2017-01-01
Synchronization of population dynamics in different habitats is a frequently observed phenomenon. A common mathematical tool to reveal synchronization is the (cross)correlation coefficient between time courses of values of the population size of a given species where the population size is evaluated from spatial sampling data. The corresponding sampling net or grid is often coarse, i.e. it does not resolve all details of the spatial configuration, and the evaluation error—i.e. the difference between the true value of the population size and its estimated value—can be considerable. We show that this estimation error can make the value of the correlation coefficient very inaccurate or even irrelevant. We consider several population models to show that the value of the correlation coefficient calculated on a coarse sampling grid rarely exceeds 0.5, even if the true value is close to 1, so that the synchronization is effectively lost. We also observe ‘ghost synchronization’ when the correlation coefficient calculated on a coarse sampling grid is close to 1 but in reality the dynamics are not correlated. Finally, we suggest a simple test to check the sampling grid coarseness and hence to distinguish between the true and artifactual values of the correlation coefficient. PMID:28202589
Estimation of soil-soil solution distribution coefficient of radiostrontium using soil properties.
Ishikawa, Nao K; Uchida, Shigeo; Tagami, Keiko
2009-02-01
We propose a new approach for estimation of soil-soil solution distribution coefficient (K(d)) of radiostrontium using some selected soil properties. We used 142 Japanese agricultural soil samples (35 Andosol, 25 Cambisol, 77 Fluvisol, and 5 others) for which Sr-K(d) values had been determined by a batch sorption test and listed in our database. Spearman's rank correlation test was carried out to investigate correlations between Sr-K(d) values and soil properties. Electrical conductivity and water soluble Ca had good correlations with Sr-K(d) values for all soil groups. Then, we found a high correlation between the ratio of exchangeable Ca to Ca concentration in water soluble fraction and Sr-K(d) values with correlation coefficient R=0.72. This pointed us toward a relatively easy way to estimate Sr-K(d) values.
Empirical correlations for axial dispersion coefficient and Peclet number in fixed-bed columns.
Rastegar, Seyed Omid; Gu, Tingyue
2017-03-24
In this work, a new correlation for the axial dispersion coefficient was obtained using experimental data in the literature for axial dispersion in fixed-bed columns packed with particles. The Chung and Wen correlation, the De Ligny correlation are two popular empirical correlations. However, the former lacks the molecular diffusion term and the latter does not consider bed voidage. The new axial dispersion coefficient correlation in this work was based on additional experimental data in the literature by considering both molecular diffusion and bed voidage. It is more comprehensive and accurate. The Peclet number correlation from the new axial dispersion coefficient correlation on the average leads to 12% lower Peclet number values compared to the values from the Chung and Wen correlation, and in many cases much smaller than those from the De Ligny correlation. Copyright © 2017 Elsevier B.V. All rights reserved.
Clustering Coefficients for Correlation Networks.
Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu
2018-01-01
Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties.
Clustering Coefficients for Correlation Networks
Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu
2018-01-01
Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties. PMID:29599714
Pal, Shyamali
2017-12-01
The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.
Evaluation of generalized heat-transfer coefficients in pilot AFBC units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grewal, N.S.
Experimental data for heat transfer rates as obtained in a 0.209m/sup 2/ AFBC unit at the GFETC is examined in the light of the existing four correlations for heat transfer coefficient between an immersed staggered array of horizontal tubes and a gas-solid fluidized bed. The predicted values of heat transfer coefficient from the correlations proposed by Grewal and Bansal are found to be in good agreement with the experimental values of heat transfer coefficient when the contribution due to radiation is also included.
Evaluation of generalized heat transfer coefficients in pilot AFBC units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grewal, N.S.
Experimental data for heat transfer rates as obtained in a 0.209m/sup 2/ AFBC unit at the GFETC is examined in the light of the existing four correlations for heat transfer coefficient between an immersed staggered array of horizontal tubes and a gas-solid fluidized bed. The predicted values of heat transfer coefficient from the correlations proposed by Grewal and Bansal are found to be in good agreement with the experimental values of heat transfer coefficient when the contribution due to radiation is also included.
Modified Regression Correlation Coefficient for Poisson Regression Model
NASA Astrophysics Data System (ADS)
Kaengthong, Nattacha; Domthong, Uthumporn
2017-09-01
This study gives attention to indicators in predictive power of the Generalized Linear Model (GLM) which are widely used; however, often having some restrictions. We are interested in regression correlation coefficient for a Poisson regression model. This is a measure of predictive power, and defined by the relationship between the dependent variable (Y) and the expected value of the dependent variable given the independent variables [E(Y|X)] for the Poisson regression model. The dependent variable is distributed as Poisson. The purpose of this research was modifying regression correlation coefficient for Poisson regression model. We also compare the proposed modified regression correlation coefficient with the traditional regression correlation coefficient in the case of two or more independent variables, and having multicollinearity in independent variables. The result shows that the proposed regression correlation coefficient is better than the traditional regression correlation coefficient based on Bias and the Root Mean Square Error (RMSE).
Sakakibara, Ryota; Kitahara, Mizuho
2016-06-01
This study aimed to investigate the relations between CERQ and depression, and anxiety and also aimed to reveal the characteristics of a Japanese sample through meta-analysis. The results showed that self-blame, acceptance, rumination, catastrophizing, and blaming others had significantly positive correlations with both depression and anxiety, whereas positive refocusing, refocus on planning, positive reappraisal, and putting into perspective had significantly negative correlations with both variables. Moreover, when comparing the correlation coefficients of the Japanese samples and the combined value, correlations between depression and positive reappraisal were significantly larger than the combined value. On the other hand, regarding the correlation coefficients of depression and putting into perspective, the combined value was larger than the value of Japanese samples. In addition, compared to the combined value, the Japanese sample's positive correlation between anxiety and rumination, and negative correlation between anxiety and positive reappraisal were larger.
ERIC Educational Resources Information Center
Korendijk, Elly J. H.; Moerbeek, Mirjam; Maas, Cora J. M.
2010-01-01
In the case of trials with nested data, the optimal allocation of units depends on the budget, the costs, and the intracluster correlation coefficient. In general, the intracluster correlation coefficient is unknown in advance and an initial guess has to be made based on published values or subject matter knowledge. This initial estimate is likely…
Biostatistics Series Module 6: Correlation and Linear Regression.
Hazra, Avijit; Gogtay, Nithya
2016-01-01
Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient ( r ). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r 2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation ( y = a + bx ), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous.
Biostatistics Series Module 6: Correlation and Linear Regression
Hazra, Avijit; Gogtay, Nithya
2016-01-01
Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient (r). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation (y = a + bx), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous. PMID:27904175
Commander and User Perceptions of the Army’s Intransit Visibility (ITV) Architecture
2007-03-01
covariance matrix; (c) Bartlett’s test of Sphericity; and (d) Kaiser-Meyer- Olkin ( KMO ) measure of sampling adequacy. The inter-item correlation matrix...001), and all diagonal terms had a value of 1 while off-diagonal terms were 0. The KMO measure of sampling adequacy reflects the homogeneity...amongst the variables and serves as an index for comparing the magnitudes of correlation coefficients to partial correlation coefficients. KMO values at
Virial Coefficients for the Liquid Argon
NASA Astrophysics Data System (ADS)
Korth, Micheal; Kim, Saesun
2014-03-01
We begin with a geometric model of hard colliding spheres and calculate probability densities in an iterative sequence of calculations that lead to the pair correlation function. The model is based on a kinetic theory approach developed by Shinomoto, to which we added an interatomic potential for argon based on the model from Aziz. From values of the pair correlation function at various values of density, we were able to find viral coefficients of liquid argon. The low order coefficients are in good agreement with theoretical hard sphere coefficients, but appropriate data for argon to which these results might be compared is difficult to find.
Temporal correlation coefficient for directed networks.
Büttner, Kathrin; Salau, Jennifer; Krieter, Joachim
2016-01-01
Previous studies dealing with network theory focused mainly on the static aggregation of edges over specific time window lengths. Thus, most of the dynamic information gets lost. To assess the quality of such a static aggregation the temporal correlation coefficient can be calculated. It measures the overall possibility for an edge to persist between two consecutive snapshots. Up to now, this measure is only defined for undirected networks. Therefore, we introduce the adaption of the temporal correlation coefficient to directed networks. This new methodology enables the distinction between ingoing and outgoing edges. Besides a small example network presenting the single calculation steps, we also calculated the proposed measurements for a real pig trade network to emphasize the importance of considering the edge direction. The farm types at the beginning of the pork supply chain showed clearly higher values for the outgoing temporal correlation coefficient compared to the farm types at the end of the pork supply chain. These farm types showed higher values for the ingoing temporal correlation coefficient. The temporal correlation coefficient is a valuable tool to understand the structural dynamics of these systems, as it assesses the consistency of the edge configuration. The adaption of this measure for directed networks may help to preserve meaningful additional information about the investigated network that might get lost if the edge directions are ignored.
Barlow, Andrew L; Macleod, Alasdair; Noppen, Samuel; Sanderson, Jeremy; Guérin, Christopher J
2010-12-01
One of the most routine uses of fluorescence microscopy is colocalization, i.e., the demonstration of a relationship between pairs of biological molecules. Frequently this is presented simplistically by the use of overlays of red and green images, with areas of yellow indicating colocalization of the molecules. Colocalization data are rarely quantified and can be misleading. Our results from both synthetic and biological datasets demonstrate that the generation of Pearson's correlation coefficient between pairs of images can overestimate positive correlation and fail to demonstrate negative correlation. We have demonstrated that the calculation of a thresholded Pearson's correlation coefficient using only intensity values over a determined threshold in both channels produces numerical values that more accurately describe both synthetic datasets and biological examples. Its use will bring clarity and accuracy to colocalization studies using fluorescent microscopy.
Ogata, Koji; Hatakeyama, Makoto; Nakamura, Shinichiro
2018-02-15
The octanol-water partition coefficient (log P ow ) is an important index for measuring solubility, membrane permeability, and bioavailability in the drug discovery field. In this paper, the log P ow values of 58 compounds were predicted by alchemical free energy calculation using molecular dynamics simulation. In free energy calculations, the atomic charges of the compounds are always fixed. However, they must be recalculated for each solvent. Therefore, three different sets of atomic charges were tested using quantum chemical calculations, taking into account vacuum, octanol, and water environments. The calculated atomic charges in the different environments do not necessarily influence the correlation between calculated and experimentally measured ∆ G water values. The largest correlation coefficient values of the solvation free energy in water and octanol were 0.93 and 0.90, respectively. On the other hand, the correlation coefficient of log P ow values calculated from free energies, the largest of which was 0.92, was sensitive to the combination of the solvation free energies calculated from the calculated atomic charges. These results reveal that the solvent assumed in the atomic charge calculation is an important factor determining the accuracy of predicted log P ow values.
Python Waveform Cross-Correlation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Templeton, Dennise
PyWCC is a tool to compute seismic waveform cross-correlation coefficients on single-component or multiple-component seismic data across a network of seismic sensors. PyWCC compares waveform data templates with continuous seismic data, associates the resulting detections, identifies the template with the highest cross-correlation coefficient, and outputs a catalog of detections above a user-defined absolute cross-correlation threshold value.
Deng, Shengming; Wu, Zhifang; Wu, Yiwei; Zhang, Wei; Li, Jihui; Dai, Na
2017-01-01
The objective of this meta-analysis is to explore the correlation between the apparent diffusion coefficient (ADC) on diffusion-weighted MR and the standard uptake value (SUV) of 18F-FDG on PET/CT in patients with cancer. Databases such as PubMed (MEDLINE included), EMBASE, and Cochrane Database of Systematic Review were searched for relevant original articles that explored the correlation between SUV and ADC in English. After applying Fisher's r-to-z transformation, correlation coefficient (r) values were extracted from each study and 95% confidence intervals (CIs) were calculated. Sensitivity and subgroup analyses based on tumor type were performed to investigate the potential heterogeneity. Forty-nine studies were eligible for the meta-analysis, comprising 1927 patients. Pooled r for all studies was −0.35 (95% CI: −0.42–0.28) and exhibited a notable heterogeneity (I2 = 78.4%; P < 0.01). In terms of the cancer type subgroup analysis, combined correlation coefficients of ADC/SUV range from −0.12 (lymphoma, n = 5) to −0.59 (pancreatic cancer, n = 2). We concluded that there is an average negative correlation between ADC and SUV in patients with cancer. Higher correlations were found in the brain tumor, cervix carcinoma, and pancreas cancer. However, a larger, prospective study is warranted to validate these findings in different cancer types. PMID:29097924
Deng, Shengming; Wu, Zhifang; Wu, Yiwei; Zhang, Wei; Li, Jihui; Dai, Na; Zhang, Bin; Yan, Jianhua
2017-01-01
The objective of this meta-analysis is to explore the correlation between the apparent diffusion coefficient (ADC) on diffusion-weighted MR and the standard uptake value (SUV) of 18 F-FDG on PET/CT in patients with cancer. Databases such as PubMed (MEDLINE included), EMBASE, and Cochrane Database of Systematic Review were searched for relevant original articles that explored the correlation between SUV and ADC in English. After applying Fisher's r -to- z transformation, correlation coefficient ( r ) values were extracted from each study and 95% confidence intervals (CIs) were calculated. Sensitivity and subgroup analyses based on tumor type were performed to investigate the potential heterogeneity. Forty-nine studies were eligible for the meta-analysis, comprising 1927 patients. Pooled r for all studies was -0.35 (95% CI: -0.42-0.28) and exhibited a notable heterogeneity ( I 2 = 78.4%; P < 0.01). In terms of the cancer type subgroup analysis, combined correlation coefficients of ADC/SUV range from -0.12 (lymphoma, n = 5) to -0.59 (pancreatic cancer, n = 2). We concluded that there is an average negative correlation between ADC and SUV in patients with cancer. Higher correlations were found in the brain tumor, cervix carcinoma, and pancreas cancer. However, a larger, prospective study is warranted to validate these findings in different cancer types.
Zhang, Juping; Yang, Chan; Jin, Zhen; Li, Jia
2018-07-14
In this paper, the correlation coefficients between nodes in states are used as dynamic variables, and we construct SIR epidemic dynamic models with correlation coefficients by using the pair approximation method in static networks and dynamic networks, respectively. Considering the clustering coefficient of the network, we analytically investigate the existence and the local asymptotic stability of each equilibrium of these models and derive threshold values for the prevalence of diseases. Additionally, we obtain two equivalent epidemic thresholds in dynamic networks, which are compared with the results of the mean field equations. Copyright © 2018 Elsevier Ltd. All rights reserved.
Nakatsuka, Haruo; Chiba, Keiko; Watanabe, Takao; Sawatari, Hideyuki; Seki, Takako
2016-11-01
Iodine intake by adults in farming districts in Northeastern Japan was evaluated by two methods: (1) government-approved food composition tables based calculation and (2) instrumental measurement. The correlation between these two values and a regression model for the calibration of calculated values was presented. Iodine intake was calculated, using the values in the Japan Standard Tables of Food Composition (FCT), through the analysis of duplicate samples of complete 24-h food consumption for 90 adult subjects. In cases where the value for iodine content was not available in the FCT, it was assumed to be zero for that food item (calculated values). Iodine content was also measured by ICP-MS (measured values). Calculated and measured values rendered geometric means (GM) of 336 and 279 μg/day, respectively. There was no statistically significant (p > 0.05) difference between calculated and measured values. The correlation coefficient was 0.646 (p < 0.05). With this high correlation coefficient, a simple regression line can be applied to estimate measured value from calculated value. A survey of the literature suggests that the values in this study were similar to values that have been reported to date for Japan, and higher than those for other countries in Asia. Iodine intake of Japanese adults was 336 μg/day (GM, calculated) and 279 μg/day (GM, measured). Both values correlated so well, with a correlation coefficient of 0.646, that a regression model (Y = 130.8 + 1.9479X, where X and Y are measured and calculated values, respectively) could be used to calibrate calculated values.
Toropov, Andrey A; Toropova, Alla P; Raska, Ivan; Benfenati, Emilio
2010-04-01
Three different splits into the subtraining set (n = 22), the set of calibration (n = 21), and the test set (n = 12) of 55 antineoplastic agents have been examined. By the correlation balance of SMILES-based optimal descriptors quite satisfactory models for the octanol/water partition coefficient have been obtained on all three splits. The correlation balance is the optimization of a one-variable model with a target function that provides both the maximal values of the correlation coefficient for the subtraining and calibration set and the minimum of the difference between the above-mentioned correlation coefficients. Thus, the calibration set is a preliminary test set. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.
Pulmonary Catherization Data Correlate Poorly with Renal Function in Heart Failure.
Masha, Luke; Stone, James; Stone, Danielle; Zhang, Jun; Sheng, Luo
2018-04-10
The mechanisms of renal dysfunction in heart failure are poorly understood. We chose to explore the relationship of cardiac filling pressures and cardiac index (CI) in relation to renal dysfunction in advanced heart failure. To determine the relationship between renal function and cardiac filling pressures using the United Network of Organ Sharing (UNOS) pulmonary artery catherization registry. Patients over the age of 18 years who were listed for single-organ heart transplantation were included. Exclusion criteria included a history of mechanical circulatory support, previous transplantation, any use of renal replacement therapy, prior history of malignancy, and cardiac surgery, amongst others. Correlations between serum creatinine (SCr) and CI, pulmonary capillary wedge pressure (PCWP), pulmonary artery systolic pressure (PASP), and pulmonary artery diastolic pressure (PADP) were assessed by Pearson correlation coefficients and simple linear regression coefficients. Pearson correlation coefficients between SCr and PCWP, PASP, and PADP were near zero with values of 0.1, 0.07, and 0.08, respectively (p < 0.0001). A weak negative correlation coefficient between SCr and CI was found (correlation coefficient, -0.045, p = 0.027). In a subgroup of young patients unlikely to have noncardiac etiologies, no significant correlations between these values were identified. These findings suggest that, as assessed by pulmonary artery catherization, none of the factors - PCWP, PASP, PADP, or CI - play a prominent role in cardiorenal syndromes. © 2018 S. Karger AG, Basel.
Ma, Wanling; Li, Na; Zhao, Weiwei; Ren, Jing; Wei, Mengqi; Yang, Yong; Wang, Yingmei; Fu, Xin; Zhang, Zhuoli; Larson, Andrew C; Huan, Yi
2016-01-01
To clarify diffusion and perfusion abnormalities and evaluate correlation between apparent diffusion coefficient (ADC), MR perfusion and histopathologic parameters of pancreatic cancer (PC). Eighteen patients with PC underwent diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Parameters of DCE-MRI and ADC of cancer and non-cancerous tissue were compared. Correlation between the rate constant that represents transfer of contrast agent from the arterial blood into the extravascular extracellular space (K, volume of the extravascular extracellular space per unit volume of tissue (Ve), and ADC of PC and histopathologic parameters were analyzed. The rate constant that represents transfer of contrast agent from the extravascular extracellular space into blood plasma, K, tissue volume fraction occupied by vascular space, and ADC of PC were significantly lower than nontumoral pancreases. Ve of PC was significantly higher than that of nontumoral pancreas. Apparent diffusion coefficient and K values of PC were negatively correlated to fibrosis content and fibroblast activation protein staining score. Fibrosis content was positively correlated to Ve. Apparent diffusion coefficient values and parameters of DCE-MRI can differentiate PC from nontumoral pancreases. There are correlations between ADC, K, Ve, and fibrosis content of PC. Fibroblast activation protein staining score of PC is negatively correlated to ADC and K. Apparent diffusion coefficient, K, and Ve may be feasible to predict prognosis of PC.
Cumulative query method for influenza surveillance using search engine data.
Seo, Dong-Woo; Jo, Min-Woo; Sohn, Chang Hwan; Shin, Soo-Yong; Lee, JaeHo; Yu, Maengsoo; Kim, Won Young; Lim, Kyoung Soo; Lee, Sang-Il
2014-12-16
Internet search queries have become an important data source in syndromic surveillance system. However, there is currently no syndromic surveillance system using Internet search query data in South Korea. The objective of this study was to examine correlations between our cumulative query method and national influenza surveillance data. Our study was based on the local search engine, Daum (approximately 25% market share), and influenza-like illness (ILI) data from the Korea Centers for Disease Control and Prevention. A quota sampling survey was conducted with 200 participants to obtain popular queries. We divided the study period into two sets: Set 1 (the 2009/10 epidemiological year for development set 1 and 2010/11 for validation set 1) and Set 2 (2010/11 for development Set 2 and 2011/12 for validation Set 2). Pearson's correlation coefficients were calculated between the Daum data and the ILI data for the development set. We selected the combined queries for which the correlation coefficients were .7 or higher and listed them in descending order. Then, we created a cumulative query method n representing the number of cumulative combined queries in descending order of the correlation coefficient. In validation set 1, 13 cumulative query methods were applied, and 8 had higher correlation coefficients (min=.916, max=.943) than that of the highest single combined query. Further, 11 of 13 cumulative query methods had an r value of ≥.7, but 4 of 13 combined queries had an r value of ≥.7. In validation set 2, 8 of 15 cumulative query methods showed higher correlation coefficients (min=.975, max=.987) than that of the highest single combined query. All 15 cumulative query methods had an r value of ≥.7, but 6 of 15 combined queries had an r value of ≥.7. Cumulative query method showed relatively higher correlation with national influenza surveillance data than combined queries in the development and validation set.
Threshold network of a financial market using the P-value of correlation coefficients
NASA Astrophysics Data System (ADS)
Ha, Gyeong-Gyun; Lee, Jae Woo; Nobi, Ashadun
2015-06-01
Threshold methods in financial networks are important tools for obtaining important information about the financial state of a market. Previously, absolute thresholds of correlation coefficients have been used; however, they have no relation to the length of time. We assign a threshold value depending on the size of the time window by using the P-value concept of statistics. We construct a threshold network (TN) at the same threshold value for two different time window sizes in the Korean Composite Stock Price Index (KOSPI). We measure network properties, such as the edge density, clustering coefficient, assortativity coefficient, and modularity. We determine that a significant difference exists between the network properties of the two time windows at the same threshold, especially during crises. This implies that the market information depends on the length of the time window when constructing the TN. We apply the same technique to Standard and Poor's 500 (S&P500) and observe similar results.
Miyamoto, Shuichi; Atsuyama, Kenji; Ekino, Keisuke; Shin, Takashi
2018-01-01
The isolation of useful microbes is one of the traditional approaches for the lead generation in drug discovery. As an effective technique for microbe isolation, we recently developed a multidimensional diffusion-based gradient culture system of microbes. In order to enhance the utility of the system, it is favorable to have diffusion coefficients of nutrients such as sugars in the culture medium beforehand. We have, therefore, built a simple and convenient experimental system that uses agar-gel to observe diffusion. Next, we performed computer simulations-based on random-walk concepts-of the experimental diffusion system and derived correlation formulas that relate observable diffusion data to diffusion coefficients. Finally, we applied these correlation formulas to our experimentally-determined diffusion data to estimate the diffusion coefficients of sugars. Our values for these coefficients agree reasonably well with values published in the literature. The effectiveness of our simple technique, which has elucidated the diffusion coefficients of some molecules which are rarely reported (e.g., galactose, trehalose, and glycerol) is demonstrated by the strong correspondence between the literature values and those obtained in our experiments.
Distance correlation methods for discovering associations in large astrophysical databases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martínez-Gómez, Elizabeth; Richards, Mercedes T.; Richards, Donald St. P., E-mail: elizabeth.martinez@itam.mx, E-mail: mrichards@astro.psu.edu, E-mail: richards@stat.psu.edu
2014-01-20
High-dimensional, large-sample astrophysical databases of galaxy clusters, such as the Chandra Deep Field South COMBO-17 database, provide measurements on many variables for thousands of galaxies and a range of redshifts. Current understanding of galaxy formation and evolution rests sensitively on relationships between different astrophysical variables; hence an ability to detect and verify associations or correlations between variables is important in astrophysical research. In this paper, we apply a recently defined statistical measure called the distance correlation coefficient, which can be used to identify new associations and correlations between astrophysical variables. The distance correlation coefficient applies to variables of any dimension,more » can be used to determine smaller sets of variables that provide equivalent astrophysical information, is zero only when variables are independent, and is capable of detecting nonlinear associations that are undetectable by the classical Pearson correlation coefficient. Hence, the distance correlation coefficient provides more information than the Pearson coefficient. We analyze numerous pairs of variables in the COMBO-17 database with the distance correlation method and with the maximal information coefficient. We show that the Pearson coefficient can be estimated with higher accuracy from the corresponding distance correlation coefficient than from the maximal information coefficient. For given values of the Pearson coefficient, the distance correlation method has a greater ability than the maximal information coefficient to resolve astrophysical data into highly concentrated horseshoe- or V-shapes, which enhances classification and pattern identification. These results are observed over a range of redshifts beyond the local universe and for galaxies from elliptical to spiral.« less
Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P
2016-04-01
Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.
Łojewski, Tomasz; Zieba, Katarzyna; Lojewska, Joanna
2010-10-15
The paper deals with the application of size exclusion chromatography (SEC) for the studies of paper degradation phenomena. The goal is to solve some of the technical problems connected with the calibration of multi-detector SEC system and to find the correlation between SEC and viscometric results of degree of polymerization of cellulose. The results gathered for the paper samples degraded by acidic air pollutant (NO(2)) are used as an example of SEC-MALLS application. From the correlation between intrinsic viscosities and absolute value of molecular masses obtained with SEC/MALLS (Multi Angle Laser Light Scattering) technique, Mark-Houwink coefficients for cellulose in cupri-ethylenediamine solution were determined. Thus obtained coefficients were used for the determination of viscometric degree of polymerization (molecular mass) of the aged samples. An excellent correlation was found between the chromatographic values of molecular masses obtained with SEC-UV/VIS detection and the viscometric ones utilizing the improved values of Mark-Houwink coefficients. Copyright © 2010 Elsevier B.V. All rights reserved.
Zhao, Yang; Zhang, Xue Qing; Bian, Xiao Dong
2018-01-01
To investigate the early supplementary processes of fishre sources in the Bohai Sea, the geographically weighted regression (GWR) was introduced to the habitat suitability index (HSI) model. The Bohai Sea larval Japanese Halfbeak HSI GWR model was established with four environmental variables, including sea surface temperature (SST), sea surface salinity (SSS), water depth (DEP), and chlorophyll a concentration (Chl a). Results of the simulation showed that the four variables had different performances in August 2015. SST and Chl a were global variables, and had little impacts on HSI, with the regression coefficients of -0.027 and 0.006, respectively. SSS and DEP were local variables, and had larger impacts on HSI, while the average values of absolute values of their regression coefficients were 0.075 and 0.129, respectively. In the central Bohai Sea, SSS showed a negative correlation with HSI, and the most negative correlation coefficient was -0.3. In contrast, SSS was correlated positively but weakly with HSI in the three bays of Bohai Sea, and the largest correlation coefficient was 0.1. In particular, DEP and HSI were negatively correlated in the entire Bohai Sea, while they were more negatively correlated in the three bays of Bohai than in the central Bohai Sea, and the most negative correlation coefficient was -0.16 in the three bays. The Poisson regression coefficient of the HSI GWR model was 0.705, consistent with field measurements. Therefore, it could provide a new method for the research on fish habitats in the future.
Turbulence in a gaseous hydrogen-liquid oxygen rocket combustion chamber
NASA Technical Reports Server (NTRS)
Lebas, J.; Tou, P.; Ohara, J.
1975-01-01
The intensity of turbulence and the Lagrangian correlation coefficient for a LOX-GH2 rocket combustion chamber was determined from experimental measurements of tracer gas diffusion. A combination of Taylor's turbulent diffusion theory and a numerical method for solving the conservation equations of fluid mechanics was used to calculate these quantities. Taylor's theory was extended to consider the inhomogeneity of the turbulence field in the axial direction of the combustion chamber, and an exponential function was used to represent the Lagrangian correlation coefficient. The results indicate that the value of the intensity of turbulence reaches a maximum of 14% at a location about 7" downstream from the injector. The Lagrangian correlation coefficient associated with this value is given by the above exponential expression where alpha = 10,000/sec.
Lowery, Michael G; Calfin, Brenda; Yeh, Shu-Jen; Doan, Tao; Shain, Eric; Hanna, Charles; Hohs, Ronald; Kantor, Stan; Lindberg, John; Khalil, Omar S
2006-01-01
We used the effect of temperature on the localized reflectance of human skin to assess the role of noise sources on the correlation between temperature-induced fractional change in optical density of human skin (DeltaOD(T)) and blood glucose concentration [BG]. Two temperature-controlled optical probes at 30 degrees C contacted the skin, one was then cooled by -10 degrees C; the other was heated by +10 degrees C. DeltaOD(T) upon cooling or heating was correlated with capillary [BG] of diabetic volunteers over a period of three days. Calibration models in the first two days were used to predict [BG] in the third day. We examined the conditions where the correlation coefficient (R2) for predicting [BG] in a third day ranked higher than R2 values resulting from fitting permutations of randomized [BG] to the same DeltaOD(T) values. It was possible to establish a four-term linear regression correlation between DeltaOD(T) upon cooling and [BG] with a correlation coefficient higher than that of an established noise threshold in diabetic patients that were mostly females with less than 20 years of diabetes duration. The ability to predict [BG] values with a correlation coefficient above biological and body-interface noise varied between the cases of cooling and heating.
Genome-scale cluster analysis of replicated microarrays using shrinkage correlation coefficient.
Yao, Jianchao; Chang, Chunqi; Salmi, Mari L; Hung, Yeung Sam; Loraine, Ann; Roux, Stanley J
2008-06-18
Currently, clustering with some form of correlation coefficient as the gene similarity metric has become a popular method for profiling genomic data. The Pearson correlation coefficient and the standard deviation (SD)-weighted correlation coefficient are the two most widely-used correlations as the similarity metrics in clustering microarray data. However, these two correlations are not optimal for analyzing replicated microarray data generated by most laboratories. An effective correlation coefficient is needed to provide statistically sufficient analysis of replicated microarray data. In this study, we describe a novel correlation coefficient, shrinkage correlation coefficient (SCC), that fully exploits the similarity between the replicated microarray experimental samples. The methodology considers both the number of replicates and the variance within each experimental group in clustering expression data, and provides a robust statistical estimation of the error of replicated microarray data. The value of SCC is revealed by its comparison with two other correlation coefficients that are currently the most widely-used (Pearson correlation coefficient and SD-weighted correlation coefficient) using statistical measures on both synthetic expression data as well as real gene expression data from Saccharomyces cerevisiae. Two leading clustering methods, hierarchical and k-means clustering were applied for the comparison. The comparison indicated that using SCC achieves better clustering performance. Applying SCC-based hierarchical clustering to the replicated microarray data obtained from germinating spores of the fern Ceratopteris richardii, we discovered two clusters of genes with shared expression patterns during spore germination. Functional analysis suggested that some of the genetic mechanisms that control germination in such diverse plant lineages as mosses and angiosperms are also conserved among ferns. This study shows that SCC is an alternative to the Pearson correlation coefficient and the SD-weighted correlation coefficient, and is particularly useful for clustering replicated microarray data. This computational approach should be generally useful for proteomic data or other high-throughput analysis methodology.
NASA Astrophysics Data System (ADS)
Hu, Jing; Li, Chenxiao; Wen, Yifang; Gao, Xinhao; Shi, Feifei; Han, Luhua
2018-01-01
To determine the best leaf position for nitrogen diagnosis in cucumber with SPAD meter, greenhouse experiments were carried out to study spatial distribution of SPAD value of different position of the 3rd fully expanded cucumber leaf in the effect of different nitrogen levels, and the correlations between SPAD values and nitrogen concentration of chlorophyll. The results show that there is remarkable different SPAD value in different positions of the 3rd fully expanded leaf in the flowering and fruiting stage. Comparing the coefficients of SPAD value variation, we find that the coefficient of variation of leaf edge was significantly higher than the edge of the main vein, and the coefficient of variation of triangular area of leaf tip is significantly higher than any other leaf area. There is a significant correlation between SPAD values and leaf nitrogen content. Preliminary study shows that triangular area of leaf tip from the 20% leaf tip to leaf edge is the best position for nitrogen diagnosis.
Experimental determination of the turbulence in a liquid rocket combustion chamber
NASA Technical Reports Server (NTRS)
Hara, J.; Smith, L. O.; Partus, F. P.
1972-01-01
The intensity of turbulence and the Lagrangian correlation coefficient for a liquid rocket combustion chamber were determined experimentally using the tracer gas diffusion method. The results indicate that the turbulent diffusion process can be adequately modeled by the one-dimensional Taylor theory; however, the numerical values show significant disagreement with previously accepted values. The intensity of turbulence is higher by a factor of about two, while the Lagrangian correlation coefficient which was assumed to be unity in the past is much less than unity.
Li, Dapeng; Yue, Jiawei; Jiang, Lu; Huang, Yonghui; Sun, Jifu; Wu, Yan
2017-04-22
BACKGROUND Degrading enzymes play an important role in the process of disc degeneration. The objective of this study was to investigate the correlation between the expression of high temperature requirement serine protease A1 (HtrA1) in the nucleus pulposus and the T2 value of the nucleus pulposus region in magnetic resonance imaging (MRI). MATERIAL AND METHODS Thirty-six patients who had undergone surgical excision of the nucleus pulposus were examined by MRI before surgery. Pfirrmann grading of the target intervertebral disc was performed according to the sagittal T2-weighted imaging, and the T2 value of the target nucleus pulposus was measured according to the median sagittal T2 mapping. The correlation between the Pfirrmann grade and the T2 value was analyzed. The expression of HtrA1 in the nucleus pulposus was analyzed by RT-PCR and Western blot. The correlation between the expression of HtrA1 and the T2 value was analyzed. RESULTS The T2 value of the nucleus pulposus region was 33.11-167.91 ms, with an average of 86.64±38.73 ms. According to Spearman correlation analysis, there was a rank correlation between T2 value and Pfirrmann grade (P<0.0001), and the correlation coefficient (rs)=-0.93617. There was a linear correlation between the mRNA level of HtrA1 and T2 value in nucleus pulposus tissues (a=3.88, b=-0.019, F=112.63, P<0.0001), normalized regression coefficient=-0.88. There was a linear correlation between the expression level of HtrA1 protein and the T2 value in the nucleus pulposus tissues (a=3.30, b=-0.016, F=93.15, P<0.0001) and normalized regression coefficient=-0.86. CONCLUSIONS The expression of HtrA1 was strongly related to the T2 value, suggesting that HtrA1 plays an important role in the pathological process of intervertebral disc degeneration.
Wang, Yi; Xiang, Ma; Wen, Ya-Dong; Yu, Chun-Xia; Wang, Luo-Ping; Zhao, Long-Lian; Li, Jun-Hui
2012-11-01
In this study, tobacco quality analysis of main Industrial classification of different years was carried out applying spectrum projection and correlation methods. The group of data was near-infrared (NIR) spectrum from Hongta Tobacco (Group) Co., Ltd. 5730 tobacco leaf Industrial classification samples from Yuxi in Yunnan province from 2007 to 2010 year were collected using near infrared spectroscopy, which from different parts and colors and all belong to tobacco varieties of HONGDA. The conclusion showed that, when the samples were divided to two part by the ratio of 2:1 randomly as analysis and verification sets in the same year, the verification set corresponded with the analysis set applying spectrum projection because their correlation coefficients were above 0.98. The correlation coefficients between two different years applying spectrum projection were above 0.97. The highest correlation coefficient was the one between 2008 and 2009 year and the lowest correlation coefficient was the one between 2007 and 2010 year. At the same time, The study discussed a method to get the quantitative similarity values of different industrial classification samples. The similarity and consistency values were instructive in combination and replacement of tobacco leaf blending.
Grueneisen, Johannes; Beiderwellen, Karsten; Heusch, Philipp; Buderath, Paul; Aktas, Bahriye; Gratz, Marcel; Forsting, Michael; Lauenstein, Thomas; Ruhlmann, Verena; Umutlu, Lale
2014-01-01
To evaluate a potential correlation of the maximum standard uptake value (SUVmax) and the minimum apparent diffusion coefficient (ADCmin) in primary and recurrent cervical cancer based on integrated PET/MRI examinations. 19 consecutive patients (mean age 51.6 years; range 30-72 years) with histopathologically confirmed primary cervical cancer (n = 9) or suspected tumor recurrence (n = 10) were prospectively enrolled for an integrated PET/MRI examination. Two radiologists performed a consensus reading in random order, using a dedicated post-processing software. Polygonal regions of interest (ROI) covering the entire tumor lesions were drawn into PET/MR images to assess SUVmax and into ADC parameter maps to determine ADCmin values. Pearson's correlation coefficients were calculated to assess a potential correlation between the mean values of ADCmin and SUVmax. In 15 out of 19 patients cervical cancer lesions (n = 12) or lymph node metastases (n = 42) were detected. Mean SUVmax (12.5 ± 6.5) and ADCmin (644.5 ± 179.7 × 10(-5) mm2/s) values for all assessed tumor lesions showed a significant but weak inverse correlation (R = -0.342, p < 0.05). When subdivided in primary and recurrent tumors, primary tumors and associated primary lymph node metastases revealed a significant and strong inverse correlation between SUVmax and ADCmin (R = -0.692, p < 0.001), whereas recurrent cancer lesions did not show a significant correlation. These initial results of this emerging hybrid imaging technique demonstrate the high diagnostic potential of simultaneous PET/MR imaging for the assessment of functional biomarkers, revealing a significant and strong correlation of tumor metabolism and higher cellularity in cervical cancer lesions.
Persona, Marek; Kutarov, Vladimir V; Kats, Boris M; Persona, Andrzej; Marczewska, Barbara
2007-01-01
The paper describes the new prediction method of octanol-water partition coefficient, which is based on molecular graph theory. The results obtained using the new method are well correlated with experimental values. These results were compared with the ones obtained by use of ten other structure correlated methods. The comparison shows that graph theory can be very useful in structure correlation research.
Sasaki, Satoshi; Ishihara, Junko; Tsugane, Shoichiro
2003-01-01
We compared the intake levels of sodium and potassium assessed with a self-administered semi-quantitative food frequency questionnaire (FFQ) used in a 5-year follow-up survey of the JPHC study and 28-day dietary record (DR), and the corresponding two 24-hour urinary excretion levels (32 men and 57 women) in 3-areas, i.e., Ninohe, Yokote, and Saku Public Health Center areas. The Spearman rank correlation coefficients between dietary sodium assessed with FFQ and the urinary excretion for crude values were 0.24 and -0.10 in men and women, respectively. After adjusting for energy and creatinine, the sodium correlation coefficients were 0.35 and 0.25 in men and women, respectively. The correlation coefficients for crude potassium values were 0.18 and -0.13 in men and women, respectively. After adjusting for energy and creatinine, the potassium correlation coefficients were 0.48 and 0.18 in men and women, respectively in conclusion, a weak correlation was observed both for sodium and potassium after energy and creatinine adjustment in men, whereas no meaningful correlation was observed in women.
Guo, Rongbo; Chen, Jiping; Zhang, Qing; Wu, Wenzhong; Liang, Xinmiao
2004-01-01
Using the methanol-water mixtures as mobile phases of soil column liquid chromatography (SCLC), prediction of soil adsorption coefficients (K(d)) by SCLC was validated in a wide range of soil types. The correlations between the retention factors measured by SCLC and soil adsorption coefficients measured by batch experiments were studied for five soils with different properties, i.e., Eurosoil 1#, 2#, 3#, 4# and 5#. The results show that good correlations existed between the retention factors and soil adsorption coefficients for Eurosoil 1#, 2#, 3# and 4#. For Eurosoil 5# which has a pH value of near 3, the correlation between retention factors and soil adsorption coefficients was unsatisfactory using methanol-water as mobile phase of SCLC. However, a good correlation was obtained using a methanol-buffer mixture with pH 3 as the mobile phase. This study proved that the SCLC is suitable for the prediction of soil adsorption coefficients.
Ryan, William R; Ramachandra, Tara; Hwang, Peter H
2011-03-01
To determine correlations between symptoms, nasal endoscopy findings, and computed tomography (CT) scan findings in post-surgical chronic rhinosinusitis (CRS) patients. Cross-sectional. A total of 51 CRS patients who had undergone endoscopic sinus surgery (ESS) completed symptom questionnaires, underwent endoscopy, and received an in-office sinus CT scan during one clinic visit. For metrics, we used the Sinonasal Outcomes Test-20 (SNOT-20) questionnaire, visual analog symptom scale (VAS), Lund-Kennedy endoscopy scoring scale, and Lund-MacKay (LM) CT scoring scale. We determined Pearson correlation coefficients, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) between scores for symptoms, endoscopy, and CT. The SNOT-20 score and most VAS symptoms had poor correlation coefficients with both endoscopy and CT scores (0.03-0.24). Nasal drainage of pus, nasal congestion, and impaired sense of smell had moderate correlation coefficients with endoscopy and CT (0.24-0.42). Endoscopy had a strong correlation coefficient with CT (0.76). Drainage, edema, and polyps had strong correlation coefficients with CT (0.80, 0.69, and 0.49, respectively). Endoscopy had a PPV of 92.5% and NPV of 45.5% for detecting an abnormal sinus CT (LM score ≥1). In post-ESS CRS patients, most symptoms do not correlate well with either endoscopy or CT findings. Endoscopy and CT scores correlate well. Abnormal endoscopy findings have the ability to confidently rule in the presence of CT opacification, thus validating the importance of endoscopy in clinical decision making. However, a normal endoscopy cannot assure a normal CT. Thus, symptoms, endoscopy, and CT are complementary in the evaluation of the post-ESS CRS patient. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc., Rhinological, and Otological Society, Inc.
Nakajima, Hisato; Yano, Kouya; Nagasawa, Kaoko; Kobayashi, Eiji; Yokota, Kuninobu
2015-01-01
On the basis of Diagnosis Procedure Combination (DPC) survey data, the factors that increase the value of function evaluation coefficient II were considered. A total of 1,505 hospitals were divided into groups I, II, and III, and the following items were considered. 1. Significant differences in function evaluation coefficient II and DPC survey data. 2. Examination of using the Mahalanobis-Taguchi (MT) method. 3. Correlation between function evaluation coefficient II and each DPC survey data item. 1. Function evaluation coefficient II was highest in group II. Group I hospitals showed the highest bed capacity, and numbers of hospitalization days, operations, chemotherapies, radiotherapies and general anesthesia procedures. 2. Using the MT method, we found that the number of ambulance conveyances was effective factor in group I hospitals, the number of general anesthesia procedures was effective factor in group II hospitals, and the bed capacity was effective factor in group III hospitals. 3. In group I hospitals, function evaluation coefficient II significantly correlated to the numbers of ambulance conveyances and chemotherapies. In group II hospitals, function evaluation coefficient II significantly correlated to bed capacity, the numbers of ambulance conveyances, hospitalization days, operations, general anesthesia procedures, and mean hospitalization days. In group III hospitals, function evaluation coefficient II significantly correlated to all items. The factors that improve the value of function evaluation coefficient II were the increases in the numbers of ambulance conveyances, chemotherapies and radiotherapies in group I hospitals, increases in the numbers of hospitalization days, operations, ambulance conveyances and general anesthesia procedures in group II hospitals, and increases in the numbers of hospitalization days, operations and ambulance conveyances. These results indicate that the profit of a hospital will increase, which will lead to medical services of good quality.
NASA Astrophysics Data System (ADS)
Ma, Jing; Fu, Yulong; Tan, Liying; Yu, Siyuan; Xie, Xiaolong
2018-05-01
Spatial diversity as an effective technique to mitigate the turbulence fading has been widely utilized in free space optical (FSO) communication systems. The received signals, however, will suffer from channel correlation due to insufficient spacing between component antennas. In this paper, the new expressions of the channel correlation coefficient and specifically its components (the large- and small-scale channel correlation coefficients) for a plane wave with aperture effects are derived for horizontal link in moderate-to-strong turbulence, using a non-Kolmogorov spectrum that has a generalized power law in the range of 3-4 instead of the fixed classical Kolmogorov power law of 11/3. And then the influence of power law variations on the channel correlation coefficient and its components are analysed. The numerical results indicated that various value of the power law lead to varying effects on the channel correlation coefficient and its components. This work will help with the further investigation on the fading correlation in spatial diversity systems.
NASA Astrophysics Data System (ADS)
Nelson, D. J.
2007-09-01
In the basic correlation process a sequence of time-lag-indexed correlation coefficients are computed as the inner or dot product of segments of two signals. The time-lag(s) for which the magnitude of the correlation coefficient sequence is maximized is the estimated relative time delay of the two signals. For discrete sampled signals, the delay estimated in this manner is quantized with the same relative accuracy as the clock used in sampling the signals. In addition, the correlation coefficients are real if the input signals are real. There have been many methods proposed to estimate signal delay to more accuracy than the sample interval of the digitizer clock, with some success. These methods include interpolation of the correlation coefficients, estimation of the signal delay from the group delay function, and beam forming techniques, such as the MUSIC algorithm. For spectral estimation, techniques based on phase differentiation have been popular, but these techniques have apparently not been applied to the correlation problem . We propose a phase based delay estimation method (PBDEM) based on the phase of the correlation function that provides a significant improvement of the accuracy of time delay estimation. In the process, the standard correlation function is first calculated. A time lag error function is then calculated from the correlation phase and is used to interpolate the correlation function. The signal delay is shown to be accurately estimated as the zero crossing of the correlation phase near the index of the peak correlation magnitude. This process is nearly as fast as the conventional correlation function on which it is based. For real valued signals, a simple modification is provided, which results in the same correlation accuracy as is obtained for complex valued signals.
2004-03-01
reliability coefficients are presented in chapter four in the factor analysis section. Along with Crobach’s Alpha coefficients, the Kaiser - Meyer - Olkin ...the pattern of correlation coefficients > 0.300 in the correlation matrix • Kaiser - Meyer - Olkin Measure of Sampling Adequacy (MSA) > 0.700 • Bartlett’s...exploratory factor analysis. The Kaiser - Meyer - Olkin measure of sampling adequacy yielded a value of .790, and Bartlett’s test of sphericity yielded a
Determination of corneal elasticity coefficient using the ORA database.
Avetisov, Sergei E; Novikov, Ivan A; Bubnova, Irina A; Antonov, Alexei A; Siplivyi, Vladimir I
2010-07-01
To propose a new approach for the study of corneal biomechanics using the Reichert Ocular Response Analyzer (ORA) database, which is based on changes in velocity retardation in the central cornea at the peak of flattening. The ORA applanation curve was analyzed using a mathematical technique, which allowed calculation of the elasticity coefficient (Ke), which is primarily characteristic of the elastic properties of the cornea. Elasticity coefficient values were obtained in patients with presumably different biomechanical properties of the cornea: "normal" cornea (71 eyes, normal group), keratoconus (34 eyes, keratoconus group), LASIK (36 eyes, LASIK group), and glaucoma with elevated and compensated intraocular pressure (lOP) (38 eyes, glaucoma group). The mean Ke value in the normal group was 11.05 +/- 1.6, and the corneal thickness correlation coefficient r2 was 0.48. In the keratoconus group, the mean Ke value was 4.91 +/- 1.87 and the corneal thickness correlation coefficient r2 was 0.47. In the LASIK group, Ke and r2 were 5.99 +/- 1.18 and 0.39, respectively. In the glaucoma group, the same eyes that experienced a two-fold reduction in lOP developed a statistically significant reduction in the Ke (1.06 times lower), whereas their corneal hysteresis value increased 1.25 times. The elasticity coefficient calculated using the ORA applanation curve can be used in the evaluation of corneal biomechanical properties.
Kishimoto, Keiko; Tajima, Shinya; Maeda, Ichiro; Takagi, Masayuki; Ueno, Takahiko; Suzuki, Nao; Nakajima, Yasuo
2016-08-01
Diffusion-weighted imaging (DWI) and the apparent diffusion coefficient (ADC) are widely used for detecting uterine endometrial cancer. The relationships between ADC values and pathological features of endometrial cancer have not yet been established. To investigate whether ADC values of endometrial cancer vary according to histologic tumor cellularity and tumor grade. We retrospectively reviewed 30 pathologically confirmed endometrial cancers. All patients underwent conventional non-enhanced magnetic resonance imaging (MRI) and DWI procedures, and ADC values were calculated. Tumor cellularity was evaluated by counting cancer cells in three high-power ( × 400) fields. The correlation between ADC values and tumor cellularity was assessed using Pearson's correlation coefficient test for statistical analysis. The mean ± standard deviation (SD) ADC value ( ×10(-3) mm(2)/s) of endometrial cancer was 0.85 ± 0.22 (range, 0.55-1.71). The mean ± SD tumor cellularity was 528.36 ± 16.89 (range, 298.0-763.6). ADC values were significantly inversely correlated with tumor cellularity. No significant relationship was observed between ADC values and tumor grade (mean ADC values: G1, 0.88 ± 0.265 × 10(-3) mm(2)/s; G2, 0.80 ± 0.178 × 10(-3) mm(2)/s; G3, 0.81 ± 0.117 × 10(-3) mm(2)/s). There is a significant inverse relationship between ADC values and tumor cellularity in endometrial cancer. No significant differences in average ADC value were observed between G1, G2, and G3 tumors. However, the lower the tumor grade, the wider the SD. © The Foundation Acta Radiologica 2015.
Hwang, Joon Ho; Sohn, Yong-Hak; Chang, Seong-Sil; Kim, Seung Yeon
2015-08-01
We evaluated three blood glucose self-monitoring for measuring whole blood glucose levels in preterm and low-birth-weight infants. Between December 1, 2012 and March 31, 2013, 230 blood samples were collected from 50 newborns, who weighed, ≤2,300 g or were ≤36 weeks old, in the the neonatal intensive care unit of Eulji University Hospital. Three blood glucose self-monitoring (A: Precision Pcx, Abbott; B: One-Touch Verio, Johnson & Johnson; C: LifeScan SureStep Flexx, Johnson & Johnson) were used for the blood glucose measurements. The results were compared to those obtained using laboratory equipment (D: Advia chemical analyzer, Siemens Healthcare Diagnostics Inc.). The correlation coefficients between laboratory equipment and the three blood glucose self-monitoring (A, B, and C) were found to be 0.888, 0.884, and 0.900, respectively. For glucose levels≤60 mg/dL, the correlation coefficients were 0.674, 0.687, and 0.679, respectively. For glucose levels>60 mg/dL, the correlation coefficients were 0.822, 0.819, and 0.839, respectively. All correlation coefficients were statistically significant. And the values from the blood glucose self-monitoring were not significantly different from the value of the laboratory equipment , after correcting for each device's average value (P>0.05). When using laboratory equipment (blood glucose ≤60 mg/dL), each device had a sensitivity of 0.458, 0.604, and 0.688 and a specificity of 0.995, 0.989, and 0.989, respectively. Significant difference is not found between three blood glucose self-monitoring and laboratory equipment. But correlation between the measured values from blood glucose self-monitoring and laboratory equipment is lower in preterm or low-birth-weight infants than adults.
Wang, Jimin; Brudvig, Gary W; Batista, Victor S; Moore, Peter B
2017-12-01
In 2012, Karplus and Diederichs demonstrated that the Pearson correlation coefficient CC 1/2 is a far better indicator of the quality and resolution of crystallographic data sets than more traditional measures like merging R-factor or signal-to-noise ratio. More specifically, they proposed that CC 1/2 be computed for data sets in thin shells of increasing resolution so that the resolution dependence of that quantity can be examined. Recently, however, the CC 1/2 values of entire data sets, i.e., cumulative correlation coefficients, have been used as a measure of data quality. Here, we show that the difference in cumulative CC 1/2 value between a data set that has been accurately measured and a data set that has not is likely to be small. Furthermore, structures obtained by molecular replacement from poorly measured data sets are likely to suffer from extreme model bias. © 2017 The Protein Society.
Nonlinearity of the forward-backward correlation function in the model with string fusion
NASA Astrophysics Data System (ADS)
Vechernin, Vladimir
2017-12-01
The behavior of the forward-backward correlation functions and the corresponding correlation coefficients between multiplicities and transverse momenta of particles produced in high energy hadronic interactions is analyzed by analytical and MC calculations in the models with and without string fusion. The string fusion is taking into account in simplified form by introducing the lattice in the transverse plane. The results obtained with two alternative definitions of the forward-backward correlation coefficient are compared. It is shown that the nonlinearity of correlation functions increases with the width of observation windows, leading at small string density to a strong dependence of correlation coefficient value on the definition. The results of the modeling enable qualitatively to explain the experimentally observed features in the behavior of the correlation functions between multiplicities and mean transverse momenta at small and large multiplicities.
Winter, Karsten; Richter, Cindy; Hoehn, Anna-Kathrin
2018-01-01
Our purpose was to analyze associations between apparent diffusion coefficient (ADC) histogram analysis parameters and histopathologicalfeatures in head and neck squamous cell carcinoma (HNSCC). The study involved 32 patients with primary HNSCC. For every tumor, the following histogram analysis parameters were calculated: ADCmean, ADCmax, ADCmin, ADCmedian, ADCmode, P10, P25, P75, P90, kurtosis, skewness, and entropy. Furthermore, proliferation index KI 67, cell count, total and average nucleic areas were estimated. Spearman's correlation coefficient (p) was used to analyze associations between investigated parameters. In overall sample, all ADC values showed moderate inverse correlations with KI 67. All ADC values except ADCmax correlated inversely with tumor cellularity. Slightly correlations were identified between total/average nucleic area and ADCmean, ADCmin, ADCmedian, and P25. In G1/2 tumors, only ADCmode correlated well with Ki67. No statistically significant correlations between ADC parameters and cellularity were found. In G3 tumors, Ki 67 correlated with all ADC parameters except ADCmode. Cell count correlated well with all ADC parameters except ADCmax. Total nucleic area correlated inversely with ADCmean, ADCmin, ADCmedian, P25, and P90. ADC histogram parameters reflect proliferation potential and cellularity in HNSCC. The associations between histopathology and imaging depend on tumor grading. PMID:29805759
An interrater reliability study of the Braden scale in two nursing homes.
Kottner, Jan; Dassen, Theo
2008-10-01
Adequate risk assessment is essential in pressure ulcer prevention. Assessment scales were designed to support practitioners in identifying persons at pressure ulcer risk. The Braden scale is one of the most extensively studied risk assessment instruments, although the majority of studies focused on validity rather than reliability. The first aim was to measure the interrater reliability of the Braden scale and its individual items. The second aim was to study different statistical approaches regarding interrater reliability estimation. An interrater reliability study was conducted in two German nursing homes. Residents (n = 152) from 8 units were assessed twice. The raters were trained nurses with a work experience ranging from 0.5 to 30 years. Data were analysed using an overall percentage of agreement, weighted and unweighted kappa and the intraclass correlation coefficient. Differences between nurses rating the overall Braden score ranged from 0 up to 9 points. Interrater reliability expressed by the intraclass correlation coefficient ranged from 0.73 (95% CI 0.26 - 0.91) to 0.95 (95% CI 0.87 - 0.98). Calculated intraclass correlation coefficients for individual items ranged from 0.06 (95% CI -0.31 to 0.48) to 0.97 (95% CI 0.93-0.99) with the lowest values being measured for the items "sensory perception" and "nutrition". There was no association between work experience and the level of interrater reliability. With two exceptions, simple kappa-values were always lower than weighted kappa-values and intraclass correlation coefficients. Although the calculated interrater reliability coefficients for the total Braden score were high in some cases, several clinically relevant differences occurred between the nurses. Due to interrater reliability being very low for the items "sensory perception" and "nutrition", it is doubtful if their assessment contributes to any valid results. The calculation of weighted kappa or intraclass correlation coefficients is the most appropriate interrater reliability estimates.
Dynamical behavior of the correlation between meteorological factors
NASA Astrophysics Data System (ADS)
You, Cheol-Hwan; Chang, Ki-Ho; Lee, Jun-Ho; Kim, Kyungsik
2017-12-01
We study the temporal and spatial variation characteristics of meteorological factors (temperature, humidity, and wind velocity) at a meteorological tower located on Bosung-gun of South Korea. We employ the detrended cross-correlation analysis (DCCA) method to extract the overall tendency of the hourly variation from data of meteorological factors. The relationships between meteorological factors are identified and quantified by using DCCA coefficients. From our results, we ascertain that the DCCA coefficient between temperature and humidity at time lag m = 24 has the smallest value at the height of 10 m of the measuring tower. Particularly, the DCCA coefficient between temperature and wind speed at time lag m = 24 has the largest value at a height of 10 m of the measuring tower
Heat transfer to horizontal tubes in a pilot-scale fluidized-bed combustor burning low-rank coals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grewal, N.S.; Goblirsch, G.
Experimental data are obtained for the heat transfer coefficient between immersed horizontal tube bundles and an atmospheric-fluidized-bed combustor burning low-rank coals. Silica sand and limestone are used as bed material. The tests are conducted, with and without limestone addition and ash recycle, at average bed temperatures ranging from 1047 to 1125 K, superficial fluidizing velocity of 1.66 to 2.04 m/s, and excess air levels of 15 to 40 percent. The experimental data are examined in the light of the existing correlations for the heat transfer coefficient. The predicted values of heat transfer coefficient from the correlations proposed by Grewal andmore » Bansal et al. are found to be within + or - 25 percent of the experimental values of heat transfer coefficient, when the contribution due to radiation is also included.« less
Correlation Coefficients: Appropriate Use and Interpretation.
Schober, Patrick; Boer, Christa; Schwarte, Lothar A
2018-05-01
Correlation in the broadest sense is a measure of an association between variables. In correlated data, the change in the magnitude of 1 variable is associated with a change in the magnitude of another variable, either in the same (positive correlation) or in the opposite (negative correlation) direction. Most often, the term correlation is used in the context of a linear relationship between 2 continuous variables and expressed as Pearson product-moment correlation. The Pearson correlation coefficient is typically used for jointly normally distributed data (data that follow a bivariate normal distribution). For nonnormally distributed continuous data, for ordinal data, or for data with relevant outliers, a Spearman rank correlation can be used as a measure of a monotonic association. Both correlation coefficients are scaled such that they range from -1 to +1, where 0 indicates that there is no linear or monotonic association, and the relationship gets stronger and ultimately approaches a straight line (Pearson correlation) or a constantly increasing or decreasing curve (Spearman correlation) as the coefficient approaches an absolute value of 1. Hypothesis tests and confidence intervals can be used to address the statistical significance of the results and to estimate the strength of the relationship in the population from which the data were sampled. The aim of this tutorial is to guide researchers and clinicians in the appropriate use and interpretation of correlation coefficients.
Nkenke, Emeka; Lehner, Bernhard; Kramer, Manuel; Haeusler, Gerd; Benz, Stefanie; Schuster, Maria; Neukam, Friedrich W; Vairaktaris, Eleftherios G; Wurm, Jochen
2006-03-01
To assess measurement errors of a novel technique for the three-dimensional determination of the degree of facial symmetry in patients suffering from unilateral cleft lip and palate malformations. Technical report, reliability study. Cleft Lip and Palate Center of the University of Erlangen-Nuremberg, Erlangen, Germany. The three-dimensional facial surface data of five 10-year-old unilateral cleft lip and palate patients were subjected to the analysis. Distances, angles, surface areas, and volumes were assessed twice. Calculations were made for method error, intraclass correlation coefficient, and repeatability of the measurements of distances, angles, surface areas, and volumes. The method errors were less than 1 mm for distances and less than 1.5 degrees for angles. The intraclass correlation coefficients showed values greater than .90 for all parameters. The repeatability values were comparable for cleft and noncleft sides. The small method errors, high intraclass correlation coefficients, and comparable repeatability values for cleft and noncleft sides reveal that the new technique is appropriate for clinical use.
Shen, Guohua; Ma, Huan; Liu, Bin; Ren, Pengwei; Kuang, Anren
2017-12-01
Diffusion-weighted imaging and fluorine-18-fluorodeoxyglucose PET are increasingly being recognized as feasible oncological techniques. The apparent diffusion coefficient (ADC) measured by diffusion-weighted imaging and the standardized uptake value (SUV) from fluorine-18-fluorodeoxyglucose PET have similar clinical applications. The aim of this study was to assess the correlation between these two parameters in various cancers. Several major databases were searched for eligible studies. The correlation coefficient (ρ) values were pooled in a random-effects model. Begg's test was used to analyze the existence of publication bias and the sources of heterogeneity were explored in subgroup analyses on the basis of study design, diagnostic method, scanning modality, and tumor type. Thirty-five articles were accepted. The pooled ρ value of all of the accepted studies was -0.30 (95% confidence interval: -0.33 to -0.27), and notable heterogeneity was present (I=69.4%, P<0.001), which indicated a relatively weak negative correlation. The pooled ρ values were -0.26, -0.33, -0.32, and -0.33 for the SUVmax/ADCmean, SUVmax/ADCmin, SUVmean/ADCmean, and SUVmean/ADCmin relationships, respectively. The study design and diagnostic method were potential sources of heterogeneity. Lung cancer showed a stronger correlation (ρ=-0.42) than head and neck cancer (ρ=-0.27), cervical cancer (ρ=-0.21), and breast cancer (ρ=-0.23). A Begg's test indicated no significant publication bias among the accepted studies (P>0.05). The two functional parameters of ADC and SUV showed a very weak inverse correlation, which may contribute toward a sophisticated characterization of tumor biology. However, the findings require further validation with trials with large samples and different tumor types.
Usuda, Katsuo; Funasaki, Aika; Sekimura, Atsushi; Motono, Nozomu; Matoba, Munetaka; Doai, Mariko; Yamada, Sohsuke; Ueda, Yoshimichi; Uramoto, Hidetaka
2018-04-09
Diffusion-weighted magnetic resonance imaging (DWI) is useful for detecting malignant tumors and the assessment of lymph nodes, as FDG-PET/CT is. But it is not clear how DWI influences the prognosis of lung cancer patients. The focus of this study is to evaluate the correlations between maximum standardized uptake value (SUVmax) of FDG-PET/CT and apparent diffusion coefficient (ADC) value of DWI with known prognostic factors in resected lung cancer. A total of 227 patients with resected lung cancers were enrolled in this study. FEG-PET/CT and DWI were performed in each patient before surgery. There were 168 patients with adenocarcinoma, 44 patients with squamous cell carcinoma, and 15 patients with other cell types. SUVmax was a factor that was correlated to T factor, N factor, or cell differentiation. ADC of lung cancer was a factor that was not correlated to T factor, or N factor. There was a significantly weak inverse relationship between SUVmax and ADC (Correlation coefficient r = - 0.227). In analysis of survival, there were significant differences between the categories of sex, age, pT factor, pN factor, cell differentiation, cell type, and SUVmax. Univariate analysis revealed that SUVmax, pN factor, age, cell differentiation, cell type, sex, and pT factor were significant factors. Multivariate analysis revealed that SUVmax and pN factor were independent significant prognostic factors. SUVmax was a significant prognostic factor that is correlated to T factor, N factor, or cell differentiation, but ADC was not. SUVmax may be more useful for predicting the prognosis of lung cancer than ADC values.
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study
Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.
2016-01-01
Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049
Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.
Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S
2016-01-01
To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.
Rocco, Paolo; Cilurzo, Francesco; Minghetti, Paola; Vistoli, Giulio; Pedretti, Alessandro
2017-10-01
The data presented in this article are related to the article titled "Molecular Dynamics as a tool for in silico screening of skin permeability" (Rocco et al., 2017) [1]. Knowledge of the confidence interval and maximum theoretical value of the correlation coefficient r can prove useful to estimate the reliability of developed predictive models, in particular when there is great variability in compiled experimental datasets. In this Data in Brief article, data from purposely designed numerical simulations are presented to show how much the maximum r value is worsened by increasing the data uncertainty. The corresponding confidence interval of r is determined by using the Fisher r → Z transform.
Wang, Fang
2016-06-01
In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρDXA, contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.
Surov, Alexey; Hamerla, Gordian; Meyer, Hans Jonas; Winter, Karsten; Schob, Stefan; Fiedler, Eckhard
2018-09-01
To analyze several histopathological features and their possible correlations with whole lesion histogram analysis derived from ADC maps in meningioma. The retrospective study involved 36 patients with primary meningiomas. For every tumor, the following histogram analysis parameters of apparent diffusion coefficient (ADC) were calculated: ADC mean , ADC max , ADC min , ADC median , ADC mode , ADC percentiles: P10, P25, P75, P90, as well kurtosis, skewness, and entropy. All measures were performed by two radiologists. Proliferation index KI 67, minimal, maximal and mean cell count, total nucleic area, and expression of water channel aquaporin 4 (AQP4) were estimated. Spearman's correlation coefficient was used to analyze associations between investigated parameters. A perfect interobserver agreement for all ADC values (0.84-0.97) was identified. All ADC values correlated inversely with tumor cellularity with the strongest correlation between P10, P25 and mean cell count (-0.558). KI 67 correlated inversely with all ADC values except ADC min . ADC parameters did not correlate with total nucleic area. All ADC values correlated statistically significant with expression of AQP4. ADC histogram analysis is a valid method with an excellent interobserver agreement. Cellularity parameters and proliferation potential are associated with different ADC values. Membrane permeability may play a greater role for water diffusion than cell count and proliferation activity. Copyright © 2018 Elsevier Inc. All rights reserved.
Prediction of stream volatilization coefficients
Rathbun, Ronald E.
1990-01-01
Equations are developed for predicting the liquid-film and gas-film reference-substance parameters for quantifying volatilization of organic solutes from streams. Molecular weight and molecular-diffusion coefficients of the solute are used as correlating parameters. Equations for predicting molecular-diffusion coefficients of organic solutes in water and air are developed, with molecular weight and molal volume as parameters. Mean absolute errors of prediction for diffusion coefficients in water are 9.97% for the molecular-weight equation, 6.45% for the molal-volume equation. The mean absolute error for the diffusion coefficient in air is 5.79% for the molal-volume equation. Molecular weight is not a satisfactory correlating parameter for diffusion in air because two equations are necessary to describe the values in the data set. The best predictive equation for the liquid-film reference-substance parameter has a mean absolute error of 5.74%, with molal volume as the correlating parameter. The best equation for the gas-film parameter has a mean absolute error of 7.80%, with molecular weight as the correlating parameter.
Correlation of ADC value with pathologic indexes in colorectal tumor homografts in Balb/c mouse.
Li, Xiaojun; Jiang, Hongnan; Niu, Jinliang; Zheng, Ying
2014-08-01
Noninvasive diffusion-weighted magnetic resonance imaging (DWI) is a well-studied MR imaging technique for quantifying water diffusion especially in tumor area. The correlation between apparent diffusion coefficient (ADC) value and apoptosis or proliferation is not clear by now. This study aimed to investigate whether DWI-ADC value could be used as an imaging marker related with pathologic indexes of tumors. A total of 30 Balb/c mice with HT29 colorectal carcinoma were subjected to DWI and histologic analysis. The percentage of ADC changes and the apoptotic and proliferating indexes were calculated at predefined time points. Kolmogorov-Smirnov distances were considered to determine whether the percentage of ADC changes, and the apoptotic and proliferating indexes were normally distributed. An independent-samples t-test was used to analyze the difference between apoptotic and proliferating indexes in the two groups. THERE WAS A STATISTICALLY SIGNIFICANT DIFFERENCE IN PROLIFERATING INDEX BETWEEN THE RADIOTHERAPY AND CONTROL GROUPS (MEAN PROLIFERATING INDEX: 49.27% vs. 83.09%), and there was a statistically significant difference in apoptotic index between the two groups (mean apoptotic index: 37.7% vs. 2.71%). A significant positive correlation was found between the percentage of ADC changes of the viable tissue and apoptotic index. Pearson's correlation coefficient was 0.655 (P=0.015). A significant negative correlation was found between the percentage of ADC changes of the viable tissue and ki-67 proliferation index. Pearson's correlation coefficient was 0.734 (P<0.001). Our results suggest that ADC value may be used in measurement of cell apoptotic and proliferating indexes in colorectal carcinoma.
Endarti, Dwi; Riewpaiboon, Arthorn; Thavorncharoensap, Montarat; Praditsitthikorn, Naiyana; Hutubessy, Raymond; Kristina, Susi Ari
2018-05-01
To gain insight into the most suitable foreign value set among Malaysian, Singaporean, Thai, and UK value sets for calculating the EuroQol five-dimensional questionnaire index score (utility) among patients with cervical cancer in Indonesia. Data from 87 patients with cervical cancer recruited from a referral hospital in Yogyakarta province, Indonesia, from an earlier study of health-related quality of life were used in this study. The differences among the utility scores derived from the four value sets were determined using the Friedman test. Performance of the psychometric properties of the four value sets versus visual analogue scale (VAS) was assessed. Intraclass correlation coefficients and Bland-Altman plots were used to test the agreement among the utility scores. Spearman ρ correlation coefficients were used to assess convergent validity between utility scores and patients' sociodemographic and clinical characteristics. With respect to known-group validity, the Kruskal-Wallis test was used to examine the differences in utility according to the stages of cancer. There was significant difference among utility scores derived from the four value sets, among which the Malaysian value set yielded higher utility than the other three value sets. Utility obtained from the Malaysian value set had more agreements with VAS than the other value sets versus VAS (intraclass correlation coefficients and Bland-Altman plot tests results). As for the validity, the four value sets showed equivalent psychometric properties as those that resulted from convergent and known-group validity tests. In the absence of an Indonesian value set, the Malaysian value set was more preferable to be used compared with the other value sets. Further studies on the development of an Indonesian value set need to be conducted. Copyright © 2018. Published by Elsevier Inc.
The Pittsburgh Sleep Quality Index: validation of the Urdu translation.
Hashmi, Ali Madeeh; Khawaja, Imran Shuja; Butt, Zeeshan; Umair, Muhammad; Naqvi, Suhaib Haider; Jawad-Ul-Haq
2014-02-01
To translate and validate the Pittsburgh Sleep Quality Index (PSQI), a standardized self-administered questionnaire for the assessment of subjective sleep quality into the Urdu language. Validation study. Mayo Hospital, Lahore, from March to April 2012. The PSQI was translated into Urdu following standard guidelines. The final Urdu version (PSQI-U) was administered to 200 healthy volunteers comprising medical students, nursing staff and doctors. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation of component scores with global score was assessed by calculating Spearman correlation coefficient. Correlation between global PSQI-U scores at baseline with global scores for each PSQI-U and PSQI-E at 4-week interval was evaluated by calculating Spearman correlation coefficient. Moreover, scores on individual items of the scale at baseline were compared with respective scores after 4-week by t-test. One hundred and eighty five (185) participants completed the PSQI-U at baseline. The Cronbach alpha for PSQI-U was 0.56. Scores on individual components of the PSQI-U and composite scores were all highly correlated with each other (all p-values < 0.01). Composite scores for PSQI-U at baseline and PSQI-E at 4-week interval were also highly correlated with each other (Spearman correlation coefficient 0.74, p-value < 0.01) indicating good linguistic interchangeability. Composite scores for PSQI-U at baseline and at 4-week interval were positively correlated with each other (Spearman correlation coefficient 0.70, p < 0.01) indicating good test-retest reliability. The PSQI-U is a valid and reliable instrument for the assessment of sleep quality. It shows good linguistic interchangeability and test-retest reliability in comparison to the original English version when applied to individuals who speak the Urdu language. The PSQI-U can be a tool either for clinical management or research.
Surov, Alexey; Meyer, Hans Jonas; Winter, Karsten; Richter, Cindy; Hoehn, Anna-Kathrin
2018-05-04
Our purpose was to analyze associations between apparent diffusion coefficient (ADC) histogram analysis parameters and histopathologicalfeatures in head and neck squamous cell carcinoma (HNSCC). The study involved 32 patients with primary HNSCC. For every tumor, the following histogram analysis parameters were calculated: ADCmean, ADCmax, ADC min , ADC median , ADC mode , P10, P25, P75, P90, kurtosis, skewness, and entropy. Furthermore, proliferation index KI 67, cell count, total and average nucleic areas were estimated. Spearman's correlation coefficient (p) was used to analyze associations between investigated parameters. In overall sample, all ADC values showed moderate inverse correlations with KI 67. All ADC values except ADCmax correlated inversely with tumor cellularity. Slightly correlations were identified between total/average nucleic area and ADC mean , ADC min , ADC median , and P25. In G1/2 tumors, only ADCmode correlated well with Ki67. No statistically significant correlations between ADC parameters and cellularity were found. In G3 tumors, Ki 67 correlated with all ADC parameters except ADCmode. Cell count correlated well with all ADC parameters except ADCmax. Total nucleic area correlated inversely with ADC mean , ADC min , ADC median , P25, and P90. ADC histogram parameters reflect proliferation potential and cellularity in HNSCC. The associations between histopathology and imaging depend on tumor grading.
Yu, Xue; Lee, Elaine Yuen Phin; Lai, Vincent; Chan, Queenie
2014-07-01
To evaluate the correlation between standardized uptake value (SUV) (tissue metabolism) and apparent diffusion coefficient (ADC) (water diffusivity) in peritoneal metastases. Patients with peritoneal dissemination detected on (18)F-fluorodeoxyglucose positron emission tomography combined with computed tomography (FDG-PET/CT) were prospectively recruited for MRI examinations with informed consent and the study was approved by the local Institutional Review Board. FDG-PET/CT, diffusion-weighted imaging (DWI), MRI, and DWI/MRI images were independently reviewed by two radiologists based on visual analysis. SUVmax/SUVmean and ADCmin/ADCmean were obtained manually by drawing ROIs over the peritoneal metastases on FDG-PET/CT and DWI, respectively. Diagnostic characteristics of each technique were evaluated. Pearson's coefficient and McNemar and Kappa tests were used for statistical analysis. Eight patients were recruited for this prospective study and 34 peritoneal metastases were evaluated. ADCmean was significantly and negatively correlated with SUVmax (r = -0.528, P = 0.001) and SUVmean (r = -0.548, P = 0.001). ADCmin had similar correlation with SUVmax (r = -0.508, P = 0.002) and SUVmean (r = -0.513, P = 0.002). DWI/MRI had high diagnostic performance (accuracy = 98%) comparable to FDG-PET/CT, in peritoneal metastasis detection. Kappa values were excellent for all techniques. There was a significant inverse correlation between SUV and ADC. © 2013 Wiley Periodicals, Inc.
Establishment of a Simple and Convenient Method for Folic Acid Enzyme Chemiluminescence Immunoassay
NASA Astrophysics Data System (ADS)
Liu, Ting; Zeng, Ling; Yu, Zhengwei; Yang, Yanfei; Qu, Yunhuan
2018-01-01
The enzyme chemiluminescence new immunoassay for folic acid (FA) was established by competition model. Add FA samples to a microtiter plate precoated with the goat anti-mouse IgG firstly, then add enzyme abled FA and FA monoclonal antibody (McAb). The values of CLIA were measured to reflect the quantity of FA. The limit of detection(LOD) of assay is 0.37ng/mL. The assay shows good correlation during 1∼30 ng/mL with correlation coefficient 0.9976. The intra- and inter-assay coefficients of variation are 4.8 % ∼ 7.3 % and 6.1 % ∼ 12.2 %, respectively. The recovery of folic acid in serum is 90.4 %∼113.2 %. Compared with determine value clinically in chemiluminescence immunoassay kit from Roche company, the correlative equation is y = 0.9689x + 0.0228, and correlation coefficient is 0.9780. Various components and kit overall show good stabilities. This method is simple and convenient, and has low LOD value. The method has overcome the shortcomings of the present references. It is easy to apply and has broad clinical application prospect. It lays an experimental foundation for the preparation of Mc Ab against folic acid and the development of domestic kit.
Closure and ratio correlation analysis of lunar chemical and grain size data
NASA Technical Reports Server (NTRS)
Butler, J. C.
1976-01-01
Major element and major element plus trace element analyses were selected from the lunar data base for Apollo 11, 12 and 15 basalt and regolith samples. Summary statistics for each of the six data sets were compiled, and the effects of closure on the Pearson product moment correlation coefficient were investigated using the Chayes and Kruskal approximation procedure. In general, there are two types of closure effects evident in these data sets: negative correlations of intermediate size which are solely the result of closure, and correlations of small absolute value which depart significantly from their expected closure correlations which are of intermediate size. It is shown that a positive closure correlation will arise only when the product of the coefficients of variation is very small (less than 0.01 for most data sets) and, in general, trace elements in the lunar data sets exhibit relatively large coefficients of variation.
Equations of prediction for abdominal fat in brown egg-laying hens fed different diets.
Souza, C; Jaimes, J J B; Gewehr, C E
2017-06-01
The objective was to use noninvasive measurements to formulate equations for predicting the abdominal fat weight of laying hens in a noninvasive manner. Hens were fed with different diets; the external body measurements of birds were used as regressors. We used 288 Hy-Line Brown laying hens, distributed in a completely randomized design in a factorial arrangement, submitted for 16 wk to 2 metabolizable energy levels (2,550 and 2,800 kcal/kg) and 3 levels of crude protein in the diet (150, 160, and 170 g/kg), totaling 6 treatments, with 48 hens each. Sixteen hens per treatment of 92 wk age were utilized to evaluate body weight, bird length, tarsus and sternum, greater and lesser diameter of the tarsus, and abdominal fat weight, after slaughter. The equations were obtained by using measures evaluated with regressors through simple and multiple linear regression with the stepwise method of indirect elimination (backward), with P < 0.10 for all variables remaining in the model. The weight of abdominal fat as predicted by the equations and observed values for each bird were subjected to Pearson's correlation analysis. The equations generated by energy levels showed coefficients of determination of 0.50 and 0.74 for 2,800 and 2,550 kcal/kg of metabolizable energy, respectively, with correlation coefficients of 0.71 and 0.84, with a highly significant correlation between the calculated and observed values of abdominal fat. For protein levels of 150, 160, and 170 g/kg in the diet, it was possible to obtain coefficients of determination of 0.75, 0.57, and 0.61, with correlation coefficients of 0.86, 0.75, and 0.78, respectively. Regarding the general equation for predicting abdominal fat weight, the coefficient of determination was 0.62; the correlation coefficient was 0.79. The equations for predicting abdominal fat weight in laying hens, based on external measurements of the birds, showed positive coefficients of determination and correlation coefficients, thus allowing researchers to determine abdominal fat weight in vivo. © 2016 Poultry Science Association Inc.
Experimental determination of turbulence in a GH2-GOX rocket combustion chamber
NASA Technical Reports Server (NTRS)
Tou, P.; Russell, R.; Ohara, J.
1974-01-01
The intensity of turbulence and the Lagrangian correlation coefficient for a gaseous rocket combustion chamber have been determined from the experimental measurements of the tracer gas diffusion. A combination of Taylor's turbulent diffusion theory and Spalding's numerical method for solving the conservation equations of fluid mechanics was used to calculate these quantities. Taylor's theory was extended to consider the inhomogeneity of the turbulence field in the axial direction of the combustion chamber. An exponential function was used to represent the Lagrangian correlation coefficient. The results indicate that the maximum value of the intensity of turbulence is about 15% and the Lagrangian correlation coefficient drops to about 0.12 in one inch of the chamber length.
Flores-Mir, Carlos; Burgess, Corr A; Champney, Mitchell; Jensen, Robert J; Pitcher, Micheal R; Major, Paul W
2006-01-01
The aim of this study was to assess the correlation between the Fishman maturation prediction method (FMP) and the cervical vertebral maturation (CVM) method for skeletal maturation stage determination. Hand-wrist and lateral cephalograms from 79 subjects (52 females and 27 males) were used. Hand-wrist radiographs were analyzed using the FMP to determine skeletal maturation level (advanced, average, or delayed) and stage (relative position of the individual in the pubertal growth curve). Cervical vertebrae (C2, C3, and C4) outlines obtained from lateral cephalograms were analyzed using the CVM to determine skeletal maturation stage. Intraexaminer reliability (Intraclass correlation coefficient [ICC]) for both methods was calculated from 10 triplicate hand-wrist and lateral cephalograms from the same patients. An ICC coefficient of 0.985 for FMP and an ICC of 0.889 for CVM were obtained. A Spearman correlation value of 0.72 (P < .001) was found between the skeletal maturation stages of both methods. When the sample was subgrouped according to skeletal maturation level, the following correlation values were found: for early mature adolescents 0.73, for average mature adolescents 0.70, and for late mature adolescents 0.87. All these correlation values were statistically different from zero (P < .024). Correlation values between both skeletal maturation methods were moderately high. This may be high enough to use either of the methods indistinctively for research purposes but not for the assessment of individual patients. Skeletal level influences the correlation values and, therefore, it should be considered whenever possible.
Rakheja, Rajan; Chandarana, Hersh; DeMello, Linda; Jackson, Kimberly; Geppert, Christian; Faul, David; Glielmi, Christopher; Friedman, Kent P
2013-11-01
The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation Criteria in Solid Tumors 1.1. The ratio between SUVmax and ADCmin was higher among patients with progressive disease than those with a partial treatment response. Simultaneous PET/MRI is a promising technology for the detection of neoplastic disease. There are inverse correlations between SUVmax and ADCmin and between SUV ratio and ADCmin. Correlation coefficients between SUVmax and ADCmin from PET/MRI were similar to values obtained with SUVmax from the same-day PET/CT. Given that both SUV and ADC are related to malignancy and that the correlation between the two biomarkers is relatively weak, SUV and ADC values may offer complementary information to aid in determination of prognosis and treatment response. The combined tumoral biomarker, ratio between SUVmax and ADCmin, may be useful for assessing progressive disease versus partial treatment response.
NASA Astrophysics Data System (ADS)
Wang, Fang
2016-06-01
In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρ D X A , contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.
Restoration of acidic mine spoils with sewage sludge: II measurement of solids applied
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stucky, D.J.; Zoeller, A.L.
1980-01-01
Sewage sludge was incorporated in acidic strip mine spoils at rates equivalent to 0, 224, 336, and 448 dry metric tons (dmt)/ha and placed in pots in a greenhouse. Spoil parameters were determined 48 hours after sludge incorporation, Time Planting (P), and five months after orchardgrass (Dactylis glomerata L.) was planted, Time Harvest (H), in the pots. Parameters measured were: pH, organic matter content (OM), cation exchange capacity (CEC), electrical conductivity (EC) and yield. Values for each parameter were significantly different at the two sampling times. Correlation coefficient values were calculated for all parameters versus rates of applied sewage sludgemore » and all parameters versus each other. Multiple regressions were performed, stepwise, for all parameters versus rates of applied sewage sludge. Equations to predict amounts of sewage sludge incorporated in spoils were derived for individual and multiple parameters. Generally, measurements made at Time P achieved the highest correlation coefficient and multiple correlation coefficient values; therefore, the authors concluded data from Time P had the greatest predictability value. The most important value measured to predict rate of applied sewage sludge was pH and some additional accuracy was obtained by including CEC in equation. This experiment indicated that soil properties can be used to estimate amounts of sewage sludge solids required to reclaim acidic mine spoils and to estimate quantities incorporated.« less
Sagiyama, Koji; Watanabe, Yuji; Kamei, Ryotaro; Hong, Sungtak; Kawanami, Satoshi; Matsumoto, Yoshihiro; Honda, Hiroshi
2017-12-01
To investigate the usefulness of voxel-based analysis of standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs) for evaluating soft-tissue tumour malignancy with a PET/MR system. Thirty-five subjects with either ten low/intermediate-grade tumours or 25 high-grade tumours were prospectively enrolled. Zoomed diffusion-weighted and fluorodeoxyglucose ( 18 FDG)-PET images were acquired along with fat-suppressed T2-weighted images (FST2WIs). Regions of interest (ROIs) were drawn on FST2WIs including the tumour in all slices. ROIs were pasted onto PET and ADC-maps to measure SUVs and ADCs within tumour ROIs. Tumour volume, SUVmax, ADCminimum, the heterogeneity and the correlation coefficients of SUV and ADC were recorded. The parameters of high- and low/intermediate-grade groups were compared, and receiver operating characteristic (ROC) analysis was also performed. The mean correlation coefficient for SUV and ADC in high-grade sarcomas was lower than that of low/intermediate-grade tumours (-0.41 ± 0.25 vs. -0.08 ± 0.34, P < 0.01). Other parameters did not differ significantly. ROC analysis demonstrated that correlation coefficient showed the best diagnostic performance for differentiating the two groups (AUC 0.79, sensitivity 96.0%, specificity 60%, accuracy 85.7%). SUV and ADC determined via PET/MR may be useful for differentiating between high-grade and low/intermediate-grade soft tissue tumours. • PET/MR allows voxel-based comparison of SUVs and ADCs in soft-tissue tumours. • A comprehensive assessment of internal heterogeneity was performed with scatter plots. • SUVmax or ADCminimum could not differentiate high-grade sarcoma from low/intermediate-grade tumours. • Only the correlation coefficient between SUV and ADC differentiated the two groups. • The correlation coefficient showed the best diagnostic performance by ROC analysis.
Prediction of kinase-inhibitor binding affinity using energetic parameters
Usha, Singaravelu; Selvaraj, Samuel
2016-01-01
The combination of physicochemical properties and energetic parameters derived from protein-ligand complexes play a vital role in determining the biological activity of a molecule. In the present work, protein-ligand interaction energy along with logP values was used to predict the experimental log (IC50) values of 25 different kinase-inhibitors using multiple regressions which gave a correlation coefficient of 0.93. The regression equation obtained was tested on 93 kinase-inhibitor complexes and an average deviation of 0.92 from the experimental log IC50 values was shown. The same set of descriptors was used to predict binding affinities for a test set of five individual kinase families, with correlation values > 0.9. We show that the protein-ligand interaction energies and partition coefficient values form the major deterministic factors for binding affinity of the ligand for its receptor. PMID:28149052
Gunnala, Vishal; Guo, Rong; Minutti, Carla; Durazo-Arvizu, Ramon; Laporte, Cynthia; Mathews, Herbert; Kliethermis, Stephanie; Bhatia, Rahul
2015-05-01
To compare serum total, serum free and salivary cortisol in critically ill children. Prospective observational cohort study. Tertiary pediatric critical care unit at Ronald McDonald Children's Hospital at Loyola University Medical Center. We enrolled 59 patients (4 weeks to 18 years of age) between January 2012 and May 2013. Thirty-four patients were included in the salivary to serum free cortisol correlational analysis. Blood and saliva samples were obtained simultaneously within 24 hours of admission between the hours of 6 AM and 12 PM. Salivary cortisol was tested by liquid chromatography/tandem mass spectrometry, serum free cortisol by liquid chromatography/tandem mass spectrometry followed by equilibrium dialysis, and serum total cortisol by liquid chromatography/tandem mass spectrometry. Salivary and serum free cortisol values from 34 patients had a correlation coefficient (r) of 0.87 (95% CI, 0.75-0.93; p < 0.0001). The total serum and salivary cortisol values had a correlation coefficient (r) of 0.67 (95% CI, 0.42-0.81; p < 0.0001). The total serum and serum free cortisol values had a correlation coefficient (r) of 0.83 (95% CI, 0.69-0.91; p < 0.0001). Serum free and salivary cortisol values correlate in critically ill children. Salivary cortisol can be used as a surrogate for serum free cortisol in critically ill pediatric patients. Salivary cortisol is a cost-effective and less invasive measure of bioavailable cortisol and offers an alternate and accurate method for assessing critical illness-related corticosteroid insufficiency in children.
Uwano, Ikuko; Sasaki, Makoto; Kudo, Kohsuke; Boutelier, Timothé; Kameda, Hiroyuki; Mori, Futoshi; Yamashita, Fumio
2017-01-10
The Bayesian estimation algorithm improves the precision of bolus tracking perfusion imaging. However, this algorithm cannot directly calculate Tmax, the time scale widely used to identify ischemic penumbra, because Tmax is a non-physiological, artificial index that reflects the tracer arrival delay (TD) and other parameters. We calculated Tmax from the TD and mean transit time (MTT) obtained by the Bayesian algorithm and determined its accuracy in comparison with Tmax obtained by singular value decomposition (SVD) algorithms. The TD and MTT maps were generated by the Bayesian algorithm applied to digital phantoms with time-concentration curves that reflected a range of values for various perfusion metrics using a global arterial input function. Tmax was calculated from the TD and MTT using constants obtained by a linear least-squares fit to Tmax obtained from the two SVD algorithms that showed the best benchmarks in a previous study. Correlations between the Tmax values obtained by the Bayesian and SVD methods were examined. The Bayesian algorithm yielded accurate TD and MTT values relative to the true values of the digital phantom. Tmax calculated from the TD and MTT values with the least-squares fit constants showed excellent correlation (Pearson's correlation coefficient = 0.99) and agreement (intraclass correlation coefficient = 0.99) with Tmax obtained from SVD algorithms. Quantitative analyses of Tmax values calculated from Bayesian-estimation algorithm-derived TD and MTT from a digital phantom correlated and agreed well with Tmax values determined using SVD algorithms.
Correlation of morphological and molecular parameters for colon cancer
NASA Astrophysics Data System (ADS)
Yuan, Shuai; Roney, Celeste A.; Li, Qian; Jiang, James; Cable, Alex; Summers, Ronald M.; Chen, Yu
2010-02-01
Colorectal cancer (CRC) is the second leading cause of cancer death in the United States. There is great interest in studying the relationship among microstructures and molecular processes of colorectal cancer during its progression at early stages. In this study, we use our multi-modality optical system that could obtain co-registered optical coherence tomography (OCT) and fluorescence molecular imaging (FMI) images simultaneously to study CRC. The overexpressed carbohydrate α-L-fucose on the surfaces of polyps facilitates the bond of adenomatous polyps with UEA-1 and is used as biomarker. Tissue scattering coefficient derived from OCT axial scan is used as quantitative value of structural information. Both structural images from OCT and molecular images show spatial heterogeneity of tumors. Correlations between those values are analyzed and demonstrate that scattering coefficients are positively correlated with FMI signals in conjugated. In UEA-1 conjugated samples (8 polyps and 8 control regions), the correlation coefficient is ranged from 0.45 to 0.99. These findings indicate that the microstructure of polyps is changed gradually during cancer progression and the change is well correlated with certain molecular process. Our study demonstrated that multi-parametric imaging is able to simultaneously detect morphology and molecular information and it can enable spatially and temporally correlated studies of structure-function relationships during tumor progression.
Shrinkage regression-based methods for microarray missing value imputation.
Wang, Hsiuying; Chiu, Chia-Chun; Wu, Yi-Ching; Wu, Wei-Sheng
2013-01-01
Missing values commonly occur in the microarray data, which usually contain more than 5% missing values with up to 90% of genes affected. Inaccurate missing value estimation results in reducing the power of downstream microarray data analyses. Many types of methods have been developed to estimate missing values. Among them, the regression-based methods are very popular and have been shown to perform better than the other types of methods in many testing microarray datasets. To further improve the performances of the regression-based methods, we propose shrinkage regression-based methods. Our methods take the advantage of the correlation structure in the microarray data and select similar genes for the target gene by Pearson correlation coefficients. Besides, our methods incorporate the least squares principle, utilize a shrinkage estimation approach to adjust the coefficients of the regression model, and then use the new coefficients to estimate missing values. Simulation results show that the proposed methods provide more accurate missing value estimation in six testing microarray datasets than the existing regression-based methods do. Imputation of missing values is a very important aspect of microarray data analyses because most of the downstream analyses require a complete dataset. Therefore, exploring accurate and efficient methods for estimating missing values has become an essential issue. Since our proposed shrinkage regression-based methods can provide accurate missing value estimation, they are competitive alternatives to the existing regression-based methods.
NASA Astrophysics Data System (ADS)
Gang, Zhang; Fansong, Meng; Jianzhong, Wang; Mingtao, Ding
2018-02-01
Determining magnetotelluric impedance precisely and accurately is fundamental to valid inversion and geological interpretation. This study aims to determine the minimum value of signal-to-noise ratio (SNR) which maintains the effectiveness of remote reference technique. Results of standard time series simulation, addition of different Gaussian noises to obtain the different SNR time series, and analysis of the intermediate data, such as polarization direction, correlation coefficient, and impedance tensor, show that when the SNR value is larger than 23.5743, the polarization direction disorder at morphology and a smooth and accurate sounding carve value can be obtained. At this condition, the correlation coefficient value of nearly complete segments between the base and remote station is larger than 0.9, and impedance tensor Zxy presents only one aggregation, which meet the natural magnetotelluric signal characteristic.
Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike
2018-02-24
To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.
Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente
2014-06-01
The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p < 0.05), suggesting excellent reliability of the measurements. Muscle-fat fraction measurements from water-fat MRI exhibited the highest intraclass correlation coefficient. Interrater agreement was consistently better than test-retest comparisons. Water-fat MRI and DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.
Heat transfer to horizontal tubes in a pilot-scale fluidized-bed combustor burning low-rank coals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grewal, N.S.; Goblirsch, G.
Experimental data are obtained for the heat transfer coefficient between immersed horizontal tube bundles and an atmospheric-fluidized-bed combustor burning low-rank coals. Silica sand (d/sub p/ = 888 to 1484 ..mu..m) and limestone (d/sub p/ = 716 to 1895 ..mu..m) are used as bed material. The tests are conducted, with and without limestone addition and ash recycle, at average bed temperatures ranging from 1047 to 1125/sup 0/K, superficial fluidizing velocity of 1.66 to 2.04 m/s, and excess air levels of 15 to 40 percent. The experimental data are examined in the light of the existing correlations for the heat transfer coefficient.more » The predicted values of heat transfer coefficient from the correlations proposed by Grewal (1981) and Bansal et al. (1980) are found to be within +-25 percent of the experimental values of heat transfer coefficient, when the contribution due to radiation is also included. 5 figures, 5 tables.« less
Investigation of oscillating cascade aerodynamics by an experimental influence coefficient technique
NASA Technical Reports Server (NTRS)
Buffum, Daniel H.; Fleeter, Sanford
1988-01-01
Fundamental experiments are performed in the NASA Lewis Transonic Oscillating Cascade Facility to investigate the torsion mode unsteady aerodynamics of a biconvex airfoil cascade at realistic values of the reduced frequency for all interblade phase angles at a specified mean flow condition. In particular, an unsteady aerodynamic influence coefficient technique is developed and utilized in which only one airfoil in the cascade is oscillated at a time and the resulting airfoil surface unsteady pressure distribution measured on one dynamically instrumented airfoil. The unsteady aerodynamics of an equivalent cascade with all airfoils oscillating at a specified interblade phase angle are then determined through a vector summation of these data. These influence coefficient determined oscillation cascade data are correlated with data obtained in this cascade with all airfoils oscillating at several interblade phase angle values. The influence coefficients are then utilized to determine the unsteady aerodynamics of the cascade for all interblade phase angles, with these unique data subsequently correlated with predictions from a linearized unsteady cascade model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ma, C; Yin, Y
Purpose: The purpose of this research is investigating which texture features extracted from FDG-PET images by gray-level co-occurrence matrix(GLCM) have a higher prognostic value than the other texture features. Methods: 21 non-small cell lung cancer(NSCLC) patients were approved in the study. Patients underwent 18F-FDG PET/CT scans with both pre-treatment and post-treatment. Firstly, the tumors were extracted by our house developed software. Secondly, the clinical features including the maximum SUV and tumor volume were extracted by MIM vista software, and texture features including angular second moment, contrast, inverse different moment, entropy and correlation were extracted using MATLAB.The differences can be calculatedmore » by using post-treatment features to subtract pre-treatment features. Finally, the SPSS software was used to get the Pearson correlation coefficients and Spearman rank correlation coefficients between the change ratios of texture features and change ratios of clinical features. Results: The Pearson and Spearman rank correlation coefficient between contrast and SUV maximum is 0.785 and 0.709. The P and S value between inverse difference moment and tumor volume is 0.953 and 0.942. Conclusion: This preliminary study showed that the relationships between different texture features and the same clinical feature are different. Finding the prognostic value of contrast and inverse difference moment were higher than the other three textures extracted by GLCM.« less
Vendelin, Marko; Birkedal, Rikke
2008-01-01
A series of experimental data points to the existence of profound diffusion restrictions of ADP/ATP in rat cardiomyocytes. This assumption is required to explain the measurements of kinetics of respiration, sarcoplasmic reticulum loading with calcium, and kinetics of ATP-sensitive potassium channels. To be able to analyze and estimate the role of intracellular diffusion restrictions on bioenergetics, the intracellular diffusion coefficients of metabolites have to be determined. The aim of this work was to develop a practical method for determining diffusion coefficients in anisotropic medium and to estimate the overall diffusion coefficients of fluorescently labeled ATP in rat cardiomyocytes. For that, we have extended raster image correlation spectroscopy (RICS) protocols to be able to discriminate the anisotropy in the diffusion coefficient tensor. Using this extended protocol, we estimated diffusion coefficients of ATP labeled with the fluorescent conjugate Alexa Fluor 647 (Alexa-ATP). In the analysis, we assumed that the diffusion tensor can be described by two values: diffusion coefficient along the myofibril and that across it. The average diffusion coefficients found for Alexa-ATP were as follows: 83 ± 14 μm2/s in the longitudinal and 52 ± 16 μm2/s in the transverse directions (n = 8, mean ± SD). Those values are ∼2 (longitudinal) and ∼3.5 (transverse) times smaller than the diffusion coefficient value estimated for the surrounding solution. Such uneven reduction of average diffusion coefficient leads to anisotropic diffusion in rat cardiomyocytes. Although the source for such anisotropy is uncertain, we speculate that it may be induced by the ordered pattern of intracellular structures in rat cardiomyocytes. PMID:18815224
Karmonik, C; Anderson, J R; Beilner, J; Ge, J J; Partovi, S; Klucznik, R P; Diaz, O; Zhang, Y J; Britz, G W; Grossman, R G; Lv, N; Huang, Q
2016-07-26
To quantify the relationship and to demonstrate redundancies between hemodynamic and structural parameters before and after virtual treatment with a flow diverter device (FDD) in cerebral aneurysms. Steady computational fluid dynamics (CFD) simulations were performed for 10 cerebral aneurysms where FDD treatment with the SILK device was simulated by virtually reducing the porosity at the aneurysm ostium. Velocity and pressure values proximal and distal to and at the aneurysm ostium as well as inside the aneurysm were quantified. In addition, dome-to-neck ratios and size ratios were determined. Multiple correlation analysis (MCA) and hierarchical cluster analysis (HCA) were conducted to demonstrate dependencies between both structural and hemodynamic parameters. Velocities in the aneurysm were reduced by 0.14m/s on average and correlated significantly (p<0.05) with velocity values in the parent artery (average correlation coefficient: 0.70). Pressure changes in the aneurysm correlated significantly with pressure values in the parent artery and aneurysm (average correlation coefficient: 0.87). MCA found statistically significant correlations between velocity values and between pressure values, respectively. HCA sorted velocity parameters, pressure parameters and structural parameters into different hierarchical clusters. HCA of aneurysms based on the parameter values yielded similar results by either including all (n=22) or only non-redundant parameters (n=2, 3 and 4). Hemodynamic and structural parameters before and after virtual FDD treatment show strong inter-correlations. Redundancy of parameters was demonstrated with hierarchical cluster analysis. Copyright © 2015 Elsevier Ltd. All rights reserved.
A comparison of two indices for the intraclass correlation coefficient.
Shieh, Gwowen
2012-12-01
In the present study, we examined the behavior of two indices for measuring the intraclass correlation in the one-way random effects model: the prevailing ICC(1) (Fisher, 1938) and the corrected eta-squared (Bliese & Halverson, 1998). These two procedures differ both in their methods of estimating the variance components that define the intraclass correlation coefficient and in their performance of bias and mean squared error in the estimation of the intraclass correlation coefficient. In contrast with the natural unbiased principle used to construct ICC(1), in the present study it was analytically shown that the corrected eta-squared estimator is identical to the maximum likelihood estimator and the pairwise estimator under equal group sizes. Moreover, the empirical results obtained from the present Monte Carlo simulation study across various group structures revealed the mutual dominance relationship between their truncated versions for negative values. The corrected eta-squared estimator performs better than the ICC(1) estimator when the underlying population intraclass correlation coefficient is small. Conversely, ICC(1) has a clear advantage over the corrected eta-squared for medium and large magnitudes of population intraclass correlation coefficient. The conceptual description and numerical investigation provide guidelines to help researchers choose between the two indices for more accurate reliability analysis in multilevel research.
Sun, Yiqun; Tong, Tong; Cai, Sanjun; Bi, Rui; Xin, Chao; Gu, Yajia
2014-01-01
We elected to analyze the correlation between the pre-treatment apparent diffusion coefficient (ADC) and the clinical, histological, and immunohistochemical status of rectal cancers. Forty-nine rectal cancer patients who received surgical resection without neoadjuvant therapy were selected that underwent primary MRI and diffusion-weighted imaging (DWI). Tumor ADC values were determined and analyzed to identify any correlations between these values and pre-treatment CEA or CA19-9 levels, and/or the histological and immunohistochemical properties of the tumor. Inter-observer agreement of confidence levels from two separate observers was suitable for ADC measurement (k = 0.775). The pre-treatment ADC values of different T stage tumors were not equal (p = 0.003). The overall trend was that higher T stage values correlated with lower ADC values. ADC values were also significantly lower for the following conditions: tumors with the presence of extranodal tumor deposits (p = 0.006) and tumors with CA19-9 levels ≥ 35 g/ml (p = 0.006). There was a negative correlation between Ki-67 LI and the ADC value (r = -0.318, p = 0.026) and between the AgNOR count and the ADC value (r = -0.310, p = 0.030). Significant correlations were found between the pre-treatment ADC values and T stage, extranodal tumor deposits, CA19-9 levels, Ki-67 LI, and AgNOR counts in our study. Lower ADC values were associated with more aggressive tumor behavior. Therefore, the ADC value may represent a useful biomarker for assessing the biological features and possible relationship to the status of identified rectal cancers.
Xu, Feng; Liang, Xinmiao; Lin, Bingcheng; Schramm, Karl-Werner; Kettrup, Antonius
2002-08-30
The retention factors (k) of 104 hydrophobic organic chemicals (HOCs) were measured in soil column chromatography (SCC) over columns filled with three naturally occurring reference soils and eluted with Milli-Q water. A novel method for the estimation of soil organic partition coefficient (Koc) was developed based on correlations with k in soil/water systems. Strong log Koc versus log k correlations (r>0.96) were found. The estimated Koc values were in accordance with the literature values with a maximum deviation of less than 0.4 log units. All estimated Koc values from three soils were consistent with each other. The SCC approach is promising for fast screening of a large number of chemicals in their environmental applications.
NASA Astrophysics Data System (ADS)
Zhao, Jinping; Cao, Yong; Wang, Xin
2018-06-01
In order to study the temporal variations of correlations between two time series, a running correlation coefficient (RCC) could be used. An RCC is calculated for a given time window, and the window is then moved sequentially through time. The current calculation method for RCCs is based on the general definition of the Pearson product-moment correlation coefficient, calculated with the data within the time window, which we call the local running correlation coefficient (LRCC). The LRCC is calculated via the two anomalies corresponding to the two local means, meanwhile, the local means also vary. It is cleared up that the LRCC reflects only the correlation between the two anomalies within the time window but fails to exhibit the contributions of the two varying means. To address this problem, two unchanged means obtained from all available data are adopted to calculate an RCC, which is called the synthetic running correlation coefficient (SRCC). When the anomaly variations are dominant, the two RCCs are similar. However, when the variations of the means are dominant, the difference between the two RCCs becomes obvious. The SRCC reflects the correlations of both the anomaly variations and the variations of the means. Therefore, the SRCCs from different time points are intercomparable. A criterion for the superiority of the RCC algorithm is that the average value of the RCC should be close to the global correlation coefficient calculated using all data. The SRCC always meets this criterion, while the LRCC sometimes fails. Therefore, the SRCC is better than the LRCC for running correlations. We suggest using the SRCC to calculate the RCCs.
Two-Way Gene Interaction From Microarray Data Based on Correlation Methods.
Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh
2016-06-01
Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman's rank correlation coefficient and Blomqvist's measure, and compared them with Pearson's correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson's correlation, Spearman's rank correlation, and Blomqvist's coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist's coefficient was not confirmed by visual methods. Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data.
Relationship between photoreceptor outer segment length and visual acuity in diabetic macular edema.
Forooghian, Farzin; Stetson, Paul F; Meyer, Scott A; Chew, Emily Y; Wong, Wai T; Cukras, Catherine; Meyerle, Catherine B; Ferris, Frederick L
2010-01-01
The purpose of this study was to quantify photoreceptor outer segment (PROS) length in 27 consecutive patients (30 eyes) with diabetic macular edema using spectral domain optical coherence tomography and to describe the correlation between PROS length and visual acuity. Three spectral domain-optical coherence tomography scans were performed on all eyes during each session using Cirrus HD-OCT. A prototype algorithm was developed for quantitative assessment of PROS length. Retinal thicknesses and PROS lengths were calculated for 3 parameters: macular grid (6 x 6 mm), central subfield (1 mm), and center foveal point (0.33 mm). Intrasession repeatability was assessed using coefficient of variation and intraclass correlation coefficient. The association between retinal thickness and PROS length with visual acuity was assessed using linear regression and Pearson correlation analyses. The main outcome measures include intrasession repeatability of macular parameters and correlation of these parameters with visual acuity. Mean retinal thickness and PROS length were 298 mum to 381 microm and 30 microm to 32 mum, respectively, for macular parameters assessed in this study. Coefficient of variation values were 0.75% to 4.13% for retinal thickness and 1.97% to 14.01% for PROS length. Intraclass correlation coefficient values were 0.96 to 0.99 and 0.73 to 0.98 for retinal thickness and PROS length, respectively. Slopes from linear regression analyses assessing the association of retinal thickness and visual acuity were not significantly different from 0 (P > 0.20), whereas the slopes of PROS length and visual acuity were significantly different from 0 (P < 0.0005). Correlation coefficients for macular thickness and visual acuity ranged from 0.13 to 0.22, whereas coefficients for PROS length and visual acuity ranged from -0.61 to -0.81. Photoreceptor outer segment length can be quantitatively assessed using Cirrus HD-OCT. Although the intrasession repeatability of PROS measurements was less than that of macular thickness measurements, the stronger correlation of PROS length with visual acuity suggests that the PROS measures may be more directly related to visual function. Photoreceptor outer segment length may be a useful physiologic outcome measure, both clinically and as a direct assessment of treatment effects.
Praxedes, Marcus Fernando da Silva; de Abreu, Mauro Henrique Nogueira Guimarães; Paiva, Saul Martins; Mambrini, Juliana Vaz de Melo; Marcolino, Milena Soriano; Martins, Maria Auxiliadora Parreiras
2016-06-24
The aim of this study was to evaluate the psychometric properties of the Brazilian version of the Oral Anticoagulation Knowledge (OAK) Test. This study, conducted in an anticoagulation clinic, included 201 Brazilian participants aged over 18 years, who had been using warfarin for more than two months. The reliability of the instrument was evaluated by assessing internal consistency (Kuder-Richardson coefficient) and reproducibility (test-retest reliability). The validity was evaluated by hypothesizing that there would be a positive correlation of moderate to strong intensity between the correctness levels of the OAK Test and time within therapeutic range (TTR) values, which is a measure used to evaluate the quality of oral anticoagulation. The instrument exhibited good psychometric properties. The total a Kuder-Richardson coefficient value was 0.818 and intraclass correlation coefficient was 0.967. The validity revealed a strong positive correlation between the values of the level of knowledge, as measured by the OAK Test and the TTR values (rs = 0.780). The instrument proved to be a reliable and valid tool for evaluating the knowledge of Brazilian patients on oral anticoagulation therapy with warfarin. This instrument may be incorporated into the practice of health care for substantiating the structuring of educational activities to ensure the improvement of knowledge about the use of warfarin, thereby increasing the effectiveness and safety of treatment.
Measurement of the transverse polarization of electrons emitted in free-neutron decay.
Kozela, A; Ban, G; Białek, A; Bodek, K; Gorel, P; Kirch, K; Kistryn, St; Kuźniak, M; Naviliat-Cuncic, O; Pulut, J; Severijns, N; Stephan, E; Zejma, J
2009-05-01
Both components of the transverse polarization of electrons (sigmaT1, sigmaT2) emitted in the beta-decay of polarized, free neutrons have been measured. The T-odd, P-odd correlation coefficient quantifying sigmaT2, perpendicular to the neutron polarization and electron momentum, was found to be R=0.008+/-0.015+/-0.005. This value is consistent with time reversal invariance and significantly improves limits on the relative strength of imaginary scalar couplings in the weak interaction. The value obtained for the correlation coefficient associated with sigmaT1, N=0.056+/-0.011+/-0.005, agrees with the Standard Model expectation, providing an important sensitivity test of the experimental setup.
Development of stock correlation networks using mutual information and financial big data.
Guo, Xue; Zhang, Hu; Tian, Tianhai
2018-01-01
Stock correlation networks use stock price data to explore the relationship between different stocks listed in the stock market. Currently this relationship is dominantly measured by the Pearson correlation coefficient. However, financial data suggest that nonlinear relationships may exist in the stock prices of different shares. To address this issue, this work uses mutual information to characterize the nonlinear relationship between stocks. Using 280 stocks traded at the Shanghai Stocks Exchange in China during the period of 2014-2016, we first compare the effectiveness of the correlation coefficient and mutual information for measuring stock relationships. Based on these two measures, we then develop two stock networks using the Minimum Spanning Tree method and study the topological properties of these networks, including degree, path length and the power-law distribution. The relationship network based on mutual information has a better distribution of the degree and larger value of the power-law distribution than those using the correlation coefficient. Numerical results show that mutual information is a more effective approach than the correlation coefficient to measure the stock relationship in a stock market that may undergo large fluctuations of stock prices.
Development of stock correlation networks using mutual information and financial big data
Guo, Xue; Zhang, Hu
2018-01-01
Stock correlation networks use stock price data to explore the relationship between different stocks listed in the stock market. Currently this relationship is dominantly measured by the Pearson correlation coefficient. However, financial data suggest that nonlinear relationships may exist in the stock prices of different shares. To address this issue, this work uses mutual information to characterize the nonlinear relationship between stocks. Using 280 stocks traded at the Shanghai Stocks Exchange in China during the period of 2014-2016, we first compare the effectiveness of the correlation coefficient and mutual information for measuring stock relationships. Based on these two measures, we then develop two stock networks using the Minimum Spanning Tree method and study the topological properties of these networks, including degree, path length and the power-law distribution. The relationship network based on mutual information has a better distribution of the degree and larger value of the power-law distribution than those using the correlation coefficient. Numerical results show that mutual information is a more effective approach than the correlation coefficient to measure the stock relationship in a stock market that may undergo large fluctuations of stock prices. PMID:29668715
Xu, Xiao Quan; Choi, Young Jun; Sung, Yu Sub; Yoon, Ra Gyoung; Jang, Seung Won; Park, Ji Eun; Heo, Young Jin; Baek, Jung Hwan; Lee, Jeong Hyun
2016-01-01
To investigate the correlation between perfusion- and diffusion-related parameters from intravoxel incoherent motion (IVIM) and those from dynamic contrast-enhanced MR imaging (DCE-MRI) and diffusion-weighted imaging in tumors and normal muscles of the head and neck. We retrospectively enrolled 20 consecutive patients with head and neck tumors with MR imaging performed using a 3T MR scanner. Tissue diffusivity (D), pseudo-diffusion coefficient (D(*)), and perfusion fraction (f) were derived from bi-exponential fitting of IVIM data obtained with 14 different b-values in three orthogonal directions. We investigated the correlation between D, f, and D(*) and model-free parameters from the DCE-MRI (wash-in, Tmax, Emax, initial AUC60, whole AUC) and the apparent diffusion coefficient (ADC) value in the tumor and normal masseter muscle using a whole volume-of-interest approach. Pearson's correlation test was used for statistical analysis. No correlation was found between f or D(*) and any of the parameters from the DCE-MRI in all patients or in patients with squamous cell carcinoma (p > 0.05). The ADC was significantly correlated with D values in the tumors (p < 0.001, r = 0.980) and muscles (p = 0.013, r = 0.542), despite its significantly higher value than D. The difference between ADC and D showed significant correlation with f values in the tumors (p = 0.017, r = 0.528) and muscles (p = 0.003, r = 0.630), but no correlation with D(*) (p > 0.05, respectively). Intravoxel incoherent motion shows no significant correlation with model-free perfusion parameters derived from the DCE-MRI but is feasible for the analysis of diffusivity in both tumors and normal muscles of the head and neck.
Lian, Yanyun; Song, Zhijian
2014-01-01
Brain tumor segmentation from magnetic resonance imaging (MRI) is an important step toward surgical planning, treatment planning, monitoring of therapy. However, manual tumor segmentation commonly used in clinic is time-consuming and challenging, and none of the existed automated methods are highly robust, reliable and efficient in clinic application. An accurate and automated tumor segmentation method has been developed for brain tumor segmentation that will provide reproducible and objective results close to manual segmentation results. Based on the symmetry of human brain, we employed sliding-window technique and correlation coefficient to locate the tumor position. At first, the image to be segmented was normalized, rotated, denoised, and bisected. Subsequently, through vertical and horizontal sliding-windows technique in turn, that is, two windows in the left and the right part of brain image moving simultaneously pixel by pixel in two parts of brain image, along with calculating of correlation coefficient of two windows, two windows with minimal correlation coefficient were obtained, and the window with bigger average gray value is the location of tumor and the pixel with biggest gray value is the locating point of tumor. At last, the segmentation threshold was decided by the average gray value of the pixels in the square with center at the locating point and 10 pixels of side length, and threshold segmentation and morphological operations were used to acquire the final tumor region. The method was evaluated on 3D FSPGR brain MR images of 10 patients. As a result, the average ratio of correct location was 93.4% for 575 slices containing tumor, the average Dice similarity coefficient was 0.77 for one scan, and the average time spent on one scan was 40 seconds. An fully automated, simple and efficient segmentation method for brain tumor is proposed and promising for future clinic use. Correlation coefficient is a new and effective feature for tumor location.
[Surface electromyography signal classification using gray system theory].
Xie, Hongbo; Ma, Congbin; Wang, Zhizhong; Huang, Hai
2004-12-01
A new method based on gray correlation was introduced to improve the identification rate in artificial limb. The electromyography (EMG) signal was first transformed into time-frequency domain by wavelet transform. Singular value decomposition (SVD) was then used to extract feature vector from the wavelet coefficient for pattern recognition. The decision was made according to the maximum gray correlation coefficient. Compared with neural network recognition, this robust method has an almost equivalent recognition rate but much lower computation costs and less training samples.
Borowitz, Drucy; Lin, Rong; Baker, Susan S
2007-02-01
Two enzyme-linked immunosorbent assay methodologies are used to detect pancreatic insufficiency: monoclonal and polyclonal. We sought to compare these assays in patients with cystic fibrosis and to correlate these with the coefficient of fat absorption (CFA). As part of a larger study, subjects had stool elastase measured by both methods while taking exogenous enzymes. Subjects subsequently stopped enzymes and had a fecal fat balance study performed; the CFA was then calculated. One hundred twenty-four subjects participated in this substudy. The median values for the monoclonal and polyclonal assays were 0.3 and 22.75 microg/g, respectively. The correlation coefficient between the 2 tests was 0.86 (P < 0.0001). The correlation coefficients between CFA and the monoclonal and polyclonal assays were 0.24 (P = 0.006) and 0.10 (P = 0.27), respectively. If the criterion standard definition of pancreatic insufficiency was set at a CFA < 90% and the test definition of pancreatic insufficiency was set at <100 microg/g, then the monoclonal and polyclonal assay positive predictive values were 97.6% (120 of 123) and 97.4% (111 of 114), respectively. The positive predictive value of both monoclonal and polyclonal fecal elastase in patients with cystic fibrosis is extremely good; however, correlation of either test with CFA was poor. The median value for the polyclonal elastase assay is higher than for the monoclonal assay, which could potentially lead to lower sensitivity of the polyclonal assay at lower cutpoints for the monoclonal assay is used.
Measuring monotony in two-dimensional samples
NASA Astrophysics Data System (ADS)
Kachapova, Farida; Kachapov, Ilias
2010-04-01
This note introduces a monotony coefficient as a new measure of the monotone dependence in a two-dimensional sample. Some properties of this measure are derived. In particular, it is shown that the absolute value of the monotony coefficient for a two-dimensional sample is between |r| and 1, where r is the Pearson's correlation coefficient for the sample; that the monotony coefficient equals 1 for any monotone increasing sample and equals -1 for any monotone decreasing sample. This article contains a few examples demonstrating that the monotony coefficient is a more accurate measure of the degree of monotone dependence for a non-linear relationship than the Pearson's, Spearman's and Kendall's correlation coefficients. The monotony coefficient is a tool that can be applied to samples in order to find dependencies between random variables; it is especially useful in finding couples of dependent variables in a big dataset of many variables. Undergraduate students in mathematics and science would benefit from learning and applying this measure of monotone dependence.
Central Corneal Thickness Reproducibility among Ten Different Instruments.
Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco
2016-11-01
To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.
NASA Technical Reports Server (NTRS)
James, W. P. (Principal Investigator); Hill, J. M.; Bright, J. B.
1977-01-01
The author has identified the following significant results. Correlations between the satellite radiance values water color, Secchi disk visibility, turbidity, and attenuation coefficients were generally good. The residual was due to several factors including systematic errors in the remotely sensed data, errors, small time and space variations in the water quality measurements, and errors caused by experimental design. Satellite radiance values were closely correlated with the optical properties of the water.
A technique for estimating time of concentration and storage coefficient values for Illinois streams
Graf, Julia B.; Garklavs, George; Oberg, Kevin A.
1982-01-01
Values of the unit hydrograph parameters time of concentration (TC) and storage coefficient (R) can be estimated for streams in Illinois by a two-step technique developed from data for 98 gaged basins in the State. The sum of TC and R is related to stream length (L) and main channel slope (S) by the relation (TC + R)e = 35.2L0.39S-0.78. The variable R/(TC + R) is not significantly correlated with drainage area, slope, or length, but does exhibit a regional trend. Regional values of R/(TC + R) are used with the computed values of (TC + R)e to solve for estimated values of time of concentration (TCe) and storage coefficient (Re). The use of the variable R/(TC + R) is thought to account for variations in unit hydrograph parameters caused by physiographic variables such as basin topography, flood-plain development, and basin storage characteristics. (USGS)
Shen, Song; Jiang, Yan; Liu, Xiaochang; Luo, Yongkang; Gao, Liang
2015-08-01
In order to evaluate the effect of super chilling (-3 °C) and chilled (3 °C) storage on the quality of rainbow trout fillets, total volatile base nitrogen (TVB-N), drip loss, pH, electric conductivity (EC), total aerobic count (TAC), K and related values, adenosine triphosphate (ATP) and related compounds, color and sensory score were determined and correlation between these indicators were analyzed. According to the comprehensive evaluation of TAC, K value and sensory score, the limit for acceptability of rainbow trout fillets was 5 days at 3 °C and 11 days at -3 °C. Additionally, the correlation coefficients between TVB-N and other freshness indicators (TAC, K value, sensory score) were relatively low. TVB-N may be inadequate for evaluating freshness changes of rainbow trout fillets compared with other indicators. Among the K and related values, H value was a better freshness indicator in rainbow trout fillets during chilled and super chilling storage for its better correlation coefficients with other freshness indicators. Super chilling storage could extend the shelf life of rainbow trout fillets by 6 days compared to chilled storage.
Systematic bias of correlation coefficient may explain negative accuracy of genomic prediction.
Zhou, Yao; Vales, M Isabel; Wang, Aoxue; Zhang, Zhiwu
2017-09-01
Accuracy of genomic prediction is commonly calculated as the Pearson correlation coefficient between the predicted and observed phenotypes in the inference population by using cross-validation analysis. More frequently than expected, significant negative accuracies of genomic prediction have been reported in genomic selection studies. These negative values are surprising, given that the minimum value for prediction accuracy should hover around zero when randomly permuted data sets are analyzed. We reviewed the two common approaches for calculating the Pearson correlation and hypothesized that these negative accuracy values reflect potential bias owing to artifacts caused by the mathematical formulas used to calculate prediction accuracy. The first approach, Instant accuracy, calculates correlations for each fold and reports prediction accuracy as the mean of correlations across fold. The other approach, Hold accuracy, predicts all phenotypes in all fold and calculates correlation between the observed and predicted phenotypes at the end of the cross-validation process. Using simulated and real data, we demonstrated that our hypothesis is true. Both approaches are biased downward under certain conditions. The biases become larger when more fold are employed and when the expected accuracy is low. The bias of Instant accuracy can be corrected using a modified formula. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Consalvi, J. L.; Nmira, F.
2016-03-01
The main objective of this article is to quantify the influence of the soot absorption coefficient-Planck function correlation on radiative loss and flame structure in an oxygen-enhanced propane turbulent diffusion flame. Calculations were run with and without accounting for this correlation by using a standard k-ε model and the steady laminar flamelet model (SLF) coupled to a joint Probability Density Function (PDF) of mixture fraction, enthalpy defect, scalar dissipation rate, and soot quantities. The PDF transport equation is solved by using a Stochastic Eulerian Field (SEF) method. The modeling of soot production is carried out by using a flamelet-based semi-empirical acetylene/benzene soot model. Radiative heat transfer is modeled by using a wide band correlated-k model and turbulent radiation interactions (TRI) are accounted for by using the Optically-Thin Fluctuation Approximation (OTFA). Predicted soot volume fraction, radiant wall heat flux distribution and radiant fraction are in good agreement with the available experimental data. Model results show that soot absorption coefficient and Planck function are negatively correlated in the region of intense soot emission. Neglecting this correlation is found to increase significantly the radiative loss leading to a substantial impact on flame structure in terms of mean and rms values of temperature. In addition mean and rms values of soot volume fraction are found to be less sensitive to the correlation than temperature since soot formation occurs mainly in a region where its influence is low.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.
Two-Way Gene Interaction From Microarray Data Based on Correlation Methods
Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh
2016-01-01
Background Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. Objectives The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. Materials and Methods In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman’s rank correlation coefficient and Blomqvist’s measure, and compared them with Pearson’s correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson’s correlation, Spearman’s rank correlation, and Blomqvist’s coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Results Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist’s coefficient was not confirmed by visual methods. Conclusions Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data. PMID:27621916
Assessment of rate of drug release from oil vehicle using a rotating dialysis cell.
Larsen, D H; Fredholt, K; Larsen, C
2000-09-01
The rate constants for transfer of model compounds (naproxen and lidocaine) from oily vehicle (Viscoleo) to aqueous buffer phases were determined by use of the rotating dialysis cell. Release studies were done for the partly ionized compounds at several pH values. A correlation between the overall first-order rate constant related to attainment of equilibrium, k(obs), and the pH-dependent distribution coefficient, D, determined between oil vehicle and aqueous buffer was established according to the equation: logk(obs)=-0.71 logD-0.22 (k(obs) in h(-1)). Based on this correlation it was suggested that the rate constant of a weak electrolyte at a specified D value could be considered equal to the k(obs) value for a non-electrolyte possessing a partition coefficient, P(app), the magnitude of which was equal to D. Specific rate constants k(ow) and k(wo) were calculated from the overall rate constant and the pH-dependent distribution coefficient. The rate constant representing the transport from oily vehicle to aqueous phase, k(ow), was found to be significantly influenced by the magnitude of the partition coefficient P(app) according to: logk(ow)=-0.71 logP(app)-log(P(app)+1)-0.22 (k(ow) in h(-1)).
Measuring Perceived Educational Impact of a Resident-Led Research Newsletter.
Aftab, Awais; Lackamp, Jeanne; Cerny, Cathleen
2017-06-01
To determine the perceived educational impact of a resident-led psychiatry research newsletter ('Research Watch') on the psychiatry residents at the authors' residency program. An anonymous, voluntary paper questionnaire was distributed to all psychiatry residents at the program. The survey inquired about the degree of exposure (quantified as 'exposure index') and contribution to the newsletter. A set of questions asked residents to estimate how much of the improvement they attributed to the influence of the newsletter, rating the attribution between 0 and 100%, in the areas of interest in scholarly activities/research, knowledge of current psychiatric research, and participation in scholarly activities/research. The survey also inquired if the newsletter had any impact on their clinical practice. Of 29 residents in the program who received the survey, 27 (93%) responded. The percentage of residents reporting perceived non-zero impact of the newsletter on specific areas of improvement was as follows: interest in scholarly activities/research (44%), knowledge of current psychiatric research (48%), participation in scholarly activities/research (40%), and clinical practice (40%). Exposure index significantly and positively correlated with self-reported percentage attribution for knowledge (correlation coefficient 0.422, p value 0.028) and self-reported impact on clinical practice (correlation coefficient 0.660, p value 0.000), and degree of contribution significantly and positively correlated with self-reported percentage attribution for knowledge (correlation coefficient 0.488, p value 0.010). A resident-led research newsletter can have a positive perceived impact on the residents' interest, knowledge, and participation in research, as well as a positive perceived impact on clinical practice.
Is coverage a factor in non-Gaussianity of IMF parameters?
NASA Technical Reports Server (NTRS)
Ahluwalia, H. S.; Fikani, M. M.
1995-01-01
Recently, Feynman and Ruzmaikin (1994) showed that IMF parameters for the 1973 to 1990 period are not log-normally distributed as previously suggested by Burlaga and King (1979) for the data obtained over a shorter time period (1963-75). They studied the first four moments, namely: mean, variance, skewness, and kurtosis. For a Gaussian distribution, moments higher than the variance should vanish. In particular, Feynman and Ruzmaikin obtained very high values of kurtosis during some periods of their analysis. We note that the coverage for IMF parameters is very uneven for the period analyzed by them, ranging from less than 40% to greater than 80%. So a question arises as to whether the amount of coverage is a factor in their analysis. We decided to test this for the B(sub z) component of IMF, since it is an effective geoactive parameter for short term disturbances. Like them, we used 1-hour averaged data available on the Omnitape. We studied the scatter plots of the annual mean values of B(sub z)(nT) and its kurtosis versus the percent coverage for the year. We obtain a correlation coefficient of 0.48 and 0.42 respectively for the 1973-90 period. The probability for a chance occurrence of these correlation coefficients for 18 pair of points is less than 8%. As a rough measure of skewness, we determined the percent asymmetry between the areas of the histograms representing the distributions of the positive and the negative values of B(sub z) and studied its correlation with the coverage for the year. This analysis yields a correlation coefficient of 0.41 When we extended the analysis for the whole period for which IMF data are available (1963-93) the corresponding correlation coefficients are 0.59, 0.14, and 0.42. Our findings will be presented and discussed
Analysis of the wobbling effect in a lens-shaped body rotation
NASA Astrophysics Data System (ADS)
Kim, Minho
2017-03-01
We discuss the wobbling motion in a lens-shaped body rotation, focusing on the frequencies and the amplitude of nutation by filming the rotational motion and wobbling of the body. The friction coefficient of the surface is altered to examine its influence for two lenses with different curvature radii. MATLAB programs are developed to retrieve the Euler angles, which are graphed according to time. It is shown that the lens with a smaller curvature radius exhibits the wobbling effect in all cases, whereas the lens with a larger curvature radius shows such behaviour in limited circumstances. The study confirms that the friction coefficient has a negative linear correlation with the vertical axis declination amplitude with the R-squared value 0.878, showing that friction gives damping and causes smaller axis declination amplitudes. Negative linear correlation also exists with relation to the number of wobbles before the motion stops, where the R-squared value is 0.938, providing further evidence that friction and wobbling cause higher energy dissipation rates. The frequency of the wobbling motion only has a correlation with the curvature radius of the lens, showing no explicit correlation with the friction coefficient, with its R-squared value being 0.077. No losses of contact were observable in this motion. The overall process does not utilize particularly expensive apparatus and will be applicable for senior undergraduate students to experiment on and analyze the motion of a special situation regarding a rigid body that is both spinning and nutating.
Methods for recalibration of mass spectrometry data
Tolmachev, Aleksey V [Richland, WA; Smith, Richard D [Richland, WA
2009-03-03
Disclosed are methods for recalibrating mass spectrometry data that provide improvement in both mass accuracy and precision by adjusting for experimental variance in parameters that have a substantial impact on mass measurement accuracy. Optimal coefficients are determined using correlated pairs of mass values compiled by matching sets of measured and putative mass values that minimize overall effective mass error and mass error spread. Coefficients are subsequently used to correct mass values for peaks detected in the measured dataset, providing recalibration thereof. Sub-ppm mass measurement accuracy has been demonstrated on a complex fungal proteome after recalibration, providing improved confidence for peptide identifications.
Shang, Liu-Tong; Yang, Jia-Fei; Lu, Jing; Wang, Ting-Ting; Zhou, Ying; Xing, Xin-Bo; Wang, Xin-Kun; Yang, Shu-Hui; Hu, Ming-Yan
2017-10-20
To study the correlation of apparent diffusion coefficient (ADC) measured by diffusion-weighted magnetic resonance imaging (MRI) with the molecular subtypes and biological prognostic factors of invasive breast cancer masses. Breast MRI data (including dynamic enhanced and diffusion-weighted imaging) were collected from 64 patients with pathologically confirmed invasive breast cancer masses (a total of 69 lesions). The mean ADC values of the lesions were calculated and their correlations were analyzed with the 5 molecular subtypes of invasive breast cancer and the biological prognostic factors including estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor 2 (HER2), and Ki-67 index. The ADC values did not differ significantly among the 5 molecular subtypes of invasive breast cancer masses (P>0.05) or among lesions with different ER, PR, or HER2 status (P>0.05). The mean ADC values were significantly higher in Ki-67-positive lesions than in the negative lesions (P=0.023 and negatively correlated with the expressions of Ki-67 (r=-0.249). ADC value can not be used to identify the molecular subtypes of invasive breast cancer masses or to evaluate the biological prognosis of the lesions, but its correlation with Ki-67 expression may help in prognostic evaluation and guiding clinical therapy of the tumors.
NASA Astrophysics Data System (ADS)
da Silva, Marcus Fernandes; de Area Leão Pereira, Éder Johnson; da Silva Filho, Aloisio Machado; de Castro, Arleys Pereira Nunes; Miranda, José Garcia Vivas; Zebende, Gilney Figueira
2016-07-01
In this paper we quantify the cross-correlation between the adjusted closing index of the G7 countries, by their Gross Domestic Product (nominal). For this purpose we consider the 2008 financial crisis. Thus, we intend to observe the impact of the 2008 crisis by applying the DCCA cross-correlation coefficient ρDCCA between these countries. As an immediate result we observe that there is a positive cross-correlation between the index, and this coefficient changes with time between weak, medium, and strong values. If we compare the pre-crisis period (before 2008) with the post-crisis period (after 2008), it is noticed that ρDCCA changes its value. From these facts, we propose to study the contagion (interdependence) effect from this change by a new variable, ΔρDCCA. Thus, we present new findings for the 2008 crisis between the members of the G7.
Kim, Mimi; Kang, Tae Wook; Kim, Young Kon; Kim, Seong Hyun; Kwon, Wooil; Ha, Sang Yun; Ji, Sang A
2016-03-01
To evaluate the correlation between grade of pancreatic neuroendocrine tumours (pNETs) based on the 2010 World Health Organization (WHO) classification and the apparent diffusion coefficient (ADC), and to assess whether the ADC value and WHO classification can predict recurrence-free survival (RFS) after surgery for pNETs. This retrospective study was approved by the Institutional Review Board. The requirement for informed consent was waived. Between March 2009 and November 2014, forty-nine patients who underwent magnetic resonance (MR) imaging with diffusion-weighted image and subsequent surgery for single pNETs were included. Correlations among qualitative MR imaging findings, quantitative ADC values, and WHO classifications were assessed. An ordered logistic regression test was used to control for tumour size as a confounding factor. The association between ADC value (or WHO classification) and RFS was analysed. All tumors (n=49) were classified as low- (n=29, grade 1), intermediate- (n=17, grade 2), and high-grade (n=3, grade 3), respectively. The mean ADC of pNETs was moderately negatively correlated with WHO classification before and after adjustment for tumour size (ρ=-0.64, p<0.001 and ρ=-0.55, p=0.001 respectively). RFS was significantly associated with WHO classification (p=0.007), but not with the ADC value (p=0.569). The ADC value of pNETs is moderately correlated with WHO tumour grade, regardless of tumour size. However, the WHO tumour classification of pNET may be more suitable for predicting RFS than the ADC value. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Nanda, Sunil Kumar; Ray, Lopamudra; Dinakaran, Asha
2015-02-01
Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be measured in arterial blood within 5 min. This study was done to study the agreement of arterial sodium and arterial potassium with venous sodium and venous potassium levels. Venous sodium and venous potassium levels and arterial sodium and arterial potassium levels were analysed on 206 patient samples admitted to Intensive Care Unit (ICU). The venous values were compared with the arterial values for correlation. Venous sodium was compared with arterial sodium by spearman correlation. Venous potassium was compared with arterial potassium by pearson correlation. The mean value of arterial sodium was 134 and venous sodium was 137. The mean value of arterial potassium was 3.6 and venous potassium was 4.1. The correlation coefficient obtained for sodium was 0.787 and correlation coefficient obtained for potassium was 0.701. There was positive correlation of arterial sodium and arterial potassium with venous sodium and venous potassium indicating agreement between the parameters. Arterial sodium and arterial potassium can be used instead of venous sodium and venous potassium levels in management of critically ill patients.
Ji, Changfeng; Zhang, Qinglei; Guan, Wenxian; Guo, Tingting; Chen, Ling; Liu, Song; He, Jian; Zhou, Zhengyang
2017-07-25
To explore the role of intravoxel incoherent motion (IVIM) magnetic resonance (MR) imaging in evaluating human epidermal growth factor receptor 2 (HER2) status of gastric cancers preoperatively. The apparent diffusion coefficient (ADC) and pure diffusion coefficient (D) values correlated positively with HER2 scores of gastric cancers significantly (r = 0.276, P = 0.048; r = 0.481, P < 0.001, respectively). The ADC and D values of HER2 positive gastric cancers were significantly higher than those of HER2 negative tumors (P = 0.033, 0.007, respectively). With a cut-off value of 1.321 and 1.123 × 10-3 mm2/sec, the ADC and D values could distinguish HER2 positive gastric cancers from HER2 negative ones with an area under the curve of 0.733 and 0.762, respectively (P = 0.023, 0.011, respectively). Fifty-three patients with gastric cancers underwent IVIM MR imaging preoperatively. The values of ADC, D, pseudo diffusion coefficient (D*) and perfusion related fraction (f) of the lesions were obtained. Partial correlation test including tumor volume was performed to analyze correlations between IVIM values and HER2 scores excluding the impact of tumor size. IVIM parameters of gastric cancers with different HER2 status were compared using independent samples t test. Diagnostic performance of IVIM parameters in distinguishing HER2 positive gastric cancers from negative ones was tested with receiver operating characteristic analysis. We confirmed the feasibility of IVIM MR imaging in preoperative assessment of HER2 status of gastric cancers, which might make up the shortfall of biopsy and facilitate personalized treatment for patients with gastric cancers.
The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.
Erceg, David N; Dieli-Conwright, Christina M; Rossuello, Amerigo E; Jensky, Nicole E; Sun, Stephanie; Schroeder, E Todd
2010-05-01
Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Obayashi, Takeshi; Kinoshita, Kengo
2013-01-01
Gene coexpression analysis is a powerful approach to elucidate gene function. We have established and developed this approach using vast amount of publicly available gene expression data measured by microarray techniques. The coexpressed genes are used to estimate gene function of the guide gene or to construct gene coexpression networks. In the case to construct gene networks, researchers should introduce an arbitrary threshold of gene coexpression, because gene coexpression value is continuous value. In the viewpoint to introduce common threshold of gene coexpression, we previously reported rank of Pearson's correlation coefficient (PCC) is more useful than the original PCC value. In this manuscript, we re-assessed the measure of gene coexpression to construct gene coexpression network, and found that mutual rank (MR) of PCC showed better performance than rank of PCC and the original PCC in low false positive rate.
Structural features that predict real-value fluctuations of globular proteins.
Jamroz, Michal; Kolinski, Andrzej; Kihara, Daisuke
2012-05-01
It is crucial to consider dynamics for understanding the biological function of proteins. We used a large number of molecular dynamics (MD) trajectories of nonhomologous proteins as references and examined static structural features of proteins that are most relevant to fluctuations. We examined correlation of individual structural features with fluctuations and further investigated effective combinations of features for predicting the real value of residue fluctuations using the support vector regression (SVR). It was found that some structural features have higher correlation than crystallographic B-factors with fluctuations observed in MD trajectories. Moreover, SVR that uses combinations of static structural features showed accurate prediction of fluctuations with an average Pearson's correlation coefficient of 0.669 and a root mean square error of 1.04 Å. This correlation coefficient is higher than the one observed in predictions by the Gaussian network model (GNM). An advantage of the developed method over the GNMs is that the former predicts the real value of fluctuation. The results help improve our understanding of relationships between protein structure and fluctuation. Furthermore, the developed method provides a convienient practial way to predict fluctuations of proteins using easily computed static structural features of proteins. Copyright © 2012 Wiley Periodicals, Inc.
Structural features that predict real-value fluctuations of globular proteins
Jamroz, Michal; Kolinski, Andrzej; Kihara, Daisuke
2012-01-01
It is crucial to consider dynamics for understanding the biological function of proteins. We used a large number of molecular dynamics trajectories of non-homologous proteins as references and examined static structural features of proteins that are most relevant to fluctuations. We examined correlation of individual structural features with fluctuations and further investigated effective combinations of features for predicting the real-value of residue fluctuations using the support vector regression. It was found that some structural features have higher correlation than crystallographic B-factors with fluctuations observed in molecular dynamics trajectories. Moreover, support vector regression that uses combinations of static structural features showed accurate prediction of fluctuations with an average Pearson’s correlation coefficient of 0.669 and a root mean square error of 1.04 Å. This correlation coefficient is higher than the one observed for the prediction by the Gaussian network model. An advantage of the developed method over the Gaussian network models is that the former predicts the real-value of fluctuation. The results help improve our understanding of relationships between protein structure and fluctuation. Furthermore, the developed method provides a convienient practial way to predict fluctuations of proteins using easily computed static structural features of proteins. PMID:22328193
Sabetghadam, Samaneh; Ahmadi-Givi, Farhang
2014-01-01
Light extinction, which is the extent of attenuation of light signal for every distance traveled by light in the absence of special weather conditions (e.g., fog and rain), can be expressed as the sum of scattering and absorption effects of aerosols. In this paper, diurnal and seasonal variations of the extinction coefficient are investigated for the urban areas of Tehran from 2007 to 2009. Cases of visibility impairment that were concurrent with reports of fog, mist, precipitation, or relative humidity above 90% are filtered. The mean value and standard deviation of daily extinction are 0.49 and 0.39 km(-1), respectively. The average is much higher than that in many other large cities in the world, indicating the rather poor air quality over Tehran. The extinction coefficient shows obvious diurnal variations in each season, with a peak in the morning that is more pronounced in the wintertime. Also, there is a very slight increasing trend in the annual variations of atmospheric extinction coefficient, which suggests that air quality has regressed since 2007. The horizontal extinction coefficient decreased from January to July in each year and then increased between July and December, with the maximum value in the winter. Diurnal variation of extinction is often associated with small values for low relative humidity (RH), but increases significantly at higher RH. Annual correlation analysis shows that there is a positive correlation between the extinction coefficient and RH, CO, PM10, SO2, and NO2 concentration, while negative correlation exists between the extinction and T, WS, and O3, implying their unfavorable impact on extinction variation. The extinction budget was derived from multiple regression equations using the regression coefficients. On average, 44% of the extinction is from suspended particles, 3% is from air molecules, about 5% is from NO2 absorption, 0.35% is from RH, and approximately 48% is unaccounted for, which may represent errors in the data as well as contribution of other atmospheric constituents omitted from the analysis. Stronger regression equation is achieved in the summer, meaning that the extinction is more predictable in this season using pollutant concentrations.
Statistical test for ΔρDCCA cross-correlation coefficient
NASA Astrophysics Data System (ADS)
Guedes, E. F.; Brito, A. A.; Oliveira Filho, F. M.; Fernandez, B. F.; de Castro, A. P. N.; da Silva Filho, A. M.; Zebende, G. F.
2018-07-01
In this paper we propose a new statistical test for ΔρDCCA, Detrended Cross-Correlation Coefficient Difference, a tool to measure contagion/interdependence effect in time series of size N at different time scale n. For this proposition we analyzed simulated and real time series. The results showed that the statistical significance of ΔρDCCA depends on the size N and the time scale n, and we can define a critical value for this dependency in 90%, 95%, and 99% of confidence level, as will be shown in this paper.
The Effects of Methods of Imputation for Missing Values on the Validity and Reliability of Scales
ERIC Educational Resources Information Center
Cokluk, Omay; Kayri, Murat
2011-01-01
The main aim of this study is the comparative examination of the factor structures, corrected item-total correlations, and Cronbach-alpha internal consistency coefficients obtained by different methods used in imputation for missing values in conditions of not having missing values, and having missing values of different rates in terms of testing…
Cluster structure in the correlation coefficient matrix can be characterized by abnormal eigenvalues
NASA Astrophysics Data System (ADS)
Nie, Chun-Xiao
2018-02-01
In a large number of previous studies, the researchers found that some of the eigenvalues of the financial correlation matrix were greater than the predicted values of the random matrix theory (RMT). Here, we call these eigenvalues as abnormal eigenvalues. In order to reveal the hidden meaning of these abnormal eigenvalues, we study the toy model with cluster structure and find that these eigenvalues are related to the cluster structure of the correlation coefficient matrix. In this paper, model-based experiments show that in most cases, the number of abnormal eigenvalues of the correlation matrix is equal to the number of clusters. In addition, empirical studies show that the sum of the abnormal eigenvalues is related to the clarity of the cluster structure and is negatively correlated with the correlation dimension.
Stefl, Martin; Kułakowska, Anna; Hof, Martin
2009-08-05
A new (to our knowledge) robust approach for the determination of lateral diffusion coefficients of weakly bound proteins is applied for the phosphatidylserine specific membrane interaction of bovine prothrombin. It is shown that z-scan fluorescence correlation spectroscopy in combination with pulsed interleaved dual excitation allows simultaneous monitoring of the lateral diffusion of labeled protein and phospholipids. Moreover, from the dependencies of the particle numbers on the axial sample positions at different protein concentrations phosphatidylserine-dependent equilibrium dissociation constants are derived confirming literature values. Increasing the amount of membrane-bound prothrombin retards the lateral protein and lipid diffusion, indicating coupling of both processes. The lateral diffusion coefficients of labeled lipids are considerably larger than the simultaneously determined lateral diffusion coefficients of prothrombin, which contradicts findings reported for the isolated N-terminus of prothrombin.
Investigation into the Effects of Textural Properties on Cuttability Performance of a Chisel Tool
NASA Astrophysics Data System (ADS)
Tumac, Deniz; Copur, Hanifi; Balci, Cemal; Er, Selman; Avunduk, Emre
2018-04-01
The main objective of this study is to investigate the effect of textural properties of stones on cutting performance of a standard chisel tool. Therewithal, the relationships between textural properties and cutting performance parameters and physical and mechanical properties were statistically analyzed. For this purpose, physical and mechanical property tests and mineralogical and petrographic analyses were carried out on eighteen natural stone samples, which can be grouped into three fundamentally different geological origins, i.e., metamorphic, igneous, and sedimentary. Then, texture coefficient analyses were performed on the samples. To determine the cuttability of the stones; the samples were cut with a portable linear cutting machine using a standard chisel tool at different depths of cut in unrelieved (non-interactive) cutting mode. The average and maximum forces (normal and cutting) and specific energy were measured, and the obtained values were correlated with texture coefficient, packing weighting, and grain size. With reference to the relation between depth of cut and cutting performance of the chisel tool for three types of natural stone groups, specific energy decreases with increasing depth of cut, and cutting forces increase in proportion to the depth of cut. The same is observed for the relationship between packing weighting and both of specific energy and cutter forces. On the other hand, specific energy and the forces decrease while grain size increases. Based on the findings of the present study, texture coefficient has strong correlation with specific energy. Generally, the lower depth of cut values in cutting tests shows higher and more reliable correlations with texture coefficient than the increased depth of cut. The results of cutting tests show also that, at a lower depth of cut (less than 1.5 mm), even stronger correlations can be observed between texture coefficient and cutting performance. Experimental studies indicate that cutting performance of chisel tools can be predicted based on texture coefficients of the natural stones.
2013-01-01
Background The synthesis of information across microarray studies has been performed by combining statistical results of individual studies (as in a mosaic), or by combining data from multiple studies into a large pool to be analyzed as a single data set (as in a melting pot of data). Specific issues relating to data heterogeneity across microarray studies, such as differences within and between labs or differences among experimental conditions, could lead to equivocal results in a melting pot approach. Results We applied statistical theory to determine the specific effect of different means and heteroskedasticity across 19 groups of microarray data on the sign and magnitude of gene-to-gene Pearson correlation coefficients obtained from the pool of 19 groups. We quantified the biases of the pooled coefficients and compared them to the biases of correlations estimated by an effect-size model. Mean differences across the 19 groups were the main factor determining the magnitude and sign of the pooled coefficients, which showed largest values of bias as they approached ±1. Only heteroskedasticity across the pool of 19 groups resulted in less efficient estimations of correlations than did a classical meta-analysis approach of combining correlation coefficients. These results were corroborated by simulation studies involving either mean differences or heteroskedasticity across a pool of N > 2 groups. Conclusions The combination of statistical results is best suited for synthesizing the correlation between expression profiles of a gene pair across several microarray studies. PMID:23822712
Quantifying expert diagnosis variability when grading tumor-infiltrating lymphocytes
NASA Astrophysics Data System (ADS)
Toro, Paula; Corredor, Germán.; Wang, Xiangxue; Arias, Viviana; Velcheti, Vamsidhar; Madabhushi, Anant; Romero, Eduardo
2017-11-01
Tumor-infiltrating lymphocytes (TILs) have proved to play an important role in predicting prognosis, survival, and response to treatment in patients with a variety of solid tumors. Unfortunately, currently, there are not a standardized methodology to quantify the infiltration grade. The aim of this work is to evaluate variability among the reports of TILs given by a group of pathologists who examined a set of digitized Non-Small Cell Lung Cancer samples (n=60). 28 pathologists answered a different number of histopathological images. The agreement among pathologists was evaluated by computing the Kappa index coefficient and the standard deviation of their estimations. Furthermore, TILs reports were correlated with patient's prognosis and survival using the Pearson's correlation coefficient. General results show that the agreement among experts grading TILs in the dataset is low since Kappa values remain below 0.4 and the standard deviation values demonstrate that in none of the images there was a full consensus. Finally, the correlation coefficient for each pathologist also reveals a low association between the pathologists' predictions and the prognosis/survival data. Results suggest the need of defining standardized, objective, and effective strategies to evaluate TILs, so they could be used as a biomarker in the daily routine.
Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano
2017-01-01
Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329
Accuracy of Transcutaneous CO2 Values Compared With Arterial and Capillary Blood Gases.
Lambert, Laura L; Baldwin, Melissa B; Gonzalez, Cruz Velasco; Lowe, Gary R; Willis, J Randy
2018-05-08
Transcutaneous monitors are utilized to monitor a patient's respiratory status. Some patients have similar values when comparing transcutaneous carbon dioxide ( P tcCO 2 ) values with blood gas analysis, whereas others show extreme variability. A retrospective review of data was performed to determine how accurately P tcCO 2 correlated with CO 2 values obtained by arterial blood gas (ABG) or capillary blood gas. To determine whether P tcCO 2 values correlated with ABG or capillary blood gas values, subjects' records were retrospectively reviewed. Data collected included the P tcCO 2 value at the time of blood gas procurement and the ABG or capillary blood gas P CO 2 value. Agreement of pairs of methods (ABG vs P tcCO 2 and capillary blood gas vs P tcCO 2 ) was assessed with the Bland-Altman approach with limits of agreement estimated with a mixed model to account for serial measurements per subject. A total of 912 pairs of ABG/ P tcCO 2 values on 54 subjects and 307 pairs of capillary blood gas/ P tcCO 2 values on 34 subjects were analyzed. The P CO 2 range for ABG was 24-106 mm Hg, and P tcCO 2 values were 27-133 mm Hg. The P CO 2 range for capillary blood gas was 29-108 mm Hg, and P tcCO 2 values were 30-103 mm Hg. For ABG/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.82, 95% CI was 0.80-0.84, and P was <.001. For capillary blood gas/ P tcCO 2 comparisons, the Pearson correlation coefficient was 0.77, 95% CI was 0.72-0.81, and P was <.001. For ABG/ P tcCO 2 , the estimated difference ± SD was -6.79 t± 7.62 mm Hg, and limits of agreement were -22.03 to 8.45. For capillary blood gas/ P tcCO 2 , the estimated difference ± SD was -1.61 ± 7.64 mm Hg, and limits of agreement were -16.88 to 13.66. The repeatability coefficient was about 30 mm Hg. Based on these data, capillary blood gas comparisons showed less variation and a slightly lower correlation with P tcCO 2 than did ABG comparisons. After accounting for serial measurements per patient, due to the wide limits of agreement and poor repeatability, the utility of relying on P tcCO 2 readings for this purpose is questionable. Copyright © 2018 by Daedalus Enterprises.
[Fractal dimension--a new EEG-based method of assessing the depth of anaesthesia].
Willand, Monika; Rudner, Robert; Olejarczyk, Elzbieta; Wartak, Magdalena; Marciniak, Radosław; Stasiowski, Michał; Byrczek, Tomasz; Jałowiecki, Przemysław
2008-01-01
It has been suggested that analysis of the EEG signal using the fractal dimension method may be useful for assessment of depth of anaesthesia. Thirty ASA I and II patients, scheduled for elective surgery under general anaesthesia were induced with midazolam, fentanyl and propofol and paralyzed with rocuronium or cis-atracurium. Clinical signs of the depth of anaesthesia were classified to one of five OAA/S levels. Standard vital parameters were observed and brain electrical activity was measured using the bispectral index (BIS) and burst suppression ratio (BSR). The EEG signal was recorded and processed postoperatively to calculate Higuchi's fractal dimension (FD). The latter was presented as a derivative: (D(F)-1) x 100. Mean correlation coefficients between OAA/S scale levels, and BIS and (D(F)-1) x 100 values, were respectively: 0.749+/-0.172 and 0.753+/-0.220. In 28 (93.3%) patients, BIS correlated well with FD (r=0.63+/-0.33). In twenty cases, burst suppression occurred and the correlation coefficient between BIS and DF was much lower (r=0.5860+/-3650), when compared to the group of 10 patients in which no burst suppression was detected (r=0.711+/-0.251). Appropriate correction was made using the following formula: D(FK)=D(F)-(D(F) x BSR). The mean correlation coefficient between BIS values and D(FK) in the BS group was r=0.629+/-0.331. In all cases, the mean correlation coefficient between (D(F)-1) x 100 and BIS was r=0.661+/-0.307 (p<0.001). The fractal dimension method can be regarded as equal to BIS for assessment of depth of anaesthesia.
de Winter, Joost C F; Gosling, Samuel D; Potter, Jeff
2016-09-01
The Pearson product–moment correlation coefficient ( r p ) and the Spearman rank correlation coefficient ( r s ) are widely used in psychological research. We compare r p and r s on 3 criteria: variability, bias with respect to the population value, and robustness to an outlier. Using simulations across low (N = 5) to high (N = 1,000) sample sizes we show that, for normally distributed variables, r p and r s have similar expected values but r s is more variable, especially when the correlation is strong. However, when the variables have high kurtosis, r p is more variable than r s . Next, we conducted a sampling study of a psychometric dataset featuring symmetrically distributed data with light tails, and of 2 Likert-type survey datasets, 1 with light-tailed and the other with heavy-tailed distributions. Consistent with the simulations, r p had lower variability than r s in the psychometric dataset. In the survey datasets with heavy-tailed variables in particular, r s had lower variability than r p , and often corresponded more accurately to the population Pearson correlation coefficient ( R p ) than r p did. The simulations and the sampling studies showed that variability in terms of standard deviations can be reduced by about 20% by choosing r s instead of r p . In comparison, increasing the sample size by a factor of 2 results in a 41% reduction of the standard deviations of r s and r p . In conclusion, r p is suitable for light-tailed distributions, whereas r s is preferable when variables feature heavy-tailed distributions or when outliers are present, as is often the case in psychological research. PsycINFO Database Record (c) 2016 APA, all rights reserved
Estimated Accuracy of Three Common Trajectory Statistical Methods
NASA Technical Reports Server (NTRS)
Kabashnikov, Vitaliy P.; Chaikovsky, Anatoli P.; Kucsera, Tom L.; Metelskaya, Natalia S.
2011-01-01
Three well-known trajectory statistical methods (TSMs), namely concentration field (CF), concentration weighted trajectory (CWT), and potential source contribution function (PSCF) methods were tested using known sources and artificially generated data sets to determine the ability of TSMs to reproduce spatial distribution of the sources. In the works by other authors, the accuracy of the trajectory statistical methods was estimated for particular species and at specified receptor locations. We have obtained a more general statistical estimation of the accuracy of source reconstruction and have found optimum conditions to reconstruct source distributions of atmospheric trace substances. Only virtual pollutants of the primary type were considered. In real world experiments, TSMs are intended for application to a priori unknown sources. Therefore, the accuracy of TSMs has to be tested with all possible spatial distributions of sources. An ensemble of geographical distributions of virtual sources was generated. Spearman s rank order correlation coefficient between spatial distributions of the known virtual and the reconstructed sources was taken to be a quantitative measure of the accuracy. Statistical estimates of the mean correlation coefficient and a range of the most probable values of correlation coefficients were obtained. All the TSMs that were considered here showed similar close results. The maximum of the ratio of the mean correlation to the width of the correlation interval containing the most probable correlation values determines the optimum conditions for reconstruction. An optimal geographical domain roughly coincides with the area supplying most of the substance to the receptor. The optimal domain s size is dependent on the substance decay time. Under optimum reconstruction conditions, the mean correlation coefficients can reach 0.70 0.75. The boundaries of the interval with the most probable correlation values are 0.6 0.9 for the decay time of 240 h and 0.5 0.95 for the decay time of 12 h. The best results of source reconstruction can be expected for the trace substances with a decay time on the order of several days. Although the methods considered in this paper do not guarantee high accuracy they are computationally simple and fast. Using the TSMs in optimum conditions and taking into account the range of uncertainties, one can obtain a first hint on potential source areas.
Shitzer, Avraham
2006-03-01
The wind-chill index (WCI), developed in Antarctica in the 1940s and recently updated by the weather services in the USA and Canada, expresses the enhancement of heat loss in cold climates from exposed body parts, e.g., face, due to wind. The index provides a simple and practical means for assessing the thermal effects of wind on humans outdoors. It is also used for indicating weather conditions that may pose adverse risks of freezing at subfreezing environmental temperatures. Values of the WCI depend on a number of parameters, i.e, temperatures, physical properties of the air, wind speed, etc., and on insolation and evaporation. This paper focuses on the effects of various empirical correlations used in the literature for calculating the convective heat transfer coefficients between humans and their environment. Insolation and evaporation are not included in the presentation. Large differences in calculated values among these correlations are demonstrated and quantified. Steady-state wind-chill-equivalent temperatures (WCETs) are estimated by a simple, one-dimensional heat-conducting hollow-cylindrical model using these empirical correlations. Partial comparison of these values with the published "new" WCETs is presented. The variability of the estimated WCETs, due to different correlations employed to calculate them, is clearly demonstrated. The results of this study clearly suggest the need for establishing a "gold standard" for estimating convective heat exchange between exposed body elements and the cold and windy environment. This should be done prior to the introduction and adoption of further modifications to WCETs and indices. Correlations to estimate the convective heat transfer coefficients between exposed body parts of humans in windy and cold environments influence the WCETs and need to be standardized.
NASA Astrophysics Data System (ADS)
Shitzer, Avraham
2006-03-01
The wind-chill index (WCI), developed in Antarctica in the 1940s and recently updated by the weather services in the USA and Canada, expresses the enhancement of heat loss in cold climates from exposed body parts, e.g., face, due to wind. The index provides a simple and practical means for assessing the thermal effects of wind on humans outdoors. It is also used for indicating weather conditions that may pose adverse risks of freezing at subfreezing environmental temperatures. Values of the WCI depend on a number of parameters, i.e, temperatures, physical properties of the air, wind speed, etc., and on insolation and evaporation. This paper focuses on the effects of various empirical correlations used in the literature for calculating the convective heat transfer coefficients between humans and their environment. Insolation and evaporation are not included in the presentation. Large differences in calculated values among these correlations are demonstrated and quantified. Steady-state wind-chill-equivalent temperatures (WCETs) are estimated by a simple, one-dimensional heat-conducting hollow-cylindrical model using these empirical correlations. Partial comparison of these values with the published “new” WCETs is presented. The variability of the estimated WCETs, due to different correlations employed to calculate them, is clearly demonstrated. The results of this study clearly suggest the need for establishing a “gold standard” for estimating convective heat exchange between exposed body elements and the cold and windy environment. This should be done prior to the introduction and adoption of further modifications to WCETs and indices. Correlations to estimate the convective heat transfer coefficients between exposed body parts of humans in windy and cold environments influence the WCETs and need to be standardized.
Analysis of Manning’s and Drag Coefficients for Flexible Submerged Vegetation
NASA Astrophysics Data System (ADS)
Yusof, Khamaruzaman Wan; Mujahid Muhammad, Muhammad; Mustafa, Muhammad Raza Ul; Azazi Zakaria, Nor; Gahani, Aminuddin Ab.
2017-06-01
Accurate determination of flow resistance is of great significance in modelling of open channels that will convey water efficiently. Although, resistance or drag induced by vegetation have been systematically studied for several decades, estimating of the resistance remain as a challenge. This is because most of previous studies use artificial vegetation to investigate flow - vegetation interactions. To overcome this, the present study evaluates the vegetation resistance in terms of Manning’s roughness coefficient and drag coefficient using a natural flexible vegetation (cow grass) under submerged condition. From the experimental result obtained, it was observed that the Manning’s and drag coefficients decreased with the increasing in average velocity. Also, graphical relationship between Manning’s coefficient, n and drag coefficient, CD has been developed with R2 = 0.9465, which indicate that there exist a strong correlation between n and CD, and one can use the proposed graphical model to predict the n - values corresponding to the CD - values.
[Comparison of refraction with or without cycloplegia using Retinomax® or Plusoptix® devices].
Bui Quoc, E; Guilmin Crepon, S; Tinguely, S; Lavallee, G; Busquet, G; Angot, M; Vera, L
2017-03-01
To evaluate the refraction in children measured with Plusoptix ® without cycloplegia vs. Retinomax ® apparatus with cycloplegia. Measure of refraction with Plusoptix ® in children>1year old referred for systematic vision screening, then measurement after cycloplegia with cyclopentolate by the Retinomax ® device. Thirty-three children were included, i.e. 66eyes. Mean age was 40.7months (minimum 12; maximum 114). The Spearman correlation coefficient for the spherical equivalent was 0.52 (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=moderate correlation). The Spearman correlation coefficient was 0.73 for astigmatism (Plusoptix ® vs. Retinomax ® comparison; P<0.0001=strong correlation). The Plusoptix ® sensitivity for measurement of refraction was 57%, 43% and 43% respectively for spherical equivalent, sphere and astigmatism. The correlation of astigmatism values is strong, whereas the correlation of sphere values is moderate. Plusoptix ® seems to be unable to measure the exact refraction, because there is too large a dispersion of refraction measurements with Plusoptix ® , compared to the exact refraction measured with the Retinomax ® . Moreover, the sensitivity of Plusoptix ® is low. Cycloplegic refraction remains indispensable in children. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K
2016-01-01
Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.
Kikuchi, Ken; Shigihara, Takeshi; Hashimoto, Yuko; Miyajima, Masayuki; Haga, Nobuhiro; Kojima, Yoshiyuki; Shishido, Fumio
2017-01-01
Abstract AIMS: To evaluate the relationship between the apparent diffusion coefficient (ADC) value for bladder cancer and the recurrence/progression risk of post-transurethral resection (TUR). METHODS: Forty-one patients with initial and non-muscle-invasive bladder cancer underwent MRI from 2009 to 2012. Two radiologists measured ADC values. A pathologist calculated the recurrence/progression scores, and risk was classified based on the scores. Pearson’s correlation was used to analyze the correlations of ADC value with each score and with each risk group, and the optimal cut-off value was established based on receiver operating characteristic (ROC) curve analysis. Furthermore, the relationship between actual recurrence / progression of cases and ADC values was examined by Unpaird U test. RESULTS: There were significant correlations between ADC value and the recurrence score as well as the progression score (P<0.01, P<0.01, respectively). There were also significant correlations between ADC value and the recurrence risk group as well as progression risk group (P=0.042, P<0.01, respectively). The ADC cut-off value on ROC analysis was 1.365 (sensitivity 100%; specificity 97.4%) for the low and intermediate recurrence risk groups, 1.024 (sensitivity 47.4%; specificity 100%) for the intermediate and high recurrence risk groups, 1.252 (sensitivity 83.3%; specificity 81.3%) for the low and intermediate progression risk groups, and 0.955 (sensitivity 87.5%; specificity 63.2%) between the intermediate and high progression risk groups. The difference between the ADC values of the recurrence and nonrecurrence group in Unpaired t test was significant (P<0.05). CONCLUSION: ADC on MRI in bladder cancer could potentially be useful, non-invasive measurement for estimating the risks of recurrence and progression. PMID:28680010
NASA Astrophysics Data System (ADS)
Zhao, Siqi; Zhang, Guanglong; Xia, Shuwei; Yu, Liangmin
2018-06-01
As a group of diversified frameworks, quinazolin derivatives displayed a broad field of biological functions, especially as anticancer. To investigate the quantitative structure-activity relationship, 3D-QSAR models were generated with 24 quinazolin scaffold molecules. The experimental and predicted pIC50 values for both training and test set compounds showed good correlation, which proved the robustness and reliability of the generated QSAR models. The most effective CoMFA and CoMSIA were obtained with correlation coefficient r 2 ncv of 1.00 (both) and leave-one-out coefficient q 2 of 0.61 and 0.59, respectively. The predictive abilities of CoMFA and CoMSIA were quite good with the predictive correlation coefficients ( r 2 pred ) of 0.97 and 0.91. In addition, the statistic results of CoMFA and CoMSIA were used to design new quinazolin molecules.
VizieR Online Data Catalog: Fermi/GBM GRB time-resolved spectral catalog (Yu+, 2016)
NASA Astrophysics Data System (ADS)
Yu, H.-F.; Preece, R. D.; Greiner, J.; Bhat, P. N.; Bissaldi, E.; Briggs, M. S.; Cleveland, W. H.; Connaughton, V.; Goldstein, A.; von Kienlin; A.; Kouveliotou, C.; Mailyan, B.; Meegan, C. A.; Paciesas, W. S.; Rau, A.; Roberts, O. J.; Veres, P.; Wilson-Hodge, C.; Zhang, B.-B.; van Eerten, H. J.
2016-01-01
Time-resolved spectral analysis results of BEST models: for each spectrum GRB name using the Fermi GBM trigger designation, spectrum number within individual burst, start time Tstart and end time Tstop for the time bin, BEST model, best-fit parameters of the BEST model, value of CSTAT per degrees of freedom, 10keV-1MeV photon and energy flux are given. Ep evolutionary trends: for each burst GRB name, number of spectra with Ep, Spearman's Rank Correlation Coefficients between Ep_ and photon flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficients between Ep and energy flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficient between Ep and time and 90%, 95%, and 99% confidence intervals, trends as determined by computer for 90%, 95%, and 99% confidence intervals, trends as determined by human eyes are given. (2 data files).
The Free-Free Absorption Coefficients of the Negative Helium Ion
NASA Astrophysics Data System (ADS)
John, T. L.
1994-08-01
Free-free absorption coefficients of the negative helium ion are calculated by a phaseshift approximation, using continuum data that accurately account for electron-atom correlation and polarization. The approximation is considered to yield results within a few per cent of numerical values for wavelengths greater than 1 m, over the temperature range 1400-10080 K. These coefficients are expected to give the best current estimates of He - continuous absorption. Key words: atomic data - atomic processes - stars: atmospheres - infrared: general.
Velasco-Barona, Cecilio; Cervantes-Coste, Guadalupe; Mendoza-Schuster, Erick; Corredor-Ortega, Claudia; Casillas-Chavarín, Nadia L; Silva-Moreno, Alejandro; Garza-León, Manuel; Gonzalez-Salinas, Roberto
2018-06-01
To compare the biometric measurements obtained from the Verion Image-Guided System to those obtained by auto-refracto-keratometer in normal eyes. This is a prospective, observational, comparative study conducted at the Asociación para Evitar la Ceguera en México I.A.P., Mexico. Three sets of keratometry measurements were obtained using the image-guided system to assess the coefficient of variation, the within-subject standard deviation and intraclass correlation coefficient (ICC). A paired Student t test was used to assess statistical significance between the Verion and the auto-refracto-keratometer. A Pearson's correlation coefficient (r) was obtained for all measurements, and the level of agreement was verified using Bland-Altman plots. The right eyes of 73 patients were evaluated by each platform. The Verion coefficient of variation was 0.3% for the flat and steep keratometry, with the ICC being greater than 0.9 for all parameters measured. Paired t test showed statistically significant differences between groups (P = 0.0001). A good correlation was evidenced for keratometry values between platforms (r = 0.903, P = 0.0001 for K1, and r = 0.890, P = 0.0001). Bland-Altman plots showed a wide data spread for all variables. The image-guided system provided highly repeatable corneal power and keratometry measurements. However, significant differences were evidenced between the two platforms, and although values were highly correlated, they showed a wide data spread for all analysed variables; therefore, their interchangeable use for biometry assessment is not advisable.
Rubin, I; Lykkegaard, S; Olsen, A A; Selmer, J; Ballegaard, M
1988-01-01
Monoclonal antibodies were produced against human angiotensinogen. An enzyme linked immunosorbent assay (ELISA) was developed using a high affinity monoclonal antibody as catching antibody and a polyclonal rabbit anti human angiotensinogen antibody as detecting antibody in a "sandwich" ELISA. Linear range of the ELISA was 15-450 pmol/l of human angiotensinogen. Intra- and inter- assay variation coefficients were in the range of 2% to 8%. A correlation coefficient, r = 0.97, (n = 20), with values obtained by radioimmunoassay. This correlation coefficient, obtained by using both normal and pregnant sera, confirmed that the ELISA fulfill the requirements for clinical useful assay. Characterization of the antibodies were performed with respect to affinity constant and epitopes.
Zhang, Z L; Li, J P; Li, G; Ma, X C
2017-02-09
Objective: To establish and validate a computer program used to aid the detection of dental proximal caries in the images cone beam computed tomography (CBCT) images. Methods: According to the characteristics of caries lesions in X-ray images, a computer aided detection program for proximal caries was established with Matlab and Visual C++. The whole process for caries lesion detection included image import and preprocessing, measuring average gray value of air area, choosing region of interest and calculating gray value, defining the caries areas. The program was used to examine 90 proximal surfaces from 45 extracted human teeth collected from Peking University School and Hospital of Stomatology. The teeth were then scanned with a CBCT scanner (Promax 3D). The proximal surfaces of the teeth were respectively detected by caries detection program and scored by human observer for the extent of lesions with 6-level-scale. With histologic examination serving as the reference standard, the caries detection program and the human observer performances were assessed with receiver operating characteristic (ROC) curves. Student t -test was used to analyze the areas under the ROC curves (AUC) for the differences between caries detection program and human observer. Spearman correlation coefficient was used to analyze the detection accuracy of caries depth. Results: For the diagnosis of proximal caries in CBCT images, the AUC values of human observers and caries detection program were 0.632 and 0.703, respectively. There was a statistically significant difference between the AUC values ( P= 0.023). The correlation between program performance and gold standard (correlation coefficient r (s)=0.525) was higher than that of observer performance and gold standard ( r (s)=0.457) and there was a statistically significant difference between the correlation coefficients ( P= 0.000). Conclusions: The program that automatically detects dental proximal caries lesions could improve the diagnostic value of CBCT images.
Fully automated, deep learning segmentation of oxygen-induced retinopathy images
Xiao, Sa; Bucher, Felicitas; Wu, Yue; Rokem, Ariel; Lee, Cecilia S.; Marra, Kyle V.; Fallon, Regis; Diaz-Aguilar, Sophia; Aguilar, Edith; Friedlander, Martin; Lee, Aaron Y.
2017-01-01
Oxygen-induced retinopathy (OIR) is a widely used model to study ischemia-driven neovascularization (NV) in the retina and to serve in proof-of-concept studies in evaluating antiangiogenic drugs for ocular, as well as nonocular, diseases. The primary parameters that are analyzed in this mouse model include the percentage of retina with vaso-obliteration (VO) and NV areas. However, quantification of these two key variables comes with a great challenge due to the requirement of human experts to read the images. Human readers are costly, time-consuming, and subject to bias. Using recent advances in machine learning and computer vision, we trained deep learning neural networks using over a thousand segmentations to fully automate segmentation in OIR images. While determining the percentage area of VO, our algorithm achieved a similar range of correlation coefficients to that of expert inter-human correlation coefficients. In addition, our algorithm achieved a higher range of correlation coefficients compared with inter-expert correlation coefficients for quantification of the percentage area of neovascular tufts. In summary, we have created an open-source, fully automated pipeline for the quantification of key values of OIR images using deep learning neural networks. PMID:29263301
Steinborn, M; Fiegler, J; Kraus, V; Denne, C; Hapfelmeier, A; Wurzinger, L; Hahn, H
2011-12-01
We performed a cadaver study to evaluate the accuracy of measurements of the optic nerve and the optic nerve sheath for high resolution US (HRUS) and magnetic resonance imaging (MRI). Five Thiel-fixated cadaver specimens of the optic nerve were examined with HRUS and MRI. Measurements of the optic nerve and the ONSD were performed before and after the filling of the optic nerve sheath with saline solution. Statistical analysis included the calculation of the agreement of measurements and the evaluation of the intraobserver and interobserver variation. Overall a good correlation of measurement values between HRUS and MRI can be found (mean difference: 0.02-0.97 mm). The repeatability coefficient (RC) and concordance correlation coefficient (CCC) values were good to excellent for most acquisitions (RC 0.2-1.11 mm; CCC 0.684-0.949). The highest variation of measurement values was found for transbulbar sonography (RC 0.58-1.83 mm; CCC 0.615/0.608). If decisive anatomic structures are clearly depicted and the measuring points are set correctly, there is a good correlation between HRUS and MRI measurements of the optic nerve and the ONSD even on transbulbar sonography. As most of the standard and cut-off values that have been published for ultrasound are significantly lower than the results obtained with MRI, a reevaluation of sonographic ONSD measurement with correlation to MRI is necessary. © Georg Thieme Verlag KG Stuttgart · New York.
Yamashiro, Tsuneo; Moriya, Hiroshi; Tsubakimoto, Maho; Matsuoka, Shin; Murayama, Sadayuki
2016-01-01
Purpose Four-dimensional dynamic-ventilation computed tomography (CT) imaging demonstrates continuous movement of the airways and lungs, which cannot be depicted with conventional CT. We aimed to investigate continuous changes in lung density and airway dimensions and to assess the correlation with spirometric values in smokers. Materials and methods This retrospective study was approved by the Institutional Review Board, and informed consent was waived. Twenty-one smokers including six patients with COPD underwent four-dimensional dynamic-ventilation CT during free breathing (160 mm in length). The mean lung density (MLD) of the scanned lung and luminal areas (Ai) of fixed points in the trachea and the right proximal bronchi (main bronchus, upper bronchus, bronchus intermedius, and lower bronchus) were continuously measured. Concordance between the time curve of the MLD and that of the airway Ai values was expressed by cross-correlation coefficients. The associations between these quantitative measurements and the forced expiratory volume in 1 second/forced vital capacity (FEV1/FVC) values were assessed by Spearman’s rank correlation analysis. Results On the time curve for the MLD, the Δ-MLD1.05 values between the peak inspiratory frame to the later third frame (1.05 seconds later) were strongly correlated with the FEV1/FVC (ρ=0.76, P<0.0001). The cross-correlation coefficients between the airway Ai and MLD values were significantly correlated with the FEV1/FVC (ρ=−0.56 to −0.66, P<0.01), except for the right upper bronchus. This suggested that the synchrony between the airway and lung movement was lost in patients with severe airflow limitation. Conclusion Respiratory changes in the MLD and synchrony between the airway Ai and the MLD measured with dynamic-ventilation CT were correlated with patient’s spirometric values. PMID:27110108
Comparison of Nimbus-7 SMMR and GOES-1 VISSR Atmospheric Liquid Water Content.
NASA Astrophysics Data System (ADS)
Lojou, Jean-Yves; Frouin, Robert; Bernard, René
1991-02-01
Vertically integrated atmospheric liquid water content derived from Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) brightness temperatures and from GOES-1 Visible and Infrared Spin-Scan Radiometer (VISSR) radiances in the visible are compared over the Indian Ocean during MONEX (monsoon experiment). In the retrieval procedure, Wilheit and Chang' algorithm and Stephens' parameterization schemes are applied to the SMMR and VISSR data, respectively. The results indicate that in the 0-100 mg cm2 range of liquid water content considered, the correlation coefficient between the two types of estimates is 0.83 (0.81- 0.85 at the 99 percent confidence level). The Wilheit and Chang algorithm, however, yields values lower than those obtained with Stephens's schemes by 24.5 mg cm2 on the average, and occasionally the SMMR-based values are negative. Alternative algorithms are proposed for use with SMMR data, which eliminate the bias, augment the correlation coefficient, and reduce the rms difference. These algorithms include using the Witheit and Chang formula with modified coefficients (multilinear regression), the Wilheit and Chang formula with the same coefficients but different equivalent atmospheric temperatures for each channel (temperature bias adjustment), and a second-order polynomial in brightness temperatures at 18, 21, and 37 GHz (polynomial development). When applied to a dataset excluded from the regressionn dataset, the multilinear regression algorithm provides the best results, namely a 0.91 correlation coefficient, a 5.2 mg cm2 (residual) difference, and a 2.9 mg cm2 bias. Simply shifting the liquid water content predicted by the Wilheit and Chang algorithm does not yield as good comparison statistics, indicating that the occasional negative values are not due only to a bias. The more accurate SMMR-derived liquid water content allows one to better evaluate cloud transmittance in the solar spectrum, at least in the area and during the period analyzed. Combining this cloud transmittance with a clear sky model would provide ocean surface insulation estimates from SMMR data alone.
Pasha, Sharif M; Klok, Frederikus A; van der Bijl, Noortje; de Roos, Albert; Kroft, Lucia J M; Huisman, Menno V
2012-08-01
N-terminal pro-Brain Natriuretic Peptide (NT-pro-BNP) is primarily secreted by left ventricular (LV) stretch and wall tension. Notably, NT-pro-BNP is a prognostic marker in acute pulmonary embolism (PE), which primarily stresses the right ventricle (RV). We sought to evaluate the relative contribution of the RV to NT-pro-BNP levels during PE. A post-hoc analysis of an observational prospective outcome study in 113 consecutive patients with computed tomography (CT)-proven PE and 226 patients in whom PE was clinically suspected but ruled out by CT. In all patients RV and LV function was established by assessing ECG-triggered-CT measured ventricular end-diastolic-volumes and ejection fraction (EF). NT-pro-BNP was assessed in all patients. The correlation between RV and LV end-diastolic-volumes and systolic function was evaluated by multiple linear regression corrected for known confounders. In the PE cohort increased RVEF (β-coefficient (95% confidence interval [CI]) -0.044 (± -0.011); p<0.001) and higher RV end-diastolic-volume (β-coefficient 0.005 (± 0.001); p<0.001) were significantly correlated to NT-pro-BNP, while no correlation was found with LVEF (β-coefficient 0.005 (± 0.010); p=0.587) and LV end-diastolic-volume (β-coefficient -0.003 (± 0.002); p=0.074). In control patients without PE we found a strong correlation between NT-pro-BNP levels and LVEF (β-coefficient -0.027 (± -0.006); p<0.001) although not LV end-diastolic-volume (β-coefficient 0.001 (± 0.001); p=0.418). RVEF (β-coefficient -0.002 (± -0.006); p=0.802) and RV end-diastolic-volume (β-coefficient <0.001 (± 0.001); p=0.730) were not correlated in patients without PE. In PE patients, lower RVEF and higher RV end-diastolic-volume were significantly correlated to NT-pro-BNP levels as compared to control patients without PE. These observations provide pathophysiological ground for the well-known prognostic value of NT-pro-BNP in acute PE.
Detection of Unexpected High Correlations between Balance Calibration Loads and Load Residuals
NASA Technical Reports Server (NTRS)
Ulbrich, N.; Volden, T.
2014-01-01
An algorithm was developed for the assessment of strain-gage balance calibration data that makes it possible to systematically investigate potential sources of unexpected high correlations between calibration load residuals and applied calibration loads. The algorithm investigates correlations on a load series by load series basis. The linear correlation coefficient is used to quantify the correlations. It is computed for all possible pairs of calibration load residuals and applied calibration loads that can be constructed for the given balance calibration data set. An unexpected high correlation between a load residual and a load is detected if three conditions are met: (i) the absolute value of the correlation coefficient of a residual/load pair exceeds 0.95; (ii) the maximum of the absolute values of the residuals of a load series exceeds 0.25 % of the load capacity; (iii) the load component of the load series is intentionally applied. Data from a baseline calibration of a six-component force balance is used to illustrate the application of the detection algorithm to a real-world data set. This analysis also showed that the detection algorithm can identify load alignment errors as long as repeat load series are contained in the balance calibration data set that do not suffer from load alignment problems.
Ikomey, G; Assoumou, M-C Okomo; Atashili, J; Mesembe, M; Mukwele, B; Lyonga, E; Eyoh, A; Kafando, A; Ndumbe, P M
2016-09-01
Difficulties in systematically monitoring HIV viral load in resource-limited settings prompt the search for alternate approaches. The authors aimed at assessing the correlation between the plasma levels of soluble forms of Fas receptors (Fas) and Fas ligands (FasL) with standard indicators of HIV disease progression in children. Twenty-two HIV-1-positive children were enrolled in Yaounde. CD4 counts, CD4% counts, plasma levels of Fas, FasL, and HIV-1 RNA levels were assayed. The correlation coefficients (P values) between FasL levels and each of HIV-1 viral load, CD4 counts, and CD4% were, respectively, .56 (.01), -.29 (.18), and .30 (.18). On the other hand, the respective correlation coefficients (P values) with Fas levels were .12 (.60), -.30 (.18), and -.29 (.19). The significant correlation between levels of HIV-1 viral load and FasL suggests that the latter needs to be further studied as a potential biomarker to monitor HIV-1 disease progression in children in resource-limited setting. © The Author(s) 2013.
Statistical procedures for evaluating daily and monthly hydrologic model predictions
Coffey, M.E.; Workman, S.R.; Taraba, J.L.; Fogle, A.W.
2004-01-01
The overall study objective was to evaluate the applicability of different qualitative and quantitative methods for comparing daily and monthly SWAT computer model hydrologic streamflow predictions to observed data, and to recommend statistical methods for use in future model evaluations. Statistical methods were tested using daily streamflows and monthly equivalent runoff depths. The statistical techniques included linear regression, Nash-Sutcliffe efficiency, nonparametric tests, t-test, objective functions, autocorrelation, and cross-correlation. None of the methods specifically applied to the non-normal distribution and dependence between data points for the daily predicted and observed data. Of the tested methods, median objective functions, sign test, autocorrelation, and cross-correlation were most applicable for the daily data. The robust coefficient of determination (CD*) and robust modeling efficiency (EF*) objective functions were the preferred methods for daily model results due to the ease of comparing these values with a fixed ideal reference value of one. Predicted and observed monthly totals were more normally distributed, and there was less dependence between individual monthly totals than was observed for the corresponding predicted and observed daily values. More statistical methods were available for comparing SWAT model-predicted and observed monthly totals. The 1995 monthly SWAT model predictions and observed data had a regression Rr2 of 0.70, a Nash-Sutcliffe efficiency of 0.41, and the t-test failed to reject the equal data means hypothesis. The Nash-Sutcliffe coefficient and the R r2 coefficient were the preferred methods for monthly results due to the ability to compare these coefficients to a set ideal value of one.
Revisiting crash spatial heterogeneity: A Bayesian spatially varying coefficients approach.
Xu, Pengpeng; Huang, Helai; Dong, Ni; Wong, S C
2017-01-01
This study was performed to investigate the spatially varying relationships between crash frequency and related risk factors. A Bayesian spatially varying coefficients model was elaborately introduced as a methodological alternative to simultaneously account for the unstructured and spatially structured heterogeneity of the regression coefficients in predicting crash frequencies. The proposed method was appealing in that the parameters were modeled via a conditional autoregressive prior distribution, which involved a single set of random effects and a spatial correlation parameter with extreme values corresponding to pure unstructured or pure spatially correlated random effects. A case study using a three-year crash dataset from the Hillsborough County, Florida, was conducted to illustrate the proposed model. Empirical analysis confirmed the presence of both unstructured and spatially correlated variations in the effects of contributory factors on severe crash occurrences. The findings also suggested that ignoring spatially structured heterogeneity may result in biased parameter estimates and incorrect inferences, while assuming the regression coefficients to be spatially clustered only is probably subject to the issue of over-smoothness. Copyright © 2016 Elsevier Ltd. All rights reserved.
Semimajor Axis Estimation Strategies
NASA Technical Reports Server (NTRS)
How, Jonathan P.; Alfriend, Kyle T.; Breger, Louis; Mitchell, Megan
2004-01-01
This paper extends previous analysis on the impact of sensing noise for the navigation and control aspects of formation flying spacecraft. We analyze the use of Carrier-phase Differential GPS (CDGPS) in relative navigation filters, with a particular focus on the filter correlation coefficient. This work was motivated by previous publications which suggested that a "good" navigation filter would have a strong correlation (i.e., coefficient near -1) to reduce the semimajor axis (SMA) error, and therefore, the overall fuel use. However, practical experience with CDGPS-based filters has shown this strong correlation seldom occurs (typical correlations approx. -0.1), even when the estimation accuracies are very good. We derive an analytic estimate of the filter correlation coefficient and demonstrate that, for the process and sensor noises levels expected with CDGPS, the expected value will be very low. It is also demonstrated that this correlation can be improved by increasing the time step of the discrete Kalman filter, but since the balance condition is not satisfied, the SMA error also increases. These observations are verified with several linear simulations. The combination of these simulations and analysis provide new insights on the crucial role of the process noise in determining the semimajor axis knowledge.
Ramírez-Vélez, Robinson; Tordecilla-Sanders, Alejandra; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; González-Jiménez, Emilio; Triana-Reina, Hector Reynaldo; García-Hermoso, Antonio; Schmidt-RioValle, Jacqueline
2018-01-01
To verify the validity of multi-frequency bioelectrical impedance analysis (mBCA) for predicting body fat percentage (BF%) in overweight/obese adults using dual-energy X-ray absorptiometry (DXA) as the reference method. Forty-eight adults participated (54% women, mean age = 41.0 ± 7.3 years old). The Pearson's correlation coefficient was used to evaluate the correlation between BIA and BF% assessed by DXA. The concordance between BF% measured by both methods was obtained with Lin's concordance correlation coefficient and Bland-Altman difference plots. Measures of BF% were estimated as 39.0 (SD = 6.1) and 38.3 (SD = 6.5) using DXA and mBCA, respectively. The Pearson's correlation coefficient reflected a strong correlation (r =.921, P = .001). The paired t-test showed a significant mean difference between these methods for obese men BF% of -0.6 [(SD 1.95; 95% CI = -4.0 to 3.0), P =.037]. Overall, the bias of the mBCA was -0.6 [(SD 2.2; 95% CI = -5.0 to 3.7), P =.041], which indicated that the mBCA method significantly underestimated BF% in comparison to the reference method. Finally, in both genders, Lin's concordance correlation coefficient showed a strong agreement. More specifically the DXA value was ρc = 0.943 (95% CI = 0.775 to 0.950) and the mBCA value was ρc = 0.948 (95% CI = 0.778 to 0.978). Our analysis showed a strong agreement between the two methods as reflected in the range of BF%. These results show that mBCA and DXA are comparable methods for measuring body composition with higher body fat percentages. However, due to broad limits of agreement, we can only recommend mBCA for groups of populations. © 2017 Wiley Periodicals, Inc.
[Nitrogen status diagnosis of rice by using a digital camera].
Jia, Liang-Liang; Fan, Ming-Sheng; Zhang, Fu-Suo; Chen, Xin-Ping; Lü, Shi-Hua; Sun, Yan-Ming
2009-08-01
In the present research, a field experiment with different N application rate was conducted to study the possibility of using visible band color analysis methods to monitor the N status of rice canopy. The Correlations of visible spectrum band color intensity between rice canopy image acquired from a digital camera and conventional nitrogen status diagnosis parameters of leaf SPAD chlorophyll meter readings, total N content, upland biomass and N uptake were studied. The results showed that the red color intensity (R), green color intensity (G) and normalized redness intensity (NRI) have significant inverse linear correlations with the conventional N diagnosis parameters of SPAD readings, total N content, upland biomass and total N uptake. The correlation coefficient values (r) were from -0.561 to -0.714 for red band (R), from -0.452 to -0.505 for green band (G), and from -0.541 to 0.817 for normalized redness intensity (NRI). But the normalized greenness intensity (NGI) showed a significant positive correlation with conventional N parameters and the correlation coefficient values (r) were from 0.505 to 0.559. Compared with SPAD readings, the normalized redness intensity (NRI), with a high r value of 0.541-0.780 with conventional N parameters, could better express the N status of rice. The digital image color analysis method showed the potential of being used in rice N status diagnosis in the future.
Shih, I-Lun; Yen, Ruoh-Fang; Chen, Chi-An; Chen, Bang-Bin; Wei, Shwu-Yuan; Chang, Wen-Chun; Sheu, Bor-Ching; Cheng, Wen-Fang; Tseng, Yao-Hui; Chen, Xin-Jia; Chen, Chi-Hau; Wei, Lin-Hung; Chiang, Ying-Cheng; Torng, Pao-Ling; Yen, Men-Luh; Shih, Tiffany Ting-Fang
2015-12-01
To evaluate the correlation between maximum standardized uptake value (SUVmax ) and minimum apparent diffusion coefficient (ADCmin ) of endometrial cancer derived from an integrated positron emission tomography / magnetic resonance (PET/MR) system and to determine their correlation with pathological prognostic factors. This prospective study was approved by the Institutional Review Board of the hospital, and informed consent was obtained. Between April and December 2014, 47 consecutive patients with endometrial cancer were enrolled and underwent simultaneous PET/MR examinations before surgery. Thirty-six patients with measurable tumors on PET/MR were included for image analysis. Pearson's correlation coefficient was used to evaluate the correlation between SUVmax and ADCmin of the tumors. The Mann-Whitney U-test was utilized to evaluate relationships between these two imaging biomarkers and pathological prognostic factors. The mean SUVmax and ADCmin were 14.7 ± 7.1 and 0.48 ± 0.13 × 10(-3) mm(2) /s, respectively. A significant inverse correlation was found between SUVmax and ADCmin (r = -0.53; P = 0.001). SUVmax was significantly higher in tumors with advanced stage, deep myometrial invasion, cervical invasion, lymphovascular space involvement, and lymph node metastasis (P < 0.05). ADCmin was lower in tumors with higher grade, advanced stage, and cervical invasion (P < 0.05). The ratio of SUVmax to ADCmin was higher in tumors with higher grade, advanced stage, deep myometrial invasion, cervical invasion, lymphovascular space involvement, and lymph node metastasis (P < 0.05). SUVmax and ADCmin of endometrial cancer derived from integrated PET/MR are inversely correlated and are associated with pathological prognostic factors. © 2015 Wiley Periodicals, Inc.
NAGANAWA, Shinji; KANOU, Mai; OHASHI, Toshio; KUNO, Kayao; SONE, Michihiko
2016-01-01
Purpose: To evaluate the feasibility of a simple estimation for the endolymphatic volume ratio (endolymph volume/total lymph volume = %ELvolume) from an area ratio obtained from only one slice (%EL1slice) or from three slices (%EL3slices). The %ELvolume, calculated from a time-consuming measurement on all magnetic resonance (MR) slices, was compared to the %EL1slice and the %EL3slices. Methods: In 40 ears of 20 patients with a clinical suspicion of endolymphatic hydrops, MR imaging was performed 4 hours after intravenous administration of a single dose of gadolinium-based contrast material (IV-SD-GBCM). Using previously reported HYDROPS2-Mi2 MR imaging, the %ELvolume values in the cochlea and the vestibule were measured separately by two observers. The correlations between the %EL1slice or the %EL3slices and the %ELvolume values were evaluated. Results: A strong linear correlation was observed between the %ELvolume and the %EL3slices or the %EL1slice in the cochlea. The Pearson correlation coefficient (r) was 0.968 (3 slices) and 0.965 (1 slice) for observer A, and 0.968 (3 slices) and 0.964 (1 slice) for observer B (P < 0.001, for all). A strong linear correlation was also observed between the %ELvolume and the %EL3slices or the %EL1slice in the vestibule. The Pearson correlation coefficient (r) was 0.980 (3 slices) and 0.953 (1 slice) for observer A, and 0.979 (3 slices) and 0.952 (1 slice) for observer B (P < 0.001, for all). The high intra-class correlation coefficients (0.991–0.997) between the endolymph volume ratios by two observers were observed in both the cochlea and the vestibule for values of the %ELvolume, the %EL3slices and the %EL1slice. Conclusion: The %ELvolume might be easily estimated from the %EL3slices or the %EL1slice. PMID:27001396
Naganawa, Shinji; Kanou, Mai; Ohashi, Toshio; Kuno, Kayao; Sone, Michihiko
2016-10-11
To evaluate the feasibility of a simple estimation for the endolymphatic volume ratio (endolymph volume/total lymph volume = %EL volume ) from an area ratio obtained from only one slice (%EL 1slice ) or from three slices (%EL 3slices ). The %EL volume, calculated from a time-consuming measurement on all magnetic resonance (MR) slices, was compared to the %EL 1slice and the %EL 3slices . In 40 ears of 20 patients with a clinical suspicion of endolymphatic hydrops, MR imaging was performed 4 hours after intravenous administration of a single dose of gadolinium-based contrast material (IV-SD-GBCM). Using previously reported HYDROPS2-Mi2 MR imaging, the %EL volume values in the cochlea and the vestibule were measured separately by two observers. The correlations between the %EL 1slice or the %EL 3slices and the %EL volume values were evaluated. A strong linear correlation was observed between the %EL volume and the %EL 3slices or the %EL 1slice in the cochlea. The Pearson correlation coefficient (r) was 0.968 (3 slices) and 0.965 (1 slice) for observer A, and 0.968 (3 slices) and 0.964 (1 slice) for observer B (P < 0.001, for all). A strong linear correlation was also observed between the %EL volume and the %EL 3slices or the %EL 1slice in the vestibule. The Pearson correlation coefficient (r) was 0.980 (3 slices) and 0.953 (1 slice) for observer A, and 0.979 (3 slices) and 0.952 (1 slice) for observer B (P < 0.001, for all). The high intra-class correlation coefficients (0.991-0.997) between the endolymph volume ratios by two observers were observed in both the cochlea and the vestibule for values of the %EL volume , the %EL 3slices and the %EL 1slice . The %EL volume might be easily estimated from the %EL 3slices or the %EL 1slice .
Sorption of the monoterpenes α-pinene and limonene to carbonaceous geosorbents including biochar.
Hale, Sarah E; Endo, Satoshi; Arp, Hans Peter H; Zimmerman, Andrew R; Cornelissen, Gerard
2015-01-01
The sorption of two monoterpenes, α pinene and limonene to the carbonaceous geosorbents graphite, bituminous coal, lignite coke, biochar and Pahokee peat was quantified. Polyethylene (PE) passive samplers were calibrated for the first time for these compounds by determining the PE-water partitioning coefficients and used as a tool to determine sorption to the carbonaceous geosorbents. Log KPE-water values were 3.49±0.58 for α pinene and 4.08±0.27 for limonene. The sorption of limonene to all materials was stronger than that for α pinene (differences of 0.2-1.3 log units between distribution coefficients for the monoterpenes). Placing Kd values in increasing order for α pinene gave biochar≈Pahokee peat≈bituminous coal≈lignite coke
Vosoughi, Amir Reza; Roustaei, Narges; Mahdaviazad, Hamideh
2018-06-01
The use of valid and reliable outcome rating scales is essential for evaluating the result of different treatments and interventions. The purposes of this study were to translate and culturally adapt the American Orthopaedic Foot and Ankle Society ankle-hindfoot scale (AOFAS-AHFS) into Persian languages and evaluate its psychometric properties. Forward-backward translation and cultural adaptation method were used to develop Persian version of AOFAS-AHFS. From March to July 2016, one hundred consecutive patients with ankle and hindfoot injuries were included. Internal consistency and reproducibility were evaluated using Cronbach's alpha, Spearman's rank correlation coefficient and Intraclass correlation coefficient (ICC) respectively. Construct validity reported which compare the outcome rating scale measurements with Short Form-36 (SF-36), also convergent and discriminant validity evaluated using Spearman's rank correlation coefficient. Mean age (SD) of the patients was 41.95±13.45years. Cronbach's α coefficient, Spearman's rho and ICC values were 0.71, 0.89 and 0.90 respectively. Total score of AOFAS-AHFS and SF-36 domains has a correlation ranged between 0.17-0.55. Spearman's rank correlation coefficient of 0.4 was exceeded by all items with the exception of stability. The Spearman's rank correlation between each item in functional subscales with its own subscales was higher than the correlation between these items and other subscales. Persian version of AOFAS-AHFS provides additional reliable and valid instrument which can be used to assess broad range of patients with foot and ankle disorders that speaking in Persian. However, it seems that the original version of AOFAS-AHFS needs some revisions. Copyright © 2017 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.
Development of a rapid, simple assay of plasma total carotenoids
2012-01-01
Background Plasma total carotenoids can be used as an indicator of risk of chronic disease. Laboratory analysis of individual carotenoids by high performance liquid chromatography (HPLC) is time consuming, expensive, and not amenable to use beyond a research laboratory. The aim of this research is to establish a rapid, simple, and inexpensive spectrophotometric assay of plasma total carotenoids that has a very strong correlation with HPLC carotenoid profile analysis. Results Plasma total carotenoids from 29 volunteers ranged in concentration from 1.2 to 7.4 μM, as analyzed by HPLC. A linear correlation was found between the absorbance at 448 nm of an alcohol / heptane extract of the plasma and plasma total carotenoids analyzed by HPLC, with a Pearson correlation coefficient of 0.989. The average coefficient of variation for the spectrophotometric assay was 6.5% for the plasma samples. The limit of detection was about 0.3 μM and was linear up to about 34 μM without dilution. Correlations between the integrals of the absorption spectra in the range of carotenoid absorption and total plasma carotenoid concentration gave similar results to the absorbance correlation. Spectrophotometric assay results also agreed with the calculated expected absorbance based on published extinction coefficients for the individual carotenoids, with a Pearson correlation coefficient of 0.988. Conclusion The spectrophotometric assay of total carotenoids strongly correlated with HPLC analysis of carotenoids of the same plasma samples and expected absorbance values based on extinction coefficients. This rapid, simple, inexpensive assay, when coupled with the carotenoid health index, may be useful for nutrition intervention studies, population cohort studies, and public health interventions. PMID:23006902
NASA Astrophysics Data System (ADS)
Ahmed, Syed Muzamil; Kazi, S. N.; Khan, Ghulamullah; Sadri, Rad; Dahari, Mahidzal; Zubir, M. N. M.; Sayuti, M.; Ahmad, Pervaiz; Ibrahim, Rushdan
2018-03-01
Heat transfer coefficients were obtained for a range of non-wood kenaf bast pulp fiber suspensions flowing through a circular pipe heat exchanger test loop. The data were produced over a selected temperature and range of flow rates from the flow loop. It was found that the magnitude of the heat transfer coefficient of a fiber suspension is dependent on characteristics, concentration and pulping method of fiber. It was observed that at low concentration and high flow rates, the heat transfer coefficient values of suspensions were observed higher than that of the heat transfer coefficient values of water, on the other hand the heat transfer coefficient values of suspensions decreases at low flow rates and with the increase of their concentration. The heat transfer were affected by varying fiber characteristics, such as fiber length, fiber flexibility, fiber chemical and mechanical treatment as well as different pulping methods used to liberate the fibers. Heat transfer coefficient was decreased with the increase of fiber flexibility which was also observed by previous researchers. In the present work, the characteristics of fibers are correlated with the heat transfer coefficient of suspensions of the fibers. Deviations in fiber properties can be monitored from the flowing fiber suspensions by measuring heat transfer coefficient to adjust the degree of fiber refining treatment so that papers made from those fibers will be more uniform, consistent, within the product specification and retard the paper production loss.
Heat Transfer at a Long Electrically-Simulated Water Wall in a Circulating Fluidised Bed
NASA Astrophysics Data System (ADS)
Sundaresan, R.; Kolar, Ajit Kumar
In the present work, heat transfer measurements are reported in a 100mm square, 5.5 m tall, cold CFB. The test section is a 19 mm OD electrically heated heat transfer tube, 4.64 m tall (covering more than 80% of the CFB height), sandwiched between two equally tall dummy tubes of 19mm OD, thus simulating a water wall geometry, forming one wall of the CFB. Narrow cut sand particles of mean diameters 156, 256, and 362 micrometers, and a wide cut sample of mean diameter 265 micrometer were used as the bed material. The superficial gas velocity ranged from 4.2 to 8.2 m/s, and the solids recycle flux varied from 17 to 110 kg/m2s. Local heat transfer coefficient at the simulated water wall varies, as expected from a low value at the top of the riser to a high value at the bottom, with an interesting increasing and decreasing trend in between. The average heat transfer coefficients were compared with those available in open literature. Correlations for average heat transfer coefficient are presented, both in terms of an average suspension density and also in terms of important nondimensional numbers, namely, Froude number, relative solids flux and velocity ratio. Comparisons are also made with predictions of relevant heat transfer models. Based on the present fifty-five experimental data points, the following correlation was presented with a correlation coefficient of 0.862 and maximum error is ± 15 %.
NASA Astrophysics Data System (ADS)
Atuegwu, N. C.; Colvin, D. C.; Loveless, M. E.; Xu, L.; Gore, J. C.; Yankeelov, T. E.
2012-01-01
We build on previous work to show how serial diffusion-weighted MRI (DW-MRI) data can be used to estimate proliferation rates in a rat model of brain cancer. Thirteen rats were inoculated intracranially with 9L tumor cells; eight rats were treated with the chemotherapeutic drug 1,3-bis(2-chloroethyl)-1-nitrosourea and five rats were untreated controls. All animals underwent DW-MRI immediately before, one day and three days after treatment. Values of the apparent diffusion coefficient (ADC) were calculated from the DW-MRI data and then used to estimate the number of cells in each voxel and also for whole tumor regions of interest. The data from the first two imaging time points were then used to estimate the proliferation rate of each tumor. The proliferation rates were used to predict the number of tumor cells at day three, and this was correlated with the corresponding experimental data. The voxel-by-voxel analysis yielded Pearson's correlation coefficients ranging from -0.06 to 0.65, whereas the region of interest analysis provided Pearson's and concordance correlation coefficients of 0.88 and 0.80, respectively. Additionally, the ratio of positive to negative proliferation values was used to separate the treated and control animals (p <0.05) at an earlier point than the mean ADC values. These results further illustrate how quantitative measurements of tumor state obtained non-invasively by imaging can be incorporated into mathematical models that predict tumor growth.
NASA Astrophysics Data System (ADS)
Jain, Neha; Shukla, Prashant; Singh, Jai
2018-05-01
Correlation images are very useful in determining the morphological changes. We have investigated the correlation image analysis on depolarization and retardance matrices of polystyrene and gelatine samples respectively. We observed that that correlation images have a potential to show a significant variation with change in the concentration of samples (polystyrene and gelatine). For polystyrene microspheres the correlation value decreases with increasing scattering coefficient. In gelatine samples the correlation also decreases with sample concentration. This variation in correlation for retardance shows the change in a birefringence property of gelatine solution.
Chiou, C.T.
1985-01-01
Triolein-water partition coefficients (KtW) have been determined for 38 slightly water-soluble organic compounds, and their magnitudes have been compared with the corresponding octanol-water partition coefficients (KOW). In the absence of major solvent-solute interaction effects in the organic solvent phase, the conventional treatment (based on Raoult's law) predicts sharply lower partition coefficients for most of the solutes in triolein because of its considerably higher molecular weight, whereas the Flory-Huggins treatment predicts higher partition coefficients with triolein. The data are in much better agreement with the Flory-Huggins model. As expected from the similarity in the partition coefficients, the water solubility (which was previously found to be the major determinant of the KOW) is also the major determinant for the Ktw. When the published BCF values (bioconcentration factors) of organic compounds in fish are based on the lipid content rather than on total mass, they are approximately equal to the Ktw, which suggests at least near equilibrium for solute partitioning between water and fish lipid. The close correlation between Ktw and Kow suggests that Kow is also a good predictor for lipid-water partition coefficients and bioconcentration factors.
De Geer, Jakob; Sandstedt, Mårten; Björkholm, Anders; Alfredsson, Joakim; Janzon, Magnus; Engvall, Jan; Persson, Anders
2016-10-01
The significance of a coronary stenosis can be determined by measuring the fractional flow reserve (FFR) during invasive coronary angiography. Recently, methods have been developed which claim to be able to estimate FFR using image data from standard coronary computed tomography angiography (CCTA) exams. To evaluate the accuracy of non-invasively computed fractional flow reserve (cFFR) from CCTA. A total of 23 vessels in 21 patients who had undergone both CCTA and invasive angiography with FFR measurement were evaluated using a cFFR software prototype. The cFFR results were compared to the invasively obtained FFR values. Correlation was calculated using Spearman's rank correlation, and agreement using intraclass correlation coefficient (ICC). Sensitivity, specificity, accuracy, negative predictive value, and positive predictive value for significant stenosis (defined as both FFR ≤0.80 and FFR ≤0.75) were calculated. The mean cFFR value for the whole group was 0.81 and the corresponding mean invFFR value was 0.84. The cFFR sensitivity for significant stenosis (FFR ≤0.80/0.75) on a per-lesion basis was 0.83/0.80, specificity was 0.76/0.89, and accuracy 0.78/0.87. The positive predictive value was 0.56/0.67 and the negative predictive value was 0.93/0.94. The Spearman rank correlation coefficient was ρ = 0.77 (P < 0.001) and ICC = 0.73 (P < 0.001). This particular CCTA-based cFFR software prototype allows for a rapid, non-invasive on-site evaluation of cFFR. The results are encouraging and cFFR may in the future be of help in the triage to invasive coronary angiography. © The Foundation Acta Radiologica 2015.
Determination of the Avogadro constant by the XRCD method using a 28Si-enriched sphere
NASA Astrophysics Data System (ADS)
Kuramoto, Naoki; Mizushima, Shigeki; Zhang, Lulu; Fujita, Kazuaki; Azuma, Yasushi; Kurokawa, Akira; Okubo, Sho; Inaba, Hajime; Fujii, Kenichi
2017-10-01
To determine the Avogadro constant N A by the x-ray crystal density method, the density of a 28Si-enriched crystal was determined by absolute measurements of the mass and volume of a 1 kg sphere manufactured from the crystal. The mass and volume were determined by an optical interferometer and a vacuum mass comparator, respectively. The sphere surface was characterized by x-ray photoelectron spectroscopy and spectroscopic ellipsometry to derive the mass and volume of the Si core of the sphere excluding the surface layers. From the mass and volume, the density of the Si core was determined with a relative standard uncertainty of 2.3 × 10-8. By combining the Si core density with the lattice constant and the molar mass of the sphere reported by the International Avogadro Coordination (IAC) project in 2015, a new value of 6.022 140 84(15) × 1023 mol-1 was obtained for N A with a relative standard uncertainty of 2.4 × 10-8. To make the N A value determined in this work usable for a future adjustment of the fundamental constants by the CODATA Task Group on Fundamental Constants, the correlation of the new N A value with the N A values determined in our previous works was examined. The correlation coefficients with the values of N A determined by IAC in 2011 and 2015 were estimated to be 0.07 and 0.28, respectively. The correlation of the new N A value with the N A value determined by IAC in 2017 using a different 28Si-enriched crystal was also examined, and the correlation coefficient was estimated to be 0.21.
Zukotynski, Katherine A; Vajapeyam, Sridhar; Fahey, Frederic H; Kocak, Mehmet; Brown, Douglas; Ricci, Kelsey I; Onar-Thomas, Arzu; Fouladi, Maryam; Poussaint, Tina Young
2017-08-01
The purpose of this study was to describe baseline 18 F-FDG PET voxel characteristics in pediatric diffuse intrinsic pontine glioma (DIPG) and to correlate these metrics with baseline MRI apparent diffusion coefficient (ADC) histogram metrics, progression-free survival (PFS), and overall survival. Methods: Baseline brain 18 F-FDG PET and MRI scans were obtained in 33 children from Pediatric Brain Tumor Consortium clinical DIPG trials. 18 F-FDG PET images, postgadolinium MR images, and ADC MR images were registered to baseline fluid attenuation inversion recovery MR images. Three-dimensional regions of interest on fluid attenuation inversion recovery MR images and postgadolinium MR images and 18 F-FDG PET and MR ADC histograms were generated. Metrics evaluated included peak number, skewness, and kurtosis. Correlation between PET and MR ADC histogram metrics was evaluated. PET pixel values within the region of interest for each tumor were plotted against MR ADC values. The association of these imaging markers with survival was described. Results: PET histograms were almost always unimodal (94%, vs. 6% bimodal). None of the PET histogram parameters (skewness or kurtosis) had a significant association with PFS, although a higher PET postgadolinium skewness tended toward a less favorable PFS (hazard ratio, 3.48; 95% confidence interval [CI], 0.75-16.28 [ P = 0.11]). There was a significant association between higher MR ADC postgadolinium skewness and shorter PFS (hazard ratio, 2.56; 95% CI, 1.11-5.91 [ P = 0.028]), and there was the suggestion that this also led to shorter overall survival (hazard ratio, 2.18; 95% CI, 0.95-5.04 [ P = 0.067]). Higher MR ADC postgadolinium kurtosis tended toward shorter PFS (hazard ratio, 1.30; 95% CI, 0.98-1.74 [ P = 0.073]). PET and MR ADC pixel values were negatively correlated using the Pearson correlation coefficient. Further, the level of PET and MR ADC correlation was significantly positively associated with PFS; tumors with higher values of ADC-PET correlation had more favorable PFS (hazard ratio, 0.17; 95% CI, 0.03-0.89 [ P = 0.036]), suggesting that a higher level of negative ADC-PET correlation leads to less favorable PFS. A more significant negative correlation may indicate higher-grade elements within the tumor leading to poorer outcomes. Conclusion: 18 F-FDG PET and MR ADC histogram metrics in pediatric DIPG demonstrate different characteristics with often a negative correlation between PET and MR ADC pixel values. A higher negative correlation is associated with a worse PFS, which may indicate higher-grade elements within the tumor. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Rabasco, Paola; Caivano, Rocchina; Simeon, Vittorio; Dinardo, Giuseppina; Lotumolo, Antonella; Gioioso, Matilde; Villonio, Antonio; Iannelli, Giancarlo; D'Antuono, Felice; Zandolino, Alexis; Macarini, Luca; Guglielmi, Giuseppe; Cammarota, Aldo
2017-02-07
To analyze diffusion-weighted imaging (DWI) and the related apparent diffusion coefficient (ADC) in women with breast cancer, correlating these values with the presence at 3 years of distant metastases, and to demonstrate that DWI-Magnetic Resonance Imaging (MRI) and related ADC values may represent a prognostic value in the study of women with breast cancer. Sixty women (aged 45-73 years) affected with breast cancer with a follow-up in 3 years were enrolled. On DWI, we obtained the ADC values, and these were correlated with the clinical condition of patients at 3 years. Moreover, tumour size, lymph node status, and molecular markers, including estrogens receptor, progesterone receptor, Ki-67 index, and human growth factor receptor 2 protein, were correlated with ADC values. This study was approved by the Scientific Committee of our institution. We considered patients with metastasis at 3 years (12 patients - 20%) and without metastasis (48 patients - 80%). The mean ADC value in patients with no metastases at 3 years was 1.06 ± 0.38, while for patients with metastases it was 0.74 ± 0.34 (p = .011). The receiver-operator curve analysis identified a value of 0.75 (<0.75 with risk to develop metastasis) as the best predictive cutoff for ADC values, with the highest sensitivity (81.25%) and higher specificity (66.67%). After regression analysis, ADC value, positivity to estrogen-progestin receptors, and presence of lymph nodes were the only prognostic factors found to be statistically significant. DWI-MRI and related ADC values may represent a prognostic value in women with breast cancer.
Image analysis to evaluate the browning degree of banana (Musa spp.) peel.
Cho, Jeong-Seok; Lee, Hyeon-Jeong; Park, Jung-Hoon; Sung, Jun-Hyung; Choi, Ji-Young; Moon, Kwang-Deog
2016-03-01
Image analysis was applied to examine banana peel browning. The banana samples were divided into 3 treatment groups: no treatment and normal packaging (Cont); CO2 gas exchange packaging (CO); normal packaging with an ethylene generator (ET). We confirmed that the browning of banana peels developed more quickly in the CO group than the other groups based on sensory test and enzyme assay. The G (green) and CIE L(∗), a(∗), and b(∗) values obtained from the image analysis sharply increased or decreased in the CO group. And these colour values showed high correlation coefficients (>0.9) with the sensory test results. CIE L(∗)a(∗)b(∗) values using a colorimeter also showed high correlation coefficients but comparatively lower than those of image analysis. Based on this analysis, browning of the banana occurred more quickly for CO2 gas exchange packaging, and image analysis can be used to evaluate the browning of banana peels. Copyright © 2015 Elsevier Ltd. All rights reserved.
Short version of the Depression Anxiety Stress Scale-21: is it valid for Brazilian adolescents?
da Silva, Hítalo Andrade; dos Passos, Muana Hiandra Pereira; de Oliveira, Valéria Mayaly Alves; Palmeira, Aline Cabral; Pitangui, Ana Carolina Rodarti; de Araújo, Rodrigo Cappato
2016-01-01
ABSTRACT Objective To evaluate the interday reproducibility, agreement and validity of the construct of short version of the Depression Anxiety Stress Scale-21 applied to adolescents. Methods The sample consisted of adolescents of both sexes, aged between 10 and 19 years, who were recruited from schools and sports centers. The validity of the construct was performed by exploratory factor analysis, and reliability was calculated for each construct using the intraclass correlation coefficient, standard error of measurement and the minimum detectable change. Results The factor analysis combining the items corresponding to anxiety and stress in a single factor, and depression in a second factor, showed a better match of all 21 items, with higher factor loadings in their respective constructs. The reproducibility values for depression were intraclass correlation coefficient with 0.86, standard error of measurement with 0.80, and minimum detectable change with 2.22; and, for anxiety/stress: intraclass correlation coefficient with 0.82, standard error of measurement with 1.80, and minimum detectable change with 4.99. Conclusion The short version of the Depression Anxiety Stress Scale-21 showed excellent values of reliability, and strong internal consistency. The two-factor model with condensation of the constructs anxiety and stress in a single factor was the most acceptable for the adolescent population. PMID:28076595
Development of Cell Analysis Software for Cultivated Corneal Endothelial Cells.
Okumura, Naoki; Ishida, Naoya; Kakutani, Kazuya; Hongo, Akane; Hiwa, Satoru; Hiroyasu, Tomoyuki; Koizumi, Noriko
2017-11-01
To develop analysis software for cultured human corneal endothelial cells (HCECs). Software was designed to recognize cell borders and to provide parameters such as cell density, coefficient of variation, and polygonality of cultured HCECs based on phase contrast images. Cultured HCECs with high or low cell density were incubated with Ca-free and Mg-free phosphate-buffered saline for 10 minutes to reveal the cell borders and were then analyzed with software (n = 50). Phase contrast images showed that cell borders were not distinctly outlined, but these borders became more distinctly outlined after phosphate-buffered saline treatment and were recognized by cell analysis software. The cell density value provided by software was similar to that obtained using manual cell counting by an experienced researcher. Morphometric parameters, such as the coefficient of variation and polygonality, were also produced by software, and these values were significantly correlated with cell density (Pearson correlation coefficients -0.62 and 0.63, respectively). The software described here provides morphometric information from phase contrast images, and it enables subjective and noninvasive quality assessment for tissue engineering therapy of the corneal endothelium.
Anderson, Stephan W; Jara, Hernan; Ozonoff, Al; O'Brien, Michael; Hamilton, James A; Soto, Jorge A
2012-01-01
To evaluate the effects of hepatic fibrosis on ADC and T(2) values of ex vivo murine liver specimens imaged using 11.7 Tesla (T) MRI. This animal study was IACUC approved. Seventeen male, C57BL/6 mice were divided into control (n = 2) and experimental groups (n = 15), the latter fed a 3, 5-dicarbethoxy-1, 4-dihydrocollidine (DDC) supplemented diet, inducing hepatic fibrosis. Ex vivo liver specimens were imaged using an 11.7T MRI scanner. Spin-echo pulsed field gradient and multi-echo spin-echo acquisitions were used to generate parametric ADC and T(2) maps, respectively. Degrees of fibrosis were determined by the evaluation of a pathologist as well as digital image analysis. Scatterplot graphs comparing ADC and T(2) to degrees of fibrosis were generated and correlation coefficients were calculated. Strong correlation was found between degrees of hepatic fibrosis and ADC with higher degrees of fibrosis associated with lower hepatic ADC values. Moderate correlation between hepatic fibrosis and T(2) values was seen with higher degrees of fibrosis associated with lower T(2) values. Inverse relationships between degrees of fibrosis and both ADC and T(2) are seen, highlighting the utility of these parameters in the ongoing development of an MRI methodology to quantify hepatic fibrosis. Copyright © 2011 Wiley Periodicals, Inc.
Regier, M; Derlin, T; Schwarz, D; Laqmani, A; Henes, F O; Groth, M; Buhk, J-H; Kooijman, H; Adam, G
2012-10-01
To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm(2)) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV(mean)) and maximum (SUV(max)) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC(mean)) and minimum ADC (ADC(min)) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland-Altman and regression analysis were assessed. Data analysis revealed a significant inverse correlation of the ADC(min) and SUV(max) (r=-0.46; p=0.032). Testing the correlation of the ADC(min) and SUV(max) for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r=-0.47; p=0.03) and squamouscell carcinomas (r=-0.71; p=0.002), respectively. No significant correlation was found for the comparison of ADC(min) and SUV(mean) (r=-0.29; p=0.27), ADC(mean) vs. SUV(mean) (r=-0.28; p=0.31) or ADC(mean) vs. SUV(max) (r=-0.33; p=0.23). The κ-value of 0.88 indicated a good agreement between both observers. This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Jameson, A. R.
1990-01-01
The relationship between the rainfall rate (R) obtained from radiometric brightness temperatures and the extinction coefficient (k sub e) is investigated by computing the values of k sub e over a wide range of rainfall rates, for frequencies from 3 to 25 GHz. The results show that the strength of the relation between the R and the k sub e values exhibits considerable variation for frequencies at this range. Practical suggestions are made concerning the selection of particular frequencies for rain measurements to minimize the error in R determinations.
[Spectral reflectance characteristics and modeling of typical Takyr Solonetzs water content].
Zhang, Jun-hua; Jia, Ke-li
2015-03-01
Based on the analysis of the spectral reflectance of the typical Takyr Solonetzs soil in Ningxia, the relationship of soil water content and spectral reflectance was determined, and a quantitative model for the prediction of soil water content was constructed. The results showed that soil spectral reflectance decreased with the increasing soil water content when it was below the water holding capacity but increased with the increasing soil water content when it was higher than the water holding capacity. Soil water content presented significantly negative correlation with original reflectance (r), smooth reflectance (R), logarithm of reflectance (IgR), and positive correlation with the reciprocal of R and logarithm of reciprocal [lg (1/R)]. The correlation coefficient of soil water content and R in the whole wavelength was 0.0013, 0.0397 higher than r and lgR, respectively. Average correlation coefficient of soil water content with 1/R and [lg (1/R)] at the wavelength of 950-1000 nm was 0.2350 higher than that of 400-950 nm. The relationships of soil water content with the first derivate differential (R') , the first derivate differential of logarithm (lgR)' and the first derivate differential of logarithm of reciprocal [lg(1/R)]' were unstable. Base on the coefficients of r, lg(1/R), R' and (lgR)', different regression models were established to predict soil water content, and the coefficients of determination were 0.7610, 0.8184, 0.8524 and 0.8255, respectively. The determination coefficient for power function model of R'. reached 0.9447, while the fitting degree between the predicted value based on this model and on-site measured value was 0.8279. The model of R' had the highest fitted accuracy, while that of r had the lowest one. The results could provide a scientific basis for soil water content prediction and field irrigation in the Takyr Solonetzs region.
Sławik, Tomasz; Kowalski, Cezary
2002-04-05
The lipophilicity (R(Mo)) and specific hydrophobic surface area of seven 1,2-benzisothiazol-3(2H)-ones have been determined by reversed-phase TLC and the effect of different mobile-phase modifiers (acetone, acetonitrile, methanol) on the retention has been studied. The linear correlations between the volume fraction of the organic solvent and the R(M) values over a limited range were established for each solute with high values of correlation coefficients (>0.99). The influence of solvent pH on R(M) values was investigated.
Validation of the questionnaire on hand function assessment in leprosy.
Ferreira, Telma Leonel; Alvarez, Rosicler Rocha Aiza; Virmond, Marcos da Cunha Lopes
2012-06-01
To validate the psychometric properties of the questionnaire on hand function assessment in leprosy. Study conducted with a convenience sample of 101 consecutive patients in Brasília (Central-Western Brazil), from June 2008 to July 2009. The individuals were adults affected by leprosy, with impairment of the ulnar, median and radial nerves. Interobservers and intraobserver reproducibility was analyzed through successive interviews, and construct validity was analyzed through association between age, clinical form of leprosy, duration of nerve injury, grip and pinch strength measured with a dynamometer, sensibility test performed with Semmes-Weinstein monofilaments and manual ability assessment using the Jebsen test of hand function. Pondered kappa coefficient was calculated and a Bland-Altman plot was constructed to assess the reproducibility of the instrument. For internal consistency, Cronbach's alpha coefficient was utilized. Pearson's correlation coefficient was calculated and a multiple regression model was used. The pondered kappa values for interobservers and intraobserver assessments ranged from 0.86 to 0.97 and from 0.85 to 0.97, respectively. The value of Cronbach's alpha coefficient was 0.967. Pearson's correlation coefficient showed an association (p < 0.001) among duration of nerve injury, grip and pinch strength, cutaneous sensibility and mean score in the Jebsen Test. The mean score of the questionnaire on hand functional assessment in leprosy was associated with operational classification of leprosy, duration of nerve injury, grip strength, cutaneous sensibility and manual ability (p < 0.0001 for the model as a whole). The questionnaire on hand functional assessment in leprosy presents almost perfect interobservers and intraobserver reproducibility, high internal consistency and correlation with operational classification of leprosy, duration of nerve injury, grip strength, cutaneous sensibility in the hands and manual ability.
The influence of trading volume on market efficiency: The DCCA approach
NASA Astrophysics Data System (ADS)
Sukpitak, Jessada; Hengpunya, Varagorn
2016-09-01
For a single market, the cross-correlation between market efficiency and trading volume, which is an indicator of market liquidity, is attentively analysed. The study begins with creating time series of market efficiency by applying time-varying Hurst exponent with one year sliding window to daily closing prices. The time series of trading volume corresponding to the same time period used for the market efficiency is derived from one year moving average of daily trading volume. Subsequently, the detrended cross-correlation coefficient is employed to quantify the degree of cross-correlation between the two time series. It was found that values of cross-correlation coefficient of all considered stock markets are close to 0 and are clearly out of range in which correlation being considered significant in almost every time scale. Obtained results show that the market liquidity in term of trading volume hardly has effect on the market efficiency.
Coding stimulus amplitude by correlated neural activity
NASA Astrophysics Data System (ADS)
Metzen, Michael G.; Ávila-Åkerberg, Oscar; Chacron, Maurice J.
2015-04-01
While correlated activity is observed ubiquitously in the brain, its role in neural coding has remained controversial. Recent experimental results have demonstrated that correlated but not single-neuron activity can encode the detailed time course of the instantaneous amplitude (i.e., envelope) of a stimulus. These have furthermore demonstrated that such coding required and was optimal for a nonzero level of neural variability. However, a theoretical understanding of these results is still lacking. Here we provide a comprehensive theoretical framework explaining these experimental findings. Specifically, we use linear response theory to derive an expression relating the correlation coefficient to the instantaneous stimulus amplitude, which takes into account key single-neuron properties such as firing rate and variability as quantified by the coefficient of variation. The theoretical prediction was in excellent agreement with numerical simulations of various integrate-and-fire type neuron models for various parameter values. Further, we demonstrate a form of stochastic resonance as optimal coding of stimulus variance by correlated activity occurs for a nonzero value of noise intensity. Thus, our results provide a theoretical explanation of the phenomenon by which correlated but not single-neuron activity can code for stimulus amplitude and how key single-neuron properties such as firing rate and variability influence such coding. Correlation coding by correlated but not single-neuron activity is thus predicted to be a ubiquitous feature of sensory processing for neurons responding to weak input.
A new method to estimate average hourly global solar radiation on the horizontal surface
NASA Astrophysics Data System (ADS)
Pandey, Pramod K.; Soupir, Michelle L.
2012-10-01
A new model, Global Solar Radiation on Horizontal Surface (GSRHS), was developed to estimate the average hourly global solar radiation on the horizontal surfaces (Gh). The GSRHS model uses the transmission function (Tf,ij), which was developed to control hourly global solar radiation, for predicting solar radiation. The inputs of the model were: hour of day, day (Julian) of year, optimized parameter values, solar constant (H0), latitude, and longitude of the location of interest. The parameter values used in the model were optimized at a location (Albuquerque, NM), and these values were applied into the model for predicting average hourly global solar radiations at four different locations (Austin, TX; El Paso, TX; Desert Rock, NV; Seattle, WA) of the United States. The model performance was assessed using correlation coefficient (r), Mean Absolute Bias Error (MABE), Root Mean Square Error (RMSE), and coefficient of determinations (R2). The sensitivities of parameter to prediction were estimated. Results show that the model performed very well. The correlation coefficients (r) range from 0.96 to 0.99, while coefficients of determination (R2) range from 0.92 to 0.98. For daily and monthly prediction, error percentages (i.e. MABE and RMSE) were less than 20%. The approach we proposed here can be potentially useful for predicting average hourly global solar radiation on the horizontal surface for different locations, with the use of readily available data (i.e. latitude and longitude of the location) as inputs.
Molecular-dynamics simulation of mutual diffusion in nonideal liquid mixtures
NASA Astrophysics Data System (ADS)
Rowley, R. L.; Stoker, J. M.; Giles, N. F.
1991-05-01
The mutual-diffusion coefficients, D 12, of n-hexane, n-heptane, and n-octane in chloroform were modeled using equilibrium molecular-dynamics (MD) simulations of simple Lennard-Jones (LJ) fluids. Pure-component LJ parameters were obtained by comparison of simulations to experimental self-diffusion coefficients. While values of “effective” LJ parameters are not expected to simulate accurately diverse thermophysical properties over a wide range of conditions, it was recently shown that effective parameters obtained from pure self-diffusion coefficients can accurately model mutual diffusion in ideal, liquid mixtures. In this work, similar simulations are used to model diffusion in nonideal mixtures. The same combining rules used in the previous study for the cross-interaction parameters were found to be adequate to represent the composition dependence of D 12. The effect of alkane chain length on D 12 is also correctly predicted by the simulations. A commonly used assumption in empirical correlations of D 12, that its kinetic portion is a simple, compositional average of the intradiffusion coefficients, is inconsistent with the simulation results. In fact, the value of the kinetic portion of D 12 was often outside the range of values bracketed by the two intradiffusion coefficients for the nonideal system modeled here.
Identifying Bearing Rotodynamic Coefficients Using an Extended Kalman Filter
NASA Technical Reports Server (NTRS)
Miller, Brad A.; Howard, Samuel A.
2008-01-01
An Extended Kalman Filter is developed to estimate the linearized direct and indirect stiffness and damping force coefficients for bearings in rotor dynamic applications from noisy measurements of the shaft displacement in response to imbalance and impact excitation. The bearing properties are modeled as stochastic random variables using a Gauss-Markov model. Noise terms are introduced into the system model to account for all of the estimation error, including modeling errors and uncertainties and the propagation of measurement errors into the parameter estimates. The system model contains two user-defined parameters that can be tuned to improve the filter's performance; these parameters correspond to the covariance of the system and measurement noise variables. The filter is also strongly influenced by the initial values of the states and the error covariance matrix. The filter is demonstrated using numerically simulated data for a rotor bearing system with two identical bearings, which reduces the number of unknown linear dynamic coefficients to eight. The filter estimates for the direct damping coefficients and all four stiffness coefficients correlated well with actual values, whereas the estimates for the cross-coupled damping coefficients were the least accurate.
NASA Astrophysics Data System (ADS)
Shekaari, Hemayat; Mousavi, Sedighehnaz S.; Mansoori, Yagoub
2009-04-01
Osmotic coefficients, {φ}, electrical conductance data, Λ, and refractive indices, n D, of aqueous solutions of the ionic liquid, 1-pentyl-3-methylimidazolium chloride [PnMIm]Cl have been measured at T = (298.15, 308.15, 318.15, and 328.15) K. Measurements of osmotic coefficients were carried out by the vapor-pressure osmometry method (VPO). Osmotic coefficient values show that ion-solvent interactions are stronger at lower temperature. The osmotic coefficients were correlated to the Pitzer-ion interaction and modified NRTL (MNRTL) models. From these data, mean molal activity coefficients, γ±, and excess Gibbs free energies, G E, have been calculated. Electrical conductance data have been applied for determination of association constants, K a, and limiting molar conductances, Λ 0, using the low concentration chemical model (lcCM). Calculated ion-association constant, K a, values show that ion-association effects increase at high temperatures which is in agreement with osmotic coefficient results. Experimental results of refractive indices for the binary system are reported, and have been fitted by a polynomial expansion.
Rodríguez, A; Claverias, L; Marín, J; Magret, M; Rosich, S; Bodí, M; Trefler, S; Pascual, S; Gea, J
2015-03-01
To compare oxygen saturation index (rSO2) obtained simultaneously in two different brachial muscles. Prospective and observational study. Intensive care unit. Critically ill patients with community-acquired pneumonia. Two probes of NIRS device (INVOS 5100) were simultaneously placed on the brachioradialis (BR) and deltoid (D) muscles. rSO2 measurements were recorded at baseline (ICU admission) and at 24h. Demographic and clinical variables were registered. Pearson's correlation coefficient was used to assess the association between continuous variables. The consistency of the correlation was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plot. The predictive value of the rSO2 for mortality was calculated by ROC curve. Nineteen patients were included with an ICU mortality of 21.1%. The rSO2 values at baseline and at 24h were significantly higher in D than in BR muscle. Values obtained simultaneously in both limbs showed a strong correlation and adequate consistency: BR (r=0.95; p<0.001; ICC=0.94; 95% CI: 0.90-0.96; p<0.001), D (r=0.88; p=0.01; ICC=0.88; 95% CI: 0.80-0.90; p>0.001) but a wide limit of agreement. Non-survivors had rSO2 values significantly lower than survivors at all times of the study. No patient with rSO2 >60% in BR died, and only 17.6% died with an rSO2 value >60% in D. Both muscles showed consistent discriminatory power for mortality. Both BR and D muscles were appropriate for measuring rSO2. Copyright © 2013 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.
On the solar cycle variation in the barometer coefficients of high latitude neutron monitors
NASA Technical Reports Server (NTRS)
Kusunose, M.; Ogita, N.
1985-01-01
Evaluation of barometer coefficients of neutron monitors located at high latitudes has been performed by using the results of the spherical harmonic analysis based on the records from around twenty stations for twelve years from January 1966 to December 1977. The average of data at eight stations, where continuous records are available for twelve years, show that the absolute value of barometer coefficient is in positive correlation with the cosmic ray neutron intensity. The variation rate of the barometer coefficient to the cosmic ray neutron intensity is influenced by the changes in the cutoff rigidity and in the primary spectrum.
Abazov, Victor Mukhamedovich
2015-04-30
The recent paper on the charge asymmetry for electrons from W boson decay has an error in the Tables VII to XI that show the correlation coefficients of systematic uncertainties. Furthermore, the correlation matrix elements shown in the original publication were the square roots of the calculated values.
T.Z. Ye; K.J.S. Jayawickrama; G.R. Johnson
2006-01-01
Using computer simulation, we evaluated the impact of using first-generation information to increase selection efficiency in a second-generation breeding program. Selection efficiency was compared in terms of increase in rank correlation between estimated and true breeding values (i.e., ranking accuracy), reduction in coefficient of variation of correlation...
Spatial correlation of hydrometeor occurrence, reflectivity, and rain rate from CloudSat
NASA Astrophysics Data System (ADS)
Marchand, Roger
2012-03-01
This paper examines the along-track vertical and horizontal structure of hydrometeor occurrence, reflectivity, and column rain rate derived from CloudSat. The analysis assumes hydrometeors statistics in a given region are horizontally invariant, with the probability of hydrometeor co-occurrence obtained simply by determining the relative frequency at which hydrometeors can be found at two points (which may be at different altitudes and offset by a horizontal distance, Δx). A correlation function is introduced (gamma correlation) that normalizes hydrometeor co-occurrence values to the range of 1 to -1, with a value of 0 meaning uncorrelated in the usual sense. This correlation function is a generalization of the alpha overlap parameter that has been used in recent studies to describe the overlap between cloud (or hydrometeor) layers. Examples of joint histograms of reflectivity at two points are also examined. The analysis shows that the traditional linear (or Pearson) correlation coefficient provides a useful one-to-one measure of the strength of the relationship between hydrometeor reflectivity at two points in the horizontal (that is, two points at the same altitude). While also potentially useful in the vertical direction, the relationship between reflectivity values at different altitudes is not as well described by the linear correlation coefficient. The decrease in correlation of hydrometeor occurrence and reflectivity with horizontal distance, as well as precipitation occurrence and column rain rate, can be reasonably well fit with a simple two-parameter exponential model. In this paper, the North Pacific and tropical western Pacific are examined in detail, as is the zonal dependence.
Developing a Danish version of the "Impact on Participation and Autonomy Questionnaire".
Ghaziani, Emma; Krogh, Anne Grethe; Lund, Hans
2013-05-01
To translate the "Impact on Participation and Autonomy Questionnaire" into Danish (IPAQ-DK), and estimate its internal consistency and test-retest reliability in order to promote participation-based interventions and research. Translation and two successive reliability assessments through test-retest. 137 adults with varying degrees of impairment; of these, 67 participated in the final reliability assessment. The translation followed guidelines set forth by the "European Group for Quality of Life Assessment and Health Measurement". Internal consistency for subscales was estimated by Chronbach's alpha. Weighted kappa coefficients and intraclass correlation coefficients were calculated to assess the test-retest reliability at item and subscale level, respectively. A preliminary reliability assessment revealed residual issues regarding the translation and cultural adaptation of the instrument. The revised version (IPAQ-DK) was subsequently subjected to a similar assessment demonstrating Chronbach's alpha values from 0.698 to 0.817. Weighted kappa ranged from 0.370 to 0.880; 78% of these values were higher than 0.600. The intraclass correlation coefficient covered values from 0.701 to 0.818. IPAQ-DK is a useful instrument for identifying person-perceived participation restrictions and satisfaction with participation. Further studies of IPAQ-DK's floor/ceiling effects and responsiveness to change are recommended, and whether there is a need for further linguistic improvement of certain items.
Model for the partition of neutral compounds between n-heptane and formamide.
Karunasekara, Thushara; Poole, Colin F
2010-04-01
Partition coefficients for 84 varied compounds were determined for n-heptane-formamide biphasic partition system and used to derive a model for the distribution of neutral compounds between the n-heptane-rich and formamide-rich layers. The partition coefficients, log K(p), were correlated through the solvation parameter model giving log K(p)=0.083+0.559E-2.244S-3.250A-1.614B+2.387V with a multiple correlation coefficient of 0.996, standard error of the estimate 0.139, and Fisher statistic 1791. In the model, the solute descriptors are excess molar refraction, E, dipolarity/polarizability, S, overall hydrogen-bond acidity, A, overall hydrogen-bond basicity, B, and McGowan's characteristic volume, V. The model is expected to be able to estimate further values of the partition coefficient to about 0.13 log units for the same descriptor space covered by the calibration compounds (E=-0.26-2.29, S=0-1.93, A=0-1.25, B=0.02-1.58, and V=0.78-2.50). The n-heptane-formamide partition system is shown to have different selectivity to other totally organic biphasic systems and to be suitable for estimating descriptor values for compounds of low water solubility and/or stability.
[Evaluation of the Abbott Cell-Dyn Sapphire hematology analyzer].
Park, Younhee; Song, Jaewoo; Song, Sungwook; Song, Kyung Soon; Ahn, Mee Suk; Yang, Mi-Sook; Kim, Il; Choi, Jong Rak
2007-06-01
The performance of Cell-Dyn Sapphire (Abbott Diagnostic, USA) was compared to the Bayer Advia 2120 (Bayer Diagnostics, USA), Sysmex XE-2100 (Sysmex Corporation, Japan), and reference microscopy. Three hundred samples for routine CBC and WBC differentials were randomly chosen for a comparison analysis. The Cell-Dyn Sapphire system was evaluated according to the linearity, imprecision, inter-instrument correlations, and white blood cell differential. The CBC parameters (WBC, RBC, hemoglobin and platelet) showed a significant linearity with correlation coefficients greater than 0.99 (P<0.0001). Coefficients of variation (CV) for within-run and differential count of WBC were less than 5% except for Total CV for monocytes, eosinophils, and basophils and within-run CV for low valued eosinophils. The correlation coefficients with manual count were lower in monocytes, eosinophils, and basophils than in neutrophils and lymphocytes. The correlation with other hematology anlayzers was significant exclusive of basophils. These results demonstrate that the Cell-Dyn Sapphire has a good linearity, an acceptable reproducibility, a minimal carryover, and a comparable performance with the sysmex XE-2100 and Advia 2120.
Zhang, Yun-lin; Qin, Bo-qiang; Ma, Rong-hua; Zhu, Guang-wei; Zhang, Lu; Chen, Wei-min
2005-03-01
Chromophoric dissolved organic matter (CDOM) represents one of the primary light-absorbing species in natural waters and plays a critical in determining the aquatic light field. CDOM shows a featureless absorption spectrum that increases exponentially with decreasing wavelength, which limits the penetration of biologically damaging UV-B radiation (wavelength from 280 to 320 nm) in the water column, thus shielding aquatic organisms. CDOM absorption measurements and their relationship with dissolved organic carbon (DOC), and fluorescence are presented in typical macrophyte and algae lake zone of Lake Taihu based on a field investigation in April in 2004 and lab analysis. Absorption spectral of CDOM was measured from 240 to 800 nm using a Shimadzu UV-2401PC UV-Vis recording spectrophotometer. Fluorescence with an excitation wavelength of 355 nm, an emission wavelength of 450 nm is measured using a Shimadzu 5301 spectrofluorometer. Concentrations of DOC ranged from 6.3 to 17.2 mg/L with an average of 9.08 +/- 2.66 mg/L. CDOM absorption coefficients at 280 nm and 355 nm were in the range of 11.2 - 32.6 m(-1) (average 17.46m(-1) +/- 5.75 m(-1) and 2.4 - 8.3 m(-1) (average 4.17m(-1) +/- 1.47 m(-l)), respectively. The values of the DOC-specific absorption coefficient at 355 nm ranged from 0.31 to 0.64 L x (mg x m)-1. Fluorescence emission at 450 nm, excited at 355 nm, had a mean value of 1.32nm(-1) +/- 0.84 nm(-1). A significant lake zone difference is found in DOC concentration, CDOM absorption coefficient and fluorescence, but not in DOC-specific absorption coefficient and spectral slope coefficient. This regional distribution pattern is in agreement with the location of sources of yellow substance: highest concentrations close to river mouth under the influence of river inflow, lower values in East Lake Taihu. The values of algae lake zone are obvious larger than those of macrophyte lake zone. In Meiliang Bay, CDOM absorption, DOC concentration and fluorescence tend to decreasing from inside to mouth of the Bay. The results show a good correlation between CDOM absorption and DOC coefficients during 280 - 500 nm short wavelength intervals. The R-square coefficient between CDOM absorption and DOC concentration decreases with the increase of wavelength from 280 to 500 nm. The significant linear regression correlations between fluorescence, DOC concentration and absorption coefficients were found at 355 nm. The exponential slope coefficients ranged from 13.0 to 16.4 microm(-1) with a mean value 14.37microm(-1) +/- 0.73microm(-1), 17.3microm(-1) - 20.3microm(-1) with a mean value 19.17microm(-1) +/- 0.84microm(-1) and 12.0microm(-1) - 15.8microm(-1) with a mean value 13.38microm(-1) +/- 0.82microm(-1) over the 280 - 500 nm, 280 - 360 nm and 360 - 440 nm intervals.
NASA Astrophysics Data System (ADS)
Mahanta, Upakul; Goswami, Aruna; Duorah, Hiralal; Duorah, Kalpana
2017-08-01
Elemental abundance patterns of globular cluster stars can provide important clues for understanding cluster formation and early chemical evolution. The origin of the abundance patterns, however, still remains poorly understood. We have studied the impact of p-capture reaction cycles on the abundances of oxygen, sodium and aluminium considering nuclear reaction cycles of carbon-nitrogen-oxygen-fluorine, neon-sodium and magnesium-aluminium in massive stars in stellar conditions of temperature range 2×107 to 10×107 K and typical density of 102 gm cc-1. We have estimated abundances of oxygen, sodium and aluminium with respect to Fe, which are then assumed to be ejected from those stars because of rotation reaching a critical limit. These ejected abundances of elements are then compared with their counterparts that have been observed in some metal-poor evolved stars, mainly giants and red giants, of globular clusters M3, M4, M13 and NGC 6752. We observe an excellent agreement with [O/Fe] between the estimated and observed abundance values for globular clusters M3 and M4 with a correlation coefficient above 0.9 and a strong linear correlation for the remaining two clusters with a correlation coefficient above 0.7. The estimated [Na/Fe] is found to have a correlation coefficient above 0.7, thus implying a strong correlation for all four globular clusters. As far as [Al/Fe] is concerned, it also shows a strong correlation between the estimated abundance and the observed abundance for globular clusters M13 and NGC 6752, since here also the correlation coefficient is above 0.7 whereas for globular cluster M4 there is a moderate correlation found with a correlation coefficient above 0.6. Possible sources of these discrepancies are discussed.
Ground reaction force analysed with correlation coefficient matrix in group of stroke patients.
Szczerbik, Ewa; Krawczyk, Maciej; Syczewska, Małgorzata
2014-01-01
Stroke is the third cause of death in contemporary society and causes many disorders. Clinical scales, ground reaction force (GRF) and objective gait analysis are used for assessment of patient's rehabilitation progress during treatment. The goal of this paper is to assess whether signal correlation coefficient matrix applied to GRF can be used for evaluation of the status of post-stroke patients. A group of patients underwent clinical assessment and instrumented gait analysis simultaneously three times. The difference between components of patient's GRF (vertical, fore/aft, med/lat) and normal ones (reference GRF of healthy subjects) was calculated as correlation coefficient. Patients were divided into two groups ("worse" and "better") based on the clinical functional scale tests done at the beginning of rehabilitation process. The results obtained by these two groups were compared using statistical analysis. An increase of median value of correlation coefficient is observed in all components of GRF, but only in non-paretic leg. Analysis of GRF signal can be helpful in assessment of post-stroke patients during rehabilitation. Improvement in stroke patients was observed in non-paretic leg of the "worse" group. GRF analysis should not be the only tool for objective validation of patient's improvement, but could be used as additional source of information.
Kitagawa, Yasuhisa; Teramoto, Tamio; Daida, Hiroyuki
2012-01-01
We evaluated the impact of adherence to preferable behavior on serum lipid control assessed by a self-reported questionnaire in high-risk patients taking pravastatin for primary prevention of coronary artery disease. High-risk patients taking pravastatin were followed for 2 years. Questionnaire surveys comprising 21 questions, including 18 questions concerning awareness of health, and current status of diet, exercise, and drug therapy, were conducted at baseline and after 1 year. Potential domains were established by factor analysis from the results of questionnaires, and adherence scores were calculated in each domain. The relationship between adherence scores and lipid values during the 1-year treatment period was analyzed by each domain using multiple regression analysis. A total of 5,792 patients taking pravastatin were included in the analysis. Multiple regression analysis showed a significant correlation in terms of "Intake of high fat/cholesterol/sugar foods" (regression coefficient -0.58, p=0.0105) and "Adherence to instructions for drug therapy" (regression coefficient -6.61, p<0.0001). Low-density lipoprotein cholesterol (LDL-C) values were significantly lower in patients who had an increase in the adherence score in the "Awareness of health" domain compared with those with a decreased score. There was a significant correlation between high-density lipoprotein (HDL-C) values and "Awareness of health" (regression coefficient 0.26; p= 0.0037), "Preferable dietary behaviors" (regression coefficient 0.75; p<0.0001), and "Exercise" (regression coefficient 0.73; p= 0.0002). Similar relations were seen with triglycerides. In patients who have a high awareness of their health, a positive attitude toward lipid-lowering treatment including diet, exercise, and high adherence to drug therapy, is related with favorable overall lipid control even in patients under treatment with pravastatin.
2013-01-01
Background Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. Results A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham’s π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. Conclusion The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/− 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale. PMID:24289110
Klöckner, Wolf; Gacem, Riad; Anderlei, Tibor; Raven, Nicole; Schillberg, Stefan; Lattermann, Clemens; Büchs, Jochen
2013-12-02
Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham's π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/- 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale.
Correlation of apparent diffusion coefficient ratio on 3.0 T MRI with prostate cancer Gleason score.
Jyoti, Rajeev; Jain, Tarun Pankaj; Haxhimolla, Hodo; Liddell, Heath; Barrett, Sean Edward
2018-01-01
The purpose was to investigate the usefulness of ADC ratio on Diffusion MRI to discriminate between benign and malignant lesions of Prostate. Images of patients who underwent in-gantry MRI guided prostate lesion biopsy were retrospectively analyzed. Prostate Cancers with 20% or more Gleason score (GS) pattern 3 + 3 = 6 in each core or any volume of higher Gleason score pattern were included. ADC ratio was calculated by two reviewers for each lesion. The ADC ratio was calculated for each lesion by dividing the lowest ADC value in a lesion and highest ADC value in normal prostate in peripheral zone (PZ). ADC ratio values were compared with the biopsy result. Data was analysed using independent samples T-test, Spearman correlation, intra-class correlation coefficient (ICC) and Receiver operating characteristic (ROC) curve. 45 lesions in 33 patients were analyzed. 12 lesions were in transitional zone (TZ) and 33 in perpheral zone PZ. All lesions demonstrated an ADC ratio of 0.45 or lower. GS demonstrated a negative correlation with both the ADC value and ADC ratio . However, ADC ratio (p < 0.001) demonstrated a stronger correlation compared to ADC value alone (p = 0.014). There was no significant statistical difference between GS 3 + 4 and GS 4 + 3 mean ADC tumour value (p = 0.167). However when using ADC ratio , there was a significant difference (p = 0.032). ROC curve analysis demonstrated an area under the curve of 0.83 using ADC ratio and 0.76 when using ADC tumour value when discriminating Gleason 6 from Gleason ≥7 tumours. Inter-observer reliability in the calculation of ADC ratios was excellent, with ICC of 0.964. ADC ratio is a reliable and reproducible tool in quantification of diffusion restriction for clinically significant prostate cancer foci.
A Method of Q-Matrix Validation for the Linear Logistic Test Model
Baghaei, Purya; Hohensinn, Christine
2017-01-01
The linear logistic test model (LLTM) is a well-recognized psychometric model for examining the components of difficulty in cognitive tests and validating construct theories. The plausibility of the construct model, summarized in a matrix of weights, known as the Q-matrix or weight matrix, is tested by (1) comparing the fit of LLTM with the fit of the Rasch model (RM) using the likelihood ratio (LR) test and (2) by examining the correlation between the Rasch model item parameters and LLTM reconstructed item parameters. The problem with the LR test is that it is almost always significant and, consequently, LLTM is rejected. The drawback of examining the correlation coefficient is that there is no cut-off value or lower bound for the magnitude of the correlation coefficient. In this article we suggest a simulation method to set a minimum benchmark for the correlation between item parameters from the Rasch model and those reconstructed by the LLTM. If the cognitive model is valid then the correlation coefficient between the RM-based item parameters and the LLTM-reconstructed item parameters derived from the theoretical weight matrix should be greater than those derived from the simulated matrices. PMID:28611721
Statistical hypothesis tests of some micrometeorological observations
DOE Office of Scientific and Technical Information (OSTI.GOV)
SethuRaman, S.; Tichler, J.
Chi-square goodness-of-fit is used to test the hypothesis that the medium scale of turbulence in the atmospheric surface layer is normally distributed. Coefficients of skewness and excess are computed from the data. If the data are not normal, these coefficients are used in Edgeworth's asymptotic expansion of Gram-Charlier series to determine an altrnate probability density function. The observed data are then compared with the modified probability densities and the new chi-square values computed.Seventy percent of the data analyzed was either normal or approximatley normal. The coefficient of skewness g/sub 1/ has a good correlation with the chi-square values. Events withmore » vertical-barg/sub 1/vertical-bar<0.21 were normal to begin with and those with 0.21« less
CALIOP near-real-time backscatter products compared to EARLINET data
NASA Astrophysics Data System (ADS)
Grigas, T.; Hervo, M.; Gimmestad, G.; Forrister, H.; Schneider, P.; Preißler, J.; Tarrason, L.; O'Dowd, C.
2015-03-01
The expedited near-real-time Level 1.5 Cloud-Aerosol Lidar (Light Detection and Ranging) with Orthogonal Polarization (CALIOP) products were evaluated against data from the ground-based European Aerosol Research Lidar Network (EARLINET). Over a period of three years, lidar data from 48 CALIOP overpasses with ground tracks within a 100 km distance from an operating EARLINET station were deemed suitable for analysis and they included a valid aerosol classification type (e.g. dust, polluted dust, clean marine, clean continental, polluted continental, mixed and/or smoke/biomass burning). For the complete dataset comprising both PBL and FT data, the correlation coefficient was 0.86, and when separated into separate layers, the PBL and FT correlation coefficients were 0.6 and 0.85 respectively. The presence of FT layers with high attenuated backscatter led to poor agreement in PBL backscatter profiles between the CALIOP and EARLINET measurements and prompted a further analysis filtering out such cases. However, the correlation coefficient value for the complete dataset decreased marginally from 0.86 to 0.84 while the PBL coefficient increased from 0.6 up to 0.65 and the FT coefficient also decreased from 0.85 to 0.79. For specific aerosol types, the correlation coefficient between CALIOP backscatter profiles and ground-based lidar data ranged from 0.37 for polluted continental aerosol in the planetary boundary layer (PBL) to 0.57 for dust in the free troposphere (FT). The results suggest different levels of agreement based on the location of the dominant aerosol layer and the aerosol type.
Poulson, S R; Drever, J I; Colberg, P J
1997-11-01
Sorption partition coefficients between water and organic carbon (Koc) for deuterated benzene, toluene, and ethylbenzene have been estimated by measuring values of the octanol-water partition coefficient (Kow) and HPLC retention factors (k1), which correlate closely to values of Koc. Measured values of log Kow for non-deuterated and deuterated toluene are 2.77 (+/- 0.02) and 2.78 (+/- 0.04), respectively, indicating that within experimental error, log Koc for deuterated and non-deuterated toluene are the same. The HPLC method provides greater precision, and yields values of delta log Koc (= log Koc [deuterated]-log Koc [non-deuterated]) of -0.021 (+/- 0.001) for benzene, -0.028 (+/- 0.002) for toluene, and -0.035 (+/- 0.003) for ethylbenzene. The small values of delta log Koc demonstrates that deuterated compounds are excellent tracers for the hydrologic behavior of ground water contaminants.
An efficient algorithm for generating random number pairs drawn from a bivariate normal distribution
NASA Technical Reports Server (NTRS)
Campbell, C. W.
1983-01-01
An efficient algorithm for generating random number pairs from a bivariate normal distribution was developed. Any desired value of the two means, two standard deviations, and correlation coefficient can be selected. Theoretically the technique is exact and in practice its accuracy is limited only by the quality of the uniform distribution random number generator, inaccuracies in computer function evaluation, and arithmetic. A FORTRAN routine was written to check the algorithm and good accuracy was obtained. Some small errors in the correlation coefficient were observed to vary in a surprisingly regular manner. A simple model was developed which explained the qualities aspects of the errors.
Au Eong, K G; Chan, E W; Luo, N; Wong, S H; Tan, N W H; Lim, T H; Wagle, A M
2012-01-01
Background/aims Utility values of age-related macular degeneration (AMD) in Asian patients are unknown. This study aims to assess utility values and construct validity of the EuroQOL-5D (EQ-5D), time trade-off (TTO), and standard gamble (SG) instruments in the Singapore multi-ethnic AMD population. Methods Cross-sectional, two-centre, institution-based study. Visual acuity (VA), clinical AMD severity, and utility scores on the EQ-5D, TTO, and SG were obtained from 338 AMD patients. VA was analysed in terms of the better-seeing eye (BEVA), worse-seeing eye (WEVA), and weighted average of both eyes (WVA). We evaluated SG on the perfect health-death (SG(death)) and binocular perfect vision-binocular blindness (SG(blindness)) scales. Construct validity was determined by testing a priorihypotheses relating the EQ-5D, TTO, and SG utility scores to VA and clinical AMD severity. Results The mean utilities on the EQ-5D, TTO, SG(death), and SG(blindness) were 0.89, 0.81, 0.86, and 0.90, respectively. EQ-5D scores correlated weakly with BEVA, WEVA, and WVA (Pearson's correlation coefficients −0.291, −0.247, and −0.305 respectively, P<0.001 for all). SG(death) and SG(blindness) demonstrated no correlation with BEVA, WEVA, or WVA (Pearson's correlation coefficients, range −0.06 to −0.125). TTO showed weak association only with WEVA and WVA (correlation coefficients −0.237, −0.228, P<0.0001), but not with BEVA (correlation coefficient −0.161). Clinical AMD severity correlated with EQ-5D and SG(death), but not with TTO and SG(blindness) (P=0.004, 0.002, 0.235, and 0.069, respectively). Conclusions AMD has a negative impact on utilities, although utility scores were high compared with Western cohorts. EQ-5D, TTO, and SG showed suboptimal construct validity, suggesting that health status utilities may not be sufficiently robust for cost-utility analyses in this population. PMID:22222257
Dissecting random and systematic differences between noisy composite data sets.
Diederichs, Kay
2017-04-01
Composite data sets measured on different objects are usually affected by random errors, but may also be influenced by systematic (genuine) differences in the objects themselves, or the experimental conditions. If the individual measurements forming each data set are quantitative and approximately normally distributed, a correlation coefficient is often used to compare data sets. However, the relations between data sets are not obvious from the matrix of pairwise correlations since the numerical value of the correlation coefficient is lowered by both random and systematic differences between the data sets. This work presents a multidimensional scaling analysis of the pairwise correlation coefficients which places data sets into a unit sphere within low-dimensional space, at a position given by their CC* values [as defined by Karplus & Diederichs (2012), Science, 336, 1030-1033] in the radial direction and by their systematic differences in one or more angular directions. This dimensionality reduction can not only be used for classification purposes, but also to derive data-set relations on a continuous scale. Projecting the arrangement of data sets onto the subspace spanned by systematic differences (the surface of a unit sphere) allows, irrespective of the random-error levels, the identification of clusters of closely related data sets. The method gains power with increasing numbers of data sets. It is illustrated with an example from low signal-to-noise ratio image processing, and an application in macromolecular crystallography is shown, but the approach is completely general and thus should be widely applicable.
NASA Astrophysics Data System (ADS)
Lalneihpuii, R.; Shrivastava, Ruchi; Mishra, Raj Kumar
2018-05-01
Using statistical mechanical model with square-well (SW) interatomic potential within the frame work of mean spherical approximation, we determine the composition dependent microscopic correlation functions, interdiffusion coefficients, surface tension and chemical ordering in Ag-Cu melts. Further Dzugutov universal scaling law of normalized diffusion is verified with SW potential in binary mixtures. We find that the excess entropy scaling law is valid for SW binary melts. The partial and total structure factors in the attractive and repulsive regions of the interacting potential are evaluated and then Fourier transformed to get partial and total radial distribution functions. A good agreement between theoretical and experimental values for total structure factor and the reduced radial distribution function are observed, which consolidates our model calculations. The well-known Bhatia-Thornton correlation functions are also computed for Ag-Cu melts. The concentration-concentration correlations in the long wavelength limit in liquid Ag-Cu alloys have been analytically derived through the long wavelength limit of partial correlation functions and apply it to demonstrate the chemical ordering and interdiffusion coefficients in binary liquid alloys. We also investigate the concentration dependent viscosity coefficients and surface tension using the computed diffusion data in these alloys. Our computed results for structure, transport and surface properties of liquid Ag-Cu alloys obtained with square-well interatomic interaction are fully consistent with their corresponding experimental values.
Li, Hai Ming; Liu, Jia; Qiang, Jin Wei; Gu, Wei Yong; Zhang, Guo Fu; Ma, Feng Hua
2017-11-01
This study aimed to investigate the conventional magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) features of endometrial stromal sarcoma (ESS) including a preliminary investigation of the correlation between the apparent diffusion coefficient (ADC) value and Ki-67 expression. The clinical and MRI data of 15 patients with ESS confirmed by surgery and pathology were analyzed retrospectively. The conventional MR morphological features, signal intensity on DWI, ADC value (n = 14), and clinicopathological marker Ki-67 (n = 13) were evaluated. Of 15 patients with ESS, 13 tumors were low-grade ESS (LGESS), and the remaining 2 were high-grade ESS (HGESS); 9 tumors were located in the myometrium, 5 were located in the endometrium and/or cervical canal, and 1 was located in extrauterine. Thirteen (87%) of 15 tumors showed a homo- or heterogeneous isointensity on T1-weighted imaging and a heterogeneous hyperintensity on T2-weighted imaging. The hypointense bands were observed in 11 tumors (73%) on T2-weighted imaging. The degenerations (cystic/necrosis/hemorrhage) were observed in 7 LGESS tumors and 2 HGESS tumors. The DWI hyperintensity was observed in 13 tumors (93%) and isointensity in remaining 1. The mean ADC value of the solid components in 14 ESSs was (1.05 ± 0.20) × 10mm/s. The contrast-enhanced MRI showed an obvious enhancement in 14 tumors (93%) (heterogeneous in 7 LGESSs and 2 HGESSs; homogeneous in 5 LGESSs). The ADC value was inversely correlated with the Ki-67 expression (r = -0.613, P = 0.026). Patients with ESS showed some characteristics on conventional MRI and DWI, and there was an inverse correlation between the ADC value and Ki-67 expression.
Drabik, Dominik; Przybyło, Magda; Sikorski, Aleksander; Langner, Marek
2016-03-01
Fluorescence Correlation Spectroscopy (FCS) is a technique, which allows determination of the diffusion coefficient and concentration of fluorescent objects suspended in the solution. The measured parameter is the fluctuation of the fluorescence signal emitted by diffusing molecules. When 100 nm DOPC vesicles labeled with various fluorescent dyes (Fluorescein-PE, NBD-PE, Atto488 DOPE or βBodipy FL) were measured, different values of diffusion coefficients have been obtained. These diffusion coefficients were different from the expected values measured using the dynamic light scattering method (DLS). The FCS was initially developed for solutions containing small fluorescent molecules therefore the observed inconsistency may result from the nature of vesicle suspension itself. The duration of the fluorescence signal may depend on the following factors: the exposure time of the labeled object to the excitation beam, the photo-physical properties (e.g., stability) of a fluorophore, the theoretical model used for the calculations of the diffusion coefficient and optical properties of the vesicle suspension. The diffusion coefficients determined for differently labeled liposomes show that its dependence on vesicle size and quantity of fluorescent probed used for labeling was significant demonstrating that the fluorescence properties of the fluorophore itself (bleaching and/or blinking) were critical factors for a correct outcome of FCS experiment. The new, based on combined FCS and DLS measurements, method for the determination of the focal volume prove itself to be useful for the evaluation of a fluorescence dye with respect to its applicability for FCS experiment.
Advanced Statistical Analyses to Reduce Inconsistency of Bond Strength Data.
Minamino, T; Mine, A; Shintani, A; Higashi, M; Kawaguchi-Uemura, A; Kabetani, T; Hagino, R; Imai, D; Tajiri, Y; Matsumoto, M; Yatani, H
2017-11-01
This study was designed to clarify the interrelationship of factors that affect the value of microtensile bond strength (µTBS), focusing on nondestructive testing by which information of the specimens can be stored and quantified. µTBS test specimens were prepared from 10 noncarious human molars. Six factors of µTBS test specimens were evaluated: presence of voids at the interface, X-ray absorption coefficient of resin, X-ray absorption coefficient of dentin, length of dentin part, size of adhesion area, and individual differences of teeth. All specimens were observed nondestructively by optical coherence tomography and micro-computed tomography before µTBS testing. After µTBS testing, the effect of these factors on µTBS data was analyzed by the general linear model, linear mixed effects regression model, and nonlinear regression model with 95% confidence intervals. By the general linear model, a significant difference in individual differences of teeth was observed ( P < 0.001). A significantly positive correlation was shown between µTBS and length of dentin part ( P < 0.001); however, there was no significant nonlinearity ( P = 0.157). Moreover, a significantly negative correlation was observed between µTBS and size of adhesion area ( P = 0.001), with significant nonlinearity ( P = 0.014). No correlation was observed between µTBS and X-ray absorption coefficient of resin ( P = 0.147), and there was no significant nonlinearity ( P = 0.089). Additionally, a significantly positive correlation was observed between µTBS and X-ray absorption coefficient of dentin ( P = 0.022), with significant nonlinearity ( P = 0.036). A significant difference was also observed between the presence and absence of voids by linear mixed effects regression analysis. Our results showed correlations between various parameters of tooth specimens and µTBS data. To evaluate the performance of the adhesive more precisely, the effect of tooth variability and a method to reduce variation in bond strength values should also be considered.
Evaluation of an eddy resolving global model at the Bermuda Atlantic Time-series Study site
NASA Astrophysics Data System (ADS)
Hiron, L.; Goncalves Neto, A.; Bates, N. R.; Johnson, R. J.
2016-02-01
The Bermuda Atlantic Time-series Study (BATS) commenced monthly sampling in 1988 and thus provides an invaluable 27 years of ocean temperature and salinity profiles for inferring climate relevant processes. However, the passage of mesoscale eddies through this site complicates the local heat and salinity budgets due to inadequate spatial and temporal sampling of these eddy systems. Thus, application of high resolution operational numerical models potentially offers a framework for estimating the horizontal transport due to mesoscale processes. The goal of this research was to analyze the accuracy of the MERCATOR operational 1/12° global ocean model at the BATS site by comparing temperature, salinity and heat budgets for years 2008 - 2015. Overall agreement in the upper 540m for temperature and salinity is found to be very encouraging with significant (P< 0.01) correlations at all depths for both fields. The highest value of correlation coefficient for the temperature field is 0.98 at the surface which decreases to 0.66 at 150m and then reaches a minimum of 0.50 at 320 to 540m. Similarly, the highest correlation coefficient for salinity is found at the surface, with a value of 0.83 and then decreases to a minimum of 0.25 in the subtropical mode water though then increases to 0.5 at 540m. Mixing in the MERCATOR model is also very well captured with a mixed layer depth (MLD) correlation coefficient of 0.92 for the seven year period. Finally, the total heat budget (0-540m) from MERCATOR varies coherently with the BATS observations as shown by a high correlation coefficient of 0.84 (P < 0.01). According to these analyses, daily output from the MERCATOR model represents accurately the temperature, salinity, heat budget and MLD at the BATS site. We propose this model can be used in future research at the BATS site by providing information about mesoscale structure and importantly, advective fluxes at this site.
Windschuh, Johannes; Meissner, Jan-Eric; Zaiss, Moritz; Eidel, Oliver; Kickingereder, Philipp; Nowosielski, Martha; Wiestler, Benedikt; Sahm, Felix; Floca, Ralf Omar; Neumann, Jan-Oliver; Wick, Wolfgang; Heiland, Sabine; Bendszus, Martin; Schlemmer, Heinz-Peter; Ladd, Mark Edward; Bachert, Peter; Radbruch, Alexander
2015-01-01
Objective To explore the correlation between Nuclear Overhauser Enhancement (NOE)-mediated signals and tumor cellularity in glioblastoma utilizing the apparent diffusion coefficient (ADC) and cell density from histologic specimens. NOE is one type of chemical exchange saturation transfer (CEST) that originates from mobile macromolecules such as proteins and might be associated with tumor cellularity via altered protein synthesis in proliferating cells. Patients and Methods For 15 patients with newly diagnosed glioblastoma, NOE-mediated CEST-contrast was acquired at 7 Tesla (asymmetric magnetization transfer ratio (MTRasym) at 3.3ppm, B1 = 0.7 μT). Contrast enhanced T1 (CE-T1), T2 and diffusion-weighted MRI (DWI) were acquired at 3 Tesla and coregistered. The T2 edema and the CE-T1 tumor were segmented. ADC and MTRasym values within both regions of interest were correlated voxelwise yielding the correlation coefficient rSpearman (rSp). In three patients who underwent stereotactic biopsy, cell density of 12 specimens per patient was correlated with corresponding MTRasym and ADC values of the biopsy site. Results Eight of 15 patients showed a weak or moderate positive correlation of MTRasym and ADC within the T2 edema (0.16≤rSp≤0.53, p<0.05). Seven correlations were statistically insignificant (p>0.05, n = 4) or yielded rSp≈0 (p<0.05, n = 3). No trend towards a correlation between MTRasym and ADC was found in CE-T1 tumor (-0.31
Paech, Daniel; Burth, Sina; Windschuh, Johannes; Meissner, Jan-Eric; Zaiss, Moritz; Eidel, Oliver; Kickingereder, Philipp; Nowosielski, Martha; Wiestler, Benedikt; Sahm, Felix; Floca, Ralf Omar; Neumann, Jan-Oliver; Wick, Wolfgang; Heiland, Sabine; Bendszus, Martin; Schlemmer, Heinz-Peter; Ladd, Mark Edward; Bachert, Peter; Radbruch, Alexander
2015-01-01
To explore the correlation between Nuclear Overhauser Enhancement (NOE)-mediated signals and tumor cellularity in glioblastoma utilizing the apparent diffusion coefficient (ADC) and cell density from histologic specimens. NOE is one type of chemical exchange saturation transfer (CEST) that originates from mobile macromolecules such as proteins and might be associated with tumor cellularity via altered protein synthesis in proliferating cells. For 15 patients with newly diagnosed glioblastoma, NOE-mediated CEST-contrast was acquired at 7 Tesla (asymmetric magnetization transfer ratio (MTRasym) at 3.3ppm, B1 = 0.7 μT). Contrast enhanced T1 (CE-T1), T2 and diffusion-weighted MRI (DWI) were acquired at 3 Tesla and coregistered. The T2 edema and the CE-T1 tumor were segmented. ADC and MTRasym values within both regions of interest were correlated voxelwise yielding the correlation coefficient rSpearman (rSp). In three patients who underwent stereotactic biopsy, cell density of 12 specimens per patient was correlated with corresponding MTRasym and ADC values of the biopsy site. Eight of 15 patients showed a weak or moderate positive correlation of MTRasym and ADC within the T2 edema (0.16≤rSp≤0.53, p<0.05). Seven correlations were statistically insignificant (p>0.05, n = 4) or yielded rSp≈0 (p<0.05, n = 3). No trend towards a correlation between MTRasym and ADC was found in CE-T1 tumor (-0.31
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roper, V.P.; Kobayashi, R.
1988-02-01
Infinite-dilution fugacity coefficients were obtained for the system fluorene/phenanthrene at thirteen temperatures by fitting total pressure across the entire mole fraction range by a computer routine. A thermodynamically consistent routine, that allowed for both positive and negative pressure deviations from the ideal values, was used to correlate data over the full mole fraction range from 0 to 1. The four-suffix Margules activity coefficient model without modification essentially served this purpose since total pressures and total pressure derivatives with respect to mole fraction were negligible compared to pressure measurement precision. The water/ethanol system and binary systems comprised of aniline, chlorobenzene, acetonitrilemore » and other polar compounds were fit for total pressure across the entire mole fraction range for binary Vapor-Liquid-Equilbria (VLE) using the rigorous, thermodynamically consistent Gibbs-Duhem Relation derived by Ibl and Dodge. Data correlation was performed using a computer least squares procedure. Infinite-dilution fugacity coefficients were obtained using a modified Margules activity coefficient model.« less
Monitoring Auroral Electrojet from Polar Cap Stations
NASA Astrophysics Data System (ADS)
Tan, A.; Lyatsky, W.; Lyatskaya, S.
2004-12-01
The auroral electrojet AL and AE geomagnetic activity indices are important for monitoring geomagnetic substorms. In the northern hemisphere these indices are derived from measurements at a set of geomagnetic observatories located in the auroral zone. In the southern hemisphere the major portion of the auroral zone is located on the ocean; this does not allow us to derive the auroral electrojet indices in the same way. We showed that monitoring the auroral electrojet is possible from magnetic field measurements at polar cap stations. For this purpose we used hourly values of geomagnetic field variations at four polar cap stations, distributed along polar cap boundary and occupying a longitudinal sector of about 14 hours, and calculated mean values of the total magnetic field disturbance T = (X2 + Y2 + Z2)1/2 where X, Y, and Z are geomagnetic field components measured at these polar cap stations. The set of the obtained values were called the T index. This index has a clear physical mining: it is the summary of geomagnetic disturbance in all three components averaged over the polar cap boundary. We found that correlation coefficients for the dependence of the T index on both AL and AE indices are as high as ~0.9 and higher. The high correlation of the T index with the AL and AE indices takes place for any UT hour when the stations were located at the night side. The T index further shows good correlation with solar wind parameters: the correlation coefficient for the dependence of the T index on the solar wind-geomagnetic activity coupling function is ~0.8 and higher, which is close to the correlation coefficient for AL index. The T index may be especially important in the cases when ground-based measurements in the auroral zone are impossible as in the southern hemisphere.
Chen, Lihua; Liu, Min; Bao, Jing; Xia, Yunbao; Zhang, Jiuquan; Zhang, Lin; Huang, Xuequan; Wang, Jian
2013-01-01
To perform a meta-analysis exploring the correlation between the apparent diffusion coefficient (ADC) and tumor cellularity in patients. We searched medical and scientific literature databases for studies discussing the correlation between the ADC and tumor cellularity in patients. Only studies that were published in English or Chinese prior to November 2012 were considered for inclusion. Summary correlation coefficient (r) values were extracted from each study, and 95% confidence intervals (CIs) were calculated. Sensitivity and subgroup analyses were performed to investigate potential heterogeneity. Of 189 studies, 28 were included in the meta-analysis, comprising 729 patients. The pooled r for all studies was -0.57 (95% CI: -0.62, -0.52), indicating notable heterogeneity (P<0.001). After the sensitivity analysis, two studies were excluded, and the pooled r was -0.61 (95% CI: -0.66, -0.56) and was not significantly heterogeneous (P = 0.127). Regarding tumor type subgroup analysis, there were sufficient data to support a strong negative correlation between the ADC and cellularity for brain tumors. There was no notable evidence of publication bias. There is a strong negative correlation between the ADC and tumor cellularity in patients, particularly in the brain. However, larger, prospective studies are warranted to validate these findings in other cancer types.
Genetic diversity of popcorn genotypes using molecular analysis.
Resh, F S; Scapim, C A; Mangolin, C A; Machado, M F P S; do Amaral, A T; Ramos, H C C; Vivas, M
2015-08-19
In this study, we analyzed dominant molecular markers to estimate the genetic divergence of 26 popcorn genotypes and evaluate whether using various dissimilarity coefficients with these dominant markers influences the results of cluster analysis. Fifteen random amplification of polymorphic DNA primers produced 157 amplified fragments, of which 65 were monomorphic and 92 were polymorphic. To calculate the genetic distances among the 26 genotypes, the complements of the Jaccard, Dice, and Rogers and Tanimoto similarity coefficients were used. A matrix of Dij values (dissimilarity matrix) was constructed, from which the genetic distances among genotypes were represented in a more simplified manner as a dendrogram generated using the unweighted pair-group method with arithmetic average. Clusters determined by molecular analysis generally did not group material from the same parental origin together. The largest genetic distance was between varieties 17 (UNB-2) and 18 (PA-091). In the identification of genotypes with the smallest genetic distance, the 3 coefficients showed no agreement. The 3 dissimilarity coefficients showed no major differences among their grouping patterns because agreement in determining the genotypes with large, medium, and small genetic distances was high. The largest genetic distances were observed for the Rogers and Tanimoto dissimilarity coefficient (0.74), followed by the Jaccard coefficient (0.65) and the Dice coefficient (0.48). The 3 coefficients showed similar estimations for the cophenetic correlation coefficient. Correlations among the matrices generated using the 3 coefficients were positive and had high magnitudes, reflecting strong agreement among the results obtained using the 3 evaluated dissimilarity coefficients.
Chirico, Nicola; Gramatica, Paola
2011-09-26
The main utility of QSAR models is their ability to predict activities/properties for new chemicals, and this external prediction ability is evaluated by means of various validation criteria. As a measure for such evaluation the OECD guidelines have proposed the predictive squared correlation coefficient Q(2)(F1) (Shi et al.). However, other validation criteria have been proposed by other authors: the Golbraikh-Tropsha method, r(2)(m) (Roy), Q(2)(F2) (Schüürmann et al.), Q(2)(F3) (Consonni et al.). In QSAR studies these measures are usually in accordance, though this is not always the case, thus doubts can arise when contradictory results are obtained. It is likely that none of the aforementioned criteria is the best in every situation, so a comparative study using simulated data sets is proposed here, using threshold values suggested by the proponents or those widely used in QSAR modeling. In addition, a different and simple external validation measure, the concordance correlation coefficient (CCC), is proposed and compared with other criteria. Huge data sets were used to study the general behavior of validation measures, and the concordance correlation coefficient was shown to be the most restrictive. On using simulated data sets of a more realistic size, it was found that CCC was broadly in agreement, about 96% of the time, with other validation measures in accepting models as predictive, and in almost all the examples it was the most precautionary. The proposed concordance correlation coefficient also works well on real data sets, where it seems to be more stable, and helps in making decisions when the validation measures are in conflict. Since it is conceptually simple, and given its stability and restrictiveness, we propose the concordance correlation coefficient as a complementary, or alternative, more prudent measure of a QSAR model to be externally predictive.
Chen, Ying; Cai, Xiaoyu; Jiang, Long; Li, Yu
2016-02-01
Based on the experimental data of octanol-air partition coefficients (KOA) for 19 polychlorinated biphenyl (PCB) congeners, two types of QSAR methods, comparative molecular field analysis (CoMFA) and comparative molecular similarity indices analysis (CoMSIA), are used to establish 3D-QSAR models using the structural parameters as independent variables and using logKOA values as the dependent variable with the Sybyl software to predict the KOA values of the remaining 190 PCB congeners. The whole data set (19 compounds) was divided into a training set (15 compounds) for model generation and a test set (4 compounds) for model validation. As a result, the cross-validation correlation coefficient (q(2)) obtained by the CoMFA and CoMSIA models (shuffled 12 times) was in the range of 0.825-0.969 (>0.5), the correlation coefficient (r(2)) obtained was in the range of 0.957-1.000 (>0.9), and the SEP (standard error of prediction) of test set was within the range of 0.070-0.617, indicating that the models were robust and predictive. Randomly selected from a set of models, CoMFA analysis revealed that the corresponding percentages of the variance explained by steric and electrostatic fields were 23.9% and 76.1%, respectively, while CoMSIA analysis by steric, electrostatic and hydrophobic fields were 0.6%, 92.6%, and 6.8%, respectively. The electrostatic field was determined as a primary factor governing the logKOA. The correlation analysis of the relationship between the number of Cl atoms and the average logKOA values of PCBs indicated that logKOA values gradually increased as the number of Cl atoms increased. Simultaneously, related studies on PCB detection in the Arctic and Antarctic areas revealed that higher logKOA values indicate a stronger PCB migration ability. From CoMFA and CoMSIA contour maps, logKOA decreased when substituents possessed electropositive groups at the 2-, 3-, 3'-, 5- and 6- positions, which could reduce the PCB migration ability. These results are expected to be beneficial in predicting logKOA values of PCB homologues and derivatives and in providing a theoretical foundation for further elucidation of the global migration behaviour of PCBs. Copyright © 2015 Elsevier Inc. All rights reserved.
Verifying the Dependence of Fractal Coefficients on Different Spatial Distributions
NASA Astrophysics Data System (ADS)
Gospodinov, Dragomir; Marekova, Elisaveta; Marinov, Alexander
2010-01-01
A fractal distribution requires that the number of objects larger than a specific size r has a power-law dependence on the size N(r) = C/rD∝r-D where D is the fractal dimension. Usually the correlation integral is calculated to estimate the correlation fractal dimension of epicentres. A `box-counting' procedure could also be applied giving the `capacity' fractal dimension. The fractal dimension can be an integer and then it is equivalent to a Euclidean dimension (it is zero of a point, one of a segment, of a square is two and of a cube is three). In general the fractal dimension is not an integer but a fractional dimension and there comes the origin of the term `fractal'. The use of a power-law to statistically describe a set of events or phenomena reveals the lack of a characteristic length scale, that is fractal objects are scale invariant. Scaling invariance and chaotic behavior constitute the base of a lot of natural hazards phenomena. Many studies of earthquakes reveal that their occurrence exhibits scale-invariant properties, so the fractal dimension can characterize them. It has first been confirmed that both aftershock rate decay in time and earthquake size distribution follow a power law. Recently many other earthquake distributions have been found to be scale-invariant. The spatial distribution of both regional seismicity and aftershocks show some fractal features. Earthquake spatial distributions are considered fractal, but indirectly. There are two possible models, which result in fractal earthquake distributions. The first model considers that a fractal distribution of faults leads to a fractal distribution of earthquakes, because each earthquake is characteristic of the fault on which it occurs. The second assumes that each fault has a fractal distribution of earthquakes. Observations strongly favour the first hypothesis. The fractal coefficients analysis provides some important advantages in examining earthquake spatial distribution, which are:—Simple way to quantify scale-invariant distributions of complex objects or phenomena by a small number of parameters.—It is becoming evident that the applicability of fractal distributions to geological problems could have a more fundamental basis. Chaotic behaviour could underlay the geotectonic processes and the applicable statistics could often be fractal. The application of fractal distribution analysis has, however, some specific aspects. It is usually difficult to present an adequate interpretation of the obtained values of fractal coefficients for earthquake epicenter or hypocenter distributions. That is why in this paper we aimed at other goals—to verify how a fractal coefficient depends on different spatial distributions. We simulated earthquake spatial data by generating randomly points first in a 3D space - cube, then in a parallelepiped, diminishing one of its sides. We then continued this procedure in 2D and 1D space. For each simulated data set we calculated the points' fractal coefficient (correlation fractal dimension of epicentres) and then checked for correlation between the coefficients values and the type of spatial distribution. In that way one can obtain a set of standard fractal coefficients' values for varying spatial distributions. These then can be used when real earthquake data is analyzed by comparing the real data coefficients values to the standard fractal coefficients. Such an approach can help in interpreting the fractal analysis results through different types of spatial distributions.
Li, Gui Dian; Liang, Ying Yin; Xu, Ping; Ling, Jian; Chen, Ying Ming
2016-04-01
The purpose of this study is to investigate the correlation of apparent diffusion coefficient (ADC) and fractional anisotropy (FA) values with fatty infiltration in the thigh muscles of patients with Duchenne muscular dystrophy (DMD) using diffusion-tensor imaging (DTI). Twenty-one boys with DMD were recruited. The grade of fatty infiltration and the ADC and FA values of four thigh muscles (rectus femoris, semitendinosus, sartorius, and gracilis) were measured, and the FA and ADC values were compared with the grade of fatty infiltration. Twenty age-matched healthy boys were enrolled as the control group. The differences in the ADC and FA values of the thigh muscles between patients with DMD and the control group were compared. The patients with DMD showed lower FA values and higher ADC values in all measured muscles when compared with the control group. The FA and ADC values were correlated with the grade of fatty infiltration. For the rectus femoris muscle, r = -0.753 and p = 0.007 for FA, and r = 0.685 and p = 0.001 for ADC. For the semitendinosus muscle, r = -0.621 and p = 0.041 for FA, and r = 0.705 and p = 0.021 for ADC. For the sartorius muscle, r = -0.662 and p = 0.027 for FA, and r = 0.701 and p = 0.017 for ADC. For the gracilis muscle, r = -0.618 and p = 0.043 for FA, and r = 0.695 and p = 0.022 for ADC. Damage to the thigh muscles in patients with DMD can be detected by ADC and FA values using DTI. DTI can be used to assess the severity of the disease.
NASA Astrophysics Data System (ADS)
Parviainen, Hannu
2015-10-01
PyLDTk automates the calculation of custom stellar limb darkening (LD) profiles and model-specific limb darkening coefficients (LDC) using the library of PHOENIX-generated specific intensity spectra by Husser et al. (2013). It facilitates exoplanet transit light curve modeling, especially transmission spectroscopy where the modeling is carried out for custom narrow passbands. PyLDTk construct model-specific priors on the limb darkening coefficients prior to the transit light curve modeling. It can also be directly integrated into the log posterior computation of any pre-existing transit modeling code with minimal modifications to constrain the LD model parameter space directly by the LD profile, allowing for the marginalization over the whole parameter space that can explain the profile without the need to approximate this constraint by a prior distribution. This is useful when using a high-order limb darkening model where the coefficients are often correlated, and the priors estimated from the tabulated values usually fail to include these correlations.
Klement, Aleš; Kodešová, Radka; Bauerová, Martina; Golovko, Oksana; Kočárek, Martin; Fér, Miroslav; Koba, Olga; Nikodem, Antonín; Grabic, Roman
2018-03-01
The sorption of 3 pharmaceuticals, which may exist in 4 different forms depending on the solution pH (irbesartan in cationic, neutral and anionic, fexofenadine in cationic, zwitter-ionic and anionic, and citalopram cationic and neutral), in seven different soils was studied. The measured sorption isotherms were described by Freundlich equations, and the sorption coefficients, K F (for the fixed n exponent for each compound), were related to the soil properties to derive relationships for estimating the sorption coefficients from the soil properties (i.e., pedotransfer rules). The largest sorption was obtained for citalopram (average K F value for n = 1 was 1838 cm 3 g -1 ) followed by fexofenadine (K F = 35.1 cm 3/n μg 1-1/n g -1 , n = 1.19) and irbesartan (K F = 3.96 cm 3/n μg 1-1/n g -1 , n = 1.10). The behavior of citalopram (CIT) in soils was different than the behaviors of irbesartan (IRB) and fexofenadine (FEX). Different trends were documented according to the correlation coefficients between the K F values for different compounds (R IRB,FEX = 0.895, p-value<0.01; R IRB,CIT = -0.835, p-value<0.05; R FEX,CIT = -0.759, p-value<0.05) and by the reverse relationships between the K F values and soil properties in the pedotransfer functions. While the K F value for citalopram was positively related to base cation saturation (BCS) or sorption complex saturation (SCS) and negatively correlated to the organic carbon content (Cox), the K F values of irbesartan and fexofenadine were negatively related to BCS, SCS or the clay content and positively related to Cox. The best estimates were obtained by combining BCS and Cox for citalopram (R 2 = 93.4), SCS and Cox for irbesartan (R 2 = 96.3), and clay content and Cox for fexofenadine (R 2 = 82.9). Copyright © 2017 Elsevier Ltd. All rights reserved.
Effect of Strain, Region, and Tissue Composition on Glucose Partitioning in Meniscus Fibrocartilage.
Kleinhans, Kelsey L; Jackson, Alicia R
2017-03-01
A nearly avascular tissue, the knee meniscus relies on diffusive transport for nutritional supply to cells. Nutrient transport depends on solute partitioning in the tissue, which governs the amount of nutrients that can enter a tissue. The purpose of the present study was to investigate the effects of mechanical strain, tissue region, and tissue composition on the partition coefficient of glucose in meniscus fibrocartilage. A simple partitioning experiment was employed to measure glucose partitioning in porcine meniscus tissues from two regions (horn and central), from both meniscal components (medial and lateral), and at three levels of compression (0%, 10%, and 20%). Partition coefficient values were correlated to strain level, water volume fraction, and glycosaminoglycan (GAG) content of tissue specimens. Partition coefficient values ranged from 0.47 to 0.91 (n = 48). Results show that glucose partition coefficient is significantly (p < 0.001) affected by compression, decreasing with increasing strain. Furthermore, we did not find a statistically significant effect of tissue when comparing medial versus lateral (p = 0.181) or when comparing central and horn regions (p = 0.837). There were significant positive correlations between tissue water volume fraction and glucose partitioning for all groups. However, the correlation between GAG content and partitioning was only significant in the lateral horn group. Determining how glucose partitioning is affected by tissue composition and loading is necessary for understanding nutrient availability and related tissue health and/or degeneration. Therefore, this study is important for better understanding the transport and nutrition-related mechanisms of meniscal degeneration.
Xu, Feng; Liang, Xinmiao; Lin, Bingcheng; Su, Fan; Schramm, Karl-Werner; Kettrup, Antonius
2002-08-01
The capacity factors of a series of hydrophobic organic compounds (HOCs) were measured in soil leaching column chromatography (SLCC) on a soil column, and in reversed-phase liquid chromatography on a C18 column with different volumetric fractions (phi) of methanol in methanol-water mixtures. A general equation of linear solvation energy relationships, log(XYZ) XYZ0 + mV(I)/100 + spi + bbetam + aalpham, was applied to analyze capacity factors (k'), soil organic partition coefficients (Koc) and octanol-water partition coefficients (P). The analyses exhibited high accuracy. The chief solute factors that control logKoc, log P, and logk' (on soil and on C18) are the solute size (V(I)/100) and hydrogen-bond basicity (betam). Less important solute factors are the dipolarity/polarizability (pi*) and hydrogen-bond acidity (alpham). Log k' on soil and log Koc have similar signs in four fitting coefficients (m, s, b and a) and similar ratios (m:s:b:a), while log k' on C18 and logP have similar signs in coefficients (m, s, b and a) and similar ratios (m:s:b:a). Consequently, logk' values on C18 have good correlations with logP (r > 0.97), while logk' values on soil have good correlations with logKoc (r > 0.98). Two Koc estimation methods were developed, one through solute solvatochromic parameters, and the other through correlations with k' on soil. For HOCs, a linear relationship between logarithmic capacity factor and methanol composition in methanol-water mixtures could also be derived in SLCC.
Reproducibility of intraocular pressure peak and fluctuation of the water-drinking test.
Hatanaka, Marcelo; Alencar, Luciana M; De Moraes, Carlos G; Susanna, Remo
2013-01-01
The water-drinking test has been used as a stress test to evaluate the drainage system of the eye. However, in order to be clinically applicable,a test must provide reproducible results with consistent measurements. This study was performed to verify the reproducibility of intraocular pressure peaks and fluctuation detected during the water-drinking test in patients with ocular hypertension and open-angle glaucoma. A prospective analysis of patients in a tertiary care unit for glaucoma treatment. Twenty-four ocular hypertension and 64 open-angle glaucoma patients not under treatment. The water-drinking test was performed in 2 consecutive days by the same examiners in patients not under treatment. Reproducibility was assessed using the intraclass correlation coefficient. Peak and fluctuation of intraocular pressure obtained with the water-drinking test were analysed for reproducibility. Eighty-eight eyes from 24 ocular hypertension and 64 open-angle glaucoma patients not under treatment were evaluated. Test and retest intraocular pressure peak values were 28.38 ± 4.64 and 28.38 ± 4.56 mmHg, respectively (P = 1.00). Test and retest intraocular pressure fluctuation values were 5.75 ± 3.9 and 4.99 ± 2.7 mmHg, respectively (P = 0.06). Based on intraclass coefficient, reproducibility was excellent for peak intraocular pressure (intraclass correlation coefficient = 0.79) and fair for intraocular pressure fluctuation (intraclass correlation coefficient = 0.37). Intraocular pressure peaks detected during the water-drinking test presented excellent reproducibility, whereas the reproducibility of fluctuation was considered fair. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.
Reischauer, Carolin; Patzwahl, René; Koh, Dow-Mu; Froehlich, Johannes M; Gutzeit, Andreas
2018-04-01
To evaluate whole-lesion volumetric texture analysis of apparent diffusion coefficient (ADC) maps for assessing treatment response in prostate cancer bone metastases. Texture analysis is performed in 12 treatment-naïve patients with 34 metastases before treatment and at one, two, and three months after the initiation of androgen deprivation therapy. Four first-order and 19 second-order statistical texture features are computed on the ADC maps in each lesion at every time point. Repeatability, inter-patient variability, and changes in the feature values under therapy are investigated. Spearman rank's correlation coefficients are calculated across time to demonstrate the relationship between the texture features and the serum prostate specific antigen (PSA) levels. With few exceptions, the texture features exhibited moderate to high precision. At the same time, Friedman's tests revealed that all first-order and second-order statistical texture features changed significantly in response to therapy. Thereby, the majority of texture features showed significant changes in their values at all post-treatment time points relative to baseline. Bivariate analysis detected significant correlations between the great majority of texture features and the serum PSA levels. Thereby, three first-order and six second-order statistical features showed strong correlations with the serum PSA levels across time. The findings in the present work indicate that whole-tumor volumetric texture analysis may be utilized for response assessment in prostate cancer bone metastases. The approach may be used as a complementary measure for treatment monitoring in conjunction with averaged ADC values. Copyright © 2018 Elsevier B.V. All rights reserved.
Selling blood and gametes during tough economic times: insights from Google search.
Wu, Jonathan A; Ngo, Tin C; Rothman, Cappy; Breyer, Benjamin N; Eisenberg, Michael L
2015-10-01
To use Google Insights search volume and publicly available economic indicators to test the hypothesis that sperm, egg, and blood donations increase during economic downturns and to demonstrate the feasibility of using Google search volume data to predict national trends in actual sperm, egg, and blood donations rates. Cross-correlation statistical analysis comparing Google search data for terms relating to blood, egg, and sperm donations with various economic indicators including the S&P 500 closing values, gross domestic product (GDP), the U.S. Index of Leading Indicators (U.S. Leading Index), gross savings rate, mortgage interest rates, unemployment rate, and consumer price index (CPI) from 2004-2011. A secondary analysis determined the Pearson correlation coefficient between Google search data with actual sperm, egg, and blood donation volume in the U.S. as measured by California Cryobank, the National Assisted Reproductive Technology Surveillance System, and the National Blood Collection and Utilization Survey, respectively. Significance of cross-correlation and Pearson correlation analysis as indicated by p value. There were several highly significant cross-correlation relationships between search volume and various economic indicators. Correlation between Google search volume for the term 'sperm donation,' 'egg donation,' and 'blood donation' with actual number of sperm, egg and blood donations in the United States demonstrated Pearson correlation coefficients of 0.2 (p > 0.10), -0.1 (p > 0.10), and 0.07 (p > 0.10), respectively. Temporal analysis showed an improved correlation coefficient of 0.9 (p < 0.05) for blood donation when shifted 12 months later relative to Google search volume. Google search volume data for search terms relating to sperm, egg, and blood donation increase during economic downturns. This finding suggests gamete and bodily fluid donations are influenced by market forces like other commodities. Google search may be useful for predicting blood donation trends but is more limited in predicting actual semen and oocyte donation patterns.
Edjabou, Maklawe Essonanawe; Martín-Fernández, Josep Antoni; Scheutz, Charlotte; Astrup, Thomas Fruergaard
2017-11-01
Data for fractional solid waste composition provide relative magnitudes of individual waste fractions, the percentages of which always sum to 100, thereby connecting them intrinsically. Due to this sum constraint, waste composition data represent closed data, and their interpretation and analysis require statistical methods, other than classical statistics that are suitable only for non-constrained data such as absolute values. However, the closed characteristics of waste composition data are often ignored when analysed. The results of this study showed, for example, that unavoidable animal-derived food waste amounted to 2.21±3.12% with a confidence interval of (-4.03; 8.45), which highlights the problem of the biased negative proportions. A Pearson's correlation test, applied to waste fraction generation (kg mass), indicated a positive correlation between avoidable vegetable food waste and plastic packaging. However, correlation tests applied to waste fraction compositions (percentage values) showed a negative association in this regard, thus demonstrating that statistical analyses applied to compositional waste fraction data, without addressing the closed characteristics of these data, have the potential to generate spurious or misleading results. Therefore, ¨compositional data should be transformed adequately prior to any statistical analysis, such as computing mean, standard deviation and correlation coefficients. Copyright © 2017 Elsevier Ltd. All rights reserved.
[Validation of the German version of the Oxford Elbow Score : A cross-sectional study].
Marquardt, J; Schöttker-Königer, T; Schäfer, A
2016-08-01
Elbow complaints are complex problems leading to severe consequences for affected people and the healthcare system. The German version of the Oxford Elbow Score (OES) is the first German-speaking instrument that specifically measures elbow complaints from the patient's perspective and changes of their health status. The aim of this study is the validation of the German version of the OES. In this context the internal consistency and the construct validity were investigated. 59 patients with elbow complaints completed the German version of the OES, the DASH and the SF-36 in a cross-sectional study. The internal consistency was calculated with Cronbach's alpha coefficients. Spearman's correlation coefficients were used to confirm construct validity. Cronbach's alpha for pain, function and psychological subscales was 0.88, 0.81 and 0.90, respectively. The whole questionnaire presents a Cronbach's alpha value of 0.93. Convergent construct validity was confirmed with correlation coefficients containing values of -0.84, -0.77 and -0.82 compared to DASH and values ranging from 0.41 to 0.80 compared with the physical domains of the SF-36. The divergent construct validity presented values ranging from 0.07 to 0.20 with the SF-36 domains of "general health perception" and "mental health". The German OES is an internal consistent instrument with good convergent and divergent construct validity. Other aspects of the validity, the reliability and the responsiveness should be confirmed through further studies.
Measurement of diffusion coefficients from solution rates of bubbles
NASA Technical Reports Server (NTRS)
Krieger, I. M.
1979-01-01
The rate of solution of a stationary bubble is limited by the diffusion of dissolved gas molecules away from the bubble surface. Diffusion coefficients computed from measured rates of solution give mean values higher than accepted literature values, with standard errors as high as 10% for a single observation. Better accuracy is achieved with sparingly soluble gases, small bubbles, and highly viscous liquids. Accuracy correlates with the Grashof number, indicating that free convection is the major source of error. Accuracy should, therefore, be greatly increased in a gravity-free environment. The fact that the bubble will need no support is an additional important advantage of Spacelab for this measurement.
Predicting the Performance of Chain Saw Machines Based on Shore Scleroscope Hardness
NASA Astrophysics Data System (ADS)
Tumac, Deniz
2014-03-01
Shore hardness has been used to estimate several physical and mechanical properties of rocks over the last few decades. However, the number of researches correlating Shore hardness with rock cutting performance is quite limited. Also, rather limited researches have been carried out on predicting the performance of chain saw machines. This study differs from the previous investigations in the way that Shore hardness values (SH1, SH2, and deformation coefficient) are used to determine the field performance of chain saw machines. The measured Shore hardness values are correlated with the physical and mechanical properties of natural stone samples, cutting parameters (normal force, cutting force, and specific energy) obtained from linear cutting tests in unrelieved cutting mode, and areal net cutting rate of chain saw machines. Two empirical models developed previously are improved for the prediction of the areal net cutting rate of chain saw machines. The first model is based on a revised chain saw penetration index, which uses SH1, machine weight, and useful arm cutting depth as predictors. The second model is based on the power consumed for only cutting the stone, arm thickness, and specific energy as a function of the deformation coefficient. While cutting force has a strong relationship with Shore hardness values, the normal force has a weak or moderate correlation. Uniaxial compressive strength, Cerchar abrasivity index, and density can also be predicted by Shore hardness values.
Benhaim, Deborah; Grushka, Eli
2008-10-31
In this study, we show that the addition of n-octanol to the mobile phase improves the chromatographic determination of lipophilicity parameters of xenobiotics (neutral solutes, acidic, neutral and basic drugs) on a Phenomenex Gemini C18 column. The Gemini C18 column is a new generation hybrid silica-based column with an extended pH range capability. The wide pH range (2-12) afforded the examination of basic drugs and acidic drugs in their neutral form. Extrapolated retention factor values, [Formula: see text] , obtained on the above column with the n-octanol-modified mobile phase were very well correlated (1:1 correlation) with literature values of logP (logarithm of the partition coefficient in n-octanol/water) of neutral compounds and neutral drugs (69). In addition, we found good linear correlations between measured [Formula: see text] values and calculated values of the logarithm of the distribution coefficient at pH 7.0 (logD(7.0)) for ionized acidic and basic drugs (r(2)=0.95). The Gemini C18 phase was characterized using the linear solvation energy relationship (LSER) model of Abraham. The LSER system constants for the column were compared to the LSER constants of n-octanol/water extraction system using the Tanaka radar plots. The comparison shows that the two methods are nearly equivalent.
Sensitivity Analysis of the Integrated Medical Model for ISS Programs
NASA Technical Reports Server (NTRS)
Goodenow, D. A.; Myers, J. G.; Arellano, J.; Boley, L.; Garcia, Y.; Saile, L.; Walton, M.; Kerstman, E.; Reyes, D.; Young, M.
2016-01-01
Sensitivity analysis estimates the relative contribution of the uncertainty in input values to the uncertainty of model outputs. Partial Rank Correlation Coefficient (PRCC) and Standardized Rank Regression Coefficient (SRRC) are methods of conducting sensitivity analysis on nonlinear simulation models like the Integrated Medical Model (IMM). The PRCC method estimates the sensitivity using partial correlation of the ranks of the generated input values to each generated output value. The partial part is so named because adjustments are made for the linear effects of all the other input values in the calculation of correlation between a particular input and each output. In SRRC, standardized regression-based coefficients measure the sensitivity of each input, adjusted for all the other inputs, on each output. Because the relative ranking of each of the inputs and outputs is used, as opposed to the values themselves, both methods accommodate the nonlinear relationship of the underlying model. As part of the IMM v4.0 validation study, simulations are available that predict 33 person-missions on ISS and 111 person-missions on STS. These simulated data predictions feed the sensitivity analysis procedures. The inputs to the sensitivity procedures include the number occurrences of each of the one hundred IMM medical conditions generated over the simulations and the associated IMM outputs: total quality time lost (QTL), number of evacuations (EVAC), and number of loss of crew lives (LOCL). The IMM team will report the results of using PRCC and SRRC on IMM v4.0 predictions of the ISS and STS missions created as part of the external validation study. Tornado plots will assist in the visualization of the condition-related input sensitivities to each of the main outcomes. The outcomes of this sensitivity analysis will drive review focus by identifying conditions where changes in uncertainty could drive changes in overall model output uncertainty. These efforts are an integral part of the overall verification, validation, and credibility review of IMM v4.0.
Nazhan, Salam; Ghassemlooy, Zabih; Busawon, Krishna
2016-01-01
In this paper, the influence of the rotating polarization-preserved optical feedback on the chaos synchronization of a vertical-cavity surface-emitting laser (VCSEL) is investigated experimentally. Two VCSELs' polarization modes (XP) and (YP) are gradually rotated and re-injected back into the VCSEL. The anti-phase dynamics synchronization of the two polarization modes is evaluated using the cross-correlation function. For a fixed optical feedback, a clear relationship is found between the cross-correlation coefficient and the polarization angle θp. It is shown that high-quality anti-phase polarization-resolved chaos synchronization is achieved at higher values of θp. The maximum value of the cross-correlation coefficient achieved is -0.99 with a zero time delay over a wide range of θp beyond 65° with a poor synchronization dynamic at θp less than 65°. Furthermore, it is observed that the antiphase irregular oscillation of the XP and YP modes changes with θp. VCSEL under the rotating polarization optical feedback can be a good candidate as a chaotic synchronization source for a secure communication system.
Turkish version of the Academic Motivation Scale.
Can, Gürhan
2015-04-01
The purpose of this study was to adapt the college version of the Academic Motivation Scale (AMS) into Turkish. The participants were 797 college students (437 men, 360 women) with a mean age of 20.1 yr. A seven-factor model of the scale, as well as alternative models (five-, three-, two-, and one-factor models) were investigated and compared through confirmatory factor analysis. The seven-factor model demonstrated adequate fit to the data. The fit indices obtained from the five-factor model were acceptable also. Hancock's coefficient H values and test-retest correlation coefficients of the subscales indicated that reliability of the scale was adequate except for the identified regulation subscale. The CFA conducted for the groups of men and women produced more acceptable fit indices values for men than women, but women obtained significantly higher scores from the AMS subscales. Correlations among the seven subscales partially supported the simplex pattern which claims that the neighboring subscales should have stronger positive correlations than the non-neighboring subscales and that the subscales which are the farthest apart should have the strongest negative relationships.
[Study on the indexes of forensic identification by the occlusal-facial digital radiology].
Gao, Dong; Wang, Hu; Hu, Jin-liang; Xu, Zhe; Deng, Zhen-hua
2006-02-01
To discuss the coding of full dentition with 32 locations and measure the characteristics of some bony indexes in occlusal-facial digital radiology (DR). To select randomly three hundred DR orthopantomogram and code the full dentition, then analyze the diversity of dental patterns. To select randomly one hundred DR lateral cephalogram and measure six indexes (N-S,N-Me,Cd-Gn,Cd-Go,NP-SN,MP-SN) separately by one odontologist and one trained forensic graduate student, then calculate the coefficient variation (CV) of every index and take a correlation analysis for the consistency between two measurements. (1) The total diversity of 300 dental patterns was 75%.It was a very high value. (2)All six quantitative variables had comparatively high CV value.(3) After the linear correlation analysis between two measurements, all six coefficient correlations were close to 1. This indicated that the measurements were stable and consistent. The method of coding full dentition in DR orthopantomogram and measuring six bony indexes in DR lateral cephalogram can be used to forensic identification.
Integral Equation Study of Molecular Fluids and Liquid Crystals in Two Dimensions
NASA Astrophysics Data System (ADS)
Ward, David Atlee
The Ornstein-Zernike (OZ) equation is solved with a Percus-Yevick (PY) closure for the hard ellipse and hard planar dumbell fluids in two dimensions. The correlation functions, including the orientation correlation function, are expanded in a set of orthogonal functions and the coefficients are solved for using an iterative algorithm developed by Lado. The pressure, compressibility, and orientation coefficients are computed for a variety of densities and molecular elongations. The hard planar dumbell fluid shows no orientational ordering. The PY values for the pressure differ from the corresponding Monte Carlo (MC) values by as much as 8% for the cases studied. The hard ellipse fluid exhibits some orientational ordering. Ordering is much more pronounced for ellipses with an axis ratio larger than 2.0. Pressure values computed for the hard ellipse fluid from the PY theory differ from the corresponding MC values by as much as 11% for the cases studied. As the PY solutions do exhibit a nematic character in the hard ellipse fluid, we find it to be a viable reference system for further studies of the nematic liquid crystal phase, though the isotropic-nematic (I-N) phase transition found by Vieillard-Baron was not observed in the PY solutions. The Maier-Saupe theory was reformulated based on the density functional formalism of Sluckin and Shukla. Using PY data of the hard ellipse as input for the direct correlation function in the isotropic phase, the orientational distribution was calculated. The values obtained showed only extremely weak nematic behavior.
Bhadra, S.; Hertzberg, B. J.; Croft, M.; ...
2015-03-13
The coefficient of restitution of alkaline batteries had been shown to increase as a function of depth of discharge. In this work, using non-destructive mechanical testing, the change in coefficient of restitution is compared to in situ energy-dispersive x-ray diffraction data to determine the cause of the macroscopic change in coefficient of restitution. The increase in coefficient of restitution correlates to the formation of a percolation pathway of ZnO within the anode of the cell, and that the coefficient of restitution saturates at a value of 0.63 ± .05 at 50% state if charge when the anode has densified intomore » porous ZnO solid. Of note is the sensitivity of coefficient of restitution to the amount of ZnO formation that rivals the sensitivity on in situ energy-dispersive x-ray diffraction spectroscopy.« less
Comparing the structure of an emerging market with a mature one under global perturbation
NASA Astrophysics Data System (ADS)
Namaki, A.; Jafari, G. R.; Raei, R.
2011-09-01
In this paper we investigate the Tehran stock exchange (TSE) and Dow Jones Industrial Average (DJIA) in terms of perturbed correlation matrices. To perturb a stock market, there are two methods, namely local and global perturbation. In the local method, we replace a correlation coefficient of the cross-correlation matrix with one calculated from two Gaussian-distributed time series, whereas in the global method, we reconstruct the correlation matrix after replacing the original return series with Gaussian-distributed time series. The local perturbation is just a technical study. We analyze these markets through two statistical approaches, random matrix theory (RMT) and the correlation coefficient distribution. By using RMT, we find that the largest eigenvalue is an influence that is common to all stocks and this eigenvalue has a peak during financial shocks. We find there are a few correlated stocks that make the essential robustness of the stock market but we see that by replacing these return time series with Gaussian-distributed time series, the mean values of correlation coefficients, the largest eigenvalues of the stock markets and the fraction of eigenvalues that deviate from the RMT prediction fall sharply in both markets. By comparing these two markets, we can see that the DJIA is more sensitive to global perturbations. These findings are crucial for risk management and portfolio selection.
Belteki, Gusztav; Lin, Benjamin; Morley, Colin J
2017-10-01
Carbon-dioxide elimination during high-frequency oscillatory ventilation (HFOV) is thought to be proportional to the carbon dioxide diffusion coefficient (DCO 2 ) which is calculated as frequency x (tidal volume) 2 . DCO 2 can be used to as an indicator of CO 2 elimination but values obtained in different patients cannot be directly compared. To analyze the relationship between DCO 2 , the weight-corrected DCO 2 (DCO 2 corr) and blood gas PCO 2 values obtained from infants receiving HFOV. DCO 2 data were obtained from 14 infants at 1/s sampling rate and the mean DCO 2 was determined over 10 min periods preceding the time of the blood gas. DCO 2 corr was calculated by dividing the DCO 2 by the square of the body weight in kg. Weight-correction significantly reduced the inter-individual variability of DCO 2 . When data from all the babies were combined, standard DCO 2 showed no correlation with PCO 2 but DCO 2 corr showed a weak but statistically significant inverse correlation. The correlation was better when the endotracheal leak was <10%. There was significant inverse but weaker correlation between the HFOV tidal volume (VThf) and the PCO 2 . In any baby, DCO 2 corr >50 mL 2 /sec/kg 2 or VThf > 2.5 mL/kg was rarely needed to avoid hypercapnia. Weight-correction of DCO 2 values improved its comparability between patients. Weight-corrected DCO 2 correlated better with PCO 2 than uncorrected DCO 2 but the correlation was weak. © 2017 Wiley Periodicals, Inc.
Anderson, Stephan W; Soto, Jorge A; Milch, Holly N; Ozonoff, Al; O'Brien, Michael; Hamilton, James A; Jara, Hernan J
2011-04-01
To evaluate the apparent diffusion coefficient (ADC) values of liver in a murine model of non-alcoholic steatohepatitis using 11.7 Tesla (T) MRI. This animal study was IACUC approved. Seventeen male C57BL/6 mice were divided into control (n = 3) and experimental groups (n = 14) fed a methionine-deficient choline-deficient (MCD) diet to induce steatohepatitis. Livers underwent ex vivo diffusion-weighted MR imaging and ADC maps were calculated. A pathologist determined subjective scores of steatosis, classified from 0 to 3. Digital image analysis was used to determine percentage areas of steatosis. Graphs comparing ADC to subjective and digital image analysis (DIA) determinations of steatosis were plotted. Subjective assessments of steatosis ranged up to values of 3 and DIA determined areas of steatosis to range up to approximately 16%. ADC values approximated 800 × 10(-6) mm(2) /s (range, 749-811 × 10(-6) mm(2) /s, mean 786 × 10(-6) mm(2) /s) in controls and 500 × 10(-6) mm(2) /s (range, 478-733 × 10(-6) mm(2) /s, mean 625 × 10(-6) mm(2) /s) in experimental mice. Moderate correlation between ADC and subjective scores of steatosis (R = -0.56) was observed. Strong correlation between ADC values and percentage areas of steatosis was between ADC values and percentage areas of steatosis was observed greater (R = -0.81) and very strong correlation was observed with the exclusion of a single outlying data point (R = -0.91). Based on the comparison of ADC values and steatosis determinations by DIA, increasing degrees of steatosis are seen to result in decreased hepatic ADC values. Copyright © 2011 Wiley-Liss, Inc.
Wang, Yu; Zhang, Heng; Zhang, Ruzhi; Zhao, Zhoushe; Xu, Ziqian; Wang, Lei; Liu, Rongbo; Gao, Fabao
2017-01-01
To assess kidney damage in a rat model of type-2 diabetic nephropathy based on apparent diffusion coefficient (ADC) data obtained from ultra-high b-values and discuss its relationship to the expression of aquaporins (AQPs). This study was approved by the institutional Animal Care and Use Committee. Thirty male Sprague-Dawley rats were randomised into two groups: (1) untreated controls and (2) diabetes mellitus (DM). All rats underwent diffusion-weighted imaging (DWI) with 18 b-values (0-4500 s/mm 2 ). Maps of low ADC (ADC low ), standard ADC (ADC st ) and ultra-high ADC (ADC uh ) were calculated from low b-values (0-200 s/mm 2 ), standard b-values (300-1500 s/mm 2 ) and ultra-high b-values (1700-4500 s/mm 2 ), respectively. The expression of AQPs in the kidneys was studied using immunohistochemistry. Laboratory parameters of diabetic and kidney functions, ADC low , ADC st , ADC uh , and the optical density (OD) of AQP expression in the two groups were compared using an independent t test. Correlations between ADCs and the OD of AQP expression were evaluated by Pearson's correlation analysis. ADC uh were significantly higher in the cortex (CO), outer stripe of the outer medulla (OS) and inner stripe of the outer medulla (IS), and the OD values of AQ-2 were significantly higher in the OS, IS and inner medulla (IM) in DM animals compared with control animals. ADC uh and OD values of AQP-2 expression were positively correlated in the OS, IS and IM of the kidney. ADC uh may work as useful metrics for early detection of kidney damage in diabetic nephropathy and may be associated with AQP-2 expression.
Zhukov, V A; Kokorev, S V; Rogozhkina, S V; Melnikov, D G; Terentiev, A I; Kovalchuk, E A; Vakhnov, E Yu; Borisevich, S V
2016-01-01
Determination of values of coefficients of thermal stability of TEOVac for prognosis of conservation of the vaccine (specific biological activity) during the process of warranty period storage. TEOVac (masticatory tablets) in primary packaging was kept at increased temperature (accelerated and stress-tests) and at the conditions established by PAP for the preparation (long-term tests). Biological activity of the vaccine was determined by titration on 12-day chicken embryos. A correlation between the value of coefficients of thermal stability and conservation of the prepared series of the condition preparation at the final date of storage was experimentally established. Coefficients of thermal stability could be used as a prognostic indicator of quality of the produced pelleted formulation of the preparation for evaluation of conservation of the vaccine during warranty period storage.
Iijima, Ayaka; Shimizu, Kimiya; Yamagishi, Mayumi; Kobashi, Hidenaga; Igarashi, Akihito; Kamiya, Kazutaka
2016-12-01
To evaluate the subjective intraocular forward scattering and quality of vision after posterior chamber phakic intraocular lens with a central hole (Hole ICL, STAAR Surgical) implantation. We prospectively examined 29 eyes of 29 consecutive patients (15 men and 14 women; ages, 37.2 ± 8.8 years) undergoing Hole ICL implantation. We assessed the values of the logarithmic straylight value [log (s)] using a straylight meter (C-Quant ™ , Oculus) preoperatively and 3 months postoperatively. The patients completed a questionnaire detailing symptoms on a quantitative grading scale (National Eye Institute Refractive Error Quality of Life Instrument-42; NEI RQL-42) 3 months postoperatively. We compared the preoperative and postoperative values of the log(s) and evaluated the correlation of these values with patient subjective symptoms. The mean log(s) was not significantly changed, from 1.07 ± 0.20 preoperatively, to 1.06 ± 0.17 postoperatively (Wilcoxon signed-rank test, p = 0.641). There was a significant correlation between the preoperative and postoperative log(s) (Spearman's correlation coefficient r = 0.695, p < 0.001). The postoperative log(s) was significantly associated with the scores of glare in the questionnaire (Spearman's correlation coefficient r = -0.575, p = 0.017). According to our experience, Hole ICL implantation does not induce a significant additional change in the subjective intraocular forward scattering. The symptom of glare after Hole ICL implantation was significantly correlated with the postoperative intraocular forward scattering in relation to the preoperative one. © 2016 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Cho, Jae Hyung; Selen, Mats A; Kocheril, Abraham G
2015-08-11
The 12-lead electrocardiographic screening for the prevention of sudden cardiac death in young competitive athletes is not cost-effective and thus not routinely recommended. We investigate whether a less expensive wireless electrocardiographic transmission device can be used to screen for the prevention of sudden cardiac death in this population. During pre-participation screening, twenty college football players underwent two electrocardiograms: a conventional 12-lead electrocardiogram and a wireless 9-lead electrocardiogram. We compared several electrocardiographic parameters (QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria, ST deviation and corrected QT interval) to determine the correlation. The QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria and corrected QT interval exhibited significant correlation between the two types of electrocardiograms (correlation coefficient 0.878, 0.630, 0.770 and 0.847, respectively with P values of 0.01, 0.003, 0.01 and 0.01, respectively). ST deviation in V1 was weakly correlated between the two types of electrocardiograms without statistical significance (correlation coefficient 0.360 with a P value of 0.119). Our newly developed wireless 9-lead electrocardiogram demonstrated significant correlations with a conventional 12-lead electrocardiogram in terms of QRS duration, left ventricular hypertrophy and corrected QT interval.
Rounds, S.A.; Tiffany, B.A.; Pankow, J.F.
1993-01-01
Aerosol particles from a highway tunnel were collected on a Teflon membrane filter (TMF) using standard techniques. Sorbed organic compounds were then desorbed for 28 days by passing clean nitrogen through the filter. Volatile n-alkanes and polycyclic aromatic hydrocarbons (PAHs) were liberated from the filter quickly; only a small fraction of the less volatile ra-alkanes and PAHs were desorbed. A nonlinear least-squares method was used to fit an intraparticle diffusion model to the experimental data. Two fitting parameters were used: the gas/particle partition coefficient (Kp and an effective intraparticle diffusion coefficient (Oeff). Optimized values of Kp are in agreement with previously reported values. The slope of a correlation between the fitted values of Deff and Kp agrees well with theory, but the absolute values of Deff are a factor of ???106 smaller than predicted for sorption-retarded, gaseous diffusion. Slow transport through an organic or solid phase within the particles or preferential flow through the bed of particulate matter on the filter might be the cause of these very small effective diffusion coefficients. ?? 1993 American Chemical Society.
The feasibility of ranking material fracture toughness by ultrasonic attenuation measurements
NASA Technical Reports Server (NTRS)
Vary, A.
1975-01-01
A preliminary study was conducted to assess the feasibility of ultrasonically ranking material fracture toughness. Specimens of two grades of maraging steel for which fracture toughness values were measured were subjected to ultrasonic probing. The slope of the attenuation coefficient vs frequency curve was empirically correlated with the plane strain fracture toughness value for each grade of steel.
The feasibility of ranking material fracture toughness by ultrasonic attenuation measurements
NASA Technical Reports Server (NTRS)
Vary, A.
1975-01-01
A preliminary study was conducted to assess the feasibility of ultrasonically ranking material fracture toughness. Specimens of two grades of maraging steel for which fracture toughness values were measured were subjected to ultrasonic probing. The slope of the attenuation coefficient versus frequency curve was empirically correlated with the plane strain fracture toughness value for each grade of steel.
Retrieving atmospheric transmissivity for biologically active daily dose, in various european sites
NASA Astrophysics Data System (ADS)
de La Casinière, A.; Touré, M. L.; Lenoble, J.; Cabot, T.
2003-04-01
In the frame of the European Project EDUCE, global UV irradiance spectra recorded all along the year in several European sites are stored in a common database located in Finland. From the spectra set of some of these stations, are calculated atmospheric transmissivities for daily doses of four biologically active UV radiation, namely: UV-B, erythema, DNA damage, and plant damage. A transmissivity is defined as the ratio of the ground level value of the daily dose of interest to its corresponding extra-atmospheric value. Multiple linear correlation of the various transmissivities with three predictors (daily sunshine fraction, cosine of the daily minimum SZA, and daily total ozone column) assumed to be independent variables, are done for year 2000. The coefficients obtained from year 2000 correlation in a given site are expected to retrieve, from the local predictors, the daily dose for year 2001 in the same site, the average error being lesser than 10% for monthly mean values, and lesser than 5% for three-monthly mean values, depending on the daily dose type. Comparison of yearly mean daily doses retrieved in a given site from coefficients obtained in other sites is also presented.
Identifying Bearing Rotordynamic Coefficients using an Extended Kalman Filter
NASA Technical Reports Server (NTRS)
Miller, Brad A.; Howard, Samuel A.
2008-01-01
An Extended Kalman Filter is developed to estimate the linearized direct and indirect stiffness and damping force coefficients for bearings in rotor-dynamic applications from noisy measurements of the shaft displacement in response to imbalance and impact excitation. The bearing properties are modeled as stochastic random variables using a Gauss-Markov model. Noise terms are introduced into the system model to account for all of the estimation error, including modeling errors and uncertainties and the propagation of measurement errors into the parameter estimates. The system model contains two user-defined parameters that can be tuned to improve the filter s performance; these parameters correspond to the covariance of the system and measurement noise variables. The filter is also strongly influenced by the initial values of the states and the error covariance matrix. The filter is demonstrated using numerically simulated data for a rotor-bearing system with two identical bearings, which reduces the number of unknown linear dynamic coefficients to eight. The filter estimates for the direct damping coefficients and all four stiffness coefficients correlated well with actual values, whereas the estimates for the cross-coupled damping coefficients were the least accurate.
Price-volume multifractal analysis of the Moroccan stock market
NASA Astrophysics Data System (ADS)
El Alaoui, Marwane
2017-11-01
In this paper, we analyzed price-volume multifractal cross-correlations of Moroccan Stock Exchange. We chose the period from January 1st 2000 to January 20th 2017 to investigate the multifractal behavior of price change and volume change series. Then, we used multifractal detrended cross-correlations analysis method (MF-DCCA) and multifractal detrended fluctuation analysis (MF-DFA) to analyze the series. We computed bivariate generalized Hurst exponent, Rényi exponent and spectrum of singularity for each pair of indices to measure quantitatively cross-correlations. Furthermore, we used detrended cross-correlations coefficient (DCCA) and cross-correlation test (Q(m)) to analyze cross-correlation quantitatively and qualitatively. By analyzing results, we found existence of price-volume multifractal cross-correlations. The spectrum width has a strong multifractal cross-correlation. We remarked that volume change series is anti-persistent when we analyzed the generalized Hurst exponent for all moments q. The cross-correlation test showed the presence of a significant cross-correlation. However, DCCA coefficient had a small positive value, which means that the level of correlation is not very significant. Finally, we analyzed sources of multifractality and their degree of contribution in the series.
Interaction of finger enslaving and error compensation in multiple finger force production.
Martin, Joel R; Latash, Mark L; Zatsiorsky, Vladimir M
2009-01-01
Previous studies have documented two patterns of finger interaction during multi-finger pressing tasks, enslaving and error compensation, which do not agree with each other. Enslaving is characterized by positive correlation between instructed (master) and non-instructed (slave) finger(s) while error compensation can be described as a pattern of negative correlation between master and slave fingers. We hypothesize that pattern of finger interaction, enslaving or compensation depends on the initial force level and the magnitude of the targeted force change. Subjects were instructed to press with four fingers (I index, M middle, R ring, and L little) from a specified initial force to target forces following a ramp target line. Force-force relations between master and each of three slave fingers were analyzed during the ramp phase of trials by calculating correlation coefficients within each master-slave pair and then two-factor ANOVA was performed to determine effect of initial force and force increase on the correlation coefficients. It was found that, as initial force increased, the value of the correlation coefficient decreased and in some cases became negative, i.e. the enslaving transformed into error compensation. Force increase magnitude had a smaller effect on the correlation coefficients. The observations support the hypothesis that the pattern of inter-finger interaction--enslaving or compensation--depends on the initial force level and, to a smaller degree, on the targeted magnitude of the force increase. They suggest that the controller views tasks with higher steady-state forces and smaller force changes as implying a requirement to avoid large changes in the total force.
Schneider, Antonius; Szecsenyi, Joachim; Barie, Stefan; Joest, Katharina; Rosemann, Thomas
2007-01-01
Background The aim of the study was to examine the validity of a translated and culturally adapted version of the Physicians' Reaction to Uncertainty scales (PRU) in primary care physicians. Methods In a structured process, the original questionnaire was translated, culturally adapted and assessed after administering it to 93 GPs. Test-retest reliability was tested by sending the questionnaire to the GPs again after two weeks. Results The principal factor analysis confirmed the postulated four-factor structure underlying the 15 items. In contrast to the original version, item 5 achieved a higher loading on the 'concern about bad outcomes' scale. Consequently, we rearranged the scales. Good item-scale correlations were obtained, with Pearson's correlation coefficient ranging from 0.56–0.84. As regards the item-discriminant validity between the scales 'anxiety due to uncertainty' and 'concern about bad outcomes', partially high correlations (Pearson's correlation coefficient 0.02–0.69; p < 0.001) were found, indicating an overlap between both constructs. The assessment of internal consistency revealed satisfactory values; Cronbach's alpha of the rearranged version was 0.86 or higher for all scales. Test-retest-reliability, assessed by means of the intraclass-correlation-coefficient (ICC), exceeded 0.84, except for the 'reluctance to disclose mistakes to physicians' scale (ICC = 0.66). In this scale, some substantial floor effects occurred, with 29.3% of answers showing the lowest possible value. Conclusion Dealing with uncertainty is an important issue in daily practice. The psychometric properties of the rearranged German version of the PRU are satisfying. The revealed floor effects do not limit the significance of the questionnaire. Thus, the German version of the PRU could contribute to the further evaluation of the impact of uncertainty in primary care physicians. PMID:17562018
Gunaydin, Gurkan; Citaker, Seyit; Meray, Jale; Cobanoglu, Gamze; Gunaydin, Ozge Ece; Hazar Kanik, Zeynep
2016-11-01
Validation of a self-report questionnaire. The purpose of this study was to investigate adaptation, validity, and reliability of the Turkish version of the Bournemouth Questionnaire. Low back pain is one of the most frequent disorders leading to activity limitation. This pain affects most of people in their lives. The most important point to evaluate patient's functional abilities and to decide a successful therapy procedure is to manage the assessment questionnaires precisely. One hundred ten patients with chronic low back pain were included in present study. To assess reliability, test-retest and internal consistency analyses were applied. The results of test-retest analysis were assessed by using Intraclass Correlation Coefficient method (95% confidence interval). For internal consistency, Cronbach alpha value was calculated. Validity of the questionnaire was assessed in terms of construct validity. For construct validity, factor analysis and convergent validity were tested. For convergent validity, total points of the Bournemouth Questionnaire were assessed with the total points of Quebec Back Pain Disability Scale and Roland Morris Disability Questionnaire by using Pearson correlation coefficient analysis. Cronbach alpha value was found 0.914, showing that this questionnaire has high internal consistency. The results of test-retest analysis were varying between 0.851 and 0.927, which shows that test-retest results are highly correlated. Factor analysis test indicated that this questionnaire had one factor. Pearson correlation coefficient of the Bournemouth Questionnaire with Roland Morris Disability Questionnaire was calculated 0.703 and it was found with Quebec Back Pain Disability Scale is 0.659. These results showed that the Bournemouth Questionnaire is very good correlated with Roland Morris Disability Questionnaire and Quebec Back Pain Disability Scale. The Turkish version of the Bournemouth Questionnaire is valid and reliable. 3.
Uncertainty Analysis of Downscaled CMIP5 Precipitation Data for Louisiana, USA
NASA Astrophysics Data System (ADS)
Sumi, S. J.; Tamanna, M.; Chivoiu, B.; Habib, E. H.
2014-12-01
The downscaled CMIP3 and CMIP5 Climate and Hydrology Projections dataset contains fine spatial resolution translations of climate projections over the contiguous United States developed using two downscaling techniques (monthly Bias Correction Spatial Disaggregation (BCSD) and daily Bias Correction Constructed Analogs (BCCA)). The objective of this study is to assess the uncertainty of the CMIP5 downscaled general circulation models (GCM). We performed an analysis of the daily, monthly, seasonal and annual variability of precipitation downloaded from the Downscaled CMIP3 and CMIP5 Climate and Hydrology Projections website for the state of Louisiana, USA at 0.125° x 0.125° resolution. A data set of daily gridded observations of precipitation of a rectangular boundary covering Louisiana is used to assess the validity of 21 downscaled GCMs for the 1950-1999 period. The following statistics are computed using the CMIP5 observed dataset with respect to the 21 models: the correlation coefficient, the bias, the normalized bias, the mean absolute error (MAE), the mean absolute percentage error (MAPE), and the root mean square error (RMSE). A measure of variability simulated by each model is computed as the ratio of its standard deviation, in both space and time, to the corresponding standard deviation of the observation. The correlation and MAPE statistics are also computed for each of the nine climate divisions of Louisiana. Some of the patterns that we observed are: 1) Average annual precipitation rate shows similar spatial distribution for all the models within a range of 3.27 to 4.75 mm/day from Northwest to Southeast. 2) Standard deviation of summer (JJA) precipitation (mm/day) for the models maintains lower value than the observation whereas they have similar spatial patterns and range of values in winter (NDJ). 3) Correlation coefficients of annual precipitation of models against observation have a range of -0.48 to 0.36 with variable spatial distribution by model. 4) Most of the models show negative correlation coefficients in summer and positive in winter. 5) MAE shows similar spatial distribution for all the models within a range of 5.20 to 7.43 mm/day from Northwest to Southeast of Louisiana. 6) Highest values of correlation coefficients are found at seasonal scale within a range of 0.36 to 0.46.
T2 Mapping of the Sacroiliac Joints With 3-T MRI: A Preliminary Study.
Lefebvre, Guillaume; Bergère, Antonin; Rafei, Mazen El; Duhamel, Alain; Teixeira, Pedro; Cotten, Anne
2017-08-01
The objective of this study was to assess the feasibility of T2 relaxation time measurements of the sacroiliac joints. The sacroiliac joints of 40 patients were imaged by 3-T MRI using an oblique axial multislice multiecho spin-echo T2-weighted sequence. Manual plotting and automatic subdivision of ROIs allowed us to obtain T2 values for up to 48 different areas per patient (posterior and anterior parts, sacral, intermediate, and iliac parts). Intraand interobserver reproducibility of T2 values were calculated after independent assessment by two musculoskeletal radiologists. A total of 1656 measurement sites could be analyzed. Mean (± SD) T2 values were 40.6 ± 6.7 ms and 41.2 ± 6.3 ms for observer 1 and 39.9 ± 6.6 ms for observer 2. The intraobserver intraclass correlation coefficient was 0.72 (95% CI, 0.70-0.74), and the interobserver intraclass correlation coefficient was 0.71 (95% CI, 0.68-0.72). Our study shows the feasibility of T2 relaxation time measurements at the sacroiliac joints.
Vermicomposting of food waste: assessing the stability and maturity
2012-01-01
The vermicompost using earthworms (Eisenia Fetida) was produced from food waste and chemical parameters (EC, pH, carbon to nitrogen contents (C/N)) and germination bioassay was examined in order to assess the stability and maturity indicators during the vermicomposting process. The seed used in the germination bioassay was cress. The ranges of EC, pH, C/N and germination index were 7.5-4.9 mS/cm, 5.6-7.53, 30.13-14.32% and 12.8-58.4%, respectively. The germination index (GI) value revealed that vermicompost rendered as moderate phytotoxic to cress seed. Pearson correlation coefficient was used to evaluate the relationship between the parameters. High statistically significant correlation coefficient was calculated between the GI value and EC in the vermicompost at the 99% confidence level. The C/N value showed that the vermicompost was stable. As a result of these observations, stability test alone, was not able to ensure high vermicompost quality. Therefore, it appears that determining vermicompost quality requires a simultaneous use of maturity and stability tests. PMID:23369642
A pilot study of river flow prediction in urban area based on phase space reconstruction
NASA Astrophysics Data System (ADS)
Adenan, Nur Hamiza; Hamid, Nor Zila Abd; Mohamed, Zulkifley; Noorani, Mohd Salmi Md
2017-08-01
River flow prediction is significantly related to urban hydrology impact which can provide information to solve any problems such as flood in urban area. The daily river flow of Klang River, Malaysia was chosen to be forecasted in this pilot study which based on phase space reconstruction. The reconstruction of phase space involves a single variable of river flow data to m-dimensional phase space in which the dimension (m) is based on the optimal values of Cao method. The results from the reconstruction of phase space have been used in the forecasting process using local linear approximation method. From our investigation, river flow at Klang River is chaotic based on the analysis from Cao method. The overall results provide good value of correlation coefficient. The value of correlation coefficient is acceptable since the area of the case study is influence by a lot of factors. Therefore, this pilot study may be proposed to forecast daily river flow data with the purpose of providing information about the flow of the river system in urban area.
Babín, María del Mar; Sanz, Paloma; Concejero, Miguel Angel; Martínez, María Angeles; Tarazona, José Vicente
2010-08-01
High-resolution gas chromatography/mass spectrometry (HRGC/MS) is the standard method for analysing dioxin, furan and polybrominated retardants in hazardous waste. Determination of dioxin-like compounds using in vitro bioassays such as ethoxyresorufin-O-deethylase (EROD) is an important tool to evaluate their Ah receptor-mediated toxic effects, because it detects all arylhydrocarbon receptor ligands in a variety of sample matrices. In the present work, we compared RTG-2 cell line EROD bioassay with HRGC/MS for assessing waste samples (liquid and solid) contaminated with polychlorinated dibenzo-p-dioxins and dibenzofurans, polychlorinated biphenyls (dioxin-like PCBs) and other xenobiotics. For liquid samples, HRGC/MS-toxic equivalent (HRGC/MS-TEQ) values ranged from 273.26 to 5.84 ng TEQ l(-1) and correlated well (correlation coefficient 0.99) with values obtained by EROD-TEQ, which ranged from 128 to 2.5 ng TEQ l(-1). For solid samples, HRGC/MS-TEQ values ranged from 3.44 to 0.49 ng TEQ g(-1) and correlated less well than liquid samples (correlation coefficient 0.64) with values obtained by EROD-TEQ ranging from 2.27 to 0.93 ng TEQ g(-1). The overestimation of RTG-2 EROD-TEQ (1.2 +/- 0.92 of values established by HRGC/MS) and the absence of false-negative results may limit analytical costs by eliminating the need for follow-up GC/MS analysis on the negative samples. We suggest that RTG-2 EROD bioassay is an inexpensive means for preliminary dioxin and furan positive screenings of waste samples. (c) 2010 John Wiley & Sons, Ltd.
Georgieva-Zhostova, Spaska; Kolev, Ognyan I; Stambolieva, Katerina
2014-09-01
The aim of the present study was the translation, cross-cultural adaptation and validation of the Dizziness Handicap Inventory in Bulgarian language (DHI-BG). Ninety-seven vestibular patients (19 men and 78 women, mean age 45.08 ± 13.85 years) took part in the investigation. All participants were asked to fill in the DHI-BG. Internal consistency was estimated using Cronbach's alpha and item-total correlation, reproducibility by calculating Bland-Altman's limits of agreement and intraclass correlation coefficients (ICCs). Associations were estimated by Spearman's correlation coefficients. The Cronbach's alpha for the total score, functional, physical and emotional subscales of DHI-BG were 0.88, 0.75, 0.72 and 0.81. The floor and ceiling effects of the DHI-BG total scale were evaluated with respect to the limits of agreement which were ±9.4-14.53 points. Intraclass correlation coefficients (ICCs) for all scale and subscales were higher than the recommended value of 0.75 and determined good test-retest reliability. The range of items correlation for DHI-BG was from 0.27 (item 12) to 0.72 (item 3). No significant differences were observed in the Cronbach's alpha coefficients between the DHI-BG and the original version, the German and Italian versions of the questionnaire. The most significant difference was observed in comparison with the German version of DHI. Construct validity presented a moderate correlation between Romberg coefficients and DHI-BG scores and strong correlation between all scores of DHI and the self-perceived disability. The results suggest that DHI-BG scores show a good discriminative validity between groups with different levels of self-assessed disability. The Bulgarian version of the DHI is a reliable and valid tool in assessing the impact of dizziness on the quality of life in Bulgarian vestibular patients.
Calculation of Drug Solubilities by Pharmacy Students.
ERIC Educational Resources Information Center
Cates, Lindley A.
1981-01-01
A method of estimating the solubilities of drugs in water is reported that is based on a principle applied in quantitative structure-activity relationships. This procedure involves correlation of partition coefficient values using the octanol/water system and aqueous solubility. (Author/MLW)
NASA Technical Reports Server (NTRS)
Ristorcelli, J. R.; Lumley, J. L.; Abid, R.
1994-01-01
A nonlinear representation for the rapid-pressure correlation appearing in the Reynolds stress equations, consistent with the Taylor-Proudman theorem, is presented. The representation insures that the modeled second-order equations are frame-invariant with respect to rotation when the flow is two-dimensional in planes perpendicular to the axis of rotation. The representation satisfies realizability in a new way: a special ansatz is used to obtain analytically, the values of coefficients valid away from the realizability limit: the model coefficients are functions of the state of the turbulence that are valid for all states of the mechanical turbulence attaining their constant limiting values only when the limit state is achieved. Utilization of all the mathematical constraints are not enough to specify all the coefficients in the model. The unspecified coefficients appear as free parameters which are used to insure that the representation is asymptotically consistent with the known equilibrium states of a homogeneous sheared turbulence. This is done by insuring that the modeled evolution equations have the same fixed points as those obtained from computer and laboratory experiments for the homogeneous shear. Results of computations of the homogeneous shear, with and without rotation, and with stabilizing and destabilizing curvature, are shown. Results are consistently better, in a wide class of flows which the model not been calibrated, than those obtained with other nonlinear models.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saha, Ashirbani, E-mail: as698@duke.edu; Grimm, La
Purpose: To assess the interobserver variability of readers when outlining breast tumors in MRI, study the reasons behind the variability, and quantify the effect of the variability on algorithmic imaging features extracted from breast MRI. Methods: Four readers annotated breast tumors from the MRI examinations of 50 patients from one institution using a bounding box to indicate a tumor. All of the annotated tumors were biopsy proven cancers. The similarity of bounding boxes was analyzed using Dice coefficients. An automatic tumor segmentation algorithm was used to segment tumors from the readers’ annotations. The segmented tumors were then compared between readersmore » using Dice coefficients as the similarity metric. Cases showing high interobserver variability (average Dice coefficient <0.8) after segmentation were analyzed by a panel of radiologists to identify the reasons causing the low level of agreement. Furthermore, an imaging feature, quantifying tumor and breast tissue enhancement dynamics, was extracted from each segmented tumor for a patient. Pearson’s correlation coefficients were computed between the features for each pair of readers to assess the effect of the annotation on the feature values. Finally, the authors quantified the extent of variation in feature values caused by each of the individual reasons for low agreement. Results: The average agreement between readers in terms of the overlap (Dice coefficient) of the bounding box was 0.60. Automatic segmentation of tumor improved the average Dice coefficient for 92% of the cases to the average value of 0.77. The mean agreement between readers expressed by the correlation coefficient for the imaging feature was 0.96. Conclusions: There is a moderate variability between readers when identifying the rectangular outline of breast tumors on MRI. This variability is alleviated by the automatic segmentation of the tumors. Furthermore, the moderate interobserver variability in terms of the bounding box does not translate into a considerable variability in terms of assessment of enhancement dynamics. The authors propose some additional ways to further reduce the interobserver variability.« less
Zhou, Nan; Chu, Chen; Dou, Xin; Chen, Weibo; He, Jian; Yan, Jing; Zhou, Zhengyang; Yang, Xiaofeng
2018-02-08
Radiation-induced parotid damage is a common complication in patients with nasopharyngeal carcinoma (NPC) treated with radiotherapy to head and neck region, which severely reduce the life quality of those patients. The aim of this study was to early evaluate the changes of irradiated parotid glands with T2 mapping and mDIXON Quant imaging. Forty-one patients with NPC underwent conventional magnetic resonance imaging for nasopharynx and neck, and T2 mapping and mDIXON Quant imaging for bilateral parotid glands within 2 weeks before radiotherapy (pre-RT), 5 weeks after the beginning of radiotherapy (mid-RT), and 4 weeks after radiotherapy (post-RT). Parotid volume, T2 values, fat fraction (FF) values, and mean radiation dose were recorded and analyzed. From pre-RT to mid-RT, parotid volume decreased (atrophy rate, 27.0 ± 11.5%), while parotid T2 and FF values increased (change rate, 6.0 ± 6.2% for T2 value and 9.1 ± 9.9% for FF value) significantly. From mid-RT to post-RT, parotid T2 value continuously increased (change rate, 4.6 ± 7.7%), but parotid FF value decreased (change rate, - 9.9 ± 18.2%) significantly. Change rate of parotid T2 value significantly correlated with parotid atrophy rate from pre-RT to post-RT (r = 0.313, P = 0.027). Multiple linear regression analysis showed that parotid T2 value (standardized coefficient [SC] = - 0.259, P = 0.001) and FF value (SC = - 0.320, P = 0.014) negatively correlated with parotid volume, while parotid T2 value positively correlated with MR scan time point (SC = 0.476, P = 0.001) significantly. Parotid T2 and FF values showed excellent reproducibility (intraclass correlation coefficient, 0.935-0.992). T2 mapping and mDIXON Quant imaging is useful for noninvasive evaluation of radiation-induced parotid damage.
Wang, Lin; Zhao, Dong-Zhi; Yang, Jian-Hong; Chen, Yan-Long
2010-12-01
Chromophoric dissolved organic matter (CDOM) near ultraviolet absorption spectra contains CDOM molecular structure, composition and other important physical and chemical information. Based on the measured data of CDOM absorption coefficient in March 2009 in the north area of Yellow Sea, the present paper analyzed near ultraviolet absorption spectral properties of CDOM. The results showed that due to the impact of near-shore terrigenous input, the composition of CDOM is quite different in the north area of Yellow Sea, and this area is a typical case II water; fitted slope with specific range of spectral band and absorption coefficient at specific band can indicate the relative size of CDOM molecular weight, correlation between spectral slope of the Sg,275-300), Sg,300-350, Sg,350-400 and Sg,250-275 and the relative size of CDOM molecular weight indicative parameter M increases in turn and the highest is up to 0.95. Correlation between a(g)(lambda) and M value increases gradually with the increase in wavelength, and the highest is up to 0.92 at 400 nm; being correlated or not between spectral slope and absorption coefficient is decided by the fitting-band wavelength range for the spectra slope and the wavelength for absorption coefficient. Correlation between Sg,275-300 and a(g)(400) is the largest, up to 0.87.
Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio
2017-01-17
Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5)) -18 ) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin's concordance correlation coefficient, linear regression, Bland-Altman's agreement analysis, concordance correlation coefficient ( ρc ) and the coefficient of determination ( R ²) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R ² = 0.384, p < 0.001. A paired-sample t -test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = -6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin's concordance correlation coefficient was poor ( ρc = 0.014, 95% CI = -0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels.
Correlation of Zn2+ content with aflatoxin content of corn.
Failla, L J; Lynn, D; Niehaus, W G
1986-01-01
Forty-nine samples from the 1983 Virginia corn harvest were analyzed for aflatoxin, zinc, copper, iron, and manganese content. Values (mean +/- standard deviation) were as follows: aflatoxin, 117 +/- 360 micrograms/kg; zinc, 22.5 +/- 3.4 mg/kg; copper, 2.27 +/- 0.56 mg/kg; iron, 40.8 +/- 18.7 mg/kg; and manganese, 5.1 +/- 1.1 mg/kg. Aflatoxin levels positively correlated with zinc (Spearman correlation coefficient, 0.385; P less than 0.006) and copper levels (Spearman correlation coefficient, 0.573; P less than 0.0001). Based on biochemical data in the literature, we believe that the correlation with zinc is important and that there may be a cause-and-effect relationship between zinc levels in corn and aflatoxin levels which are produced upon infection with Aspergillus flavus or A. parasiticus. Control of aflatoxin contamination in field corn by decreasing the zinc levels may be feasible, but no methods to decrease zinc levels are currently available. PMID:3729406
Overcoming multicollinearity in multiple regression using correlation coefficient
NASA Astrophysics Data System (ADS)
Zainodin, H. J.; Yap, S. J.
2013-09-01
Multicollinearity happens when there are high correlations among independent variables. In this case, it would be difficult to distinguish between the contributions of these independent variables to that of the dependent variable as they may compete to explain much of the similar variance. Besides, the problem of multicollinearity also violates the assumption of multiple regression: that there is no collinearity among the possible independent variables. Thus, an alternative approach is introduced in overcoming the multicollinearity problem in achieving a well represented model eventually. This approach is accomplished by removing the multicollinearity source variables on the basis of the correlation coefficient values based on full correlation matrix. Using the full correlation matrix can facilitate the implementation of Excel function in removing the multicollinearity source variables. It is found that this procedure is easier and time-saving especially when dealing with greater number of independent variables in a model and a large number of all possible models. Hence, in this paper detailed insight of the procedure is shown, compared and implemented.
Duval, Jérôme F L; Slaveykova, Vera I; Hosse, Monika; Buffle, Jacques; Wilkinson, Kevin J
2006-10-01
The electrostatic, hydrodynamic and conformational properties of aqueous solutions of succinoglycan have been analyzed by fluorescence correlation spectroscopy (FCS), proton titration, and capillary electrophoresis (CE) over a large range of pH values and electrolyte (NaCl) concentrations. Using the theoretical formalism developed previously for the electrokinetic properties of soft, permeable particles, a quantitative analysis for the electro-hydrodynamics of succinoglycan is performed by taking into account, in a self-consistent manner, the measured values of the diffusion coefficients, electric charge densities, and electrophoretic mobilities. For that purpose, two limiting conformations for the polysaccharide in solution are tested, i.e. succinoglycan behaves as (i) a spherical, random coil polymer or (ii) a rodlike particle with charged lateral chains. The results show that satisfactory modeling of the titration data for ionic strengths larger than 50 mM can be accomplished using both geometries over the entire range of pH values. Electrophoretic mobilities measured for sufficiently large pH values (pH > 5-6) are in line with predictions based on either model. The best manner to discriminate between these two conceptual models is briefly discussed. For low pH values (pH < 5), both models indicate aggregation, resulting in an increase of the hydrodynamic permeability and a decrease of the diffusion coefficient.
Wang, Luman; Mo, Qiaochu; Wang, Jianxin
2015-01-01
Most current gene coexpression databases support the analysis for linear correlation of gene pairs, but not nonlinear correlation of them, which hinders precisely evaluating the gene-gene coexpression strengths. Here, we report a new database, MIrExpress, which takes advantage of the information theory, as well as the Pearson linear correlation method, to measure the linear correlation, nonlinear correlation, and their hybrid of cell-specific gene coexpressions in immune cells. For a given gene pair or probe set pair input by web users, both mutual information (MI) and Pearson correlation coefficient (r) are calculated, and several corresponding values are reported to reflect their coexpression correlation nature, including MI and r values, their respective rank orderings, their rank comparison, and their hybrid correlation value. Furthermore, for a given gene, the top 10 most relevant genes to it are displayed with the MI, r, or their hybrid perspective, respectively. Currently, the database totally includes 16 human cell groups, involving 20,283 human genes. The expression data and the calculated correlation results from the database are interactively accessible on the web page and can be implemented for other related applications and researches. PMID:26881263
Wang, Luman; Mo, Qiaochu; Wang, Jianxin
2015-01-01
Most current gene coexpression databases support the analysis for linear correlation of gene pairs, but not nonlinear correlation of them, which hinders precisely evaluating the gene-gene coexpression strengths. Here, we report a new database, MIrExpress, which takes advantage of the information theory, as well as the Pearson linear correlation method, to measure the linear correlation, nonlinear correlation, and their hybrid of cell-specific gene coexpressions in immune cells. For a given gene pair or probe set pair input by web users, both mutual information (MI) and Pearson correlation coefficient (r) are calculated, and several corresponding values are reported to reflect their coexpression correlation nature, including MI and r values, their respective rank orderings, their rank comparison, and their hybrid correlation value. Furthermore, for a given gene, the top 10 most relevant genes to it are displayed with the MI, r, or their hybrid perspective, respectively. Currently, the database totally includes 16 human cell groups, involving 20,283 human genes. The expression data and the calculated correlation results from the database are interactively accessible on the web page and can be implemented for other related applications and researches.
Samartsev, V N; Kozhina, O V; Polishchuk, L S
2005-01-01
It is known that mitochondrial respiration in state 3 is due to three simultaneous and independent processes: synthesis of ATP (1), endogenous passive proton leakage (2), and proton leakage by protonophoric uncoupler (3). The total rate of processes (2) and (3) is equal to the product of respiration rate in state 4 and coefficient KR, which is defined as the ratio of the deltamuH+ value in state 3 to that in state 4. It is shown that it is possible to calculate both the rates of processes (1), (2) and (3) separately and the protonophoric activity of uncoupler using the coefficient KR and other coefficients, which are determined as the ratio of deltamuH+ values in state 3 or in state 4 to its maximal value. Simple methods of determination of these coefficients were developed, which are based on the study of the dependence of respiration rate in states 3 and 4 on the concentration of protonophoric uncoupler. It was found that the uncoupling action of palmitate, a natural uncoupler of oxidative phosphorylation, unlike classic uncoupler-protonophores DNP and FCCP, depends not only on its protonophoric activity but also on the inhibition of the process (1).
Seismic zoning (first approximation) using data of the main geomagnetic field
NASA Astrophysics Data System (ADS)
Khachikyan, Galina; Zhumabayev, Beibit; Toyshiev, Nursultan; Kairatkyzy, Dina; Seraliyev, Alibek; Khassanov, Eldar
2017-04-01
Seismic zoning is among the most complicated and extremely important problems of modern seismology. In solving this problem, a very important parameter is maximal possible earthquake magnitude (Mmax) which is believed at present depends on horizontal size of geoblocks. At the same time, it was found by Khachikyan et al. [2012, IJG, doi: 10.4236/ijg.2012.35109] that Mmax value in any seismic region may be determined using Z_GSM value that is geomagnetic Z-component in this region estimated in geocentric solar-magnetosphere coordinate system (GSM). On the base of the global seismological catalog NEIC with M≥4.5 for 1973-2010 years, and the International Geomagnetic Reference Field (IGRF) model, an empirical relation was obtained as follows: Mmax= a + b {log[abs(Z_GSM)]}. For the case of the whole planet, obtained empirical coefficients are as follows: a = (5,22 ± 0,17), and b = (0,78 ± 0,06) with correlation coefficient R=0.91, standard deviation SD=0.56, and probability 95%. Further investigations showed that the coefficients of the regression equation are different for different seismically active regions of the planet. For example, to the territory of the San Andreas Fault, defined by the coordinates 30-45N, 105-135W obtained values are as follows: a = (4,04 ± 0.38) and b = (0.7 ± 0.13) with correlation coefficient R = 0.91, standard deviation SD = 0.34, and probability of 95%. For territory of inland seismicity in Eurasia defined by the coordinates 30-45N, 0-110E, a = (12.44 ± 0.48) and b = (1,15 ± 0.2) with correlation coefficient R = 0.87, standard deviation SD = 0.98, and probability of 95%, and for the territory of the strongest seismicity in the world defined by the coordinates 20S-20N, 90-150E, obtained values of a = (- 17.5 ± 1,5) and b = (5,7 ± 0.4) with correlation coefficient R = 0.97, standard deviation SD = 0.4, and probability of 95%. The relationship between the intensity of the main geomagnetic field and released seismic energy is expectable, because both the main geomagnetic field and the tectonic activity of the planet originate from the same source - the convection in the Earth's liquid core. The relationship between earthquake magnitude and geomagnetic Z - component expressed namely in geocentric solar magnetosphere coordinate system (GSM), in which the interaction of the solar wind magnetic field with the geomagnetic field is better ordered, indicates at the external (triggering) earthquake occurrence in the extremely stressed tectonic area. Above empirical relationships may be used (in first approximation) for global seismic zoning and for prediction of possible Mmax, when a place and time of earthquake occurrence are predicted. In report we present global maps of Z_GSM and Mmax estimated for different seasons and different times.
Modification of surface morphology of Ti6Al4V alloy manufactured by Laser Sintering
NASA Astrophysics Data System (ADS)
Draganovská, Dagmar; Ižariková, Gabriela; Guzanová, Anna; Brezinová, Janette; Koncz, Juraj
2016-06-01
The paper deals with the evaluation of relation between roughness parameters of Ti6Al4V alloy produced by DMLS and modified by abrasive blasting. There were two types of blasting abrasives that were used - white corundum and Zirblast at three levels of air pressure. The effect of pressure on the value of individual roughness parameters and an influence of blasting media on the parameters for samples blasted by white corundum and Zirblast were evaluated by ANOVA. Based on the measured values, the correlation matrix was set and the standard of correlation statistic importance between the monitored parameters was determined from it. The correlation coefficient was also set.
RESPONSE FUNCTIONS FOR COMPUTING ABSORBED DOSE TO SKELETAL TISSUES FROM NEUTRON IRRADIATION
Bahadori, Amir A.; Johnson, Perry; Jokisch, Derek W.; Eckerman, Keith F.; Bolch, Wesley E.
2016-01-01
Spongiosa in the adult human skeleton consists of three tissues - active marrow (AM), inactive marrow (IM), and trabecularized mineral bone (TB). Active marrow is considered to be the target tissue for assessment of both long-term leukemia risk and acute marrow toxicity following radiation exposure. The total shallow marrow (TM50), defined as all tissues laying within the first 50 μm the bone surfaces, is considered to be the radiation target tissue of relevance for radiogenic bone cancer induction. For irradiation by sources external to the body, kerma to homogeneous spongiosa has been used as a surrogate for absorbed dose to both of these tissues, as direct dose calculations are not possible using computational phantoms with homogenized spongiosa. Recent microCT imaging of a 40-year-old male cadaver has allowed for the accurate modeling of the fine microscopic structure of spongiosa in many regions of the adult skeleton [Hough et al PMB (2011)]. This microstructure, along with associated masses and tissue compositions, was used to compute specific absorbed fractions (SAF) values for protons originating in axial and appendicular bone sites [Jokisch et al PMB (submitted)]. These proton SAFs, bone masses, tissue compositions, and proton production cross-sections, were subsequently used to construct neutron dose response functions (DRFs) for both AM and TM50 targets in each bone of the reference adult male. Kerma conditions were assumed for other resultant charged particles. For comparison, active marrow, total shallow marrow, and spongiosa kerma coefficients were also calculated. At low incident neutron energies, AM kerma coefficients for neutrons correlate well with values of the AM DRF, while total marrow (TM) kerma coefficients correlate well with values of the TM50 DRF. At high incident neutron energies, all kerma coefficients and DRFs tend to converge as charged particle equilibrium (CPE) is established across the bone site. In the range of 10 eV to 100 MeV, substantial differences are observed among the kerma coefficients and DRF. As a result, it is recommended that the AM kerma coefficient be used to estimate the AM DRF, and that the TM kerma coefficient be used to estimate the TM50 DRF below 10 eV. Between 10 eV and 100 MeV, the appropriate DRF should be used as presented in this study. Above 100 MeV, spongiosa kerma coefficients apply well for estimating skeletal tissue doses. DRF values for each bone site as a function of energy are provided in an electronic annex to this article. PMID:21983525
NASA Astrophysics Data System (ADS)
Seetha, N.; Raoof, Amir; Mohan Kumar, M. S.; Majid Hassanizadeh, S.
2017-05-01
Transport and deposition of nanoparticles in porous media is a multi-scale problem governed by several pore-scale processes, and hence, it is critical to link the processes at pore scale to the Darcy-scale behavior. In this study, using pore network modeling, we develop correlation equations for deposition rate coefficients for nanoparticle transport under unfavorable conditions at the Darcy scale based on pore-scale mechanisms. The upscaling tool is a multi-directional pore-network model consisting of an interconnected network of pores with variable connectivities. Correlation equations describing the pore-averaged deposition rate coefficients under unfavorable conditions in a cylindrical pore, developed in our earlier studies, are employed for each pore element. Pore-network simulations are performed for a wide range of parameter values to obtain the breakthrough curves of nanoparticle concentration. The latter is fitted with macroscopic 1-D advection-dispersion equation with a two-site linear reversible deposition accounting for both equilibrium and kinetic sorption. This leads to the estimation of three Darcy-scale deposition coefficients: distribution coefficient, kinetic rate constant, and the fraction of equilibrium sites. The correlation equations for the Darcy-scale deposition coefficients, under unfavorable conditions, are provided as a function of measurable Darcy-scale parameters, including: porosity, mean pore throat radius, mean pore water velocity, nanoparticle radius, ionic strength, dielectric constant, viscosity, temperature, and surface potentials of the particle and grain surfaces. The correlation equations are found to be consistent with the available experimental results, and in qualitative agreement with Colloid Filtration Theory for all parameters, except for the mean pore water velocity and nanoparticle radius.
Validation of MODIS Aerosol Optical Depth Retrievals over a Tropical Urban Site, Pune, India
NASA Technical Reports Server (NTRS)
More, Sanjay; Kuman, P. Pradeep; Gupta, Pawan; Devara, P. C. S.; Aher, G. R.
2011-01-01
In the present paper, MODIS (Terra and Aqua; level 2, collection 5) derived aerosoloptical depths (AODs) are compared with the ground-based measurements obtained from AERONET (level 2.0) and Microtops - II sun-photometer over a tropical urban station, Pune (18 deg 32'N; 73 deg 49'E, 559 m amsl). This is the first ever systematic validation of the MODIS aerosol products over Pune. Analysis of the data indicates that the Terra and Aqua MODIS AOD retrievals at 550 nm have good correlations with the AERONET and Microtops - II sun-photometer AOD measurements. During winter the linear regression correlation coefficients for MODIS products against AERONET measurements are 0.79 for Terra and 0.62 for Aqua; however for premonsoon, the corresponding coefficients are 0.78 and 0.74. Similarly, the linear regression correlation coefficients for Microtops measurements against MODIS products are 0.72 and 0.93 for Terra and Aqua data respectively during winter and are 0.78 and 0.75 during pre-monsoon. On yearly basis in 2008-2009, correlation coefficients for MODIS products against AERONET measurements are 0.80 and 0.78 for Terra and Aqua respectively while the corresponding coefficients are 0.70 and 0.73 during 2009-2010. The regressed intercepts with MODIS vs. AERONET are 0.09 for Terra and 0.05 for Aqua during winter whereas their values are 0.04 and 0.07 during pre-monsoon. However, MODIS AODs are found to underestimate during winter and overestimate during pre-monsoon with respect to AERONET and Microtops measurements having slopes 0.63 (Terra) and 0.74 (Aqua) during winter and 0.97 (Terra) and 0.94 (Aqua) during pre-monsoon. Wavelength dependency of Single Scattering Albedo (SSA) shows presence of absorbing and scattering aerosol particles. For winter, SSA decreases with wavelength with the values 0.86 +/- 0.03 at 440 nm and 0.82 +/- 0.04 at 1020nm. In pre-monsoon, it increases with wavelength (SSA is 0.87 +/- 0.02 at 440nm; and 0.88 +/-0.04 at 1020 nm).
Suárez, Inmaculada; Coto, Baudilio
2015-08-14
Average molecular weights and polydispersity indexes are some of the most important parameters considered in the polymer characterization. Usually, gel permeation chromatography (GPC) and multi angle light scattering (MALS) are used for this determination, but GPC values are overestimated due to the dispersion introduced by the column separation. Several procedures were proposed to correct such effect usually involving more complex calibration processes. In this work, a new method of calculation has been considered including diffusion effects. An equation for the concentration profile due to diffusion effects along the GPC column was considered to be a Fickian function and polystyrene narrow standards were used to determine effective diffusion coefficients. The molecular weight distribution function of mono and poly disperse polymers was interpreted as a sum of several Fickian functions representing a sample formed by only few kind of polymer chains with specific molecular weight and diffusion coefficient. Proposed model accurately fit the concentration profile along the whole elution time range as checked by the computed standard deviation. Molecular weights obtained by this new method are similar to those obtained by MALS or traditional GPC while polydispersity index values are intermediate between those obtained by the traditional GPC combined to Universal Calibration method and the MALS method. Values for Pearson and Lin coefficients shows improvement in the correlation of polydispersity index values determined by GPC and MALS methods when diffusion coefficients and new methods are used. Copyright © 2015 Elsevier B.V. All rights reserved.
Study of Left Ventricular Mass and Its Determinants on Echocardiography.
Guleri, Namrata; Rana, Susheela; Chauhan, Randhir S; Negi, Prakash Chand; Diwan, Yogesh; Diwan, Deepa
2017-09-01
Increased Left Ventricular Mass (LVM) is an independent risk factor for cardiovascular morbidity and mortality. This study was done to find the prevalence and determinants of LVM in the Northern Indian population. A prospective cross-sectional observational study was carried out in a tertiary care centre in Himachal Pradesh, India and the study population included all consecutive patients fulfilling the inclusion criteria attending cardiology OPD on seeking medical attention with various symptoms for dyslipidaemia, hypertension but not on medication over a period of one year. Focused history was taken; physical examination and investigations were done. Data collected was analysed using Epi-info software version 3.5.1. We calculated means of LVM index for categorical variables i.e., sex, tobacco consumption, alcohol consumption and sedentary lifestyle etc., and also calculated p-values as test of significance for mean difference across the exposure variable groups. The Pearson correlation coefficient was calculated and 2 tailed significance at p< 0.05 was taken as statistically significant. Mean age of study population was 42.30±9.8 years and 62.9% were males. The mean LVM index was significantly higher in men than in women 77.7 ± 11.4 vs.71.3 ± 15.7 (p-value <0.01). Strong positive correlation was observed between increased waist hip ratio and increased Left Ventricular Mass Index (LVMI). The Pearson correlation coefficient was 36.77 and it was statistically significant with p-value 0.04. We found positive and independent correlation of increased LVMI with increased Waist Hip Ratio (WHR). A positive independent correlation was also observed with higher fasting blood sugar levels.
de Jong, Antoinette; Kwee, Thomas C; de Klerk, John MH; Adam, Judit A; de Keizer, Bart; Fijnheer, Rob; Kersten, Marie José; Ludwig, Inge; Jauw, Yvonne WS; Zijlstra, Josée M; den Bos, Indra C Pieters - Van; Stoker, Jaap; Hoekstra, Otto S; Nievelstein, Rutger AJ
2014-01-01
The purpose of this study was to determine the correlation between the 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET) standardized uptake value (SUV) and the diffusion-weighted magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) in newly diagnosed diffuse large B-cell lymphoma (DLBCL). Pretreatment FDG-PET and diffusion-weighted MRI of 21 patients with histologically proven DLBCL were prospectively analyzed. In each patient, maximum, mean and peak standardized uptake value (SUV) was measured in the lesion with visually highest FDG uptake and in the largest lesion. Mean ADC (ADCmean, calculated with b-values of 0 and 1000 s/mm2) was measured in the same lesions. Correlations between FDG-PET metrics (SUVmax, SUVmean, SUVpeak) and ADCmean were assessed using Pearson’s correlation coefficients. In the lesions with visually highest FDG uptake, no significant correlations were found between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.498, P=0.609 and P=0.595, respectively). In the largest lesions, there were no significant correlations either between the SUVmax, SUVmean, SUVpeak and the ADCmean (P=0.992, P=0.843 and P=0.894, respectively). The results of this study indicate that the glycolytic rate as measured by FDG-PET and changes in water compartmentalization and water diffusion as measured by the ADC are independent biological phenomena in newly diagnosed DLBCL. Further studies are warranted to assess the complementary roles of these different imaging biomarkers in the evaluation and follow-up of DLBCL. PMID:24795837
A 3D analysis of oxygen transfer in a low-cost micro-bioreactor for animal cell suspension culture.
Yu, P; Lee, T S; Zeng, Y; Low, H T
2007-01-01
A 3D numerical model was developed to study the flow field and oxygen transport in a micro-bioreactor with a rotating magnetic bar on the bottom to mix the culture medium. The Reynolds number (Re) was kept in the range of 100-716 to ensure laminar environment for animal cell culture. The volumetric oxygen transfer coefficient (k(L)a) was determined from the oxygen concentration distribution. It was found that the effect of the cell consumption on k(L)a could be negligible. A correlation was proposed to predict the liquid-phase oxygen transfer coefficient (k(Lm)) as a function of Re. The overall oxygen transfer coefficient (k(L)) was obtained by the two-resistance model. Another correlation, within an error of 15%, was proposed to estimate the minimum oxygen concentration to avoid cell hypoxia. By combination of the correlations, the maximum cell density, which the present micro-bioreactor could support, was predicted to be in the order of 10(12) cells m(-3). The results are comparable with typical values reported for animal cell growth in mechanically stirred bioreactors.
Chiou, C.T.; Schmedding, D.W.; Manes, M.
2005-01-01
A volume-fraction-based solvent-water partition model for dilute solutes, in which the partition coefficient shows a dependence on solute molar volume (V??), is adapted to predict the octanol-water partition coefficient (K ow) from the liquid or supercooled-liquid solute water solubility (Sw), or vice versa. The established correlation is tested for a wide range of industrial compounds and pesticides (e.g., halogenated aliphatic hydrocarbons, alkylbenzenes, halogenated benzenes, ethers, esters, PAHs, PCBs, organochlorines, organophosphates, carbamates, and amidesureas-triazines), which comprise a total of 215 test compounds spanning about 10 orders of magnitude in Sw and 8.5 orders of magnitude in Kow. Except for phenols and alcohols, which require special considerations of the Kow data, the correlation predicts the Kow within 0.1 log units for most compounds, much independent of the compound type or the magnitude in K ow. With reliable Sw and V data for compounds of interest, the correlation provides an effective means for either predicting the unavailable log Kow values or verifying the reliability of the reported log Kow data. ?? 2005 American Chemical Society.
Bengi, Göksel; Yalçın, Mustafa; Akpınar, Hale; Keskinoğlu, Pembe; Ellidokuz, Hülya
2015-07-01
There are few specific evaluation forms for evaluating the quality of life among patients with chronic constipation. Our study aimed to determine the validity and reliability of the translated Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire for the Turkish population because evidence of its reliability and validity is required to justify its use in other studies and clinical practice. This study included 154 patients with constipation who were treated at the Department of Gastroenterology, Dokuz Eylül University Hospital between January and June 2012. The translated PAC-QOL questionnaire was completed by patients at the clinic and also at a 2-week follow-up to test its reliability. Cronbach's alpha coefficient (internal consistency) was 0.91 (good) for the translated PAC-QOL questionnaire. Time validity was evaluated using the intraclass correlation coefficient (ICC) method, and the ICC value for all questions was confirmed as 0.68 at the 2-week follow-up. The validity of the tool in the study group was evaluated using factor analysis, and the results were highly significant (Kaiser-Meyer-Olkin value: 0.857; Bartlett's test: p=0.001). Questions were categorized according to six factors based on the factor analysis, and these factors explained 65.1% of the total variation. For hypothesis verification of the tool, the correlation coefficient for PAC-QOL and PAC Symptoms (PAC-SYM) was r=0.577 (p<0.001), whereas the correlation coefficient for PAC-QOL and constipation severity score was r=0.457 (p<0.001). The PAC-QOL questionnaire was reliable, although not valid because of the limited sample group.
Optical properties of size fractions of suspended particulate matter in littoral waters of Québec
NASA Astrophysics Data System (ADS)
Mohammadpour, Gholamreza; Gagné, Jean-Pierre; Larouche, Pierre; Montes-Hugo, Martin A.
2017-11-01
Mass-specific absorption (ai∗(λ)) and scattering (bi∗(λ)) coefficients were derived for four size fractions (i = 0.2-0.4, 0.4-0.7, 0.7-10, and > 10 µm, λ = wavelength in nm) of suspended particulate matter (SPM) and with samples obtained from surface waters (i.e., 0-2 m depth) of the Saint Lawrence Estuary and Saguenay Fjord (SLE-SF) during June of 2013. For the visible-near-infrared spectral range (i.e., λ = 400-710 nm), mass-specific absorption coefficients of total SPM (i.e., particulates > 0.2 µm) (hereafter aSPM∗) had low values (e.g., < 0.01 m2 g-1 at λ = 440 nm) in areas of the lower estuary dominated by particle assemblages with relatively large mean grain size and high particulate organic carbon and chlorophyll a per unit of mass of SPM. Conversely, largest aSPM∗ values (i.e., > 0.05 m2 g-1 at λ = 440 nm) corresponded with locations of the upper estuary and SF where particulates were mineral-rich and/or their mean diameter was relatively small. The variability of two optical proxies (the spectral slope of particulate beam attenuation coefficient and the mass-specific particulate absorption coefficient, hereafter γ and Svis, respectively) with respect to changes in particle size distribution (PSD) and chemical composition was also examined. The slope of the PSD was correlated with bi∗(550) (Spearman rank correlation coefficient ρs up to 0.37) and ai∗(440) estimates (ρs up to 0.32) in a comparable way. Conversely, the contribution of particulate inorganic matter to total mass of SPM (FSPMPIM) had a stronger correlation with ai∗ coefficients at a wavelength of 440 nm (ρs up to 0.50). The magnitude of γ was positively related to FSPMi or the contribution of size fraction i to the total mass of SPM (ρs up to 0.53 for i = 0.2-0.4 µm). Also, the relation between γ and FSPMPIM variability was secondary (ρs = -0.34, P > 0.05). Lastly, the magnitude of Svis was inversely correlated with aSPM∗(440) (ρs = -0.55, P = 0.04) and FSPMPIM (ρs = -0.62, P = 0.018) in sampling locations with a larger marine influence (i.e., lower estuary).
Xu, Shao-Kun; Hong, Xiang-Fei; Cheng, Yi-Bang; Liu, Chang-Yuan; Li, Yan; Yin, Bin; Wang, Ji-Guang
2018-03-01
Multiple piezoelectric pressure mechanotransducers topologized into an array might improve efficiency and accuracy in collecting arterial pressure waveforms for measurement of pulse wave velocity (PWV). In the present study, we validated a piezoelectric sensor array-based prototype (Philips) against the validated and clinically widely used Complior device (Alam Medical). We recruited 33 subjects with a wide distribution of PWV. For the validation, PWV was measured sequentially with the Complior device (four times) and the Philips prototype (three times). With the 99 paired PWV values, we investigated the agreement between the Philips prototype and the Complior device using Pearson correlation analysis and Bland-Altman plot. We also performed analysis on the determinants and reproducibility of PWV measured with both devices. The correlation coefficient for PWV measured with the two devices was 0.92 ( p < 0.0001). Compared with the Complior device, the Philips prototype slightly overestimated PWV by 0.24 (± 2 standard deviations, ± 1.91) m/s, especially when PWV was high. The correlation coefficient between the difference and the average of the Philips and Complior measurements was 0.21 ( p = 0.035). Nonetheless, they had similar determinants. Age, mean arterial pressure, and sex altogether explained 81.6 and 83.9% of the variance of PWV values measured with the Philips prototype and Complior device, respectively. When the two extremes of the three PWV values measured with the Philips prototype and the Complior device were investigated, the coefficients of variation were 8.26 and 3.26%, respectively. Compared with the Complior device, the Philips prototype had similar accuracy, determinants, and reproducibility in measuring PWV.
NASA Astrophysics Data System (ADS)
John, T. L.
1996-04-01
Free-free absorption coefficients of the negative neon ion are calculated by the phase-shift approximation based on multiconfiguration Hartree-Fock continuum wave functions. These wave functions accurately account for electron-neon correlation and polarization, and yield scattering cross-sections in excellent agreement with the latest experimental values. The coefficients are expected to give the best current estimates of Ne^- continuous absorption. We find that Ne^- makes only a small contribution (less than 0.3 per cent) to stellar opacities, including hydrogen-deficient stars with enhanced Ne abundances.
Stieltjes, Bram; Weikert, Thomas; Gatidis, Sergios; Wiese, Mark; Wild, Damian; Lardinois, Didier
2017-01-01
The minimum apparent diffusion coefficient (ADCmin) derived from diffusion-weighted MRI (DW-MRI) and the maximum standardized uptake value (SUVmax) of FDG-PET are markers of aggressiveness in lung cancer. The numeric correlation of the two parameters has been extensively studied, but their spatial interplay is not well understood. After FDG-PET and DW-MRI coregistration, values and location of ADCmin- and SUVmax-voxels were analyzed. The upper limit of the 95% confidence interval for registration accuracy of sequential PET/MRI was 12 mm, and the mean distance (D) between ADCmin- and SUVmax-voxels was 14.0 mm (average of two readers). Spatial mismatch (D > 12 mm) between ADCmin and SUVmax was found in 9/25 patients. A considerable number of mismatch cases (65%) was also seen in a control group that underwent simultaneous PET/MRI. In the entire patient cohort, no statistically significant correlation between SUVmax and ADCmin was seen, while a moderate negative linear relationship (r = −0.5) between SUVmax and ADCmin was observed in tumors with a spatial match (D ≤ 12 mm). In conclusion, spatial mismatch between ADCmin and SUVmax is found in a considerable percentage of patients. The spatial connection of the two parameters SUVmax and ADCmin has a crucial influence on their numeric correlation. PMID:29391862
Sauter, Alexander W; Stieltjes, Bram; Weikert, Thomas; Gatidis, Sergios; Wiese, Mark; Klarhöfer, Markus; Wild, Damian; Lardinois, Didier; Bremerich, Jens; Sommer, Gregor
2017-01-01
The minimum apparent diffusion coefficient (ADC min ) derived from diffusion-weighted MRI (DW-MRI) and the maximum standardized uptake value (SUV max ) of FDG-PET are markers of aggressiveness in lung cancer. The numeric correlation of the two parameters has been extensively studied, but their spatial interplay is not well understood. After FDG-PET and DW-MRI coregistration, values and location of ADC min - and SUV max -voxels were analyzed. The upper limit of the 95% confidence interval for registration accuracy of sequential PET/MRI was 12 mm, and the mean distance ( D ) between ADC min - and SUV max -voxels was 14.0 mm (average of two readers). Spatial mismatch ( D > 12 mm) between ADC min and SUV max was found in 9/25 patients. A considerable number of mismatch cases (65%) was also seen in a control group that underwent simultaneous PET/MRI. In the entire patient cohort, no statistically significant correlation between SUV max and ADC min was seen, while a moderate negative linear relationship ( r = -0.5) between SUV max and ADC min was observed in tumors with a spatial match ( D ≤ 12 mm). In conclusion, spatial mismatch between ADC min and SUV max is found in a considerable percentage of patients. The spatial connection of the two parameters SUV max and ADC min has a crucial influence on their numeric correlation.
NASA Astrophysics Data System (ADS)
Kuwahara, Ken; Higashiiu, Shinya; Ito, Daisuke; Koyama, Shigeru
This paper deals with the experimental study on cooling heat transfer of supercritical carbon dioxide inside micro-fin tubes. The geometrical parameters in micro-fin tubes used in the present study are 6.02 mm in outer diameter, 4.76 mm to 5.11 mm in average inner diameter, 0.15 mm to 0.24 mm in fin height, 5 to 25 in helix angle, 46 to 52 in number of fins and 1.4 to 2.3 in area expansion ratio. Heat transfer coefficients were measured at 8-10 MPa in pressure, 360-690 kg/(m2•s) in mass velocity and 20-75 °C in CO2 temperature. The measured heat transfer coefficients of micro-fin tubes were 1.4 to 2 times higher than those of the smooth tube having 4.42 in inner diameter. The predicted heat transfer coefficients using the correlation equation, which was developed for single-phase turbulent fluid flow inside micro-fin-tubes, showed large deviations to the measured values. The new correlation to predict cooling heat transfer coefficient of supercritical carbon dioxide inside micro-fin tubes was developed taking into account the shape of fins based on experimental data empirically. This correlation equation agreed within ±20% of almost all of the experimental data.
Rathbun, R.E.; Tai, D.Y.
1988-01-01
The two-film model is often used to describe the volatilization of organic substances from water. This model assumes uniformly mixed water and air phases separated by thin films of water and air in which mass transfer is by molecular diffusion. Mass-transfer coefficients for the films, commonly called film coefficients, are related through the Henry's law constant and the model equation to the overall mass-transfer coefficient for volatilization. The films are modeled as two resistances in series, resulting in additive resistances. The two-film model and the concept of additivity of resistances were applied to experimental data for acetone and t-butyl alcohol. Overall mass-transfer coefficients for the volatilization of acetone and t-butyl alcohol from water were measured in the laboratory in a stirred constant-temperature bath. Measurements were completed for six water temperatures, each at three water mixing conditions. Wind-speed was constant at about 0.1 meter per second for all experiments. Oxygen absorption coefficients were measured simultaneously with the measurement of the acetone and t-butyl alcohol mass-transfer coefficients. Gas-film coefficients for acetone, t-butyl alcohol, and water were determined by measuring the volatilization fluxes of the pure substances over a range of temperatures. Henry's law constants were estimated from data from the literature. The combination of high resistance in the gas film for solutes with low values of the Henry's law constants has not been studied previously. Calculation of the liquid-film coefficients for acetone and t-butyl alcohol from measured overall mass-transfer and gas-film coefficients, estimated Henry's law constants, and the two-film model equation resulted in physically unrealistic, negative liquid-film coefficients for most of the experiments at the medium and high water mixing conditions. An analysis of the two-film model equation showed that when the percentage resistance in the gas film is large and the gas-film resistance approaches the overall resistance in value, the calculated liquid-film coefficient becomes extremely sensitive to errors in the Henry's law constant. The negative coefficients were attributed to this sensitivity and to errors in the estimated Henry's law constants. Liquid-film coefficients for the absorption of oxygen were correlated with the stirrer Reynolds number and the Schmidt number. Application of this correlation with the experimental conditions and a molecular-diffusion coefficient adjustment resulted in values of the liquid-film coefficients for both acetone and t-butyl alcohol within the range expected for all three mixing conditions. Comparison of Henry's law constants calculated from these film coefficients and the experimental data with the constants calculated from literature data showed that the differences were small relative to the errors reported in the literature as typical for the measurement or estimation of Henry's law constants for hydrophilic compounds such as ketones and alcohols. Temperature dependence of the mass-transfer coefficients was expressed in two forms. The first, based on thermodynamics, assumed the coefficients varied as the exponential of the reciprocal absolute temperature. The second empirical approach assumed the coefficients varied as the exponential of the absolute temperature. Both of these forms predicted the temperature dependence of the experimental mass-transfer coefficients with little error for most of the water temperature range likely to be found in streams and rivers. Liquid-film and gas-film coefficients for acetone and t-butyl alcohol were similar in value. However, depending on water mixing conditions, overall mass-transfer coefficients for acetone were from two to four times larger than the coefficients for t-butyl alcohol. This difference in behavior of the coefficients resulted because the Henry's law constant for acetone was about three times larger than that of
[Culture and quality of life assessment in Chinese populations].
Xia, Ping; Li, Ning-Xiu; Liu, Chao-Jie; Lü, Yu-Bo; Zhang, Qiang; Ou, Ai-Hua
2010-07-01
To investigate the impact of cultural factors on quality of life (QOL) and to identify appropriate ways of dividing sub-populations for population norm-based quality of life assessment. The WHOQOL-BREF was used as a QOL instrument. Another questionnaire was developed to assess cultural values. A cross-sectional survey was undertaken in 1090 Guangzhou residents, which included 635 respondents from communities and 455 patients who visited outpatient departments of hospitals. Cronbach's a coefficients and item-domain correlation coefficients were calculated to test the reliability and validity of the WHOQOL-BREF, respectively. Student t test, ANOVA and stepwise multiple linear regression analysis were performed to identify the variables that might have an impact on the QOL. Two regression models with and without including cultural variables were constructed, and the extent of impact exerted by the cultural factors was assessed through a comparison of the change of adjusted R square values. A total of 1052 (96%) valid questionnaire were returned. The Cronbach's alpha coefficients of the WHOQOL-BREF ranged from 0.67 to 0.78. Age, education, occupation and family income were correlated with all of the domains of the WHOQOL-BREF. Chronic condition was correlated with physical, psychological, and social relationship domains of the WHOQOL-BREF. Gender was correlated with physical and psychological domains of the WHOQOL-BREF. The multiple regression analysis showed that social and demographic factors contributed to 6.3%, 13.6%, 10.4% and 8.7% of the predicted variances for the physical, psychological, social relationship, and environment domains, respectively. Social support, horizontal collectivism, vertical individualism, escape acceptance, fear of death, health value, supernatural belief had a significant impact on QOL. However, social support was the only one factor that had an impact on all of the four QOL domains. It is necessary to divide sub-cultural populations for population norm-based QOL assessment. Further research is needed to develop a practical approach to the sub-cultural population division.
A Study to Determine the Optimal Frequency for Conducting Periodic Dental Examinations (OFDEX)
1980-06-01
as the major vehicle by which patients enter into the incremental care system . Unpublished data from studies performed by the Health Care Studies...product-moment correlation was used to measure the strength of the relationship between two variables. Significance tests for correlation coefficients...expected if no relationship existed between variables at given row and column totals. These expected frequencies are then compared to the actual values
Investigations of the Quantum Correlation in Two-Qubit Heisenberg XYZ Model with Decoherence
NASA Astrophysics Data System (ADS)
Guo-Hui, Yang
2017-03-01
Quantum correlation dynamics in an anisotropic Heisenberg XYZ model under decoherence is investigated with the use of concurrence C and quantum discord (QD). With the Werner state as the initial state, we discuss the influence of mixture degree r on the dynamics. There are some difference between the time evolution behaviors of these two correlation measures with different value of r. For 0 ≤ r ≤ 1/3, there exists quantum discord but no entanglement; For 1/3< r<1, there is a "entanglement sudden death and birth" phenomenon in the concurrence but not in the QD; For r=1, there is one interesting thing that the concurrence decays from 1 to a minimum value close to 0 but the QD vanish. In addition, we have investigated the influence of different parameters on the two correlation measures. It has been found that, the concurrence and QD both exhibit osillatory behaviors with the time evolution, which is independent on the magnetic field B and the coupling coefficient J z . However, the Dzyaloshinskii-Moriya interaction (D) and coupling coefficient J have strong influence on concurrence and QD. With the increasing of the D or J, the frequency of the oscillation getting larger. When time is fixed, with the increasing of D or J, the concurrence and QD change periodically.
Ikram, Najmul; Qadir, Muhammad Abdul; Afzal, Muhammad Tanvir
2018-01-01
Sequence similarity is a commonly used measure to compare proteins. With the increasing use of ontologies, semantic (function) similarity is getting importance. The correlation between these measures has been applied in the evaluation of new semantic similarity methods, and in protein function prediction. In this research, we investigate the relationship between the two similarity methods. The results suggest absence of a strong correlation between sequence and semantic similarities. There is a large number of proteins with low sequence similarity and high semantic similarity. We observe that Pearson's correlation coefficient is not sufficient to explain the nature of this relationship. Interestingly, the term semantic similarity values above 0 and below 1 do not seem to play a role in improving the correlation. That is, the correlation coefficient depends only on the number of common GO terms in proteins under comparison, and the semantic similarity measurement method does not influence it. Semantic similarity and sequence similarity have a distinct behavior. These findings are of significant effect for future works on protein comparison, and will help understand the semantic similarity between proteins in a better way.
Han, Xu; Suo, Shiteng; Sun, Yawen; Zu, Jinyan; Qu, Jianxun; Zhou, Yan; Chen, Zengai; Xu, Jianrong
2017-03-01
To compare four methods of region-of-interest (ROI) placement for apparent diffusion coefficient (ADC) measurements in distinguishing low-grade gliomas (LGGs) from high-grade gliomas (HGGs). Two independent readers measured ADC parameters using four ROI methods (single-slice [single-round, five-round and freehand] and whole-volume) on 43 patients (20 LGGs, 23 HGGs) who had undergone 3.0 Tesla diffusion-weighted imaging and time required for each method of ADC measurements was recorded. Intraclass correlation coefficients (ICCs) were used to assess interobserver variability of ADC measurements. Mean and minimum ADC values and time required were compared using paired Student's t-tests. All ADC parameters (mean/minimum ADC values of three single-slice methods, mean/minimum/standard deviation/skewness/kurtosis/the10 th and 25 th percentiles/median/maximum of whole-volume method) were correlated with tumor grade (low versus high) by unpaired Student's t-tests. Discriminative ability was determined by receiver operating characteristic curves. All ADC measurements except minimum, skewness, and kurtosis of whole-volume ROI differed significantly between LGGs and HGGs (all P < 0.05). Mean ADC value of single-round ROI had the highest effect size (0.72) and the greatest areas under the curve (0.872). Three single-slice methods had good to excellent ICCs (0.67-0.89) and the whole-volume method fair to excellent ICCs (0.32-0.96). Minimum ADC values differed significantly between whole-volume and single-round ROI (P = 0.003) and, between whole-volume and five-round ROI (P = 0.001). The whole-volume method took significantly longer than all single-slice methods (all P < 0.001). ADC measurements are influenced by ROI determination methods. Whole-volume histogram analysis did not yield better results than single-slice methods and took longer. Mean ADC value derived from single-round ROI is the most optimal parameter for differentiating LGGs from HGGs. 3 J. Magn. Reson. Imaging 2017;45:722-730. © 2016 International Society for Magnetic Resonance in Medicine.
Judging in Rhythmic Gymnastics at Different Levels of Performance.
Leandro, Catarina; Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta
2017-12-01
This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach's alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges' difficulty scores, the Kendall's coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach's alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level.
Judging in Rhythmic Gymnastics at Different Levels of Performance
Ávila-Carvalho, Lurdes; Sierra-Palmeiro, Elena; Bobo-Arce, Marta
2017-01-01
Abstract This study aimed to analyse the quality of difficulty judging in rhythmic gymnastics, at different levels of performance. The sample consisted of 1152 difficulty scores concerning 288 individual routines, performed in the World Championships in 2013. The data were analysed using the mean absolute judge deviation from the final difficulty score, a Cronbach’s alpha coefficient and intra-class correlations, for consistency and reliability assessment. For validity assessment, mean deviations of judges’ difficulty scores, the Kendall’s coefficient of concordance W and ANOVA eta-squared values were calculated. Overall, the results in terms of consistency (Cronbach’s alpha mostly above 0.90) and reliability (intra-class correlations for single and average measures above 0.70 and 0.90, respectively) were satisfactory, in the first and third parts of the ranking on all apparatus. The medium level gymnasts, those in the second part of the ranking, had inferior reliability indices and highest score dispersion. In this part, the minimum of corrected item-total correlation of individual judges was 0.55, with most values well below, and the matrix for between-judge correlations identified remarkable inferior correlations. These findings suggest that the quality of difficulty judging in rhythmic gymnastics may be compromised at certain levels of performance. In future, special attention should be paid to the judging analysis of the medium level gymnasts, as well as the Code of Points applicability at this level. PMID:29339996
NASA Astrophysics Data System (ADS)
Lizarraga, Ion; Bou-Ali, M. Mounir; Santamaría, C.
2018-03-01
In this study, the thermodiffusion coefficient of n-dodecane/n-hexane binary mixture at 25 ∘C mean temperature was determined for several pressure conditions and mass fractions. The experimental technique used to determine the thermodiffusion coefficient was the thermograviational column of cylindrical configuration. In turn, thermophysical properties, such as density, thermal expansion, mass expansion and dynamic viscosity up to 10 MPa were also determined. The results obtained in this work showed a linear relation between the thermophysical properties and the pressure. Thermodiffusion coefficient values confirm a linear effect when the pressure increases. Additionally, a new correlation based on the thermodiffusion coefficient for n C12/n C6 binary mixture at 25 ∘C temperature for any mass fraction and pressures, which reproduces the data within the experimental error, was proposed.
NASA Astrophysics Data System (ADS)
Suciu, N.; Vamos, C.; Vereecken, H.; Vanderborght, J.; Hardelauf, H.
2003-04-01
When the small scale transport is modeled by a Wiener process and the large scale heterogeneity by a random velocity field, the effective coefficients, Deff, can be decomposed as sums between the local coefficient, D, a contribution of the random advection, Dadv, and a contribution of the randomness of the trajectory of plume center of mass, Dcm: Deff=D+Dadv-Dcm. The coefficient Dadv is similar to that introduced by Taylor in 1921, and more recent works associate it with the thermodynamic equilibrium. The ``ergodic hypothesis'' says that over large time intervals Dcm vanishes and the effect of the heterogeneity is described by Dadv=Deff-D. In this work we investigate numerically the long time behavior of the effective coefficients as well as the validity of the ergodic hypothesis. The transport in every realization of the velocity field is modeled with the Global Random Walk Algorithm, which is able to track as many particles as necessary to achieve a statistically reliable simulation of the process. Averages over realizations are further used to estimate mean coefficients and standard deviations. In order to remain in the frame of most of the theoretical approaches, the velocity field was generated in a linear approximation and the logarithm of the hydraulic conductivity was taken to be exponential decaying correlated with variance equal to 0.1. Our results show that even in these idealized conditions, the effective coefficients tend to asymptotic constant values only when the plume travels thousands of correlations lengths (while the first order theories usually predict Fickian behavior after tens of correlations lengths) and that the ergodicity conditions are still far from being met.
Bauer, Katharina Christin; Hämmerling, Frank; Kittelmann, Jörg; Dürr, Cathrin; Görlich, Fabian; Hubbuch, Jürgen
2017-04-01
Information about protein-protein interactions provides valuable knowledge about the phase behavior of protein solutions during the biopharmaceutical production process. Up to date it is possible to capture their overall impact by an experimentally determined potential of mean force. For the description of this potential, the second virial coefficient B22, the diffusion interaction parameter kD, the storage modulus G', or the diffusion coefficient D is applied. In silico methods do not only have the potential to predict these parameters, but also to provide deeper understanding of the molecular origin of the protein-protein interactions by correlating the data to the protein's three-dimensional structure. This methodology furthermore allows a lower sample consumption and less experimental effort. Of all in silico methods, QSAR modeling, which correlates the properties of the molecule's structure with the experimental behavior, seems to be particularly suitable for this purpose. To verify this, the study reported here dealt with the determination of a QSAR model for the diffusion coefficient of proteins. This model consisted of diffusion coefficients for six different model proteins at various pH values and NaCl concentrations. The generated QSAR model showed a good correlation between experimental and predicted data with a coefficient of determination R2 = 0.9 and a good predictability for an external test set with R2 = 0.91. The information about the properties affecting protein-protein interactions present in solution was in agreement with experiment and theory. Furthermore, the model was able to give a more detailed picture of the protein properties influencing the diffusion coefficient and the acting protein-protein interactions. Biotechnol. Bioeng. 2017;114: 821-831. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Koyama, Tetsuo; Marumoto, Kohei; Miyake, Hiroji; Domen, Kazuhisa
2013-11-01
This study examined the relationship between fractional anisotropy (FA) values of magnetic resonance-diffusion tensor imaging (DTI) and motor outcome (1 month after onset) in 15 patients with hemiparesis after ischemic stroke of corona radiata lesions. DTI data were obtained on days 14-18. FA values within the cerebral peduncle were analyzed using a computer-automated method. Motor outcome of hemiparesis was evaluated according to Brunnstrom stage (BRS; 6-point scale: severe to normal) for separate shoulder/elbow/forearm, wrist/hand, and lower extremity functions. The ratio of FA values in the affected hemisphere to those in the unaffected hemisphere (rFA) was assessed in relation to the BRS data (Spearman rank correlation test, P<.05). rFA values ranged from .715 to 1.002 (median=.924). BRS ranged from 1 to 6 (median=4) for shoulder/elbow/forearm, from 1 to 6 (median=5) for wrist/hand, and from 2 to 6 (median=4) for the lower extremities. Analysis revealed statistically significant relationships between rFA and upper extremity functions (correlation coefficient=.679 for shoulder/elbow/forearm and .706 for wrist/hand). Although slightly less evident, the relationship between rFA and lower extremity function was also statistically significant (correlation coefficient=.641). FA values within the cerebral peduncle are moderately associated with the outcome of both upper and lower extremity functions, suggesting that DTI may be applicable for outcome prediction in stroke patients with corona radiata infarct. Copyright © 2013 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Damage extraction of buildings in the 2015 Gorkha, Nepal earthquake from high-resolution SAR data
NASA Astrophysics Data System (ADS)
Yamazaki, Fumio; Bahri, Rendy; Liu, Wen; Sasagawa, Tadashi
2016-05-01
Satellite remote sensing is recognized as one of the effective tools for detecting and monitoring affected areas due to natural disasters. Since SAR sensors can capture images not only at daytime but also at nighttime and under cloud-cover conditions, they are especially useful at an emergency response period. In this study, multi-temporal high-resolution TerraSAR-X images were used for damage inspection of the Kathmandu area, which was severely affected by the April 25, 2015 Gorkha Earthquake. The SAR images obtained before and after the earthquake were utilized for calculating the difference and correlation coefficient of backscatter. The affected areas were identified by high values of the absolute difference and low values of the correlation coefficient. The post-event high-resolution optical satellite images were employed as ground truth data to verify our results. Although it was difficult to estimate the damage levels for individual buildings, the high resolution SAR images could illustrate their capability in detecting collapsed buildings at emergency response times.
Labocha, Marta K.; Sadowska, Edyta T.; Baliga, Katarzyna; Semer, Aleksandra K.; Koteja, Paweł
2004-01-01
Basal metabolic rate (BMR) is a fundamental energetic trait and has been measured in hundreds of birds and mammals. Nevertheless, little is known about the consistency of the population-average BMR or its repeatability at the level of individual variation. Here, we report that average mass-independent BMR did not differ between two generations of bank voles or between two trials separated by one month. Individual differences in BMR were highly repeatable across the one month interval: the coefficient of intraclass correlation was 0.70 for absolute log-transformed values and 0.56 for mass-independent values. Thus, BMR can be a meaningful measure of an individual physiological characteristic and can be used to test hypotheses concerning relationships between BMR and other traits. On the other hand, mass-independent BMR did not differ significantly across families, and the coefficient of intraclass correlation for full sibs did not differ from zero, which suggests that heritability of BMR in voles is not high. PMID:15101695
Study of V-OTDR stability for dynamic strain measurement in piezoelectric vibration
NASA Astrophysics Data System (ADS)
Ren, Meiqi; Lu, Ping; Chen, Liang; Bao, Xiaoyi
2016-09-01
In a phase-sensitive optical-time domain reflectometry (Φ-OTDR) system, the challenge for dynamic strain measurement lies in large intensity fluctuations from trace to trace. The intensity fluctuation caused by stochastic characteristics of Rayleigh backscattering sets detection limit for the minimum strength of vibration measurement and causes the large measurement uncertainty. Thus, a trace-to-trace correlation coefficient is introduced to quantify intensity fluctuation of Φ-OTDR traces and stability of the sensor system theoretically and experimentally. A novel approach of measuring dynamic strain induced by various driving voltages of lead zirconate titanate (PZT) in Φ-OTDR is also demonstrated. Piezoelectric vibration signals are evaluated through analyzing peak values of fast Fourier transform spectra at the fundamental frequency and high-order harmonics based on Bessel functions. High trace-to-trace correlation coefficients varying from 0.824 to 0.967 among 100 measurements are obtained in experimental results, showing the good stability of our sensor system, as well as small uncertainty of measured peak values.
NASA Astrophysics Data System (ADS)
Rock, N. M. S.; Duffy, T. R.
REGRES allows a range of regression equations to be calculated for paired sets of data values in which both variables are subject to error (i.e. neither is the "independent" variable). Nonparametric regressions, based on medians of all possible pairwise slopes and intercepts, are treated in detail. Estimated slopes and intercepts are output, along with confidence limits, Spearman and Kendall rank correlation coefficients. Outliers can be rejected with user-determined stringency. Parametric regressions can be calculated for any value of λ (the ratio of the variances of the random errors for y and x)—including: (1) major axis ( λ = 1); (2) reduced major axis ( λ = variance of y/variance of x); (3) Y on Xλ = infinity; or (4) X on Y ( λ = 0) solutions. Pearson linear correlation coefficients also are output. REGRES provides an alternative to conventional isochron assessment techniques where bivariate normal errors cannot be assumed, or weighting methods are inappropriate.
[Landscape quality evaluation and vertical structure optimization of natural broadleaf forest].
Ouyang, Xun-zhi; Liao, Wei-ming; Peng, Shi-kui
2007-06-01
Taking the natural broadleaf forest in Wuyuan County of Jiangxi Province as study object, a total of 30 representative photos of near-view landscapes and related information were collected. The scenic beauty values were acquired by public judgment method, and the relationship models of scenic beauty values and landscape elements were established by using multiple mathematical model. The results showed that the main elements affecting the near-view landscape quality of natural broadleaf forest were the trunk form, stand density, undergrowth coverage and height, natural pruning, and color richness, with the partial correlation coefficients being 0.4482-0.7724, which were significant or very significant by t-test. The multiple correlation coefficient of the model reached 0.9508, showing very significant by F test (F = 36.11). Straight trunk, better natural pruning and rich color did well, while the super-high or low stand density and undergrowth coverage and height did harm to the scenic beauty. Several management measures for the vertical structure optimization of these landscape elements were put forward.
Cathepsin D in normal and neoplastic thyroid tissues.
Kraimps, J L; Métayé, T; Millet, C; Margerit, D; Ingrand, P; Goujon, J M; Levillain, P; Babin, P; Begon, F; Barbier, J
1995-12-01
Cathepsin D is a widely distributed lysosomal acidic endopeptidase. It is an estrogen-regulated protein that is a prognostic factor in breast cancer. The aim of this study was to measure cathepsin D concentrations in thyroid tissues and to correlate these concentrations with clinical and pathologic parameters. Cathepsin D and thyroglobulin concentrations were measured in the cytosol of normal thyroid tissues (n = 14), benign nodules (n = 6), and thyroid carcinomas (n = 32) with an immunoradiometric assay. Statistical analysis was based on the Kruskal-Wallis and Wilcoxon tests and on the Spearman rank correlation coefficient. The mean level of cathepsin D, expressed as picomoles per milligram protein minus thyroglobulin, was higher in the 32 carcinomas, 29.1 +/- 15.5, than in the 14 normal thyroid tissues, 8.4 +/- 2.5 (p < 0.001) or in the 6 benign nodules, 11.2 +/- 7.3 (p = 0.003). Cathepsin D concentrations correlated with tumor size; Spearman rank correlation coefficient was rs = 0.44 (p = 0.012). No significant difference was found regarding histologic type. Cathepsin D concentrations were inversely correlated with the thyroglobulin level in the tumor; Spearman rank correlation coefficient was rs = -0.60 (p < 0.001). Cathepsin D concentration is higher in thyroid carcinoma than in normal thyroid tissue. Increased cathepsin D concentrations correlate with thyroid tumor size but not with histologic type. Further studies should be done to confirm the potential prognostic value of cathepsin D in patients with thyroid carcinomas.
[Analysis on the relationship between malaria epidemics and NOAA-AVHRR NDVI in Hainan province].
Wen, Liang; Xu, De-zhong; Wang, Shan-qing; Li, Cai-xu; Zhang, Zhi-ying; Su, Yong-qiang
2005-04-01
To explore the relationship between malaria epidemics and NOAA-AVHRR NDVI. Data on malaria were collected in all 19 counties in Hainan province from Feb, 1995 to Jan, 1996. Values regarding normalized difference vegetation index (NDVI)-related indicators including mean and maximum values of NDVI, the area proportion of NDVI values of 145- and 145+, months with NDVI values of 135+, 140+, 145+, 150+ of these counties in this period were all extracted from NOAA-AVHRR images, using ERDAS8.5 software. The coefficients of correlation of malaria incidences and these NDVI-related indicator values were then calculated with SPSS 11.0. The incidence of malaria showed positive correlations to mean and maximum values of NDVI, the area proportion of NDVI values of 145+ and months with NDVI values of 135+, 140+, 145+, 150+ respectively, but having negative correlation to the area of NDVI values of 145-. The malaria epidemic regions were in accordance with those regions that the NDVI values of 145+ were continuing for 9 months or more. Malaria prevalence was associated with NOAA-AVHRR NDVI value which could be considered to be use for malaria surveillance in Hainan province.
[Validating the Spanish version of the Nursing Activities Score].
Sánchez-Sánchez, M M; Arias-Rivera, S; Fraile-Gamo, M P; Thuissard-Vasallo, I J; Frutos-Vivar, F
2015-01-01
Validating workload scores ensures that they are appropriate for the purpose for which they were developed. To validate the Nursing Activities Score (NAS) Spanish version. Observational and prospective study. 1,045 patients who were admitted to a medical-surgical unit and a serious burns unit in 2006 were included. The nurse in charge assessed patient workloads by Nine Equivalent of Nursing Manpower use Score and NAS. To assess the internal consistency of the measurements of NAS, item-test correlations, Cronbach's α and Cronbach's α corrected by omitting each of the items were calculated. The intraobserver and interobserver reliability were assessed with the intraclass correlation coefficient by viewing recordings and Kappa (interobserver reliability) was estimated. For the analysis of internal validity, a factorial principal components analysis was performed. Convergent validity was assessed using the Spearman correlation coefficient values obtained from the Nine Equivalent of Nursing Manpower use Score and Spanish-NAS scales. For internal consistency, 164 questionnaires were analysed and a Cronbach's α of 0.373 was calculated. The intraclass correlation coefficient for intraobserver reliability estimate was 0.837 (95% IC: 0.466-0.950) and 0.662 (95% IC: 0.033-0.882) for interobserver reliability. The estimated kappa was 0.371. For internal validity, exploratory factor analysis showed that the first item explained 58.9% of the variance of the questionnaire. For convergent validity 1006 questionnaires were included and a Spearman correlation coefficient of 0.746 was observed. The psychometric properties of Spanish-NAS are acceptable. Copyright © 2014 Elsevier España, S.L.U. y SEEIUC. All rights reserved.
Analysis of Correlation Tendency between Wind and Solar from Various Spatio-temporal Perspectives
NASA Astrophysics Data System (ADS)
Wang, X.; Weihua, X.; Mei, Y.
2017-12-01
Analysis of correlation between wind resources and solar resources could explore their complementary features, enhance the utilization efficiency of renewable energy and further alleviate the carbon emission issues caused by the fossil energy. In this paper, we discuss the correlation between wind and solar from various spatio-temporal perspectives (from east to west, in terms of plain, plateau, hill, and mountain, from hourly to daily, ten days and monthly) with observed data and modeled data from NOAA (National Oceanic and Atmospheric Administration) and NERL (National Renewable Energy Laboratory). With investigation of wind speed time series and solar radiation time series (period: 10 years, resolution: 1h) of 72 stations located in various landform and distributed dispersedly in USA, the results show that the correlation coefficient, Kendall's rank correlation coefficient, changes negative to positive value from east coast to west coast of USA, and this phenomena become more obvious when the time scale of resolution increases from daily to ten days and monthly. Furthermore, considering the differences of landforms which influence the local meteorology the Kendall coefficients of diverse topographies are compared and it is found that the coefficients descend from mountain to hill, plateau and plain. However, no such evident tendencies could be found in daily scale. According to this research, it is proposed that the complementary feature of wind resources and solar resources in the east or in the mountain area of USA is conspicuous. Subsequent study would try to further verify this analysis by investigating the operation status of wind power station and solar power station.
NASA Astrophysics Data System (ADS)
Sang, Y. F.; Xie, P.; Ziyi, W.; Jiangyan, Z.; Qianjin, D.; Xu, L.
2017-12-01
As a significant manifestation of hydrological variability, abrupt change will obviously impact on the water security. To analyze what does the variation bring under changing environment, abrupt change detection should be a basic task, as well as variation level evaluation and hydrological frequency analysis. However, there lacks an effective method to reach those purposes systematically. Here we derived correlation coefficient between the original series and the jump-component series which is related to the difference degree of mean value before and after the abrupt change. Based on it, we proposed the moving-correlation-coefficient-based detection method and evaluated the significance of abrupt change as different levels related to the value of correlation coefficient. Then, with the obtained results, we calculated hydrological frequency in different situation (before and after the abrupt change). The approach above was employed to investigate the transboundary runoff of Lanstang-Mekong River at some kinds of time scale. We obtained the abrupt changes from runoff series of year, flood season and dry season which are almost the same. All the abrupt changes were significant which could reach to the moderate level. Compared with the past situation (before the abrupt change), the hydrological frequency in the current situation (after the abrupt change) indicated the water security of the water supply and flood control in the lower reaches of Lanstang-Mekong River could be guaranteed better, which is owed to the construction and operation of the water conservancy projects on the upper Lanstang-Mekong River.
Balci, N Cem; Momtahen, Amir Javad; Akduman, E Isin; Alkaade, Samer; Bilgin, Mehmet; Burton, Frank R
2008-10-01
To evaluate the correlation between apparent diffusion coefficient (ADC) values of the pancreas on diffusion-weighted imaging (DWI) and pancreatic exocrine function determined by HCO(3) concentration in the secretin endoscopic pancreatic function test (ePFT). Mean ADC values derived from 10 different points of the pancreatic gland on DWI were reviewed in 14 patients with normal (peak HCO(3) > or = 80 mEq/L) and 14 patients with abnormal (peak HCO(3) < 80 mEq/L) ePFT results. Magnetic resonance cholangiopancreatography (MRCP) images of the same patients were evaluated for the diagnosis of chronic pancreatitis. Correlation between ADC values and HCO(3) concentration as well as Cambridge scores in MRCP was performed using Spearman's correlation test. Mean ADC value of the pancreas was 1.52 +/- 0.13 x 10(-3) mm(2)/s in patients with abnormal ePFT results and 1.78 +/- 0.07 x 10(-3) mm(2)/s in the normal group. There was a significant statistical difference between the ADC values of the pancreas in the two groups (P < .0001). There was also a statistically significant correlation between HCO(3) level and ADC value of the pancreas in the study patients (r = 0.771, P < .0001). Morphologic changes of the pancreas according to the Cambridge classification were also well correlated with the mean ADC values (r = -0.763, P < .0001). Strong correlation between ADC value and pancreatic exocrine function as well as Cambridge score for chronic pancreatitis exists. Further studies are needed to determine the cut off ADC value for chronic pancreatitis.
Solar Terrestrial Influences on the D Region as Shown by the Level of Atmospheric Radio Noise
NASA Technical Reports Server (NTRS)
Satori, G.; Schaning, B.
1984-01-01
Measurements of the integrated atmospheric radio noise field strength at 27 kHz, used here, were made from 1965 to 1975 at Uppsala, Kuhlungsborn, and Prague-Panska Ves. The large scale meteorological situation was considered by comparing solar disturbed and undisturbed periods under similar weather situations. In order to show the effects of the precipitating high energy particle (HEP) flux and of the Forbush decrease on the noise level between pairs of stations were computed as deviations from the monthly median. Delta E (dB), day by day for all six periods was studied. The correlation coefficients for noon as well as for night values were computed. The correlation coefficients were compared with those for solar undisturbed periods.
Determination of suitable drying curve model for bread moisture loss during baking
NASA Astrophysics Data System (ADS)
Soleimani Pour-Damanab, A. R.; Jafary, A.; Rafiee, S.
2013-03-01
This study presents mathematical modelling of bread moisture loss or drying during baking in a conventional bread baking process. In order to estimate and select the appropriate moisture loss curve equation, 11 different models, semi-theoretical and empirical, were applied to the experimental data and compared according to their correlation coefficients, chi-squared test and root mean square error which were predicted by nonlinear regression analysis. Consequently, of all the drying models, a Page model was selected as the best one, according to the correlation coefficients, chi-squared test, and root mean square error values and its simplicity. Mean absolute estimation error of the proposed model by linear regression analysis for natural and forced convection modes was 2.43, 4.74%, respectively.
Sharma, Mukesh C; Sharma, S
2016-12-01
A series of 2-dihydro-4-quinazolin with potent highly selective inhibitors of inducible nitric oxide synthase activities was subjected to quantitative structure activity relationships (QSAR) analysis. Statistically significant equations with high correlation coefficient (r 2 = 0.8219) were developed. The k-nearest neighbor model has showed good cross-validated correlation coefficient and external validation values of 0.7866 and 0.7133, respectively. The selected electrostatic field descriptors the presence of blue ball around R1 and R4 in the quinazolinamine moiety showed electronegative groups favorable for nitric oxide synthase activity. The QSAR models may lead to the structural requirements of inducible nitric oxide compounds and help in the design of new compounds.
Fell, Matthew; Meirte, Jill; Anthonissen, Mieke; Maertens, Koen; Pleat, Jonathon; Moortgat, Peter
2016-03-01
Objective scar assessment tools were designed to help identify problematic scars and direct clinical management. Their use has been restricted by their measurement of a single scar property and the bulky size of equipment. The Scarbase Duo(®) was designed to assess both trans-epidermal water loss (TEWL) and colour of a burn scar whilst being compact and easy to use. Twenty patients with a burn scar were recruited and measurements taken using the Scarbase Duo(®) by two observers. The Scarbase Duo(®) measures TEWL via an open-chamber system and undertakes colorimetry via narrow-band spectrophotometry, producing values for relative erythema and melanin pigmentation. Validity was assessed by comparing the Scarbase Duo(®) against the Dermalab(®) and the Minolta Chromameter(®) respectively for TEWL and colorimetry measurements. The intra-class correlation coefficient (ICC) was used to assess reliability with standard error of measurement (SEM) used to assess reproducibility of measurements. The Pearson correlation coefficient (r) was used to assess the convergent validity. The Scarbase Duo(®) TEWL mode had excellent reliability when used on scars for both intra- (ICC=0.95) and inter-rater (ICC=0.96) measurements with moderate SEM values. The erythema component of the colorimetry mode showed good reliability for use on scars for both intra-(ICC=0.81) and inter-rater (ICC=0.83) measurements with low SEM values. Pigmentation values showed excellent reliability on scar tissue for both intra- (ICC=0.97) and inter-rater (ICC=0.97) with moderate SEM values. The Scarbase Duo(®) TEWL function had excellent correlation with the Dermalab(®) (r=0.93) whilst the colorimetry erythema value had moderate correlation with the Minolta Chromameter (r=0.72). The Scarbase Duo(®) is a reliable and objective scar assessment tool, which is specifically designed for burn scars. However, for clinical use, standardised measurement conditions are recommended. Copyright © 2015 Elsevier Ltd and ISBI. All rights reserved.
Structure dependence of the rate coefficients of hydroxyl radical+aromatic molecule reaction
NASA Astrophysics Data System (ADS)
Wojnárovits, László; Takács, Erzsébet
2013-06-01
The rate coefficients of hydroxyl radical addition to the rings of simple aromatic molecules (kOH) were evaluated based on the literature data. By analyzing the methods of kOH determination and the data obtained the most probable values were selected for the kOH's of individual compounds and thereby the most reliable dataset was created for monosubstituted aromatics and p-substituted phenols. For these compounds the rate coefficients fall in a narrow range between 2×109 mol-1 dm3 s-1 and 1×1010 mol-1 dm3 s-1. Although the values show some regular trend with the electron donating/withdrawing nature of the substituent, the log kOH-σp Hammett substituent constant plots do not give straight lines because these high kOH's are controlled by both, the chemical reactivity and the diffusion. However, the logarithms of the rate coefficients of the chemical reactivity controlled reactions (kchem), are calculated by the equation 1/kOH=1/kchem+1/kdiff, and accepting for the diffusion controlled rate coefficient kdiff=1.1×1010 mol-1 dm3 s-1, show good linear correlation with σp.
Impact of Autocorrelation on Functional Connectivity
Arbabshirani, Mohammad R.; Damaraju, Eswar; Phlypo, Ronald; Plis, Sergey; Allen, Elena; Ma, Sai; Mathalon, Daniel; Preda, Adrian; Vaidya, Jatin G.; Adali, Tülay; Calhoun, Vince D.
2014-01-01
Although the impact of serial correlation (autocorrelation) in residuals of general linear models for fMRI time-series has been studied extensively, the effect of autocorrelation on functional connectivity studies has been largely neglected until recently. Some recent studies based on results from economics have questioned the conventional estimation of functional connectivity and argue that not correcting for autocorrelation in fMRI time-series results in “spurious” correlation coefficients. In this paper, first we assess the effect of autocorrelation on Pearson correlation coefficient through theoretical approximation and simulation. Then we present this effect on real fMRI data. To our knowledge this is the first work comprehensively investigating the effect of autocorrelation on functional connectivity estimates. Our results show that although FC values are altered, even following correction for autocorrelation, results of hypothesis testing on FC values remain very similar to those before correction. In real data we show this is true for main effects and also for group difference testing between healthy controls and schizophrenia patients. We further discuss model order selection in the context of autoregressive processes, effects of frequency filtering and propose a preprocessing pipeline for connectivity studies. PMID:25072392
Lee, Jung-Ah; Oh, Yu-Ri; Hwang, Min-A; Lee, Joong-Bok; Park, Seung-Yong; Song, Chang-Seon; Choi, In-Soo; Lee, Sang-Won
2016-09-01
The porcine respiratory disease complex (PRDC) caused by numerous bacterial and viral agents has a great impact on pig industry worldwide. Although Mycoplasma hyorhinis (Mhr) has been frequently isolated from lung lesions from pigs with PRDC, the pathological importance of Mhr may have been underestimated. In this study, 383 serum samples obtained from seven herds with a history of PRDC were tested for specific antibodies to Mhr, Mycoplasma hyopneumoniae (Mhp), and porcine reproductive and respiratory syndrome virus (PRRSV). Seropositive rates of PRRSV were significantly correlated with those of Mhr (correlation coefficient, 0.862; P-value, 0.013), but not with those of Mhp (correlation coefficient, -0.555; P-value, 0.196). In vivo experiments demonstrated that pigs co-infected with Mhr and PRRSV induced more severe lung lesions than pigs infected with Mhr or PRRSV alone. These findings suggest that Mhr is closely associated with pneumonia caused by PRRSV and provide important information on Mhr pathogenesis within PRDC. Therefore, effective PRDC control strategies should also consider the potential impact of Mhr in the pathogenesis of PRDC. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nazhan, Salam; Ghassemlooy, Zabih; Busawon, Krishna
2016-01-15
In this paper, the influence of the rotating polarization-preserved optical feedback on the chaos synchronization of a vertical-cavity surface-emitting laser (VCSEL) is investigated experimentally. Two VCSELs' polarization modes (XP) and (YP) are gradually rotated and re-injected back into the VCSEL. The anti-phase dynamics synchronization of the two polarization modes is evaluated using the cross-correlation function. For a fixed optical feedback, a clear relationship is found between the cross-correlation coefficient and the polarization angle θ{sub p}. It is shown that high-quality anti-phase polarization-resolved chaos synchronization is achieved at higher values of θ{sub p}. The maximum value of the cross-correlation coefficient achievedmore » is −0.99 with a zero time delay over a wide range of θ{sub p} beyond 65° with a poor synchronization dynamic at θ{sub p} less than 65°. Furthermore, it is observed that the antiphase irregular oscillation of the XP and YP modes changes with θ{sub p}. VCSEL under the rotating polarization optical feedback can be a good candidate as a chaotic synchronization source for a secure communication system.« less
Assessment of body parameters' symmetry in child violinists.
Cygańska, Anna; Truszczyńska-Baszak, Aleksandra; Drzał-Grabiec, Justyna; Tarnowski, Adam
2017-09-22
Playing violin may lead to overload of the locomotor system. The aim of this study was to assess body parameters for trunk symmetry in child violinists and compare with the control group. We analyzed body posture of 101 children aged 7-12 years, mean age 11.09 ± 9.46, 49 child violinists and control group of 52 children. We found statistically significant differences for the difference in depth of the lower corners of scapulae and upper posterior spina iliaca, though greater asymmetries were found in the clinical control group. The remaining parameter values are close to significance, which may suggest that the process of postural change among the children had just started and that the existing asymmetries were easy to correct. We found positive correlation between body height and the difference in distance of the lower corners of scapulae from the spine: OL (p= 0.029, correlation coefficient value was 0.167) and the Thales triangle height: (p= 0.018, correlation coefficient was 0.214). Position maintained while playing the violin changed some parameters characterizing the curvature of the spine in frontal plane. We found the importance of detailed analysis of children body posture and its critical assessment.
A new correlation coefficient for bivariate time-series data
NASA Astrophysics Data System (ADS)
Erdem, Orhan; Ceyhan, Elvan; Varli, Yusuf
2014-11-01
The correlation in time series has received considerable attention in the literature. Its use has attained an important role in the social sciences and finance. For example, pair trading in finance is concerned with the correlation between stock prices, returns, etc. In general, Pearson’s correlation coefficient is employed in these areas although it has many underlying assumptions which restrict its use. Here, we introduce a new correlation coefficient which takes into account the lag difference of data points. We investigate the properties of this new correlation coefficient. We demonstrate that it is more appropriate for showing the direction of the covariation of the two variables over time. We also compare the performance of the new correlation coefficient with Pearson’s correlation coefficient and Detrended Cross-Correlation Analysis (DCCA) via simulated examples.
Chen, Bin; Wu, Hong-yang; Han, Chao; Yan, Huan; Liu, Ge
2015-10-01
Trace water has a significant impact on the electrical performances of the insulating oil, such as the dielectric loss factor, resistivity. So there is an important significance to investigate the influence of insulating oil by trace water, and monitor its operating status with effective measures. First, it is necessary to prepare the insulating oil samples with different water content and treat them 8 hours with ultrasonic oscillator, and observe microscopic images about the water-oil mixtures in order to study their relative uniformity and stable time, in the way it can be concluded that the relative uniformity can be kept favorable during the 25 min stable time for free water and emulsification water in oil; Based on this conclusion, the dielectric loss factor, resistivity were tested and the electrical performances of insulating oil with different water content in oil can obtained by analyzing these data; Then, the absorbance value of the different water content in oil at the spectral wave number of 1 640, 3 400, 3 450, 3 615 cm(-1), with the mid-infrared spectral scanning and analyzing to the different water content in oil, Therefore, combined the water absorbance values by the mid-infrared spectral scanning and analyzing with the experimental data of dielectric loss factor value, resistivity value of oil samples. The results shows that the absorbance value of the different water content in oil has a significant difference at the spectral wave number of 1 640, 3 400, 3450, 3 615 cm(-1), their correlation coefficient are 0.964 1, 0.984 8, 0.984 5, 0.944 0 between the absorbance value and water content at the spectral wave number of 1 640, 3 400, 3 450, 3 615 cm(-1), it can be obtained that the absorbance value of sample of moisture in the corresponding characteristic wave number can better reflect the change trend of water content; there is the highly relative of water absorbance values at the spectral wave number of 3 400 and 3 450 cm(-1) with the trends of oil dielectric loss factor values, their correlation coefficient are 0.860 6, 0.863 6; and relative of water absorbance values at the spectral wave number of 1 640 and 3 615 cm(-1) with the trends of oil resistivity values, their correlation coefficient is -0.931 5 and -0.968 0, this result can be lay the foundation research for monitoring the trace water in oil.
Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio
2017-01-01
Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5))−18) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin’s concordance correlation coefficient, linear regression, Bland–Altman’s agreement analysis, concordance correlation coefficient (ρc) and the coefficient of determination (R2) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R2 = 0.384, p < 0.001. A paired-sample t-test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = −6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin’s concordance correlation coefficient was poor (ρc = 0.014, 95% CI = −0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels. PMID:28106719
Memory effects in funnel ratchet of self-propelled particles
NASA Astrophysics Data System (ADS)
Hu, Cai-Tian; Wu, Jian-Chun; Ai, Bao-Quan
2017-05-01
The transport of self-propelled particles with memory effects is investigated in a two-dimensional periodic channel. Funnel-shaped barriers are regularly arrayed in the channel. Due to the asymmetry of the barriers, the self-propelled particles can be rectified. It is found that the memory effects of the rotational diffusion can strongly affect the rectified transport. The memory effects do not always break the rectified transport, and there exists an optimal finite value of correlation time at which the rectified efficiency takes its maximal value. We also find that the optimal values of parameters (the self-propulsion speed, the translocation diffusion coefficient, the rotational noise intensity, and the self-rotational diffusion coefficient) can facilitate the rectified transport. When introducing a finite load, particles with different self-propulsion speeds move to different directions and can be separated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lorenz, Michael, E-mail: mlorenz@physik.uni-leipzig.de; Schwinkendorf, Peter; Grundmann, Marius
2015-01-05
Multiferroic (BaTiO{sub 3}-BiFeO{sub 3}) × 15 multilayer heterostructures show high magnetoelectric (ME) coefficients α{sub ME} up to 24 V/cm·Oe at 300 K. This value is much higher than that of a single-phase BiFeO{sub 3} reference film (α{sub ME} = 4.2 V/cm·Oe). We found clear correlation of ME coefficients with increasing oxygen partial pressure during growth. ME coupling is highest for lower density of oxygen vacancy-related defects. Detailed scanning transmission electron microscopy and selected area electron diffraction microstructural investigations at 300 K revealed antiphase rotations of the oxygen octahedra in the BaTiO{sub 3} single layers, which are an additional correlated defect structure of the multilayers.
Correlation of track irregularities and vehicle responses based on measured data
NASA Astrophysics Data System (ADS)
Karis, Tomas; Berg, Mats; Stichel, Sebastian; Li, Martin; Thomas, Dirk; Dirks, Babette
2018-06-01
Track geometry quality and dynamic vehicle response are closely related, but do not always correspond with each other in terms of maximum values and standard deviations. This can often be seen to give poor results in analyses with correlation coefficients or regression analysis. Measured data from both the EU project DynoTRAIN and the Swedish Green Train (Gröna Tåget) research programme is used in this paper to evaluate track-vehicle response for three vehicles. A single degree of freedom model is used as an inspiration to divide track-vehicle interaction into three parts, which are analysed in terms of correlation. One part, the vertical axle box acceleration divided by vehicle speed squared (?) and the second spatial derivative of the vertical track irregularities (?), is shown to be the weak link with lower correlation coefficients than the other parts. Future efforts should therefore be directed towards investigating the relation between axle box accelerations and track irregularity second derivatives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szabo, G.; Bulman, R.A.
The determination of soil adsorption coefficients (K[sub oc]) via HPLC capacity factors (k[prime]) has been studied, including the effect of column type and mobile phase composition on the correlation between log K[sub oc] and log k[prime]. K[sub oc] values obtained by procedures other than HPLC correlate well with HPLC capacity factors determined on a chemically immobilized humic acid stationary phase, and it is suggested that this phase is a better model for the sorption onto soil or sediment than the octadecyl-, phenyl- and ethylsilica phases. By using log k[prime][sub w] a theoretical capacity factor has been obtained by extrapolation ofmore » the retention data in a binary solvent system to pure aqueous eluent. There is a better correlation between log K[sub oc] and log k[prime][sub w] than the correlation between log K[sub oc] and log k[prime].« less
Çavuşoğlu, Berrin; Durak, Hatice
2011-01-01
Objective: Relation between patient age and Hounsfield Unit (HU),which is the linear attenuation coefficient, and Standardized Uptake Values (SUV) which is the amount of 18F-fluorodeoxyglucose (F-18 FDG) uptake, measured in the areas of interest drawn to prostate, seminal vesicles and testicles in F-18 FDG Positron Emission Tomography/Computed Tomography (PET/CT) images was investigated. Material and Methods: Mean and maximum SUV and HU values were recorded from the areas of interest (min 12 mm in diameter) which showed FDG uptake in prostate, seminal vesicles and testicles from F-18 FDG PET-CT images of 21 male patients under 40 years without genitourinary cancer. The effect of patient age to SUV and HU values was examined with Pearson correlation test using SPSS program. Results: There was a negative insignificant correlation between patient age and SUV and HU values for prostate. For seminal vesicles, correlation between patient age and SUV values and HUmax were positive but insignificant, while correlation with HUmean was significant (r=0.459, p=0.00). Correlation between patient age and SUVmax and SUVmean values were significant for testicles (r=0.506, p=0.002 and r=0.467, p=0.005, respectively) but the correlation between patient age and HUmax and HUmean values was not significant. Conclusion: F-18 FDG uptake in testicles in males increases with age until 40, suggesting an increase in metabolic rate. The significant correlation between age and mean HU values is probably caused by thickening of the tissue without an increase in glucose metabolism in seminal vesicles. In prostate, the effect of patient age to SUV and HU values was not observed until the age 40. Conflict of interest:None declared. PMID:23486855
Repeatability and reproducibility of corneal thickness using SOCT Copernicus HR.
Vidal, Silvia; Viqueira, Valentín; Mas, David; Domenech, Begoña
2013-05-01
The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (S(W)) and the within-subject coefficient of variation (C(W)). The level of agreement by Bland-Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Koziol, Liz; Bever, James D
2018-01-01
Abstract Many plant species are limited to habitats relatively unaffected by anthropogenic disturbance, so protecting these undisturbed habitats is essential for plant conservation. Coefficients of conservatism (C values) were developed as indicators of a species’ sensitivity to anthropogenic disturbance, and these values are used in Floristic Quality Assessment as a means of assessing natural areas and ecological restoration. However, assigning of these values is subjective and improved quantitative validation of C values is needed. We tested whether there are consistent differences in life histories between species with high and low C values. To do this, we grew 54 species of tallgrass prairie plants in a greenhouse and measured traits that are associated with trade-offs on the fast-slow continuum of life-history strategies. We also grew plants with and without mycorrhizal fungi as a test of these species’ reliance on this mutualism. We compared these traits and mycorrhizal responsiveness to C values. We found that six of the nine traits we measured were correlated with C values, and together, traits predicted up to 50 % of the variation in C values. Traits including fast growth rates and greater investment in reproduction were associated with lower C values, and slow growth rates, long-lived leaves and high root:shoot ratios were associated with higher C values. Additionally, plants with high C values and a slow life history were more responsive to mutualisms with mycorrhizal fungi. Overall, our results connect C values with life-history trade-offs, indicating that high C value species tend to share a suite of traits associated with a slow life history. PMID:29383232
Bauer, Jonathan T; Koziol, Liz; Bever, James D
2018-02-01
Many plant species are limited to habitats relatively unaffected by anthropogenic disturbance, so protecting these undisturbed habitats is essential for plant conservation. Coefficients of conservatism (C values) were developed as indicators of a species' sensitivity to anthropogenic disturbance, and these values are used in Floristic Quality Assessment as a means of assessing natural areas and ecological restoration. However, assigning of these values is subjective and improved quantitative validation of C values is needed. We tested whether there are consistent differences in life histories between species with high and low C values. To do this, we grew 54 species of tallgrass prairie plants in a greenhouse and measured traits that are associated with trade-offs on the fast-slow continuum of life-history strategies. We also grew plants with and without mycorrhizal fungi as a test of these species' reliance on this mutualism. We compared these traits and mycorrhizal responsiveness to C values. We found that six of the nine traits we measured were correlated with C values, and together, traits predicted up to 50 % of the variation in C values. Traits including fast growth rates and greater investment in reproduction were associated with lower C values, and slow growth rates, long-lived leaves and high root:shoot ratios were associated with higher C values. Additionally, plants with high C values and a slow life history were more responsive to mutualisms with mycorrhizal fungi. Overall, our results connect C values with life-history trade-offs, indicating that high C value species tend to share a suite of traits associated with a slow life history.
Scheduling on the basis of the research of dependences among the construction process parameters
NASA Astrophysics Data System (ADS)
Romanovich, Marina; Ermakov, Alexander; Mukhamedzhanova, Olga
2017-10-01
The dependences among the construction process parameters are investigated in the article: average integrated value of qualification of the shift, number of workers per shift and average daily amount of completed work on the basis of correlation coefficient are considered. Basic data for the research of dependences among the above-stated parameters have been collected during the construction of two standard objects A and B (monolithic houses), in four months of construction (October, November, December, January). Kobb-Douglas production function has proved the values of coefficients of correlation close to 1. Function is simple to be used and is ideal for the description of the considered dependences. The development function, describing communication among the considered parameters of the construction process, is developed. The function of the development gives the chance to select optimum quantitative and qualitative (qualification) structure of the brigade link for the work during the next period of time, according to a preset value of amount of works. Function of the optimized amounts of works, which reflects interrelation of key parameters of construction process, is developed. Values of function of the optimized amounts of works should be used as the average standard for scheduling of the storming periods of construction.
Correlation of second virial coefficient with solubility for proteins in salt solutions.
Mehta, Chirag M; White, Edward T; Litster, James D
2012-01-01
In this work, osmotic second virial coefficients (B(22)) were determined and correlated with the measured solubilities for the proteins, α-amylase, ovalbumin, and lysozyme. The B(22) values and solubilities were determined in similar solution conditions using two salts, sodium chloride and ammonium sulfate in an acidic pH range. An overall decrease in the solubility of the proteins (salting out) was observed at high concentrations of ammonium sulfate and sodium chloride solutions. However, for α-amylase, salting-in behavior was also observed in low concentration sodium chloride solutions. In ammonium sulfate solutions, the B(22) are small and close to zero below 2.4 M. As the ammonium sulfate concentrations were further increased, B(22) values decreased for all systems studied. The effect of sodium chloride on B(22) varies with concentration, solution pH, and the type of protein studied. Theoretical models show a reasonable fit to the experimental derived data of B(22) and solubility. B(22) is also directly proportional to the logarithm of the solubility values for individual proteins in salt solutions, so the log-linear empirical models developed in this work can also be used to rapidly predict solubility and B(22) values for given protein-salt systems. Copyright © 2011 American Institute of Chemical Engineers (AIChE).
NASA Astrophysics Data System (ADS)
Li, Wei; Shen, Guofeng; Yuan, Chenyi; Wang, Chen; Shen, Huizhong; Jiang, Huai; Zhang, Yanyan; Chen, Yuanchen; Su, Shu; Lin, Nan; Tao, Shu
2016-05-01
The gas/particle partitioning of nitro-polycyclic aromatic hydrocarbons (nPAHs) and oxy-PAHs (oPAHs) is pivotal to estimate their environmental fate. Simultaneously measured atmospheric concentrations of nPAHs and oPAHs in both gaseous and particulate phases at 18 sites in northern China make it possible to investigate their partitioning process in a large region. The gas/particle partitioning coefficients (Kp) in this study were higher than those measured in the emission exhausts. The Kp for most individual nPAHs was higher than those for their corresponding parent PAHs. Generally higher Kp values were found at rural field sites compared to values in the rural villages and cities. Temperature, subcooled liquid-vapor pressure (Pl0) and octanol-air partition coefficient (Koa) were all significantly correlated with Kp. The slope values between log Kp and log Pl0, ranging from - 0.54 to - 0.34, indicate that the equilibrium of gas/particle partitioning might not be reached, which could be also revealed from a positive correlation between log Kp and particulate matter (PM) concentrations. Underestimation commonly exists in all three partitioning models, but the predicted values of Kp from the dual model are closer to the measured Kp for derivative PAHs in northern China.
NASA Astrophysics Data System (ADS)
Purswell, Jerry L.; Schlegel, Robert E.
1988-06-01
When there is no simple or accurate procedure for measuring the coefficient of friction (COF) at a job site, workers and/or supervisors involved must make subjective judgments about the slipperiness of the walking and climbing surfaces and in turn decide whether the surface presents a safe or an unsafe condition for work. This project was designed to determine whether these subjective judgment calls did in fact agree with the COF measurements obtained using a mechanical device. It was noted that the coatings chosen for study were subject to a polishing factor by the boot soles during the trials, causing the COF values to become lower as the trials continued. Poor correlation was obtained between subjective ratings of slipperiness and the COF values measured before the trials began. A relatively high correlation was obtained between subjective ratings and the COF values measured after the trials had been completed. A difference was noted in the subjective ratings for the effects of water on a coating for column climbing, but not for walking a beam, suggesting the effects of water on a coating are related to the type of task being performed in steel erection. An increase in the measured COF was noted for all of the coatings when they were wet as compared to the dry condition. The importance of clean shoe soles was clearly demonstrated.
Yu, Xuejuan; Liu, Shangang; Chen, Zhaoqiu; Zhang, Pinliang; Zhang, Jianbo; Xu, Liang; Liu, Zengjun; Ren, Ruimei
2014-08-01
To study the correlation between the MRI apparent diffusion coefficient (ADC) value and histological grade and molecular biology of breast invasive ductal carcinoma (IDC). This retrospective study included 125 patients with IDC verified by pathology from February 2010 to February 2013. Conventional MRI and diffusion-weighted imaging (DWI) examination were performed using a 3.0T scanner with diffusion factor of 0 and 800 s/mm(2). The region of interest (ROI) was drawn on the largest lesion and/or its two adjacent slices. The ADC value of the whole tumor was calculated as the mean ADC value. The correlation between mean ADCs and histological grade and biological factors was analyzed. The mean ADC of pathological grade I, II and III IDC was (1.152 ± 0.072)×10(-3) mm(2)/s, (1.102 ± 0.101)×10(-3) mm(2)/s, and (1.035 ± 0.107)×10(-3) mm(2)/s, respectively. There was a statistically significant difference among them (P = 0.003). Statistically a significant difference was observed between grade III and I (P = 0.034), grade III and II (P = 0.006), but not between grade I and II (P = 0.741). A significant correlation was observed between ADC value and pathological grade (r = -0.342, P < 0.001). The median ADC values were significantly higher in the ER-negative than in the ER-positive cases [(1.130 ± 0.115)×10(-3) mm(2)/s vs. (1.060 ± 0.089) ×10(-3) mm(2)/s, P < 0.001)], in PR-negative than in PR-positive cases [(1.121 ± 0.106)×10(-3) mm(2)/s vs. (1.055 ± 0.096) ×10(-3) mm(2)/s, P < 0.001)], and in Ki-67-negative than in Ki-67-positive cases [(1.153 ± 0.090)×10(-3) mm(2)/s vs. (1.063 ± 0.101) ×10(-3) mm(2)/s, P < 0.001]. A statistically significant correlation was observed between ADC value and expressions of ER, PR, and Ki-67 (r = -0.311, r = -0.317, r = -0.414, P < 0.001). ADC value of breast invasive ductal carcinoma is correlated with histological grade, and expression of ER, PR and Ki-67.
Nguyen, T B; Cron, G O; Mercier, J F; Foottit, C; Torres, C H; Chakraborty, S; Woulfe, J; Jansen, G H; Caudrelier, J M; Sinclair, J; Hogan, M J; Thornhill, R E; Cameron, I G
2015-01-01
The prognostic value of dynamic contrast-enhanced MR imaging-derived plasma volume obtained in tumor and the contrast transfer coefficient has not been well-established in patients with gliomas. We determined whether plasma volume and contrast transfer coefficient in tumor correlated with survival in patients with gliomas in addition to other factors such as age, type of surgery, preoperative Karnofsky score, contrast enhancement, and histopathologic grade. This prospective study included 46 patients with a new pathologically confirmed diagnosis of glioma. The contrast transfer coefficient and plasma volume obtained in tumor maps were calculated directly from the signal-intensity curve without T1 measurements, and values were obtained from multiple small ROIs placed within tumors. Survival curve analysis was performed by dichotomizing patients into groups of high and low contrast transfer coefficient and plasma volume. Univariate analysis was performed by using dynamic contrast-enhanced parameters and clinical factors. Factors that were significant on univariate analysis were entered into multivariate analysis. For all patients with gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). In subgroups of high- and low-grade gliomas, survival was worse for groups of patients with high contrast transfer coefficient and plasma volume obtained in tumor (P < .05). Univariate analysis showed that factors associated with lower survival were age older than 50 years, low Karnofsky score, biopsy-only versus resection, marked contrast enhancement versus no/mild enhancement, high contrast transfer coefficient, and high plasma volume obtained in tumor (P < .05). In multivariate analysis, a low Karnofsky score, biopsy versus resection in combination with marked contrast enhancement, and a high contrast transfer coefficient were associated with lower survival rates (P < .05). In patients with glioma, those with a high contrast transfer coefficient have lower survival than those with low parameters. © 2015 by American Journal of Neuroradiology.
Diffusion coefficients of nitric oxide in water: A molecular dynamics study
NASA Astrophysics Data System (ADS)
Pokharel, Sunil; Pantha, Nurapati; Adhikari, N. P.
2016-09-01
Self-diffusion coefficients along with the mutual diffusion coefficients of nitric oxide (NO) and SPC/E water (H2O) as solute and solvent of the mixture, have been studied within the framework of classical molecular dynamics level of calculations using GROMACS package. The radial distribution function (RDF) of the constituent compounds are calculated to study solute-solute, solute-solvent and solvent-solvent molecular interactions as a function of temperature. A dilute solution of five NO molecules (mole fraction 0.018) and 280 H2O molecules (mole fraction 0.982) has been taken as the sample. The self-diffusion coefficient of the solvent is calculated by using mean square displacement (MSD) where as that for solute (NO) is calculated by using MSD and velocity auto-correlation function (VACF). The results are then compared with the available experimental values. The results from the present work for water come in good agreement, very precise at low temperatures, with the experimental values. The diffusion coefficients of NO, on the other hands, agree well with the available theoretical studies, and also with experiment at low temperatures (up to 310 K). The results at the higher temperatures (up to 333 K), however, deviate significantly with the experimental observations. Also, the mutual diffusion coefficients of NO in water have been calculated by using Darken’s relation. The temperature dependence of the calculated diffusion coefficients follow the Arrhenius behavior.
NASA Astrophysics Data System (ADS)
Song, Bo; Waldrop, Jonathan M.; Wang, Xiaopo; Patkowski, Konrad
2018-01-01
We have developed a new krypton-krypton interaction-induced isotropic dipole polarizability curve based on high-level ab initio methods. The determination was carried out using the coupled-cluster singles and doubles plus perturbative triples method with very large basis sets up to augmented correlation-consistent sextuple zeta as well as the corrections for core-core and core-valence correlation and relativistic effects. The analytical function of polarizability and our recently constructed reference interatomic potential [J. M. Waldrop et al., J. Chem. Phys. 142, 204307 (2015)] were used to predict the thermophysical and electromagnetic properties of krypton gas. The second pressure, acoustic, and dielectric virial coefficients were computed for the temperature range of 116 K-5000 K using classical statistical mechanics supplemented with high-order quantum corrections. The virial coefficients calculated were compared with the generally less precise available experimental data as well as with values computed from other potentials in the literature {in particular, the recent highly accurate potential of Jäger et al. [J. Chem. Phys. 144, 114304 (2016)]}. The detailed examination in this work suggests that the present theoretical prediction can be applied as reference values in disciplines involving thermophysical and electromagnetic properties of krypton gas.
A comparative study of monoclonal antibodies. 1. Phase behavior and protein-protein interactions
Lewus, Rachael A.; Levy, Nicholas E.; Lenhoff, Abraham M.; Sandler, Stanley I.
2018-01-01
Protein phase behavior is involved in numerous aspects of downstream processing, either by design as in crystallization or precipitation processes, or as an undesired effect, such as aggregation. This work explores the phase behavior of eight monoclonal antibodies (mAbs) that exhibit liquid-liquid separation, aggregation, gelation, and crystallization. The phase behavior has been studied systematically as a function of a number of factors, including solution composition and pH, in order to explore the degree of variability among different antibodies. Comparisons of the locations of phase boundaries show consistent trends as a function of solution composition; however, changing the solution pH has different effects on each of the antibodies studied. Furthermore, the types of dense phases formed varied among the antibodies. Protein-protein interactions, as reflected by values of the osmotic second virial coefficient, are used to correlate the phase behavior. The primary findings are that values of the osmotic second virial coefficient are useful for correlating phase boundary locations, though there is appreciable variability among the antibodies in the apparent strengths of the intrinsic protein-protein attraction manifested. However, the osmotic second virial coefficient does not provide a clear basis to predict the type of dense phase likely to result under a given set of solution conditions. PMID:25378269
Quantum-memory-assisted entropic uncertainty in spin models with Dzyaloshinskii-Moriya interaction
NASA Astrophysics Data System (ADS)
Huang, Zhiming
2018-02-01
In this article, we investigate the dynamics and correlations of quantum-memory-assisted entropic uncertainty, the tightness of the uncertainty, entanglement, quantum correlation and mixedness for various spin chain models with Dzyaloshinskii-Moriya (DM) interaction, including the XXZ model with DM interaction, the XY model with DM interaction and the Ising model with DM interaction. We find that the uncertainty grows to a stable value with growing temperature but reduces as the coupling coefficient, anisotropy parameter and DM values increase. It is found that the entropic uncertainty is closely correlated with the mixedness of the system. The increasing quantum correlation can result in a decrease in the uncertainty, and the robustness of quantum correlation is better than entanglement since entanglement means sudden birth and death. The tightness of the uncertainty drops to zero, apart from slight volatility as various parameters increase. Furthermore, we propose an effective approach to steering the uncertainty by weak measurement reversal.
Forecasting F10.7 with Solar Magnetic Flux Transport Modeling (Postprint)
2012-04-03
Charles N. Arge Joel B. Mozer Project Manager, RVBXS Chief, RVB This report is published in the interest of...within 6 hours of the F10.7 measurements during the years 1993 through 2010, the Spearman correlation coefficient, rs, for an empirical model of...estimation of the Earth-side solar magnetic field distribution used to forecast F10.7. Spearman correlation values of approximately 0.97, 0.95, and 0.93 are
Further Progress in Noise Source Identification in High Speed Jets via Causality Principle
NASA Technical Reports Server (NTRS)
Panda, J.; Seasholtz, R. G.; Elam, K. A.
2004-01-01
To locate noise sources in high-speed jets, the sound pressure fluctuations p/, measured at far field locations, were correlated with each of density p, axial velocity u, radial velocity v, puu and pvv fluctuations measured from various points in fully expanded, unheated plumes of Mach number 0.95, 1.4 and 1.8. The velocity and density fluctuations were measured simultaneously using a recently developed, non-intrusive, point measurement technique based on molecular Rayleigh scattering (Seasholtz, Panda, and Elam, AIAA Paper 2002-0827). The technique uses a continuous wave, narrow line-width laser, Fabry-Perot interferometer and photon counting electronics. The far field sound pressure fluctuations at 30 to the jet axis provided the highest correlation coefficients with all flow variables. The correlation coefficients decreased sharply with increased microphone polar angle, and beyond about 60 all correlation mostly fell below the experimental noise floor. Among all correlations < puu; p/> showed the highest values. Interestingly,
, in all respects, were very similar toBredow, J; Oppermann, J; Scheyerer, M J; Gundlfinger, K; Neiss, W F; Budde, S; Floerkemeier, T; Eysel, P; Beyer, F
2015-05-01
Radiological study. To asses standard values, intra- and interobserver reliability and reproducibility of sacral slope (SS) and lumbar lordosis (LL) and the correlation of these parameters in patients with lumbar spinal stenosis (LSS). Anteroposterior and lateral X-rays of the lumbar spine of 102 patients with LSS were included in this retrospective, radiologic study. Measurements of SS and LL were carried out by five examiners. Intraobserver correlation and correlation between LL and SS were calculated with Pearson's r linear correlation coefficient and intraclass correlation coefficients (ICC) were calculated for inter- and intraobserver reliability. In addition, patients were examined in subgroups with respect to previous surgery and the current therapy. Lumbar lordosis averaged 45.6° (range 2.5°-74.9°; SD 14.2°), intraobserver correlation was between Pearson r = 0.93 and 0.98. The measurement of SS averaged 35.3° (range 13.8°-66.9°; SD 9.6°), intraobserver correlation was between Pearson r = 0.89 and 0.96. Intraobserver reliability ranged from 0.966 to 0.992 ICC in LL measurements and 0.944-0.983 ICC in SS measurements. There was an interobserver reliability ICC of 0.944 in LL and 0.990 in SS. Correlation between LL and SS averaged r = 0.79. No statistically significant differences were observed between the analyzed subgroups. Manual measurement of LL and SS in patients with LSS on lateral radiographs is easily performed with excellent intra- and interobserver reliability. Correlation between LL and SS is very high. Differences between patients with and without previous decompression were not statistically significant.
Tests of Hypotheses Arising In the Correlated Random Coefficient Model*
Heckman, James J.; Schmierer, Daniel
2010-01-01
This paper examines the correlated random coefficient model. It extends the analysis of Swamy (1971), who pioneered the uncorrelated random coefficient model in economics. We develop the properties of the correlated random coefficient model and derive a new representation of the variance of the instrumental variable estimator for that model. We develop tests of the validity of the correlated random coefficient model against the null hypothesis of the uncorrelated random coefficient model. PMID:21170148
Yang, Fen; Wang, Meng; Wang, Zunyao
2013-09-01
This work studies the sorption behaviors of phthalic acid esters (PAEs) on three soils by batch equilibration experiments and quantitative structure property relationship (QSPR) methodology. Firstly, the effects of soil type, dissolved organic matter and pH on the sorption of four PAEs (DMP, DEP, DAP, DBP) are investigated. The results indicate that the soil organic carbon content has a crucial influence on sorption progress. In addition, a negative correlation between pH values and the sorption capacities was found for these four PAEs. However, the effect of DOM on PAEs sorption may be more complicated. The sorption of four PAEs was promoted by low concentrations of DOM, while, in the case of high concentrations, the influence of DOM on the sorption was complicated. Then the organic carbon content normalized sorption coefficient (logKoc) values of 17 PAEs on three soils were measured, and the mean values ranged from 1.50 to 7.57. The logKoc values showed good correlation with the corresponding logKow values. Finally, two QSPR models were developed with 13 theoretical parameters to get reliable logKoc predictions. The leave-one-out cross validation (CV-LOO) indicated that the internal predictive power of the two models was satisfactory. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Effects of polishing on surface roughness, gloss, and color of resin composites.
Hosoya, Yumiko; Shiraishi, Takanobu; Odatsu, Tetsuro; Nagafuji, Junichi; Kotaku, Mayumi; Miyazaki, Masashi; Powers, John M
2011-09-01
This study evaluated the effects of polishing on surface roughness, gloss, and color of regular, opaque, and enamel shades for each of three resin composites. Two-mm-thick resin disks made with Estelite Σ Quick, Clearfil Majesty, and Beautifil II were final polished with 180-, 1000-, and 3000-grit silicon carbide paper. Surface roughness, gloss, and color were measured one week after curing. Estelite Σ Quick had significantly lower roughness values and significantly higher gloss values as compared with Clearfil Majesty and Beautifil II. The effects of surface roughness and gloss on color (L*a*b*) differed among resin composites and by shade. Correlation coefficients between surface roughness and L*a*b* color factors were generally high for Clearfil Majesty, partially high (i.e., between roughness and L*) for Beautifil II, and low for Estelite Σ Quick. Correlation coefficients between gloss and L*a*b* color parameters were generally high for Beautifil II and low for Estelite Σ Quick and Clearfil Majesty. However, for all resin composites, the values of the color differences between 3000-grit and 180-grit polishing groups for all shades were imperceptible by the naked eye.
Segura-Correa, J C; Domínguez-Díaz, D; Avalos-Ramírez, R; Argaez-Sosa, J
2010-09-01
Knowledge of the intraherd correlation coefficient (ICC) and design (D) effect for infectious diseases could be of interest in sample size calculation and to provide the correct standard errors of prevalence estimates in cluster or two-stage samplings surveys. Information on 813 animals from 48 non-vaccinated cow-calf herds from North-eastern Mexico was used. The ICC for the bovine viral diarrhoea (BVD), infectious bovine rhinotracheitis (IBR), leptospirosis and neosporosis diseases were calculated using a Bayesian approach adjusting for the sensitivity and specificity of the diagnostic tests. The ICC and D values for BVD, IBR, leptospirosis and neosporosis were 0.31 and 5.91, 0.18 and 3.88, 0.22 and 4.53, and 0.11 and 2.68, respectively. The ICC and D values were different from 0 and D greater than 1, therefore large sample sizes are required to obtain the same precision in prevalence estimates than for a random simple sampling design. The report of ICC and D values is of great help in planning and designing two-stage sampling studies. 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Das Bhowmik, R.; Arumugam, S.
2015-12-01
Multivariate downscaling techniques exhibited superiority over univariate regression schemes in terms of preserving cross-correlations between multiple variables- precipitation and temperature - from GCMs. This study focuses on two aspects: (a) develop an analytical solutions on estimating biases in cross-correlations from univariate downscaling approaches and (b) quantify the uncertainty in land-surface states and fluxes due to biases in cross-correlations in downscaled climate forcings. Both these aspects are evaluated using climate forcings available from both historical climate simulations and CMIP5 hindcasts over the entire US. The analytical solution basically relates the univariate regression parameters, co-efficient of determination of regression and the co-variance ratio between GCM and downscaled values. The analytical solutions are compared with the downscaled univariate forcings by choosing the desired p-value (Type-1 error) in preserving the observed cross-correlation. . For quantifying the impacts of biases on cross-correlation on estimating streamflow and groundwater, we corrupt the downscaled climate forcings with different cross-correlation structure.
Wu, X; Reinikainen, P; Vanhanen, A; Kapanen, M; Vierikko, T; Ryymin, P; Hyödynmaa, S; Kellokumpu-Lehtinen, P-L
2017-01-01
To investigate whether diffusion-weighted imaging (DWI) apparent diffusion coefficient (ADC) correlates with prostate cancer aggressiveness and further to compare the diagnostic performance of ADC and normalized ADC (nADC: normalized to non-tumor tissue). Thirty pre-treatment patients (mean age, 69years; range: 59-78years) with prostate cancer underwent magnetic resonance imaging (MRI) examination, including DWI with three b values: 50, 400, and 800s/mm 2 . Both ADC and nADC were correlated with the Gleason score obtained through transrectal ultrasound-guided biopsy. The tumor minimum ADC (ADC min : the lowest ADC value within tumor) had an inverse correlation with the Gleason score (r=-0.43, P<0.05), and it was lower in patients with Gleason score 3+4 than in those with Gleason score 3+3 (0.54±0.11×10 3 mm 2 /s vs. 0.64±0.12×10 -3 mm 2 /s, P<0.05). Both the nADC min and nADC mean correlated with the Gleason score (r=-0.52 and r=-0.55, P<0.01; respectively), and they were lower in patients with Gleason score 3+4 than those with Gleason score 3+3 (P<0.01; respectively). Receiver operating characteristic (ROC) analysis showed that the area under the ROC curve was 0.765, 0.818, or 0.833 for the ADC min , nADC min , or nADC mean ; respectively, in differentiating between Gleason score 3+4 and 3+3 tumors. Tumor ADC min , nADC min , and nADC mean are useful markers to predict the aggressiveness of prostate cancer. Copyright © 2016 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Xinying, Li; Yongfang, Zhao; Xiaogong, Jing; Fengli, Liu; Fengyou, Hao
2006-01-01
We present the rules of electron correlation energies for RgX (Rg = Kr, Xe, X = Br, I) van der Waals (vdW) complex systems at CCSD(T) theoretical level with SDB-cc-pVQZ basis set by the Gaussian 98 program. A new method to derive the dispersion coefficient C6 by fitting the intermonomer electron correlation energies to C6R-6 function is introduced. The present C6 values are compared with the corresponding theoretical ones.
Badran, Darwish H; Kalbouneh, Heba M; Al-Hadidi, Maher T; Shatarat, Amjad T; Tarawneh, Emad S; Hadidy, Azmy M; Mahafza, Waleed S
2015-08-01
To estimate normal linear dimensions and volume of spleen in Jordanians using ultrasonography, and to correlate splenic volume with age and body parameters: height, weight, body surface area (BSA), and body mass index (BMI). A prospective pilot study was conducted on 205 volunteers (115 males and 90 females) not known to have any conditions likely to be associated with splenomegaly. The study was performed at the Radiology Department, Jordanian University Hospital, Amman, Jordan, between December 2013 and August 2014. All linear dimensions of spleen were measured, and splenic volume (index) was calculated using the standard prolate ellipsoid formula (length × width × depth × 0.523). The splenic volume was then analyzed with age and body parameters using the Pearson's correlation coefficient. The mean (± SD) splenic dimensions were 10.72±1.37 cm in length, 7.40±1.52 cm in width, 4.40±1.47 cm in depth, and 184.15±79.56 cm3 in volume. Men had larger spleens than women (p less than 0.0001). Age had no significant effect on spleen volume (r=0.11, p=0.12). There was a significant moderate positive correlation (p less than 0.0001), using Pearson's correlation coefficient, between the spleen volume, and other parameters (height, weight, BSA, and BMI), with correlation coefficients exceeding 0.3. A local reference of spleen dimensions was established with a different range of values reported previously.
A satellite snow depth multi-year average derived from SSM/I for the high latitude regions
Biancamaria, S.; Mognard, N.M.; Boone, A.; Grippa, M.; Josberger, E.G.
2008-01-01
The hydrological cycle for high latitude regions is inherently linked with the seasonal snowpack. Thus, accurately monitoring the snow depth and the associated aerial coverage are critical issues for monitoring the global climate system. Passive microwave satellite measurements provide an optimal means to monitor the snowpack over the arctic region. While the temporal evolution of snow extent can be observed globally from microwave radiometers, the determination of the corresponding snow depth is more difficult. A dynamic algorithm that accounts for the dependence of the microwave scattering on the snow grain size has been developed to estimate snow depth from Special Sensor Microwave/Imager (SSM/I) brightness temperatures and was validated over the U.S. Great Plains and Western Siberia. The purpose of this study is to assess the dynamic algorithm performance over the entire high latitude (land) region by computing a snow depth multi-year field for the time period 1987-1995. This multi-year average is compared to the Global Soil Wetness Project-Phase2 (GSWP2) snow depth computed from several state-of-the-art land surface schemes and averaged over the same time period. The multi-year average obtained by the dynamic algorithm is in good agreement with the GSWP2 snow depth field (the correlation coefficient for January is 0.55). The static algorithm, which assumes a constant snow grain size in space and time does not correlate with the GSWP2 snow depth field (the correlation coefficient with GSWP2 data for January is - 0.03), but exhibits a very high anti-correlation with the NCEP average January air temperature field (correlation coefficient - 0.77), the deepest satellite snow pack being located in the coldest regions, where the snow grain size may be significantly larger than the average value used in the static algorithm. The dynamic algorithm performs better over Eurasia (with a correlation coefficient with GSWP2 snow depth equal to 0.65) than over North America (where the correlation coefficient decreases to 0.29). ?? 2007 Elsevier Inc. All rights reserved.
Precision islands in the Ising and O(N ) models
Kos, Filip; Poland, David; Simmons-Duffin, David; ...
2016-08-04
We make precise determinations of the leading scaling dimensions and operator product expansion (OPE) coefficients in the 3d Ising, O(2), and O(3) models from the conformal bootstrap with mixed correlators. We improve on previous studies by scanning over possible relative values of the leading OPE coefficients, which incorporates the physical information that there is only a single operator at a given scaling dimension. The scaling dimensions and OPE coefficients obtained for the 3d Ising model, (Δ σ , Δ ϵ , λ σσϵ , λ ϵϵϵ ) = (0.5181489(10), 1.412625(10), 1.0518537(41), 1.532435(19) , give the most precise determinations of thesemore » quantities to date.« less
Novel priming and crosslinking systems for use with isocyanatomethacrylate dental adhesives.
Chappelow, C C; Power, M D; Bowles, C Q; Miller, R G; Pinzino, C S; Eick, J D
2000-11-01
(a) to design, formulate and evaluate prototype primers and a crosslinking agent for use with isocyanatomethacrylate-based comonomer adhesives and (b) to establish correlations between bond strength and solubility parameter differences between the adhesives and etched dentin, and the permeability coefficients of the adhesives. Equimolar mixtures of 2-isocyanatoethyl methacrylate (IEM) and a methacrylate comonomer were formulated with tri-n-butyl borane oxide (TBBO) as the free radical initiator to have cure times of 6-10 min. Shear bond strengths to dentin were determined for each adhesive mixture (n = 7) using standard testing protocols. Shear bond strengths for the three systems were also determined after application of "reactive primers" to the dentin surface. The "reactive primers" contained 10-20 parts by weight of the respective comonomer mixture and 3.5 parts by weight TBBO in acetone. Solubility parameters difference values (delta delta) and permeability coefficients (P) were approximated for each adhesive system and correlated with shear bond strength values. Additionally, a crosslinking agent was prepared by bulk reaction of an equimolar mixture containing IEM and a methacrylate comonomer. The effects of crosslinker addition on: (a) the setting time of IEM; and (b) the setting times and initiator requirements of selected IEM/comonomer mixtures were determined. Shear bond strength values (MPa): IEM/HEMA 13.6 +/- 2.0 (no primer), 20.1 +/- 2.0 (with primer); IEM/HETMA 9.3 +/- 3.3 (no primer), 20.8 +/- 8.1 (with primer); IEM/AAEMA 13.6 +/- 1.9 (no primer), 17.3 +/- 3.2 (with primer). Also, approximated permeability coefficients showed a significant correlation (r = +0.867, p < 0.001) with shear bond strength values. Crosslinker addition studies with IEM/4-META: (a) at 5-9 mol% reduced the setting time of IEM polymerization by 79%; and (b) at 6 mol% reduced initiator level requirements 60-70% to achieve a comparable setting time, and decreased setting times by ca. 75% for a given initiator level with selected IEM/methacrylate adhesive systems. The shear bond strengths of isocyanatomethacrylate-based dental adhesives can be enhanced by using reactive primers; their setting times and initiator requirements can be improved using a dimethacrylate crosslinker. Approximated permeability coefficients may be useful as indicators of bonding performance for dentin adhesive systems.
Zhao, Gao-feng; Zhang, Qiang; Pang, Yan; Ren, Zheng-jia; Peng, Dan; Jiang, Guo-guo; Liu, Shan-ming; Chen, Ying; Geng, Ting; Zhang, Shu-sen; Yang, Yan-chun; Deng, Hong
2009-11-01
To explore the reliability and validity of the Children's Impact of Event Scale (Chinese version, CRIES-13) and to determine the value and the optimal cutoff point of the score of CRIES-13 in screening posttraumatic stress disorder (PTSD), so as to provide evidence for PTSD prevention and identify children at risk in Wenchuan earthquake areas. A total of 253 children experienced the Wenchuan earthquake were tested through Stratified random cluster sampling. The authors examined CRIES-13's internal consistency, discriminative validity and predictive value of the cut-off. PTSD was assessed with the DSM-IV criteria. Area under the curve while sensitivity, specificity and Youden index were computed based on the receiver operating characteristic curve analysis. Optimal cutoff point was determined by the maximum of Youden index. 20.9% of the subjects were found to have met the DSM-IV criteria for PTSD 7 months after the Wenchuan earthquake accident. The Cronbach's coefficient of CRIES-13 was 0.903 and the mean inter-item correlation coefficients ranged from 0.283 to 0.689, the correlation coefficient of the three factors with the total scale scores ranged from 0.836 to 0.868 while the correlation coefficient among the three factors ranged from 0.568 to 0.718, PTSD cases indicated much higher scores than non-PTSD cases, the Youden index reached maximum value when the total score approached 18 in CRIES-13 with sensitivity and specificity as 81.1% and 76.5% respectively. Consistency check showed that there were no significant differences between the results of CRIES-13 score >/= 32 and clinical diagnosis (Kappa = 0.529) from the screening program. CRIES-13 appeared to be a reliable and valid measure for assessing the posttraumatic stress symptoms among children after the earthquake accident in the Wenchuan area. The CRIES-13 seemed to be a useful self-rating diagnostic instrument for survivors with PTSD symptoms as a clinical concern by using a 18 cut-off in total score. Consistency check showed that there was no significant difference between the screening result of CRIES-13 score >/= 32 and clinical diagnosis.
Response functions for computing absorbed dose to skeletal tissues from neutron irradiation
NASA Astrophysics Data System (ADS)
Bahadori, Amir A.; Johnson, Perry; Jokisch, Derek W.; Eckerman, Keith F.; Bolch, Wesley E.
2011-11-01
Spongiosa in the adult human skeleton consists of three tissues—active marrow (AM), inactive marrow (IM) and trabecularized mineral bone (TB). AM is considered to be the target tissue for assessment of both long-term leukemia risk and acute marrow toxicity following radiation exposure. The total shallow marrow (TM50), defined as all tissues lying within the first 50 µm of the bone surfaces, is considered to be the radiation target tissue of relevance for radiogenic bone cancer induction. For irradiation by sources external to the body, kerma to homogeneous spongiosa has been used as a surrogate for absorbed dose to both of these tissues, as direct dose calculations are not possible using computational phantoms with homogenized spongiosa. Recent micro-CT imaging of a 40 year old male cadaver has allowed for the accurate modeling of the fine microscopic structure of spongiosa in many regions of the adult skeleton (Hough et al 2011 Phys. Med. Biol. 56 2309-46). This microstructure, along with associated masses and tissue compositions, was used to compute specific absorbed fraction (SAF) values for protons originating in axial and appendicular bone sites (Jokisch et al 2011 Phys. Med. Biol. 56 6857-72). These proton SAFs, bone masses, tissue compositions and proton production cross sections, were subsequently used to construct neutron dose-response functions (DRFs) for both AM and TM50 targets in each bone of the reference adult male. Kerma conditions were assumed for other resultant charged particles. For comparison, AM, TM50 and spongiosa kerma coefficients were also calculated. At low incident neutron energies, AM kerma coefficients for neutrons correlate well with values of the AM DRF, while total marrow (TM) kerma coefficients correlate well with values of the TM50 DRF. At high incident neutron energies, all kerma coefficients and DRFs tend to converge as charged-particle equilibrium is established across the bone site. In the range of 10 eV to 100 MeV, substantial differences are observed among the kerma coefficients and DRF. As a result, it is recommended that the AM kerma coefficient be used to estimate the AM DRF, and that the TM kerma coefficient be used to estimate the TM50 DRF below 10 eV. Between 10 eV and 100 MeV, the appropriate DRF should be used as presented in this study. Above 100 MeV, spongiosa kerma coefficients apply well for estimating skeletal tissue doses. DRF values for each bone site as a function of energy are provided in an electronic annex to this article available at http://stacks.iop.org/0031-9155/56/6873/mmedia.
Response functions for computing absorbed dose to skeletal tissues from neutron irradiation.
Bahadori, Amir A; Johnson, Perry; Jokisch, Derek W; Eckerman, Keith F; Bolch, Wesley E
2011-11-07
Spongiosa in the adult human skeleton consists of three tissues-active marrow (AM), inactive marrow (IM) and trabecularized mineral bone (TB). AM is considered to be the target tissue for assessment of both long-term leukemia risk and acute marrow toxicity following radiation exposure. The total shallow marrow (TM(50)), defined as all tissues lying within the first 50 µm of the bone surfaces, is considered to be the radiation target tissue of relevance for radiogenic bone cancer induction. For irradiation by sources external to the body, kerma to homogeneous spongiosa has been used as a surrogate for absorbed dose to both of these tissues, as direct dose calculations are not possible using computational phantoms with homogenized spongiosa. Recent micro-CT imaging of a 40 year old male cadaver has allowed for the accurate modeling of the fine microscopic structure of spongiosa in many regions of the adult skeleton (Hough et al 2011 Phys. Med. Biol. 56 2309-46). This microstructure, along with associated masses and tissue compositions, was used to compute specific absorbed fraction (SAF) values for protons originating in axial and appendicular bone sites (Jokisch et al 2011 Phys. Med. Biol. 56 6857-72). These proton SAFs, bone masses, tissue compositions and proton production cross sections, were subsequently used to construct neutron dose-response functions (DRFs) for both AM and TM(50) targets in each bone of the reference adult male. Kerma conditions were assumed for other resultant charged particles. For comparison, AM, TM(50) and spongiosa kerma coefficients were also calculated. At low incident neutron energies, AM kerma coefficients for neutrons correlate well with values of the AM DRF, while total marrow (TM) kerma coefficients correlate well with values of the TM(50) DRF. At high incident neutron energies, all kerma coefficients and DRFs tend to converge as charged-particle equilibrium is established across the bone site. In the range of 10 eV to 100 MeV, substantial differences are observed among the kerma coefficients and DRF. As a result, it is recommended that the AM kerma coefficient be used to estimate the AM DRF, and that the TM kerma coefficient be used to estimate the TM(50) DRF below 10 eV. Between 10 eV and 100 MeV, the appropriate DRF should be used as presented in this study. Above 100 MeV, spongiosa kerma coefficients apply well for estimating skeletal tissue doses. DRF values for each bone site as a function of energy are provided in an electronic annex to this article available at http://stacks.iop.org/0031-9155/56/6873/mmedia.
Huang, Yecai; Huang, Jianming; Feng, Mei; Ren, Jing; Mi, Kun; Cheng, Jia; Song, Bing; Lang, Jinyi
2017-12-01
A cervical carcinoma allograft model was designed to assess the correlation between early changes in the apparent diffusion coefficient (ADC) values on diffusion-weighted magnetic resonance imaging (DW-MRI) and the expression of matrix metalloproteinase-9 (MMP-9) in tumors. BALB/c mice with U14 tumor allografts on the right rear flank were irradiated with a single 20 Gy dose. All tumor-bearing mice were subjected to DW-MRI, followed by calculation of the ADC values and characterization of the T1 and T2 relaxation time constants. Pre- and post-irradiation ADC values were compared with the tumor volume, and the immunohistochemical staining of MMP-9 and hematoxylin-eosin (HE) staining of tumor allografts. However, no correlations between the pre-treatment ADC values and changes in tumor volumes following irradiation were observed. Notably, the mean ADC value was significantly higher in the irradiated tumors (0.756±0.102×10 -3 mm 2 /sec) as compared with those in the untreated tumors (0.501±0.052×10 -3 mm 2 /sec; P=0.002; r=0.682). Additionally, immunohistochemical staining demonstrated that MMP-9 expression in the irradiated tumors was significantly increased. The mean ADC value was significantly higher in the irradiated tumors with high MMP-9 expression levels (0.815±0.112×10 -3 mm 2 /sec), as compared with in the untreated tumors with low MMP-9 expression levels (0.631±0.068×10 -3 mm 2 /sec). Quantitative analysis determined that the ADC values were correlated with MMP-9 expression (r=0.752; P=0.003). Combined, these results suggest that radiation-induced increases in MMP-9 expression levels may be responsible for early changes in the mean ADC value and the response to irradiation in cervical carcinoma.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harikrishnan, R.; Hareland, G.; Warpinski, N.R.
This paper evaluates the correlation between values of minimum principal in situ stress derived from two different models which use data obtained from triaxial core tests and coefficient for earth at rest correlations. Both models use triaxial laboratory tests with different confining pressures. The first method uses a vcrified fit to the Mohr failure envelope as a function of average rock grain size, which was obtained from detailed microscopic analyses. The second method uses the Mohr-Coulomb failure criterion. Both approaches give an angle in internal friction which is used to calculate the coefficient for earth at rest which gives themore » minimum principal in situ stress. The minimum principal in situ stress is then compared to actual field mini-frac test data which accurately determine the minimum principal in situ stress and are used to verify the accuracy of the correlations. The cores and the mini-frac stress test were obtained from two wells, the Gas Research Institute`s (GRIs) Staged Field Experiment (SFE) no. 1 well through the Travis Peak Formation in the East Texas Basin, and the Department of Energy`s (DOE`s) Multiwell Experiment (MWX) wells located west-southwest of the town of Rifle, Colorado, near the Rulison gas field. Results from this study indicates that the calculated minimum principal in situ stress values obtained by utilizing the rock failure envelope as a function of average rock grain size correlation are in better agreement with the measured stress values (from mini-frac tests) than those obtained utilizing Mohr-Coulomb failure criterion.« less
Zhao, Yu Xi; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi
2018-04-01
Hydrological process evaluation is temporal dependent. Hydrological time series including dependence components do not meet the data consistency assumption for hydrological computation. Both of those factors cause great difficulty for water researches. Given the existence of hydrological dependence variability, we proposed a correlationcoefficient-based method for significance evaluation of hydrological dependence based on auto-regression model. By calculating the correlation coefficient between the original series and its dependence component and selecting reasonable thresholds of correlation coefficient, this method divided significance degree of dependence into no variability, weak variability, mid variability, strong variability, and drastic variability. By deducing the relationship between correlation coefficient and auto-correlation coefficient in each order of series, we found that the correlation coefficient was mainly determined by the magnitude of auto-correlation coefficient from the 1 order to p order, which clarified the theoretical basis of this method. With the first-order and second-order auto-regression models as examples, the reasonability of the deduced formula was verified through Monte-Carlo experiments to classify the relationship between correlation coefficient and auto-correlation coefficient. This method was used to analyze three observed hydrological time series. The results indicated the coexistence of stochastic and dependence characteristics in hydrological process.
Higher harmonic flow coefficients of identified hadrons in Pb-Pb collisions at √{s_{NN}}=2.76 TeV
NASA Astrophysics Data System (ADS)
Adam, J.; Adamová, D.; Aggarwal, M. M.; Aglieri Rinella, G.; Agnello, M.; Agrawal, N.; Ahammed, Z.; Ahmad, S.; Ahn, S. U.; Aiola, S.; Akindinov, A.; Alam, S. N.; Albuquerque, D. S. D.; Aleksandrov, D.; Alessandro, B.; Alexandre, D.; Alfaro Molina, R.; Alici, A.; Alkin, A.; Alme, J.; Alt, T.; Altinpinar, S.; Altsybeev, I.; Alves Garcia Prado, C.; An, M.; Andrei, C.; Andrews, H. A.; Andronic, A.; Anguelov, V.; Antičić, T.; Antinori, F.; Antonioli, P.; Aphecetche, L.; Appelshäuser, H.; Arcelli, S.; Arnaldi, R.; Arnold, O. W.; Arsene, I. C.; Arslandok, M.; Audurier, B.; Augustinus, A.; Averbeck, R.; Azmi, M. D.; Badalà, A.; Baek, Y. W.; Bagnasco, S.; Bailhache, R.; Bala, R.; Balasubramanian, S.; Baldisseri, A.; Baral, R. C.; Barbano, A. M.; Barbera, R.; Barile, F.; Barnaföldi, G. G.; Barnby, L. S.; Barret, V.; Bartalini, P.; Barth, K.; Bartke, J.; Bartsch, E.; Basile, M.; Bastid, N.; Basu, S.; Bathen, B.; Batigne, G.; Batista Camejo, A.; Batyunya, B.; Batzing, P. C.; Bearden, I. G.; Beck, H.; Bedda, C.; Behera, N. K.; Belikov, I.; Bellini, F.; Bello Martinez, H.; Bellwied, R.; Belmont, R.; Belmont-Moreno, E.; Beltran, L. G. E.; Belyaev, V.; Bencedi, G.; Beole, S.; Berceanu, I.; Bercuci, A.; Berdnikov, Y.; Berenyi, D.; Bertens, R. A.; Berzano, D.; Betev, L.; Bhasin, A.; Bhat, I. R.; Bhati, A. K.; Bhattacharjee, B.; Bhom, J.; Bianchi, L.; Bianchi, N.; Bianchin, C.; Bielčík, J.; Bielčíková, J.; Bilandzic, A.; Biro, G.; Biswas, R.; Biswas, S.; Bjelogrlic, S.; Blair, J. T.; Blau, D.; Blume, C.; Bock, F.; Bogdanov, A.; Bøggild, H.; Boldizsár, L.; Bombara, M.; Bonora, M.; Book, J.; Borel, H.; Borissov, A.; Borri, M.; Bossú, F.; Botta, E.; Bourjau, C.; Braun-Munzinger, P.; Bregant, M.; Breitner, T.; Broker, T. A.; Browning, T. A.; Broz, M.; Brucken, E. J.; Bruna, E.; Bruno, G. E.; Budnikov, D.; Buesching, H.; Bufalino, S.; Buncic, P.; Busch, O.; Buthelezi, Z.; Butt, J. B.; Buxton, J. T.; Cabala, J.; Caffarri, D.; Cai, X.; Caines, H.; Calero Diaz, L.; Caliva, A.; Calvo Villar, E.; Camerini, P.; Carena, F.; Carena, W.; Carnesecchi, F.; Castillo Castellanos, J.; Castro, A. J.; Casula, E. A. R.; Ceballos Sanchez, C.; Cepila, J.; Cerello, P.; Cerkala, J.; Chang, B.; Chapeland, S.; Chartier, M.; Charvet, J. L.; Chattopadhyay, S.; Chattopadhyay, S.; Chauvin, A.; Chelnokov, V.; Cherney, M.; Cheshkov, C.; Cheynis, B.; Chibante Barroso, V.; Chinellato, D. D.; Cho, S.; Chochula, P.; Choi, K.; Chojnacki, M.; Choudhury, S.; Christakoglou, P.; Christensen, C. H.; Christiansen, P.; Chujo, T.; Chung, S. U.; Cicalo, C.; Cifarelli, L.; Cindolo, F.; Cleymans, J.; Colamaria, F.; Colella, D.; Collu, A.; Colocci, M.; Conesa Balbastre, G.; Conesa del Valle, Z.; Connors, M. E.; Contreras, J. G.; Cormier, T. M.; Corrales Morales, Y.; Cortés Maldonado, I.; Cortese, P.; Cosentino, M. R.; Costa, F.; Crkovska, J.; Crochet, P.; Cruz Albino, R.; Cuautle, E.; Cunqueiro, L.; Dahms, T.; Dainese, A.; Danisch, M. C.; Danu, A.; Das, D.; Das, I.; Das, S.; Dash, A.; Dash, S.; De, S.; De Caro, A.; de Cataldo, G.; de Conti, C.; de Cuveland, J.; De Falco, A.; De Gruttola, D.; De Marco, N.; De Pasquale, S.; De Souza, R. D.; Deisting, A.; Deloff, A.; Dénes, E.; Deplano, C.; Dhankher, P.; Di Bari, D.; Di Mauro, A.; Di Nezza, P.; Di Ruzza, B.; Diaz Corchero, M. A.; Dietel, T.; Dillenseger, P.; Divià, R.; Djuvsland, Ø.; Dobrin, A.; Domenicis Gimenez, D.; Dönigus, B.; Dordic, O.; Drozhzhova, T.; Dubey, A. K.; Dubla, A.; Ducroux, L.; Dupieux, P.; Ehlers, R. J.; Elia, D.; Endress, E.; Engel, H.; Epple, E.; Erazmus, B.; Erdemir, I.; Erhardt, F.; Espagnon, B.; Estienne, M.; Esumi, S.; Eulisse, G.; Eum, J.; Evans, D.; Evdokimov, S.; Eyyubova, G.; Fabbietti, L.; Fabris, D.; Faivre, J.; Fantoni, A.; Fasel, M.; Feldkamp, L.; Feliciello, A.; Feofilov, G.; Ferencei, J.; Fernández Téllez, A.; Ferreiro, E. G.; Ferretti, A.; Festanti, A.; Feuillard, V. J. G.; Figiel, J.; Figueredo, M. A. S.; Filchagin, S.; Finogeev, D.; Fionda, F. M.; Fiore, E. M.; Floris, M.; Foertsch, S.; Foka, P.; Fokin, S.; Fragiacomo, E.; Francescon, A.; Francisco, A.; Frankenfeld, U.; Fronze, G. G.; Fuchs, U.; Furget, C.; Furs, A.; Fusco Girard, M.; Gaardhøje, J. J.; Gagliardi, M.; Gago, A. M.; Gajdosova, K.; Gallio, M.; Galvan, C. D.; Gangadharan, D. R.; Ganoti, P.; Gao, C.; Garabatos, C.; Garcia-Solis, E.; Garg, K.; Gargiulo, C.; Gasik, P.; Gauger, E. F.; Germain, M.; Gheata, M.; Ghosh, P.; Ghosh, S. K.; Gianotti, P.; Giubellino, P.; Giubilato, P.; Gladysz-Dziadus, E.; Glässel, P.; Goméz Coral, D. M.; Gomez Ramirez, A.; Gonzalez, A. S.; Gonzalez, V.; González-Zamora, P.; Gorbunov, S.; Görlich, L.; Gotovac, S.; Grabski, V.; Grachov, O. A.; Graczykowski, L. K.; Graham, K. L.; Grelli, A.; Grigoras, A.; Grigoras, C.; Grigoriev, V.; Grigoryan, A.; Grigoryan, S.; Grinyov, B.; Grion, N.; Gronefeld, J. M.; Grosse-Oetringhaus, J. F.; Grosso, R.; Gruber, L.; Guber, F.; Guernane, R.; Guerzoni, B.; Gulbrandsen, K.; Gunji, T.; Gupta, A.; Gupta, R.; Guzman, I. B.; Haake, R.; Hadjidakis, C.; Haiduc, M.; Hamagaki, H.; Hamar, G.; Hamon, J. C.; Harris, J. W.; Harton, A.; Hatzifotiadou, D.; Hayashi, S.; Heckel, S. T.; Hellbär, E.; Helstrup, H.; Herghelegiu, A.; Herrera Corral, G.; Herrmann, F.; Hess, B. A.; Hetland, K. F.; Hillemanns, H.; Hippolyte, B.; Horak, D.; Hosokawa, R.; Hristov, P.; Hughes, C.; Humanic, T. J.; Hussain, N.; Hussain, T.; Hutter, D.; Hwang, D. S.; Ilkaev, R.; Inaba, M.; Incani, E.; Ippolitov, M.; Irfan, M.; Isakov, V.; Ivanov, M.; Ivanov, V.; Izucheev, V.; Jacak, B.; Jacazio, N.; Jacobs, P. M.; Jadhav, M. B.; Jadlovska, S.; Jadlovsky, J.; Jahnke, C.; Jakubowska, M. J.; Janik, M. A.; Jayarathna, P. H. S. Y.; Jena, C.; Jena, S.; Jimenez Bustamante, R. T.; Jones, P. G.; Jusko, A.; Kalinak, P.; Kalweit, A.; Kang, J. H.; Kaplin, V.; Kar, S.; Karasu Uysal, A.; Karavichev, O.; Karavicheva, T.; Karayan, L.; Karpechev, E.; Kebschull, U.; Keidel, R.; Keijdener, D. L. D.; Keil, M.; Mohisin Khan, M.; Khan, P.; Khan, S. A.; Khanzadeev, A.; Kharlov, Y.; Khatun, A.; Kileng, B.; Kim, D. W.; Kim, D. J.; Kim, D.; Kim, H.; Kim, J. S.; Kim, J.; Kim, M.; Kim, S.; Kim, T.; Kirsch, S.; Kisel, I.; Kiselev, S.; Kisiel, A.; Kiss, G.; Klay, J. L.; Klein, C.; Klein, J.; Klein-Bösing, C.; Klewin, S.; Kluge, A.; Knichel, M. L.; Knospe, A. G.; Kobdaj, C.; Kofarago, M.; Kollegger, T.; Kolojvari, A.; Kondratiev, V.; Kondratyeva, N.; Kondratyuk, E.; Konevskikh, A.; Kopcik, M.; Kour, M.; Kouzinopoulos, C.; Kovalenko, O.; Kovalenko, V.; Kowalski, M.; Koyithatta Meethaleveedu, G.; Králik, I.; Kravčáková, A.; Krivda, M.; Krizek, F.; Kryshen, E.; Krzewicki, M.; Kubera, A. M.; Kučera, V.; Kuhn, C.; Kuijer, P. G.; Kumar, A.; Kumar, J.; Kumar, L.; Kumar, S.; Kurashvili, P.; Kurepin, A.; Kurepin, A. B.; Kuryakin, A.; Kweon, M. J.; Kwon, Y.; La Pointe, S. L.; La Rocca, P.; Ladron de Guevara, P.; Lagana Fernandes, C.; Lakomov, I.; Langoy, R.; Lapidus, K.; Lara, C.; Lardeux, A.; Lattuca, A.; Laudi, E.; Lea, R.; Leardini, L.; Lee, S.; Lehas, F.; Lehner, S.; Lemmon, R. C.; Lenti, V.; Leogrande, E.; León Monzón, I.; León Vargas, H.; Leoncino, M.; Lévai, P.; Li, S.; Li, X.; Lien, J.; Lietava, R.; Lindal, S.; Lindenstruth, V.; Lippmann, C.; Lisa, M. A.; Ljunggren, H. M.; Lodato, D. F.; Loenne, P. I.; Loginov, V.; Loizides, C.; Lopez, X.; López Torres, E.; Lowe, A.; Luettig, P.; Lunardon, M.; Luparello, G.; Lupi, M.; Lutz, T. H.; Maevskaya, A.; Mager, M.; Mahajan, S.; Mahmood, S. M.; Maire, A.; Majka, R. D.; Malaev, M.; Maldonado Cervantes, I.; Malinina, L.; Mal'Kevich, D.; Malzacher, P.; Mamonov, A.; Manko, V.; Manso, F.; Manzari, V.; Mao, Y.; Marchisone, M.; Mareš, J.; Margagliotti, G. V.; Margotti, A.; Margutti, J.; Marín, A.; Markert, C.; Marquard, M.; Martin, N. A.; Martinengo, P.; Martínez, M. I.; Martínez García, G.; Martinez Pedreira, M.; Mas, A.; Masciocchi, S.; Masera, M.; Masoni, A.; Mastroserio, A.; Matyja, A.; Mayer, C.; Mazer, J.; Mazzilli, M.; Mazzoni, M. A.; Meddi, F.; Melikyan, Y.; Menchaca-Rocha, A.; Meninno, E.; Mercado Pérez, J.; Meres, M.; Mhlanga, S.; Miake, Y.; Mieskolainen, M. M.; Mikhaylov, K.; Milano, L.; Milosevic, J.; Mischke, A.; Mishra, A. N.; Mishra, T.; Miskowiec, D.; Mitra, J.; Mitu, C. M.; Mohammadi, N.; Mohanty, B.; Molnar, L.; Montaño Zetina, L.; Montes, E.; Moreira De Godoy, D. A.; Moreno, L. A. P.; Moretto, S.; Morreale, A.; Morsch, A.; Muccifora, V.; Mudnic, E.; Mühlheim, D.; Muhuri, S.; Mukherjee, M.; Mulligan, J. D.; Munhoz, M. G.; Münning, K.; Munzer, R. H.; Murakami, H.; Murray, S.; Musa, L.; Musinsky, J.; Naik, B.; Nair, R.; Nandi, B. K.; Nania, R.; Nappi, E.; Naru, M. U.; Natal da Luz, H.; Nattrass, C.; Navarro, S. R.; Nayak, K.; Nayak, R.; Nayak, T. K.; Nazarenko, S.; Nedosekin, A.; Negrao De Oliveira, R. A.; Nellen, L.; Ng, F.; Nicassio, M.; Niculescu, M.; Niedziela, J.; Nielsen, B. S.; Nikolaev, S.; Nikulin, S.; Nikulin, V.; Noferini, F.; Nomokonov, P.; Nooren, G.; Noris, J. C. C.; Norman, J.; Nyanin, A.; Nystrand, J.; Oeschler, H.; Oh, S.; Oh, S. K.; Ohlson, A.; Okatan, A.; Okubo, T.; Oleniacz, J.; Oliveira Da Silva, A. C.; Oliver, M. H.; Onderwaater, J.; Oppedisano, C.; Orava, R.; Oravec, M.; Ortiz Velasquez, A.; Oskarsson, A.; Otwinowski, J.; Oyama, K.; Ozdemir, M.; Pachmayer, Y.; Pagano, D.; Pagano, P.; Paić, G.; Pal, S. K.; Palni, P.; Pan, J.; Pandey, A. K.; Papikyan, V.; Pappalardo, G. S.; Pareek, P.; Park, W. J.; Parmar, S.; Passfeld, A.; Paticchio, V.; Patra, R. N.; Paul, B.; Pei, H.; Peitzmann, T.; Peng, X.; Pereira Da Costa, H.; Peresunko, D.; Perez Lezama, E.; Peskov, V.; Pestov, Y.; Petráček, V.; Petrov, V.; Petrovici, M.; Petta, C.; Piano, S.; Pikna, M.; Pillot, P.; Pimentel, L. O. D. L.; Pinazza, O.; Pinsky, L.; Piyarathna, D. B.; Ploskon, M.; Planinic, M.; Pluta, J.; Pochybova, S.; Podesta-Lerma, P. L. M.; Poghosyan, M. G.; Polichtchouk, B.; Poljak, N.; Poonsawat, W.; Pop, A.; Poppenborg, H.; Porteboeuf-Houssais, S.; Porter, J.; Pospisil, J.; Prasad, S. K.; Preghenella, R.; Prino, F.; Pruneau, C. A.; Pshenichnov, I.; Puccio, M.; Puddu, G.; Pujahari, P.; Punin, V.; Putschke, J.; Qvigstad, H.; Rachevski, A.; Raha, S.; Rajput, S.; Rak, J.; Rakotozafindrabe, A.; Ramello, L.; Rami, F.; Raniwala, R.; Raniwala, S.; Räsänen, S. S.; Rascanu, B. T.; Rathee, D.; Ravasenga, I.; Read, K. F.; Redlich, K.; Reed, R. J.; Rehman, A.; Reichelt, P.; Reidt, F.; Ren, X.; Renfordt, R.; Reolon, A. R.; Reshetin, A.; Reygers, K.; Riabov, V.; Ricci, R. A.; Richert, T.; Richter, M.; Riedler, P.; Riegler, W.; Riggi, F.; Ristea, C.; Rodríguez Cahuantzi, M.; Rodriguez Manso, A.; Røed, K.; Rogochaya, E.; Rohr, D.; Röhrich, D.; Ronchetti, F.; Ronflette, L.; Rosnet, P.; Rossi, A.; Roukoutakis, F.; Roy, A.; Roy, C.; Roy, P.; Rubio Montero, A. J.; Rui, R.; Russo, R.; Ryabinkin, E.; Ryabov, Y.; Rybicki, A.; Saarinen, S.; Sadhu, S.; Sadovsky, S.; Šafařík, K.; Sahlmuller, B.; Sahoo, P.; Sahoo, R.; Sahoo, S.; Sahu, P. K.; Saini, J.; Sakai, S.; Saleh, M. A.; Salzwedel, J.; Sambyal, S.; Samsonov, V.; Šándor, L.; Sandoval, A.; Sano, M.; Sarkar, D.; Sarkar, N.; Sarma, P.; Scapparone, E.; Scarlassara, F.; Schiaua, C.; Schicker, R.; Schmidt, C.; Schmidt, H. R.; Schmidt, M.; Schuchmann, S.; Schukraft, J.; Schutz, Y.; Schwarz, K.; Schweda, K.; Scioli, G.; Scomparin, E.; Scott, R.; Šefčík, M.; Seger, J. E.; Sekiguchi, Y.; Sekihata, D.; Selyuzhenkov, I.; Senosi, K.; Senyukov, S.; Serradilla, E.; Sevcenco, A.; Shabanov, A.; Shabetai, A.; Shadura, O.; Shahoyan, R.; Shangaraev, A.; Sharma, A.; Sharma, M.; Sharma, M.; Sharma, N.; Sheikh, A. I.; Shigaki, K.; Shou, Q.; Shtejer, K.; Sibiriak, Y.; Siddhanta, S.; Sielewicz, K. M.; Siemiarczuk, T.; Silvermyr, D.; Silvestre, C.; Simatovic, G.; Simonetti, G.; Singaraju, R.; Singh, R.; Singhal, V.; Sinha, T.; Sitar, B.; Sitta, M.; Skaali, T. B.; Slupecki, M.; Smirnov, N.; Snellings, R. J. M.; Snellman, T. W.; Song, J.; Song, M.; Song, Z.; Soramel, F.; Sorensen, S.; Sozzi, F.; Spiriti, E.; Sputowska, I.; Spyropoulou-Stassinaki, M.; Stachel, J.; Stan, I.; Stankus, P.; Stenlund, E.; Steyn, G.; Stiller, J. H.; Stocco, D.; Strmen, P.; Suaide, A. A. P.; Sugitate, T.; Suire, C.; Suleymanov, M.; Suljic, M.; Sultanov, R.; Šumbera, M.; Sumowidagdo, S.; Swain, S.; Szabo, A.; Szarka, I.; Szczepankiewicz, A.; Szymanski, M.; Tabassam, U.; Takahashi, J.; Tambave, G. J.; Tanaka, N.; Tarhini, M.; Tariq, M.; Tarzila, M. G.; Tauro, A.; Tejeda Muñoz, G.; Telesca, A.; Terasaki, K.; Terrevoli, C.; Teyssier, B.; Thäder, J.; Thakur, D.; Thomas, D.; Tieulent, R.; Tikhonov, A.; Timmins, A. R.; Toia, A.; Trogolo, S.; Trombetta, G.; Trubnikov, V.; Trzaska, W. H.; Tsuji, T.; Tumkin, A.; Turrisi, R.; Tveter, T. S.; Ullaland, K.; Uras, A.; Usai, G. L.; Utrobicic, A.; Vala, M.; Valencia Palomo, L.; Van Der Maarel, J.; Van Hoorne, J. W.; van Leeuwen, M.; Vanat, T.; Vande Vyvre, P.; Varga, D.; Vargas, A.; Vargyas, M.; Varma, R.; Vasileiou, M.; Vasiliev, A.; Vauthier, A.; Vázquez Doce, O.; Vechernin, V.; Veen, A. M.; Velure, A.; Vercellin, E.; Vergara Limón, S.; Vernet, R.; Vickovic, L.; Viinikainen, J.; Vilakazi, Z.; Villalobos Baillie, O.; Villatoro Tello, A.; Vinogradov, A.; Vinogradov, L.; Virgili, T.; Vislavicius, V.; Viyogi, Y. P.; Vodopyanov, A.; Völkl, M. A.; Voloshin, K.; Voloshin, S. A.; Volpe, G.; von Haller, B.; Vorobyev, I.; Vranic, D.; Vrláková, J.; Vulpescu, B.; Wagner, B.; Wagner, J.; Wang, H.; Wang, M.; Watanabe, D.; Watanabe, Y.; Weber, M.; Weber, S. G.; Weiser, D. F.; Wessels, J. P.; Westerhoff, U.; Whitehead, A. M.; Wiechula, J.; Wikne, J.; Wilk, G.; Wilkinson, J.; Willems, G. A.; Williams, M. C. S.; Windelband, B.; Winn, M.; Yalcin, S.; Yang, P.; Yano, S.; Yin, Z.; Yokoyama, H.; Yoo, I.-K.; Yoon, J. H.; Yurchenko, V.; Zaborowska, A.; Zaccolo, V.; Zaman, A.; Zampolli, C.; Zanoli, H. J. C.; Zaporozhets, S.; Zardoshti, N.; Zarochentsev, A.; Závada, P.; Zaviyalov, N.; Zbroszczyk, H.; Zgura, I. S.; Zhalov, M.; Zhang, H.; Zhang, X.; Zhang, Y.; Zhang, C.; Zhang, Z.; Zhao, C.; Zhigareva, N.; Zhou, D.; Zhou, Y.; Zhou, Z.; Zhu, H.; Zhu, J.; Zichichi, A.; Zimmermann, A.; Zimmermann, M. B.; Zinovjev, G.; Zyzak, M.
2016-09-01
The elliptic, triangular, quadrangular and pentagonal anisotropic flow coefficients for π±, K± and p+overline{p} in Pb-Pb collisions at √{s_{NN}}=2.76 TeV were measured with the ALICE detector at the Large Hadron Collider. The results were obtained with the Scalar Product method, correlating the identified hadrons with reference particles from a different pseudorapidity region. Effects not related to the common event symmetry planes (non-flow) were estimated using correlations in pp collisions and were subtracted from the measurement. The obtained flow coefficients exhibit a clear mass ordering for transverse momentum ( p T) values below ≈ 3 GeV/ c. In the intermediate p T region (3 < p T < 6 GeV/ c), particles group at an approximate level according to the number of constituent quarks, suggesting that coalescence might be the relevant particle production mechanism in this region. The results for p T < 3 GeV/ c are described fairly well by a hydrodynamical model (iEBE-VISHNU) that uses initial conditions generated by A Multi-Phase Transport model (AMPT) and describes the expansion of the fireball using a value of 0.08 for the ratio of shear viscosity to entropy density ( η/s), coupled to a hadronic cascade model (UrQMD). Finally, expectations from AMPT alone fail to quantitatively describe the measurements for all harmonics throughout the measured transverse momentum region. However, the comparison to the AMPT model highlights the importance of the late hadronic rescattering stage to the development of the observed mass ordering at low values of p T and of coalescence as a particle production mechanism for the particle type grouping at intermediate values of p T for all harmonics. [Figure not available: see fulltext.
Adam, J.; Adamová, D.; Aggarwal, M. M.; ...
2016-09-28
The elliptic, triangular, quadrangular and pentagonal anisotropic flow coefficients for π ± , K ± and p +more » $$\\bar{p}$$ in Pb-Pb collisions at √s NN=2.76 TeV were measured with the ALICE detector at the Large Hadron Collider. The results were obtained with the Scalar Product method, correlating the identified hadrons with reference particles from a different pseudorapidity region. Effects not related to the common event symmetry planes (non-flow) were estimated using correlations in pp collisions and were subtracted from the measurement. The obtained flow coefficients exhibit a clear mass ordering for transverse momentum (p T ) values below ≈ 3 GeV/c. In the intermediate p T region (3 < p T < 6 GeV/c), particles group at an approximate level according to the number of constituent quarks, suggesting that coalescence might be the relevant particle production mechanism in this region. The results for p T < 3 GeV/c are described fairly well by a hydrodynamical model (iEBE-VISHNU) that uses initial conditions generated by A Multi-Phase Transport model (AMPT) and describes the expansion of the fireball using a value of 0.08 for the ratio of shear viscosity to entropy density (η/s), coupled to a hadronic cascade model (UrQMD). Finally, expectations from AMPT alone fail to quantitatively describe the measurements for all harmonics throughout the measured transverse momentum region. However, the comparison to the AMPT model highlights the importance of the late hadronic rescattering stage to the development of the observed mass ordering at low values of p T and of coalescence as a particle production mechanism for the particle type grouping at intermediate values of p T for all harmonics.« less
Predicting a contact's sensitivity to initial conditions using metrics of frictional coupling
Flicek, Robert C.; Hills, David A.; Brake, Matthew Robert W.
2016-09-29
This paper presents a method for predicting how sensitive a frictional contact’s steady-state behavior is to its initial conditions. Previous research has proven that if a contact is uncoupled, i.e. if slip displacements do not influence the contact pressure distribution, then its steady-state response is independent of initial conditions, but if the contact is coupled, the steady-state response depends on initial conditions. In this paper, two metrics for quantifying coupling in discrete frictional systems are examined. These metrics suggest that coupling is dominated by material dissimilarity due to Dundurs’ composite material parameter β when β ≥ 0.2, but geometric mismatchmore » becomes the dominant source of coupling for smaller values of β. Based on a large set of numerical simulations with different contact geometries, material combinations, and friction coefficients, a contact’s sensitivity to initial conditions is found to be correlated with the product of the coupling metric and the friction coefficient. For cyclic shear loading, this correlation is maintained for simulations with different contact geometries, material combinations, and friction coefficients. Furthermore, for cyclic bulk loading, the correlation is only maintained when the contact edge angle is held constant.« less
Predicting a contact's sensitivity to initial conditions using metrics of frictional coupling
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flicek, Robert C.; Hills, David A.; Brake, Matthew Robert W.
This paper presents a method for predicting how sensitive a frictional contact’s steady-state behavior is to its initial conditions. Previous research has proven that if a contact is uncoupled, i.e. if slip displacements do not influence the contact pressure distribution, then its steady-state response is independent of initial conditions, but if the contact is coupled, the steady-state response depends on initial conditions. In this paper, two metrics for quantifying coupling in discrete frictional systems are examined. These metrics suggest that coupling is dominated by material dissimilarity due to Dundurs’ composite material parameter β when β ≥ 0.2, but geometric mismatchmore » becomes the dominant source of coupling for smaller values of β. Based on a large set of numerical simulations with different contact geometries, material combinations, and friction coefficients, a contact’s sensitivity to initial conditions is found to be correlated with the product of the coupling metric and the friction coefficient. For cyclic shear loading, this correlation is maintained for simulations with different contact geometries, material combinations, and friction coefficients. Furthermore, for cyclic bulk loading, the correlation is only maintained when the contact edge angle is held constant.« less
Peyrard, N; Dieckmann, U; Franc, A
2008-05-01
Models of infectious diseases are characterized by a phase transition between extinction and persistence. A challenge in contemporary epidemiology is to understand how the geometry of a host's interaction network influences disease dynamics close to the critical point of such a transition. Here we address this challenge with the help of moment closures. Traditional moment closures, however, do not provide satisfactory predictions close to such critical points. We therefore introduce a new method for incorporating longer-range correlations into existing closures. Our method is technically simple, remains computationally tractable and significantly improves the approximation's performance. Our extended closures thus provide an innovative tool for quantifying the influence of interaction networks on spatially or socially structured disease dynamics. In particular, we examine the effects of a network's clustering coefficient, as well as of new geometrical measures, such as a network's square clustering coefficients. We compare the relative performance of different closures from the literature, with or without our long-range extension. In this way, we demonstrate that the normalized version of the Bethe approximation-extended to incorporate long-range correlations according to our method-is an especially good candidate for studying influences of network structure. Our numerical results highlight the importance of the clustering coefficient and the square clustering coefficient for predicting disease dynamics at low and intermediate values of transmission rate, and demonstrate the significance of path redundancy for disease persistence.
2009-07-16
0.25 0.26 -0.85 1 SSR SSE R SSTO SSTO = = − 2 2 ˆ( ) : Regression sum of square, ˆwhere : mean value, : value from the fitted line ˆ...Error sum of square : Total sum of square i i i i SSR Y Y Y Y SSE Y Y SSTO SSE SSR = − = − = + ∑ ∑ Statistical analysis: Coefficient of correlation
Liver reserve function assessment by acoustic radiation force impulse imaging
Sun, Xiao-Lan; Liang, Li-Wei; Cao, Hui; Men, Qiong; Hou, Ke-Zhu; Chen, Zhen; Zhao, Ya-E
2015-01-01
AIM: To evaluate the utility of liver reserve function by acoustic radiation force impulse (ARFI) imaging in patients with liver tumors. METHODS: Seventy-six patients with liver tumors were enrolled in this study. Serum biochemical indexes, such as aminotransferase (ALT), aspartate aminotransferase (AST), serum albumin (ALB), total bilirubin (T-Bil), and other indicators were observed. Liver stiffness (LS) was measured by ARFI imaging, measurements were repeated 10 times, and the average value of the results was taken as the final LS value. Indocyanine green (ICG) retention was performed, and ICG-K and ICG-R15 were recorded. Child-Pugh (CP) scores were carried out based on patient’s preoperative biochemical tests and physical condition. Correlations among CP scores, ICG-R15, ICG-K and LS values were observed and analyzed using either the Pearson correlation coefficient or the Spearman rank correlation coefficient. Kruskal-Wallis test was used to compare LS values of CP scores, and the receiver-operator characteristic (ROC) curve was used to analyze liver reserve function assessment accuracy. RESULTS: LS in the ICG-R15 10%-20% group was significantly higher than in the ICG-R15 < 10% group; and the difference was statistically significant (2.19 ± 0.27 vs 1.59 ± 0.32, P < 0.01). LS in the ICG-R15 > 20% group was significantly higher than in the ICG-R15 < 10% group; and the difference was statistically significant (2.92 ± 0.29 vs 1.59 ± 0.32, P < 0.01). The LS value in patients with CP class A was lower than in patients with CP class B (1.57 ± 0.34 vs 1.86 ± 0.27, P < 0.05), while the LS value in patients with CP class B was lower than in patients with CP class C (1.86 ± 0.27 vs 2.47 ± 0.33, P < 0.01). LS was positively correlated with ICG-R15 (r = 0.617, P < 0.01) and CP score (r = 0.772, P < 0.01). Meanwhile, LS was negatively correlated with ICG-K (r = -0.673, P < 0.01). AST, ALT and T-Bil were positively correlated with LS, while ALB was negatively correlated with LS (P < 0.05). The ROC curve revealed that the when the LS value was 2.34 m/s, the Youden index was at its highest point, sensitivity was 69.2% and specificity was 92.1%. CONCLUSION: For patients with liver tumors, ARFI imaging is a useful tool for assessing liver reserve function. PMID:26327773
Estimation of the biserial correlation and its sampling variance for use in meta-analysis.
Jacobs, Perke; Viechtbauer, Wolfgang
2017-06-01
Meta-analyses are often used to synthesize the findings of studies examining the correlational relationship between two continuous variables. When only dichotomous measurements are available for one of the two variables, the biserial correlation coefficient can be used to estimate the product-moment correlation between the two underlying continuous variables. Unlike the point-biserial correlation coefficient, biserial correlation coefficients can therefore be integrated with product-moment correlation coefficients in the same meta-analysis. The present article describes the estimation of the biserial correlation coefficient for meta-analytic purposes and reports simulation results comparing different methods for estimating the coefficient's sampling variance. The findings indicate that commonly employed methods yield inconsistent estimates of the sampling variance across a broad range of research situations. In contrast, consistent estimates can be obtained using two methods that appear to be unknown in the meta-analytic literature. A variance-stabilizing transformation for the biserial correlation coefficient is described that allows for the construction of confidence intervals for individual coefficients with close to nominal coverage probabilities in most of the examined conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Michel, Yvonne Anne; Augestad, Liv Ariane; Rand, Kim
2018-04-01
The 15D is a generic preference-based health-related quality-of-life instrument developed in Finland. Values for the 15D instrument are estimated by combining responses to three distinct valuation tasks. The impact of how these tasks are combined is relatively unexplored. To compare 15D valuation studies conducted in Norway and Finland in terms of scores assigned in the valuation tasks and resulting value algorithms, and to discuss the contributions of each task and the algorithm estimation procedure to observed differences. Norwegian and Finnish scores from the three valuation tasks were compared using independent samples t tests and Lin concordance correlation coefficients. Covariance between tasks was assessed using Pearson product-moment correlations. Norwegian and Finnish value algorithms were compared using concordance correlation coefficients, total ranges, and ranges for individual dimensions. Observed differences were assessed using minimal important difference. Mean scores in the main valuation task were strikingly similar between the two countries, whereas the final value algorithms were less similar. The largest differences between Norway and Finland were observed for depression, vision, and mental function. 15D algorithms are a product of combining scores from three valuation tasks by use of methods involving multiplication. This procedure used to combine scores from the three tasks by multiplication serves to amplify variance from each task. From relatively similar responses in Norway and Finland, diverging value algorithms are created. We propose to simplify the 15D algorithm estimation procedure by using only one of the valuation tasks. Copyright © 2018 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.
Segal, Neil A; Frick, Eric; Duryea, Jeffrey; Nevitt, Michael C; Niu, Jingbo; Torner, James C; Felson, David T; Anderson, Donald D
2017-07-01
The objective of this project was to determine the relationship between medial tibiofemoral joint space width measured on fixed-flexion radiographs and the three-dimensional joint space width distribution on low-dose, standing CT (SCT) imaging. At the 84-month visit of the Multicenter Osteoarthritis Study, 20 participants were recruited. A commercial SCT scanner for the foot and ankle was modified to image knees while standing. Medial tibiofemoral joint space width was assessed on radiographs at fixed locations from 15% to 30% of compartment width using validated software and on SCT by mapping the distances between three-dimensional subchondral bone surfaces. Individual joint space width values from radiographs were compared with three-dimensional joint space width values from corresponding sagittal plane locations using paired t-tests and correlation coefficients. For the four medial-most tibiofemoral locations, radiographic joint space width values exceeded the minimal joint space width on SCT by a mean of 2.0 mm and were approximately equal to the 61st percentile value of the joint space width distribution at each respective sagittal-plane location. Correlation coefficients at these locations were 0.91-0.97 and the offsets between joint space width values from radiographs and SCT measurements were consistent. There were greater offsets and variability in the offsets between modalities closer to the tibial spine. Joint space width measurements on fixed-flexion radiographs are highly correlated with three-dimensional joint space width from SCT. In addition to avoiding bony overlap obscuring the joint, a limitation of radiographs, the current study supports a role for SCT in the evaluation of tibiofemoral OA. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1388-1395, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Bouti, Khalid; Benamor, Jouda; Bourkadi, Jamal Eddine
2017-08-01
Peak Expiratory Flow (PEF) has never been characterised among healthy Moroccan school children. To study the relationship between PEF and anthropometric parameters (sex, age, height and weight) in healthy Moroccan school children, to establish predictive equations of PEF; and to compare flowmetric and spirometric PEF with Forced Expiratory Volume in 1 second (FEV1). This cross-sectional study was conducted between April, 2016 and May, 2016. It involved 222 (122 boys and 100 girls) healthy school children living in Ksar el-Kebir, Morocco. We used mobile equipments for realisation of spirometry and peak expiratory flow measurements. SPSS (Version 22.0) was used to calculate Student's t-test, Pearson's correlation coefficient and linear regression. Significant linear correlation was seen between PEF, age and height in boys and girls. The equation for prediction of flowmetric PEF in boys was calculated as 'F-PEF = -187+ 24.4 Age + 1.61 Height' (p-value<0.001, r=0.86), and for girls as 'F-PEF = -151 + 17Age + 1.59Height' (p-value<0.001, r=0.86). The equation for prediction of spirometric PEF in boys was calculated as 'S-PEF = -199+ 9.8Age + 2.67Height' (p-value<0.05, r=0.77), and for girls as 'S-PEF = -181 + 8.5Age + 2.5Height' (p-value<0.001, r=0.83). The boys had higher values than the girls. The performance of the Mini Wright Peak Flow Meter was lower than that of a spirometer. Our study established PEF predictive equations in Moroccan children. Our results appeared to be reliable, as evident by the high correlation coefficient in this sample. PEF can be an alternative of FEV1 in centers without spirometry.
Variability of dental cone beam CT grey values for density estimations
Pauwels, R; Nackaerts, O; Bellaiche, N; Stamatakis, H; Tsiklakis, K; Walker, A; Bosmans, H; Bogaerts, R; Jacobs, R; Horner, K
2013-01-01
Objective The aim of this study was to investigate the use of dental cone beam CT (CBCT) grey values for density estimations by calculating the correlation with multislice CT (MSCT) values and the grey value error after recalibration. Methods A polymethyl methacrylate (PMMA) phantom was developed containing inserts of different density: air, PMMA, hydroxyapatite (HA) 50 mg cm−3, HA 100, HA 200 and aluminium. The phantom was scanned on 13 CBCT devices and 1 MSCT device. Correlation between CBCT grey values and CT numbers was calculated, and the average error of the CBCT values was estimated in the medium-density range after recalibration. Results Pearson correlation coefficients ranged between 0.7014 and 0.9996 in the full-density range and between 0.5620 and 0.9991 in the medium-density range. The average error of CBCT voxel values in the medium-density range was between 35 and 1562. Conclusion Even though most CBCT devices showed a good overall correlation with CT numbers, large errors can be seen when using the grey values in a quantitative way. Although it could be possible to obtain pseudo-Hounsfield units from certain CBCTs, alternative methods of assessing bone tissue should be further investigated. Advances in knowledge The suitability of dental CBCT for density estimations was assessed, involving a large number of devices and protocols. The possibility for grey value calibration was thoroughly investigated. PMID:23255537
Altuntas, Nilgun; Turkyilmaz, Canan; Yildiz, Havva; Kulali, Ferit; Hirfanoglu, Ibrahim; Onal, Esra; Ergenekon, Ebru; Koç, Esin; Atalay, Yıldız
2014-05-01
We aimed to evaluate the validity and reliability of the Infant Breastfeeding Assessment Tool (IBFAT), the Mother Baby Assessment (MBA) Tool, and the LATCH scoring system. Mothers who delivered healthy, full-term infants in the Obstetrics & Gynecology Service of Gazi University, Ankara, Turkey, between December 2013 and January 2014 and their infants were included in the study. Forty-six randomly selected breastfeeding sessions were monitored and scored simultaneously by three researchers (Raters 1, 2, and 3) using LATCH, IBFAT, and the MBA Tool. Researchers put the score sheets in an envelope in order to hide them from each other. The compatibility of the scores given by three researchers was assessed by statistical methods. We found positive and significant correlation coefficients between 0.81 to 0.88 for the total MBA score, between 0.90 to 0.95 for the total IBFAT score, and between 0.85 to 0.91 for the total LATCH score. Correlation coefficients testing these three tools ranged from 0.71 to 0.88, with the minimum value being noted for the correlation between LATCH and IBFAT scores and the maximum value being noted for the correlation between LATCH and MBA scores. We found positive and significant correlations between researchers' scores for 46 observations using the three assessment tools. This study showed that these above-mentioned tools were compatible for the assessment of the efficiency of breastfeeding.
Tree-Ring Widths and Snow Cover Depth in High Tauern
NASA Astrophysics Data System (ADS)
Falarz, Malgorzata
2017-12-01
The aim of the study is to examine the correlation of Norway spruce tree-ring widths and the snow cover depth in the High Tauern mountains. The average standardized tree-ring widths indices for Nowary spruce posted by Bednarz and Niedzwiedz (2006) were taken into account. Increment cores were collected from 39 Norway spruces growing in the High Tauern near the upper limit of the forest at altitude of 1700-1800 m, 3 km from the meteorological station at Sonnblick. Moreover, the maximum of snow cover depth in Sonnblick (3105 m a.s.l.) for each winter season in the period from 1938/39 to 1994/95 (57 winter seasons) was taken into account. The main results of the research are as follows: (1) tree-ring widths in a given year does not reveal statistically significant dependency on the maximum snow cover depth observed in the winter season, which ended this year; (2) however, the tested relationship is statistically significant in the case of correlating of the tree-ring widths in a given year with a maximum snow cover depth in a season of previous year. The correlation coefficient for the entire period of the study is not very high (r=0.27) but shows a statistical significance at the 0.05 level; (3) the described relationship is not stable over time. 30-year moving correlations showed no significant dependencies till 1942 and after 1982 (probably due to the so-called divergence phenomenon). However, during the period of 1943-1981 the values of correlation coefficient for moving 30-year periods are statistically significant and range from 0.37 to 0.45; (4) the correlation coefficient between real and calibrated (on the base of the regression equation) values of maximum snow cover depth is statistically significant for calibration period and not significant for verification one; (5) due to a quite short period of statistically significant correlations and not very strict dependencies, the reconstruction of snow cover on Sonnblick for the period before regular measurements seems to be not reasonable.
Selectivity of similar compounds' identification using IR spectrometry: β-Lactam antibiotics
NASA Astrophysics Data System (ADS)
Sadlej-Sosnowska, Nina; Ocios, Agnieszka; Fuks, Leon
2006-07-01
The study aims to develop a reliable, quantitative method for positive identification or discrimination of a substance, when it is compared to a set of similar ones. In the course of the study a group of structurally related compounds, namely a set of β-lactam antimicrobial agents has been explored. Identification of a substance was based on the comparison of its spectrum with that of a reference material by using two functional algorithms. The algorithm based on the calculation of correlation coefficient between the first derivatives of the spectra has been proved more powerful than that using the original spectra. Then the results in a few spectral regions were likened. Limiting values were proposed for correlation coefficients that allow for qualification of a substance as identical to the reference one.
Empirical analysis on future-cash arbitrage risk with portfolio VaR
NASA Astrophysics Data System (ADS)
Chen, Rongda; Li, Cong; Wang, Weijin; Wang, Ze
2014-03-01
This paper constructs the positive arbitrage position by alternating the spot index with Chinese Exchange Traded Fund (ETF) portfolio and estimating the arbitrage-free interval of futures with the latest trade data. Then, an improved Delta-normal method was used, which replaces the simple linear correlation coefficient with tail dependence correlation coefficient, to measure VaR (Value-at-risk) of the arbitrage position. Analysis of VaR implies that the risk of future-cash arbitrage is less than that of investing completely in either futures or spot market. Then according to the compositional VaR and the marginal VaR, we should increase the futures position and decrease the spot position appropriately to minimize the VaR, which can minimize risk subject to certain revenues.
SU-E-J-242: Volume-Dependence of Quantitative Imaging Features From CT and CE-CT Images of NSCLC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fave, X; Fried, D; UT Health Science Center Graduate School of Biomedical Sciences, Houston, TX
Purpose: To determine whether tumor volume plays a significant role in the values obtained for texture features when they are extracted from computed tomography (CT) images of non-small cell lung cancer (NSCLC). We also sought to identify whether features can be reliably measured at all volumes or if a minimum volume threshold should be recommended. Methods: Eleven features were measured on 40 CT and 32 contrast-enhanced CT (CECT) patient images for this study. Features were selected for their prognostic/diagnostic value in previous publications. Direct correlations between these textures and volume were evaluated using the Spearman correlation coefficient. Any texture thatmore » the Wilcoxon rank-sum test was used to compare the variation above and below a volume cutoff. Four different volume thresholds (5, 10, 15, and 20 cm{sup 3}) were tested. Results: Four textures were found to be significantly correlated with volume in both the CT and CE-CT images. These were busyness, coarseness, gray-level nonuniformity, and run-length nonuniformity with correlation coefficients of 0.92, −0.96, 0.94, and 0.98 for the CT images and 0.95, −0.97, 0.98, and 0.98 for the CE-CT images. After volume normalization, the correlation coefficients decreased substantially. For the data obtained from the CT images, the results of the Wilcoxon rank-sum test were significant when volume thresholds of 5–15 cm3 were used. No volume threshold was shown to be significant for the CE-CT data. Conclusion: Equations for four features that have been used in several published studies were found to be volume-dependent. Future studies should consider implementing normalization factors or removing these features entirely to prevent this potential source of redundancy or bias. This work was supported in part by National Cancer Institute grant R03CA178495-01. Xenia Fave is a recipient of the American Association of Physicists in Medicine Graduate Fellowship.« less
Ye, Zhi-Min; Dai, Shu-Jun; Yan, Feng-Qin; Wang, Lei; Fang, Jun; Fu, Zhen-Fu; Wang, Yue-Zhen
2018-01-01
This study aimed to evaluate both the short- and long-term efficacies of chemoradiotherapy in relation to the treatment of esophageal cancer . This was achieved through the use of dynamic contrast-enhanced magnetic resonance imaging-derived volume transfer constant and diffusion weighted imaging-derived apparent diffusion coefficient . Patients with esophageal cancer were assigned into the sensitive and resistant groups based on respective efficacies in chemoradiotherapy. Dynamic contrast-enhanced magnetic resonance imaging and diffusion weighted imaging were used to measure volume transfer constant and apparent diffusion coefficient, while computed tomography was used to calculate tumor size reduction rate. Pearson correlation analyses were conducted to analyze correlation between volume transfer constant, apparent diffusion coefficient, and the tumor size reduction rate. Receiver operating characteristic curve was constructed to analyze the short-term efficacy of volume transfer constant and apparent diffusion coefficient, while Kaplan-Meier curve was employed for survival rate analysis. Cox proportional hazard model was used for the risk factors for prognosis of patients with esophageal cancer. Our results indicated reduced levels of volume transfer constant, while increased levels were observed in ADC min , ADC mean , and ADC max following chemoradiotherapy. A negative correlation was determined between ADC min , ADC mean , and ADC max , as well as in the tumor size reduction rate prior to chemoradiotherapy, whereas a positive correlation was uncovered postchemoradiotherapy. Volume transfer constant was positively correlated with tumor size reduction rate both before and after chemoradiotherapy. The 5-year survival rate of patients with esophageal cancer having high ADC min , ADC mean , and ADC max and volume transfer constant before chemoradiotherapy was greater than those with respectively lower values. According to the Cox proportional hazard model, ADC mean , clinical stage, degree of differentiation, and tumor stage were all confirmed as being independent risk factors in regard to the prognosis of patients with EC. The findings of this study provide evidence suggesting that volume transfer constant and apparent diffusion coefficient as being tools allowing for the evaluation of both the short- and long-term efficacies of chemoradiotherapy esophageal cancer treatment.
Estimation of the simple correlation coefficient.
Shieh, Gwowen
2010-11-01
This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.
Zhang, Yujuan; Chen, Jun; Liu, Song; Shi, Hua; Guan, Wenxian; Ji, Changfeng; Guo, Tingting; Zheng, Huanhuan; Guan, Yue; Ge, Yun; He, Jian; Zhou, Zhengyang; Yang, Xiaofeng; Liu, Tian
2017-02-01
To investigate the efficacy of histogram analysis of the entire tumor volume in apparent diffusion coefficient (ADC) maps for differentiating between histological grades in gastric cancer. Seventy-eight patients with gastric cancer were enrolled in a retrospective 3.0T magnetic resonance imaging (MRI) study. ADC maps were obtained at two different b values (0 and 1000 sec/mm 2 ) for each patient. Tumors were delineated on each slice of the ADC maps, and a histogram for the entire tumor volume was subsequently generated. A series of histogram parameters (eg, skew and kurtosis) were calculated and correlated with the histological grade of the surgical specimen. The diagnostic performance of each parameter for distinguishing poorly from moderately well-differentiated gastric cancers was assessed by using the area under the receiver operating characteristic curve (AUC). There were significant differences in the 5 th , 10 th , 25 th , and 50 th percentiles, skew, and kurtosis between poorly and well-differentiated gastric cancers (P < 0.05). There were correlations between the degrees of differentiation and histogram parameters, including the 10 th percentile, skew, kurtosis, and max frequency; the correlation coefficients were 0.273, -0.361, -0.339, and -0.370, respectively. Among all the histogram parameters, the max frequency had the largest AUC value, which was 0.675. Histogram analysis of the ADC maps on the basis of the entire tumor volume can be useful in differentiating between histological grades for gastric cancer. 4 J. Magn. Reson. Imaging 2017;45:440-449. © 2016 International Society for Magnetic Resonance in Medicine.
Simulation of speckle patterns with pre-defined correlation distributions.
Song, Lipei; Zhou, Zhen; Wang, Xueyan; Zhao, Xing; Elson, Daniel S
2016-03-01
We put forward a method to easily generate a single or a sequence of fully developed speckle patterns with pre-defined correlation distribution by utilizing the principle of coherent imaging. The few-to-one mapping between the input correlation matrix and the correlation distribution between simulated speckle patterns is realized and there is a simple square relationship between the values of these two correlation coefficient sets. This method is demonstrated both theoretically and experimentally. The square relationship enables easy conversion from any desired correlation distribution. Since the input correlation distribution can be defined by a digital matrix or a gray-scale image acquired experimentally, this method provides a convenient way to simulate real speckle-related experiments and to evaluate data processing techniques.
Simulation of speckle patterns with pre-defined correlation distributions
Song, Lipei; Zhou, Zhen; Wang, Xueyan; Zhao, Xing; Elson, Daniel S.
2016-01-01
We put forward a method to easily generate a single or a sequence of fully developed speckle patterns with pre-defined correlation distribution by utilizing the principle of coherent imaging. The few-to-one mapping between the input correlation matrix and the correlation distribution between simulated speckle patterns is realized and there is a simple square relationship between the values of these two correlation coefficient sets. This method is demonstrated both theoretically and experimentally. The square relationship enables easy conversion from any desired correlation distribution. Since the input correlation distribution can be defined by a digital matrix or a gray-scale image acquired experimentally, this method provides a convenient way to simulate real speckle-related experiments and to evaluate data processing techniques. PMID:27231589
Yun, Jonghyun; Lee, Hyunyoung; Yang, Wonjae
2017-01-01
Objective Serum prostate-specific antigen (PSA) may be elevated in healthy men with systemic inflammation. We aimed to investigate the association between systemic inflammation markers and serum PSA in a healthy Korean population. Material and methods A cohort of 20,151 healthy native Korean men without prostate disease between the ages of 40 and 65 years who underwent medical checkups were studied from January 2007 to December 2013. Serum total PSA and serum C-reactive protein concentrations, neutrophil, lymphocyte, and platelet counts were determined. The neutrophil-lymphocyte ratio (NLR) and platelet-lymphocyte ratio (PLR) were calculated. We checked the correlation between systemic inflammation markers and PSA. Results Data obtained from 18,800 healthy men were analyzed. The mean age of the study subjects was 50.72±7.62 years and the mean NLR was 1.764±0.804. Correlation analysis after adjustment for age and body mass index (BMI) revealed that neutrophil count (coefficient = 0.028, p value <0.001), and NLR (coefficient = 0.027, p value <0.001) correlated with PSA. Multivariate analysis using the full model revealed that age, neutrophil count and NLR were positively correlated with PSA (p<0.001, 0.001, and 0.043 respectively). Multivariate analysis using a stepwise model revealed that age, neutrophil count and NLR were positively correlated with PSA (p<0.001, 0.001, and 0.040, respectively) and BMI was negatively correlated with PSA (p<0.001). Conclusion Systemic inflammation markers are useful with a serum PSA in a healthy Korean population. NLR in particular is significantly associated with serum PSA. PMID:28861299
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grewal, N.S.
(1) The proposed correlation of Equation (5) is recommended to predict the maximum value of heat transfer coefficient between a horzontal tube and a gas-solid fluidized bed of small particles under the conditions given. For high temperature applications (T/sub B/ > 600/sup 0/C), the radiative component is important and was estimated following Baskakov et al. (2) The proposed correlation of Equation (8) was found reliable to predict the existing data on the maximum value of heat transfer coefficient between a horizontal tube bundle and a gas-solid fluidized bed of small particles under the conditions given. At high temperatures, the radiativemore » component was estimated from the experimental data of Baskakov et al. (3) The correlation of Equation (8) predicted the GFETC data taken during the combustion of low-rank coal very well, when the contribution due to radiation was estimated following Baskakov et al. (4) The correlations proposed by Grewal and Bansal et al. were found to predict the data taken during low-rank coal combustion within +-25%, when the contribution due to radiation was included and estimated following Baskakov et al. (5) Finally, the correlations for large particles (anti d/sub p/ > 1mm) as proposed by Glicksman and Decker, Catipovic et al., Xavier and Davidson, and Zabrodsky et al. also predicted the data for low-rank coal fluidized bed combustor quite well, when the radiative component was estimated from the data of Baskakov et al. 64 references, 19 figures, 10 tables.« less
Relationship Between Muscle Strength Asymmetry and Body Sway in Older Adults.
Koda, Hitoshi; Kai, Yoshihiro; Murata, Shin; Osugi, Hironori; Anami, Kunihiko; Fukumoto, Takahiko; Imagita, Hidetaka
2018-05-31
The purpose of this study was to investigate the relationship between muscle strength asymmetry and body sway while walking. We studied 63 older adult women. Strong side and weak side of knee extension strength, toe grip strength, hand grip strength, and body sway while walking were measured. The relationship between muscle strength asymmetry for each muscle and body sway while walking was evaluated using Pearson's correlation coefficient. Regarding the muscles recognized to have significant correlation with body sway, the asymmetry cutoff value causing an increased sway was calculated. Toe grip strength asymmetry was significantly correlated with body sway. Toe grip strength asymmetry causing an increased body sway had a cutoff value of 23.5%. Our findings suggest toe grip strength asymmetry may be a target for improving gait stability.
Relationship Between Earthquake b-Values and Crustal Stresses in a Young Orogenic Belt
NASA Astrophysics Data System (ADS)
Wu, Yih-Min; Chen, Sean Kuanhsiang; Huang, Ting-Chung; Huang, Hsin-Hua; Chao, Wei-An; Koulakov, Ivan
2018-02-01
It has been reported that earthquake b-values decrease linearly with the differential stresses in the continental crust and subduction zones. Here we report a regression-derived relation between earthquake b-values and crustal stresses using the Anderson fault parameter (Aϕ) in a young orogenic belt of Taiwan. This regression relation is well established by using a large and complete earthquake catalog for Taiwan. The data set consists of b-values and Aϕ values derived from relocated earthquakes and focal mechanisms, respectively. Our results show that b-values decrease linearly with the Aϕ values at crustal depths with a high correlation coefficient of -0.9. Thus, b-values could be used as stress indicators for orogenic belts. However, the state of stress is relatively well correlated with the surface geological setting with respect to earthquake b-values in Taiwan. Temporal variations in the b-value could constitute one of the main reasons for the spatial heterogeneity of b-values. We therefore suggest that b-values could be highly sensitive to temporal stress variations.
Analytical determination of propeller performance degradation due to ice accretion
NASA Technical Reports Server (NTRS)
Miller, T. L.
1986-01-01
A computer code has been developed which is capable of computing propeller performance for clean, glaze, or rime iced propeller configurations, thereby providing a mechanism for determining the degree of performance degradation which results from a given icing encounter. The inviscid, incompressible flow field at each specified propeller radial location is first computed using the Theodorsen transformation method of conformal mapping. A droplet trajectory computation then calculates droplet impingement points and airfoil collection efficiency for each radial location, at which point several user-selectable empirical correlations are available for determining the aerodynamic penalities which arise due to the ice accretion. Propeller performance is finally computed using strip analysis for either the clean or iced propeller. In the iced mode, the differential thrust and torque coefficient equations are modified by the drag and lift coefficient increments due to ice to obtain the appropriate iced values. Comparison with available experimental propeller icing data shows good agreement in several cases. The code's capability to properly predict iced thrust coefficient, power coefficient, and propeller efficiency is shown to be dependent on the choice of empirical correlation employed as well as proper specification of radial icing extent.
Bogacheva, N V; Kriuchkov, A V; Darmov, I V; Vorob'ev, K A; Pechenkin, D V; Elagin, G D; Kolesnikiov, D P
2013-11-01
The article deals with experimental evaluation with flow cytofluorimetry technique of the level of cellular immunologic memory in persons vaccinated with plague and anthrax live dry vaccines. It is established that the introduction of plague and anthrax live dry vaccines into organism of vaccinated persons ignites immunologic rearrangement manifested by reliable increase of level of blood concentration of Th1-lymphocytes (immunologic memory cells) against the background of vaccination. The higher correlation coefficient is detected between leucocytes lysis coefficient and stimulation coefficient according blood concentration level of T-lymphocytes predominantly at the expense of Th1-lymphocytes. The values of stimulation coefficient were calculated for corresponding blood cells of vaccinated persons. This data testifies the effectiveness of application of vaccination against plague and anthrax.
NASA Astrophysics Data System (ADS)
Liu, W.; Xu, J.; Smith, A. K.; Yuan, W.
2017-12-01
Ground-based observations of the OH(9-4, 8-3, 6-2, 5-1, 3-0) band airglows over Xinglong, China (40°24'N, 117°35'E) from December 2011 to 2014 are used to calculate rotational temperatures. The temperatures are calculated using five commonly used Einstein coefficient datasets. The kinetic temperature from TIMED/SABER is completely independent of the OH rotational temperature. SABER temperatures are weighted vertically by weighting functions calculated for each emitting vibrational state from two SABER OH volume emission rate profiles. By comparing the ground-based OH rotational temperature with SABER's, five Einstein coefficient datasets are evaluated. The results show that temporal variations of the rotational temperatures are well correlated with SABER's; the linear correlation coefficients are higher than 0.72, but the slopes of the fit between the SABER and rotational temperatures are not equal to 1. The rotational temperatures calculated using each set of Einstein coefficients produce a different bias with respect to SABER; these are evaluated over each of vibrational levels to assess the best match. It is concluded that rotational temperatures determined using any of the available Einstein coefficient datasets have systematic errors. However, of the five sets of coefficients, the rotational temperature derived with the Langhoff et al.'s (1986) set is most consistent with SABER. In order to get a set of optimal Einstein coefficients for rotational temperature derivation, we derive the relative values from ground-based OH spectra and SABER temperatures statistically using three year data. The use of a standard set of Einstein coefficients will be beneficial for comparing rotational temperatures observed at different sites.
The 4-parameter Compressible Packing Model (CPM) including a critical cavity size ratio
NASA Astrophysics Data System (ADS)
Roquier, Gerard
2017-06-01
The 4-parameter Compressible Packing Model (CPM) has been developed to predict the packing density of mixtures constituted by bidisperse spherical particles. The four parameters are: the wall effect and the loosening effect coefficients, the compaction index and a critical cavity size ratio. The two geometrical interactions have been studied theoretically on the basis of a spherical cell centered on a secondary class bead. For the loosening effect, a critical cavity size ratio, below which a fine particle can be inserted into a small cavity created by touching coarser particles, is introduced. This is the only parameter which requires adaptation to extend the model to other types of particles. The 4-parameter CPM demonstrates its efficiency on frictionless glass beads (300 values), spherical particles numerically simulated (20 values), round natural particles (125 values) and crushed particles (335 values) with correlation coefficients equal to respectively 99.0%, 98.7%, 97.8%, 96.4% and mean deviations equal to respectively 0.007, 0.006, 0.007, 0.010.
The Attenuation of Correlation Coefficients: A Statistical Literacy Issue
ERIC Educational Resources Information Center
Trafimow, David
2016-01-01
Much of the science reported in the media depends on correlation coefficients. But the size of correlation coefficients depends, in part, on the reliability with which the correlated variables are measured. Understanding this is a statistical literacy issue.
Teodoro, P E; Torres, F E; Santos, A D; Corrêa, A M; Nascimento, M; Barroso, L M A; Ceccon, G
2016-05-09
The aim of this study was to evaluate the suitability of statistics as experimental precision degree measures for trials with cowpea (Vigna unguiculata L. Walp.) genotypes. Cowpea genotype yields were evaluated in 29 trials conducted in Brazil between 2005 and 2012. The genotypes were evaluated with a randomized block design with four replications. Ten statistics that were estimated for each trial were compared using descriptive statistics, Pearson correlations, and path analysis. According to the class limits established, selective accuracy and F-test values for genotype, heritability, and the coefficient of determination adequately estimated the degree of experimental precision. Using these statistics, 86.21% of the trials had adequate experimental precision. Selective accuracy and the F-test values for genotype, heritability, and the coefficient of determination were directly related to each other, and were more suitable than the coefficient of variation and the least significant difference (by the Tukey test) to evaluate experimental precision in trials with cowpea genotypes.
Santo, M V; Sansinena, M; Chirife, J; Zaritzky, N
2015-01-01
The use of mathematical models describing heat transfer during the freezing process is useful for the improvement of cryopreservation protocols. A widespread practice for cryopreservation of spermatozoa of domestic animal species consists of suspending plastic straws in nitrogen vapor before plunging into liquid nitrogen. Knowledge of surface heat transfer coefficient (h) is mandatory for computational modelling; however, h values for nitrogen vapor are not available. In the present study, surface heat transfer coefficients for plastic French straws immersed in nitrogen vapor over liquid nitrogen was determined; vertical and horizontal positions were considered. Heat transfer coefficients were determined from the measurement of time-temperature curves and from numerical solution of heat transfer partial differential equation under transient conditions using finite elements. The h values experimentally obtained for horizontal and vertically placed straws were compared to those calculated using correlations based on the Nusselt number for natural convection. For horizontal straws the average obtained value was h=12.5 ± 1.2 W m(2) K and in the case of vertical straws h=16 ± 2.48 W m(2) K. The numerical simulation validated against experimental measurements, combined with accurate h values provides a reliable tool for the prediction of freezing curves of semen-filled straws immersed in nitrogen vapor. The present study contributes to the understanding of the cryopreservation techniques for sperm freezing based on engineering concepts, improving the cooling protocols and the manipulation of the straws.
NASA Astrophysics Data System (ADS)
ul-Haq, Zia; Tariq, Salman; Ali, Muhammad
2017-10-01
An accurate knowledge is needed on the complex relation between atmospheric trace gasses and aerosol variability and their sources to explain trace gases-aerosols-climate interaction and next-generation modeling of climate change and air quality. In this regard, we have used tropospheric Nitrogen Dioxide (NO2), Aerosol Optical Depth (AOD) and Angstrom Exponent (AE) obtained from satellite-based Ozone Monitoring Instrument (OMI)/Aura and Moderate-Resolution Imaging Spectroradiometer (MODIS)/Aqua over South Asia. NO2-AOD correlation with coefficient r = 0.49 is determined over the landmass of South Asia during 2005-2015. Yearly mean NO2-AOD correlation over South Asia shows large variations ranging from r = 0.32 to 0.86 in 2008 and 2009, respectively. The highest correlation ( r = 0.66) is seen over eastern regions of Bangladesh and India, as well as adjoining areas of western Myanmar mostly linked to anthropogenic activities. A significant correlation ( r = 0.59) associated with natural causes is found over some parts of Sistan region, located at the borders of Iran, Pakistan and Afghanistan, and adjoining territory. We find significant positive correlations for monsoon and post-monsoon seasons with r = 0.50 and r = 0.61, respectively. A linear regression on the annual correlation coefficients data suggests that NO2-AOD correlation is strengthening with an increase of 12.9% over South Asia during the study period. The spatial distribution of data slopes reveals positive trends in NO2-AOD correlation over megacities Lahore, Dhaka, Mumbai and Kolkata linked to growing anthropogenic activities. Singrauli city (India) has the highest correlation ( r = 0.62) and 35% increase in correlation coefficient value per year. A negative correlation is observed for megacity Karachi ( r = -0.37) suggesting the non-commonality of NO2 and aerosols emission sources. AE has also been used to discuss its correlation with NO2 over the areas with dominance of fine-mode aerosols.
Model for estimating enteric methane emissions from United States dairy and feedlot cattle.
Kebreab, E; Johnson, K A; Archibeque, S L; Pape, D; Wirth, T
2008-10-01
Methane production from enteric fermentation in cattle is one of the major sources of anthropogenic greenhouse gas emission in the United States and worldwide. National estimates of methane emissions rely on mathematical models such as the one recommended by the Intergovernmental Panel for Climate Change (IPCC). Models used for prediction of methane emissions from cattle range from empirical to mechanistic with varying input requirements. Two empirical and 2 mechanistic models (COWPOLL and MOLLY) were evaluated for their prediction ability using individual cattle measurements. Model selection was based on mean square prediction error (MSPE), concordance correlation coefficient, and residuals vs. predicted values analyses. In dairy cattle, COWPOLL had the lowest root MSPE and greatest accuracy and precision of predicting methane emissions (correlation coefficient estimate = 0.75). The model simulated differences in diet more accurately than the other models, and the residuals vs. predicted value analysis showed no mean bias (P = 0.71). In feedlot cattle, MOLLY had the lowest root MSPE with almost all errors from random sources (correlation coefficient estimate = 0.69). The IPCC model also had good agreement with observed values, and no significant mean (P = 0.74) or linear bias (P = 0.11) was detected when residuals were plotted against predicted values. A fixed methane conversion factor (Ym) might be an easier alternative to diet-dependent variable Ym. Based on the results, the 2 mechanistic models were used to simulate methane emissions from representative US diets and were compared with the IPCC model. The average Ym in dairy cows was 5.63% of GE (range 3.78 to 7.43%) compared with 6.5% +/- 1% recommended by IPCC. In feedlot cattle, the average Ym was 3.88% (range 3.36 to 4.56%) compared with 3% +/- 1% recommended by IPCC. Based on our simulations, using IPCC values can result in an overestimate of about 12.5% and underestimate of emissions by about 9.8% for dairy and feedlot cattle, respectively. In addition to providing improved estimates of emissions based on diets, mechanistic models can be used to assess mitigation options such as changing source of carbohydrate or addition of fat to decrease methane, which is not possible with empirical models. We recommend national inventories use diet-specific Ym values predicted by mechanistic models to estimate methane emissions from cattle.
Direct-normal solar irradiance measurements and turbidity coefficient evaluation in central Spain.
NASA Astrophysics Data System (ADS)
Bllbao, Julia; Román, Roberto; Miguel, Argimiro
2013-04-01
In order to study the characteristics of solar direct radiation and the atmospheric turbidity in Valladolid, Spain, global, diffuse and direct irradiance data were recorded from May 2010 to December 2011, with a frequency of 10 minute. Measurements used were taken by the Energy and Atmosphere Group (http://www3.uva.es/renova), University of Valladolid, Spain at the Solar Radiometric Station (41,81°N 4.93°W, 840m a.s.l.) located on the Atmosphere Researcher Centre, Villalba de los Alcores, Valladolid, Spain. Sensors were installed in a Sun tracker (Solys 2, Kipp & Zonen) that blocks direct solar radiation using a shadow ball. The system consists of two pyranometers CMP-21 and one pyrheliometer CHP-1 (Kipp & Zonen), respectively. Based on these measurements, the characteristics of direct solar irradiance data were evaluated in order to know the main statistical parameters of the distribution. Angström turbidity coefficient values, beta, were estimated from direct solar irradiance and clear sky conditions. The beta coefficient values were obtained from MODIS satellite instrument, and the aerosol optical depth values, AOD(550nm), were evaluated. The turbidity coefficient beta shows seasonal variation, with higher values in summer (< 0.15) and lower in winter (< 0.05). It could be due to high temperatures in summer and less rainy days which would induce more atmospheric turbidity, increasing vertical convection and particles enhancement. The scattered graph of aerosol optical depth from satellite and the obtained from Angström expression has been plotted. The slope presents a value around the unity, 0.96, and the correlation coefficient shows a value of 0.6 . It was observed that turbidity coefficients increased in April 2011, and in order to now the origin the change, air masses trajectories, deduced from HYSPLIT model (http://ready.arl.noaa.gov/HYSPLIT.php) were studied. From the results it has been obtained that a situation of low pressures in the Atlantic Portuguese coast and high pressure in the North of Spain induced the movement of dust from Sahara desert into the Iberian Peninsula.
Matsumoto, Masatoshi; Inoue, Kazuo; Bowman, Robert; Kajii, Eiji
2010-08-01
Geographic and specialty maldistributions of physicians are political concerns in Japan. This study examined the associations of physician employment status with the number and geographic distribution of the physicians in each specialty in Japan, in comparison with the US. The number of physicians per unit population, proportion of clinic (Japan) or office (US) based physicians, and Gini coefficient of physicians against population were calculated in each of 20 specialties in Japan, and 21 specialties in the US. The geographic unit of Gini coefficient was municipality in Japan, and county in the US. Correlations among these three variables were also examined. The lower the proportion of clinic-based physicians was, the lower the number of physicians and the higher the Gini coefficient were in Japanese specialties, while there was no association between office-based rate and Gini coefficient in the US specialties. In radiology, anaesthesiology, emergency medicine, and pathology, Japanese clinic-based rates were less than one-tenth, and the numbers of physicians per unit population were less than half of the US values, and the Gini coefficients were substantially higher than the US values. Difficulty in being self-employed created low numbers in some specialties, and highly urban-biased distributions of these specialists in Japan. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.
Ito, Katsuyoshi; Hayashida, Minoru; Kanki, Akihiko; Yamamoto, Akira; Tamada, Tsutomu; Yoshida, Koji; Tanabe, Masahiro
2018-05-17
To evaluate dynamic changes in apparent diffusion coefficient (ADC) values of the kidney at different time points during the cardiac cycle using electrocardiographic (ECG)-triggered diffusion-weighted MR imaging in normal subjects, and to elucidate the differences in ADC values between the right and left kidneys during a cardiac cycle. The study was approved by our institutional review board and informed consent was obtained from subjects. Twenty healthy volunteers who underwent ECG-triggered diffusion-weighted MR imaging of the kidney were included. The differences in ADC values of each kidney during different cardiac phases were compared. Additionally, the differences in maximum and minimum ADC values between the right and left kidney were also evaluated. ADC values in the right and left kidney changed significantly during the cardiac cycle (P < 0.00001). Maximum and minimum ADC values during the cardiac cycle of the left kidney were significantly higher (P = 0.026 and 0.017, respectively) than those of the right kidney. Maximum ADC value in the left kidney had a significantly strong positive correlation with the left renal vein ratio (r = 0.83, P < 0.00001). In the right kidney, maximum ADC showed a weakly positive correlation with the diameter of the right renal vein (r = 0.45, P = 0.048). ADC values of the kidney obtained using ECG-triggered diffusion-weighted MR imaging change significantly during the cardiac cycle. Maximum (systolic) ADC during the cardiac cycle of the left kidney was significantly higher than that of the right kidney, probably due to the anatomical difference in the renal vein. Copyright © 2018 Elsevier Inc. All rights reserved.
A stochastic-dynamic model for global atmospheric mass field statistics
NASA Technical Reports Server (NTRS)
Ghil, M.; Balgovind, R.; Kalnay-Rivas, E.
1981-01-01
A model that yields the spatial correlation structure of atmospheric mass field forecast errors was developed. The model is governed by the potential vorticity equation forced by random noise. Expansion in spherical harmonics and correlation function was computed analytically using the expansion coefficients. The finite difference equivalent was solved using a fast Poisson solver and the correlation function was computed using stratified sampling of the individual realization of F(omega) and hence of phi(omega). A higher order equation for gamma was derived and solved directly in finite differences by two successive applications of the fast Poisson solver. The methods were compared for accuracy and efficiency and the third method was chosen as clearly superior. The results agree well with the latitude dependence of observed atmospheric correlation data. The value of the parameter c sub o which gives the best fit to the data is close to the value expected from dynamical considerations.
Sample Size Estimation in Cluster Randomized Educational Trials: An Empirical Bayes Approach
ERIC Educational Resources Information Center
Rotondi, Michael A.; Donner, Allan
2009-01-01
The educational field has now accumulated an extensive literature reporting on values of the intraclass correlation coefficient, a parameter essential to determining the required size of a planned cluster randomized trial. We propose here a simple simulation-based approach including all relevant information that can facilitate this task. An…
Meyer, Hans Jonas; Leifels, Leonard; Schob, Stefan; Garnov, Nikita; Surov, Alexey
2018-01-01
Nowadays, multiparametric investigations of head and neck squamous cell carcinoma (HNSCC) are established. These approaches can better characterize tumor biology and behavior. Diffusion weighted imaging (DWI) can by means of apparent diffusion coefficient (ADC) quantitatively characterize different tissue compartments. Dynamic contrast-enhanced magnetic resonance imaging (DCE MRI) reflects perfusion and vascularization of tissues. Recently, a novel approach of data acquisition, namely histogram analysis of different images is a novel diagnostic approach, which can provide more information of tissue heterogeneity. The purpose of this study was to analyze possible associations between DWI, and DCE parameters derived from histogram analysis in patients with HNSCC. Overall, 34 patients, 9 women and 25 men, mean age, 56.7±10.2years, with different HNSCC were involved in the study. DWI was obtained by using of an axial echo planar imaging sequence with b-values of 0 and 800s/mm 2 . Dynamic T1w DCE sequence after intravenous application of contrast medium was performed for estimation of the following perfusion parameters: volume transfer constant (K trans ), volume of the extravascular extracellular leakage space (Ve), and diffusion of contrast medium from the extravascular extracellular leakage space back to the plasma (Kep). Both ADC and perfusion parameters maps were processed offline in DICOM format with custom-made Matlab-based application. Thereafter, polygonal ROIs were manually drawn on the transferred maps on each slice. For every parameter, mean, maximal, minimal, and median values, as well percentiles 10th, 25th, 75th, 90th, kurtosis, skewness, and entropy were estimated. Сorrelation analysis identified multiple statistically significant correlations between the investigated parameters. Ve related parameters correlated well with different ADC values. Especially, percentiles 10 and 75, mode, and median values showed stronger correlations in comparison to other parameters. Thereby, the calculated correlation coefficients ranged from 0.62 to 0.69. Furthermore, K trans related parameters showed multiple slightly to moderate significant correlations with different ADC values. Strongest correlations were identified between ADC P75 and K trans min (p=0.58, P=0.0007), and ADC P75 and K trans P10 (p=0.56, P=0.001). Only four K ep related parameters correlated statistically significant with ADC fractions. Strongest correlation was found between K ep max and ADC mode (p=-0.47, P=0.008). Multiple statistically significant correlations between, DWI and DCE MRI parameters derived from histogram analysis were identified in HNSCC. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jefferson, A.; Hageman, D.; Morrow, H.
Long-term measurements of changes in the aerosol scattering coefficient hygroscopic growth at the U.S. Department of Energy Southern Great Plains site provide information on the seasonal as well as size and chemical dependence of aerosol hygroscopic growth. Annual average sub 10 um fRH values (the ratio of aerosol scattering at 85%/40% RH) were 1.75 and 1.87 for the gamma and kappa fit algorithms, respectively. The study found higher growth rates in the winter and spring seasons that correlated with high aerosol nitrate mass fraction. FRH, exhibited strong, but differing correlations with the scattering Ångström exponent and backscatter fraction, two opticalmore » size-dependent parameters. The aerosol organic fraction had a strong influence, with fRH decreasing with increases in the organic mass fraction and absorption Ångström exponent and increasing with the aerosol single scatter albedo. Uncertainty analysis if the fit algorithms revealed high uncertainty at low scattering coefficients and slight increases in uncertainty at high RH and fit parameters values.« less
Paseiro-Cerrato, Rafael; Tongchat, Chinawat; Franz, Roland
2016-05-01
This study evaluated the influence of parameters such as temperature and type of low-density polyethylene (LDPE) film on the log Kp/f values of seven model migrants in food simulants. Two different types of LDPE films contaminated by extrusion and immersion were placed in contact with three food simulants including 20% ethanol, 50% ethanol and olive oil under several time-temperature conditions. Results suggest that most log Kp/f values are little affected by these parameters in this study. In addition, the relation between log Kp/f and log Po/w was established for each food simulant and regression lines, as well as correlation coefficients, were calculated. Correlations were compared with data from real foodstuffs. Data presented in this study could be valuable in assigning certain foods to particular food simulants as well as predicting the mass transfer of potential migrants into different types of food or food simulants, avoiding tedious and expensive laboratory analysis. The results could be especially useful for regulatory agencies as well as for the food industry.
Influence of leucite content on slow crack growth of dental porcelains.
Cesar, Paulo F; Soki, Fabiana N; Yoshimura, Humberto N; Gonzaga, Carla C; Styopkin, Victor
2008-08-01
To determine the stress corrosion susceptibility coefficient, n, of seven dental porcelains (A: Ceramco I; B: Ceramco-II; C: Ceramco-III; D: d.Sign; E: Cerabien; F: Vitadur-Alpha; and G: Ultropaline) after aging in air or artificial saliva, and correlate results with leucite content (LC). Bars were fired according to manufacturers' instructions and polished before induction of cracks by a Vickers indenter (19.6N, 20s). Four specimens were stored in air/room temperature, and three in saliva/37 degrees C. Five indentations were made per specimen and crack lengths measured at the following times: approximately 0; 1; 3; 10; 30; 100; 300; 1000 and 3000 h. The stress corrosion coefficient n was calculated by linear regression analysis after plotting crack length as a function of time, considering that the slope of the curve was [2/(3n+2)]. Microstructural analysis was performed to determine LC. LC of the porcelains were 22% (A and B); 6% (C); 15% (D); 0% (E and F); and 13% (G). Except for porcelains A and D, all materials showed a decrease in their n values when stored in artificial saliva. However, the decrease was more pronounced for porcelains B, F, and G. Ranking of materials varied according to storage media (in air, porcelain G showed higher n compared to A, while in saliva both showed similar coefficients). No correlation was found between n values and LC in air or saliva. Storage media influenced the n value obtained for most of the materials. LC did not affect resistance to slow crack growth regardless of the test environment.
Use of a W-band polarimeter to measure microphysical characteristics of clouds
NASA Astrophysics Data System (ADS)
Galloway, John Charles
1997-08-01
This dissertation presents W-Band measurements of the copolar correlation co-efficient and Doppler spectrum taken from the University of Wyoming King Air research airplane. These measurements demonstrate the utility of making W-Band polarimetric and Doppler spectrum measurements from an airborne platform in investigations of cloud microphysical properties. Comparison of copolar correlation coefficient measurements with aircraft in situ probe measurements verifies that polarimetric measurements indicate phase transitions, and hydrometeor alignment in ice clouds. Melting layers in clouds were measured by the W-Band system on board the King Air during 1992 and 1994. Both measurements established the use of the linear depolarization ratio, LDR, to locate the melting layer using an airborne W-Band system. The measurement during 1994 allowed direct comparison of the magnitude of the copolar correlation coefficient with the values of LDR. The relation between the measurements corresponds with a predicted relationship between the two parameters for observation of particles exhibiting isotropy in the plane of polarization. Measurements of needle crystals at horizontal and vertical incidence provided further evidence that the copolar correlation coefficient values agreed with the expected response from hydrometeors possessing a preferred alignment for the side looking case, and hydrometeors without a preferred alignment for the vertical incidence case. Observation of significant specific differential phase at vertical incidence, the first reported at W-Band, corresponded to a significant increase in differential reflectivity overhead, which was most likely produced by hydrometeor alignment driven by cloud electrification. Comparison of the drop size distributions estimated using the Doppler spectra with those measured by the wingtip probes on the King Air reveals that the radar system is better suited under some liquid cloud conditions to provide microphysical measurements of the cloud or precipitation than the probes. The radiometric calibration of the radar system determines the accuracy of the drop size distribution estimate. The results presented here indicate that the procedure used to absolutely calibrate the W-Band radar system successfully characterized the reflectivity measurements to the extent required to obtain close correspondence between the radar and probe measurements of the drop size distribution.
Correlation of laboratory and production freeze drying cycles.
Kuu, Wei Y; Hardwick, Lisa M; Akers, Michael J
2005-09-30
The purpose of this study was to develop the correlation of cycle parameters between a laboratory and a production freeze-dryer. With the established correlation, key cycle parameters obtained using a laboratory dryer may be converted to those for a production dryer with minimal experimental efforts. In order to develop the correlation, it was important to consider the contributions from the following freeze-drying components: (1) the dryer, (2) the vial, and (3) the formulation. The critical parameters for the dryer are the shelf heat transfer coefficient and shelf surface radiation emissivity. The critical parameters for the vial are the vial bottom heat transfer coefficients (the contact parameter Kcs and separation distance lv), and vial top heat transfer coefficient. The critical parameter of the formulation is the dry layer mass transfer coefficient. The above heat and mass transfer coefficients were determined by freeze-drying experiments in conjunction with mathematical modeling. With the obtained heat and mass transfer coefficients, the maximum product temperature, Tbmax, during primary drying was simulated using a primary drying subroutine as a function of the shelf temperature and chamber pressure. The required shelf temperature and chamber pressure, in order to perform a successful cycle run without product collapse, were then simulated based on the resulting values of Tbmax. The established correlation approach was demonstrated by the primary drying of the model formulation 5% mannitol solution. The cycle runs were performed using a LyoStar dryer as the laboratory dryer and a BOC Edwards dryer as the production dryer. The determined normalized dried layer mass transfer resistance for 5% mannitol is expressed as RpN=0.7313+17.19l, where l is the receding dry layer thickness. After demonstrating the correlation approach using the model formulation 5% mannitol, a practical comparison study was performed for the actual product, the lactate dehydrogenase (LDH) formulation. The determined normalized dried layer mass transfer resistance for the LDH formulation is expressed as RpN=4.344+10.85l. The operational templates Tbmax and primary drying time were also generated by simulation. The cycle run for the LDH formulation using the Edwards production dryer verified that the cycle developed in a laboratory freeze-dryer was transferable at the production scale.
Imaeda, Toshihiko; Uchiyama, Shigeharu; Wada, Takuro; Okinaga, Shuji; Sawaizumi, Takuya; Omokawa, Shohei; Momose, Toshimitsu; Moritomo, Hisao; Gotani, Hiroyuki; Abe, Yukio; Nishida, Jun; Kanaya, Fuminori
2010-07-01
The Patient-Rated Wrist Evaluation is a regionspecific, self-administered questionnaire consisting of a pain scale (PRWE-P) and a functional scale (PRWE-F), with the latter consisting of specific function (PRWE-SF) and usual function (PRWE-UF). The PRWE was cross-culturally adapted from the original English version by the Impairment Evaluation Committee, Japanese Society for Surgery of the Hand (JSSH). The purpose of this study was to test the reliability, validity, and responsiveness of the Japanese version of PRWE (PRWE-J). A consecutive series of 117 patients with wrist disorders completed the PRWE-J, the JSSH version of the Disabilities of the Arm, Shoulder, and Hand (DASH-JSSH) questionnaire and the 36-Item Short-Form Health Survey (SF-36). Of the 117 patients, 71 were reassessed for test-retest reliability 1 or 2 weeks later. Reliability was investigated by reproducibility and internal consistency. To analyze the validity, a factor analysis (principal axis factoring) of PRWE-J and correlation coefficients between PRWE-J and DASH-JSSH were obtained. Responsiveness was examined by calculating the standardized response mean (SRM) (mean change/SD) and effect size (mean change/SD of baseline value) after open surgery in 50 patients. Cronbach's alpha coefficients for PRWE-P, PRWE-F, and PRWE were 0.90, 0.95, and 0.95, respectively. The intraclass correlation coefficients (ICCs) for the same were 0.86, 0.93, and 0.92, respectively. Unidimensionality of PRWE-P was con-firmed. Bidimensionality of PRWE-F was confirmed and separated clearly into PRWE-SF and PRWE-UF. The correlation coefficients between PRWE-P and PRWE-F or DASH-JSSH were 0.63 or 0.63, respectively. The correlation coefficient between PRWE-F and DASH-JSSH was 0.80. The correlation coefficients between DASH-JSSH and PRWE-SF or PRWE-UF were 0.76 or 0.73, respectively. Moderate correlation was observed in "physical functioning" for SF-36 and PRWE-SF (r = -0.46), PRWE-F (r = -0.46), or PRWE (r = -0.46). The SRMs/effect sizes of PRWE-P, PRWE-F, or PRWE were respectively excellent: 1.7/2.2, 1.2/1.3, 1.6/1.9. The PRWE-J has evaluation capacities equivalent to those of the original PRWE.
Correlation Between Soil Moisture and Dust Emissions: An Investigation for Global Climate Modeling
NASA Technical Reports Server (NTRS)
Fredrickson, Carley; Tan, Qian
2017-01-01
This work is using the newly available NASA SMAP soil moisture measurement data to evaluate its impact on the atmospheric dust emissions. Dust is an important component of atmospheric aerosols, which affects both climate and air quality. In this work, we focused on semi-desert regions, where dust emissions show seasonal variations due to soil moisture changes, i.e. in Sahel of Africa. We first identified three Aerosol Robotic Network (AERONET) sites in the Sahel (IER_Cinzana, Banizoumbou, and Zinder_Airport). We then utilized measurements of aerosol optical depth (AOD), fine mode fraction, size distribution, and single-scattering albedo and its wave-length dependence to select dust plumes from the available measurements We matched the latitude and longitude of the AERONET station to the corresponding SMAP data cell in the years 2015 and 2016, and calculated their correlation coefficient. Additionally, we looked at the correlation coefficient with a three-day and a five-day shift to check the impact of soil moisture on dust plumes with some time delay. Due to the arid nature of Banizoumbou and Zinder_Airport, no correlation was found to exist between local soil moisture and dust aerosol load. While IER_Cinzana had soil moisture levels above the satellite threshold of 0.02cm3/cm3, R-value approaching zero indicated no presence of a correlation. On the other hand, Ilorin demonstrated a significant negative correlation between aerosol optical depth and soil moisture. When isolating the analysis to Ilorin's dry season, a negative correlation of -0.593 was the largest dust-isolated R-value recorded, suggesting that soil moisture is driven the dust emission in this semi-desert region during transitional season.
The Edematous and Erythematous Airway Does Not Denote Pathologic Gastroesophageal Reflux.
Rosen, Rachel; Mitchell, Paul D; Amirault, Janine; Amin, Manali; Watters, Karen; Rahbar, Reza
2017-04-01
To determine if the reflux finding score (RFS), a validated score for airway inflammation, correlates with gastroesophageal reflux measured by multichannel intraluminal impedance (MII) testing, endoscopy, and quality of life scores. We performed a prospective, cross-sectional cohort study of 77 children with chronic cough undergoing direct laryngoscopy and bronchoscopy, esophagogastroduodenoscopy, and MII testing with pH (pH-MII) between 2006 and 2011. Airway examinations were videotaped and reviewed by 3 blinded otolaryngologists each of whom assigned RFS to the airways. RFS were compared with the results of reflux testing (endoscopy, MII, symptom scores). An intraclass correlation coefficient was calculated for the degree of agreement between otolaryngologists' RFS. Receiver operating characteristic curves were created to determine the sensitivity of the RFS. Spearman correlation was calculated between the RFS and reflux measurements by pH-MII. The mean ± SD RFS was 12 ± 4. There was no correlation between pH-MII variables and mean RFS (|r| < 0.15). The concordance correlation coefficient for RFS between otolaryngologists was low (intraclass correlation coefficient = 0.32). Using pH-metry as a gold standard, the positive predictive value for the RFS was 29%. Using MII as the gold standard, the positive predictive value for the RFS was 40%. There was no difference in the mean RFS in patients with (12 ± 4) and without (12 ± 3) esophagitis (P = .9). There was no correlation between RFS and quality of life scores (|r| < 0.15, P > .3). The RFS cannot predict pathologic gastroesophageal reflux and an airway examination should not be used as a basis for prescribing gastroesophageal reflux therapies. Copyright © 2016. Published by Elsevier Inc.
Liszewski, M.J.; Rosentreter, J.J.; Miller, Karl E.; Bartholomay, R.C.
2000-01-01
The U.S. Geological Survey and Idaho State University, in cooperation with the U.S. Department of Energy, conducted a study to determine strontium distribution coefficients (K(d)s) of surficial sediments at the Idaho National Engineering and Environmental Laboratory (INEEL). Batch experiments using synthesized aqueous solutions were used to determine K(d)s, which describe the distribution of a solute between the solution and solid phase, of 20 surficial-sediment samples from the INEEL. The K(d)s for the 20 surficial-sediment samples ranged from 36 to 275 ml/g. Many properties of both the synthesized aqueous solutions and sediments used in the experiments also were determined. Solution properties determined were initial and equilibrium concentrations of calcium, magnesium, and strontium, pH and specific conductance, and initial concentrations of potassium and sodium. Sediment properties determined were grain-size distribution, bulk mineralogy, whole-rock major-oxide and strontium and barium concentrations, and Brunauer-Emmett-Teller (BET) surface area. Solution and sediment properties were correlated with strontium K(d)s of the 20 surficial sediments using Pearson correlation coefficients. Solution properties with the strongest correlations with strontium K(d)s were equilibrium pH and equilibrium calcium concentration correlation coefficients, 0.6598 and -0.6518, respectively. Sediment properties with the strongest correlations with strontium K(d)s were manganese oxide (MnO), BET surface area, and the >4.75-mm-grain-size fraction correlation coefficients, 0.7054, 0.7022, and -0.6660, respectively. Effects of solution properties on strontium K(d)s were interpreted as being due to competition among similarly charged and sized cations in solution for strontium-sorption sites; effects of sediment properties on strontium K(d)s were interpreted as being surface-area related. Multivariate analyses of these solution and sediment properties resulted in r2 values of 0.8071 when all five properties were used and 0.8043 when three properties, equilibrium pH, MnO, and BET surface area, were used.
Validation study of an electronic method of condensed outcomes tools reporting in orthopaedics.
Farr, Jack; Verma, Nikhil; Cole, Brian J
2013-12-01
Patient-reported outcomes (PRO) instruments are a vital source of data for evaluating the efficacy of medical treatments. Historically, outcomes instruments have been designed, validated, and implemented as paper-based questionnaires. The collection of paper-based outcomes information may result in patients becoming fatigued as they respond to redundant questions. This problem is exacerbated when multiple PRO measures are provided to a single patient. In addition, the management and analysis of data collected in paper format involves labor-intensive processes to score and render the data analyzable. Computer-based outcomes systems have the potential to mitigate these problems by reformatting multiple outcomes tools into a single, user-friendly tool.The study aimed to determine whether the electronic outcomes system presented produces results comparable with the test-retest correlations reported for the corresponding orthopedic paper-based outcomes instruments.The study is designed as a crossover study based on consecutive orthopaedic patients arriving at one of two designated orthopedic knee clinics.Patients were assigned to complete either a paper or a computer-administered questionnaire based on a similar set of questions (Knee injury and Osteoarthritis Outcome Score, International Knee Documentation Committee form, 36-Item Short Form survey, version 1, Lysholm Knee Scoring Scale). Each patient completed the same surveys using the other instrument, so that all patients had completed both paper and electronic versions. Correlations between the results from the two modes were studied and compared with test-retest data from the original validation studies.The original validation studies established test-retest reliability by computing correlation coefficients for two administrations of the paper instrument. Those correlation coefficients were all in the range of 0.7 to 0.9, which was deemed satisfactory. The present study computed correlation coefficients between the paper and electronic modes of administration. These correlation coefficients demonstrated similar results with an overall value of 0.86.On the basis of the correlation coefficients, the electronic application of commonly used knee outcome scores compare variably to the traditional paper variants with a high rate of test-retest correlation. This equivalence supports the use of the condensed electronic outcomes system and validates comparison of scores between electronic and paper modes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Development of a label-free immunosensor system for detecting plasma cortisol levels in fish.
Wu, Haiyun; Ohnuki, Hitoshi; Hibi, Kyoko; Ren, Huifeng; Endo, Hideaki
2016-02-01
Fishes display a wide variation in their physiological responses to stress, which is clearly evident in the plasma corticosteroid changes, chiefly cortisol levels in fish. In the present study, we describe a novel label-free immunosensor for detecting plasma cortisol levels. The method is based on immunologic reactions and amperometric measurement using cyclic voltammetry. For the immobilization of the antibody on the surface of sensing electrode, we used a self-assembled monolayer of thiol-containing compounds. Using this electrode, we detect the CV signal change caused by the generation of antigen-antibody complex. The immunosensor showed a response to cortisol levels, and the anodic peak value linearly decreased with a correlation coefficient of 0.990 in diluted plasma. The specificity of the label-free immunosensor system was investigated using other steroid hormones, such as 17α, 20β-dihydroxy-4-pregnen-3-one, progesterone, estriol, estradiol, and testosterone. The specific detection of cortisol was suggested by a minimal change from -0.32 to 0.51 μA in the anodic peak value of the other steroid hormones. The sensor system was used to determine the plasma cortisol levels in Nile tilapia (Oreochromis niloticus), and the results were compared with those of the same samples determined using the conventional method (ELISA). A good correlation was obtained between values determined using both methods (correlation coefficient 0.993). These findings suggest that the proposed label-free immunosensor could be useful for rapid and convenient analysis of cortisol levels in fish plasma samples.
Roth, Michal
2016-12-06
High-pressure phase behavior of systems containing water, carbon dioxide and organics has been important in several environment- and energy-related fields including carbon capture and storage, CO 2 sequestration and CO 2 -assisted enhanced oil recovery. Here, partition coefficients (K-factors) of organic solutes between water and supercritical carbon dioxide have been correlated with extended linear solvation energy relationships (LSERs). In addition to the Abraham molecular descriptors of the solutes, the explanatory variables also include the logarithm of solute vapor pressure, the solubility parameters of carbon dioxide and water, and the internal pressure of water. This is the first attempt to include also the properties of water as explanatory variables in LSER correlations of K-factor data in CO 2 -water-organic systems. Increasing values of the solute hydrogen bond acidity, the solute hydrogen bond basicity, the solute dipolarity/polarizability, the internal pressure of water and the solubility parameter of water all tend to reduce the K-factor, that is, to favor the solute partitioning to the water-rich phase. On the contrary, increasing values of the solute characteristic volume, the solute vapor pressure and the solubility parameter of CO 2 tend to raise the K-factor, that is, to favor the solute partitioning to the CO 2 -rich phase.
Urticaceae pollen concentration in the atmosphere of North Western Spain.
Vega-Maray, Ana Maria; Valencia-Barrera, Rosa; Fernandez-Gonzalez, Delia; Fraile, Roberto
2003-01-01
Plants of the Urticaceae family can develop into a pest on soils enriched with nitrogen. Urticaceae pollen is a biohazard because it elicits severe pollinosis. Pollen grains were sampled by using a Lanzoni seven-day-recording trap from February 1995-December 2000 in the atmosphere of the city of Ponferrada (Leon, North Western Spain). The Spearman test was used to analyse the statistical correlation between Urticaceae pollen and certain meteorological factors in different main pollination periods. Maximum values are reached in June and July, minimum levels are recorded in January and December. The parameters bearing the greatest positive influence on the occurrence of Urticaceae pollen grains are: temperature (maximum, minimum and mean), humidity (absolute, wet-bulb temperature, dew point and mixing ratio) and south western wind direction; negative parameters are: relative humidity, rainfall and period without wind. The highest correlation coefficients were obtained with temperature and wet-bulb. Absolute humidity and wet-bulb temperature yielded better correlation than relative humidity; hence, these two parameters must be included in this type of study. The use of one main pollination period or another in statistical analysis has an influence on the coefficient value. The behaviour of the pollen grains in the atmosphere during the year also influences the results.
Band selection method based on spectrum difference in targets of interest in hyperspectral imagery
NASA Astrophysics Data System (ADS)
Zhang, Xiaohan; Yang, Guang; Yang, Yongbo; Huang, Junhua
2016-10-01
While hyperspectral data shares rich spectrum information, it has numbers of bands with high correlation coefficients, causing great data redundancy. A reasonable band selection is important for subsequent processing. Bands with large amount of information and low correlation should be selected. On this basis, according to the needs of target detection applications, the spectral characteristics of the objects of interest are taken into consideration in this paper, and a new method based on spectrum difference is proposed. Firstly, according to the spectrum differences of targets of interest, a difference matrix which represents the different spectral reflectance of different targets in different bands is structured. By setting a threshold, the bands satisfying the conditions would be left, constituting a subset of bands. Then, the correlation coefficients between bands are calculated and correlation matrix is given. According to the size of the correlation coefficient, the bands can be set into several groups. At last, the conception of normalized variance is used on behalf of the information content of each band. The bands are sorted by the value of its normalized variance. Set needing number of bands, and the optimum band combination solution can be get by these three steps. This method retains the greatest degree of difference between the target of interest and is easy to achieve by computer automatically. Besides, false color image synthesis experiment is carried out using the bands selected by this method as well as other 3 methods to show the performance of method in this paper.
Soares, Gabriel Porto; Klein, Carlos Henrique; Silva, Nelson Albuquerque de Souza e; de Oliveira, Glaucia Maria Moraes
2016-01-01
Background Diseases of the circulatory system (DCS) are the major cause of death in Brazil and worldwide. Objective To correlate the compensated and adjusted mortality rates due to DCS in the Rio de Janeiro State municipalities between 1979 and 2010 with the Human Development Index (HDI) from 1970 onwards. Methods Population and death data were obtained in DATASUS/MS database. Mortality rates due to ischemic heart diseases (IHD), cerebrovascular diseases (CBVD) and DCS adjusted by using the direct method and compensated for ill-defined causes. The HDI data were obtained at the Brazilian Institute of Applied Research in Economics. The mortality rates and HDI values were correlated by estimating Pearson linear coefficients. The correlation coefficients between the mortality rates of census years 1991, 2000 and 2010 and HDI data of census years 1970, 1980 and 1991 were calculated with discrepancy of two demographic censuses. The linear regression coefficients were estimated with disease as the dependent variable and HDI as the independent variable. Results In recent decades, there was a reduction in mortality due to DCS in all Rio de Janeiro State municipalities, mainly because of the decline in mortality due to CBVD, which was preceded by an elevation in HDI. There was a strong correlation between the socioeconomic indicator and mortality rates. Conclusion The HDI progression showed a strong correlation with the decline in mortality due to DCS, signaling to the relevance of improvements in life conditions. PMID:27849263
Soares, Gabriel Porto; Klein, Carlos Henrique; Silva, Nelson Albuquerque de Souza E; Oliveira, Glaucia Maria Moraes de
2016-10-01
Diseases of the circulatory system (DCS) are the major cause of death in Brazil and worldwide. To correlate the compensated and adjusted mortality rates due to DCS in the Rio de Janeiro State municipalities between 1979 and 2010 with the Human Development Index (HDI) from 1970 onwards. Population and death data were obtained in DATASUS/MS database. Mortality rates due to ischemic heart diseases (IHD), cerebrovascular diseases (CBVD) and DCS adjusted by using the direct method and compensated for ill-defined causes. The HDI data were obtained at the Brazilian Institute of Applied Research in Economics. The mortality rates and HDI values were correlated by estimating Pearson linear coefficients. The correlation coefficients between the mortality rates of census years 1991, 2000 and 2010 and HDI data of census years 1970, 1980 and 1991 were calculated with discrepancy of two demographic censuses. The linear regression coefficients were estimated with disease as the dependent variable and HDI as the independent variable. In recent decades, there was a reduction in mortality due to DCS in all Rio de Janeiro State municipalities, mainly because of the decline in mortality due to CBVD, which was preceded by an elevation in HDI. There was a strong correlation between the socioeconomic indicator and mortality rates. The HDI progression showed a strong correlation with the decline in mortality due to DCS, signaling to the relevance of improvements in life conditions.
The validity of an assessment of maximum angular velocity of knee extension (KE) using a gyroscope.
Arai, Takeshi; Obuchi, Shuichi; Shiba, Yoshitaka; Omuro, Kazuya; Inaba, Yasuko; Kojima, Motonaga
2012-01-01
Although it is more important to assess the muscular power of the lower extremities than the strength, no simplified method for doing so has been found. The aim of this study was to assess the validity of the assessment of the angular velocity of KE using a gyroscope. Participants included 105 community-dwelling older people (55 women, 50 men, age ± standard deviation (SD) 75±5.3). Pearson correlation coefficients and Spearman rank-correlation coefficients were used to examine the relationships between the angular velocity of KE and functional performance measurements, a self-efficacy scale and health-related quality of life (HRQOL). The data from the gyroscope were significantly correlated with some physical functions such as muscle strength (r=0.304, p<0.01), and walking velocity (r=0.543, p<0.001). In addition, the joint angular velocity was significantly correlated with self-efficacy (r=0.219-0.329, p<0.01-0.05) and HRQOL (r=0.207-0.359, p<0.01-0.05). The absolute value of the correlation coefficient of angular velocity tended to be greater than that of the muscle strength for mobility functions such as walking velocity and the timed-up-and-go (TUG) test. In conclusion, it was found that the assessment of the angular velocity of the knee joint using a gyroscope could be a feasible and meaningful measurement in the geriatrics field. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Comparison of Dst Forecast Models for Intense Geomagnetic Storms
NASA Technical Reports Server (NTRS)
Ji, Eun-Young; Moon, Y.-J.; Gopalswamy, N.; Lee, D.-H.
2012-01-01
We have compared six disturbance storm time (Dst) forecast models using 63 intense geomagnetic storms (Dst <=100 nT) that occurred from 1998 to 2006. For comparison, we estimated linear correlation coefficients and RMS errors between the observed Dst data and the predicted Dst during the geomagnetic storm period as well as the difference of the value of minimum Dst (Delta Dst(sub min)) and the difference in the absolute value of Dst minimum time (Delta t(sub Dst)) between the observed and the predicted. As a result, we found that the model by Temerin and Li gives the best prediction for all parameters when all 63 events are considered. The model gives the average values: the linear correlation coefficient of 0.94, the RMS error of 14.8 nT, the Delta Dst(sub min) of 7.7 nT, and the absolute value of Delta t(sub Dst) of 1.5 hour. For further comparison, we classified the storm events into two groups according to the magnitude of Dst. We found that the model of Temerin and Lee is better than the other models for the events having 100 <= Dst < 200 nT, and three recent models (the model of Wang et al., the model of Temerin and Li, and the model of Boynton et al.) are better than the other three models for the events having Dst <= 200 nT.
NASA Astrophysics Data System (ADS)
Piretzidis, D.; Sra, G.; Sideris, M. G.
2016-12-01
This study explores new methods for identifying correlation errors in harmonic coefficients derived from monthly solutions of the Gravity Recovery and Climate Experiment (GRACE) satellite mission using pattern recognition and neural network algorithms. These correlation errors are evidenced in the differences between monthly solutions and can be suppressed using a de-correlation filter. In all studies so far, the implementation of the de-correlation filter starts from a specific minimum order (i.e., 11 for RL04 and 38 for RL05) until the maximum order of the monthly solution examined. This implementation method has two disadvantages, namely, the omission of filtering correlated coefficients of order less than the minimum order and the filtering of uncorrelated coefficients of order higher than the minimum order. In the first case, the filtered solution is not completely free of correlated errors, whereas the second case results in a monthly solution that suffers from loss of geophysical signal. In the present study, a new method of implementing the de-correlation filter is suggested, by identifying and filtering only the coefficients that show indications of high correlation. Several numerical and geometric properties of the harmonic coefficient series of all orders are examined. Extreme cases of both correlated and uncorrelated coefficients are selected, and their corresponding properties are used to train a two-layer feed-forward neural network. The objective of the neural network is to identify and quantify the correlation by providing the probability of an order of coefficients to be correlated. Results show good performance of the neural network, both in the validation stage of the training procedure and in the subsequent use of the trained network to classify independent coefficients. The neural network is also capable of identifying correlated coefficients even when a small number of training samples and neurons are used (e.g.,100 and 10, respectively).
Validity and Reliability of a Portable Balance Tracking System, BTrackS, in Older Adults.
Levy, Susan S; Thralls, Katie J; Kviatkovsky, Shiloah A
Falls are the leading cause of disability, injury, hospital admission, and injury-related death among older adults. Balance limitations have consistently been identified as predictors of falls and increased fall risk. Field measures of balance are limited by issues of subjectivity, ceiling effects, and low sensitivity to change. The gold standard for measuring balance is the force plate; however, its field use is untenable due to high cost and lack of portability. Thus, a critical need is observed for valid objective field measures of balance to accurately assess balance and identify limitations over time. The purpose of this study was to examine the concurrent validity and 3-day test-retest reliability of Balance Tracking System (BTrackS) in community-dwelling older adults. Minimal detectable change values were also calculated to reflect changes in balance beyond measurement error. Postural sway data were collected from community-dwelling older adults (N = 49, mean [SD] age = 71.3 [7.3] years) with a force plate and BTrackS in multitrial eyes open (EO) and eyes closed (EC) static balance conditions. Force sensors transmitted BTrackS data via a USB to a computer running custom software. Three approaches to concurrent validity were taken including calculation of Pearson product moment correlation coefficients, repeated-measures ANOVAs, and Bland-Altman plots. Three-day test-retest reliability of BTrackS was examined in a second sample of 47 community-dwelling older adults (mean [SD] age = 75.8 [7.7] years) using intraclass correlation coefficients and MDC values at 95% CI (MDC95) were calculated. BTrackS demonstrated good validity using Pearson product moment correlations (r > 0.90). Repeated-measures ANOVA and Bland-Altman plots indicated some BTrackS bias with center of pressure (COP) values higher than FP COP values in the EO (mean [SD] bias = 4.0 [6.8]) and EC (mean [SD] bias = 9.6 [12.3]) conditions. Test-retest reliability using intraclass correlation coefficients (ICC2.1 was excellent (0.83) and calculated MDC95 for EO (9.6 cm) and EC (19.4 cm) and suggested that postural sway changes of these amounts are meaningful. BTrackS showed some bias with values exceeding force plate values in both EO and EC conditions. Excellent test-retest reliability and resulting MDC95 values indicated that BTrackS has the potential to identify meaningful changes in balance that may warrant intervention. BTrackS is an objective measure of balance that can be used to monitor balance in community-dwelling older adults over time. It can reliably identify changes that may require further attention (eg, fall-prevention strategies, declines in physical function) and shows promise for assessing intervention efficacy in this growing segment of the population.
Hong, Tae Ho; Choi, Joon-Il; Park, Michael Yong; Rha, Sung Eun; Lee, Young Joon; You, Young Kyoung; Choi, Moon Hyung
2017-01-01
AIM To evaluate the correlation between subjective assessments of pancreatic hardness based on the palpation, objective measurements using a durometer, and magnetic resonance imaging (MRI) findings for assessing pancreatic hardness. METHODS Eighty-three patients undergoing pancreatectomies were enrolled. An experienced surgeon subjectively evaluated the pancreatic hardness in the surgical field by palpation. The pancreatic hardness was also objectively evaluated using a durometer. Preoperative MRI findings were evaluated by a radiologist in terms of the apparent diffusion coefficient (ADC) values, the relative signal intensity decrease (RSID) of the pancreatic parenchyma, and the diameter of the pancreatic parenchyma and duct. Durometer measurement results, ADC values, RSID, pancreatic duct and parenchyma diameters, and the ratio of the diameters of the duct and parenchyma were compared between pancreases judged to be soft or hard pancreas on the palpation. A correlation analysis was also performed between the durometer and MRI measurements. RESULTS The palpation assessment classified 44 patients as having a soft pancreas and 39 patients as having a hard pancreas. ADC values were significantly lower in the hard pancreas group. The ductal diameter and duct-to-pancreas ratio were significantly higher in the hard pancreas group. For durometer measurements, a correlation analysis showed a positive correlation with the ductal diameter and the duct-to-pancreas ratio and a negative correlation with ADC values. CONCLUSION Hard pancreases showed lower ADC values, a wider pancreatic duct diameter and a higher duct-to-pancreas ratio than soft pancreases. Additionally, the ADC values, diameter of the pancreatic duct and duct-to-pancreas ratio were closely correlated with the durometer results. PMID:28373771
Shen, Ming; Zhang, Qilin; Liu, Wenjuan; Wang, Meng; Zhu, Jingjing; Ma, Zengyi; He, Wenqiang; Li, Shiqi; Shou, Xuefei; Li, Yiming; Zhang, Zhaoyun; Ye, Hongying; He, Min; Lu, Bin; Yao, Zhenwei; Lu, Yun; Qiao, Nidan; Ye, Zhao; Zhang, Yichao; Yang, Yeping; Zhao, Yao; Wang, Yongfei
2016-11-01
The difficulty of predicting the efficacy of somatostatin analogs (SSA) is not fully resolved. Here, we quantitatively evaluated the predictive value of relative signal intensity (rSI) on T1- and T2-weighted magnetic resonance imaging (MRI) for the short-term efficacy (3 months) of SSA therapy in patients with active acromegaly and assessed the correlation between MRI rSI and expression of somatostatin receptors (SSTR). This was a retrospective review of prospectively recorded data. Ninety-two newly diagnosed patients (37 males and 55 females) with active acromegaly were recruited. All patients were treated with pre-surgical SSA, followed by reassessment and transspenoidal surgery. rSI values were generated by calculating the ratio of SI in the tumor to the SI of normal frontal white matter. The Youden indices were calculated to determine the optimal cutoff of rSI to determine the efficacy of SSA. The correlation between rSI and expression of SSTR2/5 was analyzed by the Spearman rank correlation coefficient. T2 rSI was strongly correlated with biochemical sensitivity to SSA. The cutoff value of T2 rSI to distinguish biochemical sensitivity was 1.205, with a positive predictive value (PPV) of 81.5 % and a negative predictive value (NPV) of 77.3 %. No correlation was found between MRI and tumor size sensitivity. Moreover, T2 rSI was negatively correlated with the expression of SSTR5. T2 rSI correlates with the expression of SSTR5 and quantitatively predicts the biochemical efficacy of SSA in acromegaly.
Hong, Tae Ho; Choi, Joon-Il; Park, Michael Yong; Rha, Sung Eun; Lee, Young Joon; You, Young Kyoung; Choi, Moon Hyung
2017-03-21
To evaluate the correlation between subjective assessments of pancreatic hardness based on the palpation, objective measurements using a durometer, and magnetic resonance imaging (MRI) findings for assessing pancreatic hardness. Eighty-three patients undergoing pancreatectomies were enrolled. An experienced surgeon subjectively evaluated the pancreatic hardness in the surgical field by palpation. The pancreatic hardness was also objectively evaluated using a durometer. Preoperative MRI findings were evaluated by a radiologist in terms of the apparent diffusion coefficient (ADC) values, the relative signal intensity decrease (RSID) of the pancreatic parenchyma, and the diameter of the pancreatic parenchyma and duct. Durometer measurement results, ADC values, RSID, pancreatic duct and parenchyma diameters, and the ratio of the diameters of the duct and parenchyma were compared between pancreases judged to be soft or hard pancreas on the palpation. A correlation analysis was also performed between the durometer and MRI measurements. The palpation assessment classified 44 patients as having a soft pancreas and 39 patients as having a hard pancreas. ADC values were significantly lower in the hard pancreas group. The ductal diameter and duct-to-pancreas ratio were significantly higher in the hard pancreas group. For durometer measurements, a correlation analysis showed a positive correlation with the ductal diameter and the duct-to-pancreas ratio and a negative correlation with ADC values. Hard pancreases showed lower ADC values, a wider pancreatic duct diameter and a higher duct-to-pancreas ratio than soft pancreases. Additionally, the ADC values, diameter of the pancreatic duct and duct-to-pancreas ratio were closely correlated with the durometer results.
Correlation of heat transfer coefficient in quenching process using ABAQUS
NASA Astrophysics Data System (ADS)
Davare, Sandeep Kedarnath; Balachandran, G.; Singh, R. K. P.
2018-04-01
During the heat treatment by quenching in a liquid medium the convective heat transfer coefficient plays a crucial role in the extraction of heat. The heat extraction ultimately influences the cooling rate and hence the hardness and mechanical properties. A Finite Element analysis of quenching a simple flat copper sample with different orientation of sample and with different quenchant temperatures were carried out to check and verify the results obtained from the experiments. The heat transfer coefficient (HTC) was calculated from temperature history in a simple flat copper disc sample experimentally. This HTC data was further used as input to simulation software and the cooling curves were back calculated. The results obtained from software and using experimentation shows nearly consistent values.
Chin, Weng Yee; Choi, Edmond P H; Chan, Kit T Y; Wong, Carlos K H
2015-01-01
The Center for Epidemiologic Studies Depression Scale (CES-D) is a commonly used instrument to measure depressive symptomatology. Despite this, the evidence for its psychometric properties remains poorly established in Chinese populations. The aim of this study was to validate the use of the CES-D in Chinese primary care patients by examining factor structure, construct validity, reliability, sensitivity and responsiveness. The psychometric properties were assessed amongst a sample of 3686 Chinese adult primary care patients in Hong Kong. Three competing factor structure models were examined using confirmatory factor analysis. The original CES-D four-structure model had adequate fit, however the data was better fit into a bi-factor model. For the internal construct validity, corrected item-total correlations were 0.4 for most items. The convergent validity was assessed by examining the correlations between the CES-D, the Patient Health Questionnaire 9 (PHQ-9) and the Short Form-12 Health Survey (version 2) Mental Component Summary (SF-12 v2 MCS). The CES-D had a strong correlation with the PHQ-9 (coefficient: 0.78) and SF-12 v2 MCS (coefficient: -0.75). Internal consistency was assessed by McDonald's omega hierarchical (ωH). The ωH value for the general depression factor was 0.855. The ωH values for "somatic", "depressed affect", "positive affect" and "interpersonal problems" were 0.434, 0.038, 0.738 and 0.730, respectively. For the two-week test-retest reliability, the intraclass correlation coefficient was 0.91. The CES-D was sensitive in detecting differences between known groups, with the AUC >0.7. Internal responsiveness of the CES-D to detect positive and negative changes was satisfactory (with p value <0.01 and all effect size statistics >0.2). The CES-D was externally responsive, with the AUC>0.7. The CES-D appears to be a valid, reliable, sensitive and responsive instrument for screening and monitoring depressive symptoms in adult Chinese primary care patients. In its original four-factor and bi-factor structure, the CES-D is supported for cross-cultural comparisons of depression in multi-center studies.
Ibrahim, Edward F; Petrou, Charalambos; Galanos, Antonis
2015-01-01
Background The purpose of the present study was to validate the Functional Shoulder Score (FSS), a new patient-reported outcome score specifically designed to evaluate patients with rotator cuff disorders. Methods One hundred and nineteen patients were assessed using two shoulder scoring systems [the FSS and the Constant–Murley Score (CMS)] at 3 weeks pre- and 6 months post-arthroscopic rotator cuff surgery. The reliability, validity, responsiveness and interpretability of the FSS were evaluated. Results Reliability analysis (test–retest) showed an intraclass correlation coefficient value of 0.96 [95% confidence interval (CI) = 0.92 to 0.98]. Internal consistency analysis revealed a Cronbach's alpha coefficient of 0.93. The Pearson correlation coefficient FSS-CMS was 0.782 pre-operatively and 0.737 postoperatively (p < 0.0005). There was a statistically significant increase in FSS scores postoperatively, an effect size of 3.06 and standardized response mean of 2.80. The value for minimal detectable change was ±8.38 scale points (based on a 90% CI) and the minimal clinically important difference for improvement was 24.7 ± 5.4 points. Conclusions The FSS is a patient-reported outcome measure that can easily be incorporated into clinical practice, providing a quick, reliable, valid and practical measure for rotator cuff problems. The questionnaire is highly sensitive to clinical change. PMID:27582986
Sun, Lili; Zhou, Liping; Yu, Yu; Lan, Yukun; Li, Zhiliang
2007-01-01
Polychlorinated diphenyl ethers (PCDEs) have received more and more concerns as a group of ubiquitous potential persistent organic pollutants (POPs). By using molecular electronegativity distance vector (MEDV-4), multiple linear regression (MLR) models are developed for sub-cooled liquid vapor pressures (P(L)), n-octanol/water partition coefficients (K(OW)) and sub-cooled liquid water solubilities (S(W,L)) of 209 PCDEs and diphenyl ether. The correlation coefficients (R) and the leave-one-out cross-validation (LOO) correlation coefficients (R(CV)) of all the 6-descriptor models for logP(L), logK(OW) and logS(W,L) are more than 0.98. By using stepwise multiple regression (SMR), the descriptors are selected and the resulting models are 5-descriptor model for logP(L), 4-descriptor model for logK(OW), and 6-descriptor model for logS(W,L), respectively. All these models exhibit excellent estimate capabilities for internal sample set and good predictive capabilities for external samples set. The consistency between observed and estimated/predicted values for logP(L) is the best (R=0.996, R(CV)=0.996), followed by logK(OW) (R=0.992, R(CV)=0.992) and logS(W,L) (R=0.983, R(CV)=0.980). By using MEDV-4 descriptors, the QSPR models can be used for prediction and the model predictions can hence extend the current database of experimental values.
White, Sarah A; van den Broek, Nynke R
2004-05-30
Before introducing a new measurement tool it is necessary to evaluate its performance. Several statistical methods have been developed, or used, to evaluate the reliability and validity of a new assessment method in such circumstances. In this paper we review some commonly used methods. Data from a study that was conducted to evaluate the usefulness of a specific measurement tool (the WHO Colour Scale) is then used to illustrate the application of these methods. The WHO Colour Scale was developed under the auspices of the WHO to provide a simple portable and reliable method of detecting anaemia. This Colour Scale is a discrete interval scale, whereas the actual haemoglobin values it is used to estimate are on a continuous interval scale and can be measured accurately using electrical laboratory equipment. The methods we consider are: linear regression, correlation coefficients, paired t-tests plotting differences against mean values and deriving limits of agreement; kappa and weighted kappa statistics, sensitivity and specificity, an intraclass correlation coefficient and the repeatability coefficient. We note that although the definition and properties of each of these methods is well established inappropriate methods continue to be used in medical literature for assessing reliability and validity, as evidenced in the context of the evaluation of the WHO Colour Scale. Copyright 2004 John Wiley & Sons, Ltd.
Relationship of crop radiance to alfalfa agronomic values
NASA Technical Reports Server (NTRS)
Tucker, C. J.; Elgin, J. H., Jr.; Mcmurtrey, J. E., III
1980-01-01
Red and photographic infrared spectral data of alfalfa were collected at the time of the third and fourth cuttings using a hand-held radiometer for the earlier alfalfa cutting. Significant linear and non-linear correlation coefficients were found between the spectral variables and plant height, biomass, forage water content, and estimated canopy cover. For the alfalfa of the later cutting, which had experienced a period of severe drought stress which limited growth, the spectral variables were found to be highly correlated with the estimated drought scores.
Near-Infrared Spectroscopy Assay of Key Quality-Indicative Ingredients of Tongkang Tablets.
Pan, Wenjie; Ma, Jinfang; Xiao, Xue; Huang, Zhengwei; Zhou, Huanbin; Ge, Fahuan; Pan, Xin
2017-04-01
The objective of this paper is to develop an easy and fast near-infrared spectroscopy (NIRS) assay for the four key quality-indicative active ingredients of Tongkang tablets by comparing the true content of the active ingredients measured by high performance liquid chromatography (HPLC) and the NIRS data. The HPLC values for the active ingredients content of Cimicifuga glycoside, calycosin glucoside, 5-O-methylvisamminol and hesperidin in Tongkang tablets were set as reference values. The NIRS raw spectra of Tongkang tablets were processed using first-order convolution method. The iterative optimization method was chosen to optimize the band for Cimicifuga glycoside and 5-O-methylvisamminol, and correlation coefficient method was used to determine the optimal band of calycosin glucoside and hesperidin. A near-infrared quantitative calibration model was established for each quality-indicative ingredient by partial least-squares method on the basis of the contents detected by HPLC and the obtained NIRS spectra. The correlation coefficient R 2 values of the four models of Cimicifuga glycoside, calycosin glucoside, 5-O-methylvisamminol and hesperidin were 0.9025, 0.8582, 0.9250, and 0.9325, respectively. It was demonstrated that the accuracy of the validation values was approximately 90% by comparison of the predicted results from NIRS models and the HPLC true values, which suggested that NIRS assay was successfully established and validated. It was expected that the quantitative analysis models of the four indicative ingredients could be used to rapidly perform quality control in industrial production of Tongkang tablets.
Estimates of bottom roughness length and bottom shear stress in South San Francisco Bay, California
Cheng, R.T.; Ling, C.-H.; Gartner, J.W.; Wang, P.-F.
1999-01-01
A field investigation of the hydrodynamics and the resuspension and transport of participate matter in a bottom boundary layer was carried out in South San Francisco Bay (South Bay), California, during March-April 1995. Using broadband acoustic Doppler current profilers, detailed measurements of turbulent mean velocity distribution within 1.5 m above bed have been obtained. A global method of data analysis was used for estimating bottom roughness length zo and bottom shear stress (or friction velocities u*). Field data have been examined by dividing the time series of velocity profiles into 24-hour periods and independently analyzing the velocity profile time series by flooding and ebbing periods. The global method of solution gives consistent properties of bottom roughness length zo and bottom shear stress values (or friction velocities u*) in South Bay. Estimated mean values of zo and u* for flooding and ebbing cycles are different. The differences in mean zo and u* are shown to be caused by tidal current flood-ebb inequality, rather than the flooding or ebbing of tidal currents. The bed shear stress correlates well with a reference velocity; the slope of the correlation defines a drag coefficient. Forty-three days of field data in South Bay show two regimes of zo (and drag coefficient) as a function of a reference velocity. When the mean velocity is >25-30 cm s-1, the ln zo (and thus the drag coefficient) is inversely proportional to the reference velocity. The cause for the reduction of roughness length is hypothesized as sediment erosion due to intensifying tidal currents thereby reducing bed roughness. When the mean velocity is <25-30 cm s-1, the correlation between zo and the reference velocity is less clear. A plausible explanation of scattered values of zo under this condition may be sediment deposition. Measured sediment data were inadequate to support this hypothesis, but the proposed hypothesis warrants further field investigation.
Meyer, Hans-Jonas; Emmer, Alexander; Kornhuber, Malte; Surov, Alexey
2018-05-01
MRI is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an emergent imaging modality sensitive to microstructural alterations in tissue. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules. Electromyography (EMG) is a clinically used diagnostic tool in myositis. The aim of this study was to elucidate possible associations between ADC values and EMG findings in myositis patients. Seven patients (eight investigated muscles) with myositis (mean age 51.43 ± 19 years) were included in this study. The diagnosis was confirmed by histopathology in every case. DWI was obtained with a 1.5-T scanner using two b-values 0 and 1000 s/mm². In all patients, a needle electromyography (EMG) was performed within 3 days to the MRI. The following EMG parameters were studied: motor unit action potential (MUAP) amplitudes and durations, as well as pathological spontaneous activity. Spearman's correlation coefficient was used to analyze associations between investigated parameters. The estimated mean ADC mean value was 1.51 ± 0.29 × 10 -3 mm²/s, mean ADC min was 1.28 ± 0.27 × 10 -3 mm²/s, and mean ADC max was 1.73 ± 0.28 × 10 -3 mm²/s. Correlation analysis identified significant associations between ADC mean and duration of the MUAP (p = .78 P = .0279) and between ADC min and duration of the MUAP (p = .85, P = .01). There were no significant differences according to pathological spontaneous activity. ADC mean and ADC min showed strong positive correlations with the duration of the MUAP in myositis patients. Both modalities might similarly reflect muscle fiber loss in myositis patients.
Clot, Eric; Mégret, Claire; Eisenstein, Odile; Perutz, Robin N
2009-06-10
DFT calculations are reported of the energetics of C-H oxidative addition of benzene and fluorinated benzenes, Ar(F)H (Ar(F) = C(6)F(n)H(5-n), n = 0-5) at ZrCp(2) (Cp = eta(5)-C(5)H(5)), TaCp(2)H, TaCp(2)Cl, WCp(2), ReCp(CO)(2), ReCp(CO)(PH(3)), ReCp(PH(3))(2), RhCp(PH(3)), RhCp(CO), IrCp(PH(3)), IrCp(CO), Ni(H(2)PCH(2)CH(2)PH(2)), Pt(H(2)PCH(2)CH(2)PH(2)). The change in M-C bond energy of the products fits a linear function of the number of fluorine substituents, with different coefficients corresponding to ortho-, meta-, and para-fluorine. The values of the ortho-coefficient range from 20 to 32 kJ mol(-1), greatly exceeding the values for the meta- and para-coefficients (2.0-4.5 kJ mol(-1)). Similarly, the H-C bond energies of Ar(F)H yield ortho- and para-coefficients of 10.4 and 3.4 kJ mol(-1), respectively, and a negligible meta-coefficient. These results indicate a large increase in the M-C bond energy with ortho-fluorine substitution on the aryl ring. Plots of D(M-C) vs D(H-C) yield slopes R(M-C/H-C) that vary from 1.93 to 3.05 with metal fragment, all in excess of values of 1.1-1.3 reported with other hydrocarbyl groups. Replacement of PH(3) by CO decreases R(M-C/H-C) significantly. For a given ligand set and metals in the same group of the periodic table, the value of R(M-C/H-C) does not increase with the strength of the M-C bond. Calculations of the charge on the aryl ring show that variations in ionicity of the M-C bonds correlate with variations in M-C bond energy. This strengthening of metal-aryl bonds accounts for numerous experimental results that indicate a preference for ortho-fluorine substituents.
A Semi-Empirical Model for Forecasting Relativistic Electrons at Geostationary Orbit
NASA Technical Reports Server (NTRS)
Lyatsky, Wladislaw; Khazanov, George V.
2008-01-01
We developed a new prediction model for forecasting relativistic (>2MeV) electrons, which provides a VERY HIGH correlation between predicted and actually measured electron fluxes at geostationary orbit. This model implies the multi-step particle acceleration and is based on numerical integrating two linked continuity equations for primarily accelerated particles and relativistic electrons. The model includes a source and losses, and used solar wind data as only input parameters. We used the coupling function which is a best-fit combination of solar wind/Interplanetary Magnetic Field parameters, responsible for the generation of geomagnetic activity, as a source. The loss function was derived from experimental data. We tested the model for four year period 2004-2007. The correlation coefficient between predicted and actual values of the electron fluxes for whole four year period as well as for each of these years is about 0.9. The high and stable correlation between the computed and actual electron fluxes shows that the reliable forecasting these electrons at geostationary orbit is possible. The correlation coefficient between predicted and actual electron fluxes is stable and incredibly high.
NASA Astrophysics Data System (ADS)
Baranovskiy, Andrei; Amouyal, Yaron
2017-02-01
The electrical transport properties of CaO(CaMnO3)m (m = 1, 2, 3, ∞) compounds are studied applying the density functional theory (DFT) in terms of band structure at the vicinity of the Fermi level (EF). It is shown that the total density of states (DOS) values at EF increase with increase in the m-values, which implies an increase in the electrical conductivity, σ, with increasing m-values, in full accordance with experimental results. Additionally, the calculated values of the relative slopes of the DOS at EF correlate with the experimentally measured Seebeck coefficients. The electrical conductivity and Seebeck coefficients were calculated in the framework of the Boltzmann transport theory applying the constant relaxation time approximation. By the analysis of experimental and calculated σ(Τ) dependences, the electronic relaxation time and mean free path values were estimated. It is shown that the electrical transport is dominated by electron scattering on the boundaries between perovskite (CaMnO3) and Ca oxide (CaO) layers inside the crystal lattice.
Zhan, Yuefu; Liang, Xianwen; Han, Xiangjun; Chen, Jianqiang; Zhang, Shufang; Tan, Shun; Li, Qun; Wang, Xiong; Liu, Fan
2017-02-28
To explore the correlation between the apparent diffusion coefficient (ADC) and mRNA expression of tissue inhibitor of metalloproteinase-1 (TIMP-1) in different stages of liver fibrosis in rats. Methods: A model of liver fibrosis in rats was established by intraperitoneal injection of high-fat diet combined with porcine serum. After drug administration for 4 weeks, 48 rats served as a model group and 12 rats served as a control group, then they underwent diffusion weighted imaging (DWI) scanning. The value of ADC was calculated at b value=800 s/mm2. The rats were sacrificed and carried out pathologic examination after DWI scanning immediately. The mRNA expression of TIMP-1 was detected by real time-polymerase chain reaction (RT-PCR). The rats of hepatic fibrosis were also divided into a S0 group (n=4), a S1 group (n=11), a S2 group (n=12), a S3 group (n=10), and a S4 group (n=9) according to their pathological stage. The value of ADC and the expression of TIMP-1 mRNA among the different stage groups of liver fibrosis were compared, and the correlation between ADC and the TIMP-1 mRNA were analyzed. Results: The ADC value and the TIMP-1 mRNA expression were significantly different between the control group and the liver fibrosis group (F=46.54 and 53.87, P<0.05). There were significant differences in the value of ADC between every two groups (all P<0.05), except the control group vs the S1 group, the S1 group vs the S2 group, and the S2 group vs the S3 group (all P>0.05). For the comparison of TIMP-1 mRNA, there was no significant difference between the S1 group and the S2 group, the S3 group and the S4 group (both P>0.05). There were significant differences among the rest of the groups (all P<0.05). Rank correlation analysis showed that there was a negative correlation between the ADC value and the TIMP-1 mRNA expression (r=-0.76, P<0.01). Conclusion: When the value of ADC decreases in the progress of rats' liver fibrosis, the mRNA expression of TIMP-1 increases gradually, and there is a negative correlation between them.
Reliability of an interactive computer program for advance care planning.
Schubart, Jane R; Levi, Benjamin H; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J
2012-06-01
Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83-0.95, and 0.86-0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time.
NASA Astrophysics Data System (ADS)
Yazid, N. M.; Din, A. H. M.; Omar, K. M.; Som, Z. A. M.; Omar, A. H.; Yahaya, N. A. Z.; Tugi, A.
2016-09-01
Global geopotential models (GGMs) are vital in computing global geoid undulations heights. Based on the ellipsoidal height by Global Navigation Satellite System (GNSS) observations, the accurate orthometric height can be calculated by adding precise and accurate geoid undulations model information. However, GGMs also provide data from the satellite gravity missions such as GRACE, GOCE and CHAMP. Thus, this will assist to enhance the global geoid undulations data. A statistical assessment has been made between geoid undulations derived from 4 GGMs and the airborne gravity data provided by Department of Survey and Mapping Malaysia (DSMM). The goal of this study is the selection of the best possible GGM that best matches statistically with the geoid undulations of airborne gravity data under the Marine Geodetic Infrastructures in Malaysian Waters (MAGIC) Project over marine areas in Sabah. The correlation coefficients and the RMS value for the geoid undulations of GGM and airborne gravity data were computed. The correlation coefficients between EGM 2008 and airborne gravity data is 1 while RMS value is 0.1499.In this study, the RMS value of EGM 2008 is the lowest among the others. Regarding to the statistical analysis, it clearly represents that EGM 2008 is the best fit for marine geoid undulations throughout South China Sea.
Reliability of an Interactive Computer Program for Advance Care Planning
Levi, Benjamin H.; Camacho, Fabian; Whitehead, Megan; Farace, Elana; Green, Michael J
2012-01-01
Abstract Despite widespread efforts to promote advance directives (ADs), completion rates remain low. Making Your Wishes Known: Planning Your Medical Future (MYWK) is an interactive computer program that guides individuals through the process of advance care planning, explaining health conditions and interventions that commonly involve life or death decisions, helps them articulate their values/goals, and translates users' preferences into a detailed AD document. The purpose of this study was to demonstrate that (in the absence of major life changes) the AD generated by MYWK reliably reflects an individual's values/preferences. English speakers ≥30 years old completed MYWK twice, 4 to 6 weeks apart. Reliability indices were assessed for three AD components: General Wishes; Specific Wishes for treatment; and Quality-of-Life values (QoL). Twenty-four participants completed the study. Both the Specific Wishes and QoL scales had high internal consistency in both time periods (Knuder Richardson formula 20 [KR-20]=0.83–0.95, and 0.86–0.89). Test-retest reliability was perfect for General Wishes (κ=1), high for QoL (Pearson's correlation coefficient=0.83), but lower for Specific Wishes (Pearson's correlation coefficient=0.57). MYWK generates an AD where General Wishes and QoL (but not Specific Wishes) statements remain consistent over time. PMID:22512830
Genetic diversity of dog breeds: within-breed diversity comparing genealogical and molecular data.
Leroy, G; Verrier, E; Meriaux, J C; Rognon, X
2009-06-01
The genetic diversity of 61 dog breeds raised in France was investigated. Genealogical analyses were performed on the pedigree file of the French kennel club. A total of 1514 dogs were also genotyped using 21 microsatellite markers. For animals born from 2001 to 2005, the average coefficient of inbreeding ranged from 0.2% to 8.8% and the effective number of ancestors ranged from 9 to 209, according to the breed. The mean value of heterozygosity was 0.62 over all breeds (range 0.37-0.77). At the breed level, few correlations were found between genealogical and molecular parameters. Kinship coefficients and individual similarity estimators were, however, significantly correlated, with the best mean correlation being found for the Lynch & Ritland estimator (r = 0.43). According to both approaches, it was concluded that special efforts should be made to maintain diversity for three breeds, namely the Berger des Pyrénées, Braque Saint-Germain and Bull Terrier.
Magnetosphere-Ionosphere Coupling and Associated Ring Current Energization Processes
NASA Technical Reports Server (NTRS)
Liemohn, M. W.; Khazanov, G. V.
2004-01-01
Adiabatic processes in the ring current are examined. In particular, an analysis of the factors that parameterize the net adiabatic energy gain in the inner magnetosphere during magnetic storms is presented. A single storm was considered, that of April 17, 2002. Three simulations were conducted with similar boundary conditions but with different electric field descriptions. It is concluded that the best parameter for quantifying the net adiabatic energy gain in the inner magnetosphere during storms is the instantaneous value of the product of the maximum westward electric field at the outer simulation boundary with the nightside plasma sheet density. However, all of the instantaneous magnetospheric quantities considered in this study produced large correlation coefficients. Therefore, they all could be considered useful predictors of the net adiabatic energy gain of the ring current. Long integration times over the parameters lessen the significance of the correlation. Finally, some significant differences exist in the correlation coefficients depending on the electric field description.
Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.
Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M
2007-09-01
We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.
SCUD: fast structure clustering of decoys using reference state to remove overall rotation.
Li, Hongzhi; Zhou, Yaoqi
2005-08-01
We developed a method for fast decoy clustering by using reference root-mean-squared distance (rRMSD) rather than commonly used pairwise RMSD (pRMSD) values. For 41 proteins with 2000 decoys each, the computing efficiency increases nine times without a significant change in the accuracy of near-native selections. Tests on additional protein decoys based on different reference conformations confirmed this result. Further analysis indicates that the pRMSD and rRMSD values are highly correlated (with an average correlation coefficient of 0.82) and the clusters obtained from pRMSD and rRMSD values are highly similar (the representative structures of the top five largest clusters from the two methods are 74% identical). SCUD (Structure ClUstering of Decoys) with an automatic cutoff value is available at http://theory.med.buffalo.edu. (c) 2005 Wiley Periodicals, Inc.
Carreon, Leah Y; Bratcher, Kelly R; Das, Nandita; Nienhuis, Jacob B; Glassman, Steven D
2014-09-01
The Neck Disability Index (NDI) and numeric rating scales (0 to 10) for neck pain and arm pain are widely used cervical spine disease-specific measures. Recent studies have shown that there is a strong relationship between the SF-6D and the NDI such that using a simple linear regression allows for the estimation of an SF-6D value from the NDI alone. Due to ease of administration and scoring, the EQ-5D is increasingly being used as a measure of utility in the clinical setting. The purpose of this study is to determine if the EQ-5D values can be estimated from commonly available cervical spine disease-specific health-related quality of life measures, much like the SF-6D. The EQ-5D, NDI, neck pain score, and arm pain score were prospectively collected in 3732 patients who presented to the authors' clinic with degenerative cervical spine disorders. Correlation coefficients for paired observations from multiple time points between the NDI, neck pain and arm pain scores, and EQ-5D were determined. Regression models were built to estimate the EQ-5D values from the NDI, neck pain, and arm pain scores. The mean age of the 3732 patients was 53.3 ± 12.2 years, and 43% were male. Correlations between the EQ-5D and the NDI, neck pain score, and arm pain score were statistically significant (p < 0.0001), with correlation coefficients of -0.77, -0.62, and -0.50, respectively. The regression equation 0.98947 + (-0.00705 × NDI) + (-0.00875 × arm pain score) + (-0.00877 × neck pain score) to predict EQ-5D had an R-square of 0.62 and a root mean square error (RMSE) of 0.146. The model using NDI alone had an R-square of 0.59 and a RMSE of 0.150. The model using the individual NDI items had an R-square of 0.46 and an RMSE of 0.172. The correlation coefficient between the observed and estimated EQ-5D scores was 0.79. There was no statistically significant difference between the actual EQ-5D score (0.603 ± 0.235) and the estimated EQ-5D score (0.603 ± 0.185) using the NDI, neck pain score, and arm pain score regression model. However, rounding off the coefficients to fewer than 5 decimal places produced less accurate results. The regression model estimating the EQ-5D from the NDI, neck pain score, and arm pain score accounted for 60% of the variability of the EQ-5D with a relatively large RMSE. This regression model may not be sufficient to accurately or reliably estimate actual EQ-5D values.
Zheng, De-Xian; Meng, Shu-Chun; Liu, Qing-Jun; Li, Chuan-Ting; Shang, Xi-Dan; Zhu, Yu-Seng; Bai, Tian-Jun; Xu, Shi-Ming
2016-01-01
AIM: To determine if efficacy of chemotherapy on liver metastasis of gastrointestinal tract cancer can be predicted by apparent diffusion coefficient (ADC) values of diffusion-weighted imaging (DWI). METHODS: In total, 86 patients with liver metastasis of gastrointestinal tract cancer (156 metastatic lesions) diagnosed in our hospital were included in this study. The maximum diameters of these tumors were compared with each other before treatment, 2 wk after treatment, and 12 wk after treatment. Selected patients were classified as the effective group and the ineffective group, depending on the maximum diameter of the tumor after 12 wk of treatment; and the ADC values at different treatment times between the two groups were compared. Spearman rank correlation was used to analyze the relationship between ADC value and tumor diameter. Receiver operating characteristic curve (ROC curve) was used to analyze the ADC values before treatment to predict the patient’s sensitivity and specificity degree of efficacy to the chemotherapy. RESULTS: There was no difference in age between the two groups and in maximum tumor diameter before treatment and 2 wk after treatment. However, after 12 wk of treatment, maximum tumor diameter in the effective group was significantly lower than that in the ineffective group (P < 0.05). Before treatment, ADC values in the ineffective group were significantly higher than those in the effective group (P < 0.05). There was no difference in ADC values between the effective and ineffective groups after 2 and 12 wk of treatment. However, ADC values were significantly higher after 2 and 12 wk of treatment compared to before treatment in the effective group (P < 0.05). Spearman rank correlation analysis showed that ADC value before treatment and the reduced percentage of the maximum tumor diameter after 12 wk of treatment were negatively correlated, while the increase in the percentage of the ADC value 12 wk after treatment and the decrease in the percentage of the maximum tumor diameter were significantly positively correlated. The results of the ROC curve showed that ADC value with a chemotherapy ineffective threshold value of 1.14 × 10-3 mm2/s before treatment had a sensitivity and specificity of 94.3% and 76.7%, respectively. CONCLUSION: DWI ADC values can be used to predict the response of patients with liver metastasis of gastrointestinal tract cancer to chemotherapy with high sensitivity and relatively high specificity. PMID:26973399
Chen, Fei; Yang, Min; Li, Qian; Pan, Jay; Li, Xiaosong; Meng, Qun
2018-01-01
To understand whether the increased outpatient service provision (OSP) brings in enough additional income (excluding income from essential medicine) for primary hospitals (INCOME) to compensate for reduced costs of medicine. The two outcomes, annual OSP and INCOME for the period of 2008-2012, were collected from 34,506 primary hospitals in 2,675 counties in 31 provinces in China by the national surveillance system. The data had a four-level hierarchical structure; time points were nested within primary hospital, hospitals within county, and counties within province. We fitted bivariate five-level random effects regression models to examine correlations between OSP and INCOME in terms of their mean values and dose-response effects of the essential medicine policy (EMP). We adjusted for the effects of time period and selected hospital resources. The estimated correlation coefficients between the two outcomes' mean values were strongly positive among provinces (r = 0.910), moderately positive among counties (r = 0.380), and none among hospitals (r = 0.002) and time (r = 0.007). The correlation between their policy effects was weakly positive among provinces (r = 0.234), but none at the county and hospital levels. However, there were markedly negative correlation coefficients between the mean and policy effects at -0.328 for OSP and -0.541 for INCOME at the hospital level. There was no evidence to suggest an association between the two outcomes in terms of their mean values and dose-response effects of EMP at the hospital level. This indicated that increased OSP did not bring enough additional INCOME. Sustainable mechanisms to compensate primary hospitals are needed.
Reliability and Validity of a New Test of Agility and Skill for Female Amateur Soccer Players
Kutlu, Mehmet; Yapici, Hakan; Yilmaz, Abdullah
2017-01-01
Abstract The aim of this study was to evaluate the Agility and Skill Test, which had been recently developed to assess agility and skill in female athletes. Following a 10 min warm-up, two trials to test the reliability and validity of the test were conducted one week apart. Measurements were collected to compare soccer players’ physical performance in a 20 m sprint, a T-Drill test, the Illinois Agility Run Test, change-of-direction and acceleration, as well as agility and skill. All tests were completed following the same order. Thirty-four amateur female soccer players were recruited (age = 20.8 ± 1.9 years; body height = 166 ± 6.9 cm; body mass = 55.5 ± 5.8 kg). To determine the reliability and usefulness of these tests, paired sample t-tests, intra-class correlation coefficients, typical error, coefficient of variation, and differences between the typical error and smallest worthwhile change statistics were computed. Test results showed no significant differences between the two sessions (p > 0.01). There were higher intra-class correlations between the test and retest values (r = 0.94–0.99) for all tests. Typical error values were below the smallest worthwhile change, indicating ‘good’ usefulness for these tests. A near perfect Pearson correlation between the Agility and Skill Test (r = 0.98) was found, and there were moderate-to-large levels of correlation between the Agility and Skill Test and other measures (r = 0.37 to r = 0.56). The results of this study suggest that the Agility and Skill Test is a reliable and valid test for female soccer players and has significant value for assessing the integrative agility and skill capability of soccer players. PMID:28469760
Convergence at the faces of development workings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borisenko, A.A.
1977-07-01
Since 1963 we have been carrying out investigations in pits of the Pechora coalfield to establish the general laws of roof-floor convergence in the face areas of development workings and their role in gas bursts. We also considered how various methods of working on the seam influence the amount of type of convergence. The observations were made in 20 workings in five pits of Vorkutaugol Group, cut by cutter-loaders and by drilling and blasting at depths between 350 and 600 m; the cross-sectional areas of the workings ranged frm 3.7 to 12.0 m/sup 2/. The aggregated data on daily convergencemore » values was analyzed by the multiple correlation method with the aid of a computer. The aim of the analysis was to elucidate the influence of six factors on the daily convergence values: the depth below the surface, the corrected seam strength, the cross-sectional area of the working, the initial distance from the face to the measurement prop, the daily advance, and the thickness of the seam. The combined correlation coefficient was rather low - 0.49 with a reliability of 9.13. The greatest influence on the convergence values is exerted by the cross-sectional area and by the distance from the face (the partial correlation coefficients being 0.281 and 0.310, respectively), and lesser influences are exerted by the depth below the surface and by the corrected strength of the seam (partial correlationcoefficients 0.164 and 0.178); the influences of seam thickness and daily face advance are very slight. The multiple correlation results indicate that a very great influence is exerted by disregarded factors, among which the most important are undoubtedly the properties of the surrounding rocks.« less
Application of New Partition Coefficients to Modeling Plagioclase
NASA Technical Reports Server (NTRS)
Fagan, A. L.; Neal, C. R.; Rapp, J. F.; Draper, D. S.; Lapen, T. J.
2017-01-01
Previously, studies that determined the partition coefficient for an element, i, between plagioclase and the residual basaltic melt (Di plag) have been conducted using experimental conditions dissimilar from the Moon, and thus these values are not ideal for modeling plagioclase fractionation in a lunar system. However, recent work [1] has determined partition coefficients for plagioclase at lunar oxygen fugacities, and resulted in plagioclase with Anorthite contents =An90; these are significantly more calcic than plagioclase in previous studies, and the An content has a profound effect on partition coefficient values [2,3]. Plagioclase D-values, which are dependent on the An content of the crystal [e.g., 2-6], can be determined using published experimental data and the correlative An contents. Here, we examine new experimental data from [1] to ascertain their effect on the calculation of equilibrium liquids from Apollo 16 sample 60635,2. This sample is a coarse grained, subophitic impact melt composed of 55% plagioclase laths with An94.4-98.7 [7,8], distinctly more calcic than of previous partition coefficient studies (e.g., [3-6, 9-10]). Sample 60635,2 is notable as having several plagioclase trace element analyses containing a negative Europium anomaly (-Eu) in the rare-earth element (REE) profile, rather than the typical positive Eu anomaly (+Eu) [7-8] (Fig. 1). The expected +Eu is due to the similarity in size and charge with Ca2+, thereby allowing Eu2+ to be easily taken up by the plagioclase crystal structure, in contrast to the remaining REE3+. Some 60635,2 plagioclase crystals only have +Eu REE profiles, some only have -Eu REE profiles, and some +Eu and -Eu analyses in different areas on a single crystal [7, 8]. Moreover, there does not seem to be any core-rim association with the +Eu or -Eu analyses, nor does there appear to be a correlation between the size, shape, or location of a particular crystal within the sample and the sign of its Eu anomaly, which suggests a complex evolution. In order to investigate this sample further, we can calculate the equilibrium liquids, but with An contents distinct from previous experimental studies, we must calculate the appropriate partition coefficients for each trace element analysis.
Madhavan, Sangeetha; Campbell, Suzann K.; Campise-Luther, Rose; Gaebler-Spira, Deborah; Zawacki, Laura; Clark, April; Boynewicz, Kara; Kale, Dipti; Bulanda, Michelle; Yu, Jinsheng; Sui, Yi; Zhou, Xiaohong Joe
2014-01-01
Purpose To determine whether motor outcomes of an exercise intervention beginning at 2 months corrected age (CA) in children with periventricular brain injury (PBI) are correlated with fractional anisotropy (FA) measures derived from diffusion tensor imaging (DTI) at 12 months CA. Materials and Methods DTI was performed in eight infants with PBI who were randomly assigned to kicking and treadmill stepping exercise or a no-training condition. Development was assessed using the Alberta Infant Motor Scale (AIMS) and the Gross Motor Function Classification System (GMFCS). FA values were derived from regions of interest (ROI) in the middle third of the posterior limb of the internal capsule (PLIC) and the posterior thalamic radiation (PTR). Results Significant correlations were observed between motor development and FA measures. For PLIC, the correlation coefficients were 0.82 between FA and AIMS, and -0.92 between FA and GMFCS, while for PTR the corresponding correlation coefficients were 0.73 and -0.80, respectively. Conclusion Results of this study suggest that quantitative evaluation of white matter tracts using DTI at 12 months CA may be useful for assessment of brain plasticity in children. PMID:24136687
Madhavan, Sangeetha; Campbell, Suzann K; Campise-Luther, Rose; Gaebler-Spira, Deborah; Zawacki, Laura; Clark, April; Boynewicz, Kara; Kale, Dipti; Bulanda, Michelle; Yu, Jinsheng; Sui, Yi; Zhou, Xiaohong Joe
2014-04-01
To determine whether motor outcomes of an exercise intervention beginning at 2 months corrected age (CA) in children with periventricular brain injury (PBI) are correlated with fractional anisotropy (FA) measures derived from diffusion tensor imaging (DTI) at 12 months CA. DTI was performed in eight infants with PBI who were randomly assigned to kicking and treadmill stepping exercise or a no-training condition. Development was assessed using the Alberta Infant Motor Scale (AIMS) and the Gross Motor Function Classification System (GMFCS). FA values were derived from regions of interest (ROIs) in the middle third of the posterior limb of the internal capsule (PLIC) and the posterior thalamic radiation (PTR). Significant correlations were observed between motor development and FA measures. For PLIC, the correlation coefficients were 0.82 between FA and AIMS, and -0.92 between FA and GMFCS, while for PTR the corresponding correlation coefficients were 0.73 and -0.80, respectively. Results of this study suggest that quantitative evaluation of white matter tracts using DTI at 12 months CA may be useful for assessment of brain plasticity in children. Copyright © 2013 Wiley Periodicals, Inc.
Burström, Kristina; Johannesson, Magnus; Diderichsen, Finn
2006-05-01
This study aimed to compare directly elicited individual time trade-off (TTO) values in a general population sample with the social values derived using the UK EQ-5D index tariff. In the Stockholm County 1998 postal Public Health Survey (n=4950, 20-88 years), the EQ-5D self-classifier, a TTO and a rating scale (RS) question were included (n=2549 for all three questions). The mean TTO (EQ-5D) value was 0.943 (0.890) in the youngest age-group and 0.699 (0.733) in the oldest age-group. The difference between TTO and EQ-5D values was greater in more severe health status groups was. The same equation as for the UK EQ-5D index tariff was estimated for TTO and RS and resulted in significant and consistent coefficients for nearly all dimensions. The coefficients for moderate problems were closer to the EQ-5D index tariff than the coefficients for severe problems. Age was also significant after controlling for the EQ-5D dimensions (p<0.05). The results suggest that individual and social TTO values differ systematically and that the difference is greater the more severe the health status is. The social EQ-5D index tariff may also underestimate the severity in health status at older ages; age appears to correlate with additional health problems not captured by the EQ-5D classification.
A New Methodology of Spatial Cross-Correlation Analysis
Chen, Yanguang
2015-01-01
Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran’s index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson’s correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China’s urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes. PMID:25993120
A new methodology of spatial cross-correlation analysis.
Chen, Yanguang
2015-01-01
Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran's index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson's correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China's urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes.
Bogun, Frank; Taj, Majid; Ting, Michael; Kim, Hyungjin Myra; Reich, Stephen; Good, Eric; Jongnarangsin, Krit; Chugh, Aman; Pelosi, Frank; Oral, Hakan; Morady, Fred
2008-03-01
Pace mapping has been used to identify the site of origin of focal ventricular arrhythmias. The spatial resolution of pace mapping has not been adequately quantified using currently available three-dimensional mapping systems. The purpose of this study was to determine the spatial resolution of pace mapping in patients with idiopathic ventricular tachycardia or premature ventricular contractions originating in the right ventricular outflow tract. In 16 patients with idiopathic ventricular tachycardia/ectopy from the right ventricular outflow tract, comparisons and classifications of pace maps were performed by two observers (good pace map: match >10/12 leads; inadequate pace map: match < or =10/12 leads) and a customized MATLAB 6.0 program (assessing correlation coefficient and normalized root mean square of the difference (nRMSd) between test and template signals). With an electroanatomic mapping system, the correlation coefficient of each pace map was correlated with the distance between the pacing site and the effective ablation site. The endocardial area within the 10-ms activation isochrone was measured. The ablation procedure was effective in all patients. Sites with good pace maps had a higher correlation coefficient and lower nRMSd than sites with inadequate pace maps (correlation coefficient: 0.96 +/- 0.03 vs 0.76 +/- 0.18, P <.0001; nRMSd: 0.41 +/- 0.16 vs 0.89 +/- 0.39, P <.0001). Using receiver operating characteristic curves, appropriate cutoff values were >0.94 for correlation coefficient (sensitivity 81%, specificity 89%) and < or =0.54 for nRMSd (sensitivity 76%, specificity 80%). Good pace maps were located a mean of 7.3 +/- 5.0 mm from the effective ablation site and had a mean activation time of -24 +/- 7 ms. However, in 3 (18%) of 16 patients, the best pace map was inadequate at the effective ablation site, with an endocardial activation time at these sites of -25 +/- 12 ms. Pace maps with correlation coefficient > or =0.94 were confined to an area of 1.8 +/- 0.6 cm2. The 10-ms isochrone measured 1.2 +/- 0.7 cm2. The spatial resolution of a good pace map for targeting ventricular tachycardia/ectopy is 1.8 cm2 in the right ventricular outflow tract and therefore is inferior to the spatial resolution of activation mapping as assessed by isochronal activation. In approximately 20% of patients, pace mapping is unreliable in identifying the site of origin, possibly due a deeper site of origin and preferential conduction via fibers connecting the focus to the endocardial surface.
Kinchiku, Shigesumi; Kotani, Kazuhiko; Maruguchi, Yukiko; Aikou, Anna; Uenomachi, Hitoshi; Kajiya, Shouko
2016-12-01
Much attention has been paid recently to a relationship between glucose metabolism and weather. This study investigated the temporal correlation between total solar irradiance (TSI) and glycated hemoglobin (A1C) values in patients with diabetes. In 1531 patients with diabetes who received follow-up care between 2009 and 2013 (type 1 diabetes, 123 patients; type 2 diabetes, 1408 patients; male 53.6%; mean age, 61.2 years), A1C levels were measured a total of 58,830 times. The correlation between mean monthly TSI and mean A1C values from 1 to 4 months later was then examined. The mean values for TSI and A1C throughout the entire study period were 13.7 MJ/m 2 and 7.7%, respectively. The correlation coefficient between TSI and mean monthly A1C values at 1 to 4 months was -0.516, -0.734, -0.726 and -0.475, respectively (all p<0.001). There was a highly negative correlation between TSI and mean A1C values 2 to 3 months later in this population; thus, this fact may need to be considered when using A1C levels as a glycemic control index in patients with diabetes. Further studies are warranted. Copyright © 2016 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.
Spatial Variability and Distribution of the Metals in Surface Runoff in a Nonferrous Metal Mine
Ren, Bozhi; Chen, Yangbo; Zhu, Guocheng; Wang, Zhenghua; Zheng, Xie
2016-01-01
The spatial variation and distribution features of the metals tested in the surface runoff in Xikuangshan Bao Daxing miming area were analyzed by combining statistical methods with a geographic information system (GIS). The results showed that the maximum concentrations of those five kinds of the metals (Sb, Zn, Cu, Pb, and Cd) in the surface runoff of the antimony mining area were lower than the standard value except the concentration of metal Ni. Their concentrations were 497.1, 2.0, 1.8, 22.2, and 22.1 times larger than the standard value, respectively. This metal pollution was mainly concentrated in local areas, which were seriously polluted. The variation coefficient of Sb, Zn, Cu, Ni, Pb, and Cd was between 0.4 to 0.6, wherein the Sb's spatial variability coefficient is 50.56%, indicating a strong variability. Variation coefficients of the rest of metals were less than 50%, suggesting a moderate variability. The spatial structure analysis showed that the squared correlation coefficient (R 2) of the models fitting for Sb, Zn, Cu, Ni, Pb, and Cd was between 0.721 and 0.976; the ratio of the nugget value (C 0) to the abutment value (C + C 0) was between 0.0767 and 0.559; the semivariogram of Sb, Zn, Ni, and Pb was in agreement with a spherical model, while semivariogram of Cu and Cd was in agreement with Gaussian model, and both had a strong spatial correlation. The trend and spatial distribution indicated that those pollution distributions resulting from Ni, Pb, and Cd are similar, mainly concentrated in both ends of north and south in eastern part. The main reasons for the pollution were attributed to the residents living, transportation, and industrial activities; the Sb distribution was concentrated mainly in the central part, of which the pollution was assigned to the mining and the industrial activity; the pollution distributions of Zn and Cu were similar, mainly concentrated in both ends of north and south as well as in west; the sources of the metals were widely distributed. PMID:27069713
Lab and Pore-Scale Study of Low Permeable Soils Diffusional Tortuosity
NASA Astrophysics Data System (ADS)
Lekhov, V.; Pozdniakov, S. P.; Denisova, L.
2016-12-01
Diffusion plays important role in contaminant spreading in low permeable units. The effective diffusion coefficient of saturated porous medium depends on this coefficient in water, porosity and structural parameter of porous space - tortuosity. Theoretical models of relationship between porosity and diffusional tortuosity are usually derived for conceptual granular models of medium filled by solid particles of simple geometry. These models usually do not represent soils with complex microstructure. The empirical models, like as Archie's law, based on the experimental electrical conductivity data are mostly useful for practical applications. Such models contain empirical parameters that should be defined experimentally for given soil type. In this work, we compared tortuosity values obtained in lab-scale diffusional experiments and pore scale diffusion simulation for the studied soil microstructure and exanimated relationship between tortuosity and porosity. Samples for the study were taken from borehole cores of low-permeable silt-clay formation. Using the samples of 50 cm3 we performed lab scale diffusional experiments and estimated the lab-scale tortuosity. Next using these samples we studied the microstructure with X-ray microtomograph. Shooting performed on undisturbed microsamples of size 1,53 mm with a resolution ×300 (10243 vox). After binarization of each obtained 3-D structure, its spatial correlation analysis was performed. This analysis showed that the spatial correlation scale of the indicator variogram is considerably smaller than microsample length. Then there was the numerical simulation of the Laplace equation with binary coefficients for each microsamples. The total number of simulations at the finite-difference grid of 1753 cells was 3500. As a result the effective diffusion coefficient, tortuosity and porosity values were obtained for all studied microsamples. The results were analyzed in the form of graph of tortuosity versus porosity. The 6 experimental tortuosity values well agree with pore-scale simulations falling in the general pattern that shows nonlinear decreasing of tortuosity with decreasing of porosity. Fitting this graph by Archie model we found exponent value in the range between 1,8 and 2,4. This work was supported by RFBR via grant 14-05-00409.
NASA Astrophysics Data System (ADS)
Wang, Gang-Jin; Xie, Chi; Chen, Shou; Yang, Jiao-Jiao; Yang, Ming-Yan
2013-09-01
In this study, we first build two empirical cross-correlation matrices in the US stock market by two different methods, namely the Pearson’s correlation coefficient and the detrended cross-correlation coefficient (DCCA coefficient). Then, combining the two matrices with the method of random matrix theory (RMT), we mainly investigate the statistical properties of cross-correlations in the US stock market. We choose the daily closing prices of 462 constituent stocks of S&P 500 index as the research objects and select the sample data from January 3, 2005 to August 31, 2012. In the empirical analysis, we examine the statistical properties of cross-correlation coefficients, the distribution of eigenvalues, the distribution of eigenvector components, and the inverse participation ratio. From the two methods, we find some new results of the cross-correlations in the US stock market in our study, which are different from the conclusions reached by previous studies. The empirical cross-correlation matrices constructed by the DCCA coefficient show several interesting properties at different time scales in the US stock market, which are useful to the risk management and optimal portfolio selection, especially to the diversity of the asset portfolio. It will be an interesting and meaningful work to find the theoretical eigenvalue distribution of a completely random matrix R for the DCCA coefficient because it does not obey the Marčenko-Pastur distribution.
Alonso de Mezquia, David; Wang, Zilin; Lapeira, Estela; Klein, Michael; Wiegand, Simone; Mounir Bou-Ali, M
2014-11-01
In this study, the thermodiffusion, molecular diffusion, and Soret coefficients of 12 binary mixtures composed of toluene, n-hexane and n-dodecane in the whole range of concentrations at atmospheric pressure and temperatures of 298.15 K and 308.15 K have been determined. The experimental measurements have been carried out using the Thermogravitational Column, the Sliding Symmetric Tubes and the Thermal Diffusion Forced Rayleigh Scattering techniques. The results obtained using the different techniques show a maximum deviation of 9% for the thermodiffusion coefficient, 8% for the molecular diffusion coefficient and 2% for the Soret coefficient. For the first time we report a decrease of the thermodiffusion coefficient with increasing ratio of the thermal expansion coefficient and viscosity for a binary mixture of an organic ring compound with a short n-alkane. This observation is discussed in terms of interactions between the different components. Additionally, the thermogravitational technique has been used to measure the thermodiffusion coefficients of four ternary mixtures consisting of toluene, n-hexane and n-dodecane at 298.15 K. In order to complete the study, the values obtained for the molecular diffusion coefficient in binary mixtures, and the thermodiffusion coefficient of binary and ternary mixtures have been compared with recently derived correlations.
Ahmadi, Seyed Mehdi; Keshavarzi, Sareh; Mostafavi, Seyed-Ali; Bagheri Lankarani, Kamran
2015-11-01
Overweight/obesity and depression are common among women especially in the elderly and can lead to unfavorable outcomes. We aimed to determine the association of overweight with depression and also to find any correlation of depression with some anthropometric indices in old women. A total of 94 depressed elderly women were compared with 99 non-depressed controls. The structured diagnostic interview based on DSM-IV were performed to diagnose depression, and Geriatric Depression Scale (GDS) was completed to rate it. Anthropometric indices were measured and compared between groups. Pearson correlation coefficients were determined for linear relations between variables. Odds Ratio of obesity and overweight in depressed subjects comparing with normal participants was 1.45 (95%CI=0.63-3.32). A significant correlation was observed between BMI and GDS score (r=0.231, P-value=0.001). Total body fat (P-value=0.001) and BMI (P-value=0.016) were significantly higher in depressed women than non-depressed women. Despite the significantly higher total body fat and BMI among old women with depression, only a weak correlation was seen between BMI and GDS score.
Comparison of the color of natural teeth measured by a colorimeter and Shade Vision System.
Cho, Byeong-Hoon; Lim, Yong-Kyu; Lee, Yong-Keun
2007-10-01
The objectives were to measure the difference in the color and color parameters of natural teeth measured by a tristimulus colorimeter (CM, used as a reference) and Shade Vision System (SV), and to determine the influence of color parameters on the color difference between the values measured by two instruments. Color of 12 maxillary and mandibular anterior teeth was measured by CM and SV for 47 volunteers (number of teeth=564). Color parameters such as CIE L*, a* and b* values, chroma and hue angle measured by two instruments were compared. Chroma was calculated as C*ab=(a*2 = b*2)1/2, and hue angle was calculated as h degrees =arctan(b*/a*). The influence of color parameters measured by CM on the color difference (DeltaE*(ab)) between the values measured by two instruments was analyzed with multiple regression analysis (alpha=0.01). Mean DeltaE*(ab) value between the values measured by two instruments was 21.7 (+/-3.7), and the mean difference in lightness (CIE L*) and chroma was 16.2 (+/-3.9) and 13.2 (+/-3.0), respectively. Difference in hue angle was high as 132.7 (+/-53.3) degrees . Except for the hue angle, all the color parameters showed significant correlations and the coefficient of determination (r(2)) was in the range of 0.089-0.478. Based on multiple regression analysis, the standardized partial correlation coefficient (beta) of the included predictors for the color difference was -0.710 for CIE L* and -0.300 for C*(ab) (p<0.01). All the color parameters showed significant but weak correlations except for hue angle. When lightness and chroma of teeth were high, color difference between the values measured by two instruments was small. Clinical accuracy of two instruments should be investigated further.
Meyer, Hans-Jonas; Ziemann, Oliver; Kornhuber, Malte; Emmer, Alexander; Quäschling, Ulf; Schob, Stefan; Surov, Alexey
2018-06-01
Background Magnetic resonance imaging (MRI) is widely used in several muscle disorders. Diffusion-weighted imaging (DWI) is an imaging modality, which can reflect microstructural tissue composition. The apparent diffusion coefficient (ADC) is used to quantify the random motion of water molecules in tissue. Purpose To investigate ADC values in patients with myositis and non-inflammatory myopathy and to analyze possible associations between ADC and laboratory parameters in these patients. Material and Methods Overall, 17 patients with several myositis entities, eight patients with non-inflammatory myopathies, and nine patients without muscle disorder as a control group were included in the study (mean age = 55.3 ± 14.3 years). The diagnosis was confirmed by histopathology in every case. DWI was obtained in a 1.5-T scanner using two b-values: 0 and 1000 s/mm 2 . In all patients, the blood sample was acquired within three days to the MRI. The following serological parameters were estimated: C-reactive protein, lactate dehydrogenase, alanine aminotransferase, aspartate aminotransferase, creatine kinase, and myoglobine. Results The estimated mean ADC value for the myositis group was 1.89 ± 0.37 × 10 -3 mm 2 /s and for the non-inflammatory myopathy group was 1.79 ± 0.33 × 10 -3 mm 2 /s, respectively. The mean ADC values (1.15 ± 0.37 × 10 -3 mm 2 /s) were significantly higher to unaffected muscles (vs. myositis P = 0.0002 and vs. myopathy P = 0.0021). There were no significant correlations between serological parameters and ADC values. Conclusion Affected muscles showed statistically significantly higher ADC values than normal muscles. No linear correlations between ADC and serological parameters were identified.
Miyata, Hiroshi; Miyata, Satoru
2018-01-01
To speculate on the time-dependent change of FIB4 index in patients with nonalcoholic fatty liver disease (NAFLD) and its increase-decrease rate per year, simply and accurately. In all 23 patients with NAFLD with the value of FIB4 index over 1.30 at the peak, the period from the first to each examination date was calculated and this period (years) was regarded as x . Next, the mean value of FIB4 index during the past year to each examination date was regarded as y . In every y , the minimum and the maximum y value were found out. Between x corresponding to this minimum y and x corresponding to this maximum y , the correlation between x and y was analyzed as the main subject. Then, the slope of each correlation was investigated, because it should indicate increase-decrease rate per year. In all 23 patients, the correlations as the main subject were recognized and the mean absolute value of correlation coefficient ( r ) was 0.91 ± 0.08. As for the slope, the mean absolute value was 0.1371 ± 0.1147 (/year). Simply and accurately, the time-dependent change of FIB4 index and its increase-decrease rate per year could be approximately speculated.
Medina-Rosas, Jorge; Gladman, Dafna D; Su, Jiandong; Sabapathy, Arthy; Urowitz, Murray B; Touma, Zahi
2015-10-24
In this study, we determined: (1) the utility of an untimed sample of urine protein/creatinine ratio (PCR) as a screening test for proteinuria, (2) its ability to accurately measure proteinuria, and (3) cutoff values for PCR predicting protein content in a 24-h urine collection sample (24hP) of 0.5, 1.0, and 2.0 g/day. Analysis was performed on data from a single lupus cohort (2008-2014). Proteinuria was measured in a 24hP and with PCR. On the basis of 24hP, samples were divided into 4 groups: group 1, <0.5 g/day; group 2, 0.5-0.99 g/day; group 3, 1-1.99 g/day; and group 4, ≥2 g/day. To determine the validity of PCR in screening for proteinuria, the Pearson correlation coefficient was determined for the urine samples with normal PCR (<0.05 g/mmol) and normal 24hP (<0.5 g/day). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PCR were calculated. To determine the ability of PCR to accurately measure the level of proteinuria, in addition to the correlation between 24hP and PCR, agreement was determined by intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plot between 24hP/24hC and PCR. The best cutoffs for PCR predicting a 24hP of 0.5, 1.0, and 2.0 g/day were determined with the receiver operating characteristic curve. The correlation of the samples with normal PCR as well as 24hP (n = 552) was 0.29 (p < 0.0001). PCR sensitivity and specificity against 24hP were 91 % and 83 %, respectively. The PPV was 82.5 %, and the NPV was 91.4 %. The correlation for all samples (n = 1233) was high, but low to moderate for groups 1, 2, 3, and 4. The agreement for all samples was appropriate but poor for groups 1, 2, 3, and 4. PCR cutoffs for 24hP of 0.5, 1.0, and 2.0 g/day were 0.08, 0.16, and 0.35 g/mmol, respectively. PCR can be used as a screening test for proteinuria, and the best cutoff value to predict a 24hP of 0.5 g/day is 0.08 g/mmol (800 mg/g). The accurate level of proteinuria should be measured by the gold standard test, 24hP.
Diagnostic value of the plasmatic ADM level for early ectopic pregnancy.
Yan, Qi; Lu, Qi; Tao, Yu; Wang, Yu-Dong; Zhao, Wen-Xia
2015-01-01
To analyze the plasmatic ADM level in early pregnancy and to investigate the diagnostic value of ADM in early ectopic pregnancy (EP). 70 patients with EP who had menopause for 5~8 weeks were included as study group, while 155 women with normal intrauterine pregnancy were also included as control group. The correlation between ADM level and menopause weeks was statistically analyzed and ROC curve was used to identify the diagnostic value of ADM. (1) In 155 cases of normal intrauterine pregnancy, the plasmatic ADM level was increased with menopause weeks in linear relationship, and the correlation coefficient (R) was 0.991 (P<0.05). In 70 patients with EP, no significant increase was found with menopause weeks and no linear relationship can be found between ADM level and menopause weeks in EP group. The correlation coefficient (R) was 0.744 (P>0.05). (2) The multiple of median of plasmatic ADM level in EP group of menopause for 8 weeks was obviously lower than the intrauterine control group (P<0.01). (3) ROC curve was used to analyze the cut-off value of ADM level in the diagnosis of EP, and the area under the ROC curve was 0.523 (P>0.05) regardless of menopause weeks, however, the area under the ROC curve was 0.702 (P<0.05) at 8 weeks after menopause with sensitivity of 53.50% and specificity of 85.00%. Different from normal intrauterine pregnancy, plasmatic ADM level in early EP was relatively lower and no significant increase was found with menopause weeks; further studies are still needed for plasmatic ADM level as an indicator in the early diagnosis of EP.
Prospective comparison of speckle tracking longitudinal bidimensional strain between two vendors.
Castel, Anne-Laure; Szymanski, Catherine; Delelis, François; Levy, Franck; Menet, Aymeric; Mailliet, Amandine; Marotte, Nathalie; Graux, Pierre; Tribouilloy, Christophe; Maréchaux, Sylvestre
2014-02-01
Speckle tracking is a relatively new, largely angle-independent technique used for the evaluation of myocardial longitudinal strain (LS). However, significant differences have been reported between LS values obtained by speckle tracking with the first generation of software products. To compare LS values obtained with the most recently released equipment from two manufacturers. Systematic scanning with head-to-head acquisition with no modification of the patient's position was performed in 64 patients with equipment from two different manufacturers, with subsequent off-line post-processing for speckle tracking LS assessment (Philips QLAB 9.0 and General Electric [GE] EchoPAC BT12). The interobserver variability of each software product was tested on a randomly selected set of 20 echocardiograms from the study population. GE and Philips interobserver coefficients of variation (CVs) for global LS (GLS) were 6.63% and 5.87%, respectively, indicating good reproducibility. Reproducibility was very variable for regional and segmental LS values, with CVs ranging from 7.58% to 49.21% with both software products. The concordance correlation coefficient (CCC) between GLS values was high at 0.95, indicating substantial agreement between the two methods. While good agreement was observed between midwall and apical regional strains with the two software products, basal regional strains were poorly correlated. The agreement between the two software products at a segmental level was very variable; the highest correlation was obtained for the apical cap (CCC 0.90) and the poorest for basal segments (CCC range 0.31-0.56). A high level of agreement and reproducibility for global but not for basal regional or segmental LS was found with two vendor-dependent software products. This finding may help to reinforce clinical acceptance of GLS in everyday clinical practice. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Rollmann, P.; Spindler, K.; Müller-Steinhagen, H.
2011-08-01
The heat transfer, pressure drop and flow patterns during flow boiling of R407C in a horizontal microfin tube have been investigated. The microfin tube is made of copper with a total fin number of 55 and a helix angle of 15°. The fin height is 0.24 mm and the inner tube diameter at fin root is 8.95 mm. The test tube is 1 m long. It is heated electrically. The experiments have been performed at saturation temperatures between -30°C and +10°C. The mass flux was varied between 25 and 300 kg/m2/s, the heat flux from 20,000 W/m2 down to 1,000 W/m2. The vapour quality was kept constant at 0.1, 0.3, 0.5, 0.7 at the inlet and 0.8, 1.0 at the outlet, respectively. The measured heat transfer coefficient is compared with the correlations of Cavallini et al., Shah as well as Zhang et al. Cavallini's correlation contains seven experimental constants. After fitting these constants to our measured values, the correlation achieves good agreement. The measured pressure drop is compared to the correlations of Pierre, Kuo and Wang as well as Müller-Steinhagen and Heck. The best agreement is achieved with the correlation of Kuo and Wang. Almost all values are calculated within an accuracy of ±30%. The flow regimes were observed. It is shown, that changes in the flow regime affect the heat transfer coefficient significantly.
Determining Baseline Stress-Related Hormone Values in Large Cetaceans
2014-09-30
reconstructed chemical profiles provided a unique window into stress-related hormone (cortisol, aldosterone , T3 and T4) concentrations and...Stress-related hormone radioimmunoassay technique Cortisol, aldosterone , hormones thyroxine (T4) and triiodothyronine (T3) levels in each identified...contaminant concentrations will be calculated using Pearson correlation coefficients. These measurements will include all hormones ( aldosterone , T3
İlçin, Nursen; Gürpınar, Barış; Bayraktar, Deniz; Savcı, Sema; Çetin, Pınar; Sarı, İsmail; Akkoç, Nurullah
2016-01-01
[Purpose] This study describes the cultural adaptation, validation, and reliability of the Turkish version of the Pain Catastrophizing Scale in patients with ankylosing spondylitis. [Methods] The validity of the Turkish version of the Pain Catastrophizing Scale was assessed by evaluating data quality (missing data and floor and ceiling effects), principal components analysis, internal consistency (Cronbach’s alpha), and construct validity (Spearman’s rho). Reproducibility analyses included standard measurement error, minimum detectable change, limits of agreement, and intraclass correlation coefficients. [Results] Sixty-four adult patients with ankylosing spondylitis with a mean age of 42.2 years completed the study. Factor analysis revealed that all questionnaire items could be grouped into two factors. Excellent internal consistency was found, with a Chronbach’s alpha value of 0.95. Reliability analyses showed an intraclass correlation coefficient (95% confidence interval) of 0.96 for the total score. There was a low correlation coefficient between the Turkish version of the Pain Catastrophizing Scale and body mass index, pain levels at rest and during activity, health-related quality of life, and fear and avoidance behaviors. [Conclusion] The results of this study indicate that the Turkish version of the Pain Catastrophizing Scale is a valid and reliable clinical and research tool for patients with ankylosing spondylitis. PMID:26957778
Zhang, Yong-Hong; Xia, Zhi-Ning; Qin, Li-Tang; Liu, Shu-Shen
2010-09-01
The objective of this paper is to build a reliable model based on the molecular electronegativity distance vector (MEDV) descriptors for predicting the blood-brain barrier (BBB) permeability and to reveal the effects of the molecular structural segments on the BBB permeability. Using 70 structurally diverse compounds, the partial least squares regression (PLSR) models between the BBB permeability and the MEDV descriptors were developed and validated by the variable selection and modeling based on prediction (VSMP) technique. The estimation ability, stability, and predictive power of a model are evaluated by the estimated correlation coefficient (r), leave-one-out (LOO) cross-validation correlation coefficient (q), and predictive correlation coefficient (R(p)). It has been found that PLSR model has good quality, r=0.9202, q=0.7956, and R(p)=0.6649 for M1 model based on the training set of 57 samples. To search the most important structural factors affecting the BBB permeability of compounds, we performed the values of the variable importance in projection (VIP) analysis for MEDV descriptors. It was found that some structural fragments in compounds, such as -CH(3), -CH(2)-, =CH-, =C, triple bond C-, -CH<, =C<, =N-, -NH-, =O, and -OH, are the most important factors affecting the BBB permeability. (c) 2010. Published by Elsevier Inc.
Calculating sediment discharge from a highway construction site in central Pennsylvania
Reed, L.A.; Ward, J.R.; Wetzel, K.L.
1985-01-01
The Pennsylvania Department of Transportation, the Federal Highway Administration, and the U.S. Geological Survey have cooperated in a study to evaluate two methods of predicting sediment yields during highway construction. Sediment yields were calculated using the Universal Soil Loss and the Younkin Sediment Prediction Equations. Results were compared to the actual measured values, and standard errors and coefficients of correlation were calculated. Sediment discharge from the construction area was determined for storms that occurred during construction of Interstate 81 in a 0.38-square mile basin near Harrisburg, Pennsylvania. Precipitation data tabulated included total rainfall, maximum 30-minute rainfall, kinetic energy, and the erosive index of the precipitation. Highway construction data tabulated included the area disturbed by clearing and grubbing, the area in cuts and fills, the average depths of cuts and fills, the area seeded and mulched, and the area paved. Using the Universal Soil Loss Equation, sediment discharge from the construction area was calculated for storms. The standard error of estimate was 0.40 (about 105 percent), and the coefficient of correlation was 0.79. Sediment discharge from the construction area was also calculated using the Younkin Equation. The standard error of estimate of 0.42 (about 110 percent), and the coefficient of correlation of 0.77 are comparable to those from the Universal Soil Loss Equation.
Testing a single regression coefficient in high dimensional linear models
Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling
2017-01-01
In linear regression models with high dimensional data, the classical z-test (or t-test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z-test to assess the significance of each covariate. Based on the p-value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively. PMID:28663668
Testing a single regression coefficient in high dimensional linear models.
Lan, Wei; Zhong, Ping-Shou; Li, Runze; Wang, Hansheng; Tsai, Chih-Ling
2016-11-01
In linear regression models with high dimensional data, the classical z -test (or t -test) for testing the significance of each single regression coefficient is no longer applicable. This is mainly because the number of covariates exceeds the sample size. In this paper, we propose a simple and novel alternative by introducing the Correlated Predictors Screening (CPS) method to control for predictors that are highly correlated with the target covariate. Accordingly, the classical ordinary least squares approach can be employed to estimate the regression coefficient associated with the target covariate. In addition, we demonstrate that the resulting estimator is consistent and asymptotically normal even if the random errors are heteroscedastic. This enables us to apply the z -test to assess the significance of each covariate. Based on the p -value obtained from testing the significance of each covariate, we further conduct multiple hypothesis testing by controlling the false discovery rate at the nominal level. Then, we show that the multiple hypothesis testing achieves consistent model selection. Simulation studies and empirical examples are presented to illustrate the finite sample performance and the usefulness of the proposed method, respectively.
Use of the mouse jumping test for estimating antagonistic potencies of morphine antagonists.
Cowan, A
1976-03-01
The potencies of 19 reference morphine antagonists have been compared in a modified version of the mouse jumping test. Mice were each implanted subcutaneously with one 75 mg pellet of morphine. Antagonist challenge took place 72 h later and the incidence of repetitive vertical-jumping was monitored over 1 h. A high Pearson correlation coefficient (r = 0.997) was found between quantitative assays based on the total number of jumps per mouse and quantal assays based on mice jumping at least 6 times. A comparison of relative potencies obtained with the mouse test and with non-withdrawn morphine-dependent monkeys gave a Spearman rank order coefficient of 0.91 while a similar comparison with values obtained with the guinea-pig isolated ileum preparation also gave a high correlation coefficient (r= 0.92). Whereas it is difficult to assess the antagonistic component of buprenorphine and cyclorphan with the ileum preparation, both compounds can be satisfactorily assayed in the mouse jumping test. The reported antagonistic properties of ketocyclazocine and profadol could not be confirmed in the mouse model.
Heat transfer and pressure drop in rectangular channels with crossing fins (a Review)
NASA Astrophysics Data System (ADS)
Sokolov, N. P.; Polishchuk, V. G.; Andreev, K. D.; Rassokhin, V. A.; Zabelin, N. A.
2015-06-01
Channels with crossing finning find wide use in the cooling paths of high-temperature gas turbine blade systems. At different times, different institutions carried out experimental investigations of heat transfer and pressure drop in channels with coplanar finning of opposite walls for obtaining semiempirical dependences of Nusselt criteria (dimensionless heat-transfer coefficients) and pressure drop coefficients on the operating Reynolds number and relative geometrical parameters (or their complexes). The shape of experimental channels, the conditions of experiments, and the used variables were selected so that they would be most suited for solving particular practical tasks. Therefore, the results obtained in processing the experimental data have large scatter and limited use. This article considers the results from experimental investigations of different authors. In comparing the results, additional calculations were carried out for bringing the mathematical correlations to the form of dependences from the same variables. Generalization of the results is carried out. In the final analysis, universal correlations are obtained for determining the pressure drop coefficients and Nusselt number values for the flow of working medium in channels with coplanar finning.
Microbial Transformation of Esters of Chlorinated Carboxylic Acids
Paris, D. F.; Wolfe, N. L.; Steen, W. C.
1984-01-01
Two groups of compounds were selected for microbial transformation studies. In the first group were carboxylic acid esters having a fixed aromatic moiety and an increasing length of the alkyl component. Ethyl esters of chlorine-substituted carboxylic acids were in the second group. Microorganisms from environmental waters and a pure culture of Pseudomonas putida U were used. The bacterial populations were monitored by plate counts, and disappearance of the parent compound was followed by gas-liquid chromatography as a function of time. The products of microbial hydrolysis were the respective carboxylic acids. Octanol-water partition coefficients (Kow) for the compounds were measured. These values spanned three orders of magnitude, whereas microbial transformation rate constants (kb) varied only 50-fold. The microbial rate constants of the carboxylic acid esters with a fixed aromatic moiety increased with an increasing length of alkyl substituents. The regression coefficient for the linear relationships between log kb and log Kow was high for group 1 compounds, indicating that these parameters correlated well. The regression coefficient for the linear relationships for group 2 compounds, however, was low, indicating that these parameters correlated poorly. PMID:16346459
Chesson, Harrell W; Owusu-Edusei, Kwame; Leichliter, Jami S; Aral, Sevgi O
2013-11-01
Numerous social determinants of health are associated with violent crime rates and sexually transmissible infection (STI) rates. This report aims to illustrate the potential usefulness of violent crime rates as a proxy for the social determinants of STI rates. For each year from 1981 to 2010, we assessed the strength of the association between the violent crime rate and the gonorrhoea (Neisseria gonorrhoeae) rate (number of total reported cases per 100?000) at the state level. Specifically, for each year, we calculated Pearson correlation coefficients (and P-values) between two variables (the violent crime rate and the natural log of the gonorrhoea rate) for all 50 states and Washington, DC. For comparison, we also examined the correlation between gonorrhoea rates, and rates of poverty and unemployment. We repeated the analysis using overall syphilis rates instead of overall gonorrhoea rates. The correlation between gonorrhoea and violent crime was significant at the P<0.001 level for every year from 1981 to 2010. Syphilis rates were also consistently correlated with violent crime rates. In contrast, the P-value for the correlation coefficient exceeded 0.05 in 9 of the 30 years for the association between gonorrhoea and poverty, and in 17 of the 30 years for that between gonorrhoea and unemployment. Because violent crime is associated with many social determinants of STIs and because it is consistently associated with STI rates, violent crime rates can be a useful proxy for the social determinants of health in statistical analyses of STI rates.
Salazar-Gutiérrez, María Luisa; Ochoa-Ponce, Cristina; Lona-Reyes, Juan Carlos; Gutiérrez-Íñiguez, Sara Ivonne
Reference methods for the quantification of the glomerular filtration rate (GFR) are difficult to use in clinical practice; formulas for evaluating GFR based on serum creatinine (SCr) and/or creatinine clearance are used. The aim of this study was to quantify the correlation and concordance of GFR with creatinine clearance in 24-hour urine (GFR24) and Schwartz and Schwartz updated formulas. Cross-sectional study involving healthy pediatric patients and with chronic kidney disease (CKD) from 5 to 16.9 years. Linear correlation between GFR 24 and two formulas was evaluated with the Pearson correlation coefficient (r) and intraclass correlation coefficient (ICC). We studied 134 patients, of which 59.7% were male. Mean age was 10.8 years. The average GFR24 was 140.34ml/min/1.73m 2 ; 34.3% (n=46) had GFR <90ml/min/1.73m 2 . Moderate linear correlation between GFR24 and Schwartz (r= 0.63) and Schwartz updated (r= 0.65) formulas was observed. There was good concordance between the GFR24 and Schwartz (ICC= 0.77) and updated Schwartz (ICC= 0.77) formulas. Schwartz classical formula in patients with GFR24 ≥ 90ml/min/1.73m 2 estimated higher values, while Schwartz updated underestimated values. There is moderate correlation and good concordance between the GFR24 and Schwartz and Schwartz updated formulas. The concordance was better in patients with obesity and lower in women, patients with hyperfiltration and normal weight. Copyright © 2016 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.
Iwasaki, Motoki; Mukai, Tomomi; Takachi, Ribeka; Ishihara, Junko; Totsuka, Yukari; Tsugane, Shoichiro
2014-08-01
Clarification of the putative etiologic role of heterocyclic aromatic amines (HAAs) in the development of cancer requires a validated assessment tool for dietary HAAs. This study primarily aimed to evaluate the validity of a food frequency questionnaire (FFQ) in estimating HAA intake, using 2-amino-1-methyl-6-phenylimidazo[4,5-b]pyridine (PhIP) level in human hair as the reference method. We first updated analytical methods of PhIP using liquid chromatography-electrospray ionization/tandem mass spectrometry (LC-ESI/MS/MS) and measured 44 fur samples from nine rats from a feeding study as part-verification of the quantitative performance of LC-ESI/MS/MS. We next measured PhIP level in human hair samples from a validation study of the FFQ (n = 65). HAA intake from the FFQ was estimated using information on intake from six fish items and seven meat items and data on HAA content in each food item. Correlation coefficients between PhIP level in human hair and HAA intake from the FFQ were calculated. The animal feeding study of PhIP found a significant dose-response relationship between dosage and PhIP in rat fur. Mean level was 53.8 pg/g hair among subjects with values over the limit of detection (LOD) (n = 57). We found significant positive correlation coefficients between PhIP in human hair and HAA intake from the FFQ, with Spearman rank correlation coefficients of 0.35 for all subjects, 0.21 for subjects with over LOD values, and 0.34 for subjects with over limit of quantification. Findings from the validation study suggest that the FFQ is reasonably valid for the assessment of HAA intake.
Kayihan, Gürhan; Özkan, Ali; Köklü, Yusuf; Eyuboğlu, Ender; Akça, Firat; Koz, Mitat; Ersöz, Gülfem
2014-04-01
The purpose of this study was to compare values of aerobic performance in the 1-mile run test (1-MRT) using different formulae. Aerobic capacities of 351 male volunteers working for the Turkish National Police within the age range of 20-23 years were evaluated by the 1-MRT and the 20-metre shuttle run (20-MST). VO2max values were estimated by the prediction equations developed by George et al. (1993), Cureton et al. (1995) and Kline et al. (1987) for the 1-MRT and by Leger and Lambert (1982) for the 20-MST. The difference between the results of the different formulae was significant (p = 0.000). The correlation coefficient between the estimated VO2max using Cureton's equation, George's equation, Kline's equation and the 20-MST were 0.691 (p < 0.001), 0.486 (p < 0.001) and 0.608 (p < 0.001), respectively. The highest correlation coefficient was between the VO2max estimated by the 20-MST and Cureton's equation. Similarly, the highest correlation coefficient (r = -0.779) was between the 1-mile run time and the VO2max estimated by Cureton's equation. When analysing more vigorous exercise than sub-maximal exercise, we suggest that Cureton's equation be used to predict the VO2max from 1-mile run/walk performance in large numbers of healthy individuals with high VO2max. This research compares the use of 3 different formulae to estimate VO2max from 1-mile run/walk performance in male law enforcement officers aged 20-23 years for the first time and reports the most accurate formula to use when evaluating aerobic capacities of large numbers of healthy individuals.