Sample records for counters radiation

  1. GAMMA PROPORTIONAL COUNTER CONTAINING HIGH Z GAS AND LOW Z MODERATOR

    DOEpatents

    Fox, R.

    1963-07-23

    A gamma radiation counter employing a gas proportional counter is described. The radiation counter comprises a cylindrical gas proportional counter which contains a high atomic number gas and is surrounded by a low atomic number gamma radiation moderator material. At least one slit is provided in the moderator to allow accident gamma radiation to enter the moderator in the most favorable manner for moderation, and also to allow low energy gamma radiation to enter the counter without the necessity of passing through the moderator. This radiation counter is capable of detecting and measuring gamma radiation in the energy range of 0.5-5 Mev. (AEC)

  2. Proportional counter radiation camera

    DOEpatents

    Borkowski, C.J.; Kopp, M.K.

    1974-01-15

    A gas-filled proportional counter camera that images photon emitting sources is described. A two-dimensional, positionsensitive proportional multiwire counter is provided as the detector. The counter consists of a high- voltage anode screen sandwiched between orthogonally disposed planar arrays of multiple parallel strung, resistively coupled cathode wires. Two terminals from each of the cathode arrays are connected to separate timing circuitry to obtain separate X and Y coordinate signal values from pulse shape measurements to define the position of an event within the counter arrays which may be recorded by various means for data display. The counter is further provided with a linear drift field which effectively enlarges the active gas volume of the counter and constrains the recoil electrons produced from ionizing radiation entering the counter to drift perpendicularly toward the planar detection arrays. A collimator is interposed between a subject to be imaged and the counter to transmit only the radiation from the subject which has a perpendicular trajectory with respect to the planar cathode arrays of the detector. (Official Gazette)

  3. Nuclear Forensics and Radiochemistry: Radiation Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rundberg, Robert S.

    Radiation detection is necessary for isotope identification and assay in nuclear forensic applications. The principles of operation of gas proportional counters, scintillation counters, germanium and silicon semiconductor counters will be presented. Methods for calibration and potential pitfalls in isotope quantification will be described.

  4. GASEOUS SCINTILLATION COUNTER

    DOEpatents

    Eggler, C.; Huddleston, C.M.

    1959-04-28

    A gaseous excitation counter for detecting the presence amd measuring the energy of subatomic particles and electromagnetic radiation is described. The counter includes a gas-tight chamber filled with an elemental gas capable of producing ultra-violet excitation quanta when irradiated with subatomic particles and electromagnetic radiation. The gas has less than one in a thousand parts ultra-violet absorbing contamination. When nuclear radiation ps present the ultra-violet light produced by the gas strikes a fluorescent material within the counter, responsive to produce visible excitation quanta, and photo-sensitive counting means detect the visible emission.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawano, T.; Tanaka, M.; Isozumi, S.

    Air exerts a negative effect on radiation detection using a gas counter because oxygen contained in air has a high electron attachment coefficient and can trap electrons from electron-ion pairs created by ionization from incident radiation in counting gas. This reduces radiation counts. The present study examined the influence of air on energy and rise-time spectra measurements using a proportional gas counter. In addition, a decompression procedure method was proposed to reduce the influence of air and its effectiveness was investigated. For the decompression procedure, the counting gas inside the gas counter was decompressed below atmospheric pressure before radiation detection.more » For the spectrum measurement, methane as well as various methane and air mixtures were used as the counting gas to determine the effect of air on energy and rise-time spectra. Results showed that the decompression procedure was effective for reducing or eliminating the influence of air on spectra measurement using a proportional gas counter. (authors)« less

  6. A history of radiation detection instrumentation.

    PubMed

    Frame, Paul W

    2004-08-01

    A review is presented of the history of radiation detection instrumentation. Specific radiation detection systems that are discussed include the human senses, photography, calorimetry, color dosimetry, ion chambers, electrometers, electroscopes, proportional counters, Geiger Mueller counters, scalers and rate meters, barium platinocyanide, scintillation counters, semiconductor detectors, radiophotoluminescent dosimeters, thermoluminescent dosimeters, optically stimulated luminescent dosimeters, direct ion storage, electrets, cloud chambers, bubble chambers, and bubble dosimeters. Given the broad scope of this review, the coverage is limited to a few key events in the development of a given detection system and some relevant operating principles. The occasional anecdote is included for interest.

  7. A history of radiation detection instrumentation.

    PubMed

    Frame, Paul W

    2005-06-01

    A review is presented of the history of radiation detection instrumentation. Specific radiation detection systems that are discussed include the human senses, photography, calorimetry, color dosimetry, ion chambers, electrometers, electroscopes, proportional counters, Geiger Mueller counters, scalers and rate meters, barium platinocyanide, scintillation counters, semiconductor detectors, radiophotoluminescent dosimeters, thermoluminescent dosimeters, optically stimulated luminescent dosimeters, direct ion storage, electrets, cloud chambers, bubble chambers, and bubble dosimeters. Given the broad scope of this review, the coverage is limited to a few key events in the development of a given detection system and some relevant operating principles. The occasional anecdote is included for interest.

  8. Calibration of the active radiation detector for Spacelab-One

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The flight models of the active radiation detector (ARD) for the ENV-01 environmental monitor were calibrated using gamma radiation. Measured sensitivities of the ion chambers were 6.1 + or - 0.3 micron rad per count for ARD S/N1, and 10.4 + or - 0.5 micron rad per count for ARD S/N2. Both were linear over the measured range 0.10 to 500 m/rad hour. The particle counters (proportional counters) were set to respond to approximately 85% of minimum ionizing particles of unit charge passing through them. These counters were also calibrated in the gamma field.

  9. Construction of silica aerogel radiator system for Belle II RICH Counter

    NASA Astrophysics Data System (ADS)

    Adachi, I.; Dolenec, R.; Hataya, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Križan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Ogawa, S.; Pestotnik, R.; Šantelj, L.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.; Yusa, Y.

    2017-12-01

    We have developed a RICH counter as a new forward particle identification device for the Belle II experiment. As a Cherenkov radiator in this counter, a dual aerogel layer combination consisting of two refractive indicies, n=1.045 and 1.055, is employed. Mass production of these aerogel tiles has been done during 2013-2014 with new method improved by Chiba group. Optical qualities for them have been examined. The refractive indices of the obtained tiles were found to be in good agreement with our expectations, and the transparencies were high enough to be used for the RICH radiator.

  10. GEIGER-MULLER TYPE COUNTER TUBE

    DOEpatents

    Fowler, I.L.; Watt, L.A.K.

    1959-12-15

    A single counter tube capable of responding to a wide range of intensities is described. The counter tube comprises a tubular cathode and an anode extending centrally of the cathode. The spacing between the outer surface of the anode and the inner surface of the cathode is varied along the length of the tube to provide different counting volumes in adjacent portions of the tube. A large counting volume in one portion adjacent to a low-energy absorption window gives adequate sensitivity for measuring lowintensity radiation, while a smaller volume with close electrode spacing is provided in the counter to make possible measurement of intense garnma radiation fields.

  11. Radiation detectors and sources enhanced with micro/nanotechnology

    NASA Astrophysics Data System (ADS)

    Whitney, Chad Michael

    The ongoing threat of nuclear terrorism presents major challenges to maintaining national security. Currently, only a small percentage of the cargo containers that enter America are searched for fissionable bomb making materials. This work reports on a multi-channel radiation detection platform enabled with nanoparticles that is capable of detecting and discriminating all types of radiation emitted from fissionable bomb making materials. Typical Geiger counters are limited to detecting only beta and gamma radiation. The micro-Geiger counter reported here detects all species of radiation including beta particles, gamma/X-rays, alpha particles, and neutrons. The multi-species detecting micro-Geiger counter contains a hermetically sealed and electrically biased fill gas. Impinging radiation interacts with tailored nanoparticles to release secondary charged particles that ionize the fill gas. The ionized particles collect on respectively biased electrodes resulting in a characteristic electrical pulse. Pulse height spectroscopy and radiation energy binning techniques can then be used to analyze the pulses to determine the specific radiation isotope. The ideal voltage range of operation for energy discrimination was found to be in the proportional region at 1000VDC. In this region, specific pulse heights for different radiation species resulted. The amplification region strength which determines the device sensitivity to radiation energy can be tuned with the electrode separation distance. Considerable improvements in count rates were achieved by using the charge conversion nanoparticles with the highest cross sections for particular radiation species. The addition of tungsten nanoparticles to the microGeiger counter enabled the device to be four times more efficient at detecting low level beta particles with a dose rate of 3.2uR/hr (micro-Roentgen per hour) and just under three times more efficient than an off the shelf Geiger counter. The addition of lead nanoparticles enabled the gamma/X-ray microGeiger counter channel to be 28 times more efficient at detecting low level gamma rays with a dose rate of 10uR/hr when compared to a device without nanoparticles. The addition of 10B nanoparticles enabled the neutron microGeiger counter channel to be 17 times more efficient at detecting neutrons. The device achieved a neutron count rate of 9,866 counts per minute when compared to a BF3 tube which resulted in a count rate of 9,000 counts per minute. By using a novel micro-injection ceramic molding and low temperature (950°C) silver paste metallizing process, the batch fabrication of essentially disposable micro-devices can be achieved. This novel fabrication technique was then applied to a MEMS neutron gun and water spectroscopy device that also utilizes the high voltage/temperature insulating packaging.

  12. Shielding concepts for low-background proportional counter arrays in surface laboratories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Humble, Paul H.; Mace, Emily K.

    2016-02-01

    Development of ultra low background gas proportional counters has made the contribution from naturally occurring radioactive isotopes – primarily and activity in the uranium and thorium decay chains – inconsequential to instrumental sensitivity levels when measurements are performed in above ground surface laboratories. Simple lead shielding is enough to mitigate against gamma rays as gas proportional counters are already relatively insensitive to naturally occurring gamma radiation. The dominant background in these surface laboratory measurements using ultra low background gas proportional counters is due to cosmic ray generated muons, neutrons, and protons. Studies of measurements with ultra low background gas proportionalmore » counters in surface and underground laboratories as well as radiation transport Monte Carlo simulations suggest a preferred conceptual design to achieve the highest possible sensitivity from an array of low background gas proportional counters when operated in a surface laboratory. The basis for a low background gas proportional counter array and the preferred shielding configuration is reported, especially in relation to measurements of radioactive gases having low energy decays such as 37Ar.« less

  13. Sea Buckthorn Leaf Extract Protects Jejunum and Bone Marrow of (60)Cobalt-Gamma-Irradiated Mice by Regulating Apoptosis and Tissue Regeneration.

    PubMed

    Bala, Madhu; Gupta, Manish; Saini, Manu; Abdin, M Z; Prasad, Jagdish

    2015-01-01

    A single dose (30 mg/kg body weight) of standardized sea buckthorn leaf extract (SBL-1), administered 30 min before whole body (60)Co-gamma-irradiation (lethal dose, 10 Gy), protected >90% of mice population. The purpose of this study was to investigate the mechanism of action of SBL-1 on jejunum and bone marrow, quantify key bioactive compounds, and analyze chemical composition of SBL-1. Study with 9-week-old inbred male Swiss albino Strain 'A' mice demonstrated that SBL-1 treatment before (60)Co-gamma-irradiation (10 Gy) significantly (p < 0.05) countered radiation induced decreases in jejunum crypts (1.27-fold), villi number (1.41-fold), villus height (1.25-fold), villus cellularity (2.27-fold), cryptal Paneth cells (1.89-fold), and Bcl2 level (1.54-fold). It countered radiation induced increases in cryptal apoptotic cells (1.64-fold) and Bax levels (1.88-fold). It also countered radiation (2 Gy and 3 Gy) induced bone marrow apoptosis (1.59-fold and 1.85-fold) and micronuclei frequency (1.72-fold and 2.6-fold). SBL-1 rendered radiation protection by promoting cryptal stem cells proliferation, by regulating apoptosis, and by countering radiation induced chromosomal damage. Quercetin, Ellagic acid, Gallic acid, high contents polyphenols, tannins, and thiols detected in SBL-1 may have contributed to radiation protection by neutralization of radiation induced oxidative species, supporting stem cell proliferation and tissue regeneration.

  14. Air Proportional Counter

    DOEpatents

    Simpson, Jr, J A

    1950-12-05

    A multiple wire counter utilizing air at atmospheric pressure as the ionizing medium and having a window of a nylon sheet of less than 0.5 mil thickness coated with graphite. The window is permeable to alpha particles so that the counter is well adapted to surveying sources of alpha radiation.

  15. THE OUTER RADIATION BELT OF THE EARTH AT THE ALTITUDE OF 320 KM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vernov, S.N.; Savenko, I.A.; Shavrin, P.I.

    1962-11-01

    Scintillation and gas-discharge counters on the second Soviet spaceship allowed a detailed investigation of the outer radiation belt near the earth and established its boundaries in relation to longitude. The spaceship orbit was almost circular at an altitude of 306 to 339 km. The energy threshold of the counter channel was 25 kev. (W,D.M.)

  16. Sea Buckthorn Leaf Extract Protects Jejunum and Bone Marrow of 60Cobalt-Gamma-Irradiated Mice by Regulating Apoptosis and Tissue Regeneration

    PubMed Central

    Gupta, Manish; Saini, Manu; Abdin, M. Z.; Prasad, Jagdish

    2015-01-01

    A single dose (30 mg/kg body weight) of standardized sea buckthorn leaf extract (SBL-1), administered 30 min before whole body 60Co-gamma-irradiation (lethal dose, 10 Gy), protected >90% of mice population. The purpose of this study was to investigate the mechanism of action of SBL-1 on jejunum and bone marrow, quantify key bioactive compounds, and analyze chemical composition of SBL-1. Study with 9-week-old inbred male Swiss albino Strain ‘A' mice demonstrated that SBL-1 treatment before 60Co-gamma-irradiation (10 Gy) significantly (p < 0.05) countered radiation induced decreases in jejunum crypts (1.27-fold), villi number (1.41-fold), villus height (1.25-fold), villus cellularity (2.27-fold), cryptal Paneth cells (1.89-fold), and Bcl2 level (1.54-fold). It countered radiation induced increases in cryptal apoptotic cells (1.64-fold) and Bax levels (1.88-fold). It also countered radiation (2 Gy and 3 Gy) induced bone marrow apoptosis (1.59-fold and 1.85-fold) and micronuclei frequency (1.72-fold and 2.6-fold). SBL-1 rendered radiation protection by promoting cryptal stem cells proliferation, by regulating apoptosis, and by countering radiation induced chromosomal damage. Quercetin, Ellagic acid, Gallic acid, high contents polyphenols, tannins, and thiols detected in SBL-1 may have contributed to radiation protection by neutralization of radiation induced oxidative species, supporting stem cell proliferation and tissue regeneration. PMID:26421051

  17. Radiation measurement above the lunar surface by Kaguya gamma-ray spectrometer

    NASA Astrophysics Data System (ADS)

    Hasebe, Nobuyuki; Nagaoka, Hiroshi; Kusano, Hiroki; Hareyama, Matoko; Ideguchi, Yusuke; Shimizu, Sota; Shibamura, Eido

    The lunar surface is filled with various ionizing radiations such as high energy galactic particles, albedo particles and secondary radiations of neutrons, gamma rays and other elementary particles. A high-resolution Kaguya Gamma-Ray Spectrometer (KGRS) was carried on the Japan’s lunar explorer SELENE (Kaguya), the largest lunar orbiter since the Apollo missions. The KGRS instrument employed, for the first time in lunar exploration, a high-purity Ge crystal to increase the identification capability of elemental gamma-ray lines. The Ge detector is surrounded by BGO and plastic counters as for anticoincidence shields. The KGRS measured gamma rays in the energy range from 200 keV to 13 MeV with high precision to determine the chemical composition of the lunar surface. It provided data on the abundance of major elements over the entire lunar surface. In addition to the gamma-ray observation by the KGRS, it successfully measured the global distribution of fast neutrons. In the energy spectra of gamma-rays observed by the KGRS, several saw-tooth- peaks of Ge are included, which are formed by the collision interaction of lunar fast neutrons with Ge atoms in the Ge crystal. With these saw-tooth-peaks analysis, global distribution of neutrons emitted from the lunara surface was successfully created, which was compared with the previous results obtained by Lunar Prospector neutron maps. Another anticoincidence counter, the plastic counter with 5 mm thickness, was used to veto radiation events mostly generated by charged particles. A single photomultiplier serves to count scintillation light from the plastic scintillation counter. The global map of counting rates observed by the plastic counter was also created, implying that the radiation counting rate implies the geological distribution, in spite that the plastic counter mostly measures high energy charged particles and energetic neutrons. These results are presented and discussed.

  18. 3He and BF 3 neutron detector pressure effect and model comparison

    NASA Astrophysics Data System (ADS)

    Lintereur, Azaree; Conlin, Kenneth; Ely, James; Erikson, Luke; Kouzes, Richard; Siciliano, Edward; Stromswold, David; Woodring, Mitchell

    2011-10-01

    Radiation detection systems for homeland security applications must possess the capability of detecting both gamma rays and neutrons. The radiation portal monitor systems that are currently deployed use a plastic scintillator for detecting gamma rays and 3He gas-filled proportional counters for detecting neutrons. Proportional counters filled with 3He are the preferred neutron detectors for use in radiation portal monitor systems because 3He has a large neutron cross-section, is relatively insensitive to gamma-rays, is neither toxic nor corrosive, can withstand extreme environments, and can be operated at a lower voltage than some of the alternative proportional counters. The amount of 3He required for homeland security and science applications has depleted the world supply and there is no longer enough available to fill the demand. Thus, alternative neutron detectors are being explored. Two possible temporary solutions that could be utilized while a more permanent solution is being identified are reducing the 3He pressure in the proportional counters and using boron trifluoride gas-filled proportional counters. Reducing the amount of 3He required in each of the proportional counters would decrease the rate at which 3He is being used; not enough to solve the shortage, but perhaps enough to increase the amount of time available to find a working replacement. Boron trifluoride is not appropriate for all situations as these detectors are less sensitive than 3He, boron trifluoride gas is corrosive, and a much higher voltage is required than what is used with 3He detectors. Measurements of the neutron detection efficiency of 3He and boron trifluoride as a function of tube pressure were made. The experimental results were also used to validate models of the radiation portal monitor systems.

  19. Process and apparatus for detecting presence of plant substances

    DOEpatents

    Kirby, John A.

    1991-01-01

    An apparatus and process for detecting the presence of plant substances in a particular environment which comprises the steps of: measuring the background K40 gamma ray radiation level in a particular environment with a 1.46 MeV gamma ray counter system; measuring the amount of K40 gamma ray radiation emanating from a package containing a plant substance being passed through an environment with a counter; and generating an alarm signal when the total K40 gamma ray radiation reaches a predetermined level over and above the background level.

  20. Radiation Counters

    DOEpatents

    Simpson, Jr, J A

    1950-01-31

    Geiger-Mueller and proportional counters operating at low potentials (about 125-300 v) obtained by utilizing certain ratios of diameters of the electrodes and particular mixtures of noble gases as the ionizing medium are covered in this application.

  1. DOSIMETRIC MEASUREMENTS ON THE SECOND SOVIET SPACESHIP SATELLITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savenko, I.A.; Pisarenko, N.F.; Shavrin, P.I.

    1963-02-01

    Readings of counters placed inside Sputnik II are given for one portion of its trajectory. The readings were taken by a gas-discharge counter STS-5 and a NaI crystal scintillator counter that registered gamma quanta, charged particles with a 25-kev counting threshold, and the aggregate energy liberation of ionizing radiations in the crystal. (C.E.S.)

  2. RADIATION COUNTER

    DOEpatents

    Goldsworthy, W.W.

    1958-02-01

    This patent relates to a radiation counter, and more particularly, to a scintillation counter having high uniform sensitivity over a wide area and capable of measuring alpha, beta, and gamma contamination over wide energy ranges, for use in quickly checking the contami-nation of personnel. Several photomultiplier tubes are disposed in parallel relationship with a light tight housing behind a wall of scintillation material. Mounted within the housing with the photomultipliers are circuit means for producing an audible sound for each pulse detected, and a range selector developing a voltage proportional to the repetition rate of the detected pulses and automatically altering its time constant when the voltage reaches a predetermined value, so that manual range adjustment of associated metering means is not required.

  3. A STUDY OF VARIOUS RADIATIONS DURING SPACE FLIGHTS OF SPUTNIKS, SPACE SHIPS AND ROCKETS (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vakulov, P.V.; Vernov, S.N.; Gorchakov, E.V.

    1962-06-01

    Data are presented on various radiation zones observed during the flights of the 3rd sputnik (launched May 15th, ship (Aug. 19 to 20, 1960, 339 km apogee and a 306 km perigee), the 3rd space ship (Dec. 1 to 2, 1960, 265 km apogee and a 187.3 km perigee), and the space rocket launched toward Venus on Feb. 12th, 1961. A radiation belt of electrons was detected at a height of 320 km above the earth's surface from the bremsstrahlung radiation determined on Geiger- Mueller and scintillation counters. Conjugate zones in the Northern hemisphere were linked with corresponding zones inmore » the Southern hemisphere. The position of the electron belt has remained relatively constant for about two years. The electron spectrum does not vary significantly. A count rate of >3.6 counts cm/ sup -2/ sec/sup -1/ was obtained in a Geiger-Mueller counter in the South Atlantic Ocean off the coast of Brazil. This high count rate was due to a magnetic anomaly in this region. An accurate distribution of cosmic ray intensity as a function of latitute was obtained from a comparison of the counts of the scintillation counter and the count of the STS-5 gas-discharge counter. Thirty references are included. (TTT)« less

  4. Network Algorithms for Detection of Radiation Sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, Nageswara S; Brooks, Richard R; Wu, Qishi

    In support of national defense, Domestic Nuclear Detection Office s (DNDO) Intelligent Radiation Sensor Systems (IRSS) program supported the development of networks of radiation counters for detecting, localizing and identifying low-level, hazardous radiation sources. Industry teams developed the first generation of such networks with tens of counters, and demonstrated several of their capabilities in indoor and outdoor characterization tests. Subsequently, these test measurements have been used in algorithm replays using various sub-networks of counters. Test measurements combined with algorithm outputs are used to extract Key Measurements and Benchmark (KMB) datasets. We present two selective analyses of these datasets: (a) amore » notional border monitoring scenario that highlights the benefits of a network of counters compared to individual detectors, and (b) new insights into the Sequential Probability Ratio Test (SPRT) detection method, which lead to its adaptations for improved detection. Using KMB datasets from an outdoor test, we construct a notional border monitoring scenario, wherein twelve 2 *2 NaI detectors are deployed on the periphery of 21*21meter square region. A Cs-137 (175 uCi) source is moved across this region, starting several meters from outside and finally moving away. The measurements from individual counters and the network were processed using replays of a particle filter algorithm developed under IRSS program. The algorithm outputs from KMB datasets clearly illustrate the benefits of combining measurements from all networked counters: the source was detected before it entered the region, during its trajectory inside, and until it moved several meters away. When individual counters are used for detection, the source was detected for much shorter durations, and sometimes was missed in the interior region. The application of SPRT for detecting radiation sources requires choosing the detection threshold, which in turn requires a source strength estimate, typically specified as a multiplier of the background radiation level. A judicious selection of this source multiplier is essential to achieve optimal detection probability at a specified false alarm rate. Typically, this threshold is chosen from the Receiver Operating Characteristic (ROC) by varying the source multiplier estimate. ROC is expected to have a monotonically increasing profile between the detection probability and false alarm rate. We derived ROCs for multiple indoor tests using KMB datasets, which revealed an unexpected loop shape: as the multiplier increases, detection probability and false alarm rate both increase until a limit, and then both contract. Consequently, two detection probabilities correspond to the same false alarm rate, and the higher is achieved at a lower multiplier, which is the desired operating point. Using the Chebyshev s inequality we analytically confirm this shape. Then, we present two improved network-SPRT methods by (a) using the threshold off-set as a weighting factor for the binary decisions from individual detectors in a weighted majority voting fusion rule, and (b) applying a composite SPRT derived using measurements from all counters.« less

  5. MEASUREMENT OF THE ABSORBED RADIATION DOSE ON THE THIRD SOVIET SATELLITE SPACESHIP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savenko, I.A.; Pisarenko, N.F.; Shavrin, P.I.

    1963-05-01

    The data obtained from two scintillation counters and one gas-discharge counter aboard the third Soviet satellite were reported. The main result is the conclusion that there is practically no danger in space flight at heights less than 350 km over a considerable period of time, in the absence of solar flares. A comparison of the data obtained on the second and third satellite permit practical inferences on radiation danger at greater heights as well. (C.E.S.)

  6. Design of a portable dose rate detector based on a double Geiger-Mueller counter

    NASA Astrophysics Data System (ADS)

    Wang, Peng; Tang, Xiao-Bin; Gong, Pin; Huang, Xi; Wen, Liang-Sheng; Han, Zhen-Yang; He, Jian-Ping

    2018-01-01

    A portable dose rate detector was designed to monitor radioactive pollution and radioactive environments. The portable dose detector can measure background radiation levels (0.1 μSv/h) to nuclear accident radiation levels (>10 Sv/h). Both automatic switch technology of a double Geiger-Mueller counter and time-to-count technology were adopted to broaden the measurement range of the instrument. Global positioning systems and the 3G telecommunication protocol were installed to prevent radiation damage to the human body. In addition, the Monte Carlo N-Particle code was used to design the thin layer of metal for energy compensation, which was used to flatten energy response The portable dose rate detector has been calibrated by the standard radiation field method, and it can be used alone or in combination with additional radiation detectors.

  7. EFFECT OF CHERENKOV LIGHT POLARIZATION ON TOTAL REFLECTION COUNTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dowell, J.D.; Duteil, P.; Leontic, B.

    1963-01-01

    A rugged total internal reflection counter with a 3- to 5cm thick compact radiator was used at the CERN proton synchrotron for beam analysis. The threshold behavior of this counter was compared when filled with glycerol and with turpentine. Turpentine is optically active and rotates the plane of polarization about 7 un. Concent 85% /cm. Figures illustrate the effect of this polarization rotation. (A.G.W.)

  8. Report: EPA Plans for Managing Counter Terrorism/ Emergency Response Equipment and Protecting Critical Assets Not Fully Implemented

    EPA Pesticide Factsheets

    Report #09-P-0087, January 27, 2009. EPA has progressed in implementing the counter terrorism/emergency response (CT/ER) initiatives, but is behind schedule in implementing the Radiation Ambient Monitoring (RadNet) System.

  9. The development of practice manual for LSC based on job analysis in radiation measurement and analysis

    NASA Astrophysics Data System (ADS)

    Shin, W. H.; Park, T. J.

    2017-06-01

    Radiation technology is closely related to the industrial growth and the creation of employment in Korea. The techniques as radiation or/and radioactivity measurement, and the practical skills achieving a higher level analysis are required. In this study, practice manual for liquid scintillation counter were developed by job analysis. Raw data applied in job analysis are collected by on/off line survey by 420 workers employed in KOREA. Importance-priority analysis was performed to make duties and competency unit that consists of knowledge, skills as each task. Refined data was reviewed by expert who experienced actual duties on site. Classification was conducted by focus group interview to deduct duties and competency unit. From the radiation devices in measurement and analysis, liquid scintillation counter was preferentially selected because of the high demands for training. Investigation of build-up status to liquid scintillation counter in KOREA was conducted. Then technical specification and operating procedure of 2 main devices were analyzed and integrated by practice manual. Duties and competency unit were applied to integrated materials respectively. To validate effectiveness, test curriculum was designed by the advanced course to workers who engaged in radiation measurement and analysis. The developed manual is structured to take advantage of test training. This manual will be a practical handbook that can improve the knowledge, skills of radiation workers in Korea.

  10. RADIATION HAZARD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Savenko, I.A.; Pisarenko, N.F.; Shavrin, P.I.

    1961-01-01

    Analysis of data obtained by Sputnik V (August 19, 1961) at about 320 km made it possible to delineate the position of the radiation belts and to estimate the amount of radiation hazard present. Scintillation counter data show that the radiation in the belts is anisotropic and that the energy flux under a layer of matter of 2 x 10/sup -3/ g cm/sup -2/ is 10/sup 10/ ev cm/sup -2/ sec/sup -1/. The mean energy released per quantum in the scintillation counter crystal is computed at 2.0 x 10/sup 5/ ev and the intensity of electrons in the outer beltmore » at 5 x 10/sup 4/ particles cm/sup -2/ sec/sup -1/. The radiation dosage absorbed inside Sputnik V was determined by dividing the amount of energy liberated in the sodium iodide crystal of the scinitillation counter by the weight of the crystal (36.4 g) without the need of a detailed examination of the composition and spectrum of the radiation. A dosage value of 7 mrad/24 hr was obtained; in terms of the RBE (relative biological effect) of the cosmic charged particles this amounted to 5O mrem/24 hr. This dosage is considered relatively safe for astronauts during flights along trajectories similar to that of Sputnik V when the sun is quiet. Solar flares, however, could bring about an increase in radiation. Owing to latitude and longitude effects and the specifi distribution of radiation at this height, the dosage per orbit ranged from 0.35 to 0.70 mrad. (OTS)« less

  11. Novel concept for neutron detection: proportional counter filled with 10B nanoparticle aerosol

    NASA Astrophysics Data System (ADS)

    Amaro, F. D.; Monteiro, C. M. B.; Dos Santos, J. M. F.; Antognini, A.

    2017-02-01

    The high neutron detection efficiency, good gamma-ray discrimination and non-toxicity of 3He made of proportional counters filled with this gas the obvious choice for neutron detection, particularly in radiation portal monitors (RPM), used to control the illicit transport of nuclear material, of which neutron detectors are key components. 3He is very rare and during the last decade this gas has become increasingly difficult to acquire. With the exception of BF3, which is toxic, no other gas can be used for neutron detection in proportional counters. We present an alternative where the 3He atoms are replaced by nanoparticles made of another neutron sensitive material, 10B. The particles are dispersed in a gaseous volume, forming an aerosol with neutron sensitive properties. A proportional counter filled with such aerosol was exposed to a thermal neutron beam and the recorded response indicates that the neutrons have interacted with the particles in the aerosol. This original technique, which transforms a standard proportional gas mixture into a neutron sensitive aerosol, is a breakthrough in the field of radiation detection and has the potential to become an alternative to the use of 3He in proportional counters.

  12. Experimental validation of a coupled neutron-photon inverse radiation transport solver

    NASA Astrophysics Data System (ADS)

    Mattingly, John; Mitchell, Dean J.; Harding, Lee T.

    2011-10-01

    Sandia National Laboratories has developed an inverse radiation transport solver that applies nonlinear regression to coupled neutron-photon deterministic transport models. The inverse solver uses nonlinear regression to fit a radiation transport model to gamma spectrometry and neutron multiplicity counting measurements. The subject of this paper is the experimental validation of that solver. This paper describes a series of experiments conducted with a 4.5 kg sphere of α-phase, weapons-grade plutonium. The source was measured bare and reflected by high-density polyethylene (HDPE) spherical shells with total thicknesses between 1.27 and 15.24 cm. Neutron and photon emissions from the source were measured using three instruments: a gross neutron counter, a portable neutron multiplicity counter, and a high-resolution gamma spectrometer. These measurements were used as input to the inverse radiation transport solver to evaluate the solver's ability to correctly infer the configuration of the source from its measured radiation signatures.

  13. Radiation effects on ALICE V0 detector components

    NASA Astrophysics Data System (ADS)

    Cheynis, B.; Ducroux, L.; Grossiord, J.-Y.; Guichard, A.; Pillot, P.; Rapp, B.; Tieulent, R.; Tromeur, W.; Zoccarato, Y.

    2006-12-01

    The 60 MeV proton beam delivered by the RADEF facility of the University of Jyväskylä (Finland) was used to measure the radiation effects on the counter components of the V0 detector of ALICE. There are the scintillator BC404, the wavelength shifting fibres BCF9929A and the optical fibres BCF98 from Bicron (Saint-Gobain). The light yield and the time resolution given by a counter of the inner ring of the V0C array, mounted within a dedicated device, were measured as a function of the radiation dose up to about 300 krad. A global light attenuation of the order of 30% can be anticipated during 10 years of ALICE running.

  14. PHOTON STUDY WITH SPUTNIK III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chudakov, A.E.

    1961-01-01

    >A scintillation counter with twice the efficiency of a Geiger counter for photon recording was placed in the third Soviet satellite. The counter consisted of a cylindrical crystal of sodium iodide and a photomuitiplier. It was found that the total ionization in the crystal was much greater than expected. This excess seemed to depend on geomagnetic longitude as well as latitude. The most probable explanation is the bremsstrahlung radiation of electrons of energy less than 100 kev. (L.N.N.)

  15. LOW LEVEL COUNTING TECHNIQUES WITH SPECIAL REFERENCE TO BIOMEDICAL TRACER PROBLEMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, F.; Nag, B.D.

    1959-12-01

    Low-level counting techniques in tracer experiments are discussed with emphasis on the measurement of beta and gamma radiations with Geiger and scintillation counting methods. The basic principles of low-level counting are outlined. Screen-wall counters, internal gas counters, low-level beta counters, scintillation spectrometers, liquid scintillators, and big scintillation installations are described. Biomedical tracer investigations are discussed. Applications of low-level techniques in archaeological dating, biology, and other problems are listed. (M.C.G.)

  16. Study of the response of a lithium yttrium borate scintillator based neutron rem counter by Monte Carlo radiation transport simulations

    NASA Astrophysics Data System (ADS)

    Sunil, C.; Tyagi, Mohit; Biju, K.; Shanbhag, A. A.; Bandyopadhyay, T.

    2015-12-01

    The scarcity and the high cost of 3He has spurred the use of various detectors for neutron monitoring. A new lithium yttrium borate scintillator developed in BARC has been studied for its use in a neutron rem counter. The scintillator is made of natural lithium and boron, and the yield of reaction products that will generate a signal in a real time detector has been studied by FLUKA Monte Carlo radiation transport code. A 2 cm lead introduced to enhance the gamma rejection shows no appreciable change in the shape of the fluence response or in the yield of reaction products. The fluence response when normalized at the average energy of an Am-Be neutron source shows promise of being used as rem counter.

  17. Radiation Monitor,IV-TEPC

    NASA Image and Video Library

    2012-12-30

    View of radiation monitor,Intra-Vehicular Tissue Equivalent Proportional Counter (IV-TEPC),relocated to NOD2 P3,Part Number (P/N): SEG33120960-301,Serial Number (S/N): 1002,in the Node 2. Photo was taken during Expedition 34.

  18. PLASMA EMISSION BY COUNTER-STREAMING ELECTRON BEAMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ziebell, L. F.; Petruzzellis, L. T.; Gaelzer, R.

    2016-02-10

    The radiation emission mechanism responsible for both type-II and type-III solar radio bursts is commonly accepted as plasma emission. Recently Ganse et al. suggested that type-II radio bursts may be enhanced when the electron foreshock geometry of a coronal mass ejection contains a double hump structure. They reasoned that the counter-streaming electron beams that exist between the double shocks may enhance the nonlinear coalescence interaction, thereby giving rise to more efficient generation of radiation. Ganse et al. employed a particle-in-cell simulation to study such a scenario. The present paper revisits the same problem with EM weak turbulence theory, and showmore » that the fundamental (F) emission is not greatly affected by the presence of counter-streaming beams, but the harmonic (H) emission becomes somewhat more effective when the two beams are present. The present finding is thus complementary to the work by Ganse et al.« less

  19. PULSE COUNTER

    DOEpatents

    Trumbo, D.E.

    1959-02-10

    A transistorized pulse-counting circuit adapted for use with nuclear radiation detecting detecting devices to provide a small, light weight portable counter is reported. The small size and low power requirements of the transistor are of particular value in this instance. The circuit provides an adjustable count scale with a single transistor which is triggered by the accumulated charge on a storage capacitor.

  20. Radiation dose-rate meter using an energy-sensitive counter

    DOEpatents

    Kopp, Manfred K.

    1988-01-01

    A radiation dose-rate meter is provided which uses an energy-sensitive detector and combines charge quantization and pulse-rate measurement to monitor radiation dose rates. The charge from each detected photon is quantized by level-sensitive comparators so that the resulting total output pulse rate is proportional to the dose-rate.

  1. Radiative neutron capture as a counting technique at pulsed spallation neutron sources: a review of current progress

    NASA Astrophysics Data System (ADS)

    Schooneveld, E. M.; Pietropaolo, A.; Andreani, C.; Perelli Cippo, E.; Rhodes, N. J.; Senesi, R.; Tardocchi, M.; Gorini, G.

    2016-09-01

    Neutron scattering techniques are attracting an increasing interest from scientists in various research fields, ranging from physics and chemistry to biology and archaeometry. The success of these neutron scattering applications is stimulated by the development of higher performance instrumentation. The development of new techniques and concepts, including radiative capture based neutron detection, is therefore a key issue to be addressed. Radiative capture based neutron detectors utilize the emission of prompt gamma rays after neutron absorption in a suitable isotope and the detection of those gammas by a photon counter. They can be used as simple counters in the thermal region and (simultaneously) as energy selector and counters for neutrons in the eV energy region. Several years of extensive development have made eV neutron spectrometers operating in the so-called resonance detector spectrometer (RDS) configuration outperform their conventional counterparts. In fact, the VESUVIO spectrometer, a flagship instrument at ISIS serving a continuous user programme for eV inelastic neutron spectroscopy measurements, is operating in the RDS configuration since 2007. In this review, we discuss the physical mechanism underlying the RDS configuration and the development of associated instrumentation. A few successful neutron scattering experiments that utilize the radiative capture counting techniques will be presented together with the potential of this technique for thermal neutron diffraction measurements. We also outline possible improvements and future perspectives for radiative capture based neutron detectors in neutron scattering application at pulsed neutron sources.

  2. High energy neutron dosimeter

    DOEpatents

    Sun, Rai Ko S.F.

    1994-01-01

    A device for measuring dose equivalents in neutron radiation fields. The device includes nested symmetrical hemispheres (forming spheres) of different neutron moderating materials that allow the measurement of dose equivalents from 0.025 eV to past 1 GeV. The layers of moderating material surround a spherical neutron counter. The neutron counter is connected by an electrical cable to an electrical sensing means which interprets the signal from the neutron counter in the center of the moderating spheres. The spherical shape of the device allows for accurate measurement of dose equivalents regardless of its positioning.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Progress is reported in studies on the metabolism, radiation dose, radiation effects, and toxic effects of prolonged expesure of dogs following injection of various doses 8/, Th/sup 228, and Sr/sup 90/ An imporved live dog gamma counter is described. (For preceding period see AECU 3522.) (C.H.)

  4. Characterization of Sphinx1 ASIC X-ray detector using photon counting and charge integration

    NASA Astrophysics Data System (ADS)

    Habib, A.; Arques, M.; Moro, J.-L.; Accensi, M.; Stanchina, S.; Dupont, B.; Rohr, P.; Sicard, G.; Tchagaspanian, M.; Verger, L.

    2018-01-01

    Sphinx1 is a novel pixel architecture adapted for X-ray imaging, it detects radiation by photon counting and charge integration. In photon counting mode, each photon is compensated by one or more counter-charges typically consisting of 100 electrons (e-) each. The number of counter-charges required gives a measure of the incoming photon energy, thus allowing spectrometric detection. Pixels can also detect radiation by integrating the charges deposited by all incoming photons during one image frame and converting this analog value into a digital response with a 100 electrons least significant bit (LSB), based on the counter-charge concept. A proof of concept test chip measuring 5 mm × 5 mm, with 200 μm × 200 μm pixels has been produced and characterized. This paper provides details on the architecture and the counter-charge design; it also describes the two modes of operation: photon counting and charge integration. The first performance measurements for this test chip are presented. Noise was found to be ~80 e-rms in photon counting mode with a power consumption of only 0.9 μW/pixel for the static analog part and 0.3 μW/pixel for the static digital part.

  5. Nuclear Science Symposium, 21st, Scintillation and Semiconductor Counter Symposium, 14th, and Nuclear Power Systems Symposium, 6th, Washington, D.C., December 11-13, 1974, Proceedings

    NASA Technical Reports Server (NTRS)

    1975-01-01

    Papers are presented dealing with latest advances in the design of scintillation counters, semiconductor radiation detectors, gas and position sensitive radiation detectors, and the application of these detectors in biomedicine, satellite instrumentation, and environmental and reactor instrumentation. Some of the topics covered include entopistic scintillators, neutron spectrometry by diamond detector for nuclear radiation, the spherical drift chamber for X-ray imaging applications, CdTe detectors in radioimmunoassay analysis, CAMAC and NIM systems in the space program, a closed loop threshold calibrator for pulse height discriminators, an oriented graphite X-ray diffraction telescope, design of a continuous digital-output environmental radon monitor, and the optimization of nanosecond fission ion chambers for reactor physics. Individual items are announced in this issue.

  6. Radiation and Health: A Workshop for Science Educators

    NASA Astrophysics Data System (ADS)

    Krieger, Kenneth

    2010-03-01

    This workshop covers nuclear science and technology topics suitable for science teachers to use in grade 4-12 classes. Subjects included are Fundamentals of Radiation, Exposure to natural and man- made Radiation, Cellular Biology and Radiation Effects, Radioactive Waste Management, Health Physics and Radiation Physics, and Career possibilities in Nuclear Technology. Schools of participants will receive a working Geiger Counter. Workshop presenter is a TEA-approved CPE Provider. Limited to 20 participants - 3 hours - Cost 2.00

  7. High energy neutron dosimeter

    DOEpatents

    Rai, K.S.F.

    1994-01-11

    A device for measuring dose equivalents in neutron radiation fields is described. The device includes nested symmetrical hemispheres (forming spheres) of different neutron moderating materials that allow the measurement of dose equivalents from 0.025 eV to past 1 GeV. The layers of moderating material surround a spherical neutron counter. The neutron counter is connected by an electrical cable to an electrical sensing means which interprets the signal from the neutron counter in the center of the moderating spheres. The spherical shape of the device allows for accurate measurement of dose equivalents regardless of its positioning. 2 figures.

  8. A sealed titanium window proportional counter for the detection of .5-keV X rays.

    NASA Technical Reports Server (NTRS)

    Mcclintock, J. E.; Levine, A.; Rappaport, S.

    1972-01-01

    A sealed Ti window proportional counter sensitive to X radiation in the energy range 0.35-0.45 keV and above 1.5 keV is described. Measurements of the Ti mass absorption coefficients and a graphical summary of the literature values are presented. For a proportional counter with a 930 microgram/sq cm (2.1-micron) Ti window, the peak efficiency at 0.45 keV is found to lie between 4.6% and 7.1%. An application in X-ray astronomy involving a rocket observation of Sco X-1 is discussed.

  9. Gold nanoparticle decorated multi-walled carbon nanotubes as counter electrode for dye sensitized solar cells.

    PubMed

    Kaniyoor, Adarsh; Ramaprabhu, Sundara

    2012-11-01

    A novel counter electrode material for dye sensitized solar cells (DSSCs) composed of nanostructured Au particles decorated on functionalized multi-walled carbon nanotubes (f-MWNTs) is demonstrated for the first time. MWNTs synthesized by catalytic chemical vapor deposition technique are purified and functionalized by treating with concentrated acids. Au nanoparticles are decorated on f-MWNTs by a rapid and facile microwave assisted polyol reduction method. The materials are characterized by X-ray diffractometry, Fourier transform infra red spectroscopy and electron microscopy. The DSSC fabricated with Au/f-MWNTs based counter electrode shows enhanced power conversion efficiency (eta) of 4.9% under AM 1.5G simulated solar radiation. In comparison, the reference DSSCs fabricated with f-MWNTs and Pt counter electrodes show eta of 2.1% and 4.5%. This high performance of Au/f-MWNTs counter electrode is investigated using electrochemical impedance spectroscopy and cyclic voltammetry studies.

  10. X-ray astronomy instrumentation studies. [design of a proportional counter and measurements of fluorescent radiation

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1981-01-01

    Preliminary designs were made for a multiplane, multiwire position sensitive proportional counter for X-ray use. Anode spacing was 2 mm and cathode spacing 1 mm. Assistance was provided in setting up and operating two multiwire proportional counters, one with 5 mm anode spacing, and the other with 2 mm spacing. Argon-based counter gases were used for preliminary work in assembling a working experimental system to measure xenon fluorescence yields. The design and specification of a high purity gas filling system capable of supplying mixtures of xenon and other gases to proportional counters was also performed. The system is mounted on a cart, is fully operational, and is flexible enough to be easily used as a pumping station for other clean applications. When needed, assistance was given to put into operation various computer-related pieces of equipment.

  11. MICRODOSIMETRIC MEASUREMENT OF SECONDARY RADIATION IN THE PASSIVE SCATTERED PROTON THERAPY ROOM OF iTHEMBA LABS USING A TISSUE-EQUIVALENT PROPORTIONAL COUNTER.

    PubMed

    Chiriotti, S; Parisi, A; Vanhavere, F; De Saint-Hubert, M; Vandevoorde, C; Slabbert, J; Beukes, P; de Kock, E; Symons, J

    2018-04-13

    Measurements of the dose equivalent at different distances from the isocenter of the proton therapy center at iThemba LABS were previously performed with a tissue-equivalent proportional counter (TEPC). These measurements showed that the scattered radiation levels were one or two orders of magnitude higher in comparison to other passive scattering delivery systems. In order to reduce these radiation levels, additional shielding was installed shortly after the measurements were done. Therefore, the aim of this work is to quantify and assess the reduction of the secondary doses delivered in the proton therapy room at iThemba LABS after the installation of the additional shielding. This has been performed by measuring microdosimetric spectra with a TEPC at 11 locations around the isocenter when a clinical modulated beam of 200 MeV proton was impinging onto a water phantom placed at the isocenter.

  12. Doppler radar flowmeter

    DOEpatents

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  13. Experimental study of the effects of installation on singleand counter-rotation propeller noise

    NASA Technical Reports Server (NTRS)

    Block, P. J. W.

    1986-01-01

    Measurements which are required to define the directivity and the level of propeller noise were studied. The noise radiation pattern for various single-rotation (SR) propeller and counter-rotation (CR) propeller installations were mapped. The measurements covered + or - 60 deg from the propeller disk plane and + or - 60 deg in the cross-stream direction. Configurations examined included SR and CR propellers at angle of attack and an SR pusher installation. The increases in noise that arise from an unsteady loading operation such as an SR pusher or a CR exceeded 15 dB in the forward axial direction. Most of the additional noise radiates in the axial directions for unsteady loading operations of both the SR pusher and the CR tractor.

  14. Radiation-Hardened Solid-State Drive

    NASA Technical Reports Server (NTRS)

    Sheldon, Douglas J.

    2010-01-01

    A method is provided for a radiationhardened (rad-hard) solid-state drive for space mission memory applications by combining rad-hard and commercial off-the-shelf (COTS) non-volatile memories (NVMs) into a hybrid architecture. The architecture is controlled by a rad-hard ASIC (application specific integrated circuit) or a FPGA (field programmable gate array). Specific error handling and data management protocols are developed for use in a rad-hard environment. The rad-hard memories are smaller in overall memory density, but are used to control and manage radiation-induced errors in the main, and much larger density, non-rad-hard COTS memory devices. Small amounts of rad-hard memory are used as error buffers and temporary caches for radiation-induced errors in the large COTS memories. The rad-hard ASIC/FPGA implements a variety of error-handling protocols to manage these radiation-induced errors. The large COTS memory is triplicated for protection, and CRC-based counters are calculated for sub-areas in each COTS NVM array. These counters are stored in the rad-hard non-volatile memory. Through monitoring, rewriting, regeneration, triplication, and long-term storage, radiation-induced errors in the large NV memory are managed. The rad-hard ASIC/FPGA also interfaces with the external computer buses.

  15. Radiation biodosimetry: applications for spaceflight

    NASA Astrophysics Data System (ADS)

    Blakely, W.; Miller, A.; Grace, M.; Prasanna, P.; Muderhwa, J.

    The multiparametric dosimetry system that we are developing for medical radiological defense applications could be adapted for spaceflight environments. The system complements the internationally accepted cytogenetic analysis of chromosome aberrations, considered the best means of documenting radiation doses for health records. Our system consists of a dose assessment software application, a portable blood cell counter, and molecular biodosimetry using miniaturized equipment. The Biodosimetry Assessment Tool (BAT) software application calculates radiation dose based on a patient's physical signs and symptoms and blood analysis, annotates location of personnel dosimeters, displays a summary of a patient's dosimetric information to healthcare professionals, and archives the data for further use. The dry reagent centrifuge-based blood cell counter (QBC Autoread Plus, Beckon Dickinson Bioscience) measures peripheral blood lymphocytes and monocytes, which could determine radiation dose based on the kinetics of blood cell depletion. Molecular biomarkers for ionizing radiation exposure (gene expression changes, blood proteins), once dose-dependent targets are identified, optimized, and validated, will make use of miniaturized diagnostic equipment for nucleic acid sequence and antigen-based biosensor detection technologies. These radiation assessment diagnostic technologies can have dual use for other medical related applications. [The Armed Forces Radiobiology Research Institute, under work unit AFRRI-01-3, and the Defense Threat Reduction Agency, under contract GG4661, supported this research.

  16. 76 FR 35672 - Revised Effectiveness Determination; Sunscreen Drug Products for Over-the-Counter Human Use

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-17

    ... are given ultraviolet (UV) radiation doses produced by a solar simulator (i.e., a UV lamp). Under... increasingly higher UV doses produced by the solar simulator. However, because the solar simulator can produce far higher UV radiation doses than a consumer would ever receive even under the most severe sun...

  17. A radionuclide counting technique for measuring wind velocity. [drag force anemometers

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Khandelwal, G. S.; Mall, G. H.

    1981-01-01

    A technique for measuring wind velocities of meteorological interest is described. It is based on inverse-square-law variation of the counting rates as the radioactive source-to-counter distance is changed by wind drag on the source ball. Results of a feasibility study using a weak bismuth 207 radiation source and three Geiger-Muller radiation counters are reported. The use of the technique is not restricted to Martian or Mars-like environments. A description of the apparatus, typical results, and frequency response characteristics are included. A discussion of a double-pendulum arrangement is presented. Measurements reported herein indicate that the proposed technique may be suitable for measuring wind speeds up to 100 m/sec, which are either steady or whose rates of fluctuation are less than 1 kHz.

  18. Advances in solar and cosmic X-ray astronomy - A survey of experimental techniques and observational results.

    NASA Technical Reports Server (NTRS)

    Hoover, R. B.; Thomas, R. J.; Underwood, J. H.

    1972-01-01

    The current status of X-ray astronomy is surveyed by reviewing observational results and theoretical conclusions gained within the past two years in areas dealing with the quiet-sun, slowly-varying, and burst components of solar X-radiation and with the features of cosmic X-ray sources. Thermal and nonthermal processes responsible for a wide variety of X-ray emission mechanisms in nature are explained, and characteristics of X radiation from specific solar structures are described. Attention is given to the effects of interstellar and intergalactic matter on cosmic X-rays; the properties of galactic and extragalactic X-ray sources; and the specifications of such instruments as gas-filled ionization detectors, proportional counters, Geiger counters, scintillation detectors, photoelectric detectors, polarimeters, collimators, spectrometers, and imaging systems.

  19. RADIOMETRIC EQUIPMENT ON SECOND SPACESHIP-SATELLITE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Papkov, S.F.; Pisarenko, N.F.; Savenko, I.A.

    1961-01-01

    Equipment installed on the second Soviet spaceshipsatellite to measure radiation and determine dose absorption is described. A scintillation counter recorded charged particles penetrating the skin of the spaceship and gamma quanta with energies exceeding 25 kev. Two CTC-5 gas-discharge counters also recorded charged particles, and, as the efficiency of gamma recording was low (below 10/sup -2/), a comparison of readings made it possible to evaluate the contribution of the charged particles and the gamma quanta, respectively, to the absorbed dose. A separate scintillation counter measured the energy flow of relatively soft charged particles. Electronic equipment was supplied with energy frommore » a 6( plus or minus 1)-v battery with power not over 0.5 w. A thorough check of the spaceship after its return to earth demonstrated that all the counters and electronie devices had retained their efficiency. A block diagram of the equipment is given. (OTS)« less

  20. Wide-range radiation dose monitor

    DOEpatents

    Kopp, Manfred K.

    1986-01-01

    A radiation dose-rate monitor is provided which operates in a conventional linear mode for radiation in the 0 to 0.5 R/h range and utilizes a nonlinear mode of operation for sensing radiation from 0.5 R/h to over 500 R/h. The nonlinear mode is achieved by a feedback circuit which adjusts the high voltage bias of the proportional counter, and hence its gas gain, in accordance with the amount of radiation being monitored. This allows compression of readout onto a single scale over the range of 0 to greater than 500 R/h without scale switching operations.

  1. Wide-range radiation dose monitor

    DOEpatents

    Kopp, M.K.

    1984-09-20

    A radiation dose-rate monitor is provided which operates in a conventional linear mode for radiation in the 0 to 0.5 R/h range and utilizes a nonlinear mode of operation for sensing radiation from 0.5 R/h to over 500 R/h. The nonlinear mode is achieved by a feedback circuit which adjusts the high voltage bias of the proportional counter, and hence its gas gain, in accordance with the amount of radiation being monitored. This allows compression of readout onto a single scale over the range of 0 to greater than 500 R/h without scale switching operations.

  2. A bismuth activation counter for high sensitivity pulsed 14 MeV neutrons

    NASA Astrophysics Data System (ADS)

    Burns, E. J. T.; Thacher, P. D.; Hassig, G. J.; Decker, R. D.; Romero, J. A.; Barrett, K. P.

    2011-08-01

    We have built a fast neutron bismuth activation counter that measures activation counts from pulsed 14-MeV neutron generators for incident neutron fluences between 30 and 300 neutrons/cm2 at 15.2 cm (6 in.). The activation counter consists of a large bismuth germanate (BGO) detector surrounded by a bismuth metal shield in front of and concentric with the cylindrical detector housing. The 14 MeV neutrons activate the 2.6-millisecond (ms) isomer in the shield and the detector by the reaction 209Bi (n,2nγ) 208mBi. The use of millisecond isomers and activation counting times minimizes the background from other activated materials and the environment. In addition to activation, the bismuth metal shields against other outside radiation sources. We have tested the bismuth activation counter, simultaneously, with two data acquisition systems (DASs) and both give similar results. The two-dimensional (2D) DAS and three dimensional (3D) DAS both consist of pulse height analysis (PHA) systems that can be used to discriminate against gamma radiations below 300 keV photon energy, so that the detector can be used strictly as a counter. If the counting time is restricted to less than 25 ms after the neutron pulse, there are less than 10 counts of background for single pulse operation in all our operational environments tested so far. High-fluence neutron generator operations are restricted by large dead times and pulse height saturation. When we operate our 3D DAS PHA system in list mode acquisition (LIST), real-time corrections to dead time or live time can be made on the scale of 1 ms time windows or dwell times. The live time correction is consistent with nonparalyzable models for dead time of 1.0±0.2 μs for our 3D DAS and 1.5±0.3 μs for our 2D DAS dominated by our fixed time width analog to digital converters (ADCs). With the same solid angle, we have shown that the bismuth activation counter has a factor of 4 increase in sensitivity over our lead activation counter, because of higher counts and negligible backgrounds.

  3. A method for monitoring nuclear absorption coefficients of aviation fuels

    NASA Technical Reports Server (NTRS)

    Sprinkle, Danny R.; Shen, Chih-Ping

    1989-01-01

    A technique for monitoring variability in the nuclear absorption characteristics of aviation fuels has been developed. It is based on a highly collimated low energy gamma radiation source and a sodium iodide counter. The source and the counter assembly are separated by a geometrically well-defined test fuel cell. A computer program for determining the mass attenuation coefficient of the test fuel sample, based on the data acquired for a preset counting period, has been developed and tested on several types of aviation fuel.

  4. Search for 1/3e and 2/3e charged quarks in the cosmic radiation at 2750-m altitude.

    NASA Technical Reports Server (NTRS)

    Cox, A. J.; Beauchamp, W. T.; Bowen, T.; Kalbach, R. M.

    1972-01-01

    A scintillation counter telescope consisting of eight liquid scintillation counters and four wide-gap spark chambers was used to search for particles with electric charge 1/3e and 2/3e in cosmic rays at 2750 m above sea level. No such particles were detected during the 1500-hr experimental run. Upper limits on the vertical fluxes are established, and estimates of the corresponding sea-level fluxes are made for comparison with previous results.

  5. Position-sensitive proportional counter with low-resistance metal-wire anode

    DOEpatents

    Kopp, Manfred K.

    1980-01-01

    A position-sensitive proportional counter circuit is provided which allows the use of a conventional (low-resistance, metal-wire anode) proportional counter for spatial resolution of an ionizing event along the anode of the counter. A pair of specially designed active-capacitance preamplifiers are used to terminate the anode ends wherein the anode is treated as an RC line. The preamplifiers act as stabilized active capacitance loads and each is composed of a series-feedback, low-noise amplifier, a unity-gain, shunt-feedback amplifier whose output is connected through a feedback capacitor to the series-feedback amplifier input. The stabilized capacitance loading of the anode allows distributed RC-line position encoding and subsequent time difference decoding by sensing the difference in rise times of pulses at the anode ends where the difference is primarily in response to the distributed capacitance along the anode. This allows the use of lower resistance wire anodes for spatial radiation detection which simplifies the counter construction and handling of the anodes, and stabilizes the anode resistivity at high count rates (>10.sup.6 counts/sec).

  6. A standardized Hippophae extract (SBL-1) counters neuronal tissue injuries and changes in neurotransmitters: implications in radiation protection.

    PubMed

    Bala, Madhu; Gupta, Vanita; Prasad, Jagdish

    2017-12-01

    Effects of a radioprotective, standardized leaf extract (code SBL-1) from traditional medicinal plant, sea buckthorn [Hippophae rhamnoides L. (Elaeagnaceae)], on neurotransmitters and brain injuries in rats showing radiation-induced conditioned taste aversion (CTA), are not known. Understanding CTA in rats is important because its process is considered parallel to nausea and vomiting in humans. This study investigated the levels of neurotransmitters, antioxidant defences and histological changes in rats showing radiation CTA, and their modification by SBL-1. The inbred male Sprague-Dawley rats (age 65 days, weighing 190 ± 10 g) were used. Saccharin-preferring rats were selected using standard procedure and divided into groups. Group I (untreated control) was administered sterile water, group II was 60 Co-γ-irradiated (2 Gy), and group III was administered SBL-1 before irradiation. Observations were recorded up to day 5. Irradiation (2 Gy) caused (i) non-recoverable CTA (≥ 64.7 ± 5.0%); (ii) degenerative changes in cerebral cortex, amygdala and hippocampus; (iii) increases in brain dopamine (DA, 63.4%), norepinephrine (NE, 157%), epinephrine (E, 233%), plasma NE (103%) and E (160%); and (iv) decreases in brain superoxide dismutase (67%), catalase (60%) and glutathione (51%). SBL-1 treatment (12 mg/kg body weight) 30 min before irradiation (i) countered brain injuries, (ii) reduced CTA (38.7 ± 3.0%, day 1) and (iii) normalized brain DA, NE, E, superoxide dismutase, catalase and CTA from day 3 onwards. Radiation CTA was coupled with brain injuries, disturbances in neurotransmitters and antioxidant defences. SBL-1 pretreatment countered these disturbances, indicating neuroprotective action.

  7. Monte Carlo track structure for radiation biology and space applications

    NASA Technical Reports Server (NTRS)

    Nikjoo, H.; Uehara, S.; Khvostunov, I. G.; Cucinotta, F. A.; Wilson, W. E.; Goodhead, D. T.

    2001-01-01

    Over the past two decades event by event Monte Carlo track structure codes have increasingly been used for biophysical modelling and radiotherapy. Advent of these codes has helped to shed light on many aspects of microdosimetry and mechanism of damage by ionising radiation in the cell. These codes have continuously been modified to include new improved cross sections and computational techniques. This paper provides a summary of input data for ionizations, excitations and elastic scattering cross sections for event by event Monte Carlo track structure simulations for electrons and ions in the form of parametric equations, which makes it easy to reproduce the data. Stopping power and radial distribution of dose are presented for ions and compared with experimental data. A model is described for simulation of full slowing down of proton tracks in water in the range 1 keV to 1 MeV. Modelling and calculations are presented for the response of a TEPC proportional counter irradiated with 5 MeV alpha-particles. Distributions are presented for the wall and wall-less counters. Data shows contribution of indirect effects to the lineal energy distribution for the wall counters responses even at such a low ion energy.

  8. Development of the cosmic ray techniques

    NASA Technical Reports Server (NTRS)

    Rossi, B.

    1982-01-01

    It has been found that most advances of cosmic-ray physics have been directly related to the development of observational techniques. The history of observational techniques is discussed, taking into account ionization chambers, refinements applied to ionization chambers to make them suitable for an effective use in the study of cosmic radiation, the Wulf-type electrometer, the electrometer designed by Millikan and Neher, the Geiger-Mueller counter, the experiment of Bothe and Kolhoerster, the coincidence circuit, and a cosmic-ray 'telescope'. Attention is given to a magnetic lens for cosmic rays, a triangular arrangement of Geiger-Mueller counters used to demonstrate the production of a secondary radiation, a stereoscopic cloud-chamber photograph of showers, the cloud-chamber picture which provided the first evidence of the positive electron, and arrangements for studying photon components, mu-mesons, and air showers.

  9. A Study of Emergency Room Health CAre Providers and the Fixed Facility Physical Capabilities to Manage the Presenting Radiologically Injured Patient

    DTIC Science & Technology

    1984-08-01

    large areas 6. Contaminated hair 35 a. Shampoo with mild soap for three minutes and rinse b. Monitor and repeat step a as needed c. If contamination...M counters are generally used for surveying low-level radiation and are calibrated either in counts per minute (CPM) or milloroentgens per hours (mR... surveyed for contamination? Decontaminated D. Nature of accident: Type radiation source Other Details: E. Person in charge of radiation evaluation: F

  10. Particle Detectors

    NASA Astrophysics Data System (ADS)

    Grupen, Claus; Shwartz, Boris

    2011-09-01

    Preface to the first edition; Preface to the second edition; Introduction; 1. Interactions of particles and radiation with matter; 2. Characteristic properties of detectors; 3. Units of radiation measurements and radiation sources; 4. Accelerators; 5. Main physical phenomena used for particle detection and basic counter types; 6. Historical track detectors; 7. Track detectors; 8. Calorimetry; 9. Particle identification; 10. Neutrino detectors; 11. Momentum measurement and muon detection; 12. Ageing and radiation effects; 13. Example of a general-purpose detector: Belle; 14. Electronics; 15. Data analysis; 16. Applications of particle detectors outside particle physics; 17. Glossary; 18. Solutions; 19. Resumé; Appendixes; Index.

  11. Self-regulating neutron coincidence counter

    DOEpatents

    Baron, N.

    1980-06-16

    A device for accurately measuring the mass of /sup 240/Pu and /sup 239/Pu in a sample having arbitrary moderation and mixed with various contaminants. The device utilizes a thermal neutron well counter which has two concentric rings of neutron detectors separated by a moderating material surrounding the well. Neutron spectroscopic information derived by the two rings of detectors is used to measure the quantity of /sup 239/Pu and /sup 240/Pu in device which corrects for background radiation, deadtime losses of the detector and electronics and various other constants of the system.

  12. Social Sciences Support to Military Personnel Engaged in Counter-Insurgency and Counter-Terrorism Operations (Soutien en sciences sociales apporte au personnel militaire engage dans des operations de contre-insurrection et de contre-terrorisme)

    DTIC Science & Technology

    2011-11-01

    Aleksanin, M.D., Ph.D., Director of the Nikiforov Russian Centre of Emergency and Radiation Medicine: Dr. Aleksanin has worked as a therapist and served as a...four components of being combat ready: psychological health, physical health, combat skills and physical training. The combat potential of the...clear that participation in armed conflict affects mental and physical health adversely. Studies have shown that certain personality changes take

  13. A method for monitoring the variability in nuclear absorption characteristics of aviation fuels

    NASA Technical Reports Server (NTRS)

    Sprinkle, Danny R.; Shen, Chih-Ping

    1988-01-01

    A technique for monitoring variability in the nuclear absorption characteristics of aviation fuels has been developed. It is based on a highly collimated low energy gamma radiation source and a sodium iodide counter. The source and the counter assembly are separated by a geometrically well-defined test fuel cell. A computer program for determining the mass attenuation coefficient of the test fuel sample, based on the data acquired for a preset counting period, has been developed and tested on several types of aviation fuel.

  14. The effects of installation on single- and counter-rotation propeller noise

    NASA Technical Reports Server (NTRS)

    Block, P. J. W.

    1984-01-01

    In order to understand the effects of installation on propeller noise, numerous measurements are required to define the directivity of the noise as well as the level. An experimental study was designed to map the noise radiation pattern for various single-rotation propeller (SRP) and counter-rotation propeller (CRP) installations covering + or 60 deg from the propeller disk plane and + or - 60 deg laterally. Configurations that were considered included an SRP at angle of attack and in tractor and pusher operations and a CRP. A first principles linear theory was validated for the SRP tractor operation over the angle range mentioned above. The increases in noise that arise from an unsteady loading operation such as an SRP pusher or CRP exceed 15 dB and depend on the observer location. In particular, the majority of the additional noise appears to radiate in the axial directions.

  15. In-flight measured and predicted ambient dose equivalent and latitude differences on effective dose estimates.

    PubMed

    Saez Vergara, J C; Romero Gutiérrez, A M; Rodriguez Jiménez, R; Dominguez-Mompell Román, R

    2004-01-01

    The results from 2 years (2001-2002) of experimental measurements of in-board radiation doses received at IBERIA commercial flights are presented. The routes studied cover the most significant destinations and provide a good estimate of the route doses as required by the new Spanish regulations on air crew radiation protection. Details on the experimental procedures and calibration methods are given. The experimental measurements from the different instruments (Tissue Equivalent Proportional Counter and the combination of a high pressure ion chamber and a high-energy neutron compensated rem-counter) and their comparison with the predictions from some route-dose codes (CARI-6, EPCARD 3.2) are discussed. In contrast with the already published data, which are mainly focused on North latitudes over parallel 50, many of the data presented in this work have been obtained for routes from Spain to Central and South America.

  16. Frequency-tuned microwave photon counter based on a superconductive quantum interferometer

    NASA Astrophysics Data System (ADS)

    Shnyrkov, V. I.; Yangcao, Wu; Soroka, A. A.; Turutanov, O. G.; Lyakhno, V. Yu.

    2018-03-01

    Various types of single-photon counters operating in infrared, ultraviolet, and optical wavelength ranges are successfully used to study electromagnetic fields, analyze radiation sources, and solve problems in quantum informatics. However, their operating principles become ineffective at millimeter band, S-band, and ultra-high frequency bands of wavelengths due to the decrease in quantum energy by 4-5 orders of magnitude. Josephson circuits with discrete Hamiltonians and qubits are a good foundation for the construction of single-photon counters at these frequencies. This paper presents a frequency-tuned microwave photon counter based on a single-junction superconducting quantum interferometer and flux qutrit. The control pulse converts the interferometer into a two-level system for resonance absorption of photons. Decay of the photon-induced excited state changes the magnetic flux in the interferometer, which is measured by a SQUID magnetometer. Schemes for recording the magnetic flux using a DC SQUID or ideal parametric detector, based on a qutrit with high-frequency excitation, are discussed. It is shown that the counter consisting of an interferometer with a Josephson junction and a parametric detector demonstrates high performance and is capable of detecting single photons in a microwave band.

  17. A compact and high efficiency GAGG well counter for radiocesium concentration measurements

    NASA Astrophysics Data System (ADS)

    Yamamoto, Seiichi; Ogata, Yoshimune

    2014-07-01

    After the Fukushima nuclear disaster, social concern about radiocesium (137Cs and 134Cs) contamination in food increased. However, highly efficient instruments that can measure low level radioactivity are quite expensive and heavy. A compact, lightweight, and reliable radiation detector that can inexpensively monitor low level radiocesium is highly desired. We developed a compact and highly efficient radiocesium detector to detect ~32 keV X-rays from radiocesium instead of high energy gamma photons. A 1-mm thick GAGG scintillator was selected to effectively detect ~32 keV X-rays from 137Cs to reduce the influence of ambient radiation. Four sets of 25 mm×25 mm×1 mm GAGG plates, each of which was optically coupled to a triangular-shaped light guide, were optically coupled to a photomultiplier tube (PMT) to form a square-shaped well counter. Another GAGG plate was directly optically coupled to the PMT to form its bottom detector. The energy resolution of the GAGG well counter was 22.3% FWHM for 122 keV gamma rays and 32% FWHM for ~32 keV X-rays. The counting efficiency for the X-rays from radiocesium (mixture of 137Cs and 134Cs) was 4.5%. In measurements of the low level radiocesium mixture, a photo-peak of ~32 keV X-rays can clearly be distinguished from the background. The minimum detectable activity (MDA) was estimated to be ~100 Bq/kg for 1000 s measurement. The results show that our developed GAGG well counter is promising for the detection of radiocesium in food.

  18. Ground albedo neutrons produced by cosmic radiations

    NASA Astrophysics Data System (ADS)

    Kodama, M.

    1983-05-01

    Day-to-day variations of cosmic-ray-produced neutron fluxes near the earth's ground surface are measured by using three sets of paraffin-moderated BF3 counters, which are installed in different locations, 3 m above ground, ground level, and 20 cm under ground. Neutron flux decreases observed by these counters when snowcover exists show that there are upward-moving neutrons, that is, ground albedo neutron near the ground surface. The amount of albedo neutrons is estimated to be about 40 percent of total neutron flux in the energy range 1-10 to the 6th eV.

  19. Hodoscope readout system

    DOEpatents

    Lee, L.Y.

    1973-12-01

    A readout system has been provided for reading out a radiation multidetector device with a reduced number of signal sensors. A radiation hodoscope, such as an array of scintillation counters, multiwire proportional counter array, or a set of multidetectors which do not receive signals simultaneously, is divided into equal numbered groups. A first group of signal terminals is connected to the equal numbered groups of detectors so that a signal from any one of the detectors of a group will be fed to one of the first group of terminals. A second group of signal terminals is connected to the detector groups so that a signal from a particular numbered detector of each of the detector groups is connected to one of the second group of terminals. Both groups of signal terminals are, in turn, coupled to signal sensors so that when a signal is simultaneously observed in one of the first group of terminals and one of the second group of tenniinals the specific detector detecting a radiation event is determined. The sensors are arranged in such a manner that a binary code is developed from their outputs which can be stored in a digital storage means according to the location of the event in the multidetector device. (Official Gazette)

  20. ASNC upgrade for nuclear material accountancy of ACPF

    NASA Astrophysics Data System (ADS)

    Seo, Hee; Ahn, Seong-Kyu; Lee, Chaehun; Oh, Jong-Myeong; Yoon, Seonkwang

    2018-02-01

    A safeguards neutron coincidence counter for nuclear material accountancy of the Advanced spent-fuel Conditioning Process Facility (ACPF), known as the ACP Safeguards Neutron Counter (ASNC), was upgraded to improve its remote-handling and maintenance capabilities. Based on the results of the previous design study, the neutron counter was completely rebuilt, and various detector parameters for neutron coincidence counting (i.e., high-voltage plateau, efficiency profile, dead time, die-away time, gate length, doubles gate fraction, and stability) were experimentally determined. The measurement data showed good agreement with the MCNP simulation results. To the best of the authors' knowledge, the ASNC is the only safeguards neutron coincidence counter in the world that is installed and operated in a hot-cell. The final goals to be achieved were (1) to evaluate the uncertainty level of the ASNC in nuclear material accountancy of the process materials of the oxide-reduction process for spent fuels and (2) to evaluate the applicability of the neutron coincidence counting technique within a strong radiation field (e.g., in a hot-cell environment).

  1. Controlling electron quantum paths for generation of circularly polarized high-order harmonics by H2+ subject to tailored (ω , 2 ω ) counter-rotating laser fields

    NASA Astrophysics Data System (ADS)

    Heslar, John; Telnov, Dmitry A.; Chu, Shih-I.

    2018-04-01

    Recently, studies of high-order harmonics (HHG) from atoms driven by bichromatic counter-rotating circularly polarized laser fields as a source of coherent circularly polarized extreme ultraviolet (XUV) and soft-x-ray beams in a tabletop-scale setup have received considerable attention. Here, we demonstrate the ability to control the electron recollisions giving three returns per one cycle of the fundamental frequency ω by using tailored bichromatic (ω , 2 ω ) counter-rotating circularly polarized laser fields with a molecular target. The full control of the electronic pathway is first analyzed by a classical trajectory analysis and then extended to a detailed quantum study of H2+ molecules in bichromatic (ω , 2 ω ) counter-rotating circularly polarized laser fields. The radiation spectrum contains doublets of left- and right-circularly polarized harmonics in the XUV ranges. We study in detail the below-, near-, and above-threshold harmonic regions and describe how excited-state resonances alter the ellipticity and phase of the generated harmonic peaks.

  2. Comprehensive Review of Ultraviolet Radiation and the Current Status on Sunscreens

    PubMed Central

    Moon, Summer; Armstrong, Frank

    2012-01-01

    In the past, manufacturers’ labeling of sunscreen varied greatly, confusing the consumers regarding efficacy and the appropriate photoprotection provided by their products. Therefore, in June 2011, the United States Food and Drug Administration issued new guidelines for sunscreen labeling. Sunscreen products are over-the-counter drugs; therefore, they are regulated by the United States Food and Drug Administration to determine safety, efficacy, and labeling. This article discusses ultraviolet radiation and the positive and negative effects of ultraviolet radiation, provides a review of sunscreens, and discusses the new United States Food and Drug Administration regulations for sunscreens. PMID:23050030

  3. POCKET $beta$ AND $gamma$ RADIOMETER (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markelov, V.V.; Lushikhin, A.M.; Nikoforov, V.I.

    A pocket BETA and gamma rate meter was designed by the Academy of Medical Sciences of U.S.S.R. for detecting gamma radiation of 0.25 to 2 Mev and for BETA particles of 0 to 50 and 0 to 500 particles/cm/sup 2/sec, with energies of 0.5 to 2 Mev. Measurements of BETA particles are made through the hack wall opening in the appuratus. The opening is closed durtng the recording of gamma radiation, which permits differentiation between the BETA and gamma radiation. The accuracy of the counter is within plus or minus 15%. (R.V.J.)

  4. Method for generating extreme ultraviolet with mather-type plasma accelerators for use in Extreme Ultraviolet Lithography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hassanein, Ahmed; Konkashbaev, Isak

    A device and method for generating extremely short-wave ultraviolet electromagnetic wave uses two intersecting plasma beams generated by two plasma accelerators. The intersection of the two plasma beams emits electromagnetic radiation and in particular radiation in the extreme ultraviolet wavelength. In the preferred orientation two axially aligned counter streaming plasmas collide to produce an intense source of electromagnetic radiation at the 13.5 nm wavelength. The Mather type plasma accelerators can utilize tin, or lithium covered electrodes. Tin, lithium or xenon can be used as the photon emitting gas source.

  5. Radiation-hard ceramic Resistive Plate Chambers for forward TOF and T0 systems

    NASA Astrophysics Data System (ADS)

    Akindinov, A.; Dreyer, J.; Fan, X.; Kämpfer, B.; Kiselev, S.; Kotte, R.; Garcia, A. Laso; Malkevich, D.; Naumann, L.; Nedosekin, A.; Plotnikov, V.; Stach, D.; Sultanov, R.; Voloshin, K.

    2017-02-01

    Resistive Plate Chambers with ceramic electrodes are the main candidates for a use in precise multi-channel timing systems operating in high-radiation conditions. We report the latest R&D results on these detectors aimed to meet the requirements of the forward T0 counter at the CBM experiment. RPC design, gas mixture, limits on the bulk resistivity of ceramic electrodes, efficiency, time resolution, counting rate capabilities and ageing test results are presented.

  6. Nano structural anodes for radiation detectors

    DOEpatents

    Cordaro, Joseph V.; Serkiz, Steven M.; McWhorter, Christopher S.; Sexton, Lindsay T.; Retterer, Scott T.

    2015-07-07

    Anodes for proportional radiation counters and a process of making the anodes is provided. The nano-sized anodes when present within an anode array provide: significantly higher detection efficiencies due to the inherently higher electric field, are amenable to miniaturization, have low power requirements, and exhibit a small electromagnetic field signal. The nano-sized anodes with the incorporation of neutron absorbing elements (e.g., .sup.10B) allow the use of neutron detectors that do not use .sup.3He.

  7. Radiation-induced hematopoietic myelosuppression and genotoxicity get significantly countered by active principles of Podophyllum hexandrum: A study in strain 'A' mice.

    PubMed

    Verma, Savita; Gupta, Manju Lata

    2015-01-01

    To investigate the protective role of a novel formulation, prepared by a combination of three active principles isolated from Podophyllum hexandrum (G-002M), against radiation- mediated hematopoietic suppression and cytogenetic aberrations in lethally irradiated mice. G-002M, a combination of podophyllotoxin, podophyllotoxin-β-D glucoside and rutin, was administered intramuscularly in mice (- 1 h) to radiation (9 Gy) exposure. The animals were autopsied at different time intervals for further studies. Loss of bone marrow progenitor cells, altered myeloid/erythroid ratio, serum erythropoietin and pancytopenia in irradiated mice was found significantly (p < 0.001) ameliorated in G-002M pre-administered mice within 30 d. Bcl-2 (B-cell lymphoma 2) and BAX (Bcl-2-associated X) protein expression was also positively (p < 0.001) countered in these mice. Chromosomal aberrations in 30 d were found remarkably (p < 0.001) reduced in marrow of G-002M pretreated mice. Accelerated antioxidants, reduced DNA damage, stimulated lymphocyte proliferation and minimal cellular atrophy in spleen were some of the other key features observed in G-002M administered mice. Reduction in hematopoietic aplasia and chromosomal aberrations, besides, early recovery in bone marrow and spleen of G-002M pretreated mice, could be attributed to its free radical scavenging, DNA protecting and apoptotic proteins modulating ability against radiation.

  8. An instrument employing electronic counters and an emulsion chamber for studying heavy cosmic ray interactions (JACEE-3)

    NASA Technical Reports Server (NTRS)

    Austin, R. W.; Meegan, C. A.; Parnell, T. A.; Selig, W. J.; Watts, J. W.; Burnett, T. H.; Iwai, J.; Lord, J. J.; Strauscz, S.; Wilkes, R. J.; hide

    1983-01-01

    A JACEE-3 instrument was flown on a balloon in June 1982 for 6.1 sq m sr hr exposure at an average atmospheric depth of 5 gm/sq cm in order to study the cosmic ray spectra, composition, and interactions above 1 TeV. The nucleus-nucleus interactions were studied above 20 GeV/amu from z = 6 to z = 26. The electronic counters contained gas Cerenkov structures with a 1.0-cm thick lead glass and a 1.27-cm thick Teflon radiator. A comparison to the instrument prototype is made. Based on the electronic counter event data, the finding efficiency of the hodoscope is noted to be near 100 percent for z greater than or equal to 22. A comparison is made between the hodoscope-predicted position and track found at P3 in an emulsion chamber.

  9. TEPC measurements obtained on the Mir space station.

    PubMed

    Bottollier-Depois, J F; Siegrist, M; Petrov, V M; Shurshakov, V V; Bengin, V; Koslova, S B

    2002-10-01

    Measurements of the radiation environment inside the Mir space station were performed with a tissue equivalent proportional counter (TEPC) during the Antares mission in 1992, and over a long period following it. Interesting results concerning radiation measurements show (a) the South Atlantic Anomaly crossing, (b) the increase of radiation near the poles, and (c) the effects of solar particle events (the most important one occurring in early November 1992). This data also provides information about the dose and the quality factor of the radiation to which the cosmonauts were exposed during different missions. These data are compared with measurements obtained using a solid state detector. c2002 Elsevier Science Ltd. All rights reserved.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farina, R.; Brandao-Mello, C.E.; Oliveira, A.R.

    In September 1987, the Goiania radiological accident involving a source of {sup 137}Cs culminated in about 140 victims who presented internal and/or external contamination and/or external exposure to radiation and/or radiation burns. Internal contamination was verified through analysis of urine and fecal samples. Internal contamination was also evaluated by measurements performed at the whole-body counter installed in Goiania in November 1987. To enhance the decorporation of 137Cs, patients were treated with the following: (1) Prussian Blue, oral administration, in 46 patients; (2) diuretics, oral administration, in 17 patients; (3) induced perspiration, increasing {sup 137}Cs elimination. These procedures were done undermore » rigorous clinical evaluation and considering the data from assay of excreta and data obtained from the whole-body counter. The doses of Prussian Blue exceeded about 6.5 times the dose previously indicated in the literature. It was the first time diuretics were used in humans to treat {sup 137}Cs internal contamination. The results of these procedures are discussed.« less

  11. Performance and field tests of a handheld Compton camera using 3-D position-sensitive scintillators coupled to multi-pixel photon counter arrays

    NASA Astrophysics Data System (ADS)

    Kishimoto, A.; Kataoka, J.; Nishiyama, T.; Fujita, T.; Takeuchi, K.; Okochi, H.; Ogata, H.; Kuroshima, H.; Ohsuka, S.; Nakamura, S.; Hirayanagi, M.; Adachi, S.; Uchiyama, T.; Suzuki, H.

    2014-11-01

    After the nuclear disaster in Fukushima, radiation decontamination has become particularly urgent. To help identify radiation hotspots and ensure effective decontamination operation, we have developed a novel Compton camera based on Ce-doped Gd3Al2Ga3O12 scintillators and multi-pixel photon counter (MPPC) arrays. Even though its sensitivity is several times better than that of other cameras being tested in Fukushima, we introduce a depth-of-interaction (DOI) method to further improve the angular resolution. For gamma rays, the DOI information, in addition to 2-D position, is obtained by measuring the pulse-height ratio of the MPPC arrays coupled to ends of the scintillator. We present the detailed performance and results of various field tests conducted in Fukushima with the prototype 2-D and DOI Compton cameras. Moreover, we demonstrate stereo measurement of gamma rays that enables measurement of not only direction but also approximate distance to radioactive hotspots.

  12. Real-time {sup 90}Sr Counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaneko, Naomi; Kawai, Hideyuki; Kodama, Satoshi

    2015-07-01

    Radioisotopes have been emitted around Japan due to a nuclear accident at the Fukushima Daiichi nuclear power station in March 2011. A problem is the contaminated water including the atomic nucleus which relatively has a long half- life time and soluble such as {sup 90}Sr, {sup 137}Cs. Internal exposures by {sup 90}Sr are more dangerous than {sup 137}Cs's because Sr has effective half-life time of 18 years and property of accumulation in a born. We have developed real-time {sup 90}Sr counter which is sensitive beta-ray of maximum kinematic energy of 2.28 MeV from {sup 90}Sr and insensitive of beta-ray ofmore » maximum kinematic energy of 1.17 MeV and gamma-ray from {sup 90}Sr by Cherenkov detection. This counter composes of Cerenkov counter, trigger scintillation counter and veto counter. Silica aerogel for Cherenkov counter can obtain refractive index between 1.017 and 1.049 easily. And wavelength shifting fiber (WLSF) is used as a light guide for extending effective area and producing lower cost. A mechanism of the identification of {sup 90}Sr is explained in following. In case of {sup 90}Sr, when the trigger counter reacts on the beta-ray from {sup 90}Sr, aerogel emits the Cherenkov light and WLSF reacts and read the Cherenkov light. On the other hand, in case of {sup 137}Cs, the trigger counter reacts on the beta-ray, aerogel stops the beta- ray and Cherenkov light is not emitted. Therefore, aerogel has a function as a radiator and shielding material. the gamma-ray is not reacted on the lower density detector. Cosmic rays would be also reacted by the veto counter. A prototype counter whose the effective area is 30 cm x 10 cm was obtained (2.0±1.2){sup 3} of mis-identification as {sup 137}Cs/{sup 90}Sr. Detection limit in the surface contamination inspection depends on measurement time and effective area mainly. The sensitivity of wide range, 10{sup -2} - 10{sup 4} Bq/cm{sup 2}, is obtained by adjustment of detection level in circuit of this counter. A lower radioactive sample (< 10{sup -2} Bq/cm{sup 2}) allows be detected significantly by heating treatment to evaporate water shielding the beta-rays. (authors)« less

  13. Prototype of IGZO-TFT preamplifier and analog counter for pixel detector

    NASA Astrophysics Data System (ADS)

    Shimazoe, K.; Koyama, A.; Takahashi, H.; Shindoh, T.; Miyoshi, H.

    2017-02-01

    IGZO-TFT (Indium Galium Zinc Oxide-Thin Film Transistor) is a promising technology for controlling large display areas and large area sensors because of its very low leakage current in the off state and relatively low cost. IGZO has been used as a switching gate for a large area flat-panel detector. The photon counting capability for X-ray medical imaging has been investigated and expected for low-dose exposure and material determination. Here the design and fabrication of a charge sensitive preamplifier and analog counter using IGZO-TFT processes and its performance are reported for the first time to be used for radiation photon counting applications.

  14. CALCIUM ABSORPTION IN MAN: BASED ON LARGE VOLUME LIQUID SCINTILLATION COUNTER STUDIES.

    PubMed

    LUTWAK, L; SHAPIRO, J R

    1964-05-29

    A technique has been developed for the in vivo measurement of absorption of calcium in man after oral administration of 1 to 5 microcuries of calcium-47 and continuous counting of the radiation in the subject's arm with a large volume liquid scintillation counter. The maximum value for the arm counting technique is proportional to the absorption of tracer as measured by direct stool analysis. The rate of uptake by the arm is lower in subjects with either the malabsorption syndrome or hypoparathyroidism. The administration of vitamin D increases both the absorption rate and the maximum amount of calcium absorbed.

  15. Recent Re-Measurement of Neutron and Gamma-Ray Spectra 1080 Meters from the APRD (Army Pulse Radiation Division) Critical Facility,

    DTIC Science & Technology

    1984-01-01

    TISSUE-EQUIVALENT ION CHAMBER GM - GEIGER-MUELLER COUNTER TE-GM - DIFFERENCE BETWEEN TE AND GM DATA MICRODOSE - MICRODOSIMETRY USING 0.5" ROSSI COUNTER...KERMA 4.26+8 1979 APRO NE-213+PR NEUTRON KERMA 4.26+8 1979 WWD NE-213 NEUTRON KERMA 3.10+8 > 550 KEV 1980 DREO MICRODOSE NEUTRON KERMA 4.32+8 1979...APRD GM GAMMA KERMA 3.86+7 1979 WWD NE-213 GAMMA KERMA 4.34+7 > 450 KEV 1980 DREO MICRODOSE GAMMA KERMA 3.90+7 76 1979 APRD TE TOTAL KERMA 4.50+8 50 c.c

  16. Study of microdosimetric energy deposition patterns in tissue-equivalent medium due to low-energy neutron fields using a graphite-walled proportional counter.

    PubMed

    Waker, A J; Aslam

    2011-06-01

    To improve radiation protection dosimetry for low-energy neutron fields encountered in nuclear power reactor environments, there is increasing interest in modeling neutron energy deposition in metrological instruments such as tissue-equivalent proportional counters (TEPCs). Along with these computational developments, there is also a need for experimental data with which to benchmark and test the results obtained from the modeling methods developed. The experimental work described in this paper is a study of the energy deposition in tissue-equivalent (TE) medium using an in-house built graphite-walled proportional counter (GPC) filled with TE gas. The GPC is a simple model of a standard TEPC because the response of the counter at these energies is almost entirely due to the neutron interactions in the sensitive volume of the counter. Energy deposition in tissue spheres of diameter 1, 2, 4 and 8 µm was measured in low-energy neutron fields below 500 keV. We have observed a continuously increasing trend in microdosimetric averages with an increase in neutron energy. The values of these averages decrease as we increase the simulated diameter at a given neutron energy. A similar trend for these microdosimetric averages has been observed for standard TEPCs and the Rossi-type, TE, spherical wall-less counter filled with propane-based TE gas in the same energy range. This implies that at the microdosimetric level, in the neutron energy range we employed in this study, the pattern of average energy deposited by starter and insider proton recoil events in the gas is similar to those generated cumulatively by crosser and stopper events originating from the counter wall plus starter and insider recoil events originating in the sensitive volume of a TEPC.

  17. Study design: Evaluating gene–environment interactions in the etiology of breast cancer – the WECARE study

    PubMed Central

    Bernstein, Jonine L; Langholz, Bryan; Haile, Robert W; Bernstein, Leslie; Thomas, Duncan C; Stovall, Marilyn; Malone, Kathleen E; Lynch, Charles F; Olsen, Jørgen H; Anton-Culver, Hoda; Shore, Roy E; Boice, John D; Berkowitz, Gertrud S; Gatti, Richard A; Teitelbaum, Susan L; Smith, Susan A; Rosenstein, Barry S; Børresen-Dale, Anne-Lise; Concannon, Patrick; Thompson, W Douglas

    2004-01-01

    Introduction Deficiencies in cellular responses to DNA damage can predispose to cancer. Ionizing radiation can cause cluster damage and double-strand breaks (DSBs) that pose problems for cellular repair processes. Three genes (ATM, BRCA1, and BRCA2) encode products that are essential for the normal cellular response to DSBs, but predispose to breast cancer when mutated. Design To examine the joint roles of radiation exposure and genetic susceptibility in the etiology of breast cancer, we designed a case-control study nested within five population-based cancer registries. We hypothesized that a woman carrying a mutant allele in one of these genes is more susceptible to radiation-induced breast cancer than is a non-carrier. In our study, 700 women with asynchronous bilateral breast cancer were individually matched to 1400 controls with unilateral breast cancer on date and age at diagnosis of the first breast cancer, race, and registry region, and counter-matched on radiation therapy. Each triplet comprised two women who received radiation therapy and one woman who did not. Radiation absorbed dose to the contralateral breast after initial treatment was estimated with a comprehensive dose reconstruction approach that included experimental measurements in anthropomorphic and water phantoms applying patient treatment parameters. Blood samples were collected from all participants for genetic analyses. Conclusions Our study design improves the potential for detecting gene–environment interactions for diseases when both gene mutations and the environmental exposures of interest are rare in the general population. This is particularly applicable to the study of bilateral breast cancer because both radiation dose and genetic susceptibility have important etiologic roles, possibly by interactive mechanisms. By using counter-matching, we optimized the informativeness of the collected dosimetry data by increasing the variability of radiation dose within the case–control sets and enhanced our ability to detect radiation–genotype interactions. PMID:15084244

  18. 47 CFR 2.1515 - Spectral measurements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... applicable, change the type of modulation of the EPIRB and record the shift in carrier frequency as observed... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL FREQUENCY ALLOCATIONS AND RADIO TREATY MATTERS; GENERAL... radiated signal from the EPIRB. A signal generator and frequency counter capable of operating at 121.5 and...

  19. Longitudinal monitoring of whole body counter NaI(TI) detector efficiency

    USDA-ARS?s Scientific Manuscript database

    Assessing accuracy of radiation counting systems over time is critical. We examined long-term WBC performance in detail. Efficiency factors for 54 detectors were updated annually over several years. Newer efficiency values were compared with baseline and with annual values. Overall system efficiency...

  20. Electro-Optical Sensing Apparatus and Method for Characterizing Free-Space Electromagnetic Radiation

    DOEpatents

    Zhang, Xi-Cheng; Libelo, Louis Francis; Wu, Qi

    1999-09-14

    Apparatus and methods for characterizing free-space electromagnetic energy, and in particular, apparatus/method suitable for real-time two-dimensional far-infrared imaging applications are presented. The sensing technique is based on a non-linear coupling between a low-frequency electric field and a laser beam in an electro-optic crystal. In addition to a practical counter-propagating sensing technique, a co-linear approach is described which provides longer radiated field--optical beam interaction length, thereby making imaging applications practical.

  1. DISPOSITION OF THE INNER RADIATION BELT AND MAGNETIC FIELD OF THE EARTH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    GORCHAKOV, IE. V.

    1963-02-01

    A scintillation counter on Sputnik III was used to conduct ionization measurement in a sodium iodide crystal and register the number of events releasing more than 35 kev in the crystal. The boundary of the inner radiation belt shows a strong longitudinal effect. The observed dependence on longitude of the boundary was explained by the fact that the inner belt consists of particles captured by the geomagnetic field and constitutes a noncentral dipole field. (C.E.S.)

  2. Computerized tomography platform using beta rays

    NASA Astrophysics Data System (ADS)

    Paetkau, Owen; Parsons, Zachary; Paetkau, Mark

    2017-12-01

    A computerized tomography (CT) system using a 0.1 μCi Sr-90 beta source, Geiger counter, and low density foam samples was developed. A simple algorithm was used to construct images from the data collected with the beta CT scanner. The beta CT system is analogous to X-ray CT as both types of radiation are sensitive to density variations. This system offers a platform for learning opportunities in an undergraduate laboratory, covering topics such as image reconstruction algorithms, radiation exposure, and the energy dependence of absorption.

  3. COSMIC RAYS AND COSMIC SPACE (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vernova, S.N.

    1960-08-01

    An account is given of recent studies of cosmic rays utilizing both earthbound stations and artificial earth satellites. Phenomena recently uncovered by sputniks are described. A description is given of the cosmic ray laboratory of Moscow University. A particle possessing an energy of l0/sup 15/ ev was detected and the equipment and procedure by which this was done are described. mu mesons in a particle shower produced by cosmic rays were detected at a depth of thirty meters underground. The apparatus required in the sputriks for the study of cosmic rays outside the earth's atmosphere is discussed. The equipment inmore » the sputniks launched to date was transistorized; scintillation counters were used to determine particle energies. A description is given of the large burst of radiation detected by the second sputnik on Nov. 7, 1957. This burst was observed only at latitudes of about 50 to 70 degrees north latitude. The third sputnik had a scintillation counter of high sensitivity which detected relatively weak fluxes of electrons. This equipment fixed the location of the high intensity radiation belt around the earth. A typical graph of count rate and energy current versus geographic location is given. Data are given that indicate the coincidence of peak radiation intensities with those regions where the aurora borealis is seen. The radiation belt extends up to approximately 60,000 km from the earth's surface and is bounded by the magnetic lines of force that intersect the earth' s surface at geomagnetic latitudes of 55 deg and 70 deg . The earth's magnetic field traps these particles and holds them in an orbit that follows magnetic lines of force and oscillates from the northern to the southern hemisphere for long periods of time. A diagram is given of the trajectory of the first Soviet cosmic rocket and changes in radiation intensity along this trajectory are indicated. A maximum radiation intensity was detected at a distance of 20,000 km from the earth's surface. A diagram compares the data of the first and second Soviet cosmic rockets. It is indicated that radiation intensity in the outer belt varies with time due to variation of emanations from the sun. The energy spectrum of radiation in the outer belt was obtained with gas discharge and scintillation counters installed behind varying amounts of lead, copper, and aluminum shielding. Results are given in a diagram of particle and energy flux versus distance from the earth. The conclusion is reached that the outer radiation belt consists of electrons whose energies vary over six orders of magnitude. However the data from the second rocket indicated that the upper limit of electron energies appears to be 5 Mev. The electron flux is highest at an energy of about 1 Mev. It is pointed out that in the outer radiation belt the energy density of radiation approaches its maximum possible value, that is, the energy density of the earth's magnetic field at that distance. A discussion is given of the inner radiation belt, first described by Van Allen. No evidence of radiation belts about the moon was found. A discussion of the possible origins of the outer radiation belt of the earth and of other radiation belts and magnetic fields in space is given. In the study of solar flares, 1500 radiosonde balloon flights were made during the IGY. These flights established that solar flares are an extreme hazard for space travelers. (TTT)« less

  4. Comparison of Integrated Radiation Transport Models with TEPC Measurements for the Average Quality Factors in Spaceflights

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Nikjoo, Hooshang; Dicello, John F.; Pisacane, Vincent; Cucinotta, Francis A.

    2007-01-01

    The purpose of this work is to test our theoretical model for the interpretation of radiation data measured in space. During the space missions astronauts are exposed to the complex field of radiation type and kinetic energies from galactic cosmic rays (GCR), trapped protons, and sometimes solar particle events (SPEs). The tissue equivalent proportional counter (TEPC) is a simple time-dependent approach for radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to Microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Q(sub ave)(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Q(sub ave)(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y, deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. Monte Carlo track structure simulation was employed to obtain the response of a TEPC irradiated with charged particle for an equivalent site diameter of 1 micron of wall-less counter. The calculated data of the energy absorption in the wall-less counter were compiled for various y values for several ion types at various discrete projectile energy levels. For the simulation of TEPC response from the mixed radiation environments inside a spacecraft, such as, Space Shuttle and International Space Station, the complete microdosimetric TEPC response, f( y, E, Z), were calculated with the Monte Carlo theoretical results by using the first order Lagrangian interpolation for a monovariate function at a given y value (y = 0.1 keV/micron 5000 keV/micron) at any projectile energy level (E = 0.01 MeV/u to 50,000 MeV/u) of each specific radiation type (Z = 1 to 28). Because the anomalous response has been observed at large event sizes in the experiment due to the escape of energy out of sensitive volume by delta-rays and the entry of delta-rays from the high-density wall into the low-density gas-volume cavity, Monte Carlo simulation was also made for the response of a walled-TEPC with wall thickness 2 mm and density 1 g/cm(exp 3). The radius of cavity was set to 6.35 mm and a gas density 7.874 x 10(exp -5) g/cm(exp 3). The response of the walled- and the wall-less counters were compared. The average quality factor Q(sub ave)(y) for trapped protons on STS-89 demonstrated the good agreement between the model calculations and flight TEPC data as shown. Using an integrated space radiation model (this includes the transport codes HZETRN and BRYNTRN, the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions of walled-TEPC from Monte-Carlo track simulations, we compared model calculations with walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. The Q(sub ave)(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Q(sub ave)(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Q(sub ave)(y). The GCR values are decreasing with the shield thickness. Our analysis for a proper interpretation of data supports the use of TEPCs for monitoring space radiation environment.

  5. Defense Threat Reduction Agency > Success Stories

    Science.gov Websites

    History Documents US Underground Nuclear Test History Reports NTPR Radiation Exposure Reports Enewetak Atoll Cleanup Documents TRAC About Who We Are Our Values History Locations Our Leadership Director counter WMD weapons systems, we have a long history of overcoming what others believe impossible

  6. 412th Brookhaven Lecture

    ScienceCinema

    Peter Vanier

    2017-12-09

    With new radiation detectors, finding smuggled nuclear materials in a huge container among thousands of others in a busy port becomes possible. To learn about these new detectors from a specialist who has spent several years developing these technologies, watch the 412th Brookhaven Lecture, "Advanced Neutron Detection Methods: New Tools for Countering Nuclear Terrorism."

  7. Experimental study of the influence of the counter and scintillator on the universal curves in the cross-efficiency method in LSC.

    PubMed

    Cassette, P; Tartès, I

    2014-05-01

    The cross-efficiency method in LSC is one of the approaches proposed for the extension of the Système International de Référence (SIR) to radionuclides emitting no gamma radiation. This method is based on a so-called "universal cross-efficiency curve", establishing a relationship between the detection efficiency of the radionuclide to be measured and the detection efficiency of a suitable tracer. This paper reports a study at LNHB on the influence of the scintillator and of the LS counter on the cross-efficiency curves. This was done by measuring the cross-efficiency curves obtained for (63)Ni and (55)Fe vs. (3)H, using three different commercial LS counters (Guardian 1414, Tricarb 3170 and Quantulus 1220), three different liquid scintillator cocktails (Ultima Gold, Hionic Fluor and PicoFluor 15 from Perkin Elmer(®)), and for chemical and colour-quenched sources. This study shows that these cross-efficiency curves are dependent on the scintillator, on the counter used and on the nature of the quenching phenomenon, and thus cannot definitively be considered as "universal". © 2013 Published by Elsevier Ltd.

  8. Localization of activities in the human body with a whole-body counter.

    PubMed

    Fischer, H; Schlagbauer, M

    2007-01-01

    The whole-body counter of the Radiation Protection Unit at the ARC Seibersdorf research GmbH has two HP Ge-detectors for measuring radionuclides, which are internally deposited in the human body. The detector system has a scanning geometry, where one detector is placed below the bed and the other detector above the bed. The body counter is placed in a massive shielded chamber. This device is especially used for measuring radioactive exposed workers with the possibility of intake by inhalation and ingestion. In the most cases whole-body counters are calibrated with anthropomorphic phantoms where activity is homogenously distributed. However, in some cases radioactivity can be located as a 'Hot Spot' in an organ. The localisation of 'Hot spots' at least in one dimension was the topic of this work. Experiments were done by means of a water-filled bottle phantom where three point sources (137Cs, 133Ba and 60Co) were placed at different positions. Measurements show that these radionuclides can be located within 1.5 cm along the longitudinal axis of the phantom with activities for 137Cs of at least 240 Bq, 133Ba of at least 670 Bq and 60Co of at least 140 Bq.

  9. Radioprotective property of an aqueous extract from valeriana wallichii.

    PubMed

    Katoch, Omika; Kaushik, Shikha; Kumar, Mysore Sadashiv Yogendra; Agrawala, Paban K; Misra, Kshipra

    2012-10-01

    Preparations of herbal drugs have drawn considerable interest in scientific community in recent years for the treatment of several stress related health problems including radiation-injury. An aqueous extract from Valeriana wallichii containing hesperidin as one of its major constituent was evaluated for its ability to protect against radiation-injury in model systems like plasmid deoxyribonucleic acid (DNA) and cultured human fibroblast cells. The extract was found to significantly counter radiation-induced free radicals at 4 h after 5 Gy irradiation, reduced prolonged oxidative stress led increase in mitochondrial mass, enhanced reproductive viability of cultured cells and protected against radiation-induced DNA damage in solution. Further studies are required to validate the radioprotective ability of the extract and to develop a safer radioprotective agent.

  10. Intraluminal radiation for esophageal cancer: a Howard University technique.

    PubMed

    Moorthy, C R; Nibhanupudy, J R; Ashayeri, E; Goldson, A L; Espinoza, M C; Nidiry, J J; Warner, O G; Roux, V J

    1982-03-01

    The objective of radiotherapeutic management in esophageal cancer is to accomplish maximum tumor sterilization with minimal normal tissue damage. This sincere effort is most often countered by the differential in tumor dose response vs normal tissue tolerance. Intraluminal isotope radiation, with its inherent advantage of rapid dose falloff, spares the lungs, the spinal cord, and other vital structures, yet yields adequately high doses to esophageal tumor. Though in existence since the turn of the century, the method of intracavitary radium bougie application dropped out of favor due to technical difficulties imposed by the size of the radium source and radiation exposure to the personnel involved. The authors describe a simple "iridium 192 afterloading intraluminal technique" that eliminates technical problems and reduces radiation exposure considerably.

  11. Voxel2MCNP: a framework for modeling, simulation and evaluation of radiation transport scenarios for Monte Carlo codes.

    PubMed

    Pölz, Stefan; Laubersheimer, Sven; Eberhardt, Jakob S; Harrendorf, Marco A; Keck, Thomas; Benzler, Andreas; Breustedt, Bastian

    2013-08-21

    The basic idea of Voxel2MCNP is to provide a framework supporting users in modeling radiation transport scenarios using voxel phantoms and other geometric models, generating corresponding input for the Monte Carlo code MCNPX, and evaluating simulation output. Applications at Karlsruhe Institute of Technology are primarily whole and partial body counter calibration and calculation of dose conversion coefficients. A new generic data model describing data related to radiation transport, including phantom and detector geometries and their properties, sources, tallies and materials, has been developed. It is modular and generally independent of the targeted Monte Carlo code. The data model has been implemented as an XML-based file format to facilitate data exchange, and integrated with Voxel2MCNP to provide a common interface for modeling, visualization, and evaluation of data. Also, extensions to allow compatibility with several file formats, such as ENSDF for nuclear structure properties and radioactive decay data, SimpleGeo for solid geometry modeling, ImageJ for voxel lattices, and MCNPX's MCTAL for simulation results have been added. The framework is presented and discussed in this paper and example workflows for body counter calibration and calculation of dose conversion coefficients is given to illustrate its application.

  12. Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions.

    PubMed

    Straume, T; Braby, L A; Borak, T B; Lusby, T; Warner, D W; Perez-Nunez, D

    2015-10-01

    Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable to the biological effectiveness of space radiation. Tissue-equivalent proportional counters (TEPCs) are such instruments. Unfortunately, present TEPCs are too large and power intensive to be used beyond low Earth orbit (LEO). Here, the authors describe a prototype of a compact TEPC designed for deep space applications with the capability to detect both ambient galactic cosmic rays and intense solar particle event radiation. The device employs an approach that permits real-time determination of yD (and thus quality factor) using a single detector. This was accomplished by assigning sequential sampling intervals as detectors “1” and “2” and requiring the intervals to be brief compared to the change in dose rate. Tests with g rays show that the prototype instrument maintains linear response over the wide dose-rate range expected in space with an accuracy of better than 5% for dose rates above 3 mGy h(-1). Measurements of yD for 200 MeV n(-1) carbon ions were better than 10%. Limited tests with fission spectrum neutrons show absorbed dose-rate accuracy better than 15%.

  13. Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions

    PubMed Central

    Straume, T.; Braby, L.A.; Borak, T.B.; Lusby, T.; Warner, D.W.; Perez-Nunez, D.

    2015-01-01

    Abstract Effects on human health from the complex radiation environment in deep space have not been measured and can only be simulated here on Earth using experimental systems and beams of radiations produced by accelerators, usually one beam at a time. This makes it particularly important to develop instruments that can be used on deep-space missions to measure quantities that are known to be relatable to the biological effectiveness of space radiation. Tissue-equivalent proportional counters (TEPCs) are such instruments. Unfortunately, present TEPCs are too large and power intensive to be used beyond low Earth orbit (LEO). Here, the authors describe a prototype of a compact TEPC designed for deep space applications with the capability to detect both ambient galactic cosmic rays and intense solar particle event radiation. The device employs an approach that permits real-time determination of (and thus quality factor) using a single detector. This was accomplished by assigning sequential sampling intervals as detectors “1” and “2” and requiring the intervals to be brief compared to the change in dose rate. Tests with γ rays show that the prototype instrument maintains linear response over the wide dose-rate range expected in space with an accuracy of better than 5% for dose rates above 3 mGy h−1. Measurements of for 200 MeV n−1 carbon ions were better than 10%. Limited tests with fission spectrum neutrons show absorbed dose-rate accuracy better than 15%. PMID:26313585

  14. Strategies for Discovery of Small Molecule Radiation Protectors and Radiation Mitigators

    PubMed Central

    Greenberger, Joel S.; Clump, David; Kagan, Valerian; Bayir, Hülya; Lazo, John S.; Wipf, Peter; Li, Song; Gao, Xiang; Epperly, Michael W.

    2011-01-01

    Mitochondrial targeted radiation damage protectors (delivered prior to irradiation) and mitigators (delivered after irradiation, but before the appearance of symptoms associated with radiation syndrome) have been a recent focus in drug discovery for (1) normal tissue radiation protection during fractionated radiotherapy, and (2) radiation terrorism counter measures. Several categories of such molecules have been discovered: nitroxide-linked hybrid molecules, including GS-nitroxide, GS-nitric oxide synthase inhibitors, p53/mdm2/mdm4 inhibitors, and pharmaceutical agents including inhibitors of the phosphoinositide-3-kinase pathway and the anti-seizure medicine, carbamazepine. Evaluation of potential new radiation dose modifying molecules to protect normal tissue includes: clonogenic radiation survival curves, assays for apoptosis and DNA repair, and irradiation-induced depletion of antioxidant stores. Studies of organ specific radioprotection and in total body irradiation-induced hematopoietic syndrome in the mouse model for protection/mitigation facilitate rational means by which to move candidate small molecule drugs along the drug discovery pipeline into clinical development. PMID:22655254

  15. Nuclear Science Symposium, 23rd, Scintillation and Semiconductor Counter Symposium, 15th, and Nuclear Power Systems Symposium, 8th, New Orleans, La., October 20-22, 1976, Proceedings

    NASA Technical Reports Server (NTRS)

    Wagner, L. J.

    1977-01-01

    The volume includes papers on semiconductor radiation detectors of various types, components of radiation detection and dosimetric systems, digital and microprocessor equipment in nuclear industry and science, and a wide variety of applications of nuclear radiation detectors. Semiconductor detectors of X-rays, gamma radiation, heavy ions, neutrons, and other nuclear particles, plastic scintillator arrays, drift chambers, spark wire chambers, and radiation dosimeter systems are reported on. Digital and analog conversion systems, digital data and control systems, microprocessors, and their uses in scientific research and nuclear power plants are discussed. Large-area imaging and biomedical nucleonic instrumentation, nuclear power plant safeguards, reactor instrumentation, nuclear power plant instrumentation, space instrumentation, and environmental instrumentation are dealt with. Individual items are announced in this issue.

  16. Three- and two-dimensional simulations of counter-propagating shear experiments at high energy densities at the National Ignition Facility

    DOE PAGES

    Wang, Ping; Zhou, Ye; MacLaren, Stephan A.; ...

    2015-11-06

    Three- and two-dimensional numerical studies have been carried out to simulate recent counter-propagating shear flow experiments on the National Ignition Facility. A multi-physics three-dimensional, time-dependent radiation hydrodynamics simulation code is used. Using a Reynolds Averaging Navier-Stokes model, we show that the evolution of the mixing layer width obtained from the simulations agrees well with that measured from the experiments. A sensitivity study is conducted to illustrate a 3D geometrical effect that could confuse the measurement at late times, if the energy drives from the two ends of the shock tube are asymmetric. Implications for future experiments are discussed.

  17. THz Hot-Electron Photon Counter

    NASA Technical Reports Server (NTRS)

    Karasik, Boris S.; Sergeev, Andrei V.

    2004-01-01

    We present a concept for the hot-electron transition-edge sensor capable of counting THz photons. The main need for such a sensor is a spectroscopy on future space telescopes where a background limited NEP approx. 10(exp -20) W/H(exp 1/2) is expected at around 1 THz. Under these conditions, the rate of photon arrival is very low and any currently imaginable detector with sufficient sensitivity will operate in the photon counting mode. The Hot-Electron Photon Counter based on a submicron-size Ti bridge has a very low heat capacity which provides a high enough energy resolution (approx.140 GHz) at 0.3 K. With the sensor time constant of a few microseconds, the dynamic range would be approx. 30 dB. The sensor couples to radiation via a planar antenna and is read by a SQUID amplifier or by a 1-bit RSFQ ADC. A compact array of the antenna-coupled counters can be fabricated on a silicon wafer without membranes.

  18. Instrument intercomparison in the high-energy mixed field at the CERN-EU reference field (CERF) facility.

    PubMed

    Caresana, Marco; Helmecke, Manuela; Kubancak, Jan; Manessi, Giacomo Paolo; Ott, Klaus; Scherpelz, Robert; Silari, Marco

    2014-10-01

    This paper discusses an intercomparison campaign performed in the mixed radiation field at the CERN-EU (CERF) reference field facility. Various instruments were employed: conventional and extended-range rem counters including a novel instrument called LUPIN, a bubble detector using an active counting system (ABC 1260) and two tissue-equivalent proportional counters (TEPCs). The results show that the extended range instruments agree well within their uncertainties and within 1σ with the H*(10) FLUKA value. The conventional rem counters are in good agreement within their uncertainties and underestimate H*(10) as measured by the extended range instruments and as predicted by FLUKA. The TEPCs slightly overestimate the FLUKA value but they are anyhow consistent with it when taking the comparatively large total uncertainties into account, and indicate that the non-neutron part of the stray field accounts for ∼30 % of the total H*(10). © The Author 2013. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Leaves of Hippophae rhamnoides prevent taste aversion in gamma-irradiated rats.

    PubMed

    Gupta, Vanita; Bala, Madhu; Prasad, Jagdish; Singh, Surinder; Gupta, Manish

    2011-12-01

    Hippophae rhamnoides (Sea buckthorn), a traditionally known plant for nutritional and therapeutic values, is under active investigation for radioprotective properties. This study investigated effects of aqueous leaf extract from H. rhamnoides on (60)Co-γ-radiation induced changes in behavior, oxidative stress and serotonin levels in jejunum and plasma of rats. Conditioned taste aversion (CTA) was chosen as the assay to record behavioral changes and was assessed in terms of saccharine preference ratio (SPR). Whole body (60)Co-γ-irradiation (2 Gy) induced significant nonrecoverable CTA (25.6 ± 3.6% SPR, t(6) = 3.499, p < .05) and loss in body weight (b.w.). One time treatment with leaf extract before irradiation, countered radiation induced CTA and loss in body weight. The 12 mg/kg b.w. concentration of leaf extract caused complete extinction of CTA [100.3 ± 6.4% SPR, t(6) = 5.879, p < .01] after day 3 and the effect was significantly higher than positive control, Ondansetrone (70.0 ± 8.9% SPR). Treatment with leaf extract before irradiation significantly countered radiation induced (1) decrease in antioxidant protection, (2) increase in levels of corticosterone (CS) in plasma, (3) increase in levels of serotonin in jejunum and plasma. Present investigation demonstrated that H. rhamnoides leaf extract prevented behavioral changes induced at clinical radiation doses. Hippophae leaves are nontoxic and are being consumed as tea and other beverages. CTA in rats is a considered parallel process to nausea and vomiting in human beings. These findings, put together, suggest that dietary supplements from Hippophae leaves could be developed for preventing behavioral changes in subjects exposed to radiation.

  20. Measurement and simulation of lineal energy distribution at the CERN high energy facility with a tissue equivalent proportional counter.

    PubMed

    Rollet, S; Autischer, M; Beck, P; Latocha, M

    2007-01-01

    The response of a tissue equivalent proportional counter (TEPC) in a mixed radiation field with a neutron energy distribution similar to the radiation field at commercial flight altitudes has been studied. The measurements have been done at the CERN-EU High-Energy Reference Field (CERF) facility where a well-characterised radiation field is available for intercomparison. The TEPC instrument used by the ARC Seibersdorf Research is filled with pure propane gas at low pressure and can be used to determine the lineal energy distribution of the energy deposition in a mass of gas equivalent to a 2 microm diameter volume of unit density tissue, of similar size to the nuclei of biological cells. The linearity of the detector response was checked both in term of dose and dose rate. The effect of dead-time has been corrected. The influence of the detector exposure location and orientation in the radiation field on the dose distribution was also studied as a function of the total dose. The microdosimetric distribution of the absorbed dose as a function of the lineal energy has been obtained and compared with the same distribution simulated with the FLUKA Monte Carlo transport code. The dose equivalent was calculated by folding this distribution with the quality factor as a function of linear energy transfer. The comparison between the measured and simulated distributions show that they are in good agreement. As a result of this study the detector is well characterised, thanks also to the numerical simulations the instrument response is well understood, and it's currently being used onboard the aircrafts to evaluate the dose to aircraft crew caused by cosmic radiation.

  1. Atomic Particle Detection, Understanding the Atom Series.

    ERIC Educational Resources Information Center

    Hellman, Hal

    This booklet is one of the booklets in the "Understanding the Atom Series" published by the U. S. Atomic Energy Commission for high school science teachers and their students. The instruments used to detect both particles and electromagnetic radiation that emerge from the nucleus are described. The counters reviewed include ionization chambers,…

  2. An Environmental Chemistry Experiment: The Determination of Radon Levels in Water.

    ERIC Educational Resources Information Center

    Welch, Lawrence E.; Mossman, Daniel M.

    1994-01-01

    Describes a radiation experiment developed to complement a new environmental chemistry laboratory curriculum. A scintillation counter is used to measure radon in water. The procedure relies on the fact that toluene will preferentially extract radon from water. Sample preparation is complete in less than 90 minutes. Because the level of…

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mattox, Tracy M.; Koo, Bonil; Garcia, Guillermo

    An electrochromic device includes a nanostructured transition metal oxide bronze layer that includes one or more transition metal oxide and one or more dopant, a solid state electrolyte, and a counter electrode. The nanostructured transition metal oxide bronze selectively modulates transmittance of near-infrared (NIR) spectrum and visible spectrum radiation as a function of an applied voltage to the device.

  4. Device for detection and identification of carbon- and nitrogen-containing materials

    DOEpatents

    Karev, Alexander Ivanovich; Raevsky, Valery Georgievich; Dzhilavyan, Leonid Zavenovich; Laptev, Valery Dmitrievich; Pakhomov, Nikolay Ivanovich; Shvedunov, Vasily Ivanovich; Rykalin, Vladimir Ivanovich; Brothers, Louis Joseph; Wilhide, Larry K

    2014-03-25

    A device for detection and identification of carbon- and nitrogen-containing materials is described. In particular, the device performs the detection and identification of carbon- and nitrogen-containing materials by photo-nuclear detection. The device may comprise a race-track microtron, a breaking target, and a water-filled Cherenkov radiation counter.

  5. Electro-optical and Magneto-optical Sensing Apparatus and Method for Characterizing Free-space Electromagnetic Radiation

    DOEpatents

    Zhang, Xi-Cheng; Riordan, Jenifer Ann; Sun, Feng-Guo

    2000-08-29

    Apparatus and methods for characterizing free-space electromagnetic energy, and in particular, apparatus/method suitable for real-time two-dimensional far-infrared imaging applications are presented. The sensing technique is based on a non-linear coupling between a low-frequency electric (or magnetic) field and a laser beam in an electro-optic (or magnetic-optic) crystal. In addition to a practical counter-propagating sensing technique, a co-linear approach is described which provides longer radiated field-optical beam interaction length, thereby making imaging applications practical.

  6. Use of CLYC spectrometer in counter-terrorism applications

    NASA Astrophysics Data System (ADS)

    Ing, H.; Smith, M. B.; Koslowsky, M. R.; Andrews, H. R.

    2015-05-01

    A new scintillator crystal, now known as CLYC (Cs2LiYCl6:Ce), has been under development for over 15 years (1). It was primarily of interest for radiation detection applications because of its good energy resolution for gamma rays (< 4% for 662 keV gamma rays) and its capability for detection of thermal neutrons. The pulse shapes of the signals from the two radiations are different, which allow them to be separated electronically, permitting simultaneous detection of gamma rays and neutrons. The crystal is now commercially available. Early investigations of the neutron response by the current authors (2) revealed that CLYC also responds to fast neutrons. In fact, the good energy resolution of the response under monoenergetic neutron irradiations showed that CLYC was an excellent high-energy neutron spectrometer. This discovery has great impact on the field of neutron spectroscopy, which has numerous, although often specialized, applications. This presentation focuses on applications in counter-terrorism scenarios where neutrons may be involved. The relative importance of the fast neutron response of CLYC, compared to the thermal and gamma-ray response, will be discussed for these scenarios.

  7. Design and R&D of RICH detectors for EIC experiments

    NASA Astrophysics Data System (ADS)

    Del Dotto, A.; Wong, C.-P.; Allison, L.; Awadi, M.; Azmoun, B.; Barbosa, F.; Brooks, W.; Cao, T.; Chiu, M.; Cisbani, E.; Contalbrigo, M.; Datta, A.; Demarteau, M.; Durham, J. M.; Dzhygadlo, R.; Fields, D.; Furletova, Y.; Gleason, C.; Grosse-Perdekamp, M.; Harris, J.; He, X.; van Hecke, H.; Horn, T.; Huang, J.; Hyde, C.; Ilieva, Y.; Kalicy, G.; Kimball, M.; Kistenev, E.; Kulinich, Y.; Liu, M.; Majka, R.; McKisson, J.; Mendez, R.; Nadel-Turonski, P.; Park, K.; Peters, K.; Rao, T.; Pisani, R.; Qiang, Y.; Rescia, S.; Rossi, P.; Sarsour, M.; Schwarz, C.; Schwiening, J.; da Silva, C. L.; Smirnov, N.; Stein, H.; Stevens, J.; Sukhanov, A.; Syed, S.; Tate, A.; Toh, J.; Towell, C.; Towell, R.; Tsang, T.; Wagner, R.; Wang, J.; Woody, C.; Xi, W.; Xie, J.; Zhao, Z. W.; Zihlmann, B.; Zorn, C.

    2017-12-01

    An Electron-Ion Collider (EIC) has been proposed to further explore the strong force and QCD, focusing on the structure and the interaction of gluon-dominated matter. A generic detector R&D program (EIC PID consortium) for the particle identification in EIC experiments was formed to explore technologically advanced solutions in this scope. In this context two Ring Imaging Cherenkov (RICH) counters have been proposed: a modular RICH detector which consists of an aerogel radiator, a Fresnel lens, a mirrored box, and pixelated photon sensor; a dual-radiator RICH, consisting of an aerogel radiator and C2F6 gas in a mirror-focused configuration. We present the simulations of the two detectors and their estimated performance.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Del Dotto, A.; Wong, C. -P.; Allison, L.

    An Electron-Ion Collider (EIC) has been proposed to further explore the strong force and QCD, focusing on the structure and the interaction of gluon-dominated matter. A generic detector R&D program (EIC PID consortium) for the particle identification in EIC experiments was formed to explore technologically advanced solutions in this scope. In this context two Ring Imaging Cherenkov (RICH) counters have been proposed: a modular RICH detector which consists of an aerogel radiator, a Fresnel lens, a mirrored box, and pixelated photon sensor; a dual-radiator RICH, consisting of an aerogel radiator and C 2F 6 gas in a mirror-focused configuration. Asmore » a result, we present the simulations of the two detectors and their estimated performance.« less

  9. Dosimetry measurements using Timepix in mixed radiation fields induced by heavy ions; comparison with standard dosimetry methods

    PubMed Central

    Ploc, Ondrej; Kubancak, Jan; Sihver, Lembit; Uchihori, Yukio; Jakubek, Jan; Ambrozova, Iva; Molokanov, Alexander; Pinsky, Lawrence

    2014-01-01

    Objective of our research was to explore capabilities of Timepix for its use as a single dosemeter and LET spectrometer in mixed radiation fields created by heavy ions. We exposed it to radiation field (i) at heavy ion beams at HIMAC, Chiba, Japan, (ii) in the CERN's high-energy reference field (CERF) facility at Geneva, France/Switzerland, (iii) in the exposure room of the proton therapy laboratory at JINR, Dubna, Russia, and (iv) onboard aircraft. We compared the absolute values of dosimetric quantities obtained with Timepix and with other dosemeters and spectrometers like tissue-equivalent proportional counter (TEPC) Hawk, silicon detector Liulin, and track-etched detectors (TEDs).

  10. Poster - 51: A tumor motion-compensating system with tracking and prediction – a proof-of-concept study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guo, Kaiming; Teo, Peng; Kawalec, Philip

    2016-08-15

    Purpose: This work reports on the development of a mechanical slider system for the counter-steering of tumor motion in adaptive Radiation Therapy (RT). The tumor motion was tracked using a weighted optical flow algorithm and its position is being predicted with a neural network (NN). Methods: The components of the proposed mechanical counter-steering system includes: (1) an actuator which provides the tumor motion, (2) the motion detection using an optical flow algorithm, (3) motion prediction using a neural network, (4) a control module and (5) a mechanical slider to counter-steer the anticipated motion of the tumor phantom. An asymmetrical cosinemore » function and five patient traces (P1–P5) were used to evaluate the tracking of a 3D printed lung tumor. In the proposed mechanical counter-steering system, both actuator (Zaber NA14D60) and slider (Zaber A-BLQ0070-E01) were programed to move independently with LabVIEW and their positions were recorded by 2 potentiometers (ETI LCP12S-25). The accuracy of this counter-steering system is given by the difference between the two potentiometers. Results: The inherent accuracy of the system, measured using the cosine function, is −0.15 ± 0.06 mm. While the errors when tracking and prediction were included, is (0.04 ± 0.71) mm. Conclusion: A prototype tumor motion counter-steering system with tracking and prediction was implemented. The inherent errors are small in comparison to the tracking and prediction errors, which in turn are small in comparison to the magnitude of tumor motion. The results show that this system is suited for evaluating RT tracking and prediction.« less

  11. MEASUREMENTS OF THE IONISING RADIATION LEVEL AT A NUCLEAR MEDICINE FACILITY PERFORMING PET/CT EXAMINATIONS.

    PubMed

    Tulik, P; Kowalska, M; Golnik, N; Budzynska, A; Dziuk, M

    2017-05-01

    This paper presents the results of radiation level measurements at workplaces in a nuclear medicine facility performing PET/CT examinations. This study meticulously determines the staff radiation exposure in a PET/CT facility by tracking the path of patient movement. The measurements of the instantaneous radiation exposure were performed using an electronic radiometer with a proportional counter that was equipped with the option of recording the results on line. The measurements allowed for visualisation of the staff's instantaneous exposure caused by a patient walking through the department after the administration of 18F-FDG. An estimation of low doses associated with each working step and the exposure during a routine day in the department was possible. The measurements were completed by determining the average radiation level using highly sensitive thermoluminescent detectors. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. Perspectives of advanced thermal management in solar thermochemical syngas production using a counter-flow solid-solid heat exchanger

    NASA Astrophysics Data System (ADS)

    Falter, Christoph; Sizmann, Andreas; Pitz-Paal, Robert

    2017-06-01

    A modular reactor model is presented for the description of solar thermochemical syngas production involving counter-flow heat exchangers that recuperate heat from the solid phase. The development of the model is described including heat diffusion within the reactive material as it travels through the heat exchanger, which was previously identified to be a possibly limiting factor in heat exchanger design. Heat transfer within the reactive medium is described by conduction and radiation, where the former is modeled with the three-resistor model and the latter with the Rosseland diffusion approximation. The applicability of the model is shown by the analysis of heat exchanger efficiency for different material thicknesses and porosities in a system with 8 chambers and oxidation and reduction temperatures of 1000 K and 1800 K, respectively. Heat exchanger efficiency is found to rise strongly for a reduction of material thickness, as the element mass is reduced and a larger part of the elements takes part in the heat exchange process. An increase of porosity enhances radiation heat exchange but deteriorates conduction. The overall heat exchange in the material is improved for high temperatures in the heat exchanger, as radiation dominates the energy transfer. The model is shown to be a valuable tool for the development and analysis of solar thermochemical reactor concepts involving heat exchange from the solid phase.

  13. The importance of scattering, surface potential, and vanguard counter-potential in terahertz emission from gallium arsenide

    NASA Astrophysics Data System (ADS)

    Cortie, D. L.; Lewis, R. A.

    2012-06-01

    It is well established that under excitation by short (<1 ps), above-band-gap optical pulses, semiconductor surfaces may emit terahertz-frequency electromagnetic radiation via photocarrier diffusion (the dominant mechanism in InAs) or photocarrier drift (dominant in GaAs). Our three-dimensional ensemble Monte Carlo simulations allow multiple physical parameters to vary over wide ranges and provide unique direct insight into the factors controlling terahertz emission. We find for GaAs (in contrast to InAs), scattering and the surface potential are key factors. We further delineate in GaAs (as in InAs) the role of a vanguard counter-potential. The effects of varying dielectric constant, band-gap, and effective mass are similar in both emitter types.

  14. Coaxial anode improves sensitivity of gas radiation counters

    NASA Technical Reports Server (NTRS)

    Kraushaar, W. L.

    1974-01-01

    Anode wire itself is enclosed by three segments. Two on ends are rejector segments, and middle one is primary charge-detecting segment. Anode wire is made from tungsten and is surrounded by enamel insulation. Enamel is covered by segments of vapor-deposited gold. At one point in center segment, gold layer makes direct contact with anode wire.

  15. a Study of the Bioluminescence of Larger Zooplankton and the Effects of Low-Level Light Changes on Their Behavior.

    NASA Astrophysics Data System (ADS)

    van Keuren, Jeffrey Robert

    A bio-optical study was undertaken to quantify the relationships which exist between counter-illuminating organisms and the downwelling spectral light field in which they exist. The basic hypothesis behind counter-illumination is that the animal emits light using ventrally-oriented photophores to disrupt or eliminate the shadowed area on ventral surfaces. An organism lacking photophores sharply silhouettes against the highly directional downwelling irradiance, whereas by distributing photophores over the ventral surface of the body and closely matching the spectral and intensity characteristics of the downwelling light, this silhouette is obscured. Analysis carried out on changes in vertical distribution patterns in response to low-level intensity changes in ambient surface light suggested that diel migrating organisms begin to shift vertically in the water column when surface scalar irradiance decreased below or increased above 1.0 times10^{-2} muEin m^{-2} sec^ {-1}. Maximum aggregations of organisms, as defined by MOCNESS net sampling or single-frequency acoustic backscatter, appeared to remain within definable in situ blue-green isolume ranges varying less than a factor of ten throughout each night. Comparisons made between organism counter-illumination capacity and modeled in situ downwelling irradiance levels suggested that euphausiids, decapods and myctophids use between 1-10 percent of their maximum counter-illumination capacity to match the ambient downwelling light conditions. Modeling also suggested that up to 40 percent of the maximum measured bioluminescence output is required to match ambient irradiance in the shallower surface zones where aggregations of copepods, potential food sources, were commonly found at night. An optical study to quantify the radiative transfer of bioluminescence from a point source revealed that non -isotropic point sources produce radiance patterns that cannot be simply explained by inverse square losses. Therefore simple inverse-square estimates of bioluminescent propagation loss rates from organisms in the ocean are an oversimplification of the radiative transfer processes that occur when these emissions occur. Additionally, in evaluating counter-illumination, the distance of the receptor, such as the eyes of a potential predator, is critical in determining the effectiveness of the organisms in matching the uniform light field of their surrounding environment and ultimately avoiding detection and predation.

  16. Design and R&D of RICH detectors for EIC experiments

    DOE PAGES

    Del Dotto, A.; Wong, C. -P.; Allison, L.; ...

    2017-03-18

    An Electron-Ion Collider (EIC) has been proposed to further explore the strong force and QCD, focusing on the structure and the interaction of gluon-dominated matter. A generic detector R&D program (EIC PID consortium) for the particle identification in EIC experiments was formed to explore technologically advanced solutions in this scope. In this context two Ring Imaging Cherenkov (RICH) counters have been proposed: a modular RICH detector which consists of an aerogel radiator, a Fresnel lens, a mirrored box, and pixelated photon sensor; a dual-radiator RICH, consisting of an aerogel radiator and C 2F 6 gas in a mirror-focused configuration. Asmore » a result, we present the simulations of the two detectors and their estimated performance.« less

  17. A Shallow Underground Laboratory for Low-Background Radiation Measurements and Materials Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aalseth, Craig E.; Bonicalzi, Ricco; Cantaloub, Michael G.

    Abstract: Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths worldwide houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This manuscript describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. Wemore » conclude by presenting measurement targets and future opportunities.« less

  18. Analysis of the photoneutron activation effects generated by 9 MeV X-ray in a container cargo inspection facility.

    PubMed

    Cho, Young Ho; Kang, Bo Sun

    2010-06-01

    The X-ray container cargo inspection facility is extensively implemented with the key objective to counter international terrorism and illicit smuggling of the contraband items via the ports. However, activation products are generated from photoneutron capture reactions in the high-energy X-ray container cargo inspection facility. The activation products release inherent delayed radiations which occupational workers are exposed to. In this study, the activation products are estimated using Monte Carlo method and radiation safety of the facility in terms of occupational dose is reviewed.

  19. Computer registration of radioactive indicator-dilution curves.

    PubMed

    Shepherd, A P; Perry, M A; Alexander, G M; Granger, D N; Riedel, G L; Kvietys, P R; Franke, C P

    1983-12-01

    A system is described for recording indicator-dilution curves produced by gamma radiation-emitting tracers. The system consists of a flow-through cuvette in a well counter, appropriate commercially available gamma radiation-detecting equipment, an Apple II computer, and a two-channel pulse-counting interface of our own design. With the counting interface and the software described here, an investigator can simultaneously record two indicator-dilution curves produced by gamma emitters. Instead of having to wait hours or days for results, the investigator can watch the data being recorded and display the results in graphic form almost immediately after each injection.

  20. Systems analysis of Mars solar electric propulsion vehicles

    NASA Technical Reports Server (NTRS)

    Hickman, J. M.; Curtis, H. B.; Kenny, B. H.; Sefcik, R. J.

    1990-01-01

    Mission performance, mass, initial power, and cost are determined for solar electric propulsion vehicles across a range of payload masses, reference powers, and mission trajectories. Thick radiation shielding is added to arrays using indium phosphide or III-V multijunction solar cells to reduce the damage incurred through the radiation belts. Special assessments of power management and distribution systems, atmospheric drag, and energy storage are made. It is determined that atmospheric drag is of no great concern and that the energy storage used in countering drag is unnecessary. A scheme to package the arrays, masts, and ion thrusters into a single fairing is presented.

  1. Nuclear Science Symposium, 19th, and Nuclear Power Systems Symposium, 4th, Miami, Fla., December 6-8, 1972, Proceedings.

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Major topics covered include radiation monitoring instrumentation, nuclear circuits and systems, biomedical applications of nuclear radiation in diagnosis and therapy, plasma research for fusion power, reactor control and instrumentation, nuclear power standards, and applications of digital computers in nuclear power plants. Systems and devices for space applications are described, including the Apollo alpha spectrometer, a position sensitive detection system for UV and X-ray photons, a 4500-volt electron multiplier bias supply for satellite use, spark chamber systems, proportional counters, and other devices. Individual items are announced in this issue.

  2. Radial dependence of lineal energy distribution of 290-MeV/u carbon and 500-MeV/u iron ion beams using a wall-less tissue-equivalent proportional counter.

    PubMed

    Tsuda, Shuichi; Sato, Tatsuhiko; Watanabe, Ritsuko; Takada, Masashi

    2015-01-01

    Using a wall-less tissue-equivalent proportional counter for a 0.72-μm site in tissue, we measured the radial dependence of the lineal energy distribution, yf(y), of 290-MeV/u carbon ions and 500-MeV/u iron ion beams. The measured yf(y) distributions and the dose-mean of y, [Formula: see text], were compared with calculations performed with the track structure simulation code TRACION and the microdosimetric function of the Particle and Heavy Ion Transport code System (PHITS). The values of the measured [Formula: see text] were consistent with calculated results within an error of 2%, but differences in the shape of yf(y) were observed for iron ion irradiation. This result indicates that further improvement of the calculation model for yf(y) distribution in PHITS is needed for the analytical function that describes energy deposition by delta rays, particularly for primary ions having linear energy transfer in excess of a few hundred keV μm(-1). © The Author 2014. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  3. The response of a spherical tissue-equivalent proportional counter to iron particles from 200-1000 MeV/nucleon

    NASA Technical Reports Server (NTRS)

    Gersey, B. B.; Borak, T. B.; Guetersloh, S. B.; Zeitlin, C.; Miller, J.; Heilbronn, L.; Murakami, T.; Iwata, Y.; Chatterjee, A. (Principal Investigator)

    2002-01-01

    The radiation environment on board the space shuttle and the International Space Station includes high-Z and high-energy (HZE) particles that are part of the galactic cosmic radiation (GCR) spectrum. Iron-56 particles are considered to be one of the most biologically important parts of the GCR spectrum. Tissue-equivalent proportional counters (TEPCs) are used as active dosimeters on manned space flights. These TEPCs are further used to determine the average quality factor for each space mission. A TEPC simulating a 1-microm-diameter sphere of tissue was exposed as part of a particle spectrometer to (56)Fe particles at energies from 200-1000 MeV/nucleon. The response of TEPCs in terms of mean lineal energy, y(F), and dose mean lineal energy, y(D), as well as the energy deposited at different impact parameters through the detector was determined for six different incident energies of (56)Fe particles in this energy range. Calculations determined that charged-particle equilibrium was achieved for each of the six experiments. Energy depositions at different impact parameters were calculated using a radial dose distribution model, and the results were compared to experimental data.

  4. Gravitational properties of light: The emission of counter-propagating laser pulses from an atom

    NASA Astrophysics Data System (ADS)

    Rätzel, Dennis; Wilkens, Martin; Menzel, Ralf

    2017-04-01

    The gravitational field of a laser pulse, although not detectable at the moment, has a special feature which continues to attract attention; cause and effect propagate with the same speed, the speed of light. One particular result of this feature is that the gravitational field of an emitted laser pulse and the gravitational effect of the emitter's energy-momentum change are intimately entangled. In this article, a specific example of an emission process is considered: An atom, modeled as a point mass, emits two counter-propagating pulses. The corresponding curvature and the effect on massive and massless test particles is discussed. A comparison is made with the metric corresponding to a spherically symmetric massive object that isotropically emits radiation; the Vaidya metric.

  5. Effects of ionizing radiation on bio-active plant extracts useful for preventing oxidative damages.

    PubMed

    Mulinacci, Nadia; Valletta, Alessio; Pasqualetti, Valentina; Innocenti, Marzia; Giuliani, Camilla; Bellumori, Maria; De Angelis, Giulia; Carnevale, Alessia; Locato, Vittoria; Di Venanzio, Cristina; De Gara, Laura; Pasqua, Gabriella

    2018-04-02

    Humans are exposed to ionizing radiations in medical radiodiagnosis and radiotherapy that cause oxidative damages and degenerative diseases. Airplane pilots, and even more astronauts, are exposed to a variety of potentially harmful factors, including cosmic radiations. Among the phytochemicals, phenols are particularly efficient in countering the oxidative stress. In the present study, different extracts obtained from plant food, plant by-products and dietary supplements, have been compared for their antioxidant properties before and after irradiation of 140 cGy, a dose absorbed during a hypothetical stay of three years in the space. All the dry extracts, characterized in terms of vitamin C and phenolic content, remained chemically unaltered and maintained their antioxidant capability after irradiation. Our results suggest the potential use of these extracts as nutraceuticals to protect humans from oxidative damages, even when these extracts must be stored in an environment exposed to cosmic radiations as in a space station.

  6. Sulforaphane mitigates genotoxicity induced by radiation and anticancer drugs in human lymphocytes.

    PubMed

    Katoch, Omika; Kumar, Arun; Adhikari, Jawahar S; Dwarakanath, Bilikere S; Agrawala, Paban K

    2013-12-12

    Sulforaphane, present in cruciferous vegetables such as broccoli, is a dietary anticancer agent. Sulforaphane, added 2 or 20 h following phytohemaglutinin stimulation to cultured peripheral blood lymphocytes of individuals accidentally exposed to mixed γ and β-radiation, reduced the micronucleus frequency by up to 70%. Studies with whole blood cultures obtained from healthy volunteers confirmed the ability of sulforaphane to ameliorate γ-radiation-induced genotoxicity and to reduce micronucleus induction by other DNA-damaging anticancer agents, such as bleomycin and doxorubicin. This reduction in genotoxicity in lymphocytes treated at the G(0) or G(1) stage suggests a role for sulforaphane in modulating DNA repair. Sulforaphane also countered the radiation-induced increase in lymphocyte HDAC activity, to control levels, when cells were treated 2 h after exposure, and enhanced histone H4 acetylation status. Sulforaphane post-irradiation treatment enhanced the CD 34(+)Lin(-) cell population in culture. Sulforaphane has therapeutic potential for management of the late effects of radiation. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rao, Nageswara S; Sen, Satyabrata; Berry, M. L..

    Domestic Nuclear Detection Office s (DNDO) Intelligence Radiation Sensors Systems (IRSS) program supported the development of networks of commercial-off-the-shelf (COTS) radiation counters for detecting, localizing, and identifying low-level radiation sources. Under this program, a series of indoor and outdoor tests were conducted with multiple source strengths and types, different background profiles, and various types of source and detector movements. Following the tests, network algorithms were replayed in various re-constructed scenarios using sub-networks. These measurements and algorithm traces together provide a rich collection of highly valuable datasets for testing the current and next generation radiation network algorithms, including the ones (tomore » be) developed by broader R&D communities such as distributed detection, information fusion, and sensor networks. From this multiple TeraByte IRSS database, we distilled out and packaged the first batch of canonical datasets for public release. They include measurements from ten indoor and two outdoor tests which represent increasingly challenging baseline scenarios for robustly testing radiation network algorithms.« less

  8. Chemical, optical and radiative characteristics of aerosols during haze episodes of winter in the North China Plain

    NASA Astrophysics Data System (ADS)

    Ding, Jing; Zhang, Yufen; Han, Suqin; Xiao, Zhimei; Wang, Jiao; Feng, Yinchang

    2018-05-01

    Aerosol and water vapor radiative forcings, shortwave atmospheric heating rates and longwave atmospheric cooling rates were determined based on in situ physical and chemical measurements of aerosol, associated with the Mie theory and a radiative transfer model, LOWTRAN7, during the two haze episodes in the winter of 2013 in Tianjin, China. The aerosol types considered in LOWTRAN7 included rural, urban, marine, desert and custom aerosols. The default ratio of the absorption coefficient to the extinction coefficient for urban aerosol in LOWTRAN7 was approximately double of those found in this work, implying the weaker absorption ability of aerosols in the North China Plain (NCP). Moreover, the aerosol is assumed to be evenly distributed below 1 km of planetary boundary layer (PBL) on hazy days in LOWTRAN7. If the default urban aerosol optical properties and extinction profile in LOWTRAN7 is employed directly, a larger energy imbalance between the atmosphere and surface is generated and the warming effect of the aerosol is magnified. Hence, modified urban aerosol optical properties were established to replace the corresponding parameters' database in LOWTRAN7. The aerosol extinction profiles were obtained based on a 255-m meteorological tower and observed results from the studies about Tianjin. In the NCP, the aerosol had little impact on atmospheric counter radiation. The water vapor is the crucial factor that affects atmospheric counter radiation. Both modified high shortwave heating rates and longwave cooling rates occur near the surface due to the abundance of aerosol and water vapor. The modified net atmospheric heating rate near the surface is 1.2 K d-1 on hazy days and 0.3 K d-1 on non-hazy days. Compared with the default urban aerosol optical properties and its vertical distribution in LOWTRAN7, the feedback effect of the modified urban aerosol on the boundary layer may not necessarily result in a stable lower atmosphere, but depends on the aerosol light absorption ability and its vertical distribution.

  9. Estimation of low-level neutron dose-equivalent rate by using extrapolation method for a curie level Am-Be neutron source.

    PubMed

    Li, Gang; Xu, Jiayun; Zhang, Jie

    2015-01-01

    Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am-Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am-Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. Copyright © 2014 Elsevier Ltd. All rights reserved.

  10. In-flight radiation measurements on STS-60

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Golightly, M. J.; Konradi, A.; Atwell, W.; Kern, J. W.; Cash, B.; Benton, E. V.; Frank, A. L.; Sanner, D.; Keegan, R. P.; hide

    1996-01-01

    A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

  11. LECTURES ON PHYSICS, BIOPHYSICS, AND CHEMISTRY FOR HIGH SCHOOL SCIENCE TEACHERS GIVEN AT THE ERNEST O. LAWRENCE RADIATION LABORATORY, BERKELEY, CALIFORNIA, JUNE-AUGUST 1959

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Calhoon, E.C.; Starring, P.W. eds.

    1959-08-01

    Lectures given at the Ernest 0. Lawrence Radiation Laboratory on physics, biophysics, and chemistry for high school science teachers are presented. Topics covered include a mathematics review, atomic physics, nuclear physics, solid-state physics, elementary particles, antiparticies, design of experiments, high-energy particle accelerators, survey of particle detectors, emulsion as a particle detector, counters used in high-energy physics, bubble chambers, computer programming, chromatography, the transuranium elements, health physics, photosynthesis, the chemistry and physics of virus, the biology of virus, lipoproteins and heart disease, origin and evolution of the solar system, the role of space satellites in gathering astronomical data, and radiation andmore » life in space. (M.C.G.)« less

  12. WE-D-17A-05: Measurement of Stray Radiation Within An Active Scanning Proton Therapy Facility: EURADOS WG9 Intercomparison Exercise of Active Dosimetry Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farah, J; Trompier, F; Stolarczyk, L

    2014-06-15

    Purpose: Intercomparison of active dosemeters in the measurement of stray radiation at the Trento active-scanning proton therapy facility. Methods: EURADOS WG9 carried out a large intercomparison exercise to test different dosemeters while measuring secondary neutrons within a 230 MeV scanned proton therapy facility. Detectors included two Bonner Sphere Spectrometers (BSS), three tissue equivalent proportional counters (TEPCHawk) and six rem-counters (Wendi II, Berthold, RadEye, a regular and an extended-range Anderson and Braun NM2B counters). Measurements of neutron ambient dose equivalents, H*(10), were done at several positions inside (8 positions) and outside (3 positions) the treatment room while irradiating a water tankmore » phantom with a 10 × 10 × 10 cc field. Results: A generally good agreement on H*(10) values was observed for the tested detectors. At distance of 2.25 m and angles 45°, 90° and 180° with respect to the beam axis, BSS and proportional counters agreed within 30%. Higher differences (up to 60%) were observed at the closest and farthest distances, i.e. at positions where detectors sensitivity, energy, fluence and angular response are highly dependent on neutron spectra (flux and energy). The highest neutron H*(10) value, ∼60 microSv/Gy, was measured at 1.15 m along the beam axis. H*(10) decreased significantly with the distance from the isocenter dropping to 1.1 microSv/Gy at 4.25 m and 90° from beam axis, ∼2 nanoSv/Gy at the entrance of the maze, 0.2 nanoSv/Gy at the door outside the room and below detection limit in the gantry control room and at an adjacent room. These values remain considerately lower than those of passively scattered proton beams. BSS and Hawk unfolded spectra provide valuable inputs when studying the response of each detector. Conclusion: TEPCs and BSS enable accurate measurements of stray neutrons while other rem-meters also give satisfactory results but require further improvements to reduce uncertainties.« less

  13. Radiation countermeasure agents: an update (2011 – 2014)

    PubMed Central

    Newman, Victoria L; Romaine, Patricia LP; Wise, Stephen Y; Seed, Thomas M

    2014-01-01

    Introduction Despite significant scientific advances over the past 60 years towards the development of a safe, nontoxic and effective radiation countermeasure for the acute radiation syndrome (ARS), no drug has been approved by the US FDA. A radiation countermeasure to protect the population at large from the effects of lethal radiation exposure remains a significant unmet medical need of the US citizenry and, thus, has been recognized as a high priority area by the government. Area covered This article reviews relevant publications and patents for recent developments and progress for potential ARS treatments in the area of radiation countermeasures. Emphasis is placed on the advanced development of existing agents since 2011 and new agents identified as radiation countermeasure for ARS during this period. Expert opinion A number of promising radiation countermeasures are currently under development, seven of which have received US FDA investigational new drug status for clinical investigation. Four of these agents, CBLB502, Ex-RAD, HemaMax and OrbeShield, are progressing with large animal studies and clinical trials. G-CSF has high potential and well-documented therapeutic effects in countering myelosuppression and may receive full licensing approval by the US FDA in the future. PMID:25315070

  14. Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Woulfe, P.; O'Keeffe, S.; Sullivan, F. J.

    2018-02-01

    An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is developed, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 700μm of a 1mm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for low dose rate (LDR) brachytherapy, in prostate cancer treatment, providing radiation oncologists with real-time information of the radiation dose to the target area and/or nearby organs at risk (OARs). The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to 0.397mCi of Iodine125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.

  15. Microdosimetric investigation at the therapeutic proton beam facility of CATANA.

    PubMed

    De Nardo, L; Moro, D; Colautti, P; Conte, V; Tornielli, G; Cuttone, G

    2004-01-01

    Proton beams (62 Mev) are used by the Laboratori Nazionali del Sud of the Italian Institute of Nuclear Physics to treat eye melanoma tumours at the therapeutic facility called CATANA. A cylindrical slim tissue-equivalent proportional counter (TEPC) of 2.7 mm external diameter has been used to compare the radiation quality of two spread-out Bragg peaks (SOBP) at the CATANA proton beam.

  16. Support of research in X-ray astronomy

    NASA Technical Reports Server (NTRS)

    Garmire, G.

    1983-01-01

    Activities described include: (1) the evaluation of CCD detectors for X-ray astronomy applications; (2) contributions to the development of an imaging gas scintillation proportional counter; (3) the evaluation of certain metal oxide crystals as potential radiation detectors; (4) optical observations and searches for X-ray sources discovered by the HEAO-1 A2 experiment; and (5) theoretical modeling of nonequilibrium ionization structure of supernova remnants.

  17. Kuipers sets up the EHS/TEPC Spectrometer and Detector Assembly in the SM

    NASA Image and Video Library

    2012-03-12

    ISS030-E-177101 (12 March 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, sets up the Environmental Health System / Tissue Equivalent Proportional Counter (EHS/TEPC) spectrometer and detector assembly on panel 327 in the Zvezda Service Module of the International Space Station. The TEPC detector assembly is the primary radiation measurement tool on the space station.

  18. Measuring the iron spectral opacity in solar conditions using a double ablation front scheme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colaitis, A.; Ducret, J. E.; Turck-Chieze, S

    We propose a new method to achieve hydrodynamic conditions relevant for the investigation of the radiation transport properties of the plasma at the base of the solar convection zone. The method is designed in the framework of opacity measurements with high-power lasers and exploits the temporal and spatial stability of hydrodynamic parameters in counter-propagating Double Ablation Front (DAF) structures.

  19. Initial Results from the Radiation Dosimetry Experiment (RaD-X) Balloon Flight Mission

    NASA Technical Reports Server (NTRS)

    Mertens, Christopher J.

    2015-01-01

    The NASA Radiation Dosimetry Experiment (RaD-X) high-altitude balloon mission was successfully launched from Fort Sumner, New Mexico USA on 25 September, 2015. Over 15 hours of science data were obtained from four dosimeters at altitudes above about 25 km. The four dosimeters flown on the RaD-X science payload are a Hawk version 3.0 Tissue Equivalent Proportional Counter (TEPC) manufactured by Far West Technologies, a Liulin dosimeter-spectrometer produced by the Solar Research and Technology Institute, Bulgarian Academy of Sciences, a total ionizing dose detector manufactured by Teledyne Microelectronic Technologies, and the RaySure detector provided by the University of Surrey.

  20. NEUTRON COUNTER

    DOEpatents

    Curtis, C.D.; Carlson, R.L.; Tubinis, M.P.

    1958-07-29

    An ionization chamber instrument is described for cylindrical electrodes with an ionizing gag filling the channber. The inner electrode is held in place by a hermetic insulating seal at one end of the outer electrode, the other end of the outer electrode being closed by a gas filling tube. The outer surface of the inner electrode is coated with an active material which is responsive to neutron bombardment, such as uranium235 or boron-10, to produce ionizing radiations in the gas. The transverse cross sectional area of the inner electrode is small in relation to that of the channber whereby substantially all of the radiations are directed toward the outer electrode.

  1. Amelioration of radiation-induced pulmonary fibrosis by a water-soluble bifunctional sulfoxide radiation mitigator (MMS350).

    PubMed

    Kalash, Ronny; Epperly, Michael W; Goff, Julie; Dixon, Tracy; Sprachman, Melissa M; Zhang, Xichen; Shields, Donna; Cao, Shaonan; Franicola, Darcy; Wipf, Peter; Berhane, Hebist; Wang, Hong; Au, Jeremiah; Greenberger, Joel S

    2013-11-01

    A water-soluble ionizing radiation mitigator would have considerable advantages for the management of acute and chronic effects of ionizing radiation. We report that a novel oxetanyl sulfoxide (MMS350) is effective both as a protector and a mitigator of clonal mouse bone marrow stromal cell lines in vitro, and is an effective in vivo mitigator when administered 24 h after 9.5 Gy (LD100/30) total-body irradiation of C57BL/6NHsd mice, significantly improving survival (P = 0.0097). Furthermore, MMS350 (400 μM) added weekly to drinking water after 20 Gy thoracic irradiation significantly decreased: expression of pulmonary inflammatory and profibrotic gene transcripts and proteins; migration into the lungs of bone marrow origin luciferase+/GFP+ (luc+/GFP+) fibroblast progenitors (in both luc+ marrow chimeric and luc+ stromal cell line injected mouse models) and decreased radiation-induced pulmonary fibrosis (P < 0.0001). This nontoxic and orally administered small molecule may be an effective therapeutic in clinical radiotherapy and as a counter measure against the acute and chronic effects of ionizing radiation.

  2. Amelioration of Radiation-Induced Pulmonary Fibrosis by a Water-Soluble Bifunctional Sulfoxide Radiation Mitigator (MMS350)

    PubMed Central

    Kalash, Ronny; Epperly, Michael W.; Goff, Julie; Dixon, Tracy; Sprachman, Melissa M.; Zhang, Xichen; Shields, Donna; Cao, Shaonan; Franicola, Darcy; Wipf, Peter; Berhane, Hebist; Wang, Hong; Au, Jeremiah; Greenberger, Joel S.

    2014-01-01

    A water-soluble ionizing radiation mitigator would have considerable advantages for the management of acute and chronic effects of ionizing radiation. We report that a novel oxetanyl sulfoxide (MMS350) is effective both as a protector and a mitigator of clonal mouse bone marrow stromal cell lines in vitro, and is an effective in vivo mitigator when administered 24 h after 9.5 Gy (LD100/30) total-body irradiation of C57BL/6NHsd mice, significantly improving survival (P =0.0097). Furthermore, MMS350 (400 μM) added weekly to drinking water after 20 Gy thoracic irradiation significantly decreased: expression of pulmonary inflammatory and profibrotic gene transcripts and proteins; migration into the lungs of bone marrow origin luciferase+/GFP+ (luc+/GFP+) fibroblast progenitors (in both luc+ marrow chimeric and luc+ stromal cell line injected mouse models) and decreased radiation-induced pulmonary fibrosis (P < 0.0001). This nontoxic and orally administered small molecule may be an effective therapeutic in clinical radiotherapy and as a counter measure against the acute and chronic effects of ionizing radiation. PMID:24125487

  3. Vehicle-mounted high-power microwave systems and health risk communication in a deployed environment.

    PubMed

    Westhoff, John L; Roberts, Brad J; Erickson, Kristin

    2013-01-01

    Vehicle-mounted high-power microwave systems have been developed to counter the improvised explosive device threat in southwest Asia. Many service members only vaguely comprehend the nature of these devices and the nonionizing radio frequency (RF) radiation they emit. Misconceptions about the health effects of RF radiation have the potential to produce unnecessary anxiety. We report an incident in which concern for exposure to radiation from a high-power microwave device thought to be malfunctioning led to an extensive field investigation, multiple evaluations by clinicians in theater, and subsequent referrals to an Occupational Health clinic upon return from deployment. When acute exposure to RF does occur, the effects are thermally mediated and immediately perceptible--limiting the possibility of injury. Unlike ionizing radiation, RF radiation is not known to cause cancer and the adverse health effects are not cumulative. Medical officers counseling service members concerned about potential RF radiation exposure should apply established principles of risk communication, attend to real and perceived risks, and enlist the assistance of technical experts to properly characterize an exposure when appropriate.

  4. Two CMOS gate arrays for the EPACT experiment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Winkert, G.

    1992-08-01

    Two semicustom CMOS digital gate arrays are described in this paper which have been developed for the Energetic Particles: Acceleration, Composition, and Transport (EPACT) experiment. The first device, the 'Event Counters: 16 by 24-bit' (EC1624), implements sixteen 24-bit ripple counters and has flexible counting and readout options. The second device, the 'Serial Transmitter/Receiver' (SXR), is a multi-personality chip that can be used at either end of a serial, synchronous communications data link. It can be configured as a master in a central control unit, or as one of many slaves within remote assemblies. Together a network of SXRs allows formore » commanding and verification of distributed control signals. Both gate arrays are radiation hardened and qualified for space flight use. The architecture of each chip is presented and the benefits to the experiment summarized.« less

  5. Electron spin polarization in realistic trajectories around the magnetic node of two counter-propagating, circularly polarized, ultra-intense lasers

    NASA Astrophysics Data System (ADS)

    Del Sorbo, D.; Seipt, D.; Thomas, A. G. R.; Ridgers, C. P.

    2018-06-01

    It has recently been suggested that two counter-propagating, circularly polarized, ultra-intense lasers can induce a strong electron spin polarization at the magnetic node of the electromagnetic field that they setup (Del Sorbo et al 2017 Phys. Rev. A 96 043407). We confirm these results by considering a more sophisticated description that integrates over realistic trajectories. The electron dynamics is weakly affected by the variation of power radiated due to the spin polarization. The degree of spin polarization differs by approximately 5% if considering electrons initially at rest or already in a circular orbit. The instability of trajectories at the magnetic node induces a spin precession associated with the electron migration that establishes an upper temporal limit to the polarization of the electron population of about one laser period.

  6. Quality management system and accreditation of the in vivo monitoring laboratory at Karslruhe Institute of Technology.

    PubMed

    Breustedt, B; Mohr, U; Biegard, N; Cordes, G

    2011-03-01

    The in vivo monitoring laboratory (IVM) at Karlsruhe Institute of Technology (KIT), with one whole body counter and three partial-body counters, is an approved lab for individual monitoring according to German regulation. These approved labs are required to prove their competencies by accreditation to ISO/IEC 17025:2005. In 2007 a quality management system (QMS), which was successfully audited and granted accreditation, was set up at the IVM. The system is based on the ISO 9001 certified QMS of the central safety department of the Research Centre Karlsruhe the IVM belonged to at that time. The system itself was set up to be flexible and could be adapted to the recent organisational changes (e.g. founding of KIT and an institute for radiation research) with only minor effort.

  7. Cloud Condensation Nuclei Particle Counter (CCN) Instrument Handbook

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uin, Janek

    2016-04-01

    The Cloud Condensation Nuclei Counter—CCN (Figure 1) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility instrument for measuring the concentration of aerosol particles that can act as cloud condensation nuclei [1, 2]. The CCN draws the sample aerosol through a column with thermodynamically unstable supersaturated water vapor that can condense onto aerosol particles. Particles that are activated, i.e., grown larger in this process, are counted (and sized) by an Optical Particle Counter (OPC). Thus, activated ambient aerosol particle number concentration as a function of supersaturation is measured. Models CCN-100 and CCN-200 differ only inmore » the number of humidifier columns and related subsystems: CCN-100 has one column and CCN-200 has two columns along with dual flow systems and electronics.« less

  8. Crystallization and preliminary X-ray diffraction study of recombinant ribokinase from Thermus Species 2.9

    NASA Astrophysics Data System (ADS)

    Abramchik, Yu. A.; Timofeev, V. I.; Muravieva, T. I.; Esipov, R. S.; Kuranova, I. P.

    2016-11-01

    Ribokinase from a thermophilic strain of Thermus species 2.9 belonging to the carbohydrate ribokinase family (EC 2.7.1.15) was isolated, purified, and crystallized. The crystallization conditions were found by the vapor-diffusion technique and were then optimized to apply the capillary counter-diffusion technique. The X-ray diffraction data set was collected from the crystals, which were grown by the counter-diffusion technique, at the SPring-8 synchrotron radiation facility to 2.87 Å resolution. The crystals belong to sp. gr. P1211 and have the following unit-cell parameters: a = 81.613 Å, b = 156.132 Å, c = 87.714 Å, α = γ = 90°, β = 103.819°. The X-ray diffraction data set is suitable for determining the three-dimensional structure of the protein by the molecular-replacement method.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, Jeter C.; Aalseth, Craig E.; Bonicalzi, Ricco

    Age dating groundwater and seawater using 39Ar/Ar ratios is an important tool to understand water mass flow rates and mean residence time. For modern or contemporary argon, the 39Ar activity is 1.8 mBq per liter of argon. Radiation measurements at these activity levels require ultra low-background detectors. Low-background proportional counters have been developed at Pacific Northwest National Laboratory. These detectors use traditional mixtures of argon and methane as counting gas, and the residual 39Ar from commercial argon has become a predominant source of background activity in these detectors. We demonstrated sensitivity to 39Ar by using geological or ancient argon frommore » gas wells in place of commercial argon. The low level counting performance of these proportional counters is then demonstrated for sensitivities to 39Ar/Ar ratios sufficient to date water masses as old as 1000 years.« less

  10. Handbook of X-Ray Astronomy

    NASA Technical Reports Server (NTRS)

    Arnaud, Keith A. (Editor); Smith, Randall K.; Siemiginowska, Aneta

    2011-01-01

    X-ray astronomy was born in the aftermath of World War II as military rockets were repurposed to lift radiation detectors above the atmosphere for a few minutes at a time. These early flights detected and studied X-ray emission from the Solar corona. The first sources beyond the Solar System were detected during a rocket flight in 1962 by a team headed by Riccardo Giaccom at American Science and Engineering, a company founded by physicists from MIT. The rocket used Geiger counters with a system designed to reduce non-X-ray backgrounds and collimators limiting the region of sky seen by the counters. As the rocket spun, the field of view (FOV) happened to pass over what was later found to be the brightest non-Solar X-ray source; later designated See X-1. It also detected a uniform background glow which could not be resolved into individual sources. A follow-up campaign using X-ray detectors with better spatial resolution and optical telescopes identified See X-1 as an interacting binary with a compact (neutron star) primary. This success led to further suborbital rocket flights by a number of groups. More X-ray binaries were discovered, as well as X-ray emission from supernova remnants, the radio galaxies M87 and Cygnus-A, and the Coma cluster. Detectors were improved and Geiger counters were replaced by proportional counters, which provided information about energy spectra of the sources. A constant challenge was determining precise positions of sources as only collimators were available.

  11. Annual Cycle of Cloud Forcing of Surface Radiation Budget

    NASA Technical Reports Server (NTRS)

    Wilber, Anne C.; Smith, G. Louis; Stackhouse, Paul W., Jr.; Gupta, Shashi K.

    2006-01-01

    The climate of the Earth is determined by its balance of radiation. The incoming and outgoing radiation fluxes are strongly modulated by clouds, which are not well understood. The Earth Radiation Budget Experiment (Barkstrom and Smith, 1986) provided data from which the effects of clouds on radiation at the top of the atmosphere (TOA) could be computed (Ramanathan, 1987). At TOA, clouds increase the reflected solar radiation, tending to cool the planet, and decrease the OLR, causing the planet to retain its heat (Ramanathan et al., 1989; Harrison et al., 1990). The effects of clouds on radiation fluxes are denoted cloud forcing. These shortwave and longwave forcings counter each other to various degrees, so that in the tropics the result is a near balance. Over mid and polar latitude oceans, cloud forcing at TOA results in large net loss of radiation. Here, there are large areas of stratus clouds and cloud systems associated with storms. These systems are sensitive to surface temperatures and vary strongly with the annual cycle. During winter, anticyclones form over the continents and move to the oceans during summer. This movement of major cloud systems causes large changes of surface radiation, which in turn drives the surface temperature and sensible and latent heat released to the atmosphere.

  12. Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Woulfe, P.; Sullivan, F. J.; O'Keeffe, S.

    2016-05-01

    An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is presented, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 250μm of a 500μm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for brachytherapy, in prostate cancer treatment, providing oncologists with real-time information of the radiation dose to the target area and/or nearby critical structures. The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to Iodine-125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.

  13. Optical Angular Motion Sensor

    DTIC Science & Technology

    1975-04-01

    wedge at 10 Hz Background Radiation Completed Input Power Partially Transients, ripple and reverse Completed polarity power tests not per- formed...cases, indicating that the ACC was functioning properly. The changes seen were attributed to wedge angles and birefringent effects in the attenuators...noise for testing and is not within the specified value. 9.5.2 Method 2 A counter-rotating wedge of 15 arc minutes total deflection was used to measure

  14. REDUCTION OF DOSES IN DIAGNOSTIC USES OF RADIOISOTOPES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, F.

    1960-03-01

    > A moderately low-level counting technique with anticoincidence gas- flow counter was developed for use in metabolic and diagnostic tracer studies with radioisotopes. Several important experiments and results were reported which have been carried out with reduced doses of tracer isotopes. A reduction of the tracer dose of ahout 1/30th of the present conventional doses was achieved which helps to minimize the chances of radiation hazards. (auth)

  15. MEASUREMENT OF TIME INTERVALS FOR TIME CORRELATED RADIOACTIVE DECAY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindeman, H.; Mornel, E.; Galil, U.

    1960-11-01

    The distribution of time intervals between successive counts was measured for radioactive decay in the thorium series. The measurements showed that the classical Marsden-Barratt law does not apply to this case of timecorrelated decay. They appeared, however, to be in agreement with the theory of Lindeman-Rosen, taking into account the fact that the counter receives only the radiation emitted in a solid angle near to 2 pi . (auth)

  16. FLUKA simulation of TEPC response to cosmic radiation.

    PubMed

    Beck, P; Ferrari, A; Pelliccioni, M; Rollet, S; Villari, R

    2005-01-01

    The aircrew exposure to cosmic radiation can be assessed by calculation with codes validated by measurements. However, the relationship between doses in the free atmosphere, as calculated by the codes and from results of measurements performed within the aircraft, is still unclear. The response of a tissue-equivalent proportional counter (TEPC) has already been simulated successfully by the Monte Carlo transport code FLUKA. Absorbed dose rate and ambient dose equivalent rate distributions as functions of lineal energy have been simulated for several reference sources and mixed radiation fields. The agreement between simulation and measurements has been well demonstrated. In order to evaluate the influence of aircraft structures on aircrew exposure assessment, the response of TEPC in the free atmosphere and on-board is now simulated. The calculated results are discussed and compared with other calculations and measurements.

  17. Multichannel Spectrometer of Time Distribution

    NASA Astrophysics Data System (ADS)

    Akindinova, E. V.; Babenko, A. G.; Vakhtel, V. M.; Evseev, N. A.; Rabotkin, V. A.; Kharitonova, D. D.

    2015-06-01

    For research and control of characteristics of radiation fluxes, radioactive sources in particular, for example, in paper [1], a spectrometer and methods of data measurement and processing based on the multichannel counter of time intervals of accident events appearance (impulses of particle detector) MC-2A (SPC "ASPECT") were created. The spectrometer has four independent channels of registration of time intervals of impulses appearance and correspondent amplitude and spectrometric channels for control along the energy spectra of the operation stationarity of paths of each of the channels from the detector to the amplifier. The registration of alpha-radiation is carried out by the semiconductor detectors with energy resolution of 16-30 keV. Using a spectrometer there have been taken measurements of oscillations of alpha-radiation 239-Pu flux intensity with a subsequent autocorrelative statistical analysis of the time series of readings.

  18. Design and adaptation of a folded split ring resonator antenna for use in an animal-borne sensor

    NASA Astrophysics Data System (ADS)

    Dodson, S. C.; Wiid, P. G.; Niesler, T. R.

    2018-03-01

    We present the design, optimisation and practical evaluation of a folded split ring resonator (FSRR) antenna for the purpose of radio communication with an animal-borne sensor. We show that the measurements agree with the simulated results and that we are able to produce an electrically small antenna with low mismatch, high radiation efficiency and a quasi-isotropic radiation pattern. We then adapt the topology of the design from a circular to a rectangular shape, to completely fit inside the sensor enclosure. A quasi-isotropic pattern is maintained as well as low mismatch by appropriate tuning. There is a decrease in radiation efficiency which may be countered by a thinner substrate and retuning. We conclude that the adapted FSRR antenna is a suitable design for our application.

  19. DEPRON dosimeter for ``Lomonosov'' satellite

    NASA Astrophysics Data System (ADS)

    Brilkov, Ivan; Vedenkin, Nikolay; Panasyuk, Mikhail; Amelyushkin, Aleksandr; Petrov, Vasily; Nechayev, Oleg; Benghin, Victor

    It is commonly known, that cosmic radiation generates negative impact on the human body during space flight. The structure of the radiation fields in the near-Earth space was studied during intensive research of recent decades. Huge number of dosimetry studies was conducted on manned and unmanned space vehicles in order to solve the problem of radiation safety humans during space flights. It should be noted that most of the measurements was made onboard the spacecrafts, flying along the orbits with inclination of up to 51.6 degrees. Due to the prospect of manned missions at the orbits with larger inclination it seems advisable to conduct preliminary detailed dosimetry measurements at high-altitude orbit, for which the "Lomonosov" satellite provides good opportunities. We chose a method of cosmic radiation dosimetry based on semiconductor detectors. Proposed in the late 70's this method is widely used onboard spacecraft, including full-time radiation monitoring onboard the ISS. Recently it has been improved, providing an opportunity to register not only the absorbed dose of charged particles radiation, but also range of their ionization losses. It allowed assessment of equivalent dose. Appropriate procedure based on using of a telescope consisting of two semiconductor detectors provided a basis of the developed unit. It should be noted that not only the charged particles contribute significantly in the equivalent dose, but also neutrons do. Semiconductor detectors have low sensitivity to neutron radiation and are not sufficient for detecting the expected flux of neutrons. It was therefore decided to add thermal neutrons counter to the developed device in order to provide an opportunity of estimation of neutron flux variations along the satellite trajectory. A gas-discharge counter SI-13N, operated in a mode of corona discharge was chosen as a neutron detector. This method of neutron detection is well-proven and used many times in SINP MSU experiments. Thus, the appearance of the instrument DEPRON (Dosimeter of Electrons, PROtons and Neutrons) was determined. DEPRON is intended for registration of the absorbed doses and linear energy transfer spectra for high-energy electrons, protons and nuclei of space radiation, as well as registration of thermal and slow neutrons. The experiment based on DEPRON instrument is aimed at the studies of the distribution of space radiation dose rate at high latitude paths in order to study the flight paths of perspective manned spacecraft. Present work provides a brief description of the DEPRON instrument, its calibration results and the structure of the output data.

  20. AUTOMATIC HAND COUNTER

    DOEpatents

    Mann J.R.; Wainwright, A.E.

    1963-06-11

    An automatic, personnel-operated, alpha-particle hand monitor is described which functions as a qualitative instrument to indicate to the person using it whether his hands are cold'' or hot.'' The monitor is activated by a push button and includes several capacitor-triggered thyratron tubes. Upon release of the push button, the monitor starts the counting of the radiation present on the hands of the person. If the count of the radiation exceeds a predetermined level within a predetermined time, then a capacitor will trigger a first thyratron tube to light a hot'' lamp. If, however, the count is below such level during this time period, another capacitor will fire a second thyratron to light a safe'' lamp. (AEC)

  1. Integrated Orbit, Attitude, and Structural Control System Design for Space Solar Power Satellites

    NASA Technical Reports Server (NTRS)

    Woods-Vedeler, Jessica (Technical Monitor); Moore, Chris (Technical Monitor); Wie, Bong; Roithmayr, Carlos

    2001-01-01

    The major objective of this study is to develop an integrated orbit, attitude, and structural control system architecture for very large Space Solar Power Satellites (SSPS) in geosynchronous orbit. This study focuses on the 1.2-GW Abacus SSPS concept characterized by a 3.2 x 3.2 km solar-array platform, a 500-m diameter microwave beam transmitting antenna, and a 500 700 m earth-tracking reflector. For this baseline Abacus SSPS configuration, we derive and analyze a complete set of mathematical models, including external disturbances such as solar radiation pressure, microwave radiation, gravity-gradient torque, and other orbit perturbation effects. The proposed control system architecture utilizes a minimum of 500 1-N electric thrusters to counter, simultaneously, the cyclic pitch gravity-gradient torque, the secular roll torque caused by an o.set of the center-of-mass and center-of-pressure, the cyclic roll/yaw microwave radiation torque, and the solar radiation pressure force whose average value is about 60 N.

  2. Integrated Orbit, Attitude, and Structural Control Systems Design for Space Solar Power Satellites

    NASA Technical Reports Server (NTRS)

    Wie, Bong; Roithmayr, Carlos M.

    2001-01-01

    The major objective of this study is to develop an integrated orbit, attitude, and structural control systems architecture for very large Space Solar Power Satellites (SSPS) in geosynchronous orbit. This study focuses on the 1.2-GW Abacus SSPS concept characterized by a 3.2 x 3.2 km solar-array platform, a 500-m diameter microwave beam transmitting antenna, and a 500 x 700 m earth-tracking reflector. For this baseline Abacus SSPS configuration, we derive and analyze a complete set of mathematical models, including external disturbances such as solar radiation pressure, microwave radiation, gravity-gradient torque, and other orbit perturbation effects. The proposed control systems architecture utilizes a minimum of 500 1-N electric thrusters to counter, simultaneously, the cyclic pitch gravity-gradient torque, the secular roll torque caused by an offset of the center-of-mass and center-of-pressure, the cyclic roll/yaw microwave radiation torque, and the solar radiation pressure force whose average value is about 60 N.

  3. Interaction of Superconducting YBa2Cu(sub 3-x)Zn(sub x)O(sub 7-y) with MeV Radiation

    NASA Technical Reports Server (NTRS)

    Lewis, R. A.; Robertson, G. A.

    2005-01-01

    When the high Tc superconductor Y-Ba-Cu-O is cooled with liquid nitrogen, the conduction holes form a macroscopic collective or entangled state. While collective effects have been observed with radiation energies up to 5 eV, no high-sensitivity experiments have previously been carried out to search for comparable effects with MeV radiation. Here an experiment using a pair of scintillation counters arranged to search for changes in the natural background of high energy radiation adjacent to a warm and cold Y-Ba-Cu-O superconductor is described. The experiment showed a shift toward higher pulse heights when the SC was cooled, with a 4 standard deviation excess of 9.12+/-2.28 events/ksec over the range of 0 to 18 MeV. The net difference spectrum shows a 5.5 standard deviation excess signal for the range of 3 to 6 MeV.

  4. Indoor External Radiation Risk in Densely Populated Regions of Southern Nigeria

    NASA Astrophysics Data System (ADS)

    Ife-Adediran, Oluwatobi O.; Uwadiae, Iyobosa B.

    2018-02-01

    It is known that certain types of building materials contain significant concentrations of natural radionuclides; consequently, exposure to indoor background radiation is from the combined radioactivity from the soil as well as building materials; indoor exposures therefore have higher radiation hazard potentials than outdoor exposures in this regard and hence, need to be monitored. In this paper, an evaluation of background ionizing radiation from different buildings in Lagos and Ibadan, Southwestern Nigeria was carried out to determine the exposure rate of the general public to indoor ionizing radiation. 630 in situ measurements from the different buildings were taken using a Geiger Muller counter (model GQ-320 Plus). The indoor dose rates (i.e., 50-120 nGy/h) were within the world average values while the Annual Effective Dose for most of the buildings were above the world average AED for indoor gamma exposure from building materials. The mean AED for Lagos and Ibadan due to indoor exposures were 0.37 and 0.39 mSv/y with Excess Lifetime Cancer Risk of 0.99E-3 and 1.05E-3, respectively.

  5. Indoor External Radiation Risk in Densely Populated Regions of Southern Nigeria

    NASA Astrophysics Data System (ADS)

    Ife-Adediran, Oluwatobi O.; Uwadiae, Iyobosa B.

    2018-05-01

    It is known that certain types of building materials contain significant concentrations of natural radionuclides; consequently, exposure to indoor background radiation is from the combined radioactivity from the soil as well as building materials; indoor exposures therefore have higher radiation hazard potentials than outdoor exposures in this regard and hence, need to be monitored. In this paper, an evaluation of background ionizing radiation from different buildings in Lagos and Ibadan, Southwestern Nigeria was carried out to determine the exposure rate of the general public to indoor ionizing radiation. 630 in situ measurements from the different buildings were taken using a Geiger Muller counter (model GQ-320 Plus). The indoor dose rates (i.e., 50-120 nGy/h) were within the world average values while the Annual Effective Dose for most of the buildings were above the world average AED for indoor gamma exposure from building materials. The mean AED for Lagos and Ibadan due to indoor exposures were 0.37 and 0.39 mSv/y with Excess Lifetime Cancer Risk of 0.99E-3 and 1.05E-3, respectively.

  6. Crystallization and preliminary X-ray diffraction study of recombinant ribokinase from Thermus Species 2.9

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abramchik, Yu. A.; Timofeev, V. I., E-mail: tostars@mail.ru; Muravieva, T. I.

    2016-11-15

    Ribokinase from a thermophilic strain of Thermus species 2.9 belonging to the carbohydrate ribokinase family (EC 2.7.1.15) was isolated, purified, and crystallized. The crystallization conditions were found by the vapor-diffusion technique and were then optimized to apply the capillary counter-diffusion technique. The X-ray diffraction data set was collected from the crystals, which were grown by the counter-diffusion technique, at the SPring-8 synchrotron radiation facility to 2.87 Å resolution. The crystals belong to sp. gr. P12{sub 1}1 and have the following unit-cell parameters: a = 81.613 Å, b = 156.132 Å, c = 87.714 Å, α = γ = 90°, βmore » = 103.819°. The X-ray diffraction data set is suitable for determining the three-dimensional structure of the protein by the molecular-replacement method.« less

  7. Ames collaborative study of cosmic ray neutrons

    NASA Technical Reports Server (NTRS)

    Hewitt, J. E.; Hughes, L.; Mccaslin, J. B.; Stephens, L. D.; Rindi, A.; Smith, A. R.; Thomas, R. H.; Griffith, R. V.; Welles, C. G.; Baum, J. W.

    1976-01-01

    The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

  8. Wireless smart meters and public acceptance: the environment, limited choices, and precautionary politics.

    PubMed

    Hess, David J; Coley, Jonathan S

    2014-08-01

    Wireless smart meters (WSMs) promise numerous environmental benefits, but they have been installed without full consideration of public acceptance issues. Although societal-implications research and regulatory policy have focused on privacy, security, and accuracy issues, our research indicates that health concerns have played an important role in the public policy debates that have emerged in California. Regulatory bodies do not recognize non-thermal health effects for non-ionizing electromagnetic radiation, but both homeowners and counter-experts have contested the official assurances that WSMs pose no health risks. Similarities and differences with the existing social science literature on mobile phone masts are discussed, as are the broader political implications of framing an alternative policy based on an opt-out choice. The research suggests conditions under which health-oriented precautionary politics can be particularly effective, namely, if there is a mandatory technology, a network of counter-experts, and a broader context of democratic contestation.

  9. Search for tachyons associated with extensive air showers in the ground level cosmic radiation

    NASA Technical Reports Server (NTRS)

    Masjed, H. F.; Ashton, F.

    1985-01-01

    Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.

  10. Bikini scientific resurvey. Volume II. Report of the technical director. Technical report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1947-12-01

    Contents: Island and Reef Geology; Submarine Geology; Drilling Operations; Radiobiology Studies; Reef and Lagoon Fishes; Pelagic Fishes; Taxonomy and Teratology of Fishes; Invertebrate Embryology; Vertebrate Embryology; Reef and Lagoon Algae; Chemical Effects of Organisms Upon Sea Water; The Insect Population; Marine Invertebrates; Land Animals; Plankton Studies; Counter-Room Activities; Radiochemical Analyses; Soils Chemistry; Low-Level Radiation Studies; Army Engineering Studies; Aerological Data; Bacteriological Investigations; Radiological Safety; Radiological Health; Technical Director's Summary.

  11. Force Enhancement Packages for Countering Nuclear Threats in the 2022-2027 Time Frame: Final Report

    DTIC Science & Technology

    2015-09-01

    survey, and area characterization methods . • Apply proper radioisotope identification techniques. A-10 c. A one-week CNT operations exercise at Fort...focus on experiments to seek better iv methods , holding active teaching until later. The team expects that better methods would involve collection... methods likely will involve collection by multiple ISR sensors and on-the-ground investigators, with only limited use of radiation detectors. The

  12. Radiation measurement platform for balloon flights based on the TriTel silicon detector telescope

    NASA Astrophysics Data System (ADS)

    Zabori, Balazs; Hirn, Attila; Pazmandi, Tamas; Apathy, Istvan; Szanto, Peter; Deme, Sandor

    Several measurements have been performed on the cosmic radiation field from the surface of the Earth up to the maximum altitudes of research airplanes. However the cosmic radiation field is not well known between 15 km and 30 km. Our experiment idea based on to study the radiation environment in the stratosphere. The main technical goals of our experiment were to test at first time the TriTel 3D silicon detector telescope system for future ISS missons and to develop a balloon technology platform for advanced cosmic radiation and dosimetric measurements. The main scientific goals were to give an assessment of the cosmic radiation field at the altitude of the BEXUS balloons, to use the TriTel system to determine dosimetric and radiation quantities during the ballon flight and to intercompare the TriTel and Pille results to provide a correction factor definition method for the Pille ISS measurements. To fulfil the scientific and technological objectives several different dosimeter systems were included in the experiment: an advanced version of the TriTel silicon detector telescope, Geiger-Müller counters, Pille passive thermoluminescent dosimeters and Solid State Nuclear Track Detectors. The experiment was built by students from Hungarian universities and flew on board the BEXUS stratospheric balloon in Northern Sweden (from ESRANGE Space Center). The float altitude was approximately 28.6 km and the total flight time was about 4 hours. The active instruments measured in real time and the ground team received the collected data continuously during the mission. The main technical goals were received since the operation of the TriTel experienced no failures and the experiment worked as it expected. This paper presents the scientific goals and results. From the TriTel measurements the deposited energy spectra, the Linear Energy Transfer spectra, the average quality factor of the cosmic radiation as well as the absorbed dose and the dose equivalent were determined for the three axis. TriTel data evaluation and error estimations were studied in details. The evaluated deposited energy spectra measured with the improved TriTel instrument were compared with the count rates measured with the GM counters to calibrate them for dose rate in the cosmic radiation field at the altitude of the stratospheric balloons. From the SSNTD results the contribution of thermal neutrons was determined. In the frame of the TriTel and Pille intercomparison a correction factor calculation method was determined for future ISS data evaluation. The results will be used in the future scientific data evaluation in case of the ISS measurements. As a future outlook a short overview will be given about planned rocket radiation experiments.

  13. On vortex-airfoil interaction noise including span-end effects, with application to open-rotor aeroacoustics

    NASA Astrophysics Data System (ADS)

    Roger, Michel; Schram, Christophe; Moreau, Stéphane

    2014-01-01

    A linear analytical model is developed for the chopping of a cylindrical vortex by a flat-plate airfoil, with or without a span-end effect. The major interest is the contribution of the tip-vortex produced by an upstream rotating blade in the rotor-rotor interaction noise mechanism of counter-rotating open rotors. Therefore the interaction is primarily addressed in an annular strip of limited spanwise extent bounding the impinged blade segment, and the unwrapped strip is described in Cartesian coordinates. The study also addresses the interaction of a propeller wake with a downstream wing or empennage. Cylindrical vortices are considered, for which the velocity field is expanded in two-dimensional gusts in the reference frame of the airfoil. For each gust the response of the airfoil is derived, first ignoring the effect of the span end, assimilating the airfoil to a rigid flat plate, with or without sweep. The corresponding unsteady lift acts as a distribution of acoustic dipoles, and the radiated sound is obtained from a radiation integral over the actual extent of the airfoil. In the case of tip-vortex interaction noise in CRORs the acoustic signature is determined for vortex trajectories passing beyond, exactly at and below the tip radius of the impinged blade segment, in a reference frame attached to the segment. In a second step the same problem is readdressed accounting for the effect of span end on the aerodynamic response of a blade tip. This is achieved through a composite two-directional Schwarzschild's technique. The modifications of the distributed unsteady lift and of the radiated sound are discussed. The chained source and radiation models provide physical insight into the mechanism of vortex chopping by a blade tip in free field. They allow assessing the acoustic benefit of clipping the rear rotor in a counter-rotating open-rotor architecture.

  14. X-ray absorption fine structure (XAFS) spectroscopy using synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Shrivastava, B. D.

    2012-05-01

    The X-ray absorption fine structure (XAFS) spectra are best recorded when a highly intense beam of X-rays from a synchrotron is used along with a good resolution double crystal or curved crystal spectrometer and detectors like ionization chambers, scintillation counters, solid state detectors etc. Several synchrotrons around the world have X-ray beamlines dedicated specifically to XAFS spectroscopy. Fortunately, the Indian synchrotron (Indus-2) at Raja Ramanna Centre for Advanced Technology (RRCAT) at Indore has started operation. A dispersive type EXAFS beamline called BL-8 has been commissioned at this synchrotron and another beamline having double crystal monochromator (DCM) is going to be commissioned shortly. In Indian context, in order that more research workers use these beamlines, the study of XAFS spectroscopy using synchrotron radiation becomes important. In the present work some of the works done by our group on XAFS spectroscopy using synchrotron radiation have been described.

  15. Nurse exposure doses resulted from bone scintigraphy patient

    NASA Astrophysics Data System (ADS)

    Tunçman, Duygu; Kovan, Bilal; Poyraz, Leyla; ćapali, Veli; Demir, Bayram; Türkmen, Cüneyt

    2016-03-01

    Bone scintigraphy is used for displaying the radiologic undiagnosed bone lesions in nuclear medicine. It's general indications are researching bone metastases, detection of radiographically occult fractures, staging and follow-up in primary bone tumors, diagnosis of paget's disease, investigation of loosening and infection in orthopedic implants. It is applied with using 99mTc labeled radiopharmaceuticals (e.g 99m Tc MDP,99mTc HEDP and 99mTc HMDP). 20 -25 mCi IV radiotracer was injected into vein and radiotracer emits gamma radiation. Patient waits in isolated room for about 3 hours then a gamma camera scans radiation area and creates an image. When some patient's situation is not good, patients are hospitalized until the scanning because of patients' close contact care need. In this study, measurements were taken from ten patients using Geiger Muller counter. After these measurements, we calculated nurse's exposure radiations from patient's routine treatment, examination and emergency station.

  16. Using smartphones and tablet PCs for β--spectroscopy in an educational experimental setup

    NASA Astrophysics Data System (ADS)

    Gröber, Sebastian; Molz, Alexander; Kuhn, Jochen

    2014-11-01

    A magnetic spectrometer is used to gather the β--spectrum of 90 Sr /Y with a focus on two aspects. (1) The intensity of β--radiation is measured by the camera sensor module of a tablet PC together with the RadioactivityCounter app and by a Geiger-Müller tube. We evaluate the quality of mobile devices as radioactive radiation detectors by using polyenergetic β--radiation as an example and by comparing the spectra measured with the two detector types. (2) For educational purposes we implement a simple experimental setup, which consists of separate devices for measuring the electron’s kinetic energy and intensity, which are available in laboratories in educational settings. Comparison of the measured β--spectra published in the literature should encourage students to think about the energy resolution power of the β--spectrometer. Theoretical considerations show the low, yet sufficient energy resolution power of this spectrometer, especially for low energy levels.

  17. Effect of Radiological Countermeasures on Subjective Well-Being and Radiation Anxiety after the 2011 Disaster: The Fukushima Health Management Survey.

    PubMed

    Murakami, Michio; Takebayashi, Yoshitake; Takeda, Yoshihito; Sato, Akiko; Igarashi, Yasumasa; Sano, Kazumi; Yasutaka, Tetsuo; Naito, Wataru; Hirota, Sumire; Goto, Aya; Ohira, Tetsuya; Yasumura, Seiji; Tanigawa, Koichi

    2018-01-12

    After the Fukushima Daiichi Nuclear Power Station accident in 2011, concerns about radiation exposure and decline in subjective well-being have been reported. To tackle these problems, various countermeasures in relation to radiation have been implemented. In this study, we comprehensively evaluated the effects of radiological countermeasures on subjective well-being (e.g., satisfaction with life (SWL) and emotional well-being) and radiation anxiety, through a questionnaire survey targeting Fukushima residents ( N = 1023). Propensity scores matching was applied to evaluate significant effects of radiological countermeasures on subjective well-being and radiation anxiety. Among the radiological countermeasures, thyroid examination, whole body counter, and air dose monitoring showed the highest proportions of participation, utilization, and useful evaluation, suggesting a high degree of public attention focused on these countermeasures. The basic survey was associated with significant increases in SWL and self-rated health (SH). Thyroid examination was significantly associated with not only a reduction in radiation anxiety but also an increase of emotional stress, suggesting the importance of careful design of system and detailed communication. Food inspection was associated with deterioration in SH. Those who utilized explanatory meetings showed increases in sadness, worry, and radiation anxiety, indicating that additional attention is required of the experts and authorities involved in explanatory meetings.

  18. Effect of Radiological Countermeasures on Subjective Well-Being and Radiation Anxiety after the 2011 Disaster: The Fukushima Health Management Survey

    PubMed Central

    Murakami, Michio; Takeda, Yoshihito; Sato, Akiko; Igarashi, Yasumasa; Sano, Kazumi; Yasutaka, Tetsuo; Naito, Wataru; Hirota, Sumire; Goto, Aya; Ohira, Tetsuya; Yasumura, Seiji; Tanigawa, Koichi

    2018-01-01

    After the Fukushima Daiichi Nuclear Power Station accident in 2011, concerns about radiation exposure and decline in subjective well-being have been reported. To tackle these problems, various countermeasures in relation to radiation have been implemented. In this study, we comprehensively evaluated the effects of radiological countermeasures on subjective well-being (e.g., satisfaction with life (SWL) and emotional well-being) and radiation anxiety, through a questionnaire survey targeting Fukushima residents (N = 1023). Propensity scores matching was applied to evaluate significant effects of radiological countermeasures on subjective well-being and radiation anxiety. Among the radiological countermeasures, thyroid examination, whole body counter, and air dose monitoring showed the highest proportions of participation, utilization, and useful evaluation, suggesting a high degree of public attention focused on these countermeasures. The basic survey was associated with significant increases in SWL and self-rated health (SH). Thyroid examination was significantly associated with not only a reduction in radiation anxiety but also an increase of emotional stress, suggesting the importance of careful design of system and detailed communication. Food inspection was associated with deterioration in SH. Those who utilized explanatory meetings showed increases in sadness, worry, and radiation anxiety, indicating that additional attention is required of the experts and authorities involved in explanatory meetings. PMID:29329263

  19. Assessment of the Influence of the RaD-X Balloon Payload on the Onboard Radiation Detectors

    NASA Technical Reports Server (NTRS)

    Gronoff, Guilluame; Mertens, Christopher J.; Norman, Ryan B.; Straume, Tore; Lusby, Terry C.

    2016-01-01

    The NASA Radiation Dosimetry Experiment (RaD-X) stratospheric balloon flight mission, launched on 25 September 2015, provided dosimetric measurements above the Pfotzer maximum. The goal of taking these measurements is to improve aviation radiation models by providing a characterization of cosmic ray primaries, which are the source of radiation exposure at aviation altitudes. The RaD-X science payload consists of four instruments. The main science instrument is a tissue-equivalent proportional counter (TEPC). The other instruments consisted of three solid state silicon dosimeters: Liulin, Teledyne total ionizing dose (TID) and RaySure detectors. The instruments were housed in an aluminum structure protected by a foam cover. The structure partially shielded the detectors from cosmic rays but also created secondary particles, modifying the ambient radiation environment observed by the instruments. Therefore, it is necessary to account for the influence of the payload structure on the measured doses. In this paper, we present the results of modeling the effect of the balloon payload on the radiation detector measurements using a Geant-4 (GEometry ANd Tracking) application. Payload structure correction factors derived for the TEPC, Liulin, and TID instruments are provided as a function of altitude. Overall, the payload corrections are no more than a 7% effect on the radiation environment measurements.

  20. Assessment of the effects of environmental radiation on wind chill equivalent temperatures.

    PubMed

    Shitzer, Avraham

    2008-09-01

    Combinations of wind-driven convection and environmental radiation in cold weather, make the environment "feel" colder. The relative contributions of these mechanisms, which form the basis for estimating wind chill equivalent temperatures (WCETs), are studied over a wide range of environmental conditions. Distinction is made between direct solar radiation and environmental radiation. Solar radiation, which is not included in the analysis, has beneficial effects, as it counters and offsets some of the effects due to wind and low air temperatures. Environmental radiation effects, which are included, have detrimental effects in enhancing heat loss from the human body, thus affecting the overall thermal sensation due to the environment. The analysis is performed by a simple, steady-state analytical model of human-environment thermal interaction using upper and lower bounds of environmental radiation heat exchange. It is shown that, over a wide range of relevant air temperatures and reported wind speeds, convection heat losses dominate over environmental radiation. At low wind speeds radiation contributes up to about 23% of the overall heat loss from exposed skin areas. Its relative contributions reduce considerably as the time of the exposure prolongs and exposed skin temperatures drop. At still higher wind speeds, environmental radiation effects become much smaller contributing about 5% of the total heat loss. These values fall well within the uncertainties associated with the parameter values assumed in the computation of WCETs. It is also shown that environmental radiation effects may be accommodated by adjusting reported wind speeds slightly above their reported values.

  1. Active Interrogation of Depleted Uranium Using a Single Pulse, High-Intensity Photon and Mixed Photon-Neutron Source

    NASA Astrophysics Data System (ADS)

    Clemett, Ceri D.; Martin, Philip N.; Hill, Cassie; Threadgold, James R.; Maddock, Robert C.; Campbell, Ben; O'Malley, John; Woolf, Richard S.; Phlips, Bernard F.; Hutcheson, Anthony L.; Wulf, Eric A.; Zier, Jacob C.; Jackson, Stuart L.; Commisso, Robert J.; Schumer, Joseph W.

    2015-04-01

    Active interrogation is a method used to enhance the likelihood of detection of shielded special nuclear material (SNM); an external source of radiation is used to interrogate a target and to stimulate fission within any SNM present. Radiation produced by the fission process can be detected and used to infer the presence of the SNM. The Atomic Weapons Establishment (AWE) and the Naval Research Laboratory (NRL) have carried out a joint experimental study into the use of single pulse, high-intensity sources of bremsstrahlung x-rays and D(γb, n)H photoneutrons in an active interrogation system. The source was operated in both x-ray-only and mixed x-ray/photoneutron modes, and was used to irradiate a depleted uranium (DU) target which was enclosed by up to 150 g·cm - 2 of steel shielding. Resulting radiation signatures were measured by a suite of over 80 detectors and the data used to characterise detectable fission signatures as a function of the areal mass of the shielding. This paper describes the work carried out and discusses data collected with 3He proportional counters, NaI(Tl) scintillators and Eljen EJ-309 liquid scintillators. Results with the x-ray-only source demonstrate detection ( > 3\\sigmab) of the DU target through a minimum of 113 g·cm - 2 of steel, dropping to 85 g·cm- 2 when using a mixed x-ray/photoneutron source. The 3He proportional counters demonstrate detection ( > 3\\sigmab) of the DU target through the maximum 149. 7 g·cm - 2 steel shielding deployed for both photon and mixed x-ray/photoneutron sources.

  2. Definition phase study of the grand tour missions

    NASA Technical Reports Server (NTRS)

    Simpson, J. A.; Meyer, P.

    1972-01-01

    The research to define an energetic particle experiment for the OPTGT-MJS missions is reported. The studies reported include: (1) the use of silicon dectectors for low energy, low flux level measurements in the presence of RTG radiation and trapped electrons, (2) high energy proton damage of lithium-drifted and surface barrier silicon detectors, (3) the gas Cerenkov counter, (4) systems for detection of trapped high-energy protons in the presence of trapped electrons, and (5) reliability and redundancy.

  3. Improved Technology To Prevent Nuclear Proliferation And Counter Nuclear Terrorism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richardson, J; Yuldashev, B; Labov, S

    2006-06-12

    As the world moves into the 21st century, the possibility of greater reliance on nuclear energy will impose additional technical requirements to prevent proliferation. In addition to proliferation resistant reactors, a careful examination of the various possible fuel cycles from cradle to grave will provide additional technical and nonproliferation challenges in the areas of conversion, enrichment, transportation, recycling and waste disposal. Radiation detection technology and information management have a prominent role in any future global regime for nonproliferation. As nuclear energy and hence nuclear materials become an increasingly global phenomenon, using local technologies and capabilities facilitate incorporation of enhanced monitoringmore » and detection on the regional level. Radiation detection technologies are an important tool in the prevention of proliferation and countering radiological/nuclear terrorism. A variety of new developments have enabled enhanced performance in terms of energy resolution, spatial resolution, passive detection, predictive modeling and simulation, active interrogation, and ease of operation and deployment in the field. For example, various gamma ray imaging approaches are being explored to combine spatial resolution with background suppression in order to enhance sensitivity many-fold at reasonable standoff distances and acquisition times. New materials and approaches are being developed in order to provide adequate energy resolution in field use without the necessity for liquid nitrogen. Different detection algorithms enable fissile materials to be distinguished from other radioisotopes.« less

  4. Spatial fragment distribution from a therapeutic pencil-like carbon beam in water.

    PubMed

    Matsufuji, Naruhiro; Komori, Masataka; Sasaki, Hitomi; Akiu, Kengo; Ogawa, Masako; Fukumura, Akifumi; Urakabe, Eriko; Inaniwa, Taku; Nishio, Teiji; Kohno, Toshiyuki; Kanai, Tatsuaki

    2005-07-21

    The latest heavy ion therapy tends to require information about the spatial distribution of the quality of radiation in a patient's body in order to make the best use of any potential advantage of swift heavy ions for the therapeutic treatment of a tumour. The deflection of incident particles is described well by Molière's multiple-scattering theory of primary particles; however, the deflection of projectile fragments is not yet thoroughly understood. This paper reports on our investigation of the spatial distribution of fragments produced from a therapeutic carbon beam through nuclear reactions in thick water. A DeltaE-E counter telescope system, composed of a plastic scintillator, a gas-flow proportional counter and a BGO scintillator, was rotated around a water target in order to measure the spatial distribution of the radiation quality. The results revealed that the observed deflection of fragment particles exceeded the multiple scattering effect estimated by Molière's theory. However, the difference can be sufficiently accounted for by considering one term involved in the multiple-scattering formula; this term corresponds to a lateral 'kick' at the point of production of the fragment. This kick is successfully explained as a transfer of the intra-nucleus Fermi momentum of a projectile to the fragment; the extent of the kick obeys the expectation derived from the Goldhaber model.

  5. Cherenkov light imaging tests with state-of-the-art solid state photon counter for the CLAS12 RICH detector

    NASA Astrophysics Data System (ADS)

    Balossino, Ilaria; Barion, L.; Contalbrigo, M.; Lenisa, P.; Lucherini, V.; Malaguti, R.; Mirazita, M.; Movsisyan, A.; Squerzanti, S.; Turisini, M.

    2017-12-01

    A large area ring-imaging Cherenkov detector will be operated for hadron identification in the 3 GeV / c to 8 GeV / c momentum range at the CLAS12 experiment at the upgraded continuous electron beam accelerator facility of Jefferson Lab. The detector, consisting of aerogel radiator, composite mirrors and photon counters, will be built with a hybrid optics design to allow the detection of Cherenkov light for both forward and large angle hadron tracks. The active area has to be densely packed and highly segmented, covering about 1m2 with pixels of 6mm2 , and to allow a time resolution of 1 ns. A technology that can offer a cost-effective solution and low material budget could be Silicon Photomultipliers (SiPM) thanks to their high gain at low bias voltage, fast timing, good single-photoelectron resolution and insensitivity to magnetic fields. An investigation is ongoing on samples of 3 × 3mm2 SiPM of different micro-cell size to assess the single photon detection capability in the presence of high dark count rate due to thermal generation effects, after-pulses or optical cross-talk and to study the response to the moderate radiation damage expected at CLAS12. In this work, a brief review of the latest and most interesting results from these studies will be shown.

  6. Arduino based radiation survey meter

    NASA Astrophysics Data System (ADS)

    Rahman, Nur Aira Abd; Lombigit, Lojius; Abdullah, Nor Arymaswati; Azman, Azraf; Dolah, Taufik; Muzakkir, Amir; Jaafar, Zainudin; Mohamad, Glam Hadzir Patai; Ramli, Abd Aziz Mhd; Zain, Rasif Mohd; Said, Fazila; Khalid, Mohd Ashhar; Taat, Muhamad Zahidee

    2016-01-01

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr-1). Conversion factor (CF) value for conversion of CPM to μSvhr-1 determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The survey meter measurement results are found to be linear for dose rates below 3500 µSv/hr.

  7. The Development of a Scanning Soft X-Ray Microscope.

    NASA Astrophysics Data System (ADS)

    Rarback, Harvey Miles

    We have developed a scanning soft X-ray microscope, which can be used to image natural biological specimens at high resolution and with less damage than electron microscopy. The microscope focuses a monochromatic beam of synchrotron radiation to a nearly diffraction limited spot with the aid of a high resolution Fresnel zone plate, specially fabricated for us at the IBM Watson Research Center. The specimen at one atmosphere is mechanically scanned through the spot and the transmitted radiation is efficiently detected with a flow proportional counter. A computer forms a realtime transmission image of the specimen which is displayed on a color monitor. Our first generation optics have produced images of natural wet specimens at a resolution of 300 nm.

  8. SPACE DOSIMETRY MEASUREMENTS IN THE STRATOSPHERE USING DIFFERENT ACTIVE AND PASSIVE DOSIMETRY SYSTEMS.

    PubMed

    Zábori, Balázs; Hirn, Attila; Deme, Sándor; Apáthy, István; Csőke, Antal; Pázmándi, Tamás; Szántó, Péter

    2016-12-01

    Several measurements have been performed on the cosmic radiation field from the surface of the Earth up to the maximum altitudes of research aeroplanes. However, there is only limited information about that between 15 and 30 km altitudes. In order to study the radiation environment in the stratosphere, an experiment was built by students from Hungarian universities that flew on board the BEXUS (Balloon Experiments for University Students) stratospheric balloon in Northern Sweden, from the ESRANGE Space Center. The main technical goals of the experiment were to test at the first time the TRITEL 3D silicon detector telescope system in close to space conditions and to develop a balloon technology platform for advanced cosmic radiation and dosimetric measurements. The main scientific goals were to give an assessment of the cosmic radiation field at the altitude of the BEXUS balloons, to use the TRITEL system to determine dosimetric and radiation quantities during the balloon flight and to intercompare the TRITEL and Pille results to provide a correction factor for the Pille measurements. To fulfil the scientific and technological objectives, several different dosimeter systems were included in the experiment: an advanced version of the TRITEL silicon detector telescope, Geiger-Müller (GM) counters and Pille thermoluminescent dosimeters. The float altitude of the BEXUS balloon was ∼28.6 km; the total flight time was ∼4 h. Measurement data from the active instruments were received in real time by the ground team during the mission. There were no failures in the operation of the system; everything worked as expected. This article presents the scientific goals and results in detail. From the TRITEL measurements, the linear energy transfer spectra, the average quality factor of the cosmic radiation as well as the absorbed dose and the dose equivalent were determined. Estimations for the uncertainty in the TRITEL measurements were given. The deposited energy spectra measured with the TRITEL instrument were compared with the count rates measured with the GM counters. The experiences and results gained in the frame of the project will be used in the evaluation of TRITEL data from measurements on board the International Space Station. As an outlook a short overview is given of the planned rocket radiation experiments based on the system used in the BEXUS programme. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Space Radiation Organ Doses for Astronauts on Past and Future Missions

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.

    2007-01-01

    We review methods and data used for determining astronaut organ dose equivalents on past space missions including Apollo, Skylab, Space Shuttle, NASA-Mir, and International Space Station (ISS). Expectations for future lunar missions are also described. Physical measurements of space radiation include the absorbed dose, dose equivalent, and linear energy transfer (LET) spectra, or a related quantity, the lineal energy (y) spectra that is measured by a tissue equivalent proportional counter (TEPC). These data are used in conjunction with space radiation transport models to project organ specific doses used in cancer and other risk projection models. Biodosimetry data from Mir, STS, and ISS missions provide an alternative estimate of organ dose equivalents based on chromosome aberrations. The physical environments inside spacecraft are currently well understood with errors in organ dose projections estimated as less than plus or minus 15%, however understanding the biological risks from space radiation remains a difficult problem because of the many radiation types including protons, heavy ions, and secondary neutrons for which there are no human data to estimate risks. The accuracy of projections of organ dose equivalents described here must be supplemented with research on the health risks of space exposure to properly assess crew safety for exploration missions.

  10. Remote Sensing of Radiation Dose Rate by a Robot for Outdoor Usage

    NASA Astrophysics Data System (ADS)

    Kobayashi, T.; Doi, K.; Kanematsu, H.; Utsumi, Y.; Hashimoto, R.; Takashina, T.

    2013-04-01

    In the present paper, the design and prototyping of a telemetry system, in which GPS, camera, and scintillation counter were mounted on a crawler type traveling vehicle, were conducted for targeting outdoor usage such as school playground. As a result, the crawler type traveling vehicle can be operated smoothly in the school grounds of brick and asphalt. The results were as follows: (1) It was confirmed that the crawler type traveling vehicle can be operated smoothly in the school grounds of brick and asphalt (running speed: 17[m/min]). (2) It was confirmed that the location information captured by GPS is visible on the Google map, and that the incorporation of video information is also possible to play. (3)A radiation dose rate of 0.09[μSv / h] was obtained in the ground. The value is less than the 1/40 ([3.8μSv / h]) allowable radiation dose rate for children in Fukushima Prefecture.(4)As a further work, modifying to program traveling, the measurement of the distribution of the radiation dose rate in a school of Fukushima Prefecture, and class delivery on radiation measurement will be carried out.

  11. Operational radiological support for the US manned space program

    NASA Technical Reports Server (NTRS)

    Golightly, Michael J.; Hardy, Alva C.; Atwell, William; Weyland, Mark D.; Kern, John; Cash, Bernard L.

    1993-01-01

    Radiological support for the manned space program is provided by the Space Radiation Analysis Group at NASA/JSC. This support ensures crew safety through mission design analysis, real-time space environment monitoring, and crew exposure measurements. Preflight crew exposure calculations using mission design information are used to ensure that crew exposures will remain within established limits. During missions, space environment conditions are continuously monitored from within the Mission Control Center. In the event of a radiation environment enhancement, the impact to crew exposure is assessed and recommendations are provided to flight management. Radiation dosimeters are placed throughout the spacecraft and provided to each crewmember. During a radiation contingency, the crew could be requested to provide dosimeter readings. This information would be used for projecting crew dose enhancements. New instrumentation and computer technology are being developed to improve the support. Improved instruments include tissue equivalent proportional counter (TEPC)-based dosimeters and charged particle telescopes. Data from these instruments will be telemetered and will provide flight controllers with unprecedented information regarding the radiation environment in and around the spacecraft. New software is being acquired and developed to provide 'smart' space environmental data displays for use by flight controllers.

  12. Measurements of the linear energy transfer spectra on the Mir orbital station and comparison with radiation transport models

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Konradi, A.; Atwell, W.; Golightly, M. J.; Cucinotta, F. A.; Wilson, J. W.; Petrov, V. M.; Tchernykh, I. V.; Shurshakov, V. A.; Lobakov, A. P.

    1996-01-01

    A tissue equivalent proportional counter designed to measure the linear energy transfer spectra (LET) in the range 0.2-1250 keV/micrometer was flown in the Kvant module on the Mir orbital station during September 1994. The spacecraft was in a 51.65 degrees inclination, elliptical (390 x 402 km) orbit. This is nearly the lower limit of its flight altitude. The total absorbed dose rate measured was 411.3 +/- 4.41 microGy/day with an average quality factor of 2.44. The galactic cosmic radiation (GCR) dose rate was 133.6 microGy/day with a quality factor of 3.35. The trapped radiation belt dose rate was 277.7 microGy/day with an average quality factor of 1.94. The peak rate through the South Atlantic Anomaly was approximately 12 microGy/min and nearly constant from one pass to another. A detailed comparison of the measured LET spectra has been made with radiation transport models. The GCR results are in good agreement with model calculations; however, this is not the case for radiation belt particles and again points to the need for improving the AP8 omni-directional trapped proton models.

  13. Influence of various factors on individual radiation exposure from the Chernobyl disaster.

    PubMed

    Zamostian, Pavlo; Moysich, Kirsten B; Mahoney, Martin C; McCarthy, Philip; Bondar, Alexandra; Noschenko, Andrey G; Michalek, Arthur M

    2002-10-29

    The explosion at the Chernobyl Nuclear Power Plant was one of the greatest known nuclear disasters of the 20th century. To reduce individual exposure to ionizing radiation the Soviet Union government introduced a number of counter-measures. This article presents a description of how historical events conspired to disrupt these efforts and affect residents in exposed areas. This study employed an extensive review of data on radionuclide deposition, contamination patterns and lifestyle characteristics. Data were obtained from the Ukraine Ministry of Health and the Ukraine Research Center for Radiation Medicine. Data are presented on annual contamination rates in selected locales as well as data on local food consumption patterns. Historical factors including economic and political circumstances are also highlighted. Results show the diminution of individual doses between 1987 and 1991 and then an increase between 1991 and 1994 and the relationship between this increase and changes in the lifestyle of the local population. A number of factors played direct and indirect roles in contributing to the populace's cumulative radiation exposure. Future post-contamination studies need to consider these factors when estimating individual exposures.

  14. Remote inspection with multi-copters, radiological sensors and SLAM techniques

    NASA Astrophysics Data System (ADS)

    Carvalho, Henrique; Vale, Alberto; Marques, Rúben; Ventura, Rodrigo; Brouwer, Yoeri; Gonçalves, Bruno

    2018-01-01

    Activated material can be found in different scenarios, such as in nuclear reactor facilities or medical facilities (e.g. in positron emission tomography commonly known as PET scanning). In addition, there are unexpected scenarios resulting from possible accidents, or where dangerous material is hidden for terrorism attacks using nuclear weapons. Thus, a technological solution is important to cope with fast and reliable remote inspection. The multi-copter is a common type of Unmanned Aerial Vehicle (UAV) that provides the ability to perform a first radiological inspection in the described scenarios. The paper proposes a solution with a multi-copter equipped with on-board sensors to perform a 3D reconstruction and a radiological mapping of the scenario. A depth camera and a Geiger-Müler counter are the used sensors. The inspection is performed in two steps: i) a 3D reconstruction of the environment and ii) radiation activity inference to localise and quantify sources of radiation. Experimental results were achieved with real 3D data and simulated radiation activity. Experimental tests with real sources of radiation are planned in the next iteration of the work.

  15. Radiation biodosimetry: Applications for spaceflight

    NASA Astrophysics Data System (ADS)

    Blakely, W. F.; Miller, A. C.; Grace, M. B.; McLeland, C. B.; Luo, L.; Muderhwa, J. M.; Miner, V. L.; Prasanna, P. G. S.

    The multiparametric dosimetry system that we are developing for medical radiological defense applications could be adapted for spaceflight environments. The system complements the internationally accepted personnel dosimeters and cytogenetic analysis of chromosome aberrations, considered the best means of documenting radiation doses for health records. Our system consists of a portable hematology analyzer, molecular biodosimetry using nucleic acid and antigen-based diagnostic equipment, and a dose assessment management software application. A dry-capillary tube reagent-based centrifuge blood cell counter (QBC Autoread Plus, Beckon Dickinson Bioscience) measures peripheral blood lymphocytes and monocytes, which could determine radiation dose based on the kinetics of blood cell depletion. Molecular biomarkers for ionizing radiation exposure (gene expression changes, blood proteins) can be measured in real time using such diagnostic detection technologies as miniaturized nucleic acid sequences and antigen-based biosensors, but they require validation of dose-dependent targets and development of optimized protocols and analysis systems. The Biodosimetry Assessment Tool, a software application, calculates radiation dose based on a patient's physical signs and symptoms and blood cell count analysis. It also annotates location of personnel dosimeters, displays a summary of a patient's dosimetric information to healthcare professionals, and archives the data for further use. These radiation assessment diagnostic technologies can have dual-use applications supporting general medical-related care.

  16. Topological lattice using multi-frequency radiation

    NASA Astrophysics Data System (ADS)

    Andrijauskas, Tomas; Spielman, I. B.; Juzeliūnas, Gediminas

    2018-05-01

    We describe a novel technique for creating an artificial magnetic field for ultracold atoms using a periodically pulsed pair of counter propagating Raman lasers that drive transitions between a pair of internal atomic spin states: a multi-frequency coupling term. In conjunction with a magnetic field gradient, this dynamically generates a rectangular lattice with a non-staggered magnetic flux. For a wide range of parameters, the resulting Bloch bands have non-trivial topology, reminiscent of Landau levels, as quantified by their Chern numbers.

  17. The Remote Detection of Alpha-Radioactive Nucleus Decay

    NASA Astrophysics Data System (ADS)

    Gurkovskiy, Boris; Miroshnichenko, Vladimir; Onishchenko, Evgeny; Simakov, Andrey; Streil, Thomas

    Results of the new device design for the alpha-radiation remote detection are presented. Negative ions from the alpha particle tracks are detected by the discharge wire counter opened to air. Ion clusters being transferred from the particle tracks to the detector volume by an air flux. The detector works in a counting mode that provides sharp selectivity and accuracy of measurements. The basic parameters of the device are: detecting distance -0.5 m; measurement time -30 s; the square sensitivity -0.05 Bq/cm2.

  18. RRTMGP: A High-Performance Broadband Radiation Code for the Next Decade

    DTIC Science & Technology

    2014-09-30

    Hardware counters were used to measure several performance metrics, including the number of double-precision (DP) floating- point operations ( FLOPs ...0.2 DP FLOPs per CPU cycle. Experience with production science code is that it is possible to achieve execution rates in the range of 0.5 to 1.0...DP FLOPs per cycle. Looking at the ratio of vectorized DP FLOPs to total DP FLOPs we see (Figure PROF) that for most of the execution time the

  19. Accomplishments of the Oak Ridge National Laboratory Seed Money program

    DOE R&D Accomplishments Database

    1986-09-01

    In 1974, a modest program for funding new, innovative research was initiated at ORNL. It was called the "Seed Money" program and has become part of a larger program, called Exploratory R and D, which is being carried out at all DOE national laboratories. This report highlights 12 accomplishments of the Seed Money Program: nickel aluminide, ion implantation, laser annealing, burn meter, Legionnaires' disease, whole-body radiation counter, the ANFLOW system, genetics and molecular biology, high-voltage equipment, microcalorimeter, positron probe, and atom science. (DLC)

  20. Use of Very Weak Radiation Sources to Determine Aircraft Runway Position

    NASA Technical Reports Server (NTRS)

    Drinkwater, Fred J., III; Kibort, Bernard R.

    1965-01-01

    Various methods of providing runway information in the cockpit during the take-off and landing roll have been proposed. The most reliable method has been to use runway distance markers when visible. Flight tests were used to evaluate the feasibility of using weak radio-active sources to trigger a runway distance counter in the cockpit. The results of these tests indicate that a weak radioactive source would provide a reliable signal by which this indicator could be operated.

  1. RADIATION-MEASURING SYSTEMS OF SOVIET ROCKETS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vakulov, P.V.; Goryunov, N.N.; Logachev, Yu.I.

    1961-11-01

    The second and third Sputniks and all Soviet space rockets and spaceship- satellites were equipped with radiationmeasuring systems comprising scintillation and gasdischarge counters and shaping, amplification, and scaling circuits. The scintillation counters use photomultipliers having either 40 x 40 Nal(Tl) or 20 x 20 Csl(Tl) cylindrical crystals. Both types have a gain of ~5.10/sup 4/. The highvoltage battery supplies voltages to the photomultipliers without the use of voltage dividers. Pulses from the 11th, 9th, and 8th dynodes are used for counting the number of particles which produce energy yields from the crystal exceeding ~50 and 500 kev and 5 Mev,more » respectively. Fourstage transistor amplifiers with an over-all gain of ~100 are used for amplification of the counting pulses. The trigger-discriminator, together with the amplifier, is capable of counting (2.5 -- 3.0) x 10/sup 5/ pulses/sec and of insuring a threshold stability of 10% at ambient temperatures of --30 to +50 deg C and voltage variations of plus or minus 20%. Ionization is measured from the current of the 7th dynode and the photomultiplier collector, which permits readings as low as 10/sup -10/ amp to be made by the method of charge storage (in the capacitor) with subsequent discharge through a neon tube. A gas-disoharge counter with 50 mg/cm/sup 2/ stainless-steel walls, operating at 400 v, also measures ionization. Before coming to the scaling circuit, the 50 v negative pulses from this counter pass through a transistor amplifier which changes their polarity and reduces their duration to 8 to 10 mu sec. (OTS)« less

  2. Dual-Chamber/Dual-Anode Proportional Counter Incorporating an Intervening Thin-Foil Solid Neutron Converter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boatner, Lynn A; Neal, John S; Blackston, Matthew A

    2012-01-01

    A dual-chamber/dual-anode gas proportional counter utilizing thin solid 6LiF or 10B neutron converters coated on a 2-micon-thick Mylar film that is positioned between the two counter chambers and anodes has been designed, fabricated, and tested using a variety of fill gases including naturally abundant helium. In this device, neutron conversion products emitted from both sides of the coated converter foil are detected rather than having half of the products absorbed in the wall of a conventional tube type counter where the solid neutron converter is deposited on the tube wall. Geant4-based radiation transport calculations were used to determine the optimummore » neutron converter coating thickness for both isotopes. Solution methods for applying these optimized-thickness coatings on a Mylar film were developed that were carried out at room temperature without any specialized equipment and that can be adapted to standard coating methods such as silk screen or ink jet printing. The performance characteristics of the dual-chamber/dual-anode neutron detector were determined for both types of isotopically enriched converters. The experimental performance of the 6LiF converter-based detector was described well by modeling results from Geant4. Additional modeling studies of multiple-foil/multiple-chamber/anode configurations addressed the basic issue of the relatively longer absorption range of neutrons versus the shorter range of the conversion products for 6LiF and 10B. Combined with the experimental results, these simulations indicate that a high-performance neutron detector can be realized in a single device through the application of these multiple-foil/solid converter, multiple-chamber detector concepts.« less

  3. Construction of 144, 565 keV and 5.0 MeV monoenergetic neutron calibration fields at JAERI.

    PubMed

    Tanimura, Y; Yoshizawa, M; Saegusa, J; Fujii, K; Shimizu, S; Yoshida, M; Shibata, Y; Uritani, A; Kudo, K

    2004-01-01

    Monoenergetic neutron calibration fields of 144, 565 keV and 5.0 MeV have been developed at the Facility of Radiation Standards of JAERI using a 4 MV Pelletron accelerator. The 7Li(p,n)7Be and 2H(d,n)3He reactions are employed for neutron production. The neutron energy was measured by the time-of-flight method with a liquid scintillation detector and calculated with the MCNP-ANT code. A long counter is employed as a neutron monitor because of the flat response. The monitor is set up where the influence of inscattered neutrons from devices and their supporting materials at a calibration point is as small as possible. The calibration coefficients from the monitor counts to the neutron fluence at a calibration point were obtained from the reference fluence measured with the transfer instrument of the primary standard laboratory (AIST), a 24.13 cm phi Bonner sphere counter. The traceability of the fields to AIST was established through the calibration.

  4. Precipitation and Hydrology Experiment Counter-Flow Spectrometer and Impactor Field Campaign Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poellot, Michael

    The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Aerial Facility (ARM AAF) counter-flow spectrometer and impactor (CSI) probe was flown on the University of North Dakota Cessna Citation research aircraft during the Integrated Precipitation and Hydrology Experiment (IPHEX). The field campaign took place during May and June of 2014 over North Carolina and its coastal waters as part of a National Aeronautics and Space Administration (NASA) Global Precipitation Measurement validation campaign. The CSI was added to the Citation instrument suite to support the involvement of Jay Mace through the NASA Advanced Composition Explorer (ACE) satellitemore » program and flights of the NASA ER-2 aircraft, which is a civilian version of the Air Force’s U2-S reconnaissance platform. The ACE program funded extra ER-2 flights to focus on clouds that are weakly precipitating, which are also of interest to the Atmospheric System Research program sponsored by DOE.« less

  5. MCNP modelling of the wall effects observed in tissue-equivalent proportional counters.

    PubMed

    Hoff, J L; Townsend, L W

    2002-01-01

    Tissue-equivalent proportional counters (TEPCs) utilise tissue-equivalent materials to depict homogeneous microscopic volumes of human tissue. Although both the walls and gas simulate the same medium, they respond to radiation differently. Density differences between the two materials cause distortions, or wall effects, in measurements, with the most dominant effect caused by delta rays. This study uses a Monte Carlo transport code, MCNP, to simulate the transport of secondary electrons within a TEPC. The Rudd model, a singly differential cross section with no dependence on electron direction, is used to describe the energy spectrum obtained by the impact of two iron beams on water. Based on the models used in this study, a wall-less TEPC had a higher lineal energy (keV.micron-1) as a function of impact parameter than a solid-wall TEPC for the iron beams under consideration. An important conclusion of this study is that MCNP has the ability to model the wall effects observed in TEPCs.

  6. Analysis of the effects of atomic mass, jet velocity, and radiative cooling on the dimensionless parameters of counter-propagating, weakly collisional plasma flows

    NASA Astrophysics Data System (ADS)

    Collins, Gilbert; Valenzuela, Julio; Beg, Farhat

    2016-10-01

    We have studied the collision of counter-propagating plasma flows using opposing conical wire arrays driven by the 200kA, 150ns rise-time `GenASIS' driver. These plasma flows produced weakly collisional, well-defined bow-shock structures. Varying initial parameters such as the opening angle of the array and the atomic mass of the wires allowed us to modify quantities such as the density contrast between jets, intra-jet mean free path (λmfp, scales with v, atomic mass A, and ionization state Zi-4) , Reynolds number (Re, scales with AZ), and the Peclet number (Pe, scales with Z). We calculate these dimensionless quantities using schlieren imagery, interferometry, and emission data, and determine whether they meet the scaling criteria necessary for the comparison to and subsequent study of astrophysical plasmas. This work was partially supported by the Department of Energy Grant Number DE-SC0014493.

  7. An Experiment in Radiation Measurement Using the Depron Instrument

    NASA Astrophysics Data System (ADS)

    Benghin, Victor V.; Nechaev, Oleg Y.; Zolotarev, Ivan A.; Amelyushkin, Alexander M.; Petrov, Vasiliy L.; Panasyuk, Milhail I.; Yashin, Ivan V.

    2018-02-01

    Most of the radiation measurements have been made onboard spacecraft flying along orbits with an inclination of up to 51.6 degrees. Due to the prospect of manned missions at orbits with larger inclinations, it is advisable to conduct preliminary detailed dosimetry measurements at a high-inclination orbit; due to its polar orbit, the Lomonosov satellite provides good opportunities for such study. We chose a method of cosmic radiation dosimetry based on semiconductor detectors. This method is widely used onboard spacecraft, including full-time radiation monitoring onboard the International Space Station (ISS). It should be noted that not only did the charged particles contribute significantly in the dose equivalent, but also did the neutrons. Semiconductor detectors have low sensitivity to neutron radiation and are not sufficient for detecting the expected flux of neutrons. We add a thermal neutron counter to the proposed device in order to provide an opportunity for estimation of neutron flux variations along the satellite trajectory. Thus, the design of the instrument DEPRON (Dosimeter of Electrons, PROtons and Neutrons) was determined. DEPRON is intended for registration of the absorbed doses and linear energy transfer spectra for high-energy electrons, protons and nuclei of space radiation, as well as registration of thermal neutrons. The present paper provides a brief description of the DEPRON instrument. Its calibration results and the first mission results of background radiation measurements are also presented.

  8. First results of experiments with a medical one-coordinate X-ray detector on synchrotron radiation of VEPP-4

    NASA Astrophysics Data System (ADS)

    Dementyev, E. N.; Dovga, E. Ya.; Kulipanov, G. N.; Medvedko, A. S.; Mezentsev, N. A.; Pindyurin, V. F.; Sheromov, M. A.; Skrinsky, A. N.; Sokolov, A. S.; Ushakov, V. A.; Zagorodnikov, E. I.; Kaidorin, A. G.; Neugodov, Yu. V.

    1986-05-01

    The first results of studying the performance of a fast X-ray one-coordinate detector on the SR beam from VEPP-4 are presented. The detector consists of 128 independent channels, each being a scintillation counter on the basis of NaI(Tl) crystals. The spatial resolution of the detector constitutes 1.5 mm and its speed of response is 128 × 1 MHz. The main purpose of the detector is to examine the human circulatory system by the method of difference angiography at an energy of quanta corresponding to the K-absorption edge of iodine (33.2 keV). The first results on radiation exposure of the blood vessels of a live dog with a spatial resolution of 0.75 mm are given.

  9. TEPC Response Functions

    NASA Technical Reports Server (NTRS)

    Shinn, J. L.; Wilson, J. W.

    2003-01-01

    The tissue equivalent proportional counter had the purpose of providing the energy absorbed from a radiation field and an estimate of the corresponding linear energy transfer (LET) for evaluation of radiation quality to convert to dose equivalent. It was the recognition of the limitations in estimating LET which lead to a new approach to dosimetry, microdosimetry, and the corresponding emphasis on energy deposit in a small tissue volume as the driver of biological response with the defined quantity of lineal energy. In many circumstances, the average of the lineal energy and LET are closely related and has provided a basis for estimating dose equivalent. Still in many cases the lineal is poorly related to LET and brings into question the usefulness as a general purpose device. These relationships are examined in this paper.

  10. Dipeptide Formation from Amino Acid Monomer Induced by keV Ion Irradiation: An Implication for Physicochemical Repair by Radiation Itself

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Yuan, Hang; Wang, Xiangqin; Yu, Zengliang

    2008-02-01

    An identification of Phe dipeptide from L-phenylalanine monomers after keV nitrogen and argon ion implantation, by using the HPLC (high performance liquid chromatography) and LC-MS(liquid chromatography mass spectrometer) methods is reported. The results showed a similar yield behavior for both ion species, namely: 1) the yield of dipeptides under alkalescent conditions was distinctly higher than that under acidic or neutral conditions; 2) for different ion species, the dose-yield curves tracked a similar trend which was called a counter-saddle curve. The dipeptide formation may implicate a recombination repair mechanism of damaged biomolecules that energetic ions have left in their wake. Accordingly a physicochemical self-repair mechanism by radiation itself for the ion-beam radiobiological effects is proposed.

  11. Thermal neutron radiative capture on cadmium as a counting technique at the INES beam line at ISIS: A preliminary investigation of detector cross-talk.

    PubMed

    Festa, G; Grazzi, F; Pietropaolo, A; Scherillo, A; Schooneveld, E M

    2017-12-01

    Experimental tests are presented that assess the cross-talk level among three scintillation detectors used as neutron counters exploiting the thermal neutron radiative capture on Cd. The measurements were done at the INES diffractometer operating at the ISIS spallation neutron source (Rutherford Appleton Laboratory, UK). These tests follow a preliminary set of measurements performed on the same instrument to study the effectiveness of this thermal neutron counting strategy in neutron diffraction measurements, typically performed on INES using squashed 3 He filled gas tubes. The experimental data were collected in two different geometrical configurations of the detectors and compared to results of Monte Carlo simulations, performed using the MCNP code. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. LaCl3:Ce Coincidence Signatures to Calibrate Gamma-ray Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McIntyre, Justin I.; Schrom, Brian T.; Cooper, Matthew W.

    Abstract Calibrating the gamma-ray detection efficiency of radiation detectors in a field environment is difficult under most circumstances. To counter this problem we have developed a technique that uses a Cerium doped Lanthanum-Tri-Chloride (LaCl3:Ce) scintillation detector to provide gated gammas[ , ]. Exploiting the inherent radioactivity of the LaCl3:Ce due to the long-lived radioactive isotope 138La (t1/2 = 1.06 x 1011 yrs) allows the use of the 788 and 1436-keV gammas as a measure of efficiency. In this paper we explore the effectiveness of using the beta-gamma coincidences radiation LaCl3:Ce detector to calibrate the energy and efficiency of a numbermore » of gamma-ray detectors.« less

  13. The Lore of the Hair

    NASA Astrophysics Data System (ADS)

    Yunes, Nicolas; Yagi, Kent; Stein, Leo

    2016-03-01

    Stars can be hairy beasts, especially in theories that go beyond Einstein's. In the latter, a scalar field can be sourced and anchored to a neutron star, and if the later is in a binary system, the scalar field will emit dipole radiation. This radiation removes energy from the binary, forcing the orbit to adiabatically decay much more rapidly than due to the emission of gravitational waves as predicted in General Relativity. The detailed radio observation of binary pulsars has constrained the orbital decay of compact binaries stringently, so much so that theories that predict neutron stars with scalar hair are believed to be essentially ruled out. In this talk I will explain why this ``lore'' is actually incorrect, providing a counter-example in which scalar hair is sourced by neutron stars, yet dipole radiation is absent. I will then describe what binary systems need to be observed to constrain such theories with future astrophysical observations. I acknowledge support from NSF CAREER Grant PHY-1250636.

  14. Nurse exposure doses resulted from bone scintigraphy patient

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tunçman, Duygu, E-mail: duygutuncman@gmail.com; Demir, Bayram; Kovan, Bilal

    Bone scintigraphy is used for displaying the radiologic undiagnosed bone lesions in nuclear medicine. It’s general indications are researching bone metastases, detection of radiographically occult fractures, staging and follow-up in primary bone tumors, diagnosis of paget’s disease, investigation of loosening and infection in orthopedic implants. It is applied with using {sup 99m}Tc labeled radiopharmaceuticals (e.g {sup 99m} Tc MDP,{sup 99m}Tc HEDP and {sup 99m}Tc HMDP). 20 -25 mCi IV radiotracer was injected into vein and radiotracer emits gamma radiation. Patient waits in isolated room for about 3 hours then a gamma camera scans radiation area and creates an image. Whenmore » some patient’s situation is not good, patients are hospitalized until the scanning because of patients’ close contact care need. In this study, measurements were taken from ten patients using Geiger Muller counter. After these measurements, we calculated nurse’s exposure radiations from patient’s routine treatment, examination and emergency station.« less

  15. Calibration Uncertainties in the Droplet Measurement Technologies Cloud Condensation Nuclei Counter

    NASA Astrophysics Data System (ADS)

    Hibert, Kurt James

    Cloud condensation nuclei (CCN) serve as the nucleation sites for the condensation of water vapor in Earth's atmosphere and are important for their effect on climate and weather. The influence of CCN on cloud radiative properties (aerosol indirect effect) is the most uncertain of quantified radiative forcing changes that have occurred since pre-industrial times. CCN influence the weather because intrinsic and extrinsic aerosol properties affect cloud formation and precipitation development. To quantify these effects, it is necessary to accurately measure CCN, which requires accurate calibrations using a consistent methodology. Furthermore, the calibration uncertainties are required to compare measurements from different field projects. CCN uncertainties also aid the integration of CCN measurements with atmospheric models. The commercially available Droplet Measurement Technologies (DMT) CCN Counter is used by many research groups, so it is important to quantify its calibration uncertainty. Uncertainties in the calibration of the DMT CCN counter exist in the flow rate and supersaturation values. The concentration depends on the accuracy of the flow rate calibration, which does not have a large (4.3 %) uncertainty. The supersaturation depends on chamber pressure, temperature, and flow rate. The supersaturation calibration is a complex process since the chamber's supersaturation must be inferred from a temperature difference measurement. Additionally, calibration errors can result from the Kohler theory assumptions, fitting methods utilized, the influence of multiply-charged particles, and calibration points used. In order to determine the calibration uncertainties and the pressure dependence of the supersaturation calibration, three calibrations are done at each pressure level: 700, 840, and 980 hPa. Typically 700 hPa is the pressure used for aircraft measurements in the boundary layer, 840 hPa is the calibration pressure at DMT in Boulder, CO, and 980 hPa is the average surface pressure at Grand Forks, ND. The supersaturation calibration uncertainty is 2.3, 3.1, and 4.4 % for calibrations done at 700, 840, and 980 hPa respectively. The supersaturation calibration change with pressure is on average 0.047 % supersaturation per 100 hPa. The supersaturation calibrations done at UND are 42-45 % lower than supersaturation calibrations done at DMT approximately 1 year previously. Performance checks confirmed that all major leaks developed during shipping were fixed before conducting the supersaturation calibrations. Multiply-charged particles passing through the Electrostatic Classifier may have influenced DMT's activation curves, which is likely part of the supersaturation calibration difference. Furthermore, the fitting method used to calculate the activation size and the limited calibration points are likely significant sources of error in DMT's supersaturation calibration. While the DMT CCN counter's calibration uncertainties are relatively small, and the pressure dependence is easily accounted for, the calibration methodology used by different groups can be very important. The insights gained from the careful calibration of the DMT CCN counter indicate that calibration of scientific instruments using complex methodology is not trivial.

  16. Dynamic modeling of temperature change in outdoor operated tubular photobioreactors.

    PubMed

    Androga, Dominic Deo; Uyar, Basar; Koku, Harun; Eroglu, Inci

    2017-07-01

    In this study, a one-dimensional transient model was developed to analyze the temperature variation of tubular photobioreactors operated outdoors and the validity of the model was tested by comparing the predictions of the model with the experimental data. The model included the effects of convection and radiative heat exchange on the reactor temperature throughout the day. The temperatures in the reactors increased with increasing solar radiation and air temperatures, and the predicted reactor temperatures corresponded well to the measured experimental values. The heat transferred to the reactor was mainly through radiation: the radiative heat absorbed by the reactor medium, ground radiation, air radiation, and solar (direct and diffuse) radiation, while heat loss was mainly through the heat transfer to the cooling water and forced convection. The amount of heat transferred by reflected radiation and metabolic activities of the bacteria and pump work was negligible. Counter-current cooling was more effective in controlling reactor temperature than co-current cooling. The model developed identifies major heat transfer mechanisms in outdoor operated tubular photobioreactors, and accurately predicts temperature changes in these systems. This is useful in determining cooling duty under transient conditions and scaling up photobioreactors. The photobioreactor design and the thermal modeling were carried out and experimental results obtained for the case study of photofermentative hydrogen production by Rhodobacter capsulatus, but the approach is applicable to photobiological systems that are to be operated under outdoor conditions with significant cooling demands.

  17. Radiation Measured with Different Dosimeters for ISS-Expedition 18-19/ULF2 on Board International Space Station during Solar Minimum

    NASA Technical Reports Server (NTRS)

    Zhou, Dazhuang; Gaza, R.; Roed, Y.; Semones, E.; Lee, K.; Steenburgh, R.; Johnson, S.; Flanders, J.; Zapp, N.

    2010-01-01

    Radiation field of particles in low Earth orbit (LEO) is mainly composed of galactic cosmic rays (GCR), solar energetic particles and particles in SAA (South Atlantic Anomaly). GCR are modulated by solar activity, at the period of solar minimum activity, GCR intensity is at maximum and the main contributor for space radiation is GCR. At present for space radiation measurements conducted by JSC (Johnson Space Center) SRAG (Space Radiation Analysis Group), the preferred active dosimeter sensitive to all LET (Linear Energy Transfer) is the tissue equivalent proportional counter (TEPC); the preferred passive dosimeters are thermoluminescence dosimeters (TLDs) and optically stimulated luminescence dosimeters (OSLDs) sensitive to low LET as well as CR-39 plastic nuclear track detectors (PNTDs) sensitive to high LET. For the method using passive dosimeters, radiation quantities for all LET can be obtained by combining radiation results measured with TLDs/OSLDs and CR-39 PNTDs. TEPC, TLDs/OSLDs and CR-39 detectors were used to measure the radiation field for the ISS (International Space Station) - Expedition 18-19/ULF2 space mission which was conducted from 15 November 2008 to 31 July 2009 - near the period of the recent solar minimum activity. LET spectra (differential and integral fluence, absorbed dose and dose equivalent) and radiation quantities were measured for positions TEPC, TESS (Temporary Sleeping Station, inside the polyethylene lined sleep station), SM-P 327 and 442 (Service Module - Panel 327 and 442). This paper presents radiation LET spectra measured with TEPC and CR-39 PNTDs and radiation dose measured with TLDs/OSLDs as well as the radiation quantities combined from results measured with passive dosimeters.

  18. Localized Triple Modular Redundancy vs. Distributed Triple Modular Redundancy on a ProASIC3E Reprogrammable FPGA

    NASA Technical Reports Server (NTRS)

    McGuffey, Alex; Berg, Melanie; Pellish, Jonathan

    2010-01-01

    Field programmable gate arrays (FPGA) are used in every space application. Currently, most space flight applications use radiation hardened (RH) FPGAs, which are very expensive. There is a desire to use cheaper, commercial off the shelf reprogrammable FPGAs, which are more susceptible to radiation effects known as single-event effects (SEE). The RH parts have SEE and total ionizing dose (TID) hardened elements pre-integrated into the part. This means that the designer does not need to implement any hardening techniques while configuring the device. The COTS parts on the other hand must be mitigated by design in order to insure any form of mitigation. The design techniques this project examines concern the use of localized triple modular redundancy (LTMR) and distributed triple modular redundancy (DTMR). LTMR triples every flip flop in the device architecture while DTMR triples everything except for the global routes (clocks, resets, and enables). The testing was performed on a ProASIC3E FPGA at the Texas A&M cyclotron facility. Two design architectures were used: shift registers and counters, both with LTMR and DTMR mitigation techniques. The test results prove that DTMR is more effective at reducing SEE than LTMR. We also determined that there was not a significant difference between the use of shift registers and counters for test purposes. More testing is required to obtain additional linear energy transfer values for each architecture and mitigation technique in order to determine the most cost-effective method of SEE mitigation.

  19. A study of the radiation environment on board the space shuttle flight STS-57

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Atwell, W.; Benton, E. V.; Frank, A. L.; Keegan, R. P.; Dudkin, V. E.; Karpov, O. N.; Potapov, V.; Akopova, A. B.; Magradze, N. V.

    1995-01-01

    A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on space shuttle flight STS-57 was conducted. The shuttle flew in a nearly circular orbit of 28.5 deg inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's), and Russian nuclear emulsions, PNTD's, and TLD's. All the detector systems were shielded by the same shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micron and 200 keV/micron. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than TLD's, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLD's to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

  20. Development and dosimetry of a small animal lung irradiation platform

    PubMed Central

    McGurk, Ross; Hadley, Caroline; Jackson, Isabel L.; Vujaskovic, Zeljko

    2015-01-01

    Advances in large scale screening of medical counter measures for radiation-induced normal tissue toxicity are currently hampered by animal irradiation paradigms that are both inefficient and highly variable among institutions. Here, we introduce a novel high-throughput small animal irradiation platform for use in orthovoltage small animal irradiators. We used radiochromic film and metal oxide semiconductor field effect transistor detectors to examine several parameters, including 2D field uniformity, dose rate consistency, and shielding transmission. We posit that this setup will improve efficiency of drug screens by allowing for simultaneous, targeted irradiation of multiple animals, improving efficiency within a single institution. Additionally, we suggest that measurement of the described parameters in all centers conducting counter measure studies will improve the translatability of findings among institutions. We also investigated the use of tissue equivalent phantoms in performing dosimetry measurements for small animal irradiation experiments. Though these phantoms are commonly used in dosimetry, we recorded a significant difference in both the entrance and target tissue dose rates between euthanized rats and mice with implanted detectors and the corresponding phantom measurement. This suggests that measurements using these phantoms may not provide accurate dosimetry for in vivo experiments. Based on these measurements, we propose that this small animal irradiation platform can increase the capacity of animal studies by allowing for more efficient animal irradiation. We also suggest that researchers fully characterize the parameters of whatever radiation setup is in use in order to facilitate better comparison among institutions. PMID:23091878

  1. Simulated Response of a Tissue-equivalent Proportional Counter on the Surface of Mars.

    PubMed

    Northum, Jeremy D; Guetersloh, Stephen B; Braby, Leslie A; Ford, John R

    2015-10-01

    Uncertainties persist regarding the assessment of the carcinogenic risk associated with galactic cosmic ray (GCR) exposure during a mission to Mars. The GCR spectrum peaks in the range of 300(-1) MeV n to 700 MeV n(-1) and is comprised of elemental ions from H to Ni. While Fe ions represent only 0.03% of the GCR spectrum in terms of particle abundance, they are responsible for nearly 30% of the dose equivalent in free space. Because of this, radiation biology studies focusing on understanding the biological effects of GCR exposure generally use Fe ions. Acting as a thin shield, the Martian atmosphere alters the GCR spectrum in a manner that significantly reduces the importance of Fe ions. Additionally, albedo particles emanating from the regolith complicate the radiation environment. The present study uses the Monte Carlo code FLUKA to simulate the response of a tissue-equivalent proportional counter on the surface of Mars to produce dosimetry quantities and microdosimetry distributions. The dose equivalent rate on the surface of Mars was found to be 0.18 Sv y(-1) with an average quality factor of 2.9 and a dose mean lineal energy of 18.4 keV μm(-1). Additionally, albedo neutrons were found to account for 25% of the dose equivalent. It is anticipated that these data will provide relevant starting points for use in future risk assessment and mission planning studies.

  2. Experimental Observations on a Low Strain Counter-Flow Diffusion Flame: Flow and Bouyancy Effects

    NASA Technical Reports Server (NTRS)

    Sutula, J. A.; Torero, J. L.; Ezekoye, O. A.

    1999-01-01

    Diffusion flames are of great interest in fire safety and many industrial processes. The counter-flow configuration provides a constant strain flow, and therefore is ideal to study the structure of diffusion flames. Most studies have concentrated on the high velocity, high strain limit, since buoyantly induced instabilities will disintegrate the planar flame as the velocity decreases. Only recently, experimental studies in microgravity conditions have begun to explore the low strain regimes. Numerical work has shown the coupling between gas phase reaction rates, soot reaction rates, and radiation. For these programs, size, geometry and experimental conditions have been chosen to keep the flame unaffected by the physical boundaries. When the physical boundaries can not be considered infinitely far from the reaction zone discrepancies arise. A computational study that includes boundary effects and accounts for the deviations occurring when the major potential flow assumptions are relaxed was presented by Borlik et al. This development properly incorporates all heat loss terms and shows the possibility of extinction in the low strain regime. A major constraint of studying the low strain regime is buoyancy. Buoyant instabilities have been shown to have a significant effect on the nature of reactants and heat transport, and can introduce instabilities on the flow that result in phenomena such as flickering or fingering. The counter-flow configuration has been shown to provide a flame with no symmetry disrupting instabilities for inlet velocities greater than 50 mm/s. As the velocity approaches this limit, the characteristic length of the experiment has to be reduced to a few millimetres so as to keep the Rayleigh number (Ra(sub L) = (Beta)(g(sub 0))(L(exp 3) del T)/(alpha(v))) below 2000. In this work, a rectangular counter-flow burner was used to study a two-dimensional counter-flow diffusion flame. Flow visualisation and Particle Image Velocimetry served to describe the nature of the stagnation plane for strain rates smaller than 100 (1/s). These experiments were conducted with a non-reacting flow. Video images of a propane air diffusion flame were used to describe the behaviour of a diffusion flame in this regime. Flame geometry and pulsation frequency are described.

  3. System for Manipulating Drops and Bubbles Using Acoustic Radiation Pressure

    NASA Technical Reports Server (NTRS)

    Oeftering, Richard C. (Inventor)

    1999-01-01

    The manipulation and control of drops of liquid and gas bubbles is achieved using high intensity acoustics in the form of and/or acoustic radiation pressure and acoustic streaming. generated by a controlled wave emission from a transducer. Acoustic radiation pressure is used to deploy or dispense drops into a liquid or a gas or bubbles into a liquid at zero or near zero velocity from the discharge end of a needle such as a syringe needle. Acoustic streaming is useful in manipulating the drop or bubble during or after deployment. Deployment and discharge is achieved by focusing the acoustic radiation pressure on the discharge end of the needle, and passing the acoustic waves through the fluid in the needle. through the needle will itself, or coaxially through the fluid medium surrounding the needle. Alternatively, the acoustic waves can be counter-deployed by focusing on the discharge end of the needle from a transducer axially aligned with the needle, but at a position opposite the needle, to prevent premature deployment of the drop or bubble. The acoustic radiation pressure can also be used for detecting the presence or absence of a drop or a bubble at the tip of a needle or for sensing various physical characteristics of the drop or bubble such as size or density.

  4. A Hypothesis on Biological Protection from Space Radiation Through the Use of New Therapeutic Gases as Medical Counter Measures

    NASA Technical Reports Server (NTRS)

    Schoenfeld, Michael P.; Ansari, Rafat R.; Nakao, Atsunori; Wink, David

    2012-01-01

    Radiation exposure to astronauts could be a significant obstacle for long duration manned space exploration because of current uncertainties regarding the extent of biological effects. Furthermore, concepts for protective shielding also pose a technically challenging issue due to the nature of cosmic radiation and current mass and power constraints with modern exploration technology. The concern regarding exposure to cosmic radiation is the biological damage it induces. As damage is associated with increased oxidative stress, it is important and would be enabling to mitigate and/or prevent oxidative stress prior to the development of clinical symptoms and disease. This paper hypothesizes a "systems biology" approach in which a combination of chemical and biological mitigation techniques are used conjunctively. It proposes using new, therapeutic, medical gases as both chemical radioprotectors for radical scavenging and biological signaling molecules for management of the body s response to exposure. From reviewing radiochemistry of water, biological effects of CO, H2, NO, and H2S gas, and mechanisms of radiation biology, it is concluded that this approach may have great therapeutic potential for radiation exposure. Furthermore, it also appears to have similar potential for curtailing the pathogenesis of other diseases in which oxidative stress has been implicated including cardiovascular disease, cancer, chronic inflammatory disease, hypertension, ischemia/reperfusion injury, acute respiratory distress syndrome, Parkinson s and Alzheimer s disease, cataracts, and aging.

  5. NEUDOSE: A CubeSat Mission for Dosimetry of Charged Particles and Neutrons in Low-Earth Orbit.

    PubMed

    Hanu, A R; Barberiz, J; Bonneville, D; Byun, S H; Chen, L; Ciambella, C; Dao, E; Deshpande, V; Garnett, R; Hunter, S D; Jhirad, A; Johnston, E M; Kordic, M; Kurnell, M; Lopera, L; McFadden, M; Melnichuk, A; Nguyen, J; Otto, A; Scott, R; Wagner, D L; Wiendels, M

    2017-01-01

    During space missions, astronauts are exposed to a stream of energetic and highly ionizing radiation particles that can suppress immune system function, increase cancer risks and even induce acute radiation syndrome if the exposure is large enough. As human exploration goals shift from missions in low-Earth orbit (LEO) to long-duration interplanetary missions, radiation protection remains one of the key technological issues that must be resolved. In this work, we introduce the NEUtron DOSimetry & Exploration (NEUDOSE) CubeSat mission, which will provide new measurements of dose and space radiation quality factors to improve the accuracy of cancer risk projections for current and future space missions. The primary objective of the NEUDOSE CubeSat is to map the in situ lineal energy spectra produced by charged particles and neutrons in LEO where most of the preparatory activities for future interplanetary missions are currently taking place. To perform these measurements, the NEUDOSE CubeSat is equipped with the Charged & Neutral Particle Tissue Equivalent Proportional Counter (CNP-TEPC), an advanced radiation monitoring instrument that uses active coincidence techniques to separate the interactions of charged particles and neutrons in real time. The NEUDOSE CubeSat, currently under development at McMaster University, provides a modern approach to test the CNP-TEPC instrument directly in the unique environment of outer space while simultaneously collecting new georeferenced lineal energy spectra of the radiation environment in LEO.

  6. Lead, platinum, and other heavy elements in the primary cosmic radiation: HEAO-3 results ssc wg032961 cb553097

    NASA Technical Reports Server (NTRS)

    Waddington, C. J.; Binns, W. R.; Brewster, N. R.; Fixsen, D. J.; Garrard, T. L.; Israel, M. H.; Klarmann, J.; Newport, B. J.; Stone, E. C.

    1985-01-01

    An observation of the abundances of cosmic-ray lead and platinum-group nuclei using data from the HEAO-3 Heavy Nuclei Experiment (HNE) which consisted of ion chambers mounted on both sides of a plastic Cerenkov counter is reported. Further analysis with more stringent selections, inclusion of additional data, and a calibration at the LBL Bevalac, have allowed obtaining the abundance ratio of lead and the platinum group of elements for particles that had a cutoff rigidity R sub c 5 GV.

  7. Electrochromic device containing metal oxide nanoparticles and ultraviolet blocking material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garcia, Guillermo; Koo, Bonil; Gregoratto, Ivano

    An electrochromic device includes a nanostructured transition metal oxide bronze layer that includes one or more transition metal oxide and one or more dopant. The electrochromic device also includes nanoparticles containing one or more transparent conducting oxide (TCO), a solid state electrolyte, a counter electrode, and at least one protective layer to prevent degradation of the one or more nanostructured transition metal oxide bronze. The nanostructured transition metal oxide bronze selectively modulates transmittance of near-infrared (NIR) and visible radiation as a function of an applied voltage to the device.

  8. A bioassay experience and lessons learned on the internal contamination of (131)I during a maintenance period in a Korean nuclear power plant.

    PubMed

    Kim, Hee Geun; Kong, Tae Young

    2012-08-01

    During a maintenance period at a Korean nuclear power plant, internal exposure of radiation workers occurred by the inhalation of (131)I that was released into the reactor building from a primary system opening due to defective fuels. The internal activity in radiation workers contaminated by (131)I was immediately measured using a whole body counter (WBC). A whole body counting was performed again a few days later, considering the factors of equilibrium in the body. The intake and the committed effective dose were estimated based on the WBC results. The intake was also calculated by hand, based on both the entrance records to the reactor building, and the counted results of the air concentration for (131)I were compared with the whole body counting results.

  9. High-gain thompson-scattering X-ray free-electron laser by time-synchronic laterally tilted optical wave

    DOEpatents

    Chang, Chao; Tang, Chuanxiang; Wu, Juhao

    2017-05-09

    An improved optical undulator for use in connection with free electron radiation sources is provided. A tilt is introduced between phase fronts of an optical pulse and the pulse front. Two such pulses in a counter-propagating geometry overlap to create a standing wave pattern. A line focus is used to increase the intensity of this standing wave pattern. An electron beam is aligned with the line focus. The relative angle between pulse front and phase fronts is adjusted such that there is a velocity match between the electron beam and the overlapping optical pulses along the line focus. This allows one to provide a long interaction length using short and intense optical pulses, thereby greatly increasing the radiation output from the electron beam as it passes through this optical undulator.

  10. Biologics as countermeasures for acute radiation syndrome: where are we now?

    PubMed

    Singh, Vijay K; Romaine, Patricia L P; Newman, Victoria L

    2015-04-01

    Despite significant scientific advances toward the development of a safe, nontoxic and effective radiation countermeasure for acute radiation syndrome (ARS) over the past six decades, no drug has been approved by the US FDA. Several biologics are currently under development as radiation countermeasures for ARS, of which three have received FDA Investigational New Drug (IND) status for clinical investigation. Presently, two of these agents, entolimod (CBLB502) and HemaMax (recombinant human IL-12) are progressing with large animal studies and clinical trials. Neupogen (G-CSF, filgrastim) has recently been recommended for approval by an FDA Advisory Committee. Filgrastim, GM-CSF (Leukine, sargramostim), and PEGylated G-CSF (Neulasta) have high potential and well-documented therapeutic effects in countering myelosuppression and may receive full licensing approval by the FDA in the future. The former two biologics are available in the US Strategic National Stockpile (SNS) for use in the event of nuclear or radiological emergency. The Emergency Use Authorization (EAU) application for entolimod may be filed soon with the FDA. Biologics are attractive agents that are progressing along the path for FDA approval, to fill the unmet need for ARS countermeasures.

  11. Influence of various factors on individual radiation exposure from the chernobyl disaster

    PubMed Central

    Zamostian, Pavlo; Moysich, Kirsten B; Mahoney, Martin C; McCarthy, Philip; Bondar, Alexandra; Noschenko, Andrey G; Michalek, Arthur M

    2002-01-01

    Background The explosion at the Chernobyl Nuclear Power Plant was one of the greatest known nuclear disasters of the 20th century. To reduce individual exposure to ionizing radiation the Soviet Union government introduced a number of counter-measures. This article presents a description of how historical events conspired to disrupt these efforts and affect residents in exposed areas. Methods This study employed an extensive review of data on radionuclide deposition, contamination patterns and lifestyle characteristics. Data were obtained from the Ukraine Ministry of Health and the Ukraine Research Center for Radiation Medicine. Results Data are presented on annual contamination rates in selected locales as well as data on local food consumption patterns. Historical factors including economic and political circumstances are also highlighted. Results show the diminution of individual doses between 1987 and 1991 and then an increase between 1991 and 1994 and the relationship between this increase and changes in the lifestyle of the local population. Conclusion A number of factors played direct and indirect roles in contributing to the populace's cumulative radiation exposure. Future post-contamination studies need to consider these factors when estimating individual exposures. PMID:12495449

  12. Natural Hazards of the Space Environment

    NASA Technical Reports Server (NTRS)

    Evans, Steven W.; Kross, Dennis A. (Technical Monitor)

    2000-01-01

    Spacecraft in Low Earth Orbit (LEO) are subject to numerous environmental hazards. Here I'll briefly discuss three environment factors that pose acute threats to the survival of spacecraft systems and crew: atmospheric drag, impacts by meteoroids and orbital debris, and ionizing radiation. Atmospheric drag continuously opposes the orbital motion of a satellite, causing the orbit to decay. This decay will lead to reentry if not countered by reboost maneuvers. Orbital debris is a by-product of man's activities in space, and consists of objects ranging in size from miniscule paint chips to spent rocket stages and dead satellites. Ionizing radiation experienced in LEO has several components: geomagnetically trapped protons and electrons (Van Allen belts); energetic solar particles; galactic cosmic rays; and albedo neutrons. These particles can have several types of prompt harmful effects on equipment and crew, from single-event upsets, latchup, and burnout of electronics, to lethal doses to crew.All three types of prompt threat show some dependence on the solar activity cycle. Atmospheric drag mitigation and large debris avoidance require propulsive maneuvers. M/OD and ionizing radiation require some form of shielding for crew and sensitive equipment. Limiting exposure time is a mitigation technique for ionizing radiation and meteor streams.

  13. Space and power efficient hybrid counters array

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2009-05-12

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  14. Space and power efficient hybrid counters array

    DOEpatents

    Gara, Alan G.; Salapura, Valentina

    2010-03-30

    A hybrid counter array device for counting events. The hybrid counter array includes a first counter portion comprising N counter devices, each counter device for receiving signals representing occurrences of events from an event source and providing a first count value corresponding to a lower order bits of the hybrid counter array. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits of the hybrid counter array. A control device monitors each of the N counter devices of the first counter portion and initiates updating a value of a corresponding second count value stored at the corresponding addressable memory location in the second counter portion. Thus, a combination of the first and second count values provide an instantaneous measure of number of events received.

  15. Thallium halide radiation detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ijaz-ur-Rahman; Hofstadter, R.

    1984-03-15

    During a series of experiments on crystal conduction counters performed at Stanford University on thallium halide crystals, we have observed motion of both hole and electron carriers in a TlBr crystal. At a temperature near -90 /sup 0/C the hole motion produces larger pulses than electron motion. We have studied the behavior of TlBr, TlCl, and KRS-5 (40 mol % TlBr + 60 mol % TlI) crystals and examined them as possible crystal conduction detectors of ..cap alpha.. particles and ..gamma.. rays. TlBr appears to be a promising candidate for applications to nuclear physics and high-energy ..gamma..-ray physics. Modules ofmore » TlBr in ''crystal-ball'' geometry may lead to new detection possibilities. At -20 /sup 0/C space-charge accumulation in TlBr decreases to such an extent that operation at this temperature seems possible with moderate electrical gradients. In the long-neglected field of crystal conduction counters, we have potentially removed the space-charge limitation in TlBr and, allowing for both hole and electron motion, raised the possibility for spectroscopic performance of this material for ..gamma..-ray studies.« less

  16. Dense GeV electron–positron pairs generated by lasers in near-critical-density plasmas

    PubMed Central

    Zhu, Xing-Long; Yu, Tong-Pu; Sheng, Zheng-Ming; Yin, Yan; Turcu, Ion Cristian Edmond; Pukhov, Alexander

    2016-01-01

    Pair production can be triggered by high-intensity lasers via the Breit–Wheeler process. However, the straightforward laser–laser colliding for copious numbers of pair creation requires light intensities several orders of magnitude higher than possible with the ongoing laser facilities. Despite the numerous proposed approaches, creating high-energy-density pair plasmas in laboratories is still challenging. Here we present an all-optical scheme for overdense pair production by two counter-propagating lasers irradiating near-critical-density plasmas at only ∼1022 W cm−2. In this scheme, bright γ-rays are generated by radiation-trapped electrons oscillating in the laser fields. The dense γ-photons then collide with the focused counter-propagating lasers to initiate the multi-photon Breit–Wheeler process. Particle-in-cell simulations indicate that one may generate a high-yield (1.05 × 1011) overdense (4 × 1022 cm−3) GeV positron beam using 10 PW scale lasers. Such a bright pair source has many practical applications and could be basis for future compact high-luminosity electron–positron colliders. PMID:27966530

  17. Crystallization and preliminary X-ray diffraction study of phosphoribosyl pyrophosphate synthetase from E. Coli

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timofeev, V. I., E-mail: inna@ns.crys.ras.ru; Abramchik, Yu. A., E-mail: tostars@mail.ru; Zhukhlistova, N. E., E-mail: ugama@yandex.ru

    2015-09-15

    Enzymes of the phosphoribosyl pyrophosphate synthetase family (PRPPS, EC 2.7.6.1) catalyze the formation of 5-phosphoribosyl pyrophosphate (5-PRPP) from adenosine triphosphate and ribose 5-phosphate. 5-Phosphoribosyl pyrophosphate is an important intermediate in the synthesis of purine, pyrimidine, and pyridine nucleotides, as well as of the amino acids histidine and tryptophan. The crystallization conditions for E. coli PRPPS were found by the vapor-diffusion technique and were optimized to apply the capillary counter-diffusion technique. The X-ray diffraction data set was collected from the crystals grown by the counter-diffusion technique using a synchrotron radiation source to 3.1-Å resolution. The crystals of PRPPS belong to sp.more » gr. P6{sub 3}22 and have the following unit-cell parameters: a = b = 104.44 Å, c = 124.98 Å, α = β = 90°, γ = 120°. The collected X-ray diffraction data set is suitable for the solution of the three-dimensional structure of PRPPS at 3.1-Å resolution.« less

  18. Study of the effect of collisionality and cooling on the interactions of counter-streaming plasma flows as a function of wire material

    NASA Astrophysics Data System (ADS)

    Collins, Gilbert; Valenzuela, Julio; Aybar, Nicholas; Conti, Fabio; Beg, Farhat

    2017-10-01

    We report on the effects wire material on collisionality and radiative cooling on the interactions of counter-streaming plasma jets produced by conical wire arrays on the 200 kA GenASIS driver. In these interactions, mean free path (λmfp) scales with jet velocity (vjet4),atomic mass (A2), and ionization (Z*-4), while cooling scales with atomic mass. By changing the material of the jets one can create slowly cooling, weakly collisional regimes using C, Al, or Cu, or strongly cooled, effectively collisionless plasmas using Mo or W. The former produced smooth shocks soon after the jets collide (near the peak current of 150 ns) that grew in size over time. Interactions of the latter produced multiple structures of a different shape, at a later time ( 300 ns) that dissipated rapidly compared to the lower Z materials. We will report on the scaleability of these different materials to astrophysical phenomena. This work was partially supported by the Department of Energy Grant Number DE-SC0014493.

  19. Numerical investigation of biogas diffusion flames characteristics under several operation conditions in counter-flow configuration with an emphasis on thermal and chemical effects of CO2 in the fuel mixture

    NASA Astrophysics Data System (ADS)

    Mameri, A.; Tabet, F.; Hadef, A.

    2017-08-01

    This study addresses the influence of several operating conditions (composition and ambient pressure) on biogas diffusion flame structure and NO emissions with particular attention on thermal and chemical effect of CO2. The biogas flame is modeled by a counter flow diffusion flame and analyzed in mixture fraction space using flamelet approach. The GRI Mech-3.0 mechanism that involves 53 species and 325 reactions is adopted for the oxidation chemistry. It has been observed that flame properties are very sensitive to biogas composition and pressure. CO2 addition decreases flame temperature by both thermal and chemical effects. Added CO2 may participate in chemical reaction due to thermal dissociation (chemical effect). Excessively supplied CO2 plays the role of pure diluent (thermal effect). The ambient pressure rise increases temperature and reduces flame thickness, radiation losses and dissociation amount. At high pressure, recombination reactions coupled with chain carrier radicals reduction, diminishes NO mass fraction.

  20. Statistical Parameter Study of the Time Interval Distribution for Nonparalyzable, Paralyzable, and Hybrid Dead Time Models

    NASA Astrophysics Data System (ADS)

    Syam, Nur Syamsi; Maeng, Seongjin; Kim, Myo Gwang; Lim, Soo Yeon; Lee, Sang Hoon

    2018-05-01

    A large dead time of a Geiger Mueller (GM) detector may cause a large count loss in radiation measurements and consequently may cause distortion of the Poisson statistic of radiation events into a new distribution. The new distribution will have different statistical parameters compared to the original distribution. Therefore, the variance, skewness, and excess kurtosis in association with the observed count rate of the time interval distribution for well-known nonparalyzable, paralyzable, and nonparalyzable-paralyzable hybrid dead time models of a Geiger Mueller detector were studied using Monte Carlo simulation (GMSIM). These parameters were then compared with the statistical parameters of a perfect detector to observe the change in the distribution. The results show that the behaviors of the statistical parameters for the three dead time models were different. The values of the skewness and the excess kurtosis of the nonparalyzable model are equal or very close to those of the perfect detector, which are ≅2 for skewness, and ≅6 for excess kurtosis, while the statistical parameters in the paralyzable and hybrid model obtain minimum values that occur around the maximum observed count rates. The different trends of the three models resulting from the GMSIM simulation can be used to distinguish the dead time behavior of a GM counter; i.e. whether the GM counter can be described best by using the nonparalyzable, paralyzable, or hybrid model. In a future study, these statistical parameters need to be analyzed further to determine the possibility of using them to determine a dead time for each model, particularly for paralyzable and hybrid models.

  1. Role of vanguard counter-potential in terahertz emission due to surface currents explicated by three-dimensional ensemble Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Cortie, D. L.; Lewis, R. A.

    2011-10-01

    The discovery that short pulses of near-infrared radiation striking a semiconductor may lead to emission of radiation at terahertz frequencies paved the way for terahertz time-domain spectroscopy. Previous modeling has allowed the physical mechanisms to be understood in general terms but it has not fully explored the role of key physical parameters of the emitter material nor has it fully revealed the competing nature of the surface-field and photo-Dember effects. In this context, our purpose has been to more fully explicate the mechanisms of terahertz emission from transient currents at semiconductor surfaces and to determine the criteria for efficient emission. To achieve this purpose we employ an ensemble Monte Carlo simulation in three dimensions. To ground the calculations, we focus on a specific emitter, InAs. We separately vary distinct physical parameters to determine their specific contribution. We find that scattering as a whole has relatively little impact on the terahertz emission. The emission is found to be remarkably resistant to alterations of the dark surface potential. Decreasing the band gap leads to a strong increase in terahertz emission, as does decreasing the electron mass. Increasing the absorption dramatically influences the peak-peak intensity and peak shape. We conclude that increasing absorption is the most direct path to improve surface-current semiconductor terahertz emitters. We find for longer pump pulses that the emission is limited by a newly identified vanguard counter-potential mechanism: Electrons at the leading edge of longer laser pulses repel subsequent electrons. This discovery is the main result of our work.

  2. THE USE OF I$sup 125$ LABELED DIIODOFLUORESCEIN IN THE DETECTION OF HUMAN INTRAOCULAR NEOPLASMS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goren, S.B.; Newell, E.W.; Brizel, H.E.

    The new method which is described is believed to be superior to the usual method for detection of intraocular tumors using P/sup 32/. Because of the limited penetration of beta rays, the use of P/sup 32/ imposes relatively strict geometric restrictions and its usefulness in posterior-segment tumors is limited. The patient receives a single intravenous injection of 5.0 mu c/kg body weight of diiodofluorescein-I/sup 125/, the specific activity of which is 17 mg/mc. External counting over each closed eye is carried out with a hand scintillation counter 1, 5, 8, and 24 hr after injection. Ocular counts are performed bymore » resting the window of the counter against the closed lids; the cavernous sinus is measured by placing the counter just above the bridge of the nose. ln the 17 patients studied, eyes with neoplasms contained at least 23% more radioactivity after 8 hr than did the healthy eye. Control eyes, not containing neoplasms (idiopathic retinal detachment, retinoschisis, benign nevus, macular degeneration, phthisis bulbi, absolute glaucoma), showed less than a 13% differential. One false negative test was obtained, a patient with a metastatic bronchogenic adenocarcinoma to the choroid; no false positives were seen. Diiodofluorescein labeled with I/sup 131/ has been widely used as a diagnostic aid in suspected intracranial neoplasms. However, since the gamma rays of I/sup 131/ have a half-value layer in tissue of 6.9 cm, it has not been helpful in ocular disease; the gamma rays arising from the cavernous sinus interfere with accurate counting of intraocular radiation. I/sup 125/ decays by a complicated scheme, the most important as far as ocular studies are concerned being soft photons of 27.3 and 35.4 kev energies. It has a half-value layer in tissue of 1.9 to 2.5 cm. Therefore, it is feasible to measure radiation of the posterior globe with only minimal interference from radiation arising in the brain sinuses. Its half-life of 60 days results in a greatly increased shelf-life of tagged compounds than when I/sup 131/ is used. Additionally, it has a lower energy of radiation than I/sup 131/ which reduces shielding requirements and permits more efficient detector design. These factors permit enhanced counting efficiency and scanning resolution and lead to a decreased dosage of radiation to the patient. It is thus permissible to use the compound in children in whom P/sup 32/ counting is generally considered contraindicated. However, although the total-body irradiation received during this test is not excessive, it has not been used in pregnant women. The administration of Lugol's solution prior to the test prevents excessive concentration of any free circulating radioactive iodine in the thyroid gland. Diiodofluorescein-I/sup 125/ is not retained by intraocular neoplasms for prolonged periods of time, the most significant counts appearing 8 hr after intravenous injection. About 50% of the injected dose is excreted in the urine and feces within the first 24 hr after injection. The absolute count found in the eye after 8 hr is in the order of 40,000 cpm. After 24 hr, this decreases to approximates 15,000 cpm. The ratio of counts over liver, thyroid, eye, and cavernous sinus is about 4 : 2 : 1 : 0.4. The ratio of counts between the 2 eyes is more significant than the absolute number of counts. This may limit the usefulness of this procedure in monocular patients. (H.H.D.)« less

  3. Demonstration of Flying Mirror with Improved Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pirozhkov, Alexander S.; Kando, Masaki; Fukuda, Yuji

    2009-07-25

    A strongly nonlinear wake wave driven by an intense laser pulse can act as a partially reflecting relativistic mirror (the flying mirror)[S. V. Bulanov, et al., Bulletin of the Lebedev Physics Institute, No. 6, 9 (1991); S. V. Bulanov, et al., Phys. Rev. Lett. 91, 085001 (2003)]. Upon reflection from such mirror, a counter-propagating optical-frequency laser pulse is directly converted into high-frequency radiation, with a frequency multiplication factor approx4gamma{sup 2}(the double Doppler effect). We present the results of recent experiment in which the photon number in the reflected radiation was at least several thousand times larger than in our proof-of-principlemore » experiment [M. Kando, et al., Phys. Rev. Lett. 99, 135001 (2007); A. S. Pirozhkov, et al., Phys. Plasmas 14, 123106 (2007)]. The flying mirror holds promise of generating intense coherent ultrashort XUV and x-ray pulses that inherit their temporal shape and polarization from the original optical-frequency (laser) pulses. Furthermore, the reflected radiation bears important information about the reflecting wake wave itself, which can be used for its diagnostics.« less

  4. Radiological implications of granite of northern Pakistan.

    PubMed

    Asghar, M; Tufail, M; Sabiha-Javied; Abid, A; Waqas, M

    2008-09-01

    Granite is an igneous rock that contains natural radioactivity of primordial radionuclides. In Pakistan, granite is distributed in a vast area called the Ambela Granitic Complex (AGC) in North West Frontier Province (NWFP). Granite is a hard rock that exists in different colours and is used to decorate floors, kitchen counter tops, etc. The use of granite in a building as a decor material is a potential source of radiation dose; therefore, natural radioactivity has been measured in 20 granite samples of the AGC with an HPGe (high purity germanium) based gamma ray spectrometer. The average specific activities and their range (given in parentheses) for primordial radionuclides (40)K, (226)Ra and (232)Th were 1218 (899-1927), 659 (46-6120) and 598 (92-3214) Bq kg(-1), respectively. The measured activity concentrations were used for the assessment of hazard indices and radiation dose which were evaluated based on the permissible limits defined for these parameters. The measured specific activities and the derived quantities, hazard indices and radiation dose, have been compared with those given in the literature for these parameters.

  5. Comparison of cosmic rays radiation detectors on-board commercial jet aircraft.

    PubMed

    Kubančák, Ján; Ambrožová, Iva; Brabcová, Kateřina Pachnerová; Jakůbek, Jan; Kyselová, Dagmar; Ploc, Ondřej; Bemš, Július; Štěpán, Václav; Uchihori, Yukio

    2015-06-01

    Aircrew members and passengers are exposed to increased rates of cosmic radiation on-board commercial jet aircraft. The annual effective doses of crew members often exceed limits for public, thus it is recommended to monitor them. In general, the doses are estimated via various computer codes and in some countries also verified by measurements. This paper describes a comparison of three cosmic rays detectors, namely of the (a) HAWK Tissue Equivalent Proportional Counter; (b) Liulin semiconductor energy deposit spectrometer and (c) TIMEPIX silicon semiconductor pixel detector, exposed to radiation fields on-board commercial Czech Airlines company jet aircraft. Measurements were performed during passenger flights from Prague to Madrid, Oslo, Tbilisi, Yekaterinburg and Almaty, and back in July and August 2011. For all flights, energy deposit spectra and absorbed doses are presented. Measured absorbed dose and dose equivalent are compared with the EPCARD code calculations. Finally, the advantages and disadvantages of all detectors are discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Effect of solar energetic particle (SEP) events on the radiation exposure levels to aircraft passengers and crew: Case study of 14 July 2000 SEP event

    NASA Astrophysics Data System (ADS)

    Iles, R. H. A.; Jones, J. B. L.; Taylor, G. C.; Blake, J. B.; Bentley, R. D.; Hunter, R.; Harra, L. K.; Coates, A. J.

    2004-11-01

    We investigate the circumstances required for aircrew and passengers to experience an increased radiation exposure rate from a solar energetic particle (SEP) event occurring during a flight. The effects of the 14 July 2000 National Oceanic and Atmospheric Administration S3 class SEP event are examined using ground-based and satellite measurements together with coincident measurements made using a tissue equivalent proportional counter (TEPC) on board a Virgin Atlantic Airways flight from London Heathrow to Hong Kong. In this paper we present the first measurements made during a SEP event using a TEPC at flight altitudes. Our results indicate that there were no increased radiation levels detected during the flight due to the SEPs, but the measurements agreed well with the CARI-6 model calculations made using a heliocentric potential value derived immediately prior to the SEP event. In addition, a prolonged increase in the >85 MeV particle flux is observed for up to 2 days after the SEP onset by the SAMPEX spacecraft at latitudes >55°.

  7. Distributed performance counters

    DOEpatents

    Davis, Kristan D; Evans, Kahn C; Gara, Alan; Satterfield, David L

    2013-11-26

    A plurality of first performance counter modules is coupled to a plurality of processing cores. The plurality of first performance counter modules is operable to collect performance data associated with the plurality of processing cores respectively. A plurality of second performance counter modules are coupled to a plurality of L2 cache units, and the plurality of second performance counter modules are operable to collect performance data associated with the plurality of L2 cache units respectively. A central performance counter module may be operable to coordinate counter data from the plurality of first performance counter modules and the plurality of second performance modules, the a central performance counter module, the plurality of first performance counter modules, and the plurality of second performance counter modules connected by a daisy chain connection.

  8. QED effects induced harmonics generation in extreme intense laser foil interaction

    NASA Astrophysics Data System (ADS)

    Yu, J. Y.; Yuan, T.; Liu, W. Y.; Chen, M.; Luo, W.; Weng, S. M.; Sheng, Z. M.

    2018-04-01

    A new mechanism of harmonics generation (HG) induced by quantum electrodynamics (QED) effects in extreme intense laser foil interaction is found and investigated by particle-in-cell (PIC) simulations. When two laser pulses with identical intensities of 1.6× {10}24 {{W}} {{{cm}}}-2 are counter-incident on a thin foil target, harmonics emission is observed in their reflected electromagnetic waves. Such harmonics radiation is excited due to transversely oscillating electric currents coming from the vibration of QED effect generated {e}-{e}+ pairs. The effects of laser intensity and polarization were studied. By distinguishing the cascade depth of generated photons and pairs, the influence of QED cascades on HG was analyzed. Although the current HG is not an efficient way for radiation source applications, it may provide a unique way to detect the QED processes in the near future ultra-relativistic laser solid interactions.

  9. Using spread spectrum for AMR magnetic sensor

    NASA Astrophysics Data System (ADS)

    Vala, David

    2016-09-01

    This contribution describe invention of Magnetometer with protection against detection by electronic counter- measure (ECM) registered by Czech patent office as patent no. 305322.1 Magnetic sensors are often part of dual use or security instruments and equipment. For this purpose is very interesting to build sensor with is hidden against electronic countermeasure. In this case is very important level and behavior of electromagnetic noise produced by sensor. And also electromagnetic compatibility of electronic devices is the area which significant grows nowadays too. As the consequence of this growth there is a continuous process of making more strict standards focused on electromagnetic radiation of electronic devices. Sensors technology begins to be a part of these issues due sensors bandwidth increasing and approaching to frequency of radio communication band. Nowadays microcontrollers and similar digital circuits are integrated into sensors devices and it brings new sources of electromagnetic radiation in modern smart sensors.

  10. The role of ocean fluxes and radiative forcings in determining tropical rainfall shifts in RCP8.5 simulations

    NASA Astrophysics Data System (ADS)

    McFarlane, Ashly Ann; Frierson, Dargan M. W.

    2017-08-01

    We use Coupled Model Intercomparison Project global climate models forced with the Representative Concentration Pathway (RCP) 8.5 scenario to attribute tropical precipitation shifts under global warming scenarios and changes in cross-equatorial atmosphere heat transport (c-eq AHT) to changes in ocean and radiative fluxes. We find that the models tend to agree on the sign of c-eq AHT and change in precipitation asymmetry induced by each forcing, but not the magnitude. The ice-albedo feedback and aerosol emission reduction lead to the Northern Hemisphere warming, but this is countered by a reduction to the Atlantic Meridional Overturning Circulation northward heat transport and increased longwave leading to the multimodel mean change in precipitation asymmetry being approximately zero. None of the forcings considered, including aerosol cleanup, can account for more than 20% of the multimodel mean change in c-eq AHT alone.

  11. Measurement of internal radiation exposure among decontamination workers in villages near the crippled Fukushima Daiichi Nuclear Power Plant.

    PubMed

    Tsubokura, Masaharu; Nihei, Masahiko; Sato, Katsumi; Masaki, Shin; Sakuma, Yu; Kato, Shigeaki; Sugimoto, Amina; Nomura, Shuhei; Matsumura, Tomoko; Miyazaki, Makoto; Hayano, Ryugo; Shibuya, Kenji; Kami, Masahiro; Sasaki, Taro

    2013-10-01

    Decontamination workers may face a high risk of exposure to internal irradiation through inhalation during decontamination activities; there is, however, little previous research on the levels of internal contamination during decontamination procedures. The authors reviewed the medical records, including whole body counter measurements, of decontamination workers in villages near the crippled Fukushima Daiichi Nuclear Power Plant to assess their levels of internal radiation exposure. In total, 83 decontamination workers were enrolled in this study. They were regularly engaged in decontamination activities in highly contaminated areas where surface 137Cs deposition density was over 100 kBq m-2. The present study showed low levels of internal exposure among the decontamination workers near the Fukushima Daiichi nuclear plant. The cesium burdens of all the decontamination workers were below detection limits. They had reported no acute health problems. The resuspension of radioactive materials may cause minimal internal contamination during decontamination activities.

  12. Comparison of graphite, aluminum, and TransHab shielding material characteristics in a high-energy neutron field

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Huff, H.; Wilkins, R.; Thibeault, Sheila

    2002-01-01

    Space radiation transport models clearly show that low atomic weight materials provide a better shielding protection for interplanetary human missions than high atomic weight materials. These model studies have concentrated on shielding properties against charged particles. A light-weight, inflatable habitat module called TransHab was built and shown to provide adequate protection against micrometeoroid impacts and good shielding properties against charged particle radiation in the International Space Station orbits. An experiment using a tissue equivalent proportional counter, to study the changes in dose and lineal energy spectra with graphite, aluminum, and a TransHab build-up as shielding, was carried out at the Los Alamos Nuclear Science Center neutron facility. It is a continuation of a previous study using regolith and doped polyethylene materials. This paper describes the results and their comparison with the previous study. Published by Elsevier Science Ltd.

  13. Radiation preservation and test marketing of fruits and vegetables

    NASA Astrophysics Data System (ADS)

    Zhicheng, Xu; Dong, Cai; Fuying, He; Deyao, Zhao

    1993-07-01

    To develop the technology for radiation preservation of fruits and vegetables, many varieties of fruits and vegetables had been researched. Results showed that the low dose irradiation is useful to preservation of fruits and vegetables. On the besis of research, 1900 tons garlic, 950 tons onion, 500 tons potatoes, 710 tons apples and 1000 kg litchi had been irradiated in commercial scale. The quality control standards of irradiated garlic, onion and potato had been established and used for commercial scale irradiation. In order to collect consumers in store response to irradiated foods, a special counter was set up for selling irradiated apples in Nan Jing Road (W), Shanghai. 634 sheets of consumer in-store respense investigation forms have been returned and analysed. These results showed that when consumer understands the benefit of irradiation preservation such as higher quality, greater safety, longer shelf-live, wide product availability, or good prices for value, consumer would willingly buy irradiated food.

  14. On the optimisation of the use of 3He in radiation portal monitors

    NASA Astrophysics Data System (ADS)

    Tomanin, Alice; Peerani, Paolo; Janssens-Maenhout, Greet

    2013-02-01

    Radiation Portal Monitors (RPMs) are used to detect illicit trafficking of nuclear or other radioactive material concealed in vehicles, cargo containers or people at strategic check points, such as borders, seaports and airports. Most of them include neutron detectors for the interception of potential plutonium smuggling. The most common technology used for neutron detection in RPMs is based on 3He proportional counters. The recent severe shortage of this rare and expensive gas has created a problem of capacity for manufacturers to provide enough detectors to satisfy the market demand. In this paper we analyse the design of typical commercial RPMs and try to optimise the detector parameters in order either to maximise the efficiency using the same amount of 3He or minimise the amount of gas needed to reach the same detection performance: by reducing the volume or gas pressure in an optimised design.

  15. MONTE CARLO SIMULATION OF THE BREMSSTRAHLUNG RADIATION FOR THE MEASUREMENT OF AN INTERNAL CONTAMINATION WITH PURE-BETA EMITTERS IN VIVO.

    PubMed

    Fantínová, K; Fojtík, P; Malátová, I

    2016-09-01

    Rapid measurement techniques are required for a large-scale emergency monitoring of people. In vivo measurement of the bremsstrahlung radiation produced by incorporated pure-beta emitters can offer a rapid technique for the determination of such radionuclides in the human body. This work presents a method for the calibration of spectrometers, based on the use of UPh-02T (so-called IGOR) phantom and specific (90)Sr/(90)Y sources, which can account for recent as well as previous contaminations. The process of the whole- and partial-body counter calibration in combination with application of a Monte Carlo code offers readily extension also to other pure-beta emitters and various exposure scenarios. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. End-to-end system test for solid-state microdosemeters.

    PubMed

    Pisacane, V L; Dolecek, Q E; Malak, H; Dicello, J F

    2010-08-01

    The gold standard in microdosemeters has been the tissue equivalent proportional counter (TEPC) that utilises a gas cavity. An alternative is the solid-state microdosemeter that replaces the gas with a condensed phase (silicon) detector with microscopic sensitive volumes. Calibrations of gas and solid-state microdosemeters are generally carried out using radiation sources built into the detector that impose restrictions on their handling, transportation and licensing in accordance with the regulations from international, national and local nuclear regulatory bodies. Here a novel method is presented for carrying out a calibration and end-to-end system test of a microdosemeter using low-energy photons as the initiating energy source, thus obviating the need for a regulated ionising radiation source. This technique may be utilised to calibrate both a solid-state microdosemeter and, with modification, a TEPC with the higher average ionisation energy of a gas.

  17. Ab-Initio analysis of TlBr: limiting the ionic current without degrading the electronic one

    NASA Astrophysics Data System (ADS)

    Rocha Leao, Cedric; Lordi, Vincenzo

    2011-03-01

    Although TlBr in principle presents all the theoretical requirements for making high resolution room temperature radiation detectors, practical applications of TlBr have proven to be nonviable due to the polarization that is observed in the crystal after relatively short periods of operation. This polarization, that is believed to be caused by accumulation of oppositely charged ionic species at the ends of the crystal, results in an electric field that opposes that of the applied bias, counter-acting its effect. In this work, we use state of the art quantum modeling to benchmark the theoretical limits for the performance of TlBr as a radiation detector, showing that the best experimental reports demonstrate near-ideal electronic characteristics. We then propose a model to inhibit the detrimental ionic current in the material without impacting the excellent properties of the electronic current. Prepared by LLNL under Contract DE-AC52-07NA27344.

  18. Measurements on the shuttle of the LET spectra of galactic cosmic radiation and comparison with the radiation transport model

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Cucinotta, F. A.; Braby, L. A.; Konradi, A.; Wilson, J. W. (Principal Investigator)

    1994-01-01

    A new class of tissue-equivalent proportional counters has been flown on two space shuttle flights. These detectors and their associated electronics cover a lineal energy range from 0.4 to 1250 keV/microns with a multichannel analyzer resolution of 0.1 keV/microns from 0.4 to 20 keV/microns and 5 keV/microns from 20 to 1250 keV/microns. These detectors provide the most complete dynamic range and highest resolution of any technique currently in use. On one mission, one detector was mounted in the Shuttle payload bay and another older model in the mid-deck, thus providing information on the depth dependence of the lineal energy spectrum. A detailed comparison of the observed lineal energy and calculated LET spectra for galactic cosmic radiation shows that, although the radiation transport models provide a rather accurate description of the dose (+/- 15%) and equivalent dose (+/- 15%), the calculations significantly underestimate the frequency of events below about 100 keV/microns. This difference cannot be explained by the inclusion of the contribution of splash protons. The contribution of the secondary pions, kaons and electrons produced in the Shuttle shielding, if included in the radiation transport model, may explain these differences. There are also significant differences between the model predictions and observations above 140 keV/microns, particularly for 28.5 degrees inclination orbit.

  19. Comparison of ground-based measurements of natural radiation to airborne radiation survey data on transects from coastal California to the Colorado Plateau

    NASA Astrophysics Data System (ADS)

    Stoffer, P. W.; Hernández, L.; Messina, P.; Dearaujo, J.; Li, A.; Hicks, A.; White, L.

    2008-12-01

    Natural gamma radiation measurements were collected with a hand-held Geiger counter at nearly 400 locations on two general transects across the southwestern United States. The data are used to provide ground-truth comparison to published airborne radiation surveys of the region. The first transect was collected by high school students in the SF-ROCKS program at San Francisco State University in the summer of 2008 starting in San Francisco. Data were collected across the Sierra Nevada Range on I-80, and across Highway 50 in Nevada, and I-70 in Utah. Data were collected in and around Great Basin, Arches, Capitol Reef, Bryce, and Zion National Parks, and Grand Staircase-Escalante National Monument. A second transect extends from San José, California to Flagstaff, Arizona and includes the Mojave National Reserve, Death Valley region, and locations throughout the Navajo Reservation region in northern Arizona and western New Mexico. Radiation data (with GPS reference) were collected from all the major sedimentary rock formations and igneous rocks of the Colorado Plateau and from many igneous and metamorphic rocks throughout the Great Basin and southern California deserts. Anomalously high localized levels were noted in selected sedimentary units associated with uranium exploration targets in the Colorado Plateau region, and in caverns and rock fissures where radon gas (and accumulation of derivative fission products) are the inferred sources.

  20. The NASA Space Radiobiology Risk Assessment Project

    NASA Astrophysics Data System (ADS)

    Cucinotta, Francis A.; Huff, Janice; Ponomarev, Artem; Patel, Zarana; Kim, Myung-Hee

    The current first phase (2006-2011) has the three major goals of: 1) optimizing the conventional cancer risk models currently used based on the double-detriment life-table and radiation quality functions; 2) the integration of biophysical models of acute radiation syndromes; and 3) the development of new systems radiation biology models of cancer processes. The first-phase also includes continued uncertainty assessment of space radiation environmental models and transport codes, and relative biological effectiveness factors (RBE) based on flight data and NSRL results, respectively. The second phase of the (2012-2016) will: 1) develop biophysical models of central nervous system risks (CNS); 2) achieve comphrensive systems biology models of cancer processes using data from proton and heavy ion studies performed at NSRL; and 3) begin to identify computational models of biological countermeasures. Goals for the third phase (2017-2021) include: 1) the development of a systems biology model of cancer risks for operational use at NASA; 2) development of models of degenerative risks, 2) quantitative models of counter-measure impacts on cancer risks; and 3) indiviudal based risk assessments. Finally, we will support a decision point to continue NSRL research in support of NASA's exploration goals beyond 2021, and create an archival of NSRL research results for continued analysis. Details on near term goals, plans for a WEB based data resource of NSRL results, and a space radiation Wikepedia are described.

  1. Fast, Power-Rich Space Transportation Key to Human Space Exploration and Survival

    NASA Astrophysics Data System (ADS)

    Chang-Diaz, F.

    2002-01-01

    above the rest: Physiological debilitation, radiation sickness and psychological stress. Many counter-measures are presently being considered to ameliorate these difficulties; however, in the long run, two important new developments are required: abundant space power and advanced propulsion. Recent initiatives are beginning to focus on these long-term issues. As a result, important technologies currently in the conceptual realm are now being considered for rapid test and deployment. This presentation discusses the promises and the challenges of the new approaches and the profound impact they will have on our capability to survive and explore our new human frontier.

  2. X ray absorption by dark nebulae (HEAO-2 guest investigator program)

    NASA Technical Reports Server (NTRS)

    Sanders, W. T.

    1991-01-01

    A study is described of data obtained from the Imaging Proportional Counter (IPC) x ray detector aboard the HEAO-2 satellite (Einstein Observatory). The research project involved a search for absorption of diffuse low energy x ray background emission by galactic dark nebulae. The commonly accepted picture that the bulk of the C band emission originates locally, closer that a few hundred parsec, and the bulk of the M band emission originates farther away than a few hundred parsec, was tested. The idea was to look for evidence of absorption of the diffuse background radiation by nearby interstellar clouds.

  3. The HEAO-A Scanning Modulation Collimator instrument

    NASA Technical Reports Server (NTRS)

    Roy, A.; Ballas, J.; Jagoda, N.; Mckinnon, P.; Ramsey, A.; Wester, E.

    1977-01-01

    The Scanning Modulation Collimator X-ray instrument for the HEAO-A satellite was designed to measure celestial radiation in the range between 1 and 15 KeV and to resolve, and correlate, the position of X-ray sources with visible light sources on the celestial sphere to within 5 arc seconds. The positional accuracy is made possible by mechanical collimation of the X-ray sources viewed by the instrument. High sensitivity is provided from two systems each containing four gas filled proportional counters followed by preamplification, signal summing, pulse height analysis, pulse shape discrimination, X-ray event accumulators and telemetry processing electronics.

  4. Nanodosimetry of electrons: analysis by experiment and modelling.

    PubMed

    Bantsar, A; Pszona, S

    2015-09-01

    Nanodosimetry experiments for high-energy electrons from a (131)I radioactive source interacting with gaseous nitrogen with sizes on a scale equivalent to the mass per area of a segment of DNA and nucleosome are described. The discrete ionisation cluster-size distributions were measured in experiments carried out with the Jet Counter. The experimental results were compared with those obtained by Monte Carlo modelling. The descriptors of radiation damages have been derived from the data obtained from ionisation cluster-size distributions. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Wernher von Braun

    NASA Image and Video Library

    1959-03-01

    In this photo, Director of the U.S. Army Ballistic Missile Agency's (ABMA) Development Operations Division, Dr. Wernher von Braun, and Director of Missile Firing Division, Dr. Kurt Debus, are shown with unidentified individuals, discussing two components that would make up the Pioneer IV Lunar Probe. The mercury batteries (left) were used to power the radio transmitter, cosmic radiation counter and other instruments in Pioneer IV. The conical shroud placed over the instruments of Pioneer IV was plated with gold to improve conductivity. The metal surface also served as the anterna for the probe's instruments signaling back to the Earth receiving stations.

  6. REVIEWS OF TOPICAL PROBLEMS: Neutrinos from stellar core collapses: present status of experiments

    NASA Astrophysics Data System (ADS)

    Ryazhskaya, Ol'ga G.

    2006-10-01

    The responses of the existing underground detectors to neutrino bursts from collapsing stars evolving in accordance with various models are considered. The interpretation of the results of detecting neutrino radiation from the SN1987A supernova explosion is discussed. A combination of large scintillation counters interlayered with iron slabs (as a target for the electron neutrino interaction) is suggested as a detector for core collapse neutrinos. Bounds for the galactic rate of core collapses based on 28 years of observations by neutrino telescopes of RAS INR, LSD, and LVD detectors are presented.

  7. A LiF and BeO TLD based microdosimeter for space radiation risk assessment of astronauts

    NASA Astrophysics Data System (ADS)

    Mukherjee, B.

    2018-06-01

    The ratio of thermoluminescence glow curve area of BeO and LiF dosimeters was found to be proportional to average LET and quality factor (Q) of impinging mixed radiations. Using this phenomenon and widely available Thermoluminescence Dosimeter TLD-700 (7LiF: Mg,Ti) and BeO (Thermolux 995) chips a TLD-Microdosimeter (LiBe-14) emulating a much larger gas-filled Tissue Equivalent Proportional Counter (TEPC) was developed. The TEPC is an essential device of space radiation dosimetry widely used by international space agencies. The LiBe-14 is capable of assessing the LETTissue (5–300 keV/μm), quality factor Q (1–30) and associated dose equivalent H (0.1–1000 mSv) of any mixed radiation fields of interest, including space radiations predominant in Low Earth Orbit (LEO) environment. The TLD microdosimeter was calibrated using the secondary radiation fields produced by bombarding a 25 cm × 25 cm × 35 cm polystyrene phantom with 81, 119, 150, 177, 201 and 231 MeV protons from a Proton Therapy Medical Cyclotron. The TLD pair (BeO/LiF) was attached to the TEPC and placed lateral to the proton beam. The characteristics of space radiation inside the spacecraft are complex. Hence, personal dosimetry of astronauts in the space habitat is performed using "multi-element" dosimeters made of different types of TLD and CR-39 plastic nuclear track detector (PNTD). The TLD and PNTD are used to assess the sparsely (low LET) and densely (high LET) ionising radiation component respectively. This report elucidates the feasibility of LiBe-14 microdosimeter for the estimation of overall dose equivalent and "risk of exposure induced death" (REID) of astronauts working in LEO space stations.

  8. Radiation protection and environmental management at the relativistic heavy ion collider.

    PubMed

    Musolino, S V; Briggs, S L; Stevens, A J

    2001-01-01

    The Relativistic Heavy Ion Collider (RHIC) is a high energy hadron accelerator built to study basic nuclear physics. It consists of two counter-rotating beams of fully stripped gold ions that are accelerated in two rings to an energy of 100 GeV/nucleon or protons at 250 GeV/c. The beams can be stored for a period of five to ten hours and brought into collision for experiments during that time. The first major physics objective is to recreate a state of matter, the quark-gluon plasma, that has been predicted to have existed at a short time after the creation of the universe. Because there are only a few other high energy particle accelerators like RHIC in the world, the rules promulgated in the US Code of Federal Regulations under the Atomic Energy Act, State regulations, or international guidance documents do not cover prompt radiation from accelerators to govern directly the design and operation of a superconducting collider. Special design criteria for prompt radiation were developed to provide guidance tor the design of radiation shielding. Environmental Management at RHIC is accomplished through the ISO 14001 Environmental Management System. The applicability, benefits, and implementation of ISO 14001 within the framework of a large research accelerator complex are discussed in the paper.

  9. Radioprotective properties of apple polyphenols: an in vitro study.

    PubMed

    Chaudhary, Pankaj; Shukla, Sandeep Kumar; Kumar, I Prem; Namita, I; Afrin, Farhat; Sharma, Rakesh Kumar

    2006-08-01

    Present study was undertaken to evaluate the radioprotective ability of total polyphenols extracted from edible portion (epicarp and mesocarp) of apple. Prior administration of apple polyphenols to murine thymocytes significantly countered radiation induced DNA damage (evaluated by alkaline halo assay) and cell death (trypan blue exclusion method) in a dose dependent manner maximally at a concentration of 2 and 0.2 mg/ml respectively. Apple polyphenols in a dose dependent fashion inhibited both radiation or Fenton reaction mediated 2-deoxyribose (2-DR) degradation indicating its ability to scavenge hydroxyl radicals and this activity was found to be unaltered in presence of simulated gastric juice. Similarly apple polyphenols in a dose dependent fashion scavenged DPPH radicals (maximum 69% at 1 mg/ml), superoxide anions (maximum 88% at 2 mg/ml), reduced Fe(3 +) to Fe(2 +) (maximum at 1 mg/ml) and inhibited Fenton reaction mediated lipid peroxidation (maximum 66% at 1.5 mg/ml) further establishing its antioxidative properties. Studies carried out with plasmid DNA revealed the ability of apple polyphenols to inhibit radiation induced single as well as double strand breaks. The results clearly indicate that apple polyphenols have significant potential to protect cellular system from radiation induced damage and ability to scavenge free radicals might be playing an important role in its radioprotective manifestation.

  10. Comprehensive data on ionising radiation from Fukushima Daiichi nuclear power plant in the town of Miharu, Fukushima Prefecture: The Misho Project.

    PubMed

    Koike, T; Suzuki, Y; Genyu, S; Kobayashi, I; Komori, H; Otsu, H; Sakuma, H; Sakuma, K; Sarausad, E M; Shimada, K; Shinozuka, T; Tamura, H; Tsukada, K; Ukai, M; Yamamoto, T O

    2014-09-01

    Data related to radioactivity released from the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident on 15 March 2011 gathered by residents of Miharu, Fukushima Prefecture, and by Tohoku University are presented. These data sets consist of (1) the earliest radiation monitoring by a Geiger counter in the town, (2) ratios of radioactivity between (132)Te and (137)Cs for a wide area between Fukushima and Tokyo, (3) radiation measurement of soil samples collected from 18 school grounds, and (4) external radiation exposure of 1400 students using OSL badges. By combining and analysing these various data sets, a curve for the cumulative total external exposure as a function of time, with 16 : 00 h on 15 March 2011 being time zero, is obtained. The average cumulative external dosage is estimated to be 10 mSv (σ = 4.2 mSv) over 10 years. In addition, the initiative that the residents of Miharu took in response to the FDNPP accident, which became known as The Misho Project (MP), is documented; in particular, the time at which the municipality instructed the immediate ingestion of iodine tablets by those under the age of 40, 13 : 00 h on 15 March 2011, is assessed.

  11. Public relations and the radiation processing industry

    NASA Astrophysics Data System (ADS)

    Coates, T. Donna

    The world's uneasiness and mistrust regarding anything nuclear has heightened in recent years due to events such as Chernobyl and Three Mile Island. Opinion polls and attitude surveys document the public's growing concern about issues such as the depletion of the ozone layer, the resulting greenhouse effect and exposure of our planet to cosmic radiation. Ultimately, such research reveals an underlying fear regarding the unseen impacts of modern technology on the environment and on human health. These concerns have obvious implications for the radiation processing industry, whose technology is nuclear based and not easily understood by the public. We have already seen organized nuclear opponents mobilize public anxiety, fear and misunderstanding in order to oppose the installation of radiation processing facilities and applications such as food irradiation. These opponents will no doubt try to strengthen resistance to our technology in the future. Opponents will attempt to convince the public that the risks to public and personal health and safety outweigh the benefits of our technology. We in the industry must head off any tendency for the public to see us as the "enemy". Our challenge is to counter public uneasiness and misunderstanding by effectively communicating the human benefits of our technology. Clearly it is a challenge we cannot afford to ignore.

  12. SOLAR COSMIC RAYS AND SOFT RADIATION OBSERVED AT 5,000,000 KILOMETERS FROM EARTH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnoldy, R.L.; Hoffman, R.A.; Winckler, J.R.

    1960-09-01

    During the period Mar. 27 to Apr. 6, 1960, the integrating ionization chamber and Geiger counter in Pioneer V detected solar cosmic rays and some soft- radiation effects associated with a high level of solar activity. The space probe was 5 x 10/sup 6/ km from the earth, approximately in the plane of the ecliptic, and located somewhat behind the sunearth radius toward the sun. The solar activity was associated with McMath plage region 5615 and was characterized by numerous flares of all sizes, large loops and surge prominences, and strong emission over a wide range of frequencies. On Mar.more » 31 at 0800 UT, a severe geomagnetic storm began on earth accompanied by major earth-current disturbances, a complete blackout of the North Atlantic communications channel, and auroral displays. At the same time, a large Forbush decrease occurred in the galactic cosmic radiation. An intense series of balloon flights was conducted to record the counting-rate increases at high altitudes due to solar cosmic rays and auroral x rays. Explorer VII showed substantial changes in the radiation belts and detected the solar cosmic rays. The observations of Pioneer V are summarized and compared to the findings of Explorer VII for the same period. (B.O.G.)« less

  13. Development of a Nanomaterial Anode for a Low-Voltage Proportional Counter for Neutron Detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Craps, Matthew Greg

    NanoTechLabs (NTL) in collaboration with the Savannah River National Laboratory (SRNL) and Clemson University have continued development of a next generation proportional counter (PC) for neutron detection utilizing robust, inexpensive nanostructured anodes while maximizing neutron capture. Neutron detectors are vital to national security as they can be used to detect illicit trafficking of radioactive materials, which could mean the presence of or planning of a dirty bomb attack. Typical PCs operate with high bias potentials that create electronic noise. Incorporating nanomaterials into the anode of PCs can theoretically operate at low voltages (eg. 10-300V) due to an increase in themore » electric field associated with a smaller diameter nano-scale anode. In addition to the lower operating voltage, typical high PC voltages (500-1200V) could be used to generate a larger electric field resulting in more electrons being collected, thus increasing the sensitivity of the PC. Other advantages of nano-PC include reduced platform size, weight, cost, and improved ruggedness. Clemson modeled the electric field around the CNT array tips. NTL grew many ordered CNT arrays as well as control samples and densified the arrays to improve the performance. The primary objective for this work is to provide evidence of a commercially viable technique for reducing the voltage of a parallel plate proportional counter using nanosized anodes. The parallel plate geometry has advantages over the typical cylindrical design based on more feasible placement of solid neutron absorbers and more geometrically practical windows for radiation capture and directional detection.« less

  14. The Origin of the UCSD X-ray Astronomy Program - A Personal Perspective

    NASA Astrophysics Data System (ADS)

    Peterson, Laurence E.

    2013-01-01

    I was a graduate student in the late 1950’s at the University of Minnesota in the Cosmic Ray Group under Prof. John R. Winckler. He had a project monitoring Cosmic ray time variations from an extensive series of balloon flights using simple detectors during the International Geophysical Year 1957-58. During the 20 March 1958 flight, a short 18 sec. burst of high energy radiation was observed simultaneously with a class II Solar flare. From the ratio of the Geiger counter rate to the energy loss in the ionization chamber, it was determined this radiation was likely hard X-rays or low-energy gamma rays and not energetic particles. Further analysis using information from other concurrent observations indicated the X-rays were likely due to Bremsstrahlung from energetic electrons accelerated in the solar flare magnetic field; these same electrons produced radio emissions. This first detection of extra-terrestrial X- or gamma rays showed the importance of non-thermal processes in Astrophysical phenomena. Winckler and I were interested by the possibility of non-solar hard X-rays. While completing my thesis on a Cosmic ray topic, I initiated a balloon program to develop more sensitive collimated low-background scintillation counters. This led to a proposal to the newly formed NASA to place an exploratory instrument on the 1st Orbiting Solar Observatory launched 7 March 1962. In August that year, I assumed a tenure-track position at UCSD; the data analysis of OSO-1 and the balloon program were transferred to UCSD to initiate the X-ray Astronomy program. The discovery of Cosmic X-ray sources in the 1-10 Kev range on a rocket flight in June 1962 by Giacconi and colleagues gave impetus to the UCSD activities. It seemed evident cosmic X-ray sources could be detected above 20 Kev using high-flying balloons. Early results included measurements of the 50 million K gas in SCO X-1, and the X-ray continuum from the Crab Nebula characterized by a power-law dN/dE ~ E-2.2. The instrument developments resulted in ever more sophisticated and sensitive counter systems. Follow-on instruments were flown on OSO-III and OSO-VII by the early 70’s, the HEAO-1 in 1976, and the RXTE in 1995. These provided many new results on Cosmic X-rays.

  15. Improvements to the Ionizing Radiation Risk Assessment Program for NASA Astronauts

    NASA Technical Reports Server (NTRS)

    Semones, E. J.; Bahadori, A. A.; Picco, C. E.; Shavers, M. R.; Flores-McLaughlin, J.

    2011-01-01

    To perform dosimetry and risk assessment, NASA collects astronaut ionizing radiation exposure data from space flight, medical imaging and therapy, aviation training activities and prior occupational exposure histories. Career risk of exposure induced death (REID) from radiation is limited to 3 percent at a 95 percent confidence level. The Radiation Health Office at Johnson Space Center (JSC) is implementing a program to integrate the gathering, storage, analysis and reporting of astronaut ionizing radiation dose and risk data and records. This work has several motivations, including more efficient analyses and greater flexibility in testing and adopting new methods for evaluating risks. The foundation for these improvements is a set of software tools called the Astronaut Radiation Exposure Analysis System (AREAS). AREAS is a series of MATLAB(Registered TradeMark)-based dose and risk analysis modules that interface with an enterprise level SQL Server database by means of a secure web service. It communicates with other JSC medical and space weather databases to maintain data integrity and consistency across systems. AREAS is part of a larger NASA Space Medicine effort, the Mission Medical Integration Strategy, with the goal of collecting accurate, high-quality and detailed astronaut health data, and then securely, timely and reliably presenting it to medical support personnel. The modular approach to the AREAS design accommodates past, current, and future sources of data from active and passive detectors, space radiation transport algorithms, computational phantoms and cancer risk models. Revisions of the cancer risk model, new radiation detection equipment and improved anthropomorphic computational phantoms can be incorporated. Notable hardware updates include the Radiation Environment Monitor (which uses Medipix technology to report real-time, on-board dosimetry measurements), an updated Tissue-Equivalent Proportional Counter, and the Southwest Research Institute Radiation Assessment Detector. Also, the University of Florida hybrid phantoms, which are flexible in morphometry and positioning, are being explored as alternatives to the current NASA computational phantoms.

  16. Space Radiation Induced Cytogenetic Damage in the Blood Lymphocytes of Astronauts

    NASA Technical Reports Server (NTRS)

    George, K.; Cucinotta, F. A.

    2008-01-01

    Cytogenetic analysis of astronauts blood lymphocytes provides a direct in vivo measurement of space radiation damage, which takes into account individual radiosensitivity and considers the influence of microgravity and other stress conditions. We present our latest analyses of chromosome damage in astronauts blood lymphocytes assessed by fluorescence in situ hybridization (FISH) chromosome painting and collected at various times beginning directly after return from space to several years after flight. Dose was derived from frequencies of chromosome exchanges using preflight calibration curves, and the Relative Biological Effect (RBE) was estimated by comparison with individually measured physically absorbed doses. Values for average RBE were compared to the average quality factor (Q), from direct measurements of the lineal energy spectra using a tissue-equivalent proportional counter (TEPC) and radiation transport codes. Results prove that cytogenetic biodosimetry analyses on blood collected within a week or two of return from space provides a reliable estimate of equivalent radiation dose and risk after protracted exposure to space radiation of a few months or more. However, data collected several months or years after flight suggests that the yield of chromosome translocations may decline with time after the mission, indicating that retrospective doses may be more difficult to estimate. In addition, limited data on multiple flights show a lack of correlation between time in space and translocation yields. Data from one crewmember, who has participated in two separate long-duration space missions and has been followed up for over 10 years, provide limited information on the effect of repeat flights and show a possible adaptive response to space radiation exposure.

  17. Development of an Ultra-Low Background Liquid Scintillation Counter for Trace Level Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Erchinger, Jennifer L.; Orrell, John L.; Aalseth, Craig E.

    2015-09-01

    Low-level liquid scintillation counting (LSC) has been established as one of the radiation detection techniques useful in elucidating environmental processes and environmental monitoring around nuclear facilities. The Ultra-Low Background Liquid Scintillation Counter (ULB-LSC) under construction in the Shallow Underground Laboratory at Pacific Northwest National Laboratory aims to further reduce the MDAs and/or required sample processing. Through layers of passive shielding in conjunction with an active veto and 30 meters water equivalent overburden, the background reduction is expected to be 10 to 100 times below typical analytic low-background liquid scintillation systems. Simulations have shown an expected background of around 14 countsmore » per day. A novel approach to the light collection will use a coated hollow light guide cut into the inner copper shielding. Demonstration LSC measurements will show low-energy detection, spectral deconvolution, and alpha/beta discrimination capabilities, from trials with standards of tritium, strontium-90, and actinium-227, respectively. An overview of the system design and expected demonstration measurements will emphasize the potential applications of the ULB-LSC in environmental monitoring for treaty verification, reach-back sample analysis, and facility inspections.« less

  18. Melanins in Fossil Animals: Is It Possible to Infer Life History Traits from the Coloration of Extinct Species?

    PubMed Central

    Negro, Juan J.; Finlayson, Clive; Galván, Ismael

    2018-01-01

    Paleo-colour scientists have recently made the transition from describing melanin-based colouration in fossil specimens to inferring life-history traits of the species involved. Two such cases correspond to counter-shaded dinosaurs: dark-coloured due to melanins dorsally, and light-coloured ventrally. We believe that colour reconstruction of fossils based on the shape of preserved microstructures—the majority of paleo-colour studies involve melanin granules—is not without risks. In addition, animals with contrasting dorso-ventral colouration may be under different selection pressures beyond the need for camouflage, including, for instance, visual communication or ultraviolet (UV) protection. Melanin production is costly, and animals may invest less in areas of the integument where pigments are less needed. In addition, melanocytes exposed to UV radiation produce more melanin than unexposed melanocytes. Pigment economization may thus explain the colour pattern of some counter-shaded animals, including extinct species. Even in well-studied extant species, their diversity of hues and patterns is far from being understood; inferring colours and their functions in species only known from one or few specimens from the fossil record should be exerted with special prudence. PMID:29360744

  19. High-harmonic generation by two-color mixing of circularly polarized laser fields

    NASA Astrophysics Data System (ADS)

    Milošević, D. B.; Becker, W.; Kopold, R.

    2000-06-01

    Dipole selection rules prevent harmonic generation by an atom in a circularly polarized laser field. However, this is not the case for a superposition of several circularly polarized fields, such as two circularly polarized fields with frequencies ω and 2ω that corotate or counter-rotate in the same plane. Harmonic generation in this environment has been observed and, in fact, found to be very intense in the counter-rotating case [1]. In a certain frequency region, the harmonics may be stronger than those radiated in a linearly polarized field of either frequency. The selection rules dictate that the harmonics are circularly polarized with a helicity that alternates from one harmonic to the next. Besides their practical interest, these harmonics are also intriguing from a fundamental point of view: the standard simple-man picture does not apply since orbits that start with zero velocity in this field almost never return to their point of departure. In terms of quantum trajectories, we discuss the mechanism that generates these harmonics. In several interesting ways, it is complementary to the case of linear polarization. [1] H. Eichmann et al., Phys. Rev. A 51, R3414 (1995)

  20. Modelling a man-portable air-defence (MANPAD) system with a rosette scan two-colour infrared (IR) and ultraviolet (UV) seeker

    NASA Astrophysics Data System (ADS)

    Kumar, Devinder; Smith, Leon; Richardson, Mark A.; Ayling, Richard; Barlow, Nick

    2014-10-01

    The Ultraviolet (UV) band of the electromagnetic (EM) spectrum has the potential to be used as the host medium for the operation of guided weapons. Unlike in the Infrared (IR), a target propelled by an air breathing jet engine produces no detectable radiation in the UV band, and is opaque to the background UV produced by the Sun. Successful engineering of spectral airborne IR countermeasures (CM) against existing two colour IR seekers has encouraged missile counter-countermeasure (CCM) designers to utilise the silhouette signature of an aircraft in the UV as a means of distinguishing between a true target and a flare CM. In this paper we describe the modelling process of a dual band IR and UV rosette scan seeker using CounterSim, a missile engagement and countermeasure simulation software package developed by Chemring Countermeasures Ltd. Results are shown from various simulated engagements of the dual band MANPAD with a C-130 Hercules modelled by Chemring Countermeasures. These results have been used to estimate the aircrafts' vulnerability to this MANPAD threat. A discussion on possible future optical countermeasures against dual band IR-UV seekers is given in conclusion to the simulation results.

  1. CCN activity of thermodenuded aerosol particles downwind of the Sacramento area urban plume

    NASA Astrophysics Data System (ADS)

    Hiranuma, N.; Cziczo, D. J.; Nelson, D.; Zhang, Q.; Setyan, A.; Song, C.; Shrivastava, M.; Shilling, J. E.

    2010-12-01

    This study focuses on the characterization of cloud condensation nuclei (CCN) properties of aerosol particles measured during the Carbonaceous Aerosols and Radiative Effects Study (CARES) near Sacramento, CA in June 2010. Supersaturation-dependant CCN activity (0.07 - 0.5% supersaturation) was measured with DMT CCN counters at two locations; one near the city center (T0) and the other in Cool, CA, a small town located ~40 kilometers downwind of the urban plume in the Sierra Nevada foothills (T1). The T1 CCN counter was operated behind a thermodenuder to study volatility-dependant CCN activity of the urban aerosol plume as it was transported into the biogenically influenced foothills. Preliminary analysis indicated that activated fraction was inversely proportional to the thermodenuder temperature, suggesting that the more-volatile fraction of the aerosol might have played an important role in the CCN activity of the aerosol. The relationship between the chemical composition and CCN activity of the aerosol will be discussed. The physical and chemical transformations of particles aged in the foothills as well as the diurnal profiles of CCN both at T0 and T1 will also be discussed for the transport event of 15 June 2010.

  2. Analysis of X-ray observations of the 15 June 1973 flare in active region NOAA 131

    NASA Technical Reports Server (NTRS)

    Krall, K. R.; Reichmann, E. J.; Wilson, R. M.; Henze, W., Jr.; Smith, J. B., Jr.

    1978-01-01

    Observations and analyses of the 1B/M3 flare of 15 June, 1973 in active region NOAA 131 (McMath 12379) are presented. The X-ray observations, consisting of broadband photographs and proportional counter data from the Skylab/ATM NASA-MSFC/Aerospace S-056 experiment, are used to infer temperatures, emission measures, and densities for the flaring plasma. The peak temperature from the spatially resolved photographs is 25,000,000 K, while the temperature from the full-disk proportional counter data is approximately 15,000,000 K. The density is 3 times 10 to the 10th/cu cm. The X-ray flare emission appears to come primarily from two low-lying curvilinear features lying perpendicular to and centered on the line where the photospheric longitudinal magnetic field is zero. Similarities in the preflare and postflare X-ray emission patterns indicate that no large-scale relaxation of the coronal magnetic configuration was observed. Also discussed are H-alpha and magnetic field observations of the flare and the active region. Finally, results of numerical calculations, including thermal conduction, radiative loss, and chromospheric evaporation, are in qualitative agreement with the decay phase observations.

  3. Global Gradients of Coral Exposure to Environmental Stresses and Implications for Local Management

    PubMed Central

    Maina, Joseph; McClanahan, Tim R.; Venus, Valentijn; Ateweberhan, Mebrahtu; Madin, Joshua

    2011-01-01

    Background The decline of coral reefs globally underscores the need for a spatial assessment of their exposure to multiple environmental stressors to estimate vulnerability and evaluate potential counter-measures. Methodology/Principal Findings This study combined global spatial gradients of coral exposure to radiation stress factors (temperature, UV light and doldrums), stress-reinforcing factors (sedimentation and eutrophication), and stress-reducing factors (temperature variability and tidal amplitude) to produce a global map of coral exposure and identify areas where exposure depends on factors that can be locally managed. A systems analytical approach was used to define interactions between radiation stress variables, stress reinforcing variables and stress reducing variables. Fuzzy logic and spatial ordinations were employed to quantify coral exposure to these stressors. Globally, corals are exposed to radiation and reinforcing stress, albeit with high spatial variability within regions. Based on ordination of exposure grades, regions group into two clusters. The first cluster was composed of severely exposed regions with high radiation and low reducing stress scores (South East Asia, Micronesia, Eastern Pacific and the central Indian Ocean) or alternatively high reinforcing stress scores (the Middle East and the Western Australia). The second cluster was composed of moderately to highly exposed regions with moderate to high scores in both radiation and reducing factors (Caribbean, Great Barrier Reef (GBR), Central Pacific, Polynesia and the western Indian Ocean) where the GBR was strongly associated with reinforcing stress. Conclusions/Significance Despite radiation stress being the most dominant stressor, the exposure of coral reefs could be reduced by locally managing chronic human impacts that act to reinforce radiation stress. Future research and management efforts should focus on incorporating the factors that mitigate the effect of coral stressors until long-term carbon reductions are achieved through global negotiations. PMID:21860667

  4. Thyroid Consequences of the Fukushima Nuclear Reactor Accident

    PubMed Central

    Nagataki, Shigenobu

    2012-01-01

    Background A special report, ‘The Fukushima Accident’, was delivered at the 35th Annual Meeting of the European Thyroid Association in Krakow on September 11, 2011, and this study is the follow-up of the special report. Objectives To present a preliminary review of potential thyroid consequences of the 2011 Fukushima nuclear reactor accident. Methods Numerous new data have been presented in Japanese, and most of them are available on the website from each research institute and/or from each municipality. The review was made using these data from the website. Results When individual radiation doses were expressed as values in more than 99% of residents, radiation doses by behavior survey in evacuation and deliberate evacuation areas were less than 10 mSv in the first 4 months, and internal radiation doses measured by whole body counters were less than 1 mSv/year. Individual thyroid radiation doses were less than 50 mSv (intervention levels) even in evacuation areas. As for health consequences, no one died and no one suffered from acute effects. The thyroid ultrasound examination is in progress and following examination of almost 40,000 children, 35% of them have nodules and/or cysts but no cancers. Conclusions Countermeasures against radiation must consider current individual measured values, although every effort must be taken to reconstruct radiation doses as precisely as possible. At present, the difference of thyroid radiation dose between Chernobyl and Fukushima appears to be due to the strict control of milk started within a week after the accident in Fukushima. Since the iodine-131 plume moved around in wide areas and for a long time, the method of thyroid protection must be reconsidered. PMID:24783014

  5. Counter-responses as organizers in adolescent analysis and therapy.

    PubMed

    Richmond, M Barrie

    2004-01-01

    The author introduces Counter-response as a phenomological term to replace theory-burdened terms like counter-transference, counter-identification, and counter-resistance. He discusses the analyst's use of self (drawing on the comparison with Winnicott's use of the object) in processing the expectable destabilizing counter-reactions that occur in working therapeutically with disturbed adolescents and their parents. Further; he discusses the counter-reaction to the patient's narrative, acting-out, and how re-enactments can serve as an organizer for understanding the patient's inner life when the analyst formulates his/her counter-response. Emphasis is placed on the therapist forming his or her own narrative with the adolescent that takes into account the evoked counter-reaction. For this purpose, the author recommends the use of a combined counter-response and metaphor-orienting perspective to acknowledge and work with the denial, illusions, reversal of perspective, and catastrophic anxieties experienced with these adolescents. The counter-response perspective permits the emergence of the disturbed adolescent's novel narrative; however, since these experiences can be destabilizing or disruptive, the author also recommends the use of a personal metaphor to anticipate the reluctance to examining, processing, and formulating the analyst's dysphoric counter-reaction. With the use of the counter-response, the analyst's therapeutic ideal is to achieve a more optimal balance between using accepted narrative theories and exploring novel enactment experiences. His swimming metaphor stratagem is designed to keep the analyst in these difficult encounters.

  6. Modular high speed counter employing edge-triggered code

    DOEpatents

    Vanstraelen, Guy F.

    1993-06-29

    A high speed modular counter (100) utilizing a novel counting method in which the first bit changes with the frequency of the driving clock, and changes in the higher order bits are initiated one clock pulse after a "0" to "1" transition of the next lower order bit. This allows all carries to be known one clock period in advance of a bit change. The present counter is modular and utilizes two types of standard counter cells. A first counter cell determines the zero bit. The second counter cell determines any other higher order bit. Additional second counter cells are added to the counter to accommodate any count length without affecting speed.

  7. Modular high speed counter employing edge-triggered code

    DOEpatents

    Vanstraelen, G.F.

    1993-06-29

    A high speed modular counter (100) utilizing a novel counting method in which the first bit changes with the frequency of the driving clock, and changes in the higher order bits are initiated one clock pulse after a 0'' to 1'' transition of the next lower order bit. This allows all carries to be known one clock period in advance of a bit change. The present counter is modular and utilizes two types of standard counter cells. A first counter cell determines the zero bit. The second counter cell determines any other higher order bit. Additional second counter cells are added to the counter to accommodate any count length without affecting speed.

  8. Multi-anode wire two dimensional proportional counter for detecting Iron-55 X-Ray Radiation

    NASA Astrophysics Data System (ADS)

    Weston, Michael William James

    Radiation detectors in many applications use small sensor areas or large tubes which only collect one-dimensional information. There are some applications that require analyzing a large area and locating specific elements such as contamination on the heat tiles of a space shuttle or features on historical artifacts. The process can be time consuming and scanning a large area in a single pass is beneficial. The use of a two dimensional multi-wire proportional counter provides a large detection window presenting positional information in a single pass. This thesis described the design and implementation of an experimental detector to evaluate a specific design intended for use as a handheld instrument. The main effort of this research was to custom build a detector for testing purposes. The aluminum chamber and all circuit boards were custom designed and built specifically for this application. Various software and programmable logic algorithms were designed to analyze the raw data in real time and attempted to determine what data was useful and what could be discarded. The research presented here provides results useful for designing an improved second generation detector in the future. With the anode wire spacing chosen and the minimal collimation of the radiation source, detected events occurred all over the detection grid at any time. The raw event data did not make determining the source position easy and further data correlation was required. An abundance of samples had multiple wire hits which were not useful because it falsely reported the source to be all over the place and at different energy levels. By narrowing down the results to only use the largest signal pairs on different axes in each event, a much more accurate analysis of where the source existed above the grid was determined. The basic principle and construction method was shown to work, however the gas selection, geometry and anode wire constructs proved to be poor. To provide a system optimized for a specific application would require detailed Monte Carlo simulations. These simulation results together with the details and techniques implemented in this thesis would provide a final instrument of much higher accuracy.

  9. Think the way to measure the Earth Radiation Budget and the Total Solar Irradiance with a small satellites constellation

    NASA Astrophysics Data System (ADS)

    Meftah, M.; Keckhut, P.; Damé, L.; Bekki, S.; Sarkissian, A.; Hauchecorne, A.

    2018-05-01

    Within the past decade, satellites constellations have become possible and practical. One of the interest to use a satellites constellation is to measure the true Earth Radiation Imbalance, which is a crucial quantity for testing climate models and for predicting the future course of global warming. This measurement presents a high interest because the 2001-2010 decade has not shown the accelerating pace of global warming that most models predict, despite the fact that the greenhouse-gas radiative forcing continues to rise. All estimates (ocean heat content and top of atmosphere) show that over the past decade the Earth radiation imbalance ranges between 0.5 to 1W-2. Up to now, the Earth radiation imbalance has not been measured directly. The only way to measure the imbalance with sufficient accuracy is to measure both the incoming solar radiations (total solar irradiance) and the outgoing terrestrial radiations (top of atmosphere outgoing longwave radiations and shortwave radiations) onboard the same satellite, and ideally, with the same instrument. The incoming solar radiations and the outgoing terrestrial radiations are of nearly equal magnitude of the order of 340.5W-2. The objective is to measure these quantities over time by using differential Sun-Earth measurements (to counter calibration errors) with an accuracy better than 0.05Wm-2 at 1σ. It is also necessary to have redundant instruments to track aging in space in order to measure during a decade and to measure the global diurnal cycle with a dozen satellites. Solar irradiance and Earth Radiation Budget (SERB) is a potential first in orbit demonstration satellite. The SERB nano-satellite aims to measure on the same platform the different components of the Earth radiation budget and the total solar irradiance. Instrumental payloads (solar radiometer and Earth radiometers) can acquire the technical maturity for the future large missions (constellation that insure global measurement cover) by flying in a CubeSat. This paper is intended to demonstrate the ability to build a low-cost satellite with a high accuracy measurement in order to have constant flow of data from space.

  10. Radiation in Yolo County

    NASA Astrophysics Data System (ADS)

    Dickie, H.; Colwell, K.

    2013-12-01

    In today's post-nuclear age, there are many man-made sources of radioactivity, in addition to the natural background we expect from cosmic and terrestrial origins. While all atoms possess unstable isotopes, there are few that are abundant enough, energetic enough, and have long enough half-lives to pose a signicant risk of ionizing radiation exposure. We hypothesize a decreasing relative radiation measurement (in detected counts per minute [CPM]) at nine locations that might pose occupational or environmental hazard: 1. A supermarket produce aisle (living tissue has high concentration of 40K) 2. A hospital (medical imaging uses X-rays and radioactive dyes) 3. The electronics section of a superstore (high voltage electronics have the potential to produce ionizing radiation) 4. An electrical transformer (similar reasons) 5. An antique store (some ceramics and glazes use radioisotopes that are now outlawed) 6. A gasoline pump (processing and terrestrial isotope contamination might leave a radioactive residue) 7. A fertilized eld (phosphate rock contains uranium and thorium, in addition to potassium) 8. A house (hopefully mild background, but potential radon contamination) 9. A school (should be radiologically neutral) We tested the hypothesis by measuring 100 minutes of counts on a self-assembled MightyOhmTM Geiger counter at each location. Our results show that contrary to the hypothesized ordering, the house was the most radiologically active. We present possible explanations for the observed radiation levels, as well as possible sources of measurement error, possible consequences of prolonged exposure to the measured levels, and suggestions for decreasing exposure and environmental impact.

  11. Response of Silicon-Based Linear Energy Transfer Spectrometers: Implication for Radiation Risk Assessment in Space Flights

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; O'Neill, P. M.

    2001-01-01

    There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed. c2001 Elsevier Science B.V. All rights reserved.

  12. Mice heterozygous for the ATM gene are more sensitive to both X-ray and heavy ion exposure than are wildtypes

    NASA Astrophysics Data System (ADS)

    Worgul, B. V.; Smilenov, L.; Brenner, D. J.; Vazquez, M.; Hall, E. J.

    Previous studies have shown that the eyes of ATM heterozygous mice exposed to low-LET radiation (X-rays) are significantly more susceptible to the development of cataracts than are those of wildtype mice. The findings, as well as others, run counter to the assumption underpinning current radiation safety guidelines, that individuals are all equally sensitive to the biological effects of radiation. A question, highly relevant to human space activities is whether or not, in similar fashion there may exist a genetic predisposition to high-LET radiation damage. Mice haplodeficient for the ATM gene and wildtypes were exposed to 325 mGy of 1 GeV/amu 56Fe ions at the AGS facility of Brookhaven National Laboratory. The fluence was equivalent to 1 ion per lens epithelial cell nuclear area. Controls consisted of irradiated wildtype as well as unirradiated wildtype and heterozygous mice. Prevalence analyses for stage 0.5-3.0 cataracts indicated that not only cataract onset but also progression were accelerated in the mice haplo-deficient for the ATM gene. The data show that heterozygosity for the ATM gene predisposes the eye to the cataractogenic influence of heavy ions and suggest that ATM heterozygotes in the human population may also be radiosensitive. This may have to be considered in the selection of individuals who will be exposed to both HZE particles and low-LET radiation as they may be predisposed to increased late normal tissue damage.

  13. Response of silicon-based linear energy transfer spectrometers: implication for radiation risk assessment in space flights.

    PubMed

    Badhwar, G D; O'Neill, P M

    2001-07-11

    There is considerable interest in developing silicon-based telescopes because of their compactness and low power requirements. Three such telescopes have been flown on board the Space Shuttle to measure the linear energy transfer spectra of trapped, galactic cosmic ray, and solar energetic particles. Dosimeters based on single silicon detectors have also been flown on the Mir orbital station. A comparison of the absorbed dose and radiation quality factors calculated from these telescopes with that estimated from measurements made with a tissue equivalent proportional counter show differences which need to be fully understood if these telescopes are to be used for astronaut radiation risk assessments. Instrument performance is complicated by a variety of factors. A Monte Carlo-based technique was developed to model the behavior of both single element detectors in a proton beam, and the performance of a two-element, wide-angle telescope, in the trapped belt proton field inside the Space Shuttle. The technique is based on: (1) radiation transport intranuclear-evaporation model that takes into account the charge and angular distribution of target fragments, (2) Landau-Vavilov distribution of energy deposition allowing for electron escape, (3) true detector geometry of the telescope, (4) coincidence and discriminator settings, (5) spacecraft shielding geometry, and (6) the external space radiation environment, including albedo protons. The value of such detailed modeling and its implications in astronaut risk assessment is addressed. c2001 Elsevier Science B.V. All rights reserved.

  14. Liquid Scintillation Counting - Packard Triple-Label Calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Torretto, P. A.

    2017-03-23

    The Radiological Measurements Laboratory (RML) maintains and operates nine Packard Liquid Scintillation Counters (LSCs). These counters were obtained through various sources and were generally purchased as 2500, 2700 or 3100 series counters. In 2004/2005 the software and firmware on the counters were upgraded. The counters are now designated as 3100 series counters running the Quantasmart software package. Thus, a single procedure can be used to calibrate and operate the Packard LSCs.

  15. AREA MONITORING OF AMBIENT DOSE RATES IN PARTS OF SOUTH-WESTERN NIGERIA USING A GPS-INTEGRATED RADIATION SURVEY METER.

    PubMed

    Okeyode, I C; Rabiu, J A; Alatise, O O; Makinde, V; Akinboro, F G; Al-Azmi, D; Mustapha, A O

    2017-04-01

    A radiation monitoring system comprising a Geiger-Muller counter connected to a smart phone via Bluetooth was used for a dose rate survey in some parts of south-western Nigeria. The smart phone has the Geographical Positioning System, which provides the navigation information and saves it along with the dose rate data. A large number of data points was obtained that shows the dose rate distribution within the region. The results show that the ambient dose rates in the region range from 60 to 520 nSv -1 and showed a bias that is attributable to the influence of geology on the ambient radiation dose in the region. The geology influence was demonstrated by superimposing the dose rate plot and the geological map of the area. The potential applications of the device in determining baseline information and in area monitoring, e.g. for lost or abandoned sources, radioactive materials stockpiles, etc., were discussed in the article, particularly against the background of Nigeria's plan to develop its nuclear power program. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Radiation dosimetry measurements during U.S. Space Shuttle missions with the RME-III.

    PubMed

    Golightly, M J; Hardy, K; Quam, W

    1994-01-01

    Time-resolved radiation dosimetry measurements inside the crew compartment have been made during recent Shuttle missions with the U.S. Air Force Radiation Monitoring Equipment-III (RME-III), a portable battery-powered four-channel tissue equivalent proportional counter. Results from the first six missions are presented and discussed. Half of the missions had orbital inclinations of 28.5 degrees with the remainder at inclinations of 57 degrees or greater; altitudes ranged from 300 to 600 km. The determined dose equivalent rates ranged from 70 to 5300 microSv/day. The RME-III measurements are in good agreement with other dosimetry measurements made aboard the vehicles. Measurements indicate that medium- and high-LET particles contribute less than 2% of the particle fluence for all missions, but up to 50% of the dose equivalent, depending on the spacecraft's altitude and orbital inclination. Isocontours of fluence, dose and dose equivalent rate have been developed from measurements made during the STS-28 mission. The drift rate of the South Atlantic Anomaly is estimated to be 0.49 degrees W/yr and 0.12 degrees N/yr. The calculated trapped proton and GCR dose for the STS-28 mission was significantly lower than the measured values.

  17. Seasonality of tuberculosis in Israel, 2001-2011.

    PubMed

    Margalit, I; Block, C; Mor, Z

    2016-12-01

    Several studies have suggested that the incidence of tuberculosis (TB) varies with the seasons. To determine the seasonality of TB in Israel and to explore possible associations with climatic variables. Laboratory-confirmed TB cases reported between 2001 and 2011 in individuals resident in Israel for at least 1 year before diagnosis were included in the study. Climatic variables included average temperature and average ultraviolet radiation. The mean serum 25-hydroxyvitamin D level of the population was also recorded. Of all 2653 TB cases, incidence peaked during spring (n = 712) and reached its nadir during the fall (n = 577), with a case proportion amplitude (CPA) of 5.1% (P = 0.036). Individuals born in the Horn of Africa exhibited a CPA of 9.5% (P = 0.077). Mean population 25-hydroxyvitamin D level was significantly correlated with the seasonal pattern of the disease. Southern Israel had the highest global radiation and, counter-instinctively, the highest TB incidence. TB exhibited a seasonal tendency in Israel, with the spring peak/fall nadir pattern found elsewhere. Vitamin D is suspected to be an explanatory variable for this seasonal phenomenon. The finding that the highest incidence is in the area receiving the highest global radiation suggests population-related vulnerability to vitamin D deficiency.

  18. X-Ray Diffraction Study of the Internal Structure of Supercooled Water

    NASA Technical Reports Server (NTRS)

    Dorsch, Robert G.; Boyd, Bemrose

    1951-01-01

    A Bragg X-ray spectrometer equipped with a volume-sensitive Geiger counter and Soller slits and employing filtered molybdenum Ka radiation was used to obtain a set of diffracted intensity curves as a Punction of angle for supercooled water. Diffracted intensity curves in the temperature region of 21 to -16 C were obtained. The minimum between the two main diffraction peaks deepened continuously with lowering temperature, indicating a gradual change in the internal structure of the water. No discontinuity in this trend was noted at the melting point. The internal structure of supercooled water was concluded to become progressively more ice-like as the temperature is lowered.

  19. Dupoly process for treatment of depleted uranium and production of beneficial end products

    DOEpatents

    Kalb, Paul D.; Adams, Jay W.; Lageraaen, Paul R.; Cooley, Carl R.

    2000-02-29

    The present invention provides a process of encapsulating depleted uranium by forming a homogenous mixture of depleted uranium and molten virgin or recycled thermoplastic polymer into desired shapes. Separate streams of depleted uranium and virgin or recycled thermoplastic polymer are simultaneously subjected to heating and mixing conditions. The heating and mixing conditions are provided by a thermokinetic mixer, continuous mixer or an extruder and preferably by a thermokinetic mixer or continuous mixer followed by an extruder. The resulting DUPoly shapes can be molded into radiation shielding material or can be used as counter weights for use in airplanes, helicopters, ships, missiles, armor or projectiles.

  20. Radiation pressure injection in laser-wakefield acceleration

    NASA Astrophysics Data System (ADS)

    Liu, Y. L.; Kuramitsu, Y.; Isayama, S.; Chen, S. H.

    2018-01-01

    We investigated the injection of electrons in laser-wakefield acceleration induced by a self-modulated laser pulse by a two dimensional particle-in-cell simulation. The localized electric fields and magnetic fields are excited by the counter-streaming flows on the surface of the ion bubble, owing to the Weibel or two stream like instability. The electrons are injected into the ion bubble from the sides of it and then accelerated by the wakefield. Contrary to the conventional wave breaking model, the injection of monoenergetic electrons are mainly caused by the electromagnetic process. A simple model was proposed to address the instability, and the growth rate was verified numerically and theoretically.

  1. Neutron activation analysis system

    DOEpatents

    Taylor, M.C.; Rhodes, J.R.

    1973-12-25

    A neutron activation analysis system for monitoring a generally fluid media, such as slurries, solutions, and fluidized powders, including two separate conduit loops for circulating fluid samples within the range of radiation sources and detectors is described. Associated with the first loop is a neutron source that emits s high flux of slow and thermal neutrons. The second loop employs a fast neutron source, the flux from which is substantially free of thermal neutrons. Adjacent to both loops are gamma counters for spectrographic determination of the fluid constituents. Other gsmma sources and detectors are arranged across a portion of each loop for deterMining the fluid density. (Official Gazette)

  2. Search for Neutrinos from the Sun

    DOE R&D Accomplishments Database

    Davis, Raymond Jr.

    1968-09-01

    A solar neutrino detection system has been built to observe the neutrino radiation from the sun. The detector uses 3,900,000 liters of tetrachloroethylene as the neutrino capturing medium. Argon is removed from the liquid by sweeping with helium gas, and counted in a small low level proportional counter. The recovery efficiency of the system was tested with Ar{sup 36} by the isotope dilution method, and also with Ar{sup 37} produced in the liquid by fast neutrons. These tests demonstrate that Ar{sup 37} produced in the liquid by neutrino capture can be removed with a 95 percent efficiency by the procedure used.

  3. Neutron skyshine measurements at Fermilab.

    PubMed

    Cossairt, J D; Coulson, L V

    1985-02-01

    Neutron skyshine has been a significant source of environmental radiation exposure at many high-energy proton accelerators. A particularly troublesome source of skyshine neutrons has existed at Fermilab during operation of the 400-GeV high-energy physics program. This paper reports on several measurements of this source made with a DePangher precision long counter at large distances. The spatial distribution of the neutron skyshine can approximately be described as an inverse square law dependence multiplied by an exponential with an approximate attenuation length of 1200 +/- 300 m. The absolute magnitude of the distributions can be matched directly to the conventionally measured absorbed dose distribution near the source.

  4. Counter design influences the privacy of patients in health care.

    PubMed

    Mobach, Mark P

    2009-03-01

    A re-furnishing of counter areas in primary health care was used to assess patient privacy and its influences on the nature of conversations in a controlled experiment. Patients in two community-based pharmacies in the Netherlands were assigned to enclosed counters and a queue at distance, or to counters that exposed patients mutually and a closer queue. Patients assigned to counters with reduced sight were more satisfied with the privacy than patients at visually exposed counters. However, in comparison with visually exposed pharmacy counters, conversations of patients at enclosed counters could still be overheard and did not have different conversations to other patients. Architectural design of health-care institutions has potential to positively influence perceived patient privacy in areas in where multiple patient-staff communications routinely occur and where patient privacy is an important issue, but enclosed counters with a queue at distance do not prevent incidental disclosure of individually identifiable health information.

  5. Performing a local barrier operation

    DOEpatents

    Archer, Charles J; Blocksome, Michael A; Ratterman, Joseph D; Smith, Brian E

    2014-03-04

    Performing a local barrier operation with parallel tasks executing on a compute node including, for each task: retrieving a present value of a counter; calculating, in dependence upon the present value of the counter and a total number of tasks performing the local barrier operation, a base value, the base value representing the counter's value prior to any task joining the local barrier; calculating, in dependence upon the base value and the total number of tasks performing the local barrier operation, a target value of the counter, the target value representing the counter's value when all tasks have joined the local barrier; joining the local barrier, including atomically incrementing the value of the counter; and repetitively, until the present value of the counter is no less than the target value of the counter: retrieving the present value of the counter and determining whether the present value equals the target value.

  6. Performing a local barrier operation

    DOEpatents

    Archer, Charles J; Blocksome, Michael A; Ratterman, Joseph D; Smith, Brian E

    2014-03-04

    Performing a local barrier operation with parallel tasks executing on a compute node including, for each task: retrieving a present value of a counter; calculating, in dependence upon the present value of the counter and a total number of tasks performing the local barrier operation, a base value of the counter, the base value representing the counter's value prior to any task joining the local barrier; calculating, in dependence upon the base value and the total number of tasks performing the local barrier operation, a target value, the target value representing the counter's value when all tasks have joined the local barrier; joining the local barrier, including atomically incrementing the value of the counter; and repetitively, until the present value of the counter is no less than the target value of the counter: retrieving the present value of the counter and determining whether the present value equals the target value.

  7. Radiation measurements at the campus of Fukushima Medical University through the 2011 off the Pacific Coast of Tohoku earthquake and subsequent nuclear power plant crisis.

    PubMed

    Kobayashi, Tsuneo

    2011-01-01

    An earthquake, Tohoku region Pacific Coast earthquake, occurred on the 11th of March, 2011, and subsequent Fukushima nuclear power plant accidents have been stirring natural radiation around the author's office in Fukushima Medical University (FMU). FMU is located in Fukushima city, and is 57 km (35 miles) away from northwest of the Fukushima Daiichi nuclear power plant. This paper presents three types of radiation survey undertaken through the unprecedented accidents at the campus and the hospital of FMU. First, a group of interested people immediately began radiation surveillance; the group members were assembled from the faculty members of " Life Sciences and Social Medicine" and " Human and Natural Sciences." Second, the present author, regardless of the earthquake, had serially observed natural radiations such as gamma radiation in air with NaI scintillation counter, atmospheric radon with Lucas cell, and second cosmic rays with NaI scintillation. Gamma radiation indicated most drastic change, i.e., peak value (9.3 times usual level) appeared on March 16, and decreased to 1.7 times usual level after two months. A nonlinear least squares regression to this decreasing data gave short half-life of 3.6 days and long half-life of 181 days. These two apparent half-lives are attributed to two groups of radioisotopes, i.e., short half-life one of I-131 and long half-life ones of Cs-134, Cs-137 and Sr-90. Also, atmospheric radon concentration became high since a stop of ventilation, while second cosmic rays did not show any response. Third, late April, 2011, a team of radiation dosimetry under the direct control of Dean, School of Medicine, was established for the continuation of radiation survey in the campus and the hospital of Fukushima Medical University.

  8. Limited Internal Radiation Exposure Associated with Resettlements to a Radiation-Contaminated Homeland after the Fukushima Daiichi Nuclear Disaster

    PubMed Central

    Tsubokura, Masaharu; Kato, Shigeaki; Nihei, Masahiko; Sakuma, Yu; Furutani, Tomoyuki; Uehara, Keisuke; Sugimoto, Amina; Nomura, Shuhei; Hayano, Ryugo; Kami, Masahiro; Watanobe, Hajime; Endo, Yukou

    2013-01-01

    Resettlement to their radiation-contaminated hometown could be an option for people displaced at the time of a nuclear disaster; however, little information is available on the safety implications of these resettlement programs. Kawauchi village, located 12–30 km southwest of the Fukushima Daiichi nuclear power plant, was one of the 11 municipalities where mandatory evacuation was ordered by the central government. This village was also the first municipality to organize the return of the villagers. To assess the validity of the Kawauchi villagers’ resettlement program, the levels of internal Cesium (Cs) exposures were comparatively measured in returnees, commuters, and non-returnees among the Kawauchi villagers using a whole body counter. Of 149 individuals, 5 villagers had traceable levels of Cs exposure; the median detected level was 333 Bq/body (range, 309–1050 Bq/kg), and 5.3 Bq/kg (range, 5.1–18.2 Bq/kg). Median annual effective doses of villagers with traceable Cs were 1.1 x 10-2 mSv/y (range, 1.0 x 10-2-4.1 x 10-2 mSv/y). Although returnees had higher chances of consuming locally produced vegetables, Cochran-Mantel-Haenszel test showed that their level of internal radiation exposure was not significantly higher than that in the other 2 groups (p=0.643). The present findings in Kawauchi village imply that it is possible to maintain internal radiation exposure at very low levels even in a highly radiation-contaminated region at the time of a nuclear disaster. Moreover, the risks for internal radiation exposure could be limited with a strict food control intervention after resettlement to the radiation-contaminated village. It is crucial to establish an adequate number of radio-contaminated testing sites within the village, to provide immediate test result feedback to the villagers, and to provide education regarding the importance of re-testing in reducing the risk of high internal radiation exposure. PMID:24312602

  9. Limited internal radiation exposure associated with resettlements to a radiation-contaminated homeland after the Fukushima Daiichi nuclear disaster.

    PubMed

    Tsubokura, Masaharu; Kato, Shigeaki; Nihei, Masahiko; Sakuma, Yu; Furutani, Tomoyuki; Uehara, Keisuke; Sugimoto, Amina; Nomura, Shuhei; Hayano, Ryugo; Kami, Masahiro; Watanobe, Hajime; Endo, Yukou

    2013-01-01

    Resettlement to their radiation-contaminated hometown could be an option for people displaced at the time of a nuclear disaster; however, little information is available on the safety implications of these resettlement programs. Kawauchi village, located 12-30 km southwest of the Fukushima Daiichi nuclear power plant, was one of the 11 municipalities where mandatory evacuation was ordered by the central government. This village was also the first municipality to organize the return of the villagers. To assess the validity of the Kawauchi villagers' resettlement program, the levels of internal Cesium (Cs) exposures were comparatively measured in returnees, commuters, and non-returnees among the Kawauchi villagers using a whole body counter. Of 149 individuals, 5 villagers had traceable levels of Cs exposure; the median detected level was 333 Bq/body (range, 309-1050 Bq/kg), and 5.3 Bq/kg (range, 5.1-18.2 Bq/kg). Median annual effective doses of villagers with traceable Cs were 1.1 x 10(-2) mSv/y (range, 1.0 x 10(-2)-4.1 x 10(-2) mSv/y). Although returnees had higher chances of consuming locally produced vegetables, Cochran-Mantel-Haenszel test showed that their level of internal radiation exposure was not significantly higher than that in the other 2 groups (p=0.643). The present findings in Kawauchi village imply that it is possible to maintain internal radiation exposure at very low levels even in a highly radiation-contaminated region at the time of a nuclear disaster. Moreover, the risks for internal radiation exposure could be limited with a strict food control intervention after resettlement to the radiation-contaminated village. It is crucial to establish an adequate number of radio-contaminated testing sites within the village, to provide immediate test result feedback to the villagers, and to provide education regarding the importance of re-testing in reducing the risk of high internal radiation exposure.

  10. Irradiating of Bulk Soybeans: Influence on Their Functional and Sensory Properties for Soyfood Processing

    NASA Technical Reports Server (NTRS)

    Chia, Chiew-Ling; Wilson, Lester A.; Boylston, Terri; Perchonok, Michele; French, Stephen

    2006-01-01

    Soybeans were chosen for lunar and planetary missions, where soybeans will be supplied in bulk or grown locally, due to their nutritive value and ability to produce oil and protein for further food applications. However, soybeans must be processed into foods prior to consumption. Radiation that soybeans would be exposed to during bulk storage prior to and during a Mars mission may influence their germination and functional properties. The influence of radiation includes the affect of surface pasteurization to ensure the astronauts safety from food-borne illnesses (HACCP, CCP), and the affect of the amount of radiation the soybeans receive during a Mars mission. Decreases in the amount of natural antioxidants free radical formation, and oxidation-induced changes in the soybean will influence the nutritional value, texture, color, and aroma of soyfoods. The objective of this study was to determine the influence of pasteurization and sterilization surface radiation on whole soybeans using gamma and electron beam radiation. The influence of 0, 1, 5, 10, and 30kGy on microbial load, germination rate, ease of processing, and quality of soymilk and tofu were determined. Surface radiation of whole dry soybeans using electron beam or gamma rays from 1-30kGy did provide microbial safety for the astronauts. However, the lower dose levels had surviving yeasts and molds. These doses caused oxidative changes that resulted in soymilk and tofu with rancid aromas. GC-MS of the aroma compounds using SPME Headspace confirmed the presence of lipid oxidation compounds. Soybean germination ability was reduced as radiation dosage increased. While lower doses may reduce these problems, the ability to insure microbial safety of bulk soybeans will be lost. Counter measures could include vacuum packaging, nitrogen flushing, added antioxidants, and radiating under freezing conditions. Doses below 1kGy need to be investigated further to determine the influence of the radiation encountered during Mars missions.

  11. Sign-And-Magnitude Up/Down Counter

    NASA Technical Reports Server (NTRS)

    Cole, Steven W.

    1991-01-01

    Magnitude-and-sign counter includes conventional up/down counter for magnitude part and special additional circuitry for sign part. Negative numbers indicated more directly. Counter implemented by programming erasable programmable logic device (EPLD) or programmable logic array (PLA). Used in place of conventional up/down counter to provide sign and magnitude values directly to other circuits.

  12. Low latency counter event indication

    DOEpatents

    Gara, Alan G [Mount Kisco, NY; Salapura, Valentina [Chappaqua, NY

    2008-09-16

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  13. Low latency counter event indication

    DOEpatents

    Gara, Alan G.; Salapura, Valentina

    2010-08-24

    A hybrid counter array device for counting events with interrupt indication includes a first counter portion comprising N counter devices, each for counting signals representing event occurrences and providing a first count value representing lower order bits. An overflow bit device associated with each respective counter device is additionally set in response to an overflow condition. The hybrid counter array includes a second counter portion comprising a memory array device having N addressable memory locations in correspondence with the N counter devices, each addressable memory location for storing a second count value representing higher order bits. An operatively coupled control device monitors each associated overflow bit device and initiates incrementing a second count value stored at a corresponding memory location in response to a respective overflow bit being set. The incremented second count value is compared to an interrupt threshold value stored in a threshold register, and, when the second counter value is equal to the interrupt threshold value, a corresponding "interrupt arm" bit is set to enable a fast interrupt indication. On a subsequent roll-over of the lower bits of that counter, the interrupt will be fired.

  14. Chromosome aberrations in the blood lymphocytes of astronauts after space flight

    NASA Technical Reports Server (NTRS)

    George, K.; Durante, M.; Wu, H.; Willingham, V.; Badhwar, G.; Cucinotta, F. A.

    2001-01-01

    Cytogenetic analysis of the lymphocytes of astronauts provides a direct measurement of space radiation damage in vivo, which takes into account individual radiosensitivity and considers the influence of microgravity and other stress conditions. Chromosome exchanges were measured in the blood lymphocytes of eight crew members after their respective space missions, using fluorescence in situ hybridization (FISH) with chromosome painting probes. Significant increases in aberrations were observed after the long-duration missions. The in vivo dose was derived from the frequencies of translocations and total exchanges using calibration curves determined before flight, and the RBE was estimated by comparison with individually measured physical absorbed doses. The values for average RBE were compared to the average quality factor (Q) from direct measurements of the lineal energy spectra using a tissue-equivalent proportional counter (TEPC) and radiation transport codes. The ratio of aberrations identified as complex was slightly higher after flight, which is thought to be an indication of exposure to high-LET radiation. To determine whether the frequency of complex aberrations measured in metaphase spreads after exposure to high-LET radiation was influenced by a cell cycle delay, chromosome damage was analyzed in prematurely condensed chromosome samples collected from two crew members before and after a short-duration mission. The frequency of complex exchanges after flight was higher in prematurely condensed chromosomes than in metaphase cells for one crew member.

  15. Theoretical investigation of the ultra-intense laser interaction with plasma mirrors in radiation pressure dominant regime

    NASA Astrophysics Data System (ADS)

    Sonia, Krishna Kumar; Maheshwari, K. P.; Jaiman, N. K.

    2017-05-01

    At laser intensity in the range ~ 1022 -1023W/cm2, the radiation pressure starts to play a key role in the interaction of an intense electromagnetic wave with a dense plasma foil. Depending upon the incident laser intensity, polarization of the incident beam and also on the density of the thin plasma layer the mirror motion may be assumed to be uniform, accelerated, or oscillatory. A solid dense plasma slab, accelerated in the radiation pressure dominant (RPD) regime, can efficiently reflect a counter-propagating relativistically strong source pulse consisting of up-shifted frequency and high harmonics. In this RPD regime we present our numerical results for the frequency and brightness of the reflected radiation from a uniformly moving plasma mirror. Our numerical results show that for the appropriate laser and plasma parameters in the case 2γ < {({n}e{λ }s3)}1/6 there are approximately 8.03 × 1042 photons / (mm2 - mrad2 - sec.-0.1% bandwidth) in the energy range ~ 10keV. In the case when 2γ > {({n}e{λ }s3)}1/6 for the same parameters and ad = 300, λd = 0.8 μm, the brightness is found to be 3.27 × 1034 photons / (mm2 - mrad2 - sec. - 0.1% bandwidth) in the energy range ~100 keV.

  16. Chromosome aberrations in the blood lymphocytes of astronauts after space flight.

    PubMed

    George, K; Durante, M; Wu, H; Willingham, V; Badhwar, G; Cucinotta, F A

    2001-12-01

    Cytogenetic analysis of the lymphocytes of astronauts provides a direct measurement of space radiation damage in vivo, which takes into account individual radiosensitivity and considers the influence of microgravity and other stress conditions. Chromosome exchanges were measured in the blood lymphocytes of eight crew members after their respective space missions, using fluorescence in situ hybridization (FISH) with chromosome painting probes. Significant increases in aberrations were observed after the long-duration missions. The in vivo dose was derived from the frequencies of translocations and total exchanges using calibration curves determined before flight, and the RBE was estimated by comparison with individually measured physical absorbed doses. The values for average RBE were compared to the average quality factor (Q) from direct measurements of the lineal energy spectra using a tissue-equivalent proportional counter (TEPC) and radiation transport codes. The ratio of aberrations identified as complex was slightly higher after flight, which is thought to be an indication of exposure to high-LET radiation. To determine whether the frequency of complex aberrations measured in metaphase spreads after exposure to high-LET radiation was influenced by a cell cycle delay, chromosome damage was analyzed in prematurely condensed chromosome samples collected from two crew members before and after a short-duration mission. The frequency of complex exchanges after flight was higher in prematurely condensed chromosomes than in metaphase cells for one crew member.

  17. Light escape cones in local reference frames of Kerr-de Sitter black hole spacetimes and related black hole shadows

    NASA Astrophysics Data System (ADS)

    Stuchlík, Zdeněk; Charbulák, Daniel; Schee, Jan

    2018-03-01

    We construct the light escape cones of isotropic spot sources of radiation residing in special classes of reference frames in the Kerr-de Sitter (KdS) black hole spacetimes, namely in the fundamental class of `non-geodesic' locally non-rotating reference frames (LNRFs), and two classes of `geodesic' frames, the radial geodesic frames (RGFs), both falling and escaping, and the frames related to the circular geodesic orbits (CGFs). We compare the cones constructed in a given position for the LNRFs, RGFs, and CGFs. We have shown that the photons locally counter-rotating relative to LNRFs with positive impact parameter and negative covariant energy are confined to the ergosphere region. Finally, we demonstrate that the light escaping cones govern the shadows of black holes located in front of a radiating screen, as seen by the observers in the considered frames. For shadows related to distant static observers the LNRFs are relevant.

  18. Cherenkov radiation imaging of beta emitters: in vitro and in vivo results

    NASA Astrophysics Data System (ADS)

    Spinelli, Antonello E.; Boschi, Federico; D'Ambrosio, Daniela; Calderan, Laura; Marengo, Mario; Fenzi, Alberto; Menegazzi, Marta; Sbarbati, Andrea; Del Vecchio, Antonella; Calandrino, Riccardo

    2011-08-01

    The main purpose of this work was to investigate both in vitro and in vivo Cherenkov radiation (CR) emission coming from 18F and 32P. The main difference between 18F and 32P is mainly the number of the emitted light photons, more precisely the same activity of 32P emits more CR photons with respect to 18F. In vitro results obtained by comparing beta counter measurements with photons average radiance showed that Cherenkov luminescence imaging (CLI) allows quantitative tracer activity measurements. In order to investigate in vivo the CLI approach, we studied an experimental xenograft tumor model of mammary carcinoma (BB1 tumor cells). Cherenkov in vivo dynamic whole body images of tumor bearing mice were acquired and the tumor tissue time activity curves reflected the well-known physiological accumulation of 18F-FDG in malignant tissues with respect to normal tissues. The results presented here show that it is possible to use conventional optical imaging devices for in vitro or in vivo study of beta emitters.

  19. The PAMELA experiment on satellite and its capability in cosmic rays measurements

    NASA Astrophysics Data System (ADS)

    Adriani, O.; Ambriola, M.; Barbarino, G.; Barbier, L. M.; Bartalucci, S.; Bazilevskaja, G.; Bellotti, R.; Bertazzoni, S.; Bidoli, V.; Boezio, M.; Bogomolov, E.; Bonechi, L.; Bonvicini, V.; Boscherini, M.; Bravar, U.; Cafagna, F.; Campana, D.; Carlson, P.; Casolino, M.; Castellano, M.; Castellini, G.; Christian, E. R.; Ciacio, F.; Circella, M.; D'Alessandro, R.; De Marzo, C. N.; De Pascale, M. P.; Finetti, N.; Furano, G.; Gabbanini, A.; Galper, A. M.; Giglietto, N.; Grandi, M.; Grigorjeva, A.; Guarino, F.; Hof, M.; Koldashov, S. V.; Korotkov, M. G.; Krizmanic, J. F.; Krutkov, S.; Lund, J.; Marangelli, B.; Marino, L.; Menn, W.; Mikhailov, V. V.; Mirizzi, N.; Mitchell, J. W.; Mocchiutti, E.; Moiseev, A. A.; Morselli, A.; Mukhametshin, R.; Ormes, J. F.; Osteria, G.; Ozerov, J. V.; Papini, P.; Pearce, M.; Perego, A.; Piccardi, S.; Picozza, P.; Ricci, M.; Salsano, A.; Schiavon, P.; Scian, G.; Simon, M.; Sparvoli, R.; Spataro, B.; Spillantini, P.; Spinelli, P.; Stephens, S. A.; Stochaj, S. J.; Stozhkov, Y.; Straulino, S.; Streitmatter, R. E.; Taccetti, F.; Tesi, M.; Vacchi, A.; Vannuccini, E.; Vasiljev, G.; Vignoli, V.; Voronov, S. A.; Yurkin, Y.; Zampa, G.; Zampa, N.

    2002-02-01

    The PAMELA& equipment will be assembled in 2001 and installed on board the Russian satellite Resurs. PAMELA is conceived mainly to study the antiproton and positron fluxes in cosmic rays up to high energy (190GeV for p¯ and 270GeV for e+) and to search antinuclei, up to 30GeV/n, with a sensitivity of 10-7 in the He/He ratio. The PAMELA telescope consists of: a magnetic spectrometer made up of a permanent magnet system equipped with double sided microstrip silicon detectors; a transition radiation detector made up of active layers of proportional straw tubes interleaved with carbon fibre radiators; and a silicon-tungsten imaging calorimeter made up of layers of tungsten absorbers and silicon detector planes. A time-of-flight system and anti-coincidence counters complete the PAMELA equipment. In the past years, tests have been done on each subdetector of PAMELA; the main results are presented and their implications on the anti-particles identification capability in cosmic rays are discussed here.

  20. Combined Ceria Reduction and Methane Reforming in a Solar-Driven Particle-Transport Reactor.

    PubMed

    Welte, Michael; Warren, Kent; Scheffe, Jonathan R; Steinfeld, Aldo

    2017-09-20

    We report on the experimental performance of a solar aerosol reactor for carrying out the combined thermochemical reduction of CeO 2 and reforming of CH 4 using concentrated radiation as the source of process heat. The 2 kW th solar reactor prototype utilizes a cavity receiver enclosing a vertical Al 2 O 3 tube which contains a downward gravity-driven particle flow of ceria particles, either co-current or counter-current to a CH 4 flow. Experimentation under a peak radiative flux of 2264 suns yielded methane conversions up to 89% at 1300 °C for residence times under 1 s. The maximum extent of ceria reduction, given by the nonstoichiometry δ (CeO 2-δ ), was 0.25. The solar-to-fuel energy conversion efficiency reached 12%. The syngas produced had a H 2 :CO molar ratio of 2, and its calorific value was solar-upgraded by 24% over that of the CH 4 reformed.

  1. Combined Ceria Reduction and Methane Reforming in a Solar-Driven Particle-Transport Reactor

    PubMed Central

    2017-01-01

    We report on the experimental performance of a solar aerosol reactor for carrying out the combined thermochemical reduction of CeO2 and reforming of CH4 using concentrated radiation as the source of process heat. The 2 kWth solar reactor prototype utilizes a cavity receiver enclosing a vertical Al2O3 tube which contains a downward gravity-driven particle flow of ceria particles, either co-current or counter-current to a CH4 flow. Experimentation under a peak radiative flux of 2264 suns yielded methane conversions up to 89% at 1300 °C for residence times under 1 s. The maximum extent of ceria reduction, given by the nonstoichiometry δ (CeO2−δ), was 0.25. The solar-to-fuel energy conversion efficiency reached 12%. The syngas produced had a H2:CO molar ratio of 2, and its calorific value was solar-upgraded by 24% over that of the CH4 reformed. PMID:28966440

  2. A study of radioactivity in modern stream gravels and its possible application as a prospecting method

    USGS Publications Warehouse

    Chew, Randall T.

    1955-01-01

    Traverses along some streams of the Colorado Plateau in areas known to contain minable uranium deposits show that anomalous radiation in the stream gravels can be detected with a suitable counter downstream from the deposits. The amount of radiation is influenced by the size of the uranium deposit, the size of the drainage area of the stream, the grain size of the sediments, and the lithology of the rocks over which the stream flows. The spacing of the stations where readings are taken is controlled by the size of the stream, and special readings are also taken directly downstream from important tributaries. An anomaly is empirically defined as a 10 percent rise over background. Radioactive material from large uranium deposits has been detected as much as 1 mile downstream. Radioactive material from smaller deposits is detachable over shorter distances. The method is slow but appears to be a useful prospecting tool under restricted conditions.

  3. Efficient conversion of 3He(n,tp) and 10B(n, α7Li) reaction energies into far-ultraviolet radiation by noble gas excimers

    NASA Astrophysics Data System (ADS)

    Hughes, Patrick P.; Coplan, Michael A.; Thompson, Alan K.; Vest, Robert E.; Clark, Charles W.

    2011-03-01

    Previous work showed that the 3He(n , tp) reaction in a cell of 3He at atmospheric pressure generated tens of far-ultraviolet (FUV) photons per reacted neutron. Here we report amplification of that signal by factors of 1000 when noble gases are added to the cell. Calibrated filter-detector measurements show that this large signal is due to noble-gas excimer emissions, and that the nuclear reaction energy is converted to FUV radiation with efficiencies of up to 30 % . Our results have been placed on an absolute scale through calibrations at the NIST SURF III Synchrotron and Center for Neutron Research. We have also seen large neutron-induced FUV signals when the 3He gas in our system is replaced with a 10B film target; an experiment on substituting 3He with BF3 is underway. Our results suggest possibilities for high-efficiency, non-3He neutron detectors as an alternative to existing proportional counters.

  4. Measurement of the photoneutron flux density distribution from cylindrical targets

    NASA Astrophysics Data System (ADS)

    Golovkov, V. M.; Basina, T. N.; Yakovlev, M. R.

    1989-09-01

    Measurements are performed of the density of photoneutron fluxes from cylindrical targets of2H2O (diameter 64 and height 86 mm), Be (outer diameter 70, inner diameter 40, height 100mm), and238U (diameter 44.5 mm, height 50 mm) under the action of braking radiation from electrons with energies of 4 to 8 MeV in order to determine the effect of target form and orientation relative to the detector upon the recorded photoneutron level. The fluxes were measured by an “all-wave” neutron detector based on an SNM-11 counter in a paraffin retarder at an angle of 90‡ to the axis of the braking radiation beam for various target orientations relative to the detector. Measurement results are compared to calculations. Photoneutron fluxes from heavy water and beryllium targets of the indicated dimensions were also measured for angles of 90, 135, and 167‡. An isotropic nature was noted in the photoneutron fluxes from both targets.

  5. Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

    NASA Technical Reports Server (NTRS)

    Lheureux, J.; Fan, C. Y.; Mainardi, R.; Gloeckler, G.

    1974-01-01

    A 6500 sq cm-ster cosmic-ray detector consisting of 12 gas counter trays sandwiched between two large-area circular scintillation counters was flown from Palestine, Texas in November 1972 to study the composition of primary particles greater than 1.5 GeV/nucleon in the charge range from 3 to 30. For each analyzed event, the particle trajectory was recorded, using four 20-wire proportional counter trays. Also recorded were the energy loss in each of the solid counters and the dE/dx losses in each of the 12 gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

  6. Chemical abundances of cosmic rays greater than 4.5 GV measured with a large area proportional counter-scintillation counter stack

    NASA Technical Reports Server (NTRS)

    Lheureux, J.; Fan, C. Y.; Gloeckler, G.; Mainardi, R.

    1973-01-01

    A 6500 sq cm-ster cosmic ray detector consisting of twelve gas counter trays sandwiched between two large area circular scintillation counters was flown from Palestine, Texas in November of 1972 to study the composition of primary particles 1.5 GeV/nucleon in the charge range 3 to 30. For each analyzed event, a recording was made of (1) the particle trajectory using four 20 wire proportional counter trays, (2) the energy loss in each of the solid counters, and (3) the dE/dx losses in each of the twelve gas counters. The large dynamic range of the detector is established by operating six of the gas counters in the ionization mode. A description of the instrument and some preliminary results are given.

  7. Multithreading in vector processors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evangelinos, Constantinos; Kim, Changhoan; Nair, Ravi

    In one embodiment, a system includes a processor having a vector processing mode and a multithreading mode. The processor is configured to operate on one thread per cycle in the multithreading mode. The processor includes a program counter register having a plurality of program counters, and the program counter register is vectorized. Each program counter in the program counter register represents a distinct corresponding thread of a plurality of threads. The processor is configured to execute the plurality of threads by activating the plurality of program counters in a round robin cycle.

  8. Hardware support for software controlled fast multiplexing of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W

    2013-10-01

    Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.

  9. Hardware support for software controlled fast multiplexing of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W.

    2013-01-01

    Performance counters may be operable to collect one or more counts of one or more selected activities, and registers may be operable to store a set of performance counter configurations. A state machine may be operable to automatically select a register from the registers for reconfiguring the one or more performance counters in response to receiving a first signal. The state machine may be further operable to reconfigure the one or more performance counters based on a configuration specified in the selected register. The state machine yet further may be operable to copy data in selected one or more of the performance counters to a memory location, or to copy data from the memory location to the counters, in response to receiving a second signal. The state machine may be operable to store or restore the counter values and state machine configuration in response to a context switch event.

  10. Tobacco counter-advertising: a review of the literature and a conceptual model for understanding effects.

    PubMed

    Agostinelli, Gina; Grube, Joel W

    2003-01-01

    The tobacco counter-advertising literature is reviewed as it relates to basic process questions concerning what makes counter-advertisements effective. Limitations in addressing (a) counter-advertisement content and the psychological mediators targeted, (b) counter-advertisement style and the affective reactions targeted, (c) prior smoking experience, and (d) other audience factors are enumerated. A theoretical model based on alcohol advertising research is presented to address those limitations. The model addresses the practical research question of predicting when tobacco counter-advertising will work by examining the independent influence of each of these enumerated factors, as well as how these factors operate in concert, qualifying each other. The model also addresses the process question of explaining how counter-advertising works by identifying affective and cognitive processes as mediators. By understanding the processes that underlie the qualified findings, one can better advise the designers of tobacco counter-advertisements how to be more effective.

  11. The Concentration Of Tritium In Urine And Internal Radiation Dose Estimation Of PTNBR Radiation Workers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tjahaja, Poppy Intan; Sukmabuana, Putu; Aisyah, Neneng Nur

    2010-12-23

    The operation of Triga 2000 reactor in Nuclear Technology Center for Materials and Radiometry (PTNBR BATAN) normally produce tritium radionuclide which is the activation product of deuterium atom in reactor primary cooling water. According to previous monitoring, tritium was detected with the concentration of 8.236{+-}0.677 kBq/L and 1.704{+-}0.046 Bq/L in the primary cooling water and in reactor hall air, respectively. The tritium in reactor hall air chronically can be inhaled by the workers. In this research, tritium content in radiation workers' urine was determined to estimate the internal radiation doses received by the workers. About 50-100 mL of urine samplesmore » were collected from 48 PTNBR workers that is classified as 24 radiation workers and 24 administration staffs as a control. Urine samples of 25 mL were then prepared by active charcoal and KMnO{sub 4} addition and followed with complete distillation. The 2 mL of distillate was added with 13 mL scintillator, shaked vigorously and remained in cool and dark condition for about 24 hours. The tritium in the samples was then measured using liquid scintillation counter (LSC) for 1 hour. From the measurement results it was obtained that the tritium concentration in the urine of radiation workers were in the range of not detected and 5.191 Bq/mL, whereas in the administration staffs the concentration were between not detected and 4.607 Bq/mL. Internally radiation doses were calculated using the tritium concentration data, and it was found the averages about 0.602 {mu}Sv/year and 0.532 {mu}Sv/year for radiation workers and administration staffs, respectively. The doses received by the workers were lower than that of the permissible doses from tritium, i.e. 40 {mu}Sv/year.« less

  12. The influence of different modified graphene on property of DSSCs

    NASA Astrophysics Data System (ADS)

    Xu, Kai; Shen, Yue; Zhang, Zongkun; Cao, Meng; Gu, Feng; Wang, Linjun

    2016-01-01

    Two kinds of modified reduced graphene oxide (rGO) power with different hydrophilic property were synthesized in NH3/hydrazine hydrate (N-rGO) and KOH/hydrazine hydrate (K-rGO) reduction systems, respectively, and be used as counter electrode materials. The as-prepared rGO counter electrodes were confirmed as substitution for Pt counter electrode in dye-sensitized solar cells (DSSCs). The efficiency (η) of DSSCs based on N-rGO counter electrodes achieved 4.72% while that of K-rGO counter electrode was just 3.38%. The electrochemical impedance spectroscopy (EIS) measurements revealed that the hydrophilic K-rGO counter electrode has a low charge transfer resistance (Rct) and the hydrophobic N-rGO counter electrode has a low series resistance (Rs).

  13. Nanopatterned conductive polymer films as a Pt, TCO-free counter electrode for low-cost dye-sensitized solar cells.

    PubMed

    Kwon, Jeong; Ganapathy, Veerappan; Kim, Young Hun; Song, Kyung-Deok; Park, Hong-Gyu; Jun, Yongseok; Yoo, Pil J; Park, Jong Hyeok

    2013-09-07

    A low-cost nanopatterned highly conductive poly(3,4-ethylenedioxythiophene) (PEDOT) thin film was fabricated on a flexible plastic substrate via a chemical polymerization method combined with a nanoimprinting technique and used as a platinum (Pt), TCO-free counter electrode for dye-sensitized solar cells (DSSCs). The catalytic properties of the nanopatterned PEDOT as the counter electrode in DSSCs were studied using cyclic voltammetry, J-V measurements, impedance spectroscopy, and finite-difference time-domain (FDTD) simulations. The nanopatterned PEDOT counter electrodes exhibit better functionality as a counter electrode for tri-iodide reduction when compared to non-patterned PEDOT-based counter electrodes. The Pt and TCO-free DSSCs with a nanopatterned PEDOT-based counter electrode exhibited a power conversion efficiency of 7.1% under one sunlight illumination (100 mW cm(-2)), which is comparable to that of conventional DSSCs with standard platinum Pt/FTO paired counter electrodes. The ability to modulate catalytic functionality with changes in nanoscale morphology represents a promising route for developing new counter electrodes of Pt and TCO-free DSSCs.

  14. Drug Safety - Multiple Languages

    MedlinePlus

    ... Expand Section Guide to Over the Counter Medications - English PDF Guide to Over the Counter Medications - Amarɨñña / ... Information Translations Guide to Over the Counter Medications - English PDF Guide to Over the Counter Medications - العربية ( ...

  15. 2014 Center for Army Leadership Annual Survey of Army Leadership (CASAL): Military Leader Findings

    DTIC Science & Technology

    2015-09-22

    allowed to learn from honest mistakes. Counter- productive Leadership The presence of counter- productive or negative leadership behaviors in the Army...more counter- productive than productive behaviors. This low rate is the same observed in 2013. CASAL results continue to show that counter- productive ...leadership behaviors are strongly associated with lower levels of cohesion, discipline and trust. Leaders who demonstrate counter- productive

  16. Redundant operation of counter modules

    NASA Technical Reports Server (NTRS)

    Nagano, S. (Inventor)

    1980-01-01

    A technique for the redundant operation of counter modules is described. Redundant operation is maintained by detecting the zero state of each counter and clearing the other to that state, thus periodically resynchronizing the counters, and obtaining an output from both counters through AC coupled diode-OR gates. Redundant operation of counter flip flops is maintained in a similar manner, and synchronous operation of redundant squarewave clock generators of the feedback type is effected by connecting together the feedback inputs of the squarewave generators through a coupling resistor, and obtaining an output from both generators through AC coupled diode-OR gates.

  17. Status of the measurement of the nuclear components in cosmic rays with the AMS-02 experiment

    NASA Astrophysics Data System (ADS)

    Donnini, F.

    2017-01-01

    The Alpha Magnetic Spectrometer (AMS-02) is a large-acceptance (0.45 m 2 sr) magnetic spectrometer operating on board the International Space Station since May 2011. One of the main scientific objectives of the mission is the measurement of the nuclei fluxes in cosmic rays (CR). The identification of nuclei is achieved by the combination of independent measurements of the absolute charge, provided by different sub-detectors: the Silicon Tracker, the Time-of-Flight system (TOF), the Ring Imaging Cherenkov Counter (RICH), the Transition Radiation Detector (TRD) and the Electromagnetic Calorimeter (ECAL). In this contribution the results of nuclei fluxes already shown by the AMS collaboration are presented.

  18. A comparison between high-altitude horizon photography and direct sampling of El Chichon cloud particles

    NASA Technical Reports Server (NTRS)

    Coletti, A.; Hofmann, D. J.; Rosen, J. M.

    1986-01-01

    Perturbations to the visible radiation by the El Chichon aerosol layers in the stratosphere observed on May 18, 1982 in Laredo, Texas using in situ, time-lapsed photography are analyzed. The densitometric data are compared with optical counter data. Good correlation is detected for the scattered light intensities of the sky estimated with the two techniques. It is observed that the optical thickness of the stratosphere from 18.8 km to the top of the atmosphere = 0.18 and the residual optical thickness at 27 km = 0.0007. The relationship between the isodensity contours and the height of the observations, cloud cover, specific vertical aerosol distribution, and earth curvature is examined.

  19. Information loss.

    PubMed

    Unruh, William G; Wald, Robert M

    2017-09-01

    The complete gravitational collapse of a body in general relativity will result in the formation of a black hole. Although the black hole is classically stable, quantum particle creation processes will result in the emission of Hawking radiation to infinity and corresponding mass loss of the black hole, eventually resulting in the complete evaporation of the black hole. Semiclassical arguments strongly suggest that, in the process of black hole formation and evaporation, a pure quantum state will evolve to a mixed state, i.e. there will be 'information loss'. There has been considerable controversy over this issue for more than 40 years. In this review, we present the arguments in favor of information loss, and analyze some of the counter-arguments and alternative possibilities.

  20. Information loss

    NASA Astrophysics Data System (ADS)

    Unruh, William G.; Wald, Robert M.

    2017-09-01

    The complete gravitational collapse of a body in general relativity will result in the formation of a black hole. Although the black hole is classically stable, quantum particle creation processes will result in the emission of Hawking radiation to infinity and corresponding mass loss of the black hole, eventually resulting in the complete evaporation of the black hole. Semiclassical arguments strongly suggest that, in the process of black hole formation and evaporation, a pure quantum state will evolve to a mixed state, i.e. there will be ‘information loss’. There has been considerable controversy over this issue for more than 40 years. In this review, we present the arguments in favor of information loss, and analyze some of the counter-arguments and alternative possibilities.

  1. DUPoly process for treatment of depleted uranium and production of beneficial end products

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalb, P.D.; Adams, J.W.; Lageraaen, P.R.

    2000-02-29

    The present invention provides a process of encapsulating depleted uranium by forming a homogeneous mixture of depleted uranium and molten virgin or recycled thermoplastic polymer into desired shapes. Separate streams of depleted uranium and virgin or recycled thermoplastic polymer are simultaneously subjected to heating and mixing conditions. The heating and mixing conditions are provided by a thermokinetic mixer, continuous mixer or an extruder and preferably by a thermokinetic mixer or continuous mixer followed by an extruder. The resulting DUPoly shapes can be molded into radiation shielding material or can be used as counter weights for use in airplanes, helicopters, ships,more » missiles, armor or projectiles.« less

  2. Optimizing microwave photodetection: input-output theory

    NASA Astrophysics Data System (ADS)

    Schöndorf, M.; Govia, L. C. G.; Vavilov, M. G.; McDermott, R.; Wilhelm, F. K.

    2018-04-01

    High fidelity microwave photon counting is an important tool for various areas from background radiation analysis in astronomy to the implementation of circuit quantum electrodynamic architectures for the realization of a scalable quantum information processor. In this work we describe a microwave photon counter coupled to a semi-infinite transmission line. We employ input-output theory to examine a continuously driven transmission line as well as traveling photon wave packets. Using analytic and numerical methods, we calculate the conditions on the system parameters necessary to optimize measurement and achieve high detection efficiency. With this we can derive a general matching condition depending on the different system rates, under which the measurement process is optimal.

  3. FAST NEUTRON SPECTROMETER

    DOEpatents

    Davis, F.J.; Hurst, G.S.; Reinhardt, P.W.

    1959-08-18

    An improved proton recoil spectrometer for determining the energy spectrum of a fast neutron beam is described. Instead of discriminating against and thereby"throwing away" the many recoil protons other than those traveling parallel to the neutron beam axis as do conventional spectrometers, this device utilizes protons scattered over a very wide solid angle. An ovoidal gas-filled recoil chamber is coated on the inside with a scintillator. The ovoidal shape of the sensitive portion of the wall defining the chamber conforms to the envelope of the range of the proton recoils from the radiator disposed within the chamber. A photomultiplier monitors the output of the scintillator, and a counter counts the pulses caused by protons of energy just sufficient to reach the scintillator.

  4. Recent developments in software for the Belle II aerogel RICH

    NASA Astrophysics Data System (ADS)

    Šantelj, L.; Adachi, I.; Dolenec, R.; Hataya, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Križan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Ogawa, S.; Pestotnik, R.; Sumiyoshi, T.; Tabata, M.; Yonenaga, M.; Yusa, Y.

    2017-12-01

    For the Belle II spectrometer a proximity focusing RICH counter with an aerogel radiator (ARICH) will be employed as a PID system in the forward end-cap region of the spectrometer. The detector will provide about 4σ separation of pions and kaons up to momenta of 3.5 GeV/c, at the kinematic limits of the experiment. We present the up-to-date status of the ARICH simulation and reconstruction software, focusing on the recent improvements of the reconstruction algorithms and detector description in the Geant4 simulation. In addition, as a demonstration of detector readout software functionality we show the first cosmic ray Cherenkov rings observed in the ARICH.

  5. Radiocarbon dating of archaeological samples (sambaqui) using CO(2) absorption and liquid scintillation spectrometry of low background radiation.

    PubMed

    Mendonça, Maria Lúcia T G; Godoy, José M; da Cruz, Rosana P; Perez, Rhoneds A R

    2006-01-01

    Sambaqui means, in the Tupi language, a hill of shells. The sambaquis are archaeological sites with remains of pre-historical Brazilian occupation. Since the sambaqui sites in the Rio de Janeiro state region are older than 10,000 years, the applicability of CO(2) absorption on Carbo-sorb and (14)C determination by counting on a low background liquid scintillation counter was tested. In the present work, sambaqui shells were treated with H(3)PO(4) in a closed vessel in order to generate CO(2). The produced CO(2) was absorbed on Carbo-sorb. On saturation about 0.6g of carbon, as CO(2), was mixed with commercial liquid scintillation cocktail (Permafluor), and the (14)C activity determined by counting on a low background counter, Packard Tricarb 3170 TR/SL, for a period of 1000 mins to enable detection of a radiocarbon age of 22,400 BP. But only samples with ages up to 3500 BP were submitted to the method because the samples had been collected in the municipality of Guapimirim, in archaeological sambaqui-type sites belonging to this age range. The same samples were sent to the (14)C Laboratory of the Centro de Energia Nuclear na Agricultura (CENA/USP) where similar results were obtained.

  6. Generation of circularly polarized XUV and soft-x-ray high-order harmonics by homonuclear and heteronuclear diatomic molecules subject to bichromatic counter-rotating circularly polarized intense laser fields

    NASA Astrophysics Data System (ADS)

    Heslar, John; Telnov, Dmitry A.; Chu, Shih-I.

    2017-12-01

    Recently, studies of bright circularly polarized high-harmonic beams from atoms in the soft-x-ray region as a source for x-ray magnetic circular dichroism measurement in a tabletop-scale setup have received considerable attention. In this paper, we address the problem with molecular targets and perform a detailed quantum study of H2 +, CO, and N2 molecules in bichromatic counter-rotating circularly polarized laser fields where we adopt wavelengths (1300 and 790 nm) and intensities (2 ×1014W /cm2 ) reported in a recent experiment [Proc. Natl. Acad. Sci. USA 112, 14206 (2015), 10.1073/pnas.1519666112]. Our treatment of multiphoton processes in homonuclear and heteronuclear diatomic molecules is nonperturbative and based on the time-dependent density-functional theory for multielectron systems. The calculated radiation spectrum contains doublets of left and right circularly polarized harmonics with high-energy photons in the XUV and soft-x-ray ranges. Our results reveal intriguing and substantially different nonlinear optical responses for homonuclear and heteronuclear diatomic molecules subject to circularly polarized intense laser fields. We study in detail the below- and above-threshold harmonic regions and analyze the ellipticity and phase of the generated harmonic peaks.

  7. Dicationic Surfactants with Glycine Counter Ions for Oligonucleotide Transportation.

    PubMed

    Pietralik, Zuzanna; Skrzypczak, Andrzej; Kozak, Maciej

    2016-08-04

    Gemini surfactants are good candidates to bind, protect, and deliver nucleic acids. Herein, the concept of amino acids (namely glycine) as counter ions of gemini surfactants for gene therapy application was explored. This study was conducted on DNA and RNA oligomers and two quaternary bis-imidazolium salts, having 2,5-dioxahexane and 2,8-dioxanonane spacer groups. The toxicity level of surfactants was assessed by an MTT assay, and their ability to bind nucleic acids was tested through electrophoresis. The nucleic acid conformation was established based on circular dichroism and infrared spectroscopic analyses. The structures of the formed complexes were characterized by small-angle scattering of synchrotron radiation. Both studied surfactants appear to be suitable for gene therapy; however, although they vary by only three methylene groups in the spacer, they differ in binding ability and toxicity. The tested oligonucleotides maintained their native conformations upon surfactant addition and the studied lipoplexes formed a variety of structures. In systems based on a 2,5-dioxahexane spacer, a hexagonal phase was observed for DNA-surfactant complexes and a micellar phase was dominant with RNA. For the surfactant with a 2,8-dioxanonane spacer group, the primitive cubic phase prevailed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. An investigation of high-multiplicity gamma events in pp collisions with c.m. energies between 22 and 62 GeV

    NASA Technical Reports Server (NTRS)

    Dell, G. F.; Uto, H.; Yuan, L. C. L.; Amaldi, E.; Beneventano, M.; Borgia, B.; Pistilli, P.; Sestili, I.; Dooher, J.

    1976-01-01

    An experiment was conducted at the CERN intersecting storage rings using colliding proton beams to investigate high-multiplicity gamma-ray events. The objective of the study was to reveal certain features of multiple pion production as well as other possible mechanisms of gamma-ray production. The detector system consisted of ten planes of spark chambers, three scintillation counter hodoscopes and two arrays of lead-glass Cerenkov counters, the first array containing 16 counters and the second, 60 counters. The event trigger was obtained from the Cerenkov counters, and the energies in all the Cerenkov counters after trigger, as well as the information on all the charged particles given by the scintillation counters and spark chambers were recorded on magnetic tape. The relationship between the number of gamma-rays per event and the number of Cerenkov counters triggered by a neutral secondary was established by means of a Monte Carlo calculation.

  9. Low-Cost Flexible Nano-Sulfide/Carbon Composite Counter Electrode for Quantum-Dot-Sensitized Solar Cell

    PubMed Central

    2010-01-01

    Cu2S nanocrystal particles were in situ deposited on graphite paper to prepare nano-sulfide/carbon composite counter electrode for CdS/CdSe quantum-dot-sensitized solar cell (QDSC). By optimization of deposition time, photovoltaic conversion efficiency up to 3.08% was obtained. In the meantime, this composite counter electrode was superior to the commonly used Pt, Au and carbon counter electrodes. Electrochemical impedance spectra further confirmed that low charge transfer resistance at counter electrode/electrolyte interface was responsible for this, implied the potential application of this composite counter electrode in high-efficiency QDSC. PMID:20672135

  10. JASMIN: Japanese-American study of muon interactions and neutron detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakashima, Hiroshi; /JAEA, Ibaraki; Mokhov, N.V.

    Experimental studies of shielding and radiation effects at Fermi National Accelerator Laboratory (FNAL) have been carried out under collaboration between FNAL and Japan, aiming at benchmarking of simulation codes and study of irradiation effects for upgrade and design of new high-energy accelerator facilities. The purposes of this collaboration are (1) acquisition of shielding data in a proton beam energy domain above 100GeV; (2) further evaluation of predictive accuracy of the PHITS and MARS codes; (3) modification of physics models and data in these codes if needed; (4) establishment of irradiation field for radiation effect tests; and (5) development of amore » code module for improved description of radiation effects. A series of experiments has been performed at the Pbar target station and NuMI facility, using irradiation of targets with 120 GeV protons for antiproton and neutrino production, as well as the M-test beam line (M-test) for measuring nuclear data and detector responses. Various nuclear and shielding data have been measured by activation methods with chemical separation techniques as well as by other detectors such as a Bonner ball counter. Analyses with the experimental data are in progress for benchmarking the PHITS and MARS15 codes. In this presentation recent activities and results are reviewed.« less

  11. Adjustable vector Airy light-sheet single optical tweezers: negative radiation forces on a subwavelength spheroid and spin torque reversal

    NASA Astrophysics Data System (ADS)

    Mitri, Farid G.

    2018-01-01

    Generalized solutions of vector Airy light-sheets, adjustable per their derivative order m, are introduced stemming from the Lorenz gauge condition and Maxwell's equations using the angular spectrum decomposition method. The Cartesian components of the incident radiated electric, magnetic and time-averaged Poynting vector fields in free space (excluding evanescent waves) are determined and computed with particular emphasis on the derivative order of the Airy light-sheet and the polarization on the magnetic vector potential forming the beam. Negative transverse time-averaged Poynting vector components can arise, while the longitudinal counterparts are always positive. Moreover, the analysis is extended to compute the optical radiation force and spin torque vector components on a lossless dielectric prolate subwavelength spheroid in the framework of the electric dipole approximation. The results show that negative forces and spin torques sign reversal arise depending on the derivative order of the beam, the polarization of the magnetic vector potential, and the orientation of the subwavelength prolate spheroid in space. The spin torque sign reversal suggests that counter-clockwise or clockwise rotations around the center of mass of the subwavelength spheroid can occur. The results find useful applications in single Airy light-sheet tweezers, particle manipulation, handling, and rotation applications to name a few examples.

  12. A Hypothesis on Biological Protection from Space Radiation Through the Use of New Therapeutic Gases as Medical Counter Measures

    NASA Technical Reports Server (NTRS)

    Schoenfeld, Michael P.; Ansari, Rafat R.; Nakao, Atsunori; Wink, David

    2011-01-01

    Exposure to astronauts could be a significant obstacle for long duration manned space exploration because of current uncertainties regarding the extent of biological effects. Furthermore, concepts for protective shielding also pose a technically challenging issue due to the nature of cosmic radiation and current mass and power constraints with modern exploration technology. As biological damage from exposure is associated with increased oxidative stress, it would be enabling to mitigate and/or prevent stress prior to the development of clinical symptoms and disease. This paper hypothesizes a "systems biology" approach in which a combination of chemical and biological mitigation techniques are used conjunctively. It proposes using new, therapeutic, medical gases as both chemical radioprotectors for radical scavenging and biological promoters for management of the body s response to exposure. From reviewing radiochemistry of water, biological effects of CO, H2, NO, and H2S gas, and mechanisms of radiation biology, it is concluded that this approach may have great therapeutic potential for exposure. Furthermore, it also appears to have potential for curtailing the pathogenesis of other diseases in which oxidative stress has been implicated including cardiovascular disease, cancer, chronic inflammatory disease, hypertension, ischemia/reperfusion injury, acute respiratory distress syndrome, Parkinson s and Alzheimer s disease, cataracts, and aging.

  13. Evolution of surface sensible heat over the Tibetan Plateau under the recent global warming hiatus

    NASA Astrophysics Data System (ADS)

    Zhu, Lihua; Huang, Gang; Fan, Guangzhou; Qu, Xia; Zhao, Guijie; Hua, Wei

    2017-10-01

    Based on regular surface meteorological observations and NCEP/DOE reanalysis data, this study investigates the evolution of surface sensible heat (SH) over the central and eastern Tibetan Plateau (CE-TP) under the recent global warming hiatus. The results reveal that the SH over the CE-TP presents a recovery since the slowdown of the global warming. The restored surface wind speed together with increased difference in ground-air temperature contribute to the recovery in SH. During the global warming hiatus, the persistent weakening wind speed is alleviated due to the variation of the meridional temperature gradient. Meanwhile, the ground surface temperature and the difference in ground-air temperature show a significant increasing trend in that period caused by the increased total cloud amount, especially at night. At nighttime, the increased total cloud cover reduces the surface effective radiation via a strengthening of atmospheric counter radiation and subsequently brings about a clear upward trend in ground surface temperature and the difference in ground-air temperature. Cloud-radiation feedback plays a significant role in the evolution of the surface temperature and even SH during the global warming hiatus. Consequently, besides the surface wind speed, the difference in ground-air temperature becomes another significant factor for the variation in SH since the slowdown of global warming, particularly at night.

  14. Nanodosimetry of (125)I Auger electrons.

    PubMed

    Bantsar, Aliaksandr; Pszona, Stanislaw

    2012-12-01

    The nanodosimetric description of the radiation action of Auger electrons on nitrogen targets of nanometric size is presented. Experimental microdosimetry at nanometer scale for Auger electrons has been accomplished with the set-up called Jet Counter. This consists of a pulse-operated valve which injects an expanding nitrogen jet into an interaction chamber where a gaseous sensitive volume of cylindrical shape is created. The ionization cluster size distributions (ICSD) created by Auger electrons emitted by (125)I while crossing a nanometer-sized volume have been measured. The ICSD for the sensitive volumes corresponding to 3 and 12 nm in diameter (in unit density 1 g/cm(3)) irradiated by electrons emitted by a (125)I source were collected and compared with the corresponding Monte Carlo (MC) simulation. The preliminary results of the experiments with Auger electrons of (125)I interacting with a nitrogen jet having nanometric size comparable to a deoxyribonucleic acid (DNA) and nucleosome, showing the discrete spectrum of ICSD with extended cluster size, are described. The presented paper describes for the first time the nanodosimetric experiments with Auger electrons emitted by (125)I. A set of the new descriptors of the radiation quality describing the radiation effect at nanometer level is proposed. The ICSD were determined for the first time for an Auger emitter of (125)I.

  15. Effect of counter-pulsation control of a pulsatile left ventricular assist device on working load variations of the native heart.

    PubMed

    Choi, Seong Wook; Nam, Kyoung Won; Lim, Ki Moo; Shim, Eun Bo; Won, Yong Soon; Woo, Heung Myong; Kwak, Ho Hyun; Noh, Mi Ryoung; Kim, In Young; Park, Sung Min

    2014-04-03

    When using a pulsatile left ventricular assist device (LVAD), it is important to reduce the cardiac load variations of the native heart because severe cardiac load variations can induce ventricular arrhythmia. In this study, we investigated the effect of counter-pulsation control of the LVAD on the reduction of cardiac load variation. A ventricular electrocardiogram-based counter-pulsation control algorithm for a LVAD was implemented, and the effects of counter-pulsation control of the LVAD on the reduction of the working load variations of the left ventricle were determined in three animal experiments. Deviations of the working load of the left ventricle were reduced by 51.3%, 67.9%, and 71.5% in each case, and the beat-to-beat variation rates in the working load were reduced by 84.8%, 82.7%, and 88.2% in each ease after counter-pulsation control. There were 3 to 12 premature ventricle contractions (PVCs) before counter-pulsation control, but no PVCs were observed during counter-pulsation control. Counter-pulsation control of the pulsatile LVAD can reduce severe cardiac load variations, but the average working load is not markedly affected by application of counter-pulsation control because it is also influenced by temporary cardiac outflow variations. We believe that counter-pulsation control of the LVAD can improve the long-term safety of heart failure patients equipped with LVADs.

  16. Randomness fault detection system

    NASA Technical Reports Server (NTRS)

    Russell, B. Don (Inventor); Aucoin, B. Michael (Inventor); Benner, Carl L. (Inventor)

    1996-01-01

    A method and apparatus are provided for detecting a fault on a power line carrying a line parameter such as a load current. The apparatus monitors and analyzes the load current to obtain an energy value. The energy value is compared to a threshold value stored in a buffer. If the energy value is greater than the threshold value a counter is incremented. If the energy value is greater than a high value threshold or less than a low value threshold then a second counter is incremented. If the difference between two subsequent energy values is greater than a constant then a third counter is incremented. A fault signal is issued if the counter is greater than a counter limit value and either the second counter is greater than a second limit value or the third counter is greater than a third limit value.

  17. Galactic and solar radiation exposure to aircrew during a solar cycle.

    PubMed

    Lewis, B J; Bennett, L G I; Green, A R; McCall, M J; Ellaschuk, B; Butler, A; Pierre, M

    2002-01-01

    An on-going investigation using a tissue-equivalent proportional counter (TEPC) has been carried out to measure the ambient dose equivalent rate of the cosmic radiation exposure of aircrew during a solar cycle. A semi-empirical model has been derived from these data to allow for the interpolation of the dose rate for any global position. The model has been extended to an altitude of up to 32 km with further measurements made on board aircraft and several balloon flights. The effects of changing solar modulation during the solar cycle are characterised by correlating the dose rate data to different solar potential models. Through integration of the dose-rate function over a great circle flight path or between given waypoints, a Predictive Code for Aircrew Radiation Exposure (PCAIRE) has been further developed for estimation of the route dose from galactic cosmic radiation exposure. This estimate is provided in units of ambient dose equivalent as well as effective dose, based on E/H x (10) scaling functions as determined from transport code calculations with LUIN and FLUKA. This experimentally based treatment has also been compared with the CARI-6 and EPCARD codes that are derived solely from theoretical transport calculations. Using TEPC measurements taken aboard the International Space Station, ground based neutron monitoring, GOES satellite data and transport code analysis, an empirical model has been further proposed for estimation of aircrew exposure during solar particle events. This model has been compared to results obtained during recent solar flare events.

  18. Internal Radiation Exposure Dose in Iwaki City, Fukushima Prefecture after the Accident at Fukushima Dai-ichi Nuclear Power Plant

    PubMed Central

    Orita, Makiko; Hayashida, Naomi; Nukui, Hiroshi; Fukuda, Naoko; Kudo, Takashi; Matsuda, Naoki; Fukushima, Yoshiko; Takamura, Noboru

    2014-01-01

    As a result of the accident at the Fukushima Daiichi Nuclear Power Plant (FNPP) on 11 March 2011, a huge amount of radionuclides, including radiocesium, was released and spread over a wide area of eastern Japan. Although three years have passed since the accident, residents around the FNPP are anxious about internal radiation exposure due to radiocesium. In this study, we screened internal radiation exposure doses in Iwaki city of Fukushima prefecture, using a whole-body counter. The first screening was conducted from October 2012 to February 2013, and the second screening was conducted from May to November 2013. Study participants were employees of ALPINE and their families who underwent examination. A total of 2,839 participants (1,366 men and 1,473 women, 1–86 years old) underwent the first screening, and 2,092 (1,022 men and 1,070 women, 1–86 years old) underwent the second screening. The results showed that 99% of subjects registered below 300 Bq per body in the first screening, and all subjects registered below 300 Bq per body in the second screening. The committed effective dose ranged from 0.01–0.06 mSv in the first screening and 0.01–0.02 mSv in the second screening. Long-term follow-up studies are needed to avoid unnecessary chronic internal exposure and to reduce anxiety among the residents by communicating radiation health risks. PMID:25478794

  19. DETERMINATION OF THE BACKGROUND WHILE MEASURING ACTIVITIES OF THE ORDER OF 10$sup -11$ TO 10$sup -13$ CURIE (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Artem'ev, V.V.

    1962-11-01

    Activity measurements must be occasionally carried out in presence of a background radiation with a higher value than the radiation under study. Such cases are encountered in geological prospecting, biological and medical experiments with isotopes having half life periods longer than 10 years, requiring instruments with sensisitivities exceeding the 10/sup -13/ to 10/sup - 14/ curie range. Measurement of activities from 10/sup -11/ to 10/sup -13/ curie with an error of less than 1% requires tens of hours during which the background may vary radically because of the variations of cosmic rays and solar flares. In radiochemical dating studies themore » background usually consists of a constant component due to natural radioactive materials such as KID, and decay products of the U and Th series, and of a variable component primarily controlled by the cosmic radiation. Multiple scattering and absorption events cause a spreading of the spectral lines in neighboring portions of the spectrum of the background radiation; the changes in the second component may be determined by decomposing the count rate. The method was used successfully in mass determinations of C/sup 14/ in geological and archeological samples. The C sample was used to prepare ethyl benzene in which scintillating compounds, such as 2,5 diphenyl oxazol and 1,4-STAdi2,5 phenyl oxazolyl! benzene were dissolved, measuring the activity by means of a scintillation counter and a photomultiplier. (TTT)« less

  20. Internal radiation exposure dose in Iwaki city, Fukushima prefecture after the accident at Fukushima Dai-ichi Nuclear Power Plant.

    PubMed

    Orita, Makiko; Hayashida, Naomi; Nukui, Hiroshi; Fukuda, Naoko; Kudo, Takashi; Matsuda, Naoki; Fukushima, Yoshiko; Takamura, Noboru

    2014-01-01

    As a result of the accident at the Fukushima Daiichi Nuclear Power Plant (FNPP) on 11 March 2011, a huge amount of radionuclides, including radiocesium, was released and spread over a wide area of eastern Japan. Although three years have passed since the accident, residents around the FNPP are anxious about internal radiation exposure due to radiocesium. In this study, we screened internal radiation exposure doses in Iwaki city of Fukushima prefecture, using a whole-body counter. The first screening was conducted from October 2012 to February 2013, and the second screening was conducted from May to November 2013. Study participants were employees of ALPINE and their families who underwent examination. A total of 2,839 participants (1,366 men and 1,473 women, 1-86 years old) underwent the first screening, and 2,092 (1,022 men and 1,070 women, 1-86 years old) underwent the second screening. The results showed that 99% of subjects registered below 300 Bq per body in the first screening, and all subjects registered below 300 Bq per body in the second screening. The committed effective dose ranged from 0.01-0.06 mSv in the first screening and 0.01-0.02 mSv in the second screening. Long-term follow-up studies are needed to avoid unnecessary chronic internal exposure and to reduce anxiety among the residents by communicating radiation health risks.

  1. Neutron relative biological effectiveness in Hiroshima and Nagasaki atomic bomb survivors: a critical review.

    PubMed

    Sasaki, Masao S; Endo, Satoru; Hoshi, Masaharu; Nomura, Taisei

    2016-11-01

    The calculated risk of cancer in humans due to radiation exposure is based primarily on long-term follow-up studies, e.g. the life-span study (LSS) on atomic bomb (A-bomb) survivors in Hiroshima and Nagasaki. Since A-bomb radiation consists of a mixture of γ-rays and neutrons, it is essential that the relative biological effectiveness (RBE) of neutrons is adequately evaluated if a study is to serve as a reference for cancer risk. However, the relatively small neutron component hampered the direct estimation of RBE in LSS data. To circumvent this problem, several strategies have been attempted, including dose-independent constant RBE, dose-dependent variable RBE, and dependence on the degrees of dominance of intermingled γ-rays. By surveying the available literature, we tested the chromosomal RBE of neutrons as the biological endpoint for its equivalence to the microdosimetric quantities obtained using a tissue-equivalent proportional counter (TEPC) in various neutron fields. The radiation weighting factor, or quality factor, Q n , of neutrons as expressed in terms of the energy dependence of the maximum RBE, RBE m , was consistent with that predicted by the TEPC data, indicating that the chromosomally measured RBE was independent of the magnitude of coexisting γ-rays. The obtained neutron RBE, which varied with neutron dose, was confirmed to be the most adequate RBE system in terms of agreement with the cancer incidence in A-bomb survivors, using chromosome aberrations as surrogate markers. With this RBE system, the cancer risk in A-bomb survivors as expressed in unit dose of reference radiation is equally compatible with Hiroshima and Nagasaki cities, and may be potentially applicable in other cases of human radiation exposure. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  2. Comparisons of Integrated Radiation Transport Models with Microdosimetry Data in Spaceflight

    NASA Technical Reports Server (NTRS)

    Cucinotta, Francis A.; Nikjoo, H.; Kim, M. Y.; Hu, X.; Dicello, J. F.; Pisacane, V. L.

    2006-01-01

    Astronauts are exposed to galactic cosmic rays (GCR), trapped protons, and possible solar particle events (SPE) during spaceflight. For such complicated mixtures of radiation types and kinetic energies, tissue equivalent proportional counters (TEPC's) represent a simple time-dependent approach for radiation monitoring. Of interest in radiation protection is the average quality factor of a radiation field defined as a function of linear energy transfer, LET, Q(sub ave)(LET). However TEPC's measure the average quality factors as a function of lineal energy (y), Q(sub ave)(y) defined as the average energy deposition in a volume divided by the average chord length of the volume. Lineal energy, y deviates from LET due to energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector. Using integrated space radiation models that includes the transport code HZETRN/BRYNTRN, the quantum nuclear interaction model, QMSFRG, and results from Monte-Carlo track simulations of TEPC's response to ions, we consider comparisons of model calculations to TEPC results from NASA missions in low Earth orbit and make predictions for lunar and Mars missions. Good agreement between the model and measured spectra from past NASA missions is found. A finding of this work is that TEPC's values for trapped or solar protons of Q(sub ave)(y) range from 1.9-2.5, overestimating Q(sub ave)(LET), which ranges from 1.4-1.6 with both quantities increasing with shielding depth due to nuclear secondaries Comparisons for the complete GCR spectra show that Q(sub ave)(LET) for GCR is approximately 3.5-4.5, while TEPC's measure 2.9-3.4 for Q(sub ave)(y) with the GCR values decreasing with depth as heavy ions are absorbed in shielding material. Our results support the use of TEPC's for space radiation environmental monitoring when computational analysis is used for proper data interpretation.

  3. FLEXIBLE GEIGER COUNTER

    DOEpatents

    Richter, H.G.; Gillespie, A.S. Jr.

    1963-11-12

    A flexible Geiger counter constructed from materials composed of vinyl chloride polymerized with plasticizers or co-polymers is presented. The counter can be made either by attaching short segments of corrugated plastic sleeving together, or by starting with a length of vacuum cleaner hose composed of the above materials. The anode is maintained substantially axial Within the sleeving or hose during tube flexing by means of polystyrene spacer disks or an easily assembled polyethylene flexible cage assembly. The cathode is a wire spiraled on the outside of the counter. The sleeving or hose is fitted with glass end-pieces or any other good insulator to maintain the anode wire taut and to admit a counting gas mixture into the counter. Having the cathode wire on the outside of the counter substantially eliminates the objectional sheath effect of prior counters and permits counting rates up to 300,000 counts per minute. (AEC)

  4. Signaling communication events in a computer network

    DOEpatents

    Bender, Carl A.; DiNicola, Paul D.; Gildea, Kevin J.; Govindaraju, Rama K.; Kim, Chulho; Mirza, Jamshed H.; Shah, Gautam H.; Nieplocha, Jaroslaw

    2000-01-01

    A method, apparatus and program product for detecting a communication event in a distributed parallel data processing system in which a message is sent from an origin to a target. A low-level application programming interface (LAPI) is provided which has an operation for associating a counter with a communication event to be detected. The LAPI increments the counter upon the occurrence of the communication event. The number in the counter is monitored, and when the number increases, the event is detected. A completion counter in the origin is associated with the completion of a message being sent from the origin to the target. When the message is completed, LAPI increments the completion counter such that monitoring the completion counter detects the completion of the message. The completion counter may be used to insure that a first message has been sent from the origin to the target and completed before a second message is sent.

  5. 21 CFR 862.2320 - Beta or gamma counter for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Beta or gamma counter for clinical use. 862.2320... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2320 Beta or gamma counter for clinical use. (a) Identification. A beta or gamma counter for...

  6. 78 FR 19718 - Modifications To Labeling of Nicotine Replacement Therapy Products for Over-the-Counter Human Use

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-02

    ...] Modifications To Labeling of Nicotine Replacement Therapy Products for Over-the-Counter Human Use AGENCY: Food...-counter nicotine replacement therapy products, related to concomitant use with other nicotine-containing... over-the- counter nicotine replacement therapy products for their approved intended use as aids to...

  7. 21 CFR 864.5200 - Automated cell counter.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated cell counter. 864.5200 Section 864.5200....5200 Automated cell counter. (a) Identification. An automated cell counter is a fully-automated or semi-automated device used to count red blood cells, white blood cells, or blood platelets using a sample of the...

  8. 21 CFR 892.1130 - Nuclear whole body counter.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nuclear whole body counter. 892.1130 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1130 Nuclear whole body counter. (a) Identification. A nuclear whole body counter is a device intended to measure the amount of radionuclides in the...

  9. 21 CFR 892.1130 - Nuclear whole body counter.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nuclear whole body counter. 892.1130 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1130 Nuclear whole body counter. (a) Identification. A nuclear whole body counter is a device intended to measure the amount of radionuclides in the...

  10. Instability of counter-rotating stellar disks

    NASA Astrophysics Data System (ADS)

    Hohlfeld, R. G.; Lovelace, R. V. E.

    2015-09-01

    We use an N-body simulation, constructed using GADGET-2, to investigate an accretion flow onto an astrophysical disk that is in the opposite sense to the disk's rotation. In order to separate dynamics intrinsic to the counter-rotating flow from the impact of the flow onto the disk, we consider an initial condition in which the counter-rotating flow is in an annular region immediately exterior the main portion of the astrophysical disk. Such counter-rotating flows are seen in systems such as NGC 4826 (known as the "Evil Eye Galaxy"). Interaction between the rotating and counter-rotating components is due to two-stream instability in the boundary region. A multi-armed spiral density wave is excited in the astrophysical disk and a density distribution with high azimuthal mode number is excited in the counter-rotating flow. Density fluctuations in the counter-rotating flow aggregate into larger clumps and some of the material in the counter-rotating flow is scattered to large radii. Accretion flow processes such as this are increasingly seen to be of importance in the evolution of multi-component galactic disks.

  11. The response of a scintillation counter below an emulsion chamber to heavy nucleus interactions in the chamber

    NASA Technical Reports Server (NTRS)

    Burnett, T. H.; Dake, S.; Derrickson, J. H.; Fountain, W. F.; Fuki, M.; Gregory, J. C.; Hayashi, T.; Hayashi, T.; Holynski, R.; Iwai, J.; hide

    1985-01-01

    In 1982 a hybrid electronic counter-emulsion chamber experiment was flown on a balloon to study heavy nucleus interactions in the 20 to approximately 100 GeV/AMU energy range. A gas Cerenkov counter, two solid Cerenkov counters, and a proportional counter hodoscope gave the primary energy, the primary charge and the trajectory of the particles, respectively. Using the trajectory information cosmic ray nuclei of Z 10 were found reliably and efficiently, and interaction characteristics of the Fe group nuclei were measured in the chamber. A plastic scintillator below the emulsion chamber responded to showers resulting from interactions in the chamber and to noninteracting nuclei. Data on the response of the counter have been compared with simulations of hadronic-electromagnetic cascades to derive the average neutral energy fraction released by the heavy interactions, and to predict the performance of this kind of counter at higher energies. For the interacting events of highest produced particles multiplicity comparison between various simulations and the shower counter signal have been made.

  12. Facile synthesis of nitrogen-doped reduced graphene oxide as an efficient counter electrode for dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Wei, Liguo; Wang, Ping; Yang, Yulin; Luo, Ruidong; Li, Jinqi; Gu, Xiaohu; Zhan, Zhaoshun; Dong, Yongli; Song, Weina; Fan, Ruiqing

    2018-04-01

    A nitrogen-doped reduced graphene oxide (N-RGO) nanosheet was synthesized by a simple hydrothermal method and characterized by X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and scanning electrode microscopy. After being deposited as counter electrode film for dye-sensitized solar cells (DSSCs), it is found that the synthesized N-RGO nanosheet has smaller charge-transfer resistance and better electrocatalytic activity towards reduction of triiodide than the reduced graphene oxide (RGO) nanosheet. Consequently, the DSSCs based on the N-RGO counter electrode achieve an energy conversion efficiency of 4.26%, which is higher than that of the RGO counter electrode (2.85%) prepared under the same conditions, and comparable to the value (5.21%) obtained with the Pt counter electrode as a reference. This N-RGO counter electrode offers the advantages of not only saving the cost of Pt itself but also simplifying the process of counter electrode preparation. Therefore, an inexpensive N-RGO nanosheet is a promising counter electrode material to replace noble metal Pt. [Figure not available: see fulltext.

  13. Less haste, less waste: on recycling and its limits in strand displacement systems

    PubMed Central

    Condon, Anne; Hu, Alan J.; Maňuch, Ján; Thachuk, Chris

    2012-01-01

    We study the potential for molecule recycling in chemical reaction systems and their DNA strand displacement realizations. Recycling happens when a product of one reaction is a reactant in a later reaction. Recycling has the benefits of reducing consumption, or waste, of molecules and of avoiding fuel depletion. We present a binary counter that recycles molecules efficiently while incurring just a moderate slowdown compared with alternative counters that do not recycle strands. This counter is an n-bit binary reflecting Gray code counter that advances through 2n states. In the strand displacement realization of this counter, the waste—total number of nucleotides of the DNA strands consumed—is polynomial in n, the number of bits of the counter, while the waste of alternative counters grows exponentially in n. We also show that our n-bit counter fails to work correctly when many (Θ(n)) copies of the species that represent the bits of the counter are present initially. The proof applies more generally to show that in chemical reaction systems where all but one reactant of each reaction are catalysts, computations longer than a polynomial function of the size of the system are not possible when there are polynomially many copies of the system present. PMID:22649584

  14. High-efficiency and low-background multi-segmented proportional gas counter for β-decay spectroscopy

    NASA Astrophysics Data System (ADS)

    Mukai, M.; Hirayama, Y.; Watanabe, Y. X.; Schury, P.; Jung, H. S.; Ahmed, M.; Haba, H.; Ishiyama, H.; Jeong, S. C.; Kakiguchi, Y.; Kimura, S.; Moon, J. Y.; Oyaizu, M.; Ozawa, A.; Park, J. H.; Ueno, H.; Wada, M.; Miyatake, H.

    2018-03-01

    A multi-segmented proportional gas counter (MSPGC) with high detection efficiency and low-background event rate has been developed for β-decay spectroscopy. The MSPGC consists of two cylindrically aligned layers of 16 counters (32 counters in total). Each counter has a long active length and small trapezoidal cross-section, and the total solid angle of the 32 counters is 80% of 4 π. β-rays are distinguished from the background events including cosmic-rays by analyzing the hit patterns of independent counters. The deduced intrinsic detection efficiency of each counter was almost 100%. The measured background event rate was 0.11 counts per second using the combination of veto counters for cosmic-rays and lead block shields for background γ-rays. The MSPGC was applied to measure the β-decay half-lives of 198Ir and 199mPt. The evaluated half-lives of T1/2 = 9 . 8(7) s and 12.4(7) s for 198Ir and 199mPt, respectively, were in agreement with previously reported values. The estimated absolute detection efficiency of the MSPGC from GEANT4 simulations was consistent with the evaluated efficiency from the analysis of the β- γ spectroscopy of 199Pt, saturating at approximately 60% for Qβ > 4 MeV.

  15. Development of a high-sensitivity BGO well counter for small animal PET studies.

    PubMed

    Yamamoto, Seiichi; Watabe, Hiroshi; Kanai, Yasukazu; Watabe, Tadashi; Imaizumi, Masao; Shimosegawa, Eku; Hatazawa, Jun

    2012-01-01

    In quantitative measurements of small animal PET studies, blood sampling is limited due to the small amounts of blood such animals can provide. In addition, injection doses are quite limited. In this situation, a high-sensitivity well counter would be useful for reducing the amount of the blood sample needed from small animals. Bismuth germinate (BGO) has a high stopping power for high-energy gamma rays compared to NaI(Tl), which is commonly used for conventional well counters. We have developed a BGO well counter and have tested it for blood-sampling measurements in small animals. The BGO well counter uses a square BGO block (59 × 59 × 50 mm) with a square open space (27 × 27 × 34 mm) in the center of the block. The BGO block was optically coupled to a 59-mm square-shaped photomultiplier tube (PMT). Signals from the PMT were digitally processed for the integration and energy window setting. The results showed that the energy spectrum of the BGO well counter measured with a Na-22 point source provided counts that were about 6 times higher for a 1022-keV (511 keV × 2) gamma peak than the spectrum of a 2-in. NaI(Tl) well counter. The relative sensitivity of the developed BGO well counter was 3.4 times higher than that of a NaI(Tl) well counter. The time activity curve of arterial blood was obtained successfully with the BGO well counter for a F-18-FDG study on rat. The BGO well counter will contribute to reducing the amount of sampled blood and to improving the throughput of quantitative measurements in small animal PET studies.

  16. Over-the-counter Acne Treatments

    PubMed Central

    Graber, Emmy M.

    2012-01-01

    Acne is a common dermatological disorder that most frequently affects adolescents; however, individuals may be affected at all ages. Many people who suffer from acne seek treatment from both prescription and over-the-counter acne medications. Due to convenience, lower cost, and difficulty getting an appointment with a dermatologist, the use of over-the-counter acne treatments is on the rise. As the plethora of over-the-counter acne treatment options can be overwhelming, it is important that dermatologists are well-versed on this subject to provide appropriate information about treatment regimens and potential drug interactions and that their patients see them as well-informed. This article reviews the efficacy of various over-the-counter acne treatments based on the current literature. A thorough literature review revealed there are many types of over-the-counter acne treatments and each are designed to target at least one of the pathogenic pathways that are reported to be involved in the development of acne lesions. Many of the key over-the-counter ingredients are incorporated in different formulations to broaden the spectrum and consumer appeal of available products. Unfortunately, many over-the-counter products are not well-supported by clinical studies, with a conspicuous absence of double-blind or investigator-blind, randomized, vehicle-controlled studies. Most studies that do exist on over-the-counter acne products are often funded by the manufacturer. Use of over-the-counter acne treatments is a mainstay in our society and it is important that dermatologists are knowledgeable about the different options, including potential benefits and limitations. Overall, over-the-counter acne therapies can be classified into the following five major groups: cleansers, leave-on products, mechanical treatments, essential oils, and vitamins. PMID:22808307

  17. Over-the-counter medications containing diphenhydramine and doxylamine used by older adults to improve sleep.

    PubMed

    Abraham, Olufunmilola; Schleiden, Loren; Albert, Steven M

    2017-08-01

    Background The unintentional misuse of over-the-counter sleep aids among older adults is an important public health problem and a focus of Healthy People 2020. Accordingly, the 2015 Beers Criteria for Potentially Inappropriate Medication Use in Older Adults recommends that individuals 65 years or older avoid use of diphenhydramine and doxylamine; however, many over-the-counter sleep products contain these active ingredients. Objective To identify the proportion of older adults using an over-the-counter medication containing diphenhydramine or doxylamine, and compare their characteristics with older adults using an over-the-counter medication that does not contain these ingredients. Setting Study participants were recruited from the Community Registry of the Pittsburgh Claude D. Pepper Older Americans Independence Center. Method The study sample was taken from a larger survey of 1025 participants on sleep health and over-the-counter sleep medication use conducted from February to April 2015. A subset of 169 participants aged 65 and older reporting taking at least one over-the-counter product to improve sleep within the past 30 days (16.5%) were selected for our analysis on associations between participant characteristics and potentially inappropriate use of over-the-counter sleep medications. Main outcome measure The proportion and characteristics of older adults taking at least one over-the-counter medication containing diphenhydramine or doxylamine. Results Of the 223 over-the-counter sleep medications listed by participants, 115 (52%) contained diphenhydramine or doxylamine. Using the Beers Criteria, we found that more than half of participants (59%) had used a potentially inappropriate over-the-counter medication containing diphenhydramine or doxylamine to improve sleep within the past 30 days. Participants taking at least one diphenhydramine or doxylamine containing medication were less likely to be aware of any safety risks in taking over-the-counter sleep medications than participants not taking these products (38 vs 49%, p = 0.016). Conclusion A majority of older adults in a limited sample from the United States taking an over-the-counter medication to improve sleep are taking a product containing diphenhydramine or doxylamine, both of which are classified as potentially inappropriate for older adults. Awareness of the safety risks of over-the-counter medications and addressing conditions that impact sleep quality could be facilitated through consultation with pharmacists and other healthcare providers.

  18. Reliability of Metrics Associated with a Counter-Movement Jump Performed on a Force Plate

    ERIC Educational Resources Information Center

    Lombard, Wayne; Reid, Sorrel; Pearson, Keagan; Lambert, Michael

    2017-01-01

    The counter-movement jump is a consequence of maximal force, rate of force developed, and neuromuscular coordination. Thus, the counter-movement jump has been used to monitor various training adaptations. However, the smallest detectable difference of counter-movement jump metrics has yet to be established. The objective of the present study was…

  19. Counter-transference and counter-experience in the treatment of violence prone youth.

    PubMed

    King, C H

    1976-01-01

    The constant confrontation inherent in therapeutic intervention with violence prone children, some of whome have committed homicide, is explored. Problems unique to work with these youths are discussed in terms of counter-transference issues for clinicians and counter-experience of teachers and child care workers. Suggestions for training and supervision are offered.

  20. Operations-Focused Optimized Theater Weather Sensing Strategies Using Preemptive Binary Integer Programming

    DTIC Science & Technology

    2009-03-01

    8217 Clear old problem data Do While Trim(Sheets("Campaign").Range("AF" & CStr (LOOP_COUNTER))) <> "" LOOP_COUNTER = LOOP_COUNTER + 1 Loop Do While...Trim(Sheets("Campaign").Range("A" & CStr (LOOP_COUNTER))) <> "" ’ Loop through all problem instances Sheets("Campaign").Range("R1:AF1").Rows...total number of locations M = Sheets("Campaign").Range("F" & CStr (LOOP_COUNTER)) ’ Record total number of sensor types N

  1. Dynamic pulse difference circuit

    DOEpatents

    Erickson, Gerald L.

    1978-01-01

    A digital electronic circuit of especial use for subtracting background activity pulses in gamma spectrometry comprises an up-down counter connected to count up with signal-channel pulses and to count down with background-channel pulses. A detector responsive to the count position of the up-down counter provides a signal when the up-down counter has completed one scaling sequence cycle of counts in the up direction. In an alternate embodiment, a detector responsive to the count position of the up-down counter provides a signal upon overflow of the counter.

  2. Real-time garbage collection for list processing

    NASA Technical Reports Server (NTRS)

    Shuler, R. L., Jr. (Inventor)

    1986-01-01

    In a list processing system, small reference counters are maintained in conjunction with memory cells for the purpose of identifying memory cells that become available for re-use. The counters are updated as references to the cells are created and destroyed, and when a counter of a cell is decremented to logical zero the cell is immediately returned to a list of free cells. In those cases where a counter must be incremented beyond the maximum value that can be represented in a small counter, the cell is restructured so that the additional reference count can be represented. The restructuring involves allocating an additional cell, distributing counter, tag, and pointer information among the two cells, and linking both cells appropriately into the existing list structure.

  3. A new optical ice particle counter at LACIS

    NASA Astrophysics Data System (ADS)

    Bieligk, Henner; Voelker, Georg Sebastian; Clauss, Tina; Grundmann, Marius; Stratmann, Frank

    2014-05-01

    Clouds play an important role within the climate system, especially for the radiative energy budget of the earth. The radiative properties of a cloud depend strongly on the fractions of ice crystals and water droplets, their size distributions, and the ice crystal shapes within the particular cloud. One option to gain this kind of information is using optical particle counters. A new optical particle counter is developed for laboratory work and is based on the concept of the Thermostabilized Optical Particle Spectrometer for the Detection of Ice Particles (TOPS-Ice, Clauss et al., 2013). TOPS-Ice uses linearly polarized green laser light and the depolarization of the scattered light at a scattering angle of 42.5° to discriminate between liquid water droplets and ice crystals in the lower μm range. However, the measurements are usually limited to ice fractions in the order of 1%. To improve the determination of the ice fraction, several modifications of the original setup are implemented including an additional detection system at another scattering angle. The new scattering angle is optimized for least interference between the droplet and ice signals. This is achieved by finding the angle with the maximum difference in scattered intensity of water droplets compared to ice crystals with the same volume equivalent diameter. The suitable scattering angle of 100° for linearly polarized light was chosen based on calculations using T-Matrix method, Lorenz-Mie theory, Müller matrices and distribution theory. The new optical setup is designed to run in combination with a laminar flow tube, the so-called Leipzig Aerosol Cloud Interaction Simulator (LACIS, Stratmann et al., 2004; Hartmann et al., 2011). Using LACIS and its precisely controlled thermodynamic conditions, we are able to form small water droplets and ice crystals which will then be detected, classified and sized by our new optical device. This setup is planned to be tested in ice measurements including Snomax® and several dusts (e.g. illite, kaolinite, ATD) as ice nuclei which all show different behaviors in ice formation. Furthermore, a detailed comparison of both instruments TOPS-Ice and the new setup is planned. This project is part of the Leipzig Graduate School on Clouds, Aerosols and Radiation and is partly supported by the German Research Foundation (DFG project WE 4722/1-1) within the DFG Research Unit FOR 1525 INUIT. Clauss, T., Kiselev, A., Hartmann, S., Augustin, S., Pfeifer, S., Niedermeier, D., Wex, H., and Stratmann, F, 2013, Application of linear polarized light for the discrimination of frozen and liquid droplets in ice nucleation experiments, Atmos. Meas. Tech., 6, 1041-1052. Hartmann, S., Niedermeier, D., Voigtländer, J., Clauss, T., Shaw, R. A., Kiselev, A., and Stratmann, F., 2011, Homogeneous and heterogeneous ice nucleation at LACIS: operating principle and theoretical studies, Atmos. Chem. Phys., 11, 1753-1767. Stratmann, F., Kiselev, A., Wurzler, S., Wendisch, M., Heintzenberg, J., Charlson, R. J., Diehl, K., Wex, H., and Schmidt, S., 2004, Laboratory Studies and Numerical Simulations of Cloud Droplet Formation under Realistic Supersaturation Conditions, J. Atmos. Oceanic. Technol., 21, 876-887.

  4. Low-power low-noise mixed-mode VLSI ASIC for infinite dynamic range imaging applications

    NASA Astrophysics Data System (ADS)

    Turchetta, Renato; Hu, Y.; Zinzius, Y.; Colledani, C.; Loge, A.

    1998-11-01

    Solid state solutions for imaging are mainly represented by CCDs and, more recently, by CMOS imagers. Both devices are based on the integration of the total charge generated by the impinging radiation, with no processing of the single photon information. The dynamic range of these devices is intrinsically limited by the finite value of noise. Here we present the design of an architecture which allows efficient, in-pixel, noise reduction to a practically zero level, thus allowing infinite dynamic range imaging. A detailed calculation of the dynamic range is worked out, showing that noise is efficiently suppressed. This architecture is based on the concept of single-photon counting. In each pixel, we integrate both the front-end, low-noise, low-power analog part and the digital part. The former consists of a charge preamplifier, an active filter for optimal noise bandwidth reduction, a buffer and a threshold comparator, and the latter is simply a counter, which can be programmed to act as a normal shift register for the readout of the counters' contents. Two different ASIC's based on this concept have been designed for different applications. The first one has been optimized for silicon edge-on microstrips detectors, used in a digital mammography R and D project. It is a 32-channel circuit, with a 16-bit binary static counter.It has been optimized for a relatively large detector capacitance of 5 pF. Noise has been measured to be equal to 100 + 7*Cd (pF) electron rms with the digital part, showing no degradation of the noise performances with respect to the design values. The power consumption is 3.8mW/channel for a peaking time of about 1 microsecond(s) . The second circuit is a prototype for pixel imaging. The total active area is about (250 micrometers )**2. The main differences of the electronic architecture with respect to the first prototype are: i) different optimization of the analog front-end part for low-capacitance detectors, ii) in- pixel 4-bit comparator-offset compensation, iii) 15-bit pseudo-random counter. The power consumption is 255 (mu) W/channel for a peaking time of 300 ns and an equivalent noise charge of 185 + 97*Cd electrons rms. Simulation and experimental result as well as imaging results will be presented.

  5. Compact fission counter for DANCE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, C Y; Chyzh, A; Kwan, E

    2010-11-06

    The Detector for Advanced Neutron Capture Experiments (DANCE) consists of 160 BF{sub 2} crystals with equal solid-angle coverage. DANCE is a 4{pi} {gamma}-ray calorimeter and designed to study the neutron-capture reactions on small quantities of radioactive and rare stable nuclei. These reactions are important for the radiochemistry applications and modeling the element production in stars. The recognition of capture event is made by the summed {gamma}-ray energy which is equivalent of the reaction Q-value and unique for a given capture reaction. For a selective group of actinides, where the neutron-induced fission reaction competes favorably with the neutron capture reaction, additionalmore » signature is needed to distinguish between fission and capture {gamma} rays for the DANCE measurement. This can be accomplished by introducing a detector system to tag fission fragments and thus establish a unique signature for the fission event. Once this system is implemented, one has the opportunity to study not only the capture but also fission reactions. A parallel-plate avalanche counter (PPAC) has many advantages for the detection of heavy charged particles such as fission fragments. These include fast timing, resistance to radiation damage, and tolerance of high counting rate. A PPAC also can be tuned to be insensitive to {alpha} particles, which is important for experiments with {alpha}-emitting actinides. Therefore, a PPAC is an ideal detector for experiments requiring a fast and clean trigger for fission. A PPAC with an ingenious design was fabricated in 2006 by integrating amplifiers into the target assembly. However, this counter was proved to be unsuitable for this application because of issues related to the stability of amplifiers and the ability to separate fission fragments from {alpha}'s. Therefore, a new design is needed. A LLNL proposal to develop a new PPAC for DANCE was funded by NA22 in FY09. The design goal is to minimize the mass for the proposed counter and still be able to maintain a stable operation under extreme radioactivity and the ability to separate fission fragments from {alpha}'s. In the following sections, the description is given for the design and performance of this new compact PPAC, for studying the neutron-induced reactions on actinides using DANCE at LANL.« less

  6. An easy-to-operate portable pulse-height analysis system for area monitoring with TEPC in radiation protection

    NASA Astrophysics Data System (ADS)

    Kunz, A.; Pihet, P.; Arend, E.; Menzel, H. G.

    1990-12-01

    A portable area monitor for the measurement of dose-equivalent quantities in practical radiation-protection work has been developed. The detector applied is a low-pressure proportional counter (TEPC) used in microdosimetry. The complex analysis system required has been optimized with regard to low power consumption and small size to achieve a real operational survey meter. The newly designed electronic includes complete analog, digital and microprocessor boards. It presents the characteristic of fast pulse-height processing over a large (5 decades) dynamic range. Three original circuits have been specifically developed, consisting of: (1) a miniaturized adjustable high-voltage power supply with low ripple and high stability; (2) a double spectroscopy amplifier with constant gain ratio and common pole-zero stage; and (3) an analog-to-digital converter with quasi-logarithmic characteristics based on a flash converter using fast comparators associated in parallel. With the incorporated single-board computer, the maximal total power consumption is 5 W, enabling 40 hours operation time with batteries. With minor adaptations the equipment is proposed as a low-cost solution for various measuring problems in environmental studies.

  7. Intensity of primary cosmic-ray electrons of energy exceeding 8 GeV

    NASA Technical Reports Server (NTRS)

    Freier, P.; Gilman, C.; Waddington, C. J.

    1977-01-01

    Results are reported for measurement of the intensity and energy spectrum of primary cosmic-ray electrons with a spark-chamber-counter-emulsion detector flown at a mean altitude of 3 g/sq cm residual atmosphere. A least-squares fit to the flight data yields an electron spectrum from 8 to 80 GeV of approximately 93E to the -2.91 power electrons/sq m/sec per sr/GeV. The results are compared with those of previous experiments as well as with the spectrum obtained for galactic nonthermal radiation. It is concluded that a 'clumpy' magnetic field proportional to the square root of matter density is consistent with measurements of high-energy electrons and synchrotron radiation toward the center of the Galaxy, that a gradual steepening of the electron spectrum relative to the proton spectrum is consistent with an electron lifetime of 1 million years, and that the density of cosmic-ray nucleons and electrons should be essentially uniform throughout the Galaxy if the nucleons have the same lifetime as the electrons and if they traversed 4 to 5 g/sq cm in that lifetime.

  8. Track Structure Model for Radial Distributions of Electron Spectra and Event Spectra from High-Energy Ions

    NASA Technical Reports Server (NTRS)

    Cucinotta, F. A.; Katz, R.; Wilson, J. W.

    1998-01-01

    An analytic method is described for evaluating the average radial electron spectrum and the radial and total frequency-event spectrum for high-energy ions. For high-energy ions, indirect events make important contributions to frequency-event spectra. The method used for evaluating indirect events is to fold the radial electron spectrum with measured frequency-event spectrum for photons or electrons. The contribution from direct events is treated using a spatially restricted linear energy transfer (LET). We find that high-energy heavy ions have a significantly reduced frequency-averaged final energy (yF) compared to LET, while relativistic protons have a significantly increased yF and dose-averaged lineal energy (yD) for typical site sizes used in tissue equivalent proportional counters. Such differences represent important factors in evaluating event spectra with laboratory beams, in space- flight, or in atmospheric radiation studies and in validation of radiation transport codes. The inadequacy of LET as descriptor because of deviations in values of physical quantities, such as track width, secondary electron spectrum, and yD for ions of identical LET is also discussed.

  9. Neutron relative biological effectiveness in Hiroshima and Nagasaki atomic bomb survivors: a critical review

    PubMed Central

    Sasaki, Masao S.; Endo, Satoru; Hoshi, Masaharu; Nomura, Taisei

    2016-01-01

    The calculated risk of cancer in humans due to radiation exposure is based primarily on long-term follow-up studies, e.g. the life-span study (LSS) on atomic bomb (A-bomb) survivors in Hiroshima and Nagasaki. Since A-bomb radiation consists of a mixture of γ-rays and neutrons, it is essential that the relative biological effectiveness (RBE) of neutrons is adequately evaluated if a study is to serve as a reference for cancer risk. However, the relatively small neutron component hampered the direct estimation of RBE in LSS data. To circumvent this problem, several strategies have been attempted, including dose-independent constant RBE, dose-dependent variable RBE, and dependence on the degrees of dominance of intermingled γ-rays. By surveying the available literature, we tested the chromosomal RBE of neutrons as the biological endpoint for its equivalence to the microdosimetric quantities obtained using a tissue-equivalent proportional counter (TEPC) in various neutron fields. The radiation weighting factor, or quality factor, Qn, of neutrons as expressed in terms of the energy dependence of the maximum RBE, RBEm, was consistent with that predicted by the TEPC data, indicating that the chromosomally measured RBE was independent of the magnitude of coexisting γ-rays. The obtained neutron RBE, which varied with neutron dose, was confirmed to be the most adequate RBE system in terms of agreement with the cancer incidence in A-bomb survivors, using chromosome aberrations as surrogate markers. With this RBE system, the cancer risk in A-bomb survivors as expressed in unit dose of reference radiation is equally compatible with Hiroshima and Nagasaki cities, and may be potentially applicable in other cases of human radiation exposure. PMID:27614201

  10. AN EXTERNAL RADIATION BELT AT A HEIGHT OF 320 KM ABOVE THE EARTH (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vernov, S.N.; Savenko, I.A.; Shavrin, P.I.

    1961-10-01

    The orbit of the second Russian sputnik was almost circular with altitude extremes of 307 and 339 km. The count rate obtained from a scintillation counter (NaI (Tl) crystall on board the sputnik showed an increase from 4 to 11 disinteg/cm/sup 2/-sec on going from the equator to latitudes of plus or minus 40 to 50 deg due to the variation in cosmic ray count with latitude. Then, a sharp increase in count rate of 20-600 disinteg/cm/sup 2/-sec was observed at geometrical latitudes 50 to 65 deg . Conjugate points were determined, where a zone of increased activity in Siberiamore » was related with a region in the South Indian Ocean, and a zone in North America was related with a zone in the South Pacific Ocean. Thus, zones of increased radiation in the Northern Hemisphere were related to corresponding zones in the Southern Hemisphere by means of the force lines of the geomagnetic field which determines the external radiation belt. The limit of the radiation belt at small latitudes corresponds with the isocline delta = 70 deg in the Northern Hemisphere and with delta = 66 deg in the Southern Hemisphere. The radiation was found to be due to gamma rays having an energy of 100 to 300 kev which originated from the slow-down of electrons hitting the shell of the sputnik. It was estimated that the upper limit of the lifetime of the electrons in the belt was 10/sup 6/to 10/ sup 8/ seconds. Hence it is more likely that the electrons are captured by local acceleration of electrons within the limits of the geomagnetic field than in accordance with a neutron hypothesis (TTT)« less

  11. OCCURRENCE OF A SHORT-LIVED INCREASE IN RADIATION INTENSITY DETECTED ON AUGUST 20, 1960 IN THE SECOND SPUTNIK (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurnosova, L.V.; Razorenov, L.A.; Fradkin, M.I.

    1963-01-01

    Data obtained during the flight of the second Sputnik on an increase in the intensity of radiation due to charged particles are presented. This increase was noted on August 20, 1980, at 7 hours and 40 minutes world time. The detection instrument consisted of a telescope of two rows of gas-discharge counters with a geometry factor of 2.5 x 10/sup -4/ m sterad and a resolution time of 2 x 10/sup -5/ seconds. The increase was noted when the ship was in the northern hemisphere in the latitudes 50 to 60 deg . It was not registered at other timesmore » when the ship passed through approximately the same geographical region. It was therefore concluded that the rise in radiation was due to a flare of particles from the sun and not to traversal through a radiation belt. This conclusion was also supported by an increase in detection of particles with atomic numbers greater than five. The counting rate of particles with Z greater than 5 was found at this time to be 4.0 plus or minus 1.4 particles/minute as compared to an average count of 0.7 plus or minus 0.1 particles/minute. It is pointed out that the sun was active at the time of the flight of the second Sputnik and in fact a flare of intensity 2/sup +/ had died down just before the increase in radiation was noted. A chance coincidence of these two events has a probability of not more than 0.06. (TTT)« less

  12. Authenticated, private, and secured smart cards (APS-SC)

    NASA Astrophysics Data System (ADS)

    Szu, Harold; Mehmood, Amir

    2006-04-01

    From historical perspective, the recent advancements in better antenna designs, low power circuitry integrations and inexpensive fabrication materials have made possible a miniature counter-measure against Radar, a clutter behaving like a fake target return called Digital Reflection Frequency Modulation (DRFM). Such a military counter-measure have found its way in the commerce as a near field communication known as Radio Frequency Identification (RFID), a passive or active item tag T attached to every readable-writable Smart Card (SC): Passports ID, medical patient ID, biometric ID, driver licenses, book ID, library ID, etc. These avalanche phenomena may be due to the 3 rd Gen phones seeking much more versatile & inexpensive interfaces, than the line-of-sight bar-code optical scan. Despite of the popularity of RFID, the lacking of Authenticity, Privacy and Security (APS) protection restricted somewhat the wide spread commercial, financial, medical, legal, and militarily applications. Conventional APS approach can obfuscate a private passkey K of SC with the tag number T or the reader number R, or both, i.e. only T*K or R*K or both will appear on them, where * denotes an invertible operation, e.g. EXOR, but not limited to it. Then, only the authentic owner, knowing all, can inverse the operation, e.g. EXOR*EXOR= I to find K. However, such an encryption could be easily compromised by a hacker seeking exhaustively by comparison based on those frequently used words. Nevertheless, knowing biological wetware lesson for power of pairs sensors and Radar hardware counter-measure history, we can counter the counter-measure DRFM, instead using one RFID tag per SD, we follow the Nature adopting two ears/tags, e.g. each one holding portions of the ID or simply two different ID's readable only by different modes of the interrogating reader, followed by brain central processor in terms of nonlinear invertible shufflers mixing two ID bits. We prefer to adopt such a hardware-software combined hybrid approach because of a too limited phase space of a single RFID for any meaningful encryption approach. Furthermore, a useful biological lesson is not to put all eggs in one basket, "if you don't get it all, you can't hack it". According to the Radar physics, we can choose the amplitude, the frequency, the phase, the polarization, and two radiation energy supply principles, the capacitance coupling (~6m) and the inductance coupling (<1m), to code the pair of tags differently. A casual skimmer equipped with single-mode reader can not read all. We consider near-field and mid-field applications each in this paper. The near-field is at check-out counters or the convey-belt inventory involving sensitive and invariant data. The mid-field search & rescue involves not only item/person identification, but also the geo-location. If more RF power becomes cheaper & portable for longer propagation distance in the near future, then a triangulation with pair of secured readers, located at known geo-locations, could interrogate and identify items/persons and their locations in a GPS-blind environment.

  13. Theoretical and Numerical Investigation of Radiative Extinction of Diffusion Flames

    NASA Technical Reports Server (NTRS)

    Ray, Anjan

    1996-01-01

    The influence of soot radiation on diffusion flames was investigated using both analytical and numerical techniques. Soot generated in diffusion flames dominate the flame radiation over gaseous combustion products and can significantly lower the temperature of the flame. In low gravity situations there can be significant accumulation of soot and combustion products in the vicinity of the primary reaction zone owing to the absence of any convective buoyant flow. Such situations may result in substantial suppression of chemical activities in a flame, and the possibility of a radiative extinction may also be anticipated. The purpose of this work was to not only investigate the possibility of radiative extinction of a diffusion flame but also to qualitatively and quantitatively analyze the influence of soot radiation on a diffusion flame. In this study, first a hypothetical radiative loss profile of the form of a sech(sup 2) was assumed to influence a pure diffusion flame. It was observed that the reaction zone can, under certain circumstances, move through the radiative loss zone and locate itself on the fuel side of the loss zone contrary to our initial postulate. On increasing the intensity and/or width of the loss zone it was possible to extinguish the flame, and extinction plots were generated. In the presence of a convective flow, however, the movement of the temperature and reaction rate peaks indicated that the flame behavior is more complicated compared to a pure diffusional flame. A comprehensive model of soot formation, oxidation and radiation was used in a more involved analysis. The soot model of Syed, Stewart and Moss was used for soot nucleation and growth and the model of Nagle and Strickland-Constable was used for soot oxidation. The soot radiation was considered in the optically thin limit. An analysis of the flame structure revealed that the radiative loss term is countered both by the reaction term and the diffusion term. The essential balance for the soot volume fraction was found to be between the processes of soot convection and soot growth. Such a balance yielded to analytical treatment and the soot volume fraction could be expressed in the form of an integral. The integral was evaluated using two approximate methods and the results agreed very well with the numerical solutions for all cases examined.

  14. High-performing simulations of the space radiation environment for the International Space Station and Apollo Missions

    NASA Astrophysics Data System (ADS)

    Lund, Matthew Lawrence

    The space radiation environment is a significant challenge to future manned and unmanned space travels. Future missions will rely more on accurate simulations of radiation transport in space through spacecraft to predict astronaut dose and energy deposition within spacecraft electronics. The International Space Station provides long-term measurements of the radiation environment in Low Earth Orbit (LEO); however, only the Apollo missions provided dosimetry data beyond LEO. Thus dosimetry analysis for deep space missions is poorly supported with currently available data, and there is a need to develop dosimetry-predicting models for extended deep space missions. GEANT4, a Monte Carlo Method, provides a powerful toolkit in C++ for simulation of radiation transport in arbitrary media, thus including the spacecraft and space travels. The newest version of GEANT4 supports multithreading and MPI, resulting in faster distributive processing of simulations in high-performance computing clusters. This thesis introduces a new application based on GEANT4 that greatly reduces computational time using Kingspeak and Ember computational clusters at the Center for High Performance Computing (CHPC) to simulate radiation transport through full spacecraft geometry, reducing simulation time to hours instead of weeks without post simulation processing. Additionally, this thesis introduces a new set of detectors besides the historically used International Commission of Radiation Units (ICRU) spheres for calculating dose distribution, including a Thermoluminescent Detector (TLD), Tissue Equivalent Proportional Counter (TEPC), and human phantom combined with a series of new primitive scorers in GEANT4 to calculate dose equivalence based on the International Commission of Radiation Protection (ICRP) standards. The developed models in this thesis predict dose depositions in the International Space Station and during the Apollo missions showing good agreement with experimental measurements. From these models the greatest contributor to radiation dose for the Apollo missions was from Galactic Cosmic Rays due to the short time within the radiation belts. The Apollo 14 dose measurements were an order of magnitude higher compared to other Apollo missions. The GEANT4 model of the Apollo Command Module shows consistent doses due to Galactic Cosmic Rays and Radiation Belts for all missions, with a small variation in dose distribution across the capsule. The model also predicts well the dose depositions and equivalent dose values in various human organs for the International Space Station or Apollo Command Module.

  15. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  16. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  17. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  18. Training Post-9/11 Police Officers with a Counter-Terrorism Reality-Based Training Model: A Case Study

    ERIC Educational Resources Information Center

    Biddle, Christopher J.

    2013-01-01

    The purpose of this qualitative holistic multiple-case study was to identify the optimal theoretical approach for a Counter-Terrorism Reality-Based Training (CTRBT) model to train post-9/11 police officers to perform effectively in their counter-terrorism assignments. Post-9/11 police officers assigned to counter-terrorism duties are not trained…

  19. 21 CFR 310.540 - Drug products containing active ingredients offered over-the-counter (OTC) for use as stomach...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... offered over-the-counter (OTC) for use as stomach acidifiers. 310.540 Section 310.540 Food and Drugs FOOD... ingredients offered over-the-counter (OTC) for use as stomach acidifiers. (a) Betaine hydrochloride, glutamic...-counter (OTC) drug products for use as stomach acidifiers. Because of the lack of adequate data to...

  20. INVESTIGATION OF THE SUN'S X-RAYS. III. ELECTRONIC APPARATUS (in Russian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vasil'ev, B.N.; Shurigin, A.I.; Tindo, I.P.

    1963-01-01

    The electronic portion of an apparatus constructed for the investigation of soft x rays being emitted by the sun is described. The apparatus is used in geophysical rockets and in cosmic space ships and earth satellites. In the geophysical rockets two separate detection channels are employed, one for the working counters and the other for the control counters. The working counter is always directed towards the sun while the control counter is turned 15 deg away from the sun. In the second Sputnik six identical counters were used and arranged so that their line of sight was oriented along threemore » mutually perpendicular axes. In the third Sputnik the working and contour counters were distributed in a system which was self-orienting with respect to the sun. In addition, two stationary counters were enrployed; their direction with respect to the sun changed during the course of the flight. The electronic apparatus consists of the following basic components: a circuit that forms the amplitude and shape of the counter pulses, the triggering device, the separating cascade circuit, and the coding set-up. Each of these circuits is described in detail; block diagrams are shown. (TTT)« less

  1. Basic Research Needs for Countering Terrorism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stevens, W.; Michalske, T.; Trewhella, J.

    2002-03-01

    To identify connections between technology needs for countering terrorism and underlying science issues and to recommend investment strategies to increase the impact of basic research on efforts to counter terrorism.

  2. Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown.

    PubMed

    Lum, Cynthia; Kennedy, Leslie W; Sherley, Alison

    2008-02-01

    Is counter-terrorism policy evidence-based? What works, what harms, and what is unknown. One of the central concerns surrounding counter-terrorism interventions today, given the attention and money spent on them, is whether such interventions are effective. To explore this issue, we conducted a general review of terrorism literature as well as a Campbell systematic review on counter-terrorism strategies. In this article, we summarize some of our findings from these works. Overall, we found an almost complete absence of evaluation research on counter-terrorism strategies and conclude that counter-terrorism policy is not evidence-based. The findings of this review emphasise the need for government leaders, policy makers, researchers, and funding agencies to include and insist on evaluations of the effectiveness of these programs in their agendas.

  3. Hardware support for software controlled fast reconfiguration of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W.

    2013-06-18

    Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

  4. Hardware support for software controlled fast reconfiguration of performance counters

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W

    2013-09-24

    Hardware support for software controlled reconfiguration of performance counters may include a plurality of performance counters collecting one or more counts of one or more selected activities. A storage element stores data value representing a time interval, and a timer element reads the data value and detects expiration of the time interval based on the data value and generates a signal. A plurality of configuration registers stores a set of performance counter configurations. A state machine receives the signal and selects a configuration register from the plurality of configuration registers for reconfiguring the one or more performance counters.

  5. Global- to Micro-Scale Evolution of the Pinatubo Aerosol: Using Composite Data Sets to Build the Picture and Assess Consistency of Different Measurements

    NASA Technical Reports Server (NTRS)

    Russell, P. B.; Pueschel, R. F.; Livingston, J. M.; Bergstrom, R.; Lawless, James G. (Technical Monitor)

    1994-01-01

    This paper brings together experimental. evidence required to build realistic models of the global evolution of physical, chemical, and optical properties of the aerosol resulting from the 1991 Pinatubo volcanic eruption. Such models are needed to compute the effects of the aerosol on atmospheric chemistry, dynamics, radiation, and temperature. Whereas there is now a large and growing body of post-Pinatubo measurements by a variety of techniques, some results are in conflict, and a self-consistent, unified picture is needed, along with an assessment of remaining uncertainties. This paper examines data from photometers, radiometers, impactors, optical counters/sizers, and lidars operated on the ground, aircraft, balloons, and spacecraft.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rahman, Nur Aira Abd, E-mail: nur-aira@nm.gov.my; Lombigit, Lojius; Abdullah, Nor Arymaswati

    This paper presents the design of new digital radiation survey meter with LND7121 Geiger Muller tube detector and Atmega328P microcontroller. Development of the survey meter prototype is carried out on Arduino Uno platform. 16-bit Timer1 on the microcontroller is utilized as external pulse counter to produce count per second or CPS measurement. Conversion from CPS to dose rate technique is also performed by Arduino to display results in micro Sievert per hour (μSvhr{sup −1}). Conversion factor (CF) value for conversion of CPM to μSvhr{sup −1} determined from manufacturer data sheet is compared with CF obtained from calibration procedure. The surveymore » meter measurement results are found to be linear for dose rates below 3500 µSv/hr.« less

  7. MHD Flow of Sodium Alginate-Based Casson Type Nanofluid Passing Through A Porous Medium With Newtonian Heating.

    PubMed

    Khan, Arshad; Khan, Dolat; Khan, Ilyas; Ali, Farhad; Karim, Faizan Ul; Imran, Muhammad

    2018-06-05

    Casson nanofluid, unsteady flow over an isothermal vertical plate with Newtonian heating (NH) is investigated. Sodium alginate (base fluid)is taken as counter example of Casson fluid. MHD and porosity effects are considered. Effects of thermal radiation along with heat generation are examined. Sodium alginate with Silver, Titanium oxide, Copper and Aluminum oxide are added as nano particles. Initial value problem with physical boundary condition is solved by using Laplace transform method. Exact results are obtained for temperature and velocity fields. Skin-friction and Nusselt number are calculated. The obtained results are analyzed graphically for emerging flow parameters and discussed. It is bring into being that temperature and velocity profile are decreasing with increasing nano particles volume fraction.

  8. Science & Technology Review May 2006

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aufderheide III, M B

    2006-04-03

    This month's issue has the following articles: (1) Science and Technology Help the Nation Counter Terrorism--Commentary by Raymond J. Juzaitis; (2) Imagers Provide Eyes to See Gamma Rays--Gamma-ray imagers provide increased radiation detection capabilities and enhance the nation's arsenal for homeland security; (3) Protecting the Nation's Livestock--Foot-and-mouth disease could devastate America's livestock; a new assay provides a rapid means to detect it; (4) Measures for Measures--Laboratory physicists combine emissivity and reflectivity to achieve highly accurate temperature measurements of metal foils; and (5) Looping through the Lamb Shift--Livermore scientists measured a small perturbation in the spectra of highly ionized uranium--the firstmore » measurement of the two-loop Lamb shift in a bound state.« less

  9. The formation process of the He I lambda 10830 line in cool giant stars

    NASA Technical Reports Server (NTRS)

    Luttermoser, Donald G.

    1993-01-01

    The Final Report on the formation process of the He I lambda 10830 line in cool giant stars is presented. The research involves observing a sample of cool giant stars with ROSAT. These stars were selected from the list of bright stars which display He I lambda 10830 in absorption or emission and lie on the cool side of the coronal dividing line. With measured x ray fluxes or upper limits measured by the Position Sensitive Proportional Counter (PSPC), the role x rays play in the formation of this important line was investigated using the non-LTE radiative transfer code PANDORA. Hydrodynamic calculations were performed to investigate the contributions of acoustic wave heating in the formation of this line as well.

  10. Ion mobility analysis of lipoproteins

    DOEpatents

    Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA

    2007-08-21

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  11. Aerosol preparation of intact lipoproteins

    DOEpatents

    Benner, W Henry [Danville, CA; Krauss, Ronald M [Berkeley, CA; Blanche, Patricia J [Berkeley, CA

    2012-01-17

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  12. Batteryless magneto-driven portable radiac

    DOEpatents

    Waechter, D.A.; Bjarke, G.O.; Trujillo, F.; Wolf, M.A.; Umbarger, C.J.

    1984-10-19

    A hand-powerd alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Mueller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.

  13. Heat transfer from an internal combustion (Otto-cycle) engine on the surface of Mars

    NASA Technical Reports Server (NTRS)

    Gwynne, Owen

    1992-01-01

    The cooling requirements for an average car sized engine (spark-ignition, V-6, four-stroke, naturally aspirated, about 200 kg, about 100 kW) were looked at for Mars. Several modes of cooling were considered, including forced convection, exhaust, radiation and closed loop systems. The primary goal was to determine the effect of the thinner Martian atmosphere on the cooling system. The results show that there was only a 6-percent difference in the cooling requirements. This difference was due mostly to the thinner atmosphere during forced convection and the heat capacity of the exhaust. A method using a single pass counter-flow heat exchanger is suggested to offset this difference in cooling requirements.

  14. Heat transfer from an internal combustion (Otto-cycle) engine on the surface of Mars

    NASA Astrophysics Data System (ADS)

    Gwynne, Owen

    1992-05-01

    The cooling requirements for an average car sized engine (spark-ignition, V-6, four-stroke, naturally aspirated, about 200 kg, about 100 kW) were looked at for Mars. Several modes of cooling were considered, including forced convection, exhaust, radiation and closed loop systems. The primary goal was to determine the effect of the thinner Martian atmosphere on the cooling system. The results show that there was only a 6-percent difference in the cooling requirements. This difference was due mostly to the thinner atmosphere during forced convection and the heat capacity of the exhaust. A method using a single pass counter-flow heat exchanger is suggested to offset this difference in cooling requirements.

  15. Batteryless magneto-driven portable radiac

    DOEpatents

    Waechter, David A.; Bjarke, George O.; Trujillo, Faustin; Wolf, Michael A.; Umbarger, C. John

    1986-01-01

    A hand-powered alternator for generating an alternating voltage provides same through a rectifier to a high capacity capacitor which stores the resultant dc voltage and drives a voltage regulator to provide a constant low voltage output for a portable radiation detection instrument. The instrument includes a Geiger-Muller detector tube whose output is fed to a pulse detector and then through an event counter and LCD driver circuit to an LCD bar graph for visual display. An audio driver and an audio output is also provided. All circuitry used is low power so that the capacitor can be readily charged to a sufficient level to provide power for at least 30 minutes. A low voltage indicator is provided on the LCD display to indicate the need for manual recharging.

  16. 21 CFR 201.315 - Over-the-counter drugs for minor sore throats; suggested warning.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Over-the-counter drugs for minor sore throats... Drug Products § 201.315 Over-the-counter drugs for minor sore throats; suggested warning. The Food and... counter for the relief of minor irritations of the mouth or throat. It will not object to the labeling of...

  17. 21 CFR 201.315 - Over-the-counter drugs for minor sore throats; suggested warning.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 4 2011-04-01 2011-04-01 false Over-the-counter drugs for minor sore throats... Drug Products § 201.315 Over-the-counter drugs for minor sore throats; suggested warning. The Food and... counter for the relief of minor irritations of the mouth or throat. It will not object to the labeling of...

  18. Can counter-advertising reduce pre-adolescent children's susceptibility to front-of-package promotions on unhealthy foods? Experimental research.

    PubMed

    Dixon, Helen; Scully, Maree; Kelly, Bridget; Chapman, Kathy; Wakefield, Melanie

    2014-09-01

    This study aimed to test whether counter-advertisements (i.e. messages contesting industry marketing) make pre-adolescent children less susceptible to the influence of food promotions. Since children have lower media literacy levels due to their immature cognitive abilities, specific research questions explored were: (1) whether the effectiveness of counter-ads is contingent on children having understood them; and (2) whether counter-ads may be detrimental when they are misinterpreted. A between-subjects experimental design using a web-based methodology was employed. 1351 grade 5-6 students (mean age 11 years) from schools located in metropolitan Melbourne, Australia participated. Participants were randomly shown an animated web banner advertisement (counter-ad challenging front-of-package promotion or control ad) and a pair of food packages from the same product category comprising an unhealthy product featuring a front-of-package promotion (nutrient content claim or sports celebrity endorsement) and a healthier control pack without a front-of-package promotion. Responses to the assigned advertisement, choice of product (healthy versus unhealthy) and ratings of the unhealthy product and front-of-package promotion on various nutritional and image-related attributes were recorded for each child. Sixty-six percent of children who viewed a counter-ad understood its main message. These children rated the front-of-package promotion as less believable and rated the unhealthy product bearing the front-of-package promotion as less healthy compared to the control group. However, children who misunderstood the counter-ad rated the unhealthy product bearing a front-of-package promotion as more healthy and rated the front-of-package promotion more favourably than those who correctly understood the counter-ad. Counter-advertising may have unintended consequences when misunderstood. If public health organizations or government pursue counter-advertising as a strategy to reduce the negative influence of unhealthy food marketing among children, caution is needed in designing counter-ads to guard against possible contradictory effects. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Samus Counter Lifting Fixture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stredde, H.; /Fermilab

    1998-05-27

    A lifting fixture has been designed to handle the Samus counters. These counters are being removed from the D-zero area and will be transported off site for further use at another facility. This fixture is designed specifically for this particular application and will be transferred along with the counters. The future use of these counters may entail installation at a facility without access to a crane and therefore a lift fixture suitable for both crane and/or fork lift usage has been created The counters weigh approximately 3000 lbs. and have threaded rods extended through the counter at the top comersmore » for lifting. When these counters were first handled/installed these rods were used in conjunction with appropriate slings and handled by crane. The rods are secured with nuts tightened against the face of the counter. The rod thread is M16 x 2({approx}.625-inch dia.) and extends 2-inch (on average) from the face of the counter. It is this cantilevered rod that the lift fixture engages with 'C' style plates at the four top comers. The strongback portion of the lift fixture is a steel rectangular tube 8-inch (vertical) x 4-inch x .25-inch wall, 130-inch long. 1.5-inch square bars are welded perpendicular to the long axis of the rectangular tube at the appropriate lift points and the 'C' plates are fastened to these bars with 3/4-10 high strength bolts -grade 8. Two short channel sections are positioned-welded-to the bottom of the rectangular tube on 40 feet centers, which are used as locators for fork lift tines. On the top are lifting eyes for sling/crane usage and are rated at 3500 lbs. safe working load each - vertical lift only.« less

  20. Corporate Functional Management Evaluation of the LLNL Radiation Safety Organization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sygitowicz, L S

    2008-03-20

    A Corporate Assess, Improve, and Modernize review was conducted at Lawrence Livermore National Laboratory (LLNL) to evaluate the LLNL Radiation Safety Program and recommend actions to address the conditions identified in the Internal Assessment conducted July 23-25, 2007. This review confirms the findings of the Internal Assessment of the Institutional Radiation Safety Program (RSP) including the noted deficiencies and vulnerabilities to be valid. The actions recommended are a result of interviews with about 35 individuals representing senior management through the technician level. The deficiencies identified in the LLNL Internal Assessment of the Institutional Radiation Safety Program were discussed with Radiationmore » Safety personnel team leads, customers of Radiation Safety Program, DOE Livermore site office, and senior ES&H management. There are significant issues with the RSP. LLNL RSP is not an integrated, cohesive, consistently implemented program with a single authority that has the clear roll and responsibility and authority to assure radiological operations at LLNL are conducted in a safe and compliant manner. There is no institutional commitment to address the deficiencies that are identified in the internal assessment. Some of these deficiencies have been previously identified and corrective actions have not been taken or are ineffective in addressing the issues. Serious funding and staffing issues have prevented addressing previously identified issues in the Radiation Calibration Laboratory, Internal Dosimetry, Bioassay Laboratory, and the Whole Body Counter. There is a lack of technical basis documentation for the Radiation Calibration Laboratory and an inadequate QA plan that does not specify standards of work. The Radiation Safety Program lack rigor and consistency across all supported programs. The implementation of DOE Standard 1098-99 Radiological Control can be used as a tool to establish this consistency across LLNL. The establishment of a site wide ALARA Committee and administrative control levels would focus attention on improved processes. Currently LLNL issues dosimeters to a large number of employees and visitors that do not enter areas requiring dosimetry. This includes 25,000 visitor TLDs per year. Dosimeters should be issued to only those personnel who enter areas where dosimetry is required.« less

  1. Radiation Shielding of Lunar Regolith/Polyethylene Composites and Lunar Regolith/Water Mixtures

    NASA Technical Reports Server (NTRS)

    Johnson, Quincy F.; Gersey, Brad; Wilkins, Richard; Zhou, Jianren

    2011-01-01

    Space radiation is a complex mixed field of ionizing radiation that can pose hazardous risks to sophisticated electronics and humans. Mission planning for lunar exploration and long duration habitat construction will face tremendous challenges of shielding against various types of space radiation in an attempt to minimize the detrimental effects it may have on materials, electronics, and humans. In late 2009, the Lunar Crater Observation and Sensing Satellite (LCROSS) discovered that water content in lunar regolith found in certain areas on the moon can be up to 5.6 +/-2.8 weight percent (wt%) [A. Colaprete, et. al., Science, Vol. 330, 463 (2010). ]. In this work, shielding studies were performed utilizing ultra high molecular weight polyethylene (UHMWPE) and aluminum, both being standard space shielding materials, simulated lunar regolith/ polyethylene composites, and simulated lunar regolith mixed with UHMWPE particles and water. Based on the LCROSS findings, radiation shielding experiments were conducted to test for shielding efficiency of regolith/UHMWPE/water mixtures with various percentages of water to compare relative shielding characteristics of these materials. One set of radiation studies were performed using the proton synchrotron at the Loma Linda Medical University where high energy protons similar to those found on the surface of the moon can be generated. A similar experimental protocol was also used at a high energy spalation neutron source at Los Alamos Neutron Science Center (LANSCE). These experiments studied the shielding efficiency against secondary neutrons, another major component of space radiation field. In both the proton and neutron studies, shielding efficiency was determined by utilizing a tissue equivalent proportional counter (TEPC) behind various thicknesses of shielding composite panels or mixture materials. Preliminary results from these studies indicated that adding 2 wt% water to regolith particles could increase shielding of the regolith materials by about 6%. The findings may be utilized to extend the possibilities of potential candidate materials for lunar habitat structures, will potentially impact the design criteria of future human bases on the moon, and provide some guidelines for future space mission planning with respect to radiation exposure and risks posed on astronauts.

  2. Assessment of cirrus cloud and aerosol radiative effect in South-East Asia by ground-based NASA MPLNET lidar network data and CALIPSO satellite measurements

    NASA Astrophysics Data System (ADS)

    Lolli, Simone; Campbell, James R.; Lewis, Jasper R.; Welton, Ellsworth J.; Di Girolamo, Paolo; Fatkhuroyan, Fatkhuroyan; Gu, Yu; Marquis, Jared W.

    2017-10-01

    Aerosol, together with cirrus clouds, play a fundamental role in the earth-atmosphere system radiation budget, especially at tropical latitudes, where the Earth surface coverage by cirrus cloud can easily reach 70%. In this study we evaluate the combined aerosol and cirrus cloud net radiative effects in a wild and barren region like South East Asia. This part of the world is extremely vulnerable to climate change and it is source of important anthropogenic and natural aerosol emissions. The analysis has been carried out by computing cirrus cloud and aerosol net radiative effects through the Fu-Liou-Gu atmospheric radiative transfer model, adequately adapted to input lidar measurements, at surface and top-of-the atmosphere. The aerosol radiative effects were computed respectively using the retrieved lidar extinction from Cloud-Aerosol Lidar with Orthogonal Polarization in 2011 and 2012 and the lidar on-board of Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations for the South East Asia Region (27N-12S, 77E-132E) with 5° x 5° spatial resolution. To assess the cirrus cloud radiative effect, we used the ground-based Micro Pulse Lidar Network measurements at Singapore permanent observational site. Results put in evidence that strong aerosol emission areas are related on average to a net surface cooling. On the contrary, cirrus cloud radiative effect shows a net daytime positive warming of the system earth-atmosphere. This effect is weak over the ocean where the albedo is lower and never counter-balances the net cooling produced by aerosols. The net cooling is stronger in 2011, with an associated reduction in precipitations by the four of the five rain-gauges stations deployed in three regions as Sumatra, Kalimantan and Java with respect to 2012. We can speculate that aerosol emissions may be associated with lower rainfall, however some very important phenomena as El Nino Southern Oscillation , Madden-Julian Oscillation, Monsoon and Indian Dipole are not considered in the analysis.

  3. Interpretation of TEPC Measurements in Space Flights for Radiation Monitoring

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; Nikjoo, Hooshang; Dicello, John F.; Pisacane, Vincent; Cucinotta, Francis A.

    2007-01-01

    For the proper interpretation of radiation data measured in space, the results of integrated radiation transport models were compared with the tissue equivalent proportional counter (TEPC) measurements. TEPC is a simple, time-dependent approach to radiation monitoring for astronauts on board the International Space Station. Another and a newer approach to microdosimetry is the use of silicon-on-insulator (SOI) technology launched on the MidSTAR-1 mission in low Earth orbit (LEO). In the radiation protection practice, the average quality factor of a radiation field is defined as a function of linear energy transfer (LET), Qave(LET). However, TEPC measures the average quality factor as a function of the lineal energy y, Qave(y), defined as the average energy deposition in a volume divided by the average chord length of the volume. The deviation of y from LET is caused by energy straggling, delta-ray escape or entry, and nuclear fragments produced in the detector volume. The response distribution functions of the wall-less and walled TEPCs were calculated from Monte-Carlo track simulations. Using an integrated space radiation model (which includes the transport codes HZETRN and BRYNTRN, and the quantum nuclear interaction model QMSFRG) and the resultant response distribution functions from Monte-Carlo track simulations, we compared model calculations with the walled-TEPC measurements from NASA missions in LEO and made predictions for the lunar and the Mars missions. Good agreement was found for Qave(y) between the model and measured spectra from past NASA missions. The Qave(y) values for the trapped or the solar protons ranged from 1.9-2.5. This over-estimates the Qave(LET) values which ranged from 1.4-1.6. Both quantities increase with shield thickness due to nuclear fragmentation. The Qave(LET) for the complete GCR spectra was found to be 3.5-4.5, while flight TEPCs measured 2.9-3.4 for Qave(y). The GCR values are decreasing with the shield thickness. Our analysis of the measurements of TEPCs can be used for a proper interpretation of observed data of monitoring the space radiation environment.

  4. Pinatubo Aerosol Evolution: Using Composite Data Sets to Build the Global- to Micro-Scale Picture and Assess Consistency of Different Measurements

    NASA Technical Reports Server (NTRS)

    Russell, P. B.; Pueschel, R. F.; Livingston, J. M.; Bergstrom, R.; Hamill, P.

    1994-01-01

    This paper brings together experimental evidence required to build realistic models of the global evolution of physical, chemical, and optical properties of the aerosol resulting from the 1991 Pinatubo volcanic eruption. Such models are needed to compute the effects of the aerosol on atmospheric chemistry, dynamics, radiation, and temperature. Whereas there is now a large and growing body of post-Pinatubo measurements by a variety of techniques, some results are in conflict, and a self-consistent, unified picture is needed, along with an assessment of remaining uncertainties. This paper examines data from photometers, radiometers, impactors, optical counters/sizers, and lidars operated on the ground, aircraft, balloons, and spacecraft. Example data sources include: - Tracking sunphotometers and lidars at Mauna Loa Observatory (MLO) and on the DC-8 - Particle spectrometers and wire impactors on the ER-2 and DC-8 - Dustsondes (particle counters/sizers on balloons) - SAGE II, SAM II, AVHRR, CLAES, and ISAMS sensors on a variety of satellites. We assess the mutual consistency of these disparate data sets and recommend 'consensus" properties and uncertainties in the process of developing a composite data set. Recommended properties include the spatial and temporal evolution of particle chemical composition, shape, wavelength and temperature-dependent refractive index, size distribution, and optical depth spectra. Supporting references are cited and representative data shown.

  5. Pinatubo Aerosol Evolution: Using Composite Data Sets to Build the Global- To Micro-Scale Picture and Assess Consistency of Different Measurements

    NASA Technical Reports Server (NTRS)

    Russell, Philip B.; Pueschel, R. F.; Livingston, J. M.; Bergstrom, R.; Hamill, P.; Lawless, James G. (Technical Monitor)

    1994-01-01

    This paper brings together experimental evidence required to build realistic models of the global evolution of physical, chemical, and optical properties of the aerosol resulting from the 1991 Pinatubo volcanic eruption. Such models are needed to compute the effects of the aerosol on atmospheric chemistry, dynamics, radiation, and temperature. Whereas there is now a large and crowing body of post-Pinatubo measurements by a variety of techniques, some results are in conflict, and a self-consistent, unified picture is needed, along with an assessment of remaining uncertainties. This paper examines, data from photometers, radiometers, impactors, optical counter/sizers, and lidars operated on the ground, aircraft, balloons, and spacecraft. Example data sources include: (1) Tracking sunphotometers and lidars at Mauna Loa Observatory (MLO) and on the DC-8. (2) Particle spectrometers and wire impactors on the ER-2 and DC-8. (3) Dustsondes (particle counter/sizers on balloons). and (3) SAGE II, SAM II, AVHRR, CLAES, and ISAMS sensors on a variety of satellites. We assess the mutual consistency of these disparate data sets and recommend 'consensus' properties and uncertainties in the process of developing a composite data set. Recommended properties include the spatial and temporal evolution of particle chemical composition, shape, wavelength-and temperature-dependent refractive index, size distribution, and optical depth spectra. Supporting references are cited and representative data shown.

  6. Performance of the CAPRICE98 balloon-borne gas-RICH detector

    NASA Astrophysics Data System (ADS)

    Bergström, D.; Boezio, M.; Carlson, P.; Francke, T.; Grinstein, S.; Weber, N.; Suffert, M.; Hof, M.; Kremer, J.; Menn, W.; Simon, M.; Stephens, S. A.; Ambriola, M.; Bellotti, R.; Cafagna, F.; Castellano, M.; Ciacio, F.; Circella, M.; De Marzo, C.; Finetti, N.; Papini, P.; Piccardi, S.; Spillantini, P.; Bartalucci, S.; Ricci, M.; Bidoli, V.; Casolino, M.; De Pascale, M. P.; Morselli, A.; Picozza, P.; Sparvoli, R.; Barbiellini, G.; Schiavon, P.; Vacchi, A.; Zampa, N.; Mitchell, J. W.; Ormes, J. F.; Streitmatter, R. E.; Bravar, U.; Stochaj, S. J.

    2001-05-01

    A RICH counter using a gas radiator of C 4F 10 and a photosensitive MWPC with pad readout has been developed, tested in particle beam at CERN and used in the CAPRICE98 balloon-borne experiment. The MWPC was operated with a TMAE and ethane mixture at atmospheric pressure and used a cathode pad plane to give an unambiguous image of the Cherenkov light. The induced signals in the pad plane were read out using the AMPLEX chip and CRAMS. The good efficiency of the Cherenkov light collection, the efficient detection of the weak signal from single UV photons together with a low noise level in the electronics of the RICH detector, resulted in a large number of detected photoelectrons per event. For β≃1 charge one particles, an average of 12 photoelectrons per event were detected. The reconstructed Cherenkov angle of 50 mrad for a β≃1 particle had a resolution of 1.2 mrad (rms). The RICH was flown with the CAPRICE98 magnetic spectrometer and was the first RICH counter ever used in a balloon-borne experiment capable of identifying charge one particles at energies above 5 GeV. The RICH provided an identification of cosmic ray antiprotons up to the highest energies ever studied (about 50 GeV of total energy). The spectrometer was flown on 28-29 May 1998 from Fort Sumner, New Mexico, USA.

  7. Limitations of Phased Array Beamforming in Open Rotor Noise Source Imaging

    NASA Technical Reports Server (NTRS)

    Horvath, Csaba; Envia, Edmane; Podboy, Gary G.

    2013-01-01

    Phased array beamforming results of the F31/A31 historical baseline counter-rotating open rotor blade set were investigated for measurement data taken on the NASA Counter-Rotating Open Rotor Propulsion Rig in the 9- by 15-Foot Low-Speed Wind Tunnel of NASA Glenn Research Center as well as data produced using the LINPROP open rotor tone noise code. The planar microphone array was positioned broadside and parallel to the axis of the open rotor, roughly 2.3 rotor diameters away. The results provide insight as to why the apparent noise sources of the blade passing frequency tones and interaction tones appear at their nominal Mach radii instead of at the actual noise sources, even if those locations are not on the blades. Contour maps corresponding to the sound fields produced by the radiating sound waves, taken from the simulations, are used to illustrate how the interaction patterns of circumferential spinning modes of rotating coherent noise sources interact with the phased array, often giving misleading results, as the apparent sources do not always show where the actual noise sources are located. This suggests that a more sophisticated source model would be required to accurately locate the sources of each tone. The results of this study also have implications with regard to the shielding of open rotor sources by airframe empennages.

  8. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women.

    PubMed

    Leicht, Carola; Gocłowska, Małgorzata A; Van Breen, Jolien A; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women ( N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations.

  9. Counter-Stereotypes and Feminism Promote Leadership Aspirations in Highly Identified Women

    PubMed Central

    Leicht, Carola; Gocłowska, Małgorzata A.; Van Breen, Jolien A.; de Lemus, Soledad; Randsley de Moura, Georgina

    2017-01-01

    Although women who highly identify with other women are more susceptible to stereotype threat effects, women's identification might associate with greater leadership aspirations contingent on (1) counter-stereotype salience and (2) feminist identification. When gender counter-stereotypes are salient, women's identification should associate with greater leadership aspiration regardless of feminism, while when gender stereotypes are salient, women's identification would predict greater leadership aspirations contingent on a high level of feminist identification. In our study US-based women (N = 208) attended to gender stereotypic (vs. counter-stereotypic) content. We measured identification with women and identification with feminism, and, following the manipulation, leadership aspirations in an imagined work scenario. The interaction between identification with women, identification with feminism, and attention to stereotypes (vs. counter-stereotypes) significantly predicted leadership aspirations. In the counter-stereotypic condition women's identification associated with greater leadership aspirations regardless of feminist identification. In the stereotypic condition women's identification predicted leadership aspirations only at high levels of feminist identification. We conclude that salient counter-stereotypes and a strong identification with feminism may help high women identifiers increase their leadership aspirations. PMID:28626437

  10. Ti Porous Film-Supported NiCo₂S₄ Nanotubes Counter Electrode for Quantum-Dot-Sensitized Solar Cells.

    PubMed

    Deng, Jianping; Wang, Minqiang; Song, Xiaohui; Yang, Zhi; Yuan, Zhaolin

    2018-04-17

    In this paper, a novel Ti porous film-supported NiCo₂S₄ nanotube was fabricated by the acid etching and two-step hydrothermal method and then used as a counter electrode in a CdS/CdSe quantum-dot-sensitized solar cell. Measurements of the cyclic voltammetry, Tafel polarization curves, and electrochemical impedance spectroscopy of the symmetric cells revealed that compared with the conventional FTO (fluorine doped tin oxide)/Pt counter electrode, Ti porous film-supported NiCo₂S₄ nanotubes counter electrode exhibited greater electrocatalytic activity toward polysulfide electrolyte and lower charge-transfer resistance at the interface between electrolyte and counter electrode, which remarkably improved the fill factor, short-circuit current density, and power conversion efficiency of the quantum-dot-sensitized solar cell. Under illumination of one sun (100 mW/cm²), the quantum-dot-sensitized solar cell based on Ti porous film-supported NiCo₂S₄ nanotubes counter electrode achieved a power conversion efficiency of 3.14%, which is superior to the cell based on FTO/Pt counter electrode (1.3%).

  11. The counter and consultation room work explored in the Netherlands.

    PubMed

    Mobach, Mark P

    2008-08-01

    To determine the frequency and nature of conversations at the counter and of private consultations at three Dutch community pharmacies. In a purposive and convenience sample of three Dutch community pharmacies two work categories were investigated: counter work and consultation room work with self-reporting tally. The study took 6 weeks: 2 weeks at each pharmacy. The number of care related conversations and consultations emerging in the counter work and consultation room work. About 43% of all counter conversations consisted of the provision of pharmaceutical information and 72% of the consultations in the separate consultation room dealt with care related activities. However, only 18 consultations were held in this latter room: 0.4% of all reported conversations. The proportion of care related work at the counter and in the consultation room did have significant substance. There are however serious possibilities to change pharmaceutical care for the better. It is suggested that standard procedures at the counter may help increasing care related work. The presence of a separate consultation room may increase the number of consultations held in private, when combined with raising patient awareness of its existence.

  12. Counter electrodes in dye-sensitized solar cells.

    PubMed

    Wu, Jihuai; Lan, Zhang; Lin, Jianming; Huang, Miaoliang; Huang, Yunfang; Fan, Leqing; Luo, Genggeng; Lin, Yu; Xie, Yimin; Wei, Yuelin

    2017-10-02

    Dye-sensitized solar cells (DSSCs) are regarded as prospective solar cells for the next generation of photovoltaic technologies and have become research hotspots in the PV field. The counter electrode, as a crucial component of DSSCs, collects electrons from the external circuit and catalyzes the redox reduction in the electrolyte, which has a significant influence on the photovoltaic performance, long-term stability and cost of the devices. Solar cells, dye-sensitized solar cells, as well as the structure, principle, preparation and characterization of counter electrodes are mentioned in the introduction section. The next six sections discuss the counter electrodes based on transparency and flexibility, metals and alloys, carbon materials, conductive polymers, transition metal compounds, and hybrids, respectively. The special features and performance, advantages and disadvantages, preparation, characterization, mechanisms, important events and development histories of various counter electrodes are presented. In the eighth section, the development of counter electrodes is summarized with an outlook. This article panoramically reviews the counter electrodes in DSSCs, which is of great significance for enhancing the development levels of DSSCs and other photoelectrochemical devices.

  13. A Study of The Direct Aerosol Forcing At Ground Level For A Pollution Event During The Escompte Campaign

    NASA Astrophysics Data System (ADS)

    Mallet, M.; Roger, J. C.; Dubuisson, P.; Putaud, J. P.; van Dingenen, R.; Despiau, S.

    Radiative forcing by aerosol particles is one of the largest source of uncertainties in predicting climate change (IPCC, 2001). Indeed, quantitative estimates of this effect are still uncertain due to little knowledge of these atmospheric particles. Atmospheric particles influence the Earth's radiation balance both directly and indirectly. The indi- rect effect denotes the effect of aerosols acting as cloud condensation nuclei, possibly modifying cloud albedo and cloud lifetime. The direct effect is due to scattering and absorption of radiation and each of these processes depends mainly on the refractive index and the size distribution of aerosol particles. During the ESCOMPTE campaign, which took place in coastal Mediterranean area during the summer 2001, we estimated these aerosol micro-physical properties during a pollution event at two different sites. The first is an urban site (the city of Marseille), and the second is a rural area located fifty kilometers inland. The aerosol size distribution was measured with an SMPS for the particles with radii < 1 µm, and an optical counter for r > 1 µm. The chemi- cal composition (including different ionic compounds , dust, elemental and organic carbon) was deduced from chromatography analysis. The aerosol optical properties calculated from measured aerosol physical and chemical properties at ground level (from Mie theory) are used as input to a shortwave radiative transfer model. Then, this model is used to calculate the diurnally averaged direct aerosol forcing at surface and to compare this values with those measured from the ARAT aircraft and surface pyranometer during the campaign.

  14. A real-time pulsed photon dosimeter

    NASA Astrophysics Data System (ADS)

    Brown, David; Olsher, Richard H.; Eisen, Yosef; Rodriguez, Joseph F.

    1996-02-01

    Radiation sources producing short pulses of photon radiation are now widespread. Such sources include electron and proton linear accelerators, betatrons, synchrotrons, and field-emission impulse generators. It is often desirable to measure leakage and skyshine radiation from such sources in real time, on a single-pulse basis as low as 8.7 nGy (1 μR) per pulse. This paper describes the design and performance of a prototype, real-time, pulsed photon dosimeter (PPD) capable of single-pulse dose measurements over the range from 3.5 nGy to 3.5 μGy (0.4 to 400 μR). The PPD may also be operated in a multiple-pulse mode that integrates the dose from a train of radiation pulses over a 3-s period. A pulse repetition rate of up to 300 Hz is accommodated. The design is eminently suitable for packaging as a lightweight, portable, survey meter. The PPD uses a CdWO 4 scintillator optically coupled to a photodiode to generate a charge at the diode output. A pulse amplifier converts the charge to a voltage pulse. A digitizer circuit generates a burst of logic pulses whose number is proportional to the peak value of the voltage pulse. The digitizer output is recorded by a pulse counter and suitably displayed. A prototype PPD was built for testing and evaluation purposes. The performance of the PPD was evaluated with a variety of pulsed photon sources. The dynamic range, energy response, and response to multiple pulses were characterized. The experimental data confirm the viability of the PPD for pulsed photon dosimetry.

  15. Observational capabilities of solar satellite "Coronas-Photon"

    NASA Astrophysics Data System (ADS)

    Kotov, Yu.

    Coronas-Photon mission is the third satellite of the Russian Coronas program on solar activity observation The main goal of the Coronas-Photon is the study of solar hard electromagnetic radiation in the wide energy range from UV up to high energy gamma-radiation sim 2000MeV Scientific payload for solar radiation observation consists of three type of instruments 1 monitors Natalya-2M Konus-RF RT-2 Penguin-M BRM Phoka Sphin-X Sokol for spectral and timing measurements of full solar disk radiation with timing in flare burst mode up to one msec Instruments Natalya-2M Konus-RF RT-2 will cover the wide energy range of hard X-rays and soft Gamma rays 15keV to 2000MeV and will together constitute the largest area detectors ever used for solar observations Detectors of gamma-ray monitors are based on structured inorganic scintillators with energy resolution sim 5 for nuclear gamma-line band to 35 for GeV-band PSD analysis is used for gamma neutron separation for solar neutron registration T 30MeV Penguin-M has capability to measure linear polarization of hard X-rays using azimuth are measured by Compton scattering asymmetry in case of polarization of an incident flux For X-ray and EUV monitors the scintillation phoswich detectors gas proportional counter CZT assembly and Filter-covered Si-diodes are used 2 Telescope-spectrometer TESIS for imaging solar spectroscopy in X-rays with angular resolution up to 1 in three spectral lines and RT-2 CZT assembly of CZT

  16. Set of instruments for solar EUV and soft X-ray monitoring onboard satellite Coronas-Photon

    NASA Astrophysics Data System (ADS)

    Kotov, Yury; Kochemasov, Alexey; Kuzin, Sergey; Kuznetsov, Vladimir; Sylwester, Janusz; Yurov, Vitaly

    Coronas-Photon mission is the third satellite of the Russian Coronas program on solar activity observation. The main goal of the "Coronas-Photon" is the study of solar hard electromagnetic radiation in the wide energy range from UV up to high energy gamma-radiation (2000MeV). Scientific payload for solar radiation observation consists of three types of instruments: Monitors (Natalya-2M, Konus-RF, RT-2, Penguin-M, BRM, PHOKA, Sphin-X, SOKOL spectral and timing measurements of full solar disk radiation have timing in flare/burst mode up to one msec. Instruments Natalya-2M, Konus-RF, RT-2 will cover the wide energy range of hard X-rays and soft gamma-rays (15keV to 2000MeV) and will together constitute the largest area detectors ever used for solar observations. Detectors of gamma-ray monitors are based on structured inorganic scintillators. For X-ray and EUV monitors the scintillation phoswich detectors, gas proportional counter, CdZnTe assembly and filter-covered Si-diodes are used. Telescope-spectrometer TESIS for imaging solar spectroscopy in X-rays has angular resolution up to 1arcsec in three spectral lines. Satellite platform and scientific payload is under construction to be launched in autumn 2008. Satellite orbit is circular with initial height 550km and inclination 82.5degrees. Accuracy of the spacecraft orientation to the Sun is better 3arcmin. In the report the capability of PHOKA, SphinX, SOKOL and TESIS as well as the observation program are described and discussed.

  17. Method for the prediction of the effective dose equivalent to the crew of the International Space Station

    NASA Astrophysics Data System (ADS)

    El-Jaby, Samy; Tomi, Leena; Sihver, Lembit; Sato, Tatsuhiko; Richardson, Richard B.; Lewis, Brent J.

    2014-03-01

    This paper describes a methodology for assessing the pre-mission exposure of space crew aboard the International Space Station (ISS) in terms of an effective dose equivalent. In this approach, the PHITS Monte Carlo code was used to assess the particle transport of galactic cosmic radiation (GCR) and trapped radiation for solar maximum and minimum conditions through an aluminum shield thickness. From these predicted spectra, and using fluence-to-dose conversion factors, a scaling ratio of the effective dose equivalent rate to the ICRU ambient dose equivalent rate at a 10 mm depth was determined. Only contributions from secondary neutrons, protons, and alpha particles were considered in this analysis. Measurements made with a tissue equivalent proportional counter (TEPC) located at Service Module panel 327, as captured through a semi-empirical correlation in the ISSCREM code, where then scaled using this conversion factor for prediction of the effective dose equivalent. This analysis shows that at this location within the service module, the total effective dose equivalent is 10-30% less than the total TEPC dose equivalent. Approximately 75-85% of the effective dose equivalent is derived from the GCR. This methodology provides an opportunity for pre-flight predictions of the effective dose equivalent and therefore offers a means to assess the health risks of radiation exposure on ISS flight crew.

  18. ISS Observations of the Trapped Proton Anisotropic Effect: A Comparison with Model Calculations

    NASA Astrophysics Data System (ADS)

    Dachev, T.; Atwell, W.; Semones, E.; Tomov, B.; Reddell, B.

    Space radiation measurements were made on the International Space Station (ISS) with the Bulgarian Liulin-E094 instrument, which contains 4 Mobile Dosimetry Unit (MDU), and the NASA Tissue Equivalent Proportional Counter (TEPC) during 2001. Four MDUs were placed at fixed locations: one unit (MDU #1) in the ISS "Unity" Node-1 and three (MDU #2-#4) units were located in the US Laboratory module. The MDU #2 and the TEPC were located in the US Laboratory module Human Research Facility (rack #1, port side). Space radiation flight measurements were obtained during the time period May 11 - July 26, 2001. In this paper we discuss the flight observed asymmetries in different detectors on the ascending and descending parts of the ISS orbits. The differences are described by the development of a shielding model using combinatorial geometry and 3-D visualization and the orientation and placement of the five detectors at the locations within the ISS. Shielding distributions were generated for the combined ISS and detector shielding models. The AP8MAX and AE8MAX trapped radiation models were used to compute the daily absorbed dose for the five detectors and are compared with the flight measurements. In addition, the trapped proton anisotropy (East-West effect) was computed for the individual passes through the South Atlantic Anomaly based on the Badhwar-Konradi anisotropy model.

  19. Basic design of a multi wire proportional counter using Garfield++ for ILSF

    NASA Astrophysics Data System (ADS)

    Ghahremani Gol, M.; Ashrafi, S.; Rahighi, J.

    2016-12-01

    The Iranian Light Source Facility (ILSF) is a new 3 GeV third generation synchrotron radiation facility in Middle East, which at the time being is in its design stage. An important aspect for the scientific success of this new source will be the availability of well adapted detectors. Position-sensitive X-ray detectors have played an important role in synchrotron radiation X-ray experiments for many years and are still in use. An operational one-dimensional multiwire position sensitive detector with delay line readout produced by ILSF showed a position resolution of 230 μm. In this paper, we introduce a 2-D position sensitive gas detector based on a multiwire proportional chamber which will be used in small/wide angle scattering and diffraction experiments with synchrotron radiation at the ILSF. The parameters of its components, including the gas filling, gas pressure, temperature, the geometry of anode and cathodes planes as well as the expected performance of the designed system will be described in the following. For the design and the simulation of MWPC the Elmer and Garfield++ codes have been employed. We have built and tested a MWPC as a prototype at ILSF. The results obtained so far show a good position sensing. After primary test the detector has been optimized and is now ready for test at Elettra.

  20. Prescription Drugs, Over-the-Counter Drugs, Supplements and Herbal Products

    MedlinePlus

    ... at risk? Zika virus and pregnancy Folic acid Medicine safety and pregnancy Birth defects prevention Learn how ... the-counter drugs, supplements and herbal products Prescription drugs, over-the-counter drugs, supplements and herbal products ...

  1. Effect of Transitioning from Standard Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering

    DTIC Science & Technology

    2016-04-01

    Reference Material 2806b for Light Obscuration Particle Countering April 2016 UNCLASSIFIED UNCLASSIFIED Joel Schmitigal 27809 Standard Form 298 (Rev...Standard Reference Material 2806b for Light Obscuration Particle Countering 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6...Reference Material 2806a to Standard Reference Material 2806b for Light Obscuration Particle Countering Joel Schmitigal Force Projection

  2. Using DMA for copying performance counter data to memory

    DOEpatents

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    A device for copying performance counter data includes hardware path that connects a direct memory access (DMA) unit to a plurality of hardware performance counters and a memory device. Software prepares an injection packet for the DMA unit to perform copying, while the software can perform other tasks. In one aspect, the software that prepares the injection packet runs on a processing core other than the core that gathers the hardware performance counter data.

  3. Counter traction makes endoscopic submucosal dissection easier.

    PubMed

    Oyama, Tsuneo

    2012-11-01

    Poor counter traction and poor field of vision make endoscopic submucosal dissection (ESD) difficult. Good counter traction allows dissections to be performed more quickly and safely. Position change, which utilizes gravity, is the simplest method to create a clear field of vision. It is useful especially for esophageal and colon ESD. The second easiest method is clip with line method. Counter traction made by clip with line accomplishes the creation of a clear field of vision and suitable counter traction thereby making ESD more efficient and safe. The author published this method in 2002. The name ESD was not established in those days; the name cutting endoscopic mucosal resection (EMR) or EMR with hook knife was used. The other traction methods such as external grasping forceps, internal traction, double channel scope, and double scopes method are introduced in this paper. A good strategy for creating counter traction makes ESD easier.

  4. Counter-Rotatable Fan Gas Turbine Engine with Axial Flow Positive Displacement Worm Gas Generator

    NASA Technical Reports Server (NTRS)

    Giffin, Rollin George (Inventor); Murrow, Kurt David (Inventor); Fakunle, Oladapo (Inventor)

    2014-01-01

    A counter-rotatable fan turbine engine includes a counter-rotatable fan section, a worm gas generator, and a low pressure turbine to power the counter-rotatable fan section. The low pressure turbine maybe counter-rotatable or have a single direction of rotation in which case it powers the counter-rotatable fan section through a gearbox. The gas generator has inner and outer bodies having offset inner and outer axes extending through first, second, and third sections of a core assembly. At least one of the bodies is rotatable about its axis. The inner and outer bodies have intermeshed inner and outer helical blades wound about the inner and outer axes and extending radially outwardly and inwardly respectively. The helical blades have first, second, and third twist slopes in the first, second, and third sections respectively. A combustor section extends through at least a portion of the second section.

  5. Alcohol counter-advertising and the media. A review of recent research.

    PubMed

    Agostinelli, Gina; Grube, Joel W

    2002-01-01

    Counter-advertising commonly is used to balance the effects that alcohol advertising may have on alcohol consumption and alcohol-related problems. Such measures can take the form of print or broadcast advertisements (e.g., public service announcements [PSAs]) as well as product warning labels. The effectiveness of both types of counter-advertising is reviewed using the Elaboration Likelihood Model as a theoretical framework. For print and broadcast counter-advertisements, such factors as their emotional appeal and the credibility of the source, as well as audience factors, can influence their effectiveness. Further, brewer-sponsored counter-advertisements are evaluated and received differently than are the more conventional PSA counter-advertisements. For warning labels, both the content and design of the label influence their effectiveness, as do audience factors. The effectiveness of those labels is evaluated in terms of the extent to which they impact cognitive and affective processes as well as drinking behavior.

  6. Over-the-Counter Medicines

    MedlinePlus

    Over-the-counter (OTC) medicines are drugs you can buy without a prescription. Some OTC medicines relieve aches, pains and itches. Some prevent or cure ... the Food and Drug Administration decides whether a medicine is safe enough to sell over-the-counter. ...

  7. High use of over-the-counter analgesic; possible warnings of reduced quality of life in adolescents - a qualitative study.

    PubMed

    Skarstein, Siv; Lagerløv, Per; Kvarme, Lisbeth Gravdal; Helseth, Sølvi

    2016-01-01

    Use of over-the-counter analgesics among adolescents has increased markedly. High consumption of over-the-counter analgesics among adolescents is associated with frequent pain, lower self-esteem, reduced sleep, lower educational ambition, binge drinking, higher caffeine consumption, and part-time employment. Knowledge about life experiences of adolescents who frequently use over-the-counter analgesics may be useful to prevent health problems. The purpose of the study was to increase knowledge about adolescents who suffer from frequent pain and have a high consumption of over-the-counter analgesics. A qualitative study, employing one-on-one, in-depth interviews using a thematic interview guide. Data were collected in Norway in 2013-2014. Three boys and sixteen girls; aged 14-16 years, who continuously consumed over-the-counter analgesics were recruited from ten high schools in urban and suburban districts. Candidate participants were excluded if they were medically diagnosed with an acute or chronic illness, requiring extended use of over-the-counter analgesics within the last year. The interviews were taped, transcribed and analysed as text according to Kvale's three contexts of interpretation: self-understanding, common sense and theory. All participants disclosed unresolved physical and psychosocial distress characterized as pain. Frequent pain from various body parts made everyday life challenging. Methods of pain self-appraisal and over-the-counter analgesics use often mimicked maternal patterns. Participants reported being raised under unpredictable circumstances that contributed to long lasting family conflicts and peer-group problems. Participants wanted to feel appreciated and to be socially and academically successful. However, pain reduced their ability to manage everyday life, hampered experienced possibilities for success, and made social settings difficult. Childhood experiences influence how adolescents experience pain and use over-the-counter analgesics. Coping with difficult situations or attempting to mask symptoms with over-the-counter analgesics can perpetuate and amplify underlying problems. High consumption of over-the-counter analgesics and frequent pain may be warning signs of adolescents with possible health threatening conditions and reduced quality of life. These adolescent might be in need of support from school nurses and General Practitioners. This study identifies new perspectives that may lead to novel approaches to identify, guide, and support adolescents with frequent pain and high consumption of over-the-counter analgesics.

  8. Study on Radiation Condition in DAMPE Orbit by Analyzing the Engineering Data of BGO Calorimeter

    NASA Astrophysics Data System (ADS)

    Feng, Changqing; Liu, Shubin; Zhang, Yunlong; Ma, Siyuan

    2016-07-01

    The DAMPE (DArk Matter Particle Explorer) is a scientific satellite which was successfully launched into a 500 Km sun-synchronous orbit, on December 17th, 2015, from the Jiuquan Satellite Launch Center of China. The major scientific objectives of the DAMPE mission are primary cosmic ray, gamma ray astronomy and dark matter particles, by observing high energy primary cosmic rays, especially positrons/electrons and gamma rays with an energy range from 5 GeV to 10 TeV. The BGO calorimeter is a critical sub-detector of DAMPE payload, for measuring the energy of cosmic particles, distinguishing positrons/electrons and gamma rays from hadron background, and providing trigger information. It utilizes 308 BGO (Bismuth Germanate Oxide) crystal logs with the size of 2.5cm*2.5cm*60cm for each log, to form a total absorption electromagnetic calorimeter. All the BGO logs are stacked in 14 layers, with each layer consisting of 22 BGO crystal logs and each log is viewed by two Hamamatsu R5610A PMTs (photomultiplier tubes), from both sides respectively. In order to achieve a large dynamic range, each PMT base incorporates a three dynode (2, 5, 8) pick off, which results in 616 PMTs and 1848 signal channels. The readout electronics system, which consists of 16 FEE (Front End Electronics) modules, was developed. Its main functions are based on the Flash-based FPGA (Field Programmable Gate Array) chip and low power, 32-channel VA160 and VATA160 ASICs (Application Specific Integrated Circuits) for precisely measuring the charge of PMT signals and providing "hit" signals as well. The hit signals are sent to the trigger module of PDPU (Payload Data Process Unit) and the hit rates of each layer is real-timely recorded by counters and packed into the engineering data, which directly reflect the flux of particles which fly into or pass through the detectors. In order to mitigate the SEU (Single Event Upset) effect in radioactive space environment, certain protecting methods, such as TMR (Triple Modular Redundancy) and CRC (Cyclic Redundancy Check) for some critical registers in FPGA logic was adopted. To mitigate the SEL (Single Event Latch-up) effect for the ASICs chips, a protecting solution by monitoring the current of VA160/VATA160 chips are applied. All the SEU and SEL events are recorded by counters and transmitted to ground station in the form of engineering data. The information of hit rates, and the SEU and SEL counters in the engineering data can be used to evaluate the radiation condition and its variations in DAMPE orbit. The preliminary results are introduced in this paper, which is based on the engineering data in the first six months after launching.

  9. HIGH VOLTAGE GENERATOR

    DOEpatents

    Zito, G.V.

    1959-04-21

    This patent relates to high voltage supply circuits adapted for providing operating voltages for GeigerMueller counter tubes, and is especially directed to an arrangement for maintaining uniform voltage under changing conditions of operation. In the usual power supply arrangement for counter tubes the counter voltage is taken from across the power supply output capacitor. If the count rate exceeds the current delivering capaciiy of the capacitor, the capacitor voltage will drop, decreasing the counter voltage. The present invention provides a multivibrator which has its output voltage controlled by a signal proportional to the counting rate. As the counting rate increases beyond the current delivering capacity of the capacitor, the rectified voltage output from the multivibrator is increased to maintain uniform counter voltage.

  10. Hispanic youth involvement in over-the-counter drug use: parent, peer, and school factors.

    PubMed

    Vidourek, Rebecca A; King, Keith A; Fehr, Sara K

    2014-01-01

    Research on substance use among Hispanic youth is lacking. The purpose of this study was to examine over-the-counter drug use among Hispanic youth. Of Hispanic youth, 23.9% used an over-the-counter drug for the purpose of getting high. Involvement in prosocial behaviors was correlated with decreased over-the-counter use for females and high school students. Involvement in risky behaviors increased the risk of use for males, females, junior high school students, and high school students. Significant differences were found based on parent, peer, teacher, and school factors. Prevention and intervention programs should address over-the-counter drug use among Hispanic youth.

  11. Measuring the radioactivity of drinking water with the liquid counters M2H in combination with contamination meters IM 4457

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vanhemmen, J.J.; Vanhoek, L.P.; Aten, J.B.T.

    1976-01-01

    The relationship between the meter indications and the radioactivity of fission products in drinking water for the combination contamination meter IM 4457 and liquid counter M2H was investigated. The experimental setup is presented, the efficiency of the liquid counter for a mixture of fission products is briefly dealt with, and the use of the combination counter/meter in the field is discussed.

  12. The remote controlling technique based on the serial port for SR-620 universal counter

    NASA Astrophysics Data System (ADS)

    Su, Jian-Feng; Chen, Shu-Fang; Li, Xiao-Hui; Wu, Hai-Tao; Bian, Yu-Jing

    2004-12-01

    The function of SR-620 universal counter and the remote work mode are introduced, and the remote controlling technique for the counter is analysed. A method to realize the remote controlling via the serial port for the counter is demonstrated, in which an ActiveX control is used. Besides, some points for attention in debugging are discussed based on the experience, and a case of program running for measuring time-delay is presented.

  13. Normative and counter-normative stress messages and symptom reporting: implications for health promotion and a methodological artefact for stress research.

    PubMed

    Ferguson, Eamonn; Lawrence, Claire

    2013-05-01

    There is increasing use of counter-normative health messages (i.e., evidence-based health information about cause-effect relationships that run counter to shared normative beliefs, e.g., stress can lead to personal growth). The current studies examine the effect of normative and counter-normative messages about stress on levels of symptom reporting. Predictions are derived from reactance, social comparison, and self-enhancement theories. Two studies focus on the development of the messages, and two experimental studies examine the effect of manipulating normative and counter-normative messages on symptom reports. The final study controls for mere-measurement effects and explores the role of stress process variables (appraisals and coping). Exposure to a normative message (stress causes ill health) results in reduced symptom reporting compared to a counter-normative message (stress provides challenge, growth, and development) and control groups. The results suggest that people may use symptom reporting strategically to indicate coping. Based on the argument that beliefs about stress and health are stored as mental models, the theoretical associations derived from stress theory are only observed when a normative message is presented. Counter-normative stress messages may carry no tangible benefits compared to normative messages. Some stress research may suffer from inherent methodological bias when normative information is provided in information and consent sheets. Statement of contribution What is already known on this subject? At present, nothing is known about counter-normative health messages, despite the fact that they are becoming widely used as a public intervention. What does this study add? A clear operational definition of counter-normative messages. A test of three competing theories for counter-normative messages that focus of the stress-symptom link. Demonstrating for the first time, that in the domain of stress and health, counter-normative messages are at best ineffective. Demonstrating for the first time that only when the stress-coping-symptom links are made explicit do the theoretical associations observed in the literature emerge. This may be a potential methodological artefact in stress research that needs to be controlled. © 2013 The British Psychological Society.

  14. Kinematic and stellar population properties of the counter-rotating components in the S0 galaxy NGC 1366

    NASA Astrophysics Data System (ADS)

    Morelli, L.; Pizzella, A.; Coccato, L.; Corsini, E. M.; Dalla Bontà, E.; Buson, L. M.; Ivanov, V. D.; Pagotto, I.; Pompei, E.; Rocco, M.

    2017-04-01

    Context. Many disk galaxies host two extended stellar components that rotate in opposite directions. The analysis of the stellar populations of the counter-rotating components provides constraints on the environmental and internal processes that drive their formation. Aims: The S0 NGC 1366 in the Fornax cluster is known to host a stellar component that is kinematically decoupled from the main body of the galaxy. Here we successfully separated the two counter-rotating stellar components to independently measure the kinematics and properties of their stellar populations. Methods: We performed a spectroscopic decomposition of the spectrum obtained along the galaxy major axis and separated the relative contribution of the two counter-rotating stellar components and of the ionized-gas component. We measured the line-strength indices of the two counter-rotating stellar components and modeled each of them with single stellar population models that account for the α/Fe overabundance. Results: We found that the counter-rotating stellar component is younger, has nearly the same metallicity, and is less α/Fe enhanced than the corotating component. Unlike most of the counter-rotating galaxies, the ionized gas detected in NGC 1366 is neither associated with the counter-rotating stellar component nor with the main galaxy body. On the contrary, it has a disordered distribution and a disturbed kinematics with multiple velocity components observed along the minor axis of the galaxy. Conclusions: The different properties of the counter-rotating stellar components and the kinematic peculiarities of the ionized gas suggest that NGC 1366 is at an intermediate stage of the acquisition process, building the counter-rotating components with some gas clouds still falling onto the galaxy. Based on observations made with ESO Telescopes at the La Silla-Paranal Observatory under programmes 075.B-0794 and 077.B-0767.

  15. In situ single cell detection via microfluidic magnetic bead assay

    PubMed Central

    KC, Pawan; Zhang, Ge; Zhe, Jiang

    2017-01-01

    We present a single cell detection device based on magnetic bead assay and micro Coulter counters. This device consists of two successive micro Coulter counters, coupled with a high gradient magnetic field generated by an external magnet. The device can identify single cells in terms of the transit time difference of the cell through the two micro Coulter counters. Target cells are conjugated with magnetic beads via specific antibody and antigen binding. A target cell traveling through the two Coulter counters interacts with the magnetic field, and have a longer transit time at the 1st counter than that at the 2nd counter. In comparison, a non-target cell has no interaction with the magnetic field, and hence has nearly the same transit times through the two counters. Each cell passing through the two counters generates two consecutive voltage pulses one after the other; the pulse widths and magnitudes indicating the cell’s transit times through the counters and the cell’s size respectively. Thus, by measuring the pulse widths (transit times) of each cell through the two counters, each single target cell can be differentiated from non-target cells even if they have similar sizes. We experimentally proved that the target human umbilical vein endothelial cells (HUVECs) and non-target rat adipose-derived stem cells (rASCs) have significant different transit time distribution, from which we can determine the recognition regions for both cell groups quantitatively. We further demonstrated that within a mixed cell population of rASCs and HUVECs, HUVECs can be detected in situ and the measured HUVECs ratios agree well with the pre-set ratios. With the simple device structure and easy sample preparation, this method is expected to enable single cell detection in a continuous flow and can be applied to facilitate general cell detection applications such as stem cell identification and enumeration. PMID:28222140

  16. In situ single cell detection via microfluidic magnetic bead assay.

    PubMed

    Liu, Fan; Kc, Pawan; Zhang, Ge; Zhe, Jiang

    2017-01-01

    We present a single cell detection device based on magnetic bead assay and micro Coulter counters. This device consists of two successive micro Coulter counters, coupled with a high gradient magnetic field generated by an external magnet. The device can identify single cells in terms of the transit time difference of the cell through the two micro Coulter counters. Target cells are conjugated with magnetic beads via specific antibody and antigen binding. A target cell traveling through the two Coulter counters interacts with the magnetic field, and have a longer transit time at the 1st counter than that at the 2nd counter. In comparison, a non-target cell has no interaction with the magnetic field, and hence has nearly the same transit times through the two counters. Each cell passing through the two counters generates two consecutive voltage pulses one after the other; the pulse widths and magnitudes indicating the cell's transit times through the counters and the cell's size respectively. Thus, by measuring the pulse widths (transit times) of each cell through the two counters, each single target cell can be differentiated from non-target cells even if they have similar sizes. We experimentally proved that the target human umbilical vein endothelial cells (HUVECs) and non-target rat adipose-derived stem cells (rASCs) have significant different transit time distribution, from which we can determine the recognition regions for both cell groups quantitatively. We further demonstrated that within a mixed cell population of rASCs and HUVECs, HUVECs can be detected in situ and the measured HUVECs ratios agree well with the pre-set ratios. With the simple device structure and easy sample preparation, this method is expected to enable single cell detection in a continuous flow and can be applied to facilitate general cell detection applications such as stem cell identification and enumeration.

  17. The effect of the use of a counter-torque device on the abutment-implant complex.

    PubMed

    Lang, L A; May, K B; Wang, R F

    1999-04-01

    Little is known about the condition of the abutment-screw joint before loading, after the development of the preload. This study examined the tightening force transmitted to the implant with and without the use of a counter-torque device during the tightening of the abutment screw. Forty Brânemark implants and 10 CeraOne, Estheticone, Procera, and AurAdapt abutments formed the experimental populations. Samples in each group were further divided into 2 groups, 1 group was tightened with a torque controller without the use of a counter-torque device, whereas the other used the counter-torque device. Samples were positioned in a special holder within the grips of a Tohnichi BTG-6 torque gauge for measuring transmitted forces. There were significant differences (P =. 0001) in the tightening forces transmitted to the implant with and without the use of a counter-torque device when tightening the abutment screws. An average of 91% of the recommended preload tightening torque was transmitted to the implant-bone interface in the absence of a counter-torque device. In all abutment systems, less than 10% of the recommended preload tightening torque was transmitted to the implant when the counter-torque device was used.

  18. Four pi-recoil proportional counter used as neutron spectrometer

    NASA Technical Reports Server (NTRS)

    Bennett, E. F.

    1968-01-01

    Study considers problems encountered in using 4 pi-recoil counters for neutron spectra measurement. Emphasis is placed on calibration, shape discrimination, variation of W, the average energy loss per ion pair, and the effects of differentiation on the intrinsic counter resolution.

  19. Counter-diabatic driving for Dirac dynamics

    NASA Astrophysics Data System (ADS)

    Fan, Qi-Zhen; Cheng, Xiao-Hang; Chen, Xi

    2018-03-01

    In this paper, we investigate the fast quantum control of Dirac equation dynamics by counter-diabatic driving, sharing the concept of shortcut to adiabaticity. We systematically calculate the counter-diabatic terms in different Dirac systems, like graphene and trapped ions. Specially, the fast and robust population inversion processes are achieved in Dirac system, taking into account the quantum simulation with trapped ions. In addition, the population transfer between two bands can be suppressed by counter-diabatic driving in graphene system, which might have potential applications in opt-electric devices.

  20. Configurable memory system and method for providing atomic counting operations in a memory device

    DOEpatents

    Bellofatto, Ralph E.; Gara, Alan G.; Giampapa, Mark E.; Ohmacht, Martin

    2010-09-14

    A memory system and method for providing atomic memory-based counter operations to operating systems and applications that make most efficient use of counter-backing memory and virtual and physical address space, while simplifying operating system memory management, and enabling the counter-backing memory to be used for purposes other than counter-backing storage when desired. The encoding and address decoding enabled by the invention provides all this functionality through a combination of software and hardware.

  1. Multiple channel programmable coincidence counter

    DOEpatents

    Arnone, Gaetano J.

    1990-01-01

    A programmable digital coincidence counter having multiple channels and featuring minimal dead time. Neutron detectors supply electrical pulses to a synchronizing circuit which in turn inputs derandomized pulses to an adding circuit. A random access memory circuit connected as a programmable length shift register receives and shifts the sum of the pulses, and outputs to a serializer. A counter is input by the adding circuit and downcounted by the seralizer, one pulse at a time. The decoded contents of the counter after each decrement is output to scalers.

  2. Analyzing the Operational Factors of Space, Force, and Time in United States Southern Command’s Counter Drug / Counter Narcoterrorism Mission

    DTIC Science & Technology

    2010-05-03

    countries by the President. Of the 20 nations listed as meeting the criteria for 2008, 12 are found in SOUTHCOM’s AOR: The Bahamas, Bolivia , Brazil...Venezuela and Bolivia ), making them harder to catch on their way to Mexico or, increasingly, overseas.” 26 (Italics added for emphasis) Beyond pure...Southern Command. Command Strategy 2018 . Miami, FL: December, 2008. ------. “Counter Drug / Counter Narcoterrorism.” www.southcom.mil/AppsSC/pages

  3. U.S. and Department of Defense Building Partnership Capacity and Counter/Anti-Corruption: A Symbiotic Relationship or One at Odds

    DTIC Science & Technology

    2016-02-16

    AIR WAR COLLEGE AIR UNIVERSITY U.S. AND DEPARTMENT OF DEFENSE BUILDING PARTNERSHIP CAPACITY AND COUNTER/ANTI-CORRUPTION: A SYMBIOTIC ...Extortion,” DoD BPC and counter/anti-corruption have resulted in both a symbiotic relationship and one at odds. This uncomfortable dichotomy has led to...extraversion as “Soft Extortion” have all led DoD BPC and counter/anti-corruption efforts into a relationship that is both symbiotic and one at odds

  4. Hardware enabled performance counters with support for operating system context switching

    DOEpatents

    Salapura, Valentina; Wisniewski, Robert W.

    2015-06-30

    A device for supporting hardware enabled performance counters with support for context switching include a plurality of performance counters operable to collect information associated with one or more computer system related activities, a first register operable to store a memory address, a second register operable to store a mode indication, and a state machine operable to read the second register and cause the plurality of performance counters to copy the information to memory area indicated by the memory address based on the mode indication.

  5. Implementing Badhwar-O'Neill Galactic Cosmic Ray Model for the Analysis of Space Radiation Exposure

    NASA Technical Reports Server (NTRS)

    Kim, Myung-Hee Y.; O'Neill, Patrick M.; Slaba, Tony C.

    2014-01-01

    For the analysis of radiation risks to astronauts and planning exploratory space missions, accurate energy spectrum of galactic cosmic radiation (GCR) is necessary. Characterization of the ionizing radiation environment is challenging because the interplanetary plasma and radiation fields are modulated by solar disturbances and the radiation doses received by astronauts in interplanetary space are likewise influenced. A model of the Badhwar-O'Neill 2011 (BO11) GCR environment, which is represented by GCR deceleration potential theta, has been derived by utilizing all of the GCR measurements from balloons, satellites, and the newer NASA Advanced Composition Explorer (ACE). In the BO11 model, the solar modulation level is derived from the mean international sunspot numbers with time-delay, which has been calibrated with actual flight instrument measurements to produce better GCR flux data fit during solar minima. GCR fluxes provided by the BO11 model were compared with various spacecraft measurements at 1 AU, and further comparisons were made for the tissue equivalent proportional counters measurements at low Earth orbits using the high-charge and energy transport (HZETRN) code and various GCR models. For the comparison of the absorbed dose and dose equivalent calculations with the measurements by Radiation Assessment Detector (RAD) at Gale crater on Mars, the intensities and energies of GCR entering the heliosphere were calculated by using the BO11 model, which accounts for time-dependent attenuation of the local interstellar spectrum of each element. The BO11 model, which has emphasized for the last 24 solar minima, showed in relatively good agreement with the RAD data for the first 200 sols, but it was resulted in to be less well during near the solar maximum of solar cycle 24 due to subtleties in the changing heliospheric conditions. By performing the error analysis of the BO11 model and the optimization in reducing overall uncertainty, the resultant BO13 model corrects the fit at solar maxima as well as being accurate at solar minima. The BO13 model is implemented to the NASA Space Cancer Risk model for the assessment of radiation risks. Overall cumulative probability distribution of solar modulation parameters represents the percentile rank of the average interplanetary GCR environment, and the probabilistic radiation risks can be assessed for various levels of GCR environment to support mission design and operational planning for future manned space exploration missions.

  6. Transitioning the second-generation antihistamines to over-the-counter status: a cost-effectiveness analysis.

    PubMed

    Sullivan, Patrick W; Follin, Sheryl L; Nichol, Michael B

    2003-12-01

    A U.S. Food and Drug Administration advisory committee deemed the second-generation antihistamines (SGA) safe for over-the-counter use against the preliminary opposition of the manufacturers. As a result, loratadine is now available over-the-counter. First-generation antihistamines (FGA) are associated with an increased risk of unintentional injuries, fatalities, and reduced productivity. Access to SGA over-the-counter could result in decreased use of FGA, thereby reducing deleterious outcomes. The societal impact of transitioning this class of medications from prescription to over-the-counter status has important policy implications. To examine the cost-effectiveness of transitioning SGA to over-the-counter status from a societal perspective. A simulation model of the decision to transition SGA to over-the-counter status was compared with retaining prescription-only status for a hypothetical cohort of individuals with allergic rhinitis in the United States. Estimates of costs and effectiveness were obtained from the medical literature and national surveys. Sensitivity analysis was performed using a second-order Monte Carlo simulation. Discounted, quality-adjusted life-years saved as a result of amelioration of allergic rhinitis symptoms and avoidance of motor vehicle, occupational, public and home injuries and fatalities; discounted direct and indirect costs. Availability of SGA over-the-counter was associated with annual savings of 4 billion dollars (2.4-5.3 billion dollars) or 100 dollars (64-137 dollars) per allergic rhinitis sufferer and 135,061 time-discounted quality-adjusted life years (84,913-191,802). The sensitivity analysis provides evidence in support of these results. Making SGA available over-the-counter is both cost-saving and more effective for society, largely as a result of reduced adverse outcomes associated with FGA-induced sedation. Further study is needed to determine the differential impact on specific vulnerable populations.

  7. Changing the status of drugs from prescription to over-the-counter availability.

    PubMed

    Brass, E P

    2001-09-13

    The availability of drugs on an over-the-counter basis, including those previously available only by prescription, provides patients with improved access to effective therapies. Removal of the requirement for prescriptions saves both the health care professional and the patient time. However, the overall effect on health care costs is complex. One such effect may be that costs shift from third-party payers to patients. In addition, short-term cost savings may be offset over the long term by problems due to inappropriate use or suboptimal therapy. Optimal therapy with an over-the-counter drug requires that the consumer diagnose the underlying condition correctly and use the drug in a manner that minimizes risk. Assessment of the ability of patients to use drugs in this manner is a critical component of the regulatory review of over-the-counter drugs. The available data arouse the concern that without the supervision of a health care professional, some patients may not be able to use over-the-counter drugs appropriately for certain diagnoses or chronic conditions or in high-risk situations. On the other hand, the widespread use of over-the-counter aspirin on a long-term basis for cardiovascular-risk reduction illustrates the potential value of increased drug availability for long-term therapy. Advances in technology may facilitate the growth of over-the-counter drug therapy. For example, the wide availability and acceptance of reliable methods for measuring serum cholesterol in nonmedical settings may eventually contribute to the safety and effectiveness of over-the-counter treatments for hyperlipidemia. Thus, the future promises increases in the number of drugs available over the counter and in the variety of indications for their use.

  8. Neurobehavioral Effects of Space Radiation on Psychomotor Vigilance Tests

    NASA Astrophysics Data System (ADS)

    Hienz, Robert; Davis, Catherine; Weed, Michael; Guida, Peter; Gooden, Virginia; Brady, Joseph; Roma, Peter

    Neurobehavioral Effects of Space Radiation on Psychomotor Vigilance Tests INTRODUCTION Risk assessment of the biological consequences of living in the space radiation environment represents one of the highest priority areas of NASA radiation research. Of critical importance is the need for a risk assessment of damage to the central nervous system (CNS) leading to functional cognitive/behavioral changes during long-term space missions, and the development of effective shielding or biological countermeasures to such risks. The present research focuses on the use of an animal model that employs neurobehavioral tests identical or homologous to those currently in use in human models of risk assessment by U.S. agencies such as the Depart-ment of Defense and Federal Aviation and Federal Railroad Administrations for monitoring performance and estimating accident risks associated with such variables as fatigue and/or alcohol or drug abuse. As a first approximation for establishing human risk assessments due to exposure to space radiation, the present work provides animal performance data obtained with the rPVT (rat Psychomotor Vigilance Test), an animal analog of the human PVT that is currently employed for human risk assessments via quantification of sustained attention (e.g., 'vigilance' or 'readiness to perform' tasks). Ground-based studies indicate that radiation can induce neurobehavioral changes in rodents, including impaired performance on motor tasks and deficits in spatial learning and memory. The present study is testing the hypothesis that radiation exposure impairs motor function, performance accuracy, vigilance, motivation, and memory in adult male rats. METHODS The psychomotor vigilance test (PVT) was originally developed as a human cognitive neurobe-havioral assay for tracking the temporally dynamic changes in sustained attention, and has also been used to track changes in circadian rhythm. In humans the test requires responding to a small, bright-red-light stimulus (LED-digital counter) as soon as the stimulus appears, which stops the stimulus counter and displays the reaction time for each trial in milliseconds for a 1-sec period. Simple to perform, the PVT has only very minor learning effects, is widely used in human risk assessments in operational environments, and has been recently developed and adopted for use on the ISS for astronauts as a "self test" to provide performance feedback, detect changes in alertness, prevent errors, and manage fatigue from sleep loss, circadian dis-ruption, and high workload requirements. A rodent version of the PVT, the rPVT, has been developed and demonstrated to track the same types of performance variables as the human PVT -i.e., general motor function and speed, fine motor control, inhibitory control ("impul-sivity"), timing, selective attention, motivation, and basic sensory function. Five cohorts of 16 rats each (total N = 80) were trained on the rPVT, exported to BNL for head-only radiation exposure (0, 25, 50, 100, and 200 cGy protons @ 150 MeV/n), then returned to Johns Hopkins for follow-up testing. RESULTS The rPVT was readily learned by all rats and required as little as 5-7 days of training to acquire baseline performance levels. Following irradiation, performances in the rPVT were disrupted at exposure levels of 50, 100, and 200 cGy, showing a consistent, significant increase (i.e., slowing) in reaction times and increased lapses in responding, both indicative of a decrease in sustained attention. Additionally, premature responses showed consistent increases at the higher radiation levels. None of these changes were observed in the non-exposed control animals. Over this same time period, no significant changes were observed in discrimination accuracy, motivation (as indicated by trials completed), or food intake. SUMMARY AND CONCLUSIONS The results of these experiments demonstrate the sensitivity of tests such as the rPVT for assessing the effects of head-only space radiation on cognitive neurobehavioral function. Expo-sure to protons at as little as 50 cGy produce highly specific effects on vigilance that include impaired attention and motor function (i.e., slowed reaction times, increased lapses in atten-tion, and increased premature responding). Such deficits could significantly impact routine performances in operational environments during lunar and Mars missions, and also negatively affect post-mission adjustment upon return to Earth.

  9. SILAR deposition of nickel sulfide counter electrode for application in quantum dot sensitized solar cell

    NASA Astrophysics Data System (ADS)

    Singh, Navjot; Siwatch, Poonam; Arora, Anmol; Sharma, Jadab; Tripathi, S. K.

    2018-05-01

    Quantum Dot Sensitized Solar Cells are a likely replacement for Silicon-based solar cells. Counter electrodes are a fundamental aspect of QDSSC's performance. NiS being a less expensive material is a decent choice for the purpose. In this paper, we have discussed the synthesis of NiS by Successive Ionic Layer Adsorption Reaction. Optical, Crystallographic and Electrical studies have been presented. Electrical studies of the device with NiS counter electrode is compared with characteristics of the device with CNTs as the counter electrode. SILAR method is easy and less time to consume than chemical bath deposition or any other method. Results show the success of NiS synthesized by SILAR method as the counter electrode.

  10. Characteristics of a high pressure gas proportional counter filled with xenon

    NASA Technical Reports Server (NTRS)

    Sakurai, H.; Ramsey, B. D.

    1991-01-01

    The characteristics of a conventional cylindrical geometry proportional counter filled with high pressure xenon gas up to 10 atm. were fundamentally investigated for use as a detector in hard X-ray astronomy. With a 2 percent methane gas mixture the energy resolutions at 10 atm. were 9.8 percent and 7.3 percent for 22 keV and 60 keV X-rays, respectively. From calculations of the Townsend ionization coefficient, it is shown that proportional counters at high pressure operate at weaker reduced electric field than low pressure counters. The characteristics of a parallel grid proportional counter at low pressure showed similar pressure dependence. It is suggested that this is the fundamental reason for the degradation of resolution observed with increasing pressure.

  11. Top-down and Bottom-up aerosol-cloud-closure: towards understanding sources of unvertainty in deriving cloud radiative flux

    NASA Astrophysics Data System (ADS)

    Sanchez, K.; Roberts, G.; Calmer, R.; Nicoll, K.; Hashimshoni, E.; Rosenfeld, D.; Ovadnevaite, J.; Preissler, J.; Ceburnis, D.; O'Dowd, C. D. D.; Russell, L. M.

    2017-12-01

    Top-down and bottom-up aerosol-cloud shortwave radiative flux closures were conducted at the Mace Head atmospheric research station in Galway, Ireland in August 2015. Instrument platforms include ground-based, unmanned aerial vehicles (UAV), and satellite measurements of aerosols, clouds and meteorological variables. The ground-based and airborne measurements of aerosol size distributions and cloud condensation nuclei (CCN) concentration were used to initiate a 1D microphysical aerosol-cloud parcel model (ACPM). UAVs were equipped for a specific science mission, with an optical particle counter for aerosol distribution profiles, a cloud sensor to measure cloud extinction, or a 5-hole probe for 3D wind vectors. These are the first UAV measurements at Mace Head. ACPM simulations are compared to in-situ cloud extinction measurements from UAVs to quantify closure in terms of cloud shortwave radiative flux. Two out of seven cases exhibit sub-adiabatic vertical temperature profiles within the cloud, which suggests that entrainment processes affect cloud microphysical properties and lead to an overestimate of simulated cloud shortwave radiative flux. Including an entrainment parameterization and explicitly calculating the entrainment fraction in the ACPM simulations both improved cloud-top radiative closure. Entrainment reduced the difference between simulated and observation-derived cloud-top shortwave radiative flux (δRF) by between 25 W m-2 and 60 W m-2. After accounting for entrainment, satellite-derived cloud droplet number concentrations (CDNC) were within 30% of simulated CDNC. In cases with a well-mixed boundary layer, δRF is no greater than 20 W m-2 after accounting for cloud-top entrainment, and up to 50 W m-2 when entrainment is not taken into account. In cases with a decoupled boundary layer, cloud microphysical properties are inconsistent with ground-based aerosol measurements, as expected, and δRF is as high as 88 W m-2, even high (> 30 W m-2) after accounting for cloud-top entrainment. This work demonstrates the need to take in-situ measurements of aerosol properties for cases where the boundary layer is decoupled as well as consider cloud-top entrainment to accurately model stratocumulus cloud radiative flux.

  12. Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy.

    PubMed

    Wang, Xudong; Charlton, Michael A; Esquivel, Carlos; Eng, Tony Y; Li, Ying; Papanikolaou, Nikos

    2013-09-01

    To evaluate the neutron and photon dose equivalent rates at the treatment vault entrance (Hn,D and HG), and to study the secondary radiation to the patient in GRID therapy. The radiation activation on the grid was studied. A Varian Clinac 23EX accelerator was working at 18 MV mode with a grid manufactured by .decimal, Inc. The Hn,D and HG were measured using an Andersson-Braun neutron REM meter, and a Geiger Müller counter. The radiation activation on the grid was measured after the irradiation with an ion chamber γ-ray survey meter. The secondary radiation dose equivalent to patient was evaluated by etched track detectors and OSL detectors on a RANDO(®) phantom. Within the measurement uncertainty, there is no significant difference between the Hn,D and HG with and without a grid. However, the neutron dose equivalent to the patient with the grid is, on average, 35.3% lower than that without the grid when using the same field size and the same amount of monitor unit. The photon dose equivalent to the patient with the grid is, on average, 44.9% lower. The measured average half-life of the radiation activation in the grid is 12.0 (± 0.9) min. The activation can be categorized into a fast decay component and a slow decay component with half-lives of 3.4 (± 1.6) min and 15.3 (± 4.0) min, respectively. There was no detectable radioactive contamination found on the surface of the grid through a wipe test. This work indicates that there is no significant change of the Hn,D and HG in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam delivery is suggested.

  13. Top-down and Bottom-up aerosol-cloud-closure: towards understanding sources of unvertainty in deriving cloud radiative flux

    NASA Astrophysics Data System (ADS)

    Sanchez, K.; Roberts, G.; Calmer, R.; Nicoll, K.; Hashimshoni, E.; Rosenfeld, D.; Ovadnevaite, J.; Preissler, J.; Ceburnis, D.; O'Dowd, C. D. D.; Russell, L. M.

    2016-12-01

    Top-down and bottom-up aerosol-cloud shortwave radiative flux closures were conducted at the Mace Head atmospheric research station in Galway, Ireland in August 2015. Instrument platforms include ground-based, unmanned aerial vehicles (UAV), and satellite measurements of aerosols, clouds and meteorological variables. The ground-based and airborne measurements of aerosol size distributions and cloud condensation nuclei (CCN) concentration were used to initiate a 1D microphysical aerosol-cloud parcel model (ACPM). UAVs were equipped for a specific science mission, with an optical particle counter for aerosol distribution profiles, a cloud sensor to measure cloud extinction, or a 5-hole probe for 3D wind vectors. These are the first UAV measurements at Mace Head. ACPM simulations are compared to in-situ cloud extinction measurements from UAVs to quantify closure in terms of cloud shortwave radiative flux. Two out of seven cases exhibit sub-adiabatic vertical temperature profiles within the cloud, which suggests that entrainment processes affect cloud microphysical properties and lead to an overestimate of simulated cloud shortwave radiative flux. Including an entrainment parameterization and explicitly calculating the entrainment fraction in the ACPM simulations both improved cloud-top radiative closure. Entrainment reduced the difference between simulated and observation-derived cloud-top shortwave radiative flux (δRF) by between 25 W m-2 and 60 W m-2. After accounting for entrainment, satellite-derived cloud droplet number concentrations (CDNC) were within 30% of simulated CDNC. In cases with a well-mixed boundary layer, δRF is no greater than 20 W m-2 after accounting for cloud-top entrainment, and up to 50 W m-2 when entrainment is not taken into account. In cases with a decoupled boundary layer, cloud microphysical properties are inconsistent with ground-based aerosol measurements, as expected, and δRF is as high as 88 W m-2, even high (> 30 W m-2) after accounting for cloud-top entrainment. This work demonstrates the need to take in-situ measurements of aerosol properties for cases where the boundary layer is decoupled as well as consider cloud-top entrainment to accurately model stratocumulus cloud radiative flux.

  14. Progress in alternative neutron detection to address the helium-3 shortage

    NASA Astrophysics Data System (ADS)

    Kouzes, Richard T.; Lintereur, Azaree T.; Siciliano, Edward R.

    2015-06-01

    One of the main uses for 3He is in gas proportional counters for neutron detection. Such detectors are used at neutron scattering science facilities and in radiation portal monitors deployed for homeland security and non-proliferation applications. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, lung imaging, for targets in nuclear research, and for basic research in condensed matter physics. The supply of 3He comes entirely from the decay of tritium produced for nuclear weapons in the U.S. and Russia. Due to the large increase in use of 3He for science and homeland security (since 2002), the supply could no longer meet the demand. This has led to the development of a number of alternative neutron detection schemes.

  15. Induction of Micronuclei in Human Fibroblasts from the Los Alamos High Energy Neutron Beam

    NASA Technical Reports Server (NTRS)

    Cox, Bradley

    2009-01-01

    The space radiation field includes a broad spectrum of high energy neutrons. Interactions between these neutrons and a spacecraft, or other material, significantly contribute to the dose equivalent for astronauts. The 15 degree beam line in the Weapons Neutron Research beam at Los Alamos Nuclear Science Center generates a neutron spectrum relatively similar to that seen in space. Human foreskin fibroblast (AG1522) samples were irradiated behind 0 to 20 cm of water equivalent shielding. The cells were exposed to either a 0.05 or 0.2 Gy entrance dose. Following irradiation, micronuclei were counted to see how the water shield affects the beam and its damage to cell nuclei. Micronuclei induction was then compared with dose equivalent data provided from a tissue equivalent proportional counter.

  16. Potential Uses of Deep Space Cooling for Exploration Missions

    NASA Technical Reports Server (NTRS)

    Chambliss, Joe; Sweterlitsch, Jeff; Swickrath, Micahel J.

    2012-01-01

    Nearly all exploration missions envisioned by NASA provide the capability to view deep space and thus to reject heat to a very low temperature environment. Environmental sink temperatures approach as low as 4 Kelvin providing a natural capability to support separation and heat rejection processes that would otherwise be power and hardware intensive in terrestrial applications. For example, radiative heat transfer can be harnessed to cryogenically remove atmospheric contaminants such as carbon dioxide (CO2). Long duration differential temperatures on sunlit versus shadowed sides of the vehicle could be used to drive thermoelectric power generation. Rejection of heat from cryogenic propellant could counter temperature increases thus avoiding the need to vent propellants. These potential uses of deep space cooling will be addressed in this paper with the benefits and practical considerations of such approaches.

  17. Determining the risk of cardiovascular disease using ion mobility of lipoproteins

    DOEpatents

    Benner, W. Henry; Krauss, Ronald M.; Blanche, Patricia J.

    2010-05-11

    A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kouzes, Richard T.; Lintereur, Azaree T.; Siciliano, Edward R.

    One of the main uses for 3He is in gas proportional counters for neutron detection. Such detectors are used at neutron scattering science facilities and in radiation portal monitors deployed for homeland security and non-proliferation applications. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, lung imaging, for targets in nuclear research, and for basic research in condensed matter physics. The supply of 3He comes entirely from the decay of tritium produced for nuclear weapons in the U.S. and Russia. Due to the large increase in use of 3He for science and homeland securitymore » (since 2002), the supply has dwindled, and can no longer meet the demand. This has led to the development of a number of alternative neutron detection schemes.« less

  19. Single Crystal Casting with Fluidized Carbon Bed Cooling: A Process Innovation for Quality Improvement and Cost Reduction

    NASA Astrophysics Data System (ADS)

    Hofmeister, M.; Franke, M. M.; Koerner, C.; Singer, R. F.

    2017-12-01

    Superalloy gas turbine blades are being produced by investment casting and directional solidification. A new process, Fluidized Carbon Bed Cooling (FCBC), has been developed and is now being optimized in a prototype casting unit with 10 kg pouring weight. In early test runs with still rather simple mold cluster geometries, a reduction of the primary dendrite arm spacing of around 40 pct compared to the standard radiation cooling process (HRS) could be demonstrated. The improvement is mainly attributed to higher temperature gradients driving solidification, made possible by a functioning Dynamic Baffle. Compared to earlier development efforts in the literature, contamination of the melt and damage to the equipment are avoided using carbon-based fluidized bed materials and the so-called "counter pressure concept."

  20. On amplifications of photonuclear neutron flux in thunderstorm atmosphere and possibility of detecting them

    NASA Astrophysics Data System (ADS)

    Babich, L. P.; Bochkov, E. I.; Kutsyk, I. M.; Zalyalov, A. N.

    2013-05-01

    The reliability of communications reporting observations of neutron flux enhancements in thunderstorm atmosphere is analyzed. The analysis is motivated by the fact that the employed gas-discharge counters on the basis of reactions 3He( n, p)3H and 10B( n; 4He, γ)7Li detect not only neutrons but any penetrating radiations. Photonuclear reactions are capable of accounting for the possible amplifications of neutron flux in thunder-storm atmosphere since in correlation with thunderstorms γ-ray flashes were repeatedly observed with spectra extending high above the threshold of photonuclear reactions in air. By numerical simulations, it was demonstrated that γ-ray pulses detected in thunderstorm atmosphere are capable of generating photonuclear neutrons in numbers sufficient to be detected even at sea level.

Top