Sample records for cost effective electronics

  1. A quality-based cost model for new electronic systems and products

    NASA Astrophysics Data System (ADS)

    Shina, Sammy G.; Saigal, Anil

    1998-04-01

    This article outlines a method for developing a quality-based cost model for the design of new electronic systems and products. The model incorporates a methodology for determining a cost-effective design margin allocation for electronic products and systems and its impact on manufacturing quality and cost. A spreadsheet-based cost estimating tool was developed to help implement this methodology in order for the system design engineers to quickly estimate the effect of design decisions and tradeoffs on the quality and cost of new products. The tool was developed with automatic spreadsheet connectivity to current process capability and with provisions to consider the impact of capital equipment and tooling purchases to reduce the product cost.

  2. Radiation Challenges for Electronics in the Vision for Space Exploration

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.

    2006-01-01

    The slides present a brief snapshot discussing electronics and exploration-related challenges. Radiation effects have been the prime target, however, electronic parts reliability issues must also be considered. Modern electronics are designed with a 3-5 year lifetime. Upscreening does not improve reliability, merely determines inherent levels. Testing costs are driven by device complexity; they increase tester complexity, beam requirements, and facility choices. Commercial devices may improve performance, but are not cost panaceas. There is need for a more cost-effective access to high energy heavy ion facilities such as NSCL and NSRL. Costs for capable test equipment can run more than $1M for full testing.

  3. Cost effectiveness of a medical digital library.

    PubMed

    Roussel, F; Darmoni, S J; Thirion, B

    2001-01-01

    The rapid increase in the price of electronic journals has made the optimization of collection management an urgent task. As there is currently no standard procedure for the evaluation of this problem, we applied the Reading Factor (RF), an electronically computed indicator used for consultation of individual articles. The aim of our study was to assess the cost effective impact of modifications in our digital library (i.e. change of access from the Intranet to the Internet or change in editorial policy). The digital OVID library at Rouen University Hospital continues to be cost-effective in comparison with the interlibrary loan costs. Moreover, when electronic versions are offered alongside a limited amount of interlibrary loans, a reduction in library costs was observed.

  4. A systematic review of the cost and cost-effectiveness of electronic discharge communications

    PubMed Central

    Sevick, Laura K; Esmail, Rosmin; Tang, Karen; Lorenzetti, Diane L; Ronksley, Paul; James, Matthew; Santana, Maria; Ghali, William A; Clement, Fiona

    2017-01-01

    Background The transition between acute care and community care can be a vulnerable period in a patients’ treatment due to the potential for postdischarge adverse events. The vulnerability of this period has been attributed to factors related to the miscommunication between hospital-based and community-based physicians. Electronic discharge communication has been proposed as one solution to bridge this communication gap. Prior to widespread implementation of these tools, the costs and benefits should be considered. Objective To establish the cost and cost-effectiveness of electronic discharge communications compared with traditional discharge systems for individuals who have completed care with one provider and are transitioning care to a new provider. Methods We conducted a systematic review of the published literature, using best practices, to identify economic evaluations/cost analyses of electronic discharge communication tools. Inclusion criteria were: (1) economic analysis and (2) electronic discharge communication tool as the intervention. Quality of each article was assessed, and data were summarised using a component-based analysis. Results One thousand unique abstracts were identified, and 57 full-text articles were assessed for eligibility. Four studies met final inclusion criteria. These studies varied in their primary objectives, methodology, costs reported and outcomes. All of the studies were of low to good quality. Three of the studies reported a cost-effectiveness measure ranging from an incremental daily cost of decreasing average discharge note completion by 1 day of $0.331 (2003 Canadian), a cost per page per discharge letter of €9.51 and a dynamic net present value of €31.1 million for a 5-year implementation of the intervention. None of the identified studies considered clinically meaningful patient or quality outcomes. Discussion Economic analyses of electronic discharge communications are scarcely reported, and with inconsistent methodology and outcomes. Further studies are needed to understand the cost-effectiveness and value for patient care. PMID:28674136

  5. Printed electronic on flexible and glass substrates

    NASA Astrophysics Data System (ADS)

    Futera, Konrad; Jakubowska, Małgorzata; Kozioł, Grażyna

    2010-09-01

    Organic electronics is a platform technology that enables multiple applications based on organic electronics but varied in specifications. Organic electronics is based on the combination of new materials and cost-effective, large area production processes that provide new fields of application. Organic electronic by its size, weight, flexibility and environmental friendliness electronics enables low cost production of numerous electrical components and provides for such promising fields of application as: intelligent packaging, low cost RFID, flexible solar cells, disposable diagnostic devices or games, and printed batteries [1]. The paper presents results of inkjetted electronics elements on flexible and glass substrates. The investigations was target on characterizing shape, surface and geometry of printed structures. Variety of substrates were investigated, within some, low cost, non specialized substrate, design for other purposes than organic electronic.

  6. Cost-utility and cost-effectiveness studies of telemedicine, electronic, and mobile health systems in the literature: a systematic review.

    PubMed

    de la Torre-Díez, Isabel; López-Coronado, Miguel; Vaca, Cesar; Aguado, Jesús Saez; de Castro, Carlos

    2015-02-01

    A systematic review of cost-utility and cost-effectiveness research works of telemedicine, electronic health (e-health), and mobile health (m-health) systems in the literature is presented. Academic databases and systems such as PubMed, Scopus, ISI Web of Science, and IEEE Xplore were searched, using different combinations of terms such as "cost-utility" OR "cost utility" AND "telemedicine," "cost-effectiveness" OR "cost effectiveness" AND "mobile health," etc. In the articles searched, there were no limitations in the publication date. The search identified 35 relevant works. Many of the articles were reviews of different studies. Seventy-nine percent concerned the cost-effectiveness of telemedicine systems in different specialties such as teleophthalmology, telecardiology, teledermatology, etc. More articles were found between 2000 and 2013. Cost-utility studies were done only for telemedicine systems. There are few cost-utility and cost-effectiveness studies for e-health and m-health systems in the literature. Some cost-effectiveness studies demonstrate that telemedicine can reduce the costs, but not all. Among the main limitations of the economic evaluations of telemedicine systems are the lack of randomized control trials, small sample sizes, and the absence of quality data and appropriate measures.

  7. A systematic review of the cost and cost-effectiveness of electronic discharge communications.

    PubMed

    Sevick, Laura K; Esmail, Rosmin; Tang, Karen; Lorenzetti, Diane L; Ronksley, Paul; James, Matthew; Santana, Maria; Ghali, William A; Clement, Fiona

    2017-07-02

    The transition between acute care and community care can be a vulnerable period in a patients' treatment due to the potential for postdischarge adverse events. The vulnerability of this period has been attributed to factors related to the miscommunication between hospital-based and community-based physicians. Electronic discharge communication has been proposed as one solution to bridge this communication gap. Prior to widespread implementation of these tools, the costs and benefits should be considered. To establish the cost and cost-effectiveness of electronic discharge communications compared with traditional discharge systems for individuals who have completed care with one provider and are transitioning care to a new provider. We conducted a systematic review of the published literature, using best practices, to identify economic evaluations/cost analyses of electronic discharge communication tools. Inclusion criteria were: (1) economic analysis and (2) electronic discharge communication tool as the intervention. Quality of each article was assessed, and data were summarised using a component-based analysis. One thousand unique abstracts were identified, and 57 full-text articles were assessed for eligibility. Four studies met final inclusion criteria. These studies varied in their primary objectives, methodology, costs reported and outcomes. All of the studies were of low to good quality. Three of the studies reported a cost-effectiveness measure ranging from an incremental daily cost of decreasing average discharge note completion by 1 day of $0.331 (2003 Canadian), a cost per page per discharge letter of €9.51 and a dynamic net present value of €31.1 million for a 5-year implementation of the intervention. None of the identified studies considered clinically meaningful patient or quality outcomes. Economic analyses of electronic discharge communications are scarcely reported, and with inconsistent methodology and outcomes. Further studies are needed to understand the cost-effectiveness and value for patient care. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  8. Effectiveness and cost-effectiveness of computer and other electronic aids for smoking cessation: a systematic review and network meta-analysis.

    PubMed

    Chen, Y-F; Madan, J; Welton, N; Yahaya, I; Aveyard, P; Bauld, L; Wang, D; Fry-Smith, A; Munafò, M R

    2012-01-01

    Smoking is harmful to health. On average, lifelong smokers lose 10 years of life, and about half of all lifelong smokers have their lives shortened by smoking. Stopping smoking reverses or prevents many of these harms. However, cessation services in the NHS achieve variable success rates with smokers who want to quit. Approaches to behaviour change can be supplemented with electronic aids, and this may significantly increase quit rates and prevent a proportion of cases that relapse. The primary research question we sought to answer was: What is the effectiveness and cost-effectiveness of internet, pc and other electronic aids to help people stop smoking? We addressed the following three questions: (1) What is the effectiveness of internet sites, computer programs, mobile telephone text messages and other electronic aids for smoking cessation and/or reducing relapse? (2) What is the cost-effectiveness of incorporating internet sites, computer programs, mobile telephone text messages and other electronic aids into current nhs smoking cessation programmes? and (3) What are the current gaps in research into the effectiveness of internet sites, computer programs, mobile telephone text messages and other electronic aids to help people stop smoking? For the effectiveness review, relevant primary studies were sought from The Cochrane Library [Cochrane Central Register of Controlled Trials (CENTRAL)] 2009, Issue 4, and MEDLINE (Ovid), EMBASE (Ovid), PsycINFO (Ovid), Health Management Information Consortium (HMIC) (Ovid) and Cumulative Index to Nursing and Allied Health Literature (CINAHL) (EBSCOhost) from 1980 to December 2009. In addition, NHS Economic Evaluation Database (NHS EED) and Database of Abstracts of Reviews of Effects (DARE) were searched for information on cost-effectiveness and modelling for the same period. Reference lists of included studies and of relevant systematic reviews were examined to identify further potentially relevant studies. Research registries of ongoing studies including National Institute for Health Research (NIHR) Clinical Research Network Portfolio Database, Current Controlled Trials and ClinicalTrials.gov were also searched, and further information was sought from contacts with experts. Randomised controlled trials (RCTs) and quasi-RCTs evaluating smoking cessation programmes that utilise computer, internet, mobile telephone or other electronic aids in adult smokers were included in the effectiveness review. Relevant studies of other design were included in the cost-effectiveness review and supplementary review. Pair-wise meta-analyses using both random- and fixed-effects models were carried out. Bayesian mixed-treatment comparisons (MTCs) were also performed. A de novo decision-analytical model was constructed for estimating the cost-effectiveness of interventions. Expected value of perfect information (EVPI) was calculated. Narrative synthesis of key themes and issues that may influence the acceptability and usability of electronic aids was provided in the supplementary review. This effectiveness review included 60 RCTs/quasi-RCTs reported in 77 publications. Pooled estimate for prolonged abstinence [relative risk (RR) = 1.32, 95% confidence interval (CI) 1.21 to 1.45] and point prevalence abstinence (RR = 1.14, 95% CI 1.07 to 1.22) suggested that computer and other electronic aids increase the likelihood of cessation compared with no intervention or generic self-help materials. There was no significant difference in effect sizes between aid to cessation studies (which provide support to smokers who are ready to quit) and cessation induction studies (which attempt to encourage a cessation attempt in smokers who are not yet ready to quit). Results from MTC also showed small but significant intervention effect (time to relapse, mean hazard ratio 0.87, 95% credible interval 0.83 to 0.92). Cost-threshold analyses indicated some form of electronic intervention is likely to be cost-effective when added to non-electronic behavioural support, but there is substantial uncertainty with regard to what the most effective (thus most cost-effective) type of electronic intervention is, which warrants further research. EVPI calculations suggested the upper limit for the benefit of this research is around £ 2000-3000 per person. The review focuses on smoking cessation programmes in the adult population, but does not cover smoking cessation in adolescents. Most available evidence relates to interventions with a single tailored component, while evidence for different modes of delivery (e.g. e-mail, text messaging) is limited. Therefore, the findings of lack of sufficient evidence for proving or refuting effectiveness should not be regarded as evidence of ineffectiveness. We have examined only a small number of factors that could potentially influence the effectiveness of the interventions. A comprehensive evaluation of potential effect modifiers at study level in a systematic review of complex interventions remains challenging. Information presented in published papers is often insufficient to allow accurate coding of each intervention or comparator. A limitation of the cost-effectiveness analysis, shared with several previous cost-effectiveness analyses of smoking cessation interventions, is that intervention benefit is restricted to the first quit attempt. Exploring the impact of interventions on subsequent attempts requires more detailed information on patient event histories than is available from current evidence. Our effectiveness review concluded that computer and other electronic aids increase the likelihood of cessation compared with no intervention or generic self-help materials, but the effect is small. The effectiveness does not appear to vary with respect to mode of delivery and concurrent non-electronic co-interventions. Our cost-effectiveness review suggests that making some form of electronic support available to smokers actively seeking to quit is highly likely to be cost-effective. This is true whether the electronic intervention is delivered alongside brief advice or more intensive counselling. The key source of uncertainty is that around the comparative effectiveness of different types of electronic interventions. Our review suggests that further research is needed on the relative benefits of different forms of delivery for electronic aids, the content of delivery, and the acceptability of these technologies for smoking cessation with subpopulations of smokers, particularly disadvantaged groups. More evidence is also required on the relationship between involving users in the design of interventions and the impact this has on effectiveness, and finally on how electronic aids developed and tested in research settings are applied in routine practice and in the community.

  9. The impact of clinical trial design on cost-effectiveness analyses: illustration from a published study of the one-touch ultrasmart blood glucose meter for insulin-using diabetes patients.

    PubMed

    Tunis, Sandra L; Minshall, Michael E

    2008-06-01

    One source of variation in cost-effectiveness analyses stems from the characteristics of the study upon which each is based. This report provides cost-effectiveness analyses using data from a recently published randomized clinical trial (RCT) comparing an integrated glucose meter/electronic logbook to a conventional glucose meter/paper logbook in helping to control hemoglobin A1c in type 1 or type 2 diabetes. RCT participants and health care professionals (HCPs) were "blinded" to results of meter downloads until week 16, when participants chose systems. They returned to "usual care" and could obtain meter results and share them with their HCPs. Those eligible returned 26-65 weeks later for an observational visit. The CORE Diabetes Model was used to estimate the 60-year cost-effectiveness of the electronic (vs. conventional) meter. With no price premium, the newer technology represented a dominant strategy (greater effectiveness/lower costs) based on the RCT alone or on the RCT + observational visit. With a $100.00/year premium, the incremental cost-effectiveness ratio was $28,053 based on the RCT, but the electronic monitor was dominant when simulations included observational visit results. One plausible reason for the greater benefits of the electronic monitor with the observational period included was the ability of patients and HCPs to make better clinical and lifestyle modifications based on fully available, formatted data. Because the advantages of the electronic meter are based on timely access to accurate feedback, the importance of naturalistic, unblinded studies for technology assessments can be appreciated. Addressing the methodological issues discussed here can help integrate clinical and economic outcomes for diabetes care innovations.

  10. Cost-Utility and Cost-Effectiveness Studies of Telemedicine, Electronic, and Mobile Health Systems in the Literature: A Systematic Review

    PubMed Central

    López-Coronado, Miguel; Vaca, Cesar; Aguado, Jesús Saez; de Castro, Carlos

    2015-01-01

    Abstract Objective: A systematic review of cost-utility and cost-effectiveness research works of telemedicine, electronic health (e-health), and mobile health (m-health) systems in the literature is presented. Materials and Methods: Academic databases and systems such as PubMed, Scopus, ISI Web of Science, and IEEE Xplore were searched, using different combinations of terms such as “cost-utility” OR “cost utility” AND “telemedicine,” “cost-effectiveness” OR “cost effectiveness” AND “mobile health,” etc. In the articles searched, there were no limitations in the publication date. Results: The search identified 35 relevant works. Many of the articles were reviews of different studies. Seventy-nine percent concerned the cost-effectiveness of telemedicine systems in different specialties such as teleophthalmology, telecardiology, teledermatology, etc. More articles were found between 2000 and 2013. Cost-utility studies were done only for telemedicine systems. Conclusions: There are few cost-utility and cost-effectiveness studies for e-health and m-health systems in the literature. Some cost-effectiveness studies demonstrate that telemedicine can reduce the costs, but not all. Among the main limitations of the economic evaluations of telemedicine systems are the lack of randomized control trials, small sample sizes, and the absence of quality data and appropriate measures. PMID:25474190

  11. The cost of doing business: cost structure of electronic immunization registries.

    PubMed

    Fontanesi, John M; Flesher, Don S; De Guire, Michelle; Lieberthal, Allan; Holcomb, Kathy

    2002-10-01

    To predict the true cost of developing and maintaining an electronic immunization registry, and to set the framework for developing future cost-effective and cost-benefit analysis. Primary data collected at three immunization registries located in California, accounting for 90 percent of all immunization records in registries in the state during the study period. A parametric cost analysis compared registry development and maintenance expenditures to registry performance requirements. Data were collected at each registry through interviews, reviews of expenditure records, technical accomplishments development schedules, and immunization coverage rates. The cost of building immunization registries is predictable and independent of the hardware/software combination employed. The effort requires four man-years of technical effort or approximately $250,000 in 1998 dollars. Costs for maintaining a registry were approximately $5,100 per end user per three-year period. There is a predictable cost structure for both developing and maintaining immunization registries. The cost structure can be used as a framework for examining the cost-effectiveness and cost-benefits of registries. The greatest factor effecting improvement in coverage rates was ongoing, user-based administrative investment.

  12. A mixed methods protocol to evaluate the effect and cost-effectiveness of an Integrated electronic Diagnosis Approach (IeDA) for the management of childhood illnesses at primary health facilities in Burkina Faso.

    PubMed

    Blanchet, Karl; Lewis, James J; Pozo-Martin, Francisco; Satouro, Arsene; Somda, Serge; Ilboudo, Patrick; Sarrassat, Sophie; Cousens, Simon

    2016-08-04

    Burkina Faso introduced the Integrated Management of Childhood Illnesses (IMCI) strategy in 2003. However, an evaluation conducted in 2013 found that only 28 % of children were assessed for three danger signs as recommended by IMCI, and only 15 % of children were correctly classified. About 30 % of children were correctly prescribed with an antibiotic for suspected pneumonia or oral rehydration salts (ORS) for diarrhoea, and 40 % were correctly referred. Recent advances in information and communication technologies (ICT) and use of electronic clinical protocols hold the potential to transform healthcare delivery in low-income countries. However, no evidence is available on the effect of ICT on adherence to IMCI. This paper describes the research protocol of a mixed methods study that aims to measure the effect of the Integrated electronic Diagnosis Approach innovation (an electronic IMCI protocol provided to nurses) in two regions of Burkina Faso. The study combines a stepped-wedge trial, a realistic evaluation and an economic study in order to capture the effect of the innovation after its introduction on the level of adherence, cost and acceptability. The main challenge is to interconnect the three substudies. In integrating outcome, process and cost data, we focus on three key questions: (i) How does the effectiveness and the cost of the intervention vary by type of health worker and type of health centre? (ii) What is the impact of changes in the content, coverage and quality of the IeDA intervention on adherence and cost-effectiveness? (iii) What mechanisms of change (including costs) might explain the relationship between the IeDA intervention and adherence? Clinicaltrials.gov, NCT02341469 .

  13. The Cost of Doing Business: Cost Structure of Electronic Immunization Registries

    PubMed Central

    Fontanesi, John M; Flesher, Don S; De Guire, Michelle; Lieberthal, Allan; Holcomb, Kathy

    2002-01-01

    Objective To predict the true cost of developing and maintaining an electronic immunization registry, and to set the framework for developing future cost-effective and cost-benefit analysis. Data Sources/Study Setting Primary data collected at three immunization registries located in California, accounting for 90 percent of all immunization records in registries in the state during the study period. Study Design A parametric cost analysis compared registry development and maintenance expenditures to registry performance requirements. Data Collection/Extraction Methods Data were collected at each registry through interviews, reviews of expenditure records, technical accomplishments development schedules, and immunization coverage rates. Principal Findings The cost of building immunization registries is predictable and independent of the hardware/software combination employed. The effort requires four man-years of technical effort or approximately $250,000 in 1998 dollars. Costs for maintaining a registry were approximately $5,100 per end user per three-year period. Conclusions There is a predictable cost structure for both developing and maintaining immunization registries. The cost structure can be used as a framework for examining the cost-effectiveness and cost-benefits of registries. The greatest factor effecting improvement in coverage rates was ongoing, user-based administrative investment. PMID:12479497

  14. Dealing with electronic waste: modeling the costs and environmental benefits of computer monitor disposal.

    PubMed

    Macauley, Molly; Palmer, Karen; Shih, Jhih-Shyang

    2003-05-01

    The importance of information technology to the world economy has brought about a surge in demand for electronic equipment. With rapid technological change, a growing fraction of the increasing stock of many types of electronics becomes obsolete each year. We model the costs and benefits of policies to manage 'e-waste' by focusing on a large component of the electronic waste stream-computer monitors-and the environmental concerns associated with disposal of the lead embodied in cathode ray tubes (CRTs) used in most monitors. We find that the benefits of avoiding health effects associated with CRT disposal appear far outweighed by the costs for a wide range of policies. For the stock of monitors disposed of in the United States in 1998, we find that policies restricting or banning some popular disposal options would increase disposal costs from about US dollar 1 per monitor to between US dollars 3 and US dollars 20 per monitor. Policies to promote a modest amount of recycling of monitor parts, including lead, can be less expensive. In all cases, however, the costs of the policies exceed the value of the avoided health effects of CRT disposal.

  15. Improving BP control through electronic communications: an economic evaluation.

    PubMed

    Fishman, Paul A; Cook, Andrea J; Anderson, Melissa L; Ralston, James D; Catz, Sheryl L; Carrell, David; Carlson, James; Green, Beverly B

    2013-09-01

    Web-based collaborative approaches to managing chronic illness show promise for both improving health outcomes and increasing the efficiency of the healthcare system. Analyze the cost-effectiveness of the Electronic Communications and Home Blood Pressure Monitoring to Improve Blood Pressure Control (e-BP) study, a randomized controlled trial that used a patient-shared electronic medical record, home blood pressure (BP) monitoring, and web-based pharmacist care to improve BP control (<140/90 mm Hg). Incremental cost-effectiveness analysis conducted from a health plan perspective. Cost-effectiveness of home BP monitoring and web-based pharmacist care estimated for percent change in patients with controlled BP and cost per mm Hg in diastolic and systolic BP relative to usual care and home BP monitoring alone. A 1% improvement in number of patients with controlled BP using home BP monitoring and web-based pharmacist care-the e-BP program-costs $16.65 (95% confidence interval: 15.37- 17.94) relative to home BP monitoring and web training alone. Each mm HG reduction in systolic and diastolic BP achieved through the e-BP program costs $65.29 (59.91-70.67) relativeto home BP monitoring and web tools only. Life expectancy was increased at an incremental cost of $1850 (1635-2064) and $2220 (1745-2694) per year of life saved for men and women, respectively. Web-based collaborative care can be used to achieve BP control at a relatively low cost. Future research should examine the cost impact of potential long-term clinical improvements.

  16. Cost-effectiveness of an electronic clinical decision support system for improving quality of antenatal and childbirth care in rural Tanzania: an intervention study.

    PubMed

    Saronga, Happiness Pius; Duysburgh, Els; Massawe, Siriel; Dalaba, Maxwell Ayindenaba; Wangwe, Peter; Sukums, Felix; Leshabari, Melkizedeck; Blank, Antje; Sauerborn, Rainer; Loukanova, Svetla

    2017-08-07

    QUALMAT project aimed at improving quality of maternal and newborn care in selected health care facilities in three African countries. An electronic clinical decision support system was implemented to support providers comply with established standards in antenatal and childbirth care. Given that health care resources are limited and interventions differ in their potential impact on health and costs (efficiency), this study aimed at assessing cost-effectiveness of the system in Tanzania. This was a quantitative pre- and post- intervention study involving 6 health centres in rural Tanzania. Cost information was collected from health provider's perspective. Outcome information was collected through observation of the process of maternal care. Incremental cost-effectiveness ratios for antenatal and childbirth care were calculated with testing of four models where the system was compared to the conventional paper-based approach to care. One-way sensitivity analysis was conducted to determine whether changes in process quality score and cost would impact on cost-effectiveness ratios. Economic cost of implementation was 167,318 USD, equivalent to 27,886 USD per health center and 43 USD per contact. The system improved antenatal process quality by 4.5% and childbirth care process quality by 23.3% however these improvements were not statistically significant. Base-case incremental cost-effectiveness ratios of the system were 2469 USD and 338 USD per 1% change in process quality for antenatal and childbirth care respectively. Cost-effectiveness of the system was sensitive to assumptions made on costs and outcomes. Although the system managed to marginally improve individual process quality variables, it did not have significant improvement effect on the overall process quality of care in the short-term. A longer duration of usage of the electronic clinical decision support system and retention of staff are critical to the efficiency of the system and can reduce the invested resources. Realization of gains from the system requires effective implementation and an enabling healthcare system. Registered clinical trial at www.clinicaltrials.gov ( NCT01409824 ). Registered May 2009.

  17. Is There Evidence of Cost Benefits of Electronic Medical Records, Standards, or Interoperability in Hospital Information Systems? Overview of Systematic Reviews

    PubMed Central

    2017-01-01

    Background Electronic health (eHealth) interventions may improve the quality of care by providing timely, accessible information about one patient or an entire population. Electronic patient care information forms the nucleus of computerized health information systems. However, interoperability among systems depends on the adoption of information standards. Additionally, investing in technology systems requires cost-effectiveness studies to ensure the sustainability of processes for stakeholders. Objective The objective of this study was to assess cost-effectiveness of the use of electronically available inpatient data systems, health information exchange, or standards to support interoperability among systems. Methods An overview of systematic reviews was conducted, assessing the MEDLINE, Cochrane Library, LILACS, and IEEE Library databases to identify relevant studies published through February 2016. The search was supplemented by citations from the selected papers. The primary outcome sought the cost-effectiveness, and the secondary outcome was the impact on quality of care. Independent reviewers selected studies, and disagreement was resolved by consensus. The quality of the included studies was evaluated using a measurement tool to assess systematic reviews (AMSTAR). Results The primary search identified 286 papers, and two papers were manually included. A total of 211 were systematic reviews. From the 20 studies that were selected after screening the title and abstract, 14 were deemed ineligible, and six met the inclusion criteria. The interventions did not show a measurable effect on cost-effectiveness. Despite the limited number of studies, the heterogeneity of electronic systems reported, and the types of intervention in hospital routines, it was possible to identify some preliminary benefits in quality of care. Hospital information systems, along with information sharing, had the potential to improve clinical practice by reducing staff errors or incidents, improving automated harm detection, monitoring infections more effectively, and enhancing the continuity of care during physician handoffs. Conclusions This review identified some benefits in the quality of care but did not provide evidence that the implementation of eHealth interventions had a measurable impact on cost-effectiveness in hospital settings. However, further evidence is needed to infer the impact of standards adoption or interoperability in cost benefits of health care; this in turn requires further research. PMID:28851681

  18. Is There Evidence of Cost Benefits of Electronic Medical Records, Standards, or Interoperability in Hospital Information Systems? Overview of Systematic Reviews.

    PubMed

    Reis, Zilma Silveira Nogueira; Maia, Thais Abreu; Marcolino, Milena Soriano; Becerra-Posada, Francisco; Novillo-Ortiz, David; Ribeiro, Antonio Luiz Pinho

    2017-08-29

    Electronic health (eHealth) interventions may improve the quality of care by providing timely, accessible information about one patient or an entire population. Electronic patient care information forms the nucleus of computerized health information systems. However, interoperability among systems depends on the adoption of information standards. Additionally, investing in technology systems requires cost-effectiveness studies to ensure the sustainability of processes for stakeholders. The objective of this study was to assess cost-effectiveness of the use of electronically available inpatient data systems, health information exchange, or standards to support interoperability among systems. An overview of systematic reviews was conducted, assessing the MEDLINE, Cochrane Library, LILACS, and IEEE Library databases to identify relevant studies published through February 2016. The search was supplemented by citations from the selected papers. The primary outcome sought the cost-effectiveness, and the secondary outcome was the impact on quality of care. Independent reviewers selected studies, and disagreement was resolved by consensus. The quality of the included studies was evaluated using a measurement tool to assess systematic reviews (AMSTAR). The primary search identified 286 papers, and two papers were manually included. A total of 211 were systematic reviews. From the 20 studies that were selected after screening the title and abstract, 14 were deemed ineligible, and six met the inclusion criteria. The interventions did not show a measurable effect on cost-effectiveness. Despite the limited number of studies, the heterogeneity of electronic systems reported, and the types of intervention in hospital routines, it was possible to identify some preliminary benefits in quality of care. Hospital information systems, along with information sharing, had the potential to improve clinical practice by reducing staff errors or incidents, improving automated harm detection, monitoring infections more effectively, and enhancing the continuity of care during physician handoffs. This review identified some benefits in the quality of care but did not provide evidence that the implementation of eHealth interventions had a measurable impact on cost-effectiveness in hospital settings. However, further evidence is needed to infer the impact of standards adoption or interoperability in cost benefits of health care; this in turn requires further research. ©Zilma Silveira Nogueira Reis, Thais Abreu Maia, Milena Soriano Marcolino, Francisco Becerra-Posada, David Novillo-Ortiz, Antonio Luiz Pinho Ribeiro. Originally published in JMIR Medical Informatics (http://medinform.jmir.org), 29.08.2017.

  19. Portable electronic vision enhancement systems in comparison with optical magnifiers for near vision activities: an economic evaluation alongside a randomized crossover trial.

    PubMed

    Bray, Nathan; Brand, Andrew; Taylor, John; Hoare, Zoe; Dickinson, Christine; Edwards, Rhiannon T

    2017-08-01

    To determine the incremental cost-effectiveness of portable electronic vision enhancement system (p-EVES) devices compared with optical low vision aids (LVAs), for improving near vision visual function, quality of life and well-being of people with a visual impairment. An AB/BA randomized crossover trial design was used. Eighty-two participants completed the study. Participants were current users of optical LVAs who had not tried a p-EVES device before and had a stable visual impairment. The trial intervention was the addition of a p-EVES device to the participant's existing optical LVA(s) for 2 months, and the control intervention was optical LVA use only, for 2 months. Cost-effectiveness and cost-utility analyses were conducted from a societal perspective. The mean cost of the p-EVES intervention was £448. Carer costs were £30 (4.46 hr) less for the p-EVES intervention compared with the LVA only control. The mean difference in total costs was £417. Bootstrapping gave an incremental cost-effectiveness ratio (ICER) of £736 (95% CI £481 to £1525) for a 7% improvement in near vision visual function. Cost per quality-adjusted life year (QALY) ranged from £56 991 (lower 95% CI = £19 801) to £66 490 (lower 95% CI = £23 055). Sensitivity analysis varying the commercial price of the p-EVES device reduced ICERs by up to 75%, with cost per QALYs falling below £30 000. Portable electronic vision enhancement system (p-EVES) devices are likely to be a cost-effective use of healthcare resources for improving near vision visual function, but this does not translate into cost-effective improvements in quality of life, capability or well-being. © 2016 The Authors. Acta Ophthalmologica published by John Wiley & Sons Ltd on behalf of Acta Ophthalmologica Scandinavica Foundation and European Association for Vision & Eye Research.

  20. Simple and cost-effective method of highly conductive and elastic carbon nanotube/polydimethylsiloxane composite for wearable electronics.

    PubMed

    Kim, Jeong Hun; Hwang, Ji-Young; Hwang, Ha Ryeon; Kim, Han Seop; Lee, Joong Hoon; Seo, Jae-Won; Shin, Ueon Sang; Lee, Sang-Hoon

    2018-01-22

    The development of various flexible and stretchable materials has attracted interest for promising applications in biomedical engineering and electronics industries. This interest in wearable electronics, stretchable circuits, and flexible displays has created a demand for stable, easily manufactured, and cheap materials. However, the construction of flexible and elastic electronics, on which commercial electronic components can be mounted through simple and cost-effective processing, remains challenging. We have developed a nanocomposite of carbon nanotubes (CNTs) and polydimethylsiloxane (PDMS) elastomer. To achieve uniform distributions of CNTs within the polymer, an optimized dispersion process was developed using isopropyl alcohol (IPA) and methyl-terminated PDMS in combination with ultrasonication. After vaporizing the IPA, various shapes and sizes can be easily created with the nanocomposite, depending on the mold. The material provides high flexibility, elasticity, and electrical conductivity without requiring a sandwich structure. It is also biocompatible and mechanically stable, as demonstrated by cytotoxicity assays and cyclic strain tests (over 10,000 times). We demonstrate the potential for the healthcare field through strain sensor, flexible electric circuits, and biopotential measurements such as EEG, ECG, and EMG. This simple and cost-effective fabrication method for CNT/PDMS composites provides a promising process and material for various applications of wearable electronics.

  1. Thermal Management and Reliability of Automotive Power Electronics and Electric Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narumanchi, Sreekant V; Bennion, Kevin S; Cousineau, Justine E

    Low-cost, high-performance thermal management technologies are helping meet aggressive power density, specific power, cost, and reliability targets for power electronics and electric machines. The National Renewable Energy Laboratory is working closely with numerous industry and research partners to help influence development of components that meet aggressive performance and cost targets through development and characterization of cooling technologies, and thermal characterization and improvements of passive stack materials and interfaces. Thermomechanical reliability and lifetime estimation models are important enablers for industry in cost-and time-effective design.

  2. Cost-effectiveness of electronic training in domestic violence risk assessment: ODARA 101.

    PubMed

    Hilton, N Zoe; Ham, Elke

    2015-03-01

    The need for domestic violence training has increased with the development of evidence-based risk assessment tools, which must be scored correctly for valid application. Emerging research indicates that training in domestic violence risk assessment can increase scoring accuracy, but despite the increasing popularity of electronic training, it is not yet known whether it can be an effective method of risk assessment training. In the present study, 87 assessors from various professions had training in the Ontario Domestic Assault Risk Assessment either face-to-face or using an electronic training program. The two conditions were equally effective, as measured by performance on a post-training skill acquisition test. Completion rates were 100% for face-to-face and 86% for electronic training, an improvement over a previously evaluated manual-only condition. The estimated per-trainee cost of electronic training was one third that of face-to-face training and expected to decrease. More rigorous evaluations of electronic training for risk assessment are recommended. © The Author(s) 2014.

  3. HIPAA brings new requirements, new opportunities.

    PubMed

    Moynihan, J J; McLure, M L

    2000-03-01

    The passage of the Health Insurance Portability and Accountability Act of 1996 (HIPAA) brought with it the need for Federal rules to implement the act's simplification and cost-reduction efforts. HHS has published proposed rules related to security for the electronic transmission of health information, privacy of individually identifiable health information, transactions and code sets, and national provider and employer identifiers. Additional proposed rules will be published this year for claims attachments and health plan identifiers. Although HIPAA does not require providers to conduct business electronically, the new standards give providers the opportunity to reduce healthcare administrative costs significantly and undertake electronic commerce efficiently and cost-effectively.

  4. Interface and facet control during Czochralski growth of (111) InSb crystals for cost reduction and yield improvement of IR focal plane array substrates

    NASA Astrophysics Data System (ADS)

    Gray, Nathan W.; Perez-Rubio, Victor; Bolke, Joseph G.; Alexander, W. B.

    2014-10-01

    Focal plane arrays (FPAs) made on InSb wafers are the key cost-driving component in IR imaging systems. The electronic and crystallographic properties of the wafer directly determine the imaging device performance. The "facet effect" describes the non-uniform electronic properties of crystals resulting from anisotropic dopant segregation during bulk growth. When the segregation coefficient of dopant impurities changes notably across the melt/solid interface of a growing crystal the result is non-uniform electronic properties across wafers made from these crystals. The effect is more pronounced in InSb crystals grown on the (111) axis compared with other orientations and crystal systems. FPA devices made on these wafers suffer costly yield hits due to inconsistent device response and performance. Historically, InSb crystal growers have grown approximately 9-19 degree off-axis from the (111) to avoid the facet effect and produced wafers with improved uniformity of electronic properties. It has been shown by researchers in the 1960s that control of the facet effect can produce uniform small diameter crystals. In this paper, we share results employing a process that controls the facet effect when growing large diameter crystals from which 4, 5, and 6" wafers can be manufactured. The process change resulted in an increase in wafers yielded per crystal by several times, all with high crystal quality and uniform electronic properties. Since the crystals are grown on the (111) axis, manufacturing (111) oriented wafers is straightforward with standard semiconductor equipment and processes common to the high-volume silicon wafer industry. These benefits result in significant manufacturing cost savings and increased value to our customers.

  5. Sandia National Laboratories: Working with Sandia: Contract Audit

    Science.gov Websites

    Government Auditing Standards. Electronic Cost Claims Electronic Cost Claim (ECC) An Electronic Cost Claim is ) ECC-Cost Reimbursable Template and Instructions (MS Excel) ECC-University Template (MS Excel) ECC -Indirect Rates (Indirect Rate Cost Claim) (MS Excel) Electronic Cost Proposals Electronic Cost Proposal

  6. Support and Assessment for Fall Emergency Referrals (SAFER 1): Cluster Randomised Trial of Computerised Clinical Decision Support for Paramedics

    PubMed Central

    Snooks, Helen Anne; Carter, Ben; Dale, Jeremy; Foster, Theresa; Humphreys, Ioan; Logan, Philippa Anne; Lyons, Ronan Anthony; Mason, Suzanne Margaret; Phillips, Ceri James; Sanchez, Antonio; Wani, Mushtaq; Watkins, Alan; Wells, Bridget Elizabeth; Whitfield, Richard; Russell, Ian Trevor

    2014-01-01

    Objective To evaluate effectiveness, safety and cost-effectiveness of Computerised Clinical Decision Support (CCDS) for paramedics attending older people who fall. Design Cluster trial randomised by paramedic; modelling. Setting 13 ambulance stations in two UK emergency ambulance services. Participants 42 of 409 eligible paramedics, who attended 779 older patients for a reported fall. Interventions Intervention paramedics received CCDS on Tablet computers to guide patient care. Control paramedics provided care as usual. One service had already installed electronic data capture. Main Outcome Measures Effectiveness: patients referred to falls service, patient reported quality of life and satisfaction, processes of care. Safety Further emergency contacts or death within one month. Cost-Effectiveness Costs and quality of life. We used findings from published Community Falls Prevention Trial to model cost-effectiveness. Results 17 intervention paramedics used CCDS for 54 (12.4%) of 436 participants. They referred 42 (9.6%) to falls services, compared with 17 (5.0%) of 343 participants seen by 19 control paramedics [Odds ratio (OR) 2.04, 95% CI 1.12 to 3.72]. No adverse events were related to the intervention. Non-significant differences between groups included: subsequent emergency contacts (34.6% versus 29.1%; OR 1.27, 95% CI 0.93 to 1.72); quality of life (mean SF12 differences: MCS −0.74, 95% CI −2.83 to +1.28; PCS −0.13, 95% CI −1.65 to +1.39) and non-conveyance (42.0% versus 36.7%; OR 1.13, 95% CI 0.84 to 1.52). However ambulance job cycle time was 8.9 minutes longer for intervention patients (95% CI 2.3 to 15.3). Average net cost of implementing CCDS was £208 per patient with existing electronic data capture, and £308 without. Modelling estimated cost per quality-adjusted life-year at £15,000 with existing electronic data capture; and £22,200 without. Conclusions Intervention paramedics referred twice as many participants to falls services with no difference in safety. CCDS is potentially cost-effective, especially with existing electronic data capture. Trial Registration ISRCTN Register ISRCTN10538608 PMID:25216281

  7. NASAwide electronic publishing system: Electronic printing and duplicating, stage-2 evaluation report (GSFC)

    NASA Technical Reports Server (NTRS)

    Tuey, Richard C.; Lane, Robert; Hart, Susan V.

    1995-01-01

    The NASA Scientific and Technical Information Office was assigned the responsibility to continue with the expansion of the NASAwide networked electronic duplicating effort by including the Goddard Space Flight Center (GSFC) as an additional node to the existing configuration of networked electronic duplicating systems within NASA. The subject of this report is the evaluation of a networked electronic duplicating system which meets the duplicating requirements and expands electronic publishing capabilities without increasing current operating costs. This report continues the evaluation reported in 'NASA Electronic Publishing System - Electronic Printing and Duplicating Evaluation Report' (NASA TM-106242) and 'NASA Electronic Publishing System - Stage 1 Evaluation Report' (NASA TM-106510). This report differs from the previous reports through the inclusion of an external networked desktop editing, archival, and publishing functionality which did not exist with the previous networked electronic duplicating system. Additionally, a two-phase approach to the evaluation was undertaken; the first was a paper study justifying a 90-day, on-site evaluation, and the second phase was to validate, during the 90-day evaluation, the cost benefits and productivity increases that could be achieved in an operational mode. A benchmark of the functionality of the networked electronic publishing system and external networked desktop editing, archival, and publishing system was performed under a simulated daily production environment. This report can be used to guide others in determining the most cost effective duplicating/publishing alternative through the use of cost/benefit analysis and return on investment techniques. A treatise on the use of these techniques can be found by referring to 'NASA Electronic Publishing System -Cost/Benefit Methodology' (NASA TM-106662).

  8. NASA Electronic Publishing System: Cost/benefit Methodology

    NASA Technical Reports Server (NTRS)

    Tuey, Richard C.

    1994-01-01

    The NASA Scientific and Technical Information Office was assigned the responsibility to examine the benefits of the utilization of electronic printing and duplicating systems throughout NASA Installations and Headquarters. The subject of this report is the documentation of the methodology used in justifying the acquisition of the most cost beneficial solution for the printing and duplicating requirements of a duplicating facility that is contemplating the acquisition of an electronic printing and duplicating system. Four alternatives are presented with each alternative costed out with its associated benefits. The methodology goes a step further than just a cost benefit analysis through its comparison of risks associated with each alternative, sensitivity to number of impressions and productivity gains on the selected alternative and finally the return on investment for the selected alternative. The report can be used in conjunction with the two earlier reports, NASA-TM-106242 and TM-106510 in guiding others in determining the cost effective duplicating alternative.

  9. Automated and electronically assisted hand hygiene monitoring systems: a systematic review.

    PubMed

    Ward, Melissa A; Schweizer, Marin L; Polgreen, Philip M; Gupta, Kalpana; Reisinger, Heather S; Perencevich, Eli N

    2014-05-01

    Hand hygiene is one of the most effective ways to prevent transmission of health care-associated infections. Electronic systems and tools are being developed to enhance hand hygiene compliance monitoring. Our systematic review assesses the existing evidence surrounding the adoption and accuracy of automated systems or electronically enhanced direct observations and also reviews the effectiveness of such systems in health care settings. We systematically reviewed PubMed for articles published between January 1, 2000, and March 31, 2013, containing the terms hand AND hygiene or hand AND disinfection or handwashing. Resulting articles were reviewed to determine if an electronic system was used. We identified 42 articles for inclusion. Four types of systems were identified: electronically assisted/enhanced direct observation, video-monitored direct observation systems, electronic dispenser counters, and automated hand hygiene monitoring networks. Fewer than 20% of articles identified included calculations for efficiency or accuracy. Limited data are currently available to recommend adoption of specific automatic or electronically assisted hand hygiene surveillance systems. Future studies should be undertaken that assess the accuracy, effectiveness, and cost-effectiveness of such systems. Given the restricted clinical and infection prevention budgets of most facilities, cost-effectiveness analysis of specific systems will be required before these systems are widely adopted. Published by Mosby, Inc.

  10. Do surveys with paper and electronic devices differ in quality and cost? Experience from the Rufiji Health and demographic surveillance system in Tanzania.

    PubMed

    Mukasa, Oscar; Mushi, Hildegalda P; Maire, Nicolas; Ross, Amanda; de Savigny, Don

    2017-01-01

    Data entry at the point of collection using mobile electronic devices may make data-handling processes more efficient and cost-effective, but there is little literature to document and quantify gains, especially for longitudinal surveillance systems. To examine the potential of mobile electronic devices compared with paper-based tools in health data collection. Using data from 961 households from the Rufiji Household and Demographic Survey in Tanzania, the quality and costs of data collected on paper forms and electronic devices were compared. We also documented, using qualitative approaches, field workers, whom we called 'enumerators', and households' members on the use of both methods. Existing administrative records were combined with logistics expenditure measured directly from comparison households to approximate annual costs per 1,000 households surveyed. Errors were detected in 17% (166) of households for the paper records and 2% (15) for the electronic records (p < 0.001). There were differences in the types of errors (p = 0.03). Of the errors occurring, a higher proportion were due to accuracy in paper surveys (79%, 95% CI: 72%, 86%) compared with electronic surveys (58%, 95% CI: 29%, 87%). Errors in electronic surveys were more likely to be related to completeness (32%, 95% CI 12%, 56%) than in paper surveys (11%, 95% CI: 7%, 17%).The median duration of the interviews ('enumeration'), per household was 9.4 minutes (90% central range 6.4, 12.2) for paper and 8.3 (6.1, 12.0) for electronic surveys (p = 0.001). Surveys using electronic tools, compared with paper-based tools, were less costly by 28% for recurrent and 19% for total costs. Although there were technical problems with electronic devices, there was good acceptance of both methods by enumerators and members of the community. Our findings support the use of mobile electronic devices for large-scale longitudinal surveys in resource-limited settings.

  11. Cost-effectiveness analysis of a hospital electronic medication management system.

    PubMed

    Westbrook, Johanna I; Gospodarevskaya, Elena; Li, Ling; Richardson, Katrina L; Roffe, David; Heywood, Maureen; Day, Richard O; Graves, Nicholas

    2015-07-01

    To conduct a cost-effectiveness analysis of a hospital electronic medication management system (eMMS). We compared costs and benefits of paper-based prescribing with a commercial eMMS (CSC MedChart) on one cardiology ward in a major 326-bed teaching hospital, assuming a 15-year time horizon and a health system perspective. The eMMS implementation and operating costs were obtained from the study site. We used data on eMMS effectiveness in reducing potential adverse drug events (ADEs), and potential ADEs intercepted, based on review of 1 202 patient charts before (n = 801) and after (n = 401) eMMS. These were combined with published estimates of actual ADEs and their costs. The rate of potential ADEs following eMMS fell from 0.17 per admission to 0.05; a reduction of 71%. The annualized eMMS implementation, maintenance, and operating costs for the cardiology ward were A$61 741 (US$55 296). The estimated reduction in ADEs post eMMS was approximately 80 actual ADEs per year. The reduced costs associated with these ADEs were more than sufficient to offset the costs of the eMMS. Estimated savings resulting from eMMS implementation were A$63-66 (US$56-59) per admission (A$97 740-$102 000 per annum for this ward). Sensitivity analyses demonstrated results were robust when both eMMS effectiveness and costs of actual ADEs were varied substantially. The eMMS within this setting was more effective and less expensive than paper-based prescribing. Comparison with the few previous full economic evaluations available suggests a marked improvement in the cost-effectiveness of eMMS, largely driven by increased effectiveness of contemporary eMMs in reducing medication errors. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association.

  12. An Analytical Framework for Evaluating E-Commerce Business Models and Strategies.

    ERIC Educational Resources Information Center

    Lee, Chung-Shing

    2001-01-01

    Considers electronic commerce as a paradigm shift, or a disruptive innovation, and presents an analytical framework based on the theories of transaction costs and switching costs. Topics include business transformation process; scale effect; scope effect; new sources of revenue; and e-commerce value creation model and strategy. (LRW)

  13. 78 FR 13546 - Defense Federal Acquisition Regulation Supplement; Electronic Subcontracting Reporting System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... direct agencies to assess all costs and benefits of available regulatory alternatives and, if regulation... economic, environmental, public health and safety effects, distributive impacts, and equity). E.O. 13563 emphasizes the importance of quantifying both costs and benefits, of reducing costs, of harmonizing rules...

  14. Cost-benefit analysis of electronic medical record system at a tertiary care hospital.

    PubMed

    Choi, Jong Soo; Lee, Woo Baik; Rhee, Poong-Lyul

    2013-09-01

    Although Electronic Medical Record (EMR) systems provide various benefits, there are both advantages and disadvantages regarding its cost-effectiveness. This study analyzed the economic effects of EMR systems using a cost-benefit analysis based on the differential costs of managerial accounting. Samsung Medical Center (SMC) is a general hospital in Korea that developed an EMR system for outpatients from 2006 to 2008. This study measured the total costs and benefits during an 8-year period after EMR adoption. The costs include the system costs of building the EMR and the costs incurred in smoothing its adoption. The benefits included cost reductions after its adoption and additional revenues from both remodeling of paper-chart storage areas and medical transcriptionists' contribution. The measured amounts were discounted by SMC's expected interest rate to calculate the net present value (NPV), benefit-cost ratio (BCR), and discounted payback period (DPP). During the analysis period, the cumulative NPV and the BCR were US$3,617 thousand and 1.23, respectively. The DPP was about 6.18 years. Although the adoption of an EMR resulted in overall growth in administrative costs, it is cost-effective since the cumulative NPV was positive. The positive NPV was attributed to both cost reductions and additional revenues. EMR adoption is not so attractive to management in that the DPP is longer than 5 years at 6.18 and the BCR is near 1 at 1.23. However, an EMR is a worthwhile investment, seeing that this study did not include any qualitative benefits and that the paper-chart system was cost-centric.

  15. Cost-Effectiveness of a Clinical Childhood Obesity Intervention.

    PubMed

    Sharifi, Mona; Franz, Calvin; Horan, Christine M; Giles, Catherine M; Long, Michael W; Ward, Zachary J; Resch, Stephen C; Marshall, Richard; Gortmaker, Steven L; Taveras, Elsie M

    2017-11-01

    To estimate the cost-effectiveness and population impact of the national implementation of the Study of Technology to Accelerate Research (STAR) intervention for childhood obesity. In the STAR cluster-randomized trial, 6- to 12-year-old children with obesity seen at pediatric practices with electronic health record (EHR)-based decision support for primary care providers and self-guided behavior-change support for parents had significantly smaller increases in BMI than children who received usual care. We used a microsimulation model of a national implementation of STAR from 2015 to 2025 among all pediatric primary care providers in the United States with fully functional EHRs to estimate cost, impact on obesity prevalence, and cost-effectiveness. The expected population reach of a 10-year national implementation is ∼2 million children, with intervention costs of $119 per child and $237 per BMI unit reduced. At 10 years, assuming maintenance of effect, the intervention is expected to avert 43 000 cases and 226 000 life-years with obesity at a net cost of $4085 per case and $774 per life-year with obesity averted. Limiting implementation to large practices and using higher estimates of EHR adoption improved both cost-effectiveness and reach, whereas decreasing the maintenance of the intervention's effect worsened the former. A childhood obesity intervention with electronic decision support for clinicians and self-guided behavior-change support for parents may be more cost-effective than previous clinical interventions. Effective and efficient interventions that target children with obesity are necessary and could work in synergy with population-level prevention strategies to accelerate progress in reducing obesity prevalence. Copyright © 2017 by the American Academy of Pediatrics.

  16. Atmosphere to Electrons (A2e): Enabling the Wind Plant of Tomorrow

    ScienceCinema

    Zayas, Jose; Derby, Mike; Ralston, Kiersten; Clark, Charlton; Brake, Dan; Johnson, Nick

    2018-01-16

    Atmosphere to Electrons (A2e) is a multi-year U.S. Department of Energy (DOE) research initiative targeting significant reductions in the cost of wind energy through an improved understanding of the complex physics governing electricity generation by wind plants. The goal of A2e is to ensure future wind plants are sited, built, and operated in a way that produces the most cost-effective, usable electric power.

  17. Cost effectiveness of ergonomic redesign of electronic motherboard.

    PubMed

    Sen, Rabindra Nath; Yeow, Paul H P

    2003-09-01

    A case study to illustrate the cost effectiveness of ergonomic redesign of electronic motherboard was presented. The factory was running at a loss due to the high costs of rejects and poor quality and productivity. Subjective assessments and direct observations were made on the factory. Investigation revealed that due to motherboard design errors, the machine had difficulty in placing integrated circuits onto the pads, the operators had much difficulty in manual soldering certain components and much unproductive manual cleaning (MC) was required. Consequently, there were high rejects and occupational health and safety (OHS) problems, such as, boredom and work discomfort. Also, much labour and machine costs were spent on repairs. The motherboard was redesigned to correct the design errors, to allow more components to be machine soldered and to reduce MC. This eliminated rejects, reduced repairs, saved US dollars 581495/year and improved operators' OHS. The customer also saved US dollars 142105/year on loss of business.

  18. Electron-beam conditioning by thomson scattering.

    PubMed

    Schroeder, C B; Esarey, E; Leemans, W P

    2004-11-05

    A method is proposed for conditioning electron beams via Thomson scattering. The conditioning provides a quadratic correlation between the electron energy deviation and the betatron amplitude of the electrons, which results in enhanced gain in free-electron lasers. Quantum effects imply conditioning must occur at high laser fluence and moderate electron energy. Conditioning of x-ray free-electron lasers should be achievable with present laser technology, leading to significant size and cost reductions of these large-scale facilities.

  19. Cost-effectiveness analysis of a hospital electronic medication management system

    PubMed Central

    Gospodarevskaya, Elena; Li, Ling; Richardson, Katrina L; Roffe, David; Heywood, Maureen; Day, Richard O; Graves, Nicholas

    2015-01-01

    Objective To conduct a cost–effectiveness analysis of a hospital electronic medication management system (eMMS). Methods We compared costs and benefits of paper-based prescribing with a commercial eMMS (CSC MedChart) on one cardiology ward in a major 326-bed teaching hospital, assuming a 15-year time horizon and a health system perspective. The eMMS implementation and operating costs were obtained from the study site. We used data on eMMS effectiveness in reducing potential adverse drug events (ADEs), and potential ADEs intercepted, based on review of 1 202 patient charts before (n = 801) and after (n = 401) eMMS. These were combined with published estimates of actual ADEs and their costs. Results The rate of potential ADEs following eMMS fell from 0.17 per admission to 0.05; a reduction of 71%. The annualized eMMS implementation, maintenance, and operating costs for the cardiology ward were A$61 741 (US$55 296). The estimated reduction in ADEs post eMMS was approximately 80 actual ADEs per year. The reduced costs associated with these ADEs were more than sufficient to offset the costs of the eMMS. Estimated savings resulting from eMMS implementation were A$63–66 (US$56–59) per admission (A$97 740–$102 000 per annum for this ward). Sensitivity analyses demonstrated results were robust when both eMMS effectiveness and costs of actual ADEs were varied substantially. Conclusion The eMMS within this setting was more effective and less expensive than paper-based prescribing. Comparison with the few previous full economic evaluations available suggests a marked improvement in the cost–effectiveness of eMMS, largely driven by increased effectiveness of contemporary eMMs in reducing medication errors. PMID:25670756

  20. Flexible and low-voltage integrated circuits constructed from high-performance nanocrystal transistors.

    PubMed

    Kim, David K; Lai, Yuming; Diroll, Benjamin T; Murray, Christopher B; Kagan, Cherie R

    2012-01-01

    Colloidal semiconductor nanocrystals are emerging as a new class of solution-processable materials for low-cost, flexible, thin-film electronics. Although these colloidal inks have been shown to form single, thin-film field-effect transistors with impressive characteristics, the use of multiple high-performance nanocrystal field-effect transistors in large-area integrated circuits has not been shown. This is needed to understand and demonstrate the applicability of these discrete nanocrystal field-effect transistors for advanced electronic technologies. Here we report solution-deposited nanocrystal integrated circuits, showing nanocrystal integrated circuit inverters, amplifiers and ring oscillators, constructed from high-performance, low-voltage, low-hysteresis CdSe nanocrystal field-effect transistors with electron mobilities of up to 22 cm(2) V(-1) s(-1), current modulation >10(6) and subthreshold swing of 0.28 V dec(-1). We fabricated the nanocrystal field-effect transistors and nanocrystal integrated circuits from colloidal inks on flexible plastic substrates and scaled the devices to operate at low voltages. We demonstrate that colloidal nanocrystal field-effect transistors can be used as building blocks to construct complex integrated circuits, promising a viable material for low-cost, flexible, large-area electronics.

  1. 24 CFR 208.112 - Cost.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .../or software is not cost effective may contract out the electronic data transmission function to organizations that provide such services, including, but not limited to the following organizations: local management agents, local management associations and management agents with centralized facilities. Owners of...

  2. 77 FR 60689 - Transmission Planning and Cost Allocation by Transmission Owning and Operating Public Utilities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-04

    ... filings must be submitted in accordance with the Commission's electronic tariff filing (eTariff... eTariff Filing Title field and in the Description field in eFiling. DATES: Effective on October 4... electronic tariff filing (eTariff) requirements in Electronic Tariff Filings, Order No. 714, FERC Stats...

  3. Investigation of solar cells fabricated on low-cost silicon sheet materials using 1 MeV electron irradiation

    NASA Technical Reports Server (NTRS)

    Kachare, A. H.; Hyland, S. L.; Garlick, G. F. J.

    1981-01-01

    The use of high energy electron irradiation is investigated as a controlled means to study in more detail the junction depletion layer processes of solar cells made on various low-cost silicon sheet materials. Results show that solar cells made on Czochralski grown silicon exhibit enhancement of spectral response in the shorter wavelength region when irradiated with high energy electrons. The base region damage can be reduced by subsequent annealing at 450 C which restores the degraded longer wavelength response, although the shorter wavelength enhancement persists. The second diode component of the cell dark forward bias current is also reduced by electron irradiation, while thermal annealing at 450 C without electron irradiation can also produce these same effects. Electron irradiation produces small changes in the shorter wavelength spectral responses and junction improvements in solar cells made on WEB, EFG, and HEM silicon. It is concluded that these beneficial effects on cell characteristics are due to the reduction of oxygen associated deep level recombination centers in the N(+) diffused layer and in the junction.

  4. An Analysis of the Cost Effectiveness of Various Electronic Alternatives for Delivering Distance Education Compared to the Travel Costs for Live Instruction.

    ERIC Educational Resources Information Center

    Caffarella, Edward; And Others

    The feasibility and relative costs of four telecommunication systems for delivering university courses to distant locations in Colorado were compared. The four systems were compressed video, vertical blanking interval video, satellite video, and audiographic systems. Actual costs to install and operate each for a 5-year period were determined,…

  5. Cyber warfare and electronic warfare integration in the operational environment of the future: cyber electronic warfare

    NASA Astrophysics Data System (ADS)

    Askin, Osman; Irmak, Riza; Avsever, Mustafa

    2015-05-01

    For the states with advanced technology, effective use of electronic warfare and cyber warfare will be the main determining factor of winning a war in the future's operational environment. The developed states will be able to finalize the struggles they have entered with a minimum of human casualties and minimum cost thanks to high-tech. Considering the increasing number of world economic problems, the development of human rights and humanitarian law it is easy to understand the importance of minimum cost and minimum loss of human. In this paper, cyber warfare and electronic warfare concepts are examined in conjunction with the historical development and the relationship between them is explained. Finally, assessments were carried out about the use of cyber electronic warfare in the coming years.

  6. A Change of Course: The Importance to DoD of International Standards for Electronic Commerce

    DTIC Science & Technology

    1991-01-01

    The U.S. Department of Defense (DoD) is committed to using electronic commerce in the future with the over 300,000 vendors interested in doing...business with DoD. Electronic commerce will move DoD from a paper-based world to one based on electronic transactions enabled by the exchange of formatted...electronic messages referred to as electronic data interchange (EDI). With electronic commerce , DoD plans to reduce costs, increase effectiveness, and

  7. Cost-utility analysis of searching electronic health records and cascade testing to identify and diagnose familial hypercholesterolaemia in England and Wales.

    PubMed

    Crosland, Paul; Maconachie, Ross; Buckner, Sara; McGuire, Hugh; Humphries, Steve E; Qureshi, Nadeem

    2018-05-17

    The cost effectiveness of cascade testing for familial hypercholesterolaemia (FH) is well recognised. Less clear is the cost effectiveness of FH screening when it includes case identification strategies that incorporate routinely available data from primary and secondary care electronic health records. Nine strategies were compared, all using cascade testing in combination with different index case approaches (primary care identification, secondary care identification, and clinical assessment using the Simon Broome (SB) or Dutch Lipid Clinic Network (DLCN) criteria). A decision analytic model was informed by three systematic literature reviews and expert advice provided by a NICE Guideline Committee. The model found that the addition of primary care case identification by database search for patients with recorded total cholesterol >9.3 mmol/L was more cost effective than cascade testing alone. The incremental cost-effectiveness ratio (ICER) of clinical assessment using the DLCN criteria was £3254 per quality-adjusted life year (QALY) compared with case-finding with no genetic testing. The ICER of clinical assessment using the SB criteria was £13,365 per QALY (compared with primary care identification using the DLCN criteria), indicating that the SB criteria was preferred because it achieved additional health benefits at an acceptable cost. Secondary care identification, with either the SB or DLCN criteria, was not cost effective, alone (dominated and dominated respectively) or combined with primary care identification (£63, 514 per QALY, and £82,388 per QALY respectively). Searching primary care databases for people at high risk of FH followed by cascade testing is likely to be cost-effective. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. [Electronic versus paper-based patient records: a cost-benefit analysis].

    PubMed

    Neubauer, A S; Priglinger, S; Ehrt, O

    2001-11-01

    The aim of this study is to compare the costs and benefits of electronic, paperless patient records with the conventional paper-based charts. Costs and benefits of planned electronic patient records are calculated for a University eye hospital with 140 beds. Benefit is determined by direct costs saved by electronic records. In the example shown, the additional benefits of electronic patient records, as far as they can be quantified total 192,000 DM per year. The costs of the necessary investments are 234,000 DM per year when using a linear depreciation over 4 years. In total, there are additional annual costs for electronic patient records of 42,000 DM. Different scenarios were analyzed. By increasing the time of depreciation to 6 years, the cost deficit reduces to only approximately 9,000 DM. Increased wages reduce the deficit further while the deficit increases with a loss of functions of the electronic patient record. However, several benefits of electronic records regarding research, teaching, quality control and better data access cannot be easily quantified and would greatly increase the benefit to cost ratio. Only part of the advantages of electronic patient records can easily be quantified in terms of directly saved costs. The small cost deficit calculated in this example is overcompensated by several benefits, which can only be enumerated qualitatively due to problems in quantification.

  9. Modern developments for ground-based monitoring of fire behavior and effects

    Treesearch

    Colin C. Hardy; Robert Kremens; Matthew B. Dickinson

    2010-01-01

    Advances in electronic technology over the last several decades have been staggering. The cost of electronics continues to decrease while system performance increases seemingly without limit. We have applied modern techniques in sensors, electronics and instrumentation to create a suite of ground based diagnostics that can be used in laboratory (~ 1 m2), field scale...

  10. An Inexpensive High-Temporal Resolution Electronic Sun Journal for Monitoring Personal Day to Day Sun Exposure Patterns

    PubMed Central

    Downs, Nathan J.; Parisi, Alfio V.; Butler, Harry; Rawlings, Alex; Elrahoumi, Raja Salem

    2017-01-01

    Exposure to natural sunlight, specifically solar ultraviolet (UV) radiation contributes to lifetime risks of skin cancer, eye disease, and diseases associated with vitamin D insufficiency. Improved knowledge of personal sun exposure patterns can inform public health policy; and help target high-risk population groups. Subsequently, an extensive number of studies have been conducted to measure personal solar UV exposure in a variety of settings. Many of these studies, however, use digital or paper-based journals (self-reported volunteer recall), or employ cost prohibitive electronic UV dosimeters (that limit the size of sample populations), to estimate periods of exposure. A cost effective personal electronic sun journal (ESJ) built from readily available infrared photodiodes is presented in this research. The ESJ can be used to complement traditional UV dosimeters that measure total biologically effective exposure by providing a time-stamped sun exposure record. The ESJ can be easily attached to clothing and data logged to personal devices (including fitness monitors or smartphones). The ESJ improves upon self-reported exposure recording and is a cost effective high-temporal resolution option for monitoring personal sun exposure behavior in large population studies. PMID:29201865

  11. The economics of electronic journals.

    PubMed

    Budd, K W

    2000-01-01

    High print journal subscription costs, access to desktop publishing software, and awareness of Internet capability are among several reasons that interest in the electronic publishing of scholarly journals is increasing rapidly. The economic considerations of electronic publishing are not as familiar, however, although the fingertip accessibility of electronic journals, and in some cases, the lack of subscription charges gives the impression that electronic journal publishing is a much less costly means of publishing. Such an impression receives qualified confirmation in this article as an overview of the costs of scholarly publishing is provided, and the costs of print and electronic journals are compared. Also addressed are ways to recover costs of publishing electronic journals, and predictions for the future of such journals.

  12. Future of electronic health records: implications for decision support.

    PubMed

    Rothman, Brian; Leonard, Joan C; Vigoda, Michael M

    2012-01-01

    The potential benefits of the electronic health record over traditional paper are many, including cost containment, reductions in errors, and improved compliance by utilizing real-time data. The highest functional level of the electronic health record (EHR) is clinical decision support (CDS) and process automation, which are expected to enhance patient health and healthcare. The authors provide an overview of the progress in using patient data more efficiently and effectively through clinical decision support to improve health care delivery, how decision support impacts anesthesia practice, and how some are leading the way using these systems to solve need-specific issues. Clinical decision support uses passive or active decision support to modify clinician behavior through recommendations of specific actions. Recommendations may reduce medication errors, which would result in considerable savings by avoiding adverse drug events. In selected studies, clinical decision support has been shown to decrease the time to follow-up actions, and prediction has proved useful in forecasting patient outcomes, avoiding costs, and correctly prompting treatment plan modifications by clinicians before engaging in decision-making. Clinical documentation accuracy and completeness is improved by an electronic health record and greater relevance of care data is delivered. Clinical decision support may increase clinician adherence to clinical guidelines, but educational workshops may be equally effective. Unintentional consequences of clinical decision support, such as alert desensitization, can decrease the effectiveness of a system. Current anesthesia clinical decision support use includes antibiotic administration timing, improved documentation, more timely billing, and postoperative nausea and vomiting prophylaxis. Electronic health record implementation offers data-mining opportunities to improve operational, financial, and clinical processes. Using electronic health record data in real-time for decision support and process automation has the potential to both reduce costs and improve the quality of patient care. © 2012 Mount Sinai School of Medicine.

  13. Serial Killers: Academic Libraries Respond to Soaring Costs.

    ERIC Educational Resources Information Center

    McCarthy, Paul

    1994-01-01

    Discusses ways in which academic libraries are responding to rising costs of serials. Topics addressed include pricing by publishers; the effect of journal cancellations on research activities; interlibrary loans and document delivery services; coordinated cancelling; electronic journals; and experiences at the University of Arizona. (LRW)

  14. Using Electronic Portfolios

    ERIC Educational Resources Information Center

    Page, Deb

    2012-01-01

    The digitized collections of artifacts known as electronic portfolios are creating solutions to a variety of performance improvement needs in ways that are cost-effective and improve both individual and group learning and performance. When social media functionality is embedded in e-portfolios, the tools support collaboration, social learning,…

  15. 12 CFR 1209.29 - Discovery.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the timely, cost-effective management of document discovery (including, if applicable, electronically... discovery plan shall specify the form of electronic productions, if any. Documents are to be produced in... proceeding under this part may obtain document discovery by serving upon any other party in the proceeding a...

  16. 12 CFR 1209.29 - Discovery.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the timely, cost-effective management of document discovery (including, if applicable, electronically... discovery plan shall specify the form of electronic productions, if any. Documents are to be produced in... proceeding under this part may obtain document discovery by serving upon any other party in the proceeding a...

  17. 12 CFR 1209.29 - Discovery.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the timely, cost-effective management of document discovery (including, if applicable, electronically... discovery plan shall specify the form of electronic productions, if any. Documents are to be produced in... proceeding under this part may obtain document discovery by serving upon any other party in the proceeding a...

  18. Reliability enhancement through optimal burn-in

    NASA Astrophysics Data System (ADS)

    Kuo, W.

    1984-06-01

    A numerical reliability and cost model is defined for production line burn-in tests of electronic components. The necessity of burn-in is governed by upper and lower bounds: burn-in is mandatory for operation-critical or nonreparable component; no burn-in is needed when failure effects are insignificant or easily repairable. The model considers electronic systems in terms of a series of components connected by a single black box. The infant mortality rate is described with a Weibull distribution. Performance reaches a steady state after burn-in, and the cost of burn-in is a linear function for each component. A minimum cost is calculated among the costs and total time of burn-in, shop repair, and field repair, with attention given to possible losses in future sales from inadequate burn-in testing.

  19. Prospective economic evaluation of an electronic discharge communication tool: analysis of a randomised controlled trial

    PubMed Central

    Sevick, Laura K; Santana, Maria-Jose; Ghali, William A; Clement, Fiona

    2017-01-01

    Objective To complete an economic evaluation within a randomised controlled trial (RCT) comparing the use of an electronic discharge communication tool (eDCT) compared with usual care. Setting Patients being discharged from a single tertiary care centre’s internal medicine Medical Teaching Units. Participants Between January 2012 and December 2013, 1399 patients were randomised to a discharge mechanism. Forty-five patients were excluded from the economic evaluation as they did not have data for the index hospitalisation cost; 1354 patients contributed to the economic evaluation. Intervention eDCT generated at discharge containing structured content on reason for admission, details of the hospital stay, treatments received and follow-up care required. The control group was discharged via traditional dictation methods. Primary and secondary outcome measures The primary economic outcome was the cost per quality-adjusted life year (QALY) gained. Secondary outcomes included the cost per death avoided and the cost per readmission avoided. Results The average transcription cost was $C22.28 per patient, whereas the estimated cost of the eDCT was $C13.33 per patient. The cost per QALY gained was $C239 933 in the eDCT arm compared with usual care due to the very small gains in effectiveness and approximately $C800difference in resource utilisation costs. The bootstrap analyses resulted in eDCT being more effective and more costly in 29.2% of samples, less costly and more effective in 29.2% of samples, less effective and more costly in 23.9% of samples and finally, less costly and less effective in 17.7% of samples. Conclusions The eDCT reduced per patient costs of the generation of discharge summaries. The bootstrap estimates demonstrate considerable uncertainty supporting the finding of neutrality reported in the clinical component of the RCT. The immediate transcription cost savings and previously documented provider and patient satisfaction may increase the impetus for organisations to invest in such systems, provided they have a foundation of eHealth infrastructure and readiness. Trial registration number NCT01402609. PMID:29247110

  20. The Nonsubscription Side of Periodicals: Changes in Library Operations and Costs between Print and Electronic Formats

    ERIC Educational Resources Information Center

    Schonfeld, Roger C.; King, Donald W.; Okerson, Ann; Fenton, Eileen Gifford

    2004-01-01

    Many academic and research libraries are in the midst of what may ultimately be a major transition for various parts of their collection--a shift from print to electronic format. Libraries that had long subscribed only to print versions of journals are, in increasing numbers, licensing electronic versions to replace the print. What effects will…

  1. Future opportunities for advancing glucose test device electronics.

    PubMed

    Young, Brian R; Young, Teresa L; Joyce, Margaret K; Kennedy, Spencer I; Atashbar, Massood Z

    2011-09-01

    Advancements in the field of printed electronics can be applied to the field of diabetes testing. A brief history and some new developments in printed electronics components applicable to personal test devices, including circuitry, batteries, transmission devices, displays, and sensors, are presented. Low-cost, thin, and lightweight materials containing printed circuits with energy storage or harvest capability and reactive/display centers, made using new printing/imaging technologies, are ideal for incorporation into personal-use medical devices such as glucose test meters. Semicontinuous rotogravure printing, which utilizes flexible substrates and polymeric, metallic, and/or nano "ink" composite materials to effect rapidly produced, lower-cost printed electronics, is showing promise. Continuing research advancing substrate, "ink," and continuous processing development presents the opportunity for research collaboration with medical device designers. © 2011 Diabetes Technology Society.

  2. A study of low cost approaches to scientific experiment implementation for shuttle launched and serviced automated spacecraft

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Cost reductions that can be obtained in experiment instrumentation by the use of standardized electronics and by the relaxation of instrument reliability requirements are studied. The feasibility of using standardized equipment for experiment instrumentation is assessed and a system design approach that most effectively incorporates standardized equipment is developed. The level and form of modularization that is appropriate for the standardized equipment is determined. Mission assurance aspects of instrument development are examined to determine the cost reductions that might be derived from the relaxation of reliability requirements and to formulate a systematic approach to the optimization of mission assurance cost reductions. The results of the analyses are applied to a representative model HEAO payload in order to provide a concrete example of the cost reductions that can be achieved by a standardized approach to the instrument electronics.

  3. A tutorial on activity-based costing of electronic health records.

    PubMed

    Federowicz, Marie H; Grossman, Mila N; Hayes, Bryant J; Riggs, Joseph

    2010-01-01

    As the American Recovery and Restoration Act of 2009 allocates $19 billion to health information technology, it will be useful for health care managers to project the true cost of implementing an electronic health record (EHR). This study presents a step-by-step guide for using activity-based costing (ABC) to estimate the cost of an EHR. ABC is a cost accounting method with a "top-down" approach for estimating the cost of a project or service within an organization. The total cost to implement an EHR includes obvious costs, such as licensing fees, and hidden costs, such as impact on productivity. Unlike other methods, ABC includes all of the organization's expenditures and is less likely to miss hidden costs. Although ABC is used considerably in manufacturing and other industries, it is a relatively new phenomenon in health care. ABC is a comprehensive approach that the health care field can use to analyze the cost-effectiveness of implementing EHRs. In this article, ABC is applied to a health clinic that recently implemented an EHR, and the clinic is found to be more productive after EHR implementation. This methodology can help health care administrators assess the impact of a stimulus investment on organizational performance.

  4. Operating Room Delays: Meaningful Use in Electronic Health Record.

    PubMed

    Van Winkle, Rachelle A; Champagne, Mary T; Gilman-Mays, Meri; Aucoin, Julia

    2016-06-01

    Perioperative areas are the most costly to operate and account for more than 40% of expenses. The high costs prompted one organization to analyze surgical delays through a retrospective review of their new electronic health record. Electronic health records have made it easier to access and aggregate clinical data; 2123 operating room cases were analyzed. Implementing a new electronic health record system is complex; inaccurate data and poor implementation can introduce new problems. Validating the electronic health record development processes determines the ease of use and the user interface, specifically related to user compliance with the intent of the electronic health record development. The revalidation process after implementation determines if the intent of the design was fulfilled and data can be meaningfully used. In this organization, the data fields completed through automation provided quantifiable, meaningful data. However, data fields completed by staff that required subjective decision making resulted in incomplete data nearly 24% of the time. The ease of use was further complicated by 490 permutations (combinations of delay types and reasons) that were built into the electronic health record. Operating room delay themes emerged notwithstanding the significant complexity of the electronic health record build; however, improved accuracy could improve meaningful data collection and a more accurate root cause analysis of operating room delays. Accurate and meaningful use of data affords a more reliable approach in quality, safety, and cost-effective initiatives.

  5. The Illusion of the Instructional Biology Laboratory.

    ERIC Educational Resources Information Center

    Ralph, Charles L.

    1996-01-01

    Argues that the changing informational content of biology, tightening cost constraints, improving electronic media, increasing pressures from advocates of animal rights, and the growing evidence of the effectiveness of electronic modes of instruction are undermining the traditional belief that all students in biology should have the benefit of…

  6. Use of Commercial Electrical, Electronic and Electromechanical (EEE) Parts in NASA's Commercial Crew Program (CCP)

    NASA Technical Reports Server (NTRS)

    Gonzalex, Oscar

    2012-01-01

    NASA's Commercial Crew and Cargo Program (CCP) is stimulating efforts within the private sector to develop and demonstrate safe, reliable, and cost-effective space transportation capabilities. One initiative involves investigating the use of commercial electronic parts. NASA's CCP asked the NASA Engineering and Safety Center (NESC) to collect data to help frame the technical, cost, and schedule risk trades associated with electrical, electronic and electromechanical (EEE) parts selection and specifically expressed desire of some of the CCP partners to employ EEE parts of a lower grade than traditionally used in most NASA safety-critical applications. This document contains the outcome from the NESC's review and analyses.

  7. Electronic Resource Management 2.0: Using Web 2.0 Technologies as Cost-Effective Alternatives to an Electronic Resource Management System

    ERIC Educational Resources Information Center

    Murray, Adam

    2008-01-01

    Designed to assist with the management of e-resources, electronic resource management (ERM) systems are time- and fund-consuming to purchase and maintain. Questions of system compatibility, data population, and workflow design/redesign can be difficult to answer; sometimes those answers are not what we'd prefer to hear. The two primary functions…

  8. PbSe Nanocrystal Solids for n- and p-Channel Thin Film Field-Effect Transistors

    NASA Astrophysics Data System (ADS)

    Talapin, Dmitri V.; Murray, Christopher B.

    2005-10-01

    Initially poorly conducting PbSe nanocrystal solids (quantum dot arrays or superlattices) can be chemically ``activated'' to fabricate n- and p-channel field effect transistors with electron and hole mobilities of 0.9 and 0.2 square centimeters per volt-second, respectively; with current modulations of about 103 to 104; and with current density approaching 3 × 104 amperes per square centimeter. Chemical treatments engineer the interparticle spacing, electronic coupling, and doping while passivating electronic traps. These nanocrystal field-effect transistors allow reversible switching between n- and p-transport, providing options for complementary metal oxide semiconductor circuits and enabling a range of low-cost, large-area electronic, optoelectronic, thermoelectric, and sensing applications.

  9. 48 CFR 4.502 - Policy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... MATTERS Electronic Commerce in Contracting 4.502 Policy. (a) The Federal Government shall use electronic commerce whenever practicable or cost-effective. The use of terms commonly associated with paper transactions (e.g., “copy,” “document,” “page,” “printed,” “sealed envelope,” and “stamped”) shall not be...

  10. Measuring treatment costs of typical waste electrical and electronic equipment: A pre-research for Chinese policy making.

    PubMed

    Li, Jinhui; Dong, Qingyin; Liu, Lili; Song, Qingbin

    2016-11-01

    Waste Electrical and Electronic Equipment (WEEE) volume is increasing, worldwide. In 2011, the Chinese government issued new regulations on WEEE recycling and disposal, establishing a WEEE treatment subsidy funded by a levy on producers of electrical and electronic equipment. In order to evaluate WEEE recycling treatment costs and revenue possibilities under the new regulations, and to propose suggestions for cost-effective WEEE management, a comprehensive revenue-expenditure model (REM), were established for this study, including 7 types of costs, 4 types of fees, and one type of revenue. Since TV sets dominated the volume of WEEE treated from 2013 to 2014, with a contribution rate of 87.3%, TV sets were taken as a representative case. Results showed that the treatment cost varied from 46.4RMB/unit to 82.5RMB/unit, with a treatment quantity of 130,000 units to 1,200,000 units per year in China. Collection cost accounted for the largest portion (about 70.0%), while taxes and fees (about 11.0 %) and labor cost (about 7.0 %) contributed less. The average costs for disposal, sales, and taxes had no influence on treatment quantity (TQ). TQ might have an adverse effect on average labor and management costs; while average collection and purchase fees, and financing costs, would vary with purchase price, and the average sales fees and taxes would vary with the sales of dismantled materials and other recycled products. Recycling enterprises could reduce their costs by setting up online and offline collection platforms, cooperating with individual collectors, creating door-to-door collection channels, improving production efficiency and reducing administrative expenditures. The government could provide economic incentives-such as subsidies, low-cost loans, tax cuts and credits-and could also raise public awareness of waste management and environmental protection, in order to capture some of the WEEE currently discarded into the general waste stream. Foreign companies with advanced WEEE utilization technology could invest or participate in this area, producing profits for themselves while helping to develop and implement environmentally friendly and energy-saving technologies applicable to the Chinese market. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Effect of an imaging-based streamlined electronic healthcare process on quality and costs.

    PubMed

    Bui, Alex A T; Taira, Ricky K; Goldman, Dana; Dionisio, John David N; Aberle, Denise R; El-Saden, Suzie; Sayre, James; Rice, Thomas; Kangarloo, Hooshang

    2004-01-01

    A streamlined process of care supported by technology and imaging may be effective in managing the overall healthcare process and costs. This study examined the effect of an imaging-based electronic process of care on costs and rates of hospitalization, emergency room (ER) visits, specialist diagnostic referrals, and patient satisfaction. A healthcare process was implemented for an employer group, highlighting improved patient access to primary care plus routine use of imaging and teleconsultation with diagnostic specialists. An electronic infrastructure supported patient access to physicians and communication among healthcare providers. The employer group, a self-insured company, manages a healthcare plan for its employees and their dependents: 4,072 employees were enrolled in the test group, and 7,639 in the control group. Outcome measures for expenses and frequency of hospitalizations, ER visits, traditional specialist referrals, primary care visits, and imaging utilization rates were measured using claims data over 1 year. Homogeneity tests of proportions were performed with a chi-square statistic, mean differences were tested by two-sample t-tests. Patient satisfaction with access to healthcare was gauged using results from an independent firm. Overall per member/per month costs post-implementation were lower in the enrolled population (126 dollars vs 160 dollars), even though occurrence of chronic/expensive diseases was higher in the enrolled group (18.8% vs 12.2%). Lower per member/per month costs were seen for inpatient (33.29 dollars vs 35.59 dollars); specialist referrals (21.36 dollars vs 26.84 dollars); and ER visits (3.68 dollars vs 5.22 dollars). Moreover, the utilization rate for hospital admissions, ER visits, and traditional specialist referrals were significantly lower in the enrolled group, although primary care and imaging utilization were higher. Comparison to similar employer groups showed that the company's costs were lower than national averages (119.24 dollars vs 146.32 dollars), indicating that the observed result was not attributable to normalization effects. Patient satisfaction with access to healthcare ranked in the top 21st percentile. A streamlined healthcare process supported by technology resulted in higher patient satisfaction and cost savings despite improved access to primary care and higher utilization of imaging.

  12. Cost effectiveness of human papilloma virus vaccination in low and middle income countries: a systematic review of literature.

    PubMed

    Silas, Olugbenga Akindele; Achenbach, Chad J; Murphy, Robert Leo; Hou, Lifang; Sagay, Solomon Atiene; Banwat, Edmund; Adoga, Adeyi A; Musa, Jonah; French, Dustin Douglas

    2018-01-01

    Low and middle income countries (LMICs) bear more than 50% of the current cervical cancer burden over the last decade with linkages to lack of HPV vaccination, high levels of poverty, illiteracy and nonexistent or poor screening programs. Governments of LMICs need enough convincing evidence that HPV vaccination will be more cost-effective in reducing the scourge of cervical cancer. Area covered: A systematic review to identify suitable studies from MEDLINE(via PubMed), EMBASE and Electronic search through GOOGLE for original and review articles from 2007 to 2014 on cost-effectiveness of human papilloma virus vaccination of pre-adolescent girls in LMICs was conducted. A total of 19 full articles were finally selected and reviewed after screening out those not consistent with the inclusion and exclusion criteria. Expert commentary: Most studies on cost-effectiveness of HPV vaccine in LMICs show that lowering cost of HPV vaccination with or without Pap smear screening is cost-effective in areas with high incidence of cervical cancer.

  13. Antenna and Electronics Cost Tradeoffs For Large Arrays

    NASA Technical Reports Server (NTRS)

    D'Addario, Larry R.

    2007-01-01

    This viewgraph presentation describes the cost tradeoffs for large antenna arrays. The contents include: 1) Cost modeling for large arrays; 2) Antenna mechanical cost over a wide range of sizes; and 3) Cost of per-antenna electronics.

  14. Intrinsically Stretchable and Conductive Textile by a Scalable Process for Elastic Wearable Electronics.

    PubMed

    Wang, Chunya; Zhang, Mingchao; Xia, Kailun; Gong, Xueqin; Wang, Huimin; Yin, Zhe; Guan, Baolu; Zhang, Yingying

    2017-04-19

    The prosperous development of stretchable electronics poses a great demand on stretchable conductive materials that could maintain their electrical conductivity under tensile strain. Previously reported strategies to obtain stretchable conductors usually involve complex structure-fabricating processes or utilization of high-cost nanomaterials. It remains a great challenge to produce stretchable and conductive materials via a scalable and cost-effective process. Herein, a large-scalable pyrolysis strategy is developed for the fabrication of intrinsically stretchable and conductive textile in utilizing low-cost and mass-produced weft-knitted textiles as raw materials. Due to the intrinsic stretchability of the weft-knitted structure and the excellent mechanical and electrical properties of the as-obtained carbonized fibers, the obtained flexible and durable textile could sustain tensile strains up to 125% while keeping a stable electrical conductivity (as shown by a Modal-based textile), thus ensuring its applications in elastic electronics. For demonstration purposes, stretchable supercapacitors and wearable thermal-therapy devices that showed stable performance with the loading of tensile strains have been fabricated. Considering the simplicity and large scalability of the process, the low-cost and mass production of the raw materials, and the superior performances of the as-obtained elastic and conductive textile, this strategy would contribute to the development and industrial production of wearable electronics.

  15. Collecting verbal autopsies: improving and streamlining data collection processes using electronic tablets.

    PubMed

    Flaxman, Abraham D; Stewart, Andrea; Joseph, Jonathan C; Alam, Nurul; Alam, Sayed Saidul; Chowdhury, Hafizur; Mooney, Meghan D; Rampatige, Rasika; Remolador, Hazel; Sanvictores, Diozele; Serina, Peter T; Streatfield, Peter Kim; Tallo, Veronica; Murray, Christopher J L; Hernandez, Bernardo; Lopez, Alan D; Riley, Ian Douglas

    2018-02-01

    There is increasing interest in using verbal autopsy to produce nationally representative population-level estimates of causes of death. However, the burden of processing a large quantity of surveys collected with paper and pencil has been a barrier to scaling up verbal autopsy surveillance. Direct electronic data capture has been used in other large-scale surveys and can be used in verbal autopsy as well, to reduce time and cost of going from collected data to actionable information. We collected verbal autopsy interviews using paper and pencil and using electronic tablets at two sites, and measured the cost and time required to process the surveys for analysis. From these cost and time data, we extrapolated costs associated with conducting large-scale surveillance with verbal autopsy. We found that the median time between data collection and data entry for surveys collected on paper and pencil was approximately 3 months. For surveys collected on electronic tablets, this was less than 2 days. For small-scale surveys, we found that the upfront costs of purchasing electronic tablets was the primary cost and resulted in a higher total cost. For large-scale surveys, the costs associated with data entry exceeded the cost of the tablets, so electronic data capture provides both a quicker and cheaper method of data collection. As countries increase verbal autopsy surveillance, it is important to consider the best way to design sustainable systems for data collection. Electronic data capture has the potential to greatly reduce the time and costs associated with data collection. For long-term, large-scale surveillance required by national vital statistical systems, electronic data capture reduces costs and allows data to be available sooner.

  16. Cost considerations in using simulations for medical training.

    PubMed

    Fletcher, J D; Wind, Alexander P

    2013-10-01

    This article reviews simulation used for medical training, techniques for assessing simulation-based training, and cost analyses that can be included in such assessments. Simulation in medical training appears to take four general forms: human actors who are taught to simulate illnesses and ailments in standardized ways; virtual patients who are generally presented via computer-controlled, multimedia displays; full-body manikins that simulate patients using electronic sensors, responders, and controls; and part-task anatomical simulations of various body parts and systems. Techniques for assessing costs include benefit-cost analysis, return on investment, and cost-effectiveness analysis. Techniques for assessing the effectiveness of simulation-based medical training include the use of transfer effectiveness ratios and incremental transfer effectiveness ratios to measure transfer of knowledge and skill provided by simulation to the performance of medical procedures. Assessment of costs and simulation effectiveness can be combined with measures of transfer using techniques such as isoperformance analysis to identify ways of minimizing costs without reducing performance effectiveness or maximizing performance without increasing costs. In sum, economic analysis must be considered in training assessments if training budgets are to compete successfully with other requirements for funding. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.

  17. Competitive bidding for health insurance contracts: lessons from the online HMO auctions.

    PubMed

    Gupta, Alok; Parente, Stephen T; Sanyal, Pallab

    2012-12-01

    Healthcare is an important social and economic component of modern society, and the effective use of information technology in this industry is critical to its success. As health insurance premiums continue to rise, competitive bidding may be useful in generating stronger price competition and lower premium costs for employers and possibly, government agencies. In this paper, we assess an endeavor by several Fortune 500 companies to reduce healthcare procurement costs for their employees by having HMOs compete in open electronic auctions. Although the auctions were successful in generating significant cost savings for the companies in the first year, i.e., 1999, they failed to replicate the success and were eventually discontinued after two more years. Over the past decade since the failed auction experiment, effective utilization of information technologies have led to significant advances in the design of complex electronic markets. Using this knowledge, and data from the auctions, we point out several shortcomings of the auction design that, we believe, led to the discontinuation of the market after three years. Based on our analysis, we propose several actionable recommendations that policy makers can use to design a sustainable electronic market for procuring health insurance.

  18. Practicality of electronic beam steering for MST/ST radars, part 6.2A

    NASA Technical Reports Server (NTRS)

    Clark, W. L.; Green, J. L.

    1984-01-01

    Electronic beam steering is described as complex and expensive. The Sunset implementation of electronic steering is described, and it is demonstrated that such systems are cost effective, versatile, and no more complex than fixed beam alternatives, provided three or more beams are needed. The problem of determining accurate meteorological wind components in the presence of spatial variation is considered. A cost comparison of steerable and fixed systems allowing solution of this problem is given. The concepts and relations involved in phase steering are given, followed by the description of the Sunset ST radar steering system. The implications are discussed, references to the competing SAD method are provided, and a recommendation concerning the design of the future Doppler ST/MST systems is made.

  19. Library Economic Metrics: Examples of the Comparison of Electronic and Print Journal Collections and Collection Services.

    ERIC Educational Resources Information Center

    King, Donald W.; Boyce, Peter B.; Montgomery, Carol Hansen; Tenopir, Carol

    2003-01-01

    Focuses on library economic metrics, and presents a conceptual framework for library economic metrics including service input and output, performance, usage, effectiveness, outcomes, impact, and cost and benefit comparisons. Gives examples of these measures for comparison of library electronic and print collections and collection services.…

  20. Staying on your your feet.

    PubMed

    DeGaspari, John

    2011-10-01

    CIOs are hard at work coming up with the most effective and affordable strategies for protecting electronic data as their hospitals move forward on electronic medical records. While the rise of cloud computing and declining network costs are offering new opportunities in dealing with potential disasters, many find there is no substitute for good planning and constant testing.

  1. Screen printing as a scalable and low-cost approach for rigid and flexible thin-film transistors using separated carbon nanotubes.

    PubMed

    Cao, Xuan; Chen, Haitian; Gu, Xiaofei; Liu, Bilu; Wang, Wenli; Cao, Yu; Wu, Fanqi; Zhou, Chongwu

    2014-12-23

    Semiconducting single-wall carbon nanotubes are very promising materials in printed electronics due to their excellent mechanical and electrical property, outstanding printability, and great potential for flexible electronics. Nonetheless, developing scalable and low-cost approaches for manufacturing fully printed high-performance single-wall carbon nanotube thin-film transistors remains a major challenge. Here we report that screen printing, which is a simple, scalable, and cost-effective technique, can be used to produce both rigid and flexible thin-film transistors using separated single-wall carbon nanotubes. Our fully printed top-gated nanotube thin-film transistors on rigid and flexible substrates exhibit decent performance, with mobility up to 7.67 cm2 V(-1) s(-1), on/off ratio of 10(4)∼10(5), minimal hysteresis, and low operation voltage (<10 V). In addition, outstanding mechanical flexibility of printed nanotube thin-film transistors (bent with radius of curvature down to 3 mm) and driving capability for organic light-emitting diode have been demonstrated. Given the high performance of the fully screen-printed single-wall carbon nanotube thin-film transistors, we believe screen printing stands as a low-cost, scalable, and reliable approach to manufacture high-performance nanotube thin-film transistors for application in display electronics. Moreover, this technique may be used to fabricate thin-film transistors based on other materials for large-area flexible macroelectronics, and low-cost display electronics.

  2. "Cut-and-paste" manufacture of multiparametric epidermal electronic systems

    NASA Astrophysics Data System (ADS)

    Lu, Nanshu; Yang, Shixuan; Wang, Pulin

    2016-05-01

    Epidermal electronics is a class of noninvasive and unobstructive skin-mounted, tattoo-like sensors and electronics capable of vital sign monitoring and establishing human-machine interface. The high cost of manpower, materials, vacuum equipment, and photolithographic facilities associated with its manufacture greatly hinders the widespread use of disposable epidermal electronics. Here we report a cost and time effective, completely dry, benchtop "cut-and-paste" method for the freeform and portable manufacture of multiparametric epidermal sensor systems (ESS) within minutes. This versatile method works for all types of thin metal and polymeric sheets and is compatible with any tattoo adhesives or medical tapes. The resulting ESS are multimaterial and multifunctional and have been demonstrated to noninvasively but accurately measure electrophysiological signals, skin temperature, skin hydration, as well as respiratory rate. In addition, planar stretchable coils exploiting double-stranded serpentine design have been successfully applied as wireless, passive epidermal strain sensors.

  3. Costs and Outcomes of Increasing Access to Bariatric Surgery: Cohort Study and Cost-Effectiveness Analysis Using Electronic Health Records.

    PubMed

    Gulliford, Martin C; Charlton, Judith; Prevost, Toby; Booth, Helen; Fildes, Alison; Ashworth, Mark; Littlejohns, Peter; Reddy, Marcus; Khan, Omar; Rudisill, Caroline

    2017-01-01

    To estimate costs and outcomes of increasing access to bariatric surgery in obese adults and in population subgroups of age, sex, deprivation, comorbidity, and obesity category. A cohort study was conducted using primary care electronic health records, with linked hospital utilization data, for 3,045 participants who underwent bariatric surgery and 247,537 participants who did not undergo bariatric surgery. Epidemiological analyses informed a probabilistic Markov model to compare bariatric surgery, including equal proportions with adjustable gastric banding, gastric bypass, and sleeve gastrectomy, with standard nonsurgical management of obesity. Outcomes were quality-adjusted life-years (QALYs) and net monetary benefits at a threshold of £30,000 per QALY. In a UK population of 250,000 adults, there may be 7,163 people with morbid obesity including 1,406 with diabetes. The immediate cost of 1,000 bariatric surgical procedures is £9.16 million, with incremental discounted lifetime health care costs of £15.26 million (95% confidence interval £15.18-£15.36 million). Patient-years with diabetes mellitus will decrease by 8,320 (range 8,123-8,502). Incremental QALYs will increase by 2,142 (range 2,032-2,256). The estimated cost per QALY gained is £7,129 (range £6,775-£7,506). Net monetary benefits will be £49.02 million (range £45.72-£52.41 million). Estimates are similar for subgroups of age, sex, and deprivation. Bariatric surgery remains cost-effective if the procedure is twice as costly, or if intervention effect declines over time. Diverse obese individuals may benefit from bariatric surgery at acceptable cost. Bariatric surgery is not cost-saving, but increased health care costs are exceeded by health benefits to obese individuals. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  4. Systematic Review of the Cost and Cost-Effectiveness of Rapid Endovascular Therapy for Acute Ischemic Stroke.

    PubMed

    Sevick, Laura K; Ghali, Sarah; Hill, Michael D; Danthurebandara, Vishva; Lorenzetti, Diane L; Noseworthy, Tom; Spackman, Eldon; Clement, Fiona

    2017-09-01

    Rapid endovascular therapy (EVT) is an emerging treatment option for acute ischemic stroke. Several economic evaluations have been published examining the cost-effectiveness of EVT, and many international bodies are currently making adoption decisions. The objective of this study was to establish the cost-effectiveness of EVT for ischemic stroke patients and to synthesize all the publicly available economic literature. A systematic review of the published literature was conducted to identify economic evaluations and cost analyses of EVT for acute ischemic stroke patients. Systematic review best practices were followed, and study quality was assessed. Four-hundred sixty-three articles were identified from electronic databases. After deduplication, abstract review, and full-text review, 17 studies were included. Seven of the studies were cost analyses, and 10 were cost-effectiveness studies. Generally, the cost analyses reported on the cost of the approach/procedure or the hospitalization costs associated with EVT. All of the cost-effectiveness studies reported a cost per quality-adjusted life year as the primary outcomes. Studies varied in regards to the costs considered, the perspective adopted, and the time horizon used. All the studies reported a cost per quality-adjusted life year of <$50 000 as the primary outcome. There is a robust body of evidence for the cost and cost-effectiveness of EVT. The cost analyses suggested that although EVT was associated with higher costs, it also resulted in improved patient outcomes. From the cost-effectiveness studies, EVT seems to be good value for money when a threshold of $50 000 per quality-adjusted life year gained is adopted. © 2017 American Heart Association, Inc.

  5. Diagnostic value and cost-effectiveness of good quality digital images accompanying electronic referrals for suspected skin malignancies.

    PubMed

    Ng, Michael F Y; Stevenson, J Howard

    2011-04-01

    The aim of this study was to investigate the outcome and cost-effectiveness of good and poor quality photographs accompanying the electronic referrals for suspected skin malignancies. A retrospective study of 100 patients, divided into 2 groups, 50 with good quality photographs and 50 with poor quality photographs. Patients with no digital images, or who failed to attend, or patients with incomplete notes were excluded from the study. The treatment pathway, waiting times, and estimated cost between the 2 groups were compared. Good photographs were more likely to be treated at the 1-Stop Clinic (P = 0.05). Good images had a better positive predictive value than poor quality images (62.55% vs. 42.86%). Good quality images are more accurate than poor quality images in triaging of patients, and thus more effective in facilitating the treatment of malignant lesions timely. Good quality photographs allow a delayed appropriate treatment of benign lesions. This increases the safety for patients in a queue in a rationed health care system, and improves patient flow.

  6. Cost-effectiveness of surgical interventions for the management of osteoarthritis: a systematic review of the literature.

    PubMed

    Kamaruzaman, Hanin; Kinghorn, Philip; Oppong, Raymond

    2017-05-10

    The primary purpose of this study is to assess the existing evidence on the cost-effectiveness of surgical interventions for the management of knee and hip osteoarthritis by systematically reviewing published economic evaluation studies. A systematic review was conducted for the period 2004 to 2016. Electronic databases were searched to identify both trial and model based economic evaluation studies that evaluated surgical interventions for knee and hip osteoarthritis. A total of 23 studies met the inclusion criteria and an assessment of these studies showed that total knee arthroplasty (TKA), and total hip arthroplasty (THA) showed evidence of cost-effectiveness and improvement in quality of life of the patients when compared to non-operative and non-surgical procedures. On the other hand, even though delaying TKA and THA may lead to some cost savings in the short-run, the results from the study showed that this was not a cost-effective option. TKA and THA are cost-effective and should be recommended for the management of patients with end stage/severe knee and hip OA. However, there needs to be additional studies to assess the cost-effectiveness of other surgical interventions in order for definite conclusions to be reached.

  7. Ion thruster performance model

    NASA Technical Reports Server (NTRS)

    Brophy, J. R.

    1984-01-01

    A model of ion thruster performance is developed for high flux density, cusped magnetic field thruster designs. This model is formulated in terms of the average energy required to produce an ion in the discharge chamber plasma and the fraction of these ions that are extracted to form the beam. The direct loss of high energy (primary) electrons from the plasma to the anode is shown to have a major effect on thruster performance. The model provides simple algebraic equations enabling one to calculate the beam ion energy cost, the average discharge chamber plasma ion energy cost, the primary electron density, the primary-to-Maxwellian electron density ratio and the Maxwellian electron temperature. Experiments indicate that the model correctly predicts the variation in plasma ion energy cost for changes in propellant gas (Ar, Kr and Xe), grid transparency to neutral atoms, beam extraction area, discharge voltage, and discharge chamber wall temperature. The model and experiments indicate that thruster performance may be described in terms of only four thruster configuration dependent parameters and two operating parameters. The model also suggests that improved performance should be exhibited by thruster designs which extract a large fraction of the ions produced in the discharge chamber, which have good primary electron and neutral atom containment and which operate at high propellant flow rates.

  8. User-experience surveys with maternity services: a randomized comparison of two data collection models.

    PubMed

    Bjertnaes, Oyvind Andresen; Iversen, Hilde Hestad

    2012-08-01

    To compare two ways of combining postal and electronic data collection for a maternity services user-experience survey. Cross-sectional survey. Maternity services in Norway. All women who gave birth at a university hospital in Norway between 1 June and 27 July 2010. Patients were randomized into the following groups (n= 752): Group A, who were posted questionnaires with both electronic and paper response options for both the initial and reminder postal requests; and Group B, who were posted questionnaires with an electronic response option for the initial request, and both electronic and paper response options for the reminder postal request. Response rate, the amount of difference in background variables between respondents and non-respondents, main study results and estimated cost-effectiveness. The final response rate was significantly higher in Group A (51.9%) than Group B (41.1%). None of the background variables differed significantly between the respondents and non-respondents in Group A, while two variables differed significantly between the respondents and non-respondents in Group B. None of the 11 user-experience scales differed significantly between Groups A and B. The estimated costs per response for the forthcoming national survey was €11.7 for data collection Model A and €9.0 for Model B. The model with electronic-only response option in the first request had lowest response rate. However, this model performed equal to the other model on non-response bias and better on estimated cost-effectiveness, and is the better of the two models in large-scale user experiences surveys with maternity services.

  9. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication.

    PubMed

    Meloni, Gabriel N; Bertotti, Mauro

    2017-01-01

    A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder.

  10. 3D printing scanning electron microscopy sample holders: A quick and cost effective alternative for custom holder fabrication

    PubMed Central

    Bertotti, Mauro

    2017-01-01

    A simple and cost effective alternative for fabricating custom Scanning Electron Microscope (SEM) sample holders using 3D printers and conductive polylactic acid filament is presented. The flexibility of the 3D printing process allowed for the fabrication of sample holders with specific features that enable the high-resolution imaging of nanoelectrodes and nanopipettes. The precise value of the inner semi cone angle of the nanopipettes taper was extracted from the acquired images and used for calculating their radius using electrochemical methods. Because of the low electrical resistivity presented by the 3D printed holder, the imaging of non-conductive nanomaterials, such as alumina powder, was found to be possible. The fabrication time for each sample holder was under 30 minutes and the average cost was less than $0.50 per piece. Despite being quick and economical to fabricate, the sample holders were found to be sufficiently resistant, allowing for multiple uses of the same holder. PMID:28753638

  11. Thermal Management and Reliability of Power Electronics and Electric Machines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narumanchi, Sreekant

    2016-09-19

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, andmore » in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.« less

  12. Automatic electronic fish tracking system

    NASA Technical Reports Server (NTRS)

    Osborne, P. W.; Hoffman, E.; Merriner, J. V.; Richards, C. E.; Lovelady, R. W.

    1976-01-01

    A newly developed electronic fish tracking system to automatically monitor the movements and migratory habits of fish is reported. The system is aimed particularly at studies of effects on fish life of industrial facilities which use rivers or lakes to dump their effluents. Location of fish is acquired by means of acoustic links from the fish to underwater Listening Stations, and by radio links which relay tracking information to a shore-based Data Base. Fish over 4 inches long may be tracked over a 5 x 5 mile area. The electronic fish tracking system provides the marine scientist with electronics which permit studies that were not practical in the past and which are cost-effective compared to manual methods.

  13. A review of cost-effectiveness, cost-containment and economics curricula in graduate medical education.

    PubMed

    Varkey, Prathibha; Murad, Mohammad H; Braun, Chad; Grall, Kristi J H; Saoji, Vivek

    2010-12-01

    Numerous studies performed over the last 30 years suggest that doctors have poor knowledge of the costs of medical care. In most graduate medical education programmes, trainees do not receive formal training in cost-effective medical practice. Comprehensive literature search of electronic bibliographic databases for articles that describe health economics, cost-containment and cost-effectiveness curricula in graduate medical education. Critical appraisal of the literature and qualitative description is presented. Heterogeneity of curricula precluded quantitative summary of data. We identified 40 articles that met the inclusion criteria for this review. Internal medicine residents were the targeted learners in 27 studies (68%); Family Medicine and Surgery residents were each targeted in five studies (13%); Rehabilitation, Paediatrics and Emergency Medicine residents were each targeted in one study. In general, the methodological quality of the included studies was poor to moderate and mostly targeted knowledge of health economics or cost-containment as opposed to targeting cost-effectiveness. In terms of describing the standard curricular components, studies sufficiently described the different educational strategies (e.g. didactics, interactive, experiential, self-directed) and the component of learner assessment, but lacked the description of other elements such as needs assessment and curriculum evaluation. Cost-effectiveness curricula in graduate medical education are lacking and clearly needed. © 2010 Blackwell Publishing Ltd.

  14. Real Time Optimal Control of Supercapacitor Operation for Frequency Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luo, Yusheng; Panwar, Mayank; Mohanpurkar, Manish

    2016-07-01

    Supercapacitors are gaining wider applications in power systems due to fast dynamic response. Utilizing supercapacitors by means of power electronics interfaces for power compensation is a proven effective technique. For applications such as requency restoration if the cost of supercapacitors maintenance as well as the energy loss on the power electronics interfaces are addressed. It is infeasible to use traditional optimization control methods to mitigate the impacts of frequent cycling. This paper proposes a Front End Controller (FEC) using Generalized Predictive Control featuring real time receding optimization. The optimization constraints are based on cost and thermal management to enhance tomore » the utilization efficiency of supercapacitors. A rigorous mathematical derivation is conducted and test results acquired from Digital Real Time Simulator are provided to demonstrate effectiveness.« less

  15. A COST EFFECTIVE MULTI-SPECTRAL SCANNER FOR NATURAL GAS DETECTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yudaya Sivathanu; Jongmook Lim; Vinoo Narayanan

    The objective of this project is to design, fabricate and field demonstrate a cost effective, multi-spectral scanner for natural gas leak detection in transmission and distribution pipelines. During the first six months of the project, the design for a laboratory version of the multispectral scanner was completed. The optical, mechanical, and electronic design for the scanner was completed. The optical design was analyzed using Zeemax Optical Design software and found to provide sufficiently resolved performance for the scanner. The electronic design was evaluated using a bread board and very high signal to noise ratios were obtained. Fabrication of a laboratorymore » version of the multi-spectral scanner is currently in progress. A technology status report and a research management plan was also completed during the same period.« less

  16. A comparative study of graphene and graphite-based field effect transistor on flexible substrate

    NASA Astrophysics Data System (ADS)

    Bhatt, Kapil; Rani, Cheenu; Vaid, Monika; Kapoor, Ankit; Kumar, Pramod; Kumar, Sandeep; Shriwastawa, Shilpi; Sharma, Sandeep; Singh, Randhir; Tripathi, C. C.

    2018-06-01

    In the present era, there has been a great demand of cost-effective, biodegradable, flexible and wearable electronics which may open the gate to many applications like flexible displays, RFID tags, health monitoring devices, etc. Due to the versatile nature of plastic substrates, they have been extensively used in packaging, printing, etc. However, the fabrication of electronic devices requires specially prepared substrates with high quality surfaces, chemical compositions and solutions to the related fabrication issues along with its non-biodegradable nature. Therefore, in this report, a cost-effective, biodegradable cellulose paper as an alternative dielectric substrate material for the fabrication of flexible field effect transistor (FET) is presented. The graphite and liquid phase exfoliated graphene have been used as the material for the realisation of source, drain and channel on cellulose paper substrate for its comparative analysis. The mobility of fabricated FETs was calculated to be 83 cm2/V s (holes) and 33 cm2/V s (electrons) for graphite FET and 100 cm2/V s (holes) and 52 cm2/V s (electrons) for graphene FET, respectively. The output characteristic of the device demonstrates the linear behaviour and a comprehensive increase in conductance as a function of gate voltages. The fabricated FETs may be used for strain sensing, health care monitoring devices, human motion detection, etc.

  17. Improving Effectiveness of Bioremediation at DNAPL Source Zone Sites by Applying Partitioning Electron Donors (PEDs)

    DTIC Science & Technology

    2014-05-01

    as trichloroethene (TCE) and tetrachloroethene (PCE). EISB typically relies on the addition of electron donor formulations to enhance the rate of... value (NPV) cost when applied using passive (i.e., biostimulation) methods. Hence, the selection of electron donors has a major implication on EISB...Engineering Service Center NAVFACSW NAVFAC Southwest nBA n-Butyl acetate nBuOH n-Butanol nHEX n-Hexanol NPV net present value O&M operation and

  18. Comparative Cost-Effectiveness Analysis of Three Different Automated Medication Systems Implemented in a Danish Hospital Setting.

    PubMed

    Risør, Bettina Wulff; Lisby, Marianne; Sørensen, Jan

    2018-02-01

    Automated medication systems have been found to reduce errors in the medication process, but little is known about the cost-effectiveness of such systems. The objective of this study was to perform a model-based indirect cost-effectiveness comparison of three different, real-world automated medication systems compared with current standard practice. The considered automated medication systems were a patient-specific automated medication system (psAMS), a non-patient-specific automated medication system (npsAMS), and a complex automated medication system (cAMS). The economic evaluation used original effect and cost data from prospective, controlled, before-and-after studies of medication systems implemented at a Danish hematological ward and an acute medical unit. Effectiveness was described as the proportion of clinical and procedural error opportunities that were associated with one or more errors. An error was defined as a deviation from the electronic prescription, from standard hospital policy, or from written procedures. The cost assessment was based on 6-month standardization of observed cost data. The model-based comparative cost-effectiveness analyses were conducted with system-specific assumptions of the effect size and costs in scenarios with consumptions of 15,000, 30,000, and 45,000 doses per 6-month period. With 30,000 doses the cost-effectiveness model showed that the cost-effectiveness ratio expressed as the cost per avoided clinical error was €24 for the psAMS, €26 for the npsAMS, and €386 for the cAMS. Comparison of the cost-effectiveness of the three systems in relation to different valuations of an avoided error showed that the psAMS was the most cost-effective system regardless of error type or valuation. The model-based indirect comparison against the conventional practice showed that psAMS and npsAMS were more cost-effective than the cAMS alternative, and that psAMS was more cost-effective than npsAMS.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zayas, Jose; Derby, Mike; Ralston, Kiersten

    Atmosphere to Electrons (A2e) is a multi-year U.S. Department of Energy (DOE) research initiative targeting significant reductions in the cost of wind energy through an improved understanding of the complex physics governing electricity generation by wind plants. The goal of A2e is to ensure future wind plants are sited, built, and operated in a way that produces the most cost-effective, usable electric power.

  20. Generation of magneto-immersed electron beams

    NASA Astrophysics Data System (ADS)

    Pikin, A.; Raparia, D.

    2018-05-01

    There are many applications of electron beams in accelerator facilities: for electron coolers, electron lenses, and electron beam ion sources (EBIS) to mention a few. Most of these applications require magnetic compression of the electron beam to reduce the beam radius with the goal of either matching the circulating ion beam (electron lenses and electron coolers) or increasing the ionization capability for the production of highly charged ions (EBIS). The magnetic compression of the electron beam comes at a cost of increasing share of the transverse component of energy and therefore increased angles of the electron trajectories to the longitudinal axis. Considering the effect of the magnetic mirror, it is highly desirable to produce a laminar electron beam in the electron gun. The analysis of electron guns with different configurations is given in this paper with emphasis on generating laminar electron beams.

  1. Radio-frequency flexible and stretchable electronics: the need, challenges and opportunities

    NASA Astrophysics Data System (ADS)

    Jung, Yei Hwan; Seo, Jung-Hun; Zhang, Huilong; Lee, Juhwan; Cho, Sang June; Chang, Tzu-Hsuan; Ma, Zhenqiang

    2017-05-01

    Successful integration of ultrathin flexible or stretchable systems with new applications, such as medical devices and biodegradable electronics, have intrigued many researchers and industries around the globe to seek materials and processes to create high-performance, non-invasive and cost-effective electronics to match those of state-of-the-art devices. Nevertheless, the crucial concept of transmitting data or power wirelessly for such unconventional devices has been difficult to realize due to limitations of radio-frequency (RF) electronics in individual components that form a wireless circuitry, such as antenna, transmission line, active devices, passive devices etc. To overcome such challenges, these components must be developed in a step-by-step manner, as each component faces a number of different challenges in ultrathin formats. Here, we report on materials and design considerations for fabricating flexible and stretchable electronics systems that operate in the microwave level. High-speed flexible active devices, including cost effective Si-based strained MOSFETs, GaAs-based HBTs and GaN-based HEMTs, performing at multi-gigahertz frequencies are presented. Furthermore, flexible or stretchable passive devices, including capacitors, inductors and transmission lines that are vital parts of a microwave circuitry are also demonstrated. We also present unique applications using the presented flexible or stretchable RF components, including wearable RF electronics and biodegradable RF electronics, which were impossible to achieve using conventional rigid, wafer-based technology. Further opportunities like implantable systems exist utilizing such ultrathin RF components, which are discussed in this report as well.

  2. The Cost of Publishing an Electronic Journal: A General Model and a Case Study.

    ERIC Educational Resources Information Center

    Bot, Marjolein; Burgemeester, Johan; Roes, Hans

    1998-01-01

    Describes the Electronic Journal of Comparative Law (EJCL) project from Tilburg University and Utrecht University (Netherlands). A general costing model was developed to chart shared and direct costs of producing electronic journals. Data from the developing/publishing EJCL were used to illustrated the application of this model and to assess the…

  3. Joint Services Electronics Program.

    DTIC Science & Technology

    1980-05-01

    STATEMMEN A Approved for public release, COD Distribution Unlimited.99 Joint Services Electronics Program* _-ANNUAL PROGRESS RP O. 93) 7 / Covering Period...and the temperature dependence of that (dispersive transport) trap limited mobility has shown interesting new effects. Publications of the Research...Low-Cost Laboratory Computer Interface System," (Scheduled for publication May, 1980, Review ot Scinti’i3 Instruments). | i III. INFORMATION

  4. The social act of electronic medication prescribing.

    PubMed

    Aarts, Jos

    2013-01-01

    Prescribing medication is embedded in social norms and cultures. In modern Western health care professionals and policy makers have attempted to rationalize medicine by addressing cost-effectiveness of diagnostic and therapeutic treatments and the development of guidelines and protocols based on the outcomes of clinical studies. These notions of cost-effectiveness and evidence-based medicine have also been embedded in technology such as electronic prescribing systems. Such constraining systems may clash with the reality of clinical practice, where formal boundaries of responsibility and authorization are often blurred. Such systems may therefore even impede patient care. Medication is seen as the essence of medical practice. Prescribing is a social act. In a hospital medications may be aimed at treating a patient for a specific condition, in primary care the professional often meets the patient with her or his social and cultural notions of a health problem. The author argues that the design and implementation of electronic prescribing systems should address the social and cultural context of prescribing. Especially in primary care, where health problems are often ill defined and evidence-based medicine guidelines do not always work as intended, studies need to take into account the sociotechnical character of electronic prescribing systems.

  5. Cost of Operating Central Cancer Registries and Factors That Affect Cost: Findings From an Economic Evaluation of Centers for Disease Control and Prevention National Program of Cancer Registries.

    PubMed

    Tangka, Florence K L; Subramanian, Sujha; Beebe, Maggie Cole; Weir, Hannah K; Trebino, Diana; Babcock, Frances; Ewing, Jean

    2016-01-01

    The Centers for Disease Control and Prevention (CDC) evaluated the economics of the National Program of Cancer Registries to provide the CDC, the registries, and policy makers with the economics evidence-base to make optimal decisions about resource allocation. Cancer registry budgets are under increasing threat, and, therefore, systematic assessment of the cost will identify approaches to improve the efficiencies of this vital data collection operation and also justify the funding required to sustain registry operations. To estimate the cost of cancer registry operations and to assess the factors affecting the cost per case reported by National Program of Cancer Registries-funded central cancer registries. We developed a Web-based cost assessment tool to collect 3 years of data (2009-2011) from each National Program of Cancer Registries-funded registry for all actual expenditures for registry activities (including those funded by other sources) and factors affecting registry operations. We used a random-effects regression model to estimate the impact of various factors on cost per cancer case reported. The cost of reporting a cancer case varied across the registries. Central cancer registries that receive high-quality data from reporting sources (as measured by the percentage of records passing automatic edits) and electronic data submissions, and those that collect and report on a large volume of cases had significantly lower cost per case. The volume of cases reported had a large effect, with low-volume registries experiencing much higher cost per case than medium- or high-volume registries. Our results suggest that registries operate with substantial fixed or semivariable costs. Therefore, sharing fixed costs among low-volume contiguous state registries, whenever possible, and centralization of certain processes can result in economies of scale. Approaches to improve quality of data submitted and increasing electronic reporting can also reduce cost.

  6. Cost of Operating Central Cancer Registries and Factors That Affect Cost: Findings From an Economic Evaluation of Centers for Disease Control and Prevention National Program of Cancer Registries

    PubMed Central

    Tangka, Florence K. L.; Subramanian, Sujha; Beebe, Maggie Cole; Weir, Hannah K.; Trebino, Diana; Babcock, Frances; Ewing, Jean

    2016-01-01

    Context The Centers for Disease Control and Prevention evaluated the economics of the National Program of Cancer Registries to provide the Centers for Disease Control and Prevention, the registries, and policy makers with the economic evidence-base to make optimal decisions about resource allocation. Cancer registry budgets are under increasing threat, and, therefore, systematic assessment of the cost will identify approaches to improve the efficiencies of this vital data collection operation and also justify the funding required to sustain registry operations. Objectives To estimate the cost of cancer registry operations and to assess the factors affecting the cost per case reported by National Program of Cancer Registries–funded central cancer registries. Methods We developed a Web-based cost assessment tool to collect 3 years of data (2009-2011) from each National Program of Cancer Registries–funded registry for all actual expenditures for registry activities (including those funded by other sources) and factors affecting registry operations. We used a random-effects regression model to estimate the impact of various factors on cost per cancer case reported. Results The cost of reporting a cancer case varied across the registries. Central cancer registries that receive high-quality data from reporting sources (as measured by the percentage of records passing automatic edits) and electronic data submissions, and those that collect and report on a large volume of cases had significantly lower cost per case. The volume of cases reported had a large effect, with low-volume registries experiencing much higher cost per case than medium- or high-volume registries. Conclusions Our results suggest that registries operate with substantial fixed or semivariable costs. Therefore, sharing fixed costs among low-volume contiguous state registries, whenever possible, and centralization of certain processes can result in economies of scale. Approaches to improve quality of data submitted and increasing electronic reporting can also reduce cost. PMID:26642226

  7. Using cost-effectiveness analysis to sharpen formulary decision-making: the example of tiotropium at the Veterans Affairs health care system.

    PubMed

    Onukwugha, Ebere; Mullins, C Daniel; DeLisle, Sylvain

    2008-01-01

    To identify a cost-saving subset of criteria for the use of tiotropium at a Veterans Affairs Medical Center based on a cost-effectiveness analysis with ipratropium as the comparator. Retrospective analysis of electronic medical records for the calendar year 2004 was conducted. The sample was drawn from a population at the Baltimore Veterans Affairs Medical Center that had a confirmed diagnosis of chronic obstructive pulmonary disease (COPD) and had filled prescriptions for ipratropium. The tiotropium sample was based on a modeled cohort of COPD patients who had received tiotropium. The analysis was conducted from the perspective of the Veterans Affairs Health Care System. The outcome was the incremental cost-effectiveness of tiotropium versus ipratropium. The incremental cost-effectiveness ratio (ICER) was $2360 per avoided exacerbation. Tiotropium cost-effectiveness increased with COPD severity and was cost-saving in patients with very severe disease (ICER = $-1818) and in patients with a previous COPD-related hospitalization (ICER = $-4472). The ICER was most sensitive to the relative effectiveness and price of tiotropium. Results identified the levels of treatment effectiveness and price beyond which tiotropium would become cost-saving relative to ipratropium. The results support the existing Veterans Affairs practice of offering tiotropium to patients with COPD-related hospitalizations. Periodic review of the effectiveness data to determine whether tiotropium would be cost-saving in patients with very severe COPD is suggested. Cost-effectiveness analyses that identify practical criteria-for-use should become an integral part of the formulary process.

  8. Cost-benefit study of consumer product take-back programs using IBM's WIT reverse logistics optimization tool

    NASA Astrophysics Data System (ADS)

    Veerakamolmal, Pitipong; Lee, Yung-Joon; Fasano, J. P.; Hale, Rhea; Jacques, Mary

    2002-02-01

    In recent years, there has been increased focus by regulators, manufacturers, and consumers on the issue of product end of life management for electronics. This paper presents an overview of a conceptual study designed to examine the costs and benefits of several different Product Take Back (PTB) scenarios for used electronics equipment. The study utilized a reverse logistics supply chain model to examine the effects of several different factors in PTB programs. The model was done using the IBM supply chain optimization tool known as WIT (Watson Implosion Technology). Using the WIT tool, we were able to determine a theoretical optimal cost scenario for PTB programs. The study was designed to assist IBM internally in determining theoretical optimal Product Take Back program models and determining potential incentives for increasing participation rates.

  9. Effect of battery longevity on costs and health outcomes associated with cardiac implantable electronic devices: a Markov model-based Monte Carlo simulation.

    PubMed

    Schmier, Jordana K; Lau, Edmund C; Patel, Jasmine D; Klenk, Juergen A; Greenspon, Arnold J

    2017-11-01

    The effects of device and patient characteristics on health and economic outcomes in patients with cardiac implantable electronic devices (CIEDs) are unclear. Modeling can estimate costs and outcomes for patients with CIEDs under a variety of scenarios, varying battery longevity, comorbidities, and care settings. The objective of this analysis was to compare changes in patient outcomes and payer costs attributable to increases in battery life of implantable cardiac defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D). We developed a Monte Carlo Markov model simulation to follow patients through primary implant, postoperative maintenance, generator replacement, and revision states. Patients were simulated in 3-month increments for 15 years or until death. Key variables included Charlson Comorbidity Index, CIED type, legacy versus extended battery longevity, mortality rates (procedure and all-cause), infection and non-infectious complication rates, and care settings. Costs included procedure-related (facility and professional), maintenance, and infections and non-infectious complications, all derived from Medicare data (2004-2014, 5% sample). Outcomes included counts of battery replacements, revisions, infections and non-infectious complications, and discounted (3%) costs and life years. An increase in battery longevity in ICDs yielded reductions in numbers of revisions (by 23%), battery changes (by 44%), infections (by 23%), non-infectious complications (by 10%), and total costs per patient (by 9%). Analogous reductions for CRT-Ds were 23% (revisions), 32% (battery changes), 22% (infections), 8% (complications), and 10% (costs). Based on modeling results, as battery longevity increases, patients experience fewer adverse outcomes and healthcare costs are reduced. Understanding the magnitude of the cost benefit of extended battery life can inform budgeting and planning decisions by healthcare providers and insurers.

  10. Getting started with electronic mail.

    PubMed Central

    Van Vuren, D D; Johnson, D E

    1985-01-01

    This paper gives suggestions to librarians on how to get started with electronic mail. It discusses the cost- and time-saving advantages of using electronic mail rather than TWX, United States mail, or telephones for communicating ILL requests and messages. For instance, preliminary cost data show that electronic mail is often half as expensive as TWX and costs no more than a 22 stamp. Key management concerns that must be considered when setting up electronic mail are discussed, including the need for subscribers to agree on one system. Also covered are the types of equipment that can be used with electronic mail, including print terminals. PMID:4027444

  11. Personal electronics printing via tapping mode composite liquid metal ink delivery and adhesion mechanism

    NASA Astrophysics Data System (ADS)

    Zheng, Yi; He, Zhi-Zhu; Yang, Jun; Liu, Jing

    2014-04-01

    Printed electronics is becoming increasingly important in a variety of newly emerging areas. However, restricted to the rather limited conductive inks and available printing strategies, the current electronics manufacture is usually confined to industry level. Here, we show a highly cost-effective and entirely automatic printing way towards personal electronics making, through introducing a tapping-mode composite fluid delivery system. Fundamental mechanisms regarding the reliable printing, transfer and adhesion of the liquid metal inks on the substrate were disclosed through systematic theoretical interpretation and experimental measurements. With this liquid metal printer, a series of representative electronic patterns spanning from single wires to desired complex configurations such as integrated circuit (IC), printed-circuits-on-board (PCB), electronic paintings, or more do-it-yourself (DIY) devices, were demonstrated to be printed out with high precision in a moment. And the total machine cost already reached personally affordable price. This is hard to achieve by a conventional PCB technology which generally takes long time and is material, water and energy consuming, while the existing printed electronics is still far away from the real direct printing goal. The present work opens the way for large scale personal electronics manufacture and is expected to generate important value for the coming society.

  12. Personal electronics printing via tapping mode composite liquid metal ink delivery and adhesion mechanism.

    PubMed

    Zheng, Yi; He, Zhi-Zhu; Yang, Jun; Liu, Jing

    2014-04-04

    Printed electronics is becoming increasingly important in a variety of newly emerging areas. However, restricted to the rather limited conductive inks and available printing strategies, the current electronics manufacture is usually confined to industry level. Here, we show a highly cost-effective and entirely automatic printing way towards personal electronics making, through introducing a tapping-mode composite fluid delivery system. Fundamental mechanisms regarding the reliable printing, transfer and adhesion of the liquid metal inks on the substrate were disclosed through systematic theoretical interpretation and experimental measurements. With this liquid metal printer, a series of representative electronic patterns spanning from single wires to desired complex configurations such as integrated circuit (IC), printed-circuits-on-board (PCB), electronic paintings, or more do-it-yourself (DIY) devices, were demonstrated to be printed out with high precision in a moment. And the total machine cost already reached personally affordable price. This is hard to achieve by a conventional PCB technology which generally takes long time and is material, water and energy consuming, while the existing printed electronics is still far away from the real direct printing goal. The present work opens the way for large scale personal electronics manufacture and is expected to generate important value for the coming society.

  13. Personal electronics printing via tapping mode composite liquid metal ink delivery and adhesion mechanism

    PubMed Central

    Zheng, Yi; He, Zhi-Zhu; Yang, Jun; Liu, Jing

    2014-01-01

    Printed electronics is becoming increasingly important in a variety of newly emerging areas. However, restricted to the rather limited conductive inks and available printing strategies, the current electronics manufacture is usually confined to industry level. Here, we show a highly cost-effective and entirely automatic printing way towards personal electronics making, through introducing a tapping-mode composite fluid delivery system. Fundamental mechanisms regarding the reliable printing, transfer and adhesion of the liquid metal inks on the substrate were disclosed through systematic theoretical interpretation and experimental measurements. With this liquid metal printer, a series of representative electronic patterns spanning from single wires to desired complex configurations such as integrated circuit (IC), printed-circuits-on-board (PCB), electronic paintings, or more do-it-yourself (DIY) devices, were demonstrated to be printed out with high precision in a moment. And the total machine cost already reached personally affordable price. This is hard to achieve by a conventional PCB technology which generally takes long time and is material, water and energy consuming, while the existing printed electronics is still far away from the real direct printing goal. The present work opens the way for large scale personal electronics manufacture and is expected to generate important value for the coming society. PMID:24699375

  14. Virtual enterprise model for the electronic components business in the Nuclear Weapons Complex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferguson, T.J.; Long, K.S.; Sayre, J.A.

    1994-08-01

    The electronic components business within the Nuclear Weapons Complex spans organizational and Department of Energy contractor boundaries. An assessment of the current processes indicates a need for fundamentally changing the way electronic components are developed, procured, and manufactured. A model is provided based on a virtual enterprise that recognizes distinctive competencies within the Nuclear Weapons Complex and at the vendors. The model incorporates changes that reduce component delivery cycle time and improve cost effectiveness while delivering components of the appropriate quality.

  15. Costing the distribution of insecticide-treated nets: a review of cost and cost-effectiveness studies to provide guidance on standardization of costing methodology.

    PubMed

    Kolaczinski, Jan; Hanson, Kara

    2006-05-08

    Insecticide-treated nets (ITNs) are an effective and cost-effective means of malaria control. Scaling-up coverage of ITNs is challenging. It requires substantial resources and there are a number of strategies to choose from. Information on the cost of different strategies is still scarce. To guide the choice of a delivery strategy (or combination of strategies), reliable and standardized cost information for the different options is required. The electronic online database PubMed was used for a systematic search of the published English literature on costing and economic evaluations of ITN distribution programmes. The keywords used were: net, bednet, insecticide, treated, ITN, cost, effectiveness, economic and evaluation. Identified papers were analysed to determine and evaluate the costing methods used. Methods were judged against existing standards of cost analysis to arrive at proposed standards for undertaking and presenting cost analyses. Cost estimates were often not readily comparable or could not be adjusted to a different context. This resulted from the wide range of methods applied and measures of output chosen. Most common shortcomings were the omission of certain costs and failure to adjust financial costs to generate economic costs. Generalisability was hampered by authors not reporting quantities and prices of resources separately and not examining the sensitivity of their results to variations in underlying assumptions. The observed shortcomings have arisen despite the abundance of literature and guidelines on costing of health care interventions. This paper provides ITN specific recommendations in the hope that these will help to standardize future cost estimates.

  16. Keeping the Dialogue Flowing.

    ERIC Educational Resources Information Center

    Kennedy, Susan

    2001-01-01

    Discusses the need for complete communication between all interested parties to successfully build or renovate school restrooms. How the use of electronics can help restroom retrofits to be more cost effective and enhance conservation is highlighted. (GR)

  17. Electron Beam Cured Epoxy Resin Composites for High Temperature Applications

    NASA Technical Reports Server (NTRS)

    Janke, Christopher J.; Dorsey, George F.; Havens, Stephen J.; Lopata, Vincent J.; Meador, Michael A.

    1997-01-01

    Electron beam curing of Polymer Matrix Composites (PMC's) is a nonthermal, nonautoclave curing process that has been demonstrated to be a cost effective and advantageous alternative to conventional thermal curing. Advantages of electron beam curing include: reduced manufacturing costs; significantly reduced curing times; improvements in part quality and performance; reduced environmental and health concerns; and improvement in material handling. In 1994 a Cooperative Research and Development Agreement (CRADA), sponsored by the Department of Energy Defense Programs and 10 industrial partners, was established to advance the electron beam curing of PMC technology. Over the last several years a significant amount of effort within the CRADA has been devoted to the development and optimization of resin systems and PMCs that match the performance of thermal cured composites. This highly successful materials development effort has resulted in a board family of high performance, electron beam curable cationic epoxy resin systems possessing a wide range of excellent processing and property profiles. Hundreds of resin systems, both toughened and untoughened, offering unlimited formulation and processing flexibility have been developed and evaluated in the CRADA program.

  18. Back-bombardment compensation in microwave thermionic electron guns

    NASA Astrophysics Data System (ADS)

    Kowalczyk, Jeremy M. D.; Madey, John M. J.

    2014-12-01

    The development of capable, reliable, and cost-effective compact electron beam sources remains a long-standing objective of the efforts to develop the accelerator systems needed for on-site research and industrial applications ranging from electron beam welding to high performance x-ray and gamma ray light sources for element-resolved microanalysis and national security. The need in these applications for simplicity, reliability, and low cost has emphasized solutions compatible with the use of the long established and commercially available pulsed microwave rf sources and L-, S- or X-band linear accelerators. Thermionic microwave electron guns have proven to be one successful approach to the development of the electron sources for these systems providing high macropulse average current beams with picosecond pulse lengths and good emittance out to macropulse lengths of 4-5 microseconds. But longer macropulse lengths are now needed for use in inverse-Compton x-ray sources and other emerging applications. We describe in this paper our approach to extending the usable macropulse current and pulse length of these guns through the use of thermal diffusion to compensate for the increase in cathode surface temperature due to back-bombardment.

  19. Integrated Nationwide Electronic Health Records system: Semi-distributed architecture approach.

    PubMed

    Fragidis, Leonidas L; Chatzoglou, Prodromos D; Aggelidis, Vassilios P

    2016-11-14

    The integration of heterogeneous electronic health records systems by building an interoperable nationwide electronic health record system provides undisputable benefits in health care, like superior health information quality, medical errors prevention and cost saving. This paper proposes a semi-distributed system architecture approach for an integrated national electronic health record system incorporating the advantages of the two dominant approaches, the centralized architecture and the distributed architecture. The high level design of the main elements for the proposed architecture is provided along with diagrams of execution and operation and data synchronization architecture for the proposed solution. The proposed approach effectively handles issues related to redundancy, consistency, security, privacy, availability, load balancing, maintainability, complexity and interoperability of citizen's health data. The proposed semi-distributed architecture offers a robust interoperability framework without healthcare providers to change their local EHR systems. It is a pragmatic approach taking into account the characteristics of the Greek national healthcare system along with the national public administration data communication network infrastructure, for achieving EHR integration with acceptable implementation cost.

  20. SPATIAL PATTERNS OF WATER QUALITY AND PLANKTON FROM HIGH-RESOLUTION CONTINUOUS IN SITU SENSING ALONG A 537-KM NEARSHORE TRANSECT OF WESTERN LAKE SUPERIOR, 2004

    EPA Science Inventory

    A demonstration that the adaptation of electronic instrumentation and towed survey strategies are effective in providing rapid, spatially extensive, and cost effective data for assessment of the Great Lakes.

  1. A 20-liter test stand with gas purification for liquid argon research

    DOE PAGES

    Li, Y.; Thorn, C.; Tang, W.; ...

    2016-06-06

    Here, we describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). Moreover, this system utilizes a simple, cost-effective gas argon (GAr) purification to achieve high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. Finally, a gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.

  2. A 20-liter test stand with gas purification for liquid argon research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y.; Thorn, C.; Tang, W.

    Here, we describe the design of a 20-liter test stand constructed to study fundamental properties of liquid argon (LAr). Moreover, this system utilizes a simple, cost-effective gas argon (GAr) purification to achieve high purity, which is necessary to study electron transport properties in LAr. An electron drift stack with up to 25 cm length is constructed to study electron drift, diffusion, and attachment at various electric fields. Finally, a gold photocathode and a pulsed laser are used as a bright electron source. The operational performance of this system is reported.

  3. Clinician-patient E-mail communication: challenges for reimbursement.

    PubMed

    Komives, Eugenie M

    2005-01-01

    Clinicians are rapidly gaining experience with online clinician-patient consultation, and more tools are becoming available to support these efforts. In addition, we now have evidence that using electronic communication is cost-effective to payers and appealing to patients and providers. At present, there appear to be few barriers to the adoption of these solutions for practices that use other online services. Security concerns can easily be overcome by using programs described in this commentary. Larger and longer studies that evaluate the benefits and cost savings in more detail may help convince other payers and providers of the utility of the Web-based programs. More studies are needed to understand the effect of dinician-patient electronic communication on the costs of caring for chronic illness. When these solutions also include support tools, such as electronic prescribing, which could improve patient safety and quality of care, they should be encouraged. In their article entitled, "Electrons in Flight-Email between Doctors and Patients," Delbanco and Sands postulate that the future of e-communication in medicine will be integrated with a patient-controlled health record and will include secure synchronous and asynchronous communication, video conferencing and messaging, instant transcription into the written record, full-patient access to the record, translation into different languages, connectivity to multiple data sources, incorporation of multi-media educational materials. It-will also allow data from home-based diagnostic technology to be sent to clinicians. "Electronic communication will move medicine inexorably toward such transparency, enabling doctors and patients to share knowledge, responsibility, and decision-making more equally. We need to explore rapidly how this change will affect the quality of care for patients and the quality of life for doctors." The widespread dependence on Internet-based electronic communication to support a variety of commercial, educational, and entertainment needs and interests offers us an opportunity to develop innovative approaches to some long-standing problems-assuring the accessibility of clinicians to their patients and the effectiveness and timeliness of communication between them. It is exciting that we now have well-documented examples of how these new technologies can be used to enhance the quality of primary care practice in both large and small practice organizations.

  4. Impact of Internally Developed Electronic Prescription on Prescribing Errors at Discharge from the Emergency Department

    PubMed Central

    Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif

    2017-01-01

    Introduction Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%–38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. Methods We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Results Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p <0.0001), missing frequency (3.5% to 2.2%, p=0.04), missing strength errors (32.4% to 10.2%, p <0.0001) and legibility (0.7% to 0.2%, p=0.005). E-prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). Conclusion A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive. PMID:28874948

  5. Impact of Internally Developed Electronic Prescription on Prescribing Errors at Discharge from the Emergency Department.

    PubMed

    Hitti, Eveline; Tamim, Hani; Bakhti, Rinad; Zebian, Dina; Mufarrij, Afif

    2017-08-01

    Medication errors are common, with studies reporting at least one error per patient encounter. At hospital discharge, medication errors vary from 15%-38%. However, studies assessing the effect of an internally developed electronic (E)-prescription system at discharge from an emergency department (ED) are comparatively minimal. Additionally, commercially available electronic solutions are cost-prohibitive in many resource-limited settings. We assessed the impact of introducing an internally developed, low-cost E-prescription system, with a list of commonly prescribed medications, on prescription error rates at discharge from the ED, compared to handwritten prescriptions. We conducted a pre- and post-intervention study comparing error rates in a randomly selected sample of discharge prescriptions (handwritten versus electronic) five months pre and four months post the introduction of the E-prescription. The internally developed, E-prescription system included a list of 166 commonly prescribed medications with the generic name, strength, dose, frequency and duration. We included a total of 2,883 prescriptions in this study: 1,475 in the pre-intervention phase were handwritten (HW) and 1,408 in the post-intervention phase were electronic. We calculated rates of 14 different errors and compared them between the pre- and post-intervention period. Overall, E-prescriptions included fewer prescription errors as compared to HW-prescriptions. Specifically, E-prescriptions reduced missing dose (11.3% to 4.3%, p <0.0001), missing frequency (3.5% to 2.2%, p=0.04), missing strength errors (32.4% to 10.2%, p <0.0001) and legibility (0.7% to 0.2%, p=0.005). E-prescriptions, however, were associated with a significant increase in duplication errors, specifically with home medication (1.7% to 3%, p=0.02). A basic, internally developed E-prescription system, featuring commonly used medications, effectively reduced medication errors in a low-resource setting where the costs of sophisticated commercial electronic solutions are prohibitive.

  6. A cost-effectiveness analysis of online, radio and print tobacco control advertisements targeting 25-39 year-old males.

    PubMed

    Clayforth, Cassandra; Pettigrew, Simone; Mooney, Katie; Lansdorp-Vogelaar, Iris; Rosenberg, Michael; Slevin, Terry

    2014-06-01

    To assess the relative cost-effectiveness of various non-television advertising media in encouraging 25-39 year-old male smokers to respond to a cessation-related call to action. Information about how new electronic media compare in effectiveness is important to inform the implementation of future tobacco control media campaigns. Two testimonial advertisements featuring members of the target group were developed for radio, press and online media. Multiple waves of media activity were scheduled over a period of seven weeks, including an initial integrated period that included all three media and subsequent single media phases that were interspersed with a week of no media activity. The resulting Quit website hits, Quitline telephone calls, and registrations to online and telephone counselling services were compared to advertising costs to determine the relative cost-effectiveness of each media in isolation and the integrated approach. The online-only campaign phase was substantially more cost-effective than the other phases, including the integrated approach. This finding is contrary to the current assumption that the use of a consistent message across multiple media simultaneously is the most cost-effective way of reaching and affecting target audiences. Online advertising may be a highly cost-effective channel for low-budget tobacco control media campaigns. © 2014 The Authors. ANZJPH © 2014 Public Health Association of Australia.

  7. Automotive displays and controls : existing technology and future trends

    DOT National Transportation Integrated Search

    1987-11-01

    This report presents overview information on high-technology displays and : controls that are having a substantial effect on the driving environment. Advances : in electronics and computers, in addition to cost advantages, increase the : technologies...

  8. Implementing electronic identification for performance recording in sheep: II. Cost-benefit analysis in meat and dairy farms.

    PubMed

    Ait-Saidi, A; Caja, G; Salama, A A K; Milán, M J

    2014-12-01

    Costs and secondary benefits of implementing electronic identification (e-ID) for performance recording (i.e., lambing, body weight, inventory, and milk yield) in dairy and meat ewes were assessed by using the results from a previous study in which manual (M), semiautomatic (SA), and automatic (AU) data collection systems were compared. Ewes were identified with visual ear tags and electronic rumen boluses. The M system used visual identification, on-paper data recording, and manual data uploading to a computer. The SA system used e-ID with a handheld reader in which performances were typed and automatic uploaded to a computer. The use of a personal digital assistant (PDA) for recording and automatic data uploading, which transformed M in a SA system, was also considered. The AU system was only used for BW recording and consisted of e-ID, automatic data recording in an electronic scale, and uploading to a computer. The cost-benefit study was applied to 2 reference sheep farms of 700 meat ewes, under extensive or intensive production systems, and of 400 dairy ewes, practicing once- or twice-a-day machine milkings. Sensitivity analyses under voluntary and mandatory e-ID scenarios were also included. Benefits of using e-ID for SA or AU performance recording mainly depended on sheep farm purpose, number of test days per year, handheld reader and PDA prices, and flock size. Implementing e-ID for SA and AU performance recording saved approximately 50% of the time required by the M system, and increased the reliability of the data collected. Use of e-ID increased the cost of performance recording in a voluntary e-ID scenario, paying only partially the investment made (15 to 70%). For the mandatory e-ID scenario, in which the cost of e-ID devices was not included, savings paid 100% of the extra costs needed for using e-ID in all farm types and conditions. In both scenarios, the reader price was the most important extra cost (40 to 90%) for implementing e-ID in sheep farms. Calculated extra costs of using the PDA covered more than 100% of the implementation costs in all type of sheep farms, indicating that this device was cost-effective for sheep-performance recording. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. The opportunities for and challenges of common integrated electronics

    NASA Astrophysics Data System (ADS)

    Nelson, J. R.; Retterer, Bernard L.; Cloud, Harley A.

    1994-02-01

    This document summarizes a portion of IDA's work concerning common integrated electronics and the potential cost savings of using common electronic hardware and software. It addresses trends in avionics costs and recent experiences in applying common electronic standards to weapon programs as a way to reduce costs. The following essential elements of a program to acquire common integrated electronics are explored: (1) integrated system architecture; (2) advanced technology programs; (3) open system standards; (4) standard common modules; and (5) associated management and policies. The principal recommendation is that OSD support and coordinate such a-program by taking a strong leadership role and setting standards policy.

  10. Working with Allies and Partners: A Cost-Based Analysis of U.S. Air Forces in Europe

    DTIC Science & Technology

    2012-01-01

    Reports & Bookstore Make a charitable contribution Limited Electronic Distribution Rights This document and trademark(s) contained herein are protected by...67 A.13. The Effect ...That Building Partnerships and Partner Capacity Can Have on the Ability to Work Effectively with Partner Countries

  11. Tips and Tools for Creating eNewsletters

    ERIC Educational Resources Information Center

    Walker, Tim

    2006-01-01

    An electronic newsletter, or "eNewsletter" for short, is a cost-effective informational publication typically distributed weekly or monthly using e-mail. If properly implemented, it can become an effective customer service tool, providing an opportunity to share information with children, parents, and families. It can also serve as a powerful…

  12. Low-Cost Oil Quality Sensor Based on Changes in Complex Permittivity

    PubMed Central

    Pérez, Angel Torres; Hadfield, Mark

    2011-01-01

    Real time oil quality monitoring techniques help to protect important industry assets, minimize downtime and reduce maintenance costs. The measurement of a lubricant’s complex permittivity is an effective indicator of the oil degradation process and it can be useful in condition based maintenance (CBM) to select the most adequate oil replacement maintenance schedules. A discussion of the working principles of an oil quality sensor based on a marginal oscillator to monitor the losses of the dielectric at high frequencies (>1 MHz) is presented. An electronic design procedure is covered which results in a low cost, effective and ruggedized sensor implementation suitable for use in harsh environments. PMID:22346666

  13. Ab initio molecular dynamics with nuclear quantum effects at classical cost: Ring polymer contraction for density functional theory.

    PubMed

    Marsalek, Ondrej; Markland, Thomas E

    2016-02-07

    Path integral molecular dynamics simulations, combined with an ab initio evaluation of interactions using electronic structure theory, incorporate the quantum mechanical nature of both the electrons and nuclei, which are essential to accurately describe systems containing light nuclei. However, path integral simulations have traditionally required a computational cost around two orders of magnitude greater than treating the nuclei classically, making them prohibitively costly for most applications. Here we show that the cost of path integral simulations can be dramatically reduced by extending our ring polymer contraction approach to ab initio molecular dynamics simulations. By using density functional tight binding as a reference system, we show that our ring polymer contraction scheme gives rapid and systematic convergence to the full path integral density functional theory result. We demonstrate the efficiency of this approach in ab initio simulations of liquid water and the reactive protonated and deprotonated water dimer systems. We find that the vast majority of the nuclear quantum effects are accurately captured using contraction to just the ring polymer centroid, which requires the same number of density functional theory calculations as a classical simulation. Combined with a multiple time step scheme using the same reference system, which allows the time step to be increased, this approach is as fast as a typical classical ab initio molecular dynamics simulation and 35× faster than a full path integral calculation, while still exactly including the quantum sampling of nuclei. This development thus offers a route to routinely include nuclear quantum effects in ab initio molecular dynamics simulations at negligible computational cost.

  14. Utility values associated with advanced or metastatic non-small cell lung cancer: data needs for economic modeling.

    PubMed

    Brown, Jacqueline; Cook, Keziah; Adamski, Kelly; Lau, Jocelyn; Bargo, Danielle; Breen, Sarah; Chawla, Anita

    2017-04-01

    Cost-effectiveness analyses often inform healthcare reimbursement decisions. The preferred measure of effectiveness is the quality adjusted life year (QALY) gained, where the quality of life adjustment is measured in terms of utility. Areas covered: We assessed the availability and variation of utility values for health states associated with advanced or metastatic non-small cell lung cancer (NSCLC) to identify values appropriate for cost-effectiveness models assessing alternative treatments. Our systematic search of six electronic databases (January 2000 to August 2015) found the current literature to be sparse in terms of utility values associated with NSCLC, identifying 27 studies. Utility values were most frequently reported over time and by treatment type, and less frequently by disease response, stage of disease, adverse events or disease comorbidities. Expert commentary: In response to rising healthcare costs, payers increasingly consider the cost-effectiveness of novel treatments in reimbursement decisions, especially in oncology. As the number of therapies available to treat NSCLC increases, cost-effectiveness analyses will play a key role in reimbursement decisions in this area. Quantifying the relationship between health and quality of life for NSCLC patients via utility values is an important component of assessing the cost effectiveness of novel treatments.

  15. A Systematic Literature Review of Economic Evaluations of Antibiotic Treatments for Clostridium difficile Infection.

    PubMed

    Burton, Hannah E; Mitchell, Stephen A; Watt, Maureen

    2017-11-01

    Clostridium difficile infection (CDI) is associated with high management costs, particularly in recurrent cases. Fidaxomicin treatment results in lower recurrence rates than vancomycin and metronidazole, but has higher acquisition costs in Europe and the USA. This systematic literature review summarises economic evaluations (EEs) of fidaxomicin, vancomycin and metronidazole for treatment of CDI. Electronic databases (MEDLINE ® , Embase, Cochrane Library) and conference proceedings (ISPOR, ECCMID, ICAAC and IDWeek) were searched for publications reporting EEs of fidaxomicin, vancomycin and/or metronidazole in the treatment of CDI. Reference bibliographies of identified manuscripts were also reviewed. Cost-effectiveness was evaluated according to the overall population of patients with CDI, as well as in subgroups with severe CDI or recurrent CDI, or those at higher risk of recurrence or mortality. Overall, 27 relevant EEs, conducted from the perspective of 12 different countries, were identified. Fidaxomicin was cost-effective versus vancomycin and/or metronidazole in 14 of 24 EEs (58.3%), vancomycin was cost-effective versus fidaxomicin and/or metronidazole in five of 27 EEs (18.5%) and metronidazole was cost-effective versus fidaxomicin and/or vancomycin in two of 13 EEs (15.4%). Fidaxomicin was cost-effective versus vancomycin in most of the EEs evaluating specific patient subgroups. Key cost-effectiveness drivers were cure rate, recurrence rate, time horizon, drug costs and length and cost of hospitalisation. In most EEs, fidaxomicin was demonstrated to be cost-effective versus metronidazole and vancomycin in patients with CDI. These results have relevance to clinical practice, given the high budgetary impact of managing CDI and increasing restrictions on healthcare budgets. This analysis was initiated and funded by Astellas Pharma Inc.

  16. Costing the distribution of insecticide-treated nets: a review of cost and cost-effectiveness studies to provide guidance on standardization of costing methodology

    PubMed Central

    Kolaczinski, Jan; Hanson, Kara

    2006-01-01

    Background Insecticide-treated nets (ITNs) are an effective and cost-effective means of malaria control. Scaling-up coverage of ITNs is challenging. It requires substantial resources and there are a number of strategies to choose from. Information on the cost of different strategies is still scarce. To guide the choice of a delivery strategy (or combination of strategies), reliable and standardized cost information for the different options is required. Methods The electronic online database PubMed was used for a systematic search of the published English literature on costing and economic evaluations of ITN distribution programmes. The keywords used were: net, bednet, insecticide, treated, ITN, cost, effectiveness, economic and evaluation. Identified papers were analysed to determine and evaluate the costing methods used. Methods were judged against existing standards of cost analysis to arrive at proposed standards for undertaking and presenting cost analyses. Results Cost estimates were often not readily comparable or could not be adjusted to a different context. This resulted from the wide range of methods applied and measures of output chosen. Most common shortcomings were the omission of certain costs and failure to adjust financial costs to generate economic costs. Generalisability was hampered by authors not reporting quantities and prices of resources separately and not examining the sensitivity of their results to variations in underlying assumptions. Conclusion The observed shortcomings have arisen despite the abundance of literature and guidelines on costing of health care interventions. This paper provides ITN specific recommendations in the hope that these will help to standardize future cost estimates. PMID:16681856

  17. Attitudes on cost-effectiveness and equity: a cross-sectional study examining the viewpoints of medical professionals

    PubMed Central

    Li, David G; Wong, Gordon X; Martin, David T; Tybor, David J; Kim, Jennifer; Lasker, Jeffrey; Mitty, Roger; Salem, Deeb

    2017-01-01

    Objective To determine the attitudes of physicians and trainees in regard to the roles of both cost-effectiveness and equity in clinical decision making. Design In this cross-sectional study, electronic surveys containing a hypothetical decision-making scenario were sent to medical professionals to select between two colon cancer screening tests for a population. Setting Three Greater Boston academic medical institutions: Tufts University School of Medicine, Tufts Medical Centre and Lahey Hospital and Medical Centre. Participants 819 medical students, 497 residents-in-training and 671 practising physicians were contacted electronically using institutional and organisational directories. Main outcome(s) and measure(s) Stratified opinions of medical providers and trainee subgroups regarding cost-effectiveness and equity. Results A total of 881 respondents comprising 512 medical students, 133 medical residents-in-training and 236 practising physicians completed the survey (total response rate 44.3%). Thirty-six per cent of medical students, 44% of residents-in-training and 53% of practising physicians favoured the less effective and more equitable screening test. Residents-in-training (OR 1.49, CI 1.01 to 2.21; p=0.044) and practising physicians (OR 2.12, CI 1.54 to 2.92; p<0.001) were more likely to favour the equitable option compared with medical students. Moreover, female responders across all three cohorts favoured the more equitable screening test to a greater degree than did male responders (OR 1.70, CI 1.29 to 2.24; p<0.001). Conclusions Cost-effectiveness analysis does not accurately reflect the importance that medical professionals place on equity. Among medical professionals, practising physicians appear to be more egalitarian than residents-in-training, while medical students appear to be most utilitarian and cost-effective. Meanwhile, female respondents in all three cohorts favoured the more equitable option to a greater degree than their male counterparts. Healthcare policies that trade off equity in favour of cost-effectiveness may be unacceptable to many medical professionals, especially practising physicians and women. PMID:28765138

  18. Attitudes on cost-effectiveness and equity: a cross-sectional study examining the viewpoints of medical professionals.

    PubMed

    Li, David G; Wong, Gordon X; Martin, David T; Tybor, David J; Kim, Jennifer; Lasker, Jeffrey; Mitty, Roger; Salem, Deeb

    2017-08-01

    To determine the attitudes of physicians and trainees in regard to the roles of both cost-effectiveness and equity in clinical decision making. In this cross-sectional study, electronic surveys containing a hypothetical decision-making scenario were sent to medical professionals to select between two colon cancer screening tests for a population. Three Greater Boston academic medical institutions: Tufts University School of Medicine, Tufts Medical Centre and Lahey Hospital and Medical Centre. 819 medical students, 497 residents-in-training and 671 practising physicians were contacted electronically using institutional and organisational directories. Stratified opinions of medical providers and trainee subgroups regarding cost-effectiveness and equity. A total of 881 respondents comprising 512 medical students, 133 medical residents-in-training and 236 practising physicians completed the survey (total response rate 44.3%). Thirty-six per cent of medical students, 44% of residents-in-training and 53% of practising physicians favoured the less effective and more equitable screening test. Residents-in-training (OR 1.49, CI 1.01 to 2.21; p=0.044) and practising physicians (OR 2.12, CI 1.54 to 2.92; p<0.001) were more likely to favour the equitable option compared with medical students. Moreover, female responders across all three cohorts favoured the more equitable screening test to a greater degree than did male responders (OR 1.70, CI 1.29 to 2.24; p<0.001). Cost-effectiveness analysis does not accurately reflect the importance that medical professionals place on equity. Among medical professionals, practising physicians appear to be more egalitarian than residents-in-training, while medical students appear to be most utilitarian and cost-effective. Meanwhile, female respondents in all three cohorts favoured the more equitable option to a greater degree than their male counterparts. Healthcare policies that trade off equity in favour of cost-effectiveness may be unacceptable to many medical professionals, especially practising physicians and women. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. An Economic Evaluation of Colorectal Cancer Screening in Primary Care Practice

    PubMed Central

    Meenan, Richard T.; Anderson, Melissa L.; Chubak, Jessica; Vernon, Sally W.; Fuller, Sharon; Wang, Ching-Yun; Green, Beverly B.

    2015-01-01

    Introduction Recent colorectal cancer screening studies focus on optimizing adherence. This study evaluated the cost effectiveness of interventions using electronic health records (EHRs), automated mailings, and stepped support increases to improve 2-year colorectal cancer screening adherence. Methods Analyses were based on a parallel-design, randomized trial in which three stepped interventions (EHR-linked mailings [“automated”], automated plus telephone assistance [“assisted”], or automated and assisted plus nurse navigation to testing completion or refusal [navigated”]) were compared to usual care. Data were from August 2008–November 2011 with analyses performed during 2012–2013. Implementation resources were micro-costed; research and registry development costs were excluded. Incremental cost-effectiveness ratios (ICERs) were based on number of participants current for screening per guidelines over 2 years. Bootstrapping examined robustness of results. Results Intervention delivery cost per participant current for screening ranged from $21 (automated) to $27 (navigated). Inclusion of induced testing costs (e.g., screening colonoscopy) lowered expenditures for automated (ICER=−$159) and assisted (ICER=−$36) relative to usual care over 2 years. Savings arose from increased fecal occult blood testing, substituting for more expensive colonoscopies in usual care. Results were broadly consistent across demographic subgroups. More intensive interventions were consistently likely to be cost effective relative to less intensive interventions, with willingness to pay values of $600–$1,200 for an additional person current for screening yielding ≥80% probability of cost effectiveness. Conclusions Two-year cost effectiveness of a stepped approach to colorectal cancer screening promotion based on EHR data is indicated, but longer-term cost effectiveness requires further study. PMID:25998922

  20. Cost-effectiveness of exercise therapy in the treatment of non-specific neck pain and low back pain: a systematic review with meta-analysis.

    PubMed

    Miyamoto, Gisela Cristiane; Lin, Chung-Wei Christine; Cabral, Cristina Maria Nunes; van Dongen, Johanna M; van Tulder, Maurits W

    2018-04-20

    To investigate the cost-effectiveness of exercise therapy in the treatment of patients with non-specific neck pain and low back pain. Systematic review of economic evaluations. The search was performed in 5 clinical and 3 economic electronic databases. We included economic evaluations performed alongside randomised controlled trials. Differences in costs and effects were pooled in a meta-analysis, if possible, and incremental cost-utility ratios (ICUR) were descriptively analysed. Twenty-two studies were included. On average, exercise therapy was associated with lower costs and larger effects for quality-adjusted life-year (QALY) in comparison with usual care for subacute and chronic low back pain from a healthcare perspective (based on ICUR). Exercise therapy had similar costs and effect for QALY in comparison with other interventions for neck pain from a societal perspective, and subacute and chronic low back pain from a healthcare perspective. There was limited or inconsistent evidence on the cost-effectiveness of exercise therapy compared with usual care for neck pain and acute low back pain, other interventions for acute low back pain and different types of exercise therapy for neck pain and low back pain. Exercise therapy seems to be cost-effective compared with usual care for subacute and chronic low back pain. Exercise therapy was not (more) cost-effective compared with other interventions for neck pain and low back pain. The cost-utility estimates are rather uncertain, indicating that more economic evaluations are needed. PROSPERO, CRD42017059025. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Economic impact of routine opt-out antenatal human immune deficiency virus screening: A systematic review.

    PubMed

    Ibekwe, Everistus; Haigh, Carol; Duncan, Fiona; Fatoye, Francis

    2017-12-01

    To evaluate the economic impact of routine testing of human immune deficiency virus in antenatal settings. Many children are being infected with human immune deficiency virus through mother-to-child transmission of the virus. Most of these infections are preventable if the mothers' human immune deficiency virus status is identified in a timely manner and appropriate interventions put in place. Routine human immune deficiency virus testing is widely acclaimed as a strategy for universal access to human immune deficiency virus testing and is being adopted by developed and developing poor income countries without recourse to the economic impact. A systematic review of published articles. Extensive electronic searches for relevant journal articles published from 1998-2015 when countries began to implement routine antenatal HIV testing on their own were conducted in the following databases: Science Direct, MEDLINE, SCOPUS, JSTOR, CINAHL and PubMed with search terms as listed in Box 2. Manual searches were also performed to complement the electronic identification of high-quality materials. There were no geographical restrictions, but language was limited to English. Fifty-five articles were retrieved; however, ten were eligible and included in the review. The findings showed that many programmes involving routine human immune deficiency virus testing for pregnant women compared to the alternatives were cost-effective and cost saving. Data from the reviewed studies showed cost savings between $5,761.20-$3.69 million per case of previously undiagnosed maternal human immune deficiency virus-positive infection prevented. Overall, cost-effectiveness was strongly associated with the prevalence rate of human immune deficiency virus in the various settings. Routine human immune deficiency virus testing is both cost-effective and cost saving compared to the alternatives. However, there are wide variations in the methodological approaches to the studies. Adopting standard reporting format would facilitate comparison between studies and generalisability of economic evaluations. (i) Healthcare decision-makers should understand that routine antenatal screening for human immune deficiency virus is both cost-effective and cost saving. (ii) Addressing late identification of prenatal human immune deficiency virus is crucial to reducing mother-to-child transmission at minimal healthcare spending. © 2017 John Wiley & Sons Ltd.

  2. SAIL: automating interlibrary loan.

    PubMed Central

    Lacroix, E M

    1994-01-01

    The National Library of Medicine (NLM) initiated the System for Automated Interlibrary Loan (SAIL) pilot project to study the feasibility of using imaging technology linked to the DOCLINE system to deliver copies of journal articles. During the project, NLM converted a small number of print journal issues to electronic form, linking the captured articles to the MEDLINE citation unique identifier. DOCLINE requests for these journals that could not be filled by network libraries were routed to SAIL. Nearly 23,000 articles from sixty-four journals recently selected for indexing in Index Medicus were scanned to convert them to electronic images. During fiscal year 1992, 4,586 scanned articles were used to fill 10,444 interlibrary loan (ILL) requests, and more than half of these were used only once. Eighty percent of all the articles were not requested at all. The total cost per article delivered was $10.76, substantially more than it costs to process a photocopy request. Because conversion costs were the major component of the total SAIL cost, and most of the articles captured for the project were not requested, this model was not cost-effective. Data on SAIL journal article use was compared with all ILL requests filled by NLM for the same period. Eighty-eight percent of all articles requested from NLM were requested only once. The results of the SAIL project demonstrated that converting journal articles to electronic images and storing them in anticipation of repeated requests would not meet NLM's objective to improve interlibrary loan. PMID:8004020

  3. SAIL: automating interlibrary loan.

    PubMed

    Lacroix, E M

    1994-04-01

    The National Library of Medicine (NLM) initiated the System for Automated Interlibrary Loan (SAIL) pilot project to study the feasibility of using imaging technology linked to the DOCLINE system to deliver copies of journal articles. During the project, NLM converted a small number of print journal issues to electronic form, linking the captured articles to the MEDLINE citation unique identifier. DOCLINE requests for these journals that could not be filled by network libraries were routed to SAIL. Nearly 23,000 articles from sixty-four journals recently selected for indexing in Index Medicus were scanned to convert them to electronic images. During fiscal year 1992, 4,586 scanned articles were used to fill 10,444 interlibrary loan (ILL) requests, and more than half of these were used only once. Eighty percent of all the articles were not requested at all. The total cost per article delivered was $10.76, substantially more than it costs to process a photocopy request. Because conversion costs were the major component of the total SAIL cost, and most of the articles captured for the project were not requested, this model was not cost-effective. Data on SAIL journal article use was compared with all ILL requests filled by NLM for the same period. Eighty-eight percent of all articles requested from NLM were requested only once. The results of the SAIL project demonstrated that converting journal articles to electronic images and storing them in anticipation of repeated requests would not meet NLM's objective to improve interlibrary loan.

  4. Synthesis of carbon nanospheres using fallen willow leaves and adsorption of Rhodamine B and heavy metals by them.

    PubMed

    Qu, Jiao; Zhang, Qian; Xia, Yunsheng; Cong, Qiao; Luo, Chunqiu

    2015-01-01

    This paper focuses on the synthesis of carbon nanospheres (CNSs) using fallen willow leaves as a low-cost precursor. The scanning electron microscopy (SEM) image and transmission electron microscopy (TEM) image demonstrated that the structure of synthesized CNSs was spherical, with a diameter of 100 nm. The crystal structure and chemical information were characterized by Raman spectrum and energy-dispersive spectrum (EDS), respectively. BET results showed that the CNSs had a larger specific surface area of 294.32 m(2) g(-1), which makes it a potentially superior adsorbent. Rh-B and heavy metal ions such as Cu(2+), Zn(2+), and Cr(6+) were used as targets to investigate the adsorption capacity of the CNSs. The effects of adsorption parameters such as adsorption equilibrium time, dose of CNSs, adsorption kinetics, and effect factors were also studied. These findings not only established a cost-effective method of synthesizing CNSs using fallen willow leaves but also broadened the potential application range of these CNSs.

  5. Recommendations for Establishing Policy for Electronic Prescribing in the State of Texas: Graduate Management Project

    DTIC Science & Technology

    2008-06-24

    of electronic prescribing, but physicians hold concerns that electronic prescribing systems may produce a significant cost burden to their practices...edition number, etc. 14. ABSTRACT. A brief (approximately 200 words) factual summary of the most significant information. 15. SUBJECT TERMS. Key words...in favor of electronic prescribing, but physicians hold concerns that electronic prescribing systems may produce a significant cost burden to their

  6. Challenges for Electronics in the Vision for Space Exploration

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.

    2005-01-01

    This presentation has been a brief snapshot discussing electronics and Exploration-related challenges. The vision for Space Exploration creates a new paradigm for NASA missions. This includes transport (Crew Exploration Vehicle-CEV), and lunar and Mars Exploration and human presence. If one considers the additional hazards faced by these concepts versus more traditional NASA missions, multiple challenges surface for reliable utilization of electronic parts. The true challenge is to provide a risk as low as reasonably achievable (ALARA-a traditional biological radiation exposure term), while still providing cost effective solutions. This presentation also discusses the hazard for electronic parts and exploration, the types of electronic parts for exploration, and the critical juncture for space usage of commercial changes in the electronics world.

  7. Reducing medical claims cost to Ghana's National Health Insurance scheme: a cross-sectional comparative assessment of the paper- and electronic-based claims reviews.

    PubMed

    Nsiah-Boateng, Eric; Asenso-Boadi, Francis; Dsane-Selby, Lydia; Andoh-Adjei, Francis-Xavier; Otoo, Nathaniel; Akweongo, Patricia; Aikins, Moses

    2017-02-06

    A robust medical claims review system is crucial for addressing fraud and abuse and ensuring financial viability of health insurance organisations. This paper assesses claims adjustment rate of the paper- and electronic-based claims reviews of the National Health Insurance Scheme (NHIS) in Ghana. The study was a cross-sectional comparative assessment of paper- and electronic-based claims reviews of the NHIS. Medical claims of subscribers for the year, 2014 were requested from the claims directorate and analysed. Proportions of claims adjusted by the paper- and electronic-based claims reviews were determined for each type of healthcare facility. Bivariate analyses were also conducted to test for differences in claims adjustments between healthcare facility types, and between the two claims reviews. The electronic-based review made overall adjustment of 17.0% from GHS10.09 million (USD2.64 m) claims cost whilst the paper-based review adjusted 4.9% from a total of GHS57.50 million (USD15.09 m) claims cost received, and the difference was significant (p < 0.001). However, there were no significant differences in claims cost adjustment rate between healthcare facility types by the electronic-based (p = 0.0656) and by the paper-based reviews (p = 0.6484). The electronic-based review adjusted significantly higher claims cost than the paper-based claims review. Scaling up the electronic-based review to cover claims from all accredited care providers could reduce spurious claims cost to the scheme and ensure long term financial sustainability.

  8. Economics of food irradiation: Comparison between electron accelerators and cobalt-60

    NASA Astrophysics Data System (ADS)

    Morrison, R. M.

    The Codex Alimentarius Commission's proposed international standard permits three types of ionizing radiation to be used on foods: gamma rays from radioactive cobalt-60 or cesium-137, high energy electrons, and x-rays. The latter two types of radiation are produced by electron accelerators powered by electricity. Unlike gamma rays and x-rays which can penetrate pallet loads of foods, electrons of the allowed energy levels only penetrate 1 to 3 inches when irradiated from one side. Thus, electrons are limited to treating the surface of foods or foods in thin packages or a shallow stream of grains, powders, or liquids. Average costs per kilogram (kg) of irradiating selected foods are similar for the electron accelerator and cobalt-60 irradiators analyzed in this study, but initial investment costs generally vary by U.S. $1 million. Irradiation treatment costs range from 1 to 15 U.S. cents per kg for the foods and annual volumes examined with larger volumes having lower treatment costs. Cobalt-60 is less expensive than electrons when annual volumes are below 23 million kgs. For radiation source requirements above the equivalent of about 1 million curies of cobalt-60, electrons become more economical. The largest differences in costs occur with the papaya irradiators where using x-rays to penetrate the fruit is more expensive than using cobalt-60.

  9. 47 CFR 32.2211 - Non-digital switching.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... switching. (a) This account shall include: (1) Original cost of stored program control analog circuit-switching and associated equipment. (2) Cost of remote analog electronic circuit switches. (3) Original cost of non-electronic circuit-switching equipment such as Step-by-Step, Crossbar, and Other Electro...

  10. 47 CFR 32.2211 - Non-digital switching.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... switching. (a) This account shall include: (1) Original cost of stored program control analog circuit-switching and associated equipment. (2) Cost of remote analog electronic circuit switches. (3) Original cost of non-electronic circuit-switching equipment such as Step-by-Step, Crossbar, and Other Electro...

  11. 47 CFR 32.2211 - Non-digital switching.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... switching. (a) This account shall include: (1) Original cost of stored program control analog circuit-switching and associated equipment. (2) Cost of remote analog electronic circuit switches. (3) Original cost of non-electronic circuit-switching equipment such as Step-by-Step, Crossbar, and Other Electro...

  12. 47 CFR 32.2211 - Non-digital switching.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... switching. (a) This account shall include: (1) Original cost of stored program control analog circuit-switching and associated equipment. (2) Cost of remote analog electronic circuit switches. (3) Original cost of non-electronic circuit-switching equipment such as Step-by-Step, Crossbar, and Other Electro...

  13. 47 CFR 32.2211 - Non-digital switching.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... switching. (a) This account shall include: (1) Original cost of stored program control analog circuit-switching and associated equipment. (2) Cost of remote analog electronic circuit switches. (3) Original cost of non-electronic circuit-switching equipment such as Step-by-Step, Crossbar, and Other Electro...

  14. The transforming effect of handheld computers on nursing practice.

    PubMed

    Thompson, Brent W

    2005-01-01

    Handheld computers have the power to transform nursing care. The roots of this power are the shift to decentralization of communication, electronic health records, and nurses' greater need for information at the point of care. This article discusses the effects of handheld resources, calculators, databases, electronic health records, and communication devices on nursing practice. The US government has articulated the necessity of implementing the use of handheld computers in healthcare. Nurse administrators need to encourage and promote the diffusion of this technology, which can reduce costs and improve care.

  15. Polyimide-Epoxy Composites with Superior Bendable Properties for Application in Flexible Electronics

    NASA Astrophysics Data System (ADS)

    Lee, Sangyoup; Yoo, Taewon; Han, Youngyu; Kim, Hanglim; Han, Haksoo

    2017-08-01

    The need for flexible electronics with outstanding bending properties is increasing due to the demand for wearable devices and next-generation flexible or rollable smartphones. In addition, the requirements for flexible or rigid-flexible electronics are sharply increasing to achieve the design of space-saving electronic devices. In this regard, coverlay (CL) film is a key material used in the bending area of flexible electronics, albeit infrequently. Because flexible electronics undergo folding and unfolding numerous times, CL films with superior mechanical and bending properties are required so that the bending area can endure such severe stress. However, because current CL films are only used for a designated bending area in the flexible electronics panel, their highly complicated and expensive manufacturing procedure is a disadvantage. In addition, the thickness of CL films must be decreased to satisfy the ongoing requirement for increasingly thin products. However, due to the limitations of the two-layer structure of existing CL films, the manufacturing process cannot be made more cost effective by simply applying more thin film onto the board. To address this problem, we have developed liquid coverlay inks (LCIs) with superior bendable properties, in comparison with CL films, when applied onto flexible electronics using a screen-printing method. The results show that LCIs have the potential to become one of the leading candidates to replace existing CL films because of their lower cost and faster manufacturing process.

  16. Economic evaluations of tobacco control mass media campaigns: a systematic review

    PubMed Central

    Atusingwize, Edwinah; Lewis, Sarah; Langley, Tessa

    2015-01-01

    Background International evidence shows that mass media campaigns are effective tobacco control interventions. However, they require substantial investment; a key question is whether their costs are justified by their benefits. The aim of this study was to systematically and comprehensively review economic evaluations of tobacco control mass media campaigns. Methods An electronic search of databases and grey literature was conducted to identify all published economic evaluations of tobacco control mass media campaigns. The authors reviewed studies independently and assessed the quality of studies using the Drummond 10-point checklist. A narrative synthesis was used to summarise the key features and quality of the identified studies. Results 10 studies met the inclusion criteria and were included in the review. All the studies included a cost effectiveness analysis, a cost utility analysis or both. The methods were highly heterogeneous, particularly in terms of the types of costs included. On the whole, studies were well conducted, but the interventions were often poorly described in terms of campaign content and intensity, and cost information was frequently inadequate. All studies concluded that tobacco control mass media campaigns are a cost effective public health intervention. Conclusions The evidence on the cost effectiveness of tobacco control mass media campaigns is limited, but of acceptable quality and consistently suggests that they offer good value for money. PMID:24985730

  17. Power Electronics Packaging Reliability | Transportation Research | NREL

    Science.gov Websites

    interface materials, are a key enabling technology for compact, lightweight, low-cost, and reliable power , reliability, and cost. High-temperature bonded interface materials are an important facilitating technology for compact, lightweight, low-cost, reliable power electronics packaging that fully utilizes the

  18. 48 CFR 231.205-71 - Cost of remedy for use or inclusion of counterfeit electronic parts and suspect counterfeit...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... inclusion of counterfeit electronic parts and suspect counterfeit electronic parts. 231.205-71 Section 231... Organizations 231.205-71 Cost of remedy for use or inclusion of counterfeit electronic parts and suspect... remedy the use or inclusion of such parts are unallowable, unless— (1) The contractor has an operational...

  19. A method to restrain the charging effect on an insulating substrate in high energy electron beam lithography

    NASA Astrophysics Data System (ADS)

    Mingyan, Yu; Shirui, Zhao; Yupeng, Jing; Yunbo, Shi; Baoqin, Chen

    2014-12-01

    Pattern distortions caused by the charging effect should be reduced while using the electron beam lithography process on an insulating substrate. We have developed a novel process by using the SX AR-PC 5000/90.1 solution as a spin-coated conductive layer, to help to fabricate nanoscale patterns of poly-methyl-methacrylate polymer resist on glass for phased array device application. This method can restrain the influence of the charging effect on the insulating substrate effectively. Experimental results show that the novel process can solve the problems of the distortion of resist patterns and electron beam main field stitching error, thus ensuring the accuracy of the stitching and overlay of the electron beam lithography system. The main characteristic of the novel process is that it is compatible to the multi-layer semiconductor process inside a clean room, and is a green process, quite simple, fast, and low cost. It can also provide a broad scope in the device development on insulating the substrate, such as high density biochips, flexible electronics and liquid crystal display screens.

  20. Enabling cost-effective multimodal trip planners through open transit data : [summary].

    DOT National Transportation Integrated Search

    2011-01-01

    Electronic navigation systems are now common : and widely used -- via Internet services, handheld : devices, and devices in vehicles -- to guide drivers : using instructions and maps. Next generation : systems will plan trips by other modes, includin...

  1. The Information Revolution.

    ERIC Educational Resources Information Center

    Gilder, George

    1993-01-01

    A technological revolution is erupting all about us. A millionfold rise in computation and communications cost effectiveness will transform all industries and bureaucracies. The information revolution is a decentralizing, microcosmic electronic force opposing the centralizing, controlling Industrial-Age mentality persisting in schools. Television…

  2. Economic Evaluation of Family Planning Interventions in Low and Middle Income Countries; A Systematic Review.

    PubMed

    Zakiyah, Neily; van Asselt, Antoinette D I; Roijmans, Frank; Postma, Maarten J

    2016-01-01

    A significant number of women in low and middle income countries (L-MICs) who need any family planning, experience a lack in access to modern effective methods. This study was conducted to review potential cost effectiveness of scaling up family planning interventions in these regions from the published literatures and assess their implication for policy and future research. A systematic review was performed in several electronic databases i.e Medline (Pubmed), Embase, Popline, The National Bureau of Economic Research (NBER), EBSCOHost, and The Cochrane Library. Articles reporting full economic evaluations of strategies to improve family planning interventions in one or more L-MICs, published between 1995 until 2015 were eligible for inclusion. Data was synthesized and analyzed using a narrative approach and the reporting quality of the included studies was assessed using the Consolidated Health Economic Evaluation Reporting Standards (CHEERS) statement. From 920 references screened, 9 studies were eligible for inclusion. Six references assessed cost effectiveness of improving family planning interventions in one or more L-MICs, while the rest assessed costs and consequences of integrating family planning and HIV services, concerning sub-Saharan Africa. Assembled evidence suggested that improving family planning interventions is cost effective in a variety of L-MICs as measured against accepted international cost effectiveness benchmarks. In areas with high HIV prevalence, integrating family planning and HIV services can be efficient and cost effective; however the evidence is only supported by a very limited number of studies. The major drivers of cost effectiveness were cost of increasing coverage, effectiveness of the interventions and country-specific factors. Improving family planning interventions in low and middle income countries appears to be cost-effective. Additional economic evaluation studies with improved reporting quality are necessary to generate further evidence on costs, cost-effectiveness, and affordability, and to support increased funding and investments in family planning programs.

  3. Economic Evaluation of Family Planning Interventions in Low and Middle Income Countries; A Systematic Review

    PubMed Central

    Zakiyah, Neily; van Asselt, Antoinette D. I.; Roijmans, Frank; Postma, Maarten J.

    2016-01-01

    Background A significant number of women in low and middle income countries (L-MICs) who need any family planning, experience a lack in access to modern effective methods. This study was conducted to review potential cost effectiveness of scaling up family planning interventions in these regions from the published literatures and assess their implication for policy and future research. Study design A systematic review was performed in several electronic databases i.e Medline (Pubmed), Embase, Popline, The National Bureau of Economic Research (NBER), EBSCOHost, and The Cochrane Library. Articles reporting full economic evaluations of strategies to improve family planning interventions in one or more L-MICs, published between 1995 until 2015 were eligible for inclusion. Data was synthesized and analyzed using a narrative approach and the reporting quality of the included studies was assessed using the Consolidated Health Economic Evaluation Reporting Standards (CHEERS) statement. Results From 920 references screened, 9 studies were eligible for inclusion. Six references assessed cost effectiveness of improving family planning interventions in one or more L-MICs, while the rest assessed costs and consequences of integrating family planning and HIV services, concerning sub-Saharan Africa. Assembled evidence suggested that improving family planning interventions is cost effective in a variety of L-MICs as measured against accepted international cost effectiveness benchmarks. In areas with high HIV prevalence, integrating family planning and HIV services can be efficient and cost effective; however the evidence is only supported by a very limited number of studies. The major drivers of cost effectiveness were cost of increasing coverage, effectiveness of the interventions and country-specific factors. Conclusion Improving family planning interventions in low and middle income countries appears to be cost-effective. Additional economic evaluation studies with improved reporting quality are necessary to generate further evidence on costs, cost-effectiveness, and affordability, and to support increased funding and investments in family planning programs. PMID:27992552

  4. Economic Evaluation of Implant-Supported Overdentures in Edentulous Patients: A Systematic Review.

    PubMed

    Zhang, Qi; Jin, Xin; Yu, Mengliu; Ou, Guoming; Matsui, Hiroyuki; Liang, Xing; Sasaki, Keiichi

    Edentulous patients benefit significantly from implant-supported overdenture prostheses. The purpose of this systematic review was to evaluate the cost-effectiveness of implant-supported overdentures (IODs) for edentulous patients. The search was limited to studies written in English and included an electronic and manual search through MEDLINE (Ovid, 1946 to November 2015), Embase (Ovid, 1966 to November 2015), Cochrane Central Register of Controlled Trials (CENTRAL) (to November 2015), and PubMed (to November 2015). Two investigators extracted the data and assessed the studies independently. No meta-analysis was conducted due to the high heterogeneity within the literature. Of the initial 583 selected articles, 10 studies involving 802 participants were included. Of these, 6 studies had a high risk of bias and the rest had an unclear risk of bias. Implant-supported prostheses were more cost-effective when compared to conventional dentures and fixed implant-supported prostheses. Overdentures supported by two implants and magnet attachment were reported as cost-effective. Implant-supported overdentures are a cost-effective treatment for edentulous patients. More clinical studies with appropriate scientific vigor are required to further assess the cost-effectiveness of implant-supported overdentures.

  5. From the Field: Peace through Cyberspace.

    ERIC Educational Resources Information Center

    Cantieri, Patricia

    2001-01-01

    Describes the successful Kids for Peace movement, which electronically links students from schools around the world in a week of prayer, study and good works. States that a school can register for the pilgrimage by e-mailing the Web site. Highlights the effectiveness of connecting schools via the Internet-it is cost-effective, free to use, and…

  6. Solution-Processed Donor-Acceptor Polymer Nanowire Network Semiconductors For High-Performance Field-Effect Transistors

    PubMed Central

    Lei, Yanlian; Deng, Ping; Li, Jun; Lin, Ming; Zhu, Furong; Ng, Tsz-Wai; Lee, Chun-Sing; Ong, Beng S.

    2016-01-01

    Organic field-effect transistors (OFETs) represent a low-cost transistor technology for creating next-generation large-area, flexible and ultra-low-cost electronics. Conjugated electron donor-acceptor (D-A) polymers have surfaced as ideal channel semiconductor candidates for OFETs. However, high-molecular weight (MW) D-A polymer semiconductors, which offer high field-effect mobility, generally suffer from processing complications due to limited solubility. Conversely, the readily soluble, low-MW D-A polymers give low mobility. We report herein a facile solution process which transformed a lower-MW, low-mobility diketopyrrolopyrrole-dithienylthieno[3,2-b]thiophene (I) into a high crystalline order and high-mobility semiconductor for OFETs applications. The process involved solution fabrication of a channel semiconductor film from a lower-MW (I) and polystyrene blends. With the help of cooperative shifting motion of polystyrene chain segments, (I) readily self-assembled and crystallized out in the polystyrene matrix as an interpenetrating, nanowire semiconductor network, providing significantly enhanced mobility (over 8 cm2V−1s−1), on/off ratio (107), and other desirable field-effect properties that meet impactful OFET application requirements. PMID:27091315

  7. Innovative Medical Technology, Health Technology Assessment, and Health Policy: The Case of Remote Patient Monitoring of Cardiac Implantable Electronic Devices in South Korea.

    PubMed

    Lee, Sang-Soo; Salole, Eugene

    2017-01-01

    In many developed countries with universal coverage healthcare systems, payers require new medical technologies to be assessed as safe, effective, and cost-effective through health technology assessment (HTA) before approval for reimbursement coverage and market access. However, in some cases, HTA is not the sole criterion for decision-making and other factors override the evidence. Remote patient monitoring (RPM) for cardiac implantable electronic devices, a novel technology recognized as safe, effective, and cost-effective, and the standard of care in many countries, is prohibited in South Korea. This peculiar situation is apparently due to deficiencies in healthcare policy and the delivery system and also to poor engagement between stakeholders. We propose that a higher level of engagement and trust between stakeholders needs to be developed, and healthcare providers should be involved in the early development of health policy, so that unnecessary barriers to access to useful medical technology are corrected, thereby allowing Koreans to enjoy the benefits available in other developed countries.

  8. Design of Pd/PANI/Pd sandwich-structured nanotube array catalysts with special shape effects and synergistic effects for ethanol electrooxidation.

    PubMed

    Wang, An-Liang; Xu, Han; Feng, Jin-Xian; Ding, Liang-Xin; Tong, Ye-Xiang; Li, Gao-Ren

    2013-07-24

    Low cost, high activity, and long-term durability are the main requirements for commercializing fuel cell electrocatalysts. Despite tremendous efforts, developing non-Pt anode electrocatalysts with high activity and long-term durability at low cost remains a significant technical challenge. Here we report a new type of hybrid Pd/PANI/Pd sandwich-structured nanotube array (SNTA) to exploit shape effects and synergistic effects of Pd-PANI composites for the oxidation of small organic molecules for direct alcohol fuel cells. These synthesized Pd/PANI/Pd SNTAs exhibit significantly improved electrocatalytic activity and durability compared with Pd NTAs and commercial Pd/C catalysts. The unique SNTAs provide fast transport and short diffusion paths for electroactive species and high utilization rate of catalysts. Besides the merits of nanotube arrays, the improved electrocatalytic activity and durability are especially attributed to the special Pd/PANI/Pd sandwich-like nanostructures, which results in electron delocalization between Pd d orbitals and PANI π-conjugated ligands and in electron transfer from Pd to PANI.

  9. Multicast routing for wavelength-routed WDM networks with dynamic membership

    NASA Astrophysics Data System (ADS)

    Huang, Nen-Fu; Liu, Te-Lung; Wang, Yao-Tzung; Li, Bo

    2000-09-01

    Future broadband networks must support integrated services and offer flexible bandwidth usage. In our previous work, we explore the optical link control layer on the top of optical layer that enables the possibility of bandwidth on-demand service directly over wavelength division multiplexed (WDM) networks. Today, more and more applications and services such as video-conferencing software and Virtual LAN service require multicast support over the underlying networks. Currently, it is difficult to provide wavelength multicast over the optical switches without optical/electronic conversions although the conversion takes extra cost. In this paper, based on the proposed wavelength router architecture (equipped with ATM switches to offer O/E and E/O conversions when necessary), a dynamic multicast routing algorithm is proposed to furnish multicast services over WDM networks. The goal is to joint a new group member into the multicast tree so that the cost, including the link cost and the optical/electronic conversion cost, is kept as less as possible. The effectiveness of the proposed wavelength router architecture as well as the dynamic multicast algorithm is evaluated by simulation.

  10. Solid-State Photomultiplier with Integrated Front End Electronics

    NASA Astrophysics Data System (ADS)

    Christian, James; Stapels, Christopher; Johnson, Erik; Mukhopadhyay, Sharmistha; Jie Chen, Xiao; Miskimen, Rory

    2009-10-01

    The instrumentation cost of physics experiments has been reduced per channel, by the use of solid-state detectors, but these cost-effective techniques have not been translated to scintillation-based detectors. When considering photodetectors, the cost per channel is determined by the use of high-voltage, analog-to-digital converters, BNC cables, and any other ancillary devices. The overhead associated with device operation limits the number of channels for the detector system, while potentially limiting the scope of physics that can be explored. The PRIMEX experiment at JLab, which is being designed to measure the radiative widths of the η and η' pseudo-scalar mesons for a more comprehensive understanding of QCD at low energies, is an example where CMOS solid-state photomultipliers (SSPMs) can be implemented. The ubiquitous nature of CMOS allows for on-chip signal processing to provide front-end electronics within the detector package. We present the results of the device development for the PRIMEX calorimeter, discussing the characteristics of SSPMs, the potential cost savings, and experimental results of on-chip signal processing.

  11. Effective Strategies to Recruit Young Adults Into the TXT2BFiT mHealth Randomized Controlled Trial for Weight Gain Prevention

    PubMed Central

    Balestracci, Kate; Wong, Annette TY; Hebden, Lana; McGeechan, Kevin; Denney-Wilson, Elizabeth; Harris, Mark F; Phongsavan, Philayrath; Bauman, Adrian; Allman-Farinelli, Margaret

    2015-01-01

    Background Younger adults are difficult to engage in preventive health, yet in Australia they are gaining more weight and increasing in waist circumference faster than middle-to-older adults. A further challenge to engaging 18- to 35-year-olds in interventions is the limited reporting of outcomes of recruitment strategies. Objective This paper describes the outcomes of strategies used to recruit young adults to a randomized controlled trial (RCT), healthy lifestyle mHealth program, TXT2BFiT, for prevention of weight gain. The progression from enquiry through eligibility check to randomization into the trial and the costs of recruitment strategies are reported. Factors associated with nonparticipation are explored. Methods Participants were recruited either via letters of invitation from general practitioners (GPs) or via electronic or print advertisements, including Facebook and Google—social media and advertising—university electronic newsletters, printed posters, mailbox drops, and newspapers. Participants recruited from GP invitation letters had an appointment booked with their GP for eligibility screening. Those recruited from other methods were sent an information pack to seek approval to participate from their own GP. The total number and source of enquiries were categorized according to eligibility and subsequent completion of steps to enrolment. Cost data and details of recruitment strategies were recorded. Results From 1181 enquiries in total from all strategies, 250 (21.17%) participants were randomized. A total of 5311 invitation letters were sent from 12 GP practices—16 participating GPs. A total of 131 patients enquired with 68 participants randomized (68/74 of those eligible, 92%). The other recruitment methods yielded the remaining 182 randomized participants. Enrolment from print media was 26% of enquiries, from electronic media was 20%, and from other methods was 3%. Across all strategies the average cost of recruitment was Australian Dollar (AUD) $139 per person. The least expensive modality was electronic (AUD $37), largely due to a free feature story on one university Web home page, despite Facebook advertising costing AUD $945 per enrolment. The most expensive was print media at AUD $213 and GP letters at AUD $145 per enrolment. Conclusions The research indicated that free electronic media was the most cost-effective strategy, with GP letters the least expensive of the paid strategies in comparison to the other strategies. This study is an important contribution for future research into efficacy, translation, and implementation of cost-effective programs for the prevention of weight gain in young adults. Procedural frameworks for recruitment protocols are required, along with systematic reporting of recruitment strategies to reduce unnecessary expenditure and allow for valuable public health prevention programs to go beyond the research setting. Trial Registration Australian New Zealand Clinical Trials Registry (ANZCTR): ACTRN12612000924853; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=362872 (Archived by WebCite at http://www.webcitation.org/6YpNfv1gI). PMID:26048581

  12. Effective Strategies to Recruit Young Adults Into the TXT2BFiT mHealth Randomized Controlled Trial for Weight Gain Prevention.

    PubMed

    Partridge, Stephanie R; Balestracci, Kate; Wong, Annette Ty; Hebden, Lana; McGeechan, Kevin; Denney-Wilson, Elizabeth; Harris, Mark F; Phongsavan, Philayrath; Bauman, Adrian; Allman-Farinelli, Margaret

    2015-06-05

    Younger adults are difficult to engage in preventive health, yet in Australia they are gaining more weight and increasing in waist circumference faster than middle-to-older adults. A further challenge to engaging 18- to 35-year-olds in interventions is the limited reporting of outcomes of recruitment strategies. This paper describes the outcomes of strategies used to recruit young adults to a randomized controlled trial (RCT), healthy lifestyle mHealth program, TXT2BFiT, for prevention of weight gain. The progression from enquiry through eligibility check to randomization into the trial and the costs of recruitment strategies are reported. Factors associated with nonparticipation are explored. Participants were recruited either via letters of invitation from general practitioners (GPs) or via electronic or print advertisements, including Facebook and Google-social media and advertising-university electronic newsletters, printed posters, mailbox drops, and newspapers. Participants recruited from GP invitation letters had an appointment booked with their GP for eligibility screening. Those recruited from other methods were sent an information pack to seek approval to participate from their own GP. The total number and source of enquiries were categorized according to eligibility and subsequent completion of steps to enrolment. Cost data and details of recruitment strategies were recorded. From 1181 enquiries in total from all strategies, 250 (21.17%) participants were randomized. A total of 5311 invitation letters were sent from 12 GP practices-16 participating GPs. A total of 131 patients enquired with 68 participants randomized (68/74 of those eligible, 92%). The other recruitment methods yielded the remaining 182 randomized participants. Enrolment from print media was 26% of enquiries, from electronic media was 20%, and from other methods was 3%. Across all strategies the average cost of recruitment was Australian Dollar (AUD) $139 per person. The least expensive modality was electronic (AUD $37), largely due to a free feature story on one university Web home page, despite Facebook advertising costing AUD $945 per enrolment. The most expensive was print media at AUD $213 and GP letters at AUD $145 per enrolment. The research indicated that free electronic media was the most cost-effective strategy, with GP letters the least expensive of the paid strategies in comparison to the other strategies. This study is an important contribution for future research into efficacy, translation, and implementation of cost-effective programs for the prevention of weight gain in young adults. Procedural frameworks for recruitment protocols are required, along with systematic reporting of recruitment strategies to reduce unnecessary expenditure and allow for valuable public health prevention programs to go beyond the research setting. Australian New Zealand Clinical Trials Registry (ANZCTR): ACTRN12612000924853; https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=362872 (Archived by WebCite at http://www.webcitation.org/6YpNfv1gI).

  13. Caught in the Net: Notes from the Electronic Underground.

    ERIC Educational Resources Information Center

    Readings, Bill

    Framed by the rising costs of traditional scholarly publishing and the increasing restrictions on library budgets, the turn to electronic publishing seems to be the way of the future, according to the publisher of an electronic journal, "Surfaces." Costs and delays of production and distribution are massively reduced. The electronic…

  14. Consumer Cost Differences for Traditional and Internet Markets.

    ERIC Educational Resources Information Center

    Shaw, Michael J.; Strader, Troy J.

    1999-01-01

    Addresses research issues related to the economics of electronic, Internet-based markets. Discusses consumer cost-based differences for traditional and electronic markets; revenue implications for sellers and transaction intermediaries; and results of an empirical, survey-based study of an electronic market in the sports trading-card industry.…

  15. Compact low-cost detection electronics for optical coherence imaging

    PubMed Central

    Akcay, A. C.; Lee, K. S.; Furenlid, L. R.; Costa, M. A.; Rolland, J. P.

    2015-01-01

    A compact and low-cost detection electronics scheme for optical coherence imaging is demonstrated. The performance of the designed electronics is analyzed in comparison to a commercial lock-in amplifier of equal bandwidth. Images of a fresh-onion sample are presented for each detection configuration. PMID:26617422

  16. North American International Society for Microbial Electrochemical Technologies Meeting (Abstracts)

    DTIC Science & Technology

    2016-04-18

    systems. Unlike the well-studied case of dissolved oxygen (D.O.) effects on the facultative metabolic shift between aerobic respiration and nitrate...The Pt catalyst can effectively catalyze oxygen reduction and ensure a healthy operation of bioelectrochemical systems but its high cost limits the... effect of COEs on other species in bioelectrochemical systems. Effects of additional electron acceptors in bio-anodic processes: oxygen and sulfate

  17. An analysis of preferences for hazardous substances free products: manufacturing, use and end of life of mobile phones.

    PubMed

    Kaushal, Rajendra Kumar; Nema, Arvind K

    2012-11-01

    Electronic communication devices such as mobile phones pose significant environmental risks when disposed of after the end of their useful life. Mobile communication devices are one of the fastest growing contributors to the electronic waste (e-waste) stream. Recent legislative pressure and increasing awareness about the environmental risk associated with the hazardous components of the electronic products warrants the manufacturers to reduce or replace the hazardous materials with alternatives. The present study analyses the economic consequences of reducing or replacing these hazardous materials and the possible response of the consumers. A strategic game theory model has been applied in this paper for manufacturer and consumers considering the cost difference between hazardous substances free (HSF) and hazardous substance (HS) mobile. Results suggest that the HSF mobiles can be a preferred choice of the manufacturers as well as consumers if the cost of disposal of HS mobiles can be internalized and a marginal incentive (e.g. 0.9% for a cost difference to 5%, and 5.3% for a cost difference to 10%) is given. The study further highlights the need for realizing the fact that passing on the incentives to the consumers in order to promote schemes for return back to manufacturer at its end of life for effective reuse and recycling gives higher returns.

  18. Electronic case report forms and electronic data capture within clinical trials and pharmacoepidemiology.

    PubMed

    Rorie, David A; Flynn, Robert W V; Grieve, Kerr; Doney, Alexander; Mackenzie, Isla; MacDonald, Thomas M; Rogers, Amy

    2017-09-01

    Researchers in clinical and pharmacoepidemiology fields have adopted information technology (IT) and electronic data capture, but these remain underused despite the benefits. This review discusses electronic case report forms and electronic data capture, specifically within pharmacoepidemiology and clinical research. The review used PubMed and the Institute of Electrical and Electronic Engineers library. Search terms used were agreed by the authors and documented. PubMed is medical and health based, whereas Institute of Electrical and Electronic Engineers is technology based. The review focuses on electronic case report forms and electronic data capture, but briefly considers other relevant topics; consent, ethics and security. There were 1126 papers found using the search terms. Manual filtering and reviewing of abstracts further condensed this number to 136 relevant manuscripts. The papers were further categorized: 17 contained study data; 40 observational data; 27 anecdotal data; 47 covering methodology or design of systems; one case study; one literature review; two feasibility studies; and one cost analysis. Electronic case report forms, electronic data capture and IT in general are viewed with enthusiasm and are seen as a cost-effective means of improving research efficiency, educating participants and improving trial recruitment, provided concerns about how data will be protected from misuse can be addressed. Clear operational guidelines and best practises are key for healthcare providers, and researchers adopting IT, and further work is needed on improving integration of new technologies with current systems. A robust method of evaluation for technical innovation is required. © 2017 The Authors. British Journal of Clinical Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society.

  19. Radiobiological effectiveness of laser accelerated electrons in comparison to electron beams from a conventional linear accelerator.

    PubMed

    Laschinsky, Lydia; Baumann, Michael; Beyreuther, Elke; Enghardt, Wolfgang; Kaluza, Malte; Karsch, Leonhard; Lessmann, Elisabeth; Naumburger, Doreen; Nicolai, Maria; Richter, Christian; Sauerbrey, Roland; Schlenvoigt, Hans-Peter; Pawelke, Jörg

    2012-01-01

    The notable progress in laser particle acceleration technology promises potential medical application in cancer therapy through compact and cost effective laser devices that are suitable for already existing clinics. Previously, consequences on the radiobiological response by laser driven particle beams characterised by an ultra high peak dose rate have to be investigated. Therefore, tumour and non-malignant cells were irradiated with pulsed laser accelerated electrons at the JETI facility for the comparison with continuous electrons of a conventional therapy LINAC. Dose response curves were measured for the biological endpoints clonogenic survival and residual DNA double strand breaks. The overall results show no significant differences in radiobiological response for in vitro cell experiments between laser accelerated pulsed and clinical used electron beams. These first systematic in vitro cell response studies with precise dosimetry to laser driven electron beams represent a first step toward the long term aim of the application of laser accelerated particles in radiotherapy.

  20. Electron capture dissociation of polypeptides using a 3 Tesla Fourier transform ion cyclotron resonance mass spectrometer.

    PubMed

    Polfer, Nicolas C; Haselmann, Kim F; Zubarev, Roman A; Langridge-Smith, Pat R R

    2002-01-01

    Electron capture dissociation (ECD) of polypeptides has been demonstrated using a commercially available 3 Tesla Fourier transform ion cyclotron resonance (FTICR) instrument. A conventional rhenium filament, designed for high-energy electron impact ionisation, was used to effect ECD of substance P, bee venom melittin and bovine insulin, oxidised B chain. A retarding field analysis of the effective electron kinetic energy distribution entering the ICR cell suggests that one of the most important parameters governing ECD for this particular instrument is the need to employ low trapping plate voltages. This is shown to maximise the abundance of low-energy electrons. The demonstration of ECD at this relatively low magnetic field strength could offer the prospect of more routine ECD analysis for the wider research community, given the reduced cost of such magnets and (at least theoretically) the greater ease of electron/ion cloud overlap at lower field. Copyright 2002 John Wiley & Sons, Ltd.

  1. Chemical sintering of direct-written silver nanowire flexible electrodes under room temperature.

    PubMed

    Hui, Zhuang; Liu, Yangai; Guo, Wei; Li, Lihang; Mu, Nan; Jin, Chao; Zhu, Ying; Peng, Peng

    2017-07-14

    Transparent and flexible electrodes on cost effective plastic substrates for wearable electronics have attract great attention recently. Due to the conductivity and flexibility in network form, metal nanowire is regarded as one of the most promising candidates for flexible electrode fabrication. Prior to application, low temperature joining of nanowire processes are required to reduce the resistance of electrodes and simultaneously maintain the dimensionality and uniformity of those nanowires. In the present work, we presented an innovative, robust and cost effective method to minimize the heat effect to plastic substrate and silver nanowires which allows silver nanowire electrodes been directly written on polycarbonate substrate and sintered by different electrolyte solutions at room temperature or near. It has been rigorously demonstrated that the resistance of silver nanowire electrodes has been reduced by 90% after chemical sintering at room temperature due to the joining of silver nanowires at junction areas. After ∼1000 bending cycles, the measured resistance of silver nanowire electrode was stable during both up-bending and down-bending states. The changes of silver nanowires after sintering were characterized using x-ray photoelectron spectroscopy and transmission electron microscopy and a sintering mechanism was proposed and validated. This direct-written silver nanowire electrode with good performance has broad applications in flexible electronics fabrication and packaging.

  2. A low cost, modular, and physiologically inspired electronic neuron

    NASA Astrophysics Data System (ADS)

    Sitt, J. D.; Campetella, F.; Aliaga, J.

    2010-12-01

    We describe a low cost design of an electronic neuron, which is designed to represent the dynamical properties of the membrane potential of biological neurons by modeling the states of the membrane channels. This electronic neuron can be used to study the nonlinear properties of the membrane voltage dynamics and to develop and analyze small neuronal circuits using electronic neurons as building blocks.

  3. Point-of-care cluster randomized trial in stroke secondary prevention using electronic health records.

    PubMed

    Dregan, Alex; van Staa, Tjeerd P; McDermott, Lisa; McCann, Gerard; Ashworth, Mark; Charlton, Judith; Wolfe, Charles D A; Rudd, Anthony; Yardley, Lucy; Gulliford, Martin C; Trial Steering Committee

    2014-07-01

    The aim of this study was to evaluate whether the remote introduction of electronic decision support tools into family practices improves risk factor control after first stroke. This study also aimed to develop methods to implement cluster randomized trials in stroke using electronic health records. Family practices were recruited from the UK Clinical Practice Research Datalink and allocated to intervention and control trial arms by minimization. Remotely installed, electronic decision support tools promoted intensified secondary prevention for 12 months with last measure of systolic blood pressure as the primary outcome. Outcome data from electronic health records were analyzed using marginal models. There were 106 Clinical Practice Research Datalink family practices allocated (intervention, 53; control, 53), with 11 391 (control, 5516; intervention, 5875) participants with acute stroke ever diagnosed. Participants at trial practices had similar characteristics as 47,887 patients with stroke at nontrial practices. During the intervention period, blood pressure values were recorded in the electronic health records for 90% and cholesterol values for 84% of participants. After intervention, the latest mean systolic blood pressure was 131.7 (SD, 16.8) mm Hg in the control trial arm and 131.4 (16.7) mm Hg in the intervention trial arm, and adjusted mean difference was -0.56 mm Hg (95% confidence interval, -1.38 to 0.26; P=0.183). The financial cost of the trial was approximately US $22 per participant, or US $2400 per family practice allocated. Large pragmatic intervention studies may be implemented at low cost by using electronic health records. The intervention used in this trial was not found to be effective, and further research is needed to develop more effective intervention strategies. http://www.controlled-trials.com. Current Controlled Trials identifier: ISRCTN35701810. © 2014 American Heart Association, Inc.

  4. Laser applications in advanced chip packaging

    NASA Astrophysics Data System (ADS)

    Müller, Dirk; Held, Andrew; Pätzel, Rainer; Clark, Dave; van Nunen, Joris

    2016-03-01

    While applications such as drilling μ-vias and laser direct imaging have been well established in the electronics industry, the mobile device industry's push for miniaturization is generating new demands for packaging technologies that allow for further reduction in feature size while reducing manufacturing cost. CO lasers have recently become available and their shorter wavelength allows for a smaller focus and drilling hole diameters down to 25μm whilst keeping the cost similar to CO2 lasers. Similarly, nanosecond UV lasers have gained significantly in power, become more reliable and lower in cost. On a separate front, the cost of ownership reduction for Excimer lasers has made this class of lasers attractive for structuring redistribution layers of IC substrates with feature sizes down to 2μm. Improvements in reliability and lower up-front cost for picosecond lasers is enabling applications that previously were only cost effective with mechanical means or long-pulsed lasers. We can now span the gamut from 100μm to 2μm for via drilling and can cost effectively structure redistribution layers with lasers instead of UV lamps or singulate packages with picosecond lasers.

  5. Concept for a Differential Lock and Traction Control Model in Automobiles

    NASA Astrophysics Data System (ADS)

    Shukul, A. K.; Hansra, S. K.

    2014-01-01

    The automobile is a complex integration of electronics and mechanical components. One of the major components is the differential which is limited due to its shortcomings. The paper proposes a concept of a cost effective differential lock and traction for passenger cars to sports utility vehicles alike, employing a parallel braking mechanism coming into action based on the relative speeds of the wheels driven by the differential. The paper highlights the employment of minimum number of components unlike the already existing systems. The system was designed numerically for the traction control and differential lock for the world's cheapest car. The paper manages to come up with all the system parameters and component costing making it a cost effective system.

  6. Cost analysis of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery.

    PubMed

    Fanning, James; Fenton, Bradford; Jean, Geraldine Marie; Chae, Clara

    2011-12-01

    Prophylactic intraoperative ureteral stent placement is performed to decrease operative ureteric injury, though few data are available on the effectiveness of this procedure, and no data are available on its cost. To analyze the cost of prophylactic intraoperative cystoscopic ureteral stents in gynecologic surgery. All cases of prophylactic ureteral stent placement performed in gynecologic surgery during a 1-year period were identified and retrospectively reviewed through the electronic medical records database of Summa Health System. Costs were obtained through the Healthcare Cost Accounting System. The principles of cost-effective analysis were used (ie, explicit and detailed descriptions of costs and cost-effectiveness statistics). Importantly, we evaluated cost and not charges or financial model estimates. In addition, we obtained the contribution margins (ie, the hospital's net profit or loss) for prophylactic ureteral stent placement. Other gynecologic procedures were also analyzed. Among 792 major inpatient gynecologic procedures, 18 cases of prophylactic intraoperative ureteral stents were identified. Median costs were as follows: additional cost of prophylactic intraoperative ureteral stenting, $1580; additional cost of surgical resources, $770; cost of ureteral catheters, $427; cost of surgeons, $383. The contribution margins per case for various gynecologic surgical procedures were as follows: oophorectomy, $2804 profit; abdominal hysterectomy, $2649 profit; laparoscopically assisted vaginal hysterectomy (LAVH), $1760 profit. When intraoperative ureteral stenting was added, the contribution margins changed to the following: oophorectomy, $782 profit; abdominal hysterectomy, $627 profit; LAVH, $262 loss. Overall, the contribution margin profit was decreased by about 85%, from $2400 to $380. Prophylactic intraoperative ureteral stenting in gynecologic surgery decreases a hospital's contribution margin. Because of the expense of this procedure, as well as scientific data suggesting a lack of effectiveness, the authors argue that prophylactic intraoperative ureteral stenting should not be used in gynecologic surgery to decrease operative ureteric injury.

  7. An economic evaluation of colorectal cancer screening in primary care practice.

    PubMed

    Meenan, Richard T; Anderson, Melissa L; Chubak, Jessica; Vernon, Sally W; Fuller, Sharon; Wang, Ching-Yun; Green, Beverly B

    2015-06-01

    Recent colorectal cancer screening studies focus on optimizing adherence. This study evaluated the cost effectiveness of interventions using electronic health records (EHRs); automated mailings; and stepped support increases to improve 2-year colorectal cancer screening adherence. Analyses were based on a parallel-design, randomized trial in which three stepped interventions (EHR-linked mailings ["automated"]; automated plus telephone assistance ["assisted"]; or automated and assisted plus nurse navigation to testing completion or refusal [navigated"]) were compared to usual care. Data were from August 2008 to November 2011, with analyses performed during 2012-2013. Implementation resources were micro-costed; research and registry development costs were excluded. Incremental cost-effectiveness ratios (ICERs) were based on number of participants current for screening per guidelines over 2 years. Bootstrapping examined robustness of results. Intervention delivery cost per participant current for screening ranged from $21 (automated) to $27 (navigated). Inclusion of induced testing costs (e.g., screening colonoscopy) lowered expenditures for automated (ICER=-$159) and assisted (ICER=-$36) relative to usual care over 2 years. Savings arose from increased fecal occult blood testing, substituting for more expensive colonoscopies in usual care. Results were broadly consistent across demographic subgroups. More intensive interventions were consistently likely to be cost effective relative to less intensive interventions, with willingness to pay values of $600-$1,200 for an additional person current for screening yielding ≥80% probability of cost effectiveness. Two-year cost effectiveness of a stepped approach to colorectal cancer screening promotion based on EHR data is indicated, but longer-term cost effectiveness requires further study. Copyright © 2015 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  8. The economics of health information technology in medication management: a systematic review of economic evaluations.

    PubMed

    O'Reilly, Daria; Tarride, Jean-Eric; Goeree, Ron; Lokker, Cynthia; McKibbon, K Ann

    2012-01-01

    To conduct a systematic review and synthesis of the evidence surrounding the cost-effectiveness of health information technology (HIT) in the medication process. Peer-reviewed electronic databases and gray literature were searched to identify studies on HIT used to assist in the medication management process. Articles including an economic component were reviewed for further screening. For this review, full cost-effectiveness analyses, cost-utility analyses and cost-benefit analyses, as well as cost analyses, were eligible for inclusion and synthesis. The 31 studies included were heterogeneous with respect to the HIT evaluated, setting, and economic methods used. Thus the data could not be synthesized, and a narrative review was conducted. Most studies evaluated computer decision support systems in hospital settings in the USA, and only five of the studied performed full economic evaluations. Most studies merely provided cost data; however, useful economic data involves far more input. A full economic evaluation includes a full enumeration of the costs, synthesized with the outcomes of the intervention. The quality of the economic literature in this area is poor. A few studies found that HIT may offer cost advantages despite their increased acquisition costs. However, given the uncertainty that surrounds the costs and outcomes data, and limited study designs, it is difficult to reach any definitive conclusion as to whether the additional costs and benefits represent value for money. Sophisticated concurrent prospective economic evaluations need to be conducted to address whether HIT interventions in the medication management process are cost-effective.

  9. Benefits of Grants.gov to EPA and the Public

    EPA Pesticide Factsheets

    Grants.gov is the single source to find and apply for Federal government-wide competitive grant opportunities.Grants.gov is making it faster, easier and more cost effective for grant applicants to electronically interact with Federal grant making agencies.

  10. Screening for Chlamydia trachomatis: a systematic review of the economic evaluations and modelling

    PubMed Central

    Roberts, T E; Robinson, S; Barton, P; Bryan, S; Low, N

    2006-01-01

    Objective To review systematically and critically, evidence used to derive estimates of costs and cost effectiveness of chlamydia screening. Methods Systematic review. A search of 11 electronic bibliographic databases from the earliest date available to August 2004 using keywords including chlamydia, pelvic inflammatory disease, economic evaluation, and cost. We included studies of chlamydia screening in males and/or females over 14 years, including studies of diagnostic tests, contact tracing, and treatment as part of a screening programme. Outcomes included cases of chlamydia identified and major outcomes averted. We assessed methodological quality and the modelling approach used. Results Of 713 identified papers we included 57 formal economic evaluations and two cost studies. Most studies found chlamydia screening to be cost effective, partner notification to be an effective adjunct, and testing with nucleic acid amplification tests, and treatment with azithromycin to be cost effective. Methodological problems limited the validity of these findings: most studies used static models that are inappropriate for infectious diseases; restricted outcomes were used as a basis for policy recommendations; and high estimates of the probability of chlamydia associated complications might have overestimated cost effectiveness. Two high quality dynamic modelling studies found opportunistic screening to be cost effective but poor reporting or uncertainty about complication rates make interpretation difficult. Conclusion The inappropriate use of static models to study interventions to prevent a communicable disease means that uncertainty remains about whether chlamydia screening programmes are cost effective or not. The results of this review can be used by health service managers in the allocation of resources, and health economists and other researchers who are considering further research in this area. PMID:16731666

  11. A systematic review and cost-effectiveness analysis of tonometer disinfection methods.

    PubMed

    Omar Akhtar, Ahmad; Singh, Hargurinder; Si, Francie; Hodge, William G

    2014-08-01

    The Goldmann applanation tonometer presents the problem of being one of the most widely used pieces of equipment in the ophthalmic clinic and a known risk factor for the transmission of epidemic keratoconjunctivitis (EKC). The purpose of this review is to assess the effectiveness of 3 methods of disinfection: alcohol swabs, immersion in peroxide, and the use of disposable prisms. An economic evaluation is undertaken to assess the cost-effectiveness of the 3 alternatives. In doing so, we contribute an evidence-based overview of the issue at an opportune time, because several jurisdictions are developing protocols regarding tonometer tip disinfection. Systematic review and cost-effectiveness analysis. A comprehensive literature review was undertaken with a librarian, comprising searches of 6 electronic databases and hand searches of the grey literature. A 3-level screening process was undertaken by 2 reviewers according to prespecified inclusion and exclusion criteria. Values from included papers were used to inform a cost-effectiveness analysis undertaken using a decision tree model implemented in TreeAge. The analysis was undertaken from the hospital perspective and included all equipment and labour costs. Synthesis of in vitro data indicates that all 3 methods are plausible methods of disinfection with a 64% reduction in log growth of EKC when peroxide is used compared with alcohol swabs. The incremental cost-effective ratios from the cost-effectiveness analysis were $12,000/case averted using peroxide and $61,000/case averted with Tonosafe as compared with alcohol. Assuming clinical infection rates match in vitro disinfection data, the cost of bleach is high and the cost of Tonosafe is unacceptably high to reduce 1 potential case of adenoviral keratoconjunctivitis. Copyright © 2014. Published by Elsevier Inc.

  12. Cost-effectiveness of a nurse facilitated, cognitive behavioural self-management programme compared with usual care using a CBT manual alone for patients with heart failure: secondary analysis of data from the SEMAPHFOR trial.

    PubMed

    Mejía, Aurelio; Richardson, Gerry; Pattenden, Jill; Cockayne, Sarah; Lewin, Robert

    2014-09-01

    To assess the cost-effectiveness of a nurse facilitated, cognitive behavioural self-management programme for patients with heart failure compared with usual care including the un-facilitated access to the same manual, from the perspective of the NHS. Data were obtained from a pragmatic, multi-centre, randomized controlled 'open' trial conducted in seven centres in the UK between 2006 and 2008. Effectiveness was estimated as Quality-Adjusted Life Years. Resource use was measured prospectively on all patients using information provided by patients in postal questionnaires, case-note review, electronic record review and interviews with patients. Unit costs were obtained from the literature and applied to the relevant resource use to estimate total costs. Multiple imputation was used to handle missing data. There were no substantial differences in the utility scores between treatment groups in all follow-up assessments, in the use of medication or outpatient visits and both groups report a similar frequency of contact with health care professionals. After controlling for baseline utility and using imputed dataset, treatment was associated with a reduction in QALY of 0.004 and a additional cost of £69.49. The probability that the intervention is cost-effective for thresholds between £20,000 and £30,000 is around 45%. There is little evidence that the addition of the intervention had any effect on costs or outcomes. The uncertainty around both estimates of cost and effectiveness mean that it is not reasonable to make recommendations based on cost-effectiveness alone. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Ab initio molecular dynamics with nuclear quantum effects at classical cost: Ring polymer contraction for density functional theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marsalek, Ondrej; Markland, Thomas E., E-mail: tmarkland@stanford.edu

    Path integral molecular dynamics simulations, combined with an ab initio evaluation of interactions using electronic structure theory, incorporate the quantum mechanical nature of both the electrons and nuclei, which are essential to accurately describe systems containing light nuclei. However, path integral simulations have traditionally required a computational cost around two orders of magnitude greater than treating the nuclei classically, making them prohibitively costly for most applications. Here we show that the cost of path integral simulations can be dramatically reduced by extending our ring polymer contraction approach to ab initio molecular dynamics simulations. By using density functional tight binding asmore » a reference system, we show that our ring polymer contraction scheme gives rapid and systematic convergence to the full path integral density functional theory result. We demonstrate the efficiency of this approach in ab initio simulations of liquid water and the reactive protonated and deprotonated water dimer systems. We find that the vast majority of the nuclear quantum effects are accurately captured using contraction to just the ring polymer centroid, which requires the same number of density functional theory calculations as a classical simulation. Combined with a multiple time step scheme using the same reference system, which allows the time step to be increased, this approach is as fast as a typical classical ab initio molecular dynamics simulation and 35× faster than a full path integral calculation, while still exactly including the quantum sampling of nuclei. This development thus offers a route to routinely include nuclear quantum effects in ab initio molecular dynamics simulations at negligible computational cost.« less

  14. Workplace involvement improves return to work rates among employees with back pain on long-term sick leave: a systematic review of the effectiveness and cost-effectiveness of interventions.

    PubMed

    Carroll, Christopher; Rick, Jo; Pilgrim, Hazel; Cameron, Jackie; Hillage, Jim

    2010-01-01

    Long-term sickness absence among workers is a major problem in industrialised countries. The aim of the review is to determine whether interventions involving the workplace are more effective and cost-effective at helping employees on sick leave return to work than those that do not involve the workplace at all. A systematic review of controlled intervention studies and economic evaluations. Sixteen electronic databases and grey literature sources were searched, and reference and citation tracking was performed on included publications. A narrative synthesis was performed. Ten articles were found reporting nine trials from Europe and Canada, and four articles were found evaluating the cost-effectiveness of interventions. The population in eight trials suffered from back pain and related musculoskeletal conditions. Interventions involving employees, health practitioners and employers working together, to implement work modifications for the absentee, were more consistently effective than other interventions. Early intervention was also found to be effective. The majority of trials were of good or moderate quality. Economic evaluations indicated that interventions with a workplace component are likely to be more cost effective than those without. Stakeholder participation and work modification are more effective and cost effective at returning to work adults with musculoskeletal conditions than other workplace-linked interventions, including exercise.

  15. A systematic review of the effectiveness and cost-effectiveness of peer education and peer support in prisons.

    PubMed

    Bagnall, Anne-Marie; South, Jane; Hulme, Claire; Woodall, James; Vinall-Collier, Karen; Raine, Gary; Kinsella, Karina; Dixey, Rachael; Harris, Linda; Wright, Nat M J

    2015-03-25

    Prisoners experience significantly worse health than the general population. This review examines the effectiveness and cost-effectiveness of peer interventions in prison settings. A mixed methods systematic review of effectiveness and cost-effectiveness studies, including qualitative and quantitative synthesis was conducted. In addition to grey literature identified and searches of websites, nineteen electronic databases were searched from 1985 to 2012. Study selection criteria were: Prisoners resident in adult prisons and children resident in Young Offender Institutions (YOIs). Peer-based interventions. Review questions 3 and 4 compared peer and professionally led approaches. Prisoner health or determinants of health; organisational/process outcomes; views of prison populations. Quantitative, qualitative and mixed method evaluations. Fifty-seven studies were included in the effectiveness review and one study in the cost-effectiveness review; most were of poor methodological quality. Evidence suggested that peer education interventions are effective at reducing risky behaviours, and that peer support services are acceptable within the prison environment and have a positive effect on recipients, practically or emotionally. Consistent evidence from many, predominantly qualitative, studies, suggested that being a peer deliverer was associated with positive effects. There was little evidence on cost-effectiveness of peer-based interventions. There is consistent evidence from a large number of studies that being a peer worker is associated with positive health; peer support services are also an acceptable source of help within the prison environment and can have a positive effect on recipients. Research into cost-effectiveness is sparse. PROSPERO ref: CRD42012002349.

  16. Prospects for applications of electron beams in processing of gas and oil hydrocarbons

    NASA Astrophysics Data System (ADS)

    Ponomarev, A. V.; Pershukov, V. A.; Smirnov, V. P.

    2015-12-01

    Waste-free processing of oil and oil gases can be based on electron-beam technologies. Their major advantage is an opportunity of controlled manufacturing of a wide range of products with a higher utility value at moderate temperatures and pressures. The work considers certain key aspects of electron beam technologies applied for the chain cracking of heavy crude oil, for the synthesis of premium gasoline from oil gases, and also for the hydrogenation, alkylation, and isomerization of unsaturated oil products. Electronbeam processing of oil can be embodied via compact mobile modules which are applicable for direct usage at distant oil and gas fields. More cost-effective and reliable electron accelerators should be developed to realize the potential of electron-beam technologies.

  17. Cost-effectiveness of cardiotocography plus ST analysis of the fetal electrocardiogram compared with cardiotocography only.

    PubMed

    Vijgen, Sylvia M C; Westerhuis, Michelle E M H; Opmeer, Brent C; Visser, Gerard H A; Moons, Karl G M; Porath, Martina M; Oei, Guid S; Van Geijn, Herman P; Bolte, Antoinette C; Willekes, Christine; Nijhuis, Jan G; Van Beek, Erik; Graziosi, Giuseppe C M; Schuitemaker, Nico W E; Van Lith, Jan M M; Van Den Akker, Eline S A; Drogtrop, Addy P; Van Dessel, Hendrikus J H M; Rijnders, Robbert J P; Oosterbaan, Herman P; Mol, Ben Willem J; Kwee, Anneke

    2011-07-01

    To assess the cost-effectiveness of addition of ST analysis of the fetal electrocardiogram (ECG; STAN) to cardiotocography (CTG) for fetal surveillance during labor compared with CTG only. Cost-effectiveness analysis based on a randomized clinical trial on ST analysis of the fetal ECG. Obstetric departments of three academic and six general hospitals in The Netherlands. Population. Laboring women with a singleton high-risk pregnancy, a fetus in cephalic presentation, a gestational age >36 weeks and an indication for internal electronic fetal monitoring. A trial-based cost-effectiveness analysis was performed from a health-care provider perspective. Primary health outcome was the incidence of metabolic acidosis measured in the umbilical artery. Direct medical costs were estimated from start of labor to childbirth. Cost-effectiveness was expressed as costs to prevent one case of metabolic acidosis. The incidence of metabolic acidosis was 0.7% in the ST-analysis group and 1.0% in the CTG-only group (relative risk 0.70; 95% confidence interval 0.38-1.28). Per delivery, the mean costs per patient of CTG plus ST analysis (n= 2 827) were €1,345 vs. €1,316 for CTG only (n= 2 840), with a mean difference of €29 (95% confidence interval -€9 to €77) until childbirth. The incremental costs of ST analysis to prevent one case of metabolic acidosis were €9 667. The additional costs of monitoring by ST analysis of the fetal ECG are very limited when compared with monitoring by CTG only and very low compared with the total costs of delivery. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.

  18. Management of radioactive waste gases from PET radiopharmaceutical synthesis using cost effective capture systems integrated with a cyclotron safety system.

    PubMed

    Stimson, D H R; Pringle, A J; Maillet, D; King, A R; Nevin, S T; Venkatachalam, T K; Reutens, D C; Bhalla, R

    2016-09-01

    The emphasis on the reduction of gaseous radioactive effluent associated with PET radiochemistry laboratories has increased. Various radioactive gas capture strategies have been employed historically including expensive automated compression systems. We have implemented a new cost-effective strategy employing gas capture bags with electronic feedback that are integrated with the cyclotron safety system. Our strategy is suitable for multiple automated 18 F radiosynthesis modules and individual automated 11 C radiosynthesis modules. We describe novel gas capture systems that minimize the risk of human error and are routinely used in our facility.

  19. Visual Simulation The Old Way

    NASA Astrophysics Data System (ADS)

    Gomes, Gary G.

    1986-05-01

    A cost effective and supportable color visual system has been developed to provide the necessary visual cues to United States Air Force B-52 bomber pilots training to become proficient at the task of inflight refueling. This camera model visual system approach is not suitable for all simulation applications, but provides a cost effective alternative to digital image generation systems when high fidelity of a single movable object is required. The system consists of a three axis gimballed KC-l35 tanker model, a range carriage mounted color augmented monochrome television camera, interface electronics, a color light valve projector and an infinity optics display system.

  20. PubMed Central

    Turchetti, G.; Bellelli, S.; Palla, I.; Forli, F.

    2011-01-01

    SUMMARY The aim of the study consists in a systematic review concerning the economic evaluation of cochlear implant (CI) in children by searching the main international clinical and economic electronic databases. All primary studies published in English from January 2000 to May 2010 were included. The types of studies selected concerned partial economic evaluation, including direct and indirect costs of cochlear implantation; complete economic evaluation, including minimization of costs, cost-effectiveness analysis (CEA), cost-utility analysis (CUA) and cost-benefit analysis (CBA) performed through observational and experimental studies. A total of 68 articles were obtained from the database research. Of these, 54 did not meet the inclusion criteria and were eliminated. After reading the abstracts of the 14 articles selected, 11 were considered eligible. The articles were then read in full text. Furthermore, 5 articles identified by bibliography research were added manually. After reading 16 of the selected articles, 9 were included in the review. With regard to the studies included, countries examined, objectives, study design, methodology, prospect of analysis adopted, temporal horizon, the cost categories analyzed strongly differ from one study to another. Cost analysis, cost-effectiveness analysis and an analysis of educational costs associated with cochlear implants were performed. Regarding the cost analysis, only two articles reported both direct cost and indirect costs. The direct cost ranged between € 39,507 and € 68,235 (2011 values). The studies related to cost-effectiveness analysis were not easily comparable: one study reported a cost per QALY ranging between $ 5197 and $ 9209; another referred a cost of $ 2154 for QALY if benefits were not discounted, and $ 16,546 if discounted. Educational costs are significant, and increase with the level of hearing loss and type of school attended. This systematic review shows that the healthcare costs are high, but savings in terms of indirect and quality of life costs are also significant. Cochlear implantation in a paediatric age is cost-effective. The exiguity and heterogeneity of studies did not allow detailed comparative analysis of the studies included in the review. PMID:22287822

  1. An efficient and cost-effective method for preparing transmission electron microscopy samples from powders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wen, Haiming; Lin, Yaojun; Seidman, David N.

    The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less

  2. A wearable pressure sensor based on ultra-violet/ozone microstructured carbon nanotube/polydimethylsiloxane arrays for electronic skins.

    PubMed

    Yu, Guohui; Hu, Jingdong; Tan, Jianping; Gao, Yang; Lu, Yongfeng; Xuan, Fuzhen

    2018-03-16

    Pressure sensors with high performance (e.g., a broad pressure sensing range, high sensitivities, rapid response/relaxation speeds, temperature-stable sensing), as well as a cost-effective and highly efficient fabrication method are highly desired for electronic skins. In this research, a high-performance pressure sensor based on microstructured carbon nanotube/polydimethylsiloxane arrays was fabricated using an ultra-violet/ozone (UV/O 3 ) microengineering technique. The UV/O 3 microengineering technique is controllable, cost-effective, and highly efficient since it is conducted at room temperature in an ambient environment. The pressure sensor offers a broad pressure sensing range (7 Pa-50 kPa), a sensitivity of ∼ -0.101 ± 0.005 kPa -1 (<1 kPa), a fast response/relaxation speed of ∼10 ms, a small dependence on temperature variation, and a good cycling stability (>5000 cycles), which is attributed to the UV/O 3 engineered microstructures that amplify and transfer external applied forces and rapidly store/release the energy during the PDMS deformation. The sensors developed show the capability to detect external forces and monitor human health conditions, promising for the potential applications in electronic skin.

  3. A wearable pressure sensor based on ultra-violet/ozone microstructured carbon nanotube/polydimethylsiloxane arrays for electronic skins

    NASA Astrophysics Data System (ADS)

    Yu, Guohui; Hu, Jingdong; Tan, Jianping; Gao, Yang; Lu, Yongfeng; Xuan, Fuzhen

    2018-03-01

    Pressure sensors with high performance (e.g., a broad pressure sensing range, high sensitivities, rapid response/relaxation speeds, temperature-stable sensing), as well as a cost-effective and highly efficient fabrication method are highly desired for electronic skins. In this research, a high-performance pressure sensor based on microstructured carbon nanotube/polydimethylsiloxane arrays was fabricated using an ultra-violet/ozone (UV/O3) microengineering technique. The UV/O3 microengineering technique is controllable, cost-effective, and highly efficient since it is conducted at room temperature in an ambient environment. The pressure sensor offers a broad pressure sensing range (7 Pa-50 kPa), a sensitivity of ˜ -0.101 ± 0.005 kPa-1 (<1 kPa), a fast response/relaxation speed of ˜10 ms, a small dependence on temperature variation, and a good cycling stability (>5000 cycles), which is attributed to the UV/O3 engineered microstructures that amplify and transfer external applied forces and rapidly store/release the energy during the PDMS deformation. The sensors developed show the capability to detect external forces and monitor human health conditions, promising for the potential applications in electronic skin.

  4. An efficient and cost-effective method for preparing transmission electron microscopy samples from powders

    DOE PAGES

    Wen, Haiming; Lin, Yaojun; Seidman, David N.; ...

    2015-09-09

    The preparation of transmission electron microcopy (TEM) samples from powders with particle sizes larger than ~100 nm poses a challenge. The existing methods are complicated and expensive, or have a low probability of success. Herein, we report a modified methodology for preparation of TEM samples from powders, which is efficient, cost-effective, and easy to perform. This method involves mixing powders with an epoxy on a piece of weighing paper, curing the powder–epoxy mixture to form a bulk material, grinding the bulk to obtain a thin foil, punching TEM discs from the foil, dimpling the discs, and ion milling the dimpledmore » discs to electron transparency. Compared with the well established and robust grinding–dimpling–ion-milling method for TEM sample preparation for bulk materials, our modified approach for preparing TEM samples from powders only requires two additional simple steps. In this article, step-by-step procedures for our methodology are described in detail, and important strategies to ensure success are elucidated. Furthermore, our methodology has been applied successfully for preparing TEM samples with large thin areas and high quality for many different mechanically milled metallic powders.« less

  5. The Impact of Electronic Health Records on Ambulatory Costs Among Medicaid Beneficiaries

    PubMed Central

    Adler-Milstein, Julia; Salzberg, Claudia; Franz, Calvin; Orav, E. John; Bates, David Westfall

    2013-01-01

    Background Broad adoption of electronic health records (EHRs) is a potential strategy for curbing healthcare cost growth, which is particularly vital for Medicaid. Despite limited evidence for EHR-related cost savings, the 2009 HITECH Act included incentives for providers to become meaningful users of EHRs. We evaluated a large Massachusetts EHR pilot to obtain early insight into the potential for the national strategy to reduce short-run healthcare costs in the Medicaid population. Methods We calculated monthly ambulatory cost and visit measures from Medicaid claims data for beneficiaries receiving the majority of their care in the three Massachusetts eHealth Collaborative (MAeHC) pilot communities or in six matched control communities. Using a difference-in-differences of slope analysis, we assessed whether cost and visit trajectories differed in the pre-implementation period compared to the post-implementation period for intervention and control community members. Results We found evidence that EHR adoption impacted ambulatory medical cost in two of the three communities, but the effects were in opposite directions. Ambulatory medical costs increased more slowly in one intervention compared to its control communities in the pre-to-post period (difference-in-differences=-1.98%, p<0.001; PMPM savings of $41.60). In contrast, for a second pilot community, ambulatory medical cost increased more slowly in the control communities (difference-in-differences=2.56%, p=0.005; PMPM increase of $43.34). Conclusions As a stand-alone approach, adoption of commercially-available EHRs in community practices did not consistently impact Medicaid costs in the short-run. This suggests that future meaningful use criteria may need to specifically target cost savings and coordinate with payment reform efforts. PMID:24753965

  6. Cost-effectiveness thresholds: methods for setting and examples from around the world.

    PubMed

    Santos, André Soares; Guerra-Junior, Augusto Afonso; Godman, Brian; Morton, Alec; Ruas, Cristina Mariano

    2018-06-01

    Cost-effectiveness thresholds (CETs) are used to judge if an intervention represents sufficient value for money to merit adoption in healthcare systems. The study was motivated by the Brazilian context of HTA, where meetings are being conducted to decide on the definition of a threshold. Areas covered: An electronic search was conducted on Medline (via PubMed), Lilacs (via BVS) and ScienceDirect followed by a complementary search of references of included studies, Google Scholar and conference abstracts. Cost-effectiveness thresholds are usually calculated through three different approaches: the willingness-to-pay, representative of welfare economics; the precedent method, based on the value of an already funded technology; and the opportunity cost method, which links the threshold to the volume of health displaced. An explicit threshold has never been formally adopted in most places. Some countries have defined thresholds, with some flexibility to consider other factors. An implicit threshold could be determined by research of funded cases. Expert commentary: CETs have had an important role as a 'bridging concept' between the world of academic research and the 'real world' of healthcare prioritization. The definition of a cost-effectiveness threshold is paramount for the construction of a transparent and efficient Health Technology Assessment system.

  7. Regioregular narrow-bandgap-conjugated polymers for plastic electronics

    NASA Astrophysics Data System (ADS)

    Ying, Lei; Huang, Fei; Bazan, Guillermo C.

    2017-03-01

    Progress in the molecular design and processing protocols of semiconducting polymers has opened significant opportunities for the fabrication of low-cost plastic electronic devices. Recent studies indicate that field-effect transistors and organic solar cells fabricated using narrow-bandgap regioregular polymers with translational symmetries in the direction of the backbone vector often outperform those containing analogous regiorandom polymers. This review addresses the cutting edge of regioregularity chemistry, in particular how to control the spatial distribution in the molecular structures and how this order translates to more ordered bulk morphologies. The effect of regioregularity on charge transport and photovoltaic properties is also outlined.

  8. A systematic review of cost-effectiveness studies of prevention and treatment for eating disorders.

    PubMed

    Le, Long Khanh-Dao; Hay, Phillipa; Mihalopoulos, Cathrine

    2018-04-01

    Eating disorders are serious mental disorders and are associated with substantial economic and social burden. The aim of this study is to undertake a systematic review of the cost-effectiveness studies of both preventive and treatment interventions for eating disorder. Electronic databases (including the Cochrane Controlled Trial Register, MEDLINE, PsycINFO, Academic Search Complete, Global Health, CINAHL complete, Health Business Elite, Econlit, Health Policy Reference Center and ERIC) were searched for published cost-effectiveness studies of eating disorder prevention and treatment including papers published up to January 2017. The quality of studies was assessed using the Consolidated Health Economic Evaluation Reporting Standards (CHEERS) checklist. In all, 13 studies met the review inclusion criteria as full cost-effectiveness studies and 8 were published since 2011. The studies included three modelled and one trial-based study focused on prevention, two trial-based and one modelled study for anorexia nervosa treatment and three trial-based studies for bulimia nervosa treatment. The remaining studies targeted binge-eating disorder or non-specific eating disorder treatment. The average percent of CHEERS checklist items reported was 71% (standard deviation 21%). Eating disorder interventions were mainly cost-saving or more effective and more costly compared to comparators; however, some results did not reach statistical significance. In the two studies that achieved 100% CHEERS checklist, one study reported that a cognitive dissonance intervention might be cost-effective for prevention of anorexia nervosa and bulimia nervosa with a 90% participation rate and the second study supported lisdexamfetamine to be cost-effective in the treatment of binge-eating disorder. Insufficient evidence for long-term cost-effectiveness (e.g. over 2 years) was found. Cost-effectiveness studies in eating disorder appear to be increasing in number over the last 6 years. Findings were inconsistent and no firm conclusion can be drawn with regard to comparative value-for-money conclusions. However, some promising interventions were identified. Further research with improved methodology is required.

  9. Health Literacy Assessment of the STOFHLA: Paper versus Electronic Administration Continuation Study

    ERIC Educational Resources Information Center

    Chesser, Amy K.; Keene Woods, Nikki; Wipperman, Jennifer; Wilson, Rachel; Dong, Frank

    2014-01-01

    Low health literacy is associated with poor health outcomes. Research is needed to understand the mechanisms and pathways of its effects. Computer-based assessment tools may improve efficiency and cost-effectiveness of health literacy research. The objective of this preliminary study was to assess if administration of the Short Test of Functional…

  10. On Convergence of Development Costs and Cost Models for Complex Spaceflight Instrument Electronics

    NASA Technical Reports Server (NTRS)

    Kizhner, Semion; Patel, Umeshkumar D.; Kasa, Robert L.; Hestnes, Phyllis; Brown, Tammy; Vootukuru, Madhavi

    2008-01-01

    Development costs of a few recent spaceflight instrument electrical and electronics subsystems have diverged from respective heritage cost model predictions. The cost models used are Grass Roots, Price-H and Parametric Model. These cost models originated in the military and industry around 1970 and were successfully adopted and patched by NASA on a mission-by-mission basis for years. However, the complexity of new instruments recently changed rapidly by orders of magnitude. This is most obvious in the complexity of representative spaceflight instrument electronics' data system. It is now required to perform intermediate processing of digitized data apart from conventional processing of science phenomenon signals from multiple detectors. This involves on-board instrument formatting of computational operands from row data for example, images), multi-million operations per second on large volumes of data in reconfigurable hardware (in addition to processing on a general purpose imbedded or standalone instrument flight computer), as well as making decisions for on-board system adaptation and resource reconfiguration. The instrument data system is now tasked to perform more functions, such as forming packets and instrument-level data compression of more than one data stream, which are traditionally performed by the spacecraft command and data handling system. It is furthermore required that the electronics box for new complex instruments is developed for one-digit watt power consumption, small size and that it is light-weight, and delivers super-computing capabilities. The conflict between the actual development cost of newer complex instruments and its electronics components' heritage cost model predictions seems to be irreconcilable. This conflict and an approach to its resolution are addressed in this paper by determining the complexity parameters, complexity index, and their use in enhanced cost model.

  11. Assessing the cost of electronic health records: a review of cost indicators.

    PubMed

    Gallego, Ana Isabel; Gagnon, Marie-Pierre; Desmartis, Marie

    2010-11-01

    We systematically reviewed PubMed and EBSCO business, looking for cost indicators of electronic health record (EHR) implementations and their associated benefit indicators. We provide a set of the most common cost and benefit (CB) indicators used in the EHR literature, as well as an overall estimate of the CB related to EHR implementation. Overall, CB evaluation of EHR implementation showed a rapid capital-recovering process. On average, the annual benefits were 76.5% of the first-year costs and 308.6% of the annual costs. However, the initial investments were not recovered in a few studied implementations. Distinctions in reporting fixed and variable costs are suggested.

  12. Adaptive array antenna for satellite cellular and direct broadcast communications

    NASA Technical Reports Server (NTRS)

    Horton, Charles R.; Abend, Kenneth

    1993-01-01

    Adaptive phased-array antennas provide cost-effective implementation of large, light weight apertures with high directivity and precise beamshape control. Adaptive self-calibration allows for relaxation of all mechanical tolerances across the aperture and electrical component tolerances, providing high performance with a low-cost, lightweight array, even in the presence of large physical distortions. Beam-shape is programmable and adaptable to changes in technical and operational requirements. Adaptive digital beam-forming eliminates uplink contention by allowing a single electronically steerable antenna to service a large number of receivers with beams which adaptively focus on one source while eliminating interference from others. A large, adaptively calibrated and fully programmable aperture can also provide precise beam shape control for power-efficient direct broadcast from space. Advanced adaptive digital beamforming technologies are described for: (1) electronic compensation of aperture distortion, (2) multiple receiver adaptive space-time processing, and (3) downlink beam-shape control. Cost considerations for space-based array applications are also discussed.

  13. Large area, low cost space solar cells with optional wraparound contacts

    NASA Technical Reports Server (NTRS)

    Michaels, D.; Mendoza, N.; Williams, R.

    1981-01-01

    Design parameters for two large area, low cost solar cells are presented, and electron irradiation testing, thermal alpha testing, and cell processing are discussed. The devices are a 2 ohm-cm base resistivity silicon cell with an evaporated aluminum reflector produced in a dielectric wraparound cell, and a 10 ohm-cm silicon cell with the BSF/BSR combination and a conventional contact system. Both cells are 5.9 x 5.9 cm and require 200 micron thick silicon material due to mission weight constraints. Normalized values for open circuit voltage, short circuit current, and maximum power calculations derived from electron radiation testing are given. In addition, thermal alpha testing values of absorptivity and emittance are included. A pilot cell processing run produced cells averaging 14.4% efficiencies at AMO 28 C. Manufacturing for such cells will be on a mechanized process line, and the area of coverslide application technology must be considered in order to achieve cost effective production.

  14. Gunshot identification system by integration of open source consumer electronics

    NASA Astrophysics Data System (ADS)

    López R., Juan Manuel; Marulanda B., Jose Ignacio

    2014-05-01

    This work presents a prototype of low-cost gunshots identification system that uses consumer electronics in order to ensure the existence of gunshots and then classify it according to a previously established database. The implementation of this tool in the urban areas is to set records that support the forensics, hence improving law enforcement also on developing countries. An analysis of its effectiveness is presented in comparison with theoretical results obtained with numerical simulations.

  15. GaN Initiative for Grid Applications (GIGA)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Turner, George

    2015-07-03

    For nearly 4 ½ years, MIT Lincoln Laboratory (MIT/LL) led a very successful, DoE-funded team effort to develop GaN-on-Si materials and devices, targeting high-voltage (>1 kV), high-power, cost-effective electronics for grid applications. This effort, called the GaN Initiative for Grid Applications (GIGA) program, was initially made up of MIT/LL, the MIT campus group of Prof. Tomas Palacios (MIT), and the industrial partner M/A Com Technology Solutions (MTS). Later in the program a 4th team member was added (IQE MA) to provide commercial-scale GaN-on-Si epitaxial materials. A basic premise of the GIGA program was that power electronics, for ubiquitous utilization -evenmore » for grid applications - should be closer in cost structure to more conventional Si-based power electronics. For a number of reasons, more established GaN-on-SiC or even SiC-based power electronics are not likely to reach theses cost structures, even in higher manufacturing volumes. An additional premise of the GIGA program was that the technical focus would be on materials and devices suitable for operating at voltages > 1 kV, even though there is also significant commercial interest in developing lower voltage (< 1 kV), cost effective GaN-on-Si devices for higher volume applications, like consumer products. Remarkable technical progress was made during the course of this program. Advances in materials included the growth of high-quality, crack-free epitaxial GaN layers on large-diameter Si substrates with thicknesses up to ~5 μm, overcoming significant challenges in lattice mismatch and thermal expansion differences between Si and GaN in the actual epitaxial growth process. Such thick epilayers are crucial for high voltage operation of lateral geometry devices such as Schottky barrier (SB) diodes and high electron mobility transistors (HEMTs). New “Normally-Off” device architectures were demonstrated – for safe operation of power electronics circuits. The trade-offs between lateral and vertical devices were explored, with the conclusion that lateral devices are superior for fundamental thermal reasons, as well as for the demonstration of future generations of monolithic power circuits. As part of the materials and device investigations breakdown mechanisms in GaN-on-Si structures were fully characterized and effective electric field engineering was recognized as critical for achieving even higher voltage operation. Improved device contact technology was demonstrated, including the first gold-free metallizations (to enable processing in CMOS foundries) while maintaining low specific contact resistance needed for high-power operation and 5-order-of magnitude improvement in device leakage currents (essential for high power operation). In addition, initial GaN-on-Si epitaxial growth was performed on 8”/200 mm Si starting substrates.« less

  16. Introduction of an all-electronic administrative process for a major international pediatric surgical meeting.

    PubMed

    Applebaum, Harry; Boles, Kay; Atkinson, James B

    2003-12-01

    The administrative process for annual meetings is time consuming and increasingly costly when accomplished by traditional postal, fax, and telephone methods. The Pacific Association of Pediatric Surgeons introduced an all-electronic communication format for its 2002 annual meeting. Attendee acceptance and administrative and financial impact were evaluated. Interested physicians were directed to a Website containing detailed information and electronic forms. E-mail was used for the abstract selection and manuscript submission processes. Attendees were surveyed to evaluate the new format. Administrative costs for the new format were compared with estimated costs for a comparable traditionally managed meeting. Attendance was similar to that at previous US meetings. Eighty-two percent of respondents approved of the all-electronic format, although 48% believed a choice should remain. None suggested a complete return to the traditional format. Abstract and manuscript processing time was reduced substantially as were administrative costs (79.43 dollars savings per physician registrant). Adoption of an all-electronic annual meeting administrative process was associated with substantial cost reduction, increased efficiency, and excellent attendee satisfaction. This technology can help avoid increased registration fees while easing the burden on physician volunteers.

  17. Antenna Electronics Concept for the Next-Generation Very Large Array

    NASA Astrophysics Data System (ADS)

    Beasley, Anthony J.; Jackson, Jim; Selina, Robert

    2017-01-01

    The National Radio Astronomy Observatory (NRAO), in collaboration with its international partners, completed two major projects over the past decade: the sensitivity upgrade for the Karl Jansky Very Large Array (VLA) and the construction of the Atacama Large Millimeter/Sub-Millimeter Array (ALMA). The NRAO is now considering the scientific potential and technical feasibility of a next-generation VLA (ngVLA) with an emphasis on thermal imaging at milli-arcsecond resolution. The preliminary goals for the ngVLA are to increase both the system sensitivity and angular resolution of the VLA tenfold and to cover a frequency range of 1.2-116 GHz.A number of key technical challenges have been identified for the project. These include cost-effective antenna manufacturing (in the hundreds), suitable wide-band feed and receiver designs, broad-band data transmission, and large-N correlators. Minimizing the overall operations cost is also a fundamental design requirement.The designs of the antenna electronics, reference distribution system, and data transmission system are anticipated to be major construction and operations cost drivers for the facility. The electronics must achieve a high level of performance, while maintaining low operation and maintenance costs and a high level of reliability. Additionally, due to the uncertainty in the feasibility of wideband receivers, advancements in digitizer technology, and budget constraints, the hardware system architecture should be scalable to the number of receiver bands and the speed and resolution of available digitizers.Here, we present the projected performance requirements of the ngVLA, a proposed block diagram for the instrument’s electronics systems, parameter tradeoffs within the system specifications, and areas of technical risk where technical advances may be required for successful production and installation.

  18. HED-TIE: A wafer-scale approach for fabricating hybrid electronic devices with trench isolated electrodes

    NASA Astrophysics Data System (ADS)

    Banerjee, Sreetama; Bülz, Daniel; Solonenko, Dmytro; Reuter, Danny; Deibel, Carsten; Hiller, Karla; Zahn, Dietrich R. T.; Salvan, Georgeta

    2017-05-01

    Organic-inorganic hybrid electronic devices (HEDs) offer opportunities for functionalities that are not easily obtainable with either organic or inorganic materials individually. In the strive for down-scaling the channel length in planar geometry HEDs, the best results were achieved with electron beam lithography or nanoimprint lithography. Their application on the wafer level is, however, cost intensive and time consuming. Here, we propose trench isolated electrode (TIE) technology as a fast, cost effective, wafer-level approach for the fabrication of planar HEDs with electrode gaps in the range of 100 nm. We demonstrate that the formation of the organic channel can be realized by deposition from solution as well as by the thermal evaporation of organic molecules. To underline one key feature of planar HED-TIEs, namely full accessibility of the active area of the devices by external stimuli such as light, 6,13-bis (triisopropylsilylethynyl) (TIPS)-pentacene/Au HED-TIEs are successfully tested for possible application as hybrid photodetectors in the visible spectral range.

  19. Cost-utility analysis of intravenous immunoglobulin for the treatment of steroid-refractory dermatomyositis in Thailand.

    PubMed

    Bamrungsawad, Naruemon; Chaiyakunapruk, Nathorn; Upakdee, Nilawan; Pratoomsoot, Chayanin; Sruamsiri, Rosarin; Dilokthornsakul, Piyameth

    2015-05-01

    Intravenous immunoglobulin (IVIG) has been shown to be effective in treating steroid-refractory dermatomyositis (DM). There remains no evidence of its cost-effectiveness in Thailand. Our objective was to estimate the cost utility of IVIG as a second-line therapy in steroid-refractory DM in Thailand. A Markov model was developed to estimate the relevant costs and health benefits for IVIG plus corticosteroids in comparison with immunosuppressant plus corticosteroids in steroid-refractory DM from a societal perspective over a patient's lifetime. The effectiveness and utility parameters were obtained from clinical literature, meta-analyses, medical record reviews, and patient interviews, whereas cost data were obtained from an electronic hospital database and patient interviews. Costs are presented in $US, year 2012 values. All future costs and outcomes were discounted at a rate of 3% per annum. One-way and probabilistic sensitivity analyses were also performed. Over a lifetime horizon, the model estimated treatment under IVIG plus corticosteroids to be cost saving compared with immunosuppressant plus corticosteroids, where the saving of costs and incremental quality-adjusted life-years (QALYs) were $US4738.92 and 1.96 QALYs, respectively. Sensitivity analyses revealed that probability of response of immunosuppressant plus corticosteroids was the most influential parameter on incremental QALYs and costs. At a societal willingness-to-pay threshold in Thailand of $US5148 per QALY gained, the probability of IVIG being cost effective was 97.6%. The use of IVIG plus corticosteroids is cost saving compared with treatment with immunosuppressant plus corticosteroids in Thai patients with steroid-refractory DM. Policy makers should consider using our findings in their decision-making process for adding IVIG to corticosteroids as the second-line therapy for steroid-refractory DM patients.

  20. Ionospheric effects of the simultaneous occurrence of a solar proton event and relativistic electron precipitation as recorded by ground-based instruments at different latitudes

    NASA Astrophysics Data System (ADS)

    Shirochkov, A. V.; Makarova, L. N.; Sokolov, S. N.; Sheldon, W. R.

    2004-08-01

    The intense event of highly relativistic electron (HRE) precipitation of May 1992 has been analyzed using data from ground-based observations (riometers and VLF phase measurements). Special attention was given to some features of this event observed at high and very high geomagnetic latitudes, since this aspect of the event was not well documented in previous studies. A remarkable feature of the HRE event of May 1992 was the simultaneous occurrence of a strong solar proton event (SPE), although reliable evidence shows that the simultaneous appearance of SPE and HRE events is not unique. It was demonstrated that a meridian chain of riometers with high latitudinal resolution is an effective and low-cost (as compared with satellite observations) tool to separate the effects of solar proton and relativistic electrons in the lower ionosphere. A significant conclusion is that the polar cap area is free from relativistic electron precipitation. Other interesting aspects of this complex geophysical phenomenon are also discussed.

  1. A Systematic Review and Narrative Synthesis of Health Economic Studies Conducted for Hereditary Haemochromatosis.

    PubMed

    de Graaff, Barbara; Neil, Amanda; Sanderson, Kristy; Si, Lei; Yee, Kwang Chien; Palmer, Andrew J

    2015-10-01

    Hereditary haemochromatosis (HH) is a common genetic condition amongst people of northern European heritage. HH is associated with increased iron absorption leading to parenchymal organ damage and multiple arthropathies. Early diagnosis and treatment prevents complications. Population screening may increase early diagnosis, but no programmes have been introduced internationally: a paucity of health economic data is often cited as a barrier. To conduct a systematic review of all health economic studies in HH. Studies were identified through electronic searching of economic/biomedical databases. Any study on HH with original economic component was included. Study quality was formally assessed. Health economic data were extracted and analysed through narrative synthesis. Thirty-eight studies met the inclusion criteria. The majority of papers reported on costs or cost effectiveness of screening programmes. Whilst most concluded screening was cost effective compared with no screening, methodological flaws limit the quality of these findings. Assumptions regarding clinical penetrance, effectiveness of screening, health-state utility values (HSUVs), exclusion of early symptomatology (such as fatigue, lethargy and multiple arthropathies) and quantification of costs associated with HH were identified as key limitations. Treatment studies concluded therapeutic venepuncture was the most cost-effective intervention. There is a paucity of high-quality health economic studies relating to HH. The development of a comprehensive HH cost-effectiveness model utilising HSUVs is required to determine whether screening is worthwhile.

  2. Staging Options for the Air Force’s Electronic Combat Test Capability: a Cost Analysis

    DTIC Science & Technology

    1990-09-01

    strategic in nature and completely different than daily operating decisions (20:6). Horngren , in his book Cost Accounting : A Managerial Emphasis...AFIT/GCA/LSY/90S-3 DTTC S E-191 J) C, STAGING OPTIONS FOR THE AIR FORCE’S ELECTRONIC COMBAT TEST CAPABILITY: A COST ANALYSIS THESIS Joseph J. Landino...Alternative Costs ......... 56 v AFIT/GCA/LSY/90S-3 Abstract This study’s purpose was to identify the lowest cost aircraft staging base( s ) for the Air

  3. Retrospective return on investment analysis of an electronic treatment adherence device piloted in the Northern Cape Province.

    PubMed

    Broomhead, Sean; Mars, Maurice

    2012-01-01

    The return on investment (ROI) for utilizing the SIMpill electronic treatment adherence solution as an adjunct to directly observed treatment short-course (DOTS) is assessed using data from a 2005 pilot of the SIMpill solution among new smear-positive tuberculosis (TB) patients in the Northern Cape Province. The value of this cost minimization analysis (CMA), for use by public health planners in low-resource settings as a precursor to more rigorous assessment, is discussed. The retrospective analysis compares the costs and health outcomes of the DOTS-SIMpill cohort with DOTS-only controls. Hypothetical 5-year cash flows are generated and discounted to estimate net present values (NPVs). Comparison between the DOTS-SIMpill pilot cohort and DOTS-only supported controls, for a hypothetical implementation of 1,000 devices, over 5 years, demonstrates positive ROI for the DOTS-SIMpill cohort based on improved health outcomes and reduced average cost per patient. The net stream is shown to be positive from the first year. Discounted NPV is ZAR 3,255,256 (US$ 493,221) for a cohort that would have started mid 2005 and ZAR 3,747,636 (US$ 487,339) starting mid 2010. This is an ROI of 23% over the 5-year period. The addition of electronic treatment adherence support technology can help to improve TB outcomes and lower average cost per patient by reducing treatment failure and the associated higher cost and burden on limited resources. CMA is an appropriate initial analysis for health planners to highlight options that may justify more sophisticated methods such as cost effectiveness analysis or full cost benefit analysis where a preferred option is immediately revealed. CMA is proposed as a tool for use by public health planners in low-resource settings to evaluate the ROI of treatment adherence technology postpilot and prior to implementation.

  4. Grain-size considerations for optoelectronic multistage interconnection networks.

    PubMed

    Krishnamoorthy, A V; Marchand, P J; Kiamilev, F E; Esener, S C

    1992-09-10

    This paper investigates, at the system level, the performance-cost trade-off between optical and electronic interconnects in an optoelectronic interconnection network. The specific system considered is a packet-switched, free-space optoelectronic shuffle-exchange multistage interconnection network (MIN). System bandwidth is used as the performance measure, while system area, system power, and system volume constitute the cost measures. A detailed design and analysis of a two-dimensional (2-D) optoelectronic shuffle-exchange routing network with variable grain size K is presented. The architecture permits the conventional 2 x 2 switches or grains to be generalized to larger K x K grain sizes by replacing optical interconnects with electronic wires without affecting the functionality of the system. Thus the system consists of log(k) N optoelectronic stages interconnected with free-space K-shuffles. When K = N, the MIN consists of a single electronic stage with optical input-output. The system design use an effi ient 2-D VLSI layout and a single diffractive optical element between stages to provide the 2-D K-shuffle interconnection. Results indicate that there is an optimum range of grain sizes that provides the best performance per cost. For the specific VLSI/GaAs multiple quantum well technology and system architecture considered, grain sizes larger than 256 x 256 result in a reduced performance, while grain sizes smaller than 16 x 16 have a high cost. For a network with 4096 channels, the useful range of grain sizes corresponds to approximately 250-400 electronic transistors per optical input-output channel. The effect of varying certain technology parameters such as the number of hologram phase levels, the modulator driving voltage, the minimum detectable power, and VLSI minimum feature size on the optimum grain-size system is studied. For instance, results show that using four phase levels for the interconnection hologram is a good compromise for the cost functions mentioned above. As VLSI minimum feature sizes decrease, the optimum grain size increases, whereas, if optical interconnect performance in terms of the detector power or modulator driving voltage requirements improves, the optimum grain size may be reduced. Finally, several architectural modifications to the system, such as K x K contention-free switches and sorting networks, are investigated and optimized for grain size. Results indicate that system bandwidth can be increased, but at the price of reduced performance/cost. The optoelectronic MIN architectures considered thus provide a broad range of performance/cost alternatives and offer a superior performance over purely electronic MIN's.

  5. Cost-effectiveness of food, supplement and environmental interventions to address malnutrition in residential aged care: a systematic review.

    PubMed

    Hugo, Cherie; Isenring, Elisabeth; Miller, Michelle; Marshall, Skye

    2018-05-01

    observational studies have shown that nutritional strategies to manage malnutrition may be cost-effective in aged care; but more robust economic data is needed to support and encourage translation to practice. Therefore, the aim of this systematic review is to compare the cost-effectiveness of implementing nutrition interventions targeting malnutrition in aged care homes versus usual care. residential aged care homes. systematic literature review of studies published between January 2000 and August 2017 across 10 electronic databases. Cochrane Risk of Bias tool and GRADE were used to evaluate the quality of the studies. eight included studies (3,098 studies initially screened) reported on 11 intervention groups, evaluating the effect of modifications to dining environment (n = 1), supplements (n = 5) and food-based interventions (n = 5). Interventions had a low cost of implementation (<£2.30/resident/day) and provided clinical improvement for a range of outcomes including weight, nutritional status and dietary intake. Supplements and food-based interventions further demonstrated a low cost per quality adjusted life year or unit of physical function improvement. GRADE assessment revealed the quality of the body of evidence that introducing malnutrition interventions, whether they be environmental, supplements or food-based, are cost-effective in aged care homes was low. this review suggests supplements and food-based nutrition interventions in the aged care setting are clinically effective, have a low cost of implementation and may be cost-effective at improving clinical outcomes associated with malnutrition. More studies using well-defined frameworks for economic analysis, stronger study designs with improved quality, along with validated malnutrition measures are needed to confirm and increase confidence with these findings.

  6. Economic evaluation of exercise-based cardiac rehabilitation in patients with a recent acute coronary syndrome.

    PubMed

    Hautala, A J; Kiviniemi, A M; Mäkikallio, T; Koistinen, P; Ryynänen, O-P; Martikainen, J A; Seppänen, T; Huikuri, H V; Tulppo, M P

    2017-11-01

    Health care decision-making requires evidence of the cost-effectiveness of medical therapies. We evaluated the cost-effectiveness of exercise-based cardiac rehabilitation (ECR) implemented according to guidelines. All the patients (n = 204) had experienced a recent acute coronary syndrome and were randomized to a 1-year ECR (n = 109) or usual care (UC) group (n = 95). The patients' health-related quality of life was followed using the 15D instrument and health care costs were collected from electronic health registries. The cost-effectiveness of ECR was estimated based on intervention and health care costs and quality-adjusted life years (QALYs) gained. The total average cost per patient was lower in ECR than in UC. The incremental cost was divided by the baseline-adjusted incremental QALYs (0.045), yielding an incremental cost-effectiveness ratio of -€24511/QALYs. A combined endpoint of mortality, recurrent coronary event, or hospitalization for a heart failure occurred for five patients in ECR and 16 patients in UC (HR 3.9, 95% CI 1.4-10.6, P = 0.004, relative risk reduction 73%, number needed to treat eight). ECR is a dominant treatment option and decreases the occurrence of adverse cardiac events. These results are useful for decision-making when planning optimal utilization of resources in Finnish health care. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Fully inkjet-printed two-dimensional material field-effect heterojunctions for wearable and textile electronics.

    PubMed

    Carey, Tian; Cacovich, Stefania; Divitini, Giorgio; Ren, Jiesheng; Mansouri, Aida; Kim, Jong M; Wang, Chaoxia; Ducati, Caterina; Sordan, Roman; Torrisi, Felice

    2017-10-31

    Fully printed wearable electronics based on two-dimensional (2D) material heterojunction structures also known as heterostructures, such as field-effect transistors, require robust and reproducible printed multi-layer stacks consisting of active channel, dielectric and conductive contact layers. Solution processing of graphite and other layered materials provides low-cost inks enabling printed electronic devices, for example by inkjet printing. However, the limited quality of the 2D-material inks, the complexity of the layered arrangement, and the lack of a dielectric 2D-material ink able to operate at room temperature, under strain and after several washing cycles has impeded the fabrication of electronic devices on textile with fully printed 2D heterostructures. Here we demonstrate fully inkjet-printed 2D-material active heterostructures with graphene and hexagonal-boron nitride (h-BN) inks, and use them to fabricate all inkjet-printed flexible and washable field-effect transistors on textile, reaching a field-effect mobility of ~91 cm 2  V -1  s -1 , at low voltage (<5 V). This enables fully inkjet-printed electronic circuits, such as reprogrammable volatile memory cells, complementary inverters and OR logic gates.

  8. Low-Cost Inkjet Printing Technology for the Rapid Prototyping of Transducers

    PubMed Central

    Andò, Bruno; Baglio, Salvatore; Bulsara, Adi R.; Emery, Teresa; Marletta, Vincenzo; Pistorio, Antonio

    2017-01-01

    Recently, there has been an upsurge in efforts dedicated to developing low-cost flexible electronics by exploiting innovative materials and direct printing technologies. This interest is motivated by the need for low-cost mass-production, shapeable, and disposable devices, and the rapid prototyping of electronics and sensors. This review, following a short overview of main printing processes, reports examples of the development of flexible transducers through low-cost inkjet printing technology. PMID:28368318

  9. Incremental Costs and Cost Effectiveness of Intensive Treatment in Individuals with Type 2 Diabetes Detected by Screening in the ADDITION-UK Trial: An Update with Empirical Trial-Based Cost Data.

    PubMed

    Laxy, Michael; Wilson, Edward C F; Boothby, Clare E; Griffin, Simon J

    2017-12-01

    There is uncertainty about the cost effectiveness of early intensive treatment versus routine care in individuals with type 2 diabetes detected by screening. To derive a trial-informed estimate of the incremental costs of intensive treatment as delivered in the Anglo-Danish-Dutch Study of Intensive Treatment in People with Screen-Detected Diabetes in Primary Care-Europe (ADDITION) trial and to revisit the long-term cost-effectiveness analysis from the perspective of the UK National Health Service. We analyzed the electronic primary care records of a subsample of the ADDITION-Cambridge trial cohort (n = 173). Unit costs of used primary care services were taken from the published literature. Incremental annual costs of intensive treatment versus routine care in years 1 to 5 after diagnosis were calculated using multilevel generalized linear models. We revisited the long-term cost-utility analyses for the ADDITION-UK trial cohort and reported results for ADDITION-Cambridge using the UK Prospective Diabetes Study Outcomes Model and the trial-informed cost estimates according to a previously developed evaluation framework. Incremental annual costs of intensive treatment over years 1 to 5 averaged £29.10 (standard error = £33.00) for consultations with general practitioners and nurses and £54.60 (standard error = £28.50) for metabolic and cardioprotective medication. For ADDITION-UK, over the 10-, 20-, and 30-year time horizon, adjusted incremental quality-adjusted life-years (QALYs) were 0.014, 0.043, and 0.048, and adjusted incremental costs were £1,021, £1,217, and £1,311, resulting in incremental cost-effectiveness ratios of £71,232/QALY, £28,444/QALY, and £27,549/QALY, respectively. Respective incremental cost-effectiveness ratios for ADDITION-Cambridge were slightly higher. The incremental costs of intensive treatment as delivered in the ADDITION-Cambridge trial were lower than expected. Given UK willingness-to-pay thresholds in patients with screen-detected diabetes, intensive treatment is of borderline cost effectiveness over a time horizon of 20 years and more. Copyright © 2017. Published by Elsevier Inc.

  10. 75 FR 12483 - Courtesy Notice of Liquidation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-16

    .... Currently, CBP provides an electronic and a paper courtesy notice for importers of record whose entry... notification process and reduce printing and mailing costs, CBP proposes to discontinue mailing paper courtesy... that relate to the economic, environmental, or federalism effects that might result from this proposed...

  11. Factors affecting hospital costs in lung cancer patients in the United Kingdom.

    PubMed

    Kennedy, Martyn P T; Hall, Peter S; Callister, Matthew E J

    2016-07-01

    Rising healthcare costs and financial constraints are increasing pressure on healthcare budgets. There is little published data on the healthcare costs of lung cancer in the UK, with international studies mostly small and limited by data collection methods. Accurate assessment of healthcare costs is essential for effective service planning. We conducted a retrospective, descriptive cohort study linking clinical data from a local electronic database of lung cancer patients at a large UK teaching hospital with recorded hospital income. Costs were adjusted to 2013-2014 prices. The study analysed secondary care costs of 3274 patients. Mean cumulative costs were £5852 (95% CI, £5694 to £6027) at 90 days and £10,009 (95% CI, £9717 to £10,278) at one year. The majority of costs (58.5%) were accumulated within the first 90 days, with acute inpatient costs the largest contributor at one year (42.1%). The strongest predictor of costs was active treatment, especially surgery. Costs were also affected by age, route to diagnosis, clinical stage and cell type. Successful early diagnosis initiatives that increase radical treatment rates and improve outcomes may significantly increase the secondary care costs of lung cancer management. The use of routine NHS clinical and financial data can enable efficient and effective analyses of large cohort health economic data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Cost-effectiveness of health-related lifestyle advice delivered by peer or lay advisors: synthesis of evidence from a systematic review

    PubMed Central

    2013-01-01

    Background Development of new peer or lay health-related lifestyle advisor (HRLA) roles is one response to the need to enhance public engagement in, and improve cost-effectiveness of, health improvement interventions. This article synthesises evidence on the cost-effectiveness of HRLA interventions aimed at adults in developed countries, derived from the first systematic review of the effectiveness, cost-effectiveness, equity and acceptability of different types of HRLA role. Methods The best available evidence on the cost-effectiveness of HRLA interventions was obtained using systematic searches of 20 electronic databases and key journals, as well as searches of the grey literature and the internet. Interventions were classified according to the primary health behaviour targeted and intervention costs were estimated where necessary. Lifetime health gains were estimated (in quality-adjusted life years, where possible), based on evidence of effectiveness of HRLAs in combination with published estimates of the lifetime health gains resulting from lifestyle changes, and assumptions over relapse. Incremental cost-effectiveness ratios are reported. Results Evidence of the cost-effectiveness of HRLAs was identified from 24 trials included in the systematic review. The interventions were grouped into eight areas. We found little evidence of effectiveness of HRLAs for promotion of exercise/improved diets. Where HRLAs were effective cost-effectiveness varied considerably: Incremental Cost effectiveness Ratios were estimated at £6,000 for smoking cessation; £14,000 for a telephone based type 2 diabetes management; and £250,000 or greater for promotion of mammography attendance and for HIV prevention amongst drug users. We lacked sufficient evidence to estimate ICERs for breastfeeding promotion and mental health promotion, or to assess the impact of HRLAs on health inequalities. Conclusions Overall, there is limited evidence suggesting that HRLAs are cost-effective in terms of changing health-related knowledge, behaviours or health outcomes. The evidence that does exist indicates that HRLAs are only cost-effective when they target behaviours likely to have a large impact on overall health-related quality of life. Further development of HRLA interventions needs to target specific population health needs where potential exists for significant improvement, and include rigorous evaluation to ensure that HRLAs provide sufficient value for money. PMID:24304826

  13. Final Scientific/Technical Report (DE-FG02-05ER46201)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Car, Roberto

    The research supported by this grant focused on the quantum mechanical theory of the electrons in materials and molecules. Progress was made in dealing with electronic correlation effects in the ground state energy of molecular systems, and with topological concepts to classify the electronic state of molecules and materials, including excitation and transport properties. The physical and chemical properties of molecules and materials derive from their electronic structure, but the latter cannot be calculated exactly even with the most powerful computers because the computational cost of solving the exact equations of quantum mechanics increases exponentially with the number of electrons.more » The exponential cost originates from the correlations among the electrons that repel each other via Coulombic forces. In this project we have developed a new functional approximation for the ground state electronic energy that includes explicitly, and in a controllable way, the effects of the interelectronic correlations. In addition we have further developed topological concepts for classifying the electronic states of periodic ring molecules and solids. Topological concepts are very powerful because they allow us to predict subtle properties of materials and molecules using very general geometrical properties of the electron wavefunctions that do not depend on the quantitative details of the electronic interactions, which are very difficult to calculate with high accuracy. The development of a new class of controlled functional approximations for the ground state energy of molecules and materials was the main goal of the project. It has been fulfilled with the formulation of the occupation-probabilities natural orbital functional theory (OP-NOFT). This approach introduces new theoretical concepts but practical application has proved to be harder than anticipated. So far it has been utilized only at its lowest level of approximation in the context of relatively small molecules (with up to 16 atoms). The study of topological properties of the electron wavefunctions in materials was not proposed in the original proposal but was prompted during the funding period by our interaction with leading experimental groups in materials chemistry and physics at Princeton University.« less

  14. Economic Evaluation of Occupational Safety and Health Interventions From the Employer Perspective

    PubMed Central

    Grimani, Aikaterini; Bergström, Gunnar; Casallas, Martha Isabel Riaño; Aboagye, Emmanuel; Jensen, Irene; Lohela-Karlsson, Malin

    2018-01-01

    Objectives: The aim of this systematic review was to evaluate the cost-effectiveness of occupational safety and health interventions from the employer perspective. Methods: A comprehensive literature search (2005 to 2016) in five electronic databases was conducted. Pre-2005 studies were identified from the reference lists of previous studies and systematic reviews, which have similar objective to those of this search. Results: A total of 19 randomized controlled trials and quasi-experimental studies were included, targeting diverse health problems in a number of settings. Few studies included organizational-level interventions. When viewed in relation to the methodological quality and the sufficiency of economic evidence, five of 11 cost-effective occupational safety and health (OSH) interventions appear to be promising. Conclusion: The present systematic review highlights the need for high-quality economic evidence to evaluate the cost-effectiveness of OSH interventions, especially at organizational-level, in all areas of worker health. PMID:29112631

  15. Systematic Review of Economic Evaluation of Laparotomy versus Laparoscopy for Patients Submitted to Roux-en-Y Gastric Bypass

    PubMed Central

    Sussenbach, Samanta Pereira; Silva, Everton Nunes; Pufal, Milene Amarante; Casagrande, Daniela Shan; Padoin, Alexandre Vontobel; Mottin, Cláudio Corá

    2014-01-01

    Background Because of the high prevalence of obesity, there is a growing demand for bariatric surgery worldwide. The objective of this systematic review was to analyze the difference in relation to cost-effectiveness of access route by laparoscopy versus laparotomy of Roux en-Y gastric bypass (RYGB). Methods A systematic review was conducted in the electronic databases MEDLINE, Embase, Scopus, Cochrane and Lilacs in order to identify economic evaluation studies that compare the cost-effectiveness of laparoscopic and laparotomic routes in RYGB. Results In a total of 494 articles, only 6 fulfilled the eligibility criteria. All studies were published between 2001 and 2008 in the United States (USA). Three studies fulfilled less than half of the items that evaluated the results quality; two satisfied 5 of the required items, and only 1 study fulfilled 7 of 10 items. The economic evaluation of studies alternated between cost-effectiveness and cost-consequence. Five studies considered the surgery by laparoscopy the dominant strategy, because it showed greater clinical benefit (less probability of post-surgical complications, less hospitalization time) and lower total cost. Conclusion This review indicates that laparoscopy is a safe and well-tolerated technique, despite the costs of surgery being higher when compared with laparotomy. However, the additional costs are compensated by the lower probability of complications after surgery and, consequently, avoiding their costs. PMID:24945704

  16. Advanced Polymers for Practical Use

    NASA Technical Reports Server (NTRS)

    1999-01-01

    Resulting from a SBIR contract with the Goddard Space Flight Center, Foster-Miller developed a high performance, low cost substrate for printed circuits with a coefficient of thermal expansion (CTE) matched to the surface mounted devices. The commercial product that resulted from the agreement between the two organizations was so successful that Foster-Miller created a spin-off company named Superex, Inc., devoted solely to the promotion of this particular substrate. The contract originated from NASA's need to develop better, more cost effective satellite and land based electronic applications.

  17. Air Force Manufacturing Technology Electronics Program, FY72-FY85.

    DTIC Science & Technology

    1985-04-01

    magnetic films of the composition Yl.52 EuO.30 TmO.30 CaO.88 Fe4.12 012 on 1.5 inch and 2.0 inch gadolinium gallium garnet substrates. Ten film were...volume manufacturing of hybrid MIC’s. A systematic integrated cost effective approach to testing, trimming/matching, fabri - cation, and assembly is...ESTABLISH MANUFACTURING METHODS FOR LOW COST HIGH RELIABILITY FABRI - CATION AND ACTIVATION OF OXIDE CATHODES FOR USE IN SPACE TRAVELING WAVE TUBES

  18. The economics of health information technology in medication management: a systematic review of economic evaluations

    PubMed Central

    Tarride, Jean-Eric; Goeree, Ron; Lokker, Cynthia; McKibbon, K Ann

    2011-01-01

    Objective To conduct a systematic review and synthesis of the evidence surrounding the cost-effectiveness of health information technology (HIT) in the medication process. Materials and methods Peer-reviewed electronic databases and gray literature were searched to identify studies on HIT used to assist in the medication management process. Articles including an economic component were reviewed for further screening. For this review, full cost-effectiveness analyses, cost-utility analyses and cost-benefit analyses, as well as cost analyses, were eligible for inclusion and synthesis. Results The 31 studies included were heterogeneous with respect to the HIT evaluated, setting, and economic methods used. Thus the data could not be synthesized, and a narrative review was conducted. Most studies evaluated computer decision support systems in hospital settings in the USA, and only five of the studied performed full economic evaluations. Discussion Most studies merely provided cost data; however, useful economic data involves far more input. A full economic evaluation includes a full enumeration of the costs, synthesized with the outcomes of the intervention. Conclusion The quality of the economic literature in this area is poor. A few studies found that HIT may offer cost advantages despite their increased acquisition costs. However, given the uncertainty that surrounds the costs and outcomes data, and limited study designs, it is difficult to reach any definitive conclusion as to whether the additional costs and benefits represent value for money. Sophisticated concurrent prospective economic evaluations need to be conducted to address whether HIT interventions in the medication management process are cost-effective. PMID:21984590

  19. Behavioral Economics Interventions to Improve Outpatient Antibiotic Prescribing for Acute Respiratory Infections: a Cost-Effectiveness Analysis.

    PubMed

    Gong, Cynthia L; Zangwill, Kenneth M; Hay, Joel W; Meeker, Daniella; Doctor, Jason N

    2018-05-08

    Behavioral economics interventions have been shown to effectively reduce the rates of inappropriate antibiotic prescriptions for acute respiratory infections (ARIs). To determine the cost-effectiveness of three behavioral economic interventions designed to reduce inappropriate antibiotic prescriptions for ARIs. Thirty-year Markov model from the US societal perspective with inputs derived from the literature and CDC surveillance data. Forty-five-year-old adults with signs and symptoms of ARI presenting to a healthcare provider. (1) Provider education on guidelines for the appropriate treatment of ARIs; (2) Suggested Alternatives, which utilizes computerized clinical decision support to suggest non-antibiotic treatment choices in lieu of antibiotics; (3) Accountable Justification, which mandates free-text justification into the patient's electronic health record when antibiotics are prescribed; and (4) Peer Comparison, which sends a periodic email to prescribers about his/her rate of inappropriate antibiotic prescribing relative to clinician colleagues. Discounted costs, quality-adjusted life years (QALYs), and incremental cost-effectiveness ratios. Each intervention has lower costs but higher QALYs compared to provider education. Total costs for each intervention were $178.21, $173.22, $172.82, and $172.52, and total QALYs were 14.68, 14.73, 14.74, and 14.74 for the control, Suggested Alternatives, Accountable Justification, and Peer Comparison groups, respectively. Results were most sensitive to the quality-of-life of the uninfected state, and the likelihood and costs for antibiotic-associated adverse events. Behavioral economics interventions can be cost-effective strategies for reducing inappropriate antibiotic prescriptions by reducing healthcare resource utilization.

  20. The Kaiser Permanente implant registries: effect on patient safety, quality improvement, cost effectiveness, and research opportunities.

    PubMed

    Paxton, Elizabeth W; Inacio, Maria Cs; Kiley, Mary-Lou

    2012-01-01

    Considering the high cost, volume, and patient safety issues associated with medical devices, monitoring of medical device performance is critical to ensure patient safety and quality of care. The purpose of this article is to describe the Kaiser Permanente (KP) implant registries and to highlight the benefits of these implant registries on patient safety, quality, cost effectiveness, and research. Eight KP implant registries leverage the integrated health care system's administrative databases and electronic health records system. Registry data collected undergo quality control and validation as well as statistical analysis. Patient safety has been enhanced through identification of affected patients during major recalls, identification of risk factors associated with outcomes of interest, development of risk calculators, and surveillance programs for infections and adverse events. Effective quality improvement activities included medical center- and surgeon-specific profiles for use in benchmarking reports, and changes in practice related to registry information output. Among the cost-effectiveness strategies employed were collaborations with sourcing and contracting groups, and assistance in adherence to formulary device guidelines. Research studies using registry data included postoperative complications, resource utilization, infection risk factors, thromboembolic prophylaxis, effects of surgical delay on concurrent injuries, and sports injury patterns. The unique KP implant registries provide important information and affect several areas of our organization, including patient safety, quality improvement, cost-effectiveness, and research.

  1. Rapid localized deactivation of self-assembled monolayers by propagation-controlled laser-induced plasma and its application to self-patterning of electronics and biosensors

    NASA Astrophysics Data System (ADS)

    Kim, Jongsu; Kwon, Seung-Gab; Back, Seunghyun; Kang, Bongchul

    2018-03-01

    We present a novel laser-induced surface treatment process to rapidly control the spatial wettabilities of various functional solutions with submicron to micron resolutions. Ultrathin hydrophobic self-assembled monolayers (SAMs) that little absorb typical laser lights due to short penetration depth were selectively deactivated by instantaneous interaction with laser-induced metallic plasmas. The spatial region of the deactivated SAM, which corresponds to process resolution, is adjustable by controlling the spatial propagation of the plasma. This method leads to the parallel formation of hydrophilic functional solutions on glass substrates with a minimum resolution on the submicron scale. To show its feasibility in device engineering fields, this method was applied to the cost-effective fabrication of electronics and biosensors. Rapid self-patterning of electronic and biological functional solutions (silver nanoparticle solution and streptavidin protein solution) was successfully realized by selective deactivation of two different SAMs (tridecafluoro-1,1,2,2-tetrahydrooctyltrichlorosilane (FOTS) for electronics and the hetero-hybrid SAM (octadecyltrichlorosilane (OTS)/2-[methoxy(polyethyleneoxy)propyl] trichlorosilane (PEG)) for biosensors). As a result, this method can be exploited for the rapid and low-cost fabrication of various thin film devices such as electronics, biosensors, energy, displays, and photonics.

  2. A photovoltaic device structure based on internal electron emission.

    PubMed

    McFarland, Eric W; Tang, Jing

    2003-02-06

    There has been an active search for cost-effective photovoltaic devices since the development of the first solar cells in the 1950s (refs 1-3). In conventional solid-state solar cells, electron-hole pairs are created by light absorption in a semiconductor, with charge separation and collection accomplished under the influence of electric fields within the semiconductor. Here we report a multilayer photovoltaic device structure in which photon absorption instead occurs in photoreceptors deposited on the surface of an ultrathin metal-semiconductor junction Schottky diode. Photoexcited electrons are transferred to the metal and travel ballistically to--and over--the Schottky barrier, so providing the photocurrent output. Low-energy (approximately 1 eV) electrons have surprisingly long ballistic path lengths in noble metals, allowing a large fraction of the electrons to be collected. Unlike conventional cells, the semiconductor in this device serves only for majority charge transport and separation. Devices fabricated using a fluorescein photoreceptor on an Au/TiO2/Ti multilayer structure had typical open-circuit photovoltages of 600-800 mV and short-circuit photocurrents of 10-18 micro A cm(-2) under 100 mW cm(-2) visible band illumination: the internal quantum efficiency (electrons measured per photon absorbed) was 10 per cent. This alternative approach to photovoltaic energy conversion might provide the basis for durable low-cost solar cells using a variety of materials.

  3. Effect of iron doping on structural and microstructural properties of nanocrystalline ZnSnO3 thin films prepared by spray pyrolysis techniques

    NASA Astrophysics Data System (ADS)

    Pathan, Idris G.; Suryawanshi, Dinesh N.; Bari, Anil R.; Patil, Lalchand A.

    2018-05-01

    This work presents the effect of iron doping having different volume ratios (1 ml, 2.5 ml and 5 ml) on the structural, microstructural and electrical properties of zinc stannate thin films, prepared by spray pyrolysis method. These properties were characterized with X-ray diffraction (XRD) and Transmission Electron Microscope (TEM). In our study, XRD pattern indicates that ZnSnO3 has a perovskite phase with face exposed hexahedron structure. The electron diffraction fringes observed are in consistent with the peak observed in XRD patterns. Moreover the sensor reported in our study is cost-effective, user friendly and easy to fabricate.

  4. A hydrogel capsule as gate dielectric in flexible organic field-effect transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dumitru, L. M.; Manoli, K.; Magliulo, M.

    2015-01-01

    A jellified alginate based capsule serves as biocompatible and biodegradable electrolyte system to gate an organic field-effect transistor fabricated on a flexible substrate. Such a system allows operating thiophene based polymer transistors below 0.5 V through an electrical double layer formed across an ion-permeable polymeric electrolyte. Moreover, biological macro-molecules such as glucose-oxidase and streptavidin can enter into the gating capsules that serve also as delivery system. An enzymatic bio-reaction is shown to take place in the capsule and preliminary results on the measurement of the electronic responses promise for low-cost, low-power, flexible electronic bio-sensing applications using capsule-gated organic field-effect transistors.

  5. Clinical and cost-effectiveness of non-medical prescribing: A systematic review of randomised controlled trials

    PubMed Central

    Marriott, John; Graham-Clarke, Emma; Shirley, Debra; Rushton, Alison

    2018-01-01

    Objective To evaluate the clinical and cost-effectiveness of non-medical prescribing (NMP). Design Systematic review. Two reviewers independently completed searches, eligibility assessment and assessment of risk of bias. Data sources Pre-defined search terms/combinations were utilised to search electronic databases. In addition, hand searches of reference lists, key journals and grey literature were employed alongside consultation with authors/experts. Eligibility criteria for included studies Randomised controlled trials (RCTs) evaluating clinical or cost-effectiveness of NMP. Measurements reported on one or more outcome(s) of: pain, function, disability, health, social impact, patient-safety, costs-analysis, quality adjusted life years (QALYs), patient satisfaction, clinician perception of clinical and functional outcomes. Results Three RCTs from two countries were included (n = 932 participants) across primary and tertiary care settings. One RCT was assessed as low risk of bias, one as high risk of bias and one as unclear risk of bias. All RCTs evaluated clinical effectiveness with one also evaluating cost-effectiveness. Clinical effectiveness was evaluated using a range of safety and patient-reported outcome measures. Participants demonstrated significant improvement in outcomes when receiving NMP compared to treatment as usual (TAU) in all RCTs. An associated cost analysis showed NMP to be more expensive than TAU (regression coefficient p = 0.0000), however experimental groups generated increased QALYs compared to TAU. Conclusion Limited evidence with overall unclear risk of bias exists evaluating clinical and cost-effectiveness of NMP across all professions and clinical settings. GRADE assessment revealed moderate quality evidence. Evidence suggests that NMP is safe and can provide beneficial clinical outcomes. Benefits to the health economy remain unclear, with the cost-effectiveness of NMP assessed by a single pilot RCT of low risk of bias. Adequately powered low risk of bias RCTs evaluating clinical and cost effectiveness are required to evaluate NMP across clinical specialities, professions and settings. Registration PROSPERO (CRD42015017212). PMID:29509763

  6. Economics of Team-based Care in Controlling Blood Pressure: A Community Guide Systematic Review

    PubMed Central

    Jacob, Verughese; Chattopadhyay, Sajal K.; Thota, Anilkrishna B.; Proia, Krista K.; Njie, Gibril; Hopkins, David P.; Finnie, Ramona K.C.; Pronk, Nicolaas P.; Kottke, Thomas E.

    2015-01-01

    Context High blood pressure is an important risk factor for cardiovascular disease (CVD) and stroke, the leading cause of death in the U.S. and a substantial national burden through lost productivity and medical care. A recent Community Guide systematic review found strong evidence of effectiveness of team-based care in improving blood pressure control. The objective of the present review was to determine from the economic literature whether team-based care for blood pressure control is cost-beneficial and/or cost-effective. Evidence acquisition Electronic databases of papers published January 1980 – May 2012 were searched to find economic evaluations of team-based care interventions to improve blood pressure outcomes, yielding 31 studies for inclusion. Evidence synthesis In analyses conducted in 2012, intervention cost, healthcare cost averted, benefit-to-cost ratios, and cost-effectiveness were abstracted from the studies. The quality of estimates for intervention and healthcare cost from each study were assessed using three elements: intervention focus on blood pressure control; incremental estimates in the intervention group relative to a control group; and inclusion of major cost-driving elements in estimates. Intervention cost per unit reduction in systolic blood pressure was converted to lifetime intervention cost per quality-adjusted life-year (QALY) saved using algorithms from published trials. Conclusion Team-based care to improve blood pressure control is cost-effective based on evidence that 26 of 28 estimates of $/QALY gained from 10 studies were below a conservative threshold of $50,000. This finding is salient to recent health care reforms in the U.S. and coordinated patient-centered care through formation of Accountable Care Organizations (ACOs). PMID:26477804

  7. DPSK-3ASK transmission optimization by adapting modulation levels

    NASA Astrophysics Data System (ADS)

    Eiselt, Michael H.; Teipen, Brian T.

    2008-11-01

    For metro and regional 100-Gbps transmission, a transparent channel reach of 500-600 km is required and a 100-GHz channel grid is typically used. For these applications, a cost effective modulation format is introduced which can make use of electronic components designed for the already established 40-Gbps market, bypassing the requirements for novel electronic developments and therefore reducing the component cost. With this DPSK-3ASK modulation format, five information bits are transmitted in two consecutive symbols, leading to a symbol rate of 45 Gbaud, including overhead for framing and FEC. To minimize hardware requirements and to create a cost-effective solution, a single Mach-Zehnder modulator can be used to create the optical DPSK-3ASK signal after combining the phase and amplitude modulation signals into a 6-level modulator drive voltage. In this paper, it is demonstrated by numerical simulations that these voltage levels can be modified to adapt to varying signal distortions and thereby yield improved transmission performance. It is shown that by dynamically modifying the modulation levels based on the channel performance, dynamic signal impairments such as the non-linear effects from varying power levels, changes in chromatic dispersion, or varying PMD levels can be mitigated. Error-free performance (with FEC) can be obtained with 24 dB OSNR and 7ps DGD for a 112-Gbps (45-Gbaud) optical signal.

  8. Effects of space environment on composites: An analytical study of critical experimental parameters

    NASA Technical Reports Server (NTRS)

    Gupta, A.; Carroll, W. F.; Moacanin, J.

    1979-01-01

    A generalized methodology currently employed at JPL, was used to develop an analytical model for effects of high-energy electrons and interactions between electron and ultraviolet effects. Chemical kinetic concepts were applied in defining quantifiable parameters; the need for determining short-lived transient species and their concentration was demonstrated. The results demonstrates a systematic and cost-effective means of addressing the issues and show qualitative and quantitative, applicable relationships between space radiation and simulation parameters. An equally important result is identification of critical initial experiments necessary to further clarify the relationships. Topics discussed include facility and test design; rastered vs. diffuse continuous e-beam; valid acceleration level; simultaneous vs. sequential exposure to different types of radiation; and interruption of test continuity.

  9. A Low-Cost Electronic Solar Energy Control

    ERIC Educational Resources Information Center

    Blade, Richard A.; Small, Charles T.

    1978-01-01

    Describes the design of a low-cost electronic circuit to serve as a differential thermostat, to control the operation of a solar heating system. It uses inexpensive diodes for sensoring temperature, and a mechanical relay for a switch. (GA)

  10. [Development of a medical equipment support information system based on PDF portable document].

    PubMed

    Cheng, Jiangbo; Wang, Weidong

    2010-07-01

    According to the organizational structure and management system of the hospital medical engineering support, integrate medical engineering support workflow to ensure the medical engineering data effectively, accurately and comprehensively collected and kept in electronic archives. Analyse workflow of the medical, equipment support work and record all work processes by the portable electronic document. Using XML middleware technology and SQL Server database, complete process management, data calculation, submission, storage and other functions. The practical application shows that the medical equipment support information system optimizes the existing work process, standardized and digital, automatic and efficient orderly and controllable. The medical equipment support information system based on portable electronic document can effectively optimize and improve hospital medical engineering support work, improve performance, reduce costs, and provide full and accurate digital data

  11. The Role of Space Experiments in the Radiation Qualification of Electronic and Photonic Devices and Systems

    NASA Technical Reports Server (NTRS)

    Buchner, S.; LaBel, K.; Barth, J.; Campbell, A.

    2005-01-01

    Space experiments are occasionally launched to study the effects of radiation on electronic and photonic devices. This begs the following questions: Are space experiments necessary? Do the costs justify the benefits? How does one judge success of space experiment? What have we learned from past space experiments? How does one design a space experiment? This viewgraph presentation provides information on the usefulness of space and ground tests for simulating radiation damage to spacecraft components.

  12. Mechanically detected terahertz electron spin resonance using SOI-based thin piezoresistive microcantilevers

    NASA Astrophysics Data System (ADS)

    Ohmichi, Eiji; Miki, Toshihiro; Horie, Hidekazu; Okamoto, Tsubasa; Takahashi, Hideyuki; Higashi, Yoshinori; Itoh, Shoichi; Ohta, Hitoshi

    2018-02-01

    We developed piezoresistive microcantilevers for mechanically detected electron spin resonance (ESR) in the millimeter-wave region. In this article, fabrication process and device characterization of our self-sensing microcantilevers are presented. High-frequency ESR measurements of a microcrystal of paramagnetic sample is also demonstrated at multiple frequencies up to 160 GHz at liquid helium temperature. Our fabrication is based on relatively simplified processes with silicon-on-insulator (SOI) wafers and spin-on diffusion doping, thus enabling cost-effective and time-saving cantilever fabrication.

  13. Silk-molded flexible, ultrasensitive, and highly stable electronic skin for monitoring human physiological signals.

    PubMed

    Wang, Xuewen; Gu, Yang; Xiong, Zuoping; Cui, Zheng; Zhang, Ting

    2014-03-05

    Flexible and transparent E-skin devices are achieved by combining silk-molded micro-patterned polydimethylsiloxane (PDMS) with single-walled carbon nanotube (SWNT) ultrathin films. The E-skin sensing device demonstrates superior sensitivity, a very low detectable pressure limit, a fast response time, and a high stability for the detection of superslight pressures, which may broaden their potential use as cost-effective wearable electronics for healthcare applications. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Cost-effectiveness analysis of pharmacogenetic-guided warfarin dosing in Thailand.

    PubMed

    Chong, Huey Yi; Saokaew, Surasak; Dumrongprat, Kuntika; Permsuwan, Unchalee; Wu, David Bin-Chia; Sritara, Piyamitr; Chaiyakunapruk, Nathorn

    2014-12-01

    Pharmacogenetic (PGx) test is a useful tool for guiding physician on an initiation of an optimal warfarin dose. To implement of such strategy, the evidence on the economic value is needed. This study aimed to determine the cost-effectiveness of PGx-guided warfarin dosing compared with usual care (UC). A decision analytic model was used to compare projected lifetime costs and quality-adjusted life years (QALYs) accrued to warfarin users through PGx or UC for a hypothetical cohort of 1,000 patients. The model was populated with relevant information from systematic review, and electronic hospital-database. Incremental cost-effectiveness ratios (ICERs) were calculated based on healthcare system and societal perspectives. All costs were presented at year 2013. A series of sensitivity analyses were performed to determine the robustness of the findings. From healthcare system perspective, PGx increases QALY by 0.002 and cost by 2,959 THB (99 USD) compared with UC. Thus, the ICER is 1,477,042 THB (49,234 USD) per QALY gained. From societal perspective, PGx results in 0.002 QALY gained, and increases costs by 2,953 THB (98 USD) compared with UC (ICER 1,473,852 THB [49,128 USD] per QALY gained). Results are sensitive to the risk ratio (RR) of major bleeding in VKORC1 variant, the efficacy of PGx-guided dosing, and the cost of PGx test. Our finding suggests that PGx-guided warfarin dosing is unlikely to be a cost-effective intervention in Thailand. This evidence assists policy makers and clinicians in efficiently allocating scarce resources. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Cost-Effectiveness of Apixaban versus Warfarin in Chinese Patients with Non-Valvular Atrial Fibrillation: A Real-Life and Modelling Analyses

    PubMed Central

    Li, Xue; Tse, Vicki C.; Lau, Wallis C. Y.; Cheung, Bernard M. Y.; Lip, Gregory Y. H.; Wong, Ian C. K.; Chan, Esther W.

    2016-01-01

    Objectives Many of the cost-effectiveness analyses of apixaban against warfarin focused on Western populations but Asian evidence remains less clear. The present study aims to evaluate the cost-effectiveness of apixaban against warfarin in Chinese patients with non-valvular atrial fibrillation (NVAF) from a public institutional perspective in Hong Kong. Methods We used a Markov model incorporating 12 health state transitions, and simulated the disease progression of NVAF in 1,000 hypothetical patients treated with apixaban/warfarin. Risks of clinical events were based on the ARISTOTLE trial and were adjusted with local International Normalized Ratio control, defined as the time in therapeutic range. Real-life input for the model, including patients’ demographics and clinical profiles, post-event treatment patterns, and healthcare costs, were determined by a retrospective cohort of 40,569 incident patients retrieved from a Hong Kong-wide electronic medical database. Main outcome measurements included numbers of thromboembolic and bleeding events, life years, quality-adjusted life years (QALYs) and direct healthcare cost. When comparing apixaban and warfarin, treatment with incremental cost-effectiveness ratio (ICER) less than one local GDP per capita (USD 33,534 in 2014) was defined to be cost-effective. Results In the lifetime simulation, fewer numbers of events were estimated for the apixaban group, resulting in reduced event-related direct medical costs. The estimated ICER of apixaban was USD 7,057 per QALY at base-case analysis and ranged from USD 1,061 to 14,867 per QALY under the 116 tested scenarios in deterministic sensitivity analysis. While in probabilistic sensitivity analysis, the probability of apixaban being the cost-effective alternative to warfarin was 96% and 98% at a willingness to pay threshold of USD 33,534 and 100,602 per QALY, respectively. Conclusions Apixaban is likely to be a cost-effective alternative to warfarin for stroke prophylaxis in Chinese patients with NVAF in Hong Kong. PMID:27362421

  16. Cost-Effectiveness of Apixaban versus Warfarin in Chinese Patients with Non-Valvular Atrial Fibrillation: A Real-Life and Modelling Analyses.

    PubMed

    Li, Xue; Tse, Vicki C; Lau, Wallis C Y; Cheung, Bernard M Y; Lip, Gregory Y H; Wong, Ian C K; Chan, Esther W

    2016-01-01

    Many of the cost-effectiveness analyses of apixaban against warfarin focused on Western populations but Asian evidence remains less clear. The present study aims to evaluate the cost-effectiveness of apixaban against warfarin in Chinese patients with non-valvular atrial fibrillation (NVAF) from a public institutional perspective in Hong Kong. We used a Markov model incorporating 12 health state transitions, and simulated the disease progression of NVAF in 1,000 hypothetical patients treated with apixaban/warfarin. Risks of clinical events were based on the ARISTOTLE trial and were adjusted with local International Normalized Ratio control, defined as the time in therapeutic range. Real-life input for the model, including patients' demographics and clinical profiles, post-event treatment patterns, and healthcare costs, were determined by a retrospective cohort of 40,569 incident patients retrieved from a Hong Kong-wide electronic medical database. Main outcome measurements included numbers of thromboembolic and bleeding events, life years, quality-adjusted life years (QALYs) and direct healthcare cost. When comparing apixaban and warfarin, treatment with incremental cost-effectiveness ratio (ICER) less than one local GDP per capita (USD 33,534 in 2014) was defined to be cost-effective. In the lifetime simulation, fewer numbers of events were estimated for the apixaban group, resulting in reduced event-related direct medical costs. The estimated ICER of apixaban was USD 7,057 per QALY at base-case analysis and ranged from USD 1,061 to 14,867 per QALY under the 116 tested scenarios in deterministic sensitivity analysis. While in probabilistic sensitivity analysis, the probability of apixaban being the cost-effective alternative to warfarin was 96% and 98% at a willingness to pay threshold of USD 33,534 and 100,602 per QALY, respectively. Apixaban is likely to be a cost-effective alternative to warfarin for stroke prophylaxis in Chinese patients with NVAF in Hong Kong.

  17. Controlled synthesis of magnetic iron oxides@SnO2 quasi-hollow core-shell heterostructures: formation mechanism, and enhanced photocatalytic activity

    NASA Astrophysics Data System (ADS)

    Wu, Wei; Zhang, Shaofeng; Ren, Feng; Xiao, Xiangheng; Zhou, Juan; Jiang, Changzhong

    2011-11-01

    Iron oxide/SnO2 magnetic semiconductor core-shell heterostructures with high purity were synthesized by a low-cost, surfactant-free and environmentally friendly hydrothermal strategy via a seed-mediated method. The morphology and structure of the hybrid nanostructures were characterized by means of high-resolution transmission electron microscopy and X-ray diffraction. The morphology evolution investigations reveal that the Kirkendall effect directs the diffusion and causes the formation of iron oxide/SnO2 quasi-hollow particles. Significantly, the as-obtained iron oxides/SnO2 core-shell heterostructures exhibited enhanced visible light or UV photocatalytic abilities, remarkably superior to as-used α-Fe2O3 seeds and commercial SnO2 products, mainly owing to the effective electron hole separation at the iron oxides/SnO2 interfaces.Iron oxide/SnO2 magnetic semiconductor core-shell heterostructures with high purity were synthesized by a low-cost, surfactant-free and environmentally friendly hydrothermal strategy via a seed-mediated method. The morphology and structure of the hybrid nanostructures were characterized by means of high-resolution transmission electron microscopy and X-ray diffraction. The morphology evolution investigations reveal that the Kirkendall effect directs the diffusion and causes the formation of iron oxide/SnO2 quasi-hollow particles. Significantly, the as-obtained iron oxides/SnO2 core-shell heterostructures exhibited enhanced visible light or UV photocatalytic abilities, remarkably superior to as-used α-Fe2O3 seeds and commercial SnO2 products, mainly owing to the effective electron hole separation at the iron oxides/SnO2 interfaces. Electronic supplementary information (ESI) available: TEM and HRTEM images of hematite seeds and iron oxide/SnO2 (12 h and 36 h). See DOI: 10.1039/c1nr10728c

  18. Interventions to Improve Sexually Transmitted Disease Screening in Clinic-Based Settings.

    PubMed

    Taylor, Melanie M; Frasure-Williams, Jessica; Burnett, Phyllis; Park, Ina U

    2016-02-01

    The asymptomatic nature and suboptimal screening rates of sexually transmitted diseases (STD) call for implementation of successful interventions to improve screening in community-based clinic settings with attention to cost and resources. We used MEDLINE to systematically review comparative analyses of interventions to improve STD (chlamydia, gonorrhea, or syphilis) screening or rescreening in clinic-based settings that were published between January 2000 and January 2014. Absolute differences in the percent of the target population screened between comparison groups or relative percent increase in the number of tests or patients tested were used to score the interventions as highly effective (>20% increase) or moderately effective (5%-19% increase) in improving screening. Published cost of the interventions was described where available and, when not available, was estimated. Of the 4566 citations reviewed, 38 articles describing 42 interventions met the inclusion criteria. Of the 42 interventions, 16 (38.1%) were categorized as highly effective and 14 (33.3%) as moderately effective. Effective low-cost interventions (<$1000) included the strategic placement of specimen collection materials or automatic collection of STD specimens as part of a routine visit (7 highly effective and 1 moderately effective) and the use of electronic health records (EHRs; 3 highly effective and 4 moderately effective). Patient reminders for screening or rescreening (via text, telephone, and postcards) were highly effective (3) or moderately effective (2) and low or moderate cost (<$1001-10,000). Interventions with dedicated clinic staff to improve STD screening were highly effective (2) or moderately effective in improving STD screening (1) but high-cost ($10,001-$100,000). Successful interventions include changing clinic flow to routinely collect specimens for testing, using EHR screening reminders, and reminding patients to get screened or rescreened. These strategies can be tailored to different clinic settings to improve screening at a low cost.

  19. Cost-effectiveness of antibiotics for COPD management: observational analysis using CPRD data.

    PubMed

    Ronaldson, Sarah J; Raghunath, Anan; Torgerson, David J; Van Staa, Tjeerd

    2017-04-01

    It is often difficult to determine the cause of chronic obstructive pulmonary disease (COPD) exacerbations, and antibiotics are frequently prescribed. This study conducted an observational cost-effectiveness analysis of prescribing antibiotics for exacerbations of COPD based on routinely collected data from patient electronic health records. A cohort of 45 375 patients aged 40 years or more who attended their general practice for a COPD exacerbation during 2000-2013 was identified from the Clinical Practice Research Datalink. Two groups were formed ("immediate antibiotics" or "no antibiotics") based on whether antibiotics were prescribed during the index general practice (GP) consultation, with data analysed according to subsequent healthcare resource use. A cost-effectiveness analysis was undertaken from the perspective of the UK National Health Service, using a time horizon of 4 weeks in the base case. The use of antibiotics for COPD exacerbations resulted in cost savings and an improvement in all outcomes analysed; i.e. GP visits, hospitalisations, community respiratory team referrals, all referrals, infections and subsequent antibiotics prescriptions were lower for the antibiotics group. Hence, the use of antibiotics was dominant over no antibiotics. The economic analysis suggests that use of antibiotics for COPD exacerbations is a cost-effective alternative to not prescribing antibiotics for patients who present to their GP, and remains cost-effective when longer time horizons of 3 months and 12 months are considered. It would be useful for a definitive trial to be undertaken in this area to determine the cost-effectiveness of antibiotics for COPD exacerbations.

  20. Cost-effectiveness of antibiotics for COPD management: observational analysis using CPRD data

    PubMed Central

    Raghunath, Anan; Torgerson, David J.; Van Staa, Tjeerd

    2017-01-01

    It is often difficult to determine the cause of chronic obstructive pulmonary disease (COPD) exacerbations, and antibiotics are frequently prescribed. This study conducted an observational cost-effectiveness analysis of prescribing antibiotics for exacerbations of COPD based on routinely collected data from patient electronic health records. A cohort of 45 375 patients aged 40 years or more who attended their general practice for a COPD exacerbation during 2000–2013 was identified from the Clinical Practice Research Datalink. Two groups were formed (“immediate antibiotics” or “no antibiotics”) based on whether antibiotics were prescribed during the index general practice (GP) consultation, with data analysed according to subsequent healthcare resource use. A cost-effectiveness analysis was undertaken from the perspective of the UK National Health Service, using a time horizon of 4 weeks in the base case. The use of antibiotics for COPD exacerbations resulted in cost savings and an improvement in all outcomes analysed; i.e. GP visits, hospitalisations, community respiratory team referrals, all referrals, infections and subsequent antibiotics prescriptions were lower for the antibiotics group. Hence, the use of antibiotics was dominant over no antibiotics. The economic analysis suggests that use of antibiotics for COPD exacerbations is a cost-effective alternative to not prescribing antibiotics for patients who present to their GP, and remains cost-effective when longer time horizons of 3 months and 12 months are considered. It would be useful for a definitive trial to be undertaken in this area to determine the cost-effectiveness of antibiotics for COPD exacerbations. PMID:28656132

  1. A literature review to evaluate the economic value of ranolazine for the symptomatic treatment of chronic angina pectoris.

    PubMed

    Vellopoulou, Katerina; Kourlaba, Georgia; Maniadakis, Nikos; Vardas, Panagiotis

    2016-05-15

    To conduct a systematic review of the evidence regarding the economic value of ranolazine relative to standard-of-care (SOC) for the treatment of symptomatic chronic stable angina (CSA). Electronic databases were searched using relevant keywords. The identified studies were independently reviewed by two investigators against pre-determined inclusion and exclusion criteria. Their data were extracted using a relevant form and consequently were synthesized. Studies were also evaluated using the Quality of Health Economic Studies scale. The main outcomes considered were the cost and effectiveness for each comparator and the incremental cost per quality-adjusted-life year (QALY) gained. Six studies were included in the review. Five of these assessed the cost-utility of ranolazine added to SOC, compared to SOC alone, using decision trees or Markov models whereas one was a retrospective cost evaluation study. The analysis was conducted from a payer perspective in five studies and from a societal perspective in one study with the time horizon varying between six months and a year. The incremental cost-effectiveness ratio (ICER), ranged from €4000 to €15,000 per QALY gained. Ranolazine appears to be dominant or cost-effective, mainly due to its ability to decrease angina-related hospitalizations and also due to a marginal improvement in quality of life. The acquisition cost of ranolazine was the variable with the greatest impact upon the ICER. The existing evidence, although limited, indicates that ranolazine may be a dominant or cost-effective therapy option, for the treatment of patients with symptomatic CSA. Further research is required to evaluate the cost-effectiveness of ranolazine. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Numerical Study of Current Driven Instabilities and Anomalous Electron Transport in Hall-effect Thrusters

    NASA Astrophysics Data System (ADS)

    Tran, Jonathan

    Plasma turbulence and the resulting anomalous electron transport due to azimuthal current driven instabilities in Hall-effect thrusters is a promising candidate for developing predictive models for the observed anomalous transport. A theory for anomalous electron transport and current driven instabilities has been recently studied by [Lafluer et al., 2016a]. Due to the extreme cost of fully resolving the Debye length and plasma frequency, hybrid plasma simulations utilizing kinetic ions and quasi-steady state fluid electrons have long been the principle workhorse methodology for Hall-effect thruster modeling. Using a reduced dimension particle in cell simulation implemented in the Thermophysics Universal Research Framework developed by the Air Force Research Lab, we show collective electron-wave scattering due to large amplitude azimuthal fluctuations of the electric field and the plasma density. These high-frequency and short wavelength fluctuations can lead to an effective cross-field mobility many orders of magnitude larger than what is expected from classical electron-neutral momentum collisions in the low neutral density regime. We further adapt the previous study by [Lampe et al., 1971] and [Stringer, 1964] for related current driven instabilities to electric propulsion relevant mass ratios and conditions. Finally, we conduct a preliminary study of resolving this instability with a modified hybrid simulation with the hope of integration with established hybrid Hall-effect thruster simulations.

  3. Cost of Behavioral Interventions Utilizing Electronic Drug Monitoring for Antiretroviral Therapy Adherence

    PubMed Central

    Rasu, Rafia S.; Malewski, David F.; Banderas, Julie W.; Thomson, Domonique Malomo; Goggin, Kathy

    2013-01-01

    Objective To provide data on the actual costs associated with behavioral ART adherence interventions and electronic drug monitoring used in a clinical trial to inform their implementation in future studies and real-world practice. Methods Direct and time costs were calculated from a multi-site three-arm randomized controlled ART adherence trial. HIV positive participants (n = 204) were randomized to standard care (SC), enhanced counseling (EC), or EC and modified directly observed therapy (mDOT) interventions. Electronic drug monitoring (EDM) was used. Costs were calculated for various components of the 24-week adherence intervention. This economic evaluation was conducted from the perspective of an agency that may wish to implement these strategies. Sensitivity analyses were conducted to examine costs and savings associated with different scenarios. Results Total direct costs were $126,068 ($618/patient). Initial time costs were $53,590 ($262/patient). Base cost of labor was $0.36/minute. EC costs for 134 patients were $18,427 ($137/patient) and mDOT for 64 patients cost $18,638 ($291/patient). Total per patient costs were: SC=$880, EC=$1,018, EC/mDOT=$1,309. Removing driving costs evidenced the most variable impact on savings between the three study arms. The tornado diagram (sensitivity analysis) showed a graphical representation of how each sensitivity assumption reduced costs compared to each other and the resulting comparative costs for each group. Conclusion This novel economic analysis provides valuable cost information to guide treatment implementation and research design decisions. PMID:23337364

  4. Label-free detection of DNA hybridization using carbon nanotube network field-effect transistors

    NASA Astrophysics Data System (ADS)

    Star, Alexander; Tu, Eugene; Niemann, Joseph; Gabriel, Jean-Christophe P.; Joiner, C. Steve; Valcke, Christian

    2006-01-01

    We report carbon nanotube network field-effect transistors (NTNFETs) that function as selective detectors of DNA immobilization and hybridization. NTNFETs with immobilized synthetic oligonucleotides have been shown to specifically recognize target DNA sequences, including H63D single-nucleotide polymorphism (SNP) discrimination in the HFE gene, responsible for hereditary hemochromatosis. The electronic responses of NTNFETs upon single-stranded DNA immobilization and subsequent DNA hybridization events were confirmed by using fluorescence-labeled oligonucleotides and then were further explored for label-free DNA detection at picomolar to micromolar concentrations. We have also observed a strong effect of DNA counterions on the electronic response, thus suggesting a charge-based mechanism of DNA detection using NTNFET devices. Implementation of label-free electronic detection assays using NTNFETs constitutes an important step toward low-cost, low-complexity, highly sensitive and accurate molecular diagnostics. hemochromatosis | SNP | biosensor

  5. Cost-effectiveness of manual therapy for the management of musculoskeletal conditions: a systematic review and narrative synthesis of evidence from randomized controlled trials.

    PubMed

    Tsertsvadze, Alexander; Clar, Christine; Court, Rachel; Clarke, Aileen; Mistry, Hema; Sutcliffe, Paul

    2014-01-01

    The purpose of this study was to systematically review trial-based economic evaluations of manual therapy relative to other alternative interventions used for the management of musculoskeletal conditions. A comprehensive literature search was undertaken in major medical, health-related, science and health economic electronic databases. Twenty-five publications were included (11 trial-based economic evaluations). The studies compared cost-effectiveness and/or cost-utility of manual therapy interventions to other treatment alternatives in reducing pain (spinal, shoulder, ankle). Manual therapy techniques (e.g., osteopathic spinal manipulation, physiotherapy manipulation and mobilization techniques, and chiropractic manipulation with or without other treatments) were more cost-effective than usual general practitioner (GP) care alone or with exercise, spinal stabilization, GP advice, advice to remain active, or brief pain management for improving low back and shoulder pain/disability. Chiropractic manipulation was found to be less costly and more effective than alternative treatment compared with either physiotherapy or GP care in improving neck pain. Preliminary evidence from this review shows some economic advantage of manual therapy relative to other interventions used for the management of musculoskeletal conditions, indicating that some manual therapy techniques may be more cost-effective than usual GP care, spinal stabilization, GP advice, advice to remain active, or brief pain management for improving low back and shoulder pain/disability. However, at present, there is a paucity of evidence on the cost-effectiveness and/or cost-utility evaluations for manual therapy interventions. Further improvements in the methodological conduct and reporting quality of economic evaluations of manual therapy are warranted in order to facilitate adequate evidence-based decisions among policy makers, health care practitioners, and patients. Copyright © 2014 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  6. Tape transfer printing of a liquid metal alloy for stretchable RF electronics.

    PubMed

    Jeong, Seung Hee; Hjort, Klas; Wu, Zhigang

    2014-09-03

    In order to make conductors with large cross sections for low impedance radio frequency (RF) electronics, while still retaining high stretchability, liquid-alloy-based microfluidic stretchable electronics offers stretchable electronic systems the unique opportunity to combine various sensors on our bodies or organs with high-quality wireless communication with the external world (devices/systems), without sacrificing enhanced user comfort. This microfluidic approach, based on printed circuit board technology, allows large area processing of large cross section conductors and robust contacts, which can handle a lot of stretching between the embedded rigid active components and the surrounding system. Although it provides such benefits, further development is needed to realize its potential as a high throughput, cost-effective process technology. In this paper, tape transfer printing is proposed to supply a rapid prototyping batch process at low cost, albeit at a low resolution of 150 μm. In particular, isolated patterns can be obtained in a simple one-step process. Finally, a stretchable radio frequency identification (RFID) tag is demonstrated. The measured results show the robustness of the hybrid integrated system when the tag is stretched at 50% for 3000 cycles.

  7. Future Libraries: Dreams, Madness, & Reality.

    ERIC Educational Resources Information Center

    Crawford, Walt; Gorman, Michael

    Policymakers and library administrators are being drawn to the idea of the "virtual library" and the "library without walls," the webs of electronic resources that supposedly will displace books, physical libraries, and most library staff, and are believing the virtual library to be imminent, adequate, and cost-effective. This…

  8. Libraries, Self-Censorship, and Information Technologies.

    ERIC Educational Resources Information Center

    Buschman, John

    1994-01-01

    Explores the theme of self-censorship in libraries in relation to new technologies. Highlights include the results of investing in high-cost electronic resources at the expense of traditional, lower-status formats; the effect of information technologies on literacy and historical records; and market censorship, including centralization and…

  9. ``Low-cost Electronic nose evaluated on Thai-herb of Northern-Thailand samples using multivariate analysis methods''

    NASA Astrophysics Data System (ADS)

    na ayudhaya, Paisarn Daungjak; Klinbumrung, Arrak; Jaroensutasinee, Krisanadej; Pratontep, Sirapat; Kerdcharoen, Teerakiat

    2009-05-01

    In case of species of natural and aromatic plant originated from the northern Thailand, sensory characteristics, especially odours, have unique identifiers of herbs. The instruments sensory analysis have performed by several of differential of sensing, so call `electronic nose', to be a significantly and rapidly for chemometrics. The signal responses of the low cost electronic nose were evaluated by principal component analysis (PCA). The aims of this paper evaluated various of Thai-herbs grown in Northern of Thailand as data preprocessing tools of the Low-cost electronic nose (enNU-PYO1). The essential oil groups of Thai herbs such as Garlic, Lemongrass, Shallot (potato onion), Onion, Zanthoxylum limonella (Dennst.) Alston (Thai name is Makaen), and Kaffir lime leaf were compared volatilized from selected fresh herbs. Principal component analysis of the original sensor responses did clearly distinguish either all samples. In all cases more than 97% for cross-validated group were classified correctly. The results demonstrated that it was possible to develop in a model to construct a low-cost electronic nose to provide measurement of odoriferous herbs.

  10. Systematic review of economic evaluations of preparedness strategies and interventions against influenza pandemics.

    PubMed

    Pérez Velasco, Román; Praditsitthikorn, Naiyana; Wichmann, Kamonthip; Mohara, Adun; Kotirum, Surachai; Tantivess, Sripen; Vallenas, Constanza; Harmanci, Hande; Teerawattananon, Yot

    2012-01-01

    Although public health guidelines have implications for resource allocation, these issues were not explicitly considered in previous WHO pandemic preparedness and response guidance. In order to ensure a thorough and informed revision of this guidance following the H1N1 2009 pandemic, a systematic review of published and unpublished economic evaluations of preparedness strategies and interventions against influenza pandemics was conducted. The search was performed in September 2011 using 10 electronic databases, 2 internet search engines, reference list screening, cited reference searching, and direct communication with relevant authors. Full and partial economic evaluations considering both costs and outcomes were included. Conversely, reviews, editorials, and studies on economic impact or complications were excluded. Studies were selected by 2 independent reviewers. 44 studies were included. Although most complied with the cost effectiveness guidelines, the quality of evidence was limited. However, the data sources used were of higher quality in economic evaluations conducted after the 2009 H1N1 pandemic. Vaccination and drug regimens were varied. Pharmaceutical plus non-pharmaceutical interventions are relatively cost effective in comparison to vaccines and/or antivirals alone. Pharmaceutical interventions vary from cost saving to high cost effectiveness ratios. According to ceiling thresholds (Gross National Income per capita), the reduction of non-essential contacts and the use of pharmaceutical prophylaxis plus the closure of schools are amongst the cost effective strategies for all countries. However, quarantine for household contacts is not cost effective even for low and middle income countries. The available evidence is generally inconclusive regarding the cost effectiveness of preparedness strategies and interventions against influenza pandemics. Studies on their effectiveness and cost effectiveness should be readily implemented in forthcoming events that also involve the developing world. Guidelines for assessing the impact of disease and interventions should be drawn up to facilitate these studies.

  11. Systematic Review of Economic Evaluations of Preparedness Strategies and Interventions against Influenza Pandemics

    PubMed Central

    Pérez Velasco, Román; Praditsitthikorn, Naiyana; Wichmann, Kamonthip; Mohara, Adun; Kotirum, Surachai; Tantivess, Sripen; Vallenas, Constanza; Harmanci, Hande; Teerawattananon, Yot

    2012-01-01

    Background Although public health guidelines have implications for resource allocation, these issues were not explicitly considered in previous WHO pandemic preparedness and response guidance. In order to ensure a thorough and informed revision of this guidance following the H1N1 2009 pandemic, a systematic review of published and unpublished economic evaluations of preparedness strategies and interventions against influenza pandemics was conducted. Methods The search was performed in September 2011 using 10 electronic databases, 2 internet search engines, reference list screening, cited reference searching, and direct communication with relevant authors. Full and partial economic evaluations considering both costs and outcomes were included. Conversely, reviews, editorials, and studies on economic impact or complications were excluded. Studies were selected by 2 independent reviewers. Results 44 studies were included. Although most complied with the cost effectiveness guidelines, the quality of evidence was limited. However, the data sources used were of higher quality in economic evaluations conducted after the 2009 H1N1 pandemic. Vaccination and drug regimens were varied. Pharmaceutical plus non-pharmaceutical interventions are relatively cost effective in comparison to vaccines and/or antivirals alone. Pharmaceutical interventions vary from cost saving to high cost effectiveness ratios. According to ceiling thresholds (Gross National Income per capita), the reduction of non-essential contacts and the use of pharmaceutical prophylaxis plus the closure of schools are amongst the cost effective strategies for all countries. However, quarantine for household contacts is not cost effective even for low and middle income countries. Conclusion The available evidence is generally inconclusive regarding the cost effectiveness of preparedness strategies and interventions against influenza pandemics. Studies on their effectiveness and cost effectiveness should be readily implemented in forthcoming events that also involve the developing world. Guidelines for assessing the impact of disease and interventions should be drawn up to facilitate these studies. PMID:22393352

  12. Generalisability in economic evaluation studies in healthcare: a review and case studies.

    PubMed

    Sculpher, M J; Pang, F S; Manca, A; Drummond, M F; Golder, S; Urdahl, H; Davies, L M; Eastwood, A

    2004-12-01

    To review, and to develop further, the methods used to assess and to increase the generalisability of economic evaluation studies. Electronic databases. Methodological studies relating to economic evaluation in healthcare were searched. This included electronic searches of a range of databases, including PREMEDLINE, MEDLINE, EMBASE and EconLit, and manual searches of key journals. The case studies of a decision analytic model involved highlighting specific features of previously published economic studies related to generalisability and location-related variability. The case-study involving the secondary analysis of cost-effectiveness analyses was based on the secondary analysis of three economic studies using data from randomised trials. The factor most frequently cited as generating variability in economic results between locations was the unit costs associated with particular resources. In the context of studies based on the analysis of patient-level data, regression analysis has been advocated as a means of looking at variability in economic results across locations. These methods have generally accepted that some components of resource use and outcomes are exchangeable across locations. Recent studies have also explored, in cost-effectiveness analysis, the use of tests of heterogeneity similar to those used in clinical evaluation in trials. The decision analytic model has been the main means by which cost-effectiveness has been adapted from trial to non-trial locations. Most models have focused on changes to the cost side of the analysis, but it is clear that the effectiveness side may also need to be adapted between locations. There have been weaknesses in some aspects of the reporting in applied cost-effectiveness studies. These may limit decision-makers' ability to judge the relevance of a study to their specific situations. The case study demonstrated the potential value of multilevel modelling (MLM). Where clustering exists by location (e.g. centre or country), MLM can facilitate correct estimates of the uncertainty in cost-effectiveness results, and also a means of estimating location-specific cost-effectiveness. The review of applied economic studies based on decision analytic models showed that few studies were explicit about their target decision-maker(s)/jurisdictions. The studies in the review generally made more effort to ensure that their cost inputs were specific to their target jurisdiction than their effectiveness parameters. Standard sensitivity analysis was the main way of dealing with uncertainty in the models, although few studies looked explicitly at variability between locations. The modelling case study illustrated how effectiveness and cost data can be made location-specific. In particular, on the effectiveness side, the example showed the separation of location-specific baseline events and pooled estimates of relative treatment effect, where the latter are assumed exchangeable across locations. A large number of factors are mentioned in the literature that might be expected to generate variation in the cost-effectiveness of healthcare interventions across locations. Several papers have demonstrated differences in the volume and cost of resource use between locations, but few studies have looked at variability in outcomes. In applied trial-based cost-effectiveness studies, few studies provide sufficient evidence for decision-makers to establish the relevance or to adjust the results of the study to their location of interest. Very few studies utilised statistical methods formally to assess the variability in results between locations. In applied economic studies based on decision models, most studies either stated their target decision-maker/jurisdiction or provided sufficient information from which this could be inferred. There was a greater tendency to ensure that cost inputs were specific to the target jurisdiction than clinical parameters. Methods to assess generalisability and variability in economic evaluation studies have been discussed extensively in the literature relating to both trial-based and modelling studies. Regression-based methods are likely to offer a systematic approach to quantifying variability in patient-level data. In particular, MLM has the potential to facilitate estimates of cost-effectiveness, which both reflect the variation in costs and outcomes between locations and also enable the consistency of cost-effectiveness estimates between locations to be assessed directly. Decision analytic models will retain an important role in adapting the results of cost-effectiveness studies between locations. Recommendations for further research include: the development of methods of evidence synthesis which model the exchangeability of data across locations and allow for the additional uncertainty in this process; assessment of alternative approaches to specifying multilevel models to the analysis of cost-effectiveness data alongside multilocation randomised trials; identification of a range of appropriate covariates relating to locations (e.g. hospitals) in multilevel models; and further assessment of the role of econometric methods (e.g. selection models) for cost-effectiveness analysis alongside observational datasets, and to increase the generalisability of randomised trials.

  13. The NASA Electronic Parts and Packaging (NEPP) Program: Overview and the New Tenets for Cost Conscious Mission Assurance on Electrical, Electronic, and Electromechanical (EEE) Parts

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2015-01-01

    The NEPP Program focuses on the reliability aspects of electronic devices (integrated circuits such as a processor in a computer). There are three principal aspects of this reliability: 1) Lifetime, inherent failure and design issues related to the EEE parts technology and packaging; 2) Effects of space radiation and the space environment on these technologies, and; 3) Creation and maintenance of the assurance support infrastructure required for mission success. The NEPP mission is to provide guidance to NASA for the selection and application of microelectronics technologies, to improve understanding of the risks related to the use of these technologies in the space environment, and to ensure that appropriate EEE parts research is performed to meet NASA mission assurance needs. NEPPs FY15 goals are to represent the NASA voice to the greater aerospace EEE parts community including supporting anti-counterfeit and trust, provide relevant guidance to cost-effective missions, aid insertion of advanced (and commercial) technologies, resolve unexpected parts issues, ensure access to appropriate radiation test facilities, and collaborate as widely as possible with external entities. In accordance with the changing mission profiles throughout NASA, the NEPP Program has developed a balanced portfolio of efforts to provide agency-wide assurance for not only traditional spacecraft developments, but also those in-line with the new philosophies emerging worldwide. In this presentation, we shall present an overview of this program and considerations for EEE parts assurance as applied to cost conscious missions.

  14. Research on fault characteristics about switching component failures for distribution electronic power transformers

    NASA Astrophysics Data System (ADS)

    Sang, Z. X.; Huang, J. Q.; Yan, J.; Du, Z.; Xu, Q. S.; Lei, H.; Zhou, S. X.; Wang, S. C.

    2017-11-01

    The protection is an essential part for power device, especially for those in power grid, as the failure may cost great losses to the society. A study on the voltage and current abnormality in the power electronic devices in Distribution Electronic Power Transformer (D-EPT) during the failures on switching components is presented, as well as the operational principles for 10 kV rectifier, 10 kV/400 V DC-DC converter and 400 V inverter in D-EPT. Derived from the discussion on the effects of voltage and current distortion, the fault characteristics as well as a fault diagnosis method for D-EPT are introduced.

  15. Strategies and Opportunities to STOP Colon Cancer in Priority Populations: Design of a Cluster-Randomized Pragmatic Trial

    PubMed Central

    Coronado, Gloria D.; Vollmer, William M.; Petrik, Amanda; Taplin, Stephen H.; Burdick, Timothy E.; Meenan, Richard T.; Green, Beverly

    2014-01-01

    Background Colorectal cancer is the second-leading cause of cancer deaths in the United States. The Strategies and Opportunities to Stop Colorectal Cancer (STOP CRC) in Priority Populations study is a pragmatic trial and a collaboration between two research institutions and a network of more than 200 safety net clinics. The study will assess effectiveness of a systems-based intervention designed to improve rates of colorectal-cancer screening using fecal immunochemical testing (FIT) in federally qualified health centers in Oregon and Northern California. Material and Methods STOP CRC is a cluster-randomized comparative-effectiveness pragmatic trial enrolling 26 clinics. Clinics will be randomized to one of two arms. Clinics in the intervention arm (1) will use an automated, data-driven, electronic health record-embedded program to identify patients due for colorectal screening and mail FIT kits (with pictographic instructions) to them; (2) will conduct an improvement process (e.g. Plan-Do-Study-Act) to enhance the adoption, reach, and effectiveness of the program. Clinics in the control arm will provide opportunistic colorectal-cancer screening to patients at clinic visits. The primary outcomes are: proportion of age– and screening-eligible patients completing a FIT within 12 months; and cost, cost-effectiveness, and return on investment of the intervention. Conclusions This large-scale pragmatic trial will leverage electronic health record information and existing clinic staff to enroll a broad range of patients, including many with historically low colorectal-cancer screening rates. If successful, the program will provide a model for a cost-effective and scalable method to raise colorectal-cancer screening rates. PMID:24937017

  16. Accurate and Efficient Approximation to the Optimized Effective Potential for Exchange

    NASA Astrophysics Data System (ADS)

    Ryabinkin, Ilya G.; Kananenka, Alexei A.; Staroverov, Viktor N.

    2013-07-01

    We devise an efficient practical method for computing the Kohn-Sham exchange-correlation potential corresponding to a Hartree-Fock electron density. This potential is almost indistinguishable from the exact-exchange optimized effective potential (OEP) and, when used as an approximation to the OEP, is vastly better than all existing models. Using our method one can obtain unambiguous, nearly exact OEPs for any reasonable finite one-electron basis set at the same low cost as the Krieger-Li-Iafrate and Becke-Johnson potentials. For all practical purposes, this solves the long-standing problem of black-box construction of OEPs in exact-exchange calculations.

  17. Transparent and flexible heaters based on Al:ZnO degenerate semiconductor

    NASA Astrophysics Data System (ADS)

    Roul, Monee K.; Obasogie, Brandon; Kogo, Gilbert; Skuza, J. R.; Mundle, R. M.; Pradhan, A. K.

    2017-10-01

    We report on high performance transparent Al:ZnO (AZO) thin film heaters on flexible polymer (polyethylene terephthalate) and glass substrates which demonstrate low sheet resistivity. AZO thin films were grown by radio-frequency magnetron sputtering at low Ts (below 200 °C) on flexible, transparent polyethylene terephthalate substrates that show stable and reproducible results by applying low (<10 V) voltages. This study also examined identical AZO thin films on glass substrates that showed highly reproducible heating effects due to the Joule heating effect. The potential applications are foldable and wearable electronics, pain/injury therapy smart windows, automobile window defrosters, and low-cost power electronics.

  18. A new electrode design for ambipolar injection in organic semiconductors.

    PubMed

    Kanagasekaran, Thangavel; Shimotani, Hidekazu; Shimizu, Ryota; Hitosugi, Taro; Tanigaki, Katsumi

    2017-10-17

    Organic semiconductors have attracted much attention for low-cost, flexible and human-friendly optoelectronics. However, achieving high electron-injection efficiency is difficult from air-stable electrodes and cannot be equivalent to that of holes. Here, we present a novel concept of electrode composed of a bilayer of tetratetracontane (TTC) and polycrystalline organic semiconductors (pc-OSC) covered by a metal layer. Field-effect transistors of single-crystal organic semiconductors with the new electrodes of M/pc-OSC/TTC (M: Ca or Au) show both highly efficient electron and hole injection. Contact resistance for electron injection from Au/pc-OSC/TTC and hole injection from Ca/pc-OSC/TTC are comparable to those for electron injection from Ca and hole injection from Au, respectively. Furthermore, the highest field-effect mobilities of holes (22 cm 2  V -1  s -1 ) and electrons (5.0 cm 2  V -1  s -1 ) are observed in rubrene among field-effect transistors with electrodes so far proposed by employing Ca/pc-OSC/TTC and Au/pc-OSC/TTC electrodes for electron and hole injection, respectively.One of technological challenges building organic electronics is efficient injection of electrons at metal-semiconductor interfaces compared to that of holes. The authors show an air-stable electrode design with induced gap states, which support Fermi level pinning and thus ambipolar carrier injection.

  19. The Cost-Utility Analysis of PET-Scan in Diagnosis and Treatment of Non-Small Cell Lung Carcinoma in Iran.

    PubMed

    Akbari Sari, Ali; Ravaghi, Hamid; Mobinizadeh, Mohammadreza; Sarvari, Sima

    2013-06-01

    PET scan is a non-invasive, complex and expensive medical imaging technology that is normally used for the diagnosis and treatment of various diseases including lung cancer. The purpose of this study is to assess the cost effectiveness of this technology in the diagnosis and treatment of non- small cell lung carcinoma (NSCLC) in Iran. The main electronic databases including The Cochrane Library and Medline were searched to identify available evidence about the performance and effectiveness of technology. A standard decision tree model with seven strategies was used to perform the economic evaluation. Retrieved studies and expert opinion were used to estimate the cost of each treatment strategy in Iran. The costs were divided into three categories including capital costs (depreciation costs of buildings and equipment), staff costs and other expenses (including cost of consumables, running and maintenance costs). The costs were estimated in both IR-Rials and US-Dollars with an exchange rate of 10.000 IR Rials per one US Dollar according to the exchange rate in 2008. The total annual running cost of a PET scan was about 8850 to 13000 million Rials, (0.9 to 1.3 million US$). The average cost of performing a PET scan varied between 3 and 4.5 million Rials (300 to 450US$). The strategies 3 (mediastinoscopy alone) and 7 (mediastinoscopy after PET scan) were more cost-effective than other strategies, especially when the result of the CT-scan performed before PET scan was negative. The technical performance of PET scan is significantly higher than similar technologies for staging and treatment of NSCLC. In addition, it might slightly improve the treatment process and lead to a small level of increase in the quality adjusted life year (QALY) gained by these patients making it cost-effective for the treatment of NSCLC.

  20. Development and Validation of Various Phenotyping Algorithms for Diabetes Mellitus Using Data from Electronic Health Records.

    PubMed

    Esteban, Santiago; Rodríguez Tablado, Manuel; Peper, Francisco; Mahumud, Yamila S; Ricci, Ricardo I; Kopitowski, Karin; Terrasa, Sergio

    2017-01-01

    Precision medicine requires extremely large samples. Electronic health records (EHR) are thought to be a cost-effective source of data for that purpose. Phenotyping algorithms help reduce classification errors, making EHR a more reliable source of information for research. Four algorithm development strategies for classifying patients according to their diabetes status (diabetics; non-diabetics; inconclusive) were tested (one codes-only algorithm; one boolean algorithm, four statistical learning algorithms and six stacked generalization meta-learners). The best performing algorithms within each strategy were tested on the validation set. The stacked generalization algorithm yielded the highest Kappa coefficient value in the validation set (0.95 95% CI 0.91, 0.98). The implementation of these algorithms allows for the exploitation of data from thousands of patients accurately, greatly reducing the costs of constructing retrospective cohorts for research.

  1. Fully printable, strain-engineered electronic wrap for customizable soft electronics.

    PubMed

    Byun, Junghwan; Lee, Byeongmoon; Oh, Eunho; Kim, Hyunjong; Kim, Sangwoo; Lee, Seunghwan; Hong, Yongtaek

    2017-03-24

    Rapid growth of stretchable electronics stimulates broad uses in multidisciplinary fields as well as industrial applications. However, existing technologies are unsuitable for implementing versatile applications involving adaptable system design and functions in a cost/time-effective way because of vacuum-conditioned, lithographically-predefined processes. Here, we present a methodology for a fully printable, strain-engineered electronic wrap as a universal strategy which makes it more feasible to implement various stretchable electronic systems with customizable layouts and functions. The key aspects involve inkjet-printed rigid island (PRI)-based stretchable platform technology and corresponding printing-based automated electronic functionalization methodology, the combination of which provides fully printed, customized layouts of stretchable electronic systems with simplified process. Specifically, well-controlled contact line pinning effect of printed polymer solution enables the formation of PRIs with tunable thickness; and surface strain analysis on those PRIs leads to the optimized stability and device-to-island fill factor of strain-engineered electronic wraps. Moreover, core techniques of image-based automated pinpointing, surface-mountable device based electronic functionalizing, and one-step interconnection networking of PRIs enable customized circuit design and adaptable functionalities. To exhibit the universality of our approach, multiple types of practical applications ranging from self-computable digital logics to display and sensor system are demonstrated on skin in a customized form.

  2. Fully printable, strain-engineered electronic wrap for customizable soft electronics

    NASA Astrophysics Data System (ADS)

    Byun, Junghwan; Lee, Byeongmoon; Oh, Eunho; Kim, Hyunjong; Kim, Sangwoo; Lee, Seunghwan; Hong, Yongtaek

    2017-03-01

    Rapid growth of stretchable electronics stimulates broad uses in multidisciplinary fields as well as industrial applications. However, existing technologies are unsuitable for implementing versatile applications involving adaptable system design and functions in a cost/time-effective way because of vacuum-conditioned, lithographically-predefined processes. Here, we present a methodology for a fully printable, strain-engineered electronic wrap as a universal strategy which makes it more feasible to implement various stretchable electronic systems with customizable layouts and functions. The key aspects involve inkjet-printed rigid island (PRI)-based stretchable platform technology and corresponding printing-based automated electronic functionalization methodology, the combination of which provides fully printed, customized layouts of stretchable electronic systems with simplified process. Specifically, well-controlled contact line pinning effect of printed polymer solution enables the formation of PRIs with tunable thickness; and surface strain analysis on those PRIs leads to the optimized stability and device-to-island fill factor of strain-engineered electronic wraps. Moreover, core techniques of image-based automated pinpointing, surface-mountable device based electronic functionalizing, and one-step interconnection networking of PRIs enable customized circuit design and adaptable functionalities. To exhibit the universality of our approach, multiple types of practical applications ranging from self-computable digital logics to display and sensor system are demonstrated on skin in a customized form.

  3. Fully printable, strain-engineered electronic wrap for customizable soft electronics

    PubMed Central

    Byun, Junghwan; Lee, Byeongmoon; Oh, Eunho; Kim, Hyunjong; Kim, Sangwoo; Lee, Seunghwan; Hong, Yongtaek

    2017-01-01

    Rapid growth of stretchable electronics stimulates broad uses in multidisciplinary fields as well as industrial applications. However, existing technologies are unsuitable for implementing versatile applications involving adaptable system design and functions in a cost/time-effective way because of vacuum-conditioned, lithographically-predefined processes. Here, we present a methodology for a fully printable, strain-engineered electronic wrap as a universal strategy which makes it more feasible to implement various stretchable electronic systems with customizable layouts and functions. The key aspects involve inkjet-printed rigid island (PRI)-based stretchable platform technology and corresponding printing-based automated electronic functionalization methodology, the combination of which provides fully printed, customized layouts of stretchable electronic systems with simplified process. Specifically, well-controlled contact line pinning effect of printed polymer solution enables the formation of PRIs with tunable thickness; and surface strain analysis on those PRIs leads to the optimized stability and device-to-island fill factor of strain-engineered electronic wraps. Moreover, core techniques of image-based automated pinpointing, surface-mountable device based electronic functionalizing, and one-step interconnection networking of PRIs enable customized circuit design and adaptable functionalities. To exhibit the universality of our approach, multiple types of practical applications ranging from self-computable digital logics to display and sensor system are demonstrated on skin in a customized form. PMID:28338055

  4. Towards roll-to-roll fabrication of electronics, optics, and optoelectronics for smart and intelligent packaging

    NASA Astrophysics Data System (ADS)

    Kololuoma, Terho K.; Tuomikoski, Markus; Makela, Tapio; Heilmann, Jali; Haring, Tomi; Kallioinen, Jani; Hagberg, Juha; Kettunen, Ilkka; Kopola, Harri K.

    2004-06-01

    Embedding of optoelectrical, optical, and electrical functionalities into low-cost products like packages and printed matter can be used to increase their information content. These functionalities make also possible the realization of new type of entertaining, impressive or guiding effects on the product packages and printed matter. For these purposes, components like displays, photodetectors, light sources, solar cells, battery elements, diffractive optical elements, lightguides, electrical conductors, resistors, transistors, switching elements etc. and their integration to functional modules are required. Additionally, the price of the components for low-end products has to be in cent scale or preferably below that. Therefore, new, cost-effective, and volume scale capable manufacturing techniques are required. Recent developments of liquid-phase processable electrical and optical polymeric, inorganic, and hybrid materials - inks - have made it possible to fabricate functional electrical, optical and optoelectrical components by conventional roll-to-roll techniques such as gravure printing, embossing, digital printing, offset, and screen printing on flexible paper and plastic like substrates. In this paper, we show our current achievements in the field of roll-to-roll fabricated, optics, electronics and optoelectronics. With few examples, we also demonstrate the printing and hot-embossing capabilities of table scale printing machines and VTT Electronic's 'PICO' roll-to-roll pilot production facility.

  5. Smart home design for electronic devices monitoring based wireless gateway network using cisco packet tracer

    NASA Astrophysics Data System (ADS)

    Sihombing, Oloan; Zendrato, Niskarto; Laia, Yonata; Nababan, Marlince; Sitanggang, Delima; Purba, Windania; Batubara, Diarmansyah; Aisyah, Siti; Indra, Evta; Siregar, Saut

    2018-04-01

    In the era of technological development today, the technology has become the need for the life of today's society. One is needed to create a smart home in turning on and off electronic devices via smartphone. So far in turning off and turning the home electronic device is done by pressing the switch or remote button, so in control of electronic device control less effective. The home smart design is done by simulation concept by testing system, network configuration, and wireless home gateway computer network equipment required by a smart home network on cisco packet tracer using Internet Thing (IoT) control. In testing the IoT home network wireless network gateway system, multiple electronic devices can be controlled and monitored via smartphone based on predefined configuration conditions. With the Smart Ho me can potentially increase energy efficiency, decrease energy usage costs, control electronics and change the role of residents.

  6. Adhesion and the Lamination/Failure of Stretchable Organic and Composite Organic/Inorganic Electronic Structures

    NASA Astrophysics Data System (ADS)

    Yu, Deying

    Stretchable organic electronics have emerged as interesting technologies for several applications where stretchability is considered important. The easy and low-cost deposition procedures for the fabrication of stretchable organic solar cells and organic light emitting devices reduce the overall cost for the fabrication of these devices. However, the interfacial cracks and defects at the interfaces of the devices, during fabrication, are detrimental to the performance of stretchable organic electronic devices. Also, as the devices are deformed under service conditions, it is possible for cracks to grow. Furthermore, the multilayered structures of the devices can fail due to the delamination and buckling of the layered structures. There is, therefore, a need to study the failure mechanism in the layered structures that are relevant to stretchable organic electronic devices. Hence, in this study, a combined experimental, analytical and computational approach is used to study the effects of adhesion and deformation on the failure mechanisms in structures that are relevant to stretchable electronic devices. First, the failure mechanisms are studied in stretchable inorganic electronic structures. The wrinkles and buckles are formed by the unloading of pre-stretched PDMS/Au structure, after the evaporation of nano-scale Au layers. They are then characterized using atomic force microscopy and scanning electron microscopy. Analytical models are used to determine the critical stresses for wrinkling and buckling. The interfacial cracking and film buckling that can occur are also studied using finite element simulations. The implications of the results are then discussed for the potential applications of micro-wrinkles and micro-buckles in the stretchable electronic structures and biomedical devices. Subsequently, the adhesion between bi-material pairs that are relevant to organic light emitting devices, composite organic/inorganic light emitting devices, organic bulk heterojunction solar cells, and composite organic/inorganic solar cells on flexible substrates, is measured using force microscopy (AFM) techniques. The AFM measurements are incorporated into the Derjaguin-Muller-Toporov model to calculate the adhesion energies. The implications of the results are then discussed for the design of robust organic and composite organic/inorganic electronic devices. Finally, the lamination of organic solar cells and organic light emitting devices is studied using a combination of experimental, computational, and analytical approaches. First, the effects of applied lamination force (on contact between the laminated layers) are studied using experiments and models. The crack driving forces associated with the interfacial cracks that form at the interfaces between layers (at the bi-material interfaces) are estimated along with the critical interfacial crack driving forces associated with the separation of thin films, after layer transfer. The conditions for successful lamination are predicted using a combination of experiments and models. Guidelines are developed for the lamination of low-cost organic electronic structures.

  7. Alternative Nonvolatile Residue Analysis with Contaminant Identification Project

    NASA Technical Reports Server (NTRS)

    Loftin, Kathleen (Compiler); Summerfield, Burton (Compiler); Thompson, Karen (Compiler); Mullenix, Pamela (Compiler); Zeitlin, Nancy (Compiler)

    2015-01-01

    Cleanliness verification is required in numerous industries including spaceflight ground support, electronics, medical and aerospace. Currently at KSC requirement for cleanliness verification use solvents that environmentally unfriendly. This goal of this project is to produce an alternative cleanliness verification technique that is both environmentally friendly and more cost effective.

  8. Use of heat pipes in electronic hardware

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1977-01-01

    A modular, multiple output power converter was developed in order to reduce costs of space hardware in future missions. The converter is of reduced size and weight, and utilizes advanced heat removal techniques, in the form of heat pipes which remove internally generated heat more effectively than conventional methods.

  9. Integrating Social Media Technologies in Higher Education: Costs-Benefits Analysis

    ERIC Educational Resources Information Center

    Okoro, Ephraim

    2012-01-01

    Social networking and electronic channels of communication are effective tools in the process of teaching and learning and have increasingly improved the quality of students' learning outcomes in higher education in recent years. The process encourages students' active engagement, collaboration, and participation in class activities and group…

  10. Potential of Audiographic Computerized Telelearning for Distance Extension Education.

    ERIC Educational Resources Information Center

    Verma, Satish; And Others

    In the last 10 years, an approach to electronic distance education called audiographic computerized telelearning using standard telephone lines has come to the fore. Telelearning is a cost-effective system which optimizes existing computer facilities and creates a teaching-learning environment that is interactive, efficient, and adaptable to a…

  11. Electronic Training at the Corporate Level in Egypt: Applicability and Effectiveness

    ERIC Educational Resources Information Center

    Kamel, S.; Ibrahim, M.

    2003-01-01

    Declining revenue, staff downsizing and limited resources in corporations create serious organizational challenges. Training and human resources departments are often among the most adversely affected. Training managers are left with fewer resources with which to fulfil corporate training needs. Continuously having to justify costs and investments…

  12. A Self-Report Measure of Physical Activity

    ERIC Educational Resources Information Center

    Siegel, Donald

    2005-01-01

    There are multiple approaches to measuring physical activity. Among these are direct observation, electronic monitoring, direct and indirect calorimetry, and self-report instruments. Self-report instruments are the most practical and cost effective option for use with a large group. In a study by Motl, Dishman, Dowda, and Pate (2004), two groups…

  13. E-Learning: Emerging Uses, Empirical Results and Future Directions.

    ERIC Educational Resources Information Center

    Welsh, Elizabeth T.; Wanberg, Connie R.; Brown, Kenneth G.; Simmering, Marcia J.

    2003-01-01

    Literature review and interviews with 22 experts examined how and why electronic learning is being used by organizations. Growth in synchronous communication, blended solutions, and improved access were found. Review of research evidence suggested that most people can learn effectively with technology, technology can reduce training costs with…

  14. Increased mobility and on/off ratio in organic field-effect transistors using low-cost guanine-pentacene multilayers

    NASA Astrophysics Data System (ADS)

    Shi, Wei; Zheng, Yifan; Taylor, André D.; Yu, Junsheng; Katz, Howard E.

    2017-07-01

    Layer-by-layer deposited guanine and pentacene in organic field-effect transistors (OFETs) is introduced. Through adjusting the layer thickness ratio of guanine and pentacene, the tradeoff of two electronic parameters in OFETs, charge carrier mobility and current on/off ratio, was controlled. The charge mobility was enhanced by depositing pentacene over and between guanine layers and by increasing the proportion of pentacene in the layer-by-layer system, while the current on/off ratio was increased via the decreased off current induced by the guanine layers. The tunable device performance was mainly ascribed to the trap and dopant neutralizing properties of the guanine layers, which would decrease the density of free hydroxyl groups in the OFETs. Furthermore, the cost of the devices could be reduced remarkably via the adoption of low-cost guanine.

  15. Physical and mechanical metallurgy of high purity Nb accelerator cavities.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wright, N. T.; Bieler, T. R.; Pourgoghart , F.

    2010-01-01

    In the past decade, high Q values have been achieved in high purity Nb superconducting radio frequency (SRF) cavities. Fundamental understanding of the physical metallurgy of Nb that enables these achievements is beginning to reveal what challenges remain to establish reproducible and cost-effective production of high performance SRF cavities. Recent studies of dislocation substructure development and effects of recrystallization arising from welding and heat treatments and their correlations with cavity performance are considered. With better fundamental understanding of the effects of dislocation substructure evolution and recrystallization on electron and phonon conduction, as well as the interior and surface states, itmore » will be possible to design optimal processing paths for cost-effective performance using approaches such as hydroforming, which minimizes or eliminates welds in a cavity.« less

  16. Physical and mechanical metallurgy of high purity Nb for accelerator cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieler, T. R.; Wright, N. T.; Pourboghrat, F.

    2010-01-01

    In the past decade, high Q values have been achieved in high purity Nb superconducting radio frequency (SRF) cavities. Fundamental understanding of the physical metallurgy of Nb that enables these achievements is beginning to reveal what challenges remain to establish reproducible and cost-effective production of high performance SRF cavities. Recent studies of dislocation substructure development and effects of recrystallization arising from welding and heat treatments and their correlations with cavity performance are considered. With better fundamental understanding of the effects of dislocation substructure evolution and recrystallization on electron and phonon conduction, as well as the interior and surface states, itmore » will be possible to design optimal processing paths for cost-effective performance using approaches such as hydroforming, which minimizes or eliminates welds in a cavity.« less

  17. Compensating the electron beam energy spread by the natural transverse gradient of laser undulator in all-optical x-ray light sources.

    PubMed

    Zhang, Tong; Feng, Chao; Deng, Haixiao; Wang, Dong; Dai, Zhimin; Zhao, Zhentang

    2014-06-02

    All-optical ideas provide a potential to dramatically cut off the size and cost of x-ray light sources to the university-laboratory scale, with the combination of the laser-plasma accelerator and the laser undulator. However, the large longitudinal energy spread of the electron beam from laser-plasma accelerator may hinder the way to high brightness of these all-optical light sources. In this paper, the beam energy spread effect is proposed to be significantly compensated by the natural transverse gradient of a laser undulator when properly transverse-dispersing the electron beam. Theoretical analysis and numerical simulations on conventional laser-Compton scattering sources and high-gain all-optical x-ray free-electron lasers with the electron beams from laser-plasma accelerators are presented.

  18. Influence of Sun and Other Cosmic Factors on Environment of the Earth

    DTIC Science & Technology

    2010-01-07

    of the secondary cosmic rays (mostly muons , electrons, neutrons and gammas) can provide highly cost-effective information on the key characteristics...Coronal mass ejection (CME) from the Sun the impact on the Galactic Cosmic rays (GCR) will be observed. Particle detector is vital for measuring the...modulation effects the sun poses on the ambient population of the Galactic Cosmic Rays (GCR). The known agents of these modulation effects are Solar Flares

  19. The effects of patient cost sharing on inpatient utilization, cost, and outcome.

    PubMed

    Xu, Yuan; Li, Ning; Lu, Mingshan; Dixon, Elijah; Myers, Robert P; Jelley, Rachel J; Quan, Hude

    2017-01-01

    Health insurance and provider payment reforms all over the world beg a key empirical question: what are the potential impacts of patient cost-sharing on health care utilization, cost and outcomes? The unique health insurance system and rich electronic medical record (EMR) data in China provides us a unique opportunity to study this topic. Four years (2010 to 2014) of EMR data from one medical center in China were utilized, including 10,858 adult patients with liver diseases. We measured patient cost-sharing using actual reimbursement ratio (RR) which is allowed us to better capture financial incentive than using type of health insurance. A rigorous risk adjustment method was employed with both comorbidities and disease severity measures acting as risk adjustors. Associations between RR and health use, costs and outcome were analyzed by multivariate analyses. After risk adjustment, patients with more generous health insurance coverage (higher RR) were found to have longer hospital stay, higher total cost, higher medication cost, and higher ratio of medication to total cost, as well as higher number and likelihood that specific procedures were performed. Our study implied that patient cost-sharing affects health care services use and cost. This reflects how patients and physicians respond to financial incentives in the current healthcare system in China, and the responses could be a joint effect of both demand and supply side moral hazard. In order to contain cost and improve efficiency in the system, reforming provide payment and insurance scheme is urgently needed.

  20. Prediction and measurement results of radiation damage to CMOS devices on board spacecraft

    NASA Technical Reports Server (NTRS)

    Stassinopoulos, E. G.; Danchenko, V.; Cliff, R. A.; Sing, M.; Brucker, G. J.; Ohanian, R. S.

    1977-01-01

    Final results from the CMOS Radiation Effects Measurement (CREM) experiment flown on Explorer 55 are presented and discussed, based on about 15 months of observations and measurements. Conclusions are given relating to long-range annealing, effects of operating temperature on semiconductor performance in space, biased and unbiased P-MOS device degradation, unbiased n-channel device performance, changes in device transconductance, and the difference in ionization efficiency between Co-60 gamma rays and 1-Mev Van de Graaff electrons. The performance of devices in a heavily shielded electronic subsystem box within the spacecraft is evaluated and compared. Environment models and computational methods and their impact on device-degradation estimates are being reviewed to determine whether they permit cost-effective design of spacecraft.

  1. A systematic review of models used in cost-effectiveness analyses of preventing osteoporotic fractures.

    PubMed

    Si, L; Winzenberg, T M; Palmer, A J

    2014-01-01

    This review was aimed at the evolution of health economic models used in evaluations of clinical approaches aimed at preventing osteoporotic fractures. Models have improved, with medical continuance becoming increasingly recognized as a contributor to health and economic outcomes, as well as advancements in epidemiological data. Model-based health economic evaluation studies are increasingly used to investigate the cost-effectiveness of osteoporotic fracture preventions and treatments. The objective of this study was to carry out a systematic review of the evolution of health economic models used in the evaluation of osteoporotic fracture preventions. Electronic searches within MEDLINE and EMBASE were carried out using a predefined search strategy. Inclusion and exclusion criteria were used to select relevant studies. References listed of included studies were searched to identify any potential study that was not captured in our electronic search. Data on country, interventions, type of fracture prevention, evaluation perspective, type of model, time horizon, fracture sites, expressed costs, types of costs included, and effectiveness measurement were extracted. Seventy-four models were described in 104 publications, of which 69% were European. Earlier models focused mainly on hip, vertebral, and wrist fracture, but later models included multiple fracture sites (humerus, pelvis, tibia, and other fractures). Modeling techniques have evolved from simple decision trees, through deterministic Markov processes to individual patient simulation models accounting for uncertainty in multiple parameters. Treatment continuance has been increasingly taken into account in the models in the last decade. Models have evolved in their complexity and emphasis, with medical continuance becoming increasingly recognized as a contributor to health and economic outcomes. This evolution may be driven in part by the desire to capture all the important differentiating characteristics of medications under scrutiny, as well as the advancement in epidemiological data relevant to osteoporosis fractures.

  2. Effect of electronic prescribing with formulary decision support on medication use and cost.

    PubMed

    Fischer, Michael A; Vogeli, Christine; Stedman, Margaret; Ferris, Timothy; Brookhart, M Alan; Weissman, Joel S

    2008-12-08

    Electronic prescribing (e-prescribing) with formulary decision support (FDS) prompts prescribers to prescribe lower-cost medications and may help contain health care costs. In April 2004, 2 large Massachusetts insurers began providing an e-prescribing system with FDS to community-based practices. Using 18 months (October 1, 2003, to March 31, 2005) of administrative data, we conducted a pre-post study with concurrent controls. We first compared the change in the proportion of prescriptions for 3 formulary tiers before and after e-prescribing began, then developed multivariate longitudinal models to estimate the specific effect of e-prescribing when controlling for baseline differences between intervention and control prescribers. Potential savings were estimated using average medication costs by formulary tier. More than 1.5 million patients filled 17.4 million prescriptions during the study period. Multivariate models controlling for baseline differences between prescribers and for changes over time estimated that e-prescribing corresponded to a 3.3% increase (95% confidence interval, 2.7%-4.0%) in tier 1 prescribing. The proportion of prescriptions for tiers 2 and 3 (brand-name medications) decreased correspondingly. e-Prescriptions accounted for 20% of filled prescriptions in the intervention group. Based on average costs for private insurers, we estimated that e-prescribing with FDS at this rate could result in savings of $845,000 per 100,000 patients. Higher levels of e-prescribing use would increase these savings. Clinicians using e-prescribing with FDS were significantly more likely to prescribe tier 1 medications, and the potential financial savings were substantial. Widespread use of e-prescribing systems with FDS could result in reduced spending on medications.

  3. Cost-effectiveness of lung cancer screening and treatment methods: a systematic review of systematic reviews.

    PubMed

    Azar, Farbod Ebadifard; Azami-Aghdash, Saber; Pournaghi-Azar, Fatemeh; Mazdaki, Alireza; Rezapour, Aziz; Ebrahimi, Parvin; Yousefzadeh, Negar

    2017-06-19

    Due to extensive literature in the field of lung cancer and their heterogeneous results, the aim of this study was to systematically review of systematic reviews studies which reviewed the cost-effectiveness of various lung cancer screening and treatment methods. In this systematic review of systematic reviews study, required data were collected searching the following key words which selected from Mesh: "lung cancer", "lung oncology", "lung Carcinoma", "lung neoplasm", "lung tumors", "cost- effectiveness", "systematic review" and "Meta-analysis". The following databases were searched: PubMed, Cochrane Library electronic databases, Google Scholar, and Scopus. Two reviewers (RA and A-AS) evaluated the articles according to the checklist of "assessment of multiple systematic reviews" (AMSTAR) tool. Overall, information of 110 papers was discussed in eight systematic reviews. Authors focused on cost-effectiveness of lung cancer treatments in five systematic reviews. Targeted therapy options (bevacizumab, Erlotinib and Crizotinib) show an acceptable cost-effectiveness. Results of three studies failed to show cost-effectiveness of screening methods. None of the studies had used the meta-analysis method. The Quality of Health Economic Studies (QHES) tool and Drummond checklist were mostly used in assessing the quality of articles. Most perspective was related to the Payer (64 times) and the lowest was related to Social (11times). Most cases referred to Incremental analysis (82%) and also the lowest point of referral was related to Discounting (in 49% of the cases). The average quality score of included studies was calculated 9.2% from 11. Targeted therapy can be an option for the treatment of lung cancer. Evaluation of the cost-effectiveness of computerized tomographic colonography (CTC) in lung cancer screening is recommended. The perspective of the community should be more taken into consideration in studies of cost-effectiveness. Paying more attention to the topic of Discounting will be necessary in the studies.

  4. Twelve-month drug cost savings related to use of an electronic prescribing system with integrated decision support in primary care.

    PubMed

    McMullin, S Troy; Lonergan, Thomas P; Rynearson, Charles S

    2005-05-01

    We reported previously the results of a 6-month controlled trial in which the use of a commercially available electronic prescribing system with integrated clinical decision support and evidence-based message capability was associated with significantly lower primary care drug costs. The original study focused on new prescriptions, defined as claims for a medication that the patient had not received in the previous 12 months. The main objectives of this follow-up report were to (a) determine if the 6-month savings on new prescriptions were sustained during 12 months of follow-up, (b) evaluate the impact of the computerized decision support system (CDSS) on all pharmacy claims and per-member-per-month (PMPM) expenditures, and (c) evaluate the prescribing behaviors within 8 high-cost therapeutic categories that were frequently targeted by the electronic messages to prescribers to help verify that the drug cost savings were due to the recommendations in the electronic prescribing system. Two database queries were performed to identify additional pharmacy claims data for all Network Health Plan patients who were cared for by the 38 primary care clinicians (32 physicians, 4 nurse practitioners, and 2 physician assistants) included in our original 6-month study. This follow-up analysis (a) identified all new prescription claims for the 2 groups of clinicians throughout the 12-month follow-up period (June 2002 through May 2003) and (b) assessed all pharmacy claims during the same 12-month period to provide more complete savings estimates and to examine between-group differences in PMPM expenditures. During 12 months of follow-up, clinicians using the electronic prescribing system continued to have lower prescription costs than the controls. Clinicians using the electronic prescribing system had average costs for 26,674 new prescriptions that were dollar 4.12 lower (95% confidence interval, dollar 1.53-dollar 6.71; P=0.003) and PMPM expenditures that were dollar 0.57 lower than expected based on the changes observed for 24,507 new prescriptions written by clinicians in the control group. The average drug cost savings on new prescriptions were dollar 482 per prescriber per month (PPPM), based upon prescription cost and dollar 465 PPPM based upon PMPM analysis. When all pharmacy claims (156,429) were analyzed, the intervention group.s average prescription cost was dollar 2.57 lower and their PMPM expenditures were dollar 1.07 lower than expected based on the changes observed in the control group. The average drug cost savings on all pharmacy claims were dollar 863 PPPM based on average prescription cost and dollar 873 PPPM based on PMPM analysis. The proportion of prescriptions for highcost drugs that were the target of the CDSS messages to prescribers was a relative 17.5% lower among the intervention group (35.8%) compared with the control group (43.4%; P=0.03). An electronic prescribing system with integrated decision support shifted prescribing behavior away from high-cost therapies and significantly lowered prescription drug costs. The savings associated with altered prescribing behavior offset the monthly subscription cost of the system.

  5. Epidermal electronic systems for sensing and therapy

    NASA Astrophysics Data System (ADS)

    Lu, Nanshu; Ameri, Shideh K.; Ha, Taewoo; Nicolini, Luke; Stier, Andrew; Wang, Pulin

    2017-04-01

    Epidermal electronic system is a class of hair thin, skin soft, stretchable sensors and electronics capable of continuous and long-term physiological sensing and clinical therapy when applied on human skin. The high cost of manpower, materials, and photolithographic facilities associated with its manufacture limit the availability of disposable epidermal electronics. We have invented a cost and time effective, completely dry, benchtop "cut-and-paste" method for the green, freeform and portable manufacture of epidermal electronics within minutes. We have applied the "cut-and-paste" method to manufacture epidermal electrodes, hydration and temperature sensors, conformable power-efficient heaters, as well as cuffless continuous blood pressure monitors out of metal thin films, two-dimensional (2D) materials, and piezoelectric polymer sheets. For demonstration purpose, we will discuss three examples of "cut-and-pasted" epidermal electronic systems in this paper. The first will be submicron thick, transparent epidermal graphene electrodes that can be directly transferred to human skin like a temporary transfer tattoo and can measure electrocardiogram (ECG) with signal-to-noise ratio and motion artifacts on par with conventional gel electrodes. The second will be a chest patch which houses both electrodes and pressure sensors for the synchronous measurements of ECG and seismocardiogram (SCG) such that beat-to-beat blood pressure can be inferred from the time interval between the R peak of the ECG and the AC peak of the SCG. The last example will be a highly conformable, low power consumption epidermal heater for thermal therapy.

  6. Electron Beam-Cure Polymer Matrix Composites: Processing and Properties

    NASA Technical Reports Server (NTRS)

    Wrenn, G.; Frame, B.; Jensen, B.; Nettles, A.

    2001-01-01

    Researchers from NASA and Oak Ridge National Laboratory are evaluating a series of electron beam curable composites for application in reusable launch vehicle airframe and propulsion systems. Objectives are to develop electron beam curable composites that are useful at cryogenic to elevated temperatures (-217 C to 200 C), validate key mechanical properties of these composites, and demonstrate cost-saving fabrication methods at the subcomponent level. Electron beam curing of polymer matrix composites is an enabling capability for production of aerospace structures in a non-autoclave process. Payoffs of this technology will be fabrication of composite structures at room temperature, reduced tooling cost and cure time, and improvements in component durability. This presentation covers the results of material property evaluations for electron beam-cured composites made with either unidirectional tape or woven fabric architectures. Resin systems have been evaluated for performance in ambient, cryogenic, and elevated temperature conditions. Results for electron beam composites and similar composites cured in conventional processes are reviewed for comparison. Fabrication demonstrations were also performed for electron beam-cured composite airframe and propulsion piping subcomponents. These parts have been built to validate manufacturing methods with electron beam composite materials, to evaluate electron beam curing processing parameters, and to demonstrate lightweight, low-cost tooling options.

  7. A randomized trial found online questionnaires supplemented by postal reminders generated a cost-effective and generalizable sample but don't forget the reminders.

    PubMed

    Loban, Amanda; Mandefield, Laura; Hind, Daniel; Bradburn, Mike

    2017-12-01

    The objective of this study was to compare the response rates, data completeness, and representativeness of survey data produced by online and postal surveys. A randomized trial nested within a cohort study in Yorkshire, United Kingdom. Participants were randomized to receive either an electronic (online) survey questionnaire with paper reminder (N = 2,982) or paper questionnaire with electronic reminder (N = 2,855). Response rates were similar for electronic contact and postal contacts (50.9% vs. 49.7%, difference = 1.2%, 95% confidence interval: -1.3% to 3.8%). The characteristics of those responding to the two groups were similar. Participants nevertheless demonstrated an overwhelming preference for postal questionnaires, with the majority responding by post in both groups. Online survey questionnaire systems need to be supplemented with a postal reminder to achieve acceptable uptake, but doing so provides a similar response rate and case mix when compared to postal questionnaires alone. For large surveys, online survey systems may be cost saving. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Top-down Fabrication and Enhanced Active Area Electronic Characteristics of Amorphous Oxide Nanoribbons for Flexible Electronics.

    PubMed

    Jang, Hyun-June; Joong Lee, Ki; Jo, Kwang-Won; Katz, Howard E; Cho, Won-Ju; Shin, Yong-Beom

    2017-07-18

    Inorganic amorphous oxide semiconductor (AOS) materials such as amorphous InGaZnO (a-IGZO) possess mechanical flexibility and outstanding electrical properties, and have generated great interest for use in flexible and transparent electronic devices. In the past, however, AOS devices required higher activation energies, and hence higher processing temperatures, than organic ones to neutralize defects. It is well known that one-dimensional nanowires tend to have better carrier mobility and mechanical strength along with fewer defects than the corresponding two-dimensional films, but until now it has been difficult, costly, and impractical to fabricate such nanowires in proper alignments by either "bottom-up" growth techniques or by "top-down" e-beam lithography. Here we show a top-down, cost-effective, and scalable approach for the fabrication of parallel, laterally oriented AOS nanoribbons based on lift-off and nano-imprinting. High mobility (132 cm 2 /Vs), electrical stability, and transparency are obtained in a-IGZO nanoribbons, compared to the planar films of the same a-IGZO semiconductor.

  9. A comprehensive infectious disease management system.

    PubMed

    Marcu, Alex; Farley, John D

    2009-01-01

    An efficient electronic management system is now an essential tool for the successful management and monitoring of those affected by communicable infectious diseases (Human Immunodeficiency Virus - HIV, hepatitis C - HEP C) during the course of the treatment. The current methods which depend heavily on manual collecting, compiling and disseminating treatment information are labor-intensive and time consuming. Clinics specialized in the treatment of infectious diseases use a mix of electronic systems that fail to interact with each other, result in data duplication, and do not support treatment of the patient as a whole. The purpose of the Infectious Disease Management System is to reduce the administrative overhead associated with data collection and analysis while providing correlation abilities and decision support in accordance with defined treatment guidelines. This Infectious Disease Management System was developed to: Ensure cost effectiveness by means of low software licensing costs, Introduce a centralized mechanism of collecting and monitoring all infectious disease management data, Automate electronic retrieval of laboratory findings, Introduce a decision support mechanism as per treatment guidelines, Seamlessly integrate of application modules, Provide comprehensive reporting capabilities, Maintain a high level of user friendliness.

  10. Full-scale system impact analysis: Digital document storage project

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The Digital Document Storage Full Scale System can provide cost effective electronic document storage, retrieval, hard copy reproduction, and remote access for users of NASA Technical Reports. The desired functionality of the DDS system is highly dependent on the assumed requirements for remote access used in this Impact Analysis. It is highly recommended that NASA proceed with a phased, communications requirement analysis to ensure that adequate communications service can be supplied at a reasonable cost in order to validate recent working assumptions upon which the success of the DDS Full Scale System is dependent.

  11. Development of SiC Large Tapered Crystal Growth

    NASA Technical Reports Server (NTRS)

    Neudeck, Phil

    2010-01-01

    Majority of very large potential benefits of wide band gap semiconductor power electronics have NOT been realized due in large part to high cost and high defect density of commercial wafers. Despite 20 years of development, present SiC wafer growth approach is yet to deliver majority of SiC's inherent performance and cost benefits to power systems. Commercial SiC power devices are significantly de-rated in order to function reliably due to the adverse effects of SiC crystal dislocation defects (thousands per sq cm) in the SiC wafer.

  12. A Highly Efficient and Facile Approach for Fabricating Graphite Nanoplatelets

    NASA Astrophysics Data System (ADS)

    Van Thanh, Dang; Van Thien, Nguyen; Thang, Bui Hung; Van Chuc, Nguyen; Hong, Nguyen Manh; Trang, Bui Thi; Lam, Tran Dai; Huyen, Dang Thi Thu; Hong, Phan Ngoc; Minh, Phan Ngoc

    2016-05-01

    In this study, we report a highly efficient, convenient, and cost-effective technique for producing graphite nanoplatelets (GNPs) from plasma-expanded graphite oxides (PEGOs) obtained directly from low-cost, recycled graphite electrodes of used batteries, x-ray diffraction, Raman spectroscopy, and x-ray photoelectron spectroscopy confirmed the successful preparation of GNPs. Scanning electron microscopy revealed that the GNPs have lateral width from several hundreds of nanometers to 1.5 μm with an approximate thickness of 20-50 nm. These GNPs can serve as a precursor for the preparation of GNPs-based nanocomposite.

  13. Electronics Controls Assessment for the PATRIOT Air Conditioner System. Revision

    DTIC Science & Technology

    1986-04-28

    electronic controls in Army Air Conditioner Systems. This assessment used criteria which included: cost (initial and life cycle), efficiency, weight ...each of the twelve selected controllers as to cost and size Iqualifications was accomplished b) assigning reasonable weight factors according to the...following table:I COST SIZE5 WEIGHT FACTOR (Per Unit Price Range) (Volumetric Range) 1 Under $1000 Under 700 in 3 3 $1000 to $1500 700-1000 in 3 5 $1501

  14. In situ electrical and thermal monitoring of printed electronics by two-photon mapping.

    PubMed

    Pastorelli, Francesco; Accanto, Nicolò; Jørgensen, Mikkel; van Hulst, Niek F; Krebs, Frederik C

    2017-06-19

    Printed electronics is emerging as a new, large scale and cost effective technology that will be disruptive in fields such as energy harvesting, consumer electronics and medical sensors. The performance of printed electronic devices relies principally on the carrier mobility and molecular packing of the polymer semiconductor material. Unfortunately, the analysis of such materials is generally performed with destructive techniques, which are hard to make compatible with in situ measurements, and pose a great obstacle for the mass production of printed electronics devices. A rapid, in situ, non-destructive and low-cost testing method is needed. In this study, we demonstrate that nonlinear optical microscopy is a promising technique to achieve this goal. Using ultrashort laser pulses we stimulate two-photon absorption in a roll coated polymer semiconductor and map the resulting two-photon induced photoluminescence and second harmonic response. We show that, in our experimental conditions, it is possible to relate the total amount of photoluminescence detected to important material properties such as the charge carrier density and the molecular packing of the printed polymer material, all with a spatial resolution of 400 nm. Importantly, this technique can be extended to the real time mapping of the polymer semiconductor film, even during the printing process, in which the high printing speed poses the need for equally high acquisition rates.

  15. A Cost-Effectiveness Analysis of Blended Versus Face-to-Face Delivery of Evidence-Based Medicine to Medical Students.

    PubMed

    Maloney, Stephen; Nicklen, Peter; Rivers, George; Foo, Jonathan; Ooi, Ying Ying; Reeves, Scott; Walsh, Kieran; Ilic, Dragan

    2015-07-21

    Blended learning describes a combination of teaching methods, often utilizing digital technologies. Research suggests that learner outcomes can be improved through some blended learning formats. However, the cost-effectiveness of delivering blended learning is unclear. This study aimed to determine the cost-effectiveness of a face-to-face learning and blended learning approach for evidence-based medicine training within a medical program. The economic evaluation was conducted as part of a randomized controlled trial (RCT) comparing the evidence-based medicine (EBM) competency of medical students who participated in two different modes of education delivery. In the traditional face-to-face method, students received ten 2-hour classes. In the blended learning approach, students received the same total face-to-face hours but with different activities and additional online and mobile learning. Online activities utilized YouTube and a library guide indexing electronic databases, guides, and books. Mobile learning involved self-directed interactions with patients in their regular clinical placements. The attribution and differentiation of costs between the interventions within the RCT was measured in conjunction with measured outcomes of effectiveness. An incremental cost-effectiveness ratio was calculated comparing the ongoing operation costs of each method with the level of EBM proficiency achieved. Present value analysis was used to calculate the break-even point considering the transition cost and the difference in ongoing operation cost. The incremental cost-effectiveness ratio indicated that it costs 24% less to educate a student to the same level of EBM competency via the blended learning approach used in the study, when excluding transition costs. The sunk cost of approximately AUD $40,000 to transition to the blended model exceeds any savings from using the approach within the first year of its implementation; however, a break-even point is achieved within its third iteration and relative savings in the subsequent years. The sensitivity analysis indicates that approaches with higher transition costs, or staffing requirements over that of a traditional method, are likely to result in negative value propositions. Under the study conditions, a blended learning approach was more cost-effective to operate and resulted in improved value for the institution after the third year iteration, when compared to the traditional face-to-face model. The wider applicability of the findings are dependent on the type of blended learning utilized, staffing expertise, and educational context.

  16. Reduction in Unnecessary Clinical Laboratory Testing Through Utilization Management at a US Government Veterans Affairs Hospital.

    PubMed

    Konger, Raymond L; Ndekwe, Paul; Jones, Genea; Schmidt, Ronald P; Trey, Marty; Baty, Eric J; Wilhite, Denise; Munshi, Imtiaz A; Sutter, Bradley M; Rao, Maddamsetti; Bashir, Chowdry M

    2016-03-01

    To implement an electronic laboratory utilization management system (laboratory expert system [LES]) to provide safe and effective reductions in unnecessary clinical laboratory testing. The LES is a set of frequency filter subroutines within the Veterans Affairs hospital and laboratory information system that was formulated by an interdisciplinary medical team. Since implementing the LES, total test volume has decreased by a mean of 11.18% per year compared with our pre-LES test volume. This change was not attributable to fluctuations in outpatient visits or inpatient days of care. Laboratory cost savings were estimated at $151,184 and $163,751 for 2012 and 2013, respectively. A significant portion of these cost savings was attributable to reductions in high-volume, large panel testing. No adverse effects on patient care were reported, and mean length of stay for patients remained unchanged. Electronic laboratory utilization systems can effectively reduce unnecessary laboratory testing without compromising patient care. Published by Oxford University Press on behalf of the American Society for Clinical Pathology, 2016. This work is written by US Government employees and is in the public domain in the US.

  17. Cost-effective single-step carbon nanotube synthesis using microwave oven

    NASA Astrophysics Data System (ADS)

    Algadri, Natheer A.; Ibrahim, K.; Hassan, Z.; Bououdina, M.

    2017-08-01

    This paper reports the characterization of carbon nanotubes (CNTs) synthesised using a conventional microwave oven method, offering several advantages including fast, simple, low cost, and solvent free growth process. The procedure involves flattening of graphite/ferrocene mixture catalyst inside the microwave oven under ambient conditions for a very short duration of 5 s, which inhibits the loss factor of graphite and ferrocene. The effect of graphite/ferrocene mixture ratio for the synthesis of CNTs is investigated by transmission electron microscopy (TEM), field emission scanning electron microscopy (FESEM), x-ray diffraction (XRD), Raman spectroscopy and UV-NIR-Vis measurements. The samples produced using the different ratios contain nanotubes with an average diameter in the range 44-79 nm. The highest yield of CNTs is attained with graphite/ferrocene mixture ratio of 70:30. The lowest I D/I G ratio intensity as identified by Raman spectroscopy for 70:30 ratio indicates the improved crystallinity of CNTs. Due to the capillary effect of CNTs, Fe nanoparticles are found to be encapsulated inside the tubes at different positions along the tube length. The obtained results showed that the smaller the diameter of graphite and ferrocene favors the synthesis of graphene oxide upon microwave radiation.

  18. Current Driven Instabilities and Anomalous Mobility in Hall-effect Thrusters

    NASA Astrophysics Data System (ADS)

    Tran, Jonathan; Eckhardt, Daniel; Martin, Robert

    2017-10-01

    Due to the extreme cost of fully resolving the Debye length and plasma frequency, hybrid plasma simulations utilizing kinetic ions and quasi-steady state fluid electrons have long been the principle workhorse methodology for Hall-effect thruster (HET) modeling. Plasma turbulence and the resulting anomalous electron transport in HETs is a promising candidate for developing predictive models for the observed anomalous transport. In this work, we investigate the implementation of an anomalous electron cross field transport model for hybrid HET simulations such a HPHall. A theory for anomalous transport in HETs and current driven instabilities has been recently studied by Lafleur et al. This work has shown collective electron-wave scattering due to large amplitude azimuthal fluctuations of the electric field. We will further adapt the previous results for related current driven instabilities to electric propulsion relevant mass ratios and conduct a preliminary study of resolving this instability with a modified hybrid (fluid electron and kinetic ion) simulation with the hope of integration with established hybrid HET simulations. This work is supported by the Air Force Office of Scientific Research award FA9950-17RQCOR465.

  19. Annealing and anomalous high-energy electron irradiation effects in low-cost silicon N+P solar cells

    NASA Technical Reports Server (NTRS)

    Garlick, G. F. J.; Kachare, A. H.

    1981-01-01

    Silicon solar cells of N(+)P type were subjected to 1 MeV electron irradiation (up to 10 to the 16th electrons/sq cm) and then annealed at 450 C for 20 min or annealed with no electron irradiation. Electron irradiation resulted in a degradation of longer wavelength cell response, but produced a marked enhancement of response at shorter wavelengths with a peak change of 40% at 0.44 microns. Subsequent thermal anneal at 450 C reduced the long-wavelength degradation, but enhancement at shorter wavelengths persisted. Excitation at the shorter wavelengths was in the N(+)-diffused layer and in the junction region of the cell. Anneal of unirradiated cells produced shorter-wavelength enhancement with a similar peaking at 0.44 microns, but with a relative change of only 20%. More enhancement was produced in the longer wavelength region (up to 0.8 microns). These effects in the different cell regions are explained by a decrease in the interstitial oxygen-impurity complexes (deep recombination levels) and the formation of substantial oxygen-silicon vacancy centers (donors).

  20. Website creation and resource management: developing collaborative strategies for asynchronous interaction with library users.

    PubMed

    Hopkins, Mark E; Summers-Ables, Joy E; Clifton, Shari C; Coffman, Michael A

    2011-06-01

    To make electronic resources available to library users while effectively harnessing intellectual capital within the library, ultimately fostering the library's use of technology to interact asynchronously with its patrons (users). The methods used in the project included: (1) developing a new library website to facilitate the creation, management, accessibility, maintenance and dissemination of library resources; and (2) establishing ownership by those who participated in the project, while creating effective work allocation strategies through the implementation of a content management system that allowed the library to manage cost, complexity and interoperability. Preliminary results indicate that contributors to the system benefit from an increased understanding of the library's resources and add content valuable to library patrons. These strategies have helped promote the manageable creation and maintenance of electronic content in accomplishing the library's goal of interacting with its patrons. Establishment of a contributive system for adding to the library's electronic resources and electronic content has been successful. Further work will look at improving asynchronous interaction, particularly highlighting accessibility of electronic content and resources. © 2010 The authors. Health Information and Libraries Journal © 2010 Health Libraries Group.

  1. High-Efficiency Selective Electron Tunnelling in a Heterostructure Photovoltaic Diode.

    PubMed

    Jia, Chuancheng; Ma, Wei; Gu, Chunhui; Chen, Hongliang; Yu, Haomiao; Li, Xinxi; Zhang, Fan; Gu, Lin; Xia, Andong; Hou, Xiaoyuan; Meng, Sheng; Guo, Xuefeng

    2016-06-08

    A heterostructure photovoltaic diode featuring an all-solid-state TiO2/graphene/dye ternary interface with high-efficiency photogenerated charge separation/transport is described here. Light absorption is accomplished by dye molecules deposited on the outside surface of graphene as photoreceptors to produce photoexcited electron-hole pairs. Unlike conventional photovoltaic conversion, in this heterostructure both photoexcited electrons and holes tunnel along the same direction into graphene, but only electrons display efficient ballistic transport toward the TiO2 transport layer, thus leading to effective photon-to-electricity conversion. On the basis of this ipsilateral selective electron tunnelling (ISET) mechanism, a model monolayer photovoltaic device (PVD) possessing a TiO2/graphene/acridine orange ternary interface showed ∼86.8% interfacial separation/collection efficiency, which guaranteed an ultrahigh absorbed photon-to-current efficiency (APCE, ∼80%). Such an ISET-based PVD may become a fundamental device architecture for photovoltaic solar cells, photoelectric detectors, and other novel optoelectronic applications with obvious advantages, such as high efficiency, easy fabrication, scalability, and universal availability of cost-effective materials.

  2. Solving Boltzmann and Fokker-Planck Equations Using Sparse Representation

    DTIC Science & Technology

    2011-05-31

    material science. We have com- puted the electronic structure of 2D quantum dot system, and compared the efficiency with the benchmark software OCTOPUS . For...one self-consistent iteration step with 512 electrons, OCTOPUS costs 1091 sec, and selected inversion costs 9.76 sec. The algorithm exhibits

  3. Costs and Benefits of Electronic Portfolios in Teacher Education: Student Voices

    ERIC Educational Resources Information Center

    Wetzel, Keith; Strudler, Neal

    2006-01-01

    This descriptive study investigated the benefits and costs of using electronic portfolios (EPs) in preservice teacher education by examining the voices of students in six programs thought to be mature in their implementation. Benefits included opportunities to reflect, better access to and organization of professional documents, increased…

  4. Adaptive mechanical-wetting lens actuated by ferrofluids

    NASA Astrophysics Data System (ADS)

    Cheng, Hui-Chuan; Xu, Su; Liu, Yifan; Levi, Shoshana; Wu, Shin-Tson

    2011-04-01

    We report an adaptive mechanical-wetting lens actuated by ferrofluids. The ferrofluids works like a piston to pump liquids in and out from the lens chamber, which in turn reshapes the lens curvature and changes the focal length. Both positive and negative lenses are demonstrated experimentally. The ferrofluid-actuated mechanical-wetting lens exhibits some attractive features, such as high resolution, fast response time, low power consumption, simple structure and electronic control, weak gravity effect, and low cost. Its potential applications in medical imaging, surveillance, and commercial electronics are foreseeable.

  5. Semiconducting Nanocrystals in Mesostructured Thin Films for Optical and Opto-Electronic Device Applications

    DTIC Science & Technology

    2007-03-01

    with HF in methanol. For example, for 4.5 nm In0.91Ga0.09P nanoparticles in toluene, there is a dramatic increase in PL quantum efficiency from 8...opto-electronic device applications, for which quantum efficiencies above 50% are typically required for commercial cost-effectiveness. For the...InGaP nanocrystals……… 14 Figure 4: 2D double- quantum 31P NMR spectrum, 4.5 nm InGaP nanocrystals………….…… 15 Figure 5: TEM of of 10 nm, 5 nm

  6. Efficient calculation of atomic rate coefficients in dense plasmas

    NASA Astrophysics Data System (ADS)

    Aslanyan, Valentin; Tallents, Greg J.

    2017-03-01

    Modelling electron statistics in a cold, dense plasma by the Fermi-Dirac distribution leads to complications in the calculations of atomic rate coefficients. The Pauli exclusion principle slows down the rate of collisions as electrons must find unoccupied quantum states and adds a further computational cost. Methods to calculate these coefficients by direct numerical integration with a high degree of parallelism are presented. This degree of optimization allows the effects of degeneracy to be incorporated into a time-dependent collisional-radiative model. Example results from such a model are presented.

  7. J-PET detector system for studies of the electron-positron annihilations

    NASA Astrophysics Data System (ADS)

    Pawlik-Niedźwiecka, M.; Khreptak, O.; Gajos, A.; Wieczorek, A.; Alfs, D.; Bednarski, T.; Białas, P.; Curceanu, C.; Czerwiński, E.; Dulski, K.; Głowacz, B.; Gupta-Sharma, N.; Gorgol, M.; Hiesmayr, B. C.; Jasińska, B.; Kamińska, D.; Korcyl, G.; Kowalski, P.; Krzmień, W.; Krawczyk, N.; Kubicz, E.; Mohammed, M.; Niedźwiecki, Sz.; Raczyński, L.; Rudy, Z.; Silarski, M.; Wiślicki, W.; Zgardzińska, B.; Zieliński, M.; Moskal, P.

    2016-11-01

    Jagiellonian Positron Emission Tomograph (J-PET) has been recently constructed at the Jagiellonian University as a prototype of a cost-effective scanner for the metabolic imaging of the whole human body. J-PET detector is optimized for the measurement of momentum and polarization of photons from the electron-positron annihilations. It is built out of strips of plastic scintillators, forming three cylindrical layers. As detector of gamma quanta it will be used for studies of discrete symmetries and multiparticle entanglement of photons originating from the decays of ortho-positronium atoms.

  8. Design and application of a novel high precision and low cost electronic tachogenerator for sensor-based brushless direct current motor drivers.

    PubMed

    Ozgenel, Mehmet Cihat; Bal, Gungor; Uygun, Durmus

    2017-03-01

    This study presents a precise speed control method for Brushless Direct Current (BLDC) Motors using an electronic tachogenerator (ETg) instead of an electro-mechanical tachogenerator. Most commonly used three-phase BLDC motors have three position sensors for rotor position data to provide commutation among stator windings. Aforementioned position sensors are usually Hall-effect sensors delivering binary-high and binary-low data as long as the motor rotates. These binary sets from three Hall-effect sensors can be used as an analogue rotor speed signal for closed loop applications. Each position sensor signal is apart from 120 electrical degrees. By using an electronic circuitry, a combination of position sensor signals is converted to the analogue signal providing an input to a PI speed controller. To implement this, a frequency to voltage converter has been used in this study. Then, the analogue speed signal has been evaluated as rotor speed data in comparison with the reference speed. So, an ETg system has been successfully achieved in place of an electro-mechanical tachogenerator for BLDC motor speed control. The proposed ETg has been tested under various speed conditions on an experimental setup. Employed tests and obtained results show that the proposed low-cost speed feedback sub-system can be effectively used in BLDC motor drive systems. Through the proved method and designed sub-system, a new motor controller chip with a speed feedback capability has been aimed.

  9. Design and application of a novel high precision and low cost electronic tachogenerator for sensor-based brushless direct current motor drivers

    NASA Astrophysics Data System (ADS)

    Ozgenel, Mehmet Cihat; Bal, Gungor; Uygun, Durmus

    2017-03-01

    This study presents a precise speed control method for Brushless Direct Current (BLDC) Motors using an electronic tachogenerator (ETg) instead of an electro-mechanical tachogenerator. Most commonly used three-phase BLDC motors have three position sensors for rotor position data to provide commutation among stator windings. Aforementioned position sensors are usually Hall-effect sensors delivering binary-high and binary-low data as long as the motor rotates. These binary sets from three Hall-effect sensors can be used as an analogue rotor speed signal for closed loop applications. Each position sensor signal is apart from 120 electrical degrees. By using an electronic circuitry, a combination of position sensor signals is converted to the analogue signal providing an input to a PI speed controller. To implement this, a frequency to voltage converter has been used in this study. Then, the analogue speed signal has been evaluated as rotor speed data in comparison with the reference speed. So, an ETg system has been successfully achieved in place of an electro-mechanical tachogenerator for BLDC motor speed control. The proposed ETg has been tested under various speed conditions on an experimental setup. Employed tests and obtained results show that the proposed low-cost speed feedback sub-system can be effectively used in BLDC motor drive systems. Through the proved method and designed sub-system, a new motor controller chip with a speed feedback capability has been aimed.

  10. Nanoscale triboelectric-effect-enabled energy conversion for sustainably powering portable electronics.

    PubMed

    Wang, Sihong; Lin, Long; Wang, Zhong Lin

    2012-12-12

    Harvesting energy from our living environment is an effective approach for sustainable, maintenance-free, and green power source for wireless, portable, or implanted electronics. Mechanical energy scavenging based on triboelectric effect has been proven to be simple, cost-effective, and robust. However, its output is still insufficient for sustainably driving electronic devices/systems. Here, we demonstrated a rationally designed arch-shaped triboelectric nanogenerator (TENG) by utilizing the contact electrification between a polymer thin film and a metal thin foil. The working mechanism of the TENG was studied by finite element simulation. The output voltage, current density, and energy volume density reached 230 V, 15.5 μA/cm(2), and 128 mW/cm(3), respectively, and an energy conversion efficiency as high as 10-39% has been demonstrated. The TENG was systematically studied and demonstrated as a sustainable power source that can not only drive instantaneous operation of light-emitting diodes (LEDs) but also charge a lithium ion battery as a regulated power module for powering a wireless sensor system and a commercial cell phone, which is the first demonstration of the nanogenerator for driving personal mobile electronics, opening the chapter of impacting general people's life by nanogenerators.

  11. Solution Adsorption Formation of a π-Conjugated Polymer/Graphene Composite for High-Performance Field-Effect Transistors.

    PubMed

    Liu, Yun; Hao, Wei; Yao, Huiying; Li, Shuzhou; Wu, Yuchen; Zhu, Jia; Jiang, Lei

    2018-01-01

    Semiconducting polymers with π-conjugated electronic structures have potential application in the large-scale printable fabrication of high-performance electronic and optoelectronic devices. However, owing to their poor environmental stability and high-cost synthesis, polymer semiconductors possess limited device implementation. Here, an approach for constructing a π-conjugated polymer/graphene composite material to circumvent these limitations is provided, and then this material is patterned into 1D arrays. Driven by the π-π interaction, several-layer polymers can be adsorbed onto the graphene planes. The low consumption of the high-cost semiconductor polymers and the mass production of graphene contribute to the low-cost fabrication of the π-conjugated polymer/graphene composite materials. Based on the π-conjugated system, a reduced π-π stacking distance between graphene and the polymer can be achieved, yielding enhanced charge-transport properties. Owing to the incorporation of graphene, the composite material shows improved thermal stability. More generally, it is believed that the construction of the π-conjugated composite shows clear possibility of integrating organic molecules and 2D materials into microstructure arrays for property-by-design fabrication of functional devices with large area, low cost, and high efficiency. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Study of SPM tolerances of electronically compensated DML based systems.

    PubMed

    Papagiannakis, I; Klonidis, D; Birbas, Alexios N; Kikidis, J; Tomkos, I

    2009-05-25

    This paper experimentally investigates the effectiveness of electronic dispersion compensation (EDC) for signals limited by self phase modulation (SPM) and various dispersion levels. The sources considered are low-cost conventional directly modulated lasers (DMLs), fabricated for operation at 2.5 Gb/s but modulated at 10 Gb/s. Performance improvement is achieved by means of electronic feed-forward and decision-feedback equalization (FFE/DFE) at the receiver end. Experimental studies consider both transient and adiabatic chirp dominated DMLs sources. The improvement is evaluated in terms of required optical signal-to-noise ratio (ROSNR) for bit-error-rate (BER) values of 10(-3) versus launch power over uncompensated links of standard single mode fiber (SSMF).

  13. Policy and system strategies in promoting child health information systems, including the role of Medicaid, the state children's health insurance program, and public financing.

    PubMed

    MacTaggart, Patricia; Bagley, Bruce

    2009-01-01

    Government, through its unique roles as regulator, purchaser, provider, and facilitator, has an opportunity and an obligation to play a major role in accelerating the implementation of electronic health record systems and electronic health information exchange. Providers, who are expected to deliver appropriate care at designated locations at an appropriate cost, are dependent on health information technology for efficient effective health care. As state and federal governments move forward with health care purchasing reforms, they must take the opportunity to leverage policy and structure and to align incentives that enhance the potential for provider engagement in electronic health record adoption.

  14. Mechanical and Electronic Approaches to Improve the Sensitivity of Microcantilever Sensors

    PubMed Central

    Mutyala, Madhu Santosh Ku; Bandhanadham, Deepika; Pan, Liu; Pendyala, Vijaya Rohini; Ji, Hai-Feng

    2010-01-01

    Advances in the field of Micro Electro Mechanical Systems (MEMS) and their uses now offer unique opportunities in the design of ultrasensitive analytical tools. The analytical community continues to search for cost-effective, reliable, and even portable analytical techniques that can give reliable and fast response results for a variety of chemicals and biomolecules. Microcantilevers (MCLs) have emerged as a unique platform for label-free biosensor or bioassay. Several electronic designs, including piezoresistive, piezoelectric, and capacitive approaches, have been applied to measure the bending or frequency change of the MCLs upon exposure to chemicals. This review summarizes mechanical, fabrication, and electronics approaches to increase the sensitivity of microcantilever (MCL) sensors. PMID:20975987

  15. NCMS ESS 2000 Project

    NASA Technical Reports Server (NTRS)

    Gibbel, Mark; Bellamy, Marvin; DeSantis, Charlie; Hess, John; Pattok, Tracy; Quintero, Andrew; Silver, R.

    1996-01-01

    ESS 2000 has the vision of enhancing the knowledge necessary to implement cost-effective, leading-edge ESS technologies and procedures in order to increase U.S. electronics industry competitiveness. This paper defines EES and discusses the factors driving the project, the objectives of the project, its participants, the three phases of the project, the technologies involved, and project deliverables.

  16. The Utility of Electronic Mail Follow-Ups for Library Research.

    ERIC Educational Resources Information Center

    Roselle, Ann; Neufeld, Steven

    1998-01-01

    A survey of academic librarians determined that the use of e-mail in the follow-up stage of a library research project using mailed questionnaires was as effective as postal mail in speed and size of response. Discusses additional benefits (interpersonal communication, reduced time and costs) and drawbacks (time spent identifying messages…

  17. Methods of Use of an Online Economics Textbook

    ERIC Educational Resources Information Center

    Miller, Jon R.; Baker-Eveleth, Lori

    2010-01-01

    The rising cost of college textbooks over the last decade provides an opportunity for alternatives. Electronic or online textbooks are an effective substitute to the traditional paper-based textbooks, although students have been slow to transition to the new method. A custom, professor-written online textbook not only addresses the reduction in…

  18. New Technique for Fabrication of Scanning Single-Electron Transistor Microscopy Tips

    NASA Astrophysics Data System (ADS)

    Goodwin, Eric; Tessmer, Stuart

    Fabrication of glass tips for Scanning Single-Electron Transistor Microscopy (SSETM) can be expensive, time consuming, and inconsistent. Various techniques have been tried, with varying levels of success in regards to cost and reproducibility. The main requirement for SSETM tips is to have a sharp tip ending in a micron-scale flat face to allow for deposition of a quantum dot. Drawing inspiration from methods used to create tips from optical fibers for Near-Field Scanning Optical Microscopes, our group has come up with a quick and cost effective process for creating SSETM tips. By utilizing hydrofluoric acid to etch the tips and oleic acid to guide the etch profile, optical fiber tips with appropriate shaping can be rapidly prepared. Once etched, electric leads are thermally evaporated onto each side of the tip, while an aluminum quantum dot is evaporated onto the face. Preliminary results using various metals, oxide layers, and lead thicknesses have proven promising.

  19. First-principles electron transport with phonon coupling: Large scale at low cost

    NASA Astrophysics Data System (ADS)

    Gunst, Tue; Markussen, Troels; Palsgaard, Mattias L. N.; Stokbro, Kurt; Brandbyge, Mads

    2017-10-01

    Phonon-assisted tunneling plays a crucial role for electronic device performance and even more so with future size down-scaling. We show how one can include this effect in large-scale first-principles calculations using a single "special thermal displacement" (STD) of the atomic coordinates at almost the same cost as elastic transport calculations, by extending the recent method of Zacharias et al. [Phys. Rev. B 94, 075125 (2016), 10.1103/PhysRevB.94.075125] to the important case of Landauer conductance. We apply the method to ultrascaled silicon devices and demonstrate the importance of phonon-assisted band-to-band and source-to-drain tunneling. In a diode the phonons lead to a rectification ratio suppression in good agreement with experiments, while in an ultrathin body transistor the phonons increase off currents by four orders of magnitude, and the subthreshold swing by a factor of 4, in agreement with perturbation theory.

  20. Biosynthesis, characterization and antimicrobial action of silver nanoparticles from root bark extract of Berberislycium Royle.

    PubMed

    Mehmood, Ansar; Murtaza, Ghulam; Bhatti, Tariq Mahmood; Kausar, Rehana; Ahmed, Muhammad Jamil

    2016-01-01

    Various biological methods are being recognized for the fabrication of silver nanoparticles, which are used in several fields. The phytosynthesis of nanoparticles came out as a cost effective and enviro-friendly approach. When root bark extract of Berberis lycium was treated with silver ions, they reduced to silver nanoparticles, which were spherical, crystalline, size ranged from 10-100nm and capped by biomolecules. Synthesized silver nanoparticles were characterized by UV-visible spectroscopy, Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDX), Transmission Electron Microscopy (TEM), X-Ray Diffraction (XRD) and Fourier Transform Infra Red Spectroscopy (FTIR). The plant mediated synthesized silver nanoparticles showed pronounced antimicrobial activities against both Gram negative bacteria (Escherichia coli, Klebseilla pneumoniae, Pseudomonas aeruginosa) and Gram positive bacteria (Staphylococcus aureus and Bacillus subtilis). The plant mediated process proved to be non-toxic and low cost contender as reducing agent for synthesizing stable silver nanoparticles.

  1. Conductors and semiconductors for advanced organic electronics

    NASA Astrophysics Data System (ADS)

    Meyer-Friedrichsen, Timo; Elschner, Andreas; Keohan, Frank; Lövenich, Wilfried; Ponomarenko, Sergei A.

    2009-08-01

    The development of suitable materials for organic electronics is still one of the key points to access new application areas with this promising technology. Semiconductors based on thiophene chemistry show very high charge carrier mobilities. The functionalization with linker groups provided materials that built monomolecular layers of the semiconductors on the hydrolyzed oxide surface of a silicon-wafer. This approach lead to self-assembled mono-layer field-effect transistors (SAM-FETs) with mobilities of up to 0.04 cm2/Vs, which is comparable to the values of the respective bulk thin film. Transparent inorganic conductors like ITO are highly conductive but the costly processing and the brittleness hamper their use in cost-sensitive and/or flexible devices. Highly conductive PEDOT-grades have been developed with conductivities of up to 1000 S/cm which are easily applicable by printing techniques and can be used as ITO replacement in devices such as touch panels or organic photovoltaics.

  2. A low cost preparation of WO3 nanospheres film with improved thermal stability of gasochromic and its application in smart windows

    NASA Astrophysics Data System (ADS)

    Zhou, Baoyu; Feng, Wei; Gao, Guohua; Wu, Guangming; Chen, Yue; Li, Wen

    2017-11-01

    Porous WO3 nanospheres film was successfully synthesized by employing a low-cost and facile template-assisted sol-gel method. The effects of template agent (Pluronic F127) on structure, morphology and specific surface area were systematically studied by Fourier transform infrared (FTIR), x-ray diffraction (XRD), transmission electron microscopy (TEM), scanning electron microscopy (SEM), and N2 physisorption. It was found that F127 played a significant role in governing the morphology of WO3 sol clusters, and the optimal post-processing for ‘naked’ WO3 nanospheres film is acetone extraction and subsequent annealing treatment at 350 °C. As anticipated, the relative fast coloring/bleaching rates of WO3 nanospheres film are believed to be the results of porous microstructure and nanocrystalline, where provides much surface active position (166 m2 g-1) and shortens the proton diffusion distance. We believe that this unique approach to synthesize nanospheres structure may has beneficial effects on applications which also are based on insertion/extraction and diffusion abilities, such as supercapacitor, batteries and gas sensors.

  3. A virtual platform for electronic health record (EHR) education for nursing students: moving from in-house solutions to the cloud.

    PubMed

    Kushniruk, Andre W; Kuo, Mu-Hsing; Parapini, Eric; Borycki, Elizabeth M

    2014-01-01

    There is a need to develop cost effective ways to bring hands-on education about essential information technologies, such as electronic health record (EHR) systems to nursing students, nursing faculty and practitioners. This is especially the case as worldwide there is an increased deployment of these systems and they are transforming the practice of healthcare. However, due to technical, financial and knowledge limitations, many nursing schools and programs do not have an adequate way to bring such technology into their classes and curricula. In this paper we describe an approach to developing Web-based EHR education that allows students from any Web-accessible location to access and work with real EHR systems remotely over the Internet for learning purposes. In this paper we describe our work in moving this approach to a cloud-based solution to allow access to EHRs for educational purposes from any location with Web access and to do so in a way that is both educationally sound and cost effective.

  4. Columbia University's Informatics for Diabetes Education and Telemedicine (IDEATel) Project

    PubMed Central

    Shea, Steven; Starren, Justin; Weinstock, Ruth S.; Knudson, Paul E.; Teresi, Jeanne; Holmes, Douglas; Palmas, Walter; Field, Lesley; Goland, Robin; Tuck, Catherine; Hripcsak, George; Capps, Linnea; Liss, David

    2002-01-01

    The Columbia University Informatics for Diabetes Education and Telemedicine (IDEATel) Project is a four-year demonstration project funded by the Centers for Medicare and Medicaid Services with the overall goals of evaluating the feasibility, acceptability, effectiveness, and cost-effectiveness of telemedicine in the management of older patients with diabetes. The study is designed as a randomized controlled trial and is being conducted by a state-wide consortium in New York. Eligibility requires that participants have diabetes, are Medicare beneficiaries, and reside in federally designated medically underserved areas. A total of 1,500 participants will be randomized, half in New York City and half in other areas of the state. Intervention participants receive a home telemedicine unit that provides synchronous videoconferencing with a project-based nurse, electronic transmission of home fingerstick glucose and blood pressure data, and Web access to a project Web site. End points include glycosylated hemoglobin, blood pressure, and lipid levels; patient satisfaction; health care service utilization; and costs. The project is intended to provide data to help inform regulatory and reimbursement policies for electronically delivered health care services. PMID:11751803

  5. Remote Monitoring of Cardiac Implantable Electronic Devices (CIED)

    PubMed Central

    Zeitler, Emily P.; Piccini, Jonathan P.

    2016-01-01

    With increasing indications and access to cardiac implantable electronic devices (CIEDs) worldwide, the number of patients needing CIED follow up continues to rise. In parallel, the technology available for managing these devices has advanced considerably. In this setting, remote monitoring (RM) has emerged as a complement to routine in-office care. Rigorous studies, randomized and otherwise, have demonstrated advantages to CIED patient management systems which incorporates RM resulting in authoritative guidelines from relevant professional societies recommending RM for all eligible patients. In addition to clinical benefits, CIED management programs that include RM have been shown to be cost effective and associated with high patient satisfaction. Finally, RM programs hold promise for the future of CIED research in light of the massive data collected through RM databases converging with unprecedented computational capability. This review outlines the available data associated with clinical outcomes in patients managed with RM with an emphasis on randomized trials; the impact of RM on patient satisfaction, cost-effectiveness and healthcare utilization; and possible future directions for the use of RM in clinical practice and research. PMID:27134007

  6. Electronic Journals, the Internet, and Scholarly Communication.

    ERIC Educational Resources Information Center

    Kling, Rob; Callahan, Ewa

    2003-01-01

    Examines the role of the Internet in supporting scholarly communication via electronic journals. Topics include scholarly electronic communication; a typology of electronic journals; models of electronic documents and scholarly communication forums; publication speed; costs; pricing; access and searching; citations; interactivity; archiving and…

  7. Rational design of metal-organic electronic devices: A computational perspective

    NASA Astrophysics Data System (ADS)

    Chilukuri, Bhaskar

    Organic and organometallic electronic materials continue to attract considerable attention among researchers due to their cost effectiveness, high flexibility, low temperature processing conditions and the continuous emergence of new semiconducting materials with tailored electronic properties. In addition, organic semiconductors can be used in a variety of important technological devices such as solar cells, field-effect transistors (FETs), flash memory, radio frequency identification (RFID) tags, light emitting diodes (LEDs), etc. However, organic materials have thus far not achieved the reliability and carrier mobility obtainable with inorganic silicon-based devices. Hence, there is a need for finding alternative electronic materials other than organic semiconductors to overcome the problems of inferior stability and performance. In this dissertation, I research the development of new transition metal based electronic materials which due to the presence of metal-metal, metal-pi, and pi-pi interactions may give rise to superior electronic and chemical properties versus their organic counterparts. Specifically, I performed computational modeling studies on platinum based charge transfer complexes and d 10 cyclo-[M(mu-L)]3 trimers (M = Ag, Au and L = monoanionic bidentate bridging (C/N~C/N) ligand). The research done is aimed to guide experimental chemists to make rational choices of metals, ligands, substituents in synthesizing novel organometallic electronic materials. Furthermore, the calculations presented here propose novel ways to tune the geometric, electronic, spectroscopic, and conduction properties in semiconducting materials. In addition to novel material development, electronic device performance can be improved by making a judicious choice of device components. I have studied the interfaces of a p-type metal-organic semiconductor viz cyclo-[Au(mu-Pz)] 3 trimer with metal electrodes at atomic and surface levels. This work was aimed to guide the device engineers to choose the appropriate metal electrodes considering the chemical interactions at the interface. Additionally, the calculations performed on the interfaces provided valuable insight into binding energies, charge redistribution, change in the energy levels, dipole formation, etc., which are important parameters to consider while fabricating an electronic device. The research described in this dissertation highlights the application of unique computational modeling methods at different levels of theory to guide the experimental chemists and device engineers toward a rational design of transition metal based electronic devices with low cost and high performance.

  8. Effectiveness of low-cost electromagnetic shielding using nail-together galvanized steel: Test results. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Williams, P.F.; Kennedy, E.L.; McCormack, R.G.

    1992-09-01

    The sensitivity of modern electronic equipment has increased the need for costly electromagnetic shielding. To reduce this cost, the U.S. Army Construction Engineering Research Laboratories (USACERL) has developed a new concept for shielding design that uses 28-gauge galvanized steel and standard galvanized nails. In this study, an electromagnetically shielded structure using the concept was designed, built, and evaluated for shielding effectiveness. The galvanized material was mounted to the standard USACERL test aperture and nailed to the wooden module frame, and the shielding effectiveness of the new construction design was measured using radio frequency antennas and receivers. Evaluations showed that themore » nail-together structure proved adequate for many shielding applications. However, while the galvanized steel met most shielding application requirements, this process added multiple seams to the structure, which decreased shielding in many instances by as much as 40 dB. Electromagnetic shielding, Electromagnetic pulse C3I Facilities.« less

  9. Potential Effects of the Electronic Health Record on the Small Physician Practice: A Delphi Study.

    PubMed

    Sines, Chad C; Griffin, Gerald R

    2017-01-01

    The Health Information Technology for Economic and Clinical Health (HITECH) Act established the requirement of all medical practices to have certified electronic health records (EHRs). Some primary concerns that have been delaying implementation are issues of cost, revenue impact, and the effect on the patient encounter. Small physician practices (one to four physicians) account for 46 percent of all physicians. The purpose of this qualitative study using a modified Delphi research design was to examine the potential effect of the adoption of the EHR on revenue, unintended costs or savings, and changes in the patient encounter. Fifteen expert panelists completed the three-round survey process. The expert panelists reached a consensus that EHRs would reduce the number of patients seen per day, thereby reducing their revenue. Although the panelists limited their discussion on the effect of patient outcomes, their most dominant concern was the loss of face-to-face time with the patient. They felt that the use of an EHR would reduce the focus on the patient and potentially cause physicians to miss medical conditions. The results of this study indicate an avenue for EHR vendors to develop educational avenues to teach physicians how to optimize the EHR as well as to share success stories that demonstrate improved financial impact.

  10. Potential Effects of the Electronic Health Record on the Small Physician Practice: A Delphi Study

    PubMed Central

    Sines, Chad C.; Griffin, Gerald R.

    2017-01-01

    The Health Information Technology for Economic and Clinical Health (HITECH) Act established the requirement of all medical practices to have certified electronic health records (EHRs). Some primary concerns that have been delaying implementation are issues of cost, revenue impact, and the effect on the patient encounter. Small physician practices (one to four physicians) account for 46 percent of all physicians. The purpose of this qualitative study using a modified Delphi research design was to examine the potential effect of the adoption of the EHR on revenue, unintended costs or savings, and changes in the patient encounter. Fifteen expert panelists completed the three-round survey process. The expert panelists reached a consensus that EHRs would reduce the number of patients seen per day, thereby reducing their revenue. Although the panelists limited their discussion on the effect of patient outcomes, their most dominant concern was the loss of face-to-face time with the patient. They felt that the use of an EHR would reduce the focus on the patient and potentially cause physicians to miss medical conditions. The results of this study indicate an avenue for EHR vendors to develop educational avenues to teach physicians how to optimize the EHR as well as to share success stories that demonstrate improved financial impact. PMID:28566989

  11. Strategies and Opportunities to STOP Colon Cancer in Priority Populations: design of a cluster-randomized pragmatic trial.

    PubMed

    Coronado, Gloria D; Vollmer, William M; Petrik, Amanda; Taplin, Stephen H; Burdick, Timothy E; Meenan, Richard T; Green, Beverly B

    2014-07-01

    Colorectal cancer is the second-leading cause of cancer deaths in the United States. The Strategies and Opportunities to Stop Colorectal Cancer (STOP CRC) in Priority Populations study is a pragmatic trial and a collaboration between two research institutions and a network of more than 200 safety net clinics. The study will assess the effectiveness of a system-based intervention designed to improve the rates of colorectal-cancer screening using fecal immunochemical testing (FIT) in federally qualified health centers in Oregon and Northern California. STOP CRC is a cluster-randomized comparative-effectiveness pragmatic trial enrolling 26 clinics. Clinics will be randomized to one of two arms. Clinics in the intervention arm (1) will use an automated, data-driven, electronic health record-embedded program to identify patients due for colorectal screening and mail FIT kits (with pictographic instructions) to them; (2) will conduct an improvement process (e.g. Plan-Do-Study-Act) to enhance the adoption, reach, and effectiveness of the program. Clinics in the control arm will provide opportunistic colorectal-cancer screening to patients at clinic visits. The primary outcomes are: proportion of age- and screening-eligible patients completing a FIT within 12months; and cost, cost-effectiveness, and return on investment of the intervention. This large-scale pragmatic trial will leverage electronic health record information and existing clinic staff to enroll a broad range of patients, including many with historically low colorectal-cancer screening rates. If successful, the program will provide a model for a cost-effective and scalable method to raise colorectal-cancer screening rates. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. A randomised trial to demonstrate the effectiveness of electronic messages on sun protection behaviours.

    PubMed

    Szabó, Csanád; Ócsai, Henriette; Csabai, Márta; Kemény, Lajos

    2015-08-01

    Message exposure is effective at changing a variety of health behaviours. Our aim was to improve sun protection habits of a volunteer sample. We conducted a randomised, non-blinded, investigator-initiated trial (from 1st June to 31st August in 2011) on the effect of an electronic text-message system on sun protection behaviours. The assessments of 149 healthy volunteer participants took place at the Clinical Department of Dermatology and Allergology at the University of Szeged in Hungary. Psychological and medical assessments were also made. Total motivation scores for adherence to sunscreen use improved at a nearly significant level (t=-1.954, p=0.054). The intervention group used sunscreens more often than the other groups according to their sun exposure diaries (F=8.173, p<0.05) and their interview results (F=3.44, p<0.05). Using electronic messages offers an effective method to improve sun protection behaviours. Our intervention is a cost-effective method and it can easily be implemented at worksites. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. [Cooperation with the electronic medical record and accounting system of an actual dose of drug given by a radiology information system].

    PubMed

    Yamamoto, Hideo; Yoneda, Tarou; Satou, Shuji; Ishikawa, Toru; Hara, Misako

    2009-12-20

    By input of the actual dose of a drug given into a radiology information system, the system converting with an accounting system into a cost of the drug from the actual dose in the electronic medical record was built. In the drug master, the first unit was set as the cost of the drug, and we set the second unit as the actual dose. The second unit in the radiology information system was received by the accounting system through electronic medical record. In the accounting system, the actual dose was changed into the cost of the drug using the dose of conversion to the first unit. The actual dose was recorded on a radiology information system and electronic medical record. The actual dose was indicated on the accounting system, and the cost for the drug was calculated. About the actual dose of drug, cooperation of the information in a radiology information system and electronic medical record were completed. It was possible to decide the volume of drug from the correct dose of drug at the previous inspection. If it is necessary for the patient to have another treatment of medicine, it is important to know the actual dose of drug given. Moreover, authenticity of electronic medical record based on a statute has also improved.

  14. Costs and benefits of health information technology.

    PubMed

    Shekelle, Paul G; Morton, Sally C; Keeler, Emmett B

    2006-04-01

    An evidence report was prepared to assess the evidence base regarding benefits and costs of health information technology (HIT) systems, that is, the value of discrete HIT functions and systems in various healthcare settings, particularly those providing pediatric care. PubMed, the Cochrane Controlled Clinical Trials Register, and the Cochrane Database of Reviews of Effectiveness (DARE) were electronically searched for articles published since 1995. Several reports prepared by private industry were also reviewed. Of 855 studies screened, 256 were included in the final analyses. These included systematic reviews, meta-analyses, studies that tested a hypothesis, and predictive analyses. Each article was reviewed independently by two reviewers; disagreement was resolved by consensus. Of the 256 studies, 156 concerned decision support, 84 assessed the electronic medical record, and 30 were about computerized physician order entry (categories are not mutually exclusive). One hundred twenty four of the studies assessed the effect of the HIT system in the outpatient or ambulatory setting; 82 assessed its use in the hospital or inpatient setting. Ninety-seven studies used a randomized design. There were 11 other controlled clinical trials, 33 studies using a pre-post design, and 20 studies using a time series. Another 17 were case studies with a concurrent control. Of the 211 hypothesis-testing studies, 82 contained at least some cost data. We identified no study or collection of studies, outside of those from a handful of HIT leaders, that would allow a reader to make a determination about the generalizable knowledge of the study's reported benefit. Beside these studies from HIT leaders, no other research assessed HIT systems that had comprehensive functionality and included data on costs, relevant information on organizational context and process change, and data on implementation. A small body of literature supports a role for HIT in improving the quality of pediatric care. Insufficient data were available on the costs or cost-effectiveness of implementing such systems. The ability of Electronic Health Records (EHRs) to improve the quality of care in ambulatory care settings was demonstrated in a small series of studies conducted at four sites (three U.S. medical centers and one in the Netherlands). The studies demonstrated improvements in provider performance when clinical information management and decision support tools were made available within an EHR system, particularly when the EHRs had the capacity to store data with high fidelity, to make those data readily accessible, and to help translate them into context-specific information that can empower providers in their work. Despite the heterogeneity in the analytic methods used, all cost-benefit analyses predicted substantial savings from EHR (and health care information exchange and interoperability) implementation: The quantifiable benefits are projected to outweigh the investment costs. However, the predicted time needed to break even varied from three to as many as 13 years. HIT has the potential to enable a dramatic transformation in the delivery of health care, making it safer, more effective, and more efficient. Some organizations have already realized major gains through the implementation of multifunctional, interoperable HIT systems built around an EHR. However, widespread implementation of HIT has been limited by a lack of generalizable knowledge about what types of HIT and implementation methods will improve care and manage costs for specific health organizations. The reporting of HIT development and implementation requires fuller descriptions of both the intervention and the organizational/economic environment in which it is implemented.

  15. Next Generation Non-Vacuum, Maskless, Low Temperature Nanoparticle Ink Laser Digital Direct Metal Patterning for a Large Area Flexible Electronics

    PubMed Central

    Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P.; Ko, Seung Hwan

    2012-01-01

    Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition– and photolithography-based conventional metal patterning processes. The “digital” nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays. PMID:22900011

  16. Next generation non-vacuum, maskless, low temperature nanoparticle ink laser digital direct metal patterning for a large area flexible electronics.

    PubMed

    Yeo, Junyeob; Hong, Sukjoon; Lee, Daehoo; Hotz, Nico; Lee, Ming-Tsang; Grigoropoulos, Costas P; Ko, Seung Hwan

    2012-01-01

    Flexible electronics opened a new class of future electronics. The foldable, light and durable nature of flexible electronics allows vast flexibility in applications such as display, energy devices and mobile electronics. Even though conventional electronics fabrication methods are well developed for rigid substrates, direct application or slight modification of conventional processes for flexible electronics fabrication cannot work. The future flexible electronics fabrication requires totally new low-temperature process development optimized for flexible substrate and it should be based on new material too. Here we present a simple approach to developing a flexible electronics fabrication without using conventional vacuum deposition and photolithography. We found that direct metal patterning based on laser-induced local melting of metal nanoparticle ink is a promising low-temperature alternative to vacuum deposition- and photolithography-based conventional metal patterning processes. The "digital" nature of the proposed direct metal patterning process removes the need for expensive photomask and allows easy design modification and short turnaround time. This new process can be extremely useful for current small-volume, large-variety manufacturing paradigms. Besides, simple, scalable, fast and low-temperature processes can lead to cost-effective fabrication methods on a large-area polymer substrate. The developed process was successfully applied to demonstrate high-quality Ag patterning (2.1 µΩ·cm) and high-performance flexible organic field effect transistor arrays.

  17. 7 CFR 1709.8 - Electronic submission.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Electronic submission. 1709.8 Section 1709.8... AGRICULTURE ASSISTANCE TO HIGH ENERGY COST COMMUNITIES General Requirements § 1709.8 Electronic submission... announcement and grant agreements or if other regulations provide for electronic submission. Any electronic...

  18. 7 CFR 1709.8 - Electronic submission.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 11 2011-01-01 2011-01-01 false Electronic submission. 1709.8 Section 1709.8... AGRICULTURE ASSISTANCE TO HIGH ENERGY COST COMMUNITIES General Requirements § 1709.8 Electronic submission... announcement and grant agreements or if other regulations provide for electronic submission. Any electronic...

  19. 7 CFR 1709.8 - Electronic submission.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Electronic submission. 1709.8 Section 1709.8... AGRICULTURE ASSISTANCE TO HIGH ENERGY COST COMMUNITIES General Requirements § 1709.8 Electronic submission... announcement and grant agreements or if other regulations provide for electronic submission. Any electronic...

  20. 7 CFR 1709.8 - Electronic submission.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Electronic submission. 1709.8 Section 1709.8... AGRICULTURE ASSISTANCE TO HIGH ENERGY COST COMMUNITIES General Requirements § 1709.8 Electronic submission... announcement and grant agreements or if other regulations provide for electronic submission. Any electronic...

  1. 7 CFR 1709.8 - Electronic submission.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 11 2014-01-01 2014-01-01 false Electronic submission. 1709.8 Section 1709.8... AGRICULTURE ASSISTANCE TO HIGH ENERGY COST COMMUNITIES General Requirements § 1709.8 Electronic submission... announcement and grant agreements or if other regulations provide for electronic submission. Any electronic...

  2. Cell Phone-Based System (Chaak) for Surveillance of Immatures of Dengue Virus Mosquito Vectors

    PubMed Central

    LOZANO–FUENTES, SAUL; WEDYAN, FADI; HERNANDEZ–GARCIA, EDGAR; SADHU, DEVADATTA; GHOSH, SUDIPTO; BIEMAN, JAMES M.; TEP-CHEL, DIANA; GARCÍA–REJÓN, JULIÁN E.; EISEN, LARS

    2014-01-01

    Capture of surveillance data on mobile devices and rapid transfer of such data from these devices into an electronic database or data management and decision support systems promote timely data analyses and public health response during disease outbreaks. Mobile data capture is used increasingly for malaria surveillance and holds great promise for surveillance of other neglected tropical diseases. We focused on mosquito-borne dengue, with the primary aims of: 1) developing and field-testing a cell phone-based system (called Chaak) for capture of data relating to the surveillance of the mosquito immature stages, and 2) assessing, in the dengue endemic setting of Mérida, México, the cost-effectiveness of this new technology versus paper-based data collection. Chaak includes a desktop component, where a manager selects premises to be surveyed for mosquito immatures, and a cell phone component, where the surveyor receives the assigned tasks and captures the data. Data collected on the cell phone can be transferred to a central database through different modes of transmission, including near-real time where data are transferred immediately (e.g., over the Internet) or by first storing data on the cell phone for future transmission. Spatial data are handled in a novel, semantically driven, geographic information system. Compared with a pen-and-paper-based method, use of Chaak improved the accuracy and increased the speed of data transcription into an electronic database. The cost-effectiveness of using the Chaak system will depend largely on the up-front cost of purchasing cell phones and the recurring cost of data transfer over a cellular network. PMID:23926788

  3. Cost-effectiveness of drug monitoring of anti-TNF therapy in inflammatory bowel disease and rheumatoid arthritis: a systematic review.

    PubMed

    Martelli, Laura; Olivera, Pablo; Roblin, Xavier; Attar, Alain; Peyrin-Biroulet, Laurent

    2017-01-01

    Therapeutic drug monitoring (TDM) of anti-TNF is increasingly used to manage inflammatory bowel diseases (IBD) and rheumatoid arthritis (RA). The cost-effectiveness of this strategy is debated. All studies comparing the cost-effectiveness of a TDM-based strategy and an empirical dose management of anti-TNF in IBD or RA were screened. Studies were identified through the MEDLINE electronic database (up to July 2016), and annual international meeting abstracts were also manually reviewed. Seven studies were included: two randomized controlled trials (RCTs) enrolling 332 patients [247 Crohn's disease (CD) and 85 ulcerative colitis (UC)] and five modeling approaches. Four studies included only CD patients, one included both CD and UC patients, and two included only RA patients. Three studies compared the cost-effectiveness of the two strategies in patients with secondary infliximab (IFX) failure (dose-escalation strategy), one in patients in remission on optimized IFX (de-escalation strategy), one in patients starting adalimumab, and two in patients with clinical response to maintenance anti-TNF therapy. The two RCTs demonstrated that a TDM strategy led to major cost savings, ranging from 28 to 34 %. The three modeling approaches with regard to CD patients demonstrated cost savings ranging from $5396 over a 1-year period to €13,130 per patient at 5 years of follow-up. A TDM strategy also led to major cost savings in the two modeling approaches in RA patients. Available evidence indicates that a TDM strategy leads to major cost savings related to anti-TNF therapy in both IBD and RA patients, with no negative impact on efficacy.

  4. Economics of Electronic Publishing: Cost Issues--Comments on Session One Presentations.

    ERIC Educational Resources Information Center

    Shirrell, Robert

    This paper comments on three presentations (Janet Fisher, Malcolm Getz, and Bill Regier) at the Scholarly Communication and Technology Conference; it focuses on publisher costs, and also discusses the electronic publishing efforts undertaken at the University of Chicago Press. Janet Fisher, from MIT (Massachusetts Institute of Technology) Press,…

  5. Big Comsats for big jobs at low user cost. [considering wrist telephony, electronic mail transmission and educational television applications

    NASA Technical Reports Server (NTRS)

    Bekey, I.

    1979-01-01

    Three examples are used to illustrate what is possible with large space systems: (1) personal communications using wrist telephones, (2) electronic transmission of mail, and (3) wide dissemination of educational TV. Design concepts and costs are explored and compared to alternative ground-based concepts.

  6. Electronic Mail: Defining a Role for the U.S. Postal Service.

    ERIC Educational Resources Information Center

    McLaughlin, John F.

    Threatened by competitive diversification and by increasing costs, the United States Postal Service has investigated two potential cost reducing systems: (1) a microsystem which would provide electronic facsimile transmission between major markets and (2) a macrosystem which could take digital input such as utility bills and deliver a hardcopy to…

  7. 78 FR 5765 - Wireline Competition Bureau Releases Connect America Phase II Cost Model Virtual Workshop...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-28

    ... variation by geography; inter-office transport cost; voice capability; wire center facilities; sizing of... through traditional channels at the FCC, such as the Commission's Electronic Comment Filing System (ECFS... Electronic Comment Filing System (ECFS). In the meantime, parties are encouraged to examine both the Virtual...

  8. Costs and Benefits of Electronic Portfolios in Teacher Education: Faculty Perspectives

    ERIC Educational Resources Information Center

    Strudler, Neal; Wetzel, Keith

    2008-01-01

    This descriptive study investigated the benefits and costs of using electronic portfolios (EPs) in preservice teacher education. Grounded within change theory, the study examined the perspectives of faculty in six programs in which EPs have been used on a large scale for two or more years. Benefits identified include increased opportunities for…

  9. The NASA Electronic Parts and Packaging (NEPP) Program: Insertion of New Electronics Technologies

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.; Sampson, Michael J.

    2007-01-01

    This viewgraph presentation gives an overview of NASA Electronic Parts and Packaging (NEPP) Program's new electronics technology trends. The topics include: 1) The Changing World of Radiation Testing of Memories; 2) Even Application-Specific Tests are Costly!; 3) Hypothetical New Technology Part Qualification Cost; 4) Where we are; 5) Approaching FPGAs as a More Than a "Part" for Reliability; 6) FPGAs Beget Novel Radiation Test Setups; 7) Understanding the Complex Radiation Data; 8) Tracking Packaging Complexity and Reliability for FPGAs; 9) Devices Supporting the FPGA Need to be Considered; 10) Summary of the New Electronic Technologies and Insertion into Flight Programs Workshop; and 11) Highlights of Panel Notes and Comments

  10. The COMET Sleep Research Platform.

    PubMed

    Nichols, Deborah A; DeSalvo, Steven; Miller, Richard A; Jónsson, Darrell; Griffin, Kara S; Hyde, Pamela R; Walsh, James K; Kushida, Clete A

    2014-01-01

    The Comparative Outcomes Management with Electronic Data Technology (COMET) platform is extensible and designed for facilitating multicenter electronic clinical research. Our research goals were the following: (1) to conduct a comparative effectiveness trial (CET) for two obstructive sleep apnea treatments-positive airway pressure versus oral appliance therapy; and (2) to establish a new electronic network infrastructure that would support this study and other clinical research studies. The COMET platform was created to satisfy the needs of CET with a focus on creating a platform that provides comprehensive toolsets, multisite collaboration, and end-to-end data management. The platform also provides medical researchers the ability to visualize and interpret data using business intelligence (BI) tools. COMET is a research platform that is scalable and extensible, and which, in a future version, can accommodate big data sets and enable efficient and effective research across multiple studies and medical specialties. The COMET platform components were designed for an eventual move to a cloud computing infrastructure that enhances sustainability, overall cost effectiveness, and return on investment.

  11. The COMET Sleep Research Platform

    PubMed Central

    Nichols, Deborah A.; DeSalvo, Steven; Miller, Richard A.; Jónsson, Darrell; Griffin, Kara S.; Hyde, Pamela R.; Walsh, James K.; Kushida, Clete A.

    2014-01-01

    Introduction: The Comparative Outcomes Management with Electronic Data Technology (COMET) platform is extensible and designed for facilitating multicenter electronic clinical research. Background: Our research goals were the following: (1) to conduct a comparative effectiveness trial (CET) for two obstructive sleep apnea treatments—positive airway pressure versus oral appliance therapy; and (2) to establish a new electronic network infrastructure that would support this study and other clinical research studies. Discussion: The COMET platform was created to satisfy the needs of CET with a focus on creating a platform that provides comprehensive toolsets, multisite collaboration, and end-to-end data management. The platform also provides medical researchers the ability to visualize and interpret data using business intelligence (BI) tools. Conclusion: COMET is a research platform that is scalable and extensible, and which, in a future version, can accommodate big data sets and enable efficient and effective research across multiple studies and medical specialties. The COMET platform components were designed for an eventual move to a cloud computing infrastructure that enhances sustainability, overall cost effectiveness, and return on investment. PMID:25848590

  12. Simple glucose reduction route for one-step synthesis of copper nanofluids

    NASA Astrophysics Data System (ADS)

    Shenoy, U. Sandhya; Shetty, A. Nityananda

    2014-01-01

    One-step method has been employed in the synthesis of copper nanofluids. Copper nitrate is reduced by glucose in the presence of sodium lauryl sulfate. The synthesized particles are characterized by X-ray diffraction technique for the phase structure; electron diffraction X-ray analysis for chemical composition; transmission electron microscopy and field emission scanning electron microscopy for the morphology; Fourier-transform infrared spectroscopy and ultraviolet-visible spectroscopy for the analysis of ingredients of the solution. Thermal conductivity, sedimentation and rheological measurements have also been carried out. It is found that the reaction parameters have considerable effect on the size of the particle formed and rate of the reaction. The techniques confirm that the synthesized particles are copper. The reported method showed promising increase in the thermal conductivity of the base fluid and is found to be reliable, simple and cost-effective method for preparing heat transfer fluids with higher stability.

  13. Polyaniline as a material for hydrogen storage applications.

    PubMed

    Attia, Nour F; Geckeler, Kurt E

    2013-07-12

    The main challenge of commercialization of the hydrogen economy is the lack of convenient and safe hydrogen storage materials, which can adsorb and release a significant amount of hydrogen at ambient conditions. Finding and designing suitable cost-effective materials are vital requirements to overcome the drawbacks of investigated materials. Because of its outstanding electronic, thermal, and chemical properties, the electrically conducting polyaniline (PANI) has a high potential in hydrogen storage applications. In this review, the progress in the use of different structures of conducting PANI, its nanocomposites as well as activated porous materials based on PANI as hydrogen storage materials is presented and discussed. The effect of the unique electronic properties based on the π-electron system in the backbone of these materials in view of the hydrogen uptake and the relevant mechanisms are highlighted. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. An embedded measurement system for the electrical characterization of EGFET as a pH sensor

    NASA Astrophysics Data System (ADS)

    Diniz Batista, Pablo

    2014-02-01

    This work presents the development of an electronic system for the electrical characterization of pH sensors based on the extended gate field effect transistor (EGFET). We designed an electronic circuit with a microcontroller (PIC15F14K50) as the main component in order to provide two programmable output voltages as well as circuits to measure electric current and voltages. The instrument performance analysis was carried out using a glass electrode as a sensitive membrane for investigating the EGFET operation as a pH sensor. The results show that the system is an alternative to the commercial equipment for the electrical characterization of sensors based on field effect devices. In addition, some of the key features expected of this electronic module are: low cost, flexibility, portability and communication with a personal computer using a USB port.

  15. Electronic structure of stoichiometric and reduced ZnO from periodic relativistic all electron hybrid density functional calculations using numeric atom-centered orbitals.

    PubMed

    Viñes, Francesc; Illas, Francesc

    2017-03-30

    The atomic and electronic structure of stoichiometric and reduced ZnO wurtzite has been studied using a periodic relativistic all electron hybrid density functional (PBE0) approach and numeric atom-centered orbital basis set with quality equivalent to aug-cc-pVDZ. To assess the importance of relativistic effects, calculations were carried out without and with explicit inclusion of relativistic effects through the zero order regular approximation. The calculated band gap is ∼0.2 eV smaller than experiment, close to previous PBE0 results including relativistic calculation through the pseudopotential and ∼0.25 eV smaller than equivalent nonrelativistic all electron PBE0 calculations indicating possible sources of error in nonrelativistic all electron density functional calculations for systems containing elements with relatively high atomic number. The oxygen vacancy formation energy converges rather fast with the supercell size, the predicted value agrees with previously hybrid density functional calculations and analysis of the electronic structure evidences the presence of localized electrons at the vacancy site with a concomitant well localized peak in the density of states ∼0.5 eV above the top of the valence band and a significant relaxation of the Zn atoms near to the oxygen vacancy. Finally, present work shows that accurate results can be obtained in systems involving large supercells containing up to ∼450 atoms using a numeric atomic-centered orbital basis set within a full all electron description including scalar relativistic effects at an affordable cost. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Diamond bio electronics.

    PubMed

    Linares, Robert; Doering, Patrick; Linares, Bryant

    2009-01-01

    The use of diamond for advanced applications has been the dream of mankind for centuries. Until recently this dream has been realized only in the use of diamond for gemstones and abrasive applications where tons of diamonds are used on an annual basis. Diamond is the material system of choice for many applications, but its use has historically been limited due to the small size, high cost, and inconsistent (and typically poor) quality of available diamond materials until recently. The recent development of high quality, single crystal diamond crystal growth via the Chemical Vapor Deposition (CVD) process has allowed physcists and increasingly scientists in the life science area to think beyond these limitations and envision how diamond may be used in advanced applications ranging from quantum computing, to power generation and molecular imaging, and eventually even diamond nano-bots. Because of diamond's unique properties as a bio-compatible material, better understanding of diamond's quantum effects and a convergence of mass production, semiconductor-like fabrication process, diamond now promises a unique and powerful key to the realization of the bio-electronic devices being envisioned for the new era of medical science. The combination of robust in-the-body diamond based sensors, coupled with smart bio-functionalized diamond devices may lead to diamond being the platform of choice for bio-electronics. This generation of diamond based bio-electronic devices would contribute substantially to ushering in a paradigm shift for medical science, leading to vastly improved patient diagnosis, decrease of drug development costs and risks, and improved effectiveness of drug delivery and gene therapy programs through better timed and more customized solutions.

  17. Metal Oxide Thin Film Transistors on Paper Substrate: Fabrication, Characterization, and Printing Process

    NASA Astrophysics Data System (ADS)

    Choi, Nack-Bong

    Flexible electronics is an emerging next-generation technology that offers many advantages such as light weight, durability, comfort, and flexibility. These unique features enable many new applications such as flexible display, flexible sensors, conformable electronics, and so forth. For decades, a variety of flexible substrates have been demonstrated for the application of flexible electronics. Most of them are plastic films and metal foils so far. For the fundamental device of flexible circuits, thin film transistors (TFTs) using poly silicon, amorphous silicon, metal oxide and organic semiconductor have been successfully demonstrated. Depending on application, low-cost and disposable flexible electronics will be required for convenience. Therefore it is important to study inexpensive substrates and to explore simple processes such as printing technology. In this thesis, paper is introduced as a new possible substrate for flexible electronics due to its low-cost and renewable property, and amorphous indium gallium zinc oxide (a-IGZO) TFTs are realized as the promising device on the paper substrate. The fabrication process and characterization of a-IGZO TFT on the paper substrate are discussed. a-IGZO TFTs using a polymer gate dielectric on the paper substrate demonstrate excellent performances with field effect mobility of ˜20 cm2 V-1 s-1, on/off current ratio of ˜106, and low leakage current, which show the enormous potential for flexible electronics application. In order to complement the n-channel a-IGZO TFTs and then enable complementary metal-oxide semiconductor (CMOS) circuit architectures, cuprous oxide is studied as a candidate material of p-channel oxide TFTs. In this thesis, a printing process is investigated as an alternative method for the fabrication of low-cost and disposable electronics. Among several printing methods, a modified offset roll printing that prints high resolution patterns is presented. A new method to fabricate a high resolution printing plate is investigated and the most favorable condition to transfer ink from a blanket to a cliche is studied. Consequently, a high resolution cliche is demonstrated and the printed patterns of 10mum width and 6mum line spacing are presented. In addition, the top gate a-IGZO TFTs with channel width/length of 12/6mum is successfully demonstrated by printing etch-resists. This work validates the compatibility of a-IGZO TFT on paper substrate for the disposable microelectronics application and presents the potential of low-cost and high resolution printing technology.

  18. Economic Evaluation of Intravenous Immunoglobulin plus Corticosteroids for the Treatment of Steroid-Resistant Chronic Inflammatory Demyelinating Polyradiculoneuropathy in Thailand.

    PubMed

    Bamrungsawad, Naruemon; Upakdee, Nilawan; Pratoomsoot, Chayanin; Sruamsiri, Rosarin; Dilokthornsakul, Piyameth; Dechanont, Supinya; Wu, David Bin-Chia; Dejthevaporn, Charungthai; Chaiyakunapruk, Nathorn

    2016-07-01

    Intravenous immunoglobulin (IVIG) has been recommended for steroid-resistant chronic inflammatory demyelinating polyradiculoneuropathy (CIDP). The treatment, however, is very costly to healthcare system, and there remains no evidence of its economic justifiability. This study aimed to conduct an economic evaluation (EE) of IVIG plus corticosteroids in steroid-resistant CIDP in Thailand. A Markov model was constructed to estimate the lifetime costs and outcomes for IVIG plus corticosteroids in comparison with immunosuppressants plus corticosteroids in steroid-resistant CIDP patients from a societal perspective. Efficacy and utility data were obtained from clinical literature, meta-analyses, medical record reviews, and patient interviews. Cost data were obtained from list prices, an electronic hospital database, published source, and patient interviews. All costs [in 2015 US dollars (US$)] and outcomes were discounted at 3 % annually. One-way and probabilistic sensitivity analyses were conducted. In the base-case, the incremental costs and quality-adjusted life years (QALYs) of IVIG plus corticosteroids versus immunosuppressants plus corticosteroids were US$2112.02 and 1.263 QALYs, respectively, resulting in an incremental cost-effectiveness ratio (ICER) of US$1672.71 per QALY gained. Sensitivity analyses revealed that the utility value of disabled patients was the greatest influence on ICER. At a societal willingness-to-pay threshold in Thailand of US$4672 per QALY gained, IVIG plus corticosteroids had a 92.1 % probability of being cost effective. At a threshold of US$4672 per QALY gained, IVIG plus corticosteroids is considered a cost-effective treatment for steroid-resistant CIDP patients in Thailand.

  19. 2 CFR 200.461 - Publication and printing costs.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 2 Grants and Agreements 1 2014-01-01 2014-01-01 false Publication and printing costs. 200.461... Cost § 200.461 Publication and printing costs. (a) Publication costs for electronic and print media... activities of the non-Federal entity. (b) Page charges for professional journal publications are allowable...

  20. A Novel Electronic Data Collection System for Large-Scale Surveys of Neglected Tropical Diseases

    PubMed Central

    King, Jonathan D.; Buolamwini, Joy; Cromwell, Elizabeth A.; Panfel, Andrew; Teferi, Tesfaye; Zerihun, Mulat; Melak, Berhanu; Watson, Jessica; Tadesse, Zerihun; Vienneau, Danielle; Ngondi, Jeremiah; Utzinger, Jürg; Odermatt, Peter; Emerson, Paul M.

    2013-01-01

    Background Large cross-sectional household surveys are common for measuring indicators of neglected tropical disease control programs. As an alternative to standard paper-based data collection, we utilized novel paperless technology to collect data electronically from over 12,000 households in Ethiopia. Methodology We conducted a needs assessment to design an Android-based electronic data collection and management system. We then evaluated the system by reporting results of a pilot trial and from comparisons of two, large-scale surveys; one with traditional paper questionnaires and the other with tablet computers, including accuracy, person-time days, and costs incurred. Principle Findings The electronic data collection system met core functions in household surveys and overcame constraints identified in the needs assessment. Pilot data recorders took 264 (standard deviation (SD) 152 sec) and 260 sec (SD 122 sec) per person registered to complete household surveys using paper and tablets, respectively (P = 0.77). Data recorders felt a lack of connection with the interviewee during the first days using electronic devices, but preferred to collect data electronically in future surveys. Electronic data collection saved time by giving results immediately, obviating the need for double data entry and cross-correcting. The proportion of identified data entry errors in disease classification did not differ between the two data collection methods. Geographic coordinates collected using the tablets were more accurate than coordinates transcribed on a paper form. Costs of the equipment required for electronic data collection was approximately the same cost incurred for data entry of questionnaires, whereas repeated use of the electronic equipment may increase cost savings. Conclusions/Significance Conducting a needs assessment and pilot testing allowed the design to specifically match the functionality required for surveys. Electronic data collection using an Android-based technology was suitable for a large-scale health survey, saved time, provided more accurate geo-coordinates, and was preferred by recorders over standard paper-based questionnaires. PMID:24066147

  1. A systematic review of economic evaluations of seasonal influenza vaccination for the elderly population in the European Union.

    PubMed

    Shields, Gemma E; Elvidge, Jamie; Davies, Linda M

    2017-06-10

    The Council of the European Union (EU) has recommended that action should be taken to increase influenza vaccination in the elderly population. The aims were to systematically review and critically appraise economic evaluations for influenza vaccination in the elderly population in the EU. Electronic searches of the NHS Economic Evaluation, Health Technology Assessment, MEDLINE and Embase databases were run to identify full economic evaluations. Two levels of screening were used, with explicit inclusion criteria applied by two independent reviewers at each stage. Prespecified data extraction and critical appraisal were performed on identified studies. Results were summarised qualitatively. Of the 326 search results, screening identified eight relevant studies. Results varied widely, with the incremental cost-effectiveness ratio ranging from being both more effective and cheaper than no intervention to costing €4 59 350 per life-year gained. Cost-effectiveness was most sensitive to variations in influenza strain, vaccination type and strategy, population and modelling characteristics. Most studies suggest that vaccination is cost-effective (seven of eight studies identified at least one cost-effective scenario). All but one study used economic models to synthesise data from different sources. The results are uncertain due to the methods used and the relevance and robustness of the data used. Sensitivity analysis to explore these aspects was limited. Integrated, controlled prospective clinical and economic evaluations and surveillance data are needed to improve the evidence base. This would allow more advanced modelling techniques to characterise the epidemiology of influenza more accurately and improve the robustness of cost-effectiveness estimates. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Two-Year Operational Evaluation Of A Consumer Electronics-Based Data Acquisition System For Equipment Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Hoy, Blake W.; Phillips, Larry D.; Wetherington Jr, G Randall

    Oak Ridge National Laboratory (ORNL) has performed a two-year evaluation of the performance of an in-house developed consumer electronics-based data acquisition system (DAS). The main advantage of this approach compared to conventional instrumentation grade systems is cost; instrument grade data acquisition systems average costs range from $800 to $2,000 per channel compared to a range of $200 - $400 per channel for a consumer electronics-based system. The DAS is operated as a full-time in-situ vibration monitor. The resulting data stream is streamed over the ORNL network, at an aggregate rate of approximately 2 megabytes/s, to a Linux server. The servermore » includes the capability to implement event-triggered data stores, as well as real-time files for the implementation of continuous display monitoring of the spectra. Detailed spectral analysis is performed post event. The DAS is installed on a large industrial chiller and cooling water pump associated with ORNL’s Titan supercomputer. These mechanical systems include rotating components that operate at fundamental frequencies within the range of 30 Hz to over 3 KHz. Evaluation of the DAS data over a two-year operating period leads to the conclusion that for many industrial processes this system could form the basis for a cost effective means of obtaining operating health data in real time from rotating machinery. The deployment has also shown that the DAS technology is reliable. Furthermore, because the cost of the DAS is low, the other significant advantage of this approach is that the DAS can be deployed in a dedicated manner and operated on a full-time basis.« less

  3. Demand management: an audit of chemical pathology test rejections by an electronic gate-keeping system at an academic hospital in Cape Town.

    PubMed

    Smit, Ida; Zemlin, Annalise E; Erasmus, Rajiv T

    2015-07-01

    Demand management is an area of laboratory activity, which is becoming increasingly important. Within the health-care system, demand management can be defined as the use of health resources to maximise its utility. Tygerberg Hospital has introduced an electronic gate-keeping system. Chemistry tests which generate the highest cost are subjected to this system and may be automatically rejected according to a set of rules. This study aimed: (1) to identify the number of chemistry tests rejected by the eGK; (2) to identify which of these rejected tests were subsequently restored and (3) to assess the impact of rejections on clinical outcome and cost-saving. A retrospective audit was conducted to determine the number of chemistry tests rejected and subsequently restored over a 6-month period. The case-notes of patients for whom requested tests previously rejected had been restored were randomly selected and investigated to assess clinical impact. Any cost-saving was calculated. A total of 68,480 tests were subjected to gate-keeping, and 4605 tests (6.7%) were rejected while 679 (14.7%) of these were restored by the requestor phoning the laboratory after obtaining authorisation. After examining a subset of clinical notes it was found that in most cases (80%), patient care was unaffected. The total cost saved was £ 25,387. The majority of the rejected tests were unnecessary and following rejection, real savings were made. Electronic gate-keeping is a simple, effective and sustainable method of demand management. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. The cost of implementing inpatient bar code medication administration.

    PubMed

    Sakowski, Julie Ann; Ketchel, Alan

    2013-02-01

    To calculate the costs associated with implementing and operating an inpatient bar-code medication administration (BCMA) system in the community hospital setting and to estimate the cost per harmful error prevented. This is a retrospective, observational study. Costs were calculated from the hospital perspective and a cost-consequence analysis was performed to estimate the cost per preventable adverse drug event averted. Costs were collected from financial records and key informant interviews at 4 not-for profit community hospitals. Costs included direct expenditures on capital, infrastructure, additional personnel, and the opportunity costs of time for existing personnel working on the project. The number of adverse drug events prevented using BCMA was estimated by multiplying the number of doses administered using BCMA by the rate of harmful errors prevented by interventions in response to system warnings. Our previous work found that BCMA identified and intercepted medication errors in 1.1% of doses administered, 9% of which potentially could have resulted in lasting harm. The cost of implementing and operating BCMA including electronic pharmacy management and drug repackaging over 5 years is $40,000 (range: $35,600 to $54,600) per BCMA-enabled bed and $2000 (range: $1800 to $2600) per harmful error prevented. BCMA can be an effective and potentially cost-saving tool for preventing the harm and costs associated with medication errors.

  5. Quantum-Sequencing: Fast electronic single DNA molecule sequencing

    NASA Astrophysics Data System (ADS)

    Casamada Ribot, Josep; Chatterjee, Anushree; Nagpal, Prashant

    2014-03-01

    A major goal of third-generation sequencing technologies is to develop a fast, reliable, enzyme-free, high-throughput and cost-effective, single-molecule sequencing method. Here, we present the first demonstration of unique ``electronic fingerprint'' of all nucleotides (A, G, T, C), with single-molecule DNA sequencing, using Quantum-tunneling Sequencing (Q-Seq) at room temperature. We show that the electronic state of the nucleobases shift depending on the pH, with most distinct states identified at acidic pH. We also demonstrate identification of single nucleotide modifications (methylation here). Using these unique electronic fingerprints (or tunneling data), we report a partial sequence of beta lactamase (bla) gene, which encodes resistance to beta-lactam antibiotics, with over 95% success rate. These results highlight the potential of Q-Seq as a robust technique for next-generation sequencing.

  6. How School Counselors Could Benefit from E-Government Solutions: The Case of Paperwork.

    ERIC Educational Resources Information Center

    Sabella, Russell A.

    The U.S. government has tackled many problems which have plagued its effectiveness and efficiency to serve its citizens with technology solutions. Electronic government, or e-Government, is the expression used to describe how the U.S. government attempts to increase productivity and reduce costs by using Internet-based technology. More…

  7. A Study of the Relationship of Communication Technology Configurations in Virtual Research Environments and Effectiveness of Collaborative Research

    ERIC Educational Resources Information Center

    Ahmed, Iftekhar

    2009-01-01

    Virtual Research Environments (VRE) are electronic meeting places for interaction among scientists created by combining software tools and computer networking. Virtual teams are enjoying increased importance in the conduct of scientific research because of the rising cost of traditional scientific scholarly communication, the growing importance of…

  8. Do Professors Dream of Electronic Students? Faculty Anxiety and the New Information Technologies.

    ERIC Educational Resources Information Center

    Novek, Eleanor M.

    This survey of faculty attitudes toward technology calls for more critical dialogue on the uses, effects and hidden costs of information technology in the classroom and the national political economy. A survey was administered to 250 faculty members (135 were returned) at a northeastern university. The comments of respondents fell into two main…

  9. Space Shuttle Lightning Protection

    NASA Technical Reports Server (NTRS)

    Suiter, D. L.; Gadbois, R. D.; Blount, R. L.

    1979-01-01

    The technology for lightning protection of even the most advanced spacecraft is available and can be applied through cost-effective hardware designs and design-verification techniques. In this paper, the evolution of the Space Shuttle Lightning Protection Program is discussed, including the general types of protection, testing, and anlayses being performed to assess the lightning-transient-damage susceptibility of solid-state electronics.

  10. How to Lose Money Electronically: Word Processing and the Social Structure of Scholarly Publishing.

    ERIC Educational Resources Information Center

    Miles, Jack

    1984-01-01

    Addresses the issue of possible savings of time and money for authors and publishers resulting from author word processing and automation of scholarly book publishing industry. Automation and taxes, newspaper publishing, editing, routine expenses in the copy editing of word-processed works, and the effect on costs for libraries are covered. (EJS)

  11. The Perplexing Role of Learner Control in E-Learning: Will Learning and Transfer Benefit or Suffer?

    ERIC Educational Resources Information Center

    Granger, Benjamin P.; Levine, Edward L.

    2010-01-01

    The appeal of e-learning is not surprising given its many proposed advantages (e.g. flexibility, responsiveness to trainees' individual needs, potential cost-effectiveness). However, as pointed out by Ruel et al., academic research in support of the proposed advantages of electronic human resource management systems is scarce. Although this is…

  12. Chronic Disease Risks in Young Adults with Autism Spectrum Disorder: Forewarned Is Forearmed

    ERIC Educational Resources Information Center

    Tyler, Carl V.; Schramm, Sarah C.; Karafa, Matthew; Tang, Anne S.; Jain, Anil K.

    2011-01-01

    An emerging, cost-effective method to examine prevalent and future health risks of persons with disabilities is electronic health record (EHR) analysis. As an example, a case-control EHR analysis of adults with autism spectrum disorder receiving primary care through the Cleveland Clinic from 2005 to 2008 identified 108 adults with autism spectrum…

  13. Effect of strain and diet on growth performance characteristics and relative expression of genes coding for electron transport chain in channel catfish

    USDA-ARS?s Scientific Manuscript database

    The major cost in aquaculture production systems is feed, and the use of biotechnology approaches to identify fishes with superior feed efficiency (FE) may have a positive influence on profitability. There been little use of genetically based technologies to assess FE in culture fishes. Mitochondria...

  14. We Can Have It All: Improved Surveillance Outcomes and Decreased Personnel Costs Associated With Electronic Reportable Disease Surveillance, North Carolina, 2010

    PubMed Central

    DiBiase, Lauren; Fangman, Mary T.; Fleischauer, Aaron T.; Waller, Anna E.; MacDonald, Pia D. M.

    2013-01-01

    Objectives. We assessed the timeliness, accuracy, and cost of a new electronic disease surveillance system at the local health department level. We describe practices associated with lower cost and better surveillance timeliness and accuracy. Methods. Interviews conducted May through August 2010 with local health department (LHD) staff at a simple random sample of 30 of 100 North Carolina counties provided information on surveillance practices and costs; we used surveillance system data to calculate timeliness and accuracy. We identified LHDs with best timeliness and accuracy and used these categories to compare surveillance practices and costs. Results. Local health departments in the top tertiles for surveillance timeliness and accuracy had a lower cost per case reported than LHDs with lower timeliness and accuracy ($71 and $124 per case reported, respectively; P = .03). Best surveillance practices fell into 2 domains: efficient use of the electronic surveillance system and use of surveillance data for local evaluation and program management. Conclusions. Timely and accurate surveillance can be achieved in the setting of restricted funding experienced by many LHDs. Adopting best surveillance practices may improve both efficiency and public health outcomes. PMID:24134385

  15. Is Taurolidine-citrate an effective and cost-effective hemodialysis catheter lock solution? A systematic review and cost- effectiveness analysis.

    PubMed

    Kavosi, Zahra; Sarikhani Khorrami, Maryam; Keshavarz, Khosro; Jafari, Abdosaleh; Hashemi Meshkini, Amir; Safaei, Hamid Reza; Nikfar, Shekoufeh

    2016-01-01

    Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other common alternatives in Iran. To evaluate the efficacy of taurolidine-citrate, a systematic review was conducted by searching electronic databases. The outcomes of interest for cost-effectiveness analysis were as follows: "Catheter-related bacteremia episodes"; "catheter-related bacteremia-free survival"; "catheter thrombosis rate" for efficacy evaluation and "reduction of catheter-related infection". For evidence synthesis, a meta-analysis was conducted on the extracted efficacy data. To evaluate the cost of treatments, direct medical costs were included, and the incremental cost-effectiveness ratio was calculated for each comparison. The payers' (patients and insurance companies) perspectives were used for cost analysis. After carrying out the systematic process, three articles were included in the analysis. Considering 95% confidence interval, the relative difference was -0.16 (-0.25 to -0.07) for catheterrelated bacteremia episode, indicating that the rate of catheter-related infections in hemodialysis patients who used taurolidine-citrate was 16% less than in those hemodialysis patients who received heparin. Considering 95% confidence interval, the relative difference was 0.13 (-0.06 0.32) for catheter thrombosis, showing that the rate of catheter-related thrombosis in hemodialysis patients who used taurolidine-citrate was 13% more than in hemodialysis patients who received heparin. The results of this analysis indicated that taurolidine-citrate, compared to heparin, was more effective in preventing catheter-related infection; therefore, it could be considered as a superior strategy. Nevertheless, compared to heparin-gentamicin combination, taurolidine-citrate is an inferior strategy because of its higher cost and lower infection prevention. Compared to heparin, taurolidine-citrate is a superior option, but it is an inferior strategy compared to heparin-gentamicin combination. The clinical evidences on taurolidine-citrate, heparin and gentamicin/heparin are not sufficient for making confident decisions.

  16. The cost-effectiveness of supportive periodontal care for patients with chronic periodontitis.

    PubMed

    Gaunt, Francesca; Devine, Maria; Pennington, Mark; Vernazza, Chris; Gwynnett, Erika; Steen, Nick; Heasman, Peter

    2008-09-01

    To systematically evaluate the evidence for effectiveness of supportive periodontal care (SPC) provided in specialist care and general practice for patients with chronic periodontitis; to construct a model for the cost effectiveness of SPC. Electronic database searches of MEDLINE, EMBASE and SCOPUS were performed with hand searching of relevant journals and Workshops of Periodontology. SPC for patients with chronic periodontitis, at least 12 months follow-up and clinical attachment level as a primary outcome. Three articles addressed the question (Nyman et al. 1975, Axelsson & Lindhe 1981, Cortellini et al. 1994): Deltas CAL for patients undergoing "specialist" SPC were 0.1 mm (2 years), 0.2 mm (6 years) and -0.01 mm (3 years) respectively. In generalist care the Deltas CAL during SPC were -2.2, -1.8 and -2.8 mm. Differences between specialist and generalist SPC were an extra 20.59 tooth years and 3.95 mm attachment loss for generalist SPC. Incremental cost-effectiveness ratios were an extra 288 euros for one tooth year or an extra 1503 euros/1 mm reduction in loss of attachment for SPC delivered in specialist care. SPC delivered in specialist as compared with general practice will result in greater stability of clinical attachment but this will be achieved at relatively greater cost.

  17. The total cost of EHR ownership.

    PubMed

    Eastaugh, Steven R

    2013-02-01

    Consider total cost of ownership, not just initial cost of acquisition and annual maintenance, when reviewing electronic health record (EHR) system bids. Support costs--a key part of total cost of ownership--include FTEs dedicated to the system. The long-term costs of an EHR system can vary dramatically (up to 200 percent) depending on which system is selected.

  18. Solar power satellite system definition study. Volume 1: Executive summary, phase 3

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Results of a three phase study of the Solar Power Satellite System are summarized. Various options and alternate systems were considered and the following conclusions were reached: antenna mounted solid state transmitters are potentially as cost effective as the klystron approach, althrough limited to 2500 megawatts net output; the free electron laser and optical diode laser appear most promising for laser power transmission; ground antenna siting need not be restricted to below 35 degrees of latitude; and nonrecurring cost reductions attainable by using a smaller Heavy Lift Launch Vehicle are highly attractive.

  19. 2D scanning Rotman lens structure for smart collision avoidance sensors

    NASA Astrophysics Data System (ADS)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2004-03-01

    Although electronically scanned antenna arrays can provide effective mm-wave search radar sensors, their high cost and complexity are leading to the consideration of alternative beam-forming arrangements. Rotman lenses offer a compact, rugged, reliable, alternative solution. This paper considers the design of a microstrip based Rotman lens for high-resolution, frequency-controlled scanning applications. Its implementation in microstrip is attractive because this technology is low-cost, conformal, and lightweight. A sensor designed for operation at 77 GHz is presented and an ~80° azimuthal scan over a 30 GHz bandwidth is demonstrated.

  20. Impact: a low cost, reconfigurable, digital beamforming common module building block for next generation phased arrays

    NASA Astrophysics Data System (ADS)

    Paulsen, Lee; Hoffmann, Ted; Fulton, Caleb; Yeary, Mark; Saunders, Austin; Thompson, Dan; Chen, Bill; Guo, Alex; Murmann, Boris

    2015-05-01

    Phased array systems offer numerous advantages to the modern warfighter in multiple application spaces, including Radar, Electronic Warfare, Signals Intelligence, and Communications. However, a lack of commonality in the underlying technology base for DoD Phased Arrays has led to static systems with long development cycles, slow technology refreshes in response to emerging threats, and expensive, application-specific sub-components. The IMPACT module (Integrated Multi-use Phased Array Common Tile) is a multi-channel, reconfigurable, cost-effective beamformer that provides a common building block for multiple, disparate array applications.

  1. EB welding of launch vehicles

    NASA Astrophysics Data System (ADS)

    Szabo, Attila

    While large structural components can be electron beam (EB) welded, equipment and operating costs increase with the requisite vacuum chamber's size. Attention is presently given to cost-effective ways of EB welding launch-vehicle assemblies without compromise of weld quality in such alloys as 2219, 2090, Weldalite, and HP9-4-30/20. Weld strengths at both room and cryogenic temperatures that were 50 percent higher than those obtainable for such materials with arc welding have been demonstrated. Fracture toughnesses were also 40-50 percent higher than arc-welded values. Attention is given to EB joint fit-up allowables for 2219-T87 Al alloy.

  2. Systems Integration Fact Sheet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2016-06-01

    This fact sheet is an overview of the Systems Integration subprogram at the U.S. Department of Energy SunShot Initiative. The Systems Integration subprogram enables the widespread deployment of safe, reliable, and cost-effective solar energy technologies by addressing the associated technical and non-technical challenges. These include timely and cost-effective interconnection procedures, optimal system planning, accurate prediction of solar resources, monitoring and control of solar power, maintaining grid reliability and stability, and many more. To address the challenges associated with interconnecting and integrating hundreds of gigawatts of solar power onto the electricity grid, the Systems Integration program funds research, development, and demonstrationmore » projects in four broad, interrelated focus areas: grid performance and reliability, dispatchability, power electronics, and communications.« less

  3. Materials, Processes, and Facile Manufacturing for Bioresorbable Electronics: A Review.

    PubMed

    Yu, Xiaowei; Shou, Wan; Mahajan, Bikram K; Huang, Xian; Pan, Heng

    2018-05-07

    Bioresorbable electronics refer to a new class of advanced electronics that can completely dissolve or disintegrate with environmentally and biologically benign byproducts in water and biofluids. They have provided a solution to the growing electronic waste problem with applications in temporary usage of electronics such as implantable devices and environmental sensors. Bioresorbable materials such as biodegradable polymers, dissolvable conductors, semiconductors, and dielectrics are extensively studied, enabling massive progress of bioresorbable electronic devices. Processing and patterning of these materials are predominantly relying on vacuum-based fabrication methods so far. However, for the purpose of commercialization, nonvacuum, low-cost, and facile manufacturing/printing approaches are the need of the hour. Bioresorbable electronic materials are generally more chemically reactive than conventional electronic materials, which require particular attention in developing the low-cost manufacturing processes in ambient environment. This review focuses on material reactivity, ink availability, printability, and process compatibility for facile manufacturing of bioresorbable electronics. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. An Adaptable Power System with Software Control Algorithm

    NASA Technical Reports Server (NTRS)

    Castell, Karen; Bay, Mike; Hernandez-Pellerano, Amri; Ha, Kong

    1998-01-01

    A low cost, flexible and modular spacecraft power system design was developed in response to a call for an architecture that could accommodate multiple missions in the small to medium load range. Three upcoming satellites will use this design, with one launch date in 1999 and two in the year 2000. The design consists of modular hardware that can be scaled up or down, without additional cost, to suit missions in the 200 to 600 Watt orbital average load range. The design will be applied to satellite orbits that are circular, polar elliptical and a libration point orbit. Mission unique adaptations are accomplished in software and firmware. In designing this advanced, adaptable power system, the major goals were reduction in weight volume and cost. This power system design represents reductions in weight of 78 percent, volume of 86 percent and cost of 65 percent from previous comparable systems. The efforts to miniaturize the electronics without sacrificing performance has created streamlined power electronics with control functions residing in the system microprocessor. The power system design can handle any battery size up to 50 Amp-hour and any battery technology. The three current implementations will use both nickel cadmium and nickel hydrogen batteries ranging in size from 21 to 50 Amp-hours. Multiple batteries can be used by adding another battery module. Any solar cell technology can be used and various array layouts can be incorporated with no change in Power System Electronics (PSE) hardware. Other features of the design are the standardized interfaces between cards and subsystems and immunity to radiation effects up to 30 krad Total Ionizing Dose (TID) and 35 Mev/cm(exp 2)-kg for Single Event Effects (SEE). The control algorithm for the power system resides in a radiation-hardened microprocessor. A table driven software design allows for flexibility in mission specific requirements. By storing critical power system constants in memory, modifying the system code for other programs is simple. These constants can be altered also by ground command, or in response to an anomolous event. All critical power system functions have backup hardware functions to prevent a software or computer glitch from propagating. A number of battery charge control schemes can be implemented by selecting the proper control terms in the code. The architecture allows the design engineer to tune the system response to various system components and anticipated load profiles without costly alterations. A design trade was made with the size, weight and power dissipation of the electronics versus the performance of the power bus to load variations. Linear, fine control is maintained with a streamlined electronics design. This paper describes the hardware design as well as the software control algorithm. The challenges of closing the system control loop digitally is discussed. Control loop margin and power system performance is presented. Lab measurements are shown and compared to the system response of a hardware model running actual flight software.

  5. COST EFFECTIVE REGULATORY APPROACHES TO ENHANCE DOMESTIC OIL & GAS PRODUCTION AND ENSURE THE PROTECTION OF THE ENVIRONMENT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ben Grunewald; Paul Jehn; Tom Gillespie

    The Environmental Information Management Suite/Risk Based Data Management System (EIMS/RBDMS) and Cost Effective Regulatory Approach (CERA) programs continue to be successful. All oil and gas state regulatory programs participate in these efforts. Significant accomplishments include: streamline regulatory approaches, enhancing environmental protection, and making oil and gas data available via the Internet. Oil and gas companies worldwide now have access to data on state web sites. This reduces the cost of exploration and enables companies to develop properties in areas that would have been cost prohibited for exploration. Early in project, GWPC and State Oil and Gas agencies developed the EIMSmore » and CERA strategic plan to prioritize long term development and implementation. The planning process identifies electronic commerce and coal bed methane as high priorities. The group has involved strategic partners in industry and government to develop a common data exchange process. Technical assistance to Alaska continues to improve their program management capabilities. New initiatives in Alaska include the development of an electronic permit tracking system. This system allows managers to expedite the permitting process. Nationwide, the RBDMS system is largely completed with 22 states and one Indian Nation now using this nationally accepted data management system. Additional remaining tasks include routine maintenance and the installation of the program upon request for the remaining oil and gas states. The GWPC in working with the BLM and MMS to develop an XML schema to facilitate electronic permitting and reporting (Appendix A, B, and C). This is a significant effort and, in years to come, will increase access to federal lands by reducing regulatory barriers. The new initiatives are coal bed methane and e-commerce. The e-commerce program will provide industry and BLM/MMS access to the millions of data points housed in the RBDMS system. E-commerce will streamline regulatory approaches and allow small operators to produce energy from areas that have become sub-economic for the major producers. The GWPC is working with states to develop a coal bed methane program, which will both manage the data and develop a public education program on the benefits of produced water. The CERA program benefits all oil and gas states by reducing the cost of regulatory compliance, increasing environmental protection, and providing industry and regulatory agencies a discussion forum. Activities included many small and large group forum settings for discussions of technical and policy issues as well as the ongoing State Class II UIC peer review effort. The accomplishments detailed in this report will be the basis for the next initiative which is RBDMS On-Line. RBDMS On-Line will combine data mining, electronic permitting and electronic reporting with .net technology. Industry, BLM, GWPC and all Oil and Gas states are partnering this effort.« less

  6. Advanced risk assessment of the effects of graphite fibers on electronic and electric equipment

    NASA Technical Reports Server (NTRS)

    Pocinki, L.; Cornell, M.; Kaplan, L.

    1980-01-01

    An assessment of the risk associated with accidents involving aircraft with carbon fiber composite structural components is examined. The individual fiber segments cause electrical and electronic equipment to fail under certain operating conditions. A Monte Carlo simulation model was used to computer the risk. Aircraft accidents with fire, release of carbon fiber material, entrainment of carbon fibers in a smoke plume transport of fibers downwind, transfer of some fibers/into the the interior of buildings, failures of electrical and electronic equipment, and economic impact of failures are discussed. Risk profiles were prepared for individual airports and the Nation. The vulnerability of electrical transmission equipment to carbon fiber incursion and aircraft accident total costs is investigated.

  7. Compact self-powered synchronous energy extraction circuit design with enhanced performance

    NASA Astrophysics Data System (ADS)

    Liu, Weiqun; Zhao, Caiyou; Badel, Adrien; Formosa, Fabien; Zhu, Qiao; Hu, Guangdi

    2018-04-01

    Synchronous switching circuit is viewed as an effective solution of enhancing the generator’s performance and providing better adaptability for load variations. A critical issue for these synchronous switching circuits is the self-powered realization. In contrast with other methods, the electronic breaker possesses the advantage of simplicity and reliability. However, beside the energy consumption of the electronic breakers, the parasitic capacitance decreases the available piezoelectric voltage. In this technical note, a new compact design of the self-powered switching circuit using electronic breaker is proposed. The envelope diodes are excluded and only a single envelope capacitor is used. The parasitic capacitance is reduced to half with boosted performance while the components are reduced with cost saved.

  8. A Cost-Effectiveness Analysis of Blended Versus Face-to-Face Delivery of Evidence-Based Medicine to Medical Students

    PubMed Central

    Nicklen, Peter; Rivers, George; Foo, Jonathan; Ooi, Ying Ying; Reeves, Scott; Walsh, Kieran; Ilic, Dragan

    2015-01-01

    Background Blended learning describes a combination of teaching methods, often utilizing digital technologies. Research suggests that learner outcomes can be improved through some blended learning formats. However, the cost-effectiveness of delivering blended learning is unclear. Objective This study aimed to determine the cost-effectiveness of a face-to-face learning and blended learning approach for evidence-based medicine training within a medical program. Methods The economic evaluation was conducted as part of a randomized controlled trial (RCT) comparing the evidence-based medicine (EBM) competency of medical students who participated in two different modes of education delivery. In the traditional face-to-face method, students received ten 2-hour classes. In the blended learning approach, students received the same total face-to-face hours but with different activities and additional online and mobile learning. Online activities utilized YouTube and a library guide indexing electronic databases, guides, and books. Mobile learning involved self-directed interactions with patients in their regular clinical placements. The attribution and differentiation of costs between the interventions within the RCT was measured in conjunction with measured outcomes of effectiveness. An incremental cost-effectiveness ratio was calculated comparing the ongoing operation costs of each method with the level of EBM proficiency achieved. Present value analysis was used to calculate the break-even point considering the transition cost and the difference in ongoing operation cost. Results The incremental cost-effectiveness ratio indicated that it costs 24% less to educate a student to the same level of EBM competency via the blended learning approach used in the study, when excluding transition costs. The sunk cost of approximately AUD $40,000 to transition to the blended model exceeds any savings from using the approach within the first year of its implementation; however, a break-even point is achieved within its third iteration and relative savings in the subsequent years. The sensitivity analysis indicates that approaches with higher transition costs, or staffing requirements over that of a traditional method, are likely to result in negative value propositions. Conclusions Under the study conditions, a blended learning approach was more cost-effective to operate and resulted in improved value for the institution after the third year iteration, when compared to the traditional face-to-face model. The wider applicability of the findings are dependent on the type of blended learning utilized, staffing expertise, and educational context. PMID:26197801

  9. Effectiveness of mobile electronic devices in weight loss among overweight and obese populations: a systematic review and meta-analysis.

    PubMed

    Khokhar, Bushra; Jones, Jessica; Ronksley, Paul E; Armstrong, Marni J; Caird, Jeff; Rabi, Doreen

    2014-01-01

    Mobile electronic devices, such as mobile phones and PDAs, have emerged as potentially useful tools in the facilitation and maintenance of weight loss. While RCTs have demonstrated a positive impact of mobile interventions, the extent to which mobile electronic devices are more effective than usual care methods is still being debated. Electronic databases were systematically searched for RCTs evaluating the effectiveness of mobile electronic device interventions among overweight and obese adults. Weighted mean difference for change in body weight was the primary outcome. The search strategy yielded 559 citations and of the 108 potentially relevant studies, six met the criteria. A total of 632 participants were included in the six studies reporting a mean change in body weight. Using a random-effects model, the WMD for the effect of using mobile electronic devices on reduction in body weight was -1.09 kg (95% CI -2.12, -0.05). When stratified by the type of mobile electronic device used, it suggests that interventions using mobile phones were effective at achieving weight loss, WMD = -1.78 kg (95% CI -2.92, -0.63). This systematic review and meta-analysis suggests that mobile electronic devices have the potential to facilitate weight loss in overweight and obese populations, but further work is needed to understand if these interventions have sustained benefit and how we can make these mHealth tools most effective on a large scale. As the field of healthcare increasingly utilizes novel mobile technologies, the focus must not be on any one specific device but on the best possible use of these tools to measure and understand behavior. As mobile electronic devices continue to increase in popularity and the associated technology continues to advance, the potential for the use of mobile devices in global healthcare is enormous. More RCTs with larger sample sizes need to be conducted to look at the cost-effectiveness, technical and financial feasibility of adapting such mHealth interventions in a real clinical setting.

  10. Design and implementation of population-based specialty care programs.

    PubMed

    Botts, Sheila R; Gee, Michael T; Chang, Christopher C; Young, Iris; Saito, Logan; Lyman, Alfred E

    2017-09-15

    The development, implementation, and scaling of 3 population-based specialty care programs in a large integrated healthcare system are reviewed, and the role of clinical pharmacy services in ensuring safe, effective, and affordable care is highlighted. The Kaiser Permanente (KP) integrated healthcare delivery model allows for rapid development and expansion of innovative population management programs involving pharmacy services. Clinical pharmacists have assumed integral roles in improving the safety and effectiveness of high-complexity, high-cost care for specialty populations. These roles require an appropriate practice scope and are supported by an advanced electronic health record with disease registries and electronic surveillance tools for care-gap identification. The 3 specialty population programs described were implemented to address variation or unrecognized gaps in care for at-risk specialty populations. The Home Phototherapy Program has leveraged internal partnerships with clinical pharmacists to improve access to cost-effective nonpharmacologic interventions for psoriasis and other skin disorders. The Multiple Sclerosis Care Program has incorporated clinical pharmacists into neurology care in order to apply clinical guidelines in a systematic manner. The KP SureNet program has used clinical pharmacists and data analytics to identify opportunities to prevent drug-related adverse outcomes and ensure timely follow-up. Specialty care programs improve quality, cost outcomes, and the patient experience by appropriating resources to provide systematic and targeted care to high-risk patients. KP leverages an integration of people, processes, and technology to develop and scale population-based specialty care. Copyright © 2017 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  11. A cost-effective and simple electronic solution to communication with patients with tracheostomy in a burns and intensive care setting.

    PubMed

    Javed, Muhammad; Dingley, John; Dickson, William; Shokrollahi, Kayvan

    2014-02-01

    Ventilated patients in ITU (intensive treatment unit) tend to be challenging to communicate with, especially patients who are being weaned. These patients usually have tracheostomy in situ and use means such as writing or letter boards to communicate. The situation becomes complex in patient groups that have burn injuries with bulky dressings and restricted upper limb function. We demonstrate a low cost, easy to use, potentially disposable system that can display words on any television screen via patient input device for such patient groups. The system consists of input device incorporated with Arduino microcontroller (an open-source electronics prototyping platform based on easy-to-use hardware and software intended for creating interactive environments) and 4 generously oversized control buttons. These are used to control the cursor movements (up, down, left, right) while a fifth has a "select" function. These are large enough to be pressed by an entire bandaged hand using gross upper limb movements only. A standard television is used to display menu containing the 26 letters of the alphabet and a flashing cursor. The patient selects the required letters/icon by moving the cursor and the words so created are displayed along the lower part of the screen for the carers to read. It is envisaged that anyone with basic craft skills should be able to construct this device. This device is a self-contained, cost-effective, simple, and open-source system that can be used effectively to bridge the communication gap with significant potential for patient care globally.

  12. Evaluation of an Android-based mHealth system for population surveillance in developing countries

    PubMed Central

    Mbugua, Samuel; Amadi, David; Chepnǵeno, Viola; Saleem, Jason J; Anokwa, Yaw; Hartung, Carl; Borriello, Gaetano; Mamlin, Burke W; Ndege, Samson K; Were, Martin C

    2012-01-01

    Objective In parts of the developing world traditionally modeled healthcare systems do not adequately meet the needs of the populace. This can be due to imbalances in both supply and demand—there may be a lack of sufficient healthcare and the population most at need may be unable or unwilling to take advantage of it. Home-based care has emerged as a possible mechanism to bring healthcare to the populace in a cost-effective, useful manner. This study describes the development, implementation, and evaluation of a mobile device-based system to support such services. Materials and Methods Mobile phones were utilized and a structured survey was implemented to be administered by community health workers using Open Data Kit. This system was used to support screening efforts for a population of two million persons in western Kenya. Results Users of the system felt it was easy to use and facilitated their work. The system was also more cost effective than pen and paper alternatives. Discussion This implementation is one of the largest applications of a system utilizing handheld devices for performing clinical care during home visits in a resource-constrained environment. Because the data were immediately available electronically, initial reports could be performed and important trends in data could thus be detected. This allowed adjustments to the programme to be made sooner than might have otherwise been possible. Conclusion A viable, cost-effective solution at scale has been developed and implemented for collecting electronic data during household visits in a resource-constrained setting. PMID:22366295

  13. Printed organo-functionalized graphene for biosensing applications.

    PubMed

    Wisitsoraat, A; Mensing, J Ph; Karuwan, C; Sriprachuabwong, C; Jaruwongrungsee, K; Phokharatkul, D; Daniels, T M; Liewhiran, C; Tuantranont, A

    2017-01-15

    Graphene is a highly promising material for biosensors due to its excellent physical and chemical properties which facilitate electron transfer between the active locales of enzymes or other biomaterials and a transducer surface. Printing technology has recently emerged as a low-cost and practical method for fabrication of flexible and disposable electronics devices. The combination of these technologies is promising for the production and commercialization of low cost sensors. In this review, recent developments in organo-functionalized graphene and printed biosensor technologies are comprehensively covered. Firstly, various methods for printing graphene-based fluids on different substrates are discussed. Secondly, different graphene-based ink materials and preparation methods are described. Lastly, biosensing performances of printed or printable graphene-based electrochemical and field effect transistor sensors for some important analytes are elaborated. The reported printed graphene based sensors exhibit promising properties with good reliability suitable for commercial applications. Among most reports, only a few printed graphene-based biosensors including screen-printed oxidase-functionalized graphene biosensor have been demonstrated. The technology is still at early stage but rapidly growing and will earn great attention in the near future due to increasing demand of low-cost and disposable biosensors. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. RECENT DEVELOPMENTS IN HYDROLOGIC INSTRUMENTATION.

    USGS Publications Warehouse

    Latkovich, Vito J.

    1985-01-01

    The availability of space-age materials and implementation of state-of-the-art electronics is making possible the recent developments of hydrologic instrumentation. Material developments include: Synthetic-fiber sounding and tag lines; fiberglass wading rod; polymer (plastic) sheaves, pulleys and sampler components; and polymer (plastic) bucket wheels for current meters. These materials are very cost effective and efficient. Electromechanical and electronic developments and applications include: adaptable data acquisition system; downhole sampler for hazardous substances; current-meter digitizer; hydraulic power/drive system for discharge measurements and water-quality sampling; non-contact water-level sensors; minimum data recorder; acoustic velocity meters, and automated current meter discharge-measurement system.

  15. Fabrication of eco-friendly PNP transistor using RF magnetron sputtering

    NASA Astrophysics Data System (ADS)

    Kumar, B. Santhosh; Harinee, N.; Purvaja, K.; Shanker, N. Praveen; Manikandan, M.; Aparnadevi, N.; Mukilraj, T.; Venkateswaran, C.

    2018-05-01

    An effort has been made to fabricate a thin film transistor using eco-friendly oxide semiconductor materials. Oxide semiconductor materials are cost - effective, thermally and chemically stable with high electron/hole mobility. Copper (II) oxide is a p-type semiconductor and zinc oxide is an n-type semiconductor. A pnp thin film transistor was fabricated using RF magnetron sputtering. The films deposited have been subjected to structural characterization using AFM. I-V characterization of the fabricated device, Ag/CuO/ZnO/CuO/Ag, confirms transistor behaviour. The mechanism of electron/hole transport of the device is discussed below.

  16. US Army Research Laboratory power sources R and D programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christopher, H.A.; Gilman, S.; Hamlen, R.P.

    1993-05-01

    The development and application of new electronic technologies over the recent past has resulted in a major evolution of new electronic battlefield equipment. The need for lighter-weight and more cost effective power sources with higher power/energy density capability is critical to the successful development and deployment of these new, high performance battlefield devices. The current status and thrust of the Army Research Laboratory's (ARL's) battery and fuel cell R and D programs that support these new and emerging applications will be reviewed. Major technical barriers will be identified along with the corresponding proposed approaches to solving these anticipated problems.

  17. E-Nursing: electronic nursing resources on your desktop.

    PubMed

    Kendall, Sandra; Massaralla, Susan; Hynes-Gay, Patricia; Vincent, Leslie

    2003-01-01

    E-Nursing represents an innovative approach to nursing education that has the potential to support professional practice throughout the institution. This paper details the benefits, design and promotion of an electronic nursing resource collection. How to divide responsibility, cost and expertise in such a project is also discussed. Preliminary usage statistics validate E-Nursing as a point-of-care education tool for nurses at Mount Sinai Hospital. A planned approach to implementation has been an effective means of introducing E-Nursing in an institution that previously relied on traditional hard-copy resources housed in the hospital's library.

  18. Ultrafast electron diffraction pattern simulations using GPU technology. Applications to lattice vibrations.

    PubMed

    Eggeman, A S; London, A; Midgley, P A

    2013-11-01

    Graphical processing units (GPUs) offer a cost-effective and powerful means to enhance the processing power of computers. Here we show how GPUs can greatly increase the speed of electron diffraction pattern simulations by the implementation of a novel method to generate the phase grating used in multislice calculations. The increase in speed is especially apparent when using large supercell arrays and we illustrate the benefits of fast encoding the transmission function representing the atomic potentials through the simulation of thermal diffuse scattering in silicon brought about by specific vibrational modes. © 2013 Elsevier B.V. All rights reserved.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, T.; Hu, M.; Guo, Q.

    Here we report a study of printing of electronics using an office use laser printer. The proposed method eliminates those critical disadvantages of solvent-based printing techniques by taking the advantages of electroless deposition and laser printing. The synthesized toner acts as a catalyst for the electroless copper deposition as well as an adhesion-promoting buffer layer between the substrate and deposited copper. The easy metallization of printed patterns and strong metal-substrate adhesion make it an especially effective method for massive production of flexible printed circuits. The proposed process is a high throughput, low cost, efficient, and environmentally benign method for flexiblemore » electronics manufacturing.« less

  20. Cost-effectiveness of an electronic medication ordering system (CPOE/CDSS) in hospitalized patients.

    PubMed

    Vermeulen, K M; van Doormaal, J E; Zaal, R J; Mol, P G M; Lenderink, A W; Haaijer-Ruskamp, F M; Kosterink, J G W; van den Bemt, P M L A

    2014-08-01

    Prescribing medication is an important aspect of almost all in-hospital treatment regimes. Besides their obviously beneficial effects, medicines can also cause adverse drug events (ADE), which increase morbidity, mortality and health care costs. Partially, these ADEs arise from medication errors, e.g. at the prescribing stage. ADEs caused by medication errors are preventable ADEs. Until now, medication ordering was primarily a paper-based process and consequently, it was error prone. Computerized Physician Order Entry, combined with basic Clinical Decision Support System (CPOE/CDSS) is considered to enhance patient safety. Limited information is available on the balance between the health gains and the costs that need to be invested in order to achieve these positive effects. Aim of this study was to study the balance between the effects and costs of CPOE/CDSS compared to the traditional paper-based medication ordering. The economic evaluation was performed alongside a clinical study (interrupted time series design) on the effectiveness of CPOE/CDSS, including a cost minimization and a cost-effectiveness analysis. Data collection took place between 2005 and 2008. Analyses were performed from a hospital perspective. The study was performed in a general teaching hospital and a University Medical Centre on general internal medicine, gastroenterology and geriatric wards. Computerized Physician Order Entry, combined with basic Clinical Decision Support System (CPOE/CDSS) was compared to a traditional paper based system. All costs of both medication ordering systems are based on resources used and time invested. Prices were expressed in Euros (price level 2009). Effectiveness outcomes were medication errors and preventable adverse drug events. During the paper-based prescribing period 592 patients were included, and during the CPOE/CDSS period 603. Total costs of the paper-based system and CPOE/CDSS amounted to €12.37 and €14.91 per patient/day respectively. The Incremental Cost-Effectiveness Ratio (ICER) for medication errors was 3.54 and for preventable adverse drug events 322.70, indicating the extra amount (€) that has to be invested in order to prevent one medication error or one pADE. CPOE with basic CDSS contributes to a decreased risk of preventable harm. Overall, the extra costs of CPOE/CDSS needed to prevent one ME or one pADE seem to be acceptable. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Standard Hardware Acquisition and Reliability Program's (SHARP's) efforts in incorporating fiber optic interconnects into standard electronic module (SEM) connectors

    NASA Astrophysics Data System (ADS)

    Riggs, William R.

    1994-05-01

    SHARP is a Navy wide logistics technology development effort aimed at reducing the acquisition costs, support costs, and risks of military electronic weapon systems while increasing the performance capability, reliability, maintainability, and readiness of these systems. Lower life cycle costs for electronic hardware are achieved through technology transition, standardization, and reliability enhancement to improve system affordability and availability as well as enhancing fleet modernization. Advanced technology is transferred into the fleet through hardware specifications for weapon system building blocks of standard electronic modules, standard power systems, and standard electronic systems. The product lines are all defined with respect to their size, weight, I/O, environmental performance, and operational performance. This method of defining the standard is very conducive to inserting new technologies into systems using the standard hardware. This is the approach taken thus far in inserting photonic technologies into SHARP hardware. All of the efforts have been related to module packaging; i.e. interconnects, component packaging, and module developments. Fiber optic interconnects are discussed in this paper.

  2. HIV prevention cost-effectiveness: a systematic review

    PubMed Central

    2009-01-01

    Background After more than 25 years, public health programs have not been able to sufficiently reduce the number of new HIV infections. Over 7,000 people become infected with HIV every day. Lack of convincing evidence of cost-effectiveness (CE) may be one of the reasons why implementation of effective programs is not occurring at sufficient scale. This paper identifies, summarizes and critiques the CE literature related to HIV-prevention interventions in low- and middle-income countries during 2005-2008. Methods Systematic identification of publications was conducted through several methods: electronic databases, internet search of international organizations and major funding/implementing agencies, and journal browsing. Inclusion criteria included: HIV prevention intervention, year for publication (2005-2008), setting (low- and middle-income countries), and CE estimation (empirical or modeling) using outcomes in terms of cost per HIV infection averted and/or cost per disability-adjusted life year (DALY) or quality-adjusted life year (QALY). Results We found 21 distinct studies analyzing the CE of HIV-prevention interventions published in the past four years (2005-2008). Seventeen CE studies analyzed biomedical interventions; only a few dealt with behavioral and environmental/structural interventions. Sixteen studies focused on sub-Saharan Africa, and only a handful on Asia, Latin America and Eastern Europe. Many HIV-prevention interventions are very cost effective in absolute terms (using costs per DALY averted), and also in country-specific relative terms (in cost per DALY measured as percentage of GDP per capita). Conclusion There are several types of interventions for which CE studies are still not available or insufficient, including surveillance, abstinence, school-based education, universal precautions, prevention for positives and most structural interventions. The sparse CE evidence available is not easily comparable; thus, not very useful for decision making. More than 25 years into the AIDS epidemic and billions of dollars of spending later, there is still much work to be done both on costs and effectiveness to adequately inform HIV prevention planning. PMID:19922689

  3. The Seamless Transfer-of-Care Protocol: a randomized controlled trial assessing the efficacy of an electronic transfer-of-care communication tool.

    PubMed

    Okoniewska, Barbara M; Santana, Maria J; Holroyd-Leduc, Jayna; Flemons, Ward; O'Beirne, Maeve; White, Deborah; Clement, Fiona; Forster, Alan; Ghali, William A

    2012-11-21

    The transition between acute care and community care represents a vulnerable period in health care delivery. The vulnerability of this period has been attributed to changes to patients' medication regimens during hospitalization, failure to reconcile discrepancies between admission and discharge and the burdening of patients/families to take over care responsibilities at discharge and to relay important information to the primary care physician. Electronic communication platforms can provide an immediate link between acute care and community care physicians (and other community providers), designed to ensure consistent information transfer. This study examines whether a transfer-of-care (TOC) communication tool is efficacious and cost-effective for reducing hospital readmission, adverse events and adverse drug events as well as reducing death. A randomized controlled trial conducted on the Medical Teaching Unit of a Canadian tertiary care centre will evaluate the efficacy and cost-effectiveness of a TOC communication tool. Medical in-patients admitted to the unit will be considered for this study. Data will be collected upon admission, and a total of 1400 patients will be randomized. The control group's acute care stay will be summarized using a traditional dictated summary, while the intervention group will have a summary generated using the TOC communication tool. The primary outcome will be a composite, at 3 months, of death or readmission to any Alberta acute-care hospital. Secondary outcomes will be the occurrence of post-discharge adverse events and adverse drug events at 1 month post discharge. Patients with adverse outcomes will have their cases reviewed by two Royal College certified internists or College-certified family physicians, blinded to patients' group assignments, to determine the type, severity, preventability and ameliorability of all detected adverse outcomes. An accompanying economic evaluation will assess the cost per life saved, cost per readmission avoided and cost per QALY gained with the TOC communication tool compared to traditional dictation summaries. This paper outlines the study protocol for a randomized controlled trial evaluating an electronic transfer-of-care communication tool, with sufficient statistical power to assess the impact of the tool on the significant outcomes of post-discharge death or readmission. The study findings will inform health systems around the world on the potential benefits of such tools, and the value for money associated with their widespread implementation. ClinicalTrials.gov NCT01402609.

  4. Together Achieving More: Primary Care Team Communication and Alcohol-Related Health Care Utilization and Costs

    PubMed Central

    Mundt, Marlon P.; Zakletskaia, Larissa I.; Shoham, David A.; Tuan, Wen-Jan; Carayon, Pascale

    2015-01-01

    Background Identifying and engaging excessive alcohol users in primary care may be an effective way to improve patient health outcomes, reduce alcohol-related acute care events, and lower costs. Little is known about what structures of primary care team communication are associated with alcohol-related patient outcomes. Methods Using a sociometric survey of primary care clinic communication, this study evaluated the relation between team communication networks and alcohol-related utilization of care and costs. Between May 2013 and December 2013, a total of 155 healthcare employees at 6 primary care clinics participated in a survey on team communication. Three-level hierarchical modeling evaluated the link between connectedness within the care team and the number of alcohol-related emergency department visits, hospital days, and associated medical care costs in the past 12 months for each team’s primary care patient panel. Results Teams (n=31) whose RNs displayed more strong (at least daily) face-to-face ties and strong (at least daily) electronic communication ties had 10% fewer alcohol-related hospital days (RR=0.90; 95% CI: 0.84, 0.97). Furthermore, in an average team size of 19, each additional team member with strong interaction ties across the whole team was associated with $1030 (95% CI: −$1819, −$241) lower alcohol-related patient health care costs per 1000 team patients in the past 12 months. Conversely, teams whose primary care practitioner had more strong face-to-face communication ties and more weak (weekly or several times a week) electronic communication ties had 12% more alcohol-related hospital days (RR=1.12; 95: CI: 1.03, 1.23) and $1428 (95% CI: $378, $2478) higher alcohol-related healthcare costs per 1000 patients in the past 12 months. The analyses controlled for patient age, gender, insurance, and co-morbidity diagnoses. Conclusions Excessive alcohol-using patients may fair better if cared for by teams whose face-to-face and electronic communication networks include more team members and whose communication to the PCP has been streamlined to fewer team members. PMID:26350957

  5. Together Achieving More: Primary Care Team Communication and Alcohol-Related Healthcare Utilization and Costs.

    PubMed

    Mundt, Marlon P; Zakletskaia, Larissa I; Shoham, David A; Tuan, Wen-Jan; Carayon, Pascale

    2015-10-01

    Identifying and engaging excessive alcohol users in primary care may be an effective way to improve patient health outcomes, reduce alcohol-related acute care events, and lower costs. Little is known about what structures of primary care team communication are associated with alcohol-related patient outcomes. Using a sociometric survey of primary care clinic communication, this study evaluated the relation between team communication networks and alcohol-related utilization of care and costs. Between May 2013 and December 2013, a total of 155 healthcare employees at 6 primary care clinics participated in a survey on team communication. Three-level hierarchical modeling evaluated the link between connectedness within the care team and the number of alcohol-related emergency department visits, hospital days, and associated medical care costs in the past 12 months for each team's primary care patient panel. Teams (n = 31) whose registered nurses displayed more strong (at least daily) face-to-face ties and strong (at least daily) electronic communication ties had 10% fewer alcohol-related hospital days (rate ratio [RR] = 0.90; 95% confidence interval [CI]: 0.84, 0.97). Furthermore, in an average team size of 19, each additional team member with strong interaction ties across the whole team was associated with $1,030 (95% CI: -$1,819, -$241) lower alcohol-related patient healthcare costs per 1,000 team patients in the past 12 months. Conversely, teams whose primary care practitioner (PCP) had more strong face-to-face communication ties and more weak (weekly or several times a week) electronic communication ties had 12% more alcohol-related hospital days (RR = 1.12; 95% CI: 1.03, 1.23) and $1,428 (95% CI: $378, $2,478) higher alcohol-related healthcare costs per 1,000 patients in the past 12 months. The analyses controlled for patient age, gender, insurance, and comorbidity diagnoses. Excessive alcohol-using patients may fair better if cared for by teams whose face-to-face and electronic communication networks include more team members and whose communication to the PCP has been streamlined to fewer team members. Copyright © 2015 by the Research Society on Alcoholism.

  6. A low-cost hierarchical nanostructured beta-titanium alloy with high strength

    PubMed Central

    Devaraj, Arun; Joshi, Vineet V.; Srivastava, Ankit; Manandhar, Sandeep; Moxson, Vladimir; Duz, Volodymyr A.; Lavender, Curt

    2016-01-01

    Lightweighting of automobiles by use of novel low-cost, high strength-to-weight ratio structural materials can reduce the consumption of fossil fuels and in turn CO2 emission. Working towards this goal we achieved high strength in a low cost β-titanium alloy, Ti–1Al–8V–5Fe (Ti185), by hierarchical nanostructure consisting of homogenous distribution of micron-scale and nanoscale α-phase precipitates within the β-phase matrix. The sequence of phase transformation leading to this hierarchical nanostructure is explored using electron microscopy and atom probe tomography. Our results suggest that the high number density of nanoscale α-phase precipitates in the β-phase matrix is due to ω assisted nucleation of α resulting in high tensile strength, greater than any current commercial titanium alloy. Thus hierarchical nanostructured Ti185 serves as an excellent candidate for replacing costlier titanium alloys and other structural alloys for cost-effective lightweighting applications. PMID:27034109

  7. Can real time location system technology (RTLS) provide useful estimates of time use by nursing personnel?

    PubMed

    Jones, Terry L; Schlegel, Cara

    2014-02-01

    Accurate, precise, unbiased, reliable, and cost-effective estimates of nursing time use are needed to insure safe staffing levels. Direct observation of nurses is costly, and conventional surrogate measures have limitations. To test the potential of electronic capture of time and motion through real time location systems (RTLS), a pilot study was conducted to assess efficacy (method agreement) of RTLS time use; inter-rater reliability of RTLS time-use estimates; and associated costs. Method agreement was high (mean absolute difference = 28 seconds); inter-rater reliability was high (ICC = 0.81-0.95; mean absolute difference = 2 seconds); and costs for obtaining RTLS time-use estimates on a single nursing unit exceeded $25,000. Continued experimentation with RTLS to obtain time-use estimates for nursing staff is warranted. © 2013 Wiley Periodicals, Inc.

  8. Investigating the performance of wavelet neural networks in ionospheric tomography using IGS data over Europe

    NASA Astrophysics Data System (ADS)

    Ghaffari Razin, Mir Reza; Voosoghi, Behzad

    2017-04-01

    Ionospheric tomography is a very cost-effective method which is used frequently to modeling of electron density distributions. In this paper, residual minimization training neural network (RMTNN) is used in voxel based ionospheric tomography. Due to the use of wavelet neural network (WNN) with back-propagation (BP) algorithm in RMTNN method, the new method is named modified RMTNN (MRMTNN). To train the WNN with BP algorithm, two cost functions is defined: total and vertical cost functions. Using minimization of cost functions, temporal and spatial ionospheric variations is studied. The GPS measurements of the international GNSS service (IGS) in the central Europe have been used for constructing a 3-D image of the electron density. Three days (2009.04.15, 2011.07.20 and 2013.06.01) with different solar activity index is used for the processing. To validate and better assess reliability of the proposed method, 4 ionosonde and 3 testing stations have been used. Also the results of MRMTNN has been compared to that of the RMTNN method, international reference ionosphere model 2012 (IRI-2012) and spherical cap harmonic (SCH) method as a local ionospheric model. The comparison of MRMTNN results with RMTNN, IRI-2012 and SCH models shows that the root mean square error (RMSE) and standard deviation of the proposed approach are superior to those of the traditional method.

  9. Economic outcomes of a dental electronic patient record.

    PubMed

    Langabeer, James R; Walji, Muhammad F; Taylor, David; Valenza, John A

    2008-10-01

    The implementation of an electronic patient record (EPR) in many sectors of health care has been suggested to have positive relationships with both quality of care and improved pedagogy, although evaluation of actual results has been somewhat disillusioning. Evidence-based dentistry clearly suggests the need for tools and systems to improve care, and an EPR is a critical tool that has been widely proposed in recent years. In dental schools, EPR systems are increasingly being adopted, despite obstacles such as high costs, time constraints necessary for process workflow change, and overall project complexity. The increasing movement towards cost-effectiveness analyses in health and medicine suggests that the EPR should generally cover expenses, or produce total benefits greater than its combined costs, to ensure that resources are being utilized efficiently. To test the underlying economics of an EPR, we utilized a pre-post research design with a probability-based economic simulation model to analyze changes in performance and costs in one dental school. Our findings suggest that the economics are positive, but only when student fees are treated as an incremental revenue source. In addition, other performance indicators appeared to have significant changes, although most were not comprehensively measured pre-implementation, making it difficult to truly understand the performance differential-such pre-measurement of expected benefits is a key lesson learned. This article also provides recommendations for dental clinics and universities that are about to embark on this endeavor.

  10. Nano-imprint lithography using poly (methyl methacrylate) (PMMA) and polystyrene (PS) polymers

    NASA Astrophysics Data System (ADS)

    Ting, Yung-Chiang; Shy, Shyi-Long

    2016-04-01

    Nano-imprinting lithography (NIL) technology, as one of the most promising fabrication technologies, has been demonstrated to be a powerful tool for large-area replication up to wafer-level, with features down to nanometer scale. The cost of resists used for NIL is important for wafer-level large-area replication. This study aims to develop capabilities in patterning larger area structure using thermal NIL. The commercial available Poly (Methyl Methacrylate) (PMMA) and Polystyrene (PS) polymers possess a variety of characteristics desirable for NIL, such as low material cost, low bulkvolumetric shrinkage, high spin coating thickness uniformity, high process stability, and acceptable dry-etch resistance. PMMA materials have been utilized for positive electron beam lithography for many years, offering high resolution capability and wide process latitude. In addition, it is preferable to have a negative resist like PMMA, which is a simple polymer with low cost and practically unlimited shelf life, and can be dissolved easily using commercial available Propylene glycol methyl ether acetate (PGMEA) safer solvent to give the preferred film thickness. PS is such a resist, as it undergoes crosslinking when exposed to deep UV light or an electron beam and can be used for NIL. The result is a cost effective patterning larger area structure using thermal nano-imprint lithography (NIL) by using commercial available PMMA and PS ploymers as NIL resists.

  11. Clinical applications of commercially available video recording and monitoring systems: inexpensive, high-quality video recording and monitoring systems for endoscopy and microsurgery.

    PubMed

    Tsunoda, Koichi; Tsunoda, Atsunobu; Ishimoto, ShinnIchi; Kimura, Satoko

    2006-01-01

    The exclusive charge-coupled device (CCD) camera system for the endoscope and electronic fiberscopes are in widespread use. However, both are usually stationary in an office or examination room, and a wheeled cart is needed for mobility. The total costs of the CCD camera system and electronic fiberscopy system are at least US Dollars 10,000 and US Dollars 30,000, respectively. Recently, the performance of audio and visual instruments has improved dramatically, with a concomitant reduction in their cost. Commercially available CCD video cameras with small monitors have become common. They provide excellent image quality and are much smaller and less expensive than previous models. The authors have developed adaptors for the popular mini-digital video (mini-DV) camera. The camera also provides video and acoustic output signals; therefore, the endoscopic images can be viewed on a large monitor simultaneously. The new system (a mini-DV video camera and an adaptor) costs only US Dollars 1,000. Therefore, the system is both cost-effective and useful for the outpatient clinic or casualty setting, or on house calls for the purpose of patient education. In the future, the authors plan to introduce the clinical application of a high-vision camera and an infrared camera as medical instruments for clinical and research situations.

  12. The cost-effectiveness of cash versus lottery incentives for a web-based, stated-preference community survey.

    PubMed

    Gajic, Aleksandra; Cameron, David; Hurley, Jeremiah

    2012-12-01

    We present the results of a randomized experiment to test the effectiveness and cost-effectiveness of response incentives for a stated-preference survey of a general community population. The survey was administered using a mixed-mode approach, in which community members were invited to participate using a traditional mailed letter using contact information for a representative sample of the community; but individuals completed the survey via the web, which exploited the advantages of electronic capture. Individuals were randomized to four incentive groups: (a) no incentive, (b) prepaid cash incentive ($2), (c) a low lottery (10 prizes of $25) and (d) a high lottery (2 prizes of $250). Letters of invitation were mailed to 3,000 individuals. In total, 405 individuals (14.4%) contacted the website and 277 (9.8%) provided complete responses. The prepaid cash incentive generated the highest contact and response rates (23.3 and 17.3%, respectively), and no incentive generated the lowest (9.1 and 5.7%, respectively). The high lottery, however, was the most cost-effective incentive for obtaining completed surveys: compared with no incentive, the incremental cost-effectiveness ratio (ICER) per completed survey for high lottery was $13.89; for prepaid cash, the ICER was $18.29. This finding suggests that the preferred response incentive for community-based, stated-preference surveys is a lottery with a small number of large prizes.

  13. Print versus Electronic: Editors' Insights on the Costs and Benefits of Online Journals.

    ERIC Educational Resources Information Center

    Angell, Brian D.; Smith, Gabie E.

    1998-01-01

    Responses from 26 of 40 editors of electronic journals indicates that 57% were motivated to go online by creative possibilities; only 42% had existing print-journal counterparts; 34.6% felt they reach a broader or different audience online; and 50% felt online journals were less costly and had the advantage of speed of production. (SK)

  14. Achieving strategic cost advantages by focusing on back-office efficiency.

    PubMed

    McDowell, Jim

    2010-06-01

    A study of more than 270 hospitals over a four-year period highlighted a number of investments that can reduce hospitals' costs and improve efficiency, including the following: E-procurement systems. Electronic exchange of invoices and payments (and electronic receipt of payments). Human resources IT systems that reduce the need for manual entry of data. Shared services deployment.

  15. Classical molecular dynamics simulation of electronically non-adiabatic processes.

    PubMed

    Miller, William H; Cotton, Stephen J

    2016-12-22

    Both classical and quantum mechanics (as well as hybrids thereof, i.e., semiclassical approaches) find widespread use in simulating dynamical processes in molecular systems. For large chemical systems, however, which involve potential energy surfaces (PES) of general/arbitrary form, it is usually the case that only classical molecular dynamics (MD) approaches are feasible, and their use is thus ubiquitous nowadays, at least for chemical processes involving dynamics on a single PES (i.e., within a single Born-Oppenheimer electronic state). This paper reviews recent developments in an approach which extends standard classical MD methods to the treatment of electronically non-adiabatic processes, i.e., those that involve transitions between different electronic states. The approach treats nuclear and electronic degrees of freedom (DOF) equivalently (i.e., by classical mechanics, thereby retaining the simplicity of standard MD), and provides "quantization" of the electronic states through a symmetrical quasi-classical (SQC) windowing model. The approach is seen to be capable of treating extreme regimes of strong and weak coupling between the electronic states, as well as accurately describing coherence effects in the electronic DOF (including the de-coherence of such effects caused by coupling to the nuclear DOF). A survey of recent applications is presented to illustrate the performance of the approach. Also described is a newly developed variation on the original SQC model (found universally superior to the original) and a general extension of the SQC model to obtain the full electronic density matrix (at no additional cost/complexity).

  16. Toward Environmentally Robust Organic Electronics: Approaches and Applications.

    PubMed

    Lee, Eun Kwang; Lee, Moo Yeol; Park, Cheol Hee; Lee, Hae Rang; Oh, Joon Hak

    2017-11-01

    Recent interest in flexible electronics has led to a paradigm shift in consumer electronics, and the emergent development of stretchable and wearable electronics is opening a new spectrum of ubiquitous applications for electronics. Organic electronic materials, such as π-conjugated small molecules and polymers, are highly suitable for use in low-cost wearable electronic devices, and their charge-carrier mobilities have now exceeded that of amorphous silicon. However, their commercialization is minimal, mainly because of weaknesses in terms of operational stability, long-term stability under ambient conditions, and chemical stability related to fabrication processes. Recently, however, many attempts have been made to overcome such instabilities of organic electronic materials. Here, an overview is provided of the strategies developed for environmentally robust organic electronics to overcome the detrimental effects of various critical factors such as oxygen, water, chemicals, heat, and light. Additionally, molecular design approaches to π-conjugated small molecules and polymers that are highly stable under ambient and harsh conditions are explored; such materials will circumvent the need for encapsulation and provide a greater degree of freedom using simple solution-based device-fabrication techniques. Applications that are made possible through these strategies are highlighted. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Development of a Simple Electron Transfer and Polarization Model and Its Application to Biological Systems.

    PubMed

    Diller, David J

    2017-01-10

    Here we present a new method for point charge calculation which we call Q ET (charges by electron transfer). The intent of this work is to develop a method that can be useful for studying charge transfer in large biological systems. It is based on the intuitive framework of the Q EQ method with the key difference being that the Q ET method tracks all pairwise electron transfers by augmenting the Q EQ pseudoenergy function with a distance dependent cost function for each electron transfer. This approach solves the key limitation of the Q EQ method which is its handling of formally charged groups. First, we parametrize the Q ET method by fitting to electrostatic potentials calculated using ab initio quantum mechanics on over 11,000 small molecules. On an external test set of over 2500 small molecules the Q ET method achieves a mean absolute error of 1.37 kcal/mol/electron when compared to the ab initio electrostatic potentials. Second, we examine the conformational dependence of the charges on over 2700 tripeptides. With the tripeptide data set, we show that the conformational effects account for approximately 0.4 kcal/mol/electron on the electrostatic potentials. Third, we test the Q ET method for its ability to reproduce the effects of polarization and electron transfer on 1000 water clusters. For the water clusters, we show that the Q ET method captures about 50% of the polarization and electron transfer effects. Finally, we examine the effects of electron transfer and polarizability on the electrostatic interaction between p38 and 94 small molecule ligands. When used in conjunction with the Generalized-Born continuum solvent model, polarization and electron transfer with the Q ET model lead to an average change of 17 kcal/mol on the calculated electrostatic component of ΔG.

  18. Clinical decision support: effectiveness in improving quality processes and clinical outcomes and factors that may influence success.

    PubMed

    Murphy, Elizabeth V

    2014-06-01

    The use of electronic health records has skyrocketed following the 2009 HITECH Act, which provides financial incentives to health care providers for the "meaningful use" of electronic medical record systems. An important component of the "Meaningful Use" legislation is the integration of Clinical Decision Support Systems (CDSS) into the computerized record, providing up-to-date medical knowledge and evidence-based guidance to the physician at the point of care. As reimbursement is increasingly tied to process and clinical outcomes, CDSS will be integral to future medical practice. Studies of CDSS indicate improvement in preventive services, appropriate care, and clinical and cost outcomes with strong evidence for CDSS effectiveness in process measures. Increasing provider adherence to CDSS recommendations is essential in improving CDSS effectiveness, and factors that influence adherence are currently under study.

  19. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2012-10-01 2012-10-01 false Digital electronic switching. 32.2212 Section...

  20. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2014-10-01 2014-10-01 false Digital electronic switching. 32.2212 Section...

  1. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2011-10-01 2011-10-01 false Digital electronic switching. 32.2212 Section...

  2. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2010-10-01 2010-10-01 false Digital electronic switching. 32.2212 Section...

  3. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2013-10-01 2013-10-01 false Digital electronic switching. 32.2212 Section...

  4. Using mobile electronic devices to deliver educational resources in developing countries.

    PubMed

    Mazal, Jonathan Robert; Ludwig, Rebecca

    2015-01-01

    Developing countries have far fewer trained radiography professionals than developed countries, which exacerbates the limited access to imaging services. The lack of trained radiographers reflects, in part, limited availability of radiographer-specific educational resources. Historically, organizations that provided such resources in the developing world faced challenges related to the limited stock of current materials as well as expenses associated with shipping and delivery. Four mobile electronic devices (MEDs) were loaded with educational content (e-books, PDFs, and digital applications) spanning major radiography topics. The MEDs were distributed to 4 imaging departments in Ghana, India, Nepal, and Nigeria based on evidence of need for radiography-specific resources, as revealed by survey responses. A cost comparison of postal delivery vs digital delivery of educational content was performed. The effectiveness of delivering additional content via Wi-Fi transmission also was evaluated. Feedback was solicited on users' experience with the MEDs as a delivery tool for educational content. An initial average per e-book expense of $30.05, which included the cost of the device, was calculated for the MED delivery method compared with $15.56 for postal delivery of printed materials. The cost of the MED delivery method was reduced to an average of $10.05 for subsequent e-book deliveries. Additional content was successfully delivered via Wi-Fi transmission to all recipients during the 3-month follow-up period. Overall user feedback on the experience was positive, and ideas for enhancing the MED-based method were identified. Using MEDs to deliver radiography-specific educational content appears to be more cost effective than postal delivery of printed materials on a long-term basis. MEDs are more efficient for providing updates to educational materials. Customization of content to department needs, and using projector devices could enhance the usefulness of MEDs for radiographer training.

  5. ITG-TEM turbulence simulation with bounce-averaged kinetic electrons in tokamak geometry

    NASA Astrophysics Data System (ADS)

    Kwon, Jae-Min; Qi, Lei; Yi, S.; Hahm, T. S.

    2017-06-01

    We develop a novel numerical scheme to simulate electrostatic turbulence with kinetic electron responses in magnetically confined toroidal plasmas. Focusing on ion gyro-radius scale turbulences with slower frequencies than the time scales for electron parallel motions, we employ and adapt the bounce-averaged kinetic equation to model trapped electrons for nonlinear turbulence simulation with Coulomb collisions. Ions are modeled by employing the gyrokinetic equation. The newly developed scheme is implemented on a global δf particle in cell code gKPSP. By performing linear and nonlinear simulations, it is demonstrated that the new scheme can reproduce key physical properties of Ion Temperature Gradient (ITG) and Trapped Electron Mode (TEM) instabilities, and resulting turbulent transport. The overall computational cost of kinetic electrons using this novel scheme is limited to 200%-300% of the cost for simulations with adiabatic electrons. Therefore the new scheme allows us to perform kinetic simulations with trapped electrons very efficiently in magnetized plasmas.

  6. Design and Performance of a Miniature Radar L-Band Transceiver

    NASA Technical Reports Server (NTRS)

    McWatters, D.; Price, D.; Edelstein, W.

    2004-01-01

    Radar electronics developed for past JPL space missions historically had been custom designed and as such, given budgetary, time, and risk constraints, had not been optimized for maximum flexibility or miniaturization. To help reduce cost and risk of future radar missions, a generic radar module was conceived. The module includes a 1.25-GHz (L-band) transceiver and incorporates miniature high-density packaging of integrated circuits in die/chip form. The technology challenges include overcoming the effect of miniaturization and high packaging density to achieve the performance, reliability, and environmental ruggedness required for space missions. The module was chosen to have representative (generic) functionality most likely required from an L-band radar. For very large aperture phased-array spaceborne radar missions, the large dimensions of the array suggest the benefit of distributing the radar electronics into the antenna array. For such applications, this technology is essential in order to bring down the cost, mass, and power of the radar electronics module replicated in each panel of the array. For smaller sized arrays, a single module can be combined with the central radar controller and still provide the bene.ts of configuration .exibility, low power, and low mass. We present the design approach for the radar electronics module and the test results for its radio frequency (RF) portion: a miniature, low-power, radiation-hard L-band transceiver.

  7. Recent progress in printed 2/3D electronic devices

    NASA Astrophysics Data System (ADS)

    Klug, Andreas; Patter, Paul; Popovic, Karl; Blümel, Alexander; Sax, Stefan; Lenz, Martin; Glushko, Oleksandr; Cordill, Megan J.; List-Kratochvil, Emil J. W.

    2015-09-01

    New, energy-saving, efficient and cost-effective processing technologies such as 2D and 3D inkjet printing (IJP) for the production and integration of intelligent components will be opening up very interesting possibilities for industrial applications of molecular materials in the near future. Beyond the use of home and office based printers, "inkjet printing technology" allows for the additive structured deposition of photonic and electronic materials on a wide variety of substrates such as textiles, plastics, wood, stone, tiles or cardboard. Great interest also exists in applying IJP in industrial manufacturing such as the manufacturing of PCBs, of solar cells, printed organic electronics and medical products. In all these cases inkjet printing is a flexible (digital), additive, selective and cost-efficient material deposition method. Due to these advantages, there is the prospect that currently used standard patterning processes can be replaced through this innovative material deposition technique. A main issue in this research area is the formulation of novel functional inks or the adaptation of commercially available inks for specific industrial applications and/or processes. In this contribution we report on the design, realization and characterization of novel active and passive inkjet printed electronic devices including circuitry and sensors based on metal nanoparticle ink formulations and the heterogeneous integration into 2/3D printed demonstrators. The main emphasis of this paper will be on how to convert scientific inkjet knowledge into industrially relevant processes and applications.

  8. COST-EFFECTIVE RARE EARTH ELEMENT RECYCLING PROCESS FROM INDUSTRIAL SCRAP AND DISCARDED ELECTRONIC PRODUCTS TO VALUABLE MAGNETIC ALLOYS AND PERMANENT MAGNETS - PHASE II

    EPA Science Inventory

    Rare earth element (REE) based Nd-Fe-B and Sm-Co permanent magnets have been widely used because of their excellent magnetic properties. The applications of Nd-Fe-B and Sm-Co rare earth permanent magnets include hybrid electric vehicles (HEVs), power generators for wind tur...

  9. 13 CFR 307.14 - Revolving Loan Fund semi-annual report and Income and Expense Statement.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... RLF Plan to ensure effective use of the RLF as a strategic financing tool. (c) RLF Income and Expense... for administrative costs in a six-month (6) Reporting Period must submit to EDA a completed Income and Expense Statement (Form ED-209I or any successor form) for that Reporting Period in electronic format...

  10. 13 CFR 307.14 - Revolving Loan Fund semi-annual report and Income and Expense Statement.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... RLF Plan to ensure effective use of the RLF as a strategic financing tool. (c) RLF Income and Expense... for administrative costs in a six-month (6) Reporting Period must submit to EDA a completed Income and Expense Statement (Form ED-209I or any successor form) for that Reporting Period in electronic format...

  11. 13 CFR 307.14 - Revolving Loan Fund semi-annual report and Income and Expense Statement.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... RLF Plan to ensure effective use of the RLF as a strategic financing tool. (c) RLF Income and Expense... for administrative costs in a six-month (6) Reporting Period must submit to EDA a completed Income and Expense Statement (Form ED-209I or any successor form) for that Reporting Period in electronic format...

  12. The Unintended Consequences of the Adoption of Electronic Medical Record Systems on Healthcare Costs

    ERIC Educational Resources Information Center

    Ganju, Kartik K.

    2016-01-01

    In my dissertation, I study unintended consequences of the adoption of EMR systems. In my three essays, I examine how the adoption of EMR systems affects neighboring hospitals (spillover effects), can be used by hospitals to further its objectives in an unconventional manner ("upcoding" of patient case mix data), and how EMR adoption may…

  13. Electron Beam Freeform Fabrication for Cost Effective Near-Net Shape Manufacturing

    NASA Technical Reports Server (NTRS)

    Taminger, Karen M.; Hafley, Robert A.

    2006-01-01

    Manufacturing of structural metal parts directly from computer aided design (CAD) data has been investigated by numerous researchers over the past decade. Researchers at NASA Langley Research Center are developing a new solid freeform fabrication process, electron beam freeform fabrication (EBF3), as a rapid metal deposition process that works efficiently with a variety of weldable alloys. EBF3 deposits of 2219 aluminium and Ti-6Al-4V have exhibited a range of grain morphologies depending upon the deposition parameters. These materials have exhibited excellent tensile properties comparable to typical handbook data for wrought plate product after post-processing heat treatments. The EBF3 process is capable of bulk metal deposition at deposition rates in excess of 2500 cm3/hr (150 in3/hr) or finer detail at lower deposition rates, depending upon the desired application. This process offers the potential for rapidly adding structural details to simpler cast or forged structures rather than the conventional approach of machining large volumes of chips to produce a monolithic metallic structure. Selective addition of metal onto simpler blanks of material can have a significant effect on lead time reduction and lower material and machining costs.

  14. Electron Beam Freeform Fabrication (EBF3) for Cost Effective Near-Net Shape Manufacturing

    NASA Technical Reports Server (NTRS)

    Taminger, Karen M.; Hafley, Robert A.

    2006-01-01

    Manufacturing of structural metal parts directly from computer aided design (CAD) data has been investigated by numerous researchers over the past decade. Researchers at NASA Langley Research Center are developing a new solid freeform fabrication process, electron beam freeform fabrication (EBF3), as a rapid metal deposition process that works efficiently with a variety of weldable alloys. EBF3 deposits of 2219 aluminium and Ti-6Al-4V have exhibited a range of grain morphologies depending upon the deposition parameters. These materials have exhibited excellent tensile properties comparable to typical handbook data for wrought plate product after post-processing heat treatments. The EBF3 process is capable of bulk metal deposition at deposition rates in excess of 2500 cubic centimeters per hour (150 in3/hr) or finer detail at lower deposition rates, depending upon the desired application. This process offers the potential for rapidly adding structural details to simpler cast or forged structures rather than the conventional approach of machining large volumes of chips to produce a monolithic metallic structure. Selective addition of metal onto simpler blanks of material can have a significant effect on lead time reduction and lower material and machining costs.

  15. Self-cleaning superhydrophobic epoxy coating based on fibrous silica-coated iron oxide magnetic nanoparticles.

    PubMed

    Alamri, Haleema; Al-Shahrani, Abdullah; Bovero, Enrico; Khaldi, Turki; Alabedi, Gasan; Obaid, Waleed; Al-Taie, Ihsan; Fihri, Aziz

    2018-03-01

    Inspired by the self-cleaning lotus leaf, a facile method of fabricating superhydrophobic silica coated magnetite nanoparticles using a cost-effective process is presented in this work. The structural characterizations and magnetic properties of the obtained core-shell magnetic nanoparticles were characterized by means of X-ray diffraction (XRD), thermal gravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and vibrating sample magnetometer (VSM). TEM analysis revealed that the particles present flower-like dendrimeric fibers morphology. The particles were uniformly dispersed on the surface of an epoxy resin coating with the purpose to increase the roughness and reduce the surface energy of the surface. The resulting superhydrophobic surface provides robust water-repellent surface under harsh conditions, thanks to its self-cleaning characteristic. The superhydrophobicity of this surface was confirmed based on the measurements of a water contact angle around 175°, which surpasses the theoretical limit of the superhydrophobicity. The simplicity and the cost-effectiveness of the process developed in this study appears to be a promising route for the preparation of other magnetic superhydrophobic organic-inorganic hybrid materials that would be beneficial in a wide variety of applications. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Quantification, dissipation behavior and risk assessment of ethion in green pea by gas chromatography-electron capture detector.

    PubMed

    Jan, Ishrat; Dar, Alamgir A; Mubashir, Sofi; Alam Wani, Ashraf; Mukhtar, Malik; Sofi, Khurshid A; Dar, Irshad H; Sofi, Javid A

    2018-05-01

    Residue investigation was carried out to scrutinize the persistence, dissipation behavior, half-life, and risk assessment of ethion on green pea fruit by spraying ethion at the fruiting stage followed by another application at 10 day intervals. The samples were extracted by using a quick, easy, low-cost, effective, rugged, and safe method, and the residues of ethion were analyzed by gas chromatography with electron capture detection. Here we report a novel, accurate, and cost-effective gas chromatography method for the determination of average deposits of ethion on green pea. The initial deposits were found to be 4.65 mg/kg following the application of insecticide. Residues of ethion reached below the detection limit of 0.10 mg/kg after 25 days at recommended dosage. The half-life of ethion was found to be 4.62 days. For risk assessment studies, the 25th day will be safe for consumers for the consumption of green peas. The developed method is simple, sensitive, selective, and repeatable and can be extended for ethion-based standardization of herbal formulations containing green pea and its use in pesticide industries. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Systematic review and cost-effectiveness evaluation of 'pill-in-the-pocket' strategy for paroxysmal atrial fibrillation compared to episodic in-hospital treatment or continuous antiarrhythmic drug therapy.

    PubMed

    Saborido, C Martin; Hockenhull, J; Bagust, A; Boland, A; Dickson, R; Todd, D

    2010-06-01

    Atrial fibrillation (AF) is a tachyarrhythmia characterised by uncoordinated atrial activation with consequent deterioration of impairment of atrial function and a rapid, irregular heartbeat. The annual incidence rate of paroxysmal AF (PAF) has been estimated at 1.0 per 1000 person-years (95% confidence interval 0.9 to 1.1), and reported prevalence rates show wide variations depending on age and country. Conventional treatment strategies for PAF focus on the suppression of paroxysms of AF and return to normal sinus rhythm. To summarise the results of the rapid reviews of the clinical effectiveness and cost-effectiveness literature describing the pill-in-the-pocket (PiP) approach for the treatment of patients with PAF; and to develop an economic model to assess the cost-effectiveness of PiP compared with in-hospital treatment (IHT) or continuous antiarrhythmic drugs (AADs) for the treatment of patients with PAF. Ovid MEDLINE and Ovid OLDMEDLINE 1950 to present with Daily Update were searched. The following electronic databases were searched for ongoing trials: Health Services Research Projects in Progress, ClinicalTrials.gov, metaRegister of Current Controlled Trials, BioMed Central, World Health Organization International Clinical Trials Registry Platform, ClinicalStudyResults.org and the National Library of Medicine Gateway. Inclusion criteria, which included patients suffering from PAF, were independently applied to all identified references by two reviewers (JH and CMS). Electronic searches were conducted to identify clinical effectiveness and cost-effectiveness evidence describing the use of a PiP strategy for the treatment of PAF, published since the release of the Royal College of Physicians' national guidelines on AF in June 2006. A Markov model was constructed to examine differences between three PAF strategies (PiP, AAD and IHT) in terms of cost per quality-adjusted life-year (QALY). A Markov model structure was chosen because it is assumed that PAF is a condition that causes patients to move between a limited number of relevant health states during their lives. The search strategies for clinical studies identified 201 randomised controlled trials (RCTs). Of the 201 RCTs identified, 12 were deemed to be relevant to the decision problem as they included drugs used to treat PAF; summary data were abstracted from these studies in order to inform the development of the economic model only. The model results indicate that the PiP strategy is slightly less effective than the other two strategies, but also less costly (incremental cost-effectiveness ratio of 45,916 pounds per QALY when compared to AAD, and 12,424 pounds per QALY when compared to IHT). The one-way sensitivity analyses performed do not show substantial changes in relative cost-effectiveness except in relation to the age of patients, where PiP dominates AAD in men over 65 years and in women over 70 years. At a threshold of 25,000 pounds per QALY, IHT has the maximum probability of being cost-effective at this threshold. For threshold values between 0 pounds and 9266 pounds per QALY, PiP is the option exhibiting the maximum probability of being cost-effective. The AAD strategy has a very poor probability of being cost-effective under any threshold. However, none of the strategies considered has more than a 40% probability of being cost-effective at a threshold of 25,000 pounds per QALY at any threshold level. This demonstrates the uncertainty around the parameters and its effect on the decision to choose any one strategy over the others. Most of the data used to populate the model have been taken from studies with populations that do not match the patient population specified in the decision problem. Populating the model in this way was unavoidable as there was a paucity of published clinical effectiveness and cost-effectiveness data describing a PiP strategy for this highly specific group of patients. Overall, a PiP strategy seems to be slightly less effective (i.e. fewer QALYs gained) than AAD and IHT, but is associated with cost savings. A PiP strategy seems to be more efficacious and cost-effective than an AAD strategy in men over 65 years and women over 70 years, but this is principally due to a very slight difference in QALY gained by the PiP strategy. A change in clinical practice that includes the introduction of PiP may save costs, but also involves a reduction in clinical effectiveness compared to existing approaches used to treat patients with PAF. Uncertainty in the available clinical data means there was insufficient evidence to support a recommendation for the use of PiP strategy in patients with PAF. Further research should identify outcomes of interest such as adverse events and recurrent AF episodes in an RCT setting because the only clinical study addressing these issues, even partially, is not an RCT but a descriptive analysis. Patient preferences also need to be considered in any future research designs.

  18. Prosthetic design directives: Low-cost hands within reach.

    PubMed

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  19. Effectiveness of demand generation interventions on use of modern contraceptives in low- and middle-income countries.

    PubMed

    Belaid, L; Dumont, A; Chaillet, N; Zertal, A; De Brouwere, V; Hounton, S; Ridde, V

    2016-10-01

    To synthesise evidence on the implementation, costs and cost-effectiveness of demand generation interventions and their effectiveness in improving uptake of modern contraception methods. A Cochrane systematic review was conducted. Searches were performed in electronic databases (MEDLINE, EMBASE) and the grey literature. Randomised controlled trials, cluster randomised trials and quasi-experimental studies, including controlled before-after studies (CBAs) and cost and cost-effectiveness studies that aimed to assess demand interventions (including community- and facility-based interventions, financial mechanisms and mass media campaigns) in low- and middle-income countries were considered. Meta-analyses and narrative synthesis were conducted. In total, 20 papers meeting the inclusion criteria were included in this review. Of those, 13 were used for meta-analysis. Few data were available on implementation and on the influence of context on demand interventions. Involving family members during counselling, providing education activities and increasing exposure to those activities could enhance the success of demand interventions. Demand generation interventions were positively associated with increases in current use (pooled OR 1.57; 95% CI: 1.46-1.69, P < 0.01). Financial mechanism interventions (vouchers) appeared effective to increase use of modern contraceptive methods (pooled OR 2.16; 95% CI: 1.91-2.45, P < 0.01; I 2 = 0%). Demand interventions improved knowledge (pooled OR 1.02; 95% CI 0.63-1.64, P = 0.93) and attitudes towards family planning and improved discussion with partners/husbands around modern contraceptive methods. However, given the limited number of studies included in each category of demand generation interventions, the dates of publication of the studies and their low quality, caution is advised in considering the results. Very limited evidence was available on costs; studies including data on costs were old and inconsistent. Demand generation interventions contribute to increases in modern contraceptive methods use. However, more studies with robust designs are needed to identify the most effective demand generation intervention to increase uptake of modern contraceptive methods. More evidence is also needed about implementation, costs and cost-effectiveness to inform decisions on sustainability and scaling-up. © 2016 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  20. The effectiveness and cost-effectiveness of clinical nurse specialists in outpatient roles: a systematic review.

    PubMed

    Kilpatrick, Kelley; Kaasalainen, Sharon; Donald, Faith; Reid, Kim; Carter, Nancy; Bryant-Lukosius, Denise; Martin-Misener, Ruth; Harbman, Patricia; Marshall, Deborah Anne; Charbonneau-Smith, Renee; DiCenso, Alba

    2014-12-01

    Increasing numbers of clinical nurse specialists (CNSs) are working in outpatient settings. The objective of this paper is to describe a systematic review of randomized controlled trials (RCTs) evaluating the cost-effectiveness of CNSs delivering outpatient care in alternative or complementary provider roles. We searched CINAHL, MEDLINE, EMBASE and seven other electronic databases, 1980 to July 2012 and hand-searched bibliographies and key journals. RCTs that evaluated formally trained CNSs and health system outcomes were included. Study quality was assessed using the Cochrane risk of bias tool and the Quality of Health Economic Studies instrument. We used the Grading of Recommendations Assessment, Development and Evaluation to assess quality of evidence for individual outcomes. Eleven RCTs, four evaluating alternative provider (n = 683 participants) and seven evaluating complementary provider roles (n = 1464 participants), were identified. Results of the alternative provider RCTs (low-to-moderate quality evidence) were fairly consistent across study populations with similar patient outcomes to usual care, some evidence of reduced resource use and costs, and two economic analyses (one fair and one high quality) favouring CNS care. Results of the complementary provider RCTs (low-to-moderate quality evidence) were also fairly consistent across study populations with similar or improved patient outcomes and mostly similar health system outcomes when compared with usual care; however, the economic analyses were weak. Low-to-moderate quality evidence supports the effectiveness and two fair-to-high quality economic analyses support the cost-effectiveness of outpatient alternative provider CNSs. Low-to-moderate quality evidence supports the effectiveness of outpatient complementary provider CNSs; however, robust economic evaluations are needed to address cost-effectiveness. © 2014 John Wiley & Sons, Ltd.

  1. Performance and cost characteristics of multi-electron transfer, common ion exchange non-aqueous redox flow batteries

    NASA Astrophysics Data System (ADS)

    Laramie, Sydney M.; Milshtein, Jarrod D.; Breault, Tanya M.; Brushett, Fikile R.; Thompson, Levi T.

    2016-09-01

    Non-aqueous redox flow batteries (NAqRFBs) have recently received considerable attention as promising high energy density, low cost grid-level energy storage technologies. Despite these attractive features, NAqRFBs are still at an early stage of development and innovative design techniques are necessary to improve performance and decrease costs. In this work, we investigate multi-electron transfer, common ion exchange NAqRFBs. Common ion systems decrease the supporting electrolyte requirement, which subsequently improves active material solubility and decreases electrolyte cost. Voltammetric and electrolytic techniques are used to study the electrochemical performance and chemical compatibility of model redox active materials, iron (II) tris(2,2‧-bipyridine) tetrafluoroborate (Fe(bpy)3(BF4)2) and ferrocenylmethyl dimethyl ethyl ammonium tetrafluoroborate (Fc1N112-BF4). These results help disentangle complex cycling behavior observed in flow cell experiments. Further, a simple techno-economic model demonstrates the cost benefits of employing common ion exchange NAqRFBs, afforded by decreasing the salt and solvent contributions to total chemical cost. This study highlights two new concepts, common ion exchange and multi-electron transfer, for NAqRFBs through a demonstration flow cell employing model active species. In addition, the compatibility analysis developed for asymmetric chemistries can apply to other promising species, including organics, metal coordination complexes (MCCs) and mixed MCC/organic systems, enabling the design of low cost NAqRFBs.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeffery, D.J.

    This report considers a wide range of possible methods for improving the route guidance information available to drivers, and for saving up to L600M per year of national resource costs which are effectively wasted by drivers who fail to select optimum routes for unfamiliar journeys. The methods considered include improvements to maps and roadsigns, both of which could prove highly cost effective although they would leave some 80 per cent of the wastage unrecovered. A substantial proportion of this remaining wastage might be avoided with a Viewdata route planning and guidance scheme which could be achieved at relatively low costmore » to public funds, or with automatic systems. Of a range of automatic electronic guidance systems considered the most cost effective solution would be provided by a system which used buried loops to provide a two-way communication link between a roadside and a vehicle unit. Such a scheme would necessarily involve a considerable investment from public funds, but would offer the greatest potential for further development and, in particular, could provide the basis of a comprehensive traffic control tool.« less

  3. Using electronic surveys in nursing research.

    PubMed

    Cope, Diane G

    2014-11-01

    Computer and Internet use in businesses and homes in the United States has dramatically increased since the early 1980s. In 2011, 76% of households reported having a computer, compared with only 8% in 1984 (File, 2013). A similar increase in Internet use has also been seen, with 72% of households reporting access of the Internet in 2011 compared with 18% in 1997 (File, 2013). This emerging trend in technology has prompted use of electronic surveys in the research community as an alternative to previous telephone and postal surveys. Electronic surveys can offer an efficient, cost-effective method for data collection; however, challenges exist. An awareness of the issues and strategies to optimize data collection using web-based surveys is critical when designing research studies. This column will discuss the different types and advantages and disadvantages of using electronic surveys in nursing research, as well as methods to optimize the quality and quantity of survey responses.

  4. 78 FR 18429 - Cost Recovery for Permit Processing, Administration, and Enforcement

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... costs on to the general public. DATES: Electronic or written comments: OSM will accept written comments... portion of the financial costs for reviewing, administering, and enforcing permits from the general public... general public.'' This charge is designed ``to recover the full cost to the Federal Government for...

  5. Consortium Purchases: Case Study for a Cost-Benefit Analysis.

    ERIC Educational Resources Information Center

    Scigliano, Marisa

    2002-01-01

    Discusses library cooperation and academic library consortia and presents a case study of a Canadian consortia that conducted a cost-benefit analysis for purchasing an electronic resource. Reports on member library subscription costs, external economic factors, value of patron time saved, costs and benefits for patrons, and net savings. (LRW)

  6. Cost-effectiveness of cell salvage and alternative methods of minimising perioperative allogeneic blood transfusion: a systematic review and economic model.

    PubMed

    Davies, L; Brown, T J; Haynes, S; Payne, K; Elliott, R A; McCollum, C

    2006-11-01

    To compare patient outcomes, resource use and costs to the NHS and NHS Blood Transfusion Authority (BTA) associated with cell salvage and alternative methods of minimising perioperative allogeneic blood transfusion. Electronic databases covering the period 1996-2004 for systematic reviews and 1994-2004 for economic evidence. Existing systematic reviews were updated with data from selected randomised controlled trials (RCTs) that involved adults scheduled for elective non-urgent surgery. Any resource use or cost data were extracted for potential use in populating an economic model. Relative risks or weighted mean difference of each outcome for each intervention were assessed, taking into account the number of RCTs included in each outcome and intervention and the presence of any heterogeneity. This allowed indirect comparison of the relative effectiveness of each intervention when the intervention is compared with allogeneic blood transfusion. A decision analytic model synthesised clinical and economic data from several sources, to estimate the relative cost-effectiveness of cell salvage for people undergoing elective surgery with moderate to major expected blood loss. The perspective of the NHS and patients and a time horizon of 1 month were used. The economic model was developed from reviews of effectiveness and cost-effectiveness and clinical experts. Secondary analysis explored the robustness of the results to changes in the timing and costs of cell salvage equipment, surgical procedure, use of transfusion protocols and time horizon of analysis. Overall, 668 studies were identified electronically for the update of the two systematic reviews. This included five RCTs, of which two were cell salvage and three preoperative autologous donation (PAD). Five published systematic reviews were identified for antifibrinolytics, fibrin sealants and restrictive transfusion triggers, PAD plus erythropoietin, erythropoietin alone and acute normovolaemic haemodilution (ANH). Twelve published studies reported full economic evaluations. All but two of the transfusion strategies significantly reduced exposure to allogeneic blood. The relative risk of exposure to allogeneic blood was 0.59 for the pooled trials of cell salvage (95% confidence interval: 0.48 to 0.73). This varied by the type and timing of cell salvage and type of surgical procedure. For cell salvage, the relative risk of allogeneic blood transfusion was higher in cardiac surgery than in orthopaedic surgery. Cell salvage had lower costs and slightly higher quality-adjusted life years compared with all of the alternative transfusion strategies except ANH. The likelihood that cell salvage is cost-effective compared with strategies other than ANH is over 50%. Most of the secondary analyses indicated similar results to the primary analysis. However, the primary and secondary analyses indicated that ANH may be more cost-effective than cell salvage. The available evidence indicates that cell salvage may be a cost-effective method to reduce exposure to allogeneic blood transfusion. However, ANH may be more cost-effective than cell salvage. The results of this analysis are subject to the low quality and reliability of the data used and the use of indirect comparisons. This may affect the reliability and robustness of the clinical and economic results. There is a need for further research that includes adequately powered high-quality RCTs to compare directly various blood transfusion strategies. These should include measures of health status, health-related quality of life and patient preferences for alternative transfusion strategies. Observational and tracking studies are needed to estimate reliably the incidence of adverse events and infections transmitted during blood transfusion and to identify the lifetime consequences of the serious hazards of transfusion on mortality, health status and health-related quality of life.

  7. Advanced electric propulsion system concept for electric vehicles. Addendum 1: Voltage considerations

    NASA Technical Reports Server (NTRS)

    Raynard, A. E.; Forbes, F. E.

    1980-01-01

    The two electric vehicle propulsion systems that best met cost and performance goals were examined to assess the effect of battery pack voltage on system performance and cost. A voltage range of 54 to 540 V was considered for a typical battery pack capacity of 24 k W-hr. The highest battery specific energy (W-hr/kg) and the lowest cost ($/kW-hr) were obtained at the minimum voltage level. The flywheel system traction motor is a dc, mechanically commutated with shunt field control, and due to the flywheel the traction motor and the battery are not subject to extreme peaks of power demand. The basic system uses a permanent-magnet motor with electronic commutation supplied by an ac power control unit. In both systems battery cost were the major factor in system voltage selection, and a battery pack with the minimum voltage of 54 V produced the lowest life-cycle cost. The minimum life-cycle cost for the basic system with lead-acid batteries was $0.057/km and for the flywheel system was $0.037/km.

  8. Prototyping Instruments for Chemical Laboratory Using Inexpensive Electronic Modules.

    PubMed

    Urban, Pawel L

    2018-05-15

    Open-source electronics and programming can augment chemical and biomedical research. Currently, chemists can choose from a broad range of low-cost universal electronic modules (microcontroller boards and single-board computers) and use them to assemble working prototypes of scientific tools to address specific experimental problems and to support daily research work. The learning time can be as short as a few hours, and the required budget is often as low as 50 USD. Prototyping instruments using low-cost electronic modules gives chemists enormous flexibility to design and construct customized instrumentation, which can reduce the delays caused by limited access to high-end commercial platforms. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Ka-Band Multibeam Aperture Phased Array Being Developed

    NASA Technical Reports Server (NTRS)

    Reinhart, Richard C.; Kacpura, Thomas J.

    2004-01-01

    Phased-array antenna systems offer many advantages to low-Earth-orbiting satellite systems. Their large scan angles and multibeam capabilities allow for vibration-free, rapid beam scanning and graceful degradation operation for high rate downlink of data to users on the ground. Technology advancements continue to reduce the power, weight, and cost of these systems to make phased arrays a competitive alternative in comparison to the gimbled reflector system commonly used in science missions. One effort to reduce the cost of phased arrays is the development of a Ka-band multibeam aperture (MBA) phased array by Boeing Corporation under a contract jointly by the NASA Glenn Research Center and the Office of Naval Research. The objective is to develop and demonstrate a space-qualifiable dual-beam Ka-band (26.5-GHz) phased-array antenna. The goals are to advance the state of the art in Ka-band active phased-array antennas and to develop and demonstrate multibeam transmission technology compatible with spacecraft in low Earth orbit to reduce the cost of future missions by retiring certain development risks. The frequency chosen is suitable for space-to-space and space-to-ground communication links. The phased-array antenna has a radiation pattern designed by combining a set of individual radiating elements, optimized with the type of radiating elements used, their positions in space, and the amplitude and phase of the currents feeding the elements. This arrangement produces a directional radiation pattern that is proportional to the number of individual radiating elements. The arrays of interest here can scan the main beam electronically with a computerized algorithm. The antenna is constructed using electronic components with no mechanical parts, and the steering is performed electronically, without any resulting vibration. The speed of the scanning is limited primarily by the control electronics. The radiation performance degrades gracefully if a portion of the elements fail. The arrays can be constructed to conform to a mounting surface, and multibeam capability is integral to the design. However, there are challenges for mission designers using monolithic-microwave-integrated-circuit- (MMIC-) based arrays because of reduced power efficiency, higher costs, and certain system effects that result in link degradations. The multibeam aperture phased-array antenna development is attempting to address some of these issues, particularly manufacturing, costs, and system performance.

  10. The effectiveness and cost-effectiveness of parent training/education programmes for the treatment of conduct disorder, including oppositional defiant disorder, in children.

    PubMed

    Dretzke, J; Frew, E; Davenport, C; Barlow, J; Stewart-Brown, S; Sandercock, J; Bayliss, S; Raftery, J; Hyde, C; Taylor, R

    2005-12-01

    To assess the clinical and cost-effectiveness of parent training programmes for the treatment of children with conduct disorder (CD) up to the age of 18 years. Electronic databases. For the effectiveness review, relevant studies were identified and evaluated. A quantitative synthesis of behavioural outcomes across trials was also undertaken using two approaches: vote counting and meta-analysis. The economic analysis consisted of reviewing previous economic/cost evaluations of parent training/education programmes and the economic information within sponsor's submissions; carrying out a detailed exploration of costs of parent training/education programmes; and a de novo modelling assessment of the cost-effectiveness of parent training/education programmes. The potential budget impact to the health service of implementing such programmes was also considered. Many of the 37 randomised controlled trials that met the review inclusion and exclusion criteria were assessed as being of poor methodological quality. Studies were clinically heterogeneous in terms of the population, type of parent training/education programme and content, setting, delivery, length and child behaviour outcomes used. Both vote counting and meta-analysis revealed a consistent trend across all studies towards short-term effectiveness (up to 4 months) of parent training/education programmes (compared with control) as measured by a change in child behaviour. Pooled estimates showed a statistically significant improvement on the Eyberg Child Behaviour Inventory frequency and intensity scales, the Dyadic Parent-Child Interaction Coding System and the Child Behaviour Checklist. No studies reported a statistically significant result favouring control over parent training/education programmes. There were few statistically significant differences between different parent training/education programmes, although there was a trend towards more intensive interventions (e.g. longer contact hours, additional child involvement) being more effective. The cost of treating CD is high, with costs incurred by many agencies. A recent study suggested that by age 28, costs for individuals with CD were around 10 times higher than for those with no problems, with a mean cost of 70,019 pounds sterling. Criminality incurs the greatest cost, followed by educational provision, foster and residential care and state benefits. Only a small proportion of these costs fall on health services. Using a 'bottom-up' costing approach, the costs per family of providing parent training/education programmes range from 629 pounds sterling to 3839 pounds sterling depending on the type and style of delivery. Using the conservative assumption that there are no cost savings from treatment, a total lifetime quality of life gain of 0.1 would give a cost per quality-adjusted life-year of between 38,393 pounds sterling and 6288 pounds sterling depending on the type of programme delivery and setting. Parent training/education programmes appear to be an effective and potentially cost-effective therapy for children with CD. However, the relative effectiveness and cost-effectiveness of different models (such as therapy intensity and setting) require further investigation. Further research is required on the impact of parent training/education programmes on the quality of life of children with CD and their parents/carers, as well as on longer term child outcomes.

  11. Effect of Ni doping on structural and optical properties of Zn{sub 1−x}Ni{sub x}O nanopowder synthesized via low cost sono-chemical method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Budhendra, E-mail: bksingh@ua.pt; Kaushal, Ajay, E-mail: ajay.kaushal@ua.pt; Bdikin, Igor

    2015-10-15

    Highlights: • Pure and Ni doped ZnO nanopowders were synthesized by low cost sonochemical method. • The optical properties of Zn{sub 1−x}Ni{sub x}O nanopowders can be tuned by varying Ni content. • The results reveal the solubility limit of Ni into ZnO matrix as below 8%. - Abstract: Zn{sub 1−x}Ni{sub x}O nanopowders with different Ni contents of x = 0.0, 0.04 and 0.08 were synthesized via cost effective sonochemical reaction method. X-ray diffraction (XRD) pattern reveals pure wurtzite phase of prepared nanostructures with no additional impurity peaks. The morphology and dimensions of nanoparticles were investigated using scanning electron microscope (SEM).more » A sharp and strong peak for first order optical mode for wurtzite zinc oxide (ZnO) structure was observed at ∼438 cm{sup −1} in Raman spectra. The calculated optical band gap (E{sub g}) from UV–vis transmission data was found to decrease with increase in Ni content. The observed red shift in E{sub g} with increasing Ni content in ZnO nanopowders were in agreement with band gap behaviours found in their photoluminescence (PL) spectra. The synthesised ZnO nanopowders with controlled band gap on Ni doping reveals their potential for use in various electronic and optical device applications. The results were discussed in detail.« less

  12. Are cardiovascular disease risk assessment and management programmes cost effective? A systematic review of the evidence.

    PubMed

    Lee, John Tayu; Lawson, Kenny D; Wan, Yizhou; Majeed, Azeem; Morris, Stephen; Soljak, Michael; Millett, Christopher

    2017-06-01

    The World Health Organization recommends that countries implement population-wide cardiovascular disease (CVD) risk assessment and management programmes. The aim of this study was to conduct a systematic review to evaluate whether this recommendation is supported by cost-effectiveness evidence. Published economic evaluations were identified via electronic medical and social science databases (including Medline, Web of Science, and the NHS Economic Evaluation Database) from inception to March 2016. Study quality was evaluated using a modified version of the Consolidated Health Economic Evaluation Reporting Standards. Fourteen economic evaluations were included: five studies based on randomised controlled trials, seven studies based on observational studies and two studies using hypothetical modelling synthesizing secondary data. Trial based studies measured CVD risk factor changes over 1 to 3years, with modelled projections of longer term events. Programmes were either not, or only, cost-effective under non-verified assumptions such as sustained risk factor changes. Most observational and hypothetical studies suggested programmes were likely to be cost-effective; however, study deigns are subject to bias and subsequent empirical evidence has contradicted key assumptions. No studies assessed impacts on inequalities. In conclusion, recommendations for population-wide risk assessment and management programmes lack a robust, real world, evidence basis. Given implementation is resource intensive there is a need for robust economic evaluation, ideally conducted alongside trials, to assess cost effectiveness. Further, the efficiency and equity impact of different delivery models should be investigated, and also the combination of targeted screening with whole population interventions recognising that there multiple approaches to prevention. Copyright © 2017. Published by Elsevier Inc.

  13. Development of a Low-cost, FPGA-based, Delay Line Particle Detector for Satellite and Sounding Rocket Applications

    NASA Astrophysics Data System (ADS)

    Harrington, M.; Kujawski, J. T.; Adrian, M. L.; Weatherwax, A. T.

    2013-12-01

    Electrons are, by definition, a fundamental, chemical and electromagnetic constituent of any plasma. This is especially true within the partially ionized plasmas of Earth's ionosphere where electrons are a critical component of a vast array of plasma processes. Siena College is working on a novel method of processing information from electron spectrometer anodes using delay line techniques and inexpensive COTS electronics to track the movement of high-energy particles. Electron spectrometers use a variety of techniques to determine where an amplified electron cloud falls onto a collecting surface. One traditional method divides the collecting surface into sectors and uses a single detector for each sector. However, as the angular and spatial resolution increases, so does the number of detectors, increasing power consumption, cost, size, and weight of the system. An alternative approach is to connect each sector with a delay line built within the PCB material which is shielded from cross talk by a flooded ground plane. Only one pair of detectors (e.g., one at each end of the chain) are needed with the delay line technique which is different from traditional delay line detectors which use either Application Specific Integrated Circuits (ASICs) or very fast clocks. In this paper, we report on the implementation and testing of a delay line detector using a low-cost Xilinx FPGA and a thirty-two sector delay system. This Delay Line Detector has potential satellite and rocket flight applications due to its low cost, small size and power efficiency

  14. Radiation-tolerant imaging device

    DOEpatents

    Colella, N.J.; Kimbrough, J.R.

    1996-11-19

    A barrier at a uniform depth for an entire wafer is used to produce imaging devices less susceptible to noise pulses produced by the passage of ionizing radiation. The barrier prevents charge created in the bulk silicon of a CCD detector or a semiconductor logic or memory device from entering the collection volume of each pixel in the imaging device. The charge barrier is a physical barrier, a potential barrier, or a combination of both. The physical barrier is formed by an SiO{sub 2} insulator. The potential barrier is formed by increasing the concentration of majority carriers (holes) to combine with the electron`s generated by the ionizing radiation. A manufacturer of CCD imaging devices can produce radiation-tolerant devices by merely changing the wafer type fed into his process stream from a standard wafer to one possessing a barrier beneath its surface, thus introducing a very small added cost to his production cost. An effective barrier type is an SiO{sub 2} layer. 7 figs.

  15. Improving Short Term Instability for Quantitative Analyses with Portable Electronic Noses

    PubMed Central

    Macías, Miguel Macías; Agudo, J. Enrique; Manso, Antonio García; Orellana, Carlos Javier García; Velasco, Horacio Manuel González; Caballero, Ramón Gallardo

    2014-01-01

    One of the main problems when working with electronic noses is the lack of reproducibility or repeatability of the sensor response, so that, if this problem is not properly considered, electronic noses can be useless, especially for quantitative analyses. On the other hand, irreproducibility is increased with portable and low cost electronic noses where laboratory equipment like gas zero generators cannot be used. In this work, we study the reproducibility of two portable electronic noses, the PEN3 (commercial) and CAPINose (a proprietary design) by using synthetic wine samples. We show that in both cases short term instability associated to the sensors' response to the same sample and under the same conditions represents a major problem and we propose an internal normalization technique that, in both cases, reduces the variability of the sensors' response. Finally, we show that the normalization proposed seems to be more effective in the CAPINose case, reducing, for example, the variability associated to the TGS2602 sensor from 12.19% to 2.2%. PMID:24932869

  16. CRT electron-optical system

    NASA Astrophysics Data System (ADS)

    Shirai, Shoji

    1995-09-01

    CRT is the most successful electron optical system, commercially. Over a hundred million systems are produced each year, and distributed to the whole world as television sets or personal computers. Therefore, the system has to be extremely cost and power effective, and ergonomics is the important issue at its design. Also, CRT has to be bright enough to be watched in the luminous living or office room. Therefore, electron beam current and anode voltage (CRT screen voltage) are as high as 0.5 to 7 mA and 20 to 33 kV, respectively. These unique restrictions cause unique electron lens design such as in-line rotationally asymmetrical lens or dynamic quadrupole lens and deflection yoke design such as self converging deflection yoke which produces barrel shaped vertical and pin-cushion shaped horizontal magnetic fields. In this paper the recent technical advancement and future trends of the CRT electron optical system will be discussed. The discussion will be restricted only to the picture tube, and other devices such as camera tube, oscilloscope tube will be excluded.

  17. Sandwiched confinement of quantum dots in graphene matrix for efficient electron transfer and photocurrent production

    PubMed Central

    Zhu, Nan; Zheng, Kaibo; Karki, Khadga J.; Abdellah, Mohamed; Zhu, Qiushi; Carlson, Stefan; Haase, Dörthe; Žídek, Karel; Ulstrup, Jens; Canton, Sophie E.; Pullerits, Tõnu; Chi, Qijin

    2015-01-01

    Quantum dots (QDs) and graphene are both promising materials for the development of new-generation optoelectronic devices. Towards this end, synergic assembly of these two building blocks is a key step but remains a challenge. Here, we show a one-step strategy for organizing QDs in a graphene matrix via interfacial self-assembly, leading to the formation of sandwiched hybrid QD-graphene nanofilms. We have explored structural features, electron transfer kinetics and photocurrent generation capacity of such hybrid nanofilms using a wide variety of advanced techniques. Graphene nanosheets interlink QDs and significantly improve electronic coupling, resulting in fast electron transfer from photoexcited QDs to graphene with a rate constant of 1.3 × 109 s−1. Efficient electron transfer dramatically enhances photocurrent generation in a liquid-junction QD-sensitized solar cell where the hybrid nanofilm acts as a photoanode. We thereby demonstrate a cost-effective method to construct large-area QD-graphene hybrid nanofilms with straightforward scale-up potential for optoelectronic applications. PMID:25996307

  18. Power SEMICONDUCTORS—STATE of Art and Future Trends

    NASA Astrophysics Data System (ADS)

    Benda, Vitezslav

    2011-06-01

    The importance of effective energy conversion control, including power generation from renewable and environmentally clean energy sources, increases due to rising energy demand. Power electronic systems for controlling and converting electrical energy have become the workhorse of modern society in many applications, both in industry and at home. Power electronics plays a very important role in traction and can be considered as brawns of robotics and automated manufacturing systems. Power semiconductor devices are the key electronic components used in power electronic systems. Advances in power semiconductor technology have improved the efficiency, size, weight and cost of power electronic systems. At present, IGCTs, IGBTs, and MOSFETs represent modern switching devices. Power integrated circuits (PIC) have been developed for the use of power converters for portable, automotive and aerospace applications. For advanced applications, new materials (SiC and GaN) have been introduced. This paper reviews the state of these devices and elaborates on their potentials in terms of higher voltages, higher power density, and better switching performance.

  19. Sandwiched confinement of quantum dots in graphene matrix for efficient electron transfer and photocurrent production

    NASA Astrophysics Data System (ADS)

    Zhu, Nan; Zheng, Kaibo; Karki, Khadga J.; Abdellah, Mohamed; Zhu, Qiushi; Carlson, Stefan; Haase, Dörthe; Žídek, Karel; Ulstrup, Jens; Canton, Sophie E.; Pullerits, Tõnu; Chi, Qijin

    2015-05-01

    Quantum dots (QDs) and graphene are both promising materials for the development of new-generation optoelectronic devices. Towards this end, synergic assembly of these two building blocks is a key step but remains a challenge. Here, we show a one-step strategy for organizing QDs in a graphene matrix via interfacial self-assembly, leading to the formation of sandwiched hybrid QD-graphene nanofilms. We have explored structural features, electron transfer kinetics and photocurrent generation capacity of such hybrid nanofilms using a wide variety of advanced techniques. Graphene nanosheets interlink QDs and significantly improve electronic coupling, resulting in fast electron transfer from photoexcited QDs to graphene with a rate constant of 1.3 × 109 s-1. Efficient electron transfer dramatically enhances photocurrent generation in a liquid-junction QD-sensitized solar cell where the hybrid nanofilm acts as a photoanode. We thereby demonstrate a cost-effective method to construct large-area QD-graphene hybrid nanofilms with straightforward scale-up potential for optoelectronic applications.

  20. New Advancements in the Study of the Uniform Electron Gas with Full Configuration Interaction Quantum Monte Carlo

    NASA Astrophysics Data System (ADS)

    Ruggeri, Michele; Luo, Hongjun; Alavi, Ali

    Full Configuration Interaction Quantum Monte Carlo (FCIQMC) is able to give remarkably accurate results in the study of atoms and molecules. The study of the uniform electron gas (UEG) on the other hand has proven to be much harder, particularly in the low density regime. The source of this difficulty comes from the strong interparticle correlations that arise at low density, and essentially forbid the study of the electron gas in proximity of Wigner crystallization. We extend a previous study on the three dimensional electron gas computing the energy of a fully polarized gas for N=27 electrons at high and medium density (rS = 0 . 5 to 5 . 0). We show that even when dealing with a polarized UEG the computational cost of the study of systems with rS > 5 . 0 is prohibitive; in order to deal with correlations and to extend the density range that to be studied we introduce a basis of localized states and an effective transcorrelated Hamiltonian.

  1. Formation of structure, phase composition and properties of electro explosion resistant coatings using electron-beam processing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Romanov, Denis A., E-mail: romanov-da@physics.sibsiu.ru, E-mail: kos2906@mail.ru, E-mail: budovskih-ea@physics.sibsiu.ru, E-mail: gromov@physics.sibsiu.ru, E-mail: da-rom@live.ru; Sosnin, Kirill V., E-mail: romanov-da@physics.sibsiu.ru, E-mail: kos2906@mail.ru, E-mail: budovskih-ea@physics.sibsiu.ru, E-mail: gromov@physics.sibsiu.ru, E-mail: da-rom@live.ru; Budovskikh, Evgenij A., E-mail: romanov-da@physics.sibsiu.ru, E-mail: kos2906@mail.ru, E-mail: budovskih-ea@physics.sibsiu.ru, E-mail: gromov@physics.sibsiu.ru, E-mail: da-rom@live.ru

    2014-11-14

    For the first time, the high intensity electron beam modification of electroexplosion composite coatings of MoCu, MoCCu, WCu, WCCu and TiB{sub 2}Cu systems was done. The studies of phase and elemental composition, defective structure conditions of these coatings were carried out. The regimes of electron-beam processing making possible to form the dense, specular luster surface layers having a submicrocrystalline structure were revealed. It was established that electron-beam processing of elecroexplosion spraying of layer of elecroexplosion spraying carried out in the regime of melting results in the formation of structurally and contrationally homogeneous surface layer. Investigation of the effect of electron-beammore » processing of electroexplosion electroerosion resistant coatings on their tribological properties (wear resistanse and coefficient of friction) and electroerosion resistance was done. It was shown that all the examined costings demonstrate the increase of electroerosion resistance in spark erosion up to 10 times.« less

  2. Statistical Policy Working Paper 24. Electronic Dissemination of Statistical Data

    DOT National Transportation Integrated Search

    1995-11-01

    The report, Statistical Policy Working Paper 24, Electronic Dissemination of Statistical Data, includes several topics, such as Options and Best Uses for Different Media Operation of Electronic Dissemination Service, Customer Service Programs, Cost a...

  3. Organic materials for printed electronics

    NASA Astrophysics Data System (ADS)

    Berggren, M.; Nilsson, D.; Robinson, N. D.

    2007-01-01

    Organic materials can offer a low-cost alternative for printed electronics and flexible displays. However, research in these systems must exploit the differences - via molecular-level control of functionality - compared with inorganic electronics if they are to become commercially viable.

  4. Is fenofibrate a cost-saving treatment for middle-aged individuals with type 2 diabetes? A South African private-sector perspective.

    PubMed

    Wessels, Francois

    2010-01-01

    This project was based on the FIELD trial. It is a localisation of the study by Carrington and Stewart. The aim of the original study was to determine the impact of fenofibrate therapy on healthcare costs of middle-aged patients with type 2 diabetes at high risk of future cardiovascular events. The methodology used in the Carrington article was adopted for this study. The clinical foundation for the analysis was derived from the findings of the FIELD study. All costs were sourced from electronic databases obtained from private-sector South African funders of healthcare. Event costs for the cardiovascular events were determined and added to the treatment costs for the individual treatment arms. The cost saving was determined as the difference between the event costs saved and the additional treatment costs associated with fenofibrate treatment. All costs were reported as 2008 ZAR and a discount rate of 10% was used. The study adopted a South African private-sector funder perspective. If the same approach is followed as in the Carrington and Stewart study, a cost saving of 18% results. This is the difference between the total costs associated with the placebo and fenofibrate arms, respectively (R3 480 471 compared to R2 858 598 per 1 000 patient years for the placebo and fenofibrate arms, respectively). The total costs were determined as the sum of associated event costs and treatment costs for each of the comparators. Based on this exploratory analysis, it seems that Lipanthyl treatment in middle-aged patients resulted in a cost saving due to the prevention of cardiovascular events when it was used in the treatment of type 2 diabetics, as in the FIELD study. It should therefore be considered to be cost effective, even when just the cardiovascular risk reduction effect is considered.

  5. The ERL-based Design of Electron-Hadron Collider eRHIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ptitsyn, Vadim

    2016-06-01

    Recent developments of the ERL-based design of future high-luminosity electron-hadron collider eRHIC focused on balancing technological risks present in the design versus the design cost. As a result a lower risk design has been adopted at moderate cost increase. The modifications include a change of the main linac RF frequency, reduced number of SRF cavity types and modified electron spin transport using a spin rotator. A luminosity-staged approach is being explored with a Nominal design (more » $$L \\sim 10^{33} {\\rm cm}^2 {\\rm s}^{-1}$$) that employs reduced electron current and could possibly be based on classical electron cooling, and then with the Ultimate design ($$L \\gt 10^{34} {\\rm cm}^{-2} {\\rm s}^{-1}$$) that uses higher electron current and an innovative cooling technique (CeC). The paper describes the recent design modifications, and presents the full status of the eRHIC ERL-based design.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narumanchi, Sreekant

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, andmore » in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Narumanchi, Sreekant

    Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil -- by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, andmore » in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines will be presented.« less

  8. Development of a module for point-of-care charge capture and submission using an anesthesia information management system.

    PubMed

    Reich, David L; Kahn, Ronald A; Wax, David; Palvia, Tanuj; Galati, Maria; Krol, Marina

    2006-07-01

    The use of electronic charge vouchers in anesthesia practice is limited, and the effects on practice management are unreported. The authors hypothesized that the new billing technology would improve the effectiveness of the billing interface and enhance financial practice management measures. A custom application was created to extract billing elements from the anesthesia information management system. The application incorporates business rules to determine whether individual cases have all required elements for a complete and compliant bill. The metrics of charge lag and days in accounts receivable were assessed before and after the implementation of the electronic charge voucher system. The average charge lag decreased by 7.3 days after full implementation. The total days in accounts receivable, controlling for fee schedule changes and credit balances, decreased by 10.1 days after implementation, representing a one-time revenue gain equivalent to 3.0% of total annual receipts. There are additional ongoing cost savings related to reduction of personnel and expenses related to paper charge voucher handling. Anesthesia information management systems yield financial and operational benefits by speeding up the revenue cycle and by reducing direct costs and compliance risks related to the billing and collection processes. The observed reductions in charge lag and days in accounts receivable may be of benefit in calculating the return on investment that is attributable to the adoption of anesthesia information management systems and electronic charge transmission.

  9. A generalized electron energy probability function for inductively coupled plasmas under conditions of nonlocal electron kinetics

    NASA Astrophysics Data System (ADS)

    Mouchtouris, S.; Kokkoris, G.

    2018-01-01

    A generalized equation for the electron energy probability function (EEPF) of inductively coupled Ar plasmas is proposed under conditions of nonlocal electron kinetics and diffusive cooling. The proposed equation describes the local EEPF in a discharge and the independent variable is the kinetic energy of electrons. The EEPF consists of a bulk and a depleted tail part and incorporates the effect of the plasma potential, Vp, and pressure. Due to diffusive cooling, the break point of the EEPF is eVp. The pressure alters the shape of the bulk and the slope of the tail part. The parameters of the proposed EEPF are extracted by fitting to measure EEPFs (at one point in the reactor) at different pressures. By coupling the proposed EEPF with a hybrid plasma model, measurements in the gaseous electronics conference reference reactor concerning (a) the electron density and temperature and the plasma potential, either spatially resolved or at different pressure (10-50 mTorr) and power, and (b) the ion current density of the electrode, are well reproduced. The effect of the choice of the EEPF on the results is investigated by a comparison to an EEPF coming from the Boltzmann equation (local electron kinetics approach) and to a Maxwellian EEPF. The accuracy of the results and the fact that the proposed EEPF is predefined renders its use a reliable alternative with a low computational cost compared to stochastic electron kinetic models at low pressure conditions, which can be extended to other gases and/or different electron heating mechanisms.

  10. High-Temperature High-Power Packaging Techniques for HEV Traction Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barlow, F.D.; Elshabini, A.

    A key issue associated with the wider adoption of hybrid-electric vehicles (HEV) and plug in hybrid-electric vehicles (PHEV) is the implementation of the power electronic systems that are required in these products [1]. To date, many consumers find the adoption of these technologies problematic based on a financial analysis of the initial cost versus the savings available from reduced fuel consumption. Therefore, one of the primary industry goals is the reduction in the price of these vehicles relative to the cost of traditional gasoline powered vehicles. Part of this cost reduction must come through optimization of the power electronics requiredmore » by these vehicles. In addition, the efficiency of the systems must be optimized in order to provide the greatest range possible. For some drivers, any reduction in the range associated with a potential HEV or PHEV solution in comparison to a gasoline powered vehicle represents a significant barrier to adoption and the efficiency of the power electronics plays an important role in this range. Likewise, high efficiencies are also important since lost power further complicates the thermal management of these systems. Reliability is also an important concern since most drivers have a high level of comfort with gasoline powered vehicles and are somewhat reluctant to switch to a less proven technology. Reliability problems in the power electronics or associated components could not only cause a high warranty cost to the manufacturer, but may also taint these technologies in the consumer's eyes. A larger vehicle offering in HEVs is another important consideration from a power electronics point of view. A larger vehicle will need more horsepower, or a larger rated drive. In some ways this will be more difficult to implement from a cost and size point of view. Both the packaging of these modules and the thermal management of these systems at competitive price points create significant challenges. One way in which significant cost reduction of these systems could be achieved is through the use of a single coolant loop for both the power electronics as well as the internal combustion engine (ICE) [2]. This change would reduce the complexity of the cooling system which currently relies on two loops to a single loop [3]. However, the current nominal coolant temperature entering these inverters is 65 C [3], whereas a normal ICE coolant temperature would be much higher at approximately 100 C. This change in coolant temperature significantly increases the junction temperatures of the devices and creates a number of challenges for both device fabrication and the assembly of these devices into inverters and converters for HEV and PHEV applications. With this change in mind, significant progress has been made on the use of SiC devices for inverters that can withstand much higher junction temperatures than traditional Si based inverters [4,5,6]. However, a key problem which the single coolant loop and high temperature devices is the effective packaging of these devices and related components into a high temperature inverter. The elevated junction temperatures that exist in these modules are not compatible with reliable inverters based on existing packaging technology. This report seeks to provide a literature survey of high temperature packaging and to highlight the issues related to the implementation of high temperature power electronic modules for HEV and PHEV applications. For purposes of discussion, it will be assumed in this report that 200 C is the targeted maximum junction temperature.« less

  11. Benchmark calculations of excess electrons in water cluster cavities: balancing the addition of atom-centered diffuse functions versus floating diffuse functions.

    PubMed

    Zhang, Changzhe; Bu, Yuxiang

    2016-09-14

    Diffuse functions have been proved to be especially crucial for the accurate characterization of excess electrons which are usually bound weakly in intermolecular zones far away from the nuclei. To examine the effects of diffuse functions on the nature of the cavity-shaped excess electrons in water cluster surroundings, both the HOMO and LUMO distributions, vertical detachment energies (VDEs) and visible absorption spectra of two selected (H2O)24(-) isomers are investigated in the present work. Two main types of diffuse functions are considered in calculations including the Pople-style atom-centered diffuse functions and the ghost-atom-based floating diffuse functions. It is found that augmentation of atom-centered diffuse functions contributes to a better description of the HOMO (corresponding to the VDE convergence), in agreement with previous studies, but also leads to unreasonable diffuse characters of the LUMO with significant red-shifts in the visible spectra, which is against the conventional point of view that the more the diffuse functions, the better the results. The issue of designing extra floating functions for excess electrons has also been systematically discussed, which indicates that the floating diffuse functions are necessary not only for reducing the computational cost but also for improving both the HOMO and LUMO accuracy. Thus, the basis sets with a combination of partial atom-centered diffuse functions and floating diffuse functions are recommended for a reliable description of the weakly bound electrons. This work presents an efficient way for characterizing the electronic properties of weakly bound electrons accurately by balancing the addition of atom-centered diffuse functions and floating diffuse functions and also by balancing the computational cost and accuracy of the calculated results, and thus is very useful in the relevant calculations of various solvated electron systems and weakly bound anionic systems.

  12. Using Electronic Medical Records to Assess the Effectiveness of Pharmacotherapy in Pain: A Review of Recent Observational Studies.

    PubMed

    Biltaji, Eman; Tak, Casey; Ma, Junjie; Ruiz-Negron, Natalia; Bellows, Brandon K

    2016-09-01

    Pain disorders affect a large number of individuals throughout the world and are costly. Although randomized clinical trials assess the efficacy (i.e., how well treatments work in controlled settings) of pain pharmacotherapy, clinical trials do not assess effectiveness (i.e., how well treatments work in real-world settings). The number of observational studies that use real-world data to assess the effectiveness of medications is increasing rapidly in many disease areas. It is important for clinicians to understand how real-world data may be used to assess the effectiveness of medications. This paper aims to review the current body of literature assessing the effectiveness of pain pharmacotherapy using medical records. To do this, a literature search was conducted to identify papers published between January 2013 and September 2015 that examined the effectiveness of pain pharmacotherapy using electronic medical records. The search found only three papers meeting these criteria, which were described, reviewed, and critiqued in this paper. Electronic medical records are an underutilized source of data to assess pain outcomes in real-world settings. Although there are many methodological challenges in using these data, there is also great opportunity to impact clinical practice and explore the real-world effectiveness of pharmacotherapy used in pain management.

  13. Pulsed Laser System to Simulate Effects of Cosmic Rays in Semiconductor Devices

    NASA Technical Reports Server (NTRS)

    Aveline, David C.; Adell, Philippe C.; Allen, Gregory R.; Guertin, Steven M.; McClure, Steven S.

    2011-01-01

    Spaceflight system electronic devices must survive a wide range of radiation environments with various particle types including energetic protons, electrons, gamma rays, x-rays, and heavy ions. High-energy charged particles such as heavy ions can pass straight through a semiconductor material and interact with a charge-sensitive region, generating a significant amount of charge (electron-hole pairs) along their tracks. These excess charges can damage the device, and the response can range from temporary perturbations to permanent changes in the state or performance. These phenomena are called single event effects (SEE). Before application in flight systems, electronic parts need to be qualified and tested for performance and radiation sensitivity. Typically, their susceptibility to SEE is tested by exposure to an ion beam from a particle accelerator. At such facilities, the device under test (DUT) is irradiated with large beams so there is no fine resolution to investigate particular regions of sensitivity on the parts. While it is the most reliable approach for radiation qualification, these evaluations are time consuming and costly. There is always a need for new cost-efficient strategies to complement accelerator testing: pulsed lasers provide such a solution. Pulsed laser light can be utilized to simulate heavy ion effects with the advantage of being able to localize the sensitive region of an integrated circuit. Generally, a focused laser beam of approximately picosecond pulse duration is used to generate carrier density in the semiconductor device. During irradiation, the laser pulse is absorbed by the electronic medium with a wavelength selected accordingly by the user, and the laser energy can ionize and simulate SEE as would occur in space. With a tightly focused near infrared (NIR) laser beam, the beam waist of about a micrometer can be achieved, and additional scanning techniques are able to yield submicron resolution. This feature allows mapping of all of the sensitive regions of the studied device with fine resolution, unlike heavy ion experiments. The problematic regions can be precisely identified, and it provides a considerable amount of information about the circuit. In addition, the system allows flexibility for testing the device in different configurations in situ.

  14. A High-Average-Power Free Electron Laser for Microfabrication and Surface Applications

    NASA Technical Reports Server (NTRS)

    Dylla, H. F.; Benson, S.; Bisognano, J.; Bohn, C. L.; Cardman, L.; Engwall, D.; Fugitt, J.; Jordan, K.; Kehne, D.; Li, Z.; hide

    1995-01-01

    CEBAF has developed a comprehensive conceptual design of an industrial user facility based on a kilowatt ultraviolet (UV) (160-1000 mm) and infrared (IR) (2-25 micron) free electron laser (FEL) driven by a recirculating, energy recovering 200 MeV superconducting radio frequency (SRF) accelerator. FEL users, CEBAF's partners in the Lase Processing Consortium, including AT&T, DuPont, IBM, Northrop Grumman, 3M, and Xerox, are developing applications such as metal, ceramic, and electronic material micro-fabrication and polymer and metal surface processing, with the overall effort leading to later scale-up to industrial systems at 50-100 kW. Representative applications are described. The proposed high-average-power FEL overcomes limitations of conventional laser sources in available power, cost-effectiveness, tunability, and pulse structure.

  15. Projected quasiparticle theory for molecular electronic structure

    NASA Astrophysics Data System (ADS)

    Scuseria, Gustavo E.; Jiménez-Hoyos, Carlos A.; Henderson, Thomas M.; Samanta, Kousik; Ellis, Jason K.

    2011-09-01

    We derive and implement symmetry-projected Hartree-Fock-Bogoliubov (HFB) equations and apply them to the molecular electronic structure problem. All symmetries (particle number, spin, spatial, and complex conjugation) are deliberately broken and restored in a self-consistent variation-after-projection approach. We show that the resulting method yields a comprehensive black-box treatment of static correlations with effective one-electron (mean-field) computational cost. The ensuing wave function is of multireference character and permeates the entire Hilbert space of the problem. The energy expression is different from regular HFB theory but remains a functional of an independent quasiparticle density matrix. All reduced density matrices are expressible as an integration of transition density matrices over a gauge grid. We present several proof-of-principle examples demonstrating the compelling power of projected quasiparticle theory for quantum chemistry.

  16. Are low income patients receiving the benefits of electronic health records? A statewide survey.

    PubMed

    Butler, Matthew J; Harootunian, Gevork; Johnson, William G

    2013-06-01

    There are concerns that physicians serving low-income, Medicaid patients, in the United States are less likely to adopt electronic health records and, if so, that Medicaid patients will be denied the benefits from electronic health record use. This study seeks to determine whether physicians treating Medicaid patients were less likely to have adopted electronic health records. Physician surveys completed during physicians' license renewal process in Arizona were merged with the physician licensing data and Medicaid administrative claims data. Survey responses were received from 50.7 percent (6,780 out of 13,380) of all physicians practicing in Arizona. Physician survey responses were used to identify whether the physician used electronic health records and the degree to which the physician exchanged electronic health records with other health-care providers. Medicaid claims data were used to identify which physicians provided health care to Medicaid beneficiaries. The primary outcome of interest was whether Medicaid providers were more or less likely to have adopted electronic health records. Logistic regression analysis was used to estimate average marginal effects. In multivariate analysis, physicians with 20 or more Medicaid patients during the survey cycle were 4.1 percent more likely to use an electronic health record and 5.2 percent more likely to be able to transmit electronic health records to at least one health-care provider outside of their practice. These effects increase in magnitude when the analysis is restricted to solo practice physicians This is the first study to find a pro-Medicaid gap in electronic health record adoption suggesting that the low income patients served by Arizona's Health Care Cost Containment System are not at a disadvantage with regard to electronic health record access and that Arizona's model of promoting electronic health record adoption merits further study.

  17. Pilot production system cost/benefit analysis: Digital document storage project

    NASA Technical Reports Server (NTRS)

    1989-01-01

    The Digital Document Storage (DDS)/Pilot Production System (PPS) will provide cost effective electronic document storage, retrieval, hard copy reproduction, and remote access for users of NASA Technical Reports. The DDS/PPS will result in major benefits, such as improved document reproduction quality within a shorter time frame than is currently possible. In addition, the DDS/PPS will provide an important strategic value through the construction of a digital document archive. It is highly recommended that NASA proceed with the DDS Prototype System and a rapid prototyping development methodology in order to validate recent working assumptions upon which the success of the DDS/PPS is dependent.

  18. Characterization of the ETEL D784UKFLB 11 in. photomultiplier tube

    NASA Astrophysics Data System (ADS)

    Barros, N.; Kaptanoglu, T.; Kimelman, B.; Klein, J. R.; Moore, E.; Nguyen, J.; Stavreva, K.; Svoboda, R.

    2017-04-01

    Water Cherenkov and scintillator detectors are a critical tool for neutrino physics. Their large size, low threshold, and low operational cost make them excellent detectors for long baseline neutrino oscillations, proton decay, supernova and solar neutrinos, double beta decay, and ultra-high energy astrophysical neutrinos. Proposals for a new generation of large detectors rely on the availability of large format, fast, cost-effective photomultiplier tubes. The Electron Tubes Enterprises, Ltd (ETEL) D784KFLB 11 in. Photomultiplier Tube has been developed for large neutrino detectors. We have measured the timing characteristics, relative efficiency, and magnetic field sensitivity of the first fifteen prototypes.

  19. Recent advances in laser-driven neutron sources

    NASA Astrophysics Data System (ADS)

    Alejo, A.; Ahmed, H.; Green, A.; Mirfayzi, S. R.; Borghesi, M.; Kar, S.

    2016-11-01

    Due to the limited number and high cost of large-scale neutron facilities, there has been a growing interest in compact accelerator-driven sources. In this context, several potential schemes of laser-driven neutron sources are being intensively studied employing laser-accelerated electron and ion beams. In addition to the potential of delivering neutron beams with high brilliance, directionality and ultra-short burst duration, a laser-driven neutron source would offer further advantages in terms of cost-effectiveness, compactness and radiation confinement by closed-coupled experiments. Some of the recent advances in this field are discussed, showing improvements in the directionality and flux of the laser-driven neutron beams.

  20. Productivity loss due to overweight and obesity: a systematic review of indirect costs

    PubMed Central

    Goettler, Andrea; Grosse, Anna

    2017-01-01

    Objective The increasingly high levels of overweight and obesity among the workforce are accompanied by a hidden cost burden due to losses in productivity. This study reviews the extent of indirect cost of overweight and obesity. Methods A systematic search was conducted in eight electronic databases (PubMed, Cochrane Library, Web of Science Core Collection, PsychInfo, Cinahl, EconLit and ClinicalTrial.gov). Additional studies were added from reference lists of original studies and reviews. Studies were eligible if they were published between January 2000 and June 2017 and included monetary estimates of indirect costs of overweight and obesity. The authors reviewed studies independently and assessed their quality. Results Of the 3626 search results, 50 studies met the inclusion criteria. A narrative synthesis of the reviewed studies revealed substantial costs due to lost productivity among workers with obesity. Especially absenteeism and presenteeism contribute to high indirect costs. However, the methodologies and results vary greatly, especially regarding the cost of overweight, which was even associated with lower indirect costs than normal weight in three studies. Conclusion The evidence predominantly confirms substantial short-term and long-term indirect costs of overweight and obesity in the absence of effective customised prevention programmes and thus demonstrates the extent of the burden of obesity beyond the healthcare sector. PMID:28982806

Top