responses, and that the VS response scales with the difficulty of the working memory task. Furthermore, VS response was correlated with discrimination performance during the task, and the magnitude of VS response peaked in mid-adolescence. These findings provide evidence for scalable intrinsic reinforcement signals during standard cognitive tasks, and suggest a novel link between motivation and cognition during adolescent development. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Cochlear Microphonic and Summating Potential Responses from Click-Evoked Auditory Brain Stem Responses in High-Risk and Normal Infants.

    PubMed

    Hunter, Lisa L; Blankenship, Chelsea M; Gunter, Rebekah G; Keefe, Douglas H; Feeney, M Patrick; Brown, David K; Baroch, Kelly

    2018-05-01

    Examination of cochlear and neural potentials is necessary to assess sensory and neural status in infants, especially those cared for in neonatal intensive care units (NICU) who have high rates of hyperbilirubinemia and thus are at risk for auditory neuropathy (AN). The purpose of this study was to determine whether recording parameters commonly used in click-evoked auditory brain stem response (ABR) are useful for recording cochlear microphonic (CM) and Wave I in infants at risk for AN. Specifically, we analyzed CM, summating potential (SP), and Waves I, III, and V. The overall aim was to compare latencies and amplitudes of evoked responses in infants cared for in NICUs with infants in a well-baby nursery (WBN), both of which passed newborn hearing screening. This is a prospective study in which infants who passed ABR newborn hearing screening were grouped based on their birth history (WBN and NICU). All infants had normal hearing status when tested with diagnostic ABR at about one month of age, corrected for prematurity. Thirty infants (53 ears) from the WBN [mean corrected age at test = 5.0 weeks (wks.)] and thirty-two infants (59 ears) from the NICU (mean corrected age at test = 5.7 wks.) with normal hearing were included in this study. In addition, two infants were included as comparative case studies, one that was diagnosed with AN and another case that was diagnosed with bilateral sensorineural hearing loss (SNHL). Diagnostic ABR, including click and tone-burst air- and bone-conduction stimuli were recorded. Peak Waves I, III, and V; SP; and CM latency and amplitude (peak to trough) were measured to determine if there were differences in ABR and electrocochleography (ECochG) variables between WBN and NICU infants. No significant group differences were found between WBN and NICU groups for ABR waveforms, CM, or SP, including amplitude and latency values. The majority (75%) of the NICU group had hyperbilirubinemia, but overall, they did not show evidence of effects in their ECochG or ABR responses when tested at about one-month corrected age. These data may serve as a normative sample for NICU and well infant ECochG and ABR latencies at one-month corrected age. Two infant case studies, one diagnosed with AN and another with SNHL demonstrated the complexity of using ECochG and otoacoustic emissions to assess the risk of AN in individual cases. CM and SPs can be readily measured using standard click stimuli in both well and NICU infants. Normative ranges for latency and amplitude are useful for interpreting ECochG and ABR components. Inclusion of ECochG and ABR tests in a test battery that also includes otoacoustic emission and acoustic reflex tests may provide a more refined assessment of the risks of AN and SNHL in infants. American Academy of Audiology.

  19. Disordered Gambling Prevalence: Methodological Innovations in a General Danish Population Survey.

    PubMed

    Harrison, Glenn W; Jessen, Lasse J; Lau, Morten I; Ross, Don

    2018-03-01

    We study Danish adult gambling behavior with an emphasis on discovering patterns relevant to public health forecasting and economic welfare assessment of policy. Methodological innovations include measurement of formative in addition to reflective constructs, estimation of prospective risk for developing gambling disorder rather than risk of being falsely negatively diagnosed, analysis with attention to sample weights and correction for sample selection bias, estimation of the impact of trigger questions on prevalence estimates and sample characteristics, and distinguishing between total and marginal effects of risk-indicating factors. The most significant novelty in our design is that nobody was excluded on the basis of their response to a 'trigger' or 'gateway' question about previous gambling history. Our sample consists of 8405 adult Danes. We administered the Focal Adult Gambling Screen to all subjects and estimate prospective risk for disordered gambling. We find that 87.6% of the population is indicated for no detectable risk, 5.4% is indicated for early risk, 1.7% is indicated for intermediate risk, 2.6% is indicated for advanced risk, and 2.6% is indicated for disordered gambling. Correcting for sample weights and controlling for sample selection has a significant effect on prevalence rates. Although these estimates of the 'at risk' fraction of the population are significantly higher than conventionally reported, we infer a significant decrease in overall prevalence rates of detectable risk with these corrections, since gambling behavior is positively correlated with the decision to participate in gambling surveys. We also find that imposing a threshold gambling history leads to underestimation of the prevalence of gambling problems.

  20. 77 FR 57990 - Interest Rate Risk Policy and Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    ... NATIONAL CREDIT UNION ADMINISTRATION 12 CFR Part 741 RIN 3133-AD66 Interest Rate Risk Policy and Program Correction In rule document 2012-02091, appearing on pages 55155-5167 in the issue of Thursday, February 2, 2012, make the following corrections: 1. On page 5157, in the second column, in the first line...

  1. Corrected High-Frame Rate Anchored Ultrasound with Software Alignment

    ERIC Educational Resources Information Center

    Miller, Amanda L.; Finch, Kenneth B.

    2011-01-01

    Purpose: To improve lingual ultrasound imaging with the Corrected High Frame Rate Anchored Ultrasound with Software Alignment (CHAUSA; Miller, 2008) method. Method: A production study of the IsiXhosa alveolar click is presented. Articulatory-to-acoustic alignment is demonstrated using a Tri-Modal 3-ms pulse generator. Images from 2 simultaneous…

  2. Partial-Interval Estimation of Count: Uncorrected and Poisson-Corrected Error Levels

    ERIC Educational Resources Information Center

    Yoder, Paul J.; Ledford, Jennifer R.; Harbison, Amy L.; Tapp, Jon T.

    2018-01-01

    A simulation study that used 3,000 computer-generated event streams with known behavior rates, interval durations, and session durations was conducted to test whether the main and interaction effects of true rate and interval duration affect the error level of uncorrected and Poisson-transformed (i.e., "corrected") count as estimated by…

  3. Ear molding in newborn infants with auricular deformities.

    PubMed

    Byrd, H Steve; Langevin, Claude-Jean; Ghidoni, Lorraine A

    2010-10-01

    A review of a single physician's experience in managing over 831 infant ear deformities (488 patients) is presented. The authors' methods of molding have advanced from the use of various tapes, glues, and stents, to a comprehensive yet simple system that shapes the antihelix, the triangular fossa, the helical rim, and the overly prominent conchal-mastoid angle (EarWell Infant Ear Correction System). The types of deformities managed, and their relative occurrence, are as follows: (1) prominent/cup ear, 373 ears (45 percent); (2) lidding/lop ear, 224 ears (27 percent); (3) mixed ear deformities, 83 ears (10 percent) (all had associated conchal crus); (4) Stahl's ear, 66 ears (8 percent); (5) helical rim abnormalities, 58 ears (7 percent); (6) conchal crus, 25 ears (3 percent); and (7) cryptotia, two ears (0.2 percent). Bilateral deformities were present in 340 patients (70 percent), with unilateral deformities in 148 patients (30 percent). Fifty-eight infant ears (34 patients) were treated using the final version of the EarWell Infant Ear Correction System with a success rate exceeding 90 percent (good to excellent results). The system was found to be most successful when begun in the first week of the infant's life. When molding was initiated after 3 weeks from birth, only approximately half of the infants had a good response. Congenital ear deformities are common and only approximately 30 percent self-correct. These deformities can be corrected by initiating appropriate molding in the first week of life. Neonatal molding reduces the need for surgical correction with results that often exceed what can be achieved with the surgical alternative.

  4. International survey of knowledge of food-induced anaphylaxis

    PubMed Central

    Wang, Julie; Young, Michael C.; Nowak-Węgrzyn, Anna

    2014-01-01

    Background Studies show that anaphylaxis is under-recognized and epinephrine (adrenaline) is under-used by medical personnel as well as patients and their families. This study assesses the knowledge of food-induced anaphylaxis diagnosis and management across different populations of providers and caregivers and other interested respondents. Methods An online survey embedded in a case discussion food-induced anaphylaxis was distributed by Medscape to registered members. Results 7822 responders who started the activity chose to answer at least some of the questions presented (response rate 39.5%). Over 80% of responders in all groups correctly identified the case of anaphylaxis with prominent skin and respiratory symptoms, however, only 55% correctly recognized the case without skin symptoms as anaphylaxis. Only 23% of responders correctly selected risk factors for anaphylaxis, with physicians significantly more likely to choose the correct answers as compared to allied health, other health professionals and medical students (p<0.001). Ninety five perecnt selected epinephrine (adrenaline) as the most appropriate treatment for anaphylaxis, and 81% correctly indicated that there are no absolute contraindications for epinephrine (adrenaline) in the setting of anaphylaxis. When presented a case of a child with no documented history of allergies who has symptoms of anaphylaxis, more physicians than any other group chose to administer stock epinephrine (adrenaline) (73% vs 60%, p<0.001). Conclusion Specific knowledge deficits for food-induced anaphylaxis persist across all groups. Further educational efforts should be aimed not only at the medical community but also for the entire caregiver community and general public, to optimize care for food allergic individuals. PMID:25263184

  5. Counting-loss correction for X-ray spectroscopy using unit impulse pulse shaping.

    PubMed

    Hong, Xu; Zhou, Jianbin; Ni, Shijun; Ma, Yingjie; Yao, Jianfeng; Zhou, Wei; Liu, Yi; Wang, Min

    2018-03-01

    High-precision measurement of X-ray spectra is affected by the statistical fluctuation of the X-ray beam under low-counting-rate conditions. It is also limited by counting loss resulting from the dead-time of the system and pile-up pulse effects, especially in a high-counting-rate environment. In this paper a detection system based on a FAST-SDD detector and a new kind of unit impulse pulse-shaping method is presented, for counting-loss correction in X-ray spectroscopy. The unit impulse pulse-shaping method is evolved by inverse deviation of the pulse from a reset-type preamplifier and a C-R shaper. It is applied to obtain the true incoming rate of the system based on a general fast-slow channel processing model. The pulses in the fast channel are shaped to unit impulse pulse shape which possesses small width and no undershoot. The counting rate in the fast channel is corrected by evaluating the dead-time of the fast channel before it is used to correct the counting loss in the slow channel.

  6. Improving Hybrid III injury assessment in steering wheel rim to chest impacts using responses from finite element Hybrid III and human body model.

    PubMed

    Holmqvist, Kristian; Davidsson, Johan; Mendoza-Vazquez, Manuel; Rundberget, Peter; Svensson, Mats Y; Thorn, Stefan; Törnvall, Fredrik

    2014-01-01

    The main aim of this study was to improve the quality of injury risk assessments in steering wheel rim to chest impacts when using the Hybrid III crash test dummy in frontal heavy goods vehicle (HGV) collision tests. Correction factors for chest injury criteria were calculated as the model chest injury parameter ratios between finite element (FE) Hybrid III, evaluated in relevant load cases, and the Total Human Model for Safety (THUMS). This is proposed to be used to compensate Hybrid III measurements in crash tests where steering wheel rim to chest impacts occur. The study was conducted in an FE environment using an FE-Hybrid III model and the THUMS. Two impactor shapes were used, a circular hub and a long, thin horizontal bar. Chest impacts at velocities ranging from 3.0 to 6.0 m/s were simulated at 3 impact height levels. A ratio between FE-Hybrid III and THUMS chest injury parameters, maximum chest compression C max, and maximum viscous criterion VC max, were calculated for the different chest impact conditions to form a set of correction factors. The definition of the correction factor is based on the assumption that the response from a circular hub impact to the middle of the chest is well characterized and that injury risk measures are independent of impact height. The current limits for these chest injury criteria were used as a basis to develop correction factors that compensate for the limitations in biofidelity of the Hybrid III in steering wheel rim to chest impacts. The hub and bar impactors produced considerably higher C max and VC max responses in the THUMS compared to the FE-Hybrid III. The correction factor for the responses of the FE-Hybrid III showed that the criteria responses for the bar impactor were consistently overestimated. Ratios based on Hybrid III and THUMS responses provided correction factors for the Hybrid III responses ranging from 0.84 to 0.93. These factors can be used to estimate C max and VC max values when the Hybrid III is used in crash tests for which steering wheel rim to chest interaction occurs. For the FE-Hybrid III, bar impacts caused higher chest deflection compared to hub impacts, although the contrary results were obtained with the more humanlike THUMS. Correction factors were developed that can be used to correct the Hybrid III chest responses. Higher injury criteria capping limits for steering wheel impacts are acceptable. Supplemental materials are available for this article. Go to the publisher's online edition of Traffic Injury Prevention to view the supplemental file.

  7. Development of a drift-correction procedure for a direct-reading spectrometer

    NASA Technical Reports Server (NTRS)

    Chapman, G. B., II; Gordon, W. A.

    1977-01-01

    A procedure which provides automatic correction for drifts in the radiometric sensitivity of each detector channel in a direct-reading emission spectrometer is described. Such drifts are customarily controlled by the regular analyses of standards, which provide corrections for changes in the excitational, optical, and electronic components of the instrument. This standardization procedure, however, corrects for the optical and electronic drifts. It is a step that must be taken if the time, effort, and cost of processing standards is to be minimized. This method of radiometric drift correction uses a 1,000-W tungsten-halogen reference lamp to illuminate each detector through the same optical path as that traversed during sample analysis. The responses of the detector channels to this reference light are regularly compared with channel response to the same light intensity at the time of analytical calibration in order to determine and correct for drift. Except for placing the lamp in position, the procedure is fully automated and compensates for changes in spectral intensity due to variations in lamp current. A discussion of the implementation of this drift-correction system is included.

  8. Frequency Response of Pressure Sensitive Paints

    NASA Technical Reports Server (NTRS)

    Winslow, Neal A.; Carroll, Bruce F.; Setzer, Fred M.

    1996-01-01

    An experimental method for measuring the frequency response of Pressure Sensitive Paints (PSP) is presented. These results lead to the development of a dynamic correction technique for PSP measurements which is of great importance to the advancement of PSP as a measurement technique. The ability to design such a dynamic corrector is most easily formed from the frequency response of the given system. An example of this correction technique is shown. In addition to the experimental data, an analytical model for the frequency response is developed from the one dimensional mass diffusion equation.

  9. Hard decoding algorithm for optimizing thresholds under general Markovian noise

    NASA Astrophysics Data System (ADS)

    Chamberland, Christopher; Wallman, Joel; Beale, Stefanie; Laflamme, Raymond

    2017-04-01

    Quantum error correction is instrumental in protecting quantum systems from noise in quantum computing and communication settings. Pauli channels can be efficiently simulated and threshold values for Pauli error rates under a variety of error-correcting codes have been obtained. However, realistic quantum systems can undergo noise processes that differ significantly from Pauli noise. In this paper, we present an efficient hard decoding algorithm for optimizing thresholds and lowering failure rates of an error-correcting code under general completely positive and trace-preserving (i.e., Markovian) noise. We use our hard decoding algorithm to study the performance of several error-correcting codes under various non-Pauli noise models by computing threshold values and failure rates for these codes. We compare the performance of our hard decoding algorithm to decoders optimized for depolarizing noise and show improvements in thresholds and reductions in failure rates by several orders of magnitude. Our hard decoding algorithm can also be adapted to take advantage of a code's non-Pauli transversal gates to further suppress noise. For example, we show that using the transversal gates of the 5-qubit code allows arbitrary rotations around certain axes to be perfectly corrected. Furthermore, we show that Pauli twirling can increase or decrease the threshold depending upon the code properties. Lastly, we show that even if the physical noise model differs slightly from the hypothesized noise model used to determine an optimized decoder, failure rates can still be reduced by applying our hard decoding algorithm.

  10. Adult perceptions of dental fluorosis and select dental conditions-an Asian perspective.

    PubMed

    Nair, Rahul; Chuang, Janice Cheah Ping; Lee, Pauline Shih Jia; Leo, Song Jie; Yang, Naomi QiYue; Yee, Robert; Tong, Huei Jinn

    2016-04-01

    To compare lay people's perceptions with regard to various levels of dental fluorosis and select dental defects versus normal dentition. Adults rated digitally created photographs made showing lips (without retraction) and teeth depicting the following conditions: no apparent aesthetic defects (normal, Thylstrup- Fejerskov score 0 - TF0), 6 levels of fluorosis (TF1-6), carious lesions (two cavitated and one noncavitated), malocclusions (Class II, Class III, anterior open bite and greater spacing), extrinsic staining and an incisal chip. The photographs were displayed on colour-calibrated iPads(™) . Participants used a self-administered questionnaire to rate their perceptions on (Item 1) how normal teeth were, (Item 2) how attractive the teeth were, (Item 3) need to seek correction of teeth, (Item 4) how well the person took care of their teeth and (Item 5) whether the person was born like this. Data from Item 5 were excluded due to low reliability. Ratings for Item 1 showed that TF1-4 was similar or significantly better than TF0. For Item 2, TF1 and TF4 were significantly better than TF0, with TF2 and TF3 being similar. For Item 3, there was significantly lower need to seek correction with TF2 and TF4 versus TF0, whereas TF1 and TF3 were similar to TF0. TF5 and TF6 were rated significantly lower than TF0 for Item 1 and Item 2, and significantly higher rating for Item 3 (need to seek correction). Ratings for Item 4 were similar, with TF1, TF2 and TF4 being rated significantly higher than TF0, and TF5 and TF6 being rated lower. Cavitated caries and staining were generally perceived as being significantly less favourable than TF6, with higher need to seek correction as well. Noncavitated carious lesion and incisal chip were rated similar to TF0. Cavitated carious lesions were rated aesthetically similar or significantly worse than TF0 and TF6. Severe fluorosis (TF5 and 6) was perceived to be less aesthetically pleasing and received higher ratings for need to seek correction than normal teeth. Mild-to-moderate fluorosis (TF1-4) showed similar or better aesthetic perceptions and similar or lower need to seek correction, when compared to normal teeth (TF0). Easily visible cavitated dental caries was rated worse than teeth with severe fluorosis (TF6) and normal teeth (TF0). © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Fine figure correction and other applications using novel MRF fluid designed for ultra-low roughness

    NASA Astrophysics Data System (ADS)

    Maloney, Chris; Oswald, Eric S.; Dumas, Paul

    2015-10-01

    An increasing number of technologies require ultra-low roughness (ULR) surfaces. Magnetorheological Finishing (MRF) is one of the options for meeting the roughness specifications for high-energy laser, EUV and X-ray applications. A novel MRF fluid, called C30, has been developed to finish surfaces to ULR. This novel MRF fluid is able to achieve <1.5Å RMS roughness on fused silica and other materials, but has a lower material removal rate with respect to other MRF fluids. As a result of these properties, C30 can also be used for applications in addition to finishing ULR surfaces. These applications include fine figure correction, figure correcting extremely soft materials and removing cosmetic defects. The effectiveness of these new applications is explored through experimental data. The low removal rate of C30 gives MRF the capability to fine figure correct low amplitude errors that are usually difficult to correct with higher removal rate fluids. The ability to figure correct extremely soft materials opens up MRF to a new realm of materials that are difficult to polish. C30 also offers the ability to remove cosmetic defects that often lead to failure during visual quality inspections. These new applications for C30 expand the niche in which MRF is typically used for.

  12. Machine Learned Replacement of N-Labels for Basecalled Sequences in DNA Barcoding.

    PubMed

    Ma, Eddie Y T; Ratnasingham, Sujeevan; Kremer, Stefan C

    2018-01-01

    This study presents a machine learning method that increases the number of identified bases in Sanger Sequencing. The system post-processes a KB basecalled chromatogram. It selects a recoverable subset of N-labels in the KB-called chromatogram to replace with basecalls (A,C,G,T). An N-label correction is defined given an additional read of the same sequence, and a human finished sequence. Corrections are added to the dataset when an alignment determines the additional read and human agree on the identity of the N-label. KB must also rate the replacement with quality value of in the additional read. Corrections are only available during system training. Developing the system, nearly 850,000 N-labels are obtained from Barcode of Life Datasystems, the premier database of genetic markers called DNA Barcodes. Increasing the number of correct bases improves reference sequence reliability, increases sequence identification accuracy, and assures analysis correctness. Keeping with barcoding standards, our system maintains an error rate of percent. Our system only applies corrections when it estimates low rate of error. Tested on this data, our automation selects and recovers: 79 percent of N-labels from COI (animal barcode); 80 percent from matK and rbcL (plant barcodes); and 58 percent from non-protein-coding sequences (across eukaryotes).

  13. Modulation of thermal pain-related brain activity with virtual reality: evidence from fMRI.

    PubMed

    Hoffman, Hunter G; Richards, Todd L; Coda, Barbara; Bills, Aric R; Blough, David; Richards, Anne L; Sharar, Sam R

    2004-06-07

    This study investigated the neural correlates of virtual reality analgesia. Virtual reality significantly reduced subjective pain ratings (i.e. analgesia). Using fMRI, pain-related brain activity was measured for each participant during conditions of no virtual reality and during virtual reality (order randomized). As predicted, virtual reality significantly reduced pain-related brain activity in all five regions of interest; the anterior cingulate cortex, primary and secondary somatosensory cortex, insula, and thalamus (p<0.002, corrected). Results showed direct modulation of human brain pain responses by virtual reality distraction. Copyright 2004 Lippincott Williams and Wilkins

  14. Explosive response model evaluation using the explosive H6

    NASA Astrophysics Data System (ADS)

    Sutherland, Gerrit T.; Burns, Joseph

    2000-04-01

    Reactive rate model parameters for a two term Lee Tarver [simplified ignition and growth (SIG)] model were obtained for the explosive H6 from modified gap test data. These model was used to perform simulations of the underwater sensitivity test (UST) using the CTH hydrocode. Reaction was predicted in the simulations for the same water gaps that reaction was observed in the UST. The expansions observed for the UST samples were not simulated correctly, and this is attributed to the density equilibrium conditions imposed between unreacted and reacted components in CTH for the Lee-Tarver model.

  15. The ISEE-3 ULEWAT: Flux tape description and heavy ion fluxes 1978-1984. [plasma diagnostics

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Klecker, B.

    1985-01-01

    The ISEE ULEWAT FLUX tapes contain ULEWAT and ISEE pool tape data summarized over relatively long time intervals (1hr) in order to compact the data set into an easily usable size. (Roughly 3 years of data fit onto one 1600 BPI 9-track magnetic tape). In making the tapes, corrections were made to the ULEWAT basic data tapes in order to, remove rate spikes and account for changes in instrument response so that to a large extent instrument fluxes can be calculated easily from the FLUX tapes without further consideration of instrument performance.

  16. Predicting the extent of metabolism using in vitro permeability rate measurements and in silico permeability rate predictions

    PubMed Central

    Hosey, Chelsea M; Benet, Leslie Z

    2015-01-01

    The Biopharmaceutics Drug Disposition Classification System (BDDCS) can be utilized to predict drug disposition, including interactions with other drugs and transporter or metabolizing enzyme effects based on the extent of metabolism and solubility of a drug. However, defining the extent of metabolism relies upon clinical data. Drugs exhibiting high passive intestinal permeability rates are extensively metabolized. Therefore, we aimed to determine if in vitro measures of permeability rate or in silico permeability rate predictions could predict the extent of metabolism, to determine a reference compound representing the permeability rate above which compounds would be expected to be extensively metabolized, and to predict the major route of elimination of compounds in a two-tier approach utilizing permeability rate and a previously published model predicting the major route of elimination of parent drug. Twenty-two in vitro permeability rate measurement data sets in Caco-2 and MDCK cell lines and PAMPA were collected from the literature, while in silico permeability rate predictions were calculated using ADMET Predictor™ or VolSurf+. The potential for permeability rate to differentiate between extensively and poorly metabolized compounds was analyzed with receiver operating characteristic curves. Compounds that yielded the highest sensitivity-specificity average were selected as permeability rate reference standards. The major route of elimination of poorly permeable drugs was predicted by our previously published model and the accuracies and predictive values were calculated. The areas under the receiver operating curves were >0.90 for in vitro measures of permeability rate and >0.80 for the VolSurf+ model of permeability rate, indicating they were able to predict the extent of metabolism of compounds. Labetalol and zidovudine predicted greater than 80% of extensively metabolized drugs correctly and greater than 80% of poorly metabolized drugs correctly in Caco-2 and MDCK, respectively, while theophylline predicted greater than 80% of extensively and poorly metabolized drugs correctly in PAMPA. A two-tier approach predicting elimination route predicts 72±9%, 49±10%, and 66±7% of extensively metabolized, biliarily eliminated, and renally eliminated parent drugs correctly when the permeability rate is predicted in silico and 74±7%, 85±2%, and 73±8% of extensively metabolized, biliarily eliminated, and renally eliminated parent drugs correctly, respectively when the permeability rate is determined in vitro. PMID:25816851

  17. Observational intensity bias associated with illness adjustment: cross sectional analysis of insurance claims

    PubMed Central

    Staiger, Douglas O; Sharp, Sandra M; Gottlieb, Daniel J; Bevan, Gwyn; McPherson, Klim; Welch, H Gilbert

    2013-01-01

    Objective To determine the bias associated with frequency of visits by physicians in adjusting for illness, using diagnoses recorded in administrative databases. Setting Claims data from the US Medicare program for services provided in 2007 among 306 US hospital referral regions. Design Cross sectional analysis. Participants 20% sample of fee for service Medicare beneficiaries residing in the United States in 2007 (n=5 153 877). Main outcome measures The effect of illness adjustment on regional mortality and spending rates using standard and visit corrected illness methods for adjustment. The standard method adjusts using comorbidity measures based on diagnoses listed in administrative databases; the modified method corrects these measures for the frequency of visits by physicians. Three conventions for measuring comorbidity are used: the Charlson comorbidity index, Iezzoni chronic conditions, and hierarchical condition categories risk scores. Results The visit corrected Charlson comorbidity index explained more of the variation in age, sex, and race mortality across the 306 hospital referral regions than did the standard index (R2=0.21 v 0.11, P<0.001) and, compared with sex and race adjusted mortality, reduced regional variation, whereas adjustment using the standard Charlson comorbidity index increased it. Although visit corrected and age, sex, and race adjusted mortality rates were similar in hospital referral regions with the highest and lowest fifths of visits, adjustment using the standard index resulted in a rate that was 18% lower in the highest fifth (46.4 v 56.3 deaths per 1000, P<0.001). Age, sex, and race adjusted spending as well as visit corrected spending was more than 30% greater in the highest fifth of visits than in the lowest fifth, but only 12% greater after adjustment using the standard index. Similar results were obtained using the Iezzoni and the hierarchical condition categories conventions for measuring comorbidity. Conclusion The rates of visits by physicians introduce substantial bias when regional mortality and spending rates are adjusted for illness using comorbidity measures based on the observed number of diagnoses recorded in Medicare’s administrative database. Adjusting without correction for regional variation in visit rates tends to make regions with high rates of visits seem to have lower mortality and lower costs, and vice versa. Visit corrected comorbidity measures better explain variation in age, sex, and race mortality than observed measures, and reduce observational intensity bias. PMID:23430282

  18. Inserting Mastered Targets during Error Correction When Teaching Skills to Children with Autism

    ERIC Educational Resources Information Center

    Plaisance, Lauren; Lerman, Dorothea C.; Laudont, Courtney; Wu, Wai-Ling

    2016-01-01

    Research has identified a variety of effective approaches for responding to errors during discrete-trial training. In one commonly used method, the therapist delivers a prompt contingent on the occurrence of an incorrect response and then re-presents the trial so that the learner has an opportunity to perform the correct response independently.…

  19. Initial Experiences with Machine-Assisted Reconsiderative Test Scoring: A New Method for Partial Credit and Multiple Correct Responses.

    ERIC Educational Resources Information Center

    Anderson, Paul S.

    Initial experiences with computer-assisted reconsiderative scoring are described. Reconsiderative scoring occurs when student responses are received and reviewed by the teacher before points for correctness are assigned. Manually scored completion-style questions are reconsiderative. A new method of machine assistance produces an item analysis on…

  20. Conditions Fostering the Use of Informative Feedback by Young Children.

    ERIC Educational Resources Information Center

    Teager, Joyce; Stern, Carolyn

    In order to investigate the effect of reinforcement on learning, 21 disadvantaged black children, 4 to 5 years of age, were divided among three treatment groups. Group I children received only feedback (information) as to the correctness or incorrectness of their responses. Group II children received a raisin for each correct response, and group…

Top