Sample records for correlation tests results

  1. Correlation between caloric and ocular vestibular evoked myogenic potential test results.

    PubMed

    Huang, Chi-Hsuan; Wang, Shou-Jen; Young, Yi-Ho

    2012-02-01

    The ocular vestibular evoked myogenic potential (o-VEMP) test results correlate significantly with caloric test results for patients with acoustic neuroma (AN), but not for patients with Meniere's disease (MD), indicating that the o-VEMP test may replace the caloric test for evaluating the vestibular nerve from which the AN arises. Conversely, the caloric, o-VEMP, and cervical VEMP (c-VEMP) tests should be performed to map lesion sites in the vestibular labyrinth. This study performed caloric, o-VEMP, and c-VEMP tests on patients with central and peripheral vestibular disorders to investigate their relationships. In all, 66 patients comprising 16 with unilateral AN and 50 with unilateral definite MD were enrolled. All patients underwent caloric, o-VEMP, and c-VEMP tests. In the AN group, the caloric test identified canal paresis and caloric areflexia in 10 ears, while the o-VEMP and c-VEMP tests identified abnormal (absent or delayed) responses in 12 and 11 ears, respectively. A significant correlation existed between caloric and o-VEMP test results, but not between caloric and c-VEMP test results, or between o-VEMP and c-VEMP test results. For the MD group, abnormal caloric, o-VEMP, and c-VEMP test results were obtained for 24%, 44%, and 38% of hydropic ears, respectively. No correlation existed between any two test results.

  2. Dynamic test/analysis correlation using reduced analytical models

    NASA Technical Reports Server (NTRS)

    Mcgowan, Paul E.; Angelucci, A. Filippo; Javeed, Mehzad

    1992-01-01

    Test/analysis correlation is an important aspect of the verification of analysis models which are used to predict on-orbit response characteristics of large space structures. This paper presents results of a study using reduced analysis models for performing dynamic test/analysis correlation. The reduced test-analysis model (TAM) has the same number and orientation of DOF as the test measurements. Two reduction methods, static (Guyan) reduction and the Improved Reduced System (IRS) reduction, are applied to the test/analysis correlation of a laboratory truss structure. Simulated test results and modal test data are used to examine the performance of each method. It is shown that selection of DOF to be retained in the TAM is critical when large structural masses are involved. In addition, the use of modal test results may provide difficulties in TAM accuracy even if a large number of DOF are retained in the TAM.

  3. Correlation between the dizziness handicap inventory and balance performance during the acute phase of unilateral vestibulopathy.

    PubMed

    Son, Eun Jin; Lee, Dong-Hee; Oh, Jeong-Hoon; Seo, Jae-Hyun; Jeon, Eun-Ju

    2015-01-01

    The dizziness handicap inventory (DHI) is widely used to evaluate self-perceived handicap due to dizziness, and is known to correlate with vestibular function tests in chronic dizziness. However, whether DHI reflects subjective symptoms during the acute phase has not been studied. This study aims to investigate the correlations of subjective and objective measurements to highlight parameters that reflect the severity of dizziness during the first week of acute unilateral vestibulopathy. Thirty-seven patients with acute unilateral vestibulopathy were examined. Patients' subjective perceptions of dizziness were measured using the DHI, Vertigo Visual Analog Scale (VVAS), Disability Scale (DS), and Activity-Specific Balance Scale (ABC). Additionally, the oculomotor tests, Romberg and sharpened Romberg tests, functional reach test, and dynamic visual acuity tests were performed. The correlation between the DHI and other tests was evaluated. DHI-total scores exhibited a moderately positive correlation with VVAS and DS, and a moderately negative correlation with ABC. However, DHI-total score did not correlate with results of the Romberg, sharpened Romberg, or functional reach tests. When compared among four groups divided according to DHI scores, VVAS and DS scores exhibited statistically significant differences, but no significant differences were detected for other test results. Our findings revealed that the DHI correlated significantly with self-perceived symptoms measured by VVAS and DS, but not ABC. There was no significant correlation with other balance function tests during the first week of acute vestibulopathy. The results suggest that DHI, VVAS and DS may be more useful to measure the severity of acute dizziness symptoms. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. The art and science of rotary wing data correlation

    NASA Technical Reports Server (NTRS)

    Drees, J. M.

    1976-01-01

    This paper presents an overview of the correlation of helicopter rotor performance and loads data from various tests and analyses. Information is included from U.S. Army-sponsored tests conducted by Bell Helicopter Company for free-flight full-scale tests in the NASA-Ames 40 x 80 wind tunnel, one-fifth scale tests in the NASA-Langley Transonic Dynamics Tunnel, and small-scale tests of a rotor in air. These test data are compared with each other, where appropriate, and with calculated results. Typical examples illustrate the state of the art for correlation and indicate anomalies encountered. It is concluded that a procedure using theoretical analyses to aid in interpretation and evaluation of test results is essential to developing a science of correlation.

  5. Correlation between subjective and objective hearing tests after unilateral and bilateral cochlear implantation.

    PubMed

    Ramakers, Geerte G J; Smulders, Yvette E; van Zon, Alice; Van Zanten, Gijsbert A; Grolman, Wilko; Stegeman, Inge

    2017-01-01

    There are many methods for assessing hearing performance after cochlear implantation. Standard evaluations often encompass objective hearing tests only, while patients' subjective experiences gain importance in today's healthcare. The aim of the current study was to analyze the correlation between subjective (self-reported questionnaires) and objective (speech perception and localization) hearing test results in adult cochlear implant (CI) users. Secondary, the correlation between subjective and objective hearing tests was compared between bilateral and unilateral CI patients. Data for this study were prospectively collected as part of a multicentre randomized controlled trial. Thirty-eight postlingually deafened adult patients were randomly allocated to receive either unilateral ( n  = 19) or bilateral ( n  = 19) cochlear implantation. We used data gathered after one year of follow-up. We studied the correlation between objectively measured speech perception and localization skills on the one hand and related domains of the Speech, Spatial and Qualities of Hearing Scale (SSQ) and Nijmegen Cochlear Implant Questionnaire (NCIQ) on the other hand. We also compared these correlations between unilateral and bilateral CI users. We found significant weak to moderate negative correlations between the subjective test results (speech domain of the SSQ and the advanced speech perception domain of the NCIQ) and the related objective speech perception in noise test results ( r  = -0.33 to -0.48). A significant moderate correlation was found between the subjective test results (spatial domain of the SSQ) and the related objective localization test results ( r  = 0.59). The correlations in the group of bilateral CI patients ( r  = -0.28 to -0.54) did not differ significantly from the correlations in the group of unilateral CI patients ( r  = 0.15 to -0.40). Current objective tests do not fully reflect subjective everyday listening situations. This study elucidates the importance and necessity of questionnaires in the evaluation of cochlear implantation. Therefore, it is advised to evaluate both objective and subjective tests in CI patients on a regular basis. This trial was registered on March 11, 2009 in the Dutch Trial Register. Trial registration number: NTR1722.

  6. Risk of false decision on conformity of a multicomponent material when test results of the components' content are correlated.

    PubMed

    Kuselman, Ilya; Pennecchi, Francesca R; da Silva, Ricardo J N B; Hibbert, D Brynn

    2017-11-01

    The probability of a false decision on conformity of a multicomponent material due to measurement uncertainty is discussed when test results are correlated. Specification limits of the components' content of such a material generate a multivariate specification interval/domain. When true values of components' content and corresponding test results are modelled by multivariate distributions (e.g. by multivariate normal distributions), a total global risk of a false decision on the material conformity can be evaluated based on calculation of integrals of their joint probability density function. No transformation of the raw data is required for that. A total specific risk can be evaluated as the joint posterior cumulative function of true values of a specific batch or lot lying outside the multivariate specification domain, when the vector of test results, obtained for the lot, is inside this domain. It was shown, using a case study of four components under control in a drug, that the correlation influence on the risk value is not easily predictable. To assess this influence, the evaluated total risk values were compared with those calculated for independent test results and also with those assuming much stronger correlation than that observed. While the observed statistically significant correlation did not lead to a visible difference in the total risk values in comparison to the independent test results, the stronger correlation among the variables caused either the total risk decreasing or its increasing, depending on the actual values of the test results. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Relationships between Dietary Intake and Cognitive Function in Healthy Korean Children and Adolescents

    PubMed Central

    Kim, Jin Young; Kang, Seung Wan

    2017-01-01

    Background It has long been theorized that a relatively robust dietary intake impacts cognitive function. The aim of the study was to explore dietary intake and cognitive function in healthy Korean children and adolescents. Methods Three hundred and seventeen healthy children with no previous diagnosis of neurologic or psychiatric disorders were evaluated (167 girls and 150 boys with a mean age of 11.8 ± 3.3 years). Analysis indicators including food frequency questionnaires (FFQs) consisting of 76 items and neurocognitive tests including symbol digit modalities (SDMT), verbal memory, visual memory, shift attention, reasoning, and digit span (forward and backward) tests were observed and recorded. Results The standard deviation in reaction time was significantly shorter in girls than in boys (p < 0.05). Verbal memory and SDMT percentile results were significantly higher in girls than in boys (p < 0.05). Vitamin C and potassium intake showed positive correlation with SDMT results (p < 0.05). Vitamin B1 intake showed positive correlation with the results of digit span forward tasks and SDMT (p < 0.01). Vitamin B6 intake showed positive correlation with the results of digit span forward tasks (p < 0.01). The consumption of noodles showed negative correlation with verbal memory, SDMT, shift attention, and reasoning test results (p < 0.05). The consumption of fast food showed negative correlation with SDMT and reasoning test results (p < 0.05). The consumption of Coca-Cola showed negative correlation with the results of verbal memory tests (p < 0.05). The consumption of mushrooms showed positive correlation with visual memory and reasoning test results (p < 0.05). The consumption of nuts showed positive correlation with SDMT results (p < 0.01). Omission errors were negatively correlated with the intake of protein, vitamin B1, vitamin B2, niacin, and vitamin B6 (p < 0.05), as well as with vitamin D and zinc intake (p < 0.01). Reaction time showed positive correlation with caffeine intake (p < 0.05). Omission errors were positively correlated with the consumption of rice and ramyeon (p < 0.01). Reaction time showed positive correlation with the consumption of snacks (p < 0.05). Standard deviations in reaction times showed positive correlation with the consumption of rice (p < 0.01), snacks, and chocolate (p < 0.05). Omission errors were negatively correlated with the consumption of rice with mixed grains (p < 0.01) and eggs (p < 0.05). Conclusion The relationship between dietary intake and cognitive function is generally better observed in girls than in boys. The consumption of healthy foods is correlated with good cognitive function. These results suggest that diet is closely related to cognitive function, even in healthy children and adolescents. PMID:28261556

  8. A study of correlations between crude oil spot and futures markets: A rolling sample test

    NASA Astrophysics Data System (ADS)

    Liu, Li; Wan, Jieqiu

    2011-10-01

    In this article, we investigate the asymmetries of exceedance correlations and cross-correlations between West Texas Intermediate (WTI) spot and futures markets. First, employing the test statistic proposed by Hong et al. [Asymmetries in stock returns: statistical tests and economic evaluation, Review of Financial Studies 20 (2007) 1547-1581], we find that the exceedance correlations were overall symmetric. However, the results from rolling windows show that some occasional events could induce the significant asymmetries of the exceedance correlations. Second, employing the test statistic proposed by Podobnik et al. [Quantifying cross-correlations using local and global detrending approaches, European Physics Journal B 71 (2009) 243-250], we find that the cross-correlations were significant even for large lagged orders. Using the detrended cross-correlation analysis proposed by Podobnik and Stanley [Detrended cross-correlation analysis: a new method for analyzing two nonstationary time series, Physics Review Letters 100 (2008) 084102], we find that the cross-correlations were weakly persistent and were stronger between spot and futures contract with larger maturity. Our results from rolling sample test also show the apparent effects of the exogenous events. Additionally, we have some relevant discussions on the obtained evidence.

  9. Correlation between bithermal caloric test results and vestibular evoked myogenic potentials (VEMPs) in normal subjects.

    PubMed

    Andrade, Isabel Vaamonde Sanchez; Santos-Perez, Sofia; Diz, Pilar Gayoso; Caballero, Torcuato Labella; Soto-Varela, Andrés

    2013-05-01

    Bithermal caloric testing and vestibular evoked myogenic potentials (VEMPs) are both diagnostic tools for the study of the vestibular system. The first tests the horizontal semicircular canal and the second evaluates the saccule and lower vestibular nerve. The results of these two tests can therefore be expected to be correlated. The aim of this study was to compare bithermal caloric test results with VEMP records in normal subjects to verify whether they are correlated. A prospective study was conducted in 60 healthy subjects (30 men and 30 women) who underwent otoscopy, pure tone audiometry, bithermal caloric testing and VEMPs. From the caloric test, we assessed the presence of possible vestibular hypofunction, whether there was directional preponderance and reflectivity of each ear (all based on both slow phase velocity and nystagmus frequency). The analysed VEMPs variables were: p1 and n1 latency, corrected amplitude, interaural p1 latency difference and p1 interaural amplitude asymmetry. We compared the reflectivity, hypofunction and directional preponderance of the caloric tests with the corrected amplitudes and amplitude asymmetries of the VEMPs. No correlations were found in the different comparisons between bithermal caloric testing results and VEMPs except for a weak correlation (p = 0.039) when comparing preponderance based on the number of nystagmus in the caloric test and amplitude asymmetry with 99 dB tone burst in the VEMPs test. The results indicate that the two diagnostic tests are not comparable, so one of them cannot replace the other, but the use of both increases diagnostic success in some conditions.

  10. Relationships between Dietary Intake and Cognitive Function in Healthy Korean Children and Adolescents.

    PubMed

    Kim, Jin Young; Kang, Seung Wan

    2017-01-01

    It has long been theorized that a relatively robust dietary intake impacts cognitive function. The aim of the study was to explore dietary intake and cognitive function in healthy Korean children and adolescents. Three hundred and seventeen healthy children with no previous diagnosis of neurologic or psychiatric disorders were evaluated (167 girls and 150 boys with a mean age of 11.8 ± 3.3 years). Analysis indicators including food frequency questionnaires (FFQs) consisting of 76 items and neurocognitive tests including symbol digit modalities (SDMT), verbal memory, visual memory, shift attention, reasoning, and digit span (forward and backward) tests were observed and recorded. The standard deviation in reaction time was significantly shorter in girls than in boys (p < 0.05). Verbal memory and SDMT percentile results were significantly higher in girls than in boys (p < 0.05). Vitamin C and potassium intake showed positive correlation with SDMT results (p < 0.05). Vitamin B1 intake showed positive correlation with the results of digit span forward tasks and SDMT (p < 0.01). Vitamin B6 intake showed positive correlation with the results of digit span forward tasks (p < 0.01). The consumption of noodles showed negative correlation with verbal memory, SDMT, shift attention, and reasoning test results (p < 0.05). The consumption of fast food showed negative correlation with SDMT and reasoning test results (p < 0.05). The consumption of Coca-Cola showed negative correlation with the results of verbal memory tests (p < 0.05). The consumption of mushrooms showed positive correlation with visual memory and reasoning test results (p < 0.05). The consumption of nuts showed positive correlation with SDMT results (p < 0.01). Omission errors were negatively correlated with the intake of protein, vitamin B1, vitamin B2, niacin, and vitamin B6 (p < 0.05), as well as with vitamin D and zinc intake (p < 0.01). Reaction time showed positive correlation with caffeine intake (p < 0.05). Omission errors were positively correlated with the consumption of rice and ramyeon (p < 0.01). Reaction time showed positive correlation with the consumption of snacks (p < 0.05). Standard deviations in reaction times showed positive correlation with the consumption of rice (p < 0.01), snacks, and chocolate (p < 0.05). Omission errors were negatively correlated with the consumption of rice with mixed grains (p < 0.01) and eggs (p < 0.05). The relationship between dietary intake and cognitive function is generally better observed in girls than in boys. The consumption of healthy foods is correlated with good cognitive function. These results suggest that diet is closely related to cognitive function, even in healthy children and adolescents.

  11. TACT: A Set of MSC/PATRAN- and MSC/NASTRAN- based Modal Correlation Tools

    NASA Technical Reports Server (NTRS)

    Marlowe, Jill M.; Dixon, Genevieve D.

    1998-01-01

    This paper describes the functionality and demonstrates the utility of the Test Analysis Correlation Tools (TACT), a suite of MSC/PATRAN Command Language (PCL) tools which automate the process of correlating finite element models to modal survey test data. The initial release of TACT provides a basic yet complete set of tools for performing correlation totally inside the PATRAN/NASTRAN environment. Features include a step-by-step menu structure, pre-test accelerometer set evaluation and selection, analysis and test result export/import in Universal File Format, calculation of frequency percent difference and cross-orthogonality correlation results using NASTRAN, creation and manipulation of mode pairs, and five different ways of viewing synchronized animations of analysis and test modal results. For the PATRAN-based analyst, TACT eliminates the repetitive, time-consuming and error-prone steps associated with transferring finite element data to a third-party modal correlation package, which allows the analyst to spend more time on the more challenging task of model updating. The usefulness of this software is presented using a case history, the correlation for a NASA Langley Research Center (LaRC) low aspect ratio research wind tunnel model. To demonstrate the improvements that TACT offers the MSC/PATRAN- and MSC/DIASTRAN- based structural analysis community, a comparison of the modal correlation process using TACT within PATRAN versus external third-party modal correlation packages is presented.

  12. Statistical correlation of structural mode shapes from test measurements and NASTRAN analytical values

    NASA Technical Reports Server (NTRS)

    Purves, L.; Strang, R. F.; Dube, M. P.; Alea, P.; Ferragut, N.; Hershfeld, D.

    1983-01-01

    The software and procedures of a system of programs used to generate a report of the statistical correlation between NASTRAN modal analysis results and physical tests results from modal surveys are described. Topics discussed include: a mathematical description of statistical correlation, a user's guide for generating a statistical correlation report, a programmer's guide describing the organization and functions of individual programs leading to a statistical correlation report, and a set of examples including complete listings of programs, and input and output data.

  13. Utility of Urinary Protein-Creatinine Ratio and Protein Content in a 24-Hour Urine Collection in Systemic Lupus Erythematosus: A Systematic Review and Meta-Analysis.

    PubMed

    Medina-Rosas, Jorge; Yap, Kristy S; Anderson, Melanie; Su, Jiandong; Touma, Zahi

    2016-09-01

    To systematically review literature on the utility of spot urinary protein-creatinine ratio (PCR) as a screening test for proteinuria and its ability to accurately measure proteinuria compared with 24-hour urine collection (24H-P) in patients with systemic lupus erythematosus (SLE). We conducted a literature search (1900-2015) for articles comparing PCR and 24H-P in SLE patients in the databases Medline, Web of Science, and Embase. Included studies and their results were critically appraised and analyzed. Thirteen studies (1,001 patients; 84.01% women) were included. Ten studies reported on Pearson's correlation (range 0.67-0.94), and 3 studies reported on Spearman's correlation (range 0.78-1.00). The meta-analysis of studies with Pearson's correlation showed a high overall correlation of 0.80 between 24H-P and PCR, yet with high heterogeneity (I(2)  = 97.2%). Correlation analysis is not sufficient to evaluate the utility of a new test against the gold standard test, and analysis on agreement is required. Seven studies reported on agreement: 3 studies analyzed concordance correlation coefficient (0.48-0.94), 3 analyzed intraclass correlation coefficient (0.66-0.95), and 1 analyzed kappa coefficient (0.58). These results confirmed that the agreement between 24H-P and PCR was inappropriate. Three studies included Bland-Altman plots, and the results also demonstrated poor agreement between both tests. The PCR has a utility as a screening test for proteinuria in SLE patients. The studies' results of 24H-P and PCR showed poor agreement between both tests, signifying that PCR should not be a substitute for the gold standard test (24H-P) to accurately measure proteinuria. © 2016, American College of Rheumatology.

  14. Development of Test-Analysis Models (TAM) for correlation of dynamic test and analysis results

    NASA Technical Reports Server (NTRS)

    Angelucci, Filippo; Javeed, Mehzad; Mcgowan, Paul

    1992-01-01

    The primary objective of structural analysis of aerospace applications is to obtain a verified finite element model (FEM). The verified FEM can be used for loads analysis, evaluate structural modifications, or design control systems. Verification of the FEM is generally obtained as the result of correlating test and FEM models. A test analysis model (TAM) is very useful in the correlation process. A TAM is essentially a FEM reduced to the size of the test model, which attempts to preserve the dynamic characteristics of the original FEM in the analysis range of interest. Numerous methods for generating TAMs have been developed in the literature. The major emphasis of this paper is a description of the procedures necessary for creation of the TAM and the correlation of the reduced models with the FEM or the test results. Herein, three methods are discussed, namely Guyan, Improved Reduced System (IRS), and Hybrid. Also included are the procedures for performing these analyses using MSC/NASTRAN. Finally, application of the TAM process is demonstrated with an experimental test configuration of a ten bay cantilevered truss structure.

  15. Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome.

    PubMed

    Heintze, Siegward D

    2007-01-01

    An accepted principle in restorative dentistry states that restorations should be placed with the best marginal quality possible to avoid postoperative sensitivity, marginal discoloration, and secondary caries. Different laboratory methods claim to predict the clinical performance of restorative materials, for example, tests of bond strength and microleakage and gap analysis. The purpose of this review was twofold: (1) find studies that correlated the results of bond strength tests with either microleakage or gap analysis for the same materials, and (2) find studies that correlated the results of microleakage and/or gaps with the clinical parameters for the same materials. Furthermore, influencing factors on the results of the laboratory tests were reviewed and assessed. For the first question, searches for studies were conducted in the MEDLINE database and IADR/AADR abtracts online with specific search and inclusion criteria. The outcome for each study was assessed on the basis of the statistical test applied in the study, and finally the number of studies with or without correlation was compiled. For the second question, results of the quantitative marginal analysis of Class V restorations published by the University of Zürich with the same test protocol and prospective clinical trials were searched that investigated the same materials for at least 2 years in Class V cavities. Pearson correlation coefficients were calculated for pooled data of materials and clinical outcome parameters such as retention loss, marginal discoloration, marginal integrity, and secondary caries. For the correlation of dye penetration and clinical outcome, studies on Class V restorations published by the same research institute were searched in MEDLINE that examined the same adhesive systems as the selected clinical trials. For the correlation bond strength/microleakage, 30 studies were included into the review, and for the correlation bond strength/gap analysis 18 studies. For both topics, about 80% of the studies revealed that there was no correlation between the two methods. For the correlation quantitative marginal analysis/clinical outcome, data were compared to the clinical outcome of 11 selected clinical studies. In only 2 out of the 11 studies (18%) did the clinical outcome match the prognosis based on the laboratory tests; the remaining studies did not show any correlation. When pooling data on 20 adhesive systems, no correlation was found between the percentage of continuous margin of restorations placed in extracted premolars and the percentage of teeth that showed no retention loss in clinical studies, no discoloured margins, acceptable margins, or absence of secondary caries. With regard to the correlation of dye penetration and clinical studies, no sufficient number of studies was found that matched the inclusion criteria. However, literature data suggest that there is no correlation between microleakage data as measured in the laboratory and clinical parameters. The results of bond strength tests did not correlate with laboratory tests that evaluated the marginal seal of restorations such as microleakage or gap analysis. The quantitative marginal analysis of Class V fillings in the laboratory was unable to predict the performance of the same materials in vivo. Therefore, microleakage tests or the quantitative marginal analysis should be abandoned and research should focus on laboratory tests that are validated with regard to their ability to satisfactorily predict the clinical performance of restorative materials.

  16. Neural Basis of Cognitive Assessment in Alzheimer Disease, Amnestic Mild Cognitive Impairment, and Subjective Memory Complaints.

    PubMed

    Matías-Guiu, Jordi A; Cabrera-Martín, María Nieves; Valles-Salgado, María; Pérez-Pérez, Alicia; Rognoni, Teresa; Moreno-Ramos, Teresa; Carreras, José Luis; Matías-Guiu, Jorge

    2017-07-01

    Interpreting cognitive tests is often challenging. The same test frequently examines multiple cognitive functions, and the functional and anatomical basis underlying test performance is unknown in many cases. This study analyses the correlation of different neuropsychological test results with brain metabolism in a series of patients evaluated for suspected Alzheimer disease. 20 healthy controls and 80 patients consulting for memory loss were included, in which cognitive study and 18 F-fluorodeoxyglucose PET were performed. Patients were categorized according to Reisberg's Global Deterioration Scale. Voxel-based analysis was used to determine correlations between brain metabolism and performance on the following tests: Free and Cued Selective Reminding Test (FCSRT), Boston Naming Test (BNT), Trail Making Test, Rey-Osterrieth Complex Figure test, Visual Object and Space Perception Battery (VOSP), and Tower of London (ToL) test. Mean age in the patient group was 73.9 ± 10.6 years, and 47 patients were women (58.7%). FCSRT findings were positively correlated with metabolism in the medial and anterior temporal region bilaterally, the left precuneus, and posterior cingulate. BNT results were correlated with metabolism in the middle temporal, superior, fusiform, and frontal medial gyri bilaterally. VOSP results were related to the occipital and parietotemporal regions bilaterally. ToL scores were correlated to metabolism in the right temporoparietal and frontal regions. These results suggest that different areas of the brain are involved in the processes required to complete different cognitive tests. Ascertaining the functional basis underlying these tests may prove helpful for understanding and interpreting them. Copyright © 2017 American Association for Geriatric Psychiatry. Published by Elsevier Inc. All rights reserved.

  17. Correlation of finite element free vibration predictions using random vibration test data. M.S. Thesis - Cleveland State Univ.

    NASA Technical Reports Server (NTRS)

    Chambers, Jeffrey A.

    1994-01-01

    Finite element analysis is regularly used during the engineering cycle of mechanical systems to predict the response to static, thermal, and dynamic loads. The finite element model (FEM) used to represent the system is often correlated with physical test results to determine the validity of analytical results provided. Results from dynamic testing provide one means for performing this correlation. One of the most common methods of measuring accuracy is by classical modal testing, whereby vibratory mode shapes are compared to mode shapes provided by finite element analysis. The degree of correlation between the test and analytical mode shapes can be shown mathematically using the cross orthogonality check. A great deal of time and effort can be exhausted in generating the set of test acquired mode shapes needed for the cross orthogonality check. In most situations response data from vibration tests are digitally processed to generate the mode shapes from a combination of modal parameters, forcing functions, and recorded response data. An alternate method is proposed in which the same correlation of analytical and test acquired mode shapes can be achieved without conducting the modal survey. Instead a procedure is detailed in which a minimum of test information, specifically the acceleration response data from a random vibration test, is used to generate a set of equivalent local accelerations to be applied to the reduced analytical model at discrete points corresponding to the test measurement locations. The static solution of the analytical model then produces a set of deformations that once normalized can be used to represent the test acquired mode shapes in the cross orthogonality relation. The method proposed has been shown to provide accurate results for both a simple analytical model as well as a complex space flight structure.

  18. Accelerated Dynamic Corrosion Test Method Development

    DTIC Science & Technology

    test method has poor correlation to outdoor exposures, particularly for non-chromate primers. As a result, more realistic cyclic environmental...exposures have been developed to more closely resemble actual atmospheric corrosion damage. Several existing tests correlate well with the outdoor performance

  19. Full-scale locomotive dynamic collision testing and correlations : offset collisions between a locomotive and a covered hopper car (test 4).

    DOT National Transportation Integrated Search

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision test with rail vehicles as part of the Federal Railroad Administrations research program on improved crashworthiness of locomotive structures. ...

  20. A modified correlation between KJIC and Charpy V-notch impact energy of Chinese SA508-III steel at the upper shelf

    NASA Astrophysics Data System (ADS)

    Li, Xiangqing; Song, Yuxuan; Ding, Zhenyu; Bao, Shiyi; Gao, Zengliang

    2018-07-01

    The fracture toughness plays a significant role in the structural integrity assessment of reactor pressure vessels (RPVs) in service temperature. The Charpy V-notch (CVN) impact test is used to estimate fracture toughness (KIC or KJIC) indirectly since universal fracture toughness tests are costly, sophisticated and frequently invalid. In this study, a modified correlation which based on the typical model of KJIC-CVN at the upper shelf was established for Chinese SA508-III steel. Thereinto, the effect of test temperature (T) was directly considered in the correlation. To assess the accuracy of fracture toughness when calculating from the value of Charpy-V notch impact energy by using the modified correlation, both the Charpy-V notch impact tests and fracture toughness tests for Chinese SA508-III steel were conducted at different temperatures (100 °C, 150 °C, 200 °C, 250 °C and 320 °C). The results showed that the modified correlation exhibited the high precision for estimating fracture toughness of Chinese SA508-III steel and the relative error for tested and estimated results is within 8%, which is lower than that of other correlations.

  1. Patient-reported speech in noise difficulties and hyperacusis symptoms and correlation with test results.

    PubMed

    Spyridakou, Chrysa; Luxon, Linda M; Bamiou, Doris E

    2012-07-01

    To compare self-reported symptoms of difficulty hearing speech in noise and hyperacusis in adults with auditory processing disorders (APDs) and normal controls; and to compare self-reported symptoms to objective test results (speech in babble test, transient evoked otoacoustic emission [TEOAE] suppression test using contralateral noise). A prospective case-control pilot study. Twenty-two participants were recruited in the study: 10 patients with reported hearing difficulty, normal audiometry, and a clinical diagnosis of APD; and 12 normal age-matched controls with no reported hearing difficulty. All participants completed the validated Amsterdam Inventory for Auditory Disability questionnaire, a hyperacusis questionnaire, a speech in babble test, and a TEOAE suppression test using contralateral noise. Patients had significantly worse scores than controls in all domains of the Amsterdam Inventory questionnaire (with the exception of sound detection) and the hyperacusis questionnaire (P < .005). Patients also had worse TEOAE suppression test results in both ears than controls; however, this result was not significant after Bonferroni correction. Strong correlations were observed between self-reported symptoms of difficulty hearing speech in noise and speech in babble test results in the right ear (ρ = 0.624, P = .002), and between self-reported symptoms of hyperacusis and TEOAE suppression test results in the right ear (ρ = -0.597 P = .003). There was no significant correlation between the two tests. A strong correlation was observed between right ear speech in babble and patient-reported intelligibility of speech in noise, and right ear TEOAE suppression by contralateral noise and hyperacusis questionnaire. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  2. Using Dispersed Modes During Model Correlation

    NASA Technical Reports Server (NTRS)

    Stewart, Eric C.; Hathcock, Megan L.

    2017-01-01

    The model correlation process for the modal characteristics of a launch vehicle is well established. After a test, parameters within the nominal model are adjusted to reflect structural dynamics revealed during testing. However, a full model correlation process for a complex structure can take months of man-hours and many computational resources. If the analyst only has weeks, or even days, of time in which to correlate the nominal model to the experimental results, then the traditional correlation process is not suitable. This paper describes using model dispersions to assist the model correlation process and decrease the overall cost of the process. The process creates thousands of model dispersions from the nominal model prior to the test and then compares each of them to the test data. Using mode shape and frequency error metrics, one dispersion is selected as the best match to the test data. This dispersion is further improved by using a commercial model correlation software. In the three examples shown in this paper, this dispersion based model correlation process performs well when compared to models correlated using traditional techniques and saves time in the post-test analysis.

  3. Comparison between Standing Broad Jump test and Wingate test for assessing lower limb anaerobic power in elite sportsmen.

    PubMed

    Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P

    2017-04-01

    Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power ( r  = 0.446, p  < 0.0001) and SBJ (distance) in all sportsmen. Inter-sport correlation showed positive correlation between SBJ and peak power ( r  = 0.335, p  < 0.016) in Fencers and between SBJ, peak power ( r  = 0.686, p  < 0.002) in Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.

  4. Reliability Measure of a Clinical Test: Appreciation of Music in Cochlear Implantees (AMICI)

    PubMed Central

    Cheng, Min-Yu; Spitzer, Jaclyn B.; Shafiro, Valeriy; Sheft, Stanley; Mancuso, Dean

    2014-01-01

    Purpose The goals of this study were (1) to investigate the reliability of a clinical music perception test, Appreciation of Music in Cochlear Implantees (AMICI), and (2) examine associations between the perception of music and speech. AMICI was developed as a clinical instrument for assessing music perception in persons with cochlear implants (CIs). The test consists of four subtests: (1) music versus environmental noise discrimination, (2) musical instrument identification (closed-set), (3) musical style identification (closed-set), and (4) identification of musical pieces (open-set). To be clinically useful, it is crucial for AMICI to demonstrate high test-retest reliability, so that CI users can be assessed and retested after changes in maps or programming strategies. Research Design Thirteen CI subjects were tested with AMICI for the initial visit and retested again 10–14 days later. Two speech perception tests (consonant-nucleus-consonant [CNC] and Bamford-Kowal-Bench Speech-in-Noise [BKB-SIN]) were also administered. Data Analysis Test-retest reliability and equivalence of the test’s three forms were analyzed using paired t-tests and correlation coefficients, respectively. Correlation analysis was also conducted between results from the music and speech perception tests. Results Results showed no significant difference between test and retest (p > 0.05) with adequate power (0.9) as well as high correlations between the three forms (Forms A and B, r = 0.91; Forms A and C, r = 0.91; Forms B and C, r = 0.95). Correlation analysis showed high correlation between AMICI and BKB-SIN (r = −0.71), and moderate correlation between AMICI and CNC (r = 0.4). Conclusions The study showed AMICI is highly reliable for assessing musical perception in CI users. PMID:24384082

  5. Testing for the Presence of Correlation Changes in a Multivariate Time Series: A Permutation Based Approach.

    PubMed

    Cabrieto, Jedelyn; Tuerlinckx, Francis; Kuppens, Peter; Hunyadi, Borbála; Ceulemans, Eva

    2018-01-15

    Detecting abrupt correlation changes in multivariate time series is crucial in many application fields such as signal processing, functional neuroimaging, climate studies, and financial analysis. To detect such changes, several promising correlation change tests exist, but they may suffer from severe loss of power when there is actually more than one change point underlying the data. To deal with this drawback, we propose a permutation based significance test for Kernel Change Point (KCP) detection on the running correlations. Given a requested number of change points K, KCP divides the time series into K + 1 phases by minimizing the within-phase variance. The new permutation test looks at how the average within-phase variance decreases when K increases and compares this to the results for permuted data. The results of an extensive simulation study and applications to several real data sets show that, depending on the setting, the new test performs either at par or better than the state-of-the art significance tests for detecting the presence of correlation changes, implying that its use can be generally recommended.

  6. Input Correlations for Irradiation Creep of FeCrAl and SiC Based on In-Pile Halden Test Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terrani, K. A.; Karlsen, T. M.; Yamamoto, Yukinori

    2016-05-01

    Swelling and creep behavior of wrought FeCrAl alloys and CVD-SiC, two candidate accident tolerant fuel cladding materials, are being examined using in-pile tests at the Halden reactor. The outcome of these tests are material property correlations that are inputs into fuel performance analysis tools. The results are discussed and compared with what is available in literature from irradiation experiments in other reactors or out-of-pile tests. Specific recommendation on what correlations should be used for swelling, thermal, and irradiation creep for each material are provided in this document.

  7. Correlation of Space Shuttle Landing Performance with Post-Flight Cardiovascular Dysfunction

    NASA Technical Reports Server (NTRS)

    McCluskey, R.

    2004-01-01

    Introduction: Microgravity induces cardiovascular adaptations resulting in orthostatic intolerance on re-exposure to normal gravity. Orthostasis could interfere with performance of complex tasks during the re-entry phase of Shuttle landings. This study correlated measures of Shuttle landing performance with post-flight indicators of orthostatic intolerance. Methods: Relevant Shuttle landing performance parameters routinely recorded at touchdown by NASA included downrange and crossrange distances, airspeed, and vertical speed. Measures of cardiovascular changes were calculated from operational stand tests performed in the immediate post-flight period on mission commanders from STS-41 to STS-66. Stand test data analyzed included maximum standing heart rate, mean increase in maximum heart rate, minimum standing systolic blood pressure, and mean decrease in standing systolic blood pressure. Pearson correlation coefficients were calculated with the null hypothesis that there was no statistically significant linear correlation between stand test results and Shuttle landing performance. A correlation coefficient? 0.5 with a p<0.05 was considered significant. Results: There were no significant linear correlations between landing performance and measures of post-flight cardiovascular dysfunction. Discussion: There was no evidence that post-flight cardiovascular stand test data correlated with Shuttle landing performance. This implies that variations in landing performance were not due to space flight-induced orthostatic intolerance.

  8. Development of an unsteady aerodynamics model to improve correlation of computed blade stresses with test data

    NASA Technical Reports Server (NTRS)

    Gangwani, S. T.

    1985-01-01

    A reliable rotor aeroelastic analysis operational that correctly predicts the vibration levels for a helicopter is utilized to test various unsteady aerodynamics models with the objective of improving the correlation between test and theory. This analysis called Rotor Aeroelastic Vibration (RAVIB) computer program is based on a frequency domain forced response analysis which utilizes the transfer matrix techniques to model helicopter/rotor dynamic systems of varying degrees of complexity. The results for the AH-1G helicopter rotor were compared with the flight test data during high speed operation and they indicated a reasonably good correlation for the beamwise and chordwise blade bending moments, but for torsional moments the correlation was poor. As a result, a new aerodynamics model based on unstalled synthesized data derived from the large amplitude oscillating airfoil experiments was developed and tested.

  9. Test anxiety in medical school is unrelated to academic performance but correlates with an effort/reward imbalance

    PubMed Central

    Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte

    2017-01-01

    Purpose During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. Methods A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Results Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Conclusion Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received. PMID:28182781

  10. Evaluating resin-enamel bonds by microshear and microtensile bond strength tests: effects of composite resin

    PubMed Central

    de ANDRADE, Andrea Mello; MOURA, Sandra Kiss; REIS, Alessandra; LOGUERCIO, Alessandro Dourado; GARCIA, Eugenio Jose; GRANDE, Rosa Helena Miranda

    2010-01-01

    Objectives The aims of this study were to evaluate the effect of resin composite (Filtek Z250 and Filtek Flow Z350) and adhesive system [(Solobond Plus, Futurabond NR (VOCO) and Adper Single Bond (3M ESPE)] on the microtensile (µTBS) and microshear bond strength (µSBS) tests on enamel, and to correlate the bond strength means between them. Material and methods Thirty-six extracted human molars were sectioned to obtain two tooth halves: one for µTBS and the other one for µSBS. Adhesive systems and resin composites were applied to the enamel ground surfaces and light-cured. After storage (37ºC/24 h) specimens were stressed (0.5 mm/ min). Fracture modes were analyzed under scanning electron microscopy. The data were analyzed using two-way ANOVA and Tukey's test (α=0.05). Results The correlation between tests was estimated with Pearson's product-moment correlation statistics (α =0.05). For both tests only the main factor resin composite was statistically significant (p<0.05). The correlation test detected a positive (r=0.91) and significant (p=0.01) correlation between the tests. Conclusions The results were more influenced by the resin type than by the adhesives. Both microbond tests seem to be positive and linearly correlated and can therefore lead to similar conclusions. PMID:21308290

  11. Hot-cracking studies of Inconel 718 weld- heat-affected zones

    NASA Technical Reports Server (NTRS)

    Thompson, E. G.

    1969-01-01

    Hot ductility tests, gas-tungsten-arc fillerless fusion tests, and circle patch-weld-restraint tests were conducted on Inconel 718 to better understand and correlate the weldability /resistance to hot cracking/ of the alloy. A correlation of the test results with composition, heat-treat condition, grain size, and microstructure was made.

  12. Electric vehicle chassis dynamometer test methods at JPL and their correlation to track tests

    NASA Technical Reports Server (NTRS)

    Marte, J.; Bryant, J.

    1983-01-01

    Early in its electric vehicle (EV) test program, JPL recognized that EV test procedures were too vague and too loosely defined to permit much meaningful data to be obtained from the testing. Therefore, JPL adopted more stringent test procedures and chose the chassis dynamometer rather than the track as its principal test technique. Through the years, test procedures continued to evolve towards a methodology based on chassis dynamometers which would exhibit good correlation with track testing. Based on comparative dynamometer and track test results on the ETV-1 vehicle, the test methods discussed in this report demonstrate a means by which excellent track-to-dynamometer correlation can be obtained.

  13. Prevalence and correlates of human immunodeficiency virus testing and posttest counseling among outpatients with serious mental illness.

    PubMed

    Desai, Mayur M; Rosenheck, Robert A; Desai, Rani A

    2007-09-01

    This study examined the prevalence and correlates of receipt of human immunodeficiency virus (HIV) testing, test results, and posttest counseling among outpatients with serious mental illness at 3 public-sector facilities in Connecticut (N = 487). A substantial proportion (41.9%) reported never having been tested for HIV, including fully one-third of those who were "very afraid" of getting acquired immune deficiency syndrome. Independent correlates of HIV testing included younger age, felony criminal history, stronger therapeutic alliance with one's primary clinician, and increased drug problems and psychological distress. Of those tested, nearly all (96.5%) reported receiving the test results; however, only half (50.5%) reported receiving any posttest counseling. Independent correlates of posttest counseling included higher educational level, felony criminal history, and receipt of community-based case management services. Greater efforts are needed to increase HIV testing and counseling among persons with serious mental illness to better identify and care for HIV-positive individuals and potentially reduce future transmission of the virus in this vulnerable, at-risk population.

  14. The relation of cortisol and sex hormone levels to results of psychological, performance, IQ and memory tests in military men and women.

    PubMed

    Flegr, Jaroslav; Hampl, Richard; Černochová, Dana; Preiss, Marek; Bičíková, Marie; Sieger, Ladislav; Příplatová, Lenka; Kaňková, Šárka; Klose, Jiří

    2012-01-01

    Cortisol, along with other hormones of hypothalamo-pituitary-adrenal axis, belongs to one of the main factors influencing psychological and pathognomic factors, intelligence, and memory. The aim of our study was to review a large battery of psychological, performance, IQ and memory tests as to their relation with cortisol, testosterone and estrogen levels in groups of 100 men and 93 women who attended the Central Military Hospital in Prague for regular entrance psychological examinations for military personnel. In men, we detected positive correlations between cortisol and emotional lability, and negative correlations with impulsivity, while in women hypochondria and psychopathology were negatively correlated, and aggression measured with the Meili selective memory test had a positive relation to cortisol level. Testosterone correlated positively with emotional liability and negatively with impulsivity in men, and negatively with hypochondria and psychasteny, indirect aggression, irritability and paranoia in women. Estradiol correlated positively with psychopathology in men, and negatively with phobia. It was positively correlated with negativism in women. No clear correlation was observed between the concentration of steroid hormones and psychomotor performance or intelligence. Concentrations of steroid hormones correlate with results of several psychological tests, the sign and magnitude of these correlations, however, very often differ in military men and women.

  15. Trends in Correlation-Based Pattern Recognition and Tracking in Forward-Looking Infrared Imagery

    PubMed Central

    Alam, Mohammad S.; Bhuiyan, Sharif M. A.

    2014-01-01

    In this paper, we review the recent trends and advancements on correlation-based pattern recognition and tracking in forward-looking infrared (FLIR) imagery. In particular, we discuss matched filter-based correlation techniques for target detection and tracking which are widely used for various real time applications. We analyze and present test results involving recently reported matched filters such as the maximum average correlation height (MACH) filter and its variants, and distance classifier correlation filter (DCCF) and its variants. Test results are presented for both single/multiple target detection and tracking using various real-life FLIR image sequences. PMID:25061840

  16. Correlations of Platooning Track Test and Wind Tunnel Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lammert, Michael P.; Kelly, Kenneth J.; Yanowitz, Janet

    In this report, the National Renewable Energy Laboratory analyzed results from multiple, independent truck platooning projects to compare and contrast track test results with wind tunnel test results conducted by Lawrence Livermore National Laboratory (LLNL). Some highlights from the report include compiled data, and results from four independent SAE J1321 full-size track test campaigns that were compared to LLNL wind tunnel testing results. All platooning scenarios tested demonstrated significant fuel savings with good correlation relative to following distances, but there are still unanswered questions and clear opportunities for system optimization. NOx emissions showed improvements from NREL tests in 2014 tomore » Auburn tests in 2015 with respect to J1321 platooning track testing of Peloton system. NREL evaluated data from Volpe's Naturalistic Study of Truck Following Behavior, which showed minimal impact of naturalistic background platooning. We found significant correlation between multiple track studies, wind tunnel tests, and computational fluid dynamics, but also showed that there is more to learn regarding close formation and longer-distance effects. We also identified potential areas for further research and development, including development of advanced aerodynamic designs optimized for platooning, measurement of platoon system performance in traffic conditions, impact of vehicle lateral offsets on platooning performance, and characterization of the national potential for platooning based on fleet operational characteristics.« less

  17. Co-variation of tests commonly used in stroke rehabilitation.

    PubMed

    Langhammer, Birgitta; Stanghelle, Johan Kvalvik

    2006-12-01

    The aim of the present study was to analyse the co-variation of different tests commonly used in stroke rehabilitation, and specifically used in a recent randomized, controlled study of two different physiotherapy models in stroke rehabilitation. Correlations of the performed tests and recordings from previous work were studied. The test results from three-month, one-year and four-year follow-up were analysed in an SPSS Version 11 statistical package with Pearson and Spearman correlations. There was an expected high correlation between the motor function tests, both based on partial and total scores. The correlations between Nottingham Health Profile Part 1 and Motor Assessment Scale (MAS), Sødring Motor Evaluation Scale (SMES), the Berg Balance Scale (BBS) and Barthel Activities of Daily Living (ADL) index were low for all items except physical condition. The correlations between registered living conditions, assistive devices, recurrent stroke, motor function (MAS, SMES), ADL (Barthel ADL index) and balance (BBS) were high. The same variables showed weak or poor correlation to the Nottingham Health Profile (NHP). The co-variations of motor function tests and functional tests were high, but the co-variations of motor, functional and self-reported life-quality tests were poor. The patients rated themselves on a higher functional level in the self-reported tests than was observed objectively in the performance-based tests. A possible reason for this is that the patients may have been unaware they modified their performance to adjust for physical decline, and consequently overestimate their physical condition. This result underlines the importance of both performance-based and self-reported tests as complementary tools in a rehabilitation process.

  18. Correlation Between Subacute Sensorimotor Deficits and Brain Edema in Rats after Surgical Brain Injury.

    PubMed

    McBride, Devin W; Wang, Yuechun; Adam, Loic; Oudin, Guillaume; Louis, Jean-Sébastien; Tang, Jiping; Zhang, John H

    2016-01-01

    No matter how carefully a neurosurgical procedure is performed, it is intrinsically linked to postoperative deficits resulting in delayed healing caused by direct trauma, hemorrhage, and brain edema, termed surgical brain injury (SBI). Cerebral edema occurs several hours after SBI and is a major contributor to patient morbidity, resulting in increased postoperative care. Currently, the correlation between functional recovery and brain edema after SBI remains unknown. Here we examine the correlation between neurological function and brain water content in rats 42 h after SBI. SBI was induced in male Sprague-Dawley rats via frontal lobectomy. Twenty-four hours post-ictus animals were subjected to four neurobehavior tests: composite Garcia neuroscore, beam walking test, corner turn test, and beam balance test. Animals were then sacrificed for right-frontal brain water content measurement via the wet-dry method. Right-frontal lobe brain water content was found to significantly correlate with neurobehavioral deficits in the corner turn and beam balance tests: the number of left turns (percentage of total turns) for the corner turn test and distance traveled for the beam balance test were both inversely proportional with brain water content. No correlation was observed for the composite Garcia neuroscore or the beam walking test.

  19. Measurement of ability emotional intelligence: results for two new tests.

    PubMed

    Austin, Elizabeth J

    2010-08-01

    Emotional intelligence (EI) has attracted considerable interest amongst both individual differences researchers and those in other areas of psychology who are interested in how EI relates to criteria such as well-being and career success. Both trait (self-report) and ability EI measures have been developed; the focus of this paper is on ability EI. The associations of two new ability EI tests with psychometric intelligence, emotion perception, and the Mayer-Salovey-Caruso EI test (MSCEIT) were examined. The new EI tests were the Situational Test of Emotion Management (STEM) and the Situational Test of Emotional Understanding (STEU). Only the STEU and the MSCEIT Understanding Emotions branch were significantly correlated with psychometric intelligence, suggesting that only understanding emotions can be regarded as a candidate new intelligence component. These understanding emotions tests were also positively correlated with emotion perception tests, and STEM and STEU scores were positively correlated with MSCEIT total score and most branch scores. Neither the STEM nor the STEU were significantly correlated with trait EI tests, confirming the distinctness of trait and ability EI. Taking the present results as a starting-point, approaches to the development of new ability EI tests and models of EI are suggested.

  20. Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

    NASA Technical Reports Server (NTRS)

    Kim, Jong S.; Teti, Nicholas M.

    2015-01-01

    International Conference on Envronmental Systems (ICES), Seattle WA NCTS 20964-15. The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earths magnetosphere as a laboratory tostudy the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10-4 Pa (10-6 torr)and the surrounding temperature achieving -180 C. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperatureversus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDAFLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 C of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 C and the heater power goal is to be within 5 of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

  1. Thermal Testing and Model Correlation of the Magnetospheric Multiscale (MMS) Observatories

    NASA Technical Reports Server (NTRS)

    Kim, Jong S.; Teti, Nicholas M.

    2015-01-01

    The Magnetospheric Multiscale (MMS) mission is a Solar Terrestrial Probes mission comprising four identically instrumented spacecraft that will use Earth's magnetosphere as a laboratory to study the microphysics of three fundamental plasma processes: magnetic reconnection, energetic particle acceleration, and turbulence. This paper presents the complete thermal balance (TB) test performed on the first of four observatories to go through thermal vacuum (TV) and the minibalance testing that was performed on the subsequent observatories to provide a comparison of all four. The TV and TB tests were conducted in a thermal vacuum chamber at the Naval Research Laboratory (NRL) in Washington, D.C. with the vacuum level higher than 1.3 x 10 (sup -4) pascals (10 (sup -6) torr) and the surrounding temperature achieving -180 degrees Centigrade. Three TB test cases were performed that included hot operational science, cold operational science and a cold survival case. In addition to the three balance cases a two hour eclipse and a four hour eclipse simulation was performed during the TV test to provide additional transient data points that represent the orbit in eclipse (or Earth's shadow) The goal was to perform testing such that the flight orbital environments could be simulated as closely as possible. A thermal model correlation between the thermal analysis and the test results was completed. Over 400 1-Wire temperature sensors, 200 thermocouples and 125 flight thermistor temperature sensors recorded data during TV and TB testing. These temperature versus time profiles and their agreements with the analytical results obtained using Thermal Desktop and SINDA/FLUINT are discussed. The model correlation for the thermal mathematical model (TMM) is conducted based on the numerical analysis results and the test data. The philosophy of model correlation was to correlate the model to within 3 degrees Centigrade of the test data using the standard deviation and mean deviation error calculation. Individual temperature error goal is to be within 5 degrees Centigrade and the heater power goal is to be within 5 percent of test data. The results of the model correlation are discussed and the effect of some material and interface parameters on the temperature profiles are presented.

  2. Correlation of ground tests and analyses of a dynamically scaled Space Station model configuration

    NASA Technical Reports Server (NTRS)

    Javeed, Mehzad; Edighoffer, Harold H.; Mcgowan, Paul E.

    1993-01-01

    Verification of analytical models through correlation with ground test results of a complex space truss structure is demonstrated. A multi-component, dynamically scaled space station model configuration is the focus structure for this work. Previously established test/analysis correlation procedures are used to develop improved component analytical models. Integrated system analytical models, consisting of updated component analytical models, are compared with modal test results to establish the accuracy of system-level dynamic predictions. Design sensitivity model updating methods are shown to be effective for providing improved component analytical models. Also, the effects of component model accuracy and interface modeling fidelity on the accuracy of integrated model predictions is examined.

  3. Correlation between skin-prick testing, individual specific IgE tests, and a multiallergen IgE assay for allergy detection in patients with chronic rhinitis.

    PubMed

    Cho, Jae Hoon; Suh, Jeffrey D; Kim, Jin Kook; Hong, Seok-Chan; Park, Il-Ho; Lee, Heung-Man

    2014-01-01

    Allergy test results can differ based on the method used. The most common tests include skin-prick testing (SPT) and in vitro tests to detect allergen-specific IgE. This study was designed to assess allergy test results using SPT, individual specific IgE tests, and a multiallergen IgE assay (multiple allergen simultaneous test) in patients with chronic rhinitis and controls. One hundred forty total patients were prospectively enrolled in the study, including 100 patients with chronic rhinitis and 40 control patients without atopy. All eligible patients underwent SPT, serum analysis using individual specific IgE test, and multiple allergen simultaneous test against 10 common allergens. Allergy test results were then compared to identify correlation and interest agreement. There was an 81-97% agreement between SPT and individual specific IgE test in allergen detection and an 80-98% agreement between SPT and multiple allergen simultaneous test. Individual specific IgE test and multiple allergen simultaneous test allergy detection prevalence was generally similar to SPT in patients with chronic rhinitis. All control patients had negative SPT (0/40), but low positive results were found with both individual specific IgE test (5-12.5%) and multiple allergen simultaneous test (2.5-7.5%) to some allergens, especially cockroach, Dermatophagoides farina, and ragweed. Agreement and correlation between individual specific IgE test and multiple allergen simultaneous test were good to excellent for a majority of tested allergens. This study shows good agreement and correlation between SPT with individual specific IgE test and multiple allergen simultaneous test on a majority of the tested allergens for patients with chronic rhinitis. Comparing the two in vitro tests, individual specific IgE test agrees with SPT better than multiple allergen simultaneous test.

  4. 3D digital image correlation methods for full-field vibration measurement

    NASA Astrophysics Data System (ADS)

    Helfrick, Mark N.; Niezrecki, Christopher; Avitabile, Peter; Schmidt, Timothy

    2011-04-01

    In the area of modal test/analysis/correlation, significant effort has been expended over the past twenty years in order to make reduced models and to expand test data for correlation and eventual updating of the finite element models. This has been restricted by vibration measurements which are traditionally limited to the location of relatively few applied sensors. Advances in computers and digital imaging technology have allowed 3D digital image correlation (DIC) methods to measure the shape and deformation of a vibrating structure. This technique allows for full-field measurement of structural response, thus providing a wealth of simultaneous test data. This paper presents some preliminary results for the test/analysis/correlation of data measured using the DIC approach along with traditional accelerometers and a scanning laser vibrometer for comparison to a finite element model. The results indicate that all three approaches correlated well with the finite element model and provide validation for the DIC approach for full-field vibration measurement. Some of the advantages and limitations of the technique are presented and discussed.

  5. An Improved Correction for Range Restricted Correlations Under Extreme, Monotonic Quadratic Nonlinearity and Heteroscedasticity.

    PubMed

    Culpepper, Steven Andrew

    2016-06-01

    Standardized tests are frequently used for selection decisions, and the validation of test scores remains an important area of research. This paper builds upon prior literature about the effect of nonlinearity and heteroscedasticity on the accuracy of standard formulas for correcting correlations in restricted samples. Existing formulas for direct range restriction require three assumptions: (1) the criterion variable is missing at random; (2) a linear relationship between independent and dependent variables; and (3) constant error variance or homoscedasticity. The results in this paper demonstrate that the standard approach for correcting restricted correlations is severely biased in cases of extreme monotone quadratic nonlinearity and heteroscedasticity. This paper offers at least three significant contributions to the existing literature. First, a method from the econometrics literature is adapted to provide more accurate estimates of unrestricted correlations. Second, derivations establish bounds on the degree of bias attributed to quadratic functions under the assumption of a monotonic relationship between test scores and criterion measurements. New results are presented on the bias associated with using the standard range restriction correction formula, and the results show that the standard correction formula yields estimates of unrestricted correlations that deviate by as much as 0.2 for high to moderate selectivity. Third, Monte Carlo simulation results demonstrate that the new procedure for correcting restricted correlations provides more accurate estimates in the presence of quadratic and heteroscedastic test score and criterion relationships.

  6. Test-Retest Reliability of the Salutogenic Wellness Promotion Scale (SWPS)

    ERIC Educational Resources Information Center

    Anderson, L. M.; Moore, J. B.; Hayden, B. M.; Becker, C. M.

    2014-01-01

    Objective: This study examined the temporal stability (i.e. test-retest reliability) of the Salutogenic Wellness Promotion Scale (SWPS) using intraclass correlation coefficients (ICC). Current intraclass results were also compared to previously published interclass correlations to support the use of the intraclass method for test-retest…

  7. An enhanced methodology for spacecraft correlation activity using virtual testing tools

    NASA Astrophysics Data System (ADS)

    Remedia, Marcello; Aglietti, Guglielmo S.; Appolloni, Matteo; Cozzani, Alessandro; Kiley, Andrew

    2017-11-01

    Test planning and post-test correlation activity have been issues of growing importance in the last few decades and many methodologies have been developed to either quantify or improve the correlation between computational and experimental results. In this article the methodologies established so far are enhanced with the implementation of a recently developed procedure called Virtual Testing. In the context of fixed-base sinusoidal tests (commonly used in the space sector for correlation), there are several factors in the test campaign that affect the behaviour of the satellite and are not normally taken into account when performing analyses: different boundary conditions created by the shaker's own dynamics, non-perfect control system, signal delays etc. All these factors are the core of the Virtual Testing implementation, which will be thoroughly explained in this article and applied to the specific case of Bepi-Colombo spacecraft tested on the ESA QUAD Shaker. Correlation activity will be performed in the various stages of the process, showing important improvements observed after applying the final complete methodology.

  8. Correlation between subacute sensorimotor deficits and brain water content after surgical brain injury in rats

    PubMed Central

    McBride, Devin W.; Wang, Yuechun; Sherchan, Prativa; Tang, Jiping; Zhang, John H.

    2015-01-01

    Brain edema is a major contributor to poor outcome and reduced quality of life after surgical brain injury (SBI). Although SBI pathophysiology is well-known, the correlation between cerebral edema and neurological deficits has not been thoroughly examined in the rat model of SBI. Thus, the purpose of this study was to determine the correlation between brain edema and deficits in standard sensorimotor neurobehavior tests for rats subjected to SBI. Sixty male Sprague-Dawley rats were subjected to either sham surgery or surgical brain injury via partial frontal lobectomy. All animals were tested for neurological deficits 24 post-SBI and fourteen were also tested 72 hours after surgery using seven common behavior tests: modified Garcia neuroscore (Neuroscore), beam walking, corner turn test, forelimb placement test, adhesive removal test, beam balance test, and foot fault test. After assessing the functional outcome, animals were euthanized for brain water content measurement. Surgical brain injury resulted in a significantly elevated frontal lobe brain water content 24 and 72 hours after surgery compared to that of sham animals. In all behavior tests, significance was observed between sham and SBI animals. However, a correlation between brain water content and functional outcome was observed for all tests except Neuroscore. The selection of behavior tests is critical to determine the effectiveness of therapeutics. Based on this study’s results, we recommend using beam walking, the corner turn test, the beam balance test, and the foot fault test since correlations with brain water content were observed at both 24 and 72 hours post-SBI. PMID:25975171

  9. Correlation between subacute sensorimotor deficits and brain water content after surgical brain injury in rats.

    PubMed

    McBride, Devin W; Wang, Yuechun; Sherchan, Prativa; Tang, Jiping; Zhang, John H

    2015-09-01

    Brain edema is a major contributor to poor outcome and reduced quality of life after surgical brain injury (SBI). Although SBI pathophysiology is well-known, the correlation between cerebral edema and neurological deficits has not been thoroughly examined in the rat model of SBI. Thus, the purpose of this study was to determine the correlation between brain edema and deficits in standard sensorimotor neurobehavior tests for rats subjected to SBI. Sixty male Sprague-Dawley rats were subjected to either sham surgery or surgical brain injury via partial frontal lobectomy. All animals were tested for neurological deficits 24 post-SBI and fourteen were also tested 72 h after surgery using seven common behavior tests: modified Garcia neuroscore (Neuroscore), beam walking, corner turn test, forelimb placement test, adhesive removal test, beam balance test, and foot fault test. After assessing the functional outcome, animals were euthanized for brain water content measurement. Surgical brain injury resulted in significantly elevated frontal lobe brain water content 24 and 72 h after surgery compared to that of sham animals. In all behavior tests, significance was observed between sham and SBI animals. However, a correlation between brain water content and functional outcome was observed for all tests except Neuroscore. The selection of behavior tests is critical to determine the effectiveness of therapeutics. Based on this study's results, we recommend using beam walking, the corner turn test, the beam balance test, and the foot fault test since correlations with brain water content were observed at both 24 and 72 h post-SBI. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Sensitivity analysis of a sound absorption model with correlated inputs

    NASA Astrophysics Data System (ADS)

    Chai, W.; Christen, J.-L.; Zine, A.-M.; Ichchou, M.

    2017-04-01

    Sound absorption in porous media is a complex phenomenon, which is usually addressed with homogenized models, depending on macroscopic parameters. Since these parameters emerge from the structure at microscopic scale, they may be correlated. This paper deals with sensitivity analysis methods of a sound absorption model with correlated inputs. Specifically, the Johnson-Champoux-Allard model (JCA) is chosen as the objective model with correlation effects generated by a secondary micro-macro semi-empirical model. To deal with this case, a relatively new sensitivity analysis method Fourier Amplitude Sensitivity Test with Correlation design (FASTC), based on Iman's transform, is taken into application. This method requires a priori information such as variables' marginal distribution functions and their correlation matrix. The results are compared to the Correlation Ratio Method (CRM) for reference and validation. The distribution of the macroscopic variables arising from the microstructure, as well as their correlation matrix are studied. Finally the results of tests shows that the correlation has a very important impact on the results of sensitivity analysis. Assessment of correlation strength among input variables on the sensitivity analysis is also achieved.

  11. Does sensitivity measured from screening test-sets predict clinical performance?

    NASA Astrophysics Data System (ADS)

    Soh, BaoLin P.; Lee, Warwick B.; Mello-Thoms, Claudia R.; Tapia, Kriscia A.; Ryan, John; Hung, Wai Tak; Thompson, Graham J.; Heard, Rob; Brennan, Patrick C.

    2014-03-01

    Aim: To examine the relationship between sensitivity measured from the BREAST test-set and clinical performance. Background: Although the UK and Australia national breast screening programs have regarded PERFORMS and BREAST test-set strategies as possible methods of estimating readers' clinical efficacy, the relationship between test-set and real life performance results has never been satisfactorily understood. Methods: Forty-one radiologists from BreastScreen New South Wales participated in this study. Each reader interpreted a BREAST test-set which comprised sixty de-identified mammographic examinations sourced from the BreastScreen Digital Imaging Library. Spearman's rank correlation coefficient was used to compare the sensitivity measured from the BREAST test-set with screen readers' clinical audit data. Results: Results shown statistically significant positive moderate correlations between test-set sensitivity and each of the following metrics: rate of invasive cancer per 10 000 reads (r=0.495; p < 0.01); rate of small invasive cancer per 10 000 reads (r=0.546; p < 0.001); detection rate of all invasive cancers and DCIS per 10 000 reads (r=0.444; p < 0.01). Conclusion: Comparison between sensitivity measured from the BREAST test-set and real life detection rate demonstrated statistically significant positive moderate correlations which validated that such test-set strategies can reflect readers' clinical performance and be used as a quality assurance tool. The strength of correlation demonstrated in this study was higher than previously found by others.

  12. Roadmeter roughness testing in Virginia.

    DOT National Transportation Integrated Search

    1972-01-01

    A passenger car mounted PCA roadmeter has been correlated with the BPR roughometer used for road roughness testing in Virginia for many years. The results showed a good correlation and that the roadmeter is capable of excellent reproducibility. Roadm...

  13. Correlation of the Drag Characteristics of a Typical Pursuit Airplane Obtained from High-Speed Wind-Tunnel and Flight Tests

    NASA Technical Reports Server (NTRS)

    Nissen, James M; Gadebero, Burnett L; Hamilton, William T

    1948-01-01

    In order to obtain a correlation of drag data from wind-tunnel and flight tests at high Mach numbers, a typical pursuit airplane, with the propeller removed, was tested in flight at Mach numbers up to 0.755, and the results were compared with wind-tunnel tests of a 1/3-scale model of the airplane. The tests results show that the drag characteristics of the test airplane can be predicted with satisfactory accuracy from tests in the Ames 16-foot high-speed wind tunnel of the Ames Aeronautical Laboratory at both high and low Mach numbers. It is considered that this result is not unique with the airplane.

  14. Effect of Correlated Precision Errors on Uncertainty of a Subsonic Venturi Calibration

    NASA Technical Reports Server (NTRS)

    Hudson, S. T.; Bordelon, W. J., Jr.; Coleman, H. W.

    1996-01-01

    An uncertainty analysis performed in conjunction with the calibration of a subsonic venturi for use in a turbine test facility produced some unanticipated results that may have a significant impact in a variety of test situations. Precision uncertainty estimates using the preferred propagation techniques in the applicable American National Standards Institute/American Society of Mechanical Engineers standards were an order of magnitude larger than precision uncertainty estimates calculated directly from a sample of results (discharge coefficient) obtained at the same experimental set point. The differences were attributable to the effect of correlated precision errors, which previously have been considered negligible. An analysis explaining this phenomenon is presented. The article is not meant to document the venturi calibration, but rather to give a real example of results where correlated precision terms are important. The significance of the correlated precision terms could apply to many test situations.

  15. ESTIMATION OF FUNCTIONALS OF SPARSE COVARIANCE MATRICES.

    PubMed

    Fan, Jianqing; Rigollet, Philippe; Wang, Weichen

    High-dimensional statistical tests often ignore correlations to gain simplicity and stability leading to null distributions that depend on functionals of correlation matrices such as their Frobenius norm and other ℓ r norms. Motivated by the computation of critical values of such tests, we investigate the difficulty of estimation the functionals of sparse correlation matrices. Specifically, we show that simple plug-in procedures based on thresholded estimators of correlation matrices are sparsity-adaptive and minimax optimal over a large class of correlation matrices. Akin to previous results on functional estimation, the minimax rates exhibit an elbow phenomenon. Our results are further illustrated in simulated data as well as an empirical study of data arising in financial econometrics.

  16. ESTIMATION OF FUNCTIONALS OF SPARSE COVARIANCE MATRICES

    PubMed Central

    Fan, Jianqing; Rigollet, Philippe; Wang, Weichen

    2016-01-01

    High-dimensional statistical tests often ignore correlations to gain simplicity and stability leading to null distributions that depend on functionals of correlation matrices such as their Frobenius norm and other ℓr norms. Motivated by the computation of critical values of such tests, we investigate the difficulty of estimation the functionals of sparse correlation matrices. Specifically, we show that simple plug-in procedures based on thresholded estimators of correlation matrices are sparsity-adaptive and minimax optimal over a large class of correlation matrices. Akin to previous results on functional estimation, the minimax rates exhibit an elbow phenomenon. Our results are further illustrated in simulated data as well as an empirical study of data arising in financial econometrics. PMID:26806986

  17. Thermal Testing and Model Correlation for Advanced Topographic Laser Altimeter Instrument (ATLAS)

    NASA Technical Reports Server (NTRS)

    Patel, Deepak

    2016-01-01

    The Advanced Topographic Laser Altimeter System (ATLAS) part of the Ice Cloud and Land Elevation Satellite 2 (ICESat-2) is an upcoming Earth Science mission focusing on the effects of climate change. The flight instrument passed all environmental testing at GSFC (Goddard Space Flight Center) and is now ready to be shipped to the spacecraft vendor for integration and testing. This topic covers the analysis leading up to the test setup for ATLAS thermal testing as well as model correlation to flight predictions. Test setup analysis section will include areas where ATLAS could not meet flight like conditions and what were the limitations. Model correlation section will walk through changes that had to be made to the thermal model in order to match test results. The correlated model will then be integrated with spacecraft model for on-orbit predictions.

  18. Correlation between strength properties in standard test specimens and molded phenolic parts

    NASA Technical Reports Server (NTRS)

    Turner, P S; Thomason, R H

    1946-01-01

    This report describes an investigation of the tensile, flexural, and impact properties of 10 selected types of phenolic molding materials. The materials were studied to see in what ways and to what extent their properties satisfy some assumptions on which the theory of strength of materials is based: namely, (a) isotropy, (b) linear stress-strain relationship for small strains, and (c) homogeneity. The effect of changing the dimensions of tensile and flexural specimens and the span-depth ratio in flexural tests were studied. The strengths of molded boxes and flexural specimens cut from the boxes were compared with results of tests on standard test specimens molded from the respective materials. The nonuniformity of a material, which is indicated by the coefficient of variation, affects the results of tests made with specimens of different sizes and tests with different methods of loading. The strength values were found to depend on the relationship between size and shape of the molded specimen and size and shape of the fillers. The most significant variations observed within a diversified group of materials were found to depend on the orientation of fibrous fillers. Of secondary importance was the dependence of the variability of test results on the pieces of filler incorporated into the molding powder as well as on the size of the piece. Static breaking strength tests on boxes molded from six representative phenolic materials correlated well with falling-ball impact tests on specimens cut from molded flat sheets. Good correlation was obtained with Izod impact tests on standard test specimens prepared from the molding materials. The static breaking strengths of the boxes do not correlate with the results of tensile or flexural tests on standard specimens.

  19. Some Observations on the Use of the Woodcock-Johnson Tests of Cognitive Ability in Adults with Head Injury.

    ERIC Educational Resources Information Center

    Tupper, David E.

    1990-01-01

    The study provides descriptive data on use of the Woodcock-Johnson Tests of Cognitive Ability with 39 adults with closed head injury. Correlational analyses indicated significant relationships between coma duration and performance on the Perceptual Speed and Memory clusters of the test. Time since injury did not correlate with test results.…

  20. An attempt to determine the effect of increase of observation correlations on detectability and identifiability of a single gross error

    NASA Astrophysics Data System (ADS)

    Prószyński, Witold; Kwaśniak, Mieczysław

    2016-12-01

    The paper presents the results of investigating the effect of increase of observation correlations on detectability and identifiability of a single gross error, the outlier test sensitivity and also the response-based measures of internal reliability of networks. To reduce in a research a practically incomputable number of possible test options when considering all the non-diagonal elements of the correlation matrix as variables, its simplest representation was used being a matrix with all non-diagonal elements of equal values, termed uniform correlation. By raising the common correlation value incrementally, a sequence of matrix configurations could be obtained corresponding to the increasing level of observation correlations. For each of the measures characterizing the above mentioned features of network reliability the effect is presented in a diagram form as a function of the increasing level of observation correlations. The influence of observation correlations on sensitivity of the w-test for correlated observations (Förstner 1983, Teunissen 2006) is investigated in comparison with the original Baarda's w-test designated for uncorrelated observations, to determine the character of expected sensitivity degradation of the latter when used for correlated observations. The correlation effects obtained for different reliability measures exhibit mutual consistency in a satisfactory extent. As a by-product of the analyses, a simple formula valid for any arbitrary correlation matrix is proposed for transforming the Baarda's w-test statistics into the w-test statistics for correlated observations.

  1. Full-scale locomotive dynamic crash testing and correlations : locomotive consist colliding with steel coil truck at grade crossing (test 3).

    DOT National Transportation Integrated Search

    2011-09-01

    This report presents the test results and finite element correlations of a full-scale dynamic collision between a locomotive and a highway truck loaded with two heavy steel coils. The locomotive consist was moving at 58 miles per hour before it struc...

  2. Zertifikat Deutsch als Fremdsprache and the Oral Proficiency Interview: A Comparison of Test Scores and Examinations.

    ERIC Educational Resources Information Center

    Lalande, John F.; Schweckendiek, Jurgen

    1986-01-01

    Investigates what correlations might exist between an individual's score on the Zertifikat Deutsch als Fremdsprache and on the Oral Proficiency Interview. The tests themselves are briefly described. Results indicate that the two tests appear to correlate well in their evaluation of speaking skills. (SED)

  3. Point-of-Care Hemoglobin A1c Testing: An Evidence-Based Analysis

    PubMed Central

    2014-01-01

    Background The increasing prevalence of diabetes in Ontario means that there will be growing demand for hemoglobin A1c (HbA1c) testing to monitor glycemic control for the management of this chronic disease. Testing HbA1c where patients receive their diabetes care may improve system efficiency if the results from point-of-care HbA1c testing are comparable to those from laboratory HbA1c measurements. Objectives To review the correlation between point-of-care HbA1c testing and laboratory HbA1c measurement in patients with diabetes in clinical settings. Data Sources The literature search included studies published between January 2003 and June 2013. Search terms included glycohemoglobin, hemoglobin A1c, point of care, and diabetes. Review Methods Studies were included if participants had diabetes; if they compared point-of-care HbA1c devices (licensed by Health Canada and available in Canada) with laboratory HbA1c measurement (reference method); if they performed point-of-care HbA1c testing using capillary blood samples (finger pricks) and laboratory HbA1c measurement using venous blood samples within 7 days; and if they reported a correlation coefficient between point-of-care HbA1c and laboratory HbA1c results. Results Three point-of-care HbA1c devices were reviewed in this analysis: Bayer's A1cNow+, Bio-Rad's In2it, and Siemens’ DCA Vantage. Five observational studies met the inclusion criteria. The pooled results showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement (correlation coefficient, 0.967; 95% confidence interval, 0.960–0.973). Limitations Outcomes were limited to the correlation coefficient, as this was a commonly reported measure of analytical performance in the literature. Results should be interpreted with caution due to risk of bias related to selection of participants, reference standards, and the multiple steps involved in POC HbA1c testing. Conclusions Moderate quality evidence showed a positive correlation between point-of-care HbA1c testing and laboratory HbA1c measurement. Five observational studies compared 3 point-of-care HbA1c devices with laboratory HbA1c assays, and all reported strong correlation between the 2 tests. PMID:26316922

  4. Variations in the detection of ZAP-70 in chronic lymphocytic leukemia: Comparison with IgV(H) mutation analysis.

    PubMed

    Sheikholeslami, M R; Jilani, I; Keating, M; Uyeji, J; Chen, K; Kantarjian, H; O'Brien, S; Giles, F; Albitar, M

    2006-07-15

    Lack of immunoglobulin heavy chain genes (IgV(H)) mutation in patients with chronic lymphocytic leukemia (CLL) is associated with rapid disease progression and shorter survival. The zeta-chain (T-cell receptor) associated protein kinase 70 kDa (ZAP-70) has been reported to be a surrogate marker for IgV(H) mutation status, and its expression in leukemic cells correlates with unmutated IgV(H). However, ZAP-70 detection by flow cytometry varies significantly dependant on the antibodies used, the method of performing the assay, and the condition of the cells in the specimen. The clinical value of ZAP-70 testing when samples are shipped under poorly controlled conditions is not known. Furthermore, testing in a research environment may differ from testing in a routine clinical laboratory. We validated an assay for ZAP-70 by comparing results with clinical outcome and the mutation status of the IgV(H). Using stored samples, we show significant correlation between ZAP-70 expression and clinical outcome as well as IgV(H) mutation at a cut-off point of 15%. While positive samples (>15% positivity) remain positive when kept in the laboratory environment for 48 h after initial testing, results obtained from samples from CLL patients tested after shipping at room temperature for routine testing showed no correlation with IgV(H) mutation status when 15% cut-off was used. In these samples, cut-point of 10% correlated with the IgV(H) mutation (P = 0.0001). This data suggests that although ZAP-70 positivity correlates with IgV(H) mutation status and survival, variations in sample handling and preparation may influence results. We show that IgV(H) mutation results, unlike ZAP-70 remain correlated with CD38 expression and beta-2 microglobulin in shipped samples, and ZAP-70 testing should not be used as the sole criterion for stratifying patients for therapy. (c) 2006 International Society for Analytical Cytology.

  5. Evaluation of 2 cognitive abilities tests in a dual-task environment

    NASA Technical Reports Server (NTRS)

    Vidulich, M. A.; Tsang, P. S.

    1986-01-01

    Most real world operators are required to perform multiple tasks simultaneously. In some cases, such as flying a high performance aircraft or trouble shooting a failing nuclear power plant, the operator's ability to time share or process in parallel" can be driven to extremes. This has created interest in selection tests of cognitive abilities. Two tests that have been suggested are the Dichotic Listening Task and the Cognitive Failures Questionnaire. Correlations between these test results and time sharing performance were obtained and the validity of these tests were examined. The primary task was a tracking task with dynamically varying bandwidth. This was performed either alone or concurrently with either another tracking task or a spatial transformation task. The results were: (1) An unexpected negative correlation was detected between the two tests; (2) The lack of correlation between either test and task performance made the predictive utility of the tests scores appear questionable; (3) Pilots made more errors on the Dichotic Listening Task than college students.

  6. Compression failure of angle-ply laminates

    NASA Technical Reports Server (NTRS)

    Peel, L. D.; Hyer, M. W.; Shuart, M. J.

    1992-01-01

    Test results from the compression loading of (+ or - Theta/ - or + Theta)(sub 6s) angle-ply IM7-8551-7a specimens, 0 less than or = Theta less than or = 90 degs, are presented. The observed failure strengths and modes are discussed, and typical stress-strain relations shown. Using classical lamination theory and the maximum stress criterion, an attempt is made to predict failure stress as a function of Theta. This attempt results in poor correlation with test results and thus a more advanced model is used. The model, which is based on a geometrically nonlinear theory, and which was taken from previous work, includes the influence of observed layer waviness. The waviness is described by the wave length and the wave amplitude. The theory is briefly described and results from the theory are correlated with test results. It is shown that by using levels of waviness observed in the specimens, the correlation between predictions and observations is good.

  7. Hypothesis testing for differentially correlated features.

    PubMed

    Sheng, Elisa; Witten, Daniela; Zhou, Xiao-Hua

    2016-10-01

    In a multivariate setting, we consider the task of identifying features whose correlations with the other features differ across conditions. Such correlation shifts may occur independently of mean shifts, or differences in the means of the individual features across conditions. Previous approaches for detecting correlation shifts consider features simultaneously, by computing a correlation-based test statistic for each feature. However, since correlations involve two features, such approaches do not lend themselves to identifying which feature is the culprit. In this article, we instead consider a serial testing approach, by comparing columns of the sample correlation matrix across two conditions, and removing one feature at a time. Our method provides a novel perspective and favorable empirical results compared with competing approaches. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  8. The relationship between white matter abnormalities and cognitive functions in new-onset juvenile myoclonic epilepsy.

    PubMed

    Ekmekci, Burcu; Bulut, Hacı Taner; Gümüştaş, Funda; Yıldırım, Adem; Kuştepe, Ali

    2016-09-01

    Diffusion tensor imaging (DTI) has revealed evidence of subcortical white matter abnormalities in the frontal area in juvenile myoclonic epilepsy (JME). Decreased fractional anisotropy (FA) and increased mean diffusivity (MD) in the corticothalamic pathway have been detected in adult patients with JME. It has been demonstrated that, in adult patients with JME, frontal dysfunction is related to subcortical white matter damage and decreased volume in frontal cortical gray matter and the thalamus. Many studies have focused on adult patients. Twenty-four patients and 28 controls were evaluated. The group with JME had significantly worse results for the word fluency, trail-B, and Stroop tests that assessed executive functions. A significant decrease in FA values in the dorsolateral prefrontal cortex (DLPFC), the supplementary motor area (SMA), the right thalamus, the posterior cingulate, the corpus callosum anterior, the corona radiata, and the middle frontal white matter (MFWM) and an increase in ADC values in patients with JME were detected. The correlation between FA values in DLPFC and the letter fluency test results was positive, and the correlation with the Stroop and trail-B test results was negative. We found a negative correlation between SMA, anterior thalamus, and MFWM FA values and the trail-B test results and a positive correlation between the SMA, anterior thalamus, and MFWM FA values and the letter fluency test results. We detected white matter and gray matter abnormalities in patients with new-onset JME using DTI. In addition, we determined the relationship between cognitive deficit and microstructural abnormalities by evaluating the correlation between the neuropsychological test battery results and DTI parameters. We evaluated newly diagnosed patients with JME in our study. That leads us to believe that microstructural abnormalities exist from the very beginning of the disease and that they result from the genetic basis of the disease. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Inference for High-dimensional Differential Correlation Matrices.

    PubMed

    Cai, T Tony; Zhang, Anru

    2016-01-01

    Motivated by differential co-expression analysis in genomics, we consider in this paper estimation and testing of high-dimensional differential correlation matrices. An adaptive thresholding procedure is introduced and theoretical guarantees are given. Minimax rate of convergence is established and the proposed estimator is shown to be adaptively rate-optimal over collections of paired correlation matrices with approximately sparse differences. Simulation results show that the procedure significantly outperforms two other natural methods that are based on separate estimation of the individual correlation matrices. The procedure is also illustrated through an analysis of a breast cancer dataset, which provides evidence at the gene co-expression level that several genes, of which a subset has been previously verified, are associated with the breast cancer. Hypothesis testing on the differential correlation matrices is also considered. A test, which is particularly well suited for testing against sparse alternatives, is introduced. In addition, other related problems, including estimation of a single sparse correlation matrix, estimation of the differential covariance matrices, and estimation of the differential cross-correlation matrices, are also discussed.

  10. Comparative Performance of Reagents and Platforms for Quantitation of Cytomegalovirus DNA by Digital PCR

    PubMed Central

    Gu, Z.; Sam, S. S.; Sun, Y.; Tang, L.; Pounds, S.; Caliendo, A. M.

    2016-01-01

    A potential benefit of digital PCR is a reduction in result variability across assays and platforms. Three sets of PCR reagents were tested on two digital PCR systems (Bio-Rad and RainDance), using three different sets of PCR reagents for quantitation of cytomegalovirus (CMV). Both commercial quantitative viral standards and 16 patient samples (n = 16) were tested. Quantitative accuracy (compared to nominal values) and variability were determined based on viral standard testing results. Quantitative correlation and variability were assessed with pairwise comparisons across all reagent-platform combinations for clinical plasma sample results. The three reagent sets, when used to assay quantitative standards on the Bio-Rad system, all showed a high degree of accuracy, low variability, and close agreement with one another. When used on the RainDance system, one of the three reagent sets appeared to have a much better correlation to nominal values than did the other two. Quantitative results for patient samples showed good correlation in most pairwise comparisons, with some showing poorer correlations when testing samples with low viral loads. Digital PCR is a robust method for measuring CMV viral load. Some degree of result variation may be seen, depending on platform and reagents used; this variation appears to be greater in samples with low viral load values. PMID:27535685

  11. Manifestations of interpersonal dependency and depressive subtypes in outpatient psychotherapy patients.

    PubMed

    Huprich, Steven; Rosen, Alexandra; Kiss, Andrea

    2013-08-01

    The present study investigated the relationship between normative and pathological dependency and anaclitic and introjective depressive experiences among 71 patients participating in outpatient psychotherapy at a university-based psychology clinic. We examined the interrelationships among the Relationship Profile Test subscales, the Depressive Experiences Questionnaire subscales and the Outcome Questionnaire-45.2. Results indicated that destructive overdependence was positively correlated with anaclitic and introjective depression and negatively correlated with overall perceptions of mental health. Dysfunctional detachment was positively correlated with introjective depression and negatively correlated with generalized perceptions of one's own mental health. Healthy dependency was negatively correlated with introjective depression and positively correlated with mental health. These results not only support the construct validity of the Relationship Profile Test but also shed light on a link between depression, dependence and self-criticism. Copyright © 2013 John Wiley & Sons, Ltd.

  12. An evaluation of the utility of four in situ test methods for transmission line foundation design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mullen, W.G. Jr.

    1991-01-01

    This research examines four existing in-situ soil strength testing methods; standard penetration test (SPT), the cone penetrometer (CPT), the flat plate dilatometer (DMT), and the pressuremeter (PMT). Soils data were collected at eight separate sites using each of the devices. The test sites were chosen to mirror soil conditions encountered within the service territory of Virginia Power, the project sponsor. A total of 19 standard soil borings, 30 cone penetrometer soundings, 26 dilatometer soundings, and 33 pressuremeter tests were undertaken in residual, alluvial and marine clay soil conditions. The testing program was conducted with five areas of concern: (1) comparisonmore » of the penetration/stiffness data from the four tests, (2) comparison of values of undrained shear strength and angle of internal friction developed from each of the test methods, (3) determination if pressuremeter data can be correlated to and thereby developed from one of the more rapid tests, (4) comparison of indirect soil type identifications from the standard borings, (5) development of information on the relative effort required for each test. Comparison of the penetration resistance stiffness data produced useful correlations among the CPT and DMT, with the SPT data yielding more erratic results. Shear strength data was most consistent for the marine clay sites, while the CPT and DMT returned useful friction angle data in the alluvial sands. PMT data correlated well to both the CPT and DMT test results. Correlation of PMT results to the SPT was more erratic. Indirect soil identification from the CPT and DMT was fully adequate for transmission line foundation design purposes, and finally, useful comparative data on the relative testing time required for the four in-situ tests was developed.« less

  13. The Leeb Hardness Test for Rock: An Updated Methodology and UCS Correlation

    NASA Astrophysics Data System (ADS)

    Corkum, A. G.; Asiri, Y.; El Naggar, H.; Kinakin, D.

    2018-03-01

    The Leeb hardness test (LHT with test value of L D ) is a rebound hardness test, originally developed for metals, that has been correlated with the Unconfined Compressive Strength (test value of σ c ) of rock by several authors. The tests can be carried out rapidly, conveniently and nondestructively on core and block samples or on rock outcrops. This makes the relatively small LHT device convenient for field tests. The present study compiles test data from literature sources and presents new laboratory testing carried out by the authors to develop a substantially expanded database with wide-ranging rock types. In addition, the number of impacts that should be averaged to comprise a "test result" was revisited along with the issue of test specimen size. Correlation for L D and σ c for various rock types is provided along with recommended testing methodology. The accuracy of correlated σ c estimates was assessed and reasonable correlations were observed between L D and σ c . The study findings show that LHT can be useful particularly for field estimation of σ c and offers a significant improvement over the conventional field estimation methods outlined by the ISRM (e.g., hammer blows). This test is rapid and simple, with relatively low equipment costs, and provides a reasonably accurate estimate of σ c .

  14. Correlation Between Timed Barium Esophagogram and Esophageal Transit Scintigraphy Results in Achalasia.

    PubMed

    Park, Yoo Mi; Jeon, Han Ho; Park, Jae Jun; Kim, Jie-Hyun; Youn, Young Hoon; Park, Hyojin

    2015-08-01

    Timed barium esophagogram (TBE) and esophageal transit scintigraphy (ETS) have been adopted as useful ways to evaluate achalasia patients. TBE has merit as a simple, non-invasive, and convenient method. The study sought to compare the results of these two tests and verify their usefulness in evaluating treatment response. In addition, we assessed whether TBE could effectively replace ETS through correlation analysis. The medical records of 50 achalasia patients treated between September 2011 and June 2014 were reviewed retrospectively. The height and width of the barium column at 1, 2, and 5 min were measured by TBE. Half-life (T 1/2, min) and R 30 (percentage of remaining radioactivity 30 s after radioisotope ingestion) were measured by ETS. Both tests were performed before and after treatment, and the tests were carried out 1 and 2 days after procedures. And we analyzed the correlation between the parameters from the two tests. The parameters of TBE and ETS were improved after treatment (p < 0.05). Before treatment, the height and width results at 5 min from TBE positively correlated with the T 1/2 parameter from ETS (correlation coefficients of 0.59 and 0.75, respectively). After treatment, the correlation coefficients between the 5-min height and width of the barium column by TBE and T 1/2 by ETS were 0.55 and 0.46, respectively. Both TBE and ETS are useful modalities in assessing esophageal emptying and response to achalasia treatment. TBE and ETS results have a statistically significant correlation both pre- and post-treatment. We suggest that TBE could effectively replace ETS for the assessment of achalasia.

  15. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing - Part 2

    NASA Technical Reports Server (NTRS)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerome C.; Kolody, Mark R.

    2012-01-01

    Evaluation of metals to predict service life of metal-based structures in corrosive environments has long relied on atmospheric exposure test sites. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions similar to those of the corrosive environment. Their reliability to correlate to atmospheric exposure test results is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated corrosion testing has yet to be universally accepted as a useful tool in predicting the long-term service life of a metal, despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard, and their use is crucial, a method that correlates timescales from accelerated testing to atmospheric exposure would be very valuable. This paper presents work that began with the characterization of the atmospheric environment at the Kennedy Space Center (KSC) Beachside Corrosion Test Site. The chemical changes that occur on low carbon steel, during atmospheric and accelerated corrosion conditions, were investigated using surface chemistry analytical methods. The corrosion rates and behaviors of panels subjected to long-term and accelerated corrosion conditions, involving neutral salt fog and alternating seawater spray, were compared to identify possible timescale correlations between accelerated and long-term corrosion performance. The results, as well as preliminary findings on the correlation investigation, are presented.

  16. A Maximum Entropy Test for Evaluating Higher-Order Correlations in Spike Counts

    PubMed Central

    Onken, Arno; Dragoi, Valentin; Obermayer, Klaus

    2012-01-01

    Evaluating the importance of higher-order correlations of neural spike counts has been notoriously hard. A large number of samples are typically required in order to estimate higher-order correlations and resulting information theoretic quantities. In typical electrophysiology data sets with many experimental conditions, however, the number of samples in each condition is rather small. Here we describe a method that allows to quantify evidence for higher-order correlations in exactly these cases. We construct a family of reference distributions: maximum entropy distributions, which are constrained only by marginals and by linear correlations as quantified by the Pearson correlation coefficient. We devise a Monte Carlo goodness-of-fit test, which tests - for a given divergence measure of interest - whether the experimental data lead to the rejection of the null hypothesis that it was generated by one of the reference distributions. Applying our test to artificial data shows that the effects of higher-order correlations on these divergence measures can be detected even when the number of samples is small. Subsequently, we apply our method to spike count data which were recorded with multielectrode arrays from the primary visual cortex of anesthetized cat during an adaptation experiment. Using mutual information as a divergence measure we find that there are spike count bin sizes at which the maximum entropy hypothesis can be rejected for a substantial number of neuronal pairs. These results demonstrate that higher-order correlations can matter when estimating information theoretic quantities in V1. They also show that our test is able to detect their presence in typical in-vivo data sets, where the number of samples is too small to estimate higher-order correlations directly. PMID:22685392

  17. Testing the Forensic Interestingness of Image Files Based on Size and Type

    DTIC Science & Technology

    2017-09-01

    there were still a lot of uninteresting files that were marked as interesting. Also, the results do not show a correlation between the...interesting, but there were still a lot of uninteresting files that were marked as interesting. Also, the results do not show a correlation between...7  IV.  DESCRIPTION OF METHODOLOGY ...........................................................11  A.  TEST SETUP

  18. Reliability, Validity, and Cross-Cultural Adaptation of the Turkish Version of the Bournemouth Questionnaire.

    PubMed

    Gunaydin, Gurkan; Citaker, Seyit; Meray, Jale; Cobanoglu, Gamze; Gunaydin, Ozge Ece; Hazar Kanik, Zeynep

    2016-11-01

    Validation of a self-report questionnaire. The purpose of this study was to investigate adaptation, validity, and reliability of the Turkish version of the Bournemouth Questionnaire. Low back pain is one of the most frequent disorders leading to activity limitation. This pain affects most of people in their lives. The most important point to evaluate patient's functional abilities and to decide a successful therapy procedure is to manage the assessment questionnaires precisely. One hundred ten patients with chronic low back pain were included in present study. To assess reliability, test-retest and internal consistency analyses were applied. The results of test-retest analysis were assessed by using Intraclass Correlation Coefficient method (95% confidence interval). For internal consistency, Cronbach alpha value was calculated. Validity of the questionnaire was assessed in terms of construct validity. For construct validity, factor analysis and convergent validity were tested. For convergent validity, total points of the Bournemouth Questionnaire were assessed with the total points of Quebec Back Pain Disability Scale and Roland Morris Disability Questionnaire by using Pearson correlation coefficient analysis. Cronbach alpha value was found 0.914, showing that this questionnaire has high internal consistency. The results of test-retest analysis were varying between 0.851 and 0.927, which shows that test-retest results are highly correlated. Factor analysis test indicated that this questionnaire had one factor. Pearson correlation coefficient of the Bournemouth Questionnaire with Roland Morris Disability Questionnaire was calculated 0.703 and it was found with Quebec Back Pain Disability Scale is 0.659. These results showed that the Bournemouth Questionnaire is very good correlated with Roland Morris Disability Questionnaire and Quebec Back Pain Disability Scale. The Turkish version of the Bournemouth Questionnaire is valid and reliable. 3.

  19. Hand rehabilitation using MIDI keyboard playing in adolescents with brain damage: a preliminary study.

    PubMed

    Chong, Hyun Ju; Cho, Sung-Rae; Kim, Soo Ji

    2014-01-01

    As a sequential, programmed movement of fingers, keyboard playing is a promising technique for inducing execution and a high level of coordination during finger movements. Also, keyboard playing can be physically and emotionally rewarding for adolescents in rehabilitation settings and thereby motivate continued involvement in treatment. The purpose of this study is to evaluate the effects of keyboard playing using Musical Instrument Digital Interface (MIDI) on finger movement for adolescents with brain damage. Eight adolescents with brain damage, ages 9 to 18 years (M = 13 years, SD = 2.78), in physical rehabilitation settings participated in this study. Measurements included MIDI keyboard playing for pressing force of the fingers and hand function tests (Grip and Pinch Power Test, Box and Block Test of Manual Dexterity [BBT], and the Jebsen Taylor Hand Function Test). Results showed increased velocity of all fingers on the MIDI-based test, and statistical significance was found in the velocity of F2 (index finger), F3 (middle finger), and F5 (little finger) between pre- and post-training tests. Correlation analysis between the pressing force of the finger and hand function tests showed a strong positive correlation between the measure of grip power and the pressing force of F2 and F5 on the Grip and Pinch Strength Test. All fingers showed strong correlation between MIDI results and BBT. For the Jebsen Taylor Hand Function Test, only the moving light objects task at post-training yielded strong correlation with MIDI results of all fingers. The results support using keyboard playing for hand rehabilitation, especially in the pressing force of individual finger sequential movements. Further investigation is needed to define the feasibility of the MIDI program for valid hand rehabilitation for people with brain damage.

  20. Rheological behavior of FM-9 solutions and correlation with flammability test results and interpretations. [fuel thickening additive

    NASA Technical Reports Server (NTRS)

    Peng, S. T. J.; Landel, R. F.

    1983-01-01

    The rheological behavior of progressively shear thickening FM-9 solutions, a time-dependent shear thickening material with characteristics of threshold behavior, is investigated as part of a study of the rheological properties of antimisting jet fuel. Flammability test results and test configurations from various sources are evaluated. A correlation is obtained between the rheological behavior and the flammability tests such that, for a given system, such as a fixed solvent system and the FM-9 polymer system, the flammability criterion can be applied to a wide range of concentrations and temperatures.

  1. Situational judgment test as an additional tool in a medical admission test: an observational investigation.

    PubMed

    Luschin-Ebengreuth, Marion; Dimai, Hans P; Ithaler, Daniel; Neges, Heide M; Reibnegger, Gilbert

    2015-03-14

    In the framework of medical university admission procedures the assessment of non-cognitive abilities is increasingly demanded. As tool for assessing personal qualities or the ability to handle theoretical social constructs in complex situations, the Situational Judgment Test (SJT), among other measurement instruments, is discussed in the literature. This study focuses on the development and the results of the SJT as part of the admission test for the study of human medicine and dentistry at one medical university in Austria. Observational investigation focusing on the results of the SJT. 4741 applicants were included in the study. To yield comparable results for the different test parts, "relative scores" for each test part were calculated. Performance differences between women and men in the various test parts are analyzed using effect sizes based on comparison of mean values (Cohen's d). The associations between the relative scores achieved in the various test parts were assessed by computing pairwise linear correlation coefficients between all test parts and visualized by bivariate scatterplots. Among successful candidates, men consistently outperform women. Men perform better in physics and mathematics. Women perform better in the SJT part. The least discriminatory test part was the SJT. A strong correlation between biology and chemistry and moderate correlations between the other test parts except SJT is obvious. The relative scores are not symmetrically distributed. The cognitive loading of the performed SJTs points to the low correlation between the SJTs and cognitive abilities. Adding the SJT part into the admission test, in order to cover more than only knowledge and understanding of natural sciences among the applicants has been quite successful.

  2. Pneumatic testing in 45-degree-inclined boreholes in ash-flow tuff near Superior, Arizona

    USGS Publications Warehouse

    LeCain, G.D.

    1995-01-01

    Matrix permeability values determined by single-hole pneumatic testing in nonfractured ash-flow tuff ranged from 5.1 to 20.3 * 1046 m2 (meters squared), depending on the gas-injection rate and analysis method used. Results from the single-hole tests showed several significant correlations between permeability and injection rate and between permeability and test order. Fracture permeability values determined by cross-hole pneumatic testing in fractured ash-flow tuff ranged from 0.81 to 3.49 * 1044 m2, depending on injection rate and analysis method used. Results from the cross-hole tests monitor intervals showed no significant correlation between permeability and injection rate; however, results from the injection interval showed a significant correlation between injection rate and permeability. Porosity estimates from the 'cross-hole testing range from 0.8 to 2.0 percent. The maximum temperature change associated with the pneumatic testing was 1.2'(2 measured in the injection interval during cross-hole testing. The maximum temperature change in the guard and monitor intervals was O.Ip C. The maximum error introduced into the permeability values due to temperature fluctuations is approximately 4 percent. Data from temperature monitoring in the borehole indicated a positive correlation between the temperature decrease in the injection interval during recovery testing and the gas-injection rate. The thermocouple psychrometers indicated that water vapor was condensing in the boreholes during testing. The psychrometers in the guard and monitor intervals detected the drier injected gas as an increase in the dry bulb reading. The relative humidity in the test intervals was always higher than the upper measurement limit of the psychrometers. Although the installation of the packer system may have altered the water balance of the borehole, the gas-injection testing resulted in minimal or no changes in the borehole relative humidity.

  3. Unidimensional factor models imply weaker partial correlations than zero-order correlations.

    PubMed

    van Bork, Riet; Grasman, Raoul P P P; Waldorp, Lourens J

    2018-06-01

    In this paper we present a new implication of the unidimensional factor model. We prove that the partial correlation between two observed variables that load on one factor given any subset of other observed variables that load on this factor lies between zero and the zero-order correlation between these two observed variables. We implement this result in an empirical bootstrap test that rejects the unidimensional factor model when partial correlations are identified that are either stronger than the zero-order correlation or have a different sign than the zero-order correlation. We demonstrate the use of the test in an empirical data example with data consisting of fourteen items that measure extraversion.

  4. Sensitivity to tomato and peanut allergens in children monosensitized to grass pollen.

    PubMed

    de Martino, M; Novembre, E; Cozza, G; de Marco, A; Bonazza, P; Vierucci, A

    1988-04-01

    Possible associations between allergy to grass pollen and positive skin tests to food allergens were studied in 102 children monosensitized (as to inhalant allergens) to grass pollen, and in 117 children monosensitized (as to inhalant allergens) to Dermatophagoides. Thirty-two foods were tested by an epicutaneous method. Positive skin tests to food allergens were more frequent in children with allergy to grass pollen (59.8%) than in children with allergy to Dermatophagoides (9.4%). A considerably high frequency of positive reactions to tomato (39.2%), peanut (22,5%), green pea (13.7%), and wheat (11.7%) was observed in children with allergy to grass pollen. Positive skin tests to peanut closely correlated with positive RAST results and nasal provocation tests, whereas in children with skin test positivity to tomato a close correlation with nasal provocation tests but a 45% correlation with a positive RAST result were observed. RAST inhibition experiments were carried out, and the results may suggest the presence of cross-reacting IgE to grass pollen, tomato, and peanut antigens. Clinical implications of these findings are discussed in the light of histories of food hypersensitivity, urticaria-angioedema, and atopic dermatitis in children with allergy to grass pollen.

  5. Flue gas desulfurization chemistry studies: limestone grindability. Volume 2. Grindability testing. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richmann, D.L.; Luke, K.W.; Terry, J.C.

    1984-07-01

    The results of a study to determine the relative grindability of US limestones and to relate grindability to petrographic properties are presented in this report. A laboratory ball mill test was developed to provide a quick and simple measure of grindability. These values were then used to explore possible correlations between grindability and the chemical and physical properties of the limestones. Chemical analyses and thin section petrographic analyses were used to characterize the limestone samples. The results of the laboratory ball mill test were compared to the results of an industrial grinding test, the Bond Work Index, for six samplesmore » which covered the grindability range. The two tests compared well with a correlation coefficient greater than 0.9. While the laboratory test is not sufficient to provide ball mill design specifications, it can be used as a screening and quality control test. The grinding results, expressed as a grindability index, ranged in values from 2 to 15. This represents a seven-fold range in the relative difficulties to grind for the limestones tested. From the petrographic analysis results, a strong correlation was found between the grindability and the fraction of macrocrystalline (> 5 ..mu..m) carbonate minerals present in the limestone. However, based on the high degree of variability characteristic of most limestone deposits, petrographic information should, in general, only be used to qualitatively predict the grindability of a specific limestone. An actual grinding test is recommended for a quantitative evaluation.« less

  6. Correlation Results for a Mass Loaded Vehicle Panel Test Article Finite Element Models and Modal Survey Tests

    NASA Technical Reports Server (NTRS)

    Maasha, Rumaasha; Towner, Robert L.

    2012-01-01

    High-fidelity Finite Element Models (FEMs) were developed to support a recent test program at Marshall Space Flight Center (MSFC). The FEMs correspond to test articles used for a series of acoustic tests. Modal survey tests were used to validate the FEMs for five acoustic tests (a bare panel and four different mass-loaded panel configurations). An additional modal survey test was performed on the empty test fixture (orthogrid panel mounting fixture, between the reverb and anechoic chambers). Modal survey tests were used to test-validate the dynamic characteristics of FEMs used for acoustic test excitation. Modal survey testing and subsequent model correlation has validated the natural frequencies and mode shapes of the FEMs. The modal survey test results provide a basis for the analysis models used for acoustic loading response test and analysis comparisons

  7. Flight Test of Orthogonal Square Wave Inputs for Hybrid-Wing-Body Parameter Estimation

    NASA Technical Reports Server (NTRS)

    Taylor, Brian R.; Ratnayake, Nalin A.

    2011-01-01

    As part of an effort to improve emissions, noise, and performance of next generation aircraft, it is expected that future aircraft will use distributed, multi-objective control effectors in a closed-loop flight control system. Correlation challenges associated with parameter estimation will arise with this expected aircraft configuration. The research presented in this paper focuses on addressing the correlation problem with an appropriate input design technique in order to determine individual control surface effectiveness. This technique was validated through flight-testing an 8.5-percent-scale hybrid-wing-body aircraft demonstrator at the NASA Dryden Flight Research Center (Edwards, California). An input design technique that uses mutually orthogonal square wave inputs for de-correlation of control surfaces is proposed. Flight-test results are compared with prior flight-test results for a different maneuver style.

  8. Free-Suspension Residual Flexibility Testing of Space Station Pathfinder: Comparison to Fixed-Base Results

    NASA Technical Reports Server (NTRS)

    Tinker, Michael L.

    1998-01-01

    Application of the free-suspension residual flexibility modal test method to the International Space Station Pathfinder structure is described. The Pathfinder, a large structure of the general size and weight of Space Station module elements, was also tested in a large fixed-base fixture to simulate Shuttle Orbiter payload constraints. After correlation of the Pathfinder finite element model to residual flexibility test data, the model was coupled to a fixture model, and constrained modes and frequencies were compared to fixed-base test. modes. The residual flexibility model compared very favorably to results of the fixed-base test. This is the first known direct comparison of free-suspension residual flexibility and fixed-base test results for a large structure. The model correlation approach used by the author for residual flexibility data is presented. Frequency response functions (FRF) for the regions of the structure that interface with the environment (a test fixture or another structure) are shown to be the primary tools for model correlation that distinguish or characterize the residual flexibility approach. A number of critical issues related to use of the structure interface FRF for correlating the model are then identified and discussed, including (1) the requirement of prominent stiffness lines, (2) overcoming problems with measurement noise which makes the antiresonances or minima in the functions difficult to identify, and (3) the use of interface stiffness and lumped mass perturbations to bring the analytical responses into agreement with test data. It is shown that good comparison of analytical-to-experimental FRF is the key to obtaining good agreement of the residual flexibility values.

  9. A comparison of paper-and-pencil and computerized forms of Line Orientation and Enhanced Cued Recall Tests.

    PubMed

    Aşkar, Petek; Altun, Arif; Cangöz, Banu; Cevik, Vildan; Kaya, Galip; Türksoy, Hasan

    2012-04-01

    The purpose of this study was to assess whether a computerized battery of neuropsychological tests could produce similar results as the conventional forms. Comparisons on 77 volunteer undergraduates were carried out with two neuropsychological tests: Line Orientation Test and Enhanced Cued Recall Test. Firstly, students were assigned randomly across the test medium (paper-and-pencil versus computerized). Secondly, the groups were given the same test in the other medium after a 30-day interval between tests. Results showed that the Enhanced Cued Recall Test-Computer-based did not correlate with the Enhanced Cued Recall Test-Paper-and-pencil results. Line Orientation Test-Computer-based scores, on the other hand, did correlate significantly with the Line Orientation Test-Paper-and-pencil version. In both tests, scores were higher on paper-and-pencil tests compared to computer-based tests. Total score difference between modalities was statistically significant for both Enhanced Cued Recall Tests and for the Line Orientation Test. In both computer-based tests, it took less time for participants to complete the tests.

  10. On the road performance tests of electric test vehicle for correlation with road load simulator

    NASA Technical Reports Server (NTRS)

    Dustin, M. O.; Slavik, R. J.

    1982-01-01

    A dynamometer (road load simulator) is used to test and evaluate electric vehicle propulsion systems. To improve correlation between system tests on the road load simulator and on the road, similar performance tests are conducted using the same vehicle. The results of track tests on the electric propulsion system test vehicle are described. The tests include range at constant speeds and over SAE J227a driving cycles, maximum accelerations, maximum gradability, and tire rolling resistance determination. Road power requirements and energy consumption were also determined from coast down tests.

  11. Prognostic value of a pre-freeze hypo-osmotic swelling test on the post-thaw quality of dog semen.

    PubMed

    Karger, S; Geiser, B; Grau, M; Burfeind, O; Heuwieser, W; Arlt, S P

    2016-03-01

    Throughout cryopreservation, sperm are exposed to major osmotic challenges. Only intact membranes of sperm cells are able to regulate these volumetric changes, which can be determined by the hypo-osmotic swelling test (HOS test). Correlations between the HOS test and conventional semen variables are inconsistent. Therefore, the objectives of this study were (1) to examine relationships between HOS test results and standard semen variables before freezing and after thawing and (2) to evaluate the prognostic value of the HOS assessments on post-thaw quality of dog semen. Semen of 35 dogs was collected and analyzed before freezing and after thawing following a 7-day freeze-thaw interval. Conventional semen variables such as sperm cell motility, membrane integrity morphology were evaluated and the HOS test was conducted with results from this test being recorded. In fresh semen the HOS test was positively correlated with progressive motility of sperm cells: r=0.52, sperm cell membrane integrity: r=0.50 and normal sperm cell morphology: r=0.46 (P<0.05). In frozen-thawed semen, the data obtained with the HOS test were positively correlated with progressive sperm cell motility: r=0.67 and membrane integrity: r=0.86 (P<0.05). The data obtained with the HOS test in fresh semen were positively correlated with sperm cell membrane integrity: r=0.50 normal sperm cell morphology: r=0.55 and data from the HOS test (r=0.43; P<0.05) with frozen-thawed semen. For the prediction of individual cryopreservation capacity, results from assessment of the fresh semen variables of good and poor semen quality were statistically compared. Based on these results, it is not possible to predict the quality of frozen-thawed dog semen using the HOS test. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. A test of the hypothesis that correlational selection generates genetic correlations.

    PubMed

    Roff, Derek A; Fairbairn, Daphne J

    2012-09-01

    Theory predicts that correlational selection on two traits will cause the major axis of the bivariate G matrix to orient itself in the same direction as the correlational selection gradient. Two testable predictions follow from this: for a given pair of traits, (1) the sign of correlational selection gradient should be the same as that of the genetic correlation, and (2) the correlational selection gradient should be positively correlated with the value of the genetic correlation. We test this hypothesis with a meta-analysis utilizing empirical estimates of correlational selection gradients and measures of the correlation between the two focal traits. Our results are consistent with both predictions and hence support the underlying hypothesis that correlational selection generates a genetic correlation between the two traits and hence orients the bivariate G matrix. © 2012 The Author(s). Evolution© 2012 The Society for the Study of Evolution.

  13. Test Anxiety Among College Students With Specific Reading Disability (Dyslexia): Nonverbal Ability and Working Memory as Predictors.

    PubMed

    Nelson, Jason M; Lindstrom, Will; Foels, Patricia A

    2015-01-01

    Test anxiety and its correlates were examined with college students with and without specific reading disability (RD; n = 50 in each group). Results indicated that college students with RD reported higher test anxiety than did those without RD, and the magnitude of these differences was in the medium range on two test anxiety scales. Relative to college students without RD, up to 5 times as many college students with RD reported clinically significant test anxiety. College students with RD reported significantly higher cognitively based test anxiety than physically based test anxiety. Reading skills, verbal ability, and processing speed were not correlated with test anxiety. General intelligence, nonverbal ability, and working memory were negatively correlated with test anxiety, and the magnitude of these correlations was medium to large. When these three cognitive constructs were considered together in multiple regression analyses, only working memory and nonverbal ability emerged as significant predictors and varied based on the test anxiety measure. Implications for assessment and intervention are discussed. © Hammill Institute on Disabilities 2013.

  14. Comparison of FibroTest-ActiTest with histopathology in demonstrating fibrosis and necroinflammatory activity in chronic hepatitis B and C.

    PubMed

    Uyar, Cemile; Akcam, Fusun Zeynep; Ciris, Metin; Kaya, Onur; Kockar, Cem; Isler, Mehmet

    2010-01-01

    FibroTest and ActiTest are noninvasive tests used in determining the level of fibrosis and the degree of necroinflammatory activity in the liver. In our study, we aimed to investigate whether these tests could be alternative to liver biopsy. Fifty patients were included in the study. Serum samples were obtained and liver needle biopsy was performed on the same day. Levels of fibrosis in FibroTest and levels of activity in ActiTest, both determined via serum biochemical markers, were compared with levels of fibrosis and activity in histopathological examination. For statistical analyses, Mc Nemar chi square test and Spearman's correlation tests were used. There was a significant positive correlation between fibrosis in biopsy and the level of fibrosis in FibroTest in patients with hepatitis B virus (HBV) (rho: 0.67, P < 0.0001). However, no significant correlation was determined between the activity in biopsy and the degree of activity in ActiTest (rho: 0.29, P < 0.05). No significant correlation was determined between both fibrosis and activity established in biopsy and the results of FibroTest and ActiTest in the group of patients with hepatitis C virus (HCV) (rho: 0.22, P < 0.05 and rho: 0.15, P < 0.05, respectively). Our results suggest that novel and safer noninvasive biochemical tests are needed as an alternative to histopathology in patients infected with HBV and HCV. Consequently, we believe that liver biopsy maintains its place as a gold standard in determining the histopathological condition of the liver.

  15. Aircraft and ground vehicle friction correlation test results obtained under winter runway conditions during joint FAA/NASA Runway Friction Program

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.; Vogler, William A.; Baldasare, Paul

    1988-01-01

    Aircraft and ground vehicle friction data collected during the Joint FAA/NASA Runway Friction Program under winter runway conditions are discussed and test results are summarized. The relationship between the different ground vehicle friction measurements obtained on compacted snow- and ice-covered conditions is defined together with the correlation to aircraft tire friction performance under similar runway conditions.

  16. Toward Using Confidence Intervals to Compare Correlations

    ERIC Educational Resources Information Center

    Zou, Guang Yong

    2007-01-01

    Confidence intervals are widely accepted as a preferred way to present study results. They encompass significance tests and provide an estimate of the magnitude of the effect. However, comparisons of correlations still rely heavily on significance testing. The persistence of this practice is caused primarily by the lack of simple yet accurate…

  17. ASSOCIATIONS BETWEEN THREE CLINICAL ASSESSMENT TOOLS FOR POSTURAL STABILITY

    PubMed Central

    Saxion, Casie E.; Cameron, Kenneth L.; Gerber, J. Parry

    2010-01-01

    Study Design: Clinical Measurement, Correlation, Reliability Objectives: To assess the relationship between the Single Leg Balance (SLB), modified Balance Error Scoring System (mBESS), and modified Star Excursion Balance (mSEBT) tests and secondarily to assess inter-rater and test-retest reliability of these tests. Background: Ankle sprains often result in chronic instability and dysfunction. Several clinical tests assess postural deficits as a potential cause of this dysfunction; however, limited information exists pertaining to the relationship that these tests have with one another. Methods: Two independent examiners measured the performance of 34 healthy participants completing the SLB Test, mBESS test, and mSEBT at two different time periods. The relationship between tests was assessed using the Pearson Correlation and Fisher's Exact Tests. Inter-rater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Kappa statistics. Results: A significant correlation (r = -0.35) was observed between the mSEBT and the mBESS. Fisher's Exact Test showed a significant association between the SLB Test and mBESS (P = .048), but no association between the SLB and mSEBT (P = 1.000). Inter-rater reliability was excellent for the mSEBT and fair for the mBESS (ICCs of .91 and .61 respectively). Excellent agreement was observed between raters for the SLB test (k = 1.00). Test-retest reliability was excellent for the mSEBT (ICC = 0.98) and fair for the mBESS (ICC = 0.74). There was poor test-retest agreement for the SLB test (k = .211). Conclusion: There was a significant relationship observed between the SLB Test, mBESS test, and mSEBT: however; strength of association measures showed limited overlap between these tests. This suggests that these tests are interrelated but may not assess equal components of postural stability. PMID:21589668

  18. Correlation between standard Charpy and sub-size Charpy test results of selected steels in upper shelf region

    NASA Astrophysics Data System (ADS)

    Konopík, P.; Džugan, J.; Bucki, T.; Rzepa, S.; Rund, M.; Procházka, R.

    2017-02-01

    Absorbed energy obtained from impact Charpy tests is one of the most important values in many applications, for example in residual lifetime assessment of components in service. Minimal absorbed energy is often the value crucial for extending components service life, e.g. turbines, boilers and steam lines. Using a portable electric discharge sampling equipment (EDSE), it is possible to sample experimental material non-destructively and subsequently produce mini-Charpy specimens. This paper presents a new approach in correlation from sub-size to standard Charpy test results.

  19. Prediction of clinical response to drugs in ovarian cancer using the chemotherapy resistance test (CTR-test).

    PubMed

    Kischkel, Frank Christian; Meyer, Carina; Eich, Julia; Nassir, Mani; Mentze, Monika; Braicu, Ioana; Kopp-Schneider, Annette; Sehouli, Jalid

    2017-10-27

    In order to validate if the test result of the Chemotherapy Resistance Test (CTR-Test) is able to predict the resistances or sensitivities of tumors in ovarian cancer patients to drugs, the CTR-Test result and the corresponding clinical response of individual patients were correlated retrospectively. Results were compared to previous recorded correlations. The CTR-Test was performed on tumor samples from 52 ovarian cancer patients for specific chemotherapeutic drugs. Patients were treated with monotherapies or drug combinations. Resistances were classified as extreme (ER), medium (MR) or slight (SR) resistance in the CTR-Test. Combination treatment resistances were transformed by a scoring system into these classifications. Accurate sensitivity prediction was accomplished in 79% of the cases and accurate prediction of resistance in 100% of the cases in the total data set. The data set of single agent treatment and drug combination treatment were analyzed individually. Single agent treatment lead to an accurate sensitivity in 44% of the cases and the drug combination to 95% accuracy. The detection of resistances was in both cases to 100% correct. ROC curve analysis indicates that the CTR-Test result correlates with the clinical response, at least for the combination chemotherapy. Those values are similar or better than the values from a publication from 1990. Chemotherapy resistance testing in vitro via the CTR-Test is able to accurately detect resistances in ovarian cancer patients. These numbers confirm and even exceed results published in 1990. Better sensitivity detection might be caused by a higher percentage of drug combinations tested in 2012 compared to 1990. Our study confirms the functionality of the CTR-Test to plan an efficient chemotherapeutic treatment for ovarian cancer patients.

  20. Associations between physical function, dual-task performance and cognition in patients with mild Alzheimer's disease.

    PubMed

    Sobol, Nanna Aue; Hoffmann, Kristine; Vogel, Asmus; Lolk, Annette; Gottrup, Hanne; Høgh, Peter; Hasselbalch, Steen G; Beyer, Nina

    2016-11-01

    Alzheimer's disease (AD) causes a gradual decline in cognition, limitations of dual-tasking and physical function leading to total dependence. Hence, information about the interaction between physical function, dual-task performance and cognition may lead to new treatment strategies with the purpose of preserving function and quality of life. The objective of this study was to investigate the associations between physical function, dual-task performance and cognition in community-dwelling patients with mild AD. Baseline results from 185 participants (50-90 years old) in the single blinded multicenter RCT 'ADEX' (Alzheimer's disease: the effect of physical exercise) were used. Assessments included tests of physical function: 400-m walk test, 10-m walk test, Timed Up and Go test and 30-s chair stand test; dual-task performance, i.e., 10-m walk while counting backwards from 50 or naming the months backwards; and cognition, i.e., Mini Mental State Examination, Symbol Digit Modalities Test, the Stroop Color and Word Test, and Lexical verbal fluency test. Results in the 30-s chair stand test correlated significantly with all tests of cognition (r = .208-.242) while the other physical function tests only randomly correlated with tests of cognition. Results in the dual-task counting backwards correlated significantly with results in all tests of cognition (r = .259-.388), which accounted for 7%-15% of the variation indicating that a faster time to complete dual-task performance was associated with better cognitive performance. The evidence of the associations between physical function, dual-task performance and cognition is important when creating new rehabilitation interventions to patients with mild AD.

  1. Inference for High-dimensional Differential Correlation Matrices *

    PubMed Central

    Cai, T. Tony; Zhang, Anru

    2015-01-01

    Motivated by differential co-expression analysis in genomics, we consider in this paper estimation and testing of high-dimensional differential correlation matrices. An adaptive thresholding procedure is introduced and theoretical guarantees are given. Minimax rate of convergence is established and the proposed estimator is shown to be adaptively rate-optimal over collections of paired correlation matrices with approximately sparse differences. Simulation results show that the procedure significantly outperforms two other natural methods that are based on separate estimation of the individual correlation matrices. The procedure is also illustrated through an analysis of a breast cancer dataset, which provides evidence at the gene co-expression level that several genes, of which a subset has been previously verified, are associated with the breast cancer. Hypothesis testing on the differential correlation matrices is also considered. A test, which is particularly well suited for testing against sparse alternatives, is introduced. In addition, other related problems, including estimation of a single sparse correlation matrix, estimation of the differential covariance matrices, and estimation of the differential cross-correlation matrices, are also discussed. PMID:26500380

  2. Fuel effects on soot formation in turbojet engines. Final report, September 15, 1983-March 14, 1985

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gill, R.J.; Olson, D.B.

    1985-08-01

    The results of tests on how fuel composition affects the performance of three Navy aircraft engine combustors, the TF30, T56, and T53, were analyzed. The objective of this analysis was to identify which fuel property best correlated with the smoke-related measurements: radiation flux, liner temperature rise, smoke number, and smoke emissions. The effects of fuel composition were investigated by using a series of ten Naval Air Propulsion Center jet fuels with various properties, such as hydrogen contents of 12.83 to 13.82% and total aromatic hydrocarbon contents of 15.9 to 28.5%. Several laboratory combustion characteristics of these fuels were measured andmore » these characteristics were used in analysis. Altogether, 15 fuel parameters were used to correlate the 45 combustor test results. The reported operating conditions of the tests, such as inlet air pressure, inlet air temperature, or fuel/air ratio, were also used as correlating parameters to determine whether variations in these variables, nearly constant for individual tests, also affected the smoke-related test results.« less

  3. Correlation and evaluation of inplane stability characteristics for an advanced bearingless main rotor

    NASA Technical Reports Server (NTRS)

    Weller, W. H.

    1983-01-01

    A program of experimental and analytical research was performed to demonstrate the degree of correlation achieved between measured and computed rotor inplane stability characteristics. The experimental data were obtained from hover and wind tunnel tests of a scaled bearingless main rotor model. Both isolated rotor and free-hub conditions were tested. Test parameters included blade built-in cone and sweep angles; rotor inplane structural stiffness and damping; pitch link stiffness and location; and fuselage damping, inertia, and natural frequency. Analytical results for many test conditions were obtained. In addition, the analytical and experimental results were examined to ascertain the effects of the test parameters on rotor ground and air resonance stability. The results from this program are presented herein in tabular and graphical form.

  4. [The Manifestation of the Anxiety during Fear Conditioning in Wistar Rats].

    PubMed

    Pavlova, I V; Rysakova, M P

    2015-01-01

    In order to identify the correlation between anxiety and conditioned fear, the behavior of the same male Wistar rats was compared in three anxiety tests (open field, light-dark box and elevated plus-maze) and in Pavlovian auditory fear conditioning paradigm using correlation, factor and variance analyses. The correlation between anxiety/bravery and locomotion indexes in different tests was not revealed. Positive correlations between grooming, urinations and defecations, rearing in three tests were revealed. These data suggest that animals reacted to various tests differently, resulting, apparently in the emergence of different anxiety levels, specific for each test. Vegetative reactions, inclination to exploration and substituting behavior were more stable characteristics of rats. Anxiety behavior in elevated plus-maze correlated to freezing response to context after fear conditioning, while high-anxiety rats had higher level of freezing to context than low-anxiety rats. The higher freezing response to sound after fear conditioning was found in rats with middle locomotor activity in open field. Conditioned fear to the context and to the sound was associated with different forms of rat anxiety during different tests.

  5. THE RELATIONSHIP BETWEEN VARIOUS MODES OF SINGLE LEG POSTURAL CONTROL ASSESSMENT

    PubMed Central

    Schmitz, Randy

    2012-01-01

    Purpose/Background: While various techniques have been developed to assess the postural control system, little is known about the relationship between single leg static and functional balance. The purpose of the current study was to determine the relationship between the performance measures of several single leg postural stability tests. Methods: Forty six recreationally active college students (17 males, 29 females, 21±3 yrs, 173±10 cm) performed six single leg tests in a counterbalanced order: 1) Firm Surface-Eyes Open, 2) Firm Surface-Eyes Closed, 3) Multiaxial Surface-Eyes Open, 4) Multiaxial Surface-Eyes Closed, 5) Star Excursion Balance Test (posterior medial reach), 6) Single leg Hop-Stabilization Test. Bivariate correlations were conducted between the six outcome variables. Results: Mild to moderate correlations existed between the static tests. No significant correlations existed involving either of the functional tests. Conclusions: The results indicate that while performance of static balance tasks are mildly to moderately related, they appear to be unrelated to functional reaching or hopping movements, supporting the utilization of a battery of tests to determine overall postural control performance. Level of Evidence: 3b PMID:22666640

  6. Influence of body mass index on the growth hormone response to provocative testing in short children without growth hormone deficiency.

    PubMed

    Lee, Jieun; Yoon, Juyoung; Kang, Min Jae; Lee, Young Ah; Lee, Seong Yong; Shin, Choong Ho; Yang, Sei Won

    2013-09-01

    Obesity and its related factors are known to suppress the secretion of growth hormone (GH). We aimed to evaluate the influence of body mass index (BMI) on the peak GH response to provocative testing in short children without GH deficiency. We conducted a retrospective review of medical records of 88 children (2-15 yr old) whose height was less than 3 percentile for one's age and sex, with normal results (peak GH level > 10 ng/mL) of GH provocative testing with clonidine and dopamine. Peak stimulated GH level, height, weight, pubertal status and serum IGF-1 level were measured. Univariate analysis showed that the BMI standard deviation score (SDS) correlated negatively with the natural log (ln) of the peak stimulated GH level (ln peak GH). BMI SDS did not correlate significantly with sex, age, pubertal status, or ln IGF-1 level. BMI SDS correlated negatively with ln peak GH level induced by clonidine but not by dopamine. In stepwise multivariate regression analysis, BMI SDS was the only significant predictor of ln peak GH level in the combination of tests and the clonidine test, but not in the dopamine test. In children without GH deficiency, BMI SDS correlates negatively with the peak GH level. BMI SDS should be included in the analysis of the results of GH provocation tests, especially tests with clonidine.

  7. Evaluation of Fitness and the Balance Levels of Children with a Diagnosis of Juvenile Idiopathic Arthritis: A Pilot Study

    PubMed Central

    Maggio, Maria Cristina; Corsello, Giovanni; Messina, Giuseppe; Iovane, Angelo; Palma, Antonio

    2017-01-01

    Background: Juvenile idiopathic arthritis is a main cause of physical disability and has high economic costs for society. The purpose of this study was to assess the fitness levels and the postural and balance deficits with a specific test battery. Methods: Fifty-six subjects were enrolled in this study. Thirty-nine healthy subjects were included in the control group and seventeen in the juvenile idiopathic arthritis group. All subjects were evaluated using a posturography system. The fitness level was evaluated with a battery of tests (Abalakov test, sit-up test, hand grip test, backsaver sit and reach, the toe touch test). An unpaired t-test was used to determine differences. Pearson’s correlation coefficient was used to evaluate the correlation between the tests. Results: The battery of tests demonstrated that subjects in the juvenile idiopathic arthritis group have lower fitness levels compared to the control group. The juvenile idiopathic arthritis group showed low postural control with respect to the control group. Pearson analysis of the juvenile idiopathic arthritis group data showed significant correlations between variables. Pearson’s results from the control group data showed a similar trend. Conclusions: The results suggest that the battery of tests used could be an appropriate tool. However, we highlight that these conclusions need to be supported by other studies with a larger population scale. PMID:28753965

  8. Evaluation of Fitness and the Balance Levels of Children with a Diagnosis of Juvenile Idiopathic Arthritis: A Pilot Study.

    PubMed

    Patti, Antonino; Maggio, Maria Cristina; Corsello, Giovanni; Messina, Giuseppe; Iovane, Angelo; Palma, Antonio

    2017-07-19

    Background: Juvenile idiopathic arthritis is a main cause of physical disability and has high economic costs for society. The purpose of this study was to assess the fitness levels and the postural and balance deficits with a specific test battery. Methods: Fifty-six subjects were enrolled in this study. Thirty-nine healthy subjects were included in the control group and seventeen in the juvenile idiopathic arthritis group. All subjects were evaluated using a posturography system. The fitness level was evaluated with a battery of tests (Abalakov test, sit-up test, hand grip test, backsaver sit and reach, the toe touch test). An unpaired t -test was used to determine differences. Pearson's correlation coefficient was used to evaluate the correlation between the tests. Results: The battery of tests demonstrated that subjects in the juvenile idiopathic arthritis group have lower fitness levels compared to the control group. The juvenile idiopathic arthritis group showed low postural control with respect to the control group. Pearson analysis of the juvenile idiopathic arthritis group data showed significant correlations between variables. Pearson's results from the control group data showed a similar trend. Conclusions: The results suggest that the battery of tests used could be an appropriate tool. However, we highlight that these conclusions need to be supported by other studies with a larger population scale.

  9. Validation of a clinical assessment of spectral-ripple resolution for cochlear implant users.

    PubMed

    Drennan, Ward R; Anderson, Elizabeth S; Won, Jong Ho; Rubinstein, Jay T

    2014-01-01

    Nonspeech psychophysical tests of spectral resolution, such as the spectral-ripple discrimination task, have been shown to correlate with speech-recognition performance in cochlear implant (CI) users. However, these tests are best suited for use in the research laboratory setting and are impractical for clinical use. A test of spectral resolution that is quicker and could more easily be implemented in the clinical setting has been developed. The objectives of this study were (1) To determine whether this new clinical ripple test would yield individual results equivalent to the longer, adaptive version of the ripple-discrimination test; (2) To evaluate test-retest reliability for the clinical ripple measure; and (3) To examine the relationship between clinical ripple performance and monosyllabic word recognition in quiet for a group of CI listeners. Twenty-eight CI recipients participated in the study. Each subject was tested on both the adaptive and the clinical versions of spectral ripple discrimination, as well as consonant-nucleus-consonant word recognition in quiet. The adaptive version of spectral ripple used a two-up, one-down procedure for determining spectral ripple discrimination threshold. The clinical ripple test used a method of constant stimuli, with trials for each of 12 fixed ripple densities occurring six times in random order. Results from the clinical ripple test (proportion correct) were then compared with ripple-discrimination thresholds (in ripples per octave) from the adaptive test. The clinical ripple test showed strong concurrent validity, evidenced by a good correlation between clinical ripple and adaptive ripple results (r = 0.79), as well as a correlation with word recognition (r = 0.7). Excellent test-retest reliability was also demonstrated with a high test-retest correlation (r = 0.9). The clinical ripple test is a reliable nonlinguistic measure of spectral resolution, optimized for use with CI users in a clinical setting. The test might be useful as a diagnostic tool or as a possible surrogate outcome measure for evaluating treatment effects in hearing.

  10. Reliability and Validity of a New Test of Agility and Skill for Female Amateur Soccer Players

    PubMed Central

    Kutlu, Mehmet; Yapici, Hakan; Yilmaz, Abdullah

    2017-01-01

    Abstract The aim of this study was to evaluate the Agility and Skill Test, which had been recently developed to assess agility and skill in female athletes. Following a 10 min warm-up, two trials to test the reliability and validity of the test were conducted one week apart. Measurements were collected to compare soccer players’ physical performance in a 20 m sprint, a T-Drill test, the Illinois Agility Run Test, change-of-direction and acceleration, as well as agility and skill. All tests were completed following the same order. Thirty-four amateur female soccer players were recruited (age = 20.8 ± 1.9 years; body height = 166 ± 6.9 cm; body mass = 55.5 ± 5.8 kg). To determine the reliability and usefulness of these tests, paired sample t-tests, intra-class correlation coefficients, typical error, coefficient of variation, and differences between the typical error and smallest worthwhile change statistics were computed. Test results showed no significant differences between the two sessions (p > 0.01). There were higher intra-class correlations between the test and retest values (r = 0.94–0.99) for all tests. Typical error values were below the smallest worthwhile change, indicating ‘good’ usefulness for these tests. A near perfect Pearson correlation between the Agility and Skill Test (r = 0.98) was found, and there were moderate-to-large levels of correlation between the Agility and Skill Test and other measures (r = 0.37 to r = 0.56). The results of this study suggest that the Agility and Skill Test is a reliable and valid test for female soccer players and has significant value for assessing the integrative agility and skill capability of soccer players. PMID:28469760

  11. Test anxiety in medical school is unrelated to academic performance but correlates with an effort/reward imbalance.

    PubMed

    Hahn, Henry; Kropp, Peter; Kirschstein, Timo; Rücker, Gernot; Müller-Hilke, Brigitte

    2017-01-01

    During their early years at medical school, students repeatedly criticize their workload, time constraints and test associated stress. At the same time, depressiveness and anxiety among first and second year medical students are on the rise. We therefore hypothesized that test anxiety may be related to depressiveness and considered cognitive and academic performances as confounders for the former and psychosocial distress for the latter. A whole class of 200 second year students was invited to participate in the study. Anxiety as a trait, depressiveness, crystallized intelligence, verbal fluency and psychosocial distress were assessed using validated tests and questionnaires. Acute state anxiety and sympathetic stress parameters were measured in real life situations immediately before an oral and a written exam and paired tests were used to compare the individual anxieties at the various time points. Previous academic performances were self-reported, the results of the impending exams were monitored. Finally, correlations were performed to test for interrelatedness between academic performances and the various personal, cognitive and psychosocial factors. Acute test anxiety did not correlate with depressiveness nor did it correlate with previous nor impending academic performances nor any of the expected confounders on academic performance. However both, depressiveness and test anxiety strongly correlated with the perceived imbalance between efforts spent and rewards received. Moreover, anxiety as a trait not only correlated with acute state anxiety before an exam but was also significantly correlated to the feeling of over-commitment. Depressiveness during the early years of medical school seems unrelated to test anxiety and academic performance. Instead, it strongly correlated with the psychosocial distress emanating from attending medical school and points at a perceived imbalance between efforts spent and rewards received.

  12. Applying standardized uptake values in gallium-67-citrate single-photon emission computed tomography/computed tomography studies and their correlation with blood test results in representative organs.

    PubMed

    Toriihara, Akira; Daisaki, Hiromitsu; Yamaguchi, Akihiro; Yoshida, Katsuya; Isogai, Jun; Tateishi, Ukihide

    2018-05-21

    Recently, semiquantitative analysis using standardized uptake value (SUV) has been introduced in bone single-photon emission computed tomography/computed tomography (SPECT/CT). Our purposes were to apply SUV-based semiquantitative analytic method for gallium-67 (Ga)-citrate SPECT/CT and to evaluate correlation between SUV of physiological uptake and blood test results in representative organs. The accuracy of semiquantitative method was validated using an National Electrical Manufacturers Association body phantom study (radioactivity ratio of sphere : background=4 : 1). Thereafter, 59 patients (34 male and 25 female; mean age, 66.9 years) who had undergone Ga-citrate SPECT/CT were retrospectively enrolled in the study. A mean SUV of physiological uptake was calculated for the following organs: the lungs, right atrium, liver, kidneys, spleen, gluteal muscles, and bone marrow. The correlation between physiological uptakes and blood test results was evaluated using Pearson's correlation coefficient. The phantom study revealed only 1% error between theoretical and actual SUVs in the background, suggesting the sufficient accuracy of scatter and attenuation corrections. However, a partial volume effect could not be overlooked, particularly in small spheres with a diameter of less than 28 mm. The highest mean SUV was observed in the liver (range: 0.44-4.64), followed by bone marrow (range: 0.33-3.60), spleen (range: 0.52-2.12), and kidneys (range: 0.42-1.45). There was no significant correlation between hepatic uptake and liver function, renal uptake and renal function, or bone marrow uptake and blood cell count (P>0.05). The physiological uptake in Ga-citrate SPECT/CT can be represented as SUVs, which are not significantly correlated with corresponding blood test results.

  13. Single-Leg Hop Test Performance and Isokinetic Knee Strength After Anterior Cruciate Ligament Reconstruction in Athletes

    PubMed Central

    Sueyoshi, Ted; Nakahata, Akihiro; Emoto, Gen; Yuasa, Tomoki

    2017-01-01

    Background: Isokinetic strength and hop tests are commonly used to assess athletes’ readiness to return to sport after knee surgery. Purpose/Hypothesis: The purpose of this study was to investigate the results of single-leg hop and isokinetic knee strength testing in athletes who underwent anterior cruciate ligament reconstruction (ACLR) upon returning to sport participation as well as to study the correlation between these 2 test batteries. The secondary purpose was to compare the test results by graft type (patellar tendon or hamstring). It was hypothesized that there would be no statistically significant limb difference in either isokinetic knee strength or single-leg hop tests, that there would be a moderate to strong correlation between the 2 test batteries, and that there would be no significant difference between graft types. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twenty-nine high school and collegiate athletes who underwent ACLR participated in this study. At the time of return to full sport participation, a series of hop tests and knee extension/flexion isokinetic strength measurements were conducted. The results were analyzed using analysis of variance and Pearson correlation (r). Results: The timed 6-m hop test was the only hop test that showed a significant difference between the involved and uninvolved limbs (2.3 and 2.2 seconds, respectively; P = .02). A significant difference between limbs in knee strength was found for flexion peak torque/body weight at 180 deg/s (P = .03), flexion total work/body weight at 180 deg/s (P = .04), and flexion peak torque/body weight at 300 deg/s (P = .03). The strongest correlation between the hop tests and knee strength was found between the total distance of the hop tests and flexion total work/body weight at 300 deg/s (r = 0.69) and between the timed 6-m hop test and flexion peak torque/body weight at 300 deg/s (r = –0.54). There was no statistically significant difference in hop test performance or isokinetic knee strength between graft types. Conclusion: The single-leg hop tests and isokinetic strength measurements were both useful for a bilateral comparison of knee functional performance and strength. Knee flexion strength deficits and flexion-to-extension ratios seemed to be correlated with single-leg hop test performance. There was no difference in postoperative hop test performance or knee strength according to graft type. PMID:29164167

  14. VALIDATION OF A CLINICAL ASSESSMENT OF SPECTRAL RIPPLE RESOLUTION FOR COCHLEAR-IMPLANT USERS

    PubMed Central

    Drennan, Ward. R.; Anderson, Elizabeth S.; Won, Jong Ho; Rubinstein, Jay T.

    2013-01-01

    Objectives Non-speech psychophysical tests of spectral resolution, such as the spectral-ripple discrimination task, have been shown to correlate with speech recognition performance in cochlear implant (CI) users (Henry et al., 2005; Won et al. 2007, 2011; Drennan et al. 2008; Anderson et al. 2011). However, these tests are best suited for use in the research laboratory setting and are impractical for clinical use. A test of spectral resolution that is quicker and could more easily be implemented in the clinical setting has been developed. The objectives of this study were 1) To determine if this new clinical ripple test would yield individual results equivalent to the longer, adaptive version of the ripple discrimination test; 2) To evaluate test-retest reliability for the clinical ripple measure; and 3) To examine the relationship between clinical ripple performance and monosyllabic word recognition in quiet for a group of CI listeners. Design Twenty-eight CI recipients participated in the study. Each subject was tested on both the adaptive and the clinical versions of spectral ripple discrimination, as well as CNC word recognition in quiet. The adaptive version of spectral ripple employed a 2-up, 1-down procedure for determining spectral ripple discrimination threshold. The clinical ripple test used a method of constant stimuli, with trials for each of 12 fixed ripple densities occurring six times in random order. Results from the clinical ripple test (proportion correct) were then compared to ripple discrimination thresholds (in ripples per octave) from the adaptive test. Results The clinical ripple test showed strong concurrent validity, evidenced by a good correlation between clinical ripple and adaptive ripple results (r=0.79), as well as a correlation with word recognition (r = 0.7). Excellent test-retest reliability was also demonstrated with a high test-retest correlation (r = 0.9). Conclusions The clinical ripple test is a reliable non-linguistic measure of spectral resolution, optimized for use with cochlear implant users in a clinical setting. The test might be useful as a diagnostic tool or as a possible surrogate outcome measure for evaluating treatment effects in hearing. PMID:24552679

  15. Spatial abilities, Earth science conceptual understanding, and psychological gender of university non-science majors

    NASA Astrophysics Data System (ADS)

    Black, Alice A. (Jill)

    Research has shown the presence of many Earth science misconceptions and conceptual difficulties that may impede concept understanding, and has also identified a number of categories of spatial ability. Although spatial ability has been linked to high performance in science, some researchers believe it has been overlooked in traditional education. Evidence exists that spatial ability can be improved. This correlational study investigated the relationship among Earth science conceptual understanding, three types of spatial ability, and psychological gender, a self-classification that reflects socially-accepted personality and gender traits. A test of Earth science concept understanding, the Earth Science Concepts (ESC) test, was developed and field tested from 2001 to 2003 in 15 sections of university classes. Criterion validity was .60, significant at the .01 level. Spearman/Brown reliability was .74 and Kuder/Richardson reliability was .63. The Purdue Visualization of Rotations (PVOR) (mental rotation), the Group Embedded Figures Test (GEFT) (spatial perception), the Differential Aptitude Test: Space Relations (DAT) (spatial visualization), and the Bem Inventory (BI) (psychological gender) were administered to 97 non-major university students enrolled in undergraduate science classes. Spearman correlations revealed moderately significant correlations at the .01 level between ESC scores and each of the three spatial ability test scores. Stepwise regression analysis indicated that PVOR scores were the best predictor of ESC scores, and showed that spatial ability scores accounted for 27% of the total variation in ESC scores. Spatial test scores were moderately or weakly correlated with each other. No significant correlations were found among BI scores and other test scores. Scantron difficulty analysis of ESC items produced difficulty ratings ranging from 33.04 to 96.43, indicating the percentage of students who answered incorrectly. Mean score on the ESC was 34%, indicating that the non-majors tested exhibited many Earth science misconceptions and conceptual difficulties. A number of significant results were found when independent t-tests and correlations were conducted among test scores and demographic variables. The number of previous university Earth science courses was significantly related to ESC scores. Preservice elementary/middle majors differed significantly in several ways from other non-majors, and several earlier results were not supported. Results of this study indicate that an important opportunity may exist to improve Earth science conceptual understanding by focusing on spatial ability, a cognitive ability that has heretofore not been directly addressed in schools.

  16. CORRELATION BETWEEN METAL-CERAMIC BOND STRENGTH AND COEFFICIENT OF LINEAR THERMAL EXPANSION DIFFERENCE

    PubMed Central

    Lopes, Stella Crosara; Pagnano, Valéria Oliveira; Rollo, João Manuel Domingos de Almeida; Leal, Mônica Barbosa; Bezzon, Osvaldo Luiz

    2009-01-01

    The purpose of this study was to evaluate the metal-ceramic bond strength (MCBS) of 6 metal-ceramic pairs (2 Ni-Cr alloys and 1 Pd-Ag alloy with 2 dental ceramics) and correlate the MCBS values with the differences between the coefficients of linear thermal expansion (CTEs) of the metals and ceramics. Verabond (VB) Ni-Cr-Be alloy, Verabond II (VB2), Ni-Cr alloy, Pors-on 4 (P), Pd-Ag alloy, and IPS (I) and Duceram (D) ceramics were used for the MCBS test and dilatometric test. Forty-eight ceramic rings were built around metallic rods (3.0 mm in diameter and 70.0 mm in length) made from the evaluated alloys. The rods were subsequently embedded in gypsum cast in order to perform a tensile load test, which enabled calculating the CMBS. Five specimens (2.0 mm in diameter and 12.0 mm in length) of each material were made for the dilatometric test. The chromel-alumel thermocouple required for the test was welded into the metal test specimens and inserted into the ceramics. ANOVA and Tukey's test revealed significant differences (p=0.01) for the MCBS test results (MPa), with PI showing higher MCBS (67.72) than the other pairs, which did not present any significant differences. The CTE (10-6 °C-1) differences were: VBI (0.54), VBD (1.33), VB2I (-0.14), VB2D (0.63), PI (1.84) and PD (2.62). Pearson's correlation test (r=0.17) was performed to evaluate of correlation between MCBS and CTE differences. Within the limitations of this study and based on the obtained results, there was no correlation between MCBS and CTE differences for the evaluated metal-ceramic pairs. PMID:19274398

  17. Diagnosing TB infection in children: analysis of discordances using in vitro tests and the tuberculin skin test.

    PubMed

    Altet-Gómez, N; De Souza-Galvao, M; Latorre, I; Milà, C; Jiménez, M A; Solsona, J; Cantos, A; Zamora, J J; Ruiz-Manzano, J; Ausina, V; Domínguez, J

    2011-05-01

    The aim of the present study was to compare the performance of the interferon (IFN)-γ tests (QuantiFERON®-TB Gold In-Tube (QFT-G-IT) and T-SPOT®.TB) with the tuberculin skin test (TST) in diagnosing tuberculosis (TB) infection in children, and to analyse discordant results. This was a prospective study including 98 children from contact-tracing studies and 68 children with TST indurations ≥ 5 mm recruited during public health screenings. Positive IFN-γ tests results were associated with risk of exposure (p<0.0001). T-SPOT.TB was positive in 11 (78.6%) out of 14 cases with active TB and QFT-G-IT in nine (64.3%) out of 14 cases. Sensitised T-cells against Mycobacterium avium were detected in six out of 12 children not vaccinated with bacille Calmette-Guérin (BCG), a TST induration 5-9 mm in diameter and both IFN-γ tests negative. In concordant IFN-γ tests results, a positive correlation was found (p = 0.0001) between the number of responding cells and the amount of IFN-γ released. However, in discordant IFN-γ tests results this correlation was negative (p = 0.371): an increase in the number of spot-forming cells correlated with a decrease in the amount of IFN-γ released. The use of IFN-γ tests is helpful for the diagnosis of TB infection, avoiding cross-reactions with BCG immunisation and nontuberculous mycobacterial infections. The analysis of highly discordant results requires further investigation to elucidate possible clinical implications.

  18. Correlation of Fin Buffet Pressures on an F/A-18 with Scaled Wind-Tunnel Measurements

    NASA Technical Reports Server (NTRS)

    Moses, Robert W.; Shah, Gautam H.

    1999-01-01

    Buffeting is an aeroelastic phenomenon occurring at high angles of attack that plagues high performance aircraft, especially those with twin vertical tails. Previous wind-tunnel and flight tests were conducted to characterize the buffet loads on the vertical tails by measuring surface pressures, bending moments, and accelerations. Following these tests, buffeting responses were computed using the measured buffet pressures and compared to the measured buffeting responses. The calculated results did not match the measured data because the assumed spatial correlation of the buffet pressures was not correct. A better understanding of the partial (spatial) correlation of the differential buffet pressures on the tail was necessary to improve the buffeting predictions. Several wind-tunnel investigations were conducted for this purpose. When compared, the results of these tests show that the partial correlation scales with flight conditions. One of the remaining questions is whether the wind-tunnel data is consistent with flight data. Presented herein, cross-spectra and coherence functions calculated from pressures that were measured on the High Alpha Research Vehicle indicate that the partial correlation of the buffet pressures in flight agrees with the partial correlation observed in the wind tunnel.

  19. Correlation of Gerkin, Queen's College, George, and Jackson methods in estimating maximal oxygen consumption.

    PubMed

    Heydari, Payam; Varmazyar, Sakineh; Variani, Ali Safari; Hashemi, Fariba; Ataei, Seyed Sajad

    2017-10-01

    Test of maximal oxygen consumption is the gold standard for measuring cardio-pulmonary fitness. This study aimed to determine correlation of Gerkin, Queen's College, George, and Jackson methods in estimating maximal oxygen consumption, and demographic factors affecting maximal oxygen consumption. This descriptive cross-sectional study was conducted in a census of medical emergency students (n=57) in Qazvin University of Medical Sciences in 2016. The subjects firstly completed the General Health Questionnaire (PAR-Q) and demographic characteristics. Then eligible subjects were assessed using exercise tests of Gerkin treadmill, Queen's College steps and non-exercise George, and Jackson. Data analysis was carried out using independent t-test, one way analysis of variance and Pearson correlation in the SPSS software. The mean age of participants was 21.69±4.99 years. The mean of maximal oxygen consumption using Gerkin, Queen's College, George, and Jackson tests was 4.17, 3.36, 3.64, 3.63 liters per minute, respectively. Pearson statistical test showed a significant correlation among fours tests. George and Jackson tests had the greatest correlation (r=0.85, p>0.001). Results of tests of one-way analysis of variance and t-test showed a significant relationship between independent variable of weight and height in four tests, and dependent variable of maximal oxygen consumption. Also, there was a significant relationship between variable of body mass index in two tests of Gerkin and Queen's College and variable of exercise hours per week with the George and Jackson tests (p>0.001). Given the obtained correlation, these tests have the potential to replace each other as necessary, so that the non-exercise Jackson test can be used instead of the Gerkin test.

  20. Matrix Metalloproteinase 9 Testing in Dry Eye Disease Using a Commercially Available Point-of-Care Immunoassay.

    PubMed

    Messmer, Elisabeth M; von Lindenfels, Victoria; Garbe, Alexandra; Kampik, Anselm

    2016-11-01

    To measure matrix metalloproteinase 9 (MMP-9) in the tear film of patients with dry eye disease (DED) compared with controls and to correlate clinical findings. In a prospective study, 101 patients and controls underwent MMP-9 testing of the tear film. Thereafter, they were evaluated for symptoms and signs of DED. Included patients were those who showed 3 of the following 4 dry eye criteria: ocular surface disease index (OSDI) score of more than 12, tear film break-up time (TBUT) of 10 seconds or less, Schirmer test results without anesthesia of less than 10 mm/5 minutes, and corneal staining results of 1 or more. Fifty-four healthy eyes and 47 eyes fulfilling diagnostic criteria for DED of various levels of severity were included in this study. The tear film was analyzed for MMP-9 by a commercially available test (InflammaDry; Rapid Pathogen Screening, Inc, Sarasota, FL) detecting MMP-9 levels of more than 40 ng/ml. Symptoms and signs of DED were evaluated using the OSDI questionnaire, TBUT, conjunctival and corneal staining, Schirmer test results without anesthesia, and meibomian gland examination. These findings were correlated to results of the MMP-9 test in tears. Positive MMP-9 results in tears. In 19 of 47 patients confirmed with dry eye (40.4%) and in 3 of 54 controls (5.6%), the MMP-9 results were positive. This difference was statistically significant (P < 0.001). Thus, the MMP-9 results indicated a clinically significant inflammation in 40% of dry eye patients. Positive results correlated well with subjective symptoms of DED evaluated by OSDI (P = 0.001), TBUT of less than 5 seconds (P < 0.013), Schirmer test results (P < 0.001), conjunctival staining (P < 0.001), and corneal staining (P = 0.007). Moreover, MMP-9 results correlated with the number of obstructed meibomian ducts (P = 0.005) and a pathologic meibomian gland secretion (P = 0.001). The MMP-9 results were increased significantly in women (P < 0.001) and in patients with autoimmune disease (P = 0.005), especially Sjögren's syndrome (P = 0.001) and thyroid disease (P = 0.012). Matrix metalloproteinase 9 testing in DED is a valuable new diagnostic tool. It correlated well with other dry eye tests and identified the presence of ocular surface inflammation in 40% of confirmed dry eye patients. It may be especially helpful to identify patients with ocular surface inflammation and autoimmune disease and may facilitate the decision to institute anti-inflammatory treatment in these patients. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  1. Associations among methane emission traits measured in the feedlot and in respiration chambers in Angus cattle bred to vary in feed efficiency.

    PubMed

    Herd, R M; Velazco, J I; Arthur, P F; Hegarty, R F

    2016-11-01

    The objective of the study was to evaluate associations among animal performance and methane emission traits under feedlot conditions and in respiration chambers in Angus cattle bred to vary in residual feed intake (RFI), which is a measure of feed efficiency. Fifty-nine cattle were tested for feedlot RFI, of which 41 had methane production recorded on an ad libitum grain-based ration in the feedlot, 59 on a restricted grain-based ration in respiration chambers, and 57 on a restricted roughage ration in respiration chambers. The cattle became older and heavier as they went through the different phases of the experiment, but their feed intake (expressed as DMI) and daily emission of enteric methane (methane production rate; MPR) did not increase proportionally, as feed offered was restricted in the respiration chamber tests. Methane emissions by individual animals relative to their DMI were calculated as methane yield (MY; MPR/DMI) and as 2 measures of residual methane production (RMP and RMP), which were calculated as the difference between measured MPR and that predicted from feed intake by 2 different equations. Within each test regime, MPR was positively correlated ( = 0.28 to 0.61) with DMI. Phenotypic correlations for MY, RMP, and RMP between the feedlot test and the restricted grain test ( = 0.40 to 0.43) and between the restricted grain test and the restricted roughage test were moderate ( = 0.36 to 0.41) and moderate to strong between the feedlot test and the restricted roughage test ( = 0.54 to 0.58). These results indicate that the rankings of animals for methane production relative to feed consumed are relatively stable over the 3 test phases. Feedlot feed conversion ratio and RFI were not correlated with MPR in the feedlot test and grain-based chamber test but were negatively correlated with MPR in the chamber roughage test ( = -0.31 and -0.37). Both were negatively correlated with MY and RMP in the feedlot test ( = -0.42 to -0.54) and subsequent chamber roughage test ( = -0.27 to -0.49). Midparent estimated breeding values for RFI tended to be negatively correlated with MY and RMP in the feedlot test ( = -0.27 and -0.27) and were negatively correlated with MY, RMP, and RMP in the chamber roughage test ( = -0.33 to -0.36). These results showed that in young growing cattle, lower RFI was associated with higher MY, RMP, and RMP but had no significant association with MPR.

  2. Evaluation of a Singular Value Decomposition Approach for Impact Dynamic Data Correlation

    NASA Technical Reports Server (NTRS)

    Horta, Lucas G.; Lyle, Karen H.; Lessard, Wendy B.

    2003-01-01

    Impact dynamic tests are used in the automobile and aircraft industries to assess survivability of occupants during crash, to assert adequacy of the design, and to gain federal certification. Although there is no substitute for experimental tests, analytical models are often developed and used to study alternate test conditions, to conduct trade-off studies, and to improve designs. To validate results from analytical predictions, test and analysis results must be compared to determine the model adequacy. The mathematical approach evaluated in this paper decomposes observed time responses into dominant deformation shapes and their corresponding contribution to the measured response. To correlate results, orthogonality of test and analysis shapes is used as a criterion. Data from an impact test of a composite fuselage is used and compared to finite element predictions. In this example, the impact response was decomposed into multiple shapes but only two dominant shapes explained over 85% of the measured response

  3. Performance comparison of new generation HCV core antigen test versus HCV RNA test in management of hepatitis C virus infection.

    PubMed

    Çetiner, Salih; Çetin Duran, Alev; Kibar, Filiz; Yaman, Akgün

    2017-06-01

    The study has evaluated the performance of HCV core antigen (Cag) test by comparing HCV RNA PCR assay which is considered the gold standard for management of HCV infection. Totally, 132 samples sent for HCV RNA (real-time PCR) test were included in the study. Anti-HCV antibody test and HCV Cag test were performed by chemiluminescent enzyme immunoassay (CMEI). Anti-HCV test was positive in all samples. HCV RNA was detected in 112/132 (84.8%) samples, and HCV Cag in 105/132 (79.5%). The most common HCV genotype was genotype 1 (86%). Considering the HCV RNA test as gold standard; the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of Cag test were found to be 93.75%, 100%, 100%, 74.07% and 94.69%, respectively, and paired test results were detected as highly concordant. A high level of correlation was seen between HCV RNA and Cag tests, however, the concordance between the two tests appeared to be disrupted at viral loads lower than 10 3 IU/mL. On the contrary, the correlation reached significance for the values higher than 10 3 IU/mL. Viral loads were in the 17-2500IU/mL range for the negative results for Cag test. Pearson's correlation coefficient revealed a considerably high correlation. The concordance between HCV RNA and Cag tests was disrupted under a viral load lower than 10 3 IU/mL. Therefore, it would be appropriate to consider cost effectiveness, advantages and limitations of the HCV RNA and Cag tests during the decision on which method to use for patient management. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Investigation of difficult component effects on finite element model vibration prediction for the Bell AH-1G helicopter. Volume 1: Ground vibration test results

    NASA Technical Reports Server (NTRS)

    Dompka, R. V.

    1989-01-01

    Under the NASA-sponsored Design Analysis Methods for VIBrationS (DAMVIBS) program, a series of ground vibration tests and NASTRAN finite element model (FEM) correlations were conducted on the Bell AH-1G helicopter gunship to investigate the effects of difficult components on the vibration response of the airframe. Previous correlations of the AH-1G showed good agreement between NASTRAN and tests through 15 to 20 Hz, but poor agreement in the higher frequency range of 20 to 30 Hz. Thus, this effort emphasized the higher frequency airframe vibration response correlations and identified areas that need further R and T work. To conduct the investigations, selected difficult components (main rotor pylon, secondary structure, nonstructural doors/panels, landing gear, engine, fuel, etc.) were systematically removed to quantify their effects on overall vibratory response of the airframe. The entire effort was planned and documented, and the results reviewed by NASA and industry experts in order to ensure scientific control of the testing, analysis, and correlation exercise. In particular, secondary structure and damping had significant effects on the frequency response of the airframe above 15 Hz. Also, the nonlinear effects of thrust stiffening and elastomer mounts were significant on the low frequency pylon modes below main rotor 1p (5.4 Hz). The results of the ground vibration testing are presented.

  5. [Phoneme analysis and phoneme discrimination of juvenile speech therapy school students].

    PubMed

    Franz, S; Rosanowski, F; Eysholdt, U; Hoppe, U

    2011-05-01

    Phoneme analysis and phoneme discrimination, important factors in acquiring spoken and written language, have been evaluated in juvenile speech therapy school students. The results have been correlated with the results of a school achievement test. The following questions were of interest: Do students in the lower verbal skill segment show pathological phoneme analysis and phoneme discrimination skills? Do the results of the school achievement test differ from the results by students visiting German "Hauptschule"? How does phoneme analysis and phoneme discrimination performance correlate to other tested parameters? 74 students of a speech therapy school ranging from 7 (th) to 9 (th) grade were examined (ages 12;10-17;04) with the Heidelberg Phoneme Discrimination Test H-LAD and the school achievement test "Prüfsystem für Schul- und Bildungsberatung PSB-R 6-13". Compared to 4 (th) graders the juvenile speech therapy school students showed worse results in the H-LAD test with good differentiation in the lower measuring range. In the PSB-R 6-13 test the examined students did worse compared to students visiting German "Hauptschule" for all grades except 9 (th) grade. Comparing H-LAD and PSB-R 6-13 shows a significant correlation for the sub-tests covering language competence and intelligence but not for the concentration tests. Pathological phoneme analysis and phoneme discrimination skills suggest elevated need for counseling, but this needs to corroborated through additional linguistic parameters and measuring non-verbal intelligence. Further trails are needed in order to clarify whether the results can lead to sophisticated therapy algorithms for educational purposes. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Clinical applications of correlational vestibular autorotation test.

    PubMed

    Hsieh, Li-Chun; Lin, Te-Ming; Chang, Yu-Min; Kuo, Terry B J; Lee, Gho-She

    2015-06-01

    The correlational vestibular autorotation test (VAT) system has the advantages of good test-retest reliability and calibrations of absolute degrees of eye movement are unnecessary when acquiring a cross correlation coefficient (CCC). The approach is able to efficiently detect peripheral vestibulopathies. A VAT has some drawbacks including poor test-retest reliability and slippage of sensor. This study aimed to develop a correlational VAT system and to evaluate the reliability and applicability of this system. Twenty healthy participants and 10 vertiginous patients were enrolled. Vertical and horizontal autorotations from 0 to 3 Hz with either closed or open eyes were performed. A small sensor and a wireless transmission technique were used to acquire the electro-ocular graph and head velocity signals. The two signals were analyzed using CCCs to assess the functioning of the vestibular ocular reflex (VOR). The results showed a significantly greater CCC for open-eye versus closed-eye of head autorotations. The CCCs also increased significantly with head rotational frequencies. Moreover, the CCCs significantly correlated with the VOR gains at autorotation frequencies ≥1.0 Hz. The test-retest reliability was good (intraclass correlation coefficients ≥0.85). The vertiginous participants had significantly lower individual CCCs and overall average CCC than age- and-gender matched controls.

  7. Orbiter windward surface entry Heating: Post-orbital flight test program update

    NASA Technical Reports Server (NTRS)

    Harthun, M. H.; Blumer, C. B.; Miller, B. A.

    1983-01-01

    Correlations of orbiter windward surface entry heating data from the first five flights are presented with emphasis on boundary layer transition and the effects of catalytic recombination. Results show that a single roughness boundary layer transition correlation developed for spherical element trips works well for the orbiter tile system. Also, an engineering approach for predicting heating in nonequilibrium flow conditions shows good agreement with the flight test data in the time period of significant heating. The results of these correlations, when used to predict orbiter heating for a high cross mission, indicate that the thermal protection system on the windward surface will perform successfully in such a mission.

  8. Investigation of difficult component effects on finite element model vibration prediction for the Bell AG-1G helicopter. Volume 2: Correlation results

    NASA Technical Reports Server (NTRS)

    Dompka, R. V.

    1989-01-01

    Under the NASA-sponsored DAMVIBS (Design Analysis Methods for VIBrationS) program, a series of ground vibration tests and NASTRAN finite element model (FEM) correlations were conducted on the Bell AH-1G helicopter gunship to investigate the effects of difficult components on the vibration response of the airframe. Previous correlations of the AG-1G showed good agreement between NASTRAN and tests through 15 to 20 Hz, but poor agreement in the higher frequency range of 20 to 30 Hz. Thus, this effort emphasized the higher frequency airframe vibration response correlations and identified areas that need further R and T work. To conduct the investigations, selected difficult components (main rotor pylon, secondary structure, nonstructural doors/panels, landing gear, engine, furl, etc.) were systematically removed to quantify their effects on overall vibratory response of the airframe. The entire effort was planned and documented, and the results reviewed by NASA and industry experts in order to ensure scientific control of the testing, analysis, and correlation exercise. In particular, secondary structure and damping had significant effects on the frequency response of the airframe above 15 Hz. Also, the nonlinear effects of thrust stiffening and elastomer mounts were significant on the low frequency pylon modes below main rotor 1p (5.4 Hz). The results of the NASTRAN FEM correlations are given.

  9. Cavitation in liquid cryogens. 4: Combined correlations for venturi, hydrofoil, ogives, and pumps

    NASA Technical Reports Server (NTRS)

    Hord, J.

    1974-01-01

    The results of a series of experimental and analytical cavitation studies are presented. Cross-correlation is performed of the developed cavity data for a venturi, a hydrofoil and three scaled ogives. The new correlating parameter, MTWO, improves data correlation for these stationary bodies and for pumping equipment. Existing techniques for predicting the cavitating performance of pumping machinery were extended to include variations in flow coefficient, cavitation parameter, and equipment geometry. The new predictive formulations hold promise as a design tool and universal method for correlating pumping machinery performance. Application of these predictive formulas requires prescribed cavitation test data or an independent method of estimating the cavitation parameter for each pump. The latter would permit prediction of performance without testing; potential methods for evaluating the cavitation parameter prior to testing are suggested.

  10. Time-lag of the earthquake energy release between three seismic regions

    NASA Astrophysics Data System (ADS)

    Tsapanos, Theodoros M.; Liritzis, Ioannis

    1992-06-01

    Three complete data sets of strong earthquakes ( M≥5.5), which occurred in the seismic regions of Chile, Mexico and Kamchatka during the time period 1899 1985, have been used to test the existence of a time-lag in the seismic energy release between these regions. These data sets were cross-correlated in order to determine whether any pair of the sets are correlated. For this purpose statistical tests, such as the T-test, the Fisher's transformation and probability distribution have been applied to determine the significance of the obtained correlation coefficients. The results show that the time-lag between Chile and Kamchatka is -2, which means that Kamchatka precedes Chile by 2 years, with a correlation coefficient significant at 99.80% level, a weak correlation between Kamchatka-Mexico and noncorrelation for Mexico-Chile.

  11. Sarcoidosis: correlation of pulmonary parenchymal pattern at CT with results of pulmonary function tests

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergin, C.J.; Bell, D.Y.; Coblentz, C.L.

    1989-06-01

    The appearances of the lungs on radiographs and computed tomographic (CT) scans were correlated with degree of uptake on gallium scans and results of pulmonary function tests (PFTs) in 27 patients with sarcoidosis. CT scans were evaluated both qualitatively and quantitatively. Patients were divided into five categories on the basis of the pattern of abnormality at CT: 1 = normal (n = 4); 2 = segmental air-space disease (n = 4); 3 = spherical (alveolar) masslike opacities (n = 4); 4 = multiple, discrete, small nodules (n = 6); and 5 = distortion of parenchymal structures (fibrotic end-stage sarcoidosis) (nmore » = 9). The percentage of the volume judged to be abnormal (CT grade) was correlated with PFT results for each CT and radiographic category. CT grades were also correlated with gallium scanning results and percentage of lymphocytes recovered from bronchoalveolar lavage (BAL). Patients in CT categories 1 and 2 had normal lung function, those in category 3 had mild functional impairment, and those in categories 4 and 5 showed moderate to severe dysfunction. The overall CT grade correlated well with PFT results expressed as a percentage of the predicted value. In five patients, CT scans showed extensive parenchymal disease not seen on radiographs. CT grades did not correlate with the results of gallium scanning or BAL lymphocytes. The authors conclude that patterns of parenchymal sarcoidosis seen at CT correlate with the PFT results and can be used to indicate respiratory impairment.« less

  12. Correlation of Simulation Examination to Written Test Scores for Advanced Cardiac Life Support Testing: Prospective Cohort Study.

    PubMed

    Strom, Suzanne L; Anderson, Craig L; Yang, Luanna; Canales, Cecilia; Amin, Alpesh; Lotfipour, Shahram; McCoy, C Eric; Osborn, Megan Boysen; Langdorf, Mark I

    2015-11-01

    Traditional Advanced Cardiac Life Support (ACLS) courses are evaluated using written multiple-choice tests. High-fidelity simulation is a widely used adjunct to didactic content, and has been used in many specialties as a training resource as well as an evaluative tool. There are no data to our knowledge that compare simulation examination scores with written test scores for ACLS courses. To compare and correlate a novel high-fidelity simulation-based evaluation with traditional written testing for senior medical students in an ACLS course. We performed a prospective cohort study to determine the correlation between simulation-based evaluation and traditional written testing in a medical school simulation center. Students were tested on a standard acute coronary syndrome/ventricular fibrillation cardiac arrest scenario. Our primary outcome measure was correlation of exam results for 19 volunteer fourth-year medical students after a 32-hour ACLS-based Resuscitation Boot Camp course. Our secondary outcome was comparison of simulation-based vs. written outcome scores. The composite average score on the written evaluation was substantially higher (93.6%) than the simulation performance score (81.3%, absolute difference 12.3%, 95% CI [10.6-14.0%], p<0.00005). We found a statistically significant moderate correlation between simulation scenario test performance and traditional written testing (Pearson r=0.48, p=0.04), validating the new evaluation method. Simulation-based ACLS evaluation methods correlate with traditional written testing and demonstrate resuscitation knowledge and skills. Simulation may be a more discriminating and challenging testing method, as students scored higher on written evaluation methods compared to simulation.

  13. An Evaluation of Jet Impingement Heat Transfer Correlations for Piccolo Tube Application

    NASA Technical Reports Server (NTRS)

    Bond, Thomas (Technical Monitor); Wright, William B.

    2004-01-01

    Impinging jets have been used for a wide variety of applications where high rates of heat transfer are desired. This report will present a review of heat transfer correlations that have been published. The correlations were then added to the LEWICE software to evaluate the applicability of these correlations to a piccolo tube anti-icing system. The results of this analysis were then compared quantitatively to test results on a representative piccolo tube system.

  14. Thermosyphon Flooding in Reduced Gravity Environments Test Results

    NASA Technical Reports Server (NTRS)

    Gibson, Marc A.; Jaworske, Donald A.; Sanzi, Jim; Ljubanovic, Damir

    2013-01-01

    The condenser flooding phenomenon associated with gravity aided two-phase thermosyphons was studied using parabolic flights to obtain the desired reduced gravity environment (RGE). The experiment was designed and built to test a total of twelve titanium water thermosyphons in multiple gravity environments with the goal of developing a model that would accurately explain the correlation between gravitational forces and the maximum axial heat transfer limit associated with condenser flooding. Results from laboratory testing and parabolic flights are included in this report as part I of a two part series. The data analysis and correlations are included in a follow on paper.

  15. Oscillating-flow regenerator test rig: Woven screen and metal felt results

    NASA Technical Reports Server (NTRS)

    Gedeon, D.; Wood, J. G.

    1992-01-01

    We present correlating expressions, in terms of Reynolds or Peclet numbers, for friction factors, Nusselt numbers, enhanced axial conduction ratios, and overall heat flux ratios in four porous regenerator samples representative of stirling cycle regenerators: two woven screen samples and two random wire samples. Error estimates and comparison of data with others suggest our correlations are reliable, but we need to test more samples over a range of porosities before our results will become generally useful.

  16. Predicting Middle Level State Standardized Test Results Using Family and Community Demographic Data

    ERIC Educational Resources Information Center

    Tienken, Christopher H.; Colella, Anthony; Angelillo, Christian; Fox, Meredith; McCahill, Kevin R.; Wolfe, Adam

    2017-01-01

    The use of standardized test results to drive school administrator evaluations pervades education policymaking in more than 40 states. However, the results of state standardized tests are strongly influenced by non-school factors. The models of best fit (n = 18) from this correlational, explanatory, longitudinal study predicted accurately the…

  17. Evaluation of the use of pooled serum, pooled muscle tissue fluid (meat juice) and pooled faeces for monitoring pig herds for Salmonella.

    PubMed

    Davies, R H; Heath, P J; Coxon, S M; Sayers, A R

    2003-01-01

    Monitoring for Salmonella in slaughter pigs is important to enable targeted control measures to be applied on problem farms and at the abattoir. The aim of this study was to determine whether pooled serum and meat juice could be used to identify finishing pig herds with a high prevalence of infection. Samples of meat juice, serum, caecal contents, carcase swabs and pooled faeces from pig pens were taken from 20 commercial pig finishing farms and comparisons were made between the results of Salmonella culture, individual ELISA tests on serum and meat juice and pooled samples of serum and meat juice. Salmonella was isolated from samples from 19 of 20 farms. None of the ELISA tests showed a statistically significant correlation with caecal carriage of Salmonella or contamination of carcases. Serum mean optical density (O.D.) from pools of five, 10 or 20 sera showed a significant correlation with the Salmonella status of farm pen faeces. All pooled serum O.D. and sample/positive control ratio results correlated significantly with the results of the conventional individual sample ELISA. There was a statistically significant correlation between the incidence of Salmonella in farm pen pooled faeces and the prevalence of Salmonella in caeca of slaughter pigs. The results show a generally poor correlation between serological and bacteriological results but pooled serum or meat juice samples could be used as a cheaper substitute for serological screening of farms for Salmonella than individual samples. The availability of a cheaper test should allow the costs of Salmonella monitoring of pig farms to be reduced or allow more regular testing to enhance the designation of farm Salmonella risk status.

  18. Short communication: Correlation between within-herd antibody-prevalence and bulk tank milk antibody levels to Mycobacterium avium ssp. paratuberculosis using 2 commercial immunoassays.

    PubMed

    Pesqueira, M N; Yus, E; Factor, C; Mato, I; Sanjuán, M L; Eiras, C; Arnaiz, I; Diéguez, F J

    2017-09-01

    The objective of this study was to determine the correlation between the results obtained with the ELISA technique for antibodies to Mycobacterium avium ssp. paratuberculosis in serum and bulk tank milk at the herd level. For this purpose, 203 samples of bulk tank milk were analyzed with 2 commercial ELISA from dairy herds with a prevalence of seropositive animals that was also determined. In regard to the reference test (results in blood serum), the sensitivity of the bulk tank milk test to detect high-positive herds (≥10% seroprevalence) ranged from 85.7 to 71.4%. The specificity to detect herds with no seropositive animals ranged from 70.5 to 53%. In a quantitative approach, Pearson correlation coefficients, reported as a measure of the linear association between herd seroprevalences and transformed optical density values recorded in bulk tank milk, were 0.39 and 0.54 for the studied ELISA. Although the test results were relatively fairly correlated with the within-herd prevalence, the practical utility of bulk tank milk testing for Mycobacterium avium ssp. paratuberculosis seems limited, especially regarding specificity. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  19. Correlation of MIC value and disk inhibition zone diameters in clinical Legionella pneumophila serogroup 1 isolates.

    PubMed

    Bruin, Jacob P; Diederen, Bram M W; Ijzerman, Ed P F; Den Boer, Jeroen W; Mouton, Johan W

    2013-07-01

    Routine use of disk diffusion tests for detecting antibiotic resistance in Legionella pneumophila has not been described. The goal of this study was to determine the correlation of MIC values and inhibition zone diameter (MDcorr) in clinical L. pneumophila isolates. Inhibition zone diameter of 183 L. pneumophila clinical isolates were determined for ten antimicrobials. Disk diffusion results were correlated with MICs as determined earlier with E-tests. Overall the correlation of MIC values and inhibition zone diameters (MDcorr) of the tested antimicrobials is good, and all antimicrobials showed a WT distribution. Of the tested fluoroquinolones levofloxacin showed the best MDcorr. All macrolides showed a wide MIC distribution and good MDcorr. The MDcorr for cefotaxim, doxycycline and tigecycline was good, while for rifampicin and moxifloxacin, they were not. Overall good correlation between MIC value and disk inhibition zone were found for the fluoroquinolones, macrolides and cefotaxim. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Speech-evoked Brainstem Auditory Responses and Auditory Processing Skills: A Correlation in Adults with Hearing Loss

    PubMed Central

    Sanguebuche, Taissane Rodrigues; Peixe, Bruna Pias; Bruno, Rúbia Soares; Biaggio, Eliara Pinto Vieira; Garcia, Michele Vargas

    2018-01-01

    Introduction  The auditory system consists of sensory structures and central connections. The evaluation of the auditory pathway at a central level can be performed through behavioral and electrophysiological tests, because they are complementary to each other and provide important information about comprehension. Objective  To correlate the findings of speech brainstem-evoked response audiometry with the behavioral tests Random Gap Detection Test and Masking Level Difference in adults with hearing loss. Methods  All patients were submitted to a basic audiological evaluation, to the aforementioned behavioral tests, and to an electrophysiological assessment, by means of click-evoked and speech-evoked brainstem response audiometry. Results  There were no statistically significant values among the electrophysiological test and the behavioral tests. However, there was a significant correlation between the V and A waves, as well as the D and F waves, of the speech-evoked brainstem response audiometry peaks. Such correlations are positive, indicating that the increase of a variable implies an increase in another and vice versa. Conclusion  It was possible to correlate the findings of the speech-evoked brainstem response audiometry with those of the behavioral tests Random Gap Detection and Masking Level Difference. However, there was no statistically significant correlation between them. This shows that the electrophysiological evaluation does not depend uniquely on the behavioral skills of temporal resolution and selective attention. PMID:29379574

  1. Search for Correlated Fluctuations in the Beta+ Decay of Na-22

    NASA Astrophysics Data System (ADS)

    Silverman, M. P.; Strange, W.

    2008-10-01

    Claims for a ``cosmogenic'' force that correlates otherwise independent stochastic events have been made for at least 10 years, based largely on visual inspection of time series of histograms whose shapes were interpreted as suggestive of recurrent patterns with semi-diurnal, diurnal, and monthly periods. Building on our earlier work to test randomness of different nuclear decay processes, we have searched for correlations in the time-series of coincident positron-electron annihilations deriving from beta+ decay of Na-22. Disintegrations were counted within a narrow time window over a period of 7 days, leading to a time series of more than 1 million events. Statistical tests were performed on the raw time series, its correlation function, and its Fourier transform to search for cyclic correlations indicative of quantum-mechanical violating deviations from Poisson statistics. The time series was then partitioned into a sequence of 167 ``bags'' each of 8192 events. A histogram was made of the events of each bag, where contiguous frequency classes differed by a single count. The chronological sequence of histograms was then tested for correlations within classes. In all cases the results of the tests were in accord with statistical control, giving no evidence of correlated fluctuations.

  2. Predicting Performance on State Achievement Tests Using Curriculum-Based Measurement in Reading: A Multilevel Meta-Analysis

    ERIC Educational Resources Information Center

    Yeo, Seungsoo

    2010-01-01

    The purpose of this synthesis was to examine the relationship between Curriculum-Based Measurement (CBM) and statewide achievement tests in reading. A multilevel meta-analysis was used to calculate the correlation coefficient of the population for 27 studies that met the inclusion criteria. Results showed an overall large correlation coefficient…

  3. Agreement and correlation between the straight leg raise and slump tests in subjects with leg pain.

    PubMed

    Walsh, Jeremy; Hall, Toby

    2009-01-01

    The straight leg raise (SLR) and slump tests have traditionally been used to identify nerve root compression arising from disk herniation. However, they may be more appropriate as tests of lumbosacral neural tissue mechanosensitivity. The aim of this study was to determine agreement and correlation between the SLR and slump tests in a population presenting with back and leg pain. This was an observational, cross-sectional study design. Forty-five subjects with unilateral leg pain were recruited from an outpatient Back Pain Screening Clinic at a large teaching hospital in Ireland. The SLR and slump tests were performed on each side. In the event of symptom reproduction, the ankle was dorsiflexed. Reproduction of presenting symptoms, which were intensified by ankle dorsiflexion, was interpreted as a positive test. An inclinometer was used to measure range of motion (ROM). There was substantial agreement between SLR and slump test interpretation (kappa = 0.69) with good correlation in ROM between the 2 tests (r = 0.64) on the symptomatic side. In subjects who had positive results, ROM for both tests was significantly reduced compared to ROM on the contralateral side and ROM in subjects who had negative results. When the SLR and slump tests are interpreted as positive in the event of reproduction of presenting leg pain that are intensified by ankle dorsiflexion, these tests show substantial agreement and good correlation in the leg pain population. When interpreted in this way, these tests may be appropriate tests of neural tissue mechanosensitivity, but further criteria must be met before a definitive conclusion in relation to neural tissue mechanosensitivity may be drawn.

  4. Fluids and Combustion Facility: Fluids Integrated Rack Modal Model Correlation

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Suarez, Vicente J.; Sullivan, Timothy L.; Otten, Kim D.; Akers, James C.

    2005-01-01

    The Fluids Integrated Rack (FIR) is one of two racks in the Fluids and Combustion Facility on the International Space Station. The FIR is dedicated to the scientific investigation of space system fluids management supporting NASA s Exploration of Space Initiative. The FIR hardware was modal tested and FIR finite element model updated to satisfy the International Space Station model correlation criteria. The final cross-orthogonality results between the correlated model and test mode shapes was greater than 90 percent for all primary target modes.

  5. Evaluation of Food Allergy in Children by Skin Prick Tests with Commercial Extracts and Fresh Foods, Specific IgE and, Open Oral Food Challenge-Our Five Years Experience in Food Allergy Work-up.

    PubMed

    Zivanovic, Mirjana; Atanasković-Marković, Marina; Medjo, Biljana; Gavrović-Jankulović, Marija; Smiljanić, Katarina; Tmušić, Vladimir; Djurić, Vojislav

    2017-04-01

    IgE- mediated food allergy affects 6-8% of children. Our study aimed to define the correlations between the results obtained with skin prick tests (SPTs) using commercial extracts and fresh foods, and the correlations between these result and those obtained with specific IgE (sIgE) and/ or challenge. Children aged from 2 months to 6 years were recruited prospectively. Overall 571 children were positive to one food. In all children we performed  SPT using commercial extracts of suspected food and fresh foods and sIgE. If SPT and sIgE test results did not correspond to the history, we performed open oral food challenge. Sensitivity of SPT with commercial extracts for all tested food was poor (3-35%), while  sensitivity of fresh food skin prick tests (FFSPT) was excellent (50-100%), and showed correlation with open oral food challenge (p<0.001). Our results suggest that fresh food extracts are more effective in detecting sensitization and with levels of sIgE greater than class 3 could predict clinical reactivity, without the need for potentially hazardous food challenges.

  6. Comparing Free-Free and Shaker Table Model Correlation Methods Using Jim Beam

    NASA Technical Reports Server (NTRS)

    Ristow, James; Smith, Kenneth Wayne, Jr.; Johnson, Nathaniel; Kinney, Jackson

    2018-01-01

    Finite element model correlation as part of a spacecraft program has always been a challenge. For any NASA mission, the coupled system response of the spacecraft and launch vehicle can be determined analytically through a Coupled Loads Analysis (CLA), as it is not possible to test the spacecraft and launch vehicle coupled system before launch. The value of the CLA is highly dependent on the accuracy of the frequencies and mode shapes extracted from the spacecraft model. NASA standards require the spacecraft model used in the final Verification Loads Cycle to be correlated by either a modal test or by comparison of the model with Frequency Response Functions (FRFs) obtained during the environmental qualification test. Due to budgetary and time constraints, most programs opt to correlate the spacecraft dynamic model during the environmental qualification test, conducted on a large shaker table. For any model correlation effort, the key has always been finding a proper definition of the boundary conditions. This paper is a correlation case study to investigate the difference in responses of a simple structure using a free-free boundary, a fixed boundary on the shaker table, and a base-drive vibration test, all using identical instrumentation. The NAVCON Jim Beam test structure, featured in the IMAC round robin modal test of 2009, was selected as a simple, well recognized and well characterized structure to conduct this investigation. First, a free-free impact modal test of the Jim Beam was done as an experimental control. Second, the Jim Beam was mounted to a large 20,000 lbf shaker, and an impact modal test in this fixed configuration was conducted. Lastly, a vibration test of the Jim Beam was conducted on the shaker table. The free-free impact test, the fixed impact test, and the base-drive test were used to assess the effect of the shaker modes, evaluate the validity of fixed-base modeling assumptions, and compare final model correlation results between these boundary conditions.

  7. Comparison of NASTRAN analysis with ground vibration results of UH-60A NASA/AEFA test configuration

    NASA Technical Reports Server (NTRS)

    Idosor, Florentino; Seible, Frieder

    1990-01-01

    Preceding program flight tests, a ground vibration test and modal test analysis of a UH-60A Black Hawk helicopter was conducted by Sikorsky Aircraft to complement the UH-60A test plan and NASA/ARMY Modern Technology Rotor Airloads Program. The 'NASA/AEFA' shake test configuration was tested for modal frequencies and shapes and compared with its NASTRAN finite element model counterpart to give correlative results. Based upon previous findings, significant differences in modal data existed and were attributed to assumptions regarding the influence of secondary structure contributions in the preliminary NASTRAN modeling. An analysis of an updated finite element model including several secondary structural additions has confirmed that the inclusion of specific secondary components produces a significant effect on modal frequency and free-response shapes and improves correlations at lower frequencies with shake test data.

  8. Timescale Correlation between Marine Atmospheric Exposure and Accelerated Corrosion Testing

    NASA Technical Reports Server (NTRS)

    Montgomery, Eliza L.; Calle, Luz Marina; Curran, Jerone C.; Kolody, Mark R.

    2011-01-01

    Evaluation of metal-based structures has long relied on atmospheric exposure test sites to determine corrosion resistance in marine environments. Traditional accelerated corrosion testing relies on mimicking the exposure conditions, often incorporating salt spray and ultraviolet (UV) radiation, and exposing the metal to continuous or cyclic conditions of the corrosive environment. Their success for correlation to atmospheric exposure is often a concern when determining the timescale to which the accelerated tests can be related. Accelerated laboratory testing, which often focuses on the electrochemical reactions that occur during corrosion conditions, has yet to be universally accepted as a useful tool in predicting the long term service life of a metal despite its ability to rapidly induce corrosion. Although visual and mass loss methods of evaluating corrosion are the standard and their use is imperative, a method that correlates timescales from atmospheric exposure to accelerated testing would be very valuable. This work uses surface chemistry to interpret the chemical changes occurring on low carbon steel during atmospheric and accelerated corrosion conditions with the objective of finding a correlation between its accelerated and long-term corrosion performance. The current results of correlating data from marine atmospheric exposure conditions at the Kennedy Space Center beachside corrosion test site, alternating seawater spray, and immersion in typical electrochemical laboratory conditions, will be presented. Key words: atmospheric exposure, accelerated corrosion testing, alternating seawater spray, marine, correlation, seawater, carbon steel, long-term corrosion performance prediction, X-ray photoelectron spectroscopy.

  9. On the problem of nonsense correlations in allergological tests after routine extraction.

    PubMed

    Rijckaert, G

    1981-01-01

    The influence of extraction procedures and culturing methods of material used for the preparation of allergenic extracts on correlation patterns found in allergological testing (skin test and RAST) was investigated. In our laboratory a short extraction procedure performed at O degrees C was used for Aspergillus repens. A. penicilloides, Wallemia sebi, their rearing media and non-inoculated medium. For the commercially available extracts from house dust, house-dust mite, pollen of Dactylus glomerata and A. penicilloides a longer procedure (several days) performed at room temperature was used. Statistical analysis showed a separation of all test results into two clusters, each cluster being composed of correlations between extracts from only one the manufacturers did not show any correlation. The correlations found between the short time incubated extracts of the xerophilic fungi and their rearing media could be explained by genetical and biochemical relationships between these fungi depending on ecological conditions. However, while the correlation found between house dust and house-dust mite is understandable, correlations found between long time incubated extracts from house-dust mite and D. glomerata or A. penicilloides may be nonsense correlations, that do not adequately describe the in vivo situation. The similarity of these extracts is presumably artificially created during extraction.

  10. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment.

    PubMed

    Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong

    2014-12-08

    In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  11. Coexpression of aPKCλ/ι and IL-6 in prostate cancer tissue correlates with biochemical recurrence.

    PubMed

    Ishiguro, Hitoshi; Akimoto, Kazunori; Nagashima, Yoji; Kagawa, Eriko; Sasaki, Takeshi; Sano, Jin-yu; Takagawa, Ryo; Fujinami, Kiyoshi; Sasaki, Kazunori; Aoki, Ichiro; Ohno, Shigeo; Kubota, Yoshinobu; Uemura, Hiroji

    2011-08-01

    Atypical protein kinase C λ/ι (aPKCλ/ι) and interleukin-6 (IL-6) have been implicated in prostate cancer progression, the mechanisms of which have been demonstrated both in vitro and in vivo. However, the clinical significance of the correlation between the expressions of these factors remains to be clarified. In the present study, we report a significant correlation between aPKCλ/ι and IL-6 proteins in prostate cancer tissue by immunohistochemical staining. We evaluated the association of both proteins by analyzing clinicopathological parameters using chi-square test, Kaplan-Meier with log-rank test, and a Cox proportional hazard regression model in univariate and multivariate analyses. The results again showed that the expression of aPKCλ/ι and IL-6 correlates in prostate cancer tissue (P < 0.001). Atypical protein kinase C λ/ι was also found to correlate with the Gleason score (P < 0.001) and with biochemical recurrence after prostatectomy (P = 0.02). Furthermore, aPKCλ/ι correlated with biochemical recurrence in a Kaplan-Meier and log-rank test (P = 0.01) and Cox analysis (P = 0.02 in the univariate analysis, P = 0.02 in the multivariate analysis). The coexpression of aPKCλ/ι and IL-6 also correlated with biochemical recurrence by Kaplan-Meier and log-rank test (P = 0.005) and Cox analysis (P = 0.01 in the univariate analysis, P = 0.03 in the multivariate analysis). These results indicate a strong correlation between aPKCλ/ι and IL-6 in prostate tumors, and that the aPKCλ/ι-IL-6 axis is a reliable prognostic factor for the biochemical recurrence of this cancer. © 2011 Japanese Cancer Association.

  12. Roles of Engineering Correlations in Hypersonic Entry Boundary Layer Transition Prediction

    NASA Technical Reports Server (NTRS)

    Campbell, Charles H.; Anderson, Brian P.; King, Rudolph A.; Kegerise, Michael A.; Berry, Scott A.; Horvath, Thomas J.

    2010-01-01

    Efforts to design and operate hypersonic entry vehicles are constrained by many considerations that involve all aspects of an entry vehicle system. One of the more significant physical phenomenon that affect entry trajectory and thermal protection system design is the occurrence of boundary layer transition from a laminar to turbulent state. During the Space Shuttle Return To Flight activity following the loss of Columbia and her crew of seven, NASA's entry aerothermodynamics community implemented an engineering correlation based framework for the prediction of boundary layer transition on the Orbiter. The methodology for this implementation relies upon similar correlation techniques that have been is use for several decades. What makes the Orbiter boundary layer transition correlation implementation unique is that a statistically significant data set was acquired in multiple ground test facilities, flight data exists to assist in establishing a better correlation and the framework was founded upon state of the art chemical nonequilibrium Navier Stokes flow field simulations. Recent entry flight testing performed with the Orbiter Discovery now provides a means to validate this engineering correlation approach to higher confidence. These results only serve to reinforce the essential role that engineering correlations currently exercise in the design and operation of entry vehicles. The framework of information related to the Orbiter empirical boundary layer transition prediction capability will be utilized to establish a fresh perspective on this role, and to discuss the characteristics which are desirable in a next generation advancement. The details of the paper will review the experimental facilities and techniques that were utilized to perform the implementation of the Orbiter RTF BLT Vsn 2 prediction capability. Statistically significant results for multiple engineering correlations from a ground testing campaign will be reviewed in order to describe why only certain correlations were selected for complete implementation to support the Shuttle Program. Historical Orbiter flight data on early boundary layer transition due to protruding gap fillers will be described in relation to the selected empirical correlations. In addition, Orbiter entry flight testing results from the BLT Flight Experiment will be discussed in relation to these correlations. Applicability of such correlations to the entry design problem will be reviewed, and finally a perspective on the desirable characteristics for a next generation capability based on high fidelity physical models will be provided.

  13. FUNCTIONAL PERFORMANCE AND KNEE LAXITY IN NORMAL INDIVIDUALS AND IN INDIVIDUALS SUBMITTED TO ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION

    PubMed Central

    de Vasconcelos, Rodrigo Antunes; Bevilaqua-Grossi, Débora; Shimano, Antonio Carlos; Jansen Paccola, Cleber Antonio; Salvini, Tânia Fátima; Prado, Christiane Lanatovits; Mello Junior, Wilson A.

    2015-01-01

    The aim of this study was to analyze the correlation between deficits in the isokinetic peak torque of the knee extensors and flexors with hop tests, postoperative knee laxity and functional scores in normal and ACL- reconstructed subjects with patellar tendon and hamstring tendon autografts. Methods: Sixty male subjects were enrolled and subdivided into three groups: Twenty subjects without knee injuries (GC group) and two groups of 20 subjects submitted to ACL reconstruction with patellar tendon (GTP group) and hamstrings autograft (GTF group). Results: The results showed significant correlation between knee extensors peak torque and performance in the hop tests for GTF and GC groups. There are no significantly correlations between post op knee laxity and Lysholm score compared with the hop tests and peak torque deficits. Concerning the differences between groups, the GTP group showed greater peak torque deficits in knee extensors, worst Lysholm scores and higher percentage of individuals with lower limb symmetry index (ISM) < 90% in both hop tests when compared to the other two groups. Conclusion: It is not recommendable to use only one measurement instrument for the functional evaluation of ACL-reconstructed patients, because significant correlation between peak torque, subject's functional score, knee laxity and hop tests were not observed in all groups. PMID:26998464

  14. Clinical usefulness of the pendulum test using a NK table to measure the spasticity of patients with brain lesions.

    PubMed

    Kim, Yong-Wook

    2013-10-01

    . [Purpose] The purpose of the present study was to investigate the clinical usefulness (reliability and validity) of the pendulum test using a Noland-Kuckhoff (NK) table with an attached electrogoniometer to measure the spasticity of patients with brain lesions. [Subjects] The subjects were 31 patients with stroke or traumatic brain injury. [Methods] The intraclass correlation coefficient (ICC) was used to verify the test-retest reliability of spasticity measures obtained using the pendulum test. Pearson's product correlation coefficient was used to examine the validity of the pendulum test using the amplitude of the patellar tendon reflex (PTR) test, an objective and quantitative measure of spasticity. [Results] The test-retest reliability was high, reflecting a significant correlation between the test and the retest (ICCs = 0.95-0.97). A significant negative correlation was found between the amplitude of the PTR test and the four variables measured in the pendulum test (r = -0.77- -0.85). [Conclusion] The pendulum test using a NK table is an objective measure of spasticity and can be used in the clinical setting in place of more expensive and complicated equipment. Further studies are needed to investigate the therapeutic effect of this method on spasticity.

  15. Assessing Computer Literacy: A Validated Instrument and Empirical Results.

    ERIC Educational Resources Information Center

    Gabriel, Roy M.

    1985-01-01

    Describes development of a comprehensive computer literacy assessment battery for K-12 curriculum based on objectives of a curriculum implemented in the Worldwide Department of Defense Dependents Schools system. Test development and field test data are discussed and a correlational analysis which assists in interpretation of test results is…

  16. High School Competency Tests and ESL Students: Some Limited Data, Some Larger Questions and a Few Suggestions.

    ERIC Educational Resources Information Center

    McGroarty, Mary

    Graduation competency test results of 27 Spanish-speaking high school students in grades 10-12 indicate that overall oral English proficiency is moderately to strongly correlated with test passage in all three areas tested: mathematics, reading, and writing. These results agree with previous research. However, despite the intuitive appeal of…

  17. Reliability and validity of a self-administered tool for online neuropsychological testing: The Amsterdam Cognition Scan.

    PubMed

    Feenstra, Heleen E M; Murre, Jaap M J; Vermeulen, Ivar E; Kieffer, Jacobien M; Schagen, Sanne B

    2018-04-01

    To facilitate large-scale assessment of a variety of cognitive abilities in clinical studies, we developed a self-administered online neuropsychological test battery: the Amsterdam Cognition Scan (ACS). The current studies evaluate in a group of adult cancer patients: test-retest reliability of the ACS and the influence of test setting (home or hospital), and the relationship between our online and a traditional test battery (concurrent validity). Test-retest reliability was studied in 96 cancer patients (57 female; M age  = 51.8 years) who completed the ACS twice. Intraclass correlation coefficients (ICCs) were used to assess consistency over time. The test setting was counterbalanced between home and hospital; influence on test performance was assessed by repeated measures analyses of variance. Concurrent validity was studied in 201 cancer patients (112 female; M age  = 53.5 years) who completed both the online and an equivalent traditional neuropsychological test battery. Spearman or Pearson correlations were used to assess consistency between online and traditional tests. ICCs of the online tests ranged from .29 to .76, with an ICC of .78 for the ACS total score. These correlations are generally comparable with the test-retest correlations of the traditional tests as reported in the literature. Correlating online and traditional test scores, we observed medium to large concurrent validity (r/ρ = .42 to .70; total score r = .78), except for a visuospatial memory test (ρ = .36). Correlations were affected-as expected-by design differences between online tests and their offline counterparts. Although development and optimization of the ACS is an ongoing process, and reliability can be optimized for several tests, our results indicate that it is a highly usable tool to obtain (online) measures of various cognitive abilities. The ACS is expected to facilitate efficient gathering of data on cognitive functioning in the near future.

  18. Correlation of the Y-Balance Test with Lower-limb Strength of Adult Women

    PubMed Central

    Lee, Dong-Kyu; Kim, Gyoung-Mo; Ha, Sung-Min; Oh, Jae-Seop

    2014-01-01

    [Purpose] The purpose of this study was to elucidate the relationship between Y-balance test (YBT) distance and the lower-limb strength of adult women. [Subjects] Forty women aged 45 to 80 years volunteered for this study. [Methods] The participants were tested for maximal muscle strength of the lower limbs (hip extensors, hip flexors, hip abductors, knee extensors, knee flexors, and ankle dorsiflexors) and YBT distances in the anterior, posteromedial, and posterolateral directions. Pearson’s correlation coefficient was used to quantify the linear relationships between YBT distances and lower-limb strength. [Results] Hip extensor and knee flexor strength were positively correlated with YBT anterior distance. Hip extensor, hip abductor, and knee flexor strength were positively correlated with the YBT posteromedial distance. Hip extensor and knee flexor strength were positively correlated with YBT posterolateral distance. [Conclusion] There was a weak correlation between lower-limb strength (hip extensors, hip abductors, and knee flexors) and dynamic postural control as measured by the YBT. PMID:24926122

  19. Comparison of indoor-outdoor thermal performance for the Sunpak evacuated tube liquid collector

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Performance data for current Sunpak production collectors is presented. The effects of an improved manifold are seen from the test results. The test results show excellent correlation between the solar simulator derived test results and outdoor test results. Also, because of different incident angle modifiers, the all-day efficiency of this collector with a diffuse reflector is comparable to the performance with the standard shaped specular reflector.

  20. Speed and agility of 12- and 14-year-old elite male basketball players.

    PubMed

    Jakovljevic, Sasa T; Karalejic, Milivoje S; Pajic, Zoran B; Macura, Marija M; Erculj, Frane F

    2012-09-01

    The aims of this study were (a) to identify and compare the speed and agility of 12- and 14-year-old elite male basketball players and (b) to investigate relations between speed and agility for both age groups of basketball players, to help coaches to improve their work. Sixty-four players aged 12 (M = 11.98 years, SD = 0.311) and 54 players aged 14 (M = 14.092 years, SD = 0.275) were tested. Three agility tests: agility t-test, zigzag agility drill, and agility run 4 × 15 m and 3 speed tests: 20-m run, 30-m run, and 50-m run were applied. Fourteen-year-old players achieved significantly better results in all speed and agility tests compared with 12-year-old players. The correlation coefficient (r = 0.81, p = 0.001) showed that 12-year-old players have the same ability in the 30- and 50-m runs. The other correlation coefficient (r = 0.59, p = 0.001) indicated that 20- and 30-m runs had inherently different qualities. The correlation coefficients between agility tests were <0.71, and therefore, each test in this group represents a specific task. In 14-year-old players, the correlation coefficients between the speed test results were <0.71. In contrast, the correlation coefficients between the agility tests were >0.71, which means that all the 3 tests represent the same quality. During the speed training of 12-year-old players, it is advisable to focus on shorter running distances, up to 30 m. During the agility training of the same players, it is useful to apply exercises with various complexities. In speed training of the 14-year-old players, the 30- and 50-m runs should be applied, and agility training should include more specific basketball movements and activities.

  1. Effectiveness of Sealed Double-Ring Infiltrometers{trademark} and effects of changes in atmospheric pressure on hydraulic conductivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McMullin, S.R.

    The Savannah River Site is currently evaluating some 40 hazardous and radioactive-waste sites for remediation. Among the remedial alternatives considered is closure using a kaolin clay cap. The hydraulic conductivity suggested by the US Environmental Protection Agency is 1.0 {times} 10{sup {minus}7} cm/sec. One instrument to measure this value is the Sealed Double-Ring Infiltrometer{trademark} (SDRI). Six SDRI were recently installed on a kaolin test cap. Test results demonstrated uniform performance of these instruments. However, the test data showed as much as an order of magnitude of variation over time. This variation is attributed to both internal structural heterogeneity and variablemore » external boundary conditions. The internal heterogeneity is caused by construction variability within a specified range of moisture and density. The external influences considered are temperature and barometric pressure. Temperature was discharged as a source of heterogeneity because of a lack of correlation with test data and a negligible impact from the range of variability. However, a direct correlation was found between changes in barometric pressure and hydraulic conductivity. This correlation is most pronounced when pressure changes occur over a short period of time. Additionally, this correlation is related to a single soil layer. When the wetting front passes into a more porous foundation layer, the correlation with pressure changes disappears. Conclusions are that the SDRI performs adequately, with good repeatability of results. The duration of test is critical to assure a statistically valid data set. Data spikes resulting from pressure changes should be identified, and professional judgment used to determine the representative hydraulic conductivity. Further evaluation is recommended to determine the impact of pressure change on the actual hydraulic conductivity.« less

  2. Tests of blending and correlation of distillate fuel properties

    NASA Technical Reports Server (NTRS)

    Erwin, J.; Bowden, J. N.

    1982-01-01

    The development of a fuel test matrix, results from tests of several blends of distillate aircraft fuels, and the use of correlations in formulation determination during a NASA-sponsored program to identify new aircraft fuels are described. The program was initiated in order to characterize fuel blends which are appropriate for different types of combustors in use and under development. The fuels were required to feature a specified range of properties. Attention is given to fuel volatility, hydrogen content, aromatic content, freezing point, kinematic viscosity, and naphthalene content. Paraffinic and naphtenic base stocks were employed, using alkyl benzene, naphthene benzenes, and naphthalenes to adjust the blend properties. Categories for the test fuels comprised source-controlled and composition controlled fuels. Test results and compositions of various fuels are provided.

  3. The reliability and validity of the SF-8 with a conflict-affected population in northern Uganda

    PubMed Central

    Roberts, Bayard; Browne, John; Ocaka, Kaducu Felix; Oyok, Thomas; Sondorp, Egbert

    2008-01-01

    Background The SF-8 is a health-related quality of life instrument that could provide a useful means of assessing general physical and mental health amongst populations affected by conflict. The purpose of this study was to test the validity and reliability of the SF-8 with a conflict-affected population in northern Uganda. Methods A cross-sectional multi-staged, random cluster survey was conducted with 1206 adults in camps for internally displaced persons in Gulu and Amuru districts of northern Uganda. Data quality was assessed by analysing the number of incomplete responses to SF-8 items. Response distribution was analysed using aggregate endorsement frequency. Test-retest reliability was assessed in a separate smaller survey using the intraclass correlation test. Construct validity was measured using principal component analysis, and the Pearson Correlation test for item-summary score correlation and inter-instrument correlations. Known groups validity was assessed using a two sample t-test to evaluates the ability of the SF-8 to discriminate between groups known to have, and not have, physical and mental health problems. Results The SF-8 showed excellent data quality. It showed acceptable item response distribution based upon analysis of aggregate endorsement frequencies. Test-retest showed a good intraclass correlation of 0.61 for PCS and 0.68 for MCS. The principal component analysis indicated strong construct validity and concurred with the results of the validity tests by the SF-8 developers. The SF-8 also showed strong construct validity between the 8 items and PCS and MCS summary score, moderate inter-instrument validity, and strong known groups validity. Conclusion This study provides evidence on the reliability and validity of the SF-8 amongst IDPs in northern Uganda. PMID:19055716

  4. An Ecological Study of Anterior Cruciate Ligament Reconstruction, Part 2: Functional Performance Tests Correlate With Return-to-Sport Outcomes.

    PubMed

    McGrath, Timothy M; Waddington, Gordon; Scarvell, Jennie M; Ball, Nick; Creer, Rob; Woods, Kevin; Smith, Damian; Adams, Roger

    2017-02-01

    Additional high-quality prospective studies are needed to better define the objective criteria used in relation to return-to-sport decisions after anterior cruciate ligament (ACL) reconstruction in active populations. To investigate prospectively the relationship between functional performance test results at 24 weeks postoperative and return-to-sport activity (Tegner activity score) at 12 and 24 months, respectively, after synthetic (ligament advanced reinforcement system [LARS]) and autograft (doubled semitendinosus/gracilis [2ST/2GR]) ACL reconstructions. Case series; Level of evidence, 4. A total of 64 patients who underwent ACL reconstruction (32 LARS, 32 2ST/2GR autograft; mean age, 27.9 years; body mass index [BMI], 24.9 kg/m 2 ) were assessed preoperatively and at staged intervals postoperatively up to 24 weeks for isokinetic testing of quadriceps and hamstring average power per repetition at 60 deg/s and 180 deg/s, a battery of hop tests, peak vertical ground-reaction force (vGRF), and time to peak vGRF (in seconds) during a step- and jump-down task onto a force platform and peak speed (m/s) using a global positioning system (GPS unit) during a running task. A cohort of 32 healthy matched participants (mean age, 26.31 years; BMI, 25.7 kg/m 2 ) were also tested to act as reference. Pearson correlation was calculated to assess correlation of each performance measure at 24 weeks postoperative with activity outcomes (Tegner score) at 12 and 24 months. The strongest correlation between physical performance tests and return-to-sport outcomes was observed with peak speed during running. Large correlations were also observed for hamstring isokinetic power and hop test for distance. Moderate correlations were observed for timed hop, peak vGRF during a jump-down task, and quadriceps isokinetic power. No statistical correlations were observed for time to peak vGRF during a step-down and jump-down task as well as peak vGRF during a step-down task. When the performance tests were pooled together, mean postoperative improvements of 24% were observed from preoperative to 24 weeks within the surgical cohort. For each performance test, preoperative level of function strongly correlated with performance levels on the same test at 24 weeks. The results of this study indicate that clinicians might seek to prioritize these tests and the rehabilitation themes they imply when seeking to maximize postoperative ACL activity outcomes. The observed strength between pre- and postoperative performance tests and return-to-sport outcomes within this study highlights the potential value of preoperative conditioning before undergoing ACL reconstruction. Future research should examine absolute predictive criterion thresholds for functional performance-based tests and reinjury risk reduction after ACL reconstruction.

  5. Meta-analysis of correlations revisited: attempted replication and extension of Field's (2001) simulation studies.

    PubMed

    Hafdahl, Adam R; Williams, Michelle A

    2009-03-01

    In 2 Monte Carlo studies of fixed- and random-effects meta-analysis for correlations, A. P. Field (2001) ostensibly evaluated Hedges-Olkin-Vevea Fisher-z and Schmidt-Hunter Pearson-r estimators and tests in 120 conditions. Some authors have cited those results as evidence not to meta-analyze Fisher-z correlations, especially with heterogeneous correlation parameters. The present attempt to replicate Field's simulations included comparisons with analytic values as well as results for efficiency and confidence-interval coverage. Field's results under homogeneity were mostly replicable, but those under heterogeneity were not: The latter exhibited up to over .17 more bias than ours and, for tests of the mean correlation and homogeneity, respectively, nonnull rejection rates up to .60 lower and .65 higher. Changes to Field's observations and conclusions are recommended, and practical guidance is offered regarding simulation evidence and choices among methods. Most cautions about poor performance of Fisher-z methods are largely unfounded, especially with a more appropriate z-to-r transformation. The Appendix gives a computer program for obtaining Pearson-r moments from a normal Fisher-z distribution, which is used to demonstrate distortion due to direct z-to-r transformation of a mean Fisher-z correlation.

  6. Correlation between Colon Transit Time Test Value and Initial Maintenance Dose of Laxative in Children with Chronic Functional Constipation

    PubMed Central

    Kim, Mock Ryeon; Park, Hye Won; Son, Jae Sung; Lee, Ran

    2016-01-01

    Purpose To evaluate the correlation between colon transit time (CTT) test value and initial maintenance dose of polyethylene glycol (PEG) 4000 or lactulose. Methods Of 415 children with chronic functional constipation, 190 were enrolled based on exclusion criteria using the CTT test, defecation diary, and clinical chart. The CTT test was performed with prior disimpaction. The laxative dose for maintenance was determined on the basis of the defecation diary and clinical chart. The Shapiro-Wilk test and Pearson's and Spearman's correlations were used for statistical analysis. Results The overall group median value and interquartile range of the CTT test was 43.8 (31.8) hours. The average PEG 4000 dose for maintenance in the overall group was 0.68±0.18 g/kg/d; according to age, the dose was 0.73±0.16 g/kg/d (<8 years), 0.53±0.12 g/kg/d (8 to <12 years), and 0.36±0.05 g/kg/d (12 to 15 years). The dose of lactulose was 1.99±0.43 mL/kg/d (<8 years) or 1.26±0.25 mL/kg/d (8 to <12 years). There was no significant correlation between CTT test value and initial dose of laxative, irrespective of the subgroup (encopresis, abnormal CTT test subtype) for either laxative. Even in the largest group (overall, n=109, younger than 8 years and on PEG 4000), the correlation was weak (Pearson's correlation coefficient [R]=0.268, p=0.005). Within the abnormal transit group, subgroup (n=73, younger than 8 years and on PEG 4000) correlation was weak (R=0.267, p=0.022). Conclusion CTT test value cannot predict the initial maintenance dose of PEG 4000 or lactulose with linear correlation. PMID:27738600

  7. Application of subsize specimens in nuclear plant life extension

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosinski, S.T.; Kumar, A.S.; Cannon, S.C.

    1991-01-01

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missour-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full size samples. The program involves the impact testing of unirradiated and irradiated full, half, and third size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials unirradiated and irradiated full, half, and third size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) willmore » be tested. This paper will provide details of the program and present results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full, half, and third size A533 Grade B Charpy V-notch specimens.« less

  8. Application of subsize specimens in nuclear plant life extension

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosinski, S.T.; Kumar, A.S.; Cannon, S.C.

    1991-12-31

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missour-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full size samples. The program involves the impact testing of unirradiated and irradiated full, half, and third size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials unirradiated and irradiated full, half, and third size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) willmore » be tested. This paper will provide details of the program and present results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full, half, and third size A533 Grade B Charpy V-notch specimens.« less

  9. Spatial Autocorrelation Approaches to Testing Residuals from Least Squares Regression.

    PubMed

    Chen, Yanguang

    2016-01-01

    In geo-statistics, the Durbin-Watson test is frequently employed to detect the presence of residual serial correlation from least squares regression analyses. However, the Durbin-Watson statistic is only suitable for ordered time or spatial series. If the variables comprise cross-sectional data coming from spatial random sampling, the test will be ineffectual because the value of Durbin-Watson's statistic depends on the sequence of data points. This paper develops two new statistics for testing serial correlation of residuals from least squares regression based on spatial samples. By analogy with the new form of Moran's index, an autocorrelation coefficient is defined with a standardized residual vector and a normalized spatial weight matrix. Then by analogy with the Durbin-Watson statistic, two types of new serial correlation indices are constructed. As a case study, the two newly presented statistics are applied to a spatial sample of 29 China's regions. These results show that the new spatial autocorrelation models can be used to test the serial correlation of residuals from regression analysis. In practice, the new statistics can make up for the deficiencies of the Durbin-Watson test.

  10. Accuracy of a new partial coherence interferometry analyser for biometric measurements.

    PubMed

    Holzer, M P; Mamusa, M; Auffarth, G U

    2009-06-01

    Precise biometry is an essential preoperative measurement for refractive surgery as well as cataract surgery. A new device based on partial coherence interferometry technology was tested and evaluated for accuracy of measurements. In a prospective study 200 eyes of 100 healthy phakic volunteers were examined with a functional prototype of the new ALLEGRO BioGraph (Wavelight AG)/LENSTAR LS 900 (Haag Streit AG) biometer and with the IOLMaster V.5 (Carl Zeiss Meditec AG). As recommended by the manufacturers, repeated measurements were performed with both devices and the results compared using Spearman correlation calculations (WinSTAT). Spearman correlation showed high correlations for axial length and keratometry measurements between the two devices tested. Anterior chamber depth, however, had a lower correlation between the two biometry devices. In addition, the mean values of the anterior chamber depth differed (IOLMaster 3.48 (SD 0.42) mm versus BioGraph/LENSTAR 3.64 (SD 0.26) mm); however, this difference was not statistically different (p>0.05, t test). The new biometer provided results that correlated very well with those of the IOLMaster. The ALLEGRO BioGraph/LENSTAR LS 900 is a precise device containing additional features that will be helpful tools for any cataract or refractive surgeon.

  11. Correlation between mobility assessed by the Modified Rivermead Mobility Index and physical function in stroke patients

    PubMed Central

    Park, Gi-Tae; Kim, Mihyun

    2016-01-01

    [Purpose] The purpose of this study was to investigate the relationship between mobility assessed by the Modified Rivermead Mobility Index and variables associated with physical function in stroke patients. [Subjects and Methods] One hundred stroke patients (35 males and 65 females; age 58.60 ± 13.91 years) participated in this study. Modified Rivermead Mobility Index, muscle strength (manual muscle test), muscle tone (Modified Ashworth Scale), range of motion of lower extremity, sensory function (light touch and proprioception tests), and coordination (heel to shin and lower-extremity motor coordination tests) were assessed. [Results] The Modified Rivermead Mobility Index was correlated with all the physical function variables assessed, except the degree of knee extension. In addition, stepwise linear regression analysis revealed that coordination (heel to shin test) was the explanatory variable closely associated with mobility in stroke patients. [Conclusion] The Modified Rivermead Mobility Index score was significantly correlated with all the physical function variables. Coordination (heel to shin test) was closely related to mobility function. These results may be useful in developing rehabilitation programs for stroke patients. PMID:27630440

  12. Understanding GRETINA using angular correlation method

    NASA Astrophysics Data System (ADS)

    Austin, Madeline

    2015-10-01

    The ability to trace the path of gamma rays through germanium is not only necessary for taking full advantage of GRETINA but also a promising possibility for homeland security defense against nuclear threats. This research tested the current tracking algorithm using the angular correlation method by comparing results from raw and tracked data to the theoretical model for Co-60. It was found that the current tracking method is unsuccessful in reproducing angular correlation. Variations to the tracking algorithm were made in the FM value, tracking angle, number of angles of separation observed, and window of coincidence in attempt to improve correlation results. From these variations it was observed that having a larger FM improved results, reducing the number of observational angles worsened correlation, and that overall larger tracking angles improved with larger windows of coincidence and vice-verse. Future research would be to refine the angle of measurement for raw data and to explore the possibility of an energy dependence by testing other elements. This work is supported by the United States Department of Energy, Office of Science, under Contract Number DE-AC02-06CH11357

  13. Electrocardiogram interpretation skills among ambulance nurses.

    PubMed

    Werner, Kristoffer; Kander, Kristofer; Axelsson, Christer

    2016-06-01

    To describe ambulance nurses' practical electrocardiogram (ECG) interpretation skills and to measure the correlation between these skills and factors that may impact on the level of knowledge. This study was conducted using a prospective quantitative survey with questionnaires and a knowledge test. A convenience sample collection was conducted among ambulance nurses in three different districts in western Sweden. The knowledge test consisted of nine different ECGs. The score of the ECG test were correlated against the questions in the questionnaire regarding both general ECG interpretation skill and ability to identify acute myocardial infarction using Mann-Whitney U test, Kruskal-Wallis test and Spearman's rank correlation. On average, the respondents had 54% correct answers on the test and identified 46% of the ECGs indicating acute myocardial infarction. The median total score was 9 of 16 (interquartile range 7-11) and 1 of 3 (IQR 1-2) in infarction points. No correlation between ECG interpretation skill and factors such as education and professional experience was found, except that coronary care unit experience was associated with better results on the ECG test. Ambulance nurses have deficiencies in their ECG interpretation skills. This also applies to conditions where the ambulance crew has great potential to improve the outcome of the patient's health, such as myocardial infarction and cardiac arrest. Neither education, extensive experience in ambulance service nor in nursing contributed to an improved result. The only factor of importance for higher ECG interpretation knowledge was prior experience of working in a coronary care unit. © The European Society of Cardiology 2014.

  14. Biologic variability and correlation of platelet function testing in healthy dogs.

    PubMed

    Blois, Shauna L; Lang, Sean T; Wood, R Darren; Monteith, Gabrielle

    2015-12-01

    Platelet function tests are influenced by biologic variability, including inter-individual (CVG ) and intra-individual (CVI ), as well as analytic (CVA ) variability. Variability in canine platelet function testing is unknown, but if excessive, would make it difficult to interpret serial results. Additionally, the correlation between platelet function tests is poor in people, but not well described in dogs. The aims were to: (1) identify the effect of variation in preanalytic factors (venipuncture, elapsed time until analysis) on platelet function tests; (2) calculate analytic and biologic variability of adenosine diphosphate (ADP) and arachidonic acid (AA)-induced thromboelastograph platelet mapping (TEG-PM), ADP-, AA-, and collagen-induced whole blood platelet aggregometry (WBA), and collagen/ADP and collagen/epinephrine platelet function analysis (PFA-CADP, PFA-CEPI); and (3) determine the correlation between these variables. In this prospective observational trial, platelet function was measured once every 7 days, for 4 consecutive weeks, in 9 healthy dogs. In addition, CBC, TEG-PM, WBA, and PFA were performed. Overall coefficients of variability ranged from 13.3% to 87.8% for the platelet function tests. Biologic variability was highest for AA-induced maximum amplitude generated during TEG-PM (MAAA; CVG = 95.3%, CVI = 60.8%). Use of population-based reference intervals (RI) was determined appropriate only for PFA-CADP (index of individuality = 10.7). There was poor correlation between most platelet function tests. Use of population-based RI appears inappropriate for most platelet function tests, and tests poorly correlate with one another. Future studies on biologic variability and correlation of platelet function tests should be performed in dogs with platelet dysfunction and those treated with antiplatelet therapy. © 2015 American Society for Veterinary Clinical Pathology.

  15. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study

    PubMed Central

    Hashmi, Ali M.; Naz, Shahana; Asif, Aftab; Khawaja, Imran S.

    2016-01-01

    Objective: To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. Methods: After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. Results: The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. Conclusion: The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research. PMID:28083049

  16. Estimating correlation of prevalence at two locations in the farm-to-table continuum using qualitative test data.

    PubMed

    Williams, Michael S; Ebel, Eric D

    2017-03-20

    The presence or absence of contaminants in food samples changes as a commodity moves along the farm-to-table continuum. Interest lies in the degree to which the prevalence (i.e., infected animals or contaminated sample units) at one location in the continuum, as measured by the proportion of test-positive samples, is correlated with the prevalence at a location later in the continuum. If prevalence of a contaminant at one location in the continuum is strongly correlated with the prevalence of the contaminant later in the continuum, then the effect of changes in contamination on overall food safety can be better understood. Pearson's correlation coefficient is one of the simplest metrics of association between two measurements of prevalence but it is biased when data consisting of presence/absence testing results are used to directly estimate the correlation. This study demonstrates the potential magnitude of this bias and explores the utility of three methods for unbiased estimation of the degree of correlation in prevalence. An example, based on testing broiler chicken carcasses for Salmonella at re-hang and post-chill, is used to demonstrate the methods. Published by Elsevier B.V.

  17. The correlation between intradermal testing and serum specific IgE to house dust mite in negative skin prick test allergic rhinitis adult patients.

    PubMed

    Tantilipikorn, Pongsakorn; Danpornprasert, Piyanart; Ngaotepprutaram, Premyot; Assanasen, Paraya; Bunnag, Chaweewan; Thinkhamrop, Bandit

    2015-12-01

    Diagnosis of allergic rhinitis (AR) is based on history, physical examination, and skin prick test (SPT) while intradermal (ID) test can be performed to confirm the diagnosis in case of negative result of SPT. However, the ID test is not recommended for cat and timothy grass allergy because of its high false positive rate. As a result, the "quantitative" technique of serum specific IgE (sIgE) measurement might be helpful to diagnose AR with more confidence. To evaluate the correlation between ID tests and sIgE in the diagnosis of house dust mite (HDM)-sensitive AR patients. Patients with chronic rhinitis (CR) were recruited and SPT was performed. If SPT was negative, ID test and sIgE to HDM [Dermatophagoides pteronyssinus (Dp)] measurement were performed. Eighty-two patients with chronic rhinitis (CR), whose SPTs were negative for Dp, were included. There were 39 males (47.6%) and 43 females (52.4%) aged between 18 and 76 years old (mean age = 43.3 years). The ID test was positive in 13 patients (15.9%), and was negative in 69 patients (84.1 %). sIgE to HDM was positive ( ≥ 0.35 kUA/l) in 2 patients (2.4%). There was a fair to moderate correlation between the size of wheal of ID test and sIgE to HDM (r = 0.44, 95% confidence interval: 0.19 to 0.67, p < 0.01). ID test has a fair to moderate correlation with sIgE Dermatophagoides pteronyssinus and it can be used in CR patients with negative SPT where sIgE is not feasible.

  18. Low HIV testing rate and its correlates among men who inject drugs in Iran.

    PubMed

    Shokoohi, Mostafa; Karamouzian, Mohammad; Osooli, Mehdi; Sharifi, Hamid; Fahimfar, Noushin; Haghdoost, AliAkbar; Zamani, Omid; Mirzazadeh, Ali

    2016-06-01

    Iran has a concentrated HIV epidemic among people who inject drugs (PWID). Low HIV testing uptake could contribute to the significant number HIV-infected PWID, who go undiagnosed. This study aims to assess HIV testing uptake and its correlates among PWID in Iran. Data were collected through a national cross-sectional bio-behavioral study in 2010. Adult male HIV-negative PWID were included in the current analysis. All estimates were adjusted for the clustering effect of the sampling sites. Multivariable logistic regression was used to examine the correlates of recent HIV testing and adjusted odds ratios (AOR) were reported. Out of the 2146 eligible PWID for this study, 49.8% reported having ever tested for HIV. However, only 24.9% had tested in the previous year and received their test results. Around 65.2% of PWID knew an HIV testing site. In the multivariable analysis, knowing an HIV testing site (AOR=13.9; P-value<0.001), ≥24 years of age (AOR=3.30; P-value=0.027), and multiple incarcerations (AOR=1.71; P-value<0.001) were positively, and a monthly income of ≥65 US dollar (AOR=0.23; P-value=0.009) was negatively associated with having been tested and received the results. Despite the availability of free HIV counselling and testing for PWID in Iran, only one-fourth of adult male PWID had been tested for HIV and received their results. Implementing policies and strategies to normalize routine HIV testing among PWID are crucial steps to help curb the epidemic among Iranian PWID. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Finite-Element Vibration Analysis and Modal Testing of Graphite Epoxy Tubes and Correlation Between the Data

    NASA Technical Reports Server (NTRS)

    Taleghani, Barmac K.; Pappa, Richard S.

    1996-01-01

    Structural materials in the form of graphite epoxy composites with embedded rubber layers are being used to reduce vibrations in rocket motor tubes. Four filament-wound, graphite epoxy tubes were studied to evaluate the effects of the rubber layer on the modal parameters (natural vibration frequencies, damping, and mode shapes). Tube 1 contained six alternating layers of 30-degree helical wraps and 90-degree hoop wraps. Tube 2 was identical to tube 1 with the addition of an embedded 0.030-inch-thick rubber layer. Tubes 3 and 4 were identical to tubes 1 and 2, respectively, with the addition of a Textron Kelpoxy elastomer. This report compares experimental modal parameters obtained by impact testing with analytical modal parameters obtained by NASTRAN finite-element analysis. Four test modes of tube 1 and five test modes of tube 3 correlate highly with corresponding analytical predictions. Unsatisfactory correlation of test and analysis results occurred for tubes 2 and 4 and these comparisons are not shown. Work is underway to improve the analytical models of these tubes. Test results clearly show that the embedded rubber layers significantly increase structural modal damping as well as decrease natural vibration frequencies.

  20. A Simple and Robust Statistical Test for Detecting the Presence of Recombination

    PubMed Central

    Bruen, Trevor C.; Philippe, Hervé; Bryant, David

    2006-01-01

    Recombination is a powerful evolutionary force that merges historically distinct genotypes. But the extent of recombination within many organisms is unknown, and even determining its presence within a set of homologous sequences is a difficult question. Here we develop a new statistic, Φw, that can be used to test for recombination. We show through simulation that our test can discriminate effectively between the presence and absence of recombination, even in diverse situations such as exponential growth (star-like topologies) and patterns of substitution rate correlation. A number of other tests, Max χ2, NSS, a coalescent-based likelihood permutation test (from LDHat), and correlation of linkage disequilibrium (both r2 and |D′|) with distance, all tend to underestimate the presence of recombination under strong population growth. Moreover, both Max χ2 and NSS falsely infer the presence of recombination under a simple model of mutation rate correlation. Results on empirical data show that our test can be used to detect recombination between closely as well as distantly related samples, regardless of the suspected rate of recombination. The results suggest that Φw is one of the best approaches to distinguish recurrent mutation from recombination in a wide variety of circumstances. PMID:16489234

  1. The study of human higher mental functions as they relate to neurophysiological processes and personal characteristics

    NASA Astrophysics Data System (ADS)

    Runnova, Anastasiya; Zhuravlev, Maxim; Kulanin, Roman; Protasov, Pavel; Hramov, Alexander; Koronovskii, Alexey

    2018-02-01

    In this paper we study the correlation between the neurophysiological processes and personal characteristics arising in the processes of human higher mental functions. We find that the activity of the brain correlates with the results of psychological tests (according to the Cattell test). Experimental studies and math processing are described for operation design with the registration of human multi-channel EEG data in two phases (the processes of passive wakefulness (background) and special psychological testing (active phase)).

  2. A Comparative Study of the Warrior Support Tool and the Agile Munitions Support Tool

    DTIC Science & Technology

    2003-03-01

    were conducted in order to test for suitability: a correlation matrix, Bartlett’s Test of Sphericity, the Kaiser - Meyer - Olkin Measure of Sampling...population is correlated. Another test, the Kaiser - Meyer - Olkin Measure (KMO) of sample Adequacy, yielded .727, .708, .722, .898, .721, .726, .886, and .864...54.864, 100.186, 68.835, 628.779, 99.868, 164.650, 220.543, and 247.348 with p-values of .000 for all the results. The Kaiser - Meyer - Olkin Measure of

  3. A Flight Prediction for Performance of the SWAS Solar Array Deployment Mechanism

    NASA Technical Reports Server (NTRS)

    Seniderman, Gary; Daniel, Walter K.

    1999-01-01

    The focus of this paper is a comparison of ground-based solar array deployment tests with the on-orbit deployment. The discussion includes a summary of the mechanisms involved and the correlation of a dynamics model with ground based test results. Some of the unique characteristics of the mechanisms are explained through the analysis of force and angle data acquired from the test deployments. The correlated dynamics model is then used to predict the performance of the system in its flight application.

  4. RESEARCH FOR THE AEROSPACE SYSTEMS DIRECTORATE (R4RQ) Delivery Order 0006: Airbreathing Propulsion Fuels and Energy Exploratory Research and Development (APFEERD) Sub Task: Review of Materials Compatibility Tests of Synthesized Hydrocarbon Kerosenes and Blends

    DTIC Science & Technology

    2017-07-31

    processing. Also, the presence of cyclo-paraffins and tetralins plus indans do not affect the fundamental correlation with aromatic content at the...processing. • The presence of cyclo-paraffins and tetralins plus indans do not affect the fundamental correlation with aromatic content at the...random, and shows no correlation with aromatic content. However, all of the test results were well above the minimum technical requirements of 200 psi

  5. Validation and cross-cultural pilot testing of compliance with standard precautions scale: self-administered instrument for clinical nurses.

    PubMed

    Lam, Simon C

    2014-05-01

    To perform detailed psychometric testing of the compliance with standard precautions scale (CSPS) in measuring compliance with standard precautions of clinical nurses and to conduct cross-cultural pilot testing and assess the relevance of the CSPS on an international platform. A cross-sectional and correlational design with repeated measures. Nursing students from a local registered nurse training university, nurses from different hospitals in Hong Kong, and experts in an international conference. The psychometric properties of the CSPS were evaluated via internal consistency, 2-week and 3-month test-retest reliability, concurrent validation, and construct validation. The cross-cultural pilot testing and relevance check was examined by experts on infection control from various developed and developing regions. Among 453 participants, 193 were nursing students, 165 were enrolled nurses, and 95 were registered nurses. The results showed that the CSPS had satisfactory reliability (Cronbach α = 0.73; intraclass correlation coefficient, 0.79 for 2-week test-retest and 0.74 for 3-month test-retest) and validity (optimum correlation with criterion measure; r = 0.76, P < .001; satisfactory results on known-group method and hypothesis testing). A total of 19 experts from 16 countries assured that most of the CSPS findings were relevant and globally applicable. The CSPS demonstrated satisfactory results on the basis of the standard international criteria on psychometric testing, which ascertained the reliability and validity of this instrument in measuring the compliance of clinical nurses with standard precautions. The cross-cultural pilot testing further reinforced the instrument's relevance and applicability in most developed and developing regions.

  6. Comparison of aerodynamic coefficients obtained from theoretical calculations wind tunnel tests and flight tests data reduction for the alpha jet aircraft

    NASA Technical Reports Server (NTRS)

    Guiot, R.; Wunnenberg, H.

    1980-01-01

    The methods by which aerodynamic coefficients are determined and discussed. These include: calculations, wind tunnel experiments and experiments in flight for various prototypes of the Alpha Jet. A comparison of obtained results shows good correlation between expectations and in-flight test results.

  7. System Identification of Damped Truss-Like Space Structures. Ph.D. Thesis - Cleveland State Univ., Mar. 1994

    NASA Technical Reports Server (NTRS)

    Armand, Sasan

    1995-01-01

    A spacecraft payload flown on a launch vehicle experiences dynamic loads. The dynamic loads are caused by various phenomena ranging from the start-up of the launch vehicle engine to wind gusts. A spacecraft payload should be designed to meet launch vehicle dynamic loads. One of the major steps taken towards determining the dynamic loads is to correlate the finite element model of the spacecraft with the test results of a modal survey test. A test-verified finite element model of the spacecraft should possess the same spatial properties (stiffness, mass, and damping) and modal properties (frequencies and mode shapes) as the test hardware representing the spacecraft. The test-verified and correlated finite element model of the spacecraft is then coupled with the finite element model of the launch vehicle for analysis of loads and stress. Modal survey testing, verification of a finite element model, and modification of the finite element model to match the modal survey test results can easily be accomplished if the spacecraft structure is simple. However, this is rarely the case. A simple structure here is defined as a structure where the influence of nonlinearity between force and displacement (uncertainty in a test, for example, with errors in input and output), and the influence of damping (structural, coulomb, and viscous) are not pronounced. The objective of this study is to develop system identification and correlation methods with the focus on the structural systems that possess nonproportional damping. Two approaches to correct the nonproportional damping matrix of a truss structure were studied, and have been implemented on truss-like structures such as the National Aeronautics and Space Administration's space station truss. The results of this study showed nearly 100 percent improvement of the correlated eigensystem over the analytical eigensystem. The first method showed excellent results with up to three modes used in the system identification process. The second method could handle more modes, but required more computer usage time, and the results were less accurate than those of the first method.

  8. Clinical Usefulness of the Pendulum Test Using a NK Table to Measure the Spasticity of Patients with Brain Lesions

    PubMed Central

    Kim, Yong-Wook

    2013-01-01

    . [Purpose] The purpose of the present study was to investigate the clinical usefulness (reliability and validity) of the pendulum test using a Noland-Kuckhoff (NK) table with an attached electrogoniometer to measure the spasticity of patients with brain lesions. [Subjects] The subjects were 31 patients with stroke or traumatic brain injury. [Methods] The intraclass correlation coefficient (ICC) was used to verify the test–retest reliability of spasticity measures obtained using the pendulum test. Pearson's product correlation coefficient was used to examine the validity of the pendulum test using the amplitude of the patellar tendon reflex (PTR) test, an objective and quantitative measure of spasticity. [Results] The test–retest reliability was high, reflecting a significant correlation between the test and the retest (ICCs = 0.95–0.97). A significant negative correlation was found between the amplitude of the PTR test and the four variables measured in the pendulum test (r = −0.77– −0.85). [Conclusion] The pendulum test using a NK table is an objective measure of spasticity and can be used in the clinical setting in place of more expensive and complicated equipment. Further studies are needed to investigate the therapeutic effect of this method on spasticity. PMID:24259775

  9. [Auditory and corporal laterality, logoaudiometry, and monaural hearing aid gain].

    PubMed

    Benavides, Mariela; Peñaloza-López, Yolanda R; de la Sancha-Jiménez, Sabino; García Pedroza, Felipe; Gudiño, Paula K

    2007-12-01

    To identify the auditory or clinical test that has the best correlation with the ear in which we apply the monaural hearing aid in symmetric bilateral hearing loss. A total of 37 adult patients with symmetric bilateral hearing loss were examined regarding the correlation between the best score in speech discrimination test, corporal laterality, auditory laterality with dichotic digits in Spanish and score for filtered words with monaural hearing aid. The best correlation was obtained between auditory laterality and gain with hearing aid (0.940). The dichotic test for auditory laterality is a good tool for identifying the best ear in which to apply a monaural hearing aid. The results of this paper suggest the necessity to apply this test in patients before a hearing aid is indicated.

  10. Microgravity Propellant Tank Geyser Analysis and Prediction

    NASA Technical Reports Server (NTRS)

    Thornton, Randall J.; Hochstein, John I.; Turner, James E. (Technical Monitor)

    2001-01-01

    An established correlation for geyser height prediction of an axial jet inflow into a microgravity propellant tank was analyzed and an effort to develop an improved correlation was made. The original correlation, developed using data from ethanol flow in small-scale drop tower tests, uses the jet-Weber number and the jet-Bond number to predict geyser height. A new correlation was developed from the same set of experimental data using the jet-Weber number and both the jet-Bond number and tank-Bond number to describe the geyser formation. The resulting correlation produced nearly a 40% reduction in geyser height predictive error compared to the original correlation with experimental data. Two additional tanks were computationally modeled in addition to the small-scale tank used in the drop tower testing. One of these tanks was a 50% enlarged small-scale tank and the other a full-scale 2 m radius tank. Simulations were also run for liquid oxygen and liquid hydrogen. Results indicated that the new correlation outperformed the original correlation in geyser height prediction under most circumstances. The new correlation has also shown a superior ability to recognize the difference between flow patterns II (geyser formation only) and III (pooling at opposite end of tank from the bulk fluid region).

  11. Oscillating-Flow Regenerator Test Rig: Hardware and Theory With Derived Correlations for Screens and Felts

    NASA Technical Reports Server (NTRS)

    Gedeon, D.; Wood, J. G.

    1996-01-01

    A number of wire mesh and metal felt test samples, with a range of porosities, yield generic correlations for friction factor, Nusselt number, enhanced axial conduction ratio, and overall heat flux ratio. This information is directed primarily toward stirling cycle regenerator modelers, but will be of use to anyone seeking to better model fluid flow through these porous materials. Behind these results lies an oscillating-flow test rig, which measures pumping dissipation and thermal energy transport in sample matrices, and several stages of data-reduction software, which correlate instantaneous values for the above dimensionless groups. Within the software, theoretical model reduces instantaneous quantifies from cycle-averaged measurables using standard parameter estimation techniques.

  12. Two-colour chewing gum mixing ability test for evaluating masticatory performance in children with mixed dentition: validity and reliability study.

    PubMed

    Kaya, M S; Güçlü, B; Schimmel, M; Akyüz, S

    2017-11-01

    The unappealing taste of the chewing material and the time-consuming repetitive task in masticatory performance tests using artificial foodstuff may discourage children from performing natural chewing movements. Therefore, the aim was to determine the validity and reliability of a two-colour chewing gum mixing ability test for masticatory performance (MP) assessment in mixed dentition children. Masticatory performance was tested in two groups: systemically healthy fully dentate young adults and children in mixed dentition. Median particle size was assessed using a comminution test, and a two-colour chewing gum mixing ability test was applied for MP analysis. Validity was tested with Pearson correlation, and reliability was tested with intra-class correlation coefficient, Pearson correlation and Bland-Altman plots. Both comminution and two-colour chewing gum mixing ability tests revealed statistically significant MP differences between children (n = 25) and adults (n = 27, both P < 0·01). Pearson correlation between comminution and two-colour chewing gum mixing ability tests was positive and significant (r = 0·418, P = 0·002). Correlations for interobserver reliability and test-retest values were significant (r = 0·990, P = 0·0001 and r = 0·995, P = 0·0001). Although both methods could discriminate MP differences, the comminution test detected these differences generally in a wider range compared to two-colour chewing gum mixing ability test. However, considering the high reliability of the results, the two-colour chewing gum mixing ability test can be used to assess masticatory performance in children, especially at non-clinical settings. © 2017 John Wiley & Sons Ltd.

  13. The beneficial effect of testing: an event-related potential study

    PubMed Central

    Bai, Cheng-Hua; Bridger, Emma K.; Zimmer, Hubert D.; Mecklinger, Axel

    2015-01-01

    The enhanced memory performance for items that are tested as compared to being restudied (the testing effect) is a frequently reported memory phenomenon. According to the episodic context account of the testing effect, this beneficial effect of testing is related to a process which reinstates the previously learnt episodic information. Few studies have explored the neural correlates of this effect at the time point when testing takes place, however. In this study, we utilized the ERP correlates of successful memory encoding to address this issue, hypothesizing that if the benefit of testing is due to retrieval-related processes at test then subsequent memory effects (SMEs) should resemble the ERP correlates of retrieval-based processing in their temporal and spatial characteristics. Participants were asked to learn Swahili-German word pairs before items were presented in either a testing or a restudy condition. Memory performance was assessed immediately and 1-day later with a cued recall task. Successfully recalling items at test increased the likelihood that items were remembered over time compared to items which were only restudied. An ERP subsequent memory contrast (later remembered vs. later forgotten tested items), which reflects the engagement of processes that ensure items are recallable the next day were topographically comparable with the ERP correlate of immediate recollection (immediately remembered vs. immediately forgotten tested items). This result shows that the processes which allow items to be more memorable over time share qualitatively similar neural correlates with the processes that relate to successful retrieval at test. This finding supports the notion that testing is more beneficial than restudying on memory performance over time because of its engagement of retrieval processes, such as the re-encoding of actively retrieved memory representations. PMID:26441577

  14. The relationship between intelligence and cognitive function in schizophrenic

    NASA Astrophysics Data System (ADS)

    Catherine; Amin, M. M.; Effendy, E.

    2018-03-01

    The most common of psychotic disorders is schizophrenia. While evaluating the cognitive function with a standardized test, the intelligence test is by using the IQ test. For schizophrenic patients, intelligence is usually reported to be lower than average. This research is an analytical study that commenced in January and ended in March 2014. Primary criteria are schizophrenics who are in-patients in Prof. dr. M. Ildrem Mental Hospital, aged between 15 to 55 years old, with the highest qualification of secondary high school. The secondary criteria are those patients with other psychotic disorders, head injuries and other neurological disorders, endocrine disorders. The total sample is 100 subjects. From this study, the correlation value is 0.876 shows a very strong correlation. And the p-value 0.001.The results of this study show that there is a direct correlation (p=0.001) and a correlation (r=0.876) between intelligence and cognitive function on schizophrenic. And it is also necessary to do more researches by using other rating scales and examination to measure the relationship between intelligence and cognitive function, and other factors that may affect results.

  15. Psycholinguistic Correlates of Progress in Literature of Students of Russian Vocational Training School

    ERIC Educational Resources Information Center

    Nuriakhmetov, Aidar

    2012-01-01

    The article describes psycholinguistic correlates of progress in literature, discovered on the basis of correlation analysis of grades, and results of several psychological and psycholinguistic tests were taken in the context of comprehensive psycholinguistic research based on one of Russian vocational training schools. Analysis revealed a list of…

  16. Application of High Speed Digital Image Correlation in Rocket Engine Hot Fire Testing

    NASA Technical Reports Server (NTRS)

    Gradl, Paul R.; Schmidt, Tim

    2016-01-01

    Hot fire testing of rocket engine components and rocket engine systems is a critical aspect of the development process to understand performance, reliability and system interactions. Ground testing provides the opportunity for highly instrumented development testing to validate analytical model predictions and determine necessary design changes and process improvements. To properly obtain discrete measurements for model validation, instrumentation must survive in the highly dynamic and extreme temperature application of hot fire testing. Digital Image Correlation has been investigated and being evaluated as a technique to augment traditional instrumentation during component and engine testing providing further data for additional performance improvements and cost savings. The feasibility of digital image correlation techniques were demonstrated in subscale and full scale hotfire testing. This incorporated a pair of high speed cameras to measure three-dimensional, real-time displacements and strains installed and operated under the extreme environments present on the test stand. The development process, setup and calibrations, data collection, hotfire test data collection and post-test analysis and results are presented in this paper.

  17. Relationship between isometric and dynamic strength in recreationally trained men.

    PubMed

    McGuigan, Michael R; Newton, Michael J; Winchester, Jason B; Nelson, Arnold G

    2010-09-01

    The purpose of this investigation was to examine the relationships between measures of maximal isometric force (peak force [PF]), rate of force development (RFD), vertical jump performance (VJ) and 1-repetition maximum (1RM) strength in recreationally trained men. The subjects in this study were 26 men ([mean +/- SD]: age 22 +/- 1 years; height 175 +/- 7 cm; mass 90 +/- 10 kg). They were tested for PF using the isometric midthigh pull exercise. The 1RM for the squat and bench press exercise were determined as a measure of dynamic strength. Explosive strength was measured as RFD from the isometric force-time curve. Correlations between the variables were calculated using Pearson product moment correlation coefficient. There was a nearly perfect correlation between measures of PF and 1RM squat (r = 0.97, p < 0.05) and 1RM bench press (r = 0.99, p < 0.05). The correlations were very strong between VJ and PF (r = 0.72, p < 0.05) and 1RM bench press (r = 0.70, p < 0.05). There were also strong correlations between VJ and 1RM squat (r = 0.69, p < 0.05). There were no significant correlations with RFD. The results showed that isometric maximum strength determined during the isometric midthigh pull test correlated well with 1RM and VJ testing. However, RFD measured during the same test did not appear to correlate as well with other measures. The isometric midthigh pull provides an efficient method for assessing strength in recreationally trained individuals. Practitioners wishing to obtain performance data related to maximum strength may wish to consider isometric testing as a less time intensive method of testing.

  18. Concordance analysis of paired cancer antigen (CA) 15-3 and 27.29 testing.

    PubMed

    Lin, David C; Genzen, Jonathan R

    2018-01-01

    Cancer antigens (CA) 15-3 and 27.29 are used in the clinical management of many breast cancer patients. Given that immunoassays for CA 15-3 and CA 27.29 target epitopes on the same glycoprotein-Mucin 1 (MUC1)-the present analysis was conducted to evaluate the potential concordance of tumor marker results when both tests were ordered by providers on the same specimens. A retrospective limited dataset of paired CA 15-3 (Roche Diagnostics) and CA 27.29 (Siemens Diagnostics) test results was obtained from a national clinical reference laboratory. Concordance according to reference interval (RI) status and percent (%) change between consecutive test results was analyzed. 37,652 paired results from 12,470 distinct patients were obtained. The correlation between CA 15-3 and CA 27.29 results was high (correlation coefficient: Pearson, 0.967), although across the dataset a significant difference between CA 15-3 and CA 27.29 results was observed (P < 0.05). RI concordance between CA 15-3 and CA 27.29 results was observed in 93.7% of pairs (35,280 of 37,652). Correlation was also observed in the % change of CA 15-3 and CA 27.29 results between consecutive specimens for individual patients. Using doubling or halving thresholds (i.e., 100% increase or 50% decrease), concordance in % change was observed between CA 15-3 and CA 27.29 in approximately 90% of cases. Individual patient results trended similarly across both markers over time. While generally concordant, CA 15-3 and CA 27.29 results should not be used interchangeably. The present report provides no evidence for added value in performing both tests routinely for individual patients.

  19. Monitoring ASA and P2Y12-specific platelet inhibition--comparison of conventional (single) and multiple electrode aggregometry.

    PubMed

    Krüger, Jan-Christopher; Meves, Saskia H; Kara, Kaffer; Mügge, Andreas; Neubauer, Horst

    2014-10-01

    Several platelet function test systems exist for the evaluation of the platelet inhibitory effect in patients on P2Y12 inhibitors and/or acetylsalicylic acid (ASA, aspirin) therapy. Studies comparing different available assays found only a poor correlation. The objective of the present study was to evaluate the correlation and agreement between single electrode (SEA) and multiple electrode (MEA) aggregometry. In whole blood arachidonic acid (AA) and adenosine diphosphate (ADP)-induced platelet aggregation was measured simultaneously using SEA (Chrono-Log) and MEA (Multiplate). We analyzed a total of 226 measurements taken from 58 patients on single ASA therapy or dual antiplatelet therapy with ASA and a thienopyridine. A cut-off value for clopidogrel/prasugrel high on-treatment platelet reactivity (HPR) of > 47 units (U) was chosen for MEA testing using hirudin and > 5 Ohm for SEA with citrate anticoagulated blood samples. The respective cut-off values for ASA HPR were > 30 U for the MEA assay and > 1 Ohm for SEA testing. There was a good correlation of the prevalence of thienopyridine-HPR in both whole blood assays (Spearman rank correlation coefficient r = 0.698) and a good inter-rate accordance (Cohen's Kappa statistic κ = 0.648). For AA-induced aggregation, the correlation of the results obtained was significant (r = 0.536; p < 0.001) and detecting ASA-HPR revealed a moderate (κ = 0.482) correlation between both impedance aggregometry assays. Platelet function testing using SEA and MEA provided both good accordance and correlation and therefore study results obtained by these two assays similarly enabled the detection of HPR of thienopyridine (and ASA) therapy.

  20. Role of electron concentration in softening and hardening of ternary molybdenum alloys

    NASA Technical Reports Server (NTRS)

    Stephens, J. R.; Witzke, W. R.

    1975-01-01

    Effects of various combinations of hafnium, tantalum, rhenium, osmium, iridium, and platinum in ternary molybdenum alloys on alloy softening and hardening were determined. Hardness tests were conducted at four test temperatures over the temperature range 77 to 411 K. Results showed that hardness data for ternary molybdenum alloys could be correlated with anticipated results from binary data based upon expressions involving the number of s and d electrons contributed by the solute elements. The correlation indicated that electron concentration plays a dominant role in controlling the hardness of ternary molybdenum alloys.

  1. Psychometric characteristics of Clinical Reasoning Problems (CRPs) and its correlation with routine multiple choice question (MCQ) in Cardiology department

    PubMed Central

    DERAKHSHANDEH, ZAHRA; AMINI, MITRA; KOJURI, JAVAD; DEHBOZORGIAN, MARZIYEH

    2018-01-01

    Introduction: Clinical reasoning is one of the most important skills in the process of training a medical student to become an efficient physician. Assessment of the reasoning skills in a medical school program is important to direct students’ learning. One of the tests for measuring the clinical reasoning ability is Clinical Reasoning Problems (CRPs). The major aim of this study is to measure psychometric qualities of CRPs and define correlation between this test and routine MCQ in cardiology department of Shiraz medical school. Methods: This study was a descriptive study conducted on total cardiology residents of Shiraz Medical School. The study population consists of 40 residents in 2014. The routine CRPs and the MCQ tests was designed based on similar objectives and were carried out simultaneously. Reliability, item difficulty, item discrimination, and correlation between each item and the total score of CRPs were all measured by Excel and SPSS software for checking psycometeric CRPs test. Furthermore, we calculated the correlation between CRPs test and MCQ test. The mean differences of CRPs test score between residents’ academic year [second, third and fourth year] were also evaluated by Analysis of variances test (One Way ANOVA) using SPSS software (version 20)(α=0.05). Results: The mean and standard deviation of score in CRPs was 10.19 ±3.39 out of 20; in MCQ, it was 13.15±3.81 out of 20. Item difficulty was in the range of 0.27-0.72; item discrimination was 0.30-0.75 with question No.3 being the exception (that was 0.24). The correlation between each item and the total score of CRP was 0.26-0.87; the correlation between CRPs test and MCQ test was 0.68 (p<0.001). The reliability of the CRPs was 0.72 as calculated by using Cronbach's alpha. The mean score of CRPs was different among residents based on their academic year and this difference was statistically significant (p<0.001). Conclusion: The results of this present investigation revealed that CRPs could be reliable test for measuring clinical reasoning in residents. It can be included in cardiology residency assessment programs. PMID:29344528

  2. A reassessment of the in vitro RBC haemolysis assay with defibrinated sheep blood for the determination of the ocular irritation potential of cosmetic products: comparison with the in vivo Draize rabbit test.

    PubMed

    Alves, Eloísa Nunes; Presgrave, Rosaura de Farias; Presgrave, Octávio Augusto França; Sabagh, Fernanda Peres; de Freitas, João Carlos Borges Rolim; Corrado, Alexandre P

    2008-07-01

    We examined the correlation between results obtained from the in vivo Draize test for ocular irritation and in vitro results obtained from the sheep red blood cell (RBC) haemolytic assay, which assesses haemolysis and protein denaturation in erythrocytes, induced by cosmetic products. We sought to validate the haemolytic assay as a preliminary test for identifying highly-irritative products, and also to evaluate the in vitro test as alternative assay for replacement of the in vivo test. In vitro and in vivo analyses were carried out on 19 cosmetic products, in order to correlate the lesions in the ocular structures with three in vitro parameters: (i) the extent of haemolysis (H50); (ii) the protein denaturation index (DI); and (iii) the H50/DI ratio, which reflects the irritation potential (IP). There was significant correlation between maximum average scores (MAS) and the parameters determined in vitro (r = 0.752-0.764). These results indicate that the RBC assay is a useful and rapid test for use as a screening method to assess the IP of cosmetic products, and for predicting the IP value with a high level of concordance (94.7%). The assay showed high sensitivity and specificity rates of 91.6% and 100%, respectively.

  3. Accelerated Test Method for Corrosion Protective Coatings Project

    NASA Technical Reports Server (NTRS)

    Falker, John; Zeitlin, Nancy; Calle, Luz

    2015-01-01

    This project seeks to develop a new accelerated corrosion test method that predicts the long-term corrosion protection performance of spaceport structure coatings as accurately and reliably as current long-term atmospheric exposure tests. This new accelerated test method will shorten the time needed to evaluate the corrosion protection performance of coatings for NASA's critical ground support structures. Lifetime prediction for spaceport structure coatings has a 5-year qualification cycle using atmospheric exposure. Current accelerated corrosion tests often provide false positives and negatives for coating performance, do not correlate to atmospheric corrosion exposure results, and do not correlate with atmospheric exposure timescales for lifetime prediction.

  4. Only Behavioral But Not Self-Report Measures of Speech Perception Correlate with Cognitive Abilities.

    PubMed

    Heinrich, Antje; Henshaw, Helen; Ferguson, Melanie A

    2016-01-01

    Good speech perception and communication skills in everyday life are crucial for participation and well-being, and are therefore an overarching aim of auditory rehabilitation. Both behavioral and self-report measures can be used to assess these skills. However, correlations between behavioral and self-report speech perception measures are often low. One possible explanation is that there is a mismatch between the specific situations used in the assessment of these skills in each method, and a more careful matching across situations might improve consistency of results. The role that cognition plays in specific speech situations may also be important for understanding communication, as speech perception tests vary in their cognitive demands. In this study, the role of executive function, working memory (WM) and attention in behavioral and self-report measures of speech perception was investigated. Thirty existing hearing aid users with mild-to-moderate hearing loss aged between 50 and 74 years completed a behavioral test battery with speech perception tests ranging from phoneme discrimination in modulated noise (easy) to words in multi-talker babble (medium) and keyword perception in a carrier sentence against a distractor voice (difficult). In addition, a self-report measure of aided communication, residual disability from the Glasgow Hearing Aid Benefit Profile, was obtained. Correlations between speech perception tests and self-report measures were higher when specific speech situations across both were matched. Cognition correlated with behavioral speech perception test results but not with self-report. Only the most difficult speech perception test, keyword perception in a carrier sentence with a competing distractor voice, engaged executive functions in addition to WM. In conclusion, any relationship between behavioral and self-report speech perception is not mediated by a shared correlation with cognition.

  5. Do scores on a tachistoscope test correlate with baseball batting averages?

    PubMed

    Reichow, Alan W; Garchow, Kenneth E; Baird, Richard Y

    2011-05-01

    Millions of dollars are spent each year by individuals seeking to improve their athletic performance. One area of visual training is the use of the tachistoscope, which measures inspection time or visual recognition time. Although the potential of the tachistoscope as a training tool has received some research attention, its use as a means of measurement or predictor of athletic ability in sports has not been explored. The purpose of this pilot study is to assess the potential of the tachistoscope as a measurement instrument by determining if a baseball player's ability to identify a tachistoscopically presented picture of a pitch is correlated with hitting performance as measured by batting average. Using sport-specific slides, 20 subjects-all non-pitching members of the Pacific University Baseball Team-were administered a tachistoscopic test. The test consisted of identifying the type of pitch illustrated in 30 randomly ordered slides depicting a pitcher throwing four different baseball pitches. Each slide was presented for 0.2 sec. The results of the test were compared with the athlete's previous season's batting average. A positive correlation was found between an athlete's ability to correctly identify a picture of a pitch presented tachistoscopically and batting average (r=0.648; P<0.01). These results suggest that a superior ability to recognize pitches presented via tachistoscope may correlate with a higher skill level in batting. Tachistoscopic test scores correlated positively with batting averages. The tachistoscope may be an acceptable tool to help in assessing batting performance. Additional testing with players from different sports, different levels of ability, and different tachistoscopic times should be performed to determine if the tachistoscope is a valid measure of athletic ability. Implications may also be drawn in other areas such as military and police work.

  6. Only Behavioral But Not Self-Report Measures of Speech Perception Correlate with Cognitive Abilities

    PubMed Central

    Heinrich, Antje; Henshaw, Helen; Ferguson, Melanie A.

    2016-01-01

    Good speech perception and communication skills in everyday life are crucial for participation and well-being, and are therefore an overarching aim of auditory rehabilitation. Both behavioral and self-report measures can be used to assess these skills. However, correlations between behavioral and self-report speech perception measures are often low. One possible explanation is that there is a mismatch between the specific situations used in the assessment of these skills in each method, and a more careful matching across situations might improve consistency of results. The role that cognition plays in specific speech situations may also be important for understanding communication, as speech perception tests vary in their cognitive demands. In this study, the role of executive function, working memory (WM) and attention in behavioral and self-report measures of speech perception was investigated. Thirty existing hearing aid users with mild-to-moderate hearing loss aged between 50 and 74 years completed a behavioral test battery with speech perception tests ranging from phoneme discrimination in modulated noise (easy) to words in multi-talker babble (medium) and keyword perception in a carrier sentence against a distractor voice (difficult). In addition, a self-report measure of aided communication, residual disability from the Glasgow Hearing Aid Benefit Profile, was obtained. Correlations between speech perception tests and self-report measures were higher when specific speech situations across both were matched. Cognition correlated with behavioral speech perception test results but not with self-report. Only the most difficult speech perception test, keyword perception in a carrier sentence with a competing distractor voice, engaged executive functions in addition to WM. In conclusion, any relationship between behavioral and self-report speech perception is not mediated by a shared correlation with cognition. PMID:27242564

  7. The Correlations between Airport Sustainability and Indonesian Economic Growth

    NASA Astrophysics Data System (ADS)

    Setiawan, M. I.; Dhaniarti, I.; Utomo, W. M.; Sukoco, A.; Mudjanarko, S. W.; Hasyim, C.; Prasetijo, J.; Kurniasih, N.; Wajdi, M. B. N.; Purworusmiardi, T.; Suyono, J.; Sudapet, I. N.; Nasihien, R. D.; Wulandari, D. A. R.; Ade, R. T.; Atmaja, W. M. T.; Sugeng; Wulandari, A.

    2018-04-01

    This study aims to analyze the correlation between airport performances with Gross domestic product-regional (GDP-regional) performance. This research uses quantitative research method with correlation study approach. Based on the T-Value Test Result, the T-value for the Airport Performance variable is 14,264. T-Value Test Results and compared with T-table equal to 1,976 (significant level 0,05) hence T-count> T-table so variable of Airport Perform predicted have significant correlation to GDP-regional. This means that good airport performance will either improve the performance of Water supply, Sewerage, Waste Management and Remediation Activities; Wholesale and Retail Trade; Repair of Motor Vehicles and Motorcycles; Accommodation and Food Service Activities; Financial and Insurance Activities; Business Activities; Public Administration and Defence; Compulsory Social Security; Education; Human Health and Social Work Activities; Other Services Activities; Manufacturing; and Electricity and Gas, better.

  8. Wire Crimp Connectors Verification using Ultrasonic Inspection

    NASA Technical Reports Server (NTRS)

    Cramer, K. Elliott; Perey, Daniel F.; Yost, William T.

    2007-01-01

    The development of a new ultrasonic measurement technique to quantitatively assess wire crimp connections is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp connector and wire is shown to correlate with the results of a destructive pull test, which previously has been used to assess crimp wire junction quality. Various crimp junction pathologies (missing wire strands, incorrect wire gauge, incomplete wire insertion in connector) are ultrasonically tested, and their results are correlated with pull tests. Results show that the ultrasonic measurement technique consistently (as evidenced with pull-testing data) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying the technique while wire crimps are installed is also presented.

  9. Using Response Surface Methods to Correlate the Modal Test of an Inflatable Test Article

    NASA Technical Reports Server (NTRS)

    Gupta, Anju

    2013-01-01

    This paper presents a practical application of response surface methods (RSM) to correlate a finite element model of a structural modal test. The test article is a quasi-cylindrical inflatable structure which primarily consists of a fabric weave, with an internal bladder and metallic bulkheads on either end. To mitigate model size, the fabric weave was simplified by representing it with shell elements. The task at hand is to represent the material behavior of the weave. The success of the model correlation is measured by comparing the four major modal frequencies of the analysis model to the four major modal frequencies of the test article. Given that only individual strap material properties were provided and material properties of the overall weave were not available, defining the material properties of the finite element model became very complex. First it was necessary to determine which material properties (modulus of elasticity in the hoop and longitudinal directions, shear modulus, Poisson's ratio, etc.) affected the modal frequencies. Then a Latin Hypercube of the parameter space was created to form an efficiently distributed finite case set. Each case was then analyzed with the results input into RSM. In the resulting response surface it was possible to see how each material parameter affected the modal frequencies of the analysis model. If the modal frequencies of the analysis model and its corresponding parameters match the test with acceptable accuracy, it can be said that the model correlation is successful.

  10. Types of Sensory Integrative Dysfunction among Disabled Learners

    ERIC Educational Resources Information Center

    Ayres, A. Jean

    1972-01-01

    R-technique factor analysis was used to correlate results of sensorimotor, psycholinguistic and cognitive tests given to California children with learning disabilities. Results show not all children with specific neural disorders perform poorly on related tests where low scores would be expected. (PD)

  11. Status of the Correlation Process of the V-HAB Simulation with Ground Tests and ISS Telemetry Data

    NASA Technical Reports Server (NTRS)

    Ploetner, Peter; Anderson, Molly S.; Czupalla, Markus; Ewert, Micahel K.; Roth, Christof Martin; Zhulov, Anton

    2012-01-01

    The Virtual Habitat (V-HAB) is a dynamic Life Support System (LSS) simulation, created to investigate future human spaceflight missions. V-HAB provides the capability to optimize LSS during early design phases. Furthermore, it allows simulation of worst case scenarios which cannot be tested in reality. In a nutshell, the tool allows the testing of LSS robustness by means of computer simulations. V-HAB is a modular simulation consisting of a: 1. Closed Environment Module 2. Crew Module 3. Biological Module 4. Physio-Chemical Module The focus of the paper will be the correlation and validation of V-HAB against ground test and flight data. The ECLSS technologies (CDRA, CCAA, OGA, etc.) are correlated one by one against available ground test data, which is briefly described in this paper. The technology models in V-HAB are merged to simulate the ISS ECLSS. This simulation is correlated against telemetry data from the ISS, including the water recovery system and the air revitalization system. Finally, an analysis of the results is included in this paper.

  12. Design and test of a 2m x 4m DART system

    NASA Technical Reports Server (NTRS)

    Tolomeo, J.; Loane, J.; Cross, G.; Tenerelli, D.; Sable, B.; Decker, T.; Nelson, T.; Joseph, B.; Windes, C.; Kokawa, D.; hide

    2003-01-01

    A 2 meter by 4 meter DART (dual anamorphic reflector telescope) system has been designed and fabricated using thin stretched mesh reflectors. This report documents the structural configuration, test preparation, test results, and analysis correlation.

  13. An empirical comparison of methods for analyzing correlated data from a discrete choice survey to elicit patient preference for colorectal cancer screening

    PubMed Central

    2012-01-01

    Background A discrete choice experiment (DCE) is a preference survey which asks participants to make a choice among product portfolios comparing the key product characteristics by performing several choice tasks. Analyzing DCE data needs to account for within-participant correlation because choices from the same participant are likely to be similar. In this study, we empirically compared some commonly-used statistical methods for analyzing DCE data while accounting for within-participant correlation based on a survey of patient preference for colorectal cancer (CRC) screening tests conducted in Hamilton, Ontario, Canada in 2002. Methods A two-stage DCE design was used to investigate the impact of six attributes on participants' preferences for CRC screening test and willingness to undertake the test. We compared six models for clustered binary outcomes (logistic and probit regressions using cluster-robust standard error (SE), random-effects and generalized estimating equation approaches) and three models for clustered nominal outcomes (multinomial logistic and probit regressions with cluster-robust SE and random-effects multinomial logistic model). We also fitted a bivariate probit model with cluster-robust SE treating the choices from two stages as two correlated binary outcomes. The rank of relative importance between attributes and the estimates of β coefficient within attributes were used to assess the model robustness. Results In total 468 participants with each completing 10 choices were analyzed. Similar results were reported for the rank of relative importance and β coefficients across models for stage-one data on evaluating participants' preferences for the test. The six attributes ranked from high to low as follows: cost, specificity, process, sensitivity, preparation and pain. However, the results differed across models for stage-two data on evaluating participants' willingness to undertake the tests. Little within-patient correlation (ICC ≈ 0) was found in stage-one data, but substantial within-patient correlation existed (ICC = 0.659) in stage-two data. Conclusions When small clustering effect presented in DCE data, results remained robust across statistical models. However, results varied when larger clustering effect presented. Therefore, it is important to assess the robustness of the estimates via sensitivity analysis using different models for analyzing clustered data from DCE studies. PMID:22348526

  14. Statistical core design methodology using the VIPRE thermal-hydraulics code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lloyd, M.W.; Feltus, M.A.

    1994-12-31

    This Penn State Statistical Core Design Methodology (PSSCDM) is unique because it not only includes the EPRI correlation/test data standard deviation but also the computational uncertainty for the VIPRE code model and the new composite box design correlation. The resultant PSSCDM equation mimics the EPRI DNBR correlation results well, with an uncertainty of 0.0389. The combined uncertainty yields a new DNBR limit of 1.18 that will provide more plant operational flexibility. This methodology and its associated correlation and uniqe coefficients are for a very particular VIPRE model; thus, the correlation will be specifically linked with the lumped channel and subchannelmore » layout. The results of this research and methodology, however, can be applied to plant-specific VIPRE models.« less

  15. [Performance and personality of patients with hypersomnia].

    PubMed

    Mayer, G; Leonhardt, E

    1996-01-01

    5 groups of patients with hypersomnia (narcolepsy, posttraumatic, psychophysiologic, idiopathic hypersomnia and circadian sleep-wake disorders) were tested with a battery of psychometric tests (FPI, MMPI, BVND, BIV, Benton, d2, WIP), visual vigilance test, polysomnography and MSLT in order to investigate the context between personality and performance. MSLT showed a range from clear pathologic to borderline sleep latencies among all groups, only patients with posttraumatic hypersomnia and narcolepsy displayed sleep onset REM. Correct results of vigilance tests correlated negatively with performance-motivation and orientation in patients with narcolepsy and posttraumatic hypersomnia, whereas there was positive correlation for patients with idiopathic hypersomnia. In patients with psychophysiologic hypersomnia performance orientation and false reactions correlate negatively. Patients with posttraumatic hypersomnia have better results on d2. Benton and vigilance tests than all other groups. Results of personality diagnosis are similar to those of healthy subjects, while patients with psychophysiologic hypersomnia are more sensible than all other groups with high social fears and the highest disposition among all groups toward somatic complaints. Patients with idiopathic hypersomnia show strong introversion and inhibition. Patients with circadian sleep-wake disorders display the most striking personality disorders, which are most probably sequelae of their strong disease-dependent impairment. The degree of personality disorder seems to be strongly dependent on the duration of the hypersomnias. The assessment of the whole set of tests can only be recommended for patients with psychophysiologic hypersomnia and circadian sleep-wake disorders, a few tests suffice to describe the other groups.

  16. Local cerebral glucose metabolism in patients with long-term behavioral and cognitive deficits following mild traumatic brain injury.

    PubMed

    Gross, H; Kling, A; Henry, G; Herndon, C; Lavretsky, H

    1996-01-01

    A retrospective study of 20 patients with mild traumatic brain injury (MTBI) examined brain regions of interest by comparing [18F]-2-deoxyglucose PET, neuropsychological test results, and continuing behavioral dysfunction. Abnormal local cerebral metabolic rates (rLCMs) were most prominent in midtemporal, anterior cingulate, precuneus, anterior temporal, frontal white, and corpus callosum brain regions. Abnormal rLCMs were significantly correlated statistically with 1) overall clinical complaints, most specifically with inconsistent attention/concentration and 2) overall neuropsychological test results. The authors conclude that 1) even mild TBI may result in continuing brain behavioral deficits; 2) PET can help elucidate dysfunctional brain circuitry in neurobehavioral disorders; and 3) specific brain areas may correlate with deficits in daily neurobehavioral functioning and neuropsychological test findings.

  17. Correlation between plasma endothelin-1 levels and severity of septic liver failure quantified by maximal liver function capacity (LiMAx test). A prospective study

    PubMed Central

    Kaffarnik, Magnus F.; Ahmadi, Navid; Lock, Johan F.; Wuensch, Tilo; Pratschke, Johann; Stockmann, Martin; Malinowski, Maciej

    2017-01-01

    Aim To investigate the relationship between the degree of liver dysfunction, quantified by maximal liver function capacity (LiMAx test) and endothelin-1, TNF-α and IL-6 in septic surgical patients. Methods 28 septic patients (8 female, 20 male, age range 35–80y) were prospectively investigated on a surgical intensive care unit. Liver function, defined by LiMAx test, and measurements of plasma levels of endothelin-1, TNF-α and IL-6 were carried out within the first 24 hours after onset of septic symptoms, followed by day 2, 5 and 10. Patients were divided into 2 groups (group A: LiMAx ≥100 μg/kg/h, moderate liver dysfunction; group B: LiMAx <100 μg/kg/h, severe liver dysfunction) for analysis and investigated regarding the correlation between endothelin-1 and the severity of liver failure, quantified by LiMAx test. Results Group B showed significant higher results for endothelin-1 than patients in group A (P = 0.01, d5; 0.02, d10). For TNF-α, group B revealed higher results than group A, with a significant difference on day 10 (P = 0.005). IL-6 showed a non-significant trend to higher results in group B. The Spearman's rank correlation coefficient revealed a significant correlation between LiMAx and endothelin-1 (-0.434; P <0.001), TNF-α (-0.515; P <0.001) and IL-6 (-0.590; P <0.001). Conclusions Sepsis-related hepatic dysfunction is associated with elevated plasma levels of endothelin-1, TNF-α and IL-6. Low LiMAx results combined with increased endothelin-1 and TNF-α and a favourable correlation between LiMAx and cytokine values support the findings of a crucial role of Endothelin-1 and TNF-α in development of septic liver failure. PMID:28542386

  18. Relations between Eastern Four Pillars Theory and Western Measures of Personality Traits

    PubMed Central

    Jung, Seung Ah

    2015-01-01

    Purpose The present study investigated the validity of personality classification using four pillars theory, a tradition in China and northeastern Asia. Materials and Methods Four pillars analyses were performed for 148 adults on the basis of their birth year, month, day, and hour. Participants completed two personality tests, the Korean version of Temperament and Character Inventory-Revised-Short Version (TCI) and the Korean Inventory of Interpersonal Problems; scores were correlated with four pillars classification elements. Mean difference tests (e.g., t-test, ANOVA) were compared with groups classified by four pillars index. Results There were no significant correlations between personality scale scores and total yin/yang number (i.e., the 8 heavenly or earthly stems), and no significant between-groups results for classifications by yin/yang day stem and the five elements. There were significant but weak (r=0.18-0.29) correlations between the five elements and personality scale scores. For the six gods and personality scales, there were significant but weak (r=0.18-0.25) correlations. Features predicted by four pillars theory were most consistent when participants were grouped according to the yin/yang of the day stem and dominance of yin/yang numbers in the eight heavenly or earthly stems. Conclusion Although the major criteria of four pillars theory were not independently correlated with personality scale scores, correlations emerged when participants were grouped according to the composite yin/yang variable. Our results suggest the utility of four pillars theory (beyond fortune telling or astrology) for classifying personality traits and making behavioral predictions. PMID:25837175

  19. Quantitative measurement of HER2 expression in breast cancers: comparison with 'real-world' routine HER2 testing in a multicenter Collaborative Biomarker Study and correlation with overall survival.

    PubMed

    Yardley, Denise A; Kaufman, Peter A; Huang, Weidong; Krekow, Lea; Savin, Michael; Lawler, William E; Zrada, Stephen; Starr, Alexander; Einhorn, Harvey; Schwartzberg, Lee S; Adams, John W; Lie, Yolanda; Paquet, Agnes C; Sperinde, Jeff; Haddad, Mojgan; Anderson, Steve; Brigino, Marlon; Pesano, Rick; Bates, Michael P; Weidler, Jodi; Bosserman, Linda

    2015-03-18

    Accurate assessment of HER2 status is critical in determining appropriate therapy for breast cancer patients but the best HER2 testing methodology has yet to be defined. In this study, we compared quantitative HER2 expression by the HERmark™ Breast Cancer Assay (HERmark) with routine HER2 testing by immunohistochemistry (IHC) and fluorescence in situ hybridization (FISH), and correlated HER2 results with overall survival (OS) of breast cancer patients in a multicenter Collaborative Biomarker Study (CBS). Two hundred and thirty-two formalin-fixed, paraffin-embedded breast cancer tissues and local laboratory HER2 testing results were provided by 11 CBS sites. HERmark assay and central laboratory HER2 IHC retesting were retrospectively performed in a blinded fashion. HER2 results by all testing methods were obtained in 192 cases. HERmark yielded a continuum of total HER2 expression (H2T) ranging from 0.3 to 403 RF/mm2 (approximately 3 logs). The distribution of H2T levels correlated significantly (P<0.0001) with all routine HER2 testing results. The concordance of positive and negative values (equivocal cases excluded) between HERmark and routine HER2 testing was 84% for local IHC, 96% for central IHC, 85% for local FISH, and 84% for local HER2 status. OS analysis revealed a significant correlation of shorter OS with HER2 positivity by local IHC (HR=2.6, P=0.016), central IHC (HR=3.2, P=0.015), and HERmark (HR=5.1, P<0.0001) in this cohort of patients most of whom received no HER2-targeted therapy. The OS curve of discordant low (HER2 positive but H2T low, 10% of all cases) was aligned with concordant negative (HER2 negative and H2T low, HR=1.9, P=0.444), but showed a significantly longer OS than concordant positive (HER2 positive and H2T high, HR=0.31, P=0.024). Conversely, the OS curve of discordant high (HER2 negative but H2T high, 9% of all cases) was aligned with concordant positive (HR=0.41, P=0.105), but showed a significantly shorter OS than concordant negative (HR=41, P<0.0001). Quantitative HER2 measurement by HERmark is highly sensitive, accurately quantifies HER2 protein expression and correlates well with routine HER2 testing. When HERmark and local HER2 results were discordant, HERmark more accurately predicted overall survival.

  20. International Space Station Model Correlation Analysis

    NASA Technical Reports Server (NTRS)

    Laible, Michael R.; Fitzpatrick, Kristin; Hodge, Jennifer; Grygier, Michael

    2018-01-01

    This paper summarizes the on-orbit structural dynamic data and the related modal analysis, model validation and correlation performed for the International Space Station (ISS) configuration ISS Stage ULF7, 2015 Dedicated Thruster Firing (DTF). The objective of this analysis is to validate and correlate the analytical models used to calculate the ISS internal dynamic loads and compare the 2015 DTF with previous tests. During the ISS configurations under consideration, on-orbit dynamic measurements were collected using the three main ISS instrumentation systems; Internal Wireless Instrumentation System (IWIS), External Wireless Instrumentation System (EWIS) and the Structural Dynamic Measurement System (SDMS). The measurements were recorded during several nominal on-orbit DTF tests on August 18, 2015. Experimental modal analyses were performed on the measured data to extract modal parameters including frequency, damping, and mode shape information. Correlation and comparisons between test and analytical frequencies and mode shapes were performed to assess the accuracy of the analytical models for the configurations under consideration. These mode shapes were also compared to earlier tests. Based on the frequency comparisons, the accuracy of the mathematical models is assessed and model refinement recommendations are given. In particular, results of the first fundamental mode will be discussed, nonlinear results will be shown, and accelerometer placement will be assessed.

  1. Correlation of Three Techniques for Determining Soil Permeability

    ERIC Educational Resources Information Center

    Winneberger, John T.

    1974-01-01

    Discusses problems of acquiring adequate results when measuring for soil permeability. Correlates three relatively simple techniques that could be helpful to the inexperienced technician dealing with septic tank practices. An appendix includes procedures for valid percolation tests. (MLB)

  2. Dizziness Handicap Inventory and Visual Vertigo Analog Scale in Vestibular Dysfunction

    PubMed Central

    Grigol, Thaís Alvares de Abreu e Silva; Silva, Adriana Marques; Ferreira, Maristela Mian; Manso, Andrea; Ganança, Maurício Malavasi; Caovilla, Heloisa Helena

    2015-01-01

    Introduction  Dizziness is one of the most common symptoms among the population, producing numerous consequences for individual's quality of life. There are some questionnaires that can trace the patient's profile and quality of life impairment from dizziness, including the Dizziness Handicap Inventory (DHI) and the Visual Vertigo Analogue Scale (VVAS). Objective  This study aims to correlate the results of the DHI and VVAS in patients with vestibular dysfunction. Methods  This is a retrospective study of medical records of patients treated in a medical school between 2006 and 2012. Results of the DHI and EVA were collected and subjected to statistical analysis using Pearson's correlation test with p < 0.001. The significance level adopted for the statistical tests was p ≤ 0.05. Results  A total of 91 records were included in this study, 72 (79.1%) from female and 19 (20.9%) from male patients, aged 23 to 86 years, with a mean age of 52.5 years. The mean score on the DHI total was 43.9 and 5.2 points for the EVA. The result of Pearson's correlation test was 0.54. Conclusion  Self-perceived dizziness measured with the Dizziness Handicap Inventory has a regular and positive correlation with the Visual Vertigo Analog Scale in patients with vestibular dysfunction. The clinical trial is registered under number UTN U1111–1170–5065. PMID:27413406

  3. Validation study of an electronic method of condensed outcomes tools reporting in orthopaedics.

    PubMed

    Farr, Jack; Verma, Nikhil; Cole, Brian J

    2013-12-01

    Patient-reported outcomes (PRO) instruments are a vital source of data for evaluating the efficacy of medical treatments. Historically, outcomes instruments have been designed, validated, and implemented as paper-based questionnaires. The collection of paper-based outcomes information may result in patients becoming fatigued as they respond to redundant questions. This problem is exacerbated when multiple PRO measures are provided to a single patient. In addition, the management and analysis of data collected in paper format involves labor-intensive processes to score and render the data analyzable. Computer-based outcomes systems have the potential to mitigate these problems by reformatting multiple outcomes tools into a single, user-friendly tool.The study aimed to determine whether the electronic outcomes system presented produces results comparable with the test-retest correlations reported for the corresponding orthopedic paper-based outcomes instruments.The study is designed as a crossover study based on consecutive orthopaedic patients arriving at one of two designated orthopedic knee clinics.Patients were assigned to complete either a paper or a computer-administered questionnaire based on a similar set of questions (Knee injury and Osteoarthritis Outcome Score, International Knee Documentation Committee form, 36-Item Short Form survey, version 1, Lysholm Knee Scoring Scale). Each patient completed the same surveys using the other instrument, so that all patients had completed both paper and electronic versions. Correlations between the results from the two modes were studied and compared with test-retest data from the original validation studies.The original validation studies established test-retest reliability by computing correlation coefficients for two administrations of the paper instrument. Those correlation coefficients were all in the range of 0.7 to 0.9, which was deemed satisfactory. The present study computed correlation coefficients between the paper and electronic modes of administration. These correlation coefficients demonstrated similar results with an overall value of 0.86.On the basis of the correlation coefficients, the electronic application of commonly used knee outcome scores compare variably to the traditional paper variants with a high rate of test-retest correlation. This equivalence supports the use of the condensed electronic outcomes system and validates comparison of scores between electronic and paper modes. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  4. 20 Meter Solar Sail Analysis and Correlation

    NASA Technical Reports Server (NTRS)

    Taleghani, B.; Lively, P.; Banik, J.; Murphy, D.; Trautt, T.

    2005-01-01

    This presentation discusses studies conducted to determine the element type and size that best represents a 20-meter solar sail under ground-test load conditions, the performance of test/Analysis correlation by using Static Shape Optimization Method for Q4 sail, and system dynamic. TRIA3 elements better represent wrinkle patterns than do QUAD3 elements Baseline, ten-inch elements are small enough to accurately represent sail shape, and baseline TRIA3 mesh requires a reasonable computation time of 8 min. 21 sec. In the test/analysis correlation by using Static shape optimization method for Q4 sail, ten parameters were chosen and varied during optimization. 300 sail models were created with random parameters. A response surfaces for each targets which were created based on the varied parameters. Parameters were optimized based on response surface. Deflection shape comparison for 0 and 22.5 degrees yielded a 4.3% and 2.1% error respectively. For the system dynamic study testing was done on the booms without the sails attached. The nominal boom properties produced a good correlation to test data the frequencies were within 10%. Boom dominated analysis frequencies and modes compared well with the test results.

  5. Spatial Autocorrelation Approaches to Testing Residuals from Least Squares Regression

    PubMed Central

    Chen, Yanguang

    2016-01-01

    In geo-statistics, the Durbin-Watson test is frequently employed to detect the presence of residual serial correlation from least squares regression analyses. However, the Durbin-Watson statistic is only suitable for ordered time or spatial series. If the variables comprise cross-sectional data coming from spatial random sampling, the test will be ineffectual because the value of Durbin-Watson’s statistic depends on the sequence of data points. This paper develops two new statistics for testing serial correlation of residuals from least squares regression based on spatial samples. By analogy with the new form of Moran’s index, an autocorrelation coefficient is defined with a standardized residual vector and a normalized spatial weight matrix. Then by analogy with the Durbin-Watson statistic, two types of new serial correlation indices are constructed. As a case study, the two newly presented statistics are applied to a spatial sample of 29 China’s regions. These results show that the new spatial autocorrelation models can be used to test the serial correlation of residuals from regression analysis. In practice, the new statistics can make up for the deficiencies of the Durbin-Watson test. PMID:26800271

  6. Individual Differences in Behavioral and Electrophysiological Measures of Binaural Processing Across the Adult Life Span.

    PubMed

    Roup, Christina M; Leigh, Elizabeth D

    2015-06-01

    The purpose of the present study was to examine individual differences in binaural processing across the adult life span. Sixty listeners (aged 23-80 years) with symmetrical hearing were tested. Binaural behavioral processing was measured by the Words-in-Noise Test, the 500-Hz masking level difference, and the Dichotic Digit Test. Electrophysiologic responses were assessed by the auditory middle latency response binaural interaction component. No correlations among binaural measures were found. Age accounted for the greatest amount of variability in speech-in-noise performance. Age was significantly correlated with the Words-in-Noise Test binaural advantage and dichotic ear advantage. Partial correlations, however, revealed that this was an effect of hearing status rather than age per se. Inspection of individual results revealed that 20% of listeners demonstrated reduced binaural performance for at least 2 of the binaural measures. The lack of significant correlations among variables suggests that each is an important measurement of binaural abilities. For some listeners, binaural processing was abnormal, reflecting a binaural processing deficit not identified by monaural audiologic tests. The inclusion of a binaural test battery in the audiologic evaluation is supported given that these listeners may benefit from alternative forms of audiologic rehabilitation.

  7. Differences in and correlations between cognitive abilities and brain volumes in healthy control, mild cognitive impairment, and Alzheimer disease groups.

    PubMed

    Chung, Soon-Cheol; Choi, Mi-Hyun; Kim, Hyung-Sik; Lee, Jung-Chul; Park, Sung-Jun; Jeong, Ul-Ho; Baek, Ji-Hye; Gim, Seon-Young; Choi, Young Chil; Lee, Beob-Yi; Lim, Dae-Woon; Kim, Boseong

    2016-05-01

    The purpose of this study is to investigate differences in and correlations between cognitive abilities and brain volumes in healthy control (HC), mild cognitive impairment (MCI), and Alzheimer's disease (AD) groups. The Korean Version of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD-K), which is used to diagnose AD, was used to measure the cognitive abilities of the study subjects, and the volumes of typical brain components related to AD diagnosis-cerebrospinal fluid (CSF), gray matter (GM), and white matter (WM)-were acquired. Of the CERAD-K subtests, the Boston Naming Test distinguished significantly among the HC, MCI, and AD groups. GM and WM volumes differed significantly among the three groups. There was a significant positive correlation between Boston Naming Test scores and GM and WM volumes. In conclusion, the Boston Naming Test and GM and WM brain volumes differentiated the three tested groups accurately, and there were strong correlations between Boston Naming Test scores and GM and WM volumes. These results will help to establish a test method that differentiates the three groups accurately and is economically feasible. © 2016 Wiley Periodicals, Inc.

  8. Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

    NASA Technical Reports Server (NTRS)

    Przekop, Adam; Jegley, Dawn C.; Rouse, Marshall; Lovejoy, Andrew E.

    2016-01-01

    This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

  9. Properties of permutation-based gene tests and controlling type 1 error using a summary statistic based gene test

    PubMed Central

    2013-01-01

    Background The advent of genome-wide association studies has led to many novel disease-SNP associations, opening the door to focused study on their biological underpinnings. Because of the importance of analyzing these associations, numerous statistical methods have been devoted to them. However, fewer methods have attempted to associate entire genes or genomic regions with outcomes, which is potentially more useful knowledge from a biological perspective and those methods currently implemented are often permutation-based. Results One property of some permutation-based tests is that their power varies as a function of whether significant markers are in regions of linkage disequilibrium (LD) or not, which we show from a theoretical perspective. We therefore develop two methods for quantifying the degree of association between a genomic region and outcome, both of whose power does not vary as a function of LD structure. One method uses dimension reduction to “filter” redundant information when significant LD exists in the region, while the other, called the summary-statistic test, controls for LD by scaling marker Z-statistics using knowledge of the correlation matrix of markers. An advantage of this latter test is that it does not require the original data, but only their Z-statistics from univariate regressions and an estimate of the correlation structure of markers, and we show how to modify the test to protect the type 1 error rate when the correlation structure of markers is misspecified. We apply these methods to sequence data of oral cleft and compare our results to previously proposed gene tests, in particular permutation-based ones. We evaluate the versatility of the modification of the summary-statistic test since the specification of correlation structure between markers can be inaccurate. Conclusion We find a significant association in the sequence data between the 8q24 region and oral cleft using our dimension reduction approach and a borderline significant association using the summary-statistic based approach. We also implement the summary-statistic test using Z-statistics from an already-published GWAS of Chronic Obstructive Pulmonary Disorder (COPD) and correlation structure obtained from HapMap. We experiment with the modification of this test because the correlation structure is assumed imperfectly known. PMID:24199751

  10. Older drivers: On-road and off-road test results.

    PubMed

    Selander, Helena; Lee, Hoe C; Johansson, Kurt; Falkmer, Torbjörn

    2011-07-01

    Eighty-five volunteer drivers, 65-85 years old, without cognitive impairments impacting on their driving were examined, in order to investigate driving errors characteristic for older drivers. In addition, any relationships between cognitive off-road and on-road tests results, the latter being the gold standard, were identified. Performance measurements included Trail Making Test (TMT), Nordic Stroke Driver Screening Assessment (NorSDSA), Useful Field of View (UFOV), self-rating driving performance and the two on-road protocols P-Drive and ROA. Some of the older drivers displayed questionable driving behaviour. In total, 21% of the participants failed the on-road assessment. Some of the specific errors were more serious than others. The most common driving errors embraced speed; exceeding the speed limit or not controlling the speed. Correlations with the P-Drive protocol were established for NorSDSA total score (weak), UFOV subtest 2 (weak), and UFOV subtest 3 (moderate). Correlations with the ROA protocol were established for UFOV subtest 2 (weak) and UFOV subtest 3 (weak). P-Drive and self ratings correlated weakly, whereas no correlation between self ratings and the ROA protocol was found. The results suggest that specific problems or errors seen in an older person's driving can actually be "normal driving behaviours". Copyright © 2011 Elsevier Ltd. All rights reserved.

  11. ωB97X-V: A 10-parameter, range-separated hybrid, generalized gradient approximation density functional with nonlocal correlation, designed by a survival-of-the-fittest strategy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mardirossian, Narbe; Head-Gordon, Martin

    2013-12-18

    A 10-parameter, range-separated hybrid (RSH), generalized gradient approximation (GGA) density functional with nonlocal correlation (VV10) is presented in this paper. Instead of truncating the B97-type power series inhomogeneity correction factors (ICF) for the exchange, same-spin correlation, and opposite-spin correlation functionals uniformly, all 16 383 combinations of the linear parameters up to fourth order (m = 4) are considered. These functionals are individually fit to a training set and the resulting parameters are validated on a primary test set in order to identify the 3 optimal ICF expansions. Through this procedure, it is discovered that the functional that performs best onmore » the training and primary test sets has 7 linear parameters, with 3 additional nonlinear parameters from range-separation and nonlocal correlation. The resulting density functional, ωB97X-V, is further assessed on a secondary test set, the parallel-displaced coronene dimer, as well as several geometry datasets. Finally and furthermore, the basis set dependence and integration grid sensitivity of ωB97X-V are analyzed and documented in order to facilitate the use of the functional.« less

  12. Meta-Analysis of Correlations Revisited: Attempted Replication and Extension of Field's (2001) Simulation Studies

    ERIC Educational Resources Information Center

    Hafdahl, Adam R.; Williams, Michelle A.

    2009-01-01

    In 2 Monte Carlo studies of fixed- and random-effects meta-analysis for correlations, A. P. Field (2001) ostensibly evaluated Hedges-Olkin-Vevea Fisher-[zeta] and Schmidt-Hunter Pearson-r estimators and tests in 120 conditions. Some authors have cited those results as evidence not to meta-analyze Fisher-[zeta] correlations, especially with…

  13. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    PubMed

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  14. Correlations among ocular surface temperature difference value, the tear meniscus height, Schirmer's test and fluorescein tear film break up time.

    PubMed

    Su, Tai Yuan; Ho, Wei Ting; Lu, Chien Yi; Chang, Shu Wen; Chiang, Huihua Kenny

    2015-04-01

    To report the use of a thermographer for measuring ocular surface temperature, and to evaluate the correlation among the obtained temperature difference values (TDVs) and dry eye parameters (tear meniscus height (TMH); Schirmer's test results; fluorescent tear breakup time (FTBUT)). Forty-three participants (age 40.2±14.7 years; range 21-67 years) from Far Eastern Memorial Hospital, Taiwan were recruited for the study. The surface temperature was measured at the centre of the ocular surface for 4 s after blinking. TDV was defined as the change in corneal surface temperature relative to that of the preceding eye opening, where TDV01, TDV02, TDV03, and TDV04 represent the values obtained 1, 2, 3, and 4 s after blinking, respectively. Anterior segment optical coherence tomography (AS-OCT) was employed to measure the lower TMH. Schirmer's test with topical anaesthetic was conducted to measure the basal tear secretion. The FTBUT was recorded using a digital camera. TDV measurement exhibited high reliability (intraclass correlation coefficient=0.91). TDV03 exhibited the highest significance and strongest positive correlation with the TMH (r=0.52, p=0.0003) and Schirmer's test value (r=0.39, p=0.008), whereas the TDV03-FTBUT correlation was non-significant. Age correlated negatively and significantly with the TDV (r= -0.35, p=0.021), TMH (r= -0.33, p=0.031), and Schirmer's test value (r= -0.31, p=0.044). TDV03 remained significantly correlated with the TMH and Schirmer's test value after adjustment for age. The thermographer was effective in capturing temperature changes in the ocular surface. The temperature difference 3 s after blinking appears to be correlated with lower TMH and Schirmer test values. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Convective Heat Transfer Scaling of Ignition Delay and Burning Rate with Heat Flux and Stretch Rate in the Equivalent Low Stretch Apparatus

    NASA Technical Reports Server (NTRS)

    Olson, Sandra

    2011-01-01

    To better evaluate the buoyant contributions to the convective cooling (or heating) inherent in normal-gravity material flammability test methods, we derive a convective heat transfer correlation that can be used to account for the forced convective stretch effects on the net radiant heat flux for both ignition delay time and burning rate. The Equivalent Low Stretch Apparatus (ELSA) uses an inverted cone heater to minimize buoyant effects while at the same time providing a forced stagnation flow on the sample, which ignites and burns as a ceiling fire. Ignition delay and burning rate data is correlated with incident heat flux and convective heat transfer and compared to results from other test methods and fuel geometries using similarity to determine the equivalent stretch rates and thus convective cooling (or heating) rates for those geometries. With this correlation methodology, buoyant effects inherent in normal gravity material flammability test methods can be estimated, to better apply the test results to low stretch environments relevant to spacecraft material selection.

  16. PISA Trends, Social Changes, and Education Reforms

    ERIC Educational Resources Information Center

    Aloisi, Cesare; Tymms, Peter

    2017-01-01

    The stability of educational test results from the Programme for International Student Assessment (PISA) over 15 years was examined, and the influence of demographics and social capital was assessed, as was the impact of educational reforms. The test results were remarkably stable, with correlations up to 0.99 for country-level results over 2…

  17. The correlation between pulsatile intracranial pressure and indices of intracranial pressure-volume reserve capacity: results from ventricular infusion testing.

    PubMed

    Eide, Per Kristian

    2016-12-01

    OBJECTIVE The objective of this study was to examine how pulsatile and static intracranial pressure (ICP) scores correlate with indices of intracranial pressure-volume reserve capacity, i.e., intracranial elastance (ICE) and intracranial compliance (ICC), as determined during ventricular infusion testing. METHODS All patients undergoing ventricular infusion testing and overnight ICP monitoring during the 6-year period from 2007 to 2012 were included in the study. Clinical data were retrieved from a quality registry, and the ventricular infusion pressure data and ICP scores were retrieved from a pressure database. The ICE and ICC (= 1/ICE) were computed during the infusion phase of the infusion test. RESULTS During the period from 2007 to 2012, 82 patients with possible treatment-dependent hydrocephalus underwent ventricular infusion testing within the department of neurosurgery. The infusion tests revealed a highly significant positive correlation between ICE and the pulsatile ICP scores mean wave amplitude (MWA) and rise-time coefficient (RTC), and the static ICP score mean ICP. The ICE was negatively associated with linear measures of ventricular size. The overnight ICP recordings revealed significantly increased MWA (> 4 mm Hg) and RTC (> 20 mm Hg/sec) values in patients with impaired ICC (< 0.5 ml/mm Hg). CONCLUSIONS In this study cohort, there was a significant positive correlation between pulsatile ICP and ICE measured during ventricular infusion testing. In patients with impaired ICC during infusion testing (ICC < 0.5 ml/mm Hg), overnight ICP recordings showed increased pulsatile ICP (MWA > 4 mm Hg, RTC > 20 mm Hg/sec), but not increased mean ICP (< 10-15 mm Hg). The present data support the assumption that pulsatile ICP (MWA and RTC) may serve as substitute markers of pressure-volume reserve capacity, i.e., ICE and ICC.

  18. Comparison of the Spectral-Temporally Modulated Ripple Test With the Arizona Biomedical Institute Sentence Test in Cochlear Implant Users.

    PubMed

    Lawler, Marshall; Yu, Jeffrey; Aronoff, Justin M

    Although speech perception is the gold standard for measuring cochlear implant (CI) users' performance, speech perception tests often require extensive adaptation to obtain accurate results, particularly after large changes in maps. Spectral ripple tests, which measure spectral resolution, are an alternate measure that has been shown to correlate with speech perception. A modified spectral ripple test, the spectral-temporally modulated ripple test (SMRT) has recently been developed, and the objective of this study was to compare speech perception and performance on the SMRT for a heterogeneous population of unilateral CI users, bilateral CI users, and bimodal users. Twenty-five CI users (eight using unilateral CIs, nine using bilateral CIs, and eight using a CI and a hearing aid) were tested on the Arizona Biomedical Institute Sentence Test (AzBio) with a +8 dB signal to noise ratio, and on the SMRT. All participants were tested with their clinical programs. There was a significant correlation between SMRT and AzBio performance. After a practice block, an improvement of one ripple per octave for SMRT corresponded to an improvement of 12.1% for AzBio. Additionally, there was no significant difference in slope or intercept between any of the CI populations. The results indicate that performance on the SMRT correlates with speech recognition in noise when measured across unilateral, bilateral, and bimodal CI populations. These results suggest that SMRT scores are strongly associated with speech recognition in noise ability in experienced CI users. Further studies should focus on increasing both the size and diversity of the tested participants, and on determining whether the SMRT technique can be used for early predictions of long-term speech scores, or for evaluating differences among different stimulation strategies or parameter settings.

  19. Correaltion of full-scale drag predictions with flight measurements on the C-141A aircraft. Phase 2: Wind tunnel test, analysis, and prediction techniques. Volume 1: Drag predictions, wind tunnel data analysis and correlation

    NASA Technical Reports Server (NTRS)

    Macwilkinson, D. G.; Blackerby, W. T.; Paterson, J. H.

    1974-01-01

    The degree of cruise drag correlation on the C-141A aircraft is determined between predictions based on wind tunnel test data, and flight test results. An analysis of wind tunnel tests on a 0.0275 scale model at Reynolds number up to 3.05 x 1 million/MAC is reported. Model support interference corrections are evaluated through a series of tests, and fully corrected model data are analyzed to provide details on model component interference factors. It is shown that predicted minimum profile drag for the complete configuration agrees within 0.75% of flight test data, using a wind tunnel extrapolation method based on flat plate skin friction and component shape factors. An alternative method of extrapolation, based on computed profile drag from a subsonic viscous theory, results in a prediction four percent lower than flight test data.

  20. Occupant Responses in a Full-Scale Crash Test of the Sikorsky ACAP Helicopter

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Fasanella, Edwin L.; Boitnott, Richard L.; McEntire, Joseph; Lewis, Alan

    2002-01-01

    A full-scale crash test of the Sikorsky Advanced Composite Airframe Program (ACAP) helicopter was performed in 1999 to generate experimental data for correlation with a crash simulation developed using an explicit nonlinear, transient dynamic finite element code. The airframe was the residual flight test hardware from the ACAP program. For the test, the aircraft was outfitted with two crew and two troop seats, and four anthropomorphic test dummies. While the results of the impact test and crash simulation have been documented fairly extensively in the literature, the focus of this paper is to present the detailed occupant response data obtained from the crash test and to correlate the results with injury prediction models. These injury models include the Dynamic Response Index (DRI), the Head Injury Criteria (HIC), the spinal load requirement defined in FAR Part 27.562(c), and a comparison of the duration and magnitude of the occupant vertical acceleration responses with the Eiband whole-body acceleration tolerance curve.

  1. High HIV Prevalence, Suboptimal HIV Testing, and Low Knowledge of HIV-Positive Serostatus Among Injection Drug Users in St. Petersburg, Russia

    PubMed Central

    Toussova, Olga V.; Verevochkin, Sergei V.; Barbour, Russell; Heimer, Robert; Kozlov, Andrei P.

    2011-01-01

    The purpose of this analysis was to estimate human immunodeficiency virus (HIV) prevalence and testing patterns among injection drug users (IDUs) in St. Petersburg, Russia. HIV prevalence among 387 IDUs in the sample was 50%. Correlates of HIV-positive serostatus included unemployment, recent unsafe injections, and history/current sexually transmitted infection. Seventy-six percent had been HIV tested, but only 22% of those who did not report HIV-positive serostatus had been tested in the past 12 months and received their test result. Correlates of this measure included recent doctor visit and having been in prison or jail among men. Among the 193 HIV-infected participants, 36% were aware of their HIV-positive serostatus. HIV prevalence is high and continuing to increase in this population. Adequate coverage of HIV testing has not been achieved, resulting in poor knowledge of positive serostatus. Efforts are needed to better understand motivating and deterring factors for HIV testing in this setting. PMID:18843531

  2. Predicting occupational personality test scores.

    PubMed

    Furnham, A; Drakeley, R

    2000-01-01

    The relationship between students' actual test scores and their self-estimated scores on the Hogan Personality Inventory (HPI; R. Hogan & J. Hogan, 1992), an omnibus personality questionnaire, was examined. Despite being given descriptive statistics and explanations of each of the dimensions measured, the students tended to overestimate their scores; yet all correlations between actual and estimated scores were positive and significant. Correlations between self-estimates and actual test scores were highest for sociability, ambition, and adjustment (r = .62 to r = .67). The results are discussed in terms of employers' use and abuse of personality assessment for job recruitment.

  3. Joint Live Fire (JLF) Final Report for Instrumentation for Local Accelerative Loading

    DTIC Science & Technology

    2016-07-22

    Comparison with Pretest Prediction ................................................................................... 60 d. Lessons Learned...test designs and results prior to full-scale testing. Correlating simulation to test data can aid in increasing confidence in the models to further...test and test-to-simulation with the current instrumentation used during testing. Recent advances in accelerometer design must be evaluated and

  4. Sleep quality and communication aspects in children.

    PubMed

    de Castro Corrêa, Camila; José, Maria Renata; Andrade, Eduardo Carvalho; Feniman, Mariza Ribeiro; Fukushiro, Ana Paula; Berretin-Felix, Giédre; Maximino, Luciana Paula

    2017-09-01

    To correlate quality of life of children in terms of sleep, with their oral language skills, auditory processing and orofacial myofunctional aspects. Nineteen children (12 males and seven females, in the mean age 9.26) undergoing otorhinolaryngological and speech evaluations participated in this study. The OSA-18 questionnaire was applied, followed by verbal and nonverbal sequential memory tests, dichotic digit test, nonverbal dichotic test and Sustained Auditory Attention Ability Test, related to auditory processing. The Phonological Awareness Profile test, Rapid Automatized Naming and Phonological Working Memory were used for assessment of the phonological processing. Language was assessed by the ABFW Child Language Test, analyzing the phonological and lexical levels. Orofacial myofunctional aspects were evaluated through the MBGR Protocol. Statistical tests used: the Mann-Whitney Test, Fisher's exact test and Spearman Correlation. Relating the performance of children in all evaluations to the results obtained in the OSA-18, there was a statistically significant correlation in the phonological working memory for backward digits (p = 0.04); as well as in the breathing item (p = 0.03), posture of the mandible (p = 0.03) and mobility of lips (p = 0.04). A correlation was seen between the sleep quality of life and the skills related to the phonological processing, specifically in the phonological working memory in backward digits, and related to orofacial myofunctional aspects. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Correlation of spacecraft thermal mathematical models to reference data

    NASA Astrophysics Data System (ADS)

    Torralbo, Ignacio; Perez-Grande, Isabel; Sanz-Andres, Angel; Piqueras, Javier

    2018-03-01

    Model-to-test correlation is a frequent problem in spacecraft-thermal control design. The idea is to determine the values of the parameters of the thermal mathematical model (TMM) that allows reaching a good fit between the TMM results and test data, in order to reduce the uncertainty of the mathematical model. Quite often, this task is performed manually, mainly because a good engineering knowledge and experience is needed to reach a successful compromise, but the use of a mathematical tool could facilitate this work. The correlation process can be considered as the minimization of the error of the model results with regard to the reference data. In this paper, a simple method is presented suitable to solve the TMM-to-test correlation problem, using Jacobian matrix formulation and Moore-Penrose pseudo-inverse, generalized to include several load cases. Aside, in simple cases, this method also allows for analytical solutions to be obtained, which helps to analyze some problems that appear when the Jacobian matrix is singular. To show the implementation of the method, two problems have been considered, one more academic, and the other one the TMM of an electronic box of PHI instrument of ESA Solar Orbiter mission, to be flown in 2019. The use of singular value decomposition of the Jacobian matrix to analyze and reduce these models is also shown. The error in parameter space is used to assess the quality of the correlation results in both models.

  6. bc-GenExMiner 3.0: new mining module computes breast cancer gene expression correlation analyses.

    PubMed

    Jézéquel, Pascal; Frénel, Jean-Sébastien; Campion, Loïc; Guérin-Charbonnel, Catherine; Gouraud, Wilfried; Ricolleau, Gabriel; Campone, Mario

    2013-01-01

    We recently developed a user-friendly web-based application called bc-GenExMiner (http://bcgenex.centregauducheau.fr), which offered the possibility to evaluate prognostic informativity of genes in breast cancer by means of a 'prognostic module'. In this study, we develop a new module called 'correlation module', which includes three kinds of gene expression correlation analyses. The first one computes correlation coefficient between 2 or more (up to 10) chosen genes. The second one produces two lists of genes that are most correlated (positively and negatively) to a 'tested' gene. A gene ontology (GO) mining function is also proposed to explore GO 'biological process', 'molecular function' and 'cellular component' terms enrichment for the output lists of most correlated genes. The third one explores gene expression correlation between the 15 telomeric and 15 centromeric genes surrounding a 'tested' gene. These correlation analyses can be performed in different groups of patients: all patients (without any subtyping), in molecular subtypes (basal-like, HER2+, luminal A and luminal B) and according to oestrogen receptor status. Validation tests based on published data showed that these automatized analyses lead to results consistent with studies' conclusions. In brief, this new module has been developed to help basic researchers explore molecular mechanisms of breast cancer. DATABASE URL: http://bcgenex.centregauducheau.fr

  7. The Relationship between Central Auditory Processing, Language, and Cognition in Children Being Evaluated for Central Auditory Processing Disorder.

    PubMed

    Brenneman, Lauren; Cash, Elizabeth; Chermak, Gail D; Guenette, Linda; Masters, Gay; Musiek, Frank E; Brown, Mallory; Ceruti, Julianne; Fitzegerald, Krista; Geissler, Kristin; Gonzalez, Jennifer; Weihing, Jeffrey

    2017-09-01

    Pediatric central auditory processing disorder (CAPD) is frequently comorbid with other childhood disorders. However, few studies have examined the relationship between commonly used CAPD, language, and cognition tests within the same sample. The present study examined the relationship between diagnostic CAPD tests and "gold standard" measures of language and cognitive ability, the Clinical Evaluation of Language Fundamentals (CELF) and the Wechsler Intelligence Scale for Children (WISC). A retrospective study. Twenty-seven patients referred for CAPD testing who scored average or better on the CELF and low average or better on the WISC were initially included. Seven children who scored below the CELF and/or WISC inclusion criteria were then added to the dataset for a second analysis, yielding a sample size of 34. Participants were administered a CAPD battery that included at least the following three CAPD tests: Frequency Patterns (FP), Dichotic Digits (DD), and Competing Sentences (CS). In addition, they were administered the CELF and WISC. Relationships between scores on CAPD, language (CELF), and cognition (WISC) tests were examined using correlation analysis. DD and FP showed significant correlations with Full Scale Intelligence Quotient, and the DD left ear and the DD interaural difference measures both showed significant correlations with working memory. However, ∼80% or more of the variance in these CAPD tests was unexplained by language and cognition measures. Language and cognition measures were more strongly correlated with each other than were the CAPD tests with any CELF or WISC scale. Additional correlations with the CAPD tests were revealed when patients who scored in the mild-moderate deficit range on the CELF and/or in the borderline low intellectual functioning range on the WISC were included in the analysis. While both the DD and FP tests showed significant correlations with one or more cognition measures, the majority of the variance in these CAPD measures went unexplained by cognition. Unlike DD and FP, the CS test was not correlated with cognition. Additionally, language measures were not significantly correlated with any of the CAPD tests. Our findings emphasize that the outcomes and interpretation of results vary as a function of the subject inclusion criteria that are applied for the CELF and WISC. Including participants with poorer cognition and/or language scores increased the number of significant correlations observed. For this reason, it is important that studies investigating the relationship between CAPD and other domains or disorders report the specific inclusion criteria used for all tests. American Academy of Audiology

  8. The Reliability, Validity, and Normative Data of Interpupillary Distance and Pupil Diameter Using Eye-Tracking Technology

    PubMed Central

    Murray, Nicholas P.; Hunfalvay, Melissa; Bolte, Takumi

    2017-01-01

    Purpose The purpose of this study was to determine the reliability of interpupillary distance (IPD) and pupil diameter (PD) measures using an infrared eye tracker and central point stimuli. Validity of the test compared to known clinical tools was determined, and normative data was established against which individuals can measure themselves. Methods Participants (416) across various demographics were examined for normative data. Of these, 50 were examined for reliability and validity. Validity for IPD measured the test (RightEye IPD/PD) against the PL850 Pupilometer and the Essilor Digital CRP. For PD, the test was measured against the Rosenbaum Pocket Vision Screener (RPVS). Reliability was analyzed with intraclass correlation coefficients (ICC) between trials with Cronbach's alpha (CA) and the standard error of measurement for each ICC. Convergent validity was investigated by calculating the bivariate correlation coefficient. Results Reliability results were strong (CA > 0.7) for all measures. High positive significant correlations were found between the RightEye IPD test and the PL850 Pupilometer (P < 0.001) and Essilor Digital CRP (P < 0.001) and for the RightEye PD test and the RPVS (P < 0.001). Conclusions Using infrared eye tracking and the RightEye IPD/PD test stimuli, reliable and accurate measures of IPD and PD were found. Results from normative data showed an adequate comparison for people with normal vision development. Translational Relevance Results revealed a central point of fixation may remove variability in examining PD reliably using infrared eye tracking when consistent environmental and experimental procedures are conducted. PMID:28685104

  9. Still under the microscope: can a surgical aptitude test predict otolaryngology resident performance?

    PubMed

    Moore, Eric J; Price, Daniel L; Van Abel, Kathryn M; Carlson, Matthew L

    2015-02-01

    Application to otolaryngology-head and neck surgery residency is highly competitive, and the interview process strives to select qualified applicants with a high aptitude for the specialty. Commonly employed criteria for applicant selection have failed to show correlation with proficiency during residency training. We evaluate the correlation between the results of a surgical aptitude test administered to otolaryngology resident applicants and their performance during residency. Retrospective study at an academic otolaryngology-head and neck surgery residency program. Between 2007 and 2013, 224 resident applicants participated in a previously described surgical aptitude test administered at a microvascular surgical station. The composite score and attitudinal scores for 24 consecutive residents who matched at our institution were recorded, and their residency performance was analyzed by faculty survey on a five-point scale. The composite and attitudinal scores were analyzed for correlation with residency performance score by regression analysis. Twenty-four residents were evaluated for overall quality as a clinician by eight faculty members who were blinded to the results of surgical aptitude testing. The results of these surveys showed good inter-rater reliability. Both the overall aptitude test scores and the subset attitudinal score showed reliability in predicting performance during residency training. The goal of the residency selection process is to evaluate the candidate's potential for success in residency and beyond. The results of this study suggest that a simple-to-administer clinical skills test may have predictive value for success in residency and clinician quality. 4. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  10. The Biology of Ageing in Leaves.

    ERIC Educational Resources Information Center

    Gill, John; And Others

    1988-01-01

    Describes laboratory procedures for observing the progressive change deciduous leaves undergo prior to abscission. Outlines the starch test, sugar test, extraction and chromatography of pigments, and experimental results. States that obtained results enable the events of leaf senescence to be correlated with the carbohydrate economy of a tree in…

  11. The Kmif (Kveim-induced macrophage migration inhibition factor) test in sarcoidosis

    PubMed Central

    Williams, W. Jones; Pioli, E.; Jones, D. J.; Dighero, M.

    1972-01-01

    Circulating lymphocytes from 30 patients with sarcoidosis when stimulated in vitro with Kveim-induced macrophage migration factor, the Kmif test, produced a guinea-pig macrophage migration inhibition factor in 21 of 30 cases (70%). In those patients not on steroids the results showed a good correlation with the cutaneous Kveim test. One positive test was found in 16 normal subjects. Our results suggest that the Kmif test may prove a useful rapid alternative to the Kveim test. PMID:4675181

  12. Thromboelastography in Dogs with Chronic Hepatopathies.

    PubMed

    Fry, W; Lester, C; Etedali, N M; Shaw, S; DeLaforcade, A; Webster, C R L

    2017-03-01

    The coagulation status of dogs with liver disease is difficult to predict using conventional coagulation testing. To evaluate thromboelastography (TEG) results and associations with conventional coagulation results and indicators of disease severity and prognosis in dogs with chronic hepatopathies (CH). Twenty-one client-owned dogs. Dogs with CH were prospectively (10 dogs) and retrospectively (11 dogs) enrolled from 2008 to 2014. Kaolin-activated TEG was performed and compared with reference intervals by t-tests or Mann-Whitney tests. Correlation coefficients for TEG results and conventional coagulation and clinicopathologic results were determined. Significance was set at P < .05. Dogs with CH had significant increases in R (5.30 min vs 4.33 min), K (3.77 min vs 2.11 min), and LY30 (4.77% vs 0.68%) and decreased angles (55.3° vs 62.4°). G value defined 9 of 21, 7 of 21, and 5 of 21 dogs as normocoagulable, hypercoagulable, and hypocoagulable, respectively. G and MA were correlated with fibrinogen (r = 0.68, 0.83), prothrombin time (PT; r = -0.51, -0.53), and activated partial thromboplastin time (aPTT; r = -0.50, -0.50). K was correlated with PT (r = 0.75) and protein C activity (r = -0.92). Angle was correlated with aPTT (r = -0.63). Clinical score was correlated with PT (r = 0.60), MA (r = -0.53), and R (r = -0.47). Dogs with hyperfibrinolysis (LY30 > 3.04%; 5 of 21) had significantly higher serum transaminase activities. Dogs with portal hypertension had significantly lower G, MA, and angle and prolonged, K, R, and PT. Dogs with CH have variable TEG results. Negative prognostic indicators in CH correlate with hypocoagulable parameters on TEG. Hyperfibrinolysis in dogs with CH is associated with high disease activity. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  13. Relationships between postural orientation and self reported function, hop performance and muscle power in subjects with anterior cruciate ligament injury.

    PubMed

    Trulsson, Anna; Roos, Ewa M; Ageberg, Eva; Garwicz, Martin

    2010-07-01

    Injury to the anterior cruciate ligament (ACL) is associated not only with knee instability and impaired neuromuscular control, but also with altered postural orientation manifested as observable "substitution patterns". However, tests currently used to evaluate knee function in subjects with ACL injury are not designed to assess postural orientation. Therefore, we are in the process of developing an observational test set that measures postural orientation in terms of the ability to stabilize body segments in relation to each other and to the environment. The aim of the present study was to characterise correlations between this novel test set, called the Test for Substitution Patterns (TSP) and commonly used tests of knee function. In a blinded set-up, 53 subjects (mean age 30 years, range 20-39, with 2-5 years since ACL injury) were assessed using the TSP, the Knee Injury and Osteoarthritis Outcome Score subscale sport/recreation (KOOS sport/rec), 3 hop tests and 3 muscle power tests. Correlations between the scores of the TSP and the other tests were determined. Moderate correlations were found between TSP scores and KOOS sport/rec (rs = -0.43; p = 0.001) and between TSP scores and hop test results (rs = -0.40 to -0.46; p < or = 0.003), indicating that altered postural orientation was associated with worse self-reported KOOS sport/rec function and worse hop performance. No significant correlations were found between TSP scores and muscle power results. Subjects had higher TSP scores on their injured side than on their uninjured side (median 4 and 1 points; interquartile range 2-6 and 0-1.5, respectively; p < 0.0001). We conclude that the Test for Substitution Patterns is of relevance to the patient and measures a specific aspect of neuromuscular control not quantified by the other tests investigated. We suggest that the TSP may be a valuable complement in the assessment of neuromuscular control in the rehabilitation of subjects with ACL injury.

  14. Correlations among assays of porcine semen quality following cryopreservation.

    PubMed

    Hammitt, D G; Martin, P A

    1989-09-01

    Correlations between in vitro tests of semen quality, used to predict the in vivo fertilizing potential of sperm, indicate that the tests may substitute for each other in predicting fertilizing potential. Lack of correlation between tests suggest that both tests should be used to estimate the fertilizing potential. The purpose of this study was to establish correlations between several in vitro tests of porcine semen quality following freezing. Tests of motility with and without caffeine, spermatozoa with normal apical ridges, sephadex filtration with and without caffeine and acrosin activity were all correlated with each other. Correlations among these tests ranged from 0.45 to 0.83 (P<0.05). Assays for glutamic oxalacetic transaninase (GOT) were not consistently correlated with other tests. None of these tests of semen quality were correlated with the sperm penetration assay except for the test of motility without caffeine, which was correlated with the number of penetrations per hamster oocyte (r = 0.71, P<0.05).

  15. Radon Risk Perception and Testing: Sociodemographic Correlates.

    ERIC Educational Resources Information Center

    Halpern, Michael T.; Warner, Kenneth E.

    1994-01-01

    Using information from the 1990 National Health Interview Survey, examined beliefs regarding radon and radon-testing activities among different sociodemographic groups. Results suggest relatively superficial knowledge regarding radon, and little testing, within the survey population. Significantly less knowledge was observed among female and…

  16. Correlation Between Ultrasonic Nondestructive Inspection and Wheel Test of 34 Retreaded Tires

    DOT National Transportation Integrated Search

    1979-11-01

    The report covers a test in which 34 retread tires were inspected using reflection ultrasound nondestructive inspection, wheel tested and then subjected to failure analysis by sectioning. The results demonstrate for the first time the ability of ultr...

  17. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients

    PubMed Central

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-01-01

    Abstract Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests. Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed. The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values. Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients. PMID:27311005

  18. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients.

    PubMed

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-06-01

    Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests.Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed.The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values.Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test. There were correlations between TEG parameters and corresponding conventional tests. K values can better predict elevated fibrinogen levels in aged fracture patients.

  19. Pre-clinical validation of a new intra-operative "dual beam Doppler" blood flowmeter in an artificial circuit.

    PubMed

    Cikirikcioglu, Mustafa; Cikirikcioglu, Y Banu; Khabiri, Ebrahim; Djebaili, M Karim; Kalangos, Afksendiyos; Walpoth, Beat H

    2006-01-01

    Intra-operative flow measurement during coronary or peripheral bypass operations is helpful for ruling out technical failures and for prediction of complication and patency rates. Preclinical validation of the flowmeters is required in order to rely on the intra-operatively measured results. The aim of this study is to evaluate a new "dual beam Doppler" blood flowmeter before clinical application and to compare it with the established "transit time flow measure-ment" technique in an artificial circuit. Measurements were performed in an experimental flow model using pig blood and pig arteries. Three different flowmeters were used: Quantix OR (dual beam doppler flowmeter), CardioMed (transit time flowmeter), and Transonic (transit time flowmeter). Three validation tests were performed to assess correlation, precision, and repeatability of devices. (1) Correlation and agreement analysis was performed with various flow amounts (10-350 mL/min) (n = 160). (2) Device reproducibility and measurement stability were tested with a constant flow (flow amount = 300 mL/min) (n = 30). (3) A user accuracy test (intra- and inter-observer variability) was performed by 5 different observers with a constant flow (flow amount = 205 mL/min) (n = 75). Time collected true flow was used as a reference method in all steps and all tests were performed in a blind manner. Results are shown as mean values +/- standard deviations. Pear-son's correlation and Bland-Altman plot analyses were used to compare measurements. The mean flow was 167 +/- 98 mL/min for true flow and 162 +/- 94 mL/min, 165 +/- 94 mL/min, and 166 +/- 100 mL/min for Quantix OR, CardioMed, and Transonic, respectively. Correlation coefficients between Quantix OR, Medi-Stim, Transonic, and time collected true flow were over 0.98 (P = .01). Most of the measured results ( > 90%) were between +/- 1.96 SD agreement limits in Bland and Altman plot analysis. All devices showed good results in the reproducibility test. During the user accuracy test, larger variance changes were observed between intra- and inter-observer results with the dual beam Doppler flowmeter compared to the 2 used transit time flowmeters when used for single sided vessel access without stabilization device (available from the manufacturer). All 3 tested flowmeters showed an excellent correlation to the true flow in an artificial circuit and the accuracy of the tested devices was within agreement limits. Reproducibility of all devices was good and linear. The new dual beam Doppler flow measurement technique compares favorably to the classic transit time method. Clinical use may depend on operator, location, and condition, thus more studies may be required to ensure uniform results using the currently available blood flow measurement devices.

  20. Performance of the cobas Hepatitis B virus (HBV) test using the cobas 4800 system and comparison of HBV DNA quantification ability between the COBAS AmpliPrep/COBAS TaqMan HBV test version 2.0 and cobas HBV test.

    PubMed

    Shin, Kyung-Hwa; Lee, Hyun-Ji; Chang, Chulhun L; Kim, Hyung-Hoi

    2018-04-01

    Hepatitis B virus (HBV) DNA levels are used to predict the response to therapy, determine therapy initiation, monitor resistance to therapy, and establish treatment success. To verify the performance of the cobas HBV test using the cobas 4800 system for HBV DNA quantification and to compare the HBV DNA quantification ability between the cobas HBV test and COBAS AmpliPrep/COBAS TaqMan HBV version 2.0 (CAP/CTM v2.0). The precision, linearity, and limit of detection of the cobas HBV test were evaluated using the 4th World Health Organization International Standard material and plasma samples. Clinical samples that yielded quantitative results using the CAP/CTM v2.0 and cobas HBV tests were subjected to correlational analysis. Three hundred forty-nine samples were subjected to correlational analysis, among which 114 samples showed results above the lower limit of quantification. Comparable results were obtained ([cobas HBV test] = 1.038 × [CAP/CTM v2.0]-0.173, r = 0.914) in 114 samples, which yielded values above the lower limit of quantification. The results for 86.8% of the samples obtained using the cobas HBV test were within 0.5 log 10 IU/mL of the CAP/CTM v2.0 results. The total precision values against the low and high positive controls were 1.4% (mean level: 2.25 log 10 IU/mL) and 3.2% (mean level: 6.23 log 10 IU/mL), respectively. The cobas HBV test demonstrated linearity (1.15-6.75 log 10 IU/mL, y = 0.95 × 6 + 0.17, r 2  = 0.994). The cobas HBV test showed good correlation with CAP/CTM v2.0, and had good precision and an acceptable limit of detection. The cobas HBV test using the cobas 4800 is a reliable method for quantifying HBV DNA levels in the clinical setting. Copyright © 2018. Published by Elsevier B.V.

  1. The Reliability and Validity of the Computerized Double Inclinometer in Measuring Lumbar Mobility

    PubMed Central

    MacDermid, Joy Christine; Arumugam, Vanitha; Vincent, Joshua Israel; Carroll, Krista L

    2014-01-01

    Study Design : Repeated measures reliability/validity study. Objectives : To determine the concurrent validity, test-retest, inter-rater and intra-rater reliability of lumbar flexion and extension measurements using the Tracker M.E. computerized dual inclinometer (CDI) in comparison to the modified-modified Schober (MMS) Summary of Background : Numerous studies have evaluated the reliability and validity of the various methods of measuring spinal motion, but the results are inconsistent. Differences in equipment and techniques make it difficult to correlate results. Methods : Twenty subjects with back pain and twenty without back pain were selected through convenience sampling. Two examiners measured sagittal plane lumbar range of motion for each subject. Two separate tests with the CDI and one test with the MMS were conducted. Each test consisted of three trials. Instrument and examiner order was randomly assigned. Intra-class correlations (ICCs 2, 2 and 2, 2) and Pearson correlation coefficients (r) were used to calculate reliability and concurrent validity respectively. Results : Intra-trial reliability was high to very high for both the CDI (ICCs 0.85 - 0.96) and MMS (ICCs 0.84 - 0.98). However, the reliability was poor to moderate, when the CDI unit had to be repositioned either by the same rate (ICCs 0.16 - 0.59) or a different rater (ICCs 0.45 - 0.52). Inter-rater reliability for the MMS was moderate to high (ICCs 0.75 - 0.82) which bettered the moderate correlation obtained for the CDI (ICCs 0.45 - 0.52). Correlations between the CDI and MMS were poor for flexion (0.32; p<0.05) and poor to moderate (-0.42 - -0.51; p<0.05) for extension measurements. Conclusion : When using the CDI, an average of subsequent tests is required to obtain moderate reliability. The MMS was highly reliable than the CDI. The MMS and the CDI measure lumbar movement on a different metric that are not highly related to each other. PMID:25352928

  2. Morphological correlation between caloric tests and vestibular hydrops in Ménière's disease using intravenous Gd enhanced inner ear MRI.

    PubMed

    Choi, Ji Eun; Kim, Yi-Kyung; Cho, Young Sang; Lee, Kieun; Park, Hyun Woo; Yoon, Sung Hoon; Kim, Hyung-Jin; Chung, Won-Ho

    2017-01-01

    The purpose of this study was to prove the hypothesis that caloric response in Ménière's disease (MD) is reduced by hydropic expansion of the vestibular labyrinth, not by vestibular hypofunction, by evaluating the correlation morphologically using an intravenous Gadolinium (IV-Gd) inner ear MRI. In study I, the prevalence of abnormal video Head Impulse Test (vHIT) results among the patients with definite unilateral MD (n = 24) and vestibular neuritis (VN) (n = 22) were investigated. All patients showed abnormal canal paresis (CP) (> 26%) on caloric tests. The prevalence of abnormal vHIT in patients with abnormal CP was significantly lower in MD patients (12.5%) than that in VN patients (81.8%) (p < 0.001). In study II, morphological correlation between caloric tests and vestibular hydrops level was evaluated in unilateral MD patients (n = 16) who had normal vHIT results. Eleven patients (61%) had abnormal CP. After taking the images of IV-Gd inner ear MRI, the vestibular hydrops ratio (endolymph volume/total lymph volume = %VH) was measured. In addition, the relative vestibular hydrops ratio (%RVH = (%VHaffected ear-%VHunaffected ear) / (%VHaffected ear + %VHunaffected ear)) was calculated. Each ratio (%VH and %RVH) was compared with average peak slow phase velocity (PSPV) and CP, respectively. In the MD patients, %VH of the affected ear correlated significantly with mean PSPV on the same side (rs = -0.569, p = 0.024), while %RVH correlated significantly with CP (rs = 0.602, p = 0.014). In most MD patients (87.5%) compared to VN patients, vHIT results were normal even though the caloric function was reduced. In addition, the reduced caloric function with normal vHIT was related to the severity of the vestibular hydrops measured by the IV-Gd inner ear MRI. These findings concluded that the abnormal caloric tests with normal vHIT in MD indicated severe endolymphatic hydrops rather than vestibular hypofunction.

  3. Modified friction factor correlation for CICC's based on a porous media analogy

    NASA Astrophysics Data System (ADS)

    Lewandowska, Monika; Bagnasco, Maurizio

    2011-09-01

    A modified correlation for the bundle friction factor in CICC's based on a porous media analogy is presented. The correlation is obtained by the analysis of the collected pressure drop data measured for 23 CICC's. The friction factors predicted by the proposed correlation are compared with those resulting from the pressure drop data for two CICC's measured recently using cryogenic helium in the SULTAN test facility at EPFL-CRPP.

  4. White Matter Tract Integrity in Alzheimer's Disease vs. Late Onset Bipolar Disorder and Its Correlation with Systemic Inflammation and Oxidative Stress Biomarkers.

    PubMed

    Besga, Ariadna; Chyzhyk, Darya; Gonzalez-Ortega, Itxaso; Echeveste, Jon; Graña-Lecuona, Marina; Graña, Manuel; Gonzalez-Pinto, Ana

    2017-01-01

    Background: Late Onset Bipolar Disorder (LOBD) is the development of Bipolar Disorder (BD) at an age above 50 years old. It is often difficult to differentiate from other aging dementias, such as Alzheimer's Disease (AD), because they share cognitive and behavioral impairment symptoms. Objectives: We look for WM tract voxel clusters showing significant differences when comparing of AD vs. LOBD, and its correlations with systemic blood plasma biomarkers (inflammatory, neurotrophic factors, and oxidative stress). Materials: A sample of healthy controls (HC) ( n = 19), AD patients ( n = 35), and LOBD patients ( n = 24) was recruited at the Alava University Hospital. Blood plasma samples were obtained at recruitment time and analyzed to extract the inflammatory, oxidative stress, and neurotrophic factors. Several modalities of MRI were acquired for each subject, Methods: Fractional anisotropy (FA) coefficients are obtained from diffusion weighted imaging (DWI). Tract based spatial statistics (TBSS) finds FA skeleton clusters of WM tract voxels showing significant differences for all possible contrasts between HC, AD, and LOBD. An ANOVA F -test over all contrasts is carried out. Results of F -test are used to mask TBSS detected clusters for the AD > LOBD and LOBD > AD contrast to select the image clusters used for correlation analysis. Finally, Pearson's correlation coefficients between FA values at cluster sites and systemic blood plasma biomarker values are computed. Results: The TBSS contrasts with by ANOVA F -test has identified strongly significant clusters in the forceps minor, inferior longitudinal fasciculus, inferior fronto-occipital fasciculus, and cingulum gyrus. The correlation analysis of these tract clusters found strong negative correlation of AD with the nerve growth factor (NGF) and brain derived neurotrophic factor (BDNF) blood biomarkers. Negative correlation of AD and positive correlation of LOBD with inflammation biomarker IL6 was also found. Conclusion: TBSS voxel clusters tract atlas localizations are consistent with greater behavioral impairment and mood disorders in LOBD than in AD. Correlation analysis confirms that neurotrophic factors (i.e., NGF, BDNF) play a great role in AD while are absent in LOBD pathophysiology. Also, correlation results of IL1 and IL6 suggest stronger inflammatory effects in LOBD than in AD.

  5. Correlation of black smoke and nitrogen oxides emissions through field testing of in-use diesel vehicles.

    PubMed

    Lin, Cherng-Yuan; Chen, Lih-Wei; Wang, Li-Ting

    2006-05-01

    Diesel vehicles are one of the major forms of transportation, especially in metropolitan regions. However, air pollution released from diesel vehicles causes serious damage to both human health and the environment, and as a result is of great public concern. Nitrogen oxides and black smoke are two significant emissions from diesel engines. Understanding the correlation between these two emissions is an important step toward developing the technology for an appropriate strategy to control or eliminate them. This study field-tested 185 diesel vehicles at an engine dynamometer station for their black smoke reflectivity and nitrogen oxides concentration to explore the correlation between these two pollutants. The test results revealed that most of the tested diesel vehicles emitted black smoke with low reflectivity and produced low nitrogen oxides concentration. The age of the tested vehicles has a significant influence on the NOx emission. The older the tested vehicles, the higher the NOx concentrations emitted, however, there was no obvious correlation between the age of the tested diesel vehicles and the black smoke reflectivity. In addition, if the make and engine displacement volume of the tested diesel vehicles are not taken into consideration, then the correlation between the black smoke reflectivity and nitrogen oxides emission weakens. However, when the tested vehicles were classified into various groups based on their makes and engine displacement volumes, then the make of a tested vehicle became a dominant factor for both the quantity and the trend of the black smoke reflectivity, as well as the NOx emission. Higher emission indices of black smoke reflectivity and nitrogen oxides were observed if the diesel vehicles were operated at low engine speed and full engine load conditions. Moreover, the larger the displacement volume of the engine of the tested vehicle, the lower the emission indices of both black smoke reflectivity and nitrogen oxides emitted. The emission indices of black smokes reflectivity and nitrogen oxides emission of the tested diesel vehicles were also influenced by the make of the vehicle. It was observed that the emission indices of black smoke reflectivity decreased nearly linearly with the increase of the emission indices of NOx for the tested vehicles belonging to the same group of make and engine displacement volume.

  6. Comparative neurobehavioral study of a polybrominated biphenyl-exposed population in Michigan and a nonexposed group in Wisconsin.

    PubMed Central

    Valciukas, J A; Lilis, R; Wolff, M S; Anderson, H A

    1978-01-01

    An analysis of findings regarding the prevalence and time course of symptoms and the results of neurobehavioral testing among Michigan and Wisconsin dairy farmers, is reported. Reviewed are: (1) differences in the prevalence of neurological symptoms at the time of examination; (2) differences in the incidence and time course of symptoms for the period 1972--1976; (3) differences among populations and subgroups (sex and age) regarding performance test scores; (4) correlations between performance test scores and neurological symptoms; and (5) correlations between serum PBB levels as indicators of exposure and performance tests and neurological symptoms. PMID:209977

  7. Assessment of Mudrock Brittleness with Micro-scratch Testing

    NASA Astrophysics Data System (ADS)

    Hernandez-Uribe, Luis Alberto; Aman, Michael; Espinoza, D. Nicolas

    2017-11-01

    Mechanical properties are essential for understanding natural and induced deformational behavior of geological formations. Brittleness characterizes energy dissipation rate and strain localization at failure. Brittleness has been investigated in hydrocarbon-bearing mudrocks in order to quantify the impact of hydraulic fracturing on the creation of complex fracture networks and surface area for reservoir drainage. Typical well logging correlations associate brittleness with carbonate content or dynamic elastic properties. However, an index of rock brittleness should involve actual rock failure and have a consistent method to quantify it. Here, we present a systematic method to quantify mudrock brittleness based on micro-mechanical measurements from the scratch test. Brittleness is formulated as the ratio of energy associated with brittle failure to the total energy required to perform a scratch. Soda lime glass and polycarbonate are used for comparison to identify failure in brittle and ductile mode and validate the developed method. Scratch testing results on mudrocks indicate that it is possible to use the recorded transverse force to estimate brittleness. Results show that tested samples rank as follows in increasing degree of brittleness: Woodford, Eagle Ford, Marcellus, Mancos, and Vaca Muerta. Eagle Ford samples show mixed ductile/brittle failure characteristics. There appears to be no definite correlation between micro-scratch brittleness and quartz or total carbonate content. Dolomite content shows a stronger correlation with brittleness than any other major mineral group. The scratch brittleness index correlates positively with increasing Young's modulus and decreasing Poisson's ratio, but shows deviations in rocks with distinct porosity and with stress-sensitive brittle/ductile behavior (Eagle Ford). The results of our study demonstrate that the micro-scratch test method can be used to investigate mudrock brittleness. The method is particularly useful for reservoir characterization methods that take advantage of drill cuttings or whenever large samples for triaxial testing or fracture mechanics testing cannot be recovered.

  8. Flammability Indices for Refrigerants

    NASA Astrophysics Data System (ADS)

    Kataoka, Osami

    This paper introduces a new index to classify flammable refrigerants. A question on flammability indices that ASHRAE employs arose from combustion test results of R152a and ammonia. Conventional methods of not only ASHRAE but also ISO and Japanese High-pressure gas safety law to classify the flammability of refrigerants are evaluated to show why these methods conflict with the test results. The key finding of this paper is that the ratio of stoichiometric concentration to LFL concentration (R factor) represents the test results most precisely. In addition, it has excellent correlation with other flammability parameters such as flame speed and pressure rise coefficient. Classification according to this index gives reasonable flammability order of substances including ammonia, R152a and carbon monoxide. Theoretical background why this index gives good correlation is also discussed as well as the insufficient part of this method.

  9. Performance on the Functional Movement Screen™ is related to hop performance, but not to hip and knee strength in collegiate football players

    PubMed Central

    Willigenburg, Nienke; Hewett, Timothy E.

    2016-01-01

    Objective To define the relationship between FMS™ scores and hop performance, hip strength, and knee strength in collegiate football players. Design Cross-sectional cohort. Participants Freshmen of a division I collegiate American football team (n=59). Main Outcome Measures The athletes performed the FMS™, as well as a variety of hop tests, isokinetic knee strength and isometric hip strength tasks. We recorded total FMS™ score, peak strength and hop performance, and we calculated asymmetries between legs on the different tasks. Spearman’s correlation coefficients quantified the relationships these measures, and chi-square analyses compared the number of athletes with asymmetries on the different tasks. Results We observed significant correlations (r=0.38–0.56, p≤0.02) between FMS™ scores and hop distance, but not between FMS™ scores and hip or knee strength (all p≥0.21). The amount of asymmetry on the FMS™ test was significantly correlated to the amount of asymmetry on the timed 6m hop (r=0.44, p<0.01), but not to hip or knee strength asymmetries between limbs (all p≥0.34). Conclusions FMS™ score was positively correlated to hop distance, and limb asymmetry in FMS™ tasks was correlated to limb asymmetry in 6m hop time in football players. No significant correlations were observed between FMS™ score and hip and knee strength, or between FMS™ asymmetry and asymmetries in hip and knee strength between limbs. These results indicate that a simple hop for distance test may be a time and cost efficient alternative to FMS™ testing in athletes and that functional asymmetries between limbs do not coincide with strength asymmetries. PMID:26886801

  10. Polarization-direction correlation measurement --- Experimental test of the PDCO methods

    NASA Astrophysics Data System (ADS)

    Starosta, K.; Morek, T.; Droste, Ch.; Rohoziński, S. G.; Srebrny, J.; Bergstrem, M.; Herskind, B.

    1998-04-01

    Information about spins and parities of excited states is crucial for nuclear structure studies. In ``in-beam" gamma ray spectroscopy the directional correlation (DCO) or angular distribution measurements are widely used tools for multipolarity assignment; although, it is known that neither of these methods is sensitive to electric or magnetic character of gamma radiation. Multipolarity of gamma rays may be determined when the results of the DCO analysis are combined with the results of linear polarization measurements. The large total efficiency of modern multidetector arrays allows one to carry out coincidence measurements between the polarimeter and the remaining detectors. The aim of the present study was to test experimentally the possibility of polarization-direction correlation measurements using the EUROGAM II array. The studied nucleus was ^164Yb produced in the ^138Ba(^30Si,4n) reaction at beam energies of 150 and 155 MeV. The angular correlation, linear polarization and direction-polarization correlation were measured for the strong transitions in yrast and non yrast cascades. Application of the PDCO analysis to a transition connecting a side band with the yrast band allowed one to rule out most of the ambiguities in multipolarity assignment occuring if one used angular correlations only.

  11. 1H-MR spectroscopy metabolite levels correlate with executive function in vascular cognitive impairment

    PubMed Central

    Gasparovic, Charles; Prestopnik, Jillian; Thompson, Jeffrey; Taheri, Saeid; Huisa, Branko; Schrader, Ronald; Adair, John C; Rosenberg, Gary A

    2013-01-01

    Background White matter hyperintensities (WMHs) are associated with vascular cognitive impairment (VCI) but fail to correlate with neuropsychological measures. As proton MR spectroscopy (1H-MRS) can identify ischaemic tissue, we hypothesised that MRS detectable brain metabolites would be superior to WMHs in predicting performance on neuropsychological tests. Methods 60 patients with suspected VCI underwent clinical, neuropsychological, MRI and CSF studies. They were diagnosed as having subcortical ischaemic vascular disease (SIVD), multiple infarcts, mixed dementia and leukoaraiosis. We measured brain metabolites in a white matter region above the lateral ventricles with 1H-MRS and WMH volume in this region and throughout the brain. Results We found a significant correlation between both total creatine (Cr) and N-acetylaspartyl compounds (NAA) and standardised neuropsychological test scores. Cr levels in white matter correlated significantly with executive function (p=0.001), attention (p=0.03) and overall T score (p=0.007). When lesion volume was added as a covariate, NAA also showed a significant correlation with executive function (p=0.003) and overall T score (p=0.015). Furthermore, while metabolite levels also correlated with total white matter lesion volume, adjusting the Cr levels for lesion volume did not diminish the strength of the association between Cr levels and neuropsychological scores. The lowest metabolite levels and neuropsychological scores were found in the SIVD group. Finally, lesion volume alone did not correlate significantly with any neuropsychological test score. Conclusion These results suggest that estimates of neurometabolite levels provide additional and useful information concerning cognitive function in VCI not obtainable by measurements of lesion load. PMID:23418212

  12. Diffusion-weighted MRI of the pancreas: correlation with secretin endoscopic pancreatic function test (ePFT).

    PubMed

    Balci, N Cem; Momtahen, Amir Javad; Akduman, E Isin; Alkaade, Samer; Bilgin, Mehmet; Burton, Frank R

    2008-10-01

    To evaluate the correlation between apparent diffusion coefficient (ADC) values of the pancreas on diffusion-weighted imaging (DWI) and pancreatic exocrine function determined by HCO(3) concentration in the secretin endoscopic pancreatic function test (ePFT). Mean ADC values derived from 10 different points of the pancreatic gland on DWI were reviewed in 14 patients with normal (peak HCO(3) > or = 80 mEq/L) and 14 patients with abnormal (peak HCO(3) < 80 mEq/L) ePFT results. Magnetic resonance cholangiopancreatography (MRCP) images of the same patients were evaluated for the diagnosis of chronic pancreatitis. Correlation between ADC values and HCO(3) concentration as well as Cambridge scores in MRCP was performed using Spearman's correlation test. Mean ADC value of the pancreas was 1.52 +/- 0.13 x 10(-3) mm(2)/s in patients with abnormal ePFT results and 1.78 +/- 0.07 x 10(-3) mm(2)/s in the normal group. There was a significant statistical difference between the ADC values of the pancreas in the two groups (P < .0001). There was also a statistically significant correlation between HCO(3) level and ADC value of the pancreas in the study patients (r = 0.771, P < .0001). Morphologic changes of the pancreas according to the Cambridge classification were also well correlated with the mean ADC values (r = -0.763, P < .0001). Strong correlation between ADC value and pancreatic exocrine function as well as Cambridge score for chronic pancreatitis exists. Further studies are needed to determine the cut off ADC value for chronic pancreatitis.

  13. Universality, correlations, and rankings in the Brazilian universities national admission examinations

    NASA Astrophysics Data System (ADS)

    da Silva, Roberto; Lamb, Luis C.; Barbosa, Marcia C.

    2016-09-01

    We analyze the scores obtained by students who have taken the ENEM examination, The Brazilian High School National Examination which is used in the admission process at Brazilian universities. The average high schools scores from different disciplines are compared through the Pearson correlation coefficient. The results show a very large correlation between the performance in the different school subjects. Even though the students' scores in the ENEM form a Gaussian due to the standardization, we show that the high schools' scores form a bimodal distribution that cannot be used to evaluate and compare students performance over time. We also show that this high schools distribution reflects the correlation between school performance and the economic level (based on the average family income) of the students. The ENEM scores are compared with a Brazilian non standardized exam, the entrance examination from the Universidade Federal do Rio Grande do Sul. The analysis of the performance of the same individuals in both tests shows that the two tests not only select different abilities, but also lead to the admission of different sets of individuals. Our results indicate that standardized tests might be an interesting tool to compare performance of individuals over the years, but not of institutions.

  14. Using the Cross-Correlation Function to Evaluate the Quality of Eddy-Covariance Data

    NASA Astrophysics Data System (ADS)

    Qi, Yongfeng; Shang, Xiaodong; Chen, Guiying; Gao, Zhiqiu; Bi, Xueyan

    2015-11-01

    A cross-correlation test is proposed for evaluating the quality of 30-min eddy-covariance data. Cross-correlation as a function of time lag is computed for vertical velocity paired with temperature, humidity, and carbon dioxide concentration. High quality data have a dominant peak at zero time lag and approach zero within a time lag of 20 s. Poor quality data have erratic cross-correlation functions, which indicates that the eddy flux may no longer represent the energy and mass exchange between the atmospheric surface layer and the canopy, and such data should be rejected in post-data analyses. Eddy-covariance data over grassland in July 2004 are used to evaluate the proposed test. The results show that 17, 29, and 36 % of the available data should be rejected because of poor quality measurements of sensible heat, latent heat, and CO2 fluxes, respectively. The rejected data mainly occurred on calm nights and day/night transitions when the atmospheric surface layer became stable or neutrally stratified. We found no friction velocity (u_*) threshold below which all data should be rejected, a test that many other studies have implemented for rejecting questionable data. We instead found that some data with low u_* were reliable, whereas other data with higher u_* were not. The poor quality measurements collected under less than ideal conditions were replaced by using the mean diurnal variation gap-filling method. The correction for poor quality data shifted the daily average CO2 flux by +0.34 g C m^{-2} day^{-1}. After applying the quality-control test, the eddy CO2 fluxes did not display a clear dependence on u_*. The results suggest that the cross-correlation test is a potentially valuable step in evaluating the quality of eddy-covariance data.

  15. Monitoring of unfractionated heparin with rotational thrombelastometry using the prothrombinase-induced clotting time reagent (PiCT®).

    PubMed

    Schaden, E; Jilch, S; Hacker, S; Schober, A; Kozek-Langenecker, S

    2012-12-24

    To achieve sufficient and safe anticoagulation with unfractionated heparin (UFH) a close and reliable drug monitoring is necessary. In general, the activated partial thromboplastin time (APTT) is used for this purpose. In acute phase response, however, the APTT test procedure might be unreliable e.g. with false low results in the presence of elevated factor VIII. In this so called heparin resistance, measurement of anti-Xa activity is recommended over APTT to avoid potentially harmful dose escalation. A combination of anti-Xa measurement and global hemostatic testing with ROTEM® employing the anti-Xa sensitive PiCT® reagent showed high correlation with enoxaparin levels. This test modification could also be suitable for monitoring UFH. Aim of the study was to evaluate the correlation between PiCT®-ROTEM® and levels of UFH. In this in-vitro study blood samples from healthy volunteers were spiked with UFH and subjected to different ROTEM® tests. There was a linear correlation between UFH level and clotting time (CT) in the PiCT®-ROTEM® test with an excellent correlation coefficient of 0.92. Additional endpoints showed similar results (PiCT®-ROTEM® MaxVel r = -0.85 and PiCT®-ROTEM® t_MaxVel r = 0.88). As a point-of-care applicable tool ROTEM® is immediately at hand. If further clinical studies confirm sensitivity in heparin resistance, PiCT®-ROTEM® could permit rapid UFH dose adjustments especially required in critical illness with acute phase response. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Y balance test has no correlation with the Stability Index of the Biodex Balance System.

    PubMed

    Almeida, Gabriel Peixoto Leão; Monteiro, Isabel Oliveira; Marizeiro, Débora Fortes; Maia, Laísa Braga; de Paula Lima, Pedro Olavo

    2017-02-01

    A cross-sectional study design. The Stability Index of the Biodex Balance System (SI-BBS) and Y Balance Test (YBT) has been used in studies assessing postural stability but no studies have verified the association of the YBT with the SI-BBS. To analyze the association of the Y Balance Test (YBT) with the Stability Index of the Biodex Balance System (SI-BBS) to evaluate postural stability. Forty participants who engaged in recreational physical activities, 12 of whom had a history of injury to the lower limbs. Was used the SI-BBS and the anterior, posterolateral, posteromedial, and composite measures of the YBT. The order of execution of the tests and of the lower limbs evaluated was randomized and blind tested by two evaluators. Pearson's correlation coefficient was used to check the strength of the relationship between the distances achieved on the YBT and the SI-BBS. The YBT showed excellent reliability in the anterior, posteromedial, and posterolateral directions. However, the YBT showed no statistically significant correlation with any variables in the SI-BBS, indicating poor validity between YBT and SI-BBS assessments of postural stability in people with and without history of lower limb injuries. The results of this study showed the YBT is not correlated with the SI-BBS as an assessment of postural stability. This finding has implications for researchers and clinicians using YBT results as the only measure of postural stability. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Sensitivities of Soap Solutions in Leak Detection

    NASA Technical Reports Server (NTRS)

    Stuck, D.; Lam, D. Q.; Daniels, C.

    1985-01-01

    Document describes method for determining minimum leak rate to which soap-solution leak detectors sensitive. Bubbles formed at smaller leak rates than previously assumed. In addition to presenting test results, document discusses effects of joint-flange configurations, properties of soap solutions, and correlation of test results with earlier data.

  18. Correlation between plasma endothelin-1 levels and severity of septic liver failure quantified by maximal liver function capacity (LiMAx test). A prospective study.

    PubMed

    Kaffarnik, Magnus F; Ahmadi, Navid; Lock, Johan F; Wuensch, Tilo; Pratschke, Johann; Stockmann, Martin; Malinowski, Maciej

    2017-01-01

    To investigate the relationship between the degree of liver dysfunction, quantified by maximal liver function capacity (LiMAx test) and endothelin-1, TNF-α and IL-6 in septic surgical patients. 28 septic patients (8 female, 20 male, age range 35-80y) were prospectively investigated on a surgical intensive care unit. Liver function, defined by LiMAx test, and measurements of plasma levels of endothelin-1, TNF-α and IL-6 were carried out within the first 24 hours after onset of septic symptoms, followed by day 2, 5 and 10. Patients were divided into 2 groups (group A: LiMAx ≥100 μg/kg/h, moderate liver dysfunction; group B: LiMAx <100 μg/kg/h, severe liver dysfunction) for analysis and investigated regarding the correlation between endothelin-1 and the severity of liver failure, quantified by LiMAx test. Group B showed significant higher results for endothelin-1 than patients in group A (P = 0.01, d5; 0.02, d10). For TNF-α, group B revealed higher results than group A, with a significant difference on day 10 (P = 0.005). IL-6 showed a non-significant trend to higher results in group B. The Spearman's rank correlation coefficient revealed a significant correlation between LiMAx and endothelin-1 (-0.434; P <0.001), TNF-α (-0.515; P <0.001) and IL-6 (-0.590; P <0.001). Sepsis-related hepatic dysfunction is associated with elevated plasma levels of endothelin-1, TNF-α and IL-6. Low LiMAx results combined with increased endothelin-1 and TNF-α and a favourable correlation between LiMAx and cytokine values support the findings of a crucial role of Endothelin-1 and TNF-α in development of septic liver failure.

  19. Evaluation of dysphagia in early stroke patients by bedside, endoscopic, and electrophysiological methods.

    PubMed

    Umay, Ebru Karaca; Unlu, Ece; Saylam, Guleser Kılıc; Cakci, Aytul; Korkmaz, Hakan

    2013-09-01

    We aimed in this study to evaluate dysphagia in early stroke patients using a bedside screening test and flexible fiberoptic endoscopic evaluation of swallowing (FFEES) and electrophysiological evaluation (EE) methods and to compare the effectiveness of these methods. Twenty-four patients who were hospitalized in our clinic within the first 3 months after stroke were included in this study. Patients were evaluated using a bedside screening test [including bedside dysphagia score (BDS), neurological examination dysphagia score (NEDS), and total dysphagia score (TDS)] and FFEES and EE methods. Patients were divided into normal-swallowing and dysphagia groups according to the results of the evaluation methods. Patients with dysphagia as determined by any of these methods were compared to the patients with normal swallowing based on the results of the other two methods. Based on the results of our study, a high BDS was positively correlated with dysphagia identified by FFEES and EE methods. Moreover, the FFEES and EE methods were positively correlated. There was no significant correlation between NEDS and TDS levels and either EE or FFEES method. Bedside screening tests should be used mainly as an initial screening test; then FFEES and EE methods should be combined in patients who show risks. This diagnostic algorithm may provide a practical and fast solution for selected stroke patients.

  20. Synthesizing Information From Language Samples and Standardized Tests in School-Age Bilingual Assessment

    PubMed Central

    Pham, Giang

    2017-01-01

    Purpose Although language samples and standardized tests are regularly used in assessment, few studies provide clinical guidance on how to synthesize information from these testing tools. This study extends previous work on the relations between tests and language samples to a new population—school-age bilingual speakers with primary language impairment—and considers the clinical implications for bilingual assessment. Method Fifty-one bilingual children with primary language impairment completed narrative language samples and standardized language tests in English and Spanish. Children were separated into younger (ages 5;6 [years;months]–8;11) and older (ages 9;0–11;2) groups. Analysis included correlations with age and partial correlations between language sample measures and test scores in each language. Results Within the younger group, positive correlations with large effect sizes indicated convergence between test scores and microstructural language sample measures in both Spanish and English. There were minimal correlations in the older group for either language. Age related to English but not Spanish measures. Conclusions Tests and language samples complement each other in assessment. Wordless picture-book narratives may be more appropriate for ages 5–8 than for older children. We discuss clinical implications, including a case example of a bilingual child with primary language impairment, to illustrate how to synthesize information from these tools in assessment. PMID:28055056

  1. Development and evaluation of an enzyme-labeled antibody test for the rapid detection of hog cholera antibodies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saunders, G.C.

    1977-01-01

    A rapid enzyme-labeled antibody (ELA) microtechnique for the screening of swine for hog cholera antibodies was developed and evaluated with a blind study, using a 640-sample hog cholera serum bank. The total time to run a group of 22 samples was approximately 1 hour. The ELA test results correlated >99% with hog cholera serum-neutralization test results on the same serums. Test results also indicated that the ELA test shares with the hog cholera serum-neutralization test the problem of cross reactions between the antibodies of hog cholera and bovine viral diarrhea.

  2. Price-volume multifractal analysis of the Moroccan stock market

    NASA Astrophysics Data System (ADS)

    El Alaoui, Marwane

    2017-11-01

    In this paper, we analyzed price-volume multifractal cross-correlations of Moroccan Stock Exchange. We chose the period from January 1st 2000 to January 20th 2017 to investigate the multifractal behavior of price change and volume change series. Then, we used multifractal detrended cross-correlations analysis method (MF-DCCA) and multifractal detrended fluctuation analysis (MF-DFA) to analyze the series. We computed bivariate generalized Hurst exponent, Rényi exponent and spectrum of singularity for each pair of indices to measure quantitatively cross-correlations. Furthermore, we used detrended cross-correlations coefficient (DCCA) and cross-correlation test (Q(m)) to analyze cross-correlation quantitatively and qualitatively. By analyzing results, we found existence of price-volume multifractal cross-correlations. The spectrum width has a strong multifractal cross-correlation. We remarked that volume change series is anti-persistent when we analyzed the generalized Hurst exponent for all moments q. The cross-correlation test showed the presence of a significant cross-correlation. However, DCCA coefficient had a small positive value, which means that the level of correlation is not very significant. Finally, we analyzed sources of multifractality and their degree of contribution in the series.

  3. High-level language ability in healthy individuals and its relationship with verbal working memory.

    PubMed

    Antonsson, Malin; Longoni, Francesca; Einald, Christina; Hallberg, Lina; Kurt, Gabriella; Larsson, Kajsa; Nilsson, Tina; Hartelius, Lena

    2016-01-01

    The aims of the study were to investigate healthy subjects' performance on a clinical test of high-level language (HLL) and how it is related to demographic characteristics and verbal working memory (VWM). One hundred healthy subjects (20-79 years old) were assessed with the Swedish BeSS test (Laakso, Brunnegård, Hartelius, & Ahlsén, 2000) and two digit span tasks. Relationships between the demographic variables, VWM and BeSS were investigated both with bivariate correlations and multiple regression analysis. The results present the norms for BeSS. The correlations and multiple regression analysis show that demographic variables had limited influence on test performance. Measures of VWM were moderately related to total BeSS score and weakly to moderately correlated with five of the seven subtests. To conclude, education has an influence on the test as a whole but measures of VWM stood out as the most robust predictor of HLL.

  4. Investigation of fatigue failure in bituminous base mixes.

    DOT National Transportation Integrated Search

    1980-01-01

    A correlation between the results obtained with the fatigue test and those from the indirect tensile test on two base mixes was attempted in anticipation of the possible use of the latter test to design base mixes for maximum fatigue life. Two base m...

  5. Validation of a brief telephone battery for neurocognitive assessment of patients with pulmonary arterial hypertension.

    PubMed

    Taichman, Darren B; Christie, Jason; Biester, Rosette; Mortensen, Jennifer; White, Joanne; Kaplan, Sandra; Hansen-Flaschen, John; Palevsky, Harold I; Elliott, C Gregory; Hopkins, Ramona O

    2005-04-25

    The effects of pulmonary arterial hypertension on brain function are not understood, despite patients' frequent complaints of cognitive difficulties. Using clinical instruments normally administered during standard in-person assessment of neurocognitive function in adults, we assembled a battery of tests designed for administration over the telephone. The purpose was to improve patient participation, facilitate repeated test administration, and reduce the cost of research on the neuropsychological consequences of acute and chronic cardiorespiratory diseases. We undertook this study to validate telephone administration of the tests. 23 adults with pulmonary arterial hypertension underwent neurocognitive assessment using both standard in-person and telephone test administration, and the results of the two methods compared using interclass correlations. For most of the tests in the battery, scores from the telephone assessment correlated strongly with those obtained by in-person administration of the same tests. Interclass correlations between 0.5 and 0.8 were observed for tests that assessed attention, memory, concentration/working memory, reasoning, and language/crystallized intelligence (p < or = 0.05 for each). Interclass correlations for the Hayling Sentence Completion test of executive function approached significance (p = 0.09). All telephone tests were completed within one hour. Administration of this neurocognitive test battery by telephone should facilitate assessment of neuropsychological deficits among patients with pulmonary arterial hypertension living across broad geographical areas, and may be useful for monitoring changes in neurocognitive function in response to PAH-specific therapy or disease progression.

  6. Correlation of etho-social and psycho-social data from "Mars-500" interplanetary simulation

    NASA Astrophysics Data System (ADS)

    Tafforin, Carole; Vinokhodova, Alla; Chekalina, Angelina; Gushin, Vadim

    2015-06-01

    Studies of social groups under isolation and confinement for the needs of space psychology were mostly limited by questionnaires completed with batteries of subjective tests, and they needed to be correlated with video recordings for objective analyses in space ethology. The aim of the present study is to identify crewmembers' behavioral profiles for better understanding group dynamics during a 520-day isolation and confinement of the international crew (n=6) participating to the "Mars-500" interplanetary simulation. We propose to correlate data from PSPA (Personal Self-Perception and Attitudes) computerized test, sociometric questionnaires and color choices test (Luscher test) used to measure anxiety levels, with data of video analysis during group discussion (GD) and breakfast time (BT). All the procedures were implemented monthly - GD, or twice a month - BT. Firstly, we used descriptive statistics for displaying quantitative subjects' behavioral profiles, supplied with a software based-solution: the Observer XT®. Secondly, we used Spearmen's nonparametric correlation analysis. The results show that for each subject, the level of non-verbal behavior ("visual interactions", "object interactions", "body interaction", "personal actions", "facial expressions", and "collateral acts") is higher than the level of verbal behavior ("interpersonal communication in Russian", and "interpersonal communication in English"). From the video analyses, dynamics profiles over months are different between the crewmembers. From the correlative analyses, we found highly negative correlations between anxiety and interpersonal communications; and between the sociometric parameter "popularity in leisure environment" and anxiety level. We also found highly significant positive correlations between the sociometric parameter "popularity in working environment" and interpersonal communications, and facial expressions; and between the sociometric parameter "popularity in leisure environment " and interpersonal communications, and facial expressions. As a whole, the findings show high importance of ethological investigations with video monitoring for assessment of group behavior in extreme environment. At the same time, correct interpretation of the video recording results requires their comparison with the results of classical socio-psychological methods. We discuss about the different approaches: objective vs. subjective; active vs. discursive; exhaustive vs. restrictive; descriptive vs. introspective.

  7. Psychological Correlates of College Students Referred to a Learning Needs Center.

    ERIC Educational Resources Information Center

    Lefebvre, R. Craig

    The paper considers issues in intelligence testing of learning disabled (LD) children and adults and reviews results of psychological testing of LD students at the University of Virginia (UVA). Tests administered include neurological screening tests and personality assessments where appropriate. It is explained that the matriculating LD student is…

  8. Functional Fitness Testing Results Following Long-Duration ISS Missions.

    PubMed

    Laughlin, Mitzi S; Guilliams, Mark E; Nieschwitz, Bruce A; Hoellen, David

    2015-12-01

    Long-duration spaceflight missions lead to the loss of muscle strength and endurance. Significant reduction in muscle function can be hazardous when returning from spaceflight. To document these losses, NASA developed medical requirements that include measures of functional strength and endurance. Results from this Functional Fitness Test (FFT) battery are also used to evaluate the effectiveness of in-flight exercise countermeasures. The purpose of this paper is to document results from the FFT and correlate this information with performance of in-flight exercise on board the International Space Station. The FFT evaluates muscular strength and endurance, flexibility, and agility and includes the following eight measures: sit and reach, cone agility, push-ups, pull-ups, sliding crunches, bench press, leg press, and hand grip dynamometry. Pre- to postflight functional fitness measurements were analyzed using dependent t-tests and correlation analyses were used to evaluate the relationship between functional fitness measurements and in-flight exercise workouts. Significant differences were noted post space flight with the sit and reach, cone agility, leg press, and hand grip measurements while other test scores were not significantly altered. The relationships between functional fitness and in-flight exercise measurements showed minimal to moderate correlations for most in-flight exercise training variables. The change in FFT results can be partially explained by in-flight exercise performance. Although there are losses documented in the FFT results, it is important to realize that the crewmembers are successfully performing activities of daily living and are considered functional for normal activities upon return to Earth.

  9. FM-MAP: A Novel In-Training Examination Predicts Success on Family Medicine Certification Examination.

    PubMed

    Iglar, Karl; Leung, Fok-Han; Moineddin, Rahim; Herold, Jodi

    2017-05-01

    The objective of our study was to assess the correlation between a locally developed In-Training Examination (ITE) and the certification examination in family medicine in Canada. The ITE was taken twice yearly, which corresponded for most residents to the fifth, ninth, 17th, and 21st month of training. The results for the ITE were correlated to the CFPC certification examination taken in the 23rd month of residency. The scores on each of the four iterations of the ITE correlated moderately well with performance relating to problem solving skills and knowledge on the certification examination. The ITE showed a trend to an increased correlation with duration in the training program with a Spearman correlation coefficient increasing from 0.45 on the first test to 0.54 on the fourth test. The correlation of the ITE with performance on the component assessing the doctor- patient relationship on the certification examination was poor (r=0.26 on the last test). Our in-training examination is a useful predictor of performance in problem solving and knowledge domains of the family medicine expert role on the certification examination.

  10. Transformation Abilities: A Reanalysis and Confirmation of SOI Theory.

    ERIC Educational Resources Information Center

    Khattab, Ali-Maher; And Others

    1987-01-01

    Confirmatory factor analysis was used to reanalyze correlational data from selected variables in Guilford's Aptitudes Research Project. Results indicated Guilford's model reproduced the original correlation matrix more closely than other models. Most of Guilford's tests indicated high loadings on their hypothesized factors. (GDC)

  11. Correlation of nutritional status with academic achievement in adolescents

    NASA Astrophysics Data System (ADS)

    Sinurat, R. S.; Sembiring, T.; Azlin, E.; Faranita, T.; Pratita, W.

    2018-03-01

    Malnutrition is considered a problem that limits learning ability (cognitive function), which is related to poor academic achievement results. This study aimed to determine the relationship of nutritional status with academic achievement in adolescents. A cross-sectional study was conducted on 126 junior high school students ranging from 12 to 15 years in Batubara, North Sumatra in January 2015. Nutritional status is determined by weight for height. Academic achievement was recorded from the final results of their school exams. The value of intelligence quotient (IQ) was assessed by using the Aptitude Test. Data were then analyzed by using Spearman correlation and Chi-Square test. In conclusion, there was no significant difference between nutritional status with IQ score (p=0,540) but showed a significant relationship (p=0.003) between normal nutritional status with the total value of the report card with positive weak correlation strength (r=0.342). There was also a significant difference (p=0.020) and moderate positive correlation (r=0.541) between overweight with academic achievement based on mathematics.

  12. Profiling Online Poker Players: Are Executive Functions Correlated with Poker Ability and Problem Gambling?

    PubMed

    Schiavella, Mauro; Pelagatti, Matteo; Westin, Jerker; Lepore, Gabriele; Cherubini, Paolo

    2018-01-12

    Poker playing and responsible gambling both entail the use of the executive functions (EF), which are higher-level cognitive abilities. This study investigated if online poker players of different ability showed different performances in their EF and if so, which functions were the most discriminating for their playing ability. Furthermore, it assessed if the EF performance was correlated to the quality of gambling, according to self-reported questionnaires (PGSI, SOGS, GRCS). Three poker experts evaluated anonymized poker hand history files and, then, a trained professional administered an extensive neuropsychological test battery. Data analysis determined which variables of the tests correlated with poker ability and gambling quality scores. The highest correlations between EF test results and poker ability and between EF test results and gambling quality assessment showed that mostly different clusters of executive functions characterize the profile of the strong(er) poker player and those ones of the problem gamblers (PGSI and SOGS) and the one of the cognitions related to gambling (GRCS). Taking into consideration only the variables overlapping between PGSI and SOGS, we found some key predictive factors for a more risky and harmful online poker playing: a lower performance in the emotional intelligence competences (Emotional Quotient inventory Short) and, in particular, those grouped in the Intrapersonal scale (emotional self-awareness, assertiveness, self-regard, independence and self-actualization).

  13. CT densitovolumetry in children with obliterative bronchiolitis: correlation with clinical scores and pulmonary function test results*,**

    PubMed Central

    Mocelin, Helena; Bueno, Gilberto; Irion, Klaus; Marchiori, Edson; Sarria, Edgar; Watte, Guilherme; Hochhegger, Bruno

    2013-01-01

    OBJECTIVE: To determine whether air trapping (expressed as the percentage of air trapping relative to total lung volume [AT%]) correlates with clinical and functional parameters in children with obliterative bronchiolitis (OB). METHODS: CT scans of 19 children with OB were post-processed for AT% quantification with the use of a fixed threshold of −950 HU (AT%950) and of thresholds selected with the aid of density masks (AT%DM). Patients were divided into three groups by AT% severity. We examined AT% correlations with oxygen saturation (SO2) at rest, six-minute walk distance (6MWD), minimum SO2 during the six-minute walk test (6MWT_SO2), FVC, FEV1, FEV1/FVC, and clinical parameters. RESULTS: The 6MWD was longer in the patients with larger normal lung volumes (r = 0.53). We found that AT%950 showed significant correlations (before and after the exclusion of outliers, respectively) with the clinical score (r = 0.72; 0.80), FVC (r = 0.24; 0.59), FEV1 (r = −0.58; −0.67), and FEV1/FVC (r = −0.53; r = −0.62), as did AT%DM with the clinical score (r = 0.58; r = 0.63), SO2 at rest (r = −0.40; r = −0.61), 6MWT_SO2 (r = −0.24; r = −0.55), FVC (r = −0.44; r = −0.80), FEV1 (r = −0.65; r = −0.71), and FEV1/FVC (r = −0.41; r = −0.52). CONCLUSIONS: Our results show that AT% correlates significantly with clinical scores and pulmonary function test results in children with OB. PMID:24473764

  14. Summary of directional divergence characteristics of several high performance aircraft configurations

    NASA Technical Reports Server (NTRS)

    Greer, H. D.

    1972-01-01

    The present paper summarizes the high-angle-of-attack characteristics of a number of high-performance aircraft as determined from model force tests and free-flight model tests and correlates these characteristics with the dynamic directional-stability parameter. This correlation shows that the dynamic directional-stability parameter correlates fairly well with directional divergence. Data are also presented to show the effect of some airframe modifications on the directional divergence potential of the configuration. These results show that leading-edge slates seem to be the most effective airframe modification for reducing or eliminating the directional divergence potential of aircraft with moderately swept wings.

  15. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment.

    PubMed

    Nornoo, Adwoa O; Jackson, Jonathan; Axtell, Samantha

    2017-03-25

    Objective. To determine whether there is a correlation between pharmacy students' scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman's rho correlation test was performed. Results. A very weak but significant positive correlation was found between students' grades on the assignment and their overall HSRT score (r=0.19, p <0.05), as well as deduction (a scale score of the HSRT; r=0.26, p <0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students.

  16. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment

    PubMed Central

    Jackson, Jonathan; Axtell, Samantha

    2017-01-01

    Objective. To determine whether there is a correlation between pharmacy students’ scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman’s rho correlation test was performed. Results. A very weak but significant positive correlation was found between students’ grades on the assignment and their overall HSRT score (r=0.19, p<0.05), as well as deduction (a scale score of the HSRT; r=0.26, p<0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students. PMID:28381884

  17. Detrended Partial-Cross-Correlation Analysis: A New Method for Analyzing Correlations in Complex System

    PubMed Central

    Yuan, Naiming; Fu, Zuntao; Zhang, Huan; Piao, Lin; Xoplaki, Elena; Luterbacher, Juerg

    2015-01-01

    In this paper, a new method, detrended partial-cross-correlation analysis (DPCCA), is proposed. Based on detrended cross-correlation analysis (DCCA), this method is improved by including partial-correlation technique, which can be applied to quantify the relations of two non-stationary signals (with influences of other signals removed) on different time scales. We illustrate the advantages of this method by performing two numerical tests. Test I shows the advantages of DPCCA in handling non-stationary signals, while Test II reveals the “intrinsic” relations between two considered time series with potential influences of other unconsidered signals removed. To further show the utility of DPCCA in natural complex systems, we provide new evidence on the winter-time Pacific Decadal Oscillation (PDO) and the winter-time Nino3 Sea Surface Temperature Anomaly (Nino3-SSTA) affecting the Summer Rainfall over the middle-lower reaches of the Yangtze River (SRYR). By applying DPCCA, better significant correlations between SRYR and Nino3-SSTA on time scales of 6 ~ 8 years are found over the period 1951 ~ 2012, while significant correlations between SRYR and PDO on time scales of 35 years arise. With these physically explainable results, we have confidence that DPCCA is an useful method in addressing complex systems. PMID:25634341

  18. Specific Features of Executive Dysfunction in Alzheimer-Type Mild Dementia Based on Computerized Cambridge Neuropsychological Test Automated Battery (CANTAB) Test Results.

    PubMed

    Kuzmickienė, Jurgita; Kaubrys, Gintaras

    2016-10-08

    BACKGROUND The primary manifestation of Alzheimer's disease (AD) is decline in memory. Dysexecutive symptoms have tremendous impact on functional activities and quality of life. Data regarding frontal-executive dysfunction in mild AD are controversial. The aim of this study was to assess the presence and specific features of executive dysfunction in mild AD based on Cambridge Neuropsychological Test Automated Battery (CANTAB) results. MATERIAL AND METHODS Fifty newly diagnosed, treatment-naïve, mild, late-onset AD patients (MMSE ≥20, AD group) and 25 control subjects (CG group) were recruited in this prospective, cross-sectional study. The CANTAB tests CRT, SOC, PAL, SWM were used for in-depth cognitive assessment. Comparisons were performed using the t test or Mann-Whitney U test, as appropriate. Correlations were evaluated by Pearson r or Spearman R. Statistical significance was set at p<0.05. RESULTS AD and CG groups did not differ according to age, education, gender, or depression. Few differences were found between groups in the SOC test for performance measures: Mean moves (minimum 3 moves): AD (Rank Sum=2227), CG (Rank Sum=623), p<0.001. However, all SOC test time measures differed significantly between groups: SOC Mean subsequent thinking time (4 moves): AD (Rank Sum=2406), CG (Rank Sum=444), p<0.001. Correlations were weak between executive function (SOC) and episodic/working memory (PAL, SWM) (R=0.01-0.38) or attention/psychomotor speed (CRT) (R=0.02-0.37). CONCLUSIONS Frontal-executive functions are impaired in mild AD patients. Executive dysfunction is highly prominent in time measures, but minimal in performance measures. Executive disorders do not correlate with a decline in episodic and working memory or psychomotor speed in mild AD.

  19. Correlation to FVIII:C in Two Thrombin Generation Tests: TGA-CAT and INNOVANCE ETP.

    PubMed

    Ljungkvist, Marcus; Berndtsson, Maria; Holmström, Margareta; Mikovic, Danijela; Elezovic, Ivo; Antovic, Jovan P; Zetterberg, Eva; Berntorp, Erik

    2017-01-01

    Several thrombin-generation tests are available, but few have been directly compared. Our primary aim was to investigate the correlation of two thrombin generation tests, thrombin generation assay-calibrated automated thrombogram (TGA-CAT) and INNOVANCE ETP, to factor VIII levels (FVIII:C) in a group of patients with hemophilia A. The secondary aim was to investigate inter-laboratory variation for the TGA-CAT method. Blood samples were taken from 45 patients with mild, moderate and severe hemophilia A. The TGA-CAT method was performed at both centers while the INNOVANCE ETP was only performed at the Stockholm center. Correlation between parameters was evaluated using Spearman's rank correlation test. For determination of the TGA-CAT inter-laboratory variability, Bland-Altman plots were used. The correlation for the INNOVANCE ETP and TGA-CAT methods with FVIII:C in persons with hemophilia (PWH) was r=0.701 and r=0.734 respectively.The correlation between the two methods was r=0.546.When dividing the study material into disease severity groups (mild, moderate and severe) based on FVIII levels, both methods fail to discriminate between them.The variability of the TGA-CAT results performed at the two centers was reduced after normalization; before normalization, 29% of values showed less than ±10% difference while after normalization the number increased to 41%. Both methods correlate in an equal manner to FVIII:C in PWH but show a poor correlation with each other. The level of agreement for the TGA-CAT method was poor though slightly improved after normalization of data. Further improvement of standardization of these methods is warranted.

  20. Predicting Work Activities with Divergent Thinking Tests: A Longitudinal Study

    ERIC Educational Resources Information Center

    Clapham, Maria M.; Cowdery, Edwina M.; King, Kelly E.; Montang, Melissa A.

    2005-01-01

    This study examined whether divergent thinking test scores obtained from engineering students during college predicted creative work activities fifteen years later. Results showed that a subscore of the "Owens Creativity Test", which assesses divergent thinking about mechanical objects, correlated significantly with self-ratings of…

  1. Summer performance results obtained from simultaneously testing ten solar collectors outdoors

    NASA Technical Reports Server (NTRS)

    Miller, D. R.

    1977-01-01

    Ten solar collectors were simultaneously tested outdoors. Efficiency data were correlated using a method that separates solar variables (flux, incident angle) from the desired performance parameters (heat loss, absorbtance, transmittance) which are unique to a given collector design. Tests were conducted on both clear and moderately cloudy days. Correlating data in the above manner, a 2-glass, black paint collector exhibited a decrease in efficiency of 5 percentage points relative to the baseline data for an exposure time of 2 years, 4 months. Condensation on the collector glazing was thought to be a contributing factor in this efficiency change.

  2. Effects of static tensile load on the thermal expansion of Gr/PI composite material

    NASA Technical Reports Server (NTRS)

    Farley, G. L.

    1981-01-01

    The effect of static tensile load on the thermal expansion of Gr/PI composite material was measured for seven different laminate configurations. A computer program was developed which implements laminate theory in a piecewise linear fashion to predict the coupled nonlinear thermomechanical behavior. Static tensile load significantly affected the thermal expansion characteristics of the laminates tested. This effect is attributed to a fiber instability micromechanical behavior of the constituent materials. Analytical results correlated reasonably well with free thermal expansion tests (no load applied to the specimen). However, correlation was poor for tests with an applied load.

  3. Biochemical differences in the mass and activity tests of lipoprotein-associated phospholipase A2 explain the discordance in results between the two assay methods.

    PubMed

    Zhuo, Shaoqiu; Wolfert, Robert L; Yuan, Chong

    2017-12-01

    There are two platforms for the detection of Lp-PLA 2 in sera or plasmas: by its enzymatic activity (PLAC® activity test) and by its mass concentration (PLAC® mass test). It has been long recognized that these two platforms are not correlated well. The underlying cause for this is therefore investigated by the biochemical characterization of the two PLAC tests. Human sera with and without the treatment by detergent were fractionated by using a Superose-6 column in phosphate buffered saline and the phospholipid associated Lp-PLA 2 was assessed by both PLAC mass and activity tests. The Lp-PLA 2 values of the two PLAC tests were compared under such conditions. Fractionation of sera and plasmas indicates that the association of Lp-PLA 2 with phospholipids, especially LDL and other large size phospholipid vesicles, may block the detection of the enzyme by antibodies in the immunoassay format under the conditions of the PLAC mass test. Inclusion of high concentration (>CMC, critical micelle concentration) of detergents in the assay buffer of PLAC mass test dissociates Lp-PLA 2 from phospholipid vesicles and results in the full detection of all Lp-PLA 2 in sera or plasmas for concentration. Such assay modification significantly improves the correlation between the PLAC mass and PLAC activity tests. PLAC mass test only detects a small portion of the total Lp-PLA 2 , mainly the Lp-PLA 2 associated with HDL. This is the main cause of the discordance and poor correlation between the PLAC mass and activity tests. Our results demonstrate the PLAC activity test is more accurate in assessing the total level of circulating Lp-PLA 2 . Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  4. Karolinska Scales of Personality, cognition and psychotic symptoms in patients with schizophrenia and healthy controls.

    PubMed

    Nilsson, Björn Mikael; Holm, Gunnar; Ekselius, Lisa

    2016-01-01

    Studies on both personality dimensions and cognition in schizophrenia are scarce. The objective of the present study was to examine personality traits and the relation to cognitive function and psychotic symptoms in a sample of patients with schizophrenia and healthy controls. In total 23 patients with schizophrenia and 14 controls were assessed with the Karolinska Scales of Personality (KSP). A broad cognitive test programme was used, including the Wechsler Adult Intelligence Scales, the Finger-Tapping Test, the Trail Making Test, the Verbal Fluency Test, the Benton Visual Retention Test, the Wisconsin Card Sorting Test and Rey Auditory Verbal Learning Test . Compared with controls, the patients exhibited prominent elevations on KSP scales measuring anxiety proneness and neuroticism (P = 0.000005-0.0001), on the Detachment scale (P < 0.00009) and lower value on the Socialization scale (P < 0.0002). The patients also scored higher on the Inhibition of Aggression, Suspicion, Guilt and Irritability scales (P = 0.002-0.03) while the remaining five scales did not differ between patients and controls. KSP anxiety-related scales correlated with the Positive and Negative Symptoms Scale (PANSS) general psychopathology subscale. Cognitive test results were uniformly lower in the patient group and correlated with PANSS negative symptoms subscale. There was no association between KSP scale scores and PANSS positive or negative symptoms. The patients revealed a highly discriminative KSP test profile with elevated scores in neuroticism- and psychoticism-related scales as compared to controls. Results support previous findings utilizing other personality inventories in patients with schizophrenia. Cognitive test performance correlated inversely with negative symptoms.

  5. Effects of Divergent Selection for Fear of Humans on Behaviour in Red Junglefowl

    PubMed Central

    Agnvall, Beatrix; Jensen, Per

    2016-01-01

    Domestication has caused a range of similar phenotypic changes across taxa, relating to physiology, morphology and behaviour. It has been suggested that this recurring domesticated phenotype may be a result of correlated responses to a central trait, namely increased tameness. We selected Red Junglefowl, the ancestors of domesticated chickens, during five generations for reduced fear of humans. This caused a marked and significant response in tameness, and previous studies have found correlated effects on growth, metabolism, reproduction, and some behaviour not directly selected for. Here, we report the results from a series of behavioural tests carried out on the initial parental generation (P0) and the fifth selected generation (S5), focusing on behaviour not functionally related to tameness, in order to study any correlated effects. Birds were tested for fear of humans, social reinstatement tendency, open field behaviour at two different ages, foraging/exploration, response to a simulated aerial predator attack and tonic immobility. In S5, there were no effects of selection on foraging/exploration or tonic immobility, while in the social reinstatement and open field tests there were significant interactions between selection and sex. In the aerial predator test, there were significant main effects of selection, indicating that fear of humans may represent a general wariness towards predators. In conclusion, we found only small correlated effects on behaviours not related to the tameness trait selected for, in spite of them showing high genetic correlations to fear of humans in a previous study on the same population. This suggests that species-specific behaviour is generally resilient to changes during domestication. PMID:27851792

  6. Effects of Divergent Selection for Fear of Humans on Behaviour in Red Junglefowl.

    PubMed

    Agnvall, Beatrix; Jensen, Per

    2016-01-01

    Domestication has caused a range of similar phenotypic changes across taxa, relating to physiology, morphology and behaviour. It has been suggested that this recurring domesticated phenotype may be a result of correlated responses to a central trait, namely increased tameness. We selected Red Junglefowl, the ancestors of domesticated chickens, during five generations for reduced fear of humans. This caused a marked and significant response in tameness, and previous studies have found correlated effects on growth, metabolism, reproduction, and some behaviour not directly selected for. Here, we report the results from a series of behavioural tests carried out on the initial parental generation (P0) and the fifth selected generation (S5), focusing on behaviour not functionally related to tameness, in order to study any correlated effects. Birds were tested for fear of humans, social reinstatement tendency, open field behaviour at two different ages, foraging/exploration, response to a simulated aerial predator attack and tonic immobility. In S5, there were no effects of selection on foraging/exploration or tonic immobility, while in the social reinstatement and open field tests there were significant interactions between selection and sex. In the aerial predator test, there were significant main effects of selection, indicating that fear of humans may represent a general wariness towards predators. In conclusion, we found only small correlated effects on behaviours not related to the tameness trait selected for, in spite of them showing high genetic correlations to fear of humans in a previous study on the same population. This suggests that species-specific behaviour is generally resilient to changes during domestication.

  7. [Applicability of syalometry and other instruments to evaluate xerostomia and xerophtalmia in a Sjögren's Syndrome outpatient clinic].

    PubMed

    Barcelos, Filipe; Patto, José Vaz; Parente, Manuela; Medeiros, Dina; Sousa, Miguel; Figueiredo, Rui; Miguel, Cláudia; Teixeira, Ana

    2009-01-01

    To evaluate the applicability and utility of unstimulated syalometry and instruments of evaluation of sicca complaints in a Sjögren's syndrome outpatient clinic. We performed unstimulated syalometry to 45 consecutive Primary Sjögren's Syndrome patients (PSS) and 21 healthy asymptomatic individuals age and sex-matched. PSS patients were further evaluated with Schirmer's test. We applied 3 published questionnaires to PSS patients: Xerostomia Inventory (XI), Oral Health Impact Profile-short form (OHIP) and Ocular Surface Disease Index (OSDI), and correlated the results with syalometry and Schirmer's test. Statistical analysis was performed with SPSS (Mann-Whitney U-test and Spearman's correlation). Salivary flux was significantly lower in PSS patients, as compared to controls (0.08+/-0.01 ml/min versus 0.38+/-0.25 ml/min, p=0.000), and decreased with age. Syalometry didn't correlate with Schirmer's test. OHIP scores (mean 26.8 points, ranging from 2 to 43 for a maximum of 56 points) didn't correlate with syalometry neither with Schirmer's test, but showed an association with the XI (p<0.0005) and OSDI (p<0.0005) tests. The XI questionnaire (mean 28.4 points, ranging from 11 to 41 for a maximum of 44 points) correlated with syalometry (p=0.018), with the OHIP questionary (p<0.0005) and with the OSDI scale (p=0.004), although it didn't correlate with Schirmer's test. OSDI scores (mean 56.5 points, ranging from 7 to 90 for a maximum of 100 points) didn't correlate with Schirmer's test neither with syalometry, but associated with the XI (p=0.004) and OHIP (p<0.0005) scales. Unstimulated syalometry is useful in the evaluation of patients suspected of suffering from Sjögren's syndrome, since it can confirm salivary hypofunction in a quick and cheap manner, allowing to differentiate between healthy individuals and patients. In a specialized clinic, the immediate availability of a salivary functional test is important in the classification of PSS or sicca syndrome. The xerostomia and xerophtalmia impact scales were mutually concordant, and since they evaluate the effects of the disease through time, could be helpful in our daily consultation.

  8. Use of digital image correlation to study the local deformation field of paper and paperboard

    Treesearch

    J.M. Considine; C.T. Scott; R. Gleisner; J.Y. Zhu

    2005-01-01

    Digital image correlation was used to measure the full-field deformation of paperboard and handsheet tensile specimens. The correlation technique was able to accurately measure strain in regions 0.6 by 0.6 mm. Results showed the variation of strain to be much larger than has been previously reported. For machine made paperboard tested in the cross-direction, the...

  9. Examination of the relationships between environmental exposures to volatile organic compounds and biochemical liver tests: application of canonical correlation analysis

    PubMed Central

    Liu, Jing; Drane, Wanzer; Liu, Xuefeng; Wu, Tiejian

    2009-01-01

    This study was to explore the relationships between personal exposure to ten volatile organic compounds (VOCs) and biochemical liver tests with the application of canonical correlation analysis. Data from a subsample of the 1999–2000 National Health and Nutrition Examination Survey were used. Serum albumin, total bilirubin (TB), alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), alkaline phosphatase (ALP), and γ-glutamyl transferase (GGT) served as the outcome variables. Personal exposures to benzene, chloroform, ethylbenzene, tetrachloroethene, toluene, trichloroethene, o-xylene, m-, p-xylene, 1,4-dichlorobenzene, and methyl tert-butyl ether (MTBE) were assessed through the use of passive exposure monitors worn by study participants. The first two canonical correlations were 0.3218 and 0.2575, suggesting a positive correlation mainly between the six VOCs (benzene, ethylbenzene, toluene, o-xylene, m-, p-xylene, and MTBE) and the three biochemical liver tests (albumin, ALP, and GGT) and a positive correlation mainly between the two VOCs (1,4-dichlorobenzene and tetrachloroethene) and the two biochemical liver tests (LDH and TB). Subsequent multiple linear regressions show that exposure to benzene, toluene, or MTBE was associated with serum albumin, while exposure to tetrachloroethene was associated with LDH and total bilirubin. In conclusion, exposure to certain VOCs as a group or individually may influence certain biochemical liver test results in the general population. PMID:19117555

  10. Examination of the relationships between environmental exposures to volatile organic compounds and biochemical liver tests: application of canonical correlation analysis.

    PubMed

    Liu, Jing; Drane, Wanzer; Liu, Xuefeng; Wu, Tiejian

    2009-02-01

    This study was to explore the relationships between personal exposure to 10 volatile organic compounds (VOCs) and biochemical liver tests with the application of canonical correlation analysis. Data from a subsample of the 1999-2000 National Health and Nutrition Examination Survey were used. Serum albumin, total bilirubin (TB), alanine aminotransferase (ALT), aspartate aminotransferase (AST), lactate dehydrogenase (LDH), alkaline phosphatase (ALP), and gamma-glutamyl transferase (GGT) served as the outcome variables. Personal exposures to benzene, chloroform, ethylbenzene, tetrachloroethene, toluene, trichloroethene, o-xylene, m-,p-xylene, 1,4-dichlorobenzene, and methyl tert-butyl ether (MTBE) were assessed through the use of passive exposure monitors worn by study participants. The first two canonical correlations were 0.3218 and 0.2575, suggesting a positive correlation mainly between the six VOCs (benzene, ethylbenzene, toluene, o-xylene, m-,p-xylene, and MTBE) and the three biochemical liver tests (albumin, ALP, and GGT) and a positive correlation mainly between the two VOCs (1,4-dichlorobenzene and tetrachloroethene) and the two biochemical liver tests (LDH and TB). Subsequent multiple linear regressions show that exposure to benzene, toluene, or MTBE was associated with serum albumin, while exposure to tetrachloroethene was associated with LDH and total bilirubin. In conclusion, exposure to certain VOCs as a group or individually may influence certain biochemical liver test results in the general population.

  11. aMMP-8 in correlation to caries and periodontal condition in adolescents-results of the epidemiologic LIFE child study.

    PubMed

    Schmidt, Jana; Guder, Ulrike; Kreuz, Markus; Löffler, Markus; Kiess, Wieland; Hirsch, Christian; Ziebolz, Dirk; Haak, Rainer

    2018-01-01

    The suitability of a chairside aMMP-8 test in determination of periodontal inflammation and caries in adolescents was assessed. Secondly, the influence of orthodontic treatment on aMMP-8 test result was analyzed. Within the LIFE Child study, 434 adolescents (10 to 18 years) were included. Clinical dental examinations comprised caries experience (DMF/T-Index), signs of periodontal inflammation (probing pocket depth, PPD; community periodontal index of treatment needs; CPITN) at six index teeth and oral hygiene (OH). Information about orthodontic appliances (OA) and socioeconomic status (SES) were obtained by validated questionnaires. Test's sensitivity and specificity to detect periodontal inflammation and carious lesions were evaluated. The influence of OA on the test result was analyzed (multivariate model). No associations between age, gender, SES or OH, and test outcome were found (p > 0.05). Positive test results correlated to periodontal findings (CPITN, mean PPD; p < 0.001). However, for the detection of ≥ 1 site(s) with PPD ≥ 4 mm, the test's sensitivity and specificity were found to be 61 and 69%, respectively. Multivariate analysis revealed a higher probability for a positive test result in cases of fixed OA (odds ratio 5.02, 95% confidence interval 1.90-13.19). The test had no diagnostic value considering carious lesions. The chairside aMMP-8 test does not reliably identify adolescents with periodontal inflammation. Positive test results were more frequent in case of OA. The chairside aMMP-8 test is no appropriate tool to screen children and adolescents neither for periodontal inflammation nor for carious lesions.

  12. Non-destructive testing techniques for the forensic engineering investigation of reinforced concrete buildings.

    PubMed

    Hobbs, Brian; Tchoketch Kebir, Mohamed

    2007-04-11

    This study describes in detail the results of a laboratory investigation where the compressive strength of 150mm side-length cubes was evaluated. Non-destructive testing (NDT) was carried out using ultrasonic pulse velocity (UPV) and impact rebound hammer (IRH) techniques to establish a correlation with the compressive strengths of compression tests. To adapt the Schmidt hammer apparatus and the ultrasonic pulse velocity tester to the type of concrete used in Algeria, concrete mix proportions that are recommended by the Algerian code were chosen. The resulting correlation curve for each test is obtained by changing the level of compaction, water/cement ratio and concrete age of specimens. Unlike other works, the research highlights the significant effect of formwork material on surface hardness of concrete where two different mould materials for specimens were used (plastic and wood). A combined method for the above two tests, reveals an improvement in the strength estimation of concrete. The latter shows more improvement by including the concrete density. The resulting calibration curves for strength estimation were compared with others from previous published literature.

  13. Short-term test-retest-reliability of conditioned pain modulation using the cold-heat-pain method in healthy subjects and its correlation to parameters of standardized quantitative sensory testing.

    PubMed

    Gehling, Julia; Mainka, Tina; Vollert, Jan; Pogatzki-Zahn, Esther M; Maier, Christoph; Enax-Krumova, Elena K

    2016-08-05

    Conditioned Pain Modulation (CPM) is often used to assess human descending pain inhibition. Nine different studies on the test-retest-reliability of different CPM paradigms have been published, but none of them has investigated the commonly used heat-cold-pain method. The results vary widely and therefore, reliability measures cannot be extrapolated from one CPM paradigm to another. Aim of the present study was to analyse the test-retest-reliability of the common heat-cold-pain method and its correlation to pain thresholds. We tested the short-term test-retest-reliability within 40 ± 19.9 h using a cold-water immersion (10 °C, left hand) as conditioning stimulus (CS) and heat pain (43-49 °C, pain intensity 60 ± 5 on the 101-point numeric rating scale, right forearm) as test stimulus (TS) in 25 healthy right-handed subjects (12females, 31.6 ± 14.1 years). The TS was applied 30s before (TSbefore), during (TSduring) and after (TSafter) the 60s CS. The difference between the pain ratings for TSbefore and TSduring represents the early CPM-effect, between TSbefore and TSafter the late CPM-effect. Quantitative sensory testing (QST, DFNS protocol) was performed on both sessions before the CPM assessment. paired t-tests, Intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD), Pearson's correlation, Bland-Altman analysis, significance level p < 0.05 with Bonferroni correction for multiple comparisons, when necessary. Pain ratings during CPM correlated significantly (ICC: 0.411…0.962) between both days, though ratings for TSafter were lower on day 2 (p < 0.005). The early (day 1: 16.7 ± 11.7; day 2: 19.5 ± 11.9; ICC: 0.618, SRD: 20.2) and late (day 1: 1.7 ± 9.2; day 2: 7.6 ± 11.5; ICC: 0.178, SRD: 27.0) CPM effect did not differ significantly between both days. Both early and late CPM-effects did not correlate with the pain thresholds. The short-term test-retest-reliability of the early CPM-effect using the heat-cold-pain method in healthy subjects achieved satisfying results in terms of the ICC. The SRD of the early CPM effect showed that an individual change of > 20 NRS can be attributed to a real change rather than chance. The late CPM-effect was weaker and not reliable.

  14. Correlation of Respirator Fit Measured on Human Subjects and a Static Advanced Headform

    PubMed Central

    Bergman, Michael S.; He, Xinjian; Joseph, Michael E.; Zhuang, Ziqing; Heimbuch, Brian K.; Shaffer, Ronald E.; Choe, Melanie; Wander, Joseph D.

    2015-01-01

    This study assessed the correlation of N95 filtering face-piece respirator (FFR) fit between a Static Advanced Headform (StAH) and 10 human test subjects. Quantitative fit evaluations were performed on test subjects who made three visits to the laboratory. On each visit, one fit evaluation was performed on eight different FFRs of various model/size variations. Additionally, subject breathing patterns were recorded. Each fit evaluation comprised three two-minute exercises: “Normal Breathing,” “Deep Breathing,” and again “Normal Breathing.” The overall test fit factors (FF) for human tests were recorded. The same respirator samples were later mounted on the StAH and the overall test manikin fit factors (MFF) were assessed utilizing the recorded human breathing patterns. Linear regression was performed on the mean log10-transformed FF and MFF values to assess the relationship between the values obtained from humans and the StAH. This is the first study to report a positive correlation of respirator fit between a headform and test subjects. The linear regression by respirator resulted in R2 = 0.95, indicating a strong linear correlation between FF and MFF. For all respirators the geometric mean (GM) FF values were consistently higher than those of the GM MFF. For 50% of respirators, GM FF and GM MFF values were significantly different between humans and the StAH. For data grouped by subject/respirator combinations, the linear regression resulted in R2 = 0.49. A weaker correlation (R2 = 0.11) was found using only data paired by subject/respirator combination where both the test subject and StAH had passed a real-time leak check before performing the fit evaluation. For six respirators, the difference in passing rates between the StAH and humans was < 20%, while two respirators showed a difference of 29% and 43%. For data by test subject, GM FF and GM MFF values were significantly different for 40% of the subjects. Overall, the advanced headform system has potential for assessing fit for some N95 FFR model/sizes. PMID:25265037

  15. How Strong and Weak Readers Perform on the Developmental Eye Movement Test (DEM): Norms for Latvian School-Aged Children

    ERIC Educational Resources Information Center

    Serdjukova, Jelena; Ekimane, Lasma; Valeinis, Janis; Skilters, Jurgis; Krumina, Gunta

    2017-01-01

    The aim of our study was to determine DEM test performance norms for school-aged children in Latvia, assess how DEM test results correlate with children's reading rates, compare test performance between strong and weak readers. A modified DEM test and a newly developed reading test were administered to 1487 children during a screening survey. Our…

  16. Distinguishing Depressive Pseudodementia from Alzheimer Disease: A Comparative Study of Hippocampal Volumetry and Cognitive Tests

    PubMed Central

    Sahin, Sevki; Okluoglu Önal, Tugba; Cinar, Nilgun; Bozdemir, Meral; Çubuk, Rahmi; Karsidag, Sibel

    2017-01-01

    Background and Aim Depressive pseudodementia (DPD) is a condition which may develop secondary to depression. The aim of this study was to contribute to the differential diagnosis between Alzheimer disease (AD) and DPD by comparing the neurocognitive tests and hippocampal volume. Materials and Methods Patients who met criteria of AD/DPD were enrolled in the study. All patients were assessed using the Wechsler Memory Scale (WMS), clock-drawing test, Stroop test, Benton Facial Recognition Test (BFRT), Boston Naming Test, Mini-Mental State Examination (MMSE), and Geriatric Depression Scale (GDS). Hippocampal volume was measured by importing the coronal T1-weighted magnetic resonance images to the Vitrea 2 workstation. Results A significant difference was found between the AD and DPD groups on the WMS test, clock-drawing test, Stroop test, Boston Naming Test, MMSE, GDS, and left hippocampal volume. A significant correlation between BFRT and bilateral hippocampal volumes was found in the AD group. No correlation was found among parameters in DPD patients. Conclusions Our results suggest that evaluation of facial recognition and left hippocampal volume may provide more reliable evidence for distinguishing DPD from AD. Further investigations combined with functional imaging techniques including more patients are needed. PMID:28868066

  17. Correlation of MRI Visual Scales with Neuropsychological Profile in Mild Cognitive Impairment of Parkinson's Disease.

    PubMed

    Vasconcellos, Luiz Felipe; Pereira, João Santos; Adachi, Marcelo; Greca, Denise; Cruz, Manuela; Malak, Ana Lara; Charchat-Fichman, Helenice; Spitz, Mariana

    2017-01-01

    Few studies have evaluated magnetic resonance imaging (MRI) visual scales in Parkinson's disease-Mild Cognitive Impairment (PD-MCI). We selected 79 PD patients and 92 controls (CO) to perform neurologic and neuropsychological evaluation. Brain MRI was performed to evaluate the following scales: Global Cortical Atrophy (GCA), Fazekas, and medial temporal atrophy (MTA). The analysis revealed that both PD groups (amnestic and nonamnestic) showed worse performance on several tests when compared to CO. Memory, executive function, and attention impairment were more severe in amnestic PD-MCI group. Overall analysis of frequency of MRI visual scales by MCI subtype did not reveal any statistically significant result. Statistically significant inverse correlation was observed between GCA scale and Mini-Mental Status Examination (MMSE), Montreal Cognitive Assessment (MoCA), semantic verbal fluency, Stroop test, figure memory test, trail making test (TMT) B, and Rey Auditory Verbal Learning Test (RAVLT). The MTA scale correlated with Stroop test and Fazekas scale with figure memory test, digit span, and Stroop test according to the subgroup evaluated. Visual scales by MRI in MCI should be evaluated by cognitive domain and might be more useful in more severely impaired MCI or dementia patients.

  18. Surface accuracy measurement sensor test on a 50-meter antenna surface model

    NASA Technical Reports Server (NTRS)

    Spiers, R. B.; Burcher, E. E.; Stump, C. W.; Saunders, C. G.; Brooks, G. F.

    1984-01-01

    The Surface Accuracy Measurement Sensor (SAMS) is a telescope with a focal plane photo electric detector that senses the lateral position of light source targets in its field of view. After extensive laboratory testing the engineering breadboard sensor system was installed and tested on a 30 degree segment of a 50-meter diameter, mesh surface, antenna model. Test results correlated well with the laboratory tests and indicated accuracies of approximately 0.59 arc seconds at 21 meters range. Test results are presented and recommendations given for sensor improvements.

  19. Polymer matrix and graphite fiber interface study

    NASA Technical Reports Server (NTRS)

    Adams, D. F.; Zimmerman, R. S.; Odom, E. M.

    1985-01-01

    Hercules AS4 graphite fiber, unsized, or with EPON 828, PVA, or polysulfone sizing, was combined with three different polymer matrices. These included Hercules 3501-6 epoxy, Hercules 4001 bismaleimide, and Hexcel F155 rubber toughened epoxy. Unidirectional composites in all twelve combinations were fabricated and tested in transverse tension and axial compression. Quasi-isotropic laminates were tested in axial tension and compression, flexure, interlaminar shear, and tensile impact. All tests were conducted at both room temperature, dry and elevated temperature, and wet conditions. Single fiber pullout testing was also performed. Extensive scanning electron microphotographs of fracture surfaces are included, along with photographs of single fiber pullout failures. Analytical/experimental correlations are presented, based on the results of a finite element micromechanics analysis. Correlations between matrix type, fiber sizing, hygrothermal environment, and loading mode are presented. Results indicate that the various composite properties were only moderately influenced by the fiber sizings utilized.

  20. Analysis of flight test transition and turbulent heating data. Part 1: Boundary layer transition results

    NASA Technical Reports Server (NTRS)

    Martellucci, A.; Maguire, B. L.; Neff, R. S.

    1972-01-01

    The objective of the study was to provide a detailed post flight evaluation of ballistic vehicle flight test boundary layer transition data. A total of fifty-five vehicles were selected for analysis. These vehicles were chosen from a data sampling of roughly two hundred flights and the criteria for vehicle selection is delineated herein. The results of the analysis indicate that frustum transition of re-entry vehicles appears to be nose tip dominated. Frustum related parameters and materials apparently have a second order effect on transition. This implies that local viscous parameters on the frustum should not correlate flight test transition data, and in fact they do not. Specific parameters relative to the nose tip have been identified as the apparent dominant factors that characterize the transition phenomena and a correlation of flight test data is presented.

  1. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters

    PubMed Central

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-01

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis. PMID:26805819

  2. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    PubMed

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  3. Evaporation heat transfer of carbon dioxide at low temperature inside a horizontal smooth tube

    NASA Astrophysics Data System (ADS)

    Yoon, Jung-In; Son, Chang-Hyo; Jung, Suk-Ho; Jeon, Min-Ju; Yang, Dong-Il

    2017-05-01

    In this paper, the evaporation heat transfer coefficient of carbon dioxide at low temperature of -30 to -20 °C in a horizontal smooth tube was investigated experimentally. The test devices consist of mass flowmeter, pre-heater, magnetic gear pump, test section (evaporator), condenser and liquid receiver. Test section is made of cooper tube. Inner and outer diameter of the test section is 8 and 9.52 mm, respectively. The experiment is conducted at mass fluxes from 100 to 300 kg/m2 s, saturation temperature from -30 to -20 °C. The main results are summarized as follows: In case that the mass flux of carbon dioxide is 100 kg/m2 s, the evaporation heat transfer coefficient is almost constant regardless of vapor quality. In case of 200 and 300 kg/m2 s, the evaporation heat transfer coefficient increases steadily with increasing vapor quality. For the same mass flux, the evaporation heat transfer coefficient increases as the evaporation temperature of the refrigerant decreases. In comparison of heat transfer correlations with the experimental result, the evaporation heat transfer correlations do not predict them exactly. Therefore, more accurate heat transfer correlation than the previous one is required.

  4. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players

    PubMed Central

    Daneshfar, Amin; Gahreman, Daniel E.; Koozehchian, Majid S.; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T.

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team (n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA (r = −0.57, p ≤ 0.05) and RSM (r = −0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test (r = −0.64, p ≤ 0.01) and in RSM test (r = −0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT (r = 0.58, p ≤ 0.01), WT (r = 0.62, p ≤ 0.01), and TT (r = 0.65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM (r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players. PMID:29670536

  5. Multi Directional Repeated Sprint Is a Valid and Reliable Test for Assessment of Junior Handball Players.

    PubMed

    Daneshfar, Amin; Gahreman, Daniel E; Koozehchian, Majid S; Amani Shalamzari, Sadegh; Hassanzadeh Sablouei, Mozhgan; Rosemann, Thomas; Knechtle, Beat; Nikolaidis, Pantelis T

    2018-01-01

    The aim of the present study was to examine the validity and reliability of a 10 × (6 × 5 m) multi-directional repeated sprint ability test (RSM) in elite young team handball (TH) players. Participants were members of the Iranian national team ( n = 20, age 16.4 ± 0.7 years, weight 82.5 ± 5.5 kg, height 184.8 ± 4.6 cm, body fat 15.4 ± 4.3%). The validity of RSM was tested against a 10 × (15 + 15 m) repeated sprint ability test (RSA), Yo-Yo Intermittent Recovery test Level 1 (Yo-Yo IR1), squat jump (SJ) and countermovement jump (CMJ). To test the reliability of RSM, the participants repeated the testing sessions of RSM and RSA 1 week later. Both RSA and RSM tests showed good to excellent reliability of the total time (TT), best time (BT), and weakest time (WT). The results of the correlation analysis showed significant inverse correlations between maximum aerobic capacity and TT in RSA ( r = -0.57, p ≤ 0.05) and RSM ( r = -0.76, p ≤ 0.01). There was also a significant inverse correlation between maximum aerobic capacity with fatigue index (FI) in RSA test ( r = -0.64, p ≤ 0.01) and in RSM test ( r = -0.53, p ≤ 0.05). BT, WT, and TT of RSA was largely-to-very largely correlated with BT ( r = 0.58, p ≤ 0.01), WT ( r = 0.62, p ≤ 0.01), and TT ( r = 0 .65, p ≤ 0.01) of RSM. BT in RSM was also correlated with FI in RSM ( r = 0.88, p ≤ 0.01). In conclusion, based on the findings of the current study, the recently developed RSM test is a valid and reliable test and should be utilized for assessment of repeated sprint ability in handball players.

  6. Investigation of the relations between neat resin and advanced composite mechanical properties. Volume 1: Results

    NASA Technical Reports Server (NTRS)

    Zimmerman, R. S.; Adams, D. F.; Walrath, D. E.

    1984-01-01

    A detailed evaluation of one untoughened epoxy baseline resin and three toughened epoxy resin systems was performed. The Hercules 3502, 2220-1, and 2220-3, and Ciba-Geigy Fibredux 914 resin systems were supplied in the uncured state by NASA-Langley and cast into thin flat specimens and round dogbone specimens. Tensile and torsional shear measurements were performed at three temperatures and two moisture conditions. Coefficients of thermal expansion and moisture expansion were also measured. Extensive scanning electron microscopic examination of fracture surfaces was performed, to permit the correlation of observed failure modes with the environmental conditions under which the various specimens were tested. A micromechanics analysis was used to predict the unidirectional composite response under the various test conditions, using the neat resin experimental results as the required input data. Mechanical and physical test results, the scanning electron microscope observations, and the analytical predictions were then correlated.

  7. Visual field examination method using virtual reality glasses compared with the Humphrey perimeter.

    PubMed

    Tsapakis, Stylianos; Papaconstantinou, Dimitrios; Diagourtas, Andreas; Droutsas, Konstantinos; Andreanos, Konstantinos; Moschos, Marilita M; Brouzas, Dimitrios

    2017-01-01

    To present a visual field examination method using virtual reality glasses and evaluate the reliability of the method by comparing the results with those of the Humphrey perimeter. Virtual reality glasses, a smartphone with a 6 inch display, and software that implements a fast-threshold 3 dB step staircase algorithm for the central 24° of visual field (52 points) were used to test 20 eyes of 10 patients, who were tested in a random and consecutive order as they appeared in our glaucoma department. The results were compared with those obtained from the same patients using the Humphrey perimeter. High correlation coefficient ( r =0.808, P <0.0001) was found between the virtual reality visual field test and the Humphrey perimeter visual field. Visual field examination results using virtual reality glasses have a high correlation with the Humphrey perimeter allowing the method to be suitable for probable clinical use.

  8. Rapid Methods for Biochemical Testing of Anaerobic Bacteria

    PubMed Central

    Schreckenberger, Paul C.; Blazevic, Donna J.

    1974-01-01

    Rapid biochemical tests for nitrate, indole, gelatin, starch, esculin, and o-nitrophenyl-β-D-galactopyranoside were performed on 112 strains of anaerobic bacteria. All tests were incubated under aerobic conditions, and results were recorded within 4 h. The tests for nitrate, indole, and starch showed a 95% or greater correlation when compared to the standard biochemical tests. Tests for esculin and gelatin showed an agreement of 86 and 77%, respectively. PathoTec test strips for nitrate, indole, esculin, o-nitrophenyl-β-D-galactopyranoside, Voges-Proskauer, and urease were also tested and showed encouraging results. PMID:4613268

  9. Analytical and experimental investigation of a 1/8-scale dynamic model of the shuttle orbiter. Volume 2: Technical report

    NASA Technical Reports Server (NTRS)

    Mason, P. W.; Harris, H. G.; Zalesak, J.; Bernstein, M.

    1974-01-01

    The methods and procedures used in the analysis and testing of the scale model are reported together with the correlation of the analytical and experimental results. The model, the NASTRAN finite element analysis, and results are discussed. Tests and analytical investigations are also reported.

  10. Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

    PubMed Central

    Wang, Shijun; Yao, Jianhua; Liu, Jiamin; Petrick, Nicholas; Van Uitert, Robert L.; Periaswamy, Senthil; Summers, Ronald M.

    2009-01-01

    Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice—Once supine and once prone—to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined by the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27±52.97 to 14.98 mm±11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline. PMID:20095272

  11. Registration of prone and supine CT colonography scans using correlation optimized warping and canonical correlation analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang Shijun; Yao Jianhua; Liu Jiamin

    Purpose: In computed tomographic colonography (CTC), a patient will be scanned twice--Once supine and once prone--to improve the sensitivity for polyp detection. To assist radiologists in CTC reading, in this paper we propose an automated method for colon registration from supine and prone CTC scans. Methods: We propose a new colon centerline registration method for prone and supine CTC scans using correlation optimized warping (COW) and canonical correlation analysis (CCA) based on the anatomical structure of the colon. Four anatomical salient points on the colon are first automatically distinguished. Then correlation optimized warping is applied to the segments defined bymore » the anatomical landmarks to improve the global registration based on local correlation of segments. The COW method was modified by embedding canonical correlation analysis to allow multiple features along the colon centerline to be used in our implementation. Results: We tested the COW algorithm on a CTC data set of 39 patients with 39 polyps (19 training and 20 test cases) to verify the effectiveness of the proposed COW registration method. Experimental results on the test set show that the COW method significantly reduces the average estimation error in a polyp location between supine and prone scans by 67.6%, from 46.27{+-}52.97 to 14.98 mm{+-}11.41 mm, compared to the normalized distance along the colon centerline algorithm (p<0.01). Conclusions: The proposed COW algorithm is more accurate for the colon centerline registration compared to the normalized distance along the colon centerline method and the dynamic time warping method. Comparison results showed that the feature combination of z-coordinate and curvature achieved lowest registration error compared to the other feature combinations used by COW. The proposed method is tolerant to centerline errors because anatomical landmarks help prevent the propagation of errors across the entire colon centerline.« less

  12. Grayscale Optical Correlator Workbench

    NASA Technical Reports Server (NTRS)

    Hanan, Jay; Zhou, Hanying; Chao, Tien-Hsin

    2006-01-01

    Grayscale Optical Correlator Workbench (GOCWB) is a computer program for use in automatic target recognition (ATR). GOCWB performs ATR with an accurate simulation of a hardware grayscale optical correlator (GOC). This simulation is performed to test filters that are created in GOCWB. Thus, GOCWB can be used as a stand-alone ATR software tool or in combination with GOC hardware for building (target training), testing, and optimization of filters. The software is divided into three main parts, denoted filter, testing, and training. The training part is used for assembling training images as input to a filter. The filter part is used for combining training images into a filter and optimizing that filter. The testing part is used for testing new filters and for general simulation of GOC output. The current version of GOCWB relies on the mathematical software tools from MATLAB binaries for performing matrix operations and fast Fourier transforms. Optimization of filters is based on an algorithm, known as OT-MACH, in which variables specified by the user are parameterized and the best filter is selected on the basis of an average result for correct identification of targets in multiple test images.

  13. Differences in cognitive ability and hippocampal volume between Alzheimer's disease, amnestic mild cognitive impairment, and healthy control groups, and their correlation.

    PubMed

    Choi, Mi-Hyun; Kim, Hyung-Sik; Gim, Seon-Young; Kim, Woo-Ram; Mun, Kyung-Ryul; Tack, Gye-Rae; Lee, Bongsoo; Choi, Young Chil; Kim, Hyun-Jun; Hong, Seung Hwa; Lim, Dae-Woon; Chung, Soon-Cheol

    2016-05-04

    The study investigated differences in cognitive ability and hippocampal volume between groups of patients with Alzheimer's disease (AD) and amnestic mild cognitive impairment (aMCI), and healthy control (HC) subjects, and explored the relationship between cognitive ability and hippocampal volume. Among the sub-tests of Korean version of the Consortium to Establish a Registry for Alzheimer's Disease (CERAD-K), the Boston naming test score decreased in the order HC, aMCI, and AD. The hippocampal volumes of subjects with AD and aMCI were relatively smaller than those of HC individuals. There were strongly positive correlations between hippocampal volume and the scores for the Boston naming test. Discriminant analysis identified the Boston naming test as having the highest level of discrimination among the variables used to differentiate the three groups (89.9%). In conclusion, the Boston naming test accurately differentiated the three groups and was correlated with hippocampal volume. These results will be helpful for choosing an accurate and economically feasible test method that efficiently differentiates the three groups. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. The use of piezocone tests for high-resolution stratigraphy of Quaternary sediment sequences in the Brazilian coast.

    PubMed

    de Mio, Giuliano; Giacheti, Heraldo L

    2007-03-01

    Correlations between mapping units of costal sedimentary basin and interpretation of piezocone test results are presented and discussed based on examples from Caravelas strandplain, (State of Bahia), Paranaguá (State of Paraná) and Guarujá bays (State of São Paulo), Brazil. Recognizing that the sedimentary environment was mainly controlled by sea level fluctuations led to the interpretation of transgressive and regressive sedimentary sequences, which is in a good agreement with the sea level fluctuation curves currently accepted for these regions. The interpretation of piezocone test results shows that the sedimentary sequences of Caravelas and Guarujá sites are similar and they have a good correlation to the sea level fluctuation curve accepted for Salvador region, State of Bahia. On the other hand, the piezocone test results from Paranaguá site indicate a different sedimentary sequence from the previous ones, relating to the sea level fluctuation curve accepted for Paranaguá region. The results show the high applicability of piezocone testing for stratigraphical logging and suggest that it is possible to integrate it with other current techniques used for paleo-environmental studies in Brazil, in accordance with recent approaches used in international research on the subject.

  15. Lessons Learned During Instrument Testing for the Thermal Infrared Sensor (TIRS)

    NASA Technical Reports Server (NTRS)

    Peabody, Hume L.; Otero, Veronica; Neuberger, David

    2013-01-01

    The Themal InfraRed Sensor (TIRS) instrument, set to launch on the Landsat Data Continuity Mission in 2013, features a passively cooled telescope and IR detectors which are actively cooled by a two stage cryocooler. In order to proceed to the instrument level test campaign, at least one full functional test was required, necessitating a thermal vacuum test to sufficiently cool the detectors and demonstrate performance. This was fairly unique in that this test occurred before the Pre Environmental Review, but yielded significant knowledge gains before the planned instrument level test. During the pre-PER test, numerous discrepancies were found between the model and the actual hardware, which were revealed by poor correlation between model predictions and test data. With the inclusion of pseudo-balance points, the test also provided an opportunity to perform a pre-correlation to test data prior to the instrument level test campaign. Various lessons were learned during this test related to modeling and design of both the flight hardware and the Ground Support Equipment and test setup. The lessons learned in the pre-PER test resulted in a better test setup for the nstrument level test and the completion of the final instrument model correlation in a shorter period of time. Upon completion of the correlation, the flight predictions were generated including the full suite of off-nominal cases, including some new cases defined by the spacecraft. For some of these ·new cases, some components now revealed limit exceedances, in particular for a portion of the hardware that could not be tested due to its size and chamber limitations.. Further lessons were learned during the completion of flight predictions. With a correlated detalled instrument model, significant efforts were made to generate a reduced model suitable for observatory level analyses. This proved a major effort both to generate an appropriate network as well as to convert to the final model to the required format and yielded additional lessons learned. In spite of all the challenges encountered by TIRS, the instrument was successfully delivered to the spacecraft and will soon be tested at observatory level in preparation for a successful mission launch.

  16. Basal measures of insulin sensitivity and insulin secretion and simplified glucose tolerance tests in dogs.

    PubMed

    Verkest, K R; Fleeman, L M; Rand, J S; Morton, J M

    2010-10-01

    There is need for simple, inexpensive measures of glucose tolerance, insulin sensitivity, and insulin secretion in dogs. The aim of this study was to estimate the closeness of correlation between fasting and dynamic measures of insulin sensitivity and insulin secretion, the precision of fasting measures, and the agreement between results of standard and simplified glucose tolerance tests in dogs. A retrospective descriptive study using 6 naturally occurring obese and 6 lean dogs was conducted. Data from frequently sampled intravenous glucose tolerance tests (FSIGTTs) in 6 obese and 6 lean client-owned dogs were used to calculate HOMA, QUICKI, fasting glucose and insulin concentrations. Fasting measures of insulin sensitivity and secretion were compared with MINMOD analysis of FSIGTTs using Pearson correlation coefficients, and they were evaluated for precision by the discriminant ratio. Simplified sampling protocols were compared with standard FSIGTTs using Lin's concordance correlation coefficients, limits of agreement, and Pearson correlation coefficients. All fasting measures except fasting plasma glucose concentration were moderately correlated with MINMOD-estimated insulin sensitivity (|r| = 0.62-0.80; P < 0.03), and those that combined fasting insulin and glucose were moderately closely correlated with MINMOD-estimated insulin secretion (r = 0.60-0.79; P < 0.04). HOMA calculated using the nonlinear formulae had the closest estimated correlation (r = 0.77 and 0.74) and the best discrimination for insulin sensitivity and insulin secretion (discriminant ratio 4.4 and 3.4, respectively). Simplified sampling protocols with half as many samples collected over 3 h had close agreement with the full sampling protocol. Fasting measures and simplified intravenous glucose tolerance tests reflect insulin sensitivity and insulin secretion derived from frequently sampled glucose tolerance tests with MINMOD analysis in dogs. Copyright 2010 Elsevier Inc. All rights reserved.

  17. Test of GET Electronics for the CHIMERA and FARCOS multi-detectors

    NASA Astrophysics Data System (ADS)

    De Luca, S.; Acosta, L.; Auditore, L.; Boiano, C.; Cardella, G.; Castoldi, A.; D'Andrea, M.; De Filippo, E.; Dell'Aquila, D.; Fichera, F.; Gnoffo, B.; Guazzoni, C.; Lanzalone, G.; Lombardo, I.; Martorana, N. S.; Minniti, T.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Saccà, G.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, M.

    2017-11-01

    In this paper we present the results of the tests on the new digital electronics GET (General Electronics for Tpc), which will be used for the readout of the CsI(Tl) detectors of CHIMERA (Charged Heavy Ion Mass and Energy Resolving Array) and for the new correlator FARCOS (Femtoscope ARray for COrrelations and Spectroscopy). The new electronics allows us to digitize the full waveform of the signals produced by the detector. Among its features it is worth noticing the compactness and low power consumption (5W for 256 channels). Tests have been performed with pulsers, radioactive sources and ion beams. With such electronics very good results in energy resolution and isotope separation of the detected fragments were obtained, by using both hardware and software filters.

  18. Statistical EMC: A new dimension electromagnetic compatibility of digital electronic systems

    NASA Astrophysics Data System (ADS)

    Tsaliovich, Anatoly

    Electromagnetic compatibility compliance test results are used as a database for addressing three classes of electromagnetic-compatibility (EMC) related problems: statistical EMC profiles of digital electronic systems, the effect of equipment-under-test (EUT) parameters on the electromagnetic emission characteristics, and EMC measurement specifics. Open area test site (OATS) and absorber line shielded room (AR) results are compared for equipment-under-test highest radiated emissions. The suggested statistical evaluation methodology can be utilized to correlate the results of different EMC test techniques, characterize the EMC performance of electronic systems and components, and develop recommendations for electronic product optimal EMC design.

  19. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    PubMed

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  20. Learning Machine Learning: A Case Study

    ERIC Educational Resources Information Center

    Lavesson, N.

    2010-01-01

    This correspondence reports on a case study conducted in the Master's-level Machine Learning (ML) course at Blekinge Institute of Technology, Sweden. The students participated in a self-assessment test and a diagnostic test of prerequisite subjects, and their results on these tests are correlated with their achievement of the course's learning…

  1. Numerical CFD Simulation and Test Correlation in a Flight Project Environment

    NASA Technical Reports Server (NTRS)

    Gupta, K. K.; Lung, S. F.; Ibrahim, A. H.

    2015-01-01

    This paper presents detailed description of a novel CFD procedure and comparison of its solution results to that obtained by other available CFD codes as well as actual flight and wind tunnel test data pertaining to the GIII aircraft, currently undergoing flight testing at AFRC.

  2. The Relation between Self-Selected Study Processes and Test Performance.

    ERIC Educational Resources Information Center

    Nist, Sherrie L.; And Others

    1991-01-01

    A correlational study examined the relationship between test performance and four study processes (encoding, word meaning, organizing, and executive control). Results with 123 college freshmen trained to use study strategies suggest that executive control is related to test performance and that trained subjects select a variety of strategies…

  3. Development and psychometric evaluation of an information literacy self-efficacy survey and an information literacy knowledge test*

    PubMed Central

    Tepe, Rodger; Tepe, Chabha

    2015-01-01

    Objective To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. Methods In this test–retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. Results The IL self-efficacy survey demonstrated good reliability (test–retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test–retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). Conclusions This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments. PMID:25517736

  4. Prevalence and Correlates of School Bullying Victimization in Xi'an, China.

    PubMed

    Zhu, Yuhong; Chan, Ko Ling

    2015-01-01

    This study used the data from a representative sample to estimate the prevalence of child bullying victimization in Xi'an, China. Data on social demographic information and the experiences of different types of bullying victimization were collected from a randomly selected sample with 3,175 middle school students aged 15-17 years by self-administrated questionnaires. t Test, χ2 test, and multiple logistic regression analyses were used to test group differences and examine the correlates of bullying victimization. Results show that 54.9% and 44.6% of Chinese children have been bullied in a lifetime and in the preceding year, respectively. Correlates for direct and relational bullying victimization includes male participants, father's lower education level, father's unemployment, having one or more siblings, smoking, depression, borderline personality trait, posttraumatic stress disorder, and from rural schools. Overall, the prevalence of child bullying victimization in China is substantial. The multiple correlates suggest prevention and intervention of bullying victimization in a holistic and comprehensive way.

  5. Validity and reliability of wii fit balance board for the assessment of balance of healthy young adults and the elderly.

    PubMed

    Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen

    2013-10-01

    [Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86-0.99) for the elderly people and positive correlations (r = 0.58-0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability.

  6. [Cross-cultural adaptation and validation of the Health and Taste Attitude Scale (HTAS) in Portuguese].

    PubMed

    Koritar, Priscila; Philippi, Sonia Tucunduva; Alvarenga, Marle dos Santos; Santos, Bernardo dos

    2014-08-01

    The scope of this study was to show the cross-cultural adaptation and validation of the Health and Taste Attitude Scale in Portuguese. The methodology included translation of the scale; evaluation of conceptual, operational and item-based equivalence by 14 experts and 51 female undergraduates; semantic equivalence and measurement assessment by 12 bilingual women by the paired t-test, the Pearson correlation coefficient and the coefficient intraclass correlation; internal consistency and test-retest reliability by Cronbach's alpha and intraclass correlation coefficient, respectively, after application on 216 female undergraduates; assessment of discriminant and concurrent validity via the t-test and Spearman's correlation coefficient, respectively, in addition to Confirmatory Factor and Exploratory Factor Analysis. The scale was considered adequate and easily understood by the experts and university students and presented good internal consistency and reliability (µ 0.86, ICC 0.84). The results show that the scale is valid and can be used in studies with women to better understand attitudes related to taste.

  7. Validity of wearable activity monitors for tracking steps and estimating energy expenditure during a graded maximal treadmill test.

    PubMed

    Kendall, Bradley; Bellovary, Bryanne; Gothe, Neha P

    2018-06-04

    The purpose of this study was to assess the accuracy of energy expenditure (EE) estimation and step tracking abilities of six activity monitors (AMs) in relation to indirect calorimetry and hand counted steps and assess the accuracy of the AMs between high and low fit individuals in order to assess the impact of exercise intensity. Fifty participants wore the Basis watch, Fitbit Flex, Polar FT7, Jawbone, Omron pedometer, and Actigraph during a maximal graded treadmill test. Correlations, intra-class correlations, and t-tests determined accuracy and agreement between AMs and criterions. The results indicate that the Omron, Fitbit, and Actigraph were accurate for measuring steps while the Basis and Jawbone significantly underestimated steps. All AMs were significantly correlated with indirect calorimetry, however, no devices showed agreement (p < .05). When comparing low and high fit groups, correlations between AMs and indirect calorimetry improved for the low fit group, suggesting AMs may be better at measuring EE at lower intensity exercise.

  8. Antifungal Susceptibility Testing of Fluconazole by Flow Cytometry Correlates with Clinical Outcome

    PubMed Central

    Wenisch, Christoph; Moore, Caroline B.; Krause, Robert; Presterl, Elisabeth; Pichna, Peter; Denning, David W.

    2001-01-01

    Susceptibility testing of fungi by flow cytometry (also called fluorescence-activated cell sorting [FACS]) using vital staining with FUN-1 showed a good correlation with the standard M27-A procedure for assessing MICs. In this study we determined MICs for blood culture isolates from patients with candidemia by NCCLS M27-A and FACS methods and correlated the clinical outcome of these patients with in vitro antifungal resistance test results. A total of 24 patients with candidemia for whom one or more blood cultures were positive for a Candida sp. were included. Susceptibility testing was performed by NCCLS M27-A and FACS methods. The correlation of MICs (NCCLS M27-A and FACS) and clinical outcome was calculated. In 83% of the cases, the MICs of fluconazole determined by FACS were within 1 dilution of the MICs determined by the NCCLS M27-A method. For proposed susceptibility breakpoints, there was 100% agreement between the M27-A and FACS methods. In the FACS assay, a fluconazole MIC of <1 μg/ml was associated with cure (P < 0.001) whereas an MIC of ≥1 μg/ml was associated with death (P < 0.001). The M27-A-derived fluconazole MICs did not correlate with outcome (P = 1 and P = 0.133). PMID:11427554

  9. Correlation between Self-Citation and Impact Factor in Iranian English Medical Journals in WoS and ISC: A Comparative Approach

    PubMed Central

    GHAZI MIRSAEID, Seyed Javad; MOTAMEDI, Nadia; RAMEZAN GHORBANI, Nahid

    2015-01-01

    Background: In this study, the impact of self-citation (Journal and Author) on impact factor of Iranian English Medical journals in two international citation databases, Web of Science (WoS) and Islamic world science citation center (ISC), were compared by citation analysis. Methods: Twelve journals in WoS and 26 journals in ISC databases indexed between the years (2006–2009) were selected and compared. For comparison of self-citation rate in two databases, we used Wilcoxon and Mann-whitney tests. We used Pearson test for correlation of self-citation and IF in WoS, and the Spearman’s correlation coefficient for the ISC database. Covariance analysis was used for comparison of two correlation tests. P. value was 0.05 in all of tests. Results: There was no significant difference between self-citation rates in two databases (P>0.05). Findings also showed no significant difference between the correlation of Journal self-citation and impact factor in two databases (P=0.526) however, there was significant difference between the author’s self-citation and impact factor in these databases (P<0.001). Conclusion: The impact of Author’s self-citation in the Impact Factor of WoS was higher than the ISC. PMID:26587498

  10. Assembling a Computerized Adaptive Testing Item Pool as a Set of Linear Tests

    ERIC Educational Resources Information Center

    van der Linden, Wim J.; Ariel, Adelaide; Veldkamp, Bernard P.

    2006-01-01

    Test-item writing efforts typically results in item pools with an undesirable correlational structure between the content attributes of the items and their statistical information. If such pools are used in computerized adaptive testing (CAT), the algorithm may be forced to select items with less than optimal information, that violate the content…

  11. The Role of Teachers in Reducing/Increasing Listening Comprehension Test Anxiety: A Case of Iranian EFL Learners

    ERIC Educational Resources Information Center

    Atasheneh, Naser; Izadi, Ahmad

    2012-01-01

    Three components have been introduced for foreign language learning anxiety in the literature: Test anxiety, fear of negative evaluation and communication apprehension. This study teases out the first of the three components with special focus on listening comprehension test to investigate the correlation between listening test results and foreign…

  12. Psychometric characteristics of Clinical Reasoning Problems (CRPs) and its correlation with routine multiple choice question (MCQ) in Cardiology department.

    PubMed

    Derakhshandeh, Zahra; Amini, Mitra; Kojuri, Javad; Dehbozorgian, Marziyeh

    2018-01-01

    Clinical reasoning is one of the most important skills in the process of training a medical student to become an efficient physician. Assessment of the reasoning skills in a medical school program is important to direct students' learning. One of the tests for measuring the clinical reasoning ability is Clinical Reasoning Problems (CRPs). The major aim of this study is to measure psychometric qualities of CRPs and define correlation between this test and routine MCQ in cardiology department of Shiraz medical school. This study was a descriptive study conducted on total cardiology residents of Shiraz Medical School. The study population consists of 40 residents in 2014. The routine CRPs and the MCQ tests was designed based on similar objectives and were carried out simultaneously. Reliability, item difficulty, item discrimination, and correlation between each item and the total score of CRPs were all measured by Excel and SPSS software for checking psycometeric CRPs test. Furthermore, we calculated the correlation between CRPs test and MCQ test. The mean differences of CRPs test score between residents' academic year [second, third and fourth year] were also evaluated by Analysis of variances test (One Way ANOVA) using SPSS software (version 20)(α=0.05). The mean and standard deviation of score in CRPs was 10.19 ±3.39 out of 20; in MCQ, it was 13.15±3.81 out of 20. Item difficulty was in the range of 0.27-0.72; item discrimination was 0.30-0.75 with question No.3 being the exception (that was 0.24). The correlation between each item and the total score of CRP was 0.26-0.87; the correlation between CRPs test and MCQ test was 0.68 (p<0.001). The reliability of the CRPs was 0.72 as calculated by using Cronbach's alpha. The mean score of CRPs was different among residents based on their academic year and this difference was statistically significant (p<0.001). The results of this present investigation revealed that CRPs could be reliable test for measuring clinical reasoning in residents. It can be included in cardiology residency assessment programs.

  13. Evaluation of Aution Max AX-4030 and 9UB Uriflet, 10PA Aution Sticks urine dipsticks in the automated urine test strip analysis.

    PubMed

    Rota, Cristina; Biondi, Marco; Trenti, Tommaso

    2011-09-26

    Aution Max AX-4030, a test strip analyzer recently introduced to the market, represents an upgrade of the Aution Max AX-4280 widely employed for urinalysis. This new instrument model can allocate two different test strips at the same time. In the present study the two instruments have been compared together with the usage of Uriflet 9UB and the recently produced Aution Sticks 10PA urine strips, the latter presenting an additional test area for the measurement of urinary creatinine. Imprecision and correlation between instruments and strips have been evaluated for chemical-physical parameters. Accuracy was evaluated for protein, glucose and creatinine by comparing the semi-quantitative results to those obtained by quantitative methods. The well-known interference effect of high ascorbic acid levels on urine glucose test strip determination was evaluated, ascorbic acid influence was also evaluated on protein and creatinine determination. The two instruments have demonstrated comparable performances: precision and correlation between instruments and strips, evaluated for chemical-physical parameters, were always good. Furthermore, accuracy was always very good: results of protein and glucose semi-quantitative measurements resulted to be highly correlated with those obtained by quantitative methods. Moreover, the semi-quantitative measurements of creatinine, employing Aution Sticks 10PA urine strips, were highly comparable with quantitative results. 10PA urine strips are eligible for urine creatinine determination with the possibility of correcting urinalysis results for urinary creatinine concentration, whenever necessary and calculating the protein creatinine ratio. Further studies should be carried out to evaluate effectiveness and appropriateness of the usage of creatinine semi-quantitative analysis.

  14. The role of chronotype, gender, test anxiety, and conscientiousness in academic achievement of high school students.

    PubMed

    Rahafar, Arash; Maghsudloo, Mahdis; Farhangnia, Sajedeh; Vollmer, Christian; Randler, Christoph

    2016-01-01

    Previous findings have demonstrated that chronotype (morningness/intermediate/eveningness) is correlated with cognitive functions, that is, people show higher mental performance when they do a test at their preferred time of day. Empirical studies found a relationship between morningness and higher learning achievement at school and university. However, only a few of them controlled for other moderating and mediating variables. In this study, we included chronotype, gender, conscientiousness and test anxiety in a structural equation model (SEM) with grade point average (GPA) as academic achievement outcome. Participants were 158 high school students and results revealed that boys and girls differed in GPA and test anxiety significantly, with girls reporting better grades and higher test anxiety. Moreover, there was a positive correlation between conscientiousness and GPA (r = 0.17) and morningness (r = 0.29), respectively, and a negative correlation between conscientiousness and test anxiety (r = -0.22). The SEM demonstrated that gender was the strongest predictor of academic achievement. Lower test anxiety predicted higher GPA in girls but not in boys. Additionally, chronotype as moderator revealed a significant association between gender and GPA for evening types and intermediate types, while intermediate types showed a significant relationship between test anxiety and GPA. Our results suggest that gender is an essential predictor of academic achievement even stronger than low or absent test anxiety. Future studies are needed to explore how gender and chronotype act together in a longitudinal panel design and how chronotype is mediated by conscientiousness in the prediction of academic achievement.

  15. The Leukocyte Esterase Strip Test has Practical Value for Diagnosing Periprosthetic Joint Infection After Total Knee Arthroplasty: A Multicenter Study.

    PubMed

    Koh, In J; Han, Seung B; In, Yong; Oh, Kwang J; Lee, Dae H; Kim, Tae K

    2017-11-01

    Leukocyte esterase (LE) was recently reported to be an accurate marker for diagnosing periprosthetic joint infection (PJI) as defined by the Musculoskeletal Infection Society (MSIS) criteria. However, the diagnostic value of the LE test for PJI after total knee arthroplasty (TKA), the reliability of the subjective visual interpretation of the LE test, and the correlation between the LE test results and the current MSIS criteria remain unclear. This study prospectively enrolled 60 patients undergoing revision TKA for either PJI or aseptic failure. Serological marker, synovial fluid, and histological analyses were performed in all cases. The PJI group comprised 38 cases that met the MSIS criteria and the other 22 cases formed the aseptic group. All the LE tests were interpreted using both visual judgment and automated colorimetric reader. When "++" results were considered to indicate a positive PJI, the sensitivity, specificity, positive and negative predictive value, and diagnostic accuracy were 84, 100, 100, 79, and 90%, respectively. The visual interpretation agreed with the automated colorimetric reader in 90% of cases (Cronbach α = 0.894). The grade of the LE test was strongly correlated with the synovial white blood cell count (ρ = 0.695) and polymorphonuclear leukocyte percentage (ρ = 0.638) and moderately correlated with the serum C-reactive protein and erythrocyte sedimentation rate. The LE test has high diagnostic value for diagnosing PJI after TKA. Subjective visual interpretation of the LE test was reliable and valid for the current battery of PJI diagnostic tests according to the MSIS criteria. Copyright © 2017. Published by Elsevier Inc.

  16. Comparison of the South African Spondaic and CID W-1 wordlists for measuring speech recognition threshold

    PubMed Central

    Soer, Maggi; Pottas, Lidia

    2015-01-01

    Background The home language of most audiologists in South Africa is either English or Afrikaans, whereas most South Africans speak an African language as their home language. The use of an English wordlist, the South African Spondaic (SAS) wordlist, which is familiar to the English Second Language (ESL) population, was developed by the author for testing the speech recognition threshold (SRT) of ESL speakers. Objectives The aim of this study was to compare the pure-tone average (PTA)/SRT correlation results of ESL participants when using the SAS wordlist (list A) and the CID W-1 spondaic wordlist (list B – less familiar; list C – more familiar CID W-1 words). Method A mixed-group correlational, quantitative design was adopted. PTA and SRT measurements were compared for lists A, B and C for 101 (197 ears) ESL participants with normal hearing or a minimal hearing loss (<26 dBHL; mean age 33.3). Results The Pearson correlation analysis revealed a strong PTA/SRT correlation when using list A (right 0.65; left 0.58) and list C (right 0.63; left 0.56). The use of list B revealed weak correlations (right 0.30; left 0.32). Paired sample t-tests indicated a statistically significantly stronger PTA/SRT correlation when list A was used, rather than list B or list C, at a 95% level of confidence. Conclusions The use of the SAS wordlist yielded a stronger PTA/SRT correlation than the use of the CID W-1 wordlist, when performing SRT testing on South African ESL speakers with normal hearing, or minimal hearing loss (<26 dBHL). PMID:26304218

  17. Effectiveness of Quantitative Real Time PCR in Long-Term Follow-up of Chronic Myeloid Leukemia Patients.

    PubMed

    Savasoglu, Kaan; Payzin, Kadriye Bahriye; Ozdemirkiran, Fusun; Berber, Belgin

    2015-08-01

    To determine the use of the Quantitative Real Time PCR (RQ-PCR) assay follow-up with Chronic Myeloid Leukemia (CML) patients. Cross-sectional observational. Izmir Ataturk Education and Research Hospital, Izmir, Turkey, from 2009 to 2013. Cytogenetic, FISH, RQ-PCR test results from 177 CMLpatients' materials selected between 2009 - 2013 years was set up for comparison analysis. Statistical analysis was performed to compare between FISH, karyotype and RQ-PCR results of the patients. Karyotyping and FISH specificity and sensitivity rates determined by ROC analysis compared with RQ-PCR results. Chi-square test was used to compare test failure rates. Sensitivity and specificity values were determined for karyotyping 17.6 - 98% (p=0.118, p > 0.05) and for FISH 22.5 - 96% (p=0.064, p > 0.05) respectively. FISH sensitivity was slightly higher than karyotyping but there was calculated a strong correlation between them (p < 0.001). RQ-PCR test failure rate did not correlate with other two tests (p > 0.05); however, karyotyping and FISH test failure rate was statistically significant (p < 0.001). Besides, the situation needed for karyotype analysis, RQ-PCR assay can be used alone in the follow-up of CMLdisease.

  18. Predicting future protection of respirator users: Statistical approaches and practical implications.

    PubMed

    Hu, Chengcheng; Harber, Philip; Su, Jing

    2016-01-01

    The purpose of this article is to describe a statistical approach for predicting a respirator user's fit factor in the future based upon results from initial tests. A statistical prediction model was developed based upon joint distribution of multiple fit factor measurements over time obtained from linear mixed effect models. The model accounts for within-subject correlation as well as short-term (within one day) and longer-term variability. As an example of applying this approach, model parameters were estimated from a research study in which volunteers were trained by three different modalities to use one of two types of respirators. They underwent two quantitative fit tests at the initial session and two on the same day approximately six months later. The fitted models demonstrated correlation and gave the estimated distribution of future fit test results conditional on past results for an individual worker. This approach can be applied to establishing a criterion value for passing an initial fit test to provide reasonable likelihood that a worker will be adequately protected in the future; and to optimizing the repeat fit factor test intervals individually for each user for cost-effective testing.

  19. Techniques for hot structures testing

    NASA Technical Reports Server (NTRS)

    Deangelis, V. Michael; Fields, Roger A.

    1990-01-01

    Hot structures testing have been going on since the early 1960's beginning with the Mach 6, X-15 airplane. Early hot structures test programs at NASA-Ames-Dryden focused on operational testing required to support the X-15 flight test program, and early hot structures research projects focused on developing lab test techniques to simulate flight thermal profiles. More recent efforts involved numerous large and small hot structures test programs that served to develop test methods and measurement techniques to provide data that promoted the correlation of test data with results from analytical codes. In Nov. 1988 a workshop was sponsored that focused on the correlation of hot structures test data with analysis. Limited material is drawn from the workshop and a more formal documentation is provided of topics that focus on hot structures test techniques used at NASA-Ames-Dryden. Topics covered include the data acquisition and control of testing, the quartz lamp heater systems, current strain and temperature sensors, and hot structures test techniques used to simulate the flight thermal environment in the lab.

  20. Voluntary explicit versus involuntary conceptual memory are associated with dissociable fMRI responses in hippocampus, amygdala, and parietal cortex for emotional and neutral word pairs.

    PubMed

    Ramponi, Cristina; Barnard, Philip J; Kherif, Ferath; Henson, Richard N

    2011-08-01

    Although functional neuroimaging studies have supported the distinction between explicit and implicit forms of memory, few have matched explicit and implicit tests closely, and most of these tested perceptual rather than conceptual implicit memory. We compared event-related fMRI responses during an intentional test, in which a group of participants used a cue word to recall its associate from a prior study phase, with those in an incidental test, in which a different group of participants used the same cue to produce the first associate that came to mind. Both semantic relative to phonemic processing at study, and emotional relative to neutral word pairs, increased target completions in the intentional test, but not in the incidental test, suggesting that behavioral performance in the incidental test was not contaminated by voluntary explicit retrieval. We isolated the neural correlates of successful retrieval by contrasting fMRI responses to studied versus unstudied cues for which the equivalent "target" associate was produced. By comparing the difference in this repetition-related contrast across the intentional and incidental tests, we could identify the correlates of voluntary explicit retrieval. This contrast revealed increased bilateral hippocampal responses in the intentional test, but decreased hippocampal responses in the incidental test. A similar pattern in the bilateral amygdale was further modulated by the emotionality of the word pairs, although surprisingly only in the incidental test. Parietal regions, however, showed increased repetition-related responses in both tests. These results suggest that the neural correlates of successful voluntary explicit memory differ in directionality, even if not in location, from the neural correlates of successful involuntary implicit (or explicit) memory, even when the incidental test taps conceptual processes.

  1. Assessing the treatment effects in apraxia of speech: introduction and evaluation of the Modified Diadochokinesis Test.

    PubMed

    Hurkmans, Joost; Jonkers, Roel; Boonstra, Anne M; Stewart, Roy E; Reinders-Messelink, Heleen A

    2012-01-01

    The number of reliable and valid instruments to measure the effects of therapy in apraxia of speech (AoS) is limited. To evaluate the newly developed Modified Diadochokinesis Test (MDT), which is a task to assess the effects of rate and rhythm therapies for AoS in a multiple baseline across behaviours design. The consistency, accuracy and fluency of speech of 24 adults with AoS and 12 unaffected speakers matched for age, gender and educational level were assessed using the MDT. The reliability and validity of the instrument were considered and outcomes compared with those obtained with existing tests. The results revealed that MDT had a strong internal consistency. Scores were influenced by syllable structure complexity, while distinctive features of articulation had no measurable effect. The test-retest and intra- and inter-rater reliabilities were shown to be adequate, and the discriminant validity was good. For convergent validity different outcomes were found: apart from one correlation, the scores on tests assessing functional communication and AoS correlated significantly with the MDT outcome measures. The spontaneous speech phonology measure of the Aachen Aphasia Test (AAT) correlated significantly with the MDT outcome measures, but no correlations were found for the repetition subtest and the spontaneous speech articulation/prosody measure of the AAT. The study shows that the MDT has adequate psychometric properties, implying that it can be used to measure changes in speech motor control during treatment for apraxia of speech. The results demonstrate the validity and utility of the instrument as a supplement to speech tasks in assessing speech improvement aimed at the level of planning and programming of speech. © 2012 Royal College of Speech and Language Therapists.

  2. Relationship Between Abdominal Symptoms and Fructose Ingestion in Children with Chronic Abdominal Pain.

    PubMed

    Hammer, Veronika; Hammer, Katharina; Memaran, Nima; Huber, Wolf-Dietrich; Hammer, Karin; Hammer, Johann

    2018-05-01

    Limited valid data are available regarding the association of fructose-induced symptoms, fructose malabsorption, and clinical symptoms. To develop a questionnaire for valid symptom assessment before and during a carbohydrate breath test and to correlate symptoms with fructose breath test results in children/adolescents with functional abdominal pain. A Likert-type questionnaire assessing symptoms considered relevant for hydrogen breath test in children was developed and underwent initial validation. Fructose malabsorption was determined by increased breath hydrogen in 82 pediatric patients with functional abdominal pain disorders; fructose-induced symptoms were quantified by symptom score ≥2 and relevant symptom increase over baseline. The results were correlated with clinical symptoms. The time course of symptoms during the breath test was assessed. The questionnaire exhibited good psychometric properties in a standardized assessment of the severity of carbohydrate-related symptoms. A total of 40 % (n = 33) had malabsorption; symptoms were induced in 38 % (n = 31), but only 46 % (n = 15) with malabsorption were symptomatic. There was no significant correlation between fructose malabsorption and fructose-induced symptoms. Clinical symptoms correlated with symptoms evoked during the breath test (p < 0.001, r 2  = 0.21) but not with malabsorption (NS). Malabsorbers did not differ from non-malabsorbers in terms of symptoms during breath test. Symptomatic patients had significantly higher pain and flatulence scores over the 9-h observation period (p < 0.01) than did nonsymptomatic patients; the meteorism score was higher after 90 min. Fructose-induced symptoms but not fructose malabsorption are related to increased abdominal symptoms and have distinct timing patterns.

  3. The relation of hippocampal subfield volumes to verbal episodic memory measured by the California Verbal Learning Test II in healthy adults.

    PubMed

    Aslaksen, Per M; Bystad, Martin K; Ørbo, Marte C; Vangberg, Torgil R

    2018-06-08

    Total hippocampal volume has previously been shown to correlate with performance on tests for verbal episodic memory. However, there are sparse evidence on how hippocampal subfield volumes are related to verbal episodic memory in healthy adults. The present study investigated the association between volumes of separate hippocampal subfields and verbal episodic memory performance in healthy volunteers. Forty-seven participants (31 females) between 20 to 71 years age underwent testing with the California Verbal Learning Test II (CVLT II), and the Wechsler Abbreviated Scale of Intelligence (WASI) to obtain an estimate of cognitive functioning. T1-weighted MR images were obtained after cognitive testing, and volumetric estimates adjusted for age and estimated total intracranial volume were calculated in the FreeSurfer 6.0 software suite for cerebral -and hippocampal structures. The sample performed within the statistical normal range on both CVLT II and WASI. Significant correlations adjusted for multiple testing were found between CVLT II subtests of total learning, free immediate recall and free delayed recall and volumes of the left Cornu Ammonis (CA) 1-4 subfields. There were no significant correlations between right hippocampal subfields and CVLT II performance, and no significant correlation between WASI results and hippocampal subfields. The present results suggest that better verbal episodic memory measured by the CVLT II is associated with relative larger volumes of specific left CA hippocampal subfields in healthy adults. Due to the small sample size and large age-span of the participants, the present findings are preliminary and should be confirmed in larger samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  4. Large-Scale Test of Dynamic Correlation Processors: Implications for Correlation-Based Seismic Pipelines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dodge, D. A.; Harris, D. B.

    Correlation detectors are of considerable interest to the seismic monitoring communities because they offer reduced detection thresholds and combine detection, location and identification functions into a single operation. They appear to be ideal for applications requiring screening of frequent repeating events. However, questions remain about how broadly empirical correlation methods are applicable. We describe the effectiveness of banks of correlation detectors in a system that combines traditional power detectors with correlation detectors in terms of efficiency, which we define to be the fraction of events detected by the correlators. This paper elaborates and extends the concept of a dynamic correlationmore » detection framework – a system which autonomously creates correlation detectors from event waveforms detected by power detectors; and reports observed performance on a network of arrays in terms of efficiency. We performed a large scale test of dynamic correlation processors on an 11 terabyte global dataset using 25 arrays in the single frequency band 1-3 Hz. The system found over 3.2 million unique signals and produced 459,747 screened detections. A very satisfying result is that, on average, efficiency grows with time and, after nearly 16 years of operation, exceeds 47% for events observed over all distance ranges and approaches 70% for near regional and 90% for local events. This observation suggests that future pipeline architectures should make extensive use of correlation detectors, principally for decluttering observations of local and near-regional events. Our results also suggest that future operations based on correlation detection will require commodity large-scale computing infrastructure, since the numbers of correlators in an autonomous system can grow into the hundreds of thousands.« less

  5. Large-Scale Test of Dynamic Correlation Processors: Implications for Correlation-Based Seismic Pipelines

    DOE PAGES

    Dodge, D. A.; Harris, D. B.

    2016-03-15

    Correlation detectors are of considerable interest to the seismic monitoring communities because they offer reduced detection thresholds and combine detection, location and identification functions into a single operation. They appear to be ideal for applications requiring screening of frequent repeating events. However, questions remain about how broadly empirical correlation methods are applicable. We describe the effectiveness of banks of correlation detectors in a system that combines traditional power detectors with correlation detectors in terms of efficiency, which we define to be the fraction of events detected by the correlators. This paper elaborates and extends the concept of a dynamic correlationmore » detection framework – a system which autonomously creates correlation detectors from event waveforms detected by power detectors; and reports observed performance on a network of arrays in terms of efficiency. We performed a large scale test of dynamic correlation processors on an 11 terabyte global dataset using 25 arrays in the single frequency band 1-3 Hz. The system found over 3.2 million unique signals and produced 459,747 screened detections. A very satisfying result is that, on average, efficiency grows with time and, after nearly 16 years of operation, exceeds 47% for events observed over all distance ranges and approaches 70% for near regional and 90% for local events. This observation suggests that future pipeline architectures should make extensive use of correlation detectors, principally for decluttering observations of local and near-regional events. Our results also suggest that future operations based on correlation detection will require commodity large-scale computing infrastructure, since the numbers of correlators in an autonomous system can grow into the hundreds of thousands.« less

  6. Cognitive Testing in People at Increased Risk of Dementia Using a Smartphone App: The iVitality Proof-of-Principle Study

    PubMed Central

    Wijsman, Liselotte Willemijn; Cachucho, Ricardo; Hoevenaar-Blom, Marieke Peternella; Mooijaart, Simon Pieter; Richard, Edo

    2017-01-01

    Background Smartphone-assisted technologies potentially provide the opportunity for large-scale, long-term, repeated monitoring of cognitive functioning at home. Objective The aim of this proof-of-principle study was to evaluate the feasibility and validity of performing cognitive tests in people at increased risk of dementia using smartphone-based technology during a 6 months follow-up period. Methods We used the smartphone-based app iVitality to evaluate five cognitive tests based on conventional neuropsychological tests (Memory-Word, Trail Making, Stroop, Reaction Time, and Letter-N-Back) in healthy adults. Feasibility was tested by studying adherence of all participants to perform smartphone-based cognitive tests. Validity was studied by assessing the correlation between conventional neuropsychological tests and smartphone-based cognitive tests and by studying the effect of repeated testing. Results We included 151 participants (mean age in years=57.3, standard deviation=5.3). Mean adherence to assigned smartphone tests during 6 months was 60% (SD 24.7). There was moderate correlation between the firstly made smartphone-based test and the conventional test for the Stroop test and the Trail Making test with Spearman ρ=.3-.5 (P<.001). Correlation increased for both tests when comparing the conventional test with the mean score of all attempts a participant had made, with the highest correlation for Stroop panel 3 (ρ=.62, P<.001). Performance on the Stroop and the Trail Making tests improved over time suggesting a learning effect, but the scores on the Letter-N-back, the Memory-Word, and the Reaction Time tests remained stable. Conclusions Repeated smartphone-assisted cognitive testing is feasible with reasonable adherence and moderate relative validity for the Stroop and the Trail Making tests compared with conventional neuropsychological tests. Smartphone-based cognitive testing seems promising for large-scale data-collection in population studies. PMID:28546139

  7. Improved maximum average correlation height filter with adaptive log base selection for object recognition

    NASA Astrophysics Data System (ADS)

    Tehsin, Sara; Rehman, Saad; Awan, Ahmad B.; Chaudry, Qaiser; Abbas, Muhammad; Young, Rupert; Asif, Afia

    2016-04-01

    Sensitivity to the variations in the reference image is a major concern when recognizing target objects. A combinational framework of correlation filters and logarithmic transformation has been previously reported to resolve this issue alongside catering for scale and rotation changes of the object in the presence of distortion and noise. In this paper, we have extended the work to include the influence of different logarithmic bases on the resultant correlation plane. The meaningful changes in correlation parameters along with contraction/expansion in the correlation plane peak have been identified under different scenarios. Based on our research, we propose some specific log bases to be used in logarithmically transformed correlation filters for achieving suitable tolerance to different variations. The study is based upon testing a range of logarithmic bases for different situations and finding an optimal logarithmic base for each particular set of distortions. Our results show improved correlation and target detection accuracies.

  8. The impact of surface area, volume, curvature, and Lennard-Jones potential to solvation modeling.

    PubMed

    Nguyen, Duc D; Wei, Guo-Wei

    2017-01-05

    This article explores the impact of surface area, volume, curvature, and Lennard-Jones (LJ) potential on solvation free energy predictions. Rigidity surfaces are utilized to generate robust analytical expressions for maximum, minimum, mean, and Gaussian curvatures of solvent-solute interfaces, and define a generalized Poisson-Boltzmann (GPB) equation with a smooth dielectric profile. Extensive correlation analysis is performed to examine the linear dependence of surface area, surface enclosed volume, maximum curvature, minimum curvature, mean curvature, and Gaussian curvature for solvation modeling. It is found that surface area and surfaces enclosed volumes are highly correlated to each other's, and poorly correlated to various curvatures for six test sets of molecules. Different curvatures are weakly correlated to each other for six test sets of molecules, but are strongly correlated to each other within each test set of molecules. Based on correlation analysis, we construct twenty six nontrivial nonpolar solvation models. Our numerical results reveal that the LJ potential plays a vital role in nonpolar solvation modeling, especially for molecules involving strong van der Waals interactions. It is found that curvatures are at least as important as surface area or surface enclosed volume in nonpolar solvation modeling. In conjugation with the GPB model, various curvature-based nonpolar solvation models are shown to offer some of the best solvation free energy predictions for a wide range of test sets. For example, root mean square errors from a model constituting surface area, volume, mean curvature, and LJ potential are less than 0.42 kcal/mol for all test sets. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. Intelligence and Complexity of the Averaged Evoked Potential: An Attentional Theory.

    ERIC Educational Resources Information Center

    Bates, Tim; And Others

    1995-01-01

    A study measuring average evoked potentials in 21 college students finds that intelligence test scores correlate significantly with the difference between string length in attended and nonattended conditions, a finding that suggests that previous inconsistencies in reporting string length-intelligence correlations may have resulted from confound…

  10. Inferential Procedures for Correlation Coefficients Corrected for Attenuation.

    ERIC Educational Resources Information Center

    Hakstian, A. Ralph; And Others

    1988-01-01

    A model and computation procedure based on classical test score theory are presented for determination of a correlation coefficient corrected for attenuation due to unreliability. Delta and Monte Carlo method applications are discussed. A power analysis revealed no serious loss in efficiency resulting from correction for attentuation. (TJH)

  11. Some Personality Correlates of Logical Reasoning Ability.

    ERIC Educational Resources Information Center

    Ross, G. Robert, Jr.; Fletcher, Harold J.

    Four-hundred and nine students (grades 8, 10, 12 and 14) were given logical syllogism problems of the form "If p...then q" along with tests of dogmatism and intolerance of ambiguity. Aptitude scores were also obtained. Major results indicated that expressed dogmatism and intolerance of ambiguity were negatively correlated with syllogistic…

  12. Quadriceps femoris spasticity in children with cerebral palsy: measurement with the pendulum test and relationship with gait abnormalities.

    PubMed

    Szopa, Andrzej; Domagalska-Szopa, Małgorzata; Kidoń, Zenon; Syczewska, Małgorzata

    2014-12-16

    Development of a reliable and objective test of spasticity is important for assessment and treatment of children with cerebral palsy. The pendulum test has been reported to yield reliable measurements of spasticity and to be sensitive to variations in spasticity in these children. However, the relationship between the pendulum test scores and other objective measures of spasticity has not been studied. The present study aimed to assess the effectiveness of an accelerometer-based pendulum test as a measurement of spasticity in CP, and to explore the correlation between the measurements of this test and the global index of deviation from normal gait in in children with cerebral palsy. We studied thirty-six children with cerebral palsy, including 18 with spastic hemiplegia and 18 with spastic diplegia, and a group of 18 typically-developing children. Knee extensor spasticity was assessed bilaterally using the accelerometer-based pendulum test and three-dimensional gait analysis. The Gillette Gait Index was calculated from the results of the gait analysis. The data from the accelerometer-based pendulum test could be used to distinguish between able-bodied children and children with cerebral palsy. Additionally, two of the measurements, first swing excursion and relaxation index, could be used to differentiate the degree of knee extensor spasticity in the children with cerebral palsy. Only a few moderate correlations were found between the Gillette Gait Index and the pendulum test data. This study demonstrates that the pendulum test can be used to discriminate between typically developing children and children with CP, as well as between various degrees of spasticity, such as spastic hemiplegia and spastic diplegia, in the knee extensor muscle of children with CP. Deviations from normal gait in children with CP were not correlated with the results of the pendulum test.

  13. Correlational selection does not explain the evolution of a behavioural syndrome.

    PubMed

    Han, C S; Brooks, R C

    2013-10-01

    Correlated suites of behaviours, or behavioural syndromes, appear to be widespread, and yet few studies have explored how they arise and are maintained. One possibility holds that correlational selection can generate and maintain behavioural syndrome if certain behavioural combinations enjoy greater fitness than other combinations. Here we test this correlational selection hypothesis by comparing behavioural syndrome structure with a multivariate fitness surface based on reproductive success of male water striders. We measured the structure of a behavioural syndrome including dispersal ability, exploration behaviour, latency to remount and sex recognition sensitivity in males. We then measured the relationship between these behaviours and mating success in a range of sex ratio environments. Despite the presence of some significant correlational selection, behavioural syndrome structure was not associated with correlational selection on behaviours. Although we cannot conclusively reject the correlational selection hypothesis, our evidence suggests that correlational selection and resulting linkage disequilibrium might not be responsible for maintaining the strong correlations between behaviours. Instead, we suggest alternative ways in which this behavioural syndrome may have arisen and outline the need for physiological and quantitative genetic tests of these suggestions. © 2013 The Authors. Journal of Evolutionary Biology © 2013 European Society For Evolutionary Biology.

  14. Study of occupational stress among railway engine pilots

    PubMed Central

    Kumar, Devesh; Singh, Jai Vir; Kharwar, Poonam S.

    2011-01-01

    Background: Traffic volume and speed is going to be increased in Indian Railways successively, leading to higher stress in staff connected with train operations. The jobs of railway engine pilots come under the category of high-strain jobs, necessitating a need to conduct multicentric study to unfold the factors associated with occupational stress and organizational strategies. Materials and Methods: Present study covered 185 railway engine pilots and office clerks working in various railway zones by incidental method. Occupational Stress Index (OSI) test developed by Srivastva and Singh, questionnaire of specific stressors constructed by authors and laboratory test battery for psychological screening of high-speed train pilots were used as tools. Results: Means of OSI and all the 12 occupational stressors of railway engine pilots were found significantly higher to that of office clerks. Means of OSI and occupational stressors of goods train pilots were significantly higher in comparison to high-speed train pilots and passenger train pilots. Study revealed positive correlation of speed perception and complex reaction time tests and negative correlation of other constituent tests of laboratory test battery to OSI test. Highest subgroup of stressor observedwas role overload followed by role conflict. Conclusions: These findings provide a prima facie evidence of higher occupational stress among railway engine pilots because of identified specific stressors prevalent in their job and explore the possible intervention strategies for its reduction. Significant correlation is noticed between OSI and laboratory test results, indicating its relevant utility in preliminary psychological screening. PMID:21808497

  15. A PILOT STUDY OF CORE STABILITY AND ATHLETIC PERFORMANCE: IS THERE A RELATIONSHIP?

    PubMed Central

    Sharrock, Chris; Cropper, Jarrod; Mostad, Joel; Johnson, Matt

    2011-01-01

    Study Design: Correlation study Objectives: To objectively evaluate the relationship between core stability and athletic performance measures in male and female collegiate athletes. Background: The relationship between core stability and athletic performance has yet to be quantified in the available literature. The current literature does not demonstrate whether or not core strength relates to functional performance. Questions remain regarding the most important components of core stability, the role of sport specificity, and the measurement of core stability in relation to athletic performance. Methods: A sample of 35 volunteer student athletes from Asbury College (NAIA Division II) provided informed consent. Participants performed a series of five tests: double leg lowering (core stability test), the forty yard dash, the T-test, vertical jump, and a medicine ball throw. Participants performed three trials of each test in a randomized order. Results: Correlations between the core stability test and each of the other four performance tests were determined using a General Linear Model. Medicine ball throw negatively correlated to the core stability test (r –0.389, p=0.023). Participants that performed better on the core stability test had a stronger negative correlation to the medicine ball throw (r =–0.527). Gender was the most strongly correlated variable to core strength, males with a mean measurement of double leg lowering of 47.43 degrees compared to females having a mean of 54.75 degrees. Conclusions: There appears to be a link between a core stability test and athletic performance tests; however, more research is needed to provide a definitive answer on the nature of this relationship. Ideally, specific performance tests will be able to better define and to examine relationships to core stability. Future studies should also seek to determine if there are specific sub-categories of core stability which are most important to allow for optimal training and performance for individual sports. PMID:21713228

  16. Status of the Correlation Process of the V-HAB Simulation with Ground Tests and ISS Telemetry Data

    NASA Technical Reports Server (NTRS)

    Ploetner, P.; Roth, C.; Zhukov, A.; Czupalla, M.; Anderson, M.; Ewert, M.

    2013-01-01

    The Virtual Habitat (V-HAB) is a dynamic Life Support System (LSS) simulation, created for investigation of future human spaceflight missions. It provides the capability to optimize LSS during early design phases. The focal point of the paper is the correlation and validation of V-HAB against ground test and flight data. In order to utilize V-HAB to design an Environmental Control and Life Support System (ECLSS) it is important to know the accuracy of simulations, strengths and weaknesses. Therefore, simulations of real systems are essential. The modeling of the International Space Station (ISS) ECLSS in terms of single technologies as well as an integrated system and correlation against ground and flight test data is described. The results of the simulations make it possible to prove the approach taken by V-HAB.

  17. Determination of resilient modulus values for typical plastic soils in Wisconsin.

    DOT National Transportation Integrated Search

    2011-09-01

    "The objectives of this research are to establish a resilient modulus test results database and to develop : correlations for estimating the resilient modulus of Wisconsin fine-grained soils from basic soil properties. A : laboratory testing program ...

  18. Bone quality assessment for total hip arthroplasty with intraoperative trabecular torque measurements.

    PubMed

    Klotz, Matthias C M; Beckmann, Nicholas A; Bitsch, Rudi G; Seebach, Elisabeth; Reiner, Tobias; Jäger, Sebastian

    2014-11-13

    In cases of poor bone quality, intraoperative torque measurement might be an alternative to preoperative dual-energy X-ray absorptiometry (DXA) to assess bone quality in total hip arthroplasty (THA). Trabecular peak torque measurement was applied in 14 paired fresh frozen human femurs. Here, a 6.5 × 23 mm wingblade was inserted into the proximal femur without harming the lateral cortical bone. Further tests of the proximal femur also evaluated bone strength (DXA, micro-computed tomography (μCT), monoaxial compression test), and the results were compared to the trabecular torque measurement. Student's t-test was used to compare the values of the groups. Pearson product-moment was applied to correlate the values of the peak torque measurement with the bone strength measured by DXA, μCT, and monoaxial compression test. In the femoral head, the mean trabecular peak torque was 4.38 ± 1.86 Nm. These values showed a strong correlation with the values of the DXA, the μCT, and the biomechanical load test (Pearson's product-moment: DXA: 0.86, μCT-BMD: 0.80, load test: 0.85). Furthermore, the torque measurement showed a more pronounced correlation with the biomechanical load test compared to the DXA. The use of this method provides highly diagnostic information about bone quality. Since the approach was adjusted for THA, no harm of the lateral bone stock will result from this measurement during surgery. The results of this initial study employing small sample sizes indicate that this new method is as sensitive as DXA in predicting bone quality and may function as an intraoperative alternative to DXA in THA. Nevertheless, before this method will turn into clinical use, more research and clinical trials are necessary.

  19. Fired Cartridge Case Identification Using Optical Images and the Congruent Matching Cells (CMC) Method

    PubMed Central

    Tong, Mingsi; Song, John; Chu, Wei; Thompson, Robert M

    2014-01-01

    The Congruent Matching Cells (CMC) method for ballistics identification was invented at the National Institute of Standards and Technology (NIST). The CMC method is based on the correlation of pairs of small correlation cells instead of the correlation of entire images. Four identification parameters – TCCF, Tθ, Tx and Ty are proposed for identifying correlated cell pairs originating from the same firearm. The correlation conclusion (matching or non-matching) is determined by whether the number of CMC is ≥ 6. This method has been previously validated using a set of 780 pair-wise 3D topography images. However, most ballistic images stored in current local and national databases are in an optical intensity (grayscale) format. As a result, the reliability of applying the CMC method on optical intensity images is an important issue. In this paper, optical intensity images of breech face impressions captured on the same set of 40 cartridge cases are correlated and analyzed for the validation test of CMC method using optical images. This includes correlations of 63 pairs of matching images and 717 pairs of non-matching images under top ring lighting. Tests of the method do not produce any false identification (false positive) or false exclusion (false negative) results, which support the CMC method and the proposed identification criterion, C = 6, for firearm breech face identifications using optical intensity images. PMID:26601045

  20. Fired Cartridge Case Identification Using Optical Images and the Congruent Matching Cells (CMC) Method.

    PubMed

    Tong, Mingsi; Song, John; Chu, Wei; Thompson, Robert M

    2014-01-01

    The Congruent Matching Cells (CMC) method for ballistics identification was invented at the National Institute of Standards and Technology (NIST). The CMC method is based on the correlation of pairs of small correlation cells instead of the correlation of entire images. Four identification parameters - T CCF, T θ, T x and T y are proposed for identifying correlated cell pairs originating from the same firearm. The correlation conclusion (matching or non-matching) is determined by whether the number of CMC is ≥ 6. This method has been previously validated using a set of 780 pair-wise 3D topography images. However, most ballistic images stored in current local and national databases are in an optical intensity (grayscale) format. As a result, the reliability of applying the CMC method on optical intensity images is an important issue. In this paper, optical intensity images of breech face impressions captured on the same set of 40 cartridge cases are correlated and analyzed for the validation test of CMC method using optical images. This includes correlations of 63 pairs of matching images and 717 pairs of non-matching images under top ring lighting. Tests of the method do not produce any false identification (false positive) or false exclusion (false negative) results, which support the CMC method and the proposed identification criterion, C = 6, for firearm breech face identifications using optical intensity images.

  1. A Priori Analyses of Three Subgrid-Scale Models for One-Parameter Families of Filters

    NASA Technical Reports Server (NTRS)

    Pruett, C. David; Adams, Nikolaus A.

    1998-01-01

    The decay of isotropic turbulence a compressible flow is examined by direct numerical simulation (DNS). A priori analyses of the DNS data are then performed to evaluate three subgrid-scale (SGS) models for large-eddy simulation (LES): a generalized Smagorinsky model (M1), a stress-similarity model (M2), and a gradient model (M3). The models exploit one-parameter second- or fourth-order filters of Pade type, which permit the cutoff wavenumber k(sub c) to be tuned independently of the grid increment (delta)x. The modeled (M) and exact (E) SGS-stresses are compared component-wise by correlation coefficients of the form C(E,M) computed over the entire three-dimensional fields. In general, M1 correlates poorly against exact stresses (C < 0.2), M3 correlates moderately well (C approx. 0.6), and M2 correlates remarkably well (0.8 < C < 1.0). Specifically, correlations C(E, M2) are high provided the grid and test filters are of the same order. Moreover, the highest correlations (C approx.= 1.0) result whenever the grid and test filters are identical (in both order and cutoff). Finally, present results reveal the exact SGS stresses obtained by grid filters of differing orders to be only moderately well correlated. Thus, in LES the model should not be specified independently of the filter.

  2. Validation of the Vanderbilt Holistic Face Processing Test.

    PubMed

    Wang, Chao-Chih; Ross, David A; Gauthier, Isabel; Richler, Jennifer J

    2016-01-01

    The Vanderbilt Holistic Face Processing Test (VHPT-F) is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014). In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the same construct as the composite task, which is group-based measure at the center of the large literature on holistic face processing. In Experiment 1, we found a significant correlation between holistic processing measured in the VHPT-F and the composite task. Although this correlation was small, it was comparable to the correlation between holistic processing measured in the composite task with the same faces, but different target parts (top or bottom), which represents a reasonable upper limit for correlations between the composite task and another measure of holistic processing. These results confirm the validity of the VHPT-F by demonstrating shared variance with another measure of holistic processing based on the same operational definition. These results were replicated in Experiment 2, but only when the demographic profile of our sample matched that of Experiment 1.

  3. Validation of the Vanderbilt Holistic Face Processing Test

    PubMed Central

    Wang, Chao-Chih; Ross, David A.; Gauthier, Isabel; Richler, Jennifer J.

    2016-01-01

    The Vanderbilt Holistic Face Processing Test (VHPT-F) is a new measure of holistic face processing with better psychometric properties relative to prior measures developed for group studies (Richler et al., 2014). In fields where psychologists study individual differences, validation studies are commonplace and the concurrent validity of a new measure is established by comparing it to an older measure with established validity. We follow this approach and test whether the VHPT-F measures the same construct as the composite task, which is group-based measure at the center of the large literature on holistic face processing. In Experiment 1, we found a significant correlation between holistic processing measured in the VHPT-F and the composite task. Although this correlation was small, it was comparable to the correlation between holistic processing measured in the composite task with the same faces, but different target parts (top or bottom), which represents a reasonable upper limit for correlations between the composite task and another measure of holistic processing. These results confirm the validity of the VHPT-F by demonstrating shared variance with another measure of holistic processing based on the same operational definition. These results were replicated in Experiment 2, but only when the demographic profile of our sample matched that of Experiment 1. PMID:27933014

  4. The practical approach to the evaluation of methods used to determine the disintegration time of orally disintegrating tablets (ODTs).

    PubMed

    Brniak, Witold; Jachowicz, Renata; Pelka, Przemyslaw

    2015-09-01

    Even that orodispersible tablets (ODTs) have been successfully used in therapy for more than 20 years, there is still no compendial method of their disintegration time evaluation other than the pharmacopoeial disintegration test conducted in 800-900 mL of distilled water. Therefore, several alternative tests more relevant to in vivo conditions were described by different researchers. The aim of this study was to compare these methods and correlate them with in vivo results. Six series of ODTs were prepared by direct compression. Their mechanical properties and disintegration times were measured with pharmacopoeial and alternative methods and compared with the in vivo results. The highest correlation with oral disintegration time was found in the case of own-construction apparatus with additional weight and the employment of the method proposed by Narazaki et al. The correlation coefficients were 0.9994 (p < 0.001), and 0.9907 (p < 0.001) respectively. The pharmacopoeial method correlated with the in vivo data much worse (r = 0.8925, p < 0.05). These results have shown that development of novel biorelevant methods of ODT's disintegration time determination is eligible and scientifically justified.

  5. A comparison of gradual sedation levels using the Comfort-B scale and bispectral index in children on mechanical ventilation in the pediatric intensive care unit

    PubMed Central

    Silva, Cláudia da Costa; Alves, Marta Maria Osório; El Halal, Michel Georges dos Santos; Pinheiro, Sabrina dos Santos; Carvalho, Paulo Roberto Antonacci

    2013-01-01

    Objective Compare the scores resulting from the Comfort-B scale with the bispectral index in children in an intensive care unit. Methods Eleven children between the ages of 1 month and 16 years requiring mechanical ventilation and sedation were simultaneously classified based on the bispectral index and the Comfort-B scale. Their behavior was recorded using digital photography, and the record was later evaluated by three independent evaluators. Agreement tests (Bland-Altman and Kappa) were then performed. The correlation between the two methods (Pearson correlation) was tested. Results In total, 35 observations were performed on 11 patients. Based on the Kappa coefficient, the agreement among evaluators ranged from 0.56 to 0.75 (p<0.001). There was a positive and consistent association between the bispectral index and the Comfort-B scale [r=0.424 (p=0.011) to r=0.498 (p=0.002)]. Conclusion Due to the strong correlation between the independent evaluators and the consistent correlation between the two methods, the results suggest that the Comfort-B scale is reproducible and useful in classifying the level of sedation in children requiring mechanical ventilation. PMID:24553512

  6. Ground/Flight Correlation of Aerodynamic Loads with Structural Response

    NASA Technical Reports Server (NTRS)

    Mangalam, Arun S.; Davis, Mark C.

    2009-01-01

    United States Air Force Research Laboratory (AFRL) ground tests at the NASA Transonic Dynamics Tunnel (TDT) and NASA flight tests provide a basis and methodology for in-flight characterization of the aeroelastic performance through the monitoring of the fluid-structure interaction using surface flow sensors. NASA NF-15B flight tests provided a unique opportunity to test the correlation of aerodynamic loads with sectional flow attachment/detachment points, also known as flow bifurcation points (FBPs), as observed in previous wind tunnel tests. The NF-15B tail was instrumented with hot-film sensors and strain gages for measuring root-bending strains. These data were gathered via selected sideslip maneuvers performed at level flight and subsonic speeds. The aerodynamic loads generated by the sideslip maneuver resulted in root-bending strains and hot-film sensor signals near the stagnation region that were highly correlated. For the TDT tests, a flexible wing section developed under the AFRL SensorCraft program was instrumented with strain gages, accelerometers, and hot-film sensors at multiple span stations. The TDT tests provided data showing a gradual phase change between the FBP and the structural mode occurred during a resonant condition as the wings structural modes were excited by the tunnel-generated gusts.

  7. Characterizing the Joint Effect of Diverse Test-Statistic Correlation Structures and Effect Size on False Discovery Rates in a Multiple-Comparison Study of Many Outcome Measures

    NASA Technical Reports Server (NTRS)

    Feiveson, Alan H.; Ploutz-Snyder, Robert; Fiedler, James

    2011-01-01

    In their 2009 Annals of Statistics paper, Gavrilov, Benjamini, and Sarkar report the results of a simulation assessing the robustness of their adaptive step-down procedure (GBS) for controlling the false discovery rate (FDR) when normally distributed test statistics are serially correlated. In this study we extend the investigation to the case of multiple comparisons involving correlated non-central t-statistics, in particular when several treatments or time periods are being compared to a control in a repeated-measures design with many dependent outcome measures. In addition, we consider several dependence structures other than serial correlation and illustrate how the FDR depends on the interaction between effect size and the type of correlation structure as indexed by Foerstner s distance metric from an identity. The relationship between the correlation matrix R of the original dependent variables and R, the correlation matrix of associated t-statistics is also studied. In general R depends not only on R, but also on sample size and the signed effect sizes for the multiple comparisons.

  8. Liquid propellant thermal conditioning system test program

    NASA Technical Reports Server (NTRS)

    Bullard, B. R.

    1972-01-01

    Results are presented from more than 1500 hours of testing on a liquid hydrogen thermal conditioning unit. Test parameters included: mixer and vent flow rates; tank size; ullage volume; pressurant gas; pressurant temperature; pressure level; and heat rate. Gaseous hydrogen and helium were used as pressurants. Analytical models were developed to correlate the test data and relate the performance to that anticipated in zero gravity. Experimental and theoretical results are presented which relate the variables controlling vapor condensation at a moving interface.

  9. [Correlation between results of PCR and specific serological tests in diagnosis of Epstein-Barr virus in patients with mononucleosis syndrome].

    PubMed

    Banko, A V; Lazarević, I B; Cupić, M D; Knezević, A M; Stevanović, G D; Krejović-Trivić, S B; Jovanović, T P

    2009-01-01

    Routine laboratory diagnosis of infectious mononucleosis is based on EBV serological testing, but due to problems in interpretation of results, molecular methods, especially PCR, are often necessary. The aim of the present study was to investigate correlation between results of PCR and specific serological tests in diagnosis of Epstein-Barr virus in patients with mononucleosis syndrome. The study comprised 68 patients with mononucleosis syndrome. Their blood samples were tested using ELISA for detection of 4 EBV specific antibodies (anti-VCA IgM and IgG, anti-EA-D IgG and anti-EBNA-1 IgG) and PCR for detection of EBV DNA. According to results of serology 42 patients had acute primary infection, 2 reactivation, 1 chronic active infection, 19 past infection, and 4 have been EBV seronegative. EBV DNA was detected in 17 patients (25%) and all of them were serologically defined as acutely infected. PCR was useful for resolving unclear serology results. Specific serology is the first step in diagnosis of IM, but PCR may serve as a useful additional diagnostic tool for clarifying serological dilemmas, reaching final diagnosis and defining status of the infection.

  10. Activities of daily living and manual hand dexterity in persons with idiopathic parkinson disease.

    PubMed

    Choi, Yoo-Im; Song, Chiang-Soon; Chun, Byung-Yoon

    2017-03-01

    [Purpose] The purpose of this study was to evaluate the relationship between daily activities and manual dexterity in persons with Parkinson disease. [Subjects and Methods] The study participants were 25 patients with idiopathic Parkinson disease. This study used two clinical tools, the box-and-block test and Schwab and England Activities of Daily Living scale, to investigate the relationship between manual dexterity and Schwab and England Activities of Daily Living score. [Results] A positive correlation was observed between the Schwab and England Activities of Daily Living and the box-and-block test scores on the more and less affected sides. Moreover, the Schwab and England Activities of Daily Living score had a greater correlation with the box-and-block test score on the less affected side than that on the more affected side. [Conclusion] Manual dexterity and activities of daily living showed a positive correlation in individuals with Parkinson disease. The results of this study suggest that manual dexterity is an important factor for predicting physical performance in daily living in persons with Parkinson disease.

  11. Everyday Cognition: Age and Intellectual Ability Correlates

    PubMed Central

    Allaire, Jason C.; Marsiske, Michael

    2010-01-01

    The primary aim of this study was to examine the relationship between a new battery of everyday cognition measures, which assessed 4 cognitive abilities within 3 familiar real-world domains, and traditional psychometric tests of the same basic cognitive abilities. Several theoreticians have argued that everyday cognition measures are somewhat distinct from traditional cognitive assessment approaches, and the authors investigated this assertion correlationally in the present study. The sample consisted of 174 community-dwelling older adults from the Detroit metropolitan area, who had an average age of 73 years. Major results of the study showed that (a) each everyday cognitive test was strongly correlated with the basic cognitive abilities; (b) several basic abilities, as well as measures of domain-specific knowledge, predicted everyday cognitive performance; and (c) everyday and basic measures were similarly related to age. The results suggest that everyday cognition is not unrelated to traditional measures, nor is it less sensitive to age-related differences. PMID:10632150

  12. The Test of Logical Thinking as a predictor of first-year pharmacy students' performance in required first-year courses.

    PubMed

    Etzler, Frank M; Madden, Michael

    2014-08-15

    To investigate the correlation of scores on the Test of Logical Thinking (TOLT) with first-year pharmacy students' performance in selected courses. The TOLT was administered to 130 first-year pharmacy students. The examination was administered during the first quarter in a single session. The TOLT scores correlated with grades earned in Pharmaceutical Calculations, Physical Pharmacy, and Basic Pharmacokinetics courses. Performance on the TOLT has been correlated to performance in courses that required the ability to use quantitative reasoning to complete required tasks. In the future, it may be possible to recommend remediation, retention, and/or admission based in part on the results from the TOLT.

  13. Digital Image Correlation Techniques Applied to Large Scale Rocket Engine Testing

    NASA Technical Reports Server (NTRS)

    Gradl, Paul R.

    2016-01-01

    Rocket engine hot-fire ground testing is necessary to understand component performance, reliability and engine system interactions during development. The J-2X upper stage engine completed a series of developmental hot-fire tests that derived performance of the engine and components, validated analytical models and provided the necessary data to identify where design changes, process improvements and technology development were needed. The J-2X development engines were heavily instrumented to provide the data necessary to support these activities which enabled the team to investigate any anomalies experienced during the test program. This paper describes the development of an optical digital image correlation technique to augment the data provided by traditional strain gauges which are prone to debonding at elevated temperatures and limited to localized measurements. The feasibility of this optical measurement system was demonstrated during full scale hot-fire testing of J-2X, during which a digital image correlation system, incorporating a pair of high speed cameras to measure three-dimensional, real-time displacements and strains was installed and operated under the extreme environments present on the test stand. The camera and facility setup, pre-test calibrations, data collection, hot-fire test data collection and post-test analysis and results are presented in this paper.

  14. Establishment of a new in vitro test method for evaluation of eye irritancy using a reconstructed human corneal epithelial model, LabCyte CORNEA-MODEL.

    PubMed

    Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-ichiro

    2013-12-01

    Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Physical Aspects of Healthy Aging: Assessments of Three Measures of Balance for Studies in Middle-Aged and Older Adults

    PubMed Central

    Ceria-Ulep, Clementina D.; Grove, John; Chen, Randi; Masaki, Kamal H.; Rodriguez, Beatriz L.; Donlon, Tim A.; Guralnik, Jack; Willcox, Bradley J.; Willcox, D. Craig; Nigg, Claudio; Curb, J. David

    2010-01-01

    Objectives. To investigate the reliability and correlations with age of the balance components of the EPESE, NHANES, and the Good Balance Platform System (GBPS) in a normal population of adults. Design. Cross-sectional. Setting. Urban Medical Center in the Pacific. Participants. A random sample of 203 healthy offspring of Honolulu Heart Program participants, ages 38–71. Measurements. Subjects were examined twice at visits one week apart using the balance components of the EPESE, NHANES, and the good balance system tests. Results. The EPESE and NHANES batteries of tests were not sufficiently challenging to allow successful discrimination among subjects in good health, even older subjects. The GBPS allowed objective quantitative measurements, but the test-retest correlations generally were not high. The GBPS variables correlated with age only when subjects stood on a foam pad; they also were correlated with anthropometric variables. Conclusion. Both EPESE and NHANES balance tests were too easy for healthy subjects. The GBPS had generally low reliability coefficients except for the most difficult testing condition (foam pad, eyes closed). Both height and body fat were associated with GBPS scores, necessitating adjusting for these variables if using balance as a predictor of future health. PMID:21437003

  16. Understanding protocol performance: impact of test performance.

    PubMed

    Turner, Robert G

    2013-01-01

    This is the second of two articles that examine the factors that determine protocol performance. The objective of these articles is to provide a general understanding of protocol performance that can be used to estimate performance, establish limits on performance, decide if a protocol is justified, and ultimately select a protocol. The first article was concerned with protocol criterion and test correlation. It demonstrated the advantages and disadvantages of different criterion when all tests had the same performance. It also examined the impact of increasing test correlation on protocol performance and the characteristics of the different criteria. To examine the impact on protocol performance when individual tests in a protocol have different performance. This is evaluated for different criteria and test correlations. The results of the two articles are combined and summarized. A mathematical model is used to calculate protocol performance for different protocol criteria and test correlations when there are small to large variations in the performance of individual tests in the protocol. The performance of the individual tests that make up a protocol has a significant impact on the performance of the protocol. As expected, the better the performance of the individual tests, the better the performance of the protocol. Many of the characteristics of the different criteria are relatively independent of the variation in the performance of the individual tests. However, increasing test variation degrades some criteria advantages and causes a new disadvantage to appear. This negative impact increases as test variation increases and as more tests are added to the protocol. Best protocol performance is obtained when individual tests are uncorrelated and have the same performance. In general, the greater the variation in the performance of tests in the protocol, the more detrimental this variation is to protocol performance. Since this negative impact is increased as more tests are added to the protocol, greater test variation indicates using fewer tests in the protocol. American Academy of Audiology.

  17. Validity, Reliability, and Performance Determinants of a New Job-Specific Anaerobic Work Capacity Test for the Norwegian Navy Special Operations Command.

    PubMed

    Angeltveit, Andreas; Paulsen, Gøran; Solberg, Paul A; Raastad, Truls

    2016-02-01

    Operators in Special Operation Forces (SOF) have a particularly demanding profession where physical and psychological capacities can be challenged to the extremes. The diversity of physical capacities needed depend on the mission. Consequently, tests used to monitor SOF operators' physical fitness should cover a broad range of physical capacities. Whereas tests for strength and aerobic endurance are established, there is no test for specific anaerobic work capacity described in the literature. The purpose of this study was therefore to evaluate the reliability, validity, and to identify performance determinants of a new test developed for testing specific anaerobic work capacity in SOF operators. Nineteen active young students were included in the concurrent validity part of the study. The students performed the evacuation (EVAC) test 3 times and the results were compared for reliability and with performance in the Wingate cycle test, 300-m sprint, and a maximal accumulated oxygen deficit (MAOD) test. In part II of the study, 21 Norwegian Navy Special Operations Command operators conducted the EVAC test, anthropometric measurements, a dual x-ray absorptiometry scan, leg press, isokinetic knee extensions, maximal oxygen uptake test, and countermovement jump (CMJ) test. The EVAC test showed good reliability after 1 familiarization trial (intraclass correlation = 0.89; coefficient of variance = 3.7%). The EVAC test correlated well with the Wingate test (r = -0.68), 300-m sprint time (r = 0.51), and 300-m mean power (W) (r = -0.67). No significant correlation was found with the MAOD test. In part II of the study, height, body mass, lean body mass, isokinetic knee extension torque, maximal oxygen uptake, and maximal power in a CMJ was significantly correlated with performance in the EVAC test. The EVAC test is a reliable and valid test for anaerobic work capacity for SOF operators, and muscle mass, leg strength, and leg power seem to be the most important determinants of performance.

  18. Reliability and factorial validity of flexibility tests for team sports.

    PubMed

    Sporis, Goran; Vucetic, Vlatko; Jovanovic, Mario; Jukic, Igor; Omrcen, Darija

    2011-04-01

    The main goal of this method paper was to evaluate the reliability and factorial validity of flexibility tests used in soccer, and to do crossvalidation study on 2 other team sports using handball and basketball players. The second aim was to compare the validity of the different tests and evaluate the flexibility of soccer players; the third was to determine the positional differences between attackers, defenders, and midfielders in all flexibility tests. One hundred and fifty (n = 150) elite male junior soccer players, members of the First Croatian Junior League Teams, and 60 (n = 60) handball and 60 (n = 60) basketball players also members of the First Croatian Junior League Teams volunteered to participate in the study, tested for the purpose of crossvalidation. The SAR and V-SAR had the greatest AVR and ICC. The within-subjects variation ranged from between 0.3 and 3.8%. The lowest value of CV was found between the LSPL and LSPR. Low to moderate statistically significant correlation coefficients were found among all the measured flexibility tests. It was observed that the greatest correlations existed between the SAR and V-SAR (r = 0.65) and between the LLSR and LLSL (r = 0.56). Statistically significant correlations were also observed between the BLPL and BLPR (r = 0.62). The principal components factor analysis of 9 flexibility tests resulted in the extraction of 3 significant components. The results of this study have the following implications for the assessment of flexibility in soccer: (a) all flexibility tests used in this study have the acceptable between and within-subjects reliability and they can be used to estimate the flexibility of soccer players; (b) the LSPL and LSPR tests are the most reliable and valid flexibility tests for the estimation of flexibility of professional soccer players.

  19. Near-space flight of a correlated photon system

    PubMed Central

    Tang, Zhongkan; Chandrasekara, Rakhitha; Sean, Yau Yong; Cheng, Cliff; Wildfeuer, Christoph; Ling, Alexander

    2014-01-01

    We report the successful test flight of a device for generating and monitoring correlated photon pairs under near-space conditions up to 35.5 km altitude. Data from ground based qualification tests and the high altitude experiment demonstrate that the device continues to operate even under harsh environmental conditions. The design of the rugged, compact and power-efficient photon pair system is presented. This design enables autonomous photon pair systems to be deployed on low-resource platforms such as nanosatellites hosting remote nodes of a quantum key distribution network. These results pave the way for tests of entangled photon technology in low earth orbit. PMID:25219935

  20. Novel application of a Wii remote to measure spasticity with the pendulum test: Proof of concept

    PubMed Central

    Yeh, Chien-Hung; Hung, Chi-Yao; Wang, Yung-Hung; Hsu, Wei-Tai; Chang, Yi-Chung; Yeh, Jia-Rong; Lee, Po-Lei; Hu, Kun; Kang, Jiunn-Horng; Lo, Men-Tzung

    2016-01-01

    Background The pendulum test is a standard clinical test for quantifying the severity of spasticity. In the test, an electrogoniometer is typically used to measure the knee angular motion. The device is costly and difficult to set up such that the pendulum test is normally time consuming. Objective The goal of this study is to determine whether a Nintendo Wii remote can replace the electrogroniometer for reliable assessment of the angular motion of the knee in the pendulum test. Methods The pendulum test was performed in three control participants and 13 hemiplegic stroke patients using both a Wii remote and an electrogoniometer. The correlation coefficient and the Bland–Altman difference plot were used to compare the results obtained from the two devices. The Wilcoxon signed-rank test was used to compare the difference between hemiplegia-affected and nonaffected sides in the hemiplegic stroke patients. Results There was a fair to strong correlation between measurements from the Wii remote and the electrogoniometer (0.513 < R2 < 0.800). Small but consistent differences between the Wii remote and electrogoniometer were identified from the Bland–Altman difference plot. Within the hemiplegic stroke patients, both devices successfully distinguished the hemiplegia-affected (spastic) side from the nonaffected (nonspastic) side (both with p < .0001*). In addition, the intraclass correlation coefficient, standard error of measurement, and minimum detectable differences were highly consistent for both devices. Conclusion Our findings suggest that the Wii remote may serve as a convenient and cost-efficient tool for the assessment of spasticity. PMID:26669955

  1. Heritability of Boldness and Hypoxia Avoidance in European Seabass, Dicentrarchus labrax.

    PubMed

    Ferrari, Sébastien; Horri, Khaled; Allal, François; Vergnet, Alain; Benhaim, David; Vandeputte, Marc; Chatain, Béatrice; Bégout, Marie-Laure

    2016-01-01

    To understand the genetic basis of coping style in European seabass, fish from a full factorial mating (10 females x 50 males) were reared in common garden and individually tagged. Individuals coping style was characterized through behavior tests at four different ages, categorizing fish into proactive or reactive: a hypoxia avoidance test (at 255 days post hatching, dph) and 3 risk-taking tests (at 276, 286 and 304 dph). We observed significant heritability of the coping style, higher for the average of risk-taking scores (h2 = 0.45 ± 0.14) than for the hypoxia avoidance test (h2 = 0.19 ± 0.10). The genetic correlations between the three risk-taking scores were very high (rA = 0.96-0.99) showing that although their repeatability was moderately high (rP = 0.64-0.72), successive risk-taking tests evaluated the same genetic variation. A mild genetic correlation between the results of the hypoxia avoidance test and the average of risk-taking scores (0.45 ± 0.27) suggested that hypoxia avoidance and risk-taking tests do not address exactly the same behavioral and physiological responses. Genetic correlations between weight and risk taking traits showed negative values whatever the test used in our population i.e. reactive individual weights were larger. The results of this quantitative genetic analysis suggest a potential for the development of selection programs based on coping styles that could increase seabass welfare without altering growth performances. Overall, it also contributes to a better understanding of the origin and the significance of individual behavioral differences.

  2. Evaluation of seismic testing for quality assurance of lime-stabilized soil.

    DOT National Transportation Integrated Search

    2013-08-01

    This study sought to determine the technical feasibility of using seismic techniques to measure the : laboratory and field seismic modulus of lime-stabilized soils (LSS), and to compare/correlate test results : from bench-top (free-free resonance) se...

  3. Full-scale locomotive dynamic crash testing and correlations : C-39 type locomotive colliding with a loaded hopper car (test 7).

    DOT National Transportation Integrated Search

    2011-09-01

    This report presents the results of a locomotive and three loaded hopper car consist traveling at 29 miles per hour colliding with a stationary consist of 35 loaded hopper cars. The details of test instrumentation, LS-DYNA finite element simulation, ...

  4. Testing for Seed Quality in Southern Oaks

    Treesearch

    F.T. Bonner

    1984-01-01

    Expressions of germination rate, such as peak value (PV) or mean germination time (MGT), provide good estimates of acorn quality, but test completion requires a minimum of 3 weeks. For more rapid estimates, tetrazolium staining is recommended. Some seed test results were significantly correlated with nursery germination of cherrybark and water oaks, but not with...

  5. Standardized performance tests of collectors of solar thermal energy: A selectively coated, steel collector with one transparent cover

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Basic test results are presented of a flat-plate solar collector whose performance was determined in solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and coolant flow rates. Collector efficiency was correlated in terms of inlet temperature and flux level.

  6. Easiness of Use and Validity Testing of VS-SENSE Device for Detection of Abnormal Vaginal Flora and Bacterial Vaginosis

    PubMed Central

    Donders, Gilbert G. G.; Marconi, Camila; Bellen, Gert

    2010-01-01

    Accessing vaginal pH is fundamental during gynaecological visit for the detection of abnormal vaginal flora (AVF), but use of pH strips may be time-consuming and difficult to interpret. The aim of this study was to evaluate the VS-SENSE test (Common Sense Ltd, Caesarea, Israel) as a tool for the diagnosis of AVF and its correlation with abnormal pH and bacterial vaginosis (BV). The study population consisted of 45 women with vaginal pH ≥ 4.5 and 45 women with normal pH. Vaginal samples were evaluated by VS-SENSE test, microscopy and microbiologic cultures. Comparing with pH strips results, VS-SENSE test specificity was 97.8% and sensitivity of 91%. All severe cases of BV and aerobic vaginitis (AV) were detected by the test. Only one case with normal pH had an unclear result. Concluding, VS-SENSE test is easy to perform, and it correlates with increased pH, AVF, and the severe cases of BV and AV. PMID:20953405

  7. Easiness of use and validity testing of VS-SENSE device for detection of abnormal vaginal flora and bacterial vaginosis.

    PubMed

    Donders, Gilbert G G; Marconi, Camila; Bellen, Gert

    2010-01-01

    Accessing vaginal pH is fundamental during gynaecological visit for the detection of abnormal vaginal flora (AVF), but use of pH strips may be time-consuming and difficult to interpret. The aim of this study was to evaluate the VS-SENSE test (Common Sense Ltd, Caesarea, Israel) as a tool for the diagnosis of AVF and its correlation with abnormal pH and bacterial vaginosis (BV). The study population consisted of 45 women with vaginal pH ≥ 4.5 and 45 women with normal pH. Vaginal samples were evaluated by VS-SENSE test, microscopy and microbiologic cultures. Comparing with pH strips results, VS-SENSE test specificity was 97.8% and sensitivity of 91%. All severe cases of BV and aerobic vaginitis (AV) were detected by the test. Only one case with normal pH had an unclear result. Concluding, VS-SENSE test is easy to perform, and it correlates with increased pH, AVF, and the severe cases of BV and AV.

  8. Correlates of invalid neuropsychological test performance after traumatic brain injury.

    PubMed

    Donders, Jacobus; Boonstra, Tyler

    2007-03-01

    To investigate external correlates of invalid test performance after traumatic brain injury, as assessed by the California Verbal Learning Test - Second Edition (CVLT-II) and Word Memory Test (WMT). Consecutive 2-year series of rehabilitation referrals with a diagnosis of traumatic brain injury (n = 87). Logistic regression analysis was used to determine which demographic and neurological variables best differentiated those with vs. without actuarial CVLT-II or WMT evidence for invalid responding. Twenty-one participants (about 24%) performed in the invalid range. The combination of a premorbid psychiatric history with minimal or no coma was associated with an approximately four-fold increase in the likelihood of invalid performance. Premorbid psychosocial complicating factors constitute a significant threat to validity of neuropsychological test results after (especially mild) traumatic brain injury. At the same time, care should be taken to not routinely assume that all persons with mild traumatic brain injury and premorbid psychiatric histories are simply malingering. The WMT appears to be a promising instrument for the purpose of identifying those cases where neuropsychological test results are confounded by factors not directly related to acquired cerebral impairment.

  9. The relationship between the yo-yo tests, anaerobic performance and aerobic performance in young soccer players.

    PubMed

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-12-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1-2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = -0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = -0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players.

  10. The Relationship Between the Yo-Yo Tests, Anaerobic Performance and Aerobic Performance in Young Soccer Players

    PubMed Central

    Karakoç, Barış; Akalan, Cengiz; Alemdaroğlu, Utku; Arslan, Erşan

    2012-01-01

    The purposes of this study were to determine the relationship between performance in the Yo-Yo intermittent recovery test level 1 (YIRT1), the Yo-Yo intermittent recovery test level 2 (YIRT2) and the Yo-Yo endurance test (continuous) (YET) with maximal oxygen uptake (VO2max) and Wingate anaerobic performance (WaNT) test results in young soccer players (age 15.00 ± 0.0 years, body height 176.3 ± 4.2 cm and body mass 68.1 ± 3.6 kg). An ergospirometry device was used during the treadmill test (TRT) to determine VO2max. At the end of the study, significant differences were found between the Yo-Yo tests and TRT in terms of HRmax (TRT = 195,92, YIRT1 = 197,83, YIRT2 = 198,5 YET = 198) (p > 0.05). While there were moderate correlations between VO2max and YIRT 1–2 performances (respectively, r = 0.56, r = 0.53), there was only a weak relationship between VO2max and YET performance (r = 0.43) (distance covered). There were also moderate significant negative correlations between performance in the YIRT2 and peak power measured in the WaNT (r = −0.55), although there were no significant correlations between performance in the three tests and average power. A moderate negative correlation was found between performance in the YIRT2 and Fatigue index (FI) (r = −0,66). In conclusion, the YIRT2 may be a more suitable field test for determining both aerobic and anaerobic performance in soccer players. PMID:23486008

  11. Pretest information for a test to validate plume simulation procedures (FA-17)

    NASA Technical Reports Server (NTRS)

    Hair, L. M.

    1978-01-01

    The results of an effort to plan a final verification wind tunnel test to validate the recommended correlation parameters and application techniques were presented. The test planning effort was complete except for test site finalization and the associated coordination. Two suitable test sites were identified. Desired test conditions were shown. Subsequent sections of this report present the selected model and test site, instrumentation of this model, planned test operations, and some concluding remarks.

  12. Development and psychometric evaluation of an information literacy self-efficacy survey and an information literacy knowledge test.

    PubMed

    Tepe, Rodger; Tepe, Chabha

    2015-03-01

    To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. In this test-retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. The IL self-efficacy survey demonstrated good reliability (test-retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test-retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments.

  13. The reliability and validity of the SF-8 with a conflict-affected population in northern Uganda.

    PubMed

    Roberts, Bayard; Browne, John; Ocaka, Kaducu Felix; Oyok, Thomas; Sondorp, Egbert

    2008-12-02

    The SF-8 is a health-related quality of life instrument that could provide a useful means of assessing general physical and mental health amongst populations affected by conflict. The purpose of this study was to test the validity and reliability of the SF-8 with a conflict-affected population in northern Uganda. A cross-sectional multi-staged, random cluster survey was conducted with 1206 adults in camps for internally displaced persons in Gulu and Amuru districts of northern Uganda. Data quality was assessed by analysing the number of incomplete responses to SF-8 items. Response distribution was analysed using aggregate endorsement frequency. Test-retest reliability was assessed in a separate smaller survey using the intraclass correlation test. Construct validity was measured using principal component analysis, and the Pearson Correlation test for item-summary score correlation and inter-instrument correlations. Known groups validity was assessed using a two sample t-test to evaluates the ability of the SF-8 to discriminate between groups known to have, and not have, physical and mental health problems. The SF-8 showed excellent data quality. It showed acceptable item response distribution based upon analysis of aggregate endorsement frequencies. Test-retest showed a good intraclass correlation of 0.61 for PCS and 0.68 for MCS. The principal component analysis indicated strong construct validity and concurred with the results of the validity tests by the SF-8 developers. The SF-8 also showed strong construct validity between the 8 items and PCS and MCS summary score, moderate inter-instrument validity, and strong known groups validity. This study provides evidence on the reliability and validity of the SF-8 amongst IDPs in northern Uganda.

  14. Has the "Equal Environments" assumption been tested in twin studies?

    PubMed

    Eaves, Lindon; Foley, Debra; Silberg, Judy

    2003-12-01

    A recurring criticism of the twin method for quantifying genetic and environmental components of human differences is the necessity of the so-called "equal environments assumption" (EEA) (i.e., that monozygotic and dizygotic twins experience equally correlated environments). It has been proposed to test the EEA by stratifying twin correlations by indices of the amount of shared environment. However, relevant environments may also be influenced by genetic differences. We present a model for the role of genetic factors in niche selection by twins that may account for variation in indices of the shared twin environment (e.g., contact between members of twin pairs). Simulations reveal that stratification of twin correlations by amount of contact can yield spurious evidence of large shared environmental effects in some strata and even give false indications of genotype x environment interaction. The stratification approach to testing the equal environments assumption may be misleading and the results of such tests may actually be consistent with a simpler theory of the role of genetic factors in niche selection.

  15. Comparison of Hard Surface and Soft Soil Impact Performance of a Crashworthy Composite Fuselage Concept

    NASA Technical Reports Server (NTRS)

    Sareen, Ashish K.; Sparks, Chad; Mullins, B. R., Jr.; Fasanella, Edwin; Jackson, Karen

    2002-01-01

    A comparison of the soft soil and hard surface impact performance of a crashworthy composite fuselage concept has been performed. Specifically, comparisons of the peak acceleration values, pulse duration, and onset rate at specific locations on the fuselage were evaluated. In a prior research program, the composite fuselage section was impacted at 25 feet per second onto concrete at the Impact Dynamics Research Facility (IDRF) at NASA Langley Research Center. A soft soil test was conducted at the same impact velocity as a part of the NRTC/RITA Crashworthy and Energy Absorbing Structures project. In addition to comparisons of soft soil and hard surface test results, an MSC. Dytran dynamic finite element model was developed to evaluate the test analysis correlation. In addition, modeling parameters and techniques affecting test analysis correlation are discussed. Once correlated, the analytical methodology will be used in follow-on work to evaluate the specific energy absorption of various subfloor concepts for improved crash protection during hard surface and soft soil impacts.

  16. Inquiry-based laboratory investigations and student performance on standardized tests in biological science

    NASA Astrophysics Data System (ADS)

    Patke, Usha

    Achievement data from the 3rd International Mathematics and Sciences Study and Program for International Student Assessment in science have indicated that Black students from economically disadvantaged families underachieve at alarming rates in comparison to White and economically advantaged peer groups. The study site was a predominately Black, urban school district experiencing underachievement. The purpose of this correlational study was to examine the relationship between students' use of inquiry-based laboratory investigations and their performance on the Biology End of Course Test, as well as to examine the relationship while partialling out the effects of student gender. Constructivist theory formed the theoretical foundation of the study. Students' perceived levels of experience with inquiry-based laboratory investigations were measured using the Laboratory Program Variable Inventory (LPVI) survey. LPVI scores of 256 students were correlated with test scores and were examined by student gender. The Pearson correlation coefficient revealed a small direct correlation between students' experience in inquiry-based laboratory investigation classes and standardized test scores on the Biology EOCT. A partial correlational analysis indicated that the correlation remained after controlling for gender. This study may prompt a change from teacher-centered to student-centered pedagogy at the local site in order to increase academic achievement for all students. The results of this study may also influence administrators and policy makers to initiate local, state, or nationwide curricular development. A change in curriculum may promote social change as students become more competent, and more able, to succeed in life beyond secondary school.

  17. Correlation of transonic-cone preston-tube data and skin friction

    NASA Technical Reports Server (NTRS)

    Abu-Mostafa, A. S.; Reed, T. D.

    1984-01-01

    Preston-tube measurements obtained on the Arnold Engineering Development Center (AEDC) Transition Cone have been correlated with theoretical skin friction coefficients in transitional and turbulent flow. This has been done for the NASA Ames 11-Ft Transonic Wind Tunnel (11 TWT) and flight tests. The developed semi-empirical correlations of Preston-tube data have been used to derive a calibration procedure for the 11 TWT flow quality. This procedure has been applied to the corrected laminar data, and an effective freestream unit Reynolds number is defined by requiring a matching of the average Preston-tube pressure in flight and in the tunnel. This study finds that the operating Reynolds number is below the effective value required for a match in laminar Preston-tube data. The distribution of this effective Reynolds number with Mach number correlates well with the freestream noise level in this tunnel. Analyses of transitional and turbulent data, however, did not result in effective Reynolds numbers that can be correlated with background noise. This is a result of the fact that vorticity fluctuations present in transitional and turbulent boundary layers dominate Preston-tube pressure fluctuations and, therefore, mask the tunnel noise eff ects. So, in order to calibrate the effects of noise on transonic wind tunnel tests only laminar data should be used, preferably at flow conditions similar to those in flight tests. To calibrate the effects of transonic wind-tunnel noise on drag measurements, however, the Preston-tube data must be supplemented with direct measurements of skin friction.

  18. Kolmogorov-Smirnov test for spatially correlated data

    USGS Publications Warehouse

    Olea, R.A.; Pawlowsky-Glahn, V.

    2009-01-01

    The Kolmogorov-Smirnov test is a convenient method for investigating whether two underlying univariate probability distributions can be regarded as undistinguishable from each other or whether an underlying probability distribution differs from a hypothesized distribution. Application of the test requires that the sample be unbiased and the outcomes be independent and identically distributed, conditions that are violated in several degrees by spatially continuous attributes, such as topographical elevation. A generalized form of the bootstrap method is used here for the purpose of modeling the distribution of the statistic D of the Kolmogorov-Smirnov test. The innovation is in the resampling, which in the traditional formulation of bootstrap is done by drawing from the empirical sample with replacement presuming independence. The generalization consists of preparing resamplings with the same spatial correlation as the empirical sample. This is accomplished by reading the value of unconditional stochastic realizations at the sampling locations, realizations that are generated by simulated annealing. The new approach was tested by two empirical samples taken from an exhaustive sample closely following a lognormal distribution. One sample was a regular, unbiased sample while the other one was a clustered, preferential sample that had to be preprocessed. Our results show that the p-value for the spatially correlated case is always larger that the p-value of the statistic in the absence of spatial correlation, which is in agreement with the fact that the information content of an uncorrelated sample is larger than the one for a spatially correlated sample of the same size. ?? Springer-Verlag 2008.

  19. Correlation between blink reflex abnormalities and magnetic resonance imaging findings in patients with multiple sclerosis.

    PubMed

    Degirmenci, Eylem; Erdogan, Cagdas; Bir, Levent Sinan

    2013-09-01

    This study investigates the correlation between brain magnetic resonance imaging findings and blink reflex abnormalities in patients with relapsing remitting multiple sclerosis. Twenty-six patients and 17 healthy subjects were included in this study. Blink reflex test (BRT) results were obtained using right and left stimulations; thus, 52 BRT results were recorded for the patient group, and 34 BRT results were recorded for the control group. The magnetic resonance imaging (MRI) findings were classified based on the existence of brainstem lesions (hyperintense lesion on T2 weighted (W) and fast fluid-attenuated inversion recovery MRI or contrast-enhancing lesion on T1W MRI). Correlation analysis was performed for the BRT and MRI findings. The percentage of individuals with abnormal BRT results (including R1 latency, ipsilateral R2 latency, and contralateral R2 latency) was significantly higher in the patient group as compared to the control group (p values: 0.015, 0.001, and 0.002, respectively). Correlation analysis revealed significant correlations between contralateral R2 latency abnormalities and brainstem lesions (p value: 0.011). Our results showed significant correlation correlations between contralateral R2 latency abnormalities and brainstem lesions and these results may be explained the effects of multiple demyelinating lesions of the brain stem of patients with relapsing remitting multiple sclerosis.

  20. Examination of the properties of IMRT and VMAT beams and evaluation against pre-treatment quality assurance results

    NASA Astrophysics Data System (ADS)

    Crowe, S. B.; Kairn, T.; Middlebrook, N.; Sutherland, B.; Hill, B.; Kenny, J.; Langton, C. M.; Trapp, J. V.

    2015-03-01

    This study aimed to provide a detailed evaluation and comparison of a range of modulated beam evaluation metrics, in terms of their correlation with QA testing results and their variation between treatment sites, for a large number of treatments. Ten metrics including the modulation index (MI), fluence map complexity, modulation complexity score (MCS), mean aperture displacement (MAD) and small aperture score (SAS) were evaluated for 546 beams from 122 intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans targeting the anus, rectum, endometrium, brain, head and neck and prostate. The calculated sets of metrics were evaluated in terms of their relationships to each other and their correlation with the results of electronic portal imaging based quality assurance (QA) evaluations of the treatment beams. Evaluation of the MI, MAD and SAS suggested that beams used in treatments of the anus, rectum, head and neck were more complex than the prostate and brain treatment beams. Seven of the ten beam complexity metrics were found to be strongly correlated with the results from QA testing of the IMRT beams (p < 0.00008). For example, values of SAS (with multileaf collimator apertures narrower than 10 mm defined as ‘small’) less than 0.2 also identified QA passing IMRT beams with 100% specificity. However, few of the metrics are correlated with the results from QA testing of the VMAT beams, whether they were evaluated as whole 360° arcs or as 60° sub-arcs. Select evaluation of beam complexity metrics (at least MI, MCS and SAS) is therefore recommended, as an intermediate step in the IMRT QA chain. Such evaluation may also be useful as a means of periodically reviewing VMAT planning or optimiser performance.

  1. Evaluation of an Immunocapture-Agglutination Test (Brucellacapt) for Serodiagnosis of Human Brucellosis

    PubMed Central

    Orduña, Antonio; Almaraz, Ana; Prado, Ana; Gutierrez, M. Purificación; Garcia-Pascual, Agustina; Dueñas, Ana; Cuervo, Milagros; Abad, Ramon; Hernández, Beatriz; Lorenzo, Belen; Bratos, Miguel A.; Torres, Antonio Rodriguez

    2000-01-01

    We evaluated the validity and the usefulness of a new test for the diagnosis of human brucellosis based on an immunocapture-agglutination technique. A total of 315 sera from 82 patients with a diagnosis of brucellosis, 157 sera from patients in whom brucellosis was suspected but not confirmed, and 412 sera from people living in rural areas with endemic brucellosis were studied. The seroagglutination test (SAT), Coombs anti-Brucella test, and Brucellacapt test were evaluated. All the initial sera from the 82 patients proved to be positive in Brucellacapt and Coombs tests, while only 75 (91.4%) were positive in the SAT. If a ≥1/160 diagnostic threshold titer was defined for the Brucellacapt test, Coombs test, and SAT, the sensitivities were 95.1, 91.5, and 65.8%, respectively. Taking the same diagnostic threshold titer for the 157 sera from the unconfirmed but suspected patients, the specificities of the Brucellacapt, Coombs, and SAT were 81.5, 96.2, and 100%, respectively; for the 412 control sera, the specificities were 99.0, 99.8, and 100%. The diagnostic efficiency (area below the receiver operating characteristic curve) of Brucellacapt was 0.987852 (95% confidence interval [CI], 0.95109 to 0.99286), very similar to the diagnostic efficiency of the Coombs test (0.97611; 95% CI, 0.94781 to 0.99146) and higher than that of SAT (0.91013; 95% CI, 0.86649 to 0.94317). The results of the Brucellacapt test were compared with those of the Coombs test (correlation coefficient, 0.956; P = 0.000) and SAT (correlation coefficient, 0.866; P = 0.000). The study shows very good correlation between the Brucellacapt and Coombs tests, with a high concordance between titers obtained in the two tests. Nevertheless, lower correlation and concordance were found between the Brucellacapt and Coombs tests when the results for titers of ≥1/160 were compared (0.692; P = 0.000). In acute brucellosis, the Brucellacapt and Coombs tests render positive titers of ≥1/160. When the titers are lower, they increase significantly in the following 30 days, despite the evolution of SAT titers. In contrast, Brucellacapt and Coombs titers are always high (≥1/640) in brucellosis with long evolution, whether SAT titers are higher or lower than 1/160. PMID:11060059

  2. Estimating False Discovery Proportion Under Arbitrary Covariance Dependence*

    PubMed Central

    Fan, Jianqing; Han, Xu; Gu, Weijie

    2012-01-01

    Multiple hypothesis testing is a fundamental problem in high dimensional inference, with wide applications in many scientific fields. In genome-wide association studies, tens of thousands of tests are performed simultaneously to find if any SNPs are associated with some traits and those tests are correlated. When test statistics are correlated, false discovery control becomes very challenging under arbitrary dependence. In the current paper, we propose a novel method based on principal factor approximation, which successfully subtracts the common dependence and weakens significantly the correlation structure, to deal with an arbitrary dependence structure. We derive an approximate expression for false discovery proportion (FDP) in large scale multiple testing when a common threshold is used and provide a consistent estimate of realized FDP. This result has important applications in controlling FDR and FDP. Our estimate of realized FDP compares favorably with Efron (2007)’s approach, as demonstrated in the simulated examples. Our approach is further illustrated by some real data applications. We also propose a dependence-adjusted procedure, which is more powerful than the fixed threshold procedure. PMID:24729644

  3. Testing homogeneity of proportion ratios for stratified correlated bilateral data in two-arm randomized clinical trials.

    PubMed

    Pei, Yanbo; Tian, Guo-Liang; Tang, Man-Lai

    2014-11-10

    Stratified data analysis is an important research topic in many biomedical studies and clinical trials. In this article, we develop five test statistics for testing the homogeneity of proportion ratios for stratified correlated bilateral binary data based on an equal correlation model assumption. Bootstrap procedures based on these test statistics are also considered. To evaluate the performance of these statistics and procedures, we conduct Monte Carlo simulations to study their empirical sizes and powers under various scenarios. Our results suggest that the procedure based on score statistic performs well generally and is highly recommended. When the sample size is large, procedures based on the commonly used weighted least square estimate and logarithmic transformation with Mantel-Haenszel estimate are recommended as they do not involve any computation of maximum likelihood estimates requiring iterative algorithms. We also derive approximate sample size formulas based on the recommended test procedures. Finally, we apply the proposed methods to analyze a multi-center randomized clinical trial for scleroderma patients. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Final Report - DuraMelter 100 Tests to Support LAW Glass Formulation Correlation Development, VSL-06R6480-1, Rev. 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, Albert A.; Muller, I. S.; Gong, W.

    2013-12-03

    This report describes the results of work and testing specified by Test Specifications 24590-LAW-TSP-RT-04-004, Rev. 0, Test Plans VSL-05T5480-1, Rev. 0 and Text Exceptions 24590-LAW-TEF-RT-05-00002. The work and any associated testing followed established quality assurance requirements and was conducted as authorized. The descriptions provided in this test report are an accurate account of both the conduct of the work and the data collected. Results required by the Test Plan are reported. Also reported are any unusual or anomalous occurences that are different from the starting hypotheses. The test results and this report have been reviewed and verified.

  5. Spatial Characteristics of F/A-18 Vertical Tail Buffet Pressures Measured in Flight

    NASA Technical Reports Server (NTRS)

    Moses, Robert W.; Shah, Gautam H.

    1998-01-01

    Buffeting is an aeroelastic phenomenon which plagues high performance aircraft, especially those with twin vertical tails, at high angles of attack. Previous wind-tunnel and flight tests were conducted to characterize the buffet loads on the vertical tails by measuring surface pressures, bending moments, and accelerations. Following these tests, buffeting estimates were computed using the measured buffet pressures and compared to the measured responses. The estimates did not match the measured data because the assumed spatial correlation of the buffet pressures was not correct. A better understanding of the partial (spatial) correlation of the differential buffet pressures on the tail was necessary to improve the buffeting estimates. Several wind-tunnel investigations were conducted for this purpose. When combined and compared, the results of these tests show that the partial correlation depends on and scales with flight conditions. One of the remaining questions is whether the windtunnel data is consistent with flight data. Presented herein, cross-spectra and coherence functions calculated from pressures that were measured on the high alpha research vehicle (HARV) indicate that the partial correlation of the buffet pressures in flight agrees with the partial correlation observed in the wind tunnel.

  6. Cortical thickness and surface area correlates with cognitive dysfunction among first-episode psychosis patients.

    PubMed

    Haring, L; Müürsepp, A; Mõttus, R; Ilves, P; Koch, K; Uppin, K; Tarnovskaja, J; Maron, E; Zharkovsky, A; Vasar, E; Vasar, V

    2016-07-01

    In studies using magnetic resonance imaging (MRI), some have reported specific brain structure-function relationships among first-episode psychosis (FEP) patients, but findings are inconsistent. We aimed to localize the brain regions where cortical thickness (CTh) and surface area (cortical area; CA) relate to neurocognition, by performing an MRI on participants and measuring their neurocognitive performance using the Cambridge Neuropsychological Test Automated Battery (CANTAB), in order to investigate any significant differences between FEP patients and control subjects (CS). Exploration of potential correlations between specific cognitive functions and brain structure was performed using CANTAB computer-based neurocognitive testing and a vertex-by-vertex whole-brain MRI analysis of 63 FEP patients and 30 CS. Significant correlations were found between cortical parameters in the frontal, temporal, cingular and occipital brain regions and performance in set-shifting, working memory manipulation, strategy usage and sustained attention tests. These correlations were significantly dissimilar between FEP patients and CS. Significant correlations between CTh and CA with neurocognitive performance were localized in brain areas known to be involved in cognition. The results also suggested a disrupted structure-function relationship in FEP patients compared with CS.

  7. Modal Survey of ETM-3, A 5-Segment Derivative of the Space Shuttle Solid Rocket Booster

    NASA Technical Reports Server (NTRS)

    Nielsen, D.; Townsend, J.; Kappus, K.; Driskill, T.; Torres, I.; Parks, R.

    2005-01-01

    The complex interactions between internal motor generated pressure oscillations and motor structural vibration modes associated with the static test configuration of a Reusable Solid Rocket Motor have potential to generate significant dynamic thrust loads in the 5-segment configuration (Engineering Test Motor 3). Finite element model load predictions for worst-case conditions were generated based on extrapolation of a previously correlated 4-segment motor model. A modal survey was performed on the largest rocket motor to date, Engineering Test Motor #3 (ETM-3), to provide data for finite element model correlation and validation of model generated design loads. The modal survey preparation included pretest analyses to determine an efficient analysis set selection using the Effective Independence Method and test simulations to assure critical test stand component loads did not exceed design limits. Historical Reusable Solid Rocket Motor modal testing, ETM-3 test analysis model development and pre-test loads analyses, as well as test execution, and a comparison of results to pre-test predictions are discussed.

  8. Buckling Testing and Analysis of Space Shuttle Solid Rocket Motor Cylinders

    NASA Technical Reports Server (NTRS)

    Weidner, Thomas J.; Larsen, David V.; McCool, Alex (Technical Monitor)

    2002-01-01

    A series of full-scale buckling tests were performed on the space shuttle Reusable Solid Rocket Motor (RSRM) cylinders. The tests were performed to determine the buckling capability of the cylinders and to provide data for analytical comparison. A nonlinear ANSYS Finite Element Analysis (FEA) model was used to represent and evaluate the testing. Analytical results demonstrated excellent correlation to test results, predicting the failure load within 5%. The analytical value was on the conservative side, predicting a lower failure load than was applied to the test. The resulting study and analysis indicated the important parameters for FEA to accurately predict buckling failure. The resulting method was subsequently used to establish the pre-launch buckling capability of the space shuttle system.

  9. Correlations for reduced-width amplitudes in /sup 49/V

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chou, B.H.; Mitchell, G.E.; Bilpuch, E.G.

    1980-10-13

    Measurement of the relative sign of inelastic proton-channel amplitudes permits the determination of amplitude correlations. Data were obtained for 45 5/2/sup +/ resonances in /sup 49/V. Although the reduced widths in each channel followed a Porter-Thomas distribution, large amplitude correlations were observed. The results are compared with the reduced-width--amplitude distribution of Krieger and Porter. This is the first direct test of the Krieger-Porter distribution.

  10. Evaluating fine motor coordination in children who are not ready for handwriting: which test should we take?

    PubMed

    de Vries, Liesbeth; van Hartingsveldt, Margo J; Cup, Edith H C; Nijhuis-van der Sanden, Maria W G; de Groot, Imelda J M

    2015-06-01

    When children are not ready to write, assessment of fine motor coordination may be indicated. The purpose of this study was to evaluate which fine motor test, the Nine-Hole Peg Test (9-HPT) or the newly developed Timed Test of In-Hand Manipulation (Timed-TIHM), correlates best with handwriting readiness as measured by the Writing Readiness Inventory Tool In Context-Task Performance (WRITIC-TP). From the 119 participating children, 43 were poor performers. Convergent validity of the 9-HPT and Timed-TIHM with WRITIC-TP was determined, and test-retest reliability of the Timed-TIHM was examined in 59 children. The results showed that correlations of the 9-HPT and Timed-TIHM with the WRITIC-TP were similar (rs = -0.40). The 9-HPT and the complex rotation subtask of the Timed-TIHM had a low correlation with the WRITIC-TP in poor performers (rs = -0.30 and -0.32 respectively). Test-retest reliability of the Timed-TIHM was significant (Intraclass Correlation Coefficient = 0.71). Neither of these two fine motor tests is appeared superior. They both relate to different aspects of fine motor performance. One of the limitations of the methodology was unequal numbers of children in subgroups. It is recommended that further research is indicated to evaluate the relation between development of fine motor coordination and handwriting proficiency, on the Timed-TIHM in different age groups. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Quantitative relationship between the local lymph node assay and human skin sensitization assays.

    PubMed

    Schneider, K; Akkan, Z

    2004-06-01

    The local lymph node assay (LLNA) is a new test method which allows for the quantitative assessment of sensitizing potency in the mouse. Here, we investigate the quantitative correlation between results from the LLNA and two human sensitization tests--specifically, human repeat insult patch tests (HRIPTs) and human maximization tests (HMTs). Data for 57 substances were evaluated, of which 46 showed skin sensitizing properties in human tests, whereas 11 yielded negative results in humans. For better comparability data from mouse and human tests were transformed to applied doses per skin area, which ranged over four orders of magnitude for the substances considered. Regression analysis for the 46 human sensitizing substances revealed a significant positive correlation between the LLNA and human tests. The correlation was better between LLNA and HRIPT data (n=23; r=0.77) than between LLNA and HMT data (n=38; r=0.65). The observed scattering of data points is related to various uncertainties, in part associated with insufficiencies of data from older HMT studies. Predominantly negative results in the LLNA for another 11 substances which showed no skin sensitizing activity in human maximization tests further corroborate the correspondence between LLNA and human tests. Based on this analysis, the LLNA can be considered a reliable basis for relative potency assessments for skin sensitizers. Proposals are made for the regulatory exploitation of the LLNA: four potency groups can be established, and assignment of substances to these groups according to the outcome of the LLNA can be used to characterize skin sensitizing potency in substance-specific assessments. Moreover, based on these potency groups, a more adequate consideration of sensitizing substances in preparations becomes possible. It is proposed to replace the current single concentration limit for skin sensitizers in preparations, which leads to an all or nothing classification of a preparation as sensitizing to skin ("R43") in the European Union, by differentiated concentration limits derived from the limits for the four potency groups.

  12. Six-minute stepper test: a valid clinical exercise tolerance test for COPD patients

    PubMed Central

    Grosbois, JM; Riquier, C; Chehere, B; Coquart, J; Béhal, H; Bart, F; Wallaert, B; Chenivesse, C

    2016-01-01

    Introduction Exercise tolerance testing is an integral part of the pulmonary rehabilitation (PR) management of patients with chronic obstructive pulmonary disease (COPD). The 6-minute stepper test (6MST) is a new, well-tolerated, reproducible exercise test, which can be performed without any spatial constraints. Objective The aim of this study was to compare the results of the 6MST to those obtained during a 6-minute walk test (6MWT) and cardiopulmonary exercise testing (CPET) in a cohort of COPD patients. Methods Ninety-one COPD patients managed by outpatient PR and assessed by 6MST, 6MWT, and CPET were retrospectively included in this study. Correlations between the number of steps on the 6MST, the distance covered on the 6MWT, oxygen consumption, and power at the ventilatory threshold and at maximum effort during CPET were analyzed before starting PR, and the improvement on the 6MST and 6MWT was compared after PR. Results The number of steps on the 6MST was significantly correlated with the distance covered on the 6MWT (r=0.56; P<0.0001), the power at maximum effort (r=0.46; P<0.0001), and oxygen consumption at maximum effort (r=0.39; P<0.005). Performances on the 6MST and 6MWT were significantly improved after PR (570 vs 488 steps, P=0.001 and 448 vs 406 m, respectively; P<0.0001). Improvements of the 6MST and 6MWT after PR were significantly correlated (r=0.34; P=0.03). Conclusion The results of this study show that the 6MST is a valid test to evaluate exercise tolerance in COPD patients. The use of this test in clinical practice appears to be particularly relevant for the assessment of patients managed by home PR. PMID:27099483

  13. Correlation between nutritional status and comprehensive physical performance measures among older adults with undernourishment in residential institutions.

    PubMed

    Singh, Devinder K A; Manaf, Zahara A; Yusoff, Noor Aini M; Muhammad, Nur A; Phan, Mei Fang; Shahar, Suzana

    2014-01-01

    The consequences of combined undernourishment and decreased physical performance in older adults are debilitating and increases cost of care. To date, the information regarding the association between nutritional status and physical performance does not provide a complete picture. Most studies used limited or self-reported measures to evaluate physical performance. The objective of this study was to examine the correlation between nutritional status and comprehensive physical performance measures among undernourished older adults who reside in residential institutions. Forty-seven older adults (26 males, 21 females) aged ≥ 60 (69.23 ± 8.63) years who were identified as undernourished from two residential institutions participated in this study. A battery of physical performance tests (10 m gait speed test, dominant hand grip strength test, timed five-repetition sit-to-stand test, ten step test, arm curl test, scratch test, and respiratory muscle strength test), biochemical profiles (serum albumin, hemoglobin, serum ferritin, and prealbumin levels), and falls risk using the short-form Physiological Profile Approach were performed. The Functional Ability Questionnaire and Geriatric Depression Scale were also administered. The results demonstrated that generally older adults with undernourishment scored poorly on the physical performance tests, had depression, and a high risk of falls. Biochemical results demonstrated that 10.9% of the participants were anemic, 63% had hypoalbuminemia (<3.5 g/dL), and 21.7% were at risk of protein energy malnutrition with prealbumin level (100-170 mg/L). A significant correlation (P<0.05) was demonstrated between hand grip strength and ferritin, between self-reported mobility dependence and prealbumin levels, and between self-reported mobility tiredness and body mass index. These results confirm that older adults with undernutrition have poor physical function, higher falls risk, and depression. Clinically, overall health that includes nutritional status, physical function, and depression level should be taken into consideration in the assessment and treatment of older adults residing at residential institutions.

  14. Testing for Soluble ST2 in Heart Failure Patients: Reliability of a Point of Care Method.

    PubMed

    Gruson, Damien; Ferracin, Benjamin; Ahn, Sylvie A; Rousseau, Michel F

    2017-01-01

    Our objective was to determine soluble ST2 (sST2) concentrations in heart failure (HF) patients with a point-of-care (POCT) assay. sST2 levels were measured in 71 HF patients with both POCT and ELISA methods. The concentrations of sST2 were correlated to HF severity and to some established biomarkers of cardiovascular risk. sST2 levels measured with the ASPECT-PLUS POCT method were significantly correlated with the comparison ELISA assay (r = 0.94, p < 0.01) and were related to HF severity. Levels of sST2 measured with the POCT assay were significantly correlated to NT-proBNP (r = 0.57, p < 0.001), BNP (r = 0.75, p < 0.001), Galectin-3 (r = 0.40, p < 0.01) and PTH (1-84) (r = 0.39, p < 0.01). POCT and ELISA methods for sST2 testing were significantly correlated, and our results confirmed also the clinical reliability of the sST2 POCT assay. Furthermore, the POCT method allows a faster delivery of results to physicians.

  15. Technical and investigative support for high density digital satellite recording systems

    NASA Technical Reports Server (NTRS)

    Schultz, R. A.

    1982-01-01

    Methods and results of examinations and tests conducted on magnetic recording tapes under consideration for a high density digital (HDDR) satellite recording system are described. The examinations and tests investigate the performance of tapes with respect to their physical, magnetic and electrical characteristics. The objective of the tests, the likely significance of typical results, and the importance of the characteristics under investigation to the application are included. Theoretical discussions of measurement methods are provided where appropriate. Methods and results are discussed; the results of some sections are tabulated together to facilitate their comparison. The conclusion of each test section relates the test results to their possible significance and attempts to correlate the results of that section with the results of other tests. Some of the sections analyze sources of error inherent in the measurement methods or relate the value of the information obtained to the objectives of the test or the overall purpose of the project.

  16. An Investigation on Formaldehyde Emission Characteristics of Wood Building Materials in Chinese Standard Tests: Product Emission Levels, Measurement Uncertainties, and Data Correlations between Various Tests

    PubMed Central

    Song, Wei; Cao, Yang; Wang, Dandan; Hou, Guojun; Shen, Zaihua; Zhang, Shuangbao

    2015-01-01

    As a large producer and consumer of wood building materials, China suffers product formaldehyde emissions (PFE) but lacks systematic investigations and basic data on Chinese standard emission tests (CST), so this paper presented a first effort on this issue. The PFE of fiberboards, particleboards, blockboards, floorings, and parquets manufactured in Beijing region were characterized by the perforator extraction method (PE), 9–11 L and 40 L desiccator methods (D9, D40), and environmental chamber method (EC) of the Chinese national standard GB 18580; based on statistics of PFE data, measurement uncertainties in CST were evaluated by the Monte Carlo method; moreover, PFE data correlations between tests were established. Results showed: (1) Different tests may give slightly different evaluations on product quality. In PE and D9 tests, blockboards and parquets reached E1 grade for PFE, which can be directly used in indoor environment; but in D40 and EC tests, floorings and parquets achieved E1. (2) In multiple tests, PFE data characterized by PE, D9, and D40 complied with Gaussian distributions, while those characterized by EC followed log-normal distributions. Uncertainties in CST were overall low, with uncertainties for 20 material-method combinations all below 7.5%, and the average uncertainty for each method under 3.5%, thus being acceptable in engineering application. A more complicated material structure and a larger test scale caused higher uncertainties. (3) Conventional linear models applied to correlating PFE values between PE, D9, and EC, with R2 all over 0.840, while novel logarithmic (exponential) models can work better for correlations involving D40, with R2 all beyond 0.901. This research preliminarily demonstrated the effectiveness of CST, where results for D40 presented greater similarities to EC—the currently most reliable test for PFE, thus highlighting the potential of Chinese D40 as a more practical approach in production control and risk assessment. PMID:26656316

  17. A comparative evaluation of Oratest with the microbiological method of assessing caries activity in children

    PubMed Central

    Sundaram, Meenakshi; Nayak, Ullal Anand; Ramalingam, Krishnakumar; Reddy, Venugopal; Rao, Arun Prasad; Mathian, Mahesh

    2013-01-01

    Aims: The aim of this study is to find out whether Oratest can be used as a diagnostic tool in assessing the caries activity by evaluating its relationship to the existing caries status and the salivary streptococcus mutans level. Materials and Methods: The study sample consists of 90 students divided into two groups. Group I (test group) and Group II (control group) consisting of 30 children for control group and 60 children for test group. The sampling of unstimulated saliva for the estimation of streptococcus mutans was done as per the method suggested by Kohler and Bratthall. The plates were then incubated. Rough surface colonies were identified as streptococcus mutans on a pre-determined area of the tip (approximately 1.5 cm2) were counted for each side of spatula pressed against mitis salivarius bacitracin agar using digital colony counter. The results were expressed in colony forming units (CFU). Oratest was carried out in the same patients after the collection of salivary sample for the microbiological method to evaluate the relationship between the two tests. Statistical Analysis Used: The tests used were ANOVA, Pearson Chi-square test, Pearson′s correlation analysis, Mann-Whitney U test and Student′s independent t-test. Results: In the control group and test group, when the streptococcus mutans count (CFU) and Oratest time (minutes) were correlated using Pearson′s correlation analysis, the streptococcus mutans counts was found to be in a statistically significant negative linear relationship with the Oratest time. When the caries status of the children, participated in the test group were correlated with mutans count (CFU) and Oratest time, caries status were found to be in a statistically significant positive linear relationship with streptococcus mutans count and in a significant negative linear relationship with Oratest time. Conclusions: The test proved to be a simple, inexpensive and rapid technique for assessing caries activity since a significant relationship exists clinically with caries status and microbiologically with the streptococcus mutans count of the individual. PMID:23946577

  18. Analysis of trend in temperature and rainfall time series of an Indian arid region: comparative evaluation of salient techniques

    NASA Astrophysics Data System (ADS)

    Machiwal, Deepesh; Gupta, Ankit; Jha, Madan Kumar; Kamble, Trupti

    2018-04-01

    This study investigated trends in 35 years (1979-2013) temperature (maximum, Tmax and minimum, Tmin) and rainfall at annual and seasonal (pre-monsoon, monsoon, post-monsoon, and winter) scales for 31 grid points in a coastal arid region of India. Box-whisker plots of annual temperature and rainfall time series depict systematic spatial gradients. Trends were examined by applying eight tests, such as Kendall rank correlation (KRC), Spearman rank order correlation (SROC), Mann-Kendall (MK), four modified MK tests, and innovative trend analysis (ITA). Trend magnitudes were quantified by Sen's slope estimator, and a new method was adopted to assess the significance of linear trends in MK-test statistics. It was found that the significant serial correlation is prominent in the annual and post-monsoon Tmax and Tmin, and pre-monsoon Tmin. The KRC and MK tests yielded similar results in close resemblance with the SROC test. The performance of two modified MK tests considering variance-correction approaches was found superior to the KRC, MK, modified MK with pre-whitening, and ITA tests. The performance of original MK test is poor due to the presence of serial correlation, whereas the ITA method is over-sensitive in identifying trends. Significantly increasing trends are more prominent in Tmin than Tmax. Further, both the annual and monsoon rainfall time series have a significantly increasing trend of 9 mm year-1. The sequential significance of linear trend in MK test-statistics is very strong (R 2 ≥ 0.90) in the annual and pre-monsoon Tmin (90% grid points), and strong (R 2 ≥ 0.75) in monsoon Tmax (68% grid points), monsoon, post-monsoon, and winter Tmin (respectively 65, 55, and 48% grid points), as well as in the annual and monsoon rainfalls (respectively 68 and 61% grid points). Finally, this study recommends use of variance-corrected MK test for the precise identification of trends. It is emphasized that the rising Tmax may hamper crop growth due to enhanced metabolic-activities and shortened crop-duration. Likewise, increased Tmin may result in lesser crop and biomass yields owing to the increased respiration.

  19. Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

    NASA Technical Reports Server (NTRS)

    Mikes, F.; Mowrey, C.; Reis, E.

    1985-01-01

    Results of lap shear tests of various silane primers are presented in graphs and tables. The OH-absorption of these primers (FTIR area values) are correlated with the lap shear tests of coated panels.

  20. Multivariate pattern analysis of fMRI data reveals deficits in distributed representations in schizophrenia

    PubMed Central

    Yoon, Jong H.; Tamir, Diana; Minzenberg, Michael J.; Ragland, J. Daniel; Ursu, Stefan; Carter, Cameron S.

    2009-01-01

    Background Multivariate pattern analysis is an alternative method of analyzing fMRI data, which is capable of decoding distributed neural representations. We applied this method to test the hypothesis of the impairment in distributed representations in schizophrenia. We also compared the results of this method with traditional GLM-based univariate analysis. Methods 19 schizophrenia and 15 control subjects viewed two runs of stimuli--exemplars of faces, scenes, objects, and scrambled images. To verify engagement with stimuli, subjects completed a 1-back matching task. A multi-voxel pattern classifier was trained to identify category-specific activity patterns on one run of fMRI data. Classification testing was conducted on the remaining run. Correlation of voxel-wise activity across runs evaluated variance over time in activity patterns. Results Patients performed the task less accurately. This group difference was reflected in the pattern analysis results with diminished classification accuracy in patients compared to controls, 59% and 72% respectively. In contrast, there was no group difference in GLM-based univariate measures. In both groups, classification accuracy was significantly correlated with behavioral measures. Both groups showed highly significant correlation between inter-run correlations and classification accuracy. Conclusions Distributed representations of visual objects are impaired in schizophrenia. This impairment is correlated with diminished task performance, suggesting that decreased integrity of cortical activity patterns is reflected in impaired behavior. Comparisons with univariate results suggest greater sensitivity of pattern analysis in detecting group differences in neural activity and reduced likelihood of non-specific factors driving these results. PMID:18822407

  1. Urdu translation of the Hamilton Rating Scale for Depression: Results of a validation study.

    PubMed

    Hashmi, Ali M; Naz, Shahana; Asif, Aftab; Khawaja, Imran S

    2016-01-01

    To develop a standardized validated version of the Hamilton Rating Scale for Depression (HAM-D) in Urdu. After translation of the HAM-D into the Urdu language following standard guidelines, the final Urdu version (HAM-D-U) was administered to 160 depressed outpatients. Inter-item correlation was assessed by calculating Cronbach alpha. Correlation between HAM-D-U scores at baseline and after a 2-week interval was evaluated for test-retest reliability. Moreover, scores of two clinicians on HAM-D-U were compared for inter-rater reliability. For establishing concurrent validity, scores of HAM-D-U and BDI-U were compared by using Spearman correlation coefficient. The study was conducted at Mayo Hospital, Lahore, from May to December 2014. The Cronbach alpha for HAM-D-U was 0.71. Composite scores for HAM-D-U at baseline and after a 2-week interval were also highly correlated with each other (Spearman correlation coefficient 0.83, p-value < 0.01) indicating good test-retest reliability. Composite scores for HAM-D-U and BDI-U were positively correlated with each other (Spearman correlation coefficient 0.85, p < 0.01) indicating good concurrent validity. Scores of two clinicians for HAM-D-U were also positively correlated (Spearman correlation coefficient 0.82, p-value < 0.01) indicated good inter-rater reliability. The HAM-D-U is a valid and reliable instrument for the assessment of Depression. It shows good inter-rater and test-retest reliability. The HAM-D-U can be a tool either for clinical management or research.

  2. Experimental Evaluation of Stagnation Point Collection Efficiency of the NACA 0012 Swept Wing Tip

    NASA Technical Reports Server (NTRS)

    Tsao, Jen-Ching; Kreeger, Richard E.

    2010-01-01

    This paper presents the experimental work of a number of icing tests conducted in the Icing Research Tunnel at NASA Glenn Research Center to develop a test method for measuring the local collection efficiency of an impinging cloud at the leading edge of a NACA 0012 swept wing and with the data obtained to further calibrate a proposed correlation for such impingement efficiency calculation as a function of the modified inertia parameter and the sweep angle. The preliminary results showed that there could be some limitation of the test method due to the ice erosion problem when encountered, and also found that, for conditions free of such problem, the stagnation point collection efficiency measurement for sweep angles up to 45 could be well approximated by the proposed correlation. Further evaluation of this correlation is recommended in order to assess its applicability for swept-wing icing scaling analysis.

  3. Neuropsychological and MMPI correlates of patients' future employment characteristics.

    PubMed

    Newnan, O S; Heaton, R K; Lehman, R A

    1978-04-01

    Previous research has suggested that patients' neuropsychological test scores correlate not only with neurologic status but also with their success in coping with some of the demands of daily living. This study investigated the utility of such laboratory test scores in predicting several vocational variables. Patients who had recieved neuropsychological evaluations were recontacted and questioned about their employment over the previous 6 mo. Of the 78 individuals who participated, 25 had been chronically unemployed. The remaining 53 were asked about job stability, hours worked, and wages earned, and were administered the Minnsota Job Requirements Questionnaire. Patients' scores on the Halstead-Reitan Battery, the WAIS and the MMPI were highly correlated with employment status (employed or chronically unemployed), income, and skills required on the jobs held. The results suggest that these tests may have clinical utility in assessing patients' employability, as well as the types of jobs for which they are suited.

  4. Assessing the significance of global and local correlations under spatial autocorrelation: a nonparametric approach.

    PubMed

    Viladomat, Júlia; Mazumder, Rahul; McInturff, Alex; McCauley, Douglas J; Hastie, Trevor

    2014-06-01

    We propose a method to test the correlation of two random fields when they are both spatially autocorrelated. In this scenario, the assumption of independence for the pair of observations in the standard test does not hold, and as a result we reject in many cases where there is no effect (the precision of the null distribution is overestimated). Our method recovers the null distribution taking into account the autocorrelation. It uses Monte-Carlo methods, and focuses on permuting, and then smoothing and scaling one of the variables to destroy the correlation with the other, while maintaining at the same time the initial autocorrelation. With this simulation model, any test based on the independence of two (or more) random fields can be constructed. This research was motivated by a project in biodiversity and conservation in the Biology Department at Stanford University. © 2014, The International Biometric Society.

  5. Wire Crimp Termination Verification Using Ultrasonic Inspection

    NASA Technical Reports Server (NTRS)

    Perey, Daniel F.; Cramer, K. Elliott; Yost, William T.

    2007-01-01

    The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed.

  6. Forced knee extension test is a manual test that correlates with the unstable feelings of patients with ACL injury before and after reconstruction.

    PubMed

    Shirasawa, Shinichi; Koga, Hideyuki; Horie, Masafumi; Nakamura, Tomomasa; Watanabe, Toshifumi; Sekiya, Ichiro; Muneta, Takeshi

    2016-12-01

    To investigate fear in patients with anterior cruciate ligament (ACL) injury before and after reconstruction, a forced knee extension (FKE) test was performed. The correlation of the test results was evaluated with the subjective function, sports performance and objective parameters. The study included 102 patients with unilateral ACL reconstruction using a semitendinosus tendon with full clinical evaluation. This study was retrospective and determined the longitudinal results of the FKE test and investigated the effects on the subjective and objective outcomes at 2years. Preoperatively, 47% of patients showed positive FKE tests. The number of positive FKE tests was 31% at six months and 15% at 24months after ACL reconstruction. At two years, there were statistically significant differences between the FKE test positives and negatives regarding both subjective knee recovery (P=0.0095) and sports performance (P=0.0006). A new manual test, called the forced knee extension test, for fear in patients with ACL injury before and after reconstruction was introduced. The apprehension remained positive in 15% of the patients two years after ACL reconstruction, which affected subjective recovery of knee function and sports performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Critical evaluation of a badminton-specific endurance test.

    PubMed

    Fuchs, Michael; Faude, Oliver; Wegmann, Melissa; Meyer, Tim

    2014-03-01

    To overcome the limitations of traditional 1-dimensional fitness tests in analyzing physiological properties of badminton players, a badminton-specific endurance test (BST) was created. This study aimed at analyzing the influence of various fitness dimensions on BST performance. 18 internationally competing male German badminton players (22.4 ± 3.2 y, 79.2 ± 7.7 kg, 1.84 ± 0.06 m, world-ranking position [WRP] 21-501) completed a straight-sprint test, a change-of-direction speed test, various jump tests (countermovement jump, drop jump, standing long jump), a multistage running test (MST), and the BST. During this on-court field test players have to respond to a computerized sign indicating direction and speed of badminton-specific movements by moving into the corresponding corners. Significant correlations were found between performance in MST and BST (individual anaerobic threshold [IAT], r = .63, P = .005; maximum velocity [Vmax], r = .60, P = .009). A negative correlation (r = -.59, P = .014) was observed between IAT in BST and drop-jump contact time. No further associations between performance indices could be detected. Apart from a small portion explained by MST results (IAT, R2 = .40; Vmax, R2 = .36), the majority of BST performance cannot be explained by the determined physiological correlates. Moreover, it was impossible to predict the WRP of a player on the basis of BST results (r = -.15, P = .55). Neither discipline-specific performance nor basic physiological properties were appropriately reflected by a BST in elite badminton players. This does not substantiate its validity for regular use as a testing tool. However, it may be useful for monitoring on-court training sessions.

  8. Frontal parenchymal atrophy measures in multiple sclerosis.

    PubMed

    Locatelli, Laura; Zivadinov, Robert; Grop, Attilio; Zorzon, Marino

    2004-10-01

    The aim of this study was to establish whether, in a cross-sectional study, the normalized measures of whole and regional brain atrophy correlate better with tests assessing the cognitive function than the absolute brain atrophy measures. The neuropsychological performances and disability have been assessed in 39 patients with relapsing-remitting multiple sclerosis (MS). T1- and T2-lesion load (LL) of total brain and frontal lobes (FLs) were measured using a reproducible semiautomated technique. The whole brain volume and the regional brain parenchymal volume (RBPV) of FLs were obtained using a computerized interactive program, which incorporates semiautomated and automated segmentation processes. Normalized measures of brain atrophy, i.e., brain parenchymal fraction (BPF) and regional brain parenchymal fraction (RBPF) of FLs, were calculated. The scan-rescan, inter- and intrarater coefficient of variation (COV) and intraclass correlation coefficient (ICC) have been estimated. The RBPF of FLs showed an acceptable level of reproducibility which ranged from 1.7% for intrarater variability to 3.2% for scan-rescan variability. The mean ICC was 0.88 (CI 0.82-0.93). The RBPF of FLs demonstrated stronger magnitudes of correlation with neuropsychological functioning, disability and quantitative MRI lesion measures than RBPV. These differences were statistically significant: P<0.001 for Stroop Color Word Interference test, P<0.001 for Paced Auditory Serial Addition Test, P=0.04 for Standard Raven Progressive Matrices, P=0.049 for Expanded Disability Status Scale, P=0.01 for T2-LL of FLs and P<0.001 for T1-LL of FLs. BPF demonstrated significant correlations with tests assessing cognitive functions, whereas BPAV did not. The correlation analysis results were supported by the results of multiple regression analysis which showed that only the normalized brain atrophy measures were associated with tests exploring the cognitive functions. These data suggest that RBPF is a reproducible and sensitive method for measuring frontal parenchymal atrophy. The normalized measures of whole and regional brain parenchymal atrophy should be preferred to absolute measures in future studies that correlate neuropsychological performances and brain atrophy measures in patients with MS.

  9. Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer

    NASA Technical Reports Server (NTRS)

    Abdel-Magid, Becky M.; Gates, Thomas S.

    2000-01-01

    Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.

  10. Relationship between performance test and body composition/physical strength characteristic in sprint canoe and kayak paddlers

    PubMed Central

    Hamano, Saki; Ochi, Eisuke; Tsuchiya, Yosuke; Muramatsu, Erina; Suzukawa, Kazuhiro; Igawa, Shoji

    2015-01-01

    Objective Canoe sprint is divided into canoe and kayak. The difference between the two competitions is in physical performance. The aim of the present study was to compare and investigate the relationship between physical characteristics and fitness between the two canoe sprint competitors. Methods Subjects were 11 canoe paddlers (C) and 12 kayak paddlers (K). They underwent anthropometric characteristics, body composition and fitness tests, and 120 s all-out tests using a canoe and kayak ergometer. The unpaired t-test was used to test for significant differences between disciplines, while Pearson’s correlation coefficient was used to examine the association between each measurement item and the performance test. Results The age, height, body mass, body mass index, and total body fat were, C: 20.6±0.9 yr, 172.8±5.2 cm, 70.8±7.8 kg, 23.7±1.9, 14.4%±3.5%; and K: 19.7±1.2 yr, 172.8±5.3 cm, 69.5±7.8 kg, 23.2±2.1, 12.1%±3.6%, respectively. No significant differences were seen in any of the items for physical characteristics or fitness between C and K. A correlation analysis of performance tests and each measurement item revealed a positive correlation with low-speed isokinetic knee extension and flexion strength for C only (extension: r=0.761; flexion: r=0.784; P<0.01). In addition, performance tests were positively correlated with the circumference of arm (upper arm: r=0.876; forearm: r=0.820; P<0.01) and lower limb (thigh: r=0.781; calf: r=0.753; P<0.01) in C and with height (r=0.549, P<0.05), arm span (r=0.639, P<0.05), and leg length (r=0.621, P<0.01) in K. Conclusion We suggest that the factors correlating with the performance test differ depending on the competitions. PMID:26150737

  11. Relationship Between Change of Direction, Speed and Power in Male and Female National Olympic Team Handball Athletes.

    PubMed

    Pereira, Lucas A; Nimphius, Sophia; Kobal, Ronaldo; Kitamura, Katia; Turisco, Luiz A L; Orsi, Rita C; Cal Abad, César Cs; Loturco, Irineu

    2018-02-22

    The aims of this study were to (1) assess the relationship between selected speed-power related abilities (determined by 20-m sprint, unloaded countermovement and squat jumps [CMJ and SJ] and loaded jump squat [JS]) and performance in two distinct change of direction (COD) protocols (Zigzag and T-Test), and (2) determine the magnitude of difference between female and male Brazilian National Olympic Team handball athletes. Fifteen male and twenty-three female elite handball athletes volunteered to perform the following assessments: SJ and CMJ; Zigzag and T-Test; 20-m sprint with 5-, 10-, and 20-m splits, and mean propulsive power (MPP) in JS. Pearson product moment correlation (P< 0.05) was performed to determine the relationship between the COD tests (Zigzag and T-test) and speed-power measures (sprint, SJ, CMJ and JS). The differences between male and female performances were determined using the magnitude-based inference. Moderate to very large significant correlations were observed between both COD tests and the speed-power abilities. Further, male athletes demonstrated likely to almost certainly higher performances than female athletes in all assessed variables. The results of the current study suggest that different speed-power qualities are strongly correlated to the performance obtained in various COD assessments (r values varying from 0.38 to 0.84 and from 0.34 to 0.84 for correlations between speed and power tests with Zigzag and T-Test, respectively). However, the level of these associations can vary greatly, according to the mechanical demands of each respective COD task. Whilst COD tests may be difficult to implement during competitive seasons, due to the strong correlations presented herein, the regular use of vertical jump tests with these athletes seems to be an effective and applied alternative. Furthermore, it might be inferred that the proper development of loaded and unloaded jump abilities has potential for improving the physical qualities related to COD performance in handball athletes.

  12. SPIROMETRY IN SCHOOLCHILDREN FOR FIELD STUDIES: DOES TESTING ON DIFFERENT DAYS CHANGE THE RESULT OF THE EXAM?

    PubMed Central

    Scalco, Janaina Cristina; Minsky, Rafaela Coelho; Schivinski, Camila Isabel Santos

    2017-01-01

    ABSTRACT Objective: To analyze if there is variation in the results of spirometry performed by healthy schoolchildren on different days. Methods: Cross-sectional study with healthy schoolchildren aged 7 to 12 years old, in Florianópolis, Santa Catarina, Southern Brazil. Prepubescent children, non-athletes, born at full term, without cardiorespiratory, rheumatic, musculoskeletal, neurological and visual or hearing deficit were included. The child’s health was assessed by a health questionnaire and by the survey International Study of Asthma and Allergies in Childhood. The spirometric test was performed on 3 different days, not exceeding the interval of 15 days between the first and last exams, following the guidelines of the American Thoracic Society. The absolute values and percentages of predicted values of forced vital capacity, forced volume in the first second and peak expiratory flow were analyzed. Statistical analysis was performed using the Shapiro-Wilk normality test followed by one-way analysis of variance or Friedman test and by Bonferroni’s post-hoc test for multiple parametric comparisons. Also, the intraclass correlation coefficient was applied to compare results on the same patients on the different tested days. Results: Twenty-two children were analyzed, with a mean age of 9.3±1.1 years. All the spirometric parameters showed a reduction in absolute value after the first exam, but without significant difference. Regarding reproducibility of spirometry results, the tests presented intraclass correlation coefficient >0.70. Conclusions: There was no change in the results of spirometry performed by healthy schoolchildren on three different days. PMID:29160411

  13. Prevalence of maedi-visna infection in culled ewes in Alberta

    PubMed Central

    Fournier, Dominique; Campbell, John R.

    2006-01-01

    Abstract Maedi-visna (MV) is a relatively common chronic infection of sheep in North America resulting in economic loss to the sheep industry. The objectives of this study were to: 1) measure the prevalence of MV infection in culled ewes in Alberta, by histologic examination (lungs and udder) and serologic testing using an agar gel immunodiffusion (AGID) test, 2) examine any geographic differences in its prevalence in the province, 3) evaluate the level of agreement between histopathologic examination and serologic testing, 4) grade the lesions and correlate the serologic results with the presence of severe histological lesions, and 5) correlate the presence of histological lesions in the lungs and udder in the same animal. Based on histologic findings, the prevalence of MV was 26.8%, compared with 13.0% using serologic testing. There were no significant geographical differences in prevalence, fair agreement (kappa = 42.0%) between histopathologic and serologic results, and poor agreement (kappa = 11.5%) between the presence of lung and udder histological lesions within the same animal. This study indicates that MV is relatively common in culled ewes in Alberta, with no significant geographic variation. The poor sensitivity of the AGID test, compared with histologic examination, should be taken into consideration when interpreting serologic results. PMID:16734372

  14. The value of a non-sport-specific motor test battery in predicting performance in young female gymnasts.

    PubMed

    Vandorpe, Barbara; Vandendriessche, Joric B; Vaeyens, Roel; Pion, Johan; Lefevre, Johan; Philippaerts, Renaat M; Lenoir, Matthieu

    2012-01-01

    Gymnastics talent identification focuses on the identification of young gymnasts who display characteristics for potential success in the future. The aim of this study was to identify which current performance characteristics are related to performance in competition 2 years later. Twenty-three female gymnasts aged 7-8 years completed a multidimensional test battery measuring anthropometric, physical, and coordinative characteristics and were technically evaluated by expert coaches. Two years later, the all-around competition results of those gymnasts now participating in elite (n = 12) and sub-elite (n = 11) competition were obtained. None of the initial measurements significantly correlated with the results of the sub-elite gymnasts 2 years later. For the elite gymnasts, a non-sport-specific motor test battery correlated strongly with the competition result, with more than 40% of the variation in competition performance being explained by the result on that test 2 years earlier. Neither the coaches' judgement nor the anthropometric and physical characteristics were sensitive enough to predict performance. A motor coordination test might be valuable in the early identification of gymnasts, as its discriminative and predictive qualities might be sufficiently powerful for selection within a relatively homogeneous population of gymnasts exhibiting similar anthropometric and physical profiles.

  15. A need for a standardization in anaerobic digestion experiments? Let's get some insight from meta-analysis and multivariate analysis.

    PubMed

    Lavergne, Céline; Jeison, David; Ortega, Valentina; Chamy, Rolando; Donoso-Bravo, Andrés

    2018-09-15

    An important variability in the experimental results in anaerobic digestion lab test has been reported. This study presents a meta-analysis coupled with multivariate analysis aiming to assess the impact of this experimental variability in batch and continuous operation at mesophilic and thermophilic anaerobic digestion of waste activated sludge. An analysis of variance showed that there was no significant difference between mesophilic and thermophilic conditions in both continuous and batch conditions. Concerning the operation mode, the values of methane yield were significantly higher in batch experiment than in continuous reactors. According to the PCA, for both cases, the methane yield is positive correlated to the temperature rises. Interestingly, in the batch experiments, the higher the volatile solids in the substrate was, the lowest was the methane production, which is correlated to experimental flaws when setting up those tests. In continuous mode, unlike the batch test, the methane yield is strongly (positively) correlated to the organic content of the substrate. Experimental standardization, above all, in batch conditions are urgently necessary or move to continuous experiments for reporting results. The modeling can also be a source of disturbance in batch test. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Comparative study of computerized dynamic posturography and the SwayStar system in healthy subjects.

    PubMed

    Faraldo-García, Ana; Santos-Pérez, Sofía; Crujeiras, Rosa; Labella-Caballero, Torcuato; Soto-Varela, Andrés

    2012-03-01

    For healthy subjects, posturography and SwayStar™ results are basically comparable, when they are obtained under the same sensory stimulation conditions. However, the management of the information and the mathematical analyses in the two systems are not comparable. Postural control represents man's ability to maintain the center of pressures inside the limits of stability. Posturography is a set of techniques that objectively studies and quantifies the postural control. The present study analyzed the different parameters of the dynamic computerized posturography and SwayStar systems related to balance, to determine whether the results of the two systems in the same healthy subject are equivalent. Seventy healthy individuals, with a mean age of 44.9 years, were homogeneously divided into seven age groups. Postural studies with a Neurocom(®) Smart Balance Master posturography platform (sensorial organization test), with the SwayStar(®) system (14 tests), and another sensorial organization test were recorded simultaneously with the two posturographs. The Pearson correlation test was used for the statistical study (p < 0.05). Comparison of the independent records showed correlation only in the Romberg position with eyes closed on a normal surface and in the Romberg position with open eyes on moving/foam surface. We found correlation for all conditions when simultaneously recorded.

  17. Statistical test for ΔρDCCA cross-correlation coefficient

    NASA Astrophysics Data System (ADS)

    Guedes, E. F.; Brito, A. A.; Oliveira Filho, F. M.; Fernandez, B. F.; de Castro, A. P. N.; da Silva Filho, A. M.; Zebende, G. F.

    2018-07-01

    In this paper we propose a new statistical test for ΔρDCCA, Detrended Cross-Correlation Coefficient Difference, a tool to measure contagion/interdependence effect in time series of size N at different time scale n. For this proposition we analyzed simulated and real time series. The results showed that the statistical significance of ΔρDCCA depends on the size N and the time scale n, and we can define a critical value for this dependency in 90%, 95%, and 99% of confidence level, as will be shown in this paper.

  18. Application of Computational Fluid Dynamics (CFD) in transonic wind-tunnel/flight-test correlation

    NASA Technical Reports Server (NTRS)

    Murman, E. M.

    1982-01-01

    The capability for calculating transonic flows for realistic configurations and conditions is discussed. Various phenomena which were modeled are shown to have the same order of magnitude on the influence of predicted results. It is concluded that CFD can make the following contributions to the task of correlating wind tunnel and flight test data: some effects of geometry differences and aeroelastic distortion can be predicted; tunnel wall effects can be assessed and corrected for; and the effects of model support systems and free stream nonuniformities can be modeled.

  19. Spherical roller bearing analysis. SKF computer program SPHERBEAN. Volume 3: Program correlation with full scale hardware tests

    NASA Technical Reports Server (NTRS)

    Kleckner, R. J.; Rosenlieb, J. W.; Dyba, G.

    1980-01-01

    The results of a series of full scale hardware tests comparing predictions of the SPHERBEAN computer program with measured data are presented. The SPHERBEAN program predicts the thermomechanical performance characteristics of high speed lubricated double row spherical roller bearings. The degree of correlation between performance predicted by SPHERBEAN and measured data is demonstrated. Experimental and calculated performance data is compared over a range in speed up to 19,400 rpm (0.8 MDN) under pure radial, pure axial, and combined loads.

  20. Toxicity testing of urinary catheters.

    PubMed

    Talja, M; Andersson, L C; Ruutu, M; Alfthan, O

    1985-10-01

    The tissue toxicity of 23 urinary catheter batches (6 latex and 2 non-latex brands) was tested in vitro and in vivo. In vitro, a human T-cell leukemia line (JM) was cultured in the presence of different concentrations of eluates made from the catheters. The cytotoxicity of the eluates was assessed from their ability to inhibit DNA synthesis measured by incorporation of 3H-thymidine. In vivo, two methods were used. Strips of catheters were implanted into the rabbit dorsal muscle and pieces of catheters were implanted into the rat peritoneal cavity. After four days, the foreign body reaction, type of inflammation and necrosis were quantified macroscopically and by light microscopy. The results of the in vitro cytotoxicity test were correlated with those of in vivo methods. The rat peritoneal implantation test correlated better with the cell culture test (P less than 0.01) than with the rabbit muscle implantation test (P less than 0.05). Based on the clinical experience of urethral stricture complications caused by urinary catheters, catheters yielding eluate which at 30% dilution inhibited 50% DNA synthesis were regarded as toxic. According to this, the rabbit muscle implantation test was not reliable in testing the tissue toxicity of urinary catheters, while the cell culture test was quantitative and seemed to correlate with both the rat peritoneal implantation test and with the clinical complications observed.

  1. Validity and reliability of a new tool to evaluate handwriting difficulties in Parkinson’s disease

    PubMed Central

    Nackaerts, Evelien; Heremans, Elke; Smits-Engelsman, Bouwien C. M.; Broeder, Sanne; Vandenberghe, Wim; Bergmans, Bruno; Nieuwboer, Alice

    2017-01-01

    Background Handwriting in Parkinson’s disease (PD) features specific abnormalities which are difficult to assess in clinical practice since no specific tool for evaluation of spontaneous movement is currently available. Objective This study aims to validate the ‘Systematic Screening of Handwriting Difficulties’ (SOS-test) in patients with PD. Methods Handwriting performance of 87 patients and 26 healthy age-matched controls was examined using the SOS-test. Sixty-seven patients were tested a second time within a period of one month. Participants were asked to copy as much as possible of a text within 5 minutes with the instruction to write as neatly and quickly as in daily life. Writing speed (letters in 5 minutes), size (mm) and quality of handwriting were compared. Correlation analysis was performed between SOS outcomes and other fine motor skill measurements and disease characteristics. Intrarater, interrater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Spearman correlation coefficient. Results Patients with PD had a smaller (p = 0.043) and slower (p<0.001) handwriting and showed worse writing quality (p = 0.031) compared to controls. The outcomes of the SOS-test significantly correlated with fine motor skill performance and disease duration and severity. Furthermore, the test showed excellent intrarater, interrater and test-retest reliability (ICC > 0.769 for both groups). Conclusion The SOS-test is a short and effective tool to detect handwriting problems in PD with excellent reliability. It can therefore be recommended as a clinical instrument for standardized screening of handwriting deficits in PD. PMID:28253374

  2. Results of the second Round Robin on opening-load measurement conducted by ASTM Task Group E24.04.04 on crack closure measurement and analysis

    NASA Technical Reports Server (NTRS)

    Phillips, E. P.

    1993-01-01

    A second experimental Round Robin on the measurement of the crack opening load in fatigue crack growth tests has been completed by the ASTM Task Group E24.04.04 on Crack Closure Measurement and Analysis. Fourteen laboratories participated in the testing of aluminum alloy compact tension specimens. Opening-load measurements were made at three crack lengths during constant Delta K, constant stress ratio tests by most of the participants. Four participants made opening-load measurements during threshold tests. All opening-load measurements were based on the analysis of specimens compliance behavior, where the displacement/strain was measured either at the crack mouth or the mid-height back face location. The Round Robin data were analyzed for opening load using two non-subjective analysis methods: the compliance offset and the correlation coefficient methods. The scatter in the opening load results was significantly reduced when some of the results were excluded from the analysis population based on an accept/reject criterion for raw data quality. The compliance offset and correlation coefficient opening load analysis methods produced similar results for data populations that had been screened to eliminate poor quality data.

  3. Determination of Rolling-Element Fatigue Life From Computer Generated Bearing Tests

    NASA Technical Reports Server (NTRS)

    Vlcek, Brian L.; Hendricks, Robert C.; Zaretsky, Erwin V.

    2003-01-01

    Two types of rolling-element bearings representing radial loaded and thrust loaded bearings were used for this study. Three hundred forty (340) virtual bearing sets totaling 31400 bearings were randomly assembled and tested by Monte Carlo (random) number generation. The Monte Carlo results were compared with endurance data from 51 bearing sets comprising 5321 bearings. A simple algebraic relation was established for the upper and lower L(sub 10) life limits as function of number of bearings failed for any bearing geometry. There is a fifty percent (50 percent) probability that the resultant bearing life will be less than that calculated. The maximum and minimum variation between the bearing resultant life and the calculated life correlate with the 90-percent confidence limits for a Weibull slope of 1.5. The calculated lives for bearings using a load-life exponent p of 4 for ball bearings and 5 for roller bearings correlated with the Monte Carlo generated bearing lives and the bearing data. STLE life factors for bearing steel and processing provide a reasonable accounting for differences between bearing life data and calculated life. Variations in Weibull slope from the Monte Carlo testing and bearing data correlated. There was excellent agreement between percent of individual components failed from Monte Carlo simulation and that predicted.

  4. Quantification of brake creep groan in vehicle tests and its relation with stick-slip obtained in laboratory tests

    NASA Astrophysics Data System (ADS)

    Neis, P. D.; Ferreira, N. F.; Poletto, J. C.; Matozo, L. T.; Masotti, D.

    2016-05-01

    This paper describes the development of a methodology for assessing and correlating stick-slip and brake creep groan. For doing that, results of tribotests are compared to data obtained in vehicle tests. A low velocity and a linear reduction in normal force were set for the tribotests. The vehicle tests consisted of subjecting a sport utility vehicle to three different ramp slopes. Creep groan events were measured by accelerometers placed on the brake calipers. The root mean square of the acceleration signal (QRMS parameter) was shown to be able to measure the creep groan severity resulting from the vehicle tests. Differences in QRMS were observed between front-rear and left-right wheels for all tested materials. Frequency spectrum analysis of the acceleration revealed that the wheel side and material type do not cause any significant shift in the creep groan frequency. QRMS measured in the vehicle tests presented good correlation with slip power (SP) summation. For this reason, SP summation may represent the "creep groan propensity" of brake materials. Thus, the proposed tribotest method can be utilized to predict the creep groan severity of brake materials in service.

  5. The impact of stroke on emotional intelligence

    PubMed Central

    2010-01-01

    Background Emotional intelligence (EI) is important for personal, social and career success and has been linked to the frontal anterior cingulate, insula and amygdala regions. Aim To ascertain which stroke lesion sites impair emotional intelligence and relation to current frontal assessment measurements. Methods One hundred consecutive, non aphasic, independently functioning patients post stroke were evaluated with the Bar-On emotional intelligence test, "known as the Emotional Quotient Inventory (EQ-i)" and frontal tests that included the Wisconsin Card Sorting Test (WCST) and Frontal Systems Behavioral Inventory (FRSBE) for correlational validity. The results of a screening, bedside frontal network syndrome test (FNS) and NIHSS to document neurological deficit were also recorded. Lesion location was determined by the Cerefy digital, coxial brain atlas. Results After exclusions (n = 8), patients tested (n = 92, mean age 50.1, CI: 52.9, 47.3 years) revealed that EQ-i scores were correlated (negatively) with all FRSBE T sub-scores (apathy, disinhibition, executive, total), with self-reported scores correlating better than family reported scores. Regression analysis revealed age and FRSBE total scores as the most influential variables. The WCST error percentage T score did not correlate with the EQ-i scores. Based on ANOVA, there were significant differences among the lesion sites with the lowest mean EQ-i scores associated with temporal (71.5) and frontal (87.3) lesions followed by subtentorial (91.7), subcortical gray (92.6) and white (95.2) matter, and the highest scores associated with parieto-occipital lesions (113.1). Conclusions 1) Stroke impairs EI and is associated with apathy, disinhibition and executive functioning. 2) EI is associated with frontal, temporal, subcortical and subtentorial stroke syndromes. PMID:21029468

  6. The application of soccer performance testing protocols to the non-elite player.

    PubMed

    Siegler, J; Robergs, R; Weingart, H

    2006-03-01

    The application of performance testing for the evaluation of non-elite soccer players has received little attention. The purpose of this investigation was to use tests developed for elite soccer players to evaluate performance in non-elite soccer players and compare performance test results between elite (literature) and non-elite (data) players. Thirteen male soccer players volunteered to participate. The tests included a treadmill VO2max test, 20 m sprint, vertical jump (VJ), 30 s Wingate cycle ergometer test, the Loughborough Intermittent Shuttle Test (LIST), and 2 20-m multi-stage shuttle runs to exhaustion (fatigue test). Actual VO2max (absolute and relative) scores were correlated with the estimated VO2max scores (fatigue test), 20 m sprint, VJ, and 30 s Wingate using a Pearson's product-moment correlation. A paired t-test was conducted on the fatigue test trials. Non-significant relationships were observed between actual VO2max scores and estimated VO2max from the fatigue test (absolute and relative terms). Non-significant relationships were also observed between peak and average power output (Wingate), 20 m sprint, and VJ. Mean heart rates (HRs) throughout the LIST was 165+/-7 bpm, which represented 88% of HRmax. The results of this study demonstrate that to elicit physiological differences between elite and non-elite players, assessment must include both an aerobic and anaerobic component.

  7. Consumer vinegar test for determining calcium disintegration.

    PubMed

    Mason, N A; Patel, J D; Dressman, J B; Shimp, L A

    1992-09-01

    A consumer test and standardized methods were compared for measuring the disintegration of calcium tablets, and the disintegration results were compared with results of dissolution testing to determine the ability of the consumer test of disintegration to predict bioavailability of calcium. Disintegration of 17 calcium supplement products, in tablet form, was studied in Simulated Gastric Fluid Test Solution, USP, without pepsin (GF), in distilled water, and in white distilled vinegar. For disintegration testing with GF and with distilled water, six tablets of each product were placed in an apparatus and immersed in the solution at 37 degrees C for 60 minutes. Six tablets of each product were tested in 200 mL of vinegar at room temperature for 30 minutes. Disintegration was determined by visual observation. Seven products were tested for dissolution in GF or water. Three samples of each product were tested at intervals over 120 minutes for calcium content. Results of testing with an ion-selective electrode were converted to milligrams and compared with the calcium content of the tablets (as claimed on the package label). The mean disintegration times of various calcium products in vinegar ranged from 1.8 to greater than 30 minutes. The mean time in distilled water and GF ranged from 1.6 to greater than 60 minutes and from 1.0 to greater than 60 minutes, respectively. Results were in agreement in 87% to 93% of cases between the consumer vinegar test and the standardized disintegration test methods, a significant correlation. No correlation was found between disintegration time and the extent of dissolution. The disintegration and dissolution of commercially available calcium tablets was highly variable.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Facing the facts: The Runx2 gene is associated with variation in facial morphology in primates.

    PubMed

    Ritzman, Terrence B; Banovich, Nicholas; Buss, Kaitlin P; Guida, Jennifer; Rubel, Meagan A; Pinney, Jennifer; Khang, Bao; Ravosa, Matthew J; Stone, Anne C

    2017-10-01

    The phylogenetic and adaptive factors that cause variation in primate facial form-including differences among the major primate clades and variation related to feeding and/or social behavior-are relatively well understood. However, comparatively little is known about the genetic mechanisms that underlie diversity in facial form in primates. Because it is essential for osteoblastic differentiation and skeletal development, the runt-related transcription factor 2 (Runx2) is one gene that may play a role in these genetic mechanisms. Specifically, polymorphisms in the QA ratio (determined by the ratio of the number of polyglutamines to polyalanines in one functional domain of Runx2) have been shown to be correlated with variation in facial length and orientation in other mammal groups. However, to date, the relationship between variation in this gene and variation in facial form in primates has not been explicitly tested. To test the hypothesis that the QA ratio is correlated with facial form in primates, the current study quantified the QA ratio, facial length, and facial angle in a sample of 33 primate species and tested for correlation using phylogenetic generalized least squares. The results indicate that the QA ratio of the Runx2 gene is positively correlated with variation in relative facial length in anthropoid primates. However, no correlation was found in strepsirrhines, and there was no correlation between facial angle and the QA ratio in any groups. These results suggest that, in primates, the QA ratio of the Runx2 gene may play a role in modulating facial size, but not facial orientation. This study therefore provides important clues about the genetic and developmental mechanisms that may underlie variation in facial form in primates. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Test Anxiety among College Students with Specific Reading Disability (Dyslexia): Nonverbal Ability and Working Memory as Predictors

    ERIC Educational Resources Information Center

    Nelson, Jason M.; Lindstrom, Will; Foels, Patricia A.

    2015-01-01

    Test anxiety and its correlates were examined with college students with and without specific reading disability (RD; n = 50 in each group). Results indicated that college students with RD reported higher test anxiety than did those without RD, and the magnitude of these differences was in the medium range on two test anxiety scales. Relative to…

  10. Preliminary Flight Results of the Microelectronics and Photonics Test Bed: NASA DR1773 Fiber Optic Data Bus Experiment

    NASA Technical Reports Server (NTRS)

    Jackson, George L.; LaBel, Kenneth A.; Marshall, Cheryl; Barth, Janet; Seidleck, Christina; Marshall, Paul

    1998-01-01

    NASA Goddard Spare Flight Center's (GSFC) Dual Rate 1773 (DR1773) Experiment on the Microelectronic and Photonic Test Bed (MPTB) has provided valuable information on the performance of the AS 1773 fiber optic data bus in the space radiation environment. Correlation of preliminary experiment data to ground based radiation test results show the AS 1773 bus is employable in future spacecraft applications requiring radiation tolerant communication links.

  11. Condensation heat transfer and pressure drop of R-410A in flat aluminum multi-port tubes

    NASA Astrophysics Data System (ADS)

    Kim, Nae-Hyun

    2018-02-01

    Brazed heat exchangers with aluminum flat multi-port tubes are being used as condensers of residential air-conditioners. In this study, R-410A condensation tests were conducted in four multi-port tubes having a range of hydraulic diameter (0.78 ≤ Dh ≤ 0.95 mm). The test range covered the mass flux from 100 to 400 kg/m2 s and the heat flux at 3 kW/m2, which are typical operating conditions of residential air conditioners. Results showed that both the heat transfer coefficient and the pressure drop increased as the hydraulic diameter decreased. The effect of hydraulic diameter on condensation heat transfer was much larger than the predictions of existing correlations for the range of investigation. Comparison of the data with the correlations showed that some macro-channel tube correlations and mini-channel tube correlations reasonably predicted the heat transfer coefficient. However, macro-channel correlations highly overpredicted the pressure drop data.

  12. Agreement Analysis: What He Said, She Said Versus You Said.

    PubMed

    Vetter, Thomas R; Schober, Patrick

    2018-06-01

    Correlation and agreement are 2 concepts that are widely applied in the medical literature and clinical practice to assess for the presence and strength of an association. However, because correlation and agreement are conceptually distinct, they require the use of different statistics. Agreement is a concept that is closely related to but fundamentally different from and often confused with correlation. The idea of agreement refers to the notion of reproducibility of clinical evaluations or biomedical measurements. The intraclass correlation coefficient is a commonly applied measure of agreement for continuous data. The intraclass correlation coefficient can be validly applied specifically to assess intrarater reliability and interrater reliability. As its name implies, the Lin concordance correlation coefficient is another measure of agreement or concordance. In undertaking a comparison of a new measurement technique with an established one, it is necessary to determine whether they agree sufficiently for the new to replace the old. Bland and Altman demonstrated that using a correlation coefficient is not appropriate for assessing the interchangeability of 2 such measurement methods. They in turn described an alternative approach, the since widely applied graphical Bland-Altman Plot, which is based on a simple estimation of the mean and standard deviation of differences between measurements by the 2 methods. In reading a medical journal article that includes the interpretation of diagnostic tests and application of diagnostic criteria, attention is conventionally focused on aspects like sensitivity, specificity, predictive values, and likelihood ratios. However, if the clinicians who interpret the test cannot agree on its interpretation and resulting typically dichotomous or binary diagnosis, the test results will be of little practical use. Such agreement between observers (interobserver agreement) about a dichotomous or binary variable is often reported as the kappa statistic. Assessing the interrater agreement between observers, in the case of ordinal variables and data, also has important biomedical applicability. Typically, this situation calls for use of the Cohen weighted kappa. Questionnaires, psychometric scales, and diagnostic tests are widespread and increasingly used by not only researchers but also clinicians in their daily practice. It is essential that these questionnaires, scales, and diagnostic tests have a high degree of agreement between observers. It is therefore vital that biomedical researchers and clinicians apply the appropriate statistical measures of agreement to assess the reproducibility and quality of these measurement instruments and decision-making processes.

  13. Effect of creep in titanium alloy Ti-6Al-4V at elevated temperature on aircraft design and flight test

    NASA Technical Reports Server (NTRS)

    Jenkins, J. M.

    1984-01-01

    Short-term compressive creep tests were conducted on three titanium alloy Ti-6Al-4V coupons at three different stress levels at a temperature of 714 K (825 F). The test data were compared to several creep laws developed from tensile creep tests of available literature. The short-term creep test data did not correlate well with any of the creep laws obtained from available literature. The creep laws themselves did not correlate well with each other. Short-term creep does not appear to be very predictable for titanium alloy Ti-6Al-4V. Aircraft events that result in extreme, but short-term temperature and stress excursions for this alloy should be approached cautiously. Extrapolations of test data and creep laws suggest a convergence toward predictability in the longer-term situation.

  14. The Use of Time Series Analysis and t Tests with Serially Correlated Data Tests.

    ERIC Educational Resources Information Center

    Nicolich, Mark J.; Weinstein, Carol S.

    1981-01-01

    Results of three methods of analysis applied to simulated autocorrelated data sets with an intervention point (varying in autocorrelation degree, variance of error term, and magnitude of intervention effect) are compared and presented. The three methods are: t tests; maximum likelihood Box-Jenkins (ARIMA); and Bayesian Box Jenkins. (Author/AEF)

  15. Standardized performance tests of collectors of solar thermal energy - A flat-plate copper collector with parallel mylar striping

    NASA Technical Reports Server (NTRS)

    Johnson, S. M.

    1976-01-01

    Basic test results are reported for a flat plate solar collector whose performance was determined in a solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  16. Standardized performance tests of collectors of solar thermal energy: An evacuated flatplate copper collector with a serpentine flow distribution

    NASA Technical Reports Server (NTRS)

    Johnson, S. M.

    1976-01-01

    Basic test results are given for a flat plate solar collector whose performance was determined in the NASA-Lewis solar simulator. The collector was tested over ranges of inlet temperatures, fluxes and one coolant flow rate. Collector efficiency is correlated in terms of inlet temperature and flux level.

  17. On the insignificance of Herschel's sunspot correlation

    NASA Astrophysics Data System (ADS)

    Love, Jeffrey J.

    2013-08-01

    We examine William Herschel's hypothesis that solar-cycle variation of the Sun's irradiance has a modulating effect on the Earth's climate and that this is, specifically, manifested as an anticorrelation between sunspot number and the market price of wheat. Since Herschel first proposed his hypothesis in 1801, it has been regarded with both interest and skepticism. Recently, reports have been published that either support Herschel's hypothesis or rely on its validity. As a test of Herschel's hypothesis, we seek to reject a null hypothesis of a statistically random correlation between historical sunspot numbers, wheat prices in London and the United States, and wheat farm yields in the United States. We employ binary-correlation, Pearson-correlation, and frequency-domain methods. We test our methods using a historical geomagnetic activity index, well known to be causally correlated with sunspot number. As expected, the measured correlation between sunspot number and geomagnetic activity would be an unlikely realization of random data; the correlation is "statistically significant." On the other hand, measured correlations between sunspot number and wheat price and wheat yield data would be very likely realizations of random data; these correlations are "insignificant." Therefore, Herschel's hypothesis must be regarded with skepticism. We compare and contrast our results with those of other researchers. We discuss procedures for evaluating hypotheses that are formulated from historical data.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poloski, Adam P.; Adkins, Harold E.; Abrefah, John

    The WTP pipe plugging issue, as stated by the External Flowsheet Review Team (EFRT) Executive Summary, is as follows: “Piping that transports slurries will plug unless it is properly designed to minimize this risk. This design approach has not been followed consistently, which will lead to frequent shutdowns due to line plugging.” A strategy was employed to perform critical-velocity tests on several physical simulants. Critical velocity is defined as the point where a stationary bed of particles deposits on the bottom of a straight horizontal pipe during slurry transport operations. Results from the critical velocity testing provide an indication ofmore » slurry stability as a function of fluid rheological properties and transport conditions. The experimental results are compared to the WTP design guide on slurry transport velocity in an effort to confirm minimum waste velocity and flushing velocity requirements as established by calculations and critical line velocity correlations in the design guide. The major findings of this testing is discussed below. Experimental results indicate that the use of the Oroskar and Turian (1980) correlation in the design guide is conservative—Slurry viscosity has a greater affect on particles with a large surface area to mass ratio. The increased viscous forces on these particles result in a decrease in predicted critical velocities from this traditional industry derived equations that focus on particles large than 100 μm in size. Since the Hanford slurry particles generally have large surface area to mass ratios, the reliance on such equations in the Hall (2006) design guide is conservative. Additionally, the use of the 95% percentile particle size as an input to this equation is conservative. However, test results indicate that the use of an average particle density as an input to the equation is not conservative. Particle density has a large influence on the overall result returned by the correlation. Lastly, the viscosity correlation used in the WTP design guide has been shown to be inaccurate for Hanford waste feed materials. The use of the Thomas (1979) correlation in the design guide is not conservative—In cases where 100% of the particles are smaller than 74 μm or particles are considered to be homogeneous due to yield stress forces suspending the particles the homogeneous fraction of the slurry can be set to 100%. In such cases, the predicted critical velocity based on the conservative Oroskar and Turian (1980) correlation is reduced to zero and the design guide returns a value from the Thomas (1979) correlation. The measured data in this report show that the Thomas (1979) correlation predictions often fall below that measured experimental values. A non-Newtonian deposition velocity design guide should be developed for the WTP— Since the WTP design guide is limited to Newtonian fluids and the WTP expects to process large quantities of such materials, the existing design guide should be modified address such systems. A central experimental finding of this testing is that the flow velocity required to reach turbulent flow increases with slurry rheological properties due to viscous forces dampening the formation of turbulent eddies. The flow becomes dominated by viscous forces rather than turbulent eddies. Since the turbulent eddies necessary for particle transport are not present, the particles will settle when crossing this boundary called the transitional deposition boundary. This deposition mechanism should be expected and designed for in the WTP.« less

  19. Validity and Reliability of Wii Fit Balance Board for the Assessment of Balance of Healthy Young Adults and the Elderly

    PubMed Central

    Chang, Wen-Dien; Chang, Wan-Yi; Lee, Chia-Lun; Feng, Chi-Yen

    2013-01-01

    [Purpose] Balance is an integral part of human ability. The smart balance master system (SBM) is a balance test instrument with good reliability and validity, but it is expensive. Therefore, we modified a Wii Fit balance board, which is a convenient balance assessment tool, and analyzed its reliability and validity. [Subjects and Methods] We recruited 20 healthy young adults and 20 elderly people, and administered 3 balance tests. The correlation coefficient and intraclass correlation of both instruments were analyzed. [Results] There were no statistically significant differences in the 3 tests between the Wii Fit balance board and the SBM. The Wii Fit balance board had a good intraclass correlation (0.86–0.99) for the elderly people and positive correlations (r = 0.58–0.86) with the SBM. [Conclusions] The Wii Fit balance board is a balance assessment tool with good reliability and high validity for elderly people, and we recommend it as an alternative tool for assessing balance ability. PMID:24259769

  20. Route Learning Impairment in Temporal Lobe Epilepsy

    PubMed Central

    Bell, Brian D.

    2012-01-01

    Memory impairment on neuropsychological tests is relatively common in temporal lobe epilepsy (TLE) patients. But memory rarely has been evaluated in more naturalistic settings. This study assessed TLE (n = 19) and control (n = 32) groups on a real-world route learning (RL) test. Compared to the controls, the TLE group committed significantly more total errors across the three RL test trials. RL errors correlated significantly with standardized auditory and visual memory and visual-perceptual test scores in the TLE group. In the TLE subset for whom hippocampal data were available (n = 14), RL errors also correlated significantly with left hippocampal volume. This is one of the first studies to demonstrate real-world memory impairment in TLE patients and its association with both mesial temporal lobe integrity and standardized memory test performance. The results support the ecological validity of clinical neuropsychological assessment. PMID:23041173

  1. Accuracy of indocyanine green pulse spectrophotometry clearance test for liver function prediction in transplanted patients

    PubMed Central

    Hsieh, Chung-Bao; Chen, Chung-Jueng; Chen, Teng-Wei; Yu, Jyh-Cherng; Shen, Kuo-Liang; Chang, Tzu-Ming; Liu, Yao-Chi

    2004-01-01

    AIM: To investigate whether the non-invasive real-time Indocynine green (ICG) clearance is a sensitive index of liver viability in patients before, during, and after liver transplantation. METHODS: Thirteen patients were studied, two before, three during, and eight following liver transplantation, with two patients suffering acute rejection. The conventional invasive ICG clearance test and ICG pulse spectrophotometry non-invasive real-time ICG clearance test were performed simultaneously. Using linear regression analysis we tested the correlation between these two methods. The transplantation condition of these patients and serum total bilirubin (T. Bil), alanine aminotransferase (ALT), and platelet count were also evaluated. RESULTS: The correlation between these two methods was excellent (r2 = 0.977). CONCLUSION: ICG pulse spectrophotometry clearance is a quick, non-invasive, and reliable liver function test in transplantation patients. PMID:15285026

  2. Correlation of ASTM D4833 and D6241 geotextile puncture test methods and results for use on WisDOT projects.

    DOT National Transportation Integrated Search

    2017-04-01

    Geotextiles are commonly used in pavements, earth retaining structures, and landfills, as well as other geotechnical applications. Various : tests are conducted to evaluate and classify geotextiles to determine their suitability for different applica...

  3. A multi-gene phylogeny of Cephalopoda supports convergent morphological evolution in association with multiple habitat shifts in the marine environment

    PubMed Central

    2012-01-01

    Background The marine environment is comprised of numerous divergent organisms living under similar selective pressures, often resulting in the evolution of convergent structures such as the fusiform body shape of pelagic squids, fishes, and some marine mammals. However, little is known about the frequency of, and circumstances leading to, convergent evolution in the open ocean. Here, we present a comparative study of the molluscan class Cephalopoda, a marine group known to occupy habitats from the intertidal to the deep sea. Several lineages bear features that may coincide with a benthic or pelagic existence, making this a valuable group for testing hypotheses of correlated evolution. To test for convergence and correlation, we generate the most taxonomically comprehensive multi-gene phylogeny of cephalopods to date. We then create a character matrix of habitat type and morphological characters, which we use to infer ancestral character states and test for correlation between habitat and morphology. Results Our study utilizes a taxonomically well-sampled phylogeny to show convergent evolution in all six morphological characters we analyzed. Three of these characters also correlate with habitat. The presence of an autogenic photophore (those relying upon autonomous enzymatic light reactions) is correlated with a pelagic habitat, while the cornea and accessory nidamental gland correlate with a benthic lifestyle. Here, we present the first statistical tests for correlation between convergent traits and habitat in cephalopods to better understand the evolutionary history of characters that are adaptive in benthic or pelagic environments, respectively. Discussion Our study supports the hypothesis that habitat has influenced convergent evolution in the marine environment: benthic organisms tend to exhibit similar characteristics that confer protection from invasion by other benthic taxa, while pelagic organisms possess features that facilitate crypsis and communication in an environment lacking physical refuges. Features that have originated multiple times in distantly related lineages are likely adaptive for the organisms inhabiting a particular environment: studying the frequency and evolutionary history of such convergent characters can increase understanding of the underlying forces driving ecological and evolutionary transitions in the marine environment. PMID:22839506

  4. [Predictive power of working memory task for reading comprehension: an investigation using reading span test].

    PubMed

    Morishita, Masanao; Kondo, Hirohito; Ashida, Kayo; Otsuka, Yuki; Osaka, Naoyuki

    2007-02-01

    This study investigated the crucial factor mediating a correlation between performance of reading span test (RST) and reading comprehension. In the research literature on this issue, one of the remaining controversial points is whether the similarity of sentence processing between RST and comprehension contributes to the correlation. In this study, four RST conditions were created by the combination of two factors: relatedness of stimulus sentences (related or unrelated with each other) and focus of target words (focus or non-focus with respect to sentence meaning). If the correlation is mediated by the similarity of sentence processing, RST performance of related and focus condition, which was most akin to comprehension, would have higher correlation with reading comprehension than other conditions. However, as a result of correlation analysis based on data from ninety-six participants, no such evidence was obtained. On the other hand, RST performance of unrelated conditions that were supposed to strongly require attention control showed significant correlation with reading comprehension. These findings are discussed in terms of the contribution of attention control and short-term memory to performing RST and reading comprehension.

  5. Fish allergy in atopic children.

    PubMed

    Peng, Y H; Shyur, S D; Chang, C L; Lai, C L; Chu, S H; Wu, W C; Wu, C Y

    2001-12-01

    The prevalence of fish allergy among 11 atopic children with elevated levels of specific immunoglobulin (Ig) E for cod was determined. None of the children had a history of fish allergy. All of the children had asthma and allergic rhinitis and 5 of them had also atopic dermatitis. The children underwent allergy skin tests (codfish, tuna, catfish, salmon, flounder, and bass), specific IgE tests (salmon, trout, tuna, eel, and mackerel), and food challenge tests. Skin tests in cod-specific IgE-positive children were positive for codfish in 4 children, tuna in 2, catfish in 2, salmon in 6, flounder in one, and bass in 2. Three children had elevated specific IgE for salmon, 5 for trout, 8 for tuna, 4 for eel, and 4 for mackerel. Oral fish challenge with 10 g of fish did not result in positive reaction in any of the children. In conclusion, a positive food challenge test provided the only definitive confirmation of fish allergy, whereas positive allergy skin tests or positive specific IgE tests were less reliable. Skin tests and in vitro specific IgE assays were not correlated with clinical symptoms of fish allergy, and the results of these 2 tests did not correlate with each other in this study.

  6. Clinical Assessment of a New Caries Activity Test Using Dental Plaque Acidogenicity in Children under Three Years of Age.

    PubMed

    Lee, Hyo-Seol; Lee, Eun-Song; Kang, Si-Mook; Lee, Jae-Ho; Choi, Hyung-Jun; Kim, Baek-Il

    The aim of this study was to assess the validity of a new caries activity test that uses dental plaque acidogenicity in children with deciduous dentition. Ninety-two children under the age of three years old underwent clinical examination using the dft index and examinations with two caries activity tests. Plaque samples for the new Cariview(®) test and the saliva sample for the conventional Dentocult SM(®) test were collected, incubated, and scored according to each manufacturers' instruction. The data were analysed using ANOVA and Spearman correlation analyses to evaluate the relationships between the test results and the caries experience. The mean dft index of all of the subjects was 4.73, and 17.4% of the subjects were caries-free. The levels of caries risk based on the new Cariview test score significantly increased with the caries experience (p < 0.01). The test results revealed a stronger correlation with caries indices (dft and dt index) than the conventional SM colony counting method (r = 0.43, r = 0.39, p < 0.01). The new caries activity test to analyse the acidogenic potential of whole microorganisms from dental plaques can be used to evaluate caries risk in children with deciduous teeth.

  7. Engineering Properties and Correlation Analysis of Fiber Cementitious Materials

    PubMed Central

    Lin, Wei-Ting; Wu, Yuan-Chieh; Cheng, An; Chao, Sao-Jeng; Hsu, Hui-Mi

    2014-01-01

    This study focuses on the effect of the amount of silica fume addition and volume fraction of steel fiber on the engineering properties of cementitious materials. Test variables include dosage of silica fume (5% and 10%), water/cement ratio (0.35 and 0.55) and steel fiber dosage (0.5%, 1.0% and 2.0%). The experimental results included: compressive strength, direct tensile strength, splitting tensile strength, surface abrasion and drop-weight test, which were collected to carry out the analysis of variance to realize the relevancy and significance between material parameters and those mechanical properties. Test results illustrate that the splitting tensile strength, direct tensile strength, strain capacity and ability of crack-arresting increase with increasing steel fiber and silica fume dosages, as well as the optimum mixture of the fiber cementitious materials is 5% replacement silica fume and 2% fiber dosage. In addition, the Pearson correlation coefficient was conducted to evaluate the influence of the material variables and corresponds to the experiment result. PMID:28788256

  8. Measurement of the Correlation and Coherence Lengths in Boundary Layer Flight Data

    NASA Technical Reports Server (NTRS)

    Palumbo, Daniel L.

    2011-01-01

    Wall pressure data acquired during flight tests at several flight conditions are analyzed and the correlation and coherence lengths of the data reported. It is shown how the frequency bandwidth of the analysis biases the correlation length and how the convection of the flow acts to reduce the coherence length. Coherence lengths measured in the streamwise direction appear much longer than would be expected based on classical results for flow over a flat plat.

  9. Assessing the Applicability of Digital Image Correlation (DIC) Technique in Tensile Testing of Fabric Composites

    DTIC Science & Technology

    2013-02-01

    glass composites and 318.51±6.77 MPa for the basalt fibers . On average, the S2 glass composite had a higher modulus of elasticity of 12.94±0.84 GPa...5. The progression of strain on the tool side of the tensile sample. 9 The results of the tensile testing for the basalt fibers are shown in...reported modulus values shown in table 1. Figure 6. Results of the tensile testing of the basalt fiber composites. 3.1.2 Results of the Line

  10. Frequency-domain preprocessing and directional correlation-based feature extraction for classification of the buried objects using GPR B-scan data

    NASA Astrophysics Data System (ADS)

    Bahadirlar, Yildirim; Kaplan, Gulay B.

    2004-09-01

    A new preprocessing and feature extracting approach for classification of non-metallic buried objects are aimed using GPR B-scan data. A frequency-domain adaptive filter without a reference channel effectively removes the background signal resulting mostly from the discontinuity on the air-to-ground path of the electromagnetic waves. The filter only needs average of the first five A-scans as the reference signal for this elimination, and also serves for masking of the B-scan in the frequency-domain. A preprocessed GPR data with significantly suppressed clutter is then obtained by precisely positioning the Hanning window in the frequency-domain. A directional correlation function defined over a B-scan frame gives distinctive curves of buried objects. The main axis of directional correlation, on which the pivotal correlating pixels and short lines of pixels being correlated are considered, makes an angle to the scanning direction of the B-scan. This form of correlation is applied to the frame from the left-hand and the right-hand side and two over-plotted curves are obtained. Nine measures as features emphasizing directional signatures are extracted from these curves. Nine-element feature vectors are applied to the two-layer Artificial Neural Network and preliminary results over test set are promising to continue to comprehensive training and testing processes.

  11. Medical University admission test: a confirmatory factor analysis of the results.

    PubMed

    Luschin-Ebengreuth, Marion; Dimai, Hans P; Ithaler, Daniel; Neges, Heide M; Reibnegger, Gilbert

    2016-05-01

    The Graz Admission Test has been applied since the academic year 2006/2007. The validity of the Test was demonstrated by a significant improvement of study success and a significant reduction of dropout rate. The purpose of this study was a detailed analysis of the internal correlation structure of the various components of the Graz Admission Test. In particular, the question investigated was whether or not the various test parts constitute a suitable construct which might be designated as "Basic Knowledge in Natural Science." This study is an observational investigation, analyzing the results of the Graz Admission Test for the study of human medicine and dentistry. A total of 4741 applicants were included in the analysis. Principal component factor analysis (PCFA) as well as techniques from structural equation modeling, specifically confirmatory factor analysis (CFA), were employed to detect potential underlying latent variables governing the behavior of the measured variables. PCFA showed good clustering of the science test parts, including also text comprehension. A putative latent variable "Basic Knowledge in Natural Science," investigated by CFA, was indeed shown to govern the response behavior of the applicants in biology, chemistry, physics, and mathematics as well as text comprehension. The analysis of the correlation structure of the various test parts confirmed that the science test parts together with text comprehension constitute a satisfactory instrument for measuring a latent construct variable "Basic Knowledge in Natural Science." The present results suggest the fundamental importance of basic science knowledge for results obtained in the framework of the admission process for medical universities.

  12. Cross-correlation between the 170 GHz survey map and the COBE differential microwave radiometer first-year maps

    NASA Technical Reports Server (NTRS)

    Ganga, Ken; Cheng, ED; Meyer, Stephan; Page, Lyman

    1993-01-01

    This letter describes results of a cross-correlation between the 170 GHz partial-sky survey, made with a 3.8 deg beam balloon-borne instrument, and the COBE DMR 'Fit Technique' reduced galaxy all-sky map with a beam of 7 deg. The strong correlation between the data sets implies that the observed structure is consistent with thermal variations in a 2.7 K emitter. A chi-square analysis applied to the correlation function rules out the assumption that there is no structure in either of the two maps. A second test shows that if the DMR map has structure but the 170 GHz map does not, the probability of obtaining the observed correlation is small. Further analyses support the assumption that both maps have structure and that the 170 GHz-DMR cross-correlation is consistent with the analogous DMR correlation function. Maps containing various combinations of noise and Harrison-Zel'dovich power spectra are simulated and correlated to reinforce the result. The correlation provides compelling evidence that both instruments have observed fluctuations consistent with anisotropies in the cosmic microwave background.

  13. Rapid susceptibility testing of fungi by flow cytometry using vital staining.

    PubMed Central

    Wenisch, C; Linnau, K F; Parschalk, B; Zedtwitz-Liebenstein, K; Georgopoulos, A

    1997-01-01

    A 1-h assay for antifungal susceptibility testing measuring the impairment of fungal metabolic activity was developed. Yeast viability was analyzed by flow cytometry with a novel fluorescent probe, FUN-1, which emits a red fluorescence when the yeast is metabolically active. For nine Candida albicans strains tested, this method yielded results comparable to those obtained by the standard M27 procedure for amphotericin B, flucytosine, fluconazole, and ketoconazole. Whether the flow cytometry antifungal susceptibility test results correlate with the in vivo activities of the drugs remains to determined. PMID:8968873

  14. Wavelet filtered shifted phase-encoded joint transform correlation for face recognition

    NASA Astrophysics Data System (ADS)

    Moniruzzaman, Md.; Alam, Mohammad S.

    2017-05-01

    A new wavelet-filtered-based Shifted- phase-encoded Joint Transform Correlation (WPJTC) technique has been proposed for efficient face recognition. The proposed technique uses discrete wavelet decomposition for preprocessing and can effectively accommodate various 3D facial distortions, effects of noise, and illumination variations. After analyzing different forms of wavelet basis functions, an optimal method has been proposed by considering the discrimination capability and processing speed as performance trade-offs. The proposed technique yields better correlation discrimination compared to alternate pattern recognition techniques such as phase-shifted phase-encoded fringe-adjusted joint transform correlator. The performance of the proposed WPJTC has been tested using the Yale facial database and extended Yale facial database under different environments such as illumination variation, noise, and 3D changes in facial expressions. Test results show that the proposed WPJTC yields better performance compared to alternate JTC based face recognition techniques.

  15. Joint demosaicking and zooming using moderate spectral correlation and consistent edge map

    NASA Astrophysics Data System (ADS)

    Zhou, Dengwen; Dong, Weiming; Chen, Wengang

    2014-07-01

    The recently published joint demosaicking and zooming algorithms for single-sensor digital cameras all overfit the popular Kodak test images, which have been found to have higher spectral correlation than typical color images. Their performance perhaps significantly degrades on other datasets, such as the McMaster test images, which have weak spectral correlation. A new joint demosaicking and zooming algorithm is proposed for the Bayer color filter array (CFA) pattern, in which the edge direction information (edge map) extracted from the raw CFA data is consistently used in demosaicking and zooming. It also moderately utilizes the spectral correlation between color planes. The experimental results confirm that the proposed algorithm produces an excellent performance on both the Kodak and McMaster datasets in terms of both subjective and objective measures. Our algorithm also has high computational efficiency. It provides a better tradeoff among adaptability, performance, and computational cost compared to the existing algorithms.

  16. Further Study of the Choice of Anchor Tests in Equating

    ERIC Educational Resources Information Center

    Trierweiler, Tammy J.; Lewis, Charles; Smith, Robert L.

    2016-01-01

    In this study, we describe what factors influence the observed score correlation between an (external) anchor test and a total test. We show that the anchor to full-test observed score correlation is based on two components: the true score correlation between the anchor and total test, and the reliability of the anchor test. Findings using an…

  17. Rearing in enriched environment increases parvalbumin-positive small neurons in the amygdala and decreases anxiety-like behavior of male rats

    PubMed Central

    2013-01-01

    Background Early life experiences including physical exercise, sensory stimulation, and social interaction can modulate development of the inhibitory neuronal network and modify various behaviors. In particular, alteration of parvalbumin-expressing neurons, a gamma-aminobutyric acid (GABA)ergic neuronal subpopulation, has been suggested to be associated with psychiatric disorders. Here we investigated whether rearing in enriched environment could modify the expression of parvalbumin-positive neurons in the basolateral amygdala and anxiety-like behavior. Results Three-week-old male rats were divided into two groups: those reared in an enriched environment (EE rats) and those reared in standard cages (SE rats). After 5 weeks of rearing, the EE rats showed decreased anxiety-like behavior in an open field than the SE rats. Under another anxiogenic situation, in a beam walking test, the EE rats more quickly traversed an elevated narrow beam. Anxiety-like behavior in the open field was significantly and negatively correlated with walking time in the beam-walking test. Immunohistochemical tests revealed that the number of parvalbumin-positive neurons significantly increased in the basolateral amygdala of the EE rats than that of the SE rats, while the number of calbindin-D28k-positive neurons did not change. These parvalbumin-positive neurons had small, rounded soma and co-expressed the glutamate decarboxylase (GAD67). Furthermore, the number of parvalbumin-positive small cells in the basolateral amygdala tended to positively correlate with emergence in the center arena of the open field and negatively correlated with walking time in the beam walking test. Conclusion Rearing in the enriched environment augmented the number of parvalbumin-containing specific inhibitory neuron in the basolateral amygdala, but not that of calbindin-containing neuronal phenotype. Furthermore, the number of parvalbumin-positive small neurons in the basolateral amygdala was negatively correlated with walking time in the beam walking test and tended to be positively correlated with activity in the center arena in the open field test. The results suggest that rearing in the enriched environment augmented parvalbumin-positive specific neurons in the basolateral amygdala, which induced behavioral plasticity that was reflected by a decrease in anxiety-like behavior in anxiogenic situations. PMID:23347699

  18. A general statistical test for correlations in a finite-length time series.

    PubMed

    Hanson, Jeffery A; Yang, Haw

    2008-06-07

    The statistical properties of the autocorrelation function from a time series composed of independently and identically distributed stochastic variables has been studied. Analytical expressions for the autocorrelation function's variance have been derived. It has been found that two common ways of calculating the autocorrelation, moving-average and Fourier transform, exhibit different uncertainty characteristics. For periodic time series, the Fourier transform method is preferred because it gives smaller uncertainties that are uniform through all time lags. Based on these analytical results, a statistically robust method has been proposed to test the existence of correlations in a time series. The statistical test is verified by computer simulations and an application to single-molecule fluorescence spectroscopy is discussed.

  19. Performance of exchange-correlation functionals in density functional theory calculations for liquid metal: A benchmark test for sodium.

    PubMed

    Han, Jeong-Hwan; Oda, Takuji

    2018-04-14

    The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.

  20. Performance of exchange-correlation functionals in density functional theory calculations for liquid metal: A benchmark test for sodium

    NASA Astrophysics Data System (ADS)

    Han, Jeong-Hwan; Oda, Takuji

    2018-04-01

    The performance of exchange-correlation functionals in density-functional theory (DFT) calculations for liquid metal has not been sufficiently examined. In the present study, benchmark tests of Perdew-Burke-Ernzerhof (PBE), Armiento-Mattsson 2005 (AM05), PBE re-parameterized for solids, and local density approximation (LDA) functionals are conducted for liquid sodium. The pair correlation function, equilibrium atomic volume, bulk modulus, and relative enthalpy are evaluated at 600 K and 1000 K. Compared with the available experimental data, the errors range from -11.2% to 0.0% for the atomic volume, from -5.2% to 22.0% for the bulk modulus, and from -3.5% to 2.5% for the relative enthalpy depending on the DFT functional. The generalized gradient approximation functionals are superior to the LDA functional, and the PBE and AM05 functionals exhibit the best performance. In addition, we assess whether the error tendency in liquid simulations is comparable to that in solid simulations, which would suggest that the atomic volume and relative enthalpy performances are comparable between solid and liquid states but that the bulk modulus performance is not. These benchmark test results indicate that the results of liquid simulations are significantly dependent on the exchange-correlation functional and that the DFT functional performance in solid simulations can be used to roughly estimate the performance in liquid simulations.

Top