Sample records for cortical button fixation

  1. Revision ulnar collateral ligament reconstruction using a suspension button fixation technique.

    PubMed

    Lee, Gregory H; Limpisvasti, Orr; Park, Maxwell C; McGarry, Michelle H; Yocum, Lewis A; Lee, Thay Q

    2010-03-01

    Revision ulnar collateral ligament reconstruction remains a challenging problem. The objective of this study was to biomechanically evaluate an ulnar collateral ligament reconstruction technique using a suspension button fixation technique that can be used even in the case of ulnar cortical bone loss. An ulnar suspension fixation technique for ulnar collateral ligament reconstruction can restore elbow kinematics and demonstrate failure strength comparable to that of currently available techniques. Controlled laboratory study. Nine pairs of cadaveric elbows were dissected free of soft tissue and potted. After simulating ulnar cortical bone loss, ulnar collateral ligament reconstruction was performed in 1 elbow of each pair using palmaris longus autograft and a 30-mm RetroButton suspended from the far (lateralmost) ulnar cortex. A docking technique was used for humeral fixation of the graft. Elbow valgus angle was quantified using a Microscribe 3DLX digitizer at multiple elbow flexion angles. Valgus angle was measured with the ulnar collateral ligament intact, transected, and reconstructed. In addition, load-to-failure testing was performed in 1 elbow of each pair. Release of the ulnar collateral ligament caused a significant increase in valgus angle at each flexion angle tested (P < .002). Reconstructed elbows demonstrated no significant differences in valgus angle from the intact elbow at all flexion angles tested. Load-to-failure tests showed that reconstructed elbows had an ultimate torque (10.3 + or - 5.7 N x m) significantly less than intact elbows (26.4 + or - 10.6 N x m) (P = .001). Ulnar collateral ligament reconstruction using a suspension button fixation technique reliably restored elbow kinematics to the intact state. Load-to-failure testing demonstrated comparable fixation strength to several historic controls of primary reconstruction techniques despite the simulated ulnar cortical bone loss. Ulnar collateral ligament reconstruction using a suspension button fixation technique can be considered in the case of ulnar cortical bone loss in a primary or revision setting.

  2. Biomechanics of the Proximal Radius Following Drilling of the Bicipital Tuberosity to Mimic Cortical Button Distal Biceps Repair Technique.

    PubMed

    Oak, Nikhil R; Lien, John R; Brunfeldt, Alexander; Lawton, Jeffrey N

    2018-05-01

    A fracture through the proximal radius is a theoretical concern after cortical button distal biceps fixation in an active patient. The permanent, nonossified cortical defect and medullary tunnel is at risk during a fall eliciting rotational and compressive forces. We hypothesized that during simulated torsion and compression, in comparison with unaltered specimens, the cortical button distal biceps repair model would have decreased torsional and compressive strength and would fracture in the vicinity of the bicipital tuberosity bone tunnel. Sixteen fourth-generation composite radius Sawbones models were used in this controlled laboratory study. A bone tunnel was created through the bicipital tuberosity to mimic the exact bone tunnel, 8 mm near cortex and 3.2 mm far cortex, made for the BicepsButton distal biceps tendon repair. The radius was then prepared and mounted on either a torsional or compression testing device and compared with undrilled control specimens. Compression tests resulted in average failure loads of 9015.2 N in controls versus 8253.25 N in drilled specimens ( P = .074). Torsional testing resulted in an average failure torque of 27.3 Nm in controls and 19.3 Nm in drilled specimens ( P = .024). Average fracture angle was 35.1° in controls versus 21.1° in drilled. Gross fracture patterns were similar in compression testing; however, in torsional testing all fractures occurred through the bone tunnel in the drilled group. There are weaknesses in the vicinity of the bone tunnel in the proximal radius during biomechanical stress testing which may not be clinically relevant in nature. In cortical button fixation, distal biceps repairs creates a permanent, nonossified cortical defect with tendon interposed in the bone tunnel, which can alter the biomechanical properties of the proximal radius during compressive and torsional loading.

  3. Pectoralis Major Repair With Unicortical Button Fixation And Suture Tape.

    PubMed

    Sanchez, Anthony; Ferrari, Marcio B; Frangiamore, Salvatore J; Sanchez, George; Kruckeberg, Bradley M; Provencher, Matthew T

    2017-06-01

    Although injuries of the pectoralis major muscle are generally uncommon, ruptures of the pectoralis major are occasionally seen in younger, more active patients who participate in weightlifting activities. These injuries usually occur during maximal contraction of the muscle, while in extension and external rotation. In the case of a rupture, operative treatment is advocated especially in young, active patients regardless of the chronicity of the injury. Various surgical techniques for reattachment of the avulsed tendon have been described, but bone tunnel and suture anchor repair techniques are most widely used. In this Technical Note, we present our preferred technique for acute pectoralis major rupture repair involving use of cortical buttons for tendon stump-to-bone fixation.

  4. Radiographic failure and rates of re-operation after acromioclavicular joint reconstruction: a comparison of surgical techniques.

    PubMed

    Spencer, H T; Hsu, L; Sodl, J; Arianjam, A; Yian, E H

    2016-04-01

    To compare radiographic failure and re-operation rates of anatomical coracoclavicular (CC) ligament reconstructional techniques with non-anatomical techniques after chronic high grade acromioclavicular (AC) joint injuries. We reviewed chronic AC joint reconstructions within a region-wide healthcare system to identify surgical technique, complications, radiographic failure and re-operations. Procedures fell into four categories: (1) modified Weaver-Dunn, (2) allograft fixed through coracoid and clavicular tunnels, (3) allograft loop coracoclavicular fixation, and (4) combined allograft loop and synthetic cortical button fixation. Among 167 patients (mean age 38.1 years, (standard deviation (sd) 14.7) treated at least a four week interval after injury, 154 had post-operative radiographs available for analysis. Radiographic failure occurred in 33/154 cases (21.4%), with the lowest rate in Technique 4 (2/42 4.8%, p = 0.001). Half the failures occurred by six weeks, and the Kaplan-Meier survivorship at 24 months was 94.4% (95% confidence interval (CI) 79.6 to 98.6) for Technique 4 and 69.9% (95% CI 59.4 to 78.3) for the other techniques when combined. In multivariable survival analysis, Technique 4 had better survival than other techniques (Hazard Ratio 0.162, 95% CI 0.039 to 0.068, p = 0.013). Among 155 patients with a minimum of six months post-operative insurance coverage, re-operation occurred in 9.7% (15 patients). However, in multivariable logistic regression, Technique 4 did not reach a statistically significant lower risk for re-operation (odds ratio 0.254, 95% CI 0.05 to 1.3, p = 0.11). In this retrospective series, anatomical CC ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. Anatomical coracoclavicular ligament reconstruction using combined synthetic cortical button and allograft loop fixation had the lowest rate of radiographic failure. ©2016 The British Editorial Society of Bone & Joint Surgery.

  5. Suture Button Fixation Versus Syndesmotic Screws in Supination-External Rotation Type 4 Injuries: A Cost-Effectiveness Analysis.

    PubMed

    Neary, Kaitlin C; Mormino, Matthew A; Wang, Hongmei

    2017-01-01

    In stress-positive, unstable supination-external rotation type 4 (SER IV) ankle fractures, implant selection for syndesmotic fixation is a debated topic. Among the available syndesmotic fixation methods, the metallic screw and the suture button have been routinely compared in the literature. In addition to strength of fixation and ability to anatomically restore the syndesmosis, costs associated with implant use have recently been called into question. This study aimed to examine the cost-effectiveness of the suture button and determine whether suture button fixation is more cost-effective than two 3.5-mm syndesmotic screws not removed on a routine postoperative basis. Economic and decision analysis; Level of evidence, 2. Studies with the highest evidence levels in the available literature were used to estimate the hardware removal and failure rates for syndesmotic screws and suture button fixation. Costs were determined by examining the average costs for patients who underwent surgery for unstable SER IV ankle fractures at a single level-1 trauma institution. A decision analysis model that allowed comparison of the 2 fixation methods was developed. Using a 20% screw hardware removal rate and a 4% suture button hardware removal rate, the total cost for 2 syndesmotic screws was US$20,836 and the total effectiveness was 5.846. This yielded a total cost of $3564 per quality-adjusted life-year (QALY) over an 8-year time period. The total cost for suture button fixation was $19,354 and the total effectiveness was 5.904, resulting in a total cost of $3294 per QALY over the same time period. A sensitivity analysis was then conducted to assess suture button fixation costs as well as screw and suture button hardware removal rates. Other possible treatment scenarios were also examined, including 1 screw and 2 suture buttons for operative fixation of the syndesmosis. To become more cost-effective, the screw hardware removal rate would have to be reduced to less than 10%. Furthermore, fixation with a single suture button continued to be the dominant treatment strategy compared with 2 suture buttons, 1 screw, and 2 screws for syndesmotic fixation. This cost-effectiveness analysis suggests that for unstable SER IV ankle fractures, suture button fixation is more cost-effective than syndesmotic screws not removed on a routine basis. Suture button fixation was a dominant treatment strategy, because patients spent on average $1482 less and had a higher quality of life by 0.058 QALYs compared with patients who received fixation with 2 syndesmotic screws. Assuming that functional outcomes and failure rates were equivalent, screw fixation only became more cost-effective when the screw hardware removal rate was reduced to less than 10% or when the suture button cost exceeded $2000. In addition, fixation with a single suture button device proved more cost-effective than fixation with either 1 or 2 syndesmotic screws.

  6. Acromioclavicular joint dislocation: a Dog Bone button fixation alone versus Dog Bone button fixation augmented with acromioclavicular repair-a finite element analysis study.

    PubMed

    Sumanont, Sermsak; Nopamassiri, Supachoke; Boonrod, Artit; Apiwatanakul, Punyawat; Boonrod, Arunnit; Phornphutkul, Chanakarn

    2018-03-20

    Suspension suture button fixation was frequently used to treat acromioclavicular joint (ACJ) dislocation. However, there were many studies reporting about complications and residual horizontal instability after fixation. Our study compared the stability of ACJ after fixation between coracoclavicular (CC) fixation alone and CC fixation combined with ACJ repair by using finite element analysis (FEA). A finite element model was created by using CT images from the normal shoulder. The model 1 was CC fixation with suture button alone, and the model 2 was CC fixation with suture button combined with ACJ repair. Three different forces (50, 100, 200 N) applied to the model in three planes; inferior, anterior and posterior direction load to the acromion. The von Mises stress of the implants and deformation at ACJs was recorded. The ACJ repair in the model 2 could reduce the peak stress on the implant after applying the loading forces to the acromion which the ACJ repair could reduce the peak stress of the FiberWire at suture button about 90% when compared to model 1. And, the ACJ repair could reduce the deformation of the ACJ after applying the loading forces to the acromion in both vertical and horizontal planes. This FEA supports that the high-grade injuries of the ACJ should be treated with CC fixation combined with ACJ repair because this technique provides excellent stability in both vertical and horizontal planes and reduces stress to the suture button.

  7. [Effectiveness comparison of flexible fixation and rigid fixation in treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis].

    PubMed

    Li, Yuewei; Zhang, Minghui; Li, Xiaorong; Chen, Xiaoyong; Deng, Jianlong

    2017-07-01

    To compare the effectiveness of flexible fixation and rigid fixation in the treatment of ankle pronation-external rotation fractures with distal tibiofibular syndesmosis. A retrospective analysis was made on the clinical data of 50 patients with ankle pronation-external rotation fractures and distal tibiofibular syndesmosis treated between January 2013 and December 2015. Suture-button fixation was used in 23 patients (flexible fixation group) and cortical screw fixation in 27 patients (rigid fixation group). There was no significant difference in age, gender, weight, side, fracture type, and time from trauma to surgery between 2 groups ( P >0.05). The operation time, medial clear space (MCS), tibiofibular clear space (TFCS), tibiofibular overlap (TFO), American Orthopaedic Foot and Ankle Society (AOFAS) score, and Foot and Ankle Disability Index (FADI) score were compared between 2 groups. The operation time was (83.0±9.1) minutes in the flexible fixation group and was (79.6±13.1) minutes in the rigid fixation group, showing no significant difference ( t =1.052, P =0.265). All patients achieved healing of incision by first intention. The patients were followed up 12-20 months (mean, 14 months). The X-ray films showed good healing of fracture in 2 groups. There was no screw fracture, delayed union or nounion. The fracture healing time was (12.1±2.5) months in the flexible fixation group and was (11.3±3.2) months in the rigid fixation group, showing no significant difference between 2 groups ( t =1.024, P =0.192). Reduction loss occurred after removal of screw in 2 cases of the rigid fixation group. At last follow-up, there was no significant difference in MCS, TFCS, TFO, AOFAS score and FADI score between 2 groups ( P >0.05). Suture-button fixation has similar effectiveness to screw fixation in ankle function and imaging findings, and flexible fixation has lower risk of reduction loss of distal tibiofibular syndesmosis than rigid fixation.

  8. Lower complication rate and faster return to sports in patients with acute syndesmotic rupture treated with a new knotless suture button device.

    PubMed

    Colcuc, Christian; Blank, Marc; Stein, Thomas; Raimann, Florian; Weber-Spickschen, Sanjay; Fischer, Sebastian; Hoffmann, Reinhard

    2017-12-09

    Suture button devices for tibiofibular syndesmosis injuries provide semirigid dynamic stabilization, but complications including knot irritation have been reported. No randomized trials of the new knotless suture button devices have been performed. We hypothesized that knotless suture button devices eliminate knot irritation and facilitate quicker return to sports. This study was performed to compare the clinical outcomes, complication rates, and time to return to sports between a new knotless suture button device and syndesmotic screw fixation. This study included 54 patients treated for ankle syndesmotic injury from 2012 to 2014 with a knotless suture button device or syndesmotic screw fixation. Clinical outcomes were measured using the American Orthopaedics Foot and Ankle Society score, Foot and Ankle Disability Index, Olerud and Molander score, and visual analog scale for pain and function. Secondary outcome measures were the complication rate and time required to return to sports. Patients underwent clinical and radiological evaluations preoperatively and three times during the 1-year postoperative follow-up. 54 of 62 eligible patients were analyzed, median age 37 (18-60) and underwent the 1-year follow-up. The screw fixation and knotless suture button groups comprised 26 and 28 patients, respectively. The complication rate was significantly lower (p = 0.03) and time to return to sports was significantly shorter in the knotless suture button than screw fixation group (average, 14 versus 19 weeks, respectively; p = 0.006). No significant differences were identified in clinical outcomes or visual analog scale scores for pain and function between the groups. Age, injury mechanism, and body mass index did not significantly affect the time required to return to sports activities. The type of fixation was the only independent variable that reached statistical significance (p = 0.006). Syndesmotic screw fixation and the new knotless suture button device both resulted in good clinical results. Lower complication rate and the earlier time to return to sports make the new knotless suture button device recommendable especially for highly active patients. Randomized controlled trial, Level I.

  9. Modified Labial Button Technique for Maintaining Occlusion After Caudal Mandibular Fracture/Temporomandibular Joint Luxation in the Cat.

    PubMed

    Goodman, Alice E; Carmichael, Daniel T

    2016-03-01

    Maxillofacial trauma in cats often results in mandibular symphyseal separation in addition to injuries of the caudal mandible and/or temporomandibular joint (TMJ). Caudal mandibular and TMJ injuries are difficult to access and stabilize using direct fixation techniques, thus indirect fixation is commonly employed. The immediate goals of fixation include stabilization for return to normal occlusion and function with the long-term objective of bony union. Indirect fixation techniques commonly used for stabilization of caudal mandibular and temporomandibular joint fracture/luxation include maxillomandibular fixation (MMF) with acrylic composite, interarcade wiring, tape muzzles, and the bignathic encircling and retaining device (BEARD) technique. This article introduces a modification of the previously described "labial reverse suture through buttons" technique used by Koestlin et al and the "labial locking with buttons" technique by Rocha et al. In cases with minimally displaced subcondylar and pericondylar fractures without joint involvement, the labial button technique can provide sufficient stabilization for healing. Advantages of the modified labial button technique include ease of application, noninvasive nature, and use of readily available materials. The construct can remain in place for a variable of amount of time, depending on its intended purpose. It serves as an alternative to the tape muzzle, which is rarely tolerated by cats. This technique can be easily used in conjunction with other maxillomandibular repairs, such as cerclage wire fixation of mandibular symphyseal separation. The purpose of this article is to demonstrate a modified labial button technique for maintaining occlusion of feline caudal mandibular fractures/TMJ luxations in a step-by-step fashion.

  10. A Retrospective Evaluation of Anatomical Reinsertion of the Distal Biceps Brachii Tendon Using an ACL TightRope® RT with a Titanium Cortical Button and Ultra High Molecular Weight Polyethylene Suture: A Preliminary Report.

    PubMed

    Witkowski, Jarosław; Kentel, Maciej; Królikowska, Aleksandra; Reichert, Paweł

    2016-01-01

    Various surgical techniques for treating distal biceps brachii tendon injury have been described, and to date there is no consensus regarding the preferred fixation method for the anatomic reinsertion of the ruptured tendon. The aim of the study was to clinically and functionally evaluate the upper limb after surgical anatomic reinsertion of the distal biceps brachii tendon using an ACL TightRope® RT with a titanium cortical button and ultra high molecular weight polyethylene (UHMWPE) suture, and to assess postoperative complications. The sample comprised 3 patients. Clinical examination (history, measurements of the active range of forearm motion, arm circumference, the maximum isometric forearm supination and flexion muscle torque), pain evaluation (on a visual analogue scale [VAS]) and functional assessment (the Mayo Elbow Performance Index [MEPI] and Quick Disabilities of the Arm, Shoulder and Hand [DASH]) were carried out. Complications were documented. The results of the range of motion measurements, arm circumferences and normalized isometric torque values of the muscle groups being studied were comparable in the involved and uninvolved limbs. The MEPI (x = 95.00 ± 10.42) and Quick DASH (x = 8.66 ± 18.04) scores revealed very good results. The VAS results were close to no pain (x = 3.33 ± 5.77 mm). No complications were noted. The preliminary comprehensive clinical and functional assessment of the upper limb justify the clinical use of the ACL TightRope® RT with a titanium cortical button and UHMWPE suture in surgical anatomic reinsertion of the distal biceps brachii tendon. The early results with a small sample were encouraging, but studies with a larger number of cases and longer follow-up are needed.

  11. Button fixation technique for Achilles tendon reinsertion: a biomechanical study.

    PubMed

    Awogni, David; Chauvette, Guillaume; Lemieux, Marie-Line; Balg, Frédéric; Langelier, Ève; Allard, Jean-Pascal

    2014-01-01

    Chronic insertional tendinopathy of the Achilles tendon is a frequent and disabling pathologic entity. Operative treatment is indicated for patients for whom nonoperative management has failed. The treatment can consist of the complete detachment of the tendon insertion and extensive debridement. We biomechanically tested a new operative technique that uses buttons for fixation of the Achilles tendon insertion on the posterior calcaneal tuberosity and compared it with 2 standard bone anchor techniques. A total of 40 fresh-frozen cadaver specimens were used to compare 3 fixation techniques for reinserting the Achilles tendon: single row anchors, double row anchors, and buttons. The ultimate loads and failure mechanisms were recorded. The button assembly (median load 764 N, range 713 to 888) yielded a median fixation strength equal to 202% (range 137% to 251%) of that obtained with the double row anchors (median load 412 N, range 301 to 571) and 255% (range 213% to 317%) of that obtained with the single row anchors (median load 338 N, range 241 to 433N). The most common failure mechanisms were suture breakage with the buttons (55%) and pull out of the implant with the double row (70%) and single row (85%) anchors. The results of the present biomechanical cadaver study have shown that Achilles tendon reinsertion fixation using the button technique provides superior pull out strength than the bone anchors tested. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Suture Button Fixation Treatment of Chronic Lisfranc Injury in Professional Dancers and High-Level Athletes.

    PubMed

    Charlton, Timothy; Boe, Chelsea; Thordarson, David B

    2015-12-01

    Chronic Lisfranc injury is a subtle and severe injury in high-level athletes, including dancers. This patient population is generally intolerant of intra-articular screw fixation and can develop significant post-traumatic arthritis with potentially career ending complications. Flexible fixation with suture-button devices provides potential restoration of physiologic motion at the joint, with appropriate support for healing that may facilitate return to en pointe activities for dancers. We hypothesized that the suture-button device would restore motion at the Lisfranc joint and allow for return to activities in this particular population without the limitations and complications of rigid fixation. We operated on seven dancers and high-level athletes with diagnosed Lisfranc injuries by installing a suture-button device. All patients had failed conservative management after late presentation. They were allowed to return to sport in 6 months, preoperative and postoperative American Orthopaedic Foot and Ankle Score (AOFAS) foot scores were obtained, and patients were followed for a minimum of 15 months. All seven returned to full activities in 6 months, with radiographic evidence of fixation and no complications to date. AOFAS foot scores improved from an average of 65 preoperatively to an average of 97 postoperatively at latest follow-up. It is concluded that flexible fixation with suture-button type device represents a viable alternative to screw fixation or fusion that may allow dancers and athletes to return to previous levels of activity after Lisfranc injury. This case series represents to our knowledge the first application of this device to a unique population that requires flexibility at the Lisfranc joint for performance.

  13. Surgical treatment of pectoralis major muscle rupture with adjustable cortical button.

    PubMed

    Pochini, Alberto de Castro; Rodrigues, Marcus de Souza Barbosa; Yamashita, Larissa; Belangero, Paulo Santoro; Andreoli, Carlos Vicente; Ejnisman, Benno

    2018-01-01

    To assess the tendon reconstruction technique for total rupture of the pectoralis major muscle using an adjustable cortical button. Prospective study of 27 male patients with a mean age of 29.9 (SD = 5.3 years) and follow-up of 2.3 years. The procedure consisted of autologous grafts taken from the semitendinosus and gracilis tendons and an adjustable cortical button. Patients were evaluated functionally by the Bak criteria. The surgical treatment of pectoralis major muscle tendon reconstruction was performed in the early stages (three weeks) in six patients (22.2%) and in 21 patients (77.8%), in the late stages. Patients operated with the adjustable cortical button technique obtained 96.3% excellent or good results, with only 3.7% having poor results (Bak criteria). Of the total, 85.2% were injured while performing bench press exercises and 14.8%, during the practice of Brazilian jiu-jitsu or wrestling. All weight-lifting athletes had history of anabolic steroid use. The early or delayed reconstruction of ruptured pectoralis major muscle tendons with considerable muscle retraction, using an adjustable cortical button and autologous knee flexor grafts, showed a high rate of good results.

  14. Double-button Fixation System for Management of Acute Acromioclavicular Joint Dislocation

    PubMed Central

    Torkaman, Ali; Bagherifard, Abolfazl; Mokhatri, Tahmineh; Haghighi, Mohammad Hossein Shabanpour; Monshizadeh, Siamak; Taraz, Hamid; Hasanvand, Amin

    2016-01-01

    Background: Surgical treatments for acromioclavicular (AC) joint dislocation present with some complications. The present study was designed to evaluate the double-button fixation system in the management of acute acromioclavicular joint dislocation. Methods: This cross sectional study, done between February 2011 to June 2014, consisted of 28 patients who underwent surgical management by the double-button fixation system for acute AC joint dislocation. Age, sex, injury mechanism, dominant hand, side with injury, length of follow up, time before surgery, shoulder and hand (DASH), constant and visual analogue scale (VAS) scores, and all complications of the cases during the follow up were recorded. Results: The mean age of patients was 33.23±6.7 years. Twenty four patients (85.71%) were male and four (14.28%) were female. The significant differences were observed between pre-operation VAS, constant shoulder scores and post-operation measurements. There were not any significant differences between right and left coracoclavicular, but two cases of heterotrophic ossifications were recorded. The mean follow-up time was 16.17±4.38 months. Conclusion: According to the results, the double-button fixation system for management of acute acromioclavicular joint dislocation has suitable results and minimal damage to the soft tissues surrounding the coracoclavicular ligaments. PMID:26894217

  15. Fixation of the Achilles tendon insertion using suture button technology.

    PubMed

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  16. Repair of Double Head Pectoralis Major Tendon Avulsion into its Native Footprint Using Bi-cortical EndoButtons and Tendon Sliding Technique.

    PubMed

    Prabhu, Jagadish; Faqi, Mohammed Khalid; Alkhalifa, Fahad; Tayara, Bader Kamal; Awad, Rashad Khamis

    2017-01-01

    Injuries to the pectoralis major muscle are relatively infrequent. The mechanism of injury is usually an eccentric shortening of the pectoralis major under heavy load, such as when performing a bench press exercise. We report a case that presented to us with a history of sudden pain in the left pectoral region while doing heavy bench press exercise. The patient sustained a type III D pectoralis muscle -tendon avulsion. Surgical repair was done through a bi-cortical tendon sliding technique using two cortical buttons. In this article we describe our modifications to the previously described surgical technique for the pectoralis major tendon repair using the EndoButton and tension - slide technique, aiming to overcome the possible complications.

  17. Results of minimal invasive coracoclavicular fixation by double button lift-up system in Neer type II distal clavicle fractures.

    PubMed

    Dedeoğlu, Süleyman Semih; İmren, Yunus; Çabuk, Haluk; Çakar, Murat; Arslan, Samet Murat; Esenyel, Cem Zeki

    2017-01-01

    We aimed to evaluate clinical and functional outcomes of indirect fracture reduction performed by coracoclavicular fixation with minimal invasive double button lift-up system in Neer type IIa unstable fractures of distal clavicle. 22 patients with Neer type 2 distal clavicle fracture were enrolled in that prospective study. All patients underwent indirect reduction and osteosynthesis performed by coracoclavicular fixation with minimal invasive double button lift-up system. Postoperative follow-up was carried out clinically and radiologically with plain X-rays and utilization of Constant and American Shoulder and Elbow Surgeons Standardized Shoulder Assessment (ASES) shoulder scores. Mean follow-up time was 15 months. A standard sling was applied for 2 weeks, postoperatively. Rehabilitation program was started on postoperative day 1. Mean age was 39 (range: 21-60), 18 of the patients were male. Right dominant extremity was affected in 14 patients. Mean duration of the surgical intervention was 40 min (range: 30-55 min). Mean union time was found to be 14 weeks (range: 7-21 weeks). Mean postoperative ASES and Constant scores were 79.9 (66.9-88.3) and 82.2 (71-100), respectively. The duration of return to normal daily activities were found to be 4.5 months. Any loss of reduction, AC joint arthrosis, and clavicular shortening were not detected in X-rays. This study has demonstrated that indirect osteosynthesis performed by coracoclavicular fixation with double button lift-up system in the treatment of unstable Neer type IIa fractures of the distal clavicle had successful clinical, radiological, and functional outcomes.

  18. A Novel Vesicoscopic Bladder Wall Suture Fixation Technique to Aid Endoscopic Vesicostomy Button Insertion

    PubMed Central

    Adam, Ahmed; Sookram, Jayveer

    2018-01-01

    Background To describe a novel bladder fixation technique for use during endoscopic vesicostomy button insertion. Methods After standard cystoscopic visualization of the bladder, a standard 18 G intravenous cannula was inserted into the bladder. A non-absorbable suture thread was placed through this intravenous cannula under cystoscopic vision. The proximal end of the suture was then removed using standard ureteroscopic grasping forceps (3 Fr) through another needle (15 G) inserted next to the initial puncture site (following a path at 30 degrees from the initial puncture tract) into the bladder. The suture ends were brought out of the bladder and tied at the skin level, 2 cm from the intended vesicostomy site. Sutures were removed on the second postoperative day. Results This fixation technique allows for adequate fixation of the bladder dome to the anterior abdominal wall. These sutures also have less potential for cutaneous scarring and pain. No complications were reported. Conclusion This simple fixation technique is easily performed using materials found in every urology suite. It also avoids the skills required with other previously reported fixation suture techniques, and can also be utilized for bladder fixation in cases of vesicoscopic laparoscopic or robotic assisted laparoscopic procedures. PMID:29692696

  19. Internal fixation of distal tibiofibular syndesmotic injuries: a systematic review with meta-analysis.

    PubMed

    Wang, Chen; Ma, Xin; Wang, Xu; Huang, Jiazhang; Zhang, Chao; Chen, Li

    2013-09-01

    No consensus had been reached about the optimal method for syndesmotic fixation. The present study analysed syndesmotic fixation based on the highest level of clinical evidence in order to obtain more reliable results. Medline, Embase and Cochrane database were searched through the OVID retrieval engine. Manual searching was undertaken afterward to identify additional studies. Only randomized controlled trials (RCT) and prospective comparative studies were selected for final inclusion. Study screening and data extraction were completed independently by two reviewers. All study characteristics were summarized into a table. The extracted data were used for data analysis. Twelve studies were finally included: six of them were RCTs, two were quasi-randomized studies and four were prospective comparative studies. Four comparisons with traditional metallic screw were identified in terms of bioabsorbable screws, tricortical fixation method, suture-button device as well as non-fixation choice in low syndesmotic injuries. Both absorbable screws and the tricortical fixation method showed almost no better results than traditional quadricortical metallic screw (p > 0.05). Additionally, existing studies could not illustrate their efficiency of reducing hardware removal rate. The suture button technique had significantly better functional score (p = 0.003), ankle motion (p = 0.02), time to full weightbearing (p < 0.0001) and much less complications (p = 0.0008) based on short and intermediate term follow-up data. Transfixation in low syndesmotic injuries showed poorer results than the non fixed group in all outcome measurements, but didn't reach a significant level (p > 0.05). The present evidence still couldn't find superior performance of the bioabsorbable screw and tricortical fixation method. Their true effects in decreasing second operation rate need further specific studies. Better results of the suture-button made it a promising technique, but it still needs long-term testing and cost-efficiency studies. The patients with low syndemotic injuries should be well assessed before fixation determination and the indication of screw placement in such conditions needs to be further defined.

  20. Arthroscopic Latarjet Techniques: Graft and Fixation Positioning Assessed With 2-Dimensional Computed Tomography Is Not Equivalent With Standard Open Technique.

    PubMed

    Neyton, Lionel; Barth, Johannes; Nourissat, Geoffroy; Métais, Pierre; Boileau, Pascal; Walch, Gilles; Lafosse, Laurent

    2018-05-19

    To analyze graft and fixation (screw and EndoButton) positioning after the arthroscopic Latarjet technique with 2-dimensional computed tomography (CT) and to compare it with the open technique. We performed a retrospective multicenter study (March 2013 to June 2014). The inclusion criteria included patients with recurrent anterior instability treated with the Latarjet procedure. The exclusion criterion was the absence of a postoperative CT scan. The positions of the hardware, the positions of the grafts in the axial and sagittal planes, and the dispersion of values (variability) were compared. The study included 208 patients (79 treated with open technique, 87 treated with arthroscopic Latarjet technique with screw fixation [arthro-screw], and 42 treated with arthroscopic Latarjet technique with EndoButton fixation [arthro-EndoButton]). The angulation of the screws was different in the open group versus the arthro-screw group (superior, 10.3° ± 0.7° vs 16.9° ± 1.0° [P < .001]; inferior, 10.3° ± 0.8° vs 15.7° ± 0.9° [P < .0001]). The angulation of the EndoButtons was 5.7° ± 0.5°; this was different from that of open inferior screws (P = .003). In the axial plane (level of equator), the arthroscopic techniques resulted in lateral positions (arthro-screw, 1.5 ± 0.3 mm lateral [P < .001]; arthro-EndoButton, 0 ± 0.3 mm lateral [P < .0001]) versus the open technique (0.9 ± 0.2 mm medial). At the level of 25% of the glenoid height, the arthroscopic techniques resulted in lateral positions (arthro-screw, 0.3 ± 0.3 mm lateral [P < .001]); (arthro-EndoButton, 0.7 ± 0.3 mm lateral [P < .0001]) versus the open technique (1.0 ± 0.2 mm medial). Higher variability was observed in the arthro-screw group. In the sagittal plane, the arthro-screw technique resulted in higher positions (55% ± 3% of graft below equator) and the arthro-EndoButton technique resulted in lower positions (82% ± 3%, P < .0001) versus the open technique (71% ± 2%). Variability was not different. This study shows that the position of the fixation devices and position of the bone graft with the arthroscopic techniques are statistically significantly different from those with the open technique with 2-dimensional CT assessment. In the sagittal plane, the arthro-screw technique provides the highest positions, and the arthro-EndoButton technique, the lowest. Overall, the mean position of the bone block with the open Latarjet technique in the axial plane is slightly medial to the joint line, as recommended. Conversely, with the arthroscopic techniques, the bone grafts are more lateral with a slight overhang. The main differences are observed in the dispersion of the values (more extreme positions) with the arthro-screw technique, given the acknowledged limitations. Despite the statistical significance, the clinical significance of these differences is yet unknown. Level III, retrospective comparative study. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  1. Lateral clavicle fracture with coracoclavicular ligament injury: a biomechanical study of 4 different repair techniques.

    PubMed

    Alaee, Farhang; Apostolakos, John; Singh, Hardeep; Holwein, Christian; Diermeier, Theresa; Cote, Mark P; Beitzel, Knut; Imhoff, Andreas B; Mazzocca, Augustus D; Voss, Andreas

    2017-07-01

    To investigate the biomechanical performance of four different methods used for coracoclavicular (CC) ligament reconstruction in a lateral clavicle fracture repair. Native displacement, translation, and rotation at the acromioclavicular joint of 24 fresh-frozen cadaveric shoulders were tested. A reproducible fracture in the lateral third of the clavicle was created by dissecting both CC ligaments. Each specimen was then repaired with plate fixation of the fracture and the following CC repair technique: (1) Cortical button. (2) Suture anchor and plate button. (3) Suture anchor no plate button, and (4) Suture around coracoid. All reconstructed specimens were then re-tested for displacement, translation, and load to failure, and compared to their native results. Groups 1 and 3 were investigated for rotational load. There was no difference in load to failure between the repaired groups (p: ns). Group 1 showed less superior and anterior translations (p < 0.05). Group 2 showed significantly less superior translation (p = 0.003), but no significance with anterior and posterior translations to the native joint. Group 3 showed less superior and posterior translations (p = 0.005 and p = 0.039). Anterior and posterior translations were increased in group 4 (p < 0.05). The biomechanical analyses did not show any significance in load to failure or displacement after cyclic loading among the study groups. All repairs were effective in preventing superior translation. Groups 1 and 2 demonstrated increased horizontal stability compared to the native state. All 4 methods are clinically viable options for CC ligament repair.

  2. Paying attention to saccadic intrusions.

    PubMed

    Gowen, E; Abadi, R V; Poliakoff, E

    2005-12-01

    Fixation to a target in primary gaze is invariably interrupted by physiological conjugate saccadic intrusions (SI). These small idiosyncratic eye movements (usually <1 degrees in amplitude) take the form of an initial horizontal fast eye movement away from the desired eye position, followed after a variable duration by a return saccade or drift. As the aetiology of SI is still unclear, it was the aim of this study to investigate whether SI are related to exogenous or endogenous attentional processes. This was achieved by varying (a) the "bottom-up" target viewing conditions (target presence, servo control of the target, target background, target size) and (b) the 'top-down' attentional state (instruction change--'look' or 'hold eyes steady' and passive fixation versus active--'respond to change' fixation) in 13 subjects (the number of participants in each task varied between 7 and 11). We also manipulated the orientation of pure exogenous attention through a cue-target task, during which subjects were required to respond to a target, preceded by a non-informative cue by either pressing a button or making a saccade towards the target. SI amplitude, duration, frequency and direction were measured. SI amplitude was found to be significantly higher when the target was absent and SI frequency significantly lower during open loop conditions. Target size and background influenced SI behaviour in an idiosyncratic manner, although there was a trend for subjects to exhibit lower SI frequencies and amplitudes when a patterned background was present and larger SI amplitudes with larger target sizes. SI frequency decreased during the "hold eyes steady" passive command as well as during active fixation but SI direction was not influenced by the exogenous cue-target task. These results suggest that SI are related to endogenous rather than exogenous attention mechanisms. Our experiments lead us to propose that SI represent shifts in endogenous attention that reflect a baseline attention state present during laboratory fixation tasks and may prove to be a useful tool to explore higher cortical control of fixation.

  3. Stimulus-dependent deliberation process leading to a specific motor action demonstrated via a multi-channel EEG analysis

    PubMed Central

    Henz, Sonja; Kutz, Dieter F.; Werner, Jana; Hürster, Walter; Kolb, Florian P.; Nida-Ruemelin, Julian

    2015-01-01

    The aim of the study was to determine whether a deliberative process, leading to a motor action, is detectable in high density EEG recordings. Subjects were required to press one of two buttons. In a simple motor task the subject knew which button to press, whilst in a color-word Stroop task subjects had to press the right button with the right index finger when meaning and color coincided, or the left button with the left index finger when meaning and color were disparate. EEG recordings obtained during the simple motor task showed a sequence of positive (P) and negative (N) cortical potentials (P1-N1-P2) which are assumed to be related to the processing of the movement. The sequence of cortical potentials was similar in EEG recordings of subjects having to deliberate over how to respond, but the above sequence (P1-N1-P2) was preceded by slowly increasing negativity (N0), with N0 being assumed to represent the end of the deliberation process. Our data suggest the existence of neurophysiological correlates of deliberative processes. PMID:26190987

  4. Secure fixation of femoral bone plug with a suspensory button in anatomical anterior cruciate ligament reconstruction with bone-patellar tendon-bone graft

    PubMed Central

    TAKETOMI, SHUJI; INUI, HIROSHI; NAKAMURA, KENSUKE; YAMAGAMI, RYOTA; TAHARA, KEITARO; SANADA, TAKAKI; MASUDA, HIRONARI; TANAKA, SAKAE; NAKAGAWA, TAKUMI

    2015-01-01

    Purpose the efficacy and safety of using a suspensory button for femoral fixation in anatomical anterior cruciate ligament (ACL) reconstruction with bone-patellar tendon-bone (BPTB) graft have not been established. The purpose of the current study was to evaluate bone plug integration onto the femoral socket and migration of the bone plug and the EndoButton (EB) (Smith & Nephew, Andover, MA, USA) after rectangular tunnel ACL reconstruction with BPTB autograft. Methods thirty-four patients who underwent anatomical rectangular ACL reconstruction with BPTB graft using EB for femoral fixation and in whom three-dimensional (3D) computed tomography (CT) was performed one week and one year after surgery were included in this study. Bone plug integration onto the femoral socket, bone plug migration, soft tissue interposition, EB migration and EB rotation were evaluated on 3D CT. The clinical outcome was also assessed and correlated with the imaging outcomes. Results the bone plug was integrated onto the femoral socket in all cases. The incidence of bone plug migration, soft tissue interposition, EB migration and EB rotation was 15, 15, 9 and 56%, respectively. No significant association was observed between the imaging outcomes. The postoperative mean Lysholm score was 97.1 ± 5.0 points. The postoperative side-to-side difference, evaluated using a KT-2000 arthrometer, averaged 0.5 ± 1.3 mm. There were no complications associated with EB use. Imaging outcomes did not affect the postoperative KT side-to-side difference. Conclusions the EB is considered a reliable device for femoral fixation in anatomical rectangular tunnel ACL reconstruction with BPTB autograft. Level of evidence Level IV, therapeutic case series. PMID:26889465

  5. Cortical Spatio-Temporal Dynamics Underlying Phonological Target Detection in Humans

    ERIC Educational Resources Information Center

    Chang, Edward F.; Edwards, Erik; Nagarajan, Srikantan S.; Fogelson, Noa; Dalal, Sarang S.; Canolty, Ryan T.; Kirsch, Heidi E.; Barbaro, Nicholas M.; Knight, Robert T.

    2011-01-01

    Selective processing of task-relevant stimuli is critical for goal-directed behavior. We used electrocorticography to assess the spatio-temporal dynamics of cortical activation during a simple phonological target detection task, in which subjects press a button when a prespecified target syllable sound is heard. Simultaneous surface potential…

  6. First metatarsal-phalangeal joint arthrodesis: a biomechanical assessment of stability.

    PubMed

    Politi, Joel; John, Hayes; Njus, Glen; Bennett, Gordon L; Kay, David B

    2003-04-01

    First metatarsal phalangeal joint (MTP) arthrodesis is a commonly performed procedure for the treatment of hallux rigidus, severe and recurrent bunion deformities, rheumatoid arthritis and other less common disorders of the joint. There are different techniques of fixation of the joint to promote arthrodesis including oblique lag screw fixation, lag screw and dorsal plate fixation, crossed Kirschner wires, dorsal plate fixation alone and various types of external fixation. Ideally the fixation method should be reproducible, lead to a high rate of fusion, and have a low incidence of complications. In the present study, we compared the strength of fixation of five commonly utilized techniques of first MTP joint arthrodesis. These were: 1. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical interfragmentary lag screw. 2. Surface excision with machined conical reaming and fixation with crossed 0.062 Kirschner wires. 3. Surface excision with machined conical reaming and fixation with a 3.5 mm cortical lag screw and a four hole dorsal miniplate secured with 3.5 mm cortical screws. 4. Surface excision with machined conical reaming and fixation with a four hole dorsal miniplate secured with 3.5 mm cortical screws and no lag screw. 5. Planar surface excision and fixation with a single oblique 3.5 mm interfragmentary cortical lag screw. Testing was done on an Instron materials testing device loading the first MTP joint in dorsiflexion. Liquid metal strain gauges were placed over the joint and micromotion was detected with varying loads and cycles. The most stable technique was the combination of machined conical reaming and an oblique interfragmentary lag screw and dorsal plate. This was greater than two times stronger than an oblique lag screw alone. Dorsal plate alone and Kirschner wire fixation were the weakest techniques. First MTP fusion is a commonly performed procedure for the treatment of a variety of disorders of the first MTP joint. The most stable technique for obtaining fusion in this study was the combination of an oblique lag screw and a dorsal plate. This should lead to higher rates of arthrodesis.

  7. Fixation of unstable type II clavicle fractures with distal clavicle plate and suture button.

    PubMed

    Johnston, Peter S; Sears, Benjamin W; Lazarus, Mark R; Frieman, Barbara G

    2014-11-01

    This article reports on a technique to treat unstable type II distal clavicle fractures using fracture-specific plates and coracoclavicular augmentation with a suture button. Six patients with clinically unstable type II distal clavicle fractures underwent treatment using the above technique. All fractures demonstrated radiographic union at 9.6 (8.4-11.6) weeks with a mean follow-up of 15.6 (12.4-22.3) months. American Shoulder and Elbow Surgeons, Penn Shoulder Score, and Single Assessment Numeric Evaluation scores were 97.97 (98.33-100), 96.4 (91-99), and 95 (90-100), respectively. One patient required implant removal. Fracture-specific plating with suture-button augmentation for type II distal clavicle fractures provides reliable rates of union without absolute requirement for implant removal.

  8. Minimally invasive reconstruction of acute type IV and Type V acromioclavicular separations.

    PubMed

    Katsenis, Dimitris L; Stamoulis, Dimitris; Begkas, Dimitris; Tsamados, Stamatis

    2015-04-01

    The goal of this study was to evaluate the midterm radiologic, clinical, and functional results of the early reconstruction of the severe acromioclavicular joint dislocation using the flipptack fixation button technique. Between December 2006 and December 2009, one hundred thirty-five consecutive patients with acromioclavicular joint separations were admitted to the authors' institution. Fifty patients were included in the study. According to Rockwood classification, 29 (58%) dislocations were type IV and 21 (42%) were type V. Surgery was performed at an average of 4.2 days (range, 0-12 days) after dislocation. All dislocations were treated with the flipptack fixation button technique. All patients were evaluated at a final postoperative follow-up of 42 months (range, 36-49 months). The clinical outcome was assessed using the Constant score. The functional limitation was assessed using the bother index of the short Musculoskeletal Function Assessment. Radiographs taken immediately postoperatively and at the final follow-up assessed acromioclavicular joint reduction, coracoclavicular distance, and joint arthrosis. At the final follow-up, mean Constant score was 93.04 (range, 84-100). The average (±SD) short Musculoskeletal Function Assessment bother index was 20.88±8.95 (range, 2.0-49). No statistically significant difference was found between the acromioclavicular joint dislocation type and the clinical result (P=.227; chi-square, 6.910, Kruskal Wallis test). The regression of the coracoclavicular distance at final follow-up was not statistically significant (P=.276; chi-square, 6.319, Kruskal Wallis test). The flipptack fixation button technique is an effective alternative for the treatment of severe acromioclavicular joint dislocation. Because all objectives of the treatment were obtained, the results do not deteriorate over time. Copyright 2015, SLACK Incorporated.

  9. Objective guidelines for removing an external fixator after tibial lengthening using pixel value ratio: a pilot study.

    PubMed

    Zhao, Li; Fan, Qing; Venkatesh, K P; Park, Man S; Song, Hae Ryong

    2009-12-01

    During limb lengthening over an intramedullary nail, decisions regarding external fixator removal and weightbearing depend on the amount of callus seen at the lengthening area on radiographs. However, this method is subjective and objective evaluation of the amount of callus likely would minimize nail or interlocking screw breakage and refracture after fixator removal. We asked how many cortices with full corticalization of the newly formed bone at the lengthening area are needed to allow fixator removal and full weightbearing and how to radiographically determine the stage of corticalization. We retrospectively reviewed 17 patients (34 lengthenings) who underwent bilateral tibial lengthenings over an intramedullary nail. The average gain in length was 7.2 +/- 3.4 cm. We determined the pixel value ratio (ratio of pixel value of regenerate versus the mean pixel value of adjacent bone) of the lengthened area on radiographs. There were no nail or screw breakage and refracture. Partial weightbearing with crutches was permitted when the pixel value ratio was 1 in two cortices and full weightbearing without crutches was permitted when the pixel value ratio was 1 in three cortices. The pixel value ratio on radiographs can be an objective parameter for callus measurement and may provide guidelines for the timing of external fixator removal. We cannot determine from our limited data the minimum pixel value in how many cortices would suggest safe removal, but we can say our criteria were not associated with subsequent refracture.

  10. Discriminating between intentional and unintentional gaze fixation using multimodal-based fuzzy logic algorithm for gaze tracking system with NIR camera sensor

    NASA Astrophysics Data System (ADS)

    Naqvi, Rizwan Ali; Park, Kang Ryoung

    2016-06-01

    Gaze tracking systems are widely used in human-computer interfaces, interfaces for the disabled, game interfaces, and for controlling home appliances. Most studies on gaze detection have focused on enhancing its accuracy, whereas few have considered the discrimination of intentional gaze fixation (looking at a target to activate or select it) from unintentional fixation while using gaze detection systems. Previous research methods based on the use of a keyboard or mouse button, eye blinking, and the dwell time of gaze position have various limitations. Therefore, we propose a method for discriminating between intentional and unintentional gaze fixation using a multimodal fuzzy logic algorithm applied to a gaze tracking system with a near-infrared camera sensor. Experimental results show that the proposed method outperforms the conventional method for determining gaze fixation.

  11. [The biomechanics of screws, cerclage wire and cerclage cable].

    PubMed

    Schröder, C; Woiczinski, M; Utzschneider, S; Kraxenberger, M; Weber, P; Jansson, V

    2013-05-01

    In contrast to fracture fixation, when performing an osteotomy the surgeon is able to plan preoperatively. The resulting fixation and compression of the bone fragments are the most important points. A stable osteosynthesis should prevent dislocation of bone fragments and improve bone healing. Beside plates, cerclages can be used for tension band or diaphysis bone fixation. Moreover, cortical or cancellous screws can be used for osteotomy fixation. This work describes biomechanical principles for fixation after an osteotomy with cerclages and cortical or cancellous screws. It also summarizes the materials and geometries used, as well as their influence on the stability of the osteosynthesis.

  12. Delayed mirror visual feedback presented using a novel mirror therapy system enhances cortical activation in healthy adults.

    PubMed

    Lee, Hsin-Min; Li, Ping-Chia; Fan, Shih-Chen

    2015-07-11

    Mirror visual feedback (MVF) generated in mirror therapy (MT) with a physical mirror promotes the recovery of hemiparetic limbs in patients with stroke, but is limited in that it cannot provide an asymmetric mode for bimanual coordination training. Here, we developed a novel MT system that can manipulate the MVF to resolve this issue. The aims of this pilot study were to examine the feasibility of delayed MVF on MT and to establish its effects on cortical activation in order to understand how it can be used for clinical applications in the future. Three conditions (no MVF, MVF, and 2-s delayed MVF) presented via our digital MT system were evaluated for their time-course effects on cortical activity by event-related desynchronization (ERD) of mu rhythm electroencephalography (EEG) during button presses in 18 healthy adults. Phasic ERD areas, defined as the areas of the relative ERD curve that were below the reference level and within -2-0 s (P0), 0-2 s (P1), and 2-4 s (P2) of the button press, were used. The overall (P0 to P2) and phasic ERD areas were higher when MVF was provided compared to when MVF was not provided for all EEG channels (C3, Cz, and C4). Phasic ERD areas in the P2 phase only increased during the delayed-MVF condition. Significant enhancement of cortical activation in the mirror neuron system and an increase in attention to the unseen limb may play major roles in the response to MVF during MT. In comparison to the no MVF condition, the higher phasic ERD areas that were observed during the P1 phase in the delayed-MVF condition indicate that the image of the still hand may have enhanced the cortical activation that occurred in response to the button press. This study is the first to achieve delayed MVF for upper-limb MT. Our approach confirms previous findings regarding the effects of MVF on cortical activation and contributes additional evidence supporting the use of this method in the future for upper-limb motor training in patients with stroke.

  13. Comparison of screw fixation with elastic fixation methods in the treatment of syndesmosis injuries in ankle fractures.

    PubMed

    Seyhan, Mustafa; Donmez, Ferdi; Mahirogullari, Mahir; Cakmak, Selami; Mutlu, Serhat; Guler, Olcay

    2015-07-01

    17 patients with ankle syndesmosic injury were treated with a 4.5mm single cortical screw fixation (passage of screw 4 cortices) and 15 patients were treated with single-level elastic fixation material. All patients were evaluated according to the AOFAS ankle and posterior foot scale at the third, sixth and twelfth months after the fixation. The ankle range of movement was recorded together with the healthy side. The Student's t test was used for statistical comparisons. No statistical significant difference was observed between the AOFAS scores (p>0.05). The range of dorsiflexion and plantar flexion motion of the elastic fixation group at the 6th and 12th months were significantly better compared to the screw fixation group (p<0.01). Elastic fixation is as functional as screw fixation in the treatment of ankle syndesmosis injuries. The unnecessary need of a second surgical intervention for removal of the fixation material is another advantageous aspect of this method of fixation. Copyright © 2015. Published by Elsevier Ltd.

  14. Better Axial Stiffness of a Bicortical Screw Construct Compared to a Cable Construct for Comminuted Vancouver B1 Proximal Femoral Fractures.

    PubMed

    Griffiths, Jamie T; Taheri, Arash; Day, Robert E; Yates, Piers J

    2015-12-01

    The aim of this study was to biomechanically evaluate the Locking attachment plate (LAP) construct in comparison to a Cable plate construct, for the fixation of periprosthetic femoral fractures after cemented total hip arthroplasty. Each construct incorporated a locking compression plate with bi-cortical locking screws for distal fixation. In the Cable construct, 2 cables and 2 uni-cortical locking screws were used for proximal fixation. In the LAP construct, the cables were replaced by a LAP with 4 bi-cortical locking screws. The LAP construct was significantly stiffer than the cable construct under axial load with a bone gap (P=0.01). The LAP construct offers better axial stiffness compared to the cable construct in the fixation of comminuted Vancouver B1 proximal femoral fractures. Crown Copyright © 2015. Published by Elsevier Inc. All rights reserved.

  15. Multiple Transient Signals in Human Visual Cortex Associated with an Elementary Decision

    PubMed Central

    Nolte, Guido

    2017-01-01

    The cerebral cortex continuously undergoes changes in its state, which are manifested in transient modulations of the cortical power spectrum. Cortical state changes also occur at full wakefulness and during rapid cognitive acts, such as perceptual decisions. Previous studies found a global modulation of beta-band (12–30 Hz) activity in human and monkey visual cortex during an elementary visual decision: reporting the appearance or disappearance of salient visual targets surrounded by a distractor. The previous studies disentangled neither the motor action associated with behavioral report nor other secondary processes, such as arousal, from perceptual decision processing per se. Here, we used magnetoencephalography in humans to pinpoint the factors underlying the beta-band modulation. We found that disappearances of a salient target were associated with beta-band suppression, and target reappearances with beta-band enhancement. This was true for both overt behavioral reports (immediate button presses) and silent counting of the perceptual events. This finding indicates that the beta-band modulation was unrelated to the execution of the motor act associated with a behavioral report of the perceptual decision. Further, changes in pupil-linked arousal, fixational eye movements, or gamma-band responses were not necessary for the beta-band modulation. Together, our results suggest that the beta-band modulation was a top-down signal associated with the process of converting graded perceptual signals into a categorical format underlying flexible behavior. This signal may have been fed back from brain regions involved in decision processing to visual cortex, thus enforcing a “decision-consistent” cortical state. SIGNIFICANCE STATEMENT Elementary visual decisions are associated with a rapid state change in visual cortex, indexed by a modulation of neural activity in the beta-frequency range. Such decisions are also followed by other events that might affect the state of visual cortex, including the motor command associated with the report of the decision, an increase in pupil-linked arousal, fixational eye movements, and fluctuations in bottom-up sensory processing. Here, we ruled out the necessity of these events for the beta-band modulation of visual cortex. We propose that the modulation reflects a decision-related state change, which is induced by the conversion of graded perceptual signals into a categorical format underlying behavior. The resulting decision signal may be fed back to visual cortex. PMID:28495972

  16. Motor Cortex-Evoked Activity in Reciprocal Muscles Is Modulated by Reward Probability

    PubMed Central

    Suzuki, Makoto; Kirimoto, Hikari; Sugawara, Kazuhiro; Oyama, Mineo; Yamada, Sumio; Yamamoto, Jun-ichi; Matsunaga, Atsuhiko; Fukuda, Michinari; Onishi, Hideaki

    2014-01-01

    Horizontal intracortical projections for agonist and antagonist muscles exist in the primary motor cortex (M1), and reward may induce a reinforcement of transmission efficiency of intracortical circuits. We investigated reward-induced change in M1 excitability for agonist and antagonist muscles. Participants were 8 healthy volunteers. Probabilistic reward tasks comprised 3 conditions of 30 trials each: 30 trials contained 10% reward, 30 trials contained 50% reward, and 30 trials contained 90% reward. Each trial began with a cue (red fixation cross), followed by blue circle for 1 s. The subjects were instructed to perform wrist flexion and press a button with the dorsal aspect of middle finger phalanx as quickly as possible in response to disappearance of the blue circle without looking at their hand or the button. Two seconds after the button press, reward/non-reward stimulus was randomly presented for 2-s duration. The reward stimulus was a picture of Japanese 10-yen coin, and each subject received monetary reward at the end of experiment. Subjects were not informed of the reward probabilities. We delivered transcranial magnetic stimulation of the left M1 at the midpoint between center of gravities of agonist flexor carpi radialis (FCR) and antagonist extensor carpi radialis (ECR) muscles at 2 s after the red fixation cross and 1 s after the reward/non-reward stimuli. Relative motor evoked potential (MEP) amplitudes at 2 s after the red fixation cross were significantly higher for 10% reward probability than for 90% reward probability, whereas relative MEP amplitudes at 1 s after reward/non-reward stimuli were significantly higher for 90% reward probability than for 10% and 50% reward probabilities. These results implied that reward could affect the horizontal intracortical projections in M1 for agonist and antagonist muscles, and M1 excitability including the reward-related circuit before and after reward stimulus could be differently altered by reward probability. PMID:24603644

  17. Abnormalities of fixation, saccade and pursuit in posterior cortical atrophy.

    PubMed

    Shakespeare, Timothy J; Kaski, Diego; Yong, Keir X X; Paterson, Ross W; Slattery, Catherine F; Ryan, Natalie S; Schott, Jonathan M; Crutch, Sebastian J

    2015-07-01

    The clinico-neuroradiological syndrome posterior cortical atrophy is the cardinal 'visual dementia' and most common atypical Alzheimer's disease phenotype, offering insights into mechanisms underlying clinical heterogeneity, pathological propagation and basic visual phenomena (e.g. visual crowding). Given the extensive attention paid to patients' (higher order) perceptual function, it is surprising that there have been no systematic analyses of basic oculomotor function in this population. Here 20 patients with posterior cortical atrophy, 17 patients with typical Alzheimer's disease and 22 healthy controls completed tests of fixation, saccade (including fixation/target gap and overlap conditions) and smooth pursuit eye movements using an infrared pupil-tracking system. Participants underwent detailed neuropsychological and neurological examinations, with a proportion also undertaking brain imaging and analysis of molecular pathology. In contrast to informal clinical evaluations of oculomotor dysfunction frequency (previous studies: 38%, current clinical examination: 33%), detailed eyetracking investigations revealed eye movement abnormalities in 80% of patients with posterior cortical atrophy (compared to 17% typical Alzheimer's disease, 5% controls). The greatest differences between posterior cortical atrophy and typical Alzheimer's disease were seen in saccadic performance. Patients with posterior cortical atrophy made significantly shorter saccades especially for distant targets. They also exhibited a significant exacerbation of the normal gap/overlap effect, consistent with 'sticky fixation'. Time to reach saccadic targets was significantly associated with parietal and occipital cortical thickness measures. On fixation stability tasks, patients with typical Alzheimer's disease showed more square wave jerks whose frequency was associated with lower cerebellar grey matter volume, while patients with posterior cortical atrophy showed large saccadic intrusions whose frequency correlated significantly with generalized reductions in cortical thickness. Patients with both posterior cortical atrophy and typical Alzheimer's disease showed lower gain in smooth pursuit compared to controls. The current study establishes that eye movement abnormalities are near-ubiquitous in posterior cortical atrophy, and highlights multiple aspects of saccadic performance which distinguish posterior cortical atrophy from typical Alzheimer's disease. We suggest the posterior cortical atrophy oculomotor profile (e.g. exacerbation of the saccadic gap/overlap effect, preserved saccadic velocity) reflects weak input from degraded occipito-parietal spatial representations of stimulus location into a superior collicular spatial map for eye movement regulation. This may indicate greater impairment of identification of oculomotor targets rather than generation of oculomotor movements. The results highlight the critical role of spatial attention and object identification but also precise stimulus localization in explaining the complex real world perception deficits observed in posterior cortical atrophy and many other patients with dementia-related visual impairment. © The Author (2015). Published by Oxford University Press on behalf of the Guarantors of Brain.

  18. An in vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: an axial positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion versus three parallel transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Riggs, Laura M; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S

    2010-01-01

    To compare in vitro monotonic biomechanical properties of an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion (DCP-TLS) with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion (3-TLS) for the equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=15 pairs). For each forelimb pair, 1 PIP joint was stabilized with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion and 1 with 3 parallel transarticular 5.5 mm cortical screws inserted in lag fashion. Five matching pairs of constructs were tested in single cycle to failure under axial compression, 5 construct pairs were tested for cyclic fatigue under axial compression, and 5 construct pairs were tested in single cycle to failure under torsional loading. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load under axial compression and torsion, single cycle to failure, of the DCP-TLS fixation were significantly greater than those of the 3-TLS fixation. Mean cycles to failure in axial compression of the DCP-TLS fixation was significantly greater than that of the 3-TLS fixation. The DCP-TLS was superior to the 3-TLS in resisting the static overload forces and in resisting cyclic fatigue. The results of this in vitro study may provide information to aid in the selection of a treatment modality for arthrodesis of the equine PIP joint.

  19. Free Bone Plug Quadriceps Tendon Harvest and Suspensory Button Attachment for Anterior Cruciate Ligament Reconstruction.

    PubMed

    Todor, Adrian; Caterev, Sergiu; Nistor, Dan Viorel; Khallouki, Youssef

    2016-06-01

    The most commonly used autografts for anterior cruciate ligament reconstruction are the bone-patellar tendon-bone and hamstring tendons. Each has its advantages and limitations. The bone-patellar tendon-bone autograft can lead to more donor-site morbidity, and the hamstring autograft can be unpredictable in size. The quadriceps tendon, with or without a bone block, has been described as an alternative graft source and has been used especially in revision cases, but in recent years, it has attracted attention even for primary cases. We report a technique for harvesting a free bone quadriceps tendon graft and attaching an extracortical button for femoral fixation for anterior cruciate ligament reconstruction.

  20. Electrophysiological Correlates of the Threshold to Detection of Passive Motion: An Investigation in Professional Volleyball Athletes with and without Atrophy of the Infraspinatus Muscle

    PubMed Central

    Salles, José Inácio; Cossich, Victor Rodrigues Amaral; Amaral, Marcus Vinicius; Monteiro, Martim T.; Cagy, Maurício; Motta, Geraldo; Velasques, Bruna; Piedade, Roberto; Ribeiro, Pedro

    2013-01-01

    The goal of the present study is to compare the electrophysiological correlates of the threshold to detection of passive motion (TTDPM) among three groups: healthy individuals (control group), professional volleyball athletes with atrophy of the infraspinatus muscle on the dominant side, and athletes with no shoulder pathologies. More specifically, the study aims at assessing the effects of infraspinatus muscle atrophy on the cortical representation of the TTDPM. A proprioception testing device (PTD) was used to measure the TTDPM. The device passively moved the shoulder and participants were instructed to respond as soon as movement was detected (TTDPM) by pressing a button switch. Response latency was established as the delay between the stimulus (movement) and the response (button press). Electroencephalographic (EEG) and electromyographic (EMG) activities were recorded simultaneously. An analysis of variance (ANOVA) and subsequent post hoc tests indicated a significant difference in latency between the group of athletes without the atrophy when compared both to the group of athletes with the atrophy and to the control group. Furthermore, distinct patterns of cortical activity were observed in the three experimental groups. The results suggest that systematically trained motor abilities, as well as the atrophy of the infraspinatus muscle, change the cortical representation of the different stages of proprioceptive information processing and, ultimately, the cortical representation of the TTDPM. PMID:23484136

  1. Computational Evaluation of the Effects of Bone Ingrowth on Bone Resorptive Remodeling after a Cementless Total Hip Arthroplasty

    NASA Astrophysics Data System (ADS)

    Jung, Duk-Young; Kang, Yu-Bong; Tsutsumi, Sadami; Nakai, Ryusuke; Ikeuchi, Ken; Sekel, Ron

    In this study, we simulated a wide cortex separation from a cementless hip prosthesis using the bone resorption remodeling method that is based on the generation of high compressive stress around the distal cortical bone. Thereafter, we estimated the effect on late migration quantities of the hip prosthesis produced by the interface state arising from bone ingrowth. This was accomplished using cortical bone remodeling over a long period of time. Two-dimensional natural hip and implanted hip FEM models were constructed with each of the following interface statements between the bone and prosthesis: (1) non-fixation, (2) proximal 1/3, (3) proximal 2/3 and (4) full-fixation. The fixation interfaces in the fully and partially porous coated regions were rigidly fixed by bony ingrowth. The non-fixation model was constructed as a critical situation, with the fibrous or bony tissue not integrated at all into the implant surface. The daily load history was generated using the three loading cases of a one-legged stance as well as abduction and adduction motions. With the natural hip and one-legged stance, the peak compressive principal stresses were found to be under the criteria value for causing bone resorption, while no implant movement occurred. The migration magnitude of the stem of the proximal 1/3 fixation model with adduction motion was much higher, reaching 6%, 11%and 21%greater than those of the non-fixation, proximal 2/3 fixation and all-fixation models, respectively. The full-fixation model showed the lowest compressive principal stress and implant movement. Thus, we concluded that the late loosening and subsequent movement of the stem in the long term could be estimated with the cortical bone remodeling method based on a high compressive stress at the bone-implant interface. The change caused at the bone-prosthesis interface by bony or fibrous tissue ingrowth constituted the major factor in determining the extent of cortical bone resorption occurring with clinical loosening and subsequent implant movement.

  2. Effects of three different preservation methods on the mechanical properties of human and bovine cortical bone.

    PubMed

    Unger, Stefan; Stefan, Unger; Blauth, Michael; Michael, Blauth; Schmoelz, Werner; Werner, Schmoelz

    2010-12-01

    In the development of new strategies for fracture fixation, new methods have to be tested biomechanically under in vitro conditions before clinical trials can be performed. The gold standard for laboratory evaluations is fresh-frozen specimen. As the availability of fresh-frozen specimens is limited and since their use bears infectious risks, specimens treated with various chemical embalming fluids are also used. These preservation methods may alter the mechanical properties of the specimens used. Therefore, the aims of the present study were to determine the effects of three different preservation methods (formalin fixation (FO), Thiel-fixation (TH), and alcohol-glycerine fixation (AG)) on the elastic and postyield mechanical properties of cortical bone and to compare these properties to those of fresh-frozen (FF) specimens. Cylindrical cortical specimens (diameter 3mm, length 60 mm) were obtained from human femurs (n=48) and bovine tibiae (n=40). Before specimen immersion in different fixation fluids, bone mineral density (BMD) as well as the initial Young's modulus was determined. The Young's modulus was determined in a nondestructive bending test, and measurements were repeated after 6 months of immersion in fixative solution. Subsequent to the nondestructive test, a destructive 3-point bending test was conducted to assess the postyield and fracture properties. The BMD as well as the initial Young's modulus showed no significant differences between the four test groups. After 6 months in fixative solution, the Young's modulus was significantly lowered in human Thiel specimens and only showed minor changes in formalin- and alcohol-glycerine-treated specimens. The plastic energy absorption of human and bovine specimens was altered significantly. Formalin as well as alcohol-glycerine fixation yielded a significant decrease in plastic energy absorption, whereas Thiel fixation significantly increased the plastic energy absorption. Because of the significantly altered plastic mechanical properties of cortical bone, the use fresh-frozen bone specimens is recommended in biomechanical studies investigating failure loads of orthopaedic implants. The use of embalmed specimens should be restricted to pilot tests. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. Effect of Complete Syndesmotic Disruption and Deltoid Injuries and Different Reduction Methods on Ankle Joint Contact Mechanics.

    PubMed

    LaMothe, Jeremy; Baxter, Josh R; Gilbert, Susannah; Murphy, Conor I; Karnovsky, Sydney C; Drakos, Mark C

    2017-06-01

    Syndesmotic injuries can be associated with poor patient outcomes and posttraumatic ankle arthritis, particularly in the case of malreduction. However, ankle joint contact mechanics following a syndesmotic injury and reduction remains poorly understood. The purpose of this study was to characterize the effects of a syndesmotic injury and reduction techniques on ankle joint contact mechanics in a biomechanical model. Ten cadaveric whole lower leg specimens with undisturbed proximal tibiofibular joints were prepared and tested in this study. Contact area, contact force, and peak contact pressure were measured in the ankle joint during simulated standing in the intact, injured, and 3 reduction conditions: screw fixation with a clamp, screw fixation without a clamp (thumb technique), and a suture-button construct. Differences in these ankle contact parameters were detected between conditions using repeated-measures analysis of variance. Syndesmotic disruption decreased tibial plafond contact area and force. Syndesmotic reduction did not restore ankle loading mechanics to values measured in the intact condition. Reduction with the thumb technique was able to restore significantly more joint contact area and force than the reduction clamp or suture-button construct. Syndesmotic disruption decreased joint contact area and force. Although the thumb technique performed significantly better than the reduction clamp and suture-button construct, syndesmotic reduction did not restore contact mechanics to intact levels. Decreased contact area and force with disruption imply that other structures are likely receiving more loads (eg, medial and lateral gutters), which may have clinical implications such as the development of posttraumatic arthritis.

  4. Abnormalities of fixation, saccade and pursuit in posterior cortical atrophy

    PubMed Central

    Kaski, Diego; Yong, Keir X. X.; Paterson, Ross W.; Slattery, Catherine F.; Ryan, Natalie S.; Schott, Jonathan M.; Crutch, Sebastian J.

    2015-01-01

    The clinico-neuroradiological syndrome posterior cortical atrophy is the cardinal ‘visual dementia’ and most common atypical Alzheimer’s disease phenotype, offering insights into mechanisms underlying clinical heterogeneity, pathological propagation and basic visual phenomena (e.g. visual crowding). Given the extensive attention paid to patients’ (higher order) perceptual function, it is surprising that there have been no systematic analyses of basic oculomotor function in this population. Here 20 patients with posterior cortical atrophy, 17 patients with typical Alzheimer’s disease and 22 healthy controls completed tests of fixation, saccade (including fixation/target gap and overlap conditions) and smooth pursuit eye movements using an infrared pupil-tracking system. Participants underwent detailed neuropsychological and neurological examinations, with a proportion also undertaking brain imaging and analysis of molecular pathology. In contrast to informal clinical evaluations of oculomotor dysfunction frequency (previous studies: 38%, current clinical examination: 33%), detailed eyetracking investigations revealed eye movement abnormalities in 80% of patients with posterior cortical atrophy (compared to 17% typical Alzheimer’s disease, 5% controls). The greatest differences between posterior cortical atrophy and typical Alzheimer’s disease were seen in saccadic performance. Patients with posterior cortical atrophy made significantly shorter saccades especially for distant targets. They also exhibited a significant exacerbation of the normal gap/overlap effect, consistent with ‘sticky fixation’. Time to reach saccadic targets was significantly associated with parietal and occipital cortical thickness measures. On fixation stability tasks, patients with typical Alzheimer’s disease showed more square wave jerks whose frequency was associated with lower cerebellar grey matter volume, while patients with posterior cortical atrophy showed large saccadic intrusions whose frequency correlated significantly with generalized reductions in cortical thickness. Patients with both posterior cortical atrophy and typical Alzheimer’s disease showed lower gain in smooth pursuit compared to controls. The current study establishes that eye movement abnormalities are near-ubiquitous in posterior cortical atrophy, and highlights multiple aspects of saccadic performance which distinguish posterior cortical atrophy from typical Alzheimer’s disease. We suggest the posterior cortical atrophy oculomotor profile (e.g. exacerbation of the saccadic gap/overlap effect, preserved saccadic velocity) reflects weak input from degraded occipito-parietal spatial representations of stimulus location into a superior collicular spatial map for eye movement regulation. This may indicate greater impairment of identification of oculomotor targets rather than generation of oculomotor movements. The results highlight the critical role of spatial attention and object identification but also precise stimulus localization in explaining the complex real world perception deficits observed in posterior cortical atrophy and many other patients with dementia-related visual impairment. PMID:25895507

  5. Stress-Shielding Effect of Nitinol Swan-Like Memory Compressive Connector on Fracture Healing of Upper Limb

    NASA Astrophysics Data System (ADS)

    Fu, Q. G.; Liu, X. W.; Xu, S. G.; Li, M.; Zhang, C. C.

    2009-08-01

    In this article, the stress-shielding effect of a Nitinol swan-like memory compressive connector (SMC) is evaluated. Patients with fracture healing of an upper limb after SMC internal fixation or stainless steel plate fixation were randomly selected and observed comparatively. With the informed consent of the SMC group, minimal cortical bone under the swan-body and swan-neck was harvested; and in the steel plate fixation group, minimal cortical bone under the steel plate and opposite side to the steel plate was also harvested for observation. Main outcome measurements were taken such as osteocyte morphology, Harversian canal histological observation under light microscope; radiographic observation of fracture healing, and computed tomography quantitative scanning of cortical bone. As a conclusion, SMC has a lesser stress-shielding effect to fixed bone than steel plate. Finally, the mechanism of the lesser stress-shielding effect of SMC is discussed.

  6. Microtubule heterogeneity of Ornithogalum umbellatum ovary epidermal cells: non-stable cortical microtubules and stable lipotubuloid microtubules.

    PubMed

    Kwiatkowska, Maria; Stępiński, Dariusz; Polit, Justyna T; Popłońska, Katarzyna; Wojtczak, Agnieszka

    2011-01-01

    Lipotubuloids, structures containing lipid bodies and microtubules, are described in ovary epidermal cells of Ornithogalum umbellatum. Microtubules of lipotubuloids can be fixed in electron microscope fixative containing only buffered OsO(4) or in glutaraldehyde with OsO(4) post-fixation, or in a mixture of OsO(4) and glutaraldehyde. None of these substances fixes cortical microtubules of ovary epidermis of this plant which is characterized by dynamic longitudinal growth. However, cortical microtubules can be fixed with cold methanol according immunocytological methods with the use of β-tubulin antibodies and fluorescein. The existence of cortical microtubules has also been evidenced by EM observations solely after the use of taxol, microtubule stabilizer, and fixation in a glutaraldehyde/OsO(4) mixture. These microtubules mostly lie transversely, sometimes obliquely, and rarely parallel to the cell axis. Staining, using Ruthenium Red and silver hexamine, has revealed that lipotubuloid microtubules surface is covered with polysaccharides. The presumption has been made that the presence of a polysaccharide layer enhances the stability of lipotubuloid microtubules.

  7. Screw fixation of the syndesmosis: a cadaver model comparing stainless steel and titanium screws and three and four cortical fixation.

    PubMed

    Beumer, Annechien; Campo, Martin M; Niesing, Ruud; Day, Judd; Kleinrensink, Gert-Jan; Swierstra, Bart A

    2005-01-01

    We assessed syndesmotic set screw strength and fixation capacity during cyclical testing in a cadaver model simulating protected weight bearing. Sixteen fresh frozen legs with artificial syndesmotic injuries and a syndesmotic set screw made of stainless steel or titanium, inserted through three or four cortices, were axially loaded with 800 N for 225,000 cycles in a materials testing machine. The 225,000 cycles equals the number of paces taken by a person walking in a below knee plaster during 9 weeks. Syndesmotic fixation failure was defined as: bone fracture, screw fatigue failure, screw pullout, and/or excessive syndesmotic widening. None of the 14 out of 16 successfully tested legs or screws failed. No difference was found in fixation of the syndesmosis when stainless steel screws were compared to titanium screws through three or four cortices. Mean lateral displacement found after testing was 1.05 mm (S.D. = 0.42). This increase in tibiofibular width exceeds values described in literature for the intact syndesmosis loaded with body weight. Based on this laboratory study it is concluded that the syndesmotic set screw cannot prevent excessive syndesmotic widening when loaded with a load comparable with body weight. Therefore, we advise that patients with a syndesmotic set screw in situ should not bear weight.

  8. Differential impact of partial cortical blindness on gaze strategies when sitting and walking - an immersive virtual reality study

    PubMed Central

    Iorizzo, Dana B.; Riley, Meghan E.; Hayhoe, Mary; Huxlin, Krystel R.

    2011-01-01

    The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ~80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ~90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. PMID:21414339

  9. Differential impact of partial cortical blindness on gaze strategies when sitting and walking - an immersive virtual reality study.

    PubMed

    Iorizzo, Dana B; Riley, Meghan E; Hayhoe, Mary; Huxlin, Krystel R

    2011-05-25

    The present experiments aimed to characterize the visual performance of subjects with long-standing, unilateral cortical blindness when walking in a naturalistic, virtual environment. Under static, seated testing conditions, cortically blind subjects are known to exhibit compensatory eye movement strategies. However, they still complain of significant impairment in visual detection during navigation. To assess whether this is due to a change in compensatory eye movement strategy between sitting and walking, we measured eye and head movements in subjects asked to detect peripherally-presented, moving basketballs. When seated, cortically blind subjects detected ∼80% of balls, while controls detected almost all balls. Seated blind subjects did not make larger head movements than controls, but they consistently biased their fixation distribution towards their blind hemifield. When walking, head movements were similar in the two groups, but the fixation bias decreased to the point that fixation distribution in cortically blind subjects became similar to that in controls - with one major exception: at the time of basketball appearance, walking controls looked primarily at the far ground, in upper quadrants of the virtual field of view; cortically blind subjects looked significantly more at the near ground, in lower quadrants of the virtual field. Cortically blind subjects detected only 58% of the balls when walking while controls detected ∼90%. Thus, the adaptive gaze strategies adopted by cortically blind individuals as a compensation for their visual loss are strongest and most effective when seated and stationary. Walking significantly alters these gaze strategies in a way that seems to favor walking performance, but impairs peripheral target detection. It is possible that this impairment underlies the experienced difficulty of those with cortical blindness when navigating in real life. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Biomechanical analysis of fixation of middle third fractures of the clavicle.

    PubMed

    Drosdowech, Darren S; Manwell, Stuart E E; Ferreira, Louis M; Goel, Danny P; Faber, Kenneth J; Johnson, James A

    2011-01-01

    This biomechanical study compares four different techniques of fixation of middle third clavicular fractures. Twenty fresh-frozen clavicles were randomized into four groups. Each group used a different fixation device (3.5 Synthes reconstruction plate, 3.5 Synthes limited contact dynamic compression plate, 3.5 Synthes locking compression plate, and 4.5 DePuy Rockwood clavicular pin). All constructs were mechanically tested in bending and torque modes both with and without a simulated inferior cortical defect. Bending load to failure was also conducted. The four groups were compared using an analysis of variance test. The plate constructs were stiffer than the pin during both pure bending and torque loads with or without an inferior cortical defect. Bending load to failure with an inferior cortical defect revealed that the reconstruction plate was weaker compared with the other three groups. The limited contact and locking plates were stiffer than the reconstruction plate but demonstrated statistical significance only with the cortical defect. As hypothesized, the 3.5 limited contact dynamic compression plate and 3.5 locking compression plate demonstrated the greatest resistance to bending and torque loads, especially in the presence of simulated comminution of a middle third clavicular fracture. The reconstruction plate demonstrated lower stiffness and strength values compared with the other plates, especially with a cortical defect, whereas the pin showed poor resistance to bending and torque loads in all modes of testing. This information may help surgeons to choose the most appropriate method of fixation when treating fractures of the middle third of the clavicle.

  11. Fixating at far distance shortens reaction time to peripheral visual stimuli at specific locations.

    PubMed

    Kokubu, Masahiro; Ando, Soichi; Oda, Shingo

    2018-01-18

    The purpose of the present study was to examine whether the fixation distance in real three-dimensional space affects manual reaction time to peripheral visual stimuli. Light-emitting diodes were used for presenting a fixation point and four peripheral visual stimuli. The visual stimuli were located at a distance of 45cm and at 25° in the left, right, upper, and lower directions from the sagittal axis including the fixation point. Near (30cm), Middle (45cm), Far (90cm), and Very Far (300cm) fixation distance conditions were used. When one of the four visual stimuli was randomly illuminated, the participants released a button as quickly as possible. Results showed that overall peripheral reaction time decreased as the fixation distance increased. The significant interaction between fixation distance and stimulus location indicated that the effect of fixation distance on reaction time was observed at the left, right, and upper locations but not at the lower location. These results suggest that fixating at far distance would contribute to faster reaction and that the effect is specific to locations in the peripheral visual field. The present findings are discussed in terms of viewer-centered representation, the focus of attention in depth, and visual field asymmetry related to neurological and psychological aspects. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Influence of cement compressive strength and porosity on augmentation performance in a model of orthopedic screw pull-out.

    PubMed

    Pujari-Palmer, Michael; Robo, Celine; Persson, Cecilia; Procter, Philip; Engqvist, Håkan

    2018-01-01

    Disease and injuries that affect the skeletal system may require surgical intervention and internal fixation, i.e. orthopedic plate and screw insertion, to stabilize the injury and facilitate tissue repair. If the surrounding bone quality is poor the screws may migrate, or the bone may fail, resulting in fixation failure. While numerous studies have shown that cement augmentation of the interface between bone and implant can increase screw pull-out force, the physical properties of cement that influence pull-out force have not been investigated. The present study sought to determine how the physical properties of high strength calcium phosphate cements (hsCPCs, specifically dicalcium phosphate) affected the corresponding orthopedic screw pull-out force in urethane foam models of "healthy" and "osteoporotic" synthetic bone (Sawbones). In the simplest model, where only the bond strength between screw thread and cement (without Sawbone) was tested, the correlation between pull-out force and cement compressive strength (R 2 = 0.79) was weaker than correlation with total cement porosity (R 2 = 0.89). In open pore Sawbone that mimics "healthy" cancellous bone density the stronger cements produced higher pull-out force (50-60% increase). High strength, low porosity cements also produced higher pull-out forces (50-190% increase) in "healthy" Sawbones with cortical fixation if the failure strength of the cortical material was similar to, or greater than (a metal shell), actual cortical bone. This result is of particular clinical relevance where fixation with a metal plate implant is indicated, as the nearby metal can simulate a thicker cortical shell, thereby increasing the pull-out force of screws augmented with stronger cements. The improvement in pull-out force was apparent even at low augmentation volumes of 0.5mL (50% increase), which suggest that in clinical situations where augmentation volume is limited the stronger, lower porosity calcium phosphate cement (CPC) may still produce a significant improvement in screw pull-out force. When the correlation strength of all the tested models were compared both cement porosity and compressive strength accurately predicted pull-out force (R 2 =1.00, R 2 =0.808), though prediction accuracy depended upon the strength of the material surrounding the Sawbone. The correlations strength was low for bone with no, or weak, cortical fixation (R 2 =0.56, 0.36). Higher strength and lower porosity CPCs also produced greater pull-out force (1-1.5kN) than commercial CPC (0.2-0.5kN), but lower pull-out force than PMMA (2-3kN). The results of this study suggest that the likelihood of screw fixation failure may be reduced by selecting calcium phosphate cements with lower porosity and higher compressive strength, in patients with healthy bone mineral density and/or sufficient cortical thickness. This is of particular clinical relevance when fixation with metal plates is indicated, or where the augmentation volume is limited. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Chromatic discrimination: differential contributions from two adapting fields

    PubMed Central

    Cao, Dingcai; Lu, Yolanda H.

    2012-01-01

    To test whether a retinal or cortical mechanism sums contributions from two adapting fields to chromatic discrimination, L/M discrimination was measured with a test annulus surrounded by an inner circular field and an outer rectangular field. A retinal summation mechanism predicted that the discrimination pattern would not change with a change in the fixation location. Therefore, the fixation was set either in the inner or the outer field in two experiments. When one of the adapting fields was “red” and the other was “green,” the adapting field where the observer fixated always had a stronger influence on chromatic discrimination. However, when one adapting field was “white” and the other was red or green, the white field always weighted more heavily than the other adapting field in determining discrimination thresholds, whether the white field or the fixation was in the inner or outer adapting field. These results suggest that a cortical mechanism determines the relative contributions from different adapting fields. PMID:22330364

  14. Chromatic discrimination: differential contributions from two adapting fields.

    PubMed

    Cao, Dingcai; Lu, Yolanda H

    2012-02-01

    To test whether a retinal or cortical mechanism sums contributions from two adapting fields to chromatic discrimination, L/M discrimination was measured with a test annulus surrounded by an inner circular field and an outer rectangular field. A retinal summation mechanism predicted that the discrimination pattern would not change with a change in the fixation location. Therefore, the fixation was set either in the inner or the outer field in two experiments. When one of the adapting fields was "red" and the other was "green," the adapting field where the observer fixated always had a stronger influence on chromatic discrimination. However, when one adapting field was "white" and the other was red or green, the white field always weighted more heavily than the other adapting field in determining discrimination thresholds, whether the white field or the fixation was in the inner or outer adapting field. These results suggest that a cortical mechanism determines the relative contributions from different adapting fields. © 2012 Optical Society of America

  15. Biomechanics of far cortical locking.

    PubMed

    Bottlang, Michael; Feist, Florian

    2011-02-01

    The development of far cortical locking (FCL) was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biologic fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have been shown to enhance fixation and healing of fractures: flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80% to 88% to actively promote callus proliferation similar to an external fixator. Load is evenly distributed between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by the S-shaped flexion of FCL screws promotes symmetric callus formation. In combination, these features of FCL constructs have been shown to induce more callus and to yield significantly stronger and more consistent healing compared with standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biologic healing response of external fixators.

  16. Spatial attention improves reliability of fMRI retinotopic mapping signals in occipital and parietal cortex

    PubMed Central

    Bressler, David W.; Silver, Michael A.

    2010-01-01

    Spatial attention improves visual perception and increases the amplitude of neural responses in visual cortex. In addition, spatial attention tasks and fMRI have been used to discover topographic visual field representations in regions outside visual cortex. We therefore hypothesized that requiring subjects to attend to a retinotopic mapping stimulus would facilitate the characterization of visual field representations in a number of cortical areas. In our study, subjects attended either a central fixation point or a wedge-shaped stimulus that rotated about the fixation point. Response reliability was assessed by computing coherence between the fMRI time series and a sinusoid with the same frequency as the rotating wedge stimulus. When subjects attended to the rotating wedge instead of ignoring it, the reliability of retinotopic mapping signals increased by approximately 50% in early visual cortical areas (V1, V2, V3, V3A/B, V4) and ventral occipital cortex (VO1) and by approximately 75% in lateral occipital (LO1, LO2) and posterior parietal (IPS0, IPS1 and IPS2) cortical areas. Additionally, one 5-minute run of retinotopic mapping in the attention-to-wedge condition produced responses as reliable as the average of three to five (early visual cortex) or more than five (lateral occipital, ventral occipital, and posterior parietal cortex) attention-to-fixation runs. These results demonstrate that allocating attention to the retinotopic mapping stimulus substantially reduces the amount of scanning time needed to determine the visual field representations in occipital and parietal topographic cortical areas. Attention significantly increased response reliability in every cortical area we examined and may therefore be a general mechanism for improving the fidelity of neural representations of sensory stimuli at multiple levels of the cortical processing hierarchy. PMID:20600961

  17. Ankle fracture syndesmosis fixation and management: the current practice of orthopedic surgeons.

    PubMed

    Bava, Eric; Charlton, Timothy; Thordarson, David

    2010-05-01

    There is a wide variety of treatments for disruption of the syndesmosis. There is also controversy as to which device should be used for fixation of the syndesmosis, how many devices should be used, how many cortices the screws should engage, and whether, when, and where the screws should be removed. We conducted a study to determine how orthopedic surgeons manage these injuries. In a survey, we asked orthopedic trauma and foot and ankle fellowship directors and members of the Orthopaedic Trauma Association and the American Orthopaedic Foot and Ankle Society how they routinely treated the syndesmotic injury component of Danis-Weber type C or Lauge-Hansen pronation-external rotation type IV ankle fractures. The overall response rate was 50% (77/153). Fifty-one percent of respondents routinely used 3.5-mm cortical screws, 24% routinely used 4.5-mm cortical screws, and 14% routinely used a suture fixation device. Forty-four percent of respondents routinely used 1 screw, 44% routinely used 2 screws, and the rest were undecided between 1 and 2 screws. Twenty-nine percent of respondents engaged 3 cortices with syndesmotic screws, and 67% engaged 4 cortices. Syndesmotic screws were routinely removed 65% of the time and left in place 35% of the time. Routine removal of syndesmotic screws was done in the operating room in 95% of cases; it was done at 3 months in 49% of cases, at 4 months in 37%, and at 6 months in 12%. The most common method for treating syndesmotic injuries was through use of 3.5-mm screws engaging 4 cortices routinely removed in the operating room at 3 months. Number of screws used to fix the syndesmosis, either 1 or 2, was evenly split.

  18. External fixation of proximal tracheal airway stents: a modified technique.

    PubMed

    Majid, Adnan; Fernandez-Bussy, Sebastian; Kent, Michael; Folch, Erik; Fernandez, Liliana; Cheng, George; Gangadharan, Sidhu P

    2012-06-01

    Treatment of subglottic and proximal tracheal stenosis for nonsurgical candidates includes tracheostomy, Montgomery T tubes, and silicone stents. When used in lesions with concomitant malacia, silicone stents have a high incidence of migration. We describe a simple and effective technique of securing endoluminal stents using an Endo Close suturing device (Coviden, Boston, MA) and an external silicone button in 9 consecutive patients. Copyright © 2012 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Evaluation and treatment recommendations for acute injuries to the ankle syndesmosis without associated fracture.

    PubMed

    Miller, Timothy L; Skalak, Timothy

    2014-02-01

    Ankle ligamentous injuries are commonly seen in athletes in a variety of sports. Surveys of physicians and trainers of professional sports teams have identified syndesmotic injuries as among the most difficult to treat. In particular, injuries of the ankle syndesmosis have been strongly linked with a prolonged recovery and increased time to return to play. Due to sudden external rotation with the tibiotalar joint in dorsiflexion, these structures are commonly injured in association with fractures of the distal fibula. Surgery is indicated in cases with associated fractures and ligamentous instability, but optimal treatment for syndesmosis injuries without an associated fracture is less clear. A thorough history and physical examination, as well as appropriate imaging, are necessary to effectively diagnose and classify the injury. For stable injuries, short-term immobilization and functional rehabilitation is recommended. Unstable Grade 2 and 3 injuries require surgical fixation. Debate currently exists over rigid screw fixation versus suture button techniques as the ideal fixation method.

  20. The stability of mandibular prognathism corrected by bilateral sagittal split osteotomies: a comparison of bi-cortical osteosynthesis and mono-cortical osteosynthesis.

    PubMed

    Hsu, S S-P; Huang, C-S; Chen, P K-T; Ko, E W-C; Chen, Y-R

    2012-02-01

    This study evaluated the differences in surgical changes and post-surgical changes between bi-cortical and mono-cortical osteosynthesis (MCO) in the correction of skeletal Class III malocclusion with bilateral sagittal split osteotomies (BSSOs). Twenty-five patients had bi-cortical osteosynthesis (BCO), 32 patients had mono-cortical fixation. Lateral and postero-anterior cephalometric radiographs, taken at the time of surgery, before surgery, 1 month after surgery, and on completion of orthodontic treatment (mean 9.9 months after surgery), were obtained for evaluation. Cephalometric analysis and superimposition were used to investigate the surgical and post-surgical changes. Independent t-test was performed to compare the difference between the two groups. Pearson's correlations were tested to evaluate the factors related to the relapse of the mandible. The sagittal relapse rate was 20% in the bi-cortical and 25% in the mono-cortical group. The forward-upward rotation of the mandible in the post-surgical period contributed most of the sagittal relapse. There were no statistically significant differences in sagittal and vertical changes between the two groups during surgery and in the post-surgical period. No factors were found to correlate with post-surgical relapse, but the intergonial width increased more in the bi-cortical group. The study suggested that both methods of skeletal fixation had similar postoperative stability. Copyright © 2011 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Assessment of the Biomechanical Performance of 5 Plating Techniques in Fixation of Mandibular Subcondylar Fracture Using Finite Element Analysis.

    PubMed

    Darwich, Mhd Ayham; Albogha, Mhd Hassan; Abdelmajeed, Adnan; Darwich, Khaldoun

    2016-04-01

    The aim of this study was to compare the performances of 5 plating techniques for fixation of unilateral mandibular subcondylar fracture. Five titanium plating techniques for fixation of condylar fracture were analyzed using the finite element method. The modeled techniques were 1) 1 straight plate, 2) 2 parallel straight plates, 3) 2 angulated straight plates, 4) 1 trapezoidal plate, and 5) 1 square plate. Three-dimensional models were generated using patient-specific geometry for the mandible obtained from a computerized tomographic image of a healthy living man. Plates were designed and combined with the mandible and analyzed under a 500-N load. The single straight plate presented the most inferior performance; it presented maximum displacement and strain on cortical bone. The trapezoidal plate induced the least amount of strain on cortical bone and was best at resisting displacement. The trapezoidal plate is recommended for fixation of subcondylar fracture. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Tension degradation of anterior cruciate ligament grafts with dynamic flexion-extension loading: a biomechanical model in porcine knees.

    PubMed

    Dargel, Jens; Koebke, Jürgen; Brüggemann, Gert-Peter; Pennig, Dietmar; Schmidt-Wiethoff, Rüdiger

    2009-10-01

    This study investigates the influence of various femoral anterior cruciate ligament graft fixation methods on the amount of tension degradation and the initial fixation strength after cyclic flexion-extension loading in a porcine knee model. One hundred twenty porcine digital extensor tendons, used as 4-stranded free tendon grafts, were fixated within porcine femoral bone tunnels by use of extracortical button, cross-pin, or interference screw fixation. One hundred twenty porcine patellar tendon-bone grafts were fixated by use of cross-pin, interference screw, or press-fit fixation. Each femur-graft complex was submitted to cyclic flexion-extension loading for 1,000 cycles throughout different loading ranges, and the total loss of tension was determined. After cyclic testing, the grafts were loaded to failure, and the data were compared with a pullout series without cyclic loading. Tension degradation after 1,000 cycles of flexion-extension loading averaged 62.6% +/- 10.0% in free tendon grafts and 48.9% +/- 13.35% in patellar tendon-bone grafts. There was no influence of the loading range on the total amount of tension degradation. The total amount of tension degradation was the highest with interference screw fixation of free tendon and patellar tendon-bone grafts. Despite excessive loss of tension, the initial fixation strength of the femur-graft complex was not reduced. The method of femoral graft fixation significantly influenced tension degradation during dynamic flexion-extension loading. Femoral graft fixation methods that secure the graft close to the tunnel entrance and that displace the graft substance from the center of the bone tunnel show the largest amount of tension degradation during cyclic flexion-extension loading. The graft substance, not the fixation site, was the weakest link of the graft complex within this investigation. We believe that the graft fixation method should be considered when aiming to improve the precision of femoral graft placement in anterior cruciate ligament reconstruction.

  3. Scene perception in posterior cortical atrophy: categorization, description and fixation patterns.

    PubMed

    Shakespeare, Timothy J; Yong, Keir X X; Frost, Chris; Kim, Lois G; Warrington, Elizabeth K; Crutch, Sebastian J

    2013-01-01

    Partial or complete Balint's syndrome is a core feature of the clinico-radiological syndrome of posterior cortical atrophy (PCA), in which individuals experience a progressive deterioration of cortical vision. Although multi-object arrays are frequently used to detect simultanagnosia in the clinical assessment and diagnosis of PCA, to date there have been no group studies of scene perception in patients with the syndrome. The current study involved three linked experiments conducted in PCA patients and healthy controls. Experiment 1 evaluated the accuracy and latency of complex scene perception relative to individual faces and objects (color and grayscale) using a categorization paradigm. PCA patients were both less accurate (faces < scenes < objects) and slower (scenes < objects < faces) than controls on all categories, with performance strongly associated with their level of basic visual processing impairment; patients also showed a small advantage for color over grayscale stimuli. Experiment 2 involved free description of real world scenes. PCA patients generated fewer features and more misperceptions than controls, though perceptual errors were always consistent with the patient's global understanding of the scene (whether correct or not). Experiment 3 used eye tracking measures to compare patient and control eye movements over initial and subsequent fixations of scenes. Patients' fixation patterns were significantly different to those of young and age-matched controls, with comparable group differences for both initial and subsequent fixations. Overall, these findings describe the variability in everyday scene perception exhibited by individuals with PCA, and indicate the importance of exposure duration in the perception of complex scenes.

  4. Mechanical characteristics of the new BONE-LOK bi-cortical internal fixation device.

    PubMed

    Cachia, Victor V; Shumway, Don; Culbert, Brad; Padget, Marty

    2003-01-01

    The purpose of this study was to evaluate the mechanical characteristics of a new and unique titanium compression anchor with BONE-LOK (Triage Medical, Inc, Irvine, CA) technology for compressive, bi-cortical internal fixation of bone. This device provides fixation through the use of a distal grasping anchor and an adjustable proximal collar that are joined by an axially movable pin and guide wire. The titanium compression anchor, in 2.0-, 2.7-, and 3.5-mm diameters, were compared with cortex screws (Synthes USA, Paoli, PA) of the same diameter and material for pullout strength in 20 lb/cu ft and 30 lb/cu ft solid rigid polyurethane foam; and for compression strength in 20 lb/cu ft foam. Retention strength of the collar was tested independently. The results showed significantly greater pullout strength of the 2.7-mm and 3.5-mm titanium compression anchor as compared with the 2.7-mm and 3.5-mm cortex screws in these test models. Pullout strength of the 2.0-mm titanium compression anchor was not statistically different in comparison with the 2.0-mm cortical screws. Compression strength of the titanium compression anchor was significantly greater than the cortical screws for all diameters tested. These differences represent a distinct advantage with the new device, which warrants further in vivo testing. Collar retention strength testing values were obtained for reference only and have no comparative significance.

  5. Human factors in equipment development for the Space Shuttle - A study of the general purpose work station

    NASA Technical Reports Server (NTRS)

    Junge, M. K.; Giacomi, M. J.

    1981-01-01

    The results of a human factors test to assay the suitability of a prototype general purpose work station (GPWS) for biosciences experiments on the fourth Spacelab mission are reported. The evaluation was performed to verify that users of the GPWS would optimally interact with the GPWS configuration and instrumentation. Six male subjects sat on stools positioned to allow assimilation of the zero-g body posture. Trials were run concerning the operator viewing angles facing the console, the console color, procedures for injecting rates with dye, a rat blood cell count, mouse dissection, squirrel monkey transfer, and plant fixation. The trials were run for several days in order to gage improvement or poor performance conditions. Better access to the work surface was found necessary, together with more distinct and better located LEDs, better access window latches, clearer sequences on control buttons, color-coded sequential buttons, and provisions made for an intercom system when operators of the GPWS work in tandem.

  6. Accuracy of screw fixation using the O-arm® and StealthStation® navigation system for unstable pelvic ring fractures.

    PubMed

    Takeba, Jun; Umakoshi, Kensuke; Kikuchi, Satoshi; Matsumoto, Hironori; Annen, Suguru; Moriyama, Naoki; Nakabayashi, Yuki; Sato, Norio; Aibiki, Mayuki

    2018-04-01

    Screw fixation for unstable pelvic ring fractures is generally performed using the C-arm. However, some studies reported erroneous piercing with screws, nerve injuries, and vessel injuries. Recent studies have reported the efficacy of screw fixations using navigation systems. The purpose of this retrospective study was to investigate the accuracy of screw fixation using the O-arm ® imaging system and StealthStation ® navigation system for unstable pelvic ring fractures. The participants were 10 patients with unstable pelvic ring fractures, who underwent screw fixations using the O-arm StealthStation navigation system (nine cases with iliosacral screw and one case with lateral compression screw). We investigated operation duration, bleeding during operation, the presence of complications during operation, and the presence of cortical bone perforation by the screws based on postoperative CT scan images. We also measured the difference in screw tip positions between intraoperative navigation screen shot images and postoperative CT scan images. The average operation duration was 71 min, average bleeding was 12 ml, and there were no nerve or vessel injuries during the operation. There was no cortical bone perforation by the screws. The average difference between intraoperative navigation images and postoperative CT images was 2.5 ± 0.9 mm, for all 18 screws used in this study. Our results suggest that the O-arm StealthStation navigation system provides accurate screw fixation for unstable pelvic ring fractures.

  7. Relative stability of tension band versus two-cortex screw fixation for treating fifth metatarsal base avulsion fractures.

    PubMed

    Husain, Z S; DeFronzo, D J

    2000-01-01

    This study assesses the strength of fixating avulsion fractures of the fifth metatarsal base with a 4.0-mm partially threaded cancellous screw crossing two cortices as compared to tension banding. Our data showed statistically significant fixation strength improvement over tension banding for avulsion fractures (p < 0.02) in both polystyrene foam models and fresh, nonpreserved frozen cadaveric samples. In cadavers, the screw fixations were able to withstand more than three times the load sustained by the tension band fixations. The study utilized the Instron 8500 tensiometer to apply physiologic loads to test the constructs until failure. The displacement and load data at failure show the limitations of both fixations. By increasing the load resistance while maintaining compression, the bicortical cancellous screw fixation created greater stability at the avulsion fracture of the fifth metatarsal base as compared to tension band stabilization.

  8. Scene perception in posterior cortical atrophy: categorization, description and fixation patterns

    PubMed Central

    Shakespeare, Timothy J.; Yong, Keir X. X.; Frost, Chris; Kim, Lois G.; Warrington, Elizabeth K.; Crutch, Sebastian J.

    2013-01-01

    Partial or complete Balint's syndrome is a core feature of the clinico-radiological syndrome of posterior cortical atrophy (PCA), in which individuals experience a progressive deterioration of cortical vision. Although multi-object arrays are frequently used to detect simultanagnosia in the clinical assessment and diagnosis of PCA, to date there have been no group studies of scene perception in patients with the syndrome. The current study involved three linked experiments conducted in PCA patients and healthy controls. Experiment 1 evaluated the accuracy and latency of complex scene perception relative to individual faces and objects (color and grayscale) using a categorization paradigm. PCA patients were both less accurate (faces < scenes < objects) and slower (scenes < objects < faces) than controls on all categories, with performance strongly associated with their level of basic visual processing impairment; patients also showed a small advantage for color over grayscale stimuli. Experiment 2 involved free description of real world scenes. PCA patients generated fewer features and more misperceptions than controls, though perceptual errors were always consistent with the patient's global understanding of the scene (whether correct or not). Experiment 3 used eye tracking measures to compare patient and control eye movements over initial and subsequent fixations of scenes. Patients' fixation patterns were significantly different to those of young and age-matched controls, with comparable group differences for both initial and subsequent fixations. Overall, these findings describe the variability in everyday scene perception exhibited by individuals with PCA, and indicate the importance of exposure duration in the perception of complex scenes. PMID:24106469

  9. An in vitro biomechanical comparison of hydroxyapatite coated and uncoated ao cortical bone screws for a limited contact: dynamic compression plate fixation of osteotomized equine 3rd metacarpal bones.

    PubMed

    Durham, Myra E; Sod, Gary A; Riggs, Laura M; Mitchell, Colin F

    2015-02-01

    To compare the monotonic biomechanical properties of a broad 4.5 mm limited contact-dynamic compression plate (LC-DCP) fixation secured with hydroxyapatite (HA) coated cortical bone screws (HA-LC-DCP) versus uncoated cortical bone screws (AO-LC-DCP) to repair osteotomized equine 3rd metacarpal (MC3) bones. Experimental. Adult equine cadaveric MC3 bones (n = 12 pair). Twelve pairs of equine MC3 were divided into 3 test groups (4 pairs each) for: (1) 4 point bending single cycle to failure testing; (2) 4 point bending cyclic fatigue testing; and (3) torsional single cycle to failure testing. For the HA-LC-DCP-MC3 construct, an 8-hole broad LC-DCP (Synthes Ltd, Paoli, PA) was secured on the dorsal surface of each randomly selected MC3 bone with a combination of four 5.5 mm and four 4.5 mm HA-coated cortical screws. For the AO-LC-DCP-MC3 construct, an 8-hole 4.5 mm broad LC-DCP was secured on the dorsal surface of the contralateral MC3 bone with a combination of four 5.5 mm and four 4.5 mm uncoated cortical screws. All MC3 bones had mid-diaphyseal osteotomies. Mean test variable values for each method were compared using a paired t-test within each group. Significance was set at P < .05. Mean yield load, yield bending moment, composite rigidity, failure load, and failure bending moment, under 4 point bending, single cycle to failure, of the HA-LC-DCP fixation were significantly greater than those of the AO-LC-DCP fixation. Mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, in single cycle to failure under 4 point bending were: yield load, 26.7 ± 2.15 and 16.3 ± 1.38 kN; yield bending moment, 527.4 ± 42.4 and 322.9 ± 27.2 N-m; composite rigidity, 5306 ± 399 and 3003 ± 300 N-m/rad; failure load, 40.6 ± 3.94 and 26.5 ± 2.52 kN; and failure bending moment, 801.9 ± 77.9 and 522.9 ± 52.2 N-m. Mean cycles to failure in 4 point bending of the HA-LC-DCP fixation (116,274 ± 13,211) was significantly greater than that of the AO-LC-DCP fixation 47,619 ± 6580. Mean yield load, mean composite rigidity, and mean failure load under torsional testing, single cycle to failure was significantly greater for the broad HA-LC-DCP fixation compared with the AO-LC-DCP fixation. In single cycle to failure under torsion, mean ± SD values for the HA-LC-DCP and the AO-LC-DCP fixation techniques, respectively, were: yield load, 101.3 ± 14.68 and 70.54 ± 10.20 N-m; composite rigidity, 437.9 ± 32.9 and 220.7 ± 17.6 N-m/rad; and failure load: 105.7 ± 15.5 and 75.28 ± 10.1 N-m. HA-LC-DCP was superior to AO-LC-DCP in resisting the static overload forces (palmarodorsal 4 point bending and torsional) and in resisting cyclic fatigue under palmarodorsal 4 point bending. © Copyright 2014 by The American College of Veterinary Surgeons.

  10. Decreased functional brain activation in Friedreich ataxia using the Simon effect task.

    PubMed

    Georgiou-Karistianis, N; Akhlaghi, H; Corben, L A; Delatycki, M B; Storey, E; Bradshaw, J L; Egan, G F

    2012-08-01

    The present study applied the Simon effect task to examine the pattern of functional brain reorganization in individuals with Friedreich ataxia (FRDA), using functional magnetic resonance imaging (fMRI). Thirteen individuals with FRDA and 14 age and sex matched controls participated, and were required to respond to either congruent or incongruent arrow stimuli, presented either to the left or right of a screen, via laterally-located button press responses. Although the Simon effect (incongruent minus congruent stimuli) showed common regions of activation in both groups, including the superior and middle prefrontal cortices, insulae, superior and inferior parietal lobules (LPs, LPi), occipital cortex and cerebellum, there was reduced functional activation across a range of brain regions (cortical, subcortical and cerebellar) in individuals with FRDA. The greater Simon effect behaviourally in individuals with FRDA, compared with controls, together with concomitant reductions in functional brain activation and reduced functional connectivity between cortical and sub-cortical regions, implies a likely disruption of cortico-cerebellar loops and ineffective engagement of cognitive/attention regions required for response suppression. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. A prospective randomized multicenter trial comparing clinical outcomes of patients treated surgically with a static or dynamic implant for acute ankle syndesmosis rupture.

    PubMed

    Laflamme, Mélissa; Belzile, Etienne L; Bédard, Luc; van den Bekerom, Michel P J; Glazebrook, Mark; Pelet, Stéphane

    2015-05-01

    To compare the clinical and radiographic outcome after stabilization of an acute syndesmosis rupture with either a static implant (a 3.5-mm metallic screw through 4 cortices) or a dynamic device (TightRope; Arthrex). Multicenter randomized double-blind controlled trial. Study realized in 5 trauma centers (2 level 1 and 3 level 2) in 2 countries. Seventy subjects admitted for an acute ankle syndesmosis rupture entered the study and were randomized into 2 groups (dynamic fixation = 34 and static fixation = 36). The 2 groups were similar regarding demographic, social, and surgical data. Sixty-five patients (dynamic = 33 and static = 32) completed the study and were available for analysis. Syndesmosis fixation in the static group was realized with a 4 cortices 3.5-mm cortical screw (Synthes) and in the dynamic group with 1 TightRope (Arthrex). Standardized rehabilitation process for the 2 groups: no weight bearing in a cast for 6 weeks and then rehabilitation without protection. Olerud-Molander score. Subjects with dynamic fixation achieved better clinical performances as described with the Olerud-Molander scores at 3 (68.8 vs. 60.2, P = 0.067), 6 (84.2 vs. 76.8, P = 0.082), and 12 months (93.3 vs. 87.6, P = 0.046). We also observed higher American Orthopaedic Foot and Ankle Society scores at 3 months (78.6 vs. 70.6, P = 0.016), but these were not significant at 6 (87.1 vs. 83.8, P = 0.26) or 12 months (93.1 vs. 89.9, P = 0.26). Implant failure was higher in the screw group (36.1% vs. 0%, P < 0.05). Loss of reduction was observed in 4 cases in the static screw group (11.1% vs. 0%, P = 0.06). Dynamic fixation of acute ankle syndesmosis rupture with a dynamic device seems to result in better clinical and radiographic outcomes. The implant offers adequate syndesmotic stabilization without failure or loss of reduction, and the reoperation rate is significantly lower than with conventional screw fixation. Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

  12. A retrospective comparative study of arthroscopic fixation in acute Rockwood type IV acromioclavicular joint dislocation: single versus double paired Endobutton technique.

    PubMed

    Xu, Jian; Liu, Haifeng; Lu, Wei; Li, Dingfu; Zhu, Weimin; Ouyang, Kan; Wu, Bing; Peng, Liangquan; Wang, Daping

    2018-05-24

    Rockwood type IV acromioclavicular joint (ACJ) dislocation is a trauma usually needs surgical treatment. Paired EndoButton technique (PET) is used in treating such condition. However, the effect of using different types of PET (single versus double PET) for fixation remains controversial. This study aims to evaluate and compare the efficacy of single and double PET and to provide a suitable option for the surgeons. We retrospectively reviewed the charts of patients with acute Rockwood type IV ACJ dislocation who had undergone arthroscopic fixation using single or double PET fixation between March 2009 and March 2015. Seventy-eight consecutive patients identified from chart review were picked and were divided into the single and double PET group with 39 cases in each group. The indexes of visual analog scale score (VAS) for pain, the radiographs of the affected shoulder at different time points of the follow-up, the time of return to activities and sports, the constant functional score, and the Karlsson acromioclavicular joint (ACJ) score, were assessed in a minimum of 2 years postoperation. The average coracoclavicular (CC) and acromioclavicular (AC) distances of the affected joints in the double PET group were significantly smaller than those of the single PET group 2 years postoperation (P < 0.05). The average AC and CC distances in the healthy shoulder joints were significantly smaller than those of the affected joints in the single PET group (P < 0.05); however, these values were not significantly different from those of the affected joints in the double PET group (P > 0.05). The mean VAS pain score was not significantly different, while significant difference was found for the number and times of cases return to activities and sports, constant functional score, and Karlsson ACJ score (P < 0.05) between the two groups. Therefore, the double PET group has better outcome than the single PET group. Complications including redislocation, button slippage, erosion, or AC joint instability occurred in the single PET group, while the complication in the double PET group was rare. Compared with the single PET, the double PET group achieved better outcome with less complications in arthroscopically treating acute Rockwood type IV ACJ dislocation.

  13. Biomechanical evaluation of a transtibial pull-out meniscal root repair: challenging the bungee effect.

    PubMed

    Cerminara, Anthony J; LaPrade, Christopher M; Smith, Sean D; Ellman, Michael B; Wijdicks, Coen A; LaPrade, Robert F

    2014-12-01

    A common treatment for posterior meniscal root tears is transtibial pull-out repair, which has been biomechanically reported to restore tibiofemoral contact mechanics to those of the intact knee. Biomechanical data suggest that there is significant displacement of the repaired meniscal root with cyclic loading, which may be responsible for the poor healing and meniscal extrusion demonstrated in some clinical studies. The purpose of this study was to quantify the time-zero displacement of the posterior meniscal root in response to cyclic loading after transtibial pull-out repair and to quantify the individual contributions to displacement of the following: (1) suture elongation, (2) button-bone interface, and (3) meniscus-suture interface. The meniscus-suture interface was hypothesized to result in significantly more displacement than the button-bone interface or suture elongation. Descriptive laboratory study. Transtibial pull-out repair of the posterior medial meniscal root was performed in 6 porcine knees, and cyclic displacement was measured using a loading protocol representative of postoperative rehabilitation. Displacement from (1) suture elongation, (2) the button-bone interface, and (3) the meniscus-suture interface was determined by cyclically loading 6 specimens for each construct using the same loading protocol to determine the contribution of each component to the overall displacement of the repair construct. After 1000 cycles, the repair construct displaced by a mean of 3.28 mm (95% CI, 2.07-4.49). The meniscus-suture component (mean, 2.52 mm; 95% CI, 2.21-2.83) displaced significantly more than the button-bone component (mean, 0.90 mm; 95% CI, 0.64-1.15; P = .006) and suture elongation component (mean, 0.71 mm; 95% CI, 0.36-1.06; P = .006) after 1000 cycles. Displacement of the button-bone and suture elongation components was not significantly different after 1000 cycles (P = .720). There was substantial displacement of the posterior medial meniscal root repaired with the transtibial pull-out technique under a cyclic loading protocol simulating postoperative rehabilitation. The meniscus-suture interface contributed to significantly more displacement than the button-bone interface and suture elongation in the transtibial pull-out repair construct. The results provide a framework for optimizing the transtibial pull-out repair technique. Future studies should focus on improving suture fixation strength within the meniscus-suture interface. © 2014 The Author(s).

  14. Regional alterations in long bone /sup 85/Sr clearance produced by internal fixation devices. Part II. Histomorphometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simmons, D.J.; Daum, W.J.; Calhoun, J.H.

    1988-01-01

    The effects of each of the surgical stages involved in compression plating on the development of cortical thinning and porosity were assessed in the intact midshaft, stress-shielded femoral segments of adult mongrel dogs 6 months postoperatively. The data were evaluated in terms of a postsurgical tetracycline-based measure of remodeling and terminal /sup 85/Sr clearance (SrC) values for the plated segments of bone. Drilling had no effect on any parameter. Screw application was associated with minimal cortical thinning (p less than 0.05), while plate fixation clearly promoted thinning (p less than 0.01) and porosity (p less than 0.05). The percentage ofmore » labeled osteons, a measure of remodeling activity, increased only after plate fixation (p less than 0.05), and the labeling patterns suggested that most osteons had formed during the first 4 postsurgical months. That none of these changes were correlated with the 6-month SrC values suggests that the development of plate-induced osteopenia involves disparate histomorphometric time constants, rather than lack of any association.« less

  15. Comparison of volumetric bone mineral density in the tibial region of interest for ACL reconstruction.

    PubMed

    Klein, Scott A; Nyland, John; Caborn, David N M; Kocabey, Yavuz; Nawab, Akbar

    2005-12-01

    Adequate tibial bone mineral density (BMD) is essential to soft tissue graft fixation during anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to compare volumetric bone plug density measurements at the tibial region of interest for ACL reconstruction using a standardized immersion technique and Archimedes' principle. Cancellous bone cores were harvested from the proximal, middle, and distal metaphyseal regions of the lateral tibia and from the standard tibial tunnel location used for ACL reconstruction of 18 cadaveric specimens. Proximal tibial cores displayed 32.6% greater BMD than middle tibial cores and 31.8% greater BMD than distal tibial cores, but did not differ from the BMD of the tibial tunnel cores. Correlational analysis confirmed that the cancellous BMD in the tibial tunnel related to the cancellous BMD of the proximal and distal lateral tibial metaphysis. In conjunction with its adjacent cortical bone, the cancellous BMD of the region used for standard tibial tunnel placement provides an effective foundation for ACL graft fixation. In tibia with poor BMD, bicortical fixation that incorporates cortical bone from the distal tibial tunnel region is recommended.

  16. Modified tension band fixation and coracoclavicular stabilisation for unstable distal clavicle fracture.

    PubMed

    Choi, Sungwook; Kim, Sang-Rim; Kang, Hyunseong; Kim, Donghee; Park, Yong-Geun

    2015-02-01

    The purpose of this study was to report a new surgical technique for the treatment of unstable distal clavicle fracture with modified tension band fixation (MTBF) and coracoclavicular (CC) stabilisation, and evaluate the radiologic and clinical outcome of these patients. Thirteen patients who had a fracture of the distal clavicle (Neer classification type IIb) were treated with MTBF and CC stabilisation. After the CC stabilisation was performed with a suture anchor or flip button, internal fixation using MTBF was carried out. Each patient was followed up for a minimum of 12 months and their clinical and radiological results were analysed. The mean period required for fracture union was 12.6 (range, 8-24) weeks and union was successfully completed in all cases. The mean Constant score at the final follow-up was 94.7 (88-100); the modified University of California, Los Angeles (UCLA) shoulder rating scale was 31.3 points (range, 22-35). All patients returned to normal daily activities at an average of 3.7 months postoperatively (range, 3-5 months). One patient had a new fracture around drilled holes for CC stabilisation by inappropriate tunnelling. MTBF and CC stabilisation is a useful technique for treating an unstable distal clavicle fracture. This procedure provides minimal incision and stable fixation without causing any further acromioclavicular joint injury to those with distal clavicle fractures. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Biomechanical Concepts for Fracture Fixation

    PubMed Central

    Bottlang, Michael; Schemitsch, Christine E.; Nauth, Aaron; Routt, Milton; Egol, Kenneth; Cook, Gillian E.; Schemitsch, Emil H.

    2015-01-01

    Application of the correct fixation construct is critical for fracture healing and long-term stability; however, it is a complex issue with numerous significant factors. This review describes a number of common fracture types, and evaluates their currently available fracture fixation constructs. In the setting of complex elbow instability, stable fixation or radial head replacement with an appropriately sized implant in conjunction with ligamentous repair is required to restore stability. For unstable sacral fractures, “standard” iliosacral screw fixation is not sufficient for fractures with vertical or multiplanar instabilities. Periprosthetic femur fractures, in particular Vancouver B1 fractures, have increased stability when using 90/90 fixation versus a single locking plate. Far Cortical Locking combines the concept of dynamization with locked plating in order to achieve superior healing of a distal femur fracture. Finally, there is no ideal construct for syndesmotic fracture stabilization; however, these fractures should be fixed using a device that allows for sufficient motion in the syndesmosis. In general, orthopaedic surgeons should select a fracture fixation construct that restores stability and promotes healing at the fracture site, while reducing the potential for fixation failure. PMID:26584263

  18. The self adapting washer for lag screw fixation of mandibular fractures: finite element analysis and preclinical evaluation.

    PubMed

    Terheyden, H; Mühlendyck, C; Feldmann, H; Ludwig, K; Härle, F

    1999-02-01

    Besides rigid fixation, lag screws have distinct advantages compared with plates in appropriate indications in mandibular fractures. However, in current lag screw systems, the relatively small area of the screw head has to transfer the tensile force which can exceed 1000 N in the symphysis, to the thin cortical bone plate. Countersinking, which is obligatory in most systems, will weaken the cortical plate. Finite element analysis (FEA) revealed that load in this situation can exceed the normal tensile strength of metal and bone. Consequently, a new washer was constructed which both increased the supporting surface and did not require countersinking. The washer is self adapting (SAW) to the cortical plate in a defined position, forming a ball and socket joint with the screw head. Using the FEA model, a ten-fold reduction in load on bone and metal was observed with the new washer. In a miniature pig mandibular symphysis fracture model, the clinical applicability and a favourable histological reaction were demonstrated, compared with conventional lag screw designs.

  19. [Experimental study of tendon graft fixation in anterior cruciate ligament reconstruction with cortical press-fit bolt in rabbits].

    PubMed

    Qi, Wei; Li, Chun-bao; Wang, Jun-liang; Zhu, Juan-li; Liu, Yu-jie

    2013-05-21

    To explore the histological outcomes of tendon-bone healing in anterior cruciate ligament (ACL) reconstruction with cortical press-fit bolt (CPB). Twenty-four healthy female or male New Zealand White rabbits (2-3 months old) underwent bilateral ACL reconstruction with extensor digitorum longus tendon. A random method was used to decide one knee would receive the routine ACL reconstruction (control group) and another cortical press-fit bolt fixation (experimental group). After general anesthesia, extensor digitorum longus tendon was harvested and ACL reconstruction performed. All animals were sacrificed at 4, 8 and 12 weeks postoperation. Radiological and histological examinations were made at each timepoint. The specimens were stained with different methods to observe the pathological changes of tendon graft, bone tunnel and cortical press-fit bolt. More revascularization and massive new bone were found in tendon-bone junction of experimental group at 4, 8 and 12 weeks postoperation. The circum-graft new vessel proportion of the experimental and control groups were 0.48 ± 0.12 and 0.26 ± 0.05 respectively (P < 0.05). In the experimental group, more cartilage cells were present in tendon-bone junction at 12 weeks and the circum-graft new bone areas in two groups were 0.41 ± 0.11 and 0.21 ± 0.10 mm(2) respectively (P < 0.05). Cortical press-fit blot may improve tendon-bone healing after ACL reconstruction in rabbits. The application prospects of this procedure are promising.

  20. Biomechanical evaluation of three different fixation methods of the Chevron osteotomy of the olecranon: an analysis with Roentgen Stereophotogrammatic Analysis.

    PubMed

    Wagener, Marc L; Driesprong, Marco; Heesterbeek, Petra J C; Verdonschot, Nico; Eygendaal, Denise

    2013-08-01

    In this study three different methods for fixating the Chevron osteotomy of the olecranon are evaluated. Transcortical fixed Kirschner wires with a tension band, a large cancellous screw with a tension band, and a large cancellous screw alone are compared using Roentgen Stereophotogrammatic Analysis (RSA). The different fixation methods were tested in 17 cadaver specimens by applying increasing repetitive force to the triceps tendon. Forces applied were 200N, 350N, and 500N. Translation and rotation of the osteotomy were recorded using Roentgen Stereophotogrammatic Analysis. Both the fixations with a cancellous screw with tension band and with bi-cortical placed Kirschner wires with a tension band provide enough stability to withstand the forces of normal daily use. Since fixation with a cancellous screw with tension band is a fast and easy method and is related to minimal soft tissue damage this method can preferably be used for fixation of a Chevron osteotomy of the olecranon. © 2013.

  1. A new adhesive technique for internal fixation in midfacial surgery

    PubMed Central

    Endres, Kira; Marx, Rudolf; Tinschert, Joachim; Wirtz, Dieter Christian; Stoll, Christian; Riediger, Dieter; Smeets, Ralf

    2008-01-01

    Background The current surgical therapy of midfacial fractures involves internal fixation in which bone fragments are fixed in their anatomical positions with osteosynthesis plates and corresponding screws until bone healing is complete. This often causes new fractures to fragile bones while drilling pilot holes or trying to insert screws. The adhesive fixation of osteosynthesis plates using PMMA bone cement could offer a viable alternative for fixing the plates without screws. In order to achieve the adhesive bonding of bone cement to cortical bone in the viscerocranium, an amphiphilic bone bonding agent was created, analogous to the dentin bonding agents currently on the market. Methods The adhesive bonding strengths were measured using tension tests. For this, metal plates with 2.0 mm diameter screw holes were cemented with PMMA bone cement to cortical bovine bone samples from the femur diaphysis. The bone was conditioned with an amphiphilic bone bonding agent prior to cementing. The samples were stored for 1 to 42 days at 37 degrees C, either moist or completely submerged in an isotonic NaCl-solution, and then subjected to the tension tests. Results Without the bone bonding agent, the bonding strength was close to zero (0.2 MPa). Primary stability with bone bonding agent is considered to be at ca. 8 MPa. Moist storage over 42 days resulted in decreased adhesion forces of ca. 6 MPa. Wet storage resulted in relatively constant bonding strengths of ca. 8 MPa. Conclusion A new amphiphilic bone bonding agent was developed, which builds an optimizied interlayer between the hydrophilic bone surface and the hydrophobic PMMA bone cement and thus leads to adhesive bonding between them. Our in vitro investigations demonstrated the adhesive bonding of PMMA bone cement to cortical bone, which was also stable against hydrolysis. The newly developed adhesive fixing technique could be applied clinically when the fixation of osteosynthesis plates with screws is impossible. With the detected adhesion forces of ca. 6 to 8 MPa, it is assumed that the adhesive fixation system is able to secure bone fragments from the non-load bearing midfacial regions in their orthotopic positions until fracture consolidation is complete. PMID:18489785

  2. Combined effects of expectations and visual uncertainty upon detection and identification of a target in the fog.

    PubMed

    Quétard, Boris; Quinton, Jean-Charles; Colomb, Michèle; Pezzulo, Giovanni; Barca, Laura; Izaute, Marie; Appadoo, Owen Kevin; Mermillod, Martial

    2015-09-01

    Detecting a pedestrian while driving in the fog is one situation where the prior expectation about the target presence is integrated with the noisy visual input. We focus on how these sources of information influence the oculomotor behavior and are integrated within an underlying decision-making process. The participants had to judge whether high-/low-density fog scenes displayed on a computer screen contained a pedestrian or a deer by executing a mouse movement toward the response button (mouse-tracking). A variable road sign was added on the scene to manipulate expectations about target identity. We then analyzed the timing and amplitude of the deviation of mouse trajectories toward the incorrect response and, using an eye tracker, the detection time (before fixating the target) and the identification time (fixations on the target). Results revealed that expectation of the correct target results in earlier decisions with less deviation toward the alternative response, this effect being partially explained by the facilitation of target identification.

  3. Reduced modulation of scanpaths in response to task demands in posterior cortical atrophy.

    PubMed

    Shakespeare, Timothy J; Pertzov, Yoni; Yong, Keir X X; Nicholas, Jennifer; Crutch, Sebastian J

    2015-02-01

    A difficulty in perceiving visual scenes is one of the most striking impairments experienced by patients with the clinico-radiological syndrome posterior cortical atrophy (PCA). However whilst a number of studies have investigated perception of relatively simple experimental stimuli in these individuals, little is known about multiple object and complex scene perception and the role of eye movements in posterior cortical atrophy. We embrace the distinction between high-level (top-down) and low-level (bottom-up) influences upon scanning eye movements when looking at scenes. This distinction was inspired by Yarbus (1967), who demonstrated how the location of our fixations is affected by task instructions and not only the stimulus' low level properties. We therefore examined how scanning patterns are influenced by task instructions and low-level visual properties in 7 patients with posterior cortical atrophy, 8 patients with typical Alzheimer's disease, and 19 healthy age-matched controls. Each participant viewed 10 scenes under four task conditions (encoding, recognition, search and description) whilst eye movements were recorded. The results reveal significant differences between groups in the impact of test instructions upon scanpaths. Across tasks without a search component, posterior cortical atrophy patients were significantly less consistent than typical Alzheimer's disease patients and controls in where they were looking. By contrast, when comparing search and non-search tasks, it was controls who exhibited lowest between-task similarity ratings, suggesting they were better able than posterior cortical atrophy or typical Alzheimer's disease patients to respond appropriately to high-level needs by looking at task-relevant regions of a scene. Posterior cortical atrophy patients had a significant tendency to fixate upon more low-level salient parts of the scenes than controls irrespective of the viewing task. The study provides a detailed characterisation of scene perception abilities in posterior cortical atrophy and offers insights into the mechanisms by which high-level cognitive schemes interact with low-level perception. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. [Patellar bone deficiency in revision total knee arthroplasty].

    PubMed

    Kloiber, J; Goldenitsch, E; Ritschl, P

    2016-05-01

    Patellar bone deficiency in revision total knee arthroplasty (TKA) determines the surgical procedure. Different reconstructive and ablative techniques, dependent on the remaining bone stock, are described. The primary patella implant can be retained in up to 50 % of revision situations. Reasons for replacement are aseptic and septic loosening, implant failure, expanding osteolysis, maltracking of the patella and "metal-backed" prosthesis. The aim of the reconstruction is the stable fixation and proper tracking of the implant by restoring the extensor mechanism. Dependent on the extent of bone loss and the availability of a patellar rim, the following surgical procedures are recommended. When the remaining bone thickness is 10 mm or more: implantation of a polyethylene "onlay-type" patella; when it is between 6-9 mm and there is an intact patellar rim: reconstruction with a biconvex "inlay-type" patella implant, where the biconvex shape replaces the bone defect partially. When there is deficient bone stock (less than 6 mm) or no cortical patellar rim then augmenting procedures with autologous spongiosa and procedures such as "impaction bone grafting", "trabecular metal" prosthesis, where the trabecular part of the implant serves as the base for the cemented polyethylene button, "gull-wing" osteotomy, which is an adapting and configuring technique of osteotomy; and in exceptional cases patelloplasty or patellectomy are used. Regarding the importance of the patellar component in biomechanics of the joint and function of the extensor mechanism, the reconstruction of the patella should be the primary aim. Patelloplasty or patellectomy should be avoided.

  5. In vitro biomechanical comparison of equine proximal interphalangeal joint arthrodesis techniques: prototype equine spoon plate versus axially positioned dynamic compression plate and two abaxial transarticular cortical screws inserted in lag fashion.

    PubMed

    Sod, Gary A; Mitchell, Colin F; Hubert, Jeremy D; Martin, George S; Gill, Marjorie S

    2007-12-01

    To compare in vitro monotonic biomechanical properties of an equine spoon plate (ESP) with an axial 3-hole, 4.5 mm narrow dynamic compression plate (DCP) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws (DCP-TLS) inserted in lag fashion for equine proximal interphalangeal (PIP) joint arthrodesis. Paired in vitro biomechanical testing of 2 methods of stabilizing cadaveric adult equine forelimb PIP joints. Cadaveric adult equine forelimbs (n=18 pairs). For each forelimb pair, 1 PIP joint was stabilized with an ESP (8 hole, 4.5 mm) and 1 with an axial 3-hole narrow DCP (4.5 mm) using 5.5 mm cortical screws in conjunction with 2 abaxial transarticular 5.5 mm cortical screws inserted in lag fashion. Six matching pairs of constructs were tested in single cycle to failure under axial compression with load applied under displacement control at a constant rate of 5 cm/s. Six construct pairs were tested for cyclic fatigue under axial compression with cyclic load (0-7.5 kN) applied at 6 Hz; cycles to failure were recorded. Six construct pairs were tested in single cycle to failure under torsional loading applied at a constant displacement rate (0.17 radians/s) until rotation of 0.87 radians occurred. Mean values for each fixation method were compared using a paired t-test within each group with statistical significance set at P<.05. Mean yield load, yield stiffness, and failure load for ESP fixation were significantly greater (for axial compression and torsion) than for DCP-TLS fixation. Mean (+/- SD) values for the ESP and DCP-TLS fixation techniques, respectively, in single cycle to failure under axial compression were: yield load 123.9 +/- 8.96 and 28.5 +/- 3.32 kN; stiffness, 13.11 +/- 0.242 and 2.60 +/- 0.17 kN/cm; and failure load, 144.4 +/- 13.6 and 31.4 +/- 3.8 kN. In single cycle to failure under torsion, mean (+/- SD) values for ESP and DCP-TLS, respectively, were: stiffness 2,022 +/- 26.2 and 107.9 +/- 11.1 N m/rad; and failure load: 256.4 +/- 39.2 and 87.1 +/- 11.5 N m. Mean cycles to failure in axial compression of ESP fixation (622,529 +/- 65,468) was significantly greater than DCP-TLS (95,418 +/- 11,037). ESP was superior to an axial 3-hole narrow DCP with 2 abaxial transarticular screws inserted in lag fashion in resisting static overload forces and cyclic fatigue. In vitro results support further evaluation of ESP for PIP joint arthrodesis in horses. Its specific design may provide increased stability without need for external coaptation support.

  6. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    PubMed

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  7. Visual Discomfort From Flash Afterimages of Riloid Patterns.

    PubMed

    O'Hare, Louise

    2017-06-01

    Op-art-based stimuli have been shown to be uncomfortable, possibly due to a combination of fixational eye movements (microsaccades) and excessive cortical responses. Efforts have been made to measure illusory phenomena arising from these stimuli in the absence of microsaccades, but there has been no attempt thus far to decouple the effects of the cortical response from the effect of fixational eye movements. This study uses flash afterimages to stabilise the image on the retina and thus reduce the systematic effect of eye movements, in order to investigate the role of the brain in discomfort from op-art-based stimuli. There was a relationship between spatial frequency and the magnitude of the P300 response, showing a similar pattern to that of discomfort judgements, which suggests that there might be a role of discomfort and excessive neural responses independently from the effects of microsaccades.

  8. Faciotopy—A face-feature map with face-like topology in the human occipital face area

    PubMed Central

    Henriksson, Linda; Mur, Marieke; Kriegeskorte, Nikolaus

    2015-01-01

    The occipital face area (OFA) and fusiform face area (FFA) are brain regions thought to be specialized for face perception. However, their intrinsic functional organization and status as cortical areas with well-defined boundaries remains unclear. Here we test these regions for “faciotopy”, a particular hypothesis about their intrinsic functional organisation. A faciotopic area would contain a face-feature map on the cortical surface, where cortical patches represent face features and neighbouring patches represent features that are physically neighbouring in a face. The faciotopy hypothesis is motivated by the idea that face regions might develop from a retinotopic protomap and acquire their selectivity for face features through natural visual experience. Faces have a prototypical configuration of features, are usually perceived in a canonical upright orientation, and are frequently fixated in particular locations. To test the faciotopy hypothesis, we presented images of isolated face features at fixation to subjects during functional magnetic resonance imaging. The responses in V1 were best explained by low-level image properties of the stimuli. OFA, and to a lesser degree FFA, showed evidence for faciotopic organization. When a single patch of cortex was estimated for each face feature, the cortical distances between the feature patches reflected the physical distance between the features in a face. Faciotopy would be the first example, to our knowledge, of a cortical map reflecting the topology, not of a part of the organism itself (its retina in retinotopy, its body in somatotopy), but of an external object of particular perceptual significance. PMID:26235800

  9. Faciotopy-A face-feature map with face-like topology in the human occipital face area.

    PubMed

    Henriksson, Linda; Mur, Marieke; Kriegeskorte, Nikolaus

    2015-11-01

    The occipital face area (OFA) and fusiform face area (FFA) are brain regions thought to be specialized for face perception. However, their intrinsic functional organization and status as cortical areas with well-defined boundaries remains unclear. Here we test these regions for "faciotopy", a particular hypothesis about their intrinsic functional organisation. A faciotopic area would contain a face-feature map on the cortical surface, where cortical patches represent face features and neighbouring patches represent features that are physically neighbouring in a face. The faciotopy hypothesis is motivated by the idea that face regions might develop from a retinotopic protomap and acquire their selectivity for face features through natural visual experience. Faces have a prototypical configuration of features, are usually perceived in a canonical upright orientation, and are frequently fixated in particular locations. To test the faciotopy hypothesis, we presented images of isolated face features at fixation to subjects during functional magnetic resonance imaging. The responses in V1 were best explained by low-level image properties of the stimuli. OFA, and to a lesser degree FFA, showed evidence for faciotopic organization. When a single patch of cortex was estimated for each face feature, the cortical distances between the feature patches reflected the physical distance between the features in a face. Faciotopy would be the first example, to our knowledge, of a cortical map reflecting the topology, not of a part of the organism itself (its retina in retinotopy, its body in somatotopy), but of an external object of particular perceptual significance. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  10. Virtual stress testing of fracture stability in soldiers with severely comminuted tibial fractures.

    PubMed

    Petfield, Joseph L; Hayeck, Garry T; Kopperdahl, David L; Nesti, Leon J; Keaveny, Tony M; Hsu, Joseph R

    2017-04-01

    Virtual stress testing (VST) provides a non-invasive estimate of the strength of a healing bone through a biomechanical analysis of a patient's computed tomography (CT) scan. We asked whether VST could improve management of patients who had a tibia fracture treated with external fixation. In a retrospective case-control study of 65 soldier-patients who had tibia fractures treated with an external fixator, we performed VST utilizing CT scans acquired prior to fixator removal. The strength of the healing bone and the amount of tissue damage after application of an overload were computed for various virtual loading cases. Logistic regression identified computed outcomes with the strongest association to clinical events related to nonunion within 2 months after fixator removal. Clinical events (n = 9) were associated with a low tibial strength for compression loading (p < 0.05, AUC = 0.74) or a low proportion of failed cortical bone tissue for torsional loading (p < 0.005, AUC = 0.84). Using post-hoc thresholds of a compressive strength of four times body-weight and a proportional of failed cortical bone tissue of 5%, the test identified all nine patients who failed clinically (100% sensitivity; 40.9% positive predictive value) and over three fourths of those (43 of 56) who progressed to successful healing (76.8% specificity; 100% negative predictive value). In this study, VST identified all patients who progressed to full, uneventful union after fixator removal; thus, we conclude that this new test has the potential to provide a quantitative, objective means of identifying tibia-fracture patients who can safely resume weight bearing. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:805-811, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Pseudo-Fovea Formation After Gene Therapy for RPE65-LCA

    PubMed Central

    Cideciyan, Artur V.; Aguirre, Geoffrey K.; Jacobson, Samuel G.; Butt, Omar H.; Schwartz, Sharon B.; Swider, Malgorzata; Roman, Alejandro J.; Sadigh, Sam; Hauswirth, William W.

    2015-01-01

    Purpose. The purpose of this study was to evaluate fixation location and oculomotor characteristics of 15 patients with Leber congenital amaurosis (LCA) caused by RPE65 mutations (RPE65-LCA) who underwent retinal gene therapy. Methods. Eye movements were quantified under infrared imaging of the retina while the subject fixated on a stationary target. In a subset of patients, letter recognition under retinal imaging was performed. Cortical responses to visual stimulation were measured using functional magnetic resonance imaging (fMRI) in two patients before and after therapy. Results. All patients were able to fixate on a 1° diameter visible target in the dark. The preferred retinal locus of fixation was either at the anatomical fovea or at an extrafoveal locus. There were a wide range of oculomotor abnormalities. Natural history showed little change in oculomotor abnormalities if target illuminance was increased to maintain target visibility as the disease progressed. Eleven of 15 study eyes treated with gene therapy showed no differences from baseline fixation locations or instability over an average of follow-up of 3.5 years. Four of 15 eyes developed new pseudo-foveas in the treated retinal regions 9 to 12 months after therapy that persisted for up to 6 years; patients used their pseudo-foveas for letter identification. fMRI studies demonstrated that preservation of light sensitivity was restricted to the cortical projection zone of the pseudo-foveas. Conclusions. The slow emergence of pseudo-foveas many months after the initial increases in light sensitivity points to a substantial plasticity of the adult visual system and a complex interaction between it and the progression of underlying retinal disease. The visual significance of pseudo-foveas suggests careful consideration of treatment zones for future gene therapy trials. (ClinicalTrials.gov number, NCT00481546.) PMID:25537204

  12. Cortical bone viscoelasticity and fixation strength of press-fit femoral stems: an in-vitro model.

    PubMed

    Norman, T L; Ackerman, E S; Smith, T S; Gruen, T A; Yates, A J; Blaha, J D; Kish, V L

    2006-02-01

    Cementless total hip femoral components rely on press-fit for initial stability and bone healing and remodeling for secondary fixation. However, the determinants of satisfactory press-fit are not well understood. In previous studies, human cortical bone loaded circumferentially to simulate press-fit exhibited viscoelastic, or time dependent, behavior. The effect of bone viscoelastic behavior on the initial stability of press-fit stems is not known. Therefore, in the current study, push-out loads of cylindrical stems press-fit into reamed cadaver diaphyseal femoral specimens were measured immediately after assembly and 24 h with stem-bone diametral interference and stem surface treatment as independent variables. It was hypothesized that stem-bone interference would result in a viscoelastic response of bone that would decrease push-out load thereby impairing initial press-fit stability. Results showed that push-out load significantly decreased over a 24 h period due to bone viscoelasticity. It was also found that high and low push-out loads occurred at relatively small amounts of stem-bone interference, but a relationship between stem-bone interference and push-out load could not be determined due to variability among specimens. On the basis of this model, it was concluded that press-fit fixation can occur at relatively low levels of diametral interference and that stem-bone interference elicits viscoelastic response that reduces stem stability over time. From a clinical perspective, these results suggest that there could be large variations in initial press-fit fixation among patients.

  13. A comparison of bicortical and intramedullary screw fixations of Jones' fractures.

    PubMed

    Husain, Zeeshan S; DeFronzo, Donna J

    2002-01-01

    Two different fixations for treatment of Jones' fracture were tested in bone models and cadaveric specimens to determine the differences in the stability of the constructs. A bicortical 3.5-mm cannulated cortical screw and an intramedullary 4.0-mm partially threaded cancellous screw were tested using physiologic loads with an Instron 8500 servohydraulic tensiometer (Instron Corporation, Canton, MA). In bone models, the bicortical construct (n = 5, 87+/-23 N) showed superior fixation strength (p = .0009) when compared to the intramedullary screw fixation (n = 5, 25+/-13 N). Cadaveric testing showed similar statistical significance (p = .0124) with the bicortical construct (n = 5, 152+/-71 N) having greater load resistance than the intramedullary screw fixation (n = 4, 29+/-20 N). In bone models, the bicortical constructs (23+/-9 N/mm) showed over twice the elastic modulus than the intramedullary screw fixations (9+/-4 N/mm) with statistical significance (p = .0115). The elastic modulus in the cadaveric group showed a similar pattern between the bicortical (19+/-17 N/mm) and intramedullary (9+/-6 N/mm) screw constructs. Analysis of the bicortical screw failure patterns revealed that screw orientation had a critical impact on fixation stability. The more distal the exit site of the bicortical screw was from the fracture site, the greater the load needed to displace the fixation.

  14. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    PubMed

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p < 0.05 and p > 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation for 2-level DS could be less invasive and result in improvement of clinical symptoms equal to those of 2-level PLIF using traditional PS fixation. The incidence of symptomatic ASD and the rate of bony union were lower in the CBT group than in the PS group, although these differences were not significant.

  15. Index metacarpal fracture after tightrope suspension following trapeziectomy: case report.

    PubMed

    Khalid, Mohammed; Jones, Matthew L

    2012-03-01

    Trapeziectomy, by itself or combined with ligament reconstruction/interposition arthroplasty, is commonly performed for advanced trapezial-metacarpal arthritis. Several methods and materials, both autogenous and artificial, are commonly used for ligament reconstruction and interposition arthroplasty. Harvesting autologous tendons adds to operative time and could increase potential surgical complications. Using an artificial material would, in theory, avoid some of these problems. However, this approach is not without its problems. We present a case of index metacarpal fracture after using the Arthrex Mini TightRope (Arthrex, Naples, FL) suture button fixation of the thumb and index metacarpals after complete trapeziectomy. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  16. Complications after arthroscopic coracoclavicular reconstruction using a single adjustable-loop-length suspensory fixation device in acute acromioclavicular joint dislocation.

    PubMed

    Shin, Sang-Jin; Kim, Nam-Ki

    2015-05-01

    The purpose of this study was to evaluate clinical and radiological outcomes after arthroscopically assisted coracoclavicular (CC) fixation using a single adjustable-loop-length suspensory fixation device for acute acromioclavicular dislocation and to report intraoperative and postoperative complications. Eighteen consecutive patients with acute acromioclavicular dislocation underwent arthroscopically assisted CC fixation using a single TightRope (Arthrex, Naples, FL). Using the Rockwood classification, 3 patients had grade III dislocations, one patient had a grade IV dislocation, and 14 patients had grade V dislocations. The preoperative CC distance of the injured shoulder was 16.1 ± 2.7 mm (range, 11.2 to 21.0 mm), and it increased by 99% ± 36% (range, 17% to 153%) on average compared with the contralateral shoulder. The average CC distance was 10.5 ± 2.5 mm (range, 7.7 to 15.5 mm), and it increased by 30% ± 30% (range, -9.4% to 90%) at the final follow-up. Compared with immediate postoperative radiographs, the CC distance was maintained in 12 patients, increased between 50% and 100% in 4 patients, and increased more than 100% in 2 patients at final follow-up. However, there was no statistical difference in Constant scores between 6 patients with reduction loss (95.6 ± 4.5) and 12 patients with reduction maintenance (98.4 ± 2.5; P = .17). Perioperative complications occurred in 8 patients, including one case of acromioclavicular arthritis, one case of delayed distal clavicular fracture at the clavicular hole of the device, 3 cases of clavicular or coracoid button failures, and 3 cases of clavicular bony erosion. Satisfactory clinical outcomes were obtained after CC fixation using the single adjustable-loop-length suspensory fixation device for acute acromioclavicular joint dislocation. However, CC fixation failure of greater than 50% of the unaffected side in radiological examinations occurred in 33% of the patients within 3 months after the operation. Additionally, 8 patients (44%) had complications associated with the adjustable-loop-length suspensory fixation device and surgical technical problems. Despite acceptable shoulder function restoration, adequate care should be exercised in surgical treatment of acute acromioclavicular dislocation with a single adjustable-loop-length suspensory fixation device for optimal radiological outcomes. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  17. Acid-resistant calcium silicate-based composite implants with high-strength as load-bearing bone graft substitutes and fracture fixation devices.

    PubMed

    Wei, Chung-Kai; Ding, Shinn-Jyh

    2016-09-01

    To achieve the excellent mechanical properties of biodegradable materials used for cortical bone graft substitutes and fracture fixation devices remains a challenge. To this end, the biomimetic calcium silicate/gelatin/chitosan oligosaccharide composite implants were developed, with an aim of achieving high strength, controlled degradation, and superior osteogenic activity. The work focused on the effect of gelatin on mechanical properties of the composites under four different kinds of mechanical stresses including compression, tensile, bending, and impact. The evaluation of in vitro degradability and fatigue at two simulated body fluid (SBF) of pH 7.4 and 5.0 was also performed, in which the pH 5.0 condition simulated clinical conditions caused by bacterial induced local metabolic acidosis or tissue inflammation. In addition, human mesenchymal stem cells (hMSCs) were sued to examine osteogenic activity. Experimental results showed that the appropriate amount of gelatin positively contributed to failure enhancement in compressive and impact modes. The 10wt% gelatin-containing composite exhibits the maximum value of the compressive strength (166.1MPa), which is within the reported compressive strength for cortical bone. The stability of the bone implants was apparently affected by the in vitro fatigue, but not by the initial pH environments (7.4 or 5.0). The gelatin not only greatly enhanced the degradation of the composite when soaked in the dynamic SBF solution, but effectively promoted attachment, proliferation, differentiation, and formation of mineralization of hMSCs. The 10wt%-gelatin composite with high initial strength may be a potential implant candidate for cortical bone repair and fracture fixation applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Gap formation following primary repair of the anterior cruciate ligament: A biomechanical evaluation.

    PubMed

    van der List, Jelle P; DiFelice, Gregory S

    2017-03-01

    Historically, inconsistent and unpredictable results of open primary anterior cruciate ligament (ACL) repair were reported. Recently, however, good results of arthroscopic primary ACL repair of proximal tears have been reported. Purpose of this study was to assess the direct postoperative gap formation and maximum failure load following simulated knee motion after primary ACL repair. Six matched-paired human cadaveric knees (mean age: 52years, range: 48 to 56years) were used. After primary proximal ACL repair with either suture button fixation or suture anchor fixation, knees were cycled five, 50 and 100 times with a simulated active quadriceps force. Gap formation between the femoral wall and ligament was measured using a digital caliper and maximum failure load was tested. Gap formation after five, 50 and 100cycles of the knee were 0.30mm (±0.23), 0.75mm (±0.55) and 0.97mm (±0.70), respectively, with no significant differences between both fixation techniques. The overall maximum failure load was 243N (±143) with no difference between both techniques. Most common failure mode was slipping of suture from the fixation. Following proximal ACL repair, gap formation of approximately one millimeter was measured after repetitious knee cycling with mean maximum failure load of 243N. These findings are likely to be sufficient for careful early active range of motion (ROM) when extrapolating from other available studies. Future studies with second-look arthroscopy are necessary to assess the gap formation and healing in patients treated with primary repair. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Cortical functional anatomy of voluntary saccades in Parkinson disease.

    PubMed

    Rieger, Jochem W; Kim, Aleander; Argyelan, Miklos; Farber, Mark; Glazman, Sofya; Liebeskind, Marc; Meyer, Thomas; Bodis-Wollner, Ivan

    2008-10-01

    In Parkinson Disease (PD) several aspects of saccades are affected. The saccade-generating brainstem neurons are spared, however, the signals they receive may be flawed. In particular voluntary saccades suffer, but the functional anatomy of the impairment of saccade-related cortical control is unknown. We measured blood-oxygenation-level-dependent (BOLD) activation with functional Magnetic Resonance Imaging (fMRI) while healthy participants and patients with PD performed horizontal voluntary saccades between peripheral visual targets or fixated centrally. We compared saccade-related BOLD-activity vs. fixation in patients with PD and in healthy controls and correlated perisaccadic BOLD-activity in PD patients with saccade kinetics (multistep saccades). Saccade related BOLD-activation was found in both PD and healthy participants in the superior parietal cortex (PEF) and the occipital cortex. Our results suggest remarkable hypoactivity of the frontal and supplementary eye fields (FEF and SEF) in PD patients. On the other hand, PD patients showed a statistically more reliable BOLD modulation than healthy participants in the posterior cingulate gyrus, the parahippocampal gyrus, inferior parietal lobule, precuneus and in the middle temporal gyrus. Given abnormal frontal and normal PEF responses, our results suggest that in PD a frontal cortical circuitry, known to be associated with saccade planning, selection, and predicting a metric error of the saccade, is deficient.

  20. Neural network models for spatial data mining, map production, and cortical direction selectivity

    NASA Astrophysics Data System (ADS)

    Parsons, Olga

    A family of ARTMAP neural networks for incremental supervised learning has been developed over the last decade. The Sensor Exploitation Group of MIT Lincoln Laboratory (LL) has incorporated an early version of this network as the recognition engine of a hierarchical system for fusion and data mining of multiple registered geospatial images. The LL system has been successfully fielded, but it is limited to target vs. non-target identifications and does not produce whole maps. This dissertation expands the capabilities of the LL system so that it learns to identify arbitrarily many target classes at once and can thus produce a whole map. This new spatial data mining system is designed particularly to cope with the highly skewed class distributions of typical mapping problems. Specification of a consistent procedure and a benchmark testbed has permitted the evaluation of candidate recognition networks as well as pre- and post-processing and feature extraction options. The resulting default ARTMAP network and mapping methodology set a standard for a variety of related mapping problems and application domains. The second part of the dissertation investigates the development of cortical direction selectivity. The possible role of visual experience and oculomotor behavior in the maturation of cells in the primary visual cortex is studied. The responses of neurons in the thalamus and cortex of the cat are modeled when natural scenes are scanned by several types of eye movements. Inspired by the Hebbian-like synaptic plasticity, which is based upon correlations between cell activations, the second-order statistical structure of thalamo-cortical activity is examined. In the simulations, patterns of neural activity that lead to a correct refinement of cell responses are observed during visual fixation, when small ocular movements occur, but are not observed in the presence of large saccades. Simulations also replicate experiments in which kittens are reared under stroboscopic illumination. The abnormal fixational eye movements of these cats may account for the puzzling finding of a specific loss of cortical direction selectivity but preservation of orientation selectivity. This work indicates that the oculomotor behavior of visual fixation may play an important role in the refinement of cell response selectivity.

  1. Oscillatory cortical network involved in auditory verbal hallucinations in schizophrenia.

    PubMed

    van Lutterveld, Remko; Hillebrand, Arjan; Diederen, Kelly M J; Daalman, Kirstin; Kahn, René S; Stam, Cornelis J; Sommer, Iris E C

    2012-01-01

    Auditory verbal hallucinations (AVH), a prominent symptom of schizophrenia, are often highly distressing for patients. Better understanding of the pathogenesis of hallucinations could increase therapeutic options. Magnetoencephalography (MEG) provides direct measures of neuronal activity and has an excellent temporal resolution, offering a unique opportunity to study AVH pathophysiology. Twelve patients (10 paranoid schizophrenia, 2 psychosis not otherwise specified) indicated the presence of AVH by button-press while lying in a MEG scanner. As a control condition, patients performed a self-paced button-press task. AVH-state and non-AVH state were contrasted in a region-of-interest (ROI) approach. In addition, the two seconds before AVH onset were contrasted with the two seconds after AVH onset to elucidate a possible triggering mechanism. AVH correlated with a decrease in beta-band power in the left temporal cortex. A decrease in alpha-band power was observed in the right inferior frontal gyrus. AVH onset was related to a decrease in theta-band power in the right hippocampus. These results suggest that AVH are triggered by a short aberration in the theta band in a memory-related structure, followed by activity in language areas accompanying the experience of AVH itself.

  2. Objective visual assessment of antiangiogenic treatment for wet age-related macular degeneration.

    PubMed

    Baseler, Heidi A; Gouws, André; Crossland, Michael D; Leung, Carmen; Tufail, Adnan; Rubin, Gary S; Morland, Antony B

    2011-10-01

    To assess cortical responses in patients undergoing antiangiogenic treatment for wet age-related macular degeneration (AMD) using functional magnetic resonance imaging (fMRI) as an objective, fixation-independent measure of topographic visual function. A patient with bilateral neovascular AMD was scanned using fMRI before and at regular intervals while undergoing treatment with intravitreal antiangiogenic injections (ranibizumab). Blood oxygenation level-dependent signals were measured in the brain while the patient viewed a stimulus consisting of a full-field flickering (6 Hz) white light alternating with a uniform gray background (18 s on and 18 s off). Topographic distribution and magnitude of activation in visual cortex were compared longitudinally throughout the treatment period (<1 year) and with control patients not currently undergoing treatment. Clinical behavioral tests were also administered, including visual acuity, microperimetry, and reading skills. The area of visual cortex activated increased significantly after the first treatment to include more posterior cortex that normally receives inputs from lesioned parts of the retina. Subsequent treatments yielded no significant further increase in activation area. Behavioral measures all generally showed an improvement with treatment but did not always parallel one another. The untreated control patient showed a consistent lack of significant response in the cortex representing retinal lesions. Retinal treatments may not only improve vision but also result in a concomitant improvement in fixation stability. Current clinical behavioral measures (e.g., acuity and perimetry) are largely dependent on fixation stability and therefore cannot separate improvements of visual function from fixation improvements. fMRI, which provides an objective and sensitive measure of visual function independent of fixation, reveals a significant increase in visual cortical responses in patients with wet AMD after treatment with antiangiogenic injections. Despite recent evidence that visual cortex degenerates subsequent to retinal lesions, our results indicate that it can remain responsive as its inputs are restored.

  3. [Three-dimensional Finite Element Analysis to T-shaped Fracture of Pelvis in Sitting Position].

    PubMed

    Fan, Yanping; Lei, Jianyin; Liu, Haibo; Li, Zhiqiang; Cai, Xianhua; Chen, Weiyi

    2015-10-01

    We developed a three-dimensional finite element model of the pelvis. According to Letournel methods, we established a pelvis model of T-shaped fracture with its three different fixation systems, i. e. double column reconstruction plates, anterior column plate combined with posterior column screws and anterior column plate combined with quadrilateral area screws. It was found that the pelvic model was effective and could be used to simulate the mechanical behavior of the pelvis. Three fixation systems had great therapeutic effect on the T-shaped fracture. All fixation systems could increase the stiffness of the model, decrease the stress concentration level and decrease the displacement difference along the fracture line. The quadrilateral area screws, which were drilled into cortical bone, could generate beneficial effect on the T-type fracture. Therefore, the third fixation system mentioned above (i. e. the anterior column plate combined with quadrilateral area screws) has the best biomechanical stability to the T-type fracture.

  4. Pullout strength of monocortical and bicortical screws in metaphyseal and diaphyseal regions of the canine humerus.

    PubMed

    Vaughn, Denty Paul; Syrcle, Jason Alan; Ball, John E; Elder, Steven H; Gambino, Jennifer Michele; Griffin, Russell L; McLaughlin, Ronald M

    2016-11-23

    Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short monocortical screws in metaphyseal bone may be contraindicated. Objectives of this study were to evaluate axial pullout strength of two different lengths of monocortical screws placed in various regions of the canine humerus compared to bicortical screws, and to derive cortical thickness and bone density values for those regions using quantitative computed tomography analysis (QCT). The QCT analysis was performed on 36 cadaveric canine humeri for six regions of interest (ROI). A bicortical, short monocortical, or 50% transcortical 3.5 mm screw was implanted in each ROI and axial pullout testing was performed. Bicortical screws were stronger than monocortical screws in all ROI except the lateral epicondylar crest. Short monocortical metaphyseal screws were weaker than those placed in other regions. The 50% transcortical screws were stronger than the short monocortical screws in the condyle. A linear relationship between screw length and pullout strength was observed. Cortical thickness and bone density measurements were obtained from multiple regions of the canine humerus using QCT. Use of short monocortical screws may contribute to failure of locking plate fixation of humeral fractures, especially when placed in the condyle. When bicortical screw placement is not possible, maximizing monocortical screw length may optimize fixation stability for distal humeral fractures.

  5. Improved Tensile Adhesion Specimens for High Strength Epoxy Systems in Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Haddock, M. Reed; McLennan, Michael L.

    2000-01-01

    An improved tensile adhesion button has been designed and tested that results in higher measured tensile adhesion strength while providing increased capability for testing high strength epoxy adhesive systems. The best attributes of two well-established tensile button designs were combined and refined into an optimized tensile button. The most significant design change to the tensile button was to improve alignment of the bonded tensile button specimens during tensile testing by changing the interface between the tensile button and the tensile test machine. The established or old button design uses a test fixture that pulls from a grooved annulus or anvil head while the new button design pulls from a threaded hole in the centerline of the button. Finite element (FE) analysis showed that asymmetric loading of the established anvil head tensile button significantly increases the stress concentration in the adhesive, causing failure at lower tensile test loads. The new tensile button was designed to eliminate asymmetric loading and eliminate misalignment sensitivity. Enhanced alignment resulted in improved tensile adhesion strength measurement up to 13.8 MPa (2000psi) over the established button design. Another design change increased the capability of the button by increasing the threaded hole diameter allowing it to test high strength epoxy systems up to 85 MPa(less than 12,000 psi). The improved tensile button can be used in button- to-button or button-to-panel configurations.

  6. Low-level and high-level modulations of fixational saccades and high frequency oscillatory brain activity in a visual object classification task

    PubMed Central

    Kosilo, Maciej; Wuerger, Sophie M.; Craddock, Matt; Jennings, Ben J.; Hunt, Amelia R.; Martinovic, Jasna

    2013-01-01

    Until recently induced gamma-band activity (GBA) was considered a neural marker of cortical object representation. However, induced GBA in the electroencephalogram (EEG) is susceptible to artifacts caused by miniature fixational saccades. Recent studies have demonstrated that fixational saccades also reflect high-level representational processes. Do high-level as opposed to low-level factors influence fixational saccades? What is the effect of these factors on artifact-free GBA? To investigate this, we conducted separate eye tracking and EEG experiments using identical designs. Participants classified line drawings as objects or non-objects. To introduce low-level differences, contours were defined along different directions in cardinal color space: S-cone-isolating, intermediate isoluminant, or a full-color stimulus, the latter containing an additional achromatic component. Prior to the classification task, object discrimination thresholds were measured and stimuli were scaled to matching suprathreshold levels for each participant. In both experiments, behavioral performance was best for full-color stimuli and worst for S-cone isolating stimuli. Saccade rates 200–700 ms after stimulus onset were modulated independently by low and high-level factors, being higher for full-color stimuli than for S-cone isolating stimuli and higher for objects. Low-amplitude evoked GBA and total GBA were observed in very few conditions, showing that paradigms with isoluminant stimuli may not be ideal for eliciting such responses. We conclude that cortical loops involved in the processing of objects are preferentially excited by stimuli that contain achromatic information. Their activation can lead to relatively early exploratory eye movements even for foveally-presented stimuli. PMID:24391611

  7. Finite Element Simulation and Additive Manufacturing of Stiffness-Matched NiTi Fixation Hardware for Mandibular Reconstruction Surgery

    PubMed Central

    Jahadakbar, Ahmadreza; Shayesteh Moghaddam, Narges; Amerinatanzi, Amirhesam; Dean, David; Karaca, Haluk E.; Elahinia, Mohammad

    2016-01-01

    Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, we present a study of mandibular reconstruction that uses a dry cadaver mandible to validate our geometric and biomechanical design and fabrication (i.e., 3D printing) of NiTi skeletal fixation hardware. Based on the reference-dried mandible, we have developed a Finite Element model to evaluate the performance of the proposed fixation. Our results show a closer-to-normal stress distribution and an enhanced contact pressure at the bone graft interface than would be in the case with Ti-6Al-4V off-the-shelf fixation hardware. The porous fixation plates used in this study were fabricated by selective laser melting. PMID:28952598

  8. Finite Element Simulation and Additive Manufacturing of Stiffness-Matched NiTi Fixation Hardware for Mandibular Reconstruction Surgery.

    PubMed

    Jahadakbar, Ahmadreza; Shayesteh Moghaddam, Narges; Amerinatanzi, Amirhesam; Dean, David; Karaca, Haluk E; Elahinia, Mohammad

    2016-12-19

    Process parameters and post-processing heat treatment techniques have been developed to produce both shape memory and superelastic NiTi using Additive Manufacturing. By introducing engineered porosity, the stiffness of NiTi can be tuned to the level closely matching cortical bone. Using additively manufactured porous superelastic NiTi, we have proposed the use of patient-specific, stiffness-matched fixation hardware, for mandible skeletal reconstructive surgery. Currently, Ti-6Al-4V is the most commonly used material for skeletal fixation devices. Although this material offers more than sufficient strength for immobilization during the bone healing process, the high stiffness of Ti-6Al-4V implants can cause stress shielding. In this paper, we present a study of mandibular reconstruction that uses a dry cadaver mandible to validate our geometric and biomechanical design and fabrication (i.e., 3D printing) of NiTi skeletal fixation hardware. Based on the reference-dried mandible, we have developed a Finite Element model to evaluate the performance of the proposed fixation. Our results show a closer-to-normal stress distribution and an enhanced contact pressure at the bone graft interface than would be in the case with Ti-6Al-4V off-the-shelf fixation hardware. The porous fixation plates used in this study were fabricated by selective laser melting.

  9. Biomechanics of Far Cortical Locking

    PubMed Central

    Bottlang, Michael; Feist, Florian

    2011-01-01

    The development of FCL was motivated by a conundrum: locked plating constructs provide inherently rigid stabilization, yet they should facilitate biological fixation and secondary bone healing that relies on flexible fixation to stimulate callus formation. Recent studies have confirmed that the high stiffness of standard locked plating constructs can suppress interfragmentary motion to a level that is insufficient to reliably promote secondary fracture healing by callus formation. Furthermore, rigid locking screws cause an uneven stress distribution that may lead to stress fracture at the end screw and stress shielding under the plate. This review summarizes four key features of FCL constructs that have shown to enhance fixation and fracture healing: Flexible fixation, load distribution, progressive stiffening, and parallel interfragmentary motion. Specifically, flexible fixation provided by FCL reduces the stiffness of a locked plating construct by 80–88% to actively promote callus proliferation similar to an external fixator. Load distribution is evenly shared between FCL screws to mitigate stress risers at the end screw. Progressive stiffening occurs by near cortex support of FCL screws and provides additional support under elevated loading. Finally, parallel interfragmentary motion by s-shaped flexion of FCL screws has shown to induce symmetric callus formation. In combination, these features of FCL constructs have shown to induce more callus and to yield significantly stronger and more consistent healing compared to standard locked plating constructs. As such, FCL constructs function as true internal fixators by replicating the biomechanical behavior and biological healing response of external fixators. PMID:21248556

  10. Development of a Three-Dimensional (3D) Printed Biodegradable Cage to Convert Morselized Corticocancellous Bone Chips into a Structured Cortical Bone Graft.

    PubMed

    Chou, Ying-Chao; Lee, Demei; Chang, Tzu-Min; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung; Ueng, Steve Wen-Neng

    2016-04-20

    This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire) fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft.

  11. Development of a Three-Dimensional (3D) Printed Biodegradable Cage to Convert Morselized Corticocancellous Bone Chips into a Structured Cortical Bone Graft

    PubMed Central

    Chou, Ying-Chao; Lee, Demei; Chang, Tzu-Min; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung; Ueng, Steve Wen-Neng

    2016-01-01

    This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire) fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft. PMID:27104525

  12. Mechanical evaluation of the SLM fabricated, stiffness-matched, mandibular bone fixation plates

    NASA Astrophysics Data System (ADS)

    Jahadakbar, Ahmadreza; Shayesteh Moghaddam, Narges; Amerinatanzi, Amirhesam; Dean, David; Elahinia, Mohammad

    2018-03-01

    The standard of the care for the treatment of mandibular segmental defects is the use of Ti-6Al-4V bone fixation plates and screws to immobilize the grafted bone and the host mandible. While Ti-6Al-4V bone fixation plates provide strong immobilization during the healing period, they may disturb the stress distribution in the repaired mandible. The highly stiff Ti-6Al-4V fixation carries a great portion of the load which was previously borne by the mandible, and stress shielding may occur on the surrounding cortical bone. Based on the bone remodeling theory, stress shielding causes bone resorption in the effected region and may eventually lead to the failure of the surgical reconstruction. To address this issue, we have developed a new generation of the patient-specific, porous NiTi bone fixation plates which benefit from stiffness-matching of the adjacent bone. Using the CT scan data of the patient's defective mandible, the geometry for the required bone fixation plates is designed and the stiffness of the surrounding regions is measured. By introducing specific level and type of porosity to the bone fixation plate, its stiffness can be tuned. Finite Element simulations has verified the reduced level of stress shielding on the reconstructed mandible, in case of using the proposed bone fixation plates. Selective Lase Sintering has been used for fabrication of the porous NiTi bone fixation plates with six different levels of stiffness. Finite element simulations, and mechanical tests have been done to verify the performance of the fabricated parts resulting from our design and fabrication method.

  13. Development of the eye-movement response in the trainee radiologist

    NASA Astrophysics Data System (ADS)

    Wooding, David S.; Roberts, Geraint M.; Phillips-Hughes, Jane

    1999-05-01

    In order to explore the initial response of the visual system to radiological images in groups of individuals with increasing degrees of radiological training and experience, the locations of fixations made during visual inspection of digitized chest radiographs were examined for 4 groups of observers: 10 experienced radiologists, 9 first-year 'novice' radiologists, 11 'trainee' radiologists in the second and third years of their training, and 7 native controls. Each observer viewed 12 digitized chest radiographs (6 normal and 6 showing some abnormality) in a VDU for 8s each. Eye movements were recorded throughout and observers indicated via a button box whether they thought the radiograph to be normal or abnormal. A least squares index was utilized in order to quantify the similarity in fixation location between pairs of eye movement traces over the first 1.5 and 3 seconds of an inspection. The similarities thus produced were then averaged to give intra- and inter-group similarities in fixation location. The fixation locations of experienced radiologists were found to be highly similar as a group, as were those of the novices. While the fixation locations of controls showed less similarity, it was the fixations of trainees which were the least similar (i.e. showed the most variability) within their group. The fixation locations of novices showed a greater similarity to those of radiologists than those of controls, and a decreased similarity to those of controls than those of the controls themselves. However, rather than showing that the fixation locations of individuals become increasing similar to those of radiologists as training progresses, the data show that the more variable fixation locations of trainees are the least similar to those of radiologists than those of any of the groups, even the controls. Control observers examine every day images in a similar way and this is also true of radiological images. Experienced radiologists view radiological images in a similar way to each other, but their training has resulted in differences between them and controls. In becoming experienced radiologists, it appears that trainees may move through a developmental phase characterized by more idiosyncratic eye movements; their eye movements becoming less similar to controls or experienced radiologists than they were. With experience the eye movements of trainee radiologists may become more similar to both groups, but the transition of the trainee from novice to experienced radiologist is not a simple one: the change involves a period of some disorder.

  14. [Stress analysis of femoral stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer].

    PubMed

    Oomori, H; Imura, S; Gesso, H

    1992-04-01

    To develop stem design achieving primary fixation of stems and effective load transfer to the femur, we studied stress analysis of stems in cementless total hip arthroplasty by two-dimensional finite element method using boundary friction layer in stem-bone interface. The results of analyses of stem-bone interface stresses and von Mises stresses at the cortical bones indicated that ideal stem design features would be as follows: 1) Sufficient length, with the distal end extending beyond the isthmus region. 2) Maximum possible width, to contact the cortical bones in the isthmus region. 3) No collars but a lateral shoulder at the proximal portion. 4) A distal tip, to contact the cortical bones at the distal portion.

  15. Toward FRP-Based Brain-Machine Interfaces—Single-Trial Classification of Fixation-Related Potentials

    PubMed Central

    Finke, Andrea; Essig, Kai; Marchioro, Giuseppe; Ritter, Helge

    2016-01-01

    The co-registration of eye tracking and electroencephalography provides a holistic measure of ongoing cognitive processes. Recently, fixation-related potentials have been introduced to quantify the neural activity in such bi-modal recordings. Fixation-related potentials are time-locked to fixation onsets, just like event-related potentials are locked to stimulus onsets. Compared to existing electroencephalography-based brain-machine interfaces that depend on visual stimuli, fixation-related potentials have the advantages that they can be used in free, unconstrained viewing conditions and can also be classified on a single-trial level. Thus, fixation-related potentials have the potential to allow for conceptually different brain-machine interfaces that directly interpret cortical activity related to the visual processing of specific objects. However, existing research has investigated fixation-related potentials only with very restricted and highly unnatural stimuli in simple search tasks while participant’s body movements were restricted. We present a study where we relieved many of these restrictions while retaining some control by using a gaze-contingent visual search task. In our study, participants had to find a target object out of 12 complex and everyday objects presented on a screen while the electrical activity of the brain and eye movements were recorded simultaneously. Our results show that our proposed method for the classification of fixation-related potentials can clearly discriminate between fixations on relevant, non-relevant and background areas. Furthermore, we show that our classification approach generalizes not only to different test sets from the same participant, but also across participants. These results promise to open novel avenues for exploiting fixation-related potentials in electroencephalography-based brain-machine interfaces and thus providing a novel means for intuitive human-machine interaction. PMID:26812487

  16. Effect of screw position on load transfer in lumbar pedicle screws: A non-idealized finite element analysis

    PubMed Central

    Newcomb, Anna G. U. S.; Baek, Seungwon; Kelly, Brian P.; Crawford, Neil R.

    2016-01-01

    Angled screw insertion has been advocated to enhance fixation strength during posterior spine fixation. Stresses on a pedicle screw and surrounding vertebral bone with different screw angles were studied by finite element analysis during simulated multidirectional loading. Correlations between screw-specific vertebral geometric parameters and stresses were studied. Angulations in both the sagittal and axial planes affected stresses on the cortical and cancellous bones and the screw. Pedicle screws pointing laterally (vs. straight or medially) in the axial plane during superior screw angulation may be advantageous in terms of reducing the risk of both screw loosening and screw breakage. PMID:27454197

  17. The influence of visual training on predicting complex action sequences.

    PubMed

    Cross, Emily S; Stadler, Waltraud; Parkinson, Jim; Schütz-Bosbach, Simone; Prinz, Wolfgang

    2013-02-01

    Linking observed and executable actions appears to be achieved by an action observation network (AON), comprising parietal, premotor, and occipitotemporal cortical regions of the human brain. AON engagement during action observation is thought to aid in effortless, efficient prediction of ongoing movements to support action understanding. Here, we investigate how the AON responds when observing and predicting actions we cannot readily reproduce before and after visual training. During pre- and posttraining neuroimaging sessions, participants watched gymnasts and wind-up toys moving behind an occluder and pressed a button when they expected each agent to reappear. Between scanning sessions, participants visually trained to predict when a subset of stimuli would reappear. Posttraining scanning revealed activation of inferior parietal, superior temporal, and cerebellar cortices when predicting occluded actions compared to perceiving them. Greater activity emerged when predicting untrained compared to trained sequences in occipitotemporal cortices and to a lesser degree, premotor cortices. The occipitotemporal responses when predicting untrained agents showed further specialization, with greater responses within body-processing regions when predicting gymnasts' movements and in object-selective cortex when predicting toys' movements. The results suggest that (1) select portions of the AON are recruited to predict the complex movements not easily mapped onto the observer's body and (2) greater recruitment of these AON regions supports prediction of less familiar sequences. We suggest that the findings inform both the premotor model of action prediction and the predictive coding account of AON function. Copyright © 2011 Wiley Periodicals, Inc.

  18. Fixation of revision implants is improved by new surgical technique to crack the sclerotic endosteal rim.

    PubMed

    Kold, S; Soballe, K; Mouzin, O; Chen, Xiangmei; Toft, M; Bechtold, J

    2002-01-01

    We used an experimental model producing a tissue response with a sclerotic endosteal neo-cortical rim associated with implant loosening in humans: a 6 mm PMMA cylinder pistoned 500 m concentrically in a 7.5 mm hole, with polyethylene particles. At a second operation at eight weeks, the standard revision procedure removed the fibrous membrane in one knee, and the crack revision procedure was used to crack the sclerotic endosteal rim in the contralateral knee. Once stability was achieved following the revision procedures, loaded Ti plasma sprayed implants were inserted into the revision cavities of 8 dogs for an additional 4 weeks. Revision implant fixation (ultimate shear strength and energy absorption) was significantly enhanced by cracking the sclerotic endosteal rim. In conclusion, we demonstrated a simple technique of cracking the sclerotic endosteal rim as an additional method for improving revision fixation. (Hip International 2002; 2: 77-9).

  19. Effects of low-modulus coatings on pin-bone contact stresses in external fixation.

    PubMed

    Manley, M T; Hurst, L; Hindes, R; Dee, R; Chiang, F P

    1984-01-01

    The intent of this study was to investigate the stress distribution in cortical bone around fracture fixation pins and around pins coated with various polymeric and elastomeric materials. Since these interface stresses cannot be measured directly, a photoelastic technique was employed and stresses were measured in two-dimensional bone models fabricated from sheets of epoxy resin. Our results showed that when a fixation pin was loaded in compression, the compressive stress measured in the model was greatest at the pin-model interface. The magnitude of the compressive stress was found to diminish steeply away from the hole in a log decrement distribution which was asymptotic to the value of the average stress in the model. When polymeric and elastomeric materials were applied as pin coatings and the performance of the coated pins was compared to that of uncoated pins of the same overall diameter, a reduction of the maximum stress in the bone model was demonstrated. Among the coatings tested, we found that of the polymeric materials ultrahigh molecular weight polyethylene (UHMWPE) was most effective at reducing the peak cortical stress magnitude. The most effective coating material overall was found to be silicon elastomer. Computation of stress values in models loaded through stainless-steel pins and through pins coated with 1-mm silicon elastomer showed that the presence of the elastomer layer caused a reduction of about 50% in the maximum compressive stress in the model.

  20. A numerical simulation of the effect of using porous superelastic Nitinol and stiff Titanium fixation hardware on the bone remodeling

    NASA Astrophysics Data System (ADS)

    Raad, Bahram; Shayesteh Moghaddam, Narges; Elahinia, Mohammad

    2016-04-01

    The aim of this article is to investigate the effect of two different fixation hardware materials on bone remodeling after a mandibular reconstruction surgery and to restore the mandible's function, healthy appearance, mastication, swallowing, breathing, and speech. The hypothesis is that using fixation hardware with stiffness close to that of the surrounding bone will result in a more successful healing process in the mandible bone. The finite element model includes the material properties and forces of the cancellous bone, cortical bone, ligaments, muscles, and teeth. The reconstruction surgery is modeled by including the fixation hardware and the grafted bone. In the sectioned mandible, to best mimic the geometry of the mandible, two single barrel grafts are placed at the top of each other to form a double barrel graft set. Two different materials were used as the mandibular fixation parts, stiff Ti-6Al-4V, and porous superelastic Nickel-Titanium (NiTi) alloys. A comparison of these two alloys demonstrates that using porous NiTi alloy as the fixation part results in a faster healing pace. Furthermore, the density distribution in the mandibular bone after the healing process is more similar to the normal mandible density distribution. The simulations results indicate that the porous superelastic NiTi fixation hardware transfers and distributes the existing forces on the mandible bone more favorably. The probability of stress shielding and/or stress concentration decrease. This type of fixation hardware, therefore, is more appropriate for mandible bone reconstruction surgery. These predictions are in agreement with the clinical observations.

  1. Feature-Based Visual Short-Term Memory Is Widely Distributed and Hierarchically Organized.

    PubMed

    Dotson, Nicholas M; Hoffman, Steven J; Goodell, Baldwin; Gray, Charles M

    2018-06-15

    Feature-based visual short-term memory is known to engage both sensory and association cortices. However, the extent of the participating circuit and the neural mechanisms underlying memory maintenance is still a matter of vigorous debate. To address these questions, we recorded neuronal activity from 42 cortical areas in monkeys performing a feature-based visual short-term memory task and an interleaved fixation task. We find that task-dependent differences in firing rates are widely distributed throughout the cortex, while stimulus-specific changes in firing rates are more restricted and hierarchically organized. We also show that microsaccades during the memory delay encode the stimuli held in memory and that units modulated by microsaccades are more likely to exhibit stimulus specificity, suggesting that eye movements contribute to visual short-term memory processes. These results support a framework in which most cortical areas, within a modality, contribute to mnemonic representations at timescales that increase along the cortical hierarchy. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Enhanced bone screw fixation with biodegradable bone cement in osteoporotic bone model.

    PubMed

    Juvonen, Tiina; Koistinen, Arto; Kröger, Heikki; Lappalainen, Reijo

    2012-09-27

    The purpose of this study was to study the potential of novel biodegradable PCL bone cement to improve bone screw fixation strength in osteoporotic bone. The biomechanical properties of bone cement (ε-polycaprolactone, PCL) and fixation strength were studied using biomechanical tests and bone screws fixed in an osteoporotic bone model. Removal torques and pullout strengths were assessed for cortical, self-tapping, and cancellous screws inserted in the osteoporotic bone model (polyurethane foam blocks with polycarbonate plate) with and without PCL bone cement. Open cell and cellular rigid foam blocks with a density of 0.12 g/cm3 were used in this model. Removal torques were significantly (more than six-fold) improved with bone cement for cancellous screws. Furthermore, the bone cement improved pullout strengths three to 12 times over depending on the screw and model material. Biodegradable bone cement turned out to be a very potential material to stabilize screw fixation in osteoporotic bone. The results warrant further research before safe clinical use, especially to clarify clinically relevant factors using real osteoporotic bone under human body conditions and dynamic fatigue testing for long-term performance.

  3. Grouping Inhibits Motion Fading by Giving Rise to Virtual Trackable Features

    ERIC Educational Resources Information Center

    Hsieh, P. -J.; Tse, P. U.

    2007-01-01

    After prolonged viewing of a slowly drifting or rotating pattern under strict fixation, the pattern appears to slow down and then momentarily stop. The authors show that grouping can slow down the process of "motion fading," suggesting that cortical configural form analysis interacts with the computation of motion signals during motion fading. The…

  4. Healing at the Interface Between Autologous Block Bone Grafts and Recipient Sites Using n-Butyl-2-Cyanoacrylate Adhesive as Fixation: Histomorphometric Study in Rabbits.

    PubMed

    De Santis, Enzo; Silva, Erick Ricardo; Martins, Evandro Neto Carneiro; Favero, Riccardo; Botticelli, Daniele; Xavier, Samuel Porfirio

    2017-12-01

    The aim of the present split-mouth (split-plot) study was to describe the sequential healing in the interface between autologous bone grafts and recipient parent bone, fixed using an n-butyl-2-cyanoacrylate adhesive with or without an additional titanium fixation screw. Bone grafts were collected from the calvaria and fixed to the lateral aspect of the mandible in 24 rabbits. The cortical layers of the recipient sites were perforated, and the grafts were randomly fixed using an n-butyl-2-cyanocrylate adhesive, either alone or in conjunction with a 1.5 mm × 6.0 mm titanium fixation screw. The animals were sacrificed after 3, 7, 20, and 40 days, and histomorphometric evaluations of the interface between graft and parent bone were performed. Only 2 of 6 grafts in each group were partially incorporated to the parent bone after 40 days of healing. The remaining grafts were separated from the parent bone by adhesive and connective tissue. It was concluded that the use of n-butyl-2-cyanoacrylate as fixation of an autologous bone graft to the lateral aspect of the mandible was able to maintain the fixation over time but did not incorporate the graft to the recipient sites. Use of fixation screws did not improve the healing.

  5. Amyotrophic lateral sclerosis affects cortical and subcortical activity underlying motor inhibition and action monitoring.

    PubMed

    Mohammadi, Bahram; Kollewe, Katja; Cole, David M; Fellbrich, Anja; Heldmann, Marcus; Samii, Amir; Dengler, Reinhard; Petri, Susanne; Münte, Thomas F; Krämer, Ulrike M

    2015-08-01

    Amyotrophic lateral sclerosis (ALS) is a neurodegenerative disorder characterized by muscular atrophy, spasticity, and bulbar signs caused by loss of upper and lower motor neurons. Evidence suggests that ALS additionally affects other brain areas including premotor cortex and supplementary motor area. Here, we studied movement execution and inhibition in ALS patients using a stop-signal paradigm and functional magnetic resonance imaging. Seventeen ALS patients and 17 age-matched healthy controls performed a stop-signal task that required responding with a button press to a right- or left-pointing black arrow (go-stimuli). In stop-trials, a red arrow (stop-stimulus) was presented shortly after the black arrow indicating to withhold the prepared movement. Patients had by trend higher reaction times in go-trials but did not differ significantly in their inhibition performance. Patients showed stronger inhibition-related activity in inferior, superior, and middle frontal gyri as well as in putamen and pallidum. Error-related activity, conversely, was found to be stronger in healthy controls, particularly in the insula bilaterally. Patients also showed increased activity in the motor cortex during button presses. The results provide evidence for altered prefrontal and subcortical networks underlying motor execution, motor inhibition, and error monitoring in ALS. © 2015 Wiley Periodicals, Inc.

  6. Random motor generation in a finger tapping task: influence of spatial contingency and of cortical and subcortical hemispheric brain lesions

    PubMed Central

    Annoni, J.; Pegna, A.

    1997-01-01

    OBJECTIVE—To test the hypothesis that, during random motor generation, the spatial contingencies inherent to the task would induce additional preferences in normal subjects, shifting their performances farther from randomness. By contrast, perceptual or executive dysfunction could alter these task related biases in patients with brain damage.
METHODS—Two groups of patients, with right and left focal brain lesions, as well as 25 right handed subjects matched for age and handedness were asked to execute a random choice motor task—namely, to generate a random series of 180 button presses from a set of 10 keys placed vertically in front of them.
RESULTS—In the control group, as in the left brain lesion group, motor generation was subject to deviations from theoretical expected randomness, similar to those when numbers are generated mentally, as immediate repetitions (successive presses on the same key) are avoided. However, the distribution of button presses was also contingent on the topographic disposition of the keys: the central keys were chosen more often than those placed at extreme positions. Small distances were favoured, particularly with the left hand. These patterns were influenced by implicit strategies and task related contingencies.
 By contrast, right brain lesion patients with frontal involvement tended to show a more square distribution of key presses—that is, the number of key presses tended to be more equally distributed. The strategies were also altered by brain lesions: the number of immediate repetitions was more frequent when the lesion involved the right frontal areas yielding a random generation nearer to expected theoretical randomness. The frequency of adjacent key presses was increased by right anterior and left posterior cortical as well as by right subcortical lesions, but decreased by left subcortical lesions.
CONCLUSIONS—Depending on the side of the lesion and the degree of cortical-subcortical involvement, the deficits take on a different aspect and direct repetions and adjacent key presses have different patterns of alterations. Motor random generation is therefore a complex task which seems to necessitate the participation of numerous cerebral structures, among which those situated in the right frontal, left posterior, and subcortical regions have a predominant role.

 PMID:9408109

  7. Comparison of visual field training for hemianopia with active versus sham transcranial direct cortical stimulation.

    PubMed

    Plow, Ela B; Obretenova, Souzana N; Fregni, Felipe; Pascual-Leone, Alvaro; Merabet, Lotfi B

    2012-01-01

    Vision Restoration Therapy (VRT) aims to improve visual field function by systematically training regions of residual vision associated with the activity of suboptimal firing neurons within the occipital cortex. Transcranial direct current stimulation (tDCS) has been shown to modulate cortical excitability. Assess the possible efficacy of tDCS combined with VRT. The authors conducted a randomized, double-blind, demonstration-of-concept pilot study where participants were assigned to either VRT and tDCS or VRT and sham. The anode was placed over the occipital pole to target both affected and unaffected lobes. One hour training sessions were carried out 3 times per week for 3 months in a laboratory. Outcome measures included objective and subjective changes in visual field, recording of visual fixation performance, and vision-related activities of daily living (ADLs) and quality of life (QOL). Although 12 participants were enrolled, only 8 could be analyzed. The VRT and tDCS group demonstrated significantly greater expansion in visual field and improvement on ADLs compared with the VRT and sham group. Contrary to expectations, subjective perception of visual field change was greater in the VRT and sham group. QOL did not change for either group. The observed changes in visual field were unrelated to compensatory eye movements, as shown with fixation monitoring. The combination of occipital cortical tDCS with visual field rehabilitation appears to enhance visual functional outcomes compared with visual rehabilitation alone. TDCS may enhance inherent mechanisms of plasticity associated with training.

  8. Interaction of root nodule size and oxygen pressure on the rate of nitrogen fixation by cowpea and peanut

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sen, D.; Weaver, R.W.

    1987-04-01

    Size and anatomical features of nodules influence the rate of O/sub 2/ diffusion into nodules. Availability of oxygen can be a limiting factor in nitrogen fixation. Larger nodules have thicker cortices and low surface to volume ratio leading to lower rates of gaseous diffusion. Increased oxygen pressure in the environment alters the rate of nitrogen fixation but the rate of change may depend on the nodule size. This was investigated by measuring /sup 15/N/sub 2/ incorporation into nodules. Root nodules from 38 day old cowpea and peanut plants were collected and sorted into size groups having diameters of >3 mm,more » 2-3 mm, and just below 2 mm. Samples of each size group were enclosed in tubes and exposed to various combination of oxygen (8-28%) and /sup 15/N/sub 2/. With higher O/sub 2/ pressure all nodules showed increased N/sub 2/ fixation but the largest nodules showed the maximum increase. Specific activity of larger nodules was higher for N/sub 2/ fixation. For the sizes of nodules examined the largest nodules did not reflect any of the disadvantages of the large size but the benefits of higher rates of O/sub 2/ entry was evident.« less

  9. Diagnosing Tic Disorders

    MedlinePlus

    ... span class="tp-sr-only">Submit Button Submit Button Systematic review of cortical bone trajectory versus pedicle screw techniques for lumbosacral spine fusion.

    PubMed

    Phan, Kevin; Ramachandran, Vignesh; Tran, Tommy M; Shah, Kevin P; Fadhil, Matthew; Lackey, Alan; Chang, Nicholas; Wu, Ai-Min; Mobbs, Ralph J

    2017-12-01

    Fusion of the lumbosacral spine is a common surgical procedure to address a range of spinal pathologies. Fixation in lumbar fusion has traditionally been performed using pedicle screw (PS) augmentation. However, an alternative method of screw insertion via cortical bone trajectory (CBT) has been advocated as a less invasive approach which improves initial fixation and reduces neurovascular injury. There is a paucity of robust clinical evidence to support these claims, particularly in comparison to traditional pedicle screws. This study aims to review the available evidence to assess the merits of the CBT approach. Six electronic databases were searched for original published studies which compared CBT with traditional PS and their findings reviewed. Nine comparative studies were identified through a comprehensive literature search. Studies were classified as retrospective cohort, prospective cohort or case control studies with medium quality as assessed by the GRADE criteria. The available literature is not cohesive regarding outcomes and complications of CBT versus PT procedures. Most studies found no difference in operative time, but reported less blood loss during CBT. Radiological outcomes show no difference in slippage at one year although CBT is associated with greater bone-density compared to PT. Results for post-operative pain are inconclusive.

  10. Orange Button Solar Data Exchange | Energy Analysis | NREL

    Science.gov Websites

    Orange Button Solar Data Exchange Orange Button Solar Data Exchange The new Orange Button Solar Data Exchange tool serves as an online resource for the solar industry to share, sell, or retrieve solar data and connect with colleagues. Screenshot image of Orange Button data website home page. The

  11. Tourette Syndrome (TS): Risk Factors and Causes

    MedlinePlus

    ... span class="tp-sr-only">Submit Button Submit Button Biomechanical evaluation of bone screw fixation with a novel bone cement.

    PubMed

    Juvonen, Tiina; Nuutinen, Juha-Pekka; Koistinen, Arto P; Kröger, Heikki; Lappalainen, Reijo

    2015-07-30

    Bone cement augmentation is commonly used to improve the fixation stability of orthopaedic implants in osteoporotic bone. The aim of this study was to evaluate the effect of novel bone cements on the stability of bone screw fixation by biomechanical testing and to compare them with a conventional Simplex(®)P bone cement and requirements of the standards. Basic biomechanical properties were compared with standard tests. Adhesion of bone cements were tested with polished, glass blasted and corundum blasted stainless steel surfaces. Screw pullout testing with/without cement was carried out using a synthetic bone model and cancellous and cortical bone screws. All the tested bone cements fulfilled the requirements of the standard for biomechanical properties and improved the screw fixation stability. Even a threefold increase in shear and tensile strength was achieved with increasing surface roughness. The augmentation improved the screw pullout force compared to fixation without augmentation, 1.2-5.7 times depending on the cement and the screw type. The good biomechanical properties of novel bone cement for osteoporotic bone were confirmed by experimental testing. Medium viscosity of the bone cements allowed easy handling and well-controlled penetration of bone cement into osteoporotic bone. By proper parameters and procedures it is possible to achieve biomechanically stable fixation in osteoporotic bone. Based on this study, novel biostable bone cements are very potential biomaterials to enhance bone screw fixation in osteoporotic bone. Novel bone cement is easy to use without hand mixing using a dual syringe and thus makes it possibility to use it as required during the operation.

  12. [Biphasic ceramic wedge and plate fixation with locked adjustable screws for open wedge tibial osteotomy].

    PubMed

    Lavallé, F; Pascal-Mousselard, H; Rouvillain, J L; Ribeyre, D; Delattre, O; Catonné, Y

    2004-10-01

    The aim of this radiological study was to evaluate the use of a biphasic ceramic wedge combined with plate fixation with locked adjustable screws for open wedge tibial osteotomy. Twenty-six consecutive patients (27 knees) underwent surgery between December 1999 and March 2002 to establish a normal lower-limb axis. The series included 6 women and 20 men, mean age 50 years (16 right knees and 11 left knees). Partial weight-bearing with crutches was allowed on day 1. A standard radiological assessment was performed on day 1, 90, and 360 (plain AP and lateral stance films of the knee). A pangonogram was performed before surgery and at day 360. Presence of a lateral metaphyseal space, development of peripheral cortical bridges, and osteointegration of the bone substitute-bone interface were evaluated used to assess bone healing. The medial tibial angle between the line tangent to the tibial plateau and the anatomic axis of the tibia (beta) was evaluated to assess preservation of postoperative correction. The HKA angle was determined. Three patients were lost to follow-up and 23 patients (24 knees) were retained for analysis. At last follow-up, presence of peripheral cortical bridges and complete filling of the lateral metaphyseal space demonstrated bone healing in all patients. Good quality osteointegration was achieved since 21 knees did not present an interface between the bone substitute and native bone (homogeneous transition zone). The beta angle was unchanged for 23 knees. A normal axis was observed in patients (16 knees) postoperatively. Use of a biphasic ceramic wedge in combination with plate fixation with locked adjustable screws is a reliable option for open wedge tibial osteotomy. The bone substitute fills the gap well. Tolerance and integration are optimal. Bone healing is achieved. Plate fixation with protected weight bearing appears to be a solid assembly, maintaining these corrections.

  13. A spatially nonselective baseline signal in parietal cortex reflects the probability of a monkey’s success on the current trial

    PubMed Central

    Zhang, Mingsha; Wang, Xiaolan; Goldberg, Michael E.

    2014-01-01

    We recorded the activity of neurons in the lateral intraparietal area of two monkeys while they performed two similar visual search tasks, one difficult, one easy. Each task began with a period of fixation followed by an array consisting of a single capital T and a number of lowercase t’s. The monkey had to find the capital T and report its orientation, upright or inverted, with a hand movement. In the easy task the monkey could explore the array with saccades. In the difficult task the monkey had to continue fixating and find the capital T in the visual periphery. The baseline activity measured during the fixation period, at a time in which the monkey could not know if the impending task would be difficult or easy or where the target would appear, predicted the monkey’s probability of success or failure on the task. The baseline activity correlated inversely with the monkey's recent history of success and directly with the intensity of the response to the search array on the current trial. The baseline activity was unrelated to the monkey’s spatial locus of attention as determined by the location of the cue in a cued visual reaction time task. We suggest that rather than merely reflecting the noise in the system, the baseline signal reflects the cortical manifestation of modulatory state, motivational, or arousal pathways, which determine the efficiency of cortical sensorimotor processing and the quality of the monkey’s performance. PMID:24889623

  14. Reverse total shoulder arthroplasty using helical blade to optimize glenoid fixation and bone preservation: preliminary results in thirty five patients with minimum two year follow-up.

    PubMed

    Zilber, Sebastien; Camana, Eleonora; Lapner, Peter; Haritinian, Emil; Nove Josserand, Laurent

    2018-03-26

    Glenoid loosening is a common cause of reverse total shoulder arthroplasty (RTSA) failure, and grafting of the glenoid is often required for revision due to bone loss due to the central peg in most glenoid baseplates. Helical blades have been used in the hip to optimize bone fixation in proximal femoral fracture. This study presents the initial results of specifically designed helical blade in the shoulder to optimize glenoid bone fixation and preservation as part of RTSA. Thirty-five patients underwent RTSA with glenoid helical blade fixation. An uncemented glenoid baseplate was used with a central helical blade partially coated with hydroxyapatite and two or three screws. Outcome analysis was performed pre-operatively and at two years. All patients were satisfied with the results and significant improvement was observed in functional outcome scores between baseline and final follow-up. There was a single intra-operative undisplaced glenoid fracture which did not compromise the baseplate fixation. There was no radiographic evidence of loosening or radiolucencies around the helical blade. The helical blade provides a satisfactory primary fixation. Because of its length (21 mm), care should be taken in cases of pre-existing bone loss or sclerotic bone to avoid glenoid fracture or anterior cortical perforation. Helical blade has the potential to facilitate glenoid implant revision by preserving the glenoid bone stock.

  15. Medial Patellofemoral Ligament Reconstruction Procedure Using a Suspensory Femoral Fixation System

    PubMed Central

    Nakagawa, Shuji; Arai, Yuji; Kan, Hiroyuki; Ueshima, Keiichiro; Ikoma, Kazuya; Terauchi, Ryu; Kubo, Toshikazu

    2013-01-01

    Recurrent patellar dislocation has recently been treated with anatomic medial patellofemoral ligament (MPFL) reconstruction using a semitendinosus muscle tendon. Although it is necessary to add tension to fix the tendon graft without loading excess stress on the patellofemoral joint, adjustment of the tension can be difficult. To resolve this problem, we developed an MPFL reconstruction procedure using the ToggleLoc Fixation Device (Biomet, Warsaw, IN), in which the semitendinosus muscle tendon is folded and used as a double-bundle tendon graft and 2 bone tunnels and 1 bone tunnel are made on the patellar and femoral sides, respectively. The patellar side of the tendon graft is fixed with an EndoButton (Smith & Nephew, London, England), and the femoral side is fixed with the ToggleLoc. Stepless adjustment of tension of the tendon graft is possible by reducing the size of the loop of the ToggleLoc hung onto the tendon graft. It may be useful to position the patella in the center of the femoral sulcus by confirming the patellofemoral joint fitting. Stability can be confirmed by loading lateral stress on the patella in the extended knee joint. This procedure is less invasive because opening of the lateral side of the femur is not necessary, and it may be useful for MPFL reconstruction. PMID:24892014

  16. Strength of titanium intramedullary implant versus miniplate fixation of mandibular condyle fractures.

    PubMed

    Frake, Paul C; Howell, Rebecca J; Joshi, Arjun S

    2012-07-01

    To test the strength of internal fixation of mandibular condyle fractures repaired with titanium miniplates versus titanium intramedullary implants. Prospective laboratory experimentation in urethane mandible models and human cadaveric mandibles. Materials testing laboratory at an academic medical center. Osteotomies of the mandibular condyle were created in 40 urethane hemimandible models and 24 human cadaveric specimens. Half of the samples in each group were repaired with traditional miniplates, and the other half were repaired with intramedullary titanium implants. Anteroposterior and mediolateral loads were applied to the samples, and the displacement was measured with reference to the applied force. Titanium intramedullary implants demonstrated statistically significant improved strength and stiffness versus miniplates in the urethane model experimental groups. Despite frequent plastic deformation and mechanical failures of the miniplates, a 1.6-mm-diameter titanium intramedullary pin did not mechanically fail in any of the cases. Intramedullary implantation failures were due to secondary fracture of the adjacent cortical bone or experimental design limitations including rotation of the smooth pin implant. Mechanical implant failures that were encountered with miniplate fixation were not seen with titanium intramedullary implants. These intramedullary implants provide stronger and more rigid fixation of mandibular condyle fractures than miniplates in this in vitro model.

  17. Management of Distal Tibial Metaphyseal Bone Defects With an Intramedullary Nitinol Scaffold: A Novel Technique.

    PubMed

    Ford, Samuel E; Ellington, J Kent

    2017-08-01

    Difficult problems that are faced when reconstructing severe pilon fractures include filling metaphyseal defects and supporting an impacted, multifragmented articular surface. Supplements to plate fixation currently available in a surgeon's armamentarium include cancellous bone autograft, structural bone allograft, demineralized bone matrix, and calcium-based cements. Cancellous autograft possesses limited inherent mechanical stability and is associated with graft site morbidity. Structural allografts incorporate inconsistently and are plagued by late resorption. Demineralized bone matrix also lacks inherent structural stability. Calcium phosphate cements are not rigidly fixed to bone unless fixation is applied from cortical bone or through a plate, which must be taken into consideration when planning fixation. The Conventus DRS (Conventus Orthopaedics, Maple Grove, MN) implant is an expandable nitinol scaffold that takes advantage of the elasticity and shape memory of nitinol alloy. Once deployed and locked, it serves as a stable intramedullary base for fragment-specific periarticular fracture fixation, even in the face of metaphyseal bone loss. Two cases of successful implant use are presented. In both cases, the implant is used to fill a metaphyseal void and provide stable articular support to the distal tibial plafond. Therapeutic Level V: Case Report, Expert Opinion.

  18. [Positive potentials of the human brain at different stages of preparation of a visually triggered saccade].

    PubMed

    Slavutskaia, M V; Shul'govskiĭ, V V

    2003-01-01

    The EEG of 10 right-handed subjects preceding saccades with mean values of latent periods were selected and averaged. Two standard paradigms of presentation of visual stimuli (central fixation stimulus-peripheral target succession): with a 200-ms inerstimulus interval (GAP) and successive single step (SS). During the period of central fixation, two kinds of positive potentials were observed: fast potentials of "inermediate" positivity (IP) developing 600-400 ms prior to saccade onset and fast potentials of "leading" positivity (LP), which immediately preceded the offset of the central fixation stimulus. Peak latency of the LP potentials was 300 ms prior to saccade onset in the SS paradigm and 400 ms in the GAP paradigm. These potentials were predominantly recorded in the frontal and frontosagittal cortical areas. Decrease in the latency by 30-50 ms in the GAP paradigm was associated with more pronounced positive potentials during the fixation period and absence of the initiation potential P-1' (or decrease in its amplitude). The obtained evidence suggest that the fast positive presaccadic potentials are of a complex nature related to attention, anticipation, motor preparation, decision making, saccadic initiation, and backward afferentation.

  1. Sensitive period in stereopsis: random dot stereopsis after long-standing strabismus.

    PubMed

    Hatch, S W; Laudon, R

    1993-12-01

    Bifoveal fixation is a requirement for random dot stereopsis. It is believed that random dot stereopsis is not possible after treatment of long-standing strabismus because binocular cortical cells are permanently damaged when strabismus is present during the sensitive period. Although the sensitive period for amblyopia has been clearly documented, the sensitive period for stereopsis is uncertain. We present a case we have followed from age 22 months to 10 years. This patient had intermittent esotropia until approximately age 3 years 4 months; he then had constant esotropia from about age 3 years 4 months to age 9 years 7 months. After orthoptic treatment at age 9 years, the patient returned to intermittent esotropia. He subsequently developed bifoveal fixation as measured by 30 sec arc of contour stereopsis and 250 to 500 sec arc of random dot stereopsis. This patient demonstrates that bifoveal fixation can be obtained after long-standing strabismus. We suggest that the sensitive period for stereopsis development, for this patient, was from birth to age 3 years.

  2. Illuminated push-button switch

    NASA Technical Reports Server (NTRS)

    Iwagiri, T.

    1983-01-01

    An illuminated push-button switch is described. It is characterized by the fact that is consists of a switch group, an operator button opening and closing the switch group, and a light-emitting element which illuminates the face of the operator button.

  3. Simultaneous bilateral distal biceps tendon ruptures repaired using an endobutton technique: a case report.

    PubMed

    Dacambra, Mark P; Walker, Richard Ea; Hildebrand, Kevin A

    2013-08-23

    The simultaneous rupture of both distal biceps tendons is a rare clinical entity that is difficult to treat and can have poor outcomes. A variety of treatment and rehabilitation options exist and have been reported for single sided and staged bilateral repairs, but none have described an approach for acute bilateral ruptures. Repairing distal biceps tendon ruptures using a single anterior incision and a cortical suspensory button technique has become increasingly popular in recent years. We present a report of our surgical approach using an endobutton technique and rehabilitation algorithm for this unusual injury pattern. A 43-year-old Caucasian man presented with acute onset bilateral elbow pain while lifting a large sheet of drywall off the ground. He initially felt a 'pop' on the right and almost immediately felt another on the left after having to quickly shift the weight. He was unable to continue working and sought medical attention. His pain was predominantly in his bilateral antecubital fossae and he had significant swelling and ecchymoses. His clinical examination demonstrated no palpable tendon, a retracted biceps muscle belly, and clear supination weakness. Magnetic resonance imaging was performed and showed bilateral distal biceps tendon ruptures with retraction on both sides. After discussion with our patient, we decided that both sides would be repaired using a single anterior incision with endobutton fixation, first his right followed by his left six weeks later. Overall, our patient did very well and had returned to full manual work by our last follow-up at 30 months. Although he was never able to return to competitive recreational hockey and was left with mild lateral antebrachial cutaneous nerve dysesthesias on his right, he felt he was at 85% of his premorbid level of function. We describe what we believe to be, to the best of our knowledge, the first case of simultaneous bilateral distal biceps tendon ruptures successfully treated with a single-incision endobutton technique, which represents a valid option in managing this difficult problem.

  4. 76 FR 54741 - Proposed Additions and Deletions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-02

    ...-6823--Button, Silver Oxide, 1.55V. NSN: 6135-01-538-0997--Button, Lithium, 3V. NSN: 6135-01-452-8160--Button, Lithium, 3V. NSN: 6135-01-301-8776--Lithium, AA, 3.6V . NSN: 6135-01-246-0307--Button, Silver...

  5. Contralateral Cortical Organisation of Information in Visual Short-Term Memory: Evidence from Lateralized Brain Activity during Retrieval

    ERIC Educational Resources Information Center

    Fortier-Gauthier, Ulysse; Moffat, Nicolas; Dell'Acqua, Robert; McDonald, John J.; Jolicoeur, Pierre

    2012-01-01

    We studied brain activity during retention and retrieval phases of two visual short-term memory (VSTM) experiments. Experiment 1 used a balanced memory array, with one color stimulus in each hemifield, followed by a retention interval and a central probe, at the fixation point that designated the target stimulus in memory about which to make a…

  6. Blue Button use by patients to access and share health record information using the Department of Veterans Affairs' online patient portal.

    PubMed

    Turvey, Carolyn; Klein, Dawn; Fix, Gemmae; Hogan, Timothy P; Woods, Susan; Simon, Steven R; Charlton, Mary; Vaughan-Sarrazin, Mary; Zulman, Donna M; Dindo, Lilian; Wakefield, Bonnie; Graham, Gail; Nazi, Kim

    2014-01-01

    The Blue Button feature of online patient portals promotes patient engagement by allowing patients to easily download their personal health information. This study examines the adoption and use of the Blue Button feature in the Department of Veterans Affairs' (VA) personal health record portal, My HealtheVet. An online survey presented to a 4% random sample of My HealtheVet users between March and May 2012. Questions were designed to determine characteristics associated with Blue Button use, perceived value of use, and how Veterans with non-VA providers use the Blue Button to share information with their non-VA providers. Of the survey participants (N=18 398), 33% were current Blue Button users. The most highly endorsed benefit was that it helped patients understand their health history better because all the information was in one place (73%). Twenty-one percent of Blue Button users with a non-VA provider shared their VA health information, and 87% reported that the non-VA provider found the information somewhat or very helpful. Veterans' self-rated computer ability was the strongest factor contributing to both Blue Button use and to sharing information with non-VA providers. When comparing Blue Button users and non-users, barriers to adoption were low awareness of the feature and difficulty using the Blue Button. This study contributes to the understanding of early Blue Button adoption and use of this feature for patient-initiated sharing of health information. Educational efforts are needed to raise awareness of the Blue Button and to address usability issues that hinder adoption. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Press-fit acetabular cup fixation: principles and testing.

    PubMed

    Macdonald, W; Carlsson, L V; Charnley, G J; Jacobsson, C M

    1999-01-01

    Pre-clinical testing of the fixation of press-fit acetabular components of total hip prostheses relies on cadaver or synthetic bone, but the properties and geometry of bone models differ from those of physiological bone. Cup designs use varied mechanisms for initial stability in bone; therefore, using different analogues and tests is appropriate. Press-fit cup stability was tested in the following: firstly, polyurethane (PU) foam modelling cancellous support; secondly, glass-fibre reinforced epoxide (GFRE) tubes modelling acetabular cortical support; thirdly, cadaveric acetabula. Three commercial cups [Harris-Galante II (H-G-II), Zimmer; Optifix, Smith & Nephew, Richards; porous coated anatomic (PCA), Howmedica] and an experimental cup with enhanced rim fixation were tested in three modes: direct pull-out, lever-out and axial torque. The fixation stabilities measured in the PU and the GFRE models showed trends consistent with those in cadaver bone, differing in the oversizing and cup geometry. The experimental cup was significantly more secure in most modes than other cups; the H-G II and Optifix cups showed similar stabilities, lower than that of the experimental cup but greater than that of the PCA cup (analysis of variance and Tukey's highly significant test; p < 0.001). The stabilities measured in cadaver bone more closely approximated those in GFRE. The use of several bone analogues enables separation of fixation mechanisms, allowing more accurate prediction of in vivo performance.

  8. Transarticular fixation with cortical screws combined with dorsal laminectomy and partial discectomy as surgical treatment of degenerative lumbosacral stenosis in 17 dogs: clinical and computed tomography follow-up.

    PubMed

    Golini, Lorenzo; Kircher, Patrick R; Lewis, Fraser I; Steffen, Frank

    2014-05-01

    To describe clinical outcome and technical outcome assessed using computed tomography (CT) in dogs with degenerative lumbosacral stenosis (DLSS) treated by dorsal laminectomy, partial discectomy, and transarticular screw fixation. Retrospective observational case series. Dogs with DLSS (n = 17). Dogs with neurologic and magnetic resonance imaging (MRI) findings compatible with DLSS treated by dorsal laminectomy, partial discectomy and transarticular screw fixation were enrolled. Pre- and postoperative neurologic status was compared. Lumbosacral (LS) angle in extension and misalignment in preoperative MRI were compared with the postoperative CT. Residual mobility of the LS joint after fixation was also evaluated. Status of screws, presence of new bone formation over screw heads/articular facets and presence of adjacent segment disease (ASD) were assessed. Median CT follow-up was 12 months. Clinical improvement was seen in 13 dogs, 2 dogs had intermittent LS pain, and 2 dogs needed revision surgery. In 5 dogs, screws were either pulled out or broken. Reduction of LS angle in extension and misalignment was achieved. Residual mobility of the LS segment was present and ASD was not recognized. Transarticular screw fixation in dogs with DLSS is associated with a considerable number of technical failures and does not result in rigid stabilization; however, this did not significantly adversely influence clinical outcome. © Copyright 2014 by The American College of Veterinary Surgeons.

  9. The effect of conscious intention to act on the Bereitschaftspotential.

    PubMed

    Takashima, Shiro; Cravo, André M; Sameshima, Koichi; Ramos, Renato T

    2018-06-02

    The current study investigated the effect of conscious intention to act on the Bereitschaftspotential. Situations in which the awareness of acting is minimally expressed were generated by asking 16 participants to press a button after performing a mental imagery task based on animal pictures (automatic condition). The affective responses induced by the pictures were controlled by selecting the animals according to different valences, threatening and neutral. The Bereitschaftspotential associated with the button presses was compared to the observed when similar movements were performed under the basic instructions of the self-paced movement paradigm (willed condition). Enhanced Bereitschaftspotential amplitudes were observed in the willed condition with respect to the automatic condition. This effect was manifested as a negative slope at medial frontocentral sites during the last 500 ms before movement onset. The valence of the pictures did not affect the motor preparatory potentials. The results suggest that significant part of the NS' subcomponent of the readiness potential is associated with the attention to-and, presumably, awareness of-intention to move, possibly reflecting cortical activation from supplementary motor areas. Secondarily, our findings supports that the feeling of threat does not influence the Bereitschaftspotential associated with automatic movements. Regarding methodological issues, the behavioural model of spontaneous voluntary movements proposed in automatic condition can benefit investigations on purely motor (or non-cognitive) subcomponents of the Bereitschaftspotential.

  10. Less-invasive stabilization of rib fractures by intramedullary fixation: a biomechanical evaluation.

    PubMed

    Bottlang, Michael; Helzel, Inga; Long, William; Fitzpatrick, Daniel; Madey, Steven

    2010-05-01

    This study evaluated intramedullary fixation of rib fractures with Kirschner wires and novel ribs splints. We hypothesized that rib splints can provide equivalent fixation strength while avoiding complications associated with Kirschner wires, namely wire migration and cutout. The durability, strength, and failure modes of rib fracture fixation with Kirschner wires and rib splints were evaluated in 22 paired human ribs. First, intact ribs were loaded to failure to determine their strength. After fracture fixation with Kirschner wires and rib splints, fixation constructs were dynamically loaded to 360,000 cycles at five times the respiratory load to determine their durability. Finally, constructs were loaded to failure to determine residual strength and failure modes. All constructs sustained dynamic loading without failure. Dynamic loading caused three times more subsidence in Kirschner wire constructs (1.2 mm +/- 1.4 mm) than in rib splint constructs (0.4 mm +/- 0.2 mm, p = 0.09). After dynamic loading, rib splint constructs remained 48% stronger than Kirschner wire constructs (p = 0.001). Five of 11 Kirschner wire constructs failed catastrophically by cutting through the medial cortex, leading to complete loss of stability and wire migration through the lateral cortex. The remaining six constructs failed by wire bending. Rib splint constructs failed by development of fracture lines along the superior and interior cortices. No splint construct failed catastrophically, and all splint constructs retained functional reduction and fixation. Because of their superior strength and absence of catastrophic failure mode, rib splints can serve as an attractive alternative to Kirschner wires for intramedullary stabilization of rib fractures, especially in the case of posterior rib fractures where access for plating is limited.

  11. Fleet Environmental | USFF

    Science.gov Websites

    Leadership Expand Leadership About NEPA Projects Expand NEPA Projects At Sea Expand At Sea Ashore Expand Ashore Stewards of the Sea Expand Stewards of the Sea Media Resources Expand Media Resources Contact NEPA Projects Button Environmental At Sea Button Environmental Ashore Button Energy Button Stewards of

  12. Grasping with the Press of a Button: Grasp-selective Responses in the Human Anterior Intraparietal Sulcus Depend on Nonarbitrary Causal Relationships between Hand Movements and End-effector Actions

    PubMed Central

    Frey, Scott H.; Hansen, Marc; Marchal, Noah

    2016-01-01

    Evidence implicates ventral parieto-premotor cortices in representing the goal of grasping independent of the movements or effectors involved [Umilta, M. A., Escola, L., Intskirveli, I., Grammont, F., Rochat, M., Caruana, F., et al. When pliers become fingers in the monkey motor system. Proceedings of the National Academy of Sciences, U.S.A., 105, 2209–2213, 2008; Tunik, E., Frey, S. H., & Grafton, S. T. Virtual lesions of the anterior intraparietal area disrupt goal-dependent on-line adjustments of grasp. Nature Neuroscience, 8, 505–511, 2005]. Modern technologies that enable arbitrary causal relationships between hand movements and tool actions provide a strong test of this hypothesis. We capitalized on this unique opportunity by recording activity with fMRI during tasks in which healthy adults performed goal-directed reach and grasp actions manually or by depressing buttons to initiate these same behaviors in a remotely located robotic arm (arbitrary causal relationship). As shown previously [Binkofski, F., Dohle, C., Posse, S., Stephan, K. M., Hefter, H., Seitz, R. J., et al. Human anterior intraparietal area subserves prehension: A combined lesion and functional MRI activation study. Neurology, 50, 1253–1259, 1998], we detected greater activity in the vicinity of the anterior intraparietal sulcus (aIPS) during manual grasp versus reach. In contrast to prior studies involving tools controlled by nonarbitrarily related hand movements [Gallivan, J. P., McLean, D. A., Valyear, K. F., & Culham, J. C. Decoding the neural mechanisms of human tool use. Elife, 2, e00425, 2013; Jacobs, S., Danielmeier, C., & Frey, S. H. Human anterior intraparietal and ventral premotor cortices support representations of grasping with the hand or a novel tool. Journal of Cognitive Neuroscience, 22, 2594–2608, 2010], however, responses within the aIPS and premotor cortex exhibited no evidence of selectivity for grasp when participants employed the robot. Instead, these regions showed comparable increases in activity during both the reach and grasp conditions. Despite equivalent sensorimotor demands, the right cerebellar hemisphere displayed greater activity when participants initiated the robot’s actions versus when they pressed a button known to be nonfunctional and watched the very same actions undertaken autonomously. This supports the hypothesis that the cerebellum predicts the forthcoming sensory consequences of volitional actions [Blakemore, S. J., Frith, C. D., & Wolpert, D. M. The cerebellum is involved in predicting the sensory consequences of action. NeuroReport, 12, 1879–1884, 2001]. We conclude that grasp-selective responses in the human aIPS and premotor cortex depend on the existence of nonarbitrary causal relationships between hand movements and end-effector actions. PMID:25436672

  13. Left-Lateralized Contributions of Saccades to Cortical Activity During a One-Back Word Recognition Task.

    PubMed

    Chang, Yu-Cherng C; Khan, Sheraz; Taulu, Samu; Kuperberg, Gina; Brown, Emery N; Hämäläinen, Matti S; Temereanca, Simona

    2018-01-01

    Saccadic eye movements are an inherent component of natural reading, yet their contribution to information processing at subsequent fixation remains elusive. Here we use anatomically-constrained magnetoencephalography (MEG) to examine cortical activity following saccades as healthy human subjects engaged in a one-back word recognition task. This activity was compared with activity following external visual stimulation that mimicked saccades. A combination of procedures was employed to eliminate saccadic ocular artifacts from the MEG signal. Both saccades and saccade-like external visual stimulation produced early-latency responses beginning ~70 ms after onset in occipital cortex and spreading through the ventral and dorsal visual streams to temporal, parietal and frontal cortices. Robust differential activity following the onset of saccades vs. similar external visual stimulation emerged during 150-350 ms in a left-lateralized cortical network. This network included: (i) left lateral occipitotemporal (LOT) and nearby inferotemporal (IT) cortex; (ii) left posterior Sylvian fissure (PSF) and nearby multimodal cortex; and (iii) medial parietooccipital (PO), posterior cingulate and retrosplenial cortices. Moreover, this left-lateralized network colocalized with word repetition priming effects. Together, results suggest that central saccadic mechanisms influence a left-lateralized language network in occipitotemporal and temporal cortex above and beyond saccadic influences at preceding stages of information processing during visual word recognition.

  14. Left-Lateralized Contributions of Saccades to Cortical Activity During a One-Back Word Recognition Task

    PubMed Central

    Chang, Yu-Cherng C.; Khan, Sheraz; Taulu, Samu; Kuperberg, Gina; Brown, Emery N.; Hämäläinen, Matti S.; Temereanca, Simona

    2018-01-01

    Saccadic eye movements are an inherent component of natural reading, yet their contribution to information processing at subsequent fixation remains elusive. Here we use anatomically-constrained magnetoencephalography (MEG) to examine cortical activity following saccades as healthy human subjects engaged in a one-back word recognition task. This activity was compared with activity following external visual stimulation that mimicked saccades. A combination of procedures was employed to eliminate saccadic ocular artifacts from the MEG signal. Both saccades and saccade-like external visual stimulation produced early-latency responses beginning ~70 ms after onset in occipital cortex and spreading through the ventral and dorsal visual streams to temporal, parietal and frontal cortices. Robust differential activity following the onset of saccades vs. similar external visual stimulation emerged during 150–350 ms in a left-lateralized cortical network. This network included: (i) left lateral occipitotemporal (LOT) and nearby inferotemporal (IT) cortex; (ii) left posterior Sylvian fissure (PSF) and nearby multimodal cortex; and (iii) medial parietooccipital (PO), posterior cingulate and retrosplenial cortices. Moreover, this left-lateralized network colocalized with word repetition priming effects. Together, results suggest that central saccadic mechanisms influence a left-lateralized language network in occipitotemporal and temporal cortex above and beyond saccadic influences at preceding stages of information processing during visual word recognition. PMID:29867372

  15. Bone microarchitecture of the tibial plateau in skeletal health and osteoporosis.

    PubMed

    Krause, Matthias; Hubert, Jan; Deymann, Simon; Hapfelmeier, Alexander; Wulff, Birgit; Petersik, Andreas; Püschel, Klaus; Amling, Michael; Hawellek, Thelonius; Frosch, Karl-Heinz

    2018-05-07

    Impaired bone structure poses a challenge for the treatment of osteoporotic tibial plateau fractures. As knowledge of region-specific structural bone alterations is a prerequisite to achieving successful long-term fixation, the aim of the current study was to characterize tibial plateau bone structure in patients with osteoporosis and the elderly. Histomorphometric parameters were assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT) in 21 proximal tibiae from females with postmenopausal osteoporosis (mean age: 84.3 ± 4.9 years) and eight female healthy controls (45.5 ± 6.9 years). To visualize region-specific structural bony alterations with age, the bone mineral density (Hounsfield units) was additionally analyzed in 168 human proximal tibiae. Statistical analysis was based on evolutionary learning using globally optimal regression trees. Bone structure deterioration of the tibial plateau due to osteoporosis was region-specific. Compared to healthy controls (20.5 ± 4.7%) the greatest decrease in bone volume fraction was found in the medio-medial segments (9.2 ± 3.5%, p < 0.001). The lowest bone volume was found in central segments (tibial spine). Trabecular connectivity was severely reduced. Importantly, in the anterior and posterior 25% of the lateral and medial tibial plateaux, trabecular support and subchondral cortical bone thickness itself were also reduced. Thinning of subchondral cortical bone and marked bone loss in the anterior and posterior 25% of the tibial plateau should require special attention when osteoporotic patients require fracture fixation of the posterior segments. This knowledge may help to improve the long-term, fracture-specific fixation of complex tibial plateau fractures in osteoporosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Finding and recognizing objects in natural scenes: complementary computations in the dorsal and ventral visual systems

    PubMed Central

    Rolls, Edmund T.; Webb, Tristan J.

    2014-01-01

    Searching for and recognizing objects in complex natural scenes is implemented by multiple saccades until the eyes reach within the reduced receptive field sizes of inferior temporal cortex (IT) neurons. We analyze and model how the dorsal and ventral visual streams both contribute to this. Saliency detection in the dorsal visual system including area LIP is modeled by graph-based visual saliency, and allows the eyes to fixate potential objects within several degrees. Visual information at the fixated location subtending approximately 9° corresponding to the receptive fields of IT neurons is then passed through a four layer hierarchical model of the ventral cortical visual system, VisNet. We show that VisNet can be trained using a synaptic modification rule with a short-term memory trace of recent neuronal activity to capture both the required view and translation invariances to allow in the model approximately 90% correct object recognition for 4 objects shown in any view across a range of 135° anywhere in a scene. The model was able to generalize correctly within the four trained views and the 25 trained translations. This approach analyses the principles by which complementary computations in the dorsal and ventral visual cortical streams enable objects to be located and recognized in complex natural scenes. PMID:25161619

  17. Active versus passive listening to auditory streaming stimuli: a near-infrared spectroscopy study

    NASA Astrophysics Data System (ADS)

    Remijn, Gerard B.; Kojima, Haruyuki

    2010-05-01

    We use near-infrared spectroscopy (NIRS) to assess listeners' cortical responses to a 10-s series of pure tones separated in frequency. Listeners are instructed to either judge the rhythm of these ``streaming'' stimuli (active-response listening) or to listen to the stimuli passively. Experiment 1 shows that active-response listening causes increases in oxygenated hemoglobin (oxy-Hb) in response to all stimuli, generally over the (pre)motor cortices. The oxy-Hb increases are significantly larger over the right hemisphere than over the left for the final 5 s of the stimulus. Hemodynamic levels do not vary with changes in the frequency separation between the tones and corresponding changes in perceived rhythm (``gallop,'' ``streaming,'' or ``ambiguous''). Experiment 2 shows that hemodynamic levels are strongly influenced by listening mode. For the majority of time windows, active-response listening causes significantly larger oxy-Hb increases than passive listening, significantly over the left hemisphere during the stimulus and over both hemispheres after the stimulus. This difference cannot be attributed to physical motor activity and preparation related to button pressing after stimulus end, because this is required in both listening modes.

  18. Active versus passive listening to auditory streaming stimuli: a near-infrared spectroscopy study.

    PubMed

    Remijn, Gerard B; Kojima, Haruyuki

    2010-01-01

    We use near-infrared spectroscopy (NIRS) to assess listeners' cortical responses to a 10-s series of pure tones separated in frequency. Listeners are instructed to either judge the rhythm of these "streaming" stimuli (active-response listening) or to listen to the stimuli passively. Experiment 1 shows that active-response listening causes increases in oxygenated hemoglobin (oxy-Hb) in response to all stimuli, generally over the (pre)motor cortices. The oxy-Hb increases are significantly larger over the right hemisphere than over the left for the final 5 s of the stimulus. Hemodynamic levels do not vary with changes in the frequency separation between the tones and corresponding changes in perceived rhythm ("gallop," "streaming," or "ambiguous"). Experiment 2 shows that hemodynamic levels are strongly influenced by listening mode. For the majority of time windows, active-response listening causes significantly larger oxy-Hb increases than passive listening, significantly over the left hemisphere during the stimulus and over both hemispheres after the stimulus. This difference cannot be attributed to physical motor activity and preparation related to button pressing after stimulus end, because this is required in both listening modes.

  19. --No Title--

    Science.gov Websites

    {margin:0;padding:0;border:0;outline:0;line-height:1.3;text-decoration:none;font-size:100%;list-style:none -state-disabled{cursor:default!important}.ui-icon{display:block;text-indent:-99999px;overflow:hidden -align:middle;text-align:center;overflow:visible}.ui-button,.ui-button:link,.ui-button:visited,.ui-button:hover

  20. Button battery intake as foreign body in Chinese children: review of case reports and the literature.

    PubMed

    Liao, Wenjing; Wen, Guangyi; Zhang, Xiaowen

    2015-06-01

    Button batteries have been recognized as one of the dangerous foreign bodies to children for more than 30 years, but few related studies have been published to give more concern in China. We reported 6 cases of button battery intake as foreign body in children. The Chinese literature on button battery as foreign body in children was reviewed. The interval between the accidental ingestion and battery removal ranged from 6 hours to 3 days. Two patients had no sequela, 3 patients had tracheoesophageal fistulas, and 1 patient had nasal septal perforation. Twenty-eight articles about button battery as foreign body in children were obtained by Chinese-language literature searches including 25 case reports, 2 health education articles, and 1 imaging article. In total, 172 cases of button battery intake as foreign body in children were identified, 23 and 10 of the 159 cases involving nasal button battery lodgment developed nasal septal perforation and nasal adhesion, respectively. Tracheoesophageal fistula was identified in 4 of the 12 ingestion cases. One case of button battery intake was in external auditory canal. A small number of children with button battery as foreign body were reported in China, which is 1 of the biggest countries with large population of children.

  1. Severity of button batteries ingestions: data from French Poison Control Centres between 1999 and 2015.

    PubMed

    Labadie, Magali; O'Mahony, Elisabeth; Capaldo, Lise; Courtois, Arnaud; Lamireau, Thierry; Nisse, Patrick; Blanc-Brisset, Ingrid; Puskarczyk, Emmanuel

    2017-12-13

    Although the ingestion of button batteries is an infrequent situation, it leads to a significant risk of causing serious damage. This study was carried out to describe all the cases of button battery ingestion recorded by the French Poison Control Centers over 16 years. All the cases of button battery ingestion were recorded from 1 January 1999 to the end of June 2015, analysed (age, sex, number of ingested button batteries, clinical signs and treatments) and graded for severity according to the poisoning severity score. The incidence of button batteries ingestions was constant over the 16-year period, with an average of 266±98.5 cases per year and a total of 4030 cases. Nevertheless, 21 cases were severe and two deaths occurred. Interestingly, for the two patients who died, the battery was stuck in the oesophagus and they presented anorexia and/or dysphagia, abdominal pain and fever and in one case, a melena 3 weeks after ingestion. Importantly, these symptoms were observed even if the battery was expelled in one fatal case. Ingestions of button batteries still occur and may cause serious damage, especially in children, and if the button battery is stuck in the oesophagus as it might cause severe symptoms. Patients who have ingested a button battery must be directed to the emergency department for medical evaluation, even if the button battery has been expelled from the body and even more if gastrointestinal symptoms are present.

  2. Action Monitoring Cortical Activity Coupled to Submovements

    PubMed Central

    Sobolewski, Aleksander

    2017-01-01

    Numerous studies have examined neural correlates of the human brain’s action-monitoring system during experimentally segmented tasks. However, it remains unknown how such a system operates during continuous motor output when no experimental time marker is available (such as button presses or stimulus onset). We set out to investigate the electrophysiological correlates of action monitoring when hand position has to be repeatedly monitored and corrected. For this, we recorded high-density electroencephalography (EEG) during a visuomotor tracking task during which participants had to follow a target with the mouse cursor along a visible trajectory. By decomposing hand kinematics into naturally occurring periodic submovements, we found an event-related potential (ERP) time-locked to these submovements and localized in a sensorimotor cortical network comprising the supplementary motor area (SMA) and the precentral gyrus. Critically, the amplitude of the ERP correlated with the deviation of the cursor, 110 ms before the submovement. Control analyses showed that this correlation was truly due to the cursor deviation and not to differences in submovement kinematics or to the visual content of the task. The ERP closely resembled those found in response to mismatch events in typical cognitive neuroscience experiments. Our results demonstrate the existence of a cortical process in the SMA, evaluating hand position in synchrony with submovements. These findings suggest a functional role of submovements in a sensorimotor loop of periodic monitoring and correction and generalize previous results from the field of action monitoring to cases where action has to be repeatedly monitored. PMID:29071301

  3. A newly designed hydroxyapatite ceramic burr-hole button

    PubMed Central

    Kashimura, Hiroshi; Ogasawara, Kuniaki; Kubo, Yoshitaka; Yoshida, Kenji; Sugawara, Atsushi; Ogawa, Akira

    2010-01-01

    Conventional burr-hole buttons sometimes do not fit the burr hole well due to the curvature of the surrounding bone. An irregular surface at the border between the button and the surrounding skull may appear unaesthetic. The major problem is the difference between the curvature radius of the skull and the burr-hole button in contact with the skull. To solve this problem, the authors designed a button made of hydroxyapatite ceramic to snugly fit the burr hole. The specifications of this device and its clinical application are described here. PMID:20448795

  4. A newly designed hydroxyapatite ceramic burr-hole button.

    PubMed

    Kashimura, Hiroshi; Ogasawara, Kuniaki; Kubo, Yoshitaka; Yoshida, Kenji; Sugawara, Atsushi; Ogawa, Akira

    2010-03-24

    Conventional burr-hole buttons sometimes do not fit the burr hole well due to the curvature of the surrounding bone. An irregular surface at the border between the button and the surrounding skull may appear unaesthetic. The major problem is the difference between the curvature radius of the skull and the burr-hole button in contact with the skull. To solve this problem, the authors designed a button made of hydroxyapatite ceramic to snugly fit the burr hole. The specifications of this device and its clinical application are described here.

  5. High-throughput automated home-cage mesoscopic functional imaging of mouse cortex

    PubMed Central

    Murphy, Timothy H.; Boyd, Jamie D.; Bolaños, Federico; Vanni, Matthieu P.; Silasi, Gergely; Haupt, Dirk; LeDue, Jeff M.

    2016-01-01

    Mouse head-fixed behaviour coupled with functional imaging has become a powerful technique in rodent systems neuroscience. However, training mice can be time consuming and is potentially stressful for animals. Here we report a fully automated, open source, self-initiated head-fixation system for mesoscopic functional imaging in mice. The system supports five mice at a time and requires minimal investigator intervention. Using genetically encoded calcium indicator transgenic mice, we longitudinally monitor cortical functional connectivity up to 24 h per day in >7,000 self-initiated and unsupervised imaging sessions up to 90 days. The procedure provides robust assessment of functional cortical maps on the basis of both spontaneous activity and brief sensory stimuli such as light flashes. The approach is scalable to a number of remotely controlled cages that can be assessed within the controlled conditions of dedicated animal facilities. We anticipate that home-cage brain imaging will permit flexible and chronic assessment of mesoscale cortical function. PMID:27291514

  6. View of button board which accommodates the 1200 button switches ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of button board which accommodates the 1200 button switches which manually control the indicating pilot lights on the model board. Not all switches are active, some switches were installed for a planned, but never constructed, system expansion. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  7. A fast button surface defects detection method based on convolutional neural network

    NASA Astrophysics Data System (ADS)

    Liu, Lizhe; Cao, Danhua; Wu, Songlin; Wu, Yubin; Wei, Taoran

    2018-01-01

    Considering the complexity of the button surface texture and the variety of buttons and defects, we propose a fast visual method for button surface defect detection, based on convolutional neural network (CNN). CNN has the ability to extract the essential features by training, avoiding designing complex feature operators adapted to different kinds of buttons, textures and defects. Firstly, we obtain the normalized button region and then use HOG-SVM method to identify the front and back side of the button. Finally, a convolutional neural network is developed to recognize the defects. Aiming at detecting the subtle defects, we propose a network structure with multiple feature channels input. To deal with the defects of different scales, we take a strategy of multi-scale image block detection. The experimental results show that our method is valid for a variety of buttons and able to recognize all kinds of defects that have occurred, including dent, crack, stain, hole, wrong paint and uneven. The detection rate exceeds 96%, which is much better than traditional methods based on SVM and methods based on template match. Our method can reach the speed of 5 fps on DSP based smart camera with 600 MHz frequency.

  8. Spontaneous and training-induced cortical plasticity in MD patients: Hints from lateral masking.

    PubMed

    Maniglia, Marcello; Soler, Vincent; Cottereau, Benoit; Trotter, Yves

    2018-01-08

    Macular degeneration (MD) affects central vision and represents the leading cause of visual diseases in elderly population worldwide. As a consequence of central vision loss, MD patients develop a preferred retinal locus (PRL), an eccentric fixation point that replaces the fovea. Here, our aim was to determine whether and to what extent spontaneous plasticity takes place in the cortical regions formerly responding to central vision and whether a visual training based on perceptual learning (PL) can boost this plasticity within the PRL area. Spontaneous and PL-induced cortical plasticity were characterized by using lateral masking, a contrast sensitivity modulation induced by collinear flankers. This configuration is known to be sensitive to neural plasticity and underlies several rehabilitation trainings. Results in a group of 4 MD patients showed that collinear facilitation was similar to what observed in age- and eccentricity-matched controls. However, MD patients exhibited significantly reduced collinear inhibition, a sign of neural plasticity, consistent with the hypothesis of partial cortical reorganization. Three AMD patients from the same group showed a further reduction of inhibition after training, but not controls. This result suggests that PL might further boost neural plasticity, opening promising perspectives for the development of rehabilitation protocols for MD patients.

  9. Emotive concept nouns and motor responses: attraction or repulsion?

    PubMed

    Freina, Laura; Baroni, Giulia; Borghi, Anna M; Nicoletti, Roberto

    2009-06-01

    We carried out three experiments aimed at testing whether hand posture affects the compatibility effect that Chen and Bargh (1999) found between a word's emotional connotation and arm movement direction. In the present study, participants responded by pressing two buttons: one placed near their body, the other far away. In Experiment 1, in which they pressed the response button with their hand open, RTs were shorter when participants pressed the far button for positive words and the near button for negative words, as if they simulated reaching for something good and avoiding something bad. However, in Experiments 2 and 3, in which participants pressed the response button with a tennis ball in their hand, RTs were shorter when participants pressed the near button for positive words and the far button for negative words, as if they simulated drawing a good thing closer and pushing a bad thing away. Results are discussed within the framework of theories on concept grounding in emotion and action systems.

  10. Internal rib structure can be predicted using mathematical models: An anatomic study comparing the chest to a shell dome with application to understanding fractures.

    PubMed

    Casha, Aaron R; Camilleri, Liberato; Manché, Alexander; Gatt, Ruben; Attard, Daphne; Gauci, Marilyn; Camilleri-Podesta, Marie-Therese; Mcdonald, Stuart; Grima, Joseph N

    2015-11-01

    The human rib cage resembles a masonry dome in shape. Masonry domes have a particular construction that mimics stress distribution. Rib cortical thickness and bone density were analyzed to determine whether the morphology of the rib cage is sufficiently similar to a shell dome for internal rib structure to be predicted mathematically. A finite element analysis (FEA) simulation was used to measure stresses on the internal and external surfaces of a chest-shaped dome. Inner and outer rib cortical thickness and bone density were measured in the mid-axillary lines of seven cadaveric rib cages using computerized tomography scanning. Paired t tests and Pearson correlation were used to relate cortical thickness and bone density to stress. FEA modeling showed that the stress was 82% higher on the internal than the external surface, with a gradual decrease in internal and external wall stresses from the base to the apex. The inner cortex was more radio-dense, P < 0.001, and thicker, P < 0.001, than the outer cortex. Inner cortical thickness was related to internal stress, r = 0.94, P < 0.001, inner cortical bone density to internal stress, r = 0.87, P = 0.003, and outer cortical thickness to external stress, r = 0.65, P = 0.035. Mathematical models were developed relating internal and external cortical thicknesses and bone densities to rib level. The internal anatomical features of ribs, including the inner and outer cortical thicknesses and bone densities, are similar to the stress distribution in dome-shaped structures modeled using FEA computer simulations of a thick-walled dome pressure vessel. Fixation of rib fractures should include the stronger internal cortex. © 2015 Wiley Periodicals, Inc.

  11. Increase of cortical bone after a cementless long stem in periprosthetic fractures.

    PubMed

    García-Rey, Eduardo; García-Cimbrelo, Eduardo; Cruz-Pardos, Ana; Madero, Rosário

    2013-12-01

    Healing and functional recovery have been reported using an extensively porous-coated stem in Vancouver B2 and B3 periprosthetic fractures; however, loss of cortical bone has been observed when using these stems in revision surgery for aseptic loosening. However, it is unclear whether this bone loss influences subsequent loosening. We analyze the healing fracture rate and whether the radiographic changes observed around and extensively porous-coated stem used for periprosthetic fractures affect function or loosening. We retrospectively reviewed 35 patients with periprosthetic fractures (20 Vancouver B2 and 15 Vancouver B3). Patients' mean age at surgery was 80 years (range, 51-86 years). No cortical struts were used in this series. We evaluated radiographs for signs of loosening or subsidence. The cortical index and the femoral cortical width were measured at different levels on the immediate pre- and postoperative radiographs and at different periods of followup. The minimum followup was 3 years (mean, 8.3 years; range, 3-17 years). All fractures had healed, and all stems were clinically and radiographically stable at the end of followup. Nineteen hips showed nonprogressive radiographic subsidence during the first 3 postoperative months without clinical consequences. The cortical index and the lateral and medial cortical thickness increased over time. Increase of femoral cortex thicknesses was greater in cases with moderate preoperative osteoporosis and in cases with stems less than 16 mm in thickness. Our data suggest an extensively porous-coated stem for Vancouver B2 and B3 periprosthetic fractures leads to a high rate of union and stable fixation. Cortical index and lateral cortex thickness increased in these patients with periprosthetic fractures. Patients with moderate osteoporosis and those using thin stems showed a major increase in femoral cortex thickness over time.

  12. Conflict between aftereffects of retinal sweep and looming motion.

    PubMed

    Bridgeman, B; Nardello, C

    1994-01-01

    Observers looked monocularly into a tunnel, with gratings on the left and right sides drifting toward the head. An exposure period was followed by a test with fixed gratings. With fixation points, left and right retinal fields could be stimulated selectively. When exposure and test were on the same retinal fields, but fixation was on opposite sides of the tunnel during exposure and test periods, aftereffects of retinal sweep and of perceived looming were in opposite directions. The two effects tended to cancel, yielding no perceived aftereffect. When they did occur, aftereffects in the retinal and the looming directions were equally likely. Cancellation was significantly more likely in the experimental conditions than in the control, when fixation always remained on the same side. When areas of retinal stimulation in the exposure and test periods did not overlap, cancellation was less frequent and aftereffects of looming were more frequent. Results were not significantly different for left and right visual fields, indicating that cortical vs. subcortical OKN pathways do not influence the illusion. Vection resulted for 16 of 20 observers under one or another of our conditions.

  13. Does immediate elbow mobilization after distal biceps tendon repair carry the risk of wound breakdown, failure of repair, or patient dissatisfaction?

    PubMed

    Smith, James R A; Amirfeyz, Rouin

    2016-05-01

    Rehabilitation protocols after distal biceps repair are highly variable, with many surgeons favoring at least 2 weeks of immobilization. Is this conservative approach necessary to protect the repair? This was a consecutive series of 22 distal biceps tendon repairs in which a cortical button system was used. Patients were encouraged to mobilize their elbow actively from the day of surgery. Physiotherapy commenced at 3 weeks, with strengthening exercises when full range of movement (ROM) was achieved. The primary outcome measured was the clinical integrity of the repaired tendon. Secondary outcomes comprised wound or nerve complication, elbow ROM, and patient-reported outcome measures (the 11-item version of the Disabilities of Arm, Shoulder and Hand, Mayo Elbow Performance Index, and Oxford Elbow Score). All patients were male, and the dominant arm was repaired in 60%. Mean age was 40.6 years (range, 27-62 years), and mean time to surgery was 17 days (range, 5-99 days). Mean follow-up was 16.6 months (range, 3.8-29 months). All tendons were clinically intact at time of review. No wound breakdown occurred. Mean extension was -6° (range, -10° to 10°), and flexion was 144° (range, 135°-150°). All patients achieved full pronosupination. ROM was equivalent to the uninjured arm (P = .7). The mean 11-item version of the Disabilities of Arm, Shoulder and Hand score was 2.7 (range, 0-15.9), the Mayo Elbow Performance Index was 97.8 (range, 70-100), and the Oxford Elbow Score was 46.9 (range, 43-48) at the latest follow-up. One-third of patients experienced a transient sensory neurapraxia. Immediate mobilization after biceps tendon repair with a cortical button is possible, and in this series was not associated with failure of the repair, wound breakdown, or patient dissatisfaction. However, this series emphasizes the high incidence of nerve complication that can be associated with the single transverse incision technique. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  14. The Emerging Role of 3-Dimensional Printing in Rhinology.

    PubMed

    Stokken, Janalee K; Pallanch, John F

    2017-06-01

    Nasal septal perforations, particularly those that are large and irregular in shape, often present as challenging surgical dilemmas. New technology has allowed us to develop techniques using computed tomography imaging and 3-dimensional (3D) printers to design custom polymeric silicone septal buttons. These buttons offer patients an option that avoids a surgical intervention when standard buttons do not fit well or are not tolerated. Preliminary data suggest that buttons designed by 3D printer technology provide more comfort than standard commercially available or hand-carved buttons with equivalent reduction of symptoms. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Quantified histopathology of the keratoconic cornea.

    PubMed

    Mathew, Jessica H; Goosey, John D; Bergmanson, Jan P G

    2011-08-01

    This study systematically investigated and quantified histopathological changes in a series of keratoconic (Kc) corneas using a physiologically formulated fixative to not further distort the already distorted diseased corneas. Twelve surgically removed Kc corneal buttons were immediately preserved and processed for light and transmission electron microscopy using an established corneal protocol. Measurements were taken from the central cone and peripheral regions of the host button. The sample size examined ranged in length from 390 to 2608 μm centrally and 439 to 2242 μm peripherally. The average corneal thickness was 437 μm centrally and 559 μm peripherally. Epithelial thickness varied centrally from 14 to 92 μm and peripherally from 30 to 91 μm. A marked thickening of the epithelial basement membrane was noted in 58% of corneas. Centrally, anterior limiting lamina (ALL) was thinned or lost over 60% of the area examined, whereas peripheral cornea was also affected but to a lesser extent. Histopathologically, posterior cornea remained undisturbed by the disease. Anteriorly in the stroma, an increased number of cells and tissue debris were encountered, and some of these cells were clearly not keratocytes. It is concluded that Kc pathology, at least initially, has a distinct anterior focus involving the epithelium, ALL, and anterior stroma. The epithelium had lost its cellular uniformity and was compromised by the loss or damage to the ALL. The activity of the hitherto unreported recruited stromal cells may be to break down and remove ALL and anterior stromal lamellae, leading to the overall thinning that accompanies this disease.

  16. [Distal clavicle fracture].

    PubMed

    Seppel, G; Lenich, A; Imhoff, A B

    2014-06-01

    Reposition and fixation of unstable distal clavicle fractures with a low profile locking plate (Acumed, Hempshire, UK) in conjunction with a button/suture augmentation cerclage (DogBone/FibreTape, Arthrex, Naples, FL, USA). Unstable fractures of the distal clavicle (Jäger and Breitner IIA) in adults. Unstable fractures of the distal clavicle (Jäger and Breitner IV) in children. Distal clavicle fractures (Jäger and Breitner I, IIB or III) with marked dislocation, injury of nerves and vessels, or high functional demand. Patients in poor general condition. Fractures of the distal clavicle (Jäger and Breitner I, IIB or III) without marked dislocation or vertical instability. Local soft-tissue infection. Combination procedure: Initially the lateral part of the clavicle is exposed by a 4 cm skin incision. After reduction of the fracture, stabilization is performed with a low profile locking distal clavicle plate. Using a special guiding device, a transclavicular-transcoracoidal hole is drilled under arthroscopic view. Additional vertical stabilization is arthroscopically achieved by shuttling the DogBone/FibreTape cerclage from the lateral portal cranially through the clavicular plate. The two ends of the FibreTape cerclage are brought cranially via adjacent holes of the locking plate while the DogBone button is placed under the coracoid process. Thus, plate bridging is achieved. Finally reduction is performed and the cerclage is secured by surgical knotting. Use of an arm sling for 6 weeks. Due to the fact that the described technique is a relatively new procedure, long-term results are lacking. In the short term, patients postoperatively report high subjective satisfaction without persistent pain.

  17. Plasma-sprayed titanium coating to polyetheretherketone improves the bone-implant interface.

    PubMed

    Walsh, William R; Bertollo, Nicky; Christou, Chrisopher; Schaffner, Dominik; Mobbs, Ralph J

    2015-05-01

    Rapid and stable fixation at the bone-implant interface would be regarded as one of the primary goals to achieve clinical efficacy, regardless of the surgical site. Although mechanical and physical properties of polyetheretherketone (PEEK) provide advantages for implant devices, the hydrophobic nature and the lack of direct bone contact remains a limitation. To examine the effects of a plasma-sprayed titanium coated PEEK on the mechanical and histologic properties at the bone-implant interface. A preclinical laboratory study. Polyetheretherketone and plasma-sprayed titanium coated PEEK implants (Ti-bond; Spinal Elements, Carlsbad, CA, USA) were placed in a line-to-line manner in cortical bone and in a press-fit manner in cancellous bone of adult sheep using an established ovine model. Shear strength was assessed in the cortical sites at 4 and 12 weeks, whereas histology was performed in cortical and cancellous sites at both time points. The titanium coating dramatically improved the shear strength at the bone-implant interface at 4 weeks and continued to improve with time compared with PEEK. Direct bone ongrowth in cancellous and cortical sites can be achieved using a plasma-sprayed titanium coating on PEEK. Direct bone to implant bonding can be achieved on PEEK in spite of its hydrophobic nature using a plasma-sprayed titanium coating. The plasma-sprayed titanium coating improved mechanical properties in the cortical sites and the histology in cortical and cancellous sites. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Use of the Blue Button Online Tool for Sharing Health Information: Qualitative Interviews With Patients and Providers.

    PubMed

    Klein, Dawn M; Fix, Gemmae M; Hogan, Timothy P; Simon, Steven R; Nazi, Kim M; Turvey, Carolyn L

    2015-08-18

    Information sharing between providers is critical for care coordination, especially in health systems such as the United States Department of Veterans Affairs (VA), where many patients also receive care from other health care organizations. Patients can facilitate this sharing by using the Blue Button, an online tool that promotes patients' ability to view, print, and download their health records. The aim of this study was to characterize (1) patients' use of Blue Button, an online information-sharing tool in VA's patient portal, My HealtheVet, (2) information-sharing practices between VA and non-VA providers, and (3) how providers and patients use a printed Blue Button report during a clinical visit. Semistructured qualitative interviews were conducted with 34 VA patients, 10 VA providers, and 9 non-VA providers. Interviews focused on patients' use of Blue Button, information-sharing practices between VA and non-VA providers, and how patients and providers use a printed Blue Button report during a clinical visit. Qualitative themes were identified through iterative rounds of coding starting with an a priori schema based on technology adoption theory. Information sharing between VA and non-VA providers relied primarily on the patient. Patients most commonly used Blue Button to access and share VA laboratory results. Providers recognized the need for improved information sharing, valued the Blue Button printout, and expressed interest in a way to share information electronically across settings. Consumer-oriented technologies such as Blue Button can facilitate patients sharing health information with providers in other health care systems; however, more education is needed to inform patients of this use to facilitate care coordination. Additional research is needed to explore how personal health record documents, such as Blue Button reports, can be easily shared and incorporated into the clinical workflow of providers.

  19. Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.

    PubMed

    Wegner, Adam M; Wolinsky, Philip R; Robbins, Michael A; Garcia, Tanya C; Amanatullah, Derek F

    2018-05-01

    Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. Specimens were subjected to offset axial tension loading on a servohydraulic testing system and tracked using high-resolution video. Failure was defined as 2 mm of articular displacement. Analysis of variance followed by a Tukey-Kramer post hoc test was used to assess for differences between groups, with significance defined as P<.05. The mean stiffness (±SD) values of both mini-fragment T-plate constructs (239±83 N/mm and 190±37 N/mm) and the bicortical screw construct (240±17 N/mm) were not statistically different. The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.]. Copyright 2018, SLACK Incorporated.

  20. Influence of cup-center-edge angle on micro-motion at the interface between the cup and host bone in cementless total hip arthroplasty: three-dimensional finite element analysis.

    PubMed

    Kaku, Nobuhiro; Tabata, Tomonori; Tsumura, Hiroshi

    2015-12-01

    We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was <40 μm. Even if transplanted bulk bone is used, unless good fixation is obtained between the host bone, and the cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle <-10° and slippage exceeding 40 μm. Bulk bone grafting tightly fixed to the host bone improves initial the cup-host bone fixation, especially when the cup-CE angle is small, such as <-10°. In clinical practice, negative factors are implicated in the initial fixation of various cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.

  1. Virtual button interface

    DOEpatents

    Jones, Jake S.

    1999-01-01

    An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch.

  2. Effect of blood contamination on shear bond strength of orthodontic brackets and disinclusion buttons.

    PubMed

    Sfondrini, Maria Francesca; Gatti, Sara; Scribante, Andrea

    2011-07-01

    Our aim was to assess the effect of blood contamination on the shear bonding strength and sites of failure of orthodontic brackets and bondable buttons. We randomly divided 160 bovine permanent mandibular incisors into 8 groups of 20 specimens each. Both orthodontic brackets (Step brackets, Leone, Sesto Fiorentino, Italy) and bondable buttons (Flat orthodontic buttons, Leone, Sesto Fiorentino, Italy) were tested on four different enamel surfaces: dry; contamination with blood before priming; after priming; and before and after priming. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bonding strength and the rate of adhesive failures were recorded. Data were analysed using the analysis of variance (ANOVA), Scheffè tests, and the chi-square test. Uncontaminated enamel surfaces showed the highest bonding strengths for both brackets and buttons. When they were contaminated with blood, orthodontic brackets had significantly lower shear strengths than bondable buttons (P=0.0001). There were significant differences in sites of failure among the groups for the various enamel surfaces (P=0.001). Contamination of enamel by blood during bonding lowers the strength of the bond, more so with orthodontic brackets than with bondable buttons. Copyright © 2010 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Increased Cortical Activity in Binge Drinkers during Working Memory Task: A Preliminary Assessment through a Functional Magnetic Resonance Imaging Study

    PubMed Central

    Campanella, Salvatore; Peigneux, Philippe; Petit, Géraldine; Lallemand, Frédéric; Saeremans, Mélanie; Noël, Xavier; Metens, Thierry; Nouali, Mustapha; De Tiège, Xavier; De Witte, Philippe; Ward, Roberta; Verbanck, Paul

    2013-01-01

    Background Cerebral dysfunction is a common feature of both chronic alcohol abusers and binge drinkers. Here, we aimed to study whether, at equated behavioral performance levels, binge drinkers exhibited increased neural activity while performing simple cognitive tasks. Methods Thirty-two participants (16 binge drinkers and 16 matched controls) were scanned using functional magnetic resonance imaging (fMRI) while performing an n-back working memory task. In the control zero-back (N0) condition, subjects were required to press a button with the right hand when the number “2″ was displayed. In the two-back (N2) condition, subjects had to press a button when the displayed number was identical to the number shown two trials before. Results fMRI analyses revealed higher bilateral activity in the pre-supplementary motor area in binge drinkers than matched controls, even though behavioral performances were similar. Moreover, binge drinkers showed specific positive correlations between the number of alcohol doses consumed per occasion and higher activity in the dorsomedial prefrontal cortex, as well as between the number of drinking occasions per week and higher activity in cerebellum, thalamus and insula while performing the N2 memory task. Conclusions Binge alcohol consumption leads to possible compensatory cerebral changes in binge drinkers that facilitate normal behavioral performance. These changes in cerebral responses may be considered as vulnerability factors for developing adult substance use disorders. PMID:23638017

  4. Widgets and Buttons

    MedlinePlus

    ... Home → Widgets and Buttons URL of this page: https://medlineplus.gov/widgets.html Widgets and Buttons To ... link the word MedlinePlus to the MedlinePlus homepage ( https://medlineplus.gov/ ). Search MedlinePlus : To put the MedlinePlus ...

  5. Shear bond strength of orthodontic brackets and disinclusion buttons: effect of water and saliva contamination.

    PubMed

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola; Scribante, Andrea

    2013-01-01

    The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons.

  6. Virtual button interface

    DOEpatents

    Jones, J.S.

    1999-01-12

    An apparatus and method of issuing commands to a computer by a user interfacing with a virtual reality environment are disclosed. To issue a command, the user directs gaze at a virtual button within the virtual reality environment, causing a perceptible change in the virtual button, which then sends a command corresponding to the virtual button to the computer, optionally after a confirming action is performed by the user, such as depressing a thumb switch. 4 figs.

  7. EEG alpha activity and hallucinatory experience during sensory deprivation.

    PubMed

    Hayashi, M; Morikawa, T; Hori, T

    1992-10-01

    The relationship between hallucinatory experiences under sensory deprivation and EEG alpha activities was studied. Each of seven male students lived alone in an air conditioned, soundproof dark room for 72 hours. When hallucinatory experiences occurred, the students pressed a button at once. If they could not press the button during the experience, they were required to press it two times when the hallucinatory experience was finished. Spectral analysis was performed on the consecutive EEG samples from just before button-presses to 10 min. before them, and the average alpha band amplitudes were obtained for the four epochs (0-.5, .5-2, 2-5, 5-10 min.). For the single button-presses, the amplitude of alpha band increased 2 min. before the button-presses. Right-hemisphere EEG activation was observed in the occipital area for the double button-presses. The results suggest an association between the hallucinatory experiences under sensory deprivation and the amount of EEG alpha activity.

  8. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box.

    PubMed

    Harness, Neil G

    2016-03-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41-82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70-64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0-2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates.

  9. Fixation Options for the Volar Lunate Facet Fracture: Thinking Outside the Box

    PubMed Central

    Harness, Neil G.

    2016-01-01

    Background Fractures of the distal radius with small volar ulnar marginal fracture fragments are difficult to stabilize with standard volar locking plates. The purpose of this study is to describe alternative techniques available to stabilize these injuries. Materials and Methods Five patients were identified retrospectively with unstable volar lunate facet fracture fragments treated with supplemental fixation techniques. The demographic data, pre- and postoperative radiographic parameters, and early outcomes data were analyzed. The AO classification, preoperative and final postoperative ulnar variance, articular step-off, volar tilt, radial inclination, and teardrop angle were measured. The lunate subsidence and length of the volar cortex available for fixation were measured from the initial injury films. Description of Technique Lunate facet fixation was based on the morphology of the fragment, and stabilization was achieved with headless compression screws in three patients, a tension band wire construct in one, and two cortical screws in another. Results Five patients with a mean age of 58 years (range: 41–82) were included. There were two AO C3.2 and three B3.3 fractures. Preoperative radiographic measurements including radial inclination, tilt, and ulnar variance all improved after surgery and were maintained within normal limits at 3-month follow-up. There was no change in the teardrop angle at final follow-up (70–64 degrees; p = 0.14). None of the patients had loss of fixation or volar carpal subluxation. The mean visual analog scale pain score at 3 months was 1 (range: 0–2). Conclusions The morphology of volar lunate facet fracture fragments is variable, and fixation must be customized to the particular pattern. Small fragments may preclude the use of plates and screws for fixation. These fractures can be managed successfully with tension band wire constructs and headless screws. These low-profile implants may decrease the risk of tendon irritation that might accompany distally placed plates. PMID:26855830

  10. The anesthetic management of button battery ingestion in children.

    PubMed

    Ing, Richard J; Hoagland, Monica; Mayes, Lena; Twite, Mark

    2018-03-01

    Injuries related to button battery ingestion are common in children. This review provides an outline of the epidemiology, pathophysiology, management, and anesthetic implications in children who have ingested a button battery. A literature search was conducted in the United States National Library of Medicine PubMed database using the terms "button battery ingestion" and "children' and "removal" and "surgery" and "anesthesia". Ninety-six articles published in English were found from 1983-2017, and 62 of these articles were incorporated into this review. Additionally, the Internet was searched with the terms "button battery ingestion and children" to identify further entities, organizations, and resources affiliated with button battery ingestion in children. These additional sources were studied and included in this review. Button batteries are ubiquitous in homes and electronic devices. Since 2006, larger-diameter and higher-voltage batteries have become available. These are more likely to become impacted in the esophagus after ingestion and lead to an increase in severe morbidity and mortality due to caustic tissue injury. Children at the highest risk for complications are those under six years of age who have ingested batteries > 20 mm in diameter and sustain prolonged esophageal impaction at the level of the aortic arch with the negative pole oriented anteriorly. Anesthesiologists need to know about the epidemiology, pathophysiology, complications, and anesthetic management of children who have ingested button batteries.

  11. Use of the Blue Button Online Tool for Sharing Health Information: Qualitative Interviews With Patients and Providers

    PubMed Central

    Fix, Gemmae M; Hogan, Timothy P; Simon, Steven R; Nazi, Kim M; Turvey, Carolyn L

    2015-01-01

    Background Information sharing between providers is critical for care coordination, especially in health systems such as the United States Department of Veterans Affairs (VA), where many patients also receive care from other health care organizations. Patients can facilitate this sharing by using the Blue Button, an online tool that promotes patients’ ability to view, print, and download their health records. Objective The aim of this study was to characterize (1) patients’ use of Blue Button, an online information-sharing tool in VA’s patient portal, My HealtheVet, (2) information-sharing practices between VA and non-VA providers, and (3) how providers and patients use a printed Blue Button report during a clinical visit. Methods Semistructured qualitative interviews were conducted with 34 VA patients, 10 VA providers, and 9 non-VA providers. Interviews focused on patients’ use of Blue Button, information-sharing practices between VA and non-VA providers, and how patients and providers use a printed Blue Button report during a clinical visit. Qualitative themes were identified through iterative rounds of coding starting with an a priori schema based on technology adoption theory. Results Information sharing between VA and non-VA providers relied primarily on the patient. Patients most commonly used Blue Button to access and share VA laboratory results. Providers recognized the need for improved information sharing, valued the Blue Button printout, and expressed interest in a way to share information electronically across settings. Conclusions Consumer-oriented technologies such as Blue Button can facilitate patients sharing health information with providers in other health care systems; however, more education is needed to inform patients of this use to facilitate care coordination. Additional research is needed to explore how personal health record documents, such as Blue Button reports, can be easily shared and incorporated into the clinical workflow of providers. PMID:26286139

  12. Shear Bond Strength of Orthodontic Brackets and Disinclusion Buttons: Effect of Water and Saliva Contamination

    PubMed Central

    Sfondrini, Maria Francesca; Fraticelli, Danilo; Gandini, Paola

    2013-01-01

    Purpose. The aim of this study was to assess the effect of water and saliva contamination on the shear bond strength and failure site of orthodontic brackets and lingual buttons. Materials and Methods. 120 bovine permanent mandibular incisors were randomly divided into 6 groups of 20 specimens each. Both orthodontic brackets and disinclusion buttons were tested under three different enamel surface conditions: (a) dry, (b) water contamination, and (c) saliva contamination. Brackets and buttons were bonded to the teeth and subsequently tested using a Instron universal testing machine. Shear bond strength values and adhesive failure rate were recorded. Statistical analysis was performed using ANOVA and Tukey tests (strength values) and Chi squared test (ARI Scores). Results. Noncontaminated enamel surfaces showed the highest bond strengths for both brackets and buttons. Under water and saliva contamination orthodontic brackets groups showed significantly lower shear strengths than disinclusion buttons groups. Significant differences in debond locations were found among the groups under the various enamel surface conditions. Conclusions. Water and saliva contamination of enamel during the bonding procedure lowers bond strength values, more with orthodontic brackets than with disinclusion buttons. PMID:23762825

  13. Test-retest reliability of fMRI during nonverbal semantic decisions in moderate-severe nonfluent aphasia patients

    PubMed Central

    Kurland, Jacquie; Naeser, Margaret A.; Baker, Errol H.; Doron, Karl; Martin, Paula I.; Seekins, Heidi E.; Bogdan, Andrew; Renshaw, Perry; Yurgelun-Todd, Deborah

    2005-01-01

    Cortical reorganization in poststroke aphasia is not well understood. Few studies have investigated neural mechanisms underlying language recovery in severe aphasia patients, who are typically viewed as having a poor prognosis for language recovery. Although test-retest reliability is routinely demonstrated during collection of language data in single-subject aphasia research, this is rarely examined in fMRI studies investigating the underlying neural mechanisms in aphasia recovery. The purpose of this study was to acquire fMRI test-retest data examining semantic decisions both within and between two aphasia patients. Functional MRI was utilized to image individuals with chronic, moderate-severe nonfluent aphasia during nonverbal, yes/no button-box semantic judgments of iconic sentences presented in the Computer-assisted Visual Communication (C-ViC) program. We investigated the critical issue of intra-subject reliability by exploring similarities and differences in regions of activation during participants’ performance of identical tasks twice on the same day. Each participant demonstrated high intra-subject reliability, with response decrements typical of task familiarity. Differences between participants included greater left hemisphere perilesional activation in the individual with better response to C-ViC training. This study provides fMRI reliability in chronic nonfluent aphasia, and adds to evidence supporting differences in individual cortical reorganization in aphasia recovery. PMID:15706052

  14. Evaluation of Heat Dissipation in the BPM Buttons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Blednyhk, A.

    2009-05-04

    Growth of circulating current in the storage rings drastically increases heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of the pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the NSLS-II BPM buttons design.

  15. Radiographic evaluation of bone adaptation adjacent to percutaneous osseointegrated prostheses in a sheep model.

    PubMed

    Jeyapalina, Sujee; Beck, James Peter; Bachus, Kent N; Chalayon, Ornusa; Bloebaum, Roy D

    2014-10-01

    Percutaneous osseointegrated prostheses (POPs) are being investigated as an alternative to conventional socket suspension and require a radiographic followup in translational studies to confirm that design objectives are being met. In this 12-month animal study, we determined (1) radiographic signs of osseointegration and (2) radiographic signs of periprosthetic bone hypertrophy and resorption (adaptation) and (3) confirmed them with the histologic evidence of host bone osseointegration and adaptation around a novel, distally porous-coated titanium POP with a collar. A POP device was designed to fit the right metacarpal bone of sheep. Amputation and implantation surgeries (n = 14) were performed, and plane-film radiographs were collected quarterly for 12 months. Radiographs were assessed for osseointegration (fixation) and bone adaptation (resorption and hypertrophy). The cortical wall and medullary canal widths were used to compute the cortical index and expressed as a percentage. Based on the cortical index changes and histologic evaluations, bone adaptation was quantified. Radiographic data showed signs of osseointegration including those with incomplete seating against the collar attachment. Cortical index data indicated distal cortical wall thinning if the collar was not seated distally. When implants were bound proximally, bone resorbed distally and the diaphyseal cortex hypertrophied. Histopathologic evidence and cortical index measurements confirmed the radiographic indications of adaptation and osseointegration. Distal bone loading, through collar attachment and porous coating, limited the distal bone resorption. Serial radiographic studies, in either animal models or preclinical trials for new POP devices, will help to determine which designs are likely to be safe over time and avoid implant failures.

  16. Long-range traveling waves of activity triggered by local dichoptic stimulation in V1 of behaving monkeys

    PubMed Central

    Yang, Zhiyong; Heeger, David J.; Blake, Randolph

    2014-01-01

    Traveling waves of cortical activity, in which local stimulation triggers lateral spread of activity to distal locations, have been hypothesized to play an important role in cortical function. However, there is conflicting physiological evidence for the existence of spreading traveling waves of neural activity triggered locally. Dichoptic stimulation, in which the two eyes view dissimilar monocular patterns, can lead to dynamic wave-like fluctuations in visual perception and therefore, provides a promising means for identifying and studying cortical traveling waves. Here, we used voltage-sensitive dye imaging to test for the existence of traveling waves of activity in the primary visual cortex of awake, fixating monkeys viewing dichoptic stimuli. We find clear traveling waves that are initiated by brief, localized contrast increments in one of the monocular patterns and then, propagate at speeds of ∼30 mm/s. These results demonstrate that under an appropriate visual context, circuitry in visual cortex in alert animals is capable of supporting long-range traveling waves triggered by local stimulation. PMID:25343785

  17. Patients with mild cognitive impairment have an abnormal upper-alpha event-related desynchronization/synchronization (ERD/ERS) during a task of temporal attention.

    PubMed

    Caravaglios, Giuseppe; Muscoso, Emma Gabriella; Di Maria, Giulia; Costanzo, Erminio

    2015-03-01

    There are several evidences indicating that an impairment in attention-executive functions is present in prodromal Alzheimer's disease and predict future global cognitive decline. In particular, the issue of temporal orienting of attention in patients with mild cognitive impairment (MCI) due to Alzheimer's disease has been overlooked. The present research aimed to explore whether subtle deficits of cortical activation are present in these patients early in the course of the disease. We studied the upper-alpha event-related synchronization/desynchronization phenomenon during a paradigm of temporal orientation of attention. MCI patients (n = 27) and healthy elderly controls (n = 15) performed a task in which periodically omitted tones had to be predicted and their virtual onset time had to be marked by pressing a button. Single-trial responses were measured, respectively, before and after the motor response. Then, upper-alpha responses were compared to upper-alpha power during eyes-closed resting state. The time course of the task was characterized by two different behavioral conditions: (1) a pre-event epoch, in which the subject awaited the virtual onset of the omitted tone, (2) a post-event epoch (after button pressing), in which the subject was in a post-motor response condition. The principal findings are: (1) during the waiting epoch, only healthy elderly had an upper-alpha ERD at the level of both temporal and posterior brain regions; (2) during the post-motor epoch, the aMCI patients had a weaker upper-alpha ERS on prefrontal regions; (3) only healthy elderly showed a laterality effect: (a) during the waiting epoch, the upper-alpha ERD was greater at the level of the right posterior-temporal lead; during the post-motor epoch, the upper alpha ERS was greater on the left prefrontal lead. The relevance of these findings is that the weaker upper-alpha response observed in aMCI patients is evident even if the accuracy of the behavioral performance (i.e., button pressing) is still spared. This abnormal upper-alpha response might represent an early biomarker of the attention-executive network impairment in MCI due to Alzheimer's disease.

  18. Comparative Study of button BPM Trapped Mode Heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Singh, O.

    2009-05-04

    The combination of short bunches and high currents found in modern light sources and colliders can result in the deposition of tens of watts of power in BPM buttons. The resulting thermal distortion is potentially problematic for maintaining high precision beam position stability, and in the extreme case can result in mechanical damage. We present a simple algorithm that uses the input parameters of beam current, bunch length, button diameter, beampipe aperture, and fill pattern to calculate a relative figure-of-merit for button heating. Data for many of the world's light sources and colliders is compiled in a table. Using themore » algorithm, the table is sorted in order of the relative magnitude of button heating.« less

  19. Effect of drivers' age and push button locations on visual time off road, steering wheel deviation and safety perception.

    PubMed

    Dukic, T; Hanson, L; Falkmer, T

    2006-01-15

    The study examined the effects of manual control locations on two groups of randomly selected young and old drivers in relation to visual time off road, steering wheel deviation and safety perception. Measures of visual time off road, steering wheel deviations and safety perception were performed with young and old drivers during real traffic. The results showed an effect of both driver's age and button location on the dependent variables. Older drivers spent longer visual time off road when pushing the buttons and had larger steering wheel deviations. Moreover, the greater the eccentricity between the normal line of sight and the button locations, the longer the visual time off road and the larger the steering wheel deviations. No interaction effect between button location and age was found with regard to visual time off road. Button location had an effect on perceived safety: the further away from the normal line of sight the lower the rating.

  20. Mechanical and structural characteristics of the new BONE-LOK cortical-cancellous internal fixation device.

    PubMed

    Cachia, Victor V; Culbert, Brad; Warren, Chris; Oka, Richard; Mahar, Andrew

    2003-01-01

    The purpose of this study was to evaluate the structural and mechanical characteristics of a new and unique titanium cortical-cancellous helical compression anchor with BONE-LOK (Triage Medical, Inc., Irvine, CA) technology for compressive internal fixation of fractures and osteotomies. This device provides fixation through the use of a distal helical anchor and a proximal retentive collar that are united by an axially movable pin (U.S. and international patents issued and pending). The helical compression anchor (2.7-mm diameter) was compared with 3.0-mm diameter titanium cancellous screws (Synthes, Paoli, PA) for pullout strength and compression in 7# and 12# synthetic rigid polyurethane foam (simulated bone matrix), and for 3-point bending stiffness. The following results (mean +/- standard deviation) were obtained: foam block pullout strength in 12# foam: 2.7-mm helical compression anchor 70 +/- 2.0 N and 3.0-mm titanium cancellous screws 37 +/- 11 N; in 7# foam: 2.7-mm helical compression anchor 33 +/- 3 N and 3.0-mm titanium cancellous screws 31 +/- 12 N. Three-point bending stiffness, 2.7-mm helical compression anchor 988 +/- 68 N/mm and 3.0-mm titanium cancellous screws 845 +/- 88 N/mm. Compression strength testing in 12# foam: 2.7-mm helical compression anchor 70.8 +/- 4.8 N and 3.0-mm titanium cancellous screws 23.0 +/- 3.1 N, in 7# foam: 2.7-mm helical compression anchor 42.6 +/- 3.2 N and 3.0-mm titanium cancellous screws 10.4 +/- 0.9 N. Results showed greater pullout strength, 3-point bending stiffness, and compression strength for the 2.7-mm helical compression anchor as compared with the 3.0-mm titanium cancellous screws in these testing models. This difference represents a distinct advantage in the new device that warrants further in vivo testing.

  1. Characterization of Femoral Component Initial Stability and Cortical Strain in a Reduced Stem-Length Design.

    PubMed

    Small, Scott R; Hensley, Sarah E; Cook, Paige L; Stevens, Rebecca A; Rogge, Renee D; Meding, John B; Berend, Michael E

    2017-02-01

    Short-stemmed femoral components facilitate reduced exposure surgical techniques while preserving native bone. A clinically successful stem should ideally reduce risk for stress shielding while maintaining adequate primary stability for biological fixation. We asked (1) how stem-length changes cortical strain distribution in the proximal femur in a fit-and-fill geometry and (2) if short-stemmed components exhibit primary stability on par with clinically successful designs. Cortical strain was assessed via digital image correlation in composite femurs implanted with long, medium, and short metaphyseal fit-and-fill stem designs in a single-leg stance loading model. Strain was compared to a loaded, unimplanted femur. Bone-implant micromotion was then compared with reduced lateral shoulder short stem and short tapered-wedge designs in cyclic axial and torsional testing. Femurs implanted with short-stemmed components exhibited cortical strain response most closely matching that of the intact femur model, theoretically reducing the potential for proximal stress shielding. In micromotion testing, no difference in primary stability was observed as a function of reduced stem length within the same component design. Our findings demonstrate that within this fit-and-fill stem design, reduction in stem length improved proximal cortical strain distribution and maintained axial and torsional stability on par with other stem designs in a composite femur model. Short-stemmed implants may accommodate less invasive surgical techniques while facilitating more physiological femoral loading without sacrificing primary implant stability. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. The effects of decreased audibility produced by high-pass noise masking on cortical event-related potentials to speech sounds/ba/and/da.

    PubMed

    Martin, B A; Sigal, A; Kurtzberg, D; Stapells, D R

    1997-03-01

    This study investigated the effects of decreased audibility produced by high-pass noise masking on cortical event-related potentials (ERPs) N1, N2, and P3 to the speech sounds /ba/and/da/presented at 65 and 80 dB SPL. Normal-hearing subjects pressed a button in response to the deviant sound in an oddball paradigm. Broadband masking noise was presented at an intensity sufficient to completely mask the response to the 65-dB SPL speech sounds, and subsequently high-pass filtered at 4000, 2000, 1000, 500, and 250 Hz. With high-pass masking noise, pure-tone behavioral thresholds increased by an average of 38 dB at the high-pass cutoff and by 50 dB one octave above the cutoff frequency. Results show that as the cutoff frequency of the high-pass masker was lowered, ERP latencies to speech sounds increased and amplitudes decreased. The cutoff frequency where these changes first occurred and the rate of the change differed for N1 compared to N2, P3, and the behavioral measures. N1 showed gradual changes as the masker cutoff frequency was lowered. N2, P3, and behavioral measures showed marked changes below a masker cutoff of 2000 Hz. These results indicate that the decreased audibility resulting from the noise masking affects the various ERP components in a differential manner. N1 is related to the presence of audible stimulus energy, being present whether audible stimuli are discriminable or not. In contrast, N2 and P3 were absent when the stimuli were audible but not discriminable (i.e., when the second formant transitions were masked), reflecting stimulus discrimination. These data have implications regarding the effects of decreased audibility on cortical processing of speech sounds and for the study of cortical ERPs in populations with hearing impairment.

  3. Simultaneous bilateral distal biceps tendon ruptures repaired using an endobutton technique: a case report

    PubMed Central

    2013-01-01

    Introduction The simultaneous rupture of both distal biceps tendons is a rare clinical entity that is difficult to treat and can have poor outcomes. A variety of treatment and rehabilitation options exist and have been reported for single sided and staged bilateral repairs, but none have described an approach for acute bilateral ruptures. Repairing distal biceps tendon ruptures using a single anterior incision and a cortical suspensory button technique has become increasingly popular in recent years. We present a report of our surgical approach using an endobutton technique and rehabilitation algorithm for this unusual injury pattern. Case presentation A 43-year-old Caucasian man presented with acute onset bilateral elbow pain while lifting a large sheet of drywall off the ground. He initially felt a ‘pop’ on the right and almost immediately felt another on the left after having to quickly shift the weight. He was unable to continue working and sought medical attention. His pain was predominantly in his bilateral antecubital fossae and he had significant swelling and ecchymoses. His clinical examination demonstrated no palpable tendon, a retracted biceps muscle belly, and clear supination weakness. Magnetic resonance imaging was performed and showed bilateral distal biceps tendon ruptures with retraction on both sides. After discussion with our patient, we decided that both sides would be repaired using a single anterior incision with endobutton fixation, first his right followed by his left six weeks later. Conclusion Overall, our patient did very well and had returned to full manual work by our last follow-up at 30 months. Although he was never able to return to competitive recreational hockey and was left with mild lateral antebrachial cutaneous nerve dysesthesias on his right, he felt he was at 85% of his premorbid level of function. We describe what we believe to be, to the best of our knowledge, the first case of simultaneous bilateral distal biceps tendon ruptures successfully treated with a single-incision endobutton technique, which represents a valid option in managing this difficult problem. PMID:23972255

  4. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  5. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  6. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  7. 46 CFR 160.037-3 - Materials, workmanship, construction, and performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... on its top with a friction striking material which shall, by a pull of the tear strip, be entirely exposed for striking the friction igniter button. The igniter button shall be non-water soluble or be... manner as to provide positive ignition by the friction striker. The igniter button shall be firmly...

  8. Distal Attachment of Flexor Tendon Allograft: A Biomechanical Study of Different Reconstruction Techniques in Human Cadaver Hands

    PubMed Central

    Wei, Zhuang; Thoreson, Andrew R.; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2014-01-01

    We compared the mechanical force of tendon-to-bone repair techniques for flexor tendon reconstruction. Thirty-six flexor digitorum profundus (FDP) tendons were divided into three groups based upon the repair technique: (1) suture/button repair using FDP tendon (Pullout button group), (2) suture bony anchor using FDP tendon (Suture anchor group), and (3) suture/button repair using FDP tendon with its bony attachment preserved (Bony attachment group). The repair failure force and stiffness were measured. The mean load to failure and stiffness in the bony attachment group were significantly higher than that in the pullout button and suture anchor groups. No significant difference was found in failure force and stiffness between the pullout button and suture anchor groups. An intrasynovial flexor tendon graft with its bony attachment has significantly improved tensile properties at the distal repair site when compared with a typical tendon-to-bone attachment with a button or suture anchor. The improvement in the tensile properties at the repair site may facilitate postoperative rehabilitation and reduce the risk of graft rupture. PMID:23754507

  9. Results from a Test Fixture for button BPM Trapped Mode Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Bacha, B.; Blednykh, A.

    2009-05-04

    A variety of measures have been suggested to mitigate the problem of button BPM trapped mode heating. A test fixture, using a combination of commercial-off-the-shelf and custom machined components, was assembled to validate the simulations. We present details of the fixture design, measurement results, and a comparison of the results with the simulations. A brief history of the trapped mode button heating problem and a set of design rules for BPM button optimization are presented elsewhere in these proceedings. Here we present measurements on a test fixture that was assembled to confirm, if possible, a subset of those rules: (1)more » Minimize the trapped mode impedance and the resulting power deposited in this mode by the beam. (2) Maximize the power re-radiated back into the beampipe. (3) Maximize electrical conductivity of the outer circumference of the button and minimize conductivity of the inner circumference of the shell, to shift power deposition from the button to the shell. The problem is then how to extract useful and relevant information from S-parameter measurements of the test fixture.« less

  10. Outcome of locking compression plates in humeral shaft nonunions

    PubMed Central

    Kumar, Malhar N; Ravindranath, V Pratap; Ravishankar, MR

    2013-01-01

    Background: Nonunion of diaphyseal fractures of the humerus are frequently seen in clinical practice (incidence of up to 15% in certain studies) and osteosynthesis using dynamic compression plates, intra medullary nails and Ilizarov fixators have been reported previously. Locking compression plates (LCP) are useful in the presence of disuse osteoporosis, segmental bone loss and cortical defects that preclude strong fixation. We report a prospective followup study of the outcome of the use of LCP for humeral nonunion following failed internal fixation in which implants other than LCP had been used. Materials and Methods: Twenty four patients with nonunion of humeral shaft fractures following failed internal fixation were included in the study. The mean followup period was 3.4 years (range: 2.4 to 5.7 years) and the minimum followup period was 2 years. Mean age of the patients was 41.04 years (range: 24 to 57 years). All 24 patients underwent osteosynthesis using LCP and autologous bone grafting (cortico-cancellous iliac crest graft combined with or without fibular strut graft). Main outcome measurements included radiographic assessment of fracture union and pre and postoperative functional evaluation using the modified Constant and Murley scoring system. Results: 23 out of 24 fractures united following osteosynthesis. Average time to union was 16 weeks (range: 10 to 28 weeks). Complications included delayed union (n = 2), transient radial nerve palsy (n = 2) and persistent nonunion (n = 1). Functional evaluation using the Constant and Murley score showed excellent results in 11, good in 10, fair in two and poor outcome in one patient. Conclusions: Locking compression plating and cancellous bone grafting is a reliable option for achieving union in humeral diaphyseal nonunion with failed previous internal fixation and results in good functional outcome in patients with higher physiological demands. PMID:23682176

  11. Facilitating text reading in posterior cortical atrophy.

    PubMed

    Yong, Keir X X; Rajdev, Kishan; Shakespeare, Timothy J; Leff, Alexander P; Crutch, Sebastian J

    2015-07-28

    We report (1) the quantitative investigation of text reading in posterior cortical atrophy (PCA), and (2) the effects of 2 novel software-based reading aids that result in dramatic improvements in the reading ability of patients with PCA. Reading performance, eye movements, and fixations were assessed in patients with PCA and typical Alzheimer disease and in healthy controls (experiment 1). Two reading aids (single- and double-word) were evaluated based on the notion that reducing the spatial and oculomotor demands of text reading might support reading in PCA (experiment 2). Mean reading accuracy in patients with PCA was significantly worse (57%) compared with both patients with typical Alzheimer disease (98%) and healthy controls (99%); spatial aspects of passages were the primary determinants of text reading ability in PCA. Both aids led to considerable gains in reading accuracy (PCA mean reading accuracy: single-word reading aid = 96%; individual patient improvement range: 6%-270%) and self-rated measures of reading. Data suggest a greater efficiency of fixations and eye movements under the single-word reading aid in patients with PCA. These findings demonstrate how neurologic characterization of a neurodegenerative syndrome (PCA) and detailed cognitive analysis of an important everyday skill (reading) can combine to yield aids capable of supporting important everyday functional abilities. This study provides Class III evidence that for patients with PCA, 2 software-based reading aids (single-word and double-word) improve reading accuracy. © 2015 American Academy of Neurology.

  12. Facilitating text reading in posterior cortical atrophy

    PubMed Central

    Rajdev, Kishan; Shakespeare, Timothy J.; Leff, Alexander P.; Crutch, Sebastian J.

    2015-01-01

    Objective: We report (1) the quantitative investigation of text reading in posterior cortical atrophy (PCA), and (2) the effects of 2 novel software-based reading aids that result in dramatic improvements in the reading ability of patients with PCA. Methods: Reading performance, eye movements, and fixations were assessed in patients with PCA and typical Alzheimer disease and in healthy controls (experiment 1). Two reading aids (single- and double-word) were evaluated based on the notion that reducing the spatial and oculomotor demands of text reading might support reading in PCA (experiment 2). Results: Mean reading accuracy in patients with PCA was significantly worse (57%) compared with both patients with typical Alzheimer disease (98%) and healthy controls (99%); spatial aspects of passages were the primary determinants of text reading ability in PCA. Both aids led to considerable gains in reading accuracy (PCA mean reading accuracy: single-word reading aid = 96%; individual patient improvement range: 6%–270%) and self-rated measures of reading. Data suggest a greater efficiency of fixations and eye movements under the single-word reading aid in patients with PCA. Conclusions: These findings demonstrate how neurologic characterization of a neurodegenerative syndrome (PCA) and detailed cognitive analysis of an important everyday skill (reading) can combine to yield aids capable of supporting important everyday functional abilities. Classification of evidence: This study provides Class III evidence that for patients with PCA, 2 software-based reading aids (single-word and double-word) improve reading accuracy. PMID:26138948

  13. Repair of Acute Superficial Deltoid Complex Avulsion During Ankle Fracture Fixation in National Football League Players.

    PubMed

    Hsu, Andrew R; Lareau, Craig R; Anderson, Robert B

    2015-11-01

    Infolding and retraction of an avulsed deltoid complex after ankle fracture can be a source of persistent increased medial clear space, malreduction, and postoperative pain and medial instability. The purpose of this descriptive case series was to analyze the preliminary outcomes of acute superficial deltoid complex avulsion repair during ankle fracture fixation in a cohort of National Football League (NFL) players. We found that there is often complete avulsion of the superficial deltoid complex off the proximal aspect of the medial malleolus during high-energy ankle fractures in athletes. Between 2004 and 2014, the cases of 14 NFL players who underwent ankle fracture fixation with open deltoid complex repair were reviewed. Patients with chronic deltoid ligament injuries or ankle fractures more than 2 months old were excluded. Average age for all patients was 25 years and body mass index 34.4. Player positions included 1 wide receiver, 1 tight end, 1 safety, 1 running back, 1 linebacker, and 9 offensive linemen. Average time from injury to surgery was 7.5 days. Surgical treatment for all patients consisted of ankle arthroscopy and debridement, followed by fibula fixation with plate and screws, syndesmotic fixation with suture-button devices, and open deltoid complex repair with suture anchors. Patient demographics were recorded with position played, time from injury to surgery, games played before and after surgery, ability to return to play, and postoperative complications. Return to play was defined as the ability to successfully participate in at least 1 full regular-season NFL game after surgery. All NFL players were able to return to running and cutting maneuvers by 6 months after surgery. There were no significant differences in playing experience before surgery versus after surgery. Average playing experience before surgery was 3.3 seasons, 39 games played, and 22 games started. Average playing experience after surgery was 1.6 seasons, 16 games played, and 15 games started. Return to play was 86% for all players. There were no intraoperative or postoperative complications noted, and no players had clinical evidence of medial pain or instability at final follow-up with radiographic maintenance of anatomic mortise alignment. Superficial deltoid complex avulsion during high-energy ankle fractures in athletes is a distinct injury pattern that should be recognized and may benefit from primary open repair. The majority of NFL players treated surgically for this injury pattern are able to return to play after surgery with no reported complications or persistent medial ankle pain or instability. Level IV, retrospective case series. © The Author(s) 2015.

  14. Switch from intracellular to intercellular invasion during water stress-tolerant legume nodulation

    PubMed Central

    Goormachtig, Sofie; Capoen, Ward; James, Euan K.; Holsters, Marcelle

    2004-01-01

    Rhizobia colonize their legume hosts by different modes of entry while initiating symbiotic nitrogen fixation. Most legumes are invaded via growing root hairs by the root hair-curl mechanism, which involves epidermal cell responses. However, invasion of a number of tropical legumes happens through fissures at lateral root bases by cortical, intercellular crack entry. In the semiaquatic Sesbania rostrata, the bacteria entered via root hair curls under nonflooding conditions. Upon flooding, root hair growth was prevented, invasion on accessible root hairs was inhibited, and intercellular invasion was recruited. The plant hormone ethylene was involved in these processes. The occurrence of both invasion pathways on the same host plant enabled a comparison to be made of the structural requirements for the perception of nodulation factors, which were more stringent for the epidermal root hair invasion than for the cortical intercellular invasion at lateral root bases. PMID:15079070

  15. Nasal foreign bodies in children: should they have a plain radiograph in the accident and emergency?

    PubMed

    Glynn, Fergal; Amin, Mohamed; Kinsella, John

    2008-04-01

    To determine the proportion of children with nasal foreign bodies who had button batteries as the foreign body. To describe the clinical care and outcome of those children with a button battery foreign body. A retrospective review of all children presenting to the accident and emergency room with a nasal foreign body or unilateral nasal discharge during a 6-month period was assessed. Forty-four children were included. The most common object found was a plastic bead (27%), followed by foam, paper, or tissue fragments (23%); food matter represented 15%. A button battery was found in 3 patients (7%); other foreign bodies included stones, buttons, crayons, erasers, and a pellet. Thiry-six (82%) had their foreign body removed without anesthetic and 8 (18%) required a general anesthetic. All 3 children with a button battery went undiagnosed until examination in the operating theater. Because there was no previous indication of the presence of a button battery in the 3 children, the removal of the foreign body under general anesthesia was scheduled for the following day. The removal of the button batteries would have been expedited had a plain radiograph been obtained, possibly resulting in less morbidity for our patients. We recommend a plain radiograph in all children presenting with a nonvisible foreign body or unilateral nasal discharge.

  16. Repair of long-bone fractures in cats and small dogs with the Unilock mandible locking plate system.

    PubMed

    Voss, K; Kull, M; Hässig, M; Montavon, P

    2009-01-01

    To retrospectively evaluate stabilisation of long-bone fractures in cats and small dogs using the Unilock system. Medical histories and radiographs of consecutive patients with long-bone fractures stabilised with the Unilock system were reviewed. Cases with follow-up radiographs taken at least four weeks postoperatively were included. Signalment of the patient, fracture localisation and type, primary fracture repair or revision surgery, single or double plating, and complications for each patient were noted. Additionally, implant size, number of screws, number of cortices engaged with screws, and number of empty holes across the fracture were evaluated in fractures where a single plate had been applied. Eighteen humeral, 18 radial, 20 femoral, and 10 tibial fractures were treated. The Unilock system was used for primary repair in 44 fractures and for revision surgery in 22 fractures. Two plates were applied in 17 fractures, and a single plate was applied in 49 fractures. Follow-up radiographs were taken four to 109 weeks postoperatively. Complications were seen in 12 animals and 13 fractures (19.7%). Fixation failure occurred in seven fractures (10.6%). Cases with a single plate that suffered fixation failure had thinner screws in relation to bone diameter than cases with double plates, and more screws in a main fragment than those without fixation failure. The Unilock system is a suitable implant for fracture fixation of long bones in cats and small dogs.

  17. The Blue Button Project: Engaging Patients in Healthcare by a Click of a Button.

    PubMed

    Mohsen, Mona Omar; Aziz, Hassan A

    2015-01-01

    The Blue Button project has become a way for many Americans to download their health records by just a click in any way that suits them, such as in print, on a thumb drive, or on their mobile devices and smartphones. Several organizations have developed and applied Blue Buttons on their websites to allow beneficiaries to securely access and view personal medical information and claims. The purpose of this literature review is to highlight the significance of the Blue Button project in the field of health information management. Findings suggest that the project could empower and engage consumers and patients in a healthcare system by allowing access to medical records, thereby promoting better management and overall improvement of their healthcare. To date, the project has gained wide support from insurers, technology companies, and health providers despite the challenges of standardization and interoperability.

  18. BPM Button Optimization to Minimize Distortion Due to Trapped Mode Heating

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cameron,P.; Blednyk, A.; Kosciuk, B.

    2009-05-04

    The outer circumference of a BPM button and the inner circumference of the button housing comprise a transmission line. This transmission line typically presents an impedance of a few tens of ohms to the beam, and couples very weakly to the 50 ohm coaxial transmission line that comprises the signal path out of the button. The modes which are consequently excited and trapped often have quality factors of several hundred, permitting resonant excitation by the beam. The thermal distortion resulting from trapped mode heating is potentially problematic for achieving the high precision beam position measurements needed to provide the sub-micronmore » beam position stability required by light source users. We present a button design that has been optimized via material selection and component geometry to minimize both the trapped mode heating and the resulting thermal distortion.« less

  19. The Blue Button Project: Engaging Patients in Healthcare by a Click of a Button

    PubMed Central

    Mohsen, Mona Omar; Aziz, Hassan A.

    2015-01-01

    The Blue Button project has become a way for many Americans to download their health records by just a click in any way that suits them, such as in print, on a thumb drive, or on their mobile devices and smartphones. Several organizations have developed and applied Blue Buttons on their websites to allow beneficiaries to securely access and view personal medical information and claims. The purpose of this literature review is to highlight the significance of the Blue Button project in the field of health information management. Findings suggest that the project could empower and engage consumers and patients in a healthcare system by allowing access to medical records, thereby promoting better management and overall improvement of their healthcare. To date, the project has gained wide support from insurers, technology companies, and health providers despite the challenges of standardization and interoperability. PMID:26755898

  20. The Role of Microfilaments in Early Meiotic Maturation of Mouse Oocytes

    NASA Astrophysics Data System (ADS)

    Calarco, Patricia G.

    2005-04-01

    Mouse oocyte microfilaments (MF) were perturbed by depolymerization (cytochalasin B) or stabilization (jasplakinolide) and correlated meiotic defects examined by confocal microscopy. MF, microtubules, and mitochondria were vitally stained; centrosomes ([gamma]-tubulin), after fixation. MF depolymerization by cytochalasin in culture medium did not affect central migration of centrosomes, mitochondria, or nuclear breakdown (GVBD); some MF signal was localized around the germinal vesicle (GV). In maturation-blocking medium (containing IBMX), central movement was curtailed and cortical MF aggregations made the plasma membrane wavy. Occasional long MF suggested that not all MF were depolymerized. MF stabilization by jasplakinolide led to MF aggregations throughout the cytoplasm. GVBD occurred (unless IBMX was present) but no spindle formed. Over time, most oocytes constricted creating a dumbbell shape with MF concentrated under one-half of the oocyte cortex and on either side of the constriction. In IBMX medium, the MF-containing half of the dumbbell over time sequestered the GV, MF, mitochondria, and one to two large cortical centrosomes; the non-MF half appeared empty. Cumulus processes contacted the oocyte surface (detected by microtubule content) and mirrored MF distribution. Results demonstrated that MF play an essential role in meiosis, primarily through cortically mediated events, including centrosome localization, spindle (or GV) movement to the periphery, activation of (polar body) constriction, and establishment of oocyte polarity. The presence of a cortical “organizing pole” is hypothesized.

  1. Esophageal button battery ingestions: decreasing time to operative intervention by level I trauma activation.

    PubMed

    Russell, Robert T; Griffin, Russell L; Weinstein, Elizabeth; Billmire, Deborah F

    2014-09-01

    The incidence of button battery ingestions is increasing and injury due to esophageal impaction begins within minutes of exposure. We changed our management algorithm for suspected button battery ingestions with intent to reduce time to evaluation and operative removal. A retrospective study was performed to identify and evaluate time to treatment and outcome for all esophageal button battery ingestions presenting to a major children's hospital emergency room from February 1, 2010 through February 1, 2012. During the first year, standard emergency room triage (ST) was used. During the second year, the triage protocol was changed and Trauma I triage (TT) was used. 24 children had suspected button battery ingestions with 11 having esophageal impaction. One esophageal impaction was due to 2 stacked coins. Time from arrival in emergency room to battery removal was 183minutes in ST group (n=4) and 33minutes in TT group (n=7) (p=0.04). One patient in ST developed a tracheoesophageal fistula. There were no complications in the TT group. The use of Trauma 1 activations for suspected button battery ingestions has led to more expedient evaluation and shortened time to removal of impacted esophageal batteries. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Evaluation of Cognitive Function of Children with Developmental Disabilities by means of Button-Press Task

    NASA Astrophysics Data System (ADS)

    Nakazono, Shogo; Kobori, Satoshi

    The button-press task means that the subject observes a moving target and presses a button to stop it when the target enters a specified area on a computer display. Subjects perform normal task, suppressed task and delayed task. In the suppressed task, the moving target disappears at some point during the trial. In the delayed task, there is some lag time between the time of pressing button and of stopping target. In these tasks, subjects estimate the movement of the target, and press the button considering his/her own reaction time. In our previous study, we showed that cognitive and motor function was able to be evaluated by these tasks. In this study, we examined error data of children with developmental disabilities to evaluate the cognitive function, and investigated the learning processes. Moreover, we discussed the developmental stages by comparing the children with disabilities to normal control children, and we clarified the behavior characteristics of children with developmental disabilities. Asa result, it was shown that our evaluation method and system for the button-press task were effective to evaluate cognitive ability of children with developmental disabilities.

  3. Method for fusing bone

    DOEpatents

    Mourant, J.R.; Anderson, G.D.; Bigio, I.J.; Johnson, T.M.

    1996-03-12

    The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  4. P300 Source Localization Contrasts in Body-Focused Repetitive Behaviors and Tic Disorders

    PubMed Central

    Sauvé, Geneviève; O’Connor, Kieron P.; Blanchet, Pierre J.

    2017-01-01

    Tic disorders (TD) and body-focused repetitive behaviors (BFRB) have similar phenotypes that can be challenging to distinguish in clinical settings. Both disorders show high rates of comorbid psychiatric conditions, dysfunctional basal ganglia activity, atypical cortical functioning in the prefrontal and motor cortical regions, and cognitive deficits. Clinicians frequently confound the two disorders and it is important to find reliable objective methods to discriminate TD and BFRB. Neuropsychological tests and event-related potential (ERP) studies have yielded inconsistent results regarding a possible context updating deficit in TD and BFRB patients. However, most previous studies did not control for the presence of comorbid psychiatric condition and medication status, which might have confounded the findings reported to date. Hence, we aimed to investigate the psychophysiology of working memory using ERP in carefully screened TD and BFRB patients excluding those with psychiatric comorbidity and those taking psychoactive medication. The current study compared 12 TD patients, 12 BRFB patients, and 15 healthy control participants using a motor oddball task (button press). The P300 component was analyzed as an index of working memory functioning. Results showed that BFRB patients had decreased P300 oddball effect amplitudes over the right hemisphere compared to the TD and control groups. Clinical groups presented different scalp distributions compared to controls, which could represent a potential endophenotype candidate of BFRB and TD. PMID:28671557

  5. Toward Patient Specific Long Lasting Metallic Implants for Mandibular Segmental Defects

    NASA Astrophysics Data System (ADS)

    Shayesteh Moghaddam, Narges

    Mandibular defects may result from tumor resection, trauma, or inflammation. The goals of mandibular reconstruction surgeries are to restore mandible function and aesthetics. To this end, surgeons use a combination of bone grafts and metallic implants. These implants have drastically different mechanical properties than the surrounding bone. As a result, the stress distribution in the mandible changes after surgery. The long-term abnormal stress/strain distribution may lead to either graft failure due to bone resorption as a result of stress shielding, or hardware failure due to stress concentrations. During the healing period of six to nine months it is important that complete immobilization, bringing mandibular micro-motion down to the level of 200-500 mum during chewing, is achieved. After this period it is desired that bone undergo normal stress for long-term success of the treatment. Although current high stiffness fixation hardware accomplishes this immobilization during the healing period, the hardware continues to alter the normal stress-strain trajectory seen during chewing once the engrafted bone heals. Over the long-term, the immobilized and stress-shielded engrafted bone tends to resorb. On the other hand, hardware fracturing or/and screw loosening is observed as the stress is concentrated at certain locations on the hardware. Equally as important is the permanent loss of chewing power due to the altered stress-strain relationships. The first stage of this research is to study the problems encountered following a mandibular segmental defect reconstructive surgery. To this end, we constructed a finite element model of a healthy mandible, which includes cortical and cancellous bone, teeth (enamel and dentin components), and the periodontal ligament. Using this model, we studied a healthy adult mandible under maximum molar bite force for stress, strain, displacement, and reaction force distribution. For mandibular segmental defect reconstruction the current standard of care consists of the use of Surgical Grade 5 titanium also known as Ti-6Al-4V hardware and either a single or double fibula barrel vascularized bone graft. We expanded our model to simulate the effects of this surgery. The expanded model includes both single and double barrel fibular bone graft repair of a right M1-M3 containing section of the mandible, Ti-6Al-4V fixation hardware and screws. We found that the stiffness mismatch between the fixation hardware and the bone causes stress shielding on the host mandible and the bone graft, and stress concentration at the fixation hardware and screws. The simulations results show that while a double-barrel graft is preferred, in the long-term it does not create the optimal outcome due to the abnormal stress pattern. To improve the long-term outcome with metallic implants it is essential to recreate the normal stress pattern. To achieve this outcome we investigated the use of porous nitinol as a substitute for the currently used titanium hardware. While NiTi already has a lower stiffness than titanium, it is possible to add porosity to further reduce the stiffness to be closer to that of cortical bone. The ultimate goal is to create fixation hardware that has sufficient stiffness for immobilization while recreating the normal stress pattern in the bone. Using a finite element model of devices fabricated from Surgical Grade 5 titanium and NiTi, we have found that stiffness-tuned NiTi hardware with conventional geometries should result in recreation of normal stress-strain trajectories and better treatment outcome. Finally, to further improve the outcome, we suggest the use of a two-stage mechanism Bone Bandaid which supports both the immobilization/healing and regenerative phases of mandibular segmental defect treatment. This device is made of two materials. The stiff Ti-6Al-4V portion provides the support during the healing period and is disengaged afterwards. The second material is a NiTi wire-frame to facilitate normal stress distribution after the initial healing period. The titanium part of this fixation hardware is released following radiological verification that the surgical osteotomies have healed. The release procedure is performed under local anesthetic via a microsurgical tool. With the titanium fixation hardware no longer functional, the NiTi webbing would act as a superstructure, like a skin, to the underlying grafted cortical bone. This device facilitates stress transduction through the normal stress-strain trajectories, allows restoration of power, drives cortical bone remodeling and strengthening, provides long-term strength, and a good bone bed for dental implants. If bone chips are used, instead of single or double bone graft, the webbing is more likely to support the bone chips while they are being incorporated with the mandible. We have performed computer simulation to investigate the two stages of the operation of the device. Our FEA results indicate that the Bone Bandaid supports both the immobilization needed during healing and the distribution of stress through the engrafted bone once it has healed. (Abstract shortened by ProQuest.).

  6. Modified rush pin technique for two- or three-part proximal humeral fractures.

    PubMed

    Mallick, A; Hearth, M; Singh, S; Pandey, R

    2008-12-01

    To report the outcomes of modified Rush pin fixation for proximal humeral fractures. 42 men and 20 women aged 19 to 94 (mean, 64) years with 2- or 3-part proximal humeral fractures underwent reduction and fixation using the modified Rush pin technique. 11 patients died from reasons unrelated to the surgery. Of 40 (out of 51) patients completing a subjective functional assessment using an Oxford Shoulder Questionnaire, 28 (70%) had 2-part and 10 (25%) had 3-part displaced fractures, and the remaining 2 (5%) had fracture-dislocations (one being 2-part and one 3-part). 25 (63%) patients were very satisfied (including one with a 3-part fracture after 6 months of rehabilitation), 7 (17%) were moderately satisfied, and 8 (20%) were not satisfied. There were 8 complications, including pin cut-out from the proximal fragment (n=2), proximal pin migration (n=2), distal pin migration (n=1), cortical perforation during surgery (n=1), mild ulnar nerve symptoms (n=1). No patients had non-union, myositis ossificans, avascular necrosis of the humeral head, or axillary nerve injury. The modified Rush pin fixation minimises tissue dissection; the implants are cheap and readily available; and the technical expertise is easily learnt. This technique is a suitable alternative of fixing proximal humeral fractures, especially in the elderly.

  7. Neural mechanisms of attention become more specialised during infancy: Insights from combined eye tracking and EEG.

    PubMed

    Kulke, Louisa; Atkinson, Janette; Braddick, Oliver

    2017-03-01

    The Fixation Shift Paradigm (FSP) measures infants' ability to shift gaze from a central fixation stimulus to a peripheral target (e.g. Hood & Atkinson, 1993: Infant Behavior and Development, 16(4), 405-422). Cortical maturation has been suggested as crucial for the developing ability to shift attention. This study investigated the development of neural mechanisms by combining EEG with simultaneous eye tracking during FSP testing, in typically developing infants aged between 1 and 8 months. The most prominent neural response was a frontal positivity which occurred only in the hemisphere contralateral to the target in the youngest infants but became more ipsilateral with age. This changing lateralisation was associated with improving ability to shift attention (decreasing saccade latencies and fewer 'sticky fixations'-failures to disengage attention from the central target). These findings suggest that the lateralisation of neural responses develops during infancy, possibly due to developing intracortical connections, allowing infants to shift attention more efficiently. Successful use of combined simultaneous remote eye tracking and EEG to measure infant attention shifts. Neural responses involved in attention shifts change in the first year of life. The lateralisation of EEG responses changes with age in the first year of life. Frontal cortex is involved in attention shifts from around 2 months of age. © 2016 Wiley Periodicals, Inc.

  8. Formaldehyde fixation is detrimental to actin cables in glucose-depleted S. cerevisiae cells

    PubMed Central

    Vasicova, Pavla; Rinnerthaler, Mark; Haskova, Danusa; Novakova, Lenka; Malcova, Ivana; Breitenbach, Michael; Hasek, Jiri

    2016-01-01

    Actin filaments form cortical patches and emanating cables in fermenting cells of Saccharomyces cerevisiae. This pattern has been shown to be depolarized in glucose-depleted cells after formaldehyde fixation and staining with rhodamine-tagged phalloidin. Loss of actin cables in mother cells was remarkable. Here we extend our knowledge on actin in live glucose-depleted cells co-expressing the marker of actin patches (Abp1-RFP) with the marker of actin cables (Abp140-GFP). Glucose depletion resulted in appearance of actin patches also in mother cells. However, even after 80 min of glucose deprivation these cells showed a clear network of actin cables labeled with Abp140-GFP in contrast to previously published data. In live cells with a mitochondrial dysfunction (rho0 cells), glucose depletion resulted in almost immediate appearance of Abp140-GFP foci partially overlapping with Abp1-RFP patches in mother cells. Residual actin cables were clustered in patch-associated bundles. A similar overlapping “patchy” pattern of both actin markers was observed upon treatment of glucose-deprived rho+ cells with FCCP (the inhibitor of oxidative phosphorylation) and upon treatment with formaldehyde. While the formaldehyde-targeted process stays unknown, our results indicate that published data on yeast actin cytoskeleton obtained from glucose-depleted cells after fixation should be considered with caution. PMID:28357356

  9. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    PubMed

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (p<0.001), but the distance of that was so small (mean, 0.47 mm) that it did not cause any problem clinically. Although further improvement might be needed, such as screw specification, the closed reduction and internal fixation method has many advantages: short operative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  10. Low-Cost Avoidance Behaviors are Resistant to Fear Extinction in Humans

    PubMed Central

    Vervliet, Bram; Indekeu, Ellen

    2015-01-01

    Elevated levels of fear and avoidance are core symptoms across the anxiety disorders. It has long been known that fear serves to motivate avoidance. Consequently, fear extinction has been the primary focus in pre-clinical anxiety research for decades, under the implicit assumption that removing the motivator of avoidance (fear) would automatically mitigate the avoidance behaviors as well. Although this assumption has intuitive appeal, it has received little scientific scrutiny. The scarce evidence from animal studies is mixed, while the assumption remains untested in humans. The current study applied an avoidance conditioning protocol in humans to investigate the effects of fear extinction on the persistence of low-cost avoidance. Online danger-safety ratings and skin conductance responses documented the dynamics of conditioned fear across avoidance and extinction phases. Anxiety- and avoidance-related questionnaires explored individual differences in rates of avoidance. Participants first learned to click a button during a predictive danger signal, in order to cancel an upcoming aversive electrical shock (avoidance conditioning). Next, fear extinction was induced by presenting the signal in the absence of shocks while button-clicks were prevented (by removing the button in Experiment 1, or by instructing not to click the button in Experiment 2). Most importantly, post-extinction availability of the button caused a significant return of avoidant button-clicks. In addition, trait-anxiety levels correlated positively with rates of avoidance during a predictive safety signal, and with the rate of pre- to post-extinction decrease during this signal. Fear measures gradually decreased during avoidance conditioning, as participants learned that button-clicks effectively canceled the shock. Preventing button-clicks elicited a sharp increase in fear, which subsequently extinguished. Fear remained low during avoidance testing, but danger-safety ratings increased again when button-clicks were subsequently prevented. Together, these results show that low-cost avoidance behaviors can persist following fear extinction and induce increased threat appraisal. On the other hand, fear extinction did reduce augmented rates of unnecessary avoidance during safety in trait-anxious individuals, and instruction-based response prevention was more effective than removal of response cues. More research is needed to characterize the conditions under which fear extinction might mitigate avoidance. PMID:26733837

  11. Modeling the impact of pedestrian behavior diversity on traffic dynamics at a crosswalk with push button

    NASA Astrophysics Data System (ADS)

    Xie, Dong-Fan; Zhao, Xiao-Mei; Li, Xin-Gang; Zhu, Tai-Lang

    2016-01-01

    Crosswalk with push button is prevalent in lots of cities for the purpose of promoting the efficiency of the crosswalk, and thus the delays of both vehicles and pedestrians can be reduced. This strategy has been confirmed to be effective in several developed countries. However, it is a pity that application of push button is aborted in some cities in China. In this work, diverse behaviors of vehicles and pedestrians are analyzed and discussed. Then, a microscopic model is developed by incorporating the interaction between vehicles and pedestrians. Numerical simulations are performed to reveal the characteristics of traffic flow and the efficiency of the signal control strategy. Also, the impacts of risker proportion and button reaction time, as well as the impacts of various behaviors as mass behavior, the patience of pedestrian and push button habit are investigated. It is expected that the results will be helpful to the strategy design of a signalized crosswalk in such developing countries as China.

  12. Management of nasal septal perforation using silicone nasal septal button

    PubMed Central

    Mullace, M; Gorini, E; Sbrocca, M; Artesi, L; Mevio, N

    2006-01-01

    Summary Nasal septal perforation may present with various symptoms: epistaxis, crusting, secondary infection, whistling and nasal obstruction. Perforation may be treated by conservative pharmacological treatment or closed by surgical approach. A useful alternative is mechanical obturation, achieved inserting a prosthesis. The present report refers to a study on 15 patients (10 male, 5 female, mean age 38.5 years) treated by insertion of a one-piece or two-piece silicone septal button (Xomed). In the follow-up period, insertion of the nasal button reduced epistaxis, eliminated whistling during inspiration, and reduced nasal obstruction and crusting around the margin of the perforation. Contraindications are presence of acute infection with osteitis, chronic septal disease (Wegener), neoplasia and extremely large perforations. The latest buttons appear to be superior to the conventional type on account of plasticity and adaptability which offer greater conformity to the septum. This study also reveals that the new septal button is well tolerated by patients. PMID:18236638

  13. Delayed system response times affect immediate physiology and the dynamics of subsequent button press behavior.

    PubMed

    Kohrs, Christin; Hrabal, David; Angenstein, Nicole; Brechmann, André

    2014-11-01

    System response time research is an important issue in human-computer interactions. Experience with technical devices and general rules of human-human interactions determine the user's expectation, and any delay in system response time may lead to immediate physiological, emotional, and behavioral consequences. We investigated such effects on a trial-by-trial basis during a human-computer interaction by measuring changes in skin conductance (SC), heart rate (HR), and the dynamics of button press responses. We found an increase in SC and a deceleration of HR for all three delayed system response times (0.5, 1, 2 s). Moreover, the data on button press dynamics was highly informative since subjects repeated a button press with more force in response to delayed system response times. Furthermore, the button press dynamics could distinguish between correct and incorrect decisions and may thus even be used to infer the uncertainty of a user's decision. Copyright © 2014 Society for Psychophysiological Research.

  14. Transition Metal Transport in Plants and Associated Endosymbionts: Arbuscular Mycorrhizal Fungi and Rhizobia

    PubMed Central

    González-Guerrero, Manuel; Escudero, Viviana; Saéz, Ángela; Tejada-Jiménez, Manuel

    2016-01-01

    Transition metals such as iron, copper, zinc, or molybdenum are essential nutrients for plants. These elements are involved in almost every biological process, including photosynthesis, tolerance to biotic and abiotic stress, or symbiotic nitrogen fixation. However, plants often grow in soils with limiting metallic oligonutrient bioavailability. Consequently, to ensure the proper metal levels, plants have developed a complex metal uptake and distribution system, that not only involves the plant itself, but also its associated microorganisms. These microorganisms can simply increase metal solubility in soils and making them more accessible to the host plant, as well as induce the plant metal deficiency response, or directly deliver transition elements to cortical cells. Other, instead of providing metals, can act as metal sinks, such as endosymbiotic rhizobia in legume nodules that requires relatively large amounts to carry out nitrogen fixation. In this review, we propose to do an overview of metal transport mechanisms in the plant–microbe system, emphasizing the role of arbuscular mycorrhizal fungi and endosymbiotic rhizobia. PMID:27524990

  15. Prevention of longitudinal crack propagation around a femoral prosthesis: a study of cerclage wire fixation.

    PubMed

    Difazio, F A; Incavo, S J; Howe, J D

    1993-09-01

    This study examined the effect of single versus triple-wrap cerclage fixation techniques in preventing propagation of a longitudinal fracture around a cementless femoral prosthesis. A proximal filling femoral component was implanted in 14 matched pairs of fresh-frozen bovine femora, following placement of a 45-mm longitudinal crack in the anteromedial cortical wall of the proximal femur. In one group of seven pairs, a single cerclage wire was applied to one specimen of each pair. A triple-wrap of a single cerclage wire was similarly placed in one specimen of each of the other seven pairs. All specimens were axially loaded on a materials testing system machine and the force required to propagate the fracture of the proximal femur was recorded. A triple-wrap cerclage technique required a significant increase in the force to propagate a proximal femur fracture around a non-cemented prosthesis when compared to a single cerclage wire. Copyright © 1993. Published by Elsevier Ltd.

  16. [Arthrodesis without bone fusion with an intramedullary modular nail for revision of infected total knee arthroplasty].

    PubMed

    Miralles-Muñoz, F A; Lizaur-Utrilla, A; Manrique-Lipa, C; López-Prats, F A

    2014-01-01

    To evaluate the outcome of knee fixation without bone fusion using an intramedullary modular nail and interposed cement. Retrospective study of 29 infected total knee arthroplasties with prospective data collection and a mean follow-up of 4.2 years (3-5). Complications included 2 recurrent infections, 1 peri-implant fracture, and 1 cortical erosion due to the tip of the femoral component. All of these were revised with successful results. The mean limb length discrepancy was 0.8 cm, with 24<1cm. Twenty-five patients reported no pain. The mean WOMAC-pain was 86.9, WOMAC-function 56.4, SF12-physical 45.1, and SF12-mental 53.7. Four patients needed a walking frame, and only two were dependent for daily activities. The Endo-Model Link nail is an effective method for knee fixation that restores the anatomical alignment of the limb with adequate leg length. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  17. How to Use This Website | USDA Plant Hardiness Zone Map

    Science.gov Websites

    , regional or national plant hardiness zone maps in three different resolutions using the following steps. To default printing menu option or button. Viewing the Map - Open Full Map Button c. Save Full Map Button can copy the e-mail address and paste it into a different e-mail client (e.g., Google Gmail, Yahoo

  18. Modification of Shirt Buttons for Retrospective Radiation Dosimetry after a Radiological Event

    PubMed Central

    Marino, Stephen A.; Johnson, Gary W.; Schiff, Peter B.; Brenner, David J.

    2010-01-01

    Preliminary results are presented for a personal radiation dosimeter in the form of a clothing button to provide gamma-ray dose estimation for clinically significant external radiation exposures to the general public due to a radiological incident, such as a Radiological Dispersal Device. Rods of thermoluminescent material (LiF:Mg,Ti and LiF:Mg,Cu,P) were encapsulated in plastic “buttons”, attached to shirts, and subjected to three cycles of home or commercial laundering or dry cleaning, including ironing or pressing. The buttons were subsequently exposed to doses of 137Cs gamma rays ranging from 0.75 to 8.2 Gy. The rods were removed from the buttons and their light output compared to their responses when bare or to the responses of a set of calibration rods of the same type and from the same manufacturer. In all three of the comparisons for LiF:Mg,Ti rods the relative responses of the rods in buttons changed by 2-6% relative to the same rods before cleaning. In both comparisons for LiF:Mg,Cu,P rods, the response of laundered rods was 1-3% lower than for the same rods before cleaning. Both these materials are potential candidates for button dosimeters. PMID:21451325

  19. Esophageal button battery ingestion in children.

    PubMed

    Şencan, Arzu; Genişol, İncinur; Hoşgör, Münevver

    2017-07-01

    Button battery lodged in the esophagus carries a high risk of morbidity and mortality. The purpose of this study was to present cases of patients with esophageal button battery ingestion treated at our clinic and to emphasize the importance of early diagnosis and treatment. Records of patients admitted to our hospital for foreign body ingestion between January 2010 and May 2015 were retrospectively reviewed. Cases with button battery lodged in the esophagus were included in the study. Patient data regarding age, sex, length of time after ingestion until admission, presenting clinical symptoms, type and localization of the battery, management, and prognosis were analyzed. Among 1891 foreign body ingestions, 71 were localized in the esophagus, and 8 of those (11.2%) were cases of button battery ingestion. Mean age was 1.7 years. Admission was within 6 hours of ingestion in 5 cases, after 24 hours had elapsed in 2, and 1 month after ingestion in 1 case. All patients but 1 knew the history of ingestion. Prompt endoscopic removal was performed for all patients. Three patients developed esophageal stricture, which responded to dilatation. Early recognition and timely endoscopic removal is mandatory in esophageal button battery ingestion. It should be suspected in the differential diagnosis of patients with persistent respiratory and gastrointestinal symptoms.

  20. Thermocron iButton and iBBat temperature dataloggers emit ultrasound.

    PubMed

    Willis, Craig K R; Jameson, Joel W; Faure, Paul A; Boyles, Justin G; Brack, Virgil; Cervone, Tom H

    2009-10-01

    Thermocron iButton dataloggers are widely used to measure thermal microclimates experienced by wild animals. The iBBat is a smaller version of the datalogger, also commercially available, that is used to measure animal skin or core body temperatures when attached externally or surgically implanted. Field observations of bats roosting under a bridge suggested that bats avoided locations with iButtons. A heterodyne bat detector revealed that the dataloggers emitted ultrasound which was detectable from a distance of up to 30 cm. We therefore recorded and quantified the acoustic properties [carrier frequency (Hz) and root mean square sound pressure level (dB SPL)] of iButton and iBBat dataloggers. All units emitted a 32.9 kHz pure tone that was readily picked up with a time expansion bat detector at a distance of 1 cm, and most were detected at a distance of 15 cm. The maximum amplitude of iButton dataloggers was 46.5 dB SPL at 1.0 cm-a level within the range of auditory sensitivity for most small mammals. Wrapping iButtons in plastic insulation severely attenuated the amplitude of ultrasound. Although there was a statistically significant reduction in rates of warming and cooling with insulation, this effect was small and we suggest that insulation may be a viable solution to eliminate unwanted ultrasonic noise in instances when small delays in thermal response dynamics are not a concern. We recommend behavioural studies to assess if the electronic signals emitted by iButtons are disturbing to small mammals.

  1. Learning processes underlying avoidance of negative outcomes.

    PubMed

    Andreatta, Marta; Michelmann, Sebastian; Pauli, Paul; Hewig, Johannes

    2017-04-01

    Successful avoidance of a threatening event may negatively reinforce the behavior due to activation of brain structures involved in reward processing. Here, we further investigated the learning-related properties of avoidance using feedback-related negativity (FRN). The FRN is modulated by violations of an intended outcome (prediction error, PE), that is, the bigger the difference between intended and actual outcome, the larger the FRN amplitude is. Twenty-eight participants underwent an operant conditioning paradigm, in which a behavior (button press) allowed them to avoid a painful electric shock. During two learning blocks, participants could avoid an electric shock in 80% of the trials by pressing one button (avoidance button), or by not pressing another button (punishment button). After learning, participants underwent two test blocks, which were identical to the learning ones except that no shocks were delivered. Participants pressed the avoidance button more often than the punishment button. Importantly, response frequency increased throughout the learning blocks but it did not decrease during the test blocks, indicating impaired extinction and/or habit formation. In line with a PE account, FRN amplitude to negative feedback after correct responses (i.e., unexpected punishment) was significantly larger than to positive feedback (i.e., expected omission of punishment), and it increased throughout the blocks. Highly anxious individuals showed equal FRN amplitudes to negative and positive feedback, suggesting impaired discrimination. These results confirm the role of negative reinforcement in motivating behavior and learning, and reveal important differences between high and low anxious individuals in the processing of prediction errors. © 2017 Society for Psychophysiological Research.

  2. Soft and wet actuator developed with responsible high-strength gels

    NASA Astrophysics Data System (ADS)

    Harada, S.; Hidema, R.; Furukawa, H.

    2012-04-01

    Novel high-strength gels, named double network gels (DN gels), show a smart response to altering external electric field. It was reported that a plate shape of the DN gel bends toward a positive electrode direction when a static (DC) electric field is applied. Based on this previous result, it has been tried to develop a novel soft and wet actuator, which will be used as an automatically bulging button for cellar phones, or similar small devices. First, a bending experiment of a hung plate-shape DN gel was done, and its electric field response was confirmed. Second, the response of a lying plate-shape DN gels was confirmed in order to check the bulging phenomena. The edge of three plate-shape gels that was arranged radially on a plane surface was lifted 2mm by applying DC 8V. This system is a first step to make a gels button. However the critical problem is that electrolysis occurs simultaneously under electric field. Then, the water sweep out from gels, and gels is shrinking; They cause the separation between aluminum foil working as electrode and gels. That is why, a flexible electrode should be made by gels completely attached to the gels. As a third step, a push button is tried to make by a shape memory gels (SMG). The Young's modulus of the SMG is dramatically changed by temperature. This change in the modulus is applied to control the input-acceptable state and input-not-acceptable states of the button. A novel push button is proposed as a trial, and its user-friendliness is checked by changing the size of the button. The button is deformed by pushing and is back to original shape due to the property of shape memory. We believe the mechanism of this button will be applied to develop new devices especially for visually impaired persons.

  3. Serious complications after button battery ingestion in children.

    PubMed

    Krom, Hilde; Visser, Margot; Hulst, Jessie M; Wolters, Victorien M; Van den Neucker, Anita M; de Meij, Tim; van der Doef, Hubert P J; Norbruis, Obbe F; Benninga, Marc A; Smit, Margot J M; Kindermann, Angelika

    2018-07-01

    Serious and fatal complications after button battery ingestion are increasing worldwide. The aim of this study is to describe serious complications after battery ingestion in children in the Netherlands.All pediatric gastroenterologists in the Netherlands performing upper endoscopies were asked to report all serious complications after battery ingestion in children (0-18 years) between 2008 and 2016 retrospectively.Sixteen serious complications were reported: death after massive bleeding through esophageal-aortal fistula (n = 1), esophageal-tracheal fistula (n = 5), stenosis after (suspected) perforation and mediastinitis (n = 5), (suspected) perforation and mediastinitis (n = 3), vocal cord paralysis (n = 1), and required reintubation for dyspnea and stridor (n = 1). The median time interval between ingestion and presentation was 5 (IQR 2-258) h. All children were ≤ 5 (median 1.4; IQR 0.9-2.1) years. Vomiting (31.3%), swallowing/feeding problems (31.3%), and fever (31.3%) were the most common presenting symptoms; however, 18.8% of the patients were asymptomatic (n = 1 missing). All batteries were button batteries (75% ≥ 20 mm; 18.8% < 20 mm; n = 1 missing). The batteries were removed by esophagogastroduodenoscopy (50%) and rigid endoscopy (37.5%) or surgically (12.5%). Sixteen serious complications occurred after small and large button batteries ingestion between 2008 and 2016 in both symptomatic and asymptomatic children in the Netherlands. Therefore, immediate intervention after (suspected) button battery ingestion is required. What is Known: • Button battery ingestion may result in serious and fatal complications. • Serious and fatal complications after button battery ingestion are increasing worldwide. What is New: • Sixteen serious complications after button battery ingestion occurred during 2008-2016 in children in the Netherlands. • Serious complications were also caused by small batteries (< 20 mm) in the Netherlands and also occurred in asymptomatic Dutch children.

  4. Orienting movements in area 9 identified by long-train ICMS.

    PubMed

    Lanzilotto, M; Perciavalle, V; Lucchetti, C

    2015-03-01

    The effect of intracortical microstimulation has been studied in several cortical areas from motor to sensory areas. The frontal pole has received particular attention, and several microstimulation studies have been conducted in the frontal eye field, supplementary eye field, and the premotor ear-eye field, but no microstimulation studies concerning area 9 are currently available in the literature. In the present study, to fill up this gap, electrical microstimulation was applied to area 9 in two macaque monkeys using long-train pulses of 500-700-800 and 1,000 ms, during two different experimental conditions: a spontaneous condition, while the animals were not actively fixating on a visual target, and during a visual fixation task. In these experiments, we identified backward ear movements, goal-directed eye movements, and the development of head forces. Kinematic parameters for ear and eye movements overlapped in the spontaneous condition, but they were different during the visual fixation task. In this condition, ear and eye kinematics have an opposite behavior: movement amplitude, duration, and maximal and mean velocities increase during a visual fixation task for the ear, while they decrease for the eye. Therefore, a top-down visual attention engagement could modify the kinematic parameters for these two effectors. Stimulation with the longest train durations, i.e., 800/1,000 ms, evokes not only the highest eye amplitude, but also a significant development of head forces. In this research article, we propose a new vision of the frontal oculomotor fields, speculating a role for area 9 in the control of goal-directed orienting behaviors and gaze shift control.

  5. Spatial mapping of humeral head bone density.

    PubMed

    Alidousti, Hamidreza; Giles, Joshua W; Emery, Roger J H; Jeffers, Jonathan

    2017-09-01

    Short-stem humeral replacements achieve fixation by anchoring to the metaphyseal trabecular bone. Fixing the implant in high-density bone can provide strong fixation and reduce the risk of loosening. However, there is a lack of data mapping the bone density distribution in the proximal humerus. The aim of the study was to investigate the bone density in proximal humerus. Eight computed tomography scans of healthy cadaveric humeri were used to map bone density distribution in the humeral head. The proximal humeral head was divided into 12 slices parallel to the humeral anatomic neck. Each slice was then divided into 4 concentric circles. The slices below the anatomic neck, where short-stem implants have their fixation features, were further divided into radial sectors. The average bone density for each of these regions was calculated, and regions of interest were compared using a repeated-measures analysis of variance with significance set at P < .05. Average apparent bone density was found to decrease from proximal to distal regions, with the majority of higher bone density proximal to the anatomic neck of the humerus (P < .05). Below the anatomic neck, bone density increases from central to peripheral regions, where cortical bone eventually occupies the space (P < .05). In distal slices below the anatomic neck, a higher bone density distribution in the medial calcar region was also observed. This study indicates that it is advantageous with respect to implant fixation to preserve some bone above the anatomic neck and epiphyseal plate and to use the denser bone at the periphery. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  6. The cortical basis of true memory and false memory for motion.

    PubMed

    Karanian, Jessica M; Slotnick, Scott D

    2014-02-01

    Behavioral evidence indicates that false memory, like true memory, can be rich in sensory detail. By contrast, there is fMRI evidence that true memory for visual information produces greater activity in earlier visual regions than false memory, which suggests true memory is associated with greater sensory detail. However, false memory in previous fMRI paradigms may have lacked sufficient sensory detail to recruit earlier visual processing regions. To investigate this possibility in the present fMRI study, we employed a paradigm that produced feature-specific false memory with a high degree of visual detail. During the encoding phase, moving or stationary abstract shapes were presented to the left or right of fixation. During the retrieval phase, shapes from encoding were presented at fixation and participants classified each item as previously "moving" or "stationary" within each visual field. Consistent with previous fMRI findings, true memory but not false memory for motion activated motion processing region MT+, while both true memory and false memory activated later cortical processing regions. In addition, false memory but not true memory for motion activated language processing regions. The present findings indicate that true memory activates earlier visual regions to a greater degree than false memory, even under conditions of detailed retrieval. Thus, the dissociation between previous behavioral findings and fMRI findings do not appear to be task dependent. Future work will be needed to assess whether the same pattern of true memory and false memory activity is observed for different sensory modalities. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Connections between intraparietal sulcus and a sensorimotor network underpin sustained tactile attention.

    PubMed

    Goltz, Dominique; Gundlach, Christopher; Nierhaus, Till; Villringer, Arno; Müller, Matthias; Pleger, Burkhard

    2015-05-20

    Previous studies on sustained tactile attention draw conclusions about underlying cortical networks by averaging over experimental conditions without considering attentional variance in single trials. This may have formed an imprecise picture of brain processes underpinning sustained tactile attention. In the present study, we simultaneously recorded EEG-fMRI and used modulations of steady-state somatosensory evoked potentials (SSSEPs) as a measure of attentional trial-by-trial variability. Therefore, frequency-tagged streams of vibrotactile stimulations were simultaneously presented to both index fingers. Human participants were cued to sustain attention to either the left or right finger stimulation and to press a button whenever they perceived a target pulse embedded in the to-be-attended stream. In-line with previous studies, a classical general linear model (GLM) analysis based on cued attention conditions revealed increased activity mainly in somatosensory and cerebellar regions. Yet, parametric modeling of the BOLD response using simultaneously recorded SSSEPs as a marker of attentional trial-by-trial variability quarried the intraparietal sulcus (IPS). The IPS in turn showed enhanced functional connectivity to a modality-unspecific attention network. However, this was only revealed on the basis of cued attention conditions in the classical GLM. By considering attentional variability as captured by SSSEPs, the IPS showed increased connectivity to a sensorimotor network, underpinning attentional selection processes between competing tactile stimuli and action choices (press a button or not). Thus, the current findings highlight the potential value by considering attentional variations in single trials and extend previous knowledge on the role of the IPS in tactile attention. Copyright © 2015 the authors 0270-6474/15/357938-12$15.00/0.

  8. A PC parallel port button box provides millisecond response time accuracy under Linux.

    PubMed

    Stewart, Neil

    2006-02-01

    For psychologists, it is sometimes necessary to measure people's reaction times to the nearest millisecond. This article describes how to use the PC parallel port to receive signals from a button box to achieve millisecond response time accuracy. The workings of the parallel port, the corresponding port addresses, and a simple Linux program for controlling the port are described. A test of the speed and reliability of button box signal detection is reported. If the reader is moderately familiar with Linux, this article should provide sufficient instruction for him or her to build and test his or her own parallel port button box. This article also describes how the parallel port could be used to control an external apparatus.

  9. Improved selection of cortical ovarian strips for autotransplantation of ovarian tissue using full-field optical coherence tomography (FFOCT)

    NASA Astrophysics Data System (ADS)

    Stegehuis, Paulien L.; Peters, Inge T. A.; Eggermont, Jeroen; Kuppen, Peter J. K.; Trimbos, J. Baptist; Lelieveldt, Boudewijn P. F.; van de Velde, Cornelis J. H.; Bosse, Tjalling; Dijkstra, Jouke; Vahrmeijer, Alexander L.

    2016-02-01

    Premature ovarian failure is a major concern in women of reproductive age who undergo gonadotoxic cancer treatment. Autotransplantation of frozen-thawed cortical ovarian tissue allows the immediate start of cancer treatment, but risks reintroduction of cancer. Current tumor detection methods compromise the ovarian tissue's viability and can therefore only be used to exclude the presence of metastases in the cortical ovarian strips that are not transplanted. A non-invasive method is needed that can be used to exclude metastases in the actual ovarian autografts without affecting the tissue's viability. In this study we applied FFOCT - a non-fixative technique that uses white light interferometry to make highresolution images (1μm isotropic) of fresh tissue - to study healthy and malignant ovarian tissue. We created an image atlas of healthy ovarian tissues from premenopausal patients and ovarian tissues with breast cancer metastases. To get the best possible match between hematoxylin-and-eosin stained slides and FFOCT images formalinfixed paraffin-embedded tissue samples were deparaffinized and FFOCT images were acquired within a few minutes. FFOCT images were compared with histology images. All normal structures such as follicles in all phases, inclusion cysts, blood vessels, corpora lutea, and corpora albicantia were clearly recognizable. Ovarian metastases could be well distinguished from normal ovarian tissue. FFOCT is a promising technique in the field of fertility preservation: metastases can be detected and additionally cortical ovarian strips can be selected on the basis of high follicle density.

  10. A Jungle in There: Bacteria in Belly Buttons are Highly Diverse, but Predictable

    PubMed Central

    Hulcr, Jiri; Latimer, Andrew M.; Henley, Jessica B.; Rountree, Nina R.; Fierer, Noah; Lucky, Andrea; Lowman, Margaret D.; Dunn, Robert R.

    2012-01-01

    The belly button is one of the habitats closest to us, and yet it remains relatively unexplored. We analyzed bacteria and arachaea from the belly buttons of humans from two different populations sampled within a nation-wide citizen science project. We examined bacterial and archaeal phylotypes present and their diversity using multiplex pyrosequencing of 16S rDNA libraries. We then tested the oligarchy hypothesis borrowed from tropical macroecology, namely that the frequency of phylotypes in one sample of humans predicts its frequency in another independent sample. We also tested the predictions that frequent phylotypes (the oligarchs) tend to be common when present, and tend to be more phylogenetically clustered than rare phylotypes. Once rarefied to four hundred reads per sample, bacterial communities from belly buttons proved to be at least as diverse as communities known from other skin studies (on average 67 bacterial phylotypes per belly button). However, the belly button communities were strongly dominated by a few taxa: only 6 phylotypes occurred on >80% humans. While these frequent bacterial phylotypes (the archaea were all rare) are a tiny part of the total diversity of bacteria in human navels (<0.3% of phylotypes), they constitute a major portion of individual reads (∼1/3), and are predictable among independent samples of humans, in terms of both the occurrence and evolutionary relatedness (more closely related than randomly drawn equal sets of phylotypes). Thus, the hypothesis that “oligarchs” dominate diverse assemblages appears to be supported by human-associated bacteria. Although it remains difficult to predict which species of bacteria might be found on a particular human, predicting which species are most frequent (or rare) seems more straightforward, at least for those species living in belly buttons. PMID:23144827

  11. Response-Related Potentials during Semantic Priming: The Effect of a Speeded Button Response Task on ERPs

    PubMed Central

    van Vliet, Marijn; Manyakov, Nikolay V.; Storms, Gert; Fias, Wim; Wiersema, Jan R.; Van Hulle, Marc M.

    2014-01-01

    This study examines the influence of a button response task on the event-related potential (ERP) in a semantic priming experiment. Of particular interest is the N400 component. In many semantic priming studies, subjects are asked to respond to a stimulus as fast and accurately as possible by pressing a button. Response time (RT) is recorded in parallel with an electroencephalogram (EEG) for ERP analysis. In this case, the response occurs in the time window used for ERP analysis and response-related components may overlap with stimulus-locked ones such as the N400. This has led to a recommendation against such a design, although the issue has not been explored in depth. Since studies keep being published that disregard this issue, a more detailed examination of influence of response-related potentials on the ERP is needed. Two experiments were performed in which subjects pressed one of two buttons with their dominant hand in response to word-pairs with varying association strength (AS), indicating a personal judgement of association between the two words. In the first experiment, subjects were instructed to respond as fast and accurately as possible. In the second experiment, subjects delayed their button response to enforce a one second interval between the onset of the target word and the button response. Results show that in the first experiment a P3 component and motor-related potentials (MRPs) overlap with the N400 component, which can cause a misinterpretation of the latter. In order to study the N400 component, the button response should be delayed to avoid contamination of the ERP with response-related components. PMID:24516556

  12. Comparative assessment of button cells using a normalized index for potential pollution by heavy metals.

    PubMed

    Moreno-Merino, Luis; Jiménez-Hernández, Maria Emilia; de la Losa, Almudena; Huerta-Muñoz, Virginia

    2015-09-01

    Many household batteries worldwide still end up in landfills or are incinerated due to inefficient collection and recycling schemes. Toxic heavy metals from improperly discarded button cells pose a serious risk to human health and the environment, as they can pollute air, soil and water. This paper analyses a series of button cells selected from batteries available on the retail market, and compares their polluting potential. A total of 64 batteries were subjected to chemical analyses of 19 elements - including metals and metalloids - , and energy density measurements. The samples were from four different brands of each of the four most common button cell technologies (alkaline, zinc-air, silver oxide and lithium). An energy-normalized index - the Weighted Potential Pollution Index (WPPI) - was proposed to compare the polluting potential of the different batteries. The higher the battery WPPI score, the greater the content in toxic elements and the lower the energy output. The results of the chemical composition and energy density varied depending on the construction technology of the button cells. However, significant differences in both variables were also found when comparing different brands within the same technology. The differences in WPPI values confirmed the existence of a significant margin to reduce the environmental impact of discarded button cells simply by avoiding the most polluting options. The choice of the battery with the most favourable WPPI produced a reduction in potential pollution of 3-53% for silver oxide batteries, 4-39% for alkaline, 20-28% for zinc-air and 12-26% for lithium. Comparative potential pollution could be assessed when selecting batteries using an energy-normalized index such as WPPI to reduce the environmental impact of improperly disposed button cells. Published by Elsevier B.V.

  13. Exploring Virtual Worlds with Head-Mounted Displays

    DTIC Science & Technology

    1989-02-01

    docking problem is important both to biochemists attempting to understand how proteins and nucleic acids work, and to chemists doing analytic drug design...then depressing the mouse button he is able to manipulate the methotrexate. A. long as the mouse button is depressed the methotrexate will follow the... depressing the mouse button outside of the drug’s "grabbing" volume. In this mode, both molecules move in concert. When the active site is positioned to

  14. The floor effect: impoverished spatial memory for elevator buttons.

    PubMed

    Vendetti, Michael; Castel, Alan D; Holyoak, Keith J

    2013-05-01

    People typically remember objects to which they have frequently been exposed, suggesting that memory is a by-product of perception. However, prior research has shown that people have exceptionally poor memory for the features of some objects (e.g., coins) to which they have been exposed over the course of many years. Here, we examined how people remember the spatial layout of the buttons on a frequently used elevator panel, to determine whether physical interaction (rather than simple exposure) would ensure the incidental encoding of spatial information. Participants who worked in an eight-story office building displayed very poor recall for the elevator panel but above-chance performance on a recognition test. Performance was related to how often and how recently the person had used the elevator. In contrast to their poor memory for the spatial layout of the elevator buttons, most people readily recalled small distinctive graffiti on the elevator walls. In a more implicit test, the majority were able to locate their office floor and the eighth floor button when asked to point toward these buttons when in the actual elevator, with the button labels covered. However, identification was very poor for other floors (including the first floor), suggesting that even frequent interaction with information does not always lead to accurate spatial memory. These findings have implications for understanding the complex relationships among attention, expertise, and memory.

  15. Identifying predictive factors for long-term complications following button battery impactions: A case series and literature review.

    PubMed

    Eliason, Michael J; Melzer, Jonathan M; Winters, Jessica R; Gallagher, Thomas Q

    2016-08-01

    To complement a case series review of button battery impactions managed at our single military tertiary care center with a thorough literature review of laboratory research and clinical cases to develop a protocol to optimize patient care. Specifically, to identify predictive factors of long-term complications which can be used by the pediatric otolaryngologist to guide patient management after button battery impactions. A retrospective review of the Department of Defense's electronic medical record systems was conducted to identify patients with button battery ingestions and then characterize their treatment course. A thorough literature review complemented the lessons learned to identify potentially predictive clinical measures for long-term complications. Eight patients were identified as being treated for button battery impaction in the aerodigestive tract with two sustaining long-term complications. The median age of the patients treated was 33 months old and the median estimated time of impaction in the aerodigestive tract prior to removal was 10.5 h. Time of impaction, anatomic direction of the battery's negative pole, and identifying specific battery parameters were identified as factors that may be employed to predict sequelae. Based on case reviews, advancements in battery manufacturing, and laboratory research, there are distinct clinical factors that should be assessed at the time of initial therapy to guide follow-up management to minimize potential catastrophic sequelae of button battery ingestion. Published by Elsevier Ireland Ltd.

  16. Drying kinetics and characteristics of combined infrared-vacuum drying of button mushroom slices

    NASA Astrophysics Data System (ADS)

    Salehi, Fakhreddin; Kashaninejad, Mahdi; Jafarianlari, Ali

    2017-05-01

    Infrared-vacuum drying characteristics of button mushroom ( Agaricus bisporus) were evaluated in a combined dryer system. The effects of drying parameters, including infrared radiation power (150-375 W), system pressure (5-15 kPa) and time (0-160 min) on the drying kinetics and characteristics of button mushroom slices were investigated. Both the infrared lamp power and vacuum pressure influenced the drying time of button mushroom slices. The rate constants of the nine different kinetic's models for thin layer drying were established by nonlinear regression analysis of the experimental data which were found to be affected mainly by the infrared power level while system pressure had a little effect on the moisture ratios. The regression results showed that the Page model satisfactorily described the drying behavior of button mushroom slices with highest R value and lowest SE values. The effective moisture diffusivity increases as power increases and range between 0.83 and 2.33 × 10-9 m2/s. The rise in infrared power has a negative effect on the ΔE and with increasing in infrared radiation power it was increased.

  17. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation.

    PubMed

    Sugawara, Taku; Higashiyama, Naoki; Kaneyama, Shuichi; Sumi, Masatoshi

    2017-03-15

    Prospective clinical trial of the screw insertion method for posterior C1-C2 fixation utilizing the patient-specific screw guide template technique. To evaluate the efficacy of this method for insertion of C1 lateral mass screws (LMS), C2 pedicle screws (PS), and C2 laminar screws (LS). Posterior C1LMS and C2PS fixation, also known as the Goel-Harms method, can achieve immediate rigid fixation and high fusion rate, but the screw insertion carries the risk of injury to neuronal and vascular structures. Dissection of venous plexus and C2 nerve root to confirm the insertion point of the C1LMS may also cause problems. We have developed an intraoperative screw guiding method using patient-specific laminar templates. Preoperative bone images of computed tomography (CT) were analyzed using three-dimensional (3D)/multiplanar imaging software to plan the trajectories of the screws. Plastic templates with screw guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Surgery was performed using this patient-specific screw guide template system, and placement of the screws was postoperatively evaluated using CT. Twelve patients with C1-C2 instability were treated with a total of 48 screws (24 C1LMS, 20 C2PS, 4 C2LS). Intraoperatively, each template was found to exactly fit and lock on the lamina and screw insertion was completed successfully without dissection of the venous plexus and C2 nerve root. Postoperative CT showed no cortical violation by the screws, and mean deviation of the screws from the planned trajectories was 0.70 ± 0.42 mm. The multistep, patient-specific screw guide template system is useful for intraoperative screw navigation in posterior C1-C2 fixation. This simple and economical method can improve the accuracy of screw insertion, and reduce operation time and radiation exposure of posterior C1-C2 fixation surgery. 3.

  18. Salter-Harris type II metacarpal and metatarsal fracture in three foals. Treatment by minimally-invasive lag screw osteosynthesis combined with external coaptation.

    PubMed

    Klopfenstein Bregger, Micaël D; Fürst, Anton E; Kircher, Patrick R; Kluge, Katharina; Kummer, Martin

    2016-05-18

    To describe minimally-invasive lag screw osteosynthesis combined with external coaptation for the treatment of Salter-Harris type II third metacarpal and third metatarsal bone fractures. Three foals aged two weeks to four months with a Salter-Harris type II third metacarpal or third metatarsal fracture. Surgery was carried out under general anaesthesia in lateral recumbency. After fracture reduction, the metaphyseal fragment was stabilized with two cortical screws placed in lag fashion under fluoroscopic control. A cast was applied for at least two weeks. All foals had a good outcome with complete fracture healing and return to complete soundness without any angular limb deformity. All foals had moderate transient digital hyperextension after cast removal. Internal fixation of Salter-Harris type II third metacarpal or third metatarsal fractures with two cortical screws in lag fashion, combined with external coaptation provided good stabilization and preserved the longitudinal growth potential of the injured physis.

  19. Adaptation to Skew Distortions of Natural Scenes and Retinal Specificity of Its Aftereffects

    PubMed Central

    Habtegiorgis, Selam W.; Rifai, Katharina; Lappe, Markus; Wahl, Siegfried

    2017-01-01

    Image skew is one of the prominent distortions that exist in optical elements, such as in spectacle lenses. The present study evaluates adaptation to image skew in dynamic natural images. Moreover, the cortical levels involved in skew coding were probed using retinal specificity of skew adaptation aftereffects. Left and right skewed natural image sequences were shown to observers as adapting stimuli. The point of subjective equality (PSE), i.e., the skew amplitude in simple geometrical patterns that is perceived to be unskewed, was used to quantify the aftereffect of each adapting skew direction. The PSE, in a two-alternative forced choice paradigm, shifted toward the adapting skew direction. Moreover, significant adaptation aftereffects were obtained not only at adapted, but also at non-adapted retinal locations during fixation. Skew adaptation information was transferred partially to non-adapted retinal locations. Thus, adaptation to skewed natural scenes induces coordinated plasticity in lower and higher cortical areas of the visual pathway. PMID:28751870

  20. Method for fusing bone

    DOEpatents

    Mourant, Judith R.; Anderson, Gerhard D.; Bigio, Irving J.; Johnson, Tamara M.

    1996-01-01

    Method for fusing bone. The present invention is a method for joining hard tissue which includes chemically removing the mineral matrix from a thin layer of the surfaces to be joined, placing the two bones together, and heating the joint using electromagnetic radiation. The goal of the method is not to produce a full-strength weld of, for example, a cortical bone of the tibia, but rather to produce a weld of sufficient strength to hold the bone halves in registration while either external fixative devices are applied to stabilize the bone segments, or normal healing processes restore full strength to the tibia.

  1. Reverse Dynamization: Influence of Fixator Stiffness on the Mode and Efficiency of Large-Bone-Defect Healing at Different Doses of rhBMP-2.

    PubMed

    Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher

    2016-04-20

    Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

  2. Healing at the interface between recipient sites and autologous block bone grafts affixed by either position or lag screw methods: a histomorphometric study in rabbits.

    PubMed

    Caneva, Marco; Botticelli, Daniele; Carneiro Martins, Evandro Neto; Caneva, Martina; Lang, Niklaus P; Xavier, Samuel P

    2017-12-01

    To compare the sequential healing at the interface gap occurring between autologous bone grafts and recipient sites using two types of fixation techniques. Twenty-four adult male New Zealand white rabbits were used. Two bone grafts were collected from the calvaria and secured to the lateral aspect of the angle of mandible in each animal. Cortical perforations at the recipient sites were performed. However, no modifications were applied to the graft for its adaptation to the recipient site. Two types of fixation techniques by position or lag screws were applied. This was done by preparing osteotomy holes smaller or larger than the screw diameter, respectively. The animals were sacrificed after 3, 7, 20, and 40 days. After 3 days, the distance between the graft and the recipient site was similar between the two different fixations. Due to the anatomical shapes of the recipient sites and grafts, the distance between the two parts was lower in the central region (<0.1 mm) compared to the external regions of the graft (0.5-0.6 mm). The first evidence of small amounts of new (woven) bone was seen after 7 days, forming from the parent bone. The percentage increased after 20 and 40 days. After 40 days, the grafts were well incorporated within the recipient sites in both groups without any statistically significant difference. The present study did not show superiority of one method over another. A fixation to a recipient site with perforations may be sufficient for incorporating an autologous bone graft even if its adaptation is not perfect and irrespectively of the fixation method. Distances of approximately half millimeter were bridged with newly formed bone. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Activity of neurons in area 6 of the cat during fixation and eye movements.

    PubMed

    Weyand, T G; Gafka, A C

    1998-01-01

    We studied the visuomotor properties of 645 neurons in area 6 of five cats trained in oculomotor tasks. The area we recorded from corresponds well with territories believed to contain the feline homologue of the frontal eye fields observed in primates. Despite an expectation that cells with pre-saccadic activity would be common, only a small fraction (approximately 5%) of the cells displayed activity that could be linked to subsequent saccadic eye movements. These pre-motor cells appeared to be distributed over a broad region of cortex mixed in with other cell types. As in primates, saccade-related activity tended to occur only during "purposeful" saccades. At least 30% (208/645) of the neurons were visual, with many of these cells possessing huge receptive fields that appeared to include the entire contralateral visual field. Visual responsiveness was generally attenuated by fixation during the oculomotor tasks. Although attentional mechanisms may play a role in this attenuation, this cortical area also exhibits powerful lateral interactions in which spatially displaced visual stimuli suppress each other. Most cells, visually responsive or not, were affected by fixation. Nearly equal proportions of cells showed increases or decreases in activity during fixation. For many of the cells affected by fixation, the source of this modulation appears to reflect cognitive, rather than sensory or motor processes. This included cells that showed anticipatory activity, and cells that responded to the reward only when it was presented in the context of the task. Based on the paucity of pre-saccadic neurons, it would be difficult to conclude that this region of cortex in the cat is homologous to the frontal eye fields of the monkey. However, when considered in the context of differences in the oculomotor habits of these two animals, we believe the homology fits. In addition to pre-motor neurons, the properties of several other cell types found in this area could contribute to the control of gaze.

  4. Button batteries

    MedlinePlus

    Swallowing batteries ... These devices use button batteries: Calculators Cameras Hearing aids Penlights Watches ... If a person puts the battery up their nose and breathes it further in, ... problems Cough Pneumonia (if the battery goes unnoticed) ...

  5. Poisoning: First Aid

    MedlinePlus

    ... Plants Foreign bodies such as watch or button batteries How you treat someone who may have been ... have applied medicated patches or swallowed a button battery. Call 911 or your local emergency number immediately ...

  6. Vascular ring complicates accidental button battery ingestion.

    PubMed

    Mercer, Ronald W; Schwartz, Matthew C; Stephany, Joshua; Donnelly, Lane F; Franciosi, James P; Epelman, Monica

    2015-01-01

    Button battery ingestion can lead to dangerous complications, including vasculoesophageal fistula formation. The presence of a vascular ring may complicate battery ingestion if the battery lodges at the level of the ring and its important vascular structures. We report a 4-year-old boy with trisomy 21 who was diagnosed with a vascular ring at the time of button battery ingestion and died 9 days after presentation due to massive upper gastrointestinal bleeding from esophageal erosion and vasculoesophageal fistula formation. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Graphical User Interface for a Remote Medical Monitoring System: U.S. Army Medic Recommendations

    DTIC Science & Technology

    2009-11-01

    screens. The majority of medics (70%) also wanted a name lis! screen that, when tapped , would go to an individual patient screen. In the name list...button has been pushed. Tapping on thaI button would prompt the user to enter the password. Tapping on the light button would illuminate the screen...a summary of current local weather conditions would be dis- played in the lower ! eft of the screen. In the lower right of this map screen is

  8. Stimulus-response incompatibility activates cortex proximate to three eye fields

    NASA Technical Reports Server (NTRS)

    Merriam, E. P.; Colby, C. L.; Thulborn, K. R.; Luna, B.; Olson, C. R.; Sweeney, J. A.

    2001-01-01

    We used functional magnetic resonance imaging (fMRI) to investigate cortical activation during the performance of three oculomotor tasks that impose increasing levels of cognitive demand. (1) In a visually guided saccade (VGS) task, subjects made saccades to flashed targets. (2) In a compatible task, subjects made leftward and rightward saccades in response to foveal presentation of the uppercase words "LEFT" or "RIGHT." (3) In a mixed task, subjects made rightward saccades in response to the lowercase word "left" and leftward saccades in response to the lowercase word "right" on incompatible trials (60%). The remaining 40% of trials required compatible responses to uppercase words. The VGS and compatible tasks, when compared to fixation, activated the three cortical eye fields: the supplementary eye field (SEF), the frontal eye field (FEF), and the parietal eye field (PEF). The mixed task, when compared to the compatible task, activated three additional cortical regions proximate to the three eye fields: (1) rostral to the SEF in medial frontal cortex; (2) rostral to the FEF in dorsolateral prefrontal cortex (DLPFC); (3) rostral and lateral to the PEF in posterior parietal cortex. These areas may contribute to the suppression of prepotent responses and in holding novel visuomotor associations in working memory. Copyright 2001 Academic Press.

  9. Tibiotalar joint arthrodesis for the treatment of severe ankle joint degeneration secondary to rheumatoid arthritis.

    PubMed

    Caron, M; Kron, E; Saltrick, K R

    1999-04-01

    The technical aspects of fusion of the rheumatoid ankle do not deviate from those in the post-traumatic or osteoarthritic ankle. Screw fixation can usually be achieved, and rarely is fixation failure a problem in rheumatoid ankle arthrodesis. If fixation is difficult because of deformity or bone quality, external fixation or locking intramedullary nails should be used. The placement of cannulated screws and adequacy of screw fixation has not been a problem (Fig. 13). Screw fixation provides compression and prevents rotation. The surgeon, however, needs to be assured that no screws invade the subtalar joint and that all threads are beyond the arthrodesis site. A washer may be necessary for further stability if this screw is not inserted at too great an angle. The authors have found that troughing out of the cortical surface of the tibia with a power bur aids in screw insertion. Not only does the trough act as a countersink, but it also provides a path for screw insertion and prevents palpable screw irritation. Malalignment is unforgiving. The foot must be placed neutral to dorsiflexion and plantarflexion. Equinus positioning places added stress on the tibia and a back-knee gait occurs. Approximately 5 degrees of valgus is recommended, and varus positioning is unforgiving. Internal and external rotation is determined by the position of the contralateral extremity. Nonunion does not seem to be a problem with rigid internal fixation to any greater degree in patients with RA. Despite this, patients may continue to have pain despite solid fusion, which can be caused by incomplete correction of deformity, painful internal fixation, or adjacent joint pathology. Additionally, patients may experience supramalleolar pain above the fusion site consistent with tibial stress fracture, which is more common if the subtalar or midtarsal joint is rigid or if the patient is obese. A rocker sole shoe with impact-absorbing soles used after brief periods of guarded mobilization in a removable walking cast alleviates this stress on the tibia. Neurovascular insult can be avoided with careful dissection direct to bone, incisions placed in nerve-free zones, and avoidance of plunging deep posteriorly-medially and anteriorly when dissecting and resecting surfaces. Arthrodesis of the tibiotalar joint in the patient with RA should be performed to relieve severe pain caused by advanced arthrosis. Achieving a solid arthrodesis does not seem to be a problem and provides the patient with pain relief; however, marked improvement in patient function and level of activity remains limited by the nature of RA and adjacent joint involvement.

  10. Bone density and anisotropy affect periprosthetic cement and bone stresses after anatomical glenoid replacement: A micro finite element analysis.

    PubMed

    Chevalier, Yan; Santos, Inês; Müller, Peter E; Pietschmann, Matthias F

    2016-06-14

    Glenoid loosening is still a main complication for shoulder arthroplasty. We hypothesize that cement and bone stresses potentially leading to fixation failure are related not only to glenohumeral conformity, fixation design or eccentric loading, but also to bone volume fraction, cortical thickness and degree of anisotropy in the glenoid. In this study, periprosthetic bone and cement stresses were computed with micro finite element models of the replaced glenoid depicting realistic bone microstructure. These models were used to quantify potential effects of bone microstructural parameters under loading conditions simulating different levels of glenohumeral conformity and eccentric loading simulating glenohumeral instability. Results show that peak cement stresses were achieved near the cement-bone interface in all loading schemes. Higher stresses within trabecular bone tissue and cement mantle were obtained within specimens of lower bone volume fraction and in regions of low anisotropy, increasing with decreasing glenohumeral conformity and reaching their maxima below the keeled design when the load is shifted superiorly. Our analyses confirm the combined influences of eccentric load shifts with reduced bone volume fraction and anisotropy on increasing periprosthetic stresses. They finally suggest that improving fixation of glenoid replacements must reduce internal cement and bone tissue stresses, in particular in glenoids of low bone density and heterogeneity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Is the Sensorimotor Cortex Relevant for Speech Perception and Understanding? An Integrative Review

    PubMed Central

    Schomers, Malte R.; Pulvermüller, Friedemann

    2016-01-01

    In the neuroscience of language, phonemes are frequently described as multimodal units whose neuronal representations are distributed across perisylvian cortical regions, including auditory and sensorimotor areas. A different position views phonemes primarily as acoustic entities with posterior temporal localization, which are functionally independent from frontoparietal articulatory programs. To address this current controversy, we here discuss experimental results from functional magnetic resonance imaging (fMRI) as well as transcranial magnetic stimulation (TMS) studies. On first glance, a mixed picture emerges, with earlier research documenting neurofunctional distinctions between phonemes in both temporal and frontoparietal sensorimotor systems, but some recent work seemingly failing to replicate the latter. Detailed analysis of methodological differences between studies reveals that the way experiments are set up explains whether sensorimotor cortex maps phonological information during speech perception or not. In particular, acoustic noise during the experiment and ‘motor noise’ caused by button press tasks work against the frontoparietal manifestation of phonemes. We highlight recent studies using sparse imaging and passive speech perception tasks along with multivariate pattern analysis (MVPA) and especially representational similarity analysis (RSA), which succeeded in separating acoustic-phonological from general-acoustic processes and in mapping specific phonological information on temporal and frontoparietal regions. The question about a causal role of sensorimotor cortex on speech perception and understanding is addressed by reviewing recent TMS studies. We conclude that frontoparietal cortices, including ventral motor and somatosensory areas, reflect phonological information during speech perception and exert a causal influence on language understanding. PMID:27708566

  12. Cortical sources of visual evoked potentials during consciousness of executive processes.

    PubMed

    Babiloni, Claudio; Vecchio, Fabrizio; Iacoboni, Marco; Buffo, Paola; Eusebi, Fabrizio; Rossini, Paolo Maria

    2009-03-01

    What is the timing of cortical activation related to consciousness of visuo-spatial executive functions? Electroencephalographic data (128 channels) were recorded in 13 adults. Cue stimulus briefly appeared on right or left (equal probability) monitor side for a period, inducing about 50% of recognitions. It was then masked and followed (2 s) by a central visual go stimulus. Left (right) mouse button had to be clicked after right (left) cue stimulus. This "inverted" response indexed executive processes. Afterward, subjects said "seen" if they had detected the cue stimulus or "not seen" when it was missed. Sources of event-related potentials (ERPs) were estimated by LORETA software. The inverted responses were about 95% in seen trials and about 60% in not seen trials. Cue stimulus evoked frontal-parietooccipital potentials, having the same peak latencies in the seen and not seen data. Maximal difference in amplitude of the seen and not seen ERPs was detected at about +300-ms post-stimulus (P3). P3 sources were higher in amplitude in the seen than not seen trials in dorsolateral prefrontal, premotor and parietooccipital areas. This was true in dorsolateral prefrontal and premotor cortex even when percentage of the inverted responses and reaction time were paired in the seen and not seen trials. These results suggest that, in normal subjects, the primary consciousness enhances the efficacy of visuo-spatial executive processes and is sub-served by a late (100- to 400-ms post-stimulus) enhancement of the neural synchronization in frontal areas.

  13. Oculometric variations during mind wandering

    PubMed Central

    Grandchamp, Romain; Braboszcz, Claire; Delorme, Arnaud

    2014-01-01

    A significant body of literature supports the contention that pupil size varies depending on cognitive load, affective state, and level of drowsiness. Here we assessed whether oculometric measures such as gaze position, blink frequency and pupil size were correlated with the occurrence and time course of self-reported mind-wandering episodes. We recorded the pupil size of two subjects engaged in a monotonous breath counting task while keeping their eyes on a fixation cross. This task is conducive to producing mind-wandering episodes. Each subject performed ten 20-min sessions, for total duration of about 4 h. Subjects were instructed to report spontaneous mind-wandering episodes by pressing a button when they lost count of their breath. After each button press, subjects filled in a short questionnaire describing the characteristics of their mind-wandering episode. We observed larger pupil size during the breath-focusing period compared to the mind-wandering period (p < 0.01 for both subjects). Our findings contradict previous research showing a higher baseline pupil size during mind wandering episodes in visual tasks. We discuss possible explanations for this discrepancy. We also analyzed nine other oculometric measures including blink rate, blink duration and gaze position. We built a support vector machine (SVM) classifier and showed that mean pupil size was the most reliable predictor of mind wandering in both subjects. The classification accuracy of mind wandering data segments vs. breath-focusing data segments was 81% for the first subject and 77% for the second subject. Additionally, we analyzed oculometric measures in light of the phenomenological data collected in the questionnaires. We showed that how well subjects remembered their thoughts while mind wandering was positively correlated with pupil size (subject 1, p < 0.001; subject 2, p < 0.05). Feelings of well being were also positively correlated with pupil size (subject 1, p < 0.001; subject 2, p < 0.001). Our results suggest that oculometric data could be used as a neurocognitive marker of mind-wandering episodes. PMID:24575056

  14. High current capacity electrical connector

    DOEpatents

    Bettis, Edward S.; Watts, Harry L.

    1976-01-13

    An electrical connector is provided for coupling high current capacity electrical conductors such as copper busses or the like. The connector is arranged in a "sandwiched" configuration in which a conductor plate contacts the busses along major surfaces thereof clamped between two stainless steel backing plates. The conductor plate is provided with a plurality of contact buttons affixed therein in a spaced array such that the caps of the buttons extend above the conductor plate surface to contact the busses. When clamping bolts provided through openings in the sandwiched arrangement are tightened, Belleville springs provided under the rim of each button cap are compressed and resiliently force the caps into contact with the busses' contacting surfaces to maintain a predetermined electrical contact area provided by the button cap tops. The contact area does not change with changing thermal or mechanical stresses applied to the coupled conductors.

  15. An EOG-Based Human-Machine Interface for Wheelchair Control.

    PubMed

    Huang, Qiyun; He, Shenghong; Wang, Qihong; Gu, Zhenghui; Peng, Nengneng; Li, Kai; Zhang, Yuandong; Shao, Ming; Li, Yuanqing

    2017-07-27

    Non-manual human-machine interfaces (HMIs) have been studied for wheelchair control with the aim of helping severely paralyzed individuals regain some mobility. The challenge is to rapidly, accurately and sufficiently produce control commands, such as left and right turns, forward and backward motions, acceleration, deceleration, and stopping. In this paper, a novel electrooculogram (EOG)-based HMI is proposed for wheelchair control. Thirteen flashing buttons are presented in the graphical user interface (GUI), and each of the buttons corresponds to a command. These buttons flash on a one-by-one manner in a pre-defined sequence. The user can select a button by blinking in sync with its flashes. The algorithm detects the eye blinks from a channel of vertical EOG data and determines the user's target button based on the synchronization between the detected blinks and the button's flashes. For healthy subjects/patients with spinal cord injuries (SCIs), the proposed HMI achieved an average accuracy of 96.7%/91.7% and a response time of 3.53 s/3.67 s with 0 false positive rates (FPRs). Using only one channel of vertical EOG signals associated with eye blinks, the proposed HMI can accurately provide sufficient commands with a satisfactory response time. The proposed HMI provides a novel non-manual approach for severely paralyzed individuals to control a wheelchair. Compared with a newly established EOG-based HMI, the proposed HMI can generate more commands with higher accuracy, lower FPR and fewer electrodes.

  16. Isolating Discriminant Neural Activity in the Presence of Eye Movements and Concurrent Task Demands

    PubMed Central

    Touryan, Jon; Lawhern, Vernon J.; Connolly, Patrick M.; Bigdely-Shamlo, Nima; Ries, Anthony J.

    2017-01-01

    A growing number of studies use the combination of eye-tracking and electroencephalographic (EEG) measures to explore the neural processes that underlie visual perception. In these studies, fixation-related potentials (FRPs) are commonly used to quantify early and late stages of visual processing that follow the onset of each fixation. However, FRPs reflect a mixture of bottom-up (sensory-driven) and top-down (goal-directed) processes, in addition to eye movement artifacts and unrelated neural activity. At present there is little consensus on how to separate this evoked response into its constituent elements. In this study we sought to isolate the neural sources of target detection in the presence of eye movements and over a range of concurrent task demands. Here, participants were asked to identify visual targets (Ts) amongst a grid of distractor stimuli (Ls), while simultaneously performing an auditory N-back task. To identify the discriminant activity, we used independent components analysis (ICA) for the separation of EEG into neural and non-neural sources. We then further separated the neural sources, using a modified measure-projection approach, into six regions of interest (ROIs): occipital, fusiform, temporal, parietal, cingulate, and frontal cortices. Using activity from these ROIs, we identified target from non-target fixations in all participants at a level similar to other state-of-the-art classification techniques. Importantly, we isolated the time course and spectral features of this discriminant activity in each ROI. In addition, we were able to quantify the effect of cognitive load on both fixation-locked potential and classification performance across regions. Together, our results show the utility of a measure-projection approach for separating task-relevant neural activity into meaningful ROIs within more complex contexts that include eye movements. PMID:28736519

  17. A rabbit model of implant-related osteomyelitis inoculated with biofilm after open femoral fracture

    PubMed Central

    Zhang, Xiang; Ma, Yun-Fei; Wang, Lei; Jiang, Nan; Qin, Cheng-He; Hu, Yan-Jun; Yu, Bin

    2017-01-01

    Currently, animal models used in research on implant-associated osteomyelitis primarily use intramedullary fixation and initial inoculum of planktonic bacterial cells. However, these techniques have certain limitations, including lack of rotational stability and instable inoculation. To improve these models, the present study aimed to establish a novel rabbit model of implant-associated osteomyelitis using biofilm as the initial inoculum following plate fixation of the femoral fracture. A total of 24 New Zealand White rabbits were randomly divided into two equal groups. Osteotomy was performed at the right femoral shaft using a wire saw following fixation with a 5-hole stainless steel plate. The plates were not colonized with bacteria in group 1, but colonized with a biofilm of Staphylococcus aureus (American Type Culture Collection, 25923) in group 2. All the rabbits were sacrificed after 21 days for clinical, X-ray, micro-computed tomography and histological assessments of the severity of osteomyelitis. Scanning electron microscopy and confocal laser scanning microscopy were used for biofilm assessment. In group 2, pus formation, periosteal reaction, cortical destruction and absorption were observed in all the rabbits and biofilm formation was observed on all the plates. However, no pus formation was observed except for a slight inflammatory response and all the plates appeared clean without infection in group 1. The differences between the two groups were statistically significant regarding histologic scores and semi-quantification of the bacteria on the plates (P<0.001). In the present study, a novel rabbit model of infection following internal plate fixation of open fracture was successfully established, providing a novel tool for the study of implant-associated osteomyelitis. PMID:29201204

  18. Reverse Dynamization

    PubMed Central

    Glatt, Vaida; Bartnikowski, Nicole; Quirk, Nicholas; Schuetz, Michael; Evans, Christopher

    2016-01-01

    Background: Reverse dynamization is a technology for enhancing the healing of osseous defects. With use of an external fixator, the axial stiffness across the defect is initially set low and subsequently increased. The purpose of the study described in this paper was to explore the efficacy of reverse dynamization under different conditions. Methods: Rat femoral defects were stabilized with external fixators that allowed the stiffness to be modulated on living animals. Recombinant human bone morphogenetic protein-2 (rhBMP-2) was implanted into the defects on a collagen sponge. Following a dose-response experiment, 5.5 μg of rhBMP-2 was placed into the defect under conditions of very low (25.4-N/mm), low (114-N/mm), medium (185-N/mm), or high (254-N/mm) stiffness. Reverse dynamization was evaluated with 2 different starting stiffnesses: low (114 N/mm) and very low (25.4 N/mm). In both cases, high stiffness (254 N/mm) was imposed after 2 weeks. Healing was assessed with radiographs, micro-computed tomography (μCT), histological analysis, and mechanical testing. Results: In the absence of dynamization, the medium-stiffness fixators provided the best healing. Reverse dynamization starting with very low stiffness was detrimental to healing. However, with low initial stiffness, reverse dynamization considerably improved healing with minimal residual cartilage, enhanced cortication, increased mechanical strength, and smaller callus. Histological analysis suggested that, in all cases, healing provoked by rhBMP-2 occurred by endochondral ossification. Conclusions: These data confirm the potential utility of reverse dynamization as a way of improving bone healing but indicate that the stiffness parameters need to be selected carefully. Clinical Relevance: Reverse dynamization may reduce the amount of rhBMP-2 needed to induce healing of recalcitrant osseous lesions, reduce the time to union, and decrease the need for prolonged external fixation. PMID:27098327

  19. Effect of pore size on bone ingrowth into porous titanium implants fabricated by additive manufacturing: An in vivo experiment.

    PubMed

    Taniguchi, Naoya; Fujibayashi, Shunsuke; Takemoto, Mitsuru; Sasaki, Kiyoyuki; Otsuki, Bungo; Nakamura, Takashi; Matsushita, Tomiharu; Kokubo, Tadashi; Matsuda, Shuichi

    2016-02-01

    Selective laser melting (SLM) is an additive manufacturing technique with the ability to produce metallic scaffolds with accurately controlled pore size, porosity, and interconnectivity for orthopedic applications. However, the optimal pore structure of porous titanium manufactured by SLM remains unclear. In this study, we evaluated the effect of pore size with constant porosity on in vivo bone ingrowth in rabbits into porous titanium implants manufactured by SLM. Three porous titanium implants (with an intended porosity of 65% and pore sizes of 300, 600, and 900μm, designated the P300, P600, and P900 implants, respectively) were manufactured by SLM. A diamond lattice was adapted as the basic structure. Their porous structures were evaluated and verified using microfocus X-ray computed tomography. Their bone-implant fixation ability was evaluated by their implantation as porous-surfaced titanium plates into the cortical bone of the rabbit tibia. Bone ingrowth was evaluated by their implantation as cylindrical porous titanium implants into the cancellous bone of the rabbit femur for 2, 4, and 8weeks. The average pore sizes of the P300, P600, and P900 implants were 309, 632, and 956μm, respectively. The P600 implant demonstrated a significantly higher fixation ability at 2weeks than the other implants. After 4weeks, all models had sufficiently high fixation ability in a detaching test. Bone ingrowth into the P300 implant was lower than into the other implants at 4weeks. Because of its appropriate mechanical strength, high fixation ability, and rapid bone ingrowth, our results indicate that the pore structure of the P600 implant is a suitable porous structure for orthopedic implants manufactured by SLM. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Radial and tibial fracture repair with external skeletal fixation. Effects of fracture type, reduction, and complications on healing.

    PubMed

    Johnson, A L; Kneller, S K; Weigel, R M

    1989-01-01

    Twenty-eight consecutive fractures of the canine radius and tibia were treated with external skeletal fixation as the primary method of stabilization. The time of fixation removal (T1) and the time to unsupported weight-bearing (T2) were correlated with: (1) bone involved; (2) communication of the fracture with the external environment; (3) severity of the fracture; (4) proximity of the fracture to the nutrient artery; (5) method of reduction; (6) diaphyseal displacement after reduction; and (7) gap between cortical fragments after reduction. The Kruskal-Wallis one-way analysis of variance was used to test the correlation with p less than .05 set as the criterion for significance. The median T1 was 10 weeks and the median T2 was 11 weeks. None of the variables correlated significantly with either of the healing times; however, there was a strong trend toward longer healing times associated with open fractures and shorter healing times associated with closed reduction. Periosteal and endosteal callus uniting the fragments were observed radiographically in comminuted fractures, with primary bone union observed in six fractures in which anatomic reduction was achieved. Complications observed in the treatment of these fractures included: bone lysis around pins (27 fractures), pin track drainage (27 fractures), pin track hemorrhage (1 fracture), periosteal reaction around pins (27 fractures), radiographic signs consistent with osteomyelitis (12 fractures), degenerative joint disease (2 dogs), and nonunion (1 fracture). Valgus or rotational malalignment resulted in 16 malunions of fractures. One external fixation device was replaced and four loose pins were removed before the fractures healed. One dog was treated with antibiotics during the postoperative period because clinical signs of osteomyelitis appeared.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Novel method to avoid the open-sky condition in penetrating keratoplasty: covered cornea technique.

    PubMed

    Arslan, Osman S; Unal, Mustafa; Arici, Ceyhun; Cicik, Erdoğan; Mangan, Serhat; Atalay, Eray

    2014-09-01

    The aim of this study was to present a novel technique to avoid the open-sky condition in pediatric and adult penetrating keratoplasty (PK). Seventy-two eyes of 65 infants and children and 44 eyes of 44 adult patients were operated on using this technique. After trephining the recipient cornea up to a depth of 50% to 70%, the anterior chamber was entered at 1 point. Then, only a 2 clock hour segment of the recipient button was incised, and this segment was sutured to the recipient rim with a single tight suture. The procedure was repeated until the entire recipient button was excised and resutured. The donor corneal button was sutured to the recipient corneal rim. The sutures between the recipient button and the rim were then cut off, and the recipient button was drawn out. None of the patients operated on with this technique developed complications related to the open-sky condition. Visual acuities, graft failure rates, and endothelial cell loss were comparable with the findings of studies performed for conventional PK. The technique described avoids the open-sky condition during the entire PK procedure. Endothelial cell loss rates are acceptable.

  2. [Autoshaping of a button-push response and eye movement in human subjects].

    PubMed

    Kimura, H; Fukui, I; Inaki, K

    1990-12-01

    Two experiments were conducted with human subjects to investigate the similarities and differences between animal and human behaviors under autoshaping procedures. In these experiments, light served as CS, and display on TV served as US. Whether the pushing button response or gazing response to CS could be obtained in human subjects under Pavlovian conditioning procedure was examined. In Experiment 1, uninstructed naive subjects were placed in a room containing a push-button and a TV display. Within the experimental sessions, the push-button was lit for 8 s as CS, and then paired with the display of a soft pornographic program on TV for 10 s. The result indicated that the modeling of pushing button promoted the increase of response probability among the subjects. The trials conducted after the rest period indicated an increase of response probability. In Experiment 2, a 4 cm square translucent panel was lit for 20 s as CS, and then paired with the display of a computer graphic picture on TV for 8 s as US. Some subjects started gazing at the CS for several seconds. These results indicated that some subjects could acquire the gazing response under the autoshaping procedure.

  3. Rehabilitation Approaches in Macular Degeneration Patients

    PubMed Central

    Maniglia, Marcello; Cottereau, Benoit R.; Soler, Vincent; Trotter, Yves

    2016-01-01

    Age related macular degeneration (AMD) is a visual disease that affects elderly population. It entails a progressive loss of central vision whose consequences are dramatic for the patient’s quality of life. Current rehabilitation programs are restricted to technical aids based on visual devices. They only temporarily improve specific visual functions such as reading skills. Considering the rapid increase of the aging population worldwide, it is crucial to intensify clinical research on AMD in order to develop simple and efficient methods that improve the patient’s visual performances in many different contexts. One very promising approach to face this challenge is based on perceptual learning (PL). Through intensive practice, PL can induce neural plasticity in sensory cortices and result in long-lasting enhancements for various perceptual tasks in both normal and visually impaired populations. A growing number of studies showed how appropriate PL protocols improve visual functions in visual disorders, namely amblyopia, presbyopia or myopia. In order to successfully apply these approaches to more severe conditions such as AMD, numerous challenges have to be overcome. Indeed, the overall elderly age of patients and the reduced cortical surface that is devoted to peripheral vision potentially limit neural plasticity in this population. In addition, ocular fixation becomes much less stable because patients have to rely on peripheral fixation spots outside the scotoma whose size keeps on evolving. The aim of this review article is to discuss the recent literature on this topic and to offer a unified approach for developing new rehabilitation programs of AMD using PL. We argue that with an appropriate experimental and training protocol that is adapted to each patient needs, PL can offer fascinating opportunities for the development of simple, non-expensive rehabilitation approaches a large spectrum of visual functions in AMD patients. PMID:28082876

  4. Results of a bone splint technique for the treatment of lower limb deformities in children with type I osteogenesis imperfecta

    PubMed Central

    Lin, Dasheng; Zhai, Wenliang; Lian, Kejian; Ding, Zhenqi

    2013-01-01

    Background: Children with osteogenesis imperfecta (OI) can suffer from frequent fractures and limb deformities, resulting in impaired ambulation. Osteopenia and thin cortices complicate orthopedic treatment in this group. This study evaluates the clinical results of a bone splint technique for the treatment of lower limb deformities in children with type I OI. The technique consists of internal plating combined with cortical strut allograft fixation. Materials and Methods: We prospectively followed nine children (five boys, four girls) with lower limb deformities due to type I OI, who had been treated with the bone splint technique (11 femurs, four tibias) between 2003 and 2006. The fracture healing time, deformity improvement, ambulation ability and complications were recorded to evaluate treatment effects. Results: At the time of surgery the average age in our study was 7.7 years (range 5-12 years). The average length of followup was 69 months (range 60-84 months). All patients had good fracture healing with an average healing time of 14 weeks (range 12-16 weeks) and none experienced further fractures, deformity, or nonunion. The fixation remained stable throughout the procedure in all cases, with no evidence of loosening or breakage of screws and the deformity and mobility significantly improved after surgery. Of the two children confined to bed before surgery, one was able to walk on crutches and the other needed a wheelchair. The other seven patients could walk without walking aids or support like crutches. Conclusions: These findings suggest that the bone splint technique provides good mechanical support and increases the bone mass. It is an effective treatment for children with OI and lower limb deformities. PMID:23960282

  5. Surgical treatment of scapulohumeral subluxation in an alpaca (Vicugna pacos) using osteotomy of the acromion, open reduction and extracapsular tension sutures.

    PubMed

    Kofler, J; Eberspächer, E; Fischl, K; Vidoni, B

    2016-05-01

    A 3.3-year-old male alpaca, weighing 60 kg was referred for investigation of a severe left forelimb lameness of 4 weeks duration. A scapulohumeral subluxation had been diagnosed radiographically by the referring veterinarian. Based on clinical, ultrasonographic and radiographic findings the diagnosis of cranio-lateral subluxation of the left humeral head was confirmed. In addition, a full thickness lesion (approximately 1×1 cm) of the articular cartilage on the caudomedial aspect of the humeral head was diagnosed by arthroscopy. Treatment included open reduction with internal fixation. Severe muscle contraction and local tissue fibrosis around the scapulohumeral joint (SHJ) required osteotomy of the acromion 3 cm proximal to the distal acromial edge, to allow adequate access. Internal stabilisation was achieved by placing tension band sutures between one cortical screw in the scapular neck and two cortical screws, with washers, craniolaterally on the greater tubercle of the humerus. Post-surgery, a carpal flexion sling was applied with the carpus maintained in 70° flexion for 4 weeks to avoid postoperative weight-bearing. An exercise programme was started 8 days after surgery and continued for 12 weeks. The alpaca had an uneventful postsurgical recovery and showed no lameness after 8 weeks. The long-term outcome was excellent; 21 months after surgery the alpaca was sound and the range of movement of the left SHJ was equal to the right SHJ. Even in this chronic case of subluxation of the SHJ of 4 weeks duration, surgical treatment using osteotomy of the acromion, open reduction and internal fixation with extracapsular scapulohumeral tension sutures resulted in an excellent long-term outcome in this alpaca, despite the presence of a cartilage lesion.

  6. Soft robot design methodology for `push-button' manufacturing

    NASA Astrophysics Data System (ADS)

    Paik, Jamie

    2018-06-01

    `Push-button' or fully automated manufacturing would enable the production of robots with zero intervention from human hands. Realizing this utopia requires a fundamental shift from a sequential (design-materials-manufacturing) to a concurrent design methodology.

  7. MedlinePlus FAQ: Disease or Condition Information

    MedlinePlus

    ... on the Health Topics button on the MedlinePlus homepage. You can also find the Health Topics button ... MedlinePlus Connect for EHRs For Developers U.S. National Library of Medicine 8600 Rockville Pike, Bethesda, MD 20894 ...

  8. Development of non-keyboard input device checklists through assessments.

    PubMed

    Woods, Valerie; Hastings, Sarah; Buckle, Peter; Haslam, Roger

    2003-11-01

    An assessment of non-keyboard input devices (NKID) was conducted to identify factors for good design in relation to operation, performance and comfort. Twenty-seven NKID users, working in health and safety, evaluated eight devices that included mice, trackballs and a joystick mouse. The factors considered important for good design were: (1) comfortable hand and finger position, (2) adequate control, (3) intuitive and easy to use, (4) ease of device, button and trackball movement, (5) good interaction with software, (6) provision of suitable accessories. Mice were rated more favourably than trackballs or the joystick mouse. The design of the standard 2-button mouse (D4) was considered most desirable to use; the 3-button mouse (D1) and 3-button curved mouse (D8) were also favoured. Assessment data and comments were drawn together with previously published research to produce useful tools for NKID purchasing (i.e. Device Purchasing Checklist) and assessment (i.e. Device Assessment Checklist).

  9. Interference between oculomotor and postural tasks in 7-8-year-old children and adults.

    PubMed

    Legrand, Agathe; Doré Mazars, Karine; Lemoine, Christelle; Nougier, Vincent; Olivier, Isabelle

    2016-06-01

    Several studies in adults having observed the effect of eye movements on postural control provided contradictory results. In the present study, we explored the effect of various oculomotor tasks on postural control and the effect of different postural tasks on eye movements in eleven children (7.8 ± 0.5 years) and nine adults (30.4 ± 6.3 years). To vary the difficulty of the oculomotor task, three conditions were tested: fixation, prosaccades (reactive saccades made toward the target) and antisaccades (voluntary saccades made in the direction opposite to the visual target). To vary the difficulty of postural control, two postural tasks were tested: Standard Romberg (SR) and Tandem Romberg (TR). Postural difficulty did not affect oculomotor behavior, except by lengthening adults' latencies in the prosaccade task. For both groups, postural control was altered in the antisaccade task as compared to fixation and prosaccade tasks. Moreover, a ceiling effect was found in the more complex postural task. This study highlighted a cortical interference between oculomotor and postural control systems.

  10. Why are there eccentricity effects in visual search? Visual and attentional hypotheses.

    PubMed

    Wolfe, J M; O'Neill, P; Bennett, S C

    1998-01-01

    In standard visual search experiments, observers search for a target item among distracting items. The locations of target items are generally random within the display and ignored as a factor in data analysis. Previous work has shown that targets presented near fixation are, in fact, found more efficiently than are targets presented at more peripheral locations. This paper proposes that the primary cause of this "eccentricity effect" (Carrasco, Evert, Chang, & Katz, 1995) is an attentional bias that allocates attention preferentially to central items. The first four experiments dealt with the possibility that visual, and not attentional, factors underlie the eccentricity effect. They showed that the eccentricity effect cannot be accounted for by the peripheral reduction in visual sensitivity, peripheral crowding, or cortical magnification. Experiment 5 tested the attention allocation model and also showed that RT x set size effects can be independent of eccentricity effects. Experiment 6 showed that the effective set size in a search task depends, in part, on the eccentricity of the target because observers search from fixation outward.

  11. The Additively Manufactured Porous NiTi and Ti-6Al-4V in Mandibular Reconstruction: Introducing the Stiffness-Matched and the Variable Stiffness Options for the Reconstruction Plates

    NASA Astrophysics Data System (ADS)

    Jahadakbar, Ahmadreza

    Mandibular reconstruction surgery is a part of treatment for cancer, tumor, and all the cases that involve segmental defects. One of the most common approaches for the reconstruction surgery is to resect the segmental defect and use a double barrel fibula graft to fill the resected region and recover the mandible's normal functions, such as chewing. The grafted bone is connected to the host mandible, using the standard of the care Ti-6Al-4V fixation plates. The fixation plates are available in the form of prefabricated plates and also patient-specific plates in the market. Due to the high stiffness of the Ti-6Al-4V plates in comparison with the mandible bone and the grafted bone, the loading distribution on the whole reconstructed mandible will be different from a healthy mandible. The high stiffness fixation hardware carries a great portion of the loading and causes stress shielding on the grafted bone and the surrounding host bone. Based on the bone remodeling theory, the stress shielding on the cortical bone causes bone resorption and may lead to implant failure. A solution to reduce the risk of implant failure is to use a low stiffness biocompatible material for the mandibular fixation plates. We have proposed the use of stiffness-matched, porous NiTi fixation plates either in the form of patient-specific or prefabricated, instead of the standard of the care Ti-6Al-4V plates. NiTi is a biocompatible material that has a low stiffness in comparison with Ti-6Al-4V and also benefits from the superelastic feature. Superelasticity, which can also be found in bone tissues, allows the material to recover large strains (up to 8%) and increases the shock absorption. In this thesis, we have evaluated the use of proposed fixation hardware by comparing it with a healthy mandible and a reconstructed mandible using the standard method. To this end, first different models including a healthy mandible, a reconstructed mandible using patient-specific Ti-6Al-4V fixation hardware, a reconstructed mandible using stiffness-match patient-specific hardware, and several prefabricated fixation plates were prepared. After verification of the models, the cases of reconstructed mandibles were used to simulate different periods, including during healing, and post-healing periods. Also, different loading conditions including highest bite force on the first molar tooth, rest condition, and also highest bite force on a dental implant right in the grafted bone were simulated. Also, the theory of applying pretention to the fixation plates was evaluated using the finite element method. We also designed and evaluated a set of prefabricated fixation kits with various stiffness option. After all these finite element simulations and having the CAD files of the porous fixation plates, the possibility of fabrication of the proposed hardware, in both forms of patient-specific, and prefabricated plates was evaluated using selective laser melting.

  12. The biomechanical effect of artificial and human bone density on stopping and stripping torque during screw insertion.

    PubMed

    Tsuji, Matthew; Crookshank, Meghan; Olsen, Michael; Schemitsch, Emil H; Zdero, Rad

    2013-06-01

    Orthopedic surgeons apply torque to metal screws manually by "subjective feel" to obtain adequate fracture fixation, i.e. stopping torque, and attempt to avoid accidental over-tightening that leads to screw-bone interface failure, i.e. stripping torque. Few studies have quantified stripping torque in human bone, and only one older study from 1980 reported stopping/ stripping torque ratio. The present aim was to measure stopping and stripping torque of cortical and cancellous screws in artificial and human bone over a wide range of densities. Sawbone blocks were obtained having densities from 0.08 to 0.80g/cm(3). Sixteen fresh-frozen human femurs of known standardized bone mineral density (sBMD) were also used. Using a torque screwdriver, 3.5-mm diameter cortical screws and 6.5-mm diameter cancellous screws were inserted for adequate tightening as determined subjectively by an orthopedic surgeon, i.e. stopping torque, and then further tightened until failure of the screw-bone interface, i.e. stripping torque. There were weak (R=0.25) to strong (R=0.99) linear correlations of absolute and normalized torque vs. density or sBMD. Maximum stopping torques normalized by screw thread area engaged by the host material were 15.2N/mm (cortical screws) and 13.4N/mm (cancellous screws) in sawbone blocks and 20.9N/mm (cortical screws) and 6.1N/mm (cancellous screws) in human femurs. Maximum stripping torques normalized by screw thread area engaged by the host material were 23.4N/mm (cortical screws) and 16.8N/mm (cancellous screws) in sawbone blocks and 29.3N/mm (cortical screws) and 8.3N/mm (cancellous screws) in human femurs. Combined average stopping/ stripping torque ratios were 80.8% (cortical screws) and 76.8% (cancellous screws) in sawbone blocks, as well as 66.6% (cortical screws) and 84.5% (cancellous screws) in human femurs. Surgeons should be aware of stripping torque limits for human femurs and monitor stopping torque during surgery. This is the first study of the effect of sawbone density or human bone sBMD on stopping and stripping torque. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Effects of contamination by either blood or a hemostatic agent on the shear bond strength of orthodontic buttons

    PubMed Central

    Alkis, Huseyin; Turkkahraman, Hakan

    2013-01-01

    Objective To evaluate the effects of contamination by either blood or a hemostatic agent on the shear bond strength (SBS) of orthodontic buttons. Methods We used 45 freshly extracted, non-carious, impacted third molars that were divided into 3 groups of 15. Each tooth was etched with 37% phosphoric acid gel for 30 s. Human blood or the blood stopper agent was applied to the tooth surface in groups I and II, respectively. Group III teeth were untreated (controls). Orthodontic buttons were bonded to the teeth using light-curing composite resin. After bonding, the SBS of the button was determined using a Universal testing machine. Any adhesive remaining after debonding was assessed and scored according to the modified adhesive remnant index (ARI). ANOVA with post-hoc Tukey's test was used to determine significant differences in SBS and Fisher's exact test, to determine significant differences in ARI scores among groups. Results ANOVA indicated a significant difference between groups (p < 0.001). The highest SBS values were measured in group III (10.73 ± 0.96 MPa). The SBS values for teeth in groups I and II were significantly lower than that of group III (p < 0.001). The lowest SBS values were observed in group I teeth (4.17 ± 1.11 MPa) (p < 0.001). Conclusions Contamination of tooth surfaces with either blood or hemostatic agent significantly decreased the SBS of orthodontic buttons. When the contamination risk is high, it is recommended to use the blood stopper agent when bonding orthodontic buttons on impacted teeth. PMID:23671834

  14. Smoke alarm tests may not adequately indicate smoke alarm function.

    PubMed

    Peek-Asa, Corinne; Yang, Jingzhen; Hamann, Cara; Young, Tracy

    2011-01-01

    Smoke alarms are one of the most promoted prevention strategies to reduce residential fire deaths, and they can reduce residential fire deaths by half. Smoke alarm function can be measured by two tests: the smoke alarm button test and the chemical smoke test. Using results from a randomized trial of smoke alarms, we compared smoke alarm response to the button test and the smoke test. The smoke alarms found in the study homes at baseline were tested, as well as study alarms placed into homes as part of the randomized trial. Study alarms were tested at 12 and 42 months postinstallation. The proportion of alarms that passed the button test but not the smoke test ranged from 0.5 to 5.8% of alarms; this result was found most frequently among ionization alarms with zinc or alkaline batteries. These alarms would indicate to the owner (through the button test) that the smoke alarm was working, but the alarm would not actually respond in the case of a fire (as demonstrated by failing the smoke test). The proportion of alarms that passed the smoke test but not the button test ranged from 1.0 to 3.0%. These alarms would appear nonfunctional to the owner (because the button test failed), even though the alarm would operate in response to a fire (as demonstrated by passing the smoke test). The general public is not aware of the potential for inaccuracy in smoke alarm tests, and burn professionals can advocate for enhanced testing methods. The optimal test to determine smoke alarm function is the chemical smoke test.

  15. The validity, reliability, and utility of the iButton® for measurement of body temperature circadian rhythms in sleep/wake research.

    PubMed

    Hasselberg, Michael J; McMahon, James; Parker, Kathy

    2013-01-01

    Changes in core body temperature due to heat transfer through the skin have a major influence on sleep regulation. Traditional measures of skin temperature are often complicated by extensive wiring and are not practical for use in normal living conditions. This review describes studies examining the reliability, validity and utility of the iButton®, a wireless peripheral thermometry device, in sleep/wake research. A review was conducted of English language literature on the iButton as a measure of circadian body temperature rhythms associated with the sleep/wake cycle. Seven studies of the iButtton as a measure of human body temperature were included. The iButton was found to be a reliable and valid measure of body temperature. Its application to human skin was shown to be comfortable and tolerable with no significant adverse reactions. Distal skin temperatures were negatively correlated with sleep/wake activity, and the temperature gradient between the distal and proximal skin (DPG) was identified as an accurate physiological correlate of sleep propensity. Methodological issues included site of data logger placement, temperature masking factors, and temperature data analysis. The iButton is an inexpensive, wireless data logger that can be used to obtain a valid measurement of human skin temperature. It is a practical alternative to traditional measures of circadian rhythms in sleep/wake research. Further research is needed to determine the utility of the iButton in vulnerable populations, including those with neurodegenerative disorders and memory impairment and pediatric populations. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. [A method for inducing standardized spiral fractures of the tibia in the animal experiment].

    PubMed

    Seibold, R; Schlegel, U; Cordey, J

    1995-07-01

    A method for the deliberate weakening of cortical bone has been developed on the basis of an already established technique for creating butterfly fractures. It enables one to create the same type of fracture, i.e., a spiral fracture, every time. The fracturing process is recorded as a force-strain curve. The results of the in vitro investigations form a basis for the preparation of experimental tasks aimed at demonstrating internal fixation techniques and their influence on the vascularity of the bone in simulated fractures. Animal protection law lays down that this fracture model must not fail in animal experiments.

  17. 78 FR 27995 - Notice of Inventory Completion for Native American Human Remains and Associated Funerary Objects...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ... fragments, 29 historic ceramic sherds, 1 prehistoric ceramic sherd, 128 unmodified faunal bone fragments, 1 modified deer rib, 3 bone buttons, 4 chipped stone flakes, 2 wooden buttons, 1 historic clay pipe bowl...

  18. Comparison of numeric keyboard and CRT line-labeled buttons for information access. [in computerized, area navigation system for aircraft

    NASA Technical Reports Server (NTRS)

    Williams, D.

    1976-01-01

    Test were conducted to determine whether differences in speed and accuracy are experienced when using either line-labeled index buttons or a numeric keyboard for page selection in airborne CRT-display area navigation systems. The experiment was conducted with six airline pilots, each flying the same two simulated RNAV routes. Three pilot subjects used line-labeled buttons adjacent to the CRT screen, while three used a numeric keyboard for page access. The hypothesis of no differences in response times between the two modes of access could not be rejected.

  19. Button battery ingestion: the Greek experience and review of the literature.

    PubMed

    Amanatidou, Virginia; Sofidiotou, Vassiliki; Fountas, Kostas; Kalostou, Angeliki; Tsamadou, Athina; Papathanassiou, Vassiliki; Neou, Polyxeni

    2011-03-01

    Foreign body ingestion is a common cause of admission in the pediatric emergency room. In the past, button batteries accounted for less than 2% of the foreign bodies ingested by small children, but in the last 2 decades, they show a rapidly increased frequency. The aim of the present study was to evaluate the potential risk after button battery ingestion in relation with the clinical manifestations and to perform a treatment-observation protocol in accordance with the international procedure. In a prospective observational analysis from November 2007 through February 2008, 31 cases of button battery ingestion were recorded by the Greek Poison Information Center. The interval between the accidental ingestion and first medical contact ranged from 5 minutes to 10 days. After initial evaluation including clinical examination and radiological localization of the foreign body, all cases were treated as outpatients. Reported complications included "black stools" in 9% and diarrhea in 3% of cases. In 1 case, the battery was endoscopically removed. The role of primary care physicians in informing the public about the potential danger of button battery digestion is crucial. Pediatricians should educate the parents about this hazard, as part of the routine guidelines for childproofing at home. Once again, prolepsis is the best policy.

  20. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting

    PubMed Central

    Baksi, D D; Pal, A K; Baksi, D P

    2016-01-01

    Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8–30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN) of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG) were excluded. Thus, out of 244 patients, 208 (85.3%) untreated nonunion and 36 (14.7%) following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN) femoral head was found histologically in 135 (54.3%) and radiologically in 48 (19.7%) patients. The patients were operated by open reduction of fracture, cannulated hip screw fixation, iliac crest bone chips and quadratus femoris MPBG. Results: The mean followup is 12.5 years (range 3-35). The union of fractures occurred in 202 (82.8%), delayed union in 18 (7.3%), and established nonunion in 24 (9.8%) patients. Full weight bearing was permitted at 16–22 weeks after union of fractures. Mean Harris hip score at the longest followup was 85.5. Among the complications, superficial wound infection occurred in 20 (8.2%), deep infection in seven (2.9%), and coxa vara in 39 (16%) patients. Preoperative radiodensity of femoral head disappeared mostly after the union of fracture whereas fresh radiodensity of femoral head appeared in 20 (8%) patients; nine (45%) of them developed segmental collapse. Conclusion: Ununited femoral neck fractureis characterized by absorption of femoral neck, posterior cortical defect, smoothening and overriding of fracture surfaces with intervening fibrous tissues associated with or without AVN of femoral head. The above method of osteosynthesis rectified the above pathology and provided satisfactory results with union of fractures in 90.1% patients at long term followup. PMID:27512217

  1. Scaphoid Waist Internal Fixation for Fractures Trial (SWIFFT) protocol: a pragmatic multi-centre randomised controlled trial of cast treatment versus surgical fixation for the treatment of bi-cortical, minimally displaced fractures of the scaphoid waist in adults.

    PubMed

    Dias, Joseph; Brealey, Stephen; Choudhary, Surabhi; Cook, Liz; Costa, Matthew; Fairhurst, Caroline; Hewitt, Catherine; Hodgson, Stephen; Jefferson, Laura; Jeyapalan, Kanagaratnam; Keding, Ada; Leighton, Paul; Rangan, Amar; Richardson, Gerry; Rothery, Claire; Taub, Nicholas; Thompson, John; Torgerson, David

    2016-06-04

    A scaphoid fracture is the most common type of carpal fracture affecting young active people. The optimal management of this fracture is uncertain. When treated with a cast, 88 to 90 % of these fractures unite; however, for the remaining 10-12 % the non-union almost invariably leads to arthritis. The alternative is surgery to fix the scaphoid with a screw at the outset. We will conduct a randomised controlled trial (RCT) of 438 adult patients with a "clear" and "bicortical" scaphoid waist fracture on plain radiographs to evaluate the clinical effectiveness and cost-effectiveness of plaster cast treatment (with fixation of those that fail to unite) versus early surgical fixation. The plaster cast treatment will be immobilisation in a below elbow cast for 6 to 10 weeks followed by mobilisation. If non-union is confirmed on plain radiographs and/or Computerised Tomogram at 6 to 12 weeks, then urgent surgical fixation will be performed. This is being compared with immediate surgical fixation with surgeons using their preferred technique and implant. These treatments will be undertaken in trauma units across the United Kingdom. The primary outcome and end-point will be the Patient Rated Wrist Evaluation (a patient self-reported assessment of wrist pain and function) at 52 weeks and also measured at 6, 12, 26 weeks and 5 years. Secondary outcomes include an assessment of radiological union of the fracture; quality of life; recovery of wrist range and strength; and complications. We will also qualitatively investigate patient experiences of their treatment. Scaphoid fractures are an important public health problem as they predominantly affect young active individuals in the more productive working years of their lives. Non-union, if untreated, can lead to arthritis which can disable patients at a very young age. There is a rapidly increasing trend for immediate surgical fixation of these fractures but there is insufficient evidence from existing RCTs to support this. The SWIFFT Trial is a rigorously designed and adequately powered study which aims to contribute to the evidence-base to inform clinical decisions for the treatment of this common fracture in adults. The trial is registered with the International Standard Randomised Controlled Trial Register ( ISRCTN67901257 ). Date registration assigned was 13/02/2013.

  2. Insertion torque in different bone models with different screw pitch: an in vitro study.

    PubMed

    Orlando, Bruno; Barone, Antonio; Giorno, Thierry M; Giacomelli, Luca; Tonelli, Paolo; Covani, Ugo

    2010-01-01

    Orthopedic surgeons use different types of screws for bone fixation. Whereas hard cortical bone requires a screw with a fine pitch, in softer cancellous bone a wider pitch might help prevent micromotion and eventually lead to greater implant stability. The aim of this study was to validate the assumption that fine-pitch implants are appropriate for cortical bone and wide-pitch implants are appropriate for cancellous bone. Wide-pitch and fine-pitch implants were inserted in both hard (D1 and D2) bone and soft (D3 and D4) bone, which was simulated by separate experimental blocks of cellular rigid polyurethane foam. A series of insertion sites in D1-D2 and D3-D4 experimental blocks were prepared using 1.5-mm and 2.5-mm drills. The final torque required to insert each implant was recorded. Wide-pitch implants displayed greater insertion torque (20% more than the fine-pitch implants) in cancellous bone and were therefore more suitable than fine-pitch implants. It is more appropriate to use a fine pitch design for implants, in conjunction with a 2.5-mm osteotomy site, in dense cortical bone (D1 or D2), whereas it is recommended to choose a wide-pitch design for implants, in conjunction with a 1.5-mm osteotomy site, in softer bone (D3 or D4).

  3. Assessing bone volume for orthodontic miniplate fixation below the maxillary frontal process.

    PubMed

    Präger, T M; Brochhagen, H G; Mischkowski, R; Jost-Brinkmann, P-G; Müller-Hartwich, R

    2014-09-01

    The maxillary bone below the frontal process is used for orthodontic anchorage; indications have included skeletally anchored protraction of the maxilla for treating Class III malocclusions or the intrusion of teeth in patients with a deep bite. This study was conducted to assess the condition of bone before cortically implanting miniplates in that area of the maxilla. A total of 51 thin-sliced computed tomography scans of 51 fully-dentate adult patients (mean age 24.0 ± 8.1 years; 27 men and 24 women) obtained prior to third-molar osteotomy were evaluated. Study parameters included total bone thickness, thickness of the facial cortical plate, and width of the nasal maxillary buttress. All these parameters were measured at different vertical levels. The bone volume adjacent to the piriform aperture was most pronounced at the basal level and decreased progressively toward more cranial levels. The basal bone structure had a mean total thickness of 7.8 mm, facial cortical plate thickness of 1.9 mm, and nasal maxillary buttress width of 9.2 mm. At 16 mm cranial to the aperture base, these values fell to 5.6 mm, 1.3 mm, and 5.8 mm, respectively. These bone measurements suggest that screws 7 mm in length can be inserted at the base level of the piriform aperture and screws 5 mm long at the cranial end of the bone.

  4. Comparison of Neck Screw and Conventional Fixation Techniques in Mandibular Condyle Fractures Using 3-Dimensional Finite Element Analysis.

    PubMed

    Conci, Ricardo Augusto; Tomazi, Flavio Henrique Silveira; Noritomi, Pedro Yoshito; da Silva, Jorge Vicente Lopes; Fritscher, Guilherme Genehr; Heitz, Claiton

    2015-07-01

    To compare the mechanical stress on the mandibular condyle after the reduction and fixation of mandibular condylar fractures using the neck screw and 2 other conventional techniques according to 3-dimensional finite element analysis. A 3-dimensional finite element model of a mandible was created and graphically simulated on a computer screen. The model was fixed with 3 different techniques: a 2.0-mm plate with 4 screws, 2 plates (1 1.5-mm plate and 1 2.0-mm plate) with 4 screws, and a neck screw. Loads were applied that simulated muscular action, with restrictions of the upper movements of the mandible, differentiation of the cortical and medullary bone, and the virtual "folds" of the plates and screws so that they could adjust to the condylar surface. Afterward, the data were exported for graphic visualization of the results and quantitative analysis was performed. The 2-plate technique exhibited better stability in regard to displacement of fractures, deformity of the synthesis materials, and minimum and maximum tension values. The results with the neck screw were satisfactory and were similar to those found when a miniplate was used. Although the study shows that 2 isolated plates yielded better results compared with the other groups using other fixation systems and methods, the neck screw could be an option for condylar fracture reduction. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Stable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases.

    PubMed

    Nebergall, Audrey; Bragdon, Charles; Antonellis, Anne; Kärrholm, Johan; Brånemark, Rickard; Malchau, Henrik

    2012-04-01

    Rehabilitation of patients with transfemoral amputations is particularly difficult due to problems in using standard socket prostheses. We wanted to assess long-term fixation of the osseointegrated implant system (OPRA) using radiostereometric analysis (RSA) and periprosthetic bone remodeling. 51 patients with transfemoral amputations (55 implants) were enrolled in an RSA study. RSA and plain radiographs were scheduled at 6 months and at 1, 2, 5, 7, and 10 years after surgery. RSA films were analyzed using UmRSA software. Plain radiographs were graded for bone resorption, cancellization, cortical thinning, and trabecular streaming or buttressing in specifically defined zones around the implant. At 5 years, the median (SE) migration of the implant was -0.02 (0.06) mm distally. The rotational movement was 0.42 (0.32) degrees around the longitudinal axis. There was no statistically significant difference in median rotation or migration at any follow-up time. Cancellization of the cortex (plain radiographic grading) appeared in at least 1 zone in over half of the patients at 2 years. However, the prevalence of cancellization had decreased by the 5-year follow-up. The RSA analysis for the OPRA system indicated stable fixation of the implant. The periprosthetic bone remodeling showed similarities with changes seen around uncemented hip stems. The OPRA system is a new and promising approach for addressing the challenges faced by patients with transfemoral amputations.

  6. CAD-CAM plates versus conventional fixation plates for primary mandibular reconstruction: A biomechanical in vitro analysis.

    PubMed

    Rendenbach, Carsten; Sellenschloh, Kay; Gerbig, Lucca; Morlock, Michael M; Beck-Broichsitter, Benedicta; Smeets, Ralf; Heiland, Max; Huber, Gerd; Hanken, Henning

    2017-11-01

    CAD/CAM reconstruction plates have become a viable option for mandible reconstruction. The aim of this study was to determine whether CAD/CAM plates provide higher fatigue strength compared with conventional fixation systems. 1.0 mm miniplates, 2.0 mm conventional locking plates (DePuy Synthes, Umkirch, Germany), and 2.0 mm CAD/CAM plates (Materialise, Leuven, Belgium/DePuy Synthes) were used to reconstruct a polyurethane mandible model (Synbone, Malans, CH) with cortical and cancellous bone equivalents. Mastication was simulated via cyclic dynamic testing using a universal testing machine (MTS, Bionix, Eden Prairie, MN, USA) until material failure reached a rate of 1 Hz with increasing loads on the left side. No significant difference was found between the groups until a load of 300 N. At higher loads, vertical displacement differed increasingly, with a poorer performance of miniplates (p = 0.04). Plate breakage occurred in miniplates and conventional locking plates. Screw breakage was recorded as the primary failure mechanism in CAD/CAM plates. Stiffness was significantly higher with the CAD/CAM plates (p = 0.04). CAD/CAM plates and reconstruction plates provide higher fatigue strength than miniplates, and stiffness is highest in CAD/CAM systems. All tested fixation methods seem sufficiently stable for mandible reconstruction. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  7. Percutaneous Instrumentation of a Complex Lumbar Spine Fracture with Bilateral Pedicle Dissociation: Case Report and Technical Note.

    PubMed

    Luther, Evan; Urakov, Timur; Vanni, Steven

    2018-06-11

     Complex traumatic lumbar spine fractures are difficult to manage and typically occur in younger patients. Surgical immobilization for unstable fractures is an accepted treatment but can lead to future adjacent-level disease. Furthermore, large variations in fracture morphology create significant difficulties when attempting fixation. Therefore, a surgical approach that considers both long-term outcomes and fracture type is of utmost importance. We present a novel technique for percutaneous fixation without interbody or posterolateral fusion in a young patient with bilateral pedicle dissociations and an acute-onset incomplete neurologic deficit.  A 20-year-old man involved in a motorcycle accident presented with unilateral right lower extremity paresis and sensory loss with intact rectal tone and no saddle anesthesia. Lumbar computed tomography (CT) demonstrated L2 and L3 fractures associated with bilateral pedicle dislocations. Lumbar magnetic resonance imaging showed draping of the conus medullaris/cauda equina anteriorly over the kyphotic deformity at L2 with minimal associated canal stenosis at L2 and L3. He was treated with emergent percutaneous fixation of the fracture segment without interbody or posterolateral fusion. Decompression was not performed because of the negligible amount of canal stenosis and high likelihood of cerebrospinal fluid leakage due to dural tears from the fractures. Surgical fixation of the L2 vertebra was achieved by cannulating the left pedicle with an oversized tap while holding the right pedicle in place with a normal tap and then driving screws into the left and right pedicles, respectively, thus reducing the free-floating fracture segment. At 18 months after surgery, a follow-up CT demonstrated good cortication across the prior pedicle fractures, and the instrumentation was removed without any obvious signs of instability or disruption of the alignment at the thoracolumbar junction.  We present a novel technique for percutaneous reduction and fixation of bilateral pedicle fractures with significant dissociation from the vertebral body, associated neural compression from the kyphotic deformity, and minimal spinal canal stenosis. Furthermore, we argue that early fixation and reduction of the fracture prevented irreversible neurologic compromise, and the absence of interbody or posterolateral fusion ultimately preserved the spinal mobility of the patient once the hardware was removed. Georg Thieme Verlag KG Stuttgart · New York.

  8. Disposable Electronic Cigarettes and Electronic Hookahs: Evaluation of Performance

    PubMed Central

    Williams, Monique; Ghai, Sanjay

    2015-01-01

    Introduction: The purpose of this study was to characterize the performance of disposable button-activated and disposable airflow-activated electronic cigarettes (EC) and electronic hookahs (EH). Methods: The airflow rate required to produce aerosol, pressure drop, and the aerosol absorbance at 420nm were measured during smoke-outs of 9 disposable products. Three units of each product were tested in these experiments. Results: The airflow rates required to produce aerosol and the aerosol absorbances were lower for button-activated models (3mL/s; 0.41–0.55 absorbance) than for airflow-activated models (7–17mL/s; 0.48–0.84 absorbance). Pressure drop was also lower across button-activated products (range = 6–12mm H2O) than airflow-activated products (range = 15–67mm H20). For 25 of 27 units tested, airflow did not have to be increased during smoke-out to maintain aerosol production, unlike earlier generation models. Two brands had uniform performance characteristics for all parameters, while 3 had at least 1 product that did not function normally. While button-activated models lasted 200 puffs or less and EH airflow-activated models often lasted 400 puffs, none of the models produced as many puffs as advertised. Puff number was limited by battery life, which was shorter in button-activated models. Conclusion: The performance of disposable products was differentiated mainly by the way the aerosol was produced (button vs airflow-activated) rather than by product type (EC vs EH). Users needed to take harder drags on airflow-activated models. Performance varied within models, and battery life limited the number of puffs. Data suggest quality control in manufacturing varies among brands. PMID:25104117

  9. Insertion of Balloon Retained Gastrostomy Buttons: A 5-Year Retrospective Review of 260 Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Power, Sarah, E-mail: sarahpower28@yahoo.co.uk; Kavanagh, Liam N.; Shields, Mary C.

    Radiologically inserted gastrostomy (RIG) is an established way of maintaining enteral nutrition in patients who cannot maintain nutrition orally. The purpose of this study was to evaluate the safety and efficacy of primary placement of a wide bore button gastrostomy in a large, varied patient population through retrospective review. All patients who underwent gastrostomy placement from January 1, 2004 to January 1, 2009 were identified. 18-Fr gastrostomy buttons (MIC-Key G) were inserted in the majority. Follow-up ranged from 6 months to 4.5 years. A total of 260 patients (M:F 140:120, average age 59.2 years) underwent gastrostomy during the study period.more » Overall success rate for RIG placement was 99.6 %, with success rate of 95.3 % for primary button insertion. Indications included neurological disorders (70 %), esophageal/head and neck malignancy (21 %), and other indications (9 %). Major and minor complication rates were 1.2 and 12.8 %, respectively. Thirty-day mortality rate was 6.8 %. One third of patients underwent gastrostomy reinsertion during the study period, the main indication for which was inadvertent catheter removal. Patency rate was high at 99.5 %. The maximum number of procedures in any patient was 8 (n = 2), and the average tube dwell time was 125 days. Primary radiological insertion of a wide bore button gastrostomy is a safe technique, with high success rate, high patency rate, and low major complication rate. We believe that it is feasible to attempt button gastrostomy placement in all patients, once tract length is within limits of tube length. If difficulty is encountered, then a standard tube may simply be placed instead.« less

  10. The joint Simon effect depends on perceived agency, but not intentionality, of the alternative action

    PubMed Central

    Stenzel, Anna; Dolk, Thomas; Colzato, Lorenza S.; Sellaro, Roberta; Hommel, Bernhard; Liepelt, Roman

    2014-01-01

    A co-actor's intentionality has been suggested to be a key modulating factor for joint action effects like the joint Simon effect (JSE). However, in previous studies intentionality has often been confounded with agency defined as perceiving the initiator of an action as being the causal source of the action. The aim of the present study was to disentangle the role of agency and intentionality as modulating factors of the JSE. In Experiment 1, participants performed a joint go/nogo Simon task next to a co-actor who either intentionally controlled a response button with own finger movements (agency+/intentionality+) or who passively placed the hand on a response button that moved up and down on its own as triggered by computer signals (agency−/intentionality−). In Experiment 2, we included a condition in which participants believed that the co-actor intentionally controlled the response button with a Brain-Computer Interface (BCI) while placing the response finger clearly besides the response button, so that the causal relationship between agent and action effect was perceptually disrupted (agency−/intentionality+). As a control condition, the response button was computer controlled while the co-actor placed the response finger besides the response button (agency−/intentionality−). Experiment 1 showed that the JSE is present with an intentional co-actor and causality between co-actor and action effect, but absent with an unintentional co-actor and a lack of causality between co-actor and action effect. Experiment 2 showed that the JSE is absent with an intentional co-actor, but no causality between co-actor and action effect. Our findings indicate an important role of the co-actor's agency for the JSE. They also suggest that the attribution of agency has a strong perceptual basis. PMID:25140144

  11. The joint Simon effect depends on perceived agency, but not intentionality, of the alternative action.

    PubMed

    Stenzel, Anna; Dolk, Thomas; Colzato, Lorenza S; Sellaro, Roberta; Hommel, Bernhard; Liepelt, Roman

    2014-01-01

    A co-actor's intentionality has been suggested to be a key modulating factor for joint action effects like the joint Simon effect (JSE). However, in previous studies intentionality has often been confounded with agency defined as perceiving the initiator of an action as being the causal source of the action. The aim of the present study was to disentangle the role of agency and intentionality as modulating factors of the JSE. In Experiment 1, participants performed a joint go/nogo Simon task next to a co-actor who either intentionally controlled a response button with own finger movements (agency+/intentionality+) or who passively placed the hand on a response button that moved up and down on its own as triggered by computer signals (agency-/intentionality-). In Experiment 2, we included a condition in which participants believed that the co-actor intentionally controlled the response button with a Brain-Computer Interface (BCI) while placing the response finger clearly besides the response button, so that the causal relationship between agent and action effect was perceptually disrupted (agency-/intentionality+). As a control condition, the response button was computer controlled while the co-actor placed the response finger besides the response button (agency-/intentionality-). Experiment 1 showed that the JSE is present with an intentional co-actor and causality between co-actor and action effect, but absent with an unintentional co-actor and a lack of causality between co-actor and action effect. Experiment 2 showed that the JSE is absent with an intentional co-actor, but no causality between co-actor and action effect. Our findings indicate an important role of the co-actor's agency for the JSE. They also suggest that the attribution of agency has a strong perceptual basis.

  12. Method Development for the Determination of Free and Esterified Sterols in Button Mushrooms (Agaricus bisporus).

    PubMed

    Hammann, Simon; Vetter, Walter

    2016-05-04

    Ergosterol is the major sterol in button mushrooms (Agaricus bisporus) and can occur as free alcohol or esterified with fatty acids (ergosteryl esters). In this study, gas chromatography with mass spectrometry in the selected ion monitoring mode (GC/MS-SIM) was used to determine ergosterol and ergosteryl esters as well as other sterols and steryl esters in button mushrooms. Different quality control measures were established and sample preparation procedures were compared to prevent the formation of artifacts and the degradation of ergosteryl esters. The final method was then used for the determination of ergosterol (443 ± 44 mg/100 g dry matter (d.m.)) and esterified ergosterol (12 ± 6 mg/100 g d.m.) in button mushroom samples (n = 4). While the free sterol fraction was vastly dominated by ergosterol (∼90% of five sterols in total), the steryl ester fraction was more diversified (nine sterols in total, ergosterol ∼55%) and consisted primarily of linoleic acid esters.

  13. Changes in non-volatile taste components of button mushroom (Agaricus bisporus) during different stages of freeze drying and freeze drying combined with microwave vacuum drying.

    PubMed

    Pei, Fei; Shi, Ying; Gao, Xingyang; Wu, Fangning; Mariga, Alfred Mugambi; Yang, Wenjian; Zhao, Liyan; An, Xinxin; Xin, Zhihong; Yang, Fangmei; Hu, Qiuhui

    2014-12-15

    Button mushroom slices were dehydrated using freeze drying (FD) or FD combined with microwave vacuum drying (FMVD), and the non-volatile component profiles were studied. The results showed that the level of non-volatile components in button mushroom firstly increased during sublimation of FD/FMVD process and then fell during desorption in FD process and MVD in FMVD process. Compared to FD products, the contents of soluble sugars and polyols in FMVD products were relatively low, whereas the contents of total free amino acids were significantly higher, close to the level of fresh mushroom. However, there was no significant difference in the contents of 5'-nucleotides and organic acids between FD and FMVD products. The equivalent umami concentration (EUC) values for FD and FMVD products did not differ from fresh, indicating that both drying methods could effectively preserve MSG (monosodium glutamate)-like components in button mushroom. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Fractures Due to Gunshot Wounds: Do Retained Bullet Fragments Affect Union?

    PubMed

    Riehl, John T; Connolly, Keith; Haidukewych, George; Koval, Ken

    2015-01-01

    Many types of projectiles, including modern hollow point bullets, fragment into smaller pieces upon impact, particularly when striking bone. This study was performed to examine the effect on time to union with retained bullet material near a fracture site in cases of gunshot injury. All gunshot injuries operatively treated with internal fixation at a Level 1 Trauma Center between March 2008 and August 2011 were retrospectively reviewed. Retained bullet load near the fracture site was calculated based on percentage of material retained compared to the cortical diameter of the involved bone. Analyses were performed to assess the effect of the lead-cortical ratio and amount of comminution on time to fracture union. Thirty-two patients (34 fractures) met the inclusion criteria, with an equal number of comminuted (17) and non-comminuted fractures (17). Seventeen of 34 fractures (50%) united within 4 months, 16/34 (47%) developed a delayed union, and 1/34 (3%) developed a nonunion requiring revision surgery. Sixteen of 17 fractures (94%) that united by 4 months had a cumulative amount of bullet fragmentation retained near the fracture site of less than 20% of the cortical diameter. Nine out of 10 fractures (90%) with retained fragments near the fracture site was equal to or exceeding 20% of the cortical diameter had delayed or nonunion. Fracture comminution had no effect on time to union. The quantity of retained bullet material near the fracture site was more predictive of the rate of fracture union than was comminution. Fractures with bullet fragmentation equal to or exceeding 20% of the cortical width demonstrated a significantly higher rate of delayed union/nonunion compared to those fractures with less retained bullet material, which may indicate a local cytotoxic effect from lead on bone healing. These findings may influence decisions on timing of secondary surgeries. Level III.

  15. Fractures Due to Gunshot Wounds: Do Retained Bullet Fragments Affect Union?

    PubMed Central

    Riehl, John T.; Connolly, Keith; Haidukewych, George; Koval, Ken

    2015-01-01

    Background Many types of projectiles, including modern hollow point bullets, fragment into smaller pieces upon impact, particularly when striking bone. This study was performed to examine the effect on time to union with retained bullet material near a fracture site in cases of gunshot injury. Methods All gunshot injuries operatively treated with internal fixation at a Level 1 Trauma Center between March 2008 and August 2011 were retrospectively reviewed. Retained bullet load near the fracture site was calculated based on percentage of material retained compared to the cortical diameter of the involved bone. Analyses were performed to assess the effect of the lead-cortical ratio and amount of comminution on time to fracture union. Results Thirty-two patients (34 fractures) met the inclusion criteria, with an equal number of comminuted (17) and non-comminuted fractures (17). Seventeen of 34 fractures (50%) united within 4 months, 16/34 (47%) developed a delayed union, and 1/34 (3%) developed a nonunion requiring revision surgery. Sixteen of 17 fractures (94%) that united by 4 months had a cumulative amount of bullet fragmentation retained near the fracture site of less than 20% of the cortical diameter. Nine out of 10 fractures (90%) with retained fragments near the fracture site was equal to or exceeding 20% of the cortical diameter had delayed or nonunion. Fracture comminution had no effect on time to union. Conclusions The quantity of retained bullet material near the fracture site was more predictive of the rate of fracture union than was comminution. Fractures with bullet fragmentation equal to or exceeding 20% of the cortical width demonstrated a significantly higher rate of delayed union/nonunion compared to those fractures with less retained bullet material, which may indicate a local cytotoxic effect from lead on bone healing. These findings may influence decisions on timing of secondary surgeries. Level of Evidence Level III PMID:26361445

  16. Experimental rotator cuff repair. A preliminary study.

    PubMed

    Gerber, C; Schneeberger, A G; Perren, S M; Nyffeler, R W

    1999-09-01

    The repair of chronic, massive rotator cuff tears is associated with a high rate of failure. Prospective studies comparing different repair techniques are difficult to design and carry out because of the many factors that influence structural and clinical outcomes. The objective of this study was to develop a suitable animal model for evaluation of the efficacy of different repair techniques for massive rotator cuff tears and to use this model to compare a new repair technique, tested in vitro, with the conventional technique. We compared two techniques of rotator cuff repair in vivo using the left shoulders of forty-seven sheep. With the conventional technique, simple stitches were used and both suture ends were passed transosseously and tied over the greater tuberosity of the humerus. With the other technique, the modified Mason-Allen stitch was used and both suture ends were passed transosseously and tied over a cortical-bone-augmentation device. This device consisted of a poly(L/D-lactide) plate that was fifteen millimeters long, ten millimeters wide, and two millimeters thick. Number-3 braided polyester suture material was used in all of the experiments. In pilot studies (without prevention of full weight-bearing), most repairs failed regardless of the technique that was used. The simple stitch always failed by the suture pulling through the tendon or the bone; the suture material did not break or tear. The modified Mason-Allen stitch failed in only two of seventeen shoulders. In ten shoulders, the suture material failed even though the stitches were intact. Thus, we concluded that the modified Mason-Allen stitch is a more secure method of achieving suture purchase in the tendon. In eight of sixteen shoulders, the nonaugmented double transosseous bone-fixation technique failed by the suture pulling through the bone. The cortical-bone-augmentation technique never failed. In definite studies, prevention of full weight-bearing was achieved by fixation of a ten-centimeter-diameter ball under the hoof of the sheep. This led to healing in eight of ten shoulders repaired with the modified Mason-Allen stitch and cortical-bone augmentation. On histological analysis, both the simple-stitch and the modified Mason-Allen technique caused similar degrees of transient localized tissue damage. Mechanical pullout tests of repairs with the new technique showed a failure strength that was approximately 30 percent of that of an intact infraspinatus tendon at six weeks, 52 percent of that of an intact tendon at three months, and 81 percent of that of an intact tendon at six months. The repair technique with a modified Mason-Allen stitch with number-3 braided polyester suture material and cortical-bone augmentation was superior to the conventional repair technique. Use of the modified Mason-Allen stitch and the cortical-bone-augmentation device transferred the weakest point of the repair to the suture material rather than to the bone or the tendon. Failure to protect the rotator cuff post-operatively was associated with an exceedingly high rate of failure, even if optimum repair technique was used. Different techniques for rotator cuff repair substantially influence the rate of failure. A modified Mason-Allen stitch does not cause tendon necrosis, and use of this stitch with cortical-bone augmentation yields a repair that is biologically well tolerated and stronger in vivo than a repair with the conventional technique. Unprotected repairs, however, have an exceedingly high rate of failure even if optimum repair technique is used. Postoperative protection from tension overload, such as with an abduction splint, may be necessary for successful healing of massive rotator cuff tears.

  17. Ultra-high-field fMRI insights on insight: Neural correlates of the Aha!-moment.

    PubMed

    Tik, Martin; Sladky, Ronald; Luft, Caroline Di Bernardi; Willinger, David; Hoffmann, André; Banissy, Michael J; Bhattacharya, Joydeep; Windischberger, Christian

    2018-04-17

    Finding creative solutions to difficult problems is a fundamental aspect of human culture and a skill highly needed. However, the exact neural processes underlying creative problem solving remain unclear. Insightful problem solving tasks were shown to be a valid method for investigating one subcomponent of creativity: the Aha!-moment. Finding insightful solutions during a remote associates task (RAT) was found to elicit specific cortical activity changes. Considering the strong affective components of Aha!-moments, as manifested in the subjectively experienced feeling of relief following the sudden emergence of the solution of the problem without any conscious forewarning, we hypothesized the subcortical dopaminergic reward network to be critically engaged during Aha. To investigate those subcortical contributions to insight, we employed ultra-high-field 7 T fMRI during a German Version of the RAT. During this task, subjects were exposed to word triplets and instructed to find a solution word being associated with all the three given words. They were supposed to press a button as soon as they felt confident about their solution without further revision, allowing us to capture the exact event of Aha!-moment. Besides the finding on cortical involvement of the left anterior middle temporal gyrus (aMTG), here we showed for the first time robust subcortical activity changes related to insightful problem solving in the bilateral thalamus, hippocampus, and the dopaminergic midbrain comprising ventral tegmental area (VTA), nucleus accumbens (NAcc), and caudate nucleus. These results shed new light on the affective neural mechanisms underlying insightful problem solving. © 2018 The Authors Human Brain Mapping Published by Wiley Periodicals, Inc.

  18. PsyScript: a Macintosh application for scripting experiments.

    PubMed

    Bates, Timothy C; D'Oliveiro, Lawrence

    2003-11-01

    PsyScript is a scriptable application allowing users to describe experiments in Apple's compiled high-level object-oriented AppleScript language, while still supporting millisecond or better within-trial event timing (delays can be in milliseconds or refresh-based, and PsyScript can wait on external I/O, such as eye movement fixations). Because AppleScript is object oriented and system-wide, PsyScript experiments support complex branching, code reuse, and integration with other applications. Included AppleScript-based libraries support file handling and stimulus randomization and sampling, as well as more specialized tasks, such as adaptive testing. Advanced features include support for the BBox serial port button box, as well as a low-cost USB-based digital I/O card for millisecond timing, recording of any number and types of responses within a trial, novel responses, such as graphics tablet drawing, and use of the Macintosh sound facilities to provide an accurate voice key, saving voice responses to disk, scriptable image creation, support for flicker-free animation, and gaze-dependent masking. The application is open source, allowing researchers to enhance the feature set and verify internal functions. Both the application and the source are available for free download at www.maccs.mq.edu.au/-tim/psyscript/.

  19. Experimental analysis of surface finish in normal conducting cavities

    NASA Astrophysics Data System (ADS)

    Zarrebini-Esfahani, A.; Aslaninejad, M.; Ristic, M.; Long, K.

    2017-10-01

    A normal conducting 805 MHz test cavity with an in built button shaped sample is used to conduct a series of surface treatment experiments. The button enhances the local fields and influences the likelihood of an RF breakdown event. Because of their smaller sizes, compared to the whole cavity surface, they allow practical investigations of the effects of cavity surface preparation in relation to RF breakdown. Manufacturing techniques and steps for preparing the buttons to improve the surface quality are described in detail. It was observed that even after the final stage of the surface treatment, defects on the surface of the cavities still could be found.

  20. Key Aroma Compounds in Lippia dulcis (Dushi Button).

    PubMed

    Schmitt, Rainer; Cappi, Michael; Pollner, Gwendola; Greger, Veronika

    2018-03-14

    An aroma extract dilution analysis (AEDA) applied on aroma extracts prepared from the edible flower Dushi Button ( Lippia dulcis) resulted in the detection of 34 odor-active compounds. The highest flavor dilution (FD) factors were determined for methyl 2-methylbutanoate, ethyl 2-methylbutanoate, 4-mercapto-4-methyl-2-pentanone, an unknown caramel-like compound, and vanillin. Quantitative measurements performed by application of stable isotope dilution assays (SIDA), followed by a calculation of odor activity values (OAVs), resulted in the revelation of 4-mercapto-4-methyl-2-pentanone, linalool, myrcene, ethyl 2-methylbutanoate, methyl 2-methylbutanoate, and ( Z)-3-hexenal as important contributors to the flavor of Dushi Buttons.

  1. Investigations of the historic textiles excavated from Ancient Ainos (Enez - Turkey) by multiple analytical techniques

    NASA Astrophysics Data System (ADS)

    Akyuz, Sevim; Akyuz, Tanil; Cakan, Banu; Basaran, Sait

    2014-09-01

    Some metal ornamented textile specimens and a textile button, excavated from Ancient Ainos (Enez - Turkey), have been investigated using FTIR and EDXRF spectrometry, for the purpose of material identification. FTIR spectral results indicated that textiles were made from partially degummed Bombyx mori silk. The IR spectral investigation of the textile button revealed that some cellulose fillings were used inside the button. The EDXRF analysis of the metal ornaments showed that they were silver plated copper. Surface morphology of the textiles and the metal ornaments were investigated by SEM images. It was shown that textile fibers were highly degraded.

  2. Hybrid: Braking

    Science.gov Websites

    Button Stopped button highlighted subbanner graphic: gray bar STOPPED When the vehicle is stopped engine when additional power is needed. It also acts as a generator, converting energy from the engine or engine instantly when needed. Main stage: See through car with battery, engine, and electric motor

  3. Armpits, Belly Buttons and Chronic Wounds: The ABCs of Our Body Bacteria

    MedlinePlus

    ... Wounds: The ABCs of Our Body Bacteria Inside Life Science View All Articles | Inside Life Science Home Page Armpits, Belly Buttons and Chronic Wounds: ... Other Findings About Our Resident Microbes This Inside Life Science article also appears on LiveScience . Learn about related ...

  4. Optimal screw placement for base plate fixation in reverse total shoulder arthroplasty.

    PubMed

    DiStefano, James Guido; Park, Andrew Y; Nguyen, Thuc-Quyen D; Diederichs, Gerd; Buckley, Jenni M; Montgomery, William H

    2011-04-01

    Scapular cortical thickness has not been fully characterized from the perspective of determining optimal screw placement for securing the glenoid base plate in reverse shoulder arthroplasty. Twelve fresh frozen cadaveric scapulae underwent high resolution CT scans with 3-dimensional reconstructions and wall thickness analysis. Digital base plates were positioned and virtual screws were placed according to 2 scenarios: A - intraosseous through the entire course and exits a "safe region" with no known neurovascular structures; B - may leave and re-enter the bone and penetrates the thickest cortical region accessible regardless of adjacent structures. For scenario A, the optimal screw configurations were: (superior screw) length = 35 mm, 9° superior, 2° posterior; (inferior screw-A) length = 34 mm, 16° inferior, 5° anterior; (inferior screw-B) length = 31 mm, 31 inferior, 4 posterior; (posterior screw) length 19 mm, 29° inferior, 3° anterior. For scenario B: (superior screw) length = 36 mm, 28° superior, 10° anterior; (inferior screw) length = 35 mm, 19° inferior, 4° anterior; (posterior screw) length 37 mm, 23° superior, 3° anterior. The anterior screw was consistent between scenarios A and B, averaged 29 mm in length and was directed 16° inferior and 14° posterior. Thicker cortical regions were present in the lateral aspect of the suprascapular notch, scapular spine base, anterior/superior aspect of inferior pillar and junction of glenoid neck and scapular spine. Regions with high cortical thickness were accessible for both scenarios except for the posterior screw in scenario A. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  5. A new model of strabismic amblyopia: Loss of spatial acuity due to increased temporal dispersion of geniculate X-cell afferents on to cortical neurons.

    PubMed

    Crewther, D P; Crewther, S G

    2015-09-01

    Although the neural locus of strabismic amblyopia has been shown to lie at the first site of binocular integration, first in cat and then in primate, an adequate mechanism is still lacking. Here we hypothesise that increased temporal dispersion of LGN X-cell afferents driven by the deviating eye onto single cortical neurons may provide a neural mechanism for strabismic amblyopia. This idea was investigated via single cell extracellular recordings of 93 X and 50 Y type LGN neurons from strabismic and normal cats. Both X and Y neurons driven by the non-deviating eye showed shorter latencies than those driven by either the strabismic or normal eyes. Also the mean latency difference between X and Y neurons was much greater for the strabismic cells compared with the other two groups. The incidence of lagged X-cells driven by the deviating eye of the strabismic cats was higher than that of LGN X-cells from normal animals. Remarkably, none of the cells recorded from the laminae driven by the non-deviating eye were of the lagged class. A simple computational model was constructed in which a mixture of lagged and non-lagged afferents converge on to single cortical neurons. Model cut-off spatial frequencies to a moving grating stimulus were sensitive to the temporal dispersion of the geniculate afferents. Thus strabismic amblyopia could be viewed as a lack of developmental tuning of geniculate lags for neurons driven by the amblyopic eye. Monocular control of fixation by the non-deviating eye is associated with reduced incidence of lagged neurons, suggesting that in normal vision, lagged neurons might play a role in maintaining binocular connections for cortical neurons. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. An evaluation of total and inhalable samplers for the collection of wood dust in three wood products industries.

    PubMed

    Harper, Martin; Muller, Brian S

    2002-10-01

    In 1998 the American Conference for Governmental Industrial Hygienists (ACGIH) proposed size selective sampling for wood dust based on the inhalable fraction. Thus the proposed threshold limit values (TLVs) require the use of a sampler whose performance matches the inhalable convention. The Institute of Occupational Medicine (IOM) sampler has shown good agreement with the inhalable convention under controlled conditions, and the Button sampler, developed by the University of Cincinnati, has shown reasonable agreement in at least one laboratory study. The Button sampler has not been previously evaluated under wood working conditions, and the IOM has been shown to sample more mass than expected when compared to the standard closed-face cassette, which may be due to the collection of very large particles in wood working environments. Some projectile particles may be > 100 microm aerodynamic diameter and thus outside the range of the convention. Such particles, if present, can bias the estimates of concentration considerably. This study is part of an on-going research focus into selecting the most appropriate inhalable sampler for use in these industries, and to examine the impact of TLV changes. This study compared gravimetric analyses (National Institute of Occupational Safety and Health Method 0500) of side-by-side personal samples using the Button, IOM, and 37 mm closed-face cassette (CFC) under field-use conditions. A total of 51 good sample pairs were collected from three wood products industries involved in the manufacturing of cabinets, furniture, and shutters. Paired t-tests were run on each sample pair using Statistical Package for the Social Sciences (SPSS) version 10. The IOM and the CFC measured statistically different concentrations (p < 0.0005, n = 16). The IOM and Button measured statistically different concentrations (p = 0.020, n = 12). The Button and CFC did not measure statistically different concentrations of wood dust (p = 0.098, n = 23). Sampler ratios for IOM/CFC pairs ranged from 1.19-19 (median 3.35). Sampler ratios for IOM/Button pairs ranged from 0.49-163 (median 3.15). Sampler ratios for CFC/Button pairs ranged from 0.36-27 (median 1.2). In all cases, higher ratios were associated with higher concentrations. The median relative difference between the IOM's and CFC's is in accord with prior field studies in woodworking environments, and, taken together, the data imply a conversion factor greater than the 2.5 normally applied to CFC results to approximate inhalable values, as measured by the IOM. Raising the limit values by approximately 50% appears warranted for this particular situation of inhalable wood dust measured by the IOM. The IOM/Button and CFC/Button ratios were unexpectedly low, which may be due to the exclusion of very large particles, collected by the IOM and CFC samplers. Further work is required to explain these results.

  7. 78 FR 32081 - Airworthiness Directives; Aircraft Industries a.s. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-29

    ... Injection System WATER INJECTION circuit ON breakter. TCL TQ=min. 60% WATER INJECTION/ON push- Push and hold till amber button. WATER INJECTION signal comes on (on the front control panel) Before throttling back power: WATER INJECTION/OFF push- Push and check amber button. WATER INJECTION signal extinguishes...

  8. Adapting the eButton to the abilities of children for diet assessment

    USDA-ARS?s Scientific Manuscript database

    Dietary assessment is fraught with error among adults and especially among children. Innovative technology may provide more accurate assessments of dietary intake. One recently available innovative method is a camera worn on the chest (called an eButton) that takes images of whatever is in front of ...

  9. Dietary supplementation with white button mushroom augments the protective immune response to Salmonella vaccine in mice

    USDA-ARS?s Scientific Manuscript database

    We previously showed that dietary white button mushrooms (WBM) enhanced natural killer cell activity and that in vitro WBM supplementation promotes maturation and function of dendritic cells (DC). The current study investigated whether WBM consumption would enhance pathogen-specific immune response ...

  10. James Webb Telescope

    Science.gov Websites

    . solarsystem mobile thumbnail solarystem mobile button Webb will monitor the weather and atmospheres of the mobile thumbnail exoplanets-weather mobile button Webb will search for signs of life-sustaining water on planets beyond our solar system, and help us learn how planets form. blackholes mobile thumbnail

  11. The Haida Button Blanket.

    ERIC Educational Resources Information Center

    Johnson, Vesta

    In the Haida nation, there are two phratries, Eagle and Raven, divided into a number of clans sharing one or more emblems. These emblems, inherited from the mother's line, adorn the button blankets which are the traditional ceremonial robes that serve to identify the family of the wearer. Written instructions and diagrams guide students in…

  12. Two surgical approaches to fracture malunion repair.

    PubMed

    Rahal, Sheila C; Teixeira, Carlos R; Pereira-Júnior, Oduvaldo C M; Vulcano, Luiz C; Aguiar, Antonio J A; Rassy, Fabrício B

    2008-12-01

    Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-wedge corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was an adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through a bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.

  13. Pattern of Cortical Fracture following Corticotomy for Distraction Osteogenesis.

    PubMed

    Luvan, M; Kanthan, S R; Roshan, G; Saw, A

    2015-11-01

    Corticotomy is an essential procedure for deformity correction and there are many techniques described. However there is no proper classification of the fracture pattern resulting from corticotomies to enable any studies to be conducted. We performed a retrospective study of corticotomy fracture patterns in 44 patients (34 tibias and 10 femurs) performed for various indications. We identified four distinct fracture patterns, Type I through IV classification based on the fracture propagation following percutaneous corticotomy. Type I transverse fracture, Type II transverse fracture with a winglet, Type III presence of butterfly fragment and Type IV fracture propagation to a fixation point. No significant correlation was noted between the fracture pattern and the underlying pathology or region of corticotomy.

  14. Two-Photon Functional Imaging of the Auditory Cortex in Behaving Mice: From Neural Networks to Single Spines.

    PubMed

    Li, Ruijie; Wang, Meng; Yao, Jiwei; Liang, Shanshan; Liao, Xiang; Yang, Mengke; Zhang, Jianxiong; Yan, Junan; Jia, Hongbo; Chen, Xiaowei; Li, Xingyi

    2018-01-01

    In vivo two-photon Ca 2+ imaging is a powerful tool for recording neuronal activities during perceptual tasks and has been increasingly applied to behaving animals for acute or chronic experiments. However, the auditory cortex is not easily accessible to imaging because of the abundant temporal muscles, arteries around the ears and their lateral locations. Here, we report a protocol for two-photon Ca 2+ imaging in the auditory cortex of head-fixed behaving mice. By using a custom-made head fixation apparatus and a head-rotated fixation procedure, we achieved two-photon imaging and in combination with targeted cell-attached recordings of auditory cortical neurons in behaving mice. Using synthetic Ca 2+ indicators, we recorded the Ca 2+ transients at multiple scales, including neuronal populations, single neurons, dendrites and single spines, in auditory cortex during behavior. Furthermore, using genetically encoded Ca 2+ indicators (GECIs), we monitored the neuronal dynamics over days throughout the process of associative learning. Therefore, we achieved two-photon functional imaging at multiple scales in auditory cortex of behaving mice, which extends the tool box for investigating the neural basis of audition-related behaviors.

  15. [Manipulative reduction and external fixation with cardboard splint for the treatment of calcaneal fractures: a 60-case report].

    PubMed

    Hao, Bo-Chuan; Xie, Ke-Bo

    2014-07-01

    To investigate the therapeutic effects of manipulative reduction for calcaneal fractures. From January 2009 to June 2012, 53 cases (60 affected feet) of Sanders type I-IV calcaneal fractures were treated by manipulative reduction and external fixation with cardboard splint,including 45 males and 8 females with an average age of (33.5 +/- 1.54) years old ranging from 18 to 65. The course of disease ranged 0.5 h to 7 d. Before treatment the feet were swelling, ache and activity limitation in evidence, some feet were wide flat deformity, the cortical bone was broken in the imaging examination. All selected cases were evaluated using Creighton-Nebraska health foundation assessment scale for fractures of calcaneus. All cases were followed up at 12 months after treatment, 13 feet got excellent curative effect, 34 good, 11 moderate and 2 poor. Manipulative reduction for Sanders type I-IV calcaneal fractures could get excellent curative effect. Manipulative reduction for calcaneal fractures could avoid surgical trauma while assure high curative effects. Manipulative reduction is not only economical and easy therapy, but also can restore maximum function of the calcaneus with few complications and facilitate early rehabilitation of ankle and joint function.

  16. Direct chemical evidence for sphingolipid domains in the plasma membranes of fibroblasts [High-Resolution Chemical Imaging of Sphingolipid Distribution in the Plasma Membrane

    DOE PAGES

    Frisz, Jessica F.; Lou, Kaiyan; Klitzing, Haley A.; ...

    2013-01-28

    Sphingolipids play important roles in plasma membrane structure and cell signaling. Yet, their lateral distribution in the plasma membrane is poorly understood. Here we quantitatively analyzed the sphingolipid organization on the entire dorsal surface of intact cells by mapping the distribution of 15N-enriched ions from metabolically labeled 15N-sphingolipids in the plasma membrane using high-resolution imaging mass spectrometry. Many types of control experiments (internal, positive, negative, and fixation temperature), along with parallel experiments involving the imaging of fluorescent sphingolipids$-$both in living cells and during fixation of living cells$-$exclude potential artifacts. Micrometer-scale sphingolipid patches consisting of numerous 15Nsphingolipid microdomains with mean diametersmore » of ~200 nm are always present in the plasma membrane. Depletion of 30% of the cellular cholesterol did not eliminate the sphingolipid domains, but did reduce their abundance and long range organization in the plasma membrane. In contrast, disruption of the cytoskeleton eliminated the sphingolipid domains. These results indicate that these sphingolipid assemblages are not lipid rafts, and are instead a distinctly different type of sphingolipid-enriched plasma membrane domain that depends upon cortical actin.« less

  17. Green Roots: Photosynthesis and Photoautotrophy in an Underground Plant Organ.

    PubMed Central

    Flores, H. E.; Dai, Yr.; Cuello, J. L.; Maldonado-Mendoza, I. E.; Loyola-Vargas, V. M.

    1993-01-01

    The potential for photosynthetic and photoautotrophic growth was studied in hairy root cultures of Asteraceae and Solanaceae species. Upon transfer to light, initially heterotrophic root cultures of Acmella oppositifolia and Datura innoxia greened rapidly, differentiated chloroplasts, and developed light-dependent CO2 fixation in the cortical cells. Photosynthetic potential was expressed in root cultures of all the Asteraceae genera examined (Acmella, Artemisia, Rudbeckia, Stevia, and Tagetes). Hairy roots of A. oppositifolia and D. innoxia were further adapted to photoautotrophy by growing in the presence of light and added CO2 (1-5%) and by direct or sequential transfers into media containing progressively lower sugar concentrations. The transition to photoautotrophy was accompanied by an increase in CO2 fixation and in the specific activity of 1,5-ribulose-bisphosphate carboxylase/ oxygenase (Rubisco). During the adaptation of A. oppositifolia roots to photoautotrophy, the ratio of Rubisco to phosphoenolpyruvate carboxylase increased significantly, approaching that found in the leaves. The levels and patterns of alkaloids and polyacetylenes produced by Solanaceae and Asteraceae hairy roots, respectively, were dramatically altered in photomixotrophic and photoautotrophic cultures. Photoautotrophic roots of A. oppositifolia have been mainitained in vitro for over 2 years. PMID:12231691

  18. Two-Photon Functional Imaging of the Auditory Cortex in Behaving Mice: From Neural Networks to Single Spines

    PubMed Central

    Li, Ruijie; Wang, Meng; Yao, Jiwei; Liang, Shanshan; Liao, Xiang; Yang, Mengke; Zhang, Jianxiong; Yan, Junan; Jia, Hongbo; Chen, Xiaowei; Li, Xingyi

    2018-01-01

    In vivo two-photon Ca2+ imaging is a powerful tool for recording neuronal activities during perceptual tasks and has been increasingly applied to behaving animals for acute or chronic experiments. However, the auditory cortex is not easily accessible to imaging because of the abundant temporal muscles, arteries around the ears and their lateral locations. Here, we report a protocol for two-photon Ca2+ imaging in the auditory cortex of head-fixed behaving mice. By using a custom-made head fixation apparatus and a head-rotated fixation procedure, we achieved two-photon imaging and in combination with targeted cell-attached recordings of auditory cortical neurons in behaving mice. Using synthetic Ca2+ indicators, we recorded the Ca2+ transients at multiple scales, including neuronal populations, single neurons, dendrites and single spines, in auditory cortex during behavior. Furthermore, using genetically encoded Ca2+ indicators (GECIs), we monitored the neuronal dynamics over days throughout the process of associative learning. Therefore, we achieved two-photon functional imaging at multiple scales in auditory cortex of behaving mice, which extends the tool box for investigating the neural basis of audition-related behaviors. PMID:29740289

  19. Neural mechanisms of eye contact when listening to another person talking

    PubMed Central

    Borowiak, Kamila; Tudge, Luke; Otto, Carolin; von Kriegstein, Katharina

    2017-01-01

    Abstract Eye contact occurs frequently and voluntarily during face-to-face verbal communication. However, the neural mechanisms underlying eye contact when it is accompanied by spoken language remain unexplored to date. Here we used a novel approach, fixation-based event-related functional magnetic resonance imaging (fMRI), to simulate the listener making eye contact with a speaker during verbal communication. Participants’ eye movements and fMRI data were recorded simultaneously while they were freely viewing a pre-recorded speaker talking. The eye tracking data were then used to define events for the fMRI analyses. The results showed that eye contact in contrast to mouth fixation involved visual cortical areas (cuneus, calcarine sulcus), brain regions related to theory of mind/intentionality processing (temporoparietal junction, posterior superior temporal sulcus, medial prefrontal cortex) and the dorsolateral prefrontal cortex. In addition, increased effective connectivity was found between these regions for eye contact in contrast to mouth fixations. The results provide first evidence for neural mechanisms underlying eye contact when watching and listening to another person talking. The network we found might be well suited for processing the intentions of communication partners during eye contact in verbal communication. PMID:27576745

  20. Tibiotalocalcaneal arthrodesis using a dynamically locked retrograde intramedullary nail.

    PubMed

    Pelton, Kevin; Hofer, Jason K; Thordarson, David B

    2006-10-01

    Tibiotalocalcaneal arthrodesis is an important salvage method for patients with complex hindfoot problems, including Charcot arthropathy, osteonecrosis of the talus, combined arthritis of the ankle and subtalar joint, and failed total ankle arthroplasty. This study evaluated the results of a dynamic retrograde intramedullary nail for fixation with posterior to anterior distal interlocking screws placed through the calcaneus for tibiotalocalcaneal fusion. Thirty-three consecutive tibiotalocalcaneal fusions were done by a single surgeon (DBT) and were stabilized with a dynamic retrograde intramedullary nail. Time to fusion, impaction of the nail relative to the intramedullary canal, nail-tibial angle, and complications were noted. Average followup was 14 months. Twenty-nine of 33 feet (88%) fused at an average of 3.7 months after surgery. Average impaction of the nail was 2.3 (0.5 to 5.0) mm. Cortical hypertrophy at the tip of the rod or at the proximal interlocking screw was noted in 13 of 27 patients. A trend toward a higher nonunion rate was noted in patients with an increased nail-tibial angle. Dynamic retrograde intramedullary nailing for fixation of the tibiotalocalcaneal fusions is a good method of stabilizing this complex fusion construct.

  1. Surgical repair of propagating condylar fractures of the third metacarpal/metatarsal bones with cortical screws placed in lag fashion in 26 racehorses (2007-2015).

    PubMed

    Moulin, N; François, I; Coté, N; Alford, C; Cleary, O; Desjardins, M R

    2018-01-19

    Despite the recommendation of plate fixation for propagating condylar fractures of the third metacarpal (McIII) or third metatarsal bone (MtIII), lag screw fixation can be a viable surgical option. To evaluate short-term outcome and long-term racing performance of horses that underwent lag screw fixation of long condylar fractures of the McIII/MtIII. Retrospective case series. Medical records, post-surgical racing performance and outcome of 26 horses with propagating fractures of the medial and/or lateral condyle of McIII/MtIII were reviewed. Medical information included were age, breed, sex, physical examination at admission, circumstances of fracture, radiographic evaluation, anaesthesia and recovery records, surgical and post-operative management, as well as complications. Outcome included racing data and information from telephone interviews. Twenty-six horses (9 Standardbreds and 17 Thoroughbreds) were admitted with a long condylar fracture of the McIII/MtIII. Fore- and hindlimbs were equally represented with the left hindlimb being more frequently involved. Most of the fractures had a spiralling component (76%) and four (15%) were comminuted. Fifteen (58%) horses raced post-surgery including nine Standardbreds (100%) and six Thoroughbreds (35%). Twelve of them were placed in at least one race and 11 won at least once. One horse sustained a severe complication in recovery. No significant difference was observed in the racing performances before and after surgery. Follow-up method and duration were not standardised and there is a low number of cases with six surgeons. Long condylar fractures can be repaired using lag fashion technique combined with a half-limb or full-limb tight cast for recovery as a good surgical alternative. Similar results to plate fixation can be expected, with a return to racing of more than 50%, and the prognosis being even better for pacers. © 2018 EVJ Ltd.

  2. Radiographic study of the fifth metatarsal for optimal intramedullary screw fixation of Jones fracture.

    PubMed

    Ochenjele, George; Ho, Bryant; Switaj, Paul J; Fuchs, Daniel; Goyal, Nitin; Kadakia, Anish R

    2015-03-01

    Jones fractures occur in the relatively avascular metadiaphyseal junction of the fifth metatarsal (MT), which predisposes these fractures to delayed union and nonunion. Operative treatment with intramedullary (IM) screw fixation is recommended in certain cases. Incorrect screw selection can lead to refractures, nonunion, and cortical blowout fractures. A better understanding of the anatomy of the fifth MT could aid in preoperative planning, guide screw size selection, and minimize complications. We retrospectively identified foot computed tomographic (CT) scans of 119 patients that met inclusion criteria. Using interactive 3-dimensional (3-D) models, the following measurements were calculated: MT length, "straight segment length" (distance from the base of the MT to the shaft curvature), and canal diameter. The diaphysis had a lateroplantar curvature where the medullary canal began to taper. The average straight segment length was 52 mm, and corresponded to 68% of the overall length of the MT from its proximal end. The medullary canal cross-section was elliptical rather than circular, with widest width in the sagittal plane and narrowest in coronal plane. The average coronal canal diameter at the isthmus was 5.0 mm. A coronal diameter greater than 4.5 mm at the isthmus was present in 81% of males and 74% of females. To our knowledge, this is the first anatomic description of the fifth metatarsal based on 3-D imaging. Excessive screw length could be avoided by keeping screw length less than 68% of the length of the fifth metatarsal. A greater than 4.5 mm diameter screw might be needed to provide adequate fixation for most study patients since the isthmus of the medullary canal for most were greater than 4.5 mm. Our results provide an improved understanding of the fifth metatarsal anatomy to guide screw diameter and length selection to maximize screw fixation and minimize complications. © The Author(s) 2014.

  3. The Button Project

    ERIC Educational Resources Information Center

    Armstrong, Charley

    2005-01-01

    In this article, the author describes The Button Project. It started as a dream, a need to educate future generations about the Holocaust, to teach tolerance, and to remember the past. Under the auspices of the Jewish Federation of Peoria, a small band of people joined together with the goal of teaching people about the Holocaust so that it will…

  4. Utility of eButton images for identifying food preparation behaviors and meal-related tasks in adolescents

    USDA-ARS?s Scientific Manuscript database

    Food preparation skills may encourage healthy eating. Traditional assessment of child food preparation employs self- or parent proxy-reporting methods, which are prone to error. The eButton is a wearable all-day camera that has promise as an objective, passive method for measuring child food prepara...

  5. 31. VIEW OF A WORKER HOLDING A PLUTONIUM 'BUTTON.' PLUTONIUM, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    31. VIEW OF A WORKER HOLDING A PLUTONIUM 'BUTTON.' PLUTONIUM, A MAN-MADE SUBSTANCE, WAS RARE. SCRAPS RESULTING FROM PRODUCTION AND PLUTONIUM RECOVERED FROM RETIRED NUCLEAR WEAPONS WERE REPROCESSED INTO VALUABLE PURE-PLUTONIUM METAL (9/19/73). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO

  6. "Urgency tip": a portable patient-activated device for objective measurement of urinary urgency.

    PubMed

    Kobayashi, Hideki; Araki, Isao; Tsuchida, Takayuki; Zakoji, Hidenori; Mikami, Yuki; Takeda, Masayuki; Kiyohiro, Noriaki

    2007-03-01

    For clinical practice and research of overactive bladder syndrome, it is essential to evaluate urgency symptoms in daily life. We have developed a portable patient-activated device to record bladder sensations. This electronic device is pocket-size and light, with five grading buttons and another button for cancellation.

  7. 46 CFR 121.510 - Recommended emergency broadcast instructions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Immediate Danger to Life or Property. (4) Say: “THIS IS (INSERT VESSEL'S NAME), (INSERT VESSEL'S NAME), (INSERT VESSEL'S NAME), (INSERT VESSEL'S CALL SIGN), OVER.” (5) Release the microphone button briefly and... 16 VHF and 2182 kHz on SSB are for emergency and calling purposes only.) (3) Press microphone button...

  8. Harvesting keratolimbal allografts from corneoscleral buttons: a novel application of cyanoacrylate adhesive.

    PubMed

    Lim, L T; Bhatt, P R; Ramaesh, K

    2008-11-01

    To describe an alternative and novel technique using cyanoacrylate glue to achieve successful limbal tissue dissection, from an organ culture media stored corneoscleral button, without an artificial anterior chamber. A donor corneoscleral button (leftover from penetrating keratoplasty) was divided into two equal semicircular halves. A thick layer of tissue adhesive (N-butyl-2-cyanoacrylate) was spread on a sterile rubber block (the under surface of the donor punch). One half of the donor corneoscleral rim was placed epithelial side up on the adhesive and allowed to attach firmly to the block. This composite provided stability to the donor rim allowing lamellar dissection of the limbal tissue to be performed without damaging the limbal epithelium. Regular, partial-thickness limbal tissue was obtained. There was no histological evidence of glue or cellular toxicity of the harvested limbal stem cells. This harvested tissue had been grafted successfully in patients with limbal stem cell deficiency also undergoing keratoplasty. Tissue adhesive can be a simple, effective and useful tool in the dissection and harvesting of corneal limbal stem cell allografts from corneoscleral buttons stored in organ culture media.

  9. Enhancing stability of essential oils by microencapsulation for preservation of button mushroom during postharvest

    PubMed Central

    Alikhani-Koupaei, Majid; Mazlumzadeh, Meisam; Sharifani, Mohamadmehdi; Adibian, Mohamad

    2014-01-01

    Fresh button mushrooms (Agaricus bisporus L.) are sensitive to browning, water loss, and microbial attack. The short shelf-life of mushrooms is an impediment to the distribution and marketing of the fresh product. Essential oils outstand as an alternative to chemical preservatives and their use in foods meets the demands of consumers for natural products. To resolve controlled release of oil and increase in antioxidant and antimicrobial activities, the oil was incorporated into microcapsules. Effects of microcapsulated thyme (Thymus vulgaris L.) and rosemary (Rosmarinus officinalis L.) on quality of fresh button mushroom were compared. Physicochemical qualities were evaluated during 15 days of storage at 4 ± 0.5°C. All treatments prevented product weight loss and decrease in polyphenoloxidase and peroxidase activities during storage. Color and firmness, microbiological analysis, and total phenolic content caused the least change. With use of microencapsulated oils, mushrooms were within acceptable limits during 10 days of storage. Microencapsulated rosemary oil produced the highest beneficial effects and has potential to improve quality of button mushrooms and extend shelf-life. PMID:25473510

  10. Further miniaturisation of the Thermochron iButton to create a thermal bio-logger weighing 0.3 g.

    PubMed

    Virens, Josef; Cree, Alison

    2018-06-05

    Thermochron iButtons are commonly used by thermal biologists to continuously measure body temperature from animals. However, if unmodified, these devices are of a size that limits their use with very small animals. To allow iButtons to be used to study smaller species, methods to miniaturise them by 61% have been previously described. We present a method to reduce iButton mass by a further 71%. The modified devices have a shorter battery life, but the minimum size of vertebrates able to carry the devices is reduced from 28.9 g to 6.6 g, if the arbitrary, yet widely cited, maximum of 5% body mass for attached devices is adhered to. We demonstrate the application of our method by recording surface temperatures of captive and wild skinks and show that captive cockroaches weighing 0.8 g are also able to carry the device. We believe this to be the first time that temperature data have been recorded from an insect in this way. © 2018. Published by The Company of Biologists Ltd.

  11. Independent Suture Tape Reinforcement of Small and Standard Diameter Grafts for Anterior Cruciate Ligament Reconstruction: A Biomechanical Full Construct Model.

    PubMed

    Bachmaier, Samuel; Smith, Patrick A; Bley, Jordan; Wijdicks, Coen A

    2018-02-01

    To compare the dynamic elongation, stiffness behavior, and ultimate failure load of standard with small diameter soft tissue grafts for anterior cruciate ligament (ACL) reconstruction with and without high-strength suture tape reinforcement. Both a tripled "small" diameter and a "standard" quadrupled tendon graft with and without suture tape reinforcement were tested using suspensory fixation (n = 8 each group). The suture tape was passed through the suspensory fixation button on the femur and tibia to ensure independent (safety belt) fixation from the graft in vitro. The testing of the constructs included position-controlled cyclic loading, force-controlled cyclic loading at 250 N and 400 N as well as pull to failure (50 mm/min). Reinforcement of a small diameter graft significantly reduced dynamic elongation of 38% (1.46 ± 0.28 mm vs 2.34 ± 0.44 mm, P < .001) and 50% (2.55 ± 0.44 mm vs 5.06 ± 0.67 mm, P < .001) after the 250 N and 400 N load protocol, respectively. Reinforcement of a standard diameter tendon graft decreased dynamic elongation of 15% (1.59 ± 0.34 mm vs 1.86 ± 0.17 mm, P = .066) and 26% (2.62 ± 0.44 mm vs 3.55 ± 0.44 mm, P < .001). No significant difference was found between both reinforced models. The ultimate failure loads of small and standard diameter reinforced grafts were 1592 ± 105 N and 1585 ± 265 N, resulting in a 64% (P < .001) and 40% (P < .001) increase compared with their respective controls. Independent suture tape reinforcement of soft tissue grafts for ACL reconstruction leads to significantly reduced elongation and higher ultimate failure load according to in vivo native ACL function data without stress-shielding the soft tissue graft. If in vitro results are translational to human knees in vivo, the suture tape reinforcement technique for ACL reconstruction may decrease the risk of graft tears, particularly in the case of small diameter soft tissue grafts. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Aniridia-related keratopathy: Structural changes in naïve and transplanted corneal buttons

    PubMed Central

    Stenevi, Ulf; Pedrosa Domellöf, Fátima

    2018-01-01

    Background To study structural changes in naïve and surgically treated corneas of aniridia patients with advanced aniridia-related keratopathy (ARK). Methods and findings Two naïve corneal buttons from patients with advanced ARK submitted to penetrating keratoplasty for the first time, one corneal button from an ARK patient that had undergone a keratolimbal allograft (KLAL), two corneal buttons from ARK patients who had previously undergone centered or decentered transplantation and were now retransplanted and two adult healthy donor control corneas were processed for immunohistochemistry. Antibodies against extracellular matrix components in the stroma and in the epithelial basement membrane (collagen I and IV, collagen receptor α11 integrin and laminin α3 chain), markers of fibrosis, wound healing and vascularization (fibronectin, tenascin-C, vimentin, α-SMA and caveolin-1), cell division (Ki-67) and macrophages (CD68) were used. Naïve ARK, KLAL ARK corneas and transplanted corneal buttons presented similar histopathological changes with irregular epithelium and disruption or absence of epithelial basal membrane. There was a loss of the orderly pattern of collagen lamellae and absence of collagen I in all ARK corneas. Vascularization was revealed by the presence of caveolin-1 and collagen IV in the pannus of all ARK aniridia corneas. The changes observed in decentered and centered transplants were analogous. Conclusions Given the similar pathological features of all cases, conditions inherent to the host seem to play an important role on the pathophysiology of the ARK in the long run. PMID:29889891

  13. Aniridia-related keratopathy: Structural changes in naïve and transplanted corneal buttons.

    PubMed

    Vicente, André; Byström, Berit; Lindström, Mona; Stenevi, Ulf; Pedrosa Domellöf, Fátima

    2018-01-01

    To study structural changes in naïve and surgically treated corneas of aniridia patients with advanced aniridia-related keratopathy (ARK). Two naïve corneal buttons from patients with advanced ARK submitted to penetrating keratoplasty for the first time, one corneal button from an ARK patient that had undergone a keratolimbal allograft (KLAL), two corneal buttons from ARK patients who had previously undergone centered or decentered transplantation and were now retransplanted and two adult healthy donor control corneas were processed for immunohistochemistry. Antibodies against extracellular matrix components in the stroma and in the epithelial basement membrane (collagen I and IV, collagen receptor α11 integrin and laminin α3 chain), markers of fibrosis, wound healing and vascularization (fibronectin, tenascin-C, vimentin, α-SMA and caveolin-1), cell division (Ki-67) and macrophages (CD68) were used. Naïve ARK, KLAL ARK corneas and transplanted corneal buttons presented similar histopathological changes with irregular epithelium and disruption or absence of epithelial basal membrane. There was a loss of the orderly pattern of collagen lamellae and absence of collagen I in all ARK corneas. Vascularization was revealed by the presence of caveolin-1 and collagen IV in the pannus of all ARK aniridia corneas. The changes observed in decentered and centered transplants were analogous. Given the similar pathological features of all cases, conditions inherent to the host seem to play an important role on the pathophysiology of the ARK in the long run.

  14. Utility of eButton images for identifying food preparation behaviors and meal-related tasks in adolescents.

    PubMed

    Raber, Margaret; Patterson, Monika; Jia, Wenyan; Sun, Mingui; Baranowski, Tom

    2018-02-24

    Food preparation skills may encourage healthy eating. Traditional assessment of child food preparation employs self- or parent proxy-reporting methods, which are prone to error. The eButton is a wearable all-day camera that has promise as an objective, passive method for measuring child food preparation practices. This paper explores the feasibility of the eButton to reliably capture home food preparation behaviors and practices in a sample of pre- and early adolescents (ages 9 to 13). This is a secondary analysis of two eButton pilot projects evaluating the dietary intake of pre- and early adolescents in or around Houston, Texas. Food preparation behaviors were coded into seven major categories including: browsing, altering food/adding seasoning, food media, meal related tasks, prep work, cooking and observing. Inter-coder reliability was measured using Cohen's kappa and percent agreement. Analysis was completed on data for 31 participants. The most common activity was browsing in the pantry or fridge. Few participants demonstrated any food preparation work beyond unwrapping of food packages and combining two or more ingredients; actual cutting or measuring of foods were rare. Although previous research suggests children who "help" prepare meals may obtain some dietary benefit, accurate assessment tools of food preparation behavior are lacking. The eButton offers a feasible approach to food preparation behavior measurement among pre- and early adolescents. Follow up research exploring the validity of this method in a larger sample, and comparisons between cooking behavior and dietary intake are needed.

  15. Figure-ground processing during fixational saccades in V1: indication for higher-order stability.

    PubMed

    Gilad, Ariel; Pesoa, Yair; Ayzenshtat, Inbal; Slovin, Hamutal

    2014-02-26

    In a typical visual scene we continuously perceive a "figure" that is segregated from the surrounding "background" despite ongoing microsaccades and small saccades that are performed when attempting fixation (fixational saccades [FSs]). Previously reported neuronal correlates of figure-ground (FG) segregation in the primary visual cortex (V1) showed enhanced activity in the "figure" along with suppressed activity in the noisy "background." However, it is unknown how this FG modulation in V1 is affected by FSs. To investigate this question, we trained two monkeys to detect a contour embedded in a noisy background while simultaneously imaging V1 using voltage-sensitive dyes. During stimulus presentation, the monkeys typically performed 1-3 FSs, which displaced the contour over the retina. Using eye position and a 2D analytical model to map the stimulus onto V1, we were able to compute FG modulation before and after each FS. On the spatial cortical scale, we found that, after each FS, FG modulation follows the stimulus retinal displacement and "hops" within the V1 retinotopic map, suggesting visual instability. On the temporal scale, FG modulation is initiated in the new retinotopic position before it disappeared from the old retinotopic position. Moreover, the FG modulation developed faster after an FS, compared with after stimulus onset, which may contribute to visual stability of FG segregation, along the timeline of stimulus presentation. Therefore, despite spatial discontinuity of FG modulation in V1, the higher-order stability of FG modulation along time may enable our stable and continuous perception.

  16. Encoding of Target Detection during Visual Search by Single Neurons in the Human Brain.

    PubMed

    Wang, Shuo; Mamelak, Adam N; Adolphs, Ralph; Rutishauser, Ueli

    2018-06-08

    Neurons in the primate medial temporal lobe (MTL) respond selectively to visual categories such as faces, contributing to how the brain represents stimulus meaning. However, it remains unknown whether MTL neurons continue to encode stimulus meaning when it changes flexibly as a function of variable task demands imposed by goal-directed behavior. While classically associated with long-term memory, recent lesion and neuroimaging studies show that the MTL also contributes critically to the online guidance of goal-directed behaviors such as visual search. Do such tasks modulate responses of neurons in the MTL, and if so, do their responses mirror bottom-up input from visual cortices or do they reflect more abstract goal-directed properties? To answer these questions, we performed concurrent recordings of eye movements and single neurons in the MTL and medial frontal cortex (MFC) in human neurosurgical patients performing a memory-guided visual search task. We identified a distinct population of target-selective neurons in both the MTL and MFC whose response signaled whether the currently fixated stimulus was a target or distractor. This target-selective response was invariant to visual category and predicted whether a target was detected or missed behaviorally during a given fixation. The response latencies, relative to fixation onset, of MFC target-selective neurons preceded those in the MTL by ∼200 ms, suggesting a frontal origin for the target signal. The human MTL thus represents not only fixed stimulus identity, but also task-specified stimulus relevance due to top-down goal relevance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. The engagement of cortical areas preceding exogenous vergence eye movements.

    PubMed

    Wojtczak-Kwaśniewska, Monika; Przekoracka-Krawczyk, Anna; Van der Lubbe, Rob H J

    2018-01-01

    Source analyses on event related potentials (ERPs) derived from the electroencephalogram (EEG) were performed to examine the respective roles of cortical areas preceding exogenously triggered saccades, combined convergences, and combined divergences. All eye movements were triggered by the offset of a central fixation light emitting diode (LED) and the onset of a lateral LED at various depths in an otherwise fully darkened room. Our analyses revealed that three source pairs, two located in the frontal lobe-the frontal eye fields (FEF) and an anterior frontal area-, and one located within the occipital cortex, can account for 99.2% of the observed ERPs. Overall, the comparison between source activities revealed the largest activity in the occipital cortex, while no difference in activity between FEF and the anterior frontal area was obtained. For all sources, increased activity was observed for combined vergences, especially combined convergences, relative to saccades. Behavioral results revealed that onset latencies were longest for combined convergences, intermediate for combined divergences, and the shortest for saccades. Together, these findings fit within a perspective in which both occipital and frontal areas play an important role in retinal disparity detection. In the case of saccades and combined divergences stimulus-locked activity was larger than response-locked activity, while no difference between stimulus- and response-locked activity was observed for combined convergences. These findings seem to imply that the electrophysiological activity preceding exogenous eye movements consists of a sensory-related part that is under cortical control, while subcortical structures may be held responsible for final execution.

  18. Ethanol-induced disruption of Golgi apparatus morphology, primary neurite number and cellular orientation in developing cortical neurons

    PubMed Central

    Powrozek, Teresa A.; Olson, Eric C.

    2012-01-01

    Prenatal ethanol exposure disrupts cortical neurite initiation and outgrowth, but prior studies have reported both ethanol-dependent growth promotion and inhibition. To resolve this ambiguity and better approximate in vivo conditions, we quantitatively analyzed neuronal morphology using a new, whole hemisphere explant model. In this model, Layer 6 (L6) cortical neurons migrate, laminate and extend neurites in an organotypic fashion. To selectively label L6 neurons we performed ex utero electroporation of a GFP expression construct at embryonic day 13 and allowed the explants to develop for 2 days in vitro. Explants were exposed to (400mg/dL) ethanol for either 4 or 24 hrs prior to fixation. Complete 3-D reconstructions were made of >80 GFP-positive neurons in each experimental condition. Acute responses to ethanol exposure included compaction of the Golgi apparatus accompanied by elaboration of supernumerary primary apical neurites, as well as a modest (~15%) increase in higher order apical neurite length. With longer exposure time, ethanol exposure leads to a consistent, significant disorientation of the cell (cell body, primary apical neurite, and Golgi) with respect to the pial surface. The effects on cellular orientation were accompanied by decreased expression of cytoskeletal elements, microtubule associated protein 2 and F-actin. These findings indicate that upon exposure to ethanol, developing L6 neurons manifest disruptions in Golgi apparatus and cytoskeletal elements which may in turn trigger selective and significant perturbations to primary neurite formation and neuronal polarity. PMID:22840816

  19. Management of acute unstable distal clavicle fracture with a modified coracoclavicular stabilization technique using a bidirectional coracoclavicular loop system.

    PubMed

    Kanchanatawan, Wichan; Wongthongsalee, Ponrachai

    2016-02-01

    Fracture of the distal clavicle is not uncommon. Despite the vast literature available for the management of this fracture, there is no consensus regarding the gold standard treatment for this fracture. To assess the clinical and radiographic outcomes and complications of acute unstable distal clavicle fracture when treated by a modified coracoclavicular stabilization technique using a bidirectional coracoclavicular loop system. Thirty-nine patients (32 males, 7 females) with acute unstable distal clavicle fractures treated by modified coracoclavicular stabilization using the surgical technique of bidirectional coracoclavicular (CC) loops seated behind the coracoacromial (CA) ligament were retrospectively reviewed. Mean follow-up time was 35.7 months (range 24-47 months). The outcomes measured included union rate, union time, CC distances when compared to the patients' uninjured shoulders, and the Constant and ASES shoulder scores, which were evaluated 6 months after surgery. All fractures displayed clinical union within 13 weeks postoperatively. The mean union time was 9.2 weeks (range 7-13 weeks). At the time of union, the CC distances on the affected shoulders were on average 0.9 mm (range 0-1.6 mm) longer than the unaffected shoulders. At 6 months after surgery, the Constant and ASES scores were on average 93.4 (72-100) and 91.5 (75-100), respectively. No complications related to the fixation loops, musculocutaneous nerve injuries, or fractures of coracoid or clavicle were recorded. One case of surgical wound dehiscence was observed due to superficial infection. Enlargement of the clavicle drill hole without migration of the buttons was observed in 9 out of 16 cases at a follow-up time of at least 30 months after the original operation. Modified CC stabilization using bidirectional CC loops seated behind the CA ligament is a simple surgical technique that naturally restores stability to the distal clavicle fracture. It also produces predictable outcomes, a high union rate, good to excellent shoulder function, and a low complication rate. The buttons and suture loops were routinely removed in a second operation in order to prevent late stress fracture of the clavicle.

  20. Napoleon's Buttons: Teaching the Role of Chemistry in History

    ERIC Educational Resources Information Center

    Samet, Cindy; Higgins, Pamela J.

    2005-01-01

    A course designed on the theme of Napoleon's Buttons, which states that there is a connection between the chemical structure of a compound and its pivotal moments in history affecting the development of society is explained. Students liked the book choice for the course because the focus was not on straight chemistry, but the intersection of…

  1. Designing a Machinery Control System (MCS) Security Testbed

    DTIC Science & Technology

    2014-09-01

    IO LAB” button and verify the display looks as follows: 95 Figure F22 . “Ready State” (and start state)of the DIOL as displayed at the HMI...After verification that the HMI screen looks like Figure F22 , click on the “Back to Home Screen” button and return to the HMI “Home” screen as seen

  2. 78 FR 66099 - Qualification of Drivers; Exemption Applications; Vision

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-04

    ... every year (a) by an ophthalmologist or optometrist who attests that the vision in the better eye... showing that the vision in the better eye continues to meet the requirement specified at 49 CFR 391.41(b... click the search button. When the new screen appears, click on the blue ``Comment Now!'' button on the...

  3. Peach fruit set and buttoning after spring frost

    USDA-ARS?s Scientific Manuscript database

    A spring frost occurred on 29 Mar. 2015 at the USDA-ARS Byron station after three weeks of blooming when most fruitlets were forming. Due to severe fruitlet drop, the overall fruit set on a scale of 0-9 was substantially reduced, from 5.61 averaged in 2014 to 2.61 in 2015. In addition, buttons (abno...

  4. Mechanical Design of Metal Dome for Industrial Application

    NASA Astrophysics Data System (ADS)

    Jin-Chee Liu, Thomas; Chen, Li-Wei; Lin, Nai-Pin

    2018-02-01

    In this paper, the mechanical design of metal domes is studied using finite element analysis. The snap-through behavior of a practical button design that uses a metal dome is found. In addition, the individual click ratio and maximum force for a variety of metal domes are determined. This paper provides guidance on button design for industrial engineers.

  5. Tube support

    DOEpatents

    Mullinax, Jerry L.

    1988-01-01

    A tube support for supporting horizontal tubes from an inclined vertical support tube passing between the horizontal tubes. A support button is welded to the vertical support tube. Two clamping bars or plates, the lower edges of one bearing on the support button, are removably bolted to the inclined vertical tube. The clamping bars provide upper and lower surface support for the horizontal tubes.

  6. The Newport Button: The Large Scale Replication Of Combined Three-And Two-Dimensional Holographic Images

    NASA Astrophysics Data System (ADS)

    Cowan, James J.

    1984-05-01

    A unique type of holographic imagery and its large scale replication are described. The "Newport Button", which was designed as an advertising premium item for the Newport Corporation, incorporates a complex overlay of holographic diffraction gratings surrounding a three-dimensional holographic image of a real object. The combined pattern is recorded onto a photosensitive medium from which a metal master is made. The master is subsequently used to repeatedly emboss the pattern into a thin plastic sheet. Individual patterns are then die cut from the metallized plastic and mounted onto buttons. A discussion is given of the diffraction efficiencies of holograms made in this particular fashion and of the special requirements of the replication process.

  7. Language-motor interference reflected in MEG beta oscillations.

    PubMed

    Klepp, Anne; Niccolai, Valentina; Buccino, Giovanni; Schnitzler, Alfons; Biermann-Ruben, Katja

    2015-04-01

    The involvement of the brain's motor system in action-related language processing can lead to overt interference with simultaneous action execution. The aim of the current study was to find evidence for this behavioural interference effect and to investigate its neurophysiological correlates using oscillatory MEG analysis. Subjects performed a semantic decision task on single action verbs, describing actions executed with the hands or the feet, and abstract verbs. Right hand button press responses were given for concrete verbs only. Therefore, longer response latencies for hand compared to foot verbs should reflect interference. We found interference effects to depend on verb imageability: overall response latencies for hand verbs did not differ significantly from foot verbs. However, imageability interacted with effector: while response latencies to hand and foot verbs with low imageability were equally fast, those for highly imageable hand verbs were longer than for highly imageable foot verbs. The difference is reflected in motor-related MEG beta band power suppression, which was weaker for highly imageable hand verbs compared with highly imageable foot verbs. This provides a putative neuronal mechanism for language-motor interference where the involvement of cortical hand motor areas in hand verb processing interacts with the typical beta suppression seen before movements. We found that the facilitatory effect of higher imageability on action verb processing time is perturbed when verb and motor response relate to the same body part. Importantly, this effect is accompanied by neurophysiological effects in beta band oscillations. The attenuated power suppression around the time of movement, reflecting decreased cortical excitability, seems to result from motor simulation during action-related language processing. This is in line with embodied cognition theories. Copyright © 2015. Published by Elsevier Inc.

  8. How preschoolers and adults represent their joint action partner's behavior.

    PubMed

    Sacheli, Lucia Maria; Meyer, M; Hartstra, E; Bekkering, H; Hunnius, S

    2017-10-24

    We investigated the cognitive mechanisms underlying turn-taking joint action in 42-month-old children (Experiment 1) and adults (Experiment 2) using a behavioral task of dressing a virtual bear together. We aimed to investigate how participants represent a partners' behavior, i.e., in terms of specific action kinematics or of action effects. The bear was dressed by pressing a smaller and a bigger button. In the Action-response task, instructions asked participants to respond to the partner by pressing the same or opposite button; in the Action-effect task they had to respond to the partner's action effect by dressing the bear with the lacking part of the clothing, which in some cases implied pressing the same button and in other cases implied pressing the opposite button. In 50% of the trials, the partner's association between each button and the ensuing effect (dressing the bear with t-shirt or pants) was reversed, while it never changed for participants. Both children and adults showed no effect of physical congruency of actions, but showed impaired performance in the Action-effect task if their partner achieved her effect through a different action-effect association than their own. These results suggest that, when encoding their partner's actions, agents are influenced by action-effect associations that they learnt through their own experience. While interference led to overt errors in children, it caused longer reaction times in adults, suggesting that a flexible cognitive control (that is still in development in young children) is required to take on the partner's perspective.

  9. Automatic food detection in egocentric images using artificial intelligence technology.

    PubMed

    Jia, Wenyan; Li, Yuecheng; Qu, Ruowei; Baranowski, Thomas; Burke, Lora E; Zhang, Hong; Bai, Yicheng; Mancino, Juliet M; Xu, Guizhi; Mao, Zhi-Hong; Sun, Mingui

    2018-03-26

    To develop an artificial intelligence (AI)-based algorithm which can automatically detect food items from images acquired by an egocentric wearable camera for dietary assessment. To study human diet and lifestyle, large sets of egocentric images were acquired using a wearable device, called eButton, from free-living individuals. Three thousand nine hundred images containing real-world activities, which formed eButton data set 1, were manually selected from thirty subjects. eButton data set 2 contained 29 515 images acquired from a research participant in a week-long unrestricted recording. They included both food- and non-food-related real-life activities, such as dining at both home and restaurants, cooking, shopping, gardening, housekeeping chores, taking classes, gym exercise, etc. All images in these data sets were classified as food/non-food images based on their tags generated by a convolutional neural network. A cross data-set test was conducted on eButton data set 1. The overall accuracy of food detection was 91·5 and 86·4 %, respectively, when one-half of data set 1 was used for training and the other half for testing. For eButton data set 2, 74·0 % sensitivity and 87·0 % specificity were obtained if both 'food' and 'drink' were considered as food images. Alternatively, if only 'food' items were considered, the sensitivity and specificity reached 85·0 and 85·8 %, respectively. The AI technology can automatically detect foods from low-quality, wearable camera-acquired real-world egocentric images with reasonable accuracy, reducing both the burden of data processing and privacy concerns.

  10. Spicing Things up by Adding Color and Relieving Pain: The Use of "Napoleon's Buttons" in Organic Chemistry

    ERIC Educational Resources Information Center

    Bucholtz, Kevin M.

    2011-01-01

    For some students, organic chemistry can be a distant subject and unrelated to any courses they have seen in their college careers. To develop a more contextual learning experience in organic chemistry, an additional text, "Napoleon's Buttons: 17 Molecules That Changed History," by Penny Le Couteur and Jay Burreson, was incorporated as a…

  11. Miniature Two-Axis Joystick Controller

    NASA Technical Reports Server (NTRS)

    Hollow, R.

    1983-01-01

    Novel movable-button-actuated self-centering controller uses optoelectronics to produce X and Y signals for aircraft control. In addition to be extremely compact, device puts our voltages having high signal-to-noise ratio, especially at critical center position where in many controllers this ratio is poorest. Combination of new saddle-shaped button and positive centering gives "feel" and "breakout" met with pilot approval.

  12. --No Title--

    Science.gov Websites

    :#ccc;text-align:center;padding:5px}.upper_button{text-align:right;padding-bottom:5px}.side_button[type ;width:175px;text-align:left;font-weight:bold;overflow:hidden}.left_head_title_alt{float:left;width:175px ;text-align:left;font-weight:bold;line-height:16px;margin-top:3px;padding-top:0}.left_head_add

  13. Genome sequence of the button mushroom Agaricus bisporus reveals mechanisms governing adaptation to a humic-rich ecological niche

    Treesearch

    Emmanuelle Morin; Annegret Kohler; Adam R. Baker; Marie Foulongne-Oriol; Vincent Lombard; Laszlo G. Nagy; Robin A. Ohm; Aleksandrina Patyshakuliyeva; Annick Brun; Andrea L. Aerts; Andrew M. Bailey; Christophe Billette; Pedro M. Coutinho; Greg Deakin; Harshavardhan Doddapaneni; Dimitrios Floudas; Jane Grimwood; Kristiina Hild& #233; n; Ursula K& #252; es; Kurt M. LaButti; Alla Lapidus; Erika A. Lindquist; Susan M. Lucas; Claude Murat; Robert W. Riley; Asaf A. Salamov; Jeremy Schmutz; Venkataramanan Subrananian; Han A.B. W& #246; sten; Jianping Xu; Daniel C. Eastwood; Gary D. Foster; Anton S.M. Sonnenberg; Daniel Cullen; Ronald P. de Vries; Taina Lundell; David S. Hibbett; Bernard Henrissat; Kerry S. Burton; Richard W. Kerrigan; Michael P. Challen; Igor V. Grigoriev; Francis Martin

    2012-01-01

    Agaricus bisporus is the model fungus for the adaptation, persistence,and growth in the humic-rich leaf-litter environment. Aside from its ecological role, A. bisporus has been an important component of the human diet for over 200 y and worldwide cultivation of the "button mushroom" forms a multibillion dollar...

  14. Don't wear that button out!

    NASA Astrophysics Data System (ADS)

    Jue, Brian J.; Bice, Michael D.

    2013-07-01

    As students explore the technological tools available to them for learning mathematics, some will eventually discover what happens when a function button is repeatedly pressed on a calculator. We explore several examples of this, presenting tabular and graphical results for the square root, natural logarithm and sine and cosine functions. Observed behaviour is proven and then discussed in the context of fixed points.

  15. A burr hole button to secure the electrode cable in depth electrode placement. Technical note.

    PubMed

    Kamiryo, T; Laws, E R

    1997-05-01

    A simple magnetic resonance imaging-compatible buttonlike device was devised to fix a depth electrode cable securely in the burr hole used for its insertion during surgery for depth electrode placement. The button is tightly fixed in the burr hole and it holds the cable without allowing protrusion or tension on the wound.

  16. Using Buttons to Better Manage Online Presence: How One Academic Institution Harnessed the Power of Flair

    ERIC Educational Resources Information Center

    Dority Baker, Marcia L.

    2013-01-01

    This article provides a case study of how the University of Nebraska College of Law and Schmid Law Library use "buttons" to manage Law College faculty members' and librarians' online presence. Since Google is the primary search engine used to find information, it is important that librarians and libraries assist Web site visitors in…

  17. --No Title--

    Science.gov Websites

    fixme{background-color:#ff0}.container-fluid{padding:0;margin:0}.hp{font-family:Roboto," }.hp-hero-text{position:absolute;text-shadow:1px 1px 1px rgba(150,150,150,1)}.hp-hero h2{color:#fff}.hp -hero button{color:#e3e3e3;font-size:10px;background:transparent;border:none}.hp-hero button:hover,.hp

  18. Management of foreign body ingestions in children: button batteries and magnets.

    PubMed

    Kodituwakku, Ronan; Palmer, Sarah; Paul, Siba Prosad

    2017-04-27

    Foreign body ingestion and foreign body aspiration commonly affect young children between 6 months and 6 years. A large number of these events remain unwitnessed and asymptomatic while the swallowed foreign body traverses the gastrointestinal tract and is passed in the stool. Recent literature has shown an increase in morbidity associated with button battery and (neomydium) magnet ingestions in children, particularly over the last decade. Early identification and management in a time critical manner is required in cases where button batteries get lodged in the oesophagus or multiple magnets are swallowed. Deaths, although rare, have been reported with these dangerous foreign body ingestions in children where diagnoses were delayed. Nurses through their direct contact with children in different clinical settings play a vital role in managing foreign body ingestions.

  19. Giant geode at the olecranon in the rheumatoid elbow--two case reports.

    PubMed

    Nakagawa, Natsuko; Abe, Shuji; Saegusa, Yasuhiro; Kimura, Hiroshi; Imura, Shigeaki; Nishibayashi, Yasuro; Yoshiya, Sinichi

    2004-08-01

    A single giant geode at the olecranon in a patient with rheumatoid arthritis (RA) is relatively rare, and may cause diagnostic difficulties or cause a spontaneous pathological fracture owing to weakness of the cortical bone associated with osteoporosis. We report two cases of patients presenting with single giant geodes at the olecranon. In one case we performed an open reduction and internal fixation with bone grafting for a pathological fracture due to the geode. In the other case we performed curettage of the geode with bone grafting to prevent a pathological fracture, and a synovectomy of the elbow. We suggest that the presence of a giant geode at the olecranon may necessitate surgical intervention to prevent the occurrence of a spontaneous pathological fracture.

  20. Pattern of Cortical Fracture following Corticotomy for Distraction Osteogenesis

    PubMed Central

    Luvan, M; Roshan, G; Saw, A

    2015-01-01

    Corticotomy is an essential procedure for deformity correction and there are many techniques described. However there is no proper classification of the fracture pattern resulting from corticotomies to enable any studies to be conducted. We performed a retrospective study of corticotomy fracture patterns in 44 patients (34 tibias and 10 femurs) performed for various indications. We identified four distinct fracture patterns, Type I through IV classification based on the fracture propagation following percutaneous corticotomy. Type I transverse fracture, Type II transverse fracture with a winglet, Type III presence of butterfly fragment and Type IV fracture propagation to a fixation point. No significant correlation was noted between the fracture pattern and the underlying pathology or region of corticotomy. PMID:28611907

  1. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?

    PubMed Central

    Zderic, I.; Grechenig, S.; Richards, R. G.; Schmitz, P.; Gueorguiev, B.

    2017-01-01

    Objectives Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. Materials and Methods A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm3 (standard deviation (sd) 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and gap angle at the fracture site were evaluated by means of optical movement tracking. The Wilcoxon signed-rank test was applied to identify significant differences between the groups Results Initial axial construct stiffness was not significantly different between the groups (p = 0.463). Interfragmentary displacement and gap angle at the fracture site were also not statistically significantly different between the groups throughout the evaluated cycles (p ⩾ 0.249). Similarly, cycles to failure were not statistically different between Group 1 (8438, sd 6968) and Group 2 (10 213, sd 10 334), p = 0.379. Failure mode in both groups was characterised by screw cutting through the cancellous bone. Conclusion From a biomechanical point of view, pubic ramus stabilisation with either one large or two small fragment screw osteosynthesis is comparable in osteoporotic bone. However, the two-screw fixation technique is less demanding as the smaller screws deflect at the cortical margins. Cite this article: Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P. Schmitz, B. Gueorguiev. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density? Bone Joint Res 2017;6:8–13. DOI: 10.1302/2046-3758.61.BJR-2016-0261. PMID:28057632

  2. Effect of dietary supplementation with white button mushrooms on host resistance to influenza infection and immune function in mice

    USDA-ARS?s Scientific Manuscript database

    Previously we showed that mice fed white button mushrooms (WBM) had enhanced immune functions known to help the body’s antiviral defense. In this study, we tested if WBM could afford protection against viral infection. Young (4-mo) and old (22-mo) C57BL/6 mice were fed a diet containing 0, 2 per cen...

  3. Type of Primary Nb₅Si₃ and Precipitation of Nbss in αNb₅Si₃ in a Nb-8.3Ti-21.1Si-5.4Mo-4W-0.7Hf (at.%) Near Eutectic Nb-Silicide-Based Alloy.

    PubMed

    McCaughey, Conor; Tsakiropoulos, Panos

    2018-06-07

    The Nb-silicide-based alloy of near eutectic composition (at.%) Nb-21.1Si-8.3Ti-5.4Mo-4W-0.7Hf (alloy CM1) was studied in the cast and heat-treated (1500 °C/100 h) conditions. The alloy was produced in the form of buttons and bars using three different methods, namely arc-melting, arc-melting and suction casting, and optical floating zone (OFZ) melting. In the former two cases the alloy solidified in water-cooled copper crucibles. Buttons and suction-cast bars of different size, respectively of 10 g and 600 g weight and 6 mm and 8 mm diameter, were produced. The OFZ bars were grown at three different growth rates of 12, 60 and 150 mm/h. It was confirmed that the type of Nb₅Si₃ formed in the cast microstructures depended on the solidification conditions. The primary phase in the alloy CM1 was the βNb₅Si₃. The transformation of βNb₅Si₃ to αNb₅Si₃ had occurred in the as cast large size button and the OFZ bars grown at the three different growth rates, and after the heat treatment of the small size button and the suction-cast bars of the alloy. This transformation was accompanied by subgrain formation in Nb₅Si₃ and the precipitation of Nb ss in the large size as cast button and only by the precipitation of Nb ss in the cast OFZ bars. Subgrains and precipitation of Nb ss in αNb₅Si₃ was observed in the small size button and suction-cast bars after the heat treatment. Subgrains formed in αNb₅Si₃ after the heat treatment of the OFZ bars. The partitioning of solutes and in particular of Mo and Ti was key to this phase transformation. Subgrain formation was not necessary for precipitation of Nb ss in αNb₅Si₃, but the partitioning of solutes was essential for this precipitation.

  4. Constitutive expression of the nifA gene activates associative nitrogen fixation of Enterobacter gergoviae 57-7, an opportunistic endophytic diazotroph.

    PubMed

    An, Q; Dong, Y; Wang, W; Li, Y; Li, J

    2007-09-01

    This study was undertaken to investigate whether a nitrogen-fixing bacterium Enterobacter gergoviae 57-7, which was isolated from surface-sterilized maize (Zea mays L.) roots, can colonize in roots and whether constitutive expression of the nifA gene encoding the transcriptional activator of nitrogenase genes can activate nif gene expression in planta. Maize seedlings grown in an agar medium were inoculated with Ent. gergoviae strains containing the green fluorescent protein reporter gene. Root colonization and expression of the dinitrogenase reductase gene (nifH) by Ent. gergoviae were observed by confocal laser scanning microscopy. gfp-tagged Ent. gergoviae was observed to colonize predominantly in cortical aerenchyma of primary and lateral roots and in stellar parenchyma cells and xylem vessels of primary roots. In planta nifH :: gfp expression was not detected but after a constitutively expressed nifA gene was introduced into Ent. gergoviae. Enterobacter gergoviae 57-7 is an opportunistic endophyte because it can live in soil and colonize in maize roots in the gnotobiotic agar culture. In agreement with previous (15)N-dilution evidence that Ent. gergoviae 57-7 did not fix N(2) in association with maize in pots whereas a derivative E7 containing a constitutively expressed nifA gene promoted plant growth partly through associative nitrogen fixation, constitutive expression of the nifA gene can activate bacterial nif gene expression in planta. This study and our previous studies suggest that manipulation of the promoter of the nifA gene in a nitrogen-fixing bacterium having a high colonization competence is a practical and promising approach to achieve a stable associative nitrogen fixation for cereals.

  5. Increased torsional stability by a novel femoral neck locking plate. The role of plate design and pin configuration in a synthetic bone block model.

    PubMed

    Brattgjerd, Jan Egil; Loferer, Martin; Niratisairak, Sanyalak; Steen, Harald; Strømsøe, Knut

    2018-06-01

    In undisplaced femoral neck fractures, internal fixation remains the main treatment, with mechanical failure as a frequent complication. As torsional stable fixation promotes femoral neck fracture healing, the Hansson Pinloc® System with a plate interlocking pins, was developed from the original hook pins. Since its effect on torsional stability is undocumented, the novel implant was compared with the original configurations. Forty-two proximal femur models custom made of two blocks of polyurethane foam were tested. The medial block simulated the cancellous head, while the lateral was laminated with a glass fiber filled epoxy sheet simulating trochanteric cortical bone. Two hollow metal cylinders with a circumferential ball bearing in between mimicked the neck, with a perpendicular fracture in the middle. Fractures were fixated by two or three independent pins or by five configurations involving the interlocking plate (two pins with an optional peg in a small plate, or three pins in a small, medium or large plate). Six torsional tests were performed on each configuration to calculate torsional stiffness, torque at failure and failure energy. The novel configurations improved parameters up to an average of 12.0 (stiffness), 19.3 (torque) and 19.9 (energy) times higher than the original two pins (P < 0.001). The plate, its size and its triangular configuration improved all parameters (P = 0.03), the plate being most effective, also preventing permanent failure (P < 0.001). The novel plate design with its pin configuration enhanced torsional stability. To reveal clinical relevance a clinical study is planned. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Cerclage handling for improved fracture treatment. A biomechanical study on the twisting procedure.

    PubMed

    Wähnert, D; Lenz, M; Schlegel, U; Perren, S; Windolf, M

    2011-01-01

    Twisting is clinically the most frequently applied method for tightening and maintaining cerclage fixation. The twisting procedure is controversially discussed. Several factors during twisting affect the mechanical behaviour of the cerclage. This in vitro study investigated the influence of different parameters of the twisting procedure on the fixation strength of the cerclage in an experimental setup with centripetal force application. Cortical half shells of the femoral shaft were mounted on a testing fixture. 1.0 mm, 1.25 mm and 1.5 mm stainless ste- el wire cerclages as well as a 1.0mm cable cerclage were applied to the bone. Pretension of the cerclage during the installation was measured during the locking procedure. Subsequently, cyclic testing was performed up to failure. Higher pretension could be achieved with increasing wire diameter. However, with larger wire diameter the drop of pre- tension due to the bending and cutting the twist also increased. The cable cerclage showed the highest pretension after locking. Cerclages twisted under traction revealed significantly higher initial cerclage tension. Plastically deformed twists offered higher cerclage pretension compared to twists which were deformed in the elastic region of the material. Cutting the wire within the twist caused the highest loss of cerclage tension (44% initial tension) whereas only 11 % was lost when cutting the wire ends separately. The bending direction of the twist significantly influenced the cerclage pretension. 45% pretension was lost in forward bending of the twist, 53% in perpendicular bending and 90% in backward bending. Several parameters affect the quality of a cerclage fixation. Adequate installation of cerclage wires could markedly improve the clinical outcome of cerclage.

  7. Machining of a bioactive nanocomposite orthopedic fixation device.

    PubMed

    Sparnell, Amie; Aniket; El-Ghannam, Ahmed

    2012-08-01

    Bioactive ceramics bond to bone and enhance bone formation. However, they have poor mechanical properties which restrict their machinability as well as their application as load bearing implants. The goal of this study was to machine bioactive fixation screws using a silica-calcium phosphate nanocomposite (SCPC50). The effect of compact pressure, holding time, and thermal treatment on the microstructure, machinability, and mechanical properties of SCPC50 cylinders were investigated. Samples prepared by powder metallurgy technique at compact pressure range of 100-300 MPa and treated at 900°C/1 h scored a poor machinability rating of (1/5) due to the significant formation of amorphous silicate phase at the grain boundaries. On the other hand, lowering of compact pressure and sintering temperature to 30 MPa/3 h and 700°C/2 h, respectively, minimized the formation of the amorphous phase and raised the machinability rating to (5/5). The modulus of elasticity and ultimate strength of machinable SCPC50 were 10.8 ± 2.0 GPa and 72.8 ± 22.8 MPa, respectively, which are comparable to the corresponding values for adult human cortical bone. qRT-PCR analyses showed that bone cells attached to SCPC50 significantly upregulated osteocalcin mRNA expression as compared to the cells on Ti-6Al-4V. Moreover, cells attached to SCPC50 produced mineralized bone-like tissue within 8 days. On the other hand, cells attached to Ti-6Al-4V failed to produce bone mineral under the same experimental conditions. Results of the study suggest that machinable SCPC50 has the potential to serve as an attractive new material for orthopedic fixation devices. Copyright © 2012 Wiley Periodicals, Inc.

  8. Dynamic locking screw improves fixation strength in osteoporotic bone: an in vitro study on an artificial bone model.

    PubMed

    Pohlemann, Tim; Gueorguiev, Boyko; Agarwal, Yash; Wahl, Dieter; Sprecher, Christoph; Schwieger, Karsten; Lenz, Mark

    2015-04-01

    The novel dynamic locking screw (DLS) was developed to improve bone healing with locked-plate osteosynthesis by equalising construct stiffness at both cortices. Due to a theoretical damping effect, this modulated stiffness could be beneficial for fracture fixation in osteoporotic bone. Therefore, the mechanical behaviour of the DLS at the screw-bone interface was investigated in an artificial osteoporotic bone model and compared with conventional locking screws (LHS). Osteoporotic surrogate bones were plated with either a DLS or a LHS construct consisting of two screws and cyclically axially loaded (8,500 cycles, amplitude 420 N, increase 2 mN/cycle). Construct stiffness, relative movement, axial screw migration, proximal (P) and distal (D) screw pullout force and loosening at the bone interface were determined and statistically evaluated. DLS constructs exhibited a higher screw pullout force of P 85 N [standard deviation (SD) 21] and D 93 N (SD 12) compared with LHS (P 62 N, SD 28, p = 0.1; D 57 N, SD 25, p < 0.01) and a significantly lower axial migration over cycles compared with LHS (p = 0.01). DLS constructs showed significantly lower axial construct stiffness (403 N/mm, SD 21, p < 0.01) and a significantly higher relative movement (1.1 mm, SD 0.05, p < 0.01) compared with LHS (529 N/mm, SD 27; 0.8 mm, SD 0.04). Based on the model data, the DLS principle might also improve in vivo plate fixation in osteoporotic bone, providing enhanced residual holding strength and reducing screw cutout. The influence of pin-sleeve abutment still needs to be investigated.

  9. Field comparison of three inhalable samplers (IOM, PGP-GSP 3.5 and Button) for welding fumes.

    PubMed

    Zugasti, Agurtzane; Montes, Natividad; Rojo, José M; Quintana, M José

    2012-02-01

    Inhalable sampler efficiency depends on the aerodynamic size of the airborne particles to be sampled and the wind speed. The aim of this study was to compare the behaviour of three personal inhalable samplers for welding fumes generated by Manual Metal Arc (MMA) and Metal Active Gas (MAG) processes. The selected samplers were the ones available in Spain when the study began: IOM, PGP-GSP 3.5 (GSP) and Button. Sampling was carried out in a welding training center that provided a homogeneous workplace environment. The static sampling assembly used allowed the placement of 12 samplers and 2 cascade impactors simultaneously. 183 samples were collected throughout 2009 and 2010. The range of welding fumes' mass concentrations was from 2 mg m(-3) to 5 mg m(-3). The pooled variation coefficients for the three inhalable samplers were less than or equal to 3.0%. Welding particle size distribution was characterized by a bimodal log-normal distribution, with MMADs of 0.7 μm and 8.2 μm. For these welding aerosols, the Button and the GSP samplers showed a similar performance (P = 0.598). The mean mass concentration ratio was 1.00 ± 0.01. The IOM sampler showed a different performance (P < 0.001). The mean mass concentration ratios were 0.90 ± 0.01 for Button/IOM and 0.92 ± 0.02 for GSP/IOM. This information is useful to consider the measurements accomplished by the IOM, GSP or Button samplers together, in order to assess the exposure at workplaces over time or to study exposure levels in a specific industrial activity, as welding operations.

  10. Anterior capsulotomy with an ultrashort-pulse laser.

    PubMed

    Tackman, Ramon Naranjo; Kuri, Jorge Villar; Nichamin, Louis D Skip; Edwards, Keith

    2011-05-01

    To assess the precision of laser anterior capsulotomy compared with that of manual continuous curvilinear capsulorhexis (CCC). Asociación Para Evitar La Ceguera en México IAP, Hospital Dr. Luis Sánchez Bulnes, Mexico City, Mexico. Nonrandomized single-center clinical trial. In patients presenting for cataract surgery, the LensAR Laser System was used to create a laser anterior capsulotomy of the surgeon's desired size. Capsule buttons were retrieved and measured and then compared with buttons retrieved from eyes having a manually torn CCC. Deviation from the intended diameter and the regularity of shape were assessed. When removing the capsule buttons at the start of surgery, the surgeon rated the ease of removal on a scale of 1 to 10 (1 = required manual capsulorhexis around the whole diameter; 10 = button free floating or required no manual detachment from remaining capsule during removal). The mean deviation from the intended diameter was 0.16 mm ± 0.17 (SD) for laser anterior capsulotomy and 0.42 ± 0.54 mm for CCC (P=.03). The mean absolute deviation from the intended diameter was 0.20 ± 0.12 mm and 0.49 ± 0.47 mm, respectively (P=.003). The mean of the average squared residuals was 0.01 ± 0.03 and 0.02 ± 0.04, respectively (P=.09). The median rating of the ease of removal was 9 (range 5 to 10). Laser anterior capsulotomy created a more precise capsule opening than CCC, and the buttons created by the laser procedure were easy to remove at the beginning of cataract surgery. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  11. Sport expertise: the role of precise timing of verbal-analytical engagement and the ability to detect visual cues.

    PubMed

    Taliep, Mogammad Sharhidd; John, Lester

    2014-01-01

    This study proposed that relative timing of high-alpha (10-12 Hz) left (T3) and right (T4) cortical temporal electroencephalographic (EEG) power levels would differentiate performance groups in a reactive sport such as cricket batting. The time course of EEG event-related alpha synchronisation (ERS) and desynchronisation was investigated in two groups (eight skilled and ten less skilled) of right-handed cricket batsmen whilst viewing projected video footage of a bowler delivering a randomised series of 24 deliveries repeated 10 times (total of 240 deliveries). Ball release from the bowler's hand was used as the corresponding reaction cue. Participants were instructed to press one of two buttons on a keypad to identify in-swingers or out-swingers. T3 ERS was significantly greater in skilled batsmen from approximately 1500 ms prior to ball release, but differences reduced close to ball release, reaching nonsignificance by 250 ms. There was no significant difference in T4 between the groups. This study uniquely highlights that the relative timing of the T3 high-alpha ERS state appears to differentiate batting skill groups in a reactive task.

  12. Perioperative alendronate, risedronate, calcitonin and indomethacin treatment alters femoral stem fixation and periprosthetic bone mineral density in ovariectomized rats.

    PubMed

    Cankaya, Deniz; Tabak, Yalcin; Ozturk, Akif Muhtar; Gunay, Muhammed Cuneyd

    2015-07-01

    Many factors affect implant stability and periprosthetic bone mineral density (BMD) following total joint arthroplasty. We asked whether perioperative alendronate, risedronate, calcitonin and indomethacine administration altered (1) femoral stem shear strength and periprosthetic bone mineral density BMD in ovariectomized rats and (2) whether there were differences in the effect of these drugs. Thirty overiectomized rats were divided into five groups and implanted with intramedullary mini-cortical screws in the femur. Four groups were treated with alendronate, risedronate, salmon calcitonin and indomethacin for 4 weeks preoperatively and 8 weeks postoperatively. Although alendronate and risedronate increased the periprosthetic BMD more than calcitonin, they did not alter implant fixation compared to calcitonin. Indomethacin significantly decreased the BMD around the stem and implant stability compared to all other groups. This study showed that perioperative treatment with bisphosphonates and calcitonin improved the BMD around the stems and implant stability. Although bisphosphonates increased the BMD more than calcitonin, there was no difference in implant stability. Indomethacin markedly decreased the periprosthetic BMD and implant stability. The main clinical significance of our study was the finding about the need to strictly avoid long-term use of high-dose nonsteroidal antiinflammatory drugs for patients who have major joint arthritis and a previous history of arthroplasty.

  13. Periprosthetic fractures of the humerus.

    PubMed

    McDonough, Edward B; Crosby, Lynn A

    2005-12-01

    Periprosthetic humeral fractures present a treatment challenge for the orthopedic surgeon. The overall incidence of fracture is between 0.5% and 3%, with the majority of fractures occurring intraoperatively and involving the humeral diaphysis. Excess torque produced during surgery is usually responsible for intraoperative fractures. Improper canal preparation or prosthetic placement may also increase the chance of sustaining a fracture. Postoperative fractures are most commonly caused by minor trauma, such as a fall. Poor bone quality, female sex, advanced age, and history of rheumatoid arthritis are the risk factors most commonly associated with periprosthetic fractures. All 4 systems used to describe periprosthetic humeral shaft fractures classify fracture patterns according to the anatomic relation of the fracture to the prosthetic stem. Treatment decisions should be made with respect to obtaining fracture stability, initiating early gleno-humeral motion, and restoring shoulder function. Intraoperative fractures and any postoperative fracture resulting in prosthetic instability should be treated with a long-stem prosthesis extending at least 2 to 3 cortical diameters past the fracture site with consideration for rigid plate fixation. Short oblique or transverse postoperative fractures should be managed with early stable fixation. There has been some support for conservative treatment of long oblique or spiral postoperative fractures. Postoperative diaphyseal fractures distal to the stem generally are well maintained with standard fracture management.

  14. State Recognition of Bone Drilling Based on Acoustic Emission in Pedicle Screw Operation.

    PubMed

    Guan, Fengqing; Sun, Yu; Qi, Xiaozhi; Hu, Ying; Yu, Gang; Zhang, Jianwei

    2018-05-09

    Pedicle drilling is an important step in pedicle screw fixation and the most significant challenge in this operation is how to determine a key point in the transition region between cancellous and inner cortical bone. The purpose of this paper is to find a method to achieve the recognition for the key point. After acquiring acoustic emission (AE) signals during the drilling process, this paper proposed a novel frequency distribution-based algorithm (FDB) to analyze the AE signals in the frequency domain after certain processes. Then we select a specific frequency domain of the signal for standard operations and choose a fitting function to fit the obtained sequence. Characters of the fitting function are extracted as outputs for identification of different bone layers. The results, which are obtained by detecting force signal and direct measurement, are given in the paper. Compared with the results above, the results obtained by AE signals are distinguishable for different bone layers and are more accurate and precise. The results of the algorithm are trained and identified by a neural network and the recognition rate reaches 84.2%. The proposed method is proved to be efficient and can be used for bone layer identification in pedicle screw fixation.

  15. Surgical plate fixation of multiple rib fractures: a case report.

    PubMed

    Mitev, Konstantin; Neziri, Dashurie; Stoicovski, Emil; Mitrev, Zan

    2018-05-29

    The healthcare system in developing countries is limited; particularly, medical specialties such as emergency and trauma medicine are underdeveloped. Consequently, trauma injuries sustained in traffic accidents result in chronic morbidity more often than similar cases in developed countries. Multiple rib fractures induce significant patient morbidity. Current international guidelines recommend a multidisciplinary, surgery-based treatment approach to achieve optimal clinical benefit. We admitted a 41-year-old Albanian man to our emergency department following a pedestrian-vehicle accident 5 days earlier. He presented with severe upper thoracic pain, chest deformity, dyspnea, tachycardia, subcutaneous emphysema, and hematoma. Chest radiography pointed to hypoventilated lung fields and a minor pleural effusion. Computed tomographic scans indicated displaced fractures of right lateral ribs 5 -11, hyperdensity regions from bone fragments, and pulmonary contusion. The treatment consisted of surgical fixation of ribs 7-10 using titanium reconstruction plates and cortical locking screws. The patient's clinical condition rapidly improved postoperatively. Follow-up at 6 weeks confirmed a full return to preoperative daily activities and a high quality of life. In this case report, we present a novel and promising development in the field of trauma medicine in the Republic of Macedonia. Trauma injuries can be treated via advanced multidisciplinary medical care according to international standards, allowing optimal health recovery.

  16. Neural mechanisms of eye contact when listening to another person talking.

    PubMed

    Jiang, Jing; Borowiak, Kamila; Tudge, Luke; Otto, Carolin; von Kriegstein, Katharina

    2017-02-01

    Eye contact occurs frequently and voluntarily during face-to-face verbal communication. However, the neural mechanisms underlying eye contact when it is accompanied by spoken language remain unexplored to date. Here we used a novel approach, fixation-based event-related functional magnetic resonance imaging (fMRI), to simulate the listener making eye contact with a speaker during verbal communication. Participants' eye movements and fMRI data were recorded simultaneously while they were freely viewing a pre-recorded speaker talking. The eye tracking data were then used to define events for the fMRI analyses. The results showed that eye contact in contrast to mouth fixation involved visual cortical areas (cuneus, calcarine sulcus), brain regions related to theory of mind/intentionality processing (temporoparietal junction, posterior superior temporal sulcus, medial prefrontal cortex) and the dorsolateral prefrontal cortex. In addition, increased effective connectivity was found between these regions for eye contact in contrast to mouth fixations. The results provide first evidence for neural mechanisms underlying eye contact when watching and listening to another person talking. The network we found might be well suited for processing the intentions of communication partners during eye contact in verbal communication. © The Author (2016). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  17. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

    PubMed

    Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-10-01

    The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

  18. Biomechanical evaluation of a novel Limb Prosthesis Osseointegrated Fixation System designed to combine the advantages of interference-fit and threaded solutions.

    PubMed

    Prochor, Piotr; Piszczatowski, Szczepan; Sajewicz, Eugeniusz

    2016-01-01

    The study was aimed at biomechanical evaluation of a novel Limb Prosthesis Osseointegrated Fixation System (LPOFS) designed to combine the advantages of interference-fit and threaded solutions. Three cases, the LPOFS (designed), the OPRA (threaded) and the ITAP (interference-fit) implants were studied. Von-Mises stresses in bone patterns and maximal values generated while axial loading on an implant placed in bone and the force reaction values in contact elements while extracting an implant were analysed. Primary and fully osteointegrated connections were considered. The results obtained for primary connection indicate more effective anchoring of the OPRA, however the LPOFS provides more appropriate stress distribution (lower stress-shielding, no overloading) in bone. In the case of fully osteointegrated connection the LPOFSs kept the most favourable stress distribution in cortical bone which is the most important long-term feature of the implant usage and bone remodelling. Moreover, in fully bound connection its anchoring elements resist extracting attempts more than the ITAP and the OPRA. The results obtained allow us to conclude that in the case of features under study the LPOFS is a more functional solution to direct skeletal attachment of limb prosthesis than the referential implants during short and long-term use.

  19. Comparison of visual receptive fields in the dorsolateral prefrontal cortex and ventral intraparietal area in macaques.

    PubMed

    Viswanathan, Pooja; Nieder, Andreas

    2017-12-01

    The concept of receptive field (RF) describes the responsiveness of neurons to sensory space. Neurons in the primate association cortices have long been known to be spatially selective but a detailed characterisation and direct comparison of RFs between frontal and parietal association cortices are missing. We sampled the RFs of a large number of neurons from two interconnected areas of the frontal and parietal lobes, the dorsolateral prefrontal cortex (dlPFC) and ventral intraparietal area (VIP), of rhesus monkeys by systematically presenting a moving bar during passive fixation. We found that more than half of neurons in both areas showed spatial selectivity. Single neurons in both areas could be assigned to five classes according to the spatial response patterns: few non-uniform RFs with multiple discrete response maxima could be dissociated from the vast majority of uniform RFs showing a single maximum; the latter were further classified into full-field and confined foveal, contralateral and ipsilateral RFs. Neurons in dlPFC showed a preference for the contralateral visual space and collectively encoded the contralateral visual hemi-field. In contrast, VIP neurons preferred central locations, predominantly covering the foveal visual space. Putative pyramidal cells with broad-spiking waveforms in PFC had smaller RFs than putative interneurons showing narrow-spiking waveforms, but distributed similarly across the visual field. In VIP, however, both putative pyramidal cells and interneurons had similar RFs at similar eccentricities. We provide a first, thorough characterisation of visual RFs in two reciprocally connected areas of a fronto-parietal cortical network. © 2017 Federation of European Neuroscience Societies and John Wiley & Sons Ltd.

  20. The neocortex of cetartiodactyls. II. Neuronal morphology of the visual and motor cortices in the giraffe (Giraffa camelopardalis).

    PubMed

    Jacobs, Bob; Harland, Tessa; Kennedy, Deborah; Schall, Matthew; Wicinski, Bridget; Butti, Camilla; Hof, Patrick R; Sherwood, Chet C; Manger, Paul R

    2015-09-01

    The present quantitative study extends our investigation of cetartiodactyls by exploring the neuronal morphology in the giraffe (Giraffa camelopardalis) neocortex. Here, we investigate giraffe primary visual and motor cortices from perfusion-fixed brains of three subadults stained with a modified rapid Golgi technique. Neurons (n = 244) were quantified on a computer-assisted microscopy system. Qualitatively, the giraffe neocortex contained an array of complex spiny neurons that included both "typical" pyramidal neuron morphology and "atypical" spiny neurons in terms of morphology and/or orientation. In general, the neocortex exhibited a vertical columnar organization of apical dendrites. Although there was no significant quantitative difference in dendritic complexity for pyramidal neurons between primary visual (n = 78) and motor cortices (n = 65), there was a significant difference in dendritic spine density (motor cortex > visual cortex). The morphology of aspiny neurons in giraffes appeared to be similar to that of other eutherian mammals. For cross-species comparison of neuron morphology, giraffe pyramidal neurons were compared to those quantified with the same methodology in African elephants and some cetaceans (e.g., bottlenose dolphin, minke whale, humpback whale). Across species, the giraffe (and cetaceans) exhibited less widely bifurcating apical dendrites compared to elephants. Quantitative dendritic measures revealed that the elephant and humpback whale had more extensive dendrites than giraffes, whereas the minke whale and bottlenose dolphin had less extensive dendritic arbors. Spine measures were highest in the giraffe, perhaps due to the high quality, perfusion fixation. The neuronal morphology in giraffe neocortex is thus generally consistent with what is known about other cetartiodactyls.

  1. Effect of screw torque level on cortical bone pullout strength.

    PubMed

    Cleek, Tammy M; Reynolds, Karen J; Hearn, Trevor C

    2007-02-01

    The objectives of this study were 2-fold: (1) to perform detailed analysis of cortical screw tightening stiffness during automated insertion, and (2) to determine the effect of 3 torque levels on the holding strength of the bone surrounding the screw threads as assessed by screw pullout. Ten pairs of ovine tibiae were used with 3 test sites spaced 20 mm apart centered along the shaft. One side of each pair was used for measuring ultimate failure torque (Tmax). These Tmax and bone-density values were used to predict Tmax at contralateral tibia sites. Screws were inserted and tightened to 50%, 70%, and 90% of predicted Tmax at the contralateral sites to encompass the average clinical level of torque (86% Tmax). Pullout tests were performed and maximum force values were normalized by cortical thickness. Torque to failure tests indicated tightening to 86% Tmax occurs after yield and leads to an average 51% loss in stiffness. Normalized pullout strength for screws tightened to 50% Tmax, 70% Tmax, and 90% Tmax were 2525 +/- 244, 2707 +/- 280, and 2344 +/- 346 N, respectively, with a significant difference between 70% Tmax and 90% Tmax groups (P < 0.05). Within the limitations of our study involving the testing of 1 type of screw purchase in ovine tibiae, results demonstrate that clinical levels of lag screw tightening (86% Tmax) are past the yield point of bone. Tightening to these high torque levels can cause damage leading to compromised holding strength. Further research is still required to establish the appropriate level of torque required for achieving optimal fracture fixation and healing.

  2. Posterior cortical atrophy: an investigation of scan paths generated during face matching tasks

    PubMed Central

    Meek, Benjamin P.; Locheed, Keri; Lawrence-Dewar, Jane M.; Shelton, Paul; Marotta, Jonathan J.

    2013-01-01

    When viewing a face, healthy individuals focus more on the area containing the eyes and upper nose in order to retrieve important featural and configural information. In contrast, individuals with face blindness (prosopagnosia) tend to direct fixations toward individual facial features—particularly the mouth. Presented here is an examination of face perception deficits in individuals with Posterior Cortical Atrophy (PCA). PCA is a rare progressive neurodegenerative disorder that is characterized by atrophy in occipito-parietal and occipito-temporal cortices. PCA primarily affects higher visual processing, while memory, reasoning, and insight remain relatively intact. A common symptom of PCA is a decreased effective field of vision caused by the inability to “see the whole picture.” Individuals with PCA and healthy control participants completed a same/different discrimination task in which images of faces were presented as cue-target pairs. Eye-tracking equipment and a novel computer-based perceptual task—the Viewing Window paradigm—were used to investigate scan patterns when faces were presented in open view or through a restricted-view, respectively. In contrast to previous prosopagnosia research, individuals with PCA each produced unique scan paths that focused on non-diagnostically useful locations. This focus on non-diagnostically useful locations was also present when using a restricted viewing aperture, suggesting that individuals with PCA have difficulty processing the face at either the featural or configural level. In fact, it appears that the decreased effective field of view in PCA patients is so severe that it results in an extreme dependence on local processing, such that a feature-based approach is not even possible. PMID:23825453

  3. Adhesion testing device

    NASA Technical Reports Server (NTRS)

    LaPeyronnie, Glenn M. (Inventor); Huff, Charles M. (Inventor)

    2010-01-01

    The present invention provides a testing apparatus and method for testing the adhesion of a coating to a surface. The invention also includes an improved testing button or dolly for use with the testing apparatus and a self aligning button hook or dolly interface on the testing apparatus. According to preferred forms, the apparatus and method of the present invention are simple, portable, battery operated rugged, and inexpensive to manufacture and use, are readily adaptable to a wide variety of uses, and provide effective and accurate testing results. The device includes a linear actuator driven by an electric motor coupled to the actuator through a gearbox and a rotatable shaft. The electronics for the device are contained in the head section of the device. At the contact end of the device, is positioned a self aligning button hook, attached below the load cell located on the actuator shaft.

  4. Connected cane: Tactile button input for controlling gestures of iOS voiceover embedded in a white cane.

    PubMed

    Batterman, Jared M; Martin, Vincent F; Yeung, Derek; Walker, Bruce N

    2018-01-01

    Accessibility of assistive consumer devices is an emerging research area with potential to benefit both users with and without visual impairments. In this article, we discuss the research and evaluation of using a tactile button interface to control an iOS device's native VoiceOver Gesture navigations (Apple Accessibility, 2014). This research effort identified potential safety and accessibility issues for users trying to interact and control their touchscreen mobile iOS devices while traveling independently. Furthermore, this article discusses the participatory design process in creating a solution that aims to solve issues in utilizing a tactile button interface in a novel device. The overall goal of this study is to enable visually impaired white cane users to access their mobile iOS device's capabilities navigation aids more safely and efficiently on the go.

  5. Neonatal treatment with monosodium glutamate lastingly facilitates spreading depression in the rat cortex.

    PubMed

    Lima, Cássia Borges; Soares, Geórgia de Sousa Ferreira; Vitor, Suênia Marcele; Castellano, Bernardo; Andrade da Costa, Belmira Lara da Silveira; Guedes, Rubem Carlos Araújo

    2013-09-17

    Monosodium glutamate (MSG) is a neuroexcitatory amino acid used in human food to enhance flavor. MSG can affect the morphological and electrophysiological organization of the brain. This effect is more severe during brain development. Here, we investigated the electrophysiological and morphological effects of MSG in the developing rat brain by characterizing changes in the excitability-related phenomenon of cortical spreading depression (CSD) and microglial reaction. From postnatal days 1-14, Wistar rat pups received 2 or 4 g/kg MSG (groups MSG-2 and MSG-4, respectively; n=9 in each group), saline (n=10) or no treatment (naïve group; n=5) every other day. At 45-60 days, CSD was recorded on two cortical points for 4h. The CSD parameters velocity, and amplitude and duration of the negative potential change were calculated. Fixative-perfused brain sections were immunolabeled with anti-IBA-1 antibodies to identify and quantify cortical microglia. MSG-4 rats presented significantly higher velocities (4.59 ± 0.34 mm/min) than the controls (saline, 3.84 ± 0.20mm/min; naïve, 3.71 ± 0.8mm/min) and MSG-2 group (3.75 ± 0.10mm/min). The amplitude (8.8 ± 2.2 to 11.2 ± 1.9 mV) and duration (58.2 ± 7.1 to 73.6 ± 6.0s) of the negative slow potential shift was similar in all groups. MSG-treatment dose-dependently increased the microglial immunolabeling. The results demonstrate a novel, dose-dependent action of MSG in the developing brain, characterized by acceleration of CSD and significant microglial reaction in the cerebral cortex. The CSD effect indicates that MSG can influence cortical excitability, during brain development, as evaluated by CSD acceleration. Data suggest caution when consuming MSG, especially in developing organisms. © 2013.

  6. Is the Go/No-Go Lexical Decision Task Preferable to the Yes/No Task with Developing Readers?

    ERIC Educational Resources Information Center

    Moret-Tatay, Carmen; Perea, Manuel

    2011-01-01

    The lexical decision task is probably the most common laboratory visual word identification task together with the naming task. In the usual setup, participants need to press the "yes" button when the stimulus is a word and the "no" button when the stimulus is not a word. A number of studies have employed this task with developing readers;…

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCracken, Brewster

    Through funding from the Department of Energy’s Electricity Delivery and Reliability Office, Pecan Street Inc., in partnership with Austin Energy and Oncor, developed and tested third- party data access platforms and services for Green Button offerings and for other home energy use data providers. As more utilities seek to offer Green Button-compliant data to their customers, the question continually arises of how this data can be used to help customers better manage their energy use.

  8. Hot-Button Issues for Teachers: What Every Educator Needs to Know About Leadership, Testing, Textbooks, Vouchers, and More

    ERIC Educational Resources Information Center

    Vairo, Philip D.; Marcus, Sheldon; Weiner, Max

    2007-01-01

    One of the tragedies of American education is that so many teachers do not understand or are unaware of educational issues and how they impact on their profession. There is a gap between teacher perceptions and reality and this book is a first step in closing that gap. Hot-Button Issues for Teachers is a timely, comprehensive book that addresses…

  9. Supplemental Archeological Investigations of Lower Bayou Teche, St. Mary Parish, Louisiana

    DTIC Science & Technology

    1991-08-01

    Ruler end (brass)1 ____ Buckle 1__________ Brass and inlaid shell button 1____ Chain 2 71 Cosmetic cap - gild brass inlaid with shell 1I____ 185...Molded stemnware fragment ____ _____ _____ Unidentified ______ ______1 Perfume/ Cosmetic Bottle Fragment Milk glass 2 Melted Glass Aqua1 Unidentified...major portion of the recovery (n = 122). Other metal artifacts included 2 safety pins, 1 cosmetic cap made of gilt brass inlaid with shell, 3 buttons

  10. Allelopathic effects of the aqueous extract of the leaf and seed of Leucaena leucocephala on three selected weed species

    NASA Astrophysics Data System (ADS)

    Ishak, Muhamad Safwan; Sahid, Ismail

    2014-09-01

    A laboratory experiment was conducted to study the allelopathic effects of the aqueous extract of the leaf and seed of Leucaena leucocephala. The aqueous extracts were individually tested on three selected weed species, namely goatweed (Ageratum conyzoides), coat buttons (Tridax procumbens) and lilac tasselflower (Emilia sonchifolia). The allelopathic effects of the leaf and seed extracts on germination, shoot length, root length and fresh weight of each of the selected weed species were determined. Germination of goatweed, coat buttons and lilac tasselflower were inhibited by the aqueous extracts of both the leaf and seed of L. leucocephala and was concentration dependent. Different concentrations of the aqueous extracts showed various germination patterns on the selected weeds species. Seedling length and fresh weight of goatweed, coat buttons and lilac tasselflower were reduced in response to respective increasing concentrations of the seed extracts. Maximum inhibition by the aqueous seed extract was observed more on the root rather than the shoot growth. The aqueous seed extract at T3 concentration reduced root length of goatweed, coat buttons and lilac tasselflower by 95%, 86% and 91% (of the control) respectively. The aqueous seed extract showed greater inhibitory effects than that of the aqueous leaf extract.

  11. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  12. Distinct dynamical patterns that distinguish willed and forced actions.

    PubMed

    Garcia Dominguez, Luis; Kostelecki, Wojciech; Wennberg, Richard; Perez Velazquez, Jose L

    2011-03-01

    The neural pathways for generating willed actions have been increasingly investigated since the famous pioneering work by Benjamin Libet on the nature of free will. To better understand what differentiates the brain states underlying willed and forced behaviours, we performed a study of chosen and forced actions over a binary choice scenario. Magnetoencephalography recordings were obtained from six subjects during a simple task in which the subject presses a button with the left or right finger in response to a cue that either (1) specifies the finger with which the button should be pressed or (2) instructs the subject to press a button with a finger of their own choosing. Three independent analyses were performed to investigate the dynamical patterns of neural activity supporting willed and forced behaviours during the preparatory period preceding a button press. Each analysis offered similar findings in the temporal and spatial domains and in particular, a high accuracy in the classification of single trials was obtained around 200 ms after cue presentation with an overall average of 82%. During this period, the majority of the discriminatory power comes from differential neural processes observed bilaterally in the parietal lobes, as well as some differences in occipital and temporal lobes, suggesting a contribution of these regions to willed and forced behaviours.

  13. The Free-Hand Technique for S2-Alar-Iliac Screw Placement: A Safe and Effective Method for Sacropelvic Fixation in Adult Spinal Deformity.

    PubMed

    Shillingford, Jamal N; Laratta, Joseph L; Tan, Lee A; Sarpong, Nana O; Lin, James D; Fischer, Charla R; Lehman, Ronald A; Kim, Yongjung J; Lenke, Lawrence G

    2018-02-21

    Spinopelvic fixation is an integral part of achieving solid fusion across the lumbosacral junction, especially in deformity procedures requiring substantial correction or long-segment constructs. Traditional S2-alar-iliac (S2AI) screw-placement techniques utilize fluoroscopy, increasing operative time and radiation exposure to the patient and surgeon. We describe a novel free-hand technique for S2AI screw placement in patients with adult spinal deformity. We reviewed the records of 45 consecutive patients who underwent spinopelvic fixation performed with use of S2AI screws by the senior surgeon and various fellows or residents over a 12-month period (2015 to 2016). In each case, the S2AI screws were placed utilizing a free-hand technique without fluoroscopic or image guidance. Screw position and accuracy were assessed by intraoperative O-arm imaging and analyzed using 3-dimensional interactive manipulation of computed tomography images. A total of 100 screws were placed, 51 by the senior surgeon and 49 by trainees. The mean patient age was 57.4 ± 12.7 years at the time of surgery; 37 (82.2%) of the patients were female. Preoperative diagnoses included adult idiopathic scoliosis (n = 19), adult degenerative scoliosis (n = 15), flatback syndrome (n = 2), fixed sagittal imbalance (n = 6), and distal junctional kyphosis (n = 3). Five (5%) of the screws were placed with moderate to severe cortical breaches, all of which perforated the pelvis posteriorly, with no clinically notable neurovascular or visceral complications. The breach rate did not differ significantly between the senior surgeon and trainees. The free-hand technique for S2AI screw placement, when performed in a standardized manner, was demonstrated to be safe and reliable in constructs requiring spinopelvic fixation. The accuracy of screw placement relies on visible and palpable anatomic landmarks that obviate the need for intraoperative fluoroscopy or image guidance, potentially reducing operative time and radiation exposure. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  14. Evaluation and management of injuries of the tibiofibular syndesmosis.

    PubMed

    Magan, Ahmed; Golano, Pau; Maffulli, Nicola; Khanduja, Vikas

    2014-09-01

    Injury to the tibiofibular syndesmosis often arises from external rotation force acting on the foot leading to eversion of the talus within the ankle mortise and increased dorsiflexion or plantar flexion. Such injuries can present in the absence of a fracture. Therefore, diagnosis of these injuries can be challenging, and often stress radiographs are helpful. Magnetic resonance imaging scans can be a useful adjunct in doubtful cases. The management of syndesmotic injuries remains controversial, and there is no consensus on how to optimally fix syndesmosis. This article reviews the mechanism of injury, clinical features and investigations performed for syndesmotic injuries and brings the reader up-to-date with the current evidence in terms of the controversies surrounding the management of these injuries. Embase, Pubmed Medline, Cochrane Library, Elsevier and Google Scholar (January 1950-2014). The management of syndesmotic injuries remains controversial, and there is no consensus on: (i) which ankle fractures require syndesmotic fixation, (ii) the number or the size and the type of screws that should be used for fixation, (iii) how many cortices to engage for fixation, (iv) the level of screw placement above the ankle plafond, (v) the duration for which the screw needs to remain in situ to allow the tibiofibular syndesmosis to heal and (vi) when should patients weight bear. (i) A high proportion of syndesmotic fixations demonstrates malreduction of the syndesmosis, (ii) no need to remove screws routinely, (iii) two screws appear to better one alone and (iv) if syndesmosis injury is not detected or not treated long term, it leads to pain and arthritis. (i) How to assess the adequacy of syndesmotic reduction using imaging in the peri-operative period, (ii) the use of bio-absorbable materials and Tightrope and (iii) evidence is emerging not to remove syndesmotic screws unless symptomatic. (i) A bio-absorbable material that can be used to fix the syndesmosis and allow early weight bearing, and (ii) there is a need for developing a surgical technique for adequately reducing the syndesmosis without the exposure to radiation. © The Author 2014. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  15. Aberrant development of post-movement beta rebound in adolescents and young adults with fetal alcohol spectrum disorders

    PubMed Central

    Vakhtin, Andrei A.; Kodituwakku, Piyadasa W.; Garcia, Christopher M.; Tesche, Claudia D.

    2015-01-01

    Dependent on maternal (e.g. genetic, age) and exposure (frequency, quantity, and timing) variables, the effects of prenatal alcohol exposure on the developing fetus are known to vary widely, producing a broad range of morphological anomalies and neurocognitive deficits in offspring, referred to as fetal alcohol spectrum disorders (FASD). Maternal drinking during pregnancy remains a leading risk factor for the development of intellectual disabilities in the US. While few functional findings exist today that shed light on the mechanisms responsible for the observed impairments in individuals with FASD, animal models consistently report deleterious effects of early alcohol exposure on GABA-ergic inhibitory pathways. The post-motor beta rebound (PMBR), a transient increase of 15–30 Hz beta power in the motor cortex that follows the termination of movement, has been implicated as a neural signature of GABA-ergic inhibitory activity. Further, PMBR has been shown to be a reliable predictor of age in adolescents. The present study sought to investigate any differences in the development of PMBR between FASD and control groups. Beta event-related de-synchronization (ERD) and movement-related gamma synchronization (MRGS), although not clearly linked to brain maturation, were also examined. Twenty-two participants with FASD and 22 age and sex-matched controls (12–22 years old) underwent magnetoencephalography scans while performing an auditory oddball task, which required a button press in response to select target stimuli. The data surrounding the button presses were localized to the participants' motor cortices, and the time courses from the locations of the maximally evoked PMBR were subjected to wavelet analyses. The subsequent analysis of PMBR, ERD, and MRGS revealed a significant interaction between group and age in their effects on PMBR. While age had a significant effect on PMBR in the controls, no simple effects of age were detected in the FASD group. The FASD group additionally displayed decreased overall ERD levels. No group or age effects on MRGS were detected. The described findings provide further evidence for broad impairments in inhibitory processes in adolescents with FASD, possibly related to aberrant development of GABA-ergic pathways. PMID:26594621

  16. A Study of Selected Problems in Armor Operations

    DTIC Science & Technology

    1978-11-01

    of external environmental cond~tions on the internal environment of a buttoned-up tank. Another effort was a study of problems in escape and...Test site configuration: Study II ......... ... IV-16 FIG. IVT4. Mean time to lay on target .... ........ .... IV-20 TABLES Chapter III Table III-I...L., and Ton, W. H. Study of the Psychological (and Associated Physiological) Effjcts on a Tank Crew Resulting From Being Buttoned Up, ARI Research

  17. BPM Breakdown Potential in the PEP-II B-factory Storage Ring Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weathersby, Stephen; Novokhatski, Alexander; /SLAC

    2010-02-10

    High current B-Factory BPM designs incorporate a button type electrode which introduces a small gap between the button and the beam chamber. For achievable currents and bunch lengths, simulations indicate that electric potentials can be induced in this gap which are comparable to the breakdown voltage. This study characterizes beam induced voltages in the existing PEP-II storage ring collider BPM as a function of bunch length and beam current.

  18. Consortium Requirements Engineering Guidebook

    DTIC Science & Technology

    1993-12-01

    re- quirements among developers or contractors, acquisition managers, and users. A CoRE specification serves as both the test -to and design-to...that are used for the following purposes: (1) the button labeled SELF TEST allows the operator to check the FLMS’s output hardware while the system is...shut down; and (2) the button labeled RESET allows the system to be brought back into normal operation following a shutdown or testing as long as the

  19. An ergonomics study of thumb movements on smartphone touch screen.

    PubMed

    Xiong, Jinghong; Muraki, Satoshi

    2014-01-01

    This study investigated the relationships between thumb muscle activity and thumb operating tasks on a smartphone touch screen with one-hand posture. Six muscles in the right thumb and forearm were targeted in this study, namely adductor pollicis, flexor pollicis brevis, abductor pollicis brevis (APB), abductor pollicis longus, first dorsal interosseous (FDI) and extensor digitorum. The performance measures showed that the thumb developed fatigue rapidly when tapping on smaller buttons (diameter: 9 mm compared with 3 mm), and moved more slowly in flexion-extension than in adduction-abduction orientation. Meanwhile, the electromyography and perceived exertion values of FDI significantly increased in small button and flexion-extension tasks, while those of APB were greater in the adduction-abduction task. This study reveals that muscle effort among thumb muscles on a touch screen smartphone varies according to the task, and suggests that the use of small touch buttons should be minimised for better thumb performance.

  20. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff R.; Biscardi, C.; Cerniglia, P.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less

  1. Archeological Survey and Testing in the Holy Cross Historic District, New Orleans, Louisiana. Volume 2

    DTIC Science & Technology

    1992-02-01

    467 Table 4 Personal Items from Shovel Tests, 160R130. SURF SURF SURF N15 N5 NO NO $5 S5 1 2 3 W20 El5 E20 W10 E20 EO Bone button, Type B-5 Ceramic...Table 4 . Personal Items from Shovel Tests, 160R130. S15 S20 S20 S25 S25 S30 S30 S30 S32.5 E5 E35 E20 E50 E25 E50 E35 E20 E35 Bone button, Type B-5...1 1 1 7 1 471 Table 4 Personal Items from Shovel Tests, 160R130. S30 S34 S35 S45 S50 TOTAL El0 E35 E30 E30 E55 Bone button, Type B-5 1 1 Ceramic

  2. Paper-based piezoelectric touch pads with hydrothermally grown zinc oxide nanowires.

    PubMed

    Li, Xiao; Wang, Yu-Hsuan; Zhao, Chen; Liu, Xinyu

    2014-12-24

    This paper describes a new type of paper-based piezoelectric touch pad integrating zinc oxide nanowires (ZnO NWs), which can serve as user interfaces in paper-based electronics. The sensing functionality of these touch pads is enabled by the piezoelectric property of ZnO NWs grown on paper using a simple, cost-efficient hydrothermal method. A piece of ZnO-NW paper with two screen-printed silver electrodes forms a touch button, and touch-induced electric charges from the button are converted into a voltage output using a charge amplifier circuit. A touch pad consisting of an array of buttons can be readily integrated into paper-based electronic devices, allowing user input of information for various purposes such as programming, identification checking, and gaming. This novel design features ease of fabrication, low cost, ultrathin structure, and good compatibility with techniques in printed electronics, and further enriches the available technologies of paper-based electronics.

  3. Postural Control and Emotion in Children with Autism Spectrum Disorders

    PubMed Central

    Gouleme, Nathalie; Scheid, Isabelle; Peyre, Hugo; Seassau, Magali; Maruani, Anna; Clarke, Julia; Delorme, Richard; Bucci, Maria Pia

    2017-01-01

    Abstract Autism Spectrum Disorders subjects (ASD) are well known to have deficits in social interaction. We recorded simultaneously eye movements and postural sway during exploration of emotional faces in children with ASD and typically developing children (TD). We analyzed several postural and ocular parameters. The results showed that all postural parameters were significantly greater in children with ASD; ASD made significantly fewer saccades and had shorter fixation time than TD, particularly in the eyes, and especially for unpleasant emotions. These results suggest that poor postural control of ASD and their impaired visual strategies could be due to a lack of interest in social cognition, causing a delay in the development of the cortical areas, and thus could have an effect on their postural control. PMID:29177103

  4. An Active System for Visually-Guided Reaching in 3D across Binocular Fixations

    PubMed Central

    2014-01-01

    Based on the importance of relative disparity between objects for accurate hand-eye coordination, this paper presents a biological approach inspired by the cortical neural architecture. So, the motor information is coded in egocentric coordinates obtained from the allocentric representation of the space (in terms of disparity) generated from the egocentric representation of the visual information (image coordinates). In that way, the different aspects of the visuomotor coordination are integrated: an active vision system, composed of two vergent cameras; a module for the 2D binocular disparity estimation based on a local estimation of phase differences performed through a bank of Gabor filters; and a robotic actuator to perform the corresponding tasks (visually-guided reaching). The approach's performance is evaluated through experiments on both simulated and real data. PMID:24672295

  5. Analysis of temperature in conventional and ultrasonically-assisted drilling of cortical bone with infrared thermography.

    PubMed

    Alam, K; Silberschmidt, Vadim V

    2014-01-01

    Bone drilling is widely used in orthopaedics, dental and neurosurgeries for repair and fixation purposes. One of the major concerns in drilling of bone is thermal necrosis that may seriously affect healing at interfaces with fixtures and implants. Ultrasonically-assisted drilling (UAD) is recently introduced as alternative to conventional drilling (CD) to minimize invasiveness of the procedure. This paper studies temperature rise in bovine cortical bone drilled with CD and UAD techniques and their comparison using infrared thermography. A parametric investigation was carried out to evaluate effects of drilling conditions (drilling speed and feed rate) and parameters of ultrasonic vibration (frequency and amplitude) on the temperature elevation in bone. Higher levels of the drilling speed and feed rate were found responsible for generating temperatures above a thermal threshold level in both types of drilling. UAD with frequency below 20 kHz resulted in lower temperature compared to CD with the same drilling parameters. The temperatures generated in cases with vibration frequency exceeding 20 kHz were significantly higher than those in CD for the range of drilling speeds and feed rates. The amplitude of vibration was found to have no significant effect on bone temperature. UAD may be investigated further to explore its benefits over the existing CD techniques.

  6. Exploring thermal anisotropy of cortical bone using temperature measurements in drilling.

    PubMed

    Alam, Khurshid

    2016-05-12

    Bone drilling is widely used in orthopaedics for fracture treatment, reconstructive surgery and bone biopsy. Heat generation in bone drilling can cause rise in bone temperature resulting in prolonged healing time or loosening of fixation. The purpose of this study was to investigate thermal anisotropy of bone by measuring the level of temperature in bone drilling with and without cooling conditions in two anatomical directions. Drilling tests were performed on bovine cortical bone. A total of fifteen specimens were used to obtain data for statistical analysis. Temperature near the cutting zone was measured in two anatomical directions. i.e. along the longitudinal and circumferential direction. Temperature distribution was also found in the two prescribed directions. Analysis of variance (ANOVA) was used to identify significant drilling parameter affecting bone temperature. Drilling speed, feed rate and drill size were found influential parameters affecting bone temperature. Higher drilling speed, feed rate, and large drill size were found to cause elevated temperature in bone. Much lower temperature was measured in bone when cooling fluid was supplied to the drilling region. Experimental results revealed lower temperatures in the circumferential direction compared to the longitudinal direction. Thermal anisotropy for heat transport was found in the bone. This study recommends lower drilling speed and feed rate and cooling for controlling rise in bone temperature.

  7. The organization of orientation selectivity throughout macaque visual cortex.

    PubMed

    Vanduffel, Wim; Tootell, Roger B H; Schoups, Aniek A; Orban, Guy A

    2002-06-01

    A double-label deoxyglucose technique was used to study orientation columns throughout visual cortex in awake behaving macaques. Four macaques were trained to fixate while contrastreversing, stationary gratings or one-dimensional noise of a single orientation or an orthogonal orientation were presented, during uptake of [14C]deoxyglucose ([14C]DG) or [3H]DG, respectively. The two orthogonal stimulus orientations produced DG-labeled columns that were maximally separated in the two isotope maps (inter-digitated) in four areas: V1, V2, V3 and VP. The topographic change from interdigitated to overlapping columns occurred abruptly rather than gradually, at corresponding cortical area borders (e.g. VP and V4v, respectively). In addition, the data suggest that orientation column topography systematically changes with retinotopic eccentricity. In V1, the orientation columns systematically avoided the cytochrome oxidase blobs in the parafoveal representation, but converged closer to the blobs in the foveal representation. A control experiment indicated that this was unlikely to reflect eccentricity-dependent differences in cortical spatial frequency sensitivity. A similar eccentricity-dependent change in the topography of orientation columns occurred in V2. In parafoveal but not foveal visual field representations of V2, the orientation columns were centered on the thick cytochrome oxidase stripes, extended into the adjacent interstripe region, but were virtually absent in the thin stripes.

  8. Is empathy necessary to comprehend the emotional faces? The empathic effect on attentional mechanisms (eye movements), cortical correlates (N200 event-related potentials) and facial behaviour (electromyography) in face processing.

    PubMed

    Balconi, Michela; Canavesio, Ylenia

    2016-01-01

    The present research explored the effect of social empathy on processing emotional facial expressions. Previous evidence suggested a close relationship between emotional empathy and both the ability to detect facial emotions and the attentional mechanisms involved. A multi-measure approach was adopted: we investigated the association between trait empathy (Balanced Emotional Empathy Scale) and individuals' performance (response times; RTs), attentional mechanisms (eye movements; number and duration of fixations), correlates of cortical activation (event-related potential (ERP) N200 component), and facial responsiveness (facial zygomatic and corrugator activity). Trait empathy was found to affect face detection performance (reduced RTs), attentional processes (more scanning eye movements in specific areas of interest), ERP salience effect (increased N200 amplitude), and electromyographic activity (more facial responses). A second important result was the demonstration of strong, direct correlations among these measures. We suggest that empathy may function as a social facilitator of the processes underlying the detection of facial emotion, and a general "facial response effect" is proposed to explain these results. We assumed that empathy influences cognitive and the facial responsiveness, such that empathic individuals are more skilful in processing facial emotion.

  9. Immunodetection and intracellular localization of caldesmon-like proteins in Amoeba proteus.

    PubMed

    Gagola, M; Kłopocka, W; Greebecki, A; Makuch, R

    2003-09-01

    Caldesmon immunoanalogues were detected in Amoeba proteus cell homogenates by the Western blot technique. Three immunoreactive bands were recognized by polyclonal antibodies against the whole molecule of chicken gizzard caldesmon as well as by a monoclonal antibody against its C-terminal domain: one major and two minor bands corresponding to proteins with apparent molecular masses of 150, 69, and 60 kDa. The presence of caldesmon-like protein(s) in amoebae was revealed as well in single cells after their fixation, staining with the same antibodies, and recording their total fluorescence in a confocal laser scanning microscope. Proteins recognized by the antibodies bind to filamentous actin. This was established by a cosedimentation assay in cell homogenates and by colocalization of the caldesmon-related immunofluorescence with the fluorescence of filamentous actin stained with rhodamine-labelled phalloidin, demonstrated in optical sections of single cells in a confocal microscope. Caldesmon is colocalized with filamentous actin in the withdrawn cell regions where the cortical actomyosin network contracts and actin is depolymerized, in the frontal zone where actin is polymerized again and the cortical cytoskeleton is reconstructed, inside the nucleus and in the perinuclear cytoskeleton, and probably at the cell-to-substratum adhesion sites. The regulatory role of caldesmon in these functionally different regions of locomoting amoebae is discussed.

  10. Collaborative Systems and Multi-user Interfaces: Computer-based Tools for Cooperative Problem Solving

    DTIC Science & Technology

    1986-10-31

    Reference Card Given to Participants) Cognoter Reference Select = LeftButton Menu = MiddleButton TitleBar menu for tool operations Item menu for item...collaborative tools and their uses, the Colab system and the Cognoter presentation tool were implemented and used for both real and posed idea organization...tasks. To test the system design and its effect on structured problem-solving, many early Colab/ Cognoter meetings were monitored and a series of

  11. Evaluation of tooth-click triggering and speech recognition in assistive technology for computer access.

    PubMed

    Simpson, Tyler; Gauthier, Michel; Prochazka, Arthur

    2010-02-01

    Computer access can play an important role in employment and leisure activities following spinal cord injury. The authors' prior work has shown that a tooth-click detecting device, when paired with an optical head mouse, may be used by people with tetraplegia for controlling cursor movement and mouse button clicks. To compare the efficacy of tooth clicks to speech recognition and that of an optical head mouse to a gyrometer head mouse for cursor and mouse button control of a computer. Six able-bodied and 3 tetraplegic subjects used the devices listed above to produce cursor movements and mouse clicks in response to a series of prompts displayed on a computer. The time taken to move to and click on each target was recorded. The use of tooth clicks in combination with either an optical head mouse or a gyrometer head mouse can provide hands-free cursor movement and mouse button control at a speed of up to 22% of that of a standard mouse. Tooth clicks were significantly faster at generating mouse button clicks than speech recognition when paired with either type of head mouse device. Tooth-click detection performed better than speech recognition when paired with both the optical head mouse and the gyrometer head mouse. Such a system may improve computer access for people with tetraplegia.

  12. Inclusion Behavior During the Electron Beam Button Melting Test

    NASA Astrophysics Data System (ADS)

    Bellot, J. P.; Defay, B.; Jourdan, J.; Chapelle, P.; Jardy, A.

    2012-10-01

    The high mechanical performance of alloys developed for the manufacture of turbine disks depend upon the size and the number density of the inclusions. The electron beam button method has been practiced since the 1980s as a technique to quantify the cleanliness of the superalloys as well as to identify the nature and the size of the inclusions. The technique involves melting the sample into a hemispherical water-cooled crucible and the low density inclusions (mainly oxides) are concentrated by a combination of Marangoni and buoyancy forces into an area at the top surface of the button referred to as the raft. We have experimentally studied the behavior of oxide inclusions in special steels using both high definition video and infrared cameras. We have observed the inversion of the Marangoni effect due to the presence of sulfur, which leads to a positive temperature coefficient of the surface tension. A mathematical modeling has been carried out to simulate the turbulent fluid flow associated with the temperature field in the metallic pool of the button. The surface temperature profile has been successfully compared with the measured data. A post-processor numerical tool calculates the inclusion trajectories taking into account the turbulent fluctuation velocity by a stochastic approach. Hence, the behavior of a population of inclusions has been statistically studied, and the dependence of the capture efficiency on the inclusion size has been analyzed.

  13. Fate of the syndesmotic screw--Search for a prudent solution.

    PubMed

    Kaftandziev, Igor; Spasov, Marko; Trpeski, Simon; Zafirova-Ivanovska, Beti; Bakota, Bore

    2015-11-01

    Ankle fractures are common injuries. Since the recognition of the importance of syndesmotic injury in ankle fractures, much of the scientific work has been focused on concomitant syndesmotic injury. Despite the invention of novel devices for restoration and maintenance of the congruent syndesmosis following syndesmotic injury, the metallic syndesmotic screw is still considered to be the "gold standard". The aim of this study was to compare the clinical results in patients who retained the syndesmosis screw with those in whom the screw was removed following open reduction and internal fixation of the malleolar fracture associated with syndesmosis disruption. This was a retrospective study of 82 patients. Minimum follow-up was 12 months. Clinical evaluation included American Orthopaedic Foot and Ankle Society (AOFAS) score and Visual Analogue Scale (VAS) for patient general satisfaction. The condition of the screw (removed, intact or broken), presence of radiolucency around the syndesmotic screw and the tibiofibular clear space were recorded using final follow-up radiographs. Three cortices were engaged in 66 patients (80%) and quadricortical fixation was performed in the remaining 16 patients (20%). The number of engaged cortices did not correlate with the clinical outcome and screw fracture. A single syndesmotic screw was used in 71 patients (86%. The mean AOFAS score in the group with intact screw (I) was 83; the scores in the group with broken screw (B) and removed screw (R) were 92.5 and 85.5, respectively. There was a statistically significant difference between the three groups: this was due to the difference between groups I and B; the difference between groups I and R and groups B and R were not statistically significant. There were no statistically significant differences in VAS results. There were no statistically significant differences in clinical outcome between the group with the screw retained and the group in which the screw was removed; however, the group with broken screws had the best clinical outcome based on AOFAS score. Widening of the syndesmosis after screw removal was not evident. We do not recommend routine syndesmosis screw removal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Biomechanical Comparison of Inter-fragmentary Compression Pressures: Lag Screw versus Herbert Screw for Anterior Odontoid Screw Fixation.

    PubMed

    Park, Jin-Woo; Kim, Kyoung-Tae; Sung, Joo-Kyung; Park, Seong-Hyun; Seong, Ki-Woong; Cho, Dae-Chul

    2017-09-01

    The purpose of the present study was to compare inter-fragmentary compression pressures after fixation of a simulated type II odontoid fracture with the headless compression Herbert screw and a half threaded cannulated lag screw. We compared inter-fragmentary compression pressures between 40- and 45-mm long 4.5-mm Herbert screws (n=8 and n=9, respectively) and 40- and 45-mm long 4.0-mm cannulated lag screws (n=7 and n=10, respectively) after insertion into rigid polyurethane foam test blocks (Sawbones, Vashon, WA, USA). A washer load cell was placed between the two segments of test blocks to measure the compression force. Because the total length of each foam block was 42 mm, the 40-mm screws were embedded in the cancellous foam, while the 45-mm screws penetrated the denser cortical foam at the bottom. This enabled us to compare inter-fragmentary compression pressures as they are affected by the penetration of the apical dens tip by the screws. The mean compression pressures of the 40- and 45-mm long cannulated lag screws were 50.48±1.20 N and 53.88±1.02 N, respectively, which was not statistically significant (p=0.0551). The mean compression pressures of the 40-mm long Herbert screw was 52.82±2.17 N, and was not statistically significant compared with the 40-mm long cannulated lag screw (p=0.3679). However, 45-mm Herbert screw had significantly higher mean compression pressure (60.68±2.03 N) than both the 45-mm cannulated lag screw and the 40-mm Herbert screw (p=0.0049 and p=0.0246, respectively). Our results showed that inter-fragmentary compression pressures of the Herbert screw were significantly increased when the screw tip penetrated the opposite dens cortical foam. This can support the generally recommended surgical technique that, in order to facilitate maximal reduction of the fracture gap using anterior odontoid screws, it is essential to penetrate the apical dens tip with the screw.

  15. Gain Modulation as a Mechanism for Coding Depth from Motion Parallax in Macaque Area MT

    PubMed Central

    Kim, HyungGoo R.; Angelaki, Dora E.

    2017-01-01

    Observer translation produces differential image motion between objects that are located at different distances from the observer's point of fixation [motion parallax (MP)]. However, MP can be ambiguous with respect to depth sign (near vs far), and this ambiguity can be resolved by combining retinal image motion with signals regarding eye movement relative to the scene. We have previously demonstrated that both extra-retinal and visual signals related to smooth eye movements can modulate the responses of neurons in area MT of macaque monkeys, and that these modulations generate neural selectivity for depth sign. However, the neural mechanisms that govern this selectivity have remained unclear. In this study, we analyze responses of MT neurons as a function of both retinal velocity and direction of eye movement, and we show that smooth eye movements modulate MT responses in a systematic, temporally precise, and directionally specific manner to generate depth-sign selectivity. We demonstrate that depth-sign selectivity is primarily generated by multiplicative modulations of the response gain of MT neurons. Through simulations, we further demonstrate that depth can be estimated reasonably well by a linear decoding of a population of MT neurons with response gains that depend on eye velocity. Together, our findings provide the first mechanistic description of how visual cortical neurons signal depth from MP. SIGNIFICANCE STATEMENT Motion parallax is a monocular cue to depth that commonly arises during observer translation. To compute from motion parallax whether an object appears nearer or farther than the point of fixation requires combining retinal image motion with signals related to eye rotation, but the neurobiological mechanisms have remained unclear. This study provides the first mechanistic account of how this interaction takes place in the responses of cortical neurons. Specifically, we show that smooth eye movements modulate the gain of responses of neurons in area MT in a directionally specific manner to generate selectivity for depth sign from motion parallax. We also show, through simulations, that depth could be estimated from a population of such gain-modulated neurons. PMID:28739582

  16. A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

    NASA Astrophysics Data System (ADS)

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark J.; McGregor, Douglas S.; Roberts, Jeremy A.

    2018-05-01

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminate background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Moreover, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.

  17. Correlation Between Corneal Button Size and Intraocular Pressure During Femtosecond Laser-Assisted Keratoplasty.

    PubMed

    Choi, Mihyun; Lee, Yong Eun; Whang, Woong-Joo; Yoo, Young-Sik; Na, Kyung-Sun; Joo, Choun-Ki

    2016-03-01

    To evaluate changes in intraocular pressure (IOP) in recipient and donor eyes during femtosecond laser-assisted keratoplasty (FLAK) and to assess for differences in the diameter of trephinated corneal buttons according to changes in pressure. Twenty porcine whole eyes (recipient model) and 20 porcine-corneoscleral rims (donor model) were prepared, and anterior chamber pressures were measured using a fiberoptic sensing device (Opsens, Quebec, Canada) during the femtosecond laser corneal cutting process. To determine the diameter of corneal buttons, 10 porcine whole eyes (recipient model) and 12 corneoscleral rims (donor model) of each baseline IOP were cut with the femtosecond laser programmed to the following pattern: "vertical side cut"; 1200 μm (depth), 8 mm (diameter). Digital photographs were obtained using microscopy and subsequently analyzed. The IOP (mean ± SD) for the recipient model was 10.2 (±0.9) mm Hg at baseline and ranged from 96.6 (±4.5) to ∼138.4 (±3.8) mm Hg during the corneal cutting process. This shows that the maximum IOP during FLAK increased 13.5 times compared with baseline. In the donor model, the mean pressure elevation from baseline artificial anterior chamber (AAC) pressure to corneal cutting was 15.8 (±5.4) mm Hg. This showed a positive correlation with baseline IOP [correlation coefficient (CC) = 0.827, P = 0.006]. As the baseline IOP in the recipient eye increased, trephinated corneal button size was reduced by up to 3.9% in diameter (CC = -0.945, P = 0.015). In addition, in donor eyes, the diameter was decreased by up to 11.7% as the baseline AAC pressure increased (CC = -0.934, P = 0.006). During the FLAK procedure, the IOP increases in both recipient and donor eyes. The diameter of the trephinated donor and recipient corneal buttons was decreased as the initial baseline IOP increased. Ophthalmic surgeons can determine the AAC pressure based on the baseline IOP in the recipient patient.

  18. A Geant4 evaluation of the Hornyak button and two candidate detectors for the TREAT hodoscope

    DOE PAGES

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark; ...

    2018-02-05

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminatemore » background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.« less

  19. Arthroscopically assisted reduction of acute acromioclavicular joint dislocation using a single double-button device: Medium-term clinical and radiological outcomes.

    PubMed

    Issa, S-P; Payan, C; Le Hanneur, M; Loriaut, P; Boyer, P

    2018-02-01

    Double-button devices for endoscopic management of acute acromioclavicular joint dislocation (ACJD) provide satisfactory short-term functional and radiological results. However, little exists in the literature regarding the long- and medium-term results of these implants, especially regarding the evolution of the acromioclavicular joint (ACJ). Satisfactory and steady long- and medium-term outcomes can be achieved in patients with acute ACJD undergoing endoscopically assisted ACJ repair using a single double-button device. A retrospective single-center study was conducted in patients with acute Rockwood III and IV ACJD treated endoscopically with a single double-button device from October 2008 to October 2010, allowing a minimum 5-year follow-up. Functional evaluation used Constant and Quick-DASH scores. Clinical evidence of dislocation recurrence was combined with bilateral Zanca views to assess coracoclavicular distance. Acromioclavicular osteoarthritis was evaluated on the Paxinos test and Zanca views. Nineteen of the 25 operated patients were seen at a mean 76.9±8.5 months' follow-up. Mean age was 34.4±8.3 years. Mean Constant and Quick-DASH scores were 96.2±5.1 and 0.9±1.6 points, respectively. Four patients had a recurrence of their initial dislocation, 3 of whom had positive Paxinos test, whereas the 15 patients without recurrence had a negative test (p=0.004). Five patients had radiological evidence of ACJ osteoarthritis: all 4 patients with recurrence and 1 without (p=0.001). Long- and medium-term radioclinical outcome of endoscopically assisted management of acute ACJD using a single double-button device seems to be satisfactory and steady over time. Recurrence of the initial dislocation appears to be related to onset of degenerative ACJ arthropathy. Therapeutic type IV-Retrospective case series. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  20. Differential sensory fMRI signatures in autism and schizophrenia: Analysis of amplitude and trial-to-trial variability.

    PubMed

    Haigh, Sarah M; Gupta, Akshat; Barb, Scott M; Glass, Summer A F; Minshew, Nancy J; Dinstein, Ilan; Heeger, David J; Eack, Shaun M; Behrmann, Marlene

    2016-08-01

    Autism and schizophrenia share multiple phenotypic and genotypic markers, and there is ongoing debate regarding the relationship of these two disorders. To examine whether cortical dynamics are similar across these disorders, we directly compared fMRI responses to visual, somatosensory and auditory stimuli in adults with autism (N=15), with schizophrenia (N=15), and matched controls (N=15). All participants completed a one-back letter detection task presented at fixation (to control attention) while task-irrelevant sensory stimulation was delivered to the different modalities. We focused specifically on the response amplitudes and the variability in sensory fMRI responses of the two groups, given the evidence of greater trial-to-trial variability in adults with autism. Both autism and schizophrenia individuals showed weaker signal-to-noise ratios (SNR) in sensory-evoked responses compared to controls (d>0.42), but for different reasons. For the autism group, the fMRI response amplitudes were indistinguishable from controls but were more variable trial-to-trial (d=0.47). For the schizophrenia group, response amplitudes were smaller compared to autism (d=0.44) and control groups (d=0.74), but were not significantly more variable (d<0.29). These differential group profiles suggest (1) that greater trial-to-trial variability in cortical responses may be specific to autism and is not a defining characteristic of schizophrenia, and (2) that blunted response amplitudes may be characteristic of schizophrenia. The relationship between the amplitude and the variability of cortical activity might serve as a specific signature differentiating these neurodevelopmental disorders. Identifying the neural basis of these responses and their relationship to the underlying genetic bases may substantially enlighten the understanding of both disorders. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Investigation of Optically Induced Avalanching in GaAs

    DTIC Science & Technology

    1989-06-01

    by Bovino , et al 4 to increase the hold off voltage. The button switch design of Fig. 4c has been used by several researchers5 ’ 7 to obtain the...ul Long flashover palh Figure 3b. 434 Optical Jlatlern a. Mourou Switch b. Bovino Switch c. Button Switch Figure 4. Photoconductive Switches...Technology and Devices Laboratory, ERADCOM (by L. Bovino , et. all) 4 • The deposition recipe for the contacts is 1) 50 ANi (provides contact to GaAs

  2. Design and Implementation of an Operations Module for the ARGOS paperless Ship System

    DTIC Science & Technology

    1989-06-01

    A. OPERATIONS STACK SCRIPTS SCRIPTS FOR STACK: operations * BACKGROUND #1: Operations * on openStack hide message box show menuBar pass openStack end... openStack ** CARD #1, BUTTON #1: Up ***** on mouseUp visual effect zoom out go to card id 10931 of stack argos end mouseUp ** CARD #1, BUTTON #2...STACK SCRIPTS SCRIPTS FOR STACK: Reports ** BACKGROUND #1: Operations * on openStack hie message box show menuBar pass openStack end openStack ** CARD #1

  3. Sealing Penetrating Eye Injuries Using Photoactivated Bonding

    DTIC Science & Technology

    2010-09-30

    on  corneal tissue. To evaluate inflammation all 15 rabbits will be euthanized with  phenobarbital . The  10 corneoscleral button of tissue will be...will be euthanized with  phenobarbital . The  corneoscleral button of tissue will be removed and divided into portions for paraffin and frozen sections

  4. Study of Psychological (and Associated Physiological) Effects on a Tank Crew Resulting from Being Buttoned Up

    DTIC Science & Technology

    1976-10-01

    should he made for either ixiternal storage or a means of voiding the urinal in a storage container in the compartment’. Development of-Adequate...upper temperature ranges fu- critical components of the M60 tank under desert storage and operational conditions. He found that the Wet Bulb Globe...five-gallon cans on the outside turret bustle racks. If buttoned-up operations for extended periods of time are envisioned, a built-in water storage

  5. Energy Saving in Electric Lighting for the United States Army.

    DTIC Science & Technology

    1979-10-05

    these reasons. Avoid devices such as power saving buttons which are to be placed in the sockets of incandescent bulbs. They are merely half-wave...using the button or a long-life bulb. Another device to avoid is the pulse or transient suppressor. This device, essentially a voltage clipper...arranged In a geo- metric pattern. It is used to shield a lamp from Lumen: A unit of light output from a lamp. view at certain angles to avoid glare from

  6. Far Forward Life Support System (FFLSS) Phase II

    DTIC Science & Technology

    2001-05-01

    button will clear audible, flashing , or constant red alarms. Pushing the Config button drops down to the Level 2 menu (bottom line of Figure 8). In...disabled. Again, with testing this audible noise can be disabled. The visual flashing or constant red cannot be disabled. Pushing Return goes back to Level...Calling PLOTPIXEL( x ,y) and PLOTLINE(xl,x2,yl,y2) is as simple as pushing the appropriate bytes (unsigned integers) onto the stack and jumping to the

  7. Retinotopic patterns of functional connectivity between V1 and large-scale brain networks during resting fixation

    PubMed Central

    Griffis, Joseph C.; Elkhetali, Abdurahman S.; Burge, Wesley K.; Chen, Richard H.; Bowman, Anthony D.; Szaflarski, Jerzy P.; Visscher, Kristina M.

    2016-01-01

    Psychophysical and neurobiological evidence suggests that central and peripheral vision are specialized for different functions. This specialization of function might be expected to lead to differences in the large-scale functional interactions of early cortical areas that represent central and peripheral visual space. Here, we characterize differences in whole-brain functional connectivity among sectors in primary visual cortex (V1) corresponding to central, near-peripheral, and far-peripheral vision during resting fixation. Importantly, our analyses reveal that eccentricity sectors in V1 have different functional connectivity with non-visual areas associated with large-scale brain networks. Regions associated with the fronto-parietal control network are most strongly connected with central sectors of V1, regions associated with the cingulo-opercular control network are most strongly connected with near-peripheral sectors of V1, and regions associated with the default mode and auditory networks are most strongly connected with far-peripheral sectors of V1. Additional analyses suggest that similar patterns are present during eyes-closed rest. These results suggest that different types of visual information may be prioritized by large-scale brain networks with distinct functional profiles, and provide insights into how the small-scale functional specialization within early visual regions such as V1 relates to the large-scale organization of functionally distinct whole-brain networks. PMID:27554527

  8. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating

    PubMed Central

    Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-01-01

    PURPOSE The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. MATERIALS AND METHODS Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 106 cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). RESULTS The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). CONCLUSION The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws. PMID:26576253

  9. Event related potentials during covert orientation of visual attention: effects of cue validity and directionality.

    PubMed

    Wright, M J; Geffen, G M; Geffen, L B

    1995-10-01

    Covert orientation of attention was studied in 30 adults who fixated warning cues and pressed a button at target onset. Directional cues (arrows) indicated the most probable (p = 0.8) side of target occurrence. Subjects responded fastest when validly cued, slowest to invalidly cued targets, and at an intermediate rate when the cue (a cross) was not directional. Directional cues took longer to evaluate (increased N1 and P2 latencies) and produced more focussed attention and greater response preparation (enhanced CNV and P3 amplitude) than non-directional cues. These findings indicate that the expectancy of a target can be manipulated by a spatial cue at three levels, sensory, attention, and response preparation, and lead to changes in the sensory perceptual processing of the target. Validly cued targets produced an increase in P1 amplitude reflecting attention enhanced sensory processing whereas invalidly cued targets increased N1 and P3 amplitudes reflecting the re-orientation of attention, and further processing and updating of information required of low probability stimuli respectively. P3 latency to invalidly cued targets was also delayed reflecting the additional processes required to shift attention to a new location. The P3 latency validity effect was smaller than that found for response time suggesting response execution may also be affected by spatial attention.

  10. The structure of affective action representations: temporal binding of affective response codes.

    PubMed

    Eder, Andreas B; Müsseler, Jochen; Hommel, Bernhard

    2012-01-01

    Two experiments examined the hypothesis that preparing an action with a specific affective connotation involves the binding of this action to an affective code reflecting this connotation. This integration into an action plan should lead to a temporary occupation of the affective code, which should impair the concurrent representation of affectively congruent events, such as the planning of another action with the same valence. This hypothesis was tested with a dual-task setup that required a speeded choice between approach- and avoidance-type lever movements after having planned and before having executed an evaluative button press. In line with the code-occupation hypothesis, slower lever movements were observed when the lever movement was affectively compatible with the prepared evaluative button press than when the two actions were affectively incompatible. Lever movements related to approach and avoidance and evaluative button presses thus seem to share a code that represents affective meaning. A model of affective action control that is based on the theory of event coding is discussed.

  11. Investigation of He-W interactions using DiMES on DIII-D

    NASA Astrophysics Data System (ADS)

    Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.; Briesemeister, A. R.; Corr, C.; De Temmerman, G.; Kluth, P.; Lasnier, C. J.; McLean, A. G.; Pace, D. C.; Pitts, R. A.; Schmitz, O.; Thompson, M.; Winters, V.

    2016-02-01

    Tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225-850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in the surface of W buttons after only a single DIII-D (3 s, ˜150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04-0.1 MJ m-2.

  12. eButton: A Wearable Computer for Health Monitoring and Personal Assistance

    PubMed Central

    Sun, Mingui; Burke, Lora E.; Mao, Zhi-Hong; Chen, Yiran; Chen, Hsin-Chen; Bai, Yicheng; Li, Yuecheng; Li, Chengliu; Jia, Wenyan

    2014-01-01

    Recent advances in mobile devices have made profound changes in people's daily lives. In particular, the impact of easy access of information by the smartphone has been tremendous. However, the impact of mobile devices on healthcare has been limited. Diagnosis and treatment of diseases are still initiated by occurrences of symptoms, and technologies and devices that emphasize on disease prevention and early detection outside hospitals are under-developed. Besides healthcare, mobile devices have not yet been designed to fully benefit people with special needs, such as the elderly and those suffering from certain disabilities, such blindness. In this paper, an overview of our research on a new wearable computer called eButton is presented. The concepts of its design and electronic implementation are described. Several applications of the eButton are described, including evaluating diet and physical activity, studying sedentary behavior, assisting the blind and visually impaired people, and monitoring older adults suffering from dementia. PMID:25340176

  13. A novel wearable smart button system for fall detection

    NASA Astrophysics Data System (ADS)

    Zhuang, Wei; Sun, Xiang; Zhi, Yueyan; Han, Yue; Mao, Hande

    2017-05-01

    Fall has been the second most cause of accidental injury to death in the world. It has been a serious threat to the physical and mental health of the elders. Therefore, developing wearable node system with fall detecting ability has become increasingly pressing at present. A novel smart button for long-term fall detection is proposed in this paper, which is able to accurately monitor the falling behavior, and sending warning message online as well. The smart button is based on the tri-axis acceleration sensor which is used to collect the body motion signals. By using the statistical metrics of acceleration characteristics, a new SVM classification algorithm with high positive accuracy and stability is proposed so as to classify the falls and activities of daily living, and the results can be real-time displayed on Android based mobile phone. The experiments show that our wearable node system can continuously monitor the falling behavior with positive rate 94.8%.

  14. Field evaluation of personal sampling methods for multiple bioaerosols.

    PubMed

    Wang, Chi-Hsun; Chen, Bean T; Han, Bor-Cheng; Liu, Andrew Chi-Yeu; Hung, Po-Chen; Chen, Chih-Yong; Chao, Hsing Jasmine

    2015-01-01

    Ambient bioaerosols are ubiquitous in the daily environment and can affect health in various ways. However, few studies have been conducted to comprehensively evaluate personal bioaerosol exposure in occupational and indoor environments because of the complex composition of bioaerosols and the lack of standardized sampling/analysis methods. We conducted a study to determine the most efficient collection/analysis method for the personal exposure assessment of multiple bioaerosols. The sampling efficiencies of three filters and four samplers were compared. According to our results, polycarbonate (PC) filters had the highest relative efficiency, particularly for bacteria. Side-by-side sampling was conducted to evaluate the three filter samplers (with PC filters) and the NIOSH Personal Bioaerosol Cyclone Sampler. According to the results, the Button Aerosol Sampler and the IOM Inhalable Dust Sampler had the highest relative efficiencies for fungi and bacteria, followed by the NIOSH sampler. Personal sampling was performed in a pig farm to assess occupational bioaerosol exposure and to evaluate the sampling/analysis methods. The Button and IOM samplers yielded a similar performance for personal bioaerosol sampling at the pig farm. However, the Button sampler is more likely to be clogged at high airborne dust concentrations because of its higher flow rate (4 L/min). Therefore, the IOM sampler is a more appropriate choice for performing personal sampling in environments with high dust levels. In summary, the Button and IOM samplers with PC filters are efficient sampling/analysis methods for the personal exposure assessment of multiple bioaerosols.

  15. Beam Diagnostics of the Compton Scattering Chamber in Jefferson Lab's Hall C

    NASA Astrophysics Data System (ADS)

    Faulkner, Adam; I&C Group Collaboration

    2013-10-01

    Upcoming experimental runs in Hall C will utilize Compton scattering, involving the construction and installation of a rectangular beam enclosure. Conventional cylindrical stripline-style Beam Position Monitors (BPMs) are not appropriate due to their form factor; therefore to facilitate measurement of position, button-style BPMs are being considered due to the ease of placement within the new beam enclosure. Button BPM experience is limited at JLAB, so preliminary measurements are needed to characterize the field response, and guide the development of appropriate algorithms for the Analog to Digital receiver systems. -field mapping is performed using a Goubau Line (G-Line), which employs a surface wave to mimic the electron beam, helping to avoid problems associated with vacuum systems. Potential algorithms include simplistic 1/r modeling (-field mapping), look-up-tables, as well as a potential third order power series fit. In addition, the use of neural networks specifically the multi-layer Perceptron will be examined. The models, sensor field maps, and utility of the neural network will be presented. Next steps include: modification of the control algorithm, as well as to run an in-situ test of the four Button electrodes inside of a mock beam enclosure. The analysis of the field response using Matlab suggests the button BPMs are accurate to within 10 mm, and may be successful for beam diagnostics in Hall C. More testing is necessary to ascertain the limitations of the new electrodes. The National Science Foundation, Old Dominion University, The Department of Energy, and Jefferson Lab.

  16. Design and Implementation of an fMRI Study Examining Thought Suppression in Young Women with, and At-risk, for Depression

    PubMed Central

    Carew, Caitlin L.; Tatham, Erica L.; Milne, Andrea M.; MacQueen, Glenda M.; Hall, Geoffrey B.C.

    2015-01-01

    Ruminative brooding is associated with increased vulnerability to major depression. Individuals who regularly ruminate will often try to reduce the frequency of their negative thoughts by actively suppressing them. We aim to identify the neural correlates underlying thought suppression in at-risk and depressed individuals. Three groups of women were studied; a major depressive disorder group, an at-risk group (having a first degree relative with depression) and controls. Participants performed a mixed block-event fMRI paradigm involving thought suppression, free thought and motor control periods. Participants identified the re-emergence of “to-be-suppressed” thoughts (“popping” back into conscious awareness) with a button press. During thought suppression the control group showed the greatest activation of the dorsolateral prefrontal cortex, followed by the at-risk, then depressed group. During the re-emergence of intrusive thoughts compared to successful re-suppression of those thoughts, the control group showed the greatest activation of the anterior cingulate cortices, followed by the at-risk, then depressed group. At-risk participants displayed anomalies in the neural regulation of thought suppression resembling the dysregulation found in depressed individuals. The predictive value of these changes in the onset of depression remains to be determined. PMID:26067869

  17. The Effect of Spatial Smoothing on Representational Similarity in a Simple Motor Paradigm

    PubMed Central

    Hendriks, Michelle H. A.; Daniels, Nicky; Pegado, Felipe; Op de Beeck, Hans P.

    2017-01-01

    Multi-voxel pattern analyses (MVPA) are often performed on unsmoothed data, which is very different from the general practice of large smoothing extents in standard voxel-based analyses. In this report, we studied the effect of smoothing on MVPA results in a motor paradigm. Subjects pressed four buttons with two different fingers of the two hands in response to auditory commands. Overall, independent of the degree of smoothing, correlational MVPA showed distinctive patterns for the different hands in all studied regions of interest (motor cortex, prefrontal cortex, and auditory cortices). With regard to the effect of smoothing, our findings suggest that results from correlational MVPA show a minor sensitivity to smoothing. Moderate amounts of smoothing (in this case, 1−4 times the voxel size) improved MVPA correlations, from a slight improvement to large improvements depending on the region involved. None of the regions showed signs of a detrimental effect of moderate levels of smoothing. Even higher amounts of smoothing sometimes had a positive effect, most clearly in low-level auditory cortex. We conclude that smoothing seems to have a minor positive effect on MVPA results, thus researchers should be mindful about the choices they make regarding the level of smoothing. PMID:28611726

  18. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    PubMed

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon-deficient, complete distal biceps rupture model, acellular dermal allograft augmentation restored the native tendon's biomechanical properties at time zero. The grafted tissue-deficient model demonstrated no significant differences in the load to failure and gap formation compared with the native tendon. As expected, dermal augmentation of attritional tendon repair increased the load to failure and stiffness as well as decreased displacement compared with the ungrafted tissue-deficient model. Tendons with their native width showed no statistical difference or negative biomechanical consequences of dermal augmentation. Dermal augmentation of the distal biceps is a biomechanically feasible option for patients with an attritionally thinned-out tendon.

  19. Re-Engineering the United States Marine Corps’ Enlisted Assignment Model (EAM)

    DTIC Science & Technology

    1998-06-01

    and Execution button opens the switchboard in Figure 12. This form accesses all of the VBA code that is associated with this form and the code that...the prototype to prompt the user and to inform him of what he is about to do. Each of the buttons that are on these forms is connected to an SQL ...into the field for building a rule are the values 2;3;4;5;6;7. The user can enter an SQL statement that would determine the values or the user could

  20. ALLTEM System User’s Manual, Munitions Management Projects, ALLTEM Multi-Axis Electromagnetic Induction System Demonstration and Validation, Version 1.0

    DTIC Science & Technology

    2012-03-05

    Alarm button. Under the GPS frame are two smaller frames. On the left is a frame with buttons labeled Tractor Guidance and Acquisition Error... GPS ) and the Attitude Heading Reference System (AHRS) data. 5.2 Using the Data Acquisition Simulator Software The simulator and a practice set... acquisition for one polarity of the TX (33ms dead band for relay switching + 33 ms of waveforms). When the GPS is being used this is usually “1”, but may be

  1. Biomechanical measurements of stopping and stripping torques during screw insertion in five types of human and artificial humeri.

    PubMed

    Aziz, Mina Sr; Tsuji, Matthew Rs; Nicayenzi, Bruce; Crookshank, Meghan C; Bougherara, Habiba; Schemitsch, Emil H; Zdero, Radovan

    2014-05-01

    During orthopedic surgery, screws are inserted by "subjective feel" in humeri for fracture fixation, that is, stopping torque, while trying to prevent accidental over-tightening that causes screw-bone interface failure, that is, stripping torque. However, no studies exist on stopping torque, stripping torque, or stopping/stripping torque ratio in human or artificial humeri. This study evaluated five types of humeri, namely, human fresh-frozen (n = 19), human embalmed (n = 18), human dried (n = 15), artificial "normal" (n = 13), and artificial "osteoporotic" (n = 13). An orthopedic surgeon used a torque screwdriver to insert 3.5-mm-diameter cortical screws into humeral shafts and 6.5-mm-diameter cancellous screws into humeral heads by "subjective feel" to obtain stopping and stripping torques. The five outcome measures were raw and normalized stopping torque, raw and normalized stripping torque, and stopping/stripping torque ratio. Normalization was done as raw torque/screw-bone interface area. For "gold standard" fresh-frozen humeri, cortical screw tests yielded averages of 1312 N mm (raw stopping torque), 30.4 N/mm (normalized stopping torque), 1721 N mm (raw stripping torque), 39.0 N/mm (normalized stripping torque), and 82% (stopping/stripping torque ratio). Similarly, fresh-frozen humeri gave cancellous screw average results of 307 N mm (raw stopping torque), 0.9 N/mm (normalized stopping torque), 392 N mm (raw stripping torque), 1.2 N/mm (normalized stripping torque), and 79% (stopping/stripping torque ratio). Of the five cortical screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in four cases (embalmed), three cases (dried), four cases (artificial "normal"), and four cases (artificial "osteoporotic"). Of the five cancellous screw parameters for fresh-frozen humeri versus other groups, statistical equivalence (p ≥ 0.05) occurred in five cases (embalmed), one case (dried), one case (artificial "normal"), and zero cases (artificial "osteoporotic"). Stopping/stripping torque ratios were relatively constant for all groups at 77%-88% (cortical screws) and 79%-92% (cancellous screws). © IMechE 2014.

  2. The feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus: a retrospective analysis of eleven patients.

    PubMed

    Zhang, Xin-Liang; Huang, Da-Geng; Wang, Xiao-Dong; Zhu, Jin-Wen; Li, Yi-Bing; He, Bao-Rong; Hao, Ding-Jun

    2017-04-01

    Ponticulus posticus is a common anatomic variation that can be mistaken for a broad posterior arch during C1 pedicle screw placement. When the atlas lateral mass screws are placed via the posterior arch, injury to the vertebral artery may result. To our knowledge, there are few clinical studies that have analyzed the feasibility of C1 pedicle screw fixation in patients with ponticulus posticus, in clinical practice. To evaluate the feasibility of inserting a C1 pedicle screw in patients with ponticulus posticus. Between January 2008 and January 2012, 11 consecutive patients with atlantoaxial instability, and with a ponticulus posticus at C1, underwent posterior fusion surgery in our institution. According to preoperative computed tomography (CT) reconstruction, a complete ponticulus posticus was found unilaterally in nine patients and bilaterally in two. Postoperative CT reconstructive imaging was performed to assess whether C1 pedicle screw placement was successful. Patients were followed up at regular intervals and evaluated for symptoms of ponticulus posticus syndrome. Thirteen C1 pedicles (atlas vertebral artery groove), each with a complete ponticulus posticus, were successfully inserted with thirteen 3.5- or 4.0-mm diameter pedicle screws, without resection of the bony anomaly. No intraoperative complications (venous plexus, vertebral artery, or spinal cord injury) occurred. The mean follow-up period was 21 (range 14-30) months. Postoperative CT reconstructive images showed that all 13 pedicle screws were inserted in the C1 pedicles without destruction of the atlas pedicle cortical bone. In the follow-up period, none of the patients demonstrated clinical symptoms of ponticulus posticus syndrome or developed bone fusion. Three-dimensional CT imaging should be considered prior to C1 pedicle screw fixation in patients with ponticulus posticus, to avoid mistaking the ponticulus posticus for a widened dorsal arch of the atlas. If there is no ponticulus posticus syndrome preoperatively, C1 pedicle screw fixation can be successfully performed without removing the bony anomaly.

  3. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?

    PubMed

    Shah, S; Kim, S Y R; Dubov, A; Schemitsch, E H; Bougherara, H; Zdero, R

    2011-09-01

    Femoral shaft fractures after total hip arthroplasty (THA) remain a serious problem, since there is no optimal surgical repair method. Virtually all studies that examined surgical repair methods have done so clinically or experimentally. The present study assessed injury patterns computationally by developing three-dimensional (3D) finite element (FE) models that were validated experimentally. The investigation evaluated three different constructs for the fixation of Vancouver B1 periprosthetic femoral shaft fractures following THA. Experimentally, three bone plate repair methods were applied to a synthetic femur with a 5 mm fracture gap near the tip of a total hip implant. Repair methods were identical distal to the fracture gap, but used cables only (construct A), screws only (construct B), or cables plus screws (construct C) proximal to the fracture gap. Specimens were oriented in 15 degrees adduction to simulate the single-legged stance phase of walking, subjected to 1000 N of axial force, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic 3D FE model was developed to mimic experiments. Results showed excellent agreement between experimental and FE strains, yielding a Pearson linearity coefficient, R2, of 0.92 and a slope for the line of best data fit of 1.06. FE-computed axial stiffnesses were 768 N/mm (construct A), 1023 N/mm (construct B), and 1102 N/mm (construct C). FE surfaces stress maps for cortical bone showed Von Mises stresses, excluding peaks, of 0-8 MPa (construct A), 0-15 MPa (construct B), and 0-20 MPa (construct C). Cables absorbed the majority of load, followed by the plates and then the screws. Construct A yielded peak stress at one of the empty holes in the plate. Constructs B and C had similar bone stress patterns, and can achieve optimal fixation.

  4. Evaluation of the results from proximal fixation of uncemented conical femoral components in Dorr type C femurs☆☆☆

    PubMed Central

    Ahmad Hatem, Munif; Ferreira da Luz, Bernardo; Nishimoto Nishi, Rodrigo; Gilberto Cimbalista de Alencar, Paulo

    2014-01-01

    Objective To evaluate the results from proximal fixation of uncemented conical femoral components in patients with a type C proximal femur and compare them with the results obtained from type A and B femurs. Methods This was a retrospective study on 87 patients with 90 uncemented total hip arthroplasty procedures. Three patients (three hips) were excluded because their follow-up lasted for less than two years. The follow-up ranged from 2 to 4.3 years and the mean was 2.8 years. The Bicontact femoral implant model was used. The preoperative radiographs were evaluated, the femurs were classified as Dorr types A, B or C and the cortical indices were measured. The patients were evaluated clinically by means of the Harris Hip Score (HHS), before the surgery and at the last follow-up. The sequences of postoperative radiographs were compared regarding stability, complications and any signs of osseointegration of the femoral prosthesis. Results Among the 87 hips with follow-up greater than two years, 32 femurs were type A (37%), 37 type B (42%) and 18 type C (21%). Before the operation, the mean HHS was 39.4 for types A and B and 38.8 for type C. At the last follow-up, the mean HHS was 89.8 for types A and B and 86 for type C. None of the 87 femoral components had been revised by the time of the last follow-up; all of them were considered stable. In 86 cases, the radiographs showed signs of osseointegration. Conclusion There were no significant differences in the clinical results or in the fixation (and osseointegration) of conical uncemented femoral prostheses with proximal porosity, among femurs with different types of femoral morphology according to the Dorr classification. This conclusion may vary if another implant model were to be used. PMID:26229810

  5. [Midcarpal arthrodesis with cortical bolting chip for treatment of grade II/III scaphoid non-union and scapholunate advanced collapse].

    PubMed

    Zeplin, P H; Kuhfuss, I

    2009-06-01

    These case reports describe a mediocarpal arthrodesis with excision of the scaphoid using a cortical bolting chip and screw fixation instead of the use of Kirschner wires or Spider plates. Four patients with a symptomatic SLAC/SLAC-wrist >or= grade II were treated. The evaluation occurred six months later. For the evaluation the Cooney and Bussey as well as DASH scores were used (pain, strength, range of motion, functional status, possible limitations of quality of life, subjective perception of the patient). The radiological evaluation was performed by conventional wrist X-ray in two projections. All patients were pain-free after the operation. From the radiological point of view a complete osseous consolidation has set in. The mean strength six months after surgical intervention was 53 % (preoperative 52 %) and the total range of motion 47 % (preoperative 59 %) compared to the opposite side. The Cooney and Bussey scores were at 69 (+ 25 %) and the DASH score at 44 (- 28 %) points. In case of an SNAC/SLAC-wrist a motion-preserving operation should always be given preference to a wrist stiffening procedure. The modified mid-carpal partial arthrodesis is an alternative operating procedure for the treatment of SNAC/SLAC-wrists in stage II/III. However, a higher number of cases and comparative studies are needed to confirm this concept.

  6. Surface structural damage study in cortical bone due to medical drilling.

    PubMed

    Tavera R, Cesar G; De la Torre-I, Manuel H; Flores-M, Jorge M; Hernandez M, Ma Del Socorro; Mendoza-Santoyo, Fernando; Briones-R, Manuel de J; Sanchez-P, Jorge

    2017-05-01

    A bone's fracture could be produced by an excessive, repetitive, or sudden load. A regular medical practice to heal it is to fix it in two possible ways: external immobilization, using a ferule, or an internal fixation, using a prosthetic device commonly attached to the bone by means of surgical screws. The bone's volume loss due to this drilling modifies its structure either in the presence or absence of a fracture. To observe the bone's surface behavior caused by the drilling effects, a digital holographic interferometer is used to analyze the displacement surface's variations in nonfractured post-mortem porcine femoral bones. Several nondrilled post-mortem bones are compressed and compared to a set of post-mortem bones with a different number of cortical drillings. During each compression test, a series of digital interferometric holograms were recorded using a high-speed CMOS camera. The results are presented as pseudo 3D mesh displacement maps for comparisons in the physiological range of load (30 and 50 lbs) and beyond (100, 200, and 400 lbs). The high resolution of the optical phase gives a better understanding about the bone's microstructural modifications. Finally, a relationship between compression load and bone volume loss due to the drilling was observed. The results prove that digital holographic interferometry is a viable technique to study the conditions that avoid the surgical screw from loosening in medical procedures of this kind.

  7. Ankle arthrodesis with bone graft after distal tibia resection for bone tumors.

    PubMed

    Campanacci, Domenico Andrea; Scoccianti, Guido; Beltrami, Giovanni; Mugnaini, Marco; Capanna, Rodolfo

    2008-10-01

    Treatment of distal tibial tumors is challenging due to the scarce soft tissue coverage of this area. Ankle arthrodesis has proven to be an effective treatment in primary and post-traumatic joint arthritis, but few papers have addressed the feasibility and techniques of ankle arthrodesis in tumor surgery after long bone resections. Resection of the distal tibia and reconstruction by ankle fusion using non-vascularized structural bone grafts was performed in 8 patients affected by malignant (5 patients) or aggressive benign (3 patients) tumors. Resection length of the tibia ranged from 5 to 21 cm. Bone defects were reconstructed with cortical structural autografts (from contralateral tibia) or allografts or both, plus autologous bone chips. Fixation was accomplished by antegrade nailing (6 cases) or plating (2~cases). All the arthrodesis successfully healed. At followup ranging from 23 to 113 months (average 53.5), all patients were alive. One local recurrence was observed with concomitant deep infection (a below-knee amputation was performed). Mean functional MSTS score of the seven available patients was 80.4% (range, 53 to 93). Resection of the distal tibia and arthrodesis of the ankle with non-vascularized structural bone grafts, combined with autologous bone chips, can be an effective procedure in bone tumor surgery with durable and satisfactory functional results. In shorter resections, autologous cortical structural grafts can be used; in longer resections, allograft structural bone grafts are needed.

  8. Three-Dimensional Analysis of the Contact Pattern between the Cortical Bone and Femoral Prosthesis after Cementless Total Hip Arthroplasty

    PubMed Central

    Mishima, Hajime; Sugaya, Hisashi; Nishino, Tomofumi; Yamazaki, Masashi

    2016-01-01

    The cementless stem Excia (B. Braun, Melsungen, Germany) implant has a rectangular cross-sectional shape with back-and-forth flanges and a plasma-sprayed, dicalcium phosphate dihydrate coating from the middle to proximal portion to increase initial fixation and early bone formation. Here, the conformity of the Excia stem to the femoral canal morphology was three-dimensionally assessed using computed tomography. Forty-three patients (45 hips) were examined after primary total hip arthroplasty with a mean follow-up of 27 ± 3 months (range: 24–36 months). Spot welds occurred at zone 2 in 16 hips and at zone 6 in 24 hips, with 83% (20/24 hips) of those occurring within 3 months after surgery. First- (n = 12 hips), second- (n = 32), and third- (n = 1) degree stress shielding were observed. The stem was typically in contact with the cortical bone in the anterolateral mid-portion (100%) and posteromedial distal portions (85%). Stress shielding did not progress, even in cases where the stems were in contact with the distal portions. The anterior flange was in contact with the bone in all cases. The stability of the mid-lateral portion with the dicalcium phosphate dihydrate coating and the anterior flange may have inhibited the progression of stress shielding beyond the second degree. PMID:26881087

  9. Analysis of plastic deformation in cortical bone after insertion of coated and non-coated self-tapping orthopaedic screws.

    PubMed

    Koistinen, A P; Korhonen, H; Kiviranta, I; Kröger, H; Lappalainen, R

    2011-07-01

    Insertion of internal fracture fixation devices, such as screws, mechanically weakens the bone. Diamond-like carbon has outstanding tribology properties which may decrease the amount of damage in tissue. The purpose of this study was to investigate methods for quantification of cortical bone damage after orthopaedic bone screw insertion and to evaluate the effect of surface modification on tissue damage. In total, 48 stainless steel screws were inserted into cadaver bones. Half of the screws were coated with a smooth amorphous diamond coating. Geometrical data of the bones was determined by peripheral quantitative computed tomography. Thin sections of the bone samples were prepared after screw insertion, and histomorphometric evaluation of damage was performed on images obtained using light microscopy. Micro-computed tomography and scanning electron microscopy were also used to examine tissue damage. A positive correlation was found between tissue damage and the geometric properties of the bone. The age of the cadaver significantly affected the bone mineral density, as well as the damage perimeter and diameter of the screw hole. However, the expected positive effect of surface modification was probably obscured by large variations in the results and, thus, statistically significant differences were not found in this study. This can be explained by natural variability in bone tissue, which also made automated image analysis difficult.

  10. Pathophysiology of esophageal impairment due to button battery ingestion.

    PubMed

    Völker, Johannes; Völker, Christine; Schendzielorz, Philipp; Schraven, Sebastian P; Radeloff, Andreas; Mlynski, Robert; Hagen, Rudolf; Rak, Kristen

    2017-09-01

    The increased use of button batteries with high energy densities in devices of daily life presents a high risk of injury, especially for toddlers and young children. If an accidental ingestion of a button battery occurs, this foreign body can become caught in the constrictions of the esophagus and cause serious damage to the adjacent tissue layers. The consequences can be ulcerations, perforations with fistula formation and damage to the surrounding anatomical structures. In order to gain a better understanding of the pathophysiology after ingestion, we carried out systematic studies on fresh preparations of porcine esophagi. The lithium button battery type CR2032, used most frequently in daily life, was exposed in preparations of porcine esophagi and incubated under the addition of artificial saliva at 37 °C. A total of eight esophagi were analysed by different methods. Measurements of the pH value around the battery electrodes and histological studies of the tissue damage were carried out after 0.5-24 h exposure time. In addition, macroscopic time-lapse images were recorded. Measurements of the battery voltage and the course of the electric current supplemented the experiments. The investigations showed that the batteries caused an electrolysis reaction in the moist environment. The positive electrode formed an acidic and the negative electrode a basic medium. Consequently, a coagulation necrosis at the positive pole, and a deep colliquation necrosis at the minus pole occurred. After an exposure time of 12 h, tissue damage caused by the lye corrosion was observed on the side of the negative electrode up to the lamina muscularis. The corrosion progressed up to the final exposure time of 24 h, but the batteries still had sufficient residual voltage, such that further advancing damage would be expected. Button battery ingestion in humans poses an acute life-threatening danger and immediate endoscopic removal of the foreign body is essential. After only 2 h exposure time, significant damage to the tissue could be detected, which progressed continuously to complete esophageal perforation. The primary prevention of battery ingestion is therefore of particular importance. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Transient human auditory cortex activation during volitional attention shifting

    PubMed Central

    Uhlig, Christian Harm; Gutschalk, Alexander

    2017-01-01

    While strong activation of auditory cortex is generally found for exogenous orienting of attention, endogenous, intra-modal shifting of auditory attention has not yet been demonstrated to evoke transient activation of the auditory cortex. Here, we used fMRI to test if endogenous shifting of attention is also associated with transient activation of the auditory cortex. In contrast to previous studies, attention shifts were completely self-initiated and not cued by transient auditory or visual stimuli. Stimuli were two dichotic, continuous streams of tones, whose perceptual grouping was not ambiguous. Participants were instructed to continuously focus on one of the streams and switch between the two after a while, indicating the time and direction of each attentional shift by pressing one of two response buttons. The BOLD response around the time of the button presses revealed robust activation of the auditory cortex, along with activation of a distributed task network. To test if the transient auditory cortex activation was specifically related to auditory orienting, a self-paced motor task was added, where participants were instructed to ignore the auditory stimulation while they pressed the response buttons in alternation and at a similar pace. Results showed that attentional orienting produced stronger activity in auditory cortex, but auditory cortex activation was also observed for button presses without focused attention to the auditory stimulus. The response related to attention shifting was stronger contralateral to the side where attention was shifted to. Contralateral-dominant activation was also observed in dorsal parietal cortex areas, confirming previous observations for auditory attention shifting in studies that used auditory cues. PMID:28273110

  12. Correlating bilayer tablet delamination tendencies to micro-environmental thermodynamic conditions during pan coating.

    PubMed

    Zacour, Brian M; Pandey, Preetanshu; Subramanian, Ganeshkumar; Gao, Julia Z; Nikfar, Faranak

    2014-06-01

    The objective of this study was to determine the impact that the micro-environment, as measured by PyroButton data loggers, experienced by tablets during the pan coating unit operation had on the layer adhesion of bilayer tablets in open storage conditions. A full factorial design of experiments (DOE) with three center points was conducted to study the impact of final tablet hardness, film coating spray rate and film coating exhaust temperature on the delamination tendencies of bilayer tablets. PyroButton data loggers were placed (fixed) at various locations in a pan coater and were also allowed to freely move with the tablet bed to measure the micro-environmental temperature and humidity conditions of the tablet bed. The variance in the measured micro-environment via PyroButton data loggers accounted for 75% of the variance in the delamination tendencies of bilayer tablets on storage (R(2 )= 0.75). A survival analysis suggested that tablet hardness and coating spray rate significantly impacted the delamination tendencies of the bilayer tablets under open storage conditions. The coating exhaust temperature did not show good correlation with the tablets' propensity to crack indicating that it was not representative of the coating micro-environment. Models created using data obtained from the PyroButton data loggers outperformed models created using primary DOE factors in the prediction of bilayer tablet strength, especially upon equipment or scale transfers. The coating micro-environment experienced by tablets during the pan coating unit operation significantly impacts the strength of the bilayer interface of tablets on storage.

  13. Esophageal lesions following button-battery ingestion in children: Analysis of causes and proposals for preventive measures.

    PubMed

    Lahmar, J; Célérier, C; Garabédian, E N; Couloigner, V; Leboulanger, N; Denoyelle, F

    2018-04-01

    To study recent cases of esophageal injury due to button-battery ingestion in children presenting in pediatric ENT emergency departments of the Paris area of France (Île-de-France region), in order to propose appropriate preventive measures. A retrospective descriptive single-center study included all children under 15 years of age, presenting in pediatric ENT emergency departments between January 2008 and April 2014 for button-battery ingestion with esophageal impaction requiring emergency removal. Twenty-two boys and 4 girls, with a median age of 25 months, were included. Twenty-five of the 26 batteries had diameters of 20mm or more. Median esophageal impaction time was 7 hours 30 minutes (range, 2 to 72 hours). The complications rate was 23%. Mean hospital stay cost was €38,751 (range, €5130-119,737). The origin of the battery was known in 23 of the 26 cases: remote control without screw-secured compartment (42.3%), open battery pack (15.4%), children's toy (15.3%), camera (7.7%), watch (1 case) and hearing aid without screw-secured compartment (1 case). Esophageal lesions due to ingestion of button-batteries in children are almost always due to batteries larger than 20mm in diameter, mostly from devices with a poorly protected compartment, or batteries that are not individually packaged. These lesions cause serious complications in a quarter of cases and their management entails high health costs. Legislation requiring screw-secured compartments and individual blisters for batteries could have prevented 69.2% of the ingestions. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  14. User interface customization on Endoscopy Department Mini-PACS and its impact on examination workflow

    NASA Astrophysics Data System (ADS)

    Osada, Masakazu; Kaise, Mitsuru; Ozeki, Takeshi; Tsunakawa, Hirofumi; Tsunakawa, Kiyoshi; Takayanagi, Takashi; Suzuki, Nobuaki; Miwa, Jun; Ohta, Yasuhiko; Kanai, Koichi

    1999-07-01

    We have proposed a new user interface with workflow customization, implemented and evaluted in Endoscopy Department Mini-PACS that has been introduced and routinely used for two years at Toshiba General Hospital. We have set some task at endoscopy image acquisition units during examinations for two different types of user interfaces and compared performance. One is a command-button based operation using a remote control, and another is that with eight graphic buttons which are displayed on a CRT monitor and can be customized. Results of the two-year study show that mean number of input diagnosis codes per examination with graphic and customized interface is significantly greater than that with conventional interface. Also, mean time to complete one upper gastric endoscopy examination with new user interface is about 17 percent less than that with conventional interface. These result suggest that systems with the visualized and customized operation and feedback encourages physicians to use more functions and to compete tasks more efficiently than systems with conventional command-button based user interfaces.

  15. Concepts for multi-IFU robotic positioning systems

    NASA Astrophysics Data System (ADS)

    Miziarski, Stan; Brzeski, Jurek; Bland Hawthorn, Joss; Gilbert, James; Goodwin, Michael; Heijmans, Jeroen; Horton, Anthony; Lawrence, Jon; Saunders, Will; Smith, Greg A.; Staszak, Nicholas

    2012-09-01

    Following the successful commissioning of SAMI (Sydney-AAO Multi-object IFU) the AAO has undertaken concept studies leading to a design of a new instrument for the AAT (Hector). It will use an automated robotic system for the deployment of fibre hexabundles to the focal plane. We have analysed several concepts, which could be applied in the design of new instruments or as a retrofit to existing positioning systems. We look at derivatives of Starbugs that could handle a large fibre bundle as well as modifications to pick and place robots like 2dF or OzPoz. One concept uses large magnetic buttons that adhere to a steel field plate with substantial force. To move them we replace the gripper with a pneumatic device, which engages with the button and injects it with compressed air, thus forming a magnet preloaded air bearing allowing virtually friction-less repositioning of the button by a gantry or an R-Theta robot. New fibre protection, guiding and retraction systems are also described. These developments could open a practical avenue for the upgrade to a number of instruments.

  16. Early event-related brain potentials that reflect interest for content information in the media.

    PubMed

    Adachi, Shinobu; Morikawa, Koji; Nittono, Hiroshi

    2012-03-28

    This study investigated the relationship between event-related brain potentials (ERPs) to abridged content information in the media and the subsequent decisions to view the full content. Student volunteers participated in a task that simulated information selection on the basis of the content information. Screenshots of television clips and headlines of news articles on the Web were used as content information for the image condition and the headline condition, respectively. Following presentation of a stimulus containing content information, participants decided whether or not they would view the full content by pressing a select or a reject button. When the select button was pressed, participants were presented with a television clip or a news article. When the reject button was pressed, participants continued on to the next trial, without viewing further. In comparison with rejected stimuli, selected stimuli elicited a larger negative component, with a peak latency of ∼250 ms. The increase in the negative component was independent of the type of visual stimulus. These results suggest that interest toward content information is reflected in early-stage event-related brain potential responses.

  17. Investigation of He–W interactions using DiMES on DIII-D

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.

    Here, tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225–850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in themore » surface of W buttons after only a single DIII-D (3 s, ~150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04–0.1 MJ m –2.« less

  18. Investigation of He–W interactions using DiMES on DIII-D

    DOE PAGES

    Doerner, R. P.; Rudakov, D. L.; Chrobak, C. P.; ...

    2016-01-22

    Here, tungsten button samples were exposed to He ELMing H-mode plasma in DIII-D using 2.3 MW of electron cyclotron heating power. Prior to the exposures, the W buttons were exposed to either He, or D, plasma in PISCES-A for 2000 s at surface temperatures of 225–850 °C to create a variety of surfaces (surface blisters, subsurface nano-bubbles, fuzz). Erosion was spectroscopically measured from each DiMES sample, with the exception of the fuzzy W samples which showed almost undetectable WI emission. Post-exposure grazing incidence small angle x-ray scattering surface analysis showed the formation of 1.5 nm diameter He bubbles in themore » surface of W buttons after only a single DIII-D (3 s, ~150 ELMs) discharge, similar to the bubble layer resulting from the 2000 s. exposure in PISCES-A. No surface roughening, or damage, was detected on the samples after approximately 600 ELMs with energy density between 0.04–0.1 MJ m –2.« less

  19. What Orthopaedic Operating Room Surfaces Are Contaminated With Bioburden? A Study Using the ATP Bioluminescence Assay.

    PubMed

    Richard, Raveesh Daniel; Bowen, Thomas R

    2017-07-01

    Contaminated operating room surfaces can increase the risk of orthopaedic infections, particularly after procedures in which hardware implantation and instrumentation are used. The question arises as to how surgeons can measure surface cleanliness to detect increased levels of bioburden. This study aims to highlight the utility of adenosine triphosphate (ATP) bioluminescence technology as a novel technique in detecting the degree of contamination within the sterile operating room environment. What orthopaedic operating room surfaces are contaminated with bioburden? When energy is required for cellular work, ATP breaks down into adenosine biphosphate (ADP) and phosphate (P) and in that process releases energy. This process is inherent to all living things and can be detected as light emission with the use of bioluminescence assays. On a given day, six different orthopaedic surgery operating rooms (two adult reconstruction, two trauma, two spine) were tested before surgery with an ATP bioluminescence assay kit. All of the cases were considered clean surgery without infection, and this included the previously performed cases in each sampled room. These rooms had been cleaned and prepped for surgery but the patients had not been physically brought into the room. A total of 13 different surfaces were sampled once in each room: the operating room (OR) preparation table (both pre- and postdraping), OR light handles, Bovie machine buttons, supply closet countertops, the inside of the Bair Hugger™ hose, Bair Hugger™ buttons, right side of the OR table headboard, tourniquet machine buttons, the Clark-socket attachment, and patient positioners used for total hip and spine positioning. The relative light units (RLUs) obtained from each sample were recorded and data were compiled and averaged for analysis. These values were compared with previously published ATP benchmark values of 250 to 500 RLUs to define cleanliness in both the hospital and restaurant industries. All surfaces had bioburden. The ATP RLUs (mean ± SD) are reported for each surface in ascending order: the OR preparation table (postdraping; 8.3 ± 3.4), inside the sterilized pan (9.2 ± 5.5), the inside of the Bair Hugger™ hose (212.5 ± 155.7), supply closet countertops (281.7 ± 236.7), OR light handles (647.8 ± 903.7), the OR preparation table (predraping; 1054 ± 387.5), the Clark-socket attachment (1135.7 ± 705.3), patient positioners used for total hip and spine positioning (1201.7 ± 1144.9), Bovie machine buttons (1264.5 ± 638.8), Bair Hugger™ buttons (1340.8 ± 1064.1), tourniquet machine buttons (1666.5 ± 2144.9), computer keyboard (1810.8 ± 929.6), and the right side of the OR table headboard (2539 ± 5635.8). ATP bioluminescence is a novel method to measure cleanliness within the orthopaedic OR and can help identify environmental trouble spots that can potentially lead to increased infection rates. Future studies correlating ATP bioluminescence findings with microbiology cultures could add to the clinical utility of this technology. Surfaces such as the undersurface of the OR table headboard, Bair Hugger™ buttons, and tourniquet machine buttons should be routinely cleansed as part of an institutional protocol. Although correlation between ATP bioluminescence and clinical infection was not evaluated in this study, it is the subject of future research. Specifically, evaluating microbiology samples taken from these environmental surfaces and correlating them with increased bioburden found with ATP bioluminescence technology can help promote improved surgical cleaning practices.

  20. Strabismus and the Oculomotor System: Insights from Macaque Models

    PubMed Central

    Das, Vallabh E.

    2017-01-01

    Disrupting binocular vision in infancy leads to strabismus and oftentimes to a variety of associated visual sensory deficits and oculomotor abnormalities. Investigation of this disorder has been aided by the development of various animal models, each of which has advantages and disadvantages. In comparison to studies of binocular visual responses in cortical structures, investigations of neural oculomotor structures that mediate the misalignment and abnormalities of eye movements have been more recent, and these studies have shown that different brain areas are intimately involved in driving several aspects of the strabismic condition, including horizontal misalignment, dissociated deviations, A and V patterns of strabismus, disconjugate eye movements, nystagmus, and fixation switch. The responses of cells in visual and oculomotor areas that potentially drive the sensory deficits and also eye alignment and eye movement abnormalities follow a general theme of disrupted calibration, lower sensitivity, and poorer specificity compared with the normally developed visual oculomotor system. PMID:28532347

  1. Accurate guide wire of lag screw placement in the intertrochanteric fractures: a technical note.

    PubMed

    Li, Jiang; Wang, Liao; Li, Xiaodong; Feng, Kai; Tang, Jian; Wang, Xiaoqing

    2017-09-01

    Cephalomedullary fixations are commonly used in the treatment of intertrochanteric fractures. In clinical practice, one of the difficulties is when we exit the guide wire in a wrong position of femoral neck and insert near the hole again, the guide wire often flow into the previous track. This study develops a surgical technique to direct the guide wire to slip away the previous track and slip into a right position. When guide wire is exited to the cortex of femoral, we let the wire in and out at the cortical layer for several times to enlarge the entry hole. After that, electric drill is inverted, rubbed and entered slowly at a right angle. When guide wire encountered new resistance, the electric drill is turned back instantly. This technique can help trauma and orthopedic surgeons to obtain precision placement of the lag screw after the first try is failed.

  2. Automatic multiple-sample applicator and electrophoresis apparatus

    NASA Technical Reports Server (NTRS)

    Grunbaum, B. W. (Inventor)

    1977-01-01

    An apparatus for performing electrophoresis and a multiple-sample applicator is described. Electrophoresis is a physical process in which electrically charged molecules and colloidal particles, upon the application of a dc current, migrate along a gel or a membrane that is wetted with an electrolyte. A multiple-sample applicator is provided which coacts with a novel tank cover to permit an operator either to depress a single button, thus causing multiple samples to be deposited on the gel or on the membrane simultaneously, or to depress one or more sample applicators separately by means of a separate button for each applicator.

  3. Assessment of pediatric Malone antegrade continence enema (MACE) complications: Effects of variations in technique.

    PubMed

    Saikaly, Sami K; Rich, Mark A; Swana, Hubert S

    2016-08-01

    The Malone antegrade continence enema (MACE) procedure is performed for patients with fecal incontinence and constipation who do not respond to medical therapy. The MACE procedure provides antegrade catheter access to the right colon and allows administration of enemas to help evacuate the bowel regularly. The objective of this study was to identify risk factors for surgical complications in children who undergo the MACE procedure. Records from 97 pediatric patients who underwent MACE procedure were reviewed retrospectively. Data collected included age, sex, weight (obese/not obese), stomal location, presence of a permanent button/catheter in the stoma, open vs. laparoscopic surgery, and etiology of fecal incontinence/constipation. The complications reviewed included stomal stenosis, leakage, and stomal site infection. The relationships between the independent variables and complications were assessed using chi-square tests and Fisher's exact test. Statistical significance was set at p < 0.05. Overall, 66 (68%) patients had at least one complication. Twenty-three (23.7%) patients developed stomal stenosis, and 27 (27.8%) patients had significant stomal leakage. Insertion of a stomal button/catheter device was associated with an increased risk of developing stomal leakage and stomal infection. The presence of a stomal button/catheter was also associated with a decreased risk of stomal stenosis (Figure). The non-intubated, imbricated sub-population, preteen patients (<12 years old) experienced more stomal leakage than teenage patients. In this subgroup, patients with umbilical stomas also experienced more leakage than patients with right lower quadrant (RLQ) stomas. The prevalence rates of stomal complications in our study were consistent with previously reported series. In our study, however, stomal leakage had a higher prevalence in comparison with stomal stenosis. This seems to be related to the heterogeneity of the study group, which contained two variants of the MACE procedure; non-imbricated, intubated MACE and imbricated, non-intubated MACE. The use of stomal buttons in conjunction with MACE has previously been reported without changes in complication rates. We found the use of stomal buttons/catheters to be associated with changes in the prevalence of stomal complications. Stomal complications are common in the MACE procedure. The use of a permanent stomal button/catheter is associated with changes in the rates of stomal complications. While many find an umbilical stomal site is more cosmetically appealing, there is an increased risk of leakage with imbricated, non-intubated stomas. In the non-intubated, imbricated sub-population, the MACE procedure results in a higher risk of stomal leakage in preteen patients in comparison with teenage patients. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  4. Spatiotopic updating of visual feature information.

    PubMed

    Zimmermann, Eckart; Weidner, Ralph; Fink, Gereon R

    2017-10-01

    Saccades shift the retina with high-speed motion. In order to compensate for the sudden displacement, the visuomotor system needs to combine saccade-related information and visual metrics. Many neurons in oculomotor but also in visual areas shift their receptive field shortly before the execution of a saccade (Duhamel, Colby, & Goldberg, 1992; Nakamura & Colby, 2002). These shifts supposedly enable the binding of information from before and after the saccade. It is a matter of current debate whether these shifts are merely location based (i.e., involve remapping of abstract spatial coordinates) or also comprise information about visual features. We have recently presented fMRI evidence for a feature-based remapping mechanism in visual areas V3, V4, and VO (Zimmermann, Weidner, Abdollahi, & Fink, 2016). In particular, we found fMRI adaptation in cortical regions representing a stimulus' retinotopic as well as its spatiotopic position. Here, we asked whether spatiotopic adaptation exists independently from retinotopic adaptation and which type of information is behaviorally more relevant after saccade execution. We first adapted at the saccade target location only and found a spatiotopic tilt aftereffect. Then, we simultaneously adapted both the fixation and the saccade target location but with opposite tilt orientations. As a result, adaptation from the fixation location was carried retinotopically to the saccade target position. The opposite tilt orientation at the retinotopic location altered the effects induced by spatiotopic adaptation. More precisely, it cancelled out spatiotopic adaptation at the saccade target location. We conclude that retinotopic and spatiotopic visual adaptation are independent effects.

  5. Magnetoencephalographic responses to illusory figures: early evoked gamma is affected by processing of stimulus features.

    PubMed

    Herrmann, C S; Mecklinger, A

    2000-12-01

    We examined evoked and induced responses in event-related fields and gamma activity in the magnetoencephalogram (MEG) during a visual classification task. The objective was to investigate the effects of target classification and the different levels of discrimination between certain stimulus features. We performed two experiments, which differed only in the subjects' task while the stimuli were identical. In Experiment 1, subjects responded by a button-press to rare Kanizsa squares (targets) among Kanizsa triangles and non-Kanizsa figures (standards). This task requires the processing of both stimulus features (colinearity and number of inducer disks). In Experiment 2, the four stimuli of Experiment 1 were used as standards and the occurrence of an additional stimulus without any feature overlap with the Kanizsa stimuli (a rare and highly salient red fixation cross) had to be detected. Discrimination of colinearity and number of inducer disks was not necessarily required for task performance. We applied a wavelet-based time-frequency analysis to the data and calculated topographical maps of the 40 Hz activity. The early evoked gamma activity (100-200 ms) in Experiment 1 was higher for targets as compared to standards. In Experiment 2, no significant differences were found in the gamma responses to the Kanizsa figures and non-Kanizsa figures. This pattern of results suggests that early evoked gamma activity in response to visual stimuli is affected by the targetness of a stimulus and the need to discriminate between the features of a stimulus.

  6. Details of the Collagen and Elastin Architecture in the Human Limbal Conjunctiva, Tenon's Capsule and Sclera Revealed by Two-Photon Excited Fluorescence Microscopy.

    PubMed

    Park, Choul Yong; Marando, Catherine M; Liao, Jason A; Lee, Jimmy K; Kwon, Jiwon; Chuck, Roy S

    2016-10-01

    To investigate the architecture and distribution of collagen and elastin in human limbal conjunctiva, Tenon's capsule, and sclera. The limbal conjunctiva, Tenon's capsule, and sclera of human donor corneal buttons were imaged with an inverted two-photon excited fluorescence microscope. No fixation process was necessary. The laser (Ti:sapphire) was tuned at 850 nm for two-photon excitation. Backscatter signals of second harmonic generation (SHG) and autofluorescence (AF) were collected through a 425/30-nm and a 525/45-nm emission filter, respectively. Multiple, consecutive, and overlapping (z-stack) images were acquired. Collagen signals were collected with SHG, whereas elastin signals were collected with AF. The size and density of collagen bundles varied widely depending on depth: increasing from conjunctiva to sclera. In superficial image planes, collagen bundles were <10 μm in width, in a loose, disorganized arrangement. In deeper image planes (episclera and superficial sclera), collagen bundles were thicker (near 100 μm in width) and densely packed. Comparatively, elastin fibers were thinner and sparse. The orientation of elastin fibers was independent of collagen fibers in superficial layers; but in deep sclera, elastin fibers wove through collagen interbundle gaps. At the limbus, both collagen and elastin fibers were relatively compact and were distributed perpendicular to the limbal annulus. Two-photon excited fluorescence microscopy has enabled us to understand in greater detail the collagen and elastin architecture of the human limbal conjunctiva, Tenon's capsule, and sclera.

  7. Unconscious Evaluation of Faces on Social Dimensions

    PubMed Central

    Stewart, Lorna H.; Ajina, Sara; Getov, Spas; Bahrami, Bahador; Todorov, Alexander; Rees, Geraint

    2012-01-01

    It has been proposed that two major axes, dominance and trustworthiness, characterize the social dimensions of face evaluation. Whether evaluation of faces on these social dimensions is restricted to conscious appraisal or happens at a preconscious level is unknown. Here we provide behavioral evidence that such preconscious evaluations exist and that they are likely to be interpretations arising from interactions between the face stimuli and observer-specific traits. Monocularly viewed faces that varied independently along two social dimensions of trust and dominance were rendered invisible by continuous flash suppression (CFS) when a flashing pattern was presented to the other eye. Participants pressed a button as soon as they saw the face emerge from suppression to indicate whether the previously hidden face was located slightly to the left or right of central fixation. Dominant and untrustworthy faces took significantly longer time to emerge (T2E) compared with neutral faces. A control experiment showed these findings could not reflect delayed motor responses to conscious faces. Finally, we showed that participants' self-reported propensity to trust was strongly predictive of untrust avoidance (i.e., difference in T2E for untrustworthy vs neutral faces) as well as dominance avoidance (i.e., difference in T2E for dominant vs neutral faces). Dominance avoidance was also correlated with submissive behavior. We suggest that such prolongation of suppression for threatening faces may result from a passive fear response, leading to slowed visual perception. PMID:22468670

  8. Unconscious evaluation of faces on social dimensions.

    PubMed

    Stewart, Lorna H; Ajina, Sara; Getov, Spas; Bahrami, Bahador; Todorov, Alexander; Rees, Geraint

    2012-11-01

    It has been proposed that two major axes, dominance and trustworthiness, characterize the social dimensions of face evaluation. Whether evaluation of faces on these social dimensions is restricted to conscious appraisal or happens at a preconscious level is unknown. Here we provide behavioral evidence that such preconscious evaluations exist and that they are likely to be interpretations arising from interactions between the face stimuli and observer-specific traits. Monocularly viewed faces that varied independently along two social dimensions of trust and dominance were rendered invisible by continuous flash suppression (CFS) when a flashing pattern was presented to the other eye. Participants pressed a button as soon as they saw the face emerge from suppression to indicate whether the previously hidden face was located slightly to the left or right of central fixation. Dominant and untrustworthy faces took significantly longer time to emerge (T2E) compared with neutral faces. A control experiment showed these findings could not reflect delayed motor responses to conscious faces. Finally, we showed that participants' self-reported propensity to trust was strongly predictive of untrust avoidance (i.e., difference in T2E for untrustworthy vs neutral faces) as well as dominance avoidance (i.e., difference in T2E for dominant vs neutral faces). Dominance avoidance was also correlated with submissive behavior. We suggest that such prolongation of suppression for threatening faces may result from a passive fear response, leading to slowed visual perception. (PsycINFO Database Record (c) 2012 APA, all rights reserved).

  9. Influence of Button mushroom (Agaricus bisporus) on quality and refrigerated storage stability of patties prepared from sutchi catfish (Pangasius hypophthalmus).

    PubMed

    Nayak, Prakash Chandra; Raju, C V; Lakshmisha, I P; Singh, Rajkumar Ratankumar; Sofi, Faisal Rashid

    2015-06-01

    The ability of button mushroom (Agaricus bisporus) in changing physical, chemical, microbial and sensory properties of fish patties prepared from sutchi catfish (Pangasius hypophthalmus) was investigated. Two batches of fresh patties were prepared, one batch was treated with 15 % button mushroom (TP) and other batch was a control (CP) without mushroom. The patties were packed in polythene bags and stored under refrigerated condition (6 ± 2 ºC) without adding any preservatives for the estimation of storage stability. The analyses of patties were conducted at regular intervals of 3 days. The results showed that, Peroxide value, Thiobarbituric acid value, Free fatty acids increased significantly in CP at the end of 12 days whereas the TP was within the acceptable limit up to 16 days. Total volatile base nitrogen and Trimethylamine nitrogen also showed a similar trend. The Total plate count and Aerobic spore formers showed an increasing trend in CP when compared to TP. The sensory scores showed that the overall acceptability of CP were lower than TP, which was acceptable even after 16 days of storage. The present study showed that, the quality and storage stability of TP were observed to be in good condition up to 16 days and started deteriorating 20th day onwards, whereas the CP were acceptable only up to 12 days. Therefore it can be recommended that, addition of 15 % of button mushroom to sutchi catfish patty not only increases the nutritional quality but also increases the shelf life of patties under refrigerated storage.

  10. What Kind of Capsule Endoscope Is Suitable for a Controllable Self-Propelling Capsule Endoscope? Experimental Study Using a Porcine Stomach Model for Clinical Application (with Videos)

    PubMed Central

    Ota, Kazuhiro; Nouda, Sadaharu; Takeuchi, Toshihisa; Iguchi, Munetaka; Kojima, Yuichi; Kuramoto, Takanori; Inoue, Takuya; Shindo, Yasunori; Uesugi, Kenshiro; Fujito, Yoshiaki; Nishihara, Hironori; Ohtsuka, Naotake; Higuchi, Kazuhide

    2015-01-01

    Background We have been developing the Self-Propelling Capsule Endoscope (SPCE) that allows for controllability from outside of the body and real-time observation. What kind of capsule endoscope (CE) is suitable for a controllable SPCE is unclear and a very critical point for clinical application. We compared observing ability of three kinds of SPCEs with different viewing angles and frame rates. Methods Eleven buttons were sewed in an excised porcine stomach. Four examiners controlled the SPCE using PillCamSB2, -ESO2, and -COLON2 (Given Imaging Ltd., Israel), for 10 minutes each with the aim of detecting as many buttons and examining them as closely as possible. The ability to find lesions was assessed based on the number of detected buttons. The SPCE-performance score (SPS) was used to evaluate the ability to examine the lesions in detail. Results The SPCE-ESO2, -COLON2, and -SB2 detected 11 [interquartile range (IQR): 0], 10.5 (IQR, 0.5), and 8 (IQR, 1.0) buttons, respectively. The SPCE-ESO2 and -COLON2 had a significantly better ability to detect lesions than the -SB2 (p < 0.05). The SPCE-ESO2, -COLON2, and -SB2 had significantly different SPS values of 22 (IQR, 0), 16.5 (IQR, 1.5), and 14 (IQR, 1.0), respectively (p < 0.05 for all comparisons; SPCE-SB2 vs. -ESO2, -SB2 vs. -COLON2, and -ESO2 vs. -COLON2). Conclusions PillCamESO2 is most suitable in different three CEs for SPCE for examining lesions in detail of the stomach. PMID:26447694

  11. Limb-kinetic apraxia affects activities of daily living in Parkinson’s disease: a multi-center study

    PubMed Central

    Foki, T.; Vanbellingen, T.; Lungu, C.; Pirker, W.; Bohlhalter, S.; Nyffeler, T.; Kraemmer, J.; Haubenberger, D.; Fischmeister, F. Ph. S.; Auff, E.; Hallett, M.; Beisteiner, R.

    2017-01-01

    Background and purpose Impaired dexterity (fine hand movements) is often present in Parkinson’s disease (PD), even at early to moderate disease stages. It has a detrimental impact on activities of daily living (ADL) such as buttoning, contributing to reduced quality of life. Limb-kinetic apraxia, a loss of the ability to make precise, independent but coordinated finger and hand movements, may contribute to impaired dexterity even more than bradykinesia per se. However, the impact of limb-kinetic apraxia on ADL remains controversial. Our aim was to identify the strongest predictor of buttoning and unbuttoning in PD. It was hypothesized that coin rotation (a surrogate of limb-kinetic apraxia) represents the most important determinant. Methods Sixty-four right-handed, early to moderate PD patients were recruited from three movement disorder centers (Hoehn and Yahr stages 1–3). Buttoning, unbuttoning and coin rotation (right and left hand) represented the target tasks. Motor impairment was assessed according to the Unified Parkinson’s Disease Rating Scale. Results Multiple linear regression analysis showed that coin rotation with the right hand was the only significant predictor of buttoning (P < 0.001) and unbuttoning (P = 0.002). Notably, measures of bradykinesia or overall motor impairment did not represent significant predictors. Conclusions Constituting the novel key finding, limb-kinetic apraxia seems to be particularly relevant for ADL requiring dexterity skills in PD, even at early to moderate disease stages. Our results prompt research into the pathophysiological background and therapeutic options to treat limb-kinetic apraxia. The simple coin rotation test provides valuable information about ADL-related dexterity skills. PMID:27132653

  12. What Kind of Capsule Endoscope Is Suitable for a Controllable Self-Propelling Capsule Endoscope? Experimental Study Using a Porcine Stomach Model for Clinical Application (with Videos).

    PubMed

    Ota, Kazuhiro; Nouda, Sadaharu; Takeuchi, Toshihisa; Iguchi, Munetaka; Kojima, Yuichi; Kuramoto, Takanori; Inoue, Takuya; Shindo, Yasunori; Uesugi, Kenshiro; Fujito, Yoshiaki; Nishihara, Hironori; Ohtsuka, Naotake; Higuchi, Kazuhide

    2015-01-01

    We have been developing the Self-Propelling Capsule Endoscope (SPCE) that allows for controllability from outside of the body and real-time observation. What kind of capsule endoscope (CE) is suitable for a controllable SPCE is unclear and a very critical point for clinical application. We compared observing ability of three kinds of SPCEs with different viewing angles and frame rates. Eleven buttons were sewed in an excised porcine stomach. Four examiners controlled the SPCE using PillCamSB2, -ESO2, and -COLON2 (Given Imaging Ltd., Israel), for 10 minutes each with the aim of detecting as many buttons and examining them as closely as possible. The ability to find lesions was assessed based on the number of detected buttons. The SPCE-performance score (SPS) was used to evaluate the ability to examine the lesions in detail. The SPCE-ESO2, -COLON2, and -SB2 detected 11 [interquartile range (IQR): 0], 10.5 (IQR, 0.5), and 8 (IQR, 1.0) buttons, respectively. The SPCE-ESO2 and -COLON2 had a significantly better ability to detect lesions than the -SB2 (p < 0.05). The SPCE-ESO2, -COLON2, and -SB2 had significantly different SPS values of 22 (IQR, 0), 16.5 (IQR, 1.5), and 14 (IQR, 1.0), respectively (p < 0.05 for all comparisons; SPCE-SB2 vs. -ESO2, -SB2 vs. -COLON2, and -ESO2 vs. -COLON2). PillCamESO2 is most suitable in different three CEs for SPCE for examining lesions in detail of the stomach.

  13. Meal Microstructure Characterization from Sensor-Based Food Intake Detection.

    PubMed

    Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A; Higgins, Janine A; Sazonov, Edward

    2017-01-01

    To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1-30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button ( p -value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10-30s ( p -value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary.

  14. Meal Microstructure Characterization from Sensor-Based Food Intake Detection

    PubMed Central

    Doulah, Abul; Farooq, Muhammad; Yang, Xin; Parton, Jason; McCrory, Megan A.; Higgins, Janine A.; Sazonov, Edward

    2017-01-01

    To avoid the pitfalls of self-reported dietary intake, wearable sensors can be used. Many food ingestion sensors offer the ability to automatically detect food intake using time resolutions that range from 23 ms to 8 min. There is no defined standard time resolution to accurately measure ingestive behavior or a meal microstructure. This paper aims to estimate the time resolution needed to accurately represent the microstructure of meals such as duration of eating episode, the duration of actual ingestion, and number of eating events. Twelve participants wore the automatic ingestion monitor (AIM) and kept a standard diet diary to report their food intake in free-living conditions for 24 h. As a reference, participants were also asked to mark food intake with a push button sampled every 0.1 s. The duration of eating episodes, duration of ingestion, and number of eating events were computed from the food diary, AIM, and the push button resampled at different time resolutions (0.1–30s). ANOVA and multiple comparison tests showed that the duration of eating episodes estimated from the diary differed significantly from that estimated by the AIM and the push button (p-value <0.001). There were no significant differences in the number of eating events for push button resolutions of 0.1, 1, and 5 s, but there were significant differences in resolutions of 10–30s (p-value <0.05). The results suggest that the desired time resolution of sensor-based food intake detection should be ≤5 s to accurately detect meal microstructure. Furthermore, the AIM provides more accurate measurement of the eating episode duration than the diet diary. PMID:28770206

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fu, Wenkai; Ghosh, Priyarshini; Harrison, Mark

    The performance of traditional Hornyak buttons and two proposed variants for fast-neutron hodoscope applications was evaluated using Geant4. The Hornyak button is a ZnS(Ag)-based device previously deployed at the Idaho National Laboratory's TRansient REActor Test Facility (better known as TREAT) for monitoring fast neutrons emitted during pulsing of fissile fuel samples. Past use of these devices relied on pulse-shape discrimination to reduce the significant levels of background Cherenkov radiation. Proposed are two simple designs that reduce the overall light guide mass (here, polymethyl methacrylate or PMMA), employ silicon photomultipliers (SiPMs), and can be operated using pulse-height discrimination alone to eliminatemore » background noise to acceptable levels. Geant4 was first used to model a traditional Hornyak button, and for assumed, hodoscope-like conditions, an intrinsic efficiency of 0.35% for mono-directional fission neutrons was predicted. The predicted efficiency is in reasonably good agreement with experimental data from the literature and, hence, served to validate the physics models and approximations employed. Geant4 models were then developed to optimize the materials and geometries of two alternatives to the Hornyak button, one based on a homogeneous mixture of ZnS(Ag) and PMMA, and one based on alternating layers of ZnS(Ag) and PMMA oriented perpendicular to the incident neutron beam. For the same radiation environment, optimized, 5-cm long (along the beam path) devices of the homogeneous and layered designs were predicted to have efficiencies of approximately 1.3% and 3.3%, respectively. For longer devices, i.e., lengths larger than 25 cm, these efficiencies were shown to peak at approximately 2.2% and 5.9%, respectively. Furthermore, both designs were shown to discriminate Cherenkov noise intrinsically by using an appropriate pulse-height discriminator level, i.e., pulse-shape discrimination is not needed for these devices.« less

  16. Recognition and reading aloud of kana and kanji word: an fMRI study.

    PubMed

    Ino, Tadashi; Nakai, Ryusuke; Azuma, Takashi; Kimura, Toru; Fukuyama, Hidenao

    2009-03-16

    It has been proposed that different brain regions are recruited for processing two Japanese writing systems, namely, kanji (morphograms) and kana (syllabograms). However, this difference may depend upon what type of word was used and also on what type of task was performed. Using fMRI, we investigated brain activation for processing kanji and kana words with similar high familiarity in two tasks: word recognition and reading aloud. During both tasks, words and non-words were presented side by side, and the subjects were required to press a button corresponding to the real word in the word recognition task and were required to read aloud the real word in the reading aloud task. Brain activations were similar between kanji and kana during reading aloud task, whereas during word recognition task in which accurate identification and selection were required, kanji relative to kana activated regions of bilateral frontal, parietal and occipitotemporal cortices, all of which were related mainly to visual word-form analysis and visuospatial attention. Concerning the difference of brain activity between two tasks, differential activation was found only in the regions associated with task-specific sensorimotor processing for kana, whereas visuospatial attention network also showed greater activation during word recognition task than during reading aloud task for kanji. We conclude that the differences in brain activation between kanji and kana depend on the interaction between the script characteristics and the task demands.

  17. Similar Cerebral Motor Plans for Real and Virtual Actions

    PubMed Central

    Bozzacchi, Chiara; Giusti, Maria Assunta; Pitzalis, Sabrina; Spinelli, Donatella; Di Russo, Francesco

    2012-01-01

    A simple movement, such as pressing a button, can acquire different meanings by producing different consequences, such as starting an elevator or switching a TV channel. We evaluated whether the brain activity preceding a simple action is modulated by the expected consequences of the action itself. To further this aim, the motor-related cortical potentials were compared during two key-press actions that were identical from the kinematics point of view but different in both meaning and consequences. In one case (virtual grasp), the key-press started a video clip showing a hand moving toward a cup and grasping it; in the other case, the key-press did not produce any consequence (key-press). A third condition (real grasp) was also compared, in which subjects actually grasped the cup, producing the same action presented in the video clip. Data were collected from fifteen subjects. The results showed that motor preparation for virtual grasp (starting 3 s before the movement onset) was different from that of the key-press and similar to the real grasp preparation–as if subjects had to grasp the cup in person. In particular, both virtual and real grasp presented a posterior parietal negativity preceding activity in motor and pre-motor areas. In summary, this finding supports the hypothesis that motor preparation is affected by the meaning of the action, even when the action is only virtual. PMID:23112847

  18. METEOSAT studies of clouds and radiation budget

    NASA Technical Reports Server (NTRS)

    Saunders, R. W.

    1982-01-01

    Radiation budget studies of the atmosphere/surface system from Meteosat, cloud parameter determination from space, and sea surface temperature measurements from TIROS N data are all described. This work was carried out on the interactive planetary image processing system (IPIPS), which allows interactive manipulationion of the image data in addition to the conventional computational tasks. The current hardware configuration of IPIPS is shown. The I(2)S is the principal interactive display allowing interaction via a trackball, four buttons under program control, or a touch tablet. Simple image processing operations such as contrast enhancing, pseudocoloring, histogram equalization, and multispectral combinations, can all be executed at the push of a button.

  19. 20 mm lithium button battery causing an oesophageal perforation in a toddler: lessons in diagnosis and treatment.

    PubMed

    Soccorso, Giampiero; Grossman, Ole; Martinelli, Massimo; Marven, Sean S; Patel, Kirtik; Thomson, Mike; Roberts, Julian P

    2012-08-01

    Swallowed button batteries (BB) which remain lodged in the oesophagus are at risk of serious complications, particularly in young children. The authors report a 3-year-old child, who rapidly developed an oesophageal perforation, following the ingestion of a 20-mm lithium BB which was initially mistaken for a coin. A thoracotomy and T-tube management of the perforation led to a positive outcome. BBs (20 mm) in children should be removed quickly and close observation is required as the damage initiated by the battery can lead to a significant injury within a few hours.

  20. Hiroshima neutron fluence on a glass button from near ground zero.

    PubMed

    Fleischer, R L; Fujita, S; Hoshi, M

    2001-12-01

    A decorative glass button that was uncovered at a location that is 190 +/- 15 m from directly beneath the atomic explosion at Hiroshima on 6 August 1945 has been scanned for induced fission tracks produced mostly by the thermal neutrons from the bomb due to interactions with the trace uranium that is normally present in silicate glasses. In surveying 4.14 cm2 at 500x magnification, 28 tracks were seen. From a calibration irradiation in a nuclear reactor we infer that the neutron fluence in 1945 was 5.7(+/-1.1) x 10(11) cm(-2); and, allowing for shielding by the structure in which the button was probably located, the free-air (i.e., outside) value is estimated as 1.5(+/-0.5) x 10(12) cm(-2). A limit has been placed on possible fading of the radiation-damage tracks that could increase the fluence by at most a factor of 1.27. The values bracket the calculated value of 9 x 10(11) given in DS86 but are higher than the 3.6 x 10(11) inferred from induced radionuclides for the distance given. The difference is, however, within the observed variability of the two types of results.

Top