Sample records for correlation coefficients determined

  1. Determining Sample Size for Accurate Estimation of the Squared Multiple Correlation Coefficient.

    ERIC Educational Resources Information Center

    Algina, James; Olejnik, Stephen

    2000-01-01

    Discusses determining sample size for estimation of the squared multiple correlation coefficient and presents regression equations that permit determination of the sample size for estimating this parameter for up to 20 predictor variables. (SLD)

  2. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures

    PubMed Central

    Someswara Rao, Chinta; Viswanadha Raju, S.

    2016-01-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc. PMID:26981409

  3. Similarity analysis between chromosomes of Homo sapiens and monkeys with correlation coefficient, rank correlation coefficient and cosine similarity measures.

    PubMed

    Someswara Rao, Chinta; Viswanadha Raju, S

    2016-03-01

    In this paper, we consider correlation coefficient, rank correlation coefficient and cosine similarity measures for evaluating similarity between Homo sapiens and monkeys. We used DNA chromosomes of genome wide genes to determine the correlation between the chromosomal content and evolutionary relationship. The similarity among the H. sapiens and monkeys is measured for a total of 210 chromosomes related to 10 species. The similarity measures of these different species show the relationship between the H. sapiens and monkey. This similarity will be helpful at theft identification, maternity identification, disease identification, etc.

  4. Thermal expansion coefficient determination of polylactic acid using digital image correlation

    NASA Astrophysics Data System (ADS)

    Botean, Adrian-Ioan

    2018-02-01

    This paper aims determining the linear thermal expansion coefficient (CTE) of polylactic acid (PLA) using an optical method for measuring deformations called digital image correlation method (DIC). Because PLA is often used in making many pieces with 3D printing technology, it is opportune to know this coefficient to obtain a higher degree of precision in the construction of parts and to monitor deformations when these parts are subjected to a thermal gradient. Are used two PLA discs with 20 and 40% degree of filling. In parallel with this approach was determined the linear thermal expansion coefficient (CTE) for the copper cylinder on the surface of which are placed the two discs of PLA.

  5. Equations of prediction for abdominal fat in brown egg-laying hens fed different diets.

    PubMed

    Souza, C; Jaimes, J J B; Gewehr, C E

    2017-06-01

    The objective was to use noninvasive measurements to formulate equations for predicting the abdominal fat weight of laying hens in a noninvasive manner. Hens were fed with different diets; the external body measurements of birds were used as regressors. We used 288 Hy-Line Brown laying hens, distributed in a completely randomized design in a factorial arrangement, submitted for 16 wk to 2 metabolizable energy levels (2,550 and 2,800 kcal/kg) and 3 levels of crude protein in the diet (150, 160, and 170 g/kg), totaling 6 treatments, with 48 hens each. Sixteen hens per treatment of 92 wk age were utilized to evaluate body weight, bird length, tarsus and sternum, greater and lesser diameter of the tarsus, and abdominal fat weight, after slaughter. The equations were obtained by using measures evaluated with regressors through simple and multiple linear regression with the stepwise method of indirect elimination (backward), with P < 0.10 for all variables remaining in the model. The weight of abdominal fat as predicted by the equations and observed values for each bird were subjected to Pearson's correlation analysis. The equations generated by energy levels showed coefficients of determination of 0.50 and 0.74 for 2,800 and 2,550 kcal/kg of metabolizable energy, respectively, with correlation coefficients of 0.71 and 0.84, with a highly significant correlation between the calculated and observed values of abdominal fat. For protein levels of 150, 160, and 170 g/kg in the diet, it was possible to obtain coefficients of determination of 0.75, 0.57, and 0.61, with correlation coefficients of 0.86, 0.75, and 0.78, respectively. Regarding the general equation for predicting abdominal fat weight, the coefficient of determination was 0.62; the correlation coefficient was 0.79. The equations for predicting abdominal fat weight in laying hens, based on external measurements of the birds, showed positive coefficients of determination and correlation coefficients, thus allowing researchers to determine abdominal fat weight in vivo. © 2016 Poultry Science Association Inc.

  6. [Correlation coefficient-based classification method of hydrological dependence variability: With auto-regression model as example].

    PubMed

    Zhao, Yu Xi; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi

    2018-04-01

    Hydrological process evaluation is temporal dependent. Hydrological time series including dependence components do not meet the data consistency assumption for hydrological computation. Both of those factors cause great difficulty for water researches. Given the existence of hydrological dependence variability, we proposed a correlationcoefficient-based method for significance evaluation of hydrological dependence based on auto-regression model. By calculating the correlation coefficient between the original series and its dependence component and selecting reasonable thresholds of correlation coefficient, this method divided significance degree of dependence into no variability, weak variability, mid variability, strong variability, and drastic variability. By deducing the relationship between correlation coefficient and auto-correlation coefficient in each order of series, we found that the correlation coefficient was mainly determined by the magnitude of auto-correlation coefficient from the 1 order to p order, which clarified the theoretical basis of this method. With the first-order and second-order auto-regression models as examples, the reasonability of the deduced formula was verified through Monte-Carlo experiments to classify the relationship between correlation coefficient and auto-correlation coefficient. This method was used to analyze three observed hydrological time series. The results indicated the coexistence of stochastic and dependence characteristics in hydrological process.

  7. Distance correlation methods for discovering associations in large astrophysical databases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martínez-Gómez, Elizabeth; Richards, Mercedes T.; Richards, Donald St. P., E-mail: elizabeth.martinez@itam.mx, E-mail: mrichards@astro.psu.edu, E-mail: richards@stat.psu.edu

    2014-01-20

    High-dimensional, large-sample astrophysical databases of galaxy clusters, such as the Chandra Deep Field South COMBO-17 database, provide measurements on many variables for thousands of galaxies and a range of redshifts. Current understanding of galaxy formation and evolution rests sensitively on relationships between different astrophysical variables; hence an ability to detect and verify associations or correlations between variables is important in astrophysical research. In this paper, we apply a recently defined statistical measure called the distance correlation coefficient, which can be used to identify new associations and correlations between astrophysical variables. The distance correlation coefficient applies to variables of any dimension,more » can be used to determine smaller sets of variables that provide equivalent astrophysical information, is zero only when variables are independent, and is capable of detecting nonlinear associations that are undetectable by the classical Pearson correlation coefficient. Hence, the distance correlation coefficient provides more information than the Pearson coefficient. We analyze numerous pairs of variables in the COMBO-17 database with the distance correlation method and with the maximal information coefficient. We show that the Pearson coefficient can be estimated with higher accuracy from the corresponding distance correlation coefficient than from the maximal information coefficient. For given values of the Pearson coefficient, the distance correlation method has a greater ability than the maximal information coefficient to resolve astrophysical data into highly concentrated horseshoe- or V-shapes, which enhances classification and pattern identification. These results are observed over a range of redshifts beyond the local universe and for galaxies from elliptical to spiral.« less

  8. AN EMPIRICAL INVESTIGATION OF THE EFFECTS OF NONNORMALITY UPON THE SAMPLING DISTRIBUTION OF THE PROJECT MOMENT CORRELATION COEFFICIENT.

    ERIC Educational Resources Information Center

    HJELM, HOWARD; NORRIS, RAYMOND C.

    THE STUDY EMPIRICALLY DETERMINED THE EFFECTS OF NONNORMALITY UPON SOME SAMPLING DISTRIBUTIONS OF THE PRODUCT MOMENT CORRELATION COEFFICIENT (PMCC). SAMPLING DISTRIBUTIONS OF THE PMCC WERE OBTAINED BY DRAWING NUMEROUS SAMPLES FROM CONTROL AND EXPERIMENTAL POPULATIONS HAVING VARIOUS DEGREES OF NONNORMALITY AND BY CALCULATING CORRELATION COEFFICIENTS…

  9. Experimental determination of turbulence in a GH2-GOX rocket combustion chamber

    NASA Technical Reports Server (NTRS)

    Tou, P.; Russell, R.; Ohara, J.

    1974-01-01

    The intensity of turbulence and the Lagrangian correlation coefficient for a gaseous rocket combustion chamber have been determined from the experimental measurements of the tracer gas diffusion. A combination of Taylor's turbulent diffusion theory and Spalding's numerical method for solving the conservation equations of fluid mechanics was used to calculate these quantities. Taylor's theory was extended to consider the inhomogeneity of the turbulence field in the axial direction of the combustion chamber. An exponential function was used to represent the Lagrangian correlation coefficient. The results indicate that the maximum value of the intensity of turbulence is about 15% and the Lagrangian correlation coefficient drops to about 0.12 in one inch of the chamber length.

  10. SCI model structure determination program (OSR) user's guide. [optimal subset regression

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The computer program, OSR (Optimal Subset Regression) which estimates models for rotorcraft body and rotor force and moment coefficients is described. The technique used is based on the subset regression algorithm. Given time histories of aerodynamic coefficients, aerodynamic variables, and control inputs, the program computes correlation between various time histories. The model structure determination is based on these correlations. Inputs and outputs of the program are given.

  11. Statistical Study of Turbulence: Spectral Functions and Correlation Coefficients

    NASA Technical Reports Server (NTRS)

    Frenkiel, Francois N.

    1958-01-01

    In reading the publications on turbulence of different authors, one often runs the risk of confusing the various correlation coefficients and turbulence spectra. We have made a point of defining, by appropriate concepts, the differences which exist between these functions. Besides, we introduce in the symbols a few new characteristics of turbulence. In the first chapter, we study some relations between the correlation coefficients and the different turbulence spectra. Certain relations are given by means of demonstrations which could be called intuitive rather than mathematical. In this way we demonstrate that the correlation coefficients between the simultaneous turbulent velocities at two points are identical, whether studied in Lagrange's or in Euler's systems. We then consider new spectra of turbulence, obtained by study of the simultaneous velocities along a straight line of given direction. We determine some relations between these spectra and the correlation coefficients. Examining the relation between the spectrum of the turbulence measured at a fixed point and the longitudinal-correlation curve given by G. I. Taylor, we find that this equation is exact only when the coefficient is very small.

  12. Inferential Procedures for Correlation Coefficients Corrected for Attenuation.

    ERIC Educational Resources Information Center

    Hakstian, A. Ralph; And Others

    1988-01-01

    A model and computation procedure based on classical test score theory are presented for determination of a correlation coefficient corrected for attenuation due to unreliability. Delta and Monte Carlo method applications are discussed. A power analysis revealed no serious loss in efficiency resulting from correction for attentuation. (TJH)

  13. A Pilot Study of the Snap & Sniff Threshold Test.

    PubMed

    Jiang, Rong-San; Liang, Kai-Li

    2018-05-01

    The Snap & Sniff ® Threshold Test (S&S) has been recently developed to determine the olfactory threshold. The aim of this study was to further evaluate the validity and test-retest reliability of the S&S. The olfactory thresholds of 120 participants were determined using both the Smell Threshold Test (STT) and the S&S. The participants included 30 normosmic volunteers and 90 patients (60 hyposmic, 30 anosmic). The normosmic participants were retested using the STT and S&S at an intertest interval of at least 1 day. The mean olfactory threshold determined with the S&S was -6.76 for the normosmic participants, -3.79 for the hyposmic patients, and -2 for the anosmic patients. The olfactory thresholds were significantly different across the 3 groups ( P < .001). Snap & Sniff-based and STT-based olfactory thresholds were correlated weakly in the normosmic group (correlation coefficient = 0.162, P = .391) but more strongly correlated in the patient groups (hyposmic: correlation coefficient = 0.376, P = .003; anosmic: correlation coefficient = 1.0). The test-retest correlation for the S&S-based olfactory thresholds was 0.384 ( P = .036). Based on validity and test-retest reliability, we concluded that the S&S is a proper test for olfactory thresholds.

  14. Evaluation of estimation methods for organic carbon normalized sorption coefficients

    USGS Publications Warehouse

    Baker, James R.; Mihelcic, James R.; Luehrs, Dean C.; Hickey, James P.

    1997-01-01

    A critically evaluated set of 94 soil water partition coefficients normalized to soil organic carbon content (Koc) is presented for 11 classes of organic chemicals. This data set is used to develop and evaluate Koc estimation methods using three different descriptors. The three types of descriptors used in predicting Koc were octanol/water partition coefficient (Kow), molecular connectivity (mXt) and linear solvation energy relationships (LSERs). The best results were obtained estimating Koc from Kow, though a slight improvement in the correlation coefficient was obtained by using a two-parameter regression with Kow and the third order difference term from mXt. Molecular connectivity correlations seemed to be best suited for use with specific chemical classes. The LSER provided a better fit than mXt but not as good as the correlation with Koc. The correlation to predict Koc from Kow was developed for 72 chemicals; log Koc = 0.903* log Kow + 0.094. This correlation accounts for 91% of the variability in the data for chemicals with log Kow ranging from 1.7 to 7.0. The expression to determine the 95% confidence interval on the estimated Koc is provided along with an example for two chemicals of different hydrophobicity showing the confidence interval of the retardation factor determined from the estimated Koc. The data showed that Koc is not likely to be applicable for chemicals with log Kow < 1.7. Finally, the Koc correlation developed using Kow as a descriptor was compared with three nonclass-specific correlations and two 'commonly used' class-specific correlations to determine which method(s) are most suitable.

  15. Partition coefficients of organic compounds in lipid-water systems and correlations with fish bioconcentration factors

    USGS Publications Warehouse

    Chiou, C.T.

    1985-01-01

    Triolein-water partition coefficients (KtW) have been determined for 38 slightly water-soluble organic compounds, and their magnitudes have been compared with the corresponding octanol-water partition coefficients (KOW). In the absence of major solvent-solute interaction effects in the organic solvent phase, the conventional treatment (based on Raoult's law) predicts sharply lower partition coefficients for most of the solutes in triolein because of its considerably higher molecular weight, whereas the Flory-Huggins treatment predicts higher partition coefficients with triolein. The data are in much better agreement with the Flory-Huggins model. As expected from the similarity in the partition coefficients, the water solubility (which was previously found to be the major determinant of the KOW) is also the major determinant for the Ktw. When the published BCF values (bioconcentration factors) of organic compounds in fish are based on the lipid content rather than on total mass, they are approximately equal to the Ktw, which suggests at least near equilibrium for solute partitioning between water and fish lipid. The close correlation between Ktw and Kow suggests that Kow is also a good predictor for lipid-water partition coefficients and bioconcentration factors.

  16. Comparison of RNFL thickness and RPE-normalized RNFL attenuation coefficient for glaucoma diagnosis

    NASA Astrophysics Data System (ADS)

    Vermeer, K. A.; van der Schoot, J.; Lemij, H. G.; de Boer, J. F.

    2013-03-01

    Recently, a method to determine the retinal nerve fiber layer (RNFL) attenuation coefficient, based on normalization on the retinal pigment epithelium, was introduced. In contrast to conventional RNFL thickness measures, this novel measure represents a scattering property of the RNFL tissue. In this paper, we compare the RNFL thickness and the RNFL attenuation coefficient on 10 normal and 8 glaucomatous eyes by analyzing the correlation coefficient and the receiver operator curves (ROCs). The thickness and attenuation coefficient showed moderate correlation (r=0.82). Smaller correlation coefficients were found within normal (r=0.55) and glaucomatous (r=0.48) eyes. The full separation between normal and glaucomatous eyes based on the RNFL attenuation coefficient yielded an area under the ROC (AROC) of 1.0. The AROC for the RNFL thickness was 0.9875. No statistically significant difference between the two measures was found by comparing the AROC. RNFL attenuation coefficients may thus replace current RNFL thickness measurements or be combined with it to improve glaucoma diagnosis.

  17. Correlation Between Geometric Similarity of Ice Shapes and the Resulting Aerodynamic Performance Degradation: A Preliminary Investigation Using WIND

    NASA Technical Reports Server (NTRS)

    Wright, William B.; Chung, James

    1999-01-01

    Aerodynamic performance calculations were performed using WIND on ten experimental ice shapes and the corresponding ten ice shapes predicted by LEWICE 2.0. The resulting data for lift coefficient and drag coefficient are presented. The difference in aerodynamic results between the experimental ice shapes and the LEWICE ice shapes were compared to the quantitative difference in ice shape geometry presented in an earlier report. Correlations were generated to determine the geometric features which have the most effect on performance degradation. Results show that maximum lift and stall angle can be correlated to the upper horn angle and the leading edge minimum thickness. Drag coefficient can be correlated to the upper horn angle and the frequency-weighted average of the Fourier coefficients. Pitching moment correlated with the upper horn angle and to a much lesser extent to the upper and lower horn thicknesses.

  18. A comparison of confidence interval methods for the intraclass correlation coefficient in community-based cluster randomization trials with a binary outcome.

    PubMed

    Braschel, Melissa C; Svec, Ivana; Darlington, Gerarda A; Donner, Allan

    2016-04-01

    Many investigators rely on previously published point estimates of the intraclass correlation coefficient rather than on their associated confidence intervals to determine the required size of a newly planned cluster randomized trial. Although confidence interval methods for the intraclass correlation coefficient that can be applied to community-based trials have been developed for a continuous outcome variable, fewer methods exist for a binary outcome variable. The aim of this study is to evaluate confidence interval methods for the intraclass correlation coefficient applied to binary outcomes in community intervention trials enrolling a small number of large clusters. Existing methods for confidence interval construction are examined and compared to a new ad hoc approach based on dividing clusters into a large number of smaller sub-clusters and subsequently applying existing methods to the resulting data. Monte Carlo simulation is used to assess the width and coverage of confidence intervals for the intraclass correlation coefficient based on Smith's large sample approximation of the standard error of the one-way analysis of variance estimator, an inverted modified Wald test for the Fleiss-Cuzick estimator, and intervals constructed using a bootstrap-t applied to a variance-stabilizing transformation of the intraclass correlation coefficient estimate. In addition, a new approach is applied in which clusters are randomly divided into a large number of smaller sub-clusters with the same methods applied to these data (with the exception of the bootstrap-t interval, which assumes large cluster sizes). These methods are also applied to a cluster randomized trial on adolescent tobacco use for illustration. When applied to a binary outcome variable in a small number of large clusters, existing confidence interval methods for the intraclass correlation coefficient provide poor coverage. However, confidence intervals constructed using the new approach combined with Smith's method provide nominal or close to nominal coverage when the intraclass correlation coefficient is small (<0.05), as is the case in most community intervention trials. This study concludes that when a binary outcome variable is measured in a small number of large clusters, confidence intervals for the intraclass correlation coefficient may be constructed by dividing existing clusters into sub-clusters (e.g. groups of 5) and using Smith's method. The resulting confidence intervals provide nominal or close to nominal coverage across a wide range of parameters when the intraclass correlation coefficient is small (<0.05). Application of this method should provide investigators with a better understanding of the uncertainty associated with a point estimator of the intraclass correlation coefficient used for determining the sample size needed for a newly designed community-based trial. © The Author(s) 2015.

  19. Correlations between symptoms, nasal endoscopy, and in-office computed tomography in post-surgical chronic rhinosinusitis patients.

    PubMed

    Ryan, William R; Ramachandra, Tara; Hwang, Peter H

    2011-03-01

    To determine correlations between symptoms, nasal endoscopy findings, and computed tomography (CT) scan findings in post-surgical chronic rhinosinusitis (CRS) patients. Cross-sectional. A total of 51 CRS patients who had undergone endoscopic sinus surgery (ESS) completed symptom questionnaires, underwent endoscopy, and received an in-office sinus CT scan during one clinic visit. For metrics, we used the Sinonasal Outcomes Test-20 (SNOT-20) questionnaire, visual analog symptom scale (VAS), Lund-Kennedy endoscopy scoring scale, and Lund-MacKay (LM) CT scoring scale. We determined Pearson correlation coefficients, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) between scores for symptoms, endoscopy, and CT. The SNOT-20 score and most VAS symptoms had poor correlation coefficients with both endoscopy and CT scores (0.03-0.24). Nasal drainage of pus, nasal congestion, and impaired sense of smell had moderate correlation coefficients with endoscopy and CT (0.24-0.42). Endoscopy had a strong correlation coefficient with CT (0.76). Drainage, edema, and polyps had strong correlation coefficients with CT (0.80, 0.69, and 0.49, respectively). Endoscopy had a PPV of 92.5% and NPV of 45.5% for detecting an abnormal sinus CT (LM score ≥1). In post-ESS CRS patients, most symptoms do not correlate well with either endoscopy or CT findings. Endoscopy and CT scores correlate well. Abnormal endoscopy findings have the ability to confidently rule in the presence of CT opacification, thus validating the importance of endoscopy in clinical decision making. However, a normal endoscopy cannot assure a normal CT. Thus, symptoms, endoscopy, and CT are complementary in the evaluation of the post-ESS CRS patient. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc., Rhinological, and Otological Society, Inc.

  20. Correlation among chronologic age, skeletal maturity, and dental age.

    PubMed

    Sukhia, Rashna H; Fida, Mubassar

    2010-01-01

    To determine the correlation among chronologic age, skeletal maturity, and dental age in reference to both sexes. In 380 subjects (147 males and 233 females) between 7 and 17 years of age, skeletal maturity was assessed using the cervical vertebral maturation stages described by Baccetti et al. Dental age was determined using the Demirjian method. The correlation between skeletal maturity and chronologic age on one side and between skeletal maturity and dental age on the other was assessed with Spearman rank correlation coefficients. Pearson correlation coefficients were used to assess the correlation between chronologic and dental age. For both sexes, significant correlations among chronologic age, skeletal maturity, and dental age were found. The mandibular first premolar had the highest correlation with skeletal maturation in both sexes. As skeletal maturity and dental age are significantly correlated, tooth development may be used to assess a patient's skeletal maturity at an early age. © 2011 BY QUINTESSENCE PUBLISHING CO, INC.

  1. Coarse-grained hydrodynamics from correlation functions

    NASA Astrophysics Data System (ADS)

    Palmer, Bruce

    2018-02-01

    This paper will describe a formalism for using correlation functions between different grid cells as the basis for determining coarse-grained hydrodynamic equations for modeling the behavior of mesoscopic fluid systems. Configurations from a molecular dynamics simulation or other atomistic simulation are projected onto basis functions representing grid cells in a continuum hydrodynamic simulation. Equilibrium correlation functions between different grid cells are evaluated from the molecular simulation and used to determine the evolution operator for the coarse-grained hydrodynamic system. The formalism is demonstrated on a discrete particle simulation of diffusion with a spatially dependent diffusion coefficient. Correlation functions are calculated from the particle simulation and the spatially varying diffusion coefficient is recovered using a fitting procedure.

  2. Comprehensive analysis of correlation coefficients estimated from pooling heterogeneous microarray data

    PubMed Central

    2013-01-01

    Background The synthesis of information across microarray studies has been performed by combining statistical results of individual studies (as in a mosaic), or by combining data from multiple studies into a large pool to be analyzed as a single data set (as in a melting pot of data). Specific issues relating to data heterogeneity across microarray studies, such as differences within and between labs or differences among experimental conditions, could lead to equivocal results in a melting pot approach. Results We applied statistical theory to determine the specific effect of different means and heteroskedasticity across 19 groups of microarray data on the sign and magnitude of gene-to-gene Pearson correlation coefficients obtained from the pool of 19 groups. We quantified the biases of the pooled coefficients and compared them to the biases of correlations estimated by an effect-size model. Mean differences across the 19 groups were the main factor determining the magnitude and sign of the pooled coefficients, which showed largest values of bias as they approached ±1. Only heteroskedasticity across the pool of 19 groups resulted in less efficient estimations of correlations than did a classical meta-analysis approach of combining correlation coefficients. These results were corroborated by simulation studies involving either mean differences or heteroskedasticity across a pool of N > 2 groups. Conclusions The combination of statistical results is best suited for synthesizing the correlation between expression profiles of a gene pair across several microarray studies. PMID:23822712

  3. Experimental determination of the turbulence in a liquid rocket combustion chamber

    NASA Technical Reports Server (NTRS)

    Hara, J.; Smith, L. O.; Partus, F. P.

    1972-01-01

    The intensity of turbulence and the Lagrangian correlation coefficient for a liquid rocket combustion chamber were determined experimentally using the tracer gas diffusion method. The results indicate that the turbulent diffusion process can be adequately modeled by the one-dimensional Taylor theory; however, the numerical values show significant disagreement with previously accepted values. The intensity of turbulence is higher by a factor of about two, while the Lagrangian correlation coefficient which was assumed to be unity in the past is much less than unity.

  4. Chemical and physical properties affecting strontium distribution coefficients of surficial-sediment samples at the Idaho National Engineering and Environmental Laboratory, Idaho

    USGS Publications Warehouse

    Liszewski, M.J.; Rosentreter, J.J.; Miller, Karl E.; Bartholomay, R.C.

    2000-01-01

    The U.S. Geological Survey and Idaho State University, in cooperation with the U.S. Department of Energy, conducted a study to determine strontium distribution coefficients (K(d)s) of surficial sediments at the Idaho National Engineering and Environmental Laboratory (INEEL). Batch experiments using synthesized aqueous solutions were used to determine K(d)s, which describe the distribution of a solute between the solution and solid phase, of 20 surficial-sediment samples from the INEEL. The K(d)s for the 20 surficial-sediment samples ranged from 36 to 275 ml/g. Many properties of both the synthesized aqueous solutions and sediments used in the experiments also were determined. Solution properties determined were initial and equilibrium concentrations of calcium, magnesium, and strontium, pH and specific conductance, and initial concentrations of potassium and sodium. Sediment properties determined were grain-size distribution, bulk mineralogy, whole-rock major-oxide and strontium and barium concentrations, and Brunauer-Emmett-Teller (BET) surface area. Solution and sediment properties were correlated with strontium K(d)s of the 20 surficial sediments using Pearson correlation coefficients. Solution properties with the strongest correlations with strontium K(d)s were equilibrium pH and equilibrium calcium concentration correlation coefficients, 0.6598 and -0.6518, respectively. Sediment properties with the strongest correlations with strontium K(d)s were manganese oxide (MnO), BET surface area, and the >4.75-mm-grain-size fraction correlation coefficients, 0.7054, 0.7022, and -0.6660, respectively. Effects of solution properties on strontium K(d)s were interpreted as being due to competition among similarly charged and sized cations in solution for strontium-sorption sites; effects of sediment properties on strontium K(d)s were interpreted as being surface-area related. Multivariate analyses of these solution and sediment properties resulted in r2 values of 0.8071 when all five properties were used and 0.8043 when three properties, equilibrium pH, MnO, and BET surface area, were used.

  5. Challenge of assessing symptoms in seriously ill intensive care unit patients: can proxy reporters help?

    PubMed

    Puntillo, Kathleen A; Neuhaus, John; Arai, Shoshana; Paul, Steven M; Gropper, Michael A; Cohen, Neal H; Miaskowski, Christine

    2012-10-01

    Determine levels of agreement among intensive care unit patients and their family members, nurses, and physicians (proxies) regarding patients' symptoms and compare levels of mean intensity (i.e., the magnitude of a symptom sensation) and distress (i.e., the degree of emotionality that a symptom engenders) of symptoms among patients and proxy reporters. Prospective study of proxy reporters of symptoms in seriously ill patients. Two intensive care units in a tertiary medical center in the Western United States. Two hundred and forty-five intensive care unit patients, 243 family members, 103 nurses, and 92 physicians. None. On the basis of the magnitude of intraclass correlation coefficients, where coefficients from .35 to .78 are considered to be appropriately robust, correlation coefficients between patients' and family members' ratings met this criterion (≥.35) for intensity in six of ten symptoms. No intensity ratings between patients and nurses had intraclass correlation coefficients >.32. Three symptoms had intensity correlation coefficients of ≥.36 between patients' and physicians' ratings. Correlation coefficients between patients and family members were >.40 for five symptom-distress ratings. No symptoms had distress correlation coefficients of ≥.28 between patients' and nurses' ratings. Two symptoms had symptom-distress correlation coefficients between patients' and physicians' ratings at >.39. Family members, nurses, and physicians reported higher symptom-intensity scores than patients did for 80%, 60%, and 60% of the symptoms, respectively. Family members, nurses, and physicians reported higher symptom-distress scores than patients did for 90%, 70%, and 80% of the symptoms, respectively. Patient-family intraclass correlation coefficients were sufficiently close for us to consider using family members to help assess intensive care unit patients' symptoms. Relatively low intraclass correlation coefficients between intensive care unit clinicians' and patients' symptom ratings indicate that some proxy raters overestimate whereas others underestimate patients' symptoms. Proxy overestimation of patients' symptom scores warrants further study because this may influence decisions about treating patients' symptoms.

  6. Simultaneous characterization of lateral lipid and prothrombin diffusion coefficients by z-scan fluorescence correlation spectroscopy.

    PubMed

    Stefl, Martin; Kułakowska, Anna; Hof, Martin

    2009-08-05

    A new (to our knowledge) robust approach for the determination of lateral diffusion coefficients of weakly bound proteins is applied for the phosphatidylserine specific membrane interaction of bovine prothrombin. It is shown that z-scan fluorescence correlation spectroscopy in combination with pulsed interleaved dual excitation allows simultaneous monitoring of the lateral diffusion of labeled protein and phospholipids. Moreover, from the dependencies of the particle numbers on the axial sample positions at different protein concentrations phosphatidylserine-dependent equilibrium dissociation constants are derived confirming literature values. Increasing the amount of membrane-bound prothrombin retards the lateral protein and lipid diffusion, indicating coupling of both processes. The lateral diffusion coefficients of labeled lipids are considerably larger than the simultaneously determined lateral diffusion coefficients of prothrombin, which contradicts findings reported for the isolated N-terminus of prothrombin.

  7. Reliability and Validity of a Chinese-Translated Version of a Pregnancy Physical Activity Questionnaire.

    PubMed

    Xiang, Mi; Konishi, Massayuki; Hu, Huanhuan; Takahashi, Masaki; Fan, Wenbi; Nishimaki, Mio; Ando, Karina; Kim, Hyeon-Ki; Tabata, Hiroki; Arao, Takashi; Sakamoto, Shizuo

    2016-09-01

    Objectives The objectives of the present study were to translate the English version of the Pregnancy Physical Activity Questionnaire into Chinese (PPAQ-C) and to determine its reliability and validity for use by pregnant Chinese women. Methods The study included 224 pregnant women during their first, second, or third trimesters of pregnancy who completed the PPAQ-C on their first visit and wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd) for 7 days. One week after the first visit, we collected the data from the uniaxial accelerometer records, and the women were asked to complete the PPAQ-C again. Results We used intraclass correlation coefficients to determine the reliability of the PPAQ-C. The intraclass correlation coefficients were 0.77 for total activity (light and above), 0.76 for sedentary activity, 0.75 for light activity, 0.59 for moderate activity, and 0.28 for vigorous activity. The intraclass correlation coefficients were 0.74 for "household and caregiving", 0.75 for "occupational" activities, and 0.34 for "sports/exercise". Validity between the PPAQ-C and accelerometer data was determined by Spearman correlation coefficients. Although there were no significant correlations for moderate activity (r = 0.19, P > 0.05) or vigorous activity (r = 0.15, P > 0.05), there were significant correlations for total activity [light and above; r = 0.35, P < 0.01)] and for light activity (r = 0.33, P < 0.01). Conclusions for Practice The PPAQ-C is reliable and moderately accurate for measuring physical activity in pregnant Chinese women.

  8. Investigation of oscillating cascade aerodynamics by an experimental influence coefficient technique

    NASA Technical Reports Server (NTRS)

    Buffum, Daniel H.; Fleeter, Sanford

    1988-01-01

    Fundamental experiments are performed in the NASA Lewis Transonic Oscillating Cascade Facility to investigate the torsion mode unsteady aerodynamics of a biconvex airfoil cascade at realistic values of the reduced frequency for all interblade phase angles at a specified mean flow condition. In particular, an unsteady aerodynamic influence coefficient technique is developed and utilized in which only one airfoil in the cascade is oscillated at a time and the resulting airfoil surface unsteady pressure distribution measured on one dynamically instrumented airfoil. The unsteady aerodynamics of an equivalent cascade with all airfoils oscillating at a specified interblade phase angle are then determined through a vector summation of these data. These influence coefficient determined oscillation cascade data are correlated with data obtained in this cascade with all airfoils oscillating at several interblade phase angle values. The influence coefficients are then utilized to determine the unsteady aerodynamics of the cascade for all interblade phase angles, with these unique data subsequently correlated with predictions from a linearized unsteady cascade model.

  9. Supersymmetric contributions to weak decay correlation coefficients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Profumo, S.; Ramsey-Musolf, M. J.; Tulin, S.

    2007-04-01

    We study supersymmetric contributions to correlation coefficients that characterize the spectral shape and angular distribution for polarized {mu}- and {beta}-decays. In the minimal supersymmetric standard model (MSSM), one-loop box graphs containing superpartners can give rise to non-(V-Ax(V-A) four-fermion operators in the presence of left-right or flavor mixing between sfermions. We analyze the present phenomenological constraints on such mixing and determine the range of allowed contributions to the weak decay correlation coefficients. We discuss the prospective implications for future {mu}- and {beta}-decay experiments, and argue that they may provide unique probes of left-right mixing in the first generation scalar fermion sector.

  10. VizieR Online Data Catalog: Fermi/GBM GRB time-resolved spectral catalog (Yu+, 2016)

    NASA Astrophysics Data System (ADS)

    Yu, H.-F.; Preece, R. D.; Greiner, J.; Bhat, P. N.; Bissaldi, E.; Briggs, M. S.; Cleveland, W. H.; Connaughton, V.; Goldstein, A.; von Kienlin; A.; Kouveliotou, C.; Mailyan, B.; Meegan, C. A.; Paciesas, W. S.; Rau, A.; Roberts, O. J.; Veres, P.; Wilson-Hodge, C.; Zhang, B.-B.; van Eerten, H. J.

    2016-01-01

    Time-resolved spectral analysis results of BEST models: for each spectrum GRB name using the Fermi GBM trigger designation, spectrum number within individual burst, start time Tstart and end time Tstop for the time bin, BEST model, best-fit parameters of the BEST model, value of CSTAT per degrees of freedom, 10keV-1MeV photon and energy flux are given. Ep evolutionary trends: for each burst GRB name, number of spectra with Ep, Spearman's Rank Correlation Coefficients between Ep_ and photon flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficients between Ep and energy flux and 90%, 95%, and 99% confidence intervals, Spearman's Rank Correlation Coefficient between Ep and time and 90%, 95%, and 99% confidence intervals, trends as determined by computer for 90%, 95%, and 99% confidence intervals, trends as determined by human eyes are given. (2 data files).

  11. Determination of diffusion coefficients of various livestock antibiotics in water at infinite dilution

    NASA Astrophysics Data System (ADS)

    Soriano, Allan N.; Adamos, Kristoni G.; Bonifacio, Pauline B.; Adornado, Adonis P.; Bungay, Vergel C.; Vairavan, Rajendaran

    2017-11-01

    The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic's anion.

  12. Size exclusion chromatography and viscometry in paper degradation studies. New Mark-Houwink coefficients for cellulose in cupri-ethylenediamine.

    PubMed

    Łojewski, Tomasz; Zieba, Katarzyna; Lojewska, Joanna

    2010-10-15

    The paper deals with the application of size exclusion chromatography (SEC) for the studies of paper degradation phenomena. The goal is to solve some of the technical problems connected with the calibration of multi-detector SEC system and to find the correlation between SEC and viscometric results of degree of polymerization of cellulose. The results gathered for the paper samples degraded by acidic air pollutant (NO(2)) are used as an example of SEC-MALLS application. From the correlation between intrinsic viscosities and absolute value of molecular masses obtained with SEC/MALLS (Multi Angle Laser Light Scattering) technique, Mark-Houwink coefficients for cellulose in cupri-ethylenediamine solution were determined. Thus obtained coefficients were used for the determination of viscometric degree of polymerization (molecular mass) of the aged samples. An excellent correlation was found between the chromatographic values of molecular masses obtained with SEC-UV/VIS detection and the viscometric ones utilizing the improved values of Mark-Houwink coefficients. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Time-lag of the earthquake energy release between three seismic regions

    NASA Astrophysics Data System (ADS)

    Tsapanos, Theodoros M.; Liritzis, Ioannis

    1992-06-01

    Three complete data sets of strong earthquakes ( M≥5.5), which occurred in the seismic regions of Chile, Mexico and Kamchatka during the time period 1899 1985, have been used to test the existence of a time-lag in the seismic energy release between these regions. These data sets were cross-correlated in order to determine whether any pair of the sets are correlated. For this purpose statistical tests, such as the T-test, the Fisher's transformation and probability distribution have been applied to determine the significance of the obtained correlation coefficients. The results show that the time-lag between Chile and Kamchatka is -2, which means that Kamchatka precedes Chile by 2 years, with a correlation coefficient significant at 99.80% level, a weak correlation between Kamchatka-Mexico and noncorrelation for Mexico-Chile.

  14. Determining Learning Disabilities in Mathematics.

    ERIC Educational Resources Information Center

    Dunlap, William P.; And Others

    1979-01-01

    To determine the generalizability of reading expectancy formulas in ascertaining mathematics expectancy levels, correlation coefficients were computed between the scores of 150 Ss (7 to 12 years old) with learning problems on standardized mathematics and reading tests and expectancy scores. Formulas correlated higher with Ss' actual mathematics…

  15. Influence of structure properties on protein-protein interactions-QSAR modeling of changes in diffusion coefficients.

    PubMed

    Bauer, Katharina Christin; Hämmerling, Frank; Kittelmann, Jörg; Dürr, Cathrin; Görlich, Fabian; Hubbuch, Jürgen

    2017-04-01

    Information about protein-protein interactions provides valuable knowledge about the phase behavior of protein solutions during the biopharmaceutical production process. Up to date it is possible to capture their overall impact by an experimentally determined potential of mean force. For the description of this potential, the second virial coefficient B22, the diffusion interaction parameter kD, the storage modulus G', or the diffusion coefficient D is applied. In silico methods do not only have the potential to predict these parameters, but also to provide deeper understanding of the molecular origin of the protein-protein interactions by correlating the data to the protein's three-dimensional structure. This methodology furthermore allows a lower sample consumption and less experimental effort. Of all in silico methods, QSAR modeling, which correlates the properties of the molecule's structure with the experimental behavior, seems to be particularly suitable for this purpose. To verify this, the study reported here dealt with the determination of a QSAR model for the diffusion coefficient of proteins. This model consisted of diffusion coefficients for six different model proteins at various pH values and NaCl concentrations. The generated QSAR model showed a good correlation between experimental and predicted data with a coefficient of determination R2 = 0.9 and a good predictability for an external test set with R2 = 0.91. The information about the properties affecting protein-protein interactions present in solution was in agreement with experiment and theory. Furthermore, the model was able to give a more detailed picture of the protein properties influencing the diffusion coefficient and the acting protein-protein interactions. Biotechnol. Bioeng. 2017;114: 821-831. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Colocalization analysis in fluorescence micrographs: verification of a more accurate calculation of pearson's correlation coefficient.

    PubMed

    Barlow, Andrew L; Macleod, Alasdair; Noppen, Samuel; Sanderson, Jeremy; Guérin, Christopher J

    2010-12-01

    One of the most routine uses of fluorescence microscopy is colocalization, i.e., the demonstration of a relationship between pairs of biological molecules. Frequently this is presented simplistically by the use of overlays of red and green images, with areas of yellow indicating colocalization of the molecules. Colocalization data are rarely quantified and can be misleading. Our results from both synthetic and biological datasets demonstrate that the generation of Pearson's correlation coefficient between pairs of images can overestimate positive correlation and fail to demonstrate negative correlation. We have demonstrated that the calculation of a thresholded Pearson's correlation coefficient using only intensity values over a determined threshold in both channels produces numerical values that more accurately describe both synthetic datasets and biological examples. Its use will bring clarity and accuracy to colocalization studies using fluorescent microscopy.

  17. Estimation of soil-soil solution distribution coefficient of radiostrontium using soil properties.

    PubMed

    Ishikawa, Nao K; Uchida, Shigeo; Tagami, Keiko

    2009-02-01

    We propose a new approach for estimation of soil-soil solution distribution coefficient (K(d)) of radiostrontium using some selected soil properties. We used 142 Japanese agricultural soil samples (35 Andosol, 25 Cambisol, 77 Fluvisol, and 5 others) for which Sr-K(d) values had been determined by a batch sorption test and listed in our database. Spearman's rank correlation test was carried out to investigate correlations between Sr-K(d) values and soil properties. Electrical conductivity and water soluble Ca had good correlations with Sr-K(d) values for all soil groups. Then, we found a high correlation between the ratio of exchangeable Ca to Ca concentration in water soluble fraction and Sr-K(d) values with correlation coefficient R=0.72. This pointed us toward a relatively easy way to estimate Sr-K(d) values.

  18. Repeatability of chemical-shift-encoded water-fat MRI and diffusion-tensor imaging in lower extremity muscles in children.

    PubMed

    Ponrartana, Skorn; Andrade, Kristine E; Wren, Tishya A L; Ramos-Platt, Leigh; Hu, Houchun H; Bluml, Stefan; Gilsanz, Vicente

    2014-06-01

    The purpose of this study was to assess the repeatability of water-fat MRI and diffusion-tensor imaging (DTI) as quantitative biomarkers of pediatric lower extremity skeletal muscle. MRI at 3 T of a randomly selected thigh and lower leg of seven healthy children was studied using water-fat separation and DTI techniques. Muscle-fat fraction, apparent diffusion coefficient (ADC), and fractional anisotropy (FA) values were calculated. Test-retest and interrater repeatability were assessed by calculating the Pearson correlation coefficient, intraclass correlation coefficient, and Bland-Altman analysis. Bland-Altman plots show that the mean difference between test-retest and interrater measurements of muscle-fat fraction, ADC, and FA was near 0. The correlation coefficients and intraclass correlation coefficients were all between 0.88 and 0.99 (p < 0.05), suggesting excellent reliability of the measurements. Muscle-fat fraction measurements from water-fat MRI exhibited the highest intraclass correlation coefficient. Interrater agreement was consistently better than test-retest comparisons. Water-fat MRI and DTI measurements in lower extremity skeletal muscles are objective repeatable biomarkers in children. This knowledge should aid in the understanding of the number of participants needed in clinical trials when using these determinations as an outcome measure to noninvasively monitor neuromuscular disease.

  19. Investigating bias in squared regression structure coefficients

    PubMed Central

    Nimon, Kim F.; Zientek, Linda R.; Thompson, Bruce

    2015-01-01

    The importance of structure coefficients and analogs of regression weights for analysis within the general linear model (GLM) has been well-documented. The purpose of this study was to investigate bias in squared structure coefficients in the context of multiple regression and to determine if a formula that had been shown to correct for bias in squared Pearson correlation coefficients and coefficients of determination could be used to correct for bias in squared regression structure coefficients. Using data from a Monte Carlo simulation, this study found that squared regression structure coefficients corrected with Pratt's formula produced less biased estimates and might be more accurate and stable estimates of population squared regression structure coefficients than estimates with no such corrections. While our findings are in line with prior literature that identified multicollinearity as a predictor of bias in squared regression structure coefficients but not coefficients of determination, the findings from this study are unique in that the level of predictive power, number of predictors, and sample size were also observed to contribute bias in squared regression structure coefficients. PMID:26217273

  20. Effect of inhibitory feedback on correlated firing of spiking neural network.

    PubMed

    Xie, Jinli; Wang, Zhijie

    2013-08-01

    Understanding the properties and mechanisms that generate different forms of correlation is critical for determining their role in cortical processing. Researches on retina, visual cortex, sensory cortex, and computational model have suggested that fast correlation with high temporal precision appears consistent with common input, and correlation on a slow time scale likely involves feedback. Based on feedback spiking neural network model, we investigate the role of inhibitory feedback in shaping correlations on a time scale of 100 ms. Notably, the relationship between the correlation coefficient and inhibitory feedback strength is non-monotonic. Further, computational simulations show how firing rate and oscillatory activity form the basis of the mechanisms underlying this relationship. When the mean firing rate holds unvaried, the correlation coefficient increases monotonically with inhibitory feedback, but the correlation coefficient keeps decreasing when the network has no oscillatory activity. Our findings reveal that two opposing effects of the inhibitory feedback on the firing activity of the network contribute to the non-monotonic relationship between the correlation coefficient and the strength of the inhibitory feedback. The inhibitory feedback affects the correlated firing activity by modulating the intensity and regularity of the spike trains. Finally, the non-monotonic relationship is replicated with varying transmission delay and different spatial network structure, demonstrating the universality of the results.

  1. Enhance-Synergism and Suppression Effects in Multiple Regression

    ERIC Educational Resources Information Center

    Lipovetsky, Stan; Conklin, W. Michael

    2004-01-01

    Relations between pairwise correlations and the coefficient of multiple determination in regression analysis are considered. The conditions for the occurrence of enhance-synergism and suppression effects when multiple determination becomes bigger than the total of squared correlations of the dependent variable with the regressors are discussed. It…

  2. Cross-cultural adaptation and validation of the Turkish version of Oxford hip score.

    PubMed

    Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Hazar, Zeynep; Yüksel, İnci; Atilla, Bülent

    2015-06-01

    The purpose of this study was to translate the Oxford hip score (OHS) into Turkish and to evaluate the psychometric properties by testing the internal consistency, reproducibility, construct validity, and responsiveness in patients with hip osteoarthritis (OA). Oxford hip score was translated and culturally adapted according to the guidelines in the literature. Seventy patients (mean age 61.45 ± 9.29 years) with hip osteoarthritis participated in the study. Patients completed the Turkish Oxford hip score (OHS-TR), the Short-Form 36 (SF-36), and Western Ontario and McMaster Universities Index (WOMAC). Internal consistency was tested using Cronbach's α coefficient. Patients completed OHS-TR questionnaire twice in 7 days for determining the reproducibility. Correlation between the total results of both tests was determined by the Pearson correlation coefficient and intraclass correlation coefficient (ICC). Validity was assessed by calculating the Pearson correlation coefficient between the OHS-TR and WOMAC and SF-36 scores. Floor and ceiling effects were analyzed. The internal consistency was high (Cronbach's α 0.93). The construct validity showed a significant correlation between the OHS-TR and WOMAC and related SF-36 domains (p < 0.001). The ICC's ranged between 0.80 and 0.99. There was no floor or ceiling effect in total OHS-TR score. The OHS-TR questionnaire is valid, reliable, and responsive for the Turkish-speaking patients with hip OA.

  3. Relationship between plethysmographic waveform changes and hemodynamic variables in anesthetized, mechanically ventilated patients undergoing continuous cardiac output monitoring.

    PubMed

    Thiele, Robert H; Colquhoun, Douglas A; Patrie, James; Nie, Sarah H; Huffmyer, Julie L

    2011-12-01

    To assess the relation between photoplethysmographically-derived parameters and invasively-determined hemodynamic variables. After induction of anesthesia and placement of a Swan-Ganz CCOmbo catheter, a Nonin OEM III probe was placed on each patient's earlobe. Photoplethysmographic signals were recorded in conjunction with cardiac output. Photoplethysmographic metrics (amplitude of absorbance waveform, maximal slope of absorbance waveform, area under the curve, and width) were calculated offline and compared with invasively determined hemodynamic variables. Subject-specific associations between each dependent and independent variable pair were summarized on a per-subject basis by the nonparametric Spearman rank correlation coefficient. The bias-corrected accelerated bootstrap resampling procedure of Efron and Tibshirani was used to obtain a 95% confidence interval for the median subject-specific correlation coefficient, and Wilcoxon sign-rank tests were conducted to test the null hypothesis that the median of the subject-specific correlation coefficients were equal to 0. University hospital. Eighteen patients undergoing coronary artery bypass graft surgery. Placement of a Swan-Ganz CCOmbo catheter and a Nonin OEM III pulse oximetry probe. There was a positive, statistically significant correlation between stroke volume and width (median correlation coefficient, 0.29; confidence interval, 0.01-0.46; p = 0.034). The concordance between changes in stroke volume and changes in width was 53%. No other correlations achieved statistical significance. This study was unable to reproduce the results of prior studies. Only stroke volume and photoplethysmographic width were correlated in this study; however, the correlation and concordance (based on analysis of a 4-quadrant plot) were too weak to be clinically useful. Future studies in patients undergoing low-to-moderate risk surgery may result in improved correlations and clinical utility. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. Biostatistics Series Module 6: Correlation and Linear Regression.

    PubMed

    Hazra, Avijit; Gogtay, Nithya

    2016-01-01

    Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient ( r ). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r 2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation ( y = a + bx ), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous.

  5. Biostatistics Series Module 6: Correlation and Linear Regression

    PubMed Central

    Hazra, Avijit; Gogtay, Nithya

    2016-01-01

    Correlation and linear regression are the most commonly used techniques for quantifying the association between two numeric variables. Correlation quantifies the strength of the linear relationship between paired variables, expressing this as a correlation coefficient. If both variables x and y are normally distributed, we calculate Pearson's correlation coefficient (r). If normality assumption is not met for one or both variables in a correlation analysis, a rank correlation coefficient, such as Spearman's rho (ρ) may be calculated. A hypothesis test of correlation tests whether the linear relationship between the two variables holds in the underlying population, in which case it returns a P < 0.05. A 95% confidence interval of the correlation coefficient can also be calculated for an idea of the correlation in the population. The value r2 denotes the proportion of the variability of the dependent variable y that can be attributed to its linear relation with the independent variable x and is called the coefficient of determination. Linear regression is a technique that attempts to link two correlated variables x and y in the form of a mathematical equation (y = a + bx), such that given the value of one variable the other may be predicted. In general, the method of least squares is applied to obtain the equation of the regression line. Correlation and linear regression analysis are based on certain assumptions pertaining to the data sets. If these assumptions are not met, misleading conclusions may be drawn. The first assumption is that of linear relationship between the two variables. A scatter plot is essential before embarking on any correlation-regression analysis to show that this is indeed the case. Outliers or clustering within data sets can distort the correlation coefficient value. Finally, it is vital to remember that though strong correlation can be a pointer toward causation, the two are not synonymous. PMID:27904175

  6. Genetic diversity of popcorn genotypes using molecular analysis.

    PubMed

    Resh, F S; Scapim, C A; Mangolin, C A; Machado, M F P S; do Amaral, A T; Ramos, H C C; Vivas, M

    2015-08-19

    In this study, we analyzed dominant molecular markers to estimate the genetic divergence of 26 popcorn genotypes and evaluate whether using various dissimilarity coefficients with these dominant markers influences the results of cluster analysis. Fifteen random amplification of polymorphic DNA primers produced 157 amplified fragments, of which 65 were monomorphic and 92 were polymorphic. To calculate the genetic distances among the 26 genotypes, the complements of the Jaccard, Dice, and Rogers and Tanimoto similarity coefficients were used. A matrix of Dij values (dissimilarity matrix) was constructed, from which the genetic distances among genotypes were represented in a more simplified manner as a dendrogram generated using the unweighted pair-group method with arithmetic average. Clusters determined by molecular analysis generally did not group material from the same parental origin together. The largest genetic distance was between varieties 17 (UNB-2) and 18 (PA-091). In the identification of genotypes with the smallest genetic distance, the 3 coefficients showed no agreement. The 3 dissimilarity coefficients showed no major differences among their grouping patterns because agreement in determining the genotypes with large, medium, and small genetic distances was high. The largest genetic distances were observed for the Rogers and Tanimoto dissimilarity coefficient (0.74), followed by the Jaccard coefficient (0.65) and the Dice coefficient (0.48). The 3 coefficients showed similar estimations for the cophenetic correlation coefficient. Correlations among the matrices generated using the 3 coefficients were positive and had high magnitudes, reflecting strong agreement among the results obtained using the 3 evaluated dissimilarity coefficients.

  7. Pulmonary Catherization Data Correlate Poorly with Renal Function in Heart Failure.

    PubMed

    Masha, Luke; Stone, James; Stone, Danielle; Zhang, Jun; Sheng, Luo

    2018-04-10

    The mechanisms of renal dysfunction in heart failure are poorly understood. We chose to explore the relationship of cardiac filling pressures and cardiac index (CI) in relation to renal dysfunction in advanced heart failure. To determine the relationship between renal function and cardiac filling pressures using the United Network of Organ Sharing (UNOS) pulmonary artery catherization registry. Patients over the age of 18 years who were listed for single-organ heart transplantation were included. Exclusion criteria included a history of mechanical circulatory support, previous transplantation, any use of renal replacement therapy, prior history of malignancy, and cardiac surgery, amongst others. Correlations between serum creatinine (SCr) and CI, pulmonary capillary wedge pressure (PCWP), pulmonary artery systolic pressure (PASP), and pulmonary artery diastolic pressure (PADP) were assessed by Pearson correlation coefficients and simple linear regression coefficients. Pearson correlation coefficients between SCr and PCWP, PASP, and PADP were near zero with values of 0.1, 0.07, and 0.08, respectively (p < 0.0001). A weak negative correlation coefficient between SCr and CI was found (correlation coefficient, -0.045, p = 0.027). In a subgroup of young patients unlikely to have noncardiac etiologies, no significant correlations between these values were identified. These findings suggest that, as assessed by pulmonary artery catherization, none of the factors - PCWP, PASP, PADP, or CI - play a prominent role in cardiorenal syndromes. © 2018 S. Karger AG, Basel.

  8. Effective screening length and quasiuniversality for the restricted primitive model of an electrolyte solution.

    PubMed

    Janecek, Jirí; Netz, Roland R

    2009-02-21

    Monte Carlo simulations for the restricted primitive model of an electrolyte solution above the critical temperature are performed at a wide range of concentrations and temperatures. Thermodynamic properties such as internal energy, osmotic coefficient, activity coefficient, as well as spatial correlation functions are determined. These observables are used to investigate whether quasiuniversality in terms of an effective screening length exists, similar to the role played by the effective electron mass in solid-state physics. To that end, an effective screening length is extracted from the asymptotic behavior of the Fourier-transformed charge-correlation function and plugged into the Debye-Huckel limiting expressions for various thermodynamic properties. Comparison with numerical results is favorable, suggesting that correlation and other effects not captured on the Debye-Huckel limiting level can be successfully incorporated by a single effective parameter while keeping the functional form of Debye-Huckel expressions. We also compare different methods to determine mean ionic activity coefficient in molecular simulations and check the internal consistency of the numerical data.

  9. Distribution coefficients of rare earth ions in cubic zirconium dioxide

    NASA Astrophysics Data System (ADS)

    Romer, H.; Luther, K.-D.; Assmus, W.

    1994-08-01

    Cubic zirconium dioxide crystals are grown with the skull melting technique. The effective distribution coefficients for Nd(exp 3+), Sm(exp 3+) and Er(sup 3+) as dopants are determined experimentally as a function of the crystal growth velocity. With the Burton-Prim-Slichter theory, the equilibrium distribution coefficients can be calculated. The distribution coefficients of all other trivalent rare earth ions can be estimated by applying the correlation towards the ionic radii.

  10. Thermodiffusion Coefficient Analysis of n-Dodecane /n-Hexane Mixture at Different Mass Fractions and Pressure Conditions

    NASA Astrophysics Data System (ADS)

    Lizarraga, Ion; Bou-Ali, M. Mounir; Santamaría, C.

    2018-03-01

    In this study, the thermodiffusion coefficient of n-dodecane/n-hexane binary mixture at 25 ∘C mean temperature was determined for several pressure conditions and mass fractions. The experimental technique used to determine the thermodiffusion coefficient was the thermograviational column of cylindrical configuration. In turn, thermophysical properties, such as density, thermal expansion, mass expansion and dynamic viscosity up to 10 MPa were also determined. The results obtained in this work showed a linear relation between the thermophysical properties and the pressure. Thermodiffusion coefficient values confirm a linear effect when the pressure increases. Additionally, a new correlation based on the thermodiffusion coefficient for n C12/n C6 binary mixture at 25 ∘C temperature for any mass fraction and pressures, which reproduces the data within the experimental error, was proposed.

  11. Comparison of a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography.

    PubMed

    Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W

    1988-08-01

    The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.

  12. Instrument validation process: a case study using the Paediatric Pain Knowledge and Attitudes Questionnaire.

    PubMed

    Peirce, Deborah; Brown, Janie; Corkish, Victoria; Lane, Marguerite; Wilson, Sally

    2016-06-01

    To compare two methods of calculating interrater agreement while determining content validity of the Paediatric Pain Knowledge and Attitudes Questionnaire for use with Australian nurses. Paediatric pain assessment and management documentation was found to be suboptimal revealing a need to assess paediatric nurses' knowledge and attitude to pain. The Paediatric Pain Knowledge and Attitudes Questionnaire was selected as it had been reported as valid and reliable in the United Kingdom with student nurses. The questionnaire required content validity determination prior to use in the Australian context. A two phase process of expert review. Ten paediatric nurses completed a relevancy rating of all 68 questionnaire items. In phase two, five pain experts reviewed the items of the questionnaire that scored an unacceptable item level content validity. Item and scale level content validity indices and intraclass correlation coefficients were calculated. In phase one, 31 items received an item level content validity index <0·78 and the scale level content validity index average was 0·80 which were below levels required for acceptable validity. The intraclass correlation coefficient was 0·47. In phase two, 10 items were amended and four items deleted. The revised questionnaire provided a scale level content validity index average >0·90 and an intraclass correlation coefficient of 0·94 demonstrating excellent agreement between raters therefore acceptable content validity. Equivalent outcomes were achieved using the content validity index and the intraclass correlation coefficient. To assess content validity the content validity index has the advantage of providing an item level score and is a simple calculation. The intraclass correlation coefficient requires statistical knowledge, or support, and has the advantage of accounting for the possibility of chance agreement. © 2016 John Wiley & Sons Ltd.

  13. Correlation of laboratory and production freeze drying cycles.

    PubMed

    Kuu, Wei Y; Hardwick, Lisa M; Akers, Michael J

    2005-09-30

    The purpose of this study was to develop the correlation of cycle parameters between a laboratory and a production freeze-dryer. With the established correlation, key cycle parameters obtained using a laboratory dryer may be converted to those for a production dryer with minimal experimental efforts. In order to develop the correlation, it was important to consider the contributions from the following freeze-drying components: (1) the dryer, (2) the vial, and (3) the formulation. The critical parameters for the dryer are the shelf heat transfer coefficient and shelf surface radiation emissivity. The critical parameters for the vial are the vial bottom heat transfer coefficients (the contact parameter Kcs and separation distance lv), and vial top heat transfer coefficient. The critical parameter of the formulation is the dry layer mass transfer coefficient. The above heat and mass transfer coefficients were determined by freeze-drying experiments in conjunction with mathematical modeling. With the obtained heat and mass transfer coefficients, the maximum product temperature, Tbmax, during primary drying was simulated using a primary drying subroutine as a function of the shelf temperature and chamber pressure. The required shelf temperature and chamber pressure, in order to perform a successful cycle run without product collapse, were then simulated based on the resulting values of Tbmax. The established correlation approach was demonstrated by the primary drying of the model formulation 5% mannitol solution. The cycle runs were performed using a LyoStar dryer as the laboratory dryer and a BOC Edwards dryer as the production dryer. The determined normalized dried layer mass transfer resistance for 5% mannitol is expressed as RpN=0.7313+17.19l, where l is the receding dry layer thickness. After demonstrating the correlation approach using the model formulation 5% mannitol, a practical comparison study was performed for the actual product, the lactate dehydrogenase (LDH) formulation. The determined normalized dried layer mass transfer resistance for the LDH formulation is expressed as RpN=4.344+10.85l. The operational templates Tbmax and primary drying time were also generated by simulation. The cycle run for the LDH formulation using the Edwards production dryer verified that the cycle developed in a laboratory freeze-dryer was transferable at the production scale.

  14. Anisotropic diffusion of fluorescently labeled ATP in rat cardiomyocytes determined by raster image correlation spectroscopy

    PubMed Central

    Vendelin, Marko; Birkedal, Rikke

    2008-01-01

    A series of experimental data points to the existence of profound diffusion restrictions of ADP/ATP in rat cardiomyocytes. This assumption is required to explain the measurements of kinetics of respiration, sarcoplasmic reticulum loading with calcium, and kinetics of ATP-sensitive potassium channels. To be able to analyze and estimate the role of intracellular diffusion restrictions on bioenergetics, the intracellular diffusion coefficients of metabolites have to be determined. The aim of this work was to develop a practical method for determining diffusion coefficients in anisotropic medium and to estimate the overall diffusion coefficients of fluorescently labeled ATP in rat cardiomyocytes. For that, we have extended raster image correlation spectroscopy (RICS) protocols to be able to discriminate the anisotropy in the diffusion coefficient tensor. Using this extended protocol, we estimated diffusion coefficients of ATP labeled with the fluorescent conjugate Alexa Fluor 647 (Alexa-ATP). In the analysis, we assumed that the diffusion tensor can be described by two values: diffusion coefficient along the myofibril and that across it. The average diffusion coefficients found for Alexa-ATP were as follows: 83 ± 14 μm2/s in the longitudinal and 52 ± 16 μm2/s in the transverse directions (n = 8, mean ± SD). Those values are ∼2 (longitudinal) and ∼3.5 (transverse) times smaller than the diffusion coefficient value estimated for the surrounding solution. Such uneven reduction of average diffusion coefficient leads to anisotropic diffusion in rat cardiomyocytes. Although the source for such anisotropy is uncertain, we speculate that it may be induced by the ordered pattern of intracellular structures in rat cardiomyocytes. PMID:18815224

  15. Fungible Correlation Matrices: A Method for Generating Nonsingular, Singular, and Improper Correlation Matrices for Monte Carlo Research.

    PubMed

    Waller, Niels G

    2016-01-01

    For a fixed set of standardized regression coefficients and a fixed coefficient of determination (R-squared), an infinite number of predictor correlation matrices will satisfy the implied quadratic form. I call such matrices fungible correlation matrices. In this article, I describe an algorithm for generating positive definite (PD), positive semidefinite (PSD), or indefinite (ID) fungible correlation matrices that have a random or fixed smallest eigenvalue. The underlying equations of this algorithm are reviewed from both algebraic and geometric perspectives. Two simulation studies illustrate that fungible correlation matrices can be profitably used in Monte Carlo research. The first study uses PD fungible correlation matrices to compare penalized regression algorithms. The second study uses ID fungible correlation matrices to compare matrix-smoothing algorithms. R code for generating fungible correlation matrices is presented in the supplemental materials.

  16. Correlation between developmental quotients (DASII) and social quotient (Malin's VSMS) in Indian children aged 6 months to 2 years.

    PubMed

    Bhave, Anupama; Bhargava, Roli; Kumar, Rashmi

    2011-03-01

    To determine correlation between developmental quotients (DQ) (DASII) and social quotients (SQ) (Malin's Vineland Social Maturity Scale (VSMS)). Malin's VSMS and DASII were done in 135 children aged 6 months to 2 years. SQ and DQ motor and mental were correlated using Pearson's correlation coefficient (r). Mean SQ and DQ and age equivalent scores were compared. Correlation coefficients between SQ and DQ (mental and motor were 0.849 and 0.791, respectively. Social age correlated highly with mental age (r = 0.906). Mean SQ was higher than mean DQa. SQ tends to be higher than DQ and correlates best with DQ mental. © 2010 The Authors. Journal of Paediatrics and Child Health © 2010 Paediatrics and Child Health Division (Royal Australasian College of Physicians).

  17. A Thick-film Sensor as a Novel Device for Determination of Polyphenols and Their Antioxidant Capacity in White Wine

    PubMed Central

    Photinon, Kanokorn; Chalermchart, Yongyuth; Khanongnuch, Chartchai; Wang, Shih-Han; Liu, Chung-Chiun

    2010-01-01

    A thick-film electrochemical sensor with an iridium-carbon working electrode was used for determining polyphenols and their antioxidant capacity in white wine. Caffeic acid was used as a model species because it has the ability to produce the highest oxidation current. The correlation coefficient of 0.9975 was obtained between sensor response and caffeic acid content. The total phenolic content (TPC) and scavenging activity on 1,1-diphenyl-2-pycrylhydrazyl (DPPH·) radical were also found to be strongly correlated with the concentration of caffeic acid, with a correlation coefficient of 0.9823 and 0.9958, respectively. The sensor prototype was proven to be a simple, efficient and cost effective device to evaluate the antioxidant capacity of substances. PMID:22294893

  18. A thick-film sensor as a novel device for determination of polyphenols and their antioxidant capacity in white wine.

    PubMed

    Photinon, Kanokorn; Chalermchart, Yongyuth; Khanongnuch, Chartchai; Wang, Shih-Han; Liu, Chung-Chiun

    2010-01-01

    A thick-film electrochemical sensor with an iridium-carbon working electrode was used for determining polyphenols and their antioxidant capacity in white wine. Caffeic acid was used as a model species because it has the ability to produce the highest oxidation current. The correlation coefficient of 0.9975 was obtained between sensor response and caffeic acid content. The total phenolic content (TPC) and scavenging activity on 1,1-diphenyl-2-pycrylhydrazyl (DPPH·) radical were also found to be strongly correlated with the concentration of caffeic acid, with a correlation coefficient of 0.9823 and 0.9958, respectively. The sensor prototype was proven to be a simple, efficient and cost effective device to evaluate the antioxidant capacity of substances.

  19. Turbulence in a gaseous hydrogen-liquid oxygen rocket combustion chamber

    NASA Technical Reports Server (NTRS)

    Lebas, J.; Tou, P.; Ohara, J.

    1975-01-01

    The intensity of turbulence and the Lagrangian correlation coefficient for a LOX-GH2 rocket combustion chamber was determined from experimental measurements of tracer gas diffusion. A combination of Taylor's turbulent diffusion theory and a numerical method for solving the conservation equations of fluid mechanics was used to calculate these quantities. Taylor's theory was extended to consider the inhomogeneity of the turbulence field in the axial direction of the combustion chamber, and an exponential function was used to represent the Lagrangian correlation coefficient. The results indicate that the value of the intensity of turbulence reaches a maximum of 14% at a location about 7" downstream from the injector. The Lagrangian correlation coefficient associated with this value is given by the above exponential expression where alpha = 10,000/sec.

  20. Evaluation of the pulse-contour method of determining stroke volume in man.

    NASA Technical Reports Server (NTRS)

    Alderman, E. L.; Branzi, A.; Sanders, W.; Brown, B. W.; Harrison, D. C.

    1972-01-01

    The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.

  1. Evaluating the validity and reliability of the V-scale instrument (Turkish version) used to determine nurses' attitudes towards vital sign monitoring.

    PubMed

    Ertuğ, Nurcan

    2018-06-01

    The aim of this study was to determine the validity and reliability of the Turkish version of the V-scale, which measures nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. This validity and reliability study was conducted at a tertiary hospital in Ankara, Turkey, in 2016. A total of 169 ward nurses participated in the study. Exploratory factor analysis, Cronbach's alpha coefficient, and the intraclass correlation coefficient were used to determine the validity and reliability of the scale. A 5-factor, 16-item scale explained 60.823% of the total variance according to the validity analysis. Our version matched the original scale in terms of the number of items and factor structure. Cronbach's alpha coefficient of the Turkish version of the V-scale was 0.764. The test-retest reliability results were 0.855 for the overall intraclass correlation coefficient, and the t-test result was P > 0.05. The V-scale is a reliable and valid instrument to measure Turkish nurses' attitudes towards vital signs monitoring in the detection of clinical deterioration. © 2018 John Wiley & Sons Australia, Ltd.

  2. Analytical determination of propeller performance degradation due to ice accretion

    NASA Technical Reports Server (NTRS)

    Miller, T. L.

    1986-01-01

    A computer code has been developed which is capable of computing propeller performance for clean, glaze, or rime iced propeller configurations, thereby providing a mechanism for determining the degree of performance degradation which results from a given icing encounter. The inviscid, incompressible flow field at each specified propeller radial location is first computed using the Theodorsen transformation method of conformal mapping. A droplet trajectory computation then calculates droplet impingement points and airfoil collection efficiency for each radial location, at which point several user-selectable empirical correlations are available for determining the aerodynamic penalities which arise due to the ice accretion. Propeller performance is finally computed using strip analysis for either the clean or iced propeller. In the iced mode, the differential thrust and torque coefficient equations are modified by the drag and lift coefficient increments due to ice to obtain the appropriate iced values. Comparison with available experimental propeller icing data shows good agreement in several cases. The code's capability to properly predict iced thrust coefficient, power coefficient, and propeller efficiency is shown to be dependent on the choice of empirical correlation employed as well as proper specification of radial icing extent.

  3. Determinations of cloud liquid water in the tropics from the SSM/I

    NASA Technical Reports Server (NTRS)

    Alishouse, John C.; Swift, Calvin; Ruf, Christopher; Snyder, Sheila; Vongsathorn, Jennifer

    1989-01-01

    Upward-looking microwave radiometric observations were used to validate the SSM/I determinations, and also as a basis for the determination of new coefficients. Due to insufficiency of the initial four channel algorithm for cloud liquid water, the improved algorithm was derived from the CORRAD (the University of Massachusetts autocorrelation radiometer) measurements of cloud liquid water and the matching SSM/I brightness temperatures using the standard linear regression. The correlation coefficients for the possible four channel combinations, and subsequently the best and the worst combinations were determined.

  4. Long-term behaviour and cross-correlation water quality analysis of the River Elbe, Germany.

    PubMed

    Lehmann, A; Rode, M

    2001-06-01

    This study analyses weekly data samples from the river Elbe at Magdeburg between 1984 and 1996 to investigate the changes in metabolism and water quality in the river Elbe since the German reunification in 1990. Modelling water quality variables by autoregressive component models and ARIMA models reveals the improvement of water quality due to the reduction of waste water emissions since 1990. The models are used to determine the long-term and seasonal behaviour of important water quality variables. Organic and heavy metal pollution parameters showed a significant decrease since 1990, however, no significant change of chlorophyll-a as a measure for primary production could be found. A new procedure for testing the significance of a sample correlation coefficient is discussed, which is able to detect spurious sample correlation coefficients without making use of time-consuming prewhitening. The cross-correlation analysis is applied to hydrophysical, biological, and chemical water quality variables of the river Elbe since 1984. Special emphasis is laid on the detection of spurious sample correlation coefficients.

  5. Determination of facial symmetry in unilateral cleft lip and palate patients from three-dimensional data: technical report and assessment of measurement errors.

    PubMed

    Nkenke, Emeka; Lehner, Bernhard; Kramer, Manuel; Haeusler, Gerd; Benz, Stefanie; Schuster, Maria; Neukam, Friedrich W; Vairaktaris, Eleftherios G; Wurm, Jochen

    2006-03-01

    To assess measurement errors of a novel technique for the three-dimensional determination of the degree of facial symmetry in patients suffering from unilateral cleft lip and palate malformations. Technical report, reliability study. Cleft Lip and Palate Center of the University of Erlangen-Nuremberg, Erlangen, Germany. The three-dimensional facial surface data of five 10-year-old unilateral cleft lip and palate patients were subjected to the analysis. Distances, angles, surface areas, and volumes were assessed twice. Calculations were made for method error, intraclass correlation coefficient, and repeatability of the measurements of distances, angles, surface areas, and volumes. The method errors were less than 1 mm for distances and less than 1.5 degrees for angles. The intraclass correlation coefficients showed values greater than .90 for all parameters. The repeatability values were comparable for cleft and noncleft sides. The small method errors, high intraclass correlation coefficients, and comparable repeatability values for cleft and noncleft sides reveal that the new technique is appropriate for clinical use.

  6. Physiological Background of Differences in Quantitative Diffusion-Weighted Magnetic Resonance Imaging Between Acute Malignant and Benign Vertebral Body Fractures: Correlation of Apparent Diffusion Coefficient With Quantitative Perfusion Magnetic Resonance Imaging Using the 2-Compartment Exchange Model.

    PubMed

    Geith, Tobias; Biffar, Andreas; Schmidt, Gerwin; Sourbron, Steven; Dietrich, Olaf; Reiser, Maximilian; Baur-Melnyk, Andrea

    2015-01-01

    To test the hypothesis that apparent diffusion coefficient (ADC) in vertebral bone marrow of benign and malignant fractures is related to the volume of the interstitial space, determined with dynamic contrast-enhanced (DCE) magnetic resonance imaging. Patients with acute benign (n = 24) and malignant (n = 19) vertebral body fractures were examined at 1.5 T. A diffusion-weighted single-shot turbo-spin-echo sequence (b = 100 to 600 s/mm) and DCE turbo-FLASH sequence were evaluated. Regions of interest were manually selected for each fracture. Apparent diffusion coefficient was determined with a monoexponential decay model. The DCE magnetic resonance imaging concentration-time curves were analyzed using a 2-compartment tracer-kinetic model. Apparent diffusion coefficient showed a significant positive correlation with interstitial volume in the whole study population (Pearson r = 0.66, P < 0.001), as well as in the malignant (Pearson r = 0.64, P = 0.004) and benign (Pearson r = 0.52, P = 0.01) subgroup. A significant correlation between ADC and the permeability-surface area product could be observed when analyzing the whole study population (Spearman rs = 0.40, P = 0.008), but not when separately examining the subgroups. Plasma flow showed a significant correlation with ADC in benign fractures (Pearson r = 0.23, P = 0.03). Plasma volume did not show significant correlations with ADC. The results support the hypothesis that the ADC of a lesion is inversely correlated to its cellularity. This explains previous observations that ADC is reduced in more malignant lesions.

  7. [Spectral reflectance characteristics and modeling of typical Takyr Solonetzs water content].

    PubMed

    Zhang, Jun-hua; Jia, Ke-li

    2015-03-01

    Based on the analysis of the spectral reflectance of the typical Takyr Solonetzs soil in Ningxia, the relationship of soil water content and spectral reflectance was determined, and a quantitative model for the prediction of soil water content was constructed. The results showed that soil spectral reflectance decreased with the increasing soil water content when it was below the water holding capacity but increased with the increasing soil water content when it was higher than the water holding capacity. Soil water content presented significantly negative correlation with original reflectance (r), smooth reflectance (R), logarithm of reflectance (IgR), and positive correlation with the reciprocal of R and logarithm of reciprocal [lg (1/R)]. The correlation coefficient of soil water content and R in the whole wavelength was 0.0013, 0.0397 higher than r and lgR, respectively. Average correlation coefficient of soil water content with 1/R and [lg (1/R)] at the wavelength of 950-1000 nm was 0.2350 higher than that of 400-950 nm. The relationships of soil water content with the first derivate differential (R') , the first derivate differential of logarithm (lgR)' and the first derivate differential of logarithm of reciprocal [lg(1/R)]' were unstable. Base on the coefficients of r, lg(1/R), R' and (lgR)', different regression models were established to predict soil water content, and the coefficients of determination were 0.7610, 0.8184, 0.8524 and 0.8255, respectively. The determination coefficient for power function model of R'. reached 0.9447, while the fitting degree between the predicted value based on this model and on-site measured value was 0.8279. The model of R' had the highest fitted accuracy, while that of r had the lowest one. The results could provide a scientific basis for soil water content prediction and field irrigation in the Takyr Solonetzs region.

  8. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study.

    PubMed

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent.

  9. Optimization of selective breeding through analysis of morphological traits in Chinese sea bass (Lateolabrax maculatus).

    PubMed

    Wang, W; Ma, C Y; Chen, W; Ma, H Y; Zhang, H; Meng, Y Y; Ni, Y; Ma, L B

    2016-08-19

    Determining correlations between certain traits of economic importance constitutes an essential component of selective activities. In this study, our aim was to provide effective indicators for breeding programs of Lateolabrax maculatus, an important aquaculture species in China. We analyzed correlations between 20 morphometric traits and body weight, using correlation and path analyses. The results indicated that the correlations among all 21 traits were highly significant, with the highest correlation coefficient identified between total length and body weight. The path analysis indicated that total length (X 1 ), body width (X 5 ), distance from first dorsal fin origin to anal fin origin (X 10 ), snout length (X 16 ), eye diameter (X 17 ), eye cross (X 18 ), and slanting distance from snout tip to first dorsal fin origin (X 19 ) significantly affected body weight (Y) directly. The following multiple-regression equation was obtained using stepwise multiple-regression analysis: Y = -472.108 + 1.065X 1 + 7.728X 5 + 1.973X 10 - 7.024X 16 - 4.400X 17 - 3.338X 18 + 2.138X 19 , with an adjusted multiple-correlation coefficient of 0.947. Body width had the largest determinant coefficient, as well as the highest positive direct correlation with body weight. At the same time, high indirect effects with six other morphometric traits on L. maculatus body weight, through body width, were identified. Hence, body width could be a key factor that efficiently indicates significant effects on body weight in L. maculatus.

  10. Growth and Development of Dentofacial Complex influenced by Genetic and Environmental Factors using Monozygotic Twins.

    PubMed

    Manjusha, K K; Jyothindrakumar, K; Nishad, A; Manoj, K Madhav

    2017-09-01

    The purpose of this study was to determine the possible effects of genetic and environmental factors on dentofacial complex using monozygotic twins. The study sample was made of 21 pairs of monozygotic twins (14 female pairs and seven male pairs) between 10 and 25 years. Pretreatment lateral cephalo-grams were used which were traced and digitized, and various landmarks to determine the anteroposterior and vertical proportions were marked. Samples were divided into two groups. The correlation between groups was found by calculating Pearson's product moment correlation coefficients. The range of the correlation coefficient was from 0.705 to 0.952. Gonial angle showed the highest correlation coefficient (0.952), while saddle angle showed the lowest correlation coefficient (0.705). The growth and development of craniofacial complex is under mutifactorial control. However, genetic influences do tend to play a dominant role. By studying identical twins, we can study about the interaction of the environment with the genes and how it affects the growth and development of the body in general and dentofacial complex in particular. By utilizing twin studies, we can identify whether a particular trait, disease, or disorder is influenced more strongly by genetics or by the environment. Success of orthodontic treatment depends on a proper diagnosis of the problem including its etiological factors. Genetic studies let the orthodontists to understand the effects of genetic and environmental factors in the growth and development of dentofacial complex better and allows to prevent or treat malocclusions and skeletal anomalies in better ways.

  11. Oxford Knee Score: cross-cultural adaptation and validation of the Turkish version in patients with osteoarthritis of the knee.

    PubMed

    Tuğay, Baki Umut; Tuğay, Nazan; Güney, Hande; Kınıklı, Gizem İrem; Yüksel, İnci; Atilla, Bülent

    2016-01-01

    The Oxford Knee Score (OKS) is a valid, short, self-administered, and site- specific outcome measure specifically developed for patients with knee arthroplasty. This study aimed to cross-culturally adapt and validate the OKS to be used in Turkish-speaking patients with osteoarthritis of the knee. The OKS was translated and culturally adapted according to the guidelines in the literature. Ninety-one patients (mean age: 55.89±7.85 years) with knee osteoarthritis participated in the study. Patients completed the Turkish version of the Oxford Knee Score (OKS-TR), Short-Form 36 Health Survey (SF-36), and Western Ontario and McMaster Universities Index (WOMAC) questionnaires. Internal consistency was tested using Cronbach's α coefficient. Patients completed the OKS-TR questionnaire twice in 7 days to determine the reproducibility. Correlation between the total results of both tests was determined by Spearman's correlation coefficient and intraclass correlation coefficients (ICC). Validity was assessed by calculating Spearman's correlation coefficient between the OKS, WOMAC, and SF-36 scores. Floor and ceiling effects were analyzed. Internal consistency was high (Cronbach's α: 0.90). The reproducibility tested by 2 different methods showed no significant difference (p>0.05). The construct validity analyses showed a significant correlation between the OKS and the other scores (p<0.05). There was no floor or ceiling effect in total OKS score. The OKS-TR is a reliable and valid measure for the self-assessment of pain and function in Turkish-speaking patients with osteoarthritis of the knee.

  12. Correlation of skeletal maturation stages determined by cervical vertebrae and hand-wrist evaluations.

    PubMed

    Flores-Mir, Carlos; Burgess, Corr A; Champney, Mitchell; Jensen, Robert J; Pitcher, Micheal R; Major, Paul W

    2006-01-01

    The aim of this study was to assess the correlation between the Fishman maturation prediction method (FMP) and the cervical vertebral maturation (CVM) method for skeletal maturation stage determination. Hand-wrist and lateral cephalograms from 79 subjects (52 females and 27 males) were used. Hand-wrist radiographs were analyzed using the FMP to determine skeletal maturation level (advanced, average, or delayed) and stage (relative position of the individual in the pubertal growth curve). Cervical vertebrae (C2, C3, and C4) outlines obtained from lateral cephalograms were analyzed using the CVM to determine skeletal maturation stage. Intraexaminer reliability (Intraclass correlation coefficient [ICC]) for both methods was calculated from 10 triplicate hand-wrist and lateral cephalograms from the same patients. An ICC coefficient of 0.985 for FMP and an ICC of 0.889 for CVM were obtained. A Spearman correlation value of 0.72 (P < .001) was found between the skeletal maturation stages of both methods. When the sample was subgrouped according to skeletal maturation level, the following correlation values were found: for early mature adolescents 0.73, for average mature adolescents 0.70, and for late mature adolescents 0.87. All these correlation values were statistically different from zero (P < .024). Correlation values between both skeletal maturation methods were moderately high. This may be high enough to use either of the methods indistinctively for research purposes but not for the assessment of individual patients. Skeletal level influences the correlation values and, therefore, it should be considered whenever possible.

  13. Comparison of aerodynamic coefficients obtained from theoretical calculations wind tunnel tests and flight tests data reduction for the alpha jet aircraft

    NASA Technical Reports Server (NTRS)

    Guiot, R.; Wunnenberg, H.

    1980-01-01

    The methods by which aerodynamic coefficients are determined and discussed. These include: calculations, wind tunnel experiments and experiments in flight for various prototypes of the Alpha Jet. A comparison of obtained results shows good correlation between expectations and in-flight test results.

  14. Behavior of R-Square for Pooled Data Sets.

    ERIC Educational Resources Information Center

    Adams, Arthur J.; Shiffler, Ronald E.

    1989-01-01

    New methods of analysis--equations and graphs for iso-r(sup 2) contours--were introduced and used to illustrate location effects for pooled data sets. The "r(sup 2)" is the coefficient of determination. Results are used to highlight imprecise statements in the literature about the behavior of the correlation coefficient for pooled data…

  15. The Spaeth/Richman contrast sensitivity test (SPARCS): design, reproducibility and ability to identify patients with glaucoma.

    PubMed

    Richman, Jesse; Zangalli, Camila; Lu, Lan; Wizov, Sheryl S; Spaeth, Eric; Spaeth, George L

    2015-01-01

    (1) To determine the ability of a novel, internet-based contrast sensitivity test titled the Spaeth/Richman Contrast Sensitivity Test (SPARCS) to identify patients with glaucoma. (2) To determine the test-retest reliability of SPARCS. A prospective, cross-sectional study of patients with glaucoma and controls was performed. Subjects were assessed by SPARCS and the Pelli-Robson chart. Reliability of each test was assessed by the intraclass correlation coefficient and the coefficient of repeatability. Sensitivity and specificity for identifying glaucoma was also evaluated. The intraclass correlation coefficient for SPARCS was 0.97 and 0.98 for Pelli-Robson. The coefficient of repeatability for SPARCS was ±6.7% and ±6.4% for Pelli-Robson. SPARCS identified patients with glaucoma with 79% sensitivity and 93% specificity. SPARCS has high test-retest reliability. It is easily accessible via the internet and identifies patients with glaucoma well. NCT01300949. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  16. Clustering stocks using partial correlation coefficients

    NASA Astrophysics Data System (ADS)

    Jung, Sean S.; Chang, Woojin

    2016-11-01

    A partial correlation analysis is performed on the Korean stock market (KOSPI). The difference between Pearson correlation and the partial correlation is analyzed and it is found that when conditioned on the market return, Pearson correlation coefficients are generally greater than those of the partial correlation, which implies that the market return tends to drive up the correlation between stock returns. A clustering analysis is then performed to study the market structure given by the partial correlation analysis and the members of the clusters are compared with the Global Industry Classification Standard (GICS). The initial hypothesis is that the firms in the same GICS sector are clustered together since they are in a similar business and environment. However, the result is inconsistent with the hypothesis and most clusters are a mix of multiple sectors suggesting that the traditional approach of using sectors to determine the proximity between stocks may not be sufficient enough to diversify a portfolio.

  17. Five radiographic methods for assessing skeletal maturity in a Spanish population: is there a correlation?

    PubMed

    Camacho-Basallo, Paula; Yáñez-Vico, Rosa-María; Solano-Reina, Enrique; Iglesias-Linares, Alejandro

    2017-03-01

    The need for accurate techniques of estimating age has sharply increased in line with the rise in illegal migration and the political, economic and socio-demographic problems that this poses in developed countries today. The methods routinely employed for determining chronological age are mainly based on determining skeletal maturation using radiological techniques. The objective of this study was to correlate five different methods for assessing skeletal maturation. 606 radiographs of growing patients were analyzed, and each patient was classified according to two cervical vertebral-based methods, two hand-wrist-based methods and one tooth-based method. Spearman's rank-order correlation coefficient was applied to assess the relationship between chronological age and the five methods of assessing maturation, as well as correlations between the five methods (p < 0.05). Spearman's rank correlation coefficients for chronological age and cervical vertebral maturation stage using both methods were 0.656/0.693 (p < 0.001), respectively, for males. For females, the correlation was stronger for both methods. The correlation coefficients for chronological age against the two hand-wrist assessment methods were statistically significant only for Fishman's method, 0.722 (p < 0.001) and 0.839 (p < 0.001), respectively for males and females. The cervical vertebral, hand-wrist and dental maturation methods of assessment were all found to correlate strongly with each other, irrespective of gender, except for Grave and Brown's method. The results found the strongest correlation between the second molars and females, and the second premolar and males. This study sheds light on and correlates with the five radiographic methods most commonly used for assessing skeletal maturation in a Spanish population in southern Europe.

  18. Effective gaseous diffusion coefficients of select ultra-fine, super-fine and medium grain nuclear graphite

    DOE PAGES

    Kane, Joshua J.; Matthews, Austin C.; Orme, Christopher J.; ...

    2018-05-05

    Understanding “Where?” and “How much?” oxidation has occurred in a nuclear graphite component is critical to predicting any deleterious effects to physical, mechanical, and thermal properties. A key factor in answering these questions is characterizing the effective mass transport rates of gas species in nuclear graphites. Effective gas diffusion coefficients were determined for twenty-six graphite specimens spanning six modern grades of nuclear graphite. A correlation was established for the majority of grades examined allowing a reasonable estimate of the effective diffusion coefficient to be determined purely from an estimate of total porosity. The importance of Knudsen diffusion to the measuredmore » diffusion coefficients is also shown for modern grades. Furthermore, Knudsen diffusion has not historically been considered to contribute to measured diffusion coefficients of nuclear graphite.« less

  19. Effective gaseous diffusion coefficients of select ultra-fine, super-fine and medium grain nuclear graphite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kane, Joshua J.; Matthews, Austin C.; Orme, Christopher J.

    Understanding “Where?” and “How much?” oxidation has occurred in a nuclear graphite component is critical to predicting any deleterious effects to physical, mechanical, and thermal properties. A key factor in answering these questions is characterizing the effective mass transport rates of gas species in nuclear graphites. Effective gas diffusion coefficients were determined for twenty-six graphite specimens spanning six modern grades of nuclear graphite. A correlation was established for the majority of grades examined allowing a reasonable estimate of the effective diffusion coefficient to be determined purely from an estimate of total porosity. The importance of Knudsen diffusion to the measuredmore » diffusion coefficients is also shown for modern grades. Furthermore, Knudsen diffusion has not historically been considered to contribute to measured diffusion coefficients of nuclear graphite.« less

  20. Chronologic age and skeletal maturation of the cervical vertebrae and hand-wrist: is there a relationship?

    PubMed

    Uysal, Tancan; Ramoglu, Sabri Ilhan; Basciftci, Faruk Ayhan; Sari, Zafer

    2006-11-01

    The aims of this study were (1) to investigate the relationship between chronologic age and maturation of cervical vertebrae, (2) to identify the relationship between chronologic age and maturation stage evaluated by hand-wrist radiographs, and (3) to determine whether the maturation of cervical vertebrae correlates with maturation indicated by hand-wrist radiographs in a Turkish population. The samples were derived from lateral cephalometric and hand-wrist radiographs of 503 subjects (213 male, 290 female; ages, 5.3-24.1 years). Cervical vertebral development was evaluated by the method of Hassel and Farman. Skeletal maturation of each hand-wrist radiograph was determined according to the method described by Björk and Grave, and Brown's system. The Spearman rank-order correlation coefficients were estimated separately for males and females to measure the relationships among chronologic age, cervical vertebral maturation, and the skeletal maturation measured at the hand-wrist. The Spearman correlation coefficients were 0.72 (P <.001) between chronologic age and cervical vertebrae skeletal maturation, and 0.79 (P < .001) between chronologic age and maturation via hand-wrist radiographs. The correlation coefficient between hand-wrist and cervical-vertebrae maturation was 0.86 (P <.001). The cervical-vertebrae maturation stages are clinically useful maturity indicators of the pubertal growth period Turkish subjects.

  1. Correlation analysis of a ground-water level monitoring network, Miami-Dade County, Florida

    USGS Publications Warehouse

    Prinos, Scott T.

    2005-01-01

    The U.S. Geological Survey cooperative ground-water monitoring program in Miami-Dade County, Florida, expanded from 4 to 98 continuously recording water-level monitoring wells during the 1939-2001 period. Network design was based on area specific assessments; however, no countywide statistical assessments of network coverage had been performed for the purpose of assessing network redundancy. To aid in the assessment of network redundancy, correlation analyses were performed using S-PLUS 2000 statistical analysis software for daily maximum water-level data from 98 monitoring wells for the November 1, 1973, to October 31, 2000 period. Because of the complexities of the hydrologic, water-supply, and water-management systems in Miami-Dade County and the changes that have occurred to these systems through time, spatial and temporal variations in the degree of correlation had to be considered. To assess temporal variation in correlation, water-level data from each well were subdivided by year and by wet and dry seasons. For each well, year, and season, correlation analyses were performed on the data from those wells that had available data. For selected wells, the resulting correlation coefficients from each year and season were plotted with respect to time. To assess spatial variation in correlation, the coefficients determined from the correlation analysis were averaged. These average wet- and dry-season correlation coefficients were plotted spatially using geographic information system software. Wells with water-level data that correlated with a coefficient of 0.95 or greater were almost always located in relatively close proximity to each other. Five areas were identified where the water-level data from wells within the area remained correlated with that of other wells in the area during the wet and dry seasons. These areas are located in or near the C-1 and C-102 basins (2 wells), in or near the C-6 and C-7 basins (2 wells), near the Florida Keys Aqueduct Authority Well Field (2 wells), near the Hialeah-Miami Springs Well Field (6 wells), and near the West Well Field (21 wells). Data from the remaining 65 wells (most of the wells in the network) generally were not correlated with those of other wells during both the wet and dry seasons with an average coefficient of 0.95 or greater for the comparison. Because many of the wells near the West Well Field and some near the Hialeah-Miami Springs Well Field had not been in operation for very long (most having been installed in 1994), the averaged correlation coefficients for these wells were often determined using only a few seasons of data. For the few instances where water-level data were found to be well correlated on average for a lengthy period of record, short-term declines in correlation were often identified. In general, it would be beneficial to compare data for longer periods of record than currently available.

  2. Drag Coefficient Estimation in Orbit Determination

    NASA Astrophysics Data System (ADS)

    McLaughlin, Craig A.; Manee, Steve; Lichtenberg, Travis

    2011-07-01

    Drag modeling is the greatest uncertainty in the dynamics of low Earth satellite orbits where ballistic coefficient and density errors dominate drag errors. This paper examines fitted drag coefficients found as part of a precision orbit determination process for Stella, Starlette, and the GEOSAT Follow-On satellites from 2000 to 2005. The drag coefficients for the spherical Stella and Starlette satellites are assumed to be highly correlated with density model error. The results using MSIS-86, NRLMSISE-00, and NRLMSISE-00 with dynamic calibration of the atmosphere (DCA) density corrections are compared. The DCA corrections were formulated for altitudes of 200-600 km and are found to be inappropriate when applied at 800 km. The yearly mean fitted drag coefficients are calculated for each satellite for each year studied. The yearly mean drag coefficients are higher for Starlette than Stella, where Starlette is at a higher altitude. The yearly mean fitted drag coefficients for all three satellites decrease as solar activity decreases after solar maximum.

  3. Prediction of random-regression coefficient for daily milk yield after 305 days in milk by using the regression-coefficient estimates from the first 305 days.

    PubMed

    Yamazaki, Takeshi; Takeda, Hisato; Hagiya, Koichi; Yamaguchi, Satoshi; Sasaki, Osamu

    2018-03-13

    Because lactation periods in dairy cows lengthen with increasing total milk production, it is important to predict individual productivities after 305 days in milk (DIM) to determine the optimal lactation period. We therefore examined whether the random regression (RR) coefficient from 306 to 450 DIM (M2) can be predicted from those during the first 305 DIM (M1) by using a random regression model. We analyzed test-day milk records from 85690 Holstein cows in their first lactations and 131727 cows in their later (second to fifth) lactations. Data in M1 and M2 were analyzed separately by using different single-trait RR animal models. We then performed a multiple regression analysis of the RR coefficients of M2 on those of M1 during the first and later lactations. The first-order Legendre polynomials were practical covariates of random regression for the milk yields of M2. All RR coefficients for the additive genetic (AG) effect and the intercept for the permanent environmental (PE) effect of M2 had moderate to strong correlations with the intercept for the AG effect of M1. The coefficients of determination for multiple regression of the combined intercepts for the AG and PE effects of M2 on the coefficients for the AG effect of M1 were moderate to high. The daily milk yields of M2 predicted by using the RR coefficients for the AG effect of M1 were highly correlated with those obtained by using the coefficients of M2. Milk production after 305 DIM can be predicted by using the RR coefficient estimates of the AG effect during the first 305 DIM.

  4. Comparison of adsorption coefficient (K[sub oc]) for soils and HPLC retention factors of aromatic hydrocarbons using a chemically immobilized humic acid column in RP-HPLC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Szabo, G.; Bulman, R.A.

    The determination of soil adsorption coefficients (K[sub oc]) via HPLC capacity factors (k[prime]) has been studied, including the effect of column type and mobile phase composition on the correlation between log K[sub oc] and log k[prime]. K[sub oc] values obtained by procedures other than HPLC correlate well with HPLC capacity factors determined on a chemically immobilized humic acid stationary phase, and it is suggested that this phase is a better model for the sorption onto soil or sediment than the octadecyl-, phenyl- and ethylsilica phases. By using log k[prime][sub w] a theoretical capacity factor has been obtained by extrapolation ofmore » the retention data in a binary solvent system to pure aqueous eluent. There is a better correlation between log K[sub oc] and log k[prime][sub w] than the correlation between log K[sub oc] and log k[prime].« less

  5. The Effect of a Fluorophore Photo-Physics on the Lipid Vesicle Diffusion Coefficient Studied by Fluorescence Correlation Spectroscopy.

    PubMed

    Drabik, Dominik; Przybyło, Magda; Sikorski, Aleksander; Langner, Marek

    2016-03-01

    Fluorescence Correlation Spectroscopy (FCS) is a technique, which allows determination of the diffusion coefficient and concentration of fluorescent objects suspended in the solution. The measured parameter is the fluctuation of the fluorescence signal emitted by diffusing molecules. When 100 nm DOPC vesicles labeled with various fluorescent dyes (Fluorescein-PE, NBD-PE, Atto488 DOPE or βBodipy FL) were measured, different values of diffusion coefficients have been obtained. These diffusion coefficients were different from the expected values measured using the dynamic light scattering method (DLS). The FCS was initially developed for solutions containing small fluorescent molecules therefore the observed inconsistency may result from the nature of vesicle suspension itself. The duration of the fluorescence signal may depend on the following factors: the exposure time of the labeled object to the excitation beam, the photo-physical properties (e.g., stability) of a fluorophore, the theoretical model used for the calculations of the diffusion coefficient and optical properties of the vesicle suspension. The diffusion coefficients determined for differently labeled liposomes show that its dependence on vesicle size and quantity of fluorescent probed used for labeling was significant demonstrating that the fluorescence properties of the fluorophore itself (bleaching and/or blinking) were critical factors for a correct outcome of FCS experiment. The new, based on combined FCS and DLS measurements, method for the determination of the focal volume prove itself to be useful for the evaluation of a fluorescence dye with respect to its applicability for FCS experiment.

  6. An efficient sensitivity analysis method for modified geometry of Macpherson suspension based on Pearson correlation coefficient

    NASA Astrophysics Data System (ADS)

    Shojaeefard, Mohammad Hasan; Khalkhali, Abolfazl; Yarmohammadisatri, Sadegh

    2017-06-01

    The main purpose of this paper is to propose a new method for designing Macpherson suspension, based on the Sobol indices in terms of Pearson correlation which determines the importance of each member on the behaviour of vehicle suspension. The formulation of dynamic analysis of Macpherson suspension system is developed using the suspension members as the modified links in order to achieve the desired kinematic behaviour. The mechanical system is replaced with an equivalent constrained links and then kinematic laws are utilised to obtain a new modified geometry of Macpherson suspension. The equivalent mechanism of Macpherson suspension increased the speed of analysis and reduced its complexity. The ADAMS/CAR software is utilised to simulate a full vehicle, Renault Logan car, in order to analyse the accuracy of modified geometry model. An experimental 4-poster test rig is considered for validating both ADAMS/CAR simulation and analytical geometry model. Pearson correlation coefficient is applied to analyse the sensitivity of each suspension member according to vehicle objective functions such as sprung mass acceleration, etc. Besides this matter, the estimation of Pearson correlation coefficient between variables is analysed in this method. It is understood that the Pearson correlation coefficient is an efficient method for analysing the vehicle suspension which leads to a better design of Macpherson suspension system.

  7. Fully automated, deep learning segmentation of oxygen-induced retinopathy images

    PubMed Central

    Xiao, Sa; Bucher, Felicitas; Wu, Yue; Rokem, Ariel; Lee, Cecilia S.; Marra, Kyle V.; Fallon, Regis; Diaz-Aguilar, Sophia; Aguilar, Edith; Friedlander, Martin; Lee, Aaron Y.

    2017-01-01

    Oxygen-induced retinopathy (OIR) is a widely used model to study ischemia-driven neovascularization (NV) in the retina and to serve in proof-of-concept studies in evaluating antiangiogenic drugs for ocular, as well as nonocular, diseases. The primary parameters that are analyzed in this mouse model include the percentage of retina with vaso-obliteration (VO) and NV areas. However, quantification of these two key variables comes with a great challenge due to the requirement of human experts to read the images. Human readers are costly, time-consuming, and subject to bias. Using recent advances in machine learning and computer vision, we trained deep learning neural networks using over a thousand segmentations to fully automate segmentation in OIR images. While determining the percentage area of VO, our algorithm achieved a similar range of correlation coefficients to that of expert inter-human correlation coefficients. In addition, our algorithm achieved a higher range of correlation coefficients compared with inter-expert correlation coefficients for quantification of the percentage area of neovascular tufts. In summary, we have created an open-source, fully automated pipeline for the quantification of key values of OIR images using deep learning neural networks. PMID:29263301

  8. The Proper Sequence for Correcting Correlation Coefficients for Range Restriction and Unreliability.

    ERIC Educational Resources Information Center

    Stauffer, Joseph M.; Mendoza, Jorge L.

    2001-01-01

    Uses classical test theory to show that it is the nature of the range restriction, rather than the nature of the available reliability coefficient, that determines the sequence for applying corrections for range restriction and unreliability. Shows how the common rule of thumb for choosing the sequence is tenable only when the correction does not…

  9. Preliminary appraisal of the reliability and validity of the Colorado State University Feline Acute Pain Scale.

    PubMed

    Shipley, Hilary; Guedes, Alonso; Graham, Lynelle; Goudie-DeAngelis, Elizabeth; Wendt-Hornickle, Erin

    2018-05-01

    Objectives The objective of this study was to determine the inter-rater reliability and convergent validity of the Colorado State University Feline Acute Pain Scale (CSU-FAPS) in a preliminary appraisal of its performance in a clinical teaching setting. Methods Sixty-eight female cats were assessed for pain after ovariohysterectomy. A cohort of 21 cats was examined independently by four raters (two board-certified anesthesiologists and two anesthesia residents) with the CSU-FAPS, and intra-class correlation coefficient (ICC) was used to determine inter-rater reliability. Weighted Cohen's kappa was used to determine inter-rater reliability centered on the 'need to reassess analgesic plan' (dichotomous scale). A separate cohort of 47 cats was evaluated independently by two raters (one board-certified anesthesiologist and one veterinary small animal rotating intern) using the CSU-FAPS and the Glasgow Composite Measure Pain Scale (CMPS-Feline), and Spearman rank-order correlation was determined to assess convergent validity. Reliability was interpreted using Altman's classification as very good, good, moderate, fair and poor. Validity was considered adequate if correlation coefficients were between 0.4 and 0.8. Results The ICC was 0.61 for anesthesiologists and 0.67 for residents, indicating good reliability. Weighted Cohen's kappa was 0.79 for anesthesiologists and 0.44 for residents, indicating moderate to good reliability. The Spearman rank correlation indicated a statistically significant ( P = 0.0003) positive correlation (0.31; 95% confidence interval 0.14-0.46) between the CSU-FAPS and the CMPS-Feline. Conclusions and relevance The CSU-FAPS showed moderate-to-good inter-rater reliability when used by veterinarians to assess pain level or need to reassess analgesic plan after ovariohysterectomy in cats. The validity fell short of current guidelines for correlation coefficients and further refinement and testing are warranted to improve its performance.

  10. LASER BIOLOGY AND MEDICINE: Application of laser fluorimetry for determining the influence of a single amino-acid substitution on the individual photophysical parameters of a fluorescent form of a fluorescent protein mRFP1

    NASA Astrophysics Data System (ADS)

    Banishev, A. A.; Vrzheshch, E. P.; Shirshin, E. A.

    2009-03-01

    Individual photophysical parameters of the chromophore of a fluorescent protein mRFP1 and its two mutants (amino-acid substitution at position 66 - mRFP1/ Q66C and mRFP1/Q66S proteins) are determined. For this purpose, apart from conventional methods of fluorimetry and spectrophotometry, nonlinear laser fluorimetry is used. It is shown that the individual extinction coefficients of the chromophore of proteins correlate (correlation coefficient above 0.9) with the volume of the substituted amino-acid residue at position 66 (similar to the positions of the absorption, fluorescence excitation and emission maxima).

  11. Accuracy of contrast-enhanced spectral mammography for estimating residual tumor size after neoadjuvant chemotherapy in patients with breast cancer: a feasibility study

    PubMed Central

    Barra, Filipe Ramos; de Souza, Fernanda Freire; Camelo, Rosimara Eva Ferreira Almeida; Ribeiro, Andrea Campos de Oliveira; Farage, Luciano

    2017-01-01

    Objective To assess the feasibility of contrast-enhanced spectral mammography (CESM) of the breast for assessing the size of residual tumors after neoadjuvant chemotherapy (NAC). Materials and methods In breast cancer patients who underwent NAC between 2011 and 2013, we evaluated residual tumor measurements obtained with CESM and full-field digital mammography (FFDM). We determined the concordance between the methods, as well as their level of agreement with the pathology. Three radiologists analyzed eight CESM and FFDM measurements separately, considering the size of the residual tumor at its largest diameter and correlating it with that determined in the pathological analysis. Interobserver agreement was also evaluated. Results The sensitivity, specificity, positive predictive value, and negative predictive value were higher for CESM than for FFDM (83.33%, 100%, 100%, and 66% vs. 50%, 50%, 50%, and 25%, respectively). The CESM measurements showed a strong, consistent correlation with the pathological findings (correlation coefficient = 0.76-0.92; intraclass correlation coefficient = 0.692-0.886). The correlation between the FFDM measurements and the pathological findings was not statistically significant, with questionable consistency (intraclass correlation coefficient = 0.488-0.598). Agreement with the pathological findings was narrower for CESM measurements than for FFDM measurements. Interobserver agreement was higher for CESM than for FFDM (0.94 vs. 0.88). Conclusion CESM is a feasible means of evaluating residual tumor size after NAC, showing a good correlation and good agreement with pathological findings. For CESM measurements, the interobserver agreement was excellent. PMID:28894329

  12. The Stayhealthy bioelectrical impedance analyzer predicts body fat in children and adults.

    PubMed

    Erceg, David N; Dieli-Conwright, Christina M; Rossuello, Amerigo E; Jensky, Nicole E; Sun, Stephanie; Schroeder, E Todd

    2010-05-01

    Bioelectrical impedance analysis (BIA) is a time-efficient and cost-effective method for estimating body composition. We hypothesized that there would be no significant difference between the Stayhealthy BC1 BIA and the selected reference methods when determining body composition. Thus, the purpose of the present study was to determine the validity of estimating percent body fat (%BF) using the Stayhealthy BIA with its most recently updated algorithms compared to the reference methods of dual-energy x-ray absorptiometry for adults and hydrostatic weighing for children. We measured %BF in 245 adults aged 18 to 80 years and 115 children aged 10 to 17 years. Body fat by BIA was determined using a single 50 kHz frequency handheld impedance device and proprietary software. Agreement between BIA and reference methods was assessed by Bland and Altman plots. Bland and Altman analysis for men, women, and children revealed good agreement between the reference methods and BIA. There was no significant difference by t tests between mean %BF by BIA for men, women, or children when compared to the respective reference method. Significant correlation values between BIA, and reference methods for all men, women, and children were 0.85, 0.88, and 0.79, respectively. Reliability (test-retest) was assessed by intraclass correlation coefficient and coefficient of variation. Intraclass correlation coefficient values were greater than 0.99 (P < .001) for men, women, and children with coefficient of variation values 3.3%, 1.8%, and 1.7%, respectively. The Stayhealthy BIA device demonstrated good agreement between reference methods using Bland and Altman analyses. Copyright 2010 Elsevier Inc. All rights reserved.

  13. [Rapid prediction of annual ring density of Paulownia elongate standing tress using near infrared spectroscopy].

    PubMed

    Jiang, Ze-Hui; Wang, Yu-Rong; Fei, Ben-Hua; Fu, Feng; Hse, Chung-Yun

    2007-06-01

    Rapid prediction of annual ring density of Paulownia elongate standing trees using near infrared spectroscopy was studied. It was non-destructive to collect the samples for trees, that is, the wood cores 5 mm in diameter were unthreaded at the breast height of standing trees instead of fallen trees. Then the spectra data were collected by autoscan method of NIR. The annual ring density was determined by mercury immersion. And the models were made and analyzed by the partial least square (PLS) and full cross validation in the 350-2 500 nm wavelength range. The results showed that high coefficients were obtained between the annual ring and the NIR fitted data. The correlation coefficient of prediction model was 0.88 and 0.91 in the middle diameter and bigger diameter, respectively. Moreover, high coefficients of correlation were also obtained between annual ring density laboratory-determined and the NIR fitted data in the middle diameter of Paulownia elongate standing trees, the correlation coefficient of calibration model and prediction model were 0.90 and 0.83, and the standard errors of calibration (SEC) and standard errors of prediction(SEP) were 0.012 and 0.016, respectively. The method can simply, rapidly and non-destructively estimate the annual ring density of the Paulownia elongate standing trees close to the cutting age.

  14. Source Determination of Red Gel Pen Inks using Raman Spectroscopy and Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy combined with Pearson's Product Moment Correlation Coefficients and Principal Component Analysis.

    PubMed

    Mohamad Asri, Muhammad Naeim; Mat Desa, Wan Nur Syuhaila; Ismail, Dzulkiflee

    2018-01-01

    The potential combination of two nondestructive techniques, that is, Raman spectroscopy (RS) and attenuated total reflectance-fourier transform infrared (ATR-FTIR) spectroscopy with Pearson's product moment correlation (PPMC) coefficient (r) and principal component analysis (PCA) to determine the actual source of red gel pen ink used to write a simulated threatening note, was examined. Eighteen (18) red gel pens purchased from Japan and Malaysia from November to December 2014 where one of the pens was used to write a simulated threatening note were analyzed using RS and ATR-FTIR spectroscopy, respectively. The spectra of all the red gel pen inks including the ink deposited on the simulated threatening note gathered from the RS and ATR-FTIR analyses were subjected to PPMC coefficient (r) calculation and principal component analysis (PCA). The coefficients r = 0.9985 and r = 0.9912 for pairwise combination of RS and ATR-FTIR spectra respectively and similarities in terms of PC1 and PC2 scores of one of the inks to the ink deposited on the simulated threatening note substantiated the feasibility of combining RS and ATR-FTIR spectroscopy with PPMC coefficient (r) and PCA for successful source determination of red gel pen inks. The development of pigment spectral library had allowed the ink deposited on the threatening note to be identified as XSL Poppy Red (CI Pigment Red 112). © 2017 American Academy of Forensic Sciences.

  15. Spatial distribution of SPAD value and determination of the suitable leaf for N diagnosis in cucumber

    NASA Astrophysics Data System (ADS)

    Hu, Jing; Li, Chenxiao; Wen, Yifang; Gao, Xinhao; Shi, Feifei; Han, Luhua

    2018-01-01

    To determine the best leaf position for nitrogen diagnosis in cucumber with SPAD meter, greenhouse experiments were carried out to study spatial distribution of SPAD value of different position of the 3rd fully expanded cucumber leaf in the effect of different nitrogen levels, and the correlations between SPAD values and nitrogen concentration of chlorophyll. The results show that there is remarkable different SPAD value in different positions of the 3rd fully expanded leaf in the flowering and fruiting stage. Comparing the coefficients of SPAD value variation, we find that the coefficient of variation of leaf edge was significantly higher than the edge of the main vein, and the coefficient of variation of triangular area of leaf tip is significantly higher than any other leaf area. There is a significant correlation between SPAD values and leaf nitrogen content. Preliminary study shows that triangular area of leaf tip from the 20% leaf tip to leaf edge is the best position for nitrogen diagnosis.

  16. Experimental determination of convective heat transfer coefficients in the separated flow region of the Space Shuttle Solid Rocket Motor

    NASA Technical Reports Server (NTRS)

    Whitesides, R. Harold; Majumdar, Alok K.; Jenkins, Susan L.; Bacchus, David L.

    1990-01-01

    A series of cold flow heat transfer tests was conducted with a 7.5-percent scale model of the Space Shuttle Rocket Motor (SRM) to measure the heat transfer coefficients in the separated flow region around the nose of the submerged nozzle. Modifications were made to an existing 7.5 percent scale model of the internal geometry of the aft end of the SRM, including the gimballed nozzle in order to accomplish the measurements. The model nozzle nose was fitted with a stainless steel shell with numerous thermocouples welded to the backside of the thin wall. A transient 'thin skin' experimental technique was used to measure the local heat transfer coefficients. The effects of Reynolds number, nozzle gimbal angle, and model location were correlated with a Stanton number versus Reynolds number correlation which may be used to determine the convective heating rates for the full scale Space Shuttle Solid Rocket Motor nozzle.

  17. Semimajor Axis Estimation Strategies

    NASA Technical Reports Server (NTRS)

    How, Jonathan P.; Alfriend, Kyle T.; Breger, Louis; Mitchell, Megan

    2004-01-01

    This paper extends previous analysis on the impact of sensing noise for the navigation and control aspects of formation flying spacecraft. We analyze the use of Carrier-phase Differential GPS (CDGPS) in relative navigation filters, with a particular focus on the filter correlation coefficient. This work was motivated by previous publications which suggested that a "good" navigation filter would have a strong correlation (i.e., coefficient near -1) to reduce the semimajor axis (SMA) error, and therefore, the overall fuel use. However, practical experience with CDGPS-based filters has shown this strong correlation seldom occurs (typical correlations approx. -0.1), even when the estimation accuracies are very good. We derive an analytic estimate of the filter correlation coefficient and demonstrate that, for the process and sensor noises levels expected with CDGPS, the expected value will be very low. It is also demonstrated that this correlation can be improved by increasing the time step of the discrete Kalman filter, but since the balance condition is not satisfied, the SMA error also increases. These observations are verified with several linear simulations. The combination of these simulations and analysis provide new insights on the crucial role of the process noise in determining the semimajor axis knowledge.

  18. Onabotulinum toxin A dosage trends over time for adductor spasmodic dysphonia: A 15-year experience.

    PubMed

    Tang, Christopher G; Novakovic, Daniel; Mor, Niv; Blitzer, Andrew

    2016-03-01

    Although onabotulinum neurotoxin A (BoNTA) has been used for over three decades for the treatment of adductor spasmodic dysphonia, no study has been performed to look at the trend of BoNTA dosages across time. The goal of this study is to evaluate the dosage trends to determine if the dosage necessary for voice improvement in patients increases over time. Charts were reviewed for patients with 15 years or more of experience. Linear regression analysis was performed to determine correlation coefficients and trends. Fifty-five patients receiving BoNTA injections by the senior author (a.b.) for over 15 years were evaluated. Thirty-nine patients (82% female) met inclusion criteria. Patients received injections over an average of 18.6 years ± 1.36 years, with the longest follow-up of 21.5 years. Of 39 patients, 16 (41%) had a negative correlation coefficient (Pearson's r) suggesting a decrease over time, whereas 23 (59%) had a positive correlation coefficient suggesting an increase over time. The mean correlation coefficient was 0.139 ± 0.534 and P < 0.05 in 19 patients and P > 0.05 in 20 patients. R(2) for all patients were less than 0.75. Onabotulinum neurotoxin A injection dosage trends vary depending on the individual over time. Overall, the dose range appears to be stable in the majority of patients, suggesting that tolerance does not play a significant part in dose variation over time. 4. Laryngoscope, 126:678-681, 2016. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Estimating the Diffusion Coefficients of Sugars Using Diffusion Experiments in Agar-Gel and Computer Simulations.

    PubMed

    Miyamoto, Shuichi; Atsuyama, Kenji; Ekino, Keisuke; Shin, Takashi

    2018-01-01

    The isolation of useful microbes is one of the traditional approaches for the lead generation in drug discovery. As an effective technique for microbe isolation, we recently developed a multidimensional diffusion-based gradient culture system of microbes. In order to enhance the utility of the system, it is favorable to have diffusion coefficients of nutrients such as sugars in the culture medium beforehand. We have, therefore, built a simple and convenient experimental system that uses agar-gel to observe diffusion. Next, we performed computer simulations-based on random-walk concepts-of the experimental diffusion system and derived correlation formulas that relate observable diffusion data to diffusion coefficients. Finally, we applied these correlation formulas to our experimentally-determined diffusion data to estimate the diffusion coefficients of sugars. Our values for these coefficients agree reasonably well with values published in the literature. The effectiveness of our simple technique, which has elucidated the diffusion coefficients of some molecules which are rarely reported (e.g., galactose, trehalose, and glycerol) is demonstrated by the strong correspondence between the literature values and those obtained in our experiments.

  20. The Consumer Quality Index in an accident and emergency department: internal consistency, validity and discriminative capacity.

    PubMed

    Bos, Nanne; Sturms, Leontien M; Stellato, Rebecca K; Schrijvers, Augustinus J P; van Stel, Henk F

    2015-10-01

    Patients' experiences are an indicator of health-care performance in the accident and emergency department (A&E). The Consumer Quality Index for the Accident and Emergency department (CQI A&E), a questionnaire to assess the quality of care as experienced by patients, was investigated. The internal consistency, construct validity and discriminative capacity of the questionnaire were examined. In the Netherlands, twenty-one A&Es participated in a cross-sectional survey, covering 4883 patients. The questionnaire consisted of 78 questions. Principal components analysis determined underlying domains. Internal consistency was determined by Cronbach's alpha coefficients, construct validity by Pearson's correlation coefficients and the discriminative capacity by intraclass correlation coefficients and reliability of A&E-level mean scores (G-coefficient). Seven quality domains emerged from the principal components analysis: information before treatment, timeliness, attitude of health-care professionals, professionalism of received care, information during treatment, environment and facilities, and discharge management. Domains were internally consistent (range: 0.67-0.84). Five domains and the 'global quality rating' had the capacity to discriminate among A&Es (significant intraclass correlation coefficient). Four domains and the 'global quality rating' were close to or above the threshold for reliably demonstrating differences among A&Es. The patients' experiences score on the domain timeliness showed the largest range between the worst- and best-performing A&E. The CQI A&E is a validated survey to measure health-care performance in the A&E from patients' perspective. Five domains regarding quality of care aspects and the 'global quality rating' had the capacity to discriminate among A&Es. © 2013 John Wiley & Sons Ltd.

  1. Relationships between water quality parameters in rivers and lakes: BOD5, COD, NBOPs, and TOC.

    PubMed

    Lee, Jaewoong; Lee, Seunghyun; Yu, Soonju; Rhew, Doughee

    2016-04-01

    Biological oxygen demand (BOD5) or chemical oxygen demand (COD) analysis is widely used to evaluate organic pollutants in water systems as well as the efficiency of wastewater treatment plants. However, both analysis methods have restrictions such as being insensitive, imprecise, time-consuming, and the production of chemical waste. Therefore, total organic carbon (TOC) analysis for organic pollutants has been considered for an alternative analysis instead of BOD5 or COD. Several studies have investigated the replacement of BOD5 or COD with TOC in wastewater samples; however, few studies have investigated the relationships between water quality parameters in rivers and lakes. Therefore, this study evaluated the relationships between BOD5, COD, or NBOPs and TOC by the analysis of national water quality monitoring data of rivers and lakes for 5 years. High correlation coefficients (r) of 0.87 and 0.66 between BOD5 and TOC (p < 0.05) were obtained for rivers and lakes, respectively, and strong correlation coefficients (r) of 0.93 and 0.75 were observed between COD and TOC (p < 0.05) for rivers and lakes, respectively. The correlation coefficient (r) between NBOPs and TOC was 0.93 for rivers and 0.72 for lakes. The coefficients of determination (R 2) were 0.75 and 0.44 between BOD5 and TOC for rivers and lakes as well as were 0.87 and 0.57 between COD and TOC for rivers and lakes, respectively. The coefficient of determination (R 2) between NBOPs and TOC was 0.73 for rivers and 0.52 for lakes.

  2. Diffusion and solubility coefficients determined by permeation and immersion experiments for organic solvents in HDPE geomembrane.

    PubMed

    Chao, Keh-Ping; Wang, Ping; Wang, Ya-Ting

    2007-04-02

    The chemical resistance of eight organic solvents in high density polyethylene (HDPE) geomembrane has been investigated using the ASTM F739 permeation method and the immersion test at different temperatures. The diffusion of the experimental organic solvents in HDPE geomembrane was non-Fickian kinetic, and the solubility coefficients can be consistent with the solubility parameter theory. The diffusion coefficients and solubility coefficients determined by the ASTM F739 method were significantly correlated to the immersion tests (p<0.001). The steady state permeation rates also showed a good agreement between ASTM F739 and immersion experiments (r(2)=0.973, p<0.001). Using a one-dimensional diffusion equation based on Fick's second law, the diffusion and solubility coefficients obtained by immersion test resulted in over estimates of the ASTM F739 permeation results. The modeling results indicated that the diffusion and solubility coefficients should be obtained using ASTM F739 method which closely simulates the practical application of HDPE as barriers in the field.

  3. Fixed-bed column studies of total organic carbon removal from industrial wastewater by use of diatomite decorated with polyethylenimine-functionalized pyroxene nanoparticles.

    PubMed

    Hethnawi, Afif; Manasrah, Abdallah D; Vitale, Gerardo; Nassar, Nashaat N

    2018-03-01

    In this study, a fixed-bed column adsorption process was employed to remove organic pollutants from a real industrial wastewater effluent using polyethylenimine-functionalized pyroxene nanoparticles (PEI-PY) embedded into Diatomite at very low mass percentage. Various dynamic parameters (e.g., inlet concentration, inlet flow rate, bed height, and PEI-nanoparticle concentration in Diatomite, (%nps)) were investigated to determine the breakthrough behavior. The obtained breakthrough curves were fit with a convection-dispersion model to determine the characteristic parameters based on mass transfer phenomena. The axial dispersion coefficient (D L ) and group of dimensionless numbers; including Renold number (Re), Schmidt number (Sc), and Sherwood number (Sh) were all determined and correlated by Wilson-Geankoplis correlation that was used to estimate the external film diffusion coefficients (Kc) at 0.0015 < Re<55. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Mental Health Has a Stronger Association with Patient-Reported Shoulder Pain and Function Than Tear Size in Patients with Full-Thickness Rotator Cuff Tears.

    PubMed

    Wylie, James D; Suter, Thomas; Potter, Michael Q; Granger, Erin K; Tashjian, Robert Z

    2016-02-17

    Patient-reported outcome measures have increasingly accompanied objective examination findings in the evaluation of orthopaedic interventions. Our objective was to determine whether a validated measure of mental health (Short Form-36 Mental Component Summary [SF-36 MCS]) or measures of tear severity on magnetic resonance imaging were more strongly associated with self-assessed shoulder pain and function in patients with symptomatic full-thickness rotator cuff tears. One hundred and sixty-nine patients with full-thickness rotator cuff tears were prospectively enrolled. Patients completed the Short Form-36, visual analog scales for shoulder pain and function, the Simple Shoulder Test (SST), and the American Shoulder and Elbow Surgeons (ASES) instrument at the time of diagnosis. Shoulder magnetic resonance imaging examinations were reviewed to document the number of tendons involved, tear size, tendon retraction, and tear surface area. Age, sex, body mass index, number of medical comorbidities, smoking status, and Workers' Compensation status were recorded. Bivariate correlations and multivariate regression models were calculated to identify associations with baseline shoulder scores. The SF-36 MCS had the strongest correlation with the visual analog scale for shoulder pain (Pearson correlation coefficient, -0.48; p < 0.001), the visual analog scale for shoulder function (Pearson correlation coefficient, -0.33; p < 0.001), the SST (Pearson correlation coefficient, 0.37; p < 0.001), and the ASES score (Pearson correlation coefficient, 0.51; p < 0.001). Tear severity only correlated with the visual analog scale for shoulder function; the Pearson correlation coefficient was 0.19 for tear size (p = 0.018), 0.18 for tendon retraction (p = 0.025), 0.18 for tear area (p = 0.022), and 0.20 for the number of tendons involved (p = 0.011). Tear severity did not correlate with other scores in bivariate correlations (all p > 0.05). In all multivariate models, the SF-36 MCS had the strongest association with the visual analog scale for shoulder pain, the visual analog scale for shoulder function, the SST, and the ASES score (all p < 0.001). Patient mental health may play an influential role in patient-reported pain and function in patients with full-thickness rotator cuff tears. Further studies are needed to determine its effect on the outcome of the treatment of rotator cuff disease. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  5. Precision islands in the Ising and O(N ) models

    DOE PAGES

    Kos, Filip; Poland, David; Simmons-Duffin, David; ...

    2016-08-04

    We make precise determinations of the leading scaling dimensions and operator product expansion (OPE) coefficients in the 3d Ising, O(2), and O(3) models from the conformal bootstrap with mixed correlators. We improve on previous studies by scanning over possible relative values of the leading OPE coefficients, which incorporates the physical information that there is only a single operator at a given scaling dimension. The scaling dimensions and OPE coefficients obtained for the 3d Ising model, (Δ σ , Δ ϵ , λ σσϵ , λ ϵϵϵ ) = (0.5181489(10), 1.412625(10), 1.0518537(41), 1.532435(19) , give the most precise determinations of thesemore » quantities to date.« less

  6. Influence of Social and Behavioural Characteristics of Users on Their Evaluation of Subjective Loudness and Acoustic Comfort in Shopping Malls

    PubMed Central

    Meng, Qi; Kang, Jian

    2013-01-01

    A large-scale subjective survey was conducted in six shopping malls in Harbin City, China, to determine the influence of social and behavioural characteristics of users on their evaluation of subjective loudness and acoustic comfort. The analysis of social characteristics shows that evaluation of subjective loudness is influenced by income and occupation, with correlation coefficients or contingency coefficients of 0.10 to 0.40 (p<0.05 or p<0.01). Meanwhile, evaluation of acoustic comfort evaluation is influenced by income, education level, and occupation, with correlation coefficients or contingency coefficients of 0.10 to 0.60 (p<0.05 or p<0.01). The effect of gender and age on evaluation of subjective loudness and acoustic comfort is statistically insignificant. The effects of occupation are mainly caused by the differences in income and education level, in which the effects of income are greater than that of education level. In terms of behavioural characteristics, evaluation of subjective loudness is influenced by the reason for visit, frequency of visit, and length of stay, with correlation coefficients or contingency coefficients of 0.10 to 0.40 (p<0.05 or p<0.01). Evaluation of acoustic comfort is influenced by the reason for visit to the site, the frequency of visit, length of stay, and also season of visit, with correlation coefficients of 0.10 to 0.30 (p<0.05 or p<0.01). In particular, users who are waiting for someone show lower evaluation of acoustic comfort, whereas users who go to shopping malls more than once a month show higher evaluation of acoustic comfort. On the contrary, the influence of the period of visit and the accompanying persons are found insignificant. PMID:23336003

  7. Classical Wigner method with an effective quantum force: application to reaction rates.

    PubMed

    Poulsen, Jens Aage; Li, Huaqing; Nyman, Gunnar

    2009-07-14

    We construct an effective "quantum force" to be used in the classical molecular dynamics part of the classical Wigner method when determining correlation functions. The quantum force is obtained by estimating the most important short time separation of the Feynman paths that enter into the expression for the correlation function. The evaluation of the force is then as easy as classical potential energy evaluations. The ideas are tested on three reaction rate problems. The resulting transmission coefficients are in much better agreement with accurate results than transmission coefficients from the ordinary classical Wigner method.

  8. Volumetric segmentation of ADC maps and utility of standard deviation as measure of tumor heterogeneity in soft tissue tumors.

    PubMed

    Singer, Adam D; Pattany, Pradip M; Fayad, Laura M; Tresley, Jonathan; Subhawong, Ty K

    2016-01-01

    Determine interobserver concordance of semiautomated three-dimensional volumetric and two-dimensional manual measurements of apparent diffusion coefficient (ADC) values in soft tissue masses (STMs) and explore standard deviation (SD) as a measure of tumor ADC heterogeneity. Concordance correlation coefficients for mean ADC increased with more extensive sampling. Agreement on the SD of tumor ADC values was better for large regions of interest and multislice methods. Correlation between mean and SD ADC was low, suggesting that these parameters are relatively independent. Mean ADC of STMs can be determined by volumetric quantification with high interobserver agreement. STM heterogeneity merits further investigation as a potential imaging biomarker that complements other functional magnetic resonance imaging parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Accuracy of MRI skeletal age estimation for subjects 12-19. Potential use for subjects of unknown age.

    PubMed

    Serinelli, Serenella; Panebianco, Valeria; Martino, Milvia; Battisti, Sofia; Rodacki, Karina; Marinelli, Enrico; Zaccagna, Fulvio; Semelka, Richard C; Tomei, Ernesto

    2015-05-01

    In forensic practice, there is a growing need for accurate methods of age estimation, especially in the cases of young individuals of unknown age. Age can be estimated through somatic features that are universally considered associated with chronological age. Unfortunately, these features do not always coincide with the real chronological age: for these reasons that age determination is often very difficult. Our aim is to evaluate accuracy of skeletal age estimation using Tomei's MRI method in subjects between 12 and 19 years old for forensic purposes. Two investigators analyzed MRI images of the left hand and wrist of 77 male and 74 female caucasian subjects, without chronic diseases or developmental disorders, whose age ranged from 12 to 19 years. Skeletal maturation was determined by two operators, who analyzed all MRI images separately, in blinded fashion to the chronological age. Inter-rater agreement was measured with Pearson (R (2)) coefficient. One of the examiners repeated the evaluation after 6 months, and intraobserver variation was analyzed. Bland-Altman plots were used to determine mean differences between skeletal and chronological age. Inter-rater agreement Pearson coefficient showed a good linear correlation, respectively, 0.98 and 0.97 in males and females. Bland-Altman analysis demonstrated that the differences between chronological and skeletal age are not significant. Spearman's correlation coefficient showed good correlation between skeletal and chronological age both in females (R (2) = 0.96) and in males (R (2) = 0.94). Our results show that MRI skeletal age is a reproducible method and has good correlation with chronological age.

  10. Simple, simultaneous gravimetric determination of calcite and dolomite in calcareous soils

    USDA-ARS?s Scientific Manuscript database

    Literature pertaining to determination of calcite and dolomite is not modern and describes slow methods that require expensive specialized apparatus. The objective of this paper was to describe a new method that requires no specialized equipment. Linear regressions and correlation coefficients for...

  11. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale

    PubMed Central

    2013-01-01

    Background Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. Results A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham’s π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. Conclusion The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/− 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale. PMID:24289110

  12. Correlation between mass transfer coefficient kLa and relevant operating parameters in cylindrical disposable shaken bioreactors on a bench-to-pilot scale.

    PubMed

    Klöckner, Wolf; Gacem, Riad; Anderlei, Tibor; Raven, Nicole; Schillberg, Stefan; Lattermann, Clemens; Büchs, Jochen

    2013-12-02

    Among disposable bioreactor systems, cylindrical orbitally shaken bioreactors show important advantages. They provide a well-defined hydrodynamic flow combined with excellent mixing and oxygen transfer for mammalian and plant cell cultivations. Since there is no known universal correlation between the volumetric mass transfer coefficient for oxygen kLa and relevant operating parameters in such bioreactor systems, the aim of this current study is to experimentally determine a universal kLa correlation. A Respiration Activity Monitoring System (RAMOS) was used to measure kLa values in cylindrical disposable shaken bioreactors and Buckingham's π-Theorem was applied to define a dimensionless equation for kLa. In this way, a scale- and volume-independent kLa correlation was developed and validated in bioreactors with volumes from 2 L to 200 L. The final correlation was used to calculate cultivation parameters at different scales to allow a sufficient oxygen supply of tobacco BY-2 cell suspension cultures. The resulting equation can be universally applied to calculate the mass transfer coefficient for any of seven relevant cultivation parameters such as the reactor diameter, the shaking frequency, the filling volume, the viscosity, the oxygen diffusion coefficient, the gravitational acceleration or the shaking diameter within an accuracy range of +/- 30%. To our knowledge, this is the first kLa correlation that has been defined and validated for the cited bioreactor system on a bench-to-pilot scale.

  13. Vasoconstriction Potency Induced by Aminoamide Local Anesthetics Correlates with Lipid Solubility

    PubMed Central

    Sung, Hui-Jin; Ok, Seong-Ho; Sohn, Jin-Young; Son, Yong Hyeok; Kim, Jun Kyu; Lee, Soo Hee; Han, Jeong Yeol; Lim, Dong Hoon; Shin, Il-Woo; Lee, Heon-Keun; Chung, Young-Kyun; Choi, Mun-Jeoung; Sohn, Ju-Tae

    2012-01-01

    Aminoamide local anesthetics induce vasoconstriction in vivo and in vitro. The goals of this in vitro study were to investigate the potency of local anesthetic-induced vasoconstriction and to identify the physicochemical property (octanol/buffer partition coefficient, pKa, molecular weight, or potency) of local anesthetics that determines their potency in inducing isolated rat aortic ring contraction. Cumulative concentration-response curves to local anesthetics (levobupivacaine, ropivacaine, lidocaine, and mepivacaine) were obtained from isolated rat aorta. Regression analyses were performed to determine the relationship between the reported physicochemical properties of local anesthetics and the local anesthetic concentration that produced 50% (ED50) of the local anesthetic-induced maximum vasoconstriction. We determined the order of potency (ED50) of vasoconstriction among local anesthetics to be levobupivacaine > ropivacaine > lidocaine > mepivacaine. The relative importance of the independent variables that affect the vasoconstriction potency is octanol/buffer partition coefficient > potency > pKa > molecular weight. The ED50 in endothelium-denuded aorta negatively correlated with the octanol/buffer partition coefficient of local anesthetics (r2 = 0.9563; P < 0.001). The potency of the vasoconstriction in the endothelium-denuded aorta induced by local anesthetics is determined primarily by lipid solubility and, in part, by other physicochemical properties including potency and pKa. PMID:22778542

  14. Correlation between pre-pregnancy body mass index and maternal visceral adiposity with fetal biometry during the second trimester.

    PubMed

    Lopes, Karina R M; Souza, Alex Sandro R; Figueiroa, José N; Alves, João Guilherme B

    2017-08-01

    To determine the correlation between pre-pregnancy body mass index (BMI) and maternal visceral adiposity with fetal biometry during the second trimester. A cross-sectional observational study was conducted among pregnant women who received prenatal care at a center in Recife, Brazil, between October 3, 2011, and September 27, 2013. Pre-pregnancy BMI was determined at the first prenatal care visit. Maternal visceral adiposity and fetal biometry were measured at the same ultrasonography session. The associations between maternal and fetal variables were evaluated using the Pearson correlation coefficient (R). The Student t test was used to test the null hypothesis of adjusted correlation coefficients. Overall, 740 women were included. No correlation was found between pre-pregnancy BMI and any of the fetal biometric variables assessed. By contrast, maternal visceral adiposity positively correlated with fetal abdominal circumference (R=0.529), estimated fetal weight (R=0.524), head circumference (R=0.521), femur length (R=0.521), and biparietal diameter (R=0.524; P<0.001 for all fetal variables). These findings remained statistically significant after controlling for pregnancy length. Maternal visceral adiposity, but not pre-pregnancy BMI, positively correlated with fetal biometry during the second trimester. © 2017 International Federation of Gynecology and Obstetrics.

  15. Correlation of published data on the solubility of methane in H/sub 2/O-NaCl solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coco, L.T.; Johnson, A.E. Jr.; Bebout, D.G.

    1981-01-01

    A new correlation of the available published data for the solubility of methane in water was developed, based on fundamental thermodynamic relationships. An empirical relationship for the salting-out coefficient of NaCl for methane solubility in water was determined as a function of temperature. Root mean square and average deviations for the new correlation, the Haas correlation, and the revised Blount equation are compared.

  16. Multiparametric voxel-based analyses of standardized uptake values and apparent diffusion coefficients of soft-tissue tumours with a positron emission tomography/magnetic resonance system: Preliminary results.

    PubMed

    Sagiyama, Koji; Watanabe, Yuji; Kamei, Ryotaro; Hong, Sungtak; Kawanami, Satoshi; Matsumoto, Yoshihiro; Honda, Hiroshi

    2017-12-01

    To investigate the usefulness of voxel-based analysis of standardized uptake values (SUVs) and apparent diffusion coefficients (ADCs) for evaluating soft-tissue tumour malignancy with a PET/MR system. Thirty-five subjects with either ten low/intermediate-grade tumours or 25 high-grade tumours were prospectively enrolled. Zoomed diffusion-weighted and fluorodeoxyglucose ( 18 FDG)-PET images were acquired along with fat-suppressed T2-weighted images (FST2WIs). Regions of interest (ROIs) were drawn on FST2WIs including the tumour in all slices. ROIs were pasted onto PET and ADC-maps to measure SUVs and ADCs within tumour ROIs. Tumour volume, SUVmax, ADCminimum, the heterogeneity and the correlation coefficients of SUV and ADC were recorded. The parameters of high- and low/intermediate-grade groups were compared, and receiver operating characteristic (ROC) analysis was also performed. The mean correlation coefficient for SUV and ADC in high-grade sarcomas was lower than that of low/intermediate-grade tumours (-0.41 ± 0.25 vs. -0.08 ± 0.34, P < 0.01). Other parameters did not differ significantly. ROC analysis demonstrated that correlation coefficient showed the best diagnostic performance for differentiating the two groups (AUC 0.79, sensitivity 96.0%, specificity 60%, accuracy 85.7%). SUV and ADC determined via PET/MR may be useful for differentiating between high-grade and low/intermediate-grade soft tissue tumours. • PET/MR allows voxel-based comparison of SUVs and ADCs in soft-tissue tumours. • A comprehensive assessment of internal heterogeneity was performed with scatter plots. • SUVmax or ADCminimum could not differentiate high-grade sarcoma from low/intermediate-grade tumours. • Only the correlation coefficient between SUV and ADC differentiated the two groups. • The correlation coefficient showed the best diagnostic performance by ROC analysis.

  17. [Ecological correlation between consumption of alcoholic beverages and liver cirrhosis mortality in Mexico].

    PubMed

    Narro-Robles, J; Gutiérrez-Avila, J H

    1997-01-01

    To determine the correlation between alcohol consumption and mortality from liver cirrhosis in Mexico. Analysis of the ecological correlation between the patterns of alcohol consumption determined by the National Addiction Survey in 1993 and mortality by liver cirrhosis, in the period between 1971-1993, in the eight regions in which the country was divided. To determine level of correlation, the Pearson and Spearman coefficients were calculated. Significant correlations were only found with the prevalence of spirits and pulque drinkers; with beer drinkers the correlation was negative. The correlation with pulque is interesting, since pulque consumption is considered to be low scale in some rural areas. The negative correlation with beer may indicate that beer drinking is nor a good indicator of alcoholism. Results, though limited to the possibilities of an ecological study, reveal the necessity of effective actions in the regions where spirits and pulque are consumed in excess.

  18. A new correlation coefficient for bivariate time-series data

    NASA Astrophysics Data System (ADS)

    Erdem, Orhan; Ceyhan, Elvan; Varli, Yusuf

    2014-11-01

    The correlation in time series has received considerable attention in the literature. Its use has attained an important role in the social sciences and finance. For example, pair trading in finance is concerned with the correlation between stock prices, returns, etc. In general, Pearson’s correlation coefficient is employed in these areas although it has many underlying assumptions which restrict its use. Here, we introduce a new correlation coefficient which takes into account the lag difference of data points. We investigate the properties of this new correlation coefficient. We demonstrate that it is more appropriate for showing the direction of the covariation of the two variables over time. We also compare the performance of the new correlation coefficient with Pearson’s correlation coefficient and Detrended Cross-Correlation Analysis (DCCA) via simulated examples.

  19. Active motion assisted by correlated stochastic torques.

    PubMed

    Weber, Christian; Radtke, Paul K; Schimansky-Geier, Lutz; Hänggi, Peter

    2011-07-01

    The stochastic dynamics of an active particle undergoing a constant speed and additionally driven by an overall fluctuating torque is investigated. The random torque forces are expressed by a stochastic differential equation for the angular dynamics of the particle determining the orientation of motion. In addition to a constant torque, the particle is supplemented by random torques, which are modeled as an Ornstein-Uhlenbeck process with given correlation time τ(c). These nonvanishing correlations cause a persistence of the particles' trajectories and a change of the effective spatial diffusion coefficient. We discuss the mean square displacement as a function of the correlation time and the noise intensity and detect a nonmonotonic dependence of the effective diffusion coefficient with respect to both correlation time and noise strength. A maximal diffusion behavior is obtained if the correlated angular noise straightens the curved trajectories, interrupted by small pirouettes, whereby the correlated noise amplifies a straightening of the curved trajectories caused by the constant torque.

  20. Exact Interval Estimation, Power Calculation, and Sample Size Determination in Normal Correlation Analysis

    ERIC Educational Resources Information Center

    Shieh, Gwowen

    2006-01-01

    This paper considers the problem of analysis of correlation coefficients from a multivariate normal population. A unified theorem is derived for the regression model with normally distributed explanatory variables and the general results are employed to provide useful expressions for the distributions of simple, multiple, and partial-multiple…

  1. Correlation of ultrasound estimated placental volume and umbilical cord blood volume in term pregnancy.

    PubMed

    Pannopnut, Papinwit; Kitporntheranunt, Maethaphan; Paritakul, Panwara; Kongsomboon, Kittipong

    2015-01-01

    To investigate the correlation between ultrasound measured placental volume and collected umbilical cord blood (UCB) volume in term pregnancy. An observational cross-sectional study of term singleton pregnant women in the labor ward at Maha Chakri Sirindhorn Medical Center was conducted. Placental thickness, height, and width were measured using two-dimensional (2D) ultrasound and calculated for placental volume using the volumetric mathematic model. After the delivery of the baby, UCB was collected and measured for its volume immediately. Then, birth weight, placental weight, and the actual placental volume were analyzed. The Pearson's correlation was used to determine the correlation between each two variables. A total of 35 pregnant women were eligible for the study. The mean and standard deviation of estimated placental volume and actual placental volume were 534±180 mL and 575±118 mL, respectively. The median UCB volume was 140 mL (range 98-220 mL). The UCB volume did not have a statistically significant correlation with the estimated placental volume (correlation coefficient 0.15; p=0.37). However, the UCB volume was significantly correlated with the actual placental volume (correlation coefficient 0.62; p<0.001) and birth weight (correlation coefficient 0.38; p=0.02). The estimated placental volume by 2D ultrasound was not significantly correlated with the UCB volume. Further studies to establish the correlation between the UCB volume and the estimated placental volume using other types of placental imaging may be needed.

  2. Clinical Relevance of Alternative Endpoints in Colorectal Cancer First-Line Therapy With Bevacizumab: A Retrospective Study.

    PubMed

    Turpin, Anthony; Paget-Bailly, Sophie; Ploquin, Anne; Hollebecque, Antoine; Peugniez, Charlotte; El-Hajbi, Farid; Bonnetain, Franck; Hebbar, Mohamed

    2018-03-01

    We studied the relationship between intermediate criteria and overall survival (OS) in metastatic colorectal cancer (mCRC) patients who received first-line chemotherapy with bevacizumab. We assessed OS, progression-free survival (PFS), duration of disease control (DDC), the sum of the periods in which the disease did not progress, and the time to failure of strategy (TFS), which was defined as the entire period before the introduction of a second-line treatment. Linear correlation and regression models were used, and Prentice criteria were investigated. With a median follow-up of 57.6 months for 216 patients, the median OS was 24.5 months (95% confidence interval [CI], 21.3-29.7). The median PFS, DDC, and TFS were 8.9 (95% CI, 8.4-9.7), 11.0 (95% CI, 9.8-12.4), and 11.1 (95% CI, 10.0-13.0) months, respectively. The correlations between OS and DDC (Pearson coefficient, 0.79 [95% CI, 0.73-0.83], determination coefficient, 0.62) and OS and TFS (Pearson coefficient, 0.79 [95% CI, 0.73-0.84], determination coefficient, 0.63) were satisfactory. Linear regression analysis showed a significant association between OS and DDC, and between OS and TFS. Prentice criteria were verified for TFS as well as DDC. DDC and TFS correlated with OS and are relevant as intermediate criteria in the setting of patients with mCRC treated with a first-line bevacizumab-based regimen. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Sorption of the monoterpenes α-pinene and limonene to carbonaceous geosorbents including biochar.

    PubMed

    Hale, Sarah E; Endo, Satoshi; Arp, Hans Peter H; Zimmerman, Andrew R; Cornelissen, Gerard

    2015-01-01

    The sorption of two monoterpenes, α pinene and limonene to the carbonaceous geosorbents graphite, bituminous coal, lignite coke, biochar and Pahokee peat was quantified. Polyethylene (PE) passive samplers were calibrated for the first time for these compounds by determining the PE-water partitioning coefficients and used as a tool to determine sorption to the carbonaceous geosorbents. Log KPE-water values were 3.49±0.58 for α pinene and 4.08±0.27 for limonene. The sorption of limonene to all materials was stronger than that for α pinene (differences of 0.2-1.3 log units between distribution coefficients for the monoterpenes). Placing Kd values in increasing order for α pinene gave biochar≈Pahokee peat≈bituminous coal≈lignite coke

  4. Study of morphological changes in scattering and optically anisotropic medium through correlation images

    NASA Astrophysics Data System (ADS)

    Jain, Neha; Shukla, Prashant; Singh, Jai

    2018-05-01

    Correlation images are very useful in determining the morphological changes. We have investigated the correlation image analysis on depolarization and retardance matrices of polystyrene and gelatine samples respectively. We observed that that correlation images have a potential to show a significant variation with change in the concentration of samples (polystyrene and gelatine). For polystyrene microspheres the correlation value decreases with increasing scattering coefficient. In gelatine samples the correlation also decreases with sample concentration. This variation in correlation for retardance shows the change in a birefringence property of gelatine solution.

  5. Estimation of water absorption coefficient using the TDR method

    NASA Astrophysics Data System (ADS)

    Suchorab, Zbigniew; Majerek, Dariusz; Brzyski, Przemysław; Sobczuk, Henryk; Raczkowski, Andrzej

    2017-07-01

    Moisture accumulation and transport in the building barriers is an important feature that influences building performance, causing serious exploitation problems as increased energy use, mold and bacteria growth, decrease of indoor air parameters that may lead to sick building syndrome (SBS). One of the parameters that is used to describe moisture characteristic of the material is water absorption coefficient being the measure of capillary behavior of the material as a function of time and the surface area of the specimen. As usual it is determined using gravimetric methods according to EN 1925:1999 standard. In this article we demonstrate the possibility of determination of water absorption coefficient of autoclaved aerated concrete (AAC) using the Time Domain Reflectometry (TDR) method. TDR is an electric technique that had been adopted from soil science and can be successfully used for real-time monitoring of moisture transport in building materials and envelopes. Data achieved using TDR readouts show high correlation with standard method of moisture absorptivity coefficient determination.

  6. A Correlation for Forced Convective Boiling Heat Transfer of Refrigerants in a Microfin Tube

    NASA Astrophysics Data System (ADS)

    Momoki, Satoru; Yu, Jian; Koyama, Shigeru; Fujii, Tetsu; Honda, Hiroshi

    The experimental study is reported on the forced convective boiling of pure refrigerants HCFC22, HFC134a and HCFC123 flowing in a horizontal microfin tube. The local heat transfer coefficient defined based on the actual inside surface area is measured in the ranges of mass velocity of 200 to 400 kg/m2s, heat flux of 5 to 64 kW/m2 and reduced pressure of 0.07 to 0.24. Using the Chen-type model, a new correlation for microfin tubes is proposed considering the enhancement effect of microfins on both the convective heat transfer and the nucleate boiling components. In the convective heat transfer component, the correlation to predict the heat transfer coefficient of liquid-only flow is determined from preliminary experiments on single-phase flow in microfin tubes, and the two-phase flow enhancement factor is determined from the present experimental data. For the nucleate boiling component, the correlation of Takamatsu et al. for smooth tube is modified. The prediction of the present correlation agrees well with present experimental data, and is available for several microfin tubes which were tested by other researchers.

  7. Genome-scale cluster analysis of replicated microarrays using shrinkage correlation coefficient.

    PubMed

    Yao, Jianchao; Chang, Chunqi; Salmi, Mari L; Hung, Yeung Sam; Loraine, Ann; Roux, Stanley J

    2008-06-18

    Currently, clustering with some form of correlation coefficient as the gene similarity metric has become a popular method for profiling genomic data. The Pearson correlation coefficient and the standard deviation (SD)-weighted correlation coefficient are the two most widely-used correlations as the similarity metrics in clustering microarray data. However, these two correlations are not optimal for analyzing replicated microarray data generated by most laboratories. An effective correlation coefficient is needed to provide statistically sufficient analysis of replicated microarray data. In this study, we describe a novel correlation coefficient, shrinkage correlation coefficient (SCC), that fully exploits the similarity between the replicated microarray experimental samples. The methodology considers both the number of replicates and the variance within each experimental group in clustering expression data, and provides a robust statistical estimation of the error of replicated microarray data. The value of SCC is revealed by its comparison with two other correlation coefficients that are currently the most widely-used (Pearson correlation coefficient and SD-weighted correlation coefficient) using statistical measures on both synthetic expression data as well as real gene expression data from Saccharomyces cerevisiae. Two leading clustering methods, hierarchical and k-means clustering were applied for the comparison. The comparison indicated that using SCC achieves better clustering performance. Applying SCC-based hierarchical clustering to the replicated microarray data obtained from germinating spores of the fern Ceratopteris richardii, we discovered two clusters of genes with shared expression patterns during spore germination. Functional analysis suggested that some of the genetic mechanisms that control germination in such diverse plant lineages as mosses and angiosperms are also conserved among ferns. This study shows that SCC is an alternative to the Pearson correlation coefficient and the SD-weighted correlation coefficient, and is particularly useful for clustering replicated microarray data. This computational approach should be generally useful for proteomic data or other high-throughput analysis methodology.

  8. [Determination of steviol in Stevia Rebaudiana leaves by near infrared spectroscopy].

    PubMed

    Tang, Qi-Kun; Wang, Yul; Wu, Yue-Jin; Min, Di; Chen, Da-Wei; Hu, Tong-Hua

    2014-10-01

    The objective of the present study is to develop a method for rapid determination of the content of stevioside (ST) and rebaudioside A (RA) in Stevia Rebaudiana leaves. One hundred and five samples of stevia from different areas containing ST of 0.27%-1.40% and RA of 0.61%-3.98% were used. The 105 groups' NIRS diagram was processed by different methods including subtracting a straight line (SLS), multiplicative scatter correction (MSC), first derivative (FD), second derivative (SD) and so on, and then all data were analyzed by partial least square (PLS). The study showed that SLS can be used to extracted spectra information thoroughly to analyze the contents of ST, the correlation coefficients of calibration (Re), the root-mean-square errors of calibration (RMSEC) and prediction (RMSEP), and the residual predictive deviation (RPD) were 0.986, 0.341, 1.00 and 2.8, respectively. The correlation coefficients of RA was 0.967, RMSEC was 1.50, RMSEP was 1.98 and RPD was 4.17. The results indicated that near infrared spectroscopy (NIRS) technique offers effective quantitative capability for ST and RA in Stevia Rebaudiana leaves. Then the model of stevia dried leaves was used to compare with the stevia powder near infrared model whose correlation coefficients of ST was 0.986, RMSEC was 0.32, RMSEP was 0.601 and RPD was 2.86 and the correlation coefficients of RA was 0.968, RMSEC was 1.50, RMSEP was 1.48 and RPD was 4.2. The result showed that there was no significant difference between the model of dried leaves and that of the powders. However, the dried leaves NIR model reduces the unnecessary the steps of drying and grinding in the actual detection process, saving the time and reducing the workload.

  9. Tests of Hypotheses Arising In the Correlated Random Coefficient Model*

    PubMed Central

    Heckman, James J.; Schmierer, Daniel

    2010-01-01

    This paper examines the correlated random coefficient model. It extends the analysis of Swamy (1971), who pioneered the uncorrelated random coefficient model in economics. We develop the properties of the correlated random coefficient model and derive a new representation of the variance of the instrumental variable estimator for that model. We develop tests of the validity of the correlated random coefficient model against the null hypothesis of the uncorrelated random coefficient model. PMID:21170148

  10. Latex agglutination inhibition card test for gentamicin assay: clinical evaluation and comparison with radioimmunoassay and bioassay.

    PubMed Central

    Standiford, H C; Bernstein, D; Nipper, H C; Caplan, E; Tatem, B; Hall, J S; Reynolds, J

    1981-01-01

    Gentamicin levels were determined in 100 serum specimens by a new latex agglutination inhibition card test, a radioimmunoassay (RIA), and a bioassay. Correlation coefficients determined by linear regression analysis demonstrated that the levels obtained by the latex agglutination inhibition card test had a high degree of correlation with the RIA and could be performed much faster and more economically when processing small numbers of specimens. The bioassay had a slightly lower degree of correlation with both the RIA and the latex test and was adversely influenced by concurrently administered antibiotics which could not be eliminated by beta-lactamase. When measuring gentamicin concentrations above 2 micrograms/ml, the coefficient of variation was less than 14% for the latex agglutination assay compared with 15% for the bioassay and 12% for RIA. The latex agglutination inhibition card test is a rapid, accurate, specific, and reproducible method for monitoring gentamicin levels in patients and is particularly applicable for laboratories processing small numbers of specimens. PMID:7247384

  11. Violent crime rates as a proxy for the social determinants of sexually transmissible infection rates: the consistent state-level correlation between violent crime and reported sexually transmissible infections in the United States, 1981-2010.

    PubMed

    Chesson, Harrell W; Owusu-Edusei, Kwame; Leichliter, Jami S; Aral, Sevgi O

    2013-11-01

    Numerous social determinants of health are associated with violent crime rates and sexually transmissible infection (STI) rates. This report aims to illustrate the potential usefulness of violent crime rates as a proxy for the social determinants of STI rates. For each year from 1981 to 2010, we assessed the strength of the association between the violent crime rate and the gonorrhoea (Neisseria gonorrhoeae) rate (number of total reported cases per 100?000) at the state level. Specifically, for each year, we calculated Pearson correlation coefficients (and P-values) between two variables (the violent crime rate and the natural log of the gonorrhoea rate) for all 50 states and Washington, DC. For comparison, we also examined the correlation between gonorrhoea rates, and rates of poverty and unemployment. We repeated the analysis using overall syphilis rates instead of overall gonorrhoea rates. The correlation between gonorrhoea and violent crime was significant at the P<0.001 level for every year from 1981 to 2010. Syphilis rates were also consistently correlated with violent crime rates. In contrast, the P-value for the correlation coefficient exceeded 0.05 in 9 of the 30 years for the association between gonorrhoea and poverty, and in 17 of the 30 years for that between gonorrhoea and unemployment. Because violent crime is associated with many social determinants of STIs and because it is consistently associated with STI rates, violent crime rates can be a useful proxy for the social determinants of health in statistical analyses of STI rates.

  12. Music therapy career aptitude and generalized self-efficacy in music therapy students.

    PubMed

    Lim, Hayoung A; Befi, Cathy M

    2014-01-01

    While the Music Therapy Career Aptitude Test (MTCAT) provides a measure of student aptitude, measures of perceived self-efficacy may provide additional information about a students' suitability for a music therapy career. As a first step in determining whether future studies examining combined scores from the MTCAT and the Generalized Self-Efficacy (GSE) scale would be useful to help predict academic success in music therapy, we explored the internal reliability of these two measures in a sample of undergraduate students, and the relationship (concurrent validity) of the measures to one another. Eighty undergraduate music therapy students (14 male; 66 female) completed the MTCAT and GSE. To determine internal reliability we conducted tests of normality and calculated Cronbach's Coefficient Alpha for each measure. Pearson correlation coefficients were calculated to ascertain the strength of the relationship between the MTCAT and GSE. MTCAT scores were normally distributed and had high internal consistency (Cronbach's α = 0.706). GSE scores were not normally distributed, but had high internal consistency (Cronbach's α = 0.748). The correlation coefficient analysis revealed that MTCAT and GSE scores were moderately correlated ((r = 0.426, p < 0.0001). MTCAT scores can be used to partially determine perceived self-efficacy in undergraduate music therapy students; however, a more complete picture of student suitability for music therapy may be determined by administering the GSE alongside the MTCAT. Future studies are needed to determine whether combined MTCAT and GSE scores can be used to predict student success in an undergraduate music therapy program. © the American Music Therapy Association 2014. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  13. The reliability and validity of a Japanese version of symptom checklist 90 revised

    PubMed Central

    Tomioka, Mitsunao; Shimura, Midori; Hidaka, Mikio; Kubo, Chiharu

    2008-01-01

    Objective To examine the validity and reliability of a Japanese version of the Symptom Checklist 90 Revised (SCL-90-R (J)). Methods The English SCL-90-R was translated to Japanese and the Japanese version confirmed by back-translation. To determine the factor validity and internal consistency of the nine primary subscales, 460 people from the community completed SCL-90-R(J). Test-retest reliability was examined for 104 outpatients and 124 healthy undergraduate students. The convergent-discriminant validity was determined for 80 inpatients who replied to both SCL-90-R(J) and the Minnesota Multiphasic Personality Inventory (MMPI). Results The correlation coefficients between the nine primary subscales and items were .26 to .78. Cronbach's alpha coefficients were from .76 (Phobic Anxiety) to .86 (Interpersonal Sensitivity). Pearson's correlation coefficients between test-retest scores were from .81 (Psychoticism) to .90 (Somatization) for the outpatients and were from .64 (Phobic Anxiety) to .78 (Paranoid Ideation) for the students. Each of the nine primary subscales correlated well with their corresponding constructs in the MMPI. Conclusion We confirmed the validity and reliability of SCL-90-R(J) for the measurement of individual distress. The nine primary subscales were consistent with the items of the original English version. PMID:18957078

  14. Relationship between hepatic CTGF expression and routine blood tests at the time of liver transplantation for biliary atresia: hope or hype for a biomarker of hepatic fibrosis.

    PubMed

    Haafiz, Allah; Farrington, Christian; Andres, Joel; Islam, Saleem

    2011-01-01

    Progressive hepatic fibrosis (HF) is a prominent feature of biliary atresia (BA), the most common indication for liver transplantation (LT) in children. Despite its importance in BA, HF is not evaluated in routine patient care because the invasiveness of liver biopsy makes histologic monitoring of fibrosis unfeasible. Therefore, the identification of noninvasive markers to assess HF is desirable especially in children. The main goal of this pilot project was to establish an investigational framework correlating hepatic expression of fibrogenic markers with routine blood tests in BA. Using liver explants from patients with BA (n = 26), immune-expression of connective tissue growth factor (CTGF), a key fibrogenic cytokine was determined using horseradish-labeled antibodies. Expression intensities of lobular (L-CTGF) and portal (P-CTGF) CTGF were determined by using ImageJ software. These CTGF intensities were correlated with blood tests performed at the time of LT. Correlation coefficients were determined for each blood test variable versus mean L-CTGF and P-CTGF expression intensities. A P-value of less than 0.05 was considered statistically significant. All patients had end-stage liver disease and persistent cholestasis at the time of LT. Kendall tau (τ) rank correlation coefficient for L-CTGF and white blood cell (WBC) was inversed (-0.52; P ≤ 0.02). Similar but statistically nonsignificant inverse relationships were noted between L-CTGF and prothrombin time (PT) (-0.15; P ≤ 0.4), international normalized ratio (INR) (-0.14; P ≤ 0.5), and platelet count (-0.36; P ≤ 0.09). Inversed (τ) rank correlation coefficients were also evident between P-CTGF expression and gamma-glutamyl transpeptidase (GGT), PT, INR, and platelet count. Pearson correlation coefficients for combinational analysis of standardized total bilirubin (TB), alkaline phosphatase, GGT, and platelet count with L-CTGF (0.33; P = 0.3) and P-CTGF (0.06; P = 0.8), were not significant. Similar analysis for alanine aminotransferase, TB, and GGT combination (L-CTGF, 0.16; P = 0.5; P-CTGF -0.3; P = 0.2) as well as WBC, platelet count, and TB (L-CTGF: -0.36; P = 0.09; P-CTGF -0.33; P = 0.13) also revealed nonsignificant results. Hepatic expression of fibrogenic markers can be correlated with routinely performed blood tests in patients with BA. We document that although a trend of inverse relationship is noted, hepatic CTGF expression does not correlate well with routinely performed blood tests in advanced BA. Further work is required to determine more reliable ways of noninvasive diagnosis of HF.

  15. Coolant-side heat-transfer rates for a hydrogen-oxygen rocket and a new technique for data correlation

    NASA Technical Reports Server (NTRS)

    Schacht, R. L.; Quentmeyer, R. J.

    1973-01-01

    An experimental investigation was conducted to determine the coolant-side, heat transfer coefficients for a liquid cooled, hydrogen-oxygen rocket thrust chamber. Heat transfer rates were determined from measurements of local hot gas wall temperature, local coolant temperature, and local coolant pressure. A correlation incorporating an integration technique for the transport properties needed near the pseudocritical temperature of liquid hydrogen gives a satisfactory prediction of hot gas wall temperatures.

  16. [Correlation analysis of major agronomic characters and the polysaccharide contents in Dendrobium officinale].

    PubMed

    Zhang, Lei; Zheng, Xi-Long; Qiu, Dao-Shou; Cai, Shi-Ke; Luo, Huan-Ming; Deng, Rui-Yun; Liu, Xiao-Jin

    2013-10-01

    In order to provide theoretical and technological basis for the germplasm innovation and variety breeding in Dendrobium officinale, a study of the correlation between polysaccharide content and agronomic characters was conducted. Based on the polysaccharide content determination and the agronomic characters investigation of 30 copies (110 individual plants) of Dendrobium officinale germplasm resources, the correlation between polysaccharide content and agronomic characters was analyzed via path and correlation analysis. Correlation analysis results showed that there was a significant negative correlation between average spacing and polysaccharide content, the correlation coefficient was -0.695. And the blade thickness was positively correlated with the polysaccharide content, but the correlation was not significant. The path analysis results showed that the stem length was the maximum influence factor to the polysaccharide, and it was positive effect, the direct path coefficient was 1.568. According to thess results, the polysaccharide content can be easily and intuitively estimated by the agronomic characters investigating data in the germpalsm resources screening and variety breeding. Therefore, it is a visual and practical technology guidance in quality variety breeding of Dendrobium officinale.

  17. Study of the anticorrelations between ozone and UV-B radiation using linear and exponential fits in Southern Brazil

    NASA Astrophysics Data System (ADS)

    Guarnieri, R.; Padilha, L.; Guarnieri, F.; Echer, E.; Makita, K.; Pinheiro, D.; Schuch, A.; Boeira, L.; Schuch, N.

    Ultraviolet radiation type B (UV-B 280-315nm) is well known by its damage to life on Earth, including the possibility of causing skin cancer in humans. However, the atmo- spheric ozone has absorption bands in this spectral radiation, reducing its incidence on Earth's surface. Therefore, the ozone amount is one of the parameters, besides clouds, aerosols, solar zenith angles, altitude, albedo, that determine the UV-B radia- tion intensity reaching the Earth's surface. The total ozone column, in Dobson Units, determined by TOMS spectrometer on board of a NASA satellite, and UV-B radiation measurements obtained by a UV-B radiometer model MS-210W (Eko Instruments) were correlated. The measurements were obtained at the Observatório Espacial do Sul - Instituto Nacional de Pesquisas Espaciais (OES/CRSPE/INPE-MCT) coordinates: Lat. 29.44oS, Long. 53.82oW. The correlations were made using UV-B measurements in fixed solar zenith angles and only days with clear sky were selected in a period from July 1999 to December 2001. Moreover, the mathematic behavior of correlation in dif- ferent angles was observed, and correlation coefficients were determined by linear and first order exponential fits. In both fits, high correlation coefficients values were ob- tained, and the difference between linear and exponential fit can be considered small.

  18. Effect of Atomic Charges on Octanol-Water Partition Coefficient Using Alchemical Free Energy Calculation.

    PubMed

    Ogata, Koji; Hatakeyama, Makoto; Nakamura, Shinichiro

    2018-02-15

    The octanol-water partition coefficient (log P ow ) is an important index for measuring solubility, membrane permeability, and bioavailability in the drug discovery field. In this paper, the log P ow values of 58 compounds were predicted by alchemical free energy calculation using molecular dynamics simulation. In free energy calculations, the atomic charges of the compounds are always fixed. However, they must be recalculated for each solvent. Therefore, three different sets of atomic charges were tested using quantum chemical calculations, taking into account vacuum, octanol, and water environments. The calculated atomic charges in the different environments do not necessarily influence the correlation between calculated and experimentally measured ∆ G water values. The largest correlation coefficient values of the solvation free energy in water and octanol were 0.93 and 0.90, respectively. On the other hand, the correlation coefficient of log P ow values calculated from free energies, the largest of which was 0.92, was sensitive to the combination of the solvation free energies calculated from the calculated atomic charges. These results reveal that the solvent assumed in the atomic charge calculation is an important factor determining the accuracy of predicted log P ow values.

  19. Intra- and Inter-rater Agreement of Superior Vena Cava Flow and Right Ventricular Outflow Measurements in Late Preterm and Term Neonates.

    PubMed

    Mahoney, Liam; Fernandez-Alvarez, Jose R; Rojas-Anaya, Hector; Aiton, Neil; Wertheim, David; Seddon, Paul; Rabe, Heike

    2018-02-24

    To explore the intra- and inter-rater agreement of superior vena cava (SVC) flow and right ventricular (RV) outflow in healthy and unwell late preterm neonates (33-37 weeks' gestational age), term neonates (≥37 weeks' gestational age), and neonates receiving total-body cooling. The intra- and inter-rater agreement (n = 25 and 41 neonates, respectively) rates for SVC flow and RV outflow were determined by echocardiography in healthy and unwell late preterm and term neonates with the use of Bland-Altman plots, the repeatability coefficient, the repeatability index, and intraclass correlation coefficients. The intra-rater repeatability index values were 41% for SVC flow and 31% for RV outflow, with intraclass correlation coefficients indicating good agreement for both measures. The inter-rater repeatability index values for SVC flow and RV outflow were 63% and 51%, respectively, with intraclass correlation coefficients indicating moderate agreement for both measures. If SVC flow or RV outflow is used in the hemodynamic treatment of neonates, sequential measurements should ideally be performed by the same clinician to reduce potential variability. © 2018 by the American Institute of Ultrasound in Medicine.

  20. Analysis of diffusion and binding in cells using the RICS approach.

    PubMed

    Digman, Michelle A; Gratton, Enrico

    2009-04-01

    The movement of macromolecules in cells is assumed to occur either through active transport or by diffusion. However, the determination of the diffusion coefficients in cells using fluctuation methods or FRAP frequently give diffusion coefficient that are orders of magnitude smaller than the diffusion coefficients measured for the same macromolecule in solution. It is assumed that the cell internal viscosity is partially responsible for this decrease in the apparent diffusion. When the apparent diffusion is too slow to be due to cytoplasm viscosity, it is assumed that weak binding of the macromolecules to immobile or quasi immobile structures is taking place. In this article, we derive equations for fitting of the RICS (Raster-scan Image Correlations Spectroscopy) data in cells to a model that includes transient binding to immobile structures, and we show that under some conditions, the spatio-temporal correlation provided by the RICS approach can distinguish the process of diffusion and weak binding. We apply the method to determine the diffusion in the cytoplasm and binding of Focal Adhesion Kinase-EGFP to adhesions in MEF cells.

  1. Research on maximum level noise contaminated of remote reference magnetotelluric measurements using synthesized data

    NASA Astrophysics Data System (ADS)

    Gang, Zhang; Fansong, Meng; Jianzhong, Wang; Mingtao, Ding

    2018-02-01

    Determining magnetotelluric impedance precisely and accurately is fundamental to valid inversion and geological interpretation. This study aims to determine the minimum value of signal-to-noise ratio (SNR) which maintains the effectiveness of remote reference technique. Results of standard time series simulation, addition of different Gaussian noises to obtain the different SNR time series, and analysis of the intermediate data, such as polarization direction, correlation coefficient, and impedance tensor, show that when the SNR value is larger than 23.5743, the polarization direction disorder at morphology and a smooth and accurate sounding carve value can be obtained. At this condition, the correlation coefficient value of nearly complete segments between the base and remote station is larger than 0.9, and impedance tensor Zxy presents only one aggregation, which meet the natural magnetotelluric signal characteristic.

  2. Modified Regression Correlation Coefficient for Poisson Regression Model

    NASA Astrophysics Data System (ADS)

    Kaengthong, Nattacha; Domthong, Uthumporn

    2017-09-01

    This study gives attention to indicators in predictive power of the Generalized Linear Model (GLM) which are widely used; however, often having some restrictions. We are interested in regression correlation coefficient for a Poisson regression model. This is a measure of predictive power, and defined by the relationship between the dependent variable (Y) and the expected value of the dependent variable given the independent variables [E(Y|X)] for the Poisson regression model. The dependent variable is distributed as Poisson. The purpose of this research was modifying regression correlation coefficient for Poisson regression model. We also compare the proposed modified regression correlation coefficient with the traditional regression correlation coefficient in the case of two or more independent variables, and having multicollinearity in independent variables. The result shows that the proposed regression correlation coefficient is better than the traditional regression correlation coefficient based on Bias and the Root Mean Square Error (RMSE).

  3. Determination of the Avogadro constant by the XRCD method using a 28Si-enriched sphere

    NASA Astrophysics Data System (ADS)

    Kuramoto, Naoki; Mizushima, Shigeki; Zhang, Lulu; Fujita, Kazuaki; Azuma, Yasushi; Kurokawa, Akira; Okubo, Sho; Inaba, Hajime; Fujii, Kenichi

    2017-10-01

    To determine the Avogadro constant N A by the x-ray crystal density method, the density of a 28Si-enriched crystal was determined by absolute measurements of the mass and volume of a 1 kg sphere manufactured from the crystal. The mass and volume were determined by an optical interferometer and a vacuum mass comparator, respectively. The sphere surface was characterized by x-ray photoelectron spectroscopy and spectroscopic ellipsometry to derive the mass and volume of the Si core of the sphere excluding the surface layers. From the mass and volume, the density of the Si core was determined with a relative standard uncertainty of 2.3  ×  10-8. By combining the Si core density with the lattice constant and the molar mass of the sphere reported by the International Avogadro Coordination (IAC) project in 2015, a new value of 6.022 140 84(15)  ×  1023 mol-1 was obtained for N A with a relative standard uncertainty of 2.4  ×  10-8. To make the N A value determined in this work usable for a future adjustment of the fundamental constants by the CODATA Task Group on Fundamental Constants, the correlation of the new N A value with the N A values determined in our previous works was examined. The correlation coefficients with the values of N A determined by IAC in 2011 and 2015 were estimated to be 0.07 and 0.28, respectively. The correlation of the new N A value with the N A value determined by IAC in 2017 using a different 28Si-enriched crystal was also examined, and the correlation coefficient was estimated to be 0.21.

  4. Clustering Coefficients for Correlation Networks.

    PubMed

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties.

  5. Clustering Coefficients for Correlation Networks

    PubMed Central

    Masuda, Naoki; Sakaki, Michiko; Ezaki, Takahiro; Watanabe, Takamitsu

    2018-01-01

    Graph theory is a useful tool for deciphering structural and functional networks of the brain on various spatial and temporal scales. The clustering coefficient quantifies the abundance of connected triangles in a network and is a major descriptive statistics of networks. For example, it finds an application in the assessment of small-worldness of brain networks, which is affected by attentional and cognitive conditions, age, psychiatric disorders and so forth. However, it remains unclear how the clustering coefficient should be measured in a correlation-based network, which is among major representations of brain networks. In the present article, we propose clustering coefficients tailored to correlation matrices. The key idea is to use three-way partial correlation or partial mutual information to measure the strength of the association between the two neighboring nodes of a focal node relative to the amount of pseudo-correlation expected from indirect paths between the nodes. Our method avoids the difficulties of previous applications of clustering coefficient (and other) measures in defining correlational networks, i.e., thresholding on the correlation value, discarding of negative correlation values, the pseudo-correlation problem and full partial correlation matrices whose estimation is computationally difficult. For proof of concept, we apply the proposed clustering coefficient measures to functional magnetic resonance imaging data obtained from healthy participants of various ages and compare them with conventional clustering coefficients. We show that the clustering coefficients decline with the age. The proposed clustering coefficients are more strongly correlated with age than the conventional ones are. We also show that the local variants of the proposed clustering coefficients (i.e., abundance of triangles around a focal node) are useful in characterizing individual nodes. In contrast, the conventional local clustering coefficients were strongly correlated with and therefore may be confounded by the node's connectivity. The proposed methods are expected to help us to understand clustering and lack thereof in correlational brain networks, such as those derived from functional time series and across-participant correlation in neuroanatomical properties. PMID:29599714

  6. Geologic and climatic controls on the radon emanation coefficient

    USGS Publications Warehouse

    Schumann, R.R.; Gundersen, L.C.S.; ,

    1997-01-01

    Geologic, pedologic, and climatic factors, including radium content, grain size, siting of radon parents within soil grains or on grain coatings, and soil moisture conditions, determine a soil's emanating power and radon transport characteristics. Data from field studies indicate that soils derived from similar parent rocks in different regions have significantly different emanation coefficients due to the effects of climate on these soil characteristics. An important tool for measuring radon source strength (i.e., radium content) is ground-based and aerial gamma radioactivity measurements. Regional correlations between soil radium content, determined by gamma spectrometry, and soil-gas or indoor radon concentrations can be traced to the influence of climatic and geologic factors on intrinsic permeability and radon emanation coefficients. Data on soil radium content, permeability, and moisture content, when combined with data on emanation coefficients, can form a framework for development of quantitative predictive models for radon generation in rocks and soils.

  7. Determination of blade-to-coolant heat-transfer coefficients on a forced-convection, water-cooled, single-stage turbine

    NASA Technical Reports Server (NTRS)

    Freche, John C; Schum, Eugene F

    1951-01-01

    Blade-to-coolant convective heat-transfer coefficients were obtained on a forced-convection water-cooled single-stage turbine over a large laminar flow range and over a portion of the transition range between laminar and turbulent flow. The convective coefficients were correlated by the general relation for forced-convection heat transfer with laminar flow. Natural-convection heat transfer was negligible for this turbine over the Grashof number range investigated. Comparison of turbine data with stationary tube data for the laminar flow of heated liquids showed good agreement. Calculated average midspan blade temperatures using theoretical gas-to-blade coefficients and blade-to-coolant coefficients from stationary-tube data resulted in close agreement with experimental data.

  8. Threshold network of a financial market using the P-value of correlation coefficients

    NASA Astrophysics Data System (ADS)

    Ha, Gyeong-Gyun; Lee, Jae Woo; Nobi, Ashadun

    2015-06-01

    Threshold methods in financial networks are important tools for obtaining important information about the financial state of a market. Previously, absolute thresholds of correlation coefficients have been used; however, they have no relation to the length of time. We assign a threshold value depending on the size of the time window by using the P-value concept of statistics. We construct a threshold network (TN) at the same threshold value for two different time window sizes in the Korean Composite Stock Price Index (KOSPI). We measure network properties, such as the edge density, clustering coefficient, assortativity coefficient, and modularity. We determine that a significant difference exists between the network properties of the two time windows at the same threshold, especially during crises. This implies that the market information depends on the length of the time window when constructing the TN. We apply the same technique to Standard and Poor's 500 (S&P500) and observe similar results.

  9. Translation, cross-cultural adaptation and validation of the Bulgarian version of the Dizziness Handicap Inventory.

    PubMed

    Georgieva-Zhostova, Spaska; Kolev, Ognyan I; Stambolieva, Katerina

    2014-09-01

    The aim of the present study was the translation, cross-cultural adaptation and validation of the Dizziness Handicap Inventory in Bulgarian language (DHI-BG). Ninety-seven vestibular patients (19 men and 78 women, mean age 45.08 ± 13.85 years) took part in the investigation. All participants were asked to fill in the DHI-BG. Internal consistency was estimated using Cronbach's alpha and item-total correlation, reproducibility by calculating Bland-Altman's limits of agreement and intraclass correlation coefficients (ICCs). Associations were estimated by Spearman's correlation coefficients. The Cronbach's alpha for the total score, functional, physical and emotional subscales of DHI-BG were 0.88, 0.75, 0.72 and 0.81. The floor and ceiling effects of the DHI-BG total scale were evaluated with respect to the limits of agreement which were ±9.4-14.53 points. Intraclass correlation coefficients (ICCs) for all scale and subscales were higher than the recommended value of 0.75 and determined good test-retest reliability. The range of items correlation for DHI-BG was from 0.27 (item 12) to 0.72 (item 3). No significant differences were observed in the Cronbach's alpha coefficients between the DHI-BG and the original version, the German and Italian versions of the questionnaire. The most significant difference was observed in comparison with the German version of DHI. Construct validity presented a moderate correlation between Romberg coefficients and DHI-BG scores and strong correlation between all scores of DHI and the self-perceived disability. The results suggest that DHI-BG scores show a good discriminative validity between groups with different levels of self-assessed disability. The Bulgarian version of the DHI is a reliable and valid tool in assessing the impact of dizziness on the quality of life in Bulgarian vestibular patients.

  10. Hyperspectral diffuse reflectance for determination of the optical properties of milk and fruit and vegetable juices

    NASA Astrophysics Data System (ADS)

    Qin, Jianwei; Lu, Renfu

    2005-11-01

    Absorption and reduced scattering coefficients are two fundamental optical properties for turbid biological materials. This paper presents the technique and method of using hyperspectral diffuse reflectance for fast determination of the optical properties of fruit and vegetable juices and milks. A hyperspectral imaging system was used to acquire spatially resolved steady-state diffuse reflectance over the spectral region between 530 and 900 nm from a variety of fruit and vegetable juices (citrus, grapefruit, orange, and vegetable) and milks with different fat levels (full, skim and mixed). The system collected diffuse reflectance in the source-detector separation range from 1.1 to 10.0 mm. The hyperspectral reflectance data were analyzed by using a diffusion theory model for semi-infinite homogeneous media. The absorption and reduced scattering coefficients of the fruit and vegetable juices and milks were extracted by inverse algorithms from the scattering profiles for wavelengths of 530-900 nm. Values of the absorption and reduced scattering coefficient at 650 nm were highly correlated to the fat content of the milk samples with the correlation coefficient of 0.990 and 0.989, respectively. The hyperspectral imaging technique can be extended to the measurement of other liquid and solid foods in which light scattering is dominant.

  11. Assessment of rate of drug release from oil vehicle using a rotating dialysis cell.

    PubMed

    Larsen, D H; Fredholt, K; Larsen, C

    2000-09-01

    The rate constants for transfer of model compounds (naproxen and lidocaine) from oily vehicle (Viscoleo) to aqueous buffer phases were determined by use of the rotating dialysis cell. Release studies were done for the partly ionized compounds at several pH values. A correlation between the overall first-order rate constant related to attainment of equilibrium, k(obs), and the pH-dependent distribution coefficient, D, determined between oil vehicle and aqueous buffer was established according to the equation: logk(obs)=-0.71 logD-0.22 (k(obs) in h(-1)). Based on this correlation it was suggested that the rate constant of a weak electrolyte at a specified D value could be considered equal to the k(obs) value for a non-electrolyte possessing a partition coefficient, P(app), the magnitude of which was equal to D. Specific rate constants k(ow) and k(wo) were calculated from the overall rate constant and the pH-dependent distribution coefficient. The rate constant representing the transport from oily vehicle to aqueous phase, k(ow), was found to be significantly influenced by the magnitude of the partition coefficient P(app) according to: logk(ow)=-0.71 logP(app)-log(P(app)+1)-0.22 (k(ow) in h(-1)).

  12. The minimal clinically important difference of the control of allergic rhinitis and asthma test (CARAT): cross-cultural validation and relation with pollen counts

    PubMed Central

    van der Leeuw, Sander; van der Molen, Thys; Dekhuijzen, PN Richard; Fonseca, Joao A; van Gemert, Frederik A; Gerth van Wijk, Roy; Kocks, Janwillem WH; Oosterom, Helma; Riemersma, Roland A; Tsiligianni, Ioanna G; de Weger, Letty A; Oude Elberink, Joanne NG; Flokstra-de Blok, Bertine MJ

    2015-01-01

    Background: The Control of Allergic Rhinitis and Asthma Test (CARAT) monitors control of asthma and allergic rhinitis. Aims: To determine the CARAT’s minimal clinically important difference (MCID) and to evaluate the psychometric properties of the Dutch CARAT. Methods: CARAT was applied in three measurements at 1-month intervals. Patients diagnosed with asthma and/or rhinitis were approached. MCID was evaluated using Global Rating of Change (GRC) and standard error of measurement (s.e.m.). Cronbach’s alpha was used to evaluate internal consistency. Spearman’s correlation coefficients were calculated between CARAT, the Asthma Control Questionnaire (ACQ5) and the Visual Analog Scale (VAS) on airway symptoms to determine construct and longitudinal validity. Test–retest reliability was evaluated with intra-class correlation coefficient (ICC). Changes in pollen counts were compared with delta CARAT and ACQ5 scores. Results: A total of 92 patients were included. The MCID of the CARAT was 3.50 based on GRC scores; the s.e.m. was 2.83. Cronbach’s alpha was 0.82. Correlation coefficients between CARAT and ACQ5 and VAS questions ranged from 0.64 to 0.76 (P<0.01). Longitudinally, correlation coefficients between delta CARAT scores and delta ACQ5 and VAS scores ranged from 0.41 to 0.67 (P<0.01). Test–retest reliability showed an ICC of 0.81 (P<0.01) and 0.80 (P<0.01). Correlations with pollen counts were higher for CARAT than for ACQ5. Conclusions: This is the first investigation of the MCID of the CARAT. The CARAT uses a whole-point scale, which suggests that the MCID is 4 points. The CARAT is a valid and reliable tool that is also applicable in the Dutch population. PMID:25569880

  13. Estimation of the biserial correlation and its sampling variance for use in meta-analysis.

    PubMed

    Jacobs, Perke; Viechtbauer, Wolfgang

    2017-06-01

    Meta-analyses are often used to synthesize the findings of studies examining the correlational relationship between two continuous variables. When only dichotomous measurements are available for one of the two variables, the biserial correlation coefficient can be used to estimate the product-moment correlation between the two underlying continuous variables. Unlike the point-biserial correlation coefficient, biserial correlation coefficients can therefore be integrated with product-moment correlation coefficients in the same meta-analysis. The present article describes the estimation of the biserial correlation coefficient for meta-analytic purposes and reports simulation results comparing different methods for estimating the coefficient's sampling variance. The findings indicate that commonly employed methods yield inconsistent estimates of the sampling variance across a broad range of research situations. In contrast, consistent estimates can be obtained using two methods that appear to be unknown in the meta-analytic literature. A variance-stabilizing transformation for the biserial correlation coefficient is described that allows for the construction of confidence intervals for individual coefficients with close to nominal coverage probabilities in most of the examined conditions. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Moving beyond quiet stance: applicability of the inverted pendulum model to stooping and crouching postures.

    PubMed

    Weaver, Tyler B; Glinka, Michal N; Laing, Andrew C

    2014-11-07

    Currently, it is unknown whether the inverted pendulum model is applicable to stooping or crouching postures. Therefore, the aim of this study was to determine the degree of applicability of the inverted pendulum model to these postures, via examination of the relationship between the centre of mass (COM) acceleration and centre of pressure (COP)-COM difference. Ten young adults held static standing, stooping and crouching postures, each for 20s. For both the anterior-posterior (AP) and medio-lateral (ML) directions, the time-varying COM acceleration and the COP-COM were computed, and the relationship between these two variables was determined using Pearson's correlation coefficients. Additionally, in both directions, the average absolute COM acceleration, average absolute COP-COM signal, and the inertial component (i.e., -I/Wh) were compared across postures. Pearson correlation coefficients revealed a significant negative relationship between the COM acceleration and COP-COM signal for all comparisons, regardless of the direction (p<0.001). While no effect of posture was observed in the AP direction (p=0.463), in the ML direction, the correlation coefficients for stooping were different (i.e., stronger) than standing (p=0.008). Regardless of direction, the average absolute COM acceleration for both the stooping and crouching postures was greater than standing (p<0.002). The high correlations indicate that the inverted pendulum model is applicable to stooping and crouching postures. Due to their importance in completing activities of daily living, there is merit in determining what type of motor strategies are used to control such postures and whether these strategies change with age. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  15. Interaction of finger enslaving and error compensation in multiple finger force production.

    PubMed

    Martin, Joel R; Latash, Mark L; Zatsiorsky, Vladimir M

    2009-01-01

    Previous studies have documented two patterns of finger interaction during multi-finger pressing tasks, enslaving and error compensation, which do not agree with each other. Enslaving is characterized by positive correlation between instructed (master) and non-instructed (slave) finger(s) while error compensation can be described as a pattern of negative correlation between master and slave fingers. We hypothesize that pattern of finger interaction, enslaving or compensation depends on the initial force level and the magnitude of the targeted force change. Subjects were instructed to press with four fingers (I index, M middle, R ring, and L little) from a specified initial force to target forces following a ramp target line. Force-force relations between master and each of three slave fingers were analyzed during the ramp phase of trials by calculating correlation coefficients within each master-slave pair and then two-factor ANOVA was performed to determine effect of initial force and force increase on the correlation coefficients. It was found that, as initial force increased, the value of the correlation coefficient decreased and in some cases became negative, i.e. the enslaving transformed into error compensation. Force increase magnitude had a smaller effect on the correlation coefficients. The observations support the hypothesis that the pattern of inter-finger interaction--enslaving or compensation--depends on the initial force level and, to a smaller degree, on the targeted magnitude of the force increase. They suggest that the controller views tasks with higher steady-state forces and smaller force changes as implying a requirement to avoid large changes in the total force.

  16. On the role of structure-dynamic relationship in determining the excess entropy of mixing and chemical ordering in binary square-well liquid alloys

    NASA Astrophysics Data System (ADS)

    Lalneihpuii, R.; Shrivastava, Ruchi; Mishra, Raj Kumar

    2018-05-01

    Using statistical mechanical model with square-well (SW) interatomic potential within the frame work of mean spherical approximation, we determine the composition dependent microscopic correlation functions, interdiffusion coefficients, surface tension and chemical ordering in Ag-Cu melts. Further Dzugutov universal scaling law of normalized diffusion is verified with SW potential in binary mixtures. We find that the excess entropy scaling law is valid for SW binary melts. The partial and total structure factors in the attractive and repulsive regions of the interacting potential are evaluated and then Fourier transformed to get partial and total radial distribution functions. A good agreement between theoretical and experimental values for total structure factor and the reduced radial distribution function are observed, which consolidates our model calculations. The well-known Bhatia-Thornton correlation functions are also computed for Ag-Cu melts. The concentration-concentration correlations in the long wavelength limit in liquid Ag-Cu alloys have been analytically derived through the long wavelength limit of partial correlation functions and apply it to demonstrate the chemical ordering and interdiffusion coefficients in binary liquid alloys. We also investigate the concentration dependent viscosity coefficients and surface tension using the computed diffusion data in these alloys. Our computed results for structure, transport and surface properties of liquid Ag-Cu alloys obtained with square-well interatomic interaction are fully consistent with their corresponding experimental values.

  17. Estimation of the simple correlation coefficient.

    PubMed

    Shieh, Gwowen

    2010-11-01

    This article investigates some unfamiliar properties of the Pearson product-moment correlation coefficient for the estimation of simple correlation coefficient. Although Pearson's r is biased, except for limited situations, and the minimum variance unbiased estimator has been proposed in the literature, researchers routinely employ the sample correlation coefficient in their practical applications, because of its simplicity and popularity. In order to support such practice, this study examines the mean squared errors of r and several prominent formulas. The results reveal specific situations in which the sample correlation coefficient performs better than the unbiased and nearly unbiased estimators, facilitating recommendation of r as an effect size index for the strength of linear association between two variables. In addition, related issues of estimating the squared simple correlation coefficient are also considered.

  18. Body Adiposity Index Performance in Estimating Body Fat Percentage in Colombian College Students: Findings from the FUPRECOL-Adults Study.

    PubMed

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio

    2017-01-17

    Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5)) -18 ) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin's concordance correlation coefficient, linear regression, Bland-Altman's agreement analysis, concordance correlation coefficient ( ρc ) and the coefficient of determination ( R ²) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R ² = 0.384, p < 0.001. A paired-sample t -test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = -6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin's concordance correlation coefficient was poor ( ρc = 0.014, 95% CI = -0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels.

  19. Characterizing air quality data from complex network perspective.

    PubMed

    Fan, Xinghua; Wang, Li; Xu, Huihui; Li, Shasha; Tian, Lixin

    2016-02-01

    Air quality depends mainly on changes in emission of pollutants and their precursors. Understanding its characteristics is the key to predicting and controlling air quality. In this study, complex networks were built to analyze topological characteristics of air quality data by correlation coefficient method. Firstly, PM2.5 (particulate matter with aerodynamic diameter less than 2.5 μm) indexes of eight monitoring sites in Beijing were selected as samples from January 2013 to December 2014. Secondly, the C-C method was applied to determine the structure of phase space. Points in the reconstructed phase space were considered to be nodes of the network mapped. Then, edges were determined by nodes having the correlation greater than a critical threshold. Three properties of the constructed networks, degree distribution, clustering coefficient, and modularity, were used to determine the optimal value of the critical threshold. Finally, by analyzing and comparing topological properties, we pointed out that similarities and difference in the constructed complex networks revealed influence factors and their different roles on real air quality system.

  20. Anomaly detection of flight routes through optimal waypoint

    NASA Astrophysics Data System (ADS)

    Pusadan, M. Y.; Buliali, J. L.; Ginardi, R. V. H.

    2017-01-01

    Deciding factor of flight, one of them is the flight route. Flight route determined by coordinate (latitude and longitude). flight routed is determined by its coordinates (latitude and longitude) as defined is waypoint. anomaly occurs, if the aircraft is flying outside the specified waypoint area. In the case of flight data, anomalies occur by identifying problems of the flight route based on data ADS-B. This study has an aim of to determine the optimal waypoints of the flight route. The proposed methods: i) Agglomerative Hierarchical Clustering (AHC) in several segments based on range area coordinates (latitude and longitude) in every waypoint; ii) The coefficient cophenetics correlation (c) to determine the correlation between the members in each cluster; iii) cubic spline interpolation as a graphic representation of the has connected between the coordinates on every waypoint; and iv). Euclidean distance to measure distances between waypoints with 2 centroid result of clustering AHC. The experiment results are value of coefficient cophenetics correlation (c): 0,691≤ c ≤ 0974, five segments the generated of the range area waypoint coordinates, and the shortest and longest distance between the centroid with waypoint are 0.46 and 2.18. Thus, concluded that the shortest distance is used as the reference coordinates of optimal waypoint, and farthest distance can be indicated potentially detected anomaly.

  1. Quantitative correlations between collision induced dissociation mass spectrometry coupled with electrospray ionization or atmospheric pressure chemical ionization mass spectrometry - Experiment and theory

    NASA Astrophysics Data System (ADS)

    Ivanova, Bojidarka; Spiteller, Michael

    2018-04-01

    The problematic that we consider in this paper treats the quantitative correlation model equations between experimental kinetic and thermodynamic parameters of coupled electrospray ionization (ESI) mass spectrometry (MS) or atmospheric pressure chemical ionization (APCI) mass spectrometry with collision induced dissociation mass spectrometry, accounting for the fact that the physical phenomena and mechanisms of ESI- and APCI-ion formation are completely different. There are described forty two fragment reactions of three analytes under independent ESI- and APCI-measurements. The developed new quantitative models allow us to study correlatively the reaction kinetics and thermodynamics using the methods of mass spectrometry, which complementary application with the methods of the quantum chemistry provide 3D structural information of the analytes. Both static and dynamic quantum chemical computations are carried out. The object of analyses are [2,3-dimethyl-4-(4-methyl-benzoyl)-2,3-di-p-tolyl-cyclobutyl]-p-tolyl-methanone (1) and the polycyclic aromatic hydrocarbons derivatives of dibenzoperylen (2) and tetrabenzo [a,c,fg,op]naphthacene (3), respectively. As far as (1) is known to be a product of [2π+2π] cycloaddition reactions of chalcone (1,3-di-p-tolyl-propenone), however producing cyclic derivatives with different stereo selectivity, so that the study provide crucial data about the capability of mass spectrometry to provide determine the stereo selectivity of the analytes. This work also first provides quantitative treatment of the relations '3D molecular/electronic structures'-'quantum chemical diffusion coefficient'-'mass spectrometric diffusion coefficient', thus extending the capability of the mass spectrometry for determination of the exact 3D structure of the analytes using independent measurements and computations of the diffusion coefficients. The determination of the experimental diffusion parameters is carried out within the 'current monitoring method' evaluating the translation diffusion of charged analytes, while the theoretical modelling of MS ions and computations of theoretical diffusion coefficients are based on the Arrhenius type behavior of the charged species under ESI- and APCI-conditions. Although the study provide certain sound considerations for the quantitative relations between the reaction kinetic-thermodynamics and 3D structure of the analytes together with correlations between 3D molecular/electronic structures-quantum chemical diffusion coefficient-mass spectrometric diffusion coefficient, which contribute significantly to the structural analytical chemistry, the results have importance to other areas such as organic synthesis and catalysis as well.

  2. The relationship between coefficient of restitution and state of charge of zinc alkaline primary LR6 batteries [Bouncing alkaline batteries: A basic solution

    DOE PAGES

    Bhadra, S.; Hertzberg, B. J.; Croft, M.; ...

    2015-03-13

    The coefficient of restitution of alkaline batteries had been shown to increase as a function of depth of discharge. In this work, using non-destructive mechanical testing, the change in coefficient of restitution is compared to in situ energy-dispersive x-ray diffraction data to determine the cause of the macroscopic change in coefficient of restitution. The increase in coefficient of restitution correlates to the formation of a percolation pathway of ZnO within the anode of the cell, and that the coefficient of restitution saturates at a value of 0.63 ± .05 at 50% state if charge when the anode has densified intomore » porous ZnO solid. Of note is the sensitivity of coefficient of restitution to the amount of ZnO formation that rivals the sensitivity on in situ energy-dispersive x-ray diffraction spectroscopy.« less

  3. The Attenuation of Correlation Coefficients: A Statistical Literacy Issue

    ERIC Educational Resources Information Center

    Trafimow, David

    2016-01-01

    Much of the science reported in the media depends on correlation coefficients. But the size of correlation coefficients depends, in part, on the reliability with which the correlated variables are measured. Understanding this is a statistical literacy issue.

  4. The Correlation of Active and Passive Microwave Outputs for the Skylab S-193 Sensor

    NASA Technical Reports Server (NTRS)

    Krishen, K.

    1976-01-01

    This paper presents the results of the correlation analysis of the Skylab S-193 13.9 GHz Radiometer/Scatterometer data. Computer analysis of the S-193 data shows more than 50 percent of the radiometer and scatterometer data are uncorrelated. The correlation coefficients computed for the data gathered over various ground scenes indicates the desirability of using both active and passive sensors for the determination of various Earth phenomena.

  5. An agreement coefficient for image comparison

    USGS Publications Warehouse

    Ji, Lei; Gallo, Kevin

    2006-01-01

    Combination of datasets acquired from different sensor systems is necessary to construct a long time-series dataset for remotely sensed land-surface variables. Assessment of the agreement of the data derived from various sources is an important issue in understanding the data continuity through the time-series. Some traditional measures, including correlation coefficient, coefficient of determination, mean absolute error, and root mean square error, are not always optimal for evaluating the data agreement. For this reason, we developed a new agreement coefficient for comparing two different images. The agreement coefficient has the following properties: non-dimensional, bounded, symmetric, and distinguishable between systematic and unsystematic differences. The paper provides examples of agreement analyses for hypothetical data and actual remotely sensed data. The results demonstrate that the agreement coefficient does include the above properties, and therefore is a useful tool for image comparison.

  6. Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity

    PubMed Central

    Wilson, Walter B.; Sander, Lane C.; Oña-Ruales, Jorge O.; Mössner, Stephanie G.; Sidisky, Leonard M.; Lee, Milton L.; Wise, Stephen A.

    2017-01-01

    Retention indices for 48 polycyclic aromatic sulfur heterocycles (PASHs) were determined using gas chromatography with three different stationary phases: a 50% phenyl phase, a 50% liquid crystalline dimethylpolysiloxane (LC-DMPS) phase, and an ionic liquid (IL) phase. Correlations between the retention behavior on the three stationary phases and PASH geometry (L/B and T, i.e., length-to-breadth ratio and thickness, respectively) were investigated for the following four isomer sets: (1) 4 three-ring molecular mass (MM) 184 Da PASHs, (2) 13 four-ring MM 234 Da PASHs, (3) 10 five-ring MM 258 Da PASHs, and (4) 20 five-ring MM 284 Da PASHs. Correlation coefficients for retention on the 50% LC-DMPS vs L/B ranged from r = 0.50 (MM 284 Da) to r = 0.77 (MM 234 Da). Correlation coefficients for retention on the IL phase vs L/B ranged from r = 0.31 (MM 234 Da) to r = 0.54 (MM 284 Da). Correlation coefficients for retention on the 50% phenyl vs L/B ranged from r = 0.14 (MM 258 Da) to r = 0.59 (MM 284 Da). Several correlation trends are discussed in detail for the retention behavior of PASH on the three stationary phases. PMID:28089272

  7. Retention behavior of isomeric polycyclic aromatic sulfur heterocycles in gas chromatography on stationary phases of different selectivity.

    PubMed

    Wilson, Walter B; Sander, Lane C; Oña-Ruales, Jorge O; Mössner, Stephanie G; Sidisky, Leonard M; Lee, Milton L; Wise, Stephen A

    2017-02-17

    Retention indices for 48 polycyclic aromatic sulfur heterocycles (PASHs) were determined using gas chromatography with three different stationary phases: a 50% phenyl phase, a 50% liquid crystalline dimethylpolysiloxane (LC-DMPS) phase, and an ionic liquid (IL) phase. Correlations between the retention behavior on the three stationary phases and PASH geometry (L/B and T, i.e., length-to-breadth ratio and thickness, respectively) were investigated for the following four isomer sets: (1) 4 three-ring molecular mass (MM) 184Da PASHs, (2) 13 four-ring MM 234Da PASHs, (3) 10 five-ring MM 258Da PASHs, and (4) 20 five-ring MM 284Da PASHs. Correlation coefficients for retention on the 50% LC-DMPS vs L/B ranged from r=0.50 (MM 284Da) to r=0.77 (MM 234Da). Correlation coefficients for retention on the IL phase vs L/B ranged from r=0.31 (MM 234Da) to r=0.54 (MM 284Da). Correlation coefficients for retention on the 50% phenyl vs L/B ranged from r=0.14 (MM 258Da) to r=0.59 (MM 284Da). Several correlation trends are discussed in detail for the retention behavior of PASH on the three stationary phases. Published by Elsevier B.V.

  8. Retention behavior of alkyl-substituted polycyclic aromatic sulfur heterocycle isomers in gas chromatography on stationary phases of different selectivity.

    PubMed

    Wilson, Walter B; Sander, Lane C; Oña-Ruales, Jorge O; Mössner, Stephanie G; Sidisky, Leonard M; Lee, Milton L; Wise, Stephen A

    2017-02-10

    Retention indices for 10 sets of alkyl-substituted polycyclic aromatic sulfur heterocycles (PASHs) isomers (total of 80 PASHs) were determined using gas chromatography with three different stationary phases: a 50% phenyl phase, a 50% liquid crystalline dimethylpolysiloxane (LC-DMPS) phase, and an ionic liquid (IL) phase. Correlations between the retention behavior on the three stationary phases and PASH geometry [length-to-breadth (L/B) and thickness (T)] were investigated for the following PASHs: 4 methyl-substituted dibenzothiophenes (DBTs), 3 ethyl-substituted DBTs, 15 dimethyl-substituted DBTs, 8 trimethyl-substituted DBTs, 15 methyl-substituted naphthothiophenes, 30 methyl-substituted benzonaphthothiophenes, and 5 methyl-substituted tetrapheno[1,12-bcd]thiophene. Correlation coefficients for retention on the 50% phenyl phase vs L/B ranged from r=-0.28 (MeBbN23Ts) to r=0.92 (EtDBTs). Correlation coefficients for retention on the IL phase vs L/B ranged from r=0.13 (MeN12Ts) to r=0.83 (EtDBTs). Correlation coefficients for retention on the 50% LC-DMPS phase vs L/B ranged from r=0.22 (MeDBTs) to r=0.84 (TriMeDBTs). Published by Elsevier B.V.

  9. The Relationship between Teacher Self-Efficacy and Student Discipline Referrals Written by Secondary Teachers from a Rural School District in a Southern State

    ERIC Educational Resources Information Center

    Laughter, Edwin Brice

    2017-01-01

    The purpose of this quantitative correlational study was to determine the strength of the relationship between teacher self-efficacy and discipline referrals. Participants completed the Teachers' Sense of Efficacy Scale, which was used as an operational definition of teacher self-efficacy. A Spearman's correlation coefficient measured the…

  10. Description and Evaluation of the 2009–2010 Pennsylvania Influenza Sentinel School Monitoring System

    PubMed Central

    Marriott, Chandra K.; Ostroff, Stephen; Waller, Kirsten

    2011-01-01

    Objectives. We described and evaluated the 2009–2010 Pennsylvania Influenza Sentinel School Monitoring System, a voluntary sentinel network of schools that report data on school absenteeism and visits to the school nurse for influenza-like illness (ILI). Methods. Participating schools provided daily absenteeism and ILI data on a weekly basis through an online survey. We used participation and weekly response rates to determine acceptability, timeliness, and simplicity. We assessed representativeness by comparing participating schools with nonparticipating schools. We compared monitoring system data with statewide reports of laboratory-confirmed influenza. Results. Of the 3244 Pennsylvania public schools, 367 (11%) enrolled in the system. On average, 79% of enrolled schools completed the survey each week. Although the peak week of elevated absenteeism coincided with the peak of statewide laboratory-confirmed influenza cases, the correlation between absenteeism and state data was nonsignificant (correlation coefficient = 0.10; P = .56). Trends in ILI correlated significantly with state data (correlation coefficient = 0.67; P < .001). Conclusions. The school-based sentinel system is a simple, acceptable, reliable device for tracking absenteeism and ILI in schools. Further analyses are necessary to determine the comparative value of this system and other influenza surveillance systems. PMID:21566024

  11. Estimated Accuracy of Three Common Trajectory Statistical Methods

    NASA Technical Reports Server (NTRS)

    Kabashnikov, Vitaliy P.; Chaikovsky, Anatoli P.; Kucsera, Tom L.; Metelskaya, Natalia S.

    2011-01-01

    Three well-known trajectory statistical methods (TSMs), namely concentration field (CF), concentration weighted trajectory (CWT), and potential source contribution function (PSCF) methods were tested using known sources and artificially generated data sets to determine the ability of TSMs to reproduce spatial distribution of the sources. In the works by other authors, the accuracy of the trajectory statistical methods was estimated for particular species and at specified receptor locations. We have obtained a more general statistical estimation of the accuracy of source reconstruction and have found optimum conditions to reconstruct source distributions of atmospheric trace substances. Only virtual pollutants of the primary type were considered. In real world experiments, TSMs are intended for application to a priori unknown sources. Therefore, the accuracy of TSMs has to be tested with all possible spatial distributions of sources. An ensemble of geographical distributions of virtual sources was generated. Spearman s rank order correlation coefficient between spatial distributions of the known virtual and the reconstructed sources was taken to be a quantitative measure of the accuracy. Statistical estimates of the mean correlation coefficient and a range of the most probable values of correlation coefficients were obtained. All the TSMs that were considered here showed similar close results. The maximum of the ratio of the mean correlation to the width of the correlation interval containing the most probable correlation values determines the optimum conditions for reconstruction. An optimal geographical domain roughly coincides with the area supplying most of the substance to the receptor. The optimal domain s size is dependent on the substance decay time. Under optimum reconstruction conditions, the mean correlation coefficients can reach 0.70 0.75. The boundaries of the interval with the most probable correlation values are 0.6 0.9 for the decay time of 240 h and 0.5 0.95 for the decay time of 12 h. The best results of source reconstruction can be expected for the trace substances with a decay time on the order of several days. Although the methods considered in this paper do not guarantee high accuracy they are computationally simple and fast. Using the TSMs in optimum conditions and taking into account the range of uncertainties, one can obtain a first hint on potential source areas.

  12. Investigation of Particle Sampling Bias in the Shear Flow Field Downstream of a Backward Facing Step

    NASA Technical Reports Server (NTRS)

    Meyers, James F.; Kjelgaard, Scott O.; Hepner, Timothy E.

    1990-01-01

    The flow field about a backward facing step was investigated to determine the characteristics of particle sampling bias in the various flow phenomena. The investigation used the calculation of the velocity:data rate correlation coefficient as a measure of statistical dependence and thus the degree of velocity bias. While the investigation found negligible dependence within the free stream region, increased dependence was found within the boundary and shear layers. Full classic correction techniques over-compensated the data since the dependence was weak, even in the boundary layer and shear regions. The paper emphasizes the necessity to determine the degree of particle sampling bias for each measurement ensemble and not use generalized assumptions to correct the data. Further, it recommends the calculation of the velocity:data rate correlation coefficient become a standard statistical calculation in the analysis of all laser velocimeter data.

  13. Identification of Correlated GRACE Monthly Harmonic Coefficients Using Pattern Recognition and Neural Networks

    NASA Astrophysics Data System (ADS)

    Piretzidis, D.; Sra, G.; Sideris, M. G.

    2016-12-01

    This study explores new methods for identifying correlation errors in harmonic coefficients derived from monthly solutions of the Gravity Recovery and Climate Experiment (GRACE) satellite mission using pattern recognition and neural network algorithms. These correlation errors are evidenced in the differences between monthly solutions and can be suppressed using a de-correlation filter. In all studies so far, the implementation of the de-correlation filter starts from a specific minimum order (i.e., 11 for RL04 and 38 for RL05) until the maximum order of the monthly solution examined. This implementation method has two disadvantages, namely, the omission of filtering correlated coefficients of order less than the minimum order and the filtering of uncorrelated coefficients of order higher than the minimum order. In the first case, the filtered solution is not completely free of correlated errors, whereas the second case results in a monthly solution that suffers from loss of geophysical signal. In the present study, a new method of implementing the de-correlation filter is suggested, by identifying and filtering only the coefficients that show indications of high correlation. Several numerical and geometric properties of the harmonic coefficient series of all orders are examined. Extreme cases of both correlated and uncorrelated coefficients are selected, and their corresponding properties are used to train a two-layer feed-forward neural network. The objective of the neural network is to identify and quantify the correlation by providing the probability of an order of coefficients to be correlated. Results show good performance of the neural network, both in the validation stage of the training procedure and in the subsequent use of the trained network to classify independent coefficients. The neural network is also capable of identifying correlated coefficients even when a small number of training samples and neurons are used (e.g.,100 and 10, respectively).

  14. The feasibility of measuring joint angular velocity with a gyro-sensor.

    PubMed

    Arai, Takeshi; Obuchi, Shuichi; Shiba, Yoshitaka; Omuro, Kazuya; Nakano, Chika; Higashi, Takuya

    2008-01-01

    To determine the reliability of an assessment of joint angular velocity using a gyro-sensor and to examine the relationship between ankle angular velocity and physical functions. Cross-sectional. Kinesiology laboratory. Twenty healthy young adults (mean age, 22.5 y) and 113 community-dwelling older adults (mean age, 75.1 y). Not applicable. Maximal ankle joint velocity was measured using a gyro-sensor during heel-rising and jumping with knee extended. The intraclass correlation coefficient (ICC) was used to determine the intertester and intratester reliability. The Pearson correlation coefficient was used to examine the relationships between maximal ankle joint velocity and isometric muscle strength and isokinetic muscle power in young adults and also to examine the relationships between maximal ankle joint velocity and functional performance measurements such as walking time in older adults. High reliability was found for intertester (ICC=.96) and intratester reliability (ICC=.96). The data from the gyro-sensor highly correlated with muscle strength (r range, .62-.68; P<.01) and muscle power (r range, .45-.79; P range, .01-.05). In older subjects, mobility functions significantly correlated with the angular velocity of ankle plantarflexion. Measurement of ankle angular velocity using a gyro-sensor is both reliable and feasible, with the results representing a significant correlation to muscle power and performance measurements.

  15. The Association Between Self-Rated Fitness and Cardiorespiratory Fitness in Adults.

    PubMed

    Jensen, Karina Gregersen; Rosthøj, Susanne; Linneberg, Allan; Aadahl, Mette

    2018-06-01

    To assess criterion validity of a single item question on self-rated physical fitness against objectively measured cardiorespiratory fitness. From the Health2008 study 749 men and women between 30 and 60 years of age rated their fitness as excellent, very good, good, fair or poor. Cardiorespiratory fitness was estimated with the watt-max test. Agreement between self-rated and objectively measured physical fitness was assessed by Cohen's weighted kappa coefficient. Correlation was determined by Goodman & Kruskal's gamma correlation coefficient. All analyses were stratified according to gender. Data from 323 men and 426 women were analysed. There was a slight agreement between self-rated and objectively measured fitness in men (weighted kappa: 0.18, [95%CI: 0.13;0.23]) and a fair agreement in women (weighted kappa: 0.27, [95%CI: 0.22;0.32]). In both genders, self-rated fitness was positively correlated with objectively measured fitness (moderate correlation; gamma correlation coefficient for men: 0.63 [95%CI: 0.54;0.72] and women: 0.67 [95%CI: 0.59;0.75]). There was a slight to fair agreement and moderate, positive correlations between self-rated physical fitness and watt-max estimated cardiorespiratory fitness. Hence, a single-item question on physical fitness may be a cost-effective method of assessing fitness in large population studies, but is not valid for individual assessments. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Comparison of nanoparticle diffusion using fluorescence correlation spectroscopy and differential dynamic microscopy within concentrated polymer solutions

    NASA Astrophysics Data System (ADS)

    Shokeen, Namita; Issa, Christopher; Mukhopadhyay, Ashis

    2017-12-01

    We studied the diffusion of nanoparticles (NPs) within aqueous entangled solutions of polyethylene oxide (PEO) by using two different optical techniques. Fluorescence correlation spectroscopy, a method widely used to investigate nanoparticle dynamics in polymer solution, was used to measure the long-time diffusion coefficient (D) of 25 nm radius particles within high molecular weight, Mw = 600 kg/mol PEO in water solutions. Differential dynamic microscopy (DDM) was used to determine the wave-vector dependent dynamics of NPs within the same polymer solutions. Our results showed good agreement between the two methods, including demonstration of normal diffusion and almost identical diffusion coefficients obtained by both techniques. The research extends the scope of DDM to study the dynamics and rheological properties of soft matter at a nanoscale. The measured diffusion coefficients followed a scaling theory, which can be explained by the coupling between polymer dynamics and NP motion.

  17. The Determination of Soil-plant Transfer Coefficients of Cesium-137 and Other Elements by γ-Ray Measurement and PIXE Analysis, for use in the Remediation of Fukushima

    NASA Astrophysics Data System (ADS)

    Ishii, K.; Fujita, A.; Toyama, S.; Terakawa, A.; Matsuyama, S.; Arai, H.; Osada, N.; Takyu, S.; Matsuyama, T.; Koshio, S.; Watanabe, K.; Ito, S.; Kasahara, K.

    Edible wild plants growing in the area around the Fukushima Daiichi nuclear power plant remain contaminated. It is important to identify plants with low levels of contamination for the restoration of agriculture in the area. We collected specimens of 10 wild plant species growing in Iitate village which is one of the most highly contaminated areas and also sampled the soil beneath each plant. We measured the specific activity of 137Cs and the concentrations of Na, Mg, Al, Si, P, S, K, Ca, Fe, Zn, Rb and Sr in these samples using a germanium detector and PIXE analysis, respectively. We compared the soil-plant transfer coefficient of 137Cs with those of each element and determined their correlation with 137Cs. It was found that a low Sr transfer coefficient could be used to determine the plants with a low 137Cs transfer coefficient. We suggest that PIXE analysis is a useful analysis technique for agricultural remediation projects in highly contaminated areas around the Fukushima Daiichi nuclear power plant.

  18. Correlation between the signal-to-noise ratio improvement factor (KSNR) and clinical image quality for chest imaging with a computed radiography system

    NASA Astrophysics Data System (ADS)

    Moore, C. S.; Wood, T. J.; Saunderson, J. R.; Beavis, A. W.

    2015-12-01

    This work assessed the appropriateness of the signal-to-noise ratio improvement factor (KSNR) as a metric for the optimisation of computed radiography (CR) of the chest. The results of a previous study in which four experienced image evaluators graded computer simulated chest images using a visual grading analysis scoring (VGAS) scheme to quantify the benefit of using an anti-scatter grid were used for the clinical image quality measurement (number of simulated patients  =  80). The KSNR was used to calculate the improvement in physical image quality measured in a physical chest phantom. KSNR correlation with VGAS was assessed as a function of chest region (lung, spine and diaphragm/retrodiaphragm), and as a function of x-ray tube voltage in a given chest region. The correlation of the latter was determined by the Pearson correlation coefficient. VGAS and KSNR image quality metrics demonstrated no correlation in the lung region but did show correlation in the spine and diaphragm/retrodiaphragmatic regions. However, there was no correlation as a function of tube voltage in any region; a Pearson correlation coefficient (R) of  -0.93 (p  =  0.015) was found for lung, a coefficient (R) of  -0.95 (p  =  0.46) was found for spine, and a coefficient (R) of  -0.85 (p  =  0.015) was found for diaphragm. All demonstrate strong negative correlations indicating conflicting results, i.e. KSNR increases with tube voltage but VGAS decreases. Medical physicists should use the KSNR metric with caution when assessing any potential improvement in clinical chest image quality when introducing an anti-scatter grid for CR imaging, especially in the lung region. This metric may also be a limited descriptor of clinical chest image quality as a function of tube voltage when a grid is used routinely.

  19. Using the manual ability classification system in young adults with cerebral palsy and normal intelligence.

    PubMed

    van Meeteren, Jetty; Nieuwenhuijsen, Channah; de Grund, Arthur; Stam, Henk J; Roebroeck, Marij E

    2010-01-01

    The study aimed to establish whether the manual ability classification system (MACS), a valid classification system for manual ability in children with cerebral palsy (CP), is applicable in young adults with CP and normal intelligence. The participants (n = 83) were young adults with CP and normal intelligence and had a mean age of 19.9 years. In this study, inter observer reliability of the MACS was determined. We investigated relationships between the MACS level and patient characteristics (such as the gross motor function classification system (GMFCS) level, limb distribution of the spastic paresis and educational level) and with functional activities of the upper extremity (assessed with the Melbourne assessment, the Abilhand questionnaire and the domain self-care of the functional independence measure (FIM)). Furthermore, with a linear regression analysis it was determined whether the MACS is a significant determinant of activity limitations and participation restrictions. The reliability was good (intraclass correlation coefficient 0.83). The Spearman correlation coefficients with GMFCS level, limb distribution of the spastic paresis and educational level were 0.53, 0.46, and 0.26, respectively. MACS level correlated moderately with outcome measures of functional activities (correlations ranging from -0.38 to -0.55). MACS level is, in addition to the GMFCS level, an important determinant for limitations in activities and restrictions in participation. We conclude that the MACS is a feasible method to classify manual ability in young adults with CP and normal intelligence with a good manual ability.

  20. [Health expenditures, income inequality, and the marginalization index in Mexico's health system].

    PubMed

    Pinzón Florez, Carlos Eduardo; Reveiz, Ludovic; Idrovo, Alvaro J; Reyes Morales, Hortensia

    2014-01-01

    Evaluate the effect of the relationship among public health expenditures, income inequality, and the marginalization index on maternal and child mortality in Mexico, to determine the effect of these factors on health system performance from a technical efficiency perspective. An ecological study of 32 Mexican states. Correlations were estimated between maternal and infant mortality and public health expenditures in total per capita, federal per capita, and state per capita for the years 2000, 2005, and 2010 (Gini coefficient and marginalization index). Linear regressions were used to explore the association of these variables with health indicators in the state systems. Negative correlations were observed for the marginalization index and Gini coefficient with regard to life expectancy at birth (-0.62 and -0.28 respectively). Furthermore, there was a positive correlation of 0.59 between the marginalization index and infant mortality (P <0.05). Multiple linear regression models revealed a negative effect of the marginalization index and Gini coefficient on health out-comes. Federal funding had a positive effect on system performance in terms of health indicators. Health system reform in Mexico has had a positive impact on the country's health indicators; federal financial investment seems to be effective in this regard. Social determinants have an important effect on health system performance, and analysis using multisectoral and multidisciplinary approaches are needed in addressing them.

  1. Tmax Determined Using a Bayesian Estimation Deconvolution Algorithm Applied to Bolus Tracking Perfusion Imaging: A Digital Phantom Validation Study.

    PubMed

    Uwano, Ikuko; Sasaki, Makoto; Kudo, Kohsuke; Boutelier, Timothé; Kameda, Hiroyuki; Mori, Futoshi; Yamashita, Fumio

    2017-01-10

    The Bayesian estimation algorithm improves the precision of bolus tracking perfusion imaging. However, this algorithm cannot directly calculate Tmax, the time scale widely used to identify ischemic penumbra, because Tmax is a non-physiological, artificial index that reflects the tracer arrival delay (TD) and other parameters. We calculated Tmax from the TD and mean transit time (MTT) obtained by the Bayesian algorithm and determined its accuracy in comparison with Tmax obtained by singular value decomposition (SVD) algorithms. The TD and MTT maps were generated by the Bayesian algorithm applied to digital phantoms with time-concentration curves that reflected a range of values for various perfusion metrics using a global arterial input function. Tmax was calculated from the TD and MTT using constants obtained by a linear least-squares fit to Tmax obtained from the two SVD algorithms that showed the best benchmarks in a previous study. Correlations between the Tmax values obtained by the Bayesian and SVD methods were examined. The Bayesian algorithm yielded accurate TD and MTT values relative to the true values of the digital phantom. Tmax calculated from the TD and MTT values with the least-squares fit constants showed excellent correlation (Pearson's correlation coefficient = 0.99) and agreement (intraclass correlation coefficient = 0.99) with Tmax obtained from SVD algorithms. Quantitative analyses of Tmax values calculated from Bayesian-estimation algorithm-derived TD and MTT from a digital phantom correlated and agreed well with Tmax values determined using SVD algorithms.

  2. Correlation of porous and functional properties of food materials by NMR relaxometry and multivariate analysis.

    PubMed

    Haiduc, Adrian Marius; van Duynhoven, John

    2005-02-01

    The porous properties of food materials are known to determine important macroscopic parameters such as water-holding capacity and texture. In conventional approaches, understanding is built from a long process of establishing macrostructure-property relations in a rational manner. Only recently, multivariate approaches were introduced for the same purpose. The model systems used here are oil-in-water emulsions, stabilised by protein, and form complex structures, consisting of fat droplets dispersed in a porous protein phase. NMR time-domain decay curves were recorded for emulsions with varied levels of fat, protein and water. Hardness, dry matter content and water drainage were determined by classical means and analysed for correlation with the NMR data with multivariate techniques. Partial least squares can calibrate and predict these properties directly from the continuous NMR exponential decays and yields regression coefficients higher than 82%. However, the calibration coefficients themselves belong to the continuous exponential domain and do little to explain the connection between NMR data and emulsion properties. Transformation of the NMR decays into a discreet domain with non-negative least squares permits the use of multilinear regression (MLR) on the resulting amplitudes as predictors and hardness or water drainage as responses. The MLR coefficients show that hardness is highly correlated with the components that have T2 distributions of about 20 and 200 ms whereas water drainage is correlated with components that have T2 distributions around 400 and 1800 ms. These T2 distributions very likely correlate with water populations present in pores with different sizes and/or wall mobility. The results for the emulsions studied demonstrate that NMR time-domain decays can be employed to predict properties and to provide insight in the underlying microstructural features.

  3. Simulation data for an estimation of the maximum theoretical value and confidence interval for the correlation coefficient.

    PubMed

    Rocco, Paolo; Cilurzo, Francesco; Minghetti, Paola; Vistoli, Giulio; Pedretti, Alessandro

    2017-10-01

    The data presented in this article are related to the article titled "Molecular Dynamics as a tool for in silico screening of skin permeability" (Rocco et al., 2017) [1]. Knowledge of the confidence interval and maximum theoretical value of the correlation coefficient r can prove useful to estimate the reliability of developed predictive models, in particular when there is great variability in compiled experimental datasets. In this Data in Brief article, data from purposely designed numerical simulations are presented to show how much the maximum r value is worsened by increasing the data uncertainty. The corresponding confidence interval of r is determined by using the Fisher r → Z transform.

  4. Ischemic lesion volume determination on diffusion weighted images vs. apparent diffusion coefficient maps.

    PubMed

    Bråtane, Bernt Tore; Bastan, Birgul; Fisher, Marc; Bouley, James; Henninger, Nils

    2009-07-07

    Though diffusion weighted imaging (DWI) is frequently used for identifying the ischemic lesion in focal cerebral ischemia, the understanding of spatiotemporal evolution patterns observed with different analysis methods remains imprecise. DWI and calculated apparent diffusion coefficient (ADC) maps were serially obtained in rat stroke models (MCAO): permanent, 90 min, and 180 min temporary MCAO. Lesion volumes were analyzed in a blinded and randomized manner by 2 investigators using (i) a previously validated ADC threshold, (ii) visual determination of hypointense regions on ADC maps, and (iii) visual determination of hyperintense regions on DWI. Lesion volumes were correlated with 24 hour 2,3,5-triphenyltetrazoliumchloride (TTC)-derived infarct volumes. TTC-derived infarct volumes were not significantly different from the ADC and DWI-derived lesion volumes at the last imaging time points except for significantly smaller DWI lesions in the pMCAO model (p=0.02). Volumetric calculation based on TTC-derived infarct also correlated significantly stronger to volumetric calculation based on last imaging time point derived lesions on ADC maps than DWI (p<0.05). Following reperfusion, lesion volumes on the ADC maps significantly reduced but no change was observed on DWI. Visually determined lesion volumes on ADC maps and DWI by both investigators correlated significantly with threshold-derived lesion volumes on ADC maps with the former method demonstrating a stronger correlation. There was also a better interrater agreement for ADC map analysis than for DWI analysis. Ischemic lesion determination by ADC was more accurate in final infarct prediction, rater independent, and provided exclusive information on ischemic lesion reversibility.

  5. Determinants of ocular deviation in esotropic subjects under general anesthesia.

    PubMed

    Daien, Vincent; Turpin, Chloé; Lignereux, François; Belghobsi, Riadh; Le Meur, Guylene; Lebranchu, Pierre; Pechereau, Alain

    2013-01-01

    The authors attempted to identify the determinants of ocular deviation in a population of patients with esotropia under general anesthesia. Forty-one patients with esotropia were included. Horizontal ocular deviation was evaluated by the photographic Hirschberg test both in the awakened state and under general anesthesia before surgery. Changes in ocular deviation were measured and a multivariate analysis was used to assess its clinical determinants. The mean age (± standard deviation [SD]) of study subjects was 13 ± 11 years and 51% were females. The mean spherical equivalent refraction of the right eye was 2.44 ± 2.50 diopters (D), with no significant difference between eyes (P = .26). The mean ocular deviation changed significantly, from 33.5 ± 12.5 prism diopters (PD) at preoperative examination to 8.8 ± 11.4 PD under general anesthesia (P = .0001). The changes in ocular deviation positively correlated with the pre-operative ocular deviation (correlation coefficient r = 0.59, P = .0001) and negatively correlated with patient age (correlation coefficient r = -0.53, P = .0001). These two determinants remained significant after multivariate adjustment of the following variables: preoperative ocular deviation; age; gender; spherical equivalent refraction; and number of previous strabismus surgeries (model r(2) = 0.49, P = .0001). The ocular position under general anesthesia was reported as a key factor in the surgical treatment of subjects with esotropia; therefore, its clinical determinants were assessed. The authors observed that preoperative ocular deviation and patient age were the main factors that influenced the ocular position under general anesthesia. Copyright 2013, SLACK Incorporated.

  6. A 3D analysis of oxygen transfer in a low-cost micro-bioreactor for animal cell suspension culture.

    PubMed

    Yu, P; Lee, T S; Zeng, Y; Low, H T

    2007-01-01

    A 3D numerical model was developed to study the flow field and oxygen transport in a micro-bioreactor with a rotating magnetic bar on the bottom to mix the culture medium. The Reynolds number (Re) was kept in the range of 100-716 to ensure laminar environment for animal cell culture. The volumetric oxygen transfer coefficient (k(L)a) was determined from the oxygen concentration distribution. It was found that the effect of the cell consumption on k(L)a could be negligible. A correlation was proposed to predict the liquid-phase oxygen transfer coefficient (k(Lm)) as a function of Re. The overall oxygen transfer coefficient (k(L)) was obtained by the two-resistance model. Another correlation, within an error of 15%, was proposed to estimate the minimum oxygen concentration to avoid cell hypoxia. By combination of the correlations, the maximum cell density, which the present micro-bioreactor could support, was predicted to be in the order of 10(12) cells m(-3). The results are comparable with typical values reported for animal cell growth in mechanically stirred bioreactors.

  7. Diagnosing cysts with correlation coefficient images from 2-dimensional freehand elastography.

    PubMed

    Booi, Rebecca C; Carson, Paul L; O'Donnell, Matthew; Richards, Michael S; Rubin, Jonathan M

    2007-09-01

    We compared the diagnostic potential of using correlation coefficient images versus elastograms from 2-dimensional (2D) freehand elastography to characterize breast cysts. In this preliminary study, which was approved by the Institutional Review Board and compliant with the Health Insurance Portability and Accountability Act, we imaged 4 consecutive human subjects (4 cysts, 1 biopsy-verified benign breast parenchyma) with freehand 2D elastography. Data were processed offline with conventional 2D phase-sensitive speckle-tracking algorithms. The correlation coefficient in the cyst and surrounding tissue was calculated, and appearances of the cysts in the correlation coefficient images and elastograms were compared. The correlation coefficient in the cysts was considerably lower (14%-37%) than in the surrounding tissue because of the lack of sufficient speckle in the cysts, as well as the prominence of random noise, reverberations, and clutter, which decorrelated quickly. Thus, the cysts were visible in all correlation coefficient images. In contrast, the elastograms associated with these cysts each had different elastographic patterns. The solid mass in this study did not have the same high decorrelation rate as the cysts, having a correlation coefficient only 2.1% lower than that of surrounding tissue. Correlation coefficient images may produce a more direct, reliable, and consistent method for characterizing cysts than elastograms.

  8. Heat transfer and pressure drop of condensation of hydrocarbons in tubes

    NASA Astrophysics Data System (ADS)

    Fries, Simon; Skusa, Severin; Luke, Andrea

    2018-03-01

    The heat transfer coefficient and pressure drop are investigated for propane. Two different mild steel plain tubes and saturation pressures are considered for varying mass flux and vapour quality. The pressure drop is compared to the Friedel-Correlation with two different approaches to determine the friction factor. The first is calculation as proposed by Friedel and the second is through single phase pressure drop investigations. For lower vapour qualities the experimental results are in better agreement with the approach of the calculated friction factor. For higher vapour qualities the experimental friction factor is more precise. The pressure drop increases for a decreasing tube diameter and saturation pressure. The circumferential temperature profile and heat transfer coefficients are shown for a constant vapour quality at varying mass fluxes. The subcooling is highest for the bottom of the tube and lowest for the top. The average subcooling as well as the circumferential deviation decreases for rising mass fluxes. The averaged heat transfer coefficients are compared to the model proposed by Thome and Cavallini. The experimental results are in good agreement with both correlations, however the trend is better described with the correlation from Thome. The experimental heat transfer coefficients are under predicted by Thome and over predicted by Cavallini.

  9. Repeatability and reproducibility of corneal thickness using SOCT Copernicus HR.

    PubMed

    Vidal, Silvia; Viqueira, Valentín; Mas, David; Domenech, Begoña

    2013-05-01

    The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (S(W)) and the within-subject coefficient of variation (C(W)). The level of agreement by Bland-Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.

  10. Preliminary study of radioactive limonite localities in Colorado, Utah, and Wyoming

    USGS Publications Warehouse

    Lovering, T.G.; Beroni, E.P.

    1956-01-01

    Nine radioactive limonite localities of different types were sampled during the spring and fall of 1953 in an effort to establish criteria for differentiating limonite outcrops associated with uranium or thorium deposits from limonite outcrops not associated with such deposits. The samples were analyzed for uranium and thorium by standard chemical methods, for equivalent uranium by the radiometric method, and for a number of common metals by semiquantitative geochemical methods. Correlation coefficients were then calculated for each of the metals with respect to equivalent uranium, and to uranium where present, for all of the samples from each locality. The correlation coefficients may indicate a significant association between uranium or thorium and certain metals. Occurrences of specific that are interpreted as significant very considerably for different uranium localities but are more consistent for the thorium localities. Samples taken from radioactive outcrops in the vicinity of uranium or thorium deposits can be quickly analyzed by geochemical methods for various elements. Correlation coefficients can then be determined for the various elements with respect to uranium or thorium; if any significant correlations are obtained, the elements showing such correlation may be indicators of uranium or thorium. Soil samples of covered areas in the vicinity of the radioactive outcrop may then be analyzed for the indicator elements and any resulting anomalies used as a guide for prospecting where the depth of overburden is too great to allow the use of radiation-detecting instruments. Correlation coefficients of the associated indicator elements, used in conjunction with petrographic evidence, may also be useful in interpreting the origin and paragenesis of radioactive deposits. Changes in color of limonite stains on the outcrop may also be a useful guide to ore in some areas.

  11. Assessment of a solid-phase reagent for urinary specific gravity determination.

    PubMed

    Chu, S Y; Sparks, D

    1984-02-01

    We have compared the specific gravity (S.G.) determined by the N-Multistix method with that obtained from the Total Solids (TS) meter. Overall, 88.7% of the specific gravity results obtained with the reagent strip method were within 0.005 of those obtained with the TS meter. There was a good correlation between the methods and there was no bias for the group means obtained by either method. A good correlation was also found between the S.G. on the strip and osmolality (correlation coefficient of 0.955). The results obtained with the reagent strip for urinary specific gravity therefore appear acceptable for routine laboratory purposes.

  12. Validity and reliability of an adapted Thai version of Scoliosis Research Society-22 questionnaire for adolescent idiopathic scoliosis.

    PubMed

    Sathira-Angkura, Vera; Pithankuakul, Kongkit; Sakulpipatana, Susana; Piyaskulkaew, Chaiwat; Kunakornsawat, Sombat

    2012-04-20

    Cross-sectional observational study to investigate psychometric properties of an adapted Thai version of the refined Scoliosis Research Society-22 (SRS-22) questionnaire. To evaluate the reliability and validity of the adapted Thai version of the refined SRS-22 questionnaire. The SRS-22 questionnaire is a valid instrument for assessing the health-related quality of life for patients with adolescent idiopathic scoliosis. Recently, the questionnaire has been translated and validated in many languages for non-English-speaking countries. Translation/retranslation of the English version of the SRS-22 was conducted, and the cross-cultural adaptation process was performed. The Thai version SRS-22 and previously validated Thai version Short-Form survey version 2.0 (SF-36V2) questionnaires were administered to 77 patients with adolescent idiopathic scoliosis who had surgical treatment. Fifty-eight patients (52 adolescent girls) had filled out the first set of questionnaires. Thirty patients of the first-time responders completed the second set of questionnaires. The mean age at the time of operation was 14.6 years and the mean age at the time of the final follow-up was 18.7 years. The mean preoperative scoliosis curve magnitude was 55.4° (range, 30°-95°) and postoperative curve magnitude was 20.1° (range, 0°-60°). Internal consistency was determined with Cronbach α coefficient. Intraclass correlation coefficient was used for test-retest reliability. Concurrent validity was evaluated by comparing SRS-22 domains with relevant domains in the SF-36V2 questionnaire, using the Pearson correlation coefficient. The mean overall Cronbach α coefficient of the adapted Thai version SRS-22 was 0.76. The 2 of corresponding domains (mental health = 0.80 and self-image = 0.83) had satisfactory internal consistency and the remaining domains (pain = 0.78; function/activity = 0.74; and satisfaction = 0.76) were good. The intraclass correlation coefficient for 5 domains was ranged from 0.79 to 0.90, which demonstrated the satisfactory test/retest reproducibility. The concurrent validity, determined by the Pearson correlation coefficient between SRS-22 and SF-36V2 domains, had a good correlation for 15 relevant comparisons (r = 0.50-0.75). The adapted Thai version of the SRS-22 questionnaire had validity and reliability, which can be used to assess the outcome of treatment among Thai-speaking patients with adolescent idiopathic scoliosis.

  13. Quantifying Abdominal Adipose Tissue and Thigh Muscle Volume and Hepatic Proton Density Fat Fraction: Repeatability and Accuracy of an MR Imaging-based, Semiautomated Analysis Method.

    PubMed

    Middleton, Michael S; Haufe, William; Hooker, Jonathan; Borga, Magnus; Dahlqvist Leinhard, Olof; Romu, Thobias; Tunón, Patrik; Hamilton, Gavin; Wolfson, Tanya; Gamst, Anthony; Loomba, Rohit; Sirlin, Claude B

    2017-05-01

    Purpose To determine the repeatability and accuracy of a commercially available magnetic resonance (MR) imaging-based, semiautomated method to quantify abdominal adipose tissue and thigh muscle volume and hepatic proton density fat fraction (PDFF). Materials and Methods This prospective study was institutional review board- approved and HIPAA compliant. All subjects provided written informed consent. Inclusion criteria were age of 18 years or older and willingness to participate. The exclusion criterion was contraindication to MR imaging. Three-dimensional T1-weighted dual-echo body-coil images were acquired three times. Source images were reconstructed to generate water and calibrated fat images. Abdominal adipose tissue and thigh muscle were segmented, and their volumes were estimated by using a semiautomated method and, as a reference standard, a manual method. Hepatic PDFF was estimated by using a confounder-corrected chemical shift-encoded MR imaging method with hybrid complex-magnitude reconstruction and, as a reference standard, MR spectroscopy. Tissue volume and hepatic PDFF intra- and interexamination repeatability were assessed by using intraclass correlation and coefficient of variation analysis. Tissue volume and hepatic PDFF accuracy were assessed by means of linear regression with the respective reference standards. Results Adipose and thigh muscle tissue volumes of 20 subjects (18 women; age range, 25-76 years; body mass index range, 19.3-43.9 kg/m 2 ) were estimated by using the semiautomated method. Intra- and interexamination intraclass correlation coefficients were 0.996-0.998 and coefficients of variation were 1.5%-3.6%. For hepatic MR imaging PDFF, intra- and interexamination intraclass correlation coefficients were greater than or equal to 0.994 and coefficients of variation were less than or equal to 7.3%. In the regression analyses of manual versus semiautomated volume and spectroscopy versus MR imaging, PDFF slopes and intercepts were close to the identity line, and correlations of determination at multivariate analysis (R 2 ) ranged from 0.744 to 0.994. Conclusion This MR imaging-based, semiautomated method provides high repeatability and accuracy for estimating abdominal adipose tissue and thigh muscle volumes and hepatic PDFF. © RSNA, 2017.

  14. A New Methodology of Spatial Cross-Correlation Analysis

    PubMed Central

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran’s index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson’s correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China’s urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes. PMID:25993120

  15. A new methodology of spatial cross-correlation analysis.

    PubMed

    Chen, Yanguang

    2015-01-01

    Spatial correlation modeling comprises both spatial autocorrelation and spatial cross-correlation processes. The spatial autocorrelation theory has been well-developed. It is necessary to advance the method of spatial cross-correlation analysis to supplement the autocorrelation analysis. This paper presents a set of models and analytical procedures for spatial cross-correlation analysis. By analogy with Moran's index newly expressed in a spatial quadratic form, a theoretical framework is derived for geographical cross-correlation modeling. First, two sets of spatial cross-correlation coefficients are defined, including a global spatial cross-correlation coefficient and local spatial cross-correlation coefficients. Second, a pair of scatterplots of spatial cross-correlation is proposed, and the plots can be used to visually reveal the causality behind spatial systems. Based on the global cross-correlation coefficient, Pearson's correlation coefficient can be decomposed into two parts: direct correlation (partial correlation) and indirect correlation (spatial cross-correlation). As an example, the methodology is applied to the relationships between China's urbanization and economic development to illustrate how to model spatial cross-correlation phenomena. This study is an introduction to developing the theory of spatial cross-correlation, and future geographical spatial analysis might benefit from these models and indexes.

  16. Predicting enteric methane emission of dairy cows with milk Fourier-transform infrared spectra and gas chromatography-based milk fatty acid profiles.

    PubMed

    van Gastelen, S; Mollenhorst, H; Antunes-Fernandes, E C; Hettinga, K A; van Burgsteden, G G; Dijkstra, J; Rademaker, J L W

    2018-06-01

    The objective of the present study was to compare the prediction potential of milk Fourier-transform infrared spectroscopy (FTIR) for CH 4 emissions of dairy cows with that of gas chromatography (GC)-based milk fatty acids (MFA). Data from 9 experiments with lactating Holstein-Friesian cows, with a total of 30 dietary treatments and 218 observations, were used. Methane emissions were measured for 3 consecutive days in climate respiration chambers and expressed as production (g/d), yield (g/kg of dry matter intake; DMI), and intensity (g/kg of fat- and protein-corrected milk; FPCM). Dry matter intake was 16.3 ± 2.18 kg/d (mean ± standard deviation), FPCM yield was 25.9 ± 5.06 kg/d, CH 4 production was 366 ± 53.9 g/d, CH 4 yield was 22.5 ± 2.10 g/kg of DMI, and CH 4 intensity was 14.4 ± 2.58 g/kg of FPCM. Milk was sampled during the same days and analyzed by GC and by FTIR. Multivariate GC-determined MFA-based and FTIR-based CH 4 prediction models were developed, and subsequently, the final CH 4 prediction models were evaluated with root mean squared error of prediction and concordance correlation coefficient analysis. Further, we performed a random 10-fold cross validation to calculate the performance parameters of the models (e.g., the coefficient of determination of cross validation). The final GC-determined MFA-based CH 4 prediction models estimate CH 4 production, yield, and intensity with a root mean squared error of prediction of 35.7 g/d, 1.6 g/kg of DMI, and 1.6 g/kg of FPCM and with a concordance correlation coefficient of 0.72, 0.59, and 0.77, respectively. The final FTIR-based CH 4 prediction models estimate CH 4 production, yield, and intensity with a root mean squared error of prediction of 43.2 g/d, 1.9 g/kg of DMI, and 1.7 g/kg of FPCM and with a concordance correlation coefficient of 0.52, 0.40, and 0.72, respectively. The GC-determined MFA-based prediction models described a greater part of the observed variation in CH 4 emission than did the FTIR-based models. The cross validation results indicate that all CH 4 prediction models (both GC-determined MFA-based and FTIR-based models) are robust; the difference between the coefficient of determination and the coefficient of determination of cross validation ranged from 0.01 to 0.07. The results indicate that GC-determined MFA have a greater potential than FTIR spectra to estimate CH 4 production, yield, and intensity. Both techniques hold potential but may not yet be ready to predict CH 4 emission of dairy cows in practice. Additional CH 4 measurements are needed to improve the accuracy and robustness of GC-determined MFA and FTIR spectra for CH 4 prediction. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Random matrix theory analysis of cross-correlations in the US stock market: Evidence from Pearson’s correlation coefficient and detrended cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Wang, Gang-Jin; Xie, Chi; Chen, Shou; Yang, Jiao-Jiao; Yang, Ming-Yan

    2013-09-01

    In this study, we first build two empirical cross-correlation matrices in the US stock market by two different methods, namely the Pearson’s correlation coefficient and the detrended cross-correlation coefficient (DCCA coefficient). Then, combining the two matrices with the method of random matrix theory (RMT), we mainly investigate the statistical properties of cross-correlations in the US stock market. We choose the daily closing prices of 462 constituent stocks of S&P 500 index as the research objects and select the sample data from January 3, 2005 to August 31, 2012. In the empirical analysis, we examine the statistical properties of cross-correlation coefficients, the distribution of eigenvalues, the distribution of eigenvector components, and the inverse participation ratio. From the two methods, we find some new results of the cross-correlations in the US stock market in our study, which are different from the conclusions reached by previous studies. The empirical cross-correlation matrices constructed by the DCCA coefficient show several interesting properties at different time scales in the US stock market, which are useful to the risk management and optimal portfolio selection, especially to the diversity of the asset portfolio. It will be an interesting and meaningful work to find the theoretical eigenvalue distribution of a completely random matrix R for the DCCA coefficient because it does not obey the Marčenko-Pastur distribution.

  18. The coefficient of determination R2 and intra-class correlation coefficient from generalized linear mixed-effects models revisited and expanded.

    PubMed

    Nakagawa, Shinichi; Johnson, Paul C D; Schielzeth, Holger

    2017-09-01

    The coefficient of determination R 2 quantifies the proportion of variance explained by a statistical model and is an important summary statistic of biological interest. However, estimating R 2 for generalized linear mixed models (GLMMs) remains challenging. We have previously introduced a version of R 2 that we called [Formula: see text] for Poisson and binomial GLMMs, but not for other distributional families. Similarly, we earlier discussed how to estimate intra-class correlation coefficients (ICCs) using Poisson and binomial GLMMs. In this paper, we generalize our methods to all other non-Gaussian distributions, in particular to negative binomial and gamma distributions that are commonly used for modelling biological data. While expanding our approach, we highlight two useful concepts for biologists, Jensen's inequality and the delta method, both of which help us in understanding the properties of GLMMs. Jensen's inequality has important implications for biologically meaningful interpretation of GLMMs, whereas the delta method allows a general derivation of variance associated with non-Gaussian distributions. We also discuss some special considerations for binomial GLMMs with binary or proportion data. We illustrate the implementation of our extension by worked examples from the field of ecology and evolution in the R environment. However, our method can be used across disciplines and regardless of statistical environments. © 2017 The Author(s).

  19. Are Self-Reported Medication Allergies Associated With Worse Hip Outcome Scores Prior to Hip Arthroscopy?

    PubMed

    Sochacki, Kyle R; Jack, Robert A; Bekhradi, Arya; Delgado, Domenica; McCulloch, Patrick C; Harris, Joshua D

    2018-06-01

    To determine if there are significant differences in preoperative patient-reported outcome (PRO) scores in patients with and without self-reported medication allergies undergoing hip arthroscopy. Consecutive subjects undergoing hip arthroscopy for femoroacetabular impingement (FAI) syndrome by a single surgeon were retrospectively reviewed. PROs were collected within 6 weeks of the date of surgery. PROs included International Hip Outcome Tool (iHOT-12), Hip Outcome Score (HOS), and Short-Form (SF-12) scores. Allergies to medications were self-reported preoperatively within 6 weeks of the date of surgery. Patient demographics were recorded. Bivariate correlations and multivariate regression models were calculated to identify associations with baseline hip outcome scores. Two hundred twelve subjects were analyzed (56% female, mean age 35.1 ± 13.2 years). Seventy-two subjects (34%) self-reported allergies (range 1-10; 41 subjects had 1 allergy; 14 subjects had 2; 8 subjects had 3; 2 subjects had 4; 7 subjects had 5 or more). The most commonly reported allergies included penicillin (18), sulfa (13), and codeine (11). Female gender was significantly correlated with number of allergies (Pearson correlation coefficient, 0.188; P < .001). SF-12 Mental Component Score (MCS) was significantly correlated with HOS-ADL (Pearson correlation coefficient, 0.389; P < .001), HOS-SSS (Pearson correlation coefficient, 0.251; P < .001), and iHOT-12 (Pearson correlation coefficient, 0.385; P < .001). There was no significant correlation between number of allergies and all hip PROs. In all multivariate models, the SF-12 MCS had the strongest association with HOS-ADL, HOS-SSS, and iHOT-12 (P < .001 for all). Allergies were not significantly associated with any hip PROs. In patients undergoing hip arthroscopy for FAI syndrome, self-reported medication allergies are not significantly associated with preoperative patient-reported hip outcome scores. Level III, retrospective comparative case series. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  20. Body Adiposity Index Performance in Estimating Body Fat Percentage in Colombian College Students: Findings from the FUPRECOL—Adults Study

    PubMed Central

    Ramírez-Vélez, Robinson; Correa-Bautista, Jorge Enrique; González-Ruíz, Katherine; Vivas, Andrés; Triana-Reina, Héctor Reynaldo; Martínez-Torres, Javier; Prieto-Benavides, Daniel Humberto; Carrillo, Hugo Alejandro; Ramos-Sepúlveda, Jeison Alexander; Villa-González, Emilio; García-Hermoso, Antonio

    2017-01-01

    Recently, a body adiposity index (BAI = (hip circumference)/((height)(1.5))−18) was developed and validated in adult populations. The aim of this study was to evaluate the performance of BAI in estimating percentage body fat (BF%) in a sample of Colombian collegiate young adults. The participants were comprised of 903 volunteers (52% females, mean age = 21.4 years ± 3.3). We used the Lin’s concordance correlation coefficient, linear regression, Bland–Altman’s agreement analysis, concordance correlation coefficient (ρc) and the coefficient of determination (R2) between BAI, and BF%; by bioelectrical impedance analysis (BIA)). The correlation between the two methods of estimating BF% was R2 = 0.384, p < 0.001. A paired-sample t-test showed a difference between the methods (BIA BF% = 16.2 ± 3.1, BAI BF% = 30.0 ± 5.4%; p < 0.001). For BIA, bias value was 6.0 ± 6.2 BF% (95% confidence interval (CI) = −6.0 to 18.2), indicating that the BAI method overestimated BF% relative to the reference method. Lin’s concordance correlation coefficient was poor (ρc = 0.014, 95% CI = −0.124 to 0.135; p = 0.414). In Colombian college students, there was poor agreement between BAI- and BIA-based estimates of BF%, and so BAI is not accurate in people with low or high body fat percentage levels. PMID:28106719

  1. Does leadership effectiveness correlates with leadership styles in healthcare executives of Iran University of Medical Sciences

    PubMed Central

    Ebadifard Azar, Farbod; Sarabi Asiabar, Ali

    2015-01-01

    Background: Effective leadership is essential to passing through obstacles facing the health field.The current health care system in Iran has major problems and gaps in the field of effective leadership. The aim of this study was to evaluate hospital managers’ leadership style through selfassessment and to determine the correlation between leadership styles with healthcare executives’ leadership readiness and leadership effectiveness. Methods: In this cross-sectional study a self-administered questionnaire completed by all internal healthcare executives of all teaching and non-teaching hospitals affiliated to Iran University of Medical Sciences. Questionnaire was composed to determine demographic information, leadership style questions, leadership effectiveness and leadership readiness. Descriptive statistics and Pearson correlation coefficient were used for data analysis. Results: According to the findings, the dominant style of healthcare executives was transformational leadership style (with a score of 4.34). The leadership effectiveness was estimated at about 4.36 that shows the appropriate level of leadership effectiveness. There was a significant correlation (correlation coefficient of 0.244) between leadership readiness and transformational leadership style (p<0.05). Also, there was a significant correlation between leadership effectiveness with transformational (0.051) and transactional (0.216) styles. Conclusion: There was a correlation between leadership readiness and leadership effectiveness with leadership styles. Application of this research will be crucial to universities and healthcare executives. This study suggests that strengthening the scientific basis is essential for leadership readiness and leadership effectiveness in healthcare system. PMID:26000260

  2. Does leadership effectiveness correlates with leadership styles in healthcare executives of Iran University of Medical Sciences.

    PubMed

    Ebadifard Azar, Farbod; Sarabi Asiabar, Ali

    2015-01-01

    Effective leadership is essential to passing through obstacles facing the health field.The current health care system in Iran has major problems and gaps in the field of effective leadership. The aim of this study was to evaluate hospital managers' leadership style through selfassessment and to determine the correlation between leadership styles with healthcare executives' leadership readiness and leadership effectiveness. In this cross-sectional study a self-administered questionnaire completed by all internal healthcare executives of all teaching and non-teaching hospitals affiliated to Iran University of Medical Sciences. Questionnaire was composed to determine demographic information, leadership style questions, leadership effectiveness and leadership readiness. Descriptive statistics and Pearson correlation coefficient were used for data analysis. According to the findings, the dominant style of healthcare executives was transformational leadership style (with a score of 4.34). The leadership effectiveness was estimated at about 4.36 that shows the appropriate level of leadership effectiveness. There was a significant correlation (correlation coefficient of 0.244) between leadership readiness and transformational leadership style (p<0.05). Also, there was a significant correlation between leadership effectiveness with transformational (0.051) and transactional (0.216) styles. There was a correlation between leadership readiness and leadership effectiveness with leadership styles. Application of this research will be crucial to universities and healthcare executives. This study suggests that strengthening the scientific basis is essential for leadership readiness and leadership effectiveness in healthcare system.

  3. [THERMAL STABILITY AS A PROGNOSTIC INDICATOR OF CONSERVATION OF LIVE EMBRYONIC SMALLPOX VACCINE (TEOVAC) DURING STORAGE].

    PubMed

    Zhukov, V A; Kokorev, S V; Rogozhkina, S V; Melnikov, D G; Terentiev, A I; Kovalchuk, E A; Vakhnov, E Yu; Borisevich, S V

    2016-01-01

    Determination of values of coefficients of thermal stability of TEOVac for prognosis of conservation of the vaccine (specific biological activity) during the process of warranty period storage. TEOVac (masticatory tablets) in primary packaging was kept at increased temperature (accelerated and stress-tests) and at the conditions established by PAP for the preparation (long-term tests). Biological activity of the vaccine was determined by titration on 12-day chicken embryos. A correlation between the value of coefficients of thermal stability and conservation of the prepared series of the condition preparation at the final date of storage was experimentally established. Coefficients of thermal stability could be used as a prognostic indicator of quality of the produced pelleted formulation of the preparation for evaluation of conservation of the vaccine during warranty period storage.

  4. Response time correlations for platinum resistance thermometers

    NASA Technical Reports Server (NTRS)

    Pandey, D. K.; Ash, R. L.; Dillon-Townes, L. A.

    1985-01-01

    The 'plunge method' recommended by ASTM has been used to determine the time constant of 100-ohm platinum resistance thermometers (PRT) considered for use in the National Transonic Facility. It is shown that the response time of ventilated PRT can be correlated with the reciprocal of the heat transfer coefficient in a given field. Universal correlations are established for the 100- and 1000-ohm PRT with uncertainties of 20 and 30 percent, respectively. The correlations are found to be consistent with the uncertainty involved in heat transfer correlations available in the literature and are recommended for use in flowing liquids and gases.

  5. Reliability of mercury-in-silastic strain gauge plethysmography curve reading: influence of clinical clues and observer variation.

    PubMed

    Høyer, Christian; Pavar, Susanne; Pedersen, Begitte H; Biurrun Manresa, José A; Petersen, Lars J

    2013-08-01

    Mercury-in-silastic strain gauge pletysmography (SGP) is a well-established technique for blood flow and blood pressure measurements. The aim of this study was to examine (i) the possible influence of clinical clues, e.g. the presence of wounds and color changes during blood pressure measurements, and (ii) intra- and inter-observer variation of curve interpretation for segmental blood pressure measurements. A total of 204 patients with known or suspected peripheral arterial disease (PAD) were included in a diagnostic accuracy trial. Toe and ankle pressures were measured in both limbs, and primary observers analyzed a total of 804 pressure curve sets. The SGP curves were later reanalyzed separately by two observers blinded to clinical clues. Intra- and inter-observer agreement was quantified using Cohen's kappa and reliability was quantified using intra-class correlation coefficients, coefficients of variance, and Bland-Altman analysis. There was an overall agreement regarding patient diagnostic classification (PAD/not PAD) in 202/204 (99.0%) for intra-observer (κ = 0.969, p < 0.001), and 201/204 (98.5%) for inter-observer readings (κ = 0.953, p < 0.001). Reliability analysis showed excellent correlation between blinded versus non-blinded and inter-observer readings for determination of absolute segmental pressures (all intraclass correlation coefficients ≥ 0.984). The coefficient of variance for determination of absolute segmental blood pressure ranged from 2.9-3.4% for blinded/non-blinded data and from 3.8-5.0% for inter-observer data. This study shows a low inter-observer variation among experienced laboratory technicians for reading strain gauge curves. The low variation between blinded/non-blinded readings indicates that SGP measurements are minimally biased by clinical clues.

  6. Identifying presence of correlated errors in GRACE monthly harmonic coefficients using machine learning algorithms

    NASA Astrophysics Data System (ADS)

    Piretzidis, Dimitrios; Sra, Gurveer; Karantaidis, George; Sideris, Michael G.

    2017-04-01

    A new method for identifying correlated errors in Gravity Recovery and Climate Experiment (GRACE) monthly harmonic coefficients has been developed and tested. Correlated errors are present in the differences between monthly GRACE solutions, and can be suppressed using a de-correlation filter. In principle, the de-correlation filter should be implemented only on coefficient series with correlated errors to avoid losing useful geophysical information. In previous studies, two main methods of implementing the de-correlation filter have been utilized. In the first one, the de-correlation filter is implemented starting from a specific minimum order until the maximum order of the monthly solution examined. In the second one, the de-correlation filter is implemented only on specific coefficient series, the selection of which is based on statistical testing. The method proposed in the present study exploits the capabilities of supervised machine learning algorithms such as neural networks and support vector machines (SVMs). The pattern of correlated errors can be described by several numerical and geometric features of the harmonic coefficient series. The features of extreme cases of both correlated and uncorrelated coefficients are extracted and used for the training of the machine learning algorithms. The trained machine learning algorithms are later used to identify correlated errors and provide the probability of a coefficient series to be correlated. Regarding SVMs algorithms, an extensive study is performed with various kernel functions in order to find the optimal training model for prediction. The selection of the optimal training model is based on the classification accuracy of the trained SVM algorithm on the same samples used for training. Results show excellent performance of all algorithms with a classification accuracy of 97% - 100% on a pre-selected set of training samples, both in the validation stage of the training procedure and in the subsequent use of the trained algorithms to classify independent coefficients. This accuracy is also confirmed by the external validation of the trained algorithms using the hydrology model GLDAS NOAH. The proposed method meet the requirement of identifying and de-correlating only coefficients with correlated errors. Also, there is no need of applying statistical testing or other techniques that require prior de-correlation of the harmonic coefficients.

  7. Factors That Attenuate the Correlation Coefficient and Its Analogs.

    ERIC Educational Resources Information Center

    Dolenz, Beverly

    The correlation coefficient is an integral part of many other statistical techniques (analysis of variance, t-tests, etc.), since all analytic methods are actually correlational (G. V. Glass and K. D. Hopkins, 1984). The correlation coefficient is a statistical summary that represents the degree and direction of relationship between two variables.…

  8. A satellite snow depth multi-year average derived from SSM/I for the high latitude regions

    USGS Publications Warehouse

    Biancamaria, S.; Mognard, N.M.; Boone, A.; Grippa, M.; Josberger, E.G.

    2008-01-01

    The hydrological cycle for high latitude regions is inherently linked with the seasonal snowpack. Thus, accurately monitoring the snow depth and the associated aerial coverage are critical issues for monitoring the global climate system. Passive microwave satellite measurements provide an optimal means to monitor the snowpack over the arctic region. While the temporal evolution of snow extent can be observed globally from microwave radiometers, the determination of the corresponding snow depth is more difficult. A dynamic algorithm that accounts for the dependence of the microwave scattering on the snow grain size has been developed to estimate snow depth from Special Sensor Microwave/Imager (SSM/I) brightness temperatures and was validated over the U.S. Great Plains and Western Siberia. The purpose of this study is to assess the dynamic algorithm performance over the entire high latitude (land) region by computing a snow depth multi-year field for the time period 1987-1995. This multi-year average is compared to the Global Soil Wetness Project-Phase2 (GSWP2) snow depth computed from several state-of-the-art land surface schemes and averaged over the same time period. The multi-year average obtained by the dynamic algorithm is in good agreement with the GSWP2 snow depth field (the correlation coefficient for January is 0.55). The static algorithm, which assumes a constant snow grain size in space and time does not correlate with the GSWP2 snow depth field (the correlation coefficient with GSWP2 data for January is - 0.03), but exhibits a very high anti-correlation with the NCEP average January air temperature field (correlation coefficient - 0.77), the deepest satellite snow pack being located in the coldest regions, where the snow grain size may be significantly larger than the average value used in the static algorithm. The dynamic algorithm performs better over Eurasia (with a correlation coefficient with GSWP2 snow depth equal to 0.65) than over North America (where the correlation coefficient decreases to 0.29). ?? 2007 Elsevier Inc. All rights reserved.

  9. Scalar and tensor spherical harmonics expansion of the velocity correlation in homogeneous anisotropic turbulence

    DOE PAGES

    Rubinstein, Robert; Kurien, Susan; Cambon, Claude

    2015-06-22

    The representation theory of the rotation group is applied to construct a series expansion of the correlation tensor in homogeneous anisotropic turbulence. The resolution of angular dependence is the main analytical difficulty posed by anisotropic turbulence; representation theory parametrises this dependence by a tensor analogue of the standard spherical harmonics expansion of a scalar. As a result, the series expansion is formulated in terms of explicitly constructed tensor bases with scalar coefficients determined by angular moments of the correlation tensor.

  10. Chemical and Physical Predictors of the Nutritive Value of Wheat in Broiler Diets

    PubMed Central

    Ball, M. E. E.; Owens, B.; McCracken, K. J.

    2013-01-01

    The aim of this study was to establish relationships between chemical and physical parameters of wheat with performance and digestibilities of feed components in broiler chickens fed on wheat-based diets. Ninety-four wheat samples were selected for inclusion in four bird trials. Birds were housed in individual wire metabolism cages from 7 to 28 d and offered water and feed ad libitum. Dry matter intake (DMI), liveweight gain (LWG) and gain:feed were measured weekly. A balance collection was carried out from 14 to 21 d for determination of apparent metabolizable energy (AME), ME:gain, dry matter retention, oil and neutral detergent fibre (NDF) digestibility. At 28 d the birds were humanely killed, the contents of the jejunum removed for determination of in vivo viscosity and the contents of the ileum removed for determination of ileal dry matter, starch and protein digestibility. When wheat parameters were correlated with bird performance data, it was found that specific weight was not significantly (p>0.05) related to bird performance. Bird DMI, LWG and gain:feed were best correlated (p<0.05) with the rate of starch digestion, although the coefficients of correlation (r) were still low (0.246 to 0.523). A negative relationship (p<0.01) between AME and total (r = −0.432) and soluble (r = −0.304) non starch polysaccharide (NSP) was observed in this study. Thousand grain weight (TG) was positively correlated with DMI (r = 0.299), LWG (r = 0.343) and gain:feed (r = 0.371). When establishing multiple regression relationships, correlation coefficients greater than 0.8 were achieved for DMI, LWG, gain:feed and ileal crude protein digestibility. However, the economics involved in determining the parameters involved in the regressions make the process impractical. PMID:25049711

  11. Thin-film amperometric multibiosensor for simultaneous determination of lactate and glucose in wine.

    PubMed

    Shkotova, Lyudmyla V; Piechniakova, Nataliia Y; Kukla, Oleksandr L; Dzyadevych, Sergei V

    2016-04-15

    An amperometric multi-biosensor based on lactate and glucose oxidases has been developed for determination of lactate and glucose in wine. Gold thin-film amperometric electrodes were used as multi-transducers. Analytical characteristics of the multi-biosensor developed were studied. The minimum detectable concentration was 5×10(-6) mol/l for both glucose and lactate. High reproducibility and storage stability of the multi-biosensor are demonstrated in this paper. Lactate and glucose were determined in wine, and a good correlation was obtained with concentrations determined using high-performance liquid chromatography (correlation coefficient for glucose R(2)=0.998, for lactate R(2)=0.718). Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. [Comparison of two methods for rapid determination of C-reactive protein with the Tina-quant].

    PubMed

    Oremek, G M; Luksaite, R; Bretschneider, I

    2008-03-01

    C-reactive protein (CRP) as an acute phase protein is an important diagnostic marker for the presence and course of human processes. Out of the acute phase proteins it is one of those the concentrations increase most rapidly with its sensitivity being superior to other markers of inflammation, such as leukocytosis, erythrocytic sedimentation rate, and fever. This study compared two-point-of-care assays with the standard laboratory method Tina-quant CRP processed on a Hitachi 917: the immunofiltration assay NycoCard CRP Whole Blood and the turbidimetric immunoassay Micros CRP. Both methods are carried in the presence of a patient, by using capillary or venous blood. Seventy-eight blood samples were analyzed first in the standard laboratory routine and then by both rapid test assays. The precision of both assays was determined from the confidence interval. The results were statistically analyzed by arithmetic standard deviation mean method, variation coefficient, Spearman correlation index, Wilcoxon and Bland-Altman tests, and Passing-Bablock regression. NycoCard CRP Whole Blood showed a correlation coefficient of R = 0.9838; the precision had a coefficient of variation of CV = 1.8759% while As compared with Tina-quant CRP had R = 0.9934 and CV = 0.9160%. Both assays indicated the same results as Tina-quant CRP. Both Tina-quant CRP and NycoCard CRP Whole Blood give the best fit for the rapid determination of CRP.

  13. ppcor: An R Package for a Fast Calculation to Semi-partial Correlation Coefficients.

    PubMed

    Kim, Seongho

    2015-11-01

    Lack of a general matrix formula hampers implementation of the semi-partial correlation, also known as part correlation, to the higher-order coefficient. This is because the higher-order semi-partial correlation calculation using a recursive formula requires an enormous number of recursive calculations to obtain the correlation coefficients. To resolve this difficulty, we derive a general matrix formula of the semi-partial correlation for fast computation. The semi-partial correlations are then implemented on an R package ppcor along with the partial correlation. Owing to the general matrix formulas, users can readily calculate the coefficients of both partial and semi-partial correlations without computational burden. The package ppcor further provides users with the level of the statistical significance with its test statistic.

  14. Comparateur d'étalons de masse: une étude expérimentale des coefficients de corrélation des paramètres mesurés

    NASA Astrophysics Data System (ADS)

    Pinot, P.

    1991-01-01

    The mass comparator for primary standards of the INM is a high level metrological set. Recently, its balance has been put into a thermally isolated and airtight chamber and this has led us to engage in an experimental study concerning the independence of the measured parameters. This study has revealed that the independence hypothesis must be rejected. The different correlation coefficients have been determined.

  15. A determinant-based criterion for working correlation structure selection in generalized estimating equations.

    PubMed

    Jaman, Ajmery; Latif, Mahbub A H M; Bari, Wasimul; Wahed, Abdus S

    2016-05-20

    In generalized estimating equations (GEE), the correlation between the repeated observations on a subject is specified with a working correlation matrix. Correct specification of the working correlation structure ensures efficient estimators of the regression coefficients. Among the criteria used, in practice, for selecting working correlation structure, Rotnitzky-Jewell, Quasi Information Criterion (QIC) and Correlation Information Criterion (CIC) are based on the fact that if the assumed working correlation structure is correct then the model-based (naive) and the sandwich (robust) covariance estimators of the regression coefficient estimators should be close to each other. The sandwich covariance estimator, used in defining the Rotnitzky-Jewell, QIC and CIC criteria, is biased downward and has a larger variability than the corresponding model-based covariance estimator. Motivated by this fact, a new criterion is proposed in this paper based on the bias-corrected sandwich covariance estimator for selecting an appropriate working correlation structure in GEE. A comparison of the proposed and the competing criteria is shown using simulation studies with correlated binary responses. The results revealed that the proposed criterion generally performs better than the competing criteria. An example of selecting the appropriate working correlation structure has also been shown using the data from Madras Schizophrenia Study. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Optimal portfolio strategy with cross-correlation matrix composed by DCCA coefficients: Evidence from the Chinese stock market

    NASA Astrophysics Data System (ADS)

    Sun, Xuelian; Liu, Zixian

    2016-02-01

    In this paper, a new estimator of correlation matrix is proposed, which is composed of the detrended cross-correlation coefficients (DCCA coefficients), to improve portfolio optimization. In contrast to Pearson's correlation coefficients (PCC), DCCA coefficients acquired by the detrended cross-correlation analysis (DCCA) method can describe the nonlinear correlation between assets, and can be decomposed in different time scales. These properties of DCCA make it possible to improve the investment effect and more valuable to investigate the scale behaviors of portfolios. The minimum variance portfolio (MVP) model and the Mean-Variance (MV) model are used to evaluate the effectiveness of this improvement. Stability analysis shows the effect of two kinds of correlation matrices on the estimation error of portfolio weights. The observed scale behaviors are significant to risk management and could be used to optimize the portfolio selection.

  17. Relationships among the slopes of lines derived from various data analysis techniques and the associated correlation coefficient

    NASA Technical Reports Server (NTRS)

    Cohen, S. C.

    1980-01-01

    A technique for fitting a straight line to a collection of data points is given. The relationships between the slopes and correlation coefficients, and between the corresponding standard deviations and correlation coefficient are given.

  18. Establishment of a Simple and Convenient Method for Folic Acid Enzyme Chemiluminescence Immunoassay

    NASA Astrophysics Data System (ADS)

    Liu, Ting; Zeng, Ling; Yu, Zhengwei; Yang, Yanfei; Qu, Yunhuan

    2018-01-01

    The enzyme chemiluminescence new immunoassay for folic acid (FA) was established by competition model. Add FA samples to a microtiter plate precoated with the goat anti-mouse IgG firstly, then add enzyme abled FA and FA monoclonal antibody (McAb). The values of CLIA were measured to reflect the quantity of FA. The limit of detection(LOD) of assay is 0.37ng/mL. The assay shows good correlation during 1∼30 ng/mL with correlation coefficient 0.9976. The intra- and inter-assay coefficients of variation are 4.8 % ∼ 7.3 % and 6.1 % ∼ 12.2 %, respectively. The recovery of folic acid in serum is 90.4 %∼113.2 %. Compared with determine value clinically in chemiluminescence immunoassay kit from Roche company, the correlative equation is y = 0.9689x + 0.0228, and correlation coefficient is 0.9780. Various components and kit overall show good stabilities. This method is simple and convenient, and has low LOD value. The method has overcome the shortcomings of the present references. It is easy to apply and has broad clinical application prospect. It lays an experimental foundation for the preparation of Mc Ab against folic acid and the development of domestic kit.

  19. Investigation into the Effects of Textural Properties on Cuttability Performance of a Chisel Tool

    NASA Astrophysics Data System (ADS)

    Tumac, Deniz; Copur, Hanifi; Balci, Cemal; Er, Selman; Avunduk, Emre

    2018-04-01

    The main objective of this study is to investigate the effect of textural properties of stones on cutting performance of a standard chisel tool. Therewithal, the relationships between textural properties and cutting performance parameters and physical and mechanical properties were statistically analyzed. For this purpose, physical and mechanical property tests and mineralogical and petrographic analyses were carried out on eighteen natural stone samples, which can be grouped into three fundamentally different geological origins, i.e., metamorphic, igneous, and sedimentary. Then, texture coefficient analyses were performed on the samples. To determine the cuttability of the stones; the samples were cut with a portable linear cutting machine using a standard chisel tool at different depths of cut in unrelieved (non-interactive) cutting mode. The average and maximum forces (normal and cutting) and specific energy were measured, and the obtained values were correlated with texture coefficient, packing weighting, and grain size. With reference to the relation between depth of cut and cutting performance of the chisel tool for three types of natural stone groups, specific energy decreases with increasing depth of cut, and cutting forces increase in proportion to the depth of cut. The same is observed for the relationship between packing weighting and both of specific energy and cutter forces. On the other hand, specific energy and the forces decrease while grain size increases. Based on the findings of the present study, texture coefficient has strong correlation with specific energy. Generally, the lower depth of cut values in cutting tests shows higher and more reliable correlations with texture coefficient than the increased depth of cut. The results of cutting tests show also that, at a lower depth of cut (less than 1.5 mm), even stronger correlations can be observed between texture coefficient and cutting performance. Experimental studies indicate that cutting performance of chisel tools can be predicted based on texture coefficients of the natural stones.

  20. Establishment and comparison of three novel methods for the determination of the photodynamic therapy agent 2-[1-hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) in human serum.

    PubMed

    Chen, Lin; Xiao, Qingqing; Zhang, Xian; Yang, Jin

    2016-03-20

    2-[1-Hexyloxyethyl]-2-devinyl pyropheophorbide-a (HPPH) is a second-generation photosensitizer that has been applied in clinical studies of photodynamic therapy for a variety of malignant lesions. Based on the differences in selectivity and labour intensity, three novel methods - fluorescence detection coupled with high performance liquid chromatography (LC-FLD), LC-tandem mass spectrometry (LC-MS/MS) and fluorescence-based microplate reader methods - were developed for the determination of HPPH in human serum, which allowed comparison of fluorescence and MS platform for HPPH quantification. All three methods have been validated and successfully applied to support the clinical pharmacokinetic study of HPPH. The concentrations measured by LC-FLD matched those by LC-MS/MS with a correlation coefficient (r=0.994) and coefficient of determination (r(2)=0.989). Data consistency was also found between the measurements of microplate reader and LC-MS/MS with a correlation coefficient (r=0.999) and coefficient of determination (r(2)=0.998), indicating that fluorescence assay, the low cost alternative with a relatively poorer selectivity, is clearly suitable for the quantification of HPPH. Calibration curves in the methods of LC-FLD and microplate reader were linear (r˃0.998) over the concentration range from 50 to 5000 ng/mL, and linearity was obtained over the concentration range from 5 to 1000 ng/mL in the LC-MS/MS method. Compared with the other two methods, the fluorescence-based microplate reader method with proven high selectivity should be strongly recommended because of obvious advantages such as the lowest labour intensity, the lowest instrument cost, a better sensitivity than LC-FLD and the very rapid determination of large number of samples (24 samples/40 s). Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Physicochemical properties to determine the buoyancy of hollow microspheres (microballoons) prepared by the emulsion solvent diffusion method.

    PubMed

    Sato, Yasunori; Kawashima, Yoshiaki; Takeuchi, Hirofumi; Yamamoto, Hiromitsu

    2003-05-01

    Hollow microspheres (microballoons) floatable on JPXIII No.1 solution were developed as a dosage form capable of floating in the stomach. Hollow microspheres were prepared by the emulsion solvent diffusion method using enteric acrylic polymers with drug in a mixture of dichloromethane and ethanol. It was found that preparation temperature determined the formation of cavity inside the microsphere and the surface smoothness, determining the floatability and the drug release rate of the microballoon. The correlation between the buoyancy of microballoons and their physical properties, e.g. apparent density and roundness of microballoons were elucidated. The drug loading efficiency of microballoons with various types of drug was investigated and correlated to the distribution coefficient of drug between dichloromethane and water. The optimum loading amount of riboflavin in the microballoon was found to impart ideal floatable properties to the microballoons. On the other hand, little entrapment was observed for aspirin due to the low distribution coefficient; however, entrapment improved to some extent upon reduction of the pH of the process.

  2. The use of index tests to determine the mechanical properties of crushed aggregates from Precambrian basement complex rocks, Ado-Ekiti, SW Nigeria

    NASA Astrophysics Data System (ADS)

    Afolagboye, Lekan Olatayo; Talabi, Abel Ojo; Oyelami, Charles Adebayo

    2017-05-01

    This study assessed the possibility of using index tests to determine the mechanical properties of crushed aggregates. The aggregates used in this study were derived from major Precambrian basement rocks in Ado-Ekiti, Nigeria. Regression analyses were performed to determine the empirical relations that mechanical properties of the aggregates may have with the point load strength (IS(50)), Schmidt rebound hammer value (SHR) and unconfined compressive strength (UCS) of the rocks. For all the data, strong correlation coefficients were found between IS(50), SHR, UCS, and mechanical properties of the aggregates. The regression analysis conducted on the different rocks separately showed that correlations coefficients obtained between the IS(50), SHR, UCS and mechanical properties of the aggregates were stronger than those of the grouped rocks. The T-test and F-test showed that the derived models were valid. This study has shown that the mechanical properties of the aggregates can be estimated from IS(50), SHR and USC but the influence of rock type on the relationships should be taken into consideration.

  3. Correlation Between Minimum Apparent Diffusion Coefficient (ADCmin) and Tumor Cellularity: A Meta-analysis.

    PubMed

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2017-07-01

    Diffusion-weighted imaging (DWI) is a magnetic resonance imaging (MRI) technique based on measure of water diffusion that can provide information about tissue microstructure, especially about cell count. Increase of cell density induces restriction of water diffusion and decreases apparent diffusion coefficient (ADC). ADC can be divided into three sub-parameters: ADC minimum or ADC min , mean ADC or ADC mean and ADC maximum or ADC max Some studies have suggested that ADC min shows stronger correlations with cell count in comparison to other ADC fractions and may be used as a parameter for estimation of tumor cellularity. The aim of the present meta-analysis was to summarize correlation coefficients between ADC min and cellularity in different tumors based on large patient data. For this analysis, MEDLINE database was screened for associations between ADC and cell count in different tumors up to September 2016. For this work, only data regarding ADC min were included. Overall, 12 publications with 317 patients were identified. Spearman's correlation coefficient was used to analyze associations between ADC min and cellularity. The reported Pearson correlation coefficients in some publications were converted into Spearman correlation coefficients. The pooled correlation coefficient for all included studies was ρ=-0.59 (95% confidence interval (CI)=-0.72 to -0.45), heterogeneity Tau 2 =0.04 (p<0.0001), I 2 =73%, test for overall effect Z=8.67 (p<0.00001). ADC min correlated moderately with tumor cellularity. The calculated correlation coefficient is not stronger in comparison to the reported coefficient for ADC mean and, therefore, ADC min does not represent a better means to reflect cellularity. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  4. Correlation of human papillomavirus status with apparent diffusion coefficient of diffusion-weighted MRI in head and neck squamous cell carcinomas.

    PubMed

    Driessen, Juliette P; van Bemmel, Alexander J M; van Kempen, Pauline M W; Janssen, Luuk M; Terhaard, Chris H J; Pameijer, Frank A; Willems, Stefan M; Stegeman, Inge; Grolman, Wilko; Philippens, Marielle E P

    2016-04-01

    Identification of prognostic patient characteristics in head and neck squamous cell carcinoma (HNSCC) is of great importance. Human papillomavirus (HPV)-positive HNSCCs have favorable response to (chemo)radiotherapy. Apparent diffusion coefficient, derived from diffusion-weighted MRI, has also shown to predict treatment response. The purpose of this study was to evaluate the correlation between HPV status and apparent diffusion coefficient. Seventy-three patients with histologically proven HNSCC were retrospectively analyzed. Mean pretreatment apparent diffusion coefficient was calculated by delineation of total tumor volume on diffusion-weighted MRI. HPV status was analyzed and correlated to apparent diffusion coefficient. Six HNSCCs were HPV-positive. HPV-positive HNSCC showed significantly lower apparent diffusion coefficient compared to HPV-negative. This correlation was independent of other patient characteristics. In HNSCC, positive HPV status correlates with low mean apparent diffusion coefficient. The favorable prognostic value of low pretreatment apparent diffusion coefficient might be partially attributed to patients with a positive HPV status. © 2015 Wiley Periodicals, Inc. Head Neck 38: E613-E618, 2016. © 2015 Wiley Periodicals, Inc.

  5. Surgical management of congenital heart disease: correlation between hospital costs and the Aristotle complexity score.

    PubMed

    Sinzobahamvya, N; Kopp, T; Photiadis, J; Arenz, C; Schindler, E; Haun, C; Hraska, V; Asfour, B

    2010-09-01

    Hospital costs are expected to correlate with clinical complexity. Do costs for congenital heart surgery correlate with Aristotle complexity scores? 442 inpatient stays in 2008 were evaluated. Aristotle scores and levels were determined. Costs were estimated according to the German Institute for Hospital Reimbursement system. Pearson and Spearman R correlation coefficients and corresponding goodness-of-fit regression coefficients R2 were calculated. Mean basic and comprehensive Aristotle scores were 7.60 +/- 2.74 and 9.23 +/- 2.94 points, respectively. Mean expenses per hospital stay amounted to 29,369 +/- 30,823 Euros. Aristotle basic and comprehensive scores and levels were positively correlated with hospital costs. With a Spearman R of 1 and related R2 of 0.9436, scores of the 6 Aristotle comprehensive levels correlated best. Mean hospital reimbursement was 26,412 +/- 17,962 Euros. Compensation was higher than expenses for patients in comprehensive levels 1 to 3, but much lower for those in levels 4 to 6. Aristotle comprehensive complexity scores were highly correlated with hospital costs. The Aristotle score could be used as a scale to establish the correct reimbursement after congenital heart surgery. Georg Thieme Verlag KG Stuttgart, New York.

  6. Differences between genders in colorectal morphology on CT colonography using a quantitative approach: a pilot study.

    PubMed

    Weber, Charles N; Poff, Jason A; Lev-Toaff, Anna S; Levine, Marc S; Zafar, Hanna M

    To explore quantitative differences between genders in morphologic colonic metrics and determine metric reproducibility. Quantitative colonic metrics from 20 male and 20 female CTC datasets were evaluated twice by two readers; all exams were performed after incomplete optical colonoscopy. Intra-/inter-reader reliability was measured with intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Women had overall decreased colonic volume, increased tortuosity and compactness and lower sigmoid apex height on CTC compared to men (p<0.0001,all). Quantitative measurements in colonic metrics were highly reproducible (ICC=0.9989 and 0.9970; CCC=0.9945). Quantitative morphologic differences between genders can be reproducibility measured. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Determination of suitable drying curve model for bread moisture loss during baking

    NASA Astrophysics Data System (ADS)

    Soleimani Pour-Damanab, A. R.; Jafary, A.; Rafiee, S.

    2013-03-01

    This study presents mathematical modelling of bread moisture loss or drying during baking in a conventional bread baking process. In order to estimate and select the appropriate moisture loss curve equation, 11 different models, semi-theoretical and empirical, were applied to the experimental data and compared according to their correlation coefficients, chi-squared test and root mean square error which were predicted by nonlinear regression analysis. Consequently, of all the drying models, a Page model was selected as the best one, according to the correlation coefficients, chi-squared test, and root mean square error values and its simplicity. Mean absolute estimation error of the proposed model by linear regression analysis for natural and forced convection modes was 2.43, 4.74%, respectively.

  8. Assessment of oxygen saturation in dental pulp of permanent teeth with periodontal disease.

    PubMed

    Giovanella, Larissa Bergesch; Barletta, Fernando Branco; Felippe, Wilson Tadeu; Bruno, Kely Firmino; de Alencar, Ana Helena Gonçalves; Estrela, Carlos

    2014-12-01

    In individuals with periodontal disease, dental pulp status should be determined before a treatment plan is made. Pulse oximeters are promising diagnostic tools to evaluate pulp vascularization. This study used pulse oximetry to determine the level of oxygen saturation in dental pulp of intact permanent teeth with periodontal attachment loss (PAL) and gingival recession (GR) and to evaluate the correlation between periodontal disease and level of oxygen saturation in the pulp. This study included 67 anterior teeth of 35 patients; all teeth showed intact crowns, PAL, a periodontal pocket (PP), and GR. The teeth underwent periodontal examination, cold and electric pulp testing, and pulse oximetry measurements. The Pearson correlation coefficient and a linear regression coefficient were calculated to evaluate the degree of correlation between periodontal disease markers (PAL, PP, and GR) and the level of oxygen saturation in dental pulp. These tests also evaluated possible associations between oxygen saturation and cold and electric pulp testing. PAL, PP, and GR had negative correlations with oxygen saturation in dental pulp. Conversely, no statistically significant association was found between oxygen saturation in dental pulp and the response to electric sensibility testing. Oxygen saturation was lower in the pulp of permanent teeth with PAL, PP, and GR, indicating that periodontal disease correlates with the level of oxygen saturation in the pulp. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  9. Comparison of intravesical prostatic protrusion, prostate volume and serum prostatic-specific antigen in the evaluation of bladder outlet obstruction.

    PubMed

    Lim, Kok Bin; Ho, Henry; Foo, Keong Tatt; Wong, Michael Yuet Chen; Fook-Chong, Stephanie

    2006-12-01

    The aims of this study were to define the relationship between intravesical prostatic protrusion (IPP), prostate-specific antigen (PSA) and prostate volume (PV) and to determine which one of them is the best predictor of bladder outlet obstruction (BOO) due to benign prostatic enlargement. A prospective study of 114 male patients older than 50 years examined between November 2001 and 2002 was performed. They were evaluated with digital rectal examination, International Prostate Symptoms Score, PSA, uroflowmetry, postvoid residual urine measurement, IPP and PV using transabdominal ultrasound scan. Statistical analysis included scatter plot with Spearman's correlation coefficients and nominal logistic regression Prostate volume, IPP and PSA showed parallel correlation. Although all three indices had good correlation with BOO index, IPP was the best. The Spearman rho correlation coefficients were 0.314, 0.408 and 0.507 for PV, PSA and IPP, respectively. Using receiver-operator characteristic curves, the areas under the curve for PV, PSA and IPP were 0.637, 0.703 and 0.772, respectively. The positive predictive values of PV, PSA and IPP were 65%, 68% and 72%, respectively. Using a nominal regression model, IPP remained the most significant independent index to determine BOO. All three non-invasive indices correlate with one another. The study showed that IPP is a better predictor for BOO than PSA or PV.

  10. Predictive validity of disability rating scale in determining functional outcome in patients with severe traumatic brain injury.

    PubMed

    Deepika, Akhil; Devi, B Indira; Shukla, Dhaval

    2017-01-01

    Most patients with severe traumatic brain injury (TBI) are discharged when they have still not recovered completely. Many such patients are not available for follow up. We conducted this study to determine whether the condition at discharge from acute care setting, as assessed with disability rating scale (DRS), correlates with functional outcome at follow up. This study was conducted at a Neurosurgical intensive care unit (ICU) of a tertiary care referral center. This was a prospective observational study. Patients admitted to ICU with a diagnosis of severe TBI were enrolled for the study. On the day of discharge, all patients underwent DRS assessment. A final assessment was performed using Glasgow outcome scale extended (GOSE) at 6 months after discharge from the hospital. The correlation between the DRS scores at the time of discharge with DRS scores and GOSE categories at 6 months after discharge was determined using Spearman's rho correlation coefficient. A total of 88 patients were recruited for the study. The correlation coefficient of DRS at discharge for DRS at 6 months was 0.536 and for GOSE was -0.553. The area under the curve of DRS score at discharge for predicting unfavorable outcome and mortality at 6 months was 0.770 and 0.820, respectively. The predictive validity of DRS is fair to good in determining GOSE at follow-up. Pending availability of a more accurate outcome assessment tool, DRS at discharge can be used as a surrogate outcome for GOSE at follow up.

  11. Correlation analysis of respiratory signals by using parallel coordinate plots.

    PubMed

    Saatci, Esra

    2018-01-01

    The understanding of the bonds and the relationships between the respiratory signals, i.e. the airflow, the mouth pressure, the relative temperature and the relative humidity during breathing may provide the improvement on the measurement methods of respiratory mechanics and sensor designs or the exploration of the several possible applications in the analysis of respiratory disorders. Therefore, the main objective of this study was to propose a new combination of methods in order to determine the relationship between respiratory signals as a multidimensional data. In order to reveal the coupling between the processes two very different methods were used: the well-known statistical correlation analysis (i.e. Pearson's correlation and cross-correlation coefficient) and parallel coordinate plots (PCPs). Curve bundling with the number intersections for the correlation analysis, Least Mean Square Time Delay Estimator (LMS-TDE) for the point delay detection and visual metrics for the recognition of the visual structures were proposed and utilized in PCP. The number of intersections was increased when the correlation coefficient changed from high positive to high negative correlation between the respiratory signals, especially if whole breath was processed. LMS-TDE coefficients plotted in PCP indicated well-matched point delay results to the findings in the correlation analysis. Visual inspection of PCB by visual metrics showed range, dispersions, entropy comparisons and linear and sinusoidal-like relationships between the respiratory signals. It is demonstrated that the basic correlation analysis together with the parallel coordinate plots perceptually motivates the visual metrics in the display and thus can be considered as an aid to the user analysis by providing meaningful views of the data. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. DCE-MRI-Derived Volume Transfer Constant (Ktrans) and DWI Apparent Diffusion Coefficient as Predictive Markers of Short- and Long-Term Efficacy of Chemoradiotherapy in Patients With Esophageal Cancer.

    PubMed

    Ye, Zhi-Min; Dai, Shu-Jun; Yan, Feng-Qin; Wang, Lei; Fang, Jun; Fu, Zhen-Fu; Wang, Yue-Zhen

    2018-01-01

    This study aimed to evaluate both the short- and long-term efficacies of chemoradiotherapy in relation to the treatment of esophageal cancer . This was achieved through the use of dynamic contrast-enhanced magnetic resonance imaging-derived volume transfer constant and diffusion weighted imaging-derived apparent diffusion coefficient . Patients with esophageal cancer were assigned into the sensitive and resistant groups based on respective efficacies in chemoradiotherapy. Dynamic contrast-enhanced magnetic resonance imaging and diffusion weighted imaging were used to measure volume transfer constant and apparent diffusion coefficient, while computed tomography was used to calculate tumor size reduction rate. Pearson correlation analyses were conducted to analyze correlation between volume transfer constant, apparent diffusion coefficient, and the tumor size reduction rate. Receiver operating characteristic curve was constructed to analyze the short-term efficacy of volume transfer constant and apparent diffusion coefficient, while Kaplan-Meier curve was employed for survival rate analysis. Cox proportional hazard model was used for the risk factors for prognosis of patients with esophageal cancer. Our results indicated reduced levels of volume transfer constant, while increased levels were observed in ADC min , ADC mean , and ADC max following chemoradiotherapy. A negative correlation was determined between ADC min , ADC mean , and ADC max , as well as in the tumor size reduction rate prior to chemoradiotherapy, whereas a positive correlation was uncovered postchemoradiotherapy. Volume transfer constant was positively correlated with tumor size reduction rate both before and after chemoradiotherapy. The 5-year survival rate of patients with esophageal cancer having high ADC min , ADC mean , and ADC max and volume transfer constant before chemoradiotherapy was greater than those with respectively lower values. According to the Cox proportional hazard model, ADC mean , clinical stage, degree of differentiation, and tumor stage were all confirmed as being independent risk factors in regard to the prognosis of patients with EC. The findings of this study provide evidence suggesting that volume transfer constant and apparent diffusion coefficient as being tools allowing for the evaluation of both the short- and long-term efficacies of chemoradiotherapy esophageal cancer treatment.

  13. A Study to Determine the Optimal Frequency for Conducting Periodic Dental Examinations (OFDEX)

    DTIC Science & Technology

    1980-06-01

    as the major vehicle by which patients enter into the incremental care system . Unpublished data from studies performed by the Health Care Studies...product-moment correlation was used to measure the strength of the relationship between two variables. Significance tests for correlation coefficients...expected if no relationship existed between variables at given row and column totals. These expected frequencies are then compared to the actual values

  14. Determination of corneal elasticity coefficient using the ORA database.

    PubMed

    Avetisov, Sergei E; Novikov, Ivan A; Bubnova, Irina A; Antonov, Alexei A; Siplivyi, Vladimir I

    2010-07-01

    To propose a new approach for the study of corneal biomechanics using the Reichert Ocular Response Analyzer (ORA) database, which is based on changes in velocity retardation in the central cornea at the peak of flattening. The ORA applanation curve was analyzed using a mathematical technique, which allowed calculation of the elasticity coefficient (Ke), which is primarily characteristic of the elastic properties of the cornea. Elasticity coefficient values were obtained in patients with presumably different biomechanical properties of the cornea: "normal" cornea (71 eyes, normal group), keratoconus (34 eyes, keratoconus group), LASIK (36 eyes, LASIK group), and glaucoma with elevated and compensated intraocular pressure (lOP) (38 eyes, glaucoma group). The mean Ke value in the normal group was 11.05 +/- 1.6, and the corneal thickness correlation coefficient r2 was 0.48. In the keratoconus group, the mean Ke value was 4.91 +/- 1.87 and the corneal thickness correlation coefficient r2 was 0.47. In the LASIK group, Ke and r2 were 5.99 +/- 1.18 and 0.39, respectively. In the glaucoma group, the same eyes that experienced a two-fold reduction in lOP developed a statistically significant reduction in the Ke (1.06 times lower), whereas their corneal hysteresis value increased 1.25 times. The elasticity coefficient calculated using the ORA applanation curve can be used in the evaluation of corneal biomechanical properties.

  15. An anthropometric study to evaluate the correlation between the occlusal vertical dimension and length of the thumb.

    PubMed

    Basnet, Bishal Babu; Parajuli, Prakash Kumar; Singh, Raj Kumar; Suwal, Pramita; Shrestha, Pragya; Baral, Dharanidhar

    2015-01-01

    Establishment of proper occlusal vertical dimension (OVD) is one of the important tasks for successful prosthodontic therapy. An ideal method for determining OVD in terms of cost, time, and instrument requirements has been sought in prosthodontics by various investigators. However, no such single method has been formulated. In the current anthropometric study, the relationship of the length of the thumb to the OVD was tested in two ethnic groups of Nepal, Aryans, and Mongoloids. The result of this study can be useful in determining proper OVD in edentulous patients. The primary aim of the present study was to evaluate the correlation between the length of the thumb and OVD in Aryan and Mongoloid ethnic groups. The secondary aim was to compare the correlation between OVD and other anatomic measurements (eye-ear distance and pupil-to-rima oris distance) in these ethnicities. The OVD, thumb length, eye-ear distance and distance between pupil of eye and rima oris were measured in a total of 500 adult dentulous volunteers. The correlation between OVD and thumb length as well as other anatomic measurements was checked with Pearson's product moment correlation coefficient. Linear regression analysis was performed to determine the relationship of OVD to the length of the thumb. The thumb length was significantly (P≤0.05) correlated with strong and positive values (Pearson's coefficient =0.874 in the whole population, 0.826 in Aryans, and 0.944 in Mongoloids). Regression analysis showed that thumb length was significantly related to OVD in both ethnic groups. Within the limitations of the present study, the result implies that thumb length can be used as an adjunct for establishing OVD in the edentulous patients.

  16. Evaluation of the kinetic energy of the torso by magneto-inertial measurement unit during the sit-to-stand movement.

    PubMed

    Lepetit, Kevin; Ben Mansour, Khalil; Boudaoud, Sofiane; Kinugawa-Bourron, Kiyoka; Marin, Frédéric

    2018-01-23

    Sit-to-stand tests are used in geriatrics as a qualitative issue in order to evaluate motor control and stability. In terms of measured indicators, it is traditionally the duration of the task that is reported, however it appears that the use of the kinetic energy as a new quantitative criterion allows getting a better understanding of musculoskeletal deficits of elderly subjects. The aim of this study was to determine the feasibility to obtain the measure of kinetic energy using magneto-inertial measurement units (MIMU) during sit-to-stand movements at various paces. 26 healthy subjects contributed to this investigation. Measured results were compared to a marker-based motion capture using the correlation coefficient and the normalized root mean square error (nRMSE). nRMSE were below 10% and correlation coefficients were over 0.97. In addition, errors on the mean kinetic energy were also investigated using Bland-Altman 95% limits of agreement (0.63 J-0.77 J), RMSE (0.29 J-0.38 J) and correlation coefficient (0.96-0.98). The results obtained highlighted that the method based on MIMU data could be an alternative to optoelectronic data acquisition to assess the kinetic energy of the torso during the sit-to-stand test, suggesting this method as being a promising alternative to determine kinetic energy during the sit-to-stand movement. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Validation of a Piezoelectric Sensor Array-Based Device for Measurement of Carotid-Femoral Pulse Wave Velocity: The Philips Prototype.

    PubMed

    Xu, Shao-Kun; Hong, Xiang-Fei; Cheng, Yi-Bang; Liu, Chang-Yuan; Li, Yan; Yin, Bin; Wang, Ji-Guang

    2018-03-01

    Multiple piezoelectric pressure mechanotransducers topologized into an array might improve efficiency and accuracy in collecting arterial pressure waveforms for measurement of pulse wave velocity (PWV). In the present study, we validated a piezoelectric sensor array-based prototype (Philips) against the validated and clinically widely used Complior device (Alam Medical). We recruited 33 subjects with a wide distribution of PWV. For the validation, PWV was measured sequentially with the Complior device (four times) and the Philips prototype (three times). With the 99 paired PWV values, we investigated the agreement between the Philips prototype and the Complior device using Pearson correlation analysis and Bland-Altman plot. We also performed analysis on the determinants and reproducibility of PWV measured with both devices. The correlation coefficient for PWV measured with the two devices was 0.92 ( p < 0.0001). Compared with the Complior device, the Philips prototype slightly overestimated PWV by 0.24 (± 2 standard deviations, ± 1.91) m/s, especially when PWV was high. The correlation coefficient between the difference and the average of the Philips and Complior measurements was 0.21 ( p = 0.035). Nonetheless, they had similar determinants. Age, mean arterial pressure, and sex altogether explained 81.6 and 83.9% of the variance of PWV values measured with the Philips prototype and Complior device, respectively. When the two extremes of the three PWV values measured with the Philips prototype and the Complior device were investigated, the coefficients of variation were 8.26 and 3.26%, respectively. Compared with the Complior device, the Philips prototype had similar accuracy, determinants, and reproducibility in measuring PWV.

  18. Diffusion weighted MRI and 18F-FDG PET/CT in non-small cell lung cancer (NSCLC): does the apparent diffusion coefficient (ADC) correlate with tracer uptake (SUV)?

    PubMed

    Regier, M; Derlin, T; Schwarz, D; Laqmani, A; Henes, F O; Groth, M; Buhk, J-H; Kooijman, H; Adam, G

    2012-10-01

    To investigate the potential correlation of the apparent diffusion coefficient assessed by diffusion-weighted MRI (DWI) and glucose metabolism determined by the standardized uptake value (SUV) at 18F-FDG PET/CT in non-small cell lung cancer (NSCLC). 18F-FDG PET/CT and DWI (TR/TE, 2000/66 ms; b-values, 0 and 500 s/mm(2)) were performed in 41 consecutive patients with histologically verified NSCLC. Analysing the PET-CT data calculation of the mean (SUV(mean)) and maximum (SUV(max)) SUV was performed. By placing a region-of-interest (ROI) encovering the entire tumor mean (ADC(mean)) and minimum ADC (ADC(min)) were determined by two independent radiologists. Results of 18F-FDG PET-CT and DWI were compared on a per-patient basis. For statistical analysis Pearson's correlation coefficient, Bland-Altman and regression analysis were assessed. Data analysis revealed a significant inverse correlation of the ADC(min) and SUV(max) (r=-0.46; p=0.032). Testing the correlation of the ADC(min) and SUV(max) for each histological subtype separately revealed that the inverse correlation was good for both adenocarcinomas (r=-0.47; p=0.03) and squamouscell carcinomas (r=-0.71; p=0.002), respectively. No significant correlation was found for the comparison of ADC(min) and SUV(mean) (r=-0.29; p=0.27), ADC(mean) vs. SUV(mean) (r=-0.28; p=0.31) or ADC(mean) vs. SUV(max) (r=-0.33; p=0.23). The κ-value of 0.88 indicated a good agreement between both observers. This preliminary study is the first to verify the relation between the SUV and the ADC in NSCLC. The significant inverse correlation of these two quantitative imaging approaches points out the association of metabolic activity and tumor cellularity. Therefore, DWI with ADC measurement might represent a new prognostic marker in NSCLC. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Use of the Liverpool Elbow Score as a postal questionnaire for the assessment of outcome after total elbow arthroplasty.

    PubMed

    Ashmore, Alexander M; Gozzard, Charles; Blewitt, Neil

    2007-01-01

    The Liverpool Elbow Score (LES) is a newly developed, validated elbow-specific score. It consists of a patient-answered questionnaire (PAQ) and a clinical assessment. The purpose of this study was to determine whether the PAQ portion of the LES could be used independently as a postal questionnaire for the assessment of outcome after total elbow arthroplasty and to correlate the LES and the Mayo Elbow Performance Score (MEPS). A series of 51 total elbow replacements were reviewed by postal questionnaire. Patients then attended the clinic for assessment by use of both the LES and the MEPS. There was an excellent response rate to the postal questionnaire (98%), and 44 elbows were available for clinical review. Good correlation was shown between the LES and the MEPS (Spearman correlation coefficient, 0.84; P < .001) and between the PAQ portion of the LES and the MEPS (Spearman correlation coefficient, 0.76; P < .001). We conclude that there is good correlation between the LES PAQ component and the MEPS, suggesting that outcome assessment is possible by postal questionnaire.

  20. Correlation coefficient measurement of the mode-locked laser tones using four-wave mixing.

    PubMed

    Anthur, Aravind P; Panapakkam, Vivek; Vujicic, Vidak; Merghem, Kamel; Lelarge, Francois; Ramdane, Abderrahim; Barry, Liam P

    2016-06-01

    We use four-wave mixing to measure the correlation coefficient of comb tones in a quantum-dash mode-locked laser under passive and active locked regimes. We study the uncertainty in the measurement of the correlation coefficient of the proposed method.

  1. Counterion adsorption theory of dilute polyelectrolyte solutions: Apparent molecular weight, second virial coefficient, and intermolecular structure factor

    PubMed Central

    Muthukumar, M.

    2012-01-01

    Polyelectrolyte chains are well known to be strongly correlated even in extremely dilute solutions in the absence of additional strong electrolytes. Such correlations result in severe difficulties in interpreting light scattering measurements in the determination of the molecular weight, radius of gyration, and the second virial coefficient of charged macromolecules at lower ionic strengths from added strong electrolytes. By accounting for charge-regularization of the polyelectrolyte by the counterions, we present a theory of the apparent molecular weight, second virial coefficient, and the intermolecular structure factor in dilute polyelectrolyte solutions in terms of concentrations of the polymer and the added strong electrolyte. The counterion adsorption of the polyelectrolyte chains to differing levels at different concentrations of the strong electrolyte can lead to even an order of magnitude discrepancy in the molecular weight inferred from light scattering measurements. Based on counterion-mediated charge regularization, the second virial coefficient of the polyelectrolyte and the interchain structure factor are derived self-consistently. The effect of the interchain correlations, dominating at lower salt concentrations, on the inference of the radius of gyration and on molecular weight is derived. Conditions for the onset of nonmonotonic scattering wave vector dependence of scattered intensity upon lowering the electrolyte concentration and interpretation of the apparent radius of gyration are derived in terms of the counterion adsorption mechanism. PMID:22830728

  2. Oxygen exchange at gas/oxide interfaces: how the apparent activation energy of the surface exchange coefficient depends on the kinetic regime.

    PubMed

    Fielitz, Peter; Borchardt, Günter

    2016-08-10

    In the dedicated literature the oxygen surface exchange coefficient KO and the equilibrium oxygen exchange rate [Fraktur R] are considered to be directly proportional to each other regardless of the experimental circumstances. Recent experimental observations, however, contradict the consequences of this assumption. Most surprising is the finding that the apparent activation energy of KO depends dramatically on the kinetic regime in which it has been determined, i.e. surface exchange controlled vs. mixed or diffusion controlled. This work demonstrates how the diffusion boundary condition at the gas/solid interface inevitably entails a correlation between the oxygen surface exchange coefficient KO and the oxygen self-diffusion coefficient DO in the bulk ("on top" of the correlation between KO and [Fraktur R] for the pure surface exchange regime). The model can thus quantitatively explain the range of apparent activation energies measured in the different regimes: in the surface exchange regime the apparent activation energy only contains the contribution of the equilibrium exchange rate, whereas in the mixed or in the diffusion controlled regime the contribution of the oxygen self-diffusivity has also to be taken into account, which may yield significantly higher apparent activation energies and simultaneously quantifies the correlation KO ∝ DO(1/2) observed for a large number of oxides in the mixed or diffusion controlled regime, respectively.

  3. A partitioned correlation function interaction approach for describing electron correlation in atoms

    NASA Astrophysics Data System (ADS)

    Verdebout, S.; Rynkun, P.; Jönsson, P.; Gaigalas, G.; Froese Fischer, C.; Godefroid, M.

    2013-04-01

    The traditional multiconfiguration Hartree-Fock (MCHF) and configuration interaction (CI) methods are based on a single orthonormal orbital basis. For atoms with many closed core shells, or complicated shell structures, a large orbital basis is needed to saturate the different electron correlation effects such as valence, core-valence and correlation within the core shells. The large orbital basis leads to massive configuration state function (CSF) expansions that are difficult to handle, even on large computer systems. We show that it is possible to relax the orthonormality restriction on the orbital basis and break down the originally very large calculations into a series of smaller calculations that can be run in parallel. Each calculation determines a partitioned correlation function (PCF) that accounts for a specific correlation effect. The PCFs are built on optimally localized orbital sets and are added to a zero-order multireference (MR) function to form a total wave function. The expansion coefficients of the PCFs are determined from a low dimensional generalized eigenvalue problem. The interaction and overlap matrices are computed using a biorthonormal transformation technique (Verdebout et al 2010 J. Phys. B: At. Mol. Phys. 43 074017). The new method, called partitioned correlation function interaction (PCFI), converges rapidly with respect to the orbital basis and gives total energies that are lower than the ones from ordinary MCHF and CI calculations. The PCFI method is also very flexible when it comes to targeting different electron correlation effects. Focusing our attention on neutral lithium, we show that by dedicating a PCF to the single excitations from the core, spin- and orbital-polarization effects can be captured very efficiently, leading to highly improved convergence patterns for hyperfine parameters compared with MCHF calculations based on a single orthogonal radial orbital basis. By collecting separately optimized PCFs to correct the MR function, the variational degrees of freedom in the relative mixing coefficients of the CSFs building the PCFs are inhibited. The constraints on the mixing coefficients lead to small off-sets in computed properties such as hyperfine structure, isotope shift and transition rates, with respect to the correct values. By (partially) deconstraining the mixing coefficients one converges to the correct limits and keeps the tremendous advantage of improved convergence rates that comes from the use of several orbital sets. Reducing ultimately each PCF to a single CSF with its own orbital basis leads to a non-orthogonal CI approach. Various perspectives of the new method are given.

  4. Empirical correlations for axial dispersion coefficient and Peclet number in fixed-bed columns.

    PubMed

    Rastegar, Seyed Omid; Gu, Tingyue

    2017-03-24

    In this work, a new correlation for the axial dispersion coefficient was obtained using experimental data in the literature for axial dispersion in fixed-bed columns packed with particles. The Chung and Wen correlation, the De Ligny correlation are two popular empirical correlations. However, the former lacks the molecular diffusion term and the latter does not consider bed voidage. The new axial dispersion coefficient correlation in this work was based on additional experimental data in the literature by considering both molecular diffusion and bed voidage. It is more comprehensive and accurate. The Peclet number correlation from the new axial dispersion coefficient correlation on the average leads to 12% lower Peclet number values compared to the values from the Chung and Wen correlation, and in many cases much smaller than those from the De Ligny correlation. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Psychometric properties of the Chinese version of Spiritual Index of Well-Being in elderly Taiwanese.

    PubMed

    Wu, Li-Fen; Yang, Shu-Hui; Koo, Malcolm

    2017-01-04

    Spiritual well-being has become an increasingly important issue for the elderly people. The 12-item Spirituality Index of Well-Being (SIWB) is a well-validated instrument for assessing a patient's current spiritual state. However, the psychometric properties of the SIWB in the Chinese elderly populations are not known. Therefore, this study translated the SIWB into Chinese and evaluated its psychometric properties. The English version of the SIWB was first translated into Chinese based on the Brislin's translation model. The psychometric properties of the translated version of the SIWB (SIWB-C) was evaluated in 416 elderly Taiwanese recruited using a purposive sampling procedure from a medical center, a long-term care institution, and a community health center. Convergent validity was accessed using Pearson's correlation coefficients of the SIWB-C, the EQ-5D-3 L health-related quality of life scale, and the Geriatric Depression Scale-5 (GDS-5). Exploratory factor analysis with Varimax rotation was performed to determine the construct validity. Confirmatory factor analysis was conducted for verification of the quality of the factor structures and demonstrating the convergent validity of the SIWB-C. An internal consistency test based on the Cronbach's alpha coefficient and a stability test based on the Guttman split-half coefficient were also performed. Test-retest reliability was evaluated with intraclass correlation coefficient. Exploratory factor analysis confirmed the original two-dimensional structure of the scale. Confirmatory factor analysis indicated a well-fitting model and a fine convergent validity of the SIWB-C. The Cronbach's alpha coefficient and the Guttman split-half coefficient for the SIWB-C were 0.94 and 0.84, respectively. The correlations between the SIWB-C with EQ-5D-3 L and GDS-5 were 0.22 (p < 0.01) and 0.45 (p < 0.05), respectively. The intraclass correlation coefficient of the SIWB-C over a test-retest interval of two weeks was 0.989. The SIWB-C was found to be a potential useful measure of subjective spiritual well-being in elderly Taiwanese. Its application in assessing the spiritual well-being in Mandarin-speaking elderly population warrants further investigation.

  6. An instrumental variable random-coefficients model for binary outcomes

    PubMed Central

    Chesher, Andrew; Rosen, Adam M

    2014-01-01

    In this paper, we study a random-coefficients model for a binary outcome. We allow for the possibility that some or even all of the explanatory variables are arbitrarily correlated with the random coefficients, thus permitting endogeneity. We assume the existence of observed instrumental variables Z that are jointly independent with the random coefficients, although we place no structure on the joint determination of the endogenous variable X and instruments Z, as would be required for a control function approach. The model fits within the spectrum of generalized instrumental variable models, and we thus apply identification results from our previous studies of such models to the present context, demonstrating their use. Specifically, we characterize the identified set for the distribution of random coefficients in the binary response model with endogeneity via a collection of conditional moment inequalities, and we investigate the structure of these sets by way of numerical illustration. PMID:25798048

  7. Determination of molecular diffusion coefficient in n-alkane binary mixtures: empirical correlations.

    PubMed

    De Mezquia, D Alonso; Bou-Ali, M Mounir; Larrañaga, M; Madariaga, J A; Santamaría, C

    2012-03-08

    In this work we have measured the molecular diffusion coefficient of the n-alkane binary series nC(i)-nC(6), nC(i)-nC(10), and nC(i)-nC(12) at 298 K and 1 atm and a mass fraction of 0.5 by using the so-called sliding symmetric tubes technique. The results show that the diffusion coefficient at this concentration is proportional to the inverse viscosity of the mixture. In addition, we have also measured the diffusion coefficient of the systems nC(12)-nC(6), nC(12)-nC(7), and nC(12)-nC(8) as a function of concentration. From the data obtained, it is shown that the diffusion coefficient of the n-alkane binary mixtures at any concentration can be calculated from the molecular weight of the components and the dynamic viscosity of the corresponding mixture at 50% mass fraction.

  8. Testing the Difference of Correlated Agreement Coefficients for Statistical Significance

    ERIC Educational Resources Information Center

    Gwet, Kilem L.

    2016-01-01

    This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…

  9. Stochastic nature of series of waiting times.

    PubMed

    Anvari, Mehrnaz; Aghamohammadi, Cina; Dashti-Naserabadi, H; Salehi, E; Behjat, E; Qorbani, M; Nezhad, M Khazaei; Zirak, M; Hadjihosseini, Ali; Peinke, Joachim; Tabar, M Reza Rahimi

    2013-06-01

    Although fluctuations in the waiting time series have been studied for a long time, some important issues such as its long-range memory and its stochastic features in the presence of nonstationarity have so far remained unstudied. Here we find that the "waiting times" series for a given increment level have long-range correlations with Hurst exponents belonging to the interval 1/2

  10. Stochastic nature of series of waiting times

    NASA Astrophysics Data System (ADS)

    Anvari, Mehrnaz; Aghamohammadi, Cina; Dashti-Naserabadi, H.; Salehi, E.; Behjat, E.; Qorbani, M.; Khazaei Nezhad, M.; Zirak, M.; Hadjihosseini, Ali; Peinke, Joachim; Tabar, M. Reza Rahimi

    2013-06-01

    Although fluctuations in the waiting time series have been studied for a long time, some important issues such as its long-range memory and its stochastic features in the presence of nonstationarity have so far remained unstudied. Here we find that the “waiting times” series for a given increment level have long-range correlations with Hurst exponents belonging to the interval 1/2

  11. Oblique rotaton in canonical correlation analysis reformulated as maximizing the generalized coefficient of determination.

    PubMed

    Satomura, Hironori; Adachi, Kohei

    2013-07-01

    To facilitate the interpretation of canonical correlation analysis (CCA) solutions, procedures have been proposed in which CCA solutions are orthogonally rotated to a simple structure. In this paper, we consider oblique rotation for CCA to provide solutions that are much easier to interpret, though only orthogonal rotation is allowed in the existing formulations of CCA. Our task is thus to reformulate CCA so that its solutions have the freedom of oblique rotation. Such a task can be achieved using Yanai's (Jpn. J. Behaviormetrics 1:46-54, 1974; J. Jpn. Stat. Soc. 11:43-53, 1981) generalized coefficient of determination for the objective function to be maximized in CCA. The resulting solutions are proved to include the existing orthogonal ones as special cases and to be rotated obliquely without affecting the objective function value, where ten Berge's (Psychometrika 48:519-523, 1983) theorems on suborthonormal matrices are used. A real data example demonstrates that the proposed oblique rotation can provide simple, easily interpreted CCA solutions.

  12. Estimating the total energy demand for supra-maximal exercise using the VO2-power regression from an incremental exercise test.

    PubMed

    Aisbett, B; Le Rossignol, P

    2003-09-01

    The VO2-power regression and estimated total energy demand for a 6-minute supra-maximal exercise test was predicted from a continuous incremental exercise test. Sub-maximal VO2-power co-ordinates were established from the last 40 seconds (s) of 150-second exercise stages. The precision of the estimated total energy demand was determined using the 95% confidence interval (95% CI) of the estimated total energy demand. The linearity of the individual VO2-power regression equations was determined using Pearson's correlation coefficient. The mean 95% CI of the estimated total energy demand was 5.9 +/- 2.5 mL O2 Eq x kg(-1) x min(-1), and the mean correlation coefficient was 0.9942 +/- 0.0042. The current study contends that the sub-maximal VO2-power co-ordinates from a continuous incremental exercise test can be used to estimate supra-maximal energy demand without compromising the precision of the accumulated oxygen deficit (AOD) method.

  13. Radiological Impact of Tritium from Gaseous Effluent Releases at Cook Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Young, Joshua Allan

    The purpose of this study was to investigate the washout of tritiated water by snow and rain from gaseous effluent releases at Donald C. Cook Nuclear Power Plant. Primary concepts studied were determination of washout coefficients for rainfall and snowfall; correlations between rainfall and snow fall tritium concentrations with tritium concentrations in the spent fuel pool, reactor cooling systems, and tritium release rates; and calculations of received doses from the process of recapture. The dose calculations are under the assumption of a maximally exposed individual to get the most conservative estimate of the effect that washout of tritiated water has on individuals around the plant site. This study is in addition to previous work that has been conducted at Cook Nuclear Power Plant for several years. The calculated washout coefficients were typically within the range of 1x10-7s -1 to 1x10-5s-1. A strong correlation between tritium concentration within the spent fuel pool and the tritium release rates was determined.

  14. Developing a Psychometric Instrument to Measure Physical Education Teachers' Job Demands and Resources.

    PubMed

    Zhang, Tan; Chen, Ang

    2017-01-01

    Based on the job demands-resources model, the study developed and validated an instrument that measures physical education teachers' job demands-resources perception. Expert review established content validity with the average item rating of 3.6/5.0. Construct validity and reliability were determined with a teacher sample ( n = 397). Exploratory factor analysis established a five-dimension construct structure matching the theoretical construct deliberated in the literature. The composite reliability scores for the five dimensions range from .68 to .83. Validity coefficients (intraclass correlational coefficients) are .69 for job resources items and .82 for job demands items. Inter-scale correlational coefficients range from -.32 to .47. Confirmatory factor analysis confirmed the construct validity with high dimensional factor loadings (ranging from .47 to .84 for job resources scale and from .50 to .85 for job demands scale) and adequate model fit indexes (root mean square error of approximation = .06). The instrument provides a tool to measure physical education teachers' perception of their working environment.

  15. Developing a Psychometric Instrument to Measure Physical Education Teachers’ Job Demands and Resources

    PubMed Central

    Zhang, Tan; Chen, Ang

    2017-01-01

    Based on the job demands–resources model, the study developed and validated an instrument that measures physical education teachers’ job demands–resources perception. Expert review established content validity with the average item rating of 3.6/5.0. Construct validity and reliability were determined with a teacher sample (n = 397). Exploratory factor analysis established a five-dimension construct structure matching the theoretical construct deliberated in the literature. The composite reliability scores for the five dimensions range from .68 to .83. Validity coefficients (intraclass correlational coefficients) are .69 for job resources items and .82 for job demands items. Inter-scale correlational coefficients range from −.32 to .47. Confirmatory factor analysis confirmed the construct validity with high dimensional factor loadings (ranging from .47 to .84 for job resources scale and from .50 to .85 for job demands scale) and adequate model fit indexes (root mean square error of approximation = .06). The instrument provides a tool to measure physical education teachers’ perception of their working environment. PMID:29200808

  16. Spatiotemporal patterns of correlation between atmospheric nitrogen dioxide and aerosols over South Asia

    NASA Astrophysics Data System (ADS)

    ul-Haq, Zia; Tariq, Salman; Ali, Muhammad

    2017-10-01

    An accurate knowledge is needed on the complex relation between atmospheric trace gasses and aerosol variability and their sources to explain trace gases-aerosols-climate interaction and next-generation modeling of climate change and air quality. In this regard, we have used tropospheric Nitrogen Dioxide (NO2), Aerosol Optical Depth (AOD) and Angstrom Exponent (AE) obtained from satellite-based Ozone Monitoring Instrument (OMI)/Aura and Moderate-Resolution Imaging Spectroradiometer (MODIS)/Aqua over South Asia. NO2-AOD correlation with coefficient r = 0.49 is determined over the landmass of South Asia during 2005-2015. Yearly mean NO2-AOD correlation over South Asia shows large variations ranging from r = 0.32 to 0.86 in 2008 and 2009, respectively. The highest correlation ( r = 0.66) is seen over eastern regions of Bangladesh and India, as well as adjoining areas of western Myanmar mostly linked to anthropogenic activities. A significant correlation ( r = 0.59) associated with natural causes is found over some parts of Sistan region, located at the borders of Iran, Pakistan and Afghanistan, and adjoining territory. We find significant positive correlations for monsoon and post-monsoon seasons with r = 0.50 and r = 0.61, respectively. A linear regression on the annual correlation coefficients data suggests that NO2-AOD correlation is strengthening with an increase of 12.9% over South Asia during the study period. The spatial distribution of data slopes reveals positive trends in NO2-AOD correlation over megacities Lahore, Dhaka, Mumbai and Kolkata linked to growing anthropogenic activities. Singrauli city (India) has the highest correlation ( r = 0.62) and 35% increase in correlation coefficient value per year. A negative correlation is observed for megacity Karachi ( r = -0.37) suggesting the non-commonality of NO2 and aerosols emission sources. AE has also been used to discuss its correlation with NO2 over the areas with dominance of fine-mode aerosols.

  17. Validation study of an electronic method of condensed outcomes tools reporting in orthopaedics.

    PubMed

    Farr, Jack; Verma, Nikhil; Cole, Brian J

    2013-12-01

    Patient-reported outcomes (PRO) instruments are a vital source of data for evaluating the efficacy of medical treatments. Historically, outcomes instruments have been designed, validated, and implemented as paper-based questionnaires. The collection of paper-based outcomes information may result in patients becoming fatigued as they respond to redundant questions. This problem is exacerbated when multiple PRO measures are provided to a single patient. In addition, the management and analysis of data collected in paper format involves labor-intensive processes to score and render the data analyzable. Computer-based outcomes systems have the potential to mitigate these problems by reformatting multiple outcomes tools into a single, user-friendly tool.The study aimed to determine whether the electronic outcomes system presented produces results comparable with the test-retest correlations reported for the corresponding orthopedic paper-based outcomes instruments.The study is designed as a crossover study based on consecutive orthopaedic patients arriving at one of two designated orthopedic knee clinics.Patients were assigned to complete either a paper or a computer-administered questionnaire based on a similar set of questions (Knee injury and Osteoarthritis Outcome Score, International Knee Documentation Committee form, 36-Item Short Form survey, version 1, Lysholm Knee Scoring Scale). Each patient completed the same surveys using the other instrument, so that all patients had completed both paper and electronic versions. Correlations between the results from the two modes were studied and compared with test-retest data from the original validation studies.The original validation studies established test-retest reliability by computing correlation coefficients for two administrations of the paper instrument. Those correlation coefficients were all in the range of 0.7 to 0.9, which was deemed satisfactory. The present study computed correlation coefficients between the paper and electronic modes of administration. These correlation coefficients demonstrated similar results with an overall value of 0.86.On the basis of the correlation coefficients, the electronic application of commonly used knee outcome scores compare variably to the traditional paper variants with a high rate of test-retest correlation. This equivalence supports the use of the condensed electronic outcomes system and validates comparison of scores between electronic and paper modes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. Calcaneotalar ratio: a new concept in the estimation of the length of the calcaneus.

    PubMed

    David, Vikram; Stephens, Terry J; Kindl, Radek; Ang, Andy; Tay, Wei-Han; Asaid, Rafik; McCullough, Keith

    2015-01-01

    Maintaining the calcaneal length after calcaneal fractures is vital to restoring the normal biomechanics of the foot, because it acts as an important lever arm to the plantarflexors of the foot. However, estimation of the length of the calcaneus to be reconstructed in comminuted calcaneal fractures can be difficult. We propose a new method to reliably estimate the calcaneal length radiographically by defining the calcaneotalar length ratio. A total of 100 ankle radiographs with no fracture in the calcaneus or talus taken in skeletally mature patients were reviewed by 6 observers. The anteroposterior lengths of the calcaneus and talus were measured, and the calcaneotalar length ratio was determined. The ratio was then used to estimate the length of the calcaneus. Interobserver reliability was determined using Cronbach's α coefficient and Pearson's correlation coefficient. The mean length of the calcaneus was 75 ± 0.6 mm, and the mean length of the talus was 59 ± 0.5 mm. The calcaneotalar ratio was 1.3. Using this ratio and multiplying it by the talar length, the mean average estimated length of the calcaneus was within 0.7 mm of the known calcaneal length. Cronbach's α coefficient and Pearson's correlation coefficient showed excellent interobserver reliability. The proposed calcaneotalar ratio is a new and reliable method to radiographically estimate the normal length of the calcaneus when reconstructing the calcaneus. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  19. A new method to estimate average hourly global solar radiation on the horizontal surface

    NASA Astrophysics Data System (ADS)

    Pandey, Pramod K.; Soupir, Michelle L.

    2012-10-01

    A new model, Global Solar Radiation on Horizontal Surface (GSRHS), was developed to estimate the average hourly global solar radiation on the horizontal surfaces (Gh). The GSRHS model uses the transmission function (Tf,ij), which was developed to control hourly global solar radiation, for predicting solar radiation. The inputs of the model were: hour of day, day (Julian) of year, optimized parameter values, solar constant (H0), latitude, and longitude of the location of interest. The parameter values used in the model were optimized at a location (Albuquerque, NM), and these values were applied into the model for predicting average hourly global solar radiations at four different locations (Austin, TX; El Paso, TX; Desert Rock, NV; Seattle, WA) of the United States. The model performance was assessed using correlation coefficient (r), Mean Absolute Bias Error (MABE), Root Mean Square Error (RMSE), and coefficient of determinations (R2). The sensitivities of parameter to prediction were estimated. Results show that the model performed very well. The correlation coefficients (r) range from 0.96 to 0.99, while coefficients of determination (R2) range from 0.92 to 0.98. For daily and monthly prediction, error percentages (i.e. MABE and RMSE) were less than 20%. The approach we proposed here can be potentially useful for predicting average hourly global solar radiation on the horizontal surface for different locations, with the use of readily available data (i.e. latitude and longitude of the location) as inputs.

  20. Comparison of rotational temperature derived from ground-based OH airglow observations with TIMED/SABER to evaluate the Einstein Coefficients

    NASA Astrophysics Data System (ADS)

    Liu, W.; Xu, J.; Smith, A. K.; Yuan, W.

    2017-12-01

    Ground-based observations of the OH(9-4, 8-3, 6-2, 5-1, 3-0) band airglows over Xinglong, China (40°24'N, 117°35'E) from December 2011 to 2014 are used to calculate rotational temperatures. The temperatures are calculated using five commonly used Einstein coefficient datasets. The kinetic temperature from TIMED/SABER is completely independent of the OH rotational temperature. SABER temperatures are weighted vertically by weighting functions calculated for each emitting vibrational state from two SABER OH volume emission rate profiles. By comparing the ground-based OH rotational temperature with SABER's, five Einstein coefficient datasets are evaluated. The results show that temporal variations of the rotational temperatures are well correlated with SABER's; the linear correlation coefficients are higher than 0.72, but the slopes of the fit between the SABER and rotational temperatures are not equal to 1. The rotational temperatures calculated using each set of Einstein coefficients produce a different bias with respect to SABER; these are evaluated over each of vibrational levels to assess the best match. It is concluded that rotational temperatures determined using any of the available Einstein coefficient datasets have systematic errors. However, of the five sets of coefficients, the rotational temperature derived with the Langhoff et al.'s (1986) set is most consistent with SABER. In order to get a set of optimal Einstein coefficients for rotational temperature derivation, we derive the relative values from ground-based OH spectra and SABER temperatures statistically using three year data. The use of a standard set of Einstein coefficients will be beneficial for comparing rotational temperatures observed at different sites.

  1. Correlation of standardized uptake value and apparent diffusion coefficient in integrated whole-body PET/MRI of primary and recurrent cervical cancer.

    PubMed

    Grueneisen, Johannes; Beiderwellen, Karsten; Heusch, Philipp; Buderath, Paul; Aktas, Bahriye; Gratz, Marcel; Forsting, Michael; Lauenstein, Thomas; Ruhlmann, Verena; Umutlu, Lale

    2014-01-01

    To evaluate a potential correlation of the maximum standard uptake value (SUVmax) and the minimum apparent diffusion coefficient (ADCmin) in primary and recurrent cervical cancer based on integrated PET/MRI examinations. 19 consecutive patients (mean age 51.6 years; range 30-72 years) with histopathologically confirmed primary cervical cancer (n = 9) or suspected tumor recurrence (n = 10) were prospectively enrolled for an integrated PET/MRI examination. Two radiologists performed a consensus reading in random order, using a dedicated post-processing software. Polygonal regions of interest (ROI) covering the entire tumor lesions were drawn into PET/MR images to assess SUVmax and into ADC parameter maps to determine ADCmin values. Pearson's correlation coefficients were calculated to assess a potential correlation between the mean values of ADCmin and SUVmax. In 15 out of 19 patients cervical cancer lesions (n = 12) or lymph node metastases (n = 42) were detected. Mean SUVmax (12.5 ± 6.5) and ADCmin (644.5 ± 179.7 × 10(-5) mm2/s) values for all assessed tumor lesions showed a significant but weak inverse correlation (R = -0.342, p < 0.05). When subdivided in primary and recurrent tumors, primary tumors and associated primary lymph node metastases revealed a significant and strong inverse correlation between SUVmax and ADCmin (R = -0.692, p < 0.001), whereas recurrent cancer lesions did not show a significant correlation. These initial results of this emerging hybrid imaging technique demonstrate the high diagnostic potential of simultaneous PET/MR imaging for the assessment of functional biomarkers, revealing a significant and strong correlation of tumor metabolism and higher cellularity in cervical cancer lesions.

  2. Estimating Seven Coefficients of Pairwise Relatedness Using Population-Genomic Data

    PubMed Central

    Ackerman, Matthew S.; Johri, Parul; Spitze, Ken; Xu, Sen; Doak, Thomas G.; Young, Kimberly; Lynch, Michael

    2017-01-01

    Population structure can be described by genotypic-correlation coefficients between groups of individuals, the most basic of which are the pairwise relatedness coefficients between any two individuals. There are nine pairwise relatedness coefficients in the most general model, and we show that these can be reduced to seven coefficients for biallelic loci. Although all nine coefficients can be estimated from pedigrees, six coefficients have been beyond empirical reach. We provide a numerical optimization procedure that estimates all seven reduced coefficients from population-genomic data. Simulations show that the procedure is nearly unbiased, even at 3× coverage, and errors in five of the seven coefficients are statistically uncorrelated. The remaining two coefficients have a negative correlation of errors, but their sum provides an unbiased assessment of the overall correlation of heterozygosity between two individuals. Application of these new methods to four populations of the freshwater crustacean Daphnia pulex reveal the occurrence of half siblings in our samples, as well as a number of identical individuals that are likely obligately asexual clone mates. Statistically significant negative estimates of these pairwise relatedness coefficients, including inbreeding coefficients that were typically negative, underscore the difficulties that arise when interpreting genotypic correlations as estimations of the probability that alleles are identical by descent. PMID:28341647

  3. Lipophilicity of a series of 1,2-benzisothiazol-3(2H)-ones determined by reversed-phase thin-layer chromatography.

    PubMed

    Sławik, Tomasz; Kowalski, Cezary

    2002-04-05

    The lipophilicity (R(Mo)) and specific hydrophobic surface area of seven 1,2-benzisothiazol-3(2H)-ones have been determined by reversed-phase TLC and the effect of different mobile-phase modifiers (acetone, acetonitrile, methanol) on the retention has been studied. The linear correlations between the volume fraction of the organic solvent and the R(M) values over a limited range were established for each solute with high values of correlation coefficients (>0.99). The influence of solvent pH on R(M) values was investigated.

  4. Utility of untimed single urine protein/creatinine ratio as a substitute for 24-h proteinuria for assessment of proteinuria in systemic lupus erythematosus.

    PubMed

    Medina-Rosas, Jorge; Gladman, Dafna D; Su, Jiandong; Sabapathy, Arthy; Urowitz, Murray B; Touma, Zahi

    2015-10-24

    In this study, we determined: (1) the utility of an untimed sample of urine protein/creatinine ratio (PCR) as a screening test for proteinuria, (2) its ability to accurately measure proteinuria, and (3) cutoff values for PCR predicting protein content in a 24-h urine collection sample (24hP) of 0.5, 1.0, and 2.0 g/day. Analysis was performed on data from a single lupus cohort (2008-2014). Proteinuria was measured in a 24hP and with PCR. On the basis of 24hP, samples were divided into 4 groups: group 1, <0.5 g/day; group 2, 0.5-0.99 g/day; group 3, 1-1.99 g/day; and group 4, ≥2 g/day. To determine the validity of PCR in screening for proteinuria, the Pearson correlation coefficient was determined for the urine samples with normal PCR (<0.05 g/mmol) and normal 24hP (<0.5 g/day). The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PCR were calculated. To determine the ability of PCR to accurately measure the level of proteinuria, in addition to the correlation between 24hP and PCR, agreement was determined by intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plot between 24hP/24hC and PCR. The best cutoffs for PCR predicting a 24hP of 0.5, 1.0, and 2.0 g/day were determined with the receiver operating characteristic curve. The correlation of the samples with normal PCR as well as 24hP (n = 552) was 0.29 (p < 0.0001). PCR sensitivity and specificity against 24hP were 91 % and 83 %, respectively. The PPV was 82.5 %, and the NPV was 91.4 %. The correlation for all samples (n = 1233) was high, but low to moderate for groups 1, 2, 3, and 4. The agreement for all samples was appropriate but poor for groups 1, 2, 3, and 4. PCR cutoffs for 24hP of 0.5, 1.0, and 2.0 g/day were 0.08, 0.16, and 0.35 g/mmol, respectively. PCR can be used as a screening test for proteinuria, and the best cutoff value to predict a 24hP of 0.5 g/day is 0.08 g/mmol (800 mg/g). The accurate level of proteinuria should be measured by the gold standard test, 24hP.

  5. Spatiotemporal image correlation-derived volumetric Doppler impedance indices from spherical samples of the placenta: intraobserver reliability and correlation with conventional umbilical artery Doppler indices.

    PubMed

    Welsh, A W; Hou, M; Meriki, N; Martins, W P

    2012-10-01

    Volumetric impedance indices derived from spatiotemporal image correlation (STIC) power Doppler ultrasound (PDU) might overcome the influence of machine settings and attenuation. We examined the feasibility of obtaining these indices from spherical samples of anterior placentas in healthy pregnancies, and assessed intraobserver reliability and correlation with conventional umbilical artery (UA) impedance indices. Uncomplicated singleton pregnancies with anterior placenta were included in the study. A single observer evaluated UA pulsatility index (PI), resistance index (RI) and systolic/diastolic ratio (S/D) and acquired three STIC-PDU datasets from the placenta just above the placental cord insertion. Another observer analyzed the STIC-PDU datasets using Virtual Organ Computer-aided AnaLysis (VOCAL) spherical samples from every frame to determine the vascularization index (VI) and vascularization flow index (VFI); maximum, minimum and average values were used to determine the three volumetric impedance indices (vPI, vRI, vS/D). Intraobserver reliability was examined by intraclass correlation coefficients (ICC) and association between volumetric indices from placenta, and UA Doppler indices were assessed by Pearson's correlation coefficient. A total of 25 pregnant women were evaluated but five were excluded because of artifacts observed during analysis. The reliability of measurement of volumetric indices of both VI and VFI from three STIC-PDU datasets was similar, with all ICCs ≥ 0.78. Pearson's r values showed a weak and non-significant correlation between UA pulsed-wave Doppler indices and their respective volumetric indices from spherical samples of placenta (all r ≥ 0.23). VOCAL indices from specific phases of the cardiac cycle showed good repeatability (ICC ≥ 0.92). Volumetric impedance indices determined from spherical samples of placenta are sufficiently reliable but do not correlate with UA Doppler indices in healthy pregnancies. Copyright © 2012 ISUOG. Published by John Wiley & Sons, Ltd.

  6. Reproducibility of abdominal fat assessment by ultrasound and computed tomography

    PubMed Central

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. PMID:28670024

  7. Reproducibility of abdominal fat assessment by ultrasound and computed tomography.

    PubMed

    Mauad, Fernando Marum; Chagas-Neto, Francisco Abaeté; Benedeti, Augusto César Garcia Saab; Nogueira-Barbosa, Marcello Henrique; Muglia, Valdair Francisco; Carneiro, Antonio Adilton Oliveira; Muller, Enrico Mattana; Elias Junior, Jorge

    2017-01-01

    To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.

  8. Fluctuating Navier-Stokes equations for inelastic hard spheres or disks.

    PubMed

    Brey, J Javier; Maynar, P; de Soria, M I García

    2011-04-01

    Starting from the fluctuating Boltzmann equation for smooth inelastic hard spheres or disks, closed equations for the fluctuating hydrodynamic fields to Navier-Stokes order are derived. This requires deriving constitutive relations for both the fluctuating fluxes and the correlations of the random forces. The former are identified as having the same form as the macroscopic average fluxes and involving the same transport coefficients. On the other hand, the random force terms exhibit two peculiarities as compared with their elastic limit for molecular systems. First, they are not white but have some finite relaxation time. Second, their amplitude is not determined by the macroscopic transport coefficients but involves new coefficients. ©2011 American Physical Society

  9. Reliability of Leg and Vertical Stiffness During High Speed Treadmill Running.

    PubMed

    Pappas, Panagiotis; Dallas, Giorgos; Paradisis, Giorgos

    2017-04-01

    In research, the accurate and reliable measurement of leg and vertical stiffness could contribute to valid interpretations. The current study aimed at determining the intraparticipant variability (ie, intraday and interday reliabilities) of leg and vertical stiffness, as well as related parameters, during high speed treadmill running, using the "sine-wave" method. Thirty-one males ran on a treadmill at 6.67 m∙s -1 , and the contact and flight times were measured. To determine the intraday reliability, three 10-s running bouts with 10-min recovery were performed. In addition, to examine the interday reliability, three 10-s running bouts on 3 separate days with 48-h interbout intervals were performed. The reliability statistics included repeated-measure analysis of variance, average intertrial correlations, intraclass correlation coefficients (ICCs), Cronbach's α reliability coefficient, and the coefficient of variation (CV%). Both intraday and interday reliabilities were high for leg and vertical stiffness (ICC > 0.939 and CV < 4.3%), as well as related variables (ICC > 0.934 and CV < 3.9%). It was thus inferred that the measurements of leg and vertical stiffness, as well as the related parameters obtained using the "sine-wave" method during treadmill running at 6.67 m∙s -1 , were highly reliable, both within and across days.

  10. Analysis of Manning’s and Drag Coefficients for Flexible Submerged Vegetation

    NASA Astrophysics Data System (ADS)

    Yusof, Khamaruzaman Wan; Mujahid Muhammad, Muhammad; Mustafa, Muhammad Raza Ul; Azazi Zakaria, Nor; Gahani, Aminuddin Ab.

    2017-06-01

    Accurate determination of flow resistance is of great significance in modelling of open channels that will convey water efficiently. Although, resistance or drag induced by vegetation have been systematically studied for several decades, estimating of the resistance remain as a challenge. This is because most of previous studies use artificial vegetation to investigate flow - vegetation interactions. To overcome this, the present study evaluates the vegetation resistance in terms of Manning’s roughness coefficient and drag coefficient using a natural flexible vegetation (cow grass) under submerged condition. From the experimental result obtained, it was observed that the Manning’s and drag coefficients decreased with the increasing in average velocity. Also, graphical relationship between Manning’s coefficient, n and drag coefficient, CD has been developed with R2 = 0.9465, which indicate that there exist a strong correlation between n and CD, and one can use the proposed graphical model to predict the n - values corresponding to the CD - values.

  11. Attenuation of the Squared Canonical Correlation Coefficient under Varying Estimates of Score Reliability

    ERIC Educational Resources Information Center

    Wilson, Celia M.

    2010-01-01

    Research pertaining to the distortion of the squared canonical correlation coefficient has traditionally been limited to the effects of sampling error and associated correction formulas. The purpose of this study was to compare the degree of attenuation of the squared canonical correlation coefficient under varying conditions of score reliability.…

  12. Thin and Slow Smoke Detection by Using Frequency Image

    NASA Astrophysics Data System (ADS)

    Zheng, Guang; Oe, Shunitiro

    In this paper, a new method to detect thin and slow smoke for early fire alarm by using frequency image has been proposed. The correlation coefficient of the frequency image between the current stage and the initial stage are calculated, so are the gray image correlation coefficient of the color image. When the thin smoke close to transparent enters into the camera view, the correlation coefficient of the frequency image becomes small, while the gray image correlation coefficient of the color image hardly change and keep large. When something which is not transparent, like human beings, etc., enters into the camera view, the correlation coefficient of the frequency image becomes small, as well as that of color image. Based on the difference of correlation coefficient between frequency image and color image in different situations, the thin smoke can be detected. Also, considering the movement of the thin smoke, miss detection caused by the illustration change or noise can be avoided. Several experiments in different situations are carried out, and the experimental results show the effect of the proposed method.

  13. Fluorescence correlation spectroscopy experiments to quantify free diffusion coefficients in reaction-diffusion systems: The case of Ca2 + and its dyes

    NASA Astrophysics Data System (ADS)

    Sigaut, Lorena; Villarruel, Cecilia; Ponce, María Laura; Ponce Dawson, Silvina

    2017-06-01

    Many cell signaling pathways involve the diffusion of messengers that bind and unbind to and from intracellular components. Quantifying their net transport rate under different conditions then requires having separate estimates of their free diffusion coefficient and binding or unbinding rates. In this paper, we show how performing sets of fluorescence correlation spectroscopy (FCS) experiments under different conditions, it is possible to quantify free diffusion coefficients and on and off rates of reaction-diffusion systems. We develop the theory and present a practical implementation for the case of the universal second messenger, calcium (Ca2 +) and single-wavelength dyes that increase their fluorescence upon Ca2 + binding. We validate the approach with experiments performed in aqueous solutions containing Ca2 + and Fluo4 dextran (both in its high and low affinity versions). Performing FCS experiments with tetramethylrhodamine-dextran in Xenopus laevis oocytes, we infer the corresponding free diffusion coefficients in the cytosol of these cells. Our approach can be extended to other physiologically relevant reaction-diffusion systems to quantify biophysical parameters that determine the dynamics of various variables of interest.

  14. Performance Analysis of Occurrences January 1, 2011-December 31, 2011

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ludwig, M

    2012-03-16

    This report documents the analysis of the occurrences during the period January 1, 2011 through December 31, 2011. The report compares LLNL occurrences by reporting criteria and significance category to see if LLNL is reporting occurrences along similar percentages as other DOE sites. The three-year trends are analyzed. It does not include the analysis of the causes or the lessons learned from the occurrences, as they are analyzed separately. The number and types of occurrences that LLNL reports to DOE varies over time. This variation can be attributed to normally occurring changes in frequency; DOE's or LLNL's heightened interest inmore » a particular subject area; changes in LLNL processes; or emerging problems. Since all of the DOE sites use the same reporting criteria, it is helpful to understand if LLNL is consistent with or diverging from reporting at other sites. This section compares the normalized number of occurrences reported by LLNL and other DOE sites. In order to compare LLNL occurrence reports to occurrence reports from other DOE sites, we normalized (or standardized) the data from the sites. DOE sites vary widely in their budgets, populations, and scope of work and these variations may affect reporting frequency. In addition, reports are required for a wide range of occurrence types, some of which may not be applicable to all DOE sites. For example, one occurrence reporting group is Group 3, Nuclear Safety Basis, and not all sites have nuclear operations. Because limited information is available for all sites, the sites were normalized based on best available information. Site effort hours were extracted from the DOE Computerized Accident Incident Reporting System (CAIRS) and used to normalize (or standardize) the number of occurrences by site. Effort hours are those hours that employees normally work and do not include vacation, holiday hours etc. Sites are responsible for calculating their effort hours and ensuring entry into CAIRS. Out of the 30 DOE sites that reported occurrences into ORPS during January 2011 through December 2011, 28 had effort hours available in CAIRS. Two sites had not submitted effort hours data to CAIRS as of the time data was pulled for this report. In those two cases, third quarter data was used as an estimate of fourth quarter data. The use of estimated data may introduce minor errors in the average, median, and Pearson calculations. Using the effort hours and the frequency of occurrences by site, a rate of occurrence frequency per 100 FTE workers was calculated. This rate is similar to the injury/illness frequency rate: the number of injury/illness cases per 100 FTE workers. To validate that this rate was appropriate to use, we compared the effort hours and the frequency of occurrences by site to determine if a relationship exists between the two, e.g. the more effort hours a site has, the more occurrences they tend to have. This hypothesis was tested using the Pearson Correlation Coefficient Test. The correlation coefficient measures the strength of the linear relationship between effort hours and occurrence frequency. The Pearson Correlation Coefficient Test will determine if the true correlation coefficient is equal to zero (no relationship exists), or if the correlation coefficient is not equal to zero (a relationship exists). Values approaching 1.00 show a more positive correlation. Simple linear regression was also used to display a trend line and to test if a one-way relationship exists between effort hours predicting the number of occurrences a site will have. Using the Pearson Correlation test, for the NNSA sites, effort hours and the number of occurrences are significantly and positively correlated with a correlation coefficient of 0.90, as was also seen in the previous report (correlation coefficient of 0.67). All DOE sites are positively correlated with a coefficient of 0.85. As the effort hours increase, so does the number of occurrences and vice versa. Based on the results of the simple linear regression, effort hours were found to predict the number of occurrences.« less

  15. Comparison of Performance of Eight-Year-Old Children on Three Auditory Sequential Memory Tests.

    ERIC Educational Resources Information Center

    Chermak, Gail D.; O'Connell, Vickie I.

    1981-01-01

    Twenty normal children were administered three tests of auditory sequential memory. A Pearson product-moment correlation of .50 and coefficients of determination showed all but one relationship to be nonsignificant and predictability between pairs of scores to be poor. (Author)

  16. [Electroencephalogram Feature Selection Based on Correlation Coefficient Analysis].

    PubMed

    Zhou, Jinzhi; Tang, Xiaofang

    2015-08-01

    In order to improve the accuracy of classification with small amount of motor imagery training data on the development of brain-computer interface (BCD systems, we proposed an analyzing method to automatically select the characteristic parameters based on correlation coefficient analysis. Throughout the five sample data of dataset IV a from 2005 BCI Competition, we utilized short-time Fourier transform (STFT) and correlation coefficient calculation to reduce the number of primitive electroencephalogram dimension, then introduced feature extraction based on common spatial pattern (CSP) and classified by linear discriminant analysis (LDA). Simulation results showed that the average rate of classification accuracy could be improved by using correlation coefficient feature selection method than those without using this algorithm. Comparing with support vector machine (SVM) optimization features algorithm, the correlation coefficient analysis can lead better selection parameters to improve the accuracy of classification.

  17. Quantifying the range of cross-correlated fluctuations using a q- L dependent AHXA coefficient

    NASA Astrophysics Data System (ADS)

    Wang, Fang; Wang, Lin; Chen, Yuming

    2018-03-01

    Recently, based on analogous height cross-correlation analysis (AHXA), a cross-correlation coefficient ρ×(L) has been proposed to quantify the levels of cross-correlation on different temporal scales for bivariate series. A limitation of this coefficient is that it cannot capture the full information of cross-correlations on amplitude of fluctuations. In fact, it only detects the cross-correlation at a specific order fluctuation, which might neglect some important information inherited from other order fluctuations. To overcome this disadvantage, in this work, based on the scaling of the qth order covariance and time delay L, we define a two-parameter dependent cross-correlation coefficient ρq(L) to detect and quantify the range and level of cross-correlations. This new version of ρq(L) coefficient leads to the formation of a ρq(L) surface, which not only is able to quantify the level of cross-correlations, but also allows us to identify the range of fluctuation amplitudes that are correlated in two given signals. Applications to the classical ARFIMA models and the binomial multifractal series illustrate the feasibility of this new coefficient ρq(L) . In addition, a statistical test is proposed to quantify the existence of cross-correlations between two given series. Applying our method to the real life empirical data from the 1999-2000 California electricity market, we find that the California power crisis in 2000 destroys the cross-correlation between the price and the load series but does not affect the correlation of the load series during and before the crisis.

  18. Quantifying colocalization by correlation: the Pearson correlation coefficient is superior to the Mander's overlap coefficient.

    PubMed

    Adler, Jeremy; Parmryd, Ingela

    2010-08-01

    The Pearson correlation coefficient (PCC) and the Mander's overlap coefficient (MOC) are used to quantify the degree of colocalization between fluorophores. The MOC was introduced to overcome perceived problems with the PCC. The two coefficients are mathematically similar, differing in the use of either the absolute intensities (MOC) or of the deviation from the mean (PCC). A range of correlated datasets, which extend to the limits of the PCC, only evoked a limited response from the MOC. The PCC is unaffected by changes to the offset while the MOC increases when the offset is positive. Both coefficients are independent of gain. The MOC is a confusing hybrid measurement, that combines correlation with a heavily weighted form of co-occurrence, favors high intensity combinations, downplays combinations in which either or both intensities are low and ignores blank pixels. The PCC only measures correlation. A surprising finding was that the addition of a second uncorrelated population can substantially increase the measured correlation, demonstrating the importance of excluding background pixels. Overall, since the MOC is unresponsive to substantial changes in the data and is hard to interpret, it is neither an alternative to nor a useful substitute for the PCC. The MOC is not suitable for making measurements of colocalization either by correlation or co-occurrence.

  19. Can Imaging Parameters Provide Information Regarding Histopathology in Head and Neck Squamous Cell Carcinoma? A Meta-Analysis.

    PubMed

    Surov, Alexey; Meyer, Hans Jonas; Wienke, Andreas

    2018-04-01

    Our purpose was to provide data regarding relationships between different imaging and histopathological parameters in HNSCC. MEDLINE library was screened for associations between different imaging parameters and histopathological features in HNSCC up to December 2017. Only papers containing correlation coefficients between different imaging parameters and histopathological findings were acquired for the analysis. Associations between 18 F-FDG positron emission tomography (PET) and KI 67 were reported in 8 studies (236 patients). The pooled correlation coefficient was 0.20 (95% CI = [-0.04; 0.44]). Furthermore, in 4 studies (64 patients), associations between 18 F-fluorothymidine PET and KI 67 were analyzed. The pooled correlation coefficient between SUV max and KI 67 was 0.28 (95% CI = [-0.06; 0.94]). In 2 studies (23 patients), relationships between KI 67 and dynamic contrast-enhanced magnetic resonance imaging were reported. The pooled correlation coefficient between K trans and KI 67 was -0.68 (95% CI = [-0.91; -0.44]). Two studies (31 patients) investigated correlation between apparent diffusion coefficient (ADC) and KI 67. The pooled correlation coefficient was -0.61 (95% CI = [-0.84; -0.38]). In 2 studies (117 patients), relationships between 18 F-FDG PET and p53 were analyzed. The pooled correlation coefficient was 0.0 (95% CI = [-0.87; 0.88]). There were 3 studies (48 patients) that investigated associations between ADC and tumor cell count in HNSCC. The pooled correlation coefficient was -0.53 (95% CI = [-0.74; -0.32]). Associations between 18 F-FDG PET and HIF-1α were investigated in 3 studies (72 patients). The pooled correlation coefficient was 0.44 (95% CI = [-0.20; 1.08]). ADC may predict cell count and proliferation activity, and SUV max may predict expression of HIF-1α in HNSCC. SUV max cannot be used as surrogate marker for expression of KI 67 and p53. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  20. Spatial resolution of pace mapping of idiopathic ventricular tachycardia/ectopy originating in the right ventricular outflow tract.

    PubMed

    Bogun, Frank; Taj, Majid; Ting, Michael; Kim, Hyungjin Myra; Reich, Stephen; Good, Eric; Jongnarangsin, Krit; Chugh, Aman; Pelosi, Frank; Oral, Hakan; Morady, Fred

    2008-03-01

    Pace mapping has been used to identify the site of origin of focal ventricular arrhythmias. The spatial resolution of pace mapping has not been adequately quantified using currently available three-dimensional mapping systems. The purpose of this study was to determine the spatial resolution of pace mapping in patients with idiopathic ventricular tachycardia or premature ventricular contractions originating in the right ventricular outflow tract. In 16 patients with idiopathic ventricular tachycardia/ectopy from the right ventricular outflow tract, comparisons and classifications of pace maps were performed by two observers (good pace map: match >10/12 leads; inadequate pace map: match < or =10/12 leads) and a customized MATLAB 6.0 program (assessing correlation coefficient and normalized root mean square of the difference (nRMSd) between test and template signals). With an electroanatomic mapping system, the correlation coefficient of each pace map was correlated with the distance between the pacing site and the effective ablation site. The endocardial area within the 10-ms activation isochrone was measured. The ablation procedure was effective in all patients. Sites with good pace maps had a higher correlation coefficient and lower nRMSd than sites with inadequate pace maps (correlation coefficient: 0.96 +/- 0.03 vs 0.76 +/- 0.18, P <.0001; nRMSd: 0.41 +/- 0.16 vs 0.89 +/- 0.39, P <.0001). Using receiver operating characteristic curves, appropriate cutoff values were >0.94 for correlation coefficient (sensitivity 81%, specificity 89%) and < or =0.54 for nRMSd (sensitivity 76%, specificity 80%). Good pace maps were located a mean of 7.3 +/- 5.0 mm from the effective ablation site and had a mean activation time of -24 +/- 7 ms. However, in 3 (18%) of 16 patients, the best pace map was inadequate at the effective ablation site, with an endocardial activation time at these sites of -25 +/- 12 ms. Pace maps with correlation coefficient > or =0.94 were confined to an area of 1.8 +/- 0.6 cm2. The 10-ms isochrone measured 1.2 +/- 0.7 cm2. The spatial resolution of a good pace map for targeting ventricular tachycardia/ectopy is 1.8 cm2 in the right ventricular outflow tract and therefore is inferior to the spatial resolution of activation mapping as assessed by isochronal activation. In approximately 20% of patients, pace mapping is unreliable in identifying the site of origin, possibly due a deeper site of origin and preferential conduction via fibers connecting the focus to the endocardial surface.

  1. [Environmental responses of four urban tree species transpiration in northern China].

    PubMed

    Chen, Li-xin; Li, Zhan-dong; Zhang, Zhi-qiang; Zhang, Wen-juan; Zhang, Xiao-fang; Dong, Ke-yu; Wang, Guo-yu

    2009-12-01

    By using thermal dissipation probes (TDP), this paper monitored the sap flow of four tree species (Cedrus deodara, Zelkova schneideriana, Euonymus bungeanus, and Metasequoia glyptostroboides) at the Laodong Park in Dalian City from June to August 2008, and the soil moisture content and micrometeorological variables were mehsured simultaneously. Due to the absence of water-stress in the habitat, the sap flow of all sampled trees had no significant correlation with soil moisture content (R2 < 0.050, P > 0.211, n=1296). The correlation coefficient between solar radiation and sap flow reached 0.624-0.773 (P = 0.00, n=1296) despite the existing hysteresis. Solar radiation had major effect (R2 > 0.700, P < 0.05) during early morning (5:00-8:00) and late afternoon (18:00-20:00) when undergoing dramatic changes. As the main factor determining nighttime sap flow (R2 > 0.660, P < 0.05, n=1872), vapor pressure deficit (VPD) had a correlation coefficient as high as 0.650-0.823 (P = 0.00, n=1296) with the sap flow in whole-day scale. Meanwhile, the models constructed on the basis of VPD were able to explain 90% of daily sap flow change (P = 0.00). The correlation coefficient between sap flow and wind speed was relatively smaller than the previous two (R2 < 0.380, P = 0.00, n=1296), though showing significant correlation in affecting sap flow. Observations also detected the saturation phenomenon of sap flow to the environmental demands.

  2. Can poison control data be used for pharmaceutical poisoning surveillance?

    PubMed

    Naun, Christopher A; Olsen, Cody S; Dean, J Michael; Olson, Lenora M; Cook, Lawrence J; Keenan, Heather T

    2011-05-01

    To determine the association between the frequencies of pharmaceutical exposures reported to a poison control center (PCC) and those seen in the emergency department (ED). A statewide population-based retrospective comparison of frequencies of ED pharmaceutical poisonings with frequencies of pharmaceutical exposures reported to a regional PCC. ED poisonings, identified by International Classification of Diseases, Version 9 (ICD-9) codes, were grouped into substance categories. Using a reproducible algorithm facilitated by probabilistic linkage, codes from the PCC classification system were mapped into the same categories. A readily identifiable subset of PCC calls was selected for comparison. Correlations between frequencies of quarterly exposures by substance categories were calculated using Pearson correlation coefficients and partial correlation coefficients with adjustment for seasonality. PCC reported exposures correlated with ED poisonings in nine of 10 categories. Partial correlation coefficients (r(p)) indicated strong associations (r(p)>0.8) for three substance categories that underwent large changes in their incidences (opiates, benzodiazepines, and muscle relaxants). Six substance categories were moderately correlated (r(p)>0.6). One category, salicylates, showed no association. Limitations Imperfect overlap between ICD-9 and PCC codes may have led to miscategorization. Substances without changes in exposure frequency have inadequate variability to detect association using this method. PCC data are able to effectively identify trends in poisonings seen in EDs and may be useful as part of a pharmaceutical poisoning surveillance system. The authors developed an algorithm-driven technique for mapping American Association of Poison Control Centers codes to ICD-9 codes and identified a useful subset of poison control exposures for analysis.

  3. Correlation of ADC value with pathologic indexes in colorectal tumor homografts in Balb/c mouse.

    PubMed

    Li, Xiaojun; Jiang, Hongnan; Niu, Jinliang; Zheng, Ying

    2014-08-01

    Noninvasive diffusion-weighted magnetic resonance imaging (DWI) is a well-studied MR imaging technique for quantifying water diffusion especially in tumor area. The correlation between apparent diffusion coefficient (ADC) value and apoptosis or proliferation is not clear by now. This study aimed to investigate whether DWI-ADC value could be used as an imaging marker related with pathologic indexes of tumors. A total of 30 Balb/c mice with HT29 colorectal carcinoma were subjected to DWI and histologic analysis. The percentage of ADC changes and the apoptotic and proliferating indexes were calculated at predefined time points. Kolmogorov-Smirnov distances were considered to determine whether the percentage of ADC changes, and the apoptotic and proliferating indexes were normally distributed. An independent-samples t-test was used to analyze the difference between apoptotic and proliferating indexes in the two groups. THERE WAS A STATISTICALLY SIGNIFICANT DIFFERENCE IN PROLIFERATING INDEX BETWEEN THE RADIOTHERAPY AND CONTROL GROUPS (MEAN PROLIFERATING INDEX: 49.27% vs. 83.09%), and there was a statistically significant difference in apoptotic index between the two groups (mean apoptotic index: 37.7% vs. 2.71%). A significant positive correlation was found between the percentage of ADC changes of the viable tissue and apoptotic index. Pearson's correlation coefficient was 0.655 (P=0.015). A significant negative correlation was found between the percentage of ADC changes of the viable tissue and ki-67 proliferation index. Pearson's correlation coefficient was 0.734 (P<0.001). Our results suggest that ADC value may be used in measurement of cell apoptotic and proliferating indexes in colorectal carcinoma.

  4. A novel coefficient for detecting and quantifying asymmetry of California electricity market based on asymmetric detrended cross-correlation analysis.

    PubMed

    Wang, Fang

    2016-06-01

    In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρDXA, contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.

  5. Detecting PM2.5's Correlations between Neighboring Cities Using a Time-Lagged Cross-Correlation Coefficient.

    PubMed

    Wang, Fang; Wang, Lin; Chen, Yuming

    2017-08-31

    In order to investigate the time-dependent cross-correlations of fine particulate (PM2.5) series among neighboring cities in Northern China, in this paper, we propose a new cross-correlation coefficient, the time-lagged q-L dependent height crosscorrelation coefficient (denoted by p q (τ, L)), which incorporates the time-lag factor and the fluctuation amplitude information into the analogous height cross-correlation analysis coefficient. Numerical tests are performed to illustrate that the newly proposed coefficient ρ q (τ, L) can be used to detect cross-correlations between two series with time lags and to identify different range of fluctuations at which two series possess cross-correlations. Applying the new coefficient to analyze the time-dependent cross-correlations of PM2.5 series between Beijing and the three neighboring cities of Tianjin, Zhangjiakou, and Baoding, we find that time lags between the PM2.5 series with larger fluctuations are longer than those between PM2.5 series withsmaller fluctuations. Our analysis also shows that cross-correlations between the PM2.5 series of two neighboring cities are significant and the time lags between two PM2.5 series of neighboring cities are significantly non-zero. These findings providenew scientific support on the view that air pollution in neighboring cities can affect one another not simultaneously but with a time lag.

  6. Determination of oleanolic acid in human plasma and its association with olive oil intake in healthy Spanish adults within the EPIC Spain cohort study.

    PubMed

    Buckland, Genevieve; Pastor, Antoni; Lujan-Barroso, Leila; Gonzalez, Carlos Alberto; Travier, Noemie; Amiano, Pilar; Huerta, José María; Agudo, Antonio; Navarro, Carmen; Chirlaque, María Dolores; Sánchez, Maria-José; Rodríguez-Barranco, Miguel; Barricarte, Aurelio; Ardanaz, Eva; Dorronsoro, Miren; Molinuevo, Amaia; Quirós, José Ramón; de la Torre, Rafael

    2017-08-01

    Oleanolic acid (OA) is an important triterpenic compound found in olive oil, however little is known about its concentrations in human plasma. We aimed to determine plasma OA levels in a healthy Spanish population and compare them with estimates of dietary olive oil intake. The final study sample included 141 individuals randomly selected from the European Prospective Investigation into Cancer and Nutrition Spanish cohort. Dietary olive oil intake was estimated using validated dietary history questionnaires. OA concentrations were determined in plasma (from the participants' stored blood samples) using a HPLC-MS method. Correlation coefficients between OA and olive oil intake were calculated, adjusting for center; sex; age; consumption of olives, apples, grapes, and red wine; and fasting state. The mean OA concentration in olive oil nonconsumers was 0.72 ng/mL (SD 0.82), while in the high olive oil intake group it was 1.32 ng/mL (SD 1.14). The fully adjusted partial Spearman correlations coefficients reached 0.36 (p-value < 0.001) overall, varying minimally by sex and fasting state. This is the first study providing steady-state concentrations of triterpenes in humans. The results show that there was low-to-moderate correlation between OA concentrations and olive oil intake in this population. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Experimental and Analytical Investigation of the Coolant Flow Characteristics in Cooled Turbine Airfoils

    NASA Technical Reports Server (NTRS)

    Damerow, W. P.; Murtaugh, J. P.; Burggraf, F.

    1972-01-01

    The flow characteristics of turbine airfoil cooling system components were experimentally investigated. Flow models representative of leading edge impingement, impingement with crossflow (midchord cooling), pin fins, feeder supply tube, and a composite model of a complete airfoil flow system were tested. Test conditions were set by varying pressure level to cover the Mach number and Reynolds number range of interest in advanced turbine applications. Selected geometrical variations were studied on each component model to determine these effects. Results of these tests were correlated and compared with data available in the literature. Orifice flow was correlated in terms of discharge coefficients. For the leading edge model this was found to be a weak function of hole Mach number and orifice-to-impinged wall spacing. In the impingement with crossflow tests, the discharge coefficient was found to be constant and thus independent of orifice Mach number, Reynolds number, crossflow rate, and impingement geometry. Crossflow channel pressure drop showed reasonable agreement with a simple one-dimensional momentum balance. Feeder tube orifice discharge coefficients correlated as a function of orifice Mach number and the ratio of the orifice-to-approach velocity heads. Pin fin data was correlated in terms of equivalent friction factor, which was found to be a function of Reynolds number and pin spacing but independent of pin height in the range tested.

  8. Limits of the memory coefficient in measuring correlated bursts

    NASA Astrophysics Data System (ADS)

    Jo, Hang-Hyun; Hiraoka, Takayuki

    2018-03-01

    Temporal inhomogeneities in event sequences of natural and social phenomena have been characterized in terms of interevent times and correlations between interevent times. The inhomogeneities of interevent times have been extensively studied, while the correlations between interevent times, often called correlated bursts, are far from being fully understood. For measuring the correlated bursts, two relevant approaches were suggested, i.e., memory coefficient and burst size distribution. Here a burst size denotes the number of events in a bursty train detected for a given time window. Empirical analyses have revealed that the larger memory coefficient tends to be associated with the heavier tail of the burst size distribution. In particular, empirical findings in human activities appear inconsistent, such that the memory coefficient is close to 0, while burst size distributions follow a power law. In order to comprehend these observations, by assuming the conditional independence between consecutive interevent times, we derive the analytical form of the memory coefficient as a function of parameters describing interevent time and burst size distributions. Our analytical result can explain the general tendency of the larger memory coefficient being associated with the heavier tail of burst size distribution. We also find that the apparently inconsistent observations in human activities are compatible with each other, indicating that the memory coefficient has limits to measure the correlated bursts.

  9. Correlation Coefficients: Appropriate Use and Interpretation.

    PubMed

    Schober, Patrick; Boer, Christa; Schwarte, Lothar A

    2018-05-01

    Correlation in the broadest sense is a measure of an association between variables. In correlated data, the change in the magnitude of 1 variable is associated with a change in the magnitude of another variable, either in the same (positive correlation) or in the opposite (negative correlation) direction. Most often, the term correlation is used in the context of a linear relationship between 2 continuous variables and expressed as Pearson product-moment correlation. The Pearson correlation coefficient is typically used for jointly normally distributed data (data that follow a bivariate normal distribution). For nonnormally distributed continuous data, for ordinal data, or for data with relevant outliers, a Spearman rank correlation can be used as a measure of a monotonic association. Both correlation coefficients are scaled such that they range from -1 to +1, where 0 indicates that there is no linear or monotonic association, and the relationship gets stronger and ultimately approaches a straight line (Pearson correlation) or a constantly increasing or decreasing curve (Spearman correlation) as the coefficient approaches an absolute value of 1. Hypothesis tests and confidence intervals can be used to address the statistical significance of the results and to estimate the strength of the relationship in the population from which the data were sampled. The aim of this tutorial is to guide researchers and clinicians in the appropriate use and interpretation of correlation coefficients.

  10. Relationship of salivary and plasma cortisol levels in preterm infants: results of a prospective observational study and systematic review of the literature.

    PubMed

    Maas, Christoph; Ringwald, Christine; Weber, Karin; Engel, Corinna; Poets, Christian F; Binder, Gerhard; Bassler, Dirk

    2014-01-01

    (1) To investigate the relationship of salivary and plasma cortisol levels in preterm infants with a focus on the usability of salivary cortisol in diagnostic work-up of infants at risk of adrenal insufficiency. (2) To perform a systematic review addressing this question. Clinical study: We conducted a prospective observational single-center study in preterm infants. We analyzed plasma and saliva cortisol concentrations by enzyme immunoassay. Correlation analysis was used to determine the relation between salivary and plasma cortisol levels and the agreement of the measurement methods was analyzed according to Bland-Altman. Systematic review: A systematic literature search (PubMed and Embase) on the relationship of salivary and plasma cortisol levels in neonates was performed in November 2012. Clinical study: We enrolled 58 preterm infants (median (interquartile range) gestational age at birth was 31.4 (28.1-32.7) weeks, birth weight 1,340 (974-1,745) g, respectively). Correlation analyses revealed a relationship of plasma cortisol and salivary cortisol levels. Rank correlation coefficient was 0.6. Estimating plasma cortisol levels based on measured salivary cortisol levels showed poor agreement of the two methods for determining plasma cortisol levels (direct and via salivary cortisol). Sensitivity and specificity of salivary cortisol for the detection of adrenal insufficiency were 0.66 and 0.62, respectively. Systematic review: Six studies in preterm infants and term neonates depicting the correlation of salivary and plasma cortisol were identified with a range of saliva-plasma correlation coefficients from 0.44 to 0.83. Substitution of plasma cortisol by salivary cortisol determination cannot be recommended in preterm infants because of unsatisfactory agreement between methods.

  11. Repeatability of Computerized Tomography-Based Anthropomorphic Measurements of Frailty in Patients With Pulmonary Fibrosis Undergoing Lung Transplantation.

    PubMed

    McClellan, Taylor; Allen, Brian C; Kappus, Matthew; Bhatti, Lubna; Dafalla, Randa A; Snyder, Laurie D; Bashir, Mustafa R

    To determine interreader and intrareader repeatability and correlations among measurements of computerized tomography-based anthropomorphic measurements in patients with pulmonary fibrosis undergoing lung transplantation. This was an institutional review board-approved, Health Insurance Portability and Accountability Act-compliant retrospective study of 23 randomly selected subjects (19 male and 4 female; median age = 69 years; range: 66-77 years) with idiopathic pulmonary fibrosis undergoing pulmonary transplantation, who had also undergone preoperative thoracoabdominal computerized tomography. Five readers of varying imaging experience independently performed the following cross-sectional area measurements at the inferior endplate of the L3 vertebral body: right and left psoas muscles, right and left paraspinal muscles, total abdominal musculature, and visceral and subcutaneous fat. The following measurements were obtained at the inferior endplate of T6: right and left paraspinal muscles with and without including the trapezius muscles and subcutaneous fat. Three readers repeated all measurements to assess intrareader repeatability. Intrareader repeatability was nearly perfect (interclass correlation coefficients = 0.99, P < 0.001). Interreader agreement was excellent across all 5 readers (interclass correlation coefficients: 0.71-0.99, P < 0.001). Coefficients of variance between measures ranged from 3.2%-6.8% for abdominal measurements, but were higher for thoracic measurements, up to 23.9%. Correlation between total paraspinal and total psoas muscle area was strong (r 2 = 0.67, P < 0.001). Thoracic and abdominal musculature had a weaker correlation (r 2 = 0.35-0.38, P < 0.001). Measures of thoracic and abdominal muscle and fat area are highly repeatable in patients with pulmonary fibrosis undergoing lung transplantation. Measures of muscle area are strongly correlated among abdominal locations, but inversely correlated between abdominal and thoracic locations. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Standardized uptake value and apparent diffusion coefficient of endometrial cancer evaluated with integrated whole-body PET/MR: Correlation with pathological prognostic factors.

    PubMed

    Shih, I-Lun; Yen, Ruoh-Fang; Chen, Chi-An; Chen, Bang-Bin; Wei, Shwu-Yuan; Chang, Wen-Chun; Sheu, Bor-Ching; Cheng, Wen-Fang; Tseng, Yao-Hui; Chen, Xin-Jia; Chen, Chi-Hau; Wei, Lin-Hung; Chiang, Ying-Cheng; Torng, Pao-Ling; Yen, Men-Luh; Shih, Tiffany Ting-Fang

    2015-12-01

    To evaluate the correlation between maximum standardized uptake value (SUVmax ) and minimum apparent diffusion coefficient (ADCmin ) of endometrial cancer derived from an integrated positron emission tomography / magnetic resonance (PET/MR) system and to determine their correlation with pathological prognostic factors. This prospective study was approved by the Institutional Review Board of the hospital, and informed consent was obtained. Between April and December 2014, 47 consecutive patients with endometrial cancer were enrolled and underwent simultaneous PET/MR examinations before surgery. Thirty-six patients with measurable tumors on PET/MR were included for image analysis. Pearson's correlation coefficient was used to evaluate the correlation between SUVmax and ADCmin of the tumors. The Mann-Whitney U-test was utilized to evaluate relationships between these two imaging biomarkers and pathological prognostic factors. The mean SUVmax and ADCmin were 14.7 ± 7.1 and 0.48 ± 0.13 × 10(-3) mm(2) /s, respectively. A significant inverse correlation was found between SUVmax and ADCmin (r = -0.53; P = 0.001). SUVmax was significantly higher in tumors with advanced stage, deep myometrial invasion, cervical invasion, lymphovascular space involvement, and lymph node metastasis (P < 0.05). ADCmin was lower in tumors with higher grade, advanced stage, and cervical invasion (P < 0.05). The ratio of SUVmax to ADCmin was higher in tumors with higher grade, advanced stage, deep myometrial invasion, cervical invasion, lymphovascular space involvement, and lymph node metastasis (P < 0.05). SUVmax and ADCmin of endometrial cancer derived from integrated PET/MR are inversely correlated and are associated with pathological prognostic factors. © 2015 Wiley Periodicals, Inc.

  13. Improving Reading Achievement in High Poverty, Rural Schools

    ERIC Educational Resources Information Center

    Tufts, Janet

    2017-01-01

    Purpose: The purpose of this quantitative study was to determine what correlation exists between a student's poverty coefficient and the daily number of minutes provided for independent reading and third grade reading achievement level as measured by California Assessment of Student Performance and Progress (CAASPP) in small, rural school…

  14. The Predictive Validity of Dynamic Assessment: A Review

    ERIC Educational Resources Information Center

    Caffrey, Erin; Fuchs, Douglas; Fuchs, Lynn S.

    2008-01-01

    The authors report on a mixed-methods review of 24 studies that explores the predictive validity of dynamic assessment (DA). For 15 of the studies, they conducted quantitative analyses using Pearson's correlation coefficients. They descriptively examined the remaining studies to determine if their results were consistent with findings from the…

  15. Fine and hyperfine collisional excitation of C6H by He

    NASA Astrophysics Data System (ADS)

    Walker, Kyle M.; Lique, François; Dawes, Richard

    2018-01-01

    Hydrogenated carbon chains have been detected in interstellar and circumstellar media and accurate modelling of their abundances requires collisional excitation rate coefficients with the most abundant species. Among them, the C6H molecule is one of the most abundant towards many lines of sight. Hence, we determined fine and hyperfine-resolved rate coefficients for the excitation of C6H(X2Π) due to collisions with He. We present the first interaction potential energy surface for the C6H-He system, obtained from highly correlated ab initio calculations and characterized by a large anisotropy due to the length of the molecule. We performed dynamical calculations for transitions among the first fine structure levels (up to J = 30.5) of both spin-orbit manifolds of C6H using the close-coupling method, and rate coefficients are determined for temperatures ranging from 5 to 100 K. The largest rate coefficients for even ΔJ transitions conserve parity, while parity-breaking rate coefficients are favoured for odd ΔJ. Spin-orbit changing rate coefficients are several orders of magnitude lower than transitions within a single manifold. State-to-state hyperfine-resolved cross-sections for the first levels (up to J = 13.5) in the Ω = 3/2 spin-orbit manifold are deduced using recoupling techniques. Rate coefficients are obtained and the propensity rule ΔJ = ΔF is seen. These new data will help determine the abundance of C6H in astrophysical environments such as cold dense molecular clouds, star-forming regions and circumstellar envelopes, and will help in the interpretation of the puzzling C6H-/C6H abundance ratios deduced from observations.

  16. Epidural Catheter Placement in Morbidly Obese Parturients with the Use of an Epidural Depth Equation prior to Ultrasound Visualization

    PubMed Central

    Singh, Sukhdip; Wirth, Keith M.; Phelps, Amy L.; Badve, Manasi H.; Shah, Tanmay H.; Vallejo, Manuel C.

    2013-01-01

    Background. Previously, Balki determined the Pearson correlation coefficient with the use of ultrasound (US) was 0.85 in morbidly obese parturients. We aimed to determine if the use of the epidural depth equation (EDE) in conjunction with US can provide better clinical correlation in estimating the distance from the skin to the epidural space in morbidly obese parturients. Methods. One hundred sixty morbidly obese (≥40 kg/m2) parturients requesting labor epidural analgesia were enrolled. Before epidural catheter placement, EDE was used to estimate depth to the epidural space. This estimation was used to help visualize the epidural space with the transverse and midline longitudinal US views and to measure depth to epidural space. The measured epidural depth was made available to the resident trainee before needle insertion. Actual needle depth (ND) to the epidural space was recorded. Results. Pearson's correlation coefficients comparing actual (ND) versus US estimated depth to the epidural space in the longitudinal median and transverse planes were 0.905 (95% CI: 0.873 to 0.929) and 0.899 (95% CI: 0.865 to 0.925), respectively. Conclusion. Use of the epidural depth equation (EDE) in conjunction with the longitudinal and transverse US views results in better clinical correlation than with the use of US alone. PMID:23983645

  17. Correlates of anxiety and depression among patients with type 2 diabetes mellitus.

    PubMed

    Balhara, Yatan Pal Singh; Sagar, Rajesh

    2011-07-01

    Research has established the relation between diabetes and depression. Both diabetes and anxiety/depression are independently associated with increased morbidity and mortality. The present study aims at assessing the prevalence of anxiety/depression among outpatients receiving treatment for type 2 diabetes. The study was conducted in the endocrinology outpatient department of an urban tertiary care center. The instruments used included a semi-structured questionnaire, HbA1c levels, fasting blood glucose and postprandial blood glucose, Brief Patient Health Questionnaire, and Hospital Anxiety and Depression Scale (HADS). Analysis was carried out using the SPSS version 16.0. Pearson's correlation coefficient was calculated to find out the correlations. ANOVA was carried out for the in between group comparisons. There was a significant correlation between the HADS-Anxiety scale and Body Mass Index (BMI) with a correlation coefficient of 0.34 (P = 0.008). Also, a significant correlation existed between HADS-Depression scale and BMI (correlation coefficient, 0.36; P = 0.004). Significant correlation were observed between the duration of daily physical exercise and HADS-Anxiety (coefficient of correlation, -0.25; P = 0.04) scores. HADS-Anxiety scores were found to be related to HbA1c levels (correlation-coefficient, 0.41; P = 0.03) and postprandial blood glucose levels (correlation-coefficient, 0.51; P = 0.02). Monitoring of biochemical parameters like HbA1c and postprandial blood glucose levels and BMI could be a guide to development of anxiety in these patients. Also, physical exercise seems to have a protective effect on anxiety in those with type 2 diabetes mellitus.

  18. Second derivative synchronous fluorimetric method for simultaneous determination of harman and norharman in coffee samples

    NASA Astrophysics Data System (ADS)

    Wabaidur, Saikh Mohammad; Lee, Sang Hak; Alothman, Zeid Abdullah; Siddiqui, Masoom Raza; Alam, Seikh Mafiz

    2013-06-01

    The simultaneous determination of harman and norharman using second derivative synchronous fluorescence method has been developed based on their natural fluorescence. Due to their similar molecular structures, it is difficult to determine them simultaneously in the mixture using conventional fluorimetry. Overlapping of fluorescence spectra was resolved by using a constant second derivative synchronous fluorimetry. The derivative synchronous spectrum, maintaining a constant difference of Δλ = 150 nm between emission and excitation for both the compounds, has been selected for the analysis. The range of application is between 0.182 and 18.2 μg/mL (correlation coefficient, R = 0.9982) for harman and between 0.504 and 16.8 μg/mL (correlation coefficient, R = 0.9962) for norharman. The recovery ranges of 98.5-101.1% for harman and 97.5-99.1% for norharman from their synthetic mixture was reported. The detection limits are 0.016 μg/mL and 0.038 μg/mL for harman and norharman, respectively. Similarly, the quantitation limit of the two compounds was found to be 0.049 and 0.109 μg/mL, respectively. The method was applied to the simultaneous determination of both compounds in coffee samples with satisfactory results.

  19. Second derivative synchronous fluorimetric method for simultaneous determination of harman and norharman in coffee samples.

    PubMed

    Wabaidur, Saikh Mohammad; Lee, Sang Hak; Alothman, Zeid Abdullah; Siddiqui, Masoom Raza; Alam, Seikh Mafiz

    2013-06-01

    The simultaneous determination of harman and norharman using second derivative synchronous fluorescence method has been developed based on their natural fluorescence. Due to their similar molecular structures, it is difficult to determine them simultaneously in the mixture using conventional fluorimetry. Overlapping of fluorescence spectra was resolved by using a constant second derivative synchronous fluorimetry. The derivative synchronous spectrum, maintaining a constant difference of Δλ=150 nm between emission and excitation for both the compounds, has been selected for the analysis. The range of application is between 0.182 and 18.2 μg/mL (correlation coefficient, R=0.9982) for harman and between 0.504 and 16.8 μg/mL (correlation coefficient, R=0.9962) for norharman. The recovery ranges of 98.5-101.1% for harman and 97.5-99.1% for norharman from their synthetic mixture was reported. The detection limits are 0.016 μg/mL and 0.038 μg/mL for harman and norharman, respectively. Similarly, the quantitation limit of the two compounds was found to be 0.049 and 0.109 μg/mL, respectively. The method was applied to the simultaneous determination of both compounds in coffee samples with satisfactory results. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Prediction of friction coefficients for gases

    NASA Technical Reports Server (NTRS)

    Taylor, M. F.

    1969-01-01

    Empirical relations are used for correlating laminar and turbulent friction coefficients for gases, with large variations in the physical properties, flowing through smooth tubes. These relations have been used to correlate friction coefficients for hydrogen, helium, nitrogen, carbon dioxide and air.

  1. QSPR modeling of octanol/water partition coefficient of antineoplastic agents by balance of correlations.

    PubMed

    Toropov, Andrey A; Toropova, Alla P; Raska, Ivan; Benfenati, Emilio

    2010-04-01

    Three different splits into the subtraining set (n = 22), the set of calibration (n = 21), and the test set (n = 12) of 55 antineoplastic agents have been examined. By the correlation balance of SMILES-based optimal descriptors quite satisfactory models for the octanol/water partition coefficient have been obtained on all three splits. The correlation balance is the optimization of a one-variable model with a target function that provides both the maximal values of the correlation coefficient for the subtraining and calibration set and the minimum of the difference between the above-mentioned correlation coefficients. Thus, the calibration set is a preliminary test set. Copyright (c) 2009 Elsevier Masson SAS. All rights reserved.

  2. C-Depth Method to Determine Diffusion Coefficient and Partition Coefficient of PCB in Building Materials.

    PubMed

    Liu, Cong; Kolarik, Barbara; Gunnarsen, Lars; Zhang, Yinping

    2015-10-20

    Polychlorinated biphenyls (PCBs) have been found to be persistent in the environment and possibly harmful. Many buildings are characterized with high PCB concentrations. Knowledge about partitioning between primary sources and building materials is critical for exposure assessment and practical remediation of PCB contamination. This study develops a C-depth method to determine diffusion coefficient (D) and partition coefficient (K), two key parameters governing the partitioning process. For concrete, a primary material studied here, relative standard deviations of results among five data sets are 5%-22% for K and 42-66% for D. Compared with existing methods, C-depth method overcomes the inability to obtain unique estimation for nonlinear regression and does not require assumed correlations for D and K among congeners. Comparison with a more sophisticated two-term approach implies significant uncertainty for D, and smaller uncertainty for K. However, considering uncertainties associated with sampling and chemical analysis, and impact of environmental factors, the results are acceptable for engineering applications. This was supported by good agreement between model prediction and measurement. Sensitivity analysis indicated that effective diffusion distance, contacting time of materials with primary sources, and depth of measured concentrations are critical for determining D, and PCB concentration in primary sources is critical for K.

  3. A solid-state thin-film Ag/AgCl reference electrode coated with graphene oxide and its use in a pH sensor.

    PubMed

    Kim, Tae Yong; Hong, Sung A; Yang, Sung

    2015-03-17

    In this study, we describe a novel solid-state thin-film Ag/AgCl reference electrode (SSRE) that was coated with a protective layer of graphene oxide (GO). This layer was prepared by drop casting a solution of GO on the Ag/AgCl thin film. The potential differences exhibited by the SSRE were less than 2 mV for 26 days. The cyclic voltammograms of the SSRE were almost similar to those of a commercial reference electrode, while the diffusion coefficient of Fe(CN)63- as calculated from the cathodic peaks of the SSRE was 6.48 × 10-6 cm2/s. The SSRE was used in conjunction with a laboratory-made working electrode to determine its suitability for practical use. The average pH sensitivity of this combined sensor was 58.5 mV/pH in the acid-to-base direction; the correlation coefficient was greater than 0.99. In addition, an integrated pH sensor that included the SSRE was packaged in a secure digital (SD) card and tested. The average sensitivity of the chip was 56.8 mV/pH, with the correlation coefficient being greater than 0.99. In addition, a pH sensing test was also performed by using a laboratory-made potentiometer, which showed a sensitivity of 55.4 mV/pH, with the correlation coefficient being greater than 0.99.

  4. The Robustness of Designs for Trials with Nested Data against Incorrect Initial Intracluster Correlation Coefficient Estimates

    ERIC Educational Resources Information Center

    Korendijk, Elly J. H.; Moerbeek, Mirjam; Maas, Cora J. M.

    2010-01-01

    In the case of trials with nested data, the optimal allocation of units depends on the budget, the costs, and the intracluster correlation coefficient. In general, the intracluster correlation coefficient is unknown in advance and an initial guess has to be made based on published values or subject matter knowledge. This initial estimate is likely…

  5. Quantifying Errors in Jet Noise Research Due to Microphone Support Reflection

    NASA Technical Reports Server (NTRS)

    Nallasamy, Nambi; Bridges, James

    2002-01-01

    The reflection coefficient of a microphone support structure used insist noise testing is documented through tests performed in the anechoic AeroAcoustic Propulsion Laboratory. The tests involve the acquisition of acoustic data from a microphone mounted in the support structure while noise is generated from a known broadband source. The ratio of reflected signal amplitude to the original signal amplitude is determined by performing an auto-correlation function on the data. The documentation of the reflection coefficients is one component of the validation of jet noise data acquired using the given microphone support structure. Finally. two forms of acoustic material were applied to the microphone support structure to determine their effectiveness in reducing reflections which give rise to bias errors in the microphone measurements.

  6. The effect of rare alleles on estimated genomic relationships from whole genome sequence data.

    PubMed

    Eynard, Sonia E; Windig, Jack J; Leroy, Grégoire; van Binsbergen, Rianne; Calus, Mario P L

    2015-03-12

    Relationships between individuals and inbreeding coefficients are commonly used for breeding decisions, but may be affected by the type of data used for their estimation. The proportion of variants with low Minor Allele Frequency (MAF) is larger in whole genome sequence (WGS) data compared to Single Nucleotide Polymorphism (SNP) chips. Therefore, WGS data provide true relationships between individuals and may influence breeding decisions and prioritisation for conservation of genetic diversity in livestock. This study identifies differences between relationships and inbreeding coefficients estimated using pedigree, SNP or WGS data for 118 Holstein bulls from the 1000 Bull genomes project. To determine the impact of rare alleles on the estimates we compared three scenarios of MAF restrictions: variants with a MAF higher than 5%, variants with a MAF higher than 1% and variants with a MAF between 1% and 5%. We observed significant differences between estimated relationships and, although less significantly, inbreeding coefficients from pedigree, SNP or WGS data, and between MAF restriction scenarios. Computed correlations between pedigree and genomic relationships, within groups with similar relationships, ranged from negative to moderate for both estimated relationships and inbreeding coefficients, but were high between estimates from SNP and WGS (0.49 to 0.99). Estimated relationships from genomic information exhibited higher variation than from pedigree. Inbreeding coefficients analysis showed that more complete pedigree records lead to higher correlation between inbreeding coefficients from pedigree and genomic data. Finally, estimates and correlations between additive genetic (A) and genomic (G) relationship matrices were lower, and variances of the relationships were larger when accounting for allele frequencies than without accounting for allele frequencies. Using pedigree data or genomic information, and including or excluding variants with a MAF below 5% showed significant differences in relationship and inbreeding coefficient estimates. Estimated relationships and inbreeding coefficients are the basis for selection decisions. Therefore, it can be expected that using WGS instead of SNP can affect selection decision. Inclusion of rare variants will give access to the variation they carry, which is of interest for conservation of genetic diversity.

  7. A correlational analysis of the effects of changing environmental conditions on the NR atomic hydrogen maser

    NASA Technical Reports Server (NTRS)

    Dragonette, Richard A.; Suter, Joseph J.

    1992-01-01

    An extensive statistical analysis has been undertaken to determine if a correlation exists between changes in an NR atomic hydrogen maser's frequency offset and changes in environmental conditions. Correlation analyses have been performed comparing barometric pressure, humidity, and temperature with maser frequency offset as a function of time for periods ranging from 5.5 to 17 days. Semipartial correlation coefficients as large as -0.9 have been found between barometric pressure and maser frequency offset. Correlation between maser frequency offset and humidity was small compared to barometric pressure and unpredictable. Analysis of temperature data indicates that in the most current design, temperature does not significantly affect maser frequency offset.

  8. Statistical methods for astronomical data with upper limits. II - Correlation and regression

    NASA Technical Reports Server (NTRS)

    Isobe, T.; Feigelson, E. D.; Nelson, P. I.

    1986-01-01

    Statistical methods for calculating correlations and regressions in bivariate censored data where the dependent variable can have upper or lower limits are presented. Cox's regression and the generalization of Kendall's rank correlation coefficient provide significant levels of correlations, and the EM algorithm, under the assumption of normally distributed errors, and its nonparametric analog using the Kaplan-Meier estimator, give estimates for the slope of a regression line. Monte Carlo simulations demonstrate that survival analysis is reliable in determining correlations between luminosities at different bands. Survival analysis is applied to CO emission in infrared galaxies, X-ray emission in radio galaxies, H-alpha emission in cooling cluster cores, and radio emission in Seyfert galaxies.

  9. Biomechanical factors associated with time to complete a change of direction cutting maneuver.

    PubMed

    Marshall, Brendan M; Franklyn-Miller, Andrew D; King, Enda A; Moran, Kieran A; Strike, Siobhán C; Falvey, Éanna C

    2014-10-01

    Cutting ability is an important aspect of many team sports, however, the biomechanical determinants of cutting performance are not well understood. This study aimed to address this issue by identifying the kinetic and kinematic factors correlated with the time to complete a cutting maneuver. In addition, an analysis of the test-retest reliability of all biomechanical measures was performed. Fifteen (n = 15) elite multidirectional sports players (Gaelic hurling) were recruited, and a 3-dimensional motion capture analysis of a 75° cut was undertaken. The factors associated with cutting time were determined using bivariate Pearson's correlations. Intraclass correlation coefficients (ICCs) were used to examine the test-retest reliability of biomechanical measures. Five biomechanical factors were associated with cutting time (2.28 ± 0.11 seconds): peak ankle power (r = 0.77), peak ankle plantar flexor moment (r = 0.65), range of pelvis lateral tilt (r = -0.54), maximum thorax lateral rotation angle (r = 0.51), and total ground contact time (r = -0.48). Intraclass correlation coefficient scores for these 5 factors, and indeed for the majority of the other biomechanical measures, ranged from good to excellent (ICC >0.60). Explosive force production about the ankle, pelvic control during single-limb support, and torso rotation toward the desired direction of travel were all key factors associated with cutting time. These findings should assist in the development of more effective training programs aimed at improving similar cutting performances. In addition, test-retest reliability scores were generally strong, therefore, motion capture techniques seem well placed to further investigate the determinants of cutting ability.

  10. The number of measurements needed to obtain high reliability for traits related to enzymatic activities and photosynthetic compounds in soybean plants infected with Phakopsora pachyrhizi.

    PubMed

    Oliveira, Tássia Boeno de; Azevedo Peixoto, Leonardo de; Teodoro, Paulo Eduardo; Alvarenga, Amauri Alves de; Bhering, Leonardo Lopes; Campo, Clara Beatriz Hoffmann

    2018-01-01

    Asian rust affects the physiology of soybean plants and causes losses in yield. Repeatability coefficients may help breeders to know how many measurements are needed to obtain a suitable reliability for a target trait. Therefore, the objectives of this study were to determine the repeatability coefficients of 14 traits in soybean plants inoculated with Phakopsora pachyrhizi and to establish the minimum number of measurements needed to predict the breeding value with high accuracy. Experiments were performed in a 3x2 factorial arrangement with three treatments and two inoculations in a random block design. Repeatability coefficients, coefficients of determination and number of measurements needed to obtain a certain reliability were estimated using ANOVA, principal component analysis based on the covariance matrix and the correlation matrix, structural analysis and mixed model. It was observed that the principal component analysis based on the covariance matrix out-performed other methods for almost all traits. Significant differences were observed for all traits except internal CO2 concentration for the treatment effects. For the measurement effects, all traits were significantly different. In addition, significant differences were found for all Treatment x Measurement interaction traits except coumestrol, chitinase and chlorophyll content. Six measurements were suitable to obtain a coefficient of determination higher than 0.7 for all traits based on principal component analysis. The information obtained from this research will help breeders and physiologists determine exactly how many measurements are needed to evaluate each trait in soybean plants infected by P. pachyrhizi with a desirable reliability.

  11. The number of measurements needed to obtain high reliability for traits related to enzymatic activities and photosynthetic compounds in soybean plants infected with Phakopsora pachyrhizi

    PubMed Central

    de Oliveira, Tássia Boeno; Teodoro, Paulo Eduardo; de Alvarenga, Amauri Alves; Bhering, Leonardo Lopes; Campo, Clara Beatriz Hoffmann

    2018-01-01

    Asian rust affects the physiology of soybean plants and causes losses in yield. Repeatability coefficients may help breeders to know how many measurements are needed to obtain a suitable reliability for a target trait. Therefore, the objectives of this study were to determine the repeatability coefficients of 14 traits in soybean plants inoculated with Phakopsora pachyrhizi and to establish the minimum number of measurements needed to predict the breeding value with high accuracy. Experiments were performed in a 3x2 factorial arrangement with three treatments and two inoculations in a random block design. Repeatability coefficients, coefficients of determination and number of measurements needed to obtain a certain reliability were estimated using ANOVA, principal component analysis based on the covariance matrix and the correlation matrix, structural analysis and mixed model. It was observed that the principal component analysis based on the covariance matrix out-performed other methods for almost all traits. Significant differences were observed for all traits except internal CO2 concentration for the treatment effects. For the measurement effects, all traits were significantly different. In addition, significant differences were found for all Treatment x Measurement interaction traits except coumestrol, chitinase and chlorophyll content. Six measurements were suitable to obtain a coefficient of determination higher than 0.7 for all traits based on principal component analysis. The information obtained from this research will help breeders and physiologists determine exactly how many measurements are needed to evaluate each trait in soybean plants infected by P. pachyrhizi with a desirable reliability. PMID:29438380

  12. Dynamics analysis of SIR epidemic model with correlation coefficients and clustering coefficient in networks.

    PubMed

    Zhang, Juping; Yang, Chan; Jin, Zhen; Li, Jia

    2018-07-14

    In this paper, the correlation coefficients between nodes in states are used as dynamic variables, and we construct SIR epidemic dynamic models with correlation coefficients by using the pair approximation method in static networks and dynamic networks, respectively. Considering the clustering coefficient of the network, we analytically investigate the existence and the local asymptotic stability of each equilibrium of these models and derive threshold values for the prevalence of diseases. Additionally, we obtain two equivalent epidemic thresholds in dynamic networks, which are compared with the results of the mean field equations. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. A novel coefficient for detecting and quantifying asymmetry of California electricity market based on asymmetric detrended cross-correlation analysis

    NASA Astrophysics Data System (ADS)

    Wang, Fang

    2016-06-01

    In order to detect and quantify asymmetry of two time series, a novel cross-correlation coefficient is proposed based on recent asymmetric detrended cross-correlation analysis (A-DXA), which we called A-DXA coefficient. The A-DXA coefficient, as an important extension of DXA coefficient ρ D X A , contains two directional asymmetric cross-correlated indexes, describing upwards and downwards asymmetric cross-correlations, respectively. By using the information of directional covariance function of two time series and directional variance function of each series itself instead of power-law between the covariance function and time scale, the proposed A-DXA coefficient can well detect asymmetry between the two series no matter whether the cross-correlation is significant or not. By means of the proposed A-DXA coefficient conducted over the asymmetry for California electricity market, we found that the asymmetry between the prices and loads is not significant for daily average data in 1999 yr market (before electricity crisis) but extremely significant for those in 2000 yr market (during the crisis). To further uncover the difference of asymmetry between the years 1999 and 2000, a modified H statistic (MH) and ΔMH statistic are proposed. One of the present contributions is that the high MH values calculated for hourly data exist in majority months in 2000 market. Another important conclusion is that the cross-correlation with downwards dominates over the whole 1999 yr in contrast to the cross-correlation with upwards dominates over the 2000 yr.

  14. Correlation Between Fractional Anisotropy and Motor Outcomes in One-Year-Old Infants with Periventricular Brain Injury

    PubMed Central

    Madhavan, Sangeetha; Campbell, Suzann K.; Campise-Luther, Rose; Gaebler-Spira, Deborah; Zawacki, Laura; Clark, April; Boynewicz, Kara; Kale, Dipti; Bulanda, Michelle; Yu, Jinsheng; Sui, Yi; Zhou, Xiaohong Joe

    2014-01-01

    Purpose To determine whether motor outcomes of an exercise intervention beginning at 2 months corrected age (CA) in children with periventricular brain injury (PBI) are correlated with fractional anisotropy (FA) measures derived from diffusion tensor imaging (DTI) at 12 months CA. Materials and Methods DTI was performed in eight infants with PBI who were randomly assigned to kicking and treadmill stepping exercise or a no-training condition. Development was assessed using the Alberta Infant Motor Scale (AIMS) and the Gross Motor Function Classification System (GMFCS). FA values were derived from regions of interest (ROI) in the middle third of the posterior limb of the internal capsule (PLIC) and the posterior thalamic radiation (PTR). Results Significant correlations were observed between motor development and FA measures. For PLIC, the correlation coefficients were 0.82 between FA and AIMS, and -0.92 between FA and GMFCS, while for PTR the corresponding correlation coefficients were 0.73 and -0.80, respectively. Conclusion Results of this study suggest that quantitative evaluation of white matter tracts using DTI at 12 months CA may be useful for assessment of brain plasticity in children. PMID:24136687

  15. Correlation between fractional anisotropy and motor outcomes in one-year-old infants with periventricular brain injury.

    PubMed

    Madhavan, Sangeetha; Campbell, Suzann K; Campise-Luther, Rose; Gaebler-Spira, Deborah; Zawacki, Laura; Clark, April; Boynewicz, Kara; Kale, Dipti; Bulanda, Michelle; Yu, Jinsheng; Sui, Yi; Zhou, Xiaohong Joe

    2014-04-01

    To determine whether motor outcomes of an exercise intervention beginning at 2 months corrected age (CA) in children with periventricular brain injury (PBI) are correlated with fractional anisotropy (FA) measures derived from diffusion tensor imaging (DTI) at 12 months CA. DTI was performed in eight infants with PBI who were randomly assigned to kicking and treadmill stepping exercise or a no-training condition. Development was assessed using the Alberta Infant Motor Scale (AIMS) and the Gross Motor Function Classification System (GMFCS). FA values were derived from regions of interest (ROIs) in the middle third of the posterior limb of the internal capsule (PLIC) and the posterior thalamic radiation (PTR). Significant correlations were observed between motor development and FA measures. For PLIC, the correlation coefficients were 0.82 between FA and AIMS, and -0.92 between FA and GMFCS, while for PTR the corresponding correlation coefficients were 0.73 and -0.80, respectively. Results of this study suggest that quantitative evaluation of white matter tracts using DTI at 12 months CA may be useful for assessment of brain plasticity in children. Copyright © 2013 Wiley Periodicals, Inc.

  16. Extracting near-surface QL between 1-4 Hz from higher-order noise correlations in the Euroseistest area, Greece

    NASA Astrophysics Data System (ADS)

    Haendel, A.; Ohrnberger, M.; Krüger, F.

    2016-11-01

    Knowledge of the quality factor of near-surface materials is of fundamental interest in various applications. Attenuation can be very strong close to the surface and thus needs to be properly assessed. In recent years, several researchers have studied the retrieval of attenuation coefficients from the cross correlation of ambient seismic noise. Yet, the determination of exact amplitude information from noise-correlation functions is, in contrast to the extraction of traveltimes, not trivial. Most of the studies estimated attenuation coefficients on the regional scale and within the microseism band. In this paper, we investigate the possibility to derive attenuation coefficients from seismic noise at much shallower depths and higher frequencies (>1 Hz). The Euroseistest area in northern Greece offers ideal conditions to study quality factor retrieval from ambient noise for different rock types. Correlations are computed between the stations of a small scale array experiment (station spacings <2 km) that was carried out in the Euroseistest area in 2011. We employ the correlation of the coda of the correlation (C3) method instead of simple cross correlations to mitigate the effect of uneven noise source distributions on the correlation amplitude. Transient removal and temporal flattening are applied instead of 1-bit normalization in order to retain relative amplitudes. The C3 method leads to improved correlation results (higher signal-to-noise ratio and improved time symmetry) compared to simple cross correlations. The C3 functions are rotated from the ZNE to the ZRT system and we focus on Love wave arrivals on the transverse component and on Love wave quality factors QL. The analysis is performed for selected stations being either situated on soft soil or on weathered rock. Phase slowness is extracted using a slant-stack method. Attenuation parameters are inferred by inspecting the relative amplitude decay of Love waves with increasing interstation distance. We observe that the attenuation coefficient γ and QL can be reliably extracted for stations situated on soft soil whereas the derivation of attenuation parameters is more problematic for stations that are located on weathered rock. The results are in acceptable conformance with theoretical Love wave attenuation curves that were computed using 1-D shear wave velocity and quality factor profiles from the Euroseistest area.

  17. Evaluation of the Correlation Coefficient of Polyethylene Glycol Treated and Direct Prolactin Results and Comparability with Different Assay System Results.

    PubMed

    Pal, Shyamali

    2017-12-01

    The presence of Macro prolactin is a significant cause of elevated prolactin resulting in misdiagnosis in all automated systems. Poly ethylene glycol (PEG) pretreatment is the preventive process but such process includes the probability of loss of a fraction of bioactive prolactin. Surprisingly, PEG treated EQAS & IQAS samples in Cobas e 411 are found out to be correlating with direct results of at least 3 immunoassay systems and treated and untreated Cobas e 411 results are comparable by a correlation coefficient. Comparison of EQAS, IQAS and patient samples were done to find out the trueness of such correlation factor. Study with patient's results have established the correlation coefficient is valid for very small concentration of prolactin also. EQAS, IQAS and 150 patient samples were treated with PEG and prolactin results of treated and untreated samples obtained from Roche Cobas e 411. 25 patient's results (treated) were compared with direct results in Advia Centaur, Architect I & Access2 systems. Correlation coefficient was obtained from trend line of the treated and untreated results. Two tailed p-value obtained from regression coefficient(r) and sample size. The correlation coefficient is in the range (0.761-0.771). Reverse correlation range is (1.289-1.301). r value of two sets of calculated results were 0.995. Two tailed p- value is zero approving dismissal of null hypothesis. The z-score of EQAS does not always assure authenticity of resultsPEG precipitation is correlated by the factor 0.761 even in very small concentrationsAbbreviationsGFCgel filtration chromatographyPEGpolyethylene glycolEQASexternal quality assurance systemM-PRLmacro prolactinPRLprolactinECLIAelectro-chemiluminescence immunoassayCLIAclinical laboratory improvement amendmentsIQASinternal quality assurance systemrregression coefficient.

  18. Central Corneal Thickness Reproducibility among Ten Different Instruments.

    PubMed

    Pierro, Luisa; Iuliano, Lorenzo; Gagliardi, Marco; Ambrosi, Alessandro; Rama, Paolo; Bandello, Francesco

    2016-11-01

    To assess agreement between one ultrasonic (US) and nine optical instruments for the measurement of central corneal thickness (CCT), and to evaluate intra- and inter-operator reproducibility. In this observational cross-sectional study, two masked operators measured CCT thickness twice in 28 healthy eyes. We used seven spectral-domain optical coherence tomography (SD-OCT) devices, one time-domain OCT, one Scheimpflug camera, and one US-based instrument. Inter- and intra-operator reproducibility was evaluated by intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measurements. We also tested how the devices disagreed regarding systemic bias and random error using a structural equation model. Mean CCT of all instruments ranged from 536 ± 42 μm to 577 ± 40 μm. An instrument-to-instrument correlation test showed high values among the 10 investigated devices (correlation coefficient range 0.852-0.995; p values <0.0001 in all cases). The highest correlation coefficient values were registered between 3D OCT-2000 Topcon-Spectral OCT/SLO Opko (0.995) and Cirrus HD-OCT Zeiss-RS-3000 Nidek (0.995), whereas the lowest were seen between SS-1000 CASIA and Spectral OCT/SLO Opko (0.852). ICC and CV showed excellent inter- and intra-operator reproducibility for all optic-based devices, except for the US-based device. Bland-Altman analysis demonstrated low mean biases between operators. Despite highlighting good intra- and inter-operator reproducibility, we found that a scale bias between instruments might interfere with thorough CCT monitoring. We suggest that optimal monitoring is achieved with the same operator and the same device.

  19. Dietary intakes assessed by 24-h recalls in peri-urban African adolescents: validity of energy intake compared with estimated energy expenditure.

    PubMed

    Rankin, D; Ellis, S M; Macintyre, U E; Hanekom, S M; Wright, H H

    2011-08-01

    The objective of this study is to determine the relative validity of reported energy intake (EI) derived from multiple 24-h recalls against estimated energy expenditure (EE(est)). Basal metabolic rate (BMR) equations and physical activity factors were incorporated to calculate EE(est). This analysis was nested in the multidisciplinary PhysicaL Activity in the Young study with a prospective study design. Peri-urban black South African adolescents were investigated in a subsample of 131 learners (87 girls and 44 boys) from the parent study sample of 369 (211 girls and 158 boys) who had all measurements taken. Pearson correlation coefficients and Bland-Altman plots were calculated to identify the most accurate published equations to estimate BMR (P<0.05 statistically significant). EE(est) was estimated using BMR equations and estimated physical activity factors derived from Previous Day Physical Activity Recall questionnaires. After calculation of EE(est), the relative validity of reported energy intake (EI(rep)) derived from multiple 24-h recalls was tested for three data subsets using Pearson correlation coefficients. Goldberg's formula identified cut points (CPs) for under and over reporting of EI. Pearson correlation coefficients between calculated BMRs ranged from 0.97 to 0.99. Bland-Altman analyses showed acceptable agreement (two equations for each gender). One equation for each gender was used to calculate EE(est). Pearson correlation coefficients between EI(rep) and EE(est) for three data sets were weak, indicating poor agreement. CPs for physical activity groups showed under reporting in 87% boys and 95% girls. The 24-h recalls measured at five measurements over 2 years offered poor validity between EI(rep) and EE(est).

  20. Simplified Radiographic Damage Index for Affected Joints in Chronic Gouty Arthritis

    PubMed Central

    2016-01-01

    The aim of this study was to develop and validate a new radiographic damage scoring method (DAmagE index of GoUt; DAEGU) in chronic gout using plain radiography. Two independent observers scored foot x-rays from 15 patients with chronic gout according to the DAEGU method and the modified Sharp/van der Heijde (SvdH) method. The 10 metatarsophalangeal (MTP) and 2 interphalangeal (IP) joints of the first toes of both feet were scored to assess the degrees of erosion and joint space narrowing (JSN). The intraobserver and interobserver reliabilities were analyzed by calculating the intraclass correlation coefficient (ICC) and minimal detectable change (MDC). The correlation between the DAEGU and SvdH methods was analyzed by calculating the Spearman's rho correlation coefficients and Kappa coefficients. The DAEGU method was found to be highly reproducible (0.945–0.987 for the intraobserver and 0.993–0.996 for the interobserver ICC values). The erosion, JSN, and total scores exhibited strong positive correlations between the DAEGU and SvdH methods and also within each method (r = 0.860–0.969, P < 0.001 for all parameters). The DAEGU and SvdH methods were in very good agreement as determined by Kappa coefficient analysis [0.732 (0.387–1.000) for erosion and 1.000 (1.000–1.000) for JSN]. In conclusion, this study revealed that DAEGU method was a reliable and feasible tool in the assessment of radiographic damage in chronic gout. The DAEGU method may provide a more easy assessment of structural damage in chronic gout in the real clinical practice. PMID:26955246

  1. Reliability and concurrent validity of the adapted Chinese version of Scoliosis Research Society-22 (SRS-22) questionnaire.

    PubMed

    Cheung, Kenneth M C; Senkoylu, Alpaslan; Alanay, Ahmet; Genc, Yasemin; Lau, Sarah; Luk, Keith D

    2007-05-01

    Validation study to define validity and reliability of an adapted and translated questionnaire. Assessment of the concurrent validity and reliability of a Chinese version of SRS-22 outcome instrument. No valid health-related quality of life (HRQL) outcome instrument exists for patients with spinal deformity in Chinese. The modified SRS-22 questionnaire was proven to be an appropriate outcome instrument in English, and has already been translated and validated in several other languages. The English version of the SRS-22 questionnaire was adapted to Chinese according to the International Quality of Life Assessment Project guidelines. To assess reliability, 48 subjects with adolescent idiopathic scoliosis (mean age, 16.5 years) filled the questionnaire on 2 separate occasions (Group 1). To assess concurrent validity, 50 subjects (mean age, 21 years) filled in the same questionnaire and a previously validated Chinese version of the Short Form-36 (SF36) questionnaire (Group 2). Internal consistency, reproducibility and concurrent validity were determined with Cronbach's alpha coefficient, interclass correlation coefficient and Pearson correlation coefficient, respectively. Cronbach's alpha coefficient for the 4 major domains (function/activity, pain, self-image/appearance and mental health) were high. Intraclass correlation was also excellent for all domains. For concurrent validity, excellent correlation was found in 1 domain, good in 12 domains, moderate in 3 domains, and poor in 1 domain of the 17 relevant domains. Both cultural adaptation and linguistic translation are essential in any attempt to use a HRQL questionnaire across cultures. The Chinese version of the SRS-22 outcome instrument has satisfactory internal consistency and excellent reproducibility. It is ready for use in clinical studies on idiopathic scoliosis in Chinese-speaking societies.

  2. Statistical analysis and digital processing of the Mössbauer spectra

    NASA Astrophysics Data System (ADS)

    Prochazka, Roman; Tucek, Pavel; Tucek, Jiri; Marek, Jaroslav; Mashlan, Miroslav; Pechousek, Jiri

    2010-02-01

    This work is focused on using the statistical methods and development of the filtration procedures for signal processing in Mössbauer spectroscopy. Statistical tools for noise filtering in the measured spectra are used in many scientific areas. The use of a pure statistical approach in accumulated Mössbauer spectra filtration is described. In Mössbauer spectroscopy, the noise can be considered as a Poisson statistical process with a Gaussian distribution for high numbers of observations. This noise is a superposition of the non-resonant photons counting with electronic noise (from γ-ray detection and discrimination units), and the velocity system quality that can be characterized by the velocity nonlinearities. The possibility of a noise-reducing process using a new design of statistical filter procedure is described. This mathematical procedure improves the signal-to-noise ratio and thus makes it easier to determine the hyperfine parameters of the given Mössbauer spectra. The filter procedure is based on a periodogram method that makes it possible to assign the statistically important components in the spectral domain. The significance level for these components is then feedback-controlled using the correlation coefficient test results. The estimation of the theoretical correlation coefficient level which corresponds to the spectrum resolution is performed. Correlation coefficient test is based on comparison of the theoretical and the experimental correlation coefficients given by the Spearman method. The correctness of this solution was analyzed by a series of statistical tests and confirmed by many spectra measured with increasing statistical quality for a given sample (absorber). The effect of this filter procedure depends on the signal-to-noise ratio and the applicability of this method has binding conditions.

  3. A novel measure and significance testing in data analysis of cell image segmentation.

    PubMed

    Wu, Jin Chu; Halter, Michael; Kacker, Raghu N; Elliott, John T; Plant, Anne L

    2017-03-14

    Cell image segmentation (CIS) is an essential part of quantitative imaging of biological cells. Designing a performance measure and conducting significance testing are critical for evaluating and comparing the CIS algorithms for image-based cell assays in cytometry. Many measures and methods have been proposed and implemented to evaluate segmentation methods. However, computing the standard errors (SE) of the measures and their correlation coefficient is not described, and thus the statistical significance of performance differences between CIS algorithms cannot be assessed. We propose the total error rate (TER), a novel performance measure for segmenting all cells in the supervised evaluation. The TER statistically aggregates all misclassification error rates (MER) by taking cell sizes as weights. The MERs are for segmenting each single cell in the population. The TER is fully supported by the pairwise comparisons of MERs using 106 manually segmented ground-truth cells with different sizes and seven CIS algorithms taken from ImageJ. Further, the SE and 95% confidence interval (CI) of TER are computed based on the SE of MER that is calculated using the bootstrap method. An algorithm for computing the correlation coefficient of TERs between two CIS algorithms is also provided. Hence, the 95% CI error bars can be used to classify CIS algorithms. The SEs of TERs and their correlation coefficient can be employed to conduct the hypothesis testing, while the CIs overlap, to determine the statistical significance of the performance differences between CIS algorithms. A novel measure TER of CIS is proposed. The TER's SEs and correlation coefficient are computed. Thereafter, CIS algorithms can be evaluated and compared statistically by conducting the significance testing.

  4. Thermodiffusion, molecular diffusion and Soret coefficient of binary and ternary mixtures of n-hexane, n-dodecane and toluene.

    PubMed

    Alonso de Mezquia, David; Wang, Zilin; Lapeira, Estela; Klein, Michael; Wiegand, Simone; Mounir Bou-Ali, M

    2014-11-01

    In this study, the thermodiffusion, molecular diffusion, and Soret coefficients of 12 binary mixtures composed of toluene, n-hexane and n-dodecane in the whole range of concentrations at atmospheric pressure and temperatures of 298.15 K and 308.15 K have been determined. The experimental measurements have been carried out using the Thermogravitational Column, the Sliding Symmetric Tubes and the Thermal Diffusion Forced Rayleigh Scattering techniques. The results obtained using the different techniques show a maximum deviation of 9% for the thermodiffusion coefficient, 8% for the molecular diffusion coefficient and 2% for the Soret coefficient. For the first time we report a decrease of the thermodiffusion coefficient with increasing ratio of the thermal expansion coefficient and viscosity for a binary mixture of an organic ring compound with a short n-alkane. This observation is discussed in terms of interactions between the different components. Additionally, the thermogravitational technique has been used to measure the thermodiffusion coefficients of four ternary mixtures consisting of toluene, n-hexane and n-dodecane at 298.15 K. In order to complete the study, the values obtained for the molecular diffusion coefficient in binary mixtures, and the thermodiffusion coefficient of binary and ternary mixtures have been compared with recently derived correlations.

  5. Newly found evidence of Sun-climate relationships

    NASA Technical Reports Server (NTRS)

    Kim, Hongsuk H.; Huang, Norden E.

    1993-01-01

    Solar radiation cycles drive climatic changes intercyclically. These interdecadal changes were detected as variations in solar total irradiances over the time period of recorded global surface-air-temperature (SAT) and have been restored utilizing Earth Radiation Budget Channel 10C measurements (1978-1990), Greenwich Observatory faculae data (1874-1975), and Taipei Observatory Active Region data (1964-1991). Analysis of the two separate events was carried out by treating each as a discrete time series determined by the length of each solar cycle. The results show that the global SAT responded closely to the input of solar cyclical activities, S, with a quantitative relation of T = 1.62 * S with a correlation coefficient of 0.61. This correlation peaks at 0.71 with a built-in time lag of 32 months in temperature response. Solar forcing in interannual time scale was also detected and the derived relationship of T = 0.17 * S with a correlation coefficient of 0.66 was observed. Our analysis shows derived climate sensitivities approximately fit the theoretical feedback slope, 4T(sup 3).

  6. The Edematous and Erythematous Airway Does Not Denote Pathologic Gastroesophageal Reflux.

    PubMed

    Rosen, Rachel; Mitchell, Paul D; Amirault, Janine; Amin, Manali; Watters, Karen; Rahbar, Reza

    2017-04-01

    To determine if the reflux finding score (RFS), a validated score for airway inflammation, correlates with gastroesophageal reflux measured by multichannel intraluminal impedance (MII) testing, endoscopy, and quality of life scores. We performed a prospective, cross-sectional cohort study of 77 children with chronic cough undergoing direct laryngoscopy and bronchoscopy, esophagogastroduodenoscopy, and MII testing with pH (pH-MII) between 2006 and 2011. Airway examinations were videotaped and reviewed by 3 blinded otolaryngologists each of whom assigned RFS to the airways. RFS were compared with the results of reflux testing (endoscopy, MII, symptom scores). An intraclass correlation coefficient was calculated for the degree of agreement between otolaryngologists' RFS. Receiver operating characteristic curves were created to determine the sensitivity of the RFS. Spearman correlation was calculated between the RFS and reflux measurements by pH-MII. The mean ± SD RFS was 12 ± 4. There was no correlation between pH-MII variables and mean RFS (|r| < 0.15). The concordance correlation coefficient for RFS between otolaryngologists was low (intraclass correlation coefficient = 0.32). Using pH-metry as a gold standard, the positive predictive value for the RFS was 29%. Using MII as the gold standard, the positive predictive value for the RFS was 40%. There was no difference in the mean RFS in patients with (12 ± 4) and without (12 ± 3) esophagitis (P = .9). There was no correlation between RFS and quality of life scores (|r| < 0.15, P > .3). The RFS cannot predict pathologic gastroesophageal reflux and an airway examination should not be used as a basis for prescribing gastroesophageal reflux therapies. Copyright © 2016. Published by Elsevier Inc.

  7. Determination of organic compounds in water using ultraviolet LED

    NASA Astrophysics Data System (ADS)

    Kim, Chihoon; Ji, Taeksoo; Eom, Joo Beom

    2018-04-01

    This paper describes a method of detecting organic compounds in water using an ultraviolet LED (280 nm) spectroscopy system and a photodetector. The LED spectroscopy system showed a high correlation between the concentration of the prepared potassium hydrogen phthalate and that calculated by multiple linear regression, indicating an adjusted coefficient of determination ranging from 0.953-0.993. In addition, a comparison between the performance of the spectroscopy system and the total organic carbon analyzer indicated that the difference in concentration was small. Based on the close correlation between the spectroscopy and photodetector absorbance values, organic measurement with a photodetector could be configured for monitoring.

  8. Performance of chromatographic systems to model soil-water sorption.

    PubMed

    Hidalgo-Rodríguez, Marta; Fuguet, Elisabet; Ràfols, Clara; Rosés, Martí

    2012-08-24

    A systematic approach for evaluating the goodness of chromatographic systems to model the sorption of neutral organic compounds by soil from water is presented in this work. It is based on the examination of the three sources of error that determine the overall variance obtained when soil-water partition coefficients are correlated against chromatographic retention factors: the variance of the soil-water sorption data, the variance of the chromatographic data, and the variance attributed to the dissimilarity between the two systems. These contributions of variance are easily predicted through the characterization of the systems by the solvation parameter model. According to this method, several chromatographic systems besides the reference octanol-water partition system have been selected to test their performance in the emulation of soil-water sorption. The results from the experimental correlations agree with the predicted variances. The high-performance liquid chromatography system based on an immobilized artificial membrane and the micellar electrokinetic chromatography systems of sodium dodecylsulfate and sodium taurocholate provide the most precise correlation models. They have shown to predict well soil-water sorption coefficients of several tested herbicides. Octanol-water partitions and high-performance liquid chromatography measurements using C18 columns are less suited for the estimation of soil-water partition coefficients. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. The reliability of Cavalier's principle of stereological method in determining volumes of enchondromas using the computerized tomography tools.

    PubMed

    Acar, Nihat; Karakasli, Ahmet; Karaarslan, Ahmet; Mas, Nermin Ng; Hapa, Onur

    2017-01-01

    Volumetric measurements of benign tumors enable surgeons to trace volume changes during follow-up periods. For a volumetric measurement technique to be applicable, it should be easy, rapid, and inexpensive and should carry a high interobserver reliability. We aimed to assess the interobserver reliability of a volumetric measurement technique using the Cavalier's principle of stereological methods. The computerized tomography (CT) of 15 patients with a histopathologically confirmed diagnosis of enchondroma with variant tumor sizes and localizations was retrospectively reviewed for interobserver reliability evaluation of the volumetric stereological measurement with the Cavalier's principle, V = t × [((SU) × d) /SL]2 × Σ P. The volumes of the 15 tumors collected by the observers are demonstrated in Table 1. There was no statistical significance between the first and second observers ( p = 0.000 and intraclass correlation coefficient = 0.970) and between the first and third observers ( p = 0.000 and intraclass correlation coefficient = 0.981). No statistical significance was detected between the second and third observers ( p = 0.000 and intraclass correlation coefficient = 0.976). The Cavalier's principle with the stereological technique using the CT scans is an easy, rapid, and inexpensive technique in volumetric evaluation of enchondromas with a trustable interobserver reliability.

  10. Calculating sediment discharge from a highway construction site in central Pennsylvania

    USGS Publications Warehouse

    Reed, L.A.; Ward, J.R.; Wetzel, K.L.

    1985-01-01

    The Pennsylvania Department of Transportation, the Federal Highway Administration, and the U.S. Geological Survey have cooperated in a study to evaluate two methods of predicting sediment yields during highway construction. Sediment yields were calculated using the Universal Soil Loss and the Younkin Sediment Prediction Equations. Results were compared to the actual measured values, and standard errors and coefficients of correlation were calculated. Sediment discharge from the construction area was determined for storms that occurred during construction of Interstate 81 in a 0.38-square mile basin near Harrisburg, Pennsylvania. Precipitation data tabulated included total rainfall, maximum 30-minute rainfall, kinetic energy, and the erosive index of the precipitation. Highway construction data tabulated included the area disturbed by clearing and grubbing, the area in cuts and fills, the average depths of cuts and fills, the area seeded and mulched, and the area paved. Using the Universal Soil Loss Equation, sediment discharge from the construction area was calculated for storms. The standard error of estimate was 0.40 (about 105 percent), and the coefficient of correlation was 0.79. Sediment discharge from the construction area was also calculated using the Younkin Equation. The standard error of estimate of 0.42 (about 110 percent), and the coefficient of correlation of 0.77 are comparable to those from the Universal Soil Loss Equation.

  11. Anthropometry of Women of the U.S. Army--1977. Report Number 4. Correlation Coefficients

    DTIC Science & Technology

    1980-02-01

    S.... •, 0 76 x:. ADo5 //64 ! TECHNICAL REPORT NATICK/TR-80/016 (/ II ANTHROPOMETRY OF WOMEN OF THE U.S. ARMY-1977 Report No. 4 Correlation...NUMBER NATICK/TR-80/016 4. TITLE (and Subtitle) 5. TYPE OF REPORT & PERIOD COVERED ANTHROPOMETRY OF WOMEN OF THE U.S. ARMY--1977 Technical Report REPORT NO... Anthropometry Survey(s) Coefficients of correlation Measurement(s) U.S. Army Correlation coefficients Body size Military personnel Equation(s) Sizes

  12. Fast determination of total ginsenosides content in ginseng powder by near infrared reflectance spectroscopy

    NASA Astrophysics Data System (ADS)

    Chen, Hua-cai; Chen, Xing-dan; Lu, Yong-jun; Cao, Zhi-qiang

    2006-01-01

    Near infrared (NIR) reflectance spectroscopy was used to develop a fast determination method for total ginsenosides in Ginseng (Panax Ginseng) powder. The spectra were analyzed with multiplicative signal correction (MSC) correlation method. The best correlative spectra region with the total ginsenosides content was 1660 nm~1880 nm and 2230nm~2380 nm. The NIR calibration models of ginsenosides were built with multiple linear regression (MLR), principle component regression (PCR) and partial least squares (PLS) regression respectively. The results showed that the calibration model built with PLS combined with MSC and the optimal spectrum region was the best one. The correlation coefficient and the root mean square error of correction validation (RMSEC) of the best calibration model were 0.98 and 0.15% respectively. The optimal spectrum region for calibration was 1204nm~2014nm. The result suggested that using NIR to rapidly determinate the total ginsenosides content in ginseng powder were feasible.

  13. DCCA cross-correlation coefficients reveals the change of both synchronization and oscillation in EEG of Alzheimer disease patients

    NASA Astrophysics Data System (ADS)

    Chen, Yingyuan; Cai, Lihui; Wang, Ruofan; Song, Zhenxi; Deng, Bin; Wang, Jiang; Yu, Haitao

    2018-01-01

    Alzheimer's disease (AD) is a degenerative disorder of neural system that affects mainly the older population. Recently, many researches show that the EEG of AD patients can be characterized by EEG slowing, enhanced complexity of the EEG signals, and EEG synchrony. In order to examine the neural synchrony at multi scales, and to find a biomarker that help detecting AD in diagnosis, detrended cross-correlation analysis (DCCA) of EEG signals is applied in this paper. Several parameters, namely DCCA coefficients in the whole brain, DCCA coefficients at a specific scale, maximum DCCA coefficient over the span of all time scales and the corresponding scale of such coefficients, were extracted to examine the synchronization, respectively. The results show that DCCA coefficients have a trend of increase as scale increases, and decreases as electrode distance increases. Comparing DCCA coefficients in AD patients with healthy controls, a decrease of synchronization in the whole brain, and a bigger scale corresponding to maximum correlation is discovered in AD patients. The change of max-correlation scale may relate to the slowing of oscillatory activities. Linear combination of max DCCA coefficient and max-correlation scale reaches a classification accuracy of 90%. From the above results, it is reasonable to conclude that DCCA coefficient reveals the change of both oscillation and synchrony in AD, and thus is a powerful tool to differentiate AD patients from healthy elderly individuals.

  14. Validity of EuroQOL-5D, time trade-off, and standard gamble for age-related macular degeneration in the Singapore population

    PubMed Central

    Au Eong, K G; Chan, E W; Luo, N; Wong, S H; Tan, N W H; Lim, T H; Wagle, A M

    2012-01-01

    Background/aims Utility values of age-related macular degeneration (AMD) in Asian patients are unknown. This study aims to assess utility values and construct validity of the EuroQOL-5D (EQ-5D), time trade-off (TTO), and standard gamble (SG) instruments in the Singapore multi-ethnic AMD population. Methods Cross-sectional, two-centre, institution-based study. Visual acuity (VA), clinical AMD severity, and utility scores on the EQ-5D, TTO, and SG were obtained from 338 AMD patients. VA was analysed in terms of the better-seeing eye (BEVA), worse-seeing eye (WEVA), and weighted average of both eyes (WVA). We evaluated SG on the perfect health-death (SG(death)) and binocular perfect vision-binocular blindness (SG(blindness)) scales. Construct validity was determined by testing a priorihypotheses relating the EQ-5D, TTO, and SG utility scores to VA and clinical AMD severity. Results The mean utilities on the EQ-5D, TTO, SG(death), and SG(blindness) were 0.89, 0.81, 0.86, and 0.90, respectively. EQ-5D scores correlated weakly with BEVA, WEVA, and WVA (Pearson's correlation coefficients −0.291, −0.247, and −0.305 respectively, P<0.001 for all). SG(death) and SG(blindness) demonstrated no correlation with BEVA, WEVA, or WVA (Pearson's correlation coefficients, range −0.06 to −0.125). TTO showed weak association only with WEVA and WVA (correlation coefficients −0.237, −0.228, P<0.0001), but not with BEVA (correlation coefficient −0.161). Clinical AMD severity correlated with EQ-5D and SG(death), but not with TTO and SG(blindness) (P=0.004, 0.002, 0.235, and 0.069, respectively). Conclusions AMD has a negative impact on utilities, although utility scores were high compared with Western cohorts. EQ-5D, TTO, and SG showed suboptimal construct validity, suggesting that health status utilities may not be sufficiently robust for cost-utility analyses in this population. PMID:22222257

  15. [Quantitative determination of glass content in monazite glass-ceramics by IR technique].

    PubMed

    He, Yong; Zhang, Bao-min

    2003-04-01

    Monazite glass-ceramics consist of both monazite and metaphoshate glass phases. The absorption bands of both phases do not overlap each other, and the absorption intensities of bands 1,275 and 616 cm-1 vary with the glass contents. The correlation coefficient between logarithmic absorbance ratio of the two bands and glass contents was r = 0.9975 and its regression equation was y = 48.356 + 25.93x. The absorbance ratio of bands 952 and 616 cm-1 also varied with different ratios of Ce2O3/La2O3 in synthetic monazites, with r = 0.9917 and a regression equation y = 0.2211 exp (0.0221x). High correlation coefficients show that the IR technique could find new application in the quantitative analysis of glass content in phosphate glass-ceramics.

  16. Statistics corner: A guide to appropriate use of correlation coefficient in medical research.

    PubMed

    Mukaka, M M

    2012-09-01

    Correlation is a statistical method used to assess a possible linear association between two continuous variables. It is simple both to calculate and to interpret. However, misuse of correlation is so common among researchers that some statisticians have wished that the method had never been devised at all. The aim of this article is to provide a guide to appropriate use of correlation in medical research and to highlight some misuse. Examples of the applications of the correlation coefficient have been provided using data from statistical simulations as well as real data. Rule of thumb for interpreting size of a correlation coefficient has been provided.

  17. [Correlation of molecular weight and nanofiltration mass transfer coefficient of phenolic acid composition from Salvia miltiorrhiza].

    PubMed

    Li, Cun-Yu; Wu, Xin; Gu, Jia-Mei; Li, Hong-Yang; Peng, Guo-Ping

    2018-04-01

    Based on the molecular sieving and solution-diffusion effect in nanofiltration separation, the correlation between initial concentration and mass transfer coefficient of three typical phenolic acids from Salvia miltiorrhiza was fitted to analyze the relationship among mass transfer coefficient, molecular weight and concentration. The experiment showed a linear relationship between operation pressure and membrane flux. Meanwhile, the membrane flux was gradually decayed with the increase of solute concentration. On the basis of the molecular sieving and solution-diffusion effect, the mass transfer coefficient and initial concentration of three phenolic acids showed a power function relationship, and the regression coefficients were all greater than 0.9. The mass transfer coefficient and molecular weight of three phenolic acids were negatively correlated with each other, and the order from high to low is protocatechualdehyde >rosmarinic acid> salvianolic acid B. The separation mechanism of nanofiltration for phenolic acids was further clarified through the analysis of the correlation of molecular weight and nanofiltration mass transfer coefficient. The findings provide references for nanofiltration separation, especially for traditional Chinese medicine with phenolic acids. Copyright© by the Chinese Pharmaceutical Association.

  18. Broadening of polymer chromatographic signals: Analysis, quantification and correction through effective diffusion coefficients.

    PubMed

    Suárez, Inmaculada; Coto, Baudilio

    2015-08-14

    Average molecular weights and polydispersity indexes are some of the most important parameters considered in the polymer characterization. Usually, gel permeation chromatography (GPC) and multi angle light scattering (MALS) are used for this determination, but GPC values are overestimated due to the dispersion introduced by the column separation. Several procedures were proposed to correct such effect usually involving more complex calibration processes. In this work, a new method of calculation has been considered including diffusion effects. An equation for the concentration profile due to diffusion effects along the GPC column was considered to be a Fickian function and polystyrene narrow standards were used to determine effective diffusion coefficients. The molecular weight distribution function of mono and poly disperse polymers was interpreted as a sum of several Fickian functions representing a sample formed by only few kind of polymer chains with specific molecular weight and diffusion coefficient. Proposed model accurately fit the concentration profile along the whole elution time range as checked by the computed standard deviation. Molecular weights obtained by this new method are similar to those obtained by MALS or traditional GPC while polydispersity index values are intermediate between those obtained by the traditional GPC combined to Universal Calibration method and the MALS method. Values for Pearson and Lin coefficients shows improvement in the correlation of polydispersity index values determined by GPC and MALS methods when diffusion coefficients and new methods are used. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chan, G.Y.; Chui, V.W.; Wong, M.H.

    Samples of roadside dust were collected from 30 sites in Hong Kong. The total concentrations of 10 metals in the samples were analyzed, and the correlation coefficients among the metal contents and the annual average daily traffic (AADT) in 1986 were determined. Pb was found to have a significant correlation (P less than 0.01) with AADT. No correlation was found between Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, and Zn with respect to AADT. A general decrease in the level of Pb in roadside dust in the past few years has been observed since the reduction in the levelmore » of lead in petrol.« less

  20. Measurements of experimental precision for trials with cowpea (Vigna unguiculata L. Walp.) genotypes.

    PubMed

    Teodoro, P E; Torres, F E; Santos, A D; Corrêa, A M; Nascimento, M; Barroso, L M A; Ceccon, G

    2016-05-09

    The aim of this study was to evaluate the suitability of statistics as experimental precision degree measures for trials with cowpea (Vigna unguiculata L. Walp.) genotypes. Cowpea genotype yields were evaluated in 29 trials conducted in Brazil between 2005 and 2012. The genotypes were evaluated with a randomized block design with four replications. Ten statistics that were estimated for each trial were compared using descriptive statistics, Pearson correlations, and path analysis. According to the class limits established, selective accuracy and F-test values for genotype, heritability, and the coefficient of determination adequately estimated the degree of experimental precision. Using these statistics, 86.21% of the trials had adequate experimental precision. Selective accuracy and the F-test values for genotype, heritability, and the coefficient of determination were directly related to each other, and were more suitable than the coefficient of variation and the least significant difference (by the Tukey test) to evaluate experimental precision in trials with cowpea genotypes.

  1. Assessing the test-retest repeatability of the Vietnamese version of the National Eye Institute 25-item Visual Function Questionnaire among bilateral cataract patients for a Vietnamese population.

    PubMed

    To, Kien Gia; Meuleners, Lynn; Chen, Huei-Yang; Lee, Andy; Do, Dung Van; Duong, Dat Van; Phi, Tien Duy; Tran, Hoang Huy; Nguyen, Nguyen Do

    2014-06-01

    To determine the test-retest repeatability of the National Eye Institute 25-item Visual Function Questionnaire (NEI VFQ-25) for use with older Vietnamese adults with bilateral cataract. The questionnaire was translated into Vietnamese and back-translated into English by two independent translators. Patients with bilateral cataract aged 50 and older completed the questionnaire on two separate occasions, one to two weeks after first administration of the questionnaire. Test-retest repeatability was assessed using the Cronbach's α and intraclass correlation coefficients. The average age of participants was 67 ± 8 years and most participants were female (73%). Internal consistency was acceptable with the α coefficient above 0.7 for all subscales and intraclass correlation coefficients were 0.6 or greater in all subscales. The Vietnamese NEI VFQ-25 is reliable for use in studies assessing vision-related quality of life in older adults with bilateral cataract in Vietnam. We propose some modifications to the NEI-VFQ questions to reflect activities of older people in Vietnam. © 2013 ACOTA.

  2. Heat transfer and pressure drop in rectangular channels with crossing fins (a Review)

    NASA Astrophysics Data System (ADS)

    Sokolov, N. P.; Polishchuk, V. G.; Andreev, K. D.; Rassokhin, V. A.; Zabelin, N. A.

    2015-06-01

    Channels with crossing finning find wide use in the cooling paths of high-temperature gas turbine blade systems. At different times, different institutions carried out experimental investigations of heat transfer and pressure drop in channels with coplanar finning of opposite walls for obtaining semiempirical dependences of Nusselt criteria (dimensionless heat-transfer coefficients) and pressure drop coefficients on the operating Reynolds number and relative geometrical parameters (or their complexes). The shape of experimental channels, the conditions of experiments, and the used variables were selected so that they would be most suited for solving particular practical tasks. Therefore, the results obtained in processing the experimental data have large scatter and limited use. This article considers the results from experimental investigations of different authors. In comparing the results, additional calculations were carried out for bringing the mathematical correlations to the form of dependences from the same variables. Generalization of the results is carried out. In the final analysis, universal correlations are obtained for determining the pressure drop coefficients and Nusselt number values for the flow of working medium in channels with coplanar finning.

  3. Snapping Sharks, Maddening Mindreaders, and Interactive Images: Teaching Correlation.

    ERIC Educational Resources Information Center

    Mitchell, Mark L.

    Understanding correlation coefficients is difficult for students. A free computer program that helps introductory psychology students distinguish between positive and negative correlation, and which also teaches them to understand the differences between correlation coefficients of different size is described in this paper. The program is…

  4. Dental and Chronological Ages as Determinants of Peak Growth Period and Its Relationship with Dental Calcification Stages

    PubMed Central

    Litsas, George; Lucchese, Alessandra

    2016-01-01

    Purpose: To investigate the relationship between dental, chronological, and cervical vertebral maturation growth in the peak growth period, as well as to study the association between the dental calcification phases and the skeletal maturity stages during the same growth period. Methods: Subjects were selected from orthodontic pre-treatment cohorts consisting of 420 subjects where 255 were identified and enrolled into the study, comprising 145 girls and 110 boys. The lateral cephalometric and panoramic radiographs were examined from the archives of the Department of Orthodontics, Aristotle University of Thessaloniki, Greece. Dental age was assessed according to the method of Demirjian, and skeletal maturation according to the Cervical Vertebral Maturation Method. Statistical elaboration included Spearman Brown formula, descriptive statistics, Pearson’s correlation coefficient and regression analysis, paired samples t-test, and Spearman’s rho correlation coefficient. Results: Chronological and dental age showed a high correlation for both gender(r =0.741 for boys, r = 0.770 for girls, p<0.001). The strongest correlation was for the CVM Stage IV for both males (r=0.554) and females (r=0.68). The lowest correlation was for the CVM Stage III in males (r=0.433, p<0.001) and for the CVM Stage II in females (r=0.393, p>0.001). The t-test revealed statistically significant differences between these variables (p<0.001) during the peak period. A statistically significant correlation (p<0.001) between tooth calcification and CVM stages was determined. The second molars showed the highest correlation with CVM stages (CVMS) (r= 0.65 for boys, r = 0.72 for girls). Conclusion: Dental age was more advanced than chronological for both boys and girls for all CVMS. During the peak period these differences were more pronounced. Moreover, all correlations between skeletal and dental stages were statistically significant. The second molars showed the highest correlation whereas the canines showed the lowest correlation for both gender. PMID:27335610

  5. Clinical correlation between the 6-min walk test andcardiopulmonary exercise testing in patients with pulmonary arterial hypertension.

    PubMed

    Acar, Serap; Savcı, Sema; Kardibak, Didem; Özcan Kahraman, Buse; Akdeniz, Bahri; Özpelit, Ebru; Sevinç, Can

    2016-12-20

    The aims of the present study were to assess the relationship between the distance walked during the 6-min walk test (6MWT) and exercise capacity as determined by cardiopulmonary exercise testing (CPET) in patients with pulmonary arterial hypertension (PAH) and to investigate the prognostic value of the 6MWT in comparison to clinical parameters of CPET and echocardiography findings. Thirty PAH patients participated in the study. Subject characteristics and New York Heart Association (NYHA) classifications were recorded. All subjects completed the 6MWT and CPET. Relationships among the variables were analyzed by the Pearson correlation test. Correlation coefficients between 6MWT distance and other variables were determined by linear regression analysis. Distance walked in the 6MWT was significantly correlated with the following exercise parameters: peak oxygen consumption, work load, and metabolic equivalents. Additionally, cardiac index was correlated with peak oxygen consumption and metabolic equivalents. We also showed that cardiac index and age were two significant determinants for exercise performance, accounting for 35.4% of the variance in the 6MWT. The 6MWT provides information that may be a better index for the patient's NYHA functional class determination than maximal exercise testing.

  6. Evaluation of Lama glama semen viscosity with a cone-plate rotational viscometer.

    PubMed

    Casaretto, C; Martínez Sarrasague, M; Giuliano, S; Rubin de Celis, E; Gambarotta, M; Carretero, I; Miragaya, M

    2012-05-01

    Llama semen is highly viscous. This characteristic is usually evaluated subjectively by measuring the thread formed when carefully pippeting a sample of semen. The aims of this study were (i) to objectively determine and analyse llama semen viscosity, (ii) to compare semen viscosity between ejaculates of the same male as well as between different males, (iii) to study the correlation between viscosity and other semen characteristics and (iv) to evaluate the effect of collagenase on semen viscosity. Semen viscosity was evaluated using a cone-plate Brookfield rotational viscometer. A non Newtonian, pseudoplastic behaviour was observed in the 45 semen samples evaluated. Rheological parameters were determined obtaining the following results (mean ± SD): apparent viscosity at 11.5 s(-1): 46.71 ± 26.8 cpoise and at 115 s(-1): 12.61 ± 4.1 cpoise; structural viscosity (K) (dyne s cm(-2)): 2.18 ± 1.4 and coefficient of consistency (n): 0.45 ± 0.1. Statistical differences were found between different ejaculates of the same male for structural viscosity and apparent viscosity at 11.5 s(-1) (P < 0.01). Correlation was found only between coefficient of consistency (n) and sperm concentration (P < 0.01). Significant differences for coefficient of consistency (n) and viscosity at 115 s(-1) were found between samples incubated with and without collagenase (P < 0.05). © 2011 Blackwell Verlag GmbH.

  7. Sample Size Estimation in Cluster Randomized Educational Trials: An Empirical Bayes Approach

    ERIC Educational Resources Information Center

    Rotondi, Michael A.; Donner, Allan

    2009-01-01

    The educational field has now accumulated an extensive literature reporting on values of the intraclass correlation coefficient, a parameter essential to determining the required size of a planned cluster randomized trial. We propose here a simple simulation-based approach including all relevant information that can facilitate this task. An…

  8. Modeling Demand for Unionization with Nontraditional Data Analysis Methods

    ERIC Educational Resources Information Center

    DeGroot, Timothy

    2006-01-01

    Upon reviewing the extant literature on determinants of unionism, it becomes clear that many areas that have had a plethora of research attention do not converge upon singularly directional findings. This study explores a potential cause of such an apparent anomaly: nonlinearity of data. An exploratory examination of correlation coefficients among…

  9. Measuring Perceived Educational Impact of a Resident-Led Research Newsletter.

    PubMed

    Aftab, Awais; Lackamp, Jeanne; Cerny, Cathleen

    2017-06-01

    To determine the perceived educational impact of a resident-led psychiatry research newsletter ('Research Watch') on the psychiatry residents at the authors' residency program. An anonymous, voluntary paper questionnaire was distributed to all psychiatry residents at the program. The survey inquired about the degree of exposure (quantified as 'exposure index') and contribution to the newsletter. A set of questions asked residents to estimate how much of the improvement they attributed to the influence of the newsletter, rating the attribution between 0 and 100%, in the areas of interest in scholarly activities/research, knowledge of current psychiatric research, and participation in scholarly activities/research. The survey also inquired if the newsletter had any impact on their clinical practice. Of 29 residents in the program who received the survey, 27 (93%) responded. The percentage of residents reporting perceived non-zero impact of the newsletter on specific areas of improvement was as follows: interest in scholarly activities/research (44%), knowledge of current psychiatric research (48%), participation in scholarly activities/research (40%), and clinical practice (40%). Exposure index significantly and positively correlated with self-reported percentage attribution for knowledge (correlation coefficient 0.422, p value 0.028) and self-reported impact on clinical practice (correlation coefficient 0.660, p value 0.000), and degree of contribution significantly and positively correlated with self-reported percentage attribution for knowledge (correlation coefficient 0.488, p value 0.010). A resident-led research newsletter can have a positive perceived impact on the residents' interest, knowledge, and participation in research, as well as a positive perceived impact on clinical practice.

  10. Correlation between lung to thorax transverse area ratio and observed/expected lung area to head circumference ratio in fetuses with left-sided diaphragmatic hernia.

    PubMed

    Hidaka, Nobuhiro; Murata, Masaharu; Sasahara, Jun; Ishii, Keisuke; Mitsuda, Nobuaki

    2015-05-01

    Observed/expected lung area to head circumference ratio (o/e LHR) and lung to thorax transverse area ratio (LTR) are the sonographic indicators of postnatal outcome in fetuses with congenital diaphragmatic hernia (CDH), and they are not influenced by gestational age. We aimed to evaluate the relationship between these two parameters in the same subjects with fetal left-sided CDH. Fetuses with left-sided CDH managed between 2005 and 2012 were included. Data of LTR and o/e LHR values measured on the same day prior to 33 weeks' gestation in target fetuses were retrospectively collected. The correlation between the two parameters was estimated using the Spearman's rank-correlation coefficient, and linear regression analysis was used to assess the relationship between them. Data on 61 measurements from 36 CDH fetuses were analyzed to obtain a Spearman's rank-correlation coefficient of 0.74 with the following linear equation: LTR = 0.002 × (o/e LHR) + 0.005. The determination coefficient of this linear equation was sufficiently high at 0.712, and the prediction accuracy obtained with this regression formula was considered satisfactory. A good linear correlation between the LTR and the o/e LHR was obtained, suggesting that we can translate the predictive parameters for each other. This information is expected to be useful to improve our understanding of different investigations focusing on LTR or o/e LHR as a predictor of postnatal outcome in CDH. © 2014 Japanese Teratology Society.

  11. Breast density estimation from high spectral and spatial resolution MRI

    PubMed Central

    Li, Hui; Weiss, William A.; Medved, Milica; Abe, Hiroyuki; Newstead, Gillian M.; Karczmar, Gregory S.; Giger, Maryellen L.

    2016-01-01

    Abstract. A three-dimensional breast density estimation method is presented for high spectral and spatial resolution (HiSS) MR imaging. Twenty-two patients were recruited (under an Institutional Review Board--approved Health Insurance Portability and Accountability Act-compliant protocol) for high-risk breast cancer screening. Each patient received standard-of-care clinical digital x-ray mammograms and MR scans, as well as HiSS scans. The algorithm for breast density estimation includes breast mask generating, breast skin removal, and breast percentage density calculation. The inter- and intra-user variabilities of the HiSS-based density estimation were determined using correlation analysis and limits of agreement. Correlation analysis was also performed between the HiSS-based density estimation and radiologists’ breast imaging-reporting and data system (BI-RADS) density ratings. A correlation coefficient of 0.91 (p<0.0001) was obtained between left and right breast density estimations. An interclass correlation coefficient of 0.99 (p<0.0001) indicated high reliability for the inter-user variability of the HiSS-based breast density estimations. A moderate correlation coefficient of 0.55 (p=0.0076) was observed between HiSS-based breast density estimations and radiologists’ BI-RADS. In summary, an objective density estimation method using HiSS spectral data from breast MRI was developed. The high reproducibility with low inter- and low intra-user variabilities shown in this preliminary study suggest that such a HiSS-based density metric may be potentially beneficial in programs requiring breast density such as in breast cancer risk assessment and monitoring effects of therapy. PMID:28042590

  12. Toxic trace elements in maternal and cord blood and social determinants in a Bolivian mining city.

    PubMed

    Barbieri, Flavia L; Gardon, Jacques; Ruiz-Castell, María; Paco V, Pamela; Muckelbauer, Rebecca; Casiot, Corinne; Freydier, Rémi; Duprey, Jean-Louis; Chen, Chih-Mei; Müller-Nordhorn, Jacqueline; Keil, Thomas

    2016-01-01

    This study assessed lead, arsenic, and antimony in maternal and cord blood, and associations between maternal concentrations and social determinants in the Bolivian mining city of Oruro using the baseline assessment of the ToxBol/Mine-Niño birth cohort. We recruited 467 pregnant women, collecting venous blood and sociodemographic information as well as placental cord blood at birth. Metallic/semimetallic trace elements were measured using inductively coupled plasma mass spectrometry. Lead medians in maternal and cord blood were significantly correlated (Spearman coefficient = 0.59; p < 0.001; 19.35 and 13.50 μg/L, respectively). Arsenic concentrations were above detection limit (3.30 μg/L) in 17.9% of maternal and 34.6% of cord blood samples. They were not associated (Fischer's p = 0.72). Antimony medians in maternal and cord blood were weakly correlated (Spearman coefficient = 0.15; p < 0.03; 9.00 and 8.62 μg/L, respectively). Higher concentrations of toxic elements in maternal blood were associated with maternal smoking, low educational level, and partner involved in mining.

  13. 40 CFR 53.34 - Test procedure for methods for PM10 and Class I methods for PM2.5.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... linear regression parameters (slope, intercept, and correlation coefficient) describing the relationship... correlation coefficient. (2) To pass the test for comparability, the slope, intercept, and correlation...

  14. On the correlation between bond-length change and vibrational frequency shift in halogen-bonded complexes

    NASA Astrophysics Data System (ADS)

    Wang, Weizhou; Zhang, Yu; Ji, Baoming; Tian, Anmin

    2011-06-01

    The C-Hal (Hal = Cl, Br, or I) bond-length change and the corresponding vibrational frequency shift of the C-Hal stretch upon the C-Hal ⋯Y (Y is the electron donor) halogen bond formation have been determined by using density functional theory computations. Plots of the C-Hal bond-length change versus the corresponding vibrational frequency shift of the C-Hal stretch all give straight lines. The coefficients of determination range from 0.94366 to 0.99219, showing that the correlation between the C-Hal bond-length change and the corresponding frequency shift is very good in the halogen-bonded complexes. The possible effects of vibrational coupling, computational method, and anharmonicity on the bond-length change-frequency shift correlation are discussed in detail.

  15. [Prediction of soil adsorption coefficients of organic compounds in a wide range of soil types by soil column liquid chromatography].

    PubMed

    Guo, Rongbo; Chen, Jiping; Zhang, Qing; Wu, Wenzhong; Liang, Xinmiao

    2004-01-01

    Using the methanol-water mixtures as mobile phases of soil column liquid chromatography (SCLC), prediction of soil adsorption coefficients (K(d)) by SCLC was validated in a wide range of soil types. The correlations between the retention factors measured by SCLC and soil adsorption coefficients measured by batch experiments were studied for five soils with different properties, i.e., Eurosoil 1#, 2#, 3#, 4# and 5#. The results show that good correlations existed between the retention factors and soil adsorption coefficients for Eurosoil 1#, 2#, 3# and 4#. For Eurosoil 5# which has a pH value of near 3, the correlation between retention factors and soil adsorption coefficients was unsatisfactory using methanol-water as mobile phase of SCLC. However, a good correlation was obtained using a methanol-buffer mixture with pH 3 as the mobile phase. This study proved that the SCLC is suitable for the prediction of soil adsorption coefficients.

  16. Evaluation of two portable meters for determination of blood triglyceride concentration in dogs.

    PubMed

    Kluger, Elissa K; Dhand, Navneet K; Malik, Richard; Ilkin, William J; Snow, David H; Govendir, Merran

    2010-02-01

    To evaluate agreement between 2 portable triglyceride meters and a veterinary laboratory for measurement of blood triglyceride concentrations in dogs and evaluate effects of Hct and blood volume analyzed. 97 blood samples collected from 60 dogs. Triglyceride concentrations were measured in blood by use of 2 meters and compared with serum triglyceride concentrations determined by a veterinary laboratory. Within- and between-day precision, accuracy, and effects of blood volume and Hct were analyzed. Accuracy of both meters varied with triglyceride concentration, although both accurately delineated dogs with triglyceride concentrations < 180 mg/dL versus > or = 180 mg/dL. One meter had results with excellent overall correlation with results of the standard laboratory method, with a concordance correlation coefficient of 0.94 and mean difference of 20.3 mg/dL. The other meter had a good overall concordance correlation coefficient of 0.86 with a higher absolute mean difference of -27.7 mg/dL. Results were only affected by blood volume; triglyceride concentrations determined via both meters were significantly lower when 7 microL of EDTA-anticoagulated blood was used, compared with larger volumes. 1 meter had greater accuracy in the range of 140 to 400 mg/dL and was therefore well suited to detect hypertriglyceridemia. The other meter was accurate with triglyceride values < 140 mg/dL and yielded results similar to those of the veterinary laboratory in the range of 140 to 400 mg/dL, therefore being suitable for determination of triglyceride concentrations in nonfed dogs and dogs with mildly high concentrations.

  17. Structural parameters associated with location of peaks of peripapillary retinal nerve fiber layer thickness in young healthy eyes.

    PubMed

    Yamashita, Takehiro; Asaoka, Ryo; Kii, Yuya; Terasaki, Hiroto; Murata, Hiroshi; Sakamoto, Taiji

    2017-01-01

    The location of the peaks of the circumpapillary retinal nerve fiber layer (cpRNFL) thickness is affected by several ocular parameters. In this study, we have generated equations that can determine the peaks of the cpRNFL. This study was a prospective, observational, cross sectional study of 118 healthy right eyes. The axial length, optic disc tilt, superiortemporal (ST)- and inferiortemporal (IT)-peaks of the cpRNFL thickness, and angles of the ST and IT retinal arteries (RA) and veins (RV) were determined. The correlations between the location of the ST- and IT-peaks and ocular structural parameters and the sex, body height and weight were calculated. The best fit equations to generate the location of the ST/IT-peaks were determined using corrected-Akaike Information Criteria. The location of the ST-peak was 0.72+(0.40 x ST-RA)+(0.27 x ST-RV)+(0.14 x height)-(0.47 x papillo-macular-position)-(0.11 x disc tilt) with a coefficient of correlation of 0.61 (P<0.0001). The location of the IT-peak was 21.88+(0.53 x IT-RA)+(0.15 x IT-RV)+(0.041 x corneal thickness)-(1.00 x axial length) with a coefficient of correlation of 0.59 (P<0.0001). The location of ST/IT peaks is determined by different parameters of the ocular structure. These equations allow clinicians to obtain an accurate location of the peaks for a more accurate diagnosis of glaucoma.

  18. Thermophysical Properties of Ionic Liquid, 1-Pentyl-3-methylimidazolium Chloride in Water at Different Temperatures

    NASA Astrophysics Data System (ADS)

    Shekaari, Hemayat; Mousavi, Sedighehnaz S.; Mansoori, Yagoub

    2009-04-01

    Osmotic coefficients, {φ}, electrical conductance data, Λ, and refractive indices, n D, of aqueous solutions of the ionic liquid, 1-pentyl-3-methylimidazolium chloride [PnMIm]Cl have been measured at T = (298.15, 308.15, 318.15, and 328.15) K. Measurements of osmotic coefficients were carried out by the vapor-pressure osmometry method (VPO). Osmotic coefficient values show that ion-solvent interactions are stronger at lower temperature. The osmotic coefficients were correlated to the Pitzer-ion interaction and modified NRTL (MNRTL) models. From these data, mean molal activity coefficients, γ±, and excess Gibbs free energies, G E, have been calculated. Electrical conductance data have been applied for determination of association constants, K a, and limiting molar conductances, Λ 0, using the low concentration chemical model (lcCM). Calculated ion-association constant, K a, values show that ion-association effects increase at high temperatures which is in agreement with osmotic coefficient results. Experimental results of refractive indices for the binary system are reported, and have been fitted by a polynomial expansion.

  19. Is coverage a factor in non-Gaussianity of IMF parameters?

    NASA Technical Reports Server (NTRS)

    Ahluwalia, H. S.; Fikani, M. M.

    1995-01-01

    Recently, Feynman and Ruzmaikin (1994) showed that IMF parameters for the 1973 to 1990 period are not log-normally distributed as previously suggested by Burlaga and King (1979) for the data obtained over a shorter time period (1963-75). They studied the first four moments, namely: mean, variance, skewness, and kurtosis. For a Gaussian distribution, moments higher than the variance should vanish. In particular, Feynman and Ruzmaikin obtained very high values of kurtosis during some periods of their analysis. We note that the coverage for IMF parameters is very uneven for the period analyzed by them, ranging from less than 40% to greater than 80%. So a question arises as to whether the amount of coverage is a factor in their analysis. We decided to test this for the B(sub z) component of IMF, since it is an effective geoactive parameter for short term disturbances. Like them, we used 1-hour averaged data available on the Omnitape. We studied the scatter plots of the annual mean values of B(sub z)(nT) and its kurtosis versus the percent coverage for the year. We obtain a correlation coefficient of 0.48 and 0.42 respectively for the 1973-90 period. The probability for a chance occurrence of these correlation coefficients for 18 pair of points is less than 8%. As a rough measure of skewness, we determined the percent asymmetry between the areas of the histograms representing the distributions of the positive and the negative values of B(sub z) and studied its correlation with the coverage for the year. This analysis yields a correlation coefficient of 0.41 When we extended the analysis for the whole period for which IMF data are available (1963-93) the corresponding correlation coefficients are 0.59, 0.14, and 0.42. Our findings will be presented and discussed

  20. High inter-rater reliability, agreement, and convergent validity of Constant score in patients with clavicle fractures.

    PubMed

    Ban, Ilija; Troelsen, Anders; Kristensen, Morten Tange

    2016-10-01

    The Constant score (CS) has been the primary endpoint in most studies on clavicle fractures. However, the CS was not developed to assess patients with clavicle fractures. Our aim was to examine inter-rater reliability and agreement of the CS in patients with clavicle fractures. The secondary aim was to estimate the correlation between the CS and the Disabilities of the Arm, Shoulder and Hand score and the internal consistency of the 2 scores. On the basis of sample sizing, 36 patients (31 male and 5 female patients; mean age, 41.3 years) with clavicle fractures underwent standardized CS assessment at a mean of 6.8 weeks (SD, 1.0 weeks) after injury. Reliability and agreement of the CS were determined by 2 raters. The interclass correlation coefficient (ICC2,1), standard error of measurement, minimal detectable change, Cronbach α coefficient, and Pearson correlation coefficient were estimated. Inter-rater reliability of the total CS was excellent (interclass correlation coefficient, 0.94; 95% confidence interval, 0.88-0.97), with no systematic difference between the 2 raters (P = .75). The standard error of measurement (measurement error at the group level) was 4.9, whereas the minimal detectable change (smallest change needed to indicate a real change for an individual) was 13.6 CS points. The internal consistency of the 10 CS items was good, with a Cronbach α of .85, and we found a strong correlation (r = -0.92) between the CS and Disabilities of the Arm, Shoulder and Hand score. The CS was found to be reliable for assessing patients with clavicle fractures, especially at the group level. With high inter-rater reliability and agreement, in addition to good internal consistency, the standardized CS used in this study can be used for comparison of results from different settings. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  1. Model for the partition of neutral compounds between n-heptane and formamide.

    PubMed

    Karunasekara, Thushara; Poole, Colin F

    2010-04-01

    Partition coefficients for 84 varied compounds were determined for n-heptane-formamide biphasic partition system and used to derive a model for the distribution of neutral compounds between the n-heptane-rich and formamide-rich layers. The partition coefficients, log K(p), were correlated through the solvation parameter model giving log K(p)=0.083+0.559E-2.244S-3.250A-1.614B+2.387V with a multiple correlation coefficient of 0.996, standard error of the estimate 0.139, and Fisher statistic 1791. In the model, the solute descriptors are excess molar refraction, E, dipolarity/polarizability, S, overall hydrogen-bond acidity, A, overall hydrogen-bond basicity, B, and McGowan's characteristic volume, V. The model is expected to be able to estimate further values of the partition coefficient to about 0.13 log units for the same descriptor space covered by the calibration compounds (E=-0.26-2.29, S=0-1.93, A=0-1.25, B=0.02-1.58, and V=0.78-2.50). The n-heptane-formamide partition system is shown to have different selectivity to other totally organic biphasic systems and to be suitable for estimating descriptor values for compounds of low water solubility and/or stability.

  2. Determining areas that require indoor insecticide spraying using Multi Criteria Evaluation, a decision-support tool for malaria vector control programmes in the Central Highlands of Madagascar

    PubMed Central

    Rakotomanana, Fanjasoa; Randremanana, Rindra V; Rabarijaona, Léon P; Duchemin, Jean Bernard; Ratovonjato, Jocelyn; Ariey, Frédéric; Rudant, Jean Paul; Jeanne, Isabelle

    2007-01-01

    Background The highlands of Madagascar present an unstable transmission pattern of malaria. The population has no immunity, and the central highlands have been the sites of epidemics with particularly high fatality. The most recent epidemic occurred in the 1980s, and caused about 30,000 deaths. The fight against malaria epidemics in the highlands has been based on indoor insecticide spraying to control malaria vectors. Any preventive programme involving generalised cover in the highlands will require very substantial logistical support. We used multicriteria evaluation, by the method of weighted linear combination, as basis for improved targeting of actions by determining priority zones for intervention. Results Image analysis and field validation showed the accuracy of mapping rice fields to be between 82.3% and 100%, and the Kappa coefficient was 0.86 to 0.99. A significant positive correlation was observed between the abundance of the vector Anopheles funestus and temperature; the correlation coefficient was 0.599 (p < 0.001). A significant negative correlation was observed between vector abundance and human population density: the correlation coefficient was -0.551 (p < 0.003). Factor weights were determined by pair-wise comparison and the consistency ratio was 0.04. Risk maps of the six study zones were obtained according to a gradient of risk. Nine of thirteen results of alert confirmed by the Epidemiological Surveillance Post were in concordance with the risk map. Conclusion This study is particularly valuable for the management of vector control programmes, and particularly the reduction of the vector population with a view to preventing disease. The risk map obtained can be used to identify priority zones for the management of resources, and also help avoid systematic and generalised spraying throughout the highlands: such spraying is particularly difficult and expensive. The accuracy of the mapping, both as concerns time and space, is dependent on the availability of data. Continuous monitoring of malaria transmission factors must be undertaken to detect any changes. A regular case notification allows risk map to be verified. These actions should therefore be implemented so that risk maps can be satisfactorily assessed. PMID:17261177

  3. Temporal correlation coefficient for directed networks.

    PubMed

    Büttner, Kathrin; Salau, Jennifer; Krieter, Joachim

    2016-01-01

    Previous studies dealing with network theory focused mainly on the static aggregation of edges over specific time window lengths. Thus, most of the dynamic information gets lost. To assess the quality of such a static aggregation the temporal correlation coefficient can be calculated. It measures the overall possibility for an edge to persist between two consecutive snapshots. Up to now, this measure is only defined for undirected networks. Therefore, we introduce the adaption of the temporal correlation coefficient to directed networks. This new methodology enables the distinction between ingoing and outgoing edges. Besides a small example network presenting the single calculation steps, we also calculated the proposed measurements for a real pig trade network to emphasize the importance of considering the edge direction. The farm types at the beginning of the pork supply chain showed clearly higher values for the outgoing temporal correlation coefficient compared to the farm types at the end of the pork supply chain. These farm types showed higher values for the ingoing temporal correlation coefficient. The temporal correlation coefficient is a valuable tool to understand the structural dynamics of these systems, as it assesses the consistency of the edge configuration. The adaption of this measure for directed networks may help to preserve meaningful additional information about the investigated network that might get lost if the edge directions are ignored.

  4. Correlation characteristics of phase and amplitude chimeras in an ensemble of nonlocally coupled maps

    NASA Astrophysics Data System (ADS)

    Vadivasova, T. E.; Strelkova, G. I.; Bogomolov, S. A.; Anishchenko, V. S.

    2017-01-01

    Correlation characteristics of chimera states have been calculated using the coefficient of mutual correlation of elements in a closed-ring ensemble of nonlocally coupled chaotic maps. Quantitative differences between the coefficients of mutual correlation for phase and amplitude chimeras are established for the first time.

  5. Relationship between rhinosinusitis symptoms and mucociliary clearance time.

    PubMed

    Boatsman, Justin E; Calhoun, Karen H; Ryan, Matthew W

    2006-03-01

    To determine the correlation between rhinosinusitis symptoms as assessed by the Sino-Nasal Outcomes Test-20 (SNOT-20) and mucociliary clearance as assessed by the saccharin method. This was a cross-sectional study of 50 adult volunteers. Subjects completed the SNOT-20, and mucociliary clearance was determined with the saccharine method. Correlation coefficients (Spearman's Rho) were calculated for the global SNOT-20 score. The SNOT-20 scores varied from 20 to 54 (mean 30.28) with a possible range of 20 to 100. Clearance times varied from 418 to 2865 seconds (mean 999). There was no significant correlation between global SNOT-20 score and clearance time (r = 0.196). There is no significant correlation between rhinosinusitis symptoms as assessed by SNOT-20 scores and mucociliary clearance. Mucociliary clearance is important for the health of the sinonasal cavities, but clearance time does not appear to be associated with symptom severity in the population studied. A-1b.

  6. Effect of disease progression on liver apparent diffusion coefficient values in a murine model of NASH at 11.7 Tesla MRI.

    PubMed

    Anderson, Stephan W; Soto, Jorge A; Milch, Holly N; Ozonoff, Al; O'Brien, Michael; Hamilton, James A; Jara, Hernan J

    2011-04-01

    To evaluate the apparent diffusion coefficient (ADC) values of liver in a murine model of non-alcoholic steatohepatitis using 11.7 Tesla (T) MRI. This animal study was IACUC approved. Seventeen male C57BL/6 mice were divided into control (n = 3) and experimental groups (n = 14) fed a methionine-deficient choline-deficient (MCD) diet to induce steatohepatitis. Livers underwent ex vivo diffusion-weighted MR imaging and ADC maps were calculated. A pathologist determined subjective scores of steatosis, classified from 0 to 3. Digital image analysis was used to determine percentage areas of steatosis. Graphs comparing ADC to subjective and digital image analysis (DIA) determinations of steatosis were plotted. Subjective assessments of steatosis ranged up to values of 3 and DIA determined areas of steatosis to range up to approximately 16%. ADC values approximated 800 × 10(-6) mm(2) /s (range, 749-811 × 10(-6) mm(2) /s, mean 786 × 10(-6) mm(2) /s) in controls and 500 × 10(-6) mm(2) /s (range, 478-733 × 10(-6) mm(2) /s, mean 625 × 10(-6) mm(2) /s) in experimental mice. Moderate correlation between ADC and subjective scores of steatosis (R = -0.56) was observed. Strong correlation between ADC values and percentage areas of steatosis was between ADC values and percentage areas of steatosis was observed greater (R = -0.81) and very strong correlation was observed with the exclusion of a single outlying data point (R = -0.91). Based on the comparison of ADC values and steatosis determinations by DIA, increasing degrees of steatosis are seen to result in decreased hepatic ADC values. Copyright © 2011 Wiley-Liss, Inc.

  7. Use of the Vettest 8008 and refractometry for determination of total protein, albumin, and globulin concentrations in feline effusions.

    PubMed

    Papasouliotis, Kostas; Murphy, Kate; Dodkin, Steve; Torrance, Andy G

    2002-01-01

    Pleural and peritoneal effusion is a common clinical finding in feline practice. Determination of fluid albumin (ALB) and globulin (GLOB) concentrations in addition to total protein (TP) concentration can be helpful in diagnosing or ruling out certain diseases in cats, especially feline infectious peritonitis (FIP). The objective of this study was to compare effusion TP, ALB, and GLOB results obtained by a refractometer and a bench-top dry chemistry analyzer with those results obtained by a reference method. Twenty-six pleural and 14 peritoneal effusion samples were analyzed from 40 cats with various diseases. TP and ALB concentrations were determined by a reference automated wet chemistry analyzer (Kone Specific, Kone Instruments, Espoo, Finland), a bench-top dry chemistry analyzer (Vettest 8008, IDEXX Laboratories Ltd, Chalfont St Peter, UK), and a refractometer (Atago SPR-T2, Atago Co, Tokyo, Japan). GLOB, albumin to globulin (A/G) ratio, and globulins as a percentage of total proteins (GLOB%) were calculated. Results were analyzed by paired t tests, difference plots, and Deming s regression analysis. Correlation coefficients (r) for TP with Vettest versus Kone and refractometer versus Kone methods were.97 and.94, respectively. GLOB and GLOB% values were significantly higher and A/G ratios were significantly lower with Vettest versus Kone methods. Correlation coefficients for ALB, GLOB, GLOB% and A/G ratio with Vettest versus Kone methods were.86,.93,.82, and.73, respectively. Although correlation with other methods was good, the refractometer underestimated TP concentrations in 3 samples. The refractometer is an acceptable method for determination of TP concentration in feline effusions. The Vettest 8008 also is an acceptable method for the determination of TP and ALB concentrations, however, calculated A/G ratios obtained with the Vettest are unacceptable.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kok, H. Petra, E-mail: H.P.Kok@amc.uva.nl; Ciampa, Silvia; Department of Civil Engineering and Computer Science, University of Rome Tor Vergata, Rome

    Purpose: Hyperthermia is the clinical application of heat, in which tumor temperatures are raised to 40°C to 45°C. This proven radiation and chemosensitizer significantly improves clinical outcome for several tumor sites. Earlier studies of the use of pre-treatment planning for hyperthermia showed good qualitative but disappointing quantitative reliability. The purpose of this study was to investigate whether hyperthermia treatment planning (HTP) can be used more reliably for online adaptive treatment planning during locoregional hyperthermia treatments. Methods and Materials: This study included 78 treatment sessions for 15 patients with non-muscle-invasive bladder cancer. At the start of treatments, temperature rise measurements weremore » performed with 3 different antenna settings optimized for each patient, from which the absorbed power (specific absorption rate [SAR]) was derived. HTP was performed based on a computed tomography (CT) scan in treatment position with the bladder catheter in situ. The SAR along the thermocouple tracks was extracted from the simulated SAR distributions. Correlations between measured and simulated (average) SAR values were determined. To evaluate phase steering, correlations between the changes in simulated and measured SAR values averaged over the thermocouple probe were determined for all 3 combinations of antenna settings. Results: For 42% of the individual treatment sessions, the correlation coefficient between measured and simulated SAR profiles was higher than 0.5, whereas 58% showed a weak correlation (R of <0.5). The overall correlation coefficient between measured and simulated average SAR was weak (R=0.31; P<.001). The measured and simulated changes in average SAR after adapting antenna settings correlated much better (R=0.70; P<.001). The ratio between the measured and simulated quotients of maximum and average SARs was 1.03 ± 0.26 (mean ± SD), indicating that HTP can also correctly predict the relative amplitude of SAR peaks. Conclusions: HTP can correctly predict SAR changes after adapting antenna settings during hyperthermia treatments. This allows online adaptive treatment planning, assisting the operator in determining antenna settings resulting in increased tumor temperatures.« less

  9. Experimental study of flow distribution and pressure loss with circumferential inlet and outlet manifolds

    NASA Technical Reports Server (NTRS)

    Dittrich, R. T.

    1972-01-01

    Water flow tests with circumferential inlet and outlet manifolds were conducted to determine factors affecting fluid distribution and pressure losses. Various orifice sizes and manifold geometries were tested over a range of flow velocities. With inlet manifolds, flow distribution was related directly to orifice discharge coefficients. A correlation indicated that nonuniform distribution resulted when the velocity head ratio at the orifice was not in the range of constant discharge coefficient. With outlet manifolds, nonuniform flow was related to static pressure variations along the manifold. Outlet manifolds had appreciably greater pressure losses than comparable inlet manifolds.

  10. Methods for recalibration of mass spectrometry data

    DOEpatents

    Tolmachev, Aleksey V [Richland, WA; Smith, Richard D [Richland, WA

    2009-03-03

    Disclosed are methods for recalibrating mass spectrometry data that provide improvement in both mass accuracy and precision by adjusting for experimental variance in parameters that have a substantial impact on mass measurement accuracy. Optimal coefficients are determined using correlated pairs of mass values compiled by matching sets of measured and putative mass values that minimize overall effective mass error and mass error spread. Coefficients are subsequently used to correct mass values for peaks detected in the measured dataset, providing recalibration thereof. Sub-ppm mass measurement accuracy has been demonstrated on a complex fungal proteome after recalibration, providing improved confidence for peptide identifications.

  11. Fuel Property Determination of Biodiesel-Diesel Blends By Terahertz Spectrum

    NASA Astrophysics Data System (ADS)

    Zhao, Hui; Zhao, Kun; Bao, Rima

    2012-05-01

    The frequency-dependent absorption characteristics of biodiesel and its blends with conventional diesel fuel have been researched in the spectral range of 0.2-1.5 THz by the terahertz time-domain spectroscopy (THz-TDS). The absorption coefficient presented a regular increasing with biodiesel content. A nonlinear multivariate model that correlating cetane number and solidifying point of bio-diesel blends with absorption coefficient has been established, making the quantitative analysis of fuel properties simple. The results made the cetane number and solidifying point prediction possible by THz-TDS technology and indicated a bright future in practical application.

  12. The functional correlation between rainfall rate and extinction coefficient for frequencies from 3 to 10 GHz

    NASA Technical Reports Server (NTRS)

    Jameson, A. R.

    1990-01-01

    The relationship between the rainfall rate (R) obtained from radiometric brightness temperatures and the extinction coefficient (k sub e) is investigated by computing the values of k sub e over a wide range of rainfall rates, for frequencies from 3 to 25 GHz. The results show that the strength of the relation between the R and the k sub e values exhibits considerable variation for frequencies at this range. Practical suggestions are made concerning the selection of particular frequencies for rain measurements to minimize the error in R determinations.

  13. Channel correlation of free space optical communication systems with receiver diversity in non-Kolmogorov atmospheric turbulence

    NASA Astrophysics Data System (ADS)

    Ma, Jing; Fu, Yulong; Tan, Liying; Yu, Siyuan; Xie, Xiaolong

    2018-05-01

    Spatial diversity as an effective technique to mitigate the turbulence fading has been widely utilized in free space optical (FSO) communication systems. The received signals, however, will suffer from channel correlation due to insufficient spacing between component antennas. In this paper, the new expressions of the channel correlation coefficient and specifically its components (the large- and small-scale channel correlation coefficients) for a plane wave with aperture effects are derived for horizontal link in moderate-to-strong turbulence, using a non-Kolmogorov spectrum that has a generalized power law in the range of 3-4 instead of the fixed classical Kolmogorov power law of 11/3. And then the influence of power law variations on the channel correlation coefficient and its components are analysed. The numerical results indicated that various value of the power law lead to varying effects on the channel correlation coefficient and its components. This work will help with the further investigation on the fading correlation in spatial diversity systems.

  14. Accuracy of a Radiological Evaluation Method for Thoracic and Lumbar Spinal Curvatures Using Spinous Processes.

    PubMed

    Marchetti, Bárbara V; Candotti, Cláudia T; Raupp, Eduardo G; Oliveira, Eduardo B C; Furlanetto, Tássia S; Loss, Jefferson F

    The purpose of this study was to assess a radiographic method for spinal curvature evaluation in children, based on spinous processes, and identify its normality limits. The sample consisted of 90 radiographic examinations of the spines of children in the sagittal plane. Thoracic and lumbar curvatures were evaluated using angular (apex angle [AA]) and linear (sagittal arrow [SA]) measurements based on the spinous processes. The same curvatures were also evaluated using the Cobb angle (CA) method, which is considered the gold standard. For concurrent validity (AA vs CA), Pearson's product-moment correlation coefficient, root-mean-square error, Pitman- Morgan test, and Bland-Altman analysis were used. For reproducibility (AA, SA, and CA), the intraclass correlation coefficient, standard error of measurement, and minimal detectable change measurements were used. A significant correlation was found between CA and AA measurements, as was a low root-mean-square error. The mean difference between the measurements was 0° for thoracic and lumbar curvatures, and the mean standard deviations of the differences were ±5.9° and 6.9°, respectively. The intraclass correlation coefficients of AA and SA were similar to or higher than the gold standard (CA). The standard error of measurement and minimal detectable change of the AA were always lower than the CA. This study determined the concurrent validity, as well as intra- and interrater reproducibility, of the radiographic measurements of kyphosis and lordosis in children. Copyright © 2017. Published by Elsevier Inc.

  15. Correlation and path coefficient analysis of quantitative characters in spine gourd (Momordica dioica Roxb.).

    PubMed

    Aliya, F; Begum, H; Reddy, M T; Sivaraj, N; Pandravada, S R; Narshimulu, G

    2014-05-01

    Fifty genotypes of spine gourd (Momordica dioica Roxb.) were evaluated in a randomized block design with two replications at the Vegetable Research Station, Rajendranagar, Hyderabad, Andhra Pradesh, India during kharif, 2012. Correlation and path coefficient analysis were carried out to study the character association and contribution, respectively for twelve quantitative characters namely vine length (m), number of stems per plant, days to first female flower appearance, first female flowering node, days to first fruit harvest, days to last fruit harvest, fruiting period (days), fruit length (cm), fruit width (cm), fruit weight (g), number of fruits per plant and fruit yield per plant (kg) for identification of the potential selection indices. Correlation and path coefficient analyses revealed that fruiting period and number of fruits per plant not only had positively significant correlation with fruit yield but also had positively high direct effect on it and are regarded as the main determinants of fruit yield. Days to first fruit harvest had positively moderate direct effect on fruit yield and its association was negatively significant, days to last fruit harvest had negatively high direct effect on fruit yield and its association was significant positively, hence restricted simultaneous selection can be made for days to first fruit harvest and days to last fruit harvest. The improvement in fruit yield can be effective if selection is based on days to first fruit harvest, days to last fruit harvest, fruiting period and number of fruits per plant.

  16. Using fluorescence correlation spectroscopy to study conformational changes in denatured proteins.

    PubMed

    Sherman, Eilon; Itkin, Anna; Kuttner, Yosef Yehuda; Rhoades, Elizabeth; Amir, Dan; Haas, Elisha; Haran, Gilad

    2008-06-01

    Fluorescence correlation spectroscopy (FCS) is a sensitive analytical tool that allows dynamics and hydrodynamics of biomolecules to be studied under a broad range of experimental conditions. One application of FCS of current interest is the determination of the size of protein molecules in the various states they sample along their folding reaction coordinate, which can be accessed through the measurement of diffusion coefficients. It has been pointed out that the analysis of FCS curves is prone to artifacts that may lead to erroneous size determination. To set the stage for FCS studies of unfolded proteins, we first show that the diffusion coefficients of small molecules as well as proteins can be determined accurately even in the presence of high concentrations of co-solutes that change the solution refractive index significantly. Indeed, it is found that the Stokes-Einstein relation between the measured diffusion coefficient and solution viscosity holds even in highly concentrated glycerol or guanidinium hydrochloride (GuHCl) solutions. These measurements form the basis for an investigation of the structure of the denatured state of two proteins, the small protein L and the larger, three-domain protein adenylate kinase (AK). FCS is found useful for probing expansion in the denatured state beyond the unfolding transition. It is shown that the denatured state of protein L expands as the denaturant concentration increases, in a process akin to the transition from a globule to a coil in polymers. This process continues at least up to 5 M GuHCl. On the other hand, the denatured state of AK does not seem to expand much beyond 2 M GuHCl, a result that is in qualitative accord with single-molecule fluorescence histograms. Because both the unfolding transition and the coil-globule transition of AK occur at a much lower denaturant concentration than those of protein L, a possible correlation between the two phenomena is suggested.

  17. Are Predictive Equations for Estimating Resting Energy Expenditure Accurate in Asian Indian Male Weightlifters?

    PubMed

    Joseph, Mini; Gupta, Riddhi Das; Prema, L; Inbakumari, Mercy; Thomas, Nihal

    2017-01-01

    The accuracy of existing predictive equations to determine the resting energy expenditure (REE) of professional weightlifters remains scarcely studied. Our study aimed at assessing the REE of male Asian Indian weightlifters with indirect calorimetry and to compare the measured REE (mREE) with published equations. A new equation using potential anthropometric variables to predict REE was also evaluated. REE was measured on 30 male professional weightlifters aged between 17 and 28 years using indirect calorimetry and compared with the eight formulas predicted by Harris-Benedicts, Mifflin-St. Jeor, FAO/WHO/UNU, ICMR, Cunninghams, Owen, Katch-McArdle, and Nelson. Pearson correlation coefficient, intraclass correlation coefficient, and multiple linear regression analysis were carried out to study the agreement between the different methods, association with anthropometric variables, and to formulate a new prediction equation for this population. Pearson correlation coefficients between mREE and the anthropometric variables showed positive significance with suprailiac skinfold thickness, lean body mass (LBM), waist circumference, hip circumference, bone mineral mass, and body mass. All eight predictive equations underestimated the REE of the weightlifters when compared with the mREE. The highest mean difference was 636 kcal/day (Owen, 1986) and the lowest difference was 375 kcal/day (Cunninghams, 1980). Multiple linear regression done stepwise showed that LBM was the only significant determinant of REE in this group of sportspersons. A new equation using LBM as the independent variable for calculating REE was computed. REE for weightlifters = -164.065 + 0.039 (LBM) (confidence interval -1122.984, 794.854]. This new equation reduced the mean difference with mREE by 2.36 + 369.15 kcal/day (standard error = 67.40). The significant finding of this study was that all the prediction equations underestimated the REE. The LBM was the sole determinant of REE in this population. In the absence of indirect calorimetry, the REE equation developed by us using LBM is a better predictor for calculating REE of professional male weightlifters of this region.

  18. Correlation between cervical vertebral maturation and chronological age in a group of Iranian females.

    PubMed

    Safavi, Seyed Mohammadreza; Beikaii, Hanie; Hassanizadeh, Raheleh; Younessian, Farnaz; Baghban, Alireza Akbarzadeh

    2015-01-01

    Correlation between chronological age at different stages of cervical vertebral maturation (CVM) is important in clinical orthodontic practice. The objective of this study was to evaluate the correlation between CVM stage and chronological age in a group of Iranian female patients. This study was conducted on 196 digital lateral cephalometry of female patients with the age ranged 9-14 years. The CVM stage was determined with two calibrated examiners, using the method developed by Baccetti and its correlation with mean chronological age was assessed by the Spearman rank-order. The intra and inter-agreements were evaluated by weighted Kappa statistics in overall diagnosis of stages, in addition to determination of presence or absent of concavities at the lower border of second, third and fourth cervical vertebrae and the shapes of the third and fourth vertebrae. P < 0.05 was considered as significant. The correlation coefficient between CVM stages and chronological age was relatively low (r = 0.62). The least amount of inter-observer agreement was determined to be at the clinical decision of the shape of the fourth vertebra. Regarding the low reported correlation, the concomitant usage of other skeletal indicators seems necessary for precise determination of physiological age of the patients.

  19. The Physical Significance of the Synthetic Running Correlation Coefficient and Its Applications in Oceanic and Atmospheric Studies

    NASA Astrophysics Data System (ADS)

    Zhao, Jinping; Cao, Yong; Wang, Xin

    2018-06-01

    In order to study the temporal variations of correlations between two time series, a running correlation coefficient (RCC) could be used. An RCC is calculated for a given time window, and the window is then moved sequentially through time. The current calculation method for RCCs is based on the general definition of the Pearson product-moment correlation coefficient, calculated with the data within the time window, which we call the local running correlation coefficient (LRCC). The LRCC is calculated via the two anomalies corresponding to the two local means, meanwhile, the local means also vary. It is cleared up that the LRCC reflects only the correlation between the two anomalies within the time window but fails to exhibit the contributions of the two varying means. To address this problem, two unchanged means obtained from all available data are adopted to calculate an RCC, which is called the synthetic running correlation coefficient (SRCC). When the anomaly variations are dominant, the two RCCs are similar. However, when the variations of the means are dominant, the difference between the two RCCs becomes obvious. The SRCC reflects the correlations of both the anomaly variations and the variations of the means. Therefore, the SRCCs from different time points are intercomparable. A criterion for the superiority of the RCC algorithm is that the average value of the RCC should be close to the global correlation coefficient calculated using all data. The SRCC always meets this criterion, while the LRCC sometimes fails. Therefore, the SRCC is better than the LRCC for running correlations. We suggest using the SRCC to calculate the RCCs.

  20. Development of a label-free immunosensor system for detecting plasma cortisol levels in fish.

    PubMed

    Wu, Haiyun; Ohnuki, Hitoshi; Hibi, Kyoko; Ren, Huifeng; Endo, Hideaki

    2016-02-01

    Fishes display a wide variation in their physiological responses to stress, which is clearly evident in the plasma corticosteroid changes, chiefly cortisol levels in fish. In the present study, we describe a novel label-free immunosensor for detecting plasma cortisol levels. The method is based on immunologic reactions and amperometric measurement using cyclic voltammetry. For the immobilization of the antibody on the surface of sensing electrode, we used a self-assembled monolayer of thiol-containing compounds. Using this electrode, we detect the CV signal change caused by the generation of antigen-antibody complex. The immunosensor showed a response to cortisol levels, and the anodic peak value linearly decreased with a correlation coefficient of 0.990 in diluted plasma. The specificity of the label-free immunosensor system was investigated using other steroid hormones, such as 17α, 20β-dihydroxy-4-pregnen-3-one, progesterone, estriol, estradiol, and testosterone. The specific detection of cortisol was suggested by a minimal change from -0.32 to 0.51 μA in the anodic peak value of the other steroid hormones. The sensor system was used to determine the plasma cortisol levels in Nile tilapia (Oreochromis niloticus), and the results were compared with those of the same samples determined using the conventional method (ELISA). A good correlation was obtained between values determined using both methods (correlation coefficient 0.993). These findings suggest that the proposed label-free immunosensor could be useful for rapid and convenient analysis of cortisol levels in fish plasma samples.

  1. [Determination of hydroxyproline in liver tissue by hydrophilic interaction chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry].

    PubMed

    Liu, Wei; Qi, Shenglan; Xu, Ying; Xiao, Zhun; Fu, Yadong; Chen, Jiamei; Yang, Tao; Liu, Ping

    2017-12-08

    A method for the determination of hydroxyproline (Hyp) in liver tissue of mice by hydrophilic interaction chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry (HILIC-HRMS) was developed. The liver tissue samples of normal mice and liver fibrosis mice induced by carbon tetrachloride were hydrolyzed by concentrated hydrochloric acid. After filtrated and diluted by solution, the diluent was separated on an Hypersil GOLD HILIC column (100 mm×2.1 mm, 3 μm). Water-acetonitrile (28:72, v/v)were used as the mobile phases with isocratic elution. Finally, the target analytes were detected in positive model by HRMS equipped with an electrospray ionization source. The linear range of hydroxyproline was from 0.78 to 100.00 μg/L with the correlation coefficient ( R 2 ) of 0.9983. The limit of quantification was 0.78 μg/L. By detecting the spiked samples, the recoveries were in the range of 97.4%-100.9% with the relative standard deviations (RSDs) between 1.4% and 2.0%. In addition, comparison of the measurement results by this method and the chloramine T method was proceeded. It was found that the linear correlation between the two methods was very good, and the Pearson correlation coefficient was 0.927. And this method had simpler operation procedure and higher accuracy than chloramine T method. This method can be used for the quick determination of hydroxyproline in liver tissue samples.

  2. [A correlation between respiration and synthesis of ATP in mitochondria at different degree of uncoupling of oxidative phosphorylation].

    PubMed

    Samartsev, V N; Kozhina, O V; Polishchuk, L S

    2005-01-01

    It is known that mitochondrial respiration in state 3 is due to three simultaneous and independent processes: synthesis of ATP (1), endogenous passive proton leakage (2), and proton leakage by protonophoric uncoupler (3). The total rate of processes (2) and (3) is equal to the product of respiration rate in state 4 and coefficient KR, which is defined as the ratio of the deltamuH+ value in state 3 to that in state 4. It is shown that it is possible to calculate both the rates of processes (1), (2) and (3) separately and the protonophoric activity of uncoupler using the coefficient KR and other coefficients, which are determined as the ratio of deltamuH+ values in state 3 or in state 4 to its maximal value. Simple methods of determination of these coefficients were developed, which are based on the study of the dependence of respiration rate in states 3 and 4 on the concentration of protonophoric uncoupler. It was found that the uncoupling action of palmitate, a natural uncoupler of oxidative phosphorylation, unlike classic uncoupler-protonophores DNP and FCCP, depends not only on its protonophoric activity but also on the inhibition of the process (1).

  3. Application of New Partition Coefficients to Modeling Plagioclase

    NASA Technical Reports Server (NTRS)

    Fagan, A. L.; Neal, C. R.; Rapp, J. F.; Draper, D. S.; Lapen, T. J.

    2017-01-01

    Previously, studies that determined the partition coefficient for an element, i, between plagioclase and the residual basaltic melt (Di plag) have been conducted using experimental conditions dissimilar from the Moon, and thus these values are not ideal for modeling plagioclase fractionation in a lunar system. However, recent work [1] has determined partition coefficients for plagioclase at lunar oxygen fugacities, and resulted in plagioclase with Anorthite contents =An90; these are significantly more calcic than plagioclase in previous studies, and the An content has a profound effect on partition coefficient values [2,3]. Plagioclase D-values, which are dependent on the An content of the crystal [e.g., 2-6], can be determined using published experimental data and the correlative An contents. Here, we examine new experimental data from [1] to ascertain their effect on the calculation of equilibrium liquids from Apollo 16 sample 60635,2. This sample is a coarse grained, subophitic impact melt composed of 55% plagioclase laths with An94.4-98.7 [7,8], distinctly more calcic than of previous partition coefficient studies (e.g., [3-6, 9-10]). Sample 60635,2 is notable as having several plagioclase trace element analyses containing a negative Europium anomaly (-Eu) in the rare-earth element (REE) profile, rather than the typical positive Eu anomaly (+Eu) [7-8] (Fig. 1). The expected +Eu is due to the similarity in size and charge with Ca2+, thereby allowing Eu2+ to be easily taken up by the plagioclase crystal structure, in contrast to the remaining REE3+. Some 60635,2 plagioclase crystals only have +Eu REE profiles, some only have -Eu REE profiles, and some +Eu and -Eu analyses in different areas on a single crystal [7, 8]. Moreover, there does not seem to be any core-rim association with the +Eu or -Eu analyses, nor does there appear to be a correlation between the size, shape, or location of a particular crystal within the sample and the sign of its Eu anomaly, which suggests a complex evolution. In order to investigate this sample further, we can calculate the equilibrium liquids, but with An contents distinct from previous experimental studies, we must calculate the appropriate partition coefficients for each trace element analysis.

  4. Observed intra-cluster correlation coefficients in a cluster survey sample of patient encounters in general practice in Australia

    PubMed Central

    Knox, Stephanie A; Chondros, Patty

    2004-01-01

    Background Cluster sample study designs are cost effective, however cluster samples violate the simple random sample assumption of independence of observations. Failure to account for the intra-cluster correlation of observations when sampling through clusters may lead to an under-powered study. Researchers therefore need estimates of intra-cluster correlation for a range of outcomes to calculate sample size. We report intra-cluster correlation coefficients observed within a large-scale cross-sectional study of general practice in Australia, where the general practitioner (GP) was the primary sampling unit and the patient encounter was the unit of inference. Methods Each year the Bettering the Evaluation and Care of Health (BEACH) study recruits a random sample of approximately 1,000 GPs across Australia. Each GP completes details of 100 consecutive patient encounters. Intra-cluster correlation coefficients were estimated for patient demographics, morbidity managed and treatments received. Intra-cluster correlation coefficients were estimated for descriptive outcomes and for associations between outcomes and predictors and were compared across two independent samples of GPs drawn three years apart. Results Between April 1999 and March 2000, a random sample of 1,047 Australian general practitioners recorded details of 104,700 patient encounters. Intra-cluster correlation coefficients for patient demographics ranged from 0.055 for patient sex to 0.451 for language spoken at home. Intra-cluster correlations for morbidity variables ranged from 0.005 for the management of eye problems to 0.059 for management of psychological problems. Intra-cluster correlation for the association between two variables was smaller than the descriptive intra-cluster correlation of each variable. When compared with the April 2002 to March 2003 sample (1,008 GPs) the estimated intra-cluster correlation coefficients were found to be consistent across samples. Conclusions The demonstrated precision and reliability of the estimated intra-cluster correlations indicate that these coefficients will be useful for calculating sample sizes in future general practice surveys that use the GP as the primary sampling unit. PMID:15613248

  5. Relationship between dental age according to Demirjian and cervical vertebrae maturity in Polish children.

    PubMed

    Różyło-Kalinowska, Ingrid; Kolasa--Rączka, Anna; Kalinowski, Paweł

    2011-02-01

    The purpose of the study was to investigate the relationship between Demirjian's method and the improved cervical vertebrae maturation (CVM) method. The material consisted of the clinical files and panoramic and lateral cephalometric radiographs of 718 children (431 girls and 287 boys) aged from 6 to 17 years, inhabitants of the Mazovia region (Central Poland). Dental age according to Demirjian was estimated using panoramic radiographs and the cervical stages (CS) of the CVM were evaluated on cephalometric radiographs. Descriptive statistics of the chronological and dental ages of the patients for a particular CS of skeletal maturity was calculated for girls and boys separately. Linear regression analysis and correlation (Pearson's r coefficient), as well as the Spearman rank correlation coefficient (R) were applied to measure the association between CS and dental calcification stages of all analysed teeth. A consistently earlier occurrence (by about 6 months) for each CS was observed in females. A moderate, but statistically significant, correlation between Demirjian's dental developmental stages and CS was determined. The level of the correlation was different for individual teeth: the teeth showing the highest relationship with CVM were the second premolars and canines (in female and male subjects, respectively). The central incisor demonstrated the poorest correlation in both genders. The findings confirmed that both dental and skeletal maturity should be assessed if the maturity stage of a growing child is to be relevant to clinical practice. The results indicate the usefulness of dental calcification stages as a simple first-level diagnostic test to determine the skeletal maturity status of a subject.

  6. Study of Left Ventricular Mass and Its Determinants on Echocardiography.

    PubMed

    Guleri, Namrata; Rana, Susheela; Chauhan, Randhir S; Negi, Prakash Chand; Diwan, Yogesh; Diwan, Deepa

    2017-09-01

    Increased Left Ventricular Mass (LVM) is an independent risk factor for cardiovascular morbidity and mortality. This study was done to find the prevalence and determinants of LVM in the Northern Indian population. A prospective cross-sectional observational study was carried out in a tertiary care centre in Himachal Pradesh, India and the study population included all consecutive patients fulfilling the inclusion criteria attending cardiology OPD on seeking medical attention with various symptoms for dyslipidaemia, hypertension but not on medication over a period of one year. Focused history was taken; physical examination and investigations were done. Data collected was analysed using Epi-info software version 3.5.1. We calculated means of LVM index for categorical variables i.e., sex, tobacco consumption, alcohol consumption and sedentary lifestyle etc., and also calculated p-values as test of significance for mean difference across the exposure variable groups. The Pearson correlation coefficient was calculated and 2 tailed significance at p< 0.05 was taken as statistically significant. Mean age of study population was 42.30±9.8 years and 62.9% were males. The mean LVM index was significantly higher in men than in women 77.7 ± 11.4 vs.71.3 ± 15.7 (p-value <0.01). Strong positive correlation was observed between increased waist hip ratio and increased Left Ventricular Mass Index (LVMI). The Pearson correlation coefficient was 36.77 and it was statistically significant with p-value 0.04. We found positive and independent correlation of increased LVMI with increased Waist Hip Ratio (WHR). A positive independent correlation was also observed with higher fasting blood sugar levels.

  7. Correlation between physical examination and three-dimensional gait analysis in the assessment of rotational abnormalities in children with cerebral palsy.

    PubMed

    Teixeira, Fernando Borge; Ramalho Júnior, Amancio; Morais Filho, Mauro César de; Speciali, Danielli Souza; Kawamura, Catia Miyuki; Lopes, José Augusto Fernandes; Blumetti, Francesco Camara

    2018-01-01

    Objective To evaluate the correlation between physical examination data concerning hip rotation and tibial torsion with transverse plane kinematics in children with cerebral palsy; and to determine which time points and events of the gait cycle present higher correlation with physical examination findings. Methods A total of 195 children with cerebral palsy seen at two gait laboratories from 2008 and 2016 were included in this study. Physical examination measurements included internal hip rotation, external hip rotation, mid-point hip rotation and the transmalleolar axis angle. Six kinematic parameters were selected for each segment to assess hip rotation and shank-based foot rotation. Correlations between physical examination and kinematic measures were analyzed by Spearman correlation coefficients, and a significance level of 5% was considered. Results Comparing physical examination measurements of hip rotation and hip kinematics, we found moderate to strong correlations for all variables (p<0.001). The highest coefficients were seen between the mid-point hip rotation on physical examination and hip rotation kinematics (rho range: 0.48-0.61). Moderate correlations were also found between the transmalleolar axis angle measurement on physical examination and foot rotation kinematics (rho range 0.44-0.56; p<0.001). Conclusion These findings may have clinical implications in the assessment and management of transverse plane gait deviations in children with cerebral palsy.

  8. Detection of moisture and moisture related phenomena from Skylab. [correlation of brightness and antenna temperature with soil moisture for Texas and Kansas test sites

    NASA Technical Reports Server (NTRS)

    Eagleman, J. R.; Pogge, E. C.; Moore, R. K. (Principal Investigator); Hardy, N.; Lin, W.; League, L.

    1974-01-01

    The author has identified the following significant results. Skylab 2 data for June 5, 1973 (Texas site) relates favorably with previously calculated aircraft data when correlating brightness temperature to soil moisture. However, more detailed work is needed to determine the corrected surface temperature. In addition, correlations between the S194 antenna temperature and soil moisture have been obtained for five sets of Skylab data. The best correlations were obtained for the surface to one inch depth in four cases and for surface to two inches depth for the fifth case. Correlation coefficients for the surface to one inch depth were -0.98, -0.95, -0.90, -0.82, and -0.80.

  9. Selling blood and gametes during tough economic times: insights from Google search.

    PubMed

    Wu, Jonathan A; Ngo, Tin C; Rothman, Cappy; Breyer, Benjamin N; Eisenberg, Michael L

    2015-10-01

    To use Google Insights search volume and publicly available economic indicators to test the hypothesis that sperm, egg, and blood donations increase during economic downturns and to demonstrate the feasibility of using Google search volume data to predict national trends in actual sperm, egg, and blood donations rates. Cross-correlation statistical analysis comparing Google search data for terms relating to blood, egg, and sperm donations with various economic indicators including the S&P 500 closing values, gross domestic product (GDP), the U.S. Index of Leading Indicators (U.S. Leading Index), gross savings rate, mortgage interest rates, unemployment rate, and consumer price index (CPI) from 2004-2011. A secondary analysis determined the Pearson correlation coefficient between Google search data with actual sperm, egg, and blood donation volume in the U.S. as measured by California Cryobank, the National Assisted Reproductive Technology Surveillance System, and the National Blood Collection and Utilization Survey, respectively. Significance of cross-correlation and Pearson correlation analysis as indicated by p value. There were several highly significant cross-correlation relationships between search volume and various economic indicators. Correlation between Google search volume for the term 'sperm donation,' 'egg donation,' and 'blood donation' with actual number of sperm, egg and blood donations in the United States demonstrated Pearson correlation coefficients of 0.2 (p > 0.10), -0.1 (p > 0.10), and 0.07 (p > 0.10), respectively. Temporal analysis showed an improved correlation coefficient of 0.9 (p < 0.05) for blood donation when shifted 12 months later relative to Google search volume. Google search volume data for search terms relating to sperm, egg, and blood donation increase during economic downturns. This finding suggests gamete and bodily fluid donations are influenced by market forces like other commodities. Google search may be useful for predicting blood donation trends but is more limited in predicting actual semen and oocyte donation patterns.

  10. Spatial and temporal variation of correlation between the Arctic total ozone and atmospheric temperature

    NASA Astrophysics Data System (ADS)

    Huang, Fuxiang; Ren, suling; Han, Shuangshuang; Zheng, xiangdong; Deng, xuejiao

    2017-04-01

    Daily total ozone and atmospheric temperature profile data in 2015 from the AIRS are used to investigate the spatial and temporal variation of the correlation between the Arctic atmospheric ozone and temperature. In the study, 11 lays atmospheric temperature profiles from the troposphere to the stratosphere are investigated. These layer heights are 20, 50, 70, 100, 200, 250, 300, 400, 500, 600 and 700 hPa respectively. The results show that a significant seasonal split exists in the correlation between the Arctic ozone and atmospheric temperature. Figure 1 shows the spatial and temporal variation of the coefficient between the atmospheric ozone and temperature at 50hPa. It can be seen from the figure that an obvious spatiotemporal difference exists in the correlation between the Arctic total ozone and atmospheric temperature in the lower stratosphere. First, the seasonal difference is very remarkable, which is shown as a significant positive correlation in most regions during winter and summer, while no correlation in the majority of regions occurs during spring and autumn, with a weak positive or negative correlation in a small number regions. Second, the spatial differences are also very obvious. The summer maximum correlation coefficient occurs in the Barents Sea and other locations at 0.8 and above, while the winter maximum occurs in the Baffin Bay area at 0.6 to 0.8. However, in a small number of regions, such as the land to the west of the Bering Strait in winter and the Arctic Ocean core area in summer, the correlation coefficients were unable to pass the significance test to show no correlation. At the same time, in spring and autumn, a positive correlation only occurs over a few low-latitude land areas, while over other Arctic areas, weak negative correlation exists. The differences in horizontal position are clearly related to the land-sea distribution, underlying surface characteristics, glacial melting, and other factors. In the troposphere, the ozone and temperature have a strong negative correlation in spring and autumn, while presenting a weak negative correlation or no correlation in winter and summer. Figure 2 shows the spatial and temporal variation of the correlation coefficient between the atmospheric ozone and temperature at 500hPa. From figure 2, it can be seen that in the Arctic troposphere, the atmospheric ozone and tropospheric temperature mainly have a negative correlation. In winter and summer, a weak negative correlation is shown overall, but more than a third of the regions show no correlation. In spring, the negative correlation is the strongest between the ozone and temperature. Especially in Greenland - Queen Elizabeth Islands and southern New Siberian Islands, the correlation is the highest, with a correlation coefficient of -0.9 and above, followed by a negative correlation in autumn. Except for a small number of low-latitude scattered regions with weak correlation, the correlation coefficients of most regions are ranged between -0.5 and -0.7. At 300 hPa near the tropopause, the horizontal distribution and seasonal change of the correlation between the Arctic total ozone and atmospheric temperature are as shown in Fig. 3.At the height near the Arctic tropopause, the atmospheric ozone mainly has no correlation to temperature, especially in winter and summer, when no correlation exists in the majority of regions, while weak positive or negative correlation occurs in a small number of areas. In the majority of regions during spring, a weak negative correlation is shown, while no correlation appears in Western Greenland - Queen Elizabeth Islands. In autumn, most regions show no correlation, while weak negative correlation is presented in Eastern Greenland, Norwegian Sea - Barents Sea, and other locations. From figure 1-3, we can see a significant difference exists from the common law of positive correlation in the lower stratosphere and negative correlation in the troposphere at mid-low latitudes. The Arctic atmospheric ozone has a relation with temperature, showing significant spatial and temporal variation characteristics. In the stratosphere, winter and summer atmospheric temperatures mainly have a positive correlation to ozone. The summer maximum occurs in the Barents Sea to achieve 0.8 and above, while the winter maximum is 0.6 to 0.8 in the Baffin Bay area. In the troposphere, the autumn and spring atmospheric temperatures mainly have a negative correlation to the ozone. The spring correlation coefficient in Greenland to the Queen Elizabeth Islands reaches up to -0.9 and above, while the autumn value is -0.5 to -0.7. At about 300 hPa, the tropopause value is reduced to 0, and further decreased in the troposphere, to show a strong negative correlation. Based on the comprehensive analysis of various influence factors, the possible action mechanism of the spatiotemporal variation pattern of the correlation between the Arctic atmospheric ozone and temperature is discussed based on the seasonal differences of various influence factors. The spatial and temporal variation characteristics of the correlation between the Arctic atmospheric ozone and temperature are determined by the seasonal variation of various influencing factors of the Arctic atmospheric ozone and temperature. These factors include the atmospheric heating effect from the ozone matching with the Arctic sunshine conditions, the influence of dynamic delivery on the ozone and heat, the impact of underlying-surface glacial melting on atmospheric radiation and heat budget, and so on. At different heights in each season, the different effects from all kinds of factors on the ozone and temperature determine the spatiotemporal variation of the correlation between the ozone and temperature.

  11. Feature Genes Selection Using Supervised Locally Linear Embedding and Correlation Coefficient for Microarray Classification

    PubMed Central

    Wang, Yun; Huang, Fangzhou

    2018-01-01

    The selection of feature genes with high recognition ability from the gene expression profiles has gained great significance in biology. However, most of the existing methods have a high time complexity and poor classification performance. Motivated by this, an effective feature selection method, called supervised locally linear embedding and Spearman's rank correlation coefficient (SLLE-SC2), is proposed which is based on the concept of locally linear embedding and correlation coefficient algorithms. Supervised locally linear embedding takes into account class label information and improves the classification performance. Furthermore, Spearman's rank correlation coefficient is used to remove the coexpression genes. The experiment results obtained on four public tumor microarray datasets illustrate that our method is valid and feasible. PMID:29666661

  12. Feature Genes Selection Using Supervised Locally Linear Embedding and Correlation Coefficient for Microarray Classification.

    PubMed

    Xu, Jiucheng; Mu, Huiyu; Wang, Yun; Huang, Fangzhou

    2018-01-01

    The selection of feature genes with high recognition ability from the gene expression profiles has gained great significance in biology. However, most of the existing methods have a high time complexity and poor classification performance. Motivated by this, an effective feature selection method, called supervised locally linear embedding and Spearman's rank correlation coefficient (SLLE-SC 2 ), is proposed which is based on the concept of locally linear embedding and correlation coefficient algorithms. Supervised locally linear embedding takes into account class label information and improves the classification performance. Furthermore, Spearman's rank correlation coefficient is used to remove the coexpression genes. The experiment results obtained on four public tumor microarray datasets illustrate that our method is valid and feasible.

  13. Reliability and validity of the French-Canadian version of the scoliosis research society 22 questionnaire in France.

    PubMed

    Lonjon, Guillaume; Ilharreborde, Brice; Odent, Thierry; Moreau, Sébastien; Glorion, Christophe; Mazda, Keyvan

    2014-01-01

    Outcome study to determine the internal consistency, reproducibility, and concurrent validity of the French-Canadian version of the Scoliosis Research Society 22 (SRS-22 fcv) patient questionnaire in France. To determine whether the SRS-22 fcv can be used in a population from France. The SRS-22 has been translated and validated in multiple countries, notably in the French-Canadian language in Quebec, Canada. Use of SRS-22 fcv seems appropriate for evaluating adolescent idiopathic scoliosis in France. However, French-Canadian French is noticeably different from the French spoken in France, and no study has investigated the use of a French-Canadian version of a health-quality questionnaire in another French population. The methods used for validating the SRS-22 fcv in Quebec were adopted for use with a group of 200 adolescents with idiopathic scoliosis and 60 healthy adolescents in France. Reliability and reproducibility were measured by the Cronbach α and intraclass correlation coefficient (ICC), construct validity by factorial analysis, concurrent validity by the Short-Form of the survey, and discriminant validity by analysis of variance and multivariate linear regression. In France, the SRS-22 fcv showed good global internal consistency (Cronbach α = 0.87, intraclass correlation coefficient = 0.92), a coherent factorial structure, and high correlation coefficients between the SRS-22 fcv and Short-Form of the survey (P < 0.001). However, reliability and validity were slightly less than that for the instrument's original validation and the validation of the SRS-22 fcv in Quebec. These differences could be explained by language and cultural differences. The SRS-22 fcv is relevant for use in France, but further development and validation of a specific French questionnaire remain necessary to improve the assessment of functional outcomes of adolescents with scoliosis in France. N/A.

  14. Validation of a simplified food frequency questionnaire for the assessment of dietary habits in Iranian adults: Isfahan Healthy Heart Program, Iran.

    PubMed

    Mohammadifard, Noushin; Sajjadi, Firouzeh; Maghroun, Maryam; Alikhasi, Hassan; Nilforoushzadeh, Farzaneh; Sarrafzadegan, Nizal

    2015-03-01

    Dietary assessment is the first step of dietary modification in community-based interventional programs. This study was performed to validate a simple food frequency questionnaire (SFFQ) for assessment of selected food items in epidemiological studies with a large sample size as well as community trails. This validation study was carried out on 264 healthy adults aged ≥ 41 years old living in 3 district central of Iran, including Isfahan, Najafabad, and Arak. Selected food intakes were assessed using a 48-item food frequency questionnaire (FFQ). The FFQ was interviewer-administered, which was completed twice; at the beginning of the study and 2 weeks thereafter. The validity of this SFFQ was examined compared to estimated amount by single 24 h dietary recall and 2 days dietary record. Validation of the FFQ was determined using Spearman correlation coefficients between daily frequency consumption of food groups as assessed by the FFQ and the qualitative amount of daily food groups intake accessed by dietary reference method was applied to evaluate validity. Intraclass correlation coefficients (ICC) were used to determine the reproducibility. Spearman correlation coefficient between the estimated amount of food groups intake by examined and reference methods ranged from 0.105 (P = 0.378) in pickles to 0.48 (P < 0.001) in plant protein. ICC for reproducibility of FFQ were between 0.47-0.69 in different food groups (P < 0.001). The designed SFFQ has a good relative validity and reproducibility for assessment of selected food groups intake. Thus, it can serve as a valid tool in epidemiological studies and clinical trial with large participants.

  15. Determining the K coefficient to leaf area index estimations in a tropical dry forest

    NASA Astrophysics Data System (ADS)

    Magalhães, Sarah Freitas; Calvo-Rodriguez, Sofia; do Espírito Santo, Mário Marcos; Sánchez Azofeifa, Gerardo Arturo

    2018-03-01

    Vegetation indices are useful tools to remotely estimate several important parameters related to ecosystem functioning. However, improving and validating estimations for a wide range of vegetation types are necessary. In this study, we provide a methodology for the estimation of the leaf area index (LAI) in a tropical dry forest (TDF) using the light diffusion through the canopy as a function of the successional stage. For this purpose, we estimated the K coefficient, a parameter that relates the normalized difference vegetation index (NDVI) to LAI, based on photosynthetically active radiation (PAR) and solar radiation. The study was conducted in the Mata Seca State Park, in southeastern Brazil, from 2012 to 2013. We defined four successional stages (very early, early, intermediate, and late) and established one optical phenology tower at one plot of 20 × 20 m per stage. Towers measured the incoming and reflected solar radiation and PAR for NDVI calculation. For each plot, we established 24 points for LAI sampling through hemispherical photographs. Because leaf cover is highly seasonal in TDFs, we determined ΔK (leaf growth phase) and K max (leaf maturity phase). We detected a strong correlation between NDVI and LAI, which is necessary for a reliable determination of the K coefficient. Both NDVI and LAI varied significantly between successional stages, indicating sensitivity to structural changes in forest regeneration. Furthermore, the K values differed between successional stages and correlated significantly with other environmental variables such as air temperature and humidity, fraction of absorbed PAR, and soil moisture. Thus, we established a model based on spectral properties of the vegetation coupled with biophysical characteristics in a TDF that makes possible to estimate LAI from NDVI values. The application of the K coefficient can improve remote estimations of forest primary productivity and gases and energy exchanges between vegetation and atmosphere. This model can be applied to distinguish different successional stages of TDFs, supporting environmental monitoring and conservation policies towards this biome.

  16. Pearson's Correlation between Three Variables; Using Students' Basic Knowledge of Geometry for an Exercise in Mathematical Statistics

    ERIC Educational Resources Information Center

    Vos, Pauline

    2009-01-01

    When studying correlations, how do the three bivariate correlation coefficients between three variables relate? After transforming Pearson's correlation coefficient r into a Euclidean distance, undergraduate students can tackle this problem using their secondary school knowledge of geometry (Pythagoras' theorem and similarity of triangles).…

  17. Correlations between commonly used clinical outcome scales and patient satisfaction after total knee arthroplasty.

    PubMed

    Kwon, Sae Kwang; Kang, Yeon Gwi; Kim, Sung Ju; Chang, Chong Bum; Seong, Sang Cheol; Kim, Tae Kyun

    2010-10-01

    Patient satisfaction is becoming increasingly important as a crucial outcome measure for total knee arthroplasty. We aimed to determine how well commonly used clinical outcome scales correlate with patient satisfaction after total knee arthroplasty. In particular, we sought to determine whether patient satisfaction correlates better with absolute postoperative scores or preoperative to 12-month postoperative changes. Patient satisfaction was evaluated using 4 grades (enthusiastic, satisfied, noncommittal, and disappointed) for 438 replaced knees that were followed for longer than 1 year. Outcomes scales used the American Knee Society, Western Ontario McMaster University Osteoarthritis Index scales, and Short Form-36 scores. Correlation analyses were performed to investigate the relation between patient satisfaction and the 2 different aspects of the outcome scales: postoperative scores evaluated at latest follow-ups and preoperative to postoperative changes. The Western Ontario McMaster University Osteoarthritis Index scales function score was most strongly correlated with satisfaction (correlation coefficient=0.45). Absolute postoperative scores were better correlated with satisfaction than the preoperative to postoperative changes for all scales. Level IV (retrospective case series). Copyright © 2010 Elsevier Inc. All rights reserved.

  18. Statistical hypothesis tests of some micrometeorological observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SethuRaman, S.; Tichler, J.

    Chi-square goodness-of-fit is used to test the hypothesis that the medium scale of turbulence in the atmospheric surface layer is normally distributed. Coefficients of skewness and excess are computed from the data. If the data are not normal, these coefficients are used in Edgeworth's asymptotic expansion of Gram-Charlier series to determine an altrnate probability density function. The observed data are then compared with the modified probability densities and the new chi-square values computed.Seventy percent of the data analyzed was either normal or approximatley normal. The coefficient of skewness g/sub 1/ has a good correlation with the chi-square values. Events withmore » vertical-barg/sub 1/vertical-bar<0.21 were normal to begin with and those with 0.21« less

  19. Effect of Strain, Region, and Tissue Composition on Glucose Partitioning in Meniscus Fibrocartilage.

    PubMed

    Kleinhans, Kelsey L; Jackson, Alicia R

    2017-03-01

    A nearly avascular tissue, the knee meniscus relies on diffusive transport for nutritional supply to cells. Nutrient transport depends on solute partitioning in the tissue, which governs the amount of nutrients that can enter a tissue. The purpose of the present study was to investigate the effects of mechanical strain, tissue region, and tissue composition on the partition coefficient of glucose in meniscus fibrocartilage. A simple partitioning experiment was employed to measure glucose partitioning in porcine meniscus tissues from two regions (horn and central), from both meniscal components (medial and lateral), and at three levels of compression (0%, 10%, and 20%). Partition coefficient values were correlated to strain level, water volume fraction, and glycosaminoglycan (GAG) content of tissue specimens. Partition coefficient values ranged from 0.47 to 0.91 (n = 48). Results show that glucose partition coefficient is significantly (p < 0.001) affected by compression, decreasing with increasing strain. Furthermore, we did not find a statistically significant effect of tissue when comparing medial versus lateral (p = 0.181) or when comparing central and horn regions (p = 0.837). There were significant positive correlations between tissue water volume fraction and glucose partitioning for all groups. However, the correlation between GAG content and partitioning was only significant in the lateral horn group. Determining how glucose partitioning is affected by tissue composition and loading is necessary for understanding nutrient availability and related tissue health and/or degeneration. Therefore, this study is important for better understanding the transport and nutrition-related mechanisms of meniscal degeneration.

  20. Relationship between Agronomic Parameters, Phenolic Composition of Grape Skin, and Texture Properties of Vitis vinifera L. cv. Tempranillo.

    PubMed

    García-Estévez, Ignacio; Andrés-García, Paula; Alcalde-Eon, Cristina; Giacosa, Simone; Rolle, Luca; Rivas-Gonzalo, Julián C; Quijada-Morín, Natalia; Escribano-Bailón, M Teresa

    2015-09-09

    The relationship between the agronomic parameters of grapevine and the phenolic composition of skin of Vitis vinifera L. cv. Tempranillo grapes was assessed. The physical and mechanical properties of berries and their skins were also determined and correlated to the chemical composition. Results showed a significant negative correlation between grapevine vigor-related parameters (such as leaf area and bunch weight) and anthocyanin composition, whereas the percentage (w/w) of seeds was negatively correlated with the amount of flavanols of grape skins. Texture properties of grape skins also showed an important relationship with chemical composition. Berry hardness showed a negative correlation with the coumaroyl-anthocyanin derivatives, but it was positively correlated to skin flavanic composition. Moreover, significant regressions with high coefficients of determination were found between phenolic composition and grapevine vigor-related and texture variables, thus pointing out that these parameters might be useful for estimating the phenolic composition of grape skins.

  1. Research of rotating machinery vibration parameters - Shaft speed relationship

    NASA Astrophysics Data System (ADS)

    Kostyukov, V. N.; Kostyukov, A. V.; Zaytsev, A. V.; Teterin, A. O.

    2017-08-01

    The paper considers the relationship between the parameters of the vibration arising in rotating machinery during operation and the shaft speed. The goal of this paper is to determine the dependence of the vibration parameters on the shaft speed for solving applied engineering problems. To properly evaluate the technical condition of bearing assemblies, we should take into account the pattern of the rotating machinery vibration parameters-shaft speed relationship, which will allow creating new diagnostic features, the totality of which will ensure an increased reliability of diagnosis. We took the check for a correlation between the factor and resultative feature parameters as the correlation analysis method. A high pair linear correlation between the diagnostic features (acceleration, velocity, displacement) and the shaft speed was determined on the basis of the check for correlation between the vibration parameters and the shaft speed, and also the linear correlation coefficients can be used to solve the applied engineering problems of diagnosing the bearing assemblies of the rotating machinery.

  2. Surface area and volume determination of subgingival calculus using laser fluorescence.

    PubMed

    Shakibaie, Fardad; Walsh, Laurence J

    2014-03-01

    Visible red (655 nm) laser fluorescence (LF) devices are currently used for identifying deposits of subgingival calculus on the root surfaces of teeth during dental examination and treatment; however, it is not known how the fluorescence readings produced by commercially available LF systems correlate to the nature of the deposits. This laboratory study explored the correlation between LF digital readings and the surface area and volume of subgingival calculus deposits on teeth. A collection of 30 extracted human posterior teeth with various levels of subgingival deposits of calculus across 240 sites were used in a clinical simulation, with silicone impression material used to replicate periodontal soft tissues. The teeth were scored by two examiners by using three commercial LF systems (DIAGNOdent, DIAGNOdent Pen and KEY3). The silicone was removed, and the teeth were removed for photography at × 20 magnification under white or ultraviolet light. The surface area, thickness, and volume were calculated, and both linear least squares regression and nonlinear (Spearman's rank method) correlation coefficients were determined. Visible red LF digital readings showed better correlation to calculus volume than to surface area. Overall, the best performance was found for the KEY3 system (Spearman coefficient 0.59), compared to the Classic DIAGNOdent (0.56) and the DIAGNOdent Pen (0.49). These results indicate that while visible red LF systems vary somewhat in performance, their LF readings provide a useful estimation of the volume of subgingival calculus deposits present on teeth.

  3. Dynamic gadolinium-enhanced magnetic resonance imaging allows accurate assessment of the synovial inflammatory activity in rheumatoid arthritis knee joints: a comparison with synovial histology.

    PubMed

    Axelsen, M B; Stoltenberg, M; Poggenborg, R P; Kubassova, O; Boesen, M; Bliddal, H; Hørslev-Petersen, K; Hanson, L G; Østergaard, M

    2012-03-01

    To determine whether dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) evaluated using semi-automatic image processing software can accurately assess synovial inflammation in rheumatoid arthritis (RA) knee joints. In 17 RA patients undergoing knee surgery, the average grade of histological synovial inflammation was determined from four biopsies obtained during surgery. A preoperative series of T(1)-weighted dynamic fast low-angle shot (FLASH) MR images was obtained. Parameters characterizing contrast uptake dynamics, including the initial rate of enhancement (IRE), were generated by the software in three different areas: (I) the entire slice (Whole slice); (II) a manually outlined region of interest (ROI) drawn quickly around the joint, omitting large artefacts such as blood vessels (Quick ROI); and (III) a manually outlined ROI following the synovial capsule of the knee joint (Precise ROI). Intra- and inter-reader agreement was assessed using the intra-class correlation coefficient (ICC). The IRE from the Quick ROI and the Precise ROI revealed high correlations to the grade of histological inflammation (Spearman's correlation coefficient (rho) = 0.70, p = 0.001 and rho = 0.74, p = 0.001, respectively). Intra- and inter-reader ICCs were very high (0.93-1.00). No Whole slice parameters were correlated to histology. DCE-MRI provides fast and accurate assessment of synovial inflammation in RA patients. Manual outlining of the joint to omit large artefacts is necessary.

  4. The correlation between preoperative volumetry and real graft weight: comparison of two volumetry programs.

    PubMed

    Mussin, Nadiar; Sumo, Marco; Lee, Kwang-Woong; Choi, YoungRok; Choi, Jin Yong; Ahn, Sung-Woo; Yoon, Kyung Chul; Kim, Hyo-Sin; Hong, Suk Kyun; Yi, Nam-Joon; Suh, Kyung-Suk

    2017-04-01

    Liver volumetry is a vital component in living donor liver transplantation to determine an adequate graft volume that meets the metabolic demands of the recipient and at the same time ensures donor safety. Most institutions use preoperative contrast-enhanced CT image-based software programs to estimate graft volume. The objective of this study was to evaluate the accuracy of 2 liver volumetry programs (Rapidia vs . Dr. Liver) in preoperative right liver graft estimation compared with real graft weight. Data from 215 consecutive right lobe living donors between October 2013 and August 2015 were retrospectively reviewed. One hundred seven patients were enrolled in Rapidia group and 108 patients were included in the Dr. Liver group. Estimated graft volumes generated by both software programs were compared with real graft weight measured during surgery, and further classified into minimal difference (≤15%) and big difference (>15%). Correlation coefficients and degree of difference were determined. Linear regressions were calculated and results depicted as scatterplots. Minimal difference was observed in 69.4% of cases from Dr. Liver group and big difference was seen in 44.9% of cases from Rapidia group (P = 0.035). Linear regression analysis showed positive correlation in both groups (P < 0.01). However, the correlation coefficient was better for the Dr. Liver group (R 2 = 0.719), than for the Rapidia group (R 2 = 0.688). Dr. Liver can accurately predict right liver graft size better and faster than Rapidia, and can facilitate preoperative planning in living donor liver transplantation.

  5. Validation of an analytical method for the quantitative determination of selenium in bacterial biomass by ultraviolet-visible spectrophotometry.

    PubMed

    Mörschbächer, Ana Paula; Dullius, Anja; Dullius, Carlos Henrique; Bandt, Cassiano Ricardo; Kuhn, Daniel; Brietzke, Débora Tairini; Malmann Kuffel, Fernando José; Etgeton, Henrique Pretto; Altmayer, Taciélen; Gonçalves, Tamara Engelmann; Oreste, Eliézer Quadro; Ribeiro, Anderson Schwingel; de Souza, Claucia Fernanda Volken; Hoehne, Lucélia

    2018-07-30

    The present paper describes the validation of a spectrophotometry method involving molecular absorption in the visible ultraviolet-visible (UV-Vis) region for selenium (Se) determination in the bacterial biomass produced by lactic acid bacteria (LAB). The method was found to be suitable for the target application and presented a linearity range from 0.025 to 0.250 mg/L Se. The angular and linear coefficients of the linear equation were 1.0678 and 0.0197 mg/L Se, respectively, and the linear correlation coefficient (R 2 ) was 0.9991. Analyte recovery exceeded 96% with a relative standard deviation (RSD) below 3%. The Se contents in LAB ranged from 0.01 to 20 mg/g. The Se contents in the bacterial biomass determined by UV-Vis were not significantly different (p > 0.05) those determined by graphite furnace atomic absorption spectrometry. Thus, Se can be quantified in LAB biomass using this relatively simpler technique. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Two-Way Gene Interaction From Microarray Data Based on Correlation Methods.

    PubMed

    Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh

    2016-06-01

    Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman's rank correlation coefficient and Blomqvist's measure, and compared them with Pearson's correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson's correlation, Spearman's rank correlation, and Blomqvist's coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist's coefficient was not confirmed by visual methods. Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data.

  7. Correlation between standardized uptake value and apparent diffusion coefficient of neoplastic lesions evaluated with whole-body simultaneous hybrid PET/MRI.

    PubMed

    Rakheja, Rajan; Chandarana, Hersh; DeMello, Linda; Jackson, Kimberly; Geppert, Christian; Faul, David; Glielmi, Christopher; Friedman, Kent P

    2013-11-01

    The purpose of this study was to assess the correlation between standardized uptake value (SUV) and apparent diffusion coefficient (ADC) of neoplastic lesions in the use of a simultaneous PET/MRI hybrid system. Twenty-four patients with known primary malignancies underwent FDG PET/CT. They then underwent whole-body PET/MRI. Diffusion-weighted imaging was performed with free breathing and a single-shot spin-echo echo-planar imaging sequence with b values of 0, 350, and 750 s/mm(2). Regions of interest were manually drawn along the contours of neoplastic lesions larger than 1 cm, which were clearly identified on PET and diffusion-weighted images. Maximum SUV (SUVmax) on PET/MRI and PET/CT images, mean SUV (SUVmean), minimum ADC (ADCmin), and mean ADC (ADCmean) were recorded on PET/MR images for each FDG-avid neoplastic soft-tissue lesion with a maximum of three lesions per patient. Pearson correlation coefficient was used to asses the following relations: SUVmax versus ADCmin on PET/MR and PET/CT images, SUVmean versus ADCmean, and ratio of SUVmax to mean liver SUV (SUV ratio) versus ADCmin. A subanalysis of patients with progressive disease versus partial treatment response was performed with the ratio of SUVmax to ADCmin for the most metabolically active lesion. Sixty-nine neoplastic lesions (52 nonosseous lesions, 17 bone metastatic lesions) were evaluated. The mean SUVmax from PET/MRI was 7.0 ± 6.0; SUVmean, 5.6 ± 4.6; mean ADCmin, 1.10 ± 0.58; and mean ADCmean, 1.48 ± 0.72. A significant inverse Pearson correlation coefficient was found between PET/MRI SUVmax and ADCmin (r = -0.21, p = 0.04), between SUVmean and ADCmean (r = -0.18, p = 0.07), and between SUV ratio and ADCmin (r = -0.27, p = 0.01). A similar inverse Pearson correlation coefficient was found between the PET/CT SUVmax and ADCmin. Twenty of 24 patients had previously undergone PET/CT; five patients had a partial treatment response, and six had progressive disease according to Response Evaluation Criteria in Solid Tumors 1.1. The ratio between SUVmax and ADCmin was higher among patients with progressive disease than those with a partial treatment response. Simultaneous PET/MRI is a promising technology for the detection of neoplastic disease. There are inverse correlations between SUVmax and ADCmin and between SUV ratio and ADCmin. Correlation coefficients between SUVmax and ADCmin from PET/MRI were similar to values obtained with SUVmax from the same-day PET/CT. Given that both SUV and ADC are related to malignancy and that the correlation between the two biomarkers is relatively weak, SUV and ADC values may offer complementary information to aid in determination of prognosis and treatment response. The combined tumoral biomarker, ratio between SUVmax and ADCmin, may be useful for assessing progressive disease versus partial treatment response.

  8. Drag and stability characteristics of a variety of reefed and unreefed parachute configurations at Mach 1.80 with an empirical correlation for supersonic Mach numbers

    NASA Technical Reports Server (NTRS)

    Couch, L. M.

    1975-01-01

    An investigation was conducted at Mach 1.80 in the Langley 4-foot supersonic pressure tunnel to determine the effects of variation in reefing ratio and geometric porosity on the drag and stability characteristics of four basic canopy types deployed in the wake of a cone-cylinder forebody. The basic designs included cross, hemisflo, disk-gap-band, and extended-skirt canopies; however, modular cross and standard flat canopies and a ballute were also investigated. An empirical correlation was determined which provides a fair estimation of the drag coefficients in transonic and supersonic flow for parachutes of specified geometric porosity and reefing ratio.

  9. Cadence, age, and weight as determinants of forefoot plantar pressures using the Biofoot in-shoe system.

    PubMed

    Martínez-Nova, Alfonso; Pascual Huerta, Javier; Sánchez-Rodríguez, Raquel

    2008-01-01

    We evaluated normal plantar pressures and studied the effect of weight, cadence, and age on forefoot plantar pressures in healthy subjects by using the Biofoot (Instituto de Biomecánica de Valencia, Valencia, Spain) in-shoe measurement system. The feet of 45 healthy subjects with no evident foot or lower-limb diseases were measured with the Biofoot in-shoe system. The forefoot was divided into seven areas: the first through fifth metatarsal heads, the hallux, and the second through fifth lesser toes. Three trials of 8 sec each were recorded twice in each subject, and the mean was used to analyze peak and mean plantar pressures. A multiple regression model including weight, age, and cadence was run for each metatarsal head, the hallux, and the lesser toes. Intraclass correlation coefficients and coefficients of variation were also calculated to assess reliability. The second metatarsal head had the greatest peak (960 kPa) and mean (585.1 kPa) pressures, followed by the third metatarsal head. Weight and cadence combined explained 18% and 23% of peak plantar pressure at the second and third metatarsal heads, respectively (P < .001). The intraclass correlation coefficient varied from 0.76 to 0.96 for all variables. The coefficient of variation between sessions ranged from 5.8% to 9.0%. The highest peak and mean plantar pressures were found at the second and third metatarsal heads in healthy subjects. Weight, cadence, and age explained a low variability of this pressure pattern. The Biofoot in-shoe system has good reliability to measure plantar pressures. These data will have implications for the understanding of normal foot biomechanics and its determinants.

  10. Genotypic gain with simultaneous selection of production, nutrition, and culinary traits in cowpea crosses and backcrosses using mixed models.

    PubMed

    Oliveira, D G; Rocha, M M; Damasceno-Silva, K J; Sá, F V; Lima, L R L; Resende, M D V

    2017-08-17

    The aim of this study was to estimate the genotypic gain with simultaneous selection of production, nutrition, and culinary traits in cowpea crosses and backcrosses and to compare different selection indexes. Eleven cowpea populations were evaluated in a randomized complete block design with four replications. Fourteen traits were evaluated, and the following parameters were estimated: genotypic variation coefficient, genotypic determination coefficient, experimental quality indicator and selection reliability, estimated genotypic values ​​- BLUE, genotypic correlation coefficient among traits, and genotypic gain with simultaneous selection of all traits. The genotypic gain was estimated based on tree selection indexes: classical, multiplicative, and the sum of ranks. The genotypic variation coefficient was higher than the environmental variation coefficient for the number of days to start flowering, plant type, the weight of one hundred grains, grain index, and protein concentration. The majority of the traits presented genotypic determination coefficient from medium to high magnitude. The identification of increases in the production components is associated with decreases in protein concentration, and the increase in precocity leads to decreases in protein concentration and cooking time. The index based on the sum of ranks was the best alternative for simultaneous selection of traits in the cowpea segregating populations resulting from the crosses and backcrosses evaluated, with emphasis on the F 4 BC 12 , F 4 C 21 , and F 4 C 12 populations, which had the highest genotypic gains.

  11. Fundamental mass transfer modeling of emission of volatile organic compounds from building materials

    NASA Astrophysics Data System (ADS)

    Bodalal, Awad Saad

    In this study, a mass transfer theory based model is presented for characterizing the VOC emissions from building materials. A 3-D diffusion model is developed to describe the emissions of volatile organic compounds (VOCs) from individual sources. Then the formulation is extended to include the emissions from composite sources (system comprising an assemblage of individual sources). The key parameters for the model (The diffusion coefficient of the VOC in the source material D, and the equilibrium partition coefficient k e) were determined independently (model parameters are determined without the use of chamber emission data). This procedure eliminated to a large extent the need for emission testing using environmental chambers, which is costly, time consuming, and may be subject to confounding sink effects. An experimental method is developed and implemented to measure directly the internal diffusion (D) and partition coefficients ( ke). The use of the method is illustrated for three types of VOC's: (i) Aliphatic Hydrocarbons, (ii) Aromatic Hydrocarbons and ( iii) Aldehydes, through typical dry building materials (carpet, plywood, particleboard, vinyl floor tile, gypsum board, sub-floor tile and OSB). Then correlations for predicting D and ke based solely on commonly available properties such as molecular weight and vapour pressure were proposed for each product and type of VOC. These correlations can be used to estimate the D and ke when direct measurement data are not available, and thus facilitate the prediction of VOC emissions from the building materials using mass transfer theory. The VOC emissions from a sub-floor material (made of the recycled automobile tires), and a particleboard are measured and predicted. Finally, a mathematical model to predict the diffusion coefficient through complex sources (floor adhesive) as a function of time was developed. Then this model (for diffusion coefficient in complex sources) was used to predict the emission rate from material system (namely, substrate//glue//vinyl tile).

  12. Numerical determination of lateral loss coefficients for subchannel analysis in nuclear fuel bundles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sin Kim; Goon-Cherl Park

    1995-09-01

    An accurate prediction of cross-flow based on detailed knowledge of the velocity field in subchannels of a nuclear fuel assembly is of importance in nuclear fuel performance analysis. In this study, the low-Reynolds number {kappa}-{epsilon} turbulence model has been adopted in two adjacent subchannels with cross-flow. The secondary flow is estimated accurately by the anisotropic algebraic Reynolds stress model. This model was numerically calculated by the finite element method and has been verified successfully through comparison with existing experimental data. Finally, with the numerical analysis of the velocity field in such subchannel domain, an analytical correlation of the lateral lossmore » coefficient is obtained to predict the cross-flow rate in subchannel analysis codes. The correlation is expressed as a function of the ratio of the lateral flow velocity to the donor subchannel axial velocity, recipient channel Reynolds number and pitch-to-diameter.« less

  13. [Determination of fat, protein and DM in raw milk by portable short-wave near infrared spectrometer].

    PubMed

    Li, Xiao-yun; Wang, Jia-hua; Huang, Ya-wei; Han, Dong-hai

    2011-03-01

    Near infrared diffuse reflectance spectroscopy calibrations of fat, protein and DM in raw milk were studied with partial least-squares (PLS) regression using portable short-wave near infrared spectrometer. The results indicated that good calibrations of fat and DM were found, the correlation coefficients were all 0.98, the RMSEC were 0.187 and 0.217, RMSEP were 0.187 and 0.296, the RPDs were 5.02 and 3.20 respectively; the calibration of protein needed to be improved but can be used for practice, the correlation coefficient was 0.95, RMSEC was 0.105, RMSEP was 0.120, and RPD was 2.60. Furthermore, the measuring accuracy was improved by analyzing the correction relation of fat and DM in raw milk This study will probably provide a new on-site method for nondestructive and rapid measurement of milk.

  14. The relation between tilt table and acceleration-tolerance and their dependence on stature and physical fitness

    NASA Technical Reports Server (NTRS)

    Klein, K. E.; Backhausen, F.; Bruner, H.; Eichhorn, J.; Jovy, D.; Schotte, J.; Vogt, L.; Wegman, H. M.

    1980-01-01

    A group of 12 highly trained athletes and a group of 12untrained students were subjected to passive changes of position on a tilt table and positive accelerations in a centrifuge. During a 20 min tilt, including two additional respiratory maneuvers, the number of faints and average cardiovascular responses did not differ significantly between the groups. During linear increase of acceleration, the average blackout level was almost identical in both groups. Statistically significant coefficients of product-moment correlation for various relations were obtained. The coefficient of multiple determination computed for the dependence of acceleration tolerance on heart-eye distance and systolic blood pressure at rest allows the explanation of almost 50% of the variation of acceleration tolerance. The maximum oxygen uptake showed the expected significant correlation to the heart rate at rest, but not the acceleration tolerance, or to the cardiovascular responses to tilting.

  15. Prediction of kinase-inhibitor binding affinity using energetic parameters

    PubMed Central

    Usha, Singaravelu; Selvaraj, Samuel

    2016-01-01

    The combination of physicochemical properties and energetic parameters derived from protein-ligand complexes play a vital role in determining the biological activity of a molecule. In the present work, protein-ligand interaction energy along with logP values was used to predict the experimental log (IC50) values of 25 different kinase-inhibitors using multiple regressions which gave a correlation coefficient of 0.93. The regression equation obtained was tested on 93 kinase-inhibitor complexes and an average deviation of 0.92 from the experimental log IC50 values was shown. The same set of descriptors was used to predict binding affinities for a test set of five individual kinase families, with correlation values > 0.9. We show that the protein-ligand interaction energies and partition coefficient values form the major deterministic factors for binding affinity of the ligand for its receptor. PMID:28149052

  16. Validation of intracranial area as a surrogate measure of intracranial volume when using clinical MRI.

    PubMed

    Nandigam, R N Kaveer; Chen, Yu-Wei; Gurol, Mahmut E; Rosand, Jonathan; Greenberg, Steven M; Smith, Eric E

    2007-01-01

    We sought to determine whether mid-sagittal intracranial area (ICA) is a valid surrogate of intracranial volume (ICV) when using retrospective data with relatively thick (6-7 mm) sagittal slices. Data were retrospectively analyzed from 47 subjects who had two MRI scans taken at least nine months apart. Twenty-three subjects had manual segmentation of ICV on the T2-weighted sequence for comparison. Intraclass correlation coefficient (ICC) for intraobserver, interobserver, and intraobserver scan-rescan comparisons were 0.96, 0.97 and 0.95. Pearson correlation coefficients between ICV and ICA, averaging the cumulative 1, 2, 3, and 4 most midline slices, were 0.89, 0.94, 0.93, and 0.95. There was a significant marginal increase in explained variance of ICV by measuring two, rather than one, slices (P= 0.001). These data suggest that ICA, even measured without high-resolution imaging, is a reasonable substitute for ICV.

  17. [Estimation of rice LAI by using NDVI at different spectral bandwidths].

    PubMed

    Wang, Fu-min; Huang, Jing-feng; Tang, Yan-lin; Wang, Xiu-zhen

    2007-11-01

    The canopy hyperspectral reflectance data of rice at its different development stages were collected from field measurement, and the corresponding NDVIs as well as the correlation coefficients of NDVIs and LAI were computed at extending bandwidth of TM red and near-infrared (NIR) spectra. According to the variation characteristics of best fitted R2 with spectral bandwidth, the optimal bandwidth was determined. The results showed that the correlation coefficients of LAI and ND-VI and the maximum R2 of the best fitted functions at different spectral bandwidths had the same variation trend, i.e., decreased with increasing bandwidth when the bandwidth was less than 60 nm. However, when the bandwidth was beyond 60 nm, the maximum R2 somewhat fluctuated due to the effect of NIR. The analysis of R2 variation with bandwidth indicated that 15 nm was the optimal bandwidth for the estimation of rice LAI by using NDVI.

  18. Quantized correlation coefficient for measuring reproducibility of ChIP-chip data.

    PubMed

    Peng, Shouyong; Kuroda, Mitzi I; Park, Peter J

    2010-07-27

    Chromatin immunoprecipitation followed by microarray hybridization (ChIP-chip) is used to study protein-DNA interactions and histone modifications on a genome-scale. To ensure data quality, these experiments are usually performed in replicates, and a correlation coefficient between replicates is used often to assess reproducibility. However, the correlation coefficient can be misleading because it is affected not only by the reproducibility of the signal but also by the amount of binding signal present in the data. We develop the Quantized correlation coefficient (QCC) that is much less dependent on the amount of signal. This involves discretization of data into set of quantiles (quantization), a merging procedure to group the background probes, and recalculation of the Pearson correlation coefficient. This procedure reduces the influence of the background noise on the statistic, which then properly focuses more on the reproducibility of the signal. The performance of this procedure is tested in both simulated and real ChIP-chip data. For replicates with different levels of enrichment over background and coverage, we find that QCC reflects reproducibility more accurately and is more robust than the standard Pearson or Spearman correlation coefficients. The quantization and the merging procedure can also suggest a proper quantile threshold for separating signal from background for further analysis. To measure reproducibility of ChIP-chip data correctly, a correlation coefficient that is robust to the amount of signal present should be used. QCC is one such measure. The QCC statistic can also be applied in a variety of other contexts for measuring reproducibility, including analysis of array CGH data for DNA copy number and gene expression data.

  19. Determining Baseline Stress-Related Hormone Values in Large Cetaceans

    DTIC Science & Technology

    2014-09-30

    reconstructed chemical profiles provided a unique window into stress-related hormone (cortisol, aldosterone , T3 and T4) concentrations and...Stress-related hormone radioimmunoassay technique Cortisol, aldosterone , hormones thyroxine (T4) and triiodothyronine (T3) levels in each identified...contaminant concentrations will be calculated using Pearson correlation coefficients. These measurements will include all hormones ( aldosterone , T3

  20. Dealing with Item Nonresponse in Large-Scale Cognitive Assessments: The Impact of Missing Data Methods on Estimated Explanatory Relationships

    ERIC Educational Resources Information Center

    Köhler, Carmen; Pohl, Steffi; Carstensen, Claus H.

    2017-01-01

    Competence data from low-stakes educational large-scale assessment studies allow for evaluating relationships between competencies and other variables. The impact of item-level nonresponse has not been investigated with regard to statistics that determine the size of these relationships (e.g., correlations, regression coefficients). Classical…

  1. Gas-Phase Reaction Pathways and Rate Coefficients for the Dichlorosilane-Hydrogen and Trichlorosilane-Hydrogen Systems

    NASA Technical Reports Server (NTRS)

    Dateo, Christopher E.; Walch, Stephen P.

    2002-01-01

    As part of NASA Ames Research Center's Integrated Process Team on Device/Process Modeling and Nanotechnology our goal is to create/contribute to a gas-phase chemical database for use in modeling microelectronics devices. In particular, we use ab initio methods to determine chemical reaction pathways and to evaluate reaction rate coefficients. Our initial studies concern reactions involved in the dichlorosilane-hydrogen (SiCl2H2--H2) and trichlorosilane-hydrogen (SiCl2H-H2) systems. Reactant, saddle point (transition state), and product geometries and their vibrational harmonic frequencies are determined using the complete-active-space self-consistent-field (CASSCF) electronic structure method with the correlation consistent polarized valence double-zeta basis set (cc-pVDZ). Reaction pathways are constructed by following the imaginary frequency mode of the saddle point to both the reactant and product. Accurate energetics are determined using the singles and doubles coupled-cluster method that includes a perturbational estimate of the effects of connected triple excitations (CCSD(T)) extrapolated to the complete basis set limit. Using the data from the electronic structure calculations, reaction rate coefficients are obtained using conventional and variational transition state and RRKM theories.

  2. Diffusive processes in a stochastic magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, H.; Vlad, M.; Vanden Eijnden, E.

    1995-05-01

    The statistical representation of a fluctuating (stochastic) magnetic field configuration is studied in detail. The Eulerian correlation functions of the magnetic field are determined, taking into account all geometrical constraints: these objects form a nondiagonal matrix. The Lagrangian correlations, within the reasonable Corrsin approximation, are reduced to a single scalar function, determined by an integral equation. The mean square perpendicular deviation of a geometrical point moving along a perturbed field line is determined by a nonlinear second-order differential equation. The separation of neighboring field lines in a stochastic magnetic field is studied. We find exponentiation lengths of both signs describing,more » in particular, a decay (on the average) of any initial anisotropy. The vanishing sum of these exponentiation lengths ensures the existence of an invariant which was overlooked in previous works. Next, the separation of a particle`s trajectory from the magnetic field line to which it was initially attached is studied by a similar method. Here too an initial phase of exponential separation appears. Assuming the existence of a final diffusive phase, anomalous diffusion coefficients are found for both weakly and strongly collisional limits. The latter is identical to the well known Rechester-Rosenbluth coefficient, which is obtained here by a more quantitative (though not entirely deductive) treatment than in earlier works.« less

  3. Colorimetric Glucose Assay Based on Magnetic Particles Having Pseudo-peroxidase Activity and Immobilized Glucose Oxidase.

    PubMed

    Martinkova, Pavla; Opatrilova, Radka; Kruzliak, Peter; Styriak, Igor; Pohanka, Miroslav

    2016-05-01

    Magnetic particles (MPs) are currently used as a suitable alternative for peroxidase in the construction of novel biosensors, analytic and diagnostic methods. Their better chemical and thermal stabilities predestine them as appropriate pseudo-enzymatic catalysts. In this point of view, our research was focused on preparation of simply and fast method for immobilization of glucose oxidase onto surface of MPs with peroxidase-like activity. Spectrophotometric method (wavelength 450 nm) optimized for glucose determination using modified MPs has been successfully developed. Concentration curve for optimization of method was assayed, and Michaelis-Menten constant (K m) calculated, maximum reaction rate (V max), limit of detection, and correlation coefficient were determined to be 0.13 mmol/l (2.34 mg/dl), 1.79 pkat, 3.74 µmol/l (0.067 mg/dl), and 0.996, respectively. Interferences of other sugars such as sucrose, sorbitol, deoxyribose, maltose, and fructose were determined as well as effect of substances presenting in plasma (ascorbic acid, reduced glutathione, trolox, and urea). Results in comparison with positive and negative controls showed no interferences of the other sugars and no influence of plasma substances to measuring of glucose. The constructed method showed corresponding results with linear dependence and a correlation coefficient of 0.997. Possibility of repeated use of modified MPs was successfully proved.

  4. Determination of the carmine content based on spectrum fluorescence spectral and PSO-SVM

    NASA Astrophysics Data System (ADS)

    Wang, Shu-tao; Peng, Tao; Cheng, Qi; Wang, Gui-chuan; Kong, De-ming; Wang, Yu-tian

    2018-03-01

    Carmine is a widely used food pigment in various food and beverage additives. Excessive consumption of synthetic pigment shall do harm to body seriously. The food is generally associated with a variety of colors. Under the simulation context of various food pigments' coexistence, we adopted the technology of fluorescence spectroscopy, together with the PSO-SVM algorithm, so that to establish a method for the determination of carmine content in mixed solution. After analyzing the prediction results of PSO-SVM, we collected a bunch of data: the carmine average recovery rate was 100.84%, the root mean square error of prediction (RMSEP) for 1.03e-04, 0.999 for the correlation coefficient between the model output and the real value of the forecast. Compared with the prediction results of reverse transmission, the correlation coefficient of PSO-SVM was 2.7% higher, the average recovery rate for 0.6%, and the root mean square error was nearly one order of magnitude lower. According to the analysis results, it can effectively avoid the interference caused by pigment with the combination of the fluorescence spectrum technique and PSO-SVM, accurately determining the content of carmine in mixed solution with an effect better than that of BP.

  5. Manure sampling procedures and nutrient estimation by the hydrometer method for gestation pigs.

    PubMed

    Zhu, Jun; Ndegwa, Pius M; Zhang, Zhijian

    2004-05-01

    Three manure agitation procedures were examined in this study (vertical mixing, horizontal mixing, and no mixing) to determine the efficacy of producing a representative manure sample. The total solids content for manure from gestation pigs was found to be well correlated with the total nitrogen (TN) and total phosphorus (TP) concentrations in the manure, with highly significant correlation coefficients of 0.988 and 0.994, respectively. Linear correlations were observed between the TN and TP contents and the manure specific gravity (correlation coefficients: 0.991 and 0.987, respectively). Therefore, it may be inferred that the nutrients in pig manure can be estimated with reasonable accuracy by measuring the liquid manure specific gravity. A rapid testing method for manure nutrient contents (TN and TP) using a soil hydrometer was also evaluated. The results showed that the estimating error increased from +/-10% to +/-30% with the decrease in TN (from 1000 to 100 ppm) and TP (from 700 to 50 ppm) concentrations in the manure. Data also showed that the hydrometer readings had to be taken within 10 s after mixing to avoid reading drift in specific gravity due to the settling of manure solids.

  6. Confidence Intervals and "F" Tests for Intraclass Correlation Coefficients Based on Three-Way Mixed Effects Models

    ERIC Educational Resources Information Center

    Zhou, Hong; Muellerleile, Paige; Ingram, Debra; Wong, Seok P.

    2011-01-01

    Intraclass correlation coefficients (ICCs) are commonly used in behavioral measurement and psychometrics when a researcher is interested in the relationship among variables of a common class. The formulas for deriving ICCs, or generalizability coefficients, vary depending on which models are specified. This article gives the equations for…

  7. SU-F-T-669: Commissioning of An Electronic Brachytherapy System for Targeted Mouse Irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culberson, W; Micka, J; Carchman, E

    Purpose: The aim of this study was to commission the Xoft Axxent™ electronic brachytherapy (eBT) source and 10 mm diameter surface applicator with NIST traceability for targeted irradiations of mouse anal carcinomas. Methods: The Xoft Axxent™ electronic brachytherapy (eBT) and 10 mm diameter surface applicator was chosen by the collaborating physician as a radiation delivery mechanism for mouse anal carcinomas. The target dose was 2 Gy at a depth of 3 mm in tissue to be delivered in a single fraction. To implement an accurate and reliable irradiation plan, the system was commissioned by first determining the eBT source outputmore » and corresponding dose rate at a depth of 3 mm in tissue. This was determined through parallel-plate ion chamber measurements and published conversion factors. Well-type ionization chamber measurements were used to determine a transfer coefficient, which correlates the measured dose rate at 3 mm to the NIST-traceable quantity, air-kerma rate at 50 cm in air, for eBT sources. By correlating these two quantities, daily monitoring in the well chamber becomes an accurate and efficient quality assurance technique. Once the dose-rate was determined, a treatment recipe was developed and confirmed with chamber measurements to deliver the requested dose. Radiochromic film was used to verify the dose distribution across the field. Results: Dose rates at 3 mm depth in tissue were determined for two different Xoft Axxent™ sources and correlated with NIST-traceable well-type ionization chamber measurements. Unique transfer coefficients were determined for each source and the treatment recipe was validated by measurements. Film profiles showed a uniform dose distribution across the field. Conclusion: A Xoft Axxent™ eBT system was successfully commissioned for use in the irradiation of mouse rectal tumors. Dose rates in tissue were determined as well as other pertinent parameters to ensure accurate delivery of dose to the target region.« less

  8. [Quantitative determination of blood regurgitation via the mitral valve].

    PubMed

    Sandrikov, V A

    1981-11-01

    A method of quantitative determination of blood regurgitation through the mitral valve is considered. Verification experiment on 5 animals with the determination of correlation coefficient of true and predicted regurgitation has shown it to be 0.855 on the average. Besides, observations were undertaken on 621 patient with varying pathology of the heart. A quantitative characteristics of blood regurgitation in patients with mitral defects is given. The method can be used not only under operation conditions, but also in catheterization of the cardiac cavities without administering of an opaque substance.

  9. Uses and Misuses of the Correlation Coefficient.

    ERIC Educational Resources Information Center

    Onwuegbuzie, Anthony J.; Daniel, Larry G.

    The purpose of this paper is to provide an in-depth critical analysis of the use and misuse of correlation coefficients. Various analytical and interpretational misconceptions are reviewed, beginning with the egregious assumption that correlational statistics may be useful in inferring causality. Additional misconceptions, stemming from…

  10. Evaluation of icing drag coefficient correlations applied to iced propeller performance prediction

    NASA Technical Reports Server (NTRS)

    Miller, Thomas L.; Shaw, R. J.; Korkan, K. D.

    1987-01-01

    Evaluation of three empirical icing drag coefficient correlations is accomplished through application to a set of propeller icing data. The various correlations represent the best means currently available for relating drag rise to various flight and atmospheric conditions for both fixed-wing and rotating airfoils, and the work presented here ilustrates and evaluates one such application of the latter case. The origins of each of the correlations are discussed, and their apparent capabilities and limitations are summarized. These correlations have been made to be an integral part of a computer code, ICEPERF, which has been designed to calculate iced propeller performance. Comparison with experimental propeller icing data shows generally good agreement, with the quality of the predicted results seen to be directly related to the radial icing extent of each case. The code's capability to properly predict thrust coefficient, power coefficient, and propeller efficiency is shown to be strongly dependent on the choice of correlation selected, as well as upon proper specificatioon of radial icing extent.

  11. Determination of n-octanol/water partition coefficient for DDT-related compounds by RP-HPLC with a novel dual-point retention time correction.

    PubMed

    Han, Shu-ying; Qiao, Jun-qin; Zhang, Yun-yang; Yang, Li-li; Lian, Hong-zhen; Ge, Xin; Chen, Hong-yuan

    2011-03-01

    n-Octanol/water partition coefficients (P) for DDTs and dicofol were determined by reversed-phase high performance liquid chromatography (RP-HPLC) on a C(18) column using methanol-water mixture as mobile phase. A dual-point retention time correction (DP-RTC) was proposed to rectify chromatographic retention time (t(R)) shift resulted from stationary phase aging. Based on this correction, the relationship between logP and logk(w), the logarithm of the retention factor extrapolated to pure water, was investigated for a set of 12 benzene homologues and DDT-related compounds with reliable experimental P as model compounds. A linear regression logP=(1.10±0.04) logk(w) - (0.60±0.17) was established with correlation coefficient R(2) of 0.988, cross-validated correlation coefficient R(cv)(2) of 0.983 and standard deviation (SD) of 0.156. This model was further validated using four verification compounds, naphthalene, biphenyl, 2,2-bis(4-chlorophenyl)-1,1-dichloroethane (p,p'-DDD) and 2,2-bis(4-chlorophenyl)-1,1-dichloroethene (p,p'-DDE) with similar structure to DDT. The RP-HPLC-determined P values showed good consistency with shake-flask (SFM) or slow-stirring (SSM) results, especially for highly hydrophobic compounds with logP in the range of 4-7. Then, the P values for five DDT-related compounds, 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1,1-trichloroethane (o,p'-DDT), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethane (o,p'-DDD), 2-(2-chlorophenyl)-2-(4-chlorophenyl)-1,1-dichloroethene (o,p'-DDE), and 2,2,2-trichloro-1,1-bis(4-chlorophenyl)ethanol (dicofol) and its main degradation product 4,4'-dichlorobenzophenone (p,p'-DBP) were evaluated by the improved RP-HPLC method for the first time. The excellent precision with SD less than 0.03 proved that the novel DP-RTC protocol can significantly increases the determination accuracy and reliability of P by RP-HPLC. Copyright © 2011 Elsevier Ltd. All rights reserved.

  12. Geodesy of Amalthea and the Galilean Satellites of Jupiter

    NASA Astrophysics Data System (ADS)

    Schubert, G.; Anderson, J. D.; Jacobson, R. A.; Lau, E. L.; Moore, W. B.; Palguta, J.

    2003-12-01

    An important scientific legacy of the Galileo mission is the determination of the masses and quadrupole components of the gravitational fields of the Galilean satellites. A final report of the mission results is given including values of GM (G is the universal gravitational constant, M is satellite mass), the gravitational coefficients J2 and C22, and the correlation coefficient μ between J2 and C22. The values of J2 and C22 are deduced using the a priori assumption J2 = (10/3)C22. The least squares method for fitting the Doppler residuals does not fix this ratio, but allows J2 and C22 to vary independently and determines the correlation between them. The a priori assumption is consistent with the hydrostatic equilibrium of a satellite, but it does not require hydrostaticity. Values of μ show that J2 and C22 are independently determined only for Io; the ratio of J2 and C22 is consistent with a hydrostatic Io. J2 and C22 are not independently determined for Ganymede even though there are both equatorial and polar flybys of the satellite. A quadrupole field is insufficient to fit the Ganymede data to the noise level. The additional signal is interpreted in terms of mascon anomalies at the surface of Ganymede. The gravitational coefficients, together with the assumption that the degree~2 gravitational fields of the satellites derive from their hydrostatic distortions to rotation and the Jovian tidal force, are used to infer the moments of inertia of the satellites and their internal structures. The mass and closest approach distance for Amalthea can be determined from Doppler data from the Galileo encounter of 5~November 2002. The final results indicate a density that is significantly smaller than the approximate 1000~kg\\ m-3 density of water ice. The quadrupole components of Amalthea's gravitational field are undetectable in the encounter Doppler data.

  13. Determination of suitable chemical extraction methods for the available iron content of brown forest soils in Turkey

    NASA Astrophysics Data System (ADS)

    Adiloglu, Aydin

    2006-09-01

    The aim of this research was to determine the available iron (Fe) content of brown forest soils of Edirne Province and the most suitable chemical extraction method. Eight chemical extraction methods (the 0.005 M DTPA + 0.01 M CaCl2 + 0.1 MTEA, 0.05 M HCl + 0.012 M H2SO4, 1 M NH4OAc (pH: 4.8), 0.01 M EDTA + 1 M NH4OAc, 1 M MgCl2, 0.01 M EDTA + 1 M (NH4)2CO3, 0.005 M DTPA + 1 M NH4HCO3, and 0.001 M EDDHA methods) and six biological indices (the dry matter yield, Fe concentration, Fe uptake, relative dry matter yield, relative Fe concentration, and relative Fe uptake) were compared. The biological indices were determined with barley (Hordeum vulgare L.) grown under greenhouse conditions. At the end of the experiment, the highest correlation coefficients (r) were determined to be between the 0.005 M DTPA + 0.01 M CaCl2 + 0.1 M TEA method and the biological indices and between the 0.005 M DTPA + 1 M NH4HCO3 method and the biological indices. The corresponding correlation coefficients (r) for the 0.005 M DTPA + 0.01 M CaCl2 + 0.1 M TEA method and the six biological indices were 0.621**, 0.823**, 0.810** 0.433**, 0.558**, and 0.640**, respectively. For the 0.005 M DTPA + 1 M NH4HCO3 method, these coefficients were equal to 0.618**, 0.520**, 0.679**, 0.521**, 0.492**, and 0.641**, respectively (** indicate the validity of the relationships at p < 0.01) These extraction methods, out of all the methods tested, were suggested for the determination of the available Fe content of the brown forest soils.

  14. Family Reintegration Experiences of Soldiers with Mild Traumatic Brain Injury

    DTIC Science & Technology

    2014-02-26

    depression scores in the spouse. Weak within-couple correlation were indicated on the other measures. Table 3 presents the Spearman correlation matrix...separately. Table 2: Spearman Correlation Coefficients for Couples Spouse MAT Spouse Depression Spouse...Anxiety Soldier MAT -0.06 Soldier Depression -0.61 Soldier Anxiety -0.12 Table 3: Spearman Correlation Coefficients for Soldiers and

  15. Correlation tests of the engine performance parameter by using the detrended cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Dong, Keqiang; Gao, You; Jing, Liming

    2015-02-01

    The presence of cross-correlation in complex systems has long been noted and studied in a broad range of physical applications. We here focus on an aero-engine system as an example of a complex system. By applying the detrended cross-correlation (DCCA) coefficient method to aero-engine time series, we investigate the effects of the data length and the time scale on the detrended cross-correlation coefficients ρ DCCA ( T, s). We then show, for a twin-engine aircraft, that the engine fuel flow time series derived from the left engine and the right engine exhibit much stronger cross-correlations than the engine exhaust-gas temperature series derived from the left engine and the right engine do.

  16. Kinetic-dependent enzyme-linked immunosorbent assay for detection of antibodies to Legionella pneumophila.

    PubMed Central

    Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J

    1983-01-01

    A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis. PMID:6361052

  17. Kinetic-dependent enzyme-linked immunosorbent assay for detection of antibodies to Legionella pneumophila.

    PubMed

    Sampson, J S; Wilkinson, H W; Tsang, V C; Brake, B J

    1983-12-01

    A semiautomated, kinetic-dependent, enzyme-linked immunosorbent assay (K-ELISA) was adapted to detect serum antibodies to Legionella pneumophila. In a comparative study, 158 human serum samples (79 pairs) were tested by K-ELISA and the standard indirect immunofluorescence assay for determination of antibody levels to L. pneumophila serogroup 1. K-ELISA determinations were made by using a serogroup-specific antigen or a preparation (unfractionated antigen) which contained both common antigen and serogroup-specific reactivity. There was good correlation between the immunofluorescence assay and the K-ELISA by using either antigen, although greater correlation was achieved with the unfractionated antigen (coefficients of correlation, 0.894 with unfractionated antigen and 0.841 with serogroup-specific antigen). These results indicate that the K-ELISA is a reliable alternative to the immunofluorescence assay for serologically diagnosing legionellosis.

  18. Ultrasonic ranking of toughness of tungsten carbide

    NASA Technical Reports Server (NTRS)

    Vary, A.; Hull, D. R.

    1983-01-01

    The feasibility of using ultrasonic attenuation measurements to rank tungsten carbide alloys according to their fracture toughness was demonstrated. Six samples of cobalt-cemented tungsten carbide (WC-Co) were examined. These varied in cobalt content from approximately 2 to 16 weight percent. The toughness generally increased with increasing cobalt content. Toughness was first determined by the Palmqvist and short rod fracture toughness tests. Subsequently, ultrasonic attenuation measurements were correlated with both these mechanical test methods. It is shown that there is a strong increase in ultrasonic attenuation corresponding to increased toughness of the WC-Co alloys. A correlation between attenuation and toughness exists for a wide range of ultrasonic frequencies. However, the best correlation for the WC-Co alloys occurs when the attenuation coefficient measured in the vicinity of 100 megahertz is compared with toughness as determined by the Palmqvist technique.

  19. Prediction of Very High Reynolds Number Compressible Skin Friction

    NASA Technical Reports Server (NTRS)

    Carlson, John R.

    1998-01-01

    Flat plate skin friction calculations over a range of Mach numbers from 0.4 to 3.5 at Reynolds numbers from 16 million to 492 million using a Navier Stokes method with advanced turbulence modeling are compared with incompressible skin friction coefficient correlations. The semi-empirical correlation theories of van Driest; Cope; Winkler and Cha; and Sommer and Short T' are used to transform the predicted skin friction coefficients of solutions using two algebraic Reynolds stress turbulence models in the Navier-Stokes method PAB3D. In general, the predicted skin friction coefficients scaled well with each reference temperature theory though, overall the theory by Sommer and Short appeared to best collapse the predicted coefficients. At the lower Reynolds number 3 to 30 million, both the Girimaji and Shih, Zhu and Lumley turbulence models predicted skin-friction coefficients within 2% of the semi-empirical correlation skin friction coefficients. At the higher Reynolds numbers of 100 to 500 million, the turbulence models by Shih, Zhu and Lumley and Girimaji predicted coefficients that were 6% less and 10% greater, respectively, than the semi-empirical coefficients.

  20. A Practical Theory of Micro-Solar Power Sensor Networks

    DTIC Science & Technology

    2009-04-20

    Simulation Platform TOSSIM [LLWC03] ns-2 Matlab C++ AVRORA [TLP05] Reference Hardware Mica2 WINS, Medusa Mica Mica2, Medusa Mica2 Simulated Power Power...scale. From this raw data, we can 162 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 2 4 Correlation coefficient F re qu en cy Histogram of correlation...0.5 0.6 0.7 0.8 0.9 1 0 1 2 Correlation coefficient F re qu en cy Histogram of correlation coefficient with solar radiation measurement (Turbidity at

  1. Novel priming and crosslinking systems for use with isocyanatomethacrylate dental adhesives.

    PubMed

    Chappelow, C C; Power, M D; Bowles, C Q; Miller, R G; Pinzino, C S; Eick, J D

    2000-11-01

    (a) to design, formulate and evaluate prototype primers and a crosslinking agent for use with isocyanatomethacrylate-based comonomer adhesives and (b) to establish correlations between bond strength and solubility parameter differences between the adhesives and etched dentin, and the permeability coefficients of the adhesives. Equimolar mixtures of 2-isocyanatoethyl methacrylate (IEM) and a methacrylate comonomer were formulated with tri-n-butyl borane oxide (TBBO) as the free radical initiator to have cure times of 6-10 min. Shear bond strengths to dentin were determined for each adhesive mixture (n = 7) using standard testing protocols. Shear bond strengths for the three systems were also determined after application of "reactive primers" to the dentin surface. The "reactive primers" contained 10-20 parts by weight of the respective comonomer mixture and 3.5 parts by weight TBBO in acetone. Solubility parameters difference values (delta delta) and permeability coefficients (P) were approximated for each adhesive system and correlated with shear bond strength values. Additionally, a crosslinking agent was prepared by bulk reaction of an equimolar mixture containing IEM and a methacrylate comonomer. The effects of crosslinker addition on: (a) the setting time of IEM; and (b) the setting times and initiator requirements of selected IEM/comonomer mixtures were determined. Shear bond strength values (MPa): IEM/HEMA 13.6 +/- 2.0 (no primer), 20.1 +/- 2.0 (with primer); IEM/HETMA 9.3 +/- 3.3 (no primer), 20.8 +/- 8.1 (with primer); IEM/AAEMA 13.6 +/- 1.9 (no primer), 17.3 +/- 3.2 (with primer). Also, approximated permeability coefficients showed a significant correlation (r = +0.867, p < 0.001) with shear bond strength values. Crosslinker addition studies with IEM/4-META: (a) at 5-9 mol% reduced the setting time of IEM polymerization by 79%; and (b) at 6 mol% reduced initiator level requirements 60-70% to achieve a comparable setting time, and decreased setting times by ca. 75% for a given initiator level with selected IEM/methacrylate adhesive systems. The shear bond strengths of isocyanatomethacrylate-based dental adhesives can be enhanced by using reactive primers; their setting times and initiator requirements can be improved using a dimethacrylate crosslinker. Approximated permeability coefficients may be useful as indicators of bonding performance for dentin adhesive systems.

  2. Detrended partial cross-correlation analysis of two nonstationary time series influenced by common external forces

    NASA Astrophysics Data System (ADS)

    Qian, Xi-Yuan; Liu, Ya-Min; Jiang, Zhi-Qiang; Podobnik, Boris; Zhou, Wei-Xing; Stanley, H. Eugene

    2015-06-01

    When common factors strongly influence two power-law cross-correlated time series recorded in complex natural or social systems, using detrended cross-correlation analysis (DCCA) without considering these common factors will bias the results. We use detrended partial cross-correlation analysis (DPXA) to uncover the intrinsic power-law cross correlations between two simultaneously recorded time series in the presence of nonstationarity after removing the effects of other time series acting as common forces. The DPXA method is a generalization of the detrended cross-correlation analysis that takes into account partial correlation analysis. We demonstrate the method by using bivariate fractional Brownian motions contaminated with a fractional Brownian motion. We find that the DPXA is able to recover the analytical cross Hurst indices, and thus the multiscale DPXA coefficients are a viable alternative to the conventional cross-correlation coefficient. We demonstrate the advantage of the DPXA coefficients over the DCCA coefficients by analyzing contaminated bivariate fractional Brownian motions. We calculate the DPXA coefficients and use them to extract the intrinsic cross correlation between crude oil and gold futures by taking into consideration the impact of the U.S. dollar index. We develop the multifractal DPXA (MF-DPXA) method in order to generalize the DPXA method and investigate multifractal time series. We analyze multifractal binomial measures masked with strong white noises and find that the MF-DPXA method quantifies the hidden multifractal nature while the multifractal DCCA method fails.

  3. Cardiopulmonary fitness is strongly associated with body cell mass and fat-free mass: The Study of Health in Pomerania (SHIP).

    PubMed

    Köhler, A; King, R; Bahls, M; Groß, S; Steveling, A; Gärtner, S; Schipf, S; Gläser, S; Völzke, H; Felix, S B; Markus, M R P; Dörr, M

    2018-01-18

    Peak oxygen uptake (VO2peak) is commonly indexed by total body weight (TBW) to determine cardiopulmonary fitness (CPF). This approach may lead to misinterpretation, particularly in obese subjects. We investigated the normalization of VO2peak by different body composition markers. We analyzed combined data of 3848 subjects (1914 women; 49.7%), aged 20-90, from two independent cohorts of the population-based Study of Health in Pomerania (SHIP-2 and SHIP-TREND). VO2peak was assessed by cardiopulmonary exercise testing. Body cell mass (BCM), fat-free mass (FFM), and fat mass (FM) were determined by bioelectrical impedance analysis. The suitability of the different markers as a normalization variable was evaluated by taking into account correlation coefficients (r) and intercept (α-coefficient) values from linear regression models. A combination of high r and low α values was considered as preferable for normalization purposes. BCM was the best normalization variable for VO2peak (r = .72; P ≤ .001; α-coefficient = 63.3 mL/min; 95% confidence interval [CI]: 3.48-123) followed by FFM (r = .63; P ≤ .001; α-coefficient = 19.6 mL/min; 95% CI: -57.9-97.0). On the other hand, a much weaker correlation and a markedly higher intercept were found for TBW (r = .42; P ≤ .001; α-coefficient = 579 mL/min; 95% CI: 483 to 675). Likewise, FM was also identified as a poor normalization variable (r = .10; P ≤ .001; α-coefficient = 2133; 95% CI: 2074-2191). Sex-stratified analyses confirmed the above order for the different normalization variables. Our results suggest that BCM, followed by FFM, might be the most appropriate marker for the normalization of VO2peak when comparing CPF between subjects with different body shape. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Visible and near-infrared bulk optical properties of raw milk.

    PubMed

    Aernouts, B; Van Beers, R; Watté, R; Huybrechts, T; Lammertyn, J; Saeys, W

    2015-10-01

    The implementation of optical sensor technology to monitor the milk quality on dairy farms and milk processing plants would support the early detection of altering production processes. Basic visible and near-infrared spectroscopy is already widely used to measure the composition of agricultural and food products. However, to obtain maximal performance, the design of such optical sensors should be optimized with regard to the optical properties of the samples to be measured. Therefore, the aim of this study was to determine the visible and near-infrared bulk absorption coefficient, bulk scattering coefficient, and scattering anisotropy spectra for a diverse set of raw milk samples originating from individual cow milkings, representing the milk variability present on dairy farms. Accordingly, this database of bulk optical properties can be used in future simulation studies to efficiently optimize and validate the design of an optical milk quality sensor. In a next step of the current study, the relation between the obtained bulk optical properties and milk quality properties was analyzed in detail. The bulk absorption coefficient spectra were found to mainly contain information on the water, fat, and casein content, whereas the bulk scattering coefficient spectra were found to be primarily influenced by the quantity and the size of the fat globules. Moreover, a strong positive correlation (r ≥ 0.975) was found between the fat content in raw milk and the measured bulk scattering coefficients in the 1,300 to 1,400 nm wavelength range. Relative to the bulk scattering coefficient, the variability on the scattering anisotropy factor was found to be limited. This is because the milk scattering anisotropy is nearly independent of the fat globule and casein micelle quantity, while it is mainly determined by the size of the fat globules. As this study shows high correlations between the sample's bulk optical properties and the milk composition and fat globule size, a sensor that allows for robust separation between the absorption and scattering properties would enable accurate prediction of the raw milk quality parameters. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Restoration of acidic mine spoils with sewage sludge: II measurement of solids applied

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stucky, D.J.; Zoeller, A.L.

    1980-01-01

    Sewage sludge was incorporated in acidic strip mine spoils at rates equivalent to 0, 224, 336, and 448 dry metric tons (dmt)/ha and placed in pots in a greenhouse. Spoil parameters were determined 48 hours after sludge incorporation, Time Planting (P), and five months after orchardgrass (Dactylis glomerata L.) was planted, Time Harvest (H), in the pots. Parameters measured were: pH, organic matter content (OM), cation exchange capacity (CEC), electrical conductivity (EC) and yield. Values for each parameter were significantly different at the two sampling times. Correlation coefficient values were calculated for all parameters versus rates of applied sewage sludgemore » and all parameters versus each other. Multiple regressions were performed, stepwise, for all parameters versus rates of applied sewage sludge. Equations to predict amounts of sewage sludge incorporated in spoils were derived for individual and multiple parameters. Generally, measurements made at Time P achieved the highest correlation coefficient and multiple correlation coefficient values; therefore, the authors concluded data from Time P had the greatest predictability value. The most important value measured to predict rate of applied sewage sludge was pH and some additional accuracy was obtained by including CEC in equation. This experiment indicated that soil properties can be used to estimate amounts of sewage sludge solids required to reclaim acidic mine spoils and to estimate quantities incorporated.« less

  6. Willingness to pay for anterior cruciate ligament reconstruction.

    PubMed

    Hall, Michael P; Chiang-Colvin, Alexis S; Bosco, Joseph A

    2013-01-01

    The outcomes of ACL reconstructions in terms of patient satisfaction and function are well known. Most orthopaedic surgeons feel that Medicare and other payors do not reimburse enough for this surgery. The purpose of this study is to determine how much patients are willing to pay for this surgery and compare it to reimbursement rates. We constructed a survey which described the function and limitations of an ACL deficient knee and the expected function of that knee after an ACL reconstruction. We then asked the volunteers how much they would be willing to pay for an ACL reconstruction if it were their knee. We also gathered data on the yearly earnings and Tegner activity level of the volunteers. In all, 143 volunteers completed the survey. We computed correlation coefficients between willingness to pay and both yearly earnings and Tegner activity level. The average amount that the volunteers were willing to pay for an ACL reconstruction was $4,867.00. There was no correlation between yearly earnings and willingness to pay. The correlation coefficient was 0.34. There was a weak correlation between Tegner activity level and willingness to pay. This correlation coefficient was 0.81. The Medicare allowable rate for ACL reconstruction (CPT 29888) in the geographic area of the study was $1,132.00. The data demonstrates that patients are willing to pay much more than traditional payors for ACL reconstruction. These payors undervalue the benefit of this surgery to the patient. There is increasing pressure on orthopaedic surgeons to not participate in insurance plans that reimburse poorly. This places an increasing financial burden on the patient. This study suggests that patients may be willing to pay more for their surgery than their insurance plan and accept more of this burden.

  7. Observations of copolar correlation coefficient through a bright band at vertical incidence

    NASA Technical Reports Server (NTRS)

    Zrnic, D. S.; Raghavan, R.; Chandrasekar, V.

    1994-01-01

    This paper discusses an application of polarimetric measurements at vertical incidence. In particular, the correlation coefficients between linear copolar components are examined, and measurements obtained with the National Severe Storms Laboratory (NSSL)'s and National Center for Atmospheric Research (NCAR)'s polarimetric radars are presented. The data are from two well-defined bright bands. A sharp decrease of the correlation coefficient, confined to a height interval of a few hundred meters, marks the bottom of the bright band.

  8. Relationship of body mass index to percent body fat and waist circumference among schoolchildren in Japan--the influence of gender and obesity: a population-based cross-sectional study.

    PubMed

    Ochiai, Hirotaka; Shirasawa, Takako; Nishimura, Rimei; Morimoto, Aya; Shimada, Naoki; Ohtsu, Tadahiro; Kujirai, Emiko; Hoshino, Hiromi; Tajima, Naoko; Kokaze, Akatsuki

    2010-08-18

    Although the correlation coefficient between body mass index (BMI) and percent body fat (%BF) or waist circumference (WC) has been reported, studies conducted among population-based schoolchildren to date have been limited in Japan, where %BF and WC are not usually measured in annual health examinations at elementary schools or junior high schools. The aim of the present study was to investigate the relationship of BMI to %BF and WC and to examine the influence of gender and obesity on these relationships among Japanese schoolchildren. Subjects included 3,750 schoolchildren from the fourth and seventh grade in Ina-town, Saitama Prefecture, Japan between 2004 and 2008. Information about subject's age, sex, height, weight, %BF, and WC was collected from annual physical examinations. %BF was measured with a bipedal biometrical impedance analysis device. Obesity was defined by the following two criteria: the obese definition of the Centers for Disease Control and Prevention, and the definition of obesity for Japanese children. Pearson's correlation coefficients between BMI and %BF or WC were calculated separately for sex. Among fourth graders, the correlation coefficients between BMI and %BF were 0.74 for boys and 0.97 for girls, whereas those between BMI and WC were 0.94 for boys and 0.90 for girls. Similar results were observed in the analysis of seventh graders. The correlation coefficient between BMI and %BF varied by physique (obese or non-obese), with weaker correlations among the obese regardless of the definition of obesity; most correlation coefficients among obese boys were less than 0.5, whereas most correlations among obese girls were more than 0.7. On the other hand, the correlation coefficients between BMI and WC were more than 0.8 among boys and almost all coefficients were more than 0.7 among girls, regardless of physique. BMI was positively correlated with %BF and WC among Japanese schoolchildren. The correlations could be influenced by obesity as well as by gender. Accordingly, it is essential to consider gender and obesity when using BMI as a surrogate for %BF and WC for epidemiological use.

  9. Trace elements in seminal plasma of men from infertile couples.

    PubMed

    Guzikowski, Wojciech; Szynkowska, Małgorzata I; Motak-Pochrzęst, Hanna; Pawlaczyk, Aleksandra; Sypniewski, Stanisław

    2015-06-19

    An analysis of lead, zinc, cadmium and other trace elements in semen of men from infertile couples was performed to determine the association between abnormal semen parameters and enviromental or occupational exposure to some trace metals. Presence of manganese, cobalt, nickel, copper, zinc, molybdenum, cadmium, tin and lead was measured in seminal plasma of 34 men from infertile couples using spectrometry with time-of-flight analysis. Correlations among sperm parameters and trace metals were determined using cluster analysis and Pearson's correlation coefficient. Abnormally high concentrations of lead, cadmium, zinc and cobalt were found in 23 seminal plasma of men from infertile couples. The most consistent evidence was determined for an association between high cadmium concentration in seminal plasma and sperm count, motility and morphology below reference limits (p < 0.01). A correlation of significantly increased tin level and reduced sperm count in semen of men with limited fertility potential was observed (p = 0.04). In our study we observed a correlation of tin level with sperm count in semen of men with limited fertility potential.

  10. Quantitative skeletal evaluation based on cervical vertebral maturation: a longitudinal study of adolescents with normal occlusion.

    PubMed

    Chen, L; Liu, J; Xu, T; Long, X; Lin, J

    2010-07-01

    The study aims were to investigate the correlation between vertebral shape and hand-wrist maturation and to select characteristic parameters of C2-C5 (the second to fifth cervical vertebrae) for cervical vertebral maturation determination by mixed longitudinal data. 87 adolescents (32 males, 55 females) aged 8-18 years with normal occlusion were studied. Sequential lateral cephalograms and hand-wrist radiographs were taken annually for 6 consecutive years. Lateral cephalograms were divided into 11 maturation groups according to Fishman Skeletal Maturity Indicators (SMI). 62 morphological measurements of C2-C5 at 11 different developmental stages (SMI1-11) were measured and analysed. Locally weighted scatterplot smoothing, correlation coefficient analysis and variable cluster analysis were used for statistical analysis. Of the 62 cervical vertebral parameters, 44 were positively correlated with SMI, 6 were negatively correlated and 12 were not correlated. The correlation coefficients between cervical vertebral parameters and SMI were relatively high. Characteristic parameters for quantitative analysis of cervical vertebral maturation were selected. In summary, cervical vertebral maturation could be used reliably to evaluate the skeletal stage instead of the hand-wrist radiographic method. Selected characteristic parameters offered a simple and objective reference for the assessment of skeletal maturity and timing of orthognathic surgery. Copyright 2010 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Screening of young competitive athletes for the prevention of sudden cardiac death with a wireless electrocardiographic transmission device: a pilot study.

    PubMed

    Cho, Jae Hyung; Selen, Mats A; Kocheril, Abraham G

    2015-08-11

    The 12-lead electrocardiographic screening for the prevention of sudden cardiac death in young competitive athletes is not cost-effective and thus not routinely recommended. We investigate whether a less expensive wireless electrocardiographic transmission device can be used to screen for the prevention of sudden cardiac death in this population. During pre-participation screening, twenty college football players underwent two electrocardiograms: a conventional 12-lead electrocardiogram and a wireless 9-lead electrocardiogram. We compared several electrocardiographic parameters (QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria, ST deviation and corrected QT interval) to determine the correlation. The QRS duration, left ventricular hypertrophy using the Cornell voltage criteria and the Sokolow-Lyon criteria and corrected QT interval exhibited significant correlation between the two types of electrocardiograms (correlation coefficient 0.878, 0.630, 0.770 and 0.847, respectively with P values of 0.01, 0.003, 0.01 and 0.01, respectively). ST deviation in V1 was weakly correlated between the two types of electrocardiograms without statistical significance (correlation coefficient 0.360 with a P value of 0.119). Our newly developed wireless 9-lead electrocardiogram demonstrated significant correlations with a conventional 12-lead electrocardiogram in terms of QRS duration, left ventricular hypertrophy and corrected QT interval.

  12. Prevalence of low back disorders among female workers and biomechanical limits on the handling of load and patients.

    PubMed

    Gutiérrez, Manuel; Monzó, Jorge

    2012-01-01

    The purpose of this investigation was to determine the association between prevalence of low back disorders in female workers and biomechanical demands of compressive and shear forces at the lumbar spine. A descriptive, cross-sectional and correlational study was carried out in 11 groups of female workers in the Province of Concepción. An interview was performed to investigate the prevalence of low back pain. To estimate biomechanical demands on the lumbar spine, it was used the 3DSSPP software. The Pearson correlation coefficient between the prevalence of low back disorders and peak compression force at the lumbar spine was r = (p<0.005). The Spearman correlation coefficient between the prevalence of low back disorders and peak shear force was r = 0.9 (p <0.005). To protect 90% of female workers studied, the limits of compression and shear forces should be at 2.8 kN and 0.3 kN, respectively. These values differ from the recommendations currently used, 3.4 kN for peak compression force and 0.5 kN for peak shear force.

  13. A practical formula for determining growth.

    PubMed

    Türkoz, Çağrı; Kaygısız, Emine; Ulusoy, Çağrı; Ateş, Can

    2017-01-01

    We aimed to establish a practical method to evaluate skeletal age using cervical vertebrae. The study consisted of hand-wrist and cephalometric radiographs of 324 subjects (167 girls, 157 boys; age range, 7.3-17.2 years). Skeletal ages of the subjects were calculated from hand-wrist radiographs, and cervical vertebral bodies were measured using cephalometric radiographs. A single formula based on C3 and C4 vertebral body heights with different coefficients for each gender was derived using ridge regression analysis. The correlation coefficients for vertebral and hand-wrist bone age were 0.825 and 0.856 for girls and boys, respectively. The correlations among vertebral bone age and C3 and C4 vertebral body heights were also found to be significant. The intraclass correlation (ICC) score was found to be 0.914, which shows high consistency between the two measurements of the same investigator for each C3 and C4 vertebral body height result. The formula derived for evaluating skeletal age in cephalometric radiographs is reliable and can be applied to both girl and boy subjects for legal requirements or therapeutic needs of age estimation.

  14. Correlation of high-temperature stability of alpha-chymotrypsin with 'salting-in' properties of solution.

    PubMed

    Levitsky VYu; Panova, A A; Mozhaev, V V

    1994-01-15

    A correlation between the stability of alpha-chymotrypsin against irreversible thermal inactivation at high temperatures (long-term stability) and the coefficient of Setchenov equation as a measure of salting-in/out efficiency of solutes in the Hofmeister series has been found. An increase in the concentration of salting-in solutes (KSCN, urea, guanidinium chloride, formamide) leads to a many-fold decrease of the inactivation rate of the enzyme. In contrast, addition of salting-out solutes has a small effect on the long-term stability of alpha-chymotrypsin at high temperatures. The effects of solutes are additive with respect to their salting-in/out capacities; the stabilizing action of the solutes is determined by the calculated Setchenov coefficient of solution. The correlation is explained by a solute-driven shift of the conformational equilibrium between the 'low-temperature' native and the 'high-temperature' denatured forms of the enzyme within the range of the kinetic scheme put forward in the preceding paper in this journal: irreversible inactivation of the high-temperature form proceeds much more slowly compared with the low-temperature form.

  15. Telemedicine Versus Face-to-Face Evaluations by Respiratory Therapists of Mechanically Ventilated Neonates and Children: A Pilot Study.

    PubMed

    Bell, Rebecca C; Yager, Phoebe H; Clark, Maureen E; Roumiantsev, Serguei; Venancio, Heather L; Chipman, Daniel W; Kacmarek, Robert M; Noviski, Natan N

    2016-02-01

    Mechanical ventilation is one of the most important therapeutic interventions in neonatal and pediatric ICUs. Telemedicine has been shown to reliably extend pediatric intensivist expertise to facilities where expertise is limited. If reliable, telemedicine may extend the reach of pediatric respiratory therapists (RTs) to facilities where expertise does not exist or free up existing RT resources for important face-to-face activities in facilities where expertise is limited. The aim of this study was to determine how well respiratory assessments for ventilated neonates and children correlated when performed simultaneously by 2 RTs face-to-face and via telemedicine. We conducted a pilot study including 40 assessments by 16 RTs on 11 subjects (5 neonatal ICU; 6 pediatric ICU). Anonymously completed intake forms by 2 different RTs concurrently assessing 14 ventilator-derived and patient-based respiratory variables were used to determine correlations. Forty paired assessments were performed. Median telemedicine assessment time was 8 min. The Pearson correlation coefficient (r) was used to determine agreement between continuous data, and the Cohen kappa statistics were used for binary variables. Pressure control, PEEP, breathing frequency, and FIO2 perfectly correlated (r = 1, all P < .001) as did the presence of a CO2 monitor and need for increased ventilatory support (kappa = 1). The Pearson correlation coefficient for VT, minute ventilation, mean airway pressure, and oxygen saturation ranged from 0.84 to 0.97 (all P < .001). kappa = 0.41 (95% CI 0.02-0.80) for patient-triggered breaths, and kappa = 0.57 (95% CI 0.19-0.94) for breathing frequency higher than set frequency. kappa = -0.25 (95% CI -0.46 to -0.04) for need for suctioning. Telemedicine technology was acceptable to RTs. Telemedicine evaluations highly correlated with face-to-face for 10 of 14 aspects of standard bedside respiratory assessment. Poor correlation was noted for more complex, patient-generated parameters, highlighting the importance of further investigation incorporating a virtual stethoscope. Copyright © 2016 by Daedalus Enterprises.

  16. Sorption capacity of plastic debris for hydrophobic organic chemicals.

    PubMed

    Lee, Hwang; Shim, Won Joon; Kwon, Jung-Hwan

    2014-02-01

    The occurrence of microplastics (MPs) in the ocean is an emerging world-wide concern. Due to high sorption capacity of plastics for hydrophobic organic chemicals (HOCs), sorption may play an important role in the transport processes of HOCs. However, sorption capacity of various plastic materials is rarely documented except in the case of those used for environmental sampling purposes. In this study, we measured partition coefficients between MPs and seawater (KMPsw) for 8 polycyclic aromatic hydrocarbons (PAHs), 4 hexachlorocyclohexanes (HCHs) and 2 chlorinated benzenes (CBs). Three surrogate polymers - polyethylene, polypropylene, and polystyrene - were used as model plastic debris because they are the major components of microplastic debris found. Due to the limited solubility of HOCs in seawater and their long equilibration time, a third-phase partitioning method was used for the determination of KMPsw. First, partition coefficients between polydimethylsiloxane (PDMS) and seawater (KPDMSsw) were measured. For the determination of KMPsw, the distribution of HOCs between PDMS or plastics and solvent mixture (methanol:water=8:2 (v/v)) was determined after apparent equilibrium up to 12 weeks. Plastic debris was prepared in a laboratory by physical crushing; the median longest dimension was 320-440 μm. Partition coefficients between polyethylene and seawater obtained using the third-phase equilibrium method agreed well with experimental partition coefficients between low-density polyethylene and water in the literature. The values of KMPsw were generally in the order of polystyrene, polyethylene, and polypropylene for most of the chemicals tested. The ranges of log KMPsw were 2.04-7.87, 2.18-7.00, and 2.63-7.52 for polyethylene, polypropylene, and polystyrene, respectively. The partition coefficients of plastic debris can be as high as other frequently used partition coefficients, such as 1-octanol-water partition coefficients (Kow) and log KMPsw showed good linear correlations with log Kow. High sorption capacity of microplastics implies the importance of MP-associated transport of HOCs in the marine environment. © 2013 Elsevier B.V. All rights reserved.

  17. Estimation of health-related-quality of life depends on which utility measure is selected for patients with carpal tunnel syndrome.

    PubMed

    Nazari, Goris; MacDermid, Joy C; Bain, James; Levis, Carolyn M; Thoma, Achilleas

    Cross-sectional. Carpal tunnel syndrome (CTS) refers to the compression neuropathy of the median nerve at the wrist. To establish the interinstrument reliability, convergent construct validity, and the levels of agreement of health utility indexes 2 and 3 (HUI-2 and HUI-3), EuroQol 5-dimensions (EQ-5D), EuroQol-visual analog scale (EQ-VAS) and to determine the difference of these utility measures based on age and gender in patients with carpal tunnel syndrome. Seventy-four patients with a confirmed diagnosis of carpal tunnel syndrome completed the 3 questionnaires and EQ-VAS a month before surgery. Demographic characteristics were reported. Intraclass correlation coefficients were used to assess relative interinstrument reliability. Pearson correlation coefficients (r) were used to establish convergent construct validity. Bland-Altman plots and t tests were used to describe the levels of agreement between the 4 utility measures. A 2-way analysis of variance was performed to determine the effect of age and gender on the utility measures; HUI-2, HUI-3, and EQ-5D. The intraclass correlation coefficients were 0.85 for HUI-3 vs HUI-2 and 0.80 for HUI-2 vs EQ-VAS. Pearson correlation coefficients ranged from 0.60 to 0.89; HUI-3 vs HUI-2: 0.89, and HUI-3 vs EQ-5D: 0.60. One-sample t test demonstrated significant differences between HUI-3 vs HUI-2, HUI-3 vs EQ-5D, and HUI-3 vs EQ-VAS measures, with mean differences of -0.12, -0.15, and -0.14, respectively. A 2-way analysis of variance test controlling for age and gender indicated neither as predictors of outcome scores. The HUI-3 vs HUI-2 and HUI-2 vs EQ-VAS demonstrated excellent interinstrument relative reliability measures. The HUI-3 vs HUI-2 displayed very strong convergent construct validity measures, and strong validity measures were established between the remaining utility measures. In addition, the pair-wise utility comparisons demonstrated minimal bias between HUI-2 vs EQ-5D, HUI-2 vs EQ-VAS, and EQ-VAS vs EQ-5D measures. N/A. N/A. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  18. Digital image analysis of Ki67 proliferation index in breast cancer using virtual dual staining on whole tissue sections: clinical validation and inter-platform agreement.

    PubMed

    Koopman, Timco; Buikema, Henk J; Hollema, Harry; de Bock, Geertruida H; van der Vegt, Bert

    2018-05-01

    The Ki67 proliferation index is a prognostic and predictive marker in breast cancer. Manual scoring is prone to inter- and intra-observer variability. The aims of this study were to clinically validate digital image analysis (DIA) of Ki67 using virtual dual staining (VDS) on whole tissue sections and to assess inter-platform agreement between two independent DIA platforms. Serial whole tissue sections of 154 consecutive invasive breast carcinomas were stained for Ki67 and cytokeratin 8/18 with immunohistochemistry in a clinical setting. Ki67 proliferation index was determined using two independent DIA platforms, implementing VDS to identify tumor tissue. Manual Ki67 score was determined using a standardized manual counting protocol. Inter-observer agreement between manual and DIA scores and inter-platform agreement between both DIA platforms were determined and calculated using Spearman's correlation coefficients. Correlations and agreement were assessed with scatterplots and Bland-Altman plots. Spearman's correlation coefficients were 0.94 (p < 0.001) for inter-observer agreement between manual counting and platform A, 0.93 (p < 0.001) between manual counting and platform B, and 0.96 (p < 0.001) for inter-platform agreement. Scatterplots and Bland-Altman plots revealed no skewness within specific data ranges. In the few cases with ≥ 10% difference between manual counting and DIA, results by both platforms were similar. DIA using VDS is an accurate method to determine the Ki67 proliferation index in breast cancer, as an alternative to manual scoring of whole sections in clinical practice. Inter-platform agreement between two different DIA platforms was excellent, suggesting vendor-independent clinical implementability.

  19. A Method for Approximating the Bivariate Normal Correlation Coefficient.

    ERIC Educational Resources Information Center

    Kirk, David B.

    Improvements of the Gaussian quadrature in conjunction with the Newton-Raphson iteration technique (TM 000 789) are discussed as effective methods of calculating the bivariate normal correlation coefficient. (CK)

  20. Semi-quantitative spectrographic analysis and rank correlation in geochemistry

    USGS Publications Warehouse

    Flanagan, F.J.

    1957-01-01

    The rank correlation coefficient, rs, which involves less computation than the product-moment correlation coefficient, r, can be used to indicate the degree of relationship between two elements. The method is applicable in situations where the assumptions underlying normal distribution correlation theory may not be satisfied. Semi-quantitative spectrographic analyses which are reported as grouped or partly ranked data can be used to calculate rank correlations between elements. ?? 1957.

  1. Robust Approximations to the Non-Null Distribution of the Product Moment Correlation Coefficient I: The Phi Coefficient.

    ERIC Educational Resources Information Center

    Edwards, Lynne K.; Meyers, Sarah A.

    Correlation coefficients are frequently reported in educational and psychological research. The robustness properties and optimality among practical approximations when phi does not equal 0 with moderate sample sizes are not well documented. Three major approximations and their variations are examined: (1) a normal approximation of Fisher's Z,…

  2. Correcting Coefficient Alpha for Correlated Errors: Is [alpha][K]a Lower Bound to Reliability?

    ERIC Educational Resources Information Center

    Rae, Gordon

    2006-01-01

    When errors of measurement are positively correlated, coefficient alpha may overestimate the "true" reliability of a composite. To reduce this inflation bias, Komaroff (1997) has proposed an adjusted alpha coefficient, ak. This article shows that ak is only guaranteed to be a lower bound to reliability if the latter does not include correlated…

  3. Prediction of stream volatilization coefficients

    USGS Publications Warehouse

    Rathbun, Ronald E.

    1990-01-01

    Equations are developed for predicting the liquid-film and gas-film reference-substance parameters for quantifying volatilization of organic solutes from streams. Molecular weight and molecular-diffusion coefficients of the solute are used as correlating parameters. Equations for predicting molecular-diffusion coefficients of organic solutes in water and air are developed, with molecular weight and molal volume as parameters. Mean absolute errors of prediction for diffusion coefficients in water are 9.97% for the molecular-weight equation, 6.45% for the molal-volume equation. The mean absolute error for the diffusion coefficient in air is 5.79% for the molal-volume equation. Molecular weight is not a satisfactory correlating parameter for diffusion in air because two equations are necessary to describe the values in the data set. The best predictive equation for the liquid-film reference-substance parameter has a mean absolute error of 5.74%, with molal volume as the correlating parameter. The best equation for the gas-film parameter has a mean absolute error of 7.80%, with molecular weight as the correlating parameter.

  4. Two-Way Gene Interaction From Microarray Data Based on Correlation Methods

    PubMed Central

    Alavi Majd, Hamid; Talebi, Atefeh; Gilany, Kambiz; Khayyer, Nasibeh

    2016-01-01

    Background Gene networks have generated a massive explosion in the development of high-throughput techniques for monitoring various aspects of gene activity. Networks offer a natural way to model interactions between genes, and extracting gene network information from high-throughput genomic data is an important and difficult task. Objectives The purpose of this study is to construct a two-way gene network based on parametric and nonparametric correlation coefficients. The first step in constructing a Gene Co-expression Network is to score all pairs of gene vectors. The second step is to select a score threshold and connect all gene pairs whose scores exceed this value. Materials and Methods In the foundation-application study, we constructed two-way gene networks using nonparametric methods, such as Spearman’s rank correlation coefficient and Blomqvist’s measure, and compared them with Pearson’s correlation coefficient. We surveyed six genes of venous thrombosis disease, made a matrix entry representing the score for the corresponding gene pair, and obtained two-way interactions using Pearson’s correlation, Spearman’s rank correlation, and Blomqvist’s coefficient. Finally, these methods were compared with Cytoscape, based on BIND, and Gene Ontology, based on molecular function visual methods; R software version 3.2 and Bioconductor were used to perform these methods. Results Based on the Pearson and Spearman correlations, the results were the same and were confirmed by Cytoscape and GO visual methods; however, Blomqvist’s coefficient was not confirmed by visual methods. Conclusions Some results of the correlation coefficients are not the same with visualization. The reason may be due to the small number of data. PMID:27621916

  5. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients

    PubMed Central

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    AIM To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. METHODS Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. RESULTS Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. CONCLUSION Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically. PMID:29181314

  6. Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients.

    PubMed

    Yu, Sha-Sha; Song, Hui; Tang, Xin

    2017-01-01

    To determine the repeatability of Ophtha Top topography and assess the consistency with intraocular lens (IOL)-Master and LenstarLS900 (Lenstar) in measuring corneal parameters among cataract patients. Totally 125 eyes were enrolled. Corneas were successively measured with Ophtha Top, IOL-Master and Lenstar at least three times. The flattest meridian power (Kf), the steepest meridian power (Ks), mean power (Km), J0 and J45 were recorded. Intra-class correlation coefficients (ICCs), the coefficient of variance (COV), within subject standard deviation (Sw), and test-retest repeatability (2.77Sw) were adopted to determine the repeatability. The 95% limit of agreement (95%LOA) and Bland-Altman plots were used to assess comparability. Repeatability of Ophtha Top topography for measuring corneal parameters showed the ICCs were all above 0.93, 2.77Sw was lower than 0.31, and the COV of the Kf and Ks was lower than 0.25. The keratometric readings with Ophtha Top topography were flatter than with the IOL-Master and Lenstar devices, while the Pearson correlation coefficients were over 0.97. The J0 and J45 with Ophtha Top topography were smaller compared with Lenstar and IOL-Master, while was comparable between Lenstar and IOL-Master. Ophtha Top topography shows excellent repeatability for measuring corneal parameters. However, differences between the Ophtha TOP topography and Lenstar, IOL-Master both in cornea curvature and the astigmatism should be noted clinically.

  7. A new computer-based Farnsworth Munsell 100-hue test for evaluation of color vision.

    PubMed

    Ghose, Supriyo; Parmar, Twinkle; Dada, Tanuj; Vanathi, Murugesan; Sharma, Sourabh

    2014-08-01

    To evaluate a computer-based Farnsworth-Munsell (FM) 100-hue test and compare it with a manual FM 100-hue test in normal and congenital color-deficient individuals. Fifty color defective subjects and 200 normal subjects with a best-corrected visual acuity ≥ 6/12 were compared using a standard manual FM 100-hue test and a computer-based FM 100-hue test under standard operating conditions as recommended by the manufacturer after initial trial testing. Parameters evaluated were total error scores (TES), type of defect and testing time. Pearson's correlation coefficient was used to determine the relationship between the test scores. Cohen's kappa was used to assess agreement of color defect classification between the two tests. A receiver operating characteristic curve was used to determine the optimal cut-off score for the computer-based FM 100-hue test. The mean time was 16 ± 1.5 (range 6-20) min for the manual FM 100-hue test and 7.4 ± 1.4 (range 5-13) min for the computer-based FM 100-hue test, thus reducing testing time to <50 % (p < 0.05). For grading color discrimination, Pearson's correlation coefficient for TES between the two tests was 0.91 (p < 0.001). For color defect classification, Cohen's agreement coefficient was 0.98 (p < 0.01). The computer-based FM 100-hue is an effective and rapid method for detecting, classifying and grading color vision anomalies.

  8. Anthropometry for design for the elderly.

    PubMed

    Kothiyal, K; Tettey, S

    2001-01-01

    This paper presents anthropometric data on elderly people in Australia. Data were collected in the metropolitan city of Sydney, NSW, Australia. In all 171 elderly people (males and females, aged 65 years and above) took part in the study. Mean values, standard deviations, medians, range, and coefficients of variation for the various body dimensions were estimated. Correlation coefficients were also calculated to determine the relationship between different body dimensions for the elderly population. The mean stature of elderly Australian males and females were compared with populations from other countries. The paper discusses design implications for elderly people and provides several examples of application of the anthropometric data.

  9. In Vivo High-Frequency, Contrast-Enhanced Ultrasonography of Uveal Melanoma in Mice: Imaging Features and Histopathologic Correlations

    PubMed Central

    Zhang, Qing; Yang, Hua; Kang, Shin J.; Wang, Yanggan; Wang, Geoffrey D.; Coulthard, Tonya

    2011-01-01

    Purpose. To evaluate the usefulness of in vivo imaging of uveal melanoma in mice using high-frequency contrast-enhanced ultrasound (HF-CE-US) with 2D or 3D modes and to correlate the sonographic findings with histopathologic characteristics. Methods. Fourteen 12-week-old C57BL6 mice were inoculated into their right eyes with aliquots of 5 × 105/2.5 μL B16LS9 melanoma cells and were randomly assigned to either of two groups. At 7 days after inoculation, tumor-bearing eyes in group 1 (n = 8) were imaged using HF-CE-US to determine the 2D tumor size and relative blood volume; eyes in group 2 (n = 6) were imaged by 3D microbubble contrast-enhanced ultrasound, and the tumor volume was determined. Histologic tumor burden was quantified in enucleated eyes by image processing software, and microvascular density was determined by counting von Willebrand factor-positive vascular channels. Ultrasound images were evaluated and compared with histopathologic findings. Results. Using HF-CE-US, melanomas were visualized as relatively hyperechoic regions. The intraobserver variability of sonographic measurements was 9.65% ± 7.89%, and the coefficient of variation for multiple measurements was 7.33% ± 5.71%. The correlation coefficient of sonographic volume or size and histologic area was 0.71 (P = 0.11) and 0.79 (P = 0.32). The relative blood volume within the tumor demonstrated sonographically correlated significantly with histologic tumor vascularity (r = 0.83; P < 0.001). Conclusions. There was a positive linear correlation between sonographic tumor measurements and histologic tumor burden in the mouse ocular melanoma model. Contrast-enhanced intensity corresponded with microvascular density and blood volume. HF-CE-US is a real-time, noninvasive, reliable method for in vivo evaluation of experimental intraocular melanoma tumor area and relative blood volume. PMID:21245408

  10. Python Waveform Cross-Correlation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Templeton, Dennise

    PyWCC is a tool to compute seismic waveform cross-correlation coefficients on single-component or multiple-component seismic data across a network of seismic sensors. PyWCC compares waveform data templates with continuous seismic data, associates the resulting detections, identifies the template with the highest cross-correlation coefficient, and outputs a catalog of detections above a user-defined absolute cross-correlation threshold value.

  11. Hadamard multimode optical imaging transceiver

    DOEpatents

    Cooke, Bradly J; Guenther, David C; Tiee, Joe J; Kellum, Mervyn J; Olivas, Nicholas L; Weisse-Bernstein, Nina R; Judd, Stephen L; Braun, Thomas R

    2012-10-30

    Disclosed is a method and system for simultaneously acquiring and producing results for multiple image modes using a common sensor without optical filtering, scanning, or other moving parts. The system and method utilize the Walsh-Hadamard correlation detection process (e.g., functions/matrix) to provide an all-binary structure that permits seamless bridging between analog and digital domains. An embodiment may capture an incoming optical signal at an optical aperture, convert the optical signal to an electrical signal, pass the electrical signal through a Low-Noise Amplifier (LNA) to create an LNA signal, pass the LNA signal through one or more correlators where each correlator has a corresponding Walsh-Hadamard (WH) binary basis function, calculate a correlation output coefficient for each correlator as a function of the corresponding WH binary basis function in accordance with Walsh-Hadamard mathematical principles, digitize each of the correlation output coefficient by passing each correlation output coefficient through an Analog-to-Digital Converter (ADC), and performing image mode processing on the digitized correlation output coefficients as desired to produce one or more image modes. Some, but not all, potential image modes include: multi-channel access, temporal, range, three-dimensional, and synthetic aperture.

  12. Serial diffusion-weighted imaging in subacute sclerosing panencephalitis.

    PubMed

    Kanemura, Hideaki; Aihara, Masao

    2008-06-01

    Subacute sclerosing panencephalitis may be associated with clinical features of frontal lobe dysfunction. We previously reported that frontal lobe volume falls significantly as clinical stage progresses, using three-dimensional magnetic resonance imaging-based brain volumetry. The hypothesis that frontal volume increases correlate with clinical improvement, however, was not tested in our previous study. Therefore, we reevaluated our patient with subacute sclerosing panencephalitis, to determine whether apparent diffusion coefficient maps can characterize the clinical course of subacute sclerosing panencephalitis. We studied an 8-year-old boy with subacute sclerosing panencephalitis, using serial diffusion-weighted imaging magnetic resonance imaging, and measured the regional apparent diffusion coefficient. The regional apparent diffusion coefficient of the frontal lobe decreased significantly with clinical progression, whereas it increased to within normal range during clinical improvements. The apparent diffusion coefficient of the other regions did not change. These results suggest that the clinical signs of patients with subacute sclerosing panencephalitis are attributable to frontal lobe dysfunction, and that apparent diffusion coefficient measurements may be useful in predicting the clinical course of subacute sclerosing panencephalitis.

  13. Relative validity of an FFQ to estimate daily food and nutrient intakes for Chilean adults.

    PubMed

    Dehghan, Mahshid; Martinez, Solange; Zhang, Xiaohe; Seron, Pamela; Lanas, Fernando; Islam, Shofiqul; Merchant, Anwar T

    2013-10-01

    FFQ are commonly used to rank individuals by their food and nutrient intakes in large epidemiological studies. The purpose of the present study was to develop and validate an FFQ to rank individuals participating in an ongoing Prospective Urban and Rural Epidemiological (PURE) study in Chile. An FFQ and four 24 h dietary recalls were completed over 1 year. Pearson correlation coefficients, energy-adjusted and de-attenuated correlations and weighted kappa were computed between the dietary recalls and the FFQ. The level of agreement between the two dietary assessment methods was evaluated by Bland-Altman analysis. Temuco, Chile. Overall, 166 women and men enrolled in the present study. One hundred men and women participated in FFQ development and sixty-six individuals participated in FFQ validation. The FFQ consisted of 109 food items. For nutrients, the crude correlation coefficients between the dietary recalls and FFQ varied from 0.14 (protein) to 0.44 (fat). Energy adjustment and de-attenuation improved correlation coefficients and almost all correlation coefficients exceeded 0.40. Similar correlation coefficients were observed for food groups; the highest de-attenuated energy adjusted correlation coefficient was found for margarine and butter (0.75) and the lowest for potatoes (0.12). The FFQ showed moderate to high agreement for most nutrients and food groups, and can be used to rank individuals based on energy, nutrient and food intakes. The validation study was conducted in a unique setting and indicated that the tool is valid for use by adults in Chile.

  14. [Habitat suitability index of larval Japanese Halfbeak (Hyporhamphus sajori) in Bohai Sea based on geographically weighted regression.

    PubMed

    Zhao, Yang; Zhang, Xue Qing; Bian, Xiao Dong

    2018-01-01

    To investigate the early supplementary processes of fishre sources in the Bohai Sea, the geographically weighted regression (GWR) was introduced to the habitat suitability index (HSI) model. The Bohai Sea larval Japanese Halfbeak HSI GWR model was established with four environmental variables, including sea surface temperature (SST), sea surface salinity (SSS), water depth (DEP), and chlorophyll a concentration (Chl a). Results of the simulation showed that the four variables had different performances in August 2015. SST and Chl a were global variables, and had little impacts on HSI, with the regression coefficients of -0.027 and 0.006, respectively. SSS and DEP were local variables, and had larger impacts on HSI, while the average values of absolute values of their regression coefficients were 0.075 and 0.129, respectively. In the central Bohai Sea, SSS showed a negative correlation with HSI, and the most negative correlation coefficient was -0.3. In contrast, SSS was correlated positively but weakly with HSI in the three bays of Bohai Sea, and the largest correlation coefficient was 0.1. In particular, DEP and HSI were negatively correlated in the entire Bohai Sea, while they were more negatively correlated in the three bays of Bohai than in the central Bohai Sea, and the most negative correlation coefficient was -0.16 in the three bays. The Poisson regression coefficient of the HSI GWR model was 0.705, consistent with field measurements. Therefore, it could provide a new method for the research on fish habitats in the future.

  15. Psychometric properties of the modified RESIDE physical activity questionnaire among low-income overweight women.

    PubMed

    Jones, Sydney A; Evenson, Kelly R; Johnston, Larry F; Trost, Stewart G; Samuel-Hodge, Carmen; Jewell, David A; Kraschnewski, Jennifer L; Keyserling, Thomas C

    2015-01-01

    This study explored the criterion-related validity and test-retest reliability of the modified RESIDential Environment physical activity questionnaire and whether the instrument's validity varied by body mass index, education, race/ethnicity, or employment status. Validation study using baseline data collected for randomized trial of a weight loss intervention. Participants recruited from health departments wore an ActiGraph accelerometer and self-reported non-occupational walking, moderate and vigorous physical activity on the modified RESIDential Environment questionnaire. We assessed validity (n=152) using Spearman correlation coefficients, and reliability (n=57) using intraclass correlation coefficients. When compared to steps, moderate physical activity, and bouts of moderate/vigorous physical activity measured by accelerometer, these questionnaire measures showed fair evidence for validity: recreational walking (Spearman correlation coefficients 0.23-0.36), total walking (Spearman correlation coefficients 0.24-0.37), and total moderate physical activity (Spearman correlation coefficients 0.18-0.36). Correlations for self-reported walking and moderate physical activity were higher among unemployed participants and women with lower body mass indices. Generally no other variability in the validity of the instrument was found. Evidence for reliability of RESIDential Environment measures of recreational walking, total walking, and total moderate physical activity was substantial (intraclass correlation coefficients 0.56-0.68). Evidence for questionnaire validity and reliability varied by activity domain and was strongest for walking measures. The questionnaire may capture physical activity less accurately among women with higher body mass indices and employed participants. Capturing occupational activity, specifically walking at work, may improve questionnaire validity. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  16. Prediction of soil frost penetration depth in northwest of Iran using air freezing indices

    NASA Astrophysics Data System (ADS)

    Mohammadi, H.; Moghbel, M.; Ranjbar, F.

    2016-11-01

    Information about soil frost penetration depth can be effective in finding appropriate solutions to reduce the agricultural crop damage, transportations, and building facilities. Amongst proper methods to achieve this information are the statistical and empirical models capable of estimating soil frost penetration depth. Therefore, the main objective of this research is to calculate soil frost penetration depth in northwest of Iran during the year 2007-2008 to validate two different models accuracy. To do so, the relationship between air and soil temperature in different depths (5-10-20-30-50-100 cm) at three times of the day (3, 9, and 15 GMT) for 14 weather stations over 7 provinces was analyzed using linear regression. Then, two different air freezing indices (AFIs) including Norwegian and Finn AFI was implemented. Finally, the frost penetration depth was calculated by McKeown method and the accuracy of models determined by actual soil frost penetration depth. The results demonstrated that there is a significant correlation between air and soil depth temperature in all studied stations up to the 30 cm under the surface. Also, according to the results, Norwegian index can be effectively used for determination of soil frost depth penetration and the correlation coefficient between actual and estimated soil frost penetration depth is r = 0.92 while the Finn index overestimates the frost depth in all stations with correlation coefficient r = 0.70.

  17. Effect of n-octanol in the mobile phase on lipophilicity determination by reversed-phase high-performance liquid chromatography on a modified silica column.

    PubMed

    Benhaim, Deborah; Grushka, Eli

    2008-10-31

    In this study, we show that the addition of n-octanol to the mobile phase improves the chromatographic determination of lipophilicity parameters of xenobiotics (neutral solutes, acidic, neutral and basic drugs) on a Phenomenex Gemini C18 column. The Gemini C18 column is a new generation hybrid silica-based column with an extended pH range capability. The wide pH range (2-12) afforded the examination of basic drugs and acidic drugs in their neutral form. Extrapolated retention factor values, [Formula: see text] , obtained on the above column with the n-octanol-modified mobile phase were very well correlated (1:1 correlation) with literature values of logP (logarithm of the partition coefficient in n-octanol/water) of neutral compounds and neutral drugs (69). In addition, we found good linear correlations between measured [Formula: see text] values and calculated values of the logarithm of the distribution coefficient at pH 7.0 (logD(7.0)) for ionized acidic and basic drugs (r(2)=0.95). The Gemini C18 phase was characterized using the linear solvation energy relationship (LSER) model of Abraham. The LSER system constants for the column were compared to the LSER constants of n-octanol/water extraction system using the Tanaka radar plots. The comparison shows that the two methods are nearly equivalent.

  18. Utility of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) to non-invasively diagnose burn depth in a porcine model☆

    PubMed Central

    Burmeister, David M.; Ponticorvo, Adrien; Yang, Bruce; Becerra, Sandra C.; Choi, Bernard; Durkin, Anthony J.; Christy, Robert J.

    2015-01-01

    Surgical intervention of second degree burns is often delayed because of the difficulty in visual diagnosis, which increases the risk of scarring and infection. Non-invasive metrics have shown promise in accurately assessing burn depth. Here, we examine the use of spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) for predicting burn depth. Contact burn wounds of increasing severity were created on the dorsum of a Yorkshire pig, and wounds were imaged with SFDI/LSI starting immediately after-burn and then daily for the next 4 days. In addition, on each day the burn wounds were biopsied for histological analysis of burn depth, defined by collagen coagulation, apoptosis, and adnexal/vascular necrosis. Histological results show that collagen coagulation progressed from day 0 to day 1, and then stabilized. Results of burn wound imaging using non-invasive techniques were able to produce metrics that correlate to different predictors of burn depth. Collagen coagulation and apoptosis correlated with SFDI scattering coefficient parameter ( μs′) and adnexal/vascular necrosis on the day of burn correlated with blood flow determined by LSI. Therefore, incorporation of SFDI scattering coefficient and blood flow determined by LSI may provide an algorithm for accurate assessment of the severity of burn wounds in real time. PMID:26138371

  19. Spatiotemporal Stability of Cu-ATSM and FLT Positron Emission Tomography Distributions During Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bradshaw, Tyler J.; Yip, Stephen; Jallow, Ngoneh

    2014-06-01

    Purpose: In dose painting, in which functional imaging is used to define biological targets for radiation therapy dose escalation, changes in spatial distributions of biological properties during treatment can compromise the quality of therapy. The goal of this study was to assess the spatiotemporal stability of 2 potential dose painting targets—hypoxia and proliferation—in canine tumors during radiation therapy. Methods and Materials: Twenty-two canine patients with sinonasal tumors (14 carcinoma and 8 sarcoma) were imaged before hypofractionated radiation therapy with copper(II)-diacetyl-bis(N4-methylthiosemicarbazone) (Cu-ATSM) positron emission tomography/computed tomography (PET/CT) for hypoxia and 3′-deoxy-3′-{sup 18}F-fluorothymidine (FLT) PET/CT for proliferation. The FLT scans were repeatedmore » after 2 fractions and the Cu-ATSM scans after 3 fractions. Midtreatment PET/CT images were deformably registered to pretreatment PET/CT images. Voxel-based Spearman correlation coefficients quantified the spatial stability of Cu-ATSM and FLT uptake distributions between pretreatment and midtreatment scans. Paired t tests determined significant differences between the patients' respective Cu-ATSM and FLT correlations coefficients. Standardized uptake value measures were also compared between pretreatment and midtreatment scans by use of paired t tests. Results: Spatial distributions of Cu-ATSM and FLT uptake were stable through midtreatment for both sarcomas and carcinomas: the population mean ± standard deviation in Spearman correlation coefficient was 0.88 ± 0.07 for Cu-ATSM and 0.79 ± 0.13 for FLT. The patients' Cu-ATSM correlation coefficients were significantly higher than their respective FLT correlation coefficients (P=.001). Changes in Cu-ATSM SUV measures from pretreatment to midtreatment were histology dependent: carcinomas experienced significant decreases in Cu-ATSM uptake (P<.05), whereas sarcomas did not (P>.20). Both histologies experienced significant decreases in FLT uptake (P<.05). Conclusions: Spatial distributions of Cu-ATSM were very stable after a few fractions of radiation therapy. FLT spatial distributions were generally stable early in therapy, although they were significantly less stable than Cu-ATSM distributions. Canine tumors had significantly lower proliferative activity at midtreatment than at pretreatment, and they experienced histology-dependent changes in Cu-ATSM uptake.« less

  20. Nonlinearity of the forward-backward correlation function in the model with string fusion

    NASA Astrophysics Data System (ADS)

    Vechernin, Vladimir

    2017-12-01

    The behavior of the forward-backward correlation functions and the corresponding correlation coefficients between multiplicities and transverse momenta of particles produced in high energy hadronic interactions is analyzed by analytical and MC calculations in the models with and without string fusion. The string fusion is taking into account in simplified form by introducing the lattice in the transverse plane. The results obtained with two alternative definitions of the forward-backward correlation coefficient are compared. It is shown that the nonlinearity of correlation functions increases with the width of observation windows, leading at small string density to a strong dependence of correlation coefficient value on the definition. The results of the modeling enable qualitatively to explain the experimentally observed features in the behavior of the correlation functions between multiplicities and mean transverse momenta at small and large multiplicities.

  1. Health-related quality of life in young adults in education, employment, or training: development of the Japanese version of Pediatric Quality of Life Inventory (PedsQL) Generic Core Scales Young Adult Version.

    PubMed

    Kaneko, Mei; Sato, Iori; Soejima, Takafumi; Kamibeppu, Kiyoko

    2014-09-01

    The purpose of the study is to develop a Japanese version of the Pediatric Quality of Life Inventory (PedsQL) Generic Core Scales Young Adult Version (PedsQL-YA-J) and determine the feasibility, reliability, and validity of the scales. Translation equivalence and content validity were verified using back-translation and cognitive debriefing tests. A total of 428 young adults recruited from one university, two vocational schools, or five companies completed questionnaires. We determined questionnaire feasibility, internal consistency, and test-retest reliability; checked concurrent validity against the Center for Epidemiologic Studies Depression Scale (CES-D); determined convergent and discriminant validity with the Medical Outcome Study 36-item Short Form Health Survey (SF-36); described known-groups validity with regard to subjective symptoms, illness or injury requiring regular medical visits, and depression; and verified factorial validity. All scales were internally consistent (Cronbach's coefficient alpha = 0.77-0.86); test-retest reliability was acceptable (intraclass correlation coefficient = 0.57-0.69); and all scales were concurrently valid with depression (Pearson's correlation coefficient = 0.43-0.57). The scales convergent and discriminant validity with the SF-36 and CES-D were acceptable. Evaluation of known-groups validity confirmed that the Physical Functioning scale was sensitive for subjective symptoms, the Emotional Functioning scale for depression, and the Work/School Functioning scale for illness or injury requiring regular medical visits. Exploratory factor analysis found a six-factor structure consistent with the assumed structure (cumulative proportion = 57.0%). The PedsQL-YA-J is suitable for assessing health-related quality of life in young adults in education, employment, or training, and for clinical trials and epidemiological research.

  2. Determination of flavonoids in plant material by HPLC with diode-array and electro-array detections.

    PubMed

    Mattila, P; Astola, J; Kumpulainen, J

    2000-12-01

    A high-performance liquid chromatographic (HPLC) method with in-line connected diode-array (DAD) and electro-array (EC) detection to identify and quantify 17 flavonoids in plant-derived foods is described. Catechins were extracted from the samples using ethyl acetate, and quantification of these compounds was performed with the EC detector. Other flavonoids were quantified with DAD after acid hydrolysis. The methods developed were effective for the determination of catechins and other flavonoids in plant-derived foods. Responses of the detection systems were linear within the range evaluated, 20-200 ng/injection (DAD) and 20-100 ng/injection (EC), with correlation coefficients exceeding 0.999. Coefficient of variation was under 10.5%, and recoveries of flavonoids ranged from 70 to 124%. Purity of the flavonoid peaks was confirmed by combining the spectral and voltammetric data.

  3. Two models of the sound-signal frequency dependence on the animal body size as exemplified by the ground squirrels of Eurasia (mammalia, rodentia).

    PubMed

    Nikol'skii, A A

    2017-11-01

    Dependence of the sound-signal frequency on the animal body length was studied in 14 ground squirrel species (genus Spermophilus) of Eurasia. Regression analysis of the total sample yielded a low determination coefficient (R 2 = 26%), because the total sample proved to be heterogeneous in terms of signal frequency within the dimension classes of animals. When the total sample was divided into two groups according to signal frequency, two statistically significant models (regression equations) were obtained in which signal frequency depended on the body size at high determination coefficients (R 2 = 73 and 94% versus 26% for the total sample). Thus, the problem of correlation between animal body size and the frequency of their vocal signals does not have a unique solution.

  4. Determination of Time since Death using Vitreous Humor Tryptophan.

    PubMed

    Ansari, Niha; Menon, Shobhana K

    2017-09-01

    Determination of time since death (TSD) plays very important role in forensic examination as it narrows down field of suspects and aids in deceased identification. This study utilizes the fluorescence property of vitreous humor (VH) tryptophan to determine TSD using o-phthalaldehyde (OPA). The detection limit of these fluorometric studies was found to be 8 ppb indicating sensitivity and high accuracy in TSD determination. The study was performed on selected 76 cadaver with known TSD ranging from 3 to 90 h. Excellent correlation between VH tryptophan and TSD was obtained with a coefficient of correlation R 2 = 0.9590. Results showed statistically significant increase in vitreous tryptophan with TSD up to 90 h, and the proposed method was efficaciously applied for prediction of TSD as no systematic error exist. The regression equation obtained from the study is [Trp] = 2.21 + 2.98 * TSD. © 2017 American Academy of Forensic Sciences.

  5. The relationship between the managerial skills and results of "performance evaluation "tool among nursing managers in teaching hospitals of Iran University of Medical Science.

    PubMed

    Isfahani, Haleh Mousavi; Aryankhesal, Aidin; Haghani, Hamid

    2014-09-25

    Performance of different organizations, such as hospitals is mainly influenced by their managers' performance. Nursing managers have an important role in hospital performance and their managerial skills can improve the quality of the services. Hence, the present study was conducted in order to assess the relationship between the managerial skills and the results of their performance evaluation in Teaching Hospitals of Iran University of Medical Science in 2013. The research used the cross sectional method in 2013. It was done by distributing a managerial skills assessment questionnaire, with close-ended questions in 5 choice Likert scale, among 181 managers and head nurses of hospitals of Iran university of Medical Sciences; among which 131 answered the questions. Another data collection tools was a forms to record evaluation marks from the personnel records. We used Pearson and Spearman correlation tests and SPSS for analysis and description (frequency, mean and standard deviation). Results showed that the managerial skills of the nursing mangers were fair (2.57 out of 5) and the results of the performance evaluation were in a good condition (98.44). The mangers' evaluation results and the managerial skills scores were not in a meaningful correlation (r=0.047 np=0.856). The research showed no correlation between different domains of managerial skills and the performance evaluation marks: decision making skills (r=0.074 and p=0.399), leadership (correlation coefficient 0.028 and p=0.654), motivation (correlation coefficient 0.118 and p=0.163), communication  (correlation coefficient 0.116 and p=0.122), systematic thinking  (correlation coefficient 0.028 and p=0.828), time management (correlation coefficient 0.077 and p=0.401) and strategic thinking  (correlation coefficient 0.041 and p=0.756). Lack of any correlation and relation between managers' managerial skills and their performance evaluation results shows need to a fundamental revision at managers' performance evaluation form.

  6. A Comparison between Discrimination Indices and Item-Response Theory Using the Rasch Model in a Clinical Course Written Examination of a Medical School.

    PubMed

    Park, Jong Cook; Kim, Kwang Sig

    2012-03-01

    The reliability of test is determined by each items' characteristics. Item analysis is achieved by classical test theory and item response theory. The purpose of the study was to compare the discrimination indices with item response theory using the Rasch model. Thirty-one 4th-year medical school students participated in the clinical course written examination, which included 22 A-type items and 3 R-type items. Point biserial correlation coefficient (C(pbs)) was compared to method of extreme group (D), biserial correlation coefficient (C(bs)), item-total correlation coefficient (C(it)), and corrected item-total correlation coeffcient (C(cit)). Rasch model was applied to estimate item difficulty and examinee's ability and to calculate item fit statistics using joint maximum likelihood. Explanatory power (r2) of Cpbs is decreased in the following order: C(cit) (1.00), C(it) (0.99), C(bs) (0.94), and D (0.45). The ranges of difficulty logit and standard error and ability logit and standard error were -0.82 to 0.80 and 0.37 to 0.76, -3.69 to 3.19 and 0.45 to 1.03, respectively. Item 9 and 23 have outfit > or =1.3. Student 1, 5, 7, 18, 26, 30, and 32 have fit > or =1.3. C(pbs), C(cit), and C(it) are good discrimination parameters. Rasch model can estimate item difficulty parameter and examinee's ability parameter with standard error. The fit statistics can identify bad items and unpredictable examinee's responses.

  7. Interrelationship and path coefficient analysis of yield components in F4 progenies of tef (Eragrostis tef).

    PubMed

    Debebe, Abel; Singh, Harijat; Tefera, Hailu

    2014-01-01

    This experiment was conducted at Debre Zeit and Akaki during 2004-2005 cropping season on F2-derived F4 bulk families of three crosses, viz, DZ-01-974 x DZ-01-2786, DZ-01-974 x DZ-Cr-37 and Alba x Kaye Murri. To estimate the correlations and path coefficients between yield and yield components, 63 F4 families were taken randomly from each of the three crosses. The 189 F4 families, five parents and two checks were space planted following in 14 x 14 simple lattice design. Study of associations among traits indicated that yield was positively associated with shoot biomass, harvest index, lodging index and panicle kernel weight at phenotypic level at Debre Zeit. At Akaki, yield had significant positive correlation with shoot biomass, harvest index, plant height, panicle length and panicle weight. At genotypic level, grain yield per plot exhibited positive association with harvest index, shoot biomass, lodging index and panicle kernel weight at Debre Zeit. By contrast, days to heading, days to maturity, plant height and panicle length showed negative association with yield. At Akaki, kernel yield per plot was positively correlated at genotypic level with all the traits considered where lodging index had the highest correlation followed by shoot biomass, panicle kernel weight and harvest index. Path coefficient analysis at both phenotypic and genotypic levels for both the locations suggested those shoot biomass and harvest indexes are the two important yield determining traits. These two traits might be useful in indirect selection for yield improvement in the material generated from the three crosses under consideration.

  8. Apparent Diffusion Coefficient and Dynamic Contrast-Enhanced Magnetic Resonance Imaging in Pancreatic Cancer: Characteristics and Correlation With Histopathologic Parameters.

    PubMed

    Ma, Wanling; Li, Na; Zhao, Weiwei; Ren, Jing; Wei, Mengqi; Yang, Yong; Wang, Yingmei; Fu, Xin; Zhang, Zhuoli; Larson, Andrew C; Huan, Yi

    2016-01-01

    To clarify diffusion and perfusion abnormalities and evaluate correlation between apparent diffusion coefficient (ADC), MR perfusion and histopathologic parameters of pancreatic cancer (PC). Eighteen patients with PC underwent diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Parameters of DCE-MRI and ADC of cancer and non-cancerous tissue were compared. Correlation between the rate constant that represents transfer of contrast agent from the arterial blood into the extravascular extracellular space (K, volume of the extravascular extracellular space per unit volume of tissue (Ve), and ADC of PC and histopathologic parameters were analyzed. The rate constant that represents transfer of contrast agent from the extravascular extracellular space into blood plasma, K, tissue volume fraction occupied by vascular space, and ADC of PC were significantly lower than nontumoral pancreases. Ve of PC was significantly higher than that of nontumoral pancreas. Apparent diffusion coefficient and K values of PC were negatively correlated to fibrosis content and fibroblast activation protein staining score. Fibrosis content was positively correlated to Ve. Apparent diffusion coefficient values and parameters of DCE-MRI can differentiate PC from nontumoral pancreases. There are correlations between ADC, K, Ve, and fibrosis content of PC. Fibroblast activation protein staining score of PC is negatively correlated to ADC and K. Apparent diffusion coefficient, K, and Ve may be feasible to predict prognosis of PC.

  9. Agreement Analysis: What He Said, She Said Versus You Said.

    PubMed

    Vetter, Thomas R; Schober, Patrick

    2018-06-01

    Correlation and agreement are 2 concepts that are widely applied in the medical literature and clinical practice to assess for the presence and strength of an association. However, because correlation and agreement are conceptually distinct, they require the use of different statistics. Agreement is a concept that is closely related to but fundamentally different from and often confused with correlation. The idea of agreement refers to the notion of reproducibility of clinical evaluations or biomedical measurements. The intraclass correlation coefficient is a commonly applied measure of agreement for continuous data. The intraclass correlation coefficient can be validly applied specifically to assess intrarater reliability and interrater reliability. As its name implies, the Lin concordance correlation coefficient is another measure of agreement or concordance. In undertaking a comparison of a new measurement technique with an established one, it is necessary to determine whether they agree sufficiently for the new to replace the old. Bland and Altman demonstrated that using a correlation coefficient is not appropriate for assessing the interchangeability of 2 such measurement methods. They in turn described an alternative approach, the since widely applied graphical Bland-Altman Plot, which is based on a simple estimation of the mean and standard deviation of differences between measurements by the 2 methods. In reading a medical journal article that includes the interpretation of diagnostic tests and application of diagnostic criteria, attention is conventionally focused on aspects like sensitivity, specificity, predictive values, and likelihood ratios. However, if the clinicians who interpret the test cannot agree on its interpretation and resulting typically dichotomous or binary diagnosis, the test results will be of little practical use. Such agreement between observers (interobserver agreement) about a dichotomous or binary variable is often reported as the kappa statistic. Assessing the interrater agreement between observers, in the case of ordinal variables and data, also has important biomedical applicability. Typically, this situation calls for use of the Cohen weighted kappa. Questionnaires, psychometric scales, and diagnostic tests are widespread and increasingly used by not only researchers but also clinicians in their daily practice. It is essential that these questionnaires, scales, and diagnostic tests have a high degree of agreement between observers. It is therefore vital that biomedical researchers and clinicians apply the appropriate statistical measures of agreement to assess the reproducibility and quality of these measurement instruments and decision-making processes.

  10. [Effects of different excipients on properties of Tongsaimai mixture and pellet molding].

    PubMed

    Wang, Jin; Lv, Zhiyang; Wu, Xiaoyan; Di, Liuqing; Dong, Yu; Cai, Baochang

    2011-01-01

    To study preliminarily on the relationship between properties of the mixture composed of Tongsaimai extract and different excipients and pellet molding. The multivariate regression analysis was used to investigate the correlation of different mixture and pellet molding by measuring the cohesion, liquid-plastic limit of mixture, and the powder properties of pellets. The weighted coefficients of the powder properties were determined by analytic hierarchy process combined with criteria importance through intercriteria correlation. The results showed that liquid-plastic limit seemed to be a major factor, which had positive correlation with pellet molding, while cohesion had negative correlation with pellet molding in the measured range. The physical properties of the mixture has marked influence on pellet molding.

  11. Catching ghosts with a coarse net: use and abuse of spatial sampling data in detecting synchronization

    PubMed Central

    2017-01-01

    Synchronization of population dynamics in different habitats is a frequently observed phenomenon. A common mathematical tool to reveal synchronization is the (cross)correlation coefficient between time courses of values of the population size of a given species where the population size is evaluated from spatial sampling data. The corresponding sampling net or grid is often coarse, i.e. it does not resolve all details of the spatial configuration, and the evaluation error—i.e. the difference between the true value of the population size and its estimated value—can be considerable. We show that this estimation error can make the value of the correlation coefficient very inaccurate or even irrelevant. We consider several population models to show that the value of the correlation coefficient calculated on a coarse sampling grid rarely exceeds 0.5, even if the true value is close to 1, so that the synchronization is effectively lost. We also observe ‘ghost synchronization’ when the correlation coefficient calculated on a coarse sampling grid is close to 1 but in reality the dynamics are not correlated. Finally, we suggest a simple test to check the sampling grid coarseness and hence to distinguish between the true and artifactual values of the correlation coefficient. PMID:28202589

  12. A comparison of two indices for the intraclass correlation coefficient.

    PubMed

    Shieh, Gwowen

    2012-12-01

    In the present study, we examined the behavior of two indices for measuring the intraclass correlation in the one-way random effects model: the prevailing ICC(1) (Fisher, 1938) and the corrected eta-squared (Bliese & Halverson, 1998). These two procedures differ both in their methods of estimating the variance components that define the intraclass correlation coefficient and in their performance of bias and mean squared error in the estimation of the intraclass correlation coefficient. In contrast with the natural unbiased principle used to construct ICC(1), in the present study it was analytically shown that the corrected eta-squared estimator is identical to the maximum likelihood estimator and the pairwise estimator under equal group sizes. Moreover, the empirical results obtained from the present Monte Carlo simulation study across various group structures revealed the mutual dominance relationship between their truncated versions for negative values. The corrected eta-squared estimator performs better than the ICC(1) estimator when the underlying population intraclass correlation coefficient is small. Conversely, ICC(1) has a clear advantage over the corrected eta-squared for medium and large magnitudes of population intraclass correlation coefficient. The conceptual description and numerical investigation provide guidelines to help researchers choose between the two indices for more accurate reliability analysis in multilevel research.

  13. A Modified Benedict-Webb-Rubin Equation of State for the Thermodynamic Properties of R152a (1,1-difluoroethane)

    NASA Astrophysics Data System (ADS)

    Outcalt, Stephanie L.; McLinden, Mark O.

    1996-03-01

    A modified Benedict-Webb-Rubin (MBWR) equation of state has been developed for R152a (1,1-difluoroethane). The correlation is based on a selection of available experimental thermodynamic property data. Single-phase pressure-volume-temperature (PVT), heat capacity, and sound speed data, as well as second virial coefficient, vapor pressure, and saturated liquid and saturated vapor density data, were used with multi-property linear least-squares fitting to determine the 32 adjustable coefficients of the MBWR equation. Ancillary equations representing the vapor pressure, saturated liquid and saturated vapor densities, and the ideal gas heat capacity were determined. Coefficients for the equation of state and the ancillary equations are given. Experimental data used in this work covered temperatures from 162 K to 453 K and pressures to 35 MPa. The MBWR equation established in this work may be used to predict thermodynamic properties of R152a from the triple-point temperature of 154.56 K to 500 K and for pressures up to 60 MPa except in the immediate vicinity of the critical point.

  14. Determination of reversed-phase high performance liquid chromatography based octanol-water partition coefficients for neutral and ionizable compounds: Methodology evaluation.

    PubMed

    Liang, Chao; Qiao, Jun-Qin; Lian, Hong-Zhen

    2017-12-15

    Reversed-phase liquid chromatography (RPLC) based octanol-water partition coefficient (logP) or distribution coefficient (logD) determination methods were revisited and assessed comprehensively. Classic isocratic and some gradient RPLC methods were conducted and evaluated for neutral, weak acid and basic compounds. Different lipophilicity indexes in logP or logD determination were discussed in detail, including the retention factor logk w corresponding to neat water as mobile phase extrapolated via linear solvent strength (LSS) model from isocratic runs and calculated with software from gradient runs, the chromatographic hydrophobicity index (CHI), apparent gradient capacity factor (k g ') and gradient retention time (t g ). Among the lipophilicity indexes discussed, logk w from whether isocratic or gradient elution methods best correlated with logP or logD. Therefore logk w is recommended as the preferred lipophilicity index for logP or logD determination. logk w easily calculated from methanol gradient runs might be the main candidate to replace logk w calculated from classic isocratic run as the ideal lipophilicity index. These revisited RPLC methods were not applicable for strongly ionized compounds that are hardly ion-suppressed. A previously reported imperfect ion-pair RPLC method was attempted and further explored for studying distribution coefficients (logD) of sulfonic acids that totally ionized in the mobile phase. Notably, experimental logD values of sulfonic acids were given for the first time. The IP-RPLC method provided a distinct way to explore logD values of ionized compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Correlation of MLH1 and MGMT methylation levels between peripheral blood leukocytes and colorectal tissue DNA samples in colorectal cancer patients.

    PubMed

    Li, Xia; Wang, Yibaina; Zhang, Zuoming; Yao, Xiaoping; Ge, Jie; Zhao, Yashuang

    2013-11-01

    CpG island methylation in the promoter regions of the DNA mismatch repair gene mutator L homologue 1 ( MLH1 ) and DNA repair gene O 6 -methylguanine-DNA methyltransferase ( MGMT ) genes has been shown to occur in the leukocytes of peripheral blood and colorectal tissue. However, it is unclear whether the methylation levels in the blood leukocytes and colorectal tissue are correlated. The present study analyzed and compared the levels of MGMT and MLH1 gene methylation in the leukocytes of peripheral blood and colorectal tissues obtained from patients with colorectal cancer (CRC). The methylation levels of MGMT and MLH1 were examined using methylation-sensitive high-resolution melting (MS-HRM) analysis. A total of 44 patients with CRC were selected based on the MLH1 and MGMT gene methylation levels in the leukocytes of the peripheral blood. Corresponding colorectal tumor and normal tissues were obtained from each patient and the DNA methylation levels were determined. The correlation coefficients were evaluated using Spearman's rank test. Agreement was determined by generalized κ-statistics. Spearman's rank correlation coefficients (r) for the methylation levels of the MGMT and MLH1 genes in the leukocytes of the peripheral blood and normal colorectal tissue were 0.475 and 0.362, respectively (P=0.001 and 0.016, respectively). The agreement of the MGMT and MLH1 gene methylation levels in the leukocytes of the peripheral blood and normal colorectal tissue were graded as fair and poor (κ=0.299 and 0.126, respectively). The methylation levels of MGMT and MLH1 were moderately and weakly correlated between the patient-matched leukocytes and the normal colorectal tissue, respectively. Blood-derived DNA methylation measurements may not always represent the levels of normal colorectal tissue methylation.

  16. Is bone tenderness, as measured by manual algometry, associated with vitamin D deficiency?

    PubMed Central

    Dresser, Jocelyn; MacIntyre, Mike; Chisholm, Brittney; Lawson, G.E.

    2014-01-01

    Objective: To explore the relationship between serum 25-hydroxycholecalciferol (25[OH]D3) and pressure-pain thresholds, as measured by algometer, in advance of a main study to determine whether PPT is a potentially cost-effective proxy measure of 25[OH]D3 status in the general population. Methods: The cross-sectional pilot study involved a convenience sample of twenty-two subjects (10 males, 12 females), aged 18 to 67 years. All subjects consented to three trials of pressure-pain threshold readings on both tibiae and the manubrium. Serum 25[OH]D3 levels were determined from blood samples drawn post-algometry. Results: The average pressure pain thresholds were 14.92 (±6.03), 15.07(±6.07), 11.10 (±6.68) for the left and right tibia and sternum, respectively. The stability between the measurements was very high with the interclass correlation coefficient (95% CI) calculated as 0.94 (0.62–1.00), 0.9 (0.81–1.00), 0.96(0.93–1.00). The Pearson correlation coefficients were 0.03 for the left tibia, 0.17 for the right tibia and 0.20 for the sternum, J Dresser, M MacIntyre, B Chisholm, GE Lawson showing a negligible correlation for the left and right tibia, but a low positive correlation for the sternum. Conclusion: We did not find preliminary evidence of a strong or otherwise clinically meaningful correlation between bone tenderness and manual algometry in this pilot study. Only a weak linear relationship between PPT in the sternum and serum 25[OH]D3 concentrations was found. Replication of this study is warranted in larger and more representative study populations of interest. Discussion on a number of feasibility issues is provided to inform those future studies. PMID:25202161

  17. Is bone tenderness, as measured by manual algometry, associated with vitamin D deficiency?

    PubMed

    Dresser, Jocelyn; MacIntyre, Mike; Chisholm, Brittney; Lawson, G E

    2014-09-01

    To explore the relationship between serum 25-hydroxycholecalciferol (25[OH]D3) and pressure-pain thresholds, as measured by algometer, in advance of a main study to determine whether PPT is a potentially cost-effective proxy measure of 25[OH]D3 status in the general population. The cross-sectional pilot study involved a convenience sample of twenty-two subjects (10 males, 12 females), aged 18 to 67 years. All subjects consented to three trials of pressure-pain threshold readings on both tibiae and the manubrium. Serum 25[OH]D3 levels were determined from blood samples drawn post-algometry. The average pressure pain thresholds were 14.92 (±6.03), 15.07(±6.07), 11.10 (±6.68) for the left and right tibia and sternum, respectively. The stability between the measurements was very high with the interclass correlation coefficient (95% CI) calculated as 0.94 (0.62-1.00), 0.9 (0.81-1.00), 0.96(0.93-1.00). The Pearson correlation coefficients were 0.03 for the left tibia, 0.17 for the right tibia and 0.20 for the sternum, J Dresser, M MacIntyre, B Chisholm, GE Lawson showing a negligible correlation for the left and right tibia, but a low positive correlation for the sternum. We did not find preliminary evidence of a strong or otherwise clinically meaningful correlation between bone tenderness and manual algometry in this pilot study. Only a weak linear relationship between PPT in the sternum and serum 25[OH]D3 concentrations was found. Replication of this study is warranted in larger and more representative study populations of interest. Discussion on a number of feasibility issues is provided to inform those future studies.

  18. Regression analysis and categorical agreement of fluconazole disk zone diameters and minimum inhibitory concentration by broth microdilution of clinical isolates of Candida.

    PubMed

    Aggarwal, P; Kashyap, B

    2017-06-01

    Rampant use of fluconazole in Candida infections has led to predominance of less susceptible non-albicans Candida over Candida albicans. The aim of the study was to determine if zone diameters around fluconazole disk can be used to estimate the minimum inhibitory concentration (MIC) for clinical isolates of Candida species and vice versa. Categorical agreement between the Clinical & Laboratory Standards Institute (CLSI) recommended disk diffusion and CLSI broth microdilution method was sought for. Antifungal susceptibility testing by disk diffusion and Broth microdilution was done as per CLSI document M44-S3 and CLSI document M27-S4 for Candida isolates respectively. Regression analysis correlating zone diameters to MIC value was done. Pearson's correlation coefficient was calculated to determine correlation between disk zone diameters and MICs. Candida albicans (33.3%) was clearly outnumbered by other non-albicans species predominantly Candida tropicalis (42.5%) and Candida glabrata (18.4%). Ten percent of the strains were resistant to fluconazole by disk diffusion and 13% by broth microdilution. MIC range for Candida albicans and Candida tropicalis ranged from≤0.25-64μg/ml while that of Candida glabrata ranged from≤0.25-128μg/ml. Categorical agreement between disk diffusion and broth microdilution was 86.8%. Pearson's coefficient of correlation was -0.5975 indicating moderate negative correlation between the two variables. Zone sizes can be used to estimate the MIC values, although with limited accuracy. There should be a constant effort to upgrade the guidelines in view of new clinical data, and laboratories should make an active effort to incorporate them. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  19. Detailed Analysis of the Interoccurrence Time Statistics in Seismic Activity

    NASA Astrophysics Data System (ADS)

    Tanaka, Hiroki; Aizawa, Yoji

    2017-02-01

    The interoccurrence time statistics of seismiciry is studied theoretically as well as numerically by taking into account the conditional probability and the correlations among many earthquakes in different magnitude levels. It is known so far that the interoccurrence time statistics is well approximated by the Weibull distribution, but the more detailed information about the interoccurrence times can be obtained from the analysis of the conditional probability. Firstly, we propose the Embedding Equation Theory (EET), where the conditional probability is described by two kinds of correlation coefficients; one is the magnitude correlation and the other is the inter-event time correlation. Furthermore, the scaling law of each correlation coefficient is clearly determined from the numerical data-analysis carrying out with the Preliminary Determination of Epicenter (PDE) Catalog and the Japan Meteorological Agency (JMA) Catalog. Secondly, the EET is examined to derive the magnitude dependence of the interoccurrence time statistics and the multi-fractal relation is successfully formulated. Theoretically we cannot prove the universality of the multi-fractal relation in seismic activity; nevertheless, the theoretical results well reproduce all numerical data in our analysis, where several common features or the invariant aspects are clearly observed. Especially in the case of stationary ensembles the multi-fractal relation seems to obey an invariant curve, furthermore in the case of non-stationary (moving time) ensembles for the aftershock regime the multi-fractal relation seems to satisfy a certain invariant curve at any moving times. It is emphasized that the multi-fractal relation plays an important role to unify the statistical laws of seismicity: actually the Gutenberg-Richter law and the Weibull distribution are unified in the multi-fractal relation, and some universality conjectures regarding the seismicity are briefly discussed.

  20. Estimating biomass of shrubs and forbs in central Washington Douglas-fir stands.

    Treesearch

    Craig M. Olson; Robert E. Martin

    1981-01-01

    Understory plants in closed 70-year-old even-aged Douglas-fir stands in north central Washington were destructively sampled to determine the relationship of ground cover and height to dry weight. Weight of plant material can be estimated from the product of plant height and percentage of ground cover on 50- x 100-centimeter (cm) quadrats. Correlation coefficients for...

Top