Clinical predictors of the optimal spectacle correction for comfort performing desktop tasks.
Leffler, Christopher T; Davenport, Byrd; Rentz, Jodi; Miller, Amy; Benson, William
2008-11-01
The best strategy for spectacle correction of presbyopia for near tasks has not been determined. Thirty volunteers over the age of 40 years were tested for subjective accommodative amplitude, pupillary size, fusional vergence, interpupillary distance, arm length, preferred working distance, near and far visual acuity and preferred reading correction in the phoropter and trial frames. Subjects performed near tasks (reading, writing and counting change) using various spectacle correction strengths. Predictors of the correction maximising near task comfort were determined by multivariable linear regression. The mean age was 54.9 years (range 43 to 71) and 40 per cent had diabetes. Significant predictors of the most comfortable addition in univariate analyses were age (p<0.001), interpupillary distance (p=0.02), fusional vergence amplitude (p=0.02), distance visual acuity in the worse eye (p=0.01), vision at 40 cm in the worse eye with distance correction (p=0.01), duration of diabetes (p=0.01), and the preferred correction to read at 40 cm with the phoropter (p=0.002) or trial frames (p<0.001). Target distance selected wearing trial frames (in dioptres), arm length, and accommodative amplitude were not significant predictors (p>0.15). The preferred addition wearing trial frames holding a reading target at a distance selected by the patient was the only independent predictor. Excluding this variable, distance visual acuity was predictive independent of age or near vision wearing distance correction. The distance selected for task performance was predicted by vision wearing distance correction at near and at distance. Multivariable linear regression can be used to generate tables based on distance visual acuity and age or near vision wearing distance correction to determine tentative near spectacle addition. Final spectacle correction for desktop tasks can be estimated by subjective refraction with trial frames.
Code of Federal Regulations, 2010 CFR
2010-07-01
... distance and near vision using Snellen's test type or its equivalent. (b) Evaluation of visual acuity. (1) Evaluate central visual acuity on the basis of corrected distance vision with central fixation, even if a central scotoma is present. However, when the lens required to correct distance vision in the poorer eye...
Code of Federal Regulations, 2011 CFR
2011-07-01
... distance and near vision using Snellen's test type or its equivalent. (b) Evaluation of visual acuity. (1) Evaluate central visual acuity on the basis of corrected distance vision with central fixation, even if a central scotoma is present. However, when the lens required to correct distance vision in the poorer eye...
Venter, Jan A; Oberholster, Andre; Schallhorn, Steven C; Pelouskova, Martina
2014-04-01
To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to correct residual refractive error were analyzed. All eyes previously had in-the-bag zonal refractive multifocal intraocular lens implantation (Lentis Mplus MF30, models LS-312 and LS-313; Oculentis GmbH, Berlin, Germany) and required residual refractive error correction. Outcome measurements included uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, distance-corrected near visual acuity, manifest refraction, and complications. One-year data are presented in this study. The mean spherical equivalent ranged from -1.75 to +3.25 diopters (D) preoperatively (mean: +0.58 ± 1.15 D) and reduced to -1.25 to +0.50 D (mean: -0.14 ± 0.28 D; P < .01). Postoperatively, 93.8% of eyes were within ±0.50 D and 98.8% were within ±1.00 D of emmetropia. The mean uncorrected distance visual acuity improved significantly from 0.28 ± 0.16 to 0.01 ± 0.10 logMAR and 78.8% of eyes achieved 6/6 (Snellen 20/20) or better postoperatively. The mean uncorrected near visual acuity changed from 0.43 ± 0.28 to 0.19 ± 0.15 logMAR. There was no significant change in corrected distance visual acuity or distance-corrected near visual acuity. No serious intraoperative or postoperative complications requiring secondary intraocular lens removal occurred. Sulcoflex lenses proved to be a predictable and safe option for correcting residual refractive error in patients diagnosed as having pseudophakia. Copyright 2014, SLACK Incorporated.
Kemper, Alex R.; Gurney, James G.; Eibschitz-Tsimhoni, Maya; DelMonte, Monte A.
2007-01-01
Purpose To evaluate demographic variations in the use of corrective lenses among adolescent children. Methods Cross-sectional analysis of 3,916 children 12-18 years who participated in the 1999-2002 National Health and Nutrition Examination Survey (NHANES) vision examination component, which included: questions regarding use of corrective lenses; distance visual acuity, with corrective lenses if available; and non-cycloplegic autorefraction. Results reflect population-level estimates. Results Overall, 32.2% (95% confidence interval [CI]: 29.5%-35.0%) reported wearing corrective lenses. Girls and those with any private insurance had greater adjusted odds of reporting wearing corrective lenses. In contrast, children aged 15 through 18 years versus those 12 through 14 years, and white children compared to Black or Hispanic children had greater adjusted odds of actually having them available at the time of NHANES participation. Although 12.6% (95% CI: 8.8%-16.3%) of those who did not have their previously prescribed corrective lenses available had 20/25 or better distance visual acuity in both eyes without correction, 26.9% (95% CI:21.6%-32.1%) with their corrective lenses had distance visual acuity of 20/40 or worse in at least one eye when using their corrective lenses. Limitations Near visual acuity was not measured and children with corrective lenses available only had their corrected distance visual acuity measured. No data regarding the accuracy of the NHANES assessment of distance visual acuity are available. Autorefraction was performed without cycloplegia. Conclusions Many adolescent children report wearing corrective lenses. Variations across demographic characteristics appear to be due to a combination of undertreatment, overtreatment, and compliance with previously recommended corrective lenses. PMID:18062494
Impact of Target Distance, Target Size, and Visual Acuity on the Video Head Impulse Test.
Judge, Paul D; Rodriguez, Amanda I; Barin, Kamran; Janky, Kristen L
2018-05-01
The video head impulse test (vHIT) assesses the vestibulo-ocular reflex. Few have evaluated whether environmental factors or visual acuity influence the vHIT. The purpose of this study was to evaluate the influence of target distance, target size, and visual acuity on vHIT outcomes. Thirty-eight normal controls and 8 subjects with vestibular loss (VL) participated. vHIT was completed at 3 distances and with 3 target sizes. Normal controls were subdivided on the basis of visual acuity. Corrective saccade frequency, corrective saccade amplitude, and gain were tabulated. In the normal control group, there were no significant effects of target size or visual acuity for any vHIT outcome parameters; however, gain increased as target distance decreased. The VL group demonstrated higher corrective saccade frequency and amplitude and lower gain as compared with controls. In conclusion, decreasing target distance increases gain for normal controls but not subjects with VL. Preliminarily, visual acuity does not affect vHIT outcomes.
Khoramnia, Rahmin; Attia, Mary Safwat; Koss, Michael Janusz; Linz, Katharina; Auffarth, Gerd Uwe
2016-01-01
Purpose To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Methods Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. Results The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. Conclusions The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance. PMID:27729759
Kretz, Florian Tobias Alwin; Khoramnia, Rahmin; Attia, Mary Safwat; Koss, Michael Janusz; Linz, Katharina; Auffarth, Gerd Uwe
2016-10-01
To evaluate postoperative outcomes and visual performance in intermediate distance after implantation of a +1.5 diopters (D) addition, aspheric, rotational asymmetric multifocal intraocular lens (MIOL). Patients underwent bilateral cataract surgery with implantation of an aspheric, asymmetric MIOL with +1.5 D near addition. A complete ophthalmological examination was performed preoperatively and 3 months postoperatively. The main outcome measures were monocular and binocular uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA) and distance corrected keratometry, and manifest refraction. The Salzburg Reading Desk was used to analyze unilateral and bilateral functional vision with uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at near and intermediate distances. The study comprised 60 eyes of 30 patients (mean age, 68.30 ± 9.26 years; range, 34 to 80 years). There was significant improvement in UDVA and CDVA. Mean UIVA was 0.01 ± 0.09 logarithm of the minimum angle of resolution (logMAR) and mean DCIVA was -0.02 ± 0.11 logMAR. In Salzburg Reading Desk analysis for UIVA, the mean subjective intermediate distance was 67.58 ± 8.59 cm with mean UIVA of -0.02 ± 0.09 logMAR and mean word count of 96.38 ± 28.32 words/min. The new aspheric, asymmetric, +1.5 D near addition MIOL offers good results for distance visual function in combination with good performance for intermediate distances and functional results for near distance.
Differences in children and adolescents' ability of reporting two CVS-related visual problems.
Hu, Liang; Yan, Zheng; Ye, Tiantian; Lu, Fan; Xu, Peng; Chen, Hao
2013-01-01
The present study examined whether children and adolescents can correctly report dry eyes and blurred distance vision, two visual problems associated with computer vision syndrome. Participants are 913 children and adolescents aged 6-17. They were asked to report their visual problems, including dry eyes and blurred distance vision, and received an eye examination, including tear film break-up time (TFBUT) and visual acuity (VA). Inconsistency was found between participants' reports of dry eyes and TFBUT results among all 913 participants as well as for all of four subgroups. In contrast, consistency was found between participants' reports of blurred distance vision and VA results among 873 participants who had never worn glasses as well as for the four subgroups. It was concluded that children and adolescents are unable to report dry eyes correctly; however, they are able to report blurred distance vision correctly. Three practical implications of the findings were discussed. Little is known about children's ability to report their visual problems, an issue critical to diagnosis and treatment of children's computer vision syndrome. This study compared children's self-reports and clinic examination results and found children can correctly report blurred distance vision but not dry eyes.
Effect of astigmatism on visual acuity in eyes with a diffractive multifocal intraocular lens.
Hayashi, Ken; Manabe, Shin-Ichi; Yoshida, Motoaki; Hayashi, Hideyuki
2010-08-01
To examine the effect of astigmatism on visual acuity at various distances in eyes with a diffractive multifocal intraocular lens (IOL). Hayashi Eye Hospital, Fukuoka, Japan. In this study, eyes had implantation of a diffractive multifocal IOL with a +3.00 diopter (D) addition (add) (AcrySof ReSTOR SN6AD1), a diffractive multifocal IOL with a +4.00 D add (AcrySof ReSTOR SN6AD3), or a monofocal IOL (AcrySof SN60WF). Astigmatism was simulated by adding cylindrical lenses of various diopters (0.00, 0.50, 1.00, 1.50, 2.00), after which distance-corrected acuity was measured at various distances. At most distances, the mean visual acuity in the multifocal IOL groups decreased in proportion to the added astigmatism. With astigmatism of 0.00 D and 0.50 D, distance-corrected near visual acuity (DCNVA) in the +4.00 D group and distance-corrected intermediate visual acuity (DCIVA) and DCNVA in the +3.00 D group were significantly better than in the monofocal group; the corrected distance visual acuity (CDVA) was similar. The DCNVA with astigmatism of 1.00 D was better in 2 multifocal groups; however, with astigmatism of 1.50 D and 2.00 D, the CDVA and DCIVA at 0.5m in the multifocal groups were significantly worse than in the monofocal group, although the DCNVA was similar. With astigmatism of 1.00 D or greater, the mean CDVA and DCNVA in the multifocal groups reached useful levels (20/40). The presence of astigmatism in eyes with a diffractive multifocal IOL compromised all distance visual acuities, suggesting the need to correct astigmatism of greater than 1.00 D. No author has a financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Kretz, Florian T A; Gerl, Matthias; Gerl, Ralf; Müller, Matthias; Auffarth, Gerd U
2015-12-01
To evaluate the clinical outcomes after cataract surgery with implantation of a new diffractive multifocal intraocular lens (IOL) with a lower near addition (+2.75 D.). 143 eyes of 85 patients aged between 40 years and 83 years that underwent cataract surgery with implantation of the multifocal IOL (MIOL) Tecnis ZKB00 (Abbott Medical Optics,Santa Ana, California, USA) were evaluated. Changes in uncorrected (uncorrected distance visual acuity, uncorrected intermediate visual acuity, uncorrected near visual acuity) and corrected (corrected distance visual acuity, corrected near visual acuity) logMAR distance, intermediate visual acuity and near visual acuity, as well as manifest refraction were evaluated during a 3-month follow-up. Additionally, patients were asked about photic phenomena and spectacle dependence. Postoperative spherical equivalent was within ±0.50 D and ±1.00 D of emmetropia in 78.1% and 98.4% of eyes, respectively. Postoperative mean monocular uncorrected distance visual acuity, uncorrected near visual acuity and uncorrected intermediate visual acuity was 0.20 LogMAR or better in 73.7%, 81.1% and 83.9% of eyes, respectively. All eyes achieved monocular corrected distance visual acuity of 0.30 LogMAR or better. A total of 100% of patients referred to be at least moderately happy with the outcomes of the surgery. Only 15.3% of patients required the use of spectacles for some daily activities postoperatively. The introduction of low add MIOLs follows a trend to increase intermediate visual acuity. In this study a near add of +2.75 D still reaches satisfying near results and leads to high patient satisfaction for intermediate visual acuity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Chung, Byunghoon; Lee, Hun; Choi, Bong Joon; Seo, Kyung Ryul; Kim, Eung Kwon; Kim, Dae Yune; Kim, Tae-Im
2017-02-01
The purpose of this study was to investigate the clinical efficacy of an optimized prolate ablation procedure for correcting residual refractive errors following laser surgery. We analyzed 24 eyes of 15 patients who underwent an optimized prolate ablation procedure for the correction of residual refractive errors following laser in situ keratomileusis, laser-assisted subepithelial keratectomy, or photorefractive keratectomy surgeries. Preoperative ophthalmic examinations were performed, and uncorrected distance visual acuity, corrected distance visual acuity, manifest refraction values (sphere, cylinder, and spherical equivalent), point spread function, modulation transfer function, corneal asphericity (Q value), ocular aberrations, and corneal haze measurements were obtained postoperatively at 1, 3, and 6 months. Uncorrected distance visual acuity improved and refractive errors decreased significantly at 1, 3, and 6 months postoperatively. Total coma aberration increased at 3 and 6 months postoperatively, while changes in all other aberrations were not statistically significant. Similarly, no significant changes in point spread function were detected, but modulation transfer function increased significantly at the postoperative time points measured. The optimized prolate ablation procedure was effective in terms of improving visual acuity and objective visual performance for the correction of persistent refractive errors following laser surgery.
Hayashi, Ken; Yoshida, Motoaki; Manabe, Shin-ichi; Hayashi, Hideyuki
2010-01-01
To compare all-distance visual acuity and contrast visual acuity with and without glare (glare visual acuity) between phakic eyes with a clear lens and pseudophakic eyes with a monofocal intraocular lens. Hayashi Eye Hospital, Fukuoka, Japan. This study comprised phakic), pseudophakic eyes in 4 age groups (40s, 50s, 60s, 70s). Corrected visual acuity from far to near, contrast visual acuity, and glare visual acuity were examined. The mean corrected intermediate and near visual acuities were significantly better in phakic eyes than in pseudophakic eyes in patients in their 40s and 50s (P
Zheleznyak, Len; Alarcon, Aixa; Dieter, Kevin C.; Tadin, Duje; Yoon, Geunyoung
2015-01-01
Monovision presbyopia interventions exploit the binocular nature of the visual system by independently manipulating the optical properties of the two eyes. It is unclear, however, how individual variations in ocular dominance affect visual function in monovision corrections. Here, we examined the impact of sensory ocular dominance on visual performance in both traditional and modified monovision presbyopic corrections. We recently developed a binocular adaptive optics vision simulator to correct subjects' native aberrations and induce either modified monovision (1.5 D anisometropia, spherical aberration of +0.1 and −0.4 μm in distance and near eyes, respectively, over 4 mm pupils) or traditional monovision (1.5 D anisometropia). To quantify both the sign and the degree of ocular dominance, we utilized binocular rivalry to estimate stimulus contrast ratios that yield balanced dominance durations for the two eyes. Through-focus visual acuity and contrast sensitivity were measured under two conditions: (a) assigning dominant and nondominant eye to distance and near, respectively, and (b) vice versa. The results revealed that through-focus visual acuity was unaffected by ocular dominance. Contrast sensitivity, however, was significantly improved when the dominant eye coincided with superior optical quality. We hypothesize that a potential mechanism behind this observation is an interaction between ocular dominance and binocular contrast summation, and thus, assignment of the dominant eye to distance or near may be an important factor to optimize contrast threshold performance at different object distances in both modified and traditional monovision. PMID:26024464
Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses
Unsal, Ugur; Baser, Gonen
2016-01-01
Purpose. To compare near, intermediate, and distance vision and quality of vision, when refractive rotational multifocal intraocular lenses with 3.0 diopters or diffractive multifocal intraocular lenses with 2.5 diopters near addition are implanted. Methods. 41 eyes of 41 patients in whom rotational +3.0 diopters near addition IOLs were implanted and 30 eyes of 30 patients in whom diffractive +2.5 diopters near addition IOLs were implanted after cataract surgery were reviewed. Uncorrected and corrected distance visual acuity, intermediate visual acuity, near visual acuity, and patient satisfaction were evaluated 6 months later. Results. The corrected and uncorrected distance visual acuity were the same between both groups (p = 0.50 and p = 0.509, resp.). The uncorrected intermediate and corrected intermediate and near vision acuities were better in the +2.5 near vision added intraocular lens implanted group (p = 0.049, p = 0.005, and p = 0.001, resp.) and the uncorrected near vision acuity was better in the +3.0 near vision added intraocular lens implanted group (p = 0.001). The patient satisfactions of both groups were similar. Conclusion. The +2.5 diopters near addition could be a better choice in younger patients with more distance and intermediate visual requirements (driving, outdoor activities), whereas the + 3.0 diopters should be considered for patients with more near vision correction (reading). PMID:27340560
Alio, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José; Moreno, Luis J; Piñero, David P
2012-03-01
To compare the visual acuity outcomes and ocular optical performance of eyes implanted with a multifocal refractive intraocular lens (IOL) with an inferior segmental near add or a diffractive multifocal IOL. Prospective, comparative, nonrandomized, consecutive case series. Eighty-three consecutive eyes of 45 patients (age range, 36-82 years) with cataract were divided into 2 groups: group A, 45 eyes implanted with Lentis Mplus LS-312 (Oculentis GmbH, Berlin, Germany); group B, 38 eyes implanted with diffractive IOL Acri.Lisa 366D (Zeiss, Oberkochen, Germany). All patients underwent phacoemulsification followed by IOL implantation in the capsular bag. Distance corrected, intermediate, and near with the distance correction visual acuity outcomes and contrast sensitivity, intraocular aberrations, and defocus curve were evaluated postoperatively during a 3-month follow-up. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), corrected distance near and intermediate visual acuity (CDNVA), contrast sensitivity, intraocular aberrations, and defocus curve. A significant improvement in UDVA, CDVA, and UNVA was observed in both groups after surgery (P ≤ 0.04). Significantly better values of UNVA (P<0.01) and CDNVA (P<0.04) were found in group B. In the defocus curve, significantly better visual acuities were present in eyes in group A for intermediate vision levels of defocus (P ≤ 0.04). Significantly higher amounts of postoperative intraocular primary coma and spherical aberrations were found in group A (P<0.01). In addition, significantly better values were observed in photopic contrast sensitivity for high spatial frequencies in group A (P ≤ 0.04). The Lentis Mplus LS-312 and Acri.Lisa 366D IOLs are able to successfully restore visual function after cataract surgery. The Lentis Mplus LS-312 provided better intermediate vision and contrast sensitivity outcomes than the Acri.Lisa 366D. However, the Acri.Lisa design provided better distance and near visual outcomes and intraocular optical performance parameters. Copyright © 2012 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Visual performance after the implantation of a new trifocal intraocular lens
Vryghem, Jérôme C; Heireman, Steven
2013-01-01
Purpose To evaluate the subjective and objective visual results after the implantation of a new trifocal diffractive intraocular lens. Methods A new trifocal diffractive intraocular lens was designed combining two superimposed diffractive profiles: one with +1.75 diopters (D) addition for intermediate vision and the other with +3.50 D addition for near vision. Fifty eyes of 25 patients that were operated on by one surgeon are included in this study. The uncorrected and best distance-corrected monocular and binocular, near, intermediate, and distance visual acuities, contrast sensitivity, and defocus curves were measured 6 months postoperatively. In addition to the standard clinical follow-up, a questionnaire evaluating individual satisfaction and quality of life was submitted to the patients. Results The mean age of patients at the time of surgery was 70 ± 10 years. The mean uncorrected and corrected monocular distance visual acuity (VA) were LogMAR 0.06 ± 0.10 and LogMAR 0.00 ± 0.08, respectively. The outcomes for the binocular uncorrected distance visual acuity were almost the same (LogMAR −0.04 ± 0.09). LogMAR −010 ± 0.15 and 0.02 ± 0.06 were measured for the binocular uncorrected intermediate and near VA, respectively. The distance-corrected visual acuity was maintained in mesopic conditions. The contrast sensitivity was similar to that obtained after implantation of a bifocal intraocular lens and did not decrease in mesopic conditions. The binocular defocus curve confirms good VA even in the intermediate distance range, with a moderate decrease of less than LogMAR 0.2 at −1.5 D, with respect to the best distance VA at 0 D defocus. Patient satisfaction was high. No discrepancy between the objective and subjective outcomes was evidenced. Conclusion The introduction of a third focus in diffractive multifocal intraocular lenses improves the intermediate vision with minimal visual discomfort for the patient. PMID:24124348
Psychophysical Vision Simulation of Diffractive Bifocal and Trifocal Intraocular Lenses
Brezna, Wolfgang; Lux, Kirsten; Dragostinoff, Nikolaus; Krutzler, Christian; Plank, Nicole; Tobisch, Rainer; Boltz, Agnes; Garhöfer, Gerhard; Told, Reinhard; Witkowska, Katarzyna; Schmetterer, Leopold
2016-01-01
Purpose The visual performance of monofocal, bifocal, and trifocal intraocular lenses was evaluated by human individuals using a vision simulator device. This allowed investigation of the visual impression after cataract surgery, without the need actually to implant the lenses. Methods The randomized, double-masked, three-way cross-over study was conducted on 60 healthy male and female subjects aged between 18 and 35 years. Visual acuity (Early Treatment Diabetic Retinopathy Study; ETDRS) and contrast sensitivity tests (Pelli-Robson) under different lighting conditions (luminosities from 0.14–55 cd/m2, mesopic to photopic) were performed at different distances. Results Visual acuity tests showed no difference for corrected distance visual acuity data of bi- and trifocal lens prototypes (P = 0.851), but better results for the trifocal than for the bifocal lenses at distance corrected intermediate (P = 0.021) and distance corrected near visual acuity (P = 0.044). Contrast sensitivity showed no differences between bifocal and trifocal lenses at the distant (P = 0.984) and at the near position (P = 0.925), but better results for the trifocal lens at the intermediate position (P = 0.043). Visual acuity and contrast sensitivity showed a strong dependence on luminosity (P < 0.001). Conclusions At all investigated distances and all lighting conditions, the trifocal lens prototype often performed better, but never worse than the bifocal lens prototype. Translational Relevance The vision simulator can fill the gap between preclinical lens development and implantation studies by providing information of the perceived vision quality after cataract surgery without implantation. This can reduce implantation risks and promotes the development of new lens concepts due to the cost effective test procedure. PMID:27777828
Linz, Katharina; Attia, Mary S A; Khoramnia, Ramin; Tandogan, Tamer; Kretz, Florian T; Auffarth, Gerd Uwe
2016-08-01
To evaluate functional results and reading performance using the Salzburg Reading Desk after implantation of a sector-shaped near-embedded, rotational asymmetrical multifocal intraocular lens (IOL) and a multifocal toric IOL with a +3.00 diopter (D) near addition. In a prospective study, the LentisMplus and Mplus toric IOLs (Oculentis GmbH, Berlin, Germany) were implanted in 34 eyes of 18 patients at the University Eye Hospital of Heidelberg. Uncorrected and corrected distance visual acuity (UDVA, CDVA) and uncorrected and corrected near visual acuity (UNVA, CNVA) were evaluated using standardized visual acuity charts (ETDRS). The Salzburg Reading Desk was used to analyze unilateral and bilateral uncorrected and corrected reading acuity, reading distance, reading speed, and the smallest log-scaled print size that could be read effectively at a set (40 cm/80 cm) and subjective chosen near and intermediate distance. Postoperatively, the median UDVA was 0.08 logMAR (20/25 Snellen) and the median CDVA was 0.01 logMAR (20/20 Snellen). The median UNVA was 0.12 logMAR (20/25 Snellen) and the median CNVA was 0.03 logMAR (20/20 Snellen). The median uncorrected reading acuity measured with the Salzburg Reading Desk for near distance at 40 cm was 0.18 logMAR (20/32 Snellen). The subjectively preferred near distance was 39 cm and revealed similar visual acuity results. The best reading acuity for intermediate distance with a median of 0.22 logMAR (20/32 Snellen) was achieved at a median distance of 62 cm. Reading performance of the multifocal IOL corresponded for near standardized and individual distance, whereas reading function was better at the patient's preferred intermediate distance. [J Refract Surg. 2016;32(8):526-532.]. Copyright 2016, SLACK Incorporated.
Method for Correcting Control Surface Angle Measurements in Single Viewpoint Photogrammetry
NASA Technical Reports Server (NTRS)
Burner, Alpheus W. (Inventor); Barrows, Danny A. (Inventor)
2006-01-01
A method of determining a corrected control surface angle for use in single viewpoint photogrammetry to correct control surface angle measurements affected by wing bending. First and second visual targets are spaced apart &om one another on a control surface of an aircraft wing. The targets are positioned at a semispan distance along the aircraft wing. A reference target separation distance is determined using single viewpoint photogrammetry for a "wind off condition. An apparent target separation distance is then computed for "wind on." The difference between the reference and apparent target separation distances is minimized by recomputing the single viewpoint photogrammetric solution for incrementally changed values of target semispan distances. A final single viewpoint photogrammetric solution is then generated that uses the corrected semispan distance that produced the minimized difference between the reference and apparent target separation distances. The final single viewpoint photogrammetric solution set is used to determine the corrected control surface angle.
Stanca, Horia Tudor; Munteanu, Mihnea; Jianu, Dragoş Cătălin; Motoc, Andrei Gheorghe Marius; Jecan, Cristian Radu; Tăbăcaru, Bogdana; Stanca, Simona; Preda, Maria Alexandra
2018-01-01
To evaluate the predictability, efficacy and safety of Femtosecond-laser-assisted in situ keratomileusis (LASIK) procedure for mixed astigmatism. We prospectively evaluated for 12 months 74 eyes (52 patients) with mixed astigmatism that underwent Femtosecond-LASIK treatment. The preoperative mean refractive sphere value was +1.879±1.313 diopters (D) and the mean refractive cylinder value was -4.169±1.091 D. The anterior corneal flap was cut using the VisuMax® femtosecond laser and then the stromal ablation was done using the MEL® 80 excimer laser. Mean age was 30.22±6.421 years with 61.53% female patients. Postoperative spherical equivalent at 12 months was within ±0.5D of emmetropia in 75.8% of eyes and within ±1D in 97.3% of eyes. Postoperative uncorrected distance visual acuity was equivalent to or better than the preoperative corrected distance visual acuity in 91.9% of eyes. Compared to the preoperative corrected distance visual acuity (CDVA), 8.1% of eyes gained one line, 2.7% gained two lines and 2.7% gained three lines of visual acuity. Femtosecond-LASIK using the VisuMax®-MEL® 80 platform appears to have safe, effective and predictable results in mixed astigmatic eyes. The results are impressive for high refractive error treatment and for improvement of both uncorrected and corrected distance visual acuity.
Ramón, María L; Piñero, David P; Pérez-Cambrodí, Rafael J
2012-02-01
To examine the visual performance of a rotationally asymmetric multifocal intraocular lens (IOL) by correlating the defocus curve of the IOL-implanted eye with the intraocular aberrometric profile and impact on the quality of life. A prospective, consecutive, case series study including 26 eyes from 13 patients aged between 50 and 83 years (mean: 65.54±7.59 years) was conducted. All patients underwent bilateral cataract surgery with implantation of a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 MF30, Oculentis GmbH). Distance and near visual acuity outcomes, intraocular aberrations, defocus curve, and quality of life (assessed using the National Eye Institute Visual Functioning Questionnaire-25) were evaluated postoperatively (mean follow-up: 6.42±2.24 months). A significant improvement in distance visual acuity was found postoperatively (P<.01). Mean postoperative logMAR distance-corrected near visual acuity was 0.19±0.12 (∼20/30). Corrected distance visual acuity and near visual acuity of 20/20 or better were achieved by 30.8% and 7.7% of eyes, respectively. Of all eyes, 96.2% had a postoperative addition between 0 and 1.00 diopter (D). The defocus curve showed two peaks of maximum visual acuity (0 and 3.00 D of defocus), with an acceptable range of intermediate vision. LogMAR visual acuity corresponding to near defocus was directly correlated with some higher order intraocular aberrations (r⩾0.44, P⩽.04). Some difficulties evaluated with the quality of life test correlated directly with near and intermediate visual acuity (r⩾0.50, P⩽.01). The Lentis Mplus multifocal IOL provides good distance, intermediate, and near visual outcomes; however, the induced intraocular aberrometric profile may limit the potential visual benefit. Copyright 2012, SLACK Incorporated.
Ganesh, Sri; Brar, Sheetal; Pawar, Archana
2017-01-01
Purpose To study the long-term visual and refractive outcomes and evaluate patient satisfaction after bilateral implantation of trifocal intraocular lenses (IOLs). Setting Nethradhama Superspeciality Eye Hospital, Bangalore. Design Prospective, nonrandomized study. Methods Eligible patients undergoing bilateral phacoemulsification with trifocal IOL implantation were included. Follow-up examinations were conducted at day 1, 1 week, 1 month, 6 months, and 12 months. Postoperatively, 1 month onward evaluation of uncorrected and distance-corrected far and near visual acuity; reading acuity and reading speeds (using Salzburg Reading Desk) at 70, 80, and 90 cm; contrast sensitivity; defocus curves; and patient satisfaction was carried out. Results Fifty eyes from 25 patients with a mean age of 58±13.44 years were included. All eyes showed significant improvement in spherical equivalent, uncorrected distance visual acuity, corrected distance visual acuity, uncorrected near visual acuity, and corrected near visual acuity at 1 month compared to preoperative values (P<0.05), with no significant change in these parameters thereafter until the last follow-up (P>0.05). At 12 months, mean uncorrected reading acuities and reading speeds at 70, 80, and 90 cm were in the range of 0.09–0.04 logMAR units and 153.6–169.0 words per minute, respectively, with significantly better results at 80 cm. Five eyes underwent YAG laser capsulotomy for early posterior capsule opacification (PCO) at a mean follow-up of 7.2±2.9 months. Contrast sensitivity scores at 12 months were comparable to 1 month (P>0.05 for all spatial frequencies). All patients reported good tolerance and 100% independence from spectacles for all activities. Conclusion Trifocal IOLs provided excellent unaided vision at all distances. Reading performance was good through the complete intermediate distance range. PCO occurrence and subsequent YAG capsulotomy did not affect the long-term visual outcomes. PMID:28860693
Sáles, Christopher S; Manche, Edward E
2014-01-01
Background To compare wavefront (WF)-guided and WF-optimized laser in situ keratomileusis (LASIK) in hyperopes with respect to the parameters of safety, efficacy, predictability, refractive error, uncorrected distance visual acuity, corrected distance visual acuity, contrast sensitivity, and higher order aberrations. Methods Twenty-two eyes of eleven participants with hyperopia with or without astigmatism were prospectively randomized to receive WF-guided LASIK with the VISX CustomVue S4 IR or WF-optimized LASIK with the WaveLight Allegretto Eye-Q 400 Hz. LASIK flaps were created using the 150-kHz IntraLase iFS. Evaluations included measurement of uncorrected distance visual acuity, corrected distance visual acuity, <5% and <25% contrast sensitivity, and WF aberrometry. Patients also completed a questionnaire detailing symptoms on a quantitative grading scale. Results There were no statistically significant differences between the groups for any of the variables studied after 12 months of follow-up (all P>0.05). Conclusion This comparative case series of 11 subjects with hyperopia showed that WF-guided and WF-optimized LASIK had similar clinical outcomes at 12 months. PMID:25419115
Kretz, Florian T A; Bastelica, Antoine; Carreras, Humberto; Ferreira, Tiago; Müller, Matthias; Gerl, Matthias; Gerl, Ralf; Saeed, Manzar; Schmickler, Stefanie; Auffarth, Gerd U
2015-03-01
To evaluate the clinical outcome in eyes with significant corneal astigmatism after cataract surgery with implantation of a new diffractive multifocal toric intraocular lens (IOL). Prospective, non-randomised multicentre clinical study including 57 eyes of 38 consecutive patients with an age between 37 and 84 years that underwent cataract surgery with implantation of the toric multifocal IOL Tecnis ZMT (Abbott Medical Optics, Santa Ana, California, USA). Changes in uncorrected and corrected logMAR distance, intermediate and near visual acuity ((uncorrected distance visual acuity (UDVA), uncorrected intermediate visual acuity (UIVA) uncorrected near visual acuity (UNVA), corrected distance visual acuity (CDVA), corrected near visual acuity) and manifest refraction were evaluated during a 2-4 month follow-up. Additionally, patients were asked about photic phenomena and spectacle dependence. The surgeons subjectively assessed various aspects of the surgery. A significant improvement in CDVA was observed postoperatively (p<0.01), with a significant reduction in manifest cylinder (p<0.01). Mean postoperative binocular UDVA and UNVA were 0.04±0.10 and 0.06±0.12, respectively. Monocular UDVA and UNVA was 0.20 or better in 85.4% and 87.0% of eyes, respectively. Mean binocular logMAR UIVA was 0.21±0.20. Only 10.5% of patients required postoperative correction for near or intermediate distance. The incidence of moderate to severe photic phenomena was limited. Surgeons defined the IOL implantation in most cases as easy or very easy, with a satisfaction rate with the procedure of 84%. The implantation of the multifocal toric IOL is a safe procedure that provides a very good visual rehabilitation in eyes with corneal astigmatism. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Shao, Dewang; He, Shouzhi
2014-02-01
To systematic review the effectiveness of refractive multifocal intraocular lens (MIOL) versus diffractive MIOL in the treatment of cataract. Randomized controlled trials comparing refractive MIOL with diffractive MIOL were identified by searching PubMed (1966 to May, 2013), EMbase (1980 to May, 2013), Medline (1966 to May, 2013), and The Cochrane Library (Issue 1, 2013). We also hand-searched related journals. All the searches were restricted in English or Chinese. Methodological quality of randomized controlled trials (RCT) was evaluated by simple evaluate method that recommended by the Cochrane Collaboration. Data extracted by two reviewers with designed extraction form. RevMan software (release 5.2) was used for data management and analysis. A total of 11 trials (1460 eyes) were included for systematic review. Subgroup analyses were used according to different model comparison of MIOL. The results showed a significant difference in the mean of the uncorrected distance visual acuity (UCDVA) and the uncorrected intermediate visual acuity (UCIVA) in the refractive MIOL group with WMD -0.04, 95%CI -0.06 to -0.03 (P < 0.01) and WMD -0.05, 95%CI -0.09 to -0.02 (P = 0.001). It showed a significantly difference in the mean of the uncorrected near visual acuity (UCNVA), complete spectacle independent rate, halo rate and glare rate in the diffractive MIOL group with WMD 0.11, 95%CI 0.08 to 0.15 (P < 0.01), WMD 2.98, 95%CI 2.17 to 4.09 (P < 0.01), WMD 1.52, 95%CI 1.14 to 2.04 (P = 0.004) and WMD 1.27, 95%CI 1.07 to 1.50 (P = 0.005). There was no significant difference between the two groups in the mean of the best corrected distance visual acuity (BCDVA), the best distance corrected intermediate visual acuity (BDCIVA), the best distance corrected near visual acuity (BDCNVA) and the best corrected near visual acuity (BCNVA) with WMD -0.01, 95%CI -0.03 to 0.01 (P = 0.45), WMD -0.06, 95%CI -0.15 to 0.03 (P = 0.18), WMD 0.08, 95%CI -0.01 to 0.17 (P = 0.09) and WMD -0.02, 95%CI -0.26 to 0.23 (P = 0.88). Patients implanted with refractive MIOL show better uncorrected distance and intermediate visual acuity; patients implanted with diffractive MIOL show better uncorrected near visual acuity with less likely to appear light halo, glare and other visual adverse reactions. As for spectacles correction cases, patients implanted with diffractive or refractive MIOL have considerable performances in the far, middle, near visual acuity.
Designing multifocal corneal models to correct presbyopia by laser ablation
NASA Astrophysics Data System (ADS)
Alarcón, Aixa; Anera, Rosario G.; Del Barco, Luis Jiménez; Jiménez, José R.
2012-01-01
Two multifocal corneal models and an aspheric model designed to correct presbyopia by corneal photoablation were evaluated. The design of each model was optimized to achieve the best visual quality possible for both near and distance vision. In addition, we evaluated the effect of myosis and pupil decentration on visual quality. The corrected model with the central zone for near vision provides better results since it requires less ablated corneal surface area, permits higher addition values, presents stabler visual quality with pupil-size variations and lower high-order aberrations.
Outcomes of presbyopia-correcting intraocular lenses after laser in situ keratomileusis.
Chow, Sharon S W; Chan, Tommy C Y; Ng, Alex L K; Kwok, Alvin K H
2018-03-28
Laser in situ keratomileusis (LASIK) is the most common refractive surgery in young patients, which aims at providing a clear distance vision without the use of spectacles. With time, these patients develop symptomatic cataract, which affects activities of daily living, and to improve visual acuity, intraocular lens (IOL) implantation can be considered. In post-myopic LASIK patients, to allow continuation of spectacle independence, the implantation of presbyopia-correcting IOLs is a suitable option. The purpose of this retrospective case series is to report the visual outcome and quality in post-myopic LASIK eyes after the implantation of AT LISA tri839MP IOL. Twenty eyes of 13 patients with history of myopic LASIK within 20 years underwent phacoemulsification by one single surgeon. All eyes were implanted with AT LISA tri839PMP IOL, and their outcomes were evaluated at 6 months postoperation. The mean postoperative uncorrected distance visual acuity (VA) is 0.28 ± 0.29, while the corrected distance VA is 0.06 ± 0.14. The mean postoperative uncorrected near VA is 0.02 ± 0.05, while the corrected near VA is 0.01 ± 0.02. The mean postoperative manifest refraction spherical equivalent (SE) is - 0.92 ± 0.76D. There is a statistically significant difference between the preoperative and postoperative refraction (p = 0.02), which shows a postoperative myopic shift. There is also a statistically significant difference between the mean targeted SE and postoperative manifest refraction SE (p = 0.00). Only one out of 20 eyes (5%) reported halo and glare symptoms. Ten out of 20 eyes (50%) are able to achieve spectacles independence. In conclusion, in post-myopic LASIK eyes, AT LISA tri839MP provides a good visual outcome at both near and distance, but is more predictable at near than at distance. There is a myopic shift in the postoperative SE. Visual quality is satisfactory and has not been exacerbated. Most patients can remain to be spectacles free at all distances.
Code of Federal Regulations, 2013 CFR
2013-07-01
... lenses than by eyeglass lenses, as corrected by contact lenses. (3) In any case where the examiner... these cases, evaluate based on corrected distance vision adjusted to one step poorer than measured. (4...
Code of Federal Regulations, 2012 CFR
2012-07-01
... lenses than by eyeglass lenses, as corrected by contact lenses. (3) In any case where the examiner... these cases, evaluate based on corrected distance vision adjusted to one step poorer than measured. (4...
Code of Federal Regulations, 2014 CFR
2014-07-01
... lenses than by eyeglass lenses, as corrected by contact lenses. (3) In any case where the examiner... these cases, evaluate based on corrected distance vision adjusted to one step poorer than measured. (4...
Distance versus near visual acuity in amblyopia
Christoff, Alex; Repka, Michael X.; Kaminski, Brett M.; Holmes, Jonathan M.; Ch, B
2011-01-01
Purpose There are conflicting reports about whether distance and near visual acuity are similar in eyes with amblyopia. The purpose of this study is to compare monocular distance visual acuity with near visual acuity in amblyopic eyes of children. Methods Subjects 2 to 6 years of age were evaluated in a randomized trial of amblyopia therapy for moderate amblyopia (20/40 to 20/80) due to anisometropia, strabismus, or both. Prior to initiating the protocol-prescribed therapy, subjects had best-corrected visual acuity measured with standardized protocols at 3 meters and 0.4 meters using single-surrounded HOTV optotypes. Results A total of 129 subjects were included. The mean amblyopic eye visual acuity was similar at distance and near (mean, 0.45 logMAR at distance versus 0.45 logMAR at near; mean difference, +0.00, 95% CI, −0.03 to 0.03). Of the 129 subjects, 86 (67%) tested within one line at distance and near, 19 (15%) tested more than one logMAR line better at distance, and 24 (19%) tested more than one logMAR line better at near. The mean visual acuity difference between distance and near did not differ by cause of amblyopia, age, or spherical equivalent refractive error. Conclusions We found no systematic difference between distance and near visual acuity in 2- to 6-year-old children with moderate amblyopia associated with strabismus and/or anisometropia. Individual differences between distance and near visual acuity are likely due to test–retest variability. PMID:21907115
ERIC Educational Resources Information Center
Beauchamp, Darrell G.; And Others
This document contains selected conference papers all relating to visual literacy. The topics include: process issues in visual literacy; interpreting visual statements; what teachers need to know; multimedia presentations; distance education materials for correctional use; visual culture; audio-visual interaction in desktop multimedia; the…
Comparison of the visual results after SMILE and femtosecond laser-assisted LASIK for myopia.
Lin, Fangyu; Xu, Yesheng; Yang, Yabo
2014-04-01
To perform a comparative clinical analysis of the safety, efficacy, and predictability of two surgical procedures (ie, small incision lenticule extraction [SMILE] and femtosecond laser-assisted LASIK [FS-LASIK]) to correct myopia. Sixty eyes of 31 patients with a mean spherical equivalent of -5.13 ± 1.75 diopters underwent myopia correction with the SMILE procedure. Fifty-one eyes of 27 patients with a mean spherical equivalent of -5.58 ± 2.41 diopters were treated with the FS-LASIK procedure. Postoperative uncorrected and corrected distance visual acuity, manifest refraction, and higher-order aberrations were analyzed statistically at 1 and 3 months postoperatively. No statistically significant differences were found at 1 and 3 months in parameters that included the percentage of eyes with an uncorrected distance visual acuity of 20/20 or better (P = .556, .920) and mean spherical equivalent refraction (P = .055, .335). At 1 month, 4 SMILE-treated eyes and 1 FS-LASIK-treated eye lost one or more line of visual acuity (P = .214, chi-square test). At 3 months, 2 SMILE-treated eyes lost one or more line of visual acuity, whereas all FS-LASIK-treated eyes had an unchanged or corrected distance visual acuity. Higher-order aberrations and spherical aberration were significantly lower in the SMILE group than the FS-LASIK group at 1 (P = .007, .000) and 3 (P = .006, .000) months of follow-up. SMILE and FS-LASIK are safe, effective, and predictable surgical procedures to treat myopia. SMILE has a lower induction rate of higher-order aberrations and spherical aberration than the FS-LASIK procedure. Copyright 2014, SLACK Incorporated.
Gundersen, Kjell G; Potvin, Rick
2017-01-01
To compare two different diffractive trifocal intraocular lens (IOL) designs, evaluating longer-term refractive outcomes, visual acuity (VA) at various distances, low contrast VA and quality of vision. Patients with binocularly implanted trifocal IOLs of two different designs (FineVision [FV] and Panoptix [PX]) were evaluated 6 months to 2 years after surgery. Best distance-corrected and uncorrected VA were tested at distance (4 m), intermediate (80 and 60 cm) and near (40 cm). A binocular defocus curve was collected with the subject's best distance correction in place. The preferred reading distance was determined along with the VA at that distance. Low contrast VA at distance was also measured. Quality of vision was measured with the National Eye Institute Visual Function Questionnaire near subset and the Quality of Vision questionnaire. Thirty subjects in each group were successfully recruited. The binocular defocus curves differed only at vergences of -1.0 D (FV better, P =0.02), -1.5 and -2.00 D (PX better, P <0.01 for both). Best distance-corrected and uncorrected binocular vision were significantly better for the PX lens at 60 cm ( P <0.01) with no significant differences at other distances. The preferred reading distance was between 42 and 43 cm for both lenses, with the VA at the preferred reading distance slightly better with the PX lens ( P =0.04). There were no statistically significant differences by lens for low contrast VA ( P =0.1) or for quality of vision measures ( P >0.3). Both trifocal lenses provided excellent distance, intermediate and near vision, but several measures indicated that the PX lens provided better intermediate vision at 60 cm. This may be important to users of tablets and other handheld devices. Quality of vision appeared similar between the two lens designs.
New pinhole sulcus implant for the correction of irregular corneal astigmatism.
Trindade, Claudio C; Trindade, Bruno C; Trindade, Fernando C; Werner, Liliana; Osher, Robert; Santhiago, Marcony R
2017-10-01
To evaluate the effect on visual acuity of the implantation of a new intraocular pinhole device (Xtrafocus) in cases of irregular corneal astigmatism with significant visual impairment. University of São Paulo, São Paulo, Brazil. Prospective case series. Pseudophakic eyes of patients with irregular corneal astigmatism were treated with the pinhole device. The causes of irregular corneal astigmatism were keratoconus, post radial keratotomy (RK), post-penetrating keratoplasty (PKP), and traumatic corneal laceration. The device was implanted in the ciliary sulcus in a piggyback configuration to minimize the effect of corneal aberrations. Preoperative and postoperative visual parameters were compared. The main outcome variables were manifest refraction, uncorrected and corrected distance and near visual acuities, subjective patient satisfaction, and intraoperative and postoperative adverse events and complications. Twenty-one patients (ages 35 to 85 years) were included. There was statistically significant improvement in uncorrected and corrected (CDVA) distance visual acuities. The median CDVA improved from 20/200 (range 20/800 to 20/60) preoperatively to 20/50 (range 20/200 to 20/20) in the first month postoperatively and remained stable over the following months. Manifest refraction remained unchanged, while a subjective visual performance questionnaire revealed perception of improvement in all the tested working distances. No major complication was observed. One case presented with decentration of the device, which required an additional surgical intervention. The intraocular pinhole device performed well in patients with irregular astigmatism caused by keratoconus, RK, PKP, and traumatic corneal laceration. There was marked improvement in visual function, with high patient satisfaction. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Pedrotti, Emilio; Mastropasqua, Rodolfo; Bonetto, Jacopo; Demasi, Christian; Aiello, Francesco; Nucci, Carlo; Mariotti, Cesare; Marchini, Giorgio
2017-07-17
The aim of the current study was to compare the quality of vision, contrast sensitivity and patient satisfaction with a biaspheric, segmented, rotationally asymmetric IOL (Lentis Comfort LS-313 MF 15-Oculentis GmbH, Berlin, Germany) as opposed to those of a monofocal IOL. This prospective single-blind comparative study included two groups of patients affected by bilateral senile cataract who underwent lens extraction and IOL implantation. The first group received a bilateral implantation of a monofocal IOL, and the second group received a bilateral implantation of the Comfort IOL. Twelve months after surgery uncorrected and corrected visual acuity at different distances (30, 50, 70 cm and 4 m), defocus curve and contrast sensitivity were assessed. Patient's satisfaction and spectacle independence were evaluated by mean of the NEI RQL-42 questionnaire. No significant differences were found between the groups in terms of near vision. The group of patients implanted with a Comfort IOL obtained the best results at intermediate distances (50 and 70 cm P < .001). Both groups showed an excellent uncorrected distance visual acuity (4 m). No statistically significant differences were found in terms of corrected near, intermediate and distance visual acuity. Concerning contrast sensitivity, no statistically significant differences between the groups were observed at any cycles per degree. The NEI RQL-42 questionnaire showed statistically significant differences between the group for "near vision" (P = .015), "dependence on correction" (P = .048) and "suboptimal correction" (P < .001) subscales. Our findings indicated that the Comfort IOL +1.5 D provides a good intermediate spectacle independence together with a high quality of vision, with a low amount of subjective symptoms and a contrast sensitivity similar to those obtained with a monofocal IOL.
Toric Intraocular Lens Outcomes in Patients With Glaucoma.
Brown, Reay H; Zhong, Le; Bozeman, Caroline W; Lynch, Mary G
2015-06-01
To report the outcomes of toric intraocular lens implantation in patients with glaucoma and corneal astigmatism. One hundred twenty-six eyes of 87 patients with glaucoma and corneal astigmatism that underwent cataract surgery with an AcrySof toric intraocular lens (Alcon Laboratories, Inc., Fort Worth, TX) implant were selected for this single-center, retrospective case series. Corrected distance visual acuity, intraocular pressure, and refractive astigmatism were measured in each eye preoperatively and postoperatively. Uncorrected distance visual acuity and toric alignment were measured postoperatively. The uncorrected distance visual acuity was 0.04 ± 0.08 logMAR (20/22 Snellen) for all eyes. Ninety-eight percent of all eyes achieved an uncorrected distance visual acuity of 20/40 or better, with 76% achieving 20/25 or better and 47% achieving 20/20. The corrected distance visual acuity for all eyes was 0.01 ± 0.03 logMAR (20/20.5 Snellen) postoperatively. The refractive cylinder improved from 1.47 ± 1.10 diopters preoperatively to 0.31 ± 0.37 diopters postoperatively. The residual refractive cylinder was 1.00 diopter or less in 97% of eyes, 0.75 diopters or less in 90% of eyes, and 0.50 diopters or less in 83% of eyes. Mean misalignment was 4.4° ± 5.1°. Intraocular pressure decreased by a mean of 2.3 ± 3.3 mm Hg following the surgery. Toric intraocular lenses can reliably reduce astigmatism and improve uncorrected vision in eyes with cataract and glaucoma. Copyright 2015, SLACK Incorporated.
Fisher, Diana E; Shrager, Sandi; Shea, Steven J; Burke, Gregory L; Klein, Ronald; Wong, Tien Y; Klein, Barbara E; Cotch, Mary Frances
2015-01-01
To describe the prevalence of visual impairment and examine its association with demographic, socioeconomic, and health characteristics in the Multi-Ethnic Study of Atherosclerosis (MESA) cohort. Visual acuity data were obtained from 6134 participants, aged 46-87 years at time of examination between 2002 and 2004 (mean age 64 years, 47.6% male), from six communities in the United States. Visual impairment was defined as presenting visual acuity 20/50 or worse in the better-seeing eye. Risk factors were included in multivariable logistic regression models to determine their impact on visual impairment for men and women in each racial/ethnic group. Among all participants, 6.6% (n = 421) had visual impairment, including 5.6% of men (n = 178) and 7.5% of women (n = 243). Prevalence of impairment ranged from 4.2% (n = 52) and 6.0% (n = 77) in white men and women, respectively, to 7.6% (n = 37) and 11.6% (n = 44) in Chinese men and women, respectively. Older age was significantly associated with visual impairment in both men and women, particularly in those with lower socioeconomic status, but the effects of increasing age were more pronounced in men. Two-thirds of participants already wore distance correction, and not unexpectedly, a lower prevalence of visual impairment was seen in this group; however, 2.4% of men and 3.5% of women with current distance correction had correctable visual impairment, most notably among seniors. Even in the U.S. where prevalence of refractive correction is high, both visual impairment and uncorrected refractive error represent current public health challenges.
Fisher, Diana E.; Shrager, Sandi; Shea, Steven J.; Burke, Gregory L.; Klein, Ronald; Wong, Tien Y.; Klein, Barbara E; Cotch, Mary Frances
2016-01-01
Purpose To describe the prevalence of visual impairment and examine its association with demographic, socioeconomic, and health characteristics in the Multi-Ethnic Study of Atherosclerosis (MESA) cohort. Methods Visual acuity data was obtained from 6134 participants, aged 46 to 87 years old at time of examination between 2002 and 2004 (mean age 64 years, 47.6% male), from six communities in the United States (U.S.). Visual impairment was defined as a presenting visual acuity of 20/50 or worse in the better-seeing eye. Risk factors were included in multivariable logistic regression models to determine their impact on visual impairment for men and women in each racial/ethnic group. Results Among all participants, 6.6% (N=421) had visual impairment, including 5.6% (N=178) of men and 7.5% (N=243) of women. Prevalence of impairment ranged from 4.2% (N=52) and 6.0% (N=77) in White men and women, respectively, to 7.6% (N=37) and 11.6% (N=44) in Chinese men and women, respectively. Older age was significantly associated with visual impairment in both men and women, particularly in those with lower socioeconomic status, but the effects of increasing age were more pronounced in men. Two-thirds of participants already wore distance correction and not unexpectedly, lower prevalence of visual impairment was seen in this group; however, 2.4% of men and 3.5% of women with current distance correction had correctable visual impairment, most notably among seniors. Conclusion Even in the United States where prevalence of refractive correction is high, both visual impairment and uncorrected refractive error represent current public health challenges. PMID:26395659
[Work with visual demands. Assumption of responsibility for optical correction by the employer].
Hermans, G
2004-01-01
Comparison of visual demands of work in a traditional office to those of work in an office equiped with a screen. Description of problems of vision when focusing the eye to various distances and fixing it in various directions. Range of possibilities for optical correction for work with a screen (monofocal, bifocal, progressive or for reading), specifying among the optical corrections those which are exclusively reserved for this activity and should become the employer's responsibility.
Nowak, Michal S; Gos, Roman; Jurowski, Piotr; Smigielski, Janusz
2009-07-01
To evaluate the prevalence of correctable and non-correctable visual impairment in a representative sample of young males commissioned for Military Service in Poland. Data concerning vision status was retrospectively reviewed in 969 subjects of European Caucasian origin, most of whom live and have lived in Poland. They were selected from the original database comprising 105017 subjects examined in the period 1993-2004. Based on the age of subjects they were divided into two groups; group I aged 18-24 and group II aged 25-34 years. Visual impairment was defined as distance visual acuity of <20/40 in one or both eyes. Non-correctable impairment was defined as that which was not eliminated by refractive correction. A total of 1938 eyes of 969 white males were examined. There was statistically significant association between rates of visual impairment and increasing age (p < 0.001). Visual impairment was found in 128 (13.2%) subjects in at least one eye. Non-correctable visual impairment was found in 12 (1.2%) subjects. Amblyopia was the main cause, accounting for eight cases (66.67%). Correctable visual impairment was found in the remaining 116 (12.0%) patients. Among them myopia was the most common refractive error and accounted for 75.8%. Differences between age-specific rates of refractive errors were statistically significant (p = 0.003). Appropriate refractive correction improves visual acuity in most subjects presenting with visual impairment. There was a relatively low prevalence of non-correctable visual impairment in a population of young adults in Poland, and this was mainly due to amblyopia.
Comparison of vision through surface modulated and spatial light modulated multifocal optics.
Vinas, Maria; Dorronsoro, Carlos; Radhakrishnan, Aiswaryah; Benedi-Garcia, Clara; LaVilla, Edward Anthony; Schwiegerling, Jim; Marcos, Susana
2017-04-01
Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near.
Comparison of vision through surface modulated and spatial light modulated multifocal optics
Vinas, Maria; Dorronsoro, Carlos; Radhakrishnan, Aiswaryah; Benedi-Garcia, Clara; LaVilla, Edward Anthony; Schwiegerling, Jim; Marcos, Susana
2017-01-01
Spatial-light-modulators (SLM) are increasingly used as active elements in adaptive optics (AO) systems to simulate optical corrections, in particular multifocal presbyopic corrections. In this study, we compared vision with lathe-manufactured multi-zone (2-4) multifocal, angularly and radially, segmented surfaces and through the same corrections simulated with a SLM in a custom-developed two-active-element AO visual simulator. We found that perceived visual quality measured through real manufactured surfaces and SLM-simulated phase maps corresponded highly. Optical simulations predicted differences in perceived visual quality across different designs at Far distance, but showed some discrepancies at intermediate and near. PMID:28736655
DOT National Transportation Integrated Search
1977-03-01
Visual acuity was determined at the intermediate range for older individuals with various combinations of ocular refractive error (nine subcategories) and accommodative power (three subcategories). Subjects (N=249) read numerals ranging in size to me...
Urlic, Iris; Verzak, Željko; Vranic, Dubravka Negovetic
2016-01-01
Aim The purpose of this study was to compare near visual acuity of dentists without optical aids (VSC) with near visual acuity of those using the Galilean telescope system (VGA2) with magnification of x 2.5, and the distance of 350 mm in simulated clinical conditions. Methods The study included 46 dentists (visual acuity 1.0 without correction). A visual acuity testing was carried out using a miniaturized Snellen visual acuity chart which was placed in the cavity of molar teeth mounted in a phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1) without correction at a distance of 300-400 mm (VSC); 2) with Galilean loupes with magnification of x2.5, focal length of 350mm. Results The distributions of near visual acuity recorded using VSC and VGA2, 5 systems were compared by the Wilcoxon Signed Rank test. The results obtained by Wilcoxon Signed Rank test pointed to a statistically significant difference in the distribution of recorded visual acuity between the VSC and VGA2 optical systems (W = - 403.5; p <0.001). Conclusion If using the VGA2, 5 systems, higher values of the near visual acuity were recorded and subsequently compared to near visual acuity without magnifying aids (VSC). PMID:27847397
Urlic, Iris; Verzak, Željko; Vranic, Dubravka Negovetic
2016-09-01
The purpose of this study was to compare near visual acuity of dentists without optical aids (VSC) with near visual acuity of those using the Galilean telescope system (VGA2) with magnification of x 2.5, and the distance of 350 mm in simulated clinical conditions. The study included 46 dentists (visual acuity 1.0 without correction). A visual acuity testing was carried out using a miniaturized Snellen visual acuity chart which was placed in the cavity of molar teeth mounted in a phantom head in simulated clinical conditions. Near visual acuity for the vicinity was examined: 1) without correction at a distance of 300-400 mm (VSC); 2) with Galilean loupes with magnification of x2.5, focal length of 350mm. The distributions of near visual acuity recorded using VSC and VGA2, 5 systems were compared by the Wilcoxon Signed Rank test. The results obtained by Wilcoxon Signed Rank test pointed to a statistically significant difference in the distribution of recorded visual acuity between the VSC and VGA2 optical systems (W = - 403.5; p <0.001). If using the VGA2, 5 systems, higher values of the near visual acuity were recorded and subsequently compared to near visual acuity without magnifying aids (VSC).
Exploring the Relationship Between Eye Movements and Electrocardiogram Interpretation Accuracy
NASA Astrophysics Data System (ADS)
Davies, Alan; Brown, Gavin; Vigo, Markel; Harper, Simon; Horseman, Laura; Splendiani, Bruno; Hill, Elspeth; Jay, Caroline
2016-12-01
Interpretation of electrocardiograms (ECGs) is a complex task involving visual inspection. This paper aims to improve understanding of how practitioners perceive ECGs, and determine whether visual behaviour can indicate differences in interpretation accuracy. A group of healthcare practitioners (n = 31) who interpret ECGs as part of their clinical role were shown 11 commonly encountered ECGs on a computer screen. The participants’ eye movement data were recorded as they viewed the ECGs and attempted interpretation. The Jensen-Shannon distance was computed for the distance between two Markov chains, constructed from the transition matrices (visual shifts from and to ECG leads) of the correct and incorrect interpretation groups for each ECG. A permutation test was then used to compare this distance against 10,000 randomly shuffled groups made up of the same participants. The results demonstrated a statistically significant (α 0.05) result in 5 of the 11 stimuli demonstrating that the gaze shift between the ECG leads is different between the groups making correct and incorrect interpretations and therefore a factor in interpretation accuracy. The results shed further light on the relationship between visual behaviour and ECG interpretation accuracy, providing information that can be used to improve both human and automated interpretation approaches.
Visual and skill effects on soccer passing performance, kinematics, and outcome estimations
Basevitch, Itay; Tenenbaum, Gershon; Land, William M.; Ward, Paul
2015-01-01
The role of visual information and action representations in executing a motor task was examined from a mental representations approach. High-skill (n = 20) and low-skill (n = 20) soccer players performed a passing task to two targets at distances of 9.14 and 18.29 m, under three visual conditions: normal, occluded, and distorted vision (i.e., +4.0 corrective lenses, a visual acuity of approximately 6/75) without knowledge of results. Following each pass, participants estimated the relative horizontal distance from the target as the ball crossed the target plane. Kinematic data during each pass were also recorded for the shorter distance. Results revealed that performance on the motor task decreased as a function of visual information and task complexity (i.e., distance from target) regardless of skill level. High-skill players performed significantly better than low-skill players on both the actual passing and estimation tasks, at each target distance and visual condition. In addition, kinematic data indicated that high-skill participants were more consistent and had different kinematic movement patterns than low-skill participants. Findings contribute to the understanding of the underlying mechanisms required for successful performance in a self-paced, discrete and closed motor task. PMID:25784886
Kretz, Florian T A; Müller, Matthias; Gerl, Matthias; Gerl, Ralf H; Auffarth, Gerd U
2015-08-21
To evaluate binocular visual outcome for near, intermediate and distance compared to monocular visual outcome at the same distances in patients implanted with a diffractive trifocal intraocular lens (IOL). The study comprised of 100 eyes of 50 patients that underwent bilateral refractive lens exchange or cataract surgery with implantation of a multifocal diffractive IOL (AT LISA tri 839MP, Carl Zeiss Meditech, Germany). A complete ophthalmological examination was performed preoperatively and 3 month postoperatively. The main outcome measures were monocular and binocular uncorrected distance (UDVA), corrected distance (CDVA), uncorrected intermediate (UIVA), and uncorrected near visual acuities (UNVA), keratometry, and manifest refraction. The mean age was 59.28 years ± 9.6 [SD] (range 44-79 years), repectively. There was significant improvement in UDVA, UIVA, UNVA and CDVA. Comparing the monocular results to the binocular results there was a statistical significant better binocular outcome in all distances (UDVA p = 0.036; UIVA p < 0.0001; UNVA p = 0.001). The postoperative manifest refraction was in 86 % of patients within ± 0.50 [D]. The trifocal IOL improved near, intermediate, and distance vision compared to preoperatively. In addition a statistical significant increase for binocular visual function in all distances could be found. German Clinical Trials Register (DRKS) DRKS00007837.
Hayashi, Ken; Masumoto, Miki; Takimoto, Minehiro
2015-01-01
To compare visual outcomes between patients with a multifocal toric intraocular lens (IOL) and those with a monofocal toric IOL. Hayashi Eye Hospital, Fukuoka, Japan. Prospective case-control series. Eyes with preoperative corneal astigmatism between 0.75 diopter (D) and 2.82 D scheduled for implantation of a diffractive multifocal toric IOL (Restor SND1T) or monofocal toric IOL (Acrysof SN6AT) were recruited. Three months postoperatively, visual acuity at various distances, contrast visual acuity, and refractive outcomes were examined. Each group comprised 66 eyes (33 patients). Postoperatively, the mean refractive astigmatism decreased to 0.71 D in the multifocal group and 0.74 D in the monofocal group. The mean monocular and binocular uncorrected and corrected near visual acuity at 0.3 m and intermediate visual acuity at 0.5 m were significantly better in the multifocal group than in the monofocal group (P≤.0011). The uncorrected and corrected visual acuities at other distances were similar between groups except at 1.0 m. Binocular photopic and mesopic contrast visual acuities at high to moderate contrasts did not differ significantly between groups; however, acuities at low contrasts were worse in the multifocal group (P≤.0429). Diffractive multifocal toric IOL implantation decreased refractive astigmatism to an acceptable range in eyes with moderate corneal astigmatism and provided useful visual acuity (≥20/40) at any distance and significantly better near and intermediate visual acuity than a monofocal toric IOL. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Lenze, James S.
This paper examines the conceptualization and design of the Pennsylvania Audiographics Distance Education Project's (PADEP) Life Skills and Drug Education Course, and discusses the successes and difficulties of the project based on results from formative evaluation. Educators from Harrisburg, Pennsylvania, developed new courses that could be…
Laíns, Inês; Rosa, Andreia M; Guerra, Marta; Tavares, Cristina; Lobo, Conceição; Silva, Maria F L; Quadrado, Maria J; Murta, Joaquim N
2016-01-01
To analyze the efficacy and safety of topography-guided photorefractive keratectomy (TG-PRK) to treat irregular astigmatism after corneal transplantation. This was a retrospective observational case series. Eyes with irregular astigmatism after penetrating keratoplasty treated with TG-PRK (Allegretto Wave Eye-Q) with the topography-guided customized ablation treatment protocol were included. All treatments had been planned to correct the topographic irregularities, as well as to reduce the refractive error after neutralizing the induced refractive change. Clinical records, treatment plan, and the examinations performed were reviewed and the following data were collected: corrected and uncorrected distance visual acuities; manifest refraction; topographic parameters, and corneal endothelial cell count. We included 31 eyes [30 patients; mean age 45.0 ± 13.4 (SD) years]. At the last postoperative follow-up (mean 9.2 ± 8.2 months), we observed a significant improvement in corrected (P = 0.001) and uncorrected distance visual acuities (P < 0.001). There was a gain of ≥1 uncorrected distance visual acuity line in 96.8% (n = 30) of the eyes. Similarly, the refractive parameters also improved (cylinder P < 0.001; spherical equivalent P = 0.002). At the last visit, 54.8% (n = 17) of the patients presented a spherical equivalent of ±1 D. The 3-mm topographic irregularity also decreased significantly (P < 0.001). There was no significant variation of the corneal endothelial cell count. This is the largest case series of TG-PRK to treat irregular astigmatism in postcorneal transplantation eyes. Our results confirm that TG-PRK is an efficient treatment, associated with significant improvements of both visual acuity and refractive parameters.
Stereoscopic distance perception
NASA Technical Reports Server (NTRS)
Foley, John M.
1989-01-01
Limited cue, open-loop tasks in which a human observer indicates distances or relations among distances are discussed. By open-loop tasks, it is meant tasks in which the observer gets no feedback as to the accuracy of the responses. What happens when cues are added and when the loop is closed are considered. The implications of this research for the effectiveness of visual displays is discussed. Errors in visual distance tasks do not necessarily mean that the percept is in error. The error could arise in transformations that intervene between the percept and the response. It is argued that the percept is in error. It is also argued that there exist post-perceptual transformations that may contribute to the error or be modified by feedback to correct for the error.
Changes in stereoacuity following implantable Collamer lens implantation in patients with myopia
Khokhar, Sudarshan; Gupta, Shikha; Gogia, Varun; Tewari, Ruchir; Agarwal, Tushar
2015-01-01
The study evaluated the impact of implantable Collamer lens (ICL) implantation on stereoacuity in myopes in a retrospective case series. Ninety-five eyes of 48 patients were recruited. Distance and near stereoacuity were measured using distance Randot stereotest and TNO test, respectively, before surgery and at 4 weeks postoperatively. Mean age of the patients was 23.67 ± 3.7 years. Mean uncorrected distance visual acuity (UDVA) was 1.28 ± 0.37 logarithm of the minimum angle of resolution (logMAR) (median: 1.3; range: 0.3–1.8), and median best-corrected distance visual acuity (BDVA) was 0.18 logMAR (range: 0–0.6). There was a significant improvement in both UDVA and BDVA postsurgery (P < 0.001; Wilcoxon signed rank test). The overall improvement in stereopsis was observed in 15/48 (31.25%) and 13/48 (27.10%) subjects for near and distance, respectively, with no significant difference between the two (P = 0.82; Fisher's exact test). Among stereoblind individuals, the odd's ratio for near stereoacuity to improve in comparison to distance stereoacuity was 8.85 (95% confidence interval: 1.68–46.70; P = 0.01). ICL implantation for refractive correction aided stereoacuity improvement in myopes more so for near. PMID:26655005
Huang, Jing; Lu, Wei
2009-09-29
To analyze the effect of LASIK on visual quality of anisometropia, and evaluate its clinical value in the view of visual quality. Prospective observational case series. Assayed the naked vision, glasses-corrected vision and binocular vision of 45 cases with anisometropia >or= 2.25D before and after the operation of LASIK. 91.57% of the eyes after the operation reached the vision >or= 0.8, which says a significant improvement for binocular vision after the operation (P < 0.05). There was a significant difference on diopter between the pre-operation and post-operation (P < 0.05). As for anisometropia, there was no significant difference between simultaneous binocular visions (P = 0.431), but there was of great significance among combined, short and long distance stereopsis visions (P = 0.000). Binocular vision deteriorated as anisometropia increased (P < 0.05). The short distance stereopsis visions of LASIK-treated myopic anisometropia were better than that of glasses-corrected patients (P < 0.05). The operation of LASIK can improve the visual quality and resume the binocular vision. LASIK can correct anisometropia and its therapeutic efficacy deserves to confirm.
Laser Vision Correction with Q Factor Modification for Keratoconus Management.
Pahuja, Natasha Kishore; Shetty, Rohit; Sinha Roy, Abhijit; Thakkar, Maithil Mukesh; Jayadev, Chaitra; Nuijts, Rudy Mma; Nagaraja, Harsha
2017-04-01
To evaluate the outcomes of corneal laser ablation with Q factor modification for vision correction in patients with progressive keratoconus. In this prospective study, 50 eyes of 50 patients were divided into two groups based on Q factor (>-1 in Group I and ≤-1 in Group II). All patients underwent a detailed ophthalmic examination including uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), subjective acceptance and corneal topography using the Pentacam. The topolyzer was used to measure the corneal asphericity (Q). Ablation was performed based on the preoperative Q values and thinnest pachymetry to obtain a target of near normal Q. This was followed by corneal collagen crosslinking to stabilize the progression. Statistically significant improvement (p ≤ 0.05) was noticed in refractive, topographic, and Q values posttreatment in both groups. The improvement in higher-order aberrations and total aberrations were statistically significant in both groups; however, the spherical aberration showed statistically significant improvement only in Group II. Ablation based on the preoperative Q and pachymetry for a near normal postoperative Q value appears to be an effective method to improve the visual acuity and quality in patients with keratoconus.
Modified Monovision With Spherical Aberration to Improve Presbyopic Through-Focus Visual Performance
Zheleznyak, Len; Sabesan, Ramkumar; Oh, Je-Sun; MacRae, Scott; Yoon, Geunyoung
2013-01-01
Purpose. To investigate the impact on visual performance of modifying monovision with monocularly induced spherical aberration (SA) to increase depth of focus (DoF), thereby enhancing binocular through-focus visual performance. Methods. A binocular adaptive optics (AO) vision simulator was used to correct both eyes' native aberrations and induce traditional (TMV) and modified (MMV) monovision corrections. TMV was simulated with 1.5 diopters (D) of anisometropia (dominant eye at distance, nondominant eye at near). Zernike primary SA was induced in the nondominant eye in MMV. A total of four MMV conditions were tested with various amounts of SA (±0.2 and ±0.4 μm) and fixed anisometropia (1.5 D). Monocular and binocular visual acuity (VA) and contrast sensitivity (CS) at 10 cyc/deg and binocular summation were measured through-focus in three cyclopledged subjects with 4-mm pupils. Results. MMV with positive SA had a larger benefit for intermediate distances (1.5 lines at 1.0 D) than with negative SA, compared with TMV. Negative SA had a stronger benefit in VA at near. DoF of all MMV conditions was 3.5 ± 0.5 D (mean) as compared with TMV (2.7 ± 0.3 D). Through-focus CS at 10 cyc/deg was significantly reduced with MMV as compared to TMV only at intermediate object distances, however was unaffected at distance. Binocular summation was absent at all object distances except 0.5 D, where it improved in MMV by 19% over TMV. Conclusions. Modified monovision with SA improves through-focus VA and DoF as compared with traditional monovision. Binocular summation also increased as interocular similarity of image quality increased due to extended monocular DoF. PMID:23557742
Influence of Near-Segment Positioning in a Rotationally Asymmetric Multifocal Intraocular Lens.
Song, In Seok; Yoon, Sam Young; Kim, Jae Yong; Kim, Myoung Joon; Tchah, Hungwon
2016-04-01
To compare visual performance and higher order aberrations (HOAs) based on the position of the near segment in eyes with rotationally asymmetric multifocal intraocular lenses (IOLs). Asymmetric multifocal IOLs (Lentis Mplus LS-313; Oculentis Optikgeräte GmbH, Wetzlar, Germany) were implanted with the near segment positioned either inferiorly, superiorly, or temporally. Uncorrected distance (UDVA), intermediate (UIVA), and near (UNVA) visual acuity, corrected distance visual acuity (CDVA), and distance-corrected intermediate (DCIVA) and near (DCNVA) visual acuity, contrast sensitivity, HOAs, and subjective symptom questionnaires were compared at 1 month postoperatively. Forty-five eyes from 45 patients were evaluated (n = 25, 9, and 11 eyes in the inferior, superior, and temporal groups, respectively). No significant differences in UDVA, UIVA, UNVA, CDVA, DCIVA, or DCNVA were found between the three groups (P > .05). The temporal group showed the best results in UDVA, CDVA, and DCNVA, but the inferior group showed the best results in DCIVA and UNVA and the superior group showed the best results in UIVA. Contrast sensitivity and the subjective symptom questionnaire also did not demonstrate any significant differences (P > .05). Total HOA and spherical aberration did not demonstrate any statistically significant differences (P > .05), but vertical coma and horizontal coma demonstrated significant differences based on near segment position (P < .001). The position of the near segment in eyes with rotationally asymmetric multifocal IOLs demonstrates no significant effect on visual performance. Copyright 2016, SLACK Incorporated.
Hayashi, Ken; Manabe, Shin-Ichi; Hayashi, Hideyuki
2009-12-01
To compare visual acuity from far to near, contrast visual acuity, and acuity in the presence of glare (glare visual acuity) between an aspheric diffractive multifocal intraocular lens (IOL) with a low addition (add) power (+3.0 diopters) and a monofocal IOL. Hayashi Eye Hospital, Fukuoka, Japan. This prospective study comprised patients having implantation of an aspheric diffractive multifocal ReSTOR SN6AD1 IOL with a +3.0 D add (multifocal group) or a monofocal AcrySof IQ SN60WF IOL (monofocal group). Visual acuity from far to near distances, contrast acuity, and glare acuity were evaluated 3 months postoperatively. Each IOL group comprised 64 eyes of 32 patients. For monocular and binocular visual acuity, the mean uncorrected and distance-corrected intermediate acuity at 0.5 m and the near acuity at 0.3 m were significantly better in the multifocal group than in the monofocal group (P=.0035); distance and intermediate acuity at 0.7 m and 1.0 m were similar between the 2 groups. No significant differences were observed between groups in contrast acuity and glare acuity under photopic and mesopic conditions. Furthermore, no significant correlation was found between all-distance acuity and pupil diameter or between visual acuity and IOL decentration and tilt. The diffractive multifocal IOL with a low add power provided significantly better intermediate and near visual acuity than the monofocal IOL. Contrast sensitivity with and without glare was reduced with the multifocal IOL, and all-distance visual acuity was independent of pupil diameter and IOL displacement.
Visual Acuity and Over-refraction in Myopic Children Fitted with Soft Multifocal Contact Lenses.
Schulle, Krystal L; Berntsen, David A; Sinnott, Loraine T; Bickle, Katherine M; Gostovic, Anita T; Pierce, Gilbert E; Jones-Jordan, Lisa A; Mutti, Donald O; Walline, Jeffrey J
2018-04-01
Practitioners fitting contact lenses for myopia control frequently question whether a myopic child can achieve good vision with a high-add multifocal. We demonstrate that visual acuity is not different than spectacles with a commercially available, center-distance soft multifocal contact lens (MFCL) (Biofinity Multifocal "D"; +2.50 D add). To determine the spherical over-refraction (SOR) necessary to obtain best-corrected visual acuity (BCVA) when fitting myopic children with a center-distance soft MFCL. Children (n = 294) aged 7 to 11 years with myopia (spherical component) of -0.75 to -5.00 diopters (D) (inclusive) and 1.00 D cylinder or less (corneal plane) were fitted bilaterally with +2.50 D add Biofinity "D" MFCLs. The initial MFCL power was the spherical equivalent of a standardized subjective refraction, rounded to the nearest 0.25 D step (corneal plane). An SOR was performed monocularly (each eye) to achieve BCVA. Binocular, high-contrast logMAR acuity was measured with manifest spectacle correction and MFCLs with over-refraction. Photopic pupil size was measured with a pupilometer. The mean (±SD) age was 10.3 ± 1.2 years, and the mean (±SD) SOR needed to achieve BCVA was OD: -0.61 ± 0.24 D/OS: -0.58 ± 0.27 D. There was no difference in binocular high-contrast visual acuity (logMAR) between spectacles (-0.01 ± 0.06) and best-corrected MFCLs (-0.01 ± 0.07) (P = .59). The mean (±SD) photopic pupil size (5.4 ± 0.7 mm) was not correlated with best MFCL correction or the over-refraction magnitude (both P ≥ .09). Children achieved BCVA with +2.50 D add MFCLs that was not different than with spectacles. Children typically required an over-refraction of -0.50 to -0.75 D to achieve BCVA. With a careful over-refraction, these +2.50 D add MFCLs provide good distance acuity, making them viable candidates for myopia control.
Eissa, Sherif A
2017-03-01
To assess the outcomes of sulcus implantation of the Visian ® implantable collamer lens (ICL) to correct pseudophakic myopic anisometropic amblyopia with myopic shift and/or primary refractive overcorrection. Prospective case series enrolled 14 pseudophakic eyes of 14 patients, 5-9 years old, with history of cataract surgery and primary in the bag-intraocular lenses (IOL) implantation, followed by myopic shift and/or refractive overcorrection and anisometropic amblyopia of variable degrees. All cases had implantation of a piggyback ICL/toric ICL, to correct the myopia/myopic astigmatism. Preoperatively, we evaluated the uncorrected distance visual acuity (UCVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), intraocular pressure (IOP) and endothelial cell density (ECD). We assessed the position and vaulting of the ICLs on slit lamp examination and confirmed by Scheimpflug tomography. Postoperative follow-up was at 1st week and 1, 3, 6, 9, 12, 18 and 24 months. Uncorrected distance visual acuity improved in all cases, and CDVA improved in 11 amblyopic eyes (2-4 lines). There was no evidence of interlenticular opacification (ILO) throughout the 2-year follow-up. Two cases were complicated with early postoperative acute elevation of IOP and were controlled with topical beta-blockers. Postoperative acute anterior uveitis occurred in six eyes and controlled by topical steroids. Implantable collamer lens (ICL) vault was measured using Pentacam, with mean value of 470 ± 238 μm. Sulcus implantation of the secondary piggyback ICL to correct unilateral pseudophakic myopic refractive error in children was safe, efficient, predictable and well tolerated in management of anisometropic amblyopia in all eyes. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Predictive Formula for Refraction of Autologous Lenticule Implantation for Hyperopia Correction.
Li, Meng; Li, Meiyan; Sun, Ling; Ni, Katherine; Zhou, Xingtao
2017-12-01
To create a formula to predict refractive correction of autologous lenticule implantation for correction of hyperopia (with myopia in one eye and hyperopia in the contralateral eye). In this prospective study, 10 consecutive patients (20 eyes) who had myopia in one eye and hyperopia in the contralateral eye were included. The preoperative spherical equivalent was -3.31 ± 1.73 diopters (D) for the myopic eyes and +4.46 ± 1.97 D for the hyperopic eyes. For each patient, the myopic eye was treated with small incision lenticule extraction and the lenticule was subsequently implanted into the contralateral hyperopic eye. The average length of follow-up was 17 months. All of the operations were successful without complications. At the last visit, the efficacy index (postoperative uncorrected distance visual acuity/preoperative corrected distance visual acuity [CDVA]) of the hyperopic eyes was 0.94 ± 0.35 and the safety index (postoperative CDVA/preoperative CDVA) was 1.36 ± 0.38. No eyes lost any lines of visual acuity. Six of 10 (60%) of the implanted eyes were within ±1.00 D of the intended refractive target. A predictive formula was derived: Lenticule implantation achieved correction (D) (LAC) = 1.224 Lenticule refractive power (D) (LRP) - 0.063 (R 2 =0.92, P < .001). On corneal topography, there was a significant increase in the corneal anterior surface keratometry value postoperatively, whereas the posterior surface keratometry value remained stable (P > .05). Autologous lenticule implantation could provide a reliable method of correcting hyperopia. The refractive correction formula may require further verification and adjustment. [J Refract Surg. 2017;33(12):827-833.]. Copyright 2017, SLACK Incorporated.
Linz, K; Auffarth, G U; Kretz, F T A
2014-08-01
Residual refractive errors, especially high-grade astigmatism after penetrating keratoplasty, often lead to a significant loss of vision. If high anismetropia could not be corrected with glasses or contact lenses, different kinds of surgical procedures are available for visual rehabilitation (intraocular lens exchange, astigmatic keratotomy, Excimer laser treatment, intrastromal corneal ring segment implantation and additive intraocular lens implantation). Toric add-on IOLs are especially designed for sulcus implantation and correcting high astigmatism in pseudophakic eyes. All toric IOLs are individually manufactured according to subjective refraction and biometry. Depending on the underlying manufacturer high-grade astigmatism can be corrected with a cylindrical power up to + 30.0 D. A 74-year-old patient presented with endothelial decompensation and an uncorrected distance visual acuity (UDVA) of 1.0 logMAR for penetrating keratoplasty on the right eye due to a Fuchs endothelial dystrophy. Postoperatively, the uncorrected distance visual acuity improved to 0.8 logMAR, with pinhole correction to 0.5 logMAR. After removing the sutures a high and irregular corneal astigmatism of 21.0 D was found. The corrected distance visual acuity (CDVA) with a refraction of + 5.5 D sph, - 21.0 D cyl 90° was 0.24 logMAR. Therefore an individually manufactured toric additive intraocular lens of + 25.0 D cylindrical and - 18.0 D spherical power for sulcus implantation was chosen and implanted uneventfully. Eight months after surgery refractive astigmatism was reduced significantly to - 0.75 D with an UDVA of 0.08 logMAR and a CDVA of 0.02 logMAR. During the 8-months follow-up period the additive IOL remained centered and no IOL rotation could be observed. Toric add-on IOLs are a safe and successful method for reducing high astigmatism and anisometropia after penetrating keratoplasty. One of the main advantages is the reversibility of the procedure by an explantation of the IOL. Georg Thieme Verlag KG Stuttgart · New York.
Enhanced Monocular Visual Odometry Integrated with Laser Distance Meter for Astronaut Navigation
Wu, Kai; Di, Kaichang; Sun, Xun; Wan, Wenhui; Liu, Zhaoqin
2014-01-01
Visual odometry provides astronauts with accurate knowledge of their position and orientation. Wearable astronaut navigation systems should be simple and compact. Therefore, monocular vision methods are preferred over stereo vision systems, commonly used in mobile robots. However, the projective nature of monocular visual odometry causes a scale ambiguity problem. In this paper, we focus on the integration of a monocular camera with a laser distance meter to solve this problem. The most remarkable advantage of the system is its ability to recover a global trajectory for monocular image sequences by incorporating direct distance measurements. First, we propose a robust and easy-to-use extrinsic calibration method between camera and laser distance meter. Second, we present a navigation scheme that fuses distance measurements with monocular sequences to correct the scale drift. In particular, we explain in detail how to match the projection of the invisible laser pointer on other frames. Our proposed integration architecture is examined using a live dataset collected in a simulated lunar surface environment. The experimental results demonstrate the feasibility and effectiveness of the proposed method. PMID:24618780
Chan, Tommy C. Y.; Yu, Marco C. Y.; Ng, Alex; Wang, Zheng; Cheng, George P. M.; Jhanji, Vishal
2016-01-01
We prospectively compared visual and refractive outcomes in patients with high myopia and myopic astigmatism after small-incision lenticule extraction (SMILE) and photorefractive keratetctomy (PRK) with mitomycin C. Sixty-six eyes of 33 patients (mean age, 29.7 ± 5.6 years) were included (SMILE: 34 eyes, PRK 32 eyes). Preoperatively, no significant difference was noted in manifest spherical equivalent (p = 0.326), manifest sphere (p = 0.277), and manifest cylinder (p = 0.625) between both groups. At 1 month, there were significant differences in logMAR uncorrected distance visual acuity, efficacy index and manifest refraction spherical equivalent between SMILE and PRK (p ≤ 0.029). At 6 months, the logMAR corrected distance visual acuity (p = 0.594), logMAR uncorrected visual acuity (p = 0.452), efficacy index (p = 0.215) and safety index was (p = 0.537) was comparable between SMILE and PRK. Significant differences were observed in postoperative manifest spherical equivalent (p = 0.044) and manifest cylinder (p = 0.014) between both groups. At the end of 6 months, 100% of the eyes in SMILE group and 69% of the eyes in PRK group were within ±0.50 D of the attempted cylindrical correction. The postoperative difference vector, magnitude of error and absolute angle of error were significantly smaller after SMILE compared to PRK (p ≤ 0.040) implying a trend towards overcorrection of cylindrical correction following PRK. PMID:27601090
Multifocal Intraocular Lens Results in Correcting Presbyopia in Eyes After Radial Keratotomy.
Kim, Kyeong Hwan; Seok, Kyung-Won; Kim, Wan Soo
2017-11-01
To report results of multifocal intraocular lens (IOL) implantation in 2 patients with refractive error and presbyopia after previous radial keratotomy (RK). A refractive multifocal IOL with rotational asymmetry (LS313-MF30; Oculentis, Berlin, Germany) was implanted. The first patient was a 60-year-old man with myopia who underwent unilateral RK 20 years before. His uncorrected distance visual acuity (UDVA) was 20/400, and his distance corrected near vision was J9 in both eyes. Six months after bilateral surgery, his binocular UDVA and uncorrected near visual acuity (UNVA) improved to 20/20 and J1, respectively, although he experienced diurnal fluctuation. The second patient was a 55-year-old woman with hyperopia who underwent bilateral RK 18 years before. Uncorrected distance visual acuity was 20/25 in both eyes, but UNVA was between J9 and J10. Three months after unilateral surgery, UDVA and UNVA of the postsurgical eye improved to 20/20 and J1, respectively. Neither patient reported any significant photic phenomena, and both were satisfied with the results of treatment. The desirable clinical outcomes and levels of satisfaction expressed by these patients indicate that surgery using this particular multifocal IOL may benefit presbyopic patients with previous RK.
Gutfreund, Shay; Leon, Pia; Busin, Massimo
2017-07-01
To describe the surgical technique and report the outcomes of patients treated with microkeratome-assisted anterior lamellar keratoplasty (MALK) for the correction of high-degree postkeratoplasty astigmatism. Four eyes of 2 patients with extremely high (>10 D) and irregular [surface asymmetry index >1.0 D] post-penetrating keratoplasty astigmatism occurring after complete suture removal underwent MALK and were followed for at least 3 years after the procedure. In all cases, 250-µm lamellar keratectomy was performed, followed by 2 full-thickness incisions through the penetrating keratoplasty scar and the placement of an appropriately sized donor graft, which was secured with a double-running 10-0 nylon suture. All sutures were removed in all eyes within 1 year from surgery. Corrected distance visual acuity, refraction, corneal topography, and endothelial cell density were noted at each examination. At the last follow-up examination (3 years or longer after MALK), corrected distance visual acuity had improved to 20/20, refractive astigmatism had decreased to an average of 2.1 D (in all cases within 4.5 D), and the average surface asymmetry index had reduced from 2.27 to 0.56. MALK is an effective and safe technique for the correction of high-degree postkeratoplasty astigmatism.
Ziaei, Mohammed; Mearza, Ali A; Allamby, David
2015-08-01
To present the first reported series of patients undergoing myopic LASIK with the FEMTO LDV Crystal Line femtosecond laser and the WaveLight Allegretto Eye-Q excimer laser. We report the uncorrected and corrected distance visual acuity (UDVA and CDVA), refractive predictability, efficacy and safety of laser in situ keratomileusis (LASIK) performed with the above laser platforms. This prospective interventional case series study evaluated consecutive eyes with low to moderate myopic astigmatism that underwent LASIK with the FEMTO LDV Crystal Line femtosecond laser and the WaveLight Allegretto Eye-Q 400 Hz excimer laser. Visual and refractive changes as well as complications were evaluated after wavefront-optimized laser treatment. Four hundred and forty four patients (887 eyes) reached the 6-month time gate. Mean age at time of procedure was 31 years (range: 20-59). Mean pre-op spherical-equivalent (SE) was -3.44 diopters (D)±1.34D (range: -0.50 to -7.00) whilst the postoperative spherical equivalent decreased to -0.08±0.31D (range -2.25 to 1.00). At 6-month follow up, 96.9% of patients had monocular uncorrected distance visual acuity of 20/20 or better with 95.2% of patients within ±0.5D of intended refractive outcome. All patients achieved 20/20 binocular distance uncorrected visual acuity. No significant intra-operative or postoperative complications were encountered during the 6-month follow-up period. The combination of the above laser platforms provides safe, effective and predictable results in correcting compound myopic astigmatism with excellent visual outcomes. Copyright © 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Verdoorn, Cornelis
2017-01-01
To compare the visual performance and optical quality after Raindrop Near Vision Inlay implantation or monovision LASIK for the correction of presbyopia. In this retrospective case-series study, patients previously treated in the nondominant eye with monovision LASIK were compared with patients previously implanted with Raindrop Near Vision Inlay. The study enrolled 16 inlay and 15 monovision LASIK patients. Uncorrected near visual acuity, uncorrected distance visual acuity, binocular stereopsis, patient satisfaction, and patient task performance were assessed. Postoperatively, the mean spherical equivalent was -0.66 D (0.78 SD) for the inlay group and -1.03 D (0.56 SD) for the monovision LASIK group. Monocularly, at uncorrected near distances, 60% of inlay patients and 47% of monovision LASIK patients achieved ≥20/20. Monocularly, at uncorrected far distances, 75% of inlay patients and 40% of monovision LASIK patients achieved ≥20/32 vision. Binocularly, at near distances, 79% of inlay patients and 53% of monovision LASIK patients obtained ≥20/20 vision. All patients achieved ≥20/20 binocularly for distance. On average, inlay patients obtained 98 seconds of arc and monovision LASIK patients obtained 286 seconds of arc for stereopsis. Most (79%) of the inlay patients and 66% of monovision LASIK patients were satisfied with their near vision, while 86% of inlay patients and 67% of monovision LASIK patients were satisfied with their distance vision. Patients receiving corneal inlays demonstrated better near and distance visual acuities, binocular stereopsis, task performance, and satisfaction, when compared to patients treated with monovision LASIK.
LASIK flap buttonhole treated immediately by PRK with mitomycin C.
Kymionis, George D; Portaliou, Dimitra M; Karavitaki, Alexandra E; Krasia, Maria S; Kontadakis, Georgios A; Stratos, Aimilianos; Yoo, Sonia H
2010-03-01
To describe the visual outcomes of three patients who had LASIK flap buttonhole and were treated immediately with photorefractive keratectomy (PRK) and topical mitomycin C (MMC) 0.02%. Three patients underwent bilateral LASIK with the SCHWIND Carriazo-Pendula 90 microm head microkeratome. In all three cases, a buttonhole flap occurred in the left eye. The flap was repositioned and phototherapeutic keratectomy for 50 microm was used for epithelial removal while immediate PRK with MMC was performed to treat the buttonhole flap. Three months after the procedure, uncorrected distance visual acuity and corrected distance visual acuity were 20/20 with regular topographic findings. Using PRK with MCC immediately after the occurrence of the LASIK flap buttonhole may be an effective treatment.
Chayet, Arturo; Barragan Garza, Enrique
2013-11-01
To perform a feasibility study of the safety and efficacy of a corneal-contouring inlay with concurrent laser in situ keratomileusis (LASIK) to treat hyperopic presbyopia. Private clinic, Tijuana, Mexico. Prospective interventional case series. Hyperopic patients received LASIK in both eyes and a corneal inlay under the femtosecond laser flap in the nondominant eye. The inlay is designed to reshape the anterior corneal curvature, creating a near-center multifocal refractive effect. Main safety outcomes were retention of preoperative corrected distance and near visual acuities and reports of adverse events. Efficacy was determined through measurements of near, intermediate, and distance visual acuities and patient questionnaires on visual task ability and satisfaction. The study enrolled 16 patients. All eyes with an inlay achieved an uncorrected near visual acuity (UNVA) of 20/32 or better by the 1-week postoperative examination and at every visit thereafter. The mean monocular and binocular UNVA was 20/27 or better at all visits. The mean binocular uncorrected distance visual acuity improved significantly from 20/53 preoperatively to 20/19 postoperatively (P<10(-5)). One inlay was explanted during the study. At 1 year, all 14 patients analyzed were satisfied or very satisfied with their near, distance, and overall vision. The hydrogel corneal inlay with concurrent LASIK improved uncorrected near, intermediate, and distance visual acuity in hyperopic presbyopic patients with high patient satisfaction and visual task ability. This represents a new indication for this recently developed technology. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Garza, Enrique Barragan; Chayet, Arturo
2015-02-01
To study the safety and efficacy of implanting a hydrogel corneal inlay (Raindrop Near Vision Inlay) concurrently with performing laser in situ keratomileusis (LASIK) to treat myopic presbyopia and to compare the results with results of the same treatment in emmetropic and hyperopic patients. Two private clinics, Tijuana and Monterrey, Mexico. Prospective nonrandomized clinical trial. Bilateral myopic LASIK was performed and a corneal inlay was concurrently implanted in the nondominant eye under a flap created using a femtosecond laser. Primary safety outcomes were the retention of corrected distance (CDVA) and near (CNVA) visual acuities. Efficacy was evaluated on the basis of uncorrected near (UNVA), intermediate (UIVA), and distance (UDVA) visual acuities. A patient questionnaire was used to assess the preoperative and postoperative incidence of visual symptoms, the ability to perform common tasks with no correction, and patient satisfaction with vision. Thirty eyes were enrolled. At each postoperative visit, the mean CDVA and CNVA were within one half line of preoperative measurements and no eye lost 2 or more lines of CDVA. The mean binocular UDVA, UIVA, and UNVA were better than 20/25 Snellen at all postoperative visits. By 6 months, 93% of patients had a binocular Snellen acuity of 20/25 or better across all visual ranges. According to patient questionnaires, 1 year after surgery, visual symptoms were at preoperative levels, 98% of all visual tasks could be easily performed without correction, and 90% of patients were satisfied or very satisfied with their overall vision. A hydrogel corneal inlay with concurrent LASIK was safe and effective for treating myopic presbyopia. Drs. Garza and Chayet are consultants to and investigators for Revision Optics, Inc. Copyright © 2015. Published by Elsevier Inc.
Adib-Moghaddam, Soheil; Soleyman-Jahi, Saeed; Salmanian, Bahram; Omidvari, Amir-Houshang; Adili-Aghdam, Fatemeh; Noorizadeh, Farsad; Eslani, Medi
2016-11-01
To evaluate the long-term quantitative and qualitative optical outcomes of 1-step transepithelial photorefractive keratectomy (PRK) to correct myopia and astigmatism. Bina Eye Hospital, Tehran, Iran. Prospective interventional case series. Eyes with myopia with or without astigmatism were evaluated. One-step transepithelial PRK was performed with an aberration-free aspheric optimized profile and the Amaris 500 laser. Eighteen-month follow-up results for refraction, visual acuities, vector analysis, higher-order aberrations, contrast sensitivity, postoperative pain, and haze grade were assessed. The study enrolled 146 eyes (74 patients). At the end of follow-up, 93.84% of eyes had an uncorrected distance visual acuity of 20/20 or better and 97.94% of eyes were within ±0.5 diopter of the targeted spherical refraction. On vector analysis, the mean correction index value was close to 1 and the mean index of success and magnitude of error values were close to 0. The achieved correction vector was on an axis counterclockwise to the axis of the intended correction. Photopic and mesopic contrast sensitivities and ocular and corneal spherical, cylindrical, and corneal coma aberrations significantly improved (all P < .001). A slight amount of trefoil aberration was induced (P < .001, ocular aberration; P < .01, corneal aberration). No eye lost more than 1 line of corrected distance visual acuity. No eye had a haze grade of 2+ degrees or higher throughout the follow-up. Eighteen-month results indicate the efficacy and safety of transepithelial PRK to correct myopia and astigmatism. It improved refraction and quality of vision. None of the authors has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Initial resident refractive surgical experience: outcomes of PRK and LASIK for myopia.
Wagoner, Michael D; Wickard, Joseph C; Wandling, George R; Milder, Lisa C; Rauen, Matthew P; Kitzmann, Anna S; Sutphin, John E; Goins, Kenneth M
2011-03-01
To evaluate and compare the outcome of initial resident surgical experience with photorefractive keratectomy (PRK) and LASIK. Retrospective review of all cases performed with the VISX Star S4 platform (Abbott Medical Optics) between July 1, 2003 and June 30, 2007. Inclusion criteria were spherical equivalent of -0.50 to -10.00 diopters (D), refractive astigmatic error of ≤3.00 D, intention to provide full distance correction, and minimum 3-month postoperative follow-up after initial ablation or retreatment (if performed). A total of 153 cases performed by 20 different residents met the inclusion criteria; 38 eyes underwent PRK and 115 eyes had LASIK. After initial treatment, mean Snellen uncorrected distance visual acuity (UDVA) after PRK was 20/17.3 and after LASIK was 20/19.5. Photorefractive keratectomy was associated with a significantly better approximation between preoperative corrected distance visual acuity (CDVA) and postoperative UDVA (ΔlogMAR 0.009 vs 0.091; P=.004) and a greater percentage of eyes that achieved UDVA of 20/20 or better (94.7% vs 78.3%; P=.02) or 20/30 or better (100% vs 87.8%; P=.02). There was a higher prevalence of retreatment in eyes that underwent LASIK (7.0% vs 0%; P=.20). One (0.9%) eye lost 2 lines of CDVA after LASIK. Supervised refractive surgery residents can achieve excellent visual outcomes in patients operated during their initial refractive experience. Photorefractive keratectomy was associated with better visual outcome than LASIK. Copyright 2011, SLACK Incorporated.
The Safety and Predictability of Implanting Autologous Lenticule Obtained by SMILE for Hyperopia.
Sun, Ling; Yao, Peijun; Li, Meiyan; Shen, Yang; Zhao, Jing; Zhou, Xingtao
2015-06-01
To evaluate the safety, effectiveness, stability, and predictability of implanting autologous lenticules obtained from small incision lenticule extraction for the treatment of hyperopia. Five patients (10 eyes) with one myopic eye and one hyperopic eye were enrolled. The myopic eye was treated with small incision lenticule extraction; a lenticule was extracted and subsequently implanted in the hyperopic eye. Follow-up was at 1 day, 1, 3, 6, and 9 months, and 1 year postoperatively. Patients received a complete ophthalmologic examination at each visit, including uncorrected distance visual acuity, corrected distance visual acuity, anterior segment optical coherence tomography, and corneal topography. There were no complications in any eye during follow-up. Compared with preoperative levels, at the last follow-up visit the eyes with lenticule implantation showed mean spherical equivalent reduced by 5.53 diopters (residual spherical equivalent was +1.13 to -2.63 diopters), mean uncorrected distance visual acuity increased approximately two lines (approximately 20/63 to 20/40 Snellen), and corrected distance visual acuity in 4 (80%) eyes gained one line, 2 (40%) eyes gained two lines, and 1 (20%) eye gained more than two lines. There was no significant difference (P > .05) in spherical equivalent compared with 1 day postoperatively and the last follow-up visit. Corneal topography showed that the lenticule was uniform and located well; anterior segment optical coherence tomography images showed that the lenticule was transparent and the demarcation line was visible. Implanting an autologous lenticule obtained by small incision lenticule extraction for hyperopia might be safe, effective, and stable, but its predictability should be improved in the future. Copyright 2015, SLACK Incorporated.
A comparison of visual outcomes in three different types of monofocal intraocular lenses
Shetty, Vijay; Haldipurkar, Suhas S; Gore, Rujuta; Dhamankar, Rita; Paik, Anirban; Setia, Maninder Singh
2015-01-01
AIM To compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens). METHODS The present study is a cross-sectional analysis of secondary clinical data collected from 153 eyes (52 eyes in Matrix Aurium, 48 in AcrySof single piece, and 53 in AcrySof IQ group) undergoing cataract surgery (2011-2012). We compared near vision, distance vision, distance corrected near vision in these three types of lenses on day 15 (±3) post-surgery. RESULTS About 69% of the eyes in the Matrix Aurium group had good uncorrected distance vision post-surgery; the proportion was 48% and 57% in the AcrySof single piece and AcrySof IQ group (P=0.09). The proportion of eyes with good distance corrected near vision were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). Similarly, The proportion with good “both near and distance vision” were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). It was only the Matrix Aurium group which had significantly better both “distance and near vision” compared with the AcrySof IQ group (odds ratio: 5.87, 95% confidence intervals: 1.68 to 20.56). CONCLUSION Matrix Aurium monofocal lenses may be a good option for those patients who desire to have a good near as well as distance vision post-surgery. PMID:26682168
A comparison of visual outcomes in three different types of monofocal intraocular lenses.
Shetty, Vijay; Haldipurkar, Suhas S; Gore, Rujuta; Dhamankar, Rita; Paik, Anirban; Setia, Maninder Singh
2015-01-01
To compare the visual outcomes (distance and near) in patients opting for three different types of monofocal intraocular lens (IOL) (Matrix Aurium, AcrySof single piece, and AcrySof IQ lens). The present study is a cross-sectional analysis of secondary clinical data collected from 153 eyes (52 eyes in Matrix Aurium, 48 in AcrySof single piece, and 53 in AcrySof IQ group) undergoing cataract surgery (2011-2012). We compared near vision, distance vision, distance corrected near vision in these three types of lenses on day 15 (±3) post-surgery. About 69% of the eyes in the Matrix Aurium group had good uncorrected distance vision post-surgery; the proportion was 48% and 57% in the AcrySof single piece and AcrySof IQ group (P=0.09). The proportion of eyes with good distance corrected near vision were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). Similarly, The proportion with good "both near and distance vision" were 38%, 33%, and 15% in the Matrix Aurium, AcrySof single piece, and AcrySof IQ groups respectively (P=0.02). It was only the Matrix Aurium group which had significantly better both "distance and near vision" compared with the AcrySof IQ group (odds ratio: 5.87, 95% confidence intervals: 1.68 to 20.56). Matrix Aurium monofocal lenses may be a good option for those patients who desire to have a good near as well as distance vision post-surgery.
Objective Analysis of Performance of Activities of Daily Living in People With Central Field Loss.
Pardhan, Shahina; Latham, Keziah; Tabrett, Daryl; Timmis, Matthew A
2015-11-01
People with central visual field loss (CFL) adopt various strategies to complete activities of daily living (ADL). Using objective movement analysis, we compared how three ADLs were completed by people with CFL compared with age-matched, visually healthy individuals. Fourteen participants with CFL (age 81 ± 10 years) and 10 age-matched, visually healthy (age 75 ± 5 years) participated. Three ADLs were assessed: pick up food from a plate, pour liquid from a bottle, and insert a key in a lock. Participants with CFL completed each ADL habitually (as they would in their home). Data were compared with visually healthy participants who were asked to complete the tasks as they would normally, but under specified experimental conditions. Movement kinematics were compared using three-dimension motion analysis (Vicon). Visual functions (distance and near acuities, contrast sensitivity, visual fields) were recorded. All CFL participants were able to complete each ADL. However, participants with CFL demonstrated significantly (P < 0.05) longer overall movement times, shorter minimum viewing distance, and, for two of the three ADL tasks, needed more online corrections in the latter part of the movement. Results indicate that, despite the adoption of various habitual strategies, participants with CFL still do not perform common daily living tasks as efficiently as healthy subjects. Although indices suggesting feed-forward planning are similar, they made more movement corrections and increased time for the latter portion of the action, indicating a more cautious/uncertain approach. Various kinematic indices correlated significantly to visual function parameters including visual acuity and midperipheral visual field loss.
Distance- and near-visual impairment in rural Chinese adults in Kailu, Inner Mongolia.
Cheng, Fang; Shan, Li; Song, Wulian; Fan, Pan; Yuan, Huiping
2016-06-01
To investigate the prevalence and causes of distance-visual impairment and near-vision impairment in a rural Chinese population in Inner Mongolia. A population-based, cross-sectional study design was used to identify visual impairment in the Chinese aged 40 years and older living in Kailu County, Inner Mongolia. Low vision, blindness and near-visual impairment (NVI) were defined according to World Health Organization (WHO) criteria. The overall prevalence of blindness and visual impairment based on the presenting visual acuity (VA) was 2.2% (95% CI: 1.8-2.6) and 9.8% (95% CI: 8.9-10.6), respectively, and was adjusted to 0.9% (95% CI: 0.6-1.2) and 4.7% (95% CI: 4.1-5.3) using best-corrected visual acuity (BCVA), respectively. Taking the presenting VA into consideration, the leading cause of visual impairment and blindness was cataract (40.3%, 40.9%), followed by uncorrected refractive error (26.6%, 28.2%). According to the BCVA, the main cause of visual impairment and blindness was cataract (48.3%, 41.3%) followed by glaucoma (19.0%, 23.9%). Among the examined subjects, 80.3% had NVI, and 51.7% had presbyopia. Major barriers reported by NVI persons without near correction were lack of money to purchase prescription glasses and poor quality of the available ones (43.2%). Visual impairment is a serious public health problem, and the main causes leading to visual impairment are treatable and preventable in the rural Chinese population in Inner Mongolia. Presbyopia, together with the low rate of spectacles and lack of appropriate refractive and presbyopia spectacles, is highly prevalent in rural China. © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Toric Intraocular Lens for Astigmatism Correction in Cataract Patients.
Razmjoo, Hassan; Ghoreishi, Mohammad; Milasi, Azadeh Mohammadi; Peyman, Alireza; Jafarzadeh, Zahra; Mohammadinia, Mohadeseh; Kobra, Nasrollahi
2017-01-01
To assess the clinical consequences of AcrySof toric intraocular lens (IOL) and Hoya toric IOL implantation to correct preexisting corneal astigmatism in patients undergoing cataract surgery. In this study, we examined 55 eyes of 45 patients with at least 1.00 D corneal astigmatism who were scheduled for cataract surgery. After phacoemulsification, toric IOL was inserted and axis was aligned. We observed the patients, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), keratometry, manifest refraction, and IOL axis alignment 6 months after surgery. After 6 months, the UDVA was 0.17 ± 0.17 logMAR in the AcrySof group and 0.17 ± 0.18 logMar in the Hoya group. More than 78% of eyes in the AcrySof group and 80% of eyes in the Hoya toric IOL achieved a UDVA of 20/40 or better. In the AcrySof group, the mean preoperative corneal astigmatism was 2.73 ± 0.92 D. The mean postoperative refractive astigmatism was 0.84 ± 0.63 D. In the Hoya group, the preoperative corneal astigmatism was 2.58 ± 0.76 D and the postoperative refractive astigmatism was 0.87 ± 0.66 D ( P < 0.05). The mean AcrySof IOL axis rotation was 1.88° ± 3.05°. In the Hoya group, the mean axis rotation was 1.53° ± 3.66°. All changes in visual and refractive data before and after surgery were statistically significant ( P < 0.05). There was no significant difference between the two groups regarding refractive and visual outcome after surgery ( P > 0.05 for all). Implantation of AcrySof toric IOL and Hoya toric IOL was an effective way to correct preexisting corneal astigmatism in cataract surgery.
Chandrasekaran, Navasuja; Harlow, Sioban; Moroi, Sayoko; Musch, David; Peng, Qing; Karvonen-Gutierrez, Carrie
2017-02-01
Emerging evidence suggests that the prevalence rates of poor functioning and of disability are increasing among middle-aged individuals. Visual impairment is associated with poor functioning among older adults but little is known about the impact of vision on functioning during midlife. The objective of this study was to assess the impact of visual impairment on future physical functioning among middle-aged women. In this longitudinal study, the sample consisted of 483 women aged 42 to 56 years, from the Michigan site of the Study of Women's Health Across the Nation. At baseline, distance and near vision were measured using a Titmus vision screener. Visual impairment was defined as visual acuity worse than 20/40. Physical functioning was measured up to 10 years later using performance-based measures, including a 40-foot timed walk, timed stair climb and forward reach. Women with impaired distance vision at baseline had 2.81 centimeters less forward reach distance (95% confidence interval (CI): -4.19, -1.42) and 4.26s longer stair climb time (95% CI: 2.73, 5.79) at follow-up than women without impaired distance vision. Women with impaired near vision also had less forward reach distance (2.26 centimeters, 95% CI: -3.30, -1.21) than those without impaired near vision. Among middle-aged women, visual impairment is a marker of poor physical functioning. Routine eye testing and vision correction may help improve physical functioning among midlife individuals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Chandrasekaran, Navasuja; Harlow, Sioban; Moroi, Sayoko; Musch, David; Peng, Qing; Karvonen-Gutierrez, Carrie
2016-01-01
Objectives Emerging evidence suggests that the prevalence rates of poor functioning and of disability are increasing among middle-aged individuals. Visual impairment is associated with poor functioning among older adults but little is known about the impact of vision on functioning during midlife. The objective of this study was to assess the impact of visual impairment on future physical functioning among middle-aged women. Study design In this longitudinal study, the sample consisted of 483 women aged 42 to 56 years, from the Michigan site of the Study of Women's Health Across the Nation. Main Outcome Measures At baseline, distance and near vision were measured using a Titmus vision screener. Visual impairment was defined as visual acuity worse than 20/40. Physical functioning was measured up to 10 years later using performance-based measures, including a 40-foot timed walk, timed stair climb and forward reach. Results Women with impaired distance vision at baseline had 2.81 centimeters less forward reach distance (95% confidence interval (CI): −4.19,−1.42) and 4.26 seconds longer stair climb time (95% CI: 2.73, 5.79) at follow-up than women without impaired distance vision. Women with impaired near vision also had less forward reach distance (2.26 centimeters, 95% CI: −3.30,−1.21) than those without impaired near vision. Conclusion Among middle-aged women, visual impairment is a marker of poor physical functioning. Routine eye testing and vision correction may help improve physical functioning among midlife individuals. PMID:28041592
Rosman, Mohamad; Wong, Tien Y; Tay, Wan-Ting; Tong, Louis; Saw, Seang-Mei
2009-08-01
To describe the prevalence and the risk factors of undercorrected refractive error in an adult urban Malay population. This population-based, cross-sectional study was conducted in Singapore in 3280 Malay adults, aged 40 to 80 years. All individuals were examined at a centralized clinic and underwent standardized interviews and assessment of refractive errors and presenting and best corrected visual acuities. Distance presenting visual acuity was monocularly measured by using a logarithm of the minimum angle of resolution (logMAR) number chart at a distance of 4 m, with the participants wearing their "walk-in" optical corrections (spectacles or contact lenses), if any. Refraction was determined by subjective refraction by trained, certified study optometrists. Best corrected visual acuity was monocularly assessed and recorded in logMAR scores using the same test protocol as was used for presenting visual acuity. Undercorrected refractive error was defined as an improvement of at least 0.2 logMAR (2 lines equivalent) in the best corrected visual acuity compared with the presenting visual acuity in the better eye. The mean age of the subjects included in our study was 58 +/- 11 years, and 52% of the subjects were women. The prevalence rate of undercorrected refractive error among Singaporean Malay adults in our study (n = 3115) was 20.4% (age-standardized prevalence rate, 18.3%). More of the women had undercorrected refractive error than the men (21.8% vs. 18.8%, P = 0.04). Undercorrected refractive error was also more common in subjects older than 50 years than in subjects aged 40 to 49 years (22.6% vs. 14.3%, P < 0.001). Non-spectacle wearers were more likely to have undercorrected refractive errors than were spectacle wearers (24.4% vs. 14.4%, P < 0.001). Persons with primary school education or less were 1.89 times (P = 0.03) more likely to have undercorrected refractive errors than those with post-secondary school education or higher. In contrast, persons with a history of eye disease were 0.74 times (P = 0.003) less likely to have undercorrected refractive errors. The proportion of undercorrected refractive error among the Singaporean Malay adults with refractive errors was higher than that of the Singaporean Chinese adults with refractive errors. Undercorrected refractive error is a significant cause of correctable visual impairment among Singaporean Malay adults, affecting one in five persons.
Lundström, Mats; Barry, Peter; Henry, Ype; Rosen, Paul; Stenevi, Ulf
2013-05-01
To analyze the visual outcome after cataract surgery. Cataract surgery clinics in 15 European countries. Database study. Data were drawn from case series of cataract extractions reported to the European Registry of Quality Outcomes for Cataract and Refractive Surgery database. These data were entered into the database via the Web by surgeons or by transfer from existing national registries or electronic medical record systems. The database contains individual anonymous data on preoperative, intraoperative, and postoperative measurements. Data on 368,256 cataract extractions were available for analysis. The best visual outcome was achieved in age groups 40 to 74 years, and men showed a higher percentage of excellent vision (1.0 [20/20] or better) than women. A corrected distance visual acuity (CDVA) of 0.5 (20/40) or better and of 1.0 (20/20) or better was achieved in 94.3% and 61.3% of cases, respectively. Ocular comorbidity and postoperative complications were the strongest influences on the visual outcome; however, surgical complications and ocular changes requiring complex surgery also had a negative influence. Deterioration of visual acuity after the surgery (n= 6112 [1.7% of all cases]) was most common in patients with a good preoperative visual acuity. The visual outcomes of cataract surgery were excellent, with 61.3% of patients achieving a corrected distance visual acuity of 1.0 (20/20) or better. Age and sex influenced the visual outcomes, but the greatest influences were short-term postoperative complications, ocular comorbidity, surgical complications, and complex surgery. A weakness of the study could be that some of the data is self-reported to the registry. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Paz-Valiñas, L; de la Fuente-Cid, R; de Rojas-Silva, M V; López-Rodríguez, I; López-García, M
2015-04-01
To conduct a systematic review of the efficacy/effectiveness, safety and cost of Descemet's stripping automated endothelial keratoplasty (DSAEK) technique in patients with corneal endothelial failure. Comprehensive literature search conducted in the main biomedical databases from January-May 2012. Following a critical perusal of the total of 485 abstracts retrieved, 16 case series and one economic evaluation study were included. Corrected distance visual acuity and uncorrected distance visual acuity improved after treatment with DSAEK, attaining values of 0.6 to 0.8 and 0.5 respectively. The degree of post-DSAEK astigmatism was not significant with respect to baseline values. The main complications were graft dislocation-detachment (1.5-23%), primary failure (0-12%) and endothelial rejection (0.8-8.5%). In Fuchs' dystrophy and bullous keratopathy, data on the effectiveness of DSAEK indicate post-intervention improvement in uncorrected and corrected distance visual acuity. Astigmatism arising after DSAEK was not significant. The most significant post-DSAEK complications are linked to the viability of the graft, with the most frequent complications being dislocation-detachment and, to a lesser extent, endothelial rejection. The studies that assess DSAEK are case series, and for the most part retrospective. The quality of this type of studies is both low and limited. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.
Bhandari, Vipul; Rao, Chandan Latha; Ganesh, Sri; Brar, Sheetal
2015-01-01
To evaluate the efficacy of conjunctival autograft after the pterygium excision with fibrin adhesive using conjunctiva over the pterygium. This prospective study included 25 eyes of 25 patients with a mean age of 40±10 years, who underwent the pterygium excision with conjunctival autograft derived from the body of the pterygium and attached using fibrin glue. The mean follow-up period was 6 months. On all postoperative visits, changes in uncorrected visual acuity, corrected distance visual acuity, astigmatism, complications, and the evidence of recurrence were recorded. At the end of mean follow-up, uncorrected visual acuity and corrected distance visual acuity improved by one or two lines in all eyes treated. Mean astigmatism reduced significantly from a preoperative value from 2.308D to 1.248D postoperatively (P<0.026). Minor postoperative complications such as congestion, chemosis, and subconjunctival hemorrhage were seen, which resolved with time. No major sight-threatening or graft-related complications were detected. There was no evidence of recurrence during a follow-up period of 6 months. Self-conjunctival autograft following the pterygium excision appears to be a feasible, safe, and effective alternative method for management of pterygium. It also preserves the superior conjunctiva for future surgeries. However, longer follow-up is required to study the long-term outcomes, especially the incidence of recurrence.
Shabbott, Britne A; Sainburg, Robert L
2010-05-01
Visuomotor adaptation is mediated by errors between intended and sensory-detected arm positions. However, it is not clear whether visual-based errors that are shown during the course of motion lead to qualitatively different or more efficient adaptation than errors shown after movement. For instance, continuous visual feedback mediates online error corrections, which may facilitate or inhibit the adaptation process. We addressed this question by manipulating the timing of visual error information and task instructions during a visuomotor adaptation task. Subjects were exposed to a visuomotor rotation, during which they received continuous visual feedback (CF) of hand position with instructions to correct or not correct online errors, or knowledge-of-results (KR), provided as a static hand-path at the end of each trial. Our results showed that all groups improved performance with practice, and that online error corrections were inconsequential to the adaptation process. However, in contrast to the CF groups, the KR group showed relatively small reductions in mean error with practice, increased inter-trial variability during rotation exposure, and more limited generalization across target distances and workspace. Further, although the KR group showed improved performance with practice, after-effects were minimal when the rotation was removed. These findings suggest that simultaneous visual and proprioceptive information is critical in altering neural representations of visuomotor maps, although delayed error information may elicit compensatory strategies to offset perturbations.
Visual and IOP outcomes after PRK in pigment dispersion syndrome.
Bower, Kraig S; Sia, Rose K; Ryan, Denise S; Mines, Michael J; Stutzman, Richard D; Kuzmowych, Chrystyna P; Eaddy, Jennifer B; Coe, Charles D; Wroblewski, Keith J
2011-09-01
To report the results of photorefractive keratectomy (PRK) in patients with pigment dispersion syndrome. The pre- and postoperative records of patients with pigment dispersion syndrome who underwent PRK between January 2002 and March 2009 were reviewed. Data for analysis included gender, age, ablation depth, surgical complications, manifest refraction spherical equivalent, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), intraocular pressure (IOP), central corneal thickness (CCT), cup-to-disc (c/d) ratio, and postoperative complications. Thirty-seven eyes of 19 patients (17 men and 2 women) with a mean age of 37.5 ± 6.9 years were included for review. At final follow-up, mean 404.1±119.5 days postoperative, UDVA was 20/15 or better in 67.6%, 20/20 or better in 91.9%, and 20/25 or better in 100% of eyes; 94.6% of eyes were within 0.50 diopters (D) and 100% were within 1.00 D of emmetropia. Corrected distance visual acuity was unchanged from preoperative in 73% and improved by one line in 27% of eyes. No eye lost 1 or more lines of CDVA. When corrected for change in CCT and curvature, mean postoperative IOP was elevated from baseline (16.7 ± 3.8 mmHg) at 1 month (18.1 ± 4.9 mmHg, P =.044) but unchanged at any other time postoperatively. Two (11%) of 19 patients were steroid responders, requiring a single topical agent until completing the course of steroids. No significant change was noted in mean c/d ratio from baseline (0.35±0.12) to final postoperative (0.35 ± 0.13, P = .99). Although PRK in patients with pigment dispersion syndrome resulted in excellent UDVA, retention of CDVA, and low incidence of adverse effects 1 to 2 years after surgery, long-term safety and efficacy outcomes of PRK in this cohort remain speculative
Reproducibility of visual acuity assessment in normal and low visual acuity.
Becker, Ralph; Teichler, Gunnar; Gräf, Michael
2007-01-01
To assess the reproducibility of measurements of visual acuity in both the upper and lower range of visual acuity. The retroilluminated ETDRS 1 and ETDRS 2 charts (Precision Vision) were used for measurement of visual acuity. Both charts use the same letters. The sequence of the charts followed a pseudorandomized protocol. The examination distance was 4.0 m. When the visual acuity was below 0.16 or 0.03, then the examination distance was reduced to 1 m or 0.4 m, respectively, using an appropriate near correction. Visual acuity measurements obtained during the same session with both charts were compared. A total of 100 patients (age 8-90 years; median 60.5) with various eye disorders, including 39 with amblyopia due to strabismus, were tested in addition to 13 healthy volunteers (age 18-33 years; median 24). At least 3 out of 5 optotypes per line had to be correctly identified to pass this line. Wrong answers were monitored. The interpolated logMAR score was calculated. In the patients, the eye with the lower visual acuity was assessed, and for the healthy subjects the right eye. Differences between ETDRS 1 and ETDRS 2-acuity were compared. The mean logMAR values for ETDRS 1 and ETDRS 2 were -0.17 and -0.14 in the healthy eyes and 0.55 and 0.57 in the entire group. The absolute difference between ETDRS 1 and ETDRS 2 was (mean +/- standard deviation) 0.051 +/- 0.04 for the healthy eyes and 0.063 +/- 0.05 in the entire group. In the acuity range below 0.1 (logMAR > 1.0), the absolute difference (mean +/- standard deviation) between ETDRS 1 and ETDRS 2 of 0.072 +/- 0.04 did not significantly exceed the mean absolute difference in healthy eyes (p = 0.17). Regression analysis (|ETDRS 1 - ETDRS 2| vs. ETDRS 1) showed a slight increase of the difference between the two values with lower visual acuity (p = 0.0505; r = 0.18). Assuming correct measurement, the reproducibilty of visual acuity measurements in the lower acuity range is not significantly worse than in normals.
Visual efficiency among teenaged athletes and non-athletes
Omar, Rokiah; Kuan, Yau Meng; Zuhairi, Nurul Atikah; Manan, Faudziah Abd; Knight, Victor Feizal
2017-01-01
AIM To compare visual efficiency, specifically accom-modation, vergence, and oculomotor functions among athletes and non-athletes. METHODS A cross-sectional study on sports vision screening was used to evaluate the visual skills of 214 elementary students (107 athletes, 107 non-athletes), aged between 13 and 16y. The visual screening assessed visual parameters such as ocular motor alignment, accommodation, and vergence functions. RESULTS Mean visual parameters were compared between age-group matched athletes (mean age 14.82±0.98y) and non-athletes (mean age 15.00±1.04y). The refractive errors of all participants were corrected to maximal attainable best corrected visual acuity of logMAR 0.0. Accommodation function assessment evaluated amplitude of accommodation and accommodation facility. Vergence functions measured the near point of convergence, vergence facility, and distance fusional vergence at break and recovery point. Ocular motor alignment was not statistically significant between both groups. Athletes had a statistically significant amplitude of accommodation for both the right eye (t=2.30, P=0.02) and the left eye (t=1.99, P=0.05). Conversely, non-athletes had better accommodation facility (t=-2.54, P=0.01) and near point of convergence (t=4.39, P<0.001) when compared to athletes. Vergence facility was found to be better among athletes (t=2.47, P=0.01). Nevertheless, non-athletes were significantly better for both distance negative and positive fusional vergence. CONCLUSION Although the findings are still inconclusive as to whether athletes had superior visual skills as compared to non-athletes, it remains important to identify and elucidate the key visual skills needed by athletes in order for them to achieve higher performance in their sports. PMID:28944208
Ntodie, Michael; Abu, Sampson L; Kyei, Samuel; Abokyi, Samuel; Abu, Emmanuel K
2017-06-01
To determine the near vision spectacle coverage and barriers to obtaining near vision correction among adults aged 35 years and older in the Cape Coast Metropolis of Ghana. A population-based cross-sectional study design was adopted and 500 out of 576 participants aged 35 years and older were examined from 12 randomly selected clusters in Cape Coast, Ghana. All participants underwent a comprehensive eye examination which included: distance and near visual acuities measurements and external and internal ocular health assessments. Distance and near refractions were performed using subjective refraction technique. Information on participants' demographics, near vision correction status, near visual needs and barriers to acquiring near vision correction were obtained through a questionnaire administered as part of the study. The mean age of participants was 52.3±10.3 years of whom 280 (56%) were females and 220 (44%) were males. The near vision spectacle coverage was 25%, 33% "met need" for near vision correction in the presbyopic population, and 64% unmet need in the entire study population. After controlling for other variables, age (5 th and 6 th decades) and educational level were associated with "met need" for near vision correction (OR=2.7 (1.55-4.68), p =0.00, and OR=2.36 (1.18-4.72), p=0.02 respectively). Among those who needed but did not have near vision correction, 64 (26%) did not feel the need for correction, 55 (22%) stated that they were unaware of available interventions, and 53 (21%) found the cost of near vision correction prohibitive. There was a low near vision spectacle coverage in this population which suggests the need for strategies on health education and promotion to address the lack of awareness of spectacle need and cost of services.
The Visual Effects of Intraocular Colored Filters
Hammond, Billy R.
2012-01-01
Modern life is associated with a myriad of visual problems, most notably refractive conditions such as myopia. Human ingenuity has addressed such problems using strategies such as spectacle lenses or surgical correction. There are other visual problems, however, that have been present throughout our evolutionary history and are not as easily solved by simply correcting refractive error. These problems include issues like glare disability and discomfort arising from intraocular scatter, photostress with the associated transient loss in vision that arises from short intense light exposures, or the ability to see objects in the distance through a veil of atmospheric haze. One likely biological solution to these more long-standing problems has been the use of colored intraocular filters. Many species, especially diurnal, incorporate chromophores from numerous sources (e.g., often plant pigments called carotenoids) into ocular tissues to improve visual performance outdoors. This review summarizes information on the utility of such filters focusing on chromatic filtering by humans. PMID:24278692
Persistent pseudomyopia following a whiplash injury in a previously emmetropic woman.
Hughes, Fintan E; Treacy, Maxwell P; Duignan, Emma S; Mullaney, Paul B
2017-12-01
Accommodative spasm, which manifests as ciliary muscle spasm, convergent strabismus or miosis, is a recognised consequence of head trauma. In whiplash cases, cervical spine hyperextension poses a risk of contra-coup injury and brainstem trauma, and is known to affect the visual system. However, to date, no cases of accommodative spasm due to whiplash injury have been reported. We present the case of a 34-year-old female who developed sudden onset blurred distance vision after a rear impact car crash, having previously been emmetropic. Her unaided distance visual acuity was 20/70 in the right eye and 20/20 in the left. Best-corrected visual acuity in the right eye was 20/20 with a correction that progressed from -1.75 to -3.50 DS over the 12 months following the accident.This patient's sudden unilateral myopia, with unilaterally increased amplitude of accommodation suggests pseudomyopia due to accommodative spasm. Magnetic resonance imaging showed no evidence of injury to her brain stem, frontal lobes or oculomotor nerve. The patient is now well adjusted with a -3.50DS corrective lens for the right eye. The accommodation reflex is susceptible to injury at the occipital lobe, frontal eye fields, Edinger-Westphal nuclei and oculomotor nerves. As such it should be examined in patients who present with visual disturbances following whiplash injury.It is important that such cases are identified at presentation, as early intervention can improve outcomes in accommodative spasm and reduce the long term psychological effects often associated with whiplash injuries.
Yuzawa, Mitsuko; Ishibashi, Tatsuro; Honda, Yoshihito; Kubota, Nobue
2010-09-01
To resolve the problems of visual acuity assessment in grading the vision of the physically handicapped as proposed by the Subcommittee for Promoting the Realization of a Cohesive Society with the Visually Disabled, Science Council of Japan, a method suitable for assessing visual disturbances, and the relationship between the degree of visual disturbances and the degree of difficulty in activities of daily life are clarified. 151 persons with age-related macular degeneration were studied. Examination methods for measuring visual acuity and reading performance were studied, and interviews using the daily living task dependent on vision (DLTV) questionnaire were performed. The correlations between total DLTV score and each examination method were analyzed. The median total DLTV score for each grade of visual acuity of the better eye was calculated. Spearman's correlation coefficient between distance corrected visual acuity of the better eye and total DLTV score was 0.76. Median DLTV scores for visual acuities (better eye) of 0.2, 0.3, 0.4, 0.5 were 65, 73.5, 62, 79 respectively. Visual acuity can be assessed by measuring distant corrected visual acuity of the better eye and setting the upper limit of visual disturbance at either 0.3 or 0.4.
Xi, Lei; Zhang, Chen; He, Yanling
2018-05-09
To evaluate the refractive and visual outcomes of Transepithelial photorefractive keratectomy (TransPRK) in the treatment of low to moderate myopic astigmatism. This retrospective study enrolled a total of 47 eyes that had undergone Transepithelial photorefractive keratectomy. Preoperative cylinder diopters ranged from - 0.75D to - 2.25D (mean - 1.11 ± 0.40D), and the sphere was between - 1.50D to - 5.75D. Visual outcomes and vector analysis of astigmatism that included error ratio (ER), correction ratio (CR), error of magnitude (EM) and error of angle (EA) were evaluated. At 6 months after TransPRK, all eyes had an uncorrected distance visual acuity of 20/20 or better, no eyes lost ≥2 lines of corrected distant visual acuity (CDVA), and 93.6% had residual refractive cylinder within ±0.50D of intended correction. On vector analysis, the mean correction ratio for refractive cylinder was 1.03 ± 0.30. The mean error magnitude was - 0.04 ± 0.36. The mean error of angle was 0.44° ± 7.42°and 80.9% of eyes had axis shift within ±10°. The absolute astigmatic error of magnitude was statistically significantly correlated with the intended cylinder correction (r = 0.48, P < 0.01). TransPRK showed safe, effective and predictable results in the correction of low to moderate astigmatism and myopia.
Kuang, T-M; Tsai, S-Y; Liu, C J-L; Ko, Y-C; Lee, S-M; Chou, P
2016-01-01
Purpose To report the 7-year incidence of uncorrected refractive error in a metropolitan Chinese elderly population. Methods The Shihpai Eye Study 2006 included 460/824 (55.8%) subjects (age range 72–94 years old) of 1361 participants in the 1999 baseline survey for a follow-up eye examination. Visual acuity was assessed using a Snellen chart, uncorrected refractive error was defined as presenting visual acuity (naked eye if without spectacles and with distance spectacles if worn) in the better eye of <6/12 that improved to no impairment (≥6/12) after refractive correction. Results The 7-year incidence of uncorrected refractive error was 10.5% (95% confidence interval (CI): 7.6–13.4%). 92.7% of participants with uncorrection and 77.8% with undercorrection were able to improve at least two lines of visual acuity by refractive correction. In multivariate analysis controlling for covariates, uncorrected refractive error was significantly related to myopia (relative risk (RR): 3.15; 95% CI: 1.31–7.58) and living alone (RR: 2.94; 95% CI 1.14–7.53), whereas distance spectacles worn during examination was protective (RR: 0.35; 95% CI: 0.14–0.88). Conclusion Our study indicated that the incidence of uncorrected refractive error was high (10.5%) in this elderly Chinese population. Living alone and myopia are predisposing factors, whereas wearing distance spectacles at examination is protective. PMID:26795416
Spadea, Leopoldo; Paroli, Marino
2012-01-01
The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (-6.11 D ± 2.48, range -2.50 to -9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. After a mean 15 ± 6.5 (range 6-24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1-10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was -0.79 ± 2.09 (range +1 to -3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8-8.9) D. All the corneas remained clear (haze < 1). The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus.
An angle-supported foldable phakic intraocular lens for correction of myopia: A five-year follow-up.
Alió, J L; Plaza-Puche, A B; Cavas, F; Yébana Rubio, P; Sala, E
2017-01-01
To evaluate the efficacy and safety of an angle-supported foldable phakic intraocular lens (pIOL) for the correction of moderate to high myopia after 5 years follow-up. Prospective and retrospective, observational, longitudinal, non-randomised consecutive series of cases conducted on a total of 100 eyes of 67 patients with moderate to high myopia implanted with an Acrysof Cachet pIOL (Alcon Laboratories Inc.) with the aim of minimising the refractive error. The ages ranged between 18 to 60years. Uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity (CDVA), endothelial cells density, pIOL position, intraocular pressure, and complications were recorded preoperatively and during the 5 year follow-up. Five years after implantation, the mean manifest spherical equivalent refraction reduced significantly from -11.62±3.35 dioptres (D) to -0.33±0.85D. UDVA was 20/20 or better in 5 of 25 cases (20%), and 20/40 or better in 22 cases (88%). CDVA was 20/20 or better in 17 cases (68%), and 20/32 or better in 23 cases (92%) of eyes. The residual refractive error was within ±0.50D of emmetropia in 12 cases (48%), and within ±1.00D in 19 cases (76%). Mean endothelial cell loss at 5 years was 11.8% central, and 13.7% peripheral. Mean endothelium-pIOL distance was 2.11±0.18mm, and mean pIOL-crystalline distance was 0.88±0.20mm. This angle supported pIOL provided a favourable refractive correction and predictability, as well as acceptable safety in patients with moderate to high myopia. Although endothelial cell density decreased over 5years, the results are within the range reported in previous studies with other pIOLs. Copyright © 2016 Sociedad Española de Oftalmología. Publicado por Elsevier España, S.L.U. All rights reserved.
A guide to performing basic manifest refractometry.
Garber, N
2000-01-01
Refractometry provides the ophthalmologist with the prescription that has the most plus power with the best vision. This eliminates the need for the patient accommodating to achieve clear vision at distance. Flowcharts, of the refractometry process, help the refractionist use standard procedures to accurately arrive at the correct baseline prescription for the patient's refractive state. By using the patient's history of subjective complaints, past refractive corrections, and present visual needs, the ophthalmologist then can prescribe the final prescription.
Marmamula, Srinivas; Madala, Sreenivas R; Rao, Gullapalli N
2012-03-01
To investigate the prevalence of uncorrected refractive errors, presbyopia and spectacle coverage in subjects aged 40 years or more using a novel Rapid Assessment of Visual Impairment (RAVI) methodology. A population-based cross-sectional study was conducted using cluster random sampling to enumerate 1700 subjects from 34 clusters predominantly inhabited by marine fishing communities in the Prakasam district of Andhra Pradesh, India. Unaided, aided and pinhole visual acuity (VA) was assessed using a Snellen chart at a distance of 6 m. Near vision was assessed using an N notation chart. Uncorrected refractive error was defined as presenting VA < 6/18 and improving to ≥6/18 with pinhole. Uncorrected presbyopia was defined as binocular near vision worse than N8 in subjects with binocular distance VA ≥ 6/18. 1560 subjects (response rate - 92%) were available for examination. Of these, 54.6% were female and 10.1% were ≥70 years of age. Refractive error was present in 250 individuals. It was uncorrected in 179 (unmet need) and corrected in 71 (met need) individuals. Among 1094 individuals with no distance visual impairment, presbyopia was present in 494 individuals. It was uncorrected in 439 (unmet need) and corrected in 55 individuals (met need). Spectacle coverage was 28.4% for refractive errors and 11.1% for presbyopia. There is a high unmet need for uncorrected refractive errors and presbyopia among marine fishing communities in the Prakasam district of South India. The data from this study can now be used as a baseline prior to the commencement of eye care services in this region. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.
Lazaridis, Apostolos; Reinstein, Dan Z; Archer, Timothy J; Schulze, Stephan; Sekundo, Walter
2016-11-01
To design a technique for intrastromal transplantation of stromal lenticules with specific refractive power for correction of post-LASIK induced hyperopia and astigmatism. A 28-year-old patient was referred for consultation after complicated LASIK for moderate myopia and astigmatism. The refractive error of the right eye was severely overcorrected due to data entry error. Post-LASIK refraction showed high astigmatism (right eye: +6.50 -9.00 @ 84°) and corrected distance visual acuity (CDVA) of 20/32. The corneal thickness was 282 µm. A refractive lenticule transplantation was performed due to contact lens intolerance, poor visual acuity, and severe anisometropia. A toric and myopic lenticule, obtained from a donor using the femtosecond lenticule extraction technique, was implanted under the flap to reduce the refractive error, bring the refraction of the eye to the level correctable by phakic intraocular lens, and restore corneal volume. Six weeks postoperatively, the donor lenticule was spread smoothly in the interface with a minor temporal decentration in relation to pupil center. The refraction showed a reduction of astigmatism but a stronger myopization compared to preoperative calculations (right eye: -6.50 -4.00 @ 70°). At 3 months, the CDVA returned to the preoperative value of 20/32. One year postoperatively, corneal tomography showed no signs of ectasia and biomicroscopy revealed no signs of rejection. After implanting a toric myopic implantable collamer lens, the patient regained uncorrected distance visual acuity of 20/40 and full stereopsis. The refractive lenticule transplantation technique offers a solution for rare cases of post-LASIK hyperopia and high astigmatism while restoring the volume of thin corneas. Moreover, it is a reversible procedure with low probability of rejection. [J Refract Surg. 2016;32(11):780-786.]. Copyright 2016, SLACK Incorporated.
The Recovery of Optical Quality after Laser Vision Correction
Jung, Hyeong-Gi
2013-01-01
Purpose To evaluate the optical quality after laser in situ keratomileusis (LASIK) or serial photorefractive keratectomy (PRK) using a double-pass system and to follow the recovery of optical quality after laser vision correction. Methods This study measured the visual acuity, manifest refraction and optical quality before and one day, one week, one month, and three months after laser vision correction. Optical quality parameters including the modulation transfer function, Strehl ratio and intraocular scattering were evaluated with a double-pass system. Results This study included 51 eyes that underwent LASIK and 57 that underwent PRK. The optical quality three months post-surgery did not differ significantly between these laser vision correction techniques. Furthermore, the preoperative and postoperative optical quality did not differ significantly in either group. Optical quality recovered within one week after LASIK but took between one and three months to recover after PRK. The optical quality of patients in the PRK group seemed to recover slightly more slowly than their uncorrected distance visual acuity. Conclusions Optical quality recovers to the preoperative level after laser vision correction, so laser vision correction is efficacious for correcting myopia. The double-pass system is a useful tool for clinical assessment of optical quality. PMID:23908570
de Medeiros, André Lins; de Araújo Rolim, André Gustavo; Motta, Antonio Francisco Pimenta; Ventura, Bruna Vieira; Vilar, César; Chaves, Mário Augusto Pereira Dias; Carricondo, Pedro Carlos; Hida, Wilson Takashi
2017-01-01
Purpose The purpose of this study was to compare the visual outcomes and subjective visual quality between bilateral implantation of a diffractive trifocal intraocular lens, Alcon Acrysof IQ® PanOptix® TNFT00 (group A), and blended implantation of an extended depth of focus lens, J&J Tecnis Symfony® ZXR00 with a diffractive bifocal intraocular lens, J&J Vision Tecnis® ZMB00 (group B). Methods This prospective, nonrandomized, consecutive, comparative study included the assessment of 40 eyes in 20 patients implanted with multifocal intraocular lens. Exclusion criteria were existence of any corneal, retina, or optic nerve disease, previous eye surgery, illiteracy, previous refractive surgery, high axial myopia, expected postoperative corneal astigmatism of >1.00 cylindrical diopter (D), and intraoperative or postoperative complications. Binocular visual acuity was tested in all cases. Ophthalmological evaluation included the measurement of uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected near visual acuity (UNVA), and uncorrected intermediate visual acuity (UIVA), with the analysis of contrast sensitivity (CS), and visual defocus curve. Results Postoperative UDVA was 0.01 and −0.096 logMAR (p<0.01) in groups A and B, respectively; postoperative CDVA was −0.07 and −0.16 logMAR (p<0.01) in groups A and B, respectively; UIVA was 0.14 and 0.20 logMAR (p<0.01) in groups A and B, respectively; UNVA was −0.03 and 0.11 logMAR (p<0.01) in groups A and B, respectively. Under photopic conditions group B had better CS at low frequencies with and without glare. Conclusion Both groups promoted good quality of vision for long, intermediate, and short distances. Group B exhibited a better performance for very short distances and for intermediate and long distances ≥−1.50 D of vergence. Group A exhibited a better performance for UIVA at 60 cm and for UNVA at 40 cm. PMID:29138533
Shah, Shaheen P; Jadoon, Mohammad Z; Dineen, Brendan; Bourne, Rupert R A; Johnson, Gordon J; Gilbert, Clare E; Khan, Mohammad D
2008-01-01
To determine the prevalence of refractive error (RE) and spectacle wear and to explore the need for spectacle correction in adults (30 years or older) in Pakistan. Multi-stage, cluster random sampling national survey. Each subject had their medical history taken, visual acuity measured, and underwent autorefraction, biometry and fundus examination. Those that presented with visual acuity of less than 6/12 in either eye underwent more detailed examination, including corrected distance visual acuity measurement (autorefraction results placed in a trial lens frame). Myopia was defined as a spherical equivalent of worse than -0.5D, hypermetropia as greater than +0.5D, and astigmatism as greater than 0.75D. Spectacle need (i.e., those that improved from unaided VA with spectacle correction) was determined along with the spectacle coverage, defined as the proportion of need that was met (by the participant's own spectacles). The crude prevalence of myopia, hypermetropia and astigmatism was 36.5%, 27.1%, and 37%, respectively. The prevalence of spectacle wear in phakic participants was 4.0%, significantly lower than for those who were pseudo/aphakic (41.7%). Just over a quarter (25.8%) of spectacle wearers presenting with visual impairment (< 6/12) were able to improve their vision when retested with their autorefraction prescription. The overall spectacle coverage (6/12 cutoff) was 15.1%. This survey provides the first reliable national estimates. RE services are not covering the majority of the population in need and the provision of spectacle correction, as a highly cost effective treatment for visual impairment, needs addressing within the country's national eye care program.
Chan, Tommy C Y; Ng, Alex L K; Cheng, George P M; Wang, Zheng; Ye, Cong; Woo, Victor C P; Tham, Clement C Y; Jhanji, Vishal
2016-04-01
To compare astigmatic correction between femtosecond-assisted laser in situ keratomileusis (LASIK) and small-incision lenticule extraction (SMILE). A total of 111 patients were included in this prospective study. Fifty-seven eyes were treated with LASIK and 54 eyes were treated with SMILE for myopia with low to moderate (-0.25 to -4.0 D) astigmatism. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity and manifest refraction were measured preoperatively and at 1 and 3 months postoperatively. Visual and refractive outcomes were reported. Changes in refractive astigmatism were evaluated using vector analysis. Preoperative characteristics were similar between both groups. The UDVA at 1 and 3 months was better in the LASIK group compared with the SMILE group (p<0.009). Postoperative cylinder was higher in the SMILE group (p<0.001). Fewer eyes attained the attempted cylindrical correction in the SMILE group (p<0.029). Vector analysis showed no significant difference in target-induced astigmatism (p=0.091) and angle of error (p>0.596) between the two groups. Surgically induced astigmatism was significantly lower in the SMILE group (p<0.023), while the difference vector (p<0.001) and absolute angle of error (p<0.016) were significantly higher in the SMILE group. No significant difference was found in these parameters between 1 and 3 months in both groups (p>0.122). Our results showed that SMILE offered a less favourable astigmatic correction comparable to femtosecond-assisted LASIK in eyes with low to moderate myopic astigmatism. The alignment of treatment was more variable in SMILE, leading to a lower efficacy compared with LASIK by 3 months postoperatively. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Blindness and Visual Impairment in an Urban West African Population: The Tema Eye Survey
Budenz, Donald L.; Bandi, Jagadeesh R.; Barton, Keith; Nolan, Winifred; Herndon, Leon; Whiteside-de Vos, Julia; Hay-Smith, Graham; Kim, Hanna; Tielsch, James
2012-01-01
Objective To determine the prevalence, etiologies, and risk factors of blindness and visual impairment among persons age 40 years and older residing in an urban West African location. Design Population-based cross-sectional study. Participants Five thousand six hundred and three participants residing in Tema, Ghana. Methods Proportionate random cluster sampling was used to select participants age 40 and over living in the city of Tema. Presenting distance visual acuity was measured at 4 and 1 meters using a reduced Logarithm of the Minimum Angle of Resolution (logMAR) tumbling E chart and then with trial frame based on autorefraction. A screening examination was performed in the field on all participants. Complete clinical examination by an ophthalmologist was performed on participants with best corrected visual acuity < 20/40 or failure of any screening test. Main Outcome Measures Age- and gender-specific prevalence, causes, and risk factors for blindness (visual acuity in the better eye of < 20/400, World Health Organization definition) and visual impairment (visual acuity in the better eye of < 20/40). Results Six thousand eight hundred and six eligible participants were identified of which 5603 (82.3%) participated in the study. The mean age (±standard deviation) of participants was 52.7±10.9. The prevalence of visual impairment was 17.1% and blindness was 1.2%. After refraction and spectacle correction, the prevalence of visual impairment and blindness decreased to 6.7% and 0.75% respectively, suggesting that refractive error is the major correctable etiology of visual impairment and blindness in this population. Of 65 subjects having visual acuity < 20/400, 22 (34%) were correctable with refraction, 21 to the level of visual impairment, and one to normal. The remaining 43 (66%) had underlying pathology (19 cataract, 9 glaucoma, 3 non-glaucomatous optic neuropathy, 3 corneal opacities, 3 retinal disease, 5 undetermined) that prevented refractive correction. Increased age was a significant risk factor for blindness and visual impairment. Conclusions There is a high prevalence of blindness and visual impairment among those aged ≥40 years in Tema, Ghana, West Africa. Refractive error is a major cause of blindness and visual impairment in this population, followed by cataract, glaucoma, and corneal disease. PMID:22677425
Laitinen, Arja; Koskinen, Seppo; Härkänen, Tommi; Reunanen, Antti; Laatikainen, Leila; Aromaa, Arpo
2005-12-01
To estimate the prevalence rates of habitual visual acuity (VA) levels and visual impairment in Finland and to assess their correlation with self-reported visual function. Cross-sectional population-based study. Subjects were selected randomly from the Finnish population aged 30 years or older. Of 7979 eligible people, 7393 (93%) were interviewed, 6771 (85%) were examined, and 6663 (84%) had distance VA assessed. Participants underwent a home interview and a comprehensive examination including measuring binocular VA for distance and for near with the participants' current spectacles, if any. The level of VA for distance and for near with current spectacle correction. The self-reported capability to read newsprint and television text and the ability to move about without being restricted by reduced vision. The prevalence of good to moderate VA for distance (VA> or =0.5 [> or =20/40]) measured with current spectacles was 95.9%, and 87.4% had a VA level of 0.8 (20/25) or better. The prevalence of habitual visual impairment (VA< or =0.25 [< or =20/80]) was 1.6%, and 0.5% were blind (VA<0.1 [<20/200]). The prevalence of visual impairment increased significantly with age (P<0.001), especially in the age group of 65 to 74 years and upward. There was no gender difference in VA for distance, but decreased near vision (VA< or =0.25 [< or =20/80]) was significantly more common in men than in women (P<0.01). By applying the imputated numbers of visually impaired and blind participants to the Finnish population (approximately 3 million aged 30 years or older), there were approximately 65000 (2.1%) visually impaired and 17000 (0.6%) blind adult persons in the country in 2000. The correlation between self-reported visual ability and measured visual function was moderate but statistically significant (r = 0.27-0.40; P<0.0001). The proportion of people with reading difficulties or who were unable to read newsprint has decreased 7% during the last 2 decades. Functional visual impairment increased with age especially in the age group of 65 to 74 years and upward and was as prevalent in women as in men. The prevalence of people with reading difficulties has decreased considerably since 1980.
Sachdev, Gitansha Shreyas; Ramamurthy, Shreyas; Sharma, Umesh; Dandapani, Ramamurthy
2018-01-01
Purpose: The aim of this study was to analyze the objective and subjective visual outcomes of patients bilaterally implanted with the extended range of vision intraocular lens (EROV IOL), the Tecnis Symfony. Methods: This was a prospective interventional case series conducted at a tertiary eye care hospital in South India. The study included patients with bilateral implantation of EROV IOLs. The uncorrected and corrected visual acuity for distance, intermediate, and near vision was recorded at 6 weeks and 6 months’ postoperative visit. A subjective questionnaire was administered to assess spectacle independence, photic phenomenon, and overall satisfaction. All data were recorded using Microsoft Excel worksheet. The analyses were performed using SPSS for windows software. Results: Our study included fifty patients with bilateral implantation of EROV IOLs. The mean age was 59.84 ± 11.68 years. The mean uncorrected binocular distance, intermediate, and near visual acuity (in standard decimal equivalent) was 0.89,0.99 and 0.99 respectively, at 6 months’ postoperative visit. Ninety-six percent of the patients did not require spectacles for distance and 98% of the patients were free from spectacles for intermediate and near vision. 94% of our patients perceived no or minimal photic phenomena such as glare and halos. The mean subjective patient satisfaction score (out of 10) for distance, intermediate, and near was 9, 10, and 9, respectively. Conclusion: The EROV IOLs demonstrated high levels of spectacle independence for distance, intermediate, and near vision. The incidence of photic phenomena observed was minimal with a high level of patient satisfaction. PMID:29480252
Outcomes of photorefractive keratectomy in patients with atypical topography.
Movahedan, Hossein; Namvar, Ehsan; Farvardin, Mohsen
2017-11-01
Photorefractive keratectomy (PRK) is at risk of serious complications such as corneal ectasia, which can reduce corrected distance visual acuity. The rate of complications of PRK is higher in patients with atypical topography. To determine the outcomes of photorefractive keratectomy in patients with atypical topography. This cross-sectional study was done in 2015 in Shiraz in Iran. We included 85 eyes in this study. The samples were selected using a simple random sampling method. All patients were under evaluation for uncorrected distance visual acuity, corrected distance visual acuity, manifest refraction, corneal topography, central corneal thickness using pentacam, slit-lamp microscopy, and detailed fondus evaluation. The postoperative examination was done 1-7 years after surgery. Data were analyzed using IBM SPSS 21.0 version. To analyze the data, descriptive statistics (frequency, percentage, mean, and standard deviation), chi-square, and independent samples t-test were used. We studied 85 eyes. Among the patients, 23 (27.1%) were male and 62 (72.9%) were female. Mean age of the participants was 28.25±5.55 years. Mean postoperative refraction was - 0.37±0.55 diopters. Keratoconus or corneal ectasia was not reported in any patient in this study. There was no statistically significant difference between SI index before and after operation (p=0.736). Mean preoperative refraction was -3.84 ± 1.46 diopters in males and -4.20±1.96 diopters in females; thus there was not statistically significant difference (p = 0.435). PRK is a safe and efficient photorefractive surgery and is associated with low complication rate in patients with atypical topography.
Spadea, Leopoldo; Paroli, Marino
2012-01-01
Background The purpose of this paper is to report the results of using combined treatment of customized excimer laser-assisted photorefractive keratectomy (PRK) and prophylactic corneal collagen crosslinking (CXL) for residual refractive error in a group of patients who had previously undergone lamellar keratoplasty for keratoconus. Methods The study included 14 eyes from 14 patients who had originally been treated for keratoconus in one eye by excimer laser-assisted lamellar keratoplasty (ELLK), and subsequently presented with residual ametropia (−6.11 D ± 2.48, range −2.50 to −9.50). After a mean 40.1 ± 12.4 months since ELLK they underwent combined simultaneous corneal regularization treatment with topographically guided transepithelial excimer laser PRK (central corneal regularization) and corneal CXL induced by riboflavin-ultraviolet A. Results After a mean 15 ± 6.5 (range 6–24) months, all eyes gained at least one Snellen line of uncorrected distance visual acuity (range 1–10). No patient lost lines of corrected distance visual acuity, and four patients gained three lines of corrected distance visual acuity. Mean manifest refractive spherical equivalent was −0.79 ± 2.09 (range +1 to −3.0) D, and topographic keratometric astigmatism was 5.02 ± 2.93 (range 0.8–8.9) D. All the corneas remained clear (haze < 1). Conclusion The combination of customized PRK and corneal CXL provided safe and effective results in the management of corneal regularization for refractive purposes after ELLK for keratoconus. PMID:23152658
Stowasser, Annette; Buschbeck, Elke K
2014-11-01
A particularly unusual visual system exists in the visually guided aquatic predator, the Sunburst Diving Beetle, Thermonectus marmoratus (Coleoptera: Dytiscidae). The question arises: how does this peculiar visual system function? A series of experiments suggests that their principal eyes (E1 and E2) are highly specialized for hunting. These eyes are tubular and have relatively long focal lengths leading to high image magnification. Their retinae are linear, and are divided into distinct green-sensitive distal and UV and polarization-sensitive proximal portions. Each distal retina, moreover, has many tiers of photoreceptors with rhabdomeres the long axis of which are peculiarly oriented perpendicular to the light path. Based on detailed optical investigations, the lenses of these eyes are bifocal and project focused images onto specific retinal tiers. Behavioral experiments suggest that these larvae approach prey within their eyes' near-fields, and that they can correctly gauge prey distances even when conventional distance-vision mechanisms are unavailable. In the near-field of these eyes object distance determines which of the many retinal layers receive the best-focused images. This retinal organization could facilitate an unusual distance-vision mechanism. We here summarize past findings and discuss how these eyes allow Thermonectus larvae to be such successful predators.
Prevalence, Correlates, and Impact of Uncorrected Presbyopia in a Multiethnic Asian Population.
Kidd Man, Ryan Eyn; Fenwick, Eva Katie; Sabanayagam, Charumathi; Li, Ling-Jun; Gupta, Preeti; Tham, Yih-Chung; Wong, Tien Yin; Cheng, Ching-Yu; Lamoureux, Ecosse Luc
2016-08-01
To examine the prevalence, correlates, and impact of uncorrected presbyopia on vision-specific functioning (VF) in a multiethnic Asian population. Population-based cross-sectional study. We included 7890 presbyopic subjects (3909 female; age range, 40-86 years) of Malay, Indian, and Chinese ethnicities from the Singapore Epidemiology of Eye Disease study. Presbyopia was classified as corrected and uncorrected based on self-reported near correction use. VF was assessed with the VF-11 questionnaire validated using Rasch analysis. Multivariable logistic and linear regression models were used to investigate the associations of sociodemographic and clinical parameters with uncorrected presbyopia, and its impact on VF, respectively. As myopia may mitigate the impact of noncorrection, we performed a subgroup analysis on myopic subjects only (n = 2742). In total, 2678 of 7890 subjects (33.9%) had uncorrected presbyopia. In multivariable models, younger age, male sex, Malay and Indian ethnicities, presenting distance visual impairment (any eye), and lower education and income levels were associated with higher odds of uncorrected presbyopia (all P < .05). Compared with corrected presbyopia, noncorrection was associated with worse overall VF and reduced ability to perform individual near and distance vision-specific tasks even after adjusting for distance VA and other confounders (all P < .05). Results were very similar for myopic individuals. One-third of presbyopic Singaporean adults did not have near correction. Given its detrimental impact on both near and distance VF, public health strategies to increase uptake of presbyopic correction in younger individuals, male individuals, and those of Malay and Indian ethnicities are needed. Copyright © 2016 Elsevier Inc. All rights reserved.
Liu, Ting; Zhu, Xiaomin; Chen, Kaijian; Bai, Ji
2017-07-01
To evaluate the refractive outcomes of balanced salt solution infiltration during small-incision lenticule extraction (SMILE).This randomized prospective study enrolled 52 patients (104 eyes) with myopic astigmatism. Patients underwent SMILE to correct the myopic astigmatism in Daping Hospital of the Third Military Medical University between January and July 2013. One eye of each patient received traditional SMILE (control group) and the other received a modified SMILE procedure (liquid infiltration group). The corrected distance visual acuity (CDVA), postoperative uncorrected distance visual acuity (UDVA), refraction, wavefront aberration, intraocular pressure (IOP), modulation transfer function (MTF) cut-off frequency, and objective scattering index (OSI) were evaluated.UDVA in the liquid infiltration group was significantly higher than that in the control group at 1 day postoperatively, but not at 1 month after surgery. Moreover, OSI and MTF cut-off frequency in the liquid infiltration group were higher than those in the control group at early follow-up. However, no significant intergroup difference was observed in the OSI and MTF cut-off frequency at 3 months after surgery. In addition, the predictability was better in the liquid infiltration group than in the control group. The changes of horizontal coma in the liquid infiltration group were lesser than those in the control group. However, no intergroup difference was observed in the reduction of IOP at 1 month after surgery.The modified SMILE procedure results in better visual outcomes than did the traditional SMILE procedure when used for treating myopic astigmatism.
Lagrèze, Wolf A; Schaeffel, Frank
2017-09-04
Nearsightedness (myopia) has become more common around the world recently, mainly because of changes in visual, educational, and recreational behavior. The question arises how the risk of myopia and its progression can be reduced. This would lessen the prevalence and severity of myopia and also lower the risk of secondary diseases that impair visual acuity. The PubMed/Medline database was selectively searched for pertinent literature. The risk of myopia is lowered by exposure to daylight and increased by activities performed at short visual distances (close-up work). A person with little exposure to daylight has a fivefold risk of developing myopia, which can rise as high as a 16-fold risk if that person also performs close-up work. Two meta-analyses and a large randomized clinical trial from Asia have shown that the progression of myopia over two years of observation can be lessened by up to 0.71 diopters by the administration of atropine eye drops in a concentration that has practically no serious side effects. At higher doses, myopia progresses more severely than in the placebo group after the cessation of therapy. This is an off-label treatment. A weaker effect on progression has been shown for multifocal optical corrections that include both a distance correction and a correction for near vision. Effective pharmacological and optical measures are now available to lessen the progression of myopia. The increasing prevalence of myopia should motivate pediatricians, parents, and schools to pay attention to risk factors such as close-up work and lack of daylight exposure, particularly in view of the increased use of digital media.
Comparison of distance and near visual acuity in patients with vision loss due to cataract.
Mercado, Carmel L; Doroslovački, Pavle; Wang, Jiangxia; Siddiqui, Aazim A; Kolker, Andrew F; Kolker, Richard J
2017-02-01
The purpose of this study was to assess whether there is a disparity in distance and near best-corrected visual acuity (BCVA) in cataract eyes. 102 patients with cataract (N = 121 eyes) were seen in clinic between January and November 2013 at the Wilmer Eye Institute Comprehensive Eye Service. An age-related macular degeneration (ARMD) group (N = 27 eyes) was also identified for comparison. Distance and near BCVA were measured as part of the standard ophthalmic evaluation. Snellen measurements were converted to their LogMAR equivalents for statistical analysis. Near was better than distance BCVA with mean difference of 1.38 lines (P < 0.001) in the cataract eyes. This disparity was not seen in the ARMD eyes. Near-distance BCVA disparity is a statistically significant finding seen with cataracts. This may have further implications in patients with both cataract and ARMD as the presence of disparity may suggest a cataract etiology playing a greater role in vision loss. This comparison may be useful for surgical prognostication and as a quick triage tool in conjunction with, or in place of, a potential acuity meter and dilated near-pinhole test.
Alió, Jorge L; Plaza-Puche, Ana B; Javaloy, Jaime; Ayala, María José
2012-02-01
To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal intraocular lens (IOL) and an apodized diffractive multifocal IOL. Seventy-four consecutive eyes of 40 cataract patients (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 eyes implanted with a rotationally asymmetric multifocal IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); and diffractive group, 35 eyes implanted with an apodized diffractive multifocal IOL (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance and near visual acuity outcomes, contrast sensitivity, intraocular optical quality, and defocus curves were evaluated during 3-month follow-up. Calculation of the intraocular aberrations was performed by subtracting corneal aberrations from total ocular aberrations. Uncorrected near visual acuity and distance-corrected near visual acuity were better in the diffractive group than in the zonal refractive group (P=.01), whereas intermediate visual acuity (defocus +1.00 and +1.50 diopters) was better in the zonal refractive group. Photopic contrast sensitivity was significantly better in the zonal refractive group (P=.04). Wavefront aberrations (total, higher order, tilt, primary coma) were significantly higher in the zonal refractive group than in the diffractive group (P=.02). Both multifocal IOLs are able to successfully restore visual function after cataract surgery. The zonal refractive multifocal IOL provides better results in contrast sensitivity and intermediate vision, whereas the diffractive multifocal IOL provides better near vision at a closer distance. Copyright 2012, SLACK Incorporated.
Anderson, Alexander S; Marques, Tiago A; Shoo, Luke P; Williams, Stephen E
2015-01-01
Indices of relative abundance do not control for variation in detectability, which can bias density estimates such that ecological processes are difficult to infer. Distance sampling methods can be used to correct for detectability, but in rainforest, where dense vegetation and diverse assemblages complicate sampling, information is lacking about factors affecting their application. Rare species present an additional challenge, as data may be too sparse to fit detection functions. We present analyses of distance sampling data collected for a diverse tropical rainforest bird assemblage across broad elevational and latitudinal gradients in North Queensland, Australia. Using audio and visual detections, we assessed the influence of various factors on Effective Strip Width (ESW), an intuitively useful parameter, since it can be used to calculate an estimate of density from count data. Body size and species exerted the most important influence on ESW, with larger species detectable over greater distances than smaller species. Secondarily, wet weather and high shrub density decreased ESW for most species. ESW for several species also differed between summer and winter, possibly due to seasonal differences in calling behavior. Distance sampling proved logistically intensive in these environments, but large differences in ESW between species confirmed the need to correct for detection probability to obtain accurate density estimates. Our results suggest an evidence-based approach to controlling for factors influencing detectability, and avenues for further work including modeling detectability as a function of species characteristics such as body size and call characteristics. Such models may be useful in developing a calibration for non-distance sampling data and for estimating detectability of rare species.
Anderson, Alexander S.; Marques, Tiago A.; Shoo, Luke P.; Williams, Stephen E.
2015-01-01
Indices of relative abundance do not control for variation in detectability, which can bias density estimates such that ecological processes are difficult to infer. Distance sampling methods can be used to correct for detectability, but in rainforest, where dense vegetation and diverse assemblages complicate sampling, information is lacking about factors affecting their application. Rare species present an additional challenge, as data may be too sparse to fit detection functions. We present analyses of distance sampling data collected for a diverse tropical rainforest bird assemblage across broad elevational and latitudinal gradients in North Queensland, Australia. Using audio and visual detections, we assessed the influence of various factors on Effective Strip Width (ESW), an intuitively useful parameter, since it can be used to calculate an estimate of density from count data. Body size and species exerted the most important influence on ESW, with larger species detectable over greater distances than smaller species. Secondarily, wet weather and high shrub density decreased ESW for most species. ESW for several species also differed between summer and winter, possibly due to seasonal differences in calling behavior. Distance sampling proved logistically intensive in these environments, but large differences in ESW between species confirmed the need to correct for detection probability to obtain accurate density estimates. Our results suggest an evidence-based approach to controlling for factors influencing detectability, and avenues for further work including modeling detectability as a function of species characteristics such as body size and call characteristics. Such models may be useful in developing a calibration for non-distance sampling data and for estimating detectability of rare species. PMID:26110433
[Binocular fusion method for prevention of myopia].
Xu, G D
1989-03-01
When looking at a far object with two eyes, relaxation of convergence and accommodation occurred and accompanied by binocular fusion. Using this phenomenon a method of binocular fusion of targets was designed, that is the distance between two targets are just the same as the distance between two visual lines, while looking at a far object. During the images of the targets are fused, the accommodation and convergence are relaxed concomitantly; thus a result of correction of pseudomyopia and prevention of myopia is achieved. By means of binocular fusion, the eye muscle exercises were conducted and resulted in not only the far point further but also the near point closer. The skiascopic examination carried out at the same time of binocular fusion showed that the degrees of relaxed accommodation was 97.9% that of looking at an object in far distance. The above results indicated that the binocular fusion method had excellent effect on the prevention of myopia. This method is simple and feasible, conforms to the visual physiology, and thus can be widely adopted.
Asymmetrical number-space mapping in the avian brain.
Rugani, Rosa; Vallortigara, Giorgio; Vallini, Barbara; Regolin, Lucia
2011-03-01
When trained to peck a selected position in a sagittally-oriented series of identical food containers, and then required to generalize to an identical series rotated by 90°, chicks identify as correct only the target position from the left end, while choosing the right one at chance. Here we show that when accustomed to systematic changes in inter-elements distances during training or faced with similar spatial changes at test, chicks identify as correct both the target positions from left and right ends. However, ordinal position is spontaneously encoded even when inter-element distances are kept fixed during training (in spite of the fact that distances between elements suffice for target identification without any numerical computation). We explain these findings in terms of intra-hemispheric coupling of bilateral numerical (ordinal) representation and unilateral (right hemispheric) spatial representation of the number line, producing differential allocation of attention in the left and right visual hemifields. Copyright © 2010 Elsevier Inc. All rights reserved.
Visual impairment, visual functioning, and quality of life assessments in patients with glaucoma.
Parrish, R K
1996-01-01
BACKGROUND/PURPOSE: To determine the relation between visual impairment, visual functioning, and the global quality of life in patients with glaucoma. METHODS: Visual impairment, defined with the American Medical Association Guides to the Evaluation of Permanent Impairment; visual functioning, measured with the VF-14 and the Field Test Version of the National Eye Institute-Visual Functioning Questionnaire (NEI-VFQ); and the global quality of life, assessed with the Medical Outcomes Study 36-Item Short Form Health Survey (SF-36), were determined in 147 consecutive patients with glaucoma. RESULTS: None of the SF-36 domains demonstrated more than a weak correlation with visual impairment. The VF-14 scores were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual impairment. Of the twelve NEI-VFQ scales, distance activities and vision specific dependency were moderately correlated with visual field impairment; vision specific social functioning, near activities, vision specific role difficulties, general vision, vision specific mental health, color vision, and driving were modestly correlated; visual pain was weakly correlated; and two were not significantly correlated. Correcting for visual actuity weakened the strength of the correlation coefficients. CONCLUSIONS: The SF-36 is unlikely to be useful in determining visual impairment in patients with glaucoma. Based on the moderate correlation between visual field impairment and the VF-14 score, this questionnaire may be generalizable to patients with glaucoma. Several of the NEI-VFQ scales correlate with visual field impairment scores in patients with a wide range of glaucomatous damage. PMID:8981717
Current Management of Presbyopia
Papadopoulos, Pandelis A.; Papadopoulos, Alexandros P.
2014-01-01
Presbyopia is a physiologic inevitability that causes gradual loss of accommodation during the fifth decade of life. The correction of presbyopia and the restoration of accommodation are considered the final frontier of refractive surgery. Different approaches on the cornea, the crystalline lens and the sclera are being pursued to achieve surgical correction of this disability. There are however, a number of limitations and considerations that have prevented widespread acceptance of surgical correction for presbyopia. The quality of vision, optical and visual distortions, regression of effect, complications such as corneal ectasia and haze, anisometropia after monovision correction, impaired distance vision and the invasive nature of the currently techniques have limited the utilization of presbyopia surgery. The purpose of this paper is to provide an update of current procedures available for presbyopia correction and their limitations. PMID:24669140
Photorefractive keratectomy with a small spot laser and tracker.
Pallikaris, I G; Koufala, K I; Siganos, D S; Papadaki, T G; Katsanevaki, V J; Tourtsan, V; McDonald, M B
1999-01-01
The Autonomous Technologies LADARVision excimer laser system utilizes an eye tracking mechanism and a small spot for photorefractive keratectomy. One hundred and two eyes of 102 patients were treated for -1.50 to -6.25 D of spherical myopia at the spectacle plane using a 6-mm diameter ablation zone. One year follow-up was available for 93 eyes (91%). Uncorrected visual acuity for eyes treated for distance vision was 20/40 or better in 99% (n = 90), and 20/20 or better in 70% (n = 64) of eyes at 12 months. Spectacle-corrected visual acuity was 20/25 or better in all 92 eyes reported; no eye lost more than 2 lines of spectacle-corrected visual acuity, and only 1 eye (1.0%) experienced a loss of 2 lines (20/12.5 to 20/20) at 1 year. The refractive result was within +/- 0.50 D of the desired correction in 75% (n = 70), and within +/- 1.00 D in 93% (n = 86) of eyes at 12 months. Refractive stability was achieved between 3 and 6 months. Corneal haze was graded as trace or less in 100% of the 93 eyes. No significant reductions were noted in contrast sensitivity or endothelial cell density. Patients treated with the Autonomous Technologies LADARVision excimer laser system for -1.50 to -6.25 D of spherical myopia with 1 year follow-up had uncorrected visual acuity of 20/20 or better in 70%, no significant loss of spectacle-corrected visual acuity, no reduction of endothelial cell density or contrast sensitivity, and low levels of corneal haze.
Near visual acuity for everyday activities with accommodative and monofocal intraocular lenses.
Sanders, Donald R; Sanders, Monica L
2007-10-01
To determine the levels of functional near visual acuity required for everyday social reading activities and to compare the levels to those attained with accommodative and monofocal intraocular lenses (LOLs). Font size equivalencies of an Early Treatment Diabetic Retinopathy Study near chart and a variety of commonly read print objects were determined and correlated to the findings of distance-corrected near vision measurements with 2 accommodative (Tetraflex, 1CU) and 1 monofocal (Acrysof MA30) IOLs. The smallest print objects studied were sweetener packets with type between 20/40 (Jaeger [J] 5) and 20/50 (J6). Type in classified ads, stock quotations, and pocket bibles was 20/50 (J6), type in a telephone directory was 20/63 (J8), and type in standard newspapers, journals, and magazines was 20/80 (J9). Tested monocularly, 88% of Tetraflex, 40% of ICU, and 7% of Acrysof MA30 eyes had distance-corrected near vision sufficient to read newspaper and telephone directory print, and 63% of Tetraflex, 30% of 1CU, and 0% of Acrysof MA30 eyes could read classified ads, stock quotations, and pocket bibles, respectively. Tested binocularly after bilateral implantation, 96% of Tetraflex patients could read telephone directory print and 89% could read ads, stock quotations, and pocket bibles. Functional near visual acuity is not equivalent to the bottom-line objective at 20/20 (J1) near visual acuity. No print size was found at or smaller than 20/40 (J5), indicating that a requirement of nearly perfect near visual acuity, while desirable, may not be necessary for patients' social reading needs for accommodative IOLs.
Tomita, Minoru; Sotoyama, Yuko; Yukawa, Satoshi; Nakamura, Tadayuki
2013-01-01
Purpose To compare the incidence of diffuse lamellar keratitis (DLK) after laser in situ keratomileusis (LASIK) with flap creation using the Femto LDV and IntraLase™ FS60 femtosecond lasers.0 Methods A total of 818 consecutive myopic eyes had LASIK performed using either Femto LDV or IntraLase FS60 for flap creation. The same excimer laser, the Allegretto Wave® Eye-Q Laser, was used for correcting refractive errors for all patients. In the preoperative examination, uncorrected distance visual acuity, corrected distance visual acuity, and manifest refraction spherical equivalent were measured. At the postop examination, the same examinations were performed along with a slit-lamp biomicroscopic examination, and patients with DLK were classified into stages. For the statistical analysis of the DLK occurrence rate and the visual and refractive outcomes, the Mann-Whitney’s U-test was used. Results In the Femto LDV group with 514 eyes, 42 (8.17%) had DLK. In the IntraLase FS60 group with 304 eyes, 114 (37.5%) had DLK. There was a statistically significant difference in the DLK incidence rate between these groups (P < 0.0001). Both groups had excellent visual and refractive outcomes. Although low levels of DLK were observed for both groups, they did not affect visual acuity. Conclusion While there were significantly fewer incidences of low level DLK when using Femto LDV, neither femtosecond laser induced high levels of DLK, and any postoperative DLK cleared up within 1 week. Therefore, both lasers provide excellent results, with no clinical differences, and both excel at flap creation for LASIK. PMID:23874077
Kaluzny, Bartlomiej J; Cieslinska, Iwona; Mosquera, Samuel A; Verma, Shwetabh
2016-02-01
Transepithelial photorefractive keratectomy (tPRK), where both the epithelium and stroma are removed in a single-step, is a relatively new procedure of laser refractive error correction. This study compares the 3-month results of myopia and compound myopic astigmatism correction by tPRK or conventional alcohol-assisted PRK (aaPRK).This prospective, nonrandomized, case-control study recruited 148 consecutive patients; 93 underwent tPRK (173 eyes) and 55 aaPRK (103 eyes). Refractive results, predictability, safety, and efficacy were evaluated during the 3-month follow-up. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), and mean refractive spherical equivalent (MRSE).Mean preoperative MRSE was -4.30 ± 1.72 D and -4.33 ± 1.96 D, respectively (P = 0.87). The 3-month follow-up rate was 82.1% in the tPRK group (n = 145) and 86.4% in aaPRK group (n = 90), P = 0.81. Postoperative UDVA was 20/20 or better in 97% and 94% of eyes, respectively (P = 0.45). In the tPRK and aaPRK groups, respectively, 13% and 21% of eyes lost 1 line of CDVA, and 30% and 31% gained 1 or 2 lines (P = 0.48). Mean postoperative MRSE was -0.14 ± 0.26 D in the tPRK group and -0.12 ± 0.20 D in the aaPRK group (P = 0.9). The correlation between attempted versus achieved MRSE was equally high in both groups.Single-step transepithelial PRK and conventional PRK provide very similar results 3 months postoperatively. These procedures are predictable, effective, and safe for correction of myopia and compound myopic astigmatism.
Hayashi, Ken; Yoshida, Motoaki; Hayashi, Hideyuki
2009-03-01
To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL. Comparative, nonrandomized, interventional study. Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL. All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs. At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances. Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P
Nuijts, Rudy M M A; Jonker, Soraya M R; Kaufer, Robert A; Lapid-Gortzak, Ruth; Mendicute, Javier; Martinez, Cristina Peris; Schmickler, Stefanie; Kohnen, Thomas
2016-02-01
To assess the clinical visual outcomes of bilateral implantation of Restor +2.5 diopter (D) multifocal intraocular lenses (IOLs) and contralateral implantation of a Restor +2.5 D multifocal IOL in the dominant eye and Restor +3.0 D multifocal IOL in the fellow eye. Multicenter study at 8 investigative sites. Prospective randomized parallel-group patient-masked 2-arm study. This study comprised adults requiring bilateral cataract extraction followed by multifocal IOL implantation. The primary endpoint was corrected intermediate visual acuity (CIVA) at 60 cm, and the secondary endpoint was corrected near visual acuity (CNVA) at 40 cm. Both endpoints were measured 3 months after implantation with a noninferiority margin of Δ = 0.1 logMAR. In total, 103 patients completed the study (53 bilateral, 50 contralateral). At 3 months, the mean CIVA at 60 cm was 0.13 logMAR and 0.10 logMAR in the bilateral group and contralateral group, respectively (difference 0.04 logMAR), achieving noninferiority. Noninferiority was not attained for CNVA at 40 cm; mean values at 3 months for bilateral and contralateral implantation were 0.26 logMAR and 0.11 logMAR, respectively (difference 0.15 logMAR). Binocular defocus curves suggested similar performance in distance vision between the 2 groups. Treatment-emergent ocular adverse events rates were similar between the groups. Bilateral implantation of the +2.5 D multifocal IOL resulted in similar distance as contralateral implantation of the +2.5 D multifocal IOL and +3.0 D multifocal IOL for intermediate vision (60 cm), while noninferiority was not achieved for near distances (40 cm). Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Outcomes of small incision lenticule extraction (SMILE) in low myopia.
Reinstein, Dan Z; Carp, Glenn I; Archer, Timothy J; Gobbe, Marine
2014-12-01
To report the visual and refractive outcomes of small incision lenticule extraction for low myopia using the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). A retrospective analysis of 120 consecutive small incision lenticule extraction procedures was performed for low myopia. Inclusion criteria were preoperative spherical equivalent refraction up to -3.50 diopters (D), cylinder up to 1.50 D, and corrected distance visual acuity of 20/20 or better. Outcomes analysis was performed for all eyes with 1-year follow-up according to the Standard Graphs for Reporting Refractive Surgery, and also including mesopic contrast sensitivity. One-year data were available for 110 eyes (92%). Preoperatively, mean spherical equivalent refraction was -2.61 ± 0.54 D (range: -1.03 to -3.50 D) and mean cylinder was 0.55 ± 0.38 D (range: 0.00 to 1.50 D). Postoperatively, mean spherical equivalent refraction was -0.05 ± 0.36 D (range: -0.94 to +1.25 D) and mean cylinder was ± 0.50 D in 84% and ± 1.00 D in 99% of eyes. Uncorrected distance visual acuity was 20/20 or better in 96% of eyes and 20/25 or better in 100% of eyes. One line of corrected distance visual acuity was lost in 9%, but no eyes lost two or more lines. There was an initial overcorrection in mean spherical equivalent refraction on day 1 (+0.37 D) as expected, which regressed to +0.10 D at 1 month and -0.05 D at 3 months, after which stability was reached (mean spherical equivalent refraction was -0.05 D at 1 year). Contrast sensitivity at 1 year was slightly increased at 3, 6, 12, and 18 cycles per degree (P < .05). Small incision lenticule extraction for low myopia was found to be safe and effective with outcomes similar to those previously reported for LASIK. Copyright 2014, SLACK Incorporated.
Loriaut, Patrick; Borderie, Vincent M; Laroche, Laurent
2015-09-01
To assess the clinical and refractive outcomes of femtosecond-assisted arcuate keratotomy in postkeratoplasty patients, and the accuracy of the incisions, using optical coherence tomography. This is a retrospective study of patients with high postkeratoplasty astigmatism. Patients with a minimum of 4 diopters (D) of postkeratoplasty regular astigmatism were included. The main outcome measures were corrected distance visual acuity, keratometry, corneal topography, and the depth of corneal incisions. Arcuate keratotomy procedures were performed using the IntraLase Femtosecond laser. The depth of keratotomies was set to 75% of the thinnest pachymetry. Twenty eyes of 20 patients were recruited in this study. The mean age at surgery was 51 years, and the mean follow-up period was 17 ± 7.9 months. The corrected distance visual acuity improved significantly from 20/60 preoperatively to 20/41 after surgery (P = 0.004). The mean preoperative and postoperative spherical equivalents were -4.34 ± 2.91 D and -4.44 ± 3.64 D, respectively (P = 0.49). The mean keratometric cylinder decreased from 9.45 ± 2.97 D (range, 4.2-15.2 D) to 4.64 ± 2.79 D (range, 1.4-11.8 D) (P < 0.001). There was no statistical difference between the mean surgical-induced astigmatism and the mean target-induced astigmatism (P = 0.313). The mean difference between the scheduled and actual incision depth was 10.5 ± 22.2 μm (P = 0.057). No complications occurred during the procedures. Femtosecond-assisted keratotomy seems to be a safe and efficient technique for the reduction of large amounts of corneal astigmatism. Although overcorrection and undercorrection may occur, the visual outcome is satisfactory. Optical coherence tomography analysis reports a good predictability of the depth of incisions.
Pedersen, Iben Bach; Ivarsen, Anders; Hjortdal, Jesper
2017-01-01
To evaluate 12-month changes in refraction, visual outcome, corneal densitometry, and postoperative aberrations after small incision lenticule extraction (SMILE) for myopic astigmatism. This 12-month prospective clinical trial comprised 101 eyes (101 patients) treated with SMILE for myopic astigmatism with cylinder of 0.75 to 4.00 diopters (D). The preoperative, 1-week, and 1-, 3-, 6-, 9-, and 12-month examinations included measurement of manifest refraction, uncorrected distance visual acuity (UDVA), and corrected (CDVA) distance visual acuity. Astigmatic error vector analysis was performed using Al-pin's method. Densitometry and aberrations were evaluated with Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany). Preoperative spherical equivalent averaged -6.78 ± 1.90 D with 1.81 ± 1.00 D in cylinder correction. After 12 months, 74% and 93% of the eyes were within ±0.50 and ±1.00 D of the attempted refraction, respectively. The logMAR UDVA and CDVA averaged 0.03 ± 0.16 and -0.08 ± 0.09, respectively. Vector analysis showed a with-the-rule undercorrection at 12 months with a mean difference vector of 0.31 D @ 91°. There was a minor counterclockwise rotation of the axis, with an arithmetic angle of error of 0.34° ± 14°. An undercorrection of approximately 11% per diopter of attempted correction was seen at 12 months. Spherical aberrations, coma, and higher order aberrations remained stable during the postoperative period (P < .09). After 12 months, no increase in densitometry could be identified. Treatment of astigmatism with SMILE seems to be predictable and effective, but with an astigmatic undercorrection of approximately 11% and a small counterclockwise rotation of the axis. [J Refract Surg. 2017;33(1):11-17.]. Copyright 2017, SLACK Incorporated.
Aslanides, Ioannis M; Kolli, Sai; Padroni, Sara; Padron, Sara; Arba Mosquera, Samuel
2012-05-01
To evaluate the long-term outcomes of aspheric corneal wavefront ablation profiles for excimer laser retreatment. Eighteen eyes that had previously undergone LASIK or photorefractive keratectomy (PRK) were retreated with LASIK using the corneal wavefront ablation profile. Custom Ablation Manager (SCHWIND eye-tech-solutions, Kleinostheim, Germany) software and the ESIRIS flying spot excimer laser system (SCHWIND) were used to perform the ablations. Refractive outcomes and wavefront data are reported up to 4 years after retreatment. Pre- and postoperative data were compared with Student t tests and (multivariate) correlation tests. P<.05 was considered statistically significant. A bilinear correlation of various postoperative wavefront aberrations versus planned correction and preoperative aberration was performed. Mean manifest refraction spherical equivalent (MRSE) before retreatment was -0.38±1.85 diopters (D) and -0.09±0.22 D at 6 months and -0.10±0.38 D at 4 years postoperatively. The reduction in MRSE was statistically significant at both postoperative time points (P<.005). Postoperative aberrations were statistically lower (spherical aberration P<.05; coma P<.005; root-mean-square higher order aberration P<.0001) at 4 years postoperatively. Distribution of the postoperative uncorrected distance visual acuity (P<.0001) and corrected distance visual acuity (P<.01) were statistically better than preoperative values. Aspheric corneal wavefront customization with the ESIRIS yields visual, optical, and refractive results comparable to those of other wavefront-guided customized techniques for the correction of myopia and myopic astigmatism. The corneal wavefront customized approach shows its strength in cases where abnormal optical systems are expected. Systematic wavefront customized corneal ablation appears safe and efficacious for retreatment cases. Copyright 2012, SLACK Incorporated.
Vilar, César; Hida, Wilson Takashi; de Medeiros, André Lins; Magalhães, Klayny Rafaella Pereira; de Moraes Tzelikis, Patrick Frensel; Chaves, Mario Augusto Pereira Dias; Motta, Antônio Francisco Pimenta; Carricondo, Pedro Carlos; Alves, Milton Ruiz; Nosé, Walton
2017-01-01
Purpose To compare visual outcomes and performance between bilateral implantation of a diffractive trifocal intraocular lens (IOL) Acrysof®PanOptix® TFNT00 and blended implantation of two different near add power bifocal IOLs: Acrysof® Restor® SV25T0 in dominant eye and Acrysof® Restor® SN6AD1 in the nondominant eye. Methods This prospective, nonrandomized, consecutive and comparative study assessed 20 patients (40 eyes) who had bilateral cataract surgery performed using the IOLs described. Patients were divided into groups, bilateral trifocal implant and blended implant. Evaluation included measurement of binocular uncorrected and corrected distance visual acuity at 4 m (UDVA, CDVA) and uncorrected intermediate (60 cm) and near (at 40 cm) visual acuity; contrast sensitivity (CS) and visual defocus curve. Results Postoperative CDVA comparison showed no statistical significance between groups. UDVA was significantly better in the trifocal groups. Under photopic conditions, the trifocal group had better CS in higher frequencies with and without glare. The binocular defocus curve demonstrated a trifocal behavior in both groups, with the bilateral trifocal group exhibiting better performance for intermediate vision. Conclusion Both lens combinations were able to provide good near, intermediate and distance vision, with the trifocal group showing significantly better performance at intermediate distances and better CS under photopic conditions. PMID:28814826
Yokogawa, Hideaki; Sanchez, P James; Mayko, Zachary M; Straiko, Michael D; Terry, Mark A
2017-03-01
To report the clinical efficacy of astigmatism correction with toric intraocular lenses (IOLs) in patients undergoing the Descemet membrane endothelial keratoplasty (DMEK) triple procedure and to evaluate the accuracy of the correction. Fifteen eyes of 10 patients who received cataract extraction, toric IOL placement, and DMEK surgery for Fuchs corneal dystrophy and cataracts were evaluated. The cylinder power of toric IOLs was determined by an online toric calculator with keratoscopy measurements obtained using Scheimpflug corneal imaging. Prediction errors were assessed as a difference vector between the anticipated minus postoperative residual astigmatism. At 10.1 ± 4.9 months postoperatively, 8/13 (61.5%) of eyes achieved uncorrected distance visual acuity better than 20/40. Mean best spectacle-corrected distance visual acuity (logMAR) improved from 0.21 ± 0.15 preoperatively to 0.08 ± 0.12 postoperatively (P < 0.01). The magnitude of refractive astigmatism was also significantly decreased from 2.23 ± 1.10 D (range 0.75-4.25 D) preoperatively to 0.87 ± 0.75 D (range 0.00-3.00 D) postoperatively (P < 0.01). In 1 eye with rotational misalignment by 43 degrees, we found no improvement of astigmatism. The prediction error of astigmatism at the corneal plane was 0.77 ± 0.54 D (range 0.10-1.77 D). Four eyes with preoperative "with-the-rule" corneal astigmatism had postoperative "against-the-rule" refractive astigmatism. For patients with Fuchs corneal dystrophy and cataracts, use of toric IOLs might be a valuable option in triple DMEK surgery. Additionally, care should be taken to prevent excessive IOL rotation.
Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki
2017-01-01
AIM To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. METHODS Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). RESULTS The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB (P<0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB (P=0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB (P<0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. CONCLUSION Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended. PMID:29062776
Hirasawa, Kazunori; Ito, Hikaru; Ohori, Yukari; Takano, Yui; Shoji, Nobuyuki
2017-01-01
To evaluate the refractive correction for standard automated perimetry (SAP) in eyes with refractive multifocal contact lenses (CL) in healthy young participants. Twenty-nine eyes of 29 participants were included. Accommodation was paralyzed in all participants with 1% cyclopentolate hydrochloride. SAP was performed using the Humphrey SITA-standard 24-2 and 10-2 protocol under three refractive conditions: monofocal CL corrected for near distance (baseline); multifocal CL corrected for distance (mCL-D); and mCL-D corrected for near vision using a spectacle lens (mCL-N). Primary outcome measures were the foveal threshold, mean deviation (MD), and pattern standard deviation (PSD). The foveal threshold of mCL-N with both the 24-2 and 10-2 protocols significantly decreased by 2.2-2.5 dB ( P <0.001), while that of mCL-D with the 24-2 protocol significantly decreased by 1.5 dB ( P =0.0427), as compared with that of baseline. Although there was no significant difference between the MD of baseline and mCL-D with the 24-2 and 10-2 protocols, the MD of mCL-N was significantly decreased by 1.0-1.3 dB ( P <0.001) as compared with that of both baseline and mCL-D, with both 24-2 and 10-2 protocols. There was no significant difference in the PSD among the three refractive conditions with both the 24-2 and 10-2 protocols. Despite the induced mydriasis and the optical design of the multifocal lens used in this study, our results indicated that, when the dome-shaped visual field test is performed with eyes with large pupils and wearing refractive multifocal CLs, distance correction without additional near correction is to be recommended.
An approach to instrument qualified visual range
NASA Astrophysics Data System (ADS)
Courtade, Benoît; Bonnet, Jordan; Woodruff, Chris; Larson, Josiah; Giles, Andrew; Sonde, Nikhil; Moore, C. J.; Schimon, David; Harris, David Money; Pond, Duane; Way, Scott
2008-04-01
This paper describes a system that calculates aircraft visual range with instrumentation alone. A unique message is encoded using modified binary phase shift keying and continuously flashed at high speed by ALSF-II runway approach lights. The message is sampled at 400 frames per second by an aircraft borne high-speed camera. The encoding is designed to avoid visible flicker and minimize frame rate. Instrument qualified visual range is identified as the largest distance at which the aircraft system can acquire and verify the correct, runway-specific signal. Scaled testing indicates that if the system were implemented on one full ALSF-II fixture, instrument qualified range could be established at 5 miles in clear weather conditions.
Enhancing multi-view autostereoscopic displays by viewing distance control (VDC)
NASA Astrophysics Data System (ADS)
Jurk, Silvio; Duckstein, Bernd; Renault, Sylvain; Kuhlmey, Mathias; de la Barré, René; Ebner, Thomas
2014-03-01
Conventional multi-view displays spatially interlace various views of a 3D scene and form appropriate viewing channels. However, they only support sufficient stereo quality within a limited range around the nominal viewing distance (NVD). If this distance is maintained, two slightly divergent views are projected to the person's eyes, both covering the entire screen. With increasing deviations from the NVD the stereo image quality decreases. As a major drawback in usability, the manufacturer so far assigns this distance. We propose a software-based solution that corrects false view assignments depending on the distance of the viewer. Our novel approach enables continuous view adaptation based on the calculation of intermediate views and a column-bycolumn rendering method. The algorithm controls each individual subpixel and generates a new interleaving pattern from selected views. In addition, we use color-coded test content to verify its efficacy. This novel technology helps shifting the physically determined NVD to a user-defined distance thereby supporting stereopsis. The recent viewing positions can fall in front or behind the NVD of the original setup. Our algorithm can be applied to all multi-view autostereoscopic displays — independent of the ascent or the periodicity of the optical element. In general, the viewing distance can be corrected with a factor of more than 2.5. By creating a continuous viewing area the visualized 3D content is suitable even for persons with largely divergent intraocular distance — adults and children alike — without any deficiency in spatial perception.
Comparing artistic and geometrical perspective depictions of space in the visual field
Baldwin, Joseph; Burleigh, Alistair; Pepperell, Robert
2014-01-01
Which is the most accurate way to depict space in our visual field? Linear perspective, a form of geometrical perspective, has traditionally been regarded as the correct method of depicting visual space. But artists have often found it is limited in the angle of view it can depict; wide-angle scenes require uncomfortably close picture viewing distances or impractical degrees of enlargement to be seen properly. Other forms of geometrical perspective, such as fisheye projections, can represent wider views but typically produce pictures in which objects appear distorted. In this study we created an artistic rendering of a hemispherical visual space that encompassed the full visual field. We compared it to a number of geometrical perspective projections of the same space by asking participants to rate which best matched their visual experience. We found the artistic rendering performed significantly better than the geometrically generated projections. PMID:26034563
Comparing artistic and geometrical perspective depictions of space in the visual field.
Baldwin, Joseph; Burleigh, Alistair; Pepperell, Robert
2014-01-01
Which is the most accurate way to depict space in our visual field? Linear perspective, a form of geometrical perspective, has traditionally been regarded as the correct method of depicting visual space. But artists have often found it is limited in the angle of view it can depict; wide-angle scenes require uncomfortably close picture viewing distances or impractical degrees of enlargement to be seen properly. Other forms of geometrical perspective, such as fisheye projections, can represent wider views but typically produce pictures in which objects appear distorted. In this study we created an artistic rendering of a hemispherical visual space that encompassed the full visual field. We compared it to a number of geometrical perspective projections of the same space by asking participants to rate which best matched their visual experience. We found the artistic rendering performed significantly better than the geometrically generated projections.
Identification of Vibrotactile Patterns Encoding Obstacle Distance Information.
Kim, Yeongmi; Harders, Matthias; Gassert, Roger
2015-01-01
Delivering distance information of nearby obstacles from sensors embedded in a white cane-in addition to the intrinsic mechanical feedback from the cane-can aid the visually impaired in ambulating independently. Haptics is a common modality for conveying such information to cane users, typically in the form of vibrotactile signals. In this context, we investigated the effect of tactile rendering methods, tactile feedback configurations and directions of tactile flow on the identification of obstacle distance. Three tactile rendering methods with temporal variation only, spatio-temporal variation and spatial/temporal/intensity variation were investigated for two vibration feedback configurations. Results showed a significant interaction between tactile rendering method and feedback configuration. Spatio-temporal variation generally resulted in high correct identification rates for both feedback configurations. In the case of the four-finger vibration, tactile rendering with spatial/temporal/intensity variation also resulted in high distance identification rate. Further, participants expressed their preference for the four-finger vibration over the single-finger vibration in a survey. Both preferred rendering methods with spatio-temporal variation and spatial/temporal/intensity variation for the four-finger vibration could convey obstacle distance information with low workload. Overall, the presented findings provide valuable insights and guidance for the design of haptic displays for electronic travel aids for the visually impaired.
The zone of comfort: Predicting visual discomfort with stereo displays
Shibata, Takashi; Kim, Joohwan; Hoffman, David M.; Banks, Martin S.
2012-01-01
Recent increased usage of stereo displays has been accompanied by public concern about potential adverse effects associated with prolonged viewing of stereo imagery. There are numerous potential sources of adverse effects, but we focused on how vergence–accommodation conflicts in stereo displays affect visual discomfort and fatigue. In one experiment, we examined the effect of viewing distance on discomfort and fatigue. We found that conflicts of a given dioptric value were slightly less comfortable at far than at near distance. In a second experiment, we examined the effect of the sign of the vergence–accommodation conflict on discomfort and fatigue. We found that negative conflicts (stereo content behind the screen) are less comfortable at far distances and that positive conflicts (content in front of screen) are less comfortable at near distances. In a third experiment, we measured phoria and the zone of clear single binocular vision, which are clinical measurements commonly associated with correcting refractive error. Those measurements predicted susceptibility to discomfort in the first two experiments. We discuss the relevance of these findings for a wide variety of situations including the viewing of mobile devices, desktop displays, television, and cinema. PMID:21778252
The zone of comfort: Predicting visual discomfort with stereo displays.
Shibata, Takashi; Kim, Joohwan; Hoffman, David M; Banks, Martin S
2011-07-21
Recent increased usage of stereo displays has been accompanied by public concern about potential adverse effects associated with prolonged viewing of stereo imagery. There are numerous potential sources of adverse effects, but we focused on how vergence-accommodation conflicts in stereo displays affect visual discomfort and fatigue. In one experiment, we examined the effect of viewing distance on discomfort and fatigue. We found that conflicts of a given dioptric value were slightly less comfortable at far than at near distance. In a second experiment, we examined the effect of the sign of the vergence-accommodation conflict on discomfort and fatigue. We found that negative conflicts (stereo content behind the screen) are less comfortable at far distances and that positive conflicts (content in front of screen) are less comfortable at near distances. In a third experiment, we measured phoria and the zone of clear single binocular vision, which are clinical measurements commonly associated with correcting refractive error. Those measurements predicted susceptibility to discomfort in the first two experiments. We discuss the relevance of these findings for a wide variety of situations including the viewing of mobile devices, desktop displays, television, and cinema.
Combining zonal refractive and diffractive aspheric multifocal intraocular lenses.
Muñoz, Gonzalo; Albarrán-Diego, César; Javaloy, Jaime; Sakla, Hani F; Cerviño, Alejandro
2012-03-01
To assess visual performance with the combination of a zonal refractive aspheric multifocal intraocular lens (MIOL) (Lentis Mplus, Oculentis GmbH) and a diffractive aspheric MIOL (Acri.Lisa 366, Acri.Tech GmbH). This prospective interventional cohort study comprised 80 eyes from 40 cataract patients (mean age: 65.5±7.3 years) who underwent implantation of the Lentis Mplus MIOL in one eye and Acri.Lisa 366 MIOL in the fellow eye. The main outcome measures were refraction; monocular and binocular uncorrected and corrected distance, intermediate, and near visual acuities; monocular and binocular defocus curves; binocular photopic contrast sensitivity function compared to a monofocal intraocular lens (IOL) control group (40 age-matched pseudophakic patients implanted with the AR-40e [Abbott Medical Optics]); and quality of vision questionnaire. Binocular uncorrected visual acuities were 0.12 logMAR (0.76 decimal) or better at all distances measured between 6 m and 33 cm. The Lentis Mplus provided statistically significant better vision than the Acri.Lisa at distances between 2 m and 40 cm, and the Acri.Lisa provided statistically significant better vision than the Lentis Mplus at 33 cm. Binocular defocus curve showed little drop-off at intermediate distances. Photopic contrast sensitivity function for distance and near were similar to the monofocal IOL control group except for higher frequencies. Moderate glare (15%), night vision problems (12.5%), and halos (10%) were reported. Complete independence of spectacles was achieved by 92.5% of patients. The combination of zonal refractive aspheric and diffractive aspheric MIOLs resulted in excellent uncorrected binocular distance, intermediate, and near vision, with low incidence of significant photic phenomena and high patient satisfaction. Copyright 2012, SLACK Incorporated.
Fouda, Sameh Mosaad; Al Aswad, Mahmoud A; Ibrahim, Basem M; Bori, Ashraf; Mattout, Hala K
2016-12-01
This study aimed to evaluate the safety and efficacy of retropupillary fixation of an iris-claw intraocular lens (IOL; Verisyse polymethyl methacrylate IOL, Abbott Medical Optics [AMO], Netherlands) for the surgical correction of aphakia in microspherophakic eyes without sufficient capsular support. This was a prospective, interventional, noncomparative case series. This interventional case series comprised 17 eyes of 9 microspherophakic patients. Retropupillary fixation of the Verisyse iris-claw IOL (AMO) was performed in all cases. The surgical time was measured. Corrected distance visual acuity, astigmatism, intraocular pressure (IOP), tissue reaction, pigment dispersion, and stability of the IOL were studied 1 day, 3 days, 1 week, 2 weeks, 1 month, and 6 months postoperatively. Eight patients had familial microspherophakia and one patient had Marfan's syndrome. Eighty-two percent of the cases achieved a visual acuity of 0.3 or better. There was no significant postoperative inflammatory reaction. Transient elevation of IOP was recorded in two cases in the 1st week only. One IOL developed disengagement of one of the haptics from the iris and was successfully re-engaged. All the other IOLs were well centered and stable. The mean surgical time was 18.0 ± 4.5 min. Retropupillary fixation of an iris-claw IOL is a safe and effective procedure that provides early visual recovery. It is also a time-saving method for correcting aphakia in microspherophakic eyes without sufficient capsular support.
Multislice CT perfusion imaging of the lung in detection of pulmonary embolism
NASA Astrophysics Data System (ADS)
Hong, Helen; Lee, Jeongjin
2006-03-01
We propose a new subtraction technique for accurately imaging lung perfusion and efficiently detecting pulmonary embolism in chest MDCT angiography. Our method is composed of five stages. First, optimal segmentation technique is performed for extracting same volume of the lungs, major airway and vascular structures from pre- and post-contrast images with different lung density. Second, initial registration based on apex, hilar point and center of inertia (COI) of each unilateral lung is proposed to correct the gross translational mismatch. Third, initial alignment is refined by iterative surface registration. For fast and robust convergence of the distance measure to the optimal value, a 3D distance map is generated by the narrow-band distance propagation. Fourth, 3D nonlinear filter is applied to the lung parenchyma to compensate for residual spiral artifacts and artifacts caused by heart motion. Fifth, enhanced vessels are visualized by subtracting registered pre-contrast images from post-contrast images. To facilitate visualization of parenchyma enhancement, color-coded mapping and image fusion is used. Our method has been successfully applied to ten patients of pre- and post-contrast images in chest MDCT angiography. Experimental results show that the performance of our method is very promising compared with conventional methods with the aspects of its visual inspection, accuracy and processing time.
Zhang, Zhuang; Zhao, Rujin; Liu, Enhai; Yan, Kun; Ma, Yuebo
2018-06-15
This article presents a new sensor fusion method for visual simultaneous localization and mapping (SLAM) through integration of a monocular camera and a 1D-laser range finder. Such as a fusion method provides the scale estimation and drift correction and it is not limited by volume, e.g., the stereo camera is constrained by the baseline and overcomes the limited depth range problem associated with SLAM for RGBD cameras. We first present the analytical feasibility for estimating the absolute scale through the fusion of 1D distance information and image information. Next, the analytical derivation of the laser-vision fusion is described in detail based on the local dense reconstruction of the image sequences. We also correct the scale drift of the monocular SLAM using the laser distance information which is independent of the drift error. Finally, application of this approach to both indoor and outdoor scenes is verified by the Technical University of Munich dataset of RGBD and self-collected data. We compare the effects of the scale estimation and drift correction of the proposed method with the SLAM for a monocular camera and a RGBD camera.
Luck, Jonathan
2010-07-01
I report a case of pellucid marginal degeneration (PMD) with cataract that was successfully treated with implantation of an ultra-high-power customized bitoric AT.Comfort 646TLC intraocular lens (IOL). The preoperative uncorrected distance visual acuity (UDVA) was 6/120 and the corrected distance visual acuity (CDVA), 6/24 with 10.9 diopters (D) of keratometric astigmatism on Scheimpflug imaging. After implantation of an IOL with -0.5 +16.0 x 170, the UDVA was 6/9 with a manifest refraction of +0.25 +1.25 x 150 and the CDVA, 6/6(-1). No surgical complications or postoperative problems occurred, and the patient was very satisfied with the outcome. A longer follow-up is required to confirm this favorable clinical result. The author has no financial or proprietary interest in any material or method mentioned. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Kohnen, Thomas; Herzog, Michael; Hemkeppler, Eva; Schönbrunn, Sabrina; De Lorenzo, Nina; Petermann, Kerstin; Böhm, Myriam
2017-12-01
To evaluate visual performance after implantation of a quadrifocal intraocular lens (IOL). Setting: Department of Ophthalmology, Goethe University, Frankfurt, Germany. Twenty-seven patients (54 eyes) received bilateral implantation of the PanOptix IOL (AcrySof IQ PanOptixTM; Alcon Research, Fort Worth, Texas, USA) pre-enrollment. Exclusion criteria were previous ocular surgeries, corneal astigmatism of >1.5 diopter (D), ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 3 months including manifest refraction; uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) in 4 m, 80 cm, 60 cm, and 40 cm slit-lamp examination; defocus testing; contrast sensitivity (CS) under photopic and mesopic conditions; and a questionnaire on subjective quality of vision, optical phenomena, and spectacle independence was performed. At 3 months postoperatively, UCVA and DCVA in 4 m, 80 cm, 60 cm, and 40 cm (logMAR), defocus curves, CS, and quality-of-vision questionnaire results. Mean spherical equivalent was -0.04 ± 0.321 D 3 months postoperatively. Binocular UCVA at distance, intermediate (80 cm, 60 cm), and near was 0.00 ± 0.094 logMAR, 0.09 ± 0.107 logMAR, 0.00 ± 0.111 logMAR, and 0.01 ± 0.087 logMAR, respectively. Binocular defocus curve showed peaks with best visual acuity (VA) at 0.00 D (-0.07 logMAR) and -2.00 D (-0.02 logMAR). Visual performance of the PanOptix IOL showed good VA at all distances; particularly good intermediate VA (logMAR > 0.1), with best VA at 60 cm; and high patient satisfaction and spectacle independence 3 months postoperatively. Copyright © 2017 Elsevier Inc. All rights reserved.
[Clinical results after implantation of a new segmental refractive multifocal intraocular lens].
Thomas, B C; Auffarth, G U; Philips, R; Novák, J; Blazek, J; Adamkova, H; Rabsilber, T M
2013-11-01
The aim of the study was a clinical evaluation of an intraocular lens (IOL) with a segmental multifocal optic design and near addition of + 3.0 D as part of a CE approval study. In a multicenter study the LENTIS Mplus LS-312 MF IOL (Oculentis) was implanted in 134 eyes of 79 patients with a mean age of 68 ± 12 years. The multifocality is achieved by implementation of a distance part and a segmented near sector. Three months after surgery, uncorrected and best corrected distance visual acuity (UCDVA and BCDVA, respectively), near visual acuity (UCNVA and BCNVA, respectively), contrast vision and patient satisfaction (questionnaire) were evaluated. The IOLs were implanted uneventfully either unilaterally or bilaterally and 3 months postoperatively (n = 86 eyes) the following mean visual acuities were obtained (logMAR): UCDVA = 0.05, BCDVA = - 0.01, UCNVA = 0.09 and BCNVA = 0.02. Contrast sensitivity (n = 25 eyes) was within normal limits. Of the 66 questioned patients 10.6% spontaneously reported halos and 3% glare. This new innovative multifocal IOL concept showed very good functional results as well as high patient satisfaction.
Yan, Huan; Gong, Li-Yan; Huang, Wei; Peng, Yan-Li
2017-01-01
AIM To evaluate the possible differences in visual quality between small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) for myopia. METHODS A Meta-analysis was performed. Patients were from previously reported comparative studies treated with SMILE versus FS-LASIK. The PubMed, EMBASE, Cochrane, Web of Science and Chinese databases (i.e. WANFANG and CNKI) were searched in Nov. of 2016 using RevMan 5.1 version software. The differences in visual acuity, aberration and biomechanical effects within six months postoperatively were showed. Twenty-seven studies including 4223 eyes were included. RESULTS No significant differences were observed between SMILE and FS-LASIK in terms of the proportion of eyes that lost one or more lines of corrected distance visual acuity after surgery (P=0.14), the proportion of eyes achieving an uncorrected distance visual acuity of 20/20 or better (P=0.43), the final refractive spherical equivalent (P=0.89), the refractive spherical equivalent within ±1.00 diopter of the target values (P=0.80), vertical coma (P=0.45) and horizontal coma (P=0.06). Compared with the FS-LASIK group, total higher-order aberration (P<0.001) and spherical aberration (P<0.001) were higher and the decrease in corneal hysteresis (P=0.0005) and corneal resistance factor (P=0.02) were lower in the SMILE group. CONCLUSION SMILE and FS-LASIK are comparable in efficacy, safety and predictability for correcting myopia. However, the aberration in the SMILE group is superior to that in the FS-LASIK group, and the loss of biomechanical effects may occur less frequently after SMILE than after FS-LASIK. PMID:28944205
Bohac, Maja; Biscevic, Alma; Koncarevic, Mateja; Anticic, Marija; Gabric, Nikica; Patel, Sudi
2014-10-01
To compare functional outcomes of Wavelight Allegretto Eye-Q 400Hz and Schwind Amaris 750S excimer laser for astigmatism between 2 and 7 diopters(D). Prospective comparative non-randomized case series of 480 eyes assigned in two laser groups and further divided into myopic and mixed astigmatism subgroups. All treatments were centered on corneal vertex. One-year results were compared between the groups. Statistical analysis was performed using z-test. Both Allegretto and Amaris postoperative uncorrected distance visual acuity (UDVA) improved in comparison to preoperative corrected distance visual acuity (CDVA). The difference was significant in the Allegretto group for myopic astigmatism (p = 0.017). There was no difference in postoperative UDVA between lasers. Average sphere decreased in all groups for both lasers (p < 0.001) without difference in effectiveness of spherical correction between lasers for both groups. In Allegretto, average cylinder decreased from -3.30D to -0.55D in myopic astigmatism (p < 0.001) and from -3.84D to -0.85D in mixed astigmatism (p < 0.001). In Amaris average cylinder decreased from -3.21D to -0.43D in myopic astigmatism (p < 0.001) and from -3.66D to -0.58D in mixed astigmatism (p < 0.001). Amaris group had less residual astigmatism (myopic astigmatism p = 0.023, mixed astigmatism p < 0.001). Mean spherical aberration shifted from positive to negative in mixed astigmatism for both lasers. Both lasers are effective in terms of UDVA, CDVA, spherical correction, and preservation of high-order aberrations. However, Amaris was more effective in cylinder correction.
Mester, Ulrich; Vaterrodt, Thomas; Goes, Frank; Huetz, Werner; Neuhann, Irmingard; Schmickler, Stefanie; Szurman, Peter; Gekeler, Katrin
2014-10-01
This prospective multicenter study assessed personality characteristics that may influence patient satisfaction after implantation of multifocal intraocular lenses (MIOLs). One hundred eighty-three patients who underwent bilateral implantation of different MIOLs were enrolled. Uncorrected and corrected distance visual acuity for distance and near (ie, UDVA, UNVA, CDVA, and CNVA) were assessed preoperatively and 3 and 6 months after implantation. Before surgery, personality characteristics were evaluated using a questionnaire based on the NEO Personality Inventory Test and the Compulsiveness Inventory Test. At the 3- and 6-month postoperative visits, patients answered a questionnaire concerning overall satisfaction, need for spectacles at different distances, visual function at different distances and lighting conditions, photic phenomena, and ease of performing daily activities. Three months after surgery (n = 163), mean CDVA was 0.03 ± 0.09 logMAR, UDVA was 0.05 ± 0.09 logMAR, and UNVA was 0.04 ± 0.11 logMAR. At the 6-month visit (n = 131), mean CDVA was 0.02 ± 0.07 logMAR, UDVA was 0.06 ± 0.09 logMAR, and UNVA was 0.05 ± 0.01 logMAR. Most patients (82.2%) would opt for an MIOL again, 3.7% would not, and 14.1% were uncertain. Overall satisfaction with the procedure was correlated to low astigmatism, good visual function, low spectacle dependence, and less halos or glare. The personality characteristics of compulsive checking, orderliness, competence, and dutifulness were statistically significantly correlated to subjective disturbance by glare and halos. Postoperative patient satisfaction after MIOL implantation is correlated to visual performance, spectacle independence, and less photic phenomena. Personality characteristics have an impact on subjective disturbance by photic phenomena and thus are important for patient satisfaction. Copyright 2014, SLACK Incorporated.
The effect of multifocal soft contact lenses on peripheral refraction.
Kang, Pauline; Fan, Yvonne; Oh, Kelly; Trac, Kevin; Zhang, Frank; Swarbrick, Helen A
2013-07-01
To compare changes in peripheral refraction with single-vision (SV) and multifocal (MF) correction of distance central refraction with commercially available SV and MF soft contact lenses (SCLs) in young myopic adults. Thirty-four myopic adult subjects were fitted with Proclear Sphere and Proclear Multifocal SCLs to correct their manifest central refractive error. Central and peripheral refraction were measured with no lens wear and subsequently with the two different types of SCL correction. At baseline, refraction was myopic at all locations along the horizontal meridian. Peripheral refraction was relatively hyperopic compared with center at 30 and 35 degrees in the temporal visual field (VF) in low myopes, and at 30 and 35 degrees in the temporal VF, and 10, 30, and 35 degrees in the nasal VF in moderate myopes. Single-vision and MF distance correction with Proclear Sphere and Proclear Multifocal SCLs, respectively, caused a hyperopic shift in refraction at all locations in the horizontal VF. Compared with SV correction, MF SCL correction caused a significant relative myopic shift at all locations in the nasal VF in both low and moderate myopes and also at 35 degrees in the temporal VF in moderate myopes. Correction of central refractive error with SV and MF SCLs caused a hyperopic shift in both central and peripheral refraction at all positions in the horizontal meridian. Single-vision SCL correction caused the peripheral retina, which initially experienced absolute myopic defocus at baseline with no correction to experience an absolute hyperopic defocus. Multifocal SCL correction resulted in a relative myopic shift in peripheral refraction compared with SV SCL correction. This myopic shift may explain recent reports of reduced myopia progression rates with MF SCL correction.
Nowak, Michal S.; Smigielski, Janusz
2015-01-01
Abstract To investigate the prevalence and causes of visual impairment and blindness in a sample of Polish older adults. The study was designed in a cross-sectional and observational manner. Data concerning the vision status were assessed in 2214 eyes from 1107 subjects of European Caucasian origin; most of whom live in the city of Lodz, in central Poland. Visual impairment was defined as distance visual acuity <20/40 in the worse-seeing eye. Low vision was defined as best-corrected visual acuity (BCVA) <20/40 but >20/200 in better-seeing eye, and blindness was defined as BCVA ≤20/200 in both eyes (United States criteria). Visual impairment was found in 27.5% subjects in the worse-seeing eye. Multiple regression analysis showed that increasing age (OR 0.98, 95% CI 0.97–0.99) and female gender (OR 1.47, 95% CI 1.11–1.93) were independent risk factors. No association was found between visual impairment and socioeconomic status of subjects. Noncorrectable visual impairment was found in 7.0% of subjects, including 5.2% of subjects with unilateral and 1.8% of subjects with bilateral visual impairment. Low vision and blindness accounted for 1.3% and 0.5%, respectively, and were only associated with older age (OR 1.05, 95% CI 1.02–1.10). Retinal diseases represented the major cause of noncorrectable visual impairment and accounted for more than half of causes of blindness. Provision of appropriate refractive correction improves visual acuity in 75% subjects presenting with visual impairment. Retinal diseases are a major cause of noncorrectable visual impairment and blindness in this older population. PMID:25654398
Nowak, Michal S; Smigielski, Janusz
2015-02-01
To investigate the prevalence and causes of visual impairment and blindness in a sample of Polish older adults. The study was designed in a cross-sectional and observational manner. Data concerning the vision status were assessed in 2214 eyes from 1107 subjects of European Caucasian origin; most of whom live in the city of Lodz, in central Poland. Visual impairment was defined as distance visual acuity <20/40 in the worse-seeing eye. Low vision was defined as best-corrected visual acuity (BCVA) <20/40 but >20/200 in better-seeing eye, and blindness was defined as BCVA ≤20/200 in both eyes (United States criteria). Visual impairment was found in 27.5% subjects in the worse-seeing eye. Multiple regression analysis showed that increasing age (OR 0.98, 95% CI 0.97-0.99) and female gender (OR 1.47, 95% CI 1.11-1.93) were independent risk factors. No association was found between visual impairment and socioeconomic status of subjects. Noncorrectable visual impairment was found in 7.0% of subjects, including 5.2% of subjects with unilateral and 1.8% of subjects with bilateral visual impairment. Low vision and blindness accounted for 1.3% and 0.5%, respectively, and were only associated with older age (OR 1.05, 95% CI 1.02-1.10). Retinal diseases represented the major cause of noncorrectable visual impairment and accounted for more than half of causes of blindness. Provision of appropriate refractive correction improves visual acuity in 75% subjects presenting with visual impairment. Retinal diseases are a major cause of noncorrectable visual impairment and blindness in this older population.
Toying with the moon illusion.
Lockhead, G R; Wolbarsht, M L
1991-08-20
We propose that the correct interpretation of the moon illusion is that the zenith moon appears small, not that the horizon moon appears large. This illusion is caused by the visual gap between the observer and the overhead moon. Because of the gap, the observer has no or little optical information about the distance of the moon. This results in empty field myopia where the moon is neurally, although not necessarily cognitively, processed as being at about arm's length. When the moon is seen on the horizon, there usually is optical information about distance. That results in reduced accommodation, and so the moon is processed as at a greater distance. Consistent with the size-distance-invariance hypothesis, the moon is then judged as large. This is a specific example of the more general fact that all distant objects appear small in the absence of a stimulus for accommodation to be distant. This outcome produces the toy illusion.
Mapping the Space of Genomic Signatures
Kari, Lila; Hill, Kathleen A.; Sayem, Abu S.; Karamichalis, Rallis; Bryans, Nathaniel; Davis, Katelyn; Dattani, Nikesh S.
2015-01-01
We propose a computational method to measure and visualize interrelationships among any number of DNA sequences allowing, for example, the examination of hundreds or thousands of complete mitochondrial genomes. An "image distance" is computed for each pair of graphical representations of DNA sequences, and the distances are visualized as a Molecular Distance Map: Each point on the map represents a DNA sequence, and the spatial proximity between any two points reflects the degree of structural similarity between the corresponding sequences. The graphical representation of DNA sequences utilized, Chaos Game Representation (CGR), is genome- and species-specific and can thus act as a genomic signature. Consequently, Molecular Distance Maps could inform species identification, taxonomic classifications and, to a certain extent, evolutionary history. The image distance employed, Structural Dissimilarity Index (DSSIM), implicitly compares the occurrences of oligomers of length up to k (herein k = 9) in DNA sequences. We computed DSSIM distances for more than 5 million pairs of complete mitochondrial genomes, and used Multi-Dimensional Scaling (MDS) to obtain Molecular Distance Maps that visually display the sequence relatedness in various subsets, at different taxonomic levels. This general-purpose method does not require DNA sequence alignment and can thus be used to compare similar or vastly different DNA sequences, genomic or computer-generated, of the same or different lengths. We illustrate potential uses of this approach by applying it to several taxonomic subsets: phylum Vertebrata, (super)kingdom Protista, classes Amphibia-Insecta-Mammalia, class Amphibia, and order Primates. This analysis of an extensive dataset confirms that the oligomer composition of full mtDNA sequences can be a source of taxonomic information. This method also correctly finds the mtDNA sequences most closely related to that of the anatomically modern human (the Neanderthal, the Denisovan, and the chimp), and that the sequence most different from it in this dataset belongs to a cucumber. PMID:26000734
Surgical technique for management of isolated lenticular coloboma with high corneal astigmatism.
Singh, Simar Rajan; Yangzes, Sonam; Gupta, Rohit; Ram, Jagat
2018-04-01
We describe a surgical technique for the correction of isolated congenital lenticular coloboma associated with high corneal astigmatism. Transscleral fixation of the capsular bag with a single eyelet Cionni capsular tension ring was followed by in-the-bag implantation of a toric intraocular lens (IOL). This lead to complete correction of the lenticular defect and perfect alignment of the toric lens. In this case, the child attained an unaided distance visual acuity of 20/30 following amblyopia therapy and a well-aligned toric IOL at 12 months of follow-up. This technique can be used in cases with concomitant lenticular coloboma and significant corneal astigmatism.
Surgical technique for management of isolated lenticular coloboma with high corneal astigmatism
Singh, Simar Rajan; Yangzes, Sonam; Gupta, Rohit; Ram, Jagat
2018-01-01
We describe a surgical technique for the correction of isolated congenital lenticular coloboma associated with high corneal astigmatism. Transscleral fixation of the capsular bag with a single eyelet Cionni capsular tension ring was followed by in-the-bag implantation of a toric intraocular lens (IOL). This lead to complete correction of the lenticular defect and perfect alignment of the toric lens. In this case, the child attained an unaided distance visual acuity of 20/30 following amblyopia therapy and a well-aligned toric IOL at 12 months of follow-up. This technique can be used in cases with concomitant lenticular coloboma and significant corneal astigmatism. PMID:29582820
Kong, Yong-Ku; Lee, Inseok; Jung, Myung-Chul; Song, Young-Woong
2011-05-01
This study evaluated the effects of age (20s and 60s), viewing distance (50 cm, 200 cm), display type (paper, monitor), font type (Gothic, Ming), colour contrast (black letters on white background, white letters on black background) and number of syllables (one, two) on the legibility of Korean characters by using the four legibility measures (minimum letter size for 100% correctness, maximum letter size for 0% correctness, minimum letter size for the least discomfort and maximum letter size for the most discomfort). Ten subjects in each age group read the four letters presented on a slide (letter size varied from 80 pt to 2 pt). Subjects also subjectively rated the reading discomfort of the letters on a 4-point scale (1 = no discomfort, 4 = most discomfort). According to the ANOVA procedure, age, viewing distance and font type significantly affected the four dependent variables (p < 0.05), while the main effect of colour contrast was not statistically significant for any measures. Two-syllable letters had smaller letters than one-syllable letters in the two correctness measures. The younger group could see letter sizes two times smaller than the old group could and the viewing distance of 50 cm showed letters about three times smaller than those at a 200 cm viewing distance. The Gothic fonts were smaller than the Ming fonts. Monitors were smaller than paper for correctness and maximum letter size for the most discomfort. From a comparison of the results for correctness and discomfort, people generally preferred larger letter sizes to those that they could read. The findings of this study may provide basic information for setting a global standard of letter size or font type to improve the legibility of characters written in Korean. STATEMENT OF RELEVANCE: Results obtained in this study will provide basic information and guidelines for setting standards of letter size and font type to improve the legibility of characters written in Korean. Also, the results might offer useful information for people who are working on design of visual displays.
Hashemi, Hassan; Miraftab, Mohammad; Ghaffari, Reza; Asgari, Soheila
2016-11-01
To compare the results of femtosecond-assisted laser in situ keratomileusis (femto-LASIK) and photorefractive keratectomy with mitomycin C (PRK-MMC) for the correction of myopia more than 7.0 diopters (D). In this comparative nonrandomized trial, 60 eyes (30 eyes in each group) were enrolled. Patients were tested for uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, ocular and corneal aberrations, and contrast sensitivity (CS) before surgery and at 3 and 6 months postoperatively. Mean preoperative myopia was -8.65±1.51 and -8.04±1.70 D in the femto-LASIK and PRK-MMC groups, respectively (P=0.149). Intergroup differences in baseline indices were not statistically significant. At 6 months after surgery, UDVA showed an improving trend, but it was better in the femto-LASIK group (P=0.026). CDVA in the two groups remained similarly unchanged (P=0.170). For the femto-LASIK and PRK-MMC groups, the safety indices were 1.01±0.05 and 1.01±0.14 (P=0.949), respectively, and the efficacy indices were 0.99±0.07 and 0.93±0.22 (P=0.192), respectively. Comparing CS, only CS18 showed a significantly greater decrease in the femto-LASIK group compared with the PRK-MMC group (P=0.016). Intergroup differences were not statistically significant in other spatial frequencies. Changes in the ocular and corneal higher order aberrations were not statistically different between the two groups except ocular coma, which increased in the femto-LASIK group (P=0.041). Femto-LASIK improves UDVA better than PRK-MMC in high myopia. However, because of increased coma, the quality of vision is reduced. In other words, visual acuity outcome is better with femto-LASIK and visual quality outcome is better with PRK-MMC.
Shalash, Riad B; Elshazly, Malak I; Salama, Marwa M
2015-10-01
To evaluate a new technique combining intrastromal astigmatic keratotomy (AK) with a laser in situ keratomileusis (LASIK) flap followed by excimer laser photoablation to correct post-penetrating keratoplasty (PKP) high astigmatism and ametropia. Kasr El Aini Hospital, Cairo University, Cairo, Egypt. Prospective interventional uncontrolled case series. Patients with post-PKP high astigmatism and ametropia had paired intrastromal AK with LASIK flap using the M2 microkeratome followed 2 to 3 months later by excimer laser photoablation. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), mean refractive spherical equivalent (SE), and mean cylinder after each step and at the 1-year follow-up. The study comprised 20 eyes (20 patients). All parameters were significantly improved in all patients by the last follow-up visit. The mean UDVA improved from 1.07 logMAR ± 0.2 (SD) preoperatively to 0.23 ± 0.18 logMAR (P < .001), the mean CDVA improved from 0.79 ± 0.18 logMAR to 0.12 ± 0.12 logMAR (P < .001), the mean refractive SE improved from -5.04 ± 2.62 diopters (D) to -1.47 ± 1.32 D (P = .001), and the mean cylinder reduced from -5.39 ± 0.98 D to -1.05 ± 0.71 D (P < .001). The mean correction index was 0.84 ± 0.10, and the mean flattening index was 0.83 ± 0.10. Thirty-five percent of cases developed microperforations, and 15% developed epithelial ingrowth. This combined approach allowed for the correction of high astigmatism and ametropia following PKP; however, epithelial ingrowth requiring intervention is a complication to be considered. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Debois, A; Nochez, Y; Bezo, C; Bellicaud, D; Pisella, P-J
2012-10-01
To study efficacy and predictability of toric IOL implantation for correction of preoperative corneal astigmatism by analysing spherocylindrical refractive precision and objective quality of vision. Prospective study of 13 eyes undergoing micro-incisional cataract surgery through a 1.8mm corneal incision with toric IOL implantation (Lentis L313T(®), Oculentis) to treat over one D of preoperative corneal astigmatism. Preoperative evaluation included keratometry, subjective refraction, and total and corneal aberrometry (KR-1(®), Topcon). Six months postoperatively, measurements included slit lamp photography, documenting IOL rotation, tilt or decentration, uncorrected visual acuity, best-corrected visual acuity and objective quality of vision measurement (OQAS(®) Visiometrics, Spain). Postoperatively, mean uncorrected distance visual acuity was 8.33/10 ± 1.91 (0.09 ± 0.11 LogMar). Mean postoperative refractive sphere was 0.13 ± 0.73 diopters. Mean refractive astigmatism was -0.66 ± 0.56 diopters with corneal astigmatism of 2.17 ± 0.68 diopters. Mean IOL rotation was 4.4° ± 3.6° (range 0° to 10°). Mean rotation of this IOL at 6 months was less than 5°, demonstrating stability of the optic within the capsular bag. Objective quality of vision measurements were consistent with subjective uncorrected visual acuity. Implantation of the L313T(®) IOL is safe and effective for correction of corneal astigmatism in 1.8mm micro-incisional cataract surgery. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Gatzioufas, Zisis; Panos, Georgios D; Elalfy, Mohamed; Khine, Aye; Hamada, Samer; Lake, Damian; Kozeis, Nikos; Balidis, Miltos
2018-03-01
To investigate the potential impact of cone eccentricity on visual outcomes after Keraring (Mediphacos, Belo Horizonte, Brazil) implantation for keratoconus. Nineteen eyes from 19 patients with keratoconus who underwent femtosecond laser-assisted Keraring implantation for keratoconus were included in this retrospective study. Uncorrected visual acuity (UDVA), corrected visual acuity (CDVA), keratometric readings, central corneal thickness, maximum keratometric distance from corneal apex (DKmax), corneal thinnest point from corneal apex (DTh), and coma were evaluated preoperatively and 6 months after the Keraring implantation. DKmax and DTh were used as metrics reflecting the eccentricity of the cone. UDVA, CDVA, keratometric readings, and coma improved at 6 months postoperatively. However, there was no correlation between DKmax or DTh and visual outcomes at 6 months postoperatively. The data did not show any impact of the cone eccentricity on visual outcomes after Keraring implantation for keratoconus at 6 months postoperatively. [J Refract Surg. 2018;34(3):196-200.]. Copyright 2018, SLACK Incorporated.
Ganesh, Sri; Brar, Sheetal
2015-10-01
To evaluate the initial outcomes of femtosecond intrastromal lenticular implantation (FILI) combined with accelerated collagen cross-linking in patients with progressive keratoconus. In this interventional, prospective, exploratory case series, patients with progressive keratoconus and contact lens intolerance were included. All eyes underwent femtosecond laser-enabled placement of stromal donor tissue and simultaneous accelerated collagen cross-linking. Follow-up of patients was conducted for a mean period of 190 ± 13 days (range, 177-193 days). Six eyes from 6 patients were included in the study. Based on values before and 6 months after the procedure, clinical improvement was noted in uncorrected distance visual acuity (1.06 ± 0.48 logMAR vs. 0.38 ± 0.27 logMAR), corrected distance visual acuity (0.51 ± 0.20 logMAR vs. 0.20 ± 0.24 logMAR), and manifest spherical equivalent (-3.47 ± 1.15 D vs. -1.77 ± 1.7 D). There was flattening of mean keratometry in 3-mm and 5-mm zones by 3.42 ± 2.09 D and 1.70 ± 1.31 D, respectively. Mean pachymetry in the central and midperipheral zones increased by 18.3 ± 7.3 μm and 33.0 ± 8.8 μm, respectively. All eyes had reduction in higher-order aberrations, specifically coma. No eye lost lines of corrected distance visual acuity. No adverse events such as haze, infection, or allogeneic graft rejection were observed. Initial experience with this small number of eyes suggests that the combination of tissue addition and accelerated collagen cross-linking may be a feasible option for low to moderate keratoconus. A larger cohort and longer follow-up are required to validate our results and establish long-term safety and efficacy of the procedure.
2017-01-01
Purpose. To report visual performance and quality of life after implantation of a bifocal diffractive multifocal intraocular lens (MIOL) in postmyopic laser in situ keratomileusis (LASIK) patients. Methods. Prospective, observational case series. Patients with prior myopic LASIK who had implantation of Tecnis ZMA00/ZMB00 MIOL (Abbott Medical Optics) at Hong Kong Sanatorium and Hospital were included. Postoperative examinations included monocular and binocular distance, intermediate and near visual acuity (VA), and contrast sensitivity; visual symptoms (0–5); satisfaction (1–5); spectacle independence rate; and quality of life. Results. Twenty-three patients (27 eyes) were included. No intraoperative complications developed. Mean monocular uncorrected VA at distance, intermediate, and near were 0.13 ± 0.15 (standard deviation), 0.22 ± 0.15, and 0.16 ± 0.15, respectively. Corresponding mean values for binocular uncorrected VA were 0.00 ± 0.10, 0.08 ± 0.13, and 0.13 ± 0.10, respectively. No eyes lost >1 line of corrected distance VA. Contrast sensitivity at different spatial frequencies between operated and unoperated eyes did not differ significantly (all P > 0.05). Mean score for halos, night glare, starbursts, and satisfaction were 1.46 ± 1.62, 1.85 ± 1.69, 0.78 ± 1.31, and 3.50 ± 1.02, respectively. Eighteen patients (78%) reported complete spectacle independence. Mean composite score of the quality-of-life questionnaire was 90.31 ± 8.50 out of 100. Conclusions. Implantation of the MIOL after myopic LASIK was safe and achieved good visual performance. PMID:28133543
Chang, John S M; Ng, Jack C M; Chan, Vincent K C; Law, Antony K P
2017-01-01
Purpose . To report visual performance and quality of life after implantation of a bifocal diffractive multifocal intraocular lens (MIOL) in postmyopic laser in situ keratomileusis (LASIK) patients. Methods . Prospective, observational case series. Patients with prior myopic LASIK who had implantation of Tecnis ZMA00/ZMB00 MIOL (Abbott Medical Optics) at Hong Kong Sanatorium and Hospital were included. Postoperative examinations included monocular and binocular distance, intermediate and near visual acuity (VA), and contrast sensitivity; visual symptoms (0-5); satisfaction (1-5); spectacle independence rate; and quality of life. Results . Twenty-three patients (27 eyes) were included. No intraoperative complications developed. Mean monocular uncorrected VA at distance, intermediate, and near were 0.13 ± 0.15 (standard deviation), 0.22 ± 0.15, and 0.16 ± 0.15, respectively. Corresponding mean values for binocular uncorrected VA were 0.00 ± 0.10, 0.08 ± 0.13, and 0.13 ± 0.10, respectively. No eyes lost >1 line of corrected distance VA. Contrast sensitivity at different spatial frequencies between operated and unoperated eyes did not differ significantly (all P > 0.05). Mean score for halos, night glare, starbursts, and satisfaction were 1.46 ± 1.62, 1.85 ± 1.69, 0.78 ± 1.31, and 3.50 ± 1.02, respectively. Eighteen patients (78%) reported complete spectacle independence. Mean composite score of the quality-of-life questionnaire was 90.31 ± 8.50 out of 100. Conclusions . Implantation of the MIOL after myopic LASIK was safe and achieved good visual performance.
Fadlallah, Ali; Dirani, Ali; Chelala, Elias; Antonios, Rafic; Cherfan, George; Jarade, Elias
2014-10-01
To evaluate the safety and clinical outcome of combined non-topography-guided photorefractive keratectomy (PRK) and corneal collagen cross-linking (CXL) for the treatment of mild refractive errors in patients with early stage keratoconus. A retrospective, nonrandomized study of patients with early stage keratoconus (stage 1 or 2) who underwent simultaneous non-topography-guided PRK and CXL. All patients had at least 2 years of follow-up. Data were collected preoperatively and postoperatively at the 6-month, 1-year, and 2-year follow-up visit after combined non-topography-guided PRK and CXL. Seventy-nine patients (140 eyes) were included in the study. Combined non-topography-guided PRK and CXL induced a significant improvement in both visual acuity and refraction. Uncorrected distance visual acuity significantly improved from 0.39 ± 0.22 logMAR before combined non-topography-guided PRK and CXL to 0.12 ± 0.14 logMAR at the last follow-up visit (P <.001) and corrected distance visual acuity remained stable (0.035 ± 0.062 logMAR preoperatively vs 0.036 ± 0.058 logMAR postoperatively, P =.79). The mean spherical equivalent decreased from -1.78 ± 1.43 to -0.42 ± 0.60 diopters (D) (P <.001), and the mean cylinder decreased from 1.47 ± 1.10 to 0.83 ± 0.55 D (P <.001). At the last follow-up visit mean keratometry flat was 43.30 ± 1.75 vs 45.62 ± 1.72 D preoperatively (P = .03) and mean keratometry steep was 44.39 ± 3.14 vs 46.53 ± 2.13 D preoperatively (P = .02). Mean central corneal thickness decreased from 501.74 ± 13.11 to 475.93 ± 12.25 µm following combined non-topography-guided PRK and CXL (P < .001). No intraoperative complications occurred. Four eyes developed mild haze that responded well to a short course of topical steroids. No eye developed infectious keratitis. Combined non-topography-guided PRK and CXL is an effective and safe option for correcting mild refractive error and improving visual acuity in patients with early stable keratoconus. Copyright 2014, SLACK Incorporated.
Kolarik, Andrew J; Cirstea, Silvia; Pardhan, Shahina
2013-02-01
Totally blind listeners often demonstrate better than normal capabilities when performing spatial hearing tasks. Accurate representation of three-dimensional auditory space requires the processing of available distance information between the listener and the sound source; however, auditory distance cues vary greatly depending upon the acoustic properties of the environment, and it is not known which distance cues are important to totally blind listeners. Our data show that totally blind listeners display better performance compared to sighted age-matched controls for distance discrimination tasks in anechoic and reverberant virtual rooms simulated using a room-image procedure. Totally blind listeners use two major auditory distance cues to stationary sound sources, level and direct-to-reverberant ratio, more effectively than sighted controls for many of the virtual distances tested. These results show that significant compensation among totally blind listeners for virtual auditory spatial distance leads to benefits across a range of simulated acoustic environments. No significant differences in performance were observed between listeners with partial non-correctable visual losses and sighted controls, suggesting that sensory compensation for virtual distance does not occur for listeners with partial vision loss.
Snyder, L H; King, W M
1992-04-01
1. The vestibuloocular reflex (VOR) stabilizes images on the retina against movements of the head in space. Viewing distance, target eccentricity, and location of the axis of rotation may influence VOR responses because rotation of the head about most axes in space rotates and translates the eyes relative to visual targets. To study the VOR response to combined rotation and translation, monkeys were placed on a rate table and rotated briefly in the dark about a vertical axis that was located in front of or behind the eyes. The monkeys fixated a near or far visual target that was extinguished before the rotation. Eye movements were recorded from both eyes by the use of the search coil technique. 2. Peak eye velocity evoked by the VOR was linearly related to vergence angle for any axis of rotation. The percent change in the VOR with near target viewing relative to far target viewing at a vergence angle of 20 degrees was linearly related to the location of the axis of rotation. Axes located behind the eyes produced positive changes in VOR amplitude, and axes located in front of the eyes produced negative changes in VOR amplitude. An axis of rotation located in the coronal plane containing the centers of rotation of the eyes produced no modification of VOR amplitude. For any axis, the VOR compensated for approximately 90% of the translation of the eye relative to near targets. 3. The initial VOR response was not correct in magnitude but was refined by a series of three temporally delayed corrections of increasing complexity. The earliest VOR-evoked eye movement (10-20 ms after rotation onset) was independent of viewing distance and rotational axis location. In the next 100 ms, eye speed appeared to be sequentially modified three times: within 20 ms by viewing distance; within 30 ms by otolith translation; and within 100 ms by eye translation relative to the visual target. 4. These data suggest a formal model of the VOR consisting of four channels. Channel 1 conveys an unmodified head rotation signal with a pure delay of 10 ms. Channel 2 conveys an angular head velocity signal, modified by viewing distance with a pure delay of 20 ms, but invariant with respect to the location of the axis of rotation. Channel 3 conveys a linear head velocity signal, dependent on the location of the axis of rotation, that is modified by viewing distance with a pure delay of 30 ms.(ABSTRACT TRUNCATED AT 400 WORDS)
de Ortueta, Diego; Arba-Mosquera, Sam
2017-03-10
To investigate refractive outcomes and induction of corneal higher order aberrations (HOA) in eyes that underwent laser-assisted in situ keratomileusis (LASIK) for high hyperopia correction using an aberration neutral profile with corneal vertex centration and asymmetric offset. A total of 24 consecutive patients (38 eyes) who underwent LASIK by one surgeon using AMARIS 750S excimer laser and a Carriazo-Pendular microkeratome for flap creation were retrospectively analyzed. Eyes targeted for plano and with correction in the maximum hyperopic meridian strictly higher than +4D were included in the retrospective analysis. Patients were reviewed at 1, 3, and 6 months postoperatively. Postoperative monocular corrected distance visual acuity (CDVA) and uncorrected distance visual acuity (UDVA), manifest refraction, and corneal wavefront aberrations were compared with respective preoperative metrics. Mean preoperative spherical equivalent and refractive astigmatism was +4.07 ± 0.90 D and 1.37 ± 1.26 D, respectively, reducing to +0.28 ± 0.58D (p<0.0001) and 0.49 ± 0.47 D (p = 0.0001) at the last postoperative visit. Six months postoperatively, 78% of eyes achieved a UDVA of 20/25 or better. No eye lost more than 2 Snellen lines of CDVA at any follow-up. There was a statistically significant induction of vertical trefoil (+0.104 ± 0.299 µm, p<0.05), vertical coma (-0.181 ± 0.463 µm, p<0.01), horizontal coma (+0.198 ± 0.663 µm, p<0.05), spherical aberration (-0.324 ± 0.281 µm, p<0.0001), secondary vertical trefoil (+0.018 ± 0.044 µm, p<0.01), and secondary horizontal coma (+0.026 ± 0.083 µm, p<0.05). Laser-assisted in situ keratomileusis for high hyperopia using corneal vertex centration with asymmetric offset results in significant improvement in refraction and visual acuity although affected by significant induction of some higher order aberrations.
Age-Related Eye Diseases and Visual Impairment Among U.S. Adults
Chou, Chiu-Fang; Cotch, Mary Frances; Vitale, Susan; Zhang, Xinzhi; Klein, Ronald; Friedman, David S.; Klein, Barbara E.K.; Saaddine, Jinan B.
2014-01-01
Background Visual impairment is a common health-related disability in the U.S. The association between clinical measurements of age-related eye diseases and visual impairment in data from a national survey has not been reported. Purpose To examine common eye conditions and other correlates associated with visual impairment in the U.S. Methods Data from the 2005–2008 National Health and Nutrition Examination Survey of 5222 Americans aged ≥40 years were analyzed in 2012 for visual impairment (presenting distance visual acuity worse than 20/40 in the better-seeing eye), and visual impairment not due to refractive error (distance visual acuity worse than 20/40 after refraction). Diabetic retinopathy (DR) and age-related macular degeneration (AMD) were assessed from retinal fundus images; glaucoma was assessed from two successive frequency-doubling tests and a cup-to-disc ratio measurement. Results Prevalence of visual impairment and of visual impairment not due to refractive error was 7.5% (95% CI=6.9%, 8.1%) and 2.0% (1.7%, 2.3%), respectively. The prevalence of visual impairment not due to refractive error was significantly higher among people with AMD (2.2%) compared to those without AMD (0.8%), or with DR (3.5%) compared to those without DR (1.2%). Independent predictive factors of visual impairment not due to refractive error were AMD (OR=4.52, 95% CI=2.50, 8.17); increasing age (OR=1.09 per year, 95% CI=1.06, 1.13); and less than a high school education (OR=2.99, 95% CI=1.18, 7.55). Conclusions Visual impairment is a public health problem in the U.S. Visual impairment in two thirds of adults could be eliminated with refractive correction. Screening of the older population may identify adults at increased risk of visual impairment due to eye diseases. PMID:23790986
Abdelkader, Almamoun; Kaufman, Herbert E
2016-01-01
To test and compare in a masked fashion the efficacy of using a parasympathomimetic drug (3% carbachol) and an alpha-2 agonist (0.2% brimonidine) in both combined and separate forms to create optically beneficial miosis to pharmacologically improve vision in presbyopia. A prospective, double-masked, randomized, controlled clinical trial was conducted. Ten naturally emmetropic and presbyopic subjects between 42 and 58 years old with uncorrected distance visual acuity of at least 20/20 in both eyes without additional ocular pathology were eligible for inclusion. All subjects received 3% carbachol and 0.2% brimonidine in both combined and separate forms, 3% carbachol alone and 0.2% brimonidine (control) alone in their non-dominant eye in a crossover manner with one week washout between tests. The subjects' pupil sizes and both near and distance visual acuities will be evaluated pre- and post-treatment at 1, 2, 4, and 8 h, by a masked examiner at the same room illumination. Statistically significant improvement in mean near visual acuity (NVA) was achieved in all subjects who received combined 3% carbachol and 0.2% brimonidine in the same formula compared with those who received separate forms or carbachol alone or brimonidine alone ( P < 0.0001). Based on the data, the combined solution demonstrated greater efficacy than the other solutions that were tested. Improving the depth of focus by making the pupil small caused statistically significant improvement in near visual acuity, with no change in binocular distance vision. ACTRN12616001565437. Registered 11 November 2016.
Ganesh, Sri; Brar, Sheetal; Pawar, Archana
2017-01-01
Purpose To compare toric implantable collamer lens (T-ICL), femto-LASIK, and ReLEx SMILE for the treatment of low to moderate myopic astigmatism in terms of long-term visual and refractive outcomes and predictability of astigmatic correction. Materials and methods The study included 30 eyes from 30 patients between the age groups of 21 and 40 years, undergoing bilateral surgery with any of the three procedures – T-ICL, femto-LASIK, or ReLEx SMILE – for correction of myopic astigmatism within the range of −3 to −8 D spherical equivalent (SE), with a minimum astigmatism of −0.75 D. Patients were followed up at day 1, 1 month, 6 months, and 1 year. Results At 1 year, the mean cylinder reduced to −0.21±0.28, −0.17±0.36, and −0.22±0.28 D in the T-ICL, femto-LASIK, and ReLEx SMILE group, respectively. The predictability of astigmatism correction was comparable, with no statistically significant difference between the 3 groups (P>0.05). A total of 97% of eyes in ReLEx SMILE achieved a uncorrected distance visual acuity of 20/20 or better, compared to T-ICL (93%) and FS-LASIK (90%). However, gain in lines of corrected distant visual acuity (CDVA) was maximum in T-ICL group (60%). Four eyes in the femto-LASIK group had loss of CDVA by one line. Three eyes required exchange due to high vault and rotation of the T-ICL, which did not affect the final outcome. Conclusion All 3 modalities were effective for myopic astigmatism at the end of 1 year. Quality of vision and patient satisfaction with T-ICL and ReLEx SMILE were similar and better than FS-LASIK. However, slight chances of postoperative rotation and exchange exist with T-ICL, which warrant thorough preoperative planning. PMID:28740361
NASA Astrophysics Data System (ADS)
Viertler, Franz; Hajek, Manfred
2015-05-01
To overcome the challenge of helicopter flight in degraded visual environments, current research considers headmounted displays with 3D-conformal (scene-linked) visual cues as most promising display technology. For pilot-in-theloop simulations with HMDs, a highly accurate registration of the augmented visual system is required. In rotorcraft flight simulators the outside visual cues are usually provided by a dome projection system, since a wide field-of-view (e.g. horizontally > 200° and vertically > 80°) is required, which can hardly be achieved with collimated viewing systems. But optical see-through HMDs do mostly not have an equivalent focus compared to the distance of the pilot's eye-point position to the curved screen, which is also dependant on head motion. Hence, a dynamic vergence correction has been implemented to avoid binocular disparity. In addition, the parallax error induced by even small translational head motions is corrected with a head-tracking system to be adjusted onto the projected screen. For this purpose, two options are presented. The correction can be achieved by rendering the view with yaw and pitch offset angles dependent on the deviating head position from the design eye-point of the spherical projection system. Furthermore, it can be solved by implementing a dynamic eye-point in the multi-channel projection system for the outside visual cues. Both options have been investigated for the integration of a binocular HMD into the Rotorcraft Simulation Environment (ROSIE) at the Technische Universitaet Muenchen. Pros and cons of both possibilities with regard on integration issues and usability in flight simulations will be discussed.
Relationship Between Binocular Summation and Stereoacuity After Strabismus Surgery
KATTAN, Jaffer M.; VELEZ, Federico G.; DEMER, Joseph L.
2016-01-01
Purpose To describe the relationship between binocular summation and stereoacuity after strabismus surgery. Design Prospective Case Series Methods Setting Stein Eye institute, University of California Los Angeles Patient Population Pediatric strabismic patients who underwent strabismus surgery between 2010 and 2015. Observation Procedures Early Treatment Diabetic Retinopathy Study visual acuity, Sloan low-contrast acuity (LCA, 2.5% and 1.25%) and Randot stereoacuity 2 months following surgical correction of strabismus. Main Outcome Measures The relationship between binocular summation, calculated as the difference between the binocular visual acuity score and that of the better eye, and stereoacuity. Results A total of 130 post-operative strabismic patients were studied. The relationship between binocular summation and stereoacuity was studied by Spearman correlation. There were significant correlations between BiS for 2.5% LCA with near and distance stereoacuity (p=0.006 and 0.009). BiS for 1.25% LCA was also significantly correlated with near stereoacuity (p=0.04). Near stereoacuity and BiS for 2.5% and 1.25% LCA were significantly dependent (Pearson Chi Squared, p=0.006 and p=0.026). Patients with stereoacuity demonstrated significantly more BiS in 2.5% LCA of 2.7 (p=0.022) and 3.1 (p=0.014) letters than did those without near or distance stereoacuity, respectively. Conclusions These findings demonstrate that stereopsis and binocular summation are significantly correlated in patients who have undergone surgical correction of strabismus. PMID:26921805
The effect of monitor raster latency on VEPs, ERPs and Brain-Computer Interface performance.
Nagel, Sebastian; Dreher, Werner; Rosenstiel, Wolfgang; Spüler, Martin
2018-02-01
Visual neuroscience experiments and Brain-Computer Interface (BCI) control often require strict timings in a millisecond scale. As most experiments are performed using a personal computer (PC), the latencies that are introduced by the setup should be taken into account and be corrected. As a standard computer monitor uses a rastering to update each line of the image sequentially, this causes a monitor raster latency which depends on the position, on the monitor and the refresh rate. We technically measured the raster latencies of different monitors and present the effects on visual evoked potentials (VEPs) and event-related potentials (ERPs). Additionally we present a method for correcting the monitor raster latency and analyzed the performance difference of a code-modulated VEP BCI speller by correcting the latency. There are currently no other methods validating the effects of monitor raster latency on VEPs and ERPs. The timings of VEPs and ERPs are directly affected by the raster latency. Furthermore, correcting the raster latency resulted in a significant reduction of the target prediction error from 7.98% to 4.61% and also in a more reliable classification of targets by significantly increasing the distance between the most probable and the second most probable target by 18.23%. The monitor raster latency affects the timings of VEPs and ERPs, and correcting resulted in a significant error reduction of 42.23%. It is recommend to correct the raster latency for an increased BCI performance and methodical correctness. Copyright © 2017 Elsevier B.V. All rights reserved.
Escandón-García, Santiago; Ribeiro, Filomena J.; McAlinden, Colm
2018-01-01
Purpose To compare the through-focus visual performance in a clinical population of pseudophakic patients implanted with two new trifocal intraocular lenses (IOLs) and one extended depth of focus IOL. Methods Prospective, nonrandomized, examiner-masked case series. Twenty-three patients received the FineVision® and seven patients received the PanOptix™ trifocal IOLs. Fifteen patients received the Symfony extended depth of focus IOL. Mean age of patients was 63 ± 8 years. Through-focus visual acuity was measured from –3.00 to +1.00 D vergences. Contrast sensitivity was measured with and without a source of glare. Light disturbances were evaluated with the Light Distortion Analyzer. Results Though-focus evaluation showed that trifocal IOLs performed significantly better at near distance (33 and 40 cm), and extended depth of focus performed significantly better at intermediate distance (1.0 m). Contrast sensitivity function with glare and dysphotopsia was similar between the three IOLs and subjective response to questionnaire showed a significantly higher score (worse performance) for the extended depth of focus IOL compared to both trifocal IOLs in the bothersome subscale (p < 0.05). Conclusions Trifocal IOLs grant better performance at near distance while extended depth of focus IOL performs better at intermediate distance. Objective dysphotopsia measured with the Light Distortion Analyzer is not reduced in extended depth of focus IOL compared to trifocal IOLs. PMID:29651343
Lundström, Mats; Goh, Pik-Pin; Henry, Ype; Salowi, Mohamad A; Barry, Peter; Manning, Sonia; Rosen, Paul; Stenevi, Ulf
2015-01-01
The aim of this study was to describe changes over time in the indications and outcomes of cataract surgery and to discuss optimal timing for the surgery. Database study. Patients who had undergone cataract extraction in the Netherlands, Sweden, or Malaysia from 2008 through 2012. We analyzed preoperative, surgical, and postoperative data from 2 databases: the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO) and the Malaysian National Cataract Registry. The EUREQUO contains complete data from the national cataract registries in the Netherlands and Sweden. Preoperative and postoperative corrected distance visual acuity, preoperative ocular comorbidity in the surgery eye, and capsule complications during surgery. There were substantial differences in indication for surgery between the 3 national data sets. The percentage of eyes with a preoperative best-corrected visual acuity of 20/200 or worse varied from 7.1% to 72%. In all 3 data sets, the visual thresholds for cataract surgery decreased over time by 6% to 28% of the baseline values. The frequency of capsule complications varied between the 3 data sets, from 1.1% to 3.7% in 2008 and from 0.6% to 2.7% in 2012. An increasing postoperative visual acuity was also seen for all 3 data sets. A high frequency of capsule complication was related significantly to poor preoperative visual acuity, and a high frequency of decreased visual acuity after surgery was related significantly to excellent preoperative visual acuity. The 5-year trend in all 3 national data sets showed decreasing visual thresholds for surgery, decreasing surgical complication rates, and increasing visual outcomes regardless of the initial preoperative visual level. Cataract surgery on eyes with poor preoperative visual acuity was related to surgical complications, and cataract surgery on eyes with excellent preoperative visual acuity was related to adverse visual results. Copyright © 2015 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Mifflin, Mark D; Hatch, Bryndon B; Sikder, Shameema; Bell, James; Kurz, Christopher J; Moshirfar, Majid
2012-02-01
To determine whether VISX S4 (VISX Inc) custom photorefractive keratectomy (PRK) results in better visual outcomes than VISX S4 conventional PRK. Photorefractive keratectomy was performed on 80 eyes from 40 patients in this randomized, prospective, contralateral eye study. Dominant eyes were randomized to one group with the fellow eye receiving the alternate treatment. Primary outcome measures included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, and root-mean-square (RMS) higher order aberrations. Mean UDVA was -0.023±0.099 (20/19) in the custom group and -0.044±0.080 (20/18) in the conventional group 6 months after surgery (P=.293). Mean CDVA was -0.073±0.067 (20/17) in the custom group and -0.079±0.071 (20/17) in the conventional group 6 months after surgery (P=.659). Total higher order aberration RMS and spherical aberration increased in both groups compared to preoperative values (P<.05). Coma increased in the conventional group (P<.05) whereas it was similar to preoperative values in the custom group. No significant differences were noted in induction of trefoil. Custom and conventional PRK were shown to be safe and effective with excellent visual acuity and contrast sensitivity performance at 6 and 12 months. Conventional PRK induced more coma than custom PRK; however, this did not seem to correlate with clinical outcomes. Copyright 2012, SLACK Incorporated.
Brenner, Luis F
2015-12-01
To evaluate the changes in corneal higher-order aberrations (HOAs) and their impact on corneal higher-order Strehl ratio after aberration-free ablation profile. Verter Institute, H. Olhos, São Paulo, Brazil. Prospective interventional study. Eyes that had aberration-free myopic ablation were divided into 3 groups, based on the spherical equivalent (SE). The corneal HOAs and higher-order Strehl ratios were calculated before surgery and 3 months after surgery. The postoperative uncorrected-distance visual acuity, corrected-distance visual acuity, and SE did not present statistical differences among groups (88 eyes, P > .05). For a 6 mm pupil, the corneal HOA showed a mean increase of 0.17 μm (range 0.39 to 0.56 μm) (P < .001) and the corneal higher-order Strehl ratio presented a reduction of 0.03 (from 0.25 to 0.22) (P = .001). The following consistent linear predictive model was obtained: corneal HOA induction = 1.474 - 0.032 × SE - 0.225 × OZ, where OZ is the optical zone (R(2) = 0.49, adjusted R(2) = 0.48, P < .001). The corneal HOAs and the higher-order Strehl ratios deteriorated after moderate and high myopic ablations. The worsening in corneal aberrations and optical quality were related to the magnitude of the intended correction and did not affect high-contrast visual performance. The OZ was the only modifiable parameter capable to restrain the optical quality loss. The author has no financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Chung, Jin Kwon; Kim, Jin Kook; Lee, Jae Bum; Lee, Sung Jin
2013-10-01
To assess the efficacy and safety of iris-fixated phakic intraocular lens (pIOL) implantation to correct myopia in eyes with previous retinal detachment (RD) surgery. Department of Ophthalmology, Soonchunhyang University College of Medicine, Seoul, South Korea. Retrospective case series. Patients having pIOL implantation in both eyes were enrolled. Eyes that had scleral buckling or encircling (RD group) and healthy fellow eyes (non-RD group) were evaluated over a 6-year follow-up. The corrected distance visual acuity (CDVA), endothelial cell density (ECD), intraoperative complications, and long-term complications were safety outcomes. Uncorrected distance visual acuity (UDVA), predictability, and stability of refraction were efficacy outcomes. The study comprised 34 eyes (17 patients). The mean postoperative CDVA and ECD were not significantly different between groups, and no patient lost CDVA. The rate of transient intraocular pressure spike was significantly higher in the RD group (P=.043). After 3 years and 6 years, the mean postoperative UDVA was 0.06 logMAR ± 0.09 (SD) and 0.08 ± 0.10 logMAR, respectively, in the RD group and 0.04 ± 0.08 logMAR and 0.04 ± 0.09 logMAR, respectively, in the non-RD group (P=.518 and P=.478, respectively). The rate of eyes within ±0.50 diopter of the desired refraction and the postoperative refraction was not significantly different between groups. No eye had vitreoretinal changes requiring secondary surgical intervention. Iris-fixated pIOL implantation corrected the myopic refractive error in patients who had scleral buckling or encircling surgery for RD with a high degree of efficacy, safety, and long-term stability. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Haytoğlu, Süheyl; Haytoğlu, Tahir Gökhan; Kuran, Gökhan; Yıldırım, İlhami; Arıkan, Osman Kürşat
2017-04-01
The aim of this study was to investigate the efficacy, complication rates, patient satisfaction, and recurrence risks of the incisionless otoplasty technique performed with or without cartilage scoring for correcting the prominent ear in pediatric patients. A total of 49 patients with prominent ears were operated with incisionless otoplasty. In Group 1, 44 ears of 24 patients were operated with incisionless otoplasty without cartilage scoring. In Group 2, 46 ears of 25 patients were operated with incisionless otoplasty with cartilage scoring. For comparison, auriculocephalic distances were measured at three different levels: preoperatively, at the end of surgery, and at 1th and 6th month post-operatively. Patient satisfaction was evaluated using a visual analog scale (VAS). The global esthetic improvement scale (GAIS) was applied by an independent, non-participating plastic surgeon at 6 months after surgery. Prior to surgery and at the end of surgery, no statistically significant difference was observed between the groups in terms of auriculocephalic distances at the three levels. At the and 6th month after surgery, auriculocephalic distances were significantly higher in Group 1. There were no significant differences in VAS results and GAIS values between the groups. The recurrence rate was 9.1% in Group 1 and 4.3% in Group 2. The suture extrusion rate was 18.2% in Group 1 and 13% in Group 2. Although there was a significant difference of 1-2 mm in auriculocephalic distances, our study showed that cartilage scoring is not mandatory to correct the prominent ear in pediatric patients with soft cartilages and to achieve patient and surgeon satisfaction.
Toda, Ikuko; Ide, Takeshi; Fukumoto, Teruki; Ichihashi, Yoshiyuki; Tsubota, Kazuo
2014-03-01
To evaluate the possible advantages of combination therapy with diquafosol tetrasodium and sodium hyaluronate for dry eye after laser in situ keratomileusis (LASIK). Prospective randomized comparative trial. A total of 206 eyes of 105 patients who underwent LASIK were enrolled in this study. Patients were randomly assigned to 1 of 4 treatment groups according to the postoperative treatment: artificial tears, sodium hyaluronate, diquafosol tetrasodium, and a combination of hyaluronate and diquafosol. Questionnaire responses reflecting subjective dry eye symptoms, uncorrected and corrected visual acuity, functional visual acuity, manifest refraction, tear break-up time, fluorescein corneal staining, Schirmer test, and corneal sensitivity were examined before and 1 week and 1 month after LASIK. Distance uncorrected visual acuity was significantly better in the combination group than in the hyaluronate group 1 week and 1 month after LASIK. Near uncorrected visual acuity was significantly better in the combination group than in the artificial tear and diquafosol groups 1 week and 1 month after LASIK. Distance functional visual acuity improved significantly only in the combination group 1 month after LASIK. The Schirmer value in the combination group was significantly higher than that in the hyaluronate group at 1 month after LASIK. Subjective dry eye symptoms in the combination group improved significantly compared with those in the other groups 1 week after surgery. Our results suggest that hyaluronate and diquafosol combination therapy is beneficial for early stabilization of visual performance and improvement of subjective dry eye symptoms in patients after LASIK. Copyright © 2014 Elsevier Inc. All rights reserved.
Television Video Games in the Treatment of Amblyopia in Children Aged 4-7 Years.
Dadeya, Subhash; Dangda, Sonal
2016-12-01
To investigate the role of television video games in childhood amblyopia treatment. This prospective, randomized, interventional study included 40 patients between 4-7 years of age, with unilateral amblyopia (visual acuity in amblyopic eye between 1-0.6 LogMAR equivalents) attending the squint clinic at a tertiary eye hospital. All patients were prescribed optimal spectacle correction and occlusion therapy, i.e. full time patching according to patient's age, was initiated after six weeks.; full-time patching according to patient's age was initiated after 6 weeks. Subjects were randomly divided into two groups of 20 each. Patients in the first group, Group A (control), were prescribed patching alone. Patients in the second group, Group B (study), were made to play action video games, with the help of a commercial television set, along with patching. They attended 12 half-hour sessions each, at weekly intervals. Follow-up assessments included best corrected visual acuity (BCVA) (both distance and near) and stereoacuity measurements at 3, 6, 9, and 12 weeks. The mean age of patients was 6.03 ± 1.14 years. The distance BCVA in the amblyopic eye showed a significant improvement at final follow-up (12 weeks) in both groups: from 0.84 ± 0.19 to 0.55 ± 0.21 LogMAReq in Group A and 0.89 ± 0.16 to 0.46 ± 0.22 LogMAReq in Group B. However, improvement in BCVA was significantly better in group B at all visits (P=0.002, 12 weeks). The study group also had a significantly better outcome in terms near visual acuity improvement (P = 0.006, 12 weeks). There was also greater stereoacuity improvement in group B, with 7 patients improving to 100 secs of arc or better. Video games supplemental to occlusion may be considered favorable for visual development in amblyopic children, and the study encourages further research on this subject.
Vestergaard, Anders; Ivarsen, Anders; Asp, Sven; Hjortdal, Jesper Ø
2013-06-01
To present our initial clinical experience with ReLEx(®) flex (ReLEx) for moderate to high myopia. We compare efficacy, safety and corneal higher-order aberrations after ReLEx with femtosecond laser in situ keratomileusis (FS-LASIK). Prospective study of ReLEx compared with a retrospective study of FS-LASIK. ReLEx is a new keratorefractive procedure, where a stromal lenticule is cut by a femtosecond laser and manually extracted. Forty patients were treated with ReLEx on both eyes. A comparable group of 41 FS-LASIK patients were retrospectively identified. Visual acuity, spherical equivalent (SE) and corneal tomography were measured before and 3 months after surgery. Preoperative SE averaged -7.50 ± 1.16 D (ReLEx) and -7.32 ± 1.09 D (FS-LASIK). For all eyes, mean corrected distance visual acuity remained unchanged in both groups. For eyes with emmetropia as target refraction, 41% of ReLEx and 61% of FS-LASIK eyes had an uncorrected distance visual acuity of logMAR ≤ 0.10 at day 1 after surgery, increasing to, respectively, 88% and 69% at 3 months. Mean SE was -0.06 ± 0.35 D 3 months after ReLEx and -0.53 ± 0.60 D after FS-LASIK. The proportion of eyes within ±1.00 D after 3 months was 100% (ReLEx) and 85% (FS-LASIK). For a 6.0-mm pupil, corneal spherical aberrations increased significantly less in ReLEx than FS-LASIK eyes. ReLEx is an all-in-one femtosecond laser refractive procedure, and in this study, results were comparable to FS-LASIK. Refractive predictability and corneal aberrations at 3 months seemed better than or equal to FS-LASIK, whereas visual recovery after ReLEx was slower. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Bissen-Miyajima, Hiroko; Negishi, Kazuno; Hieda, Osamu; Kinoshita, Shigeru
2015-06-01
To evaluate the efficacy and safety of a new acrylic one-piece toric intraocular lens (IOL). This prospective multicenter clinical trial included 93 eyes of 61 patients that were implanted with a hydrophobic acrylic toric IOL from 2010 to 2012 and followed for 1 year. This IOL uses the platform of a microincision one-piece aspheric IOL, the NY-60 IOL (HOYA, Tokyo, Japan), with three increments in cylindrical power (NHT15, 1.5 diopters [D]; NHT23, 2.25 D; and NHT30, 3.0 D). The inclusion criterion was preoperative corneal astigmatism from 0.75 to 3.00 D. The primary endpoint was uncorrected distance visual acuity (UDVA) of 0.0 logMAR (20/20 Snellen) or better 6 months postoperatively. In addition to UDVA, corrected distance visual acuity (CDVA), residual astigmatism, stability of the IOL alignment, need of realignment, and the rate of Nd:YAG laser capsulotomy were evaluated up to 1 year postoperatively. Errors in astigmatic correction were assessed using Alpin's vector analysis. The primary endpoint was achieved in 54.8% of eyes. One year postoperatively, the logMAR UDVAs were 0.02 ± 0.13, 0.05 ± 0.17, and 0.09 ± 0.14 with models NHT15, NHT23, and NHT30, which corresponds to 0.96 (19/20 Snellen), 0.89 (18/20 Snellen), and 0.82 (16/20 Snellen), respectively. One year postoperatively, the residual astigmatism was 0.66 ± 0.58 D. In each evaluation, the mean absolute change in the position of the axis mark was between 1.93° and 2.32°. Three eyes required repositioning of the IOL axis and 2 eyes received Nd:YAG laser capsulotomy. The correction error showed an undercorrection with against-the-rule astigmatism and overcorrection with with-the-rule astigmatism. The new one-piece toric IOL provided desirable clinical outcomes and stability in eyes with corneal astigmatism. Copyright 2015, SLACK Incorporated.
Tomita, Minoru; Watabe, Miyuki; Yukawa, Satoshi; Nakamura, Nobuo; Nakamura, Tadayuki; Magnago, Thomas
2014-02-01
To evaluate the clinical outcomes of laser in situ keratomileusis (LASIK) to correct myopia or myopic astigmatism using the Amaris 750S 750 Hz excimer laser. Private LASIK center, Tokyo, Japan. Case series. Patients with myopia or myopic astigmatism (spherical equivalent -0.50 to -11.63 diopters [D]), a corrected distance visual acuity (CDVA) of 20/20 or better, and an estimated residual bed thickness of 300 μm or more had LASIK using the aspheric aberration-free ablation profile of the 750 Hz scanning-spot laser and the Femto LDV Crystal Line femtosecond laser for flap creation. Study parameters included uncorrected distance visual acuity (UDVA), CDVA, manifest refraction, astigmatism, and higher-order aberrations (HOAs). The study included 1280 eyes (685 patients). At 3 months, 96.6% of eyes had a UDVA of 20/20 or better and 99.1% had 20/32 or better; 94.1% of eyes were within ± 0.50 D of the intended correction and 98.9% were within ± 1.00 D; 89.7% of eyes had no residual cylinder and 96.0% had a postoperative astigmatism of less than 0.50 D. All eyes had a postoperative CDVA of 20/20 or better. The HOAs increased postoperatively (P<.001), with mean total postoperative corneal and ocular HOAs of 0.66 μm ± 0.20 (SD) and 0.56 ± 0.23 μm, respectively. The efficacy index and safety index were 1.02 and 1.06, respectively. Laser in situ keratomileusis with the 750 Hz scanning-spot laser was safe, effective, and predictable. No specific clinical side effects that might be associated with a high repetition rate occurred. Mr. Magnago is an employee of Schwind eye-tech-solutions GmbH. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
1997-11-01
Expanded subset of the illustration to clarify the locus of the off-axis end point of retinal stimulation for correct accommodation. 55 Figure...12c. Expanded illustration to clarify the locus of the off -axis end point of retinal stimulation for myopic accommodation. 55 Figure 12d...Expanded illustration to clarify the locus of the off -axis end point of retinal stimulation for hyperopic accommodation. 56 Figure 13. Simplified
Emergency vehicle alert system, phase 2
NASA Technical Reports Server (NTRS)
Barr, Tom; Harper, Warren; Reed, Bill; Wallace, David
1993-01-01
The EVAS provides warning for hearing-impaired motor vehicle drivers that an emergency vehicle is in the local vicinity. Direction and distance to the emergency vehicle are presented visually to the driver. This is accomplished by a special RF transmission/reception system. During this phase the receiver and transmitter from Phase 1 were updated and modified and a directional antenna developed. The system was then field tested with good results. Static and dynamic (moving vehicle) tests were made with the direction determined correctly 98 percent of the time.
Bourne, Rupert; Price, Holly; Taylor, Hugh; Leasher, Janet; Keeffe, Jill; Glanville, Julie; Sieving, Pamela C; Khairallah, Moncef; Wong, Tien Yin; Zheng, Yingfeng; Mathew, Anu; Katiyar, Suchitra; Mascarenhas, Maya; Stevens, Gretchen A; Resnikoff, Serge; Gichuhi, Stephen; Naidoo, Kovin; Wallace, Diane; Kymes, Steven; Peters, Colleen; Pesudovs, Konrad; Braithwaite, Tasanee; Limburg, Hans
2014-01-01
Purpose To describe a systematic review of population-based prevalence studies of visual impairment (VI) and blindness worldwide over the past 32 years that informs the Global Burden of Diseases, Injuries and Risk Factors Study. Methods A systematic review (Stage 1) of medical literature from 1 January 1980 to 31 January 2012 identified indexed articles containing data on incidence, prevalence and causes of blindness and VI. Only cross-sectional population-based representative studies were selected from which to extract data for a database of age- and sex-specific data of prevalence of 4 distance and one near visual loss categories (presenting and best-corrected). Unpublished data and data from studies using ‘rapid assessment’ methodology were later added (Stage 2). Results Stage 1 identified 14,908 references, of which 204 articles met the inclusion criteria. Stage 2 added unpublished data from 44 ‘rapid assessment studies’ and 4 other surveys. This resulted in a final dataset of 252 articles of 243 studies, of which 238 (98%) reported distance vision loss categories. Thirty-seven studies of the final dataset reported prevalence of mild VI and 4 reported near vision impairment. Conclusion We report a comprehensive systematic review of over 30 years of VI/blindness studies. While there has been an increase in population-based studies conducted in the 2000’s compared to previous decades; there is limited information from certain regions (eg. Central Africa and Central and Eastern Europe, and the Caribbean and Latin America), younger age groups and minimal data regarding prevalence of near vision and mild distance visual impairment. PMID:23350553
Khoramnia, Ramin; Fitting, Anna; Rabsilber, Tanja M; Thomas, Bettina C; Auffarth, Gerd U; Holzer, Mike P
2015-02-01
To assess over a 36-month period functional results of the modified INTRACOR femtosecond laser-based intrastromal procedure to treat presbyopia. 20 eyes of 20 presbyopic patients with mild hyperopia were included. The INTRACOR procedure with a modified pattern (six concentric intrastromal ring cuts) was performed using the FEMTEC femtosecond laser (Bausch+Lomb/Technolas Perfect Vision, Munich, Germany). Patients were also randomly divided into three subgroups to compare the effect of three different small inner ring diameters (1.8/2.0/2.2 mm (Groups A/B/C)). Follow-up examinations were performed at 1, 3, 6, 12, 24 and 36 months, and included near and distance visual acuity tests, slit-lamp examinations and corneal topography. Median uncorrected near visual acuity (UNVA) increased from 0.7/0.7/0.7 logMAR (Groups A/B/C) to -0.1/0.1/0.1 logMAR 36 months after surgery. Uncorrected distance visual acuity changed slightly from 0.1/0.2/0.1 logMAR to 0.2/0.3/0.1 logMAR. Losses of two lines of binocular corrected distance visual acuity (CDVA) were noted in 0/25/0% of eyes. Median spherical equivalent changed from 0.75/0.75/0.75 dioptres to -0.19/0.13/-0.19 dioptres. Overall patient satisfaction with the procedure was 80%. INTRACOR with a modified pattern improved UNVA in all patients over a 36-month follow-up period. The possibility of reduced CDVA underlines the need for careful patient selection. NCT00928122. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Basarir, Berna; Kaya, Vedat; Altan, Cigdem; Karakus, Sezen; Pinarci, Eylem Y; Demirok, Ahmet
2012-01-01
To evaluate the safety and efficacy of piggybacking with the HumanOptics Add-On intraocular lens (IOL) to correct pseudophakic refractive errors. Ten eyes of 10 patients with pseudophakic refractive errors were included in this study. All patients were targeted for a range of refraction -0.50 to +0.50 D. Uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), endothelial cell count (ECC), anterior chamber depth (ACD), the distance between intraocular lenses, and contrast sensitivity measurements under mesopic, scotopic, and scotopic with glare conditions were evaluated preoperatively and postoperatively. The mean age of the patients was 54±27 years (range 4-78). Mean follow-up time was 10.5±1.36 months (range 6-15 months). Mean diopters of implanted Add-On IOLs were -1.4±6.9 (range -12 to +9 D). Mean preoperative and postoperative UDVA was 0.133±0.12 and 0.73±0.27, respectively (p=0.0001); mean preoperative and postoperative CDVA were 0.77±0.26 and 0.79±0.27, respectively (p=0.066). Mean preoperative and postoperative ACD were 3.87±0.91 mm vs 3.58±1.05 mm, respectively (p=0.343); mean inter-IOL distance was 0.53±0.08 mm. Mean preoperative and postoperative ECC were 2455±302 and 2426±294, respectively (p=0.55). All patients were within the targeted refractive range of -0.50 D to +0.50 D. No complications were observed during the operations or postoperative follow-up period. Piggybacking with the Add-On IOL is a safe, efficient, and reliable technique to correct pseudophakic refractive errors.
Correcting lenticular astigmatism by reinstating the correct neuromuscular message.
Yee, John William
2013-07-01
The spasm of the oblique muscles can contribute to lenticular astigmatism. The visual cortex interprets the tension of the oblique muscles as an eye that is in near focus mode. It overrides the response to the information generated by depth perception to bring a distant image into focus. Any excessive effort to bring it into focus will not be successful and continuing to make that effort can cause a misalignment in the tension of the rectus muscles. This in turn can directly induce corneal astigmatism and indirectly induce lenticular astigmatism. The astigmatic eye can still bring a near image into focus, but a distant image remains aberrant. The design of a special contact lens to treat lenticular astigmatism is similar to the design of a contact lens to treat corneal astigmatism by means of orthoculogy (or ortho C) as outlined in the paper Correcting Corneal Astigmatism by Reinstating the Correct Neuromuscular Message. The ortho C lens is worn for about two minutes to attend to the blur and distorted aspects of "simple myopic astigmatism". Both of these refractive errors are corrected simultaneously. Once the oblique muscles become "loose" due to a "contact lens draw", it triggers the visual cortex to reinstate the proper neuromotor message to stimulate the ciliary muscle (the muscle that controls the shape of the crystalline lens) to relax along a certain meridian-which in turn "flattens" the crystalline lens along that meridian to bring a blur and distorted image in the distance into focus. The correction only takes a few minutes because the ciliary muscle of an astigmatic eye was not compromised. The correction is not strictly due to an ortho C lens. Its design is the same for corneal astigmatism or lenticular astigmatism. The purpose of the design is to "loosen" the oblique muscles in a certain manner depending on the degree of astigmatism instead of a specific type of astigmatism. The visual cortex can discriminate whether to correct for corneal astigmatism or lenticular astigmatism after the "draw" from the lens relaxes the oblique muscles. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Xue, Lixia; Dai, Yun; Rao, Xuejun; Wang, Cheng; Hu, Yiyun; Liu, Qian; Jiang, Wenhan
2008-01-01
Higher-order aberrations correction can improve visual performance of human eye to some extent. To evaluate how much visual benefit can be obtained with higher-order aberrations correction we developed an adaptive optics vision simulator (AOVS). Dynamic real time optimized modal compensation was used to implement various customized higher-order ocular aberrations correction strategies. The experimental results indicate that higher-order aberrations correction can improve visual performance of human eye comparing with only lower-order aberration correction but the improvement degree and higher-order aberration correction strategy are different from each individual. Some subjects can acquire great visual benefit when higher-order aberrations were corrected but some subjects acquire little visual benefit even though all higher-order aberrations were corrected. Therefore, relative to general lower-order aberrations correction strategy, customized higher-order aberrations correction strategy is needed to obtain optimal visual improvement for each individual. AOVS provides an effective tool for higher-order ocular aberrations optometry for customized ocular aberrations correction.
Yang, Yuan; Quan, Nannan; Bu, Jingjing; Li, Xueping; Yu, Ningmei
2016-09-26
High order modulation and demodulation technology can solve the frequency requirement between the wireless energy transmission and data communication. In order to achieve reliable wireless data communication based on high order modulation technology for visual prosthesis, this work proposed a Reed-Solomon (RS) error correcting code (ECC) circuit on the basis of differential amplitude and phase shift keying (DAPSK) soft demodulation. Firstly, recognizing the weakness of the traditional DAPSK soft demodulation algorithm based on division that is complex for hardware implementation, an improved phase soft demodulation algorithm for visual prosthesis to reduce the hardware complexity is put forward. Based on this new algorithm, an improved RS soft decoding method is hence proposed. In this new decoding method, the combination of Chase algorithm and hard decoding algorithms is used to achieve soft decoding. In order to meet the requirements of implantable visual prosthesis, the method to calculate reliability of symbol-level based on multiplication of bit reliability is derived, which reduces the testing vectors number of Chase algorithm. The proposed algorithms are verified by MATLAB simulation and FPGA experimental results. During MATLAB simulation, the biological channel attenuation property model is added into the ECC circuit. The data rate is 8 Mbps in the MATLAB simulation and FPGA experiments. MATLAB simulation results show that the improved phase soft demodulation algorithm proposed in this paper saves hardware resources without losing bit error rate (BER) performance. Compared with the traditional demodulation circuit, the coding gain of the ECC circuit has been improved by about 3 dB under the same BER of [Formula: see text]. The FPGA experimental results show that under the condition of data demodulation error with wireless coils 3 cm away, the system can correct it. The greater the distance, the higher the BER. Then we use a bit error rate analyzer to measure BER of the demodulation circuit and the RS ECC circuit with different distance of two coils. And the experimental results show that the RS ECC circuit has about an order of magnitude lower BER than the demodulation circuit when under the same coils distance. Therefore, the RS ECC circuit has more higher reliability of the communication in the system. The improved phase soft demodulation algorithm and soft decoding algorithm proposed in this paper enables data communication that is more reliable than other demodulation system, which also provide a significant reference for further study to the visual prosthesis system.
Prenatal Phthalate, Triclosan, and Bisphenol A Exposures and Child Visual-Spatial Abilities
Braun, Joseph M.; Bellinger, David C.; Hauser, Russ; Wright, Robert O.; Chen, Aimin; Calafat, Antonia M.; Yolton, Kimberly; Lanphear, Bruce P.
2016-01-01
Introduction During fetal development, sex steroids influence sexually dimorphic behaviors, such as visual-spatial abilities. Thus, endocrine disrupting chemicals that impact sex steroids during gestation may affect these behaviors. Objective We investigated the relationship between prenatal urinary phthalate metabolite, triclosan, and BPA concentrations and visual-spatial abilities in a prospective cohort of 198 mother-child dyads. Methods Data are from a prospective cohort in Cincinnati, OH (HOME Study). We measured nine phthalate metabolites, triclosan, and BPA in maternal urine samples collected at 16 and 26 weeks of gestation. We assessed children’s visual-spatial abilities at 8 years of age using the Virtual Morris Water Maze (VMWM), a computerized version of the rodent Morris Water Maze. We quantified the covariate-adjusted change in the time or distance to complete the VMWM and time spent in the correct quadrant during a probe trial with an interquartile range increase in chemical concentrations using linear mixed models and linear regression, respectively. Results Boys completed the VMWM faster (4.1 seconds; 95% CI:−7.1, −1.2) and in less distance (1.4 units; 95% CI:−2.8, 0) than girls. Overall, children with higher mono-n-butyl (MnBP), mono- benzyl (MBzP), and mono-carboxypropyl phthalate concentrations completed the VMWM in less time and distance than children with lower concentrations. For example, children with higher MnBP concentrations completed the VMWM in 0.9 less distance units (95% CI:−1.8, −0.0). Child sex modified the association between MnBP and VMWM performance. In girls, higher MnBP concentrations were associated with longer time (1.7 seconds; 95% CI: −0.7, 4.1) and shorter distance (−1.7 units; 95% CI: −2.8, −0.5), whereas in boys, it was associated with shorter time (−3.0 seconds; 95% CI:−5.6, −0.4), but not distance (−0.1 units; 95% CI:1.4, 1.0). Other phthalate metabolites, triclosan, and BPA were not associated with VMWM performance, and sex did not consistently modify these associations. Conclusions In this cohort, greater prenatal urinary concentrations of some phthalate metabolites were associated with improved VMWM performance, particularly among boys. Future studies should confirm these findings and determine if phthalates affect other hormonally sensitive aspects of child neurobehavior. PMID:27888119
Le Loir, M; Cochener, B
2012-06-01
To assess efficacy, stability and safety of posterior chamber phakic intraocular lens implantation with STAAR Visian ICL for correction of high ametropia, with a mean follow-up of 5 years (3.5-10 years). Ninety eyes of 53 highly ametropic patients (45 myopia, ten hyperopia and 35 with mixed astigmatism) were included in a retrospective single-surgeon study, using primarily the V4 ICL model (87 eyes). We studied pre- and postoperative refractive efficacy, endothelial cell density, crystalline lens opacification and intraocular clearances within the various compartments of the eye. Mean uncorrected visual acuity was 0.77 at the 12th postoperative month; 17 of 90 eyes required adjunctive photoablation for residual astigmatism. Forty-eight percent of eyes gained at least one line of best corrected visual acuity. After implantation, the decrease in endothelial cell density remained stable at 0.69%/year, and 91% of eyes showed no opacification of the crystalline lens. Mean endothelium-ICL and ICL-crystalline lens distances were 2.41 mm and 0.52 mm respectively. Overall patient satisfaction achieved was 96% at 36 months postoperatively. These results demonstrate efficacy, stability and safety of the ICL V4 phakic IOL for the correction of high ametropia. Long-term follow-up did not show a significant increase in cataract formation in implanted eyes. Copyright © 2012. Published by Elsevier Masson SAS.
Arad, Tschingis; Baumeister, Martin; Bühren, Jens; Kohnen, Thomas
2017-04-20
Automated measurements of reading performance are required for clinical trials involving presbyopia-correcting surgery options. Repeatability of a testing device for reading (Salzburg Reading Desk) was evaluated in a prepresbyopic population. Subjective reading performance of 50 subjects divided into 2 age groups (23-30 years and 38-49 years) with distance-corrected eyes was investigated with different log-scaled reading charts. At study entry, refractive parameters were measured and distance visual acuity assessed. Two standardized binocular measurements were performed for each subject (32.24 ± 9.87 days apart [mean ± SD]). The repeatability of the tests was estimated using correlation coefficients, Wilcoxon signed-rank test, and Bland-Altman method. The test parameters at both maximum reading rate (MRR) measurements demonstrate a strong relationship of age group 2 subjects (correlation coefficient [r] = 0.74 p = 10-4) and of younger subjects (age group 1: r = 0.69, p = 10-4). Prepresbyopic subjects of age group 2 showed moderate results for near reading distance (r = 0.67, p = 10-4); by contrast, younger subjects had poorer results (r = 0.55, p = 10-3). The Wilcoxon signed-rank test revealed agreement between measurements and Bland-Altman plots showed a wide data spread for MRR and near reading distance in both groups. The device measures repeatedly selected reading performance parameters of near real world conditions, such as MRR, in prepresbyopic populations if several factors are taken into account. The option to choose preferred distance leads to more variance in measuring repeated reading performance. German Clinical Trials Register (DRKS) registration reference number: DRKS00000784.
Purtscher-like retinopathy in acute alcoholic pancreatitis
Nema, Nitin; Ishrat, Saba; Verma, Abha; Kela, Manoj
2016-01-01
A 23-year-old man with a history of alcoholism presented with vomiting, fever, and sharp epigastric pain radiating to the back and flanks. He was diagnosed as a case of acute alcoholic pancreatitis on the basis of clinical findings and investigations. On the next day of presentation, he developed sudden bilateral visual loss. His best-corrected visual acuity was finger counting at one-foot distance in both eyes. He had diffuse whitening in the circumpapillary area, haloes around the retinal vessels (Purtscher flecken) and intra-retinal hemorrhages on ophthalmoscopic examination. Optical coherence tomography revealed bilateral macular edema. These findings were characteristic of Purtscher-like retinopathy. The patient showed systemic and visual improvement at 8 weeks follow-up after receiving the conventional treatment for acute alcoholic pancreatitis. This case emphasizes the importance of fundus examination by an ophthalmologist in the diagnosis of this rare under-diagnosed entity. PMID:27433040
Purtscher-like retinopathy in acute alcoholic pancreatitis.
Nema, Nitin; Ishrat, Saba; Verma, Abha; Kela, Manoj
2016-01-01
A 23-year-old man with a history of alcoholism presented with vomiting, fever, and sharp epigastric pain radiating to the back and flanks. He was diagnosed as a case of acute alcoholic pancreatitis on the basis of clinical findings and investigations. On the next day of presentation, he developed sudden bilateral visual loss. His best-corrected visual acuity was finger counting at one-foot distance in both eyes. He had diffuse whitening in the circumpapillary area, haloes around the retinal vessels (Purtscher flecken) and intra-retinal hemorrhages on ophthalmoscopic examination. Optical coherence tomography revealed bilateral macular edema. These findings were characteristic of Purtscher-like retinopathy. The patient showed systemic and visual improvement at 8 weeks follow-up after receiving the conventional treatment for acute alcoholic pancreatitis. This case emphasizes the importance of fundus examination by an ophthalmologist in the diagnosis of this rare under-diagnosed entity.
Zhao, Jing; Zhao, Feng; Huang, Jinrong; Xu, Haipeng; Chen, Yingjun; Zhou, Xingtao
2018-04-01
To describe a patient with flap complications after LASIK who was subsequently treated using phototherapeutic keratectomy (PTK) and an autologous lenticule transplant obtained via small incision lenticule extraction (SMILE). A 23-year-old man experienced free flap and partial flap loss in the left eye following LASIK, resulting in corneal stroma opacity 1 month later. The manifest refraction was -3.25 diopters sphere (DS)/-0.50 diopters cylinder (DC) × 100° in the right eye and +2.50 DS/-1.25 DC × 155° in the left eye. His left eye was treated with PTK and transplantation of an autologous lenticule obtained from his right eye using the SMILE procedure. At the 2-year follow-up visit, the uncorrected distance visual acuity of the left eye had improved from 20/100 to 20/22 and the corrected distance visual acuity had improved from 20/25 to 20/18. Central corneal thickness had increased from 464 to 499 µm. The mean keratometry value had decreased from 45.00 diopters (D) at the 1-month follow-up visit to 39.40 D at the 2-year follow-up visit. Optical coherence tomography examination revealed that the lenticule remained transparent and exhibited a visible demarcation line. The transplantation of an autologous lenticule obtained via SMILE combined with PTK improved uncorrected and corrected acuity in this patient with flap loss after LASIK. [J Refract Surg. 2018;34(4):281-285.]. Copyright 2018, SLACK Incorporated.
Gharaibeh, Almutez M.; Villanueva, Asier; Mas, David; Espinosa, Julian
2018-01-01
Purpose To assess anterior corneal surface stability 12 months following hyperopic LASIK correction with a light propagation algorithm. Setting Vissum Instituto Oftalmológico de Alicante, Universidad Miguel Hernández, Alicante, Spain. Methods This retrospective consecutive observational study includes 37 eyes of 37 patients treated with 6th-generation excimer laser platform (Schwind Amaris). Hyperopic LASIK was performed in all of them by the same surgeon (JLA) and completed 12-month follow-up. Corneal topography was analyzed with a light propagation algorithm, to assess the stability of the corneal outcomes along one year of follow-up. Results Between three and twelve months postoperatively, an objective corneal power (OCP) regression of 0.39 D and 0.41 D was found for 6 mm and 9 mm central corneal zone, respectively. Subjective outcomes at the end of the follow-up period were as follows: 65% of eyes had spherical equivalent within ±0.50 D. 70% of eyes had an uncorrected distance visual acuity 20/20 or better. 86% of eyes had the same or better corrected distance visual acuity. In terms of stability, 0.14 D of regression was found. No statistically significant differences were found for all the study parameters evaluated at different postoperative moments over the 12-month period. Conclusions Light propagation analysis confirms corneal surface stability following modern hyperopic LASIK with a 6th-generation excimer laser technology over a 12-month period. PMID:29785300
Background colour matching by a crab spider in the field: a community sensory ecology perspective.
Defrize, Jérémy; Théry, Marc; Casas, Jérôme
2010-05-01
The question of whether a species matches the colour of its natural background in the perspective of the correct receiver is complex to address for several reasons; however, the answer to this question may provide invaluable support for functional interpretations of colour. In most cases, little is known about the identity and visual sensory abilities of the correct receiver and the precise location at which interactions take place in the field, in particular for mimetic systems. In this study, we focused on Misumena vatia, a crab spider meeting the criteria for assessing crypsis better than many other models, and claimed to use colour changes for both aggressive and protective crypsis. We carried out a systematic field survey to quantitatively assess the exactness of background colour matching in M. vatia with respect to the visual system of many of its receivers within the community. We applied physiological models of bird, bee and blowfly colour vision, using flower and spider spectral reflectances measured with a spectroradiometer. We observed that crypsis at long distance is systematically achieved, exclusively through achromatic contrast, in both bee and bird visions. At short distance, M. vatia is mostly chromatically detectable, whatever the substrate, for bees and birds. However, spiders can be either poorly discriminable or quite visible depending on the substrate for bees. Spiders are always chromatically undetectable for blowflies. We discuss the biological relevance of these results in both defensive and aggressive contexts of crypsis within a community sensory perspective.
Iris reconstruction using artificial iris prosthesis for management of aniridia.
Mostafa, Yehia S; Osman, Amr A; Hassanein, Dina H; Zeid, Ashraf M; Sherif, Ahmed M
2018-01-01
To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract. This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients. All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance. BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.
Jun, Ikhyun; Kang, David Sung Yong; Reinstein, Dan Z; Arba-Mosquera, Samuel; Archer, Timothy J; Seo, Kyoung Yul; Kim, Tae-Im
2018-03-01
To comparatively investigate the clinical outcomes, vector parameters, and corneal aberrations of small incision lenticule extraction (SMILE) with a triple centration technique and corneal wavefront-guided transepithelial photorefractive keratectomy (PRK) for the correction of high astigmatism. This retrospective, comparative case series study included 89 eyes (89 patients) that received treatment for myopia with high astigmatism (≥ 2.50 diopters) using SMILE with a triple centration technique (SMILE group; 45 eyes) and corneal wavefront-guided transepithelial PRK (transepithelial PRK group; 44 eyes). Visual acuity measurement, manifest refraction, slit-lamp examination, autokeratometry, corneal topography, and evaluation of corneal wavefront aberration were performed preoperatively and at 1, 3, and 6 months after surgery. The safety, efficacy, vector parameters, and corneal aberrations at 6 months after surgery were compared between the two groups. At 6 months after surgery, the transepithelial PRK and SMILE groups exhibited comparable mean uncorrected distance visual acuities (-0.06 ± 0.07 and -0.05 ± 0.07 logMAR, respectively), safety, efficacy, and predictability of refractive and visual outcomes. There was a slight but statistically significant difference in the correction index between the transepithelial PRK and SMILE groups (0.96 ± 0.11 and 0.91 ± 0.10, respectively). Whereas the transepithelial PRK group exhibited increased corneal spherical aberration and significantly reduced corneal coma and trefoil, no changes in aberrometric values were noted in the SMILE group. Both SMILE with a triple centration technique and corneal wavefront-guided transepithelial PRK are effective and provide predictable outcomes for the correction of high myopic astigmatism, although slight undercorrection was observed in the SMILE group. The triple centration technique was helpful in astigmatism correction by SMILE. [J Refract Surg. 2018;34(3):156-163.]. Copyright 2018, SLACK Incorporated.
Kobashi, Hidenaga; Kamiya, Kazutaka; Igarashi, Akihito; Takahashi, Masahide; Shimizu, Kimiya
2018-03-01
To compare the 2-years visual and refractive outcomes between small-incision lenticule extraction (SMILE) and wavefront-guided laser in situ keratomileusis (LASIK) in eyes with myopia and myopic astigmatism. Our retrospective case-control study examined 30 eyes of 30 patients with the manifest refraction spherical equivalent (MRSE) of -3.71 ± 1.83 dioptres (D) who underwent SMILE and 30 eyes of 30 patients with MRSE of -3.81 ± 1.40 D who underwent wavefront-guided LASIK. We assessed the 2-years clinical outcomes. Logarithm of the minimal angle of resolution (LogMAR)-corrected distance visual acuity (CDVA) was -0.23 ± 0.07 in the SMILE group and -0.24 ± 0.07 in the wavefront-guided LASIK group 2 years postoperatively (p = 0.82). Logarithm of the minimal angle of resolution-uncorrected distance visual acuity (UDVA) was -0.18 ± 0.09 and -0.15 ± 0.11 (p = 0.30, respectively). In the SMILE and wavefront-guided LASIK groups 2 years postoperatively, 100% and 73% of eyes, respectively, were within 0.5 D of the prompted MRSE correction (p = 0.005). Changes in the MRSE of -0.10 ± 0.30 D and -0.23 ± 0.51 D occurred from 3 months to 2 years (p = 0.40, respectively). We found a significant correlation between myopic regression and the changes in the keratometric readings from 3 months to 2 years after wavefront-guided LASIK (r = -0.48, p = 0.002), but not after SMILE (r = -0.004, p = 0.90). Small-incision lenticule extraction offers better refractive outcomes than wavefront-guided LASIK during a 2-years follow-up for the correction of myopia and myopic astigmatism. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Kuchenbecker, J; Blum, M; Paul, F
2016-03-01
In acute unilateral optic neuritis (ON) color vision defects combined with a decrease in visual acuity and contrast sensitivity frequently occur. This study investigated whether a web-based color vision test is a reliable detector of acquired color vision defects in ON and, if so, which charts are particularly suitable. In 12 patients with acute unilateral ON, a web-based color vision test ( www.farbsehtest.de ) with 25 color plates (16 Velhagen/Broschmann and 9 Ishihara color plates) was performed. For each patient the affected eye was tested first and then the unaffected eye. The mean best-corrected distance visual acuity (BCDVA) in the ON eye was 0.36 ± 0.20 and 1.0 ± 0.1 in the contralateral eye. The number of incorrectly read plates correlated with the visual acuity. For the ON eye a total of 134 plates were correctly identified and 166 plates were incorrectly identified, while for the disease-free fellow eye, 276 plates were correctly identified and 24 plates were incorrectly identified. Both of the blue/yellow plates were identified correctly 14 times and incorrectly 10 times using the ON eye and exclusively correctly (24 times) using the fellow eye. The Velhagen/Broschmann plates were incorrectly identified significantly more frequently in comparison with the Ishihara plates. In 4 out of 16 Velhagen/Broschmann plates and 5 out of 9 Ishihara plates, no statistically significant differences between the ON eye and the fellow eye could be detected. The number of incorrectly identified plates correlated with a decrease in visual acuity. Red/green and blue/yellow plates were incorrectly identified significantly more frequently with the ON eye, while the Velhagen/Broschmann color plates were incorrectly identified significantly more frequently than the Ishihara color plates. Thus, under defined test conditions the web-based color vision test can also be used to detect acquired color vision defects, such as those caused by ON. Optimization of the test by altering the combination of plates may be a useful next step.
Clinical characteristics and causes of visual impairment in a low vision clinic in northern Jordan.
Bakkar, May M; Alzghoul, Eman A; Haddad, Mera F
2018-01-01
The aim of the study was to identify causes of visual impairment among patients attending a low vision clinic in the north of Jordan and to study the relevant demographic characteristics of these patients. The retrospective study was conducted through a review of clinical records of 135 patients who attended a low vision clinic in Irbid. Clinical characteristics of the patients were collected, including age, gender, primary cause of low vision, best corrected visual acuity, and current prescribed low vision aids. Descriptive statistics analysis using numbers and percentages were calculated to summarize categorical and nominal data. A total of 135 patients (61 [45.2%] females and 74 [54.8%] males) were recruited in the study. Mean age ± standard deviation for the study population was 24.53 ± 16.245 years; age range was 5-90 years. Of the study population, 26 patients (19.3%) had mild visual impairment, 61 patients (45.2%) had moderate visual impairment, 27 patients (20.0%) had severe visual impairment, and 21 patients (15.6%) were blind. The leading causes of visual impairment across all age groups were albinism (31.9%) and retinitis pigmentosa (RP) (18.5%). Albinism also accounted for the leading cause of visual impairment among the pediatric age group (0-15 years) while albinism, RP, and keratoconus were the primary causes of visual impairment for older patients. A total of 59 patients (43.7%) were given low vision aids either for near or distance. The only prescribed low vision aids for distances were telescopes. For near, spectacle-type low vision aid was the most commonly prescribed low vision aids. Low vision services in Jordan are still very limited. A national strategy programme to increase awareness of low vision services should be implemented, and health care policies should be enforced to cover low vision aids through the national medical insurance.
Clinical characteristics and causes of visual impairment in a low vision clinic in northern Jordan
Bakkar, May M; Alzghoul, Eman A; Haddad, Mera F
2018-01-01
Aim The aim of the study was to identify causes of visual impairment among patients attending a low vision clinic in the north of Jordan and to study the relevant demographic characteristics of these patients. Subjects and methods The retrospective study was conducted through a review of clinical records of 135 patients who attended a low vision clinic in Irbid. Clinical characteristics of the patients were collected, including age, gender, primary cause of low vision, best corrected visual acuity, and current prescribed low vision aids. Descriptive statistics analysis using numbers and percentages were calculated to summarize categorical and nominal data. Results A total of 135 patients (61 [45.2%] females and 74 [54.8%] males) were recruited in the study. Mean age ± standard deviation for the study population was 24.53 ± 16.245 years; age range was 5–90 years. Of the study population, 26 patients (19.3%) had mild visual impairment, 61 patients (45.2%) had moderate visual impairment, 27 patients (20.0%) had severe visual impairment, and 21 patients (15.6%) were blind. The leading causes of visual impairment across all age groups were albinism (31.9%) and retinitis pigmentosa (RP) (18.5%). Albinism also accounted for the leading cause of visual impairment among the pediatric age group (0–15 years) while albinism, RP, and keratoconus were the primary causes of visual impairment for older patients. A total of 59 patients (43.7%) were given low vision aids either for near or distance. The only prescribed low vision aids for distances were telescopes. For near, spectacle-type low vision aid was the most commonly prescribed low vision aids. Conclusion Low vision services in Jordan are still very limited. A national strategy programme to increase awareness of low vision services should be implemented, and health care policies should be enforced to cover low vision aids through the national medical insurance. PMID:29662299
Correction of spin diffusion during iterative automated NOE assignment
NASA Astrophysics Data System (ADS)
Linge, Jens P.; Habeck, Michael; Rieping, Wolfgang; Nilges, Michael
2004-04-01
Indirect magnetization transfer increases the observed nuclear Overhauser enhancement (NOE) between two protons in many cases, leading to an underestimation of target distances. Wider distance bounds are necessary to account for this error. However, this leads to a loss of information and may reduce the quality of the structures generated from the inter-proton distances. Although several methods for spin diffusion correction have been published, they are often not employed to derive distance restraints. This prompted us to write a user-friendly and CPU-efficient method to correct for spin diffusion that is fully integrated in our program ambiguous restraints for iterative assignment (ARIA). ARIA thus allows automated iterative NOE assignment and structure calculation with spin diffusion corrected distances. The method relies on numerical integration of the coupled differential equations which govern relaxation by matrix squaring and sparse matrix techniques. We derive a correction factor for the distance restraints from calculated NOE volumes and inter-proton distances. To evaluate the impact of our spin diffusion correction, we tested the new calibration process extensively with data from the Pleckstrin homology (PH) domain of Mus musculus β-spectrin. By comparing structures refined with and without spin diffusion correction, we show that spin diffusion corrected distance restraints give rise to structures of higher quality (notably fewer NOE violations and a more regular Ramachandran map). Furthermore, spin diffusion correction permits the use of tighter error bounds which improves the distinction between signal and noise in an automated NOE assignment scheme.
Khoramnia, Ramin; Auffarth, Gerd U; Rabsilber, Tanja M; Holzer, Mike P
2012-11-01
We report a 66-year-old patient who presented with increasing hyperopia, astigmatism, and presbyopia in both eyes 8 years after bilateral laser in situ keratomileusis (LASIK) and LASIK enhancement in the left eye aiming for spectacle independence. Bilateral multifocal toric Lentis Mplus intraocular lenses (IOLs) with an embedded near segment and individually customized cylinder correction were implanted uneventfully following phacoemulsification. The Haigis-L formula after previous hyperopia correction was chosen for IOL power calculation and provided reliable results. Emmetropia was targeted and achieved. Three months postoperatively, the uncorrected distance visual acuity had increased from 0.40 logMAR to 0.10 logMAR in the right eye and from 0.20 logMAR to 0.00 logMAR in the left eye. The patient gained 6 lines of uncorrected near visual acuity: 0.20 logMAR in the right eye and 0.10 logMAR in the left eye. This case shows that customized premium IOL implantation can provide accurate results even in challenging cases. The International Vision Correction Research Centre, Department of Ophthalmology, University of Heidelberg, Heidelberg, Germany, has received research grants, lecture fees, and travel reimbursement from Oculentis GmbH. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Denion, E; Dedes, V; Bonne, M; Labalette, P; Berger, C; Guilbert, F; Bouckehove, S; Rouland, J-F
2004-11-01
The aim of this study is to investigate the importance of occlusion therapy for amblyopia in patients with partial unilateral congenital cataracts that were discovered after 24 months of age. A retrospective study was conducted on 11 patients, each of whom underwent a clinical examination including a cycloplegic refraction with atropine. The average age when the cataract was diagnosed was 35 months. The average distance visual acuity was 6/78 and the average near visual acuity was 35/175. Occlusion therapy using adhesive patches was started after refractive error correction. In two cases, observance was mediocre. Ametropia was found in every patient, with anisometropia in nine patients (alpha < 0.02). This anisometropia included an astigmatism that was always greater on the side with the cataract (alpha < 0.001), averaging 2.7 diopters. After occlusion therapy for amblyopia, the average visual acuity significantly improved to 6/22 in distance vision (alpha < 0.02) and 35/45 in near vision (alpha < 0.01). The average follow-up period was 28 months (5-60 months). Amblyopia is related to lens opacities as well as frequently associated anisometropia. Functional improvement is greater in near vision than in distance vision. With occlusion therapy for amblyopia, accommodation is preserved. This factor is of utmost importance as near vision is preferential in young children. This study provides an opportunity to recall the importance of refraction and occlusion therapy for amblyopia, which must be systematically attempted in cases of partial unilateral congenital cataracts before considering a surgical procedure.
Rocha, Karolinne Maia; Vabre, Laurent; Chateau, Nicolas; Krueger, Ronald R
2010-01-01
To evaluate the changes in visual acuity and visual perception generated by correcting higher order aberrations in highly aberrated eyes using a large-stroke adaptive optics visual simulator. A crx1 Adaptive Optics Visual Simulator (Imagine Eyes) was used to correct and modify the wavefront aberrations in 12 keratoconic eyes and 8 symptomatic postoperative refractive surgery (LASIK) eyes. After measuring ocular aberrations, the device was programmed to compensate for the eye's wavefront error from the second order to the fifth order (6-mm pupil). Visual acuity was assessed through the adaptive optics system using computer-generated ETDRS opto-types and the Freiburg Visual Acuity and Contrast Test. Mean higher order aberration root-mean-square (RMS) errors in the keratoconus and symptomatic LASIK eyes were 1.88+/-0.99 microm and 1.62+/-0.79 microm (6-mm pupil), respectively. The visual simulator correction of the higher order aberrations present in the keratoconus eyes improved their visual acuity by a mean of 2 lines when compared to their best spherocylinder correction (mean decimal visual acuity with spherocylindrical correction was 0.31+/-0.18 and improved to 0.44+/-0.23 with higher order aberration correction). In the symptomatic LASIK eyes, the mean decimal visual acuity with spherocylindrical correction improved from 0.54+/-0.16 to 0.71+/-0.13 with higher order aberration correction. The visual perception of ETDRS letters was improved when correcting higher order aberrations. The adaptive optics visual simulator can effectively measure and compensate for higher order aberrations (second to fifth order), which are associated with diminished visual acuity and perception in highly aberrated eyes. The adaptive optics technology may be of clinical benefit when counseling patients with highly aberrated eyes regarding their maximum subjective potential for vision correction. Copyright 2010, SLACK Incorporated.
Visual acuity outcomes in eyes with flat corneas after PRK.
Varssano, David; Waisbourd, Michael; Minkev, Liza; Sela, Tzahi; Neudorfer, Meira; Binder, Perry S
2013-06-01
To evaluate the impact of corneal curvatures less than 35 diopters (D) after photorefractive keratectomy (PRK) on visual acuity outcomes. Visual acuity outcomes of 5,410 eyes that underwent PRK from January 2006 to November 2010 were retrospectively analyzed for the impact of postoperative corneal curvatures on visual outcomes. All procedures were performed on a single platform (Allegretto 200Hz excimer laser; Alcon Laboratories, Inc., Irvine, CA). Main outcome measures were postoperative corrected distance visual acuity (CDVA) and loss of CDVA. Corneas with a measured or a calculated postoperative flat meridian less than 35 D and those with a measured postoperative steep meridian less than 35 D had worse postoperative CDVA than corneas with meridians of either 35 D or more (P ≤ .021). However, the preoperative CDVA was worse in the flatter curvatures in all comparisons performed (P ≤ .024). Consequently, the measured or calculated meridian curvature had no effect on CDVA loss (P ≥ .074). Postoperative corneal keratometry values (flat and steep meridians) less than 35 D did not have a predictive effect on the risk of losing visual acuity following myopic PRK performed on the Allegretto 200Hz excimer laser. Copyright 2013, SLACK Incorporated.
Severe pigment dispersion after iris-claw phakic intraocular lens implantation.
Galvis, Virgilio; Carreño, Néstor I; Tello, Alejandro; Laiton, Andrea N
2017-12-01
A 23-year-old female patient presented 3 months after the implantation of an Artisan® phakic intraocular lens with a severe depigmentation of the iris and peripheral anterior synechiae. Explantation of the intraocular lens and goniosynechialysis were performed. Eleven months after the explantation appearance of the iris significantly improved. There was no loss of lines of corrected distance visual acuity. Severe pigment dispersion after the implantation of an Artisan® phakic intraocular lens may happen and may require explantation of the lens. Iris depigmentation may improve with time.
Shi, Yue; Queener, Hope M.; Marsack, Jason D.; Ravikumar, Ayeswarya; Bedell, Harold E.; Applegate, Raymond A.
2013-01-01
Dynamic registration uncertainty of a wavefront-guided correction with respect to underlying wavefront error (WFE) inevitably decreases retinal image quality. A partial correction may improve average retinal image quality and visual acuity in the presence of registration uncertainties. The purpose of this paper is to (a) develop an algorithm to optimize wavefront-guided correction that improves visual acuity given registration uncertainty and (b) test the hypothesis that these corrections provide improved visual performance in the presence of these uncertainties as compared to a full-magnitude correction or a correction by Guirao, Cox, and Williams (2002). A stochastic parallel gradient descent (SPGD) algorithm was used to optimize the partial-magnitude correction for three keratoconic eyes based on measured scleral contact lens movement. Given its high correlation with logMAR acuity, the retinal image quality metric log visual Strehl was used as a predictor of visual acuity. Predicted values of visual acuity with the optimized corrections were validated by regressing measured acuity loss against predicted loss. Measured loss was obtained from normal subjects viewing acuity charts that were degraded by the residual aberrations generated by the movement of the full-magnitude correction, the correction by Guirao, and optimized SPGD correction. Partial-magnitude corrections optimized with an SPGD algorithm provide at least one line improvement of average visual acuity over the full magnitude and the correction by Guirao given the registration uncertainty. This study demonstrates that it is possible to improve the average visual acuity by optimizing wavefront-guided correction in the presence of registration uncertainty. PMID:23757512
Fixating at far distance shortens reaction time to peripheral visual stimuli at specific locations.
Kokubu, Masahiro; Ando, Soichi; Oda, Shingo
2018-01-18
The purpose of the present study was to examine whether the fixation distance in real three-dimensional space affects manual reaction time to peripheral visual stimuli. Light-emitting diodes were used for presenting a fixation point and four peripheral visual stimuli. The visual stimuli were located at a distance of 45cm and at 25° in the left, right, upper, and lower directions from the sagittal axis including the fixation point. Near (30cm), Middle (45cm), Far (90cm), and Very Far (300cm) fixation distance conditions were used. When one of the four visual stimuli was randomly illuminated, the participants released a button as quickly as possible. Results showed that overall peripheral reaction time decreased as the fixation distance increased. The significant interaction between fixation distance and stimulus location indicated that the effect of fixation distance on reaction time was observed at the left, right, and upper locations but not at the lower location. These results suggest that fixating at far distance would contribute to faster reaction and that the effect is specific to locations in the peripheral visual field. The present findings are discussed in terms of viewer-centered representation, the focus of attention in depth, and visual field asymmetry related to neurological and psychological aspects. Copyright © 2017 Elsevier B.V. All rights reserved.
The Effect of Light Level and Small Pupils on Presbyopic Reading Performance.
Xu, Renfeng; Gil, Daniel; Dibas, Mohammed; Hare, William; Bradley, Arthur
2016-10-01
To examine the impact of small pupils and light levels on reading performance of distance-corrected presbyopes. To determine whether small pupils would enable presbyopes to read at near even at low light levels. To establish the lower range of text luminances, we quantified the space-averaged luminance of text in nine different artificially lit interior environments, and examined the impact of the text characters on space-averaged luminance of electronic and printed displays. Distance and near reading speeds of 20 presbyopes (ages 40-60 years) were measured while viewing through artificial pupils (diameters 1-4.5 mm), natural pupils, or with a multifocal contact lens. Space-averaged text luminance levels varied from 0.14 to 140 cd/m2 (including the range of measured environmental text luminances). Adding black text to a white computer display or paper reduces luminance by approximately 15% to 31%, and the lowest encountered environmental text luminance was approximately 2 to 3 cd/m2. For both distance and near reading performance, the 2- to 3-mm small pupil yielded the best overall reading acuity for space-averaged text light levels ≥ 2 cd/m2. The 2- to 3-mm artificial pupils and the multifocal contact lenses both enabled maximum or near-maximum reading speeds for 0.5 logMAR characters at distance and near, but with natural pupils, reading speeds were significantly reduced at near. Although photon noise at low luminance reduces the visual benefits of small pupils, the benefits of 2- to 3-mm artificial pupils are sufficient to enable >80% of distance-corrected presbyopes to read proficiently at near, even at the lowest text luminances found in interior environments.
Visual functions and disability in diabetic retinopathy patients
Shrestha, Gauri Shankar; Kaiti, Raju
2013-01-01
Purpose This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. Method A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. Result The majority of subjects (42.1%) were of the age group 60–70 years. Best corrected visual acuity was found to be 0.73 ± 0.2 in the better eye and 0.93 ± 0.27 in the worse eye, which was significantly different at p = 0.002. Visual disability scores were significantly higher for legibility of letters (1.2 ± 0.3) and sentences (1.4 ± 0.4), and least for clothing (0.7 ± 0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Conclusion Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. PMID:24646899
Visual functions and disability in diabetic retinopathy patients.
Shrestha, Gauri Shankar; Kaiti, Raju
2014-01-01
This study was undertaken to find correlations between visual functions and visual disabilities in patients with diabetic retinopathy. A cross-sectional study was carried out among 38 visually impaired diabetic retinopathy subjects at the Low Vision Clinic of B.P. Koirala Lions Centre for Ophthalmic Studies, Kathmandu. The subjects underwent assessment of distance and near visual acuity, objective and subjective refraction, contrast sensitivity, color vision, and central and peripheral visual fields. The visual disabilities of each subject in their daily lives were evaluated using a standard questionnaire. Multiple regression analysis between visual functions and visual disabilities index was assessed. The majority of subjects (42.1%) were of the age group 60-70 years. Best corrected visual acuity was found to be 0.73±0.2 in the better eye and 0.93±0.27 in the worse eye, which was significantly different at p=0.002. Visual disability scores were significantly higher for legibility of letters (1.2±0.3) and sentences (1.4±0.4), and least for clothing (0.7±0.3). Visual disability index for legibility of letters and sentences was significantly correlated with near visual acuity and peripheral visual field. Contrast sensitivity was also significantly correlated with the visual disability index, and total scores. Impairment of near visual acuity, contrast sensitivity, and peripheral visual field correlated significantly with different types of visual disability. Hence, these clinical tests should be an integral part of the visual assessment of diabetic eyes. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.
Photorefractive keratectomy in young Asian aviators with low-moderate myopia.
See, Brian; Tan, Marcus; Chia, Sin Eng; Gan, Wee Hoe; Low, Robin; Nah, Gerard
2014-01-01
The high prevalence of myopia among Asians led the Republic of Singapore Air Force (RSAF) to introduce photorefractive keratectomy (PRK) as a means of enlarging its pilot recruitment pool at the end of 2005. This study aims to address the efficacy and safety of PRK performed on young Asian patients with low-moderate myopia, as well as audit the RSAF's corneal refractive surgery (CRS) program. This is a retrospective case series of 149 eyes of 76 consecutive patients that underwent PRK as part of the RSAF CRS program over the 5-yr period from 1 January 2006 to 31 December 2010. The median patient age was 21 yr (range, 18-26 yr) and the mean preoperative spherical equivalent (SE) refraction was -3.39 - 1.19 D. Of the patients, 96.1% were men and all were of Asian origin. At the 12-mo follow-up, 98.5% of eyes had an uncorrected distance visual acuity (UDVA) of < or = 0.00 LogMAR, 100.0% of eyes had an SE refraction of within + 0.50 D of intended correction, and 2.300% of eyes had a loss of corrected distance visual acuity (CDVA) of 0.20 LogMAR. The cumulative incidence of retreatments was 6.7% and cumulative incidence of grade II or worse corneal haze requiring retreatment was 6.0%. Refractive stability was achieved at 3 mo postsurgery. The results of this study suggest that PRK performed within the context of a stringent and structured CRS program on young Asian eyes with low-moderate myopia is both efficacious and safe, with refractive stability achieved by 3 mo.
Patient-reported outcomes 5 years after laser in situ keratomileusis.
Schallhorn, Steven C; Venter, Jan A; Teenan, David; Hannan, Stephen J; Hettinger, Keith A; Pelouskova, Martina; Schallhorn, Julie M
2016-06-01
To assess vision-related, quality-of-life outcomes 5 years after laser in situ keratomileusis (LASIK) and determine factors predictive of patient satisfaction. Optical Express, Glasgow, Scotland. Retrospective case series. Data from patients who had attended a clinical examination 5 years after LASIK were analyzed. All treatments were performed using the Visx Star S4 IR excimer laser. Patient-reported satisfaction, the effect of eyesight on various activities, visual phenomena, and ocular discomfort were evaluated 5 years postoperatively. Multivariate regression analysis was performed to determine factors affecting patient satisfaction. The study comprised 2530 patients (4937 eyes) who had LASIK. The mean age at the time of surgery was 42.4 years ± 12.5 (SD), and the preoperative manifest spherical equivalent ranged from -11.0 diopters (D) to +4.88 D. Five years postoperatively, 79.3% of eyes were within ±0.50 D of emmetropia and 77.7% of eyes achieved monocular uncorrected distance visual acuity (UDVA) and 90.6% of eyes achieved binocular UDVA of 20/20 or better. Of the patients, 91.0% said they were satisfied with their vision and 94.9% did not wear distance correction. Less than 2.0% of patients noticed visual phenomena, even with spectacle correction. Major predictors of patient satisfaction 5 years postoperatively were postoperative binocular UDVA (37.6% variance explained by regression model), visual phenomena (relative contribution of 15.0%), preoperative and postoperative sphere and their interactions (11.6%), and eyesight-related difficulties with various activities such as night driving, outdoor activities, and reading (10.2%). Patient-reported quality-of-life and satisfaction rates remained high 5 years after LASIK. Uncorrected vision was the strongest predictor of satisfaction. Dr. S.C. Schallhorn is a consultant to Abbott Medical Optics, Inc., Zeiss Meditec AG, and Autofocus Inc. and a global medical director for Optical Express. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Bruno, Andrew E.; Ruby, Amanda M.; Luft, Joseph R.; Grant, Thomas D.; Seetharaman, Jayaraman; Montelione, Gaetano T.; Hunt, John F.; Snell, Edward H.
2014-01-01
Many bioscience fields employ high-throughput methods to screen multiple biochemical conditions. The analysis of these becomes tedious without a degree of automation. Crystallization, a rate limiting step in biological X-ray crystallography, is one of these fields. Screening of multiple potential crystallization conditions (cocktails) is the most effective method of probing a proteins phase diagram and guiding crystallization but the interpretation of results can be time-consuming. To aid this empirical approach a cocktail distance coefficient was developed to quantitatively compare macromolecule crystallization conditions and outcome. These coefficients were evaluated against an existing similarity metric developed for crystallization, the C6 metric, using both virtual crystallization screens and by comparison of two related 1,536-cocktail high-throughput crystallization screens. Hierarchical clustering was employed to visualize one of these screens and the crystallization results from an exopolyphosphatase-related protein from Bacteroides fragilis, (BfR192) overlaid on this clustering. This demonstrated a strong correlation between certain chemically related clusters and crystal lead conditions. While this analysis was not used to guide the initial crystallization optimization, it led to the re-evaluation of unexplained peaks in the electron density map of the protein and to the insertion and correct placement of sodium, potassium and phosphate atoms in the structure. With these in place, the resulting structure of the putative active site demonstrated features consistent with active sites of other phosphatases which are involved in binding the phosphoryl moieties of nucleotide triphosphates. The new distance coefficient, CDcoeff, appears to be robust in this application, and coupled with hierarchical clustering and the overlay of crystallization outcome, reveals information of biological relevance. While tested with a single example the potential applications related to crystallography appear promising and the distance coefficient, clustering, and hierarchal visualization of results undoubtedly have applications in wider fields. PMID:24971458
Kocamış, Sücattin İlker; Çakmak, Hasan Basri; Gerçeker, Sıdıka; Çağıl, Nurullah
2017-01-01
To investigate and compare the long-term safety, efficacy, and accuracy of PRK (photorefractive keratectomy) and LASEK (laser epithelial keratomileusis) in myopic corneas having residual corneal thickness less than 400 micron meters (µm). The medical reports of the patients who had undergone excimer laser surface ablation between 2007-2011 and had a residual corneal thickness less than 400 µm were retrospectively reviewed. Forty-two eyes of 42 patients with a mean age of 28.79±7.76 years were enrolled into the study. Twenty-two PRK and 20 LASEK procedures were performed. The mean follow-up time was 45.00±11.80 months. At the end of follow-up, no ectasia was detected. Nineteen percent of eyes had trace haze. No eyes lost any lines in corrected distance visual acuity. Eighty-one percent of the patients had an uncorrected distance visual acuity better than 20/40. The regression rate was 16.7%. Sixty-two percent of eyes were within ±1.00 D. The safety and efficacy indexes were 1.19±0.42 and 1.00±0.40, respectively. There was not any difference between LASEK and PRK regarding achieved spherical equivalent refraction, haze ratio, visual acuity, safety, efficacy, and regression. Both PRK and LASEK are safe and effective in myopic corneas having thin residual thickness.
Grids in topographic maps reduce distortions in the recall of learned object locations.
Edler, Dennis; Bestgen, Anne-Kathrin; Kuchinke, Lars; Dickmann, Frank
2014-01-01
To date, it has been shown that cognitive map representations based on cartographic visualisations are systematically distorted. The grid is a traditional element of map graphics that has rarely been considered in research on perception-based spatial distortions. Grids do not only support the map reader in finding coordinates or locations of objects, they also provide a systematic structure for clustering visual map information ("spatial chunks"). The aim of this study was to examine whether different cartographic kinds of grids reduce spatial distortions and improve recall memory for object locations. Recall performance was measured as both the percentage of correctly recalled objects (hit rate) and the mean distance errors of correctly recalled objects (spatial accuracy). Different kinds of grids (continuous lines, dashed lines, crosses) were applied to topographic maps. These maps were also varied in their type of characteristic areas (LANDSCAPE) and different information layer compositions (DENSITY) to examine the effects of map complexity. The study involving 144 participants shows that all experimental cartographic factors (GRID, LANDSCAPE, DENSITY) improve recall performance and spatial accuracy of learned object locations. Overlaying a topographic map with a grid significantly reduces the mean distance errors of correctly recalled map objects. The paper includes a discussion of a square grid's usefulness concerning object location memory, independent of whether the grid is clearly visible (continuous or dashed lines) or only indicated by crosses.
Hatch, Bryndon B; Moshirfar, Majid; Ollerton, Andrew J; Sikder, Shameema; Mifflin, Mark D
2011-01-01
To compare differences in visual acuity, contrast sensitivity, complications, and higher-order ocular aberrations (HOAs) in eyes with stable myopia undergoing either photo-refractive keratectomy (PRK) or thin-flap laser in situ keratomileusis (LASIK) (intended flap thickness of 90 μm) using the VISX Star S4 CustomVue excimer laser and the IntraLase FS60 femtosecond laser at 1, 3, and 6 months postoperatively. In this prospective, masked, and randomized pilot study, refractive surgery was performed contralaterally on 52 eyes: 26 with PRK and 26 with thin-flap LASIK. Primary outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, and complications. At 6 months, mean values for UDVA (logMAR) were -0.043 ± 0.668 and -0.061 ± 0.099 in the PRK and thin-flap LASIK groups, respectively (n = 25, P = 0.466). UDVA of 20/20 or better was achieved in 96% of eyes undergoing PRK and 92% of eyes undergoing thin-flap LASIK, whereas 20/15 vision or better was achieved in 73% of eyes undergoing PRK and 72% of eyes undergoing thin-flap LASIK (P > 0.600). Significant differences were not found between treatment groups in contrast sensitivity (P ≥ 0.156) or CDVA (P = 0.800) at postoperative 6 months. Types of complications differed between groups, notably 35% of eyes in the thin-flap LASIK group experiencing complications, including microstriae and 2 flap tears. Under well-controlled surgical conditions, PRK and thin-flap LASIK refractive surgeries achieve similar results in visual acuity, contrast sensitivity, and induction of HOAs, with differences in experienced complications.
Hatch, Bryndon B; Moshirfar, Majid; Ollerton, Andrew J; Sikder, Shameema; Mifflin, Mark D
2011-01-01
Purpose: To compare differences in visual acuity, contrast sensitivity, complications, and higher-order ocular aberrations (HOAs) in eyes with stable myopia undergoing either photo-refractive keratectomy (PRK) or thin-flap laser in situ keratomileusis (LASIK) (intended flap thickness of 90 μm) using the VISX Star S4 CustomVue excimer laser and the IntraLase FS60 femtosecond laser at 1, 3, and 6 months postoperatively. Methods: In this prospective, masked, and randomized pilot study, refractive surgery was performed contralaterally on 52 eyes: 26 with PRK and 26 with thin-flap LASIK. Primary outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), contrast sensitivity, and complications. Results: At 6 months, mean values for UDVA (logMAR) were −0.043 ± 0.668 and −0.061 ± 0.099 in the PRK and thin-flap LASIK groups, respectively (n = 25, P = 0.466). UDVA of 20/20 or better was achieved in 96% of eyes undergoing PRK and 92% of eyes undergoing thin-flap LASIK, whereas 20/15 vision or better was achieved in 73% of eyes undergoing PRK and 72% of eyes undergoing thin-flap LASIK (P > 0.600). Significant differences were not found between treatment groups in contrast sensitivity (P ≥ 0.156) or CDVA (P = 0.800) at postoperative 6 months. Types of complications differed between groups, notably 35% of eyes in the thin-flap LASIK group experiencing complications, including microstriae and 2 flap tears. Conclusion: Under well-controlled surgical conditions, PRK and thin-flap LASIK refractive surgeries achieve similar results in visual acuity, contrast sensitivity, and induction of HOAs, with differences in experienced complications. PMID:21573091
Ting, Darren Shu Jeng; Danjoux, Jean-Pierre
2018-05-12
To report three cases of late-onset (7-14 years postoperative) traumatic dislocation of laser in situ keratomileusis (LASIK) flaps with epithelial ingrowth that all had delayed surgical intervention. A retrospective, interventional case series of three patients who underwent flap repositioning and mechanical debridement of epithelial ingrowth, all after an initial delayed diagnosis/treatment of dislocated LASIK flap. Visual improvement was noted in all three cases following LASIK flap repositioning and debridement of epithelial ingrowth; patient 1 improved from 20/800 corrected-distance-visual-acuity (CDVA) to 20/20 uncorrected-distance-visual-acuity (UDVA) postoperative (14 years post-LASIK, 5-week interval between injury and surgery), patient 2 improved from 20/50 CDVA to 20/20 CDVA (10 years post-LASIK, 4-month interval between injury and surgery) and patient 3 improved from 20/80 CDVA to 20/60 CDVA (7 years post-LASIK, 14-month interval between injury and surgery). Flap dislocation was not suspected or diagnosed in two patients during the first ophthalmic visit. Postoperative visual outcome was not influenced by the presenting vision but might be negatively affected by the delay in surgical intervention, the presence of preoperative central epithelial ingrowth and postoperative striae. This case series reported one of the longest documented intervals between LASIK and traumatic dislocation of LASIK flap with secondary epithelial ingrowth. Delayed diagnosis and management of flap dislocation after corneal trauma may potentially increase the risk of epithelial ingrowth, recalcitrant flap striae and visual impairment. The presence of late-onset epithelial ingrowth in patients with previous LASIK mandates careful examination for occult flap displacement.
Ghoreishi, Mohammad; Naderi Beni, Afsaneh; Naderi Beni, Zahra; Zandi, Alireza; Kianersi, Farzan
2017-12-01
The purpose of this study is to compare visual outcomes of myopic refractive surgery, using tissue saving (TS), a standard ablation profile by a Technolas 217z100, and aberration smart ablation (ASA), an aspheric algorithm by a MEL 80 excimer laser in two eyes of one patient. In this prospective interventional paired-eye controlled study, a total of 100 eyes of 50 participants with myopia with or without astigmatism underwent thin-flap Femto-LASIK, using a Femto LDV femtosecond laser (Ziemer Ophthalmic Systems AG, Port, Switzerland). For each patient, one eye was randomly treated with tissue-saving algorithm (TS group) by the Technolas 217z100 excimer laser and the other eye was treated with optimized smart ablation profile (ASA group) by the MEL 80 excimer laser. Outcome measures were uncorrected distance visual acuities (UDVAs), corrected distance visual acuities (CDVAs), manifest refraction, higher-order aberrations (HOAs), contrast sensitivity, and patient satisfaction 12 months after surgery. At 12 months postoperative, "45 subjects returned with mean" UDVA was - 0.02 ± 0.08 Logarithm of mean angle of resolution (LogMAR) for TS group and - 0.02 ± 0.09 LogMAR for ASA group (P = 0.91). Of the TS eyes, 42/45 (93.3%) and 32/45 (71.1%) were within ± 0.5 D and ± 0.25 D of target refraction, respectively, and of the ASA eyes, 41/45 (91.1%) and 30/45 (66.6%) were within ± 0.5 D and ± 0.25 D of target refraction, respectively. No statistically significant differences were observed between groups in HOAs changes and contrast sensitivity function. Aspheric and non-aspheric LASIKs using the two different excimer lasers provide similar results in myopic and myopic astigmatism patients.
Prakash, Gaurav; Agarwal, Amar; Kumar, Dhivya Ashok; Jacob, Soosan; Agarwal, Athiya; Maity, Amrita
2011-03-01
To evaluate the visual and refractive outcomes and expected benefits of Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking. This prospective, interventional case series comprised 122 eyes (70 patients). Pre- and postoperative assessment included uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refraction, and higher order aberrations. All patients underwent Tissue Saving Treatment algorithm-guided surface ablation with iris recognition and dynamic rotational eye tracking using the Technolas 217z 100-Hz excimer platform (Technolas Perfect Vision GmbH). Follow-up was performed up to 6 months postoperatively. Theoretical benefit analysis was performed to evaluate the algorithm's outcomes compared to others. Preoperative spherocylindrical power was sphere -3.62 ± 1.60 diopters (D) (range: 0 to -6.75 D), cylinder -1.15 ± 1.00 D (range: 0 to -3.50 D), and spherical equivalent -4.19 ± 1.60 D (range: -7.75 to -2.00 D). At 6 months, 91% (111/122) of eyes were within ± 0.50 D of attempted correction. Postoperative UDVA was comparable to preoperative CDVA at 1 month (P=.47) and progressively improved at 6 months (P=.004). Two eyes lost one line of CDVA at 6 months. Theoretical benefit analysis revealed that of 101 eyes with astigmatism, 29 would have had cyclotorsion-induced astigmatism of ≥ 10% if iris recognition and dynamic rotational eye tracking were not used. Furthermore, the mean percentage decrease in maximum depth of ablation by using the Tissue Saving Treatment was 11.8 ± 2.9% over Aspheric, 17.8 ± 6.2% over Personalized, and 18.2 ± 2.8% over Planoscan algorithms. Tissue saving surface ablation with iris recognition and dynamic rotational eye tracking was safe and effective in this series of eyes. Copyright 2011, SLACK Incorporated.
Clinical Performance of a New Bitangential Mini-scleral Lens.
Otten, Henny M; van der Linden, Bart J J J; Visser, Esther-Simone
2018-06-01
New bitangential mini-scleral lens designs provide a highly precise fit, follow the scleral shape, are comfortable to wear, and can correct residual astigmatism. This new scleral lens design complements the arsenal of medical contact lenses available to eye care practitioners. The aim of this study was to evaluate the subjective and objective performance of a new mini-scleral lens design with a bitangential periphery. In this observational study, data were collected for up to 15 months (median, 84 days; interquartile range, 76 days) from the left eyes of 133 patients fitted with this newly designed lens. Data were recorded during regular visits at Visser Contact Lens Practice's scleral lens clinics: diagnosis, clinical indication for scleral lenses, previous contact lens type, subjective performance, horizontal visible iris diameter, corrected distance visual acuity, and scleral lens fitting characteristics. The most common indication was keratoconus (45%), followed by irregular astigmatism (22%), keratoplasty (16.5%), ocular surface disease (13.5%), and other forms of irregular astigmatism (3%). The majority of patients (79%) scored comfort as either a 4 or 5 (out of 5), and 82% wore their lenses 12 hours or longer a day. Most lenses (81%) had a diameter of 16 mm (median, 16 mm; range, 15.5 to 17 mm) and were composed of Boston XO2 (46%), Menicon Z (44%), Boston XO (9%), or Boston Equalens II (1%). The median corrected distance visual acuity was 0.022 logarithm of the minimal angle of resolution (interquartile range, 0.155). The fitting characteristics revealed optimal values for centration and movement in 91% and 83%, respectively. Finally, the median stabilization axis was 50 degrees. New mini-scleral lenses with bitangential peripheral geometry yield satisfactory clinical results and good subjective performance and are therefore an effective option for managing patients who have irregular astigmatism or other corneal pathology.
Niparugs, Muanploy; Tananuvat, Napaporn; Chaidaroon, Winai; Tangmonkongvoragul, Chulaluck; Ausayakhun, Somsanguan
2018-01-01
Purpose: To evaluate the efficacy, predictability, stability and safety of laser in situ keratomileusis (LASIK) using the FS200 femtosecond laser and EX500 excimer laser platform. Methods: The outcomes of 254 eyes of 129 consecutive patients with myopia or myopic astigmatism who underwent full correction femtosecond laser-assisted LASIK at CMU LASIK Center were assessed. Pre-operative and post-operative parameters including manifest refraction, Uncorrected Distance Visual Acuity (UDVA), Best Corrected Distance Visual Acuity (BDVA), corneal topography and tomography were analyzed. The results between low to moderate myopia and high myopia were compared up to 12 months. Results: Mean pre-operative Spherical Equivalent (SE) was -5.15±2.41 Diopters (D) (range -0.50 to -11.50 D) and -0.13±0.28 D, -0.13±0.27 D, -0.13±0.28 D and -0.14±0.30 D at 1, 3, 6, and 12 months, post-operatively. At 12 months, the propor¬tion of eyes achieving UDVA ≥ 20/20 was 90.0% and ≥20/40 was 98.8%. The proportion of eyes achieving post-operative mean SE ±0.5 D, and ±1 D was 91.3%, and 98.5%. No eyes lost more than two lines of BDVA. The low to moderate myopic group had a statistically significant better UDVA at one (p=0.017) and three months (p=0.014) but no difference at six (p=0.061) and 12 months (p=0.091). The mean post-operative SE was better in low to moderate myopic group at every follow-up visit (p=0.001, 0.007, <0.001 and <0.001). Conclusion: One-year clinical results of LASIK with the FS200 femtosecond laser and EX500 excimer laser showed high efficacy, predictability, stability and safety. PMID:29872485
Brito, Pedro; Salgado-Borges, José; Neves, Helena; Gonzalez-Meijome, José; Monteiro, Manuel
2015-03-01
To study the perception of light distortion after refractive lens exchange (RLE) with diffractive multifocal intraocular lenses (IOLs). Clínica Oftalmológica das Antas, Porto, Portugal. Retrospective comparative study. Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P = .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Visual acuity and legal visual requirement to drive a passenger vehicle.
Kiel, A W; Butler, T; Alwitry, A
2003-07-01
(1). To test the consistency and ease with which number-plates of different component figures can be read under DVLA driving test conditions; (2). to test the relative difficulty of reading corresponding figures on registration plates of white and yellow backgrounds.Design Prospective study of consecutive eligible clinic patients. Ophthalmology outpatients. 210 individuals with a corrected visual acuity with both eyes open of between 6/9 and 6/12. The ability to read three different number-plates under standard DVLA driving-test conditions (ie at 20.5 m in good daylight with glasses if worn) and the ability to read identical number-plates against a white and a yellow background. There is a significant difference between the ease with which three different number-plates can be read depending on their letter and numeral composition, although this did not seem to be significantly affected by whether they were printed on a yellow or white background. Only 92.3% of subjects could read all the number-plates at the legal distance, 96.7% could read at least one number-plate at the legal distance and 3.3% of the test subjects could not read any of the number-plates at 20.5 m. The current test protocol used to obtain a driving licence and, moreover, the test the police will employ to assess visual competence to drive, is highly variable and is unlikely to give consistent repeatable results. The performance of those with equally good visual acuity is unpredictable and is highly dependent on the number-plate they are asked to read. This variability could exclude some who would otherwise pass the test or pass an individual with a visual acuity below accepted standards. The forthcoming changes in the regulations for design of number-plates is an ideal opportunity to standardise the whole testing procedure for driving visual acuity.
Optical performance of multifocal soft contact lenses via a single-pass method.
Bakaraju, Ravi C; Ehrmann, Klaus; Falk, Darrin; Ho, Arthur; Papas, Eric
2012-08-01
A physical model eye capable of carrying soft contact lenses (CLs) was used as a platform to evaluate optical performance of several commercial multifocals (MFCLs) with high- and low-add powers and a single-vision control. Optical performance was evaluated at three pupil sizes, six target vergences, and five CL-correcting positions using a spatially filtered monochromatic (632.8 nm) light source. The various target vergences were achieved by using negative trial lenses. A photosensor in the retinal plane recorded the image point-spread that enabled the computation of visual Strehl ratios. The centration of CLs was monitored by an additional integrated en face camera. Hydration of the correcting lens was maintained using a humidity chamber and repeated instillations of rewetting saline drops. All the MFCLs reduced performance for distance but considerably improved performance along the range of distance to near target vergences, relative to the single-vision CL. Performance was dependent on add power, design, pupil, and centration of the correcting CLs. Proclear (D) design produced good performance for intermediate vision, whereas Proclear (N) design performed well at near vision (p < 0.05). AirOptix design exhibited good performance for distance and intermediate vision. PureVision design showed improved performance across the test vergences, but only for pupils ≥4 mm in diameter. Performance of Acuvue bifocal was comparable with other MFCLs, but only for pupils >4 mm in diameter. Acuvue Oasys bifocal produced performance comparable with single-vision CL for most vergences. Direct measurement of single-pass images at the retinal plane of a physical model eye used in conjunction with various MFCLs is demonstrated. This method may have utility in evaluating the relative effectiveness of commercial and prototype designs.
Visual Acuity Using Head-fixed Displays During Passive Self and Surround Motion
NASA Technical Reports Server (NTRS)
Wood, Scott J.; Black, F. Owen; Stallings, Valerie; Peters, Brian
2007-01-01
The ability to read head-fixed displays on various motion platforms requires the suppression of vestibulo-ocular reflexes. This study examined dynamic visual acuity while viewing a head-fixed display during different self and surround rotation conditions. Twelve healthy subjects were asked to report the orientation of Landolt C optotypes presented on a micro-display fixed to a rotating chair at 50 cm distance. Acuity thresholds were determined by the lowest size at which the subjects correctly identified 3 of 5 optotype orientations at peak velocity. Visual acuity was compared across four different conditions, each tested at 0.05 and 0.4 Hz (peak amplitude of 57 deg/s). The four conditions included: subject rotated in semi-darkness (i.e., limited to background illumination of the display), subject stationary while visual scene rotated, subject rotated around a stationary visual background, and both subject and visual scene rotated together. Visual acuity performance was greatest when the subject rotated around a stationary visual background; i.e., when both vestibular and visual inputs provided concordant information about the motion. Visual acuity performance was most reduced when the subject and visual scene rotated together; i.e., when the visual scene provided discordant information about the motion. Ranges of 4-5 logMAR step sizes across the conditions indicated the acuity task was sufficient to discriminate visual performance levels. The background visual scene can influence the ability to read head-fixed displays during passive motion disturbances. Dynamic visual acuity using head-fixed displays can provide an operationally relevant screening tool for visual performance during exposure to novel acceleration environments.
Neural basis of forward flight control and landing in honeybees.
Ibbotson, M R; Hung, Y-S; Meffin, H; Boeddeker, N; Srinivasan, M V
2017-11-06
The impressive repertoire of honeybee visually guided behaviors, and their ability to learn has made them an important tool for elucidating the visual basis of behavior. Like other insects, bees perform optomotor course correction to optic flow, a response that is dependent on the spatial structure of the visual environment. However, bees can also distinguish the speed of image motion during forward flight and landing, as well as estimate flight distances (odometry), irrespective of the visual scene. The neural pathways underlying these abilities are unknown. Here we report on a cluster of descending neurons (DNIIIs) that are shown to have the directional tuning properties necessary for detecting image motion during forward flight and landing on vertical surfaces. They have stable firing rates during prolonged periods of stimulation and respond to a wide range of image speeds, making them suitable to detect image flow during flight behaviors. While their responses are not strictly speed tuned, the shape and amplitudes of their speed tuning functions are resistant to large changes in spatial frequency. These cells are prime candidates not only for the control of flight speed and landing, but also the basis of a neural 'front end' of the honeybee's visual odometer.
Güell, Jose L; Verdaguer, Paula; Elies, Daniel; Gris, Oscar; Manero, Felicidad
2014-04-01
To present a case of a late, deep stromal scar in a 22-year-old patient with forme fruste keratoconus who underwent combined corneal cross-linking and photorefractive keratectomy (PRK). Topography-guided corneal cross-linking combined with corneal PRK (without complications) was performed in both eyes with a delay of 2 weeks between each eye. At the 5-month postoperative examination of the right eye, a localized corneal haze was circumscribed to the posterior deep stroma, signifying a decrease of visual acuity. However, this improved partially and temporarily when treated with topical corticoids during 2 years of follow-up and then reoccurred, affecting the corrected distance visual acuity. To the authors' knowledge, this is the first documented, clinical case presenting a deep stromal affectation without endothelial decompensation and visual acuity affectation as a postoperative complication following topography-guided PRK and corneal cross-linking. Copyright 2014, SLACK Incorporated.
Relation Between Near Work and Myopia Progression in Student Population
Muhamedagic, Lejla; Muhamedagic, Belma; Halilovic, Emina Alimanovic; Halimic, Jasmina Alajbegovic; Stankovic, Aleksa; Muracevic, Bedrana
2014-01-01
Aim To determine relation between near work and myopia progression in student population. Causes of myopia occurrence are not sufficiently explained. Methods This retrospective-prospective, descriptive research included 100 students with verified myopia up to -3 Dsph. Ophthalmological examination and measurement diopter-hours variable (Dh) were done twice, in the period from January 2011 until January 2012. Results A multivariate regression analysis of impact on the difference of distance visual acuity without correction to the right and left eye and difference of automatic computer refractometry in cycloplegia of both eyes indicates that, diopter-hours variable (Dh) had statistically significant impact on increase of distance visual acuity difference (right eye OR: I measurement–Dh 1.489, II measurement–Dh 1.544, p<0.05; left eye OR: I measurement–Dh 1.602, II measurement–Dh 1.538, p<0.05) and automatic computer refractometry in cycloplegia (right eye OR: I measurement 1.361, II measurement 1.493, p<0.05; left eye OR: I measurement 0.931, II measurement 1.019, p<0.05) during both measurements. Conclusion Near work cause the increase of myopia. This research opened a perspective for other researches on the impact of near work on myopia. PMID:24944532
The role of vision in auditory distance perception.
Calcagno, Esteban R; Abregú, Ezequiel L; Eguía, Manuel C; Vergara, Ramiro
2012-01-01
In humans, multisensory interaction is an important strategy for improving the detection of stimuli of different nature and reducing the variability of response. It is known that the presence of visual information affects the auditory perception in the horizontal plane (azimuth), but there are few researches that study the influence of vision in the auditory distance perception. In general, the data obtained from these studies are contradictory and do not completely define the way in which visual cues affect the apparent distance of a sound source. Here psychophysical experiments on auditory distance perception in humans are performed, including and excluding visual cues. The results show that the apparent distance from the source is affected by the presence of visual information and that subjects can store in their memory a representation of the environment that later improves the perception of distance.
NASA Astrophysics Data System (ADS)
Braun, Jaroslav; Štroner, Martin; Urban, Rudolf
2015-05-01
All surveying instruments and their measurements suffer from some errors. To refine the measurement results, it is necessary to use procedures restricting influence of the instrument errors on the measured values or to implement numerical corrections. In precise engineering surveying industrial applications the accuracy of the distances usually realized on relatively short distance is a key parameter limiting the resulting accuracy of the determined values (coordinates, etc.). To determine the size of systematic and random errors of the measured distances were made test with the idea of the suppression of the random error by the averaging of the repeating measurement, and reducing systematic errors influence of by identifying their absolute size on the absolute baseline realized in geodetic laboratory at the Faculty of Civil Engineering CTU in Prague. The 16 concrete pillars with forced centerings were set up and the absolute distances between the points were determined with a standard deviation of 0.02 millimetre using a Leica Absolute Tracker AT401. For any distance measured by the calibrated instruments (up to the length of the testing baseline, i.e. 38.6 m) can now be determined the size of error correction of the distance meter in two ways: Firstly by the interpolation on the raw data, or secondly using correction function derived by previous FFT transformation usage. The quality of this calibration and correction procedure was tested on three instruments (Trimble S6 HP, Topcon GPT-7501, Trimble M3) experimentally using Leica Absolute Tracker AT401. By the correction procedure was the standard deviation of the measured distances reduced significantly to less than 0.6 mm. In case of Topcon GPT-7501 is the nominal standard deviation 2 mm, achieved (without corrections) 2.8 mm and after corrections 0.55 mm; in case of Trimble M3 is nominal standard deviation 3 mm, achieved (without corrections) 1.1 mm and after corrections 0.58 mm; and finally in case of Trimble S6 is nominal standard deviation 1 mm, achieved (without corrections) 1.2 mm and after corrections 0.51 mm. Proposed procedure of the calibration and correction is in our opinion very suitable for increasing of the accuracy of the electronic distance measurement and allows the use of the common surveying instrument to achieve uncommonly high precision.
Calibrating Reach Distance to Visual Targets
ERIC Educational Resources Information Center
Mon-Williams, Mark; Bingham, Geoffrey P.
2007-01-01
The authors investigated the calibration of reach distance by gradually distorting the haptic feedback obtained when participants grasped visible target objects. The authors found that the modified relationship between visually specified distance and reach distance could be captured by a straight-line mapping function. Thus, the relation could be…
Foldable iris-fixated intraocular lens implantation in children.
Ryan, Andrea; Hartnett, Claire; Lanigan, Bernadette; O'Keefe, Michael
2012-09-01
To describe the results of foldable iris-fixated intraocular lens (IOL) implantation in children. Children with high bilateral or unilateral myopia who were intolerant of spectacle or contact lens correction were implanted with an iris-fixated foldable IOL and prospectively followed. We measured pre- and postoperative visual acuity, refraction, endothelial cell density (ECD) and National Eye Institute Visual Functioning Questionnaire-25. Eleven eyes of six children were implanted. Indications were high bilateral myopia in children with comorbid neurobehavioural disorders, high anisometropia and high myopic astigmatism. Mean preoperative spherical equivalent (SE) refraction was -14.6 dioptres (D)±4.2 SD. Mean follow-up was 15 months. Postoperative SE refraction was -2.40 D±2.40 SD. Corrected distance visual acuity (CDVA) improved from mean logMAR 0.84±0.4 SD to postoperative 0.67±0.34 SD (p=0.005). CDVA was reduced because of coexistent ocular disorders and amblyopia. Vision-related quality of life (QOL) measures improved significantly. There were no intraoperative or postoperative serious complications. Foldable iris-fixated IOL insertion can give a significant improvement in vision and in vision-related QOL in a subset of paediatric patients with special refractive needs who are intolerant to conventional treatment. Long-term follow-up is required for monitoring of ECD. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.
Sources of medical error in refractive surgery.
Moshirfar, Majid; Simpson, Rachel G; Dave, Sonal B; Christiansen, Steven M; Edmonds, Jason N; Culbertson, William W; Pascucci, Stephen E; Sher, Neal A; Cano, David B; Trattler, William B
2013-05-01
To evaluate the causes of laser programming errors in refractive surgery and outcomes in these cases. In this multicenter, retrospective chart review, 22 eyes of 18 patients who had incorrect data entered into the refractive laser computer system at the time of treatment were evaluated. Cases were analyzed to uncover the etiology of these errors, patient follow-up treatments, and final outcomes. The results were used to identify potential methods to avoid similar errors in the future. Every patient experienced compromised uncorrected visual acuity requiring additional intervention, and 7 of 22 eyes (32%) lost corrected distance visual acuity (CDVA) of at least one line. Sixteen patients were suitable candidates for additional surgical correction to address these residual visual symptoms and six were not. Thirteen of 22 eyes (59%) received surgical follow-up treatment; nine eyes were treated with contact lenses. After follow-up treatment, six patients (27%) still had a loss of one line or more of CDVA. Three significant sources of error were identified: errors of cylinder conversion, data entry, and patient identification error. Twenty-seven percent of eyes with laser programming errors ultimately lost one or more lines of CDVA. Patients who underwent surgical revision had better outcomes than those who did not. Many of the mistakes identified were likely avoidable had preventive measures been taken, such as strict adherence to patient verification protocol or rigorous rechecking of treatment parameters. Copyright 2013, SLACK Incorporated.
Tuwairqi, Waleed S; Sinjab, Mazen M
2012-05-01
To evaluate 1-year visual and topographic outcomes and safety and efficacy of corneal collagen cross-linking (CXL) combined with topography-guided photorefractive keratectomy (TG-PRK) to achieve near emmetropia in eyes with low-grade keratoconus. Twenty-two eyes from 15 patients (11 women, 4 men) were included in a prospective, nonrandomized, noncontrolled clinical study. Mean patient age was 26.6±6.07 years (range: 19 to 40 years). Inclusion criteria were low-grade keratoconus with evidence of progression, transparent cornea, corrected distance visual acuity (CDVA) 0.8 (decimal) or better, corneal thickness >440 μm, and maximum keratometry readings (K-max) <51.00 diopters (D). All patients underwent simultaneous TG-PRK with CXL. Study parameters were uncorrected distance visual acuity, CDVA, manifest refractive error, manifest and topographic (corneal) astigmatism, patient satisfaction, and efficacy and safety of the treatment. Follow-up was 1 year. After 1 year, statistically significant improvement was noted in all study parameters (P<.01). The safety and efficacy indices were 1.6 and 0.4, respectively. Patient satisfaction questionnaire showed that 91% were satisfied, 9% were not completely satisfied but believed they improved, and none were dissatisfied. Corneal topography demonstrated significant improvement in 55%, improvement in 36%, and minor improvement in 9% of cases. No cases progressed as evidenced by keratometry readings. Simultaneous TG-PRK with CXL is an effective and safe treatment with remarkable visual and topographic outcomes in patients with low-grade keratoconus who meet the recommended inclusion criteria. Copyright 2012, SLACK Incorporated.
Marmamula, Srinivas; Keeffe, Jill E; Rao, Gullapalli N
2009-01-01
To investigate the prevalence of uncorrected refractive errors, presbyopia and spectacle coverage in subjects aged 15-50 years using rapid assessment methodology in the Mahabubnagar district of Andhra Pradesh, India. A population-based cross sectional study was conducted using cluster random sampling to enumerate 3,300 subjects from 55 clusters. Unaided, aided and pinhole visual acuity was assessed using a LogMAR chart at a distance of 4 meters. Near vision was assessed using N notation chart. Uncorrected refractive error was defined as presenting visual acuity worse than 6/12 but improving to at least 6/12 or better on using a pinhole. Presbyopia is defined as binocular near vision worse than N8 in subjects aged more than 35 years with binocular distance visual acuity of 6/12 or better. Of the 3,300 subjects enumerated from 55 clusters, 3,203 (97%) subjects were available for examination. Of these, 1,496 (46.7%) were females and 930 (29%) were > or = 40 years. Age and gender adjusted prevalence of uncorrected refractive errors causing visual impairment in the better eye was 2.7% (95% CI, 2.1-3.2%). Presbyopia was present in 690 (63.7%, 95% CI, 60.8-66.6%) subjects aged over 35 years. Spectacle coverage for refractive error was 29% and for presbyopia it was 19%. There is a large unmet need for refractive correction in this area in India. Rapid assessment methods are an effective means of assessing the need for services and the impact of models of care.
Eccentric correction for off-axis vision in central visual field loss.
Gustafsson, Jörgen; Unsbo, Peter
2003-07-01
Subjects with absolute central visual field loss use eccentric fixation and magnifying devices to utilize their residual vision. This preliminary study investigated the importance of an accurate eccentric correction of off-axis refractive errors to optimize the residual visual function for these subjects. Photorefraction using the PowerRefractor instrument was used to evaluate the ametropia in eccentric fixation angles. Methods were adapted for measuring visual acuity outside the macula using filtered optotypes from high-pass resolution perimetry. Optical corrections were implemented, and the visual function of subjects with central visual field loss was measured with and without eccentric correction. Of the seven cases reported, five experienced an improvement in visual function in their preferred retinal locus with eccentric refraction. The main result was that optical correction for better image quality on the peripheral retina is important for the vision of subjects with central visual field loss, objectively as well as subjectively.
Tychsen, Lawrence; Faron, Nicholas; Hoekel, James
2017-03-01
A subset of children with high anisometropia or isoametropia and neurobehavioral disorders have chronic difficulties with spectacle or contact lens wear. We report the results of refractive surgery in a series of these children treated using bilateral or unilateral intraocular collamer lens (Visian ICL) implantation for moderate to high myopia. Prospective nonrandomized cohort study. Clinical course and outcome data were collated prospectively for 40 implanted eyes in 23 children (mean age 10.2 ± 5.3 years, range, 1.8-17 years). Myopia ranged from -3.0 to -14.5 diopters (D), mean -9.2 ± 3.5 D. Goal refraction was plano to +1 D. Correction was achieved by sulcus implantation of a Visian ICL (STAAR Surgical, Monrovia, California, USA) under general anesthesia. Mean follow-up was 15.1 months (range, 6-22 months). Thirty-five eyes (88%) were corrected to within ±1.0 D of goal refraction; the other 5 (12%) were corrected to within 1.5 D. Uncorrected distance visual acuity improved substantially in all eyes (from mean 20/1050 [logMAR 1.72] to mean 20/42 [logMAR 0.48]). Spherical regression at last follow-up was an average of +0.59 D. Visuomotor comorbidities (eg, amblyopia, nystagmus, foveopathy, optic neuropathy) accounted for residual postoperative subnormal visual acuity. Thirteen of the 23 children (57%) had a neurobehavioral disorder (eg, developmental delay/intellectual disability/mental retardation, Down syndrome, cerebral palsy, autism spectrum disorder). Eighty-five percent (11/13) of those children were reported to have enhanced visual awareness, attentiveness, or social interactions. Endothelial cell density was measureable in 6 cooperative children (10 eyes), showing an average 1% decline. Central corneal thickness, measured in all children, increased an average of 8 μm. Two children (8%) required unplanned return to the operating room on the first postoperative day to alleviate pupillary block caused by a nonpatent iridotomy. No other complications were encounterd. Visian ICL implantation improves visual function in special needs children who have moderate to high myopia and difficulties wearing glasses or contact lenses. Copyright © 2016 Elsevier Inc. All rights reserved.
Refractive Outcomes of 20 Eyes Undergoing ICL Implantation for Correction of Hyperopic Astigmatism.
Coskunseven, Efekan; Kavadarli, Isilay; Sahin, Onurcan; Kayhan, Belma; Pallikaris, Ioannis
2017-09-01
To analyze 1-week, 1-month, and 12-month postoperative refractive outcomes of eyes that under-went ICL implantation to correct hyperopic astigmatism. The study enrolled 20 eyes of patients with an average age of 32 years (range: 21 to 40 years). The outcomes of spherical and cylindrical refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), vault, and angle parameters were evaluated 1 week, 1 month, and 12 months postoperatively. The preoperative mean UDVA was 0.15 ± 0.11 (decimal) (20/133 Snellen) and increased to 0.74 ± 0.25 (20/27 Snellen) postoperatively, with a change of 0.59 (decimal) (20/33.9 Snellen) (P < .0001), which was statistically significant. The preoperative mean CDVA was 0.74 ± 0.25 (decimal) (20/27 Snellen) and increased to 0.78 ± 0.21 (20/25 Snellen), with a change of 0.03 (decimal) (20/666 Snellen) (P < .052), which was not statistically significant. The mean preoperative sphere was 6.86 ± 1.77 diopters (D) and the mean preoperative cylinder was -1.44 ± 0.88 D. The mean 12-month postoperative sphere decreased to 0.46 ± 0.89 D (P < .001) and cylinder decreased to -0.61 ± 0.46 D (P < .001), with a change of 6.40 D, both of which were statistically significant. The mean 1-month postoperative vault was 0.65 ± 0.13 mm and decreased to 0.613 ± 0.10 mm at 1 year postoperatively, with a change of 0.44 mm (P < .003). The preoperative/12-month and 1-month/12-month trabecular-iris angle (TIA), trabecular-iris space area 500 mm from the scleral spur (TISA500), and angle opening distance 500 mm from the scleral spur (AOD500) values were analyzed nasally, temporally, and inferiorly. All differences were statistically significant between preoperative/12-month analysis. The only differences between 1- and 12-month analysis were on TISA500 inferior (P < .002) and AOD500 nasal (0.031) values. ICL hyperopic toric implantation is a safe method and provides stable refractive outcomes in patients with high hyperopia (up to 10.00 D) and astigmatism (up to 6.00 D). [J Refract Surg. 2017;33(9):604-609.]. Copyright 2017, SLACK Incorporated.
Visual function of children with visual and other disabilities in Oman: A case series.
Gogri, Urmi; Khandekar, Rajiv; Al Harby, Salah
2016-12-01
We assessed the visual functioning of the children with special needs in Oman between 2009 and 2012. We present the methods of assessing different visual functions, outcomes, and interventions carried out to improve their functioning. Optometrists assessed visual functions of children of "Day care centres" in Oman. Experts further assessed them and provided low vision care. Ocular movements, refractive corrections, near, distance, contrast color, motion, field of vision, and cognitive visual function test results were noted. Feedback to caregivers was given to improve visual functioning of these children. We grouped 321 participants, (196 [61.1%] boys, age range of 3-18 years) into 61; Down syndrome (DS), 72 with intellectual disabilities (IDs), 67; hearing impaired and 121 with other conditions. Refractive error and lag of accommodation were 26 (42.6%) and 14 (22.6%) among children with DS. Contrast sensitivity was impaired in 8 (12.7%) among hearing impaired children. Defective distant and near vision was in 162 (70%) and 104 (42%) of our cohort. Children with ID were most difficult to assess. Children in a group of other disabilities had a higher proportion of impaired visual functioning. They were given low vision aids (telescopes [22], filters [7], and magnifiers [3]) in large numbers compared to those in other groups. Visual functioning of children with other disabilities show great variation and difficult to group. The care, therefore, should be at individual level. All visual functions cannot be assessed at one time.
NASA Technical Reports Server (NTRS)
Bautista, Abigail B.
1994-01-01
Twenty-four observers looked through a pair of 20 diopter wedge prisms and pointed to an image of a target which was displaced vertically from eye level by 6 cm at a distance of 30 cm. Observers pointed 40 times, using only their right hand, and received error-corrective feedback upon termination of each pointing response (terminal visual feedback). At three testing distances, 20, 30, and 40 cm, ten pre-exposure and ten post-exposure pointing responses were recorded for each hand as observers reached to a mirror-viewed target located at eye level. The difference between pre- and post-exposure pointing response (adaptive shift) was compared for both Exposed and Unexposed hands across all three testing distances. The data were assessed according to the results predicted by two alternative models for processing spatial-information: one using angular displacement information and another using linear displacement information. The angular model of spatial mapping best predicted the observer's pointing response for the Exposed hand. Although the angular adaptive shift did not change significantly as a function of distance (F(2,44) = 1.12, n.s.), the linear adaptive shift increased significantly over the three testing distances 02 44) = 4.90 p less than 0.01).
Qin, Bing; Li, Meiyan; Chen, Xun; Sekundo, Walter; Zhou, Xingtao
2018-05-01
To investigate early visual and refractive outcomes, corneal stability and optical quality after femtosecond laser small-incision lenticule extraction (SMILE) for treating myopia and myopic astigmatism over -10 D. Thirty eyes (30 patients) with myopia and myopic astigmatism of over -10 D were treated with VisuMax ® femtosecond laser (version 3.0; Carl Zeiss Meditec AG, Jena, Germany). Six months postoperative safety, efficacy and predictability were evaluated. Corneal Scheimpflug topography was measured preoperatively, 1 day, 3 months and 6 months postoperatively. Wavefront aberrations were measured preoperatively, 3 months and 6 months postoperatively. Six months postoperatively, LogMAR uncorrected and corrected distance visual acuity (CDVA) were -0.013 ± 0.086 and -0.073 ± 0.069, respectively. 73% (97%) of eyes were within 0.5 (1) D of target refraction. No eyes lost CDVA, 43% (13 eyes) gained one line and 7% (two eyes) gained two lines. Mean corneal back curvature (KMB) and posterior central elevation (PCE) did not change significantly comparing preoperative and 6 months postoperative data (p = 0.91 and 0.77, respectively). Comparing 1 day with 6 months postoperative data, central corneal thickness (CCT), mean corneal front curvature (KMF), KMB and PCE did not change significantly (p = 0.27, 0.07, 0.52, 0.71, respectively). Total higher-order aberration (HOA), spherical aberration and coma increased significantly (p < 0.01) but trefoil remained stable (p = 0.49). Our results indicate that SMILE can correct myopia and myopic astigmatism of over -10 D predictably. No early ectasia was observed. Long-term changes in visual quality and corneal stability require further investigation. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Ruiz-Alcocer, Javier; Madrid-Costa, David; García-Lázaro, Santiago; Albarrán-Diego, César; Ferrer-Blasco, Teresa
2013-07-01
The aim of this study was to analyse the visual quality of the AcrySof IQ SN60WF(®) intraocular lens (IOL) when combined with different corneal profiles. Ten eyes of 10 participants with no prior history of refractive or cataract surgery were evaluated. An adaptive optics visual simulator was used to simulate the wavefront aberration pattern of an aspheric aberration-correcting IOL (AcrySof IQ SN60WF(®)). Normal corneas (group A), low and high myopic corneal ablations (groups B and C, respectively) and low and high hyperopic corneal ablations (groups D and E, respectively) were also simulated. Monocular distance visual acuities at 100, 50 and 10 per cent of contrast were measured. At 100, 50 and 10 per cent contrast, no differences were found between groups A and B (p > 0.06 for all contrasts). Group A obtained better values than groups C, D and E for all contrasts (p = 0.031, p = 0.038, p = 0.032 at 100, 50 and 10 per cent of contrast, respectively). At the same time, group B obtained better values than groups C, D and E (p = 0.041, p = 0.042, p = 0.036 at 100, 50 and 10 per cent of contrast, respectively). Within the five groups, the worst results were always obtained for group E (p = 0.017, p = 0.021 and p = 0.025 at 100, 50 and 10 per cent of contrast, respectively). The results suggest that the aspheric aberration-correcting IOL studied provides comparable results, when it is combined with normal corneas and with corneas with simulated low myopic ablations. When negative amounts of residual spherical aberration after cataract surgery are expected to be achieved, IOLs with more positive spherical aberration should be considered. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon
2016-01-01
Purpose To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. Materials and Methods The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00–4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. Results The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Conclusion Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes. PMID:27593877
Alió, Jorge L; Plaza-Puche, Ana B; Martinez, Lorena M; Torky, Magda; Brenner, Luis F
2013-01-01
To evaluate the visual outcomes after laser in situ keratomileusis (LASIK) surgery to correct primary compound myopic astigmatism with high cylinder performed using a fast-repetition-rate excimer laser platform with optimized aspheric profiles and cyclotorsion control. Vissum Corporation and Division of Ophthalmology, Universidad Miguel Hernández, Alicante, Spain. Retrospective consecutive observational nonrandomized noncomparative case series. Eyes with primary compound myopic astigmatism and a cylinder power over 3.00 diopters (D) had uneventful LASIK with femtosecond flap creation and fast-repetition-rate excimer laser ablation with aspheric profiles and cyclotorsion control. Visual, refractive, and aberrometric outcomes were evaluated at the 6-month follow-up. The astigmatic correction was evaluated using the Alpins method and Assort software. The study enrolled 37 eyes (29 patients; age range 19 to 55 years). The significant reduction in refractive sphere and cylinder 3 months and 6 months postoperatively (P<.01) was associated with improved uncorrected distance visual acuity (P<.01). Eighty-seven percent of eyes had a spherical equivalent within ±0.50 D; 7.5% of eyes were retreated. There was no significant induction of higher-order aberrations (HOAs). The targeted and surgically induced astigmatism magnitudes were 3.23 D and 2.96 D, respectively, and the correction index was 0.91. The safety and efficacy indices were 1.05 and 0.95, respectively. Laser in situ keratomileusis for primary compound myopic astigmatism with high cylinder (>3.00 D) performed using a fast-repetition-rate excimer laser with optimized aspheric profiles and cyclotorsion control was safe, effective, and predictable and did not cause significant induction of HOAs. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Femtosecond laser correction of presbyopia (INTRACOR) in emmetropes using a modified pattern.
Thomas, Bettina C; Fitting, Anna; Auffarth, Gerd U; Holzer, Mike P
2012-12-01
To evaluate functional results and corneal changes after femtosecond laser correction of presbyopia (INTRACOR, Technolas Perfect Vision GmbH) in emmetropes using a modified treatment pattern over a 12-month period. Twenty eyes from 20 emmetropic patients were treated with a modified intrastromal INTRACOR pattern consisting of 5 central rings and 8 radial cuts in a prospective, nonrandomized, uncontrolled, open, single-center, clinical study. Refraction, visual acuity, endothelial cell density, corneal pachymetry, total corneal power, and stray light were evaluated preoperatively and 1 (except endothelial cell density and stray light), 3, 6, and 12 months postoperatively. Patients filled out a subjective questionnaire at 12 months postoperatively. Comparison of preoperative versus 12-month postoperative median values revealed a significant improvement in uncorrected near visual acuity (UNVA) from 0.60 (20/80) to 0.10 logMAR (20/25) (P<.0001) and a significant decrease in corrected distance visual acuity (CDVA) from -0.10 (20/16) to 0.00 logMAR (20/20), which equals a median loss of one line (P=.0005). Fifteen percent of patients lost two lines of CDVA in the treated eye. Subjective spherical equivalent refraction remained unchanged at 0.00 diopters (D) (P=.194). After INTRACOR treatment, significant corneal steepening of 1.40 D and midperipheral flattening of 0.50 D occurred (both P<.0001). Corneal pachymetry at the thinnest point and endothelial cell density did not change significantly (P=.829 and P=.058, respectively). After 12 months, the modified INTRACOR pattern improved UNVA in emmetropic patients without inducing a myopic shift or significant changes in endothelial cell density or pachymetry. Copyright 2012, SLACK Incorporated.
Lee, Jeihoon; Lee, Hun; Kang, David Sung Yong; Choi, Jin Young; Kim, Eung Kweon; Kim, Tae Im
2016-11-01
To compare the effectiveness of toric foldable iris-fixated phakic intraocular lens (pIOL) implantation and non-toric foldable iris-fixated pIOL implantation with limbal relaxing incisions (LRIs) for correcting moderate-to-high astigmatism in myopic eyes. The medical records of 146 patients (195 eyes) with myopic astigmatism who underwent toric foldable iris-fixated pIOL implantation (toric group; 94 eyes) or non-toric foldable iris-fixated pIOL implantation with concurrent LRIs (LRI group; 101 eyes) were retrospectively reviewed. For subgroup analysis, the two groups were subdivided according to preoperative astigmatic severity [moderate, 2.00 to <3.00 diopters (D); high, 3.00-4.00 D]. Visual and astigmatic outcomes were compared 6 months postoperatively. The uncorrected distance visual acuity was at least 20/25 in 100% and 98% of the toric and LRI group eyes, respectively. The toric group had lower mean residual cylindrical error (-0.67±0.39 D vs. -1.14±0.56 D; p<0.001) and greater mean cylindrical error change (2.17±0.56 D vs. 1.63±0.72 D; p<0.001) than the LRI group, regardless of the preoperative astigmatic severity. The mean correction index (1.10±0.16 vs. 0.72±0.24; p<0.001) and success index (0.24±0.14 vs. 0.42±0.21; p<0.001) also differed significantly between the groups. Both surgical techniques considerably reduced astigmatism and had comparable visual outcomes. However, toric foldable iris-fixated pIOL implantation was more reliable for correcting moderate-to-high astigmatism in myopic eyes.
Qureshi, Muhammad A; Robbie, Scott J; Hengerer, Fritz H; Auffarth, Gerd U; Conrad-Hengerer, Ina; Artal, Pablo
2018-03-01
To determine safety and visual outcomes in eyes with age-related macular degeneration (AMD) implanted with a novel intraocular lens (IOL) that delivers an optimized retinal image to all macular areas within 10 degrees of retinal eccentricity. This was a consecutive case series of 244 eyes with dry/stable wet AMD and logMAR visual acuity ≥0.3 implanted with iolAMD Eyemax mono TM (London Eye Hospital Pharma), a single-piece, injectable, hydrophobic acrylic IOL sited in the capsular bag. Primary outcome was safety. Secondary outcomes were changes in corrected distance visual acuity (CDVA) and corrected near visual acuity (CNVA) (logMAR). Mean age at surgery was 80 years. Mean duration of follow-up was 3 months (range 1-16 months). No eyes had worsening of CDVA. Frequency of perioperative complications was equivalent to standard IOL implantation. Postoperative refractive outcomes were within ±1 D of the target refraction in 88% of cases. Mean preoperative CDVA improved from 1.06 to 0.71 postoperatively (mean of differences -0.35; 95% confidence interval [CI] -0.3886 to -0.3223; p<0.0001), equating to an approximate Early Treatment Diabetic Retinopathy Study gain of 18 letters. Mean preoperative CNVA (N-point; logMAR conversion) improved from 1.36 to 0.88 postoperatively (mean of differences -0.48; 95% CI -0.53 to -0.44; p<0.0001). This novel IOL appears safe in the short to medium term. Improvements in postoperative CDVA and CNVA exceed those observed with standard implants.
Corrections Regarding the Impedance of Distance Functions for Several g(d) Functions
ERIC Educational Resources Information Center
Beaman, Jay
1976-01-01
Five functions were introduced for modeling travel behavior in the Beaman article "Distance and the 'Reaction' to Distance as a Function of Distance" published in Vol. 6, No. 3 of "Journal of Leisure Research" with the graphs of the functions printed incorrectly. This is a corrected version. (MM)
NASA Astrophysics Data System (ADS)
Xie, Xian-Hua; Yu, Zu-Guo; Ma, Yuan-Lin; Han, Guo-Sheng; Anh, Vo
2017-09-01
There has been a growing interest in visualization of metagenomic data. The present study focuses on the visualization of metagenomic data using inter-nucleotide distances profile. We first convert the fragment sequences into inter-nucleotide distances profiles. Then we analyze these profiles by principal component analysis. Finally the principal components are used to obtain the 2-D scattered plot according to their source of species. We name our method as inter-nucleotide distances profiles (INP) method. Our method is evaluated on three benchmark data sets used in previous published papers. Our results demonstrate that the INP method is good, alternative and efficient for visualization of metagenomic data.
NASA Technical Reports Server (NTRS)
Hughes, David; Perez, Xavier
2007-01-01
This presentation evaluates the parameters that affect visual inspection of cleanliness. Factors tested include surface reflectance, surface roughness, size of the largest particle, exposure time, inspector and distance from sample surface. It is concluded that distance predictions were not great, particularly because the distance at which contamination is seen may depend on more variables than those tested. Most parameters estimates had confidence of 95% or better, except for exposure and reflectance. Additionally, the distance at which surface is visibly contaminated decreases with increasing reflectance, roughness, and exposure. The distance at which the surface is visually contaminated increased with the largest particle size. These variables were only slightly affected the observer.
Zhang, Jin-Song; Zhao, Jiang-Yue; Sun, Qi; Ma, Li-Wei
2011-01-01
AIM To evaluate the distance vision of Chinese patients with cataracts and corneal astigmatism after implantation of bilateral AcrySof toric intraocular lens (IOL) versus bilateral AcrySof spherical IOL. METHODS This study randomized 60 patients into equal groups to receive toric IOL or spherical IOL. IOL powers targeting emmetropia were selected for 93% of toric IOL patients and for 90% of spherical IOL patients. Assessments included monocular and binocular distance vision, with and without best correction. Patients also completed surveys about their distance vision. RESULTS Preoperatively, the two study groups were similar in age, in distance visual acuity, and in the magnitude of corneal astigmatism. At 6 months postoperative, binocular uncorrected distance vision was 0.06±0.14 logMAR in the AcrySof toric IOL group, significantly better than the 0.14±0.11 logMAR in the spherical IOL group (P<0.05). For eyes with emmetropia as a target, the equivalent of 20/20 uncorrected vision was more likely (P<0.001) in the toric IOL group (36% of eyes) than in the spherical IOL group (4% of eyes). No patients in the emmetropia/toric IOL group used distance glasses, as compared to 52% of patients in the emmetropia/spherical IOL group. All patients were satisfied or highly satisfied. Quality of distance vision was rated higher by toric IOL patients than by spherical IOL patients (P<0.05). CONCLUSION Bilateral AcrySof toric IOL is superior to bilateral spherical IOL in providing uncorrected distance vision to cataract patients with corneal astigmatism. PMID:22553636
Kato, Sayaka; Ito, Misae; Shimizu, Kimiya; Kamiya, Kazutaka
2017-05-18
To evaluate the etiology and the clinical outcomes of secondary surgical interventions for dissatisfied patients after pseudophakic monovision. Department of Ophthalmology, Kitasato University Hospital, Kanagawa, Japan. Retrospective case series. This study comprised 12 eyes in 12 patients (age 66.2 ± 5.6 years) who underwent photorefractive keratectomy (PRK) enhancement to improve their dissatisfaction after pseudophakic monovision. We quantitatively assessed the visual and refractive outcomes and the subjective satisfaction measured using a visual analog scale, that ranged from 0 (very dissatisfied) to 10 (very satisfied), before and 3 months after PRK enhancement. Six (50%) of the 12 patients were dissatisfied with their various distance visions because of a large amount of anisometropia (≥2.50 D). Two (16.7%) were dissatisfied with their distance vision after conventional monovision because of residual cylindrical errors (≥0.75 D) in the dominant eye. Three (25%) was an unknown origin. The remaining one of the 12 patients was dissatisfied due to the unadaptability to crossed monovision. Eleven (91.7%) eyes were within ±0.5 D of the targeted correction after PRK enhancement. The overall satisfaction score was significantly improved, from 3.7 ± 2.4 (range 0-7) preoperatively to 6.0 ± 2.4 (range 2-9) postoperatively (p = 0.02). No vision-threatening complications were seen throughout the observation period. PRK enhancement was effective with predictable refractive results and thus improved patient satisfaction for dissatisfied patients after pseudophakic monovision. These findings also suggest that the accurate correction of refractive errors plays a key role in successful pseudophakic monovision.
Small refractive errors--their correction and practical importance.
Skrbek, Matej; Petrová, Sylvie
2013-04-01
Small refractive errors present a group of specifc far-sighted refractive dispositions that are compensated by enhanced accommodative exertion and aren't exhibited by loss of the visual acuity. This paper should answer a few questions about their correction, flowing from theoretical presumptions and expectations of this dilemma. The main goal of this research was to (dis)confirm the hypothesis about convenience, efficiency and frequency of the correction that do not raise the visual acuity (or if the improvement isn't noticeable). The next goal was to examine the connection between this correction and other factors (age, size of the refractive error, etc.). The last aim was to describe the subjective personal rating of the correction of these small refractive errors, and to determine the minimal improvement of the visual acuity, that is attractive enough for the client to purchase the correction (glasses, contact lenses). It was confirmed, that there's an indispensable group of subjects with good visual acuity, where the correction is applicable, although it doesn't improve the visual acuity much. The main importance is to eliminate the asthenopia. The prime reason for acceptance of the correction is typically changing during the life, so as the accommodation is declining. Young people prefer the correction on the ground of the asthenopia, caused by small refractive error or latent strabismus; elderly people acquire the correction because of improvement of the visual acuity. Generally the correction was found useful in more than 30%, if the gain of the visual acuity was at least 0,3 of the decimal row.
Etchemendy, Pablo E; Spiousas, Ignacio; Calcagno, Esteban R; Abregú, Ezequiel; Eguia, Manuel C; Vergara, Ramiro O
2018-06-01
In this study we evaluated whether a method of direct location is an appropriate response method for measuring auditory distance perception of far-field sound sources. We designed an experimental set-up that allows participants to indicate the distance at which they perceive the sound source by moving a visual marker. We termed this method Cross-Modal Direct Location (CMDL) since the response procedure involves the visual modality while the stimulus is presented through the auditory modality. Three experiments were conducted with sound sources located from 1 to 6 m. The first one compared the perceived distances obtained using either the CMDL device or verbal report (VR), which is the response method more frequently used for reporting auditory distance in the far field, and found differences on response compression and bias. In Experiment 2, participants reported visual distance estimates to the visual marker that were found highly accurate. Then, we asked the same group of participants to report VR estimates of auditory distance and found that the spatial visual information, obtained from the previous task, did not influence their reports. Finally, Experiment 3 compared the same responses that Experiment 1 but interleaving the methods, showing a weak, but complex, mutual influence. However, the estimates obtained with each method remained statistically different. Our results show that the auditory distance psychophysical functions obtained with the CMDL method are less susceptible to previously reported underestimation for distances over 2 m.
Perception of Auditory-Visual Distance Relations by 5-Month-Old Infants.
ERIC Educational Resources Information Center
Pickens, Jeffrey
1994-01-01
Sixty-four infants viewed side-by-side videotapes of toy trains (in four visual conditions) and listened to sounds at increasing or decreasing amplitude designed to match one of the videos. Results suggested that five-month olds were sensitive to auditory-visual distance relations and that change in size was an important visual depth cue. (MDM)
Modeling the Perception of Audiovisual Distance: Bayesian Causal Inference and Other Models
2016-01-01
Studies of audiovisual perception of distance are rare. Here, visual and auditory cue interactions in distance are tested against several multisensory models, including a modified causal inference model. In this causal inference model predictions of estimate distributions are included. In our study, the audiovisual perception of distance was overall better explained by Bayesian causal inference than by other traditional models, such as sensory dominance and mandatory integration, and no interaction. Causal inference resolved with probability matching yielded the best fit to the data. Finally, we propose that sensory weights can also be estimated from causal inference. The analysis of the sensory weights allows us to obtain windows within which there is an interaction between the audiovisual stimuli. We find that the visual stimulus always contributes by more than 80% to the perception of visual distance. The visual stimulus also contributes by more than 50% to the perception of auditory distance, but only within a mobile window of interaction, which ranges from 1 to 4 m. PMID:27959919
The Perspective Structure of Visual Space
2015-01-01
Luneburg’s model has been the reference for experimental studies of visual space for almost seventy years. His claim for a curved visual space has been a source of inspiration for visual scientists as well as philosophers. The conclusion of many experimental studies has been that Luneburg’s model does not describe visual space in various tasks and conditions. Remarkably, no alternative model has been suggested. The current study explores perspective transformations of Euclidean space as a model for visual space. Computations show that the geometry of perspective spaces is considerably different from that of Euclidean space. Collinearity but not parallelism is preserved in perspective space and angles are not invariant under translation and rotation. Similar relationships have shown to be properties of visual space. Alley experiments performed early in the nineteenth century have been instrumental in hypothesizing curved visual spaces. Alleys were computed in perspective space and compared with reconstructed alleys of Blumenfeld. Parallel alleys were accurately described by perspective geometry. Accurate distance alleys were derived from parallel alleys by adjusting the interstimulus distances according to the size-distance invariance hypothesis. Agreement between computed and experimental alleys and accommodation of experimental results that rejected Luneburg’s model show that perspective space is an appropriate model for how we perceive orientations and angles. The model is also appropriate for perceived distance ratios between stimuli but fails to predict perceived distances. PMID:27648222
Loffing, Florian; Schorer, Jörg; Hagemann, Norbert; Baker, Joseph
2012-02-01
High ball speeds and close distances between competitors require athletes in interactive sports to correctly anticipate an opponent's intentions in order to render appropriate reactions. Although it is considered crucial for successful performance, such skill appears impaired when athletes are confronted with a left-handed opponent, possibly because of athletes' reduced perceptual familiarity with rarely encountered left-handed actions. To test this negative perceptual frequency effect hypothesis, we invited 18 skilled and 18 novice volleyball players to predict shot directions of left- and right-handed attacks in a video-based visual anticipation task. In accordance with our predictions, and with recent reports on laterality differences in visual perception, the outcome of left-handed actions was significantly less accurately predicted than the outcome of right-handed attacks. In addition, this left-right bias was most distinct when predictions had to be based on preimpact (i.e., before hand-ball contact) kinematic cues, and skilled players were generally more affected by the opponents' handedness than were novices. The study's findings corroborate the assumption that skilled visual perception is attuned to more frequently encountered actions.
Manual small incision extracapsular cataract surgery in Australia.
van Zyl, Lourens; Kahawita, Shyalle; Goggin, Michael
2014-11-01
Examination of the results and describing the technique of manual small incision extracapsular cataract extraction on patients with advanced cataracts in urban Australia. A descriptive case series. Thirty-eight patients at three public hospitals, one tertiary and two secondary ophthalmic units in urban Australia. Forty eyes with dense mature cataracts with hand movement vision or worse underwent a planned manual small incision extracapsular cataract extraction instead of traditional phaco-emulsification. Postoperative visual aquity, surgically induced astigmatism and complications. Seventy-eight per cent of patients had an uncorrected visual acuity of 6/12 or better on the first postoperative day. Eighty-three per cent of patients had a distance corrected visual acuity of 6/9 or better 3 months postoperatively. One case was complicated by a posterior capsule rupture. No cases of endophthalmitis were reported. The summated vector mean of the surgically induced astigmatism was 0.089D at 93°. Manual small incision extracapsular cataract extraction is an efficacious cataract surgery technique with good visual outcome and is a safe alternative to phaco-emulsification in suitable cases in a first-world setting. © 2014 Royal Australian and New Zealand College of Ophthalmologists.
Jing, Wu; Guanlu, Liang; Qianyin, Zheng; Shuyi, Li; Fengying, He; Jian, Liu; Wen, Xu
2017-07-01
A meta-analysis to compare iris-claw intraocular lens (IC-IOL) and scleral-fixated posterior chamber intraocular lens (SF-PCIOL) implantations in correcting aphakia without sufficient capsular support. Eligible studies were collected through PubMed, Web of Science, Embase, and the Cochrane library. The pooled relative risks (RR), pooled standardized mean difference (SMD), and their 95% confidence interval of the eligible studies were then calculated. Seven studies met our inclusion criteria, involving 232 and 158 eyes in IC-IOL and SF-PCIOL groups, respectively. The pooled SMD of the mean postoperative corrected distance visual acuity (CDVA) (logMAR) was -0.25. The pooled RR of the eyes achieving 20/40 or better postoperatively was 1.16. The pooled SMD of the surgical time was -2.97. The pooled RR of the surgical complications was 0.86. The pooled RR of IOL dislocation, retinal detachment (RD), and cystoid macular edema (CME) between the two groups were 0.22, 0.63, and 0.64. Implantation of IC-IOL has a more simple procedure and shorter learning curve than SF-PCIOL implantation in correcting aphakia without sufficient capsular support.
Garzón, Nuria; Poyales, Francisco; de Zárate, Begoña Ortíz; Ruiz-García, Jose Luis; Quiroga, Juan Antonio
2015-02-01
To evaluate rotational stability and its influence on postoperative visual acuity of different monofocal and multifocal toric intraocular lenses (IOLs). A prospective interventional study was designed. Ninety-one patients with a mean age of 71.65 ± 11.82 years were implanted with toric IOLs after phacoemulsification. Three monofocal toric IOLs (the Lentis LT [Oculentis, Berlin, Germany], enVista [Bausch & Lomb, Rochester, NY], and AcrySof IQ [Alcon Laboratories, Inc., Fort Worth, TX]) and one multifocal toric IOL (AcrySof IQ ReSTOR; Alcon Laboratories, Inc.) were implanted. Preoperative and postoperative images were taken to calculate the misalignment due to the marking method. To evaluate rotation in the different follow-up visits, another photograph was taken 1 hour and 1, 7 and 30 days postoperatively. Refraction, uncorrected distance visual acuity (UDVA), and corrected distance visual acuity were measured 30 days postoperatively. Postoperative UDVA was 0.1 logMAR or better in 64.6% of eyes implanted with monofocal IOLs and 46.4% of eyes implanted with multifocal IOLs. The enVista toric IOL showed the best UDVA compared to the other monofocal IOLs, with 81% of eyes with 0.1 logMAR or better. The mean misalignment in the total group studied was 0.07° ± 0.60°; 69.6% of monofocal IOLs and 67.9% of multifocal IOLs showed less than 5° of rotation. A correlation was found between postoperative UDVA and rotation in the monofocal and multifocal IOLs implanted (r = 0.439 [P < .011] and = 0.787 [P = .001], respectively). At 1 month postoperatively, UDVA was slightly more affected by IOL rotation in multifocal than monofocal toric IOLs. The marking method was also effective. Copyright 2015, SLACK Incorporated.
[Binocular status of dyslexics--are there differences to a healthy comparison group?].
Riebeling, P; Brunner, E; Grossjohann, R; Clemens, S
2009-10-01
Despite numerous studies dealing with the question of a possible relation of visual problems and dyslexia, which is negated by most ophthalmologists, some opticians still favour the treatment of dyslexia by correction of the "Winkelfehlsichtigkeit" following MCH. Our aim was by also including the Pola test to check the usefulness of this treatment. In a 2-year prospective study we examined the 4th grade elementary school students in our city who had dyslexia as an assured diagnosis (n = 21). The results were compared to those of an age-matched group without pathological findings regarding their reading and spelling ability (n = 21). Examinations included visual acuity, eye position by cover test, Maddox cylinder and Pola test for near distance, binocular vision (Bagolini and Worth test, Lang test I and II, Titmus test, amplitude of fusion), amplitude of accommodation, refraction in cycloplegia and organic status. A significant difference was found between the two groups regarding the amplitude of divergence in near (p = 0.009) and far distance (p = 0.019) which were both smaller for the dyslexia group, as well as the binocular near visual acuity (p = 0.04). Using the SAS procedure STEPDISC we discriminated the normal and dyslexia group by amplitude of divergence, near visual acuity and alternating near prism cover test with a sensitivity of 81 % and a specifity of 75 %. The results of the Pola test did not show any significant difference between the groups. No differences were found between the groups regarding the eye position. Therefore a treatment of dyslexia using prisms does not appear reasonable. However because of the group sizes the significance of the results is limited. Georg Thieme Verlag KG Stuttgart.New York.
Hardten, David R; Fahmy, Mona M; Vora, Gargi K; Berdahl, John P; Kim, Terry
2015-07-01
To describe the long-term results of fibrin adhesive use in the management of epithelial ingrowth after laser in situ keratomileusis (LASIK). Private practice, Minneapolis, Minnesota, and an academic medical center, Durham, North Carolina, USA. Retrospective case series. Patients with a history of LASIK had epithelial ingrowth removal with mechanical debridement and fibrin glue application. Visual outcomes and the presence or absence of epithelial ingrowth were evaluated again after 3 months and at the last follow-up. The main outcome measures were recurrence of epithelial ingrowth and visual acuity. Thirty-nine eyes of 38 patients were evaluated. After epithelial ingrowth removal and application of fibrin glue, 31 eyes (79.5%) had no recurrence of ingrowth at the final follow-up and 5 eyes (12.8%) had mild epithelial ingrowth not requiring removal. Three eyes (7.7%) had significant epithelial ingrowth at the 3-month follow-up that required subsequent removal and fibrin application. At the 3-month follow-up visit, 76.9% of eyes achieved 20/25 or better corrected distance visual acuity (CDVA) and 69.2% of eyes achieved 20/40 or better uncorrected distance visual acuity (UDVA). At the last follow-up visit (mean 26.6 ± 17.0 months [SD]), 84.6% of eyes had 20/25 or better CDVA and 74.4% of eyes had 20/40 or better UDVA. Fibrin adhesive in conjunction with manual epithelial removal prevented a clinically significant recurrence of epithelial ingrowth in the majority of eyes. Larger randomized studies are needed to compare the success of this technique with that of others. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Effect of visual distortion on postural balance in a full immersion stereoscopic environment
NASA Astrophysics Data System (ADS)
Faubert, Jocelyn; Allard, Remy
2004-05-01
This study attempted to determine the influence of non-linear visual movements on our capacity to maintain postural control. An 8x8x8 foot CAVE immersive virtual environment was used. Body sway recordings were obtained for both head and lower back (lumbar 2-3) positions. The subjects were presented with visual stimuli for periods of 62.5 seconds. Subjects were asked to stand still on one foot while viewing stimuli consisting of multiplied sine waves generating movement undulation of a textured surface (waves moving in checkerboard pattern). Three wave amplitudes were tested: 4 feet, 2 feet, and 1 foot. Two viewing conditions were also used; observers looking at 36 inches in front of their feet; observers looking at a distance near the horizon. The results were compiled using an instability index and the data showed a profound and consistent effect of visual disturbances on postural balance in particular for the x (side-to-side) movement. We have demonstrated that non-linear visual distortions similar to those generated by progressive ophthalmic lenses of the kind used for presbyopia corrections, can generate significant postural instability. This instability is particularly evident for the side-to-side body movement and is most evident for the near viewing condition.
Correction of low corneal astigmatism in cataract surgery.
Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele
2015-01-01
To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision.
Correction of low corneal astigmatism in cataract surgery
Leon, Pia; Pastore, Marco Rocco; Zanei, Andrea; Umari, Ingrid; Messai, Meriem; Negro, Corrado; Tognetto, Daniele
2015-01-01
AIM To evaluate and compare aspheric toric intraocular lens (IOL) implantation and aspheric monofocal IOL implantation with limbal relaxing incisions (LRI) to manage low corneal astigmatism (1.0-2.0 D) in cataract surgery. METHODS A prospective randomized comparative clinical study was performed. There were randomly recruited 102 eyes (102 patients) with cataracts associated with corneal astigmatism and divided into two groups. The first group received toric IOL implantation and the second one monofocal IOL implantation with peripheral corneal relaxing incisions. Outcomes considered were: visual acuity, postoperative residual astigmatism, endothelial cell count, the need for spectacles, and patient satisfaction. To determine the postoperative toric axis, all patients who underwent the toric IOL implantation were further evaluated using an OPD Scan III (Nidek Co, Japan). Follow-up lasted 6mo. RESULTS The mean uncorrected distance visual acuity (UCVA) and the best corrected visual acuity (BCVA) demonstrated statistically significant improvement after surgery in both groups. At the end of the follow-up the UCVA was statistically better in the patients with toric IOL implants compared to those patients who underwent implantation of monofocal IOL plus LRI. The mean residual refractive astigmatism was of 0.4 D for the toric IOL group and 1.1 D for the LRI group (P<0.01). No difference was observed in the postoperative endothelial cell count between the two groups. CONCLUSION The two surgical procedures demonstrated a significant decrease in refractive astigmatism. Toric IOL implantation was more effective and predictable compared to the limbal relaxing incision. PMID:26309869
Zhu, Mengjun; Tong, Xiaowei; Zhao, Rong; He, Xiangui; Zhao, Huijuan; Zhu, Jianfeng
2017-11-28
To investigate the prevalence and risk factors of undercorrected refractive error (URE) among people with diabetes in the Baoshan District of Shanghai, where data for undercorrected refractive error are limited. The study was a population-based survey of 649 persons (aged 60 years or older) with diabetes in Baoshan, Shanghai in 2009. One copy of the questionnaire was completed for each subject. Examinations included a standardized refraction and measurement of presenting and best-corrected visual acuity (BCVA), tonometry, slit lamp biomicroscopy, and fundus photography. The calculated age-standardized prevalence rate of URE was 16.63% (95% confidence interval [CI] 13.76-19.49). For visual impairment subjects (presenting vision worse than 20/40 in the better eye), the prevalence of URE was up to 61.11%, and 75.93% of subjects could achieve visual acuity improvement by at least one line using appropriate spectacles. Under multiple logistic regression analysis, older age, female gender, non-farmer, increasing degree of myopia, lens opacities status, diabetic retinopathy (DR), body mass index (BMI) index lower than normal, and poor glycaemic control were associated with higher URE levels. Wearing distance eyeglasses was a protective factor for URE. The undercorrected refractive error in diabetic adults was high in Shanghai. Health education and regular refractive assessment are needed for diabetic adults. Persons with diabetes should be more aware that poor vision is often correctable, especially for those with risk factors.
Visual Predictive Check in Models with Time-Varying Input Function.
Largajolli, Anna; Bertoldo, Alessandra; Campioni, Marco; Cobelli, Claudio
2015-11-01
The nonlinear mixed effects models are commonly used modeling techniques in the pharmaceutical research as they enable the characterization of the individual profiles together with the population to which the individuals belong. To ensure a correct use of them is fundamental to provide powerful diagnostic tools that are able to evaluate the predictive performance of the models. The visual predictive check (VPC) is a commonly used tool that helps the user to check by visual inspection if the model is able to reproduce the variability and the main trend of the observed data. However, the simulation from the model is not always trivial, for example, when using models with time-varying input function (IF). In this class of models, there is a potential mismatch between each set of simulated parameters and the associated individual IF which can cause an incorrect profile simulation. We introduce a refinement of the VPC by taking in consideration a correlation term (the Mahalanobis or normalized Euclidean distance) that helps the association of the correct IF with the individual set of simulated parameters. We investigate and compare its performance with the standard VPC in models of the glucose and insulin system applied on real and simulated data and in a simulated pharmacokinetic/pharmacodynamic (PK/PD) example. The newly proposed VPC performance appears to be better with respect to the standard VPC especially for the models with big variability in the IF where the probability of simulating incorrect profiles is higher.
NASA Astrophysics Data System (ADS)
Samigulina, Galina A.; Shayakhmetova, Assem S.
2016-11-01
Research objective is the creation of intellectual innovative technology and information Smart-system of distance learning for visually impaired people. The organization of the available environment for receiving quality education for visually impaired people, their social adaptation in society are important and topical issues of modern education.The proposed Smart-system of distance learning for visually impaired people can significantly improve the efficiency and quality of education of this category of people. The scientific novelty of proposed Smart-system is using intelligent and statistical methods of processing multi-dimensional data, and taking into account psycho-physiological characteristics of perception and awareness learning information by visually impaired people.
Causes of visual impairment in children with low vision.
Shah, Mufarriq; Khan, Mirzaman; Khan, Muhammad Tariq; Khan, Mohammad Younas; Saeed, Nasir
2011-02-01
To determine the main causes of visual impairment in children with low vision. To assess the need of spectacles and low vision devices (LVDs) in children and to evaluate visual outcome after using their LVDs for far and near distance. Observational study. Khyber Institute of Ophthalmic Medical Sciences, Peshawar, Pakistan, from June 2006 to December 2007. The clinical record of 270 children with low vision age 4-16 years attending the Low Vision Clinic were included. All those children, aged 4-16 years, who had corrected visual acuity (VA) less than 6/18 in the better eye after medical or surgical treatment, were included in the study. WHO low vision criteria were used to classify into visually impaired, severe visually impaired and blind. Results were described as percentage frequencies. One hundred and eighty nine (70%) were males and 81 (30%) were females. The male to female ratio was 2.3:1. The main causes of visual impairment included nystagmus (15%), Stargardt's disease (14%), maculopathies (13%), myopic macular degeneration (11%) and oculocutaneous albinism (7%). The percentages of visually impaired, severe visually impaired and blind were 33.8%, 27.2% and 39.0% respectively. Spectacles were prescribed to 146 patients and telescopes were prescribed to 75 patients. Spectacles and telescope both were prescribed to 179 patients while Ocutech telescope was prescribed to 4 patients. Retinal diseases nystagmus and macular conditions were mainly responsible for low vision in children. Visually impaired children especially with hereditary/congenital ocular anomalies benefit from refraction and low vision services which facilitate vision enhancement and inclusive education.
Yotsukura, Erisa; Torii, Hidemasa; Saiki, Megumi; Negishi, Kazuno; Tsubota, Kazuo
2016-03-01
To evaluate the effect of neodymium:YAG (Nd:YAG) laser capsulotomy on the visual function in patients with posterior capsule opacification (PCO) and good visual acuity. Keio University Hospital, Tokyo, Japan. Observational case series. Eyes were evaluated that had previous cataract surgery with a clinical diagnosis of PCO requiring Nd:YAG laser capsulotomy regardless of a good corrected distance visual acuity (CDVA) (at least 20/20). The CDVA, 10% low contrast visual acuity (LCVA), wavefront aberrations from the 3rd to 6th order, and retinal straylight were measured before and after Nd:YAG laser capsulotomy. The study included 16 eyes of 16 patients (10 men, 6 women; mean age 69.5 years ± 9.3 [SD]). The mean CDVA, LCVA, and straylight after Nd:YAG laser capsulotomy improved significantly (P < .05). The root mean square (RMS) of the 3rd Zernike coefficients (S3) and the RMS of the total higher-order aberrations (HOAs) from the 3rd to 6th order decreased significantly after capsulotomy (P < .05). The straylight correlated significantly with the total HOAs (r = 0.727, P = .002) and S3 (r = 0.748, P = .001) before capsulotomy. Subjective symptoms resolved after capsulotomy in all cases. Neodymium:YAG laser capsulotomy enabled a significant improvement in visual function even in patients with PCO with good visual acuity. Straylight measurements might be useful to determine the indications for Nd:YAG laser capsulotomy when patients report visual disturbances without decreased visual acuity. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Method of mobile robot indoor navigation by artificial landmarks with use of computer vision
NASA Astrophysics Data System (ADS)
Glibin, E. S.; Shevtsov, A. A.; Enik, O. A.
2018-05-01
The article describes an algorithm of the mobile robot indoor navigation based on the use of visual odometry. The results of the experiment identifying calculation errors in the distance traveled on a slip are presented. It is shown that the use of computer vision allows one to correct erroneous coordinates of the robot with the help of artificial landmarks. The control system utilizing the proposed method has been realized on the basis of Arduino Mego 2560 controller and a single-board computer Raspberry Pi 3. The results of the experiment on the mobile robot navigation with the use of this control system are presented.
Refractive errors in presbyopic patients in Kano, Nigeria.
Lawan, Abdu; Okpo, Eme; Philips, Ebisike
2014-01-01
The study is a retrospective review of the pattern of refractive errors in presbyopic patients seen in the eye clinic from January to December, 2009. The clinic refraction register was used to retrieve the case folders of all patients refracted during the review period. Information extracted includes patient's age, sex, and types of refractive error. Unaided and pin hole visual acuity was done with Snellen's or "E" Charts and near vision with Jaeger's chart in English or Hausa. All patients had basic eye examination and streak retinoscopy at two third meter working distance. The final subjective refractive correction given to the patients was used to categorize the type of refractive error. There were 5893 patients, 1584 had refractive error and 644 were presbyopic. There were 289 males and 355 females (M:F= 1:1.2). Presbyopia accounted for 10.9% of clinic attendance and 40% of patients with refractive error. Presbyopia was seen in 17%, the remaining 83% required distance correction; astigmatism was seen in 41%, hypermetropia 29%, myopia 9% and aphakia 4%. Refractive error was commoner in females than males and the relationship was statistically significant (P-value = 0.017; P < 0.05 considered significant). Presbyopia is common and most of the patients had other refractive errors. Full refraction is advised for all patients.
Distance Education for People with Visual Impairments
ERIC Educational Resources Information Center
Liakou, Maria; Manousou, Evaggelia
2015-01-01
This paper studies the standards of higher Distance Education, focusing on the Hellenic Open University, for people who have visual impairments, so that it becomes fully accessible and thus helps reduce social exclusion. Specifically, it aims to study the operational context of Distance Education, the possibilities that modern technology provides…
Application of distance correction to ChemCam laser-induced breakdown spectroscopy measurements
Mezzacappa, A.; Melikechi, N.; Cousin, A.; ...
2016-04-04
Laser-induced breakdown spectroscopy (LIBS) provides chemical information from atomic, ionic, and molecular emissions from which geochemical composition can be deciphered. Analysis of LIBS spectra in cases where targets are observed at different distances, as is the case for the ChemCam instrument on the Mars rover Curiosity, which performs analyses at distances between 2 and 7.4 m is not a simple task. Previously, we showed that spectral distance correction based on a proxy spectroscopic standard created from first-shot dust observations on Mars targets ameliorates the distance bias in multivariate-based elemental-composition predictions of laboratory data. In this work, we correct an expandedmore » set of neutral and ionic spectral emissions for distance bias in the ChemCam data set. By using and testing different selection criteria to generate multiple proxy standards, we find a correction that minimizes the difference in spectral intensity measured at two different distances and increases spectral reproducibility. When the quantitative performance of distance correction is assessed, there is improvement for SiO 2, Al 2O 3, CaO, FeOT, Na 2O, K 2O, that is, for most of the major rock forming elements, and for the total major-element weight percent predicted. But, for MgO the method does not provide improvements while for TiO 2, it yields inconsistent results. Additionally, we observed that many emission lines do not behave consistently with distance, evidenced from laboratory analogue measurements and ChemCam data. This limits the effectiveness of the method.« less
Botulinum Toxin as an Alternative to Treat the Spasm of the Near Reflex.
Laria, Carlos; Merino-Suárez, María L; Piñero, David P; Gómez-Hurtado, Arantxa; Pérez-Cambrodí, Rafael J
2015-01-01
We describe the case of an eight-year-old girl with complaints of headaches and blurred vision (uncorrected visual acuity: 0.1 decimal) that showed on examination miotic pupils, pseudomyopia, no ocular motility restrictions, and no associated neurological disease. After initial treatment with cyclopentolate for two months, pseudomyopia persisted with an intermittent and variable esotropia. Spectacles of +1 both eyes and atropine 1% one drop daily were then prescribed. The situation improved and remained stable for several weeks, with pseudomyopia and esotropia reappearing later. Finally, botulinum toxin (2.5 iu Botox) was injected in the medial rectus muscle on two occasions and a visual therapy program based on the stimulation of fusional divergence, diplopia, and stereopsis consciousness was recommended. This prescription was combined with the use of atropine during the first few weeks. Orthotropia and corrected distance visual acuity of 1.0 were found three months after treatment. The evolution and clinical results of this case report suggest that botulinum toxin in combination with other therapeutic alternatives may be useful in the treatment of spasm of the near reflex.
McTavish, Emily Jane; Steel, Mike; Holder, Mark T
2015-12-01
Statistically consistent estimation of phylogenetic trees or gene trees is possible if pairwise sequence dissimilarities can be converted to a set of distances that are proportional to the true evolutionary distances. Susko et al. (2004) reported some strikingly broad results about the forms of inconsistency in tree estimation that can arise if corrected distances are not proportional to the true distances. They showed that if the corrected distance is a concave function of the true distance, then inconsistency due to long branch attraction will occur. If these functions are convex, then two "long branch repulsion" trees will be preferred over the true tree - though these two incorrect trees are expected to be tied as the preferred true. Here we extend their results, and demonstrate the existence of a tree shape (which we refer to as a "twisted Farris-zone" tree) for which a single incorrect tree topology will be guaranteed to be preferred if the corrected distance function is convex. We also report that the standard practice of treating gaps in sequence alignments as missing data is sufficient to produce non-linear corrected distance functions if the substitution process is not independent of the insertion/deletion process. Taken together, these results imply inconsistent tree inference under mild conditions. For example, if some positions in a sequence are constrained to be free of substitutions and insertion/deletion events while the remaining sites evolve with independent substitutions and insertion/deletion events, then the distances obtained by treating gaps as missing data can support an incorrect tree topology even given an unlimited amount of data. Copyright © 2015 Elsevier Inc. All rights reserved.
Li, Meiyan; Zhao, Jing; Miao, Huamao; Shen, Yang; Sun, Ling; Tian, Mi; Wadium, Elizabeth; Zhou, Xingtao
2014-05-20
To measure decentration following femtosecond laser small incision lenticule extraction (SMILE) for the correction of myopia and myopic astigmatism in the early learning curve, and to investigate its impact on visual quality. A total of 55 consecutive patients (100 eyes) who underwent the SMILE procedure were included. Decentration was measured using a Scheimpflug camera 6 months after surgery. Uncorrected and corrected distance visual acuity (UDVA, CDVA), manifest refraction, and wavefront errors were also measured. Associations between decentration and the preoperative spherical equivalent were analyzed, as well as the associations between decentration and wavefront aberrations. Regarding efficacy and safety, 40 eyes (40%) had an unchanged CDVA; 32 eyes (32%) gained one line; and 11 eyes (11%) gained two lines. Fifteen eyes (15%) lost one line of CDVA, and two eyes (2%) lost two lines. Ninety-nine of the treated eyes (99%) had a postoperative UDVA better than 1.0, and 100 eyes (100%) had a UDVA better than 0.8. The mean decentered displacement was 0.17 ± 0.09 mm. The decentered displacement of all treated eyes (100%) was within 0.50 mm; 70 eyes (70%) were within 0.20 mm; and 90 eyes (90%) were within 0.30 mm. The vertical coma showed the greatest increase in magnitude. The magnitude of horizontal decentration was found to be associated with an induced horizontal coma. This study suggests that, although mild decentration occurred in the early learning curve, good visual outcomes were achieved after the SMILE surgery. Special efforts to minimize induced vertical coma are necessary. Copyright 2014 The Association for Research in Vision and Ophthalmology, Inc.
Vision related quality of life in patients with type 2 diabetes in the EUROCONDOR trial.
Trento, Marina; Durando, Olga; Lavecchia, Sonia; Charrier, Lorena; Cavallo, Franco; Costa, Miguel Angelo; Hernández, Cristina; Simó, Rafael; Porta, Massimo
2017-07-01
To evaluate vision related quality of life in the patients enrolled in The European Consortium for the Early Treatment of Diabetic Retinopathy, a clinical trial on prevention of diabetic retinopathy. Four-hundred-forty-nine patients, 153 women, with type 2 Diabetes and no or mild diabetic retinopathy were enrolled in a 2-year multicenter randomized controlled trial. The 25-item National Eye Institute Visual Functioning Questionnaire was used to explore 12 subscales of vision related quality of life. The patients were 62.8 ± 6.7 years old and had 11.1 ± 5.6 years known disease duration. Diabetic retinopathy was absent in 193 (43.0 %) and mild in 256 (57.0 %). Patients without diabetic retinopathy were older, had shorter diabetes duration and used less insulin and glucose-lowering agents but did not differ by gender, best corrected visual acuity or any subscale, except vision specific mental health and vision specific role difficulties. Patients with reduced retinal thickness at the ganglion cell layer (n = 36) did not differ for diabetic retinopathy but were older, had lower best corrected visual acuity and worse scores for ocular pain, color vision and peripheral vision. On multivariable analysis, worse scores for general vision remained associated with reduced retinal thickness, diabetes duration and best corrected visual acuity, and scores for visual specific mental health with diabetic retinopathy and lower best corrected visual acuity. Visual specific role difficulties were only associated with reduced best corrected visual acuity. Scores for driving decreased among females, with worsening of Hemoglobin A1c and best corrected visual acuity. Color vision depended only on reduced retinal thickness, and peripheral vision on both reduced thickness and best corrected visual acuity. The National Eye Institute Visual Functioning Questionnaire could detect subtle changes in patients' perception of visual function, despite absent/minimal diabetic retinopathy.
The extent of visual space inferred from perspective angles
Erkelens, Casper J.
2015-01-01
Retinal images are perspective projections of the visual environment. Perspective projections do not explain why we perceive perspective in 3-D space. Analysis of underlying spatial transformations shows that visual space is a perspective transformation of physical space if parallel lines in physical space vanish at finite distance in visual space. Perspective angles, i.e., the angle perceived between parallel lines in physical space, were estimated for rails of a straight railway track. Perspective angles were also estimated from pictures taken from the same point of view. Perspective angles between rails ranged from 27% to 83% of their angular size in the retinal image. Perspective angles prescribe the distance of vanishing points of visual space. All computed distances were shorter than 6 m. The shallow depth of a hypothetical space inferred from perspective angles does not match the depth of visual space, as it is perceived. Incongruity between the perceived shape of a railway line on the one hand and the experienced ratio between width and length of the line on the other hand is huge, but apparently so unobtrusive that it has remained unnoticed. The incompatibility between perspective angles and perceived distances casts doubt on evidence for a curved visual space that has been presented in the literature and was obtained from combining judgments of distances and angles with physical positions. PMID:26034567
Ferraro, M; Foster, D H
1991-01-01
Under certain experimental conditions, visual discrimination performance in multielement images is closely related to visual identification performance: elements of the image are distinguished only insofar as they appear to have distinct, discrete, internal characterizations. This report is concerned with the detailed relationship between such internal characterizations and observable discrimination performance. Two types of general processes that might underline discrimination are considered. The first is based on computing all possible internal image characterizations that could allow a correct decision, each characterization weighted by the probability of its occurrence and of a correct decision being made. The second process is based on computing the difference between the probabilities associated with the internal characterizations of the individual image elements, the difference quantified naturally with an l(p) norm. The relationship between the two processes was investigated analytically and by Monte Carlo simulations over a plausible range of numbers n of the internal characterizations of each of the m elements in the image. The predictions of the two processes were found to be closely similar. The relationship was precisely one-to-one, however, only for n = 2, m = 3, 4, 6, and for n greater than 2, m = 3, 4, p = 2. For all other cases tested, a one-to-one relationship was shown to be impossible.
Rim, Tyler H T; Nam, Jae S; Choi, Moonjung; Lee, Sung C; Lee, Christopher S
2014-06-01
To describe the age, gender specific prevalence and risk factors of visual impairment and blindness in Korea. From 2008 to 2010, a total 14 924 randomly selected national representative participants of the Korea National Health and Nutrition Examination Survey underwent additional ophthalmologic examinations by the Korean Ophthalmologic Society. Best Corrected Distance Visual Acuity was measured using an international standard vision chart based on Snellen scale (Jin's vision chart). Independent risk factors for visual impairment were investigated using multivariate logistic regression analysis. The overall prevalence of visual impairment (≤20/40) of adults 40 years and older was 4.1% (95% CI, 3.6-4.6) based on the better seeing eye. The overall prevalence of blindness (≤20/200) for adults 40 years and older was 0.2% (95% CI, 0.1-0.3). Risk indicators of visual impairment were increasing age, low education status, living in rural area, being unemployed, being without spouse and the absence of private health insurance. The visually impaired were more likely to have eye diseases compared with the normal subjects, and they were less likely to utilize eye care. The prevalence of visual impairment was demonstrated to be higher while that of blindness was similar to previous population studies in Asia or U.S. Sociodemographic disparities are present in the prevalence of visual impairment and more targeted efforts are needed to promote vision screening in high risk groups. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Visual outcomes after Epi-LASIK and PRK for low and moderate myopia.
Sia, Rose K; Coe, Charles D; Edwards, Jayson D; Ryan, Denise S; Bower, Kraig S
2012-01-01
To evaluate visual outcomes following epi-LASIK compared to photorefractive keratectomy (PRK). Of a total 294 patients aged ≥21 years, 145 (290 eyes) underwent epi-LASIK and 149 (298 eyes) underwent PRK for low to moderate myopia or myopic astigmatism. Epi-LASIK was performed with the Amadeus II epikeratome (Abbott Medical Optics) and PRK with the Amoils rotary epithelial brush (Innovative Excimer Solutions). All ablations were performed using the same excimer laser system. Outcome measures included intraoperative complications, corneal reepithelialization, postoperative pain, uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), corrected distance visual acuity (CDVA), corneal haze, and quality of vision. Mean preoperative MRSE was -2.97±1.19 diopters (D) for epi-LASIK versus -2.95±1.06 D for PRK. Complete reepithelialization was achieved by postoperative day 4 in 46.9% of epi-LASIK eyes versus 92.4% of PRK eyes, with superior UDVA at postoperative day 1 in the PRK group (P=.002). Using Fisher exact test, a significantly higher percentage of epi-LASIK eyes compared to PRK eyes achieved 20/15 or better at 1 month (25.8% vs 17.8%, P=.031), 3 months (62.3% vs 49.3%, P=.004), 6 months (77.1% vs 57.9%, P<.001), and 12 months (75.9% vs 61.9%, P=.002). A change in MRSE >0.50 D occurred in 8.4% of epi-LASIK eyes within the 3- and 12-month interval versus 17.7% of PRK eyes (P=.04). No differences were noted between the two procedures in CDVA or clinically significant haze. Epi-LASIK showed superior refractive efficacy and stability but required more time for wound healing, resulting in inferior early visual outcomes and a tendency to overcorrect higher refractive errors compared to PRK. Both treatments were safe and comparable in terms of pain and haze formation. Copyright 2012, SLACK Incorporated.
76 FR 64169 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-17
... detachment in his left eye due to a traumatic injury that occurred in 1982. The best corrected visual acuity... traumatic injury sustained in 2000. The best corrected visual acuity in his right eye is 20/30. Following an... to an injury sustained in 1976. The best corrected visual acuity in his left eye is 20/15. Following...
Kamiya, Kazutaka; Shimizu, Kimiya; Miyake, Toshiyuki
2016-07-01
To assess the changes in astigmatism and higher-order aberrations (HOAs) after toric intraocular lens (IOL) implantation for mild non-progressive keratoconus with cataract. We prospectively examined 19 eyes of 19 consecutive keratoconic patients (mean age ± standard deviation, 63.1 ± 9.1 years) who underwent phacoemulsification with toric IOL implantation. We determined uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive astigmatism, corneal astigmatism, corneal HOAs and astigmatic axis rotation both preoperatively and 3 months postoperatively. Logarithm of the minimal angle of resolution (logMAR) UDVA was significantly improved from 1.14 ± 0.50 preoperatively to 0.46 ± 0.33 postoperatively (Wilcoxon signed-rank test, p < 0.001). LogMAR CDVA was also significantly improved from 0.27 ± 0.45 preoperatively to -0.01 ± 0.09 postoperatively (p < 0.001). In 5 of 6 eyes in which the target refraction was emmetropia, postoperative UDVA was better than 20/32. The achieved spherical equivalent correction was within ±0.5 diopters (D) of the targeted correction in 13 (68 %) eyes and 1.0 in 18 (95 %) eyes. The refractive astigmatism was significantly decreased from -1.92 ± 1.73 D preoperatively to -0.70 ± 0.60 D postoperatively (p = 0.006). The corneal astigmatism changed from 2.89 ± 1.30 D preoperatively to 2.98 ± 1.09 D postoperatively (p = 0.492), which was not statistically significant. The corneal HOAs for a 4-mm pupil was changed from 0.47 ± 0.23 µm preoperatively to 0.52 ± 0.26 µm postoperatively (p = 0.211), which was not statistically significant. According to our experience, toric IOL implantation for mild keratoconic patients having rigid gas-permeable lens intolerance appears to be effective for reducing refractive astigmatism without a significant induction of corneal HOAs.
Lin, David T C; Holland, Simon P; Verma, Shwetabh; Hogden, John; Arba-Mosquera, Samuel
2017-12-01
To evaluate the postoperative asphericity in low, moderate, and high myopic eyes after combined transepithelial photorefractive keratectomy and SmartSurf ACE treatment (SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany). In this retrospective case series, the outcomes of myopic SmartSurf ACE were evaluated at 3 months postoperatively in 106 eyes and divided into low (less than -4.125 diopters [D]), moderate (-4.125 to -6.25 D), and high (more than -6.25 D) myopia groups. In all cases, standard examinations and preoperative and postoperative corneal topography (SCHWIND Sirius) were performed. The analysis comprised evaluating the change in asphericity versus planned correction, comparing expected and achieved postoperative asphericity for all eyes, and comparison of the three groups in terms of the preoperative and postoperatively expected and achieved asphericity. RESULTS At 3 months postoperatively, the low myopia group (n = 33) improved average negative asphericity (Q = -0.04 ± 0.17 preoperative vs -0.19 ± 0.20 postoperative, P < .05). The moderate myopia group (n = 35) maintained or slightly improved average negative asphericity (Q = -0.07 ± 0.14 preoperative vs -0.05 ± 0.24 postoperative, P = .35). For the high myopia group (n = 38), the eyes became more oblate compared to the preoperative status (Q = -0.09 ± 0.15 preoperative vs 0.62 ± 0.70 postoperative, P < .05). In terms of asphericity, the difference between the three groups was not statistically significant preoperatively (P > .10), but showed significant differences postoperatively (P < .007). The cohort's average preoperative corrected distance visual acuity was 0.01 ± 0.04 logMAR (range: 0.0 to 0.18 logMAR) and uncorrected distance visual acuity was 0.03 ± 0.08 logMAR (range: -0.12 to 0.40 logMAR) 3 months postoperatively. SmartSurf ACE maintained or slightly improved preoperative corneal asphericity for low to moderate myopic corrections (up to -6.00 D). This may provide advantages in the quality of vision and the onset of presbyopic symptoms after laser refractive surgery in myopic patients. [J Refract Surg. 2017;33(12):820-826.]. Copyright 2017, SLACK Incorporated.
Berdeaux, Gilles; Viala, Muriel; Roborel de Climens, Aude; Arnould, Benoit
2008-01-01
Background Restoration of functional distance and near vision independently of additional correction remains a goal for cataract surgery. ReSTOR®, a new multi-focal intraocular lens (IOL) addresses this issue with an improvement in both distance and near vision, often without need for glasses. This analysis attempted to discuss the patient-reported benefit of ReSTOR® using a full but organised representation of data. Methods Two non-randomised, open-label clinical trials conducted in Europe and the United-States were conducted to compare the efficacy of ReSTOR® to AcrySof® mono-focal IOLs. A total of 710 patients in need of bilateral cataract extraction were included in the pooled study. The TyPE, a patient questionnaire, was fully completed by 672 of them before and after each eye surgery. The TyPE, composed of 67 items measuring overall visual functioning in both conditions (with and without wearing glasses), evaluates limitations, troubles and satisfaction in distance and near vision. A principal component analysis (PCA) of the TyPE questionnaire was performed on pooled data from baseline and post-surgery observations in order to fully represent the change in the TyPE data over time. ReSTOR® and mono-focal groups were used as illustrative variables. The coordinates of the first 2 factors were compared between visits and between IOLs (ReSTOR® vs. mono-focal), using paired t-tests and t-tests, respectively. Results The first factor of the PCA explained 55% of the variance and represented 'visual functioning and patient satisfaction'. The second factor explained 6% of the variance and was interpreted as 'independence from glasses'. An overall difference in factorial coordinates in both factors was seen between baseline and the first eye surgery, and between the first and the second eye surgery. No difference between ReSTOR® and mono-focal IOL groups was observed at baseline. After surgery, ReSTOR® treated-patients had higher coordinates on both "visual functioning and satisfaction" and "independence from glasses" factors. Findings observed on the factorial plan were supported by statistical comparisons of factorial coordinates. Conclusion Both mono-focal and ReSTOR®-implanted patients improved their visual functioning after bilateral cataract surgery. Moreover, ReSTOR® patients reported an additional benefit in independence from glasses as well as in visual functioning and patient satisfaction. PMID:18218068
Berdeaux, Gilles; Viala, Muriel; Roborel de Climens, Aude; Arnould, Benoit
2008-01-24
Restoration of functional distance and near vision independently of additional correction remains a goal for cataract surgery. ReSTOR, a new multi-focal intraocular lens (IOL) addresses this issue with an improvement in both distance and near vision, often without need for glasses. This analysis attempted to discuss the patient-reported benefit of ReSTOR using a full but organised representation of data. Two non-randomised, open-label clinical trials conducted in Europe and the United-States were conducted to compare the efficacy of ReSTOR to AcrySof mono-focal IOLs. A total of 710 patients in need of bilateral cataract extraction were included in the pooled study. The TyPE, a patient questionnaire, was fully completed by 672 of them before and after each eye surgery. The TyPE, composed of 67 items measuring overall visual functioning in both conditions (with and without wearing glasses), evaluates limitations, troubles and satisfaction in distance and near vision. A principal component analysis (PCA) of the TyPE questionnaire was performed on pooled data from baseline and post-surgery observations in order to fully represent the change in the TyPE data over time. ReSTOR and mono-focal groups were used as illustrative variables. The coordinates of the first 2 factors were compared between visits and between IOLs (ReSTOR vs. mono-focal), using paired t-tests and t-tests, respectively. The first factor of the PCA explained 55% of the variance and represented 'visual functioning and patient satisfaction'. The second factor explained 6% of the variance and was interpreted as 'independence from glasses'. An overall difference in factorial coordinates in both factors was seen between baseline and the first eye surgery, and between the first and the second eye surgery. No difference between ReSTOR and mono-focal IOL groups was observed at baseline. After surgery, ReSTOR treated-patients had higher coordinates on both "visual functioning and satisfaction" and "independence from glasses" factors. Findings observed on the factorial plan were supported by statistical comparisons of factorial coordinates. Both mono-focal and ReSTOR-implanted patients improved their visual functioning after bilateral cataract surgery. Moreover, ReSTOR patients reported an additional benefit in independence from glasses as well as in visual functioning and patient satisfaction.
Size Constancy in Bat Biosonar? Perceptual Interaction of Object Aperture and Distance
Heinrich, Melina; Wiegrebe, Lutz
2013-01-01
Perception and encoding of object size is an important feature of sensory systems. In the visual system object size is encoded by the visual angle (visual aperture) on the retina, but the aperture depends on the distance of the object. As object distance is not unambiguously encoded in the visual system, higher computational mechanisms are needed. This phenomenon is termed “size constancy”. It is assumed to reflect an automatic re-scaling of visual aperture with perceived object distance. Recently, it was found that in echolocating bats, the ‘sonar aperture’, i.e., the range of angles from which sound is reflected from an object back to the bat, is unambiguously perceived and neurally encoded. Moreover, it is well known that object distance is accurately perceived and explicitly encoded in bat sonar. Here, we addressed size constancy in bat biosonar, recruiting virtual-object techniques. Bats of the species Phyllostomus discolor learned to discriminate two simple virtual objects that only differed in sonar aperture. Upon successful discrimination, test trials were randomly interspersed using virtual objects that differed in both aperture and distance. It was tested whether the bats spontaneously assigned absolute width information to these objects by combining distance and aperture. The results showed that while the isolated perceptual cues encoding object width, aperture, and distance were all perceptually well resolved by the bats, the animals did not assign absolute width information to the test objects. This lack of sonar size constancy may result from the bats relying on different modalities to extract size information at different distances. Alternatively, it is conceivable that familiarity with a behaviorally relevant, conspicuous object is required for sonar size constancy, as it has been argued for visual size constancy. Based on the current data, it appears that size constancy is not necessarily an essential feature of sonar perception in bats. PMID:23630598
Size constancy in bat biosonar? Perceptual interaction of object aperture and distance.
Heinrich, Melina; Wiegrebe, Lutz
2013-01-01
Perception and encoding of object size is an important feature of sensory systems. In the visual system object size is encoded by the visual angle (visual aperture) on the retina, but the aperture depends on the distance of the object. As object distance is not unambiguously encoded in the visual system, higher computational mechanisms are needed. This phenomenon is termed "size constancy". It is assumed to reflect an automatic re-scaling of visual aperture with perceived object distance. Recently, it was found that in echolocating bats, the 'sonar aperture', i.e., the range of angles from which sound is reflected from an object back to the bat, is unambiguously perceived and neurally encoded. Moreover, it is well known that object distance is accurately perceived and explicitly encoded in bat sonar. Here, we addressed size constancy in bat biosonar, recruiting virtual-object techniques. Bats of the species Phyllostomus discolor learned to discriminate two simple virtual objects that only differed in sonar aperture. Upon successful discrimination, test trials were randomly interspersed using virtual objects that differed in both aperture and distance. It was tested whether the bats spontaneously assigned absolute width information to these objects by combining distance and aperture. The results showed that while the isolated perceptual cues encoding object width, aperture, and distance were all perceptually well resolved by the bats, the animals did not assign absolute width information to the test objects. This lack of sonar size constancy may result from the bats relying on different modalities to extract size information at different distances. Alternatively, it is conceivable that familiarity with a behaviorally relevant, conspicuous object is required for sonar size constancy, as it has been argued for visual size constancy. Based on the current data, it appears that size constancy is not necessarily an essential feature of sonar perception in bats.
Buresch, Kendra C; Ulmer, Kimberly M; Cramer, Corinne; McAnulty, Sarah; Davison, William; Mäthger, Lydia M; Hanlon, Roger T
2015-10-01
Cuttlefish use multiple camouflage tactics to evade their predators. Two common tactics are background matching (resembling the background to hinder detection) and masquerade (resembling an uninteresting or inanimate object to impede detection or recognition). We investigated how the distance and orientation of visual stimuli affected the choice of these two camouflage tactics. In the current experiments, cuttlefish were presented with three visual cues: 2D horizontal floor, 2D vertical wall, and 3D object. Each was placed at several distances: directly beneath (in a circle whose diameter was one body length (BL); at zero BL [(0BL); i.e., directly beside, but not beneath the cuttlefish]; at 1BL; and at 2BL. Cuttlefish continued to respond to 3D visual cues from a greater distance than to a horizontal or vertical stimulus. It appears that background matching is chosen when visual cues are relevant only in the immediate benthic surroundings. However, for masquerade, objects located multiple body lengths away remained relevant for choice of camouflage. © 2015 Marine Biological Laboratory.
IP-Based Video Modem Extender Requirements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pierson, L G; Boorman, T M; Howe, R E
2003-12-16
Visualization is one of the keys to understanding large complex data sets such as those generated by the large computing resources purchased and developed by the Advanced Simulation and Computing program (aka ASCI). In order to be convenient to researchers, visualization data must be distributed to offices and large complex visualization theaters. Currently, local distribution of the visual data is accomplished by distance limited modems and RGB switches that simply do not scale to hundreds of users across the local, metropolitan, and WAN distances without incurring large costs in fiber plant installation and maintenance. Wide Area application over the DOEmore » Complex is infeasible using these limited distance RGB extenders. On the other hand, Internet Protocols (IP) over Ethernet is a scalable well-proven technology that can distribute large volumes of data over these distances. Visual data has been distributed at lower resolutions over IP in industrial applications. This document describes requirements of the ASCI program in visual signal distribution for the purpose of identifying industrial partners willing to develop products to meet ASCI's needs.« less
Quality of life and near vision impairment due to functional presbyopia among rural Chinese adults.
Lu, Qing; Congdon, Nathan; He, Xiangdong; Murthy, Gudlavalleti V S; Yang, Amy; He, Wei
2011-06-13
To evaluate the impact of near-vision impairment on visual functioning and quality of life in a rural adult population in Shenyang, northern China. A population-based, cross-sectional study was conducted among persons aged 40+ years, during which functional presbyopia (correctable presenting near vision < 20/50 [N8] at 40 cm) was assessed. Near-vision-related quality of life and spectacle usage questionnaires were administered by trained interviewers to determine the degree of self-rated difficulty with near tasks. A total of 1008 respondents (91.5% of 1102 eligible persons) were examined, and 776 (78%) of completed the questionnaires (mean age, 57.0 ± 10.2 years; 63.3% women). Near-vision spectacle wearers obtained their spectacles primarily from markets (74.5%) and optical shops (21.7%), and only 1.14% from eye clinics. Among 538 (69.3%) persons with functional presbyopia, self-rated overall (distance and near) vision was worse (P < 0.001) and difficulty with activities of daily living greater (P < 0.001) than among nonpresbyopes. Odds of reporting any difficulty with daily tasks remained higher (OR = 2.32; P < 0.001) for presbyopes after adjustment for age, sex, education and distance vision. Compared to persons without presbyopia, presbyopic persons were more likely to report diminished accomplishment due to vision (P = 0.01, adjusted for age, sex, education, and distance vision.) Difficulties with activities of daily living and resulting social impediments are common due to presbyopia in this setting. Most spectacle wearers with presbyopia in rural China obtain near correction from sources that do not provide comprehensive vision care.
The BHVI-EyeMapper: peripheral refraction and aberration profiles.
Fedtke, Cathleen; Ehrmann, Klaus; Falk, Darrin; Bakaraju, Ravi C; Holden, Brien A
2014-10-01
The aim of this article was to present the optical design of a new instrument (BHVI-EyeMapper, EM), which is dedicated to rapid peripheral wavefront measurements across the visual field for distance and near, and to compare the peripheral refraction and higher-order aberration profiles obtained in myopic eyes with and without accommodation. Central and peripheral refractive errors (M, J180, and J45) and higher-order aberrations (C[3, 1], C[3, 3], and C[4, 0]) were measured in 26 myopic participants (mean [±SD] age, 20.9 [±2.0] years; mean [±SD] spherical equivalent, -3.00 [±0.90] diopters [D]) corrected for distance. Measurements were performed along the horizontal visual field with (-2.00 to -5.00 D) and without (+1.00 D fogging) accommodation. Changes as a function of accommodation were compared using tilt and curvature coefficients of peripheral refraction and aberration profiles. As accommodation increased, the relative peripheral refraction profiles of M and J180 became significantly (p < 0.05) more negative and the profile of M became significantly (p < 0.05) more asymmetric. No significant differences were found for the J45 profiles (p > 0.05). The peripheral aberration profiles of C[3, 1], C[3, 3], and C[4, 0] became significantly (p < 0.05) less asymmetric as accommodation increased, but no differences were found in the curvature. The current study showed that significant changes in peripheral refraction and higher-order aberration profiles occurred during accommodation in myopic eyes. With its extended measurement capabilities, that is, permitting rapid peripheral refraction and higher-order aberration measurements up to visual field angles of ±50 degrees for distance and near (up to -5.00 D), the EM is a new advanced instrument that may provide additional insights in the ongoing quest to understand and monitor myopia development.
The BHVI-EyeMapper: Peripheral Refraction and Aberration Profiles
Fedtke, Cathleen; Ehrmann, Klaus; Falk, Darrin; Bakaraju, Ravi C.; Holden, Brien A.
2014-01-01
ABSTRACT Purpose The aim of this article was to present the optical design of a new instrument (BHVI-EyeMapper, EM), which is dedicated to rapid peripheral wavefront measurements across the visual field for distance and near, and to compare the peripheral refraction and higher-order aberration profiles obtained in myopic eyes with and without accommodation. Methods Central and peripheral refractive errors (M, J180, and J45) and higher-order aberrations (C[3, 1], C[3, 3], and C[4, 0]) were measured in 26 myopic participants (mean [±SD] age, 20.9 [±2.0] years; mean [±SD] spherical equivalent, −3.00 [±0.90] diopters [D]) corrected for distance. Measurements were performed along the horizontal visual field with (−2.00 to −5.00 D) and without (+1.00 D fogging) accommodation. Changes as a function of accommodation were compared using tilt and curvature coefficients of peripheral refraction and aberration profiles. Results As accommodation increased, the relative peripheral refraction profiles of M and J180 became significantly (p < 0.05) more negative and the profile of M became significantly (p < 0.05) more asymmetric. No significant differences were found for the J45 profiles (p > 0.05). The peripheral aberration profiles of C[3, 1], C[3, 3], and C[4, 0] became significantly (p < 0.05) less asymmetric as accommodation increased, but no differences were found in the curvature. Conclusions The current study showed that significant changes in peripheral refraction and higher-order aberration profiles occurred during accommodation in myopic eyes. With its extended measurement capabilities, that is, permitting rapid peripheral refraction and higher-order aberration measurements up to visual field angles of ±50 degrees for distance and near (up to −5.00 D), the EM is a new advanced instrument that may provide additional insights in the ongoing quest to understand and monitor myopia development. PMID:25105690
Performance of a visuomotor walking task in an augmented reality training setting.
Haarman, Juliet A M; Choi, Julia T; Buurke, Jaap H; Rietman, Johan S; Reenalda, Jasper
2017-12-01
Visual cues can be used to train walking patterns. Here, we studied the performance and learning capacities of healthy subjects executing a high-precision visuomotor walking task, in an augmented reality training set-up. A beamer was used to project visual stepping targets on the walking surface of an instrumented treadmill. Two speeds were used to manipulate task difficulty. All participants (n = 20) had to change their step length to hit visual stepping targets with a specific part of their foot, while walking on a treadmill over seven consecutive training blocks, each block composed of 100 stepping targets. Distance between stepping targets was varied between short, medium and long steps. Training blocks could either be composed of random stepping targets (no fixed sequence was present in the distance between the stepping targets) or sequenced stepping targets (repeating fixed sequence was present). Random training blocks were used to measure non-specific learning and sequenced training blocks were used to measure sequence-specific learning. Primary outcome measures were performance (% of correct hits), and learning effects (increase in performance over the training blocks: both sequence-specific and non-specific). Secondary outcome measures were the performance and stepping-error in relation to the step length (distance between stepping target). Subjects were able to score 76% and 54% at first try for lower speed (2.3 km/h) and higher speed (3.3 km/h) trials, respectively. Performance scores did not increase over the course of the trials, nor did the subjects show the ability to learn a sequenced walking task. Subjects were better able to hit targets while increasing their step length, compared to shortening it. In conclusion, augmented reality training by use of the current set-up was intuitive for the user. Suboptimal feedback presentation might have limited the learning effects of the subjects. Copyright © 2017 Elsevier B.V. All rights reserved.
Prevalence and incidence of presbyopia in urban Southern China.
Han, Xiaotong; Lee, Pei Ying; Keel, Stuart; He, Mingguang
2018-01-24
To investigate the prevalence and incidence of presbyopia in an urban Chinese population. 1817 subjects aged ≥35 years were identified by random cluster sampling in Yuexiu District, Guangzhou, China, at baseline in 2008, and all were invited for the follow-up examination in 2014. Distance and near visual acuity (VA) tests, as well as non-cycloplegic automated refraction were performed at each examination as per standardised protocol. Participants with presenting near VA ≤20/40 were further tested with add power at a standard distance of 40 cm to obtain their best-corrected near VA. Functional presbyopia was defined as near VA under presenting distance refraction correction of <20/50 and could be improved by at least one line with add power. A total of 1191 (83.5% of the 2014 follow-up) participants were included in the current analysis with a mean (SD) age of 50.4 (9.7) years, and 52.9% were female. Prevalence of functional presbyopia at baseline was 25.2% (95% CI 21.5 to 28.9) and the 6-year incidence was 42.8% (95% CI 39.4 to 50.1). Older and more hyperopic subjects had both higher prevalence and incidence of presbyopia (P<0.001). Average presbyopic correction coverage (PCC) was 87.7% at baseline and was significantly lower in myopic participants (P=0.006). Prevalence of functional presbyopia in urban China is relatively lower along with a higher PCC compared with previous population-based rural cohorts. We identified a high presbyopia incidence, and further studies are needed to understand longitudinal presbyopia progression as well as the urban-rural gap in presbyopia to throw light on future strategic planning. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Wu, Hanzhong; Zhang, Fumin; Liu, Tingyang; Li, Jianshuang; Qu, Xinghua
2016-10-17
Two-color interferometry is powerful for the correction of the air refractive index especially in the turbulent air over long distance, since the empirical equations could introduce considerable measurement uncertainty if the environmental parameters cannot be measured with sufficient precision. In this paper, we demonstrate a method for absolute distance measurement with high-accuracy correction of air refractive index using two-color dispersive interferometry. The distances corresponding to the two wavelengths can be measured via the spectrograms captured by a CCD camera pair in real time. In the long-term experiment of the correction of air refractive index, the experimental results show a standard deviation of 3.3 × 10-8 for 12-h continuous measurement without the precise knowledge of the environmental conditions, while the variation of the air refractive index is about 2 × 10-6. In the case of absolute distance measurement, the comparison with the fringe counting interferometer shows an agreement within 2.5 μm in 12 m range.
77 FR 27852 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-11
... amblyopia in his right eye since childhood. The best corrected visual acuity in his right eye is 20/400, and..., has had amblyopia in his right eye since birth. The best corrected visual acuity in his right eye is... amblyopia in his right eye since childhood. The best corrected visual acuity in his right eye is 20/80, and...
Simulator Study of Helmet-Mounted Symbology System Concepts in Degraded Visual Environments.
Cheung, Bob; McKinley, Richard A; Steels, Brad; Sceviour, Robert; Cosman, Vaughn; Holst, Peter
2015-07-01
A sudden loss of external visual cues during critical phases of flight results in spatial disorientation. This is due to undetected horizontal and vertical drift when there is little tolerance for error and correction delay as the helicopter is close to the ground. Three helmet-mounted symbology system concepts were investigated in the simulator as potential solutions for the legacy Griffon helicopters. Thirteen Royal Canadian Air Force (RCAF) Griffon pilots were exposed to the Helmet Display Tracking System for Degraded Visual Environments (HDTS), the BrownOut Symbology System (BOSS), and the current RCAF AVS7 symbology system. For each symbology system, the pilot performed a two-stage departure and a single-stage approach. The presentation order of the symbology systems was randomized. Objective performance metrics included aircraft speed, altitude, attitude, and distance from the landing point. Subjective measurements included situation awareness, mental effort, perceived performance, perceptual cue rating, and NASA Task Load Index. Repeated measures analysis of variance and subsequent planned comparison for all the objective and subjective measurements were performed between the AVS7, HDTS, and BOSS. Our results demonstrated that HDTS and BOSS showed general improvement over AVS7 in two-stage departure. However, only HDTS performed significantly better in heading error than AVS7. During the single-stage approach, BOSS performed worse than AVS7 in heading root mean square error, and only HDTS performed significantly better in distance to landing point and approach heading than the others. Both the HDTS and BOSS possess their own limitations; however, HDTS is the pilots' preferred flight display.
Rosman, Mohamad; Hall, Reece C; Chan, Cordelia; Ang, Andy; Koh, Jane; Htoon, Hla Myint; Tan, Donald T H; Mehta, Jodhbir S
2013-07-01
To compare the efficacy, predictability, and refractive outcomes of laser in situ keratomileusis (LASIK) using 2 femtosecond platforms for flap creation. Multisurgeon single center. Clinical trial. Bilateral femtosecond LASIK was performed using the Wavelight Allegretto Eye-Q 400 Hz excimer laser system. The Visumax femtosecond platform (Group 1) was used to create the LASIK flap in 1 eye, while the Intralase femtosecond platform (Group 2) was used to create the LASIK flap in the contralateral eye. The preoperative, 1-month, and 3-month postoperative visual acuities, refraction, and contrast sensitivity in the 2 groups were compared. The study enrolled 45 patients. Three months after femtosecond LASIK, 79.5% of eyes in Group 1 and 82.1% in Group 2 achieved an uncorrected distance visual acuity of 20/20 (P=.808). The mean efficacy index was 0.97 in Group 1 and 0.98 in Group 2 at 3 months (P=.735); 89.7% of eyes in Group 1 and 84.6% of eyes in Group 2 were within ± 0.50 diopter of emmetropia at 3 months (P=.498). No eye in either group lost more than 2 lines of corrected distance visual acuity. The mean safety index at 3 months was 1.11 in Group 1 and 1.10 in Group 2 (P=.570). The results of LASIK with both femtosecond lasers were similar, and both platforms produced efficacious and predictable LASIK outcomes. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Rosenfield, Mark; Hue, Jennifer E; Huang, Rae R; Bababekova, Yuliya
2012-03-01
Computer vision syndrome (CVS) is a complex of eye and vision problems related to computer use which has been reported in up to 90% of computer users. Ocular symptoms may include asthenopia, accommodative and vergence difficulties and dry eye. Previous studies have reported that uncorrected astigmatism may have a significant impact on symptoms of CVS. However, its effect on task performance is unclear. This study recorded symptoms after a 10 min period of reading from a computer monitor either through the habitual distance refractive correction or with a supplementary -1.00 or -2.00D oblique cylinder added over these lenses in 12 young, visually-normal subjects. Additionally, the distance correction condition was repeated to assess the repeatability of the symptom questionnaire. Subjects' reading speed and accuracy were monitored during the course of the 10 min trial. There was no significant difference in reading rate or the number of errors between the three astigmatic conditions. However, a significant change in symptoms was reported with the median total symptom scores for the 0, 1 and 2D astigmatic conditions being 2.0, 6.5 and 40.0, respectively (p < 0.0001). Further, the repeatability coefficient of the total symptom score following the repeated zero astigmatism condition was ± 13.46. The presence of induced astigmatism produced a significant increase in post-task symptoms but did not affect reading rate or the number of reading errors. The correction of small astigmatic refractive errors may be important in optimizing patient comfort during computer operation. Ophthalmic & Physiological Optics © 2011 The College of Optometrists.
Intraocular Lenses for the Treatment of Age-Related Cataracts
2009-01-01
Executive Summary Objective The objective of the report is to examine the comparative effectiveness and cost-effectiveness of various intraocular lenses (IOLs) for the treatment of age-related cataracts. Clinical Need: Target Population and Condition A cataract is a hardening and clouding of the normally transparent crystalline lens that may result in a progressive loss of vision depending on its size, location and density. The condition is typically bilateral, seriously compromises visual acuity and contrast sensitivity and increases glare. Cataracts can also affect people at any age, however, they usually occur as a part of the natural aging process. The occurrence of cataracts increases with age from about 12% at age 50 years, to 60% at age 70. In general, approximately 50% of people 65 year of age or older have cataracts. Mild cataracts can be treated with a change in prescription glasses, while more serious symptoms are treated by surgical removal of the cataract and implantation of an IOL. In Ontario, the estimated prevalence of cataracts increased from 697,000 in 1992 to 947,000 in 2004 (35.9% increase, 2.4% annual increase). The number of cataract surgeries per 1,000 individuals at risk of cataract increased from 64.6 in 1992 to 140.4 in 1997 (61.9% increase, 10.1% annual increase) and continued to steadily increase to 115.7 in 2004 (10.7% increase, 5.2% increase per year). Description of Technology/Therapy IOLs are classified either as monofocal, multifocal, or accommodative. Traditionally, monofocal (i.e.. fixed focusing power) IOLs are available as replacement lenses but their implantation can cause a loss of the eye’s accommodative capability (which allows variable focusing). Patients thus usually require eyeglasses after surgery for reading and near vision tasks. Multifocal IOLs aim to improve near and distant vision and obviate the need for glasses. Potential disadvantages include reduced contrast sensitivity, halos around lights and glare. Accommodating IOLs are designed to move with ciliary body contraction during accommodation and, therefore, offer a continuous range of vision (i.e. near, intermediate and distant vision) without the need for glasses. Purported advantages over multifocal IOLs include the avoidance of haloes and no reduction in contrast sensitivity. Polymethyl methacrylate (PMMA) was the first material used in the fabrication of IOLs and has inherent ultraviolet blocking abilities. PMMA IOLs are inflexible, however, and require a larger incision for implantation compared with newer foldable silicone (hydrophobic) and acrylic (hydrophobic or hydrophilic) lenses. IOLs can be further sub-classified as being either aspheric or spheric, blue/violet filtered or non-filtered or 1- or 3-piece. Methods of Evidence-Based Analysis A literature search was conducted from January 2003 to January 2009 that included OVID MEDLINE, MEDLINE In-Process and Other Non-Indexed Citations, EMBASE, the Cumulative Index to Nursing & Allied Health Literature (CINAHL), The Cochrane Library, and the International Agency for Health Technology Assessment/Centre for Review and Dissemination. Inclusion Criteria Exclusion Criteria adult patients with age-related cataractssystematic reviews, randomized controlled trials (RCTs)primary outcomes: distance visual acuity (best corrected distance visual acuity), near visual acuity (best distance corrected near visual acuity)secondary outcomes: contrast sensitivity, depth of field, glare, quality of life, visual function, spectacle dependence, posterior capsule opacification. studies with fewer than 20 eyesIOLs for non-age related cataractsIOLs for presbyopiastudies with a mean follow-up <6monthsstudies reporting insufficient data for analysis Comparisons of Interest The primary comparison of interest was accommodative vs. multifocal vs. monofocal lenses. Secondary comparisons of interest included: tinted vs. non-tinted lenses aspheric vs. spheric lenses multipiece vs. single piece lenses biomaterial A (e.g. acrylic) vs. biomaterial B (e.g. silicone) lenses sharp vs. round edged lenses The quality of the studies was examined according to the GRADE Working Group criteria for grading quality of evidence for interventional procedures. Summary of Findings The conclusions of the systematic review of IOLs for age-related cataracts are summarized in Executive Summary Table 1. Considerations for the Ontario Health System Procedures for crystalline lens removal and IOL insertion are insured and listed in the Ontario Schedule of Benefits. If a particular lens is determined to be medically necessary for a patient, the cost of the lens is covered by the hospital budget. If the patient chooses a lens that has enhanced features, then the hospital may choose to charge an additional amount above the cost of the usual lens offered. An IOL manufacturer stated that monofocal lenses comprise approximately 95% of IOL sales in Ontario and premium lenses (e.g., multifocal/accomodative) consist of about 5% of IOL sales. A medical consultant stated that all types of lenses are currently being used in Ontario (e.g., multifocal, monofocal, accommodative, tinted, nontinted, spheric, and aspheric). Nonfoldable lenses, rarely used in routine cases, are primarily used for complicated cataract implantation situations. ES Table 1: Conclusions for the Systematic Review of IOLs for Age-Related Cataracts Comparison Conclusion GRADE Quality Multifocal vs. monofocal Objective OutcomesSignificant improvement in BDCUNVANo significant difference in BCDVAInconclusive evidence for contrast sensitivityInconclusive evidence for glareSubjective OutcomesInconclusive evidence for visual satisfactionSignificant increase in glare/halosSignificant increase in freedom from spectacles moderatemoderatelowvery lowlowlow/moderatelow/moderate Accommodative vs. multifocal/monofocal Inconclusive due to Insufficient limited evidence for any effectiveness outcome very low Hydrophilic acrylic vs. other materials (hydrophobic acrylic, silicone) Significant increase in PCO score Low Sharp edged compared to round edged Significant reduction in PCO score Low One piece compared to three piece No significant difference in PCO score low Hydrophobic acrylic compared to silicone No significant difference in PCO score moderate Aspherical modified prolate anterior surface compared to spherical No significant difference in VASignificant reduction in contrast sensitivity very lowvery low Blue light filtering compared to non blue-light filtering No significant difference in BCDVANo significant difference in contrast sensitivityNo significant difference in HRQL lowlowhigh/moderate BCDVA refers to best corrected distance visual acuity; BDCUNVA, best distance corrected unaided near visual acuity; HRQL, health related quality of life; PCO, posterior capsule opacification; VA, visual acuity. PMID:23074519
Chan, Tommy C Y; Wang, Yan; Ng, Alex L K; Zhang, Jiamei; Yu, Marco C Y; Jhanji, Vishal; Cheng, George P M
2018-06-13
To compare the astigmatic correction in high myopic astigmatism between small-incision lenticule extraction and laser in situ keratomileusis (LASIK) using vector analysis. Hong Kong Laser Eye Center, Hong Kong. Retrospective case series. Patients who had correction of myopic astigmatism of 3.0 diopters (D) or more and had either small-incision lenticule extraction or femtosecond laser-assisted LASIK were included. Only the left eye was included for analysis. Visual and refractive results were presented and compared between groups. The study comprised 105 patients (40 eyes in the small-incision lenticule extraction group and 65 eyes in the femtosecond laser-assisted LASIK group.) The mean preoperative manifest cylinder was -3.42 D ± 0.55 (SD) in the small-incision lenticule extraction group and -3.47 ± 0.49 D in the LASIK group (P = .655). At 3 months, there was no significant between-group difference in uncorrected distance visual acuity (P = .915) and manifest spherical equivalent (P = .145). Ninety percent and 95.4% of eyes were within ± 0.5 D of the attempted cylindrical correction for the small-incision lenticule extraction and LASIK group, respectively (P = .423). Vector analysis showed comparable target-induced astigmatism (P = .709), surgically induced astigmatism vector (P = .449), difference vector (P = .335), and magnitude of error (P = .413) between groups. The absolute angle of error was 1.88 ± 2.25 degrees in the small-incision lenticule extraction group and 1.37 ± 1.58 degrees in the LASIK group (P = .217). Small-incision lenticule extraction offered astigmatic correction comparable to LASIK in eyes with high myopic astigmatism. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Conjunctive and Disjunctive Extensions of the Least Squares Distance Model of Cognitive Diagnosis
ERIC Educational Resources Information Center
Dimitrov, Dimiter M.; Atanasov, Dimitar V.
2012-01-01
Many models of cognitive diagnosis, including the "least squares distance model" (LSDM), work under the "conjunctive" assumption that a correct item response occurs when all latent attributes required by the item are correctly performed. This article proposes a "disjunctive" version of the LSDM under which the correct item response occurs when "at…
Congdon, Nathan; Wang, Yunfei; Song, Yue; Choi, Kai; Zhang, Mingzhi; Zhou, Zhongxia; Xie, Zhenling; Li, Liping; Liu, Xueyu; Sharma, Abhishek; Wu, Bin; Lam, Dennis S C
2008-07-01
To evaluate visual acuity, visual function, and prevalence of refractive error among Chinese secondary-school children in a cross-sectional school-based study. Uncorrected, presenting, and best corrected visual acuity, cycloplegic autorefraction with refinement, and self-reported visual function were assessed in a random, cluster sample of rural secondary school students in Xichang, China. Among the 1892 subjects (97.3% of the consenting children, 84.7% of the total sample), mean age was 14.7 +/- 0.8 years, 51.2% were female, and 26.4% were wearing glasses. The proportion of children with uncorrected, presenting, and corrected visual disability (< or = 6/12 in the better eye) was 41.2%, 19.3%, and 0.5%, respectively. Myopia < -0.5, < -2.0, and < -6.0 D in both eyes was present in 62.3%, 31.1%, and 1.9% of the subjects, respectively. Among the children with visual disability when tested without correction, 98.7% was due to refractive error, while only 53.8% (414/770) of these children had appropriate correction. The girls had significantly (P < 0.001) more presenting visual disability and myopia < -2.0 D than did the boys. More myopic refractive error was associated with worse self-reported visual function (ANOVA trend test, P < 0.001). Visual disability in this population was common, highly correctable, and frequently uncorrected. The impact of refractive error on self-reported visual function was significant. Strategies and studies to understand and remove barriers to spectacle wear are needed.
Ferraz, Fabio H; Corrente, José E; Opromolla, Paula; Schellini, Silvana A
2014-06-25
The World Health Organization (WHO) definitions of blindness and visual impairment are widely based on best-corrected visual acuity excluding uncorrected refractive errors (URE) as a visual impairment cause. Recently, URE was included as a cause of visual impairment, thus emphasizing the burden of visual impairment due to refractive error (RE) worldwide is substantially higher. The purpose of the present study is to determine the reversal of visual impairment and blindness in the population correcting RE and possible associations between RE and individual characteristics. A cross-sectional study was conducted in nine counties of the western region of state of São Paulo, using systematic and random sampling of households between March 2004 and July 2005. Individuals aged more than 1 year old were included and were evaluated for demographic data, eye complaints, history, and eye exam, including no corrected visual acuity (NCVA), best corrected vision acuity (BCVA), automatic and manual refractive examination. The definition adopted for URE was applied to individuals with NCVA > 0.15 logMAR and BCVA ≤ 0.15 logMAR after refractive correction and unmet refractive error (UREN), individuals who had visual impairment or blindness (NCVA > 0.5 logMAR) and BCVA ≤ 0.5 logMAR after optical correction. A total of 70.2% of subjects had normal NCVA. URE was detected in 13.8%. Prevalence of 4.6% of optically reversible low vision and 1.8% of blindness reversible by optical correction were found. UREN was detected in 6.5% of individuals, more frequently observed in women over the age of 50 and in higher RE carriers. Visual impairment related to eye diseases is not reversible with spectacles. Using multivariate analysis, associations between URE and UREN with regard to sex, age and RE was observed. RE is an important cause of reversible blindness and low vision in the Brazilian population.
2014-01-01
Background The World Health Organization (WHO) definitions of blindness and visual impairment are widely based on best-corrected visual acuity excluding uncorrected refractive errors (URE) as a visual impairment cause. Recently, URE was included as a cause of visual impairment, thus emphasizing the burden of visual impairment due to refractive error (RE) worldwide is substantially higher. The purpose of the present study is to determine the reversal of visual impairment and blindness in the population correcting RE and possible associations between RE and individual characteristics. Methods A cross-sectional study was conducted in nine counties of the western region of state of São Paulo, using systematic and random sampling of households between March 2004 and July 2005. Individuals aged more than 1 year old were included and were evaluated for demographic data, eye complaints, history, and eye exam, including no corrected visual acuity (NCVA), best corrected vision acuity (BCVA), automatic and manual refractive examination. The definition adopted for URE was applied to individuals with NCVA > 0.15 logMAR and BCVA ≤ 0.15 logMAR after refractive correction and unmet refractive error (UREN), individuals who had visual impairment or blindness (NCVA > 0.5 logMAR) and BCVA ≤ 0.5 logMAR after optical correction. Results A total of 70.2% of subjects had normal NCVA. URE was detected in 13.8%. Prevalence of 4.6% of optically reversible low vision and 1.8% of blindness reversible by optical correction were found. UREN was detected in 6.5% of individuals, more frequently observed in women over the age of 50 and in higher RE carriers. Visual impairment related to eye diseases is not reversible with spectacles. Using multivariate analysis, associations between URE and UREN with regard to sex, age and RE was observed. Conclusion RE is an important cause of reversible blindness and low vision in the Brazilian population. PMID:24965318
Wu, Wenjing; Wang, Yan; Zhang, Hui; Zhang, Jiamei; Li, Hua; Dou, Rui
2016-01-01
Objective To determine whether the long-term visual outcome of small incision lenticule extraction (SMILE) surgery is consistent with the short-term results in high myopic eyes. Design Retrospective cohort study; data collected from 8 August 2011 to 31 August 2015. Setting Single refractive surgery centre. Participants A total of 156 eyes were studied: 65 eyes of 39 subjects (22 female/17 male) in the high myopic group (manifest refraction spherical equivalent (MRSE) ≥−6.0 D), and 91 eyes of 54 subjects (29 female/25 male) in the control group (MRSE <−6.0 D). The inclusion criteria were subjects who had follow-ups after 1 day, 1 week, 1 month, 3, 6 months and 1 year with the manifest refraction, uncorrected and corrected distance visual acuity (UDVA/CDVA). There were no statistically significant differences between the two groups in the subjects' gender, age, or cylindrical dioptre, preoperatively (p=0.835, p=0.055, p=0.341, respectively). Primary and secondary outcome measures UDVA, refractive stability, safety index (postoperative CDVA/preoperative CDVA), and predictability (the percentage of eyes within ±0.50 D). Results In both groups, the 1-year UDVA and safety index were significantly better than results at 1 day (high myopic group: p=0.035, p<0.001; control group: p<0.016, p<0.001); the 1-year predictability showed no significant difference with the short-term results (p=1.00 in both groups). In the high myopic eyes, the 1-year MRSE was significantly worse than the short-term result (p=0.048). To correct it, the added magnitude (D) for the high myopic eyes may equal 0.13×Attempted SE (D)−0.66 D. However, the postoperative MRSE showed no differences from 1 day to 1 year (p=0.612) in the control group. Conclusions The 1-year visual outcomes were better than the short-term results after the SMILE surgery on the visual acuity and safety. However, the high myopic eyes suffered a significant regression at 1 year, which may be corrected by adding additional magnitude to the SE for high myopic eyes. PMID:27655258
Kretz, Florian T A; Tandogan, Tamer; Khoramnia, Ramin; Auffarth, Gerd U
2015-01-01
AIM To evaluate the quality of vision in respect to high order aberrations and straylight perception after implantation of an aspheric, aberration correcting, monofocal intraocular lens (IOL). METHODS Twenty-one patients (34 eyes) aged 50 to 83y underwent cataract surgery with implantation of an aspheric, aberration correcting IOL (Tecnis ZCB00, Abbott Medical Optics). Three months after surgery they were examined for uncorrected (UDVA) and corrected distance visual acuity (CDVA), contrast sensitivity (CS) under photopic and mesopic conditions with and without glare source, ocular high order aberrations (HOA, Zywave II) and retinal straylight (C-Quant). RESULTS Postoperatively, patients achieved a postoperative CDVA of 0.0 logMAR or better in 97.1% of eyes. Mean values of high order abberations were +0.02±0.27 (primary coma components) and -0.04±0.16 (spherical aberration term). Straylight values of the C-Quant were 1.35±0.44 log which is within normal range of age matched phakic patients. The CS measurements under mesopic and photopic conditions in combination with and without glare did not show any statistical significance in the patient group observed (P≥0.28). CONCLUSION The implantation of an aspherical aberration correcting monofocal IOL after cataract surgery resulted in very low residual higher order aberration (HOA) and normal straylight. PMID:26309872
Aging and the visual perception of exocentric distance.
Norman, J Farley; Adkins, Olivia C; Norman, Hideko F; Cox, Andrea G; Rogers, Connor E
2015-04-01
The ability of 18 younger and older adults to visually perceive exocentric distances was evaluated. The observers judged the extent of fronto-parallel and in-depth spatial intervals at a variety of viewing distances from 50cm to 164.3cm. Most of the observers perceived in-depth intervals to be significantly smaller than fronto-parallel intervals, a finding that is consistent with previous studies. While none of the individual observers' judgments of exocentric distance were accurate, the judgments of the older observers were significantly more accurate than those of the younger observers. The precision of the observers' judgments across repeated trials, however, was not affected by age. The results demonstrate that increases in age can produce significant improvements in the visual ability to perceive the magnitude of exocentric distances. Copyright © 2015 Elsevier Ltd. All rights reserved.
A new calibration of the semi-empirical photometric theory for Halley and other comets
NASA Technical Reports Server (NTRS)
Newburn, R. L., Jr.
1984-01-01
The semiempirical photometric theory of gas and dust production in comets (Newburn, 1979, 1981, and 1982) is recalibrated on the basis of the 17-comet compilation of spectrophotometric data of Newburn and Spinrad (1984). The results are presented in graphs and tables, and it is shown that no corrections are required for the constant R and the function delta, but that the mixing ratios (obtained as functions of heliocentric distance) can be improved, with implications for the visual-photometric comet model. Recently calculated light curves for comet Halley are compared, and the use of the nearly identical curves of Bortle and Morris (1984) and Marcus (1983) is recommended.
Audiovisual Delay as a Novel Cue to Visual Distance.
Jaekl, Philip; Seidlitz, Jakob; Harris, Laurence R; Tadin, Duje
2015-01-01
For audiovisual sensory events, sound arrives with a delay relative to light that increases with event distance. It is unknown, however, whether humans can use these ubiquitous sound delays as an information source for distance computation. Here, we tested the hypothesis that audiovisual delays can both bias and improve human perceptual distance discrimination, such that visual stimuli paired with auditory delays are perceived as more distant and are thereby an ordinal distance cue. In two experiments, participants judged the relative distance of two repetitively displayed three-dimensional dot clusters, both presented with sounds of varying delays. In the first experiment, dot clusters presented with a sound delay were judged to be more distant than dot clusters paired with equivalent sound leads. In the second experiment, we confirmed that the presence of a sound delay was sufficient to cause stimuli to appear as more distant. Additionally, we found that ecologically congruent pairing of more distant events with a sound delay resulted in an increase in the precision of distance judgments. A control experiment determined that the sound delay duration influencing these distance judgments was not detectable, thereby eliminating decision-level influence. In sum, we present evidence that audiovisual delays can be an ordinal cue to visual distance.
Perception of Egocentric Distance during Gravitational Changes in Parabolic Flight.
Clément, Gilles; Loureiro, Nuno; Sousa, Duarte; Zandvliet, Andre
2016-01-01
We explored the effect of gravity on the perceived representation of the absolute distance of objects to the observers within the range from 1.5-6 m. Experiments were performed on board the CNES Airbus Zero-G during parabolic flights eliciting repeated exposures to short periods of microgravity (0 g), hypergravity (1.8 g), and normal gravity (1 g). Two methods for obtaining estimates of perceived egocentric distance were used: verbal reports and visually directed motion toward a memorized visual target. For the latter method, because normal walking is not possible in 0 g, blindfolded subjects translated toward the visual target by pulling on a rope with their arms. The results showed that distance estimates using both verbal reports and blind pulling were significantly different between normal gravity, microgravity, and hypergravity. Compared to the 1 g measurements, the estimates of perceived distance using blind pulling were shorter for all distances in 1.8 g, whereas in 0 g they were longer for distances up to 4 m and shorter for distances beyond. These findings suggest that gravity plays a role in both the sensorimotor system and the perceptual/cognitive system for estimating egocentric distance.
Perception of Egocentric Distance during Gravitational Changes in Parabolic Flight
Clément, Gilles; Loureiro, Nuno; Sousa, Duarte; Zandvliet, Andre
2016-01-01
We explored the effect of gravity on the perceived representation of the absolute distance of objects to the observers within the range from 1.5–6 m. Experiments were performed on board the CNES Airbus Zero-G during parabolic flights eliciting repeated exposures to short periods of microgravity (0 g), hypergravity (1.8 g), and normal gravity (1 g). Two methods for obtaining estimates of perceived egocentric distance were used: verbal reports and visually directed motion toward a memorized visual target. For the latter method, because normal walking is not possible in 0 g, blindfolded subjects translated toward the visual target by pulling on a rope with their arms. The results showed that distance estimates using both verbal reports and blind pulling were significantly different between normal gravity, microgravity, and hypergravity. Compared to the 1 g measurements, the estimates of perceived distance using blind pulling were shorter for all distances in 1.8 g, whereas in 0 g they were longer for distances up to 4 m and shorter for distances beyond. These findings suggest that gravity plays a role in both the sensorimotor system and the perceptual/cognitive system for estimating egocentric distance. PMID:27463106
Autorefraction Versus Manifest Refraction in Patients With Keratoconus.
Soeters, Nienke; Muijzer, Marc B; Molenaar, Jurrian; Godefrooij, Daniel A; Wisse, Robert P L
2018-01-01
To compare visual performance using autorefraction and manifest refraction assessments in patients with keratoconus and investigate whether autorefraction measurements lead to suboptimal visual performance. Corrected distance visual acuity (CDVA) was measured in 90 eyes of 61 patients with keratoconus with both autorefraction and manifest refraction, in a random order. Maximum keratometry (Kmax), cone location, and wavefront aberration were determined with Scheimpflug tomography. The difference between the autorefraction and manifest refraction outcomes was converted to vectors and a multivariable analysis was performed to identify potential underlying causes of this difference. A significantly better CDVA was achieved with manifest refraction (0.06 vs 0.29 logMAR [20/23 vs 20/38 Snellen], P < .001). After vector analysis, a mean difference of 4.83 diopters was found between autorefraction and manifest refraction. Increased Kmax was strongly and significantly associated with better visual performance of manifest refraction compared to autorefraction (B = 0.496, P = .002). This study showed that a superior CDVA is achieved with manifest refraction compared to autorefraction in patients with keratoconus. Furthermore, the difference between the two refraction methods increases as the cornea steepens. According to this study, autorefraction is unreliable in patients with keratoconus and should be avoided. [J Refract Surg. 2018;34(1):30-34.]. Copyright 2018, SLACK Incorporated.
What's crucial in night vision goggle simulation?
NASA Astrophysics Data System (ADS)
Kooi, Frank L.; Toet, Alexander
2005-05-01
Training is required to correctly interpret NVG imagery. Training night operations with simulated intensified imagery has great potential. Compared to direct viewing with the naked eye, intensified imagery is relatively easy to simulate and the cost of real NVG training is high (logistics, risk, civilian sleep deprivation, pollution). On the surface NVG imagery appears to have a structure similar to daylight imagery. However, in actuality its characteristics differ significantly from those of daylight imagery. As a result, NVG imagery frequently induces visual illusions. To achieve realistic training, simulated NVG imagery should at least reproduce the essential visual limitations of real NVG imagery caused by reduced resolution, reduced contrast, limited field-of-view, the absence of color, and the systems sensitivity to nearby infrared radiation. It is particularly important that simulated NVG imagery represents essential NVG visual characteristics, such as the high reflection of chlorophyll and halos. Current real-time simulation software falls short for training purposes because of an incorrect representation of shadow effects. We argue that the development of shading and shadowing merits priority to close the gap between real and simulated NVG flight conditions. Visual conspicuity can be deployed as an efficient metric to measure the 'perceptual distance' between the real NVG and the simulated NVG image.
Tactile mental body parts representation in obesity.
Scarpina, Federica; Castelnuovo, Gianluca; Molinari, Enrico
2014-12-30
Obese people׳s distortions in visually-based mental body-parts representations have been reported in previous studies, but other sensory modalities have largely been neglected. In the present study, we investigated possible differences in tactilely-based body-parts representation between an obese and a healthy-weight group; additionally we explore the possible relationship between the tactile- and the visually-based body representation. Participants were asked to estimate the distance between two tactile stimuli that were simultaneously administered on the arm or on the abdomen, in the absence of visual input. The visually-based body-parts representation was investigated by a visual imagery method in which subjects were instructed to compare the horizontal extension of body part pairs. According to the results, the obese participants overestimated the size of the tactilely-perceived distances more than the healthy-weight group when the arm, and not the abdomen, was stimulated. Moreover, they reported a lower level of accuracy than did the healthy-weight group when estimating horizontal distances relative to their bodies, confirming an inappropriate visually-based mental body representation. Our results imply that body representation disturbance in obese people is not limited to the visual mental domain, but it spreads to the tactilely perceived distances. The inaccuracy was not a generalized tendency but was body-part related. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Auditory and visual spatial impression: Recent studies of three auditoria
NASA Astrophysics Data System (ADS)
Nguyen, Andy; Cabrera, Densil
2004-10-01
Auditory spatial impression is widely studied for its contribution to auditorium acoustical quality. By contrast, visual spatial impression in auditoria has received relatively little attention in formal studies. This paper reports results from a series of experiments investigating the auditory and visual spatial impression of concert auditoria. For auditory stimuli, a fragment of an anechoic recording of orchestral music was convolved with calibrated binaural impulse responses, which had been made with the dummy head microphone at a wide range of positions in three auditoria and the sound source on the stage. For visual stimuli, greyscale photographs were used, taken at the same positions in the three auditoria, with a visual target on the stage. Subjective experiments were conducted with auditory stimuli alone, visual stimuli alone, and visual and auditory stimuli combined. In these experiments, subjects rated apparent source width, listener envelopment, intimacy and source distance (auditory stimuli), and spaciousness, envelopment, stage dominance, intimacy and target distance (visual stimuli). Results show target distance to be of primary importance in auditory and visual spatial impression-thereby providing a basis for covariance between some attributes of auditory and visual spatial impression. Nevertheless, some attributes of spatial impression diverge between the senses.
Costa, Thiago L; Costa, Marcelo F; Magalhães, Adsson; Rêgo, Gabriel G; Nagy, Balázs V; Boggio, Paulo S; Ventura, Dora F
2015-02-19
Recent research suggests that V1 plays an active role in the judgment of size and distance. Nevertheless, no research has been performed using direct brain stimulation to address this issue. We used transcranial direct-current stimulation (tDCS) to directly modulate the early stages of cortical visual processing while measuring size and distance perception with a psychophysical scaling method of magnitude estimation in a repeated-measures design. The subjects randomly received anodal, cathodal, and sham tDCS in separate sessions starting with size or distance judgment tasks. Power functions were fit to the size judgment data, whereas logarithmic functions were fit to distance judgment data. Slopes and R(2) were compared with separate repeated-measures analyses of variance with two factors: task (size vs. distance) and tDCS (anodal vs. cathodal vs. sham). Anodal tDCS significantly decreased slopes, apparently interfering with size perception. No effects were found for distance perception. Consistent with previous studies, the results of the size task appeared to reflect a prothetic continuum, whereas the results of the distance task seemed to reflect a metathetic continuum. The differential effects of tDCS on these tasks may support the hypothesis that different physiological mechanisms underlie judgments on these two continua. The results further suggest the complex involvement of the early visual cortex in size judgment tasks that go beyond the simple representation of low-level stimulus properties. This supports predictive coding models and experimental findings that suggest that higher-order visual areas may inhibit incoming information from the early visual cortex through feedback connections when complex tasks are performed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Kujala, Tuomo; Mäkelä, Jakke; Kotilainen, Ilkka; Tokkonen, Timo
2016-02-01
We studied the utility of occlusion distance as a function of task-relevant event density in realistic traffic scenarios with self-controlled speed. The visual occlusion technique is an established method for assessing visual demands of driving. However, occlusion time is not a highly informative measure of environmental task-relevant event density in self-paced driving scenarios because it partials out the effects of changes in driving speed. Self-determined occlusion times and distances of 97 drivers with varying backgrounds were analyzed in driving scenarios simulating real Finnish suburban and highway traffic environments with self-determined vehicle speed. Occlusion distances varied systematically with the expected environmental demands of the manipulated driving scenarios whereas the distributions of occlusion times remained more static across the scenarios. Systematic individual differences in the preferred occlusion distances were observed. More experienced drivers achieved better lane-keeping accuracy than inexperienced drivers with similar occlusion distances; however, driving experience was unexpectedly not a major factor for the preferred occlusion distances. Occlusion distance seems to be an informative measure for assessing task-relevant event density in realistic traffic scenarios with self-controlled speed. Occlusion time measures the visual demand of driving as the task-relevant event rate in time intervals, whereas occlusion distance measures the experienced task-relevant event density in distance intervals. The findings can be utilized in context-aware distraction mitigation systems, human-automated vehicle interaction, road speed prediction and design, as well as in the testing of visual in-vehicle tasks for inappropriate in-vehicle glancing behaviors in any dynamic traffic scenario for which appropriate individual occlusion distances can be defined. © 2015, Human Factors and Ergonomics Society.
Retinal image mosaicing using the radial distortion correction model
NASA Astrophysics Data System (ADS)
Lee, Sangyeol; Abràmoff, Michael D.; Reinhardt, Joseph M.
2008-03-01
Fundus camera imaging can be used to examine the retina to detect disorders. Similar to looking through a small keyhole into a large room, imaging the fundus with an ophthalmologic camera allows only a limited view at a time. Thus, the generation of a retinal montage using multiple images has the potential to increase diagnostic accuracy by providing larger field of view. A method of mosaicing multiple retinal images using the radial distortion correction (RADIC) model is proposed in this paper. Our method determines the inter-image connectivity by detecting feature correspondences. The connectivity information is converted to a tree structure that describes the spatial relationships between the reference and target images for pairwise registration. The montage is generated by cascading pairwise registration scheme starting from the anchor image downward through the connectivity tree hierarchy. The RADIC model corrects the radial distortion that is due to the spherical-to-planar projection during retinal imaging. Therefore, after radial distortion correction, individual images can be properly mapped onto a montage space by a linear geometric transformation, e.g. affine transform. Compared to the most existing montaging methods, our method is unique in that only a single registration per image is required because of the distortion correction property of RADIC model. As a final step, distance-weighted intensity blending is employed to correct the inter-image differences in illumination encountered when forming the montage. Visual inspection of the experimental results using three mosaicing cases shows our method can produce satisfactory montages.
Hongwarittorrn, Irin; Chaichanawongsaroj, Nuntaree; Laiwattanapaisal, Wanida
2017-12-01
A distance-based paper analytical device (dPAD) for loop mediated isothermal amplification (LAMP) detection based on distance measurement was proposed. This approach relied on visual detection by the length of colour developed on the dPAD with reference to semi-quantitative determination of the initial amount of genomic DNA. In this communication, E. coli DNA was chosen as a template DNA for LAMP reaction. In accordance with the principle, the dPAD was immobilized by polyethylenimine (PEI), which is a strong cationic polymer, in the hydrophilic channel of the paper device. Hydroxynaphthol blue (HNB), a colourimetric indicator for monitoring the change of magnesium ion concentration in the LAMP reaction, was used to react with the immobilized PEI. The positive charges of PEI react with the negative charges of free HNB in the LAMP reaction, producing a blue colour deposit on the paper device. Consequently, the apparently visual distance appeared within 5min and length of distance correlated to the amount of DNA in the sample. The distance-based PAD for the visual detection of the LAMP reaction could quantify the initial concentration of genomic DNA as low as 4.14 × 10 3 copiesµL -1 . This distance-based visual semi-quantitative platform is suitable for choice of LAMP detection method, particular in resource-limited settings because of the advantages of low cost, simple fabrication and operation, disposability and portable detection of the dPAD device. Copyright © 2017 Elsevier B.V. All rights reserved.
Tutoring math platform accessible for visually impaired people.
Maćkowski, Michał Sebastian; Brzoza, Piotr Franciszek; Spinczyk, Dominik Roland
2018-04-01
There are many problems with teaching and assessing impaired students in higher education, especially in technical science, where the knowledge is represented mostly by structural information like: math formulae, charts, graphs, etc. Developing e-learning platform for distance education solves this problem only partially due to the lack of accessibility for the blind. The proposed method is based on the decomposition of the typical mathematical exercise into a sequence of elementary sub-exercises. This allows for interactive resolving of math exercises and assessment of the correctness of exercise solutions at every stage. The presented methods were prepared and evaluated by visually impaired people and students. The article presents the accessible interactive tutoring platform for math teaching and assessment, and experience in exploring it. The results of conducted research confirm good understanding of math formulae described according to elaborated rules. Regardless of the level of complexity of the math formulae the level of math formulae understanding is higher for alternative structural description. The proposed solution enables alternative descriptions of math formulae. Based on the research results, the tool for computer-aided interactive learning of mathematics adapted to the needs of the blind has been designed, implemented and deployed as a platform for on-site and online and distance learning. The designed solution can be very helpful in overcoming many barriers that occur while teaching impaired students. Copyright © 2017 Elsevier Ltd. All rights reserved.
Rougier, P
2003-04-01
To assess to which extent the non visual somato-sensorial information may, through a recalibration process, induce a reorganisation by the central nervous system to control undisturbed upright stance. Ten healthy adults were placed in complete darkness for a 24 min period. Their postural performance was recorded through a force platform on which they were required to stand still at regular intervals. Centre of Pressure (CP) displacements, recorded from the platform, were modelled as fractional brownian motion. Through this analysis, one may objectively assess from which distance and for how long the corrective process is initiated with the aim of slowing and retrace its steps. In addition, the degree to which the CP trajectories are successively controlled was determined. Once in complete darkness, an increase of the mean time intervals (Delta(t)) before the corrective process intervenes was observed, the effect being mostly significant for the mediolateral direction. In parallel, the mean distances covered at this Delta(t) were slightly affected for both mediolateral and anteroposterior directions. Lastly, the degree to which the CP trajectories are controlled tended to decrease. These data suggest a reorganisation of the control mechanisms called into play for maintaining an undisturbed upright stance, thus implying participation of the central nervous system. This short-term adaptation is discussed on the basis of our knowledge of long term adaptations previously observed in blind individuals, and also in a rehabilitation perspective.
Adaptive optics for peripheral vision
NASA Astrophysics Data System (ADS)
Rosén, R.; Lundström, L.; Unsbo, P.
2012-07-01
Understanding peripheral optical errors and their impact on vision is important for various applications, e.g. research on myopia development and optical correction of patients with central visual field loss. In this study, we investigated whether correction of higher order aberrations with adaptive optics (AO) improve resolution beyond what is achieved with best peripheral refractive correction. A laboratory AO system was constructed for correcting peripheral aberrations. The peripheral low contrast grating resolution acuity in the 20° nasal visual field of the right eye was evaluated for 12 subjects using three types of correction: refractive correction of sphere and cylinder, static closed loop AO correction and continuous closed loop AO correction. Running AO in continuous closed loop improved acuity compared to refractive correction for most subjects (maximum benefit 0.15 logMAR). The visual improvement from aberration correction was highly correlated with the subject's initial amount of higher order aberrations (p = 0.001, R 2 = 0.72). There was, however, no acuity improvement from static AO correction. In conclusion, correction of peripheral higher order aberrations can improve low contrast resolution, provided refractive errors are corrected and the system runs in continuous closed loop.
Ivarsen, Anders; Hjortdal, Jesper Ø
2014-06-01
To report the outcome of topography-guided photorefractive keratectomy (PRK) after complicated small incision lenticule extraction (SMILE). Retrospective case series of 5 eyes with irregular topography and ghost images after complicated SMILE. All eyes received transepithelial topography-guided PRK. Two eyes were treated with 0.02% mitomycin C. Patients were examined after a minimum of 3 months with evaluation of uncorrected (UDVA) and corrected (CDVA) distance visual acuity, Pentacam tomography (Oculus Optikgeräte, Wetzlar, Germany), and whole-eye aberrometry. In 3 eyes, subjective symptoms were diminished and UDVA, CDVA, topography, and corneal wavefront aberrations were improved. The remaining 2 eyes developed significant haze with worsened topography and wavefront aberrations. One eye experienced a two-line reduction in CDVA. Eyes with haze development had not been treated with mitomycin C. Transepithelial topography-guided PRK may reduce visual symptoms after complicated SMILE if postoperative haze can be controlled. To reduce the risk of haze development, application of mitomycin C may be considered. Copyright 2014, SLACK Incorporated.
Visualization of delamination in composite materials utilizing advanced X-ray imaging techniques
NASA Astrophysics Data System (ADS)
Vavrik, D.; Jakubek, J.; Jandejsek, I.; Krejci, F.; Kumpova, I.; Zemlicka, J.
2015-04-01
This work is focused on the development of instrumental radiographic methods for detection of delaminations in layered carbon fibre reinforced plastic composites used in the aerospace industry. The main limitation of current visualisation techniques is a very limited possibility to image so-called closed delaminations in which delaminated layers are in contact practically with no physical gap. In this contribution we report the development of innovative methods for closed delamination detection using an X-ray phase contrast technique for which the distance between delamination surfaces is not relevant. The approach is based on the energetic sensitivity of phase-enhanced radiography. Based on the applied methodology, we can distinguish both closed and open delamination. Further we have demonstrated the possibility to visualise open delaminations characterised by a physical gap between delaminated layers. This delamination type was successfully identified and visualized utilizing a high resolution and computed tomography table-top technique based on proper beam-hardening effect correction.
Besseling, T H; Jose, J; Van Blaaderen, A
2015-02-01
Accurate distance measurement in 3D confocal microscopy is important for quantitative analysis, volume visualization and image restoration. However, axial distances can be distorted by both the point spread function (PSF) and by a refractive-index mismatch between the sample and immersion liquid, which are difficult to separate. Additionally, accurate calibration of the axial distances in confocal microscopy remains cumbersome, although several high-end methods exist. In this paper we present two methods to calibrate axial distances in 3D confocal microscopy that are both accurate and easily implemented. With these methods, we measured axial scaling factors as a function of refractive-index mismatch for high-aperture confocal microscopy imaging. We found that our scaling factors are almost completely linearly dependent on refractive index and that they were in good agreement with theoretical predictions that take the full vectorial properties of light into account. There was however a strong deviation with the theoretical predictions using (high-angle) geometrical optics, which predict much lower scaling factors. As an illustration, we measured the PSF of a correctly calibrated point-scanning confocal microscope and showed that a nearly index-matched, micron-sized spherical object is still significantly elongated due to this PSF, which signifies that care has to be taken when determining axial calibration or axial scaling using such particles. © 2014 The Authors Journal of Microscopy published by John Wiley & Sons Ltd on behalf of Royal Microscopical Society.
Cues to viewing distance for stereoscopic depth constancy.
Glennerster, A; Rogers, B J; Bradshaw, M F
1998-01-01
A veridical estimate of viewing distance is required in order to determine the metric structure of objects from binocular stereopsis. One example of a judgment of metric structure, which we used in our experiment, is the apparently circular cylinder task (E B Johnston, 1991 Vision Research 31 1351-1360). Most studies report underconstancy in this task when the stimulus is defined purely by binocular disparities. We examined the effect of two factors on performance: (i) the richness of the cues to viewing distance (using either a naturalistic setting with many cues to viewing distance or a condition in which the room and the monitors were obscured from view), and (ii) the range of stimulus disparities (cylinder depths) presented during an experimental run. We tested both experienced subjects (who had performed the task many times before under full-cue conditions) and naïve subjects. Depth constancy was reduced for the naïve subjects (from 62% to 46%) when the position of the monitors was obscured. Under similar conditions, the experienced subjects showed no reduction in constancy. In a second experiment, using a forced-choice method of constant stimuli, we found that depth constancy was reduced from 64% to 23% in naïve subjects and from 77% to 55% in experienced subjects when the same set of images was presented at all viewing distances rather than using a set of stimulus disparities proportional to the correct setting. One possible explanation of these results is that, under reduced-cue conditions, the range of disparities presented is used by the visual system as a cue to viewing distance.
Distance-based microfluidic quantitative detection methods for point-of-care testing.
Tian, Tian; Li, Jiuxing; Song, Yanling; Zhou, Leiji; Zhu, Zhi; Yang, Chaoyong James
2016-04-07
Equipment-free devices with quantitative readout are of great significance to point-of-care testing (POCT), which provides real-time readout to users and is especially important in low-resource settings. Among various equipment-free approaches, distance-based visual quantitative detection methods rely on reading the visual signal length for corresponding target concentrations, thus eliminating the need for sophisticated instruments. The distance-based methods are low-cost, user-friendly and can be integrated into portable analytical devices. Moreover, such methods enable quantitative detection of various targets by the naked eye. In this review, we first introduce the concept and history of distance-based visual quantitative detection methods. Then, we summarize the main methods for translation of molecular signals to distance-based readout and discuss different microfluidic platforms (glass, PDMS, paper and thread) in terms of applications in biomedical diagnostics, food safety monitoring, and environmental analysis. Finally, the potential and future perspectives are discussed.
Kasuga, Shoko; Kurata, Makiko; Liu, Meigen; Ushiba, Junichi
2015-05-01
Human's sophisticated motor learning system paradoxically interferes with motor performance when visual information is mirror-reversed (MR), because normal movement error correction further aggravates the error. This error-increasing mechanism makes performing even a simple reaching task difficult, but is overcome by alterations in the error correction rule during the trials. To isolate factors that trigger learners to change the error correction rule, we manipulated the gain of visual angular errors when participants made arm-reaching movements with mirror-reversed visual feedback, and compared the rule alteration timing between groups with normal or reduced gain. Trial-by-trial changes in the visual angular error was tracked to explain the timing of the change in the error correction rule. Under both gain conditions, visual angular errors increased under the MR transformation, and suddenly decreased after 3-5 trials with increase. The increase became degressive at different amplitude between the two groups, nearly proportional to the visual gain. The findings suggest that the alteration of the error-correction rule is not dependent on the amplitude of visual angular errors, and possibly determined by the number of trials over which the errors increased or statistical property of the environment. The current results encourage future intensive studies focusing on the exact rule-change mechanism. Copyright © 2014 Elsevier Ireland Ltd and the Japan Neuroscience Society. All rights reserved.
Holmes, Nicholas P; Dakwar, Azar R
2015-12-01
Movements aimed towards objects occasionally have to be adjusted when the object moves. These online adjustments can be very rapid, occurring in as little as 100ms. More is known about the latency and neural basis of online control of movements to visual than to auditory target objects. We examined the latency of online corrections in reaching-to-point movements to visual and auditory targets that could change side and/or modality at movement onset. Visual or auditory targets were presented on the left or right sides, and participants were instructed to reach and point to them as quickly and as accurately as possible. On half of the trials, the targets changed side at movement onset, and participants had to correct their movements to point to the new target location as quickly as possible. Given different published approaches to measuring the latency for initiating movement corrections, we examined several different methods systematically. What we describe here as the optimal methods involved fitting a straight-line model to the velocity of the correction movement, rather than using a statistical criterion to determine correction onset. In the multimodal experiment, these model-fitting methods produced significantly lower latencies for correcting movements away from the auditory targets than away from the visual targets. Our results confirm that rapid online correction is possible for auditory targets, but further work is required to determine whether the underlying control system for reaching and pointing movements is the same for auditory and visual targets. Copyright © 2015 Elsevier Ltd. All rights reserved.
Tranos, Paris; Koukoula, Stavrenia; Charteris, Davic G; Perganda, Georgia; Vakalis, Athanasios; Asteriadis, Solon; Georgalas, Ilias; Petrou, Petros
2017-06-01
To compare the anatomical and functional outcomes after primary idiopathic epiretinal membrane (ERM) peeling with or without internal limiting membrane (ILM) peeling. A two-centre randomised, controlled clinical trial with 12 months of follow-up. One hundred and two eyes of 102 patients were included in the analysis and were randomised into two groups (ILM peeling (P) and non-ILM peeling (NP) group). Inclusion criteria were: Idiopathic ERM confirmed on optical coherence tomography, age ≥18 years, binocular distortion, best-corrected visual acuity (BCVA) ≤90 ETDRS letters, intraocular pressure ≤23 mm Hg and informed consent. The primary outcome measure was the mean change in the ETDRS distance BCVA at 12 months' follow-up for each group. The mean change in distance BCVA at 12 months was 0.30±0.24 logMAR (15 ETDRS letters) in the P group and 0.31±0.23 logMAR (14 ETDRS letters) in the NP group, a change that was not statistically significant (p=0.84). No statistically significant differences were observed when comparing the changes in distance BCVA, the changes in metamorphopsia (Amsler grid) and the changes in central retinal thickness between the two groups at any of the time points studied. Our analysis suggests that ILM peeling in idiopathic ERM surgery does not result in better visual improvement. The more frequent presence of an uninterrupted interdigitation zone in the P group did not result in a better functional outcome of our patients. No recurrent ERMs were noted in either group. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
Kanellopoulos, Anastasios John
2016-01-01
To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Private clinical ophthalmology practice. A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Mean refractive error was -5.5 D of myopia and -1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over -0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B ( P <0.01). The residual percentages in both groups were measured with refractive astigmatism of more than -0.5 diopters. Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction.
Eighteen-year follow-up of hyperopic photorefractive keratectomy.
Wagh, Vijay K; Dave, Reena; O'Brart, David P S; Lim, Wei S; Patel, Parul; Tam, Connan; Lee, Jennifer; Marshall, John
2016-02-01
To investigate the long-term efficacy of hyperopic photorefractive keratectomy (PRK). University Hospital, London, United Kingdom. Prospective case series. Patients with a follow-up of 18 years ± 0.7 (SD) attended for examination. All had spherical corrections with a 6.5 mm optical zone and 1.5 mm blend zone. Twenty-five patients (45 eyes) were included. The mean preoperative spherical equivalent (SE) refractive error was +4.11 ± 1.8 diopters (D) (range +1.125 to +7.25 D). Between 1 year and 18 years, in eyes that had no cataract surgery (n = 34), there was a +1.14 ± 1.48 D increase in the mean SE (P < .0002). The increase between 7.5 years and 18.0 years did not reach clinical significance (P = .1). Uncorrected distance visual acuity improved at 18 years (P < .02). Corrected distance visual acuity (CDVA) was reduced (P < .001). The efficacy index was 0.47, and the safety index was 0.83. Six eyes (18%) lost 2 lines of CDVA, of which 4 eyes had preexisting cataract. Keratometry remained stable between 1 year and 18 years (P = .2). Forty percent still had traces of peripheral haze, and 4 (9%) had Salzmann-like changes. Eleven eyes (24%) had cataract surgery and 4 (9%) had laser iridotomy. There was no evidence of ectasia. Hyperopic PRK showed an increase in hyperopic SE between 1.0 year and 7.5 years but was generally stable thereafter. The efficacy was limited. Peripheral haze was evident in 40% of cases with Salzmann-like changes in some. Ocular comorbidity in relationship to cataract was common and reduced CDVA. Dr. Marshall was a consultant to Summit Technology, Inc. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Kanellopoulos, Anastasios John
2016-01-01
Purpose To evaluate the safety, efficacy, and contralateral eye comparison of topography-guided myopic LASIK with two different refraction treatment strategies. Setting Private clinical ophthalmology practice. Patients and methods A total of 100 eyes (50 patients) in consecutive cases of myopic topography-guided LASIK procedures with the same refractive platform (FS200 femtosecond and EX500 excimer lasers) were randomized for treatment as follows: one eye with the standard clinical refraction (group A) and the contralateral eye with the topographic astigmatic power and axis (topography-modified treatment refraction; group B). All cases were evaluated pre- and post-operatively for the following parameters: refractive error, best corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), topography (Placido-disk based) and tomography (Scheimpflug-image based), wavefront analysis, pupillometry, and contrast sensitivity. Follow-up visits were conducted for at least 12 months. Results Mean refractive error was −5.5 D of myopia and −1.75 D of astigmatism. In group A versus group B, respectively, the average UDVA improved from 20/200 to 20/20 versus 20/16; post-operative CDVA was 20/20 and 20/13.5; 1 line of vision gained was 27.8% and 55.6%; and 2 lines of vision gained was 5.6% and 11.1%. In group A, 27.8% of eyes had over −0.50 diopters of residual refractive astigmatism, in comparison to 11.7% in group B (P<0.01). The residual percentages in both groups were measured with refractive astigmatism of more than −0.5 diopters. Conclusion Topography-modified refraction (TMR): topographic adjustment of the amount and axis of astigmatism treated, when different from the clinical refraction, may offer superior outcomes in topography-guided myopic LASIK. These findings may change the current clinical paradigm of the optimal subjective refraction utilized in laser vision correction. PMID:27843292
Dai, Yun; Zhao, Lina; Xiao, Fei; Zhao, Haoxin; Bao, Hua; Zhou, Hong; Zhou, Yifeng; Zhang, Yudong
2015-02-10
An adaptive optics visual simulation combined with a perceptual learning (PL) system based on a 35-element bimorph deformable mirror (DM) was established. The larger stroke and smaller size of the bimorph DM made the system have larger aberration correction or superposition ability and be more compact. By simply modifying the control matrix or the reference matrix, select correction or superposition of aberrations was realized in real time similar to a conventional adaptive optics closed-loop correction. PL function was first integrated in addition to conventional adaptive optics visual simulation. PL training undertaken with high-order aberrations correction obviously improved the visual function of adult anisometropic amblyopia. The preliminary application of high-order aberrations correction with PL training on amblyopia treatment was being validated with a large scale population, which might have great potential in amblyopia treatment and visual performance maintenance.
NASA Technical Reports Server (NTRS)
Miller, Christopher A.; Feiveson, Al; Bloomberg, Jacob J.
2007-01-01
Toe trajectory during swing phase is a precise motor control task that can provide insights into the sensorimotor control of the legs. The purpose of this study was to determine changes in vertical toe trajectory during treadmill walking due to changes in walking speed and target distance. For each trial, subjects walked on a treadmill at one of five speeds while performing a dynamic visual acuity task at either a far or near target distance (five speeds two targets distances = ten trials). Toe clearance decreased with increasing speed, and the vertical toe peak just before heel strike increased with increasing speed, regardless of target distance. The vertical toe peak just after toe-off was lower during near-target visual acuity tasks than during far-target tasks, but was not affected by speed. The ankle of the swing leg appeared to be the main joint angle that significantly affected all three toe trajectory events. The foot angle of the swing leg significantly affected toe clearance and the toe peak just before heel strike. These results will be used to enhance the analysis of lower limb kinematics during the sensorimotor treadmill testing, where differing speeds and/or visual target distances may be used.
Visser, Nienke; Beckers, Henny J M; Bauer, Noel J C; Gast, Sacha T J M; Zijlmans, Bart L M; Berenschot, Tos T J M; Webers, Carroll A; Nuijts, Rudy M M A
2014-12-01
Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism. A multicenter, hospital-based, randomized clinical trial was conducted. The participants included 86 individuals with bilateral cataract and bilateral corneal astigmatism of at least 1.25 diopters (D) who were randomized to receive either bilateral toric (n = 41) or bilateral control (n = 45) IOL implantation. Bilateral implantation of an aspherical toric IOL or an aspherical control IOL. Spectacle independency for distance vision, uncorrected distance visual acuity, refractive astigmatism, contrast sensitivity, wavefront aberrations, and refractive error-related quality-of-life questionnaire. Preoperatively, mean (SD) corneal astigmatism was 2.02 (0.95) D and 2.00 (0.84) D in the toric and control groups, respectively. Four patients (5%) were lost to follow-up. At 6 months postoperatively, 26 (70%) of the patients in the toric group achieved an uncorrected distance visual acuity of 20/25 or better compared with 14 (31%) in the control group (P < .001; odds ratio, 5.23; 95% CI, 2.03-13.48). Spectacle independency for distance vision was achieved in 31 patients (84%) in the toric group compared with 14 patients (31%) in the control group (P < .001; odds ratio, 11.44; 95% CI, 3.89- 33.63). Mean refractive astigmatism was -0.77 (0.52) D and -1.89 D (1.00) D, respectively. Vector analysis of toric IOLs showed a mean magnitude of error of +0.38 D, indicative of overcorrection. No significant differences were found in contrast sensitivity, higher-order aberrations, or refractive error-related quality of life. In patients with cataract and corneal astigmatism, bilateral toric IOL implantation results in a higher spectacle independency for distance vision compared with bilateral control IOL implantation. No significant differences were identified in contrast sensitivity, higher-order aberrations, or refractive error-related quality of life following both treatments. clinicaltrials.gov Identifier: NCT01075542.
Lee, Kang-Hoon; Shin, Kyung-Seop; Lim, Debora; Kim, Woo-Chan; Chung, Byung Chang; Han, Gyu-Bum; Roh, Jeongkyu; Cho, Dong-Ho; Cho, Kiho
2015-07-01
The genomes of living organisms are populated with pleomorphic repetitive elements (REs) of varying densities. Our hypothesis that genomic RE landscapes are species/strain/individual-specific was implemented into the Genome Signature Imaging system to visualize and compute the RE-based signatures of any genome. Following the occurrence profiling of 5-nucleotide REs/words, the information from top-50 frequency words was transformed into a genome-specific signature and visualized as Genome Signature Images (GSIs), using a CMYK scheme. An algorithm for computing distances among GSIs was formulated using the GSIs' variables (word identity, frequency, and frequency order). The utility of the GSI-distance computation system was demonstrated with control genomes. GSI-based computation of genome-relatedness among 1766 microbes (117 archaea and 1649 bacteria) identified their clustering patterns; although the majority paralleled the established classification, some did not. The Genome Signature Imaging system, with its visualization and distance computation functions, enables genome-scale evolutionary studies involving numerous genomes with varying sizes. Copyright © 2015 Elsevier Inc. All rights reserved.
Environmental surfaces and the compression of perceived visual space
Bian, Zheng; Andersen, George J.
2011-01-01
The present study examined whether the compression of perceived visual space varies according to the type of environmental surface being viewed. To examine this issue, observers made exocentric distance judgments when viewing simulated 3D scenes. In 4 experiments, observers viewed ground and ceiling surfaces and performed either an L-shaped matching task (Experiments 1, 3, and 4) or a bisection task (Experiment 2). Overall, we found considerable compression of perceived exocentric distance on both ground and ceiling surfaces. However, the perceived exocentric distance was less compressed on a ground surface than on a ceiling surface. In addition, this ground surface advantage did not vary systematically as a function of the distance in the scene. These results suggest that the perceived visual space when viewing a ground surface is less compressed than the perceived visual space when viewing a ceiling surface and that the perceived layout of a surface varies as a function of the type of the surface. PMID:21669858
Development of an Empirical Local Magnitude Formula for Northern Oklahoma
NASA Astrophysics Data System (ADS)
Spriggs, N.; Karimi, S.; Moores, A. O.
2015-12-01
In this paper we focus on determining a local magnitude formula for northern Oklahoma that is unbiased with distance by empirically constraining the attenuation properties within the region of interest based on the amplitude of observed seismograms. For regional networks detecting events over several hundred kilometres, distance correction terms play an important role in determining the magnitude of an event. Standard distance correction terms such as Hutton and Boore (1987) may have a significant bias with distance if applied in a region with different attenuation properties, resulting in an incorrect magnitude. We have presented data from a regional network of broadband seismometers installed in bedrock in northern Oklahoma. The events with magnitude in the range of 2.0 and 4.5, distributed evenly across this network are considered. We find that existing models show a bias with respect to hypocentral distance. Observed amplitude measurements demonstrate that there is a significant Moho bounce effect that mandates the use of a trilinear attenuation model in order to avoid bias in the distance correction terms. We present two different approaches of local magnitude calibration. The first maintains the classic definition of local magnitude as proposed by Richter. The second method calibrates local magnitude so that it agrees with moment magnitude where a regional moment tensor can be computed. To this end, regional moment tensor solutions and moment magnitudes are computed for events with magnitude larger than 3.5 to allow calibration of local magnitude to moment magnitude. For both methods the new formula results in magnitudes systematically lower than previous values computed with Eaton's (1992) model. We compare the resulting magnitudes and discuss the benefits and drawbacks of each method. Our results highlight the importance of correct calibration of the distance correction terms for accurate local magnitude assessment in regional networks.
Zhao, Jing; Sun, Ling; Shen, Yang; Tian, Mi; Yao, Peijun; Zhou, Xingtao
2016-12-01
To investigate the feasibility, safety, and efficacy of using a donor lenticule created during small incision lenticule extraction (SMILE) in an epikeratophakia technique combined with phototherapeutic keratectomy (PTK). Six patients with decreased visual acuity due to a recurrence of corneal dystrophy were included in this prospective pilot study. PTK was performed using the MEL 80 excimer laser (Carl Zeiss Meditec, Jena, Germany) followed by the transplantation of donor lenticules onto the recipient eyes. These lenticules were extracted during SMILE procedures using the VisuMax femtosecond laser (Carl Zeiss Meditec) on 6 donors with myopia and served as the epikeratophakia tissue. The surgeries and postoperative follow-up examinations were uneventful and no complications were noted over 6 months of follow-up. The epithelium remodelling was achieved within 1 month. At the last measurement, the corrected distance visual acuity of all recipient eyes gained at least two lines. Five eyes (83.3%) gained at least two lines of uncorrected distance visual acuity compared to their preoperative levels. Mean keratometric power increased by 5.97 ± 3.73 diopters and central corneal thickness increased by 55.25 ± 36.38 µm. The epithelium healed and the lenticules remained clear over the follow-up period as observed under slit-lamp examination. Anterior segment optical coherence tomography observation showed the lenticule was transparent with a visible demarcation line during the follow-up examination. The use of a SMILE lenticule as a donor lenticule for an epikeratophakia technique appears feasible and safe in the short term. The predictability and long-term effects need further investigation. [J Refract Surg. 2016;32(12):840-845.]. Copyright 2016, SLACK Incorporated.
Al-Tuwairqi, Waleed; Sinjab, Mazen M
2013-01-01
To evaluate the safety and efficacy of intrastromal corneal ring segments (ICRS) implantation followed by same-day topography-guided photorefractive keratectomy (PRK) and ultraviolet-A/riboflavin collagen cross-linking (CXL) in patients with low to moderate keratoconus. Patients with low to moderate keratoconus and contact lens intolerance were included in the study. All patients first underwent femtosecond laser-enabled placement of ICRS (Keraring, Mediphacos) (first step). Same-day topography-guided PRK and CXL (second step) were subsequently performed in all patients after the refraction was stable (average 6 months [range: 3 to 11 months]). Thirteen eyes from 13 patients were included in the study. Based on values before the first step and 6 months after the second step, significant improvements were noted in uncorrected distance visual acuity (0.7±0.32 logMAR vs 0.08±0.08 logMAR), corrected distance visual acuity (CDVA) (0.16±0.19 logMAR vs 0.02±0.04 log-MAR), sphere (-3.65±3.08 diopters [D] vs 0.06±1.6 D), astigmatism (-3.31±1.5 D vs -0.98±0.75 D), average K (47.28±1.99 D vs 41.42±3.22 D), and coma (2.36±1.23 μm vs 1.47±0.68 μm) (P<.05). Approximately 63% of eyes gained ⩾2 lines of CDVA, whereas no change in CDVA was reported in ∼27% of eyes. No eyes lost lines of CDVA. The combination of ICRS implantation followed by sequential same-day topography-guided PRK/CXL may be a reasonable option for improving visual acuity in patients with low to moderate keratoconus. Copyright 2013, SLACK Incorporated.
Coskunseven, Efekan; Jankov, Mirko R; Grentzelos, Michael A; Plaka, Argyro D; Limnopoulou, Aliki N; Kymionis, George D
2013-01-01
To present the results of topography-guided transepithelial photorefractive keratectomy (PRK) after intracorneal ring segments implantation followed by corneal collagen cross-linking (CXL) for keratoconus. In this prospective case series, 10 patients (16 eyes) with progressive keratoconus were included. All patients underwent topography-guided transepithelial PRK after Keraring intracorneal ring segments (Mediphacos Ltda) implantation, followed by CXL treatment. The follow-up period was 6 months after the last procedure for all patients. Time interval between both intracorneal ring segments implantation and CXL and between CXL and topography-guided transepithelial PRK was 6 months. LogMAR mean uncorrected distance visual acuity and mean corrected distance visual acuity were significantly improved (P<.05) from 1.14±0.36 and 0.75±0.24 preoperatively to 0.25±0.13 and 0.13±0.06 after the completion of the three-step procedure, respectively. Mean spherical equivalent refraction was significantly reduced (P<.05) from -5.66±5.63 diopters (D) preoperatively to -0.98±2.21 D after the three-step procedure. Mean steep and flat keratometry values were significantly reduced (P<.05) from 54.65±5.80 D and 47.80±3.97 D preoperatively to 45.99±3.12 D and 44.69±3.19 D after the three-step procedure, respectively. Combined topography-guided transepithelial PRK with intracorneal ring segments implantation and CXL in a three-step procedure seems to be an effective, promising treatment sequence offering patients a functional visual acuity and ceasing progression of the ectatic disorder. A longer follow-up and larger case series are necessary to thoroughly evaluate safety, stability, and efficacy of this innovative procedure. Copyright 2013, SLACK Incorporated.
Alcohol versus brush PRK: visual outcomes and adverse effects.
Sia, Rose K; Ryan, Denise S; Stutzman, Richard D; Psolka, Maximilian; Mines, Michael J; Wagner, Melvin E; Weber, Eric D; Wroblewski, Keith J; Bower, Kraig S
2012-08-01
A smooth corneal surface prior to laser ablation is important in order to achieve a favorable refractive outcome. In this study, we compare PRK outcomes following two commonly used methods of epithelial debridement: Amoils epithelial scrubber (brush) versus 20% ethanol (alcohol). We reviewed records of patients who underwent wavefront-optimized PRK for myopia or myopic astigmatism between January 2008 and June 2010. Two treatment groups (brush vs. alcohol) were compared in terms of uncorrected distance visual acuity (UDVA), manifest refraction spherical equivalent (MRSE), corrected distance visual acuity (CDVA), and complications at postoperative months 1, 3, 6, and 12. One thousand five hundred ninety-three eyes of 804 patients underwent PRK during the study period: 828 brush-treated eyes and 765 alcohol-treated eyes. At 6 months postoperatively UDVA was ≥20/20 in 94.7% of brush-treated eyes versus 94.4% of alcohol-treated eyes (P = 0.907). At 1 month a higher percentage of brush-treated eyes maintained or gained one or more lines CDVA compared to alcohol-treated eyes (P = 0.007), but there were no other differences in UDVA, MRSE, or CDVA at any point postoperatively. At 1 month 75.4% of brush-treated eyes versus 70.4% of alcohol-treated eyes were free of complications (P = 0.032), and there were fewer brush-treated eyes with corneal haze (4.0% vs. 6.9%, P = 0.012) and dry eye (8.9% vs. 14.4%, P = 0.001). Although corneal haze was slightly more frequent in the alcohol group, most was trace and not significant. Although alcohol-assisted PRK had more minor complications in the early postoperative period, including corneal haze and dry eye, results for both groups beyond 1 month were comparable. Copyright © 2012 Wiley Periodicals, Inc.
Evaluating the approach run of class F11 visually impaired athletes in triple and long jumps.
Theodorou, Apostolos; Skordilis, Emmanouil
2012-04-01
The present study examined stride pattern characteristics of Class F11 visually impaired long jumpers and triple jumpers. Athletes demonstrated initial ascending footfall variability followed by descending variability, on the second (long jumpers) and third (triple jumpers) stride prior to take-off, at a mean distance of 6.26 m (long jumpers) and 7.36 m (triple jumpers) from the take-off board. Toe-board-distance variability reached a maximum value of 0.36 m and 0.38 m for the long and triple jump, respectively. Last stride toe-board-distance variability was 0.29 m (long jump) and 0.25 m (triple jump). Class F11 visually impaired athletes exhibit regulation of goal-directed gait analogous to that of non-visually impaired athletes.
Li, Wenxun; Matin, Leonard
2005-03-01
Measurements were made of the accuracy of open-loop manual pointing and height-matching to a visual target whose elevation was perceptually mislocalized. Accuracy increased linearly with distance of the hand from the body, approaching complete accuracy at full extension; with the hand close to the body (within the midfrontal plane), the manual errors equaled the magnitude of the perceptual mislocalization. The visual inducing stimulus responsible for the perceptual errors was a single pitched-from-vertical line that was long (50 degrees), eccentrically-located (25 degrees horizontal), and viewed in otherwise total darkness. The line induced perceptual errors in the elevation of a small, circular visual target set to appear at eye level (VPEL), a setting that changed linearly with the change in the line's visual pitch as has been previously reported (pitch: -30 degrees topbackward to 30 degrees topforward); the elevation errors measured by VPEL settings varied systematically with pitch through an 18 degrees range. In a fourth experiment the visual inducing stimulus responsible for the perceptual errors was shown to induce separately-measured errors in the manual setting of the arm to feel horizontal that were also distance-dependent. The distance-dependence of the visually-induced changes in felt arm position accounts quantitatively for the distance-dependence of the manual errors in pointing/reaching and height matching to the visual target: The near equality of the changes in felt horizontal and changes in pointing/reaching with the finger at the end of the fully extended arm is responsible for the manual accuracy of the fully-extended point; with the finger in the midfrontal plane their large difference is responsible for the inaccuracies of the midfrontal-plane point. The results are inconsistent with the widely-held but controversial theory that visual spatial information employed for perception and action are dissociated and different with no illusory visual influence on action. A different two-system theory, the Proximal/Distal model, employing the same signals from vision and from the body-referenced mechanism with different weights for different hand-to-body distances, accounts for both the perceptual and the manual results in the present experiments.
Frieling-Reuss, Elisabeth H
2013-10-01
To analyze and compare the postoperative visual and refractive outcomes and patients' visual satisfaction after implantation of an aspheric or an aspheric toric multifocal diffractive intraocular lens (IOL) in eyes with equivalent biometric characteristics. Private clinic, Munich, Germany. Comparative case series. Patients having cataract surgery were assigned to 1 of 2 groups: aspheric, which had AT Lisa 809M IOL implantation, and aspheric toric, which had AT Lisa 909M IOL implantation (corneal toricity ≥0.75 diopter [D]). Visual and refractive postoperative outcomes were evaluated, as was the patient's ability to perform daily tasks related to vision and the incidence of photic phenomena. The aspheric group comprised 77 eyes (42 patients) and the aspheric toric group, 26 eyes (17 patients). A significant improvement in corrected distance and near visual acuity was observed postoperatively in both groups, as was a significant reduction in the astigmatic component J0 (P<.01). The aspheric toric group had significantly better uncorrected intermediate visual acuity (P=.01). In both groups, the postoperative astigmatic power vectors and spherical equivalent were within ±0.50 D in 100% of eyes and in more than 88% of eyes, respectively. No statistically significant differences were found in any subjective patient questionnaire item. There was no difference in the incidence of photic phenomena between the groups (P≥0.16). The addition of a toric surface to the aspheric diffractive multifocal platform resulted in a comparable visual performance and ability to perform visual tasks. The author has no financial or proprietary interest in any material or method mentioned. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Arbelaez, Maria Clara; Alpins, Noel; Verma, Shwetabh; Stamatelatos, George; Arbelaez, Juan Guillermo; Arba-Mosquera, Samuel
2017-12-01
To evaluate clinical outcomes of laser in situ keratomileusis (LASIK) with an aberration-neutral profile centered on the estimated visual axis (considering 70% of the pupil offset toward the corneal vertex) comparing vector planning with manifest refraction planning for the treatment of myopic astigmatism. Muscat Eye Laser Center, Muscat, Sultanate of Oman, Muscat, Oman. Retrospective case series. The outcomes were evaluated at a 6-month follow-up in eyes showing ocular residual astigmatism (ORA) over 0.75 diopters (D) preoperatively. Eighty-five treatments were based on manifest astigmatism (preoperative sphere -2.11 D ± 1.3 [SD], cylinder -0.90 ± 1.0 D), and 79 treatments were based on vector planning (preoperative sphere -2.46 ± 1.5 D, cylinder -0.78 ± 0.79 D). At a 6-month follow-up, 128 patients (164 eyes) were evaluated and no significant differences were observed between the 2 groups in terms of difference between corrected distance visual acuity and uncorrected distance visual acuity (UDVA) (P = .1, t test and Fisher exact test Snellen lines 1 or better, P = .4) and postoperative UDVA (P = .05, t test and Fisher exact test for UDVA 20/16 or better, P = .3). Significant differences were observed between the 2 groups in terms of achieved spherical equivalent (P = .04), corneal toricity, and ORA (P < .001, t test and Fisher exact test for ORA ≤0.75 D, P < .001). Performing LASIK for myopic astigmatism with the vector planning approach resulted in comparable visual outcomes to manifest refraction planning. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Zeraid, Ferial M; Jawkhab, Asma A; Al-Tuwairqi, Waleed S; Osuagwu, Uchechukwu L
2014-01-01
AIM To present the results of same-day topography-guided photorefractive keratectomy (TG-PRK) and corneal collagen crosslinking (CXL) after previous intrastromal corneal ring segment (ISCR) implantation for keratoconus. METHODS An experimental clinical study on twenty-one eyes of 19 patients aged 27.1±6.6y (range 19-43y), with low to moderate keratoconus who were selected to undergo customized TG-PRK immediately followed by same-day CXL, 9mo after ISCR implantation in a university ophthalmology clinic. Refraction, uncorrected distance visual acuities (UDVA) and corrected distance visual acuities (CDVA), keratometry (K) values, central corneal thickness (CCT) and coma were assessed 3mo after TG-PRK and CXL. RESULTS After TG-PRK/CXL: the mean UDVA (logMAR) improved significantly from 0.66±0.41 to 0.20±0.25 (P<0.05); Kflat value decreased from: 48.44±3.66 D to 43.71±1.95 D; Ksteep value decreased from 45.61±2.40 D to 41.56±2.05 D; Kaverage also decreased from 47.00±2.66 D to 42.42±2.07 D (P<0.05 for all). The mean sphere and cylinder decreased significantly post-surgery from, -3.10±2.99 D to -0.11±0.93 D and from -3.68±1.53 to -1.11±0.75 D respectively, while the CDVA, CCT and coma showed no significant changes. Compared to post-ISCR, significant reductions (P<0.05 or all) in all K values, sphere and cylinder were observed after TG-PRK/CXL. CONCLUSION Same-day combined topography-guided PRK and corneal crosslinking following placement of ISCR is a safe and potentially effective option in treating low-moderate keratoconus. It significantly improves all visual acuity, reduced keratometry, sphere and astigmatism, but causes no change in central corneal thickness and coma. PMID:25349796
McAlinden, Colm; Skiadaresi, Eirini; Moore, Jonathan E
2011-05-01
To investigate the visual and refractive outcomes following laser-assisted subepithelial keratectomy (LASEK) surgery with a flying-spot excimer laser. Private practice, Ireland. Case series. In this prospective study, the mean manifest spherical equivalent (SE), sphere, and cylinder were measured preoperatively. All eyes had LASEK surgery with an aberration-free algorithm with the Schwind Amaris excimer laser. Outcomes measured at 1 month, 6 months, and 1 year were uncorrected distance visual acuity (UDVA), manifest refraction, corrected distance visual acuity, contrast sensitivity, aberrometry, and complications. Accuracy, efficacy, and safety were evaluated at 1 year. Preoperatively, the mean SE, sphere, and cylinder in the 80 eyes (48 patients) were -3.58 diopters (D) ± 2.00 (SD), -3.23 ± 1.93 D, and -0.85 ± 0.65 D, respectively. One year postoperatively, the mean SE was -0.00 ± 0.22 D; 57 eyes (71%) were within -0.13 to +0.13 D of the SE, and 71 eyes (98%) were within ±0.50 D. The mean UDVA was -0.06 ± 0.07 logMAR, with an efficacy index of 1.04. The postoperative SE was stable between 1 month, 3 months, and 1 year. One eye (1%) had a change in SE by more than 0.50 D at 6 months and 1 year. There were no statistically significant differences in any aberrations at 1 year. The contrast sensitivity improved from 1.66 ± 0.17 log units preoperatively to 1.72 ± 0.15 log units at 1 month postoperatively (P=.0003), which was unchanged at 6 months and 1 year. This study demonstrated the effectiveness of LASEK for the treatment of myopia with this flying-spot excimer laser. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Mohammadpour, Mehrdad; Shakoor, Delaram; Hashemi, Hassan; Aghaie Meybodi, Mohamad; Rajabi, Fateme; Hosseini, Pegah
2017-06-01
To compare the outcomes of bandage contact lens (BCL) removal on the fourth versus seventh post-operative day following photorefractive keratectomy (PRK). This study recruited eyes of patients who underwent PRK surgery. The patients were randomly assigned to 2 groups. In Group 1 BCL was removed on the 4th postoperative day, while in Group 2, BCL was removed on the 7th postoperative day. After BCL removal, patients were asked to express their pain score and eye discomfort. At one and three months follow-up examinations, visual acuity scale was assessed. Slit-lamp examination was performed in all visits to evaluate complications. 260 eyes of 130 patients underwent PRK. The age and sex ratio were not significantly different between the two groups. One month after the surgery, the logMAR uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) were significantly lower in Group 2 (P value = 0.016, 0.001 respectively), however, the UDVA and CDVA were not significantly different after 3 months (P > 0.05). In Group 1, filamentary keratitis (FK) was observed in 10 (7.6%) eyes, 6 (4.61%) eyes were diagnosed with recurrent corneal erosion (RCE) and corneal haze was detected in 3 (2.3%) eyes. However, in Group 2, RCE was observed in 4 (2.3%) and FK was noted in 4 (3.07%) eyes. No haze was seen in Group 2. The difference in rate of complications was statistically significant (14.6% and 6.1% in Groups 1 and 2, respectively, P = 0.02). Pain and eye discomfort scores were not significantly different (P > 0.05). There was no major complications including infectious keratitis in either groups. Following PRK surgery, BCL removal on the seventh postoperative day yields faster visual rehabilitation and lower rate of postoperative complications with no increase in eye pain, discomfort or infection.
Li, G; Welander, U; Yoshiura, K; Shi, X-Q; McDavid, W D
2003-11-01
Two digital image processing methods, correction for X-ray attenuation and correction for attenuation and visual response, have been developed. The aim of the present study was to compare digital radiographs before and after correction for attenuation and correction for attenuation and visual response by means of a perceptibility curve test. Radiographs were exposed of an aluminium test object containing holes ranging from 0.03 mm to 0.30 mm with increments of 0.03 mm. Fourteen radiographs were exposed with the Dixi system (Planmeca Oy, Helsinki, Finland) and twelve radiographs were exposed with the F1 iOX system (Fimet Oy, Monninkylä, Finland) from low to high exposures covering the full exposure ranges of the systems. Radiographs obtained from the Dixi and F1 iOX systems were 12 bit and 8 bit images, respectively. Original radiographs were then processed for correction for attenuation and correction for attenuation and visual response. Thus, two series of radiographs were created. Ten viewers evaluated all the radiographs in the same random order under the same viewing conditions. The object detail having the lowest perceptible contrast was recorded for each observer. Perceptibility curves were plotted according to the mean of observer data. The perceptibility curves for processed radiographs obtained with the F1 iOX system are higher than those for originals in the exposure range up to the peak, where the curves are basically the same. For radiographs exposed with the Dixi system, perceptibility curves for processed radiographs are higher than those for originals for all exposures. Perceptibility curves show that for 8 bit radiographs obtained from the F1 iOX system, the contrast threshold was increased in processed radiographs up to the peak, while for 12 bit radiographs obtained with the Dixi system, the contrast threshold was increased in processed radiographs for all exposures. When comparisons were made between radiographs corrected for attenuation and corrected for attenuation and visual response, basically no differences were found. Radiographs processed for correction for attenuation and correction for attenuation and visual response may improve perception, especially for 12 bit originals.
Badhani, Anurag; Padhi, Tapas Ranjan; Panda, Gopal Krishna; Mukherjee, Sujoy; Das, Taraprasad; Jalali, Subhadra
2017-08-01
To describe the clinical characteristics, macular structure and function, and to document sequential changes over 5 years in a 10-year-old boy with bilateral primary foveomacular retinitis. A 10-year-old boy presented with sudden onset scotoma in both eyes, experienced after getting up from bed on a non-eclipse day. He persistently denied direct sun-gazing. He neither had any significant systemic illness, nor was using any medications. In addition to a detailed examination at presentation that included fundus fluorescein angiogram (FFA), electroretinogram (ERG), pattern ERG and electrooculogram (EOG), he was examined periodically for 5 years with Humphrey visual field (HVF), spectral domain optical coherence tomogram (SDOCT), Amsler grid charting and multifocal ERG. The macular structure and functions were analyzed over the years and correlated with the symptoms. All findings were bilaterally symmetrical at each visit. At presentation, his corrected visual acuity was 20/25 with subfoveal yellow dot similar to solar retinopathy, central scotoma with reduced foveal threshold in HVF 24-2, micropsia in Amsler grid, missing of two plates on Ishihara color vision chart, transfoveal full thickness hyper-reflective band on SD OCT, unremarkable FFA and normal foveal peak in mfERG. The flash ERG and EOG were unremarkable. A month later, his VA improved to 20/20, he had relative scotoma in Amsler grid, no scotoma in HVF (10-2), restoration of the inner segment of the photoreceptors with sharp defect involving ellipsoid and photoreceptor interdigitation zone in SDOCT and blunting of foveal peaks in mfERG. Three months later, his corrected VA was 20/20 with relative scotoma in Amsler grid, normal color vision, no scotoma in HVF 10-2 and unchanged SDOCT findings. In subsequent examinations at 6, 9, 14, 29, 39 and 60 months, he was symptomless with VA 20/20, unremarkable fundus, normal Amsler grid and HVF (normal foveal threshold), unchanged SDOCT findings and the reduced foveal peaks on mfERG in both eyes got normalized only at 60 months. Presented here is a case of bilaterally symmetrical idiopathic foveomacular retinitis that had a clinical appearance similar to solar retinopathy. The fundus changes persisted for 4 weeks, the symptoms and changes in Amsler grid lasted for 3 months, and the foveal threshold in visual fields normalized within 3 months. Maximum change in the SDOCT defect occurred within a month, and the extrafoveal defect in the ellipsoid and photoreceptor interdigitation line persisted despite resolution of symptoms and resolution of the visual field defect and normal distance vision. Probably, the foveal lesion detected on SDOCT was too small to cause a reduction in the distance visual acuity or show up in the visual field and mfERG later.
DOT National Transportation Integrated Search
2013-02-01
Very little is known about the effect of motorcycle rider training on visual scanning and sight distance techniques in naturalistic riding situations. This study collected naturalistic data from a mix of novice and experienced motorcycle riders on a ...
Hirashima, Masaya
2016-01-01
Abstract When a visually guided reaching movement is unexpectedly perturbed, it is implicitly corrected in two ways: immediately after the perturbation by feedback control (online correction) and in the next movement by adjusting feedforward motor commands (offline correction or motor adaptation). Although recent studies have revealed a close relationship between feedback and feedforward controls, the nature of this relationship is not yet fully understood. Here, we show that both implicit online and offline movement corrections utilize the same visuomotor map for feedforward movement control that transforms the spatial location of visual objects into appropriate motor commands. First, we artificially distorted the visuomotor map by applying opposite visual rotations to the cursor representing the hand position while human participants reached for two different targets. This procedure implicitly altered the visuomotor map so that changes in the movement direction to the target location were more insensitive or more sensitive. Then, we examined how such visuomotor map distortion influenced online movement correction by suddenly changing the target location. The magnitude of online movement correction was altered according to the shape of the visuomotor map. We also examined offline movement correction; the aftereffect induced by visual rotation in the previous trial was modulated according to the shape of the visuomotor map. These results highlighted the importance of the visuomotor map as a foundation for implicit motor control mechanisms and the intimate relationship between feedforward control, feedback control, and motor adaptation. PMID:27275006
Hayashi, Takuji; Yokoi, Atsushi; Hirashima, Masaya; Nozaki, Daichi
2016-01-01
When a visually guided reaching movement is unexpectedly perturbed, it is implicitly corrected in two ways: immediately after the perturbation by feedback control (online correction) and in the next movement by adjusting feedforward motor commands (offline correction or motor adaptation). Although recent studies have revealed a close relationship between feedback and feedforward controls, the nature of this relationship is not yet fully understood. Here, we show that both implicit online and offline movement corrections utilize the same visuomotor map for feedforward movement control that transforms the spatial location of visual objects into appropriate motor commands. First, we artificially distorted the visuomotor map by applying opposite visual rotations to the cursor representing the hand position while human participants reached for two different targets. This procedure implicitly altered the visuomotor map so that changes in the movement direction to the target location were more insensitive or more sensitive. Then, we examined how such visuomotor map distortion influenced online movement correction by suddenly changing the target location. The magnitude of online movement correction was altered according to the shape of the visuomotor map. We also examined offline movement correction; the aftereffect induced by visual rotation in the previous trial was modulated according to the shape of the visuomotor map. These results highlighted the importance of the visuomotor map as a foundation for implicit motor control mechanisms and the intimate relationship between feedforward control, feedback control, and motor adaptation.
Distance-dependent pattern blending can camouflage salient aposematic signals.
Barnett, James B; Cuthill, Innes C; Scott-Samuel, Nicholas E
2017-07-12
The effect of viewing distance on the perception of visual texture is well known: spatial frequencies higher than the resolution limit of an observer's visual system will be summed and perceived as a single combined colour. In animal defensive colour patterns, distance-dependent pattern blending may allow aposematic patterns, salient at close range, to match the background to distant observers. Indeed, recent research has indicated that reducing the distance from which a salient signal can be detected can increase survival over camouflage or conspicuous aposematism alone. We investigated whether the spatial frequency of conspicuous and cryptically coloured stripes affects the rate of avian predation. Our results are consistent with pattern blending acting to camouflage salient aposematic signals effectively at a distance. Experiments into the relative rate of avian predation on edible model caterpillars found that increasing spatial frequency (thinner stripes) increased survival. Similarly, visual modelling of avian predators showed that pattern blending increased the similarity between caterpillar and background. These results show how a colour pattern can be tuned to reveal or conceal different information at different distances, and produce tangible survival benefits. © 2017 The Author(s).
Relating Sensitivity and Criterion Effects to the Internal Mechanisms of Visual Spatial Attention
1988-04-30
Hughes & Zimba , 1987; Rizzolatti, Riggio, Descola & *, .. Umilta, 1987). Further, deficits for uncued locations are a function 4. of the distance...Wilson, 1986; Rizzolatti, et. al., 1987; Hughes & Zimba , 1987, argue that this effect depends upon the use of an articulated visual field). Distance...Hughes, H. & Zimba , L. (1987) Nat,ral boundaries for the spatial spread of directed visual attention. Neuropsychologia, 25, 5-18. O Jonides, J. (1976
Do school classrooms meet the visual requirements of children and recommended vision standards?
Negiloni, Kalpa; Ramani, Krishna Kumar; Sudhir, Rachapalle Reddi
2017-01-01
Visual demands of school children tend to vary with diverse classroom environments. The study aimed to evaluate the distance and near Visual Acuity (VA) demand in Indian school classrooms and their comparison with the recommended vision standards. The distance and near VA demands were assessed in 33 classrooms (grades 4 to 12) of eight schools. The VA threshold demand relied on the smallest size of distance and near visual task material and viewing distance. The logMAR equivalents of minimum VA demand at specific seating positions (desk) and among different grades were evaluated. The near threshold was converted into actual near VA demand by including the acuity reserve. The existing dimensions of chalkboard and classroom, gross area in a classroom per student and class size in all the measured classrooms were compared to the government recommended standards. In 33 classrooms assessed (35±10 students per room), the average distance and near logMAR VA threshold demand was 0.31±0.17 and 0.44±0.14 respectively. The mean distance VA demand (minimum) in front desk position was 0.56±0.18 logMAR. Increased distance threshold demand (logMAR range -0.06, 0.19) was noted in 7 classrooms (21%). The mean VA demand in grades 4 to 8 and grades 9 to 12 was 0.35±0.16 and 0.24±0.16 logMAR respectively and the difference was not statistically significant (p = 0.055). The distance from board to front desk was greater than the recommended standard of 2.2m in 27 classrooms (82%). The other measured parameters were noted to be different from the proposed standards in majority of the classrooms. The study suggests the inclusion of task demand assessment in school vision screening protocol to provide relevant guidance to school authorities. These findings can serve as evidence to accommodate children with mild to moderate visual impairment in the regular classrooms.
[Refraction after Implantation of Multifocal and Presbyopia-Correcting Intraocular Lenses].
Kretz, F T A; Linz, K; Mueller, M; Gerl, M; Koss, M J; Gerl, R H; Auffarth, G U
2015-08-01
Nowadays, further developments in the field of intraocular lenses offer a higher level of spectacle independence for our patients. As light gets scattered on different focal points a wider range of defocus is created. This greater defocus area makes it more difficult for us to determine the objective or subjective refraction. This contribution is concerned with the difficulties of measuring visual acuity in different intraocular lens designs and different measurement distances. Measuring refraction after implantation of a multifocal intraocular lens is a complex procedure and the experience of the examiner plays a crucial role. Retinoscopy, keratometry and the defocus curve are reliable methods for testing, while the auto refractometer, bichromatic testing and the cross-cylinder have limitations. Georg Thieme Verlag KG Stuttgart · New York.
On Adapting the Tensor Voting Framework to Robust Color Image Denoising
NASA Astrophysics Data System (ADS)
Moreno, Rodrigo; Garcia, Miguel Angel; Puig, Domenec; Julià, Carme
This paper presents an adaptation of the tensor voting framework for color image denoising, while preserving edges. Tensors are used in order to encode the CIELAB color channels, the uniformity and the edginess of image pixels. A specific voting process is proposed in order to propagate color from a pixel to its neighbors by considering the distance between pixels, the perceptual color difference (by using an optimized version of CIEDE2000), a uniformity measurement and the likelihood of the pixels being impulse noise. The original colors are corrected with those encoded by the tensors obtained after the voting process. Peak to noise ratios and visual inspection show that the proposed methodology has a better performance than state-of-the-art techniques.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Hyun Jung; McDonnell, Kevin T.; Zelenyuk, Alla
2014-03-01
Although the Euclidean distance does well in measuring data distances within high-dimensional clusters, it does poorly when it comes to gauging inter-cluster distances. This significantly impacts the quality of global, low-dimensional space embedding procedures such as the popular multi-dimensional scaling (MDS) where one can often observe non-intuitive layouts. We were inspired by the perceptual processes evoked in the method of parallel coordinates which enables users to visually aggregate the data by the patterns the polylines exhibit across the dimension axes. We call the path of such a polyline its structure and suggest a metric that captures this structure directly inmore » high-dimensional space. This allows us to better gauge the distances of spatially distant data constellations and so achieve data aggregations in MDS plots that are more cognizant of existing high-dimensional structure similarities. Our MDS plots also exhibit similar visual relationships as the method of parallel coordinates which is often used alongside to visualize the high-dimensional data in raw form. We then cast our metric into a bi-scale framework which distinguishes far-distances from near-distances. The coarser scale uses the structural similarity metric to separate data aggregates obtained by prior classification or clustering, while the finer scale employs the appropriate Euclidean distance.« less
Dawson, Debra Ann; Lam, Jack; Lewis, Lindsay B.; Carbonell, Felix; Mendola, Janine D.
2016-01-01
Abstract Numerous studies have demonstrated functional magnetic resonance imaging (fMRI)-based resting-state functional connectivity (RSFC) between cortical areas. Recent evidence suggests that synchronous fluctuations in blood oxygenation level-dependent fMRI reflect functional organization at a scale finer than that of visual areas. In this study, we investigated whether RSFCs within and between lower visual areas are retinotopically organized and whether retinotopically organized RSFC merely reflects cortical distance. Subjects underwent retinotopic mapping and separately resting-state fMRI. Visual areas V1, V2, and V3, were subdivided into regions of interest (ROIs) according to quadrants and visual field eccentricity. Functional connectivity (FC) was computed based on Pearson's linear correlation (correlation), and Pearson's linear partial correlation (correlation between two time courses after the time courses from all other regions in the network are regressed out). Within a quadrant, within visual areas, all correlation and nearly all partial correlation FC measures showed statistical significance. Consistently in V1, V2, and to a lesser extent in V3, correlation decreased with increasing eccentricity separation. Consistent with previously reported monkey anatomical connectivity, correlation/partial correlation values between regions from adjacent areas (V1-V2 and V2-V3) were higher than those between nonadjacent areas (V1-V3). Within a quadrant, partial correlation showed consistent significance between regions from two different areas with the same or adjacent eccentricities. Pairs of ROIs with similar eccentricity showed higher correlation/partial correlation than pairs distant in eccentricity. Between dorsal and ventral quadrants, partial correlation between common and adjacent eccentricity regions within a visual area showed statistical significance; this extended to more distant eccentricity regions in V1. Within and between quadrants, correlation decreased approximately linearly with increasing distances separating the tested ROIs. Partial correlation showed a more complex dependence on cortical distance: it decreased exponentially with increasing distance within a quadrant, but was best fit by a quadratic function between quadrants. We conclude that RSFCs within and between lower visual areas are retinotopically organized. Correlation-based FC is nonselectively high across lower visual areas, even between regions that do not share direct anatomical connections. The mechanisms likely involve network effects caused by the dense anatomical connectivity within this network and projections from higher visual areas. FC based on partial correlation, which minimizes network effects, follows expectations based on direct anatomical connections in the monkey visual cortex better than correlation. Last, partial correlation-based retinotopically organized RSFC reflects more than cortical distance effects. PMID:26415043
Dawson, Debra Ann; Lam, Jack; Lewis, Lindsay B; Carbonell, Felix; Mendola, Janine D; Shmuel, Amir
2016-02-01
Numerous studies have demonstrated functional magnetic resonance imaging (fMRI)-based resting-state functional connectivity (RSFC) between cortical areas. Recent evidence suggests that synchronous fluctuations in blood oxygenation level-dependent fMRI reflect functional organization at a scale finer than that of visual areas. In this study, we investigated whether RSFCs within and between lower visual areas are retinotopically organized and whether retinotopically organized RSFC merely reflects cortical distance. Subjects underwent retinotopic mapping and separately resting-state fMRI. Visual areas V1, V2, and V3, were subdivided into regions of interest (ROIs) according to quadrants and visual field eccentricity. Functional connectivity (FC) was computed based on Pearson's linear correlation (correlation), and Pearson's linear partial correlation (correlation between two time courses after the time courses from all other regions in the network are regressed out). Within a quadrant, within visual areas, all correlation and nearly all partial correlation FC measures showed statistical significance. Consistently in V1, V2, and to a lesser extent in V3, correlation decreased with increasing eccentricity separation. Consistent with previously reported monkey anatomical connectivity, correlation/partial correlation values between regions from adjacent areas (V1-V2 and V2-V3) were higher than those between nonadjacent areas (V1-V3). Within a quadrant, partial correlation showed consistent significance between regions from two different areas with the same or adjacent eccentricities. Pairs of ROIs with similar eccentricity showed higher correlation/partial correlation than pairs distant in eccentricity. Between dorsal and ventral quadrants, partial correlation between common and adjacent eccentricity regions within a visual area showed statistical significance; this extended to more distant eccentricity regions in V1. Within and between quadrants, correlation decreased approximately linearly with increasing distances separating the tested ROIs. Partial correlation showed a more complex dependence on cortical distance: it decreased exponentially with increasing distance within a quadrant, but was best fit by a quadratic function between quadrants. We conclude that RSFCs within and between lower visual areas are retinotopically organized. Correlation-based FC is nonselectively high across lower visual areas, even between regions that do not share direct anatomical connections. The mechanisms likely involve network effects caused by the dense anatomical connectivity within this network and projections from higher visual areas. FC based on partial correlation, which minimizes network effects, follows expectations based on direct anatomical connections in the monkey visual cortex better than correlation. Last, partial correlation-based retinotopically organized RSFC reflects more than cortical distance effects.
Lipton, Brandy J; Decker, Sandra L
2016-02-01
Medicaid is the main public health insurance program for individuals with low income in the United States. Some state Medicaid programs cover preventive eye care services and vision correction, while others cover emergency eye care only. Similar to other optional benefits, states may add and drop adult vision benefits over time. This article examines whether providing adult vision benefits is associated with an increase in the percentage of low-income individuals with appropriately corrected distance vision as measured during an eye exam. We estimate the effect of Medicaid vision coverage on the likelihood of having appropriately corrected distance vision using examination data from the 2001-2008 National Health and Nutrition Examination Survey. We compare vision outcomes for Medicaid beneficiaries (n = 712) and other low income adults not enrolled in Medicaid (n = 4786) before and after changes to state vision coverage policies. Between 29 and 33 states provided Medicaid adult vision benefits during 2001-2008, depending on the year. Our findings imply that Medicaid adult vision coverage is associated with a significant increase in the percentage of Medicaid beneficiaries with appropriately corrected distance vision of up to 10 percentage points. Providing vision coverage to adults on Medicaid significantly increases the likelihood of appropriate correction of distance vision. Further research on the impact of vision coverage on related functional outcomes and the effects of Medicaid coverage of other services may be appropriate. Copyright © 2015 Elsevier Ltd. All rights reserved.
Alió Del Barrio, Jorge L; Tiveron, Mauro; Plaza-Puche, Ana B; Amesty, María A; Casanova, Laura; García, María J; Alió, Jorge L
2017-10-18
To evaluate the visual outcomes after femtosecond laser-assisted laser in situ keratomileusis (LASIK) surgery to correct primary compound hyperopic astigmatism with high cylinder using a fast repetition rate excimer laser platform with optimized aspheric profiles and cyclotorsion control. Eyes with primary simple or compound hyperopic astigmatism and a cylinder power ≥3.00 D had uneventful femtosecond laser-assisted LASIK with a fast repetition rate excimer laser ablation, aspheric profiles, and cyclotorsion control. Visual, refractive, and aberrometric results were evaluated at the 3- and 6-month follow-up. The astigmatic outcome was evaluated using the Alpins method and ASSORT software. This study enrolled 80 eyes at 3 months and 50 eyes at 6 months. The significant reduction in refractive sphere and cylinder 3 and 6 months postoperatively (p<0.01) was associated with an improved uncorrected distance visual acuity (p<0.01). A total of 23.75% required retreatment 3 months after surgery. Efficacy and safety indices at 6 months were 0.90 and 1.00, respectively. At 6 months, 80% of eyes had an SE within ±0.50 D and 96% within ±1.00 D. No significant differences were detected between the third and the sixth postoperative months in refractive parameters. A significant increase in the spherical aberration was detected, but not in coma. The correction index was 0.94 at 3 months. Laser in situ keratomileusis for primary compound hyperopic astigmatism with high cylinder (>3.00 D) using the latest excimer platforms with cyclotorsion control, fast repetition rate, and optimized aspheric profiles is safe, moderately effective, and predictable.
Management of digital eye strain.
Coles-Brennan, Chantal; Sulley, Anna; Young, Graeme
2018-05-23
Digital eye strain, an emerging public health issue, is a condition characterised by visual disturbance and/or ocular discomfort related to the use of digital devices and resulting from a range of stresses on the ocular environment. This review aims to provide an overview of the extensive literature on digital eye strain research with particular reference to the clinical management of symptoms. As many as 90 per cent of digital device users experience symptoms of digital eye strain. Many studies suggest that the following factors are associated with digital eye strain: uncorrected refractive error (including presbyopia), accommodative and vergence anomalies, altered blinking pattern (reduced rate and incomplete blinking), excessive exposure to intense light, closer working distance, and smaller font size. Since a symptom may be caused by one or more factors, a holistic approach should be adopted. The following management strategies have been suggested: (i) appropriate correction of refractive error, including astigmatism and presbyopia; (ii) management of vergence anomalies, with the aim of inducing or leaving a small amount of heterophoria (~1.5 Δ Exo); (iii) blinking exercise/training to maintain normal blinking pattern; (iv) use of lubricating eye drops (artificial tears) to help alleviate dry eye-related symptoms; (v) contact lenses with enhanced comfort, particularly at end-of-day and in challenging environments; (vi) prescription of colour filters in all vision correction options, especially blue light-absorbing filters; and (vii) management of accommodative anomalies. Prevention is the main strategy for management of digital eye strain, which involves: (i) ensuring an ergonomic work environment and practice (through patient education and the implementation of ergonomic workplace policies); and (ii) visual examination and eye care to treat visual disorders. Special consideration is needed for people at a high risk of digital eye strain, such as computer workers and contact lens wearers. © 2018 Optometry Australia.
Naël, Virginie; Pérès, Karine; Carrière, Isabelle; Daien, Vincent; Scherlen, Anne-Catherine; Arleo, Angelo; Korobelnik, Jean-Francois; Delcourt, Cécile; Helmer, Catherine
2017-04-01
As vision is required in almost all activities of daily living, visual impairment (VI) may be one of the major treatable factors for preventing activity limitations. We aimed to evaluate the attributable risk of VI associated with activity limitations and the extent to which limitations are avoidable with optimal optical correction of undercorrected refractive errors. We analyzed 709 older adults from the Three-City-Alienor population-based study. VI was defined by presenting distance visual acuity in the better-seeing eye. Multivariate modified Poisson regressions were used to estimate the associations between vision, activity limitations, and social participation restrictions. Population attributable risk (PAR) and generalized impact fraction (GIF) were estimated. Bootstrapping was used to estimate 95% confidence intervals (CI). After adjustment for potential confounders, VI was associated with each domain of activity limitations, except basic activities of daily living (ADL) limitations. These associations were found for even minimal levels of VI. PAR was estimated at 10.1% (95% CI: 5.2-10.6) for mobility limitations, at 26.0% (95% CI: 13.5-41.2) for instrumental ADL (IADL) limitations, and at 24.9% (95% CI: 10.5-47.1) for social participation restrictions. GIF for improvement of undercorrected refractive errors was 6.1% (95% CI: 3.8-8.5) for mobility limitations, 15.8% (95% CI: 11.5-20.1) for IADL limitations and 21.4% (95% CI: 13.8-28.5) for social participation restrictions. About one-sixth of IADL limitations and one-fifth of social participation restrictions could be prevented by an optimal optical correction. These results underline the importance of eye examinations in older adults to prevent disability.
Titiyal, Jeewan S; Khatik, Mukesh; Sharma, Namrata; Sehra, Sri Vatsa; Maharana, Parfulla K; Ghatak, Urmimala; Agarwal, Tushar; Khokhar, Sudarshan; Chawla, Bhavana
2014-05-01
To compare toric intraocular lens (IOL) implantation and astigmatic keratotomy (AK) in correction of astigmatism during phacoemulsification. Tertiary care hospital. Prospective randomized trial. Consecutive patients with visually significant cataract and moderate astigmatism (1.25 to 3.00 diopters [D]) were randomized into 2 groups. Temporal clear corneal 2.75 mm phacoemulsification with toric IOL implantation was performed in the toric IOL group and with 30-degree coupled AK at the 7.0 mm optic zone in the keratotomy group. The uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, keratometry, topography, central corneal thickness, and endothelial cell density were evaluated preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. The study enrolled 34 eyes (34 patients), 17 in each group. There was no difference in UDVA or CDVA between the 2 groups at any follow-up visit. The mean preoperative and postoperative refractive cylinder was 2.00 D ± 0.49 (SD) and 0.33 ± 0.17 D, respectively, in the toric IOL group and 1.95 ± 0.47 D and 0.57 ± 0.41 D, respectively, in the keratotomy group (P=.10). The mean residual astigmatism at 3 months was 0.44 ± 1.89 @ 160 in the toric IOL group and 0.77 ± 1.92 @ 174 in the keratotomy group (P=.61). All eyes in the toric IOL group and 14 eyes (84%) in the keratotomy group achieved a residual refractive cylinder of 1.00 D or less (P=.17). Toric IOL implantation was comparable to AK in eyes with moderate astigmatism having phacoemulsification. Copyright © 2014 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Perdreau, Florian; Cavanagh, Patrick
2011-01-01
Our perception starts with the image that falls on our retina and on this retinal image, distant objects are small and shadowed surfaces are dark. But this is not what we see. Visual constancies correct for distance so that, for example, a person approaching us does not appear to become a larger person. Interestingly, an artist, when rendering a scene realistically, must undo all these corrections, making distant objects again small. To determine whether years of art training and practice have conferred any specialized visual expertise, we compared the perceptual abilities of artists to those of non-artists in three tasks. We first asked them to adjust either the size or the brightness of a target to match it to a standard that was presented on a perspective grid or within a cast shadow. We instructed them to ignore the context, judging size, for example, by imagining the separation between their fingers if they were to pick up the test object from the display screen. In the third task, we tested the speed with which artists access visual representations. Subjects searched for an L-shape in contact with a circle; the target was an L-shape, but because of visual completion, it appeared to be a square occluded behind a circle, camouflaging the L-shape that is explicit on the retinal image. Surprisingly, artists were as affected by context as non-artists in all three tests. Moreover, artists took, on average, significantly more time to make their judgments, implying that they were doing their best to demonstrate the special skills that we, and they, believed they had acquired. Our data therefore support the proposal from Gombrich that artists do not have special perceptual expertise to undo the effects of constancies. Instead, once the context is present in their drawing, they need only compare the drawing to the scene to match the effect of constancies in both.
Etchemendy, Pablo E; Spiousas, Ignacio; Vergara, Ramiro
2018-01-01
In a recently published work by our group [ Scientific Reports, 7, 7189 (2017)], we performed experiments of visual distance perception in two dark rooms with extremely different reverberation times: one anechoic ( T ∼ 0.12 s) and the other reverberant ( T ∼ 4 s). The perceived distance of the targets was systematically greater in the reverberant room when contrasted to the anechoic chamber. Participants also provided auditorily perceived room-size ratings which were greater for the reverberant room. Our hypothesis was that distance estimates are affected by room size, resulting in farther responses for the room perceived larger. Of much importance to the task was the subjects' ability to infer room size from reverberation. In this article, we report a postanalysis showing that participants having musical expertise were better able to extract and translate reverberation cues into room-size information than nonmusicians. However, the degree to which musical expertise affects visual distance estimates remains unclear.
Perspective Space as a Model for Distance and Size Perception.
Erkelens, Casper J
2017-01-01
In the literature, perspective space has been introduced as a model of visual space. Perspective space is grounded on the perspective nature of visual space during both binocular and monocular vision. A single parameter, that is, the distance of the vanishing point, transforms the geometry of physical space into that of perspective space. The perspective-space model predicts perceived angles, distances, and sizes. The model is compared with other models for distance and size perception. Perspective space predicts that perceived distance and size as a function of physical distance are described by hyperbolic functions. Alternatively, power functions have been widely used to describe perceived distance and size. Comparison of power and hyperbolic functions shows that both functions are equivalent within the range of distances that have been judged in experiments. Two models describing perceived distance on the ground plane appear to be equivalent with the perspective-space model too. The conclusion is that perspective space unifies a number of models of distance and size perception.
Perspective Space as a Model for Distance and Size Perception
2017-01-01
In the literature, perspective space has been introduced as a model of visual space. Perspective space is grounded on the perspective nature of visual space during both binocular and monocular vision. A single parameter, that is, the distance of the vanishing point, transforms the geometry of physical space into that of perspective space. The perspective-space model predicts perceived angles, distances, and sizes. The model is compared with other models for distance and size perception. Perspective space predicts that perceived distance and size as a function of physical distance are described by hyperbolic functions. Alternatively, power functions have been widely used to describe perceived distance and size. Comparison of power and hyperbolic functions shows that both functions are equivalent within the range of distances that have been judged in experiments. Two models describing perceived distance on the ground plane appear to be equivalent with the perspective-space model too. The conclusion is that perspective space unifies a number of models of distance and size perception. PMID:29225765
Optimum viewing distance for target acquisition
NASA Astrophysics Data System (ADS)
Holst, Gerald C.
2015-05-01
Human visual system (HVS) "resolution" (a.k.a. visual acuity) varies with illumination level, target characteristics, and target contrast. For signage, computer displays, cell phones, and TVs a viewing distance and display size are selected. Then the number of display pixels is chosen such that each pixel subtends 1 min-1. Resolution of low contrast targets is quite different. It is best described by Barten's contrast sensitivity function. Target acquisition models predict maximum range when the display pixel subtends 3.3 min-1. The optimum viewing distance is nearly independent of magnification. Noise increases the optimum viewing distance.
The precision of locomotor odometry in humans.
Durgin, Frank H; Akagi, Mikio; Gallistel, Charles R; Haiken, Woody
2009-03-01
Two experiments measured the human ability to reproduce locomotor distances of 4.6-100 m without visual feedback and compared distance production with time production. Subjects were not permitted to count steps. It was found that the precision of human odometry follows Weber's law that variability is proportional to distance. The coefficients of variation for distance production were much lower than those measured for time production for similar durations. Gait parameters recorded during the task (average step length and step frequency) were found to be even less variable suggesting that step integration could be the basis for non-visual human odometry.
Absolute Depth Sensitivity in Cat Primary Visual Cortex under Natural Viewing Conditions.
Pigarev, Ivan N; Levichkina, Ekaterina V
2016-01-01
Mechanisms of 3D perception, investigated in many laboratories, have defined depth either relative to the fixation plane or to other objects in the visual scene. It is obvious that for efficient perception of the 3D world, additional mechanisms of depth constancy could operate in the visual system to provide information about absolute distance. Neurons with properties reflecting some features of depth constancy have been described in the parietal and extrastriate occipital cortical areas. It has also been shown that, for some neurons in the visual area V1, responses to stimuli of constant angular size differ at close and remote distances. The present study was designed to investigate whether, in natural free gaze viewing conditions, neurons tuned to absolute depths can be found in the primary visual cortex (area V1). Single-unit extracellular activity was recorded from the visual cortex of waking cats sitting on a trolley in front of a large screen. The trolley was slowly approaching the visual scene, which consisted of stationary sinusoidal gratings of optimal orientation rear-projected over the whole surface of the screen. Each neuron was tested with two gratings, with spatial frequency of one grating being twice as high as that of the other. Assuming that a cell is tuned to a spatial frequency, its maximum response to the grating with a spatial frequency twice as high should be shifted to a distance half way closer to the screen in order to attain the same size of retinal projection. For hypothetical neurons selective to absolute depth, location of the maximum response should remain at the same distance irrespective of the type of stimulus. It was found that about 20% of neurons in our experimental paradigm demonstrated sensitivity to particular distances independently of the spatial frequencies of the gratings. We interpret these findings as an indication of the use of absolute depth information in the primary visual cortex.
Clinical Outcomes after Binocular Implantation of a New Trifocal Diffractive Intraocular Lens
Kretz, Florian T. A.; Breyer, Detlev; Diakonis, Vasilios F.; Klabe, Karsten; Henke, Franziska; Auffarth, Gerd U.; Kaymak, Hakan
2015-01-01
Purpose. To evaluate visual, refractive, and contrast sensitivity outcomes, as well as the incidence of pseudophakic photic phenomena and patient satisfaction after bilateral diffractive trifocal intraocular lens (IOL) implantation. Methods. This prospective nonrandomized study included consecutive patients undergoing cataract surgery with bilateral implantation of a diffractive trifocal IOL (AT LISA tri 839MP, Carl Zeiss Meditec). Distance, intermediate, and near visual outcomes were evaluated as well as the defocus curve and the refractive outcomes 3 months after surgery. Photopic and mesopic contrast sensitivity, patient satisfaction, and halo perception were also evaluated. Results. Seventy-six eyes of 38 patients were included; 90% of eyes showed a spherical equivalent within ±0.50 diopters 3 months after surgery. All patients had a binocular uncorrected distance visual acuity of 0.00 LogMAR or better and a binocular uncorrected intermediate visual acuity of 0.10 LogMAR or better, 3 months after surgery. Furthermore, 85% of patients achieved a binocular uncorrected near visual acuity of 0.10 LogMAR or better. Conclusions. Trifocal diffractive IOL implantation seems to provide an effective restoration of visual function for far, intermediate, and near distances, providing high levels of visual quality and patient satisfaction. PMID:26301104
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Wei, E-mail: wlu@umm.edu; Neuner, Geoffrey A.; George, Rohini
2014-01-01
Purpose: To investigate whether coaching patients' breathing would improve the match between ITV{sub MIP} (internal target volume generated by contouring in the maximum intensity projection scan) and ITV{sub 10} (generated by combining the gross tumor volumes contoured in 10 phases of a 4-dimensional CT [4DCT] scan). Methods and Materials: Eight patients with a thoracic tumor and 5 patients with an abdominal tumor were included in an institutional review board-approved prospective study. Patients underwent 3 4DCT scans with: (1) free breathing (FB); (2) coaching using audio-visual (AV) biofeedback via the Real-Time Position Management system; and (3) coaching via a spirometer systemmore » (Active Breathing Coordinator or ABC). One physician contoured all scans to generate the ITV{sub 10} and ITV{sub MIP}. The match between ITV{sub MIP} and ITV{sub 10} was quantitatively assessed with volume ratio, centroid distance, root mean squared distance, and overlap/Dice coefficient. We investigated whether coaching (AV or ABC) or uniform expansions (1, 2, 3, or 5 mm) of ITV{sub MIP} improved the match. Results: Although both AV and ABC coaching techniques improved frequency reproducibility and ABC improved displacement regularity, neither improved the match between ITV{sub MIP} and ITV{sub 10} over FB. On average, ITV{sub MIP} underestimated ITV{sub 10} by 19%, 19%, and 21%, with centroid distance of 1.9, 2.3, and 1.7 mm and Dice coefficient of 0.87, 0.86, and 0.88 for FB, AV, and ABC, respectively. Separate analyses indicated a better match for lung cancers or tumors not adjacent to high-intensity tissues. Uniform expansions of ITV{sub MIP} did not correct for the mismatch between ITV{sub MIP} and ITV{sub 10}. Conclusions: In this pilot study, audio-visual biofeedback did not improve the match between ITV{sub MIP} and ITV{sub 10}. In general, ITV{sub MIP} should be limited to lung cancers, and modification of ITV{sub MIP} in each phase of the 4DCT data set is recommended.« less
Tachistoscopic exposure and masking of real three-dimensional scenes
Pothier, Stephen; Philbeck, John; Chichka, David; Gajewski, Daniel A.
2010-01-01
Although there are many well-known forms of visual cues specifying absolute and relative distance, little is known about how visual space perception develops at small temporal scales. How much time does the visual system require to extract the information in the various absolute and relative distance cues? In this article, we describe a system that may be used to address this issue by presenting brief exposures of real, three-dimensional scenes, followed by a masking stimulus. The system is composed of an electronic shutter (a liquid crystal smart window) for exposing the stimulus scene, and a liquid crystal projector coupled with an electromechanical shutter for presenting the masking stimulus. This system can be used in both full- and reduced-cue viewing conditions, under monocular and binocular viewing, and at distances limited only by the testing space. We describe a configuration that may be used for studying the microgenesis of visual space perception in the context of visually directed walking. PMID:19182129
An Ongoing Program of Radial Velocities of Nearby Stars
NASA Astrophysics Data System (ADS)
Sperauskas, J.; Boyle, R. P.; Harlow, J.; Jahreiss, H.; Upgren, A. R.
2003-12-01
The lists of stars found by Vyssotsky at the McCormick Observatory and the Fourth Edition of the Catalog of Nearby Stars (CNS4) complement each other. Each was limited in a different way, but together they can be used to evaluate sources of systematic error in either of them. The lists of Vyssotsky comprise almost 900 stars, brighter than a limiting visual magnitude of about 11.5. and thus form a magnitude-limited sample. The CNS4 includes all stars believed to be within 25 parsecs of the Sun, and thus forms a distance-limited group. Limits in magnitude are prone to the Malmquist bias by which stars of a given range in magnitude may average spuriously brighter than stars within a given distance range appropriate for the mean distance modulus. The CNS4 stars may be subject to a slight Lutz-Kelker effect. This also requires a correction that depends mainly on the ratios of the standard errors in the distances to the stars, to the distances, themselves. This is a status report on a survey seeking completeness in the six dynamical properties (positions along the three orthogonal axes, and their first time-derivatives). Parallax, proper motion and radial velocity are the stellar properties required for this information and, as is frequently the case among sets of faint stars, the radial velocities are not always available. We seek to obtain radial velocities for a full dynamical picture for more than one thousand nearby stars of which some two-thirds have been observed. It would be most desirable to follow with age-related measures for all stars
77 FR 33017 - Qualification of Drivers; Exemption Applications; Vision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-04
... complete loss of vision in his left eye due to a traumatic injury sustained at age 29. The best corrected... traumatic injury sustained in 1981. The best corrected visual acuity in his right eye is finger count vision... left eye due to a traumatic incident sustained 25 years ago. The best corrected visual acuity in his...
Distance Teaching and the Visually Handicapped: Some New Developments Using Synthetic Speech.
ERIC Educational Resources Information Center
Vincent, A. T.
1983-01-01
Distance education is important for many physically handicapped students where attendance at a conventional institution is not possible, either because of their physical condition or for reasons in common with the nonhandicapped. This paper examines an area of disability, visual handicap, and examines research into the use of microelectronic…
Line Spread as a Visual Clinical Tool for Thickened Liquids
ERIC Educational Resources Information Center
Lund, Annelise Masters; Mertz Garcia, Jane; Chambers, Edgar, IV.
2013-01-01
Purpose: Preparing modified liquids to a target level of consistency is critical to patients' nutritional care. This study examined the relationship of line spread (i.e., the distance a liquid flows) to viscometer measurements for a variety of product/liquid combinations and determined if flow distance visually differentiated nectar-thick…
The Changing Role of the Educational Video in Higher Distance Education
ERIC Educational Resources Information Center
Laaser, Wolfram; Toloza, Eduardo A.
2017-01-01
The article argues that the ongoing usage of audio visual media is falling behind in terms of educational quality compared to prior achievements in the history of distance education. After reviewing some important steps and experiences of audio visual digital media development, we analyse predominant presentation formats on the Web. Special focus…
Visual impairment and spectacle coverage rate in Baoshan district, China: population-based study
2013-01-01
Background To investigate the prevalence and risk factors of visual impairment associated with refractive error and the unmet need for spectacles in a special suburban senior population in Baoshan District of Shanghai, one of several rural areas undergoing a transition from rural to urban area, where data of visual impairment are limited. Methods The study was a population based survey of 4545 Chinese aged (age: >60 years or older ) at Baoshan, Shanghai, in 2009. One copy of questionnaire was completed for each subject. Examinations included a standardized refraction and measurement of presenting and best corrected visual acuity (BCVA) as well as tonometry, slit lamp biomicroscopy, and fundus photography. Results The prevalence of mild (6/12 to 6/18), moderate (6/18 to 6/60) and severe visual impairment was 12.59%, 8.38% and 0.44%, respectively, and 5.26%, 3.06% and 0.09% with refractive correction. Visual impairment was associated with age, gender, education and career, but not insurance . The prevalence of correctable visual impairment was 5.81% (using 6/18 cutoff) and 13.18% (using 6/12 cutoff). Senior people and women were significantly at a higher risk of correctable visual impairment, while the well-educated on the contrary. The prevalence of undercorrected refractive error (improves by 2 or more lines with refraction) was 24.84%, and the proportion with undercorrected refractive error for mild, moderate , severe and no visual impairment was 61.54%, 67.98%, 60.00% and 14.10%, respectively. The spectacle coverage rate was 44.12%. Greater unmet need for spectacles was observed among elderly people, females, non-peasant, and subjects with less education and astigmatism only. Conclusions High prevalence of visual impairment, visual impairment alleviated by refractive correction, and low spectacle coverage existed among the senior population in Baoshan District of Shanghai. Education for the public of the importance of regular examination and appropriate and accessible refraction service might be helpful to solve the problem. PMID:23566106
The visual and functional impacts of astigmatism and its clinical management.
Read, Scott A; Vincent, Stephen J; Collins, Michael J
2014-05-01
To provide a comprehensive overview of research examining the impact of astigmatism on clinical and functional measures of vision, the short and longer term adaptations to astigmatism that occur in the visual system, and the currently available clinical options for the management of patients with astigmatism. The presence of astigmatism can lead to substantial reductions in visual performance in a variety of clinical vision measures and functional visual tasks. Recent evidence demonstrates that astigmatic blur results in short-term adaptations in the visual system that appear to reduce the perceived impact of astigmatism on vision. In the longer term, uncorrected astigmatism in childhood can also significantly impact on visual development, resulting in amblyopia. Astigmatism is also associated with the development of spherical refractive errors. Although the clinical correction of small magnitudes of astigmatism is relatively straightforward, the precise, reliable correction of astigmatism (particularly high astigmatism) can be challenging. A wide variety of refractive corrections are now available for the patient with astigmatism, including spectacle, contact lens and surgical options. Astigmatism is one of the most common refractive errors managed in clinical ophthalmic practice. The significant visual and functional impacts of astigmatism emphasise the importance of its reliable clinical management. With continued improvements in ocular measurement techniques and developments in a range of different refractive correction technologies, the future promises the potential for more precise and comprehensive correction options for astigmatic patients. © 2014 The Authors Ophthalmic & Physiological Optics © 2014 The College of Optometrists.
Global magnitude of visual impairment caused by uncorrected refractive errors in 2004
Pascolini, Donatella; Mariotti, Silvio P; Pokharel, Gopal P
2008-01-01
Abstract Estimates of the prevalence of visual impairment caused by uncorrected refractive errors in 2004 have been determined at regional and global levels for people aged 5 years and over from recent published and unpublished surveys. The estimates were based on the prevalence of visual acuity of less than 6/18 in the better eye with the currently available refractive correction that could be improved to equal to or better than 6/18 by refraction or pinhole. A total of 153 million people (range of uncertainty: 123 million to 184 million) are estimated to be visually impaired from uncorrected refractive errors, of whom eight million are blind. This cause of visual impairment has been overlooked in previous estimates that were based on best-corrected vision. Combined with the 161 million people visually impaired estimated in 2002 according to best-corrected vision, 314 million people are visually impaired from all causes: uncorrected refractive errors become the main cause of low vision and the second cause of blindness. Uncorrected refractive errors can hamper performance at school, reduce employability and productivity, and generally impair quality of life. Yet the correction of refractive errors with appropriate spectacles is among the most cost-effective interventions in eye health care. The results presented in this paper help to unearth a formerly hidden problem of public health dimensions and promote policy development and implementation, programmatic decision-making and corrective interventions, as well as stimulate research. PMID:18235892
Rauch, Renate; Weingessel, Birgit; Maca, Saskia M; Vecsei-Marlovits, Pia V
2012-07-01
To determine whether the time span between initial symptoms and treatment with ranibizumab in patients with neovascular age-related macular degeneration has an effect on visual outcome. In this retrospective study, 45 patients with exudative age-related macular degeneration were split into 3 groups depending on the duration of visual symptoms--Group I: <1 month, Group II: 1 month to 6 months, and Group III: >6 months. Best-corrected visual acuity, clinical ophthalmologic examination, and central retinal thickness as measured by optical coherence tomography were recorded at baseline and 2 months later. Fluorescein angiography was performed at baseline. Treatment consisted of 2 intravitreal injections of 1.25 mg of ranibizumab at baseline and after 4 weeks. The mean time span between initial symptoms and treatment was 59 ± 62 days. In all groups, a reduction of retinal thickness was observed. Shorter disease duration, as estimated by persistence of visual symptoms, was correlated with a better visual outcome after treatment. Patients in Group I demonstrated a significant increase in best-corrected visual acuity (P = 0.007). Patients of Group II (P = 0.095) and Group III (P = 0.271) still achieved a visual improvement in best-corrected visual acuity, albeit not significant. The mean change in best-corrected visual acuity was 0.08 ± 0.1 in all patients and was not statistically significant between groups (P = 0.87). Duration of visual symptoms <1 month before treatment is associated with a better visual outcome. Treatment of new-onset wet age-related macular degeneration should be initiated as soon as possible.
Kanellopoulos, Anastasios John; Binder, Perry S
2011-05-01
To evaluate a series of patients with corneal ectasia after LASIK that underwent the Athens Protocol: combined topography-guided photorefractive keratectomy (PRK) to reduce or eliminate induced myopia and astigmatism followed by sequential, same-day ultraviolet A (UVA) corneal collagen cross-linking (CXL). Thirty-two consecutive corneal ectasia cases underwent transepithelial PRK (WaveLight ALLEGRETTO) immediately followed by CXL (3 mW/cm(2)) for 30 minutes using 0.1% topical riboflavin sodium phosphate. Uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, keratometry, central ultrasonic pachymetry, corneal tomography (Oculus Pentacam), and endothelial cell counts were analyzed. Mean follow-up was 27 months (range: 6 to 59 months). Twenty-seven of 32 eyes had an improvement in UDVA and CDVA of 20/45 or better (2.25 logMAR) at last follow-up. Four eyes showed some topographic improvement but no improvement in CDVA. One of the treated eyes required a subsequent penetrating keratoplasty. Corneal haze grade 2 was present in 2 eyes. Combined, same-day, topography-guided PRK and CXL appeared to offer tomographic stability, even after long-term follow-up. Only 2 of 32 eyes had corneal ectasia progression after the intervention. Seventeen of 32 eyes appeared to have improvement in UDVA and CDVA with follow-up >1.5 years. This technique may offer an alternative in the management of iatrogenic corneal ectasia. Copyright 2011, SLACK Incorporated.
Altinbay, Deniz; Adibelli, Fatih Mehmet; Taskin, Ibrahim; Tekin, Adil
2016-01-01
To evaluate the reading performance using the Minnesota low vision reading (MNREAD) charts, of patients with age-related macular degeneration (AMD) who use low vision aid (LVA) devices. This prospective study enrolled 27 patients with AMD. Distance visual acuity (VA) was evaluated with a distance chart designed for patients with low vision. Near vision and reading performance were evaluated with the Turkish version of the MNREAD charts. Unaided vision and vision with LVA devices and high spherical add near glasses was measured. P <0.05 was considered statistically significant. The mean unaided near VA was 1.05 ± 0.27 log of the minimum angle of resolution (LogMAR). The mean VA with the LVA devices was 0.71 ± 0.41 LogMAR. Reading acuity ranged between 1.15 and 0.21 LogMAR, critical print size was between - 1.2 and 0.2 LogMAR. Maximum reading speeds were between 0 and 103 words/min. The cases are divided into groups in terms of reading speed according to age, gender, diagnosis, and education. Reading speed was negatively correlated to increasing age. MNREAD reading charts can be used to evaluate reading performance in patients with AMD with low vision. The outcomes of the present study indicate that optical correction is adequate for near VA requirements in this patient population. However, optical correction was inadequate for improving reading performance. Appropriate rehabilitation programs can be used to increase reading speed.
The paradoxical moon illusions.
Gilinsky, A S
1980-02-01
An adaptation theory of visual space is developed and applied to the data of a variety of studies of visual space perception. By distinguishing between the perceived distance of an object and that of the background or sky, the theory resolves the paradox of the moon illusions and relates both perceived size and perceived distance of the moon to the absolute level of spatial adaptation. The theory assumes that visual space expands or contracts in adjustment to changes in the sensory indicators of depth and provides a measure, A, of this adaptation-level. Changes in A have two effects--one on perceived size, one on perceived distance. Since A varies systematically as a function of angle of regard, availability of cues, and the total space-value, A is a measure of the moon illusions, and a practical index of individual differences by pilots and astronauts in the perception of the size and distance of objects on the ground and in the air.
Three-dimensional ocular kinematics underlying binocular single vision
Misslisch, H.
2016-01-01
We have analyzed the binocular coordination of the eyes during far-to-near refixation saccades based on the evaluation of distance ratios and angular directions of the projected target images relative to the eyes' rotation centers. By defining the geometric point of binocular single vision, called Helmholtz point, we found that disparities during fixations of targets at near distances were limited in the subject's three-dimensional visual field to the vertical and forward directions. These disparities collapsed to simple vertical disparities in the projective binocular image plane. Subjects were able to perfectly fuse the vertically disparate target images with respect to the projected Helmholtz point of single binocular vision, independent of the particular location relative to the horizontal plane of regard. Target image fusion was achieved by binocular torsion combined with corrective modulations of the differential half-vergence angles of the eyes in the horizontal plane. Our findings support the notion that oculomotor control combines vergence in the horizontal plane of regard with active torsion in the frontal plane to achieve fusion of the dichoptic binocular target images. PMID:27655969
Role of the posterior parietal cortex in updating reaching movements to a visual target.
Desmurget, M; Epstein, C M; Turner, R S; Prablanc, C; Alexander, G E; Grafton, S T
1999-06-01
The exact role of posterior parietal cortex (PPC) in visually directed reaching is unknown. We propose that, by building an internal representation of instantaneous hand location, PPC computes a dynamic motor error used by motor centers to correct the ongoing trajectory. With unseen right hands, five subjects pointed to visual targets that either remained stationary or moved during saccadic eye movements. Transcranial magnetic stimulation (TMS) was applied over the left PPC during target presentation. Stimulation disrupted path corrections that normally occur in response to target jumps, but had no effect on those directed at stationary targets. Furthermore, left-hand movement corrections were not blocked, ruling out visual or oculomotor effects of stimulation.
49 CFR 325.75 - Ground surface correction factors. 1
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Ground surface correction factors. 1 325.75... MOTOR CARRIER NOISE EMISSION STANDARDS Correction Factors § 325.75 Ground surface correction factors. 1... account both the distance correction factors contained in § 325.73 and the ground surface correction...
49 CFR 325.75 - Ground surface correction factors. 1
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Ground surface correction factors. 1 325.75... MOTOR CARRIER NOISE EMISSION STANDARDS Correction Factors § 325.75 Ground surface correction factors. 1... account both the distance correction factors contained in § 325.73 and the ground surface correction...
Nekolova, Jana; Rozsival, Pavel; Sin, Martin; Jiraskova, Nada
2017-06-01
To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.
Systematic distortions of perceptual stability investigated using immersive virtual reality
Tcheang, Lili; Gilson, Stuart J.; Glennerster, Andrew
2010-01-01
Using an immersive virtual reality system, we measured the ability of observers to detect the rotation of an object when its movement was yoked to the observer's own translation. Most subjects had a large bias such that a static object appeared to rotate away from them as they moved. Thresholds for detecting target rotation were similar to those for an equivalent speed discrimination task carried out by static observers, suggesting that visual discrimination is the predominant limiting factor in detecting target rotation. Adding a stable visual reference frame almost eliminated the bias. Varying the viewing distance of the target had little effect, consistent with observers under-estimating distance walked. However, accuracy of walking to a briefly presented visual target was high and not consistent with an under-estimation of distance walked. We discuss implications for theories of a task-independent representation of visual space. PMID:15845248
Deep Multimodal Distance Metric Learning Using Click Constraints for Image Ranking.
Yu, Jun; Yang, Xiaokang; Gao, Fei; Tao, Dacheng
2017-12-01
How do we retrieve images accurately? Also, how do we rank a group of images precisely and efficiently for specific queries? These problems are critical for researchers and engineers to generate a novel image searching engine. First, it is important to obtain an appropriate description that effectively represent the images. In this paper, multimodal features are considered for describing images. The images unique properties are reflected by visual features, which are correlated to each other. However, semantic gaps always exist between images visual features and semantics. Therefore, we utilize click feature to reduce the semantic gap. The second key issue is learning an appropriate distance metric to combine these multimodal features. This paper develops a novel deep multimodal distance metric learning (Deep-MDML) method. A structured ranking model is adopted to utilize both visual and click features in distance metric learning (DML). Specifically, images and their related ranking results are first collected to form the training set. Multimodal features, including click and visual features, are collected with these images. Next, a group of autoencoders is applied to obtain initially a distance metric in different visual spaces, and an MDML method is used to assign optimal weights for different modalities. Next, we conduct alternating optimization to train the ranking model, which is used for the ranking of new queries with click features. Compared with existing image ranking methods, the proposed method adopts a new ranking model to use multimodal features, including click features and visual features in DML. We operated experiments to analyze the proposed Deep-MDML in two benchmark data sets, and the results validate the effects of the method.
Young children's coding and storage of visual and verbal material.
Perlmutter, M; Myers, N A
1975-03-01
36 preschool children (mean age 4.2 years) were each tested on 3 recognition memory lists differing in test mode (visual only, verbal only, combined visual-verbal). For one-third of the children, original list presentation was visual only, for another third, presentation was verbal only, and the final third received combined visual-verbal presentation. The subjects generally performed at a high level of correct responding. Verbal-only presentation resulted in less correct recognition than did either visual-only or combined visual-verbal presentation. However, because performances under both visual-only and combined visual-verbal presentation were statistically comparable, and a high level of spontaneous labeling was observed when items were presented only visually, a dual-processing conceptualization of memory in 4-year-olds was suggested.
Real-time distortion correction for visual inspection systems based on FPGA
NASA Astrophysics Data System (ADS)
Liang, Danhua; Zhang, Zhaoxia; Chen, Xiaodong; Yu, Daoyin
2008-03-01
Visual inspection is a kind of new technology based on the research of computer vision, which focuses on the measurement of the object's geometry and location. It can be widely used in online measurement, and other real-time measurement process. Because of the defects of the traditional visual inspection, a new visual detection mode -all-digital intelligent acquisition and transmission is presented. The image processing, including filtering, image compression, binarization, edge detection and distortion correction, can be completed in the programmable devices -FPGA. As the wide-field angle lens is adopted in the system, the output images have serious distortion. Limited by the calculating speed of computer, software can only correct the distortion of static images but not the distortion of dynamic images. To reach the real-time need, we design a distortion correction system based on FPGA. The method of hardware distortion correction is that the spatial correction data are calculated first under software circumstance, then converted into the address of hardware storage and stored in the hardware look-up table, through which data can be read out to correct gray level. The major benefit using FPGA is that the same circuit can be used for other circularly symmetric wide-angle lenses without being modified.
Dosimetry of 192Ir sources used for endovascular brachytherapy
NASA Astrophysics Data System (ADS)
Reynaert, N.; Van Eijkeren, M.; Taeymans, Y.; Thierens, H.
2001-02-01
An in-phantom calibration technique for 192Ir sources used for endovascular brachytherapy is presented. Three different source lengths were investigated. The calibration was performed in a solid phantom using a Farmer-type ionization chamber at source to detector distances ranging from 1 cm to 5 cm. The dosimetry protocol for medium-energy x-rays extended with a volume-averaging correction factor was used to convert the chamber reading to dose to water. The air kerma strength of the sources was determined as well. EGS4 Monte Carlo calculations were performed to determine the depth dose distribution at distances ranging from 0.6 mm to 10 cm from the source centre. In this way we were able to convert the absolute dose rate at 1 cm distance to the reference point chosen at 2 mm distance. The Monte Carlo results were confirmed by radiochromic film measurements, performed with a double-exposure technique. The dwell times to deliver a dose of 14 Gy at the reference point were determined and compared with results given by the source supplier (CORDIS). They determined the dwell times from a Sievert integration technique based on the source activity. The results from both methods agreed to within 2% for the 12 sources that were evaluated. A Visual Basic routine that superimposes dose distributions, based on the Monte Carlo calculations and the in-phantom calibration, onto intravascular ultrasound images is presented. This routine can be used as an online treatment planning program.
Learning Human Actions by Combining Global Dynamics and Local Appearance.
Luo, Guan; Yang, Shuang; Tian, Guodong; Yuan, Chunfeng; Hu, Weiming; Maybank, Stephen J
2014-12-01
In this paper, we address the problem of human action recognition through combining global temporal dynamics and local visual spatio-temporal appearance features. For this purpose, in the global temporal dimension, we propose to model the motion dynamics with robust linear dynamical systems (LDSs) and use the model parameters as motion descriptors. Since LDSs live in a non-Euclidean space and the descriptors are in non-vector form, we propose a shift invariant subspace angles based distance to measure the similarity between LDSs. In the local visual dimension, we construct curved spatio-temporal cuboids along the trajectories of densely sampled feature points and describe them using histograms of oriented gradients (HOG). The distance between motion sequences is computed with the Chi-Squared histogram distance in the bag-of-words framework. Finally we perform classification using the maximum margin distance learning method by combining the global dynamic distances and the local visual distances. We evaluate our approach for action recognition on five short clips data sets, namely Weizmann, KTH, UCF sports, Hollywood2 and UCF50, as well as three long continuous data sets, namely VIRAT, ADL and CRIM13. We show competitive results as compared with current state-of-the-art methods.
The visual perception of distance ratios outdoors.
Norman, J Farley; Adkins, Olivia C; Dowell, Catherine J; Shain, Lindsey M; Hoyng, Stevie C; Kinnard, Jonathan D
2017-05-01
We conducted an experiment to evaluate the ability of 32 younger and older adults to visually perceive distances in an outdoor setting. On any given trial, the observers viewed 2 environmental distances and were required to estimate the distance ratio-the length of the (usually) larger distance relative to that of the shorter. The stimulus distance ratios ranged from 1.0 (the stimulus distances were identical) to 8.0 (1 distance interval was 8.0 times longer than the other). The stimulus distances were presented within a 26 m × 60 m portion of a grassy field. The observers were able to reliably estimate the stimulus distance ratios: The overall Pearson r correlation coefficient relating the judged and actual distance ratios was 0.762. Fifty-eight percent of the variance in the observers' perceived distance ratios could thus be accounted for by variations in the actual stimulus ratios. About half of the observers significantly underestimated the distance ratios, while the judgments of the remainder were essentially accurate. Significant modulatory effects of sex and age occurred, such that the male observers' judgments were the most precise, while those of the older males were the most accurate.
Addressing Challenges in Web Accessibility for the Blind and Visually Impaired
ERIC Educational Resources Information Center
Guercio, Angela; Stirbens, Kathleen A.; Williams, Joseph; Haiber, Charles
2011-01-01
Searching for relevant information on the web is an important aspect of distance learning. This activity is a challenge for visually impaired distance learners. While sighted people have the ability to filter information in a fast and non sequential way, blind persons rely on tools that process the information in a sequential way. Learning is…
The Effects of Distance and Intervening Obstacles on Visual Inference in Blind and Sighted Children.
ERIC Educational Resources Information Center
Bigelow, Ann E.
1991-01-01
Blind and visually impaired children, and children with normal sight, were asked whether an observer could see a toy from varying distances under conditions in which obstacles did or did not intervene between the toy and the observer. Blind children took longer than other children to master the task. (BC)
Perceived distance depends on the orientation of both the body and the visual environment.
Harris, Laurence R; Mander, Charles
2014-10-15
Models of depth perception typically omit the orientation and height of the observer despite the potential usefulness of the height above the ground plane and the need to know about head position to interpret retinal disparity information. To assess the contribution of orientation to perceived distance, we used the York University Tumbled and Tumbling Room facilities to modulate both perceived and actual body orientation. These facilities are realistically decorated rooms that can be systematically arranged to vary the relative orientation of visual, gravity, and body cues to upright. To assess perceived depth we exploited size/distance constancy. Observers judged the perceived length of a visual line (controlled by a QUEST adaptive procedure) projected on to the wall of the facilities, relative to the length of an unseen iron rod held in their hands. In the Tumbled Room (viewing distance 337 cm) the line was set about 10% longer when participants were supine compared to when they were upright. In the Tumbling Room (viewing distance 114 cm), the line was set about 11% longer when participants were either supine or made to feel that they were supine by the orientation of the room. Matching a longer visual line to the reference rod is compatible with the opposite wall being perceived as closer. The effect was modulated by whether viewing was monocular or binocular at a viewing distance of 114 cm but not at 337 cm suggesting that reliable binocular cues can override the effect. © 2014 ARVO.
Sajjadi, Valleh; Ghoreishi, Mohammad; Jafarzadehpour, Ebrahim
2015-01-01
To compare the refractive and visual outcomes and higher order aberrations in patients with low to moderate myopia who underwent customized photorefractive keratectomy (PRK) or femtosecond laser in situ keratomileusis (Femto-LASIK) this research performed. This study includes data of 120 consecutive eyes of 60 patients with myopia between -3.00 D and -7.00 D with or without astigmatism in two surgery groups: PRK and Femto-LASIK. Refractive, visual, and aberration outcomes of the two methods of surgery were compared after 6 months of follow-up. After six months of follow-up, sphere and cylinder were found significantly decreased and there was no statistically significant difference between the two groups. The mean of uncorrected distance visual acuity in LogMar format for the PRK and Femto-LASIK groups was -0.03±0.07 and -0.01±0.08, respectively, which was not significantly different between the two groups. Higher orders and spherical aberrations increased in both groups significantly, while total aberrations decreased in both groups. After surgery, no differences were observed between the two groups in the amount of aberrations. In conclusion, Both PRK and Femto-LASIK are effective and safe in correcting myopia. In this study PRK induced more spherical and higher order aberrations than Femto-LASIK. PMID:27800501
Bilateral posterior crystalline lens dislocations in an otherwise healthy child.
AlShehri, Omar A; Almarzouki, Hashem; Alharbi, Badr A; Alqahtani, Mohammed; Allam, Khaled
2017-01-01
Introduction: Ectopia lentis is defined as a crystalline lens displacement, either partially or completely, due to zonular abnormalities. It can be a result of trauma, hereditary ocular disease, or part of systemic diseases, like Marfan syndrome and homocystinuria. Case description: We report a case of a medically free 16-year-old girl, who was referred to our hospital complaining of poor vision and a squint in both eyes since childhood. Her history included a traffic accident when she was one-year-old. She was previously diagnosed with alternating esotropia, which was treated with glasses, alternating patching, and bilateral Botox injections. On examination, she had a visual acuity of 6/7.5 with correction in the right eye and 6/6 with correction in the left eye. She had an esotropia of 60 prism diopters, which was partially corrected to 40 prism diopters for near and distance vision. Fundus examination showed myopic changes in each eye and dislocated lenses in the posterior pole at 6 o'clock. Our case was stable, so we used conservative management with contact lenses. Conclusion: Bilateral posterior lens dislocation is very rare. A proper examination is important and early diagnosis can prevent serious complications, such as retinal detachment or pupillary block glaucoma.
Lu, Qing; Zheng, Yuanyuan; Sun, Baochen; Cui, Tongtong; Congdon, Nathan; Hu, Ailian; Chen, Jianhua; Shi, Jiliang
2009-06-01
To evaluate the prevalence and causes of visual impairment among Chinese children aged 3 to 6 years in Beijing. Population-based prevalence survey. Presenting and pinhole visual acuity were tested using picture optotypes or, in children with pinhole vision < 6/18, a Snellen tumbling E chart. Comprehensive eye examinations and cycloplegic refraction were carried out for children with pinhole vision < 6/18 in the better-seeing eye. All examinations were completed on 17,699 children aged 3 to 6 years (95.3% of sample). Subjects with bilateral correctable low vision (presenting vision < 6/18 correctable to >or= 6/18) numbered 57 (0.322%; 95% confidence interval [CI], 0.237% to 0.403%), while 14 (0.079%; 95% CI, 0.038% to 0.120%) had bilateral uncorrectable low vision (best-corrected vision of < 6/18 and >or= 3/60), and 5 subjects (0.028%; 95% CI, 0.004% to 0.054%) were bilaterally blind (best-corrected acuity < 3/60). The etiology of 76 cases of visual impairment included: refractive error in 57 children (75%), hereditary factors (microphthalmos, congenital cataract, congenital motor nystagmus, albinism, and optic nerve disease) in 13 children (17.1 %), amblyopia in 3 children (3.95%), and cortical blindness in 1 child (1.3%). The cause of visual impairment could not be established in 2 (2.63%) children. The prevalence of visual impairment did not differ by gender, but correctable low vision was significantly (P < .0001) more common among urban as compared with rural children. The leading causes of visual impairment among Chinese preschool-aged children are refractive error and hereditary eye diseases. A higher prevalence of refractive error is already present among urban as compared with rural children in this preschool population.
Pretorius, P. Hendrik; Johnson, Karen L.; King, Michael A.
2016-01-01
We have recently been successful in the development and testing of rigid-body motion tracking, estimation and compensation for cardiac perfusion SPECT based on a visual tracking system (VTS). The goal of this study was to evaluate in patients the effectiveness of our rigid-body motion compensation strategy. Sixty-four patient volunteers were asked to remain motionless or execute some predefined body motion during an additional second stress perfusion acquisition. Acquisitions were performed using the standard clinical protocol with 64 projections acquired through 180 degrees. All data were reconstructed with an ordered-subsets expectation-maximization (OSEM) algorithm using 4 projections per subset and 5 iterations. All physical degradation factors were addressed (attenuation, scatter, and distance dependent resolution), while a 3-dimensional Gaussian rotator was used during reconstruction to correct for six-degree-of-freedom (6-DOF) rigid-body motion estimated by the VTS. Polar map quantification was employed to evaluate compensation techniques. In 54.7% of the uncorrected second stress studies there was a statistically significant difference in the polar maps, and in 45.3% this made a difference in the interpretation of segmental perfusion. Motion correction reduced the impact of motion such that with it 32.8 % of the polar maps were statistically significantly different, and in 14.1% this difference changed the interpretation of segmental perfusion. The improvement shown in polar map quantitation translated to visually improved uniformity of the SPECT slices. PMID:28042170
Visual Outcomes of Parapapillary Uveal Melanomas Following Proton Beam Therapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thariat, Juliette, E-mail: jthariat@gmail.com; Grange, Jean-Daniel; Mosci, Carlo
Purpose: In parapapillary melanoma patients, radiation-induced optic complications are frequent and visual acuity is often compromised. We investigated dose-effect relationships for the optic nerve with respect to visual acuity after proton therapy. Methods and Materials: Of 5205 patients treated between 1991 and 2014, those treated using computed tomography (CT)-based planning to 52 Gy (prescribed dose, not accounting for relative biologic effectiveness correction of 1.1) in 4 fractions, with minimal 6-month follow-up and documented initial and last visual acuity, were included. Deterioration of ≥0.3 logMAR between initial and last visual acuity results was reported. Results: A total of 865 consecutive patients weremore » included. Median follow-up was 69 months, mean age was 61.7 years, tumor abutted the papilla in 35.1% of patients, and tumor-to-fovea distance was ≤3 mm in 74.2% of patients. Five-year relapse-free survival rate was 92.7%. Visual acuity was ≥20/200 in 72.6% of patients initially and 47.2% at last follow-up. A wedge filter was used in 47.8% of the patients, with a positive impact on vision and no impact on relapse. Glaucoma, radiation-induced optic neuropathy, maculopathy were reported in 17.9%, 47.5%, and 33.6% of patients, respectively. On multivariate analysis, age, diabetes, thickness, initial visual acuity and percentage of macula receiving 26 Gy were predictive of visual acuity. Furthermore, patients irradiated to ≥80% of their papilla had better visual acuity when limiting the 50% (30-Gy) and 20% (12-Gy) isodoses to ≤2 mm and 6 mm of optic nerve length, respectively. Conclusions: A personalized proton therapy plan with optic nerve and macular sparing can be used efficiently with good oncological and functional results in parapapillary melanoma patients.« less
ERIC Educational Resources Information Center
GROVER, EDWARD C.; AND OTHERS
THIS STUDY INVESTIGATED THE DECLINING ENROLLMENT IN OHIO'S PROGRAMS FOR PARTIALLY SEEING CHILDREN AND THE PROBLEMS OF INCIDENCE, VISUAL FUNCTIONING, AND MULTIPLE HANDICAPS. PARTIALLY SEEING CHILDREN IDENTIFIED BY THE STUDY HAD A VISUAL ACUITY AFTER CORRECTION OF 20/70 OR LESS AND/OR CORRECTION OF MORE THAN 10 DIOPTERS OF MYOPIA. THE SCHOOL NURSES…
Modified iPad for treatment of amblyopia: a preliminary study.
Handa, Tomoya; Ishikawa, Hitoshi; Shoji, Nobuyuki; Ikeda, Tetsuya; Totuka, Satoru; Goseki, Toshiaki; Shimizu, Kimiya
2015-12-01
We report the results of a new amblyopia treatment device used in 7 children with anisometropic amblyopia. The Occlu-pad was created by removing the polarizing film layer from the liquid crystal display screen of an iPad Air (Apple Inc, Cupertino, CA). Patients were asked to wear special glasses that contained a polarizing filter for their amblyopic eye and a light reduction filter for their normal eye and instructed to play an amblyopia training game displayed only to the amblyopic eye. In 5 patients corrected distance visual acuities in the amblyopic eyes improved after 2 months' treatment on average by 0.38 (logarithm of the minimum angle of resolution). Copyright © 2015 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.
High-speed switchable lens enables the development of a volumetric stereoscopic display
Love, Gordon D.; Hoffman, David M.; Hands, Philip J.W.; Gao, James; Kirby, Andrew K.; Banks, Martin S.
2011-01-01
Stereoscopic displays present different images to the two eyes and thereby create a compelling three-dimensional (3D) sensation. They are being developed for numerous applications including cinema, television, virtual prototyping, and medical imaging. However, stereoscopic displays cause perceptual distortions, performance decrements, and visual fatigue. These problems occur because some of the presented depth cues (i.e., perspective and binocular disparity) specify the intended 3D scene while focus cues (blur and accommodation) specify the fixed distance of the display itself. We have developed a stereoscopic display that circumvents these problems. It consists of a fast switchable lens synchronized to the display such that focus cues are nearly correct. The system has great potential for both basic vision research and display applications. PMID:19724571
ERIC Educational Resources Information Center
Amit, Elinor; Mehoudar, Eyal; Trope, Yaacov; Yovel, Galit
2012-01-01
It is well established that scenes and objects elicit a highly selective response in specific brain regions in the ventral visual cortex. An inherent difference between these categories that has not been explored yet is their perceived distance from the observer (i.e. scenes are distal whereas objects are proximal). The current study aimed to test…
The effect of saccade metrics on the corollary discharge contribution to perceived eye location
Bansal, Sonia; Jayet Bray, Laurence C.; Peterson, Matthew S.
2015-01-01
Corollary discharge (CD) is hypothesized to provide the movement information (direction and amplitude) required to compensate for the saccade-induced disruptions to visual input. Here, we investigated to what extent these conveyed metrics influence perceptual stability in human subjects with a target-displacement detection task. Subjects made saccades to targets located at different amplitudes (4°, 6°, or 8°) and directions (horizontal or vertical). During the saccade, the target disappeared and then reappeared at a shifted location either in the same direction or opposite to the movement vector. Subjects reported the target displacement direction, and from these reports we determined the perceptual threshold for shift detection and estimate of target location. Our results indicate that the thresholds for all amplitudes and directions generally scaled with saccade amplitude. Additionally, subjects on average produced hypometric saccades with an estimated CD gain <1. Finally, we examined the contribution of different error signals to perceptual performance, the saccade error (movement-to-movement variability in saccade amplitude) and visual error (distance between the fovea and the shifted target location). Perceptual judgment was not influenced by the fluctuations in movement amplitude, and performance was largely the same across movement directions for different magnitudes of visual error. Importantly, subjects reported the correct direction of target displacement above chance level for very small visual errors (<0.75°), even when these errors were opposite the target-shift direction. Collectively, these results suggest that the CD-based compensatory mechanisms for visual disruptions are highly accurate and comparable for saccades with different metrics. PMID:25761955
How Ants Use Vision When Homing Backward.
Schwarz, Sebastian; Mangan, Michael; Zeil, Jochen; Webb, Barbara; Wystrach, Antoine
2017-02-06
Ants can navigate over long distances between their nest and food sites using visual cues [1, 2]. Recent studies show that this capacity is undiminished when walking backward while dragging a heavy food item [3-5]. This challenges the idea that ants use egocentric visual memories of the scene for guidance [1, 2, 6]. Can ants use their visual memories of the terrestrial cues when going backward? Our results suggest that ants do not adjust their direction of travel based on the perceived scene while going backward. Instead, they maintain a straight direction using their celestial compass. This direction can be dictated by their path integrator [5] but can also be set using terrestrial visual cues after a forward peek. If the food item is too heavy to enable body rotations, ants moving backward drop their food on occasion, rotate and walk a few steps forward, return to the food, and drag it backward in a now-corrected direction defined by terrestrial cues. Furthermore, we show that ants can maintain their direction of travel independently of their body orientation. It thus appears that egocentric retinal alignment is required for visual scene recognition, but ants can translate this acquired directional information into a holonomic frame of reference, which enables them to decouple their travel direction from their body orientation and hence navigate backward. This reveals substantial flexibility and communication between different types of navigational information: from terrestrial to celestial cues and from egocentric to holonomic directional memories. VIDEO ABSTRACT. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Bayraktar Bilen, Neslihan; Hepsen, Ibrahim F.; Arce, Carlos G.
2016-01-01
AIM To analyze the relationship between two visual functions and refractive, topographic, pachymetric and aberrometric indicators in eyes with keratoconus. METHODS Corrected distance visual acuity (CDVA), and letter contrast sensitivity (CS) were correlated with refraction, corneal topography, pachymetry, and total corneal wavefront data prospectively in 71 eyes with keratoconus. The topographic indices assessed were simulated keratometry for the flattest and steepest meridians (SimK1 and SimK2), posterior steeper K (Ks), elevation value in best-fit sphere (BFS) maps, squared eccentricity (Є2), aspheric asymmetric index (AAI), pachymetry, thickness progression index (TPI), the amount of pachymetric decentralization (APD), and GalileiTM-keratoconus indices. RESULTS The mean CDVA (expressed as logMAR) were 0.25±0.21. The mean CS was 1.25±0.46. The spherical refraction correlated well with CDVA (r=-0.526, P<0.001). From topographic indices, SRI correlated with CS (r=-0.695), and IAI with CS (r=-0.672) (P<0.001 for all). Root mean square (RMS) was 4.3±1.81 µm, spherical aberration (SA) was -0.4±0.67 µm, vertical and horizontal coma were -2.1±1.47 and -0.4±0.72 µm. All wavefront data (except horizontal coma), AAI, Є2 and maximum BFS correlated significantly with the visual function (P≤0.001 for all). CONCLUSION In this study, CS is more affected than CDVA as a visual function. The quantity and quality of vision is significantly correlated with well-known and new topographic indices. There is not a significant correlation between visual function and pachymetric parameters. The significantly correlated indices can be used in staging keratoconus and to follow the outcome of a treatment. PMID:27588266
Ma, Yingyan; Qu, Xiaomei; Zhu, Xiaofeng; Xu, Xun; Zhu, Jianfeng; Sankaridurg, Padmaja; Lin, Senlin; Lu, Lina; Zhao, Rong; Wang, Ling; Shi, Huijing; Tan, Hui; You, Xiaofang; Yuan, Hong; Sun, Sifei; Wang, Mingjin; He, Xiangui; Zou, Haidong; Congdon, Nathan
2016-11-01
We assessed changes in age-specific prevalence of refractive error at the time of starting school, by comparing preschool and school age cohorts in Shanghai, China. A cross-sectional study was done in Jiading District, Shanghai during November and December 2013. We randomly selected 7 kindergartens and 7 primary schools, with probability proportionate to size. Chinese children (n = 8398) aged 3 to 10 years were enumerated, and 8267 (98.4%) were included. Children underwent distance visual acuity assessment and refraction measurement by cycloplegic autorefraction and subjective refraction. The prevalence of uncorrected visual acuity (UCVA), presenting visual acuity, and best-corrected visual acuity in the better eye of ≤20/40 was 19.8%, 15.5%, and 1.7%, respectively. Among those with UCVA ≤ 20/40, 93.2% could achieve visual acuity of ≥20/32 with refraction. Only 28.7% (n = 465) of children with UCVA in the better eye of ≤20/40 wore glasses. Prevalence of myopia (spherical equivalent ≤-0.5 diopters [D] in at least one eye) increased from 1.78% in 3-year-olds to 52.2% in 10-year-olds, while prevalence of hyperopia (spherical equivalent ≥+2.0 D) decreased from 17.8% among 3-year-olds to 2.6% by 10 years of age. After adjusting for age, attending elite "high-level" school was statistically associated with greater myopia prevalence. The prevalence of myopia was lower or comparable to that reported in other populations from age 3 to 5 years, but increased dramatically after 6 years, consistent with a strong environmental role of schooling on myopia development.
Lundström, Mats; Dickman, Mor; Henry, Ype; Manning, Sonia; Rosen, Paul; Tassignon, Marie-José; Young, David; Stenevi, Ulf
2017-12-01
To describe a large cohort of femtosecond laser-assisted cataract surgeries in terms of baseline characteristics and the related outcomes. Eighteen cataract surgery clinics in 9 European countries and Australia. Prospective multicenter case series. Data on consecutive eyes having femtosecond laser-assisted cataract surgery in the participating clinics were entered in the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO). A trained registry manager in each clinic was responsible for valid reporting to the EUREQUO. Demographics, preoperative corrected distance visual acuity (CDVA), risk factors, type of surgery, type of intraocular lens, visual outcomes, refractive outcomes, and complications were reported. Complete data were available for 3379 cases. The mean age was 64.4 years ± 10.9 (SD) and 57.8% (95% confidence interval [CI], 56.1-59.5) of the patients were women. A surgical complication was reported in 2.9% of all cases (95% CI, 2.4-3.5). The mean postoperative CDVA was 0.04 ± 0.15. logarithm of the minimum angle of resolution. A biometry prediction error (spherical equivalent) was within ±0.5 diopter in 71.8% (95% CI, 70.3-73.3) of all surgeries. Postoperative complications were reported in 3.3% (95% CI, 2.7-4.0). Patients with good preoperative CDVA had the best visual and refractive outcomes; patients with poor preoperative visual acuity had poorer outcomes. The visual and refractive outcomes of femtosecond laser-assisted cataract surgery were favorable compared with manual phacoemulsification. The outcomes were highly influenced by the preoperative visual acuity, but all preoperative CDVA groups had acceptable outcomes. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Yamauchi, Tomofusa; Tabuchi, Hitoshi; Takase, Kosuke; Ohsugi, Hideharu; Ohara, Zaigen; Kiuchi, Yoshiaki
2013-01-01
Purpose To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. Methods The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patients who were implanted with Tecnis® multifocal IOLs bilaterally. The monofocal group was an age- and sex-matched control group, and included 85 patients who were implanted with Tecnis® monofocal IOLs bilaterally. Lens opacity grading, the radius of corneal curvature, corneal astigmatism, axial length and the refractive status were measured preoperatively. Pupil size, ocular aberrometry, distance, intermediate and near visual acuity, contrast sensitivity with and without glare and the responses to a quality-of-vision questionnaire were evaluated pre- and postoperatively. Results The uncorrected near visual acuity was significantly better in the multifocal group, whereas both the corrected intermediate and near visual acuity were better in the monofocal group. Contrast sensitivity (with and without glare) was significantly better in the monofocal group. The rate of spectacle dependency was significantly lower in the multifocal group. There were no significant differences between the two groups regarding most items of the postoperative quality-of-vision questionnaire (VFQ-25), with the exception that the patients in the monofocal group reported fewer problems with nighttime driving. Conclusions The multifocal IOLs used in this study reduced spectacle dependency more so than monofocal IOLs and did not compromise the subjective visual function, with the exception of nighttime driving. PMID:23840836
Low-level laser therapy improves visual acuity in adolescent and adult patients with amblyopia.
Ivandic, Boris T; Ivandic, Tomislav
2012-03-01
The purpose of this study was to examine the effects of low-level laser therapy (LLLT) on visual acuity in adolescent and adult patients with amblyopia. Currently, amblyopia can be treated successfully only in children. In this single-blinded, placebo-controlled study, 178 patients (mean age 46.8 years) with amblyopia caused by ametropia (110 eyes) or strabismus (121 eyes) were included. For LLLT, the area of the macula was irradiated through the conjunctiva from 1 cm distance for 30 sec with laser light (780 nm, 292 Hz, 1:1 duty cycle; average power 7.5 mW; spot area 3 mm(2)). The treatment was repeated on average 3.5 times, resulting in a mean total dose of 0.77 J/cm(2). No occlusion was applied, and no additional medication was administered. Best corrected distant visual acuity was determined using Snellen projection optotypes. In 12 patients (12 eyes), the multifocal visual evoked potential (M-VEP) was recorded. A control group of 20 patients (20 eyes) received mock treatment. Visual acuity improved in ∼90% of the eyes treated with LLLT (p<0.001), increasing by three or more lines in 56.2% and 53.6% of the eyes with amblyopia caused by ametropia and strabismus, respectively. The treatment effect was maintained for at least 6 months. The mean M-VEP amplitude increased by 1207 nV (p<0.001) and mean latency was reduced by 7 msec (p=0.14). No changes were noted in the control group. LLLT led to a significant improvement in visual acuity in adolescent and adult patients with amblyopia caused by ametropia or strabismus.
Ghosh, Payel; Chandler, Adam G; Altinmakas, Emre; Rong, John; Ng, Chaan S
2016-01-01
The aim of this study was to investigate the feasibility of shuttle-mode computed tomography (CT) technology for body perfusion applications by quantitatively assessing and correcting motion artifacts. Noncontrast shuttle-mode CT scans (10 phases, 2 nonoverlapping bed locations) were acquired from 4 patients on a GE 750HD CT scanner. Shuttling effects were quantified using Euclidean distances (between-phase and between-bed locations) of corresponding fiducial points on the shuttle and reference phase scans (prior to shuttle mode). Motion correction with nonrigid registration was evaluated using sum-of-squares differences and distances between centers of segmented volumes of interest on shuttle and references images. Fiducial point analysis showed an average shuttling motion of 0.85 ± 1.05 mm (between-bed) and 1.18 ± 1.46 mm (between-phase), respectively. The volume-of-interest analysis of the nonrigid registration results showed improved sum-of-squares differences from 2950 to 597, between-bed distance from 1.64 to 1.20 mm, and between-phase distance from 2.64 to 1.33 mm, respectively, averaged over all cases. Shuttling effects introduced during shuttle-mode CT acquisitions can be computationally corrected for body perfusion applications.
Clark, R. C.; Brebner, J. S.
2017-01-01
Researchers must assess similarities and differences in colour from an animal's eye view when investigating hypotheses in ecology, evolution and behaviour. Nervous systems generate colour perceptions by comparing the responses of different spectral classes of photoreceptor through colour opponent mechanisms, and the performance of these mechanisms is limited by photoreceptor noise. Accordingly, the receptor noise limited (RNL) colour distance model of Vorobyev and Osorio (Vorobyev & Osorio 1998 Proc. R. Soc. Lond. B 265, 351–358 (doi:10.1098/rspb.1998.0302)) generates predictions about the discriminability of colours that agree with behavioural data, and consequently it has found wide application in studies of animal colour vision. Vorobyev and Osorio (1998) provide equations to calculate RNL colour distances for animals with di-, tri- and tetrachromatic vision, which is adequate for many species. However, researchers may sometimes wish to compute RNL colour distances for potentially more complex colour visual systems. Thus, we derive a simple, single formula for the computation of RNL distance between two measurements of colour, equivalent to the published di-, tri- and tetrachromatic equations of Vorobyev and Osorio (1998), and valid for colour visual systems with any number of types of noisy photoreceptors. This formula will allow the easy application of this important colour visual model across the fields of ecology, evolution and behaviour. PMID:28989773
Subconscious Visual Cues during Movement Execution Allow Correct Online Choice Reactions
Leukel, Christian; Lundbye-Jensen, Jesper; Christensen, Mark Schram; Gollhofer, Albert; Nielsen, Jens Bo; Taube, Wolfgang
2012-01-01
Part of the sensory information is processed by our central nervous system without conscious perception. Subconscious processing has been shown to be capable of triggering motor reactions. In the present study, we asked the question whether visual information, which is not consciously perceived, could influence decision-making in a choice reaction task. Ten healthy subjects (28±5 years) executed two different experimental protocols. In the Motor reaction protocol, a visual target cue was shown on a computer screen. Depending on the displayed cue, subjects had to either complete a reaching movement (go-condition) or had to abort the movement (stop-condition). The cue was presented with different display durations (20–160 ms). In the second Verbalization protocol, subjects verbalized what they experienced on the screen. Again, the cue was presented with different display durations. This second protocol tested for conscious perception of the visual cue. The results of this study show that subjects achieved significantly more correct responses in the Motor reaction protocol than in the Verbalization protocol. This difference was only observed at the very short display durations of the visual cue. Since correct responses in the Verbalization protocol required conscious perception of the visual information, our findings imply that the subjects performed correct motor responses to visual cues, which they were not conscious about. It is therefore concluded that humans may reach decisions based on subconscious visual information in a choice reaction task. PMID:23049749
Guo, Cindy X; Babu, Raiju J; Black, Joanna M; Bobier, William R; Lam, Carly S Y; Dai, Shuan; Gao, Tina Y; Hess, Robert F; Jenkins, Michelle; Jiang, Yannan; Kowal, Lionel; Parag, Varsha; South, Jayshree; Staffieri, Sandra Elfride; Walker, Natalie; Wadham, Angela; Thompson, Benjamin
2016-10-18
Amblyopia is a common neurodevelopmental disorder of vision that is characterised by visual impairment in one eye and compromised binocular visual function. Existing evidence-based treatments for children include patching the nonamblyopic eye to encourage use of the amblyopic eye. Currently there are no widely accepted treatments available for adults with amblyopia. The aim of this trial is to assess the efficacy of a new binocular, videogame-based treatment for amblyopia in older children and adults. We hypothesise that binocular treatment will significantly improve amblyopic eye visual acuity relative to placebo treatment. The BRAVO study is a double-blind, randomised, placebo-controlled multicentre trial to assess the effectiveness of a novel videogame-based binocular treatment for amblyopia. One hundred and eight participants aged 7 years or older with anisometropic and/or strabismic amblyopia (defined as ≥0.2 LogMAR interocular visual acuity difference, ≥0.3 LogMAR amblyopic eye visual acuity and no ocular disease) will be recruited via ophthalmologists, optometrists, clinical record searches and public advertisements at five sites in New Zealand, Canada, Hong Kong and Australia. Eligible participants will be randomised by computer in a 1:1 ratio, with stratification by age group: 7-12, 13-17 and 18 years and older. Participants will be randomised to receive 6 weeks of active or placebo home-based binocular treatment. Treatment will be in the form of a modified interactive falling-blocks game, implemented on a 5th generation iPod touch device viewed through red/green anaglyphic glasses. Participants and those assessing outcomes will be blinded to group assignment. The primary outcome is the change in best-corrected distance visual acuity in the amblyopic eye from baseline to 6 weeks post randomisation. Secondary outcomes include distance and near visual acuity, stereopsis, interocular suppression, angle of strabismus (where applicable) measured at baseline, 3, 6, 12 and 24 weeks post randomisation. Treatment compliance and acceptability will also be assessed along with quality of life for adult participants. The BRAVO study is the first randomised controlled trial of a home-based videogame treatment for older children and adults with amblyopia. The results will indicate whether a binocular approach to amblyopia treatment conducted at home is effective for patients aged 7 years or older. This trial was registered in Australia and New Zealand Clinical Trials Registry ( ACTRN12613001004752 ) on 10 September 2013.
A tiger beetle’s pursuit of prey depends on distance
NASA Astrophysics Data System (ADS)
Noest, R. M.; Wang, Z. Jane
2017-04-01
Tiger beetles pursue prey by adjusting their heading according to a time-delayed proportional control law that minimizes the error angle (Haselsteiner et al 2014 J. R. Soc. Interface 11 20140216). This control law can be further interpreted in terms of mechanical actuation: to catch prey, tiger beetles exert a sideways force by biasing their tripod gait in proportion to the error angle measured half a stride earlier. The proportional gain was found to be nearly optimal in the sense that it minimizes the time to point directly toward the prey. For a time-delayed linear proportional controller, the optimal gain, k, is inversely proportional to the time delay, τ, and satisfies kτ =1/e . Here we present evidence that tiger beetles adjust their control gain during their pursuit of prey. Our analysis shows two critical distances: one corresponding to the beetle’s final approach to the prey, and the second, less expected, occurring at a distance around 10 cm for a prey size of 4.5 mm. The beetle initiates its chase using a sub-critical gain and increases the gain to the optimal value once the prey is within this critical distance. Insects use a variety of methods to detect distance, often involving different visual cues. Here we examine two such methods: one based on motion parallax and the other based on the prey’s elevation angle. We show that, in order for the motion parallax method to explain the observed data, the beetle needs to correct for the ratio of the prey’s sideways velocity relative to its own. On the other hand, the simpler method based on the elevation angle can detect both the distance and the prey’s size. Moreover we find that the transition distance corresponds to the accuracy required to distinguish small prey from large predators.
Fine lattice lines on the corneal surface after laser in situ keratomileusis (LASIK).
Carpel, E F; Carlson, K H; Shannon, S
2000-03-01
To present an example of a pattern of lines resembling fine lattice on the corneal surface subsequent to laser in situ keratomileusis (LASIK). This subtle phenomenon may be relatively common and may affect visual outcome. Case report. A 41-year-old year old man with high myopia and best-corrected visual acuity of 20/20 +2 in each eye underwent laser in situ keratomileusis (LASIK). No operative or postoperative complications occurred. No striae were evident on slit-lamp examination with direct illumination and retroillumination at the time of surgery or in the postoperative period. Postoperative uncorrected visual acuity was 20/25 with a best-corrected spectacle correction of 20/25 in both eyes. Fine lines in a lattice pattern were seen only with fluorescein dye in the precorneal tear film as areas of "negative stain" within the LASIK flap. With tear film supplementation, the lines were less evident and visual acuity improved. One year postoperatively, his uncorrected visual acuity was 20/25 in both eyes. The best-corrected spectacle visual acuity was RE: 20/20 -2, LE: 20/25. The fine lines were still present within the flap. A soft contact lens improved visual acuity to 20/20 in both eyes. Although all four puncta were occluded, he had no epiphora. Fine lines in a lattice pattern that may represent folds in the epithelium or Bowman layer may be present within the flap after LASIK and may adversely affect visual acuity. They may be visible as areas of negative stain with fluorescein dye in the precorneal tear film in the absence of any striae visible in the flap. These superficial lines have been seen more in patients with high degrees of correction and in patients with dry eye. If visual acuity is affected, it may be improved with punctal occlusion, tear supplements, or a contact lens.
Stereoacuity changes after laser in situ keratomileusis.
Singh, Digvijay; Saxena, Rohit; Sinha, Rajesh; Titiyal, Jeewan S
2015-02-01
To study changes in near and distance stereoacuity after laser in situ keratomileusis (LASIK). A prospective interventional study was conducted at an apex tertiary care ophthalmology center in India. Near and distance stereoacuity was tested in 40 patients (80 eyes) who underwent LASIK for myopic correction and got unaided vision of 0.67 or better in each eye. Stereoacuity was tested with best spectacle correction before LASIK, and post-LASIK stereoacuity was tested with unaided eye near and distance Randot tests. Forty patients (80 eyes) had a mean (±SD) pre-LASIK refractive error of -4.70 (±1.72) DS OD and -4.59 (±1.58) DS OS and a mean (±SD) anisometropia of 0.55 (±0.51) DS. The median pre-LASIK near stereoacuity was 70 arcsec and distance stereoacuity was 200 arcsec, both of which improved after LASIK to 30 and 60 arcsec, respectively (p < 0.001, both). Amount of refractive error was not associated with stereoacuity but anisometropia of greater than or equal to 1 diopter had significantly worse distance stereoacuity in both the pre-LASIK and post-LASIK period. The post-LASIK near stereoacuity and distance stereoacuity were strongly associated (r = 0.706, p < 0.001) unlike the change in stereoacuity. Near and distance stereoacuity shows significant improvement after LASIK. Stereoacuity is associated with the degree of anisometropia but not the amount of refractive error corrected.
Are children with low vision adapted to the visual environment in classrooms of mainstream schools?
Negiloni, Kalpa; Ramani, Krishna Kumar; Jeevitha, R; Kalva, Jayashree; Sudhir, Rachapalle Reddi
2018-02-01
The study aimed to evaluate the classroom environment of children with low vision and provide recommendations to reduce visual stress, with focus on mainstream schooling. The medical records of 110 children (5-17 years) seen in low vision clinic during 1 year period (2015) at a tertiary care center in south India were extracted. The visual function levels of children were compared to the details of their classroom environment. The study evaluated and recommended the chalkboard visual task size and viewing distance required for children with mild, moderate, and severe visual impairment (VI). The major causes of low vision based on the site of abnormality and etiology were retinal (80%) and hereditary (67%) conditions, respectively, in children with mild (n = 18), moderate (n = 72), and severe (n = 20) VI. Many of the children (72%) had difficulty in viewing chalkboard and common strategies used for better visibility included copying from friends (47%) and going closer to chalkboard (42%). To view the chalkboard with reduced visual stress, a child with mild VI can be seated at a maximum distance of 4.3 m from the chalkboard, with the minimum size of visual task (height of lowercase letter writing on chalkboard) recommended to be 3 cm. For 3/60-6/60 range, the maximum viewing distance with the visual task size of 4 cm is recommended to be 85 cm to 1.7 m. Simple modifications of the visual task size and seating arrangements can aid children with low vision with better visibility of chalkboard and reduced visual stress to manage in mainstream schools.
Kook, D; Bühren, J; Klaproth, O K; Bauch, A S; Derhartunian, V; Kohnen, T
2011-02-01
The purpose of this study was to evaluate a novel technique for the correction of postoperative astigmatism after penetrating keratoplasty with the use of the femtosecond laser creating astigmatic keratotomies (femto-AK) in the scope of a retrospective case series. Clinical data of ten eyes of nine patients with high residual astigmatism after penetrating keratoplasty undergoing paired femto-AK using a 60-kHz femtosecond laser (IntraLase™, AMO) were analyzed. A new software algorithm was used to create paired arcuate cuts deep into the donor corneal button with different cut angles. Target values were refraction, uncorrected visual acuity, best corrected visual acuity, topographic data (Orbscan®, Bausch & Lomb, Rochester, NY, USA), and corneal wavefront analysis using Visual Optics Lab (VOL)-Pro 7.14 Software (Sarver and Associates). Vector analysis was performed using the Holladay, Cravy and Koch formula. Statistical analysis was performed to detect significances between visits using Student's t test. All procedures were performed without any major complications. The mean follow-up was 13 months. The mean patient age was 48.7 years. The preoperative mean uncorrected visual acuity (logMAR) was 1.27, best corrected visual acuity 0.55, mean subjective cylinder -7.4 D, and mean topometric astigmatism 9.3 D. The postoperative mean uncorrected visual acuity (logMAR) was 1.12, best corrected visual acuity 0.47, mean subjective cylinder -4.1 D, and mean topometric astigmatism 6.5 D. Differences between corneal higher order aberrations showed a high standard deviation and were therefore not statistically significant. Astigmatic keratotomy using the femtosecond laser seems to be a safe and effective tool for the correction of higher corneal astigmatisms. Due to the biomechanical properties of the cornea and missing empirical data for the novel femto-AK technology, higher numbers of patients are necessary to develop optimal treatment nomograms.
On the weight of indels in genomic distances
2011-01-01
Background Classical approaches to compute the genomic distance are usually limited to genomes with the same content, without duplicated markers. However, differences in the gene content are frequently observed and can reflect important evolutionary aspects. A few polynomial time algorithms that include genome rearrangements, insertions and deletions (or substitutions) were already proposed. These methods often allow a block of contiguous markers to be inserted, deleted or substituted at once but result in distance functions that do not respect the triangular inequality and hence do not constitute metrics. Results In the present study we discuss the disruption of the triangular inequality in some of the available methods and give a framework to establish an efficient correction for two models recently proposed, one that includes insertions, deletions and double cut and join (DCJ) operations, and one that includes substitutions and DCJ operations. Conclusions We show that the proposed framework establishes the triangular inequality in both distances, by summing a surcharge on indel operations and on substitutions that depends only on the number of markers affected by these operations. This correction can be applied a posteriori, without interfering with the already available formulas to compute these distances. We claim that this correction leads to distances that are biologically more plausible. PMID:22151784
Driving time modulates accommodative response and intraocular pressure.
Vera, Jesús; Diaz-Piedra, Carolina; Jiménez, Raimundo; Morales, José M; Catena, Andrés; Cardenas, David; Di Stasi, Leandro L
2016-10-01
Driving is a task mainly reliant on the visual system. Most of the time, while driving, our eyes are constantly focusing and refocusing between the road and the dashboard or near and far traffic. Thus, prolonged driving time should produce visual fatigue. Here, for the first time, we investigated the effects of driving time, a common inducer of driver fatigue, on two ocular parameters: the accommodative response (AR) and the intraocular pressure (IOP). A pre/post-test design has been used to assess the impact of driving time on both indices. Twelve participants (out of 17 recruited) completed the study (5 women, 24.42±2.84years old). The participants were healthy and active drivers with no visual impairment or pathology. They drove for 2h in a virtual driving environment. We assessed AR and IOP before and after the driving session, and also collected subjective measures of arousal and fatigue. We found that IOP and AR decreased (i.e., the accommodative lag increased) after the driving session (p=0.03 and p<0.001, respectively). Moreover, the nearest distances tested (20cm, 25cm, and 33cm) induced the highest decreases in AR (corrected p-values<0.05). Consistent with these findings, the subjective levels of arousal decreased and levels of fatigue increased after the driving session (all p-values<0.001). These results represent an innovative step towards an objective, valid, and reliable assessment of fatigue-impaired driving based on visual fatigue signs. Copyright © 2016 Elsevier Inc. All rights reserved.
Reinforcing Visual Grouping Cues to Communicate Complex Informational Structure.
Bae, Juhee; Watson, Benjamin
2014-12-01
In his book Multimedia Learning [7], Richard Mayer asserts that viewers learn best from imagery that provides them with cues to help them organize new information into the correct knowledge structures. Designers have long been exploiting the Gestalt laws of visual grouping to deliver viewers those cues using visual hierarchy, often communicating structures much more complex than the simple organizations studied in psychological research. Unfortunately, designers are largely practical in their work, and have not paused to build a complex theory of structural communication. If we are to build a tool to help novices create effective and well structured visuals, we need a better understanding of how to create them. Our work takes a first step toward addressing this lack, studying how five of the many grouping cues (proximity, color similarity, common region, connectivity, and alignment) can be effectively combined to communicate structured text and imagery from real world examples. To measure the effectiveness of this structural communication, we applied a digital version of card sorting, a method widely used in anthropology and cognitive science to extract cognitive structures. We then used tree edit distance to measure the difference between perceived and communicated structures. Our most significant findings are: 1) with careful design, complex structure can be communicated clearly; 2) communicating complex structure is best done with multiple reinforcing grouping cues; 3) common region (use of containers such as boxes) is particularly effective at communicating structure; and 4) alignment is a weak structural communicator.
Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.
Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P
2008-12-01
The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p < 0.05). Sufficient vision penalization can be achieved to make occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.
The Etiology of Presbyopia, Contributing Factors, and Future Correction Methods
NASA Astrophysics Data System (ADS)
Hickenbotham, Adam Lyle
Presbyopia has been a complicated problem for clinicians and researchers for centuries. Defining what constitutes presbyopia and what are its primary causes has long been a struggle for the vision and scientific community. Although presbyopia is a normal aging process of the eye, the continuous and gradual loss of accommodation is often dreaded and feared. If presbyopia were to be considered a disease, its global burden would be enormous as it affects more than a billion people worldwide. In this dissertation, I explore factors associated with presbyopia and develop a model for explaining the onset of presbyopia. In this model, the onset of presbyopia is associated primarily with three factors; depth of focus, focusing ability (accommodation), and habitual reading (or task) distance. If any of these three factors could be altered sufficiently, the onset of presbyopia could be delayed or prevented. Based on this model, I then examine possible optical methods that would be effective in correcting for presbyopia by expanding depth of focus. Two methods that have been show to be effective at expanding depth of focus include utilizing a small pupil aperture or generating higher order aberrations, particularly spherical aberration. I compare these two optical methods through the use of simulated designs, monitor testing, and visual performance metrics and then apply them in subjects through an adaptive optics system that corrects aberrations through a wavefront aberrometer and deformable mirror. I then summarize my findings and speculate about the future of presbyopia correction.
Kudoh, Nobuo
2005-01-01
Walking without vision to previously viewed targets was compared with visual perception of allocentric distance in two experiments. Experimental evidence had shown that physically equal distances in a sagittal plane on the ground were perceptually underestimated as compared with those in a frontoparallel plane, even under full-cue conditions. In spite of this perceptual anisotropy of space, Loomis et al (1992 Journal of Experimental Psychology. Human Perception and Performance 18 906-921) found that subjects could match both types of distances in a blind-walking task. In experiment 1 of the present study, subjects were required to reproduce the extent of allocentric distance between two targets by either walking towards the targets, or by walking in a direction incompatible with the locations of the targets. The latter condition required subjects to derive an accurate allocentric distance from information based on the perceived locations of the two targets. The walked distance in the two conditions was almost identical whether the two targets were presented in depth (depth-presentation condition) or in the frontoparallel plane (width-presentation condition). The results of a perceptual-matching task showed that the depth distances had to be much greater than the width distances in order to be judged to be equal in length (depth compression). In experiment 2, subjects were required to reproduce the extent of allocentric distance from the viewing point by blindly walking in a direction other than toward the targets. The walked distance in the depth-presentation condition was shorter than that in the width-presentation condition. This anisotropy in motor responses, however, was mainly caused by apparent overestimation of length oriented in width, not by depth compression. In addition, the walked distances were much better scaled than those in experiment 1. These results suggest that the perceptual and motor systems share a common representation of the location of targets, whereas a dissociation in allocentric distance exists between the two systems in full-cue conditions.
Kim, Jahae; Cho, Sang-Geon; Song, Minchul; Kang, Sae-Ryung; Kwon, Seong Young; Choi, Kang-Ho; Choi, Seong-Min; Kim, Byeong-Chae; Song, Ho-Chun
2016-01-01
Abstract To compare diagnostic performance and confidence of a standard visual reading and combined 3-dimensional stereotactic surface projection (3D-SSP) results to discriminate between Alzheimer disease (AD)/mild cognitive impairment (MCI), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD). [18F]fluorodeoxyglucose (FDG) PET brain images were obtained from 120 patients (64 AD/MCI, 38 DLB, and 18 FTD) who were clinically confirmed over 2 years follow-up. Three nuclear medicine physicians performed the diagnosis and rated diagnostic confidence twice; once by standard visual methods, and once by adding of 3D-SSP. Diagnostic performance and confidence were compared between the 2 methods. 3D-SSP showed higher sensitivity, specificity, accuracy, positive, and negative predictive values to discriminate different types of dementia compared with the visual method alone, except for AD/MCI specificity and FTD sensitivity. Correction of misdiagnosis after adding 3D-SSP images was greatest for AD/MCI (56%), followed by DLB (13%) and FTD (11%). Diagnostic confidence also increased in DLB (visual: 3.2; 3D-SSP: 4.1; P < 0.001), followed by AD/MCI (visual: 3.1; 3D-SSP: 3.8; P = 0.002) and FTD (visual: 3.5; 3D-SSP: 4.2; P = 0.022). Overall, 154/360 (43%) cases had a corrected misdiagnosis or improved diagnostic confidence for the correct diagnosis. The addition of 3D-SSP images to visual analysis helped to discriminate different types of dementia in FDG PET scans, by correcting misdiagnoses and enhancing diagnostic confidence in the correct diagnosis. Improvement of diagnostic accuracy and confidence by 3D-SSP images might help to determine the cause of dementia and appropriate treatment. PMID:27930593
ERIC Educational Resources Information Center
Trief, Ellen; Decker, Lisa M.; Ryan, Daniel J.
2004-01-01
Since 1920, the Hadley School for the Blind in Winnetka, Illinois, has provided distance learning (via correspondence courses) to individuals who are visually impaired (that is, are blind or have low vision) and their families to support the acquisition of specialized skills and to attain the knowledge needed for full participation in life…
ERIC Educational Resources Information Center
Kirkwood, Adrian
The first of two papers in this report, "The Present and the Future of Audio-Visual Production Centres in Distance Universities," describes changes in the Open University in Great Britain. The Open University's use of television and audio materials are increasingly being distributed to students on cassette. Although transmission is still…
49 CFR 325.73 - Microphone distance correction factors. 1
Code of Federal Regulations, 2013 CFR
2013-10-01
... the observed sound level reading is— 31 feet (9.5 m) or more but less than 35 feet (10.7 m) −4 35 feet... more but less than 83 feet (25.3 m) +2 [40 FR 42437, Sept. 12, 1975, as amended at 54 FR 50385, Dec. 6... 49 Transportation 5 2013-10-01 2013-10-01 false Microphone distance correction factors. 1 325.73...
49 CFR 325.73 - Microphone distance correction factors. 1
Code of Federal Regulations, 2012 CFR
2012-10-01
... the observed sound level reading is— 31 feet (9.5 m) or more but less than 35 feet (10.7 m) −4 35 feet... more but less than 83 feet (25.3 m) +2 [40 FR 42437, Sept. 12, 1975, as amended at 54 FR 50385, Dec. 6... 49 Transportation 5 2012-10-01 2012-10-01 false Microphone distance correction factors. 1 325.73...
49 CFR 325.73 - Microphone distance correction factors. 1
Code of Federal Regulations, 2014 CFR
2014-10-01
... the observed sound level reading is— 31 feet (9.5 m) or more but less than 35 feet (10.7 m) −4 35 feet... more but less than 83 feet (25.3 m) +2 [40 FR 42437, Sept. 12, 1975, as amended at 54 FR 50385, Dec. 6... 49 Transportation 5 2014-10-01 2014-10-01 false Microphone distance correction factors. 1 325.73...
Tejero, Pilar; Insa, Beatriz; Roca, Javier
2018-08-01
Would an increase in the default interletter spacing improve the legibility of words in traffic signs? Previous evidence on traffic sign design and recent studies on the cognitive processes involved in visual word recognition have provided conflicting results. The present work examined whether an increase in the default interletter spacing would improve the search of a word in direction traffic signs. To achieve this objective, twenty-two drivers participated in a driving simulation experiment. They followed a highway route and indicated whether a target place name was present among a set of distractors shown on direction traffic signs along the route. We compared the default interletter spacing of the Spanish "CC Rige" font (which is based on the internationally-used Transport font) and a 2.5-times expanded interletter spacing. The results revealed that the drivers were able to give a correct response at a distance to the traffic sign that was on average longer in the expanded than in the default spacing condition. This advantage in the legibility distance was observed in the absence of significant differences in reading accuracy, gaze behavior, or driving performance measures. Therefore, the evidence provided supports that drivers can benefit from a slight increase in interletter spacing relative to the standard spacing. Some of the design factors influencing this effect are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... who are well adapted to intraocular lens implant or contact lens correction, visual field examinations.... For aphakic individuals not well adapted to contact lens correction or pseudophakic individuals not... meridians 221/2 degrees apart for each eye and indicate the Goldmann equivalent used. See Table III for the...
Code of Federal Regulations, 2010 CFR
2010-07-01
... who are well adapted to intraocular lens implant or contact lens correction, visual field examinations.... For aphakic individuals not well adapted to contact lens correction or pseudophakic individuals not... meridians 221/2 degrees apart for each eye and indicate the Goldmann equivalent used. See Table III for the...
Automatic focusing in digital holography and its application to stretched holograms.
Memmolo, P; Distante, C; Paturzo, M; Finizio, A; Ferraro, P; Javidi, B
2011-05-15
The searching and recovering of the correct reconstruction distance in digital holography (DH) can be a cumbersome and subjective procedure. Here we report on an algorithm for automatically estimating the in-focus image and recovering the correct reconstruction distance for speckle holograms. We have tested the approach in determining the reconstruction distances of stretched digital holograms. Stretching a hologram with a variable elongation parameter makes it possible to change the in-focus distance of the reconstructed image. In this way, the proposed algorithm can be verified at different distances by dispensing the recording of different holograms. Experimental results are shown with the aim of demonstrating the usefulness of the proposed method, and a comparative analysis has been performed with respect to other existing algorithms developed for DH. © 2011 Optical Society of America
Cumulative sum analysis score and phacoemulsification competency learning curve.
Vedana, Gustavo; Cardoso, Filipe G; Marcon, Alexandre S; Araújo, Licio E K; Zanon, Matheus; Birriel, Daniella C; Watte, Guilherme; Jun, Albert S
2017-01-01
To use the cumulative sum analysis score (CUSUM) to construct objectively the learning curve of phacoemulsification competency. Three second-year residents and an experienced consultant were monitored for a series of 70 phacoemulsification cases each and had their series analysed by CUSUM regarding posterior capsule rupture (PCR) and best-corrected visual acuity. The acceptable rate for PCR was <5% (lower limit h) and the unacceptable rate was >10% (upper limit h). The acceptable rate for best-corrected visual acuity worse than 20/40 was <10% (lower limit h) and the unacceptable rate was >20% (upper limit h). The area between lower limit h and upper limit h is called the decision interval. There was no statistically significant difference in the mean age, sex or cataract grades between groups. The first trainee achieved PCR CUSUM competency at his 22 nd case. His best-corrected visual acuity CUSUM was in the decision interval from his third case and stayed there until the end, never reaching competency. The second trainee achieved PCR CUSUM competency at his 39 th case. He could reach best-corrected visual acuity CUSUM competency at his 22 nd case. The third trainee achieved PCR CUSUM competency at his 41 st case. He reached best-corrected visual acuity CUSUM competency at his 14 th case. The learning curve of competency in phacoemulsification is constructed by CUSUM and in average took 38 cases for each trainee to achieve it.
Nanavaty, Mayank A; Vasavada, Abhay R; Patel, Anil S; Raj, Shetal M; Desai, Tejas H
2006-07-01
To analyze factors contributing to uncorrected visual acuity of at least 6/12 for distance and at least J4 for near (pseudoaccommodation) after monofocal intraocular lens (IOL) implantation. Iladevi Cataract and IOL Research Center, Ahmedabad, India. In a case-controlled study of 30 eyes (30 patients) that had phacoemulsification, those with pseudoaccommodation were assigned to cases and 30 eyes (30 patients) without pseudoaccommodation were designated as controls. Controls were matched by identical best corrected visual acuity, age, and postoperative duration. Subjective refraction was done with retinoscopy. Factors analyzed included corneal astigmatism, pupil size, axial IOL movement, amplitude of accommodation, axial length (AL), and age. Corneal astigmatism was noted on topography and interpreted as against the rule (ATR) (180 +/- 15 degrees), with the rule (WTR) (90 +/- 15 degrees), and oblique (OB) (45/135 +/- 30 degrees). Pupil size was noted on topographic display and AL and anterior chamber depth (ACD) on immersion A-scan. The axial IOL movement was calculated as the difference in ACD after instillation of cyclopentolate 1% (Cyclopent) and subsequently pilocarpine nitrate 2% (Carpinol) at separate visits, and amplitude of accommodation was measured with static and dynamic retinoscopy. Multivariate logistic regression and odds ratio with 95% confidence intervals were determined. Mean spherical equivalent was -0.45 +/- 0.63 diopter (D) in cases and -0.35 +/- 0.83 D (P = .61) in controls. Multivariate logistic regression in cases versus controls: corneal astigmatism (ATR versus WTR and OB collectively): 10.19 [1.8,57.44], P = .009; pupil size: 0.45 [0.07,2.71], P = .38; axial IOL movement: 1.39 [0.51,0.77], P = .514; amplitude of accommodation: 2.95 [0.93,9.3], P = .065; AL: 0.55 [0.29,1.02], P = .058; and age: 0.98 [0.5,1.95], P = .963. The study suggests a significant role of ATR corneal astigmatism in good uncorrected distance and near vision after monofocal IOL implantation.
Hashemi, Hassan; Ghaffari, Reza; Miraftab, Mohammad; Asgari, Soheila
2017-08-01
To compare 18-month outcomes between femtosecond laser-assisted LASIK (femto-LASIK) and photorefractive keratectomy with mitomycin-C (PRK-MMC) for myopia of more than 7.0 D in terms of visual acuity and quality. In this comparative nonrandomized clinical trial, 60 eyes from 30 patients (30 eyes in each group) were enrolled. The two procedures were compared in terms of 18-month changes in uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction spherical equivalent, ocular and corneal higher order aberrations (HOAs), and contrast sensitivity (CS). Mean myopia was -8.65 ± 1.51 and -8.04 ± 1.70 D (P = 0.149) and mean ablation depth was 109.37 ± 9.07 and 105.09 ± 12.59 µm (P = 0.138), in the femto-LASIK and PRK-MMC groups, respectively. Baseline parameters were not significantly different between the two groups (all P > 0.05). At 18 months postoperatively, 75 % in the femto-LASIK, versus 57.1 % in the PRK-MMC group, had 20/20 UDVA (P = 0.017). CDVA remained similarly unchanged in both groups (P = 0.616). No case had residual refractive error more than 1.0 D in the femto-LASIK group, while 33.5 % in the other group had more than 1.0 D residual error (P = 0.390). Changes in corneal HOA were not significantly different between the two groups (P = 0.260). Cases in the femto-LASIK group showed more increase in ocular HOA (P = 0.032) and coma (P = 0.083, power = 72 %). CS remained similarly unchanged in all spatial frequencies in both groups (all P > 0.05). Although femto-LASIK induces more HOA compared to PRK-MMC, considering outcomes in terms of 20/20 UDVA, residual refractive error, and CS stability, femto-LASIK provides more favorable results than PRK-MMC in high myopia.
Distance Learners' Perspective on User-Friendly Instructional Materials at the University of Zambia
ERIC Educational Resources Information Center
Simui, F.; Thompson, L. C.; Mundende, K.; Mwewa, G.; Kakana, F.; Chishiba, A.; Namangala, B.
2017-01-01
This case study focuses on print-based instructional materials available to distance education learners at the University of Zambia. Using the Visual Paradigm Software, we model distance education learners' voices into sociograms to make a contribution to the ongoing discourse on quality distance learning in poorly resourced communities. Emerging…
The visual perception of size and distance.
DOT National Transportation Integrated Search
1962-07-01
The perception of absolute distance has been assumed to be important in the perception of the size of objects and the depth between them. A different hypothesis is proposed. It is asserted that perceived relative size and distance are the primary psy...
Corridor One:An Integrated Distance Visualization Enuronments for SSI+ASCI Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Christopher R. Johnson, Charles D. Hansen
2001-10-29
The goal of Corridor One: An Integrated Distance Visualization Environment for ASCI and SSI Application was to combine the forces of six leading edge laboratories working in the areas of visualization and distributed computing and high performance networking (Argonne National Laboratory, Lawrence Berkeley National Laboratory, Los Alamos National Laboratory, University of Illinois, University of Utah and Princeton University) to develop and deploy the most advanced integrated distance visualization environment for large-scale scientific visualization and demonstrate it on applications relevant to the DOE SSI and ASCI programs. The Corridor One team brought world class expertise in parallel rendering, deep image basedmore » rendering, immersive environment technology, large-format multi-projector wall based displays, volume and surface visualization algorithms, collaboration tools and streaming media technology, network protocols for image transmission, high-performance networking, quality of service technology and distributed computing middleware. Our strategy was to build on the very successful teams that produced the I-WAY, ''Computational Grids'' and CAVE technology and to add these to the teams that have developed the fastest parallel visualizations systems and the most widely used networking infrastructure for multicast and distributed media. Unfortunately, just as we were getting going on the Corridor One project, DOE cut the program after the first year. As such, our final report consists of our progress during year one of the grant.« less
The influence of visual contextual information on the emergence of the especial skill in basketball.
Stöckel, Tino; Breslin, Gavin
2013-10-01
We examined whether basketball throwing performance in general and motor skill specificity from the free throw distance in particular are influenced by visual contextual information. Experienced basketball players (N = 36) performed basketball set shots at five distances from the basket. Of particular interest was the performance from the free throw distance (4.23 m), at which experienced basketball players are expected to show superior performance compared with nearby locations as a result of massive amounts of practice. Whereas a control group performed the shots on a regular basketball court, the distance between the rim and the free throw line was either increased or decreased by 30 cm in two experimental groups. Findings showed that only the control group had a superior performance from the free throw distance, and the experimental groups did not. Moreover, all groups performed more accurately from the perceived free throw line (independent of its location) compared with nearby locations. The findings suggest that visual context information influences the presence of specificity effects in experienced performers. The findings have theoretical implications for explaining the memory representation underlying the especial skill effect in basketball.
Influence of viewing distance and size of tv on visual fatigue and feeling of involvement.
Sakamoto, Kiyomi; Asahara, Shigeo; Yamashita, Kuniko; Okada, Akira
2012-12-01
Using physiological and psychological measurements, we carried out experiments to investigate the influence of viewing distance and TV screen size on visual fatigue and feeling of involvement using 17-inch, 42-inch and 65-inch displays. The experiment was an ordinary viewing test with the content similar to everyday TV programs for one hour including scenery, sport, drama, etc., with commercials sandwiched in between. The number of participants was 16 (8 persons aged 21-31, and 8 persons aged 50-70) for each display size. In all, 48 participants viewed 3 display sizes. In our physiological evaluation, CFF (critical flicker fusion frequency), blink rate and a sympathetic nerve activity index were used; and in the psychological evaluation, questionnaires and interviews were employed. Our results, based on physiological and psychological measurements, suggest the opti- mum viewing distance to be around 165-220 cm, irrespective of screen size. Our evaluations, which are based on optimum viewing distance for minimal visual fatigue and a closer feeling of involvement, might therefore not agree with the currently recommended viewing distance, which is defined as 2 or 3 times the display's height.
Effect of dual-focus soft contact lens wear on axial myopia progression in children.
Anstice, Nicola S; Phillips, John R
2011-06-01
To test the efficacy of an experimental Dual-Focus (DF) soft contact lens in reducing myopia progression. Prospective, randomized, paired-eye control, investigator-masked trial with cross-over. Forty children, 11-14 years old, with mean spherical equivalent refraction (SER) of -2.71 ± 1.10 diopters (D). Dual-Focus lenses had a central zone that corrected refractive error and concentric treatment zones that created 2.00 D of simultaneous myopic retinal defocus during distance and near viewing. Control was a single vision distance (SVD) lens with the same parameters but without treatment zones. Children wore a DF lens in 1 randomly assigned eye and an SVD lens in the fellow eye for 10 months (period 1). Lens assignment was then swapped between eyes, and lenses were worn for a further 10 months (period 2). Primary outcome was change in SER measured by cycloplegic autorefraction over 10 months. Secondary outcome was a change in axial eye length (AXL) measured by partial coherence interferometry over 10 months. Accommodation wearing DF lenses was assessed using an open-field autorefractor. In period 1, the mean change in SER with DF lenses (-0.44 ± 0.33 D) was less than with SVD lenses (-0.69 ± 0.38 D; P < 0.001); mean increase in AXL was also less with DF lenses (0.11 ± 0.09 mm) than with SVD lenses (0.22 ± 0.10 mm; P < 0.001). In 70% of the children, myopia progression was reduced by 30% or more in the eye wearing the DF lens relative to that wearing the SVD lens. Similar reductions in myopia progression and axial eye elongation were also observed with DF lens wear during period 2. Visual acuity and contrast sensitivity with DF lenses were not significantly different than with SVD lenses. Accommodation to a target at 40 cm was driven through the central distance-correction zone of the DF lens. Dual-Focus lenses provided normal acuity and contrast sensitivity and allowed accommodation to near targets. Myopia progression and eye elongation were reduced significantly in eyes wearing DF lenses. The data suggest that sustained myopic defocus, even when presented to the retina simultaneously with a clear image, can act to slow myopia progression without compromising visual function. Proprietary or commercial disclosure may be found after the references. Copyright © 2011 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
Distance effect on the behavior of an impinging swirling jet by PIV and flow visualizations
NASA Astrophysics Data System (ADS)
Felli, Mario; Falchi, Massimo; Pereira, Francisco Josè Alves
2010-02-01
The present paper deals with the problem of an impinging swirling jet against a wall. The study concerned a detailed experimental investigation on the jet-wall interaction using PIV and flow visualizations over a range of operating conditions in which the distance of the ducted propeller from the wall was changed. The influence of the impingement distance and the swirl number (i.e., ratio between the axial fluxes of the swirl and the axial momentum) as well as the interaction between the jet deformation and the perturbation induced on the wall is discussed in this paper.
Wolffsohn, James S; Palmer, Eshmael; Rubinstein, Martin; Eperjesi, Frank
2012-09-01
As light-emitting diodes become more common as the light source for low vision aids, the effect of illumination colour temperature on magnifier reading performance was investigated. Reading ability (maximum reading speed, critical print size, threshold near visual acuity) using Radner charts and subjective preference was assessed for 107 participants with visual impairment using three stand magnifiers with light emitting diode illumination colour temperatures of 2,700 K, 4,500 K and 6,000 K. The results were compared with distance visual acuity, prescribed magnification, age and the primary cause of visual impairment. Reading speed, critical print size and near visual acuity were unaffected by illumination colour temperature (p > 0.05). Reading metrics decreased with worsening acuity and higher levels of prescribed magnification but acuity was unaffected by age. Each colour temperature was preferred and disliked by a similar number of patients and was unrelated to distance visual acuity, prescribed magnification and age (p > 0.05). Patients had better near acuity (p = 0.002), critical print size (p = 0.034) and maximum reading speed (p < 0.001), and the improvement in near from distance acuity was greater (p = 0.004) with their preferred rather than least-liked colour temperature illumination. A range of colour temperature illuminations should be offered to all visually impaired individuals prescribed with an optical magnifier for near tasks to optimise subjective and objective benefits. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.
Bilateral Keratoconus Induced by Secondary Hypothyroidism After Radioactive Iodine Therapy.
Lee, Ramon; Hafezi, Farhad; Randleman, J Bradley
2018-05-01
To present a case of new-onset, bilateral, rapidly progressive keratoconus induced by secondary hypothyroidism after radioactive iodine therapy during the sixth decade of life that was successfully treated with corneal cross-linking. Case report and literature review. A 53-year-old woman with no ocular complaints but with a history of Graves' disease and thyrotoxicosis was treated with radioactive iodine therapy and oral levothyroxine for secondary acquired hypothyroidism 3 years prior. Initially, uncorrected distance visual acuity (UDVA) was 20/40 and corrected distance visual acuity (CDVA) was 20/25 in both eyes. Over the following 3 years, the patient developed worsening UDVA and CDVA, with increasing manifest astigmatism of greater than 7.00 diopters (D) in the right eye and 4.75 D in the left eye, with corneal thinning and focal steepening and was diagnosed as having bilateral progressive keratoconus. The patient underwent sequential corneal cross-linking with resultant postoperative CDVA of 20/20 and reduced maximum keratometry and manifest astigmatism in both eyes. The patient's thyroid levels were within normal limits throughout the clinical course. This case provides evidence of the relationship between keratoconus development and thyroid gland dysfunction. The pathophysiology of this relationship has yet to be completely elucidated, but elevated levels of thyroxine in the aqueous humor and tear film and thyroxine receptors in the cornea likely play a role. Screening topographies for patients with thyroid gland dysfunction may be of value for these higher risk patients. [J Refract Surg. 2018;34(5):351-353.]. Copyright 2018, SLACK Incorporated.
Trial Frame Refraction versus Autorefraction among New Patients in a Low-Vision Clinic
DeCarlo, Dawn K.; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia
2013-01-01
Purpose. To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. Methods. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Results. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J0 and J45 were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (−8.6 to 4.9). Conclusions. Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction. PMID:23188726
Cellular Therapy With Human Autologous Adipose-Derived Adult Stem Cells for Advanced Keratoconus.
Alió Del Barrio, Jorge L; El Zarif, Mona; de Miguel, María P; Azaar, Albert; Makdissy, Norman; Harb, Walid; El Achkar, Ibrahim; Arnalich-Montiel, Francisco; Alió, Jorge L
2017-08-01
The aim of this phase 1 study was to preliminarily evaluate the safety and efficacy of autologous adipose-derived adult stem cell (ADASC) implantation within the corneal stroma of patients with advanced keratoconus. Five consecutive patients were selected. Autologous ADASCs were obtained by elective liposuction. ADASCs (3 × 10) contained in 1 mL saline were injected into the corneal stroma through a femtosecond-assisted 9.5-mm diameter lamellar pocket under topical anesthesia. Patients were reviewed at 1 day, 1 week, 1, 3, and 6 months postoperatively. Visual function, manifest refraction, slit-lamp biomicroscopy, intraocular pressure, endothelial cell density, corneal topography, corneal optical coherence tomography, and corneal confocal biomicroscopy were recorded. No intraoperative or postoperative complications were recorded, with full corneal transparency recovery within 24 hours. Four patients completed the full follow-up. All patients improved their visual function (mean: 1 line of unaided and spectacle-corrected distance vision and 2 lines of rigid contact lens distance vision). Manifest refraction and topographic keratometry remained stable. Corneal optical coherence tomography showed a mean improvement of 16.5 μm in the central corneal thickness, and new collagen production was observed as patchy hyperreflective areas at the level of the stromal pocket. Confocal biomicroscopy confirmed the survival of the implanted stem cells at the surgical plane. Intraocular pressure and endothelial cell density remained stable. Cellular therapy of the human corneal stroma in vivo with autologous ADASCs appears to be safe. Stem cells survive in vivo with intrastromal new collagen production. Future studies with larger samples are required to confirm these preliminary results.
Hashemian, Hesam; Jabbarvand, Mahmoud; Khodaparast, Mehdi; Ameli, Kambiz
2014-12-01
To evaluate the outcome of accelerated and conventional corneal cross-linking (CXL) procedures regarding their effect on morphological and optical properties of the cornea. One hundred fifty-three eyes of 153 patients were evaluated before and during a 15-month follow-up period after CXL (76 eyes in the conventional group and 77 eyes in the accelerated group). Measured variables include corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), refraction, maximum keratometry, endothelial cell density, anterior and posterior stromal keratocyte density, and subbasal nerve density. All variables were compared between the two study groups. Cylindrical and spherical components of refraction improved significantly during 15 months of follow-up. No difference was observed between the two study groups. UDVA and CDVA improved in the same manner, with no intergroup differences. Endothelial cell density did not change significantly during the follow-up period in either group. K-max increased slightly in the first month of the follow-up, but started to decrease at postoperative visits without any significant difference in the two groups. Anterior stromal keratocyte density and subbasal nerve density decreased significantly in both groups 1 month postoperatively. Both variables had a more significant decrease in the conventional group at all visits before the 1-year visit. At the final 15-month visit, there were no significant differences in any value between the two groups. Accelerated and conventional CXL seem to have a comparable and acceptable effect on keratoconus in the short-term follow-up period. Copyright 2014, SLACK Incorporated.
Tabernero, Juan; Artal, Pablo
2012-02-01
To determine the optimum position to center a small-aperture corneal inlay and the effect of residual defocus in the surgical eye to maximize depth of focus. Laboratorio de Óptica, Universidad de Murcia, Murcia, Spain. Cohort study. Personalized eye models were built using actual data (corneal topography, eye length, ocular aberrations, and eye alignment). A small aperture 1.6 mm in diameter was placed at the corneal plane in each model. The monochromatic and polychromatic Strehl ratios were calculated as a function of the pinhole position. Different residual defocus values were also incorporated into the models, and the through-focus Strehl ratios were calculated. Sixteen eye models were built. For most subjects, the optimum location of the aperture for distance vision was close to the corneal reflex position. For a given optimized centration of the aperture, the best compromise of depth of focus was obtained when the eyes had some residual myopic defocus (range -0.75 to -1.00 diopter [D]). Strehl ratio values were over 0.1 for far distance, which led to visual acuities better than 20/20. The depth of focus was 2.50 D with a mean near visual acuity of Jaeger 1 or better. In eyes with little astigmatism and aberrations, the optimum centration of the small aperture was near the corneal reflex position. To improve optical outcomes with the inlay, some small residual myopia and correction of corneal astigmatism might be required. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Dausch, Dieter; Dausch, Burglinde; Wottke, Matthias; Sluyterman van Langeweyde, Georg
2014-01-01
One hundred eyes from 55 adult patients with myopia were retrospectively studied to determine the comparative safety, efficacy, and predictability of aberration smart ablation (ASA) and a new advanced ablation algorithm (Triple-A) using the MEL(®) 80 excimer laser. Fifty myopic eyes with a manifest refraction spherical equivalent (MRSE) between -1.0 diopters (D) and -9.75 D were consecutively treated with photorefractive keratec-tomy ASA, and 50 myopic eyes with an MRSE between -1.38 D and -11.0 D with photorefractive keratectomy Triple-A. Uncorrected distance visual acuity, MRSE, the absolute value of the cylinder, corrected distance visual acuity, and postoperative complications at 1 month, 3 months, 6 months, and 12 months (1 year) were descriptively analyzed and compared at 1 year. After 12 months, the MRSE variance was statistically significantly better in patients triaged to receive Triple-A compared with patients receiving ASA (ASA, ±0.7 D; Triple-A, ±0.15 D; P<0.001). Furthermore, no patient in the Triple-A group had any cylinder postoperatively. Patients in the Triple-A treatment arm achieved a superior result. No statistically significant difference in the two treatment arms was noted for the analysis of the mean MRSE at 12 months (P=0.78). Triple-A was more effective than standard aspherical surgical intervention in a number of treatment outcome parameters (eg, MRSE, astigmatism, efficacy index). The two surgical procedures were equivalent in terms of safety.
Cicatricial changes in ocular pemphigus
Chirinos-Saldaña, P; Zuñiga-Gonzalez, I; Hernandez-Camarena, J C; Navas, A; Ramirez-Luquin, T; Robles-Contreras, A; Jimenez-Martinez, M C; Ramirez-Miranda, A; Bautista-de Lucio, V M; Graue-Hernandez, E O
2014-01-01
Purpose To describe the clinical characteristics of ocular involvement in patients with pemphigus at an ophthalmological referral center. Methods A retrospective review was conducted on patients with the immunopathological diagnosis of pemphigus examined between 1 January 2000 and 1 April 2010. Uncorrected distance visual acuity (UDVA), best corrected distance visual acuity (BCVA), ocular symptoms, and ocular surface inflammatory and scarring changes were assessed. Results A total of 15 patients were identified, with a mean age of 68.27±14.35 years, and 80% (n=12) were female. Extraocular involvement was reported in one patient. All of the eyes showed cicatricial changes in the conjunctiva. In all, 6 eyes (20%) were classified as stage I; 12 eyes (40%) as stage II; 10 eyes (33%) as stage III; and 2 eyes (7%) as stage IV. A statistically significant association was found between BCVA and the severity of ocular involvement. The mean BCVA logMAR was 1.66 (20/914), with a range from logMAR 0 (20/20) to logMAR 4 (NLP). Other ocular diseases were found in 8 (53.3%), systemic diseases in 10 (66.7%), and the use of pemphigus-inducing drugs in 10 patients (66.7%). Conclusions The present report represents the largest series of ocular involvement in pemphigus confirmed by immunopathology. The clinical manifestations varied from conjunctival hyperemia to corneal scarring and perforation. There was a strong association between scarring changes and low BCVA. Ocular and systemic diseases as well as the use of pemphigus-inducing drugs may predispose to ocular cicatricial changes observed in this series. PMID:24480839
Tu, Kyaw Lin; Aslanides, Ioannis M
2009-08-01
To analyze anterior corneal elevation changes on Orbscan II following corneal collagen cross-linking (CXL) with riboflavin. This retrospective study included 8 patients (14 eyes) with keratoconus who underwent CXL, with a mean follow-up of 7 months (range: 5 to 10 months). Pre- and postoperative (at last clinic attendance) anterior elevation difference maps were examined for overall patterns of change. On preoperative maps, distances from maximum anterior elevation to pupil center and to topographic geometric center were compared between the two patterns identified. Pre- and postoperative topography, best spectacle-corrected visual acuity (BSCVA), and refraction were also compared between the two patterns. Two patterns of anterior elevation change were visually identified: (1) paracentral steepening, no change, or flattening centrally; and (2) central steepening. The preoperative maps of eyes that manifested pattern 1 had shorter mean distances for maximum anterior elevation to pupil center (1.70 vs. 2.27 mm) and maximum anterior elevation to geometric center (1.45 vs. 1.99 mm) than those that resulted in pattern 2. Mean maximum topographic simulated keratometry decreased (P = .004) and mean irregularity indices at 3 mm (P =.03) and 5 mm (P =.04) were reduced postoperatively in pattern 1 eyes; all increased in pattern 2 eyes. Mean BSCVA improved postoperatively for both patterns. Mean preoperative myopia decreased in pattern 1 eyes by 0.44 diopters (D), whereas it increased for pattern 2 eyes by 1.83 D. Corneal shape change influenced by anisotropy of collagen distribution is a factor in the outcome of CXL treatment for keratoconus.
Trial frame refraction versus autorefraction among new patients in a low-vision clinic.
DeCarlo, Dawn K; McGwin, Gerald; Searcey, Karen; Gao, Liyan; Snow, Marsha; Waterbor, John; Owsley, Cynthia
2013-01-02
To determine the relationship between refractive error as measured by autorefraction and that measured by trial frame refraction among a sample of adults with vision impairment seen in a university-based low-vision clinic and to determine if autorefraction might be a suitable replacement for trial frame refraction. A retrospective chart review of all new patients 19 years or older seen over an 18-month period was conducted and the following data collected: age, sex, primary ocular diagnosis, entering distance visual acuity, habitual correction, trial frame refraction, autorefraction, and distance visual acuity measured after trial frame refraction. Trial frame refraction and autorefraction were compared using paired t-tests, intraclass correlations, and Bland-Altman plots. Final analyses included 440 patients for whom both trial frame refraction and autorefraction data were available for the better eye. Participants were mostly female (59%) with a mean age of 68 years (SD = 20). Age-related macular degeneration was the most common etiology for vision impairment (44%). Values for autorefraction and trial frame refraction were statistically different, but highly correlated for the spherical equivalent power (r = 0.92), the cylinder power (r = 0.80) and overall blurring strength (0.89). Although the values of the cross-cylinders J(0) and J(45) were similar, they were poorly correlated (0.08 and 0.15, respectively). The range of differences in spherical equivalent power was large (-8.6 to 4.9). Autorefraction is highly correlated with trial frame refraction. Differences are sometimes substantial, making autorefraction an unsuitable substitute for trial frame refraction.
NASA Astrophysics Data System (ADS)
Fuchs, Alexander; Pengel, Steffen; Bergmeier, Jan; Kahrs, Lüder A.; Ortmaier, Tobias
2015-07-01
Laser surgery is an established clinical procedure in dental applications, soft tissue ablation, and ophthalmology. The presented experimental set-up for closed-loop control of laser bone ablation addresses a feedback system and enables safe ablation towards anatomical structures that usually would have high risk of damage. This study is based on combined working volumes of optical coherence tomography (OCT) and Er:YAG cutting laser. High level of automation in fast image data processing and tissue treatment enables reproducible results and shortens the time in the operating room. For registration of the two coordinate systems a cross-like incision is ablated with the Er:YAG laser and segmented with OCT in three distances. The resulting Er:YAG coordinate system is reconstructed. A parameter list defines multiple sets of laser parameters including discrete and specific ablation rates as ablation model. The control algorithm uses this model to plan corrective laser paths for each set of laser parameters and dynamically adapts the distance of the laser focus. With this iterative control cycle consisting of image processing, path planning, ablation, and moistening of tissue the target geometry and desired depth are approximated until no further corrective laser paths can be set. The achieved depth stays within the tolerances of the parameter set with the smallest ablation rate. Specimen trials with fresh porcine bone have been conducted to prove the functionality of the developed concept. Flat bottom surfaces and sharp edges of the outline without visual signs of thermal damage verify the feasibility of automated, OCT controlled laser bone ablation with minimal process time.
Psychophysics of the McGurk and Other Audiovisual Speech Integration Effects
ERIC Educational Resources Information Center
Jiang, Jintao; Bernstein, Lynne E.
2011-01-01
When the auditory and visual components of spoken audiovisual nonsense syllables are mismatched, perceivers produce four different types of perceptual responses, auditory correct, visual correct, fusion (the so-called "McGurk effect"), and combination (i.e., two consonants are reported). Here, quantitative measures were developed to account for…
Kim, Dong Yoon; Jo, Jaehyuck; Joe, Soo Geun; Kim, June-Gone; Yoon, Young Hee; Lee, Joo Yong
2017-02-01
To compare the visual prognosis and clinical features of cytomegalovirus (CMV) retinitis between HIV and non-HIV patients. Retrospective cross-sectional study on patients diagnosed with CMV retinitis. Depending on the presence of HIV infection, best-corrected visual acuity (VA) and clinical feature of CMV retinitis were analyzed. The clinical characteristics associated with poor visual prognosis after antiviral treatment were also identified. A total of 78 eyes (58 patients) with CMV retinitis were included in this study: 21 eyes and 57 eyes in HIV and non-HIV patients, respectively. Best-corrected VA was not significantly different between HIV and non-HIV patients. The rate of foveal involvement, retinal detachment, involved zone, and mortality did not significantly differ between the two groups. Visual acuity after antiviral treatment was significantly worse (pretreatment logarithm of the minimal angle of resolution best-corrected VA, 0.54 ± 0.67 [Snellen VA, 20/63]; posttreatment logarithm of the minimal angle of resolution best-corrected VA, 0.77 ± 0.94 [Snellen VA, 20/125]; P = 0.014). Poor visual prognosis was significantly associated with Zone 1 involvement, retinal detachment, and a poor general condition. The overall visual prognosis and the clinical features of CMV retinitis do not differ between HIV and non-HIV patients. The visual prognosis of CMV retinitis still remains quite poor despite advancements in antiviral treatment. This poor prognosis after antiviral treatment is associated with retinal detachment during follow-up, Zone 1 involvement, and the poor general condition of the patient.
[The key parameters of design research and analysis of the Chinese reading visual acuity chart].
Wang, Chen-xiao; Liu, Zhi-hui; Gao, Ji-tuo; Guo, Ying-xuan; He, Ji-cang; Qu, Jia; Lü, Fan
2013-06-01
Reading is a visual function human being used to understand environmental events based on writing materials. This study investigated the feasibility of reading visual acuity chart in assessment of reading ability by analysis of the key factors involved in the design of the visual acuity chart. The reading level was determined as grade 3 primary school with Song as the font and 30 characters included in the sentences. Each of the sentences consisted of 27 commonly-used Chinese characters (9 characters between any two punctuations) and 3 punctuations. There were no contextual clues between the 80 sentences selected. The characters had 13 different sizes with an increment of 0.1 log unit (e.g.1.2589) and 2.5 pt was determined as the critical threshold. Readable test for visual target was followed as (1) 29 candidates with a raw or corrected visual acuity (VA)of at least 1.0 were selected to read 80 selected sentences with the size of characters of 2.5 pt at a distance of 40 cm, (2) the time used for reading with the number of characters wrongly read was recorded, (3) 39 sentences were selected as visual targets based on reading speed, effective reading position and total number of character strokes, (4) The 39 selected sentences were then randomly divided into 3 groups with no significant difference among the groups in the 3 factors listed at (3) with paired t-test. This reading visual chart was at level of Grade 3 primary school with a total stroke number of 165-210(Mean 185 ± 10), 13 font sizes a 0.1 log unit increment, a song pattern and 2.5 pt as the critical threshold. All candidates achieved 100% correct in reading test under 2.5 pt with an effective reading speed as 120.65-162 wpm (Mean 142.93 ± 11.80) and effective reading position as 36.03-61.48(Mean 48.85 ± 6.81). The reading test for the 3 groups of sentences showed effective reading speed as (142.49 ± 12.14) wpm,(142.86 ± 12.55) wpm and (143.44 ± 11.63) wpm respectively(t1-2 = -0.899, t2-3 = -1.295, t1-3 = -1.435). The reading position was 48.55 ± 6.69, 48.99 ± 7.49 and 49.00 ± 6.76, respectively(t1-2 = -1.019, t2-3 = -0.019, t1-3 = -0.816). The total number of character strokes was 185.54 ± 7.55, 187.69 ± 13.76 and 182.62 ± 8.17, respectively(t1-2 = 0.191, t2-3 = 1.385, t1-3 = 1.686). A practical design of the Chinese reading visual chart should consider size, increment, legibility in selection of reading sentences. Reading visual acuity, critical threshold and effective reading speed could be used to express the reading visual function.
Zhang, Jiamei; Wang, Yan
2016-01-01
Since sixty percent of ametropes obtain astigmatism, which has influence on the visual quality, correcting the astigmatism is always the focus of concerns during visual correction procedures especially for the corneal refractive surgery. The postoperative spherical equivalent or residual cylindrical dioptors was used as quantitative index to evaluate the correction of astigmatism previously; however, such results neglect the effect of astigmatic axis shift on the treatment. Taking astigmatism as a vector parameter could describe the magnitude and direction of astigmatism accurately, thus it was increasingly applied in the evaluation of astigmatism correction. This paper reviews the present vector analysis methods, evaluation indexes and its application for the correction of astigmatism in the corneal refractive surgery.
Effects of Different Levels of Refractive Blur on Nighttime Pedestrian Visibility.
Wood, Joanne M; Marszalek, Ralph; Carberry, Trent; Lacherez, Philippe; Collins, Michael J
2015-07-01
The aim of this study was to systematically investigate the effect of different levels of refractive blur and driver age on nighttime pedestrian recognition and determine whether clothing that has been shown to improve pedestrian conspicuity is robust to the effects of blur. Nighttime pedestrian recognition was measured for 24 visually normal participants (12 younger mean = 24.9 ± 4.5 years and 12 older adults mean = 77.6 ± 5.7 years) for three levels of binocular blur (+0.50 diopter [D], +1.00 D, +2.00 D) compared with baseline (optimal refractive correction). Pedestrians walked in place on a closed road circuit and wore one of three clothing conditions: everyday clothing, a retro-reflective vest, and retro-reflective tape positioned on the extremities in a configuration that conveyed biological motion (known as "biomotion"); the order of conditions was randomized among participants. Pedestrian recognition distances were recorded for each blur and pedestrian clothing combination while participants drove an instrumented vehicle around a closed road course. The recognition distances for pedestrians were significantly reduced (P < 0.05) by all levels of blur compared with baseline. Pedestrians wearing biomotion clothing were recognized at significantly longer distances than for the other clothing configurations in all blur conditions. However, these effects were smaller for the older adults, who had much shorter recognition distances for all conditions tested. In summary, even small amounts of blur had a significant detrimental effect on nighttime pedestrian recognition. Biomotion retro-reflective clothing was effective, even under moderately degraded visibility conditions, for both young and older drivers.
Relationship of the actual thick intraocular lens optic to the thin lens equivalent.
Holladay, J T; Maverick, K J
1998-09-01
To theoretically derive and empirically validate the relationship between the actual thick intraocular lens and the thin lens equivalent. Included in the study were 12 consecutive adult patients ranging in age from 54 to 84 years (mean +/- SD, 73.5 +/- 9.4 years) with best-corrected visual acuity better than 20/40 in each eye. Each patient had bilateral intraocular lens implants of the same style, placed in the same location (bag or sulcus) by the same surgeon. Preoperatively, axial length, keratometry, refraction, and vertex distance were measured. Postoperatively, keratometry, refraction, vertex distance, and the distance from the vertex of the cornea to the anterior vertex of the intraocular lens (AV(PC1)) were measured. Alternatively, the distance (AV(PC1)) was then back-calculated from the vergence formula used for intraocular lens power calculations. The average (+/-SD) of the absolute difference in the two methods was 0.23 +/- 0.18 mm, which would translate to approximately 0.46 diopters. There was no statistical difference between the measured and calculated values; the Pearson product-moment correlation coefficient from linear regression was 0.85 (r2 = .72, F = 56). The average intereye difference was -0.030 mm (SD, 0.141 mm; SEM, 0.043 mm) using the measurement method and +0.124 mm (SD, 0.412 mm; SEM, 0.124 mm) using the calculation method. The relationship between the actual thick intraocular lens and the thin lens equivalent has been determined theoretically and demonstrated empirically. This validation provides the manufacturer and surgeon additional confidence and utility for lens constants used in intraocular lens power calculations.
Sorkin, Nir; Einan-Lifshitz, Adi; Abelson, Sagi; Boutin, Tanguy; Showail, Mahmood; Borovik, Armand; Ashkenazy, Zach; Chan, Clara C; Rootman, David S
2017-11-01
To report the outcome of stepwise ablation using topography-guided photorefractive keratectomy to treat irregular astigmatism after either penetrating keratoplasty (PKP) or deep anterior lamellar keratoplasty (DALK). This is a retrospective, interventional analysis including patients with irregular astigmatism after either PKP or DALK, who underwent topography-guided photorefractive keratectomy. The entire cohort was analyzed, as well as the PKP and DALK groups separately. Analysis of factors associated with a better outcome was also performed. Thirty-four eyes of 34 patients (20 PKP patients and 14 DALK patients) aged 47.4 ± 15.9 years were included. Twenty-one patients underwent more than 1 ablation. Refractive stability and a minimal period of 5 months were required before repeat ablation. The average follow-up duration was 17.0 ± 6.0 months. Corrected distance visual acuity (CDVA) improved significantly from 0.22 ± 0.14 logarithm of the minimum angle of resolution (logMAR) to 0.14 ± 0.12 logMAR at final follow-up (P = 0.035). Uncorrected distance visual acuity (UDVA) improved significantly from 0.90 ± 0.54 logMAR to 0.57 ± 0.40 logMAR at final follow-up (P = 0.004). CDVA and UDVA improved by ≥1 Snellen lines in 54.2% and 70.8% of the eyes, respectively, and by ≥3 Snellen lines in 16.7% and 54.2% of the eyes, respectively. Statistically significant improvement was seen in optical aberrometry indices (total root mean square, higher-order aberration root mean square, defocus, coma, trefoil, and spherical aberration). The difference between PKP and DALK in either CDVA (P = 0.562) or UDVA (P = 0.384) improvement was nonsignificant. The stepwise topography-guided photorefractive keratectomy approach in cases of irregular astigmatism after PKP or DALK can help improve visual acuity outcomes. Patients should be appropriately counseled that more than 1 treatment will likely be needed.
Woodcock, Michael G; Lehmann, Robert; Cionni, Robert J; Breen, Michael; Scott, Maria C
2016-06-01
To compare astigmatic outcomes in patients with bilateral cataracts having toric intraocular lens (IOL) implantation with intraoperative aberrometry measurements in 1 eye and standard power calculation and a toric IOL calculator with inked axis marking in the contralateral eye. Twelve sites in the United States. Prospective cohort study. The eye with the more visually significant cataract was randomized to intraoperative aberrometry measurements (Ocular Response Analyzer with Verifeye) or standard preoperative biometry and use of a toric calculator with the contralateral eye automatically assigned to the other group. The primary effectiveness outcome was the proportion of eyes with a postoperative refractive astigmatism of 0.50 diopter (D) or less at 1 month. Of the 130 patients (260 eyes) enrolled, 124 (248 eyes) were randomized; 121 (242 eyes) completed the trial. The percentage of eyes with astigmatism of 0.50 D or less at 1 month was higher in the intraoperative aberrometry group than in the standard group (89.2% versus 76.6%) (P = .006). The mean postoperative refractive astigmatism was lower in the intraoperative aberrometry group (0.29 D ± 0.28 [SD] versus 0.36 ± 0.35 D) (P = .041). Secondary effectiveness endpoints, including manifest refraction spherical equivalent prediction error, uncorrected distance visual acuity, and corrected distance visual acuity, were similar. Compared with standard methods, the use of the intraoperative aberrometry system increased the proportion of eyes with postoperative refractive astigmatism of 0.50 D or less and reduced the mean postoperative refractive astigmatism at 1 month. Other efficacy outcomes were similar. Drs. Woodcock, Lehmann, and Cionni are consultants to Alcon Laboratories, Inc. Dr. Breen is an employee of Alcon Laboratories, Inc. Dr. Scott has no financial or proprietary interest in any material or method mentioned. Copyright © 2016 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Cleary, Catherine; Li, Yan; Tang, Maolong; Gendy, Nehal Samy El; Huang, David
2014-01-01
Purpose To use Fourier-domain optical coherence tomography (FD-OCT) to predict trans-epithelial phototherapeutic keratectomy (TE-PTK) outcomes. Methods Prospective case series. Subjects with anterior stromal corneal opacities underwent excimer laser PTK combined with PRK using the VISX S4 excimer laser (AMO, Inc., Santa Ana, CA). Pre- and postoperative FD-OCT images were used to develop a simulation algorithm to predict treatment outcomes. Main Outcome Measures Pre- and postoperative uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA). Postoperative corneal thickness and manifest refraction spherical equivalent (MRSE) were analyzed using multivariate linear regression. Results Nine eyes of 8 patients were treated. Nominal ablation depth was 75 – 177 μm centrally and 62 –185 μm peripherally. Measured PTK ablation depths were 20% higher centrally and 26% higher peripherally, compared to laser settings. Postoperatively, mean UDVA was 20/41 (range 20/25 – 20/80) compared to 20/103 (range 20/60 – 20/400) preoperatively. Mean CDVA was 20/29 (range 20/15 – 20/60) compared to 20/45 (range 20/30 – 20/80) preoperatively. MRSE was +1.38±2.37 D compared to −2.59±2.83D (mean±SD). Mean astigmatism magnitude was 1.14±0.83D compared to 1.40±1.18D preoperatively. Postoperative MRSE correlated strongly with ablation settings, central and peripheral epithelial thickness (r=0.99, p<0.00001 ). Central island remained difficult to predict and limited visual outcomes in some cases. Conclusion OCT measurements of opacity depth and 3D ablation simulation provide valuable guidance PTK planning. Post-PTK refraction may be predicted with a regression formula which uses OCT epithelial thickness measurements. Laser ablation rates described in this study only apply to the VisX laser. PMID:24452208
Outcomes of photorefractive keratectomy enhancement after LASIK.
Lee, Bryan S; Gupta, Preeya K; Davis, Elizabeth A; Hardten, David R
2014-08-01
To report the outcomes of photorefractive keratectomy (PRK) enhancement after LASIK for patients diagnosed as having hyperopic and myopic refractive errors. In this retrospective case series at a single private practice in the United States, all patients undergoing PRK enhancement after LASIK were identified. Patients with visually significant cataract, non-plano targets, and follow-up of fewer than 226 days were excluded. The primary outcome measure was uncorrected distance visual acuity (UDVA) with secondary measures of corrected distance visual acuity (CDVA) and postoperative refractive error. Linear regression analysis was performed for actual versus targeted change in spherical equivalent. Mean UDVA improved from 20/39 to 20/24 for hyperopes (n = 14; P < .002) and from 20/45 to 20/22 for myopes (n = 29; P < .0000001) after enhancement. All patients had a UDVA of 20/40 or better at their most recent follow-up visit. Fifty percent of hyperopes and 65.5% of myopes were 20/20 or better. The mean refractive error for hyperopes changed from +1.10 ± 0.71 (range: +0.13 to +2.25 diopters [D]) to +0.38 ± 0.66 D (range: -0.75 to +1.38 D) and from -1.21 ± 0.61 (range: -3.25 to -0.38 D) to +0.34 ± 0.45 D (range: -0.25 to +1.75 D) for myopes. The manifest refraction cylinder decreased from 0.84 to 0.46 D in hyperopes (P = .02) and from 0.64 to 0.26 D in myopes (P < .002). CDVA was maintained in both groups, with only one patient in each worse than 20/20. There was a nonsignificant trend toward less haze in the patients receiving mitomycin C (5.1% vs 25%, P = .14). Linear regression showed a tendency toward overtreatment in the myopic group. PRK is safe and highly effective for patients who previously underwent LASIK and in whom the surgeon would prefer not to perform a flap-lift enhancement. Copyright 2014, SLACK Incorporated.
Özen Tunay, Zuhal; Çalışkan, Deniz; İdil, Aysun; Öztuna, Derya
2016-01-01
Objectives: To determine the clinical features and the distribution of diagnosis in partially sighted school-age children, to report the chosen low vision rehabilitation methods and to emphasize the importance of low vision rehabilitation. Materials and Methods: The study included 150 partially sighted children between the ages of 6 and 18 years. The distribution of diagnosis, accompanying ocular findings, visual acuity of the children both for near and distance with and without low vision devices, and the methods of low vision rehabilitation (for distance and for near) were determined. The demographic characteristics of the children and the parental consanguinity were recorded. Results: The mean age of children was 10.6 years and the median age was 10 years; 88 (58.7%) of them were male and 62 (41.3%) of them were female. According to distribution of diagnoses among the children, the most frequent diagnosis was hereditary fundus dystrophies (36%) followed by cortical visual impairment (18%). The most frequently used rehabilitation methods were: telescopic lenses (91.3%) for distance vision; magnifiers (38.7%) and telemicroscopic systems (26.0%) for near vision. A significant improvement in visual acuity both for distance and near vision were determined with low vision aids. Conclusion: A significant improvement in visual acuity can be achieved both for distance and near vision with low vision rehabilitation in partially sighted school-age children. It is important for ophthalmologists and pediatricians to guide parents and children to low vision rehabilitation. PMID:27800263
Özen Tunay, Zuhal; Çalışkan, Deniz; İdil, Aysun; Öztuna, Derya
2016-04-01
To determine the clinical features and the distribution of diagnosis in partially sighted school-age children, to report the chosen low vision rehabilitation methods and to emphasize the importance of low vision rehabilitation. The study included 150 partially sighted children between the ages of 6 and 18 years. The distribution of diagnosis, accompanying ocular findings, visual acuity of the children both for near and distance with and without low vision devices, and the methods of low vision rehabilitation (for distance and for near) were determined. The demographic characteristics of the children and the parental consanguinity were recorded. The mean age of children was 10.6 years and the median age was 10 years; 88 (58.7%) of them were male and 62 (41.3%) of them were female. According to distribution of diagnoses among the children, the most frequent diagnosis was hereditary fundus dystrophies (36%) followed by cortical visual impairment (18%). The most frequently used rehabilitation methods were: telescopic lenses (91.3%) for distance vision; magnifiers (38.7%) and telemicroscopic systems (26.0%) for near vision. A significant improvement in visual acuity both for distance and near vision were determined with low vision aids. A significant improvement in visual acuity can be achieved both for distance and near vision with low vision rehabilitation in partially sighted school-age children. It is important for ophthalmologists and pediatricians to guide parents and children to low vision rehabilitation.
Rius, Anna; Artazcoz, Lucía; Guisasola, Laura; Benach, Joan
2014-01-01
The objectives of this study were to examine for the first time the prevalence of visual impairment and blindness among adults in Spain, to explore regional differences, and to assess whether they may vary as a function of sex or be explained by age and individual or regional socioeconomic position. Data were obtained from the 2008 Spanish Survey on Disability, Personal Autonomy, and Dependency Situations, a cross-sectional survey based on a representative sample of the noninstitutionalized population of Spain. The sample was composed of 213 626 participants aged ≥15 years (103 093 men and 110 533 women); 360 were blind (160 men and 200 women), 4048 had near visual impairment (1397 men and 2651 women), and 4034 had distance visual impairment (1445 men and 2589 women). The prevalence of near and distance visual impairment was calculated for each region. Multiple logistic regression models were fitted to calculate odds ratios and 95% confidence intervals. All analyses were stratified by sex. Visual impairment was based on 3 questions aimed at identifying blindness and near and distance visual impairment. The prevalence (percentage) of blindness was 0.17 (men, 0.16; women, 0.18): 1.89 for near visual impairment (men, 1.36; women, 2.40), 1.89 for distance visual impairment (men, 1.40; women, 2.34), and 2.43 for any visual impairment (men, 1.81; women, 3.02). Regional inequalities in the prevalence of visual impairment were observed, correlated with regional income, and the prevalence was consistently higher among women than men. The magnitude of the inequalities remained after adjusting for age and educational level, and a north-to-south pattern of increasing prevalence was observed. Regional and sex inequalities in the prevalence of visual impairment and blindness were observed in Spain, with a north-to-south gradient of increasing prevalence that was not explained by age or individual educational level but was correlated with regional level of economic development. Factors that could be prioritized for future policies and research include differential regional economic development, rural environment, quality of eye care services, diabetes, ultraviolet light exposure, or gender inequalities in diagnostic and therapeutic health care. Copyright © 2014 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li Hua; Noel, Camille; Chen, Haijian
Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on amore » Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The {gamma} pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P= 0.0022); bladder (2.15 vs 3.7, P= 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P= 0.0020); rectum (2.8 vs 3.9, P= 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High {gamma} pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists' confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images.« less
Li, Hua; Noel, Camille; Chen, Haijian; Harold Li, H.; Low, Daniel; Moore, Kevin; Klahr, Paul; Michalski, Jeff; Gay, Hiram A.; Thorstad, Wade; Mutic, Sasa
2012-01-01
Purpose: Severe artifacts in kilovoltage-CT simulation images caused by large metallic implants can significantly degrade the conspicuity and apparent CT Hounsfield number of targets and anatomic structures, jeopardize the confidence of anatomical segmentation, and introduce inaccuracies into the radiation therapy treatment planning process. This study evaluated the performance of the first commercial orthopedic metal artifact reduction function (O-MAR) for radiation therapy, and investigated its clinical applications in treatment planning. Methods: Both phantom and clinical data were used for the evaluation. The CIRS electron density phantom with known physical (and electron) density plugs and removable titanium implants was scanned on a Philips Brilliance Big Bore 16-slice CT simulator. The CT Hounsfield numbers of density plugs on both uncorrected and O-MAR corrected images were compared. Treatment planning accuracy was evaluated by comparing simulated dose distributions computed using the true density images, uncorrected images, and O-MAR corrected images. Ten CT image sets of patients with large hip implants were processed with the O-MAR function and evaluated by two radiation oncologists using a five-point score for overall image quality, anatomical conspicuity, and CT Hounsfield number accuracy. By utilizing the same structure contours delineated from the O-MAR corrected images, clinical IMRT treatment plans for five patients were computed on the uncorrected and O-MAR corrected images, respectively, and compared. Results: Results of the phantom study indicated that CT Hounsfield number accuracy and noise were improved on the O-MAR corrected images, especially for images with bilateral metal implants. The γ pass rates of the simulated dose distributions computed on the uncorrected and O-MAR corrected images referenced to those of the true densities were higher than 99.9% (even when using 1% and 3 mm distance-to-agreement criterion), suggesting that dose distributions were clinically identical. In all patient cases, radiation oncologists rated O-MAR corrected images as higher quality. Formerly obscured critical structures were able to be visualized. The overall image quality and the conspicuity in critical organs were significantly improved compared with the uncorrected images: overall quality score (1.35 vs 3.25, P = 0.0022); bladder (2.15 vs 3.7, P = 0.0023); prostate and seminal vesicles/vagina (1.3 vs 3.275, P = 0.0020); rectum (2.8 vs 3.9, P = 0.0021). The noise levels of the selected ROIs were reduced from 93.7 to 38.2 HU. On most cases (8/10), the average CT Hounsfield numbers of the prostate/vagina on the O-MAR corrected images were closer to the referenced value (41.2 HU, an average measured from patients without metal implants) than those on the uncorrected images. High γ pass rates of the five IMRT dose distribution pairs indicated that the dose distributions were not significantly affected by the CT image improvements. Conclusions: Overall, this study indicated that the O-MAR function can remarkably reduce metal artifacts and improve both CT Hounsfield number accuracy and target and critical structure visualization. Although there was no significant impact of the O-MAR algorithm on the calculated dose distributions, we suggest that O-MAR corrected images are more suitable for the entire treatment planning process by offering better anatomical structure visualization, improving radiation oncologists’ confidence in target delineation, and by avoiding subjective density overrides of artifact regions on uncorrected images. PMID:23231300