Sample records for count rate observed

  1. Extreme Ultraviolet Explorer observations of the magnetic cataclysmic variable RE 1938-461

    NASA Technical Reports Server (NTRS)

    Warren, John K.; Vallerga, John V.; Mauche, Christopher W.; Mukai, Koji; Siegmund, Oswald H. W.

    1993-01-01

    The magnetic cataclysmic variable RE 1938-461 was observed by the Extreme Ultraviolet Explorer (EUVE) Deep Survey instrument on 1992 July 8-9 during in-orbit calibration. It was detected in the Lexan/ boron (65-190 A) band, with a quiescent count rate of 0.0062 +/- 0.0017/s, and was not detected in the aluminum/carbon (160-360 A) band. The Lexan/boron count rate is lower than the corresponding ROSAT wide-field camera Lexan/boron count rate. This is consistent with the fact that the source was in a low state during an optical observation performed just after the EUVE observation, whereas it was in an optical high state during the ROSAT observation. The quiescent count rates are consistent with a virtual cessation of accretion. Two transient events lasting about 1 hr occurred during the Lexan/boron pointing, the second at a count rate of 0.050 +/- 0.006/s. This appears to be the first detection of an EUV transient during the low state of a magnetic cataclysmic variable. We propose two possible explanations for the transient events.

  2. Alice Solar Occultation

    NASA Image and Video Library

    2015-07-17

    This figure shows how the Alice instrument count rate changed over time during the sunset and sunrise observations. The count rate is largest when the line of sight to the sun is outside of the atmosphere at the start and end times. Molecular nitrogen (N2) starts absorbing sunlight in the upper reaches of Pluto's atmosphere, decreasing as the spacecraft approaches the planet's shadow. As the occultation progresses, atmospheric methane and hydrocarbons can also absorb the sunlight and further decrease the count rate. When the spacecraft is totally in Pluto's shadow the count rate goes to zero. As the spacecraft emerges from Pluto's shadow into sunrise, the process is reversed. By plotting the observed count rate in the reverse time direction, it is seen that the atmospheres on opposite sides of Pluto are nearly identical. http://photojournal.jpl.nasa.gov/catalog/PIA19716

  3. Observation of fluctuation of gamma-ray count rate accompanying thunderstorm activity and energy spectrum of gamma rays in the atmosphere up to several kilometers altitude from the ground

    NASA Astrophysics Data System (ADS)

    Torii, T.; Sanada, Y.; Watanabe, A.

    2017-12-01

    In the vicinity of the tops of high mountains and in the coastal areas of the Sea of Japan in winter, the generation of high energy photons that lasts more than 100 seconds at the occurrence of thunderclouds has been reported. At the same time, 511 keV gamma rays are also detected. On the other hand, we irradiated a radiosonde equipped with gamma-ray detectors at the time of thunderstorm and observed fluctuation in gamma-ray count-rate. As a result, we found that the gamma-ray count-rate increases significantly near the top of the thundercloud. Therefore, in order to investigate the fluctuation of the energy of the gamma rays, we developed a radiation detector for radiosonde to observe the fluctuation of the low energy gamma-ray spectrum and observed the fluctuation of the gamma-ray spectrum. We will describe the counting rate and spectral fluctuation of gamma-ray detectors for radiosonde observed in the sky in Fukushima prefecture, Japan.

  4. Point count length and detection of forest neotropical migrant birds

    USGS Publications Warehouse

    Dawson, D.K.; Smith, D.R.; Robbins, C.S.; Ralph, C. John; Sauer, John R.; Droege, Sam

    1995-01-01

    Comparisons of bird abundances among years or among habitats assume that the rates at which birds are detected and counted are constant within species. We use point count data collected in forests of the Mid-Atlantic states to estimate detection probabilities for Neotropical migrant bird species as a function of count length. For some species, significant differences existed among years or observers in both the probability of detecting the species and in the rate at which individuals are counted. We demonstrate the consequence that variability in species' detection probabilities can have on estimates of population change, and discuss ways for reducing this source of bias in point count studies.

  5. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    One of the most valuable unique characteristics of the PCA is the high count rates (100,000 c/s) it can record, and the resulting extreme sensitivity to weak variability. Only few sources get this bright. Our Cycle-1 work on Sco X-1 has shown that performing high count rate observations is very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black-hole transient (if any) will reach 100,000 c/s levels. When this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state-of-the-art high count rate observations covering all of the most crucial aspects of the source variability.

  6. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2-7 proposal. - The PCA is unique by the high count rates (~100,000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our RXTE work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black-hole transient (if any) will reach 10^5 c/s/5PCU levels. When this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state-of- the-art high count rate observations covering all of the most crucial aspects of the source variability.

  7. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2-8 proposal. - The PCA is unique by the high count rates (~100,000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our RXTE work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black-hole transient (if any) will reach 10^5 c/s/5PCU levels. When this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state-of- the-art high count rate observations covering all of the most crucial aspects of the source variability.

  8. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2-9 proposal. The PCA is unique by the high count rates (~100,000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our RXTE work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life og the satallire probably only one black-hole transient (if any) will reach 10^5 cps/5PCU levels. when this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state of the art high count rate observations covering all of the most crucial aspects of the source variability.

  9. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2-5 proposal. - The PCA is unique by the high count rates (~100,000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our RXTE work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black-hole transient (if any) will reach 100,000 c/s levels. When this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state-of- the-art high count rate observations covering all of the most crucial aspects of the source variability.

  10. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2&3 proposal. - The PCA is unique by the high count rates (~100,000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our Cycle 1-3 work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black-hole transient (if any) will reach 100,000 c/s levels. When this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state-of- the-art high count rate observations covering all of the most crucial aspects of the source variability.

  11. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2,3&4 proposal. - The PCA is unique by the high count rates (~100,000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our Cycle 1-3 work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black-hole transient (if any) will reach 100,000 c/s levels. When this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state-of- the-art high count rate observations covering all of the most crucial aspects of the source variability.

  12. Asm-Triggered too Observations of 100,000 C/s Black Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    RESUBMISSION ACCEPTED CYCLE 2 PROPOSAL - The PCA is unique by the high count rates (~100,000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our Cycle 1&2 work on Sco X-1 and 1744-28 has shown that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black-hole transient (if any) will reach 100,000 c/s levels. When this occurs, a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state-of- the-art high count rate observations covering all of the most crucial aspects of the source variability.

  13. ASM Triggered too Observations of 100,000 C/s Black-Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2-10 proposal. The PCA is unique by the high count rates (~100.000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our RXTE work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black hole transient (if any) will reach 10^5 cps/5 PCU levels. When this occurs a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state of the art high count rate observations covering all of the most crusial aspects of the source variability.

  14. ASM Triggered too Observations of 100,000 C/s Black-Hole Candidates (core Program)

    NASA Astrophysics Data System (ADS)

    Resubmission accepted Cycle 2-11 proposal. The PCA is unique by the high count rates (~100.000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our RXTE work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black hole transient (if any) will reach 10^5 cps/5 PCU levels. When this occurs a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state of the art high count rate observations covering all of the most crusial aspects of the source variability.

  15. ASM Triggered too Observations of 100,000 C/s Black-Hole Candidates

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    Resubmission accepted Cycle 2-11 proposal. The PCA is unique by the high count rates (~100.000 c/s) it can record, and its resulting extreme sensitivity to weak variability. Only few sources get this bright. Our RXTE work on Sco X-1 and 1744-28 shows that high count rate observations are very rewarding, but also difficult and not without risk. In the life of the satellite probably only one black hole transient (if any) will reach 10^5 cps/5 PCU levels. When this occurs a window of discovery will be opened on black holes, which will nearly certainly close again within a few days. This proposal aims at ensuring that optimal use is made of this opportunity by performing state of the art high count rate observations covering all of the most crusial aspects of the source variability.

  16. Multi-Parameter Linear Least-Squares Fitting to Poisson Data One Count at a Time

    NASA Technical Reports Server (NTRS)

    Wheaton, W.; Dunklee, A.; Jacobson, A.; Ling, J.; Mahoney, W.; Radocinski, R.

    1993-01-01

    A standard problem in gamma-ray astronomy data analysis is the decomposition of a set of observed counts, described by Poisson statistics, according to a given multi-component linear model, with underlying physical count rates or fluxes which are to be estimated from the data.

  17. Comparisons of monthly mean cosmic ray counting rates observes from worldwide network of neutron monitors

    NASA Technical Reports Server (NTRS)

    Ryu, J. Y.; Wada, M.

    1985-01-01

    In order to examine the stability of neutron monitor observation, each of the monthly average counting rates of a neutron monitors is correlated to those of Kiel neutron monitor. The regression coefficients thus obtained are compared with the coupling coefficients of isotropic intensity radiation. The results of the comparisons for five year periods during 1963 to 1982, and for whole period are given. The variation spectrum with a single power law with an exponent of -0.75 up to 50 GV is not so unsatisfactory one. More than one half of the stations show correlations with the coefficient greater than 0.9. Some stations have shifted the level of mean counting rates by changing the instrumental characteristics which can be adjusted.

  18. Modeling and simulation of count data.

    PubMed

    Plan, E L

    2014-08-13

    Count data, or number of events per time interval, are discrete data arising from repeated time to event observations. Their mean count, or piecewise constant event rate, can be evaluated by discrete probability distributions from the Poisson model family. Clinical trial data characterization often involves population count analysis. This tutorial presents the basics and diagnostics of count modeling and simulation in the context of pharmacometrics. Consideration is given to overdispersion, underdispersion, autocorrelation, and inhomogeneity.

  19. Probing Jupiter's Radiation Environment with Juno-UVS

    NASA Astrophysics Data System (ADS)

    Kammer, J.; Gladstone, R.; Greathouse, T. K.; Hue, V.; Versteeg, M. H.; Davis, M. W.; Santos-Costa, D.; Becker, H. N.; Bolton, S. J.; Connerney, J. E. P.; Levin, S.

    2017-12-01

    While primarily designed to observe photon emission from the Jovian aurora, Juno's Ultraviolet Spectrograph (Juno-UVS) has also measured background count rates associated with penetrating high-energy radiation. These background counts are distinguishable from photon events, as they are generally spread evenly across the entire array of the Juno-UVS detector, and as the spacecraft spins, they set a baseline count rate higher than the sky background rate. During eight perijove passes, this background radiation signature has varied significantly on both short (spin-modulated) timescales, as well as longer timescales ( minutes to hours). We present comparisons of the Juno-UVS data across each of the eight perijove passes, with a focus on the count rate that can be clearly attributed to radiation effects rather than photon events. Once calibrated to determine the relationship between count rate and penetrating high-energy radiation (e.g., using existing GEANT models), these in situ measurements by Juno-UVS will provide additional constraints to radiation belt models close to the planet.

  20. The effects of awareness and count duration on adult respiratory rate measurements: An experimental study.

    PubMed

    Hill, Andrew; Kelly, Eliza; Horswill, Mark S; Watson, Marcus O

    2018-02-01

    To investigate whether awareness of manual respiratory rate monitoring affects respiratory rate in adults, and whether count duration influences respiratory rate estimates. Nursing textbooks typically suggest that the patient should ideally be unaware of respiratory rate observations; however, there is little published evidence of the effect of awareness on respiratory rate, and none specific to manual measurement. In addition, recommendations about the length of the respiratory rate count vary from text to text, and the relevant empirical evidence is scant, inconsistent and subject to substantial methodological limitations. Experimental study with awareness of respiration monitoring (aware, unaware; randomised between-subjects) and count duration (60 s, 30 s, 15 s; within-subjects) as the independent variables. Respiratory rate (breaths/minute) was the dependent variable. Eighty-two adult volunteers were randomly assigned to aware and unaware conditions. In the baseline block, no live monitoring occurred. In the subsequent experimental block, the researcher informed aware participants that their respiratory rate would be counted, and did so. Respirations were captured throughout via video recording, and counted by blind raters viewing 60-, 30- and 15-s extracts. The data were collected in 2015. There was no baseline difference between the groups. During the experimental block, the respiratory rates of participants in the aware condition were an average of 2.13 breaths/minute lower compared to unaware participants. Reducing the count duration from 1 min to 15 s caused respiratory rate to be underestimated by an average of 2.19 breaths/minute (and 0.95 breaths/minute for 30-s counts). The awareness effect did not depend on count duration. Awareness of monitoring appears to reduce respiratory rate, and shorter monitoring durations yield systematically lower respiratory rate estimates. When interpreting and acting upon respiratory rate data, clinicians should consider the potential influence of these factors, including cumulative effects. © 2017 The Authors. Journal of Clinical Nursing Published by John Wiley & Sons Ltd.

  1. Phase space representation of neutron monitor count rate and atmospheric electric field in relation to solar activity in cycles 21 and 22.

    PubMed

    Silva, H G; Lopes, I

    Heliospheric modulation of galactic cosmic rays links solar cycle activity with neutron monitor count rate on earth. A less direct relation holds between neutron monitor count rate and atmospheric electric field because different atmospheric processes, including fluctuations in the ionosphere, are involved. Although a full quantitative model is still lacking, this link is supported by solid statistical evidence. Thus, a connection between the solar cycle activity and atmospheric electric field is expected. To gain a deeper insight into these relations, sunspot area (NOAA, USA), neutron monitor count rate (Climax, Colorado, USA), and atmospheric electric field (Lisbon, Portugal) are presented here in a phase space representation. The period considered covers two solar cycles (21, 22) and extends from 1978 to 1990. Two solar maxima were observed in this dataset, one in 1979 and another in 1989, as well as one solar minimum in 1986. Two main observations of the present study were: (1) similar short-term topological features of the phase space representations of the three variables, (2) a long-term phase space radius synchronization between the solar cycle activity, neutron monitor count rate, and potential gradient (confirmed by absolute correlation values above ~0.8). Finally, the methodology proposed here can be used for obtaining the relations between other atmospheric parameters (e.g., solar radiation) and solar cycle activity.

  2. X-ray detection of Nova Del 2013 with Swift

    NASA Astrophysics Data System (ADS)

    Castro-Tirado, Alberto J.; Martin-Carrillo, Antonio; Hanlon, Lorraine

    2013-08-01

    Continuous X-ray monitoring by Swift of Nova Del 2013 (see CBET #3628) shows an increase of X-ray emission at the source location compared to previous observations (ATEL #5283, ATEL #5305) during a 3.9 ksec observation at UT 2013-08-22 12:05. With the XRT instrument operating in window timing mode, 744 counts were extracted from a 50 pixel long source region and 324 counts from a similar box for a background region, resulting in a 13-sigma detection with a net count rate of 0.11±0.008 counts/sec.

  3. A Prescription for List-Mode Data Processing Conventions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beddingfield, David H.; Swinhoe, Martyn Thomas; Huszti, Jozsef

    There are a variety of algorithmic approaches available to process list-mode pulse streams to produce multiplicity histograms for subsequent analysis. In the development of the INCC v6.0 code to include the processing of this data format, we have noted inconsistencies in the “processed time” between the various approaches. The processed time, tp, is the time interval over which the recorded pulses are analyzed to construct multiplicity histograms. This is the time interval that is used to convert measured counts into count rates. The observed inconsistencies in tp impact the reported count rate information and the determination of the error-values associatedmore » with the derived singles, doubles, and triples counting rates. This issue is particularly important in low count-rate environments. In this report we will present a prescription for the processing of list-mode counting data that produces values that are both correct and consistent with traditional shift-register technologies. It is our objective to define conventions for list mode data processing to ensure that the results are physically valid and numerically aligned with the results from shift-register electronics.« less

  4. Investigating the Extraordinary X-Ray Variability of the Infrared Quasar IRAS 13349+2439

    NASA Technical Reports Server (NTRS)

    Leighly, Karen M.

    1999-01-01

    We observed the luminous quasar IRAS 13349+2439 using RXTE (X Ray Timing Explorer) in order to search for rapid variability. Unfortunately, the source was in a low state during the observation (PCA count rate approximately 1 - 2 counts/s). It was therefore somewhat weak for RXTE and detailed analysis proved to be difficult.

  5. A strong X-ray Flare in 1ES 1959+650

    NASA Astrophysics Data System (ADS)

    Kapanadze, Bidzina

    2016-06-01

    The nearby TeV-detected HBL object 1ES 1959+650 (z=0.047) has been observed by Swift today which revealed a strong X-ray flare in the source. Namely, the observation-binned 0.3-10 keV count rate is 16.49+/-0.15 cts/s that is by a factor 2.45 larger compared to weighted mean count rate from all Swift-XRT pointings to this source, and by 90% larger than the rate recorded during the previous observation (performed on June 4). Note that the higher brightness states were observed only three times in the past (in 2015 September - December; see Kapanadze B. et al. 2016, "A recent strong X-ray flaring activity of 1ES 1959+650 with possibly less efficient stochastic acceleration", MNRASL, in press).

  6. Background Conditions for the October 29, 2003 Solar Flare by the AVS-F Apparatus Data

    NASA Astrophysics Data System (ADS)

    Arkhangelskaja, I. V.; Arkhangelskiy, A. I.; Lyapin, A. R.; Troitskaya, E. V.

    The background model for AVS-F apparatus onboard CORONAS-F satellite for the October 29, 2003 X10-class solar flare is discussed in the presented work. This background model developed for AVS-F counts rate in the low- and high-energy spectral ranges in both individual channels and summarized. Count rate were approximated by polynomials of high order taking into account the mean count rate in the geomagnetic equatorial region at the different orbits parts and Kp-index averaged on 5 bins in time interval from -24 to -12 hours before the time of geomagnetic equator passing. The observed averaged counts rate on equator in the region of geomagnetic latitude ±5o and estimated minimum count rate values are in coincidence within statistical errors for all selected orbits parts used for background modeling. This model will used to refine the estimated energy of registered during the solar flare spectral features and detailed analysis of their temporal profiles behavior both in corresponding energy bands and in summarized energy range.

  7. Fast radio burst event rate counts - I. Interpreting the observations

    NASA Astrophysics Data System (ADS)

    Macquart, J.-P.; Ekers, R. D.

    2018-02-01

    The fluence distribution of the fast radio burst (FRB) population (the `source count' distribution, N (>F) ∝Fα), is a crucial diagnostic of its distance distribution, and hence the progenitor evolutionary history. We critically reanalyse current estimates of the FRB source count distribution. We demonstrate that the Lorimer burst (FRB 010724) is subject to discovery bias, and should be excluded from all statistical studies of the population. We re-examine the evidence for flat, α > -1, source count estimates based on the ratio of single-beam to multiple-beam detections with the Parkes multibeam receiver, and show that current data imply only a very weak constraint of α ≲ -1.3. A maximum-likelihood analysis applied to the portion of the Parkes FRB population detected above the observational completeness fluence of 2 Jy ms yields α = -2.6_{-1.3}^{+0.7 }. Uncertainties in the location of each FRB within the Parkes beam render estimates of the Parkes event rate uncertain in both normalizing survey area and the estimated post-beam-corrected completeness fluence; this uncertainty needs to be accounted for when comparing the event rate against event rates measured at other telescopes.

  8. Cerebellar pathology in childhood-onset vs. adult-onset essential tremor.

    PubMed

    Louis, Elan D; Kuo, Sheng-Han; Tate, William J; Kelly, Geoffrey C; Faust, Phyllis L

    2017-10-17

    Although the incidence of ET increases with advancing age, the disease may begin at any age, including childhood. The question arises as to whether childhood-onset ET cases manifest the same sets of pathological changes in the cerebellum as those whose onset is during adult life. We quantified a broad range of postmortem features (Purkinje cell [PC] counts, PC axonal torpedoes, a host of associated axonal changes [PC axonal recurrent collateral count, PC thickened axonal profile count, PC axonal branching count], heterotopic PCs, and basket cell rating) in 60 ET cases (11 childhood-onset and 49 adult-onset) and 30 controls. Compared to controls, childhood-onset ET cases had lower PC counts, higher torpedo counts, higher heterotopic PC counts, higher basket cell plexus rating, and marginally higher PC axonal recurrent collateral counts. The median PC thickened axonal profile count and median PC axonal branching count were two to five times higher in childhood-onset ET than controls, but the differences did not reach statistical significance. Childhood-onset and adult-onset ET had similar PC counts, torpedo counts, heterotopic PC counts, basket cell plexus rating, PC axonal recurrent collateral counts, PC thickened axonal profile count and PC axonal branching count. In conclusion, we found that childhood-onset and adult-onset ET shared similar pathological changes in the cerebellum. The data suggest that pathological changes we have observed in the cerebellum in ET are a part of the pathophysiological cascade of events in both forms of the disease and that both groups seem to reach the same pathological endpoints at a similar age of death. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. 500-MHz x-ray counting with a Si-APD and a fast-pulse processing system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kishimoto, Shunji; Taniguchi, Takashi; Tanaka, Manobu

    2010-06-23

    We introduce a counting system of up to 500 MHz for synchrotron x-ray high-rate measurements. A silicon avalanche photodiode detector was used in the counting system. The fast-pulse circuit of the amplifier was designed with hybrid ICs to prepare an ASIC system for a large-scale pixel array detector in near future. The fast amplifier consists of two cascading emitter-followers using 10-GHz band transistors. A count-rate of 3.25x10{sup 8} s{sup -1} was then achieved using the system for 8-keV x-rays. However, a baseline shift by adopting AC-coupling in the amplifier disturbed us to observe the maximum count of 4.49x10{sup 8} s{supmore » -1}, determined by electron-bunch filling into a ring accelerator. We also report that an amplifier with a baseline restorer was tested in order to keep the baseline level to be 0 V even at high input rates.« less

  10. Performance evaluation of the Ingenuity TF PET/CT scanner with a focus on high count-rate conditions

    NASA Astrophysics Data System (ADS)

    Kolthammer, Jeffrey A.; Su, Kuan-Hao; Grover, Anu; Narayanan, Manoj; Jordan, David W.; Muzic, Raymond F.

    2014-07-01

    This study evaluated the positron emission tomography (PET) imaging performance of the Ingenuity TF 128 PET/computed tomography (CT) scanner which has a PET component that was designed to support a wider radioactivity range than is possible with those of Gemini TF PET/CT and Ingenuity TF PET/MR. Spatial resolution, sensitivity, count rate characteristics and image quality were evaluated according to the NEMA NU 2-2007 standard and ACR phantom accreditation procedures; these were supplemented by additional measurements intended to characterize the system under conditions that would be encountered during quantitative cardiac imaging with 82Rb. Image quality was evaluated using a hot spheres phantom, and various contrast recovery and noise measurements were made from replicated images. Timing and energy resolution, dead time, and the linearity of the image activity concentration, were all measured over a wide range of count rates. Spatial resolution (4.8-5.1 mm FWHM), sensitivity (7.3 cps kBq-1), peak noise-equivalent count rate (124 kcps), and peak trues rate (365 kcps) were similar to those of the Gemini TF PET/CT. Contrast recovery was higher with a 2 mm, body-detail reconstruction than with a 4 mm, body reconstruction, although the precision was reduced. The noise equivalent count rate peak was broad (within 10% of peak from 241-609 MBq). The activity measured in phantom images was within 10% of the true activity for count rates up to those observed in 82Rb cardiac PET studies.

  11. RXTE/PCA and Swift/XRT observations of GRO J1655-40 during decay

    NASA Astrophysics Data System (ADS)

    Homan, Jeroen; Kong, Albert; Tomsick, John; Miller, Jon; Campana, Sergio; Wijnands, Rudy; Belloni, Tomaso; Lewin, Walter

    2005-10-01

    Following its transition to the hard state (ATels #607,#612), we have continued our daily RXTE/PCA observations of the black hole X-ray transient GRO J1655-40 (see http://tahti.mit.edu/opensource/1655). Between September 23, when the source reached the hard state, and October 10, the RXTE/ PCA count rate decreased exponentially, with an e-folding time of ~7 days. After October 10 the decrease started to slow down and data from the last few days suggest that the count rate may have reached a constant level.

  12. Death rates in HIV-positive antiretroviral-naive patients with CD4 count greater than 350 cells per microL in Europe and North America: a pooled cohort observational study

    PubMed Central

    2011-01-01

    Background It is unclear whether antiretroviral (ART) naive HIV-positive individuals with high CD4 counts have a raised mortality risk compared with the general population, but this is relevant for considering earlier initiation of antiretroviral therapy. Methods Pooling data from 23 European and North American cohorts, we calculated country-, age-, sex-, and year-standardised mortality ratios (SMRs), stratifying by risk group. Included patients had at least one pre-ART CD4 count above 350 cells/mm3. The association between CD4 count and death rate was evaluated using Poisson regression methods. Findings Of 40,830 patients contributing 80,682 person-years of follow up with CD4 count above 350 cells/mm3, 419 (1.0%) died. The SMRs (95% confidence interval) were 1.30 (1.06-1.58) in homosexual men, and 2.94 (2.28-3.73) and 9.37 (8.13-10.75) in the heterosexual and IDU risk groups respectively. CD4 count above 500 cells/mm3 was associated with a lower death rate than 350-499 cells/mm3: adjusted rate ratios (95% confidence intervals) for 500-699 cells/mm3 and above 700 cells/mm3 were 0.77 (0.61-0.95) and 0.66 (0.52-0.85) respectively. Interpretation In HIV-infected ART-naive patients with high CD4 counts, death rates were raised compared with the general population. In homosexual men this was modest, suggesting that a proportion of the increased risk in other groups is due to confounding by other factors. Even in this high CD4 count range, lower CD4 count was associated with raised mortality. PMID:20638118

  13. Sperm count as a surrogate endpoint for male fertility control.

    PubMed

    Benda, Norbert; Gerlinger, Christoph

    2007-11-30

    When assessing the effectiveness of a hormonal method of fertility control in men, the classical approach used for the assessment of hormonal contraceptives in women, by estimating the pregnancy rate or using a life-table analysis for the time to pregnancy, is difficult to apply in a clinical development program. The main reasons are the dissociation of the treated unit, i.e. the man, and the observed unit, i.e. his female partner, the high variability in the frequency of male intercourse, the logistical cost and ethical concerns related to the monitoring of the trial. A reasonable surrogate endpoint of the definite endpoint time to pregnancy is sperm count. In addition to the avoidance of the mentioned problems, trials that compare different treatments are possible with reasonable sample sizes, and study duration can be shorter. However, current products do not suppress sperm production to 100 per cent in all men and the sperm count is only observed with measurement error. Complete azoospermia might not be necessary in order to achieve an acceptable failure rate compared with other forms of male fertility control. Therefore, the use of sperm count as a surrogate endpoint must rely on the results of a previous trial in which both the definitive- and surrogate-endpoint results were assessed. The paper discusses different estimation functions of the mean pregnancy rate (corresponding to the cumulative hazard) that are based on the results of sperm count trial and a previous trial in which both sperm count and time to pregnancy were assessed, as well as the underlying assumptions. Sample size estimations are given for pregnancy rate estimation with a given precision.

  14. Linking reproduction and survival can improve model estimates of vital rates derived from limited time-series counts of pinnipeds and other species.

    PubMed

    Battaile, Brian C; Trites, Andrew W

    2013-01-01

    We propose a method to model the physiological link between somatic survival and reproductive output that reduces the number of parameters that need to be estimated by models designed to determine combinations of birth and death rates that produce historic counts of animal populations. We applied our Reproduction and Somatic Survival Linked (RSSL) method to the population counts of three species of North Pacific pinnipeds (harbor seals, Phoca vitulina richardii (Gray, 1864); northern fur seals, Callorhinus ursinus (L., 1758); and Steller sea lions, Eumetopias jubatus (Schreber, 1776))--and found our model outperformed traditional models when fitting vital rates to common types of limited datasets, such as those from counts of pups and adults. However, our model did not perform as well when these basic counts of animals were augmented with additional observations of ratios of juveniles to total non-pups. In this case, the failure of the ratios to improve model performance may indicate that the relationship between survival and reproduction is redefined or disassociated as populations change over time or that the ratio of juveniles to total non-pups is not a meaningful index of vital rates. Overall, our RSSL models show advantages to linking survival and reproduction within models to estimate the vital rates of pinnipeds and other species that have limited time-series of counts.

  15. Cold blobs of protons in Jupiter's outer magnetosphere as observed by Juno's JADE

    NASA Astrophysics Data System (ADS)

    Wilson, R. J.; Bagenal, F.; Valek, P. W.; Allegrini, F.; Angold, N. G.; Chae, K.; Ebert, R. W.; Kim, T. K. H.; Loeffler, C.; Louarn, P.; McComas, D. J.; Pollock, C. J.; Ranquist, D. A.; Reno, C.; Szalay, J. R.; Thomsen, M. F.; Weidner, S.; Bolton, S. J.; Levin, S.

    2017-12-01

    Juno's 53-day polar orbits cut through the equatorial plane when inbound to perijove. The JADE instrument has been observing thermal ions (0.01-50 keV/q) and electrons (0.1-100 keV/q) in these regions since Orbit 05. Even at distances greater than 70 RJ, magnetodisk crossings are clear with high count rates measured before returning to rarified plasma conditions outside the disk. However JADE's detectors observes regions of slightly greater ion counts that last for about an hour. The ion counts are too low to analyze at the typical 30s or 60s low rate instrument cadence, but by summing to 10-minute resolution the features become analyzable. We find these regions are populated with protons with higher density than those typically observed outside the magnetodisk, and that they are colder than the ambient plasma. Reanalysis of Voyager data (DOI: 10.1002/2017JA024053) also showed cold dense blobs of plasma in the inner to middle magnetosphere, however these were of heavier ion species, short lived (several minutes) and within 40 RJ of Jupiter. This presentation will investigate the JADE identified cold blobs observed to date and compare with those observed with Voyager.

  16. Effects of high CD4 cell counts on death and attrition among HIV patients receiving antiretroviral treatment: an observational cohort study.

    PubMed

    Tang, Zhenzhu; Pan, Stephen W; Ruan, Yuhua; Liu, Xuanhua; Su, Jinming; Zhu, Qiuying; Shen, Zhiyong; Zhang, Heng; Chen, Yi; Lan, Guanghua; Xing, Hui; Liao, Lingjie; Feng, Yi; Shao, Yiming

    2017-06-09

    Current WHO guidelines recommend initiating ART regardless of CD4+ cell count. In response, we conducted an observational cohort study to assess the effects of pre-ART CD4+ cell count levels on death, attrition, and death or attrition in HIV treated patients. This large HIV treatment cohort study (n = 49,155) from 2010 to 2015 was conducted in Guangxi, China. We used a Cox regression model to analyze associations between pre-ART CD4+ cell counts and death, attrition, and death or attrition. The average mortality and ART attrition rates among all treated patients were 2.63 deaths and 5.32 attritions per 100 person-years, respectively. Compared to HIV patients with <350 CD4+ cells/mm 3 at ART initiation, HIV patients with >500 CD4+ cells/mm 3 at ART initiation had a significantly lower mortality rate (Adjusted hazard ratio: 0.56, 95% CI: 0.40-0.79), but significantly higher ART attrition rate (AHR: 1.17, 95% CI: 1.03-1.33). Results from this study suggest that HIV patients with high CD4+ cell counts at the time of ART initiation may be at greater risk of treatment attrition. To further reduce ART attrition, it is imperative that patient education and healthcare provider training on ART adherence be enhanced and account for CD4 levels at ART initiation.

  17. Current automated 3D cell detection methods are not a suitable replacement for manual stereologic cell counting

    PubMed Central

    Schmitz, Christoph; Eastwood, Brian S.; Tappan, Susan J.; Glaser, Jack R.; Peterson, Daniel A.; Hof, Patrick R.

    2014-01-01

    Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D) stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D) “cell counting” approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38 and 99% and false-positive rates from 3.6 to 82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections. PMID:24847213

  18. Defecation rate in captive European bison, Bison bonasus.

    PubMed

    Eycott, Amy; Daleszczyk, Katarzyna; Drese, Jacqueline; Cantero, Adrià Solé; Pèbre, Jennifer; Gladys, Samuel

    2013-01-01

    Data on the digestive characteristics of European bison, Bison bonasus (L.), are needed for studies of their role as the largest extant herbivore in Europe and a potential keystone species of the temperate forest ecosystem. Very little published data are available, particularly on the defecation rate which affects population estimates from dropping counts and also the individual seed deposition rate. We gathered data from a captive bison group kept at the Show Reserve of the Białowieża National Park. Droppings accumulated in the enclosure over a 72-h period were counted in winter 2010. In addition, the group was observed over approximately 6-h periods three times in winter and 16 times in summer. The count of accumulated droppings over a 72-h period gave eight defecations per day. The summer direct observations recorded 7.5 defecations per day and winter observation 5.4 defecations per day. These estimates are within the range for other bovids of similar size. The difference between summer and winter observation-based estimates may be accounted for by a higher frequency of defecation in early morning and late afternoon, periods not covered in winter observations. Given the published density of seedlings emerging from droppings of the ∼470 free-living bison in the nearby forest, eight defecations a day mean that seed deposition by European bison may contribute significantly to realize seed dispersal and plant establishment.

  19. Heart rate and leukocytes after air and ground transportation in artificially ventilated neonates: a prospective observational study.

    PubMed

    Grosek, Stefan; Mlakar, Gorazd; Vidmar, Ivan; Ihan, Alojz; Primozic, Janez

    2009-01-01

    To evaluate the effect of interhospital air and ground transportation of artificially ventilated neonates on heart rate and peripheral blood leukocyte counts. Prospective, observational study. Level III multidisciplinary Neonatal and Pediatric Intensive Care Unit. Fifty-eight near-term artificially ventilated transported neonates between May 2006 and April 2007. Day-helicopter, day- and night-ground transportation. Heart rate at retrieval, on admission to the ICU and 1 h later, and peripheral blood leukocyte counts on admission and 1 d later were compared. Fifteen neonates were transported by helicopter during the daytime (D-HEL), 20 by daytime ground and 23 by nighttime ground transportation (D-GROUND, N-GROUND). No differences in delivery mode, birth weight, gestational age, gender, primary diagnoses for transportation, response time and duration of transportation were found between the groups. Similarly, no differences in pH, pCO(2), blood pressure and skin temperature at retrieval and on admission to the ICU were found between the three groups. The mean heart rate at retrieval did not differ significantly, while on arrival in the ICU and 1 h later the D-GROUND group of patients showed a significantly higher mean heart rate compared to the D-HEL and N-GROUND groups. Moreover, leukocyte counts on arrival in the ICU showed significantly higher leukocyte counts in the D-GROUND group of patients compared to the D-HEL group of patients. These results demonstrate that there is an association between daytime ground transportation and higher heart rate and peripheral blood leukocytes.

  20. A Calibration of NICMOS Camera 2 for Low Count Rates

    NASA Astrophysics Data System (ADS)

    Rubin, D.; Aldering, G.; Amanullah, R.; Barbary, K.; Dawson, K. S.; Deustua, S.; Faccioli, L.; Fadeyev, V.; Fakhouri, H. K.; Fruchter, A. S.; Gladders, M. D.; de Jong, R. S.; Koekemoer, A.; Krechmer, E.; Lidman, C.; Meyers, J.; Nordin, J.; Perlmutter, S.; Ripoche, P.; Schlegel, D. J.; Spadafora, A.; Suzuki, N.

    2015-05-01

    NICMOS 2 observations are crucial for constraining distances to most of the existing sample of z\\gt 1 SNe Ia. Unlike conventional calibration programs, these observations involve long exposure times and low count rates. Reciprocity failure is known to exist in HgCdTe devices and a correction for this effect has already been implemented for high and medium count rates. However, observations at faint count rates rely on extrapolations. Here instead, we provide a new zero-point calibration directly applicable to faint sources. This is obtained via inter-calibration of NIC2 F110W/F160W with the Wide Field Camera 3 (WFC3) in the low count-rate regime using z∼ 1 elliptical galaxies as tertiary calibrators. These objects have relatively simple near-IR spectral energy distributions, uniform colors, and their extended nature gives a superior signal-to-noise ratio at the same count rate than would stars. The use of extended objects also allows greater tolerances on point-spread function profiles. We find space telescope magnitude zero points (after the installation of the NICMOS cooling system, NCS) of 25.296\\+/- 0.022 for F110W and 25.803\\+/- 0.023 for F160W, both in agreement with the calibration extrapolated from count rates ≳1000 times larger (25.262 and 25.799). Before the installation of the NCS, we find 24.843\\+/- 0.025 for F110W and 25.498\\+/- 0.021 for F160W, also in agreement with the high-count-rate calibration (24.815 and 25.470). We also check the standard bandpasses of WFC3 and NICMOS 2 using a range of stars and galaxies at different colors and find mild tension for WFC3, limiting the accuracy of the zero points. To avoid human bias, our cross-calibration was “blinded” in that the fitted zero-point differences were hidden until the analysis was finalized. Based on observations with the NASA/ESA Hubble Space Telescope, obtained at the Space Telescope Science Institute, which is operated by AURA, Inc., under NASA contract NAS 5-26555, under programs SM2/NIC-7049, SM2/NIC-7152, CAL/NIC-7607, CAL/NIC-7691, CAL/NIC-7693, GO-7887, CAL/NIC-7902, CAL/NIC-7904, GO/DD-7941, SM3/NIC-8983, SM3/NIC-8986, GTO/ACS-9290, ENG/NIC-9324, CAL/NIC-9325, GO-9352, GO-9375, SNAP-9485, CAL/NIC-9639, GO-9717, GO-9834, GO-9856, CAL/NIC-9995, CAL/NIC-9997, GO-10189, GO-10258, CAL/NIC-10381, CAL/NIC-10454, GO-10496, CAL/NIC-10725, CAL/NIC-10726, GO-10886, CAL/NIC-11060, CAL/NIC-11061, GO-11135, GO-11143, GO-11202, CAL/NIC-11319, GO/DD-11359, SM4/WFC3-11439, SM4/WFC3-11451, GO-11557, GO-11591, GO-11600, GO/DD-11799, CAL/WFC3-11921, CAL/WFC3-11926, GO/DD-12051, GO-12061, GO-12062, GO-12177, CAL/WFC3-12333, CAL/WFC3-12334, CAL/WFC3-12341, GO-12443, GO-12444, GO-12445, CAL/WFC3-12698, CAL/WFC3-12699, GO-12874, CAL/WFC3-13088, and CAL/WFC3-13089.

  1. Point counts from clustered populations: Lessons from an experiment with Hawaiian crows

    USGS Publications Warehouse

    Hayward, G.D.; Kepler, C.B.; Scott, J.M.

    1991-01-01

    We designed an experiment to identify factors contributing most to error in counts of Hawaiian Crow or Alala (Corvus hawaiiensis) groups that are detected aurally. Seven observers failed to detect calling Alala on 197 of 361 3-min point counts on four transects extending from cages with captive Alala. A detection curve describing the relation between frequency of flock detection and distance typified the distribution expected in transect or point counts. Failure to detect calling Alala was affected most by distance, observer, and Alala calling frequency. The number of individual Alala calling was not important in detection rate. Estimates of the number of Alala calling (flock size) were biased and imprecise: average difference between number of Alala calling and number heard was 3.24 (.+-. 0.277). Distance, observer, number of Alala calling, and Alala calling frequency all contributed to errors in estimates of group size (P < 0.0001). Multiple regression suggested that number of Alala calling contributed most to errors. These results suggest that well-designed point counts may be used to estimate the number of Alala flocks but cast doubt on attempts to estimate flock size when individuals are counted aurally.

  2. Changing mortality risk associated with CD4 cell response to antiretroviral therapy in South Africa

    PubMed Central

    Lawn, Stephen D.; Little, Francesca; Bekker, Linda-Gail; Kaplan, Richard; Campbel, Elizabeth; Orrell, Catherine; Wood, Robin

    2013-01-01

    Objective To determine the relationship between mortality risk and the CD4 cell response to antiretroviral therapy (ART). Design Observational community-based ART cohort in South Africa. Methods CD4 cell counts were measured 4 monthly, and deaths were prospectively ascertained. Cumulative person-time accrued within a range of updated CD4 cell count strata (CD4 cell-strata) was calculated and used to derive CD4 cell-stratified mortality rates. Results Patients (2423) (median baseline CD4 cell count of 105 cells/ml) were observed for up to 5 years of ART. One hundred and ninety-seven patients died during 3155 person years of observation. In multivariate analysis, mortality rate ratios associated with 0–49, 50–99, 100–199, 200–299, 300– 399, 400–499 and at least 500 cells/ml updated CD4 cell-strata were 11.6, 4.9, 2.6, 1.7, 1.5, 1.4 and 1.0, respectively. Analysis of CD4 cell count recovery permitted calculations of person-time accrued within these CD4 cell strata. Despite rapid immune recovery, high mortality in the first year of ART was related to the large proportion of person-time accrued within CD4 cell-strata less than 200 cells/ml. Moreover, patients with baseline CD4 cell counts less than 100 cells/ml had much higher cumulative mortality estimates at 1 and 4 years (11.6 and 16.7%) compared with those of patients with baseline counts of at least 100 cells/ml (5.2 and 9.5%) largely because of greater cumulative person-time at CD4 cell counts less than 200 cells/ml. Conclusion: Updated CD4 cell counts are the variable most strongly associated with mortality risk during ART. High cumulative mortality risk is associated with person-time accrued at low CD4 cell counts. National HIV programmes in resource-limited settings should be designed to minimize the time patients spend with CD4 cell counts less than 200 cells/ml both before and during ART. PMID:19114870

  3. Greater risk for viremia, immunosuppression, serious clinical events, and mortality with increasing age: the US perinatal HIV epidemic in its adolescence

    PubMed Central

    Neilan, Anne M.; Karalius, Brad; Patel, Kunjal; Van Dyke, Russell B.; Abzug, Mark J.; Agwu, Allison L.; Williams, Paige L.; Purswani, Murli; Kacanek, Deborah; Oleske, James M.; Burchett, Sandra K.; Wiznia, Andrew; Chernoff, Miriam; Seage, George R.; Ciaranello, Andrea L.

    2017-01-01

    Importance As perinatally HIV-infected youth (PHIVY) in the US grow older and more treatment-experienced, clinicians need updated information about the impact of age, CD4 count, viral load (VL), and antiretroviral drug (ARV) use on risks of opportunistic infections (OIs), key clinical events, and mortality in order to understand patient risks and improve care. Objective To determine the incidence or first occurrence during follow-up of key clinical events (including CDC-B and CDC-C events) and mortality among PHIVY stratified by age, CD4, and VL/ARV status. Design In the PHACS Adolescent Master Protocol (AMP) and IMPAACT P1074 multicenter cohort studies (2007–2015), we estimated event rates during person-time spent in key strata of age (7–12, 13–17, and 18–30 years), CD4 count (<200, 200–499, and ≥500 cells/μL), and VL/ARV status (< or ≥ 400 copies/mL; ARVs or no ARVs). Setting 41 ambulatory sites in the US, including Puerto Rico. Participants 1,562 participants in AMP and P1074 were eligible, 1446 PHIVY were included. Exposure(s) for observational studies Age, CD4 count, VL, ARV use. Main outcomes Clinical event rates stratified by person-time in age, CD4 count, and VL/ARV categories. Results During a mean follow-up of 4.9 years, higher incidences of CDC-B events, CDC-C events and mortality were observed as participants aged. Older PHIVY (13–17 and 18–30 year-olds) spent more time with VL ≥400 copies/mL and with CD4 <200/μL compared to 7–12 year-olds (30% and 44% vs. 22% of person-time with VL ≥400 copies/mL; 5% and 18% vs. 2% of person-time with CD4 <200/μL; p<0.01 for each comparison). We observed higher rates of CDC-B events, CDC-C events, bacterial infections, and mortality at lower CD4 counts, as expected. The mortality rate in older PHIVY was 6–12 times that of the general US population. Higher rates of sexually transmitted infections were also observed at lower CD4 counts, after adjusting for age. Conclusions and relevance Older PHIVY were at increased risk of viremia, immunosuppression, CDC-B events, CDC-C events, and mortality. Interventions to improve ART adherence and optimize models of care for PHIVY as they age are urgently needed to improve long-term outcomes among PHIVY. PMID:28346597

  4. Daily step count predicts acute exacerbations in a US cohort with COPD.

    PubMed

    Moy, Marilyn L; Teylan, Merilee; Weston, Nicole A; Gagnon, David R; Garshick, Eric

    2013-01-01

    COPD is characterized by variability in exercise capacity and physical activity (PA), and acute exacerbations (AEs). Little is known about the relationship between daily step count, a direct measure of PA, and the risk of AEs, including hospitalizations. In an observational cohort study of 169 persons with COPD, we directly assessed PA with the StepWatch Activity Monitor, an ankle-worn accelerometer that measures daily step count. We also assessed exercise capacity with the 6-minute walk test (6MWT) and patient-reported PA with the St. George's Respiratory Questionnaire Activity Score (SGRQ-AS). AEs and COPD-related hospitalizations were assessed and validated prospectively over a median of 16 months. Mean daily step count was 5804±3141 steps. Over 209 person-years of observation, there were 263 AEs (incidence rate 1.3±1.6 per person-year) and 116 COPD-related hospitalizations (incidence rate 0.56±1.09 per person-year). Adjusting for FEV1 % predicted and prednisone use for AE in previous year, for each 1000 fewer steps per day walked at baseline, there was an increased rate of AEs (rate ratio 1.07; 95%CI = 1.003-1.15) and COPD-related hospitalizations (rate ratio 1.24; 95%CI = 1.08-1.42). There was a significant linear trend of decreasing daily step count by quartiles and increasing rate ratios for AEs (P = 0.008) and COPD-related hospitalizations (P = 0.003). Each 30-meter decrease in 6MWT distance was associated with an increased rate ratio of 1.07 (95%CI = 1.01-1.14) for AEs and 1.18 (95%CI = 1.07-1.30) for COPD-related hospitalizations. Worsening of SGRQ-AS by 4 points was associated with an increased rate ratio of 1.05 (95%CI = 1.01-1.09) for AEs and 1.10 (95%CI = 1.02-1.17) for COPD-related hospitalizations. Lower daily step count, lower 6MWT distance, and worse SGRQ-AS predict future AEs and COPD-related hospitalizations, independent of pulmonary function and previous AE history. These results support the importance of assessing PA in patients with COPD, and provide the rationale to promote PA as part of exacerbation-prevention strategies.

  5. The Pierre Auger Observatory scaler mode for the study of solar activity modulation of galactic cosmic rays

    NASA Astrophysics Data System (ADS)

    Pierre Auger Collaboration; Abreu, P.; Aglietta, M.; Ahn, E. J.; Allard, D.; Allekotte, I.; Allen, J.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Ambrosio, M.; Aminaei, A.; Anchordoqui, L.; Andringa, S.; Antičić, T.; Anzalone, A.; Aramo, C.; Arganda, E.; Arisaka, K.; Arqueros, F.; Asorey, H.; Assis, P.; Aublin, J.; Ave, M.; Avenier, M.; Avila, G.; Bäcker, T.; Badagnani, D.; Balzer, M.; Barber, K. B.; Barbosa, A. F.; Bardenet, R.; Barroso, S. L. C.; Baughman, B.; Beatty, J. J.; Becker, B. R.; Becker, K. H.; Bellétoile, A.; Bellido, J. A.; BenZvi, S.; Berat, C.; Bergmann, T.; Bertou, X.; Biermann, P. L.; Billoir, P.; Blanco, F.; Blanco, M.; Bleve, C.; Blümer, H.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Bonino, R.; Borodai, N.; Brack, J.; Brogueira, P.; Brown, W. C.; Bruijn, R.; Buchholz, P.; Bueno, A.; Burton, R. E.; Busca, N. G.; Caballero-Mora, K. S.; Caramete, L.; Caruso, R.; Castellina, A.; Catalano, O.; Cataldi, G.; Cazon, L.; Cester, R.; Chauvin, J.; Chiavassa, A.; Chinellato, J. A.; Chou, A.; Chudoba, J.; Clay, R. W.; Colombo, E.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cook, H.; Cooper, M. J.; Coppens, J.; Cordier, A.; Cotti, U.; Coutu, S.; Covault, C. E.; Creusot, A.; Criss, A.; Cronin, J.; Curutiu, A.; Dagoret-Campagne, S.; Dallier, R.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; De Domenico, M.; De Donato, C.; de Jong, S. J.; De La Vega, G.; de Mello Junior, W. J. M.; de Mello Neto, J. R. T.; De Mitri, I.; de Souza, V.; de Vries, K. D.; Decerprit, G.; del Peral, L.; Deligny, O.; Della Selva, A.; Dembinski, H.; Denkiewicz, A.; Di Giulio, C.; Diaz, J. C.; Díaz Castro, M. L.; Diep, P. N.; Dobrigkeit, C.; D'Olivo, J. C.; Dong, P. N.; Dorofeev, A.; dos Anjos, J. C.; Dova, M. T.; D'Urso, D.; Dutan, I.; Ebr, J.; Engel, R.; Erdmann, M.; Escobar, C. O.; Etchegoyen, A.; Facal San Luis, P.; Falcke, H.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Ferguson, A. P.; Ferrero, A.; Fick, B.; Filevich, A.; Filipčič, A.; Fleck, I.; Fliescher, S.; Fracchiolla, C. E.; Fraenkel, E. D.; Fröhlich, U.; Fuchs, B.; Fulgione, W.; Gamarra, R. F.; Gambetta, S.; García, B.; García Gámez, D.; Garcia-Pinto, D.; Garrido, X.; Gascon, A.; Gelmini, G.; Gemmeke, H.; Gesterling, K.; Ghia, P. L.; Giaccari, U.; Giller, M.; Glass, H.; Gold, M. S.; Golup, G.; Gomez Albarracin, F.; Gómez Berisso, M.; Gonçalves, P.; Gonzalez, D.; Gonzalez, J. G.; Gookin, B.; Góra, D.; Gorgi, A.; Gouffon, P.; Gozzini, S. R.; Grashorn, E.; Grebe, S.; Grigat, M.; Grillo, A. F.; Guardincerri, Y.; Guarino, F.; Guedes, G. P.; Hague, J. D.; Hansen, P.; Harari, D.; Harmsma, S.; Harton, J. L.; Haungs, A.; Hebbeker, T.; Heck, D.; Herve, A. E.; Hojvat, C.; Holmes, V. C.; Homola, P.; Hórandel, J. R.; Horneffer, A.; Hrabovský, M.; Huege, T.; Insolia, A.; Ionita, F.; Italiano, A.; Jiraskova, S.; Kadija, K.; Kaducak, M.; Kampert, K. H.; Karhan, P.; Karova, T.; Kasper, P.; Kégl, B.; Keilhauer, B.; Keivani, A.; Kelley, J. L.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Knapp, J.; Koang, D.-H.; Kotera, K.; Krohm, N.; Krömer, O.; Kruppke-Hansen, D.; Kuehn, F.; Kuempel, D.; Kulbartz, J. K.; Kunka, N.; La Rosa, G.; Lachaud, C.; Lautridou, P.; Leão, M. S. A. B.; Lebrun, D.; Lebrun, P.; Leigui de Oliveira, M. A.; Lemiere, A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; López, R.; Lopez Agüera, A.; Louedec, K.; Lozano Bahilo, J.; Lucero, A.; Ludwig, M.; Lyberis, H.; Maccarone, M. C.; Macolino, C.; Maldera, S.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Marin, V.; Maris, I. C.; Marquez Falcon, H. R.; Marsella, G.; Martello, D.; Martin, L.; Martínez Bravo, O.; Mathes, H. J.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Maurizio, D.; Mazur, P. O.; Medina-Tanco, G.; Melissas, M.; Melo, D.; Menichetti, E.; Menshikov, A.; Meurer, C.; Mičanović, S.; Micheletti, M. I.; Miller, W.; Miramonti, L.; Mollerach, S.; Monasor, M.; Monnier Ragaigne, D.; Montanet, F.; Morales, B.; Morello, C.; Moreno, E.; Moreno, J. C.; Morris, C.; Mostafá, M.; Mueller, S.; Muller, M. A.; Müller, G.; Münchmeyer, M.; Mussa, R.; Navarra, G.; Navarro, J. L.; Navas, S.; Necesal, P.; Nellen, L.; Nhung, P. T.; Nierstenhoefer, N.; Nitz, D.; Nosek, D.; Nožka, L.; Nyklicek, M.; Oehlschläger, J.; Olinto, A.; Oliva, P.; Olmos-Gilbaja, V. M.; Ortiz, M.; Pacheco, N.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Palmieri, N.; Parente, G.; Parizot, E.; Parra, A.; Parrisius, J.; Parsons, R. D.; Pastor, S.; Paul, T.; Pavlidou c, V.; Payet, K.; Pech, M.; Pękala, J.; Pelayo, R.; Pepe, I. M.; Perrone, L.; Pesce, R.; Petermann, E.; Petrera, S.; Petrinca, P.; Petrolini, A.; Petrov, Y.; Petrovic, J.; Pfendner, C.; Phan, N.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Ponce, V. H.; Pontz, M.; Privitera, P.; Prouza, M.; Quel, E. J.; Rautenberg, J.; Ravel, O.; Ravignani, D.; Revenu, B.; Ridky, J.; Riggi, S.; Risse, M.; Ristori, P.; Rivera, H.; Rivière, C.; Rizi, V.; Robledo, C.; Rodriguez, G.; Rodriguez Martino, J.; Rodriguez Rojo, J.; Rodriguez-Cabo, I.; Rodríguez-Frías, M. D.; Ros, G.; Rosado, J.; Rossler, T.; Roth, M.; Rouillé-d'Orfeuil, B.; Roulet, E.; Rovero, A. C.; Salamida, F.; Salazar, H.; Salina, G.; Sánchez, F.; Santander, M.; Santo, C. E.; Santos, E.; Santos, E. M.; Sarazin, F.; Sarkar, S.; Sato, R.; Scharf, N.; Scherini, V.; Schieler, H.; Schiffer, P.; Schmidt, A.; Schmidt, F.; Schmidt, T.; Scholten, O.; Schoorlemmer, H.; Schovancova, J.; Schovánek, P.; Schroeder, F.; Schulte, S.; Schüssler, F.; Schuster, D.; Sciutto, S. J.; Scuderi, M.; Segreto, A.; Semikoz, D.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sidelnik, I.; Sigl, G.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sorokin, J.; Spinka, H.; Squartini, R.; Stapleton, J.; Stasielak, J.; Stephan, M.; Strazzeri, E.; Stutz, A.; Suarez, F.; Suomijärvi, T.; Supanitsky, A. D.; Šuša, T.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Tamashiro, A.; Tapia, A.; Tarutina, T.; Taşcǎu, O.; Tcaciuc, R.; Tcherniakhovski, D.; Tegolo, D.; Thao, N. T.; Thomas, D.; Tiffenberg, J.; Timmermans, C.; Tiwari, D. K.; Tkaczyk, W.; Todero Peixoto, C. J.; Tomé, B.; Tonachini, A.; Travnicek, P.; Tridapalli, D. B.; Tristram, G.; Trovato, E.; Tueros, M.; Ulrich, R.; Unger, M.; Urban, M.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van den Berg, A. M.; Vargas Cárdenas, B.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Venters, T.; Verzi, V.; Videla, M.; Villaseñor, L.; Wahlberg, H.; Wahrlich, P.; Wainberg, O.; Warner, D.; Watson, A. A.; Weber, M.; Weidenhaupt, K.; Weindl, A.; Westerhoff, S.; Whelan, B. J.; Wieczorek, G.; Wiencke, L.; Wilczyńska, B.; Wilczyński, H.; Will, M.; Williams, C.; Winchen, T.; Winders, L.; Winnick, M. G.; Wommer, M.; Wundheiler, B.; Yamamoto a, T.; Younk, P.; Yuan, G.; Yushkov, A.; Zamorano, B.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zaw, I.; Zepeda, A.; Ziolkowski, M.

    2011-01-01

    Since data-taking began in January 2004, the Pierre Auger Observatory has been recording the count rates of low energy secondary cosmic ray particles for the self-calibration of the ground detectors of its surface detector array. After correcting for atmospheric effects, modulations of galactic cosmic rays due to solar activity and transient events are observed. Temporal variations related with the activity of the heliosphere can be determined with high accuracy due to the high total count rates. In this study, the available data are presented together with an analysis focused on the observation of Forbush decreases, where a strong correlation with neutron monitor data is found.

  6. Pollen count and presentation of angiotensin-converting enzyme inhibitor-associated angioedema.

    PubMed

    Straka, Brittany; Nian, Hui; Sloan, Chantel; Byrd, James Brian; Woodard-Grice, Alencia; Yu, Chang; Stone, Elizabeth; Steven, Gary; Hartert, Tina; Teo, Koon K; Pare, Guillaume; McCarty, Catherine A; Brown, Nancy J

    2013-01-01

    The incidence of angiotensin-converting enzyme (ACE) inhibitor-associated angioedema is increased in patients with seasonal allergies. We tested the hypothesis that patients with ACE inhibitor-associated angioedema present during months when pollen counts are increased. Cohort analysis examined the month of presentation of ACE inhibitor-associated angioedema and pollen counts in the ambulatory and hospital setting. Patients with ACE inhibitor-associated angioedema were ascertained through (1) an observational study of patients presenting to Vanderbilt University Medical Center, (2) patients presenting to the Marshfield Clinic and participating in the Marshfield Clinic Personalized Medicine Research Project, and (3) patients enrolled in The Ongoing Telmisartan Alone and in Combination with Ramipril Global Endpoint Trial (ONTARGET). Measurements include date of presentation of ACE inhibitor-associated angioedema, population exposure to ACE inhibitor by date, and local pollen counts by date. At Vanderbilt, the rate of angioedema was significantly associated with tree pollen months (P = .01 from χ(2) test). When separate analyses were conducted in patients with a history of seasonal allergies and patients without, the rate of ACE inhibitor-associated angioedema was increased during tree pollen months only in patients with a history of seasonal allergies (P = .002). In Marshfield, the rate of angioedema was significantly associated with ragweed pollen months (P = .025). In ONTARGET, a positive trend was observed between the ACE inhibitor-associated angioedema rate and grass season, although it was not statistically significant (P = .057). Patients with ACE inhibitor-associated angioedema are more likely to present with this adverse drug event during months when pollen counts are increased. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  7. Swift J1822.3-1606: pre-outburst ROSAT limits (plus erratum)

    NASA Astrophysics Data System (ADS)

    Esposito, P.; Rea, N.; Israel, G. L.; Tieng, A.

    2011-07-01

    We report on a pre-outburst ROSAT PSPC observation of the new SGR discovered by Swift-BAT on 2011 July 14 (Cummings et al. Atel #3488). The PSPC observation was performed on 1993 September 12 for ~6.7ks. We find a source at: RA (2000) = 18 22 18.1 and Dec (2000)= -16 04 26.4, with a 5sigma detection significance. The count-rate (corrected for the PSPC PSF, sampling dead time, and vignetting) is about 0.012 counts/s.

  8. A double-observer method for reducing bias in faecal pellet surveys of forest ungulates

    USGS Publications Warehouse

    Jenkins, K.J.; Manly, B.F.J.

    2008-01-01

    1. Faecal surveys are used widely to study variations in abundance and distribution of forest-dwelling mammals when direct enumeration is not feasible. The utility of faecal indices of abundance is limited, however, by observational bias and variation in faecal disappearance rates that obscure their relationship to population size. We developed methods to reduce variability in faecal surveys and improve reliability of faecal indices. 2. We used double-observer transect sampling to estimate observational bias of faecal surveys of Roosevelt elk Cervus elaphus roosevelti and Columbian black-tailed deer Odocoileus hemionus columbianus in Olympic National Park, Washington, USA. We also modelled differences in counts of faecal groups obtained from paired cleared and uncleared transect segments as a means to adjust standing crop faecal counts for a standard accumulation interval and to reduce bias resulting from variable decay rates. 3. Estimated detection probabilities of faecal groups ranged from < 0.2-1.0 depending upon the observer, whether the faecal group was from elk or deer, faecal group size, distance of the faecal group from the sampling transect, ground vegetation cover, and the interaction between faecal group size and distance from the transect. 4. Models of plot-clearing effects indicated that standing crop counts of deer faecal groups required 34% reduction on flat terrain and 53% reduction on sloping terrain to represent faeces accumulated over a standard 100-day interval, whereas counts of elk faecal groups required 0% and 46% reductions on flat and sloping terrain, respectively. 5. Synthesis and applications. Double-observer transect sampling provides a cost-effective means of reducing observational bias and variation in faecal decay rates that obscure the interpretation of faecal indices of large mammal abundance. Given the variation we observed in observational bias of faecal surveys and persistence of faeces, we emphasize the need for future researchers to account for these comparatively manageable sources of bias before comparing faecal indices spatially or temporally. Double-observer sampling methods are readily adaptable to study variations in faecal indices of large mammals at the scale of the large forest reserve, natural area, or other forested regions when direct estimation of populations is problematic. ?? 2008 The Authors.

  9. Search for optical bursts from the gamma ray burst source GBS 0526-66

    NASA Astrophysics Data System (ADS)

    Seetha, S.; Sreenivasaiah, K. V.; Marar, T. M. K.; Kasturirangan, K.; Rao, U. R.; Bhattacharyya, J. C.

    1985-08-01

    Attempts were made to detect optical bursts from the gamma-ray burst source GBS 0526-66 during Dec. 31, 1984 to Jan. 2, 1985 and Feb. 23 to Feb. 24, 1985, using the one meter reflector of the Kavalur Observatory. Jan. 1, 1985 coincided with the zero phase of the predicted 164 day period of burst activity from the source (Rothschild and Lingenfelter, 1984). A new optical burst photon counting system with adjustable trigger threshold was used in parallel with a high speed photometer for the observations. The best time resolution was 1 ms and maximum count rate capability was 255,000 counts s(-1). Details of the instrumentation and observational results are presented.

  10. Simulation of Rate-Related (Dead-Time) Losses In Passive Neutron Multiplicity Counting Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, L.G.; Norman, P.I.; Leadbeater, T.W.

    Passive Neutron Multiplicity Counting (PNMC) based on Multiplicity Shift Register (MSR) electronics (a form of time correlation analysis) is a widely used non-destructive assay technique for quantifying spontaneously fissile materials such as Pu. At high event rates, dead-time losses perturb the count rates with the Singles, Doubles and Triples being increasingly affected. Without correction these perturbations are a major source of inaccuracy in the measured count rates and assay values derived from them. This paper presents the simulation of dead-time losses and investigates the effect of applying different dead-time models on the observed MSR data. Monte Carlo methods have beenmore » used to simulate neutron pulse trains for a variety of source intensities and with ideal detection geometry, providing an event by event record of the time distribution of neutron captures within the detection system. The action of the MSR electronics was modelled in software to analyse these pulse trains. Stored pulse trains were perturbed in software to apply the effects of dead-time according to the chosen physical process; for example, the ideal paralysable (extending) and non-paralysable models with an arbitrary dead-time parameter. Results of the simulations demonstrate the change in the observed MSR data when the system dead-time parameter is varied. In addition, the paralysable and non-paralysable models of deadtime are compared. These results form part of a larger study to evaluate existing dead-time corrections and to extend their application to correlated sources. (authors)« less

  11. Low noise and conductively cooled microchannel plates

    NASA Technical Reports Server (NTRS)

    Feller, W. B.

    1990-01-01

    Microchannel plate (MCP) dynamic range has recently been enhanced for both very low and very high input flux conditions. Improvements in MCP manufacturing technology reported earlier have led to MCPs with substantially reduced radioisotope levels, giving dramatically lower internal background-counting rates. An update is given on the Galileo low noise MCP. Also, new results in increasing the MCP linear counting range for high input flux densities are presented. By bonding the active face of a very low resistance MCP (less than 1 megaohm) to a substrate providing a conductive path for heat transport, the bias current limit (hence, MCP output count rate limit) can be increased up to two orders of magnitude. Normal pulse-counting MCP operation was observed at bias currents of several mA when a curved-channel MCP (80:1) was bonded to a ceramic multianode substrate; the MCP temperature rise above ambient was less than 40 C.

  12. Dose and dose rate effects of whole-body gamma-irradiation: I. Lymphocytes and lymphoid organs

    NASA Technical Reports Server (NTRS)

    Pecaut, M. J.; Nelson, G. A.; Gridley, D. S.

    2001-01-01

    The major goal of part I of this study was to compare varying doses and dose rates of whole-body gamma-radiation on lymphoid cells and organs. C57BL/6 mice (n = 75) were exposed to 0, 0.5, 1.5, and 3.0 Gy gamma-rays (60Co) at 1 cGy/min (low-dose rate, LDR) and 80 cGy/min (high-dose rate, HDR) and euthanized 4 days later. A significant dose-dependent loss of spleen mass was observed with both LDR and HDR irradiation; for the thymus this was true only with HDR. Decreasing leukocyte and lymphocyte numbers occurred with increasing dose in blood and spleen at both dose rates. The numbers (not percentages) of CD3+ T lymphocytes decreased in the blood in a dose-dependent manner at both HDR and LDR. Splenic T cell counts decreased with dose only in HDR groups; percentages increased with dose at both dose rates. Dose-dependent decreases occurred in CD4+ T helper and CD8+ T cytotoxic cell counts at HDR and LDR. In the blood the percentages of CD4+ cells increased with increasing dose at both dose rates, whereas in the spleen the counts decreased only in the HDR groups. The percentages of the CD8+ population remained stable in both blood and spleen. CD19+ B cell counts and percentages in both compartments declined markedly with increasing HDR and LDR radiation. NK1.1+ natural killer cell numbers and proportions remained relatively stable. Overall, these data indicate that the observed changes were highly dependent on the dose, but not dose rate, and that cells in the spleen are more affected by dose rate than those in blood. The results also suggest that the response of lymphocytes in different body compartments may be variable.

  13. Cosmic-ray effects on diffuse gamma-ray measurements.

    NASA Technical Reports Server (NTRS)

    Fishman, G. J.

    1972-01-01

    Evaluation of calculations and experimental evidence from 600-MeV proton irradiation indicating that cosmic-ray-induced radioactivity in detectors used to measure the diffuse gamma-ray background produces a significant counting rate in the energy region around 1 MeV. It is concluded that these counts may be responsible for the observed flattening of the diffuse photon spectrum at this energy.

  14. Myocardial imaging with 123I-hexadecenoic acid.

    PubMed

    Poe, N D; Robinson, G D; Zielinski, F W; Cabeen, W R; Smith, J W; Gomes, A S

    1977-08-01

    123I-hexadecenoic acid is a terminally iodinated, 17-carbon fatty acid analog which is rapidly degraded in the myocardium. By determining regional myocardial distribution patterns and clearance rates, it may become useful as a single agent for estimating regional myocardial perfusion and for distinguished viable ischemic tissue from infarcted tissue. The high count rates obtainable with the iodine label permit acquisition of qualitative multiprojection images in only 3 min. per view, or quantifiable single projection high count images in 10 min. Ischemic defects may be observed in anginal patients without subjecting them to stress.

  15. Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

    NASA Technical Reports Server (NTRS)

    Van Amerom, Friso H.; Short, Tim; Brinckerhoff, William; Mahaffy, Paul; Kleyner, Igor; Cotter, Robert J.; Pinnick, Veronica; Hoffman, Lars; Danell, Ryan M.; Lyness, Eric I.

    2011-01-01

    The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

  16. Regression Analysis of Mixed Recurrent-Event and Panel-Count Data with Additive Rate Models

    PubMed Central

    Zhu, Liang; Zhao, Hui; Sun, Jianguo; Leisenring, Wendy; Robison, Leslie L.

    2015-01-01

    Summary Event-history studies of recurrent events are often conducted in fields such as demography, epidemiology, medicine, and social sciences (Cook and Lawless, 2007; Zhao et al., 2011). For such analysis, two types of data have been extensively investigated: recurrent-event data and panel-count data. However, in practice, one may face a third type of data, mixed recurrent-event and panel-count data or mixed event-history data. Such data occur if some study subjects are monitored or observed continuously and thus provide recurrent-event data, while the others are observed only at discrete times and hence give only panel-count data. A more general situation is that each subject is observed continuously over certain time periods but only at discrete times over other time periods. There exists little literature on the analysis of such mixed data except that published by Zhu et al. (2013). In this paper, we consider the regression analysis of mixed data using the additive rate model and develop some estimating equation-based approaches to estimate the regression parameters of interest. Both finite sample and asymptotic properties of the resulting estimators are established, and the numerical studies suggest that the proposed methodology works well for practical situations. The approach is applied to a Childhood Cancer Survivor Study that motivated this study. PMID:25345405

  17. The Pierre Auger Observatory scaler mode for the study of solar activity modulation of galactic cosmic rays

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abreu, P.; /Lisbon, LIFEP /Lisbon, IST; Aglietta, M.

    2011-01-01

    Since data-taking began in January 2004, the Pierre Auger Observatory has been recording the count rates of low energy secondary cosmic ray particles for the self-calibration of the ground detectors of its surface detector array. After correcting for atmospheric effects, modulations of galactic cosmic rays due to solar activity and transient events are observed. Temporal variations related with the activity of the heliosphere can be determined with high accuracy due to the high total count rates. In this study, the available data are presented together with an analysis focused on the observation of Forbush decreases, where a strong correlation withmore » neutron monitor data is found.« less

  18. Swift/XRT detects a new accretion outburst of the Galactic center neutron star transient GRS 1741-2853

    NASA Astrophysics Data System (ADS)

    Degenaar, N.; Wijnands, R.; Reynolds, M. T.; Miller, J. M.; Kennea, J. A.

    2017-10-01

    Daily Swift/XRT monitoring observations of the Galactic center (Degenaar et al. 2015) have picked up renewed activity of the transient neutron star low-mass X-ray binary and thermonuclear X-ray burster GRS 1741-2853, which is located 10 arcmin NW of Sgr A*. During a 1 ks PC-mode observation performed on 2017 October 11 the source is detected at a net count rate of 0.015 counts/s and it has been steadily brightening since, indicating the onset of a new accretion outburst.

  19. Statistical study of muons counts rates in differents directions, observed at the Brazilian Southern Space Observatory

    NASA Astrophysics Data System (ADS)

    Grams, Guilherme; Schuch, Nelson Jorge; Braga, Carlos Roberto; Purushottam Kane, Rajaram; Echer, Ezequiel; Ronan Coelho Stekel, Tardelli

    Cosmic ray are charged particles, at the most time protons, that reach the earth's magne-tosphere from interplanetary space with velocities greater than the solar wind. When these impinge the atmosphere, they interact with atmosphere constituents and decay into sub-particles forming an atmospheric shower. The muons are the sub-particles which normally maintain the originated direction of the primary cosmic ray. A multi-directional muon detec-tor (MMD) was installed in 2001 and upgraded in 2005, through an international cooperation between Brazil, Japan and USA, and operated since then at the Southern Space Observatory -SSO/CRS/CCR/INPE -MCT, (29,4° S, 53,8° W, 480m a.s.l.), São Martinho da Serra, RS, a Brazil. The main objetive of this work is to present a statistical analysis of the intensity of muons, with energy between 50 and 170 GeV, in differents directions, measured by the SSO's multi-directional muon detector. The analysis was performed with data from 2006 and 2007 collected by the SSO's MMD. The MMD consists of two layers of 4x7 detectors with a total observation area of 28 m2 . The counting of muons in each directional channel is made by a coincidence of pulses pair, one from a detector in the upper layer and the other from a detector in the lower layer. The SSO's MMD is equipped with 119 directional channels for muon count rate measurement and is capable of detecting muons incident with zenithal angle between 0° and 75,53° . A statistical analysis was made with the MMD muon count rate for all the di-rectional channels. The average and the standard deviation of the muon count rate in each directional component were calculated. The results show lower cont rate for the channels with larger zenith, and higher cont rate with smaller zenith, as expected from the production and propagation of muons in the atmosphere. It is also possible to identify the Stormer cone. The SSO's MMD is also a detector component of the Global Muon Detector Network (GMDN), which has been developed in an international collaboration lead by Shinshu University, Japan.

  20. Comparison of visual-based helicopter and fixed-wing forward-looking infrared surveys for counting white-tailed deer Odocoileus virginianus

    USGS Publications Warehouse

    Storm, Daniel J.; Samuel, Michael D.; Van Deelen, Timothy R.; Malcolm, Karl D.; Rolley, Robert E.; Frost, Nancy A.; Bates, Donald P.; Richards, Bryan J.

    2011-01-01

    Aerial surveys using direct counts of animals are commonly used to estimate deer abundance. Forward-looking infrared (FLIR) technology is increasingly replacing traditional methods such as visual observation from helicopters. Our goals were to compare fixed-wing FLIR and visual, helicopter-based counts in terms of relative bias, influence of snow cover and cost. We surveyed five plots: four 41.4 km2 plots with free-ranging white-tailed deer Odocoileus virginianus populations in Wisconsin and a 5.3 km2 plot with a white-tailed deer population contained by a high fence in Michigan. We surveyed plots using both fixed-wing FLIR and helicopters, both with snow cover and without snow. None of the methods counted more deer than the other when snow was present. Helicopter counts were lower in the absence of snow, but lack of snow cover did not apparently affect FLIR. Group sizes of observed deer were similar regardless of survey method or season. We found that FLIR counts were generally precise (CV = 0.089) when two or three replicate surveys were conducted within a few hours. However, at the plot level, FLIR counts differed greatly between seasons, suggesting that detection rates vary over larger time scales. Fixed-wing FLIR was more costly than visual observers in helicopters and was more restrictive in terms of acceptable survey conditions. Further research is needed to understand what factors influence the detection of deer during FLIR surveys.

  1. Spectra of solar proton ground level events using neutron monitor and neutron moderated detector recordings

    NASA Technical Reports Server (NTRS)

    Stoker, P. H.

    1985-01-01

    Recordings on relativistic solar flare protons observed at Sanae, Antarctic, show that the percentage increase in counting rates of the neutron moderated detector (4NMD) is larger than the percentage increase in counting rates of the 3NM64 neutron monitor. These relative increases are described by solar proton differential spectra j sub s(P) = AP(beta). The power beta is determined for each event and the hardnesses of the temporal variations of beta, found for the ground level events (GLE) of 7 May, 1978 and 22 November, 1977.

  2. NICER observations of MAXI J1820+070 suggest a rapidly-brightening black hole X-ray binary in the hard state

    NASA Astrophysics Data System (ADS)

    Uttley, P.; Gendreau, K.; Markwardt, C.; Strohmayer, T. E.; Bult, P.; Arzoumanian, Z.; Pottschmidt, K.; Ray, P. S.; Remillard, R.; Pasham, D.; Steiner, J.; Neilsen, J.; Homan, J.; Miller, J. M.; Iwakiri, W.; Fabian, A. C.

    2018-03-01

    NICER observed the new X-ray transient MAXI J1820+070 (ATel #11399, #11400, #11403, #11404, #11406, #11418, #11420, #11421) on multiple occasions from 2018 March 12 to 14. & nbsp;During this time the source brightened rapidly, from a total NICER mean count rate of 880 count/s on March 12 to 2800 count/s by March 14 17:00 & nbsp;UTC, corresponding to a change in 2-10 keV modelled flux (see below) from 1.9E-9 to 5E-9 erg cm-2 s-1. & nbsp; The broadband X-ray spectrum is absorbed by a low column density (fitting the model given below, we obtain 1.5E21 cm-2), in keeping with the low Galactic column in the direction of the source (ATel #11418; Dickey & Lockman, 1990, ARAA, 28, 215; Kalberla et al. 2005, A &A, 440, 775) and consists of a hard power-law component with weak reflection features (broad iron line and narrow 6.4 keV line core) and an additional soft X-ray component.

  3. Platelet Kinetics in Idiopathic Thrombocytopenic Purpura Patients Treated with Thrombopoietin Receptor Agonists

    PubMed Central

    Meyer, Oliver; Herzig, Eric; Salama, Abdulgabar

    2012-01-01

    Aim Thrombopoietin receptor agonists (Tpo RA) increase platelet counts in the majority of chronic autoimmune thrombocytopenia (idiopathic thrombocytopenic purpura; ITP) patients. It is unknown whether this treatment may also improve platelet survival (PS) in these patients. Methods In order to determine platelet survival (PS), autologous platelets were labeled with 111In oxine and retransfused in six patients under treatment with Tpo RA (romiplostim n = 3; eltrombopag n = 3). Results Stable platelet counts of greater than 100 × 103/μl were observed in all 6 patients. Platelet survival was decreased in all cases (mean 2.10 days; range 0.13–3.73 days). No correlation was found between platelet count and PS. Similarly, there was no significant relationship between platelet turnover and platelet count. However, a high platelet turnover, exceeding 25 or three times the norm was observed in 2 patients who presented the lowest PS (0.13 or 0.83 days). Two patients had a moderately shortened PS (1.91 or 2.42 days), and, correspondingly, a moderately increased platelet turnover rate (63,072 or 72,872 platelets/μl/day). Conclusion These results indicate that Tpo RA may not only overcompensate platelet destruction in ITP, but may interfere with other mechanisms, which, in some cases, results in a reduced platelet destruction rate. PMID:22896760

  4. Radioactivities of Long Duration Exposure Facility (LDEF) materials: Baggage and bonanzas

    NASA Technical Reports Server (NTRS)

    Smith, Alan R.; Hurley, Donna L.

    1991-01-01

    Radioactivities in materials onboard the returned Long Duration Exposure Facility (LDEF) satellite were studied by a variety of techniques. Among the most powerful is low background Ge semiconductor detector gamma ray spectrometry. The observed radioactivities are of two origins: those radionuclides produced by nuclear reactions with the radiation field in orbit and radionuclides present initially as contaminants in materials used for construction of the spacecraft and experimental assemblies. In the first category are experiment related monitor foils and tomato seeds, and such spacecraft materials as Al, stainless steel, and Ti. In the second category are Al, Be, Ti, Va, and some special glasses. Consider that measured peak-area count rates from both categories range from a high value of about 1 count per minute down to less than 0.001 count per minute. Successful measurement of count rates toward the low end of this range can be achieved only through low background techniques, such as used to obtain the results presented here.

  5. Radioactivities of Long Duration Exposure Facility (LDEF) materials: Baggage and bonanzas

    NASA Astrophysics Data System (ADS)

    Smith, Alan R.; Hurley, Donna L.

    1991-06-01

    Radioactivities in materials onboard the returned Long Duration Exposure Facility (LDEF) satellite were studied by a variety of techniques. Among the most powerful is low background Ge semiconductor detector gamma ray spectrometry. The observed radioactivities are of two origins: those radionuclides produced by nuclear reactions with the radiation field in orbit and radionuclides present initially as contaminants in materials used for construction of the spacecraft and experimental assemblies. In the first category are experiment related monitor foils and tomato seeds, and such spacecraft materials as Al, stainless steel, and Ti. In the second category are Al, Be, Ti, Va, and some special glasses. Consider that measured peak-area count rates from both categories range from a high value of about 1 count per minute down to less than 0.001 count per minute. Successful measurement of count rates toward the low end of this range can be achieved only through low background techniques, such as used to obtain the results presented here.

  6. Natural radioactive contaminants in solder

    NASA Astrophysics Data System (ADS)

    Bunzl, K.; Kracke, W.

    1985-07-01

    Comparatively high surface count rates for alpha- and beta-radiation were observed for several solders. They were identified as 210Pb and 210Po. The corresponding specific activities in solder were determined.

  7. Regression analysis of mixed recurrent-event and panel-count data with additive rate models.

    PubMed

    Zhu, Liang; Zhao, Hui; Sun, Jianguo; Leisenring, Wendy; Robison, Leslie L

    2015-03-01

    Event-history studies of recurrent events are often conducted in fields such as demography, epidemiology, medicine, and social sciences (Cook and Lawless, 2007, The Statistical Analysis of Recurrent Events. New York: Springer-Verlag; Zhao et al., 2011, Test 20, 1-42). For such analysis, two types of data have been extensively investigated: recurrent-event data and panel-count data. However, in practice, one may face a third type of data, mixed recurrent-event and panel-count data or mixed event-history data. Such data occur if some study subjects are monitored or observed continuously and thus provide recurrent-event data, while the others are observed only at discrete times and hence give only panel-count data. A more general situation is that each subject is observed continuously over certain time periods but only at discrete times over other time periods. There exists little literature on the analysis of such mixed data except that published by Zhu et al. (2013, Statistics in Medicine 32, 1954-1963). In this article, we consider the regression analysis of mixed data using the additive rate model and develop some estimating equation-based approaches to estimate the regression parameters of interest. Both finite sample and asymptotic properties of the resulting estimators are established, and the numerical studies suggest that the proposed methodology works well for practical situations. The approach is applied to a Childhood Cancer Survivor Study that motivated this study. © 2014, The International Biometric Society.

  8. Mathematics learning disability in girls with Turner syndrome or fragile X syndrome.

    PubMed

    Murphy, Melissa M; Mazzocco, Michèle M M; Gerner, Gwendolyn; Henry, Anne E

    2006-07-01

    Two studies were carried out to examine the persistence (Study 1) and characteristics (Study 2) of mathematics learning disability (MLD) in girls with Turner syndrome or fragile X during the primary school years (ages 5-9 years). In Study 1, the rate of MLD for each syndrome group exceeded the rate observed in a grade-matched comparison group, although the likelihood of MLD persisting through the primary school years was comparable for all three groups. In Study 2, formal and informal math skills were compared across the syndrome groups, a normative group, and children from the normative group who had MLD. Few differences were observed between the Turner syndrome and normative groups. Despite having rote counting and number representation skills comparable to those in the normative group, girls with fragile X had difficulty with counting rules (e.g., cardinality, number constancy). However, this difficulty did not distingush them from the MLD group. Overall, counting skills appear to distinguish the Turner syndrome and fragile X groups, suggesting that the specificity of math deficits emerges earlier for fragile X than Turner syndrome.

  9. Salivary characteristics of children and its relation to oral microorganism and lip mucosa dryness.

    PubMed

    Alamoudi, Najlaa; Farsi, Najat; Faris, Jamila; Masoud, Ibrahim; Merdad, Khaled; Meisha, Dalia

    2004-01-01

    The aim of this paper was to present baseline data on various saliva properties among a group of Saudi children aged 5 to 11 years and to study the relationship of these properties to some oral micro-organisms as well as to lip and oral mucosa dryness. The results showed a mean of resting and stimulated flow rate of 0.54 +/- 0.40 and 1.23 +/- 0.59 respectively and mean pH value of 7.27 +/- 0.38 and 7.5 +/- .035 respectively. Fluoride concentration was estimated to be 0.151 +/- 0.07 and 0.145 +/- 0.06 in resting and stimulated saliva respectively. Children with dry lip represented 33.9% of the sample population, whereas, those with dry mucosa represented only 0.8%. No significant sex difference was evident in all parameters. 59.1% of children showed medium buffering capacity in the resting saliva, whereas, the majority of children (73.7%) showed high stimulated buffering capacity. Children showed generally high Lactobacillus counts (Lb) in the resting and stimulated saliva (57.9% and 60.5% of children). The presence of yeast also in resting and stimulated saliva seemed high in general (40% and 53% of children had high count). However, Streptococcus mutans (S. mutans) counts showed no discriminating trend in both types of saliva. The data showed no significant association between flow rate and Lb counts in both resting and stimulated saliva although there was a trend toward higher counts associated with low flow rate. The same trend was observed in resting saliva although not significant. Similarly, low resting buffering capacity was associated with high counts of Lb among a high proportion of children (68.6% of children) although not significant. A significant reverse relation was evident between S. mutans counts and stimulated flow rate (p=0.049). The majority of children with normal level of saliva pH showed no yeast colonization (62.1%). The association was significant (p=.024). Similarly, the same association was observed in the medium and high buffering group (66.2%) (p=.040). It was concluded that salivary Lb count seems to be primarily affected by some local factors other than salivary properties, such as diet. Significant inverse relationship was found between S. mutans and stimulated salivary flow. Children in general showed high percentage of yeast reflecting the affect of poor diet among the studied population group. Buffering capacity and pH had an important role in yeast colonization.

  10. Results of the first continuous meteor head echo survey at polar latitudes

    NASA Astrophysics Data System (ADS)

    Schult, Carsten; Stober, Gunter; Janches, Diego; Chau, Jorge L.

    2017-11-01

    We present the first quasi continuous meteor head echo measurements obtained during a period of over two years using the Middle Atmosphere ALOMAR Radar System (MAARSY). The measurements yield information on the altitude, trajectory, vector velocity, radar cross section, deceleration and dynamical mass of every single event. The large statistical amount of nearly one million meteor head detections provide an excellent overview of the elevation, altitude, velocity and daily count rate distributions during different times of the year at polar latitudes. Only 40% of the meteors were detected within the full width half maximum of the specific sporadic meteor sources. Our observation of the sporadic meteors are compared to the observations with other radar systems and a meteor input function (MIF). The best way to compare different radar systems is by comparing the radar cross section (RCS), which is the main detection criterion for each system. In this study we aim to compare our observations with a MIF, which provides information only about the meteoroid mass. Thus, we are using a statistical approach for the elevation and velocity dependent visibility and a specific mass selection. The predicted absolute count rates from the MIF are in a good agreement with the observation when it is assumed that the radar system is only sensitive to meteoroids with masses higher than one microgram. The analysis of the dynamic masses seems to be consistent with this assumption since the count rate of events with smaller masses are low and decrease even more by using events with relatively small errors.

  11. A new clocking method for a charge coupled device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Umezu, Rika; Kitamoto, Shunji, E-mail: kitamoto@rikkyo.ac.jp; Murakami, Hiroshi

    2014-07-15

    We propose and demonstrate a new clocking method for a charge-coupled device (CCD). When a CCD is used for a photon counting detector of X-rays, its weak point is a limitation of its counting rate, because high counting rate makes non-negligible pile-up of photons. In astronomical usage, this pile-up is especially severe for an observation of a bright point-like object. One typical idea to reduce the pile-up is a parallel sum (P-sum) mode. This mode completely loses one-dimensional information. Our new clocking method, panning mode, provides complementary properties between the normal mode and the P-sum mode. We performed a simplemore » simulation in order to investigate a pile-up probability and compared the simulated result and actual obtained event rates. Using this simulation and the experimental results, we compared the pile-up tolerance of various clocking modes including our new method and also compared their other characteristics.« less

  12. The origin and reduction of spurious extrahepatic counts observed in 90Y non-TOF PET imaging post radioembolization

    NASA Astrophysics Data System (ADS)

    Walrand, Stephan; Hesse, Michel; Jamar, François; Lhommel, Renaud

    2018-04-01

    Our literature survey revealed a physical effect unknown to the nuclear medicine community, i.e. internal bremsstrahlung emission, and also the existence of long energy resolution tails in crystal scintillation. None of these effects has ever been modelled in PET Monte Carlo (MC) simulations. This study investigates whether these two effects could be at the origin of two unexplained observations in 90Y imaging by PET: the increasing tails in the radial profile of true coincidences, and the presence of spurious extrahepatic counts post radioembolization in non-TOF PET and their absence in TOF PET. These spurious extrahepatic counts hamper the microsphere delivery check in liver radioembolization. An acquisition of a 32P vial was performed on a GSO PET system. This is the ideal setup to study the impact of bremsstrahlung x-rays on the true coincidence rate when no positron emission and no crystal radioactivity are present. A MC simulation of the acquisition was performed using Gate-Geant4. MC simulations of non-TOF PET and TOF-PET imaging of a synthetic 90Y human liver radioembolization phantom were also performed. Internal bremsstrahlung and long energy resolution tails inclusion in MC simulations quantitatively predict the increasing tails in the radial profile. In addition, internal bremsstrahlung explains the discrepancy previously observed in bremsstrahlung SPECT between the measure of the 90Y bremsstrahlung spectrum and its simulation with Gate-Geant4. However the spurious extrahepatic counts in non-TOF PET mainly result from the failure of conventional random correction methods in such low count rate studies and poor robustness versus emission-transmission inconsistency. A novel proposed random correction method succeeds in cleaning the spurious extrahepatic counts in non-TOF PET. Two physical effects not considered up to now in nuclear medicine were identified to be at the origin of the unusual 90Y true coincidences radial profile. TOF reconstruction removing of the spurious extrahepatic counts was theoretically explained by a better robustness against emission-transmission inconsistency. A novel random correction method was proposed to overcome the issue in non-TOF PET. Further studies are needed to assess the novel random correction method robustness.

  13. Simultaneous Forbush decreases and associated geomagnetic storms during the last three solar cycles

    NASA Astrophysics Data System (ADS)

    Okpala, K. C.

    2013-12-01

    Forbush decrease (FD) are observed reduction in galactic cosmic ray (GCR) intensity as measured by ground neutron monitors. FD is associated with increased activity of the sun as reflected in the size of the interplanetary coronal mass ejections passing around the Earth and the corotating regions in the Heliosphere. Since the interplanetary anisotropy evolves itself during a geomagnetic storm in addition to the reconfiguration of external magnetospheric currents, it is expected that changes in transmissivity of cosmic rays of glactic origin will occur during Geomagnetic storms. In this study we examine over one hundred and fifty (150) FD events and associated geomagnetic storms over the last three solar cycles from 1970 to 2003. The negative peaks of the FDs and the Dst coincided for most of the events (~70%). There was good correlation (>0.65) between the FDs and Dst. Fresh evidence of the influence of external magnetospheric currents on the count rates of the neutron monitors stations during periods of Forbush decreases (FDs) is provided. This evidence is observed as sudden increases in the count rates during the main phase of simultaneous FD. The magnitude of the sudden rise in the count rates of Neutron monitors and peak dst correlated well (>0.50) both for high latitude and mid latitude stations.

  14. Compton suppression gamma-counting: The effect of count rate

    USGS Publications Warehouse

    Millard, H.T.

    1984-01-01

    Past research has shown that anti-coincidence shielded Ge(Li) spectrometers enhanced the signal-to-background ratios for gamma-photopeaks, which are situated on high Compton backgrounds. Ordinarily, an anti- or non-coincidence spectrum (A) and a coincidence spectrum (C) are collected simultaneously with these systems. To be useful in neutron activation analysis (NAA), the fractions of the photopeak counts routed to the two spectra must be constant from sample to sample to variations must be corrected quantitatively. Most Compton suppression counting has been done at low count rate, but in NAA applications, count rates may be much higher. To operate over the wider dynamic range, the effect of count rate on the ratio of the photopeak counts in the two spectra (A/C) was studied. It was found that as the count rate increases, A/C decreases for gammas not coincident with other gammas from the same decay. For gammas coincident with other gammas, A/C increases to a maximum and then decreases. These results suggest that calibration curves are required to correct photopeak areas so quantitative data can be obtained at higher count rates. ?? 1984.

  15. Pulse pileup statistics for energy discriminating photon counting x-ray detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Adam S.; Harrison, Daniel; Lobastov, Vladimir

    Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analyticallymore » for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.« less

  16. Einstein Observations of Galactic supernova remnants

    NASA Technical Reports Server (NTRS)

    Seward, Frederick D.

    1990-01-01

    This paper summarizes the observations of Galactic supernova remnants with the imaging detectors of the Einstein Observatory. X-ray surface brightness contours of 47 remnants are shown together with gray-scale pictures. Count rates for these remnants have been derived and are listed for the HRI, IPC, and MPC detectors.

  17. VizieR Online Data Catalog: Flux conversion factors for the Swift/UVOT filters (Brown+, 2016)

    NASA Astrophysics Data System (ADS)

    Brown, P. J.; Breeveld, A.; Roming, P. W. A.; Siegel, M.

    2016-10-01

    The conversion of observed magnitudes (or the actual observed photon or electron count rates) to a flux density is one of the most fundamental calculations. The flux conversions factors for the six Swift/UVOT filters are tabulated in Table1. (1 data file).

  18. Detector noise statistics in the non-linear regime

    NASA Technical Reports Server (NTRS)

    Shopbell, P. L.; Bland-Hawthorn, J.

    1992-01-01

    The statistical behavior of an idealized linear detector in the presence of threshold and saturation levels is examined. It is assumed that the noise is governed by the statistical fluctuations in the number of photons emitted by the source during an exposure. Since physical detectors cannot have infinite dynamic range, our model illustrates that all devices have non-linear regimes, particularly at high count rates. The primary effect is a decrease in the statistical variance about the mean signal due to a portion of the expected noise distribution being removed via clipping. Higher order statistical moments are also examined, in particular, skewness and kurtosis. In principle, the expected distortion in the detector noise characteristics can be calibrated using flatfield observations with count rates matched to the observations. For this purpose, some basic statistical methods that utilize Fourier analysis techniques are described.

  19. ChromAIX2: A large area, high count-rate energy-resolving photon counting ASIC for a Spectral CT Prototype

    NASA Astrophysics Data System (ADS)

    Steadman, Roger; Herrmann, Christoph; Livne, Amir

    2017-08-01

    Spectral CT based on energy-resolving photon counting detectors is expected to deliver additional diagnostic value at a lower dose than current state-of-the-art CT [1]. The capability of simultaneously providing a number of spectrally distinct measurements not only allows distinguishing between photo-electric and Compton interactions but also discriminating contrast agents that exhibit a K-edge discontinuity in the absorption spectrum, referred to as K-edge Imaging [2]. Such detectors are based on direct converting sensors (e.g. CdTe or CdZnTe) and high-rate photon counting electronics. To support the development of Spectral CT and show the feasibility of obtaining rates exceeding 10 Mcps/pixel (Poissonian observed count-rate), the ChromAIX ASIC has been previously reported showing 13.5 Mcps/pixel (150 Mcps/mm2 incident) [3]. The ChromAIX has been improved to offer the possibility of a large area coverage detector, and increased overall performance. The new ASIC is called ChromAIX2, and delivers count-rates exceeding 15 Mcps/pixel with an rms-noise performance of approximately 260 e-. It has an isotropic pixel pitch of 500 μm in an array of 22×32 pixels and is tile-able on three of its sides. The pixel topology consists of a two stage amplifier (CSA and Shaper) and a number of test features allowing to thoroughly characterize the ASIC without a sensor. A total of 5 independent thresholds are also available within each pixel, allowing to acquire 5 spectrally distinct measurements simultaneously. The ASIC also incorporates a baseline restorer to eliminate excess currents induced by the sensor (e.g. dark current and low frequency drifts) which would otherwise cause an energy estimation error. In this paper we report on the inherent electrical performance of the ChromAXI2 as well as measurements obtained with CZT (CdZnTe)/CdTe sensors and X-rays and radioactive sources.

  20. Final Technical Report- Radiation Hard Tight Pitch GaInP SPAD Arrays for High Energy Physics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harmon, Eric S.

    The specialized photodetectors used in high energy physics experiments often need to remain extremely sensitive for years despite radiation induced damage caused by the constant bombardment of high energy particles. To solve this problem, LightSpin Technologies, Inc. in collaboration with Prof. Bradley Cox and the University of Virginia is developing radiation-hard GaInP photodetectors which are projected to be extraordinarily radiation hard, theoretically capable of withstanding a 100,000-fold higher radiation dose than silicon. In this Phase I SBIR project, LightSpin investigated the performance and radiation hardness of fifth generation GaInP SPAD arrays. These fifth generation devices used a new planar processingmore » approach that enables very tight pitch arrays to be produced. High performance devices with SPAD pitches of 11, 15, and 25 μm were successfully demonstrated, which greatly increased the dynamic range and maximum count rate of the devices. High maximum count rates are critical when considering radiation hardness, since radiation damage causes a proportional increase in the dark count rate, causing SPAD arrays with low maximum count rates (large SPAD pitches) to fail. These GaInP SPAD array Photomultiplier Chips™ were irradiated with protons, electrons, and neutrons. Initial irradiation results were disappointing, with the post-irradiation devices exhibiting excessively high dark currents. The degradation was traced to surface leakage currents that were largely eliminated through the use of trenches etched around the exterior of the Photomultiplier Chip™ (not between SPAD elements). A second round of irradiations on Photomultiplier Chips™ with trenches proved substantially more successful, with post-irradiation dark currents remaining relatively low, though dark count rates were observed to increase at the highest doses. Preliminary analysis of the post-irradiation devices is promising … many of the irradiated Photomultiplier Chips™ still exhibit good gain characteristics after 1E12/cm 2 – 1E13/cm 2 doses and have apparent dark count rates that are lower than the apparent dark count rates published for irradiation of silicon SPAD arrays (silicon photomultipliers or SiPMs). Some post-irradiation results are still pending because the samples will still too radioactive to be shipped back from the irradiation facility for post-irradiation testing.« less

  1. Aerial population estimates of wild horses (Equus caballus) in the adobe town and salt wells creek herd management areas using an integrated simultaneous double-count and sightability bias correction technique

    USGS Publications Warehouse

    Lubow, Bruce C.; Ransom, Jason I.

    2007-01-01

    An aerial survey technique combining simultaneous double-count and sightability bias correction methodologies was used to estimate the population of wild horses inhabiting Adobe Town and Salt Wells Creek Herd Management Areas, Wyoming. Based on 5 surveys over 4 years, we conclude that the technique produced estimates consistent with the known number of horses removed between surveys and an annual population growth rate of 16.2 percent per year. Therefore, evidence from this series of surveys supports the validity of this survey method. Our results also indicate that the ability of aerial observers to see horse groups is very strongly dependent on skill of the individual observer, size of the horse group, and vegetation cover. It is also more modestly dependent on the ruggedness of the terrain and the position of the sun relative to the observer. We further conclude that censuses, or uncorrected raw counts, are inadequate estimates of population size for this herd. Such uncorrected counts were all undercounts in our trials, and varied in magnitude from year to year and observer to observer. As of April 2007, we estimate that the population of the Adobe Town /Salt Wells Creek complex is 906 horses with a 95 percent confidence interval ranging from 857 to 981 horses.

  2. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon.

    PubMed

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Ozcan; Sahin, Mahmut

    2014-09-01

    The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Patients' demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow.

  3. Marginalized zero-altered models for longitudinal count data.

    PubMed

    Tabb, Loni Philip; Tchetgen, Eric J Tchetgen; Wellenius, Greg A; Coull, Brent A

    2016-10-01

    Count data often exhibit more zeros than predicted by common count distributions like the Poisson or negative binomial. In recent years, there has been considerable interest in methods for analyzing zero-inflated count data in longitudinal or other correlated data settings. A common approach has been to extend zero-inflated Poisson models to include random effects that account for correlation among observations. However, these models have been shown to have a few drawbacks, including interpretability of regression coefficients and numerical instability of fitting algorithms even when the data arise from the assumed model. To address these issues, we propose a model that parameterizes the marginal associations between the count outcome and the covariates as easily interpretable log relative rates, while including random effects to account for correlation among observations. One of the main advantages of this marginal model is that it allows a basis upon which we can directly compare the performance of standard methods that ignore zero inflation with that of a method that explicitly takes zero inflation into account. We present simulations of these various model formulations in terms of bias and variance estimation. Finally, we apply the proposed approach to analyze toxicological data of the effect of emissions on cardiac arrhythmias.

  4. Marginalized zero-altered models for longitudinal count data

    PubMed Central

    Tabb, Loni Philip; Tchetgen, Eric J. Tchetgen; Wellenius, Greg A.; Coull, Brent A.

    2015-01-01

    Count data often exhibit more zeros than predicted by common count distributions like the Poisson or negative binomial. In recent years, there has been considerable interest in methods for analyzing zero-inflated count data in longitudinal or other correlated data settings. A common approach has been to extend zero-inflated Poisson models to include random effects that account for correlation among observations. However, these models have been shown to have a few drawbacks, including interpretability of regression coefficients and numerical instability of fitting algorithms even when the data arise from the assumed model. To address these issues, we propose a model that parameterizes the marginal associations between the count outcome and the covariates as easily interpretable log relative rates, while including random effects to account for correlation among observations. One of the main advantages of this marginal model is that it allows a basis upon which we can directly compare the performance of standard methods that ignore zero inflation with that of a method that explicitly takes zero inflation into account. We present simulations of these various model formulations in terms of bias and variance estimation. Finally, we apply the proposed approach to analyze toxicological data of the effect of emissions on cardiac arrhythmias. PMID:27867423

  5. A scaling relation between merger rate of galaxies and their close pair count

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, C. Y.; Jing, Y. P.; Han, Jiaxin, E-mail: ypjing@sjtu.edu.cn

    We study how to measure the galaxy merger rate from the observed close pair count. Using a high-resolution N-body/SPH cosmological simulation, we find an accurate scaling relation between galaxy pair counts and merger rates down to a stellar mass ratio of about 1:30. The relation explicitly accounts for the dependence on redshift (or time), on pair separation, and on mass of the two galaxies in a pair. With this relation, one can easily obtain the mean merger timescale for a close pair of galaxies. The use of virial masses, instead of the stellar mass, is motivated by the fact thatmore » the dynamical friction timescale is mainly determined by the dark matter surrounding central and satellite galaxies. This fact can also minimize the error induced by uncertainties in modeling star formation in the simulation. Since the virial mass can be determined from the well-established relation between the virial masses and the stellar masses in observations, our scaling relation can easily be applied to observations to obtain the merger rate and merger timescale. For major merger pairs (1:1-1:4) of galaxies above a stellar mass of 4 × 10{sup 10} h {sup –1} M{sub ☉} at z = 0.1, it takes about 0.31 Gyr to merge for pairs within a projected distance of 20 h {sup –1} kpc with a stellar mass ratio of 1:1, while the time goes up to 1.6 Gyr for mergers with stellar mass ratio of 1:4. Our results indicate that a single timescale usually used in the literature is not accurate to describe mergers with a stellar mass ratio spanning even a narrow range from 1:1 to 1:4.« less

  6. Association of asymptomatic oral candidal carriage, oral candidiasis and CD4 lymphocyte count in HIV-positive patients in China.

    PubMed

    Liu, X; Liu, H; Guo, Z; Luan, W

    2006-01-01

    To compare the prevalence of asymptomatic oral candidal carriage in healthy volunteers with human immunodeficiency virus (HIV)-positive patients in China, as well as to investigate the relationship between CD4+ lymphocyte count and oral candidal colonization or oral candidiasis. Oral candidal carriage and oral candidiasis were investigated in 101 patients with HIV-infection seen at Youan Hospital, Beijing, China. Two hundred and seventeen healthy volunteers were involved as a control. Culture from saliva was used to test for the presence of oral Candida. CD4+ lymphocyte count was measured by flow cytometry. All data were analyzed statistically by SAS. Asymptomatic oral candidal carriage rate (28.6%) in HIV-positive group was similar to that in the healthy group (18.0%; P = 0.07). No significant difference in CD4+ lymphocyte count was found between oral Candida carriers and non-carriers among HIV-positive subjects (P = 0.89). However, the frequency of oral candidiasis increased with the decrease in CD4+ lymphocyte count (P < 0.0001), and pseudomembranous candidiasis was predominant in HIV-positive patients with CD4+ <200 cells microl(-1) (66.7%). In HIV-positive subjects, asymptomatic oral candidal colonization is not related to CD4+ lymphocyte count of blood, and the carriage rate is similar to that in the healthy population. Oral candidiasis is more likely to be observed in HIV-positive patients who have a low CD4+ lymphocyte count.

  7. Aging and Visual Counting

    PubMed Central

    Li, Roger W.; MacKeben, Manfred; Chat, Sandy W.; Kumar, Maya; Ngo, Charlie; Levi, Dennis M.

    2010-01-01

    Background Much previous work on how normal aging affects visual enumeration has been focused on the response time required to enumerate, with unlimited stimulus duration. There is a fundamental question, not yet addressed, of how many visual items the aging visual system can enumerate in a “single glance”, without the confounding influence of eye movements. Methodology/Principal Findings We recruited 104 observers with normal vision across the age span (age 21–85). They were briefly (200 ms) presented with a number of well- separated black dots against a gray background on a monitor screen, and were asked to judge the number of dots. By limiting the stimulus presentation time, we can determine the maximum number of visual items an observer can correctly enumerate at a criterion level of performance (counting threshold, defined as the number of visual items at which ≈63% correct rate on a psychometric curve), without confounding by eye movements. Our findings reveal a 30% decrease in the mean counting threshold of the oldest group (age 61–85: ∼5 dots) when compared with the youngest groups (age 21–40: 7 dots). Surprisingly, despite decreased counting threshold, on average counting accuracy function (defined as the mean number of dots reported for each number tested) is largely unaffected by age, reflecting that the threshold loss can be primarily attributed to increased random errors. We further expanded this interesting finding to show that both young and old adults tend to over-count small numbers, but older observers over-count more. Conclusion/Significance Here we show that age reduces the ability to correctly enumerate in a glance, but the accuracy (veridicality), on average, remains unchanged with advancing age. Control experiments indicate that the degraded performance cannot be explained by optical, retinal or other perceptual factors, but is cortical in origin. PMID:20976149

  8. The piecewise-linear dynamic attenuator reduces the impact of count rate loss with photon-counting detectors

    NASA Astrophysics Data System (ADS)

    Hsieh, Scott S.; Pelc, Norbert J.

    2014-06-01

    Photon counting x-ray detectors (PCXDs) offer several advantages compared to standard energy-integrating x-ray detectors, but also face significant challenges. One key challenge is the high count rates required in CT. At high count rates, PCXDs exhibit count rate loss and show reduced detective quantum efficiency in signal-rich (or high flux) measurements. In order to reduce count rate requirements, a dynamic beam-shaping filter can be used to redistribute flux incident on the patient. We study the piecewise-linear attenuator in conjunction with PCXDs without energy discrimination capabilities. We examined three detector models: the classic nonparalyzable and paralyzable detector models, and a ‘hybrid’ detector model which is a weighted average of the two which approximates an existing, real detector (Taguchi et al 2011 Med. Phys. 38 1089-102 ). We derive analytic expressions for the variance of the CT measurements for these detectors. These expressions are used with raw data estimated from DICOM image files of an abdomen and a thorax to estimate variance in reconstructed images for both the dynamic attenuator and a static beam-shaping (‘bowtie’) filter. By redistributing flux, the dynamic attenuator reduces dose by 40% without increasing peak variance for the ideal detector. For non-ideal PCXDs, the impact of count rate loss is also reduced. The nonparalyzable detector shows little impact from count rate loss, but with the paralyzable model, count rate loss leads to noise streaks that can be controlled with the dynamic attenuator. With the hybrid model, the characteristic count rates required before noise streaks dominate the reconstruction are reduced by a factor of 2 to 3. We conclude that the piecewise-linear attenuator can reduce the count rate requirements of the PCXD in addition to improving dose efficiency. The magnitude of this reduction depends on the detector, with paralyzable detectors showing much greater benefit than nonparalyzable detectors.

  9. Particle emission from artificial cometary materials

    NASA Technical Reports Server (NTRS)

    Koelzer, Gabriele; Kochan, Hermann; Thiel, Klaus

    1992-01-01

    During KOSI (comet simulation) experiments, mineral-ice mixtures are observed in simulated space conditions. Emission of ice-/dust particles from the sample surface is observed by means of different devices. The particle trajectories are recorded with a video system. In the following analysis we extracted the parameters: particle count rate, spatial distribution of starting points on the sample surface, and elevation angle and particle velocity at distances up to 5 cm from the sample surface. Different kinds of detectors are mounted on a frame in front of the sample to register the emitted particles and to collect their dust residues. By means of these instruments the particle count rates, the particle sizes and the composition of the particles can be correlated. The results are related to the gas flux density and the temperature on the sample surface during the insolation period. The particle emission is interpreted in terms of phenomena on the sample surface, e.g., formation of a dust mantle.

  10. ROSAT Observations of Solar Wind Charge Exchange with the Lunar Exosphere

    NASA Technical Reports Server (NTRS)

    Collier, Michael R.; Snowden, S. L.; Benna, M.; Carter, J. A.; Cravens, T. E.; Hills, H. Kent; Hodges, R. R.; Kuntz, K. D.; Porter, F. Scott; Read, A.; hide

    2012-01-01

    We analyze the ROSAT PSPC soft X-ray image of the Moon taken on 29 June 1990 by examining the radial profile of the count rate in three wedges, two wedges (one north and one south) 13-32 degrees off (19 degrees wide) the terminator towards the dark side and one wedge 38 degrees wide centered on the anti-solar direction. The radial profiles of both the north and the south wedges show substantial limb brightening that is absent in the 38 degree wide antisolar wedge. An analysis of the count rate increase associated with the limb brightening shows that its magnitude is consistent with that expected due to solar wind charge exchange (SWCX) with the tenuous lunar atmosphere. Along with Mars, Venus, and Earth, the Moon represents another solar system body at which solar wind charge exchange has been observed. This technique can be used to explore the solar wind-lunar interaction.

  11. The long-term intensity behavior of Centaurus X-3

    NASA Technical Reports Server (NTRS)

    Schreier, E. J.; Swartz, K.; Giacconi, R.; Fabbiano, G.; Morin, J.

    1976-01-01

    In three years of observation, the X-ray source Cen X-3 appears to alternate between 'high states', with an intensity of 150 counts/s (2-6 keV) or greater, and 'low states', where the source is barely detectable. The time scale of this behavior is of the order of months, and no apparent periodicity has been observed. Analysis of two transitions between these states is reported. During two weeks in July 1972, the source increased from about 20 counts/s to 150 counts/s. The detailed nature of this turn-on is interpreted in terms of a model in which the supergiant's stellar wind decreases in density. A second transition, a turnoff in February 1973, is similarly analyzed and found to be consistent with a simple decrease in accretion rate. The presence of absorption dips during transitions at orbital phases 0.4-0.5 as well as at phase 0.75 is discussed. The data are consistent with a stellar-wind accretion model and with different kinds of extended lows caused by increased wind density masking the X-ray emission or by decreased wind density lowering the accretion rate.

  12. NEMA count-rate evaluation of the first and second generation of the Ecat Exact and Ecat Exact HR family of scanners

    NASA Astrophysics Data System (ADS)

    Eriksson, L.; Wienhard, K.; Eriksson, M.; Casey, M. E.; Knoess, C.; Bruckbauer, T.; Hamill, J.; Mulnix, T.; Vollmar, S.; Bendriem, B.; Heiss, W. D.; Nutt, R.

    2002-06-01

    The first and second generation of the Exact and Exact HR family of scanners has been evaluated in terms of noise equivalent count rate (NEC) and count-rate capabilities. The new National Electrical Manufacturers Association standard was used for the evaluation. In spite of improved electronics and improved count-rate capabilities, the peak NEC was found to be fairly constant between the generations. The results are discussed in terms of the different electronic solutions for the two generations and its implications on system dead time and NEC count-rate capability.

  13. Compensated count-rate circuit for radiation survey meter

    DOEpatents

    Todd, Richard A.

    1981-01-01

    A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for counting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensated circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

  14. Effects of SMEAT on the oral health of crewmen (DTO 71-2). [dental hygiene

    NASA Technical Reports Server (NTRS)

    Brown, L. R.; Wheatcroft, M. G.

    1973-01-01

    The oral health status of three astronauts was monitored before, during and after a 56-day simulation of the Skylab mission. Laboratory and clinical parameters which are considered to be ultimately related to dental impairments were evaluated. The most notable changes were observed in increased counts of mycoplasma and S. mutans, decreased counts of enteric bacilli, decreased saliva flow rates, increased secretory IgA and salivary lysozyme levels, and increased clinical scores of dental plaque, calculus and inflammation.

  15. Historical versus Contemporary Climate Forcing on the Annual Nesting Variability of Loggerhead Sea Turtles in the Northwest Atlantic Ocean

    PubMed Central

    Arendt, Michael D.; Schwenter, Jeffrey A.; Witherington, Blair E.; Meylan, Anne B.; Saba, Vincent S.

    2013-01-01

    A recent analysis suggested that historical climate forcing on the oceanic habitat of neonate sea turtles explained two-thirds of interannual variability in contemporary loggerhead (Caretta caretta) sea turtle nest counts in Florida, where nearly 90% of all nesting by this species in the Northwest Atlantic Ocean occurs. Here, we show that associations between annual nest counts and climate conditions decades prior to nest counts and those conditions one year prior to nest counts were not significantly different. Examination of annual nest count and climate data revealed that statistical artifacts influenced the reported 31-year lag association with nest counts. The projected importance of age 31 neophytes to annual nest counts between 2020 and 2043 was modeled using observed nest counts between 1989 and 2012. Assuming consistent survival rates among cohorts for a 5% population growth trajectory and that one third of the mature female population nests annually, the 41% decline in annual nest counts observed during 1998–2007 was not projected for 2029–2038. This finding suggests that annual nest count trends are more influenced by remigrants than neophytes. Projections under the 5% population growth scenario also suggest that the Peninsular Recovery Unit could attain the demographic recovery criteria of 106,100 annual nests by 2027 if nest counts in 2019 are at least comparable to 2012. Because the first year of life represents only 4% of the time elapsed through age 31, cumulative survival at sea across decades explains most cohort variability, and thus, remigrant population size. Pursuant to the U.S. Endangered Species Act, staggered implementation of protection measures for all loggerhead life stages has taken place since the 1970s. We suggest that the 1998–2007 nesting decline represented a lagged perturbation response to historical anthropogenic impacts, and that subsequent nest count increases since 2008 reflect a potential recovery response. PMID:24339901

  16. Historical versus contemporary climate forcing on the annual nesting variability of loggerhead sea turtles in the Northwest Atlantic Ocean.

    PubMed

    Arendt, Michael D; Schwenter, Jeffrey A; Witherington, Blair E; Meylan, Anne B; Saba, Vincent S

    2013-01-01

    A recent analysis suggested that historical climate forcing on the oceanic habitat of neonate sea turtles explained two-thirds of interannual variability in contemporary loggerhead (Caretta caretta) sea turtle nest counts in Florida, where nearly 90% of all nesting by this species in the Northwest Atlantic Ocean occurs. Here, we show that associations between annual nest counts and climate conditions decades prior to nest counts and those conditions one year prior to nest counts were not significantly different. Examination of annual nest count and climate data revealed that statistical artifacts influenced the reported 31-year lag association with nest counts. The projected importance of age 31 neophytes to annual nest counts between 2020 and 2043 was modeled using observed nest counts between 1989 and 2012. Assuming consistent survival rates among cohorts for a 5% population growth trajectory and that one third of the mature female population nests annually, the 41% decline in annual nest counts observed during 1998-2007 was not projected for 2029-2038. This finding suggests that annual nest count trends are more influenced by remigrants than neophytes. Projections under the 5% population growth scenario also suggest that the Peninsular Recovery Unit could attain the demographic recovery criteria of 106,100 annual nests by 2027 if nest counts in 2019 are at least comparable to 2012. Because the first year of life represents only 4% of the time elapsed through age 31, cumulative survival at sea across decades explains most cohort variability, and thus, remigrant population size. Pursuant to the U.S. Endangered Species Act, staggered implementation of protection measures for all loggerhead life stages has taken place since the 1970s. We suggest that the 1998-2007 nesting decline represented a lagged perturbation response to historical anthropogenic impacts, and that subsequent nest count increases since 2008 reflect a potential recovery response.

  17. Bayesian analysis of energy and count rate data for detection of low count rate radioactive sources.

    PubMed

    Klumpp, John; Brandl, Alexander

    2015-03-01

    A particle counting and detection system is proposed that searches for elevated count rates in multiple energy regions simultaneously. The system analyzes time-interval data (e.g., time between counts), as this was shown to be a more sensitive technique for detecting low count rate sources compared to analyzing counts per unit interval (Luo et al. 2013). Two distinct versions of the detection system are developed. The first is intended for situations in which the sample is fixed and can be measured for an unlimited amount of time. The second version is intended to detect sources that are physically moving relative to the detector, such as a truck moving past a fixed roadside detector or a waste storage facility under an airplane. In both cases, the detection system is expected to be active indefinitely; i.e., it is an online detection system. Both versions of the multi-energy detection systems are compared to their respective gross count rate detection systems in terms of Type I and Type II error rates and sensitivity.

  18. Investigations of Wind/WAVES Dust Impacts

    NASA Astrophysics Data System (ADS)

    St Cyr, O. C.; Wilson, L. B., III; Rockcliffe, K.; Mills, A.; Nieves-Chinchilla, T.; Adrian, M. L.; Malaspina, D.

    2017-12-01

    The Wind spacecraft launched in November 1994 with a primary goal to observe and understand the interaction between the solar wind and Earth's magnetosphere. The waveform capture detector, TDS, of the radio and plasma wave investigation, WAVES [Bougeret et al., 1995], onboard Wind incidentally detected micron-sized dust as electric field pulses from the recollection of the impact plasma clouds (an unintended objective). TDS has detected over 100,000 dust impacts spanning almost two solar cycles; a dataset of these impacts has been created and was described in Malaspina & Wilson [2016]. The spacecraft continues to collect data about plasma, energetic particles, and interplanetary dust impacts. Here we report on two investigations recently conducted on the Wind/WAVES TDS database of dust impacts. One possible source of dust particles is the annually-recurring meteor showers. Using the nine major showers defined by the American Meteor Society, we compared dust count rates before, during, and after the peak of the showers using averaging windows of varying duration. However, we found no statistically significant change in the dust count rates due to major meteor showers. This appears to be an expected result since smaller grains, like the micron particles that Wind is sensitive to, are affected by electromagnetic interactions and Poynting-Robertson drag, and so are scattered away from their initial orbits. Larger grains tend to be more gravitationally dominated and stay on the initial trajectory of the parent body so that only the largest dust grains (those that create streaks as they burn up in the atmosphere) are left in the orbit of the parent body. Ragot and Kahler [2003] predicted that coronal mass ejections (CMEs) near the Sun could effectively scatter dust grains of comparable size to those observed by Wind. Thus, we examined the dust count rates immediately before, during, and after the passage of the 350 interplanetary CMEs observed by Wind over its 20+ year lifetime. We found a statistically significant and consistent trend of count rate deficits during the ICMEs compared to the periods immediately before and after the ICMEs. These preliminary results suggest that ICMEs may scatter micron-sized dust, or that they may exclude it during their initiation.

  19. Does the covariance structure matter in longitudinal modelling for the prediction of future CD4 counts?

    PubMed

    Taylor, J M; Law, N

    1998-10-30

    We investigate the importance of the assumed covariance structure for longitudinal modelling of CD4 counts. We examine how individual predictions of future CD4 counts are affected by the covariance structure. We consider four covariance structures: one based on an integrated Ornstein-Uhlenbeck stochastic process; one based on Brownian motion, and two derived from standard linear and quadratic random-effects models. Using data from the Multicenter AIDS Cohort Study and from a simulation study, we show that there is a noticeable deterioration in the coverage rate of confidence intervals if we assume the wrong covariance. There is also a loss in efficiency. The quadratic random-effects model is found to be the best in terms of correctly calibrated prediction intervals, but is substantially less efficient than the others. Incorrectly specifying the covariance structure as linear random effects gives too narrow prediction intervals with poor coverage rates. Fitting using the model based on the integrated Ornstein-Uhlenbeck stochastic process is the preferred one of the four considered because of its efficiency and robustness properties. We also use the difference between the future predicted and observed CD4 counts to assess an appropriate transformation of CD4 counts; a fourth root, cube root and square root all appear reasonable choices.

  20. Ageing and long-term CD4 cell count trends in HIV-positive patients with 5 years or more combination antiretroviral therapy experience.

    PubMed

    Wright, S T; Petoumenos, K; Boyd, M; Carr, A; Downing, S; O'Connor, C C; Grotowski, M; Law, M G

    2013-04-01

    The aim of this study was to describe the long-term changes in CD4 cell counts beyond 5 years of combination antiretroviral therapy (cART). If natural ageing leads to a long-term decline in the immune system via low-grade chronic immune activation/inflammation, then one might expect to see a greater or earlier decline in CD4 counts in older HIV-positive patients with increasing duration of cART. Retrospective and prospective data were examined from long-term virologically stable HIV-positive adults from the Australian HIV Observational Database. We estimated mean CD4 cell count changes following the completion of 5 years of cART using linear mixed models. A total of 37 916 CD4 measurements were observed for 892 patients over a combined total of 9753 patient-years. Older patients (> 50 years old) at cART initiation had estimated mean (95% confidence interval) changes in CD4 counts by year-5 CD4 count strata (< 500, 500-750 and > 750 cells/μL) of 14 (7 to 21), 3 (-5 to 11) and -6 (-17 to 4) cells/μL/year. Of the CD4 cell count rates of change estimated, none were indicative of long-term declines in CD4 cell counts. Our results suggest that duration of cART and increasing age do not result in decreasing mean changes in CD4 cell counts for long-term virologically suppressed patients, indicating that the level of immune recovery achieved during the first 5 years of treatment is sustained through long-term cART. © 2012 British HIV Association.

  1. Ageing & long-term CD4 cell count trends in HIV-positive patients with 5 years or more combination antiretroviral therapy experience

    PubMed Central

    WRIGHT, ST; PETOUMENOS, K; BOYD, M; CARR, A; DOWNING, S; O’CONNOR, CC; GROTOWSKI, M; LAW, MG

    2012-01-01

    Background The aim of this analysis is to describe the long-term changes in CD4 cell counts beyond 5 years of combination antiretroviral therapy (cART). If natural ageing leads to a long-term decline in the immune system via low-grade chronic immune activation/inflammation, then one might expect to see a greater or earlier decline in CD4 counts in older HIV-positive patients with increasing duration of cART. Methods Retrospective and prospective data were examined from long-term virologically stable HIV-positive adults from the Australian HIV Observational Database. We estimated mean CD4 cell counts changes following the completion of 5 years of cART using linear mixed models. Results A total of 37,916 CD4 measurements were observed for 892 patients over a combined total of 9,753 patient years. Older patients (>50 years) at cART initiation had estimated mean(95% confidence interval) change in CD4 counts by Year-5 CD4 count strata (<500, 501–750 and >750 cells/μL) of 14(7 to 21), 3(−5 to 11) and −6(−17 to 4) cells/μL/year. Of the CD4 cell count rates of change estimated, none were indicative of long-term declines in CD4 cell counts. Conclusions Our results suggest that duration of cART and increasing age does not result in decreasing mean changes in CD4 cell counts for long-term virologically suppressed patients. Indicating that level of immune recovery achieved during the first 5 years of treatment are sustained through long-term cART. PMID:23036045

  2. Direct Observations of ULF and Whistler-Mode Chorus Modulation of 500eV EDI Electrons by MMS

    NASA Astrophysics Data System (ADS)

    Paulson, K. W.; Argall, M. R.; Ahmadi, N.; Torbert, R. B.; Le Contel, O.; Ergun, R.; Khotyaintsev, Y. V.; Strangeway, R. J.; Magnes, W.; Russell, C. T.

    2016-12-01

    We present here direct observations of chorus-wave modulated field-aligned 500 eV electrons using the Electron Drift Instrument (EDI) on board the Magnetospheric Multiscale mission. These periods of wave activity were additionally observed to be modulated by Pc5-frequency magnetic perturbations, some of which have been identified as drifting mirror-mode structures. The spacecraft encountered these mirror-mode structures just inside of the duskside magnetopause. Using the high sampling rate provided by EDI in burst sampling mode, we are able to observe the individual count fluctuations of field-aligned electrons in this region up to 512 Hz. We use the multiple look directions of EDI to generate both pitch angle and gyrophase plots of the fluctuating counts. Our observations often show unidirectional flow of these modulated electrons along the background field, and in some cases demonstrate gyrophase bunching in the wave region.

  3. Knowledge of resting heart rate mediates the relationship between intelligence and the heartbeat counting task.

    PubMed

    Murphy, Jennifer; Millgate, Edward; Geary, Hayley; Ichijo, Eri; Coll, Michel-Pierre; Brewer, Rebecca; Catmur, Caroline; Bird, Geoffrey

    2018-03-01

    Evidence suggests that intelligence is positively associated with performance on the heartbeat counting task (HCT). The HCT is often employed as measure of interoception - the ability to perceive the internal state of one's body - however it's use remains controversial as performance on the HCT is strongly influenced by knowledge of resting heart rate. This raises the possibility that heart rate knowledge may mediate the previously-observed association between intelligence and HCT performance. Study One demonstrates an association between intelligence and HCT performance (N = 94), and Study Two demonstrates that this relationship is mediated by knowledge of the average resting heart rate (N = 134). These data underscore the need to account for the influence of prior knowledge and beliefs when examining individual differences in cardiac interoceptive accuracy using the HCT. Copyright © 2018 The Author(s). Published by Elsevier B.V. All rights reserved.

  4. Is a top-heavy initial mass function needed to reproduce the submillimetre galaxy number counts?

    NASA Astrophysics Data System (ADS)

    Safarzadeh, Mohammadtaher; Lu, Yu; Hayward, Christopher C.

    2017-12-01

    Matching the number counts and redshift distribution of submillimetre galaxies (SMGs) without invoking modifications to the initial mass ffunction (IMF) has proved challenging for semi-analytic models (SAMs) of galaxy formation. We adopt a previously developed SAM that is constrained to match the z = 0 galaxy stellar mass function and makes various predictions which agree well with observational constraints; we do not recalibrate the SAM for this work. We implement three prescriptions to predict the submillimetre flux densities of the model galaxies; two depend solely on star formation rate, whereas the other also depends on the dust mass. By comparing the predictions of the models, we find that taking into account the dust mass, which affects the dust temperature and thus influences the far-infrared spectral energy distribution, is crucial for matching the number counts and redshift distribution of SMGs. Moreover, despite using a standard IMF, our model can match the observed SMG number counts and redshift distribution reasonably well, which contradicts the conclusions of some previous studies that a top-heavy IMF, in addition to taking into account the effect of dust mass, is needed to match these observations. Although we have not identified the key ingredient that is responsible for our model matching the observed SMG number counts and redshift distribution without IMF variation - which is challenging given the different prescriptions for physical processes employed in the SAMs of interest - our results demonstrate that in SAMs, IMF variation is degenerate with other physical processes, such as stellar feedback.

  5. A comparison of acoustic and visual metrics of sperm whale longline depredation.

    PubMed

    Thode, Aaron M; Wild, Lauren; Mathias, Delphine; Straley, Janice; Lunsford, Christopher

    2014-05-01

    Annual federal stock assessment surveys for Alaskan sablefish also attempt to measure sperm whale depredation by quantifying visual evidence of depredation, including lip remains and damaged fish. A complementary passive acoustic method for quantifying depredation was investigated during the 2011 and 2012 survey hauls. A combination of machine-aided and human analysis counted the number of distinct “creak” sounds detected on autonomous recorders deployed during the survey, emphasizing sounds that are followed by silence (“creak-pauses”), a possible indication of prey capture. These raw counts were then adjusted for variations in background noise levels between deployments. Both a randomized Pearson correlation analysis and a generalized linear model found that noise-adjusted counts of “creak-pauses” were highly correlated with survey counts of lip remains during both years (2012: r(10) = 0.89, p = 1e-3; 2011: r(39) = 0.72, p = 4e-3) and somewhat correlated with observed sablefish damage in 2011 [r(39) = 0.37, p = 0.03], but uncorrelated with other species depredation. The acoustic depredation count was anywhere from 10% to 80% higher than the visual counts, depending on the survey year and assumptions employed. The results suggest that passive acoustics can provide upper bounds on depredation rates; however, the observed correlation breaks down whenever three or more whales are present.

  6. In Orbit Performance of Si Avalanche Photodiode Single Photon Counting Modules in the Geoscience Laser Altimeter System on ICESat

    NASA Technical Reports Server (NTRS)

    Sun, X.; Jester, P. L.; Palm, S. P.; Abshire, J. B.; Spinhime, J. D.; Krainak, M. A.

    2006-01-01

    Si avalanche photodiode (APD) single photon counting modules (SPCMs) are used in the Geoscience Laser Altimeter System (GLAS) on Ice, Cloud, anti land Elevation Satellite (ICESat), currently in orbit measuring Earth surface elevation and atmosphere backscattering. These SPCMs are used to measure cloud and aerosol backscatterings to the GLAS laser light at 532-nm wavelength with 60-70% quantum efficiencies and up to 15 millions/s maximum count rates. The performance of the SPCMs has been closely monitored since ICESat launch on January 12, 2003. There has been no measurable change in the quantum efficiency, as indicated by the average photon count rates in response to the background light from the sunlit earth. The linearity and the afterpulsing seen from the cloud and surface backscatterings profiles have been the same as those during ground testing. The detector dark count rates monitored while the spacecraft was in the dark side of the globe have increased almost linearly at about 60 counts/s per day due to space radiation damage. The radiation damage appeared to be independent of the device temperature and power states. There was also an abrupt increase in radiation damage during the solar storm in 28-30 October 2003. The observed radiation damage is a factor of two to three lower than the expected and sufficiently low to provide useful atmosphere backscattering measurements through the end of the ICESat mission. To date, these SPCMs have been in orbit for more than three years. The accumulated operating time to date has reached 290 days (7000 hours). These SPCMs have provided unprecedented receiver sensitivity and dynamic range in ICESat atmosphere backscattering measurements.

  7. Relationship between salivary flow rates and Candida albicans counts.

    PubMed

    Navazesh, M; Wood, G J; Brightman, V J

    1995-09-01

    Seventy-one persons (48 women, 23 men; mean age, 51.76 years) were evaluated for salivary flow rates and Candida albicans counts. Each person was seen on three different occasions. Samples of unstimulated whole, chewing-stimulated whole, acid-stimulated parotid, and candy-stimulated parotid saliva were collected under standardized conditions. An oral rinse was also obtained and evaluated for Candida albicans counts. Unstimulated and chewing-stimulated whole flow rates were negatively and significantly (p < 0.001) related to the Candida counts. Unstimulated whole saliva significantly (p < 0.05) differed in persons with Candida counts of 0 versus <500 versus < or = 500. Chewing-stimulated saliva was significantly (p < 0.05) different in persons with 0 counts compared with those with a > or = 500 count. Differences in stimulated parotid flow rates were not significant among different levels of Candida counts. The results of this study reveal that whole saliva is a better predictor than parotid saliva in identification of persons with high Candida albicans counts.

  8. In-Flight Observation of Gamma Ray Glows by ILDAS.

    PubMed

    Kochkin, Pavlo; van Deursen, A P J; Marisaldi, M; Ursi, A; de Boer, A I; Bardet, M; Allasia, C; Boissin, J-F; Flourens, F; Østgaard, N

    2017-12-16

    An Airbus A340 aircraft flew over Northern Australia with the In-Flight Lightning Damage Assessment System (ILDAS) installed onboard. A long-duration gamma ray emission was detected. The most intense emission was observed at 12 km altitude and lasted for 20 s. Its intensity was 20 times the background counts, and it was abruptly terminated by a distant lightning flash. In this work we reconstruct the aircraft path and event timeline. The glow-terminating flash triggered a discharge from the aircraft wing that was recorded by a video camera operating onboard. Another count rate increase was observed 6 min later and lasted for 30 s. The lightning activity as reported by ground networks in this region was analyzed. The measured spectra characteristics of the emission were estimated.

  9. In-Flight Observation of Gamma Ray Glows by ILDAS

    NASA Astrophysics Data System (ADS)

    Kochkin, Pavlo; van Deursen, A. P. J.; Marisaldi, M.; Ursi, A.; de Boer, A. I.; Bardet, M.; Allasia, C.; Boissin, J.-F.; Flourens, F.; Østgaard, N.

    2017-12-01

    An Airbus A340 aircraft flew over Northern Australia with the In-Flight Lightning Damage Assessment System (ILDAS) installed onboard. A long-duration gamma ray emission was detected. The most intense emission was observed at 12 km altitude and lasted for 20 s. Its intensity was 20 times the background counts, and it was abruptly terminated by a distant lightning flash. In this work we reconstruct the aircraft path and event timeline. The glow-terminating flash triggered a discharge from the aircraft wing that was recorded by a video camera operating onboard. Another count rate increase was observed 6 min later and lasted for 30 s. The lightning activity as reported by ground networks in this region was analyzed. The measured spectra characteristics of the emission were estimated.

  10. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE PAGES

    Godfrey, B.; Anderson, T.; Breedon, E.; ...

    2018-03-26

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  11. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godfrey, B.; Anderson, T.; Breedon, E.

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  12. A Six-Year Study on the Changes in Airborne Pollen Counts and Skin Positivity Rates in Korea: 2008–2013

    PubMed Central

    Park, Hye Jung; Lee, Jae-Hyun; Park, Kyung Hee; Kim, Kyu Rang; Han, Mae Ja; Choe, Hosoeng

    2016-01-01

    Purpose The occurrence of pollen allergy is subject to exposure to pollen, which shows regional and temporal variations. We evaluated the changes in pollen counts and skin positivity rates for 6 years, and explored the correlation between their annual rates of change. Materials and Methods We assessed the number of pollen grains collected in Seoul, and retrospectively reviewed the results of 4442 skin-prick tests conducted at the Severance Hospital Allergy-Asthma Clinic from January 1, 2008 to December 31, 2013. Results For 6 years, the mean monthly total pollen count showed two peaks, one in May and the other in September. Pollen count for grasses also showed the same trend. The pollen counts for trees, grasses, and weeds changed annually, but the changes were not significant. The annual skin positivity rates in response to pollen from grasses and weeds increased significantly over the 6 years. Among trees, the skin positivity rates in response to pollen from walnut, popular, elm, and alder significantly increased over the 6 years. Further, there was a significant correlation between the annual rate of change in pollen count and the rate of change in skin positivity rate for oak and hop Japanese. Conclusion The pollen counts and skin positivity rates should be monitored, as they have changed annually. Oak and hop Japanese, which showed a significant correlation with the annual rate of change in pollen count and the rate of change in skin positivity rate over the 6 years may be considered the major allergens in Korea. PMID:26996572

  13. A Six-Year Study on the Changes in Airborne Pollen Counts and Skin Positivity Rates in Korea: 2008-2013.

    PubMed

    Park, Hye Jung; Lee, Jae-Hyun; Park, Kyung Hee; Kim, Kyu Rang; Han, Mae Ja; Choe, Hosoeng; Oh, Jae-Won; Hong, Chein-Soo

    2016-05-01

    The occurrence of pollen allergy is subject to exposure to pollen, which shows regional and temporal variations. We evaluated the changes in pollen counts and skin positivity rates for 6 years, and explored the correlation between their annual rates of change. We assessed the number of pollen grains collected in Seoul, and retrospectively reviewed the results of 4442 skin-prick tests conducted at the Severance Hospital Allergy-Asthma Clinic from January 1, 2008 to December 31, 2013. For 6 years, the mean monthly total pollen count showed two peaks, one in May and the other in September. Pollen count for grasses also showed the same trend. The pollen counts for trees, grasses, and weeds changed annually, but the changes were not significant. The annual skin positivity rates in response to pollen from grasses and weeds increased significantly over the 6 years. Among trees, the skin positivity rates in response to pollen from walnut, popular, elm, and alder significantly increased over the 6 years. Further, there was a significant correlation between the annual rate of change in pollen count and the rate of change in skin positivity rate for oak and hop Japanese. The pollen counts and skin positivity rates should be monitored, as they have changed annually. Oak and hop Japanese, which showed a significant correlation with the annual rate of change in pollen count and the rate of change in skin positivity rate over the 6 years may be considered the major allergens in Korea.

  14. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon

    PubMed Central

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Özcan; Sahin, Mahmut

    2014-01-01

    Background and Objective: The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Methods: Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Results: Patients’ demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Conclusion: Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow. PMID:25225502

  15. Impact of double counting and transfer bias on estimated rates and outcomes of acute myocardial infarction.

    PubMed

    Westfall, J M; McGloin, J

    2001-05-01

    Ischemic heart disease is the leading cause of death in the United States. Recent studies report inconsistent findings on the changes in the incidence of hospitalizations for ischemic heart disease. These reports have relied primarily on hospital discharge data. Preliminary data suggest that a significant percentage of patients suffering acute myocardial infarction (MI) in rural communities are transferred to urban centers for care. Patients transferred to a second hospital may be counted twice for one episode of ischemic heart disease. To describe the impact of double counting and transfer bias on the estimation of incidence rates and outcomes of ischemic heart disease, specifically acute MI, in the United States. Analysis of state hospital discharge data from Kansas, Colorado (State Inpatient Database [SID]), Nebraska, Arizona, New Jersey, Michigan, Pennsylvania, and Illinois (SID) for the years 1995 to 1997. A matching algorithm was developed for hospital discharges to determine patients counted twice for one episode of ischemic heart disease. Validation of our matching algorithm. Patients reported to have suffered ischemic heart disease (ICD9 codes 410-414, 786.5). Number of patients counted twice for one episode of acute MI. It is estimated that double count rates range from 10% to 15% for all states and increased over the 3 years. Moderate sized rural counties had the highest estimated double count rates at 15% to 20% with a few counties having estimated double count rates a high as 35% to 50%. Older patients and females were less likely to be double counted (P <0.05). Double counting patients has resulted in a significant overestimation in the incidence rate for hospitalization for acute MI. Correction of this double counting reveals a significantly lower incidence rate and a higher in-hospital mortality rate for acute MI. Transferred patients differ significantly from nontransferred patients, introducing significant bias into MI outcome studies. Double counting and transfer bias should be considered when conducting and interpreting research on ischemic heart disease, particularly in rural regions.

  16. Antral follicle counts are strongly associated with live-birth rates after assisted reproduction, with superior treatment outcome in women with polycystic ovaries.

    PubMed

    Holte, Jan; Brodin, Thomas; Berglund, Lars; Hadziosmanovic, Nermin; Olovsson, Matts; Bergh, Torbjörn

    2011-09-01

    To evaluate the association of antral follicle count (AFC) with in vitro fertilization/intracytoplasmic sperm injection (IVF-ICSI) outcome in a large unselected cohort of patients covering the entire range of AFC. Prospective observational study. University-affiliated private infertility center. 2,092 women undergoing 4,308 IVF-ICSI cycles. AFC analyzed for associations with treatment outcome and statistically adjusted for repeated treatments and age. Pregnancy rate, live-birth rate, and stimulation outcome parameters. The AFC was log-normally distributed. Pregnancy rates and live-birth rates were positively associated with AFC in a log-linear way, leveling out above AFC ∼30. Treatment outcome was superior among women with polycystic ovaries, independent from ovulatory status. The findings were significant also after adjustment for age and number of oocytes retrieved. Pregnancy and live-birth rates are log-linearly related to AFC. Polycystic ovaries, most often excluded from studies on ovarian reserve, fit as one extreme in the spectrum of AFC; a low count constitutes the other extreme, with the lowest ovarian reserve and poor treatment outcome. The findings remained statistically significant also after adjustment for the number of oocytes retrieved, suggesting this measure of ovarian reserve comprises information on oocyte quality and not only quantity. Copyright © 2011 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  17. Failure to prescribe pneumocystis prophylaxis is associated with increased mortality, even in the cART era: results from the Treat Asia HIV observational database

    PubMed Central

    2012-01-01

    Background Pneumocystis jiroveci pneumonia (PCP) prophylaxis is recommended for patients with CD4 counts of less than 200 cells/mm3. This study examines the proportion of patients in the TREAT Asia HIV Observational Database (TAHOD) receiving PCP prophylaxis, and its effect on PCP and mortality. Methods TAHOD patients with prospective follow up had data extracted for prophylaxis using co-trimoxazole, dapsone or pentamidine. The proportion of patients on prophylaxis was calculated for each calendar year since 2003 among patients with CD4 counts of less than 200 cells/mm3. The effect of prophylaxis on PCP and survival were assessed using random-effect Poisson regression models. Results There were a total of 4050 patients on prospective follow up, and 90% of them were receiving combination antiretroviral therapy. Of those with CD4 counts of less than 200 cells/mm3, 58% to 72% in any given year received PCP prophylaxis, predominantly co-trimoxazole. During follow up, 62 patients developed PCP (0.5 per 100 person-years) and 169 died from all causes (1.36/100 person-years). After stratifying by site and adjusting for age, CD4 count, CDC stage and antiretroviral treatment, those without prophylaxis had no higher risk of PCP, but had a significantly higher risk of death (incident rate ratio 10.8, p < 0.001). PCP prophylaxis had greatest absolute benefit in patients with CD4 counts of less than 50 cells/mm3, lowering mortality rates from 33.5 to 6.3 per 100 person-years. Conclusions Approximately two-thirds of TAHOD patients with CD4 counts of less than 200 cells/mm3 received PCP prophylaxis. Patients without prophylaxis had significantly higher mortality, even in the era of combination ART. Although PCP may be under-diagnosed, these data suggest that prophylaxis is associated with important survival benefits. PMID:22281054

  18. Measurement of energetic radiation caused by thunderstorm activities by a sounding balloon and ground observation

    NASA Astrophysics Data System (ADS)

    Torii, T.

    2015-12-01

    Energetic radiation caused by thunderstorm activity is observed at various places, such as the ground, high mountain areas, and artificial satellites. In order to investigate the radiation source and its energy distribution, we measured energetic radiation by a sounding balloon, and the ground observation. On the measurement inside/above the thundercloud, we conducted a sounding observation using a radiosonde mounted two GM tubes (for gamma-rays, and for beta/gamma-rays), in addition to meteorological instruments. The balloon passed through a region of strong echoes in a thundercloud shown by radar image, at which time an increase in counting rate of the GM tube about 2 orders of magnitude occurred at the altitude from 5 km to 7.5 km. Furthermore, the counting rate of two GM tubes indicated the tendency different depending on movement of a balloon. This result suggests that the ratio for the gamma-rays (energetic photons) of the beta-rays (energetic electrons) varies according to the place in the thundercloud. Furthermore, we carried out a ground observation of the energetic gamma rays during winter thunderstorm at a coastal area facing the Sea of Japan. Two types of the energetic radiation have been observed at this time. We report the outline of these measurements and analysis in the session of the AGU meeting.

  19. Influence of type of prosthesis on oral environment and the number of missing teeth in elderly persons.

    PubMed

    Tanaka, Junko; Tanaka, Masahiro

    2010-01-01

    The purpose of this study was to investigate the relationship between the number of missing teeth (MT) and the statuses of oral environmental factors (the stimulated salivary flow rate, buffering capacity, and the counts of mutans streptococci, lactobacilli, and Candida) in the elderly. The subjects were 64 elderly subjects with fixed prostheses and 49 who wore removable partial dentures aged over 65 years. We used one-way ANOVA to test for overall differences of the number of MT among 5 oral environmental factors. The significant differences were observed in the lactobacilli counts for different number of MT. The number of MT increased with an increase in the lactobacilli counts with removable denture. In conclusion, for the patients wearing removable dentures, increasing number of MT was associated with an increase in the lactobacilli counts in saliva. For the patients with crowns and fixed partial dentures, the number of MT was not significantly affected by salivary mutans streptococci, lactobacilli, and Candida counts.

  20. TU-FG-209-03: Exploring the Maximum Count Rate Capabilities of Photon Counting Arrays Based On Polycrystalline Silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liang, A K; Koniczek, M; Antonuk, L E

    Purpose: Photon counting arrays (PCAs) offer several advantages over conventional, fluence-integrating x-ray imagers, such as improved contrast by means of energy windowing. For that reason, we are exploring the feasibility and performance of PCA pixel circuitry based on polycrystalline silicon. This material, unlike the crystalline silicon commonly used in photon counting detectors, lends itself toward the economic manufacture of radiation tolerant, monolithic large area (e.g., ∼43×43 cm2) devices. In this presentation, exploration of maximum count rate, a critical performance parameter for such devices, is reported. Methods: Count rate performance for a variety of pixel circuit designs was explored through detailedmore » circuit simulations over a wide range of parameters (including pixel pitch and operating conditions) with the additional goal of preserving good energy resolution. The count rate simulations assume input events corresponding to a 72 kVp x-ray spectrum with 20 mm Al filtration interacting with a CZT detector at various input flux rates. Output count rates are determined at various photon energy threshold levels, and the percentage of counts lost (e.g., due to deadtime or pile-up) is calculated from the ratio of output to input counts. The energy resolution simulations involve thermal and flicker noise originating from each circuit element in a design. Results: Circuit designs compatible with pixel pitches ranging from 250 to 1000 µm that allow count rates over a megacount per second per pixel appear feasible. Such rates are expected to be suitable for radiographic and fluoroscopic imaging. Results for the analog front-end circuitry of the pixels show that acceptable energy resolution can also be achieved. Conclusion: PCAs created using polycrystalline silicon have the potential to offer monolithic large-area detectors with count rate performance comparable to those of crystalline silicon detectors. Further improvement through detailed circuit simulations and prototyping is expected. Partially supported by NIH grant R01-EB000558. This work was partially supported by NIH grant no. R01-EB000558.« less

  1. An observational study of spectators’ step counts and reasons for attending a professional golf tournament in Scotland

    PubMed Central

    Murray, Andrew D; Turner, Kieran; Archibald, Daryll; Schiphorst, Chloe; Griffin, Steffan Arthur; Scott, Hilary; Hawkes, Roger; Kelly, Paul; Grant, Liz; Mutrie, Nanette

    2017-01-01

    Background Spectators at several hundred golf tournaments on six continents worldwide may gain health-enhancing physical activity (HEPA) during their time at the event. This study aims to investigate spectators’ reasons for attending and assess spectator physical activity (PA) (measured by step count). Methods Spectators at the Paul Lawrie Matchplay event in Scotland (August 2016) were invited to take part in this study. They were asked to complete a brief questionnaire with items to assess (1) demographics, (2) reasons for attendance and (3) baseline PA. In addition, participants were requested to wear a pedometer from time of entry to the venue until exit. Results A total of 339 spectators were recruited to the study and out of which 329 (97.2%) returned step-count data. Spectators took a mean of 11 589 steps (SD 4531). ‘Fresh air’ (rated median 9 out of 10) then ‘watching star players’, ‘exercise/physical activity’, ‘time with friends and family’ and ‘atmosphere’ (all median 8 out of 10) were rated the most important reasons for attending. Conclusion This study is the first to assess spectator physical activity while watching golf (measured by step count). Obtaining exercise/PA is rated as an important reason for attending a tournament by many golf spectators. Spectating at a golf tournament can provide HEPA. 82.9% of spectators achieved the recommended daily step count while spectating. Further research directly assessing whether spectating may constitute a ‘teachable moment’, for increasing physical activity beyond the tournament itself, is merited. PMID:28761718

  2. In-situ observations of a bi-modal ion distribution in the outer coma of comet P/Halley

    NASA Technical Reports Server (NTRS)

    Thomsen, M. F.; Feldman, W. C.; Wilken, B.; Jockers, K.; Stuedemann, W.

    1987-01-01

    Observations obtained by the Johnstone Plasma Analyzer on the Giotto fly-by of comet Halley showed a fairly sudden decrease in the count rate of energetic (about 30 KeV) water-group ions inside about 500,000 km from the nucleus. This decrease was accompanied by the appearance of a new water-group ion population at slightly lower energies (less than 10 KeV). Close inspection reveals that this lower-energy peak was also present somewhat earlier in the postshock flow but only became prominent near the sudden transition just described. It is shown that the observed bimodal ion distribution is well explained in terms of the velocity history of the accreting solar wind flow in the outer coma. The decline in count rate of the energetic pick-up distribution is due to a relatively sudden slowing of the bulk flow there and not to a loss of particles. Hence, charge-exchange cooling of the flow is probably not important at these distances from the nucleus. The observations suggest that pitch-angle scattering is fairly efficient at least after the bow shock, but that energy diffusion is probably not very efficient.

  3. Observed diurnal variations in Mars Science Laboratory Dynamic Albedo of Neutrons passive mode data

    NASA Astrophysics Data System (ADS)

    Tate, C. G.; Moersch, J.; Jun, I.; Mitrofanov, I.; Litvak, M.; Boynton, W. V.; Drake, D.; Fedosov, F.; Golovin, D.; Hardgrove, C.; Harshman, K.; Kozyrev, A. S.; Kuzmin, R.; Lisov, D.; Maclennan, E.; Malakhov, A.; Mischna, M.; Mokrousov, M.; Nikiforov, S.; Sanin, A. B.; Starr, R.; Vostrukhin, A.

    2018-06-01

    The Mars Science Laboratory Dynamic Albedo of Neutrons (DAN) experiment measures the martian neutron leakage flux in order to estimate the amount of water equivalent hydrogen present in the shallow regolith. When DAN is operating in passive mode, it is sensitive to neutrons produced through the interactions of galactic cosmic rays (GCR) with the regolith and atmosphere and neutrons produced by the rover's Multi-Mission Radioisotope Thermoelectric Generator (MMRTG). During the mission, DAN passive mode data were collected over the full diurnal cycle at the locations known as Rocknest (sols 60-100) and John Klein (sols 166-272). A weak, but unexpected, diurnal variation was observed in the neutron count rates reported at these locations. We investigate different hypotheses that could be causing these observed variations. These hypotheses are variations in subsurface temperature, atmospheric pressure, the exchange of water vapor between the atmosphere and regolith, and instrumental effects on the neutron count rates. Our investigation suggests the most likely factors contributing to the observed diurnal variations in DAN passive data are instrumental effects and time-variable preferential shielding of alpha particles, with other environmental effects only having small contributions.

  4. Solar Wind Change Exchange from the Magnetosheath

    NASA Technical Reports Server (NTRS)

    Snowden, Steve

    2008-01-01

    We report the results of a long (approximately 100 ks) XMM-Newton observation designed to observe solar wind charge exchange emission (SWCX) from Earth's magnetosheath. By luck, the observation took place during a period of minimal solar wind flux so the SWCX emission was also minimal. Never-the-less, there is a significant if not stunning correlation between the observed O VIII count rate and our model for magnetosheath emission. We also report on the observed O VII and O VII emission.

  5. Photon Counting Detectors for the 1.0 - 2.0 Micron Wavelength Range

    NASA Technical Reports Server (NTRS)

    Krainak, Michael A.

    2004-01-01

    We describe results on the development of greater than 200 micron diameter, single-element photon-counting detectors for the 1-2 micron wavelength range. The technical goals include quantum efficiency in the range 10-70%; detector diameter greater than 200 microns; dark count rate below 100 kilo counts-per-second (cps), and maximum count rate above 10 Mcps.

  6. Fission meter and neutron detection using poisson distribution comparison

    DOEpatents

    Rowland, Mark S; Snyderman, Neal J

    2014-11-18

    A neutron detector system and method for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. Comparison of the observed neutron count distribution with a Poisson distribution is performed to distinguish fissile material from non-fissile material.

  7. CD4 cell responses to combination antiretroviral therapy in patients starting therapy at high CD4 cell counts.

    PubMed

    Wright, Stephen T; Carr, Andrew; Woolley, Ian; Giles, Michelle; Hoy, Jennifer; Cooper, David A; Law, Matthew G

    2011-09-01

    To examine CD4 cell responses to combination antiretroviral therapy (cART) in patients enrolled in the Australian HIV Observational Database who commenced cART at CD4 cell counts >350 cells per microliter. CD4 cell counts were modelled using random effects, repeated measurement models in 432 HIV-infected adults from Australian HIV Observational Database who commenced their first cART regimen and had a baseline CD4 count >350 cells per microliter. Using published AIDS and/or death incidence rates combined with the data summarized by time and predicted CD4 cell count, we calculated the expected reduction in risk of an event for different starting baseline CD4 strata. Mean CD4 counts increased above 500 cells per microliter in all baseline CD4 strata by 12 months (means of 596, 717, and 881 cells/μL in baseline CD4 strata 351-500, 501-650, and >650 cells/μL, respectively) and after 72 months since initiating cART, mean CD4 cell counts (by increasing baseline CD4 strata) were 689, 746, 742 cells per microliter. The expected reduction in risk of mortality for baseline CD4 counts >650 cells per microliter relative to 351-500 cells per microliter was approximately 8%, an absolute risk reduction 0.33 per 1000 treated patient-years. Patients starting cART at high CD4 cell counts (>650 cells/μL) tend to maintain this immunological level over 6 years of follow-up. Patients starting from 351 to 500 CD4 cells per microliter achieve levels of >650 cells per microliter after approximately 3 years of cART. Initiating cART with a baseline CD4 count 501-650 or >650 cells per microliter relative to 351-500 cells per microliter indicated a minimal reduction in risk of AIDS incidence and/or death.

  8. 500-514 N. Peshtigo Ct, May 2018, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    maximum gamma count rate for each lift was recorded on the attached RadiationSurvey Forms. Count rates in the excavation ranged from 1,800 cpm - 5,000 cpm.No count rates were found at any time that exceeded the instrument specific thresholdlimits.

  9. 550 E. Illinois, May 2018, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Maximum gamma count rate for each lift was recorded on the attached RadiationSurvey Forms. Count rates in the excavation ranged from 1,250 cpm to 4,880 cpm.No count rates were found at any time that exceeded the instrument specific thresholdlimits.

  10. EUVE Right Angle Program Observations of Late-Type Stars

    NASA Astrophysics Data System (ADS)

    Christian, D. J.; Mathioudakis, M.; Drake, J. J.

    1995-12-01

    The EUVE Right Angle Program (RAP) obtains photometric data in four bands centered at ~ 100 Angstroms (Lexan/B), ~ 200 Angstroms (Al/Ti/C), ~ 400 Angstroms (Ti/Sb/Al), and ~ 550 Angstroms (Sn/SiO). RAP observations are up to 20 times more sensitive than the all-sky survey. We present RAP observations of the late-type stars: BD+03 301, BD+05 300, HR 1262, BD+23 635, BD+22 669, Melotte 25 VA 334, Melotte 25 1366, Melotte 25 59, Melotte 25 65, theta (1) Tau, V834 Tau, GJ 2037, BD-21 1074, GJ 205, RE J0532-030, GJ 9287A, HT Vir, BD+46 1944, Proxima Cen, alpha Cen A/B, HR 6094, CPD-48 10901, and HR 8883. We derive fluxes and emission measures from Lexan/B and Al/Ti/C count rates. The time variability of the sources has been examined. Most of the sources show no significant variability at the 99% confidence level. Flares were detected from the K3V star V834 Tau (HD 29697) and the K0 star BD+22 669. The BD+22 669 count rate at the peak of the flare is a factor of 10 higher than the quiescent count rate with a peak Lexan/B luminosity of 7.9 x 10(29) erg s(-1) . The V834 Tau flare was detected in both Lexan/B and Al/Ti/C bands. The peak luminosity of the flare is 1.6 x 10(29) erg s(-1) and 8 x 10(28) ergs s(-1) for Lexan/B and Al/Ti/C, respectively. This is a factor of 4.3 higher than the quiescent luminosity in Lexan/B, and a factor of 4.6 in Al/Ti/C\\@. This work is supported by NASA contract NAS5-29298.

  11. Compensated count-rate circuit for radiation survey meter

    DOEpatents

    Todd, R.A.

    1980-05-12

    A count-rate compensating circuit is provided which may be used in a portable Geiger-Mueller (G-M) survey meter to ideally compensate for couting loss errors in the G-M tube detector. In a G-M survey meter, wherein the pulse rate from the G-M tube is converted into a pulse rate current applied to a current meter calibrated to indicate dose rate, the compensation circuit generates and controls a reference voltage in response to the rate of pulses from the detector. This reference voltage is gated to the current-generating circuit at a rate identical to the rate of pulses coming from the detector so that the current flowing through the meter is varied in accordance with both the frequency and amplitude of the reference voltage pulses applied thereto so that the count rate is compensated ideally to indicate a true count rate within 1% up to a 50% duty cycle for the detector. A positive feedback circuit is used to control the reference voltage so that the meter output tracks true count rate indicative of the radiation dose rate.

  12. A STUDY OF VARIOUS RADIATIONS DURING SPACE FLIGHTS OF SPUTNIKS, SPACE SHIPS AND ROCKETS (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vakulov, P.V.; Vernov, S.N.; Gorchakov, E.V.

    1962-06-01

    Data are presented on various radiation zones observed during the flights of the 3rd sputnik (launched May 15th, ship (Aug. 19 to 20, 1960, 339 km apogee and a 306 km perigee), the 3rd space ship (Dec. 1 to 2, 1960, 265 km apogee and a 187.3 km perigee), and the space rocket launched toward Venus on Feb. 12th, 1961. A radiation belt of electrons was detected at a height of 320 km above the earth's surface from the bremsstrahlung radiation determined on Geiger- Mueller and scintillation counters. Conjugate zones in the Northern hemisphere were linked with corresponding zones inmore » the Southern hemisphere. The position of the electron belt has remained relatively constant for about two years. The electron spectrum does not vary significantly. A count rate of >3.6 counts cm/ sup -2/ sec/sup -1/ was obtained in a Geiger-Mueller counter in the South Atlantic Ocean off the coast of Brazil. This high count rate was due to a magnetic anomaly in this region. An accurate distribution of cosmic ray intensity as a function of latitute was obtained from a comparison of the counts of the scintillation counter and the count of the STS-5 gas-discharge counter. Thirty references are included. (TTT)« less

  13. 2015-2016 Palila abundance estimates

    USGS Publications Warehouse

    Camp, Richard J.; Brinck, Kevin W.; Banko, Paul C.

    2016-01-01

    The palila (Loxioides bailleui) population was surveyed annually during 1998−2016 on Mauna Kea Volcano to determine abundance, population trend, and spatial distribution. In the latest surveys, the 2015 population was estimated at 852−1,406 birds (point estimate: 1,116) and the 2016 population was estimated at 1,494−2,385 (point estimate: 1,934). Similar numbers of palila were detected during the first and subsequent counts within each year during 2012−2016; the proportion of the total annual detections in each count ranged from 46% to 56%; and there was no difference in the detection probability due to count sequence. Furthermore, conducting repeat counts improved the abundance estimates by reducing the width of the confidence intervals between 9% and 32% annually. This suggests that multiple counts do not affect bird or observer behavior and can be continued in the future to improve the precision of abundance estimates. Five palila were detected on supplemental survey stations in the Ka‘ohe restoration area, outside the core survey area but still within Palila Critical Habitat (one in 2015 and four in 2016), suggesting that palila are present in habitat that is recovering from cattle grazing on the southwest slope. The average rate of decline during 1998−2016 was 150 birds per year. Over the 18-year monitoring period, the estimated rate of change equated to a 58% decline in the population.

  14. Asm-Triggered too Observations of Z Sources at Low Accretion Rate

    NASA Astrophysics Data System (ADS)

    van der Klis, Michiel

    We propose to perform a pointed observation if the ASM shows that a Z source has entered a state of low accretion rate. This would provide a unique opportunity to detect millisecond pulsations. In Sco X-1 we would expect to discover beat-frequency QPO, and could perform a unique high count rate study of them. At sufficiently low accretion rate it would be possible to study the accretion flow when the magnetospheric radius approaches the corotation radius. The frequency of the horizontal branch QPO should go to zero here, and centrifugal inhibition of the accretion should set in, providing direct tests of the magnetospheric model of Z sources.

  15. Designing the X-Ray Microcalorimeter Spectrometer for Optimal Science Return

    NASA Technical Reports Server (NTRS)

    Ptak, Andrew; Bandler, Simon R.; Bookbinder, Jay; Kelley, Richard L.; Petre, Robert; Smith, Randall K.; Smith, Stephen

    2013-01-01

    Recent advances in X-ray microcalorimeters enable a wide range of possible focal plane designs for the X-ray Microcalorimeter Spectrometer (XMS) instrument on the future Advanced X-ray Spectroscopic Imaging Observatory (AXSIO) or X-ray Astrophysics Probe (XAP). Small pixel designs (75 microns) oversample a 5-10" PSF by a factor of 3-6 for a 10 m focal length, enabling observations at both high count rates and high energy resolution. Pixel designs utilizing multiple absorbers attached to single transition-edge sensors can extend the focal plane to cover a significantly larger field of view, albeit at a cost in maximum count rate and energy resolution. Optimizing the science return for a given cost and/or complexity is therefore a non-trivial calculation that includes consideration of issues such as the mission science drivers, likely targets, mirror size, and observing efficiency. We present a range of possible designs taking these factors into account and their impacts on the science return of future large effective-area X-ray spectroscopic missions.

  16. The MIT/OSO 7 catalog of X-ray sources - Intensities, spectra, and long-term variability

    NASA Technical Reports Server (NTRS)

    Markert, T. H.; Laird, F. N.; Clark, G. W.; Hearn, D. R.; Sprott, G. F.; Li, F. K.; Bradt, H. V.; Lewin, W. H. G.; Schnopper, H. W.; Winkler, P. F.

    1979-01-01

    This paper is a summary of the observations of the cosmic X-ray sky performed by the MIT 1-40-keV X-ray detectors on OSO 7 between October 1971 and May 1973. Specifically, mean intensities or upper limits of all third Uhuru or OSO 7 cataloged sources (185 sources) in the 3-10-keV range are computed. For those sources for which a statistically significant (greater than 20) intensity was found in the 3-10-keV band (138 sources), further intensity determinations were made in the 1-15-keV, 1-6-keV, and 15-40-keV energy bands. Graphs and other simple techniques are provided to aid the user in converting the observed counting rates to convenient units and in determining spectral parameters. Long-term light curves (counting rates in one or more energy bands as a function of time) are plotted for 86 of the brighter sources.

  17. The Preflight Photometric Calibration of the Extreme-Ultraviolet Imaging Telescope EIT

    NASA Technical Reports Server (NTRS)

    Dere, K. P.; Moses, J. D.; Delaboudiniere, J. -P.; Brunaud, J.; Carabetian, C.; Hochedez, J. -F.; Song, X. Y.; Catura, R. C.; Clette, F.; Defise, J. -M.

    2000-01-01

    This paper presents the preflight photometric calibration of the Extreme-ultraviolet Imaging Telescope (EIT) aboard the Solar and Heliospheric Observatory (SOHO). The EIT consists of a Ritchey-Chretien telescope with multilayer coatings applied to four quadrants of the primary and secondary mirrors, several filters and a backside-thinned CCD detector. The quadrants of the EIT optics were used to observe the Sun in 4 wavelength bands that peak near 171, 195, 284, and 304 . Before the launch of SOHO, the EIT mirror reflectivities, the filter transmissivities and the CCD quantum efficiency were measured and these values are described here. The instrumental throughput in terms of an effective area is presented for each of the various mirror quadrant and filter wheel combinations. The response to a coronal plasma as a function of temperature is also determined and the expected count rates are compared to the count rates observed in a coronal hole, the quiet Sun and an active region.

  18. Systematic measurement of fast neutron background fluctuations in an urban area using a mobile detection system

    NASA Astrophysics Data System (ADS)

    Iyengar, A.; Beach, M.; Newby, R. J.; Fabris, L.; Heilbronn, L. H.; Hayward, J. P.

    2015-02-01

    Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee, USA. The 0.5 m2 system, consisting of eight EJ-301 liquid scintillation detectors, was used to collect neutron background measurements in order to better understand the systematic variations in background that depend solely on the street-level measurement position in a downtown area. Data was collected along 5 different streets, and the measurements were found to be repeatable. Using 10-min measurements, the fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reduction in background count rates ranging from 10% to 50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the net shielding of the cosmic ray neutron flux by adjacent buildings. For reference, the building structure as observed at street level is quantified in part here by a measured angle-of-open-sky metric.

  19. Note: Operation of gamma-ray microcalorimeters at elevated count rates using filters with constraints

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alpert, B. K.; Horansky, R. D.; Bennett, D. A.

    Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operationmore » at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.« less

  20. Mealtime Insulin Dosing by Carbohydrate Counting in Hospitalized Cardiology Patients: A Retrospective Cohort Study.

    PubMed

    Thurber, Kristina M; Dierkhising, Ross A; Reiland, Sarah A; Pearson, Kristina K; Smith, Steven A; O'Meara, John G

    2016-01-01

    Carbohydrate counting may improve glycemic control in hospitalized cardiology patients by providing individualized insulin doses tailored to meal consumption. The purpose of this study was to compare glycemic outcomes with mealtime insulin dosed by carbohydrate counting versus fixed dosing in the inpatient setting. This single-center retrospective cohort study included 225 adult medical cardiology patients who received mealtime, basal, and correction-scale insulin concurrently for at least 72 h and up to 7 days in the interval March 1, 2010-November 7, 2013. Mealtime insulin was dosed by carbohydrate counting or with fixed doses determined prior to meal intake. An inpatient diabetes consult service was responsible for insulin management. Exclusion criteria included receipt of an insulin infusion. The primary end point compared mean daily postprandial glucose values, whereas secondary end points included comparison of preprandial glucose values and mean daily rates of hypoglycemia. Mean postprandial glucose level on Day 7 was 204 and 183 mg/dL in the carbohydrate counting and fixed mealtime dose groups, respectively (unadjusted P=0.04, adjusted P=0.12). There were no statistical differences between groups on Days 2-6. Greater rates of preprandial hypoglycemia were observed in the carbohydrate counting cohort on Day 5 (8.6% vs. 1.5%, P=0.02), Day 6 (1.7% vs. 0%, P=0.01), and Day 7 (7.1% vs. 0%, P=0.008). No differences in postprandial hypoglycemia were seen. Mealtime insulin dosing by carbohydrate counting was associated with similar glycemic outcomes as fixed mealtime insulin dosing, except for a greater incidence of preprandial hypoglycemia. Additional comparative studies that include hospital outcomes are needed.

  1. Observer error structure in bull trout redd counts in Montana streams: Implications for inference on true redd numbers

    USGS Publications Warehouse

    Muhlfeld, Clint C.; Taper, Mark L.; Staples, David F.; Shepard, Bradley B.

    2006-01-01

    Despite the widespread use of redd counts to monitor trends in salmonid populations, few studies have evaluated the uncertainties in observed counts. We assessed the variability in redd counts for migratory bull trout Salvelinus confluentus among experienced observers in Lion and Goat creeks, which are tributaries to the Swan River, Montana. We documented substantially lower observer variability in bull trout redd counts than did previous studies. Observer counts ranged from 78% to 107% of our best estimates of true redd numbers in Lion Creek and from 90% to 130% of our best estimates in Goat Creek. Observers made both errors of omission and errors of false identification, and we modeled this combination by use of a binomial probability of detection and a Poisson count distribution of false identifications. Redd detection probabilities were high (mean = 83%) and exhibited no significant variation among observers (SD = 8%). We applied this error structure to annual redd counts in the Swan River basin (1982–2004) to correct for observer error and thus derived more accurate estimates of redd numbers and associated confidence intervals. Our results indicate that bias in redd counts can be reduced if experienced observers are used to conduct annual redd counts. Future studies should assess both sources of observer error to increase the validity of using redd counts for inferring true redd numbers in different basins. This information will help fisheries biologists to more precisely monitor population trends, identify recovery and extinction thresholds for conservation and recovery programs, ascertain and predict how management actions influence distribution and abundance, and examine effects of recovery and restoration activities.

  2. Swift and RXTE follow up observations of the transient currently active in the globular cluster Terzan 5

    NASA Astrophysics Data System (ADS)

    Altamirano, D.; Degenaar, N.; Heinke, C. O.; Homan, J.; Pooley, D.; Sivakoff, G. R.; Wijnands, R.

    2011-10-01

    Following the detection of an X-ray outburst in the direction of Terzan 5 (ATEL #3714), we obtained a Swift observation and additional RXTE observations. The XRT aboard Swift observed Terzan 5 on Oct. 26, 2011 in imaging mode for a total exposure time of 967 s. The source was detected at high count rates causing significant pile-up (the core is saturated), and a bad column intersects the point-spread function.

  3. Cryogenic, high-resolution x-ray detector with high count rate capability

    DOEpatents

    Frank, Matthias; Mears, Carl A.; Labov, Simon E.; Hiller, Larry J.; Barfknecht, Andrew T.

    2003-03-04

    A cryogenic, high-resolution X-ray detector with high count rate capability has been invented. The new X-ray detector is based on superconducting tunnel junctions (STJs), and operates without thermal stabilization at or below 500 mK. The X-ray detector exhibits good resolution (.about.5-20 eV FWHM) for soft X-rays in the keV region, and is capable of counting at count rates of more than 20,000 counts per second (cps). Simple, FET-based charge amplifiers, current amplifiers, or conventional spectroscopy shaping amplifiers can provide the electronic readout of this X-ray detector.

  4. Antarctic meteor observations using the Davis MST and meteor radars

    NASA Astrophysics Data System (ADS)

    Holdsworth, David A.; Murphy, Damian J.; Reid, Iain M.; Morris, Ray J.

    2008-07-01

    This paper presents the meteor observations obtained using two radars installed at Davis (68.6°S, 78.0°E), Antarctica. The Davis MST radar was installed primarily for observation of polar mesosphere summer echoes, with additional transmit and receive antennas installed to allow all-sky interferometric meteor radar observations. The Davis meteor radar performs dedicated all-sky interferometric meteor radar observations. The annual count rate variation for both radars peaks in mid-summer and minimizes in early Spring. The height distribution shows significant annual variation, with minimum (maximum) peak heights and maximum (minimum) height widths in early Spring (mid-summer). Although the meteor radar count rate and height distribution variations are consistent with a similar frequency meteor radar operating at Andenes (69.3°N), the peak heights show a much larger variation than at Andenes, while the count rate maximum-to-minimum ratios show a much smaller variation. Investigation of the effects of the temporal sampling parameters suggests that these differences are consistent with the different temporal sampling strategies used by the Davis and Andenes meteor radars. The new radiant mapping procedure of [Jones, J., Jones, W., Meteor radiant activity mapping using single-station radar observations, Mon. Not. R. Astron. Soc., 367(3), 1050-1056, doi: 10.1111/j.1365-2966.2006.10025.x, 2006] is investigated. The technique is used to detect the Southern delta-Aquarid meteor shower, and a previously unknown weak shower. Meteoroid speeds obtained using the Fresnel transform are presented. The diurnal, annual, and height variation of meteoroid speeds are presented, with the results found to be consistent with those obtained using specular meteor radars. Meteoroid speed estimates for echoes identified as Southern delta-Aquarid and Sextantid meteor candidates show good agreement with the theoretical pre-atmospheric speeds of these showers (41 km s -1 and 32 km s -1, respectively). The meteoroid speeds estimated for these showers show decreasing speed with decreasing height, consistent with the effects of meteoroid deceleration. Finally, we illustrate how the new radiant mapping and meteoroid speed techniques can be combined for unambiguous meteor shower detection, and use these techniques to detect a previously unknown weak shower.

  5. Short-term effects of airborne pollens on asthma attacks as seen by general practitioners in the Greater Paris area, 2003-2007.

    PubMed

    Huynh, Bich Tram; Tual, Séverine; Turbelin, Clément; Pelat, Camille; Cecchi, Lorenzo; D'Amato, Gennaro; Blanchon, Thierry; Annesi-Maesano, Isabella

    2010-09-01

    To investigate for the first time the short-term effects of airborne pollen counts on general practitioner (GP) consultations for asthma attacks in the Greater Paris area between 2003-2007. Counts were available for common pollens (Betula, Cupressa, Fraxinus and Poaceae). Weekly data on GP visits for asthma attacks were obtained from the French GP Sentinel Network. A quasi-Poisson regression with generalised additive models was implemented. Short-term effects of pollen counts were assessed using single and multi-pollen models after adjustment for air pollution and influenza. A mean weekly incidence rate of 25.4 cases of asthma attacks per 100,000 inhabitants was estimated during the study period. The strongest significant association between asthma attacks and pollen counts was registered for grass (Poaceae) in the same week of asthma attacks, with a slight reduction of the effect observed in the multi-pollen model. Adjusted relative risk for Poaceae was 1.54 (95% CI: 1.33-1.79) with an inter-quartile range increase of 17.6 grains/m3 during the pollen season. For the first time, a significant short-term association was observed between Poaceae pollen counts and consultations for asthma attacks as seen by GPs. These findings need to be confirmed by more consistent time-series and investigations on a daily basis.

  6. The Dependence of Tropical Cyclone Count and Size on Rotation Rate

    NASA Astrophysics Data System (ADS)

    Chavas, D. R.; Reed, K. A.

    2017-12-01

    Both theory and idealized equilibrium modeling studies indicate that tropical cyclone size decreases with background rotation rate. In contrast, in real-world observations size tends to increase with latitude. Here we seek to resolve this apparent contradiction via a set of reduced-complexity global aquaplanet simulations with varying planetary rotation rates using the NCAR Community Atmosphere Model 5. The latitudinal distribution of both storm count and size are found to vary markedly with rotation rate, yielding insight into the dynamical constraints on tropical cyclone activity on a rotating planet. Moreover, storm size is found to vary non-monotonically with latitude, indicating that non-equilibrium effects are crucial to the life-cycle evolution of size in nature. Results are then compared to experiments in idealized, time-dependent limited-area modeling simulations using CM1 in axisymmetric and three-dimensional geometry. Taken together, this hierarchy of models is used to quantify the role of equilibrium versus transient controls on storm size and the relevance of each to real storms in nature.

  7. Linear operating region in the ozone dial photon counting system

    NASA Technical Reports Server (NTRS)

    Andrawis, Madeleine

    1995-01-01

    Ozone is a relatively unstable molecule found in Earth's atmosphere. An ozone molecule is made up of three atoms of oxygen. Depending on where ozone resides, it can protect or harm life on Earth. High in the atmosphere, about 15 miles up, ozone acts as a shield to protect Earth's surface from the sun's harmful ultraviolet radiation. Without this shield, we would be more susceptible to skin cancer, cataracts, and impaired immune systems. Closer to Earth, in the air we breathe, ozone is a harmful pollutant that causes damage to lung tissue and plants. Since the early 1980's, airborne lidar systems have been used for making measurements of ozone. The differential absorption lidar (DIAL) technique is used in the remote measurement of O3. This system allows the O3 to be measured as function of the range in the atmosphere. Two frequency-doubled Nd:YAG lasers are used to pump tunable dye lasers. The lasers are operating at 289 nm for the DIAL on-line wavelength of O3, and the other one is operated at 300 nm for the off-line wavelength. The DIAL wavelengths are produced in sequential laser pulses with a time separation of 300 micro s. The backscattered laser energy is collected by telescopes and measured using photon counting systems. The photon counting system measures the light signal by making use of the photon nature of light. The output pulse from the Photo-Multiplier Tube (PE), caused by a photon striking the PMT photo-cathode, is amplified and passed to a pulse height discriminator. The peak value of the pulse is compared to a reference voltage (discrimination level). If the pulse amplitude exceeds the discrimination level, the discriminator generates a standard pulse which is counted by the digital counter. Non-linearity in the system is caused by the overlapping of pulses and the finite response time of the electronics. At low count rates one expects the system to register one event for each output pulse from the PMT corresponding to a photon incident upon the photocathode, however, at higher rates the limitations of the discrimination/counting system will cause the observed count rate to be non-linear with respect to the true count rate. Depending on the pulse height distribution and the discriminator level, the overlapping of pulses (pulse pile-up) can cause count loss or even an additional apparent count gain as the signal levels increase. Characterization of the system, including the pulse height distribution, the signal to noise ratio, and the effect of the discriminator threshold level, is critical in maximizing the linear operating region of the system, thus greatly increasing the useful dynamic range of the system.

  8. Model-free aftershock forecasts constructed from similar sequences in the past

    NASA Astrophysics Data System (ADS)

    van der Elst, N.; Page, M. T.

    2017-12-01

    The basic premise behind aftershock forecasting is that sequences in the future will be similar to those in the past. Forecast models typically use empirically tuned parametric distributions to approximate past sequences, and project those distributions into the future to make a forecast. While parametric models do a good job of describing average outcomes, they are not explicitly designed to capture the full range of variability between sequences, and can suffer from over-tuning of the parameters. In particular, parametric forecasts may produce a high rate of "surprises" - sequences that land outside the forecast range. Here we present a non-parametric forecast method that cuts out the parametric "middleman" between training data and forecast. The method is based on finding past sequences that are similar to the target sequence, and evaluating their outcomes. We quantify similarity as the Poisson probability that the observed event count in a past sequence reflects the same underlying intensity as the observed event count in the target sequence. Event counts are defined in terms of differential magnitude relative to the mainshock. The forecast is then constructed from the distribution of past sequences outcomes, weighted by their similarity. We compare the similarity forecast with the Reasenberg and Jones (RJ95) method, for a set of 2807 global aftershock sequences of M≥6 mainshocks. We implement a sequence-specific RJ95 forecast using a global average prior and Bayesian updating, but do not propagate epistemic uncertainty. The RJ95 forecast is somewhat more precise than the similarity forecast: 90% of observed sequences fall within a factor of two of the median RJ95 forecast value, whereas the fraction is 85% for the similarity forecast. However, the surprise rate is much higher for the RJ95 forecast; 10% of observed sequences fall in the upper 2.5% of the (Poissonian) forecast range. The surprise rate is less than 3% for the similarity forecast. The similarity forecast may be useful to emergency managers and non-specialists when confidence or expertise in parametric forecasting may be lacking. The method makes over-tuning impossible, and minimizes the rate of surprises. At the least, this forecast constitutes a useful benchmark for more precisely tuned parametric forecasts.

  9. SPAD electronics for high-speed quantum communications

    NASA Astrophysics Data System (ADS)

    Bienfang, Joshua C.; Restelli, Alessandro; Migdall, Alan

    2011-01-01

    We discuss high-speed electronics that support the use of single-photon avalanche diodes (SPADs) in gigahertz singlephoton communications systems. For InGaAs/InP SPADs, recent work has demonstrated reduced afterpulsing and count rates approaching 500 MHz can be achieved with gigahertz periodic-gating techniques designed to minimize the total avalanche charge to less than 100 fC. We investigate afterpulsing in this regime and establish a connection to observations using more conventional techniques. For Si SPADs, we report the benefits of improved timing electronics that enhance the temporal resolution of Si SPADs used in a free-space quantum key distribution (QKD) system operating in the GHz regime. We establish that the effects of count-rate fluctuations induced by daytime turbulent scintillation are significantly reduced, benefitting the performance of the QKD system.

  10. The cosmological analysis of X-ray cluster surveys - I. A new method for interpreting number counts

    NASA Astrophysics Data System (ADS)

    Clerc, N.; Pierre, M.; Pacaud, F.; Sadibekova, T.

    2012-07-01

    We present a new method aimed at simplifying the cosmological analysis of X-ray cluster surveys. It is based on purely instrumental observable quantities considered in a two-dimensional X-ray colour-magnitude diagram (hardness ratio versus count rate). The basic principle is that even in rather shallow surveys, substantial information on cluster redshift and temperature is present in the raw X-ray data and can be statistically extracted; in parallel, such diagrams can be readily predicted from an ab initio cosmological modelling. We illustrate the methodology for the case of a 100-deg2XMM survey having a sensitivity of ˜10-14 erg s-1 cm-2 and fit at the same time, the survey selection function, the cluster evolutionary scaling relations and the cosmology; our sole assumption - driven by the limited size of the sample considered in the case study - is that the local cluster scaling relations are known. We devote special attention to the realistic modelling of the count-rate measurement uncertainties and evaluate the potential of the method via a Fisher analysis. In the absence of individual cluster redshifts, the count rate and hardness ratio (CR-HR) method appears to be much more efficient than the traditional approach based on cluster counts (i.e. dn/dz, requiring redshifts). In the case where redshifts are available, our method performs similar to the traditional mass function (dn/dM/dz) for the purely cosmological parameters, but constrains better parameters defining the cluster scaling relations and their evolution. A further practical advantage of the CR-HR method is its simplicity: this fully top-down approach totally bypasses the tedious steps consisting in deriving cluster masses from X-ray temperature measurements.

  11. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel

    PubMed Central

    Viehman, Haley A.

    2017-01-01

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000 in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide. PMID:28493894

  12. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel.

    PubMed

    Viehman, Haley A; Zydlewski, Gayle Barbin

    2017-01-01

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000 in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide.

  13. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel

    DOE PAGES

    Viehman, Haley A.; Zydlewski, Gayle Barbin; Hewitt, Judi

    2017-05-11

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000more » in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide.« less

  14. Multi-scale temporal patterns in fish presence in a high-velocity tidal channel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viehman, Haley A.; Zydlewski, Gayle Barbin; Hewitt, Judi

    The natural variation of fish presence in high-velocity tidal channels is not well understood. A better understanding of fish use of these areas would aid in predicting fish interactions with marine hydrokinetic (MHK) devices, the effects of which are uncertain but of high concern. To characterize the patterns in fish presence at a tidal energy site in Cobscook Bay, Maine, we examined two years of hydroacoustic data continuously collected at the proposed depth of an MHK turbine with a bottom-mounted, side-looking echosounder. The maximum number of fish counted per hour ranged from hundreds in the early spring to over 1,000more » in the fall. Counts varied greatly with tidal and diel cycles in a seasonally changing relationship, likely linked to the seasonally changing fish community of the bay. In the winter and spring, higher hourly counts were generally confined to ebb tides and low slack tides near sunrise and sunset. In summer and fall of each year, the highest fish counts shifted to night and occurred during ebb, low slack, and flood tides. Fish counts were not linked to current speed, and did not decrease as current speed increased, contrary to observations at other tidal power sites. As fish counts may be proportional to the encounter rate of fish with an MHK turbine at the same depth, highly variable counts indicate that the risk to fish is similarly variable. The links between fish presence and environmental cycles at this site will likely be present at other locations with similar environmental forcing, making these observations useful in predicting potential fish interactions at tidal energy sites worldwide.« less

  15. 25 CFR 542.3 - How do I comply with this part?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... provide for drop/count observations, inclusive of hard drop/count, soft drop/count and currency acceptor... observations would be unexpected, the hard count and soft count rooms may be entered simultaneously... should be included in the Agreed-Upon Procedures report transmitted to the Commission. (4) Report Format...

  16. Low- to Middle-Latitude X-Ray Emission from Jupiter

    NASA Technical Reports Server (NTRS)

    Bhardwaj, Anil; Elsner, Ronald F.; Gladstone, G. Randall; Waite, J. Hunter, Jr.; Branduardi-Raymont, Graziella; Cravens, Thomas E.; Ford, Peter G.

    2006-01-01

    The Chandra X-ray Observatory (CXO) observed Jupiter during the period 24-26 February 2003 for approx. 40 hours (4 Jupiter rotations), using both the spectroscopy array of the Advanced CCD Imaging Spectrometer (ACIS-S) and the imaging array of the High-Resolution Camera (HRC-I). Two ACIS-S exposures, each -8.5 hours long, were separated by an HRC-I exposure of approx. 20 hours. The low- to middle-latitude nonauroral disk X-ray emission is much more spatially uniform than the auroral emission. However, the low- to middle-latitude X-ray count rate shows a small but statistically significant hour angle dependence and depends on surface magnetic field strength. In addition, the X-ray spectra from regions corresponding to 3-5 gauss and 5-7 gauss surface fields show significant differences in the energy band 1.26-1.38 keV, perhaps partly due to line emission occurring in the 3-5 gauss region but not the 5-7 gauss region. A similar correlation of surface magnetic field strength with count rate is found for the 18 December 2000 HRC-I data, at a time when solar activity was high. The low- to middle-latitude disk X-ray count rate observed by the HRC-I in the February 2003 observation is about 50% of that observed in December 2000, roughly consistent with a decrease in the solar activity index (F10.7 cm flux) by a similar amount over the same time period. The low- to middle-latitude X-ray emission does not show any oscillations similar to the approx. 45 min oscillations sometimes seen from the northern auroral zone. The temporal variation in Jupiter's nonauroral X-ray emission exhibits similarities to variations in solar X-ray flux observed by GOES and TIMED/SEE. The two ACIS-S 0.3-2.0 keV low- to middle-latitude X-ray spectra are harder than the auroral spectrum and are different from each other at energies above 0.7 keV, showing variability in Jupiter's nonauroral X-ray emission on a timescale of a day. The 0.3-2.0 keV X-ray power emitted at low to middle latitudes is 0.21 GW and 0.39 GW for the first and second ACIS-S exposures, respectively. We suggest that X-ray emission from Jupiter's disk may be largely generated by the scattering and fluorescence of solar X rays in its upper atmosphere, especially at times of high incident solar X-ray flux. However, the dependence of count rate on surface magnetic-field strength may indicate the presence of some secondary component, possibly ion precipitation from radiation belts close to the planet.

  17. Low- to Mid-Latitude X-Ray Emission from Jupiter

    NASA Technical Reports Server (NTRS)

    Bhardwaj, Anil; Elsner, Ronald F.; Gladstone, G. Randall; Waite, J. Hunter, Jr.; Branduardi-Raymont, Graziella; Cravens, Thomas E.; Ford, Peter

    2006-01-01

    The Chandra X-ray Observatory (CXO) observed Jupiter during the period 2003 February 24-26 for approx.40 hours (4 Jupiter rotations), using both the spectroscopy array of the Advanced CCD Imaging Spectrometer (ACIS-S) and the imaging array of the High-Resolution Camera (HRC-I). Two ACIS-S exposures, each approx.8.5 hr long, were separated by an HRC-I exposure of approx.20 hr. The low- to mid-latitude non-auroral disk X-ray emission is much more spatially uniform than the auroral emission. However, the low- to mid-latitude X-ray count rate shows a small but statistically significant hour angle dependence, and is higher in regions of relatively low surface magnetic field strength, confirming ROSAT results. In addition, the spectrum from the low surface field region shows an enhancement in the energy band 1.14- 1.38 keV, perhaps partly due to line emission from that region. Correlation of surface magnetic field strength with count rate is not found for the 2000 December HRC-I data, at a time when solar activity was high. The low- to mid-latitude disk X-ray count rate observed by the HRC-I in the 2003 February observation is about 50% of that observed in 2000 December, roughly consistent with a decrease in the solar activity index (F10.7 cm flux) by a similar amount over the same time period. The low- to mid-latitude X-ray emission does not show any oscillations similar to the -45 minute oscillations sometimes seen from the northern auroral zone. The temporal variation in Jupiter's non-auroral X-ray emission exhibits similarities to variations in solar X-ray flux observed by GOES and TIMED/SEE. The two ACIS-S 0.3-2 keV low- to mid-latitude X-ray spectra are harder than the auroral spectrum, and are different from each other at energies above 0.7 keV, showing variability in Jupiter s non-auroral X-ray emission on a time scale of a day. The 0.3-2.0 keV X-ray power emitted at low- to mid-latitudes is 0.21 GW and 0.39 GW for the first and second ACIS-S exposures, respectively. We suggest that X-ray emission from Jupiter's disk may be largely generated by solar X-rays resonantly and fluorescently scattered in its upper atmosphere, especially at times of high incident solar X-ray flux. However, the correlation of higher count rate with low surface magnetic-field strength indicates the presence of some secondary component, possibly ion precipitation from radiation belts closer to the planet than elsewhere at low- to mid-latitudes.

  18. Kids Count in Indiana: 1996 Data Book.

    ERIC Educational Resources Information Center

    Erickson, Judith B.

    This Kids Count report is the third in a series examining statewide trends in the well-being of Indiana's children. The report combines statistics of special concern in Indiana with 10 national Kids Count well-being indicators: (1) percent low birthweight; (2) infant mortality rate; (3) child death rate; (4) birth rate to unmarried teens ages 15…

  19. Wireless, in-vessel neutron monitor for initial core-loading of advanced breeder reactors

    NASA Technical Reports Server (NTRS)

    Delorenzo, J. T.; Kennedy, E. J.; Blalock, T. V.; Rochelle, J. M.; Chiles, M. M.; Valentine, K. H.

    1981-01-01

    An experimental wireless, in-vessel neutron monitor was developed to measure the reactivity of an advanced breeder reactor as the core is loaded for the first time to preclude an accidental critically incident. The environment is liquid sodium at a temperature of approx. 220 C, with negligible gamma or neutron radiation. With ultrasonic transmission of neutron data, no fundamental limitation was observed after tests at 230 C for 2000 h. The neutron sensitivity was approx. 1 count/s-nv, and the potential data transmission rate was approx. 10,000 counts/s.

  20. 333 E. Ontario, Nov. 2011, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    No count rates were observed at any time that exceeded the USEPA’s threshold limit of 18,728 cpm for the 2”x2” 44-10 Sodium Iodide (NaI)probe. Based on the findings of the surface scan, no areas of elevated thorium concentrationswere identified.

  1. OBSERVATION OF THE RADIATION ANOMALIES AT THE ALTITUDES OF 200-300 KM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ginzburg, V.L.; Kurnosova, L.V.; Logachev, V.I.

    1962-01-01

    Radiation measurements from Sputnik V (310 to 330 km) and Sputnik VI (190 to 260 km) in the latitude range -65 deg to 65 deg are shown. The South Atlantic and South anomalies are discussed, and counting rate changes are shown. (W.D.M.)

  2. Development and application of nanoparticles synthesized with folic acid-conjugated soy protein

    USDA-ARS?s Scientific Manuscript database

    In this study, soy protein isolate (SPI) was conjugated with folic acid (FA) to prepare nanoparticles for target-specific drug delivery. Successful conjugation was evidenced by UV spectrophotometry and primary amino group analysis. An increase in count rate by at least 142% was observed in FA-conjug...

  3. Effects of Nitrogen Availability and Form on Phytoplankton Growth in a Eutrophied Estuary (Neuse River Estuary, NC, USA).

    PubMed

    Cira, Emily K; Paerl, Hans W; Wetz, Michael S

    2016-01-01

    Nitrogen availability and form are important controls on estuarine phytoplankton growth. This study experimentally determined the influence of urea and nitrate additions on phytoplankton growth throughout the growing season (March 2012, June 2011, August 2011) in a temperate, eutrophied estuary (Neuse River Estuary, North Carolina, USA). Photopigments (chlorophyll a and diagnostic photopigments: peridinin, fucoxanthin, alloxanthin, zeaxanthin, chlorophyll b) and microscopy-based cell counts were used as indicators of phytoplankton growth. In March, the phytoplankton community was dominated by Gyrodinium instriatum and only fucoxanthin-based growth rates were stimulated by nitrogen addition. The limited response to nitrogen suggests other factors may control phytoplankton growth and community composition in early spring. In June, inorganic nitrogen concentrations were low and stimulatory effects of both nitrogen forms were observed for chlorophyll a- and diagnostic photopigment-based growth rates. In contrast, cell counts showed that only cryptophyte and dinoflagellate (Heterocapsa rotundata) growth were stimulated. Responses of other photopigments may have been due to an increase in pigment per cell or growth of plankton too small to be counted with the microscopic methods used. Despite high nitrate concentrations in August, growth rates were elevated in response to urea and/or nitrate addition for all photopigments except peridinin. However, this response was not observed in cell counts, again suggesting that pigment-based growth responses may not always be indicative of a true community and/or taxa-specific growth response. This highlights the need to employ targeted microscopy-based cell enumeration concurrent with pigment-based technology to facilitate a more complete understanding of phytoplankton dynamics in estuarine systems. These results are consistent with previous studies showing the seasonal importance of nitrogen availability in estuaries, and also reflect taxa-specific responses nitrogen availability. Finally, this study demonstrates that under nitrogen-limiting conditions, the phytoplankton community and its various taxa are capable of using both urea and nitrate to support growth.

  4. Effects of Nitrogen Availability and Form on Phytoplankton Growth in a Eutrophied Estuary (Neuse River Estuary, NC, USA)

    PubMed Central

    Paerl, Hans W.; Wetz, Michael S.

    2016-01-01

    Nitrogen availability and form are important controls on estuarine phytoplankton growth. This study experimentally determined the influence of urea and nitrate additions on phytoplankton growth throughout the growing season (March 2012, June 2011, August 2011) in a temperate, eutrophied estuary (Neuse River Estuary, North Carolina, USA). Photopigments (chlorophyll a and diagnostic photopigments: peridinin, fucoxanthin, alloxanthin, zeaxanthin, chlorophyll b) and microscopy-based cell counts were used as indicators of phytoplankton growth. In March, the phytoplankton community was dominated by Gyrodinium instriatum and only fucoxanthin-based growth rates were stimulated by nitrogen addition. The limited response to nitrogen suggests other factors may control phytoplankton growth and community composition in early spring. In June, inorganic nitrogen concentrations were low and stimulatory effects of both nitrogen forms were observed for chlorophyll a- and diagnostic photopigment-based growth rates. In contrast, cell counts showed that only cryptophyte and dinoflagellate (Heterocapsa rotundata) growth were stimulated. Responses of other photopigments may have been due to an increase in pigment per cell or growth of plankton too small to be counted with the microscopic methods used. Despite high nitrate concentrations in August, growth rates were elevated in response to urea and/or nitrate addition for all photopigments except peridinin. However, this response was not observed in cell counts, again suggesting that pigment-based growth responses may not always be indicative of a true community and/or taxa-specific growth response. This highlights the need to employ targeted microscopy-based cell enumeration concurrent with pigment-based technology to facilitate a more complete understanding of phytoplankton dynamics in estuarine systems. These results are consistent with previous studies showing the seasonal importance of nitrogen availability in estuaries, and also reflect taxa-specific responses nitrogen availability. Finally, this study demonstrates that under nitrogen-limiting conditions, the phytoplankton community and its various taxa are capable of using both urea and nitrate to support growth. PMID:27504970

  5. The silicon drift detector for the IXO high-time resolution spectrometer

    NASA Astrophysics Data System (ADS)

    Lechner, Peter; Amoros, Carine; Barret, Didier; Bodin, Pierre; Boutelier, Martin; Eckhardt, Rouven; Fiorini, Carlo; Kendziorra, Eckhard; Lacombe, Karine; Niculae, Adrian; Pouilloux, Benjamin; Pons, Roger; Rambaud, Damien; Ravera, Laurent; Schmid, Christian; Soltau, Heike; Strüder, Lothar; Tenzer, Christoph; Wilms, Jörn

    2010-07-01

    The High Time Resolution Spectrometer (HTRS) is one of six scientific payload instruments of the International X-ray Observatory (IXO). HTRS is dedicated to the physics of matter at extreme density and gravity and will observe the X-rays generated in the inner accretion flows around the most compact massive objects, i.e. black holes and neutron stars. The study of their timing signature and in addition the simultaneous spectroscopy of the gravitationally shifted and broadened iron line allows for probing general relativity in the strong field regime and understanding the inner structure of neutron stars. As the sources to be observed by HTRS are the brightest in the X-ray sky and the studies require good photon statistics the instrument design is driven by the capability to operate at extremely high count rates. The HTRS instrument is based on a monolithic array of Silicon Drift Detectors (SDDs) with 31 cells in a circular envelope and a sensitive volume of 4.5 cm2 × 450 μm. The SDD principle uses fast signal charge collection on an integrated amplifier by a focusing internal electrical field. It combines a large sensitive area and a small capacitance, thus facilitating good energy resolution and high count rate capability. The HTRS is specified to provide energy spectra with a resolution of 150 eV (FWHM at 6 keV) at high time resolution of 10 μsec and with high count rate capability up to a goal of 2.106 counts per second, corresponding to a 12 Crab equivalent source. As the HTRS is a non-imaging instrument and will target only point sources it is placed on axis but out of focus so that the spot is spread over the array of 31 SDD cells. The SDD array is logically organized in four independent 'quadrants', a dedicated 8-channel quadrant readout chip is in development.

  6. Group B streptococcus colonization and HIV in pregnancy: A cohort study in Nigeria.

    PubMed

    Biobaku Oluwafunmilola, R; Olaleye Atinuke, O; Adefusi Olorunwa, F; Adeyemi Babalola, A; Onipede Anthony, O; Loto Olabisi, M; Imaralu John, O

    2017-01-01

    Group B streptococcus (GBS) is a leading cause of maternal and neonatal infectious morbidity. HIV is prevalent among pregnant women in Nigeria. To determine the rates of anogenital GBS colonization in our institution and compare GBS colonization rates between HIV positive and negative pregnant women. A cross-sectional comparative study was conducted over 6 months. Patients were separated according to their HIV status: positive and negative. GBS colonization was assessed by vaginal and anal swabs collected at 35-37 weeks of gestation and cultured in Todd-Hewitt broth, followed by a confirmatory test. Socio-demographic characteristics and CD4 count were extracted from patient medical records. Secondary outcomes were identification of risk factors for GBS colonization, antibiotic sensitivity, and any association between CD4 count and GBS colonization. Appropriate statistical analysis was done. A total of 200 patients attended the clinic; 67 HIV positive and 133 negative. Analyzed samples were 198; the overall prevalence of GBS was 18.2%. No significant difference in GBS colonization was noted between HIV positive (19.4% [13]) and negative patients (17.6% [23/131]). Most GBS isolates were susceptible to ampicillin (87%) and penicillin (81%). A high body mass index (BMI) was independently associated with GBS colonization (OR = 1.25, 95% CI: 1.04-1.51). No association was observed between CD4 counts and GBS colonization. A high prevalence of GBS colonization was observed in our institution. Colonization rates were independent of the HIV status but associated with a high BMI in HIV positive women.

  7. Bondi Accretion and the Problem of the Missing Isolated Neutron Stars

    NASA Technical Reports Server (NTRS)

    Perna, Rosalba; Narayan, Ramesh; Rybicki, George; Stella, Luigi; Treves, Aldo

    2003-01-01

    A large number of neutron stars (NSs), approximately 10(exp 9), populate the Galaxy, but only a tiny fraction of them is observable during the short radio pulsar lifetime. The majority of these isolated NSs, too cold to be detectable by their own thermal emission, should be visible in X-rays as a result of accretion from the interstellar medium. The ROSAT All-Sky Survey has, however, shown that such accreting isolated NSs are very elusive: only a few tentative candidates have been identified, contrary to theoretical predictions that up to several thousand should be seen. We suggest that the fundamental reason for this discrepancy lies in the use of the standard Bondi formula to estimate the accretion rates. We compute the expected source counts using updated estimates of the pulsar velocity distribution, realistic hydrogen atmosphere spectra, and a modified expression for the Bondi accretion rate, as suggested by recent MHD simulations and supported by direct observations in the case of accretion around supermassive black holes in nearby galaxies and in our own. We find that, whereas the inclusion of atmospheric spectra partly compensates for the reduction in the counts due to the higher mean velocities of the new distribution, the modified Bondi formula dramatically suppresses the source counts. The new predictions are consistent with a null detection at the ROSAT sensitivity.

  8. Photon counting spectral breast CT: effect of adaptive filtration on CT numbers, noise, and contrast to noise ratio.

    PubMed

    Silkwood, Justin D; Matthews, Kenneth L; Shikhaliev, Polad M

    2013-05-01

    Photon counting spectral (PCS) computed tomography (CT) shows promise for breast imaging. An issue with current photon-counting detectors is low count rate capabilities, artifacts resulting from nonuniform count rate across the field of view, and suboptimal spectral information. These issues are addressed in part by using tissue-equivalent adaptive filtration of the x-ray beam. The purpose of the study was to investigate the effect of adaptive filtration on different aspects of PCS breast CT. The theoretical formulation for the filter shape was derived for different filter materials and evaluated by simulation and an experimental prototype of the filter was fabricated from a tissue-like material (acrylic). The PCS CT images of a glandular breast phantom with adipose and iodine contrast elements were simulated at 40, 60, 90, and 120 kVp tube voltages, with and without adaptive filter. The CT numbers, CT noise, and contrast-to-noise ratio (CNR) were compared for spectral CT images acquired with and without adaptive filters. Similar comparison was made for material-decomposed PCS CT images. The adaptive filter improved the uniformity of CT numbers, CT noise, and CNR in both ordinary and material decomposed PCS CT images. At the same tube output the average CT noise with adaptive filter, although uniform, was higher than the average noise without adaptive filter due to x-ray absorption by the filter. Increasing tube output, so that average skin exposure with the adaptive filter was same as without filter, made the noise with adaptive filter comparable to or lower than that without adaptive filter. Similar effects were observed when energy weighting was applied, and when material decompositions were performed using energy selective CT data. An adaptive filter decreases count rate requirements to the photon counting detectors which enables PCS breast CT based on commercially available detector technologies. Adaptive filter also improves image quality in PCS breast CT by decreasing beam hardening artifacts and by eliminating spatial nonuniformities of CT numbers, noise, and CNR.

  9. Testing the Accuracy of Aerial Surveys for Large Mammals: An Experiment with African Savanna Elephants (Loxodonta africana).

    PubMed

    Schlossberg, Scott; Chase, Michael J; Griffin, Curtice R

    2016-01-01

    Accurate counts of animals are critical for prioritizing conservation efforts. Past research, however, suggests that observers on aerial surveys may fail to detect all individuals of the target species present in the survey area. Such errors could bias population estimates low and confound trend estimation. We used two approaches to assess the accuracy of aerial surveys for African savanna elephants (Loxodonta africana) in northern Botswana. First, we used double-observer sampling, in which two observers make observations on the same herds, to estimate detectability of elephants and determine what variables affect it. Second, we compared total counts, a complete survey of the entire study area, against sample counts, in which only a portion of the study area is sampled. Total counts are often considered a complete census, so comparing total counts against sample counts can help to determine if sample counts are underestimating elephant numbers. We estimated that observers detected only 76% ± SE of 2% of elephant herds and 87 ± 1% of individual elephants present in survey strips. Detectability increased strongly with elephant herd size. Out of the four observers used in total, one observer had a lower detection probability than the other three, and detectability was higher in the rear row of seats than the front. The habitat immediately adjacent to animals also affected detectability, with detection more likely in more open habitats. Total counts were not statistically distinguishable from sample counts. Because, however, the double-observer samples revealed that observers missed 13% of elephants, we conclude that total counts may be undercounting elephants as well. These results suggest that elephant population estimates from both sample and total counts are biased low. Because factors such as observer and habitat affected detectability of elephants, comparisons of elephant populations across time or space may be confounded. We encourage survey teams to incorporate detectability analysis in all aerial surveys for mammals.

  10. Testing the Accuracy of Aerial Surveys for Large Mammals: An Experiment with African Savanna Elephants (Loxodonta africana)

    PubMed Central

    Schlossberg, Scott; Chase, Michael J.; Griffin, Curtice R.

    2016-01-01

    Accurate counts of animals are critical for prioritizing conservation efforts. Past research, however, suggests that observers on aerial surveys may fail to detect all individuals of the target species present in the survey area. Such errors could bias population estimates low and confound trend estimation. We used two approaches to assess the accuracy of aerial surveys for African savanna elephants (Loxodonta africana) in northern Botswana. First, we used double-observer sampling, in which two observers make observations on the same herds, to estimate detectability of elephants and determine what variables affect it. Second, we compared total counts, a complete survey of the entire study area, against sample counts, in which only a portion of the study area is sampled. Total counts are often considered a complete census, so comparing total counts against sample counts can help to determine if sample counts are underestimating elephant numbers. We estimated that observers detected only 76% ± SE of 2% of elephant herds and 87 ± 1% of individual elephants present in survey strips. Detectability increased strongly with elephant herd size. Out of the four observers used in total, one observer had a lower detection probability than the other three, and detectability was higher in the rear row of seats than the front. The habitat immediately adjacent to animals also affected detectability, with detection more likely in more open habitats. Total counts were not statistically distinguishable from sample counts. Because, however, the double-observer samples revealed that observers missed 13% of elephants, we conclude that total counts may be undercounting elephants as well. These results suggest that elephant population estimates from both sample and total counts are biased low. Because factors such as observer and habitat affected detectability of elephants, comparisons of elephant populations across time or space may be confounded. We encourage survey teams to incorporate detectability analysis in all aerial surveys for mammals. PMID:27755570

  11. Many participants in inpatient rehabilitation can quantify their exercise dosage accurately: an observational study.

    PubMed

    Scrivener, Katharine; Sherrington, Catherine; Schurr, Karl; Treacy, Daniel

    2011-01-01

    Are inpatients undergoing rehabilitation who appear able to count exercises able to quantify accurately the amount of exercise they undertake? Observational study. Inpatients in an aged care rehabilitation unit and a neurological rehabilitation unit, who appeared able to count their exercises during a 1-2 min observation by their treating physiotherapist. Participants were observed for 30 min by an external observer while they exercised in the physiotherapy gymnasium. Both the participants and the observer counted exercise repetitions with a hand-held tally counter and the two tallies were compared. Of the 60 people admitted for aged care rehabilitation during the study period, 49 (82%) were judged by their treating therapist to be able to count their own exercise repetitions accurately. Of the 30 people admitted for neurological rehabilitation during the study period, 20 (67%) were judged by their treating therapist to be able to count their repetitions accurately. Of the 69 people judged to be accurate, 40 underwent observation while exercising. There was excellent agreement between these participants' counts of their exercise repetitions and the observers' counts, ICC (3,1) of 0.99 (95% CI 0.98 to 0.99). Eleven participants (28%) were in complete agreement with the observer. A further 19 participants (48%) varied from the observer by less than 10%. Therapists were able to identify a group of rehabilitation participants who were accurate in counting their exercise repetitions. Counting of exercise repetitions by therapist-selected patients is a valid means of quantifying exercise dosage during inpatient rehabilitation. Copyright © 2011 Australian Physiotherapy Association. Published by .. All rights reserved.

  12. Counting-loss correction for X-ray spectroscopy using unit impulse pulse shaping.

    PubMed

    Hong, Xu; Zhou, Jianbin; Ni, Shijun; Ma, Yingjie; Yao, Jianfeng; Zhou, Wei; Liu, Yi; Wang, Min

    2018-03-01

    High-precision measurement of X-ray spectra is affected by the statistical fluctuation of the X-ray beam under low-counting-rate conditions. It is also limited by counting loss resulting from the dead-time of the system and pile-up pulse effects, especially in a high-counting-rate environment. In this paper a detection system based on a FAST-SDD detector and a new kind of unit impulse pulse-shaping method is presented, for counting-loss correction in X-ray spectroscopy. The unit impulse pulse-shaping method is evolved by inverse deviation of the pulse from a reset-type preamplifier and a C-R shaper. It is applied to obtain the true incoming rate of the system based on a general fast-slow channel processing model. The pulses in the fast channel are shaped to unit impulse pulse shape which possesses small width and no undershoot. The counting rate in the fast channel is corrected by evaluating the dead-time of the fast channel before it is used to correct the counting loss in the slow channel.

  13. Population dose-response analysis of daily seizure count following vigabatrin therapy in adult and pediatric patients with refractory complex partial seizures.

    PubMed

    Nielsen, Jace C; Hutmacher, Matthew M; Wesche, David L; Tolbert, Dwain; Patel, Mahlaqa; Kowalski, Kenneth G

    2015-01-01

    Vigabatrin is an irreversible inhibitor of γ-aminobutyric acid transaminase (GABA-T) and is used as an adjunctive therapy for adult patients with refractory complex partial seizures (rCPS). The purpose of this investigation was to describe the relationship between vigabatrin dosage and daily seizure rate for adults and children with rCPS and identify relevant covariates that might impact seizure frequency. This population dose-response analysis used seizure-count data from three pediatric and two adult randomized controlled studies of rCPS patients. A negative binomial distribution model adequately described daily seizure data. Mean seizure rate decreased with time after first dose and was described using an asymptotic model. Vigabatrin drug effects were best characterized by a quadratic model using normalized dosage as the exposure metric. Normalized dosage was an estimated parameter that allowed for individualized changes in vigabatrin exposure based on body weight. Baseline seizure rate increased with decreasing age, but age had no impact on vigabatrin drug effects after dosage was normalized for body weight differences. Posterior predictive checks indicated the final model was capable of simulating data consistent with observed daily seizure counts. Total normalized vigabatrin dosages of 1, 3, and 6 g/day were predicted to reduce seizure rates 23.2%, 45.6%, and 48.5%, respectively. © 2014, The American College of Clinical Pharmacology.

  14. Digital computing cardiotachometer

    NASA Technical Reports Server (NTRS)

    Smith, H. E.; Rasquin, J. R.; Taylor, R. A. (Inventor)

    1973-01-01

    A tachometer is described which instantaneously measures heart rate. During the two intervals between three succeeding heart beats, the electronic system: (1) measures the interval by counting cycles from a fixed frequency source occurring between the two beats; and (2) computes heat rate during the interval between the next two beats by counting the number of times that the interval count must be counted to zero in order to equal a total count of sixty times (to convert to beats per minute) the frequency of the fixed frequency source.

  15. Estimation of low-level neutron dose-equivalent rate by using extrapolation method for a curie level Am-Be neutron source.

    PubMed

    Li, Gang; Xu, Jiayun; Zhang, Jie

    2015-01-01

    Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am-Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am-Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Statistical Parameter Study of the Time Interval Distribution for Nonparalyzable, Paralyzable, and Hybrid Dead Time Models

    NASA Astrophysics Data System (ADS)

    Syam, Nur Syamsi; Maeng, Seongjin; Kim, Myo Gwang; Lim, Soo Yeon; Lee, Sang Hoon

    2018-05-01

    A large dead time of a Geiger Mueller (GM) detector may cause a large count loss in radiation measurements and consequently may cause distortion of the Poisson statistic of radiation events into a new distribution. The new distribution will have different statistical parameters compared to the original distribution. Therefore, the variance, skewness, and excess kurtosis in association with the observed count rate of the time interval distribution for well-known nonparalyzable, paralyzable, and nonparalyzable-paralyzable hybrid dead time models of a Geiger Mueller detector were studied using Monte Carlo simulation (GMSIM). These parameters were then compared with the statistical parameters of a perfect detector to observe the change in the distribution. The results show that the behaviors of the statistical parameters for the three dead time models were different. The values of the skewness and the excess kurtosis of the nonparalyzable model are equal or very close to those of the perfect detector, which are ≅2 for skewness, and ≅6 for excess kurtosis, while the statistical parameters in the paralyzable and hybrid model obtain minimum values that occur around the maximum observed count rates. The different trends of the three models resulting from the GMSIM simulation can be used to distinguish the dead time behavior of a GM counter; i.e. whether the GM counter can be described best by using the nonparalyzable, paralyzable, or hybrid model. In a future study, these statistical parameters need to be analyzed further to determine the possibility of using them to determine a dead time for each model, particularly for paralyzable and hybrid models.

  17. Current CD4 cell count and the short-term risk of AIDS and death before the availability of effective antiretroviral therapy in HIV-infected children and adults.

    PubMed

    Dunn, David; Woodburn, Patrick; Duong, Trinh; Peto, Julian; Phillips, Andrew; Gibb, Di; Porter, Kholoud

    2008-02-01

    Currently, there are no comparable estimates of the short-term risk of disease progression in the absence of effective antiretroviral therapy for human immunodeficiency virus (HIV)-infected adults and children. A joint analysis of 2 large studies of children with vertically acquired HIV infection (the HIV Paediatric Prognostic Markers Collaborative Study) and adults with seroconversion (the CASCADE [Concerted Action on Sero-Conversion to AIDS and Death in Europe] collaboration) was conducted. Follow-up was censored at the end of 1995, before the introduction of combination antiretroviral therapy. The incidence rates of death and AIDS or death (AIDS/death) were estimated on the basis of age and current CD4 cell count. A total of 1260 deaths (over 20,500 person-years of follow-up) and 1894 initial AIDS events (over 17,200 person-years of follow-up) were observed among 6741 patients (3244 children [i.e., patients < or =15 years of age] and 3497 adults). Young children (age, <5 years) experienced high morbidity and mortality rates. After adjustment for the CD4 cell count, the effect of age on disease progression was not significant among older children, whereas the risk increased markedly in association with increasing age among adults. Death rates were similar among older children and adults aged approximately 20 years, as were the rates of progression to AIDS/death when cases of serious recurrent bacterial infection, which has a more restrictive case definition in adults, were excluded. Similar CD4 cell count criteria for initiation of antiretroviral therapy can be applied to adults and children > or = 5 years of age.

  18. A physics investigation of deadtime losses in neutron counting at low rates with Cf252

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Louise G; Croft, Stephen

    2009-01-01

    {sup 252}Cf spontaneous fission sources are used for the characterization of neutron counters and the determination of calibration parameters; including both neutron coincidence counting (NCC) and neutron multiplicity deadtime (DT) parameters. Even at low event rates, temporally-correlated neutron counting using {sup 252}Cf suffers a deadtime effect. Meaning that in contrast to counting a random neutron source (e.g. AmLi to a close approximation), DT losses do not vanish in the low rate limit. This is because neutrons are emitted from spontaneous fission events in time-correlated 'bursts', and are detected over a short period commensurate with their lifetime in the detector (characterizedmore » by the system die-away time, {tau}). Thus, even when detected neutron events from different spontaneous fissions are unlikely to overlap in time, neutron events within the detected 'burst' are subject to intrinsic DT losses. Intrinsic DT losses for dilute Pu will be lower since the multiplicity distribution is softer, but real items also experience self-multiplication which can increase the 'size' of the bursts. Traditional NCC DT correction methods do not include the intrinsic (within burst) losses. We have proposed new forms of the traditional NCC Singles and Doubles DT correction factors. In this work, we apply Monte Carlo neutron pulse train analysis to investigate the functional form of the deadtime correction factors for an updating deadtime. Modeling is based on a high efficiency {sup 3}He neutron counter with short die-away time, representing an ideal {sup 3}He based detection system. The physics of dead time losses at low rates is explored and presented. It is observed that new forms are applicable and offer more accurate correction than the traditional forms.« less

  19. A double-observer approach for estimating detection probability and abundance from point counts

    USGS Publications Warehouse

    Nichols, J.D.; Hines, J.E.; Sauer, J.R.; Fallon, F.W.; Fallon, J.E.; Heglund, P.J.

    2000-01-01

    Although point counts are frequently used in ornithological studies, basic assumptions about detection probabilities often are untested. We apply a double-observer approach developed to estimate detection probabilities for aerial surveys (Cook and Jacobson 1979) to avian point counts. At each point count, a designated 'primary' observer indicates to another ('secondary') observer all birds detected. The secondary observer records all detections of the primary observer as well as any birds not detected by the primary observer. Observers alternate primary and secondary roles during the course of the survey. The approach permits estimation of observer-specific detection probabilities and bird abundance. We developed a set of models that incorporate different assumptions about sources of variation (e.g. observer, bird species) in detection probability. Seventeen field trials were conducted, and models were fit to the resulting data using program SURVIV. Single-observer point counts generally miss varying proportions of the birds actually present, and observer and bird species were found to be relevant sources of variation in detection probabilities. Overall detection probabilities (probability of being detected by at least one of the two observers) estimated using the double-observer approach were very high (>0.95), yielding precise estimates of avian abundance. We consider problems with the approach and recommend possible solutions, including restriction of the approach to fixed-radius counts to reduce the effect of variation in the effective radius of detection among various observers and to provide a basis for using spatial sampling to estimate bird abundance on large areas of interest. We believe that most questions meriting the effort required to carry out point counts also merit serious attempts to estimate detection probabilities associated with the counts. The double-observer approach is a method that can be used for this purpose.

  20. Swift XRT observation of HETE J1900.1-2455

    NASA Astrophysics Data System (ADS)

    Campana, S.

    2005-06-01

    Sergio Campana (INAF-OAB), Antonino Cucchiara (PSU) and Dave Burrows (PSU) on behalf of the XRT team report that Swift observed the seventh millisecond X-ray pulsar HETE J1900.1-2455 on 2005-06-24 UT21:03:37 for 1329 s in a single orbit. The source is bright an is observed in Window Timing (WT) mode, therefore not providing an image. The source count rate in the 0.5-10 keV energy band is 14.9+/-0.1 c/s.

  1. Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

    NASA Technical Reports Server (NTRS)

    Gridley, D. S.; Pecaut, M. J.; Miller, G. M.; Moyers, M. F.; Nelson, G. A.

    2001-01-01

    The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

  2. Pneumotachometer counts respiration rate of human subject

    NASA Technical Reports Server (NTRS)

    Graham, O.

    1964-01-01

    To monitor breaths per minute, two rate-to-analog converters are alternately used to read and count the respiratory rate from an impedance pneumograph sequentially displayed numerically on electroluminescent matrices.

  3. Radiation dosimetry measurements with real time radiation monitoring device (RRMD)-II in Space Shuttle STS-79

    NASA Technical Reports Server (NTRS)

    Sakaguchi, T.; Doke, T.; Hayashi, T.; Kikuchi, J.; Hasebe, N.; Kashiwagi, T.; Takashima, T.; Takahashi, K.; Nakano, T.; Nagaoka, S.; hide

    1997-01-01

    The real-time measurement of radiation environment was made with an improved real-time radiation monitoring device (RRMD)-II onboard Space Shuttle STS-79 (S/MM#4: 4th Shuttle MIR Mission, at an inclination angle of 51.6 degrees and an altitude of 250-400km) for 199 h during 17-25 September, 1996. The observation of the detector covered the linear energy transfer (LET) range of 3.5-6000 keV/micrometer. The Shuttle orbital profile in this mission was equivalent to that of the currently planned Space Station, and provided an opportunity to investigate variations in count rate and dose equivalent rate depending on altitude, longitude, and latitude in detail. Particle count rate and dose equivalent rate were mapped geographically during the mission. Based on the map of count rate, an analysis was made by dividing whole region into three regions: South Atlantic Anomaly (SAA) region, high latitude region and other regions. The averaged absorbed dose rate during the mission was 39.3 microGy/day for a LET range of 3.5-6000 keV/micrometer. The corresponding average dose equivalent rates during the mission are estimated to be 293 microSv/day with quality factors from International Commission on Radiological Protection (ICRP)-Pub. 60 and 270 microSv/day with quality factors from ICRP-Pub. 26. The effective quality factors for ICRP-Pub. 60 and 26 are 7.45 and 6.88, respectively. From the present data for particles of LET > 3.5keV/micrometer, we conclude that the average dose equivalent rate is dominated by the contribution of galactic cosmic ray (GCR) particles. The dose-detector depth dependence was also investigated.

  4. An integrated modeling approach to estimating Gunnison Sage-Grouse population dynamics: combining index and demographic data.

    USGS Publications Warehouse

    Davis, Amy J.; Hooten, Mevin B.; Phillips, Michael L.; Doherty, Paul F.

    2014-01-01

    Evaluation of population dynamics for rare and declining species is often limited to data that are sparse and/or of poor quality. Frequently, the best data available for rare bird species are based on large-scale, population count data. These data are commonly based on sampling methods that lack consistent sampling effort, do not account for detectability, and are complicated by observer bias. For some species, short-term studies of demographic rates have been conducted as well, but the data from such studies are typically analyzed separately. To utilize the strengths and minimize the weaknesses of these two data types, we developed a novel Bayesian integrated model that links population count data and population demographic data through population growth rate (λ) for Gunnison sage-grouse (Centrocercus minimus). The long-term population index data available for Gunnison sage-grouse are annual (years 1953–2012) male lek counts. An intensive demographic study was also conducted from years 2005 to 2010. We were able to reduce the variability in expected population growth rates across time, while correcting for potential small sample size bias in the demographic data. We found the population of Gunnison sage-grouse to be variable and slightly declining over the past 16 years.

  5. A case study of the impact of inaccurate cause-of-death reporting on health disparity tracking: New York City premature cardiovascular mortality.

    PubMed

    Johns, Lauren E; Madsen, Ann M; Maduro, Gil; Zimmerman, Regina; Konty, Kevin; Begier, Elizabeth

    2013-04-01

    Heart disease death overreporting is problematic in New York City (NYC) and other US jurisdictions. We examined whether overreporting affects the premature (< 65 years) heart disease death rate disparity between non-Hispanic Blacks and non-Hispanic Whites in NYC. We identified overreporting hospitals and used counts of premature heart disease deaths at reference hospitals to estimate corrected counts. We then corrected citywide, age-adjusted premature heart disease death rates among Blacks and Whites and a White-Black premature heart disease death disparity. At overreporting hospitals, 51% of the decedents were White compared with 25% at reference hospitals. Correcting the heart disease death counts at overreporting hospitals decreased the age-adjusted premature heart disease death rate 10.1% (from 41.5 to 37.3 per 100,000) among Whites compared with 4.2% (from 66.2 to 63.4 per 100,000) among Blacks. Correction increased the White-Black disparity 6.1% (from 24.6 to 26.1 per 100,000). In 2008, NYC's White-Black premature heart disease death disparity was underestimated because of overreporting by hospitals serving larger proportions of Whites. Efforts to reduce overreporting may increase the observed disparity, potentially obscuring any programmatic or policy-driven advances.

  6. The immunological response of HIV-positive patients initiating HAART at the Komfo Anokye Teaching Hospital, Kumasi, Ghana.

    PubMed

    Annison, L; Dompreh, A; Adu-Sarkodie, Y

    2013-12-01

    The study sought to document the experience of immunological improvement among Ghanaian PLHIV on HAART comparing different categories of patients. Serology Unit, Komfo Anokye Teaching Hospital, Kumasi, Ghana. The study comprised a convenient sample of 303 treatment naïve HIV patients due to start HAART. Questionnaires were used to collect patient demographic and clinical data. Four CD4 counts were measured at six-monthly intervals to determine rates of CD4 change. These were pre-therapy, 1(st) post-therapy, 2(nd) post-therapy, and 3(rd) post-therapy counts. The rates of CD4 change among the different categories of patients were also compared. At baseline, women had higher CD4 count (mean of 77.4 cells/μl), and mean age of participants was 40 years. The CD4 count increased from a mean baseline of 70.2 cells/μl to 229.2, 270.0, and 297.6 cells/μl at 6, 12, and 18 months of treatment respectively (P < 0.0001 at each time point). There were no gender (P=0.46) and age (P=0.96) differences in treatment response. There was no difference (P=0.18) in treatment response comparing those with CD4 <250 cells/μl and those whose CD4 count was between 250 and 350 cells/μl at baseline although patients with baseline CD4 count <250 cells/μl showed larger increases after 12 months of treatment. Out of 282 patients with pre-therapy CD4 count ≤250 cells/μl, 241 (85.5%) and 41 (14.5%) were adherents and nonadherents respectively. Mean rate of increase was 15.2 and 8.4 cells/μl/month in adherent and non-adherent patients respectively (p=0.2). The study suggests that a sustained CD4 increase could be achieved in adherent patients commencing therapy with baseline CD4 count ≤250 cells/μl, and that these patients have greater ability for immunological recovery during 12 months of treatment The study, therefore, concludes that significant immunological improvement is possible among Ghanaian PLHIV on HAART as long as a high level of treatment adherence is observed.

  7. 29 CFR 452.107 - Observers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OF 1959 Election Procedures; Rights of Members § 452.107 Observers. (a) Under the provisions of... counting of the ballots. This right encompasses every phase and level of the counting and tallying process... his own observer. Observers do not have the right to count the ballots. (b) The right to have an...

  8. Feasibility study for epidemic prevention and control in a regional hospital.

    PubMed

    Chen, Yung-Liang; Yeh, Ming-Yang; Huang, Shau-Yen; Liu, Chi-Ming; Sun, Chi-Chen; Lu, Hsu-Feng; Chiu, Tsan-Hung; Hsia, Te-Chun; Chung, Jing-Gung

    2012-03-01

    Epidemic prevention policies in hospitals address issues such as, indoor air quality control, cleanliness of medical staff clothing and employee hand-washing procedures. Our hospital employed Bio-Kil to treat air-conditioning filters and nursing staff uniforms. We also assessed the efficacy of different detergents. Using Bio-Kil technology, the mean bacterial count in the air was reduced from 108.8 CFU/h/plate (n=420) to 68.6 CFU/h/plate (n=630). On the lower hems of the Bio-Kil-treated gowns, the mean bacterial count was 1,201 CFU/100 cm(2), markedly lower than the bacterial count of 7,753 CFU/100 cm(2), found on the parts of the gowns not treated with Bio-Kil (p=0.0401). On the cuffs of sleeves treated with Bio-Kil, the mean count was 1,165 CFU/100 cm(2), markedly lower than that of 2,131 CFU/100 cm(2), found on the cuffs not treated with Bio-Kil (p=0.0073). With regard to the mean bacterial eradication rates of antimicrobial solutions, Steridal Solution, 75% alcohol and Bio-Kil (3rd generation) were shown to be the most effective, with rates exceeding 80%. Hibiscrub with paper towels and Fresh Protect Skin were the second most effective. Bio-Kil (1st generation), tap water with paper towels, liquid hand soap with paper towels and ozone water were the least effective. One important observation was that hand-washing without the use of paper towels increased the bacterial count by as much as 84% . Bio-Kil is effective in reducing bacterial counts in the air, on nursing staff uniforms and is an effective detergent.

  9. Haematology and serum chemistry of Pyrenean chamois (Rupicapra pyrenaica) naturally infected with a border disease virus.

    PubMed

    Fernández-Sirera, L; Mentaberre, G; López-Olvera, J R; Cuenca, R; Lavín, S; Marco, I

    2011-06-01

    In 2005 and 2006 an outbreak of disease associated with border disease virus (BDV) infection caused high mortality in the Pyrenean chamois (Rupicapra pyrenaica) in the Catalan Pyrenees (NE Spain). The aim of this study was to determine values for different haematological and serum biochemical analytes in 32 free-ranging Pyrenean chamois affected by the disease and to compare them with those obtained from healthy chamois. In the affected chamois red blood cell counts, haemoglobin concentrations, packed cell volumes, mean corpuscular volumes and lymphocyte counts were all lower, while the neutrophil and platelet counts were higher. Glucose, lactate, triglycerides, creatinine, total protein concentrations and alkaline phosphatase activity were also lower, in contrast to the concentrations of total bilirubin, urea and aspartate aminotransferase activity, which were higher. Most of the observed changes could be associated with cachexia and inflammation in the affected chamois. Lymphopenia could be directly related to the BDV, which would lead to immunosuppression and explain the high rate of secondary infection observed in these animals. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Predictors of Clinical Progression in HIV-1-Infected Adults Initiating Combination Antiretroviral Therapy with Advanced Disease in the Asia-Pacific Region: Results from the TREAT Asia HIV Observational Database

    PubMed Central

    Byakwaga, H.; Petoumenos, K.; Ananworanich, J.; Zhang, F.; Boyd, M. A.; Sirisanthana, T.; Li, P. C. K.; Lee, C.; Mean, C. V.; Saphonn, V.; Omar, S. F. S.; Pujari, S.; Phanuphak, P.; Lim, P. L.; Kumarasamy, N.; Chen, Y. M. A.; Merati, T. P.; Sungkanuparph, S.; Ditangco, R.; Oka, S.; Tau, G.; Zhou, J.; Law, M. G.; Emery, S.

    2013-01-01

    The majority of HIV-infected patients in developing countries commences combination antiretroviral therapy (cART) with advanced disease. We examined predictors of disease progression in patients initiating cART with CD4 count ≤200 cells/mm3 in the TREAT Asia HIV Observational Database. The main outcome measure was progression to either an AIDS-defining illness or death occurring 6 months after initiation of cART. We used survival analysis methods. A total of 1255 patients contributed 2696 person years of follow-up; 73 were diagnosed with AIDS and 9 died. The rate of progression to the combined end point was 3.0 per 100 person years. The factors significantly associated with a higher risk of disease progression were Indian ethnicity, infection through intravenous drug use, lower CD4 count, and hemoglobin ≤130 g/dL at 6 months. In conclusion, measurements of CD4 count and hemoglobin at month 6 may be useful for early identification of disease progression in resource-limited settings. PMID:23422741

  11. Study of Rubber Composites with Positron Doppler Broadening Spectroscopy: Consideration of Counting Rate

    NASA Astrophysics Data System (ADS)

    Yang, Chun; Quarles, C. A.

    2007-10-01

    We have used positron Doppler Broadening Spectroscopy (DBS) to investigate the uniformity of rubber-carbon black composite samples. The amount of carbon black added to a rubber sample is characterized by phr, the number of grams of carbon black per hundred grams of rubber. Typical concentrations in rubber tires are 50 phr. It has been shown that the S parameter measured by DBS depends on the phr of the sample, so the variation in carbon black concentration can be easily measured to 0.5 phr. In doing the experiments we observed a dependence of the S parameter on small variation in the counting rate or deadtime. By carefully calibrating this deadtime correction we can significantly reduce the experimental run time and thus make faster determination of the uniformity of extended samples.

  12. Gastrointestinal health effects associated with the consumption of drinking water produced by point-of-use domestic reverse-osmosis filtration units.

    PubMed Central

    Payment, P; Franco, E; Richardson, L; Siemiatycki, J

    1991-01-01

    During a prospective epidemiological study of gastrointestinal health effects associated with the consumption of drinking water produced by reverse-osmosis domestic units, a correlation was demonstrated between the bacterial counts on R2A medium incubated at 35 degrees C and the reported gastrointestinal symptoms in families who used these units. A univariate correlation was found with bacterial counts on R2A medium at 20 degrees C but was confounded by the bacterial counts at 35 degrees C. Other variables, such as family size and amount of water consumed, were not independently explanatory of the rate of illness. These observations raise concerns for the possibility of increased disease associated with certain point-of-use treatment devices for domestic use when high levels of bacterial growth occur. PMID:2059052

  13. Single photon counting linear mode avalanche photodiode technologies

    NASA Astrophysics Data System (ADS)

    Williams, George M.; Huntington, Andrew S.

    2011-10-01

    The false count rate of a single-photon-sensitive photoreceiver consisting of a high-gain, low-excess-noise linear-mode InGaAs avalanche photodiode (APD) and a high-bandwidth transimpedance amplifier (TIA) is fit to a statistical model. The peak height distribution of the APD's multiplied dark current is approximated by the weighted sum of McIntyre distributions, each characterizing dark current generated at a different location within the APD's junction. The peak height distribution approximated in this way is convolved with a Gaussian distribution representing the input-referred noise of the TIA to generate the statistical distribution of the uncorrelated sum. The cumulative distribution function (CDF) representing count probability as a function of detection threshold is computed, and the CDF model fit to empirical false count data. It is found that only k=0 McIntyre distributions fit the empirically measured CDF at high detection threshold, and that false count rate drops faster than photon count rate as detection threshold is raised. Once fit to empirical false count data, the model predicts the improvement of the false count rate to be expected from reductions in TIA noise and APD dark current. Improvement by at least three orders of magnitude is thought feasible with further manufacturing development and a capacitive-feedback TIA (CTIA).

  14. Nova Lup 2016 during the X-ray decay phase

    NASA Astrophysics Data System (ADS)

    Orio, Marina; Beardmore, Andrew; Page, Kim; Osborne, Julian

    2017-09-01

    Nova Lup 2016 (ASASSN-16kt; see ATel #9538, #9539, #8550, #9554, #9587, #9594 and #9644) has been regularly monitored with Swift since the observations published in ATel #10632 that revealed a luminous supersoft X-ray source with a peak XRT count rate of 61.1(+-)0.1 cts/s on 2017/2/22.

  15. Can simple mobile phone applications provide reliable counts of respiratory rates in sick infants and children? An initial evaluation of three new applications.

    PubMed

    Black, James; Gerdtz, Marie; Nicholson, Pat; Crellin, Dianne; Browning, Laura; Simpson, Julie; Bell, Lauren; Santamaria, Nick

    2015-05-01

    Respiratory rate is an important sign that is commonly either not recorded or recorded incorrectly. Mobile phone ownership is increasing even in resource-poor settings. Phone applications may improve the accuracy and ease of counting of respiratory rates. The study assessed the reliability and initial users' impressions of four mobile phone respiratory timer approaches, compared to a 60-second count by the same participants. Three mobile applications (applying four different counting approaches plus a standard 60-second count) were created using the Java Mobile Edition and tested on Nokia C1-01 phones. Apart from the 60-second timer application, the others included a counter based on the time for ten breaths, and three based on the time interval between breaths ('Once-per-Breath', in which the user presses for each breath and the application calculates the rate after 10 or 20 breaths, or after 60s). Nursing and physiotherapy students used the applications to count respiratory rates in a set of brief video recordings of children with different respiratory illnesses. Limits of agreement (compared to the same participant's standard 60-second count), intra-class correlation coefficients and standard errors of measurement were calculated to compare the reliability of the four approaches, and a usability questionnaire was completed by the participants. There was considerable variation in the counts, with large components of the variation related to the participants and the videos, as well as the methods. None of the methods was entirely reliable, with no limits of agreement better than -10 to +9 breaths/min. Some of the methods were superior to the others, with ICCs from 0.24 to 0.92. By ICC the Once-per-Breath 60-second count and the Once-per-Breath 20-breath count were the most consistent, better even than the 60-second count by the participants. The 10-breath approaches performed least well. Users' initial impressions were positive, with little difference between the applications found. This study provides evidence that applications running on simple phones can be used to count respiratory rates in children. The Once-per-Breath methods are the most reliable, outperforming the 60-second count. For children with raised respiratory rates the 20-breath version of the Once-per-Breath method is faster, so it is a more suitable option where health workers are under time pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Optical levitation of a microdroplet containing a single quantum dot.

    PubMed

    Minowa, Yosuke; Kawai, Ryoichi; Ashida, Masaaki

    2015-03-15

    We demonstrate the optical levitation or trapping in helium gas of a single quantum dot (QD) within a liquid droplet. Bright single photon emission from the levitated QD in the droplet was observed for more than 200 s. The observed photon count rates are consistent with the value theoretically estimated from the two-photon-action cross section. This Letter presents the realization of an optically levitated solid-state quantum emitter.

  17. Carica papaya Leaves Juice Significantly Accelerates the Rate of Increase in Platelet Count among Patients with Dengue Fever and Dengue Haemorrhagic Fever

    PubMed Central

    Subenthiran, Soobitha; Choon, Tan Chwee; Cheong, Kee Chee; Thayan, Ravindran; Teck, Mok Boon; Muniandy, Prem Kumar; Afzan, Adlin; Abdullah, Noor Rain; Ismail, Zakiah

    2013-01-01

    The study was conducted to investigate the platelet increasing property of Carica papaya leaves juice (CPLJ) in patients with dengue fever (DF). An open labeled randomized controlled trial was carried out on 228 patients with DF and dengue haemorrhagic fever (DHF). Approximately half the patients received the juice, for 3 consecutive days while the others remained as controls and received the standard management. Their full blood count was monitored 8 hours for 48 hours. Gene expression studies were conducted on the ALOX 12 and PTAFR genes. The mean increase in platelet counts were compared in both groups using repeated measure ANCOVA. There was a significant increase in mean platelet count observed in the intervention group (P < 0.001) but not in the control group 40 hours since the first dose of CPLJ. Comparison of mean platelet count between intervention and control group showed that mean platelet count in intervention group was significantly higher than control group after 40 and 48 hours of admission (P < 0.01). The ALOX 12 (FC  =  15.00) and PTAFR (FC  =  13.42) genes were highly expressed among those on the juice. It was concluded that CPLJ does significantly increase the platelet count in patients with DF and DHF. PMID:23662145

  18. A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cammin, Jochen, E-mail: jcammin1@jhmi.edu, E-mail: ktaguchi@jhmi.edu; Taguchi, Katsuyuki, E-mail: jcammin1@jhmi.edu, E-mail: ktaguchi@jhmi.edu; Xu, Jennifer

    Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra andmore » count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.« less

  19. A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

    PubMed Central

    Cammin, Jochen; Xu, Jennifer; Barber, William C.; Iwanczyk, Jan S.; Hartsough, Neal E.; Taguchi, Katsuyuki

    2014-01-01

    Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi , “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COVW), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COVW's less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COVW was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE. PMID:24694136

  20. Analysis of Sample Size, Counting Time, and Plot Size from an Avian Point Count Survey on Hoosier National Forest, Indiana

    Treesearch

    Frank R. Thompson; Monica J. Schwalbach

    1995-01-01

    We report results of a point count survey of breeding birds on Hoosier National Forest in Indiana. We determined sample size requirements to detect differences in means and the effects of count duration and plot size on individual detection rates. Sample size requirements ranged from 100 to >1000 points with Type I and II error rates of <0.1 and 0.2. Sample...

  1. Predicting U.S. tuberculosis case counts through 2020.

    PubMed

    Woodruff, Rachel S Y E L K; Winston, Carla A; Miramontes, Roque

    2013-01-01

    In 2010, foreign-born persons accounted for 60% of all tuberculosis (TB) cases in the United States. Understanding which national groups make up the highest proportion of TB cases will assist TB control programs in concentrating limited resources where they can provide the greatest impact on preventing transmission of TB disease. The objective of our study was to predict through 2020 the numbers of U.S. TB cases among U.S.-born, foreign-born and foreign-born persons from selected countries of birth. TB case counts reported through the National Tuberculosis Surveillance System from 2000-2010 were log-transformed, and linear regression was performed to calculate predicted annual case counts and 95% prediction intervals for 2011-2020. Data were analyzed in 2011 before 2011 case counts were known. Decreases were predicted between 2010 observed and 2020 predicted counts for total TB cases (11,182 to 8,117 [95% prediction interval 7,262-9,073]) as well as TB cases among foreign-born persons from Mexico (1,541 to 1,420 [1,066-1,892]), the Philippines (740 to 724 [569-922]), India (578 to 553 [455-672]), Vietnam (532 to 429 [367-502]) and China (364 to 328 [249-433]). TB cases among persons who are U.S.-born and foreign-born were predicted to decline 47% (4,393 to 2,338 [2,113-2,586]) and 6% (6,720 to 6,343 [5,382-7,476]), respectively. Assuming rates of declines observed from 2000-2010 continue until 2020, a widening gap between the numbers of U.S.-born and foreign-born TB cases was predicted. TB case count predictions will help TB control programs identify needs for cultural competency, such as languages and interpreters needed for translating materials or engaging in appropriate community outreach.

  2. A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.

    PubMed

    Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi

    2010-04-01

    The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.

  3. Observation of the thunderstorm-related ground cosmic ray flux variations by ARGO-YBJ

    NASA Astrophysics Data System (ADS)

    Bartoli, B.; Bernardini, P.; Bi, X. J.; Cao, Z.; Catalanotti, S.; Chen, S. Z.; Chen, T. L.; Cui, S. W.; Dai, B. Z.; D'Amone, A.; Danzengluobu; De Mitri, I.; D'Ettorre Piazzoli, B.; Di Girolamo, T.; Di Sciascio, G.; Feng, C. F.; Feng, Zhaoyang; Feng, Zhenyong; Gao, W.; Gou, Q. B.; Guo, Y. Q.; He, H. H.; Hu, Haibing; Hu, Hongbo; Iacovacci, M.; Iuppa, R.; Jia, H. Y.; Labaciren; Li, H. J.; Liu, C.; Liu, J.; Liu, M. Y.; Lu, H.; Ma, L. L.; Ma, X. H.; Mancarella, G.; Mari, S. M.; Marsella, G.; Mastroianni, S.; Montini, P.; Ning, C. C.; Perrone, L.; Pistilli, P.; Salvini, P.; Santonico, R.; Shen, P. R.; Sheng, X. D.; Shi, F.; Surdo, A.; Tan, Y. H.; Vallania, P.; Vernetto, S.; Vigorito, C.; Wang, H.; Wu, C. Y.; Wu, H. R.; Xue, L.; Yang, Q. Y.; Yang, X. C.; Yao, Z. G.; Yuan, A. F.; Zha, M.; Zhang, H. M.; Zhang, L.; Zhang, X. Y.; Zhang, Y.; Zhao, J.; Zhaxiciren; Zhaxisangzhu; Zhou, X. X.; Zhu, F. R.; Zhu, Q. Q.; D'Alessandro, F.; ARGO-YBJ Collaboration

    2018-02-01

    A correlation between the secondary cosmic ray flux and the near-earth electric field intensity, measured during thunderstorms, has been found by analyzing the data of the ARGO-YBJ experiment, a full coverage air shower array located at the Yangbajing Cosmic Ray Laboratory (4300 m a. s. l., Tibet, China). The counting rates of showers with different particle multiplicities (m =1 , 2, 3, and ≥4 ) have been found to be strongly dependent upon the intensity and polarity of the electric field measured during the course of 15 thunderstorms. In negative electric fields (i.e., accelerating negative charges downwards), the counting rates increase with increasing electric field strength. In positive fields, the rates decrease with field intensity until a certain value of the field EFmin (whose value depends on the event multiplicity), above which the rates begin increasing. By using Monte Carlo simulations, we found that this peculiar behavior can be well described by the presence of an electric field in a layer of thickness of a few hundred meters in the atmosphere above the detector, which accelerates/decelerates the secondary shower particles of opposite charge, modifying the number of particles with energy exceeding the detector threshold. These results, for the first time to our knowledge, give a consistent explanation for the origin of the variation of the electron/positron flux observed for decades by high altitude cosmic ray detectors during thunderstorms.

  4. Estimating the Effective System Dead Time Parameter for Correlated Neutron Counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Croft, Stephen; Cleveland, Steve; Favalli, Andrea

    We present that neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correctingmore » these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. In addition, this latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.« less

  5. Estimating the Effective System Dead Time Parameter for Correlated Neutron Counting

    DOE PAGES

    Croft, Stephen; Cleveland, Steve; Favalli, Andrea; ...

    2017-04-29

    We present that neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correctingmore » these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. In addition, this latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.« less

  6. Estimating the effective system dead time parameter for correlated neutron counting

    NASA Astrophysics Data System (ADS)

    Croft, Stephen; Cleveland, Steve; Favalli, Andrea; McElroy, Robert D.; Simone, Angela T.

    2017-11-01

    Neutron time correlation analysis is one of the main technical nuclear safeguards techniques used to verify declarations of, or to independently assay, special nuclear materials. Quantitative information is generally extracted from the neutron-event pulse train, collected from moderated assemblies of 3He proportional counters, in the form of correlated count rates that are derived from event-triggered coincidence gates. These count rates, most commonly referred to as singles, doubles and triples rates etc., when extracted using shift-register autocorrelation logic, are related to the reduced factorial moments of the time correlated clusters of neutrons emerging from the measurement items. Correcting these various rates for dead time losses has received considerable attention recently. The dead time losses for the higher moments in particular, and especially for large mass (high rate and highly multiplying) items, can be significant. Consequently, even in thoughtfully designed systems, accurate dead time treatments are needed if biased mass determinations are to be avoided. In support of this effort, in this paper we discuss a new approach to experimentally estimate the effective system dead time of neutron coincidence counting systems. It involves counting a random neutron source (e.g. AmLi is a good approximation to a source without correlated emission) and relating the second and higher moments of the neutron number distribution recorded in random triggered interrogation coincidence gates to the effective value of dead time parameter. We develop the theoretical basis of the method and apply it to the Oak Ridge Large Volume Active Well Coincidence Counter using sealed AmLi radionuclide neutron sources and standard multiplicity shift register electronics. The method is simple to apply compared to the predominant present approach which involves using a set of 252Cf sources of wide emission rate, it gives excellent precision in a conveniently short time, and it yields consistent results as a function of the order of the moment used to extract the dead time parameter. This latter observation is reassuring in that it suggests the assumptions underpinning the theoretical analysis are fit for practical application purposes. However, we found that the effective dead time parameter obtained is not constant, as might be expected for a parameter that in the dead time model is characteristic of the detector system, but rather, varies systematically with gate width.

  7. Cancer, immunodeficiency and antiretroviral treatment: results from the Australian HIV Observational Database (AHOD).

    PubMed

    Petoumenos, K; van Leuwen, M T; Vajdic, C M; Woolley, I; Chuah, J; Templeton, D J; Grulich, A E; Law, M G

    2013-02-01

    The objective of the study was to conduct a within-cohort assessment of risk factors for incident AIDS-defining cancers (ADCs) and non-ADCs (NADCs) within the Australian HIV Observational Database (AHOD). A total of 2181 AHOD registrants were linked to the National AIDS Registry/National HIV Database (NAR/NHD) and the Australian Cancer Registry to identify those with a notified cancer diagnosis. Included in the current analyses were cancers diagnosed after HIV infection. Risk factors for cancers were also assessed using logistic regression methods. One hundred and thirty-nine cancer cases were diagnosed after HIV infection among 129 patients. More than half the diagnoses (n = 68; 60%) were ADCs, of which 69% were Kaposi's sarcoma and 31% non-Hodgkin's lymphoma. Among the NADCs, the most common cancers were melanoma (n = 10), lung cancer (n = 6), Hodgkin's lymphoma (n = 5) and anal cancer (n = 5). Over a total of 21021 person-years (PY) of follow-up since HIV diagnosis, the overall crude cancer incidence rate for any cancer was 5.09/1000 PY. The overall rate of cancers decreased from 15.9/1000 PY [95% confidence interval (CI) 9.25-25.40/1000 PY] for CD4 counts < 100 cells/μL to 2.4/1000 PY (95% CI 1.62-3.39/1000 PY) for CD4 counts > 350 cells/μL. Lower CD4 cell count and prior AIDS diagnoses were significant predictors for both ADCs and NADCs. ADCs remain the predominant cancers in this population, although NADC rates have increased in the more recent time period. Immune deficiency is a risk factor for both ADCs and NADCs. © 2012 British HIV Association.

  8. Anomalous effects of radioactive decay rates and capacitance values measured inside a modified Faraday cage: Correlations with space weather

    NASA Astrophysics Data System (ADS)

    Scholkmann, F.; Milián-Sánchez, V.; Mocholí-Salcedo, A.; Milián, C.; Kolombet, V. A.; Verdú, G.

    2017-03-01

    Recently we reported (Milián-Sánchez V. et al., Nucl. Instrum. Methods A, 828 (2016) 210) our experimental results involving 226Ra decay rate and capacitance measurements inside a modified Faraday cage. Our measurements exhibited anomalous effects of unknown origin. In this letter we report new results regarding our investigation into the origins of the observed effects. We report preliminary findings of a correlation analysis between the radioactive decay rates and capacitance time series and space weather related variables (geomagnetic field disturbances and cosmic-ray neutron counts). A significant correlation was observed for specific data sets. The results are presented and possible implications for future work discussed.

  9. Evidence Accumulation and Change Rate Inference in Dynamic Environments.

    PubMed

    Radillo, Adrian E; Veliz-Cuba, Alan; Josić, Krešimir; Kilpatrick, Zachary P

    2017-06-01

    In a constantly changing world, animals must account for environmental volatility when making decisions. To appropriately discount older, irrelevant information, they need to learn the rate at which the environment changes. We develop an ideal observer model capable of inferring the present state of the environment along with its rate of change. Key to this computation is an update of the posterior probability of all possible change point counts. This computation can be challenging, as the number of possibilities grows rapidly with time. However, we show how the computations can be simplified in the continuum limit by a moment closure approximation. The resulting low-dimensional system can be used to infer the environmental state and change rate with accuracy comparable to the ideal observer. The approximate computations can be performed by a neural network model via a rate-correlation-based plasticity rule. We thus show how optimal observers accumulate evidence in changing environments and map this computation to reduced models that perform inference using plausible neural mechanisms.

  10. Transforming geographic scale: a comparison of combined population and areal weighting to other interpolation methods.

    PubMed

    Hallisey, Elaine; Tai, Eric; Berens, Andrew; Wilt, Grete; Peipins, Lucy; Lewis, Brian; Graham, Shannon; Flanagan, Barry; Lunsford, Natasha Buchanan

    2017-08-07

    Transforming spatial data from one scale to another is a challenge in geographic analysis. As part of a larger, primary study to determine a possible association between travel barriers to pediatric cancer facilities and adolescent cancer mortality across the United States, we examined methods to estimate mortality within zones at varying distances from these facilities: (1) geographic centroid assignment, (2) population-weighted centroid assignment, (3) simple areal weighting, (4) combined population and areal weighting, and (5) geostatistical areal interpolation. For the primary study, we used county mortality counts from the National Center for Health Statistics (NCHS) and population data by census tract for the United States to estimate zone mortality. In this paper, to evaluate the five mortality estimation methods, we employed address-level mortality data from the state of Georgia in conjunction with census data. Our objective here is to identify the simplest method that returns accurate mortality estimates. The distribution of Georgia county adolescent cancer mortality counts mirrors the Poisson distribution of the NCHS counts for the U.S. Likewise, zone value patterns, along with the error measures of hierarchy and fit, are similar for the state and the nation. Therefore, Georgia data are suitable for methods testing. The mean absolute value arithmetic differences between the observed counts for Georgia and the five methods were 5.50, 5.00, 4.17, 2.74, and 3.43, respectively. Comparing the methods through paired t-tests of absolute value arithmetic differences showed no statistical difference among the methods. However, we found a strong positive correlation (r = 0.63) between estimated Georgia mortality rates and combined weighting rates at zone level. Most importantly, Bland-Altman plots indicated acceptable agreement between paired arithmetic differences of Georgia rates and combined population and areal weighting rates. This research contributes to the literature on areal interpolation, demonstrating that combined population and areal weighting, compared to other tested methods, returns the most accurate estimates of mortality in transforming small counts by county to aggregated counts for large, non-standard study zones. This conceptually simple cartographic method should be of interest to public health practitioners and researchers limited to analysis of data for relatively large enumeration units.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iyengar, Anagha; Beach, Matthew; Newby, Robert J.

    Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reductionmore » in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.« less

  12. Hematological changes in nephritis in poultry induced by diets high in protein, high in calcium, containing urea, or deficient in vitamin A.

    PubMed

    Chandra, M; Singh, B; Singh, N; Ahuja, S P

    1984-04-01

    Nephritis was induced in 300, 18-day-old male Arbor Acre broiler chicks by feeding diets high (42.28%) in protein, high (3.27%) in calcium, containing urea (5%), or deficient in vitamin A. Various hematological parameters were studied at weekly intervals. Normocytic-normochromic anemia, characterized by a decrease in total erythrocyte counts, hemoglobin, packed cell volume, and an increase in erythrocyte sedimentation rate, was evident in the birds kept on diets high in protein, high in calcium, or deficient in vitamin A. Increased total erythrocytes, hemoglobin packed cell volume, and erythrocyte sedimentation rate was observed in birds fed urea. Differential leucocyte counts revealed lymphopenia, heterophilia and monocytosis in birds kept on diets high in protein, containing urea, or deficient in vitamin A. However, lymphocytosis, heteropenia , and monocytosis were recorded in birds fed the high calcium diet.

  13. Gallium-67 scintigraphy, bronchoalveolar lavage, and pathologic changes in patients with pulmonary sarcoidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abe, S.; Munakata, M.; Nishimura, M.

    1984-05-01

    The intensity of gallium-67 scintiscans, lymphocyte counts in bronchoalveolar lavage fluid, and pathologic changes were studied in 26 patients with untreated pulmonary sarcoidosis. Noncaseating granulomas were recognized with significantly greater frequency in stage 2 (80 percent; 8/10 cases) than in stage 1 (43 percent; 6/14 cases). Alveolitis showed little relation to the roentgenographic stage. There was a strong correlation between the intensity of gallium uptake in pulmonary parenchyma and the detection rate of granuloma; however, the detection rate of alveolitis was not statistically different from the intensity of gallium uptake. A highly significant correlation was revealed between the lymphocyte countsmore » in bronchoalveolar lavage fluid and the intensity of alveolitis. These observations suggest that the gallium uptake reflects mainly the presence of granuloma, and the lymphocyte count in bronchoalveolar lavage fluid reflects the intensity of alveolitis in patients with pulmonary sarcoidosis.« less

  14. Analysis of the Complex Forbush Decreases of June 2015

    NASA Astrophysics Data System (ADS)

    Lara, A.; Santiago, A.

    2016-12-01

    We investigated the sudden increase of the counting rates observed by muon telescopes during the main phase of the June 20, 2015 Forbush decrease. We analyzed the probability that this peak was caused by a shock reacceleration of solar energetic particles accelerated by the solar flare occurred on June 22, 2015. To study this event, we used ground level cosmic ray detectors, GOES proton intensities, observations of the geomagnetic activity index (Dst) and interplanetary magnetic field data observed by ACE and WIND spacecraft available from the OMNI database.

  15. Effect of metronome rates on the quality of bag-mask ventilation during metronome-guided 30:2 cardiopulmonary resuscitation: A randomized simulation study.

    PubMed

    Na, Ji Ung; Han, Sang Kuk; Choi, Pil Cho; Shin, Dong Hyuk

    2017-01-01

    Metronome guidance is a feasible and effective feedback technique to improve the quality of cardiopulmonary resuscitation (CPR). The rate of the metronome should be set between 100 to 120 ticks/minute and the speed of ventilation may have crucial effect on the quality of ventilation. We compared three different metronome rates (100, 110, 120 ticks/minute) to investigate its effect on the quality of ventilation during metronome-guided 30:2 CPR. This is a prospective, randomized, crossover observational study using a RespiTrainer○ r . To simulate 30 chest compressions, one investigator counted from 1 to 30 in cadence with the metronome rate (1 count for every 1 tick), and the participant performed 2 consecutive ventilations immediately following the counting of 30. Thirty physicians performed 5 sets of 2 consecutive (total 10) bag-mask ventilations for each metronome rate. Participants were instructed to squeeze the bag over 2 ticks (1.0 to 1.2 seconds depending on the rate of metronome) and deflate the bag over 2 ticks. The sequence of three different metronome rates was randomized. Mean tidal volume significantly decreased as the metronome rate was increased from 110 ticks/minute to 120 ticks/minute (343±84 mL vs. 294±90 mL, P =0.004). Peak airway pressure significantly increased as metronome rate increased from 100 ticks/minute to 110 ticks/minute (18.7 vs. 21.6 mmHg, P =0.006). In metronome-guided 30:2 CPR, a higher metronome rate may adversely affect the quality of bag-mask ventilations. In cases of cardiac arrest where adequate ventilation support is necessary, 100 ticks/minute may be better than 110 or 120 ticks/minute to deliver adequate tidal volume during audio tone guided 30:2 CPR.

  16. Effect of metronome rates on the quality of bag-mask ventilation during metronome-guided 30:2 cardiopulmonary resuscitation: A randomized simulation study

    PubMed Central

    Na, Ji Ung; Han, Sang Kuk; Choi, Pil Cho; Shin, Dong Hyuk

    2017-01-01

    BACKGROUND: Metronome guidance is a feasible and effective feedback technique to improve the quality of cardiopulmonary resuscitation (CPR). The rate of the metronome should be set between 100 to 120 ticks/minute and the speed of ventilation may have crucial effect on the quality of ventilation. We compared three different metronome rates (100, 110, 120 ticks/minute) to investigate its effect on the quality of ventilation during metronome-guided 30:2 CPR. METHODS: This is a prospective, randomized, crossover observational study using a RespiTrainer○r. To simulate 30 chest compressions, one investigator counted from 1 to 30 in cadence with the metronome rate (1 count for every 1 tick), and the participant performed 2 consecutive ventilations immediately following the counting of 30. Thirty physicians performed 5 sets of 2 consecutive (total 10) bag-mask ventilations for each metronome rate. Participants were instructed to squeeze the bag over 2 ticks (1.0 to 1.2 seconds depending on the rate of metronome) and deflate the bag over 2 ticks. The sequence of three different metronome rates was randomized. RESULTS: Mean tidal volume significantly decreased as the metronome rate was increased from 110 ticks/minute to 120 ticks/minute (343±84 mL vs. 294±90 mL, P=0.004). Peak airway pressure significantly increased as metronome rate increased from 100 ticks/minute to 110 ticks/minute (18.7 vs. 21.6 mmHg, P=0.006). CONCLUSION: In metronome-guided 30:2 CPR, a higher metronome rate may adversely affect the quality of bag-mask ventilations. In cases of cardiac arrest where adequate ventilation support is necessary, 100 ticks/minute may be better than 110 or 120 ticks/minute to deliver adequate tidal volume during audio tone guided 30:2 CPR. PMID:28458759

  17. Photographic techniques for characterizing streambed particle sizes

    USGS Publications Warehouse

    Whitman, Matthew S.; Moran, Edward H.; Ourso, Robert T.

    2003-01-01

    We developed photographic techniques to characterize coarse (>2-mm) and fine (≤2-mm) streambed particle sizes in 12 streams in Anchorage, Alaska. Results were compared with current sampling techniques to assess which provided greater sampling efficiency and accuracy. The streams sampled were wadeable and contained gravel—cobble streambeds. Gradients ranged from about 5% at the upstream sites to about 0.25% at the downstream sites. Mean particle sizes and size-frequency distributions resulting from digitized photographs differed significantly from those resulting from Wolman pebble counts for five sites in the analysis. Wolman counts were biased toward selecting larger particles. Photographic analysis also yielded a greater number of measured particles (mean = 989) than did the Wolman counts (mean = 328). Stream embeddedness ratings assigned from field and photographic observations were significantly different at 5 of the 12 sites, although both types of ratings showed a positive relationship with digitized surface fines. Visual estimates of embeddedness and digitized surface fines may both be useful indicators of benthic conditions, but digitizing surface fines produces quantitative rather than qualitative data. Benefits of the photographic techniques include reduced field time, minimal streambed disturbance, convenience of postfield processing, easy sample archiving, and improved accuracy and replication potential.

  18. Progress towards barium daughter tagging in Xe136 decay using single molecule fluorescence imaging

    NASA Astrophysics Data System (ADS)

    McDonald, Austin; NEXT Collaboration

    2017-09-01

    The existence of Majorana fermions is of great interest as it may be related to the asymmetry between matter and anti-matter particles in the universe. However, the search for them has proven to be a difficult one. Neutrino-less Double Beta decay (NLDB) offers a possible opportunity for direct observation of a Majorana Fermion. The rate for NLDB decay may be as low as 1 count /ton /year if the mass ordering is inverted. Current detector technologies have background rates between 4 to 300 count /ton /year /ROI at the 100kg scale which is much larger than the universal goal of 0.1 count /ton /year /ROI desired for ton-scale detectors. The premise of my research is to develop new detector technologies that will allow for a background-free experiment. My current work is to develop a sensor that will tag the daughter ion Ba++ from the Xe136 decay. The development of a sensor that is sensitive to single barium ion detection based on the single molecule fluorescence imaging technique is the major focus of this work. If successful, this could provide a path to a background-free experiment.

  19. Progress towards barium daughter tagging in Xe136 decay using single molecule fluorescence imaging

    NASA Astrophysics Data System (ADS)

    McDonald, Austin; Jones, Ben; Benson, Jordan; Nygren, David; NEXT Collaboration

    2017-01-01

    The existence of Majorana Fermions has been predicted, and is of great interest as it may be related to the asymmetry between matter and anti-matter particles in the universe. However, the search for them has proven to be a difficult one. Neutrino-less Double Beta decay (NLDB) offers a possible opportunity for direct observation of a Majorana Fermion. The rate for NLDB decay may be as low as 1 count / ton / year . Current detector technologies have background rates between 4 to 300 count / ton / year / ROI which is much larger than the universal goal of 0 . 1 count / ton / year / ROI desired for ton-scale detectors. The premise of my research is to develop new detector technologies that will allow for a background-free experiment. My current work is to develop a sensor that will tag the daughter ion Ba++ from the Xe136 decay. The development of a sensor that is sensitive to single barium ion detection based on the single molecule fluorescence imaging technique is the major focus of this work. If successful, this could provide a path to a background-free experiment.

  20. Oligodendroglial response to ionizing radiation: Dose and dose-rate response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levy, R.P.

    1991-01-01

    An in vitro system using neuroglia from neonatal rat brain was developed to examining the morphologic, immunocytochemical and biochemical response of oligodendroglia to ionizing radiation. Following acute [gamma]-radiation at day-in-culture (DIC) 8, oligodendrocyte counts at DIC 14 were 55% to 65% of control values after 2 Gy, and 29% to 36% after 5 Gy. Counts increased to near-normal levels at DIC 21 in the 2 Gy group and to 75% of normal in the 5 Gy group. Myelin basic protein levels (MBP) at DIC 14 were 60% of control values after 2 Gy, and 40% after 5 Gy. At DICmore » 21, MBP after 2 Gy was 45% greater than that observed at DIC 14, but MBP, as a fraction of age-matched control values, dropped from 60% to 50%. Following 5 Gy, absolute MBP changed little between DIC 14 and DIC 21, but decreased from 40% to 25% of control cultures. It was concluded that oligodendrocytes in irradiated cultures had significantly lower functional capacity than did unirradiated controls. The response to split-dose irradiation indicated that nearly all sublethal damage in the oligodendrocyte population (and its precursors) was repaired within 3 h to 4 h. At DIC 14, the group irradiated in a single fraction had significantly lower oligodendrocyte counts than any group given split doses; all irradiated cultures had marked depression of MBP synthesis, but to significant differences referable to time interval between doses. At DIC 21, cultures irradiated at intervals of 0 h to 2 h had similar oligodendrocyte counts to one another, but these counts were significantly lower than in cultures irradiated at intervals of 4 h to 6 h; MBP levels remained depressed at DIC 21 for all irradiated cultures. The oligodendrocyte response to dose rate (0.03 to 1.97 Gy/min) was evaluated at DIC 14 and DIC 21. Exposure at 0.03 Gy/min suppressed oligodendrocyte counts at DIC 21 less than did higher dose rates in 5-Gy irradiated cultures.« less

  1. Single Photon Counting Detectors for Low Light Level Imaging Applications

    NASA Astrophysics Data System (ADS)

    Kolb, Kimberly

    2015-10-01

    This dissertation presents the current state-of-the-art of semiconductor-based photon counting detector technologies. HgCdTe linear-mode avalanche photodiodes (LM-APDs), silicon Geiger-mode avalanche photodiodes (GM-APDs), and electron-multiplying CCDs (EMCCDs) are compared via their present and future performance in various astronomy applications. LM-APDs are studied in theory, based on work done at the University of Hawaii. EMCCDs are studied in theory and experimentally, with a device at NASA's Jet Propulsion Lab. The emphasis of the research is on GM-APD imaging arrays, developed at MIT Lincoln Laboratory and tested at the RIT Center for Detectors. The GM-APD research includes a theoretical analysis of SNR and various performance metrics, including dark count rate, afterpulsing, photon detection efficiency, and intrapixel sensitivity. The effects of radiation damage on the GM-APD were also characterized by introducing a cumulative dose of 50 krad(Si) via 60 MeV protons. Extensive development of Monte Carlo simulations and practical observation simulations was completed, including simulated astronomical imaging and adaptive optics wavefront sensing. Based on theoretical models and experimental testing, both the current state-of-the-art performance and projected future performance of each detector are compared for various applications. LM-APD performance is currently not competitive with other photon counting technologies, and are left out of the application-based comparisons. In the current state-of-the-art, EMCCDs in photon counting mode out-perform GM-APDs for long exposure scenarios, though GM-APDs are better for short exposure scenarios (fast readout) due to clock-induced-charge (CIC) in EMCCDs. In the long term, small improvements in GM-APD dark current will make them superior in both long and short exposure scenarios for extremely low flux. The efficiency of GM-APDs will likely always be less than EMCCDs, however, which is particularly disadvantageous for moderate to high flux rates where dark noise and CIC are insignificant noise sources. Research into decreasing the dark count rate of GM-APDs will lead to development of imaging arrays that are competitive for low light level imaging and spectroscopy applications in the near future.

  2. Extending pure luminosity evolution models into the mid-infrared, far-infrared and submillimetre

    NASA Astrophysics Data System (ADS)

    Hill, Michael D.; Shanks, Tom

    2011-07-01

    Simple pure luminosity evolution (PLE) models, in which galaxies brighten at high redshift due to increased star formation rates (SFRs), are known to provide a good fit to the colours and number counts of galaxies throughout the optical and near-infrared. We show that optically defined PLE models, where dust reradiates absorbed optical light into infrared spectra composed of local galaxy templates, fit galaxy counts and colours out to 8 μm and to at least z≈ 2.5. At 24-70 μm, the model is able to reproduce the observed source counts with reasonable success if 16 per cent of spiral galaxies show an excess in mid-IR flux due to a warmer dust component and a higher SFR, in line with observations of local starburst galaxies. There remains an underprediction of the number of faint-flux, high-z sources at 24 μm, so we explore how the evolution may be altered to correct this. At 160 μm and longer wavelengths, the model fails, with our model of normal galaxies accounting for only a few percent of sources in these bands. However, we show that a PLE model of obscured AGN, which we have previously shown to give a good fit to observations at 850 μm, also provides a reasonable fit to the Herschel/BLAST number counts and redshift distributions at 250-500 μm. In the context of a ΛCDM cosmology, an AGN contribution at 250-870 μm would remove the need to invoke a top-heavy IMF for high-redshift starburst galaxies.

  3. THE USE OF QUENCHING IN A LIQUID SCINTILLATION COUNTER FOR QUANTITATIVE ANALYSIS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Foster, G.V.

    1963-01-01

    Quenching was used to quantitatively determine the amonnt of quenching agent present. A sealed promethium147 source was prepared to be used for the count rate determinations. Two methods to determine the amount of quenching agent present in a sample were developed. One method related the count rate of a sample containing a quenching agent to the amount of quenching agent present. Calibration curves were plotted using both color and chemical quenchers. The quenching agents used were: F.D.C. Orange No. 2, F.D.C. Yellow No. 3, F.D.C. Yellow No. 4, Scarlet Red, acetone, benzaldehyde, and carbon tetrachloride. the color quenchers gave amore » linear-relationship, while the chemical quenchers gave a non-linear relationship. Quantities of the color quenchers between about 0.008 mg and 0.100 mg can be determined with an error less than 5%. The calibration curves were found to be usable over a long period of time. The other method related the change in the ratio of the count rates in two voltage windows to the amount of quenching agent present. The quenchers mentioned above were used. Calibration curves were plotted for both the color and chemical quenchers. The relationships of ratio versus amount of quencher were non-linear in each case. It was shown that the reproducibility of the count rate and the ratio was independent of the amount of quencher present but was dependent on the count rate. At count rates above 10,000 counts per minute the reproducibility was better than 1%. (TCO)« less

  4. The Hawaii SCUBA-2 Lensing Cluster Survey: Number Counts and Submillimeter Flux Ratios

    NASA Astrophysics Data System (ADS)

    Hsu, Li-Yen; Cowie, Lennox L.; Chen, Chian-Chou; Barger, Amy J.; Wang, Wei-Hao

    2016-09-01

    We present deep number counts at 450 and 850 μm using the SCUBA-2 camera on the James Clerk Maxwell Telescope. We combine data for six lensing cluster fields and three blank fields to measure the counts over a wide flux range at each wavelength. Thanks to the lensing magnification, our measurements extend to fluxes fainter than 1 mJy and 0.2 mJy at 450 μm and 850 μm, respectively. Our combined data highly constrain the faint end of the number counts. Integrating our counts shows that the majority of the extragalactic background light (EBL) at each wavelength is contributed by faint sources with L IR < 1012 L ⊙, corresponding to luminous infrared galaxies (LIRGs) or normal galaxies. By comparing our result with the 500 μm stacking of K-selected sources from the literature, we conclude that the K-selected LIRGs and normal galaxies still cannot fully account for the EBL that originates from sources with L IR < 1012 L ⊙. This suggests that many faint submillimeter galaxies may not be included in the UV star formation history. We also explore the submillimeter flux ratio between the two bands for our 450 μm and 850 μm selected sources. At 850 μm, we find a clear relation between the flux ratio and the observed flux. This relation can be explained by a redshift evolution, where galaxies at higher redshifts have higher luminosities and star formation rates. In contrast, at 450 μm, we do not see a clear relation between the flux ratio and the observed flux.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madanian, H.; Cravens, T. E.; Burch, J.

    The plasma environment near comet 67P/Churyumov–Gerasimenko (67P/CG) is dynamically affected by various factors, including the incident solar wind and outgassing from the nucleus. The Rosetta spacecraft MAGnetometer (MAG) instrument observations near perihelion showed crossing events into a magnetic field-free region at about 170 km from the nucleus in 2015 July at 1.26 au from the Sun. At each crossing, the magnitude of the magnetic field dropped by more than 20 nT to near zero. We compared the Ion and Electron Sensor (IES) electron differential flux energy spectrum inside and outside the crossing boundaries. The IES observations show a modest butmore » consistent drop in electron flux for energies between 40 eV and a few hundred eV at each cavity crossing event. This drop in the electron spectra might be due to the absence or attenuation of solar wind electrons inside the observed diamagnetic regions, which might or might not be a diamagnetic cavity. There is no apparent simple linear correlation between the electron count rate measured by the IES at different energies and the magnitude of the magnetic field, however; at all energies, the highest electron count rates are recorded at the highest magnetic field magnitudes. From model-data comparisons it seems that inside diamagnetic regions, pure coma photoelectrons are not sufficient to explain the observations and that a trapping mechanism and/or infused solar wind electrons are necessary to explain the observed electron fluxes.« less

  6. Statistical inference of static analysis rules

    NASA Technical Reports Server (NTRS)

    Engler, Dawson Richards (Inventor)

    2009-01-01

    Various apparatus and methods are disclosed for identifying errors in program code. Respective numbers of observances of at least one correctness rule by different code instances that relate to the at least one correctness rule are counted in the program code. Each code instance has an associated counted number of observances of the correctness rule by the code instance. Also counted are respective numbers of violations of the correctness rule by different code instances that relate to the correctness rule. Each code instance has an associated counted number of violations of the correctness rule by the code instance. A respective likelihood of the validity is determined for each code instance as a function of the counted number of observances and counted number of violations. The likelihood of validity indicates a relative likelihood that a related code instance is required to observe the correctness rule. The violations may be output in order of the likelihood of validity of a violated correctness rule.

  7. Crater Age and Hydrogen Content in Lunar Regolith from LEND Neutron Data

    NASA Astrophysics Data System (ADS)

    Sanin, Anton; Starr, Richard; Litvak, Maxim; Petro, Noah; Mitrofanov, Igor

    2017-04-01

    We are presenting an analysis of Lunar Exploration Neutron Detector (LEND) epithermal neutron count rates for a large set of mid-latitude craters. Epithermal neutron count rates for crater interiors measured by the LEND Sensor for Epithermal Neutrons (SETN) were compared to crater exteriors for 322 craters. An increase in relative count rate at about 9-sigma confidence level was found, consistent with a lower hydrogen content. A smaller subset of 31 craters, all located near three Copernican era craters, Jackson, Tycho, and Necho, also shows a significant increase in Optical Maturity parameter implying an immature regolith. The increase in SETN count rate for these craters is greater than the increase for the full set of craters by more than a factor of two.

  8. Crater Age and Hydrogen Content in Lunar Regolith from LEND Neutron Data

    NASA Technical Reports Server (NTRS)

    Starr, Richard D.; Litvak, Maxim L.; Petro, Noah E.; Mitrofanov, Igor G.; Boynton, William V.; Chin, Gordon; Livengood, Timothy A.; McClanahan, Timothy P.; Sanin, Anton B.; Sagdeev, Roald Z.; hide

    2017-01-01

    Analysis of Lunar Exploration Neutron Detector (LEND) neutron count rates for a large set of mid-latitude craters provides evidence for lower hydrogen content in the crater interiors compared to typical highland values. Epithermal neutron count rates for crater interiors measured by the LEND Sensor for Epithermal Neutrons (SETN) were compared to crater exteriors for 301 craters and displayed an increase in mean count rate at the approx. 9-sigma confidence level, consistent with a lower hydrogen content. A smaller subset of 31 craters also shows a significant increase in Optical Maturity parameter implying an immature regolith. The increase in SETN count rate for these craters is greater than the increase for the full set of craters by more than a factor of two.

  9. Relationship of milking rate to somatic cell count.

    PubMed

    Brown, C A; Rischette, S J; Schultz, L H

    1986-03-01

    Information on milking rate, monthly bucket somatic cell counts, mastitis treatment, and milk production was obtained from 284 lactations of Holstein cows separated into three lactation groups. Significant correlations between somatic cell count (linear score) and other parameters included production in lactation 1 (-.185), production in lactation 2 (-.267), and percent 2-min milk in lactation 2 (.251). Somatic cell count tended to increase with maximum milking rate in all lactations, but correlations were not statistically significant. Twenty-nine percent of cows with milking rate measurements were treated for clinical mastitis. Treated cows in each lactation group produced less milk than untreated cows. In the second and third lactation groups, treated cows had a shorter total milking time and a higher percent 2-min milk than untreated cows, but differences were not statistically significant. Overall, the data support the concept that faster milking cows tend to have higher cell counts and more mastitis treatments, particularly beyond first lactation. However, the magnitude of the relationship was small.

  10. Predictors of CD4 count over time among HIV patients initiated ART in Felege Hiwot Referral Hospital, northwest Ethiopia: multilevel analysis.

    PubMed

    Gezie, Lemma Derseh

    2016-07-30

    The response of HIV patients to antiretroviral therapy could be measured by its strong predictor, the CD4+ T cell (CD4) count for the initiation of antiretroviral therapy and proper management of disease progress. However, in addition to HIV, there are other factors which can influence the CD4 cell count. Patient's socio-economic, demographic, and behavioral variables, accessibility, duration of treatment etc., can be used to predict CD4 count. A retrospective cohort study was conducted to examine the predictors of CD4 count among ART users enrolled in the first 6 months of 2010 and followed upto mid 2014. The covariance components model was employed to determine the predictors of CD4 count over time. A total of 1196 ART attendants were used to analyze their data descriptively. Eight hundred sixty-one of the attendants had two or more CD4 count measurements and were used in modeling their data using the linear mixed method. Thus, the mean rates of incensement of CD4 counts for patients with ambulatory/bedridden and working baseline functional status were 17.4 and 30.6 cells/mm(3) per year, respectively. After adjusting for other variables, for each additional baseline CD4 count, the gain in CD4 count during treatment was 0.818 cells/mm(3) (p value <0.001). Patient's age and baseline functional status were also statistically significantly associated with CD4 count. In this study, higher baseline CD4 count, younger age, working functional status, and time in treatment contributed positively to the increment of the CD4 count. However, the observed increment at 4 year was unsatisfactory as the proportion of ART users who reached the normal range of CD4 count was very low. To see their long term treatment outcome, it requires further research with a sufficiently longer follow up data. In line with this, the local CD4 count for HIV negative persons should also be investigated for better comparison and proper disease management.

  11. Exploration of maximum count rate capabilities for large-area photon counting arrays based on polycrystalline silicon thin-film transistors

    NASA Astrophysics Data System (ADS)

    Liang, Albert K.; Koniczek, Martin; Antonuk, Larry E.; El-Mohri, Youcef; Zhao, Qihua

    2016-03-01

    Pixelated photon counting detectors with energy discrimination capabilities are of increasing clinical interest for x-ray imaging. Such detectors, presently in clinical use for mammography and under development for breast tomosynthesis and spectral CT, usually employ in-pixel circuits based on crystalline silicon - a semiconductor material that is generally not well-suited for economic manufacture of large-area devices. One interesting alternative semiconductor is polycrystalline silicon (poly-Si), a thin-film technology capable of creating very large-area, monolithic devices. Similar to crystalline silicon, poly-Si allows implementation of the type of fast, complex, in-pixel circuitry required for photon counting - operating at processing speeds that are not possible with amorphous silicon (the material currently used for large-area, active matrix, flat-panel imagers). The pixel circuits of two-dimensional photon counting arrays are generally comprised of four stages: amplifier, comparator, clock generator and counter. The analog front-end (in particular, the amplifier) strongly influences performance and is therefore of interest to study. In this paper, the relationship between incident and output count rate of the analog front-end is explored under diagnostic imaging conditions for a promising poly-Si based design. The input to the amplifier is modeled in the time domain assuming a realistic input x-ray spectrum. Simulations of circuits based on poly-Si thin-film transistors are used to determine the resulting output count rate as a function of input count rate, energy discrimination threshold and operating conditions.

  12. Incidence of Cytomegalovirus Retinitis in the Era of Highly Active Antiretroviral Therapy

    PubMed Central

    Sugar, Elizabeth A.; Jabs, Douglas A.; Ahuja, Alka; Thorne, Jennifer E.; Danis, Ronald P.; Meinert, Curtis L.

    2011-01-01

    Purpose To estimate the incidence of cytomegalovirus (CMV) retinitis in the era of highly active antiretroviral therapy (HAART) and to characterize the factors associated with increased risk of CMV retinitis. Design Prospective cohort study Methods 1600 participants with acquired immune deficiency syndrome (AIDS) but without CMV retinitis at enrollment who completed at least one follow-up visit in the Longitudinal Study of the Ocular Complications of AIDS (LSOCA) were seen every 6 months to obtain disease and treatment history, ophthalmic examination, and laboratory testing. Incidence of CMV retinitis and risk factors for incident CMV retinitis were assessed. Results The incidence rate of CMV retinitis in individuals with AIDS was 0.36/100 person years (PY) based upon 29 incident cases during 8,134 person-years of follow-up. The rate was higher for those with a CD4+ T cell count at the immediately prior visit below 50 cells/μL (3.89/100 PY, p < 0.01), whereas only one individual with a CD4+ T cell count of 50–99 cells/μL and two individuals with a CD4+ T cell count > 100 cells/μL developed CMV retinitis. Having a CD4+ T cell count below 50 cells/μL at the clinical visit prior to CMV retinitis evaluation was the single most important risk factor (HR: 136, 95% CI: 30 to 605, p < 0.0001) for developing retinitis. Conclusions Patients with AIDS, especially those with severely compromised immune systems, remain at risk for developing CMV retinitis in the HAART era, although the incidence rate is reduced from that observed in the pre-HAART era. PMID:22310076

  13. Incidence of cytomegalovirus retinitis in the era of highly active antiretroviral therapy.

    PubMed

    Sugar, Elizabeth A; Jabs, Douglas A; Ahuja, Alka; Thorne, Jennifer E; Danis, Ronald P; Meinert, Curtis L

    2012-06-01

    To estimate the incidence of cytomegalovirus (CMV) retinitis in the era of highly active antiretroviral therapy (HAART) and to characterize the factors associated with increased risk of CMV retinitis. Prospective cohort study. A total of 1600 participants with acquired immunodeficiency syndrome (AIDS) but without CMV retinitis at enrollment who completed at least 1 follow-up visit in the Longitudinal Study of the Ocular Complications of AIDS (LSOCA) were seen every 6 months to obtain disease and treatment history, ophthalmic examination, and laboratory testing. Incidence of CMV retinitis and risk factors for incident CMV retinitis were assessed. The incidence rate of CMV retinitis in individuals with AIDS was 0.36/100 person-years (PY) based upon 29 incident cases during 8134 PY of follow-up. The rate was higher for those with a CD4+ T cell count at the immediately prior visit below 50 cells/μL (3.89/100 PY, P < .01), whereas only 1 individual with a CD4+ T cell count of 50 to 99 cells/μL and 2 individuals with a CD4+ T cell count >100 cells/μL developed CMV retinitis. Having a CD4+ T cell count below 50 cells/μL at the clinical visit prior to CMV retinitis evaluation was the single most important risk factor (HR: 136, 95% CI: 30 to 605, P < .0001) for developing retinitis. Patients with AIDS, especially those with severely compromised immune systems, remain at risk for developing CMV retinitis in the HAART era, although the incidence rate is reduced from that observed in the pre-HAART era. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Method and apparatus for optimizing determination of the originating depth of borehole cuttings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mc Auley, J.A.; Eppler, S.G.

    1987-11-24

    This patent describes a method for determining the arrival at the surface of an identifiable material from a predetermined drilling depth independent of pump stroke rate and intermittent operations during the utilization of at least a drill bit, a positive displacement mud pump and drilling mud during the drilling of a well. The method comprises the steps of: adding identifiable material to the drilling mud as the drilling mud is being pumped downwardly into the well; initiate count of the pump strokes of the positive displacement mud pump as the previous step occurs; observe arrival of the identifiable material atmore » the surface of the earth as the drilling mud exits from the well; observe the accumulated count of the pump strokes of the positive displacement mud pump which occur between step one and step three; subtract, from the accumulated count of the previous step, the number of pump strokes of the positive displacement mud pump required to pump the identifiable material down to the drill bit to establish a number of lag strokes; and utilize the number obtained in the previous step to identify the arrival of drill cuttings from a predetermined depth.« less

  15. The intersection of health and wealth: association between personal bankruptcy and myocardial infarction rates in Canada.

    PubMed

    Savu, Anamaria; Schopflocher, Donald; Scholnick, Barry; Kaul, Padma

    2016-01-13

    We examined the association between personal bankruptcy filing and acute myocardial infarction (AMI) rates in Canada. Between 2002 and 2009, aggregate and yearly bankruptcy and AMI rates were estimated for 1,155 forward sortation areas of Canada. Scatter plot and correlations were used to assess the association of the aggregate rates. Cross-lagged structural equation models were used to explore the longitudinal relationship between bankruptcy and AMI after adjustment for socio-economic factors. A cross-lagged structural equation model estimated that on average, an increase of 100 in bankruptcy filing count is associated with an increase of 1.5 (p = 0.02) in AMI count in the following year, and an increase of 100 in AMI count is associated with an increase of 7 (p < 0.01) in bankruptcy filing count. We found that regions with higher rates of AMI corresponded to those with higher levels of economic and financial stress, as indicated by personal bankruptcy rate, and vice-versa.

  16. Rate for annihilation of galactic dark matter into two photons

    NASA Technical Reports Server (NTRS)

    Giudice, Gian F.; Griest, Kim

    1989-01-01

    A calculation of the cross section for neutralino-neutralino annihilation into two photons is performed and applied to dark matter in the galactic halo to find the counting rate in a large gamma ray detector such as EGRET (Energetic Gamma Ray Experiment Telescope) or ASTROGAM. Combining constraints from particle accelerators with the requirement that the neutralinos make up the dark matter, it is found that rates of over a few dozen events per year are unlikely. The assumptions that go into these conclusions are listed. Other particle dark matter candidates which could give larger and perhaps observable signals are suggested.

  17. Some haematological parameters in human immunodeficiency virus (HIV) infected Africans: the Nigerian perspective.

    PubMed

    Erhabor, O; Ejele, O A; Nwauche, C A; Buseri, F I

    2005-01-01

    Haematologic abnormalities are among the most common manifestations of advanced human immunodeficiency virus (HIV) infection and acquired immunodeficiency syndrome (AIDS). A specific diagnosis of cause, severity and mechanism of cytopenia should be sought because of specific treatments or intervention may be indicated for its correction. This study was to determine some haematological parameters in HIV/AIDS infected Nigerians. One hundred HIV/AIDS infected previously antiretroviral naïve adult Nigerians, aged 18-58 year (males 47 and females 53) consisting of 88 symptomatic and 12 asymptomatic patients recruited into the antiretroviral pilot project in the Haematology department of the University of Port Harcourt Teaching Hospital between June 2002 to July 2003 were studied. Haematological parameters of hemoglobin, white cell count, platelet count, erythrocyte sedimentation rate and differential leucocyte count were determined. Data was analyzed using a multipurpose statistical package version 9 SPSS. The mean haemoglobin was 10.25 +/- 1.97 g/dl (range 6.31-14.2 g/dl), severe anaemia occurred in 80% of subjects while 20% were non-anaemic. Haemoglobin values was found positively correlated to lymphocyte count (r = .319, P = 0.01) and inversely correlated to ESR (r = -.343, P = 0.01) and neutrophil count (r = -.343, P = 0.01). Red cell morphology was variable with majority normochromic and normocytic (64%) and 36% showing hypochromia and anisopoikilocytosis. The mean total WBC count was 4.51 +/- 1.82 x 10(9)/l (range 0.9-8.2 x 10(9)/l). Leucopaenia occurred in 10/100 (10%) of study population. Total white cell count showed a significant inverse correlation to lymphocyte count (r = -.326, P = 0.01). The mean neutrophil count was 2.32 +/- 1.58 x 10(9)/l (range 0.00-5.48). Neutropaenia occurred in 24% of subjects. Neutrophil count showed a significant positive correlation with total white cell count (r = .314, P = 0.01) and a negative correlation with lymphocyte count (r = -.982, P = 0.01). Striking eosinophilia occurred in 3% of subjects. The mean platelet count was 170.07 +/- 49.03 x 10(9)/l (range 72-158 x 268 x 10(9)/l). Thrombocytopaenia occurred in 10/100 (10%) of subjects. The mean erythrocyte sedimentation rate was higher than that in healthy Africans (mean 78.87 +/- 39.33mm fall/hour (range 0.2-158mm fall/hour). Observation from this study will serve as a guide to clinicians caring for HIV patients in taking rational decision on haematological complications of HIV infection. This constitutes further evidence of the need for routine monitoring of some haematological parameters of HIV/AIDS infected Africans and before commencement of highly active antiretroviral therapy to ensure that mortality and morbidity are minimized and quality of life optimized.

  18. [Changes and significance of peripheral blood platelet count in tumor shrinkage induced by a low dose of CTX in T739 mice].

    PubMed

    Li, Mo-lin; Jia, Yu-jie; Jiang, Miao-na; Shu, Xiao-hong; Li, Chuan-gang

    2008-06-01

    To establish a mouse model for BTT739 tumor-bearing mice cured by a low dose of cyclophosphamide (CTX). And then to observe the dynamic changes and significance of peripheral blood counts especially blood platelet count during tumor shrinkage induced by a low dose of CTX in T739 mice. Mouse bladder carcinoma tissues were inoculated subcutaneously into T739 mice. Seven days later, different doses of CTX or the same volume of NS were administered intraperitoneally to treat these tumor-bearing T739 mice. Tumor sizes were observed and recorded subsequently to find out the minimal dose of CTX that could cure most of these tumor-bearing mice. Then another 12 tumor-bearing mice were randomly divided into 15 mg/kg CTX treatment group and control group. Blood samples were obtained from orbital venous sinus on different times after CTX treatment. Complete blood counts were performed and the relationship between peripheral blood platelet counts and tumor shrinkage was analyzed. Within 2 weeks after CTX treatment, the speed of tumor shrinkage had a positive relationship with the dose of CTX used; but the survival rate of the tumor-bearing mice had a negative relationship with the dose of CTX used in 2 months after CTX treatment. 15 mg/kg CTX could cure most of the tumor bearing mice, while it had no remarkably inhibitive effects on peripheral blood cells. The perpherial platelet count increased to (1483.4+/-184.4)x10(9)/L in mice 6 h after CTX treatment. There was significant difference compared with that in mice of control group (1086.6+/-81.0)x10(9)/L (P<0.01). During the 2nd to 14th day after CTX treatment, there was no obvious difference in the platelet count between treatment group and control group (P>0.05). CTX 15 mg/kg could cure most of bladder tumor-bearing T739 mice. The transient increase of the peripheral platelet count in 6 h after CTX treatment may relate to the antitumor effects of CTX.

  19. Relationship of long-term highly active antiretroviral therapy on salivary flow rate and CD4 Count among HIV-infected patients.

    PubMed

    Kumar, J Vijay; Baghirath, P Venkat; Naishadham, P Parameswar; Suneetha, Sujai; Suneetha, Lavanya; Sreedevi, P

    2015-01-01

    To determine if long-term highly active antiretroviral therapy (HAART) therapy alters salivary flow rate and also to compare its relation of CD4 count with unstimulated and stimulated whole saliva. A cross-sectional study was performed on 150 individuals divided into three groups. Group I (50 human immunodeficiency virus (HIV) seropositive patients, but not on HAART therapy), Group II (50 HIV-infected subjects and on HAART for less than 3 years called short-term HAART), Group III (50 HIV-infected subjects and on HAART for more than or equal to 3 years called long-term HAART). Spitting method proposed by Navazesh and Kumar was used for the measurement of unstimulated and stimulated salivary flow rate. Chi-square test and analysis of variance (ANOVA) were used for statistical analysis. The mean CD4 count was 424.78 ± 187.03, 497.82 ± 206.11 and 537.6 ± 264.00 in the respective groups. Majority of the patients in all the groups had a CD4 count between 401 and 600. Both unstimulated and stimulated whole salivary (UWS and SWS) flow rates in Group I was found to be significantly higher than in Group II (P < 0.05). Unstimulated salivary flow rate between Group II and III subjects were also found to be statistically significant (P < 0.05). ANOVA performed between CD4 count and unstimulated and stimulated whole saliva in each group demonstrated a statistically significant relationship in Group II (P < 0.05). There were no significant results found between CD4 count and stimulated whole saliva in each groups. The reduction in CD4 cell counts were significantly associated with salivary flow rates of HIV-infected individuals who are on long-term HAART.

  20. Quality assurance for sperm concentration using latex beads.

    PubMed

    Peters, A J; Zaneveld, L J; Jeyendran, R S

    1993-10-01

    To provide a simple, universally applicable method of quality assurance for sperm counting, thereby reducing intercounting chamber variation. By using a known concentration of latex beads, the sperm:bead ratio can be used to calculate the actual sperm count. The mean sperm and bead counts were determined in both a Spot-lite hemocytometer (Baxter Diagnostics, McGaw Park, IL) and a Makler chamber (Polymedco Inc., Yorktown, NY) from 21 different ejaculates mixed with a known concentration of beads. The hemocytometer chamber was used as the standard counting chamber because it consistently yielded a low variation in sperm count. The adjusted sperm concentration of the Makler chamber was calculated using the following formula [hemocytometer beads]/[Makler beads] x [Makler sperm]. Observed mean +/- SD sperm counts were significantly different between the hemocytometer chamber (110.6 +/- 66.2 x 10(6)/mL) and Makler chamber (173.3 +/- 103.5 x 10(6)/mL). However, calculated Makler chamber sperm counts (118.1 +/- 76.1 x 10(6)/mL) was not statistically different from observed hemocytometer sperm counts. This novel approach to sperm counting using a known concentration of latex beads as a reference material can be used to reduce variation in sperm counting between observers, counting chambers, and possibly computerized sperm analyzers.

  1. Evaluation of two-stage system for neutron measurement aiming at increase in count rate at Japan Atomic Energy Agency-Fusion Neutronics Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shinohara, K., E-mail: shinohara.koji@jaea.go.jp; Ochiai, K.; Sukegawa, A.

    In order to increase the count rate capability of a neutron detection system as a whole, we propose a multi-stage neutron detection system. Experiments to test the effectiveness of this concept were carried out on Fusion Neutronics Source. Comparing four configurations of alignment, it was found that the influence of an anterior stage on a posterior stage was negligible for the pulse height distribution. The two-stage system using 25 mm thickness scintillator was about 1.65 times the count rate capability of a single detector system for d-D neutrons and was about 1.8 times the count rate capability for d-T neutrons.more » The results suggested that the concept of a multi-stage detection system will work in practice.« less

  2. Evaluation of Hematological Parameters in the Differentiation of Subarachnoid Hemorrhage and Other Headache Syndromes.

    PubMed

    Goktekin, Mehmet C; Yilmaz, Mustafa

    2018-06-01

    In this research, the aim was to compare hematological data for the differentiation of subarachnoid hemorrhage, migraine attack, and other headache syndromes during consultation in emergency service. In this research, which was designed as retrospective case control study, hematological parameters (WBC, HgB, HCT, PLT, lymphocyte and neutrophile counts and neutrophile/lymphocyte rates) of the patients consulting to emergency service with SAH and migraine and other consulting patients complaining mainly from headache and having normal cranial CT were analysed. Sixty migraine attack patients (F/M:47/13), 57 SAH patients (F/M:30/27), and 53 patients except migraine having normal brain CT (F/M:36/17) who were consulted to emergency service with headache complaint were included in our research. WBC, Hct, HgB, MCV, PLT, MPV, LY, Neu counts, and NY/LY rates were found to differentiate between SAH and migraine. WBC, PLT, MPV, LY, and Neu rates were found to differentiate between SAH and HS patients. Only Hct, HgB, MCV, and NY/LY rates were found to differ meaningfully between SAH and migraine patients but these rates were not found to have meaningful difference between SAH and HS patients. In addition, an increase in WBC counts and NY/LY rates and decrease in MPV counts in ROC analysis were found to be more specific for SAH. WBC, HgB, HCT, PLT, lymphocyte and Neu counts, and NY/LY rates can indicate distinguishing SAH and migraine. WBC, HgB, HCT, PLT, lymphocyte and Neu counts can indicate to the clinician a differentiation of SAH and other headache syndromes.

  3. Total airborne mold particle sampling: evaluation of sample collection, preparation and counting procedures, and collection devices.

    PubMed

    Godish, Diana; Godish, Thad

    2008-02-01

    This study was conducted to evaluate (i) procedures used to collect, prepare, and count total airborne mold spore/particle concentrations, and (ii) the relative field performance of three commercially available total airborne mold spore/particle sampling devices. Differences between factory and laboratory airflow calibration values of axial fan-driven sampling instruments (used in the study) indicated a need for laboratory calibration using a mass flow meter to ensure that sample results were accurately calculated. An aniline blue-amended Calberla's solution adjusted to a pH of 4.2-4.4 provided good sample mounting/counting results using Dow Corning high vacuum grease, Dow Corning 280A adhesive, and Dow Corning 316 silicone release spray for samples collected using mini-Burkard and Allergenco samplers. Count variability among analysts was most pronounced in 5% counts of relatively low mold particle deposition density samples and trended downward with increased count percentage and particle deposition density. No significant differences were observed among means of 5, 10, and 20% counts and among analysts; a significant interaction effect was observed between analysts' counts and particle deposition densities. Significantly higher mini-Burkard and Air-O-Cell total mold spore/particle counts for 600x vs. 400x (1.9 and 2.3 x higher, respectively), 1000x vs. 600x (1.9 and 2.2 x higher, respectively) and 1000x vs. 400x (3.6 and 4.6 x higher, respectively) comparisons indicated that 1000x magnification counts best quantified total airborne mold spore/particles using light microscopy, and that lower magnification counts may result in unacceptable underreporting of airborne mold spore/particle concentrations. Modest but significantly higher (1.2x) total mold spore concentrations were observed with Allergenco vs. mini-Burkard samples collected in co-located, concurrently operated sampler studies; moderate but significantly higher mini-Burkard count values (1.4x) were observed in similar studies with Air-O-Cell samplers. These count differences were relatively small compared with the large differences observed among three count magnifications.

  4. Multianode cylindrical proportional counter for high count rates

    DOEpatents

    Hanson, J.A.; Kopp, M.K.

    1980-05-23

    A cylindrical, multiple-anode proportional counter is provided for counting of low-energy photons (< 60 keV) at count rates of greater than 10/sup 5/ counts/sec. A gas-filled proportional counter cylinder forming an outer cathode is provided with a central coaxially disposed inner cathode and a plurality of anode wires disposed in a cylindrical array in coaxial alignment with and between the inner and outer cathodes to form a virtual cylindrical anode coaxial with the inner and outer cathodes. The virtual cylindrical anode configuration improves the electron drift velocity by providing a more uniform field strength throughout the counter gas volume, thus decreasing the electron collection time following the detection of an ionizing event. This avoids pulse pile-up and coincidence losses at these high count rates. Conventional RC position encoding detection circuitry may be employed to extract the spatial information from the counter anodes.

  5. Multianode cylindrical proportional counter for high count rates

    DOEpatents

    Hanson, James A.; Kopp, Manfred K.

    1981-01-01

    A cylindrical, multiple-anode proportional counter is provided for counting of low-energy photons (<60 keV) at count rates of greater than 10.sup.5 counts/sec. A gas-filled proportional counter cylinder forming an outer cathode is provided with a central coaxially disposed inner cathode and a plurality of anode wires disposed in a cylindrical array in coaxial alignment with and between the inner and outer cathodes to form a virtual cylindrical anode coaxial with the inner and outer cathodes. The virtual cylindrical anode configuration improves the electron drift velocity by providing a more uniform field strength throughout the counter gas volume, thus decreasing the electron collection time following the detection of an ionizing event. This avoids pulse pile-up and coincidence losses at these high count rates. Conventional RC position encoding detection circuitry may be employed to extract the spatial information from the counter anodes.

  6. Dark-count-less photon-counting x-ray computed tomography system using a YAP-MPPC detector

    NASA Astrophysics Data System (ADS)

    Sato, Eiichi; Sato, Yuich; Abudurexiti, Abulajiang; Hagiwara, Osahiko; Matsukiyo, Hiroshi; Osawa, Akihiro; Enomoto, Toshiyuki; Watanabe, Manabu; Kusachi, Shinya; Sato, Shigehiro; Ogawa, Akira; Onagawa, Jun

    2012-10-01

    A high-sensitive X-ray computed tomography (CT) system is useful for decreasing absorbed dose for patients, and a dark-count-less photon-counting CT system was developed. X-ray photons are detected using a YAP(Ce) [cerium-doped yttrium aluminum perovskite] single crystal scintillator and an MPPC (multipixel photon counter). Photocurrents are amplified by a high-speed current-voltage amplifier, and smooth event pulses from an integrator are sent to a high-speed comparator. Then, logical pulses are produced from the comparator and are counted by a counter card. Tomography is accomplished by repeated linear scans and rotations of an object, and projection curves of the object are obtained by the linear scan. The image contrast of gadolinium medium slightly fell with increase in lower-level voltage (Vl) of the comparator. The dark count rate was 0 cps, and the count rate for the CT was approximately 250 kcps.

  7. Solar particle events observed at Mars: dosimetry measurements and model calculations

    NASA Astrophysics Data System (ADS)

    Cleghorn, T.; Saganti, P.; Zeitlin, C.; Cucinotta, F.

    The first solar particle events from a Martian orbit are observed with the MARIE (Martian Radiation Environment Experiment) on the 2001 Mars Odyssey space -craft that is currently in orbit and collecting the mapping data of the red planet. These solar particle events observed at Mars during March and April 2002, are correlated with the GOES-8 and ACE satellite data from the same time period at Earth orbits. Dosimetry measurements for the Mars orbit from the period of March 13t h through April 29t h . Particle count rate and the corresponding dose rate enhancements were observed on March 16t h through 20t h and on April 22n d corresponding to solar particle events that were observed at Earth orbit on March 16t h through 21s t and beginning on April 21s t respectively. The model calculations with the HZETRN (High Z=atomic number and high Energy Transport) code estimated the background GCR (Galactic Cosmic Rays) dose rates. The dose rates observed by the MARIE instrument are within 10% of the model calculations. Dosimetry measurements and model calculation will be presented.

  8. Montana Kids Count Data Book and County Profiles, 1994.

    ERIC Educational Resources Information Center

    Healthy Mothers, Healthy Babies--The Montana Coalition, Helena.

    This Kids Count publication is the first to examine statewide trends in the well-being of Montana's children. The statistical portrait is based on 13 indicators of well-being: (1) low birthweight rate; (2) infant mortality rate; (3) child death rate; (4) teen violent death rate; (5) percent of public school enrollment in Chapter 1 programs; (6)…

  9. A real-time phoneme counting algorithm and application for speech rate monitoring.

    PubMed

    Aharonson, Vered; Aharonson, Eran; Raichlin-Levi, Katia; Sotzianu, Aviv; Amir, Ofer; Ovadia-Blechman, Zehava

    2017-03-01

    Adults who stutter can learn to control and improve their speech fluency by modifying their speaking rate. Existing speech therapy technologies can assist this practice by monitoring speaking rate and providing feedback to the patient, but cannot provide an accurate, quantitative measurement of speaking rate. Moreover, most technologies are too complex and costly to be used for home practice. We developed an algorithm and a smartphone application that monitor a patient's speaking rate in real time and provide user-friendly feedback to both patient and therapist. Our speaking rate computation is performed by a phoneme counting algorithm which implements spectral transition measure extraction to estimate phoneme boundaries. The algorithm is implemented in real time in a mobile application that presents its results in a user-friendly interface. The application incorporates two modes: one provides the patient with visual feedback of his/her speech rate for self-practice and another provides the speech therapist with recordings, speech rate analysis and tools to manage the patient's practice. The algorithm's phoneme counting accuracy was validated on ten healthy subjects who read a paragraph at slow, normal and fast paces, and was compared to manual counting of speech experts. Test-retest and intra-counter reliability were assessed. Preliminary results indicate differences of -4% to 11% between automatic and human phoneme counting. Differences were largest for slow speech. The application can thus provide reliable, user-friendly, real-time feedback for speaking rate control practice. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. HgCdTe APD-based linear-mode photon counting components and ladar receivers

    NASA Astrophysics Data System (ADS)

    Jack, Michael; Wehner, Justin; Edwards, John; Chapman, George; Hall, Donald N. B.; Jacobson, Shane M.

    2011-05-01

    Linear mode photon counting (LMPC) provides significant advantages in comparison with Geiger Mode (GM) Photon Counting including absence of after-pulsing, nanosecond pulse to pulse temporal resolution and robust operation in the present of high density obscurants or variable reflectivity objects. For this reason Raytheon has developed and previously reported on unique linear mode photon counting components and modules based on combining advanced APDs and advanced high gain circuits. By using HgCdTe APDs we enable Poisson number preserving photon counting. A metric of photon counting technology is dark count rate and detection probability. In this paper we report on a performance breakthrough resulting from improvement in design, process and readout operation enabling >10x reduction in dark counts rate to ~10,000 cps and >104x reduction in surface dark current enabling long 10 ms integration times. Our analysis of key dark current contributors suggest that substantial further reduction in DCR to ~ 1/sec or less can be achieved by optimizing wavelength, operating voltage and temperature.

  11. Efficiency of synaptic transmission of single-photon events from rod photoreceptor to rod bipolar dendrite.

    PubMed

    Schein, Stan; Ahmad, Kareem M

    2006-11-01

    A rod transmits absorption of a single photon by what appears to be a small reduction in the small number of quanta of neurotransmitter (Q(count)) that it releases within the integration period ( approximately 0.1 s) of a rod bipolar dendrite. Due to the quantal and stochastic nature of release, discrete distributions of Q(count) for darkness versus one isomerization of rhodopsin (R*) overlap. We suggested that release must be regular to narrow these distributions, reduce overlap, reduce the rate of false positives, and increase transmission efficiency (the fraction of R* events that are identified as light). Unsurprisingly, higher quantal release rates (Q(rates)) yield higher efficiencies. Focusing here on the effect of small changes in Q(rate), we find that a slightly higher Q(rate) yields greatly reduced efficiency, due to a necessarily fixed quantal-count threshold. To stabilize efficiency in the face of drift in Q(rate), the dendrite needs to regulate the biochemical realization of its quantal-count threshold with respect to its Q(count). These considerations reveal the mathematical role of calcium-based negative feedback and suggest a helpful role for spontaneous R*. In addition, to stabilize efficiency in the face of drift in degree of regularity, efficiency should be approximately 50%, similar to measurements.

  12. Assessment of children for acute respiratory infections in hospital outpatients in Tanzania: what drives good practice?

    PubMed

    Chandler, Clare I R; Nadjm, Behzad; Boniface, Gloria; Juma, Kaseem; Reyburn, Hugh; Whitty, Christopher J M

    2008-12-01

    Respiratory infections cause significant mortality in developing countries but are frequently undiagnosed. Reasons for this are unclear. We observed 1,081 outpatient consultations with patients less than five years of age in Tanzania. In 554 patients with cough or difficulty breathing, the absolute percentages examined were 5% for respiratory rate counted, 14% chest exposed, and 25% stethoscope used. Decisions to conduct particular examinations did appear to follow clinical logic, with odds ratios of 4.28 for counting respiratory rate (95% confidence interval [CI]=1.75-10.47), 2.57 for exposing the chest (95% CI=1.67-3.95), and 18.91 for using a stethoscope (95% CI=9.52-37.57) in patients with cough or difficulty breathing. Non-clinical variables, including salary level, were also associated with examinations, and history taking was more common among clinicians originating outside the hospital area. Although respiratory examinations are relatively more common in those with cough or difficulty breathing, the absolute rates are low and related to non-clinical and clinical factors.

  13. Effects of Jatropha oil on rats following 28-day oral treatment.

    PubMed

    Poon, Raymond; Valli, Victor E; Ratnayake, W M Nimal; Rigden, Marc; Pelletier, Guillaume

    2013-07-01

    Jatropha oil is an emerging feedstock for the production of biodiesels. The increasing use of this nonedible, toxic oil will result in higher potential for accidental exposures. A repeated-dose 28-day oral toxicity study was conducted to provide data for risk assessment. Jatropha oil diluted in corn oil was administered by gavage to male and female rats at 0.5, 5, 50 and 500 mg kg(-1) body weight per day for 28 consecutive days. Control rats were administered corn oil only. The growth rates and consumption of food and water were monitored. At necropsy, organs were weighed and hematological parameters assessed. Serum clinical chemistry and C-reactive protein were measured and histological examinations of organs and tissues were performed. Markedly depressed growth rate was observed in males and females receiving Jatropha oil at 500 mg kg(-1) per day. Decreased white blood cell and lymphocyte counts were detected in females at 50 and 500 mg kg(-1) per day and in males at 500 mg kg(-1) per day. These changes were correlated to mild and reversible histological changes in male and female spleens. In the liver, a mild increase in portal hepatocytes cytoplasm density was observed in males and females, while periportal vacuolation was observed exclusively in females. Mild acinar proliferation was observed in the female mammary glands at all dose levels. It is concluded that Jatropha oil produces adverse effects on female rats starting at 50 mg kg(-1) per day with decreased white blood cell and lymphocyte counts and at 500 mg kg(-1) per day in both genders in term of depressed growth rates. Copyright © 2011 John Wiley & Sons, Ltd.

  14. High Resolution Gamma Ray Spectroscopy at MHz Counting Rates With LaBr3 Scintillators for Fusion Plasma Applications

    NASA Astrophysics Data System (ADS)

    Nocente, M.; Tardocchi, M.; Olariu, A.; Olariu, S.; Pereira, R. C.; Chugunov, I. N.; Fernandes, A.; Gin, D. B.; Grosso, G.; Kiptily, V. G.; Neto, A.; Shevelev, A. E.; Silva, M.; Sousa, J.; Gorini, G.

    2013-04-01

    High resolution γ-ray spectroscopy measurements at MHz counting rates were carried out at nuclear accelerators, combining a LaBr 3(Ce) detector with dedicated hardware and software solutions based on digitization and off-line analysis. Spectra were measured at counting rates up to 4 MHz, with little or no degradation of the energy resolution, adopting a pile up rejection algorithm. The reported results represent a step forward towards the final goal of high resolution γ-ray spectroscopy measurements on a burning plasma device.

  15. [Clinical symptoms and immunology inspection characteristics of nasal cavity local allergy].

    PubMed

    Yin, Z X; Zhu, Y; Zhai, X; Zhang, J L; Liu, G

    2017-08-05

    Objective: To investigate the clinical symptoms and immunology inspection characteristics of nasal cavity local allergy. Method: Selected 60 patients as observation group, who had only nasal local allergy symptoms, allergen skin prick test and serum allergen specific IgE (SIgE) test were negative, 40 allergic rhinitis (AR) patients and 40 healthy volunteers as control groups. To detect Symptom scores and VAS scores, and eosinophilia counts in venous blood, allergen skin prick test (SPT), serum allergen SIgE test, nasal secretions allergen SIgE test, nasal mucous membrane excitation test in both observation group and AR group, eosinophilia counts in nasal secretion, taked the data for statistical analysis. Result: There was no difference ( P > 0.05) in the symptom scores and VAS scores of observation group and the AR group. The eosinophilia counts in venous blood in the AR group were higher than in the observation group ( P < 0.05). The eosinophilia counts in venous blood in the observation group were higher than in the healthy volunteers group ( P < 0.05). The positive rate of nasal secretions dust mites and pollen allergen was 90% (54/60) in observation group. There was no significant difference ( P > 0.05) in the eosinophilia percentages in nasal secretion in the observation group and the AR group. There was significant difference ( P < 0.05) in the eosinophilia percentages in nasal secretion in the observation group and the healthy volunteers group. There were 6 patients in observation group whose nasal secretions allergen SIgE test and nasal mucous membrane excitation test were both negative, could be diagnosised as non-allergic rhinitis (NAR). According to eosinophilia counts in venous blood and nasal secretions, 4 patients were diagnosised as vasomotor rhinitis and 2 patients were diagnosised as NAR with eosinophilia syndrome. There were 54 patients in observation group whose nasal secretions allergen SIgE test and (or) nasal mucous membrane excitation test were positive, could be diagnosised as local allergic rhinitis. After three years, all of the observation group patients were detected with SPT and serum allergen SIgE test. Five patients diagnosed as local allergic rhinitis before three years were positive. Six patients diagnosed as NAR before three years were negative. Conclusion: For patients with the typical medical history and symptoms of AR, but allergen SPT and serum allergen SIgE test were negative, there was local specific hypersensitivity in nasal mucosa, but the reaction was not accompanied by systemic sensitization. Combined with nasal secretions allergen SIgE test or allergen nasal mucosa proocation tests positive, could be diagnosed as local allergic rhinitis. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  16. Non-activated plasma-derived PC improves amputation rate of children undergoing sepsis.

    PubMed

    Piccin, Andrea; O' Marcaigh, Aengus; Mc Mahon, Corrina; Murphy, Ciaran; Okafor, Ikechukwu; Marcheselli, Luigi; Casey, William; Claffey, Liam; Smith, Owen Patrick

    2014-07-01

    Low circulating protein C (PC) levels have been observed in sepsis, especially in patients with Neisseriae Meningitides infections. Poor clinical outcome and high limb amputation rates have been associated in infected patients with low circulating PC levels. Published studies using activated PC replacement therapy patients with sepsis have shown reduced mortality rates, however, its use has been associated with severe bleeding events. Paediatric sepsis studies using non-activated plasma-derived PC (Ceprotin®) are lacking. We present a retrospective study in children with sepsis who were treated with Ceprotin® focusing on amputation rate post treatment. Thirty subjects were identified. Median age at diagnosis was 2 years. Twenty-one (70%) were treated for Nesseria Meningitides and one (3%) for Streptococcus-A β-haemolyticus, another 8 (26%) patients with malignancies were treated for neutropenic sepsis. Following Ceprotin® administration, a significant increase in leukocyte count (p=0.004), neutrophil count (p=0.001) and PC (pretreatment=13%, posttreatment=88.5%; p=0.0001) was seen. Prothrombin time (pretreatment =30.3 seconds, posttreatment =16.5; p=0.000) and activated partial thromboplastin time (pretreatment =61.8 sec, postreatment =42.6 sec; p=0.000) were significantly reduced, while fibrinogen levels were significantly elevated (pretreatment =1.9 g/dL, posttreatment =4.4 g/dL; p=0.000). The median time between admission to intensive care and Ceprotin® administration was 10 hrs. Limb amputation rate was reduced (16-23% versus 30-50% from previous studies) and there were no haemorrhagic events observed. This study demonstrates the safe administration of non-activated plasma-derived PC concentrate in patients with sepsis who are coagulopathic and it associated with a reduction in amputation rates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. Growth Curve Models for Zero-Inflated Count Data: An Application to Smoking Behavior

    ERIC Educational Resources Information Center

    Liu, Hui; Powers, Daniel A.

    2007-01-01

    This article applies growth curve models to longitudinal count data characterized by an excess of zero counts. We discuss a zero-inflated Poisson regression model for longitudinal data in which the impact of covariates on the initial counts and the rate of change in counts over time is the focus of inference. Basic growth curve models using a…

  18. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less

  19. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    DOE PAGES

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; ...

    2017-10-09

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less

  20. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    NASA Astrophysics Data System (ADS)

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; Hunt, Alan W.; Ludewigt, Bernhard

    2018-01-01

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ∼6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2" (length) × 2" (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ∼3 Mcps. An experimental methodology was developed that uses the average current from the PMT's anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ∼3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

  1. Observations by Juno's Radiation Monitoring Investigation During the First Year at Jupiter

    NASA Astrophysics Data System (ADS)

    Becker, H. N.; Adumitroaie, V.; Alexander, J. W.; Daubar, I.; Joergensen, J. L.; Denver, T.; Benn, M.; Adriani, A.; Mura, A.; Cicchetti, A.; Noschese, R.; Connerney, J. E. P.; Gladstone, R.; Hue, V.; Versteeg, M.; Santos-Costa, D.; Bolton, S. J.; Levin, S.; Thorne, R. M.

    2017-12-01

    Juno's Radiation Monitoring (RM) Investigation measures MeV electron fluxes at Jupiter by utilizing the noise signatures of penetrating high-energy particles which are visible in images collected by Juno's heavily shielded star cameras and science instruments. Image processing is used to identify and extract the characteristic signatures of penetrating high-energy electrons and ions and derive count rates which are used to infer external integral electron flux levels [Becker, H.N., et al. (2017), Space Sci Rev, doi: 10.1007/s11214-017-0345-9; Becker H.N. et al. (2017), Geophys. Res. Lett., 44, doi:10.1002/2017GL073091]. The count rate data from each RM instrument represents detection of electrons from within a broad energy channel (e.g. > 5 MeV or > 10 MeV electron sensitivity, determined using Geant4 shielding analysis). Simultaneous observations by the instruments therefore allow study of the external spectra where coordinated measurements are achieved. The spacecraft Stellar Reference Unit (SRU), the Magnetic Field Investigation's Advanced Stellar Compass (ASC) camera head D, and the Jovian Infrared Auroral Mapper (JIRAM) infrared imager are the primary instruments used in RM's collaborative observation campaigns. Penetrating particle signatures and trends across a broader range of Juno instruments and spacecraft housekeeping data also contribute to the analysis. This paper presents an overview of RM measurements of the Jovian high energy particle environment observed during the first eight science orbits of Juno's prime mission.

  2. THE HAWAII SCUBA-2 LENSING CLUSTER SURVEY: NUMBER COUNTS AND SUBMILLIMETER FLUX RATIOS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, Li-Yen; Cowie, Lennox L.; Barger, Amy J.

    2016-09-20

    We present deep number counts at 450 and 850 μ m using the SCUBA-2 camera on the James Clerk Maxwell Telescope. We combine data for six lensing cluster fields and three blank fields to measure the counts over a wide flux range at each wavelength. Thanks to the lensing magnification, our measurements extend to fluxes fainter than 1 mJy and 0.2 mJy at 450 μ m and 850 μ m, respectively. Our combined data highly constrain the faint end of the number counts. Integrating our counts shows that the majority of the extragalactic background light (EBL) at each wavelength ismore » contributed by faint sources with L {sub IR} < 10{sup 12} L {sub ⊙}, corresponding to luminous infrared galaxies (LIRGs) or normal galaxies. By comparing our result with the 500 μ m stacking of K -selected sources from the literature, we conclude that the K -selected LIRGs and normal galaxies still cannot fully account for the EBL that originates from sources with L {sub IR} < 10{sup 12} L {sub ⊙}. This suggests that many faint submillimeter galaxies may not be included in the UV star formation history. We also explore the submillimeter flux ratio between the two bands for our 450 μ m and 850 μ m selected sources. At 850 μ m, we find a clear relation between the flux ratio and the observed flux. This relation can be explained by a redshift evolution, where galaxies at higher redshifts have higher luminosities and star formation rates. In contrast, at 450 μ m, we do not see a clear relation between the flux ratio and the observed flux.« less

  3. Kids Count Data Book, 2003: State Profiles of Child Well-Being.

    ERIC Educational Resources Information Center

    O'Hare, William P.

    This Kids Count data book examines national and statewide trends in the well being of the nation's children. Statistical portraits are based on 10 indicators of well being: (1) percent of low birth weight babies; (2) infant mortality rate; (3) child death rate; (4) rate of teen deaths by accident, homicide, and suicide; (5) teen birth rate; (6)…

  4. KIDS COUNT Data Book, 2002: State Profiles of Child Well-Being.

    ERIC Educational Resources Information Center

    O'Hare, William P.

    This KIDS COUNT data book examines national and statewide trends in the well being of the nations children. Statistical portraits are based on 10 indicators of well being: (1) percent of low birth weight babies; (2) infant mortality rate; (3) child death rate; (4) rate of teen deaths by accident, homicide, and suicide; (5) teen birth rate; (6)…

  5. KIDS COUNT Data Book, 2001: State Profiles of Child Well-Being.

    ERIC Educational Resources Information Center

    Annie E. Casey Foundation, Baltimore, MD.

    This Kids Count report examines national and statewide trends in the well-being of the nation's children. The statistical portrait is based on 10 indicators of well being: (1) percent of low birth weight babies; (2) infant mortality rate; (3) child death rate; (4) rate of teen deaths by accident, homicide and suicide; (5) teen birth rate; (6)…

  6. Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate

    PubMed Central

    Schuck, Carsten; Pernice, Wolfram H. P.; Tang, Hong X.

    2013-01-01

    Superconducting nanowire single-photon detectors are an ideal match for integrated quantum photonic circuits due to their high detection efficiency for telecom wavelength photons. Quantum optical technology also requires single-photon detection with low dark count rate and high timing accuracy. Here we present very low noise superconducting nanowire single-photon detectors based on NbTiN thin films patterned directly on top of Si3N4 waveguides. We systematically investigate a large variety of detector designs and characterize their detection noise performance. Milli-Hz dark count rates are demonstrated over the entire operating range of the nanowire detectors which also feature low timing jitter. The ultra-low dark count rate, in combination with the high detection efficiency inherent to our travelling wave detector geometry, gives rise to a measured noise equivalent power at the 10−20 W/Hz1/2 level. PMID:23714696

  7. High resolution gamma-ray spectroscopy at high count rates with a prototype High Purity Germanium detector

    NASA Astrophysics Data System (ADS)

    Cooper, R. J.; Amman, M.; Vetter, K.

    2018-04-01

    High-resolution gamma-ray spectrometers are required for applications in nuclear safeguards, emergency response, and fundamental nuclear physics. To overcome one of the shortcomings of conventional High Purity Germanium (HPGe) detectors, we have developed a prototype device capable of achieving high event throughput and high energy resolution at very high count rates. This device, the design of which we have previously reported on, features a planar HPGe crystal with a reduced-capacitance strip electrode geometry. This design is intended to provide good energy resolution at the short shaping or digital filter times that are required for high rate operation and which are enabled by the fast charge collection afforded by the planar geometry crystal. In this work, we report on the initial performance of the system at count rates up to and including two million counts per second.

  8. LINEAR COUNT-RATE METER

    DOEpatents

    Henry, J.J.

    1961-09-01

    A linear count-rate meter is designed to provide a highly linear output while receiving counting rates from one cycle per second to 100,000 cycles per second. Input pulses enter a linear discriminator and then are fed to a trigger circuit which produces positive pulses of uniform width and amplitude. The trigger circuit is connected to a one-shot multivibrator. The multivibrator output pulses have a selected width. Feedback means are provided for preventing transistor saturation in the multivibrator which improves the rise and decay times of the output pulses. The multivibrator is connected to a diode-switched, constant current metering circuit. A selected constant current is switched to an averaging circuit for each pulse received, and for a time determined by the received pulse width. The average output meter current is proportional to the product of the counting rate, the constant current, and the multivibrator output pulse width.

  9. Reliability of joint count assessment in rheumatoid arthritis: a systematic literature review.

    PubMed

    Cheung, Peter P; Gossec, Laure; Mak, Anselm; March, Lyn

    2014-06-01

    Joint counts are central to the assessment of rheumatoid arthritis (RA) but reliability is an issue. To evaluate the reliability and agreement of joint counts (intra-observer and inter-observer) by health care professionals (physicians, nurses, and metrologists) and patients in RA, and the impact of training and standardization on joint count reliability through a systematic literature review. Articles reporting joint count reliability or agreement in RA in PubMed, EMBase, and the Cochrane library between 1960 and 2012 were selected. Data were extracted regarding tender joint counts (TJCs) and swollen joint counts (SJCs) derived by physicians, metrologists, or patients for intra-observer and inter-observer reliability. In addition, methods and effects of training or standardization were extracted. Statistics expressing reliability such as intraclass correlation coefficients (ICCs) were extracted. Data analysis was primarily descriptive due to high heterogeneity. Twenty-eight studies on health care professionals (HCP) and 20 studies on patients were included. Intra-observer reliability for TJCs and SJCs was good for HCPs and patients (range of ICC: 0.49-0.98). Inter-observer reliability between HCPs for TJCs was higher than for SJCs (range of ICC: 0.64-0.88 vs. 0.29-0.98). Patient inter-observer reliability with HCPs as comparators was better for TJCs (range of ICC: 0.31-0.91) compared to SJCs (0.16-0.64). Nine studies (7 with HCPs and 2 with patients) evaluated consensus or training, with improvement in reliability of TJCs but conflicting evidence for SJCs. Intra- and inter-observer reliability was high for TJCs for HCPs and patients: among all groups, reliability was better for TJCs than SJCs. Inter-observer reliability of SJCs was poorer for patients than HCPs. Data were inconclusive regarding the potential for training to improve SJC reliability. Overall, the results support further evaluation for patient-reported joint counts as an outcome measure. © 2013 Published by Elsevier Inc.

  10. Material screening with HPGe counting station for PandaX experiment

    NASA Astrophysics Data System (ADS)

    Wang, X.; Chen, X.; Fu, C.; Ji, X.; Liu, X.; Mao, Y.; Wang, H.; Wang, S.; Xie, P.; Zhang, T.

    2016-12-01

    A gamma counting station based on high-purity germanium (HPGe) detector was set up for the material screening of the PandaX dark matter experiments in the China Jinping Underground Laboratory. Low background gamma rate of 2.6 counts/min within the energy range of 20 to 2700 keV is achieved due to the well-designed passive shield. The sentivities of the HPGe detetector reach mBq/kg level for isotopes like K, U, Th, and even better for Co and Cs, resulted from the low-background rate and the high relative detection efficiency of 175%. The structure and performance of the counting station are described in this article. Detailed counting results for the radioactivity in materials used by the PandaX dark-matter experiment are presented. The upgrading plan of the counting station is also discussed.

  11. Surgical Space Suits Increase Particle and Microbiological Emission Rates in a Simulated Surgical Environment.

    PubMed

    Vijaysegaran, Praveen; Knibbs, Luke D; Morawska, Lidia; Crawford, Ross W

    2018-05-01

    The role of space suits in the prevention of orthopedic prosthetic joint infection remains unclear. Recent evidence suggests that space suits may in fact contribute to increased infection rates, with bioaerosol emissions from space suits identified as a potential cause. This study aimed to compare the particle and microbiological emission rates (PER and MER) of space suits and standard surgical clothing. A comparison of emission rates between space suits and standard surgical clothing was performed in a simulated surgical environment during 5 separate experiments. Particle counts were analyzed with 2 separate particle counters capable of detecting particles between 0.1 and 20 μm. An Andersen impactor was used to sample bacteria, with culture counts performed at 24 and 48 hours. Four experiments consistently showed statistically significant increases in both PER and MER when space suits are used compared with standard surgical clothing. One experiment showed inconsistent results, with a trend toward increases in both PER and MER when space suits are used compared with standard surgical clothing. Space suits cause increased PER and MER compared with standard surgical clothing. This finding provides mechanistic evidence to support the increased prosthetic joint infection rates observed in clinical studies. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Statistical approaches to the analysis of point count data: A little extra information can go a long way

    USGS Publications Warehouse

    Farnsworth, G.L.; Nichols, J.D.; Sauer, J.R.; Fancy, S.G.; Pollock, K.H.; Shriner, S.A.; Simons, T.R.; Ralph, C. John; Rich, Terrell D.

    2005-01-01

    Point counts are a standard sampling procedure for many bird species, but lingering concerns still exist about the quality of information produced from the method. It is well known that variation in observer ability and environmental conditions can influence the detection probability of birds in point counts, but many biologists have been reluctant to abandon point counts in favor of more intensive approaches to counting. However, over the past few years a variety of statistical and methodological developments have begun to provide practical ways of overcoming some of the problems with point counts. We describe some of these approaches, and show how they can be integrated into standard point count protocols to greatly enhance the quality of the information. Several tools now exist for estimation of detection probability of birds during counts, including distance sampling, double observer methods, time-depletion (removal) methods, and hybrid methods that combine these approaches. Many counts are conducted in habitats that make auditory detection of birds much more likely than visual detection. As a framework for understanding detection probability during such counts, we propose separating two components of the probability a bird is detected during a count into (1) the probability a bird vocalizes during the count and (2) the probability this vocalization is detected by an observer. In addition, we propose that some measure of the area sampled during a count is necessary for valid inferences about bird populations. This can be done by employing fixed-radius counts or more sophisticated distance-sampling models. We recommend any studies employing point counts be designed to estimate detection probability and to include a measure of the area sampled.

  13. Effects of lek count protocols on greater sage-grouse population trend estimates

    USGS Publications Warehouse

    Monroe, Adrian; Edmunds, David; Aldridge, Cameron L.

    2016-01-01

    Annual counts of males displaying at lek sites are an important tool for monitoring greater sage-grouse populations (Centrocercus urophasianus), but seasonal and diurnal variation in lek attendance may increase variance and bias of trend analyses. Recommendations for protocols to reduce observation error have called for restricting lek counts to within 30 minutes of sunrise, but this may limit the number of lek counts available for analysis, particularly from years before monitoring was widely standardized. Reducing the temporal window for conducting lek counts also may constrain the ability of agencies to monitor leks efficiently. We used lek count data collected across Wyoming during 1995−2014 to investigate the effect of lek counts conducted between 30 minutes before and 30, 60, or 90 minutes after sunrise on population trend estimates. We also evaluated trends across scales relevant to management, including statewide, within Working Group Areas and Core Areas, and for individual leks. To further evaluate accuracy and precision of trend estimates from lek count protocols, we used simulations based on a lek attendance model and compared simulated and estimated values of annual rate of change in population size (λ) from scenarios of varying numbers of leks, lek count timing, and count frequency (counts/lek/year). We found that restricting analyses to counts conducted within 30 minutes of sunrise generally did not improve precision of population trend estimates, although differences among timings increased as the number of leks and count frequency decreased. Lek attendance declined >30 minutes after sunrise, but simulations indicated that including lek counts conducted up to 90 minutes after sunrise can increase the number of leks monitored compared to trend estimates based on counts conducted within 30 minutes of sunrise. This increase in leks monitored resulted in greater precision of estimates without reducing accuracy. Increasing count frequency also improved precision. These results suggest that the current distribution of count timings available in lek count databases such as that of Wyoming (conducted up to 90 minutes after sunrise) can be used to estimate sage-grouse population trends without reducing precision or accuracy relative to trends from counts conducted within 30 minutes of sunrise. However, only 10% of all Wyoming counts in our sample (1995−2014) were conducted 61−90 minutes after sunrise, and further increasing this percentage may still bias trend estimates because of declining lek attendance. 

  14. A Persistent Disk Wind in GRS 1915+105 with NICER

    NASA Astrophysics Data System (ADS)

    Neilsen, J.; Cackett, E.; Remillard, R. A.; Homan, J.; Steiner, J. F.; Gendreau, K.; Arzoumanian, Z.; Prigozhin, G.; LaMarr, B.; Doty, J.; Eikenberry, S.; Tombesi, F.; Ludlam, R.; Kara, E.; Altamirano, D.; Fabian, A. C.

    2018-06-01

    The bright, erratic black hole X-ray binary GRS 1915+105 has long been a target for studies of disk instabilities, radio/infrared jets, and accretion disk winds, with implications that often apply to sources that do not exhibit its exotic X-ray variability. With the launch of the Neutron star Interior Composition Explorer (NICER), we have a new opportunity to study the disk wind in GRS 1915+105 and its variability on short and long timescales. Here we present our analysis of 39 NICER observations of GRS 1915+105 collected during five months of the mission data validation and verification phase, focusing on Fe XXV and Fe XXVI absorption. We report the detection of strong Fe XXVI in 32 (>80%) of these observations, with another four marginal detections; Fe XXV is less common, but both likely arise in the well-known disk wind. We explore how the properties of this wind depend on broad characteristics of the X-ray lightcurve: mean count rate, hardness ratio, and fractional rms variability. The trends with count rate and rms are consistent with an average wind column density that is fairly steady between observations but varies rapidly with the source on timescales of seconds. The line dependence on spectral hardness echoes the known behavior of disk winds in outbursts of Galactic black holes; these results clearly indicate that NICER is a powerful tool for studying black hole winds.

  15. Feasibility of a high-speed gamma-camera design using the high-yield-pileup-event-recovery method.

    PubMed

    Wong, W H; Li, H; Uribe, J; Baghaei, H; Wang, Y; Yokoyama, S

    2001-04-01

    Higher count-rate gamma cameras than are currently used are needed if the technology is to fulfill its promise in positron coincidence imaging, radionuclide therapy dosimetry imaging, and cardiac first-pass imaging. The present single-crystal design coupled with conventional detector electronics and the traditional Anger-positioning algorithm hinder higher count-rate imaging because of the pileup of gamma-ray signals in the detector and electronics. At an interaction rate of 2 million events per second, the fraction of nonpileup events is < 20% of the total incident events. Hence, the recovery of pileup events can significantly increase the count-rate capability, increase the yield of imaging photons, and minimize image artifacts associated with pileups. A new technology to significantly enhance the performance of gamma cameras in this area is introduced. We introduce a new electronic design called high-yield-pileup-event-recovery (HYPER) electronics for processing the detector signal in gamma cameras so that the individual gamma energies and positions of pileup events, including multiple pileups, can be resolved and recovered despite the mixing of signals. To illustrate the feasibility of the design concept, we have developed a small gamma-camera prototype with the HYPER-Anger electronics. The camera has a 10 x 10 x 1 cm NaI(Tl) crystal with four photomultipliers. Hot-spot and line sources with very high 99mTc activities were imaged. The phantoms were imaged continuously from 60,000 to 3,500,000 counts per second to illustrate the efficacy of the method as a function of counting rates. At 2-3 million events per second, all phantoms were imaged with little distortion, pileup, and dead-time loss. At these counting rates, multiple pileup events (> or = 3 events piling together) were the predominate occurrences, and the HYPER circuit functioned well to resolve and recover these events. The full width at half maximum of the line-spread function at 3,000,000 counts per second was 1.6 times that at 60,000 counts per second. This feasibility study showed that the HYPER electronic concept works; it can significantly increase the count-rate capability and dose efficiency of gamma cameras. In a larger clinical camera, multiple HYPER-Anger circuits may be implemented to further improve the imaging counting rates that we have shown by multiple times. This technology would facilitate the use of gamma cameras for radionuclide therapy dosimetry imaging, cardiac first-pass imaging, and positron coincidence imaging and the simultaneous acquisition of transmission and emission data using different isotopes with less cross-contamination between transmission and emission data.

  16. Essential thrombocythemia: response during first year of therapy with melphalan and radioactive phosphorus: a polycythemia Vera Study Group report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, S.; Rosenthal, D.S.; Weinfeld, A.

    1982-07-01

    Thirty-one patients with essential thrombocythemia were randomized to receive either melphalan or radioactive phosphorus as myelosuppressive therapy. Twenty-seven patients were evaluable for response. Of 13 patients treated with melphalan, 11 had a complete response (platelet count less than 450,000/mm3) at 3 and 6 months. This response rate was significantly better than the response to radioactive phosphorus. The response rates were similar at 12 months. No significant toxicity was observed with either regimen.

  17. Illinois Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Illinois' Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for Family…

  18. Accuracy of neutron self-activation method with iodine-containing scintillators for quantifying 128I generation using decay-fitting technique

    NASA Astrophysics Data System (ADS)

    Nohtomi, Akihiro; Wakabayashi, Genichiro

    2015-11-01

    We evaluated the accuracy of a self-activation method with iodine-containing scintillators in quantifying 128I generation in an activation detector; the self-activation method was recently proposed for photo-neutron on-line measurements around X-ray radiotherapy machines. Here, we consider the accuracy of determining the initial count rate R0, observed just after termination of neutron irradiation of the activation detector. The value R0 is directly related to the amount of activity generated by incident neutrons; the detection efficiency of radiation emitted from the activity should be taken into account for such an evaluation. Decay curves of 128I activity were numerically simulated by a computer program for various conditions including different initial count rates (R0) and background rates (RB), as well as counting statistical fluctuations. The data points sampled at minute intervals and integrated over the same period were fit by a non-linear least-squares fitting routine to obtain the value R0 as a fitting parameter with an associated uncertainty. The corresponding background rate RB was simultaneously calculated in the same fitting routine. Identical data sets were also evaluated by a well-known integration algorithm used for conventional activation methods and the results were compared with those of the proposed fitting method. When we fixed RB = 500 cpm, the relative uncertainty σR0 /R0 ≤ 0.02 was achieved for R0/RB ≥ 20 with 20 data points from 1 min to 20 min following the termination of neutron irradiation used in the fitting; σR0 /R0 ≤ 0.01 was achieved for R0/RB ≥ 50 with the same data points. Reasonable relative uncertainties to evaluate initial count rates were reached by the decay-fitting method using practically realistic sampling numbers. These results clarified the theoretical limits of the fitting method. The integration method was found to be potentially vulnerable to short-term variations in background levels, especially instantaneous contaminations by spike-like noise. The fitting method easily detects and removes such spike-like noise.

  19. An Evaluation of Commercial Pedometers for Monitoring Slow Walking Speed Populations.

    PubMed

    Beevi, Femina H A; Miranda, Jorge; Pedersen, Christian F; Wagner, Stefan

    2016-05-01

    Pedometers are considered desirable devices for monitoring physical activity. Two population groups of interest include patients having undergone surgery in the lower extremities or who are otherwise weakened through disease, medical treatment, or surgery procedures, as well as the slow walking senior population. For these population groups, pedometers must be able to perform reliably and accurately at slow walking speeds. The objectives of this study were to evaluate the step count accuracy of three commercially available pedometers, the Yamax (Tokyo, Japan) Digi-Walker(®) SW-200 (YM), the Omron (Kyoto, Japan) HJ-720 (OM), and the Fitbit (San Francisco, CA) Zip (FB), at slow walking speeds, specifically at 1, 2, and 3 km/h, and to raise awareness of the necessity of focusing research on step-counting devices and algorithms for slow walking populations. Fourteen participants 29.93 ±4.93 years of age were requested to walk on a treadmill at the three specified speeds, in four trials of 100 steps each. The devices were worn by the participants on the waist belt. The pedometer counts were recorded, and the error percentage was calculated. The error rate of all three evaluated pedometers decreased with the increase of speed: at 1 km/h the error rates varied from 87.11% (YM) to 95.98% (FB), at 2 km/h the error rates varied from 17.27% (FB) to 46.46% (YM), and at 3 km/h the error rates varied from 22.46% (YM) to a slight overcount of 0.70% (FB). It was observed that all the evaluated devices have high error rates at 1 km/h and mixed error rates at 2 km/h, and at 3 km/h the error rates are the smallest of the three assessed speeds, with the OM and the FB having a slight overcount. These results show that research on pedometers' software and hardware should focus more on accurate step detection at slow walking speeds.

  20. Pitch Counts in Youth Baseball and Softball: A Historical Review.

    PubMed

    Feeley, Brian T; Schisel, Jessica; Agel, Julie

    2018-07-01

    Pitching injuries are getting increased attention in the mass media. Many references are made to pitch counts and the role they play in injury prevention. The original purpose of regulating the pitch count in youth baseball was to reduce injury and fatigue to pitchers. This article reviews the history and development of the pitch count limit in baseball, the effect it has had on injury, and the evidence regarding injury rates on softball windmill pitching. Literature search through PubMed, mass media, and organizational Web sites through June 2015. Pitch count limits and rest recommendations were introduced in 1996 after a survey of 28 orthopedic surgeons and baseball coaches showed injuries to baseball pitchers' arms were believed to be from the number of pitches thrown. Follow-up research led to revised recommendations with more detailed guidelines in 2006. Since that time, data show a relationship between innings pitched and upper extremity injury, but pitch type has not clearly been shown to affect injury rates. Current surveys of coaches and players show that coaches, parents, and athletes often do not adhere to these guidelines. There are no pitch count guidelines currently available in softball. The increase in participation in youth baseball and softball with an emphasis on early sport specialization in youth sports activities suggests that there will continue to be a rise in injury rates to young throwers. The published pitch counts are likely to positively affect injury rates but must be adhered to by athletes, coaches, and parents.

  1. The influence of weather on Golden Eagle migration in northwestern Montana

    USGS Publications Warehouse

    Yates, R.E.; McClelland, B.R.; Mcclelland, P.T.; Key, C.H.; Bennetts, R.E.

    2001-01-01

    We analyzed the influence of 17 weather factors on migrating Golden Eagles (Aquila chrysaetos) near the Continental Divide in Glacier National Park, Montana, U.S.A. Local weather measurements were recorded at automated stations on the flanks of two peaks within the migration path. During a total of 506 hr of observation, the yearly number of Golden Eagles in autumn counts (1994-96) averaged 1973; spring counts (1995 and 1996) averaged 605 eagles. Mean passage rates (eagles/hr) were 16.5 in autumn and 8.2 in spring. Maximum rates were 137 in autumn and 67 in spring. Using generalized linear modeling, we tested for the effects of weather factors on the number of eagles counted. In the autumn model, the number of eagles increased with increasing air temperature, rising barometric pressure, decreasing relative humidity, and interactions among those factors. In the spring model, the number of eagles increased with increasing wind speed, barometric pressure, and the interaction between these factors. Our data suggest that a complex interaction among weather factors influenced the number of eagles passing on a given day. We hypothesize that in complex landscapes with high topographic relief, such as Glacier National Park, numerous weather factors produce different daily combinations to which migrating eagles respond opportunistically. ?? 2001 The Raptor Research Foundation, Inc.

  2. An accurate derivation of the air dose-rate and the deposition concentration distribution by aerial monitoring in a low level contaminated area

    NASA Astrophysics Data System (ADS)

    Nishizawa, Yukiyasu; Sugita, Takeshi; Sanada, Yukihisa; Torii, Tatsuo

    2015-04-01

    Since 2011, MEXT (Ministry of Education, Culture, Sports, Science and Technology, Japan) have been conducting aerial monitoring to investigate the distribution of radioactive cesium dispersed into the atmosphere after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP), Tokyo Electric Power Company. Distribution maps of the air dose-rate at 1 m above the ground and the radioactive cesium deposition concentration on the ground are prepared using spectrum obtained by aerial monitoring. The radioactive cesium deposition is derived from its dose rate, which is calculated by excluding the dose rate of the background radiation due to natural radionuclides from the air dose-rate at 1 m above the ground. The first step of the current method of calculating the dose rate due to natural radionuclides is calculate the ratio of the total count rate of areas where no radioactive cesium is detected and the count rate of regions with energy levels of 1,400 keV or higher (BG-Index). Next, calculate the air dose rate of radioactive cesium by multiplying the BG-Index and the integrated count rate of 1,400 keV or higher for the area where the radioactive cesium is distributed. In high dose-rate areas, however, the count rate of the 1,365-keV peak of Cs-134, though small, is included in the integrated count rate of 1,400 keV or higher, which could cause an overestimation of the air dose rate of natural radionuclides. We developed a method for accurately evaluating the distribution maps of natural air dose-rate by excluding the effect of radioactive cesium, even in contaminated areas, and obtained the accurate air dose-rate map attributed the radioactive cesium deposition on the ground. Furthermore, the natural dose-rate distribution throughout Japan has been obtained by this method.

  3. Radiation Discrimination in LiBaF3 Scintillator Using Digital Signal Processing Techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Bowyer, Sonya M.; Reeder, Paul L.

    2002-11-01

    The new scintillator material LiBaF3:Ce offers the possibility of measuring neutron or alpha count rates and energy spectra simultaneously while measuring gamma count rates and spectra using a single detector.

  4. 259 E Ohio, April 2014, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    The count rates for the sidewalk ranged from 5,600 cpm to 16,800 cpm.There were two locations along Ontario St. with elevated count rates approaching thethreshold limit correlating to 7.1 pCi/g total thorium.

  5. Advanced analysis techniques for uranium assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, W. H.; Ensslin, Norbert; Carrillo, L. A.

    2001-01-01

    Uranium has a negligible passive neutron emission rate making its assay practicable only with an active interrogation method. The active interrogation uses external neutron sources to induce fission events in the uranium in order to determine the mass. This technique requires careful calibration with standards that are representative of the items to be assayed. The samples to be measured are not always well represented by the available standards which often leads to large biases. A technique of active multiplicity counting is being developed to reduce some of these assay difficulties. Active multiplicity counting uses the measured doubles and triples countmore » rates to determine the neutron multiplication (f4) and the product of the source-sample coupling ( C ) and the 235U mass (m). Since the 35U mass always appears in the multiplicity equations as the product of Cm, the coupling needs to be determined before the mass can be known. A relationship has been developed that relates the coupling to the neutron multiplication. The relationship is based on both an analytical derivation and also on empirical observations. To determine a scaling constant present in this relationship, known standards must be used. Evaluation of experimental data revealed an improvement over the traditional calibration curve analysis method of fitting the doubles count rate to the 235Um ass. Active multiplicity assay appears to relax the requirement that the calibration standards and unknown items have the same chemical form and geometry.« less

  6. Comparison of GEANT4 Physics Models with Measured Beta Particle Data in Aluminum using a Strontium-90 Source

    NASA Astrophysics Data System (ADS)

    Everett, Samantha

    2010-10-01

    A transmission curve experiment was carried out to measure the range of beta particles in aluminum in the health physics laboratory located on the campus of Texas Southern University. The transmission count rate through aluminum for varying radiation lengths was measured using beta particles emitted from a low activity (˜1 μCi) Sr-90 source. The count rate intensity was recorded using a Geiger Mueller tube (SGC N210/BNC) with an active volume of 61 cm^3 within a systematic detection accuracy of a few percent. We compared these data with a realistic simulation of the experimental setup using the Geant4 Monte Carlo toolkit (version 9.3). The purpose of this study was to benchmark our Monte Carlo for future experiments as part of a more comprehensive research program. Transmission curves were simulated based on the standard and low-energy electromagnetic physics models, and using the radioactive decay module for the electrons primary energy distribution. To ensure the validity of our measurements, linear extrapolation techniques were employed to determine the in-medium beta particle range from the measured data and was found to be 1.87 g/cm^2 (˜0.693 cm), in agreement with literature values. We found that the general shape of the measured data and simulated curves were comparable; however, a discrepancy in the relative count rates was observed. The origin of this disagreement is still under investigation.

  7. Using Crater Counts to Constrain Erosion Rates on Mars: Implications for the Global Dust Cycle, Sedimentary Rock Erosion and Organic Matter Preservation

    NASA Astrophysics Data System (ADS)

    Mayer, D. P.; Kite, E. S.

    2016-12-01

    Sandblasting, aeolian infilling, and wind deflation all obliterate impact craters on Mars, complicating the use of crater counts for chronology, particularly on sedimentary rock surfaces. However, crater counts on sedimentary rocks can be exploited to constrain wind erosion rates. Relatively small, shallow craters are preferentially obliterated as a landscape undergoes erosion, so the size-frequency distribution of impact craters in a landscape undergoing steady exhumation will develop a shallower power-law slope than a simple production function. Estimating erosion rates is important for several reasons: (1) Wind erosion is a source of mass for the global dust cycle, so the global dust reservoir will disproportionately sample fast-eroding regions; (2) The pace and pattern of recent wind erosion is a sorely-needed constraint on models of the sculpting of Mars' sedimentary-rock mounds; (3) Near-surface complex organic matter on Mars is destroyed by radiation in <108 years, so high rates of surface exhumation are required for preservation of near-surface organic matter. We use crater counts from 18 HiRISE images over sedimentary rock deposits as the basis for estimating erosion rates. Each image was counted by ≥3 analysts and only features agreed on by ≥2 analysts were included in the erosion rate estimation. Erosion rates range from 0.1-0.2 {μ }m/yr across all images. These rates represent an upper limit on surface erosion by landscape lowering. At the conference we will discuss the within and between-image variability of erosion rates and their implications for recent geological processes on Mars.

  8. Dynamic time-correlated single-photon counting laser ranging

    NASA Astrophysics Data System (ADS)

    Peng, Huan; Wang, Yu-rong; Meng, Wen-dong; Yan, Pei-qin; Li, Zhao-hui; Li, Chen; Pan, Hai-feng; Wu, Guang

    2018-03-01

    We demonstrate a photon counting laser ranging experiment with a four-channel single-photon detector (SPD). The multi-channel SPD improve the counting rate more than 4×107 cps, which makes possible for the distance measurement performed even in daylight. However, the time-correlated single-photon counting (TCSPC) technique cannot distill the signal easily while the fast moving targets are submersed in the strong background. We propose a dynamic TCSPC method for fast moving targets measurement by varying coincidence window in real time. In the experiment, we prove that targets with velocity of 5 km/s can be detected according to the method, while the echo rate is 20% with the background counts of more than 1.2×107 cps.

  9. Influence of observers and stream flow on northern two-lined salamander (Eurycea bislineata bislineata) relative abundance estimates in Acadia and Shenandoah National Parks, USA

    USGS Publications Warehouse

    Crocker, J.B.; Bank, M.S.; Loftin, C.S.; Jung Brown, R.E.

    2007-01-01

    We investigated effects of observers and stream flow on Northern Two-Lined Salamander (Eurycea bislineata bislineata) counts in streams in Acadia (ANP) and Shenandoah National Parks (SNP). We counted salamanders in 22 ANP streams during high flow (May to June 2002) and during low flow (July 2002). We also counted salamanders in SNP in nine streams during high flow (summer 2003) and 11 streams during low flow (summers 2001?02, 2004). In 2002, we used a modified cover-controlled active search method with a first and second observer. In succession, observers turned over 100 rocks along five 1-m belt transects across the streambed. The difference between observers in total salamander counts was not significant. We counted fewer E. b. bislineata during high flow conditions, confirming that detection of this species is reduced during high flow periods and that assessment of stream salamander relative abundance is likely more reliable during low or base flow conditions.

  10. Haematolohical profile of subacute oral toxicity of molybdenum and ameliorative efficacy of copper salt in goats.

    PubMed

    Kusum; Raina, R; Verma, P K; Pankaj, N K; Kant, V; Kumar, J; Srivastava, A K

    2010-07-01

    Molybdenum toxicity produces a state of secondary hypocuprosis, resulting into alterations in normal hematological profile. In the present study, ammonium molybdate alone and with copper sulfate (II) pentahydrate (ameliorative agent) was administered orally for 30 consecutive days in healthy goats of group 1 and 2, respectively, to access the effect on the hematological profile on different predetermined days of dosing. Administration of ammonium molybdate alone produced significant decline in the mean values of hemoglobin (Hb), packed cell volume (PCV), total leukocyte count (TLC), total erythrocyte count (TEC), and mean corpuscular hemoglobin concentration (MCHC), with a significant increase in neutrophil level and mean corpuscular volume (MCV). However, values of erythrocyte sedimentation rate, mean corpuscular hemoglobin, and differential leukocyte count were not significantly altered. On comparing observations of ameliorative group with the group 1 goats, it is concluded that the ameliorative copper salt has beneficial effects in alleviating the alterations in the values of Hb, PCV, TLC, TEC, MCV, MCHC, and neutrophils.

  11. Haematolohical Profile of Subacute Oral Toxicity of Molybdenum and Ameliorative Efficacy of Copper Salt in Goats

    PubMed Central

    Kusum; Raina, R.; Verma, P. K.; Pankaj, N. K.; Kant, V.; Kumar, J.; Srivastava, A. K.

    2010-01-01

    Molybdenum toxicity produces a state of secondary hypocuprosis, resulting into alterations in normal hematological profile. In the present study, ammonium molybdate alone and with copper sulfate (II) pentahydrate (ameliorative agent) was administered orally for 30 consecutive days in healthy goats of group 1 and 2, respectively, to access the effect on the hematological profile on different predetermined days of dosing. Administration of ammonium molybdate alone produced significant decline in the mean values of hemoglobin (Hb), packed cell volume (PCV), total leukocyte count (TLC), total erythrocyte count (TEC), and mean corpuscular hemoglobin concentration (MCHC), with a significant increase in neutrophil level and mean corpuscular volume (MCV). However, values of erythrocyte sedimentation rate, mean corpuscular hemoglobin, and differential leukocyte count were not significantly altered. On comparing observations of ameliorative group with the group 1 goats, it is concluded that the ameliorative copper salt has beneficial effects in alleviating the alterations in the values of Hb, PCV, TLC, TEC, MCV, MCHC, and neutrophils. PMID:21170251

  12. Pulse shape discrimination of Cs2LiYCl6:Ce3+ detectors at high count rate based on triangular and trapezoidal filters

    NASA Astrophysics Data System (ADS)

    Wen, Xianfei; Enqvist, Andreas

    2017-09-01

    Cs2LiYCl6:Ce3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. A disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. They are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

  13. Trend estimation in populations with imperfect detection

    USGS Publications Warehouse

    Kery, Marc; Dorazio, Robert M.; Soldaat, Leo; Van Strien, Arco; Zuiderwijk, Annie; Royle, J. Andrew

    2009-01-01

    1. Trends of animal populations are of great interest in ecology but cannot be directly observed owing to imperfect detection. Binomial mixture models use replicated counts to estimate abundance, corrected for detection, in demographically closed populations. Here, we extend these models to open populations and illustrate them using sand lizard Lacerta agilis counts from the national Dutch reptile monitoring scheme. 2. Our model requires replicated counts from multiple sites in each of several periods, within which population closure is assumed. Counts are described by a hierarchical generalized linear model, where the state model deals with spatio-temporal patterns in true abundance and the observation model with imperfect counts, given that true state. We used WinBUGS to fit the model to lizard counts from 208 transects with 1–10 (mean 3) replicate surveys during each spring 1994–2005. 3. Our state model for abundance contained two independent log-linear Poisson regressions on year for coastal and inland sites, and random site effects to account for unexplained heterogeneity. The observation model for detection of an individual lizard contained effects of region, survey date, temperature, observer experience and random survey effects. 4. Lizard populations increased in both regions but more steeply on the coast. Detectability increased over the first few years of the study, was greater on the coast and for the most experienced observers, and highest around 1 June. Interestingly, the population increase inland was not detectable when the observed counts were analysed without account of detectability. The proportional increase between 1994 and 2005 in total lizard abundance across all sites was estimated at 86% (95% CRI 35–151). 5. Synthesis and applications. Open-population binomial mixture models are attractive for studying true population dynamics while explicitly accounting for the observation process, i.e. imperfect detection. We emphasize the important conceptual benefit provided by temporal replicate observations in terms of the interpretability of animal counts.

  14. Systematic measurement of fast neutron background fluctuations in an urban area using a mobile detection system

    DOE PAGES

    Iyengar, Anagha; Beach, Matthew; Newby, Robert J.; ...

    2015-11-12

    Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reductionmore » in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.« less

  15. 355 E Riverwalk, February 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 2,600 cpm to 4,300 cpm. No count rates were found at any time that exceeded the threshold limit of 7,029 cpm.

  16. 230 E. Ontario, May 2018, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,800 cpm to 2,600 cpm.No count rates were found at any time that exceeded the threshold limit of 7,366 cpm.

  17. Apparatus and method for temperature correction and expanded count rate of inorganic scintillation detectors

    DOEpatents

    Ianakiev, Kiril D [Los Alamos, NM; Hsue, Sin Tao [Santa Fe, NM; Browne, Michael C [Los Alamos, NM; Audia, Jeffrey M [Abiquiu, NM

    2006-07-25

    The present invention includes an apparatus and corresponding method for temperature correction and count rate expansion of inorganic scintillation detectors. A temperature sensor is attached to an inorganic scintillation detector. The inorganic scintillation detector, due to interaction with incident radiation, creates light pulse signals. A photoreceiver processes the light pulse signals to current signals. Temperature correction circuitry that uses a fast light component signal, a slow light component signal, and the temperature signal from the temperature sensor to corrected an inorganic scintillation detector signal output and expanded the count rate.

  18. Relationship between salivary flow rates and Candida counts in subjects with xerostomia.

    PubMed

    Torres, Sandra R; Peixoto, Camila Bernardo; Caldas, Daniele Manhães; Silva, Eline Barboza; Akiti, Tiyomi; Nucci, Márcio; de Uzeda, Milton

    2002-02-01

    This study evaluated the relationship between salivary flow and Candida colony counts in the saliva of patients with xerostomia. Sialometry and Candida colony-forming unit (CFU) counts were taken from 112 subjects who reported xerostomia in a questionnaire. Chewing-stimulated whole saliva was collected and streaked in Candida plates and counted in 72 hours. Species identification was accomplished under standard methods. There was a significant inverse relationship between salivary flow and Candida CFU counts (P =.007) when subjects with high colony counts were analyzed (cutoff point of 400 or greater CFU/mL). In addition, the median sialometry of men was significantly greater than that of women (P =.003), even after controlling for confounding variables like underlying disease and medications. Sjögren's syndrome was associated with low salivary flow rate (P =.007). There was no relationship between the median Candida CFU counts and gender or age. There was a high frequency (28%) of mixed colonization. Candida albicans was the most frequent species, followed by C parapsilosis, C tropicalis, and C krusei. In subjects with high Candida CFU counts there was an inverse relationship between salivary flow and Candida CFU counts.

  19. Power counting to better jet observables

    NASA Astrophysics Data System (ADS)

    Larkoski, Andrew J.; Moult, Ian; Neill, Duff

    2014-12-01

    Optimized jet substructure observables for identifying boosted topologies will play an essential role in maximizing the physics reach of the Large Hadron Collider. Ideally, the design of discriminating variables would be informed by analytic calculations in perturbative QCD. Unfortunately, explicit calculations are often not feasible due to the complexity of the observables used for discrimination, and so many validation studies rely heavily, and solely, on Monte Carlo. In this paper we show how methods based on the parametric power counting of the dynamics of QCD, familiar from effective theory analyses, can be used to design, understand, and make robust predictions for the behavior of jet substructure variables. As a concrete example, we apply power counting for discriminating boosted Z bosons from massive QCD jets using observables formed from the n-point energy correlation functions. We show that power counting alone gives a definite prediction for the observable that optimally separates the background-rich from the signal-rich regions of phase space. Power counting can also be used to understand effects of phase space cuts and the effect of contamination from pile-up, which we discuss. As these arguments rely only on the parametric scaling of QCD, the predictions from power counting must be reproduced by any Monte Carlo, which we verify using Pythia 8 and Herwig++. We also use the example of quark versus gluon discrimination to demonstrate the limits of the power counting technique.

  20. THE NEW HORIZONS SOLAR WIND AROUND PLUTO (SWAP) OBSERVATIONS OF THE SOLAR WIND FROM 11–33 au

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Elliott, H. A.; McComas, D. J.; Valek, P.

    The Solar Wind Around Pluto (SWAP) instrument on National Aeronautics and Space Administration's New Horizons Pluto mission has collected solar wind observations en route from Earth to Pluto, and these observations continue beyond Pluto. Few missions have explored the solar wind in the outer heliosphere making this dataset a critical addition to the field. We created a forward model of SWAP count rates, which includes a comprehensive instrument response function based on laboratory and flight calibrations. By fitting the count rates with this model, the proton density (n), speed (V), and temperature (T) parameters are determined. Comparisons between SWAP parametersmore » and both propagated 1 au observations and prior Voyager 2 observations indicate consistency in both the range and mean wind values. These comparisons as well as our additional findings confirm that small and midsized solar wind structures are worn down with increasing distance due to dynamic interaction of parcels of wind with different speed. For instance, the T–V relationship steepens, as the range in V is limited more than the range in T with distance. At times the T–V correlation clearly breaks down beyond 20 au, which may indicate wind currently expanding and cooling may have an elevated T reflecting prior heating and compression in the inner heliosphere. The power of wind parameters at shorter periodicities decreases with distance as the longer periodicities strengthen. The solar rotation periodicity is present in temperature beyond 20 au indicating the observed parcel temperature may reflect not only current heating or cooling, but also heating occurring closer to the Sun.« less

  1. Comparing census methods for the endangered Kirtland's Warbler

    Treesearch

    John R. Probst; Deahn M. Donner; Mike Worland; Jerry Weinrich; Phillip Huber; Kenneth R. Ennis

    2005-01-01

    We compared transect counts used for the annual official count of male Kirtland`s Warblers (Dendroica kirtlandii) to an observation-based mapping method of individually sighted males in 155 stands over 10 yrs. The annual census count almost tripled from 1990 to 1999. The transect and observation-based mapping method showed the same increasing trend...

  2. Platelet count recovery and seroreversion in immune HIT despite continuation of heparin: further observations and literature review.

    PubMed

    Shih, Andrew W; Sheppard, Jo-Ann I; Warkentin, Theodore E

    2017-10-05

    One of the standard distinctions between type 1 (non-immune) and type 2 (immune-mediated) heparin-induced thrombocytopenia (HIT) is the transience of thrombocytopenia: type 1 HIT is viewed as early-onset and transient thrombocytopenia, with platelet count recovery despite continuing heparin administration. In contrast, type 2 HIT is viewed as later-onset (i. e., 5 days or later) thrombocytopenia in which it is generally believed that platelet count recovery will not occur unless heparin is discontinued. However, older reports of type 2 HIT sometimes did include the unexpected observation that platelet counts could recover despite continued heparin administration, although without information provided regarding changes in HIT antibody levels in association with platelet count recovery. In recent years, some reports of type 2 HIT have confirmed the observation that platelet count recovery can occur despite continuing heparin administration, with serological evidence of waning levels of HIT antibodies ("seroreversion"). We now report two additional patient cases of type 2 HIT with platelet count recovery despite ongoing therapeutic-dose (1 case) or prophylactic-dose (1 case) heparin administration, in which we demonstrate concomitant waning of HIT antibody levels. We further review the literature describing this phenomenon of HIT antibody seroreversion and platelet count recovery despite continuing heparin administration. Our observations add to the concept that HIT represents a remarkably transient immune response, including sometimes even when heparin is continued.

  3. OPTHYLIC: An Optimised Tool for Hybrid Limits Computation

    NASA Astrophysics Data System (ADS)

    Busato, Emmanuel; Calvet, David; Theveneaux-Pelzer, Timothée

    2018-05-01

    A software tool, computing observed and expected upper limits on Poissonian process rates using a hybrid frequentist-Bayesian CLs method, is presented. This tool can be used for simple counting experiments where only signal, background and observed yields are provided or for multi-bin experiments where binned distributions of discriminating variables are provided. It allows the combination of several channels and takes into account statistical and systematic uncertainties, as well as correlations of systematic uncertainties between channels. It has been validated against other software tools and analytical calculations, for several realistic cases.

  4. Residential Proximity to Agricultural Pesticide Use and Incidence of Breast Cancer in California, 1988–1997

    PubMed Central

    Reynolds, Peggy; Hurley, Susan E.; Gunier, Robert B.; Yerabati, Sauda; Quach, Thu; Hertz, Andrew

    2005-01-01

    California is the largest agricultural state in the United States and home to some of the world’s highest breast cancer rates. The objective of our study was to evaluate whether California breast cancer rates were elevated in areas with recent high agricultural pesticide use. We identified population-based invasive breast cancer cases from the California Cancer Registry for 1988–1997. We used California’s pesticide use reporting data to select pesticides for analysis based on use volume, carcinogenic potential, and exposure potential. Using 1990 and 2000 U.S. Census data, we derived age- and race-specific population counts for the time period of interest. We used a geographic information system to aggregate cases, population counts, and pesticide use data for all block groups in the state. To evaluate whether breast cancer rates were related to recent agricultural pesticide use, we computed rate ratios and 95% confidence intervals using Poisson regression models, adjusting for age, race/ethnicity, and neighborhood socioeconomic status and urbanization. This ecologic (aggregative) analysis included 176,302 invasive breast cancer cases and 70,968,598 person-years of observation. The rate ratios did not significantly differ from 1 for any of the selected pesticide categories or individual agents. The results from this study provide no evidence that California women living in areas of recent, high agricultural pesticide use experience higher rates of breast cancer. PMID:16079069

  5. Kids Count Data Sheet, 2000.

    ERIC Educational Resources Information Center

    Annie E. Casey Foundation, Baltimore, MD.

    Data from the 50 United States are listed for 1997 from Kids Count in an effort to track state-by-state the status of children in the United States and to secure better futures for all children. Data include percent low birth weight babies; infant mortality rate; child death rate; rate of teen deaths by accident, homicide, and suicide; teen birth…

  6. Palm Beach Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Palm Beach's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  7. Miami-Dade Quality Counts: QRS Profile. The Child Care Quality Rating System (QRS) Assessment

    ERIC Educational Resources Information Center

    Child Trends, 2010

    2010-01-01

    This paper presents a profile of Miami-Dade's Quality Counts prepared as part of the Child Care Quality Rating System (QRS) Assessment Study. The profile consists of several sections and their corresponding descriptions including: (1) Program Information; (2) Rating Details; (3) Quality Indicators for Center-Based Programs; (4) Indicators for…

  8. A Comparison of Bird Detection Rates Derived from On-Road vs. Off-Road Point Counts in Northern Montana

    Treesearch

    Richard L. Hutto; Sallie J. Hejl; Jeffrey F. Kelly; Sandra M. Pletschet

    1995-01-01

    We conducted a series of 275 paired (on- and off-road) point counts within 4 distinct vegetation cover types in northwestern Montana. Roadside counts generated a bird list that was essentially the same as the list generated from off-road counts within the same vegetation cover type. Species that were restricted to either on- or off-road counts were rare, suggesting...

  9. Late HIV diagnosis is a major risk factor for intensive care unit admission in HIV-positive patients: a single centre observational cohort study

    PubMed Central

    2013-01-01

    Background HIV positive patients are at risk of infectious and non-infectious complications that may necessitate intensive care unit (ICU) admission. While the characteristics of patients requiring ICU admission have been described previously, these studies did not include information on the denominator population from which these cases arose. Methods We conducted an observational cohort study of ICU admissions among 2751 HIV positive patients attending King’s College Hospital, South London, UK. Poisson regression models were used to identify factors associated with ICU admission. Results The overall incidence rate of ICU admission was 1.0 [95% CI 0.8, 1.2] per 100 person-years of follow up, and particularly high early (during the first 3 months) following HIV diagnosis (12.4 [8.7, 17.3] per 100 person-years compared to 0.37 [0.27, 0.50] per 100 person-years thereafter; incidence rate ratio 33.5 [23.4, 48.1], p < 0.001). In time-updated analyses, AIDS and current CD4 cell counts of less than 200 cells/mm3 were associated with an increased incidence of ICU admission while receipt of combination antiretroviral therapy (cART) was associated with a reduced incidence of ICU admission. Late HIV diagnosis (initial CD4 cell count <350 or AIDS within 3 months of HIV diagnosis) applied to 81% of patients who were first diagnosed HIV positive during the study period and who required ICU admission. Late HIV diagnosis was significantly associated with ICU admission in the first 3 months following HIV diagnosis (adjusted incidence rate ratio 8.72, 95% CI 2.76, 27.5). Conclusions Late HIV diagnosis was a major risk factor for early ICU admission in our cohort. Earlier HIV diagnosis allowing cART initiation at CD4 cell counts of 350 cells/mm3 is likely to have a significant impact on the need for ICU care. PMID:23331544

  10. Integration of manatee life-history data and population modeling

    USGS Publications Warehouse

    Eberhardt, L.L.; O'Shea, Thomas J.; O'Shea, Thomas J.; Ackerman, B.B.; Percival, H. Franklin

    1995-01-01

    Aerial counts and the number of deaths have been a major focus of attention in attempts to understand the population status of the Florida manatee (Trichechus manatus latirostris). Uncertainties associated with these data have made interpretation difficult. However, knowledge of manatee life-history attributes increased and now permits the development of a population model. We describe a provisional model based on the classical approach of Lotka. Parameters in the model are based on data from'other papers in this volume and draw primarily on observations from the Crystal River, Blue Spring, and Adantic Coast areas. The model estimates X (the finite rate ofincrease) at each study area, and application ofthe delta method provides estimates of variance components and partial derivatives ofX with respectto key input parameters (reproduction, adult survival, and early survival). In some study areas, only approximations of some parameters are available. Estimates of X and coefficients of variation (in parentheses) of manatees were 1.07 (0.009) in the Crystal River, 1.06 (0.012) at Blue Spring, and 1.01 (0.012) on the Atlantic Coast. Changing adult survival has a major effect on X. Early-age survival has the smallest effect. Bootstrap comparisons of population growth estimates from trend counts in the Crystal River and at Blue Spring and the reproduction and survival data suggest that the higher, observed rates from counts are probably not due to chance. Bootstrapping for variance estimates based on reproduction and survival data from manatees at Blue Spring and in the Crystal River provided estimates of X, adult survival, and rates of reproduction that were similar to those obtained by other methods. Our estimates are preliminary and suggestimprovements for future data collection and analysis. However, results support efforts to reduce mortality as the most effective means to promote the increased growth necessary for the eventual recovery of the Florida manatee population.

  11. Between-monitor differences in step counts are related to body size: implications for objective physical activity measurement.

    PubMed

    Pomeroy, Jeremy; Brage, Søren; Curtis, Jeffrey M; Swan, Pamela D; Knowler, William C; Franks, Paul W

    2011-04-27

    The quantification of the relationships between walking and health requires that walking is measured accurately. We correlated different measures of step accumulation to body size, overall physical activity level, and glucose regulation. Participants were 25 men and 25 women American Indians without diabetes (Age: 20-34 years) in Phoenix, Arizona, USA. We assessed steps/day during 7 days of free living, simultaneously with three different monitors (Accusplit-AX120, MTI-ActiGraph, and Dynastream-AMP). We assessed total physical activity during free-living with doubly labeled water combined with resting metabolic rate measured by expired gas indirect calorimetry. Glucose tolerance was determined during an oral glucose tolerance test. Based on observed counts in the laboratory, the AMP was the most accurate device, followed by the MTI and the AX120, respectively. The estimated energy cost of 1000 steps per day was lower in the AX120 than the MTI or AMP. The correlation between AX120-assessed steps/day and waist circumference was significantly higher than the correlation between AMP steps and waist circumference. The difference in steps per day between the AX120 and both the AMP and the MTI were significantly related to waist circumference. Between-monitor differences in step counts influence the observed relationship between walking and obesity-related traits.

  12. Flow rate calibration to determine cell-derived microparticles and homogeneity of blood components.

    PubMed

    Noulsri, Egarit; Lerdwana, Surada; Kittisares, Kulvara; Palasuwan, Attakorn; Palasuwan, Duangdao

    2017-08-01

    Cell-derived microparticles (MPs) are currently of great interest to screening transfusion donors and blood components. However, the current approach to counting MPs is not affordable for routine laboratory use due to its high cost. The current study aimed to investigate the potential use of flow-rate calibration for counting MPs in whole blood, packed red blood cells (PRBCs), and platelet concentrates (PCs). The accuracy of flow-rate calibration was investigated by comparing the platelet counts of an automated counter and a flow-rate calibrator. The concentration of MPs and their origins in whole blood (n=100), PRBCs (n=100), and PCs (n=92) were determined using a FACSCalibur. The MPs' fold-changes were calculated to assess the homogeneity of the blood components. Comparing the platelet counts conducted by automated counting and flow-rate calibration showed an r 2 of 0.6 (y=0.69x+97,620). The CVs of the within-run and between-run variations of flow-rate calibration were 8.2% and 12.1%, respectively. The Bland-Altman plot showed a mean bias of -31,142platelets/μl. MP enumeration revealed both the difference in MP levels and their origins in whole blood, PRBCs, and PCs. Screening the blood components demonstrated high heterogeneity of the MP levels in PCs when compared to whole blood and PRBCs. The results of the present study suggest the accuracy and precision of flow-rate calibration for enumerating MPs. This flow-rate approach is affordable for assessing the homogeneity of MPs in blood components in routine laboratory practice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Effect of distance-related heterogeneity on population size estimates from point counts

    USGS Publications Warehouse

    Efford, Murray G.; Dawson, Deanna K.

    2009-01-01

    Point counts are used widely to index bird populations. Variation in the proportion of birds counted is a known source of error, and for robust inference it has been advocated that counts be converted to estimates of absolute population size. We used simulation to assess nine methods for the conduct and analysis of point counts when the data included distance-related heterogeneity of individual detection probability. Distance from the observer is a ubiquitous source of heterogeneity, because nearby birds are more easily detected than distant ones. Several recent methods (dependent double-observer, time of first detection, time of detection, independent multiple-observer, and repeated counts) do not account for distance-related heterogeneity, at least in their simpler forms. We assessed bias in estimates of population size by simulating counts with fixed radius w over four time intervals (occasions). Detection probability per occasion was modeled as a half-normal function of distance with scale parameter sigma and intercept g(0) = 1.0. Bias varied with sigma/w; values of sigma inferred from published studies were often 50% for a 100-m fixed-radius count. More critically, the bias of adjusted counts sometimes varied more than that of unadjusted counts, and inference from adjusted counts would be less robust. The problem was not solved by using mixture models or including distance as a covariate. Conventional distance sampling performed well in simulations, but its assumptions are difficult to meet in the field. We conclude that no existing method allows effective estimation of population size from point counts.

  14. 371 E. Lower Wacker Drive, March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,600 cpm to 2,600 cpm.No count rates were found at any time that exceeded the threshold limit of 7,029 cpm.

  15. 220 E. Illinois St., March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,500 cpm to 5,600 cpm.No count rates were found at any time that exceeded the threshold limit of 7,029 cpm.

  16. 8-37 W. Hubbard, March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,800 cpm to 5,200 cpm. No count rates were found at any time that exceeded the threshold limit of 7,389 cpm.

  17. 429 E. Grand Ave, March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,700 cpm to 3,700 cpm.No count rates were found at any time that exceeded the threshold limit of 7,029 cpm.

  18. 201-211 E. Grand Ave, January 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,700 cpm to 3,900 cpm. No count rates were found at any time that exceeded the threshold limit of 7,029 cpm.

  19. 230 N. Michigan Ave, April 2018, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,400 cpm to 3,800 cpm. No count rates were found at any time that exceeded the threshold limit of 6,542 cpm.

  20. 36 W. Illinois St, March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,800 cpm to 2,400 cpm.No count rates were found at any time that exceeded the threshold limit of 7,029 cpm.

  1. 1-37 W. Hubbard, March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,800 cpm to 5,000 cpm. No count rates were found at any time that exceeded the threshold limit of 7,389 cpm.

  2. 211 E. Ohio St., March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,700 cpm to 2,300 cpm.No count rates were found at any time that exceeded the threshold limit of 6,338 cpm.

  3. 140-200 E. Grand Ave, February 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,700 cpm to 2,400 cpm. No count rates were found at any time that exceeded the threshold limit of 6,738 cpm.

  4. 430 N. Michigan Ave, January 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,600 cpm to 2,100 cpm. No count rates were found at any time that exceeded the threshold limit of 6,338 cpm.

  5. 401-599 N. Dearborn St., March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation, The count rates in the excavation ranged from 1,700 cpm to 5,800 cpm.No count rates were found at any time that exceeded the threshold limit of 6,738 cpm.

  6. Neutronic analysis of the 1D and 1E banks reflux detection system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blanchard, A.

    1999-12-21

    Two H Canyon neutron monitoring systems for early detection of postulated abnormal reflux conditions in the Second Uranium Cycle 1E and 1D Mixer-Settle Banks have been designed and built. Monte Carlo neutron transport simulations using the general purpose, general geometry, n-particle MCNP code have been performed to model expected response of the monitoring systems to varying conditions.The confirmatory studies documented herein conclude that the 1E and 1D neutron monitoring systems are able to achieve adequate neutron count rates for various neutron source and detector configurations, thereby eliminating excessive integration count time. Neutron count rate sensitivity studies are also performed. Conversely,more » the transport studies concluded that the neutron count rates are statistically insensitive to nitric acid content in the aqueous region and to the transition region length. These studies conclude that the 1E and 1D neutron monitoring systems are able to predict the postulated reflux conditions for all examined perturbations in the neutron source and detector configurations. In the cases examined, the relative change in the neutron count rates due to postulated transitions from normal {sup 235}U concentration levels to reflux levels remain satisfactory detectable.« less

  7. Validity of Different Activity Monitors to Count Steps in an Inpatient Rehabilitation Setting.

    PubMed

    Treacy, Daniel; Hassett, Leanne; Schurr, Karl; Chagpar, Sakina; Paul, Serene S; Sherrington, Catherine

    2017-05-01

    Commonly used activity monitors have been shown to be accurate in counting steps in active people; however, further validation is needed in slower walking populations. To determine the validity of activity monitors for measuring step counts in rehabilitation inpatients compared with visually observed step counts. To explore the influence of gait parameters, activity monitor position, and use of walkers on activity monitor accuracy. One hundred and sixty-six inpatients admitted to a rehabilitation unit with an average walking speed of 0.4 m/s (SD 0.2) wore 16 activity monitors (7 different devices in different positions) simultaneously during 6-minute and 6-m walks. The number of steps taken during the tests was also counted by a physical therapist. Gait parameters were assessed using the GAITRite system. To analyze the influence of different gait parameters, the percentage accuracy for each monitor was graphed against various gait parameters for each activity monitor. The StepWatch, Fitbit One worn on the ankle and the ActivPAL showed excellent agreement with observed step count (ICC 2,1 0.98; 0.92; 0.78 respectively). Other devices (Fitbit Charge, Fitbit One worn on hip, G-Sensor, Garmin Vivofit, Actigraph) showed poor agreement with the observed step count (ICC 2,1 0.12-0.40). Percentage agreement with observed step count was highest for the StepWatch (mean 98%). The StepWatch and the Fitbit One worn on the ankle maintained accuracy in individuals who walked more slowly and with shorter strides but other devices were less accurate in these individuals. There were small numbers of participants for some gait parameters. The StepWatch showed the highest accuracy and closest agreement with observed step count. This device can be confidently used by researchers for accurate measurement of step counts in inpatient rehabilitation in individuals who walk slowly. If immediate feedback is desired, the Fitbit One when worn on the ankle would be the best choice for this population. © 2017 American Physical Therapy Association

  8. Mortality and morbidity among HIV type-1-infected patients during the first 5 years of a multicountry HIV workplace programme in Africa.

    PubMed

    Van der Borght, Stefaan F; Clevenbergh, Philippe; Rijckborst, Henk; Nsalou, Paul; Onyia, Ngozi; Lange, Joep M; de Wit, Tobias F Rinke; Van der Loeff, Maarten F Schim

    2009-01-01

    This study aimed to evaluate the effectiveness of an HIV workplace programme in sub-Saharan Africa. The international brewing company, Heineken, introduced an HIV workplace programme in its African subsidiaries in 2001. Beneficiaries from 16 sites in 5 countries were eligible. HIV type-1 (HIV-1)-infected individuals were assessed clinically and immunologically, and started highly active antiretroviral therapy (HAART) if they had AIDS or had a CD4+ T-cell count <300 cells/microl. In this cohort, study patients were followed-up for vital status, new AIDS events, CD4+ T-cell count and haemoglobin. Over the first 5 years of the programme, 431 adults were found to be HIV-1-infected. The mortality rate among those not yet taking HAART was 2.6 per 100 person-years of observation (pyo). By October 2006, 249 patients had started HAART at a median CD4+ T-cell count of 170 cells/microl; 59 (23.7%) patients were in CDC stage C. Among patients on HAART, 25 died and 7 were lost to follow-up. The mortality rate was 3.7 per 100 pyo overall, 14 per 100 pyo in the first 16 weeks and 2.5 per 100 pyo thereafter (P < 0.0001). At 4 years after start of treatment, 89% of patients were known to be alive. The CD4+ T-cell count increased by a median of 153 and 238 cells/microl after 1 and 4 years of HAART, respectively. In this HIV workplace programme in sub-Saharan Africa, long-term high survival was achieved.

  9. Calibration and correction procedures for cosmic-ray neutron soil moisture probes located across Australia

    NASA Astrophysics Data System (ADS)

    Hawdon, Aaron; McJannet, David; Wallace, Jim

    2014-06-01

    The cosmic-ray probe (CRP) provides continuous estimates of soil moisture over an area of ˜30 ha by counting fast neutrons produced from cosmic rays which are predominantly moderated by water molecules in the soil. This paper describes the setup, measurement correction procedures, and field calibration of CRPs at nine locations across Australia with contrasting soil type, climate, and land cover. These probes form the inaugural Australian CRP network, which is known as CosmOz. CRP measurements require neutron count rates to be corrected for effects of atmospheric pressure, water vapor pressure changes, and variations in incoming neutron intensity. We assess the magnitude and importance of these corrections and present standardized approaches for network-wide analysis. In particular, we present a new approach to correct for incoming neutron intensity variations and test its performance against existing procedures used in other studies. Our field calibration results indicate that a generalized calibration function for relating neutron counts to soil moisture is suitable for all soil types, with the possible exception of very sandy soils with low water content. Using multiple calibration data sets, we demonstrate that the generalized calibration function only applies after accounting for persistent sources of hydrogen in the soil profile. Finally, we demonstrate that by following standardized correction procedures and scaling neutron counting rates of all CRPs to a single reference location, differences in calibrations between sites are related to site biomass. This observation provides a means for estimating biomass at a given location or for deriving coefficients for the calibration function in the absence of field calibration data.

  10. Incidence of Non-AIDS-Defining Malignancies in HIV-Infected Vs. Non-Infected Patients in the HAART Era: Impact of Immunosuppression

    PubMed Central

    Bedimo, Roger J.; McGinnis, Kathleen A.; Dunlap, Melinda; Rodriguez-Barradas, Maria C.; Justice, Amy C.

    2009-01-01

    Background The incidence of non-AIDS-defining malignancies (non-ADM) is reported as unchanged or increasing in the HAART era. Whether incidence of non-ADM is significantly higher in HIV-infected than in HIV-uninfected patients remains unclear. Methods Incidence rates of malignancies were calculated in a cohort of veterans in care for HIV-infected and age, race, and gender-matched uninfected patients from 1997 to 2004. For HIV-infected patients CD4 counts closest to first observation date were compared between those with and without cancer. Results 33,420 HIV-infected and 66,840 HIV-uninfected patients were followed for a median of 5.1 and 6.4 years. The Incidence rate ratio [IRR] of HIV-infected to HIV-uninfected was 1.6 (1260 vs. 841/100,000 person-years; 95% CI: 1.5–1.7). IRR for individual cancers was highest for anal cancer (14.9; CI: 10.1–22.1). Among HIV-infected patients, median CD4 counts were lower for those with non-ADM (249 vs. 270, p=0.02), anal cancer (154 vs. 270; p<0.001), and Hodgkin’s (217 vs. 270; p=0.03). Prostate cancer was associated with a higher CD4 count (310 vs. 270; p<0.001). Conclusions In the HAART era, the incidence of non-ADMs is higher among HIV-infected than HIV-uninfected patients, adjusting for age, race, and gender. Some non-ADMs do not appear to be associated with significantly lower CD4 counts. PMID:19617846

  11. A removal model for estimating detection probabilities from point-count surveys

    USGS Publications Warehouse

    Farnsworth, G.L.; Pollock, K.H.; Nichols, J.D.; Simons, T.R.; Hines, J.E.; Sauer, J.R.

    2002-01-01

    Use of point-count surveys is a popular method for collecting data on abundance and distribution of birds. However, analyses of such data often ignore potential differences in detection probability. We adapted a removal model to directly estimate detection probability during point-count surveys. The model assumes that singing frequency is a major factor influencing probability of detection when birds are surveyed using point counts. This may be appropriate for surveys in which most detections are by sound. The model requires counts to be divided into several time intervals. Point counts are often conducted for 10 min, where the number of birds recorded is divided into those first observed in the first 3 min, the subsequent 2 min, and the last 5 min. We developed a maximum-likelihood estimator for the detectability of birds recorded during counts divided into those intervals. This technique can easily be adapted to point counts divided into intervals of any length. We applied this method to unlimited-radius counts conducted in Great Smoky Mountains National Park. We used model selection criteria to identify whether detection probabilities varied among species, throughout the morning, throughout the season, and among different observers. We found differences in detection probability among species. Species that sing frequently such as Winter Wren (Troglodytes troglodytes) and Acadian Flycatcher (Empidonax virescens) had high detection probabilities (∼90%) and species that call infrequently such as Pileated Woodpecker (Dryocopus pileatus) had low detection probability (36%). We also found detection probabilities varied with the time of day for some species (e.g. thrushes) and between observers for other species. We used the same approach to estimate detection probability and density for a subset of the observations with limited-radius point counts.

  12. Predictive accuracy of particle filtering in dynamic models supporting outbreak projections.

    PubMed

    Safarishahrbijari, Anahita; Teyhouee, Aydin; Waldner, Cheryl; Liu, Juxin; Osgood, Nathaniel D

    2017-09-26

    While a new generation of computational statistics algorithms and availability of data streams raises the potential for recurrently regrounding dynamic models with incoming observations, the effectiveness of such arrangements can be highly subject to specifics of the configuration (e.g., frequency of sampling and representation of behaviour change), and there has been little attempt to identify effective configurations. Combining dynamic models with particle filtering, we explored a solution focusing on creating quickly formulated models regrounded automatically and recurrently as new data becomes available. Given a latent underlying case count, we assumed that observed incident case counts followed a negative binomial distribution. In accordance with the condensation algorithm, each such observation led to updating of particle weights. We evaluated the effectiveness of various particle filtering configurations against each other and against an approach without particle filtering according to the accuracy of the model in predicting future prevalence, given data to a certain point and a norm-based discrepancy metric. We examined the effectiveness of particle filtering under varying times between observations, negative binomial dispersion parameters, and rates with which the contact rate could evolve. We observed that more frequent observations of empirical data yielded super-linearly improved accuracy in model predictions. We further found that for the data studied here, the most favourable assumptions to make regarding the parameters associated with the negative binomial distribution and changes in contact rate were robust across observation frequency and the observation point in the outbreak. Combining dynamic models with particle filtering can perform well in projecting future evolution of an outbreak. Most importantly, the remarkable improvements in predictive accuracy resulting from more frequent sampling suggest that investments to achieve efficient reporting mechanisms may be more than paid back by improved planning capacity. The robustness of the results on particle filter configuration in this case study suggests that it may be possible to formulate effective standard guidelines and regularized approaches for such techniques in particular epidemiological contexts. Most importantly, the work tentatively suggests potential for health decision makers to secure strong guidance when anticipating outbreak evolution for emerging infectious diseases by combining even very rough models with particle filtering method.

  13. Point Count Length and Detection of Forest Neotropical Migrant Birds

    Treesearch

    Deanna K. Dawson; David R. Smith; Chandler S. Robbins

    1995-01-01

    Comparisons of bird abundances among years or among habitats assume that the rates at which birds are detected and counted are constant within species. We use point count data collected in forests of the Mid-Atlantic states to estimate detection probabilities for Neotropical migrant bird species as a function of count length. For some species, significant differences...

  14. Integrating data from multiple sources for insights into demographic processes: Simulation studies and proof of concept for hierarchical change-in-ratio models.

    PubMed

    Nilsen, Erlend B; Strand, Olav

    2018-01-01

    We developed a model for estimating demographic rates and population abundance based on multiple data sets revealing information about population age- and sex structure. Such models have previously been described in the literature as change-in-ratio models, but we extend the applicability of the models by i) using time series data allowing the full temporal dynamics to be modelled, by ii) casting the model in an explicit hierarchical modelling framework, and by iii) estimating parameters based on Bayesian inference. Based on sensitivity analyses we conclude that the approach developed here is able to obtain estimates of demographic rate with high precision whenever unbiased data of population structure are available. Our simulations revealed that this was true also when data on population abundance are not available or not included in the modelling framework. Nevertheless, when data on population structure are biased due to different observability of different age- and sex categories this will affect estimates of all demographic rates. Estimates of population size is particularly sensitive to such biases, whereas demographic rates can be relatively precisely estimated even with biased observation data as long as the bias is not severe. We then use the models to estimate demographic rates and population abundance for two Norwegian reindeer (Rangifer tarandus) populations where age-sex data were available for all harvested animals, and where population structure surveys were carried out in early summer (after calving) and late fall (after hunting season), and population size is counted in winter. We found that demographic rates were similar regardless whether we include population count data in the modelling, but that the estimated population size is affected by this decision. This suggest that monitoring programs that focus on population age- and sex structure will benefit from collecting additional data that allow estimation of observability for different age- and sex classes. In addition, our sensitivity analysis suggests that focusing monitoring towards changes in demographic rates might be more feasible than monitoring abundance in many situations where data on population age- and sex structure can be collected.

  15. A compact 7-cell Si-drift detector module for high-count rate X-ray spectroscopy.

    PubMed

    Hansen, K; Reckleben, C; Diehl, I; Klär, H

    2008-05-01

    A new Si-drift detector module for fast X-ray spectroscopy experiments was developed and realized. The Peltier-cooled module comprises a sensor with 7 × 7-mm 2 active area, an integrated circuit for amplification, shaping and detection, storage, and derandomized readout of signal pulses in parallel, and amplifiers for line driving. The compactness and hexagonal shape of the module with a wrench size of 16mm allow very short distances to the specimen and multi-module arrangements. The power dissipation is 186mW. At a shaper peaking time of 190 ns and an integration time of 450 ns an electronic rms noise of ~11 electrons was achieved. When operated at 7 °C, FWHM line widths around 260 and 460 eV (Cu-K α ) were obtained at low rates and at sum-count rates of 1.7 MHz, respectively. The peak shift is below 1% for a broad range of count rates. At 1.7-MHz sum-count rate the throughput loss amounts to 30%.

  16. Acoustic Emission Parameters of Three Gorges Sandstone during Shear Failure

    NASA Astrophysics Data System (ADS)

    Xu, Jiang; Liu, Yixin; Peng, Shoujian

    2016-12-01

    In this paper, an experimental investigation of sandstone samples from the Three Gorges during shear failure was conducted using acoustic emission (AE) and direct shear tests. The AE count rate, cumulative AE count, AE energy, and amplitude of the sandstone samples were determined. Then, the relationships among the AE signals and shearing behaviors of the samples were analyzed in order to detect micro-crack initiation and propagation and reflect shear failure. The results indicated that both the shear strength and displacement exhibited a logarithmic relationship with the displacement rate at peak levels of stress. In addition, the various characteristics of the AE signals were apparent in various situations. The AE signals corresponded with the shear stress under different displacement rates. As the displacement rate increased, the amount of accumulative damage to each specimen decreased, while the AE energy peaked earlier and more significantly. The cumulative AE count primarily increased during the post-peak period. Furthermore, the AE count rate and amplitude exhibited two peaks during the peak shear stress period due to crack coalescence and rock bridge breakage. These isolated cracks later formed larger fractures and eventually caused ruptures.

  17. Radiation measurement above the lunar surface by Kaguya gamma-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Hasebe, Nobuyuki; Nagaoka, Hiroshi; Kusano, Hiroki; Hareyama, Matoko; Ideguchi, Yusuke; Shimizu, Sota; Shibamura, Eido

    The lunar surface is filled with various ionizing radiations such as high energy galactic particles, albedo particles and secondary radiations of neutrons, gamma rays and other elementary particles. A high-resolution Kaguya Gamma-Ray Spectrometer (KGRS) was carried on the Japan’s lunar explorer SELENE (Kaguya), the largest lunar orbiter since the Apollo missions. The KGRS instrument employed, for the first time in lunar exploration, a high-purity Ge crystal to increase the identification capability of elemental gamma-ray lines. The Ge detector is surrounded by BGO and plastic counters as for anticoincidence shields. The KGRS measured gamma rays in the energy range from 200 keV to 13 MeV with high precision to determine the chemical composition of the lunar surface. It provided data on the abundance of major elements over the entire lunar surface. In addition to the gamma-ray observation by the KGRS, it successfully measured the global distribution of fast neutrons. In the energy spectra of gamma-rays observed by the KGRS, several saw-tooth- peaks of Ge are included, which are formed by the collision interaction of lunar fast neutrons with Ge atoms in the Ge crystal. With these saw-tooth-peaks analysis, global distribution of neutrons emitted from the lunara surface was successfully created, which was compared with the previous results obtained by Lunar Prospector neutron maps. Another anticoincidence counter, the plastic counter with 5 mm thickness, was used to veto radiation events mostly generated by charged particles. A single photomultiplier serves to count scintillation light from the plastic scintillation counter. The global map of counting rates observed by the plastic counter was also created, implying that the radiation counting rate implies the geological distribution, in spite that the plastic counter mostly measures high energy charged particles and energetic neutrons. These results are presented and discussed.

  18. Partial bisulfite conversion for unique template sequencing

    PubMed Central

    Kumar, Vijay; Rosenbaum, Julie; Wang, Zihua; Forcier, Talitha; Ronemus, Michael; Wigler, Michael

    2018-01-01

    Abstract We introduce a new protocol, mutational sequencing or muSeq, which uses sodium bisulfite to randomly deaminate unmethylated cytosines at a fixed and tunable rate. The muSeq protocol marks each initial template molecule with a unique mutation signature that is present in every copy of the template, and in every fragmented copy of a copy. In the sequenced read data, this signature is observed as a unique pattern of C-to-T or G-to-A nucleotide conversions. Clustering reads with the same conversion pattern enables accurate count and long-range assembly of initial template molecules from short-read sequence data. We explore count and low-error sequencing by profiling 135 000 restriction fragments in a PstI representation, demonstrating that muSeq improves copy number inference and significantly reduces sporadic sequencer error. We explore long-range assembly in the context of cDNA, generating contiguous transcript clusters greater than 3,000 bp in length. The muSeq assemblies reveal transcriptional diversity not observable from short-read data alone. PMID:29161423

  19. Temporal trends of time to antiretroviral treatment initiation, interruption and modification: examination of patients diagnosed with advanced HIV in Australia.

    PubMed

    Wright, Stephen T; Law, Matthew G; Cooper, David A; Keen, Phillip; McDonald, Ann; Middleton, Melanie; Woolley, Ian; Kelly, Mark; Petoumenos, Kathy

    2015-01-01

    HIV prevention strategies are moving towards reducing plasma HIV RNA viral load in all HIV-positive persons, including those undiagnosed, treatment naïve, on or off antiretroviral therapy. A proxy population for those undiagnosed are patients that present late to care with advanced HIV. The objectives of this analysis are to examine factors associated with patients presenting with advanced HIV, and establish rates of treatment interruption and modification after initiating ART. We deterministically linked records from the Australian HIV Observational Database to the Australian National HIV Registry to obtain information related to HIV diagnosis. Logistic regression was used to identify factors associated with advanced HIV diagnosis. We used survival methods to evaluate rates of ART initiation by diagnosis CD4 count strata and by calendar year of HIV diagnosis. Cox models were used to determine hazard of first ART treatment interruption (duration >30 days) and time to first major ART modification. Factors associated (p<0.05) with increased odds of advanced HIV diagnosis were sex, older age, heterosexual mode of HIV exposure, born overseas and rural-regional care setting. Earlier initiation of ART occurred at higher rates in later periods (2007-2012) in all diagnosis CD4 count groups. We found an 83% (69, 91%) reduction in the hazard of first treatment interruption comparing 2007-2012 versus 1996-2001 (p<0.001), and no difference in ART modification for patients diagnosed with advanced HIV. Recent HIV diagnoses are initiating therapy earlier in all diagnosis CD4 cell count groups, potentially lowering community viral load compared to earlier time periods. We found a marked reduction in the hazard of first treatment interruption, and found no difference in rates of major modification to ART by HIV presentation status in recent periods.

  20. Issues to Be Considered in Counting Burrows as a Measure of Atlantic Ghost Crab Populations, an Important Bioindicator of Sandy Beaches

    PubMed Central

    Pombo, Maíra; Turra, Alexander

    2013-01-01

    The use of indirect estimates of ghost-crab populations to assess beach disturbance has several advantages, including non-destructiveness, ease and low cost, although this strategy may add some degree of noise to estimates of population parameters. Resolution of these shortcomings may allow wider use of these populations as an indicator of differences in quality among beaches. This study analyzed to what extent the number of crab burrows may diverge from the number of animals, considering beach morphology, burrow depth and signs of occupation as contributing factors or indicators of a higher or lower occupation rate. We estimated the occupation rate of crabs in burrows on nine low-use beaches, which were previously categorized as dissipative, intermediate or reflexive. Three random 2-m-wide transects were laid perpendicular to the shoreline, where burrows were counted and excavated to search for crabs. The depth and signs of recent activity around the burrows were also recorded. The occupation rate differed on the different beaches, but morphodynamics was not identified as a grouping factor. A considerable number of burrows that lacked signs of recent activity proved to be occupied, and the proportions of these burrows also differed among beaches. Virtually all burrows less than 10 cm deep were unoccupied; the occupation rate tended to increase gradually to a burrow depth of 20–35 cm. Other methods (water, smoke, and traps) were applied to measure the effectiveness of excavating as a method for burrow counts. Traps and excavation proved to be the best methods. These observations illustrate the possible degree of unreliability of comparisons of beaches based on indirect measures. Combining burrow depth assessment with surrounding signs of occupation proved to be a useful tool to minimize biases. PMID:24376748

  1. Laboratory productivity and the rate of manual peripheral blood smear review: a College of American Pathologists Q-Probes study of 95,141 complete blood count determinations performed in 263 institutions.

    PubMed

    Novis, David A; Walsh, Molly; Wilkinson, David; St Louis, Mary; Ben-Ezra, Jonathon

    2006-05-01

    Automated laboratory hematology analyzers are capable of performing differential counts on peripheral blood smears with greater precision and more accurate detection of distributional and morphologic abnormalities than those performed by manual examinations of blood smears. Manual determinations of blood morphology and leukocyte differential counts are time-consuming, expensive, and may not always be necessary. The frequency with which hematology laboratory workers perform manual screens despite the availability of labor-saving features of automated analyzers is unknown. To determine the normative rates with which manual peripheral blood smears were performed in clinical laboratories, to examine laboratory practices associated with higher or lower manual review rates, and to measure the effects of manual smear review on the efficiency of generating complete blood count (CBC) determinations. From each of 3 traditional shifts per day, participants were asked to select serially, 10 automated CBC specimens, and to indicate whether manual scans and/or reviews with complete differential counts were performed on blood smears prepared from those specimens. Sampling continued until a total of 60 peripheral smears were reviewed manually. For each specimen on which a manual review was performed, participants indicated the patient's age, hemoglobin value, white blood cell count, platelet count, and the primary reason why the manual review was performed. Participants also submitted data concerning their institutions' demographic profiles and their laboratories' staffing, work volume, and practices regarding CBC determinations. The rates of manual reviews and estimations of efficiency in performing CBC determinations were obtained from the data. A total of 263 hospitals and independent laboratories, predominantly located in the United States, participating in the College of American Pathologists Q-Probes Program. There were 95,141 CBC determinations examined in this study; participants reviewed 15,423 (16.2%) peripheral blood smears manually. In the median institution (50th percentile), manual reviews of peripheral smears were performed on 26.7% of specimens. Manual differential count review rates were inversely associated with the magnitude of platelet counts that were required by laboratory policy to trigger smear reviews and with the efficiency of generating CBC reports. Lower manual differential count review rates were associated with laboratory policies that allowed manual reviews solely on the basis of abnormal automated red cell parameters and that precluded performing repeat manual reviews within designated time intervals. The manual scan rate elevated with increased number of hospital beds. In more than one third (35.7%) of the peripheral smears reviewed manually, participants claimed to have learned additional information beyond what was available on automated hematology analyzer printouts alone. By adopting certain laboratory practices, it may be possible to reduce the rates of manual reviews of peripheral blood smears and increase the efficiency of generating CBC results.

  2. Linear-log counting-rate meter uses transconductance characteristics of a silicon planar transistor

    NASA Technical Reports Server (NTRS)

    Eichholz, J. J.

    1969-01-01

    Counting rate meter compresses a wide range of data values, or decades of current. Silicon planar transistor, operating in the zero collector-base voltage mode, is used as a feedback element in an operational amplifier to obtain the log response.

  3. The use of noise equivalent count rate and the NEMA phantom for PET image quality evaluation.

    PubMed

    Yang, Xin; Peng, Hao

    2015-03-01

    PET image quality is directly associated with two important parameters among others: count-rate performance and image signal-to-noise ratio (SNR). The framework of noise equivalent count rate (NECR) was developed back in the 1990s and has been widely used since then to evaluate count-rate performance for PET systems. The concept of NECR is not entirely straightforward, however, and among the issues requiring clarification are its original definition, its relationship to image quality, and its consistency among different derivation methods. In particular, we try to answer whether a higher NECR measurement using a standard NEMA phantom actually corresponds to better imaging performance. The paper includes the following topics: 1) revisiting the original analytical model for NECR derivation; 2) validating three methods for NECR calculation based on the NEMA phantom/standard; and 3) studying the spatial dependence of NECR and quantitative relationship between NECR and image SNR. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. Extreme Ultraviolet Explorer Bright Source List

    NASA Technical Reports Server (NTRS)

    Malina, Roger F.; Marshall, Herman L.; Antia, Behram; Christian, Carol A.; Dobson, Carl A.; Finley, David S.; Fruscione, Antonella; Girouard, Forrest R.; Hawkins, Isabel; Jelinsky, Patrick

    1994-01-01

    Initial results from the analysis of the Extreme Ultraviolet Explorer (EUVE) all-sky survey (58-740 A) and deep survey (67-364 A) are presented through the EUVE Bright Source List (BSL). The BSL contains 356 confirmed extreme ultraviolet (EUV) point sources with supporting information, including positions, observed EUV count rates, and the identification of possible optical counterparts. One-hundred twenty-six sources have been detected longward of 200 A.

  5. Anthropogenic food provisioning and immune phenotype: Association among supplemental food, body condition, and immunological parameters in urban environments.

    PubMed

    Hwang, Jusun; Kim, Yongbaek; Lee, Sang-Won; Kim, Na-Yon; Chun, Myung-Sun; Lee, Hang; Gottdenker, Nicole

    2018-03-01

    Direct or indirect supplemental feeding of free-ranging animals occurs worldwide, resulting in significant impacts on population density or altered demographic processes. Another potential impact of increased energy intake from supplemental feeding is altered immunocompetence. As immune system maintenance is energetically costly, there may be trade-offs between immune responses and other energy-demanding physiological processes in individual animals. Although increased availability of food sources through supplemental feeding is expected to increase the overall immunocompetence of animals, empirical data verifying the association between supplemental feeding and different immune parameters are lacking. Understanding the potential influence of supplemental feeding on immune phenotypes is critical, as it may also impact host-pathogen dynamics in free-ranging animals. Using urban stray cats as a study model, we tested for associations between the intensity of supplemental feeding due to cat caretaker activity (CCA); body condition; and immune phenotype (bacterial killing assay (BKA), immunoglobulin G (IgG) concentration, and leukocyte counts). Significantly higher bacterial killing ability was observed in cats from high CCA districts, whereas higher IgG concentration and eosinophil counts were observed in cats from low CCA districts. Other leukocyte counts and body condition indices showed no significant association with CCA. We observed varying patterns of different immune components in relation to supplemental feeding. Out data suggest that supplemental feeding influences immune phenotype, not only by means of energy provisioning, but also by potentially reducing exposure rates to parasite infections through stray cat behavioral changes.

  6. Effect of Pumpkin Seed Oil on Hair Growth in Men with Androgenetic Alopecia: A Randomized, Double-Blind, Placebo-Controlled Trial

    PubMed Central

    Jeong, Dong Wook; Choi, Eun Jung; Kim, Yun Jin; Lee, Jeong Gyu; Yi, Yu Hyeon; Cha, Hyeong Soo

    2014-01-01

    Pumpkin seed oil (PSO) has been shown to block the action of 5-alpha reductase and to have antiandrogenic effects on rats. This randomized, placebo-controlled, double-blind study was designed to investigate the efficacy and tolerability of PSO for treatment of hair growth in male patients with mild to moderate androgenetic alopecia (AGA). 76 male patients with AGA received 400 mg of PSO per day or a placebo for 24 weeks. Change over time in scalp hair growth was evaluated by four outcomes: assessment of standardized clinical photographs by a blinded investigator; patient self-assessment scores; scalp hair thickness; and scalp hair counts. Reports of adverse events were collected throughout the study. After 24 weeks of treatment, self-rated improvement score and self-rated satisfaction scores in the PSO-treated group were higher than in the placebo group (P = 0.013, 0.003). The PSO-treated group had more hair after treatment than at baseline, compared to the placebo group (P < 0.001). Mean hair count increases of 40% were observed in PSO-treated men at 24 weeks, whereas increases of 10% were observed in placebo-treated men (P < 0.001). Adverse effects were not different in the two groups. PMID:24864154

  7. Viability of the Lactobacillus rhamnosus HN001 probiotic strain in Swiss- and Dutch-type cheese and cheese-like products.

    PubMed

    Cichosz, Grażyna; Aljewicz, Marek; Nalepa, Beata

    2014-06-01

    The objective of this study was to determine the viability of the probiotic Lactobacillus rhamnosus HN001 in Swiss-type and Dutch-type cheese and cheese-like products (milk fat is substituted by stearin fraction of palm fat) during manufacture, ripening, and storage. The use of the probiotic L. rhamnosus HN001 in Dutch-type cheese and cheese-like products significantly (P = 0.1) changed their chemical composition (protein and fat content) and an insignificant increase (approximately 1.6% in cheese-like products and approximately 0.3% in cheese) in yield. L. rhamnosus HN001 did not affect the rate of changes in the pH of ripened cheese and cheese-like products. A minor increase in probiotic counts was observed in initial stages of production and were partially removed with whey. Ripened cheese and cheese-like products were characterized by high survival rates of probiotic bacteria which exceeded 8 log CFU/g after ripening. An insignificant reduction in the number of viable probiotic cells was noted during storage of Swiss-type and Dutch-type cheese, whereas a significant increase in probiotic cell counts was observed in cheese-like products during storage. © 2014 Institute of Food Technologists®

  8. Microleakage Evaluation at Implant-Abutment Interface Using Radiotracer Technique

    PubMed Central

    Siadat, Hakimeh; Arshad, Mahnaz; Mahgoli, Hossein-Ali; Fallahi, Babak

    2016-01-01

    Objectives: Microbial leakage through the implant-abutment (I-A) interface results in bacterial colonization in two-piece implants. The aim of this study was to compare microleakage rates in three types of Replace abutments namely Snappy, GoldAdapt, and customized ceramic using radiotracing. Materials and Methods: Three groups, one for each abutment type, of five implants and one positive and one negative control were considered (a total of 17 regular body implants). A torque of 35 N/cm was applied to the abutments. The samples were immersed in thallium 201 radioisotope solution for 24 hours to let the radiotracers leak through the I-A interface. Then, gamma photons received from the radiotracers were counted using a gamma counter device. In the next phase, cyclic fatigue loading process was applied followed by the same steps of immersion in the radioactive solution and photon counting. Results: Rate of microleakage significantly increased (P≤0.05) in all three types of abutments (i.e. Snappy, GoldAdapt, and ceramic) after cyclic loading. No statistically significant differences were observed between abutment types after cyclic loading. Conclusions: Microleakage significantly increases after cyclic loading in all three Replace abutments (GoldAdapt, Snappy, ceramic). Lowest microleakage before and after cyclic loading was observed in GoldAdapt followed by Snappy and ceramic. PMID:28392814

  9. Reducing the Teen Death Rate. KIDS COUNT Indicator Brief

    ERIC Educational Resources Information Center

    Shore, Rima; Shore, Barbara

    2009-01-01

    Life continues to hold considerable risk for adolescents in the United States. In 2006, the teen death rate stood at 64 deaths per 100,000 teens (13,739 teens) (KIDS COUNT Data Center, 2009). Although it has declined by 4 percent since 2000, the rate of teen death in this country remains substantially higher than in many peer nations, based…

  10. CASA-Mot technology: how results are affected by the frame rate and counting chamber.

    PubMed

    Bompart, Daznia; García-Molina, Almudena; Valverde, Anthony; Caldeira, Carina; Yániz, Jesús; Núñez de Murga, Manuel; Soler, Carles

    2018-04-04

    For over 30 years, CASA-Mot technology has been used for kinematic analysis of sperm motility in different mammalian species, but insufficient attention has been paid to the technical limitations of commercial computer-aided sperm analysis (CASA) systems. Counting chamber type and frame rate are two of the most important aspects to be taken into account. Counting chambers can be disposable or reusable, with different depths. In human semen analysis, reusable chambers with a depth of 10µm are the most frequently used, whereas for most farm animal species it is more common to use disposable chambers with a depth of 20µm . The frame rate was previously limited by the hardware, although changes in the number of images collected could lead to significant variations in some kinematic parameters, mainly in curvilinear velocity (VCL). A frame rate of 60 frames s-1 is widely considered to be the minimum necessary for satisfactory results. However, the frame rate is species specific and must be defined in each experimental condition. In conclusion, we show that the optimal combination of frame rate and counting chamber type and depth should be defined for each species and experimental condition in order to obtain reliable results.

  11. X-Ray Observations of High-Energy Pulsars: PSR B1951+32 and Geminga

    NASA Astrophysics Data System (ADS)

    Ho, Cheng

    Observations at frequencies across a wide range of electromagnetic spectra are key to the understanding of the origin and mechanisms of high-energy emissions from pulsars. We propose to observe the high-energy pulsars PSR B1951+32 and Geminga with XTE. These two sources emit X-rays at low enough count rate that we can acquire high resolution timing and spectral data, allowing us to perform detailed analysis on the ground. Staring integration of 10 ksec for each source is requested. Data obtained in these observations, together with those from ROSAT, GRO and a planned project for optical counterpart study at Los Alamos, will provide crucial information to advance high-energy pulsar research.

  12. Risk assessment of false-positive quantitative real-time PCR results in food, due to detection of DNA originating from dead cells.

    PubMed

    Wolffs, Petra; Norling, Börje; Rådström, Peter

    2005-03-01

    Real-time PCR technology is increasingly used for detection and quantification of pathogens in food samples. A main disadvantage of nucleic acid detection is the inability to distinguish between signals originating from viable cells and DNA released from dead cells. In order to gain knowledge concerning risks of false-positive results due to detection of DNA originating from dead cells, quantitative PCR (qPCR) was used to investigate the degradation kinetics of free DNA in four types of meat samples. Results showed that the fastest degradation rate was observed (1 log unit per 0.5 h) in chicken homogenate, whereas the slowest rate was observed in pork rinse (1 log unit per 120.5 h). Overall results indicated that degradation occurred faster in chicken samples than in pork samples and faster at higher temperatures. Based on these results, it was concluded that, especially in pork samples, there is a risk of false-positive PCR results. This was confirmed in a quantitative study on cell death and signal persistence over a period of 28 days, employing three different methods, i.e. viable counts, direct qPCR, and finally floatation, a recently developed discontinuous density centrifugation method, followed by qPCR. Results showed that direct qPCR resulted in an overestimation of up to 10 times of the amount of cells in the samples compared to viable counts, due to detection of DNA from dead cells. However, after using floatation prior to qPCR, results resembled the viable count data. This indicates that by using of floatation as a sample treatment step prior to qPCR, the risk of false-positive PCR results due to detection of dead cells, can be minimized.

  13. Hospital Use of Observation Stays: Cross-sectional Study of the Impact on Readmission Rates.

    PubMed

    Venkatesh, Arjun K; Wang, Changqin; Ross, Joseph S; Altaf, Faseeha K; Suter, Lisa G; Vellanky, Smitha; Grady, Jacqueline N; Bernheim, Susannah M

    2016-12-01

    The Centers for Medicare and Medicaid Services publicly reports hospital risk-standardized readmission rates (RSRRs) as a measure of quality and performance; mischaracterizations may occur because observation stays are not captured by current measures. To describe variation in hospital use of observation stays, the relationship between hospitals observation stay use and RSRRs. Cross-sectional analysis of Medicare fee-for-service beneficiaries discharged after acute myocardial infarction (AMI), heart failure, or pneumonia between July 2011 and June 2012. We calculated 3 hospital-specific 30-day outcomes: (1) observation rate, the proportion of all discharges followed by an observation stay without a readmission; (2) observation proportion, the proportion of observation stays among all patients with an observation stay or readmission; and (3) RSRR. For all 3 conditions, hospitals' observation rates were <2.5% and observation proportions were <12%, although there was variation across hospitals, including 28% of hospital with no observation stay use for AMI, 31% for heart failure, and 43% for pneumonia. There were statistically significant, but minimal, correlations between hospital observation rates and RSRRs: AMI (r=-0.02), heart failure (r=-0.11), and pneumonia (r=-0.02) (P<0.001). There were modest inverse correlations between hospital observation proportion and RSRR: AMI (r=-0.34), heart failure (r=-0.26), and pneumonia (r=-0.21) (P<0.001). If observation stays were included in readmission measures, <4% of top performing hospitals would be recategorized as having average performance. Hospitals' observation stay use in the postdischarge period is low, but varies widely. Despite modest correlation between the observation proportion and RSRR, counting observation stays in readmission measures would minimally impact public reporting of performance.

  14. A study of starting time in great hard X-ray flares

    NASA Technical Reports Server (NTRS)

    Klein, K. L.; Pick, M.; Magun, A.

    1986-01-01

    An analysis of the starting time in ten great hard X-ray bursts observed with the X-Ray Burst Spectrometer (HXRBS) is presented. It is shown that the impulsive phase of nine of them is composed of a preflash phase, during which the burst is observed up to an energy limit ranging from some tens of keV to 200 keV, followed ten to some tens of seconds afterwards by a flash phase, where the count rate rises simultaneously in all detector channels. For two events strong gamma-ray line emission is observed and is shown to start close to the onset of the flash phase.

  15. Note: Fully integrated active quenching circuit achieving 100 MHz count rate with custom technology single photon avalanche diodes.

    PubMed

    Acconcia, G; Labanca, I; Rech, I; Gulinatti, A; Ghioni, M

    2017-02-01

    The minimization of Single Photon Avalanche Diodes (SPADs) dead time is a key factor to speed up photon counting and timing measurements. We present a fully integrated Active Quenching Circuit (AQC) able to provide a count rate as high as 100 MHz with custom technology SPAD detectors. The AQC can also operate the new red enhanced SPAD and provide the timing information with a timing jitter Full Width at Half Maximum (FWHM) as low as 160 ps.

  16. EM Adaptive LASSO—A Multilocus Modeling Strategy for Detecting SNPs Associated with Zero-inflated Count Phenotypes

    PubMed Central

    Mallick, Himel; Tiwari, Hemant K.

    2016-01-01

    Count data are increasingly ubiquitous in genetic association studies, where it is possible to observe excess zero counts as compared to what is expected based on standard assumptions. For instance, in rheumatology, data are usually collected in multiple joints within a person or multiple sub-regions of a joint, and it is not uncommon that the phenotypes contain enormous number of zeroes due to the presence of excessive zero counts in majority of patients. Most existing statistical methods assume that the count phenotypes follow one of these four distributions with appropriate dispersion-handling mechanisms: Poisson, Zero-inflated Poisson (ZIP), Negative Binomial, and Zero-inflated Negative Binomial (ZINB). However, little is known about their implications in genetic association studies. Also, there is a relative paucity of literature on their usefulness with respect to model misspecification and variable selection. In this article, we have investigated the performance of several state-of-the-art approaches for handling zero-inflated count data along with a novel penalized regression approach with an adaptive LASSO penalty, by simulating data under a variety of disease models and linkage disequilibrium patterns. By taking into account data-adaptive weights in the estimation procedure, the proposed method provides greater flexibility in multi-SNP modeling of zero-inflated count phenotypes. A fast coordinate descent algorithm nested within an EM (expectation-maximization) algorithm is implemented for estimating the model parameters and conducting variable selection simultaneously. Results show that the proposed method has optimal performance in the presence of multicollinearity, as measured by both prediction accuracy and empirical power, which is especially apparent as the sample size increases. Moreover, the Type I error rates become more or less uncontrollable for the competing methods when a model is misspecified, a phenomenon routinely encountered in practice. PMID:27066062

  17. EM Adaptive LASSO-A Multilocus Modeling Strategy for Detecting SNPs Associated with Zero-inflated Count Phenotypes.

    PubMed

    Mallick, Himel; Tiwari, Hemant K

    2016-01-01

    Count data are increasingly ubiquitous in genetic association studies, where it is possible to observe excess zero counts as compared to what is expected based on standard assumptions. For instance, in rheumatology, data are usually collected in multiple joints within a person or multiple sub-regions of a joint, and it is not uncommon that the phenotypes contain enormous number of zeroes due to the presence of excessive zero counts in majority of patients. Most existing statistical methods assume that the count phenotypes follow one of these four distributions with appropriate dispersion-handling mechanisms: Poisson, Zero-inflated Poisson (ZIP), Negative Binomial, and Zero-inflated Negative Binomial (ZINB). However, little is known about their implications in genetic association studies. Also, there is a relative paucity of literature on their usefulness with respect to model misspecification and variable selection. In this article, we have investigated the performance of several state-of-the-art approaches for handling zero-inflated count data along with a novel penalized regression approach with an adaptive LASSO penalty, by simulating data under a variety of disease models and linkage disequilibrium patterns. By taking into account data-adaptive weights in the estimation procedure, the proposed method provides greater flexibility in multi-SNP modeling of zero-inflated count phenotypes. A fast coordinate descent algorithm nested within an EM (expectation-maximization) algorithm is implemented for estimating the model parameters and conducting variable selection simultaneously. Results show that the proposed method has optimal performance in the presence of multicollinearity, as measured by both prediction accuracy and empirical power, which is especially apparent as the sample size increases. Moreover, the Type I error rates become more or less uncontrollable for the competing methods when a model is misspecified, a phenomenon routinely encountered in practice.

  18. Trends in prevalence of allergic rhinitis and correlation with pollen counts in Switzerland

    NASA Astrophysics Data System (ADS)

    Frei, Thomas; Gassner, Ewald

    2008-11-01

    In recent decades, a large number of epidemiological studies investigating the change of prevalence of hay fever showed an increase in the occurrence of this disease. However, other studies carried out in the 1990s yielded contradictory results. Many environmental factors have been hypothesized to contribute to the increasing hay fever rate, including both indoor and ambient air pollution, reduced exposure to microbial stimulation and changes in diets. However, the observed increase has not convincingly been explained by any of these factors and there is limited evidence of changes in exposure to these risk factors over time. Additionally, recent studies show that no further increase in asthma, hay fever and atopic sensitisation in adolescents and adults has been observed during the 1990s and the beginning of the new century. As the pattern of pollen counts has changed over the years, partly due to the global warming but also as a consequence of a change in the use of land, the changing prevalence of hay fever might partly be driven by this different pollen exposure. Epidemiological data for hay fever in Switzerland are available from 1926 until 2000 (with large gaps between 1926 and 1958 and 1958 to 1986) whereas pollen data are available from 1969 until the present. This allows an investigation as to whether these data are correlated provided the same time spans are compared. It would also be feasible to correlate the pollen data with meteorological data which, however, is not the subject of our investigation. Our study focuses on analyzing time series of pollen counts and of pollen season lengths in order to identify their trends, and to ascertain whether there is a relationship between these trends and the changes in the hay fever prevalence. It is shown in this paper that the pollen exposure has been decreasing in Basel since the beginning of the 1990s whereas the rate of the hay fever prevalence in Switzerland remained approximately unchanged in this period but with a slight tendency to decrease. In Locarno, most of the pollen species also show a decreasing trend, while in Zurich, the development is somewhat different as the pollen counts of most of the pollen types have been increasing. It is interesting, however, that some of the pollen counts of this station (grass, stinging nettle, mugwort and ragweed) have been decreasing in the period 1982-2007.

  19. Neutron counting with cameras

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Esch, Patrick; Crisanti, Marta; Mutti, Paolo

    2015-07-01

    A research project is presented in which we aim at counting individual neutrons with CCD-like cameras. We explore theoretically a technique that allows us to use imaging detectors as counting detectors at lower counting rates, and transits smoothly to continuous imaging at higher counting rates. As such, the hope is to combine the good background rejection properties of standard neutron counting detectors with the absence of dead time of integrating neutron imaging cameras as well as their very good spatial resolution. Compared to Xray detection, the essence of thermal neutron detection is the nuclear conversion reaction. The released energies involvedmore » are of the order of a few MeV, while X-ray detection releases energies of the order of the photon energy, which is in the 10 KeV range. Thanks to advances in camera technology which have resulted in increased quantum efficiency, lower noise, as well as increased frame rate up to 100 fps for CMOS-type cameras, this more than 100-fold higher available detection energy implies that the individual neutron detection light signal can be significantly above the noise level, as such allowing for discrimination and individual counting, which is hard to achieve with X-rays. The time scale of CMOS-type cameras doesn't allow one to consider time-of-flight measurements, but kinetic experiments in the 10 ms range are possible. The theory is next confronted to the first experimental results. (authors)« less

  20. Dead-time correction for high-throughput fluorescence lifetime imaging microscopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Enderlein, Joerg; Ruhlandt, Daja; Chithik, Anna; Ebrecht, René; Wouters, Fred S.; Gregor, Ingo

    2016-02-01

    Fluorescence lifetime microscopy has become an important method of bioimaging, allowing not only to record intensity and spectral, but also lifetime information across an image. One of the most widely used methods of FLIM is based on Time-Correlated Single Photon Counting (TCSPC). In TCSPC, one determines this curve by exciting molecules with a periodic train of short laser pulses, and then measuring the time delay between the first recorded fluorescence photon after each exciting laser pulse. An important technical detail of TCSPC measurements is the fact that the delay times between excitation laser pulses and resulting fluorescence photons are always measured between a laser pulse and the first fluorescence photon which is detected after that pulse. At high count rates, this leads to so-called pile-up: ``early'' photons eclipse long-delay photons, resulting in heavily skewed TCSPC histograms. To avoid pile-up, a rule of thumb is to perform TCSPC measurements at photon count rates which are at least hundred times smaller than the laser-pulse excitation rate. The downside of this approach is that the fluorescence-photon count-rate is restricted to a value below one hundredth of the laser-pulse excitation-rate, reducing the overall speed with which a fluorescence signal can be measured. We present a new data evaluation method which provides pile-up corrected fluorescence decay estimates from TCSPC measurements at high count rates, and we demonstrate our method on FLIM of fluorescently labeled cells.

  1. Development of an Automatic Echo-counting Program for HROFFT Spectrograms

    NASA Astrophysics Data System (ADS)

    Noguchi, Kazuya; Yamamoto, Masa-Yuki

    2008-06-01

    Radio meteor observations by Ham-band beacon or FM radio broadcasts using “Ham-band Radio meteor Observation Fast Fourier Transform” (HROFFT) an automatic operating software have been performed widely in recent days. Previously, counting of meteor echoes on the spectrograms of radio meteor observation was performed manually by observers. In the present paper, we introduce an automatic meteor echo counting software application. Although output images of the HROFFT contain both the features of meteor echoes and those of various types of noises, a newly developed image processing technique has been applied, resulting in software that enables a useful auto-counting tool. There exists a slight error in the processing on spectrograms when the observation site is affected by many disturbing noises. Nevertheless, comparison between software and manual counting revealed an agreement of almost 90%. Therefore, we can easily obtain a dataset of detection time, duration time, signal strength, and Doppler shift of each meteor echo from the HROFFT spectrograms. Using this software, statistical analyses of meteor activities is based on the results obtained at many Ham-band Radio meteor Observation (HRO) sites throughout the world, resulting in a very useful “standard” for monitoring meteor stream activities in real time.

  2. 200-300 N. Stetson, January 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates throughout the grading ranged from 4,500 cpm to 8,000 cpm. No count rates were found at any time that exceeded the threshold limits of 17,246 cpm and 18,098 cpm.

  3. 0 - 36 W. Illinois St., January 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,600 cpm to 3,700 cpm.No count rates were found at any time that exceeded the threshold limits of 6,738 cpm and 7,029 cpm.

  4. 400-449 N. State St, March 2017, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation. The count rates in the excavation ranged from 1,600 cpm to 4,300 cpm. No count rates were found at any time that exceeded the threshold limits of 6,338 cpm and 7,038 cpm.

  5. Database crime to crime match rate calculation.

    PubMed

    Buckleton, John; Bright, Jo-Anne; Walsh, Simon J

    2009-06-01

    Guidance exists on how to count matches between samples in a crime sample database but we are unable to locate a definition of how to estimate a match rate. We propose a method that does not proceed from the match counting definition but which has a strong logic.

  6. Performance of large area x-ray proportional counters in a balloon experiment

    NASA Astrophysics Data System (ADS)

    Roy, J.; Agrawal, P. C.; Dedhia, D. K.; Manchanda, R. K.; Shah, P. B.; Chitnis, V. R.; Gujar, V. M.; Parmar, J. V.; Pawar, D. M.; Kurhade, V. B.

    2016-10-01

    ASTROSAT is India's first satellite fully devoted to astronomical observations covering a wide spectral band from optical to hard X-rays by a complement of 4 co-aligned instruments and a Scanning Sky X-ray Monitor. One of the instruments is Large Area X-ray Proportional Counter with 3 identical detectors. In order to assess the performance of this instrument, a balloon experiment with two prototype Large Area X-ray Proportional Counters (LAXPC) was carried out on 2008 April 14. The design of these LAXPCs was similar to those on the ASTROSAT except that their field of view (FOV) was 3 ∘ × 3 ∘ versus FOV of 1 ∘ × 1 ∘ for the LAXPCs on the ASTROSAT. The LAXPCs are aimed at the timing and spectral studies of X-ray sources in 3-80 keV region. In the balloon experiment, the LAXPC, associated electronics and support systems were mounted on an oriented platform which could be pre-programmed to track any source in the sky. A brief description of the LAXPC design, laboratory tests, calibration and the detector characteristics is presented here. The details of the experiment and background counting rates of the 2 LAXPCs at the float altitude of about 41 km are presented in different energy bands. The bright black hole X-ray binary Cygnus X-1 (Cyg X-1) was observed in the experiment for ˜ 3 hours. Details of Cyg X-1 observations, count rates measured from it in different energy intervals and the intensity variations of Cyg X-1 detected during the observations are presented and briefly discussed.

  7. 45 CFR 261.34 - Are there any limitations in counting job search and job readiness assistance toward the...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 2 2011-10-01 2011-10-01 false Are there any limitations in counting job search and job readiness assistance toward the participation rates? 261.34 Section 261.34 Public Welfare... Work Activities and How Do They Count? § 261.34 Are there any limitations in counting job search and...

  8. 45 CFR 261.34 - Are there any limitations in counting job search and job readiness assistance toward the...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 2 2013-10-01 2012-10-01 true Are there any limitations in counting job search and job readiness assistance toward the participation rates? 261.34 Section 261.34 Public Welfare... Work Activities and How Do They Count? § 261.34 Are there any limitations in counting job search and...

  9. 45 CFR 261.34 - Are there any limitations in counting job search and job readiness assistance toward the...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 2 2010-10-01 2010-10-01 false Are there any limitations in counting job search and job readiness assistance toward the participation rates? 261.34 Section 261.34 Public Welfare... Work Activities and How Do They Count? § 261.34 Are there any limitations in counting job search and...

  10. 45 CFR 261.34 - Are there any limitations in counting job search and job readiness assistance toward the...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 45 Public Welfare 2 2012-10-01 2012-10-01 false Are there any limitations in counting job search and job readiness assistance toward the participation rates? 261.34 Section 261.34 Public Welfare... Work Activities and How Do They Count? § 261.34 Are there any limitations in counting job search and...

  11. 45 CFR 261.34 - Are there any limitations in counting job search and job readiness assistance toward the...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 2 2014-10-01 2012-10-01 true Are there any limitations in counting job search and job readiness assistance toward the participation rates? 261.34 Section 261.34 Public Welfare... Work Activities and How Do They Count? § 261.34 Are there any limitations in counting job search and...

  12. Bunch mode specific rate corrections for PILATUS3 detectors

    DOE PAGES

    Trueb, P.; Dejoie, C.; Kobas, M.; ...

    2015-04-09

    PILATUS X-ray detectors are in operation at many synchrotron beamlines around the world. This article reports on the characterization of the new PILATUS3 detector generation at high count rates. As for all counting detectors, the measured intensities have to be corrected for the dead-time of the counting mechanism at high photon fluxes. The large number of different bunch modes at these synchrotrons as well as the wide range of detector settings presents a challenge for providing accurate corrections. To avoid the intricate measurement of the count rate behaviour for every bunch mode, a Monte Carlo simulation of the counting mechanismmore » has been implemented, which is able to predict the corrections for arbitrary bunch modes and a wide range of detector settings. This article compares the simulated results with experimental data acquired at different synchrotrons. It is found that the usage of bunch mode specific corrections based on this simulation improves the accuracy of the measured intensities by up to 40% for high photon rates and highly structured bunch modes. For less structured bunch modes, the instant retrigger technology of PILATUS3 detectors substantially reduces the dependency of the rate correction on the bunch mode. The acquired data also demonstrate that the instant retrigger technology allows for data acquisition up to 15 million photons per second per pixel.« less

  13. Development of an ideal observer that incorporates nuisance parameters and processes list-mode data

    DOE PAGES

    MacGahan, Christopher Jonathan; Kupinski, Matthew Alan; Hilton, Nathan R.; ...

    2016-02-01

    Observer models were developed to process data in list-mode format in order to perform binary discrimination tasks for use in an arms-control-treaty context. Data used in this study was generated using GEANT4 Monte Carlo simulations for photons using custom models of plutonium inspection objects and a radiation imaging system. We evaluated observer model performance and then presented using the area under the receiver operating characteristic curve. Lastly, we studied the ideal observer under both signal-known-exactly conditions and in the presence of unknowns such as object orientation and absolute count-rate variability; when these additional sources of randomness were present, their incorporationmore » into the observer yielded superior performance.« less

  14. The prevalence of abnormal leukocyte count, and its predisposing factors, in patients with sickle cell disease in Saudi Arabia.

    PubMed

    Ahmed, Anwar E; Ali, Yosra Z; Al-Suliman, Ahmad M; Albagshi, Jafar M; Al Salamah, Majid; Elsayid, Mohieldin; Alanazi, Wala R; Ahmed, Rayan A; McClish, Donna K; Al-Jahdali, Hamdan

    2017-01-01

    High white blood cell (WBC) count is an indicator of sickle cell disease (SCD) severity, however, there are limited studies on WBC counts in Saudi Arabian patients with SCD. The aim of this study was to estimate the prevalence of abnormal leukocyte count (either low or high) and identify factors associated with high WBC counts in a sample of Saudi patients with SCD. A cross-sectional and retrospective chart review study was carried out on 290 SCD patients who were routinely treated at King Fahad Hospital in Hofuf, Saudi Arabia. An interview was conducted to assess clinical presentations, and we reviewed patient charts to collect data on blood test parameters for the previous 6 months. Almost half (131 [45.2%]) of the sample had abnormal leukocyte counts: low WBC counts 15 (5.2%) and high 116 (40%). High WBC counts were associated with shortness of breath ( P =0.022), tiredness ( P =0.039), swelling in hands/feet ( P =0.020), and back pain ( P =0.007). The mean hemoglobin was higher in patients with normal WBC counts ( P =0.024), while the mean hemoglobin S was high in patients with high WBC counts ( P =0.003). After adjustment for potential confounders, predictors of high WBC counts were male gender (adjusted odds ratio [aOR]=3.63) and patients with cough (aOR=2.18), low hemoglobin (aOR=0.76), and low heart rate (aOR=0.97). Abnormal leukocyte count was common: approximately five in ten Saudi SCD patients assessed in this sample. Male gender, cough, low hemoglobin, and low heart rate were associated with high WBC count. Strategies targeting high WBC count could prevent disease complication and thus could be beneficial for SCD patients.

  15. On the decades-long stability of the interstellar wind through the solar system

    NASA Astrophysics Data System (ADS)

    Lallement, R.; Bertaux, J. L.

    2014-05-01

    We have revisited the series of observations recently used to infer a temporal variation in the interstellar helium flow over the past forty years. Concerning the recent IBEX-Lo direct detection of helium neutrals, there are two types of precise and unambiguous measurements that do not rely on the exact response of the instrument: the count rate maxima as a function of the spin angle, which determines the ecliptic latitude of the flow, and the count rate maxima as a function of IBEX longitude, which determines a tight relationship between the ecliptic longitude of the flow and its velocity far from the Sun. These measurements provide parameters (and couples of parameters in the second case) that are remarkably similar to the canonical, old values. In contrast, the preferred choice of a lower velocity and higher longitude reported before from IBEX data is only based on the count rate variation (at each spin phase maximum) as a function of the satellite longitude, when drifting across the region of high fluxes. We have examined the consequences of dead-time counting effects and conclude that including them at a realistic level is sufficient to reconcile the data with the old parameters, calling for further investigations. We discuss the analyses of the STEREO pickup ion data and argue that the statistical method that has been preferred to infer the neutral flow longitude (instead of the more direct method based on the pickup ion maximum flux directions) is not appropriate. Moreover, transport effects may have been significant at the very weak solar activity level of 2007-2009, in which case the longitudes of the pickup ion maxima are only upper limits on the flow longitude. Finally, we found that using some flow longitude determinations based on UV glow data is not adequate. Based on this global study, and at variance with recent conclusions, we find no evidence for a temporal variability of the interstellar helium flow. This has implications for inner and outer heliosphere studies.

  16. Acute lymphoblastic leukemia in children and adolescents: prognostic factors and analysis of survival

    PubMed Central

    Lustosa de Sousa, Daniel Willian; de Almeida Ferreira, Francisco Valdeci; Cavalcante Félix, Francisco Helder; de Oliveira Lopes, Marcos Vinicios

    2015-01-01

    Objective To describe the clinical and laboratory features of children and adolescents with acute lymphoblastic leukemia treated at three referral centers in Ceará and evaluate prognostic factors for survival, including age, gender, presenting white blood cell count, immunophenotype, DNA index and early response to treatment. Methods Seventy-six under 19-year-old patients with newly diagnosed acute lymphoblastic leukemia treated with the Grupo Brasileiro de Tratamento de Leucemia da Infância – acute lymphoblastic leukemia-93 and -99 protocols between September 2007 and December 2009 were analyzed. The diagnosis was based on cytological, immunophenotypic and cytogenetic criteria. Associations between variables, prognostic factors and response to treatment were analyzed using the chi-square test and Fisher's exact test. Overall and event-free survival were estimated by Kaplan–Meier analysis and compared using the log-rank test. A Cox proportional hazards model was used to identify independent prognostic factors. Results The average age at diagnosis was 6.3 ± 0.5 years and males were predominant (65%). The most frequently observed clinical features were hepatomegaly, splenomegaly and lymphadenopathy. Central nervous system involvement and mediastinal enlargement occurred in 6.6% and 11.8%, respectively. B-acute lymphoblastic leukemia was more common (89.5%) than T-acute lymphoblastic leukemia. A DNA index >1.16 was found in 19% of patients and was associated with favorable prognosis. On Day 8 of induction therapy, 95% of the patients had lymphoblast counts <1000/μL and white blood cell counts <5.0 × 109/L. The remission induction rate was 95%, the induction mortality rate was 2.6% and overall survival was 72%. Conclusion The prognostic factors identified are compatible with the literature. The 5-year overall and event-free survival rates were lower than those reported for developed countries. As shown by the multivariate analysis, age and baseline white blood cell count were independent prognostic factors. PMID:26190424

  17. Effect of Social Comparison Feedback on Laboratory Test Ordering for Hospitalized Patients: A Randomized Controlled Trial.

    PubMed

    Ryskina, Kira; Jessica Dine, C; Gitelman, Yevgeniy; Leri, Damien; Patel, Mitesh; Kurtzman, Gregory; Lin, Lisa Y; Epstein, Andrew J

    2018-05-22

    Social comparison feedback is an increasingly popular strategy that uses performance report cards to modify physician behavior. Our objective was to test the effect of such feedback on the ordering of routine laboratory tests for hospitalized patients, a practice considered overused. This was a single-blinded randomized controlled trial. Between January and June 2016, physicians on six general medicine teams at the Hospital of the University of Pennsylvania were cluster randomized with equal allocation to two arms: (1) those e-mailed a summary of their routine laboratory test ordering vs. the service average for the prior week, linked to a continuously updated personalized dashboard containing patient-level details, and snapshot of the dashboard and (2) those who did not receive the intervention. The primary outcome was the count of routine laboratory test orders placed by a physician per patient-day. We modeled the count of orders by each physician per patient-day after the intervention as a function of trial arm and the physician's order count before the intervention. The count outcome was modeled using negative binomial models with adjustment for clustering within teams. One hundred and fourteen interns and residents participated. We did not observe a statistically significant difference in adjusted reduction in routine laboratory ordering between the intervention and control physicians (physicians in the intervention group ordered 0.14 fewer tests per patient-day than physicians in the control group, 95% CI - 0.56 to 0.27, p = 0.50). Physicians whose absolute ordering rate deviated from the peer rate by more than 1.0 laboratory test per patient-day reduced their laboratory ordering by 0.80 orders per patient-day (95% CI - 1.58 to - 0.02, p = 0.04). Personalized social comparison feedback on routine laboratory ordering did not change targeted behavior among physicians, although there was a significant decrease in orders among participants who deviated more from the peer rate. Clinicaltrials.gov registration: #NCT02330289.

  18. Characteristics and Energy Dependence of Recurrent Galactic Cosmic-Ray Flux Depressions and of a Forbush Decrease with LISA Pathfinder

    NASA Astrophysics Data System (ADS)

    Armano, M.; Audley, H.; Baird, J.; Bassan, M.; Benella, S.; Binetruy, P.; Born, M.; Bortoluzzi, D.; Cavalleri, A.; Cesarini, A.; Cruise, A. M.; Danzmann, K.; de Deus Silva, M.; Diepholz, I.; Dixon, G.; Dolesi, R.; Fabi, M.; Ferraioli, L.; Ferroni, V.; Finetti, N.; Fitzsimons, E. D.; Freschi, M.; Gesa, L.; Gibert, F.; Giardini, D.; Giusteri, R.; Grimani, C.; Grzymisch, J.; Harrison, I.; Heinzel, G.; Hewitson, M.; Hollington, D.; Hoyland, D.; Hueller, M.; Inchauspé, H.; Jennrich, O.; Jetzer, P.; Karnesis, N.; Kaune, B.; Korsakova, N.; Killow, C. J.; Laurenza, M.; Lobo, J. A.; Lloro, I.; Liu, L.; López-Zaragoza, J. P.; Maarschalkerweerd, R.; Mance, D.; Martín, V.; Martin-Polo, L.; Martino, J.; Martin-Porqueras, F.; Mateos, I.; McNamara, P. W.; Mendes, J.; Mendes, L.; Nofrarias, M.; Paczkowski, S.; Perreur-Lloyd, M.; Petiteau, A.; Pivato, P.; Plagnol, E.; Ramos-Castro, J.; Reiche, J.; Robertson, D. I.; Rivas, F.; Russano, G.; Sabbatini, F.; Slutsky, J.; Sopuerta, C. F.; Sumner, T.; Telloni, D.; Texier, D.; Thorpe, J. I.; Vetrugno, D.; Vitale, S.; Wanner, G.; Ward, H.; Wass, P.; Weber, W. J.; Wissel, L.; Wittchen, A.; Zambotti, A.; Zenoni, C.; Zweifel, P.

    2018-02-01

    Galactic cosmic-ray (GCR) energy spectra observed in the inner heliosphere are modulated by the solar activity, the solar polarity and structures of solar and interplanetary origin. A high counting rate particle detector (PD) aboard LISA Pathfinder, meant for subsystems diagnostics, was devoted to the measurement of GCR and solar energetic particle integral fluxes above 70 MeV n‑1 up to 6500 counts s‑1. PD data were gathered with a sampling time of 15 s. Characteristics and energy dependence of GCR flux recurrent depressions and of a Forbush decrease dated 2016 August 2 are reported here. The capability of interplanetary missions, carrying PDs for instrument performance purposes, in monitoring the passage of interplanetary coronal mass ejections is also discussed.

  19. Analysis of overdispersed count data by mixtures of Poisson variables and Poisson processes.

    PubMed

    Hougaard, P; Lee, M L; Whitmore, G A

    1997-12-01

    Count data often show overdispersion compared to the Poisson distribution. Overdispersion is typically modeled by a random effect for the mean, based on the gamma distribution, leading to the negative binomial distribution for the count. This paper considers a larger family of mixture distributions, including the inverse Gaussian mixture distribution. It is demonstrated that it gives a significantly better fit for a data set on the frequency of epileptic seizures. The same approach can be used to generate counting processes from Poisson processes, where the rate or the time is random. A random rate corresponds to variation between patients, whereas a random time corresponds to variation within patients.

  20. Hantavirus pulmonary syndrome, United States, 1993-2009.

    PubMed

    MacNeil, Adam; Ksiazek, Thomas G; Rollin, Pierre E

    2011-07-01

    Hantavirus pulmonary syndrome (HPS) is a severe respiratory illness identified in 1993. Since its identification, the Centers for Disease Control and Prevention has obtained standardized information about and maintained a registry of all laboratory-confirmed HPS cases in the United States. During 1993-2009, a total of 510 HPS cases were identified. Case counts have varied from 11 to 48 per year (case-fatality rate 35%). However, there were no trends suggesting increasing or decreasing case counts or fatality rates. Although cases were reported in 30 states, most cases occurred in the western half of the country; annual case counts varied most in the southwestern United States. Increased hematocrits, leukocyte counts, and creatinine levels were more common in HPS case-patients who died. HPS is a severe disease with a high case-fatality rate, and cases continue to occur. The greatest potential for high annual HPS incidence exists in the southwestern United States.

  1. Variance in population firing rate as a measure of slow time-scale correlation

    PubMed Central

    Snyder, Adam C.; Morais, Michael J.; Smith, Matthew A.

    2013-01-01

    Correlated variability in the spiking responses of pairs of neurons, also known as spike count correlation, is a key indicator of functional connectivity and a critical factor in population coding. Underscoring the importance of correlation as a measure for cognitive neuroscience research is the observation that spike count correlations are not fixed, but are rather modulated by perceptual and cognitive context. Yet while this context fluctuates from moment to moment, correlation must be calculated over multiple trials. This property undermines its utility as a dependent measure for investigations of cognitive processes which fluctuate on a trial-to-trial basis, such as selective attention. A measure of functional connectivity that can be assayed on a moment-to-moment basis is needed to investigate the single-trial dynamics of populations of spiking neurons. Here, we introduce the measure of population variance in normalized firing rate for this goal. We show using mathematical analysis, computer simulations and in vivo data how population variance in normalized firing rate is inversely related to the latent correlation in the population, and how this measure can be used to reliably classify trials from different typical correlation conditions, even when firing rate is held constant. We discuss the potential advantages for using population variance in normalized firing rate as a dependent measure for both basic and applied neuroscience research. PMID:24367326

  2. Performance characteristics of high-conductivity channel electron multipliers. [as UV and x ray detector

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.; Bybee, R. L.

    1978-01-01

    The paper describes a new type of continuous channel multiplier (CEM) fabricated from a low-resistance glass to produce a high-conductivity channel section and thereby obtain a high count-rate capability. The flat-cone cathode configuration of the CEM is specifically designed for the detection of astigmatic exit images from grazing-incidence spectrometers at the optimum angle of illumination for high detection efficiencies at XUV wavelengths. Typical operating voltages are in the range of 2500-2900 V with stable counting plateau slopes in the range 3-6% per 100-V increment. The modal gain at 2800 V was typically in the range (50-80) million. The modal gain falls off at count rates in excess of about 20,000 per sec. The detection efficiency remains essentially constant to count rates in excess of 2 million per sec. Higher detection efficiencies (better than 20%) are obtained by coating the CEM with MgF2. In life tests of coated CEMs, no measurable change in detection efficiency was measured to a total accumulated signal of 2 times 10 to the 11th power counts.

  3. Key Facts about the Children: Florida Kids Count 1994. A Report on the Status of Florida's Children: Volume V.

    ERIC Educational Resources Information Center

    University of South Florida, Tampa. Florida Center for Children and Youth.

    This Kids Count report investigates statewide trends in the well-being of Florida's children. The statistical report is based on 19 indicators of child well being: (1) low birth weight infants; (2) infant mortality rate; (3) child death rate; (4) births to single teens; (5) juvenile violent crime arrest rate; (6) percent graduating from high…

  4. 1-99 W. Hubbard St, May 2018, Lindsay Light Radiological Survey

    EPA Pesticide Factsheets

    Radiological Survey of Right-of-Way Utility Excavation.The count rates in the excavation ranged from 2,100 cpm to 4,200 cpm.No count rates were found at any time that exceeded the instrument specific threshold limits of 7,366 and 6,415 cpm.

  5. Is Parenting Child's Play? Kids Count in Missouri Report on Adolescent Pregnancy.

    ERIC Educational Resources Information Center

    Citizens for Missouri's Children, St. Louis.

    This Kids Count report presents current information on adolescent pregnancy rates in Missouri. Part 1, "Overview of Adolescent Pregnancy in Missouri," discusses the changing pregnancy, abortion, and birth rates for 15- to 19-year-old adolescents, racial differences in pregnancy risk, regional differences suggesting a link between…

  6. Deep Galex Observations of the Coma Cluster: Source Catalog and Galaxy Counts

    NASA Technical Reports Server (NTRS)

    Hammer, D.; Hornschemeier, A. E.; Mobasher, B.; Miller, N.; Smith, R.; Arnouts, S.; Milliard, B.; Jenkins, L.

    2010-01-01

    We present a source catalog from deep 26 ks GALEX observations of the Coma cluster in the far-UV (FUV; 1530 Angstroms) and near-UV (NUV; 2310 Angstroms) wavebands. The observed field is centered 0.9 deg. (1.6 Mpc) south-west of the Coma core, and has full optical photometric coverage by SDSS and spectroscopic coverage to r-21. The catalog consists of 9700 galaxies with GALEX and SDSS photometry, including 242 spectroscopically-confirmed Coma member galaxies that range from giant spirals and elliptical galaxies to dwarf irregular and early-type galaxies. The full multi-wavelength catalog (cluster plus background galaxies) is 80% complete to NUV=23 and FUV=23.5, and has a limiting depth at NUV=24.5 and FUV=25.0 which corresponds to a star formation rate of 10(exp -3) solar mass yr(sup -1) at the distance of Coma. The GALEX images presented here are very deep and include detections of many resolved cluster members superposed on a dense field of unresolved background galaxies. This required a two-fold approach to generating a source catalog: we used a Bayesian deblending algorithm to measure faint and compact sources (using SDSS coordinates as a position prior), and used the GALEX pipeline catalog for bright and/or extended objects. We performed simulations to assess the importance of systematic effects (e.g. object blends, source confusion, Eddington Bias) that influence source detection and photometry when using both methods. The Bayesian deblending method roughly doubles the number of source detections and provides reliable photometry to a few magnitudes deeper than the GALEX pipeline catalog. This method is also free from source confusion over the UV magnitude range studied here: conversely, we estimate that the GALEX pipeline catalogs are confusion limited at NUV approximately 23 and FUV approximately 24. We have measured the total UV galaxy counts using our catalog and report a 50% excess of counts across FUV=22-23.5 and NUV=21.5-23 relative to previous GALEX measurements, which is not attributed to cluster member galaxies. Our galaxy counts are a better match to deeper UV counts measured with HST.

  7. Performance study of thin epitaxial silicon PIN detectors for thermal neutron measurements with reduced γ sensitivity

    NASA Astrophysics Data System (ADS)

    Singh, Arvind; Desai, Shraddha; Kumar, Arvind; Topkar, Anita

    2018-05-01

    A novel approach of using thin epitaxial silicon PIN detectors for thermal neutron measurements with reduced γ sensitivity has been presented. Monte Carlo simulations showed that there is a significant reduction in the gamma sensitivity for thin detectors with the thickness of 10- 25 μm compared to a detector of thickness of 300 μm. Epitaxial PIN silicon detectors with the thickness of 10 μm, 15 μm and 25 μm were fabricated using a custom process. The detectors exhibited low leakage currents of a few nano-amperes. The gamma sensitivity of the detectors was experimentally studied using a 33 μCi, 662 keV, 137Cs source. Considering the count rates, compared to a 300 μm thick detector, the gamma sensitivity of the 10 μm, 15 μm and 25 μm thick detectors was reduced by factors of 1874, 187 and 18 respectively. The detector performance for thermal neutrons was subsequently investigated with a thermal neutron beam using an enriched 10B film as a neutron converter layer. The thermal neutron spectra for all three detectors exhibited three distinct regions corresponding to the 4He and 7Li charge products released in the 10B-n reaction. With a 10B converter, the count rates were 1466 cps, 3170 cps and 2980 cps for the detectors of thicknesses of 10 μm, 25 μm and 300 μm respectively. The thermal neutron response of thin detectors with 10 μm and 25 μm thickness showed significant reduction in the gamma sensitivity compared to that observed for the 300 μm thick detector. Considering the total count rate obtained for thermal neutrons with a 10B converter film, the count rate without the converter layer were about 4%, 7% and 36% for detectors with thicknesses of 10 μm, 25 μm and 300 μm respectively. The detector with 10 μm thickness showed negligible gamma sensitivity of 4 cps, but higher electronic noise and reduced pulse heights. The detector with 25 μm thickness demonstrated the best performance with respect to electronic noise, thermal neutron response and gamma sensitivity.

  8. High Spatial Resolution Studies of Epithermal Neutron Emission from the Lunar Poles: Constraints on Hydrogen Mobility

    NASA Technical Reports Server (NTRS)

    Boynton, W. V.; Droege, G. F.; Mitrofanov, I. G.; McClanahan, T. P.; Sanin, A. B.; Litvak, M. L.; Schaffner, M.; Chin, G.; Evans, L. G.; Garvin, J. B.; hide

    2012-01-01

    The data from the collimated sensors of the LEND instrument are shown to be of exceptionally high quality. Counting uncertainties are about 0.3% relative and are shown to be the only significant source of random error, thus conclusions based on small differences in count rates are valid. By comparison with the topography of Shoemaker crater, the spatial resolution of the instrument is shown to be consistent with the design value of 5 km for the radius of the circle over which half the counts from the lunar surface would be determined. The observed epithermal-neutron suppression factor due to the hydrogen deposit in Shoemaker crater of 0.25 plus or minus 0.04 cps is consistent with the collimated field-of-view rate of 1.7 cps estimated by Mitrofanov et al. (2010a). The statistical significance of the neutron suppressed regions (NSRs) relative to the larger surrounding polar region is demonstrated, and it is shown that they are not closely related to the permanently shadowed regions. There is a significant increase in H content in the polar regions independent of the H content of the NSRs. The non-NSR H content increases directly with latitude, and the rate of increase is virtually identical at both poles. There is little or no increase with latitude outside the polar region. Various mechanisms to explain this steep increase in the non-NSR polar H with latitude are investigated, and it is suggested that thermal volatilization is responsible for the increase because it is minimized at the low surface temperatures close to the poles.

  9. CD4 decline is associated with increased risk of cardiovascular disease, cancer, and death in virally suppressed patients with HIV.

    PubMed

    Helleberg, Marie; Kronborg, Gitte; Larsen, Carsten S; Pedersen, Gitte; Pedersen, Court; Obel, Niels; Gerstoft, Jan

    2013-07-01

    The clinical implications of a considerable CD4 decline despite antiretroviral treatment and viral suppression are unknown. We aimed to test the hypothesis that a major CD4 decline could be a marker of cardiovascular disease or undiagnosed cancer. Patients with human immunodeficiency virus (HIV) were followed in the Danish nationwide, population-based cohort study in the period 1995-2010 with quarterly CD4 measurements. Associations between a CD4 decline of ≥30% and cardiovascular disease, cancer, and death were analyzed using Poisson regression with date of CD4 decline as a time-updated variable. We followed 2584 virally suppressed HIV patients for 13 369 person-years (PY; median observation time, 4.7 years). Fifty-six patients developed CD4 decline (incidence rate, 4.2/1000 PY [95% confidence interval {CI}, 3.2-5.4]). CD4 counts dropped from a median of 492 cells/µL to 240 cells/µL. CD8, CD3, and total lymphocyte counts dropped concomitantly. No HIV-related factors, apart from treatment with didanosine, were associated with CD4 decline. The risk of cardiovascular disease, cancer, and death increased markedly ≤6 months after CD4 decline (incidence rate ratio, 11.7 [95% CI, 3.6-37.4] and 13.7 [95% CI, 4.3-43.6], respectively, and mortality rate ratio 4.3 [95% CI, 1.1-17.6]). A major decline in CD4 count is associated with a marked increased risk of cardiovascular disease, cancer, and death among virally suppressed HIV patients.

  10. Monte Carlo simulation of the neutron monitor yield function

    NASA Astrophysics Data System (ADS)

    Mangeard, P.-S.; Ruffolo, D.; Sáiz, A.; Madlee, S.; Nutaro, T.

    2016-08-01

    Neutron monitors (NMs) are ground-based detectors that measure variations of the Galactic cosmic ray flux at GV range rigidities. Differences in configuration, electronics, surroundings, and location induce systematic effects on the calculation of the yield functions of NMs worldwide. Different estimates of NM yield functions can differ by a factor of 2 or more. In this work, we present new Monte Carlo simulations to calculate NM yield functions and perform an absolute (not relative) comparison with the count rate of the Princess Sirindhorn Neutron Monitor (PSNM) at Doi Inthanon, Thailand, both for the entire monitor and for individual counter tubes. We model the atmosphere using profiles from the Global Data Assimilation System database and the Naval Research Laboratory Mass Spectrometer, Incoherent Scatter Radar Extended model. Using FLUKA software and the detailed geometry of PSNM, we calculated the PSNM yield functions for protons and alpha particles. An agreement better than 9% was achieved between the PSNM observations and the simulated count rate during the solar minimum of December 2009. The systematic effect from the electronic dead time was studied as a function of primary cosmic ray rigidity at the top of the atmosphere up to 1 TV. We show that the effect is not negligible and can reach 35% at high rigidity for a dead time >1 ms. We analyzed the response function of each counter tube at PSNM using its actual dead time, and we provide normalization coefficients between count rates for various tube configurations in the standard NM64 design that are valid to within ˜1% for such stations worldwide.

  11. Spatial representation and cognitive modulation of response variability in the lateral intraparietal area priority map.

    PubMed

    Falkner, Annegret L; Goldberg, Michael E; Krishna, B Suresh

    2013-10-09

    The lateral intraparietal area (LIP) in the macaque contains a priority-based representation of the visual scene. We previously showed that the mean spike rate of LIP neurons is strongly influenced by spatially wide-ranging surround suppression in a manner that effectively sharpens the priority map. Reducing response variability can also improve the precision of LIP's priority map. We show that when a monkey plans a visually guided delayed saccade with an intervening distractor, variability (measured by the Fano factor) decreases both for neurons representing the saccade goal and for neurons representing the broad spatial surround. The reduction in Fano factor is maximal for neurons representing the saccade goal and steadily decreases for neurons representing more distant locations. LIP Fano factor changes are behaviorally significant: increasing expected reward leads to lower variability for the LIP representation of both the target and distractor locations, and trials with shorter latency saccades are associated with lower Fano factors in neurons representing the surround. Thus, the LIP Fano factor reflects both stimulus and behavioral engagement. Quantitative modeling shows that the interaction between mean spike count and target-receptive field (RF) distance in the surround during the predistractor epoch is multiplicative: the Fano factor increases more steeply with mean spike count further away from the RF. A negative-binomial model for LIP spike counts captures these findings quantitatively, suggests underlying mechanisms based on trial-by-trial variations in mean spike rate or burst-firing patterns, and potentially provides a principled framework to account simultaneously for the previously observed unsystematic relationships between spike rate and variability in different brain areas.

  12. Blocking Losses With a Photon Counter

    NASA Technical Reports Server (NTRS)

    Moision, Burce E.; Piazzolla, Sabino

    2012-01-01

    It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

  13. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hoerner, Matthew R., E-mail: mrh5038@ufl.edu; Stepusin, Elliott J.; Hyer, Daniel E.

    Purpose: Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator,more » which has a higher sensitivity to scatter x-rays. Methods: The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm{sup 3} Radcal{sup ®} thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm{sup 3} calibrated ionization chamber to measure the reference air kerma. Results: Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. Conclusions: The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.« less

  14. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.

    PubMed

    Hoerner, Matthew R; Stepusin, Elliott J; Hyer, Daniel E; Hintenlang, David E

    2015-03-01

    Kilovoltage (kV) x-rays pose a significant challenge for radiation dosimetry. In the kV energy range, even small differences in material composition can result in significant variations in the absorbed energy between soft tissue and the detector. In addition, the use of electronic systems in light detection has demonstrated measurement losses at high photon fluence rates incident to the detector. This study investigated the feasibility of using a novel dual scintillator detector and whether its response to changes in beam energy from scatter and hardening is readily quantified. The detector incorporates a tissue-equivalent plastic scintillator and a gadolinium oxysulfide scintillator, which has a higher sensitivity to scatter x-rays. The detector was constructed by coupling two scintillators: (1) small cylindrical plastic scintillator, 500 μm in diameter and 2 mm in length, and (2) 100 micron sheet of gadolinium oxysulfide 500 μm in diameter, each to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube. Count rate linearity data were obtained from a wide range of exposure rates delivered from a radiological x-ray tube by adjusting the tube current. The data were fitted to a nonparalyzable dead time model to characterize the time response. The true counting rate was related to the reference free air dose air rate measured with a 0.6 cm(3) Radcal(®) thimble chamber as described in AAPM Report No. 111. Secondary electron and photon spectra were evaluated using Monte Carlo techniques to analyze ionization quenching and photon energy-absorption characteristics from free-in-air and in phantom measurements. The depth/energy dependence of the detector was characterized using a computed tomography dose index QA phantom consisting of nested adult head and body segments. The phantom provided up to 32 cm of acrylic with a compatible 0.6 cm(3) calibrated ionization chamber to measure the reference air kerma. Each detector exhibited counting losses of 5% when irradiated at a dose rate of 26.3 mGy/s (Gadolinium) and 324.3 mGy/s (plastic). The dead time of the gadolinium oxysulfide detector was determined to be 48 ns, while the dead time of the plastic scintillating detector was unable to accurately be calculated due to poor counting statistics from low detected count rates. Noticeable depth/energy dependence was observed for the plastic scintillator for depths greater than 16 cm of acrylic that was not present for measurements using the gadolinium oxysulfide scintillator, leading us to believe that quenching may play a larger role in the depth dependence of the plastic scintillator than the incident x-ray energy spectrum. When properly corrected for dead time effects, the energy response of the gadolinium oxysulfide scintillator is consistent with the plastic scintillator. Using the integrated dual detector method was superior to each detector individually as the depth-dependent measure of dose was correctable to less than 8% between 100 and 135 kV. The dual scintillator fiber-optic detector accommodates a methodology for energy dependent corrections of the plastic scintillator, improving the overall accuracy of the dosimeter across the range of diagnostic energies.

  15. Changes in Sensitization Rate to Weed Allergens in Children with Increased Weeds Pollen Counts in Seoul Metropolitan Area

    PubMed Central

    Kim, Joo-Hwa; Lee, Ha-Baik; Kim, Seong-Won; Kang, Im-Joo; Kook, Myung-Hee; Kim, Bong-Seong; Park, Kang-Seo; Baek, Hey-Sung; Kim, Kyu-Rang; Choi, Young-Jean

    2012-01-01

    The prevalence of allergic diseases in children has increased for several decades. We evaluated the correlation between pollen count of weeds and their sensitization rate in Seoul, 1997-2009. Airborne particles carrying allergens were collected daily from 3 stations around Seoul. Skin prick tests to pollen were performed on children with allergic diseases. Ragweed pollen gradually increased between 1999 and 2005, decreased after 2005 and plateaued until 2009 (peak counts, 67 in 2003, 145 in 2005 and 83 grains/m3/day in 2007). Japanese hop pollen increased between 2002 and 2009 (peak counts, 212 in 2006 and 492 grains/m3/day in 2009). Sensitization rates to weed pollen, especially ragweed and Japanese hop in children with allergic diseases, increased annually (ragweed, 2.2% in 2000 and 2.8% in 2002; Japanese hop, 1.4% in 2000 and 1.9% in 2002). The age for sensitization to pollen gradually became younger since 2000 (4 to 6 yr of age, 3.5% in 1997 and 6.2% in 2009; 7 to 9 yr of age, 4.2% in 1997 and 6.4% in 2009). In conclusion, sensitization rates for weed pollens increase in Korean children given increasing pollen counts of ragweed and Japanese hop. PMID:22468096

  16. Changes in sensitization rate to weed allergens in children with increased weeds pollen counts in Seoul metropolitan area.

    PubMed

    Kim, Joo-Hwa; Oh, Jae-Won; Lee, Ha-Baik; Kim, Seong-Won; Kang, Im-Joo; Kook, Myung-Hee; Kim, Bong-Seong; Park, Kang-Seo; Baek, Hey-Sung; Kim, Kyu-Rang; Choi, Young-Jean

    2012-04-01

    The prevalence of allergic diseases in children has increased for several decades. We evaluated the correlation between pollen count of weeds and their sensitization rate in Seoul, 1997-2009. Airborne particles carrying allergens were collected daily from 3 stations around Seoul. Skin prick tests to pollen were performed on children with allergic diseases. Ragweed pollen gradually increased between 1999 and 2005, decreased after 2005 and plateaued until 2009 (peak counts, 67 in 2003, 145 in 2005 and 83 grains/m(3)/day in 2007). Japanese hop pollen increased between 2002 and 2009 (peak counts, 212 in 2006 and 492 grains/m(3)/day in 2009). Sensitization rates to weed pollen, especially ragweed and Japanese hop in children with allergic diseases, increased annually (ragweed, 2.2% in 2000 and 2.8% in 2002; Japanese hop, 1.4% in 2000 and 1.9% in 2002). The age for sensitization to pollen gradually became younger since 2000 (4 to 6 yr of age, 3.5% in 1997 and 6.2% in 2009; 7 to 9 yr of age, 4.2% in 1997 and 6.4% in 2009). In conclusion, sensitization rates for weed pollens increase in Korean children given increasing pollen counts of ragweed and Japanese hop.

  17. Comparative virulence and competition between Nosema apis and Nosema ceranae in honey bees (Apis mellifera).

    PubMed

    Milbrath, Meghan O; van Tran, Toan; Huang, Wei-Fong; Solter, Leellen F; Tarpy, David R; Lawrence, Frank; Huang, Zachary Y

    2015-02-01

    Honey bees (Apis mellifera) are infected by two species of microsporidia: Nosema apis and Nosemaceranae. Epidemiological evidence indicates that N. ceranae may be replacing N. apis globally in A. mellifera populations, suggesting a potential competitive advantage of N. ceranae. Mixed infections of the two species occur, and little is known about the interactions among the host and the two pathogens that have allowed N. ceranae to become dominant in most geographical areas. We demonstrated that mixed Nosema species infections negatively affected honey bee survival (median survival=15-17days) more than single species infections (median survival=21days and 20days for N. apis and N. ceranae, respectively), with median survival of control bees of 27days. We found similar rates of infection (percentage of bees with active infections after inoculation) for both species in mixed infections, with N. apis having a slightly higher rate (91% compared to 86% for N. ceranae). We observed slightly higher spore counts in bees infected with N. ceranae than in bees infected with N. apis in single microsporidia infections, especially at the midpoint of infection (day 10). Bees with mixed infections of both species had higher spore counts than bees with single infections, but spore counts in mixed infections were highly variable. We did not see a competitive advantage for N. ceranae in mixed infections; N. apis spore counts were either higher or counts were similar for both species and more N. apis spores were produced in 62% of bees inoculated with equal dosages of the two microsporidian species. N. ceranae does not, therefore, appear to have a strong within-host advantage for either infectivity or spore growth, suggesting that direct competition in these worker bee mid-guts is not responsible for its apparent replacement of N. apis. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Zero-inflated Poisson model based likelihood ratio test for drug safety signal detection.

    PubMed

    Huang, Lan; Zheng, Dan; Zalkikar, Jyoti; Tiwari, Ram

    2017-02-01

    In recent decades, numerous methods have been developed for data mining of large drug safety databases, such as Food and Drug Administration's (FDA's) Adverse Event Reporting System, where data matrices are formed by drugs such as columns and adverse events as rows. Often, a large number of cells in these data matrices have zero cell counts and some of them are "true zeros" indicating that the drug-adverse event pairs cannot occur, and these zero counts are distinguished from the other zero counts that are modeled zero counts and simply indicate that the drug-adverse event pairs have not occurred yet or have not been reported yet. In this paper, a zero-inflated Poisson model based likelihood ratio test method is proposed to identify drug-adverse event pairs that have disproportionately high reporting rates, which are also called signals. The maximum likelihood estimates of the model parameters of zero-inflated Poisson model based likelihood ratio test are obtained using the expectation and maximization algorithm. The zero-inflated Poisson model based likelihood ratio test is also modified to handle the stratified analyses for binary and categorical covariates (e.g. gender and age) in the data. The proposed zero-inflated Poisson model based likelihood ratio test method is shown to asymptotically control the type I error and false discovery rate, and its finite sample performance for signal detection is evaluated through a simulation study. The simulation results show that the zero-inflated Poisson model based likelihood ratio test method performs similar to Poisson model based likelihood ratio test method when the estimated percentage of true zeros in the database is small. Both the zero-inflated Poisson model based likelihood ratio test and likelihood ratio test methods are applied to six selected drugs, from the 2006 to 2011 Adverse Event Reporting System database, with varying percentages of observed zero-count cells.

  19. Long-term viral suppression and immune recovery during first-line antiretroviral therapy: a study of an HIV-infected adult cohort in Hanoi, Vietnam.

    PubMed

    Tanuma, Junko; Matsumoto, Shoko; Haneuse, Sebastien; Cuong, Do Duy; Vu, Tuong Van; Thuy, Pham Thi Thanh; Dung, Nguyen Thi; Dung, Nguyen Thi Hoai; Trung, Nguyen Vu; Kinh, Nguyen Van; Oka, Shinichi

    2017-12-01

    Achieving viral suppression is key in the global strategy to end the HIV epidemic. However, the levels of viral suppression have yet to be described in many resource-limited settings. We investigated the time to virologic failure (VF; defined as a viral load of ≥1000 copies/ml) and changes in CD4 counts since starting antiretroviral therapy (ART) in a cohort of HIV-infected adults in Hanoi, Vietnam. Factors related to the time to VF and impaired early immune recovery (defined as not attaining an increase in 100 cells/mm 3 in CD4 counts at 24 months) were further analysed. From 1806 participants, 225 were identified as having VF at a median of 50 months of first-line ART. The viral suppression rate at 12 months was 95.5% and survival without VF was maintained above 90% until 42 months. An increase in CD4 counts from the baseline was greater in groups with lower baseline CD4 counts. A younger age (multivariate hazard ratio (HR) 0.75, vs. <30), hepatitis C (HCV)-antibody positivity (HR 1.43), and stavudine (d4T)-containing regimens (HR 1.4, vs. zidovudine (AZT)) were associated with earlier VF. Factors associated with impaired early immune recovery included the male sex (odds ratio (OR) 1.78), HCV-antibody positivity (OR 1.72), d4T-based regimens (OR 0.51, vs. AZT), and nevirapine-based regimens (OR 0.53, vs. efavirenz) after controlling for baseline CD4 counts. Durable high-rate viral suppression was observed in the cohort of patients on first-line ART in Vietnam. Our results highlight the need to increase adherence support among injection drug users and HCV co-infected patients. © 2017 The Authors. Journal of the International AIDS Society published by John Wiley & sons Ltd on behalf of the International AIDS Society.

  20. Count trends for migratory Bald Eagles reveal differences between two populations at a spring site along the Lake Ontario shoreline

    PubMed Central

    2016-01-01

    The recovery of Bald Eagles (Haliaeetus leucophalus), after DDT and other organochlorine insecticides were banned in the United States, can be regarded as one of the most iconic success stories resulting from the Endangered Species Act. Interest remains high in the recovery and growth of the Bald Eagle population. Common to evaluating growth and recovery rates are counts at nesting sites and analyses of individuals fledged per season. But this is merely one snapshot that ignores survival rates as eagles grow to maturity. By analyzing indices from migration counts, we get a different snapshot better reflecting the survival of young birds. Different populations of Bald Eagles breed at different sites at different times of the year. Typical migration count analyses do not separate the populations. A separation of two distinct populations can be achieved at spring count sites by taking advantage of the tendency for northern summer breeding birds to migrate north in spring earlier than southern winter breeding birds who disperse north later in spring. In this paper I analyze migratory indices at a spring site along Lake Ontario. The analysis shows that eagles considered to be primarily of the northern summer breeding population showed an estimated growth rate of 5.3 ± 0.85% (SE) per year with 49% of eagles tallied in adult plumage, whereas the migrants considered to be primarily of the southern breeding population had an estimated growth rate of 14.0 ± 1.79% with only 22% in adult plumage. Together these results argue that the populations of southern breeding Bald Eagles are growing at a substantially higher rate than northern breeding eagles. These findings suggest that aggregate population indices for a species at migration counting sites can sometimes obscure important differences among separate populations at any given site and that separating counts by time period can be a useful way to check for differences among sub-populations. PMID:27231647

  1. Estimation of population trajectories from count data

    USGS Publications Warehouse

    Link, W.A.; Sauer, J.R.

    1997-01-01

    Monitoring of changes in animal population size is rarely possible through complete censuses; frequently, the only feasible means of monitoring changes in population size is to use counts of animals obtained by skilled observers as indices to abundance. Analysis of changes in population size can be severely biased if factors related to the acquisition of data are not adequately controlled for. In particular we identify two types of observer effects: these correspond to baseline differences in observer competence, and to changes through time in the ability of individual observers. We present a family of models for count data in which the first of these observer effects is treated as a nuisance parameter. Conditioning on totals of negative binomial counts yields a Dirichlet compound multinomial vector for each observer. Quasi-likelihood is used to estimate parameters related to population trajectory and other parameters of interest; model selection is carried out on the basis of Akaike's information criterion. An example is presented using data on Wood thrush from the North American Breeding Bird Survey.

  2. Cryptographic robustness of a quantum cryptography system using phase-time coding

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molotkov, S. N.

    2008-01-15

    A cryptographic analysis is presented of a new quantum key distribution protocol using phase-time coding. An upper bound is obtained for the error rate that guarantees secure key distribution. It is shown that the maximum tolerable error rate for this protocol depends on the counting rate in the control time slot. When no counts are detected in the control time slot, the protocol guarantees secure key distribution if the bit error rate in the sifted key does not exceed 50%. This protocol partially discriminates between errors due to system defects (e.g., imbalance of a fiber-optic interferometer) and eavesdropping. In themore » absence of eavesdropping, the counts detected in the control time slot are not caused by interferometer imbalance, which reduces the requirements for interferometer stability.« less

  3. NICER discovers millisecond pulsations from the neutron star LMXB IGR J17379-3747

    NASA Astrophysics Data System (ADS)

    Strohmayer, T. E.; Ray, P. S.; Gendreau, K. C.; Bult, P. M.; Guillot, S.; Mahmoodifar, S.; Jaisawal, G. K.; Arzoumanian, Z.; Altamirano, D.; Bogdanov, S.; Chakrabarty, D.; Enoto, T.; Markwardt, C. B.; Ozel, F.; Ransom, S. M.

    2018-04-01

    Following a 2018 March 19 MAXI alert of a new outburst of the neutron star low-mass X-ray binary IGR J17379-3747 (ATel #11447), NICER has observed the source daily since 2018 March 29. From that date onward, the mean count rates detected each day through April 1 were 12.9, 11.0, 8.7, and 4.7 ct/s (0.5-12 keV), respectively.

  4. HIGH VOLTAGE GENERATOR

    DOEpatents

    Zito, G.V.

    1959-04-21

    This patent relates to high voltage supply circuits adapted for providing operating voltages for GeigerMueller counter tubes, and is especially directed to an arrangement for maintaining uniform voltage under changing conditions of operation. In the usual power supply arrangement for counter tubes the counter voltage is taken from across the power supply output capacitor. If the count rate exceeds the current delivering capaciiy of the capacitor, the capacitor voltage will drop, decreasing the counter voltage. The present invention provides a multivibrator which has its output voltage controlled by a signal proportional to the counting rate. As the counting rate increases beyond the current delivering capacity of the capacitor, the rectified voltage output from the multivibrator is increased to maintain uniform counter voltage.

  5. Testing the hierarchical assembly of massive galaxies using accurate merger rates out to z ˜ 1.5

    NASA Astrophysics Data System (ADS)

    Rodrigues, Myriam; Puech, M.; Flores, H.; Hammer, F.; Pirzkal, N.

    2018-04-01

    We established an accurate comparison between observationally and theoretically estimated major merger rates over a large range of mass (log Mbar/M⊙ =9.9-11.4) and redshift (z = 0.7-1.6). For this, we combined a new estimate of the merger rate from an exhaustive count of pairs within the virial radius of massive galaxies at z ˜ 1.265 and cross-validated with their morphology, with estimates from the morpho-kinematic analysis of two other samples. Theoretical predictions were estimated using semi-empirical models with inputs matching the properties of the observed samples, while specific visibility time-scales scaled to the observed samples were used. Both theory and observations are found to agree within 30 per cent of the observed value, which provides strong support to the hierarchical assembly of galaxies over the probed ranges of mass and redshift. Here, we find that ˜60 per cent of population of local massive (Mstellar =1010.3-11.6 M⊙) galaxies would have undergone a wet major merger since z = 1.5, consistently with previous studies. Such recent mergers are expected to result in the (re-)formation of a significant fraction of local disc galaxies.

  6. Probiotic Strawberry Yogurts: Microbiological, Chemical and Sensory Properties.

    PubMed

    Turgut, Tamer; Cakmakci, Songül

    2018-03-01

    This study was performed to determine the viability of Lactobacillus acidophilus and Bifidobacterium bifidum in yogurt made with strawberry marmalade (SM) and to examine the quality properties of probiotic yogurt. Acidity, pH, bacterial counts and sensory analysis of the yogurt samples were investigated on days 1, 3, 5, 7, 10 and 14 during storage at 4 °C. The survival rate of L. acidophilus was greater than that of B. bifidum. The viability of L. acidophilus decreased during the storage period, but B. bifidum numbers remained stable during the storage period. The highest L. acidophilus count (7.20 log cfu/g) was found in L. acidophilus + B. bifidum SM yogurt on day 1. The highest B. bifidum count (6.13 log cfu/g) was detected in yogurt containing L. acidophilus + B. bifidum SM yogurt on day 7. Yeast and mould counts of all yogurts increased during the storage period. Coliform bacteria and Staphylococcus aureus were not detected in the yogurt samples. The highest overall acceptance sensory score was observed in yogurts containing L. acidophilus. Considering the sensory and probiotic characteristics of all yogurt samples, this study suggested that strawberry yogurt with a suitable 5-7 day storage period can be produced with single L. acidophilus addition or single B. bifidum addition.

  7. Cosmic ray intensity gradients in the solar system

    NASA Technical Reports Server (NTRS)

    Mckibben, R. B.

    1975-01-01

    Recent progress in the determination of cosmic-ray intensity gradients is reviewed. Direct satellite measurements of the integral gradient are described together with various types of indirect measurements, including measurements of the Ar-37/Ar-39 ratio in samples from the Lost City meteorite, studies of anisotropies in neutron-monitor counting rates, and analysis of the sidereal diurnal anisotropy observed at a single point on earth. Nucleonic radial gradients and electron gradients measured by satellites in differential energy windows are discussed, and theoretical studies of the physical processes involved in these gradients are summarized. Observations of intensity gradients in heliographic latitude are reported.

  8. Plastic Scintillator Based Detector for Observations of Terrestrial Gamma-ray Flashes.

    NASA Astrophysics Data System (ADS)

    Barghi, M. R., Sr.; Delaney, N.; Forouzani, A.; Wells, E.; Parab, A.; Smith, D.; Martinez, F.; Bowers, G. S.; Sample, J.

    2017-12-01

    We present an overview of the concept and design of the Light and Fast TGF Recorder (LAFTR), a balloon borne gamma-ray detector designed to observe Terrestrial Gamma-Ray Flashes (TGFs). Terrestrial Gamma-Ray Flashes (TGFs) are extremely bright, sub-millisecond bursts of gamma-rays observed to originate inside thunderclouds coincident with lightning. LAFTR is joint institutional project built by undergraduates at the University of California Santa Cruz and Montana State University. It consists of a detector system fed into analog front-end electronics and digital processing. The presentation focuses specifically on the UCSC components, which consists of the detector system and analog front-end electronics. Because of the extremely high count rates observed during TGFs, speed is essential for both the detector and electronics of the instrument. The detector employs a fast plastic scintillator (BC-408) read out by a SensL Silicon Photomultiplier (SiPM). BC-408 is chosen for its speed ( 4 ns decay time) and low cost and availability. Furthermore, GEANT3 simulations confirm the scintillator is sensitive to 500 counts at 7 km horizontal distance from the TGF source (for a 13 km source altitude and 26 km balloon altitude) and to 5 counts out to 20 km. The signal from the SiPM has a long exponential decay tail and is sent to a custom shaping circuit board that amplifies and shapes the signal into a semi-Gaussian pulse with a 40 ns FWHM. The signal is then input to a 6-channel discriminator board that clamps the signal and outputs a Low Voltage Differential Signal (LVDS) for processing by the digital electronics.

  9. Extended range radiation dose-rate monitor

    DOEpatents

    Valentine, Kenneth H.

    1988-01-01

    An extended range dose-rate monitor is provided which utilizes the pulse pileup phenomenon that occurs in conventional counting systems to alter the dynamic response of the system to extend the dose-rate counting range. The current pulses from a solid-state detector generated by radiation events are amplified and shaped prior to applying the pulses to the input of a comparator. The comparator generates one logic pulse for each input pulse which exceeds the comparator reference threshold. These pulses are integrated and applied to a meter calibrated to indicate the measured dose-rate in response to the integrator output. A portion of the output signal from the integrator is fed back to vary the comparator reference threshold in proportion to the output count rate to extend the sensitive dynamic detection range by delaying the asymptotic approach of the integrator output toward full scale as measured by the meter.

  10. [An analysis of spectrum of allergen sensitization among patients with tree pollen allergy in Beijing].

    PubMed

    Wang, X Y; Ning, H Y; Chu, S M; Jiang, L; Pang, Y J; Jin, W T; Wang, S Q; Wang, X Y

    2017-12-05

    Objective: To explore the feature of allergic sensitization of tree pollen and the relationship between tree pollen and airborne pollen in Beijing. Method: Two thousand five hundred and twenty-one patients with allergic diseases were enrolled between January to July in 2017 in an allergy department. All patients received SPT of 8 kinds of tree pollen. Result: ①The overall tree pollen positive rate of SPT was 49.3% (1 244/2 521). Male had a higher positive rate than female (56.4% vs 45.0%, P <0.01) while child group had a higher positive rate than adult group (55.9% vs 48.6%, P <0.05). The poly sensitization was observed with a rate of 26.3%, take the percentage of 53.3% of the overall positive subjects. ②The highest sensitization rate was found in March (62.2%), followed by May (52.1%), the lowest was January (27.9%). There was a positive correlation between tree pollen sensitization rate and pollen count of each month ( r =0.929, P <0.01). ③Cypress had the highest positive rate (34.6%), followed by poplar (21.3%), the lowest was sophora (13.3%). The sensitization rate was positively correlated with pollen count among different tree pollen ( r =0.714, P <0.05). Conclusion: The main allergic pollen in Beijing was cypress. The tree pollen sensitization showed a seasonality with the peak in March. The sensitization status was tightly associated with the amount of airborne pollen. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  11. How many fish in a tank? Constructing an automated fish counting system by using PTV analysis

    NASA Astrophysics Data System (ADS)

    Abe, S.; Takagi, T.; Takehara, K.; Kimura, N.; Hiraishi, T.; Komeyama, K.; Torisawa, S.; Asaumi, S.

    2017-02-01

    Because escape from a net cage and mortality are constant problems in fish farming, health control and management of facilities are important in aquaculture. In particular, the development of an accurate fish counting system has been strongly desired for the Pacific Bluefin tuna farming industry owing to the high market value of these fish. The current fish counting method, which involves human counting, results in poor accuracy; moreover, the method is cumbersome because the aquaculture net cage is so large that fish can only be counted when they move to another net cage. Therefore, we have developed an automated fish counting system by applying particle tracking velocimetry (PTV) analysis to a shoal of swimming fish inside a net cage. In essence, we treated the swimming fish as tracer particles and estimated the number of fish by analyzing the corresponding motion vectors. The proposed fish counting system comprises two main components: image processing and motion analysis, where the image-processing component abstracts the foreground and the motion analysis component traces the individual's motion. In this study, we developed a Region Extraction and Centroid Computation (RECC) method and a Kalman filter and Chi-square (KC) test for the two main components. To evaluate the efficiency of our method, we constructed a closed system, placed an underwater video camera with a spherical curved lens at the bottom of the tank, and recorded a 360° view of a swimming school of Japanese rice fish (Oryzias latipes). Our study showed that almost all fish could be abstracted by the RECC method and the motion vectors could be calculated by the KC test. The recognition rate was approximately 90% when more than 180 individuals were observed within the frame of the video camera. These results suggest that the presented method has potential application as a fish counting system for industrial aquaculture.

  12. Mortality in members of HIV-1 serodiscordant couples in Africa and implications for antiretroviral therapy initiation: Results of analyses from a multicenter randomized trial

    PubMed Central

    2012-01-01

    Background The risk of HIV-1 related mortality is strongly related to CD4 count. Guidance on optimal timing for initiation of antiretroviral therapy (ART) is still evolving, but the contribution of HIV-1 infection to excess mortality at CD4 cell counts above thresholds for HIV-1 treatment has not been fully described, especially in resource-poor settings. To compare mortality among HIV-1 infected and uninfected members of HIV-1 serodiscordant couples followed for up to 24 months, we conducted a secondary data analysis examining mortality among HIV-1 serodiscordant couples participating in a multicenter, randomized controlled trial at 14 sites in seven sub-Saharan African countries. Methods Predictors of death were examined using Cox regression and excess mortality by CD4 count and plasma HIV-1 RNA was computed using Poisson regression for correlated data. Results Among 3295 HIV serodiscordant couples, we observed 109 deaths from any cause (74 deaths among HIV-1 infected and 25 among HIV-1 uninfected persons). Among HIV-1 infected persons, the risk of death increased with lower CD4 count and higher plasma viral levels. HIV-1 infected persons had excess mortality due to medical causes of 15.2 deaths/1000 person years at CD4 counts of 250 – 349 cells/μl and 8.9 deaths at CD4 counts of 350 – 499 cells/μl. Above a CD4 count of 500 cells/μl, mortality was comparable among HIV-1 infected and uninfected persons. Conclusions Among African serodiscordant couples, there is a high rate of mortality attributable to HIV-1 infection at CD4 counts above the current threshold (200 – 350 cells/μl) for ART initiation in many African countries. These data indicate that earlier initiation of treatment is likely to provide clinical benefit if further expansion of ART access can be achieved. Trial Registration Clinicaltrials.gov (NCT00194519) PMID:23130818

  13. The Effects of Gamma and Proton Radiation Exposure on Hematopoietic Cell Counts in the Ferret Model

    PubMed Central

    Sanzari, Jenine K.; Wan, X. Steven; Krigsfeld, Gabriel S.; Wroe, Andrew J.; Gridley, Daila S.; Kennedy, Ann R.

    2014-01-01

    Exposure to total-body radiation induces hematological changes, which can detriment one's immune response to wounds and infection. Here, the decreases in blood cell counts after acute radiation doses of γ-ray or proton radiation exposure, at the doses and dose-rates expected during a solar particle event (SPE), are reported in the ferret model system. Following the exposure to γ-ray or proton radiation, the ferret peripheral total white blood cell (WBC) and lymphocyte counts decreased whereas neutrophil count increased within 3 hours. At 48 hours after irradiation, the WBC, neutrophil, and lymphocyte counts decreased in a dose-dependent manner but were not significantly affected by the radiation type (γ-rays verses protons) or dose rate (0.5 Gy/minute verses 0.5 Gy/hour). The loss of these blood cells could accompany and contribute to the physiological symptoms of the acute radiation syndrome (ARS). PMID:25356435

  14. The GLOBE Earth Day 2004 Contrail Count-a-Thon

    NASA Technical Reports Server (NTRS)

    Chambers, Lin H.; Cole, Julia

    2004-01-01

    Early in 2004 the GLOBE Science team suggested a contrail count activity to celebrate Earth Day 2004, which was held this year on April 22nd in the United States and some other countries around the world. The GLOBE contrail team embraced this idea and developed a simplified data collection sheet for this special project. Information about the event was shared through the GLOBE site, UCAR and NASA press releases, the NASA portal (http://www.nasa.gov) and the CERES S'COOL Project (http://scool.larc.nasa.gov). On Earth Day, about 120 observations were received through the GLOBE Contrail Count-a-Thon website, about 70 contrail observations were received through regular GLOBE data reporting, and 19 contrail observations were received through regular S'COOL data reporting. Only observations between 11:00 and 13:00 local time were included in the Count-a-Thon. The event was reported in the Boulder Daily Camera beforehand and in the Oregon Register-Guard after the fact. It was also reported on National Public Radio s Day-to-Day show; whose host even submitted an observation. This poster discusses the Count-a-Thon experience and reports the results.

  15. Geometric Representation of Association between Categories

    ERIC Educational Resources Information Center

    Heiser, Willem J.

    2004-01-01

    Categories can be counted, rated, or ranked, but they cannot be measured. Likewise, persons or individuals can be counted, rated, or ranked, but they cannot be measured either. Nevertheless, psychology has realized early on that it can take an indirect road to measurement: What can be measured is the strength of association between categories in…

  16. Partial-Interval Estimation of Count: Uncorrected and Poisson-Corrected Error Levels

    ERIC Educational Resources Information Center

    Yoder, Paul J.; Ledford, Jennifer R.; Harbison, Amy L.; Tapp, Jon T.

    2018-01-01

    A simulation study that used 3,000 computer-generated event streams with known behavior rates, interval durations, and session durations was conducted to test whether the main and interaction effects of true rate and interval duration affect the error level of uncorrected and Poisson-transformed (i.e., "corrected") count as estimated by…

  17. The Objectivity, Reliability, and Validity of the OSU Step Test for College Males

    ERIC Educational Resources Information Center

    Santa Maria, D. L.; And Others

    1976-01-01

    The O.S.U. Step Test was administered to 68 male university students to determine the objectivity of three methods of monitering heart rate--subjects count, investigator's count, and ECG records--with results indicating that the investigator was significantly more accurate in heart rate determination than were the subjects. (MB)

  18. Transition-Edge Sensor Pixel Parameter Design of the Microcalorimeter Array for the X-Ray Integral Field Unit on Athena

    NASA Technical Reports Server (NTRS)

    Smith, S. J.; Adams, J. S.; Bandler, S. R.; Betancourt-Martinez, G. L.; Chervenak, J. A.; Chiao, M. P.; Eckart, M. E.; Finkbeiner, F. M.; Kelley, R. L.; Kilbourne, C. A.; hide

    2016-01-01

    The focal plane of the X-ray integral field unit (X-IFU) for ESA's Athena X-ray observatory will consist of approximately 4000 transition edge sensor (TES) x-ray microcalorimeters optimized for the energy range of 0.2 to 12 kiloelectronvolts. The instrument will provide unprecedented spectral resolution of approximately 2.5 electronvolts at energies of up to 7 kiloelectronvolts and will accommodate photon fluxes of 1 milliCrab (90 counts per second) for point source observations. The baseline configuration is a uniform large pixel array (LPA) of 4.28 arcseconds pixels that is read out using frequency domain multiplexing (FDM). However, an alternative configuration under study incorporates an 18 by × 18 small pixel array (SPA) of 2 arcseconds pixels in the central approximately 36 arcseconds region. This hybrid array configuration could be designed to accommodate higher fluxes of up to 10 milliCrabs (900 counts per second) or alternately for improved spectral performance (less than 1.5 electronvolts) at low count-rates. In this paper we report on the TES pixel designs that are being optimized to meet these proposed LPA and SPA configurations. In particular we describe details of how important TES parameters are chosen to meet the specific mission criteria such as energy resolution, count-rate and quantum efficiency, and highlight performance trade-offs between designs. The basis of the pixel parameter selection is discussed in the context of existing TES arrays that are being developed for solar and x-ray astronomy applications. We describe the latest results on DC biased diagnostic arrays as well as large format kilo-pixel arrays and discuss the technical challenges associated with integrating different array types on to a single detector die.

  19. Evaluation of dead-time corrections for post-radionuclide-therapy (177)Lu quantitative imaging with low-energy high-resolution collimators.

    PubMed

    Celler, Anna; Piwowarska-Bilska, Hanna; Shcherbinin, Sergey; Uribe, Carlos; Mikolajczak, Renata; Birkenfeld, Bozena

    2014-01-01

    Dead-time (DT) effects rarely cause problems in diagnostic single-photon emission computed tomography (SPECT) studies; however, in post-radionuclide-therapy imaging, DT can be substantial. Therefore, corrections may be necessary if quantitative images are used in image-based dosimetry or for evaluation of therapy outcomes. This task is particularly challenging if low-energy collimators are used. Our goal was to design a simple method to determine the dead-time correction factor (DTCF) without the need for phantom experiments and complex calculations. Planar and SPECT/CT scans of a water phantom containing a 70 ml bottle filled with lutetium-177 (Lu) were acquired over 60 days. Two small Lu markers were used in all scans. The DTCF based on the ratio of observed to true count rates measured over the entire spectrum and using photopeak primary photons only was estimated for phantom (DT present) and marker (no DT) scans. In addition, variations in counts in SPECT projections (potentially caused by varying bremsstrahlung and scatter) were investigated. For count rates that were about two-fold higher than typically seen in post-therapy Lu scans, the maximum DTCF reached a level of about 17%. The DTCF values determined directly from the phantom experiments using the total energy spectrum and photopeak counts only were equal to 13 and 16%, respectively. They were closely matched by those from the proposed marker-based method, which uses only two energy windows and measures photopeak primary photons (15-17%). A simple, marker-based method allowing for determination of the DTCF in high-activity Lu imaging studies has been proposed and validated using phantom experiments.

  20. 29 CFR 778.318 - Productive and nonproductive hours of work.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Special Problems Effect of Failure to Count Or Pay for Certain Working Hours § 778.318 Productive and... Act; such nonproductive working hours must be counted and paid for. (b) Compensation payable for... which such nonproductive hours are properly counted as working time but no special hourly rate is...

  1. Photon-Counting Multikilohertz Microlaser Altimeters for Airborne and Spaceborne Topographic Measurements

    NASA Technical Reports Server (NTRS)

    Degnan, John J.; Smith, David E. (Technical Monitor)

    2000-01-01

    We consider the optimum design of photon-counting microlaser altimeters operating from airborne and spaceborne platforms under both day and night conditions. Extremely compact Q-switched microlaser transmitters produce trains of low energy pulses at multi-kHz rates and can easily generate subnanosecond pulse-widths for precise ranging. To guide the design, we have modeled the solar noise background and developed simple algorithms, based on Post-Detection Poisson Filtering (PDPF), to optimally extract the weak altimeter signal from a high noise background during daytime operations. Practical technology issues, such as detector and/or receiver dead times, have also been considered in the analysis. We describe an airborne prototype, being developed under NASA's instrument Incubator Program, which is designed to operate at a 10 kHz rate from aircraft cruise altitudes up to 12 km with laser pulse energies on the order of a few microjoules. We also analyze a compact and power efficient system designed to operate from Mars orbit at an altitude of 300 km and sample the Martian surface at rates up to 4.3 kHz using a 1 watt laser transmitter and an 18 cm telescope. This yields a Power-Aperture Product of 0.24 W-square meter, corresponding to a value almost 4 times smaller than the Mars Orbiting Laser Altimeter (0. 88W-square meter), yet the sampling rate is roughly 400 times greater (4 kHz vs 10 Hz) Relative to conventional high power laser altimeters, advantages of photon-counting laser altimeters include: (1) a more efficient use of available laser photons providing up to two orders of magnitude greater surface sampling rates for a given laser power-telescope aperture product; (2) a simultaneous two order of magnitude reduction in the volume, cost and weight of the telescope system; (3) the unique ability to spatially resolve the source of the surface return in a photon counting mode through the use of pixellated or imaging detectors; and (4) improved vertical and transverse spatial resolution resulting from both (1) and (3). Furthermore, because of significantly lower laser pulse energies, the microaltimeter is inherently more eyesafe to observers on the ground and less prone to internal optical damage, which can terminate a space mission prematurely.

  2. An investigation of the trade-off between the count level and image quality in myocardial perfusion SPECT using simulated images: the effects of statistical noise and object variability on defect detectability

    NASA Astrophysics Data System (ADS)

    He, Xin; Links, Jonathan M.; Frey, Eric C.

    2010-09-01

    Quantum noise as well as anatomic and uptake variability in patient populations limits observer performance on a defect detection task in myocardial perfusion SPECT (MPS). The goal of this study was to investigate the relative importance of these two effects by varying acquisition time, which determines the count level, and assessing the change in performance on a myocardial perfusion (MP) defect detection task using both mathematical and human observers. We generated ten sets of projections of a simulated patient population with count levels ranging from 1/128 to around 15 times a typical clinical count level to simulate different levels of quantum noise. For the simulated population we modeled variations in patient, heart and defect size, heart orientation and shape, defect location, organ uptake ratio, etc. The projection data were reconstructed using the OS-EM algorithm with no compensation or with attenuation, detector response and scatter compensation (ADS). The images were then post-filtered and reoriented to generate short-axis slices. A channelized Hotelling observer (CHO) was applied to the short-axis images, and the area under the receiver operating characteristics (ROC) curve (AUC) was computed. For each noise level and reconstruction method, we optimized the number of iterations and cutoff frequencies of the Butterworth filter to maximize the AUC. Using the images obtained with the optimal iteration and cutoff frequency and ADS compensation, we performed human observer studies for four count levels to validate the CHO results. Both CHO and human observer studies demonstrated that observer performance was dependent on the relative magnitude of the quantum noise and the patient variation. When the count level was high, the patient variation dominated, and the AUC increased very slowly with changes in the count level for the same level of anatomic variability. When the count level was low, however, quantum noise dominated, and changes in the count level resulted in large changes in the AUC. This behavior agreed with a theoretical expression for the AUC as a function of quantum and anatomical noise levels. The results of this study demonstrate the importance of the tradeoff between anatomical and quantum noise in determining observer performance. For myocardial perfusion imaging, it indicates that, at current clinical count levels, there is some room to reduce acquisition time or injected activity without substantially degrading performance on myocardial perfusion defect detection.

  3. The relationship between pollen count levels and prevalence of Japanese cedar pollinosis in Northeast Japan.

    PubMed

    Honda, Kohei; Saito, Hidekazu; Fukui, Naoko; Ito, Eiko; Ishikawa, Kazuo

    2013-09-01

    The prevalence of Japanese cedar (JC) pollinosis in Japanese children is increasing. However, few studies have reported the relationship between pollen count levels and the prevalence of pollinosis. To evaluate the relationship between JC pollen count levels and the prevalence of pollinosis in children, we investigated the sensitization and development of symptoms for JC pollen in two areas of Akita in northeast Japan with contrasting levels of exposure to JC pollen. The study population consisted of 339 elementary school students (10-11 years of age) from the coastal and mountainous areas of Akita in 2005-2006. A questionnaire about symptoms of allergic rhinitis was filled out by the students' parents. A blood sample was taken to determine specific IgE antibodies against five common aeroallergens. The mean pollen count in the mountainous areas was two times higher than that in the coastal areas in 1996-2006. The prevalence rates of nasal allergy symptoms and sensitization for mites were almost the same in both areas. On the other hand, the rates of nasal allergy symptoms and sensitization for JC pollen were significantly higher in the mountainous areas than in the coastal areas. The rate of the development of symptoms among children sensitized for JC pollen was almost the same in both areas. These results suggest that pollen count levels may correlate with the rate of sensitization for JC pollinosis, but may not affect the rate of onset among sensitized children in northeast Japan.

  4. Influence of social and built environment features on children walking to school: an observational study.

    PubMed

    Rothman, Linda; To, Teresa; Buliung, Ron; Macarthur, Colin; Howard, Andrew

    2014-03-01

    To estimate the proportion of children living within walking distance who walk to school in Toronto, Canada and identify built and social environmental correlates of walking. Observational counts of school travel mode were done in 2011, at 118 elementary schools. Built environment data were obtained from municipal sources and school field audits and mapped onto school attendance boundaries. The influence of social and built environmental features on walking counts was analyzed using negative binomial regression. The mean proportion observed walking was 67% (standard deviation=14.0). Child population (incidence rate ratio (IRR) 1.36), pedestrian crossover (IRR 1.32), traffic light (IRR 1.19), and intersection densities (IRR 1.03), school crossing guard (IRR 1.14) and primary language other than English (IRR 1.20) were positively correlated with walking. Crossing guard presence reduced the influence of other features on walking. This is the first large observational study examining school travel mode and the environment. Walking proportions were higher than those previously reported in Toronto, with large variability. Associations between population density and several roadway design features and walking were confirmed. School crossing guards may override the influence of roadway features on walking. Results have important implications for policies regarding walking promotion. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  5. Evaluation of cell proliferation in malignant and potentially malignant oral lesions

    PubMed Central

    Madan, Mani; Chandra, Shaleen; Raj, Vineet; Madan, Rohit

    2015-01-01

    Aims: To evaluate the cell proliferation rate by the expression of proliferating cell nuclear antigen (PCNA) and argyrophilic nucleolar organizing region (AgNOR) counts and to assess its usefulness as a marker for malignant potential in oral epithelial lesions. Materials and Methods: The study group included 30 cases of leukoplakia, 15 nondysplastic (NDL), 15 dysplastic (DL), 15 cases of oral squamous cell carcinoma (OSCC) and 5 cases of normal oral mucosa. Formalin fixed paraffin embedded tissues were subjected to immunohistochemical staining for PCNA and AgNOR technique. The PCNA labeling index (LI) and the AgNOR dots were evaluated for the entire sample. Statistical Analysis Used: ANOVA, Tukey honestly significant difference, Pearson's correlation. Results: In this study, the AgNOR count of OSCC was lower than the DL lesions moreover the AgNOR counts were found to be higher in normal mucosa as compared to the DL and the NDL epithelium. The study results also showed that the mean AgNOR count failed to distinguish between DL and NDL lesions. Overall we observed increased PCNA expression from normal epithelium to NDL to DL lesion. Conclusions: Based on the findings of the present study on oral epithelial precancerous and cancerous lesions we conclude that mean AgNOR count alone cannot be a valuable parameter to distinguish between the normal, NDL, DL epithelium and OSCC but, on the other hand, we found out that PCNA can be a useful biomarker for delineating normal epithelium from DL epithelium and OSCC. PMID:26980956

  6. Evaluation of cell proliferation in malignant and potentially malignant oral lesions.

    PubMed

    Madan, Mani; Chandra, Shaleen; Raj, Vineet; Madan, Rohit

    2015-01-01

    To evaluate the cell proliferation rate by the expression of proliferating cell nuclear antigen (PCNA) and argyrophilic nucleolar organizing region (AgNOR) counts and to assess its usefulness as a marker for malignant potential in oral epithelial lesions. The study group included 30 cases of leukoplakia, 15 nondysplastic (NDL), 15 dysplastic (DL), 15 cases of oral squamous cell carcinoma (OSCC) and 5 cases of normal oral mucosa. Formalin fixed paraffin embedded tissues were subjected to immunohistochemical staining for PCNA and AgNOR technique. The PCNA labeling index (LI) and the AgNOR dots were evaluated for the entire sample. ANOVA, Tukey honestly significant difference, Pearson's correlation. In this study, the AgNOR count of OSCC was lower than the DL lesions moreover the AgNOR counts were found to be higher in normal mucosa as compared to the DL and the NDL epithelium. The study results also showed that the mean AgNOR count failed to distinguish between DL and NDL lesions. Overall we observed increased PCNA expression from normal epithelium to NDL to DL lesion. Based on the findings of the present study on oral epithelial precancerous and cancerous lesions we conclude that mean AgNOR count alone cannot be a valuable parameter to distinguish between the normal, NDL, DL epithelium and OSCC but, on the other hand, we found out that PCNA can be a useful biomarker for delineating normal epithelium from DL epithelium and OSCC.

  7. Different degree of immune recovery using antiretroviral regimens with Vonavir or Zidovudine/Lamivudine and Efavirenz in Patients receiving first line treatment in Iran.

    PubMed

    Sadeghi, Leila; Moallemi, Samaneh; Tabatabai, Reza Adl; Esmaeilzadeh, Ali; Ahsani-Nasab, Sara; Ahmadi, Niloofar Eghbal; Bayanolhagh, Saeed; Lolaie, Mahin; Narouei, Arsalan; Alinaghi, Ahmad; Mohraz, Minoo

    2018-01-07

    The initial ART regimens used by most national treatment guidelines in resource-limited settings include 2 nucleoside reverse-transcriptase inhibitors (NRTIs) and 1 non-nucleoside reverse-transcriptase inhibitor (NNRTI). The NRTIshave consistedof Zidovudine (AZT) or Stavudine (d4T) with Lamivudine (3TC); the NNRTI component hasbeen Nevirapine (NVP) or Efavirenz (EFV). There exists few data indicating if Vonavir is more effective in increasing CD4+ T cell counts or other first-line drugs of ART.Immunological outcomes of 134 individuals who just started antiretroviral therapy with Vonavir or Zidovudine/Lamivudine and Efavirenzanalyzed. Immunological response was then assessed during 28 weeks and indicated significant CD4+ T cell increase in both groups. The increase in CD4+ T cell counts was greater in Zidovudine/Lamivudine and Efavirenz treated group. A rapid CD4+ T cell increase occurred after the first 12 weeks of therapy in Vonavir treated group with initial CD4+ T cell counts ≤100 despite the individuals with higher CD4+ T cell counts. As previous studies, we observed the noticeable increase rate of CD4+ Tcells is in the first three months of therapy. A rapid CD4+ Tcell increase occurred shortly after beginning anti retroviraltherapy using either Vonaviror Zidovudine/Lamivudine and Efavirenz. Late increases in CD4+ T cell counts are more pronounced in therapy using Zidovudine/Lamivudine and Efavirenz. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Longitudinal research on the oral environment of elderly wearing fixed or removable prostheses.

    PubMed

    Tanaka, Junko; Tanaka, Masahiro; Kawazoe, Takayoshi

    2009-04-01

    The purpose of this study was to investigate oral environmental risk factors involved in caries incidence in the elderly. We investigated the relationship between the oral environment factors of the elderly with both fixed prostheses and removable prostheses at baseline and at follow-up and examined time-course changes of each oral environmental factor by prosthesis type. The subject group consisted 11 elderly patients with fixed prostheses and 11 who wore removable prostheses. We examined oral environmental factors by saliva tests. Five oral environmental factors were examined: the stimulated salivary flow rate, buffering capacity, and the counts of mutans streptococci (SM), lactobacilli (LB), and Candida (CA). We compared these factors for subjects with fixed prostheses and those wearing removable prostheses at baseline and at follow-up. Furthermore, 3-year changes in the factors of each oral environment were compared and evaluated. Significant differences were observed between the two groups in the salivary microbial counts of SM and LB at baseline and at follow-up. The LB counts increased in the Denture group during the 3-year period and significant differences were noted. We found that fixed prostheses are less cariogenic, and removable prostheses cause an increase in the cariogenic bacterial count. Regarding time-course changes by the type of prosthesis, the LB count tended to increase in the subjects with removable prostheses. The risk of caries due to a fixed prosthesis may be lower than that of removable prostheses.

  9. The significance of trilineage myelodysplasia in de novo acute myeloblastic leukemia: clinical and laboratory features.

    PubMed

    Lima, C S; Vassalo, J; Lorand-Metze, I; Bechelli, A P; Souza, C A

    1997-01-01

    A prospective study was undertaken to elucidate the clinical and laboratory differences between de novo acute myeloid leukemia (AML) and AML with trilineage myelodysplasia (AML-TMDS). One hundred and seven patients with AML were diagnosed at the University Hospital between January 1987 and July 1992, and were followed until July 1995. TMDS was identified in 17 of them (16%). With regard to age and sex distribution no difference was found between AML patients with and without TMDS (p = 0.43, p = 0.54, respectively). The duration of symptoms at presentation in AML-TMDS was similar to those observed in de novo AML (p = 0.29). Hemoglobin values and platelet counts were similar in both groups of patients (p = 0.45, p = 0.44, respectively). However, peripheral white blood cell and neutrophil counts, as well as blast counts in AML-TMDS patients were lower than those observed in AML without TMDS patients (p < 0.001 for all of them). Bone marrow blast counts in de novo AML were higher than the values observed in AML-TMDS patients (p < 0.001). TMDS occurred predominantly in M2 and M6 FAB types, and was absent in the M3 type. Bone marrow histology showed no particular feature that could be of diagnostic relevance. The remission rates were similar in both groups of patients (p = 0.55). The same was true for the probability of disease-free survival and overall survival during the period of study (p = 0.50, p = 0.33, respectively). These results suggest that: 1) in AML-TMDS patients, leukemia transformation occurs in a more undifferentiated pluripotent stem cell, leading to a dysplastic residual hemopoiesis besides the blast proliferation; 2) the incidence of TMDS in our group of patients did not influence the clinical outcome after treatment of the disease.

  10. Comparative study of effect of Withania somnifera as an adjuvant to DOTS in patients of newly diagnosed sputum smear positive pulmonary tuberculosis.

    PubMed

    Kumar, Ranjeet; Rai, Jaswant; Kajal, N C; Devi, Pushpa

    2018-07-01

    Ashwagandha (Withania somnifera Linn.) a rejuvenative herb has long been used as an immunomodulator in Indian subcontinent. As immunity plays an important role in pathogenesis and treatment of tuberculosis (TB), so role of W. somnifera as an adjuvant has been studied on selected parameter. A randomized, double-blind placebo-control study was conducted in two groups of 60 newly diagnosed sputum smear positive pulmonary TB patients on Directly Observed Treatment - short course (DOTS) regime. W. somnifera root extract or placebo capsules were given as add-on therapy for duration of 12 weeks. Effects on sputum conversion, Hemoglobin (Hb), body weight, Erythrocyte Sedimentation Rate (ESR), RBC counts, WBC counts, CD4 and CD8 counts, Serum Glutamic-Oxaloacetic Transaminase (SGOT), Serum Glutamic-Pyruvic Transaminase (SGPT), serum uric acid and HRQL (Health Related Quality of Life) Index scores were studied. At the end of 8 weeks, sputum conversion was seen in 86.6% patients in study group and 76.6% in placebo group. At the end of 12 weeks a highly significant increase was seen in both CD4 and CD8 counts in study group. A raised SGOT and SGPT levels (>35IU/L) were observed in 16.6% and 33.3% patients in study group; 43.33% and 53.33% in the placebo group of patients. Elevated serum uric acid levels (>6mg/dl) were observed in 20% and 33.33% in study and placebo group respectively. Average gain in HRQL score was better in patients of study group. Use of W. somnifera as an adjuvant in conjunction with anti-TB drugs used as DOTS showed a favorable effect on symptoms and immunological parameters in patients with pulmonary TB. Copyright © 2017 Tuberculosis Association of India. Published by Elsevier B.V. All rights reserved.

  11. A high performance neutron spectrometer for planetary hydrogen measurement

    NASA Astrophysics Data System (ADS)

    Naito, Masayuki; Hasebe, Nobuyuki; Nagaoka, Hiroshi; Ishii, Junya; Aoki, Daisuke; Shibamura, Eido; Kim, Kyeong J.; Matias-Lopes, José A.; Martínez-Frías, Jesús

    2017-08-01

    The elemental composition and its distribution on planetary surface provide important constraints on the origin and evolution of the planetary body. The nuclear spectrometer consisting of a neutron spectrometer and a gamma-ray spectrometer obtains elemental compositions by remote sensing. Especially, the neutron spectrometer is able to determine the hydrogen concentration, a piece of information that plays an important role in thermal history of the planets. In this work, numerical and experimental studies on the neutron spectrometer for micro-satellite application were conducted. It is found that background count rate of neutron produced from micro-satellite is very small, which enables to obtain successful results in short time observation. The neutron spectrometer combining a lithium-6 glass scintillator with a boron loaded plastic scintillator was used to be able to detect neutrons in different energy ranges. It was experimentally confirmed that the neutron signals from these scintillators were successfully discriminated by the difference of scintillation decay time between two detectors. The measurement of neutron count rates of two scintillators is found to determine hydrogen concentration on the planetary surfaces in the future missions.

  12. Application of Positron Doppler Broadening Spectroscopy to the Measurement of the Uniformity of Composite Materials

    NASA Astrophysics Data System (ADS)

    Quarles, C. A.; Sheffield, Thomas; Stacy, Scott; Yang, Chun

    2009-03-01

    The uniformity of rubber-carbon black composite materials has been investigated with positron Doppler Broadening Spectroscopy (DBS). The number of grams of carbon black (CB) mixed into one hundred grams of rubber, phr, is used to characterize a sample. A typical concentration for rubber in tires is 50 phr. The S parameter measured by DBS has been found to depend on the phr of the sample as well as the type of rubber and carbon black. The variation in carbon black concentration within a surface area of about 5 mm diameter can be measured by moving a standard Na-22 or Ge-68 positron source over an extended sample. The precision of the concentration measurement depends on the dwell time at a point on the sample. The time required to determine uniformity over an extended sample can be reduced by running with much higher counting rate than is typical in DBS and correcting for the systematic variation of S parameter with counting rate. Variation in CB concentration with mixing time at the level of about 0.5% has been observed.

  13. Observations on cattle schistosomiasis in the Sudan, a study in comparative medicine. III. Field testing of an irradiated Schistosoma bovis vaccine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majid, A.A.; Bushera, H.O.; Saad, A.M.

    1980-05-29

    Previous work has shown that cattle can acquire a strong resistance to Schistosoma bovis infection following repeated natural exposure. Partial resistance to a laboratory challenge with S. bovis has also been demonstrated in calves after immunization with an irradiated schistosomular or cercarial vaccine. The aim of the present study was to see whether this type of caccine could protect calves under the very different conditions of natural exposure to S. bovis in the field. Thirty 6- to 9-month-old calves were each immunized with 10,000 irradiated S. bovis schistosomula by intramuscular injection and 8 weeks later were released into an enzooticmore » area along with 30 unvaccinated animals. The calves were followed up for 10 months, during which period protection was evidenced by a lower mortality rate, a slower rate of acquisition of infection, and lower fecal egg counts in the vaccinated calves. Necropsy of the survivors showed 60 to 70% reductions in worm and tissue egg counts of the vaccinated calves as compared to those not vaccinated.« less

  14. Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

    NASA Astrophysics Data System (ADS)

    Lockhart, M.; Henzlova, D.; Croft, S.; Cutler, T.; Favalli, A.; McGahee, Ch.; Parker, R.

    2018-01-01

    Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli(DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory and implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. The current paper discusses and presents the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. In order to assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. The DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.

  15. MINERAL METABOLISM OF FRACTURES OF THE TIBIA IN MAN STUDIED WITH EXTERNAL COUNTING OF Sr$sup 8$$sup 5$

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendberg, B.

    1961-01-01

    A study was made of 51 adult patients with tibial fractures by external counting with scintillation detectors over the thighs, knees, and tibias during a 14-day period after intravenous injection of 25 to 50 mu c Sr/sup 85/. The pattern of activity curves recorded over the fractured leg compared to those recorded over the control leg varied significantly with the age of the fracture (2 days to 9 yr). Increased uptake of Sr/sup 85/ was observed in all cases. The activity ratio fracture/control tibia obtained 14 days after injection rose during the 1st months after fracture to reach a peakmore » value 6 to 8 months after fracture. The mean 14-day fracture/ control ratios obtained 5 to 10 months after fracture was 15.5 plus or minus 7.2; then it dropped. Even 6 to 9 yr after fracture the counting rate over the fracture was higher than that over the intact tibia. No differences in activity uptake were observed between normally healing fractures and fractures showing delayed or nonunion. Activity curves obtained over the thigh, knee, and tibia of the fractured and intact legs 1 to l4 days after injection of Sr/sup 85/ could be simulated on the basis of a 2-compartment model for the kinetics of Sr in the body. Based on this kinetic analysis the externally recorded Sr/sup 85/ activity values may be interpreted as follows: The activity ratios fractured/intact leg obtained during early intervals after injection are mainly related to differences in the size of the exchangeable mineral spaces under the detector. The 14-day activity ratio of 2 anatomically comparable locations may be used as a relative index of the difference in the accretion rate (rate of irreversible deposition of bone mineral) in these locations, but is somewhat lower than the absolute dfference in the accretion rate. The bone salt laid down in the fracture callus is derived from the body fluids. The accretion rate in the fracture region is increased within a week of the fracture. It rapidly increases during the first months after fracture to reach a peak value at 6 to 8 months after fracture. The accretion rate in the entire fractured leg is increased some months after fracture. The traumatic osteopenia is caused by increased resorption and not by decreased accretion. (H.H.D.)« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisk, William J.; Sullivan, Douglas

    This pilot scale study evaluated the counting accuracy of two people counting systems that could be used in demand controlled ventilation systems to provide control signals for modulating outdoor air ventilation rates. The evaluations included controlled challenges of the people counting systems using pre-planned movements of occupants through doorways and evaluations of counting accuracies when naive occupants (i.e., occupants unaware of the counting systems) passed through the entrance doors of the building or room. The two people counting systems had high counting accuracy accuracies, with errors typically less than 10percent, for typical non-demanding counting events. However, counting errors were highmore » in some highly challenging situations, such as multiple people passing simultaneously through a door. Counting errors, for at least one system, can be very high if people stand in the field of view of the sensor. Both counting system have limitations and would need to be used only at appropriate sites and where the demanding situations that led to counting errors were rare.« less

  17. Exfoliation rate of mammary epithelial cells in milk on bovine mastitis caused by Staphylococcus aureus is associated with bacterial load.

    PubMed

    Nagasawa, Yuya; Kiku, Yoshio; Sugawara, Kazue; Tanabe, Fuyuko; Hayashi, Tomohito

    2018-01-01

    The exfoliation rate of mammary epithelial cells (MECs) in milk is affected by physiological, breeding and environmental factors. Little is known about the relationship between the MEC exfoliation into milk and mammary-infected Staphylococcus aureus (S. aureus) load on bovine mastitis caused by S. aureus. The aim of this study was to investigate the relationship between S. aureus load and the proportion of MEC exfoliation in milk using five substantial bovine mastitis models. In 64 randomly extracted milk samples from udders at 3-21 days after S. aureus infusion, there were various samples with different numbers of S. aureus counts and somatic cell counts. No significant correlations were found between the S. aureus counts and somatic cell count (r = 0.338). In contrast, a significant correlation was noted between S. aureus counts and the proportion of cytokeratin-positive cells in the milk from the infused udders (r = 0.734, P < 0.01). In conclusion, the increasing MEC exfoliation rate in milk from mastitis udders caused by S. aureus may contribute to reduced milk yield. © 2017 Japanese Society of Animal Science.

  18. Addressing immunization registry population inflation in adolescent immunization rates.

    PubMed

    Robison, Steve G

    2015-01-01

    While U.S. adolescent immunization rates are available annually at national and state levels, finding pockets of need may require county or sub-county information. Immunization information systems (IISs) are one tool for assessing local immunization rates. However, the presence of IIS records dating back to early childhood and challenges in capturing mobility out of IIS areas typically leads to denominator inflation. We examined the feasibility of weighting adolescent immunization records by length of time since last report to produce more accurate county adolescent counts and immunization rates. We compared weighted and unweighted adolescent denominators from the Oregon ALERT IIS, along with county-level Census Bureau estimates, with school enrollment counts from Oregon's annual review of seventh-grade school immunization compliance for public and private schools. Adolescent immunization rates calculated using weighted data, for the state as a whole, were also checked against comparable National Immunization Survey (NIS) rates. Weighting individual records by the length of time since last activity substantially improved the fit of IIS data to county populations for adolescents. A nonlinear logarithmic (ogive) weight produced the best fit to the school count data of all examined estimates. Overall, the ogive weighted results matched NIS adolescent rates for Oregon. The problem of mobility-inflated counts of teenagers can be addressed by weighting individual records based on time since last immunization. Well-populated IISs can rely on their own data to produce adolescent immunization rates and find pockets of need.

  19. Parallel Group and Sunspot Counts from SDO/HMI and AAVSO Visual Observers (Abstract)

    NASA Astrophysics Data System (ADS)

    Howe, R.; Alvestad, J.

    2015-06-01

    (Abstract only) Creating group and sunspot counts from the SDO/HMI detector on the Solar Dynamics Observatory (SDO) satellite requires software that calculates sunspots from a “white light” intensity-gram (CCD image) and group counts from a filtered CCD magneto-gram. Images from the satellite come from here http://jsoc.stanford.edu/data/hmi/images/latest/ Together these two sets of images can be used to estimate the Wolf number as W = (10g + s), which is used to calculate the American Relative index. AAVSO now has approximately two years of group and sunspot counts in the SunEntry database as SDOH observer Jan Alvestad. It is important that we compare these satellite CCD image data with our visual observer daily submissions to determine if the SDO/HMI data should be included in calculating the American Relative index. These satellite data are continuous observations with excellent seeing. This contrasts with “snapshot” earth-based observations with mixed seeing. The SDO/HIM group and sunspot counts could be considered unbiased, except that they show a not normal statistical distribution when compared to the overall visual observations, which show a Poisson distribution. One challenge that should be addressed by AAVSO using these SDO/HMI data is the splitting of groups and deriving group properties from the magneto-grams. The filtered CCD detector that creates the magento-grams is not something our visual observers can relate too, unless they were to take CCD images in H-alpha and/or the Calcium spectrum line. So, questions remain as to how these satellite CCD image counts can be integrated into the overall American Relative index.

  20. Total motile sperm count has a superior predictive value over the WHO 2010 cut-off values for the outcomes of intracytoplasmic sperm injection cycles.

    PubMed

    Borges, E; Setti, A S; Braga, D P A F; Figueira, R C S; Iaconelli, A

    2016-09-01

    The objective of this study was to compare (i) the intracytoplasmic sperm injection outcomes among groups with different total motile sperm count ranges, (ii) the intracytoplasmic sperm injection outcomes between groups with normal and abnormal total motile sperm count, and (iii) the predictive values of WHO 2010 cut-off values and pre-wash total motile sperm count for the intracytoplasmic sperm injection outcomes, in couples with male infertility. This study included data from 518 patients undergoing their first intracytoplasmic sperm injection cycle as a result of male infertility. Couples were divided into five groups according to their total motile sperm count: Group I, total motile sperm count <1 × 10(6) ; group II, total motile sperm count 1-5 × 10(6) ; group III, total motile sperm count 5-10 × 10(6) ; group IV, total motile sperm count 10-20 × 10(6) ; and group V, total motile sperm count >20 × 10(6) (which was considered a normal total motile sperm count value). Then, couples were grouped into an abnormal and normal total motile sperm count group. The groups were compared regarding intracytoplasmic sperm injection outcomes. The predictive values of WHO 2010 cut-off values and total motile sperm count for the intracytoplasmic sperm injection outcomes were also investigated. The fertilization rate was lower in total motile sperm count group I compared to total motile sperm count group V (72.5 ± 17.6 vs. 84.9 ± 14.4, p = 0.011). The normal total motile sperm count group had a higher fertilization rate (84.9 ± 14.4 vs. 81.1 ± 15.8, p = 0.016) and lower miscarriage rate (17.9% vs. 29.5%, p = 0.041) compared to the abnormal total motile sperm count group. The total motile sperm count was the only parameter that demonstrated a predictive value for the formation of high-quality embryos on D2 (OR: 1.18, p = 0.013), formation of high-quality embryos on D3 (OR: 1.12, p = 0.037), formation of blastocysts on D5 (OR: 1.16, p = 0.011), blastocyst expansion grade on D5 (OR: 1.27, p = 0.042), and the odds of miscarriage (OR: 0.52, p < 0.045). The total motile sperm count has a greater predictive value than the WHO 2010 cut-off values for laboratory results and pregnancy outcomes in couples undergoing intracytoplasmic sperm injection as a result of male infertility. © 2016 American Society of Andrology and European Academy of Andrology.

  1. X-ray detection of the symbiotic star AG Draconis

    NASA Technical Reports Server (NTRS)

    Anderson, C. M.; Cassinelli, J. P.; Sanders, W. T.

    1981-01-01

    The detection of the yellow symbiotic star AG Draconis is reported. The star was detected by an imaging proportional counter at a count rate of 0.27 counts/s. The object is an intense source of very soft X-rays, and the X-ray luminosity is estimated to be equal to approximately 10 to the 32nd ergs/s, with a temperature of less than 2,000,000 K. If an interstellar column density of 3 x 10 to the 20th/sq cm is assumed, the emission measure is deduced to be greater than 3 x 10 to the 55th/ cu cm from the X-ray data, and less than 3 x 10 to the 59th/cu cm from the optical data. The observation is discussed in the context of various models of the symbiotic stars.

  2. Making Hawai'i's Kids Count. Issue Paper Number 3.

    ERIC Educational Resources Information Center

    Hawaii Univ., Manoa. Center on the Family.

    This issue paper from Hawai'i Kids Count addresses the issue of teen pregnancy and birth rates. The paper notes that teen pregnancy and birth rates are declining both nationally and in Hawaii and describes key risk factors associated with having a baby before age 20: (1) early school failure; (2) early behavioral problems; (3) family dysfunction;…

  3. Arkansas Kids Count Data Book 1995: A Portrait of Arkansas' Children.

    ERIC Educational Resources Information Center

    Arkansas Advocates for Children and Families, Little Rock.

    This Kids Count report is the third to examine the well-being of Arkansas' children and the first to provide trend information. The statistical report is based on 10 core indicators of well-being: (1) unemployment rate and per capita personal income; (2) federal and state assistance program participation rates; (3) percent of high school students…

  4. Pneumocystis jirovecii colonisation in HIV-positive and HIV-negative subjects in Cameroon.

    PubMed

    Riebold, D; Enoh, D O; Kinge, T N; Akam, W; Bumah, M K; Russow, K; Klammt, S; Loebermann, M; Fritzsche, C; Eyong, J E; Eppel, G; Kundt, G; Hemmer, C J; Reisinger, E C

    2014-06-01

    To determine the prevalence of Pneumocystis pneumonia (PCP), a major opportunistic infection in AIDS patients in Europe and the USA, in Cameroon. Induced sputum samples from 237 patients without pulmonary symptoms (126 HIV-positive and 111 HIV-negative outpatients) treated at a regional hospital in Cameroon were examined for the prevalence of Pneumocystis jirovecii by specific nested polymerase chain reaction (nPCR) and staining methods. CD 4 counts and the history of antiretroviral therapy of the subjects were obtained through the ESOPE database system. Seventy-five of 237 study participants (31.6%) were colonised with Pneumocystis, but none showed active PCP. The Pneumocystis colonisation rate in HIV-positive subjects was more than double that of HIV-negative subjects (42.9% vs. 18.9%, P < 0.001). In the HIV-positive group, the colonisation rate corresponds to the reduction in the CD 4 lymphocyte counts. Subjects with CD 4 counts >500 cells/μl were colonised at a rate of 20.0%, subjects with CD 4 counts between 200 and 500 cells/μl of 42.5%, and subjects with CD 4 counts <200 cells/μl of 57.1%. Colonisation with Pneumocystis in Cameroon seems to be comparable to rates found in Western Europe. Prophylactic and therapeutic measures against Pneumocystis should be taken into account in HIV care in western Africa. © 2014 John Wiley & Sons Ltd.

  5. Differential Die-Away Instrument: Report on Neutron Detector Recovery Performance and Proposed Improvements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goodsell, Alison Victoria; Swinhoe, Martyn Thomas; Henzl, Vladimir

    2014-09-22

    Four helium-3 ( 3He) detector/preamplifier packages (¾”/KM200, DDSI/PDT-A111, DDA/PDT-A111, and DDA/PDT10A) were experimentally tested to determine the deadtime effects at different DT neutron generator output settings. At very high count rates, the ¾”/KM200 package performed best. At high count rates, the ¾”/KM200 and the DDSI/PDT-A111 packages performed very well, with the DDSI/PDT-A111 operating with slightly higher efficiency. All of the packages performed similarly at mid to low count rates. Proposed improvements include using a fast recovery LANL-made dual channel preamplifier, testing smaller diameter 3He tubes, and further investigating quench gases.

  6. Clustering method for counting passengers getting in a bus with single camera

    NASA Astrophysics Data System (ADS)

    Yang, Tao; Zhang, Yanning; Shao, Dapei; Li, Ying

    2010-03-01

    Automatic counting of passengers is very important for both business and security applications. We present a single-camera-based vision system that is able to count passengers in a highly crowded situation at the entrance of a traffic bus. The unique characteristics of the proposed system include, First, a novel feature-point-tracking- and online clustering-based passenger counting framework, which performs much better than those of background-modeling-and foreground-blob-tracking-based methods. Second, a simple and highly accurate clustering algorithm is developed that projects the high-dimensional feature point trajectories into a 2-D feature space by their appearance and disappearance times and counts the number of people through online clustering. Finally, all test video sequences in the experiment are captured from a real traffic bus in Shanghai, China. The results show that the system can process two 320×240 video sequences at a frame rate of 25 fps simultaneously, and can count passengers reliably in various difficult scenarios with complex interaction and occlusion among people. The method achieves high accuracy rates up to 96.5%.

  7. Single photon detection in a waveguide-coupled Ge-on-Si lateral avalanche photodiode.

    PubMed

    Martinez, Nicholas J D; Gehl, Michael; Derose, Christopher T; Starbuck, Andrew L; Pomerene, Andrew T; Lentine, Anthony L; Trotter, Douglas C; Davids, Paul S

    2017-07-10

    We examine gated-Geiger mode operation of an integrated waveguide-coupled Ge-on-Si lateral avalanche photodiode (APD) and demonstrate single photon detection at low dark count for this mode of operation. Our integrated waveguide-coupled APD is fabricated using a selective epitaxial Ge-on-Si growth process resulting in a separate absorption and charge multiplication (SACM) design compatible with our silicon photonics platform. Single photon detection efficiency and dark count rate is measured as a function of temperature in order to understand and optimize performance characteristics in this device. We report single photon detection of 5.27% at 1310 nm and a dark count rate of 534 kHz at 80 K for a Ge-on-Si single photon avalanche diode. Dark count rate is the lowest for a Ge-on-Si single photon detector in this range of temperatures while maintaining competitive detection efficiency. A jitter of 105 ps was measured for this device.

  8. THE LIGHT CURVE OF HERCULES X-1 AS OBSERVED BY THE ROSSI X-RAY TIMING EXPLORER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leahy, D. A.; Igna, Ciprian, E-mail: leahy@ucalgary.ca

    2011-07-20

    Analysis of the light curve of Hercules X-1 using the full set of archival observations of Hercules X-1 by the Rossi X-Ray Timing Explorer/Proportional Counter Array (RXTE/PCA) is reported. The observations cover time periods that Her X-1 is in main high, short high, and low states, and an anomalous low state (ALS). They include over 1.4 Ms of net exposure time. We present 35 day and orbital phase folded light curves of the count rates and softness ratios, showing the range of behaviors of Her X-1 with the high sensitivity of the RXTE/PCA. New phenomena are uncovered and previous phenomenamore » are seen in greater detail. For both main high and short high states, the fraction of time in dips is found to be a function of orbital phase and of 35 day phase. It increases steadily with orbital phase past orbital phase 0.3 and is higher at the start and end of both main high and short high states. It is higher for short high state (62%) than for main high state (28%). The normal low state data and ALS data are compared: the low state count rate is {approx}twice as high as for ALS data. The 2-4 keV to 9-20 keV softness ratio changes smoothly with orbital phase for low states and ALSs, and is indistinguishable between the two, yet very different than for the high states. This supports models for which the cause of the ALS is changed disk geometry that prevents a direct line of sight from neutron star to observer at all 35 day phases.« less

  9. Onsets of Solar Proton Events in Satellite and Ground Level Observations: A Comparison

    NASA Astrophysics Data System (ADS)

    He, Jing; Rodriguez, Juan V.

    2018-03-01

    The early detection of solar proton event onsets is essential for protecting humans and electronics in space, as well as passengers and crew at aviation altitudes. Two commonly compared methods for observing solar proton events that are sufficiently large and energetic to be detected on the ground through the creation of secondary radiation—known as ground level enhancements (GLEs)—are (1) a network of ground-based neutron monitors (NMs) and (2) satellite-based particle detectors. Until recently, owing to the different time resolution of the two data sets, it has not been feasible to compare these two types of observations using the same detection algorithm. This paper presents a comparison between the two observational platforms using newly processed >100 MeV 1 min count rates and fluxes from National Oceanic and Atmospheric Administration's Geostationary Operational Environmental Satellite (GOES) 8-12 satellites, and 1 min count rates from the Neutron Monitor Database. We applied the same detection algorithm to each data set (tuned to the different background noise levels of the instrument types). Seventeen SPEs with GLEs were studied: GLEs 55-70 from Solar Cycle 23 and GLE 71 from Solar Cycle 24. The median difference in the event detection times by GOES and NM data is 0 min, indicating no innate benefit in time of either system. The 10th, 25th, 75th, and 90th percentiles of the onset time differences (GOES minus NMs) are -7.2 min, -1.5 min, 2.5 min, and 4.2 min, respectively. This is in contrast to previous studies in which NM detections led GOES by 8 to 52 min without accounting for different alert protocols.

  10. The ROSAT All-Sky Survey view of the Large Magellanic Cloud (LMC)

    NASA Technical Reports Server (NTRS)

    Pietsch, W.; Denner, K.; Kahabka, P.; Pakull, M.; Schaeidt, S.

    1996-01-01

    During the Rosat all sky survey, centered on the Large Magellanic Cloud (LMC), 516 X-ray sources were detected. The field was covered from July 1990 to January 1991. The X-ray parameters of the sources, involving position, count rates, hardness ratios, extent, and time variability during the observations, are discussed. Identifications with objects from optical, radio and infrared wavelength allow the LMC candidates to be separated from the foreground stars and the background objects.

  11. Prevalence and quantification of thermophilic Campylobacter spp. in Italian retail poultry meat: Analysis of influencing factors.

    PubMed

    Stella, Simone; Soncini, Gabriella; Ziino, Graziella; Panebianco, Antonio; Pedonese, Francesca; Nuvoloni, Roberta; Di Giannatale, Elisabetta; Colavita, Giampaolo; Alberghini, Leonardo; Giaccone, Valerio

    2017-04-01

    Retail poultry meat is a crucial vehicle for consumers' exposure to Campylobacters, but no official controls are currently applied in Italy. The aim of this study was the evaluation of Campylobacter contamination of a wide range of poultry meats marketed in Italy. N. 472 chicken and turkey meat samples (sectioned meats, offal, meat preparations and products) were taken from slaughterhouses, deboning plants and different retailers and submitted to detection/enumeration of Campylobacter spp. The isolates were identified by phenotypic and biomolecular techniques. Campylobacter spp. was detected in 34.1% of the samples, with general low counts. Higher values were observed in offal (especially liver) and sectioned meats, with significantly higher rates in skin-on samples (86.8% vs 32.7%). Minced meat preparations showed lower prevalence (22.4% vs 58.3%) and counts than whole pieces. Decreasing rates were observed among slaughterhouses (80%), deboning plants (49%), butcher's shops (37%) and large scale retailers (25%). Sectioned chicken meats were significantly more contaminated than turkey meats. Almost all the isolates were identified as C. jejuni or C. coli, with similar prevalences (18.4% and 20.5%, respectively); C. jejuni was predominant only in samples from slaughterhouses/deboning plants. For setting future control programs, meat typology should be considered the main critical factor. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Establishing a gold standard for manual cough counting: video versus digital audio recordings

    PubMed Central

    Smith, Jaclyn A; Earis, John E; Woodcock, Ashley A

    2006-01-01

    Background Manual cough counting is time-consuming and laborious; however it is the standard to which automated cough monitoring devices must be compared. We have compared manual cough counting from video recordings with manual cough counting from digital audio recordings. Methods We studied 8 patients with chronic cough, overnight in laboratory conditions (diagnoses were 5 asthma, 1 rhinitis, 1 gastro-oesophageal reflux disease and 1 idiopathic cough). Coughs were recorded simultaneously using a video camera with infrared lighting and digital sound recording. The numbers of coughs in each 8 hour recording were counted manually, by a trained observer, in real time from the video recordings and using audio-editing software from the digital sound recordings. Results The median cough frequency was 17.8 (IQR 5.9–28.7) cough sounds per hour in the video recordings and 17.7 (6.0–29.4) coughs per hour in the digital sound recordings. There was excellent agreement between the video and digital audio cough rates; mean difference of -0.3 coughs per hour (SD ± 0.6), 95% limits of agreement -1.5 to +0.9 coughs per hour. Video recordings had poorer sound quality even in controlled conditions and can only be analysed in real time (8 hours per recording). Digital sound recordings required 2–4 hours of analysis per recording. Conclusion Manual counting of cough sounds from digital audio recordings has excellent agreement with simultaneous video recordings in laboratory conditions. We suggest that ambulatory digital audio recording is therefore ideal for validating future cough monitoring devices, as this as this can be performed in the patients own environment. PMID:16887019

  13. Estimation of DMFT, Salivary Streptococcus Mutans Count, Flow Rate, Ph, and Salivary Total Calcium Content in Pregnant and Non-Pregnant Women: A Prospective Study.

    PubMed

    Kamate, Wasim Ismail; Vibhute, Nupura Aniket; Baad, Rajendra Krishna

    2017-04-01

    Pregnancy, a period from conception till birth, causes changes in the functioning of the human body as a whole and specifically in the oral cavity that may favour the emergence of dental caries. Many studies have shown pregnant women at increased risk for dental caries, however, specific salivary caries risk factors and the particular period of pregnancy at heightened risk for dental caries are yet to be explored and give a scope of further research in this area. The aim of the present study was to assess the severity of dental caries in pregnant women compared to non-pregnant women by evaluating parameters like Decayed, Missing, Filled Teeth (DMFT) index, salivary Streptococcus mutans count, flow rate, pH and total calcium content. A total of 50 first time pregnant women in the first trimester were followed during their second trimester, third trimester and postpartum period for the evaluation of DMFT by World Health Organization (WHO) scoring criteria, salivary flow rate by drooling method, salivary pH by pH meter, salivary total calcium content by bioassay test kit and salivary Streptococcus mutans count by semiautomatic counting of colonies grown on Mitis Salivarius (MS) agar supplemented by 0.2U/ml of bacitracin and 10% sucrose. The observations of pregnant women were then compared with same parameters evaluated in the 50 non-pregnant women. Paired t-test and Wilcoxon sign rank test were performed to assess the association between the study parameters. Evaluation of different caries risk factors between pregnant and non-pregnant women clearly showed that pregnant women were at a higher risk for dental caries. Comparison of caries risk parameters during the three trimesters and postpartum period showed that the salivary Streptococcus mutans count had significantly increased in the second trimester , third trimester and postpartum period while the mean pH and mean salivary total calcium content decreased in the third trimester and postpartum period. These changes reflected on the DMFT score which increased in the third trimester and postpartum period. The results of this study suggest that there is a definite correlation between pregnancy and dental caries. We conclude that the third trimester and postpartum period of pregnancy are the periods during which the pregnant women are at a higher risk for development of dental caries.

  14. The extreme solar cosmic ray particle event on 20 January 2005 and its influence on the radiation dose rate at aircraft altitude.

    PubMed

    Bütikofer, R; Flückiger, E O; Desorgher, L; Moser, M R

    2008-03-01

    In January 2005 toward the end of solar activity cycle 23 the Sun was very active. Between 15 and 20 January 2005, the solar active region NOAA AR 10720 produced five powerful solar flares. In association with this major solar activity several pronounced variations in the ground-level cosmic ray intensity were observed. The fifth of these flares (X7.1) produced energetic solar cosmic rays that caused a giant increase in the count rates of the ground-based cosmic ray detectors (neutron monitors). At southern polar neutron monitor stations the increase of the count rate reached several thousand percent. From the recordings of the worldwide network of neutron monitors, we determined the characteristics of the solar particle flux near Earth. In the initial phase of the event, the solar cosmic ray flux near Earth was extremely anisotropic. The energy spectrum of the solar cosmic rays was fairly soft during the main and the decay phase. We investigated also the flux of different secondary particle species in the atmosphere and the radiation dosage at flight altitude. Our analysis shows a maximum increment of the effective dose rate due to solar cosmic rays in the south polar region around 70 degrees S and 130 degrees E at flight altitude of almost three orders of magnitude.

  15. Low cost digital electronics for isotope analysis with microcalorimeters - final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    W. Hennig

    2006-09-11

    The overall goal of the Phase I research was to demonstrate that the digital readout electronics and filter algorithms developed by XIA for use with HPGe detectors can be adapted to high precision, cryogenic gamma detectors (microcalorimeters) and not only match the current state of the art in terms of energy resolution, but do so at a significantly reduced cost. This would make it economically feasible to instrument large arrays of microcalorimeters and would also allow automation of the setup, calibration and operation of large numbers of channels through software. We expected, and have demonstrated, that this approach would furthermore » allow much higher count rates than the optimum filter algorithms currently used. In particular, in measurements with a microcalorimeter at LLNL, the adapted Pixie-16 spectrometer achieved an energy resolution of 0.062%, significantly better than the targeted resolution of 0.1% in the Phase I proposal and easily matching resolutions obtained with LLNL readout electronics and optimum filtering (0.066%). The theoretical maximum output count rate for the filter settings used to achieve this resolution is about 120cps. If the filter is adjusted for maximum throughput with an energy resolution of 0.1% or better, rates of 260cps are possible. This is 20-50 times higher than the maximum count rates of about 5cps with optimum filters for this detector. While microcalorimeter measurements were limited to count rates of ~1.3cps due to the strength of available sources, pulser measurements demonstrated that measured energy resolutions were independent of counting rate to output counting rates well in excess of 200cps or more.. We also developed a preliminary hardware design of a spectrometer module, consisting of a digital processing core and several input options that can be implemented on daughter boards. Depending upon the daughter board, the total parts cost per channel ranged between $12 and $27, resulting in projected product prices of $80 to $160 per channel. This demonstrates that a price of $100 per channel is economically very feasible for large microcalorimeter arrays.« less

  16. Digital scale converter

    DOEpatents

    Upton, Richard G.

    1978-01-01

    A digital scale converter is provided for binary coded decimal (BCD) conversion. The converter may be programmed to convert a BCD value of a first scale to the equivalent value of a second scale according to a known ratio. The value to be converted is loaded into a first BCD counter and counted down to zero while a second BCD counter registers counts from zero or an offset value depending upon the conversion. Programmable rate multipliers are used to generate pulses at selected rates to the counters for the proper conversion ratio. The value present in the second counter at the time the first counter is counted to the zero count is the equivalent value of the second scale. This value may be read out and displayed on a conventional seven-segment digital display.

  17. Characterization of the Geosynchronous Plasma Environment for the SENSER/RROE Optical Instrument

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Woodroffe, Jesse Richard

    2016-11-08

    In this report, we summarize available research in order to characterize expected rates of particle incidence on the SENSER/RROE optical instrument. We first investigate the “normal” background levels using data from statistical studies of spacecraft in geosynchronous orbit and empirical models. We then consider “worst case” scenarios based on event studies in which extreme fluxes have been observed. We use these data to define “maximum” rates of particle incidence. We then consider how incident particles will actually produce counts in the instrument by considering the effects of screening by the instrument housing and the possibility of direct particle access tomore » the housing, with rates for both primary access and secondary electron generation.« less

  18. Atmospheric Effects on Cosmic Ray Air Showers Observed with HAWC

    NASA Astrophysics Data System (ADS)

    Young, Steven

    2014-01-01

    The High Altitude Water Cherenkov Gamma Ray detector (HAWC), currently under construction on the Sierra Negra volcano near Puebla, Mexico, can be used to study solar physics with its scaler data acquisition system. Increases in the scaler rates are used to observe GeV cosmic rays from solar flares while decreases in the rates show the heliospheric disturbances associated with coronal mass ejections. However, weather conditions and height-dependent state variables such as pressure and temperature affect the production of extensive particle air showers that can be detected by the scaler system. To see if these atmospheric effects can be removed, we obtained local weather data from the Global Data Assimilation System (GDAS) and the local weather station at HAWC. The scaler pulse rates were then correlated to the pressure and temperature. We present data from a Forbush decrease observed by HAWC following a significant coronal mass ejection in April 2013, and describe our efforts to remove atmospheric variations from the scaler counts. This work was partially supported by the National Science Foundation’s REU program through NSF Award AST-1004881 to the University of Wisconsin-Madison.

  19. Synthesis and assessment of fertility-regulating potential of 2-(2''-chloroacetamidobenzyl)-3-(3'-indolyl) quinoline in adult rats as a male contraceptive agent.

    PubMed

    Bhowal, Sujit K; Lala, Sanchita; Hazra, Abhijit; Paira, Priyankar; Banerjee, Sukdeb; Mondal, Nirup B; Chakraborty, Smritinath

    2008-03-01

    The purpose of this study was to investigate the fertility-regulating potential of the compound 2-(2''-chloroacetamidobenzyl)-3-(3'-indolyl) quinoline in male rats. Rats of proven fertility were treated with the compound by oral gavage for 1 to 8 consecutive weeks. Functional fertility, testicular, epididymal and seminal vesicular weight, epididymal sperm count and spermatogenesis were quantitated. Reproductive hormones and some biochemical parameters were measured. Functional fertility was reduced significantly as revealed by a fall in fertility and pregnancy rate. The weight of the reproductive organs was reduced significantly. A reduction of sperm count and number of different types of testicular cells was observed. The treatment with the compound resulted in decline of testosterone and an increase of FSH hormone levels. The compound effectively reduced testicular protein, glycogen and epididymal glyceryl phosphorylcholine. Increase in testicular alkaline phosphatase and cholesterol was also observed. Fertility and other effects were regained gradually after cessation of treatment. The results revealed from the study indicate that the compound has reversible antifertility activity and can be explored as male contraceptive agent.

  20. Partial bisulfite conversion for unique template sequencing.

    PubMed

    Kumar, Vijay; Rosenbaum, Julie; Wang, Zihua; Forcier, Talitha; Ronemus, Michael; Wigler, Michael; Levy, Dan

    2018-01-25

    We introduce a new protocol, mutational sequencing or muSeq, which uses sodium bisulfite to randomly deaminate unmethylated cytosines at a fixed and tunable rate. The muSeq protocol marks each initial template molecule with a unique mutation signature that is present in every copy of the template, and in every fragmented copy of a copy. In the sequenced read data, this signature is observed as a unique pattern of C-to-T or G-to-A nucleotide conversions. Clustering reads with the same conversion pattern enables accurate count and long-range assembly of initial template molecules from short-read sequence data. We explore count and low-error sequencing by profiling 135 000 restriction fragments in a PstI representation, demonstrating that muSeq improves copy number inference and significantly reduces sporadic sequencer error. We explore long-range assembly in the context of cDNA, generating contiguous transcript clusters greater than 3,000 bp in length. The muSeq assemblies reveal transcriptional diversity not observable from short-read data alone. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  1. Association of Mycoplasma pneumoniae infection with increased risk of asthma in children.

    PubMed

    Yin, Sha-Sha; Ma, Feng-Lian; Gao, Xing

    2017-05-01

    The present study was conducted to investigate the relationship between Mycoplasma pneumoniae (MP) infection and the risk of asthma among children by detecting the rate of MP immunoglobulin M (MP-IgM) and the eosinophil (EOS) count. A total of 139 asthmatic children were enrolled as the case group and assigned into three groups: Group A (aged <3 years, n=42), group B (aged 3-8 years, n=45) and group C (aged >8 years, n=52). Additionally, 115 healthy children were enrolled in the control group. Enzyme-linked immunosorbent assay was used to measure the MP-IgM-positive rate. EOS count was detected in the experimental and control groups by using a hemocytometer analyzer. A meta-analysis was performed by using the Comprehensive Meta-Analysis version 2.0 software. The positive rates of the MP-IgM and EOS count in the experimental group were significantly higher than those in control group (both P<0.001). Furthermore, the asthmatic children in group C had a higher MP-IgM-positive rate and EOS count as compared to those in groups A and B, respectively (all P<0.05). Results from groups A and B were not statistically significant (all P>0.05). The meta-analysis further confirmed that asthmatic children had a higher MP-IgM-positive rate as compared to the healthy controls (P<0.001). Age-stratified analysis revealed that the MP-IgM-positive rate in asthmatic children aged ≥8 and <8 years was significantly higher than that in the healthy controls (P=0.003 and P<0.001). Asthmatic children had a higher MP-IgM-positive rate and EOS count as compared with controls, suggesting that the MP infection may be closely associated with the risk of asthma. Additionally, the positive rate of MP-IgM may indicate an important biological marker in predicting the development of asthma.

  2. High count-rate study of two TES x-ray microcalorimeters with different transition temperatures

    NASA Astrophysics Data System (ADS)

    Lee, Sang-Jun; Adams, Joseph S.; Bandler, Simon R.; Betancourt-Martinez, Gabriele L.; Chervenak, James A.; Eckart, Megan E.; Finkbeiner, Fred M.; Kelley, Richard L.; Kilbourne, Caroline A.; Porter, Frederick S.; Sadleir, John E.; Smith, Stephen J.; Wassell, Edward J.

    2017-10-01

    We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures (T c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T cs had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.3 eV at 6 keV from lower and higher T c devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the so-called event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96% throughput for 6 keV x-rays of 1025 Hz per pixel with the higher T c (faster) device, and 5.8 eV FWHM with 97% throughput with the lower T c (slower) device at 722 Hz.

  3. Investigation of FPGA-Based Real-Time Adaptive Digital Pulse Shaping for High-Count-Rate Applications

    NASA Astrophysics Data System (ADS)

    Saxena, Shefali; Hawari, Ayman I.

    2017-07-01

    Digital signal processing techniques have been widely used in radiation spectrometry to provide improved stability and performance with compact physical size over the traditional analog signal processing. In this paper, field-programmable gate array (FPGA)-based adaptive digital pulse shaping techniques are investigated for real-time signal processing. National Instruments (NI) NI 5761 14-bit, 250-MS/s adaptor module is used for digitizing high-purity germanium (HPGe) detector's preamplifier pulses. Digital pulse processing algorithms are implemented on the NI PXIe-7975R reconfigurable FPGA (Kintex-7) using the LabVIEW FPGA module. Based on the time separation between successive input pulses, the adaptive shaping algorithm selects the optimum shaping parameters (rise time and flattop time of trapezoid-shaping filter) for each incoming signal. A digital Sallen-Key low-pass filter is implemented to enhance signal-to-noise ratio and reduce baseline drifting in trapezoid shaping. A recursive trapezoid-shaping filter algorithm is employed for pole-zero compensation of exponentially decayed (with two-decay constants) preamplifier pulses of an HPGe detector. It allows extraction of pulse height information at the beginning of each pulse, thereby reducing the pulse pileup and increasing throughput. The algorithms for RC-CR2 timing filter, baseline restoration, pile-up rejection, and pulse height determination are digitally implemented for radiation spectroscopy. Traditionally, at high-count-rate conditions, a shorter shaping time is preferred to achieve high throughput, which deteriorates energy resolution. In this paper, experimental results are presented for varying count-rate and pulse shaping conditions. Using adaptive shaping, increased throughput is accepted while preserving the energy resolution observed using the longer shaping times.

  4. The Herschel-ATLAS: Extragalatic Number Counts from 250 to 500 Microns

    NASA Technical Reports Server (NTRS)

    Clements, D. L.; Rigby, E.; Maddox, S.; Dunne, L.; Mortier, A.; Amblard, A.; Auld, R.; Bonfield, D.; Cooray, A.; Dariush, A.; hide

    2010-01-01

    Aims.The Herschel-ATLAS survey (H-ATLAS) will be the largest area survey to be undertaken by the Herschel Space Observatory. It will cover 550 sq. deg. of extragalactic sky at wavelengths of 100, 160, 250, 350 and 500 microns when completed, reaching flux limits (50-) from 32 to 145mJy. We here present galaxy number counts obtained for SPIRE observations of the first -14 sq. deg. observed at 250, 350 and 500 m. Methods. Number counts are a fundamental tool in constraining models of galaxy evolution. We use source catalogs extracted from the H-ATLAS maps as the basis for such an analysis. Correction factors for completeness and flux boosting are derived by applying our extraction method to model catalogs and then applied to the raw observational counts. Results. We find a steep rise in the number counts at flux levels of 100-200mJy in all three SPIRE bands, consistent with results from BLAST. The counts are compared to a range of galaxy evolution models. None of the current models is an ideal fit to the data but all ascribe the steep rise to a population of luminous, rapidly evolving dusty galaxies at moderate to high redshift.

  5. Assessment of operating room airflow using air particle counts and direct observation of door openings.

    PubMed

    Teter, Jonathan; Guajardo, Isabella; Al-Rammah, Tamrah; Rosson, Gedge; Perl, Trish M; Manahan, Michele

    2017-05-01

    The role of the operating room (OR) environment has been thought to contribute to surgical site infection rates. The quality of OR air, disruption of airflow, and other factors may increase contamination risks. We measured air particulate counts (APCs) to determine if they increased in relation to traffic, door opening, and other common activities. During 1 week, we recorded APCs in 5-minute intervals and movement of health care workers. Trained observers recorded information about traffic, door openings, job title of the opener, and the reason for opening. At least 1 OR door was open during 47% of all readings. There were 13.4 door openings per hour during cases. Door opening rates ranged from 0.19-0.28 per minute. During this time, a total of 660 air measurements were obtained. The mean APCs were 9,238 particles (95% confidence interval [CI], 5,494- 12,982) at baseline and 14,292 particles (95% CI, 12,382-16,201) during surgery. Overall APCs increased 13% when either door was opened (P < .15). Larger particles that correlated to bacterial size were elevated significantly (P < .001) on door opening. We observed numerous instances of verbal communication and equipment movement. Improving efficiency of communication and equipment can aid in reduction of traffic. Further study is needed to examine links between microbiologic sampling, outcome data, and particulate matter to enable study of risk factors and effects of personnel movement. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  6. Effects of Point Count Duration, Time-of-Day, and Aural Stimuli on Detectability of Migratory and Resident Bird Species in Quintana Roo, Mexico

    Treesearch

    James F. Lynch

    1995-01-01

    Effects of count duration, time-of-day, and aural stimuli were studied in a series of unlimited-radius point counts conducted during winter in Quintana Roo, Mexico. The rate at which new species were detected was approximately three times higher during the first 5 minutes of each 15- minute count than in the final 5 minutes. The number of individuals and species...

  7. Fluorescence decay data analysis correcting for detector pulse pile-up at very high count rates

    NASA Astrophysics Data System (ADS)

    Patting, Matthias; Reisch, Paja; Sackrow, Marcus; Dowler, Rhys; Koenig, Marcelle; Wahl, Michael

    2018-03-01

    Using time-correlated single photon counting for the purpose of fluorescence lifetime measurements is usually limited in speed due to pile-up. With modern instrumentation, this limitation can be lifted significantly, but some artifacts due to frequent merging of closely spaced detector pulses (detector pulse pile-up) remain an issue to be addressed. We propose a data analysis method correcting for this type of artifact and the resulting systematic errors. It physically models the photon losses due to detector pulse pile-up and incorporates the loss in the decay fit model employed to obtain fluorescence lifetimes and relative amplitudes of the decay components. Comparison of results with and without this correction shows a significant reduction of systematic errors at count rates approaching the excitation rate. This allows quantitatively accurate fluorescence lifetime imaging at very high frame rates.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Church, J; Slaughter, D; Norman, E

    Error rates in a cargo screening system such as the Nuclear Car Wash [1-7] depend on the standard deviation of the background radiation count rate. Because the Nuclear Car Wash is an active interrogation technique, the radiation signal for fissile material must be detected above a background count rate consisting of cosmic, ambient, and neutron-activated radiations. It was suggested previously [1,6] that the Corresponding negative repercussions for the sensitivity of the system were shown. Therefore, to assure the most accurate estimation of the variation, experiments have been performed to quantify components of the actual variance in the background count rate,more » including variations in generator power, irradiation time, and container contents. The background variance is determined by these experiments to be a factor of 2 smaller than values assumed in previous analyses, resulting in substantially improved projections of system performance for the Nuclear Car Wash.« less

  9. Mount Rainier National Park and Olympic National Park Elk Monitoring Program Annual Report 2010

    USGS Publications Warehouse

    Griffin, Paul; Happe, Patricia J.; Jenkins, Kurt J.; Reid, Mason; Vales, David J.; Moeller, Barbara J.; Tirhi, Michelle; McCorquodale, Scott; Miller, Pat

    2010-01-01

    Fiscal year 2010 was the third year of gathering data needed for protocol development while simultaneously implementing what is expected to be the elk monitoring protocol at Mount Rainier (MORA) and Olympic (OLYM) national parks in the North Coast and Cascades Network (NCCN). Elk monitoring in these large wilderness parks relies on aerial surveys from a helicopter. Summer surveys are planned for both parks and are intended to provide quantitative estimates of abundance, sex and age composition, and distribution of migratory elk in high elevation trend count areas. Spring surveys are planned at Olympic National Park and are intended to provide quantitative estimates of abundance of resident and migratory elk on low-elevation winter ranges within surveyed trend count areas. An unknown number of elk is not detected during surveys. The protocol under development aims to estimate the number of missed elk by applying a model that accounts for detection bias. Detection bias in elk surveys in MORA will be estimated using a double-observer sightability model that was developed based on data from surveys conducted in 2008-2010. The model was developed using elk that were previously equipped with radio collars by cooperating tribes. That model is currently in peer review. At the onset of protocol development in OLYM there were no existing radio- collars on elk. Consequently double-observer sightability models have not yet been developed for elk surveys in OLYM; the majority of the effort in OLYM has been focused on capturing and radio collaring elk to permit the development of sightability models for application in OLYM. As a result, no estimates of abundance or composition are included in this annual report, only raw counts of the numbers of elk seen in surveys. At MORA each of the two trend count areas (North Rainier herd, and South Rainier herd) were surveyed twice. 290 and 380 elk were counted on the two replicates in the North Rainier herd, and 621 and 327 elk counted on the two replicate South Rainier counts. At Olympic National Park, each of three spring trend count areas was surveyed once in March 2010. 27 elk were observed in the South Fork Hoh trend count area, 137 elk were observed in the Hoh trend count area, and 131 elk were observed in the Queets trend count area. In September 2010, 18 elk were captured and fitted with radio collars as part of a contracted animal capture, eradication and tagging of animals (ACETA) operation. These animals will be available to contribute double-observer sightability data in future spring and summer surveys. There were no summer surveys for elk in OLYM in 2010.

  10. Pile-up correction algorithm based on successive integration for high count rate medical imaging and radiation spectroscopy

    NASA Astrophysics Data System (ADS)

    Mohammadian-Behbahani, Mohammad-Reza; Saramad, Shahyar

    2018-07-01

    In high count rate radiation spectroscopy and imaging, detector output pulses tend to pile up due to high interaction rate of the particles with the detector. Pile-up effects can lead to a severe distortion of the energy and timing information. Pile-up events are conventionally prevented or rejected by both analog and digital electronics. However, for decreasing the exposure times in medical imaging applications, it is important to maintain the pulses and extract their true information by pile-up correction methods. The single-event reconstruction method is a relatively new model-based approach for recovering the pulses one-by-one using a fitting procedure, for which a fast fitting algorithm is a prerequisite. This article proposes a fast non-iterative algorithm based on successive integration which fits the bi-exponential model to experimental data. After optimizing the method, the energy spectra, energy resolution and peak-to-peak count ratios are calculated for different counting rates using the proposed algorithm as well as the rejection method for comparison. The obtained results prove the effectiveness of the proposed method as a pile-up processing scheme designed for spectroscopic and medical radiation detection applications.

  11. A mercuric iodide detector system for X-ray astronomy. II - Results from flight tests of a balloon borne instrument

    NASA Technical Reports Server (NTRS)

    Vallerga, J. V.; Vanderspek, R. K.; Ricker, G. R.

    1983-01-01

    To establish the expected sensitivity of a new hard X-ray telescope design, described by Ricker et al., an experiment was conducted to measure the background counting rate at balloon altitudes (40 km) of mercuric iodide, a room temperature solid state X-ray detector. The prototype detector consisted of two thin mercuric iodide (HgI2) detectors surrounded by a large bismuth germanate scintillator operated in anticoincidence. The bismuth germanate shield vetoed most of the background counting rate induced by atmospheric gamma-rays, neutrons and cosmic rays. A balloon-borne gondola containing a prototype detector assembly was designed, constructed and flown twice in the spring of 1982 from Palestine, TX. The second flight of this instrument established a differential background counting rate of 4.2 + or - 0.7 x 10 to the -5th counts/s sq cm keV over the energy range of 40-80 keV. This measurement was within 50 percent of the predicted value. The measured rate is about 5 times lower than previously achieved in shielded NaI/CsI or Ge systems operating in the same energy range.

  12. The Money/Counting Kit. The Prospectus Series, Paper No. 6.

    ERIC Educational Resources Information Center

    Musumeci, Judith

    The Money/Counting Kit for Handicapped Children and Youth, frees the teacher from lessons in money and counting concepts and enables a student to learn at his own rate with immediate feedback from activity cards, name cards, thermoformed coin cards (optional), and self-instructional booklets. The activity cards, which may be used individually or…

  13. Development of a Body Shield for Small Animal PET System to Reduce Random and Scatter Coincidences

    NASA Astrophysics Data System (ADS)

    Wada, Yasuhiro; Yamamoto, Seiichi; Watanabe, Yasuyoshi

    2015-02-01

    For small animal positron emission tomography (PET) research using high radioactivity, such as dynamic studies, the resulting high random coincidence rate of the system degrades image quality. The random coincidence rate is increased not only by the gamma photons from inside the axial-field-of-view (axial-FOV) of the PET system but also by those from outside the axial-FOV. For brain imaging in small animal studies, significant interference is observed from gamma photons emitted from the body. Single gamma photons from the body enter the axial-FOV and increase the random and scatter coincidences. Shielding against the gamma photons from outside the axial-FOV would improve the image quality. For this purpose, we developed a body shield for a small animal PET system, the microPET Primate 4-ring system, and evaluated its performance. The body shield is made of 9-mm-thick lead and it surrounds most of a rat's body. We evaluated the effectiveness of the body shield using a head phantom and a body phantom with a radioactivity concentration ratio of 1:2 and a maximum total activity of approximately 250 MBq. The random coincidence rate was dramatically decreased to 1/10, and the noise equivalent count rate (NECR) was increased 6 times with an activity of 7 MBq in the head phantom. The true count rate was increased to 35% due to the decrease in system deadtime. The average scatter fraction was decreased to 1/2.5 with the body shield. Count rate measurements of rat were also conducted with an injection activity of approximately 25 MBq of [C-11]N,N-dimethyl-2-(2-amino-4-cyanophenylthio) benzylamine ([C-11]DASB) and approximately 70 and 310 MBq of 2-deoxy-2-(F-18)fluoro-D-glucose ([F-18]FDG). Using the body shield, [F-18]FDG images of rats were improved by increasing the amount of radioactivity injected. The body shield designed for small animal PET systems is a promising tool for improving image quality and quantitation accuracy in small animal molecular imaging research.

  14. Probing the water distribution in porous model sands with two immiscible fluids: A nuclear magnetic resonance micro-imaging study

    NASA Astrophysics Data System (ADS)

    Lee, Bum Han; Lee, Sung Keun

    2017-10-01

    The effect of the structural heterogeneity of porous networks on the water distribution in porous media, initially saturated with immiscible fluid followed by increasing durations of water injection, remains one of the important problems in hydrology. The relationship among convergence rates (i.e., the rate of fluid saturation with varying injection time) and the macroscopic properties and structural parameters of porous media have been anticipated. Here, we used nuclear magnetic resonance (NMR) micro-imaging to obtain images (down to ∼50 μm resolution) of the distribution of water injected for varying durations into porous networks that were initially saturated with silicone oil. We then established the relationships among the convergence rates, structural parameters, and transport properties of porous networks. The volume fraction of the water phase increases as the water injection duration increases. The 3D images of the water distributions for silica gel samples are similar to those of the glass bead samples. The changes in water saturation (and the accompanying removal of silicone oil) and the variations in the volume fraction, specific surface area, and cube-counting fractal dimension of the water phase fit well with the single-exponential recovery function { f (t) = a [ 1 -exp (- λt) ] } . The asymptotic values (a, i.e., saturated value) of the properties of the volume fraction, specific surface area, and cube-counting fractal dimension of the glass bead samples were greater than those for the silica gel samples primarily because of the intrinsic differences in the porous networks and local distribution of the pore size and connectivity. The convergence rates of all of the properties are inversely proportional to the entropy length and permeability. Despite limitations of the current study, such as insufficient resolution and uncertainty for the estimated parameters due to sparsely selected short injection times, the observed trends highlight the first analyses of the cube-counting fractal dimension (and other structural properties) and convergence rates in porous networks consisting of two fluid components. These results indicate that the convergence rates correlate with the geometric factor that characterizes the porous networks and transport property of the porous networks.

  15. Maximum likelihood positioning and energy correction for scintillation detectors

    NASA Astrophysics Data System (ADS)

    Lerche, Christoph W.; Salomon, André; Goldschmidt, Benjamin; Lodomez, Sarah; Weissler, Björn; Solf, Torsten

    2016-02-01

    An algorithm for determining the crystal pixel and the gamma ray energy with scintillation detectors for PET is presented. The algorithm uses Likelihood Maximisation (ML) and therefore is inherently robust to missing data caused by defect or paralysed photo detector pixels. We tested the algorithm on a highly integrated MRI compatible small animal PET insert. The scintillation detector blocks of the PET gantry were built with the newly developed digital Silicon Photomultiplier (SiPM) technology from Philips Digital Photon Counting and LYSO pixel arrays with a pitch of 1 mm and length of 12 mm. Light sharing was used to readout the scintillation light from the 30× 30 scintillator pixel array with an 8× 8 SiPM array. For the performance evaluation of the proposed algorithm, we measured the scanner’s spatial resolution, energy resolution, singles and prompt count rate performance, and image noise. These values were compared to corresponding values obtained with Center of Gravity (CoG) based positioning methods for different scintillation light trigger thresholds and also for different energy windows. While all positioning algorithms showed similar spatial resolution, a clear advantage for the ML method was observed when comparing the PET scanner’s overall single and prompt detection efficiency, image noise, and energy resolution to the CoG based methods. Further, ML positioning reduces the dependence of image quality on scanner configuration parameters and was the only method that allowed achieving highest energy resolution, count rate performance and spatial resolution at the same time.

  16. Quality assessment and improvement of "Unsatisfactory" liquid-based cervicovaginal papanicolaou smears.

    PubMed

    Mirzamani, Neda; Chau, Karen; Rafael, Oana; Shergill, Uday; Sajjan, Sujata; Sumskaya, Irina; Gimenez, Cecilia; Klein, Melissa; Das, Kasturi

    2017-10-01

    The quality of cervicovaginal smears determines the success of cytology in screening programs for cervical cancer. Bethesda 2014 revisited the adequacy criteria for atrophic smears and redefined the squamous cell count in the "unsatisfactory" category. In this study, we evaluated the smear quality of Thinprep liquid-based cervicovaginal Papanicolaou cytology slides (TPS) that were previously deemed unsatisfactory, to determine reasons for such categorization. In addition, we attempted to establish the impact of the new adequacy criteria on the rate and management of unsatisfactory diagnosis. About 234 unsatisfactory TPS were examined. The reasons for unsatisfactory were noted. The number of squamous cells was recounted, as per the new Bethesda criteria, in borderline adequacy cases that showed an atrophic pattern. The leading cause for unsatisfactory TPS was lubricating gel, followed by blood, as observed in older and younger age groups, respectively (Figure 1). Eleven borderline cases were reclassified as "satisfactory" using the new Bethesda cell count, with 27% above 60 years of age. About 82% of these borderline cases were negative for intraepithelial lesion or malignancy on repeat testing. There was no difference of management or change in rate of unsatisfactory when patients above 60 were reclassified into the satisfactory category using the new Bethesda count. However, a larger study is needed to evaluate whether the new recommendation for minimum cellularity can be implemented in patients above a certain age cut-off. The study highlights the need for improvement in collection practices and education of practitioners. © 2017 Wiley Periodicals, Inc.

  17. Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

    DOE PAGES

    Lockhart, M.; Henzlova, D.; Croft, S.; ...

    2017-09-20

    Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less

  18. Experimental evaluation of the extended Dytlewski-style dead time correction formalism for neutron multiplicity counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lockhart, M.; Henzlova, D.; Croft, S.

    Over the past few decades, neutron multiplicity counting has played an integral role in Special Nuclear Material (SNM) characterization pertaining to nuclear safeguards. Current neutron multiplicity analysis techniques use singles, doubles, and triples count rates because a methodology to extract and dead time correct higher order count rates (i.e. quads and pents) was not fully developed. This limitation is overcome by the recent extension of a popular dead time correction method developed by Dytlewski. This extended dead time correction algorithm, named Dytlewski-Croft-Favalli (DCF), is detailed in reference Croft and Favalli (2017), which gives an extensive explanation of the theory andmore » implications of this new development. Dead time corrected results can then be used to assay SNM by inverting a set of extended point model equations which as well have only recently been formulated. Here, we discuss and present the experimental evaluation of practical feasibility of the DCF dead time correction algorithm to demonstrate its performance and applicability in nuclear safeguards applications. In order to test the validity and effectiveness of the dead time correction for quads and pents, 252Cf and SNM sources were measured in high efficiency neutron multiplicity counters at the Los Alamos National Laboratory (LANL) and the count rates were extracted up to the fifth order and corrected for dead time. To assess the DCF dead time correction, the corrected data is compared to traditional dead time correction treatment within INCC. In conclusion, the DCF dead time correction is found to provide adequate dead time treatment for broad range of count rates available in practical applications.« less

  19. Thrombocytopenia in Small for Gestational Age Infants

    PubMed Central

    Christensen, Robert D.; Baer, Vickie L.; Henry, Erick; Snow, Gregory L.; Butler, Allison; Sola-Visner, Martha C.

    2016-01-01

    BACKGROUND Thrombocytopenia is common among small for gestational age neonates (SGA; birth weight <10th % reference range) but several aspects of this thrombocytopenia are unclear, including the incidence, typical nadir, duration, association with preeclampsia, mechanism, and risk of death. METHODS Using nine years of multihospital records we studied SGA neonates with ≥2 platelet counts <150,000/μL in their first week. RESULTS We found first-week thrombocytopenia in 31% (905 of 2891) of SGA neonates vs. 10% of non-SGA matched-controls (p<0.0001). One hundred-two of the 905 had a recognized cause of thrombocytopenia (DIC, early-onset sepsis, ECMO). This group had a 65% mortality rate. The remaining 803 did not have an obvious cause for their thrombocytopenia. We termed these the “thrombocytopenia of SGA”. They had a mortality rate of 2% (p<0.0001) and a mean nadir count on day 4 of 93,000/μL (standard deviation, 51,580/μL, 10th % 50,000/μL, 90th % 175,000/μL). By day 14, platelet counts were ≥150,000/μL in >half of the patients. Severely SGA neonates (<1st %) had lower counts and longer thrombocytopenia duration (p<0.001). High nucleated red cell counts at birth correlated with low platelets (p<0.0001). Platelet transfusions were given to 23% and counts typically >tripled. Thrombocytopenia was associated with SGA status more so than with the diagnosis of maternal preeclampsia. CONCLUSIONS SGA neonates with clearly recognized varieties of thrombocytopenia have a high mortality rate. In contrast the “thrombocytopenia of SGA” is a hyporegenerative condition of moderate severity and two weeks duration, associated with evidence of intrauterine hypoxia, and associated with a low mortality rate. PMID:26216323

  20. Use of Surveillance Data on HIV Diagnoses with HIV-Related Symptoms to Estimate the Number of People Living with Undiagnosed HIV in Need of Antiretroviral Therapy

    PubMed Central

    van Sighem, Ard; Sabin, Caroline A.; Phillips, Andrew N.

    2015-01-01

    Background It is important to have methods available to estimate the number of people who have undiagnosed HIV and are in need of antiretroviral therapy (ART). Methods The method uses the concept that a predictable level of occurrence of AIDS or other HIV-related clinical symptoms which lead to presentation for care, and hence diagnosis of HIV, arises in undiagnosed people with a given CD4 count. The method requires surveillance data on numbers of new HIV diagnoses with HIV-related symptoms, and the CD4 count at diagnosis. The CD4 count-specific rate at which HIV-related symptoms develop are estimated from cohort data. 95% confidence intervals can be constructed using a simple simulation method. Results For example, if there were 13 HIV diagnoses with HIV-related symptoms made in one year with CD4 count at diagnosis between 150–199 cells/mm3, then since the CD4 count-specific rate of HIV-related symptoms is estimated as 0.216 per person-year, the estimated number of person years lived in people with undiagnosed HIV with CD4 count 150–199 cells/mm3 is 13/0.216 = 60 (95% confidence interval: 29–100), which is considered an estimate of the number of people living with undiagnosed HIV in this CD4 count stratum. Conclusions The method is straightforward to implement within a short period once a surveillance system of all new HIV diagnoses, collecting data on HIV-related symptoms at diagnosis, is in place and is most suitable for estimating the number of undiagnosed people with CD4 count <200 cells/mm3 due to the low rate of developing HIV-related symptoms at higher CD4 counts. A potential source of bias is under-diagnosis and under-reporting of diagnoses with HIV-related symptoms. Although this method has limitations as with all approaches, it is important for prompting increased efforts to identify undiagnosed people, particularly those with low CD4 count, and for informing levels of unmet need for ART. PMID:25768925

  1. Use of surveillance data on HIV diagnoses with HIV-related symptoms to estimate the number of people living with undiagnosed HIV in need of antiretroviral therapy.

    PubMed

    Lodwick, Rebecca K; Nakagawa, Fumiyo; van Sighem, Ard; Sabin, Caroline A; Phillips, Andrew N

    2015-01-01

    It is important to have methods available to estimate the number of people who have undiagnosed HIV and are in need of antiretroviral therapy (ART). The method uses the concept that a predictable level of occurrence of AIDS or other HIV-related clinical symptoms which lead to presentation for care, and hence diagnosis of HIV, arises in undiagnosed people with a given CD4 count. The method requires surveillance data on numbers of new HIV diagnoses with HIV-related symptoms, and the CD4 count at diagnosis. The CD4 count-specific rate at which HIV-related symptoms develop are estimated from cohort data. 95% confidence intervals can be constructed using a simple simulation method. For example, if there were 13 HIV diagnoses with HIV-related symptoms made in one year with CD4 count at diagnosis between 150-199 cells/mm3, then since the CD4 count-specific rate of HIV-related symptoms is estimated as 0.216 per person-year, the estimated number of person years lived in people with undiagnosed HIV with CD4 count 150-199 cells/mm3 is 13/0.216 = 60 (95% confidence interval: 29-100), which is considered an estimate of the number of people living with undiagnosed HIV in this CD4 count stratum. The method is straightforward to implement within a short period once a surveillance system of all new HIV diagnoses, collecting data on HIV-related symptoms at diagnosis, is in place and is most suitable for estimating the number of undiagnosed people with CD4 count <200 cells/mm3 due to the low rate of developing HIV-related symptoms at higher CD4 counts. A potential source of bias is under-diagnosis and under-reporting of diagnoses with HIV-related symptoms. Although this method has limitations as with all approaches, it is important for prompting increased efforts to identify undiagnosed people, particularly those with low CD4 count, and for informing levels of unmet need for ART.

  2. A hierarchical spatial model of avian abundance with application to Cerulean Warblers

    USGS Publications Warehouse

    Thogmartin, Wayne E.; Sauer, John R.; Knutson, Melinda G.

    2004-01-01

    Surveys collecting count data are the primary means by which abundance is indexed for birds. These counts are confounded, however, by nuisance effects including observer effects and spatial correlation between counts. Current methods poorly accommodate both observer and spatial effects because modeling these spatially autocorrelated counts within a hierarchical framework is not practical using standard statistical approaches. We propose a Bayesian approach to this problem and provide as an example of its implementation a spatial model of predicted abundance for the Cerulean Warbler (Dendroica cerulea) in the Prairie-Hardwood Transition of the upper midwestern United States. We used an overdispersed Poisson regression with fixed and random effects, fitted by Markov chain Monte Carlo methods. We used 21 years of North American Breeding Bird Survey counts as the response in a loglinear function of explanatory variables describing habitat, spatial relatedness, year effects, and observer effects. The model included a conditional autoregressive term representing potential correlation between adjacent route counts. Categories of explanatory habitat variables in the model included land cover composition and configuration, climate, terrain heterogeneity, and human influence. The inherent hierarchy in the model was from counts occurring, in part, as a function of observers within survey routes within years. We found that the percentage of forested wetlands, an index of wetness potential, and an interaction between mean annual precipitation and deciduous forest patch size best described Cerulean Warbler abundance. Based on a map of relative abundance derived from the posterior parameter estimates, we estimated that only 15% of the species' population occurred on federal land, necessitating active engagement of public landowners and state agencies in the conservation of the breeding habitat for this species. Models of this type can be applied to any data in which the response is counts, such as animal counts, activity (e.g.,nest) counts, or species richness. The most noteworthy practical application of this spatial modeling approach is the ability to map relative species abundance. The functional relationships that we elucidated for the Cerulean Warbler provide a basis for the development of management programs and may serve to focus management and monitoring on areas and habitat variables important to Cerulean Warblers.

  3. Detection ratios on winter surveys of Rocky Mountain Trumpeter Swans Cygnus buccinator

    USGS Publications Warehouse

    Bart, J.; Mitchell, C.D.; Fisher, M.N.; Dubovsky, J.A.

    2007-01-01

    We estimated the detection ratio for Rocky Mountain Trumpeter Swans Cygnus buccinator that were counted during aerial surveys made in winter. The standard survey involved counting white or grey birds on snow and ice and thus might be expected to have had low detection ratios. On the other hand, observers were permitted to circle areas where the birds were concentrated multiple times to obtain accurate counts. Actual numbers present were estimated by conducting additional intensive aerial counts either immediately before or immediately after the standard count. Surveyors continued the intensive surveys at each area until consecutive counts were identical. The surveys were made at 10 locations in 2006 and at 19 locations in 2007. A total of 2,452 swans were counted on the intensive surveys. Detection ratios did not vary detectably with year, observer, which survey was conducted first, age of the swans, or the number of swans present. The overall detection ratio was 0.93 (90% confidence interval 0.82-1.04), indicating that the counts were quite accurate. Results are used to depict changes in population size for Rocky Mountain Trumpeter Swans from 1974-2007. ?? Wildfowl & Wetlands Trust.

  4. Prognostic implication of simultaneous anemia and lymphopenia during concurrent chemoradiotherapy in cervical squamous cell carcinoma.

    PubMed

    Cho, Oyeon; Chun, Mison; Oh, Young-Taek; Noh, O Kyu; Chang, Suk-Joon; Ryu, Hee-Sug; Lee, Eun Ju

    2017-10-01

    Radioresistance often leads to poor survival in concurrent chemoradiotherapy-treated cervical squamous cell carcinoma, and reliable biomarkers can improve prognosis. We compared the prognostic potential of hemoglobin, absolute neutrophil count, and absolute lymphocyte count with that of squamous cell carcinoma antigen in concurrent chemoradiotherapy-treated squamous cell carcinoma. We analyzed 152 patients with concurrent chemoradiotherapy and high-dose-rate intracavitary brachytherapy-treated cervical squamous cell carcinoma. Hemoglobin, absolute neutrophil count, absolute lymphocyte count, and squamous cell carcinoma antigen were quantitated and correlated with survival, using Cox regression, receiver operating characteristic curve analysis, and Kaplan-Meier plots. Both hemoglobin and absolute lymphocyte count in the second week of concurrent chemoradiotherapy (Hb2 and ALC2) and squamous cell carcinoma antigen in the third week of concurrent chemoradiotherapy (mid-squamous cell carcinoma antigen) correlated significantly with disease-specific survival and progression-free survival. The ratio of high-dose-rate intracavitary brachytherapy dose to total dose (high-dose-rate intracavitary brachytherapy ratio) correlated significantly with progression-free survival. Patients with both low Hb2 (≤11 g/dL) and ALC2 (≤639 cells/µL) showed a lower 5-year disease-specific survival rate than those with high Hb2 and/or ALC2, regardless of mid-squamous cell carcinoma antigen (mid-squamous cell carcinoma antigen: ≤4.7 ng/mL; 5-year disease-specific survival rate: 85.5% vs 94.6%, p = 0.0096, and mid-squamous cell carcinoma antigen: >4.7 ng/mL; 5-year disease-specific survival rate: 43.8% vs 66.7%, p = 0.192). When both Hb2 and ALC2 were low, the low high-dose-rate intracavitary brachytherapy ratio (≤0.43) subgroup displayed significantly lower 5-year disease-specific survival rate compared to the subgroup high high-dose-rate intracavitary brachytherapy ratio (>0.43) (62.5% vs 88.2%, p = 0.0067). Patients with both anemia and lymphopenia during concurrent chemoradiotherapy showed poor survival, independent of mid-squamous cell carcinoma antigen, and escalating high-dose-rate intracavitary brachytherapy ratio might improve survival.

  5. Ultra-fast photon counting with a passive quenching silicon photomultiplier in the charge integration regime

    NASA Astrophysics Data System (ADS)

    Zhang, Guoqing; Lina, Liu

    2018-02-01

    An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reach ~THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection.

  6. Multiplicity counting from fission detector signals with time delay effects

    NASA Astrophysics Data System (ADS)

    Nagy, L.; Pázsit, I.; Pál, L.

    2018-03-01

    In recent work, we have developed the theory of using the first three auto- and joint central moments of the currents of up to three fission chambers to extract the singles, doubles and triples count rates of traditional multiplicity counting (Pázsit and Pál, 2016; Pázsit et al., 2016). The objective is to elaborate a method for determining the fissile mass, neutron multiplication, and (α, n) neutron emission rate of an unknown assembly of fissile material from the statistics of the fission chamber signals, analogous to the traditional multiplicity counting methods with detectors in the pulse mode. Such a method would be an alternative to He-3 detector systems, which would be free from the dead time problems that would be encountered in high counting rate applications, for example the assay of spent nuclear fuel. A significant restriction of our previous work was that all neutrons born in a source event (spontaneous fission) were assumed to be detected simultaneously, which is not fulfilled in reality. In the present work, this restriction is eliminated, by assuming an independent, identically distributed random time delay for all neutrons arising from one source event. Expressions are derived for the same auto- and joint central moments of the detector current(s) as in the previous case, expressed with the singles, doubles, and triples (S, D and T) count rates. It is shown that if the time-dispersion of neutron detections is of the same order of magnitude as the detector pulse width, as they typically are in measurements of fast neutrons, the multiplicity rates can still be extracted from the moments of the detector current, although with more involved calibration factors. The presented formulae, and hence also the performance of the proposed method, are tested by both analytical models of the time delay as well as with numerical simulations. Methods are suggested also for the modification of the method for large time delay effects (for thermalised neutrons).

  7. On-Orbit Sky Background Measurements with the FOS

    NASA Technical Reports Server (NTRS)

    Lyons, R. W.; Baity, W. A.; Beaver, E. A.; Cohen, R. D.; Junkkarinen, V. T.; Linsky, J. B.; Bohlin, R. C.

    1993-01-01

    Observations of the sky background obtained with the Faint Object Spectrograph during 1991-1992 are discussed. Sky light can be an important contributor to the observed count rate in several of the instrument configurations especially when large apertures are used. In general, the sky background is consistent with the pre-launch expectations and showed the expected effects of zodiacal light and diffuse galactic light. In addition to these sources, there is, particularly during the daytime, a highly variable airglow component which includes a number of emission lines. The sky background will have an impact on the reduction and possibly the interpretation of some spectra.

  8. Early and sustained efficacy with apremilast monotherapy in biological-naïve patients with psoriatic arthritis: a phase IIIB, randomised controlled trial (ACTIVE).

    PubMed

    Nash, Peter; Ohson, Kamal; Walsh, Jessica; Delev, Nikolay; Nguyen, Dianne; Teng, Lichen; Gómez-Reino, Juan J; Aelion, Jacob A

    2018-05-01

    Evaluate apremilast efficacy across various psoriatic arthritis (PsA) manifestations beginning at week 2 in biological-naïve patients with PsA. Patients were randomised (1:1) to apremilast 30 mg twice daily or placebo. At week 16, patients whose swollen and tender joint counts had not improved by ≥10% were eligible for early escape. At week 24, all patients received apremilast through week 52. Among 219 randomised patients (apremilast: n=110; placebo: n=109), a significantly greater American College of Rheumatology 20 response at week 16 (primary outcome) was observed with apremilast versus placebo (38.2% (42/110) vs 20.2% (22/109); P=0.004); response rates at week 2 (first assessment) were 16.4% (18/110) versus 6.4% (7/109) (P=0.025). Improvements in other efficacy outcomes, including 28-joint count Disease Activity Score (DAS-28) using C reactive protein (CRP), swollen joint count, Health Assessment Questionnaire-Disability Index (HAQ-DI), enthesitis and morning stiffness severity, were observed with apremilast at week 2. At week 16, apremilast significantly reduced PsA disease activity versus placebo, with changes in DAS-28 (CRP) (P<0.0001), HAQ-DI (P=0.023) and Gladman Enthesitis Index (P=0.001). Improvements were maintained with continued treatment through week 52. Over 52 weeks, apremilast's safety profile was consistent with prior phase 3 studies in psoriasis and PsA. During weeks 0-24, the incidence of protocol-defined diarrhoea was 11.0% (apremilast) and 8.3% (placebo); serious adverse event rates were 2.8% (apremilast) and 4.6% (placebo). In biological-naïve patients with PsA, onset of effect with apremilast was observed at week 2 and continued through week 52. The safety profile was consistent with previous reports. NCT01925768; Results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Count distribution for mixture of two exponentials as renewal process duration with applications

    NASA Astrophysics Data System (ADS)

    Low, Yeh Ching; Ong, Seng Huat

    2016-06-01

    A count distribution is presented by considering a renewal process where the distribution of the duration is a finite mixture of exponential distributions. This distribution is able to model over dispersion, a feature often found in observed count data. The computation of the probabilities and renewal function (expected number of renewals) are examined. Parameter estimation by the method of maximum likelihood is considered with applications of the count distribution to real frequency count data exhibiting over dispersion. It is shown that the mixture of exponentials count distribution fits over dispersed data better than the Poisson process and serves as an alternative to the gamma count distribution.

  10. Cryptosporidium and other intestinal parasitic infections among HIV patients in southern Ethiopia: significance of improved HIV-related care.

    PubMed

    Shimelis, Techalew; Tassachew, Yayehyirad; Lambiyo, Tariku

    2016-05-10

    Intestinal parasitic infections are known to cause gastroenteritis, leading to higher morbidity and mortality, particularly in people living with HIV/AIDS. This study aimed to determine the prevalence of Cryptosporidium and other intestinal parasitic infections among HIV patients receiving care at a hospital in Ethiopia where previous available baseline data helps assess if improved HIV-related care has reduced infection rates. A cross-sectional study was conducted at Hawassa University Hospital in southern Ethiopia from May, 2013 to March, 2014. A consecutive sample of 491 HIV- infected patients with diarrhea or a CD4 T cell count < 200 cells/μl were prospectively studied. A single stool sample was collected from each study participant and processed using direct, formol-ether concentration, and modified Ziehl-Neelsen techniques for the diagnosis of Cryptosporidium and other intestinal parasites. The study was approved by the Institutional Review Board of the College of Medicine and Health Sciences, Hawassa University. Physicians managed participants found to be infected with any pathogenic intestinal parasite. The overall prevalence of intestinal parasitic infections among the study population was 35.8 %. The most prevalent parasites were Cryptosporidium (13.2 %), followed by Entamoeba histolytica/dispar (10.2 %), and Giardia lamblia (7.9 %). The rate of single and multiple infections were 25.5 and 10.3 %, respectively. Patients with a CD4 T cell count < 200 cells/μl had a similar rate of any intestinal parasitic infection or cryptosporidiosis compared to those with counts ≥ 200 cells/μl, but with some type of diarrhea. The study shows high prevalence of intestinal parasitic infections in the study population. However, the results in the current report are significantly lower compared to previous findings in the same hospital. The observed lower infection rate is encouraging and supports the need to strengthen and sustain the existing intervention measures in order to further reduce intestinal parasitic infections in people living with HIV/AIDS.

  11. The effect of calabash chalk on some hematological parameters in female adult Wistar rats.

    PubMed

    Akpantah, Amabe Otoabasi; Ibok, Ofon Samuel; Ekong, Moses Bassey; Eluwa, Mokutima Amarachi; Ekanem, Theresa Bassey

    2010-09-05

    Calabash chalk is a naturally occurring mineral consumed among the Nigerian community for pleasure and commonly by pregnant women as a remedy for morning sickness. Reports have shown that it contains different toxic substances, with lead being the most abundant. This study was therefore undertaken to ascertain the effect of two commonly available preparations of this chalk on some hematological parameters. Twenty-four adult female Wistar rats with average weight of 100 g were assigned into three groups (1, 2, 3). Group 1 served as the control and the animals received distilled water, while Groups 2 and 3 were treated by oral gavage with 40 mg/kg of non-salted (NSCC) and salted calabash chalk (SCC), respectively, for 14 days. The hemoglobin (Hb) concentration and red blood cell (RBC) count were significantly (p<0.05, 0.001 respectively) lower in the NSCC group, while erythrocyte sedimentation rate (ESR) was significantly (p<0.05) higher in the NSCC group compared to the control. There were no significant differences in packed cell volume (PCV), white blood cell (WBC) and platelet (Pl) counts compared to the control. The SCC group presented no significant difference in all blood count parameters compared to the control. This infers that calabash chalk, particularly the non-salted form, alters the normal concentration of Hb, RBC and Pl counts, and ESR, as observed in the female Wistar rats studied.

  12. Silicon Quantum Dots with Counted Antimony Donor Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, Meenakshi; Pacheco, Jose L.; Perry, Daniel Lee

    2015-10-01

    Deterministic control over the location and number of donors is crucial to donor spin quantum bits (qubits) in semiconductor based quantum computing. A focused ion beam is used to implant close to quantum dots. Ion detectors are integrated next to the quantum dots to sense the implants. The numbers of ions implanted can be counted to a precision of a single ion. Regular coulomb blockade is observed from the quantum dots. Charge offsets indicative of donor ionization, are observed in devices with counted implants.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erchinger, J. L.; Orrell, John L.; Aalseth, C. E.

    The Ultra-Low Background Liquid Scintillation Counter developed by Pacific Northwest National Laboratory will expand the application of liquid scintillation counting by enabling lower detection limits and smaller sample volumes. By reducing the overall count rate of the background environment approximately 2 orders of magnitude below that of commercially available systems, backgrounds on the order of tens of counts per day over an energy range of ~3–3600 keV can be realized. Finally, initial test results of the ULB LSC show promising results for ultra-low background detection with liquid scintillation counting.

  14. High-fidelity frequency down-conversion of visible entangled photon pairs with superconducting single-photon detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ikuta, Rikizo; Kato, Hiroshi; Kusaka, Yoshiaki

    We experimentally demonstrate a high-fidelity visible-to-telecommunicationwavelength conversion of a photon by using a solid-state-based difference frequency generation. In the experiment, one half of a pico-second visible entangled photon pair at 780 nm is converted to a 1522-nm photon. Using superconducting single-photon detectors with low dark count rates and small timing jitters, we observed a fidelity of 0.93±0.04 after the wavelength conversion.

  15. The particle background observed by the X-ray detectors onboard Copernicus

    NASA Technical Reports Server (NTRS)

    Davison, P. J. N.

    1974-01-01

    The design and characteristics of low energy detectors on the Copernicus satellite are described. The functions of the sensors in obtaining data on the particle background. The procedure for processing the data obtained by the satellite is examined. The most significant positive deviations are caused by known weak X-ray sources in the field of view. In addition to small systemic effects, occasional random effects where the count rate increases suddenly and decreases within a few frames are analyzed.

  16. COS/FUV Mapping of Stray PtNe Lamp Light Through FCA

    NASA Astrophysics Data System (ADS)

    Oliveira, Cristina

    2010-09-01

    This program determines which cross-dispersion locations lead to wavecal lamp {PtNe} light leaking through the flat-field calibration aperture {FCA}. This unexpected effect, observed initially in program 12096, led to a shut down of the COS/FUV detector due to a global count rate violation in Segment A of the G140L/1230 setting. Detector? threshold ?is ?600,000 ?FEC ?counts ?in? 10 seconds ?on each ?segment. ?If ?this ?level? is ?exceeded, ?the? detector? shuts ?down? the ?HV.In program 12096, for the G140L/1230 setting, at +6" from the nominal position in the cross-dispersion direction, 180,000 cts/sec were observed through the FCA in Segment A, and 49,000 cts/sec in Segment B {PtNe/FCA}. The corresponding wavecal count rate {PtNe/WCA} is 685 cts/sec in Segment A, implying that there is a scale factor of 263 between the FCA and WCA count rates. This scale factor could not be verified for Segment B, given that the PtNe lamp does not produce counts at the short wavelengths seen by G140L/1230/FUVB. However, this scaling factor is expected to be the same for both segments.The scaling factor derived from program 12096 is then used to predict the FCA count rates seen with all the gratings, in off-nominal positions where light might leak through the FCA in the current program.There is no light leak between the nominal position and positions up to and including +3" {at least not in Mar 2010 when program 12096 executed}, but somewhere above +3" and certainly at +6" the PtNe light starts leaking through the FCA.Light is not predicted to leak at negative POS-TARG positions from the nominal, and the purpose of this program is to verify that as well.Visits 1N to 6N take data at positions from +1.0" to +6.0", while visits 1S to 6S take data at positions from -1.0" to -6.0". Visits 10 through 13 take data at the nominal position, 0.0".At each position in the detector data is taken with the following settings:G130M/1055/1291/1327, G160M/1577/1623, and G140L/1280/1105, in this order.LAMP2 with CURRENT=LOW is used in all of these visits. In addition, at each position, one exposure with LAMP1 CURRENT=MED is also taken with the G130M/1055 setting, which leads to total counts in 10 sec more than a factor of 10 below the 600,000 limit. This exposure is used so that the ratio of LAMP1/MED to LAMP2/LOW can be calculated for the FCA at each position {in conjunction with the data obtained in visits 11, 12, and 13; see below}. In addition, the G130M/1055 exposures with LAMP1/MED and LAMP2/LOW will be used to determine if the lamp spot size is changing at each position.Depending on the total counts estimated for each setting, either a typical wave exposure is taken or special flash commands are used. Details are given in each visit.Exposures obtained with LAMP1/CURRENT=LOW are expected to have a 20% smaller count rate than exposures obtained with LAMP1/CURRENT=MED. Exposures obtained with LAMP2/CURRENT=MED are expected to have count rates similar to those obtained with LAMP1/CURRENT=MED, and exposures obtained with LAMP2/CURRENT=LOW are expected to have a count rate which is 1/7 of that obtainedwith LAMP2/CURRENT=MED.VISIT 10 OBTAINS LAMP1/CURRENT=MED+ LOW SPECTRA AT ALL THE M SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.VISIT 11 OBTAINS LAMP2/CURRENT=MED SPECTRA AT ALL THE M SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.VISIT 12 OBTAINS LAMP2/CURRENT=LOW SPECTRA AT ALL THE M SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.VISIT 13 OBTAINS LAMP1/CURRENT=MED, LOW AND LAMP2/CURRENT=MED, LOW SPECTRA AT ALL OF THE L SETTINGS USED IN THIS PROGRAM, AT THE NOMINAL POSITION {0.0"}.THE GOAL OF THESE VISITS IS TO DETERMINE THE RATIOS OF THE DIFFERENT LAMP SETTINGS AT DIFFERENT WAVELENGTHS, TO HELP IN ANALYZING THE DATA OBTAINED IN VISITS WHERE ONLY LAMP2/LOW IS USED.ALSO, THESE DATA WILL BE USED TO PREDICT WHAT THE COUNTS WOULD BE WITH G140L/1280/LAMP1/MED AT THE +6.0" POSITION {VIS6N, WHERE LAMP2/LOW IS USED}. THESE COUNTS WILL BE COMPARED WITH THE COUNTS OBTAINED IN PROGRAM 12096 WITH G140L/1230/LAMP1/MED, MORE THAN ONE YEAR AGO, TO LOOK FOR VARIABILITY, POSSIBLY INDICATING CHANGES TO THE LAMP SPOT SIZE.Visits 10 through 13, all executed at the nominal position, pose no safety concerns.CONSTRAINTS:- Visits 1N, 2N, 3N can be executed back to back as no light is expected to leak through the FCA. Visit 1N should execute before visit 2N, which should execute before visit 3N.- Visits 1S, 2S, and 3S can be executed back to back and do not have constraints relative to the other visits. Visit 1S should execute before visit 2S, which should execute before visit 3S- Visits 10, 11, 12, and 13 {data obtained at nominal position}, can also be executed back to back and have no constraints relative to other visits. However, these visits should be scheduled as soon as possible, because results of data anaysis will be used to inform execution of program 12678.- There should be an interval of at least two days between any of the visits mentioned above and the other visits in this program {4N, 5N, 6N, 4S, 5S, 6S} which could see light leaking through the FCA.- Visits 4S and 4N can be scheduled in the same week, but they don't need to be.- Visits 5S and 5N can be scheduled in the same week, but they don't need to be.- There should be an interval of at least 3 weeks between visit 4N and visit 5N.- Visits 6S and 6N can be scheduled in the same week, but they don't need to be.- There should be an interval of at least 3 weeks between visit 5N and visit 6N.- Visits 1S through 5S should be scheduled as soon as possible, the same is true for visits 1N to 4N.

  17. Comparative Effectiveness of Two Walking Interventions on Participation, Step Counts, and Health.

    PubMed

    Smith-McLallen, Aaron; Heller, Debbie; Vernisi, Kristin; Gulick, Diana; Cruz, Samantha; Snyder, Richard L

    2017-03-01

    To (1) compare the effects of two worksite-based walking interventions on employee participation rates; (2) compare average daily step counts between conditions, and; (3) examine the effects of increases in average daily step counts on biometric and psychologic outcomes. We conducted a cluster-randomized trial in which six employer groups were randomly selected and randomly assigned to condition. Four manufacturing worksites and two office-based worksite served as the setting. A total of 474 employees from six employer groups were included. A standard walking program was compared to an enhanced program that included incentives, feedback, competitive challenges, and monthly wellness workshops. Walking was measured by self-reported daily step counts. Survey measures and biometric screenings were administered at baseline and 3, 6, and 9 months after baseline. Analysis used linear mixed models with repeated measures. During 9 months, participants in the enhanced condition averaged 726 more steps per day compared with those in the standard condition (p < .001). A 1000-step increase in average daily steps was associated with significant weight loss for both men (-3.8 lbs.) and women (-2.1 lbs.), and reductions in body mass index (-0.41 men, -0.31 women). Higher step counts were also associated with improvements in mood, having more energy, and higher ratings of overall health. An enhanced walking program significantly increases participation rates and daily step counts, which were associated with weight loss and reductions in body mass index.

  18. A Neutron Burst Associated with an Extensive Air Shower?

    NASA Astrophysics Data System (ADS)

    Alves, Mauro; Martin, Inacio; Shkevov, Rumen; Gusev, Anatoly; De Abreu, Alessandro

    2016-07-01

    A portable and compact system based on a He-3 tube (LND, USA; model 25311) with an area of approximately 250 cm² and is used to record neutron count rates at ground level in the energy range of 0.025 eV to 10 MeV, in São José dos Campos, SP, Brazil (23° 12' 45" S, 45° 52' 00" W; altitude, 660m). The detector, power supply, digitizer and other hardware are housed in an air-conditioned room. The detector power supply and digitizer are not connected to the main electricity network; a high-capacity 12-V battery is used to power the detector and digitizer. Neutron counts are accumulated at 1-minute intervals continuously. The data are stored in a PC for further analysis. In February 8, 2015, at 12 h 22 min (local time) during a period of fair weather with minimal cloud cover (< 1 okta) the neutron detector recorded a sharp (count rate = 27 neutrons/min) and brief (< 1 min) increase in the count rate. In the days before and after this event, the neutron count rate has oscillated between 0 and 3 neutrons/min. Since the occurrence of this event is not related with spurious signals, malfunctioning equipment, oscillations in the mains voltage, etc. we are led to believe that the sharp increase was caused by a physical source such as a an extensive air shower that occurred over the detector.

  19. Performance assessment of self-interrogation neutron resonance densitometry for spent nuclear fuel assay

    NASA Astrophysics Data System (ADS)

    Hu, Jianwei; Tobin, Stephen J.; LaFleur, Adrienne M.; Menlove, Howard O.; Swinhoe, Martyn T.

    2013-11-01

    Self-Interrogation Neutron Resonance Densitometry (SINRD) is one of several nondestructive assay (NDA) techniques being integrated into systems to measure spent fuel as part of the Next Generation Safeguards Initiative (NGSI) Spent Fuel Project. The NGSI Spent Fuel Project is sponsored by the US Department of Energy's National Nuclear Security Administration to measure plutonium in, and detect diversion of fuel pins from, spent nuclear fuel assemblies. SINRD shows promising capability in determining the 239Pu and 235U content in spent fuel. SINRD is a relatively low-cost and lightweight instrument, and it is easy to implement in the field. The technique makes use of the passive neutron source existing in a spent fuel assembly, and it uses ratios between the count rates collected in fission chambers that are covered with different absorbing materials. These ratios are correlated to key attributes of the spent fuel assembly, such as the total mass of 239Pu and 235U. Using count rate ratios instead of absolute count rates makes SINRD less vulnerable to systematic uncertainties. Building upon the previous research, this work focuses on the underlying physics of the SINRD technique: quantifying the individual impacts on the count rate ratios of a few important nuclides using the perturbation method; examining new correlations between count rate ratio and mass quantities based on the results of the perturbation study; quantifying the impacts on the energy windows of the filtering materials that cover the fission chambers by tallying the neutron spectra before and after the neutrons go through the filters; and identifying the most important nuclides that cause cooling-time variations in the count rate ratios. The results of these studies show that 235U content has a major impact on the SINRD signal in addition to the 239Pu content. Plutonium-241 and 241Am are the two main nuclides responsible for the variation in the count rate ratio with cooling time. In short, this work provides insights into some of the main factors that affect the performance of SINRD, and it should help improve the hardware design and the algorithm used to interpret the signal for the SINRD technique. In addition, the modeling and simulation techniques used in this work can be easily adopted for analysis of other NDA systems, especially when complex systems like spent nuclear fuel are involved. These studies were conducted at Los Alamos National Laboratory.

  20. Variability of Seasonal CO2 Ice Caps on Mars for Mars Years 26 through 29

    NASA Astrophysics Data System (ADS)

    Feldman, W. C.; Maurice, S.; Prettyman, T. H.

    2011-12-01

    We have developed an improved thermal, epithermal, and fast neutron counting-rate time series data of the Mars Odyssey Neutron Spectrometer (MONS), optimized to greatly reduce both statistical and systematic uncertainties. This new data set was applied to study temporal and spatial distributions of the growth, decay, and maximum amount of precipitated CO2 ice during Martian years (MY) 26, 27, 28, and 29. For this study, we concentrate on the epithermal counting rate detected using the down-looking prism (P1) of MONS, and a combination of the epithermal and thermal counting rate detected by the forward-looking sensor (P2) of MONS. Although the energy range of neutrons detected by P2 covers both the thermal and epithermal range, it is heavily weighted to the thermal range. We find that the variance of the maximum epithermal counting rate is remarkably small over both north and south seasonal caps, varying by less than 3% over the four-year period. In contrast, although the maximum P2 counting rate over both poles is sensibly the same within error bars (about 2%) during the first three years, it drops by 18% over the north pole and 8% over the south pole during MY 29. The most-likely explanation of this drop is that abundances of the non-condensable gases N2 and Ar, are unusually enhanced during MY 29. Movies were also made of maps of the growth and decay of P2 counting rates summed over the first three years of these data. Careful inspection shows that both the growth and decay in the north were cylindrically symmetric, centered near the geographic north pole. In contrast, both the growth and decay of CO2 buildup in the south were skewed off the geographic pole to the center of the CO2 residual cap, and contained a small, but definitely distinct ring-like annular enhancement centered at a latitude of about 83.5° S spread over a longitude range that extends between about -35° and +35° E. This arc runs parallel to, and overlays, the very steep drop in altitude from the top of the south-polar CO2/water-ice residual cap at about +4.2 km to the surrounding plains at about +2.5 km. Algorithms developed previously to convert counting rates to CO2 and noncondensable gas column abundance will be applied to interpret the data.

Top