Sample records for critical measures methods

  1. A Review of Treatment Adherence Measurement Methods

    ERIC Educational Resources Information Center

    Schoenwald, Sonja K.; Garland, Ann F.

    2013-01-01

    Fidelity measurement is critical for testing the effectiveness and implementation in practice of psychosocial interventions. Adherence is a critical component of fidelity. The purposes of this review were to catalogue adherence measurement methods and assess existing evidence for the valid and reliable use of the scores that they generate and the…

  2. Effective Instruction and Assessment Methods That Lead to Gains in Critical Thinking as Measured by the Critical Thinking Assessment Test (CAT)

    ERIC Educational Resources Information Center

    Leming, Katie P.

    2016-01-01

    Previous qualitative research on educational practices designed to improve critical thinking has relied on anecdotal or student self-reports of gains in critical thinking. Unfortunately, student self-report data have been found to be unreliable proxies for measuring critical thinking gains. Therefore, in the current interpretivist study, five…

  3. Evaluating critical thinking in clinical practice.

    PubMed

    Oermann, M H

    1997-01-01

    Although much has been written about measurement instruments for evaluating critical thinking in nursing, this article describes clinical evaluation strategies for critical thinking. Five methods are discussed: 1) observation of students in practice; 2) questions for critical thinking, including Socratic questioning; 3) conferences; 4) problem-solving strategies; and 5) written assignments. These methods provide a means of evaluating students' critical thinking within the context of clinical practice.

  4. Apparatus and method for measuring critical current properties of a coated conductor

    DOEpatents

    Mueller, Fred M [Los Alamos, NM; Haenisch, Jens [Dresden, DE

    2012-07-24

    The transverse critical-current uniformity in a superconducting tape was determined using a magnetic knife apparatus. A critical current I.sub.c distribution and transverse critical current density J.sub.c distribution in YBCO coated conductors was measured nondestructively with high resolution using a magnetic knife apparatus. The method utilizes the strong depression of J.sub.c in applied magnetic fields. A narrow region of low, including zero, magnetic field in a surrounding higher field is moved transversely across a sample of coated conductor. This reveals the critical current density distribution. A Fourier series inversion process was used to determine the transverse J.sub.c distribution in the sample.

  5. Using the case study teaching method to promote college students' critical thinking skills

    NASA Astrophysics Data System (ADS)

    Terry, David Richard

    2007-12-01

    The purpose of this study was to examine general and domain-specific critical thinking skills in college students, particularly ways in which these skills might be increased through the use of the case study method of teaching. General critical thinking skills were measured using the Watson-Glaser Critical Thinking Appraisal (WGCTA) Short Form, a forty-item paper-and-pencil test designed to measure important abilities involved in critical thinking, including inference, recognition of assumptions, deduction, interpretation, and evaluation of arguments. The ability to identify claims and support those claims with evidence is also an important aspect of critical thinking. I developed a new instrument, the Claim and Evidence Assessment Tool (CEAT), to measure these skills in a domain-specific manner. Forty undergraduate students in a general science course for non-science majors at a small two-year college in the northeastern United States experienced positive changes in general critical thinking according to results obtained using the Watson-Glaser Critical Thinking Appraisal (WGCTA). In addition, the students showed cumulative improvement in their ability to identify claims and evidence, as measured by the Claim and Evidence Assessment Tool (CEAT). Mean score on the WGCTA improved from 22.15 +/- 4.59 to 23.48 +/- 4.24 (out of 40), and the mean CEAT score increased from 14.98 +/- 3.28 to 16.20 +/- 3.08 (out of 24). These increases were modest but statistically and educationally significant. No differences in claim and evidence identification were found between students who learned about specific biology topics using the case study method of instruction and those who were engaged in more traditional instruction, and the students' ability to identify claims and evidence and their factual knowledge showed little if any correlation. The results of this research were inconclusive regarding whether or not the case study teaching method promotes college students' general or domain-specific critical thinking skills, and future research addressing this issue should probably utilize larger sample sizes and a pretest-posttest randomized experimental design.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Metz, Lori A.; Friese, Judah I.; Finn, Erin C.

    Critical assemblies provide one method of achieving a fast neutron spectrum that is close to a 235U fission-energy neutron spectrum for nuclear data measurements. Previous work has demonstrated the use of a natural boron carbide capsule for spectral-tailoring in a mixed spectrum reactor as an alternate and complementary method for performing fission-energy neutron experiments. Previous fission products measurements showed that the neutron spectrum achievable with natural boron carbide was not as hard as what can be achieved with critical assemblies. New measurements performed with the Washington State University TRIGA reactor using a boron carbide capsule 96% enriched in 10B formore » irradiations resulted in a neutron spectrum very similar to a critical assembly and a pure 235U fission spectrum. The current work describes an experiment involving a highly-enriched uranium target irradiated under the new 10B4C capsule. Fission product yields were measured following radiochemical separations and are presented here. Reactor dosimetry measurements for characterizing neutron spectra and fluence for the enriched boron carbide capsule and critical assemblies are also discussed.« less

  7. Definitions and methods of cost assessment: an intensivist's guide. ESICM section on health research and outcome working group on cost effectiveness.

    PubMed

    Jegers, M; Edbrooke, D L; Hibbert, C L; Chalfin, D B; Burchardi, H

    2002-06-01

    To define the different types of costs incurred in the care of critically ill patients and to describe some of the most commonly used methods for measuring and allocating these costs. Literature review. Definitions for opportunity, direct and indirect, fixed, variable, marginal, and total costs are described and interpreted in the context of the critical care setting. Two main methods of costing are described: the 'top-down' and 'bottom-up' methods together with a number of cost proxies, such as the use of weighted hospital days, diagnosis-related groups, severity and activity scores, and effective costs per survivor. The assessment and allocation of costs to critically ill patients is complex and as a result of the different definitions and methods used, meaningful comparisons between studies are plagued with difficulty. When undertaking a study looking to measure costs, it is important to state: (a) the aim of the cost assessment study; (b) the perspective (point of view); (c) the type of costs that need to be measured; and (d) the time span of assessment. By being explicit about the rationale of the study and the methods used, it is hoped that the results of economic evaluations will be better understood, and hence implemented within the critical care setting.

  8. Direct measurement of intrinsic critical strain and internal strain in barrier films

    NASA Astrophysics Data System (ADS)

    Vellinga, W. P.; De Hosson, J. Th. M.; Bouten, P. C. P.

    2011-08-01

    Resistance measurements during uniaxial tensile deformation of very thin (10 nm) conducting oxide films deposited on 150 nm SiN films on polyethylene naphthalate are discussed. It is first shown that certain characteristics of resistance versus strain curves are representative for the fracture behavior of the SiN film and not for that of the thin conducting oxide film. Subsequently, it is shown that the hysteresis in curves of resistance as a function of strain offers a way to directly measure the intrinsic critical strain of the SiN film without the need to determine internal strains from independent (curvature) measurements that rely on knowledge of moduli and geometry. The method should be applicable, in general, to measure intrinsic critical strain and residual strains of thin brittle films on polymers. Advantages and limitations of the method are discussed.

  9. Evaluation of tools used to measure critical thinking development in nursing and midwifery undergraduate students: a systematic review.

    PubMed

    Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary

    2015-07-01

    Well developed critical thinking skills are essential for nursing and midwifery practices. The development of students' higher-order cognitive abilities, such as critical thinking, is also well recognised in nursing and midwifery education. Measurement of critical thinking development is important to demonstrate change over time and effectiveness of teaching strategies. To evaluate tools designed to measure critical thinking in nursing and midwifery undergraduate students. The following six databases were searched and resulted in the retrieval of 1191 papers: CINAHL, Ovid Medline, ERIC, Informit, PsycINFO and Scopus. After screening for inclusion, each paper was evaluated using the Critical Appraisal Skills Programme Tool. Thirty-four studies met the inclusion criteria and quality appraisal. Sixteen different tools that measure critical thinking were reviewed for reliability and validity and extent to which the domains of critical thinking were evident. Sixty percent of studies utilised one of four standardised commercially available measures of critical thinking. Reliability and validity were not consistently reported and there was a variation in reliability across studies that used the same measure. Of the remaining studies using different tools, there was also limited reporting of reliability making it difficult to assess internal consistency and potential applicability of measures across settings. Discipline specific instruments to measure critical thinking in nursing and midwifery are required, specifically tools that measure the application of critical thinking to practise. Given that critical thinking development occurs over an extended period, measurement needs to be repeated and multiple methods of measurement used over time. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  10. The application of hazard analysis and critical control points and risk management in the preparation of anti-cancer drugs.

    PubMed

    Bonan, Brigitte; Martelli, Nicolas; Berhoune, Malik; Maestroni, Marie-Laure; Havard, Laurent; Prognon, Patrice

    2009-02-01

    To apply the Hazard analysis and Critical Control Points method to the preparation of anti-cancer drugs. To identify critical control points in our cancer chemotherapy process and to propose control measures and corrective actions to manage these processes. The Hazard Analysis and Critical Control Points application began in January 2004 in our centralized chemotherapy compounding unit. From October 2004 to August 2005, monitoring of the process nonconformities was performed to assess the method. According to the Hazard Analysis and Critical Control Points method, a multidisciplinary team was formed to describe and assess the cancer chemotherapy process. This team listed all of the critical points and calculated their risk indexes according to their frequency of occurrence, their severity and their detectability. The team defined monitoring, control measures and corrective actions for each identified risk. Finally, over a 10-month period, pharmacists reported each non-conformity of the process in a follow-up document. Our team described 11 steps in the cancer chemotherapy process. The team identified 39 critical control points, including 11 of higher importance with a high-risk index. Over 10 months, 16,647 preparations were performed; 1225 nonconformities were reported during this same period. The Hazard Analysis and Critical Control Points method is relevant when it is used to target a specific process such as the preparation of anti-cancer drugs. This method helped us to focus on the production steps, which can have a critical influence on product quality, and led us to improve our process.

  11. Efficacy of teaching methods used to develop critical thinking in nursing and midwifery undergraduate students: A systematic review of the literature.

    PubMed

    Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary

    2016-05-01

    The value and importance of incorporating strategies that promote critical thinking in nursing and midwifery undergraduate programmes are well documented. However, relatively little is known about the effectiveness of teaching strategies in promoting CT. Evaluating effectiveness is important to promote 'best practise' in teaching. To evaluate the efficacy of teaching methods used to develop critical thinking skills in nursing and midwifery undergraduate students. The following six databases; CINAHL, Ovid Medline, ERIC, Informit, PsycINFO and Scopus were searched and resulted in the retrieval of 1315 papers. After screening for inclusion, each paper was evaluated using the Critical Appraisal Skills Programme tool. Twenty-eight studies met the inclusion criteria and quality appraisal. Twelve different teaching interventions were tested in 8 countries. Results varied, with little consistency across studies using the same type of intervention or outcome tool. Sixteen tools were used to measure the efficacy of teaching in developing critical thinking. Seventeen studies identified a significant increase in critical thinking, while nine studies found no increases, and two found unexplained decreases in CT when using a similar educational intervention. Whilst this review aimed to identify effective teaching strategies that promote and develop critical thinking, flaws in methodology and outcome measures contributed to inconsistent findings. The continued use of generalised CT tools is unlikely to help identify appropriate teaching methods that will improve CT abilities of midwifery and nursing students and prepare them for practise. The review was limited to empirical studies published in English that used measures of critical thinking with midwifery and nursing students. Discipline specific strategies and tools that measure students' abilities to apply CT in practise are needed. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  12. Measurements and calculations of transport AC loss in second generation high temperature superconducting pancake coils

    NASA Astrophysics Data System (ADS)

    Yuan, Weijia; Coombs, T. A.; Kim, Jae-Ho; Han Kim, Chul; Kvitkovic, Jozef; Pamidi, Sastry

    2011-12-01

    Theoretical and experimental AC loss data on a superconducting pancake coil wound using second generation (2 G) conductors are presented. An anisotropic critical state model is used to calculate critical current and the AC losses of a superconducting pancake coil. In the coil there are two regions, the critical state region and the subcritical region. The model assumes that in the subcritical region the flux lines are parallel to the tape wide face. AC losses of the superconducting pancake coil are calculated using this model. Both calorimetric and electrical techniques were used to measure AC losses in the coil. The calorimetric method is based on measuring the boil-off rate of liquid nitrogen. The electric method used a compensation circuit to eliminate the inductive component to measure the loss voltage of the coil. The experimental results are consistent with the theoretical calculations thus validating the anisotropic critical state model for loss estimations in the superconducting pancake coil.

  13. Noncontact Measurement Of Critical Current In Superconductor

    NASA Technical Reports Server (NTRS)

    Israelsson, Ulf E.; Strayer, Donald M.

    1992-01-01

    Critical current measured indirectly via flux-compression technique. Magnetic flux compressed into gap between superconductive hollow cylinder and superconductive rod when rod inserted in hole in cylinder. Hall-effect probe measures flux density before and after compression. Method does not involve any electrical contact with superconductor. Therefore, does not cause resistive heating and consequent premature loss of superconductivity.

  14. Comparison of pulsed Doppler and thermodilution methods for measuring cardiac output in critically ill patients.

    PubMed

    Donovan, K D; Dobb, G J; Newman, M A; Hockings, B E; Ireland, M

    1987-09-01

    We obtained 145 consecutive cardiac output measurements in 38 critically ill patients, using the invasive thermodilution and the noninvasive pulsed Doppler methods. The mean thermodilution cardiac output (TDCO) was 5.7 +/- 1.87 L/min and the mean pulsed Doppler cardiac output (PDCO) was 5.16 +/- 1.66 L/min. The mean difference between the two measurements was 0.51 L/min with an SD greater than 1.6 L/min, reflecting the scattering of results. The overall correlation coefficient was .58. The intercepts were large and the regression equation some way from the line of equal values (TDCO = 2.28 + 0.66 PDCO). When the results were analyzed according to diagnosis or by group experience, there were some differences in the bias of the estimate; however, the SD of the difference between methods was greater than one liter/min in all groups. Thus, the pulsed Doppler method failed to estimate accurately TDCO in critically ill patients.

  15. Demagnetizing fields of crystallites and a method for measuring the thermodynamic fields of quasi-single-crystal and polycrystalline thin YBa{sub 2}Cu{sub 3}O{sub 7-x} disks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rostami, Kh. R.

    The role of the demagnetizing fields of crystallites in HTSC samples is studied. An increase in the crystallite size is shown to suppress the intra-and intercrystalline critical currents of the sample in lower fields. The demagnetizing fields of crystallites are shown to be one of the main causes of the fact that the Bean model is invalid for HTSC samples. A method is proposed to measure the thermodynamic field of a superconductor; this method allows the first thermodynamic critical magnetic fields of the sample and its crystallites and 'subcrystallites' to be measured with a high accuracy. The first thermodynamic criticalmore » magnetic fields are used to estimate the critical current density J{sub c} of the sample, crystallites, and subcrystallites.« less

  16. Collective Leadership Measurement for the U.S. Army

    DTIC Science & Technology

    2014-03-01

    methods employed were adapted from standard texts on survey research methods (e.g., Podsakoff, MacKenzie, Lee, & Podsakoff, 2003; Shadish, Cook...members of the research team, as well as procedures for interviews in standard research methods texts (e.g., Campion, Palmer, & Campion, 1997; Latham...critical incident protocol was based on procedures for critical incidents in standard research methods texts (e.g., Flanagan, 1954; Lowenberg, 1979

  17. Critical current density measurement of striated multifilament-coated conductors using a scanning Hall probe microscope

    NASA Astrophysics Data System (ADS)

    Li, Xiao-Fen; Kochat, Mehdi; Majkic, Goran; Selvamanickam, Venkat

    2016-08-01

    In this paper the authors succeeded in measuring the critical current density ({J}{{c}}) of multifilament-coated conductors (CCs) with thin filaments as low as 0.25 mm using the scanning hall probe microscope (SHPM) technique. A new iterative method of data analysis is developed to make the calculation of {J}{{c}} for thin filaments possible, even without a very small scan distance. The authors also discussed in detail the advantage and limitation of the iterative method using both simulation and experiment results. The results of the new method correspond well with the traditional fast Fourier transform method where this is still applicable. However, the new method is applicable for the filamentized CCs in much wider measurement conditions such as with thin filament and a large scan distance, thus overcoming the barrier for application of the SHPM technique on {J}{{c}} measurement of long filamentized CCs with narrow filaments.

  18. Allometric method to estimate leaf area index for row crops

    USDA-ARS?s Scientific Manuscript database

    Leaf area index (LAI) is critical for predicting plant metabolism, biomass production, evapotranspiration, and greenhouse gas sequestration, but direct LAI measurements are difficult and labor intensive. Several methods are available to measure LAI indirectly or calculate LAI using allometric method...

  19. Sensitivity study and parameter optimization of OCD tool for 14nm finFET process

    NASA Astrophysics Data System (ADS)

    Zhang, Zhensheng; Chen, Huiping; Cheng, Shiqiu; Zhan, Yunkun; Huang, Kun; Shi, Yaoming; Xu, Yiping

    2016-03-01

    Optical critical dimension (OCD) measurement has been widely demonstrated as an essential metrology method for monitoring advanced IC process in the technology node of 90 nm and beyond. However, the rapidly shrunk critical dimensions of the semiconductor devices and the increasing complexity of the manufacturing process bring more challenges to OCD. The measurement precision of OCD technology highly relies on the optical hardware configuration, spectral types, and inherently interactions between the incidence of light and various materials with various topological structures, therefore sensitivity analysis and parameter optimization are very critical in the OCD applications. This paper presents a method for seeking the optimum sensitive measurement configuration to enhance the metrology precision and reduce the noise impact to the greatest extent. In this work, the sensitivity of different types of spectra with a series of hardware configurations of incidence angles and azimuth angles were investigated. The optimum hardware measurement configuration and spectrum parameter can be identified. The FinFET structures in the technology node of 14 nm were constructed to validate the algorithm. This method provides guidance to estimate the measurement precision before measuring actual device features and will be beneficial for OCD hardware configuration.

  20. Methods for improved forewarning of critical events across multiple data channels

    DOEpatents

    Hively, Lee M [Philadelphia, TN

    2007-04-24

    This disclosed invention concerns improvements in forewarning of critical events via phase-space dissimilarity analysis of data from mechanical devices, electrical devices, biomedical data, and other physical processes. First, a single channel of process-indicative data is selected that can be used in place of multiple data channels without sacrificing consistent forewarning of critical events. Second, the method discards data of inadequate quality via statistical analysis of the raw data, because the analysis of poor quality data always yields inferior results. Third, two separate filtering operations are used in sequence to remove both high-frequency and low-frequency artifacts using a zero-phase quadratic filter. Fourth, the method constructs phase-space dissimilarity measures (PSDM) by combining of multi-channel time-serial data into a multi-channel time-delay phase-space reconstruction. Fifth, the method uses a composite measure of dissimilarity (C.sub.i) to provide a forewarning of failure and an indicator of failure onset.

  1. Terrestrial photovoltaic cell process testing

    NASA Technical Reports Server (NTRS)

    Burger, D. R.

    1985-01-01

    The paper examines critical test parameters, criteria for selecting appropriate tests, and the use of statistical controls and test patterns to enhance PV-cell process test results. The coverage of critical test parameters is evaluated by examining available test methods and then screening these methods by considering the ability to measure those critical parameters which are most affected by the generic process, the cost of the test equipment and test performance, and the feasibility for process testing.

  2. Terrestrial photovoltaic cell process testing

    NASA Astrophysics Data System (ADS)

    Burger, D. R.

    The paper examines critical test parameters, criteria for selecting appropriate tests, and the use of statistical controls and test patterns to enhance PV-cell process test results. The coverage of critical test parameters is evaluated by examining available test methods and then screening these methods by considering the ability to measure those critical parameters which are most affected by the generic process, the cost of the test equipment and test performance, and the feasibility for process testing.

  3. FOEHN: The critical experiment for the Franco-German High Flux Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scharmer, K.; Eckert, H. G.

    1991-01-01

    A critical experiment for the Franco-German High Flux Reactor was carried out in the French reactor EOLE (CEN Cadarache). The purpose of the experiment was to check the calculation methods in a realistic geometry and to measure effects that can only be calculated imprecisely (e.g. beam hole effects). The structure of the experiment and the measurement and calculation methods are described. A detailed comparison between theoretical and experimental results was performed. 30 refs., 105 figs.

  4. Measuring Person-Centered Care: A Critical Comparative Review of Published Tools

    ERIC Educational Resources Information Center

    Edvardsson, David; Innes, Anthea

    2010-01-01

    Purpose of the study: To present a critical comparative review of published tools measuring the person-centeredness of care for older people and people with dementia. Design and Methods: Included tools were identified by searches of PubMed, Cinahl, the Bradford Dementia Group database, and authors' files. The terms "Person-centered,"…

  5. Measuring cognition in teams: a cross-domain review.

    PubMed

    Wildman, Jessica L; Salas, Eduardo; Scott, Charles P R

    2014-08-01

    The purpose of this article is twofold: to provide a critical cross-domain evaluation of team cognition measurement options and to provide novice researchers with practical guidance when selecting a measurement method. A vast selection of measurement approaches exist for measuring team cognition constructs including team mental models, transactive memory systems, team situation awareness, strategic consensus, and cognitive processes. Empirical studies and theoretical articles were reviewed to identify all of the existing approaches for measuring team cognition. These approaches were evaluated based on theoretical perspective assumed, constructs studied, resources required, level of obtrusiveness, internal consistency reliability, and predictive validity. The evaluations suggest that all existing methods are viable options from the point of view of reliability and validity, and that there are potential opportunities for cross-domain use. For example, methods traditionally used only to measure mental models may be useful for examining transactive memory and situation awareness. The selection of team cognition measures requires researchers to answer several key questions regarding the theoretical nature of team cognition and the practical feasibility of each method. We provide novice researchers with guidance regarding how to begin the search for a team cognition measure and suggest several new ideas regarding future measurement research. We provide (1) a broad overview and evaluation of existing team cognition measurement methods, (2) suggestions for new uses of those methods across research domains, and (3) critical guidance for novice researchers looking to measure team cognition.

  6. Automated mask and wafer defect classification using a novel method for generalized CD variation measurements

    NASA Astrophysics Data System (ADS)

    Verechagin, V.; Kris, R.; Schwarzband, I.; Milstein, A.; Cohen, B.; Shkalim, A.; Levy, S.; Price, D.; Bal, E.

    2018-03-01

    Over the years, mask and wafers defects dispositioning has become an increasingly challenging and time consuming task. With design rules getting smaller, OPC getting complex and scanner illumination taking on free-form shapes - the probability of a user to perform accurate and repeatable classification of defects detected by mask inspection tools into pass/fail bins is reducing. The critical challenging of mask defect metrology for small nodes ( < 30 nm) was reviewed in [1]. While Critical Dimension (CD) variation measurement is still the method of choice for determining a mask defect future impact on wafer, the high complexity of OPCs combined with high variability in pattern shapes poses a challenge for any automated CD variation measurement method. In this study, a novel approach for measurement generalization is presented. CD variation assessment performance is evaluated on multiple different complex shape patterns, and is benchmarked against an existing qualified measurement methodology.

  7. Measuring reactive species and oxidative damage in vivo and in cell culture: how should you do it and what do the results mean?

    PubMed Central

    Halliwell, Barry; Whiteman, Matthew

    2004-01-01

    Free radicals and other reactive species (RS) are thought to play an important role in many human diseases. Establishing their precise role requires the ability to measure them and the oxidative damage that they cause. This article first reviews what is meant by the terms free radical, RS, antioxidant, oxidative damage and oxidative stress. It then critically examines methods used to trap RS, including spin trapping and aromatic hydroxylation, with a particular emphasis on those methods applicable to human studies. Methods used to measure oxidative damage to DNA, lipids and proteins and methods used to detect RS in cell culture, especially the various fluorescent ‘probes' of RS, are also critically reviewed. The emphasis throughout is on the caution that is needed in applying these methods in view of possible errors and artifacts in interpreting the results. PMID:15155533

  8. Models, measurement, and strategies in developing critical-thinking skills.

    PubMed

    Brunt, Barbara A

    2005-01-01

    Health care professionals must use critical-thinking skills to solve increasingly complex problems. Educators need to help nurses develop their critical-thinking skills to maintain and enhance their competence. This article reviews various models of critical thinking, as well as methods used to evaluate critical thinking. Specific educational strategies to develop nurses' critical-thinking skills are discussed. Additional research studies are needed to determine how the process of nursing practice can nurture and develop critical-thinking skills, and which strategies are most effective in developing and evaluating critical thinking.

  9. Student’s critical thinking skills in authentic problem based learning

    NASA Astrophysics Data System (ADS)

    Yuliati, L.; Fauziah, R.; Hidayat, A.

    2018-05-01

    This study aims to determine students’ critical thinking skills in authentic problem based learning, especially on geometric optics. The study was conducted at the vocational school. The study used a quantitative descriptive method with the open question to measure critical thinking skills. The indicators of critical thinking skills measured in this study are: formulating problems, providing simple answers, applying formulas and procedures, analyzing information, making conclusions, and synthesizing ideas. The results showed that there was a positive change in students’ critical thinking skills with the average value of N-Gain test is 0.59 and effect size test is 3.73. The critical thinking skills of students need to be trained more intensively using authentic problems in daily life.

  10. Analysis of Mathematics Critical Thinking Students in Junior High School Based on Cognitive Style

    NASA Astrophysics Data System (ADS)

    Agoestanto, A.; Sukestiyarno, YL; Rochmad

    2017-04-01

    The purpose of this research was to determine the critical thinking ability of mathematics from junior high school students based on FI and FD cognitive style. Data of this research were taken from students grade VIII at SMPN 2 Ambarawa. The research method used a descriptive qualitative approach. Data was taken with a testing method; the critical thinking was measured with WGCTA which is modified with mathematical problems, the cognitive style was measured with GEFT. The student’s test result was analysed, then four students were selected, the two of them are FI cognitive style, and the others are FD cognitive style, for qualitative analysis. The result showed that the ability of mathematics critical thinking students with FI cognitive style is better than FD cognitive style on the ability of inference, assumption, deduction, and interpretation. While on the aspect of argument evaluation, mathematics critical thinking ability of students with FD cognitive style is a little better than students with FI cognitive style.

  11. Sleep in the Intensive Care Unit

    PubMed Central

    Friese, Randall S.; Gehlbach, Brian K.; Schwab, Richard J.; Weinhouse, Gerald L.; Jones, Shirley F.

    2015-01-01

    Sleep is an important physiologic process, and lack of sleep is associated with a host of adverse outcomes. Basic and clinical research has documented the important role circadian rhythm plays in biologic function. Critical illness is a time of extreme vulnerability for patients, and the important role sleep may play in recovery for intensive care unit (ICU) patients is just beginning to be explored. This concise clinical review focuses on the current state of research examining sleep in critical illness. We discuss sleep and circadian rhythm abnormalities that occur in ICU patients and the challenges to measuring alterations in circadian rhythm in critical illness and review methods to measure sleep in the ICU, including polysomnography, actigraphy, and questionnaires. We discuss data on the impact of potentially modifiable disruptors to patient sleep, such as noise, light, and patient care activities, and report on potential methods to improve sleep in the setting of critical illness. Finally, we review the latest literature on sleep disturbances that persist or develop after critical illness. PMID:25594808

  12. Analyzing course objectives: assessing critical thinking in the pharmacy curriculum.

    PubMed

    Vuchetich, Phillip J; Hamilton, William R; Ahmad, S Omar; Makoid, Michael C

    2006-01-01

    Assessment of critical thinking objectives in a pharmacy program curriculum is an important part of program assessment. This study measures the proportion of cognitive learning objectives at various levels of Bloom's taxonomy throughout the required curriculum using the stated objectives in course syllabi (the explicit curriculum). In one entry level doctor of pharmacy program, 54.90% of cognitive objectives identified critical thinking outcomes using the rubric of Bloom's level 3 or higher as an indicator of critical thinking. In this program, there was a similar percent of critical thinking objectives in each of the first three years, but the final year of the curriculum had a higher percent of critical thinking objectives than each of the first three years (p = 0.0018, Kruskal-Wallis test). The increase in critical thinking in the final year suggests that the explicit expectations in the syllabi are weighted toward a higher percent of critical thinking objectives during clinical rotations. The methods described in the study may serve as tools for a curriculum committee or program assessment team to compare critical thinking in the curriculum at different points in time, and may assist in curricular mapping efforts. These methods may complement studies measuring the implicit curriculum (that which the faculty actually teach, which may not be stated in the explicit curriculum.).

  13. Flux-line response in 2H-NbSe 2 investigated by means of the vibrating superconductor method

    NASA Astrophysics Data System (ADS)

    D'Anna, G.; André, M.-O.; Benoit, W.; Rodríguez, E.; Rodríguez, D. S.; Luzuriaga, J.; Wasczak, J. V.

    1993-12-01

    We measure transverse AC losses in the low- and high-amplitude regime of 2H-NbSe 2 single crystals using vibrating superconductor methods. The measurements are sensitive to small deviations of the critical state. The data constitute evidence for a peak effect of the critical current as a function of the temperature in this compound. We construct in the H- T phase diagram the “peak-effect” line which is supposed to mark an abrupt cross-over in the vortex-pinning regime.

  14. Characterization of the Caliban and Prospero Critical Assemblies Neutron Spectra for Integral Measurements Experiments

    NASA Astrophysics Data System (ADS)

    Casoli, P.; Authier, N.; Jacquet, X.; Cartier, J.

    2014-04-01

    Caliban and Prospero are two highly enriched uranium metallic core reactors operated on the CEA Center of Valduc. These critical assemblies are suitable for integral experiments, such as fission yields measurements or perturbation measurements, which have been carried out recently on the Caliban reactor. Different unfolding methods, based on activation foils and fission chambers measurements, are used to characterize the reactor spectra and especially the Caliban spectrum, which is very close to a pure fission spectrum.

  15. Aluminum Data Measurements and Evaluation for Criticality Safety Applications

    NASA Astrophysics Data System (ADS)

    Leal, L. C.; Guber, K. H.; Spencer, R. R.; Derrien, H.; Wright, R. Q.

    2002-12-01

    The Defense Nuclear Facility Safety Board (DNFSB) Recommendation 93-2 motivated the US Department of Energy (DOE) to develop a comprehensive criticality safety program to maintain and to predict the criticality of systems throughout the DOE complex. To implement the response to the DNFSB Recommendation 93-2, a Nuclear Criticality Safety Program (NCSP) was created including the following tasks: Critical Experiments, Criticality Benchmarks, Training, Analytical Methods, and Nuclear Data. The Nuclear Data portion of the NCSP consists of a variety of differential measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) at the Oak Ridge National Laboratory (ORNL), data analysis and evaluation using the generalized least-squares fitting code SAMMY in the resolved, unresolved, and high energy ranges, and the development and benchmark testing of complete evaluations for a nuclide for inclusion into the Evaluated Nuclear Data File (ENDF/B). This paper outlines the work performed at ORNL to measure, evaluate, and test the nuclear data for aluminum for applications in criticality safety problems.

  16. Evaluation of pier-scour measurement methods and pier-scour predictions with observed scour measurements at selected bridge sites in New Hampshire, 1995-98

    DOT National Transportation Integrated Search

    2000-11-01

    In a previous study, 44 of 48 bridge sites examined in New Hampshire were categorized as scour critical. This report summarizes research conducted to evaluate pier-scour measurement methods and predictions at many of these sites. This evaluation incl...

  17. Neural network and multiple linear regression to predict school children dimensions for ergonomic school furniture design.

    PubMed

    Agha, Salah R; Alnahhal, Mohammed J

    2012-11-01

    The current study investigates the possibility of obtaining the anthropometric dimensions, critical to school furniture design, without measuring all of them. The study first selects some anthropometric dimensions that are easy to measure. Two methods are then used to check if these easy-to-measure dimensions can predict the dimensions critical to the furniture design. These methods are multiple linear regression and neural networks. Each dimension that is deemed necessary to ergonomically design school furniture is expressed as a function of some other measured anthropometric dimensions. Results show that out of the five dimensions needed for chair design, four can be related to other dimensions that can be measured while children are standing. Therefore, the method suggested here would definitely save time and effort and avoid the difficulty of dealing with students while measuring these dimensions. In general, it was found that neural networks perform better than multiple linear regression in the current study. Copyright © 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  18. Instrumented Measurement of Balance and Postural Control in Individuals with Lower Limb Amputation: A Critical Review

    ERIC Educational Resources Information Center

    Jayakaran, Prasath; Johnson, Gillian M.; Sullivan, S. John; Nitz, Jennifer C.

    2012-01-01

    Measurement of balance and postural performance that underpins activities of daily living is important in the rehabilitation of individuals with a lower limb amputation (LLA), and there are a number of methods and strategies available for this purpose. To provide an evidence-based choice of approach, this review aims to critically review the tasks…

  19. A Cyber Security Self-Assessment Method for Nuclear Power Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glantz, Clifford S.; Coles, Garill A.; Bass, Robert B.

    2004-11-01

    A cyber security self-assessment method (the Method) has been developed by Pacific Northwest National Laboratory. The development of the Method was sponsored and directed by the U.S. Nuclear Regulatory Commission. Members of the Nuclear Energy Institute Cyber Security Task Force also played a substantial role in developing the Method. The Method's structured approach guides nuclear power plants in scrutinizing their digital systems, assessing the potential consequences to the plant of a cyber exploitation, identifying vulnerabilities, estimating cyber security risks, and adopting cost-effective protective measures. The focus of the Method is on critical digital assets. A critical digital asset is amore » digital device or system that plays a role in the operation, maintenance, or proper functioning of a critical system (i.e., a plant system that can impact safety, security, or emergency preparedness). A critical digital asset may have a direct or indirect connection to a critical system. Direct connections include both wired and wireless communication pathways. Indirect connections include sneaker-net pathways by which software or data are manually transferred from one digital device to another. An indirect connection also may involve the use of instructions or data stored on a critical digital asset to make adjustments to a critical system. The cyber security self-assessment begins with the formation of an assessment team, and is followed by a six-stage process.« less

  20. 12 CFR Appendix B to Part 741 - Guidance for an Interest Rate Risk Policy and an Effective Program

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Measurement Methods C. Components of IRR Measurement Methods V. Internal Controls VI. Decision-Making Informed... effective IRR management program identifies, measures, monitors, and controls IRR and is central to safe and... critical to the control of IRR exposure. All FICUs required to have an IRR policy and program should...

  1. 12 CFR Appendix B to Part 741 - Guidance for an Interest Rate Risk Policy and an Effective Program

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Measurement Methods C. Components of IRR Measurement Methods V. Internal Controls VI. Decision-Making Informed... effective IRR management program identifies, measures, monitors, and controls IRR and is central to safe and... critical to the control of IRR exposure. All FICUs required to have an IRR policy and program should...

  2. Development of congestion performance measures using ITS information.

    DOT National Transportation Integrated Search

    2003-01-01

    The objectives of this study were to define a performance measure(s) that could be used to show congestion levels on critical corridors throughout Virginia and to develop a method to select and calculate performance measures to quantify congestion in...

  3. PVT properties and vapor-pressures of ordinary water substance in the critical region

    NASA Astrophysics Data System (ADS)

    Morita, T.; Sato, H.; Uematsu, M.; Watanabe, K.

    1989-03-01

    For the purpose of revealing the rather complicated thermodynamic surface of ordinary water substance in the critical region, a series of measurements of the PVT properties and the vapor-pressures of this technically important fluid have been performed by means of a constant-volume method. Ninety-three PVT measurements along 14 isotherms between 638.15 K and 652.15 K have been completed covering pressures from 18.5 to 39.2 MPa and densities from 122 to 610kg/m 3. Twenty-six vapor-pressure measurements have also been performed at temperatures between 620.15 K and 647.05 K in the near vicinity of the critical point. Our measurements are compared with other available experimental data as well as with several equations of state. We also propose a new vapor-pressure correlation from the triple point to the critical point.

  4. Cell-free measurements of brightness of fluorescently labeled antibodies

    PubMed Central

    Zhou, Haiying; Tourkakis, George; Shi, Dennis; Kim, David M.; Zhang, Hairong; Du, Tommy; Eades, William C.; Berezin, Mikhail Y.

    2017-01-01

    Validation of imaging contrast agents, such as fluorescently labeled imaging antibodies, has been recognized as a critical challenge in clinical and preclinical studies. As the number of applications for imaging antibodies grows, these materials are increasingly being subjected to careful scrutiny. Antibody fluorescent brightness is one of the key parameters that is of critical importance. Direct measurements of the brightness with common spectroscopy methods are challenging, because the fluorescent properties of the imaging antibodies are highly sensitive to the methods of conjugation, degree of labeling, and contamination with free dyes. Traditional methods rely on cell-based assays that lack reproducibility and accuracy. In this manuscript, we present a novel and general approach for measuring the brightness using antibody-avid polystyrene beads and flow cytometry. As compared to a cell-based method, the described technique is rapid, quantitative, and highly reproducible. The proposed method requires less than ten microgram of sample and is applicable for optimizing synthetic conjugation procedures, testing commercial imaging antibodies, and performing high-throughput validation of conjugation procedures. PMID:28150730

  5. Method And Apparatus For Evaluatin Of High Temperature Superconductors

    DOEpatents

    Fishman, Ilya M.; Kino, Gordon S.

    1996-11-12

    A technique for evaluation of high-T.sub.c superconducting films and single crystals is based on measurement of temperature dependence of differential optical reflectivity of high-T.sub.c materials. In the claimed method, specific parameters of the superconducting transition such as the critical temperature, anisotropy of the differential optical reflectivity response, and the part of the optical losses related to sample quality are measured. The apparatus for performing this technique includes pump and probe sources, cooling means for sweeping sample temperature across the critical temperature and polarization controller for controlling a state of polarization of a probe light beam.

  6. Comparison of two methods of measuring gastric pH.

    PubMed

    Neill, K M; Rice, K T; Ahern, H L

    1993-01-01

    To assess the agreement between two methods of measuring gastric pH in critically ill patients (multiple band litmus paper-tested aspirations versus a meter-read probe located in the tip of a nasogastric tube) and to compare nurse satisfaction with both methods of measuring pH. Prospective, correlational, nonprobability sample. Mid-Atlantic, semirural Veterans Affairs Medical Center. 39 male, surgical, critical care patients, who were nasogastrically intubated in the operating room and received nothing by mouth. NURSES: Twenty-seven registered nurses on the medical-surgical intensive care staff. Differences in pH units as determined by two methods of measurement and nurse satisfaction scores. Litmus paper-tested aspirations versus a meter-read probe located in the tip of the nasogastric tube, measured every 2 hours for 48 hours. A nurse satisfaction assessment form for both measurement methods at entry, 6 months, and 12 months. All measures of association, Pearson's r (0.79), the concordance coefficient (0.74), and eta (0.88), were high. The concordance coefficient measures indicated sufficient agreement between the two methods at the initial and 24 hour measurement times (Cb) = 0.97, 0.97, and 0.94), but not at 48 hours. The meter method indicated prophylaxis was needed when the paper did not, more often than did the paper method (9.3% vs 5.2%). A significant difference between methods was found only at the last reading at 48 hours (z = -2.24, p < .0249). MANOVA revealed that nurses' preference for the meter method was significant (F = 139.48, df = 1.18) and increased over time (F = 4.77, df = 2,36). The gastric probe method of measuring pH is an accurate substitution up to 48 hours for the litmus-paper aspiration method in the postoperative patient who is receiving nothing by mouth. Nurses prefer the gastric probe method of measuring pH over the litmus-paper method because they judge it to be safer, faster, and more accurate.

  7. Measuring Spray Droplet Size from Agricultural Nozzles Using Laser Diffraction

    PubMed Central

    Fritz, Bradley K.; Hoffmann, W. Clint

    2016-01-01

    When making an application of any crop protection material such as an herbicide or pesticide, the applicator uses a variety of skills and information to make an application so that the material reaches the target site (i.e., plant). Information critical in this process is the droplet size that a particular spray nozzle, spray pressure, and spray solution combination generates, as droplet size greatly influences product efficacy and how the spray moves through the environment. Researchers and product manufacturers commonly use laser diffraction equipment to measure the spray droplet size in laboratory wind tunnels. The work presented here describes methods used in making spray droplet size measurements with laser diffraction equipment for both ground and aerial application scenarios that can be used to ensure inter- and intra-laboratory precision while minimizing sampling bias associated with laser diffraction systems. Maintaining critical measurement distances and concurrent airflow throughout the testing process is key to this precision. Real time data quality analysis is also critical to preventing excess variation in the data or extraneous inclusion of erroneous data. Some limitations of this method include atypical spray nozzles, spray solutions or application conditions that result in spray streams that do not fully atomize within the measurement distances discussed. Successful adaption of this method can provide a highly efficient method for evaluation of the performance of agrochemical spray application nozzles under a variety of operational settings. Also discussed are potential experimental design considerations that can be included to enhance functionality of the data collected. PMID:27684589

  8. A biomechanical model for fibril recruitment: Evaluation in tendons and arteries.

    PubMed

    Bevan, Tim; Merabet, Nadege; Hornsby, Jack; Watton, Paul N; Thompson, Mark S

    2018-06-06

    Simulations of soft tissue mechanobiological behaviour are increasingly important for clinical prediction of aneurysm, tendinopathy and other disorders. Mechanical behaviour at low stretches is governed by fibril straightening, transitioning into load-bearing at recruitment stretch, resulting in a tissue stiffening effect. Previous investigations have suggested theoretical relationships between stress-stretch measurements and recruitment probability density function (PDF) but not derived these rigorously nor evaluated these experimentally. Other work has proposed image-based methods for measurement of recruitment but made use of arbitrary fibril critical straightness parameters. The aim of this work was to provide a sound theoretical basis for estimating recruitment PDF from stress-stretch measurements and to evaluate this relationship using image-based methods, clearly motivating the choice of fibril critical straightness parameter in rat tail tendon and porcine artery. Rigorous derivation showed that the recruitment PDF may be estimated from the second stretch derivative of the first Piola-Kirchoff tissue stress. Image-based fibril recruitment identified the fibril straightness parameter that maximised Pearson correlation coefficients (PCC) with estimated PDFs. Using these critical straightness parameters the new method for estimating recruitment PDF showed a PCC with image-based measures of 0.915 and 0.933 for tendons and arteries respectively. This method may be used for accurate estimation of fibril recruitment PDF in mechanobiological simulation where fibril-level mechanical parameters are important for predicting cell behaviour. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Method for accurate growth of vertical-cavity surface-emitting lasers

    DOEpatents

    Chalmers, Scott A.; Killeen, Kevin P.; Lear, Kevin L.

    1995-01-01

    We report a method for accurate growth of vertical-cavity surface-emitting lasers (VCSELs). The method uses a single reflectivity spectrum measurement to determine the structure of the partially completed VCSEL at a critical point of growth. This information, along with the extracted growth rates, allows imprecisions in growth parameters to be compensated for during growth of the remaining structure, which can then be completed with very accurate critical dimensions. Using this method, we can now routinely grow lasing VCSELs with Fabry-Perot cavity resonance wavelengths controlled to within 0.5%.

  10. Delineating floodplain and upload areas for hydrologic models: A comparison of methods

    USDA-ARS?s Scientific Manuscript database

    A spatially distributed representation of basin hydrology and transport processes in eco-hydrological models facilitates the identification of critical source areas and the placement of management and conservation measures. Floodplains are critical landscape features that differ from neighboring up...

  11. Characterization of the CALIBAN Critical Assembly Neutron Spectra using Several Adjustment Methods Based on Activation Foils Measurement

    NASA Astrophysics Data System (ADS)

    Casoli, Pierre; Grégoire, Gilles; Rousseau, Guillaume; Jacquet, Xavier; Authier, Nicolas

    2016-02-01

    CALIBAN is a metallic critical assembly managed by the Criticality, Neutron Science and Measurement Department located on the French CEA Center of Valduc. The reactor is extensively used for benchmark experiments dedicated to the evaluation of nuclear data, for electronic hardening or to study the effect of the neutrons on various materials. Therefore CALIBAN irradiation characteristics and especially its central cavity neutron spectrum have to be very accurately evaluated. In order to strengthen our knowledge of this spectrum, several adjustment methods based on activation foils measurements are being studied for a few years in the laboratory. Firstly two codes included in the UMG package have been tested and compared: MAXED and GRAVEL. More recently, the CALIBAN cavity spectrum has been studied using CALMAR, a new adjustment tool currently under development at the CEA Center of Cadarache. The article will discuss and compare the results and the quality of spectrum rebuilding obtained with the UMG codes and with the CALMAR software, from a set of activation measurements carried out in the CALIBAN irradiation cavity.

  12. In-die photomask registration and overlay metrology with PROVE using 2D correlation methods

    NASA Astrophysics Data System (ADS)

    Seidel, D.; Arnz, M.; Beyer, D.

    2011-11-01

    According to the ITRS roadmap, semiconductor industry drives the 193nm lithography to its limits, using techniques like double exposure, double patterning, mask-source optimization and inverse lithography. For photomask metrology this translates to full in-die measurement capability for registration and critical dimension together with challenging specifications for repeatability and accuracy. Especially, overlay becomes more and more critical and must be ensured on every die. For this, Carl Zeiss SMS has developed the next generation photomask registration and overlay metrology tool PROVE® which serves the 32nm node and below and which is already well established in the market. PROVE® features highly stable hardware components for the stage and environmental control. To ensure in-die measurement capability, sophisticated image analysis methods based on 2D correlations have been developed. In this paper we demonstrate the in-die capability of PROVE® and present corresponding measurement results for shortterm and long-term measurements as well as the attainable accuracy for feature sizes down to 85nm using different illumination modes and mask types. Standard measurement methods based on threshold criteria are compared with the new 2D correlation methods to demonstrate the performance gain of the latter. In addition, mask-to-mask overlay results of typical box-in-frame structures down to 200nm feature size are presented. It is shown, that from overlay measurements a reproducibility budget can be derived that takes into account stage, image analysis and global effects like mask loading and environmental control. The parts of the budget are quantified from measurement results to identify critical error contributions and to focus on the corresponding improvement strategies.

  13. Metrology in Medicine: From Measurements to Decision, with Specific Reference to Anesthesia and Intensive Care

    PubMed Central

    Imhoff, Michael; Cecconi, Maurizio

    2015-01-01

    Metrology is the science of measurements. Although of critical importance in medicine and especially in critical care, frequent confusion in terms and definitions impact either interphysician communications or understanding of manufacturers’ and engineers’ instructions and limitations when using devices. In this review, we first list the terms defined by the International Bureau of Weights and Measures regarding quantities and units, measurements, devices for measurement, properties of measuring devices, and measurement standards. The traditional tools for assessing the most important measurement quality criteria are also reviewed with clinical examples for diagnosis, alarm, and titration purposes, as well as for assessing the uncertainty of reference methods. PMID:25625255

  14. Critical Thinking and the Use of Nontraditional Instructional Methodologies.

    PubMed

    Orique, Sabrina B; McCarthy, Mary Ann

    2015-08-01

    The purpose of this study was to examine the relationship between critical thinking and the use of concept mapping (CM) and problem-based learning (PBL) during care plan development. A quasi-experimental study with a pretest-posttest design was conducted using a convenience sample (n = 49) of first-semester undergraduate baccalaureate nursing students. Critical thinking was measured using the Holistic Critical Thinking Scoring Rubric. Data analysis consisted of a repeated measures analysis of variance with post hoc mean comparison tests using the Bonferroni method. Findings indicated that mean critical thinking at phase 4 (CM and PBL) was significantly higher, compared with phase 1 (baseline), phase 2 (PBL), and phase 3 (CM [p < 0.001]). The results support the utilization of nontraditional instructional (CM and PBL) methodologies in undergraduate nursing curricula. Copyright 2015, SLACK Incorporated.

  15. 'Known Secure Sensor Measurements' for Critical Infrastructure Systems: Detecting Falsification of System State

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miles McQueen; Annarita Giani

    2011-09-01

    This paper describes a first investigation on a low cost and low false alarm, reliable mechanism for detecting manipulation of critical physical processes and falsification of system state. We call this novel mechanism Known Secure Sensor Measurements (KSSM). The method moves beyond analysis of network traffic and host based state information, in fact it uses physical measurements of the process being controlled to detect falsification of state. KSSM is intended to be incorporated into the design of new, resilient, cost effective critical infrastructure control systems. It can also be included in incremental upgrades of already in- stalled systems for enhancedmore » resilience. KSSM is based on known secure physical measurements for assessing the likelihood of an attack and will demonstrate a practical approach to creating, transmitting, and using the known secure measurements for detection.« less

  16. Residual Stress Measurement and Calibration for A7N01 Aluminum Alloy Welded Joints by Using Longitudinal Critically Refracted ( LCR) Wave Transmission Method

    NASA Astrophysics Data System (ADS)

    Zhu, Qimeng; Chen, Jia; Gou, Guoqing; Chen, Hui; Li, Peng; Gao, W.

    2016-10-01

    Residual stress measurement and control are highly important for the safety of structures of high-speed trains, which is critical for the structure design. The longitudinal critically refracted wave technology is the most widely used method in measuring residual stress with ultrasonic method, but its accuracy is strongly related to the test parameters, namely the flight time at the free-stress condition ( t 0), stress coefficient ( K), and initial stress (σ0) of the measured materials. The difference of microstructure in the weld zone, heat affected zone, and base metal (BM) results in the divergence of experimental parameters. However, the majority of researchers use the BM parameters to determine the residual stress in other zones and ignore the initial stress (σ0) in calibration samples. Therefore, the measured residual stress in different zones is often high in errors and may result in the miscalculation of the safe design of important structures. A serious problem in the ultrasonic estimation of residual stresses requires separation between the microstructure and the acoustoelastic effects. In this paper, the effects of initial stress and microstructure on stress coefficient K and flight time t 0 at free-stress conditions have been studied. The residual stress with or without different corrections was investigated. The results indicated that the residual stresses obtained with correction are more accurate for structure design.

  17. Burst wait time simulation of CALIBAN reactor at delayed super-critical state

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Humbert, P.; Authier, N.; Richard, B.

    2012-07-01

    In the past, the super prompt critical wait time probability distribution was measured on CALIBAN fast burst reactor [4]. Afterwards, these experiments were simulated with a very good agreement by solving the non-extinction probability equation [5]. Recently, the burst wait time probability distribution has been measured at CEA-Valduc on CALIBAN at different delayed super-critical states [6]. However, in the delayed super-critical case the non-extinction probability does not give access to the wait time distribution. In this case it is necessary to compute the time dependent evolution of the full neutron count number probability distribution. In this paper we present themore » point model deterministic method used to calculate the probability distribution of the wait time before a prescribed count level taking into account prompt neutrons and delayed neutron precursors. This method is based on the solution of the time dependent adjoint Kolmogorov master equations for the number of detections using the generating function methodology [8,9,10] and inverse discrete Fourier transforms. The obtained results are then compared to the measurements and Monte-Carlo calculations based on the algorithm presented in [7]. (authors)« less

  18. Quality assurance, training, and certification in ozone air pollution studies

    Treesearch

    Susan Schilling; Paul Miller; Brent Takemoto

    1996-01-01

    Uniform, or standard, measurement methods of data are critical to projects monitoring change to forest systems. Standardized methods, with known or estimable errors, contribute greatly to the confidence associated with decisions on the basis of field data collections (Zedaker and Nicholas 1990). Quality assurance (QA) for the measurement process includes operations and...

  19. Progress on core outcome sets for critical care research.

    PubMed

    Blackwood, Bronagh; Marshall, John; Rose, Louise

    2015-10-01

    Appropriate selection and definition of outcome measures are essential for clinical trials to be maximally informative. Core outcome sets (an agreed, standardized collection of outcomes measured and reported in all trials for a specific clinical area) were developed due to established inconsistencies in trial outcome selection. This review discusses the rationale for, and methods of, core outcome set development, as well as current initiatives in critical care. Recent systematic reviews of reported outcomes and measurement instruments relevant to the critically ill highlight inconsistencies in outcome selection, definition, and measurement, thus establishing the need for core outcome sets. Current critical care initiatives include development of core outcome sets for trials aimed at reducing mechanical ventilation duration; rehabilitation following critical illness; long-term outcomes in acute respiratory failure; and epidemic and pandemic studies of severe acute respiratory infection. Development and utilization of core outcome sets for studies relevant to the critically ill is in its infancy compared to other specialties. Notwithstanding, core outcome set development frameworks and guidelines are available, several sets are in various stages of development, and there is strong support from international investigator-led collaborations including the International Forum for Acute Care Trialists.

  20. A simple method to measure critical angles for high-sensitivity differential refractometry.

    PubMed

    Zilio, S C

    2012-01-16

    A total internal reflection-based differencial refractometer, capable of measuring the real and imaginary parts of the complex refractive index in real time, is presented. The device takes advantage of the phase difference acquired by s- and p-polarized light to generate an easily detectable minimum at the reflected profile. The method allows to sensitively measuring transparent and turbid liquid samples.

  1. Critically Reflective Work Behavior of Health Care Professionals

    ERIC Educational Resources Information Center

    de Groot, Esther; Jaarsma, Debbie; Endedijk, Maaike; Mainhard, Tim; Lam, Ineke; Simons, Robert-Jan; van Beukelen, Peter

    2012-01-01

    Introduction: Better understanding of critically reflective work behavior (CRWB), an approach for work-related informal learning, is important in order to gain more profound insight in the continuing development of health care professionals. Methods: A survey, developed to measure CRWB and its predictors, was distributed to veterinary…

  2. Diagnostics of transparent polymer coatings of metal items

    NASA Astrophysics Data System (ADS)

    Varepo, L. G.; Ermakova, I. N.; Nagornova, I. V.; Kondratov, A. P.

    2017-08-01

    The methods of visual and instrumental express diagnostics of safety critical defects and non-uniform thickness of transparent mono- and multilayer polyolefin surface coating of metal items are analyzed in the paper. The instrumental diagnostics method relates to colorimetric measuring based on effects, which appear in the polarized light for extrusion polymer coatings. A color coordinates dependence (in the color system CIE La*b*) on both HDPE / PVC coating thickness fluctuation values (from average ones) and coating interlayer or adhesion layer delaminating is shown. A variation of color characteristics in the polarized light at a liquid penetration into delaminated polymer layers is found. Measuring parameters and critical uncertainties are defined.

  3. Method for accurate growth of vertical-cavity surface-emitting lasers

    DOEpatents

    Chalmers, S.A.; Killeen, K.P.; Lear, K.L.

    1995-03-14

    The authors report a method for accurate growth of vertical-cavity surface-emitting lasers (VCSELs). The method uses a single reflectivity spectrum measurement to determine the structure of the partially completed VCSEL at a critical point of growth. This information, along with the extracted growth rates, allows imprecisions in growth parameters to be compensated for during growth of the remaining structure, which can then be completed with very accurate critical dimensions. Using this method, they can now routinely grow lasing VCSELs with Fabry-Perot cavity resonance wavelengths controlled to within 0.5%. 4 figs.

  4. Disrupting the Pipeline: Critical Analyses of Student Pathways through Postsecondary STEM Education

    ERIC Educational Resources Information Center

    Metcalf, Heather E.

    2014-01-01

    Critical mixed methods approaches allow us to reflect upon the ways in which we collect, measure, interpret, and analyze data, providing novel alternatives for quantitative analysis. For institutional researchers, whose work influences institutional policies, programs, and practices, the approach has the transformative ability to expose and create…

  5. Assessment of Teaching Methods and Critical Thinking in a Course for Science Majors

    NASA Astrophysics Data System (ADS)

    Speck, Angela; Ruzhitskaya, L.; Whittington, A. G.

    2014-01-01

    Ability to think critically is a key ingredient to the scientific mindset. Students who take science courses may or may not be predisposed to critical thinking - the ability to evaluate information analytically. Regardless of their initial stages, students can significantly improve their critical thinking through learning and practicing their reasoning skills, critical assessments, conducting and reflecting on observations and experiments, building their questioning and communication skills, and through the use of other techniques. While, there are several of teaching methods that may help to improve critical thinking, there are only a few assessment instruments that can help in evaluating the efficacy of these methods. Critical thinking skills and improvement in those skills are notoriously difficult to measure. Assessments that are based on multiple-choice questions demonstrate students’ final decisions but not their thinking processes. In addition, during the course of studies students may develop subject-based critical thinking while not being able to extend the skills to the general critical thinking. As such, we wanted to design and conduct a study on efficacy of several teaching methods in which we would learn how students’ improve their thinking processes within a science discipline as well as in everyday life situations. We conducted a study among 20 astronomy, physics and geology majors-- both graduate and undergraduate students-- enrolled in our Solar System Science course (mostly seniors and early graduate students) at the University of Missouri. We used the Ennis-Weir Critical Thinking Essay test to assess students’ general critical thinking and, in addition, we implemented our own subject-based critical thinking assessment. Here, we present the results of this study and share our experience on designing a subject-based critical thinking assessment instrument.

  6. Technological Literacy for Students Aged 6-18: A New Method for Holistic Measuring of Knowledge, Capabilities, Critical Thinking and Decision-Making

    ERIC Educational Resources Information Center

    Avsec, Stanislav; Jamšek, Janez

    2016-01-01

    Technological literacy is identified as a vital achievement of technology- and engineering-intensive education. It guides the design of technology and technical components of educational systems and defines competitive employment in technological society. Existing methods for measuring technological literacy are incomplete or complicated,…

  7. Biomass Burning Aerosol Absorption Measurements with MODIS Using the Critical Reflectance Method

    NASA Technical Reports Server (NTRS)

    Zhu, Li; Martins, Vanderlei J.; Remer, Lorraine A.

    2010-01-01

    This research uses the critical reflectance technique, a space-based remote sensing method, to measure the spatial distribution of aerosol absorption properties over land. Choosing two regions dominated by biomass burning aerosols, a series of sensitivity studies were undertaken to analyze the potential limitations of this method for the type of aerosol to be encountered in the selected study areas, and to show that the retrieved results are relatively insensitive to uncertainties in the assumptions used in the retrieval of smoke aerosol. The critical reflectance technique is then applied to Moderate Resolution Imaging Spectrometer (MODIS) data to retrieve the spectral aerosol single scattering albedo (SSA) in South African and South American 35 biomass burning events. The retrieved results were validated with collocated Aerosol Robotic Network (AERONET) retrievals. One standard deviation of mean MODIS retrievals match AERONET products to within 0.03, the magnitude of the AERONET uncertainty. The overlap of the two retrievals increases to 88%, allowing for measurement variance in the MODIS retrievals as well. The ensemble average of MODIS-derived SSA for the Amazon forest station is 0.92 at 670 nm, and 0.84-0.89 for the southern African savanna stations. The critical reflectance technique allows evaluation of the spatial variability of SSA, and shows that SSA in South America exhibits higher spatial variation than in South Africa. The accuracy of the retrieved aerosol SSA from MODIS data indicates that this product can help to better understand 44 how aerosols affect the regional and global climate.

  8. Cyber-Critical Infrastructure Protection Using Real-Time Payload-Based Anomaly Detection

    NASA Astrophysics Data System (ADS)

    Düssel, Patrick; Gehl, Christian; Laskov, Pavel; Bußer, Jens-Uwe; Störmann, Christof; Kästner, Jan

    With an increasing demand of inter-connectivity and protocol standardization modern cyber-critical infrastructures are exposed to a multitude of serious threats that may give rise to severe damage for life and assets without the implementation of proper safeguards. Thus, we propose a method that is capable to reliably detect unknown, exploit-based attacks on cyber-critical infrastructures carried out over the network. We illustrate the effectiveness of the proposed method by conducting experiments on network traffic that can be found in modern industrial control systems. Moreover, we provide results of a throughput measuring which demonstrate the real-time capabilities of our system.

  9. Reaction kinetics and critical phenomena: iodination of acetone in isobutyric acid + water near the consolute point.

    PubMed

    Hu, Baichuan; Baird, James K

    2010-01-14

    The rate of iodination of acetone has been measured as a function of temperature in the binary solvent isobutyric acid (IBA) + water near the upper consolute point. The reaction mixture was prepared by the addition of acetone, iodine, and potassium iodide to IBA + water at its critical composition of 38.8 mass % IBA. The value of the critical temperature determined immediately after mixing was 25.43 degrees C. Aliquots were extracted from the mixture at regular intervals in order to follow the time course of the reaction. After dilution of the aliquot with water to quench the reaction, the concentration of triiodide ion was determined by the measurement of the optical density at a wavelength of 565 nm. These measurements showed that the kinetics were zeroth order. When at the end of 24 h the reaction had come to equilibrium, the critical temperature was determined again and found to be 24.83 degrees C. An Arrhenius plot of the temperature dependence of the observed rate constant, k(obs), was linear over the temperature range 27.00-38.00 degrees C, but between 25.43 and 27.00 degrees C, the values of k(obs) fell below the extrapolation of the Arrhenius line. This behavior is evidence in support of critical slowing down. Our experimental method and results are significant in three ways: (1) In contrast to in situ measurements of optical density, the determination of the optical density of diluted aliquots avoided any interference from critical opalescence. (2) The measured reaction rate exhibited critical slowing down. (3) The rate law was pseudo zeroth order both inside and outside the critical region, indicating that the reaction mechanism was unaffected by the presence of the critical point.

  10. Critical thinking versus clinical reasoning versus clinical judgment: differential diagnosis.

    PubMed

    Victor-Chmil, Joyce

    2013-01-01

    Concepts of critical thinking, clinical reasoning, and clinical judgment are often used interchangeably. However, they are not one and the same, and understanding subtle difference among them is important. Following a review of the literature for definitions and uses of the terms, the author provides a summary focused on similarities and differences in the processes of critical thinking, clinical reasoning, and clinical judgment and notes suggested methods of measuring each.

  11. Experimental methods to validate measures of emotional state and readiness for duty in critical operations.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weston, Louise Marie

    2007-09-01

    A recent report on criticality accidents in nuclear facilities indicates that human error played a major role in a significant number of incidents with serious consequences and that some of these human errors may be related to the emotional state of the individual. A pre-shift test to detect a deleterious emotional state could reduce the occurrence of such errors in critical operations. The effectiveness of pre-shift testing is a challenge because of the need to gather predictive data in a relatively short test period and the potential occurrence of learning effects due to a requirement for frequent testing. This reportmore » reviews the different types of reliability and validity methods and testing and statistical analysis procedures to validate measures of emotional state. The ultimate value of a validation study depends upon the percentage of human errors in critical operations that are due to the emotional state of the individual. A review of the literature to identify the most promising predictors of emotional state for this application is highly recommended.« less

  12. Comparing the Effects of Simulation-Based and Traditional Teaching Methods on the Critical Thinking Abilities and Self-Confidence of Nursing Students.

    PubMed

    Alamrani, Mashael Hasan; Alammar, Kamila Ahmad; Alqahtani, Sarah Saad; Salem, Olfat A

    2018-06-01

    Critical thinking and self-confidence are imperative to success in clinical practice. Educators should use teaching strategies that will help students enhance their critical thinking and self-confidence in complex content such as electrocardiogram interpretation. Therefore, teaching electrocardiogram interpretation to students is important for nurse educators. This study compares the effect of simulation-based and traditional teaching methods on the critical thinking and self-confidence of students during electrocardiogram interpretation sessions. Thirty undergraduate nursing students volunteered to participate in this study. The participants were divided into intervention and control groups, which were taught respectively using the simulation-based and traditional teaching programs. All of the participants were asked to complete the study instrumentpretest and posttest to measure their critical thinking and self-confidence. Improvement was observed in the control and experimental groups with respect to critical thinking and self-confidence, as evidenced by the results of the paired samples t test and the Wilcoxon signed-rank test (p < .05). However, the independent t test and Mann-Whitney U test indicate that the difference between the two groups was not significant (p > .05). This study evaluated an innovative simulation-based teaching method for nurses. No significant differences in outcomes were identified between the simulator-based and traditional teaching methods, indicating that well-implemented educational programs that use either teaching method effectively promote critical thinking and self-confidence in nursing students. Nurse educators are encouraged to design educational plans with clear objectives to improve the critical thinking and self-confidence of their students. Future research should compare the effects of several teaching sessions using each method in a larger sample.

  13. The spaced antenna drift method

    NASA Technical Reports Server (NTRS)

    Hocking, W. K.

    1983-01-01

    The spaced antenna drift method is a simple and relatively inexpensive method for determination of atmospheric wind velocities using radars. The technique has been extensively tested in the mesosphere at high and medium frequencies, and found to give reliable results. Recently, the method has also been applied to VHF observations of the troposphere and stratosphere, and results appear to be reliable. This paper discusses briefly the principle of the method, and investigates both its strengths and weaknesses. Some discussions concerning criticisms of the technique are also given, and it is concluded that while these criticisms may be of some concern at times, appropriate care can ensure that the method is at least as viable as any other method of remote wind measurement. At times, the technique has definite advantages.

  14. Experimental and Numerical Study on the Cracked Chevron Notched Semi-Circular Bend Method for Characterizing the Mode I Fracture Toughness of Rocks

    NASA Astrophysics Data System (ADS)

    Wei, Ming-Dong; Dai, Feng; Xu, Nu-Wen; Liu, Jian-Feng; Xu, Yuan

    2016-05-01

    The cracked chevron notched semi-circular bending (CCNSCB) method for measuring the mode I fracture toughness of rocks combines the merits (e.g., avoidance of tedious pre-cracking of notch tips, ease of sample preparation and loading accommodation) of both methods suggested by the International Society for Rock Mechanics, which are the cracked chevron notched Brazilian disc (CCNBD) method and the notched semi-circular bend (NSCB) method. However, the limited availability of the critical dimensionless stress intensity factor (SIF) values severely hinders the widespread usage of the CCNSCB method. In this study, the critical SIFs are determined for a wide range of CCNSCB specimen geometries via three-dimensional finite element analysis. A relatively large support span in the three point bending configuration was considered because the fracture of the CCNSCB specimen in that situation is finely restricted in the notch ligament, which has been commonly assumed for mode I fracture toughness measurements using chevron notched rock specimens. Both CCNSCB and NSCB tests were conducted to measure the fracture toughness of two different rock types; for each rock type, the two methods produce similar toughness values. Given the reported experimental results, the CCNSCB method can be reliable for characterizing the mode I fracture toughness of rocks.

  15. METHODS STUDIES FOR THE NATIONAL CHILDREN'S STUDY: SEMIPERMEABLE MEMBRANE DEVICE (SPMD)

    EPA Science Inventory

    Accurate exposure classification tools are required to link exposure with health effects in epidemiological studies. Although long-term integrated exposure measurements are a critical component of exposure assessment, the ability to include these measurements into epidemiologic...

  16. METHODS STUDIES FOR THE NATIONAL CHILDREN'S STUDY: MOLECULARLY IMPRINTED POLYMERS

    EPA Science Inventory

    Accurate exposure classification tools are required to link exposure with health effects in epidemiological studies. Although long-term integrated exposure measurements are a critical component of exposure assessment, the ability to include these measurements into epidemiologic...

  17. Profile of Students’ Critical Thinking Skill Measured by Science Virtual Test on Living Things and Environmental Sustainability Theme

    NASA Astrophysics Data System (ADS)

    Maulida, N. I.; Firman, H.; Rusyati, L.

    2017-02-01

    The aims of this study are: (1) to investigate the level of students’ critical thinking skill on living things and environmental sustainability theme for each Inch’ critical thinking elements and overall, (2) to investigate the level of students’ critical thinking skill on living things characteristic, biodiversity, energy resources, ecosystem, environmental pollution, and global warming topics. The research was conducted due to the important of critical thinking measurement to get the current skill description as the basic consideration for further critical thinking skill improvement in lower secondary science. The research method used was descriptive. 331 seventh grade students taken from five lower secondary schools in Cirebon were tested to get the critical thinking skill data by using Science Virtual Test as the instrument. Generally, the mean scores on eight Inch’ critical thinking elements and overall score from descriptive statistic reveals a moderate attainments level. Students’ critical thinking skill on biodiversity, energy resources, ecosystem, environmental pollution, and global warming topics are in moderate level. While students’ critical thinking skill on living things characteristic is identified as high level. Students’ experience in thinking critically during science learning process and the characteristic of the topic are emerged as the reason behind the students’ critical thinking skill level on certain science topic.

  18. Numerical simulation of inductive method for determining spatial distribution of critical current density

    NASA Astrophysics Data System (ADS)

    Kamitani, A.; Takayama, T.; Tanaka, A.; Ikuno, S.

    2010-11-01

    The inductive method for measuring the critical current density jC in a high-temperature superconducting (HTS) thin film has been investigated numerically. In order to simulate the method, a non-axisymmetric numerical code has been developed for analyzing the time evolution of the shielding current density. In the code, the governing equation of the shielding current density is spatially discretized with the finite element method and the resulting first-order ordinary differential system is solved by using the 5th-order Runge-Kutta method with an adaptive step-size control algorithm. By using the code, the threshold current IT is evaluated for various positions of a coil. The results of computations show that, near a film edge, the accuracy of the estimating formula for jC is remarkably degraded. Moreover, even the proportional relationship between jC and IT will be lost there. Hence, the critical current density near a film edge cannot be estimated by using the inductive method.

  19. Near-field hazard assessment of March 11, 2011 Japan Tsunami sources inferred from different methods

    USGS Publications Warehouse

    Wei, Y.; Titov, V.V.; Newman, A.; Hayes, G.; Tang, L.; Chamberlin, C.

    2011-01-01

    Tsunami source is the origin of the subsequent transoceanic water waves, and thus the most critical component in modern tsunami forecast methodology. Although impractical to be quantified directly, a tsunami source can be estimated by different methods based on a variety of measurements provided by deep-ocean tsunameters, seismometers, GPS, and other advanced instruments, some in real time, some in post real-time. Here we assess these different sources of the devastating March 11, 2011 Japan tsunami by model-data comparison for generation, propagation and inundation in the near field of Japan. This study provides a comparative study to further understand the advantages and shortcomings of different methods that may be potentially used in real-time warning and forecast of tsunami hazards, especially in the near field. The model study also highlights the critical role of deep-ocean tsunami measurements for high-quality tsunami forecast, and its combination with land GPS measurements may lead to better understanding of both the earthquake mechanisms and tsunami generation process. ?? 2011 MTS.

  20. Measuring change in critical thinking skills of dental students educated in a PBL curriculum.

    PubMed

    Pardamean, Bens

    2012-04-01

    This study measured the change in critical thinking skills of dental students educated in a problem-based learning (PBL) pedagogical method. The quantitative analysis was focused on measuring students' critical thinking skills achievement from their first through third years of dental education at the University of Southern California. This non-experimental evaluation was based on a volunteer sample of ninety-eight dental students who completed a demographics/academic questionnaire and a psychometric assessment known as the Health Sciences Reasoning Test (HSRT). The HSRT produced the overall critical thinking skills score. Additionally, the HSRT generated five subscale scores: analysis, inference, evaluation, deductive reasoning, and inductive reasoning. The results of this study concluded that the students showed no continuous and significant incremental improvement in their overall critical thinking skills score achievement during their PBL-based dental education. Except for the inductive reasoning score, this result was very consistent with the four subscale scores. Moreover, after performing the statistical adjustment on total score and subscale scores, no significant statistical differences were found among the three student groups. However, the results of this study found some aspects of critical thinking achievements that differed by categories of gender, race, English as first language, and education level.

  1. Ultimate pier and contraction scour prediction in cohesive soils at selected bridges in Illinois

    USGS Publications Warehouse

    Straub, Timothy D.; Over, Thomas M.; Domanski, Marian M.

    2013-01-01

    The Scour Rate In COhesive Soils-Erosion Function Apparatus (SRICOS-EFA) method includes an ultimate scour prediction that is the equilibrium maximum pier and contraction scour of cohesive soils over time. The purpose of this report is to present the results of testing the ultimate pier and contraction scour methods for cohesive soils on 30 bridge sites in Illinois. Comparison of the ultimate cohesive and noncohesive methods, along with the Illinois Department of Transportation (IDOT) cohesive soil reduction-factor method and measured scour are presented. Also, results of the comparison of historic IDOT laboratory and field values of unconfined compressive strength of soils (Qu) are presented. The unconfined compressive strength is used in both ultimate cohesive and reduction-factor methods, and knowing how the values from field methods compare to the laboratory methods is critical to the informed application of the methods. On average, the non-cohesive method results predict the highest amount of scour, followed by the reduction-factor method results; and the ultimate cohesive method results predict the lowest amount of scour. The 100-year scour predicted for the ultimate cohesive, noncohesive, and reduction-factor methods for each bridge site and soil are always larger than observed scour in this study, except 12% of predicted values that are all within 0.4 ft of the observed scour. The ultimate cohesive scour prediction is smaller than the non-cohesive scour prediction method for 78% of bridge sites and soils. Seventy-six percent of the ultimate cohesive predictions show a 45% or greater reduction from the non-cohesive predictions that are over 10 ft. Comparing the ultimate cohesive and reduction-factor 100-year scour predictions methods for each bridge site and soil, the scour predicted by the ultimate cohesive scour prediction method is less than the reduction-factor 100-year scour prediction method for 51% of bridge sites and soils. Critical shear stress remains a needed parameter in the ultimate scour prediction for cohesive soils. The unconfined soil compressive strength measured by IDOT in the laboratory was found to provide a good prediction of critical shear stress, as measured by using the erosion function apparatus in a previous study. Because laboratory Qu analyses are time-consuming and expensive, the ability of field-measured Rimac data to estimate unconfined soil strength in the critical shear–soil strength relation was tested. A regression analysis was completed using a historic IDOT dataset containing 366 data pairs of laboratory Qu and field Rimac measurements from common sites with cohesive soils. The resulting equations provide a point prediction of Qu, given any Rimac value with the 90% confidence interval. The prediction equations are not significantly different from the identity Qu = Rimac. The alternative predictions of ultimate cohesive scour presented in this study assume Qu will be estimated using Rimac measurements that include computed uncertainty. In particular, the ultimate cohesive predicted scour is greater than observed scour for the entire 90% confidence interval range for predicting Qu at the bridges and soils used in this study, with the exception of the six predicted values that are all within 0.6 ft of the observed scour.

  2. Critical current density enhancement by phase decomposition of YBa 2Cu 4O 8 into YBa 2Cu 3O 7-σ and CuO

    NASA Astrophysics Data System (ADS)

    Krelaus, J.; Heinemann, K.; Ullmann, B.; Freyhardt, H. C.

    1995-02-01

    Bulk YBa 2Cu 4O 8 (Y-124) is prepared from YBa 2Cu 3O 7-σ (Y-123) and CuO by a powder-metallurgical method. The superconducting features of the Y-124, in particular critical current densities and activation energies, are measured resistively using a four-probe technique and magnetically using a Faraday magnetometer. In a second step the Y-124 is decomposed at high temperatures. The intragranular critical current density is measured at different annealing times, tA, in order to determine and discuss the characteristics of the jc( tA) curves.

  3. Lifetimes in Te 124 : Examining critical-point symmetry in the Te nuclei

    DOE PAGES

    Hicks, S. F.; Vanhoy, J. R.; Burkett, P. G.; ...

    2017-03-27

    The Doppler-shift attenuation method following inelastic neutron scattering was used to determine the lifetimes of nuclear levels to 3.3-MeV excitation in 124Te. Level energies and spins, γ -ray energies and branching ratios, and multipole-mixing ratios were deduced from measured γ-ray angular distributions at incident neutron energies of 2.40 and 3.30 MeV, γ-ray excitation functions, and γγ coincidence measurements. The newly obtained reduced transition probabilities and level energies for 124Te were compared to critical-point symmetry model predictions. The E(5) and β 4 potential critical-point symmetries were also investigated in 122Te and 126Te.

  4. Validation of a Method for Measuring Medical Students' Critical Reflections on Professionalism in Gross Anatomy

    ERIC Educational Resources Information Center

    Wittich, Christopher M.; Pawlina, Wojciech; Drake, Richard L.; Szostek, Jason H.; Reed, Darcy A.; Lachman, Nirusha; McBride, Jennifer M.; Mandrekar, Jayawant N.; Beckman, Thomas J.

    2013-01-01

    Improving professional attitudes and behaviors requires critical self reflection. Research on reflection is necessary to understand professionalism among medical students. The aims of this prospective validation study at the Mayo Medical School and Cleveland Clinic Lerner College of Medicine were: (1) to develop and validate a new instrument for…

  5. A Comprehensive Critique and Review of Published Measures of Acne Severity

    PubMed Central

    Furber, Gareth; Leach, Matthew; Segal, Leonie

    2016-01-01

    Objective: Acne vulgaris is a dynamic, complex condition that is notoriously difficult to evaluate. The authors set out to critically evaluate currently available measures of acne severity, particularly in terms of suitability for use in clinical trials. Design: A systematic review was conducted to identify methods used to measure acne severity, using MEDLINE, CINAHL, Scopus, and Wiley Online. Each method was critically reviewed and given a score out of 13 based on eight quality criteria under two broad groupings of psychometric testing and suitability for research and evaluation. Results: Twenty-four methods for assessing acne severity were identified. Four scales received a quality score of zero, and 11 scored ≤3. The highest rated scales achieved a total score of 6. Six scales reported strong inter-rater reliability (ICC>0.75), and four reported strong intra-rater reliability (ICC>0.75). The poor overall performance of most scales, largely characterized by the absence of reliability testing or evidence for independent assessment and validation indicates that generally, their application in clinical trials is not supported. Conclusion: This review and appraisal of instruments for measuring acne severity supports previously identified concerns regarding the quality of published measures. It highlights the need for a valid and reliable acne severity scale, especially for use in research and evaluation. The ideal scale would demonstrate adequate validation and reliability and be easily implemented for third-party analysis. The development of such a scale is critical to interpreting results of trials and facilitating the pooling of results for systematic reviews and meta-analyses. PMID:27672410

  6. Nuclear Data Activities in Support of the DOE Nuclear Criticality Safety Program

    NASA Astrophysics Data System (ADS)

    Westfall, R. M.; McKnight, R. D.

    2005-05-01

    The DOE Nuclear Criticality Safety Program (NCSP) provides the technical infrastructure maintenance for those technologies applied in the evaluation and performance of safe fissionable-material operations in the DOE complex. These technologies include an Analytical Methods element for neutron transport as well as the development of sensitivity/uncertainty methods, the performance of Critical Experiments, evaluation and qualification of experiments as Benchmarks, and a comprehensive Nuclear Data program coordinated by the NCSP Nuclear Data Advisory Group (NDAG). The NDAG gathers and evaluates differential and integral nuclear data, identifies deficiencies, and recommends priorities on meeting DOE criticality safety needs to the NCSP Criticality Safety Support Group (CSSG). Then the NDAG identifies the required resources and unique capabilities for meeting these needs, not only for performing measurements but also for data evaluation with nuclear model codes as well as for data processing for criticality safety applications. The NDAG coordinates effort with the leadership of the National Nuclear Data Center, the Cross Section Evaluation Working Group (CSEWG), and the Working Party on International Evaluation Cooperation (WPEC) of the OECD/NEA Nuclear Science Committee. The overall objective is to expedite the issuance of new data and methods to the DOE criticality safety user. This paper describes these activities in detail, with examples based upon special studies being performed in support of criticality safety for a variety of DOE operations.

  7. DiffSLc: A graph centrality method to detect essential proteins of a protein-protein interaction network

    USDA-ARS?s Scientific Manuscript database

    Network centrality measures prioritize nodes and edges based on their importance to the network topology. These measures have been helpful in identifying critical genes and proteins in biomolecular networks. The proposed centrality measure DiffSLc uses the number of interactions of a protein and gen...

  8. Determination of the critical surface tension of wetting of minerals treated with surfactants by shear flocculation approach.

    PubMed

    Ozkan, A

    2004-09-15

    This paper contributes the shear flocculation method as a new approach to determine the critical surface tension of wetting of minerals treated with surfactants. This newly developed approach is based on the decrease of the shear flocculation of the mineral suspension, with decreasing of the surface tension of the liquids used. The solution surface tension value at which shear flocculation does not occur can be defined as the critical surface tension of wetting (gamma c) of the mineral. By using the shear flocculation method, the critical surface tensions of wetting (gamma c) for calcite and barite minerals, treated with surfactants, were obtained as 30.9 and 35.0 mN/m, respectively. These values are in good agreement with data reported previously on the same minerals obtained by the contact angle measurement and flotation methods. The chemical agents used for the treatment of calcite and barite particles were sodium oleate and sodium dodecyl sulfate, respectively.

  9. La 2-xSr xCuO 4-δ superconducting samples prepared by the wet-chemical method

    NASA Astrophysics Data System (ADS)

    Loose, A.; Gonzalez, J. L.; Lopez, A.; Borges, H. A.; Baggio-Saitovitch, E.

    2009-10-01

    In this work, we report on the physical properties of good-quality polycrystalline superconducting samples of La 2-xSr xCu 1-yZn yO 4-δ ( y=0, 0.02) prepared by a wet-chemical method, focusing on the temperature dependence of the critical current. Using the wet-chemical method, we were able to produce samples with improved homogeneity compared to the solid-state method. A complete set of samples with several carrier concentrations, ranging from the underdoped (strontium concentration x≈0.05) to the highly overdoped ( x≈0.25) region, were prepared and investigated. The X-ray diffraction analysis, zero-field cooling magnetization and electrical resistivity measurements were reported on earlier. The structural parameters of the prepared samples seem to be slightly modified by the preparation method and their critical temperatures were lower than reported in the literature. The temperature dependence of the critical current was explained by a theoretical model which took the granular structure of the samples into account.

  10. Neural network based automatic limit prediction and avoidance system and method

    NASA Technical Reports Server (NTRS)

    Calise, Anthony J. (Inventor); Prasad, Jonnalagadda V. R. (Inventor); Horn, Joseph F. (Inventor)

    2001-01-01

    A method for performance envelope boundary cueing for a vehicle control system comprises the steps of formulating a prediction system for a neural network and training the neural network to predict values of limited parameters as a function of current control positions and current vehicle operating conditions. The method further comprises the steps of applying the neural network to the control system of the vehicle, where the vehicle has capability for measuring current control positions and current vehicle operating conditions. The neural network generates a map of current control positions and vehicle operating conditions versus the limited parameters in a pre-determined vehicle operating condition. The method estimates critical control deflections from the current control positions required to drive the vehicle to a performance envelope boundary. Finally, the method comprises the steps of communicating the critical control deflection to the vehicle control system; and driving the vehicle control system to provide a tactile cue to an operator of the vehicle as the control positions approach the critical control deflections.

  11. Auto-calibrated scanning-angle prism-type total internal reflection microscopy for nanometer-precision axial position determination and optional variable-illumination-depth pseudo total internal reflection microscopy

    DOEpatents

    Fang, Ning; Sun, Wei

    2015-04-21

    A method, apparatus, and system for improved VA-TIRFM microscopy. The method comprises automatically controlled calibration of one or more laser sources by precise control of presentation of each laser relative a sample for small incremental changes of incident angle over a range of critical TIR angles. The calibration then allows precise scanning of the sample for any of those calibrated angles for higher and more accurate resolution, and better reconstruction of the scans for super resolution reconstruction of the sample. Optionally the system can be controlled for incident angles of the excitation laser at sub-critical angles for pseudo TIRFM. Optionally both above-critical angle and sub critical angle measurements can be accomplished with the same system.

  12. Fiducial marker application method for position alignment of in situ multimodal X-ray experiments and reconstructions

    DOE PAGES

    Shade, Paul A.; Menasche, David B.; Bernier, Joel V.; ...

    2016-03-01

    An evolving suite of X-ray characterization methods are presently available to the materials community, providing a great opportunity to gain new insight into material behavior and provide critical validation data for materials models. Two critical and related issues are sample repositioning during anin situexperiment and registration of multiple data sets after the experiment. To address these issues, a method is described which utilizes a focused ion-beam scanning electron microscope equipped with a micromanipulator to apply gold fiducial markers to samples for X-ray measurements. The method is demonstrated with a synchrotron X-ray experiment involvingin situloading of a titanium alloy tensile specimen.

  13. Superconducting critical temperature under pressure

    NASA Astrophysics Data System (ADS)

    González-Pedreros, G. I.; Baquero, R.

    2018-05-01

    The present record on the critical temperature of a superconductor is held by sulfur hydride (approx. 200 K) under very high pressure (approx. 56 GPa.). As a consequence, the dependence of the superconducting critical temperature on pressure became a subject of great interest and a high number of papers on of different aspects of this subject have been published in the scientific literature since. In this paper, we calculate the superconducting critical temperature as a function of pressure, Tc(P), by a simple method. Our method is based on the functional derivative of the critical temperature with the Eliashberg function, δTc(P)/δα2F(ω). We obtain the needed coulomb electron-electron repulsion parameter, μ*(P) at each pressure in a consistent way by fitting it to the corresponding Tc using the linearized Migdal-Eliashberg equation. This method requires as input the knowledge of Tc at the starting pressure only. It applies to superconductors for which the Migdal-Eliashberg equations hold. We study Al and β - Sn two weak-coupling low-Tc superconductors and Nb, the strong coupling element with the highest critical temperature. For Al, our results for Tc(P) show an excellent agreement with the calculations of Profeta et al. which are known to agree well with experiment. For β - Sn and Nb, we found a good agreement with the experimental measurements reported in several works. This method has also been applied successfully to PdH elsewhere. Our method is simple, computationally light and gives very accurate results.

  14. Focus control enhancement and on-product focus response analysis methodology

    NASA Astrophysics Data System (ADS)

    Kim, Young Ki; Chen, Yen-Jen; Hao, Xueli; Samudrala, Pavan; Gomez, Juan-Manuel; Mahoney, Mark O.; Kamalizadeh, Ferhad; Hanson, Justin K.; Lee, Shawn; Tian, Ye

    2016-03-01

    With decreasing CDOF (Critical Depth Of Focus) for 20/14nm technology and beyond, focus errors are becoming increasingly critical for on-product performance. Current on product focus control techniques in high volume manufacturing are limited; It is difficult to define measurable focus error and optimize focus response on product with existing methods due to lack of credible focus measurement methodologies. Next to developments in imaging and focus control capability of scanners and general tool stability maintenance, on-product focus control improvements are also required to meet on-product imaging specifications. In this paper, we discuss focus monitoring, wafer (edge) fingerprint correction and on-product focus budget analysis through diffraction based focus (DBF) measurement methodology. Several examples will be presented showing better focus response and control on product wafers. Also, a method will be discussed for a focus interlock automation system on product for a high volume manufacturing (HVM) environment.

  15. State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes-The Need for Novel Non-Invasive Techniques.

    PubMed

    Greene, Jacob; Louis, Julien; Korostynska, Olga; Mason, Alex

    2017-02-23

    Muscle glycogen levels have a profound impact on an athlete's sporting performance, thus measurement is vital. Carbohydrate manipulation is a fundamental component in an athlete's lifestyle and is a critical part of elite performance, since it can provide necessary training adaptations. This paper provides a critical review of the current invasive and non-invasive methods for measuring skeletal muscle glycogen levels. These include the gold standard muscle biopsy, histochemical analysis, magnetic resonance spectroscopy, and musculoskeletal high frequency ultrasound, as well as pursuing future application of electromagnetic sensors in the pursuit of portable non-invasive quantification of muscle glycogen. This paper will be of interest to researchers who wish to understand the current and most appropriate techniques in measuring skeletal muscle glycogen. This will have applications both in the lab and in the field by improving the accuracy of research protocols and following the physiological adaptations to exercise.

  16. Measuring the sustainability of a natural system by using multi-criteria distance function methods: Some critical issues.

    PubMed

    Diaz-Balteiro, L; Belavenutti, P; Ezquerro, M; González-Pachón, J; Ribeiro Nobre, S; Romero, C

    2018-05-15

    There is an important body of literature using multi-criteria distance function methods for the aggregation of a battery of sustainability indicators in order to obtain a composite index. This index is considered to be a proxy of the sustainability goodness of a natural system. Although this approach has been profusely used in the literature, it is not exempt from difficulties and potential pitfalls. Thus, in this paper, a significant number of critical issues have been identified showing different procedures capable of avoiding, or at least of mitigating, the inherent potential pitfalls associated with each one. The recommendations made in the paper could increase the theoretical soundness of the multi-criteria distance function methods when this type of approach is applied in the sustainability field, thus increasing the accuracy and realism of the sustainability measurements obtained. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Determination of the Critical Micelle Concentration of Neutral and Ionic Surfactants with Fluorometry, Conductometry, and Surface Tension-A Method Comparison.

    PubMed

    Scholz, Norman; Behnke, Thomas; Resch-Genger, Ute

    2018-01-01

    Micelles are of increasing importance as versatile carriers for hydrophobic substances and nanoprobes for a wide range of pharmaceutical, diagnostic, medical, and therapeutic applications. A key parameter indicating the formation and stability of micelles is the critical micelle concentration (CMC). In this respect, we determined the CMC of common anionic, cationic, and non-ionic surfactants fluorometrically using different fluorescent probes and fluorescence parameters for signal detection and compared the results with conductometric and surface tension measurements. Based upon these results, requirements, advantages, and pitfalls of each method are discussed. Our study underlines the versatility of fluorometric methods that do not impose specific requirements on surfactants and are especially suited for the quantification of very low CMC values. Conductivity and surface tension measurements yield smaller uncertainties particularly for high CMC values, yet are more time- and substance consuming and not suitable for every surfactant.

  18. C-Depth Method to Determine Diffusion Coefficient and Partition Coefficient of PCB in Building Materials.

    PubMed

    Liu, Cong; Kolarik, Barbara; Gunnarsen, Lars; Zhang, Yinping

    2015-10-20

    Polychlorinated biphenyls (PCBs) have been found to be persistent in the environment and possibly harmful. Many buildings are characterized with high PCB concentrations. Knowledge about partitioning between primary sources and building materials is critical for exposure assessment and practical remediation of PCB contamination. This study develops a C-depth method to determine diffusion coefficient (D) and partition coefficient (K), two key parameters governing the partitioning process. For concrete, a primary material studied here, relative standard deviations of results among five data sets are 5%-22% for K and 42-66% for D. Compared with existing methods, C-depth method overcomes the inability to obtain unique estimation for nonlinear regression and does not require assumed correlations for D and K among congeners. Comparison with a more sophisticated two-term approach implies significant uncertainty for D, and smaller uncertainty for K. However, considering uncertainties associated with sampling and chemical analysis, and impact of environmental factors, the results are acceptable for engineering applications. This was supported by good agreement between model prediction and measurement. Sensitivity analysis indicated that effective diffusion distance, contacting time of materials with primary sources, and depth of measured concentrations are critical for determining D, and PCB concentration in primary sources is critical for K.

  19. A Robust Strategy for Total Ionizing Dose Testing of Field Programmable Gate Arrays

    NASA Technical Reports Server (NTRS)

    Wilcox, Edward; Berg, Melanie; Friendlich, Mark; Lakeman, Joseph; KIm, Hak; Pellish, Jonathan; LaBel, Kenneth

    2012-01-01

    We present a novel method of FPGA TID testing that measures propagation delay between flip-flops operating at maximum speed. Measurement is performed on-chip at-speed and provides a key design metric when building system-critical synchronous designs.

  20. Managing Complex IT Security Processes with Value Based Measures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abercrombie, Robert K; Sheldon, Frederick T; Mili, Ali

    2009-01-01

    Current trends indicate that IT security measures will need to greatly expand to counter the ever increasingly sophisticated, well-funded and/or economically motivated threat space. Traditional risk management approaches provide an effective method for guiding courses of action for assessment, and mitigation investments. However, such approaches no matter how popular demand very detailed knowledge about the IT security domain and the enterprise/cyber architectural context. Typically, the critical nature and/or high stakes require careful consideration and adaptation of a balanced approach that provides reliable and consistent methods for rating vulnerabilities. As reported in earlier works, the Cyberspace Security Econometrics System provides amore » comprehensive measure of reliability, security and safety of a system that accounts for the criticality of each requirement as a function of one or more stakeholders interests in that requirement. This paper advocates a dependability measure that acknowledges the aggregate structure of complex system specifications, and accounts for variations by stakeholder, by specification components, and by verification and validation impact.« less

  1. 40 CFR Appendix A to Subpart Mmmm... - Alternative Capture Efficiency and Destruction Efficiency Measurement and Monitoring Procedures...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...

  2. 40 CFR Appendix A to Subpart Mmmm... - Alternative Capture Efficiency and Destruction Efficiency Measurement and Monitoring Procedures...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...

  3. 40 CFR Appendix A to Subpart Mmmm... - Alternative Capture Efficiency and Destruction Efficiency Measurement and Monitoring Procedures...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...

  4. 40 CFR Appendix A to Subpart Mmmm... - Alternative Capture Efficiency and Destruction Efficiency Measurement and Monitoring Procedures...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...

  5. 40 CFR Appendix A to Subpart Mmmm... - Alternative Capture Efficiency and Destruction Efficiency Measurement and Monitoring Procedures...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... change from job to job. The air balance in magnet wire ovens is critical to product quality. Magnet wire... Method D5291-02, “Standard Test Methods for Instrumental Determination of Carbon, Hydrogen, and Nitrogen...

  6. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption

    NASA Astrophysics Data System (ADS)

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (˜100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ˜0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  7. Combination volumetric and gravimetric sorption instrument for high accuracy measurements of methane adsorption.

    PubMed

    Burress, Jacob; Bethea, Donald; Troub, Brandon

    2017-05-01

    The accurate measurement of adsorbed gas up to high pressures (∼100 bars) is critical for the development of new materials for adsorbed gas storage. The typical Sievert-type volumetric method introduces accumulating errors that can become large at maximum pressures. Alternatively, gravimetric methods employing microbalances require careful buoyancy corrections. In this paper, we present a combination gravimetric and volumetric system for methane sorption measurements on samples between ∼0.5 and 1 g. The gravimetric method described requires no buoyancy corrections. The tandem use of the gravimetric method allows for a check on the highest uncertainty volumetric measurements. The sources and proper calculation of uncertainties are discussed. Results from methane measurements on activated carbon MSC-30 and metal-organic framework HKUST-1 are compared across methods and within the literature.

  8. Analysis of a boron-carbide-drum-controlled critical reactor experiment

    NASA Technical Reports Server (NTRS)

    Mayo, W. T.

    1972-01-01

    In order to validate methods and cross sections used in the neutronic design of compact fast-spectrum reactors for generating electric power in space, an analysis of a boron-carbide-drum-controlled critical reactor was made. For this reactor the transport analysis gave generally satisfactory results. The calculated multiplication factor for the most detailed calculation was only 0.7-percent Delta k too high. Calculated reactivity worth of the control drums was $11.61 compared to measurements of $11.58 by the inverse kinetics methods and $11.98 by the inverse counting method. Calculated radial and axial power distributions were in good agreement with experiment.

  9. Notes on Experiments.

    ERIC Educational Resources Information Center

    Physics Education, 1989

    1989-01-01

    Introduced are two experiments: radon detection method shows real data using vacuum cleaner, soft toilet paper, and Geiger-Muller tube; critical potentials measurement describes the operation of Teltron tube with VELA. (YP)

  10. Use of Multi-Response Format Test in the Assessment of Medical Students’ Critical Thinking Ability

    PubMed Central

    Mafinejad, Mahboobeh Khabaz; Monajemi, Alireza; Jalili, Mohammad; Soltani, Akbar; Rasouli, Javad

    2017-01-01

    Introduction To evaluate students critical thinking skills effectively, change in assessment practices is must. The assessment of a student’s ability to think critically is a constant challenge, and yet there is considerable debate on the best assessment method. There is evidence that the intrinsic nature of open and closed-ended response questions is to measure separate cognitive abilities. Aim To assess critical thinking ability of medical students by using multi-response format of assessment. Materials and Methods A cross-sectional study was conducted on a group of 159 undergraduate third-year medical students. All the participants completed the California Critical Thinking Skills Test (CCTST) consisting of 34 multiple-choice questions to measure general critical thinking skills and a researcher-developed test that combines open and closed-ended questions. A researcher-developed 48-question exam, consisting of 8 short-answers and 5 essay questions, 19 Multiple-Choice Questions (MCQ), and 16 True-False (TF) questions, was used to measure critical thinking skills. Correlation analyses were performed using Pearson’s coefficient to explore the association between the total scores of tests and subtests. Results One hundred and fifty-nine students participated in this study. The sample comprised 81 females (51%) and 78 males (49%) with an age range of 20±2.8 years (mean 21.2 years). The response rate was 64.1%. A significant positive correlation was found between types of questions and critical thinking scores, of which the correlations of MCQ (r=0.82) and essay questions (r=0.77) were strongest. The significant positive correlations between multi-response format test and CCTST’s subscales were seen in analysis, evaluation, inference and inductive reasoning. Unlike CCTST subscales, multi-response format test have weak correlation with CCTST total score (r=0.45, p=0.06). Conclusion This study highlights the importance of considering multi-response format test in the assessment of critical thinking abilities of medical students by using both open and closed-ended response questions. PMID:29207742

  11. Measuring Thermal Diffusivity Of A High-Tc Superconductor

    NASA Technical Reports Server (NTRS)

    Powers, Charles E.; Oh, Gloria; Leidecker, Henning

    1992-01-01

    Technique for measuring thermal diffusivity of superconductor of high critical temperature based on Angstrom's temperature-wave method. Peltier junction generates temperature oscillations, which propagate with attenuation up specimen. Thermal diffusivity of specimen calculated from distance between thermocouples and amplitudes and phases of oscillatory components of thermocouple readings.

  12. Generalization of the swelling method to measure the intrinsic curvature of lipids

    NASA Astrophysics Data System (ADS)

    Barragán Vidal, I. A.; Müller, M.

    2017-12-01

    Via computer simulation of a coarse-grained model of two-component lipid bilayers, we compare two methods of measuring the intrinsic curvatures of the constituting monolayers. The first one is a generalization of the swelling method that, in addition to the assumption that the spontaneous curvature linearly depends on the composition of the lipid mixture, incorporates contributions from its elastic energy. The second method measures the effective curvature-composition coupling between the apposing leaflets of bilayer structures (planar bilayers or cylindrical tethers) to extract the spontaneous curvature. Our findings demonstrate that both methods yield consistent results. However, we highlight that the two-leaflet structure inherent to the latter method has the advantage of allowing measurements for mixed lipid systems up to their critical point of demixing as well as in the regime of high concentration (of either species).

  13. A Comparative Study of a Research-Oriented High School Advanced Biology Class and a Conventional Textbook-Centered Class.

    ERIC Educational Resources Information Center

    Smith, Alva Nelson

    Two instructional methods were identified and compared to determine if any significant differences could be noted on three criterion measures. Measurements were conducted in the areas of achievement in biology, science attitudes, and critical thinking ability. Student ability was measured using pre-tests and the Scholastic Aptitude Test. Students…

  14. Critical thinking dispositions of nursing students in Asian and non-Asian countries: a literature review.

    PubMed

    Salsali, Mahvash; Tajvidi, Mansooreh; Ghiyasvandian, Shahrzad

    2013-09-26

    Critical thinking disposition represents an inclination of a person to use possessed skills in relation to critical thinking. The trend of critical thinking has been described as inner motivation to solve problems and make decisions by thinking. In nursing as a practical profession, the concept of critical thinking dispositions is important component in helping to manage complex health situations and to deal with patient issues effectively. Willingness to think critically is a prerequisite for safe and subtly performance. The results of studies show critical thinking dispositions of nursing students in Asian countries are different from non-Asian countries. Aim of this literature review was to compare critical thinking dispositions of nursing students in Asian and non-Asian countries. Literature review was done in English and Persian databases. The results showed of the 795 articles published in English and Persian language that studied critical thinking, 73 ones studied critical thinking skills and dispositions in nursing education, and relationship between teaching methods and critical thinking skills and dispositions in nursing education of different countries. Fifteen of seventy three articles assessed critical thinking dispositions in nursing students. Limited studies showed that the Asian nursing students had mostly undermining score of the critical thinking dispositions, while non-Asian countries tend to positive scores. The reasons for these differences could be due to issues such as environmental, educational methods and cultural differences. However, future studies should measure critical thinking disposition by discipline-based tools.

  15. Critical Thinking Dispositions of Nursing Students in Asian and Non-Asian Countries: A Literature Review

    PubMed Central

    Salsali, Mahvash; Tajvidi, Mansooreh; Ghiyasvandian, Shahrzad

    2013-01-01

    Critical thinking disposition represents an inclination of a person to use possessed skills in relation to critical thinking. The trend of critical thinking has been described as inner motivation to solve problems and make decisions by thinking. In nursing as a practical profession, the concept of critical thinking dispositions is important component in helping to manage complex health situations and to deal with patient issues effectively. Willingness to think critically is a prerequisite for safe and subtly performance. The results of studies show critical thinking dispositions of nursing students in Asian countries are different from non-Asian countries. Aim of this literature review was to compare critical thinking dispositions of nursing students in Asian and non-Asian countries. Literature review was done in English and Persian databases. The results showed of the 795 articles published in English and Persian language that studied critical thinking, 73 ones studied critical thinking skills and dispositions in nursing education, and relationship between teaching methods and critical thinking skills and dispositions in nursing education of different countries. Fifteen of seventy three articles assessed critical thinking dispositions in nursing students. Limited studies showed that the Asian nursing students had mostly undermining score of the critical thinking dispositions, while non-Asian countries tend to positive scores. The reasons for these differences could be due to issues such as environmental, educational methods and cultural differences. However, future studies should measure critical thinking disposition by discipline-based tools. PMID:24171885

  16. Measuring Nanomaterial Release from Carbon Nanotube Composites: Review of the State of the Science

    NASA Astrophysics Data System (ADS)

    Harper, Stacey; Wohlleben, Wendel; Doa, Maria; Nowack, Bernd; Clancy, Shaun; Canady, Richard; Maynard, Andrew

    2015-05-01

    Hazard studies of “as-produced” nanomaterials are increasingly available, yet a critical gap exists in exposure science that may impede safe development of nanomaterials. The gap is that we do not understand what is actually released because nanomaterials can change when released in ways that are not understood. We also generally do not have methods capable of quantitatively measuring what is released to support dose assessment. This review presents a case study of multi-walled carbon nanotubes (MWCNTs) for the measurement challenge to bridge this gap. As the use and value of MWCNTs increases, methods to measure what is released in ways relevant to risk evaluation are critically needed if products containing these materials are to be economically, environmentally, and socially sustainable. This review draws on the input of over 50 experts engaged in a program of workshops and technical report writing to address the release of MWCNTs from nanocomposite materials across their life cycle. The expert analyses reveals that new and sophisticated methods are required to measure and assess MWCNT exposures for realistic exposure scenarios. Furthermore, method requirements vary with the materials and conditions of release across life cycle stages of products. While review shows that the likelihood of significant release of MWCNTs appears to be low for many stages of composite life cycle, measurement methods are needed so that exposures from MWCNT-composites are understood and managed. In addition, there is an immediate need to refocus attention from study of “as-produced” nanomaterials to coordinated research on actual release scenarios.

  17. Nurse educators' critical thinking: A mixed methods exploration.

    PubMed

    Raymond, Christy; Profetto-McGrath, Joanne; Myrick, Florence; Strean, William B

    2018-07-01

    Nurse educator's critical thinking remains unexamined as a key factor in the development of students' critical thinking. The objective of this study is to understand how nurse educators reveal their critical thinking in the clinical setting while supervising students. This study uses a single-phase triangulation mixed methods design with multiple data gathering techniques. Participants for this study are clinical nurse educators from a large Western Canadian baccalaureate nursing program who teach 2nd or 3rd year students in medical-surgical settings. Participants for this study completed a demographic survey, the California Critical Thinking Skills Test (CCTST), the California Critical Thinking Disposition Inventory (CCTDI), participant observation in a clinical practice setting, and semi-structured interviews. The results from the California Critical Thinking assessments (CCTST and CCTDI) show that participants are positively inclined and have a moderate to strong ability to think critically, similar to other studies. Participants find it difficult to describe how they reveal their critical thinking in the clinical setting, yet all participants use role modeling and questioning to share their critical thinking with students. When the quantitative and qualitative results are compared, it is apparent that the confidence in reasoning subscale of the California Critical Thinking Skills Test is higher in those educators who more frequently demonstrate and voice engagement in reflective activities. Dispositions associated with critical thinking, as measured by the California Critical Thinking Disposition Inventory, are more easily observed compared to critical thinking skills. This study is a beginning exploration of nurse educators' critical thinking-in-action. Our mixed methods approach uncovers a valuable approach to understanding the complexity of nurse educators' critical thinking. Further study is needed to uncover how nurse educators' can specifically enact their thinking abilities to support student learning in the clinical setting. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  18. Statistical properties of the Jukes-Holmquist method of estimating the number of nucleotide substitutions: reply to Holmquist and Conroy's criticism.

    PubMed

    Nei, M; Tateno, Y

    1981-01-01

    Conducting computer simulations, Nei and Tateno (1978) have shown that Jukes and Holmquist's (1972) method of estimating the number of nucleotide substitutions tends to give an overestimate and the estimate obtained has a large variance. Holmquist and Conroy (1980) repeated some parts of our simulation and claim that the overestimation of nucleotide substitutions in our paper occurred mainly because we used selected data. Examination of Holmquist and Conroy's simulation indicates that their results are essentially the same as ours when the Jukes-Holmquist method is used, but since they used a different method of computation their estimates of nucleotide substitutions differed substantially from ours. Another problem in Holmquist and Conroy's Letter is that they confused the expected number of nucleotide substitution with the number in a sample. This confusion has resulted in a number of unnecessary arguments. They also criticized our X2 measure, but this criticism is apparently due to a misunderstanding of the assumptions of our method and a failure to use our method in the way we described. We believe that our earlier conclusions remain unchanged.

  19. A MULTI-RESIDUE METHOD FOR THE ANALYSIS OF INSECTICIDES COLLECTED ON COTTON SURFACE WIPES

    EPA Science Inventory

    A method was developed for the extraction, clean-up, and analysis of multiple pesticides from cotton wipe media used in human exposure studies to collect residues from residential hard surfaces. Measurements of pesticides are critical for estimating dermal and indirect ingestion ...

  20. Critical evaluations of vegetation cover measurement techniques: a response to Thacker et al. (2015)

    USDA-ARS?s Scientific Manuscript database

    Comparison studies are necessary to reconcile methods that have arisen among disparate rangeland monitoring programs. However, Thacker et al.'s study comparing Daubenmire frame (DF) and line-point intercept (LPI) methods for estimating vegetation cover ignores definitional differences between what t...

  1. Ultrasensitive low noise voltage amplifier for spectral analysis.

    PubMed

    Giusi, G; Crupi, F; Pace, C

    2008-08-01

    Recently we have proposed several voltage noise measurement methods that allow, at least in principle, the complete elimination of the noise introduced by the measurement amplifier. The most severe drawback of these methods is that they require a multistep measurement procedure. Since environmental conditions may change in the different measurement steps, the final result could be affected by these changes. This problem is solved by the one-step voltage noise measurement methodology based on a novel amplifier topology proposed in this paper. Circuit implementations for the amplifier building blocks based on operational amplifiers are critically discussed. The proposed approach is validated through measurements performed on a prototype circuit.

  2. Critical current densities of Jelly-Roll and powder metallurgy Nb{sub 3}Al wires as a function of temperature and magnetic field

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thieme, C.L.H.; Kim, J.B.; Takayasu, M.

    Critical current densities of multi-filamentary Nb{sub 3}Al wire made with the Jelly-Roll process (JR) and mono-core powder metallurgy process (PM) wire were measured as a function of temperature and magnetic field. The temperature dependence of the resistive critical field B{sub c2} was measured in PM wires. There is a significant difference between these resistive B{sub c2} values and the ones determined by Kramer plots. The field dependence of the critical current depends on the manufacturing method. In general, it follows a relationship that falls between pure Kramer and one where the pinning force is inversely proportional with B{sup 2}. Inmore » contrast with Nb{sub 3}Sn no maximum in the bulk pinning force is observed down to 3 T (0.15MxB{sub c2}).« less

  3. Tightness of the Ising-Kac Model on the Two-Dimensional Torus

    NASA Astrophysics Data System (ADS)

    Hairer, Martin; Iberti, Massimo

    2018-05-01

    We consider the sequence of Gibbs measures of Ising models with Kac interaction defined on a periodic two-dimensional discrete torus near criticality. Using the convergence of the Glauber dynamic proven by Mourrat and Weber (Commun Pure Appl Math 70:717-812, 2017) and a method by Tsatsoulis and Weber employed in (arXiv:1609.08447 2016), we show tightness for the sequence of Gibbs measures of the Ising-Kac model near criticality and characterise the law of the limit as the Φ ^4_2 measure on the torus. Our result is very similar to the one obtained by Cassandro et al. (J Stat Phys 78(3):1131-1138, 1995) on Z^2, but our strategy takes advantage of the dynamic, instead of correlation inequalities. In particular, our result covers the whole critical regime and does not require the large temperature/large mass/small coupling assumption present in earlier results.

  4. Fractal analysis of GPS time series for early detection of disastrous seismic events

    NASA Astrophysics Data System (ADS)

    Filatov, Denis M.; Lyubushin, Alexey A.

    2017-03-01

    A new method of fractal analysis of time series for estimating the chaoticity of behaviour of open stochastic dynamical systems is developed. The method is a modification of the conventional detrended fluctuation analysis (DFA) technique. We start from analysing both methods from the physical point of view and demonstrate the difference between them which results in a higher accuracy of the new method compared to the conventional DFA. Then, applying the developed method to estimate the measure of chaoticity of a real dynamical system - the Earth's crust, we reveal that the latter exhibits two distinct mechanisms of transition to a critical state: while the first mechanism has already been known due to numerous studies of other dynamical systems, the second one is new and has not previously been described. Using GPS time series, we demonstrate efficiency of the developed method in identification of critical states of the Earth's crust. Finally we employ the method to solve a practically important task: we show how the developed measure of chaoticity can be used for early detection of disastrous seismic events and provide a detailed discussion of the numerical results, which are shown to be consistent with outcomes of other researches on the topic.

  5. Research on criticality analysis method of CNC machine tools components under fault rate correlation

    NASA Astrophysics Data System (ADS)

    Gui-xiang, Shen; Xian-zhuo, Zhao; Zhang, Ying-zhi; Chen-yu, Han

    2018-02-01

    In order to determine the key components of CNC machine tools under fault rate correlation, a system component criticality analysis method is proposed. Based on the fault mechanism analysis, the component fault relation is determined, and the adjacency matrix is introduced to describe it. Then, the fault structure relation is hierarchical by using the interpretive structure model (ISM). Assuming that the impact of the fault obeys the Markov process, the fault association matrix is described and transformed, and the Pagerank algorithm is used to determine the relative influence values, combined component fault rate under time correlation can obtain comprehensive fault rate. Based on the fault mode frequency and fault influence, the criticality of the components under the fault rate correlation is determined, and the key components are determined to provide the correct basis for equationting the reliability assurance measures. Finally, taking machining centers as an example, the effectiveness of the method is verified.

  6. An Evaluation of Argument Mapping as a Method of Enhancing Critical Thinking Performance in E-Learning Environments

    ERIC Educational Resources Information Center

    Dwyer, Christopher P.; Hogan, Michael J.; Stewart, Ian

    2012-01-01

    The current research examined the effects of a critical thinking (CT) e-learning course taught through argument mapping (AM) on measures of CT ability. Seventy-four undergraduate psychology students were allocated to either an AM-infused CT e-learning course or a no instruction control group and were tested both before and after an 8-week…

  7. Formula Feedback and Central Cities: The Case of the Comprehensive Employment and Training Act.

    ERIC Educational Resources Information Center

    Jones, E. Terrence; Phares, Donald

    1978-01-01

    This study critically examines the measurement of the Comprehesive Employment and Training Act's key allocation variable, unemployment. The analysis indicates (1) unemployment rates are higher than government estimates and (2) methods used to measure state and local umemployment have several weaknesses. (Author/RLV)

  8. Optimizing efficiency of height modeling for extensive forest inventories.

    Treesearch

    T.M. Barrett

    2006-01-01

    Although critical to monitoring forest ecosystems, inventories are expensive. This paper presents a generalizable method for using an integer programming model to examine tradeoffs between cost and estimation error for alternative measurement strategies in forest inventories. The method is applied to an example problem of choosing alternative height-modeling strategies...

  9. Measuring School Functioning in Students with Chronic Fatigue Syndrome: A Systematic Review

    ERIC Educational Resources Information Center

    Tollit, Michelle; Politis, Jennifer; Knight, Sarah

    2018-01-01

    Background: It is often surmised that school functioning is significantly impacted in chronic fatigue syndrome (CFS); however, how this phenomenon manifests itself has rarely been characterized. Methods: This systematic review synthesized and critically appraised methods, constructs, and instruments used to assess school functioning in students…

  10. Critical behavior near the ferromagnetic phase transition in double perovskite Nd2NiMnO6

    NASA Astrophysics Data System (ADS)

    Ali, Anzar; Sharma, G.; Singh, Yogesh

    2018-05-01

    The knowledge of critical exponents plays a crucial role in trying to understand the interaction mechanism near a phase transition. In this report, we present a detailed study of the critical behaviour near the ferromagnetic (FM) transition (TC ˜ 193 K) in Nd2NiMnO6 using the temperature and magnetic field dependent isothermal magnetisation measurements. We used various analysis methods such as Arrott plot, modified Arrott plot, and Kouvel-Fisher plot to estimate the critical parameters. The magnetic critical parameters β = 0.49±0.02, γ = 1.05±0.04 and critical isothermal parameter δ = 3.05±0.02 are in excellent agreement with Widom scaling. The critical parameters analysis emphasizes that mean field interaction is the mechanism driving the FM transition in Nd2NiMnO6.

  11. The validation of science virtual test to assess 7th grade students’ critical thinking on matter and heat topic (SVT-MH)

    NASA Astrophysics Data System (ADS)

    Sya’bandari, Y.; Firman, H.; Rusyati, L.

    2018-05-01

    The method used in this research was descriptive research for profiling the validation of SVT-MH to measure students’ critical thinking on matter and heat topic in junior high school. The subject is junior high school students of 7th grade (13 years old) while science teacher and expert as the validators. The instruments that used as a tool to obtain the data are rubric expert judgment (content, media, education) and rubric of readability test. There are four steps to validate SVT-MH in 7th grade Junior High School. These steps are analysis of core competence and basic competence based on Curriculum 2013, expert judgment (content, media, education), readability test and trial test (limited and larger trial test). The instrument validation resulted 30 items that represent 8 elements and 21 sub-elements to measure students’ critical thinking based on Inch in matter and heat topic. The alpha Cronbach (α) is 0.642 which means that the instrument is sufficient to measure students’ critical thinking matter and heat topic.

  12. Evaluation of critical shear stresses for consolidated cohesive sediment depositions by using PIV compared with field measurements

    NASA Astrophysics Data System (ADS)

    Harb, Gabriele; Haun, Stefan

    2013-04-01

    Reservoir sedimentation is a common problem today. Due to the reduced flow velocities, turbulences and bed shear stresses the transported sediment load start to settle. These depositions reduce the worldwide average storage capacity in the range of about 1% per year. However, depending on the climate conditions and the geology in the catchment area this value may vary strongly. Therefore sediment management tasks, especially the removal of already accumulated sediments, have to be developed for each reservoir separately. The critical bed shear stress is a key parameter used to evaluate the different management tasks and depend strongly on the grain size distribution of the inflowing sediments. However, depositions which contain fine particles like clay and silt increase the critical bed shear stress due to occurring cohesive forces and the use of the Shield curve for evaluating the critical shear stress is no longer valid. Additional data is required for estimating the valid critical shear stress at the reservoir bed. In this study the critical shear stress was evaluated for cohesive sediment samples, taken from two different reservoirs, in a flume in the laboratory. The sediment samples were placed in an installed double bottom in the research flume and the discharge was increased stepwise until mass erosion took place (determined by visual inspection). A 2D PIV device was used to measure the flow conditions (velocities and turbulences) over the sediment sample. The obtained values were used to calculate the bed shear stress for the specific discharge rate by the gravity method and the Reynolds stress method. The results of both methods showed good agreement in the comparison of the values, what indicates that nearly uniform flow conditions occurred in the flume. The results from this study showed that the behaviour of natural cohesive sediments depend strongly on the natural conditions as a result of physical, chemical and biological processes. In this case especially the effect of the layer structure in the sediment samples was controlling the erosion mechanism. The results of the experiments showed also that the obtained average shear stress was above most of the values found in previous conducted studies, which may be explained by consolidation effects in the reservoirs. Additional conducted vane strength measurements have been carried out in situ. The in the field obtained vane strength values were set in relation to the critical shear stresses derived by the experimental tests from the laboratory and to data from a previous conducted study to develop a new relation function. This function may be used in future studies for a rough estimation of the critical shear stress, based on in situ measured vane strength values.

  13. The Capability Approach: A Critical Review of Its Application in Health Economics.

    PubMed

    Karimi, Milad; Brazier, John; Basarir, Hasan

    The capability approach is an approach to assessing well-being developed by Amartya Sen. Interest in this approach has resulted in several attempts to develop questionnaires to measure and value capability at an individual level in health economics. This commentary critically reviews the ability of these questionnaires to measure and value capability. It is argued that the method used in the questionnaires to measure capability will result in a capability set that is an inaccurate description of the individual's true capability set. The measured capability set will either represent only one combination and ignore the value of choice in the capability set, or represent one combination that is not actually achievable by the individual. In addition, existing methods of valuing capability may be inadequate because they do not consider that capability is a set. It may be practically more feasible to measure and value capability approximately rather than directly. Suggestions are made on how to measure and value an approximation to capability, but further research is required to implement the suggestions. Copyright © 2016 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  14. Nuclear accident dosimetry intercomparison studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sims, C.S.

    1989-09-01

    Twenty-two nuclear accident dosimetry intercomparison studies utilizing the fast-pulse Health Physics Research Reactor at the Oak Ridge National Laboratory have been conducted since 1965. These studies have provided a total of 62 different organizations a forum for discussion of criticality accident dosimetry, an opportunity to test their neutron and gamma-ray dosimetry systems under a variety of simulated criticality accident conditions, and the experience of comparing results with reference dose values as well as with the measured results obtained by others making measurements under identical conditions. Sixty-nine nuclear accidents (27 with unmoderated neutron energy spectra and 42 with eight different shieldedmore » spectra) have been simulated in the studies. Neutron doses were in the 0.2-8.5 Gy range and gamma doses in the 0.1-2.0 Gy range. A total of 2,289 dose measurements (1,311 neutron, 978 gamma) were made during the intercomparisons. The primary methods of neutron dosimetry were activation foils, thermoluminescent dosimeters, and blood sodium activation. The main methods of gamma dose measurement were thermoluminescent dosimeters, radiophotoluminescent glass, and film. About 68% of the neutron measurements met the accuracy guidelines (+/- 25%) and about 52% of the gamma measurements met the accuracy criterion (+/- 20%) for accident dosimetry.« less

  15. Determination of Critical Parameters Based on the Intensity of Transmitted Light Around Gas-Liquid Interface: Critical Parameters of CO

    NASA Astrophysics Data System (ADS)

    Nakayama, Masaki; Katano, Hiroaki; Sato, Haruki

    2014-05-01

    A precise determination of the critical temperature and density for technically important fluids would be possible on the basis of the digital image for the visual observation of the phase boundary in the vicinity of the critical point since the sensitivity and resolution are higher than those of naked eyes. In addition, the digital image can avoid the personal uncertainty of an observer. A strong density gradient occurs in a sample cell at the critical point due to gravity. It was carefully assessed to determine the critical density, where the density profile in the sample cell can be observed from the luminance profile of a digital image. The density-gradient profile becomes symmetric at the critical point. One of the best fluids, whose thermodynamic properties have been measured with the highest reliability among technically important fluids, would be carbon dioxide. In order to confirm the reliability of the proposed method, the critical temperature and density of carbon dioxide were determined using the digital image. The critical temperature and density values of carbon dioxide are ( and ( kg m, respectively. The critical temperature and density values agree with the existing best values within estimated uncertainties. The reliability of the method was confirmed. The critical pressure, 7.3795 MPa, corresponding to the determined critical temperature of 304.143 K is also proposed. A new set of parameters for the vapor-pressure equation is also provided.

  16. A method for development of efficient 3D models for neutronic calculations of ASTRA critical facility using experimental information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balanin, A. L.; Boyarinov, V. F.; Glushkov, E. S.

    The application of experimental information on measured axial distributions of fission reaction rates for development of 3D numerical models of the ASTRA critical facility taking into account azimuthal asymmetry of the assembly simulating a HTGR with annular core is substantiated. Owing to the presence of the bottom reflector and the absence of the top reflector, the application of 2D models based on experimentally determined buckling is impossible for calculation of critical assemblies of the ASTRA facility; therefore, an alternative approach based on the application of the extrapolated assembly height is proposed. This approach is exemplified by the numerical analysis ofmore » experiments on measurement of efficiency of control rods mockups and protection system (CPS).« less

  17. Comparison of Instream and Laboratory Methods of Measuring Sediment Oxygen Demand

    USGS Publications Warehouse

    Hall, Dennis C.; Berkas, Wayne R.

    1988-01-01

    Sediment oxygen demand (SOD) was determined at three sites in a gravel-bottomed central Missouri stream by: (1) two variations of an instream method, and (2) a laboratory method. SOD generally was greatest by the instream methods, which are considered more accurate, and least by the laboratory method. Disturbing stream sediment did not significantly decrease SOD by the instream method. Temperature ranges of up to 12 degree Celsius had no significant effect on the SOD. In the gravel-bottomed stream, the placement of chambers was critical to obtain reliable measurements. SOD rates were dependent on the method; therefore, care should be taken in comparing SOD data obtained by different methods. There is a need for a carefully researched standardized method for SOD determinations.

  18. Vehicle response-based track geometry assessment using multi-body simulation

    NASA Astrophysics Data System (ADS)

    Kraft, Sönke; Causse, Julien; Coudert, Frédéric

    2018-02-01

    The assessment of the geometry of railway tracks is an indispensable requirement for safe rail traffic. Defects which represent a risk for the safety of the train have to be identified and the necessary measures taken. According to current standards, amplitude thresholds are applied to the track geometry parameters measured by recording cars. This geometry-based assessment has proved its value but suffers from the low correlation between the geometry parameters and the vehicle reactions. Experience shows that some defects leading to critical vehicle reactions are underestimated by this approach. The use of vehicle responses in the track geometry assessment process allows identifying critical defects and improving the maintenance operations. This work presents a vehicle response-based assessment method using multi-body simulation. The choice of the relevant operation conditions and the estimation of the simulation uncertainty are outlined. The defects are identified from exceedances of track geometry and vehicle response parameters. They are then classified using clustering methods and the correlation with vehicle response is analysed. The use of vehicle responses allows the detection of critical defects which are not identified from geometry parameters.

  19. A thermodynamic study of the amphiphilic phenothiazine drug thioridazine hydrochloride in water/ethanol solvent

    NASA Astrophysics Data System (ADS)

    Cheema, Mohammad Arif; Barbosa, Silvia; Taboada, Pablo; Castro, Emilio; Siddiq, Mohammad; Mosquera, Víctor

    2006-09-01

    The thermodynamic properties of aqueous solutions of the tricyclic antidepressant amphiphilic phenothiazine drug thioridazine hydrochloride in the temperature range 20-50 °C and in the presence of ethanol have been measured. The phenothiazine tranquillizing drugs have interesting association characteristics that derive from their rigid, tricyclic hydrophobic groups. Thioridazine hydrochloride is a drug used in treatment of mental illness that shows side effects. Therefore, it is interesting to study the change of its physico-chemical properties with temperature and with the surrounding environment to understand the action mechanism of the drug. Densities, conductivities, and surface tension were measured to obtain surface and bulk solution properties. Critical concentrations, cc, at different temperatures and in the presence of ethanol, and partition coefficients, K, have been calculated, the latter using an indirect method based in the pseudophase model with the help of apparent molar volume data. This method has the advantage that allows calculating the distribution coefficients at solubilizate concentrations below the saturation. Conductivity data show two critical concentrations. The second critical concentration is not clear by density data. The effect of the alcohol is to decrease the first critical concentration due to a decrease in headgroup repulsion. The molar apparent volumes at infinite dilution and in the aggregate in water and in presence of ethanol have been also obtained.

  20. Transthoracic echocardiography: an accurate and precise method for estimating cardiac output in the critically ill patient.

    PubMed

    Mercado, Pablo; Maizel, Julien; Beyls, Christophe; Titeca-Beauport, Dimitri; Joris, Magalie; Kontar, Loay; Riviere, Antoine; Bonef, Olivier; Soupison, Thierry; Tribouilloy, Christophe; de Cagny, Bertrand; Slama, Michel

    2017-06-09

    Cardiac output (CO) monitoring is a valuable tool for the diagnosis and management of critically ill patients. In the critical care setting, few studies have evaluated the level of agreement between CO estimated by transthoracic echocardiography (CO-TTE) and that measured by the reference method, pulmonary artery catheter (CO-PAC). The objective of the present study was to evaluate the precision and accuracy of CO-TTE relative to CO-PAC and the ability of transthoracic echocardiography to track variations in CO, in critically ill mechanically ventilated patients. Thirty-eight mechanically ventilated patients fitted with a PAC were included in a prospective observational study performed in a 16-bed university hospital ICU. CO-PAC was measured via intermittent thermodilution. Simultaneously, a second investigator used standard-view TTE to estimate CO-TTE as the product of stroke volume and the heart rate obtained during the measurement of the subaortic velocity time integral. Sixty-four pairs of CO-PAC and CO-TTE measurements were compared. The two measurements were significantly correlated (r = 0.95; p < 0.0001). The median bias was 0.2 L/min, the limits of agreement (LOAs) were -1.3 and 1.8 L/min, and the percentage error was 25%. The precision was 8% for CO-PAC and 9% for CO-TTE. Twenty-six pairs of ΔCO measurements were compared. There was a significant correlation between ΔCO-PAC and ΔCO-TTE (r = 0.92; p < 0.0001). The median bias was -0.1 L/min and the LOAs were -1.3 and +1.2 L/min. With a 15% exclusion zone, the four-quadrant plot had a concordance rate of 94%. With a 0.5 L/min exclusion zone, the polar plot had a mean polar angle of 1.0° and a percentage error LOAs of -26.8 to 28.8°. The concordance rate was 100% between 30 and -30°. When using CO-TTE to detect an increase in ΔCO-PAC of more than 10%, the area under the receiving operating characteristic curve (95% CI) was 0.82 (0.62-0.94) (p < 0.001). A ΔCO-TTE of more than 8% yielded a sensitivity of 88% and specificity of 66% for detecting a ΔCO-PAC of more than 10%. In critically ill mechanically ventilated patients, CO-TTE is an accurate and precise method for estimating CO. Furthermore, CO-TTE can accurately track variations in CO.

  1. The wood cylinder method of measuring forest inflammability

    Treesearch

    H. T. Gisborne

    1933-01-01

    The best test of the practicability of any new method or device is the actual trial by numerous users who are interested only in the end product, and who have no special interest in the means employed to reach that end. Such users are not inclined to give the new method the advantage of any doubts, and they are particularly critical of the method or device insofar as...

  2. Pilot-scale concept of real-time wind speed-matching wind tunnel for measurements of gaseous emissions

    USDA-ARS?s Scientific Manuscript database

    Comprehensive control of odors, hydrogen sulfide (H2S), ammonia (NH3) and odorous volatile organic compound (VOC) emissions associated with animal production is a critical need. Current methods utilizing wind tunnels and flux chambers for measurements of gaseous emissions from area sources such as f...

  3. Measurement of air-surface exchange of speciated nitrogen and sulfur compounds using a modified MARGA 2S: Assessment and control of data quality

    EPA Science Inventory

    Improved measurement methods are needed to characterize dry deposition of sulfur and nitrogen compounds to assess ecosystem exposure to nutrients and acidifying compounds and to develop atmospheric deposition budgets in support of critical loads assessments. The purpose of this ...

  4. Stability of Teacher Value-Added Rankings across Measurement Model and Scaling Conditions

    ERIC Educational Resources Information Center

    Hawley, Leslie R.; Bovaird, James A.; Wu, ChaoRong

    2017-01-01

    Value-added assessment methods have been criticized by researchers and policy makers for a number of reasons. One issue includes the sensitivity of model results across different outcome measures. This study examined the utility of incorporating multivariate latent variable approaches within a traditional value-added framework. We evaluated the…

  5. Construction and Validation of an Instrument to Measure Environmental Orientations in a Diverse Group of Children

    ERIC Educational Resources Information Center

    Larson, Lincoln R.; Green, Gary T.; Castleberry, Steven B.

    2011-01-01

    An understanding of children's environmental orientations is of critical importance as opportunities for authentic contact with nature diminish. Current instruments for measuring children's environmental attitudes are complex, and few have been tested across diverse audiences. This study employed a mixed-methods approach that included pilot tests,…

  6. State-of-the-Art Methods for Skeletal Muscle Glycogen Analysis in Athletes—The Need for Novel Non-Invasive Techniques

    PubMed Central

    Greene, Jacob; Louis, Julien; Korostynska, Olga; Mason, Alex

    2017-01-01

    Muscle glycogen levels have a profound impact on an athlete’s sporting performance, thus measurement is vital. Carbohydrate manipulation is a fundamental component in an athlete’s lifestyle and is a critical part of elite performance, since it can provide necessary training adaptations. This paper provides a critical review of the current invasive and non-invasive methods for measuring skeletal muscle glycogen levels. These include the gold standard muscle biopsy, histochemical analysis, magnetic resonance spectroscopy, and musculoskeletal high frequency ultrasound, as well as pursuing future application of electromagnetic sensors in the pursuit of portable non-invasive quantification of muscle glycogen. This paper will be of interest to researchers who wish to understand the current and most appropriate techniques in measuring skeletal muscle glycogen. This will have applications both in the lab and in the field by improving the accuracy of research protocols and following the physiological adaptations to exercise. PMID:28241495

  7. Clustering biomolecular complexes by residue contacts similarity.

    PubMed

    Rodrigues, João P G L M; Trellet, Mikaël; Schmitz, Christophe; Kastritis, Panagiotis; Karaca, Ezgi; Melquiond, Adrien S J; Bonvin, Alexandre M J J

    2012-07-01

    Inaccuracies in computational molecular modeling methods are often counterweighed by brute-force generation of a plethora of putative solutions. These are then typically sieved via structural clustering based on similarity measures such as the root mean square deviation (RMSD) of atomic positions. Albeit widely used, these measures suffer from several theoretical and technical limitations (e.g., choice of regions for fitting) that impair their application in multicomponent systems (N > 2), large-scale studies (e.g., interactomes), and other time-critical scenarios. We present here a simple similarity measure for structural clustering based on atomic contacts--the fraction of common contacts--and compare it with the most used similarity measure of the protein docking community--interface backbone RMSD. We show that this method produces very compact clusters in remarkably short time when applied to a collection of binary and multicomponent protein-protein and protein-DNA complexes. Furthermore, it allows easy clustering of similar conformations of multicomponent symmetrical assemblies in which chain permutations can occur. Simple contact-based metrics should be applicable to other structural biology clustering problems, in particular for time-critical or large-scale endeavors. Copyright © 2012 Wiley Periodicals, Inc.

  8. Methods of measuring Protein Disulfide Isomerase activity: a critical overview

    NASA Astrophysics Data System (ADS)

    Watanabe, Monica; Laurindo, Francisco; Fernandes, Denise

    2014-09-01

    Protein disulfide isomerase is an essential redox chaperone from the endoplasmic reticulum (ER) and is responsible for correct disulfide bond formation in nascent proteins. PDI is also found in other cellular locations in the cell, particularly the cell surface. Overall, PDI contributes to ER and global cell redox homeostasis and signaling. The knowledge about PDI structure and function progressed substantially based on in vitro studies using recombinant PDI and chimeric proteins. In these experimental scenarios, PDI reductase and chaperone activities are readily approachable. In contrast, assays to measure PDI isomerase activity, the hallmark of PDI family, are more complex. Assessment of PDI roles in cells and tissues mainly relies on gain- or loss-of-function studies. However, there is limited information regarding correlation of experimental readouts with the distinct types of PDI activities. In this mini-review, we evaluate the main methods described for measuring the different kinds of PDI activity: thiol reductase, thiol oxidase, thiol isomerase and chaperone. We emphasize the need to use appropriate controls and the role of critical interferents (e.g., detergent, presence of reducing agents). We also discuss the translation of results from in vitro studies with purified recombinant PDI to cellular and tissue samples, with critical comments on the interpretation of results.

  9. An Examination of Postsecondary Faculty and the Extent of Critical Reading Taught in 100-Level Introductory Biology and American History Courses in Publicly Funded Two-Year and Four-Year Pennsylvania Institutions

    NASA Astrophysics Data System (ADS)

    Sand, Dianna

    This research examined the responses of postsecondary faculty on a critical reading inventory. The research is quantitative, non-experimental, and incorporates a multiple regression model in the analyses. Three research questions guided this study: (1) By institution type: To what degree does institution type predict the extent to which postsecondary faculty teach critical reading as measured by the Reading Goals Inventory (Jones, 1996)? (2) By faculty status: To what degree does faculty status predict the extent to which postsecondary faculty teach critical reading as measured by the Reading Goals Inventory (Jones, 1996)? (3) By disciplinary area: To what degree does disciplinary area predict the extent to which postsecondary faculty teach critical reading as measured by the Reading Goals Inventory (Jones, 1996)? Faculty from 28 Pennsylvania postsecondary institutions participated in this study. Faculty respondents taught 100-level introductory biology or American history courses either part-time or full-time at Pennsylvania community colleges or Pennsylvania State System of Higher Education (PASSHE) universities. Fifty-four faculty respondents completed the Reading Goals Inventory (Jones, 1996). The researcher conducted multiple regression analyses using a hierarchical method. Predictor variables included Institution Type, Faculty Status, and Disciplinary Area; criterion or outcome variables included seven sub-scales of the critical reading inventory. In this study, Institution Type and Faculty Status were not significant predictors. Disciplinary Area was a consistent significant predictor of the amount of critical reading taught as measured in the Interpretation, Analysis, Evaluation, and Reflection sub-scales of the Reading Goals Inventory (Jones, 1996).

  10. Comparison of adaptive critic-based and classical wide-area controllers for power systems.

    PubMed

    Ray, Swakshar; Venayagamoorthy, Ganesh Kumar; Chaudhuri, Balarko; Majumder, Rajat

    2008-08-01

    An adaptive critic design (ACD)-based damping controller is developed for a thyristor-controlled series capacitor (TCSC) installed in a power system with multiple poorly damped interarea modes. The performance of this ACD computational intelligence-based method is compared with two classical techniques, which are observer-based state-feedback (SF) control and linear matrix inequality LMI-H(infinity) robust control. Remote measurements are used as feedback signals to the wide-area damping controller for modulating the compensation of the TCSC. The classical methods use a linearized model of the system whereas the ACD method is purely measurement-based, leading to a nonlinear controller with fixed parameters. A comparative analysis of the controllers' performances is carried out under different disturbance scenarios. The ACD-based design has shown promising performance with very little knowledge of the system compared to classical model-based controllers. This paper also discusses the advantages and disadvantages of ACDs, SF, and LMI-H(infinity).

  11. Fluorescence microplate readers as an alternative to flow injection analysis for determination of wort beta-glucan

    USDA-ARS?s Scientific Manuscript database

    Wort beta-glucan concentration is a critical malting quality parameter used to identify and avoid potential brewhouse filtration problems. ASBC method Wort-18 is widely used in malt analysis laboratories and brewhouses to measure wort beta-glucan levels. However, the chemistry underlying the method...

  12. Understanding Student Stress and Coping in Elementary School: A Mixed-Method, Longitudinal Study

    ERIC Educational Resources Information Center

    Sotardi, Valerie A.

    2016-01-01

    This mixed-method, longitudinal study examined daily school stress and coping strategies of elementary schoolchildren in the United States. Students (n = 65) between the ages of 7 and 11 years reported daily school stress measures for 8 weeks and completed individual stress and coping interviews. Results highlight critical relations between…

  13. Textbook Citations as a Measure of Journal Influence on International Business Education

    ERIC Educational Resources Information Center

    Urbancic, Frank R.

    2006-01-01

    Previously published rankings of journals in relation to international business research are based on a survey method or a journal-based citation method wherein functional discipline journals are excluded from consideration. The narrow focus of these studies has generated criticism for perpetuating an international business silo perspective. In…

  14. A critical analysis of methods for rapid and nondestructive determination of wood density in standing trees

    Treesearch

    Shan Gao; Xiping Wang; Michael C. Wiemann; Brian K. Brashaw; Robert J. Ross; Lihai Wang

    2017-01-01

    Key message Field methods for rapid determination of wood density in trees have evolved from increment borer, torsiometer, Pilodyn, and nail withdrawal into sophisticated electronic tools of resistance drilling measurement. A partial resistance drilling approach coupled with knowledge of internal tree density distribution may...

  15. Determination of bromine in selected polymer materials by a wavelength-dispersive X-ray fluorescence spectrometric method - Critical thickness problem and solutions

    NASA Astrophysics Data System (ADS)

    Gorewoda, Tadeusz; Mzyk, Zofia; Anyszkiewicz, Jacek; Charasińska, Jadwiga

    2015-04-01

    The purpose of this study was to develop an accurate method for the determination of bromine in polymer materials using X-ray fluorescence spectrometry when the thickness of the sample is less than the bromine critical thickness (tc) value. This is particularly important for analyzing compliance with the Restriction of Hazardous Substances Directive. Mathematically and experimentally estimated tc values in polyethylene and cellulose matrixes were up to several millimeters. Four methods were developed to obtain an accurate result. These methods include the addition of an element with a high mass absorption coefficient, the measurement of the total bromine contained in a defined volume of the sample, the exploitation of tube-Rayleigh line intensities and using the Br-Lβ line.

  16. M-OSCE as a method to measure dental hygiene students' critical thinking: a pilot study.

    PubMed

    McComas, Martha J; Wright, Rebecca A; Mann, Nancy K; Cooper, Mary D; Jacks, Mary E

    2013-04-01

    Educators in all academic disciplines have been encouraged to utilize assessment strategies to evaluate students' critical thinking. The purpose of this study was to assess the viability of the modified objective structured clinical examination (m-OSCE) to evaluate critical thinking in dental hygiene education. This evaluation utilized a convenience sample of senior dental hygiene students. Students participated in the m-OSCE in which portions of a patient case were revealed at four stations. The exam consisted of multiple-choice questions intended to measure students' ability to utilize critical thinking skills. Additionally, there was one fill-in-the-blank question and a treatment plan that was completed at the fifth station. The results of this study revealed that the m-OSCE did not reliably measure dental hygiene students' critical thinking. Statistical analysis found no satisfactory reliability within the multiple-choice questions and moderately reliable results within the treatment planning portion of the examination. In addition, the item analysis found gaps in students' abilities to transfer clinical evidence/data to basic biomedical knowledge as demonstrated through the multiple-choice questioning results. This outcome warrants further investigation of the utility of the m-OSCE, with a focus on modifications to the evaluation questions, grading rubric, and patient case.

  17. An Integrative Review of the Concealed Connection: Nurse Educators' Critical Thinking.

    PubMed

    Raymond, Christy; Profetto-McGrath, Joanne; Myrick, Florence; Strean, William B

    2017-11-01

    The role of nurse educators in the development of students' critical thinking has been overlooked despite the emphasized need for effective teaching methods. An integrative review was performed to examine both quantitative and qualitative research published from 2000 to 2015 related to nurse educators' critical thinking. Many barriers and facilitators existing on individual, interpersonal, and contextual levels affected nurse educators' critical thinking. Various tools have been used to measure nurse educators' critical thinking. This review also highlighted the continued lack of a consensus definition of critical thinking and the limited presence of conceptual models to guide the use of critical thinking in nursing education. Continued examination of nurse educators' critical thinking is needed, given the limited number of studies that have been completed. Much needs to be explored further, including conceptualizations of critical thinking and confirmation of emerging themes identified in this review. [J Nurs Educ. 2017;56(11):648-654.]. © 2017 Raymond, Profetto-McGrath, Myrick, et al.

  18. Performance of Predictive Equations Specifically Developed to Estimate Resting Energy Expenditure in Ventilated Critically Ill Children.

    PubMed

    Jotterand Chaparro, Corinne; Taffé, Patrick; Moullet, Clémence; Laure Depeyre, Jocelyne; Longchamp, David; Perez, Marie-Hélène; Cotting, Jacques

    2017-05-01

    To determine, based on indirect calorimetry measurements, the biases of predictive equations specifically developed recently for estimating resting energy expenditure (REE) in ventilated critically ill children, or developed for healthy populations but used in critically ill children. A secondary analysis study was performed using our data on REE measured in a previous prospective study on protein and energy needs in pediatric intensive care unit. We included 75 ventilated critically ill children (median age, 21 months) in whom 407 indirect calorimetry measurements were performed. Fifteen predictive equations were used to estimate REE: the equations of White, Meyer, Mehta, Schofield, Henry, the World Health Organization, Fleisch, and Harris-Benedict and the tables of Talbot. Their differential and proportional biases (with 95% CIs) were computed and the bias plotted in graphs. The Bland-Altman method was also used. Most equations underestimated and overestimated REE between 200 and 1000 kcal/day. The equations of Mehta, Schofield, and Henry and the tables of Talbot had a bias ≤10%, but the 95% CI was large and contained values by far beyond ±10% for low REE values. Other specific equations for critically ill children had even wider biases. In ventilated critically ill children, none of the predictive equations tested met the performance criteria for the entire range of REE between 200 and 1000 kcal/day. Even the equations with the smallest bias may entail a risk of underfeeding or overfeeding, especially in the youngest children. Indirect calorimetry measurement must be preferred. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. A critical comparison of electrical methods for measuring spin-orbit torques

    NASA Astrophysics Data System (ADS)

    Zhang, Xuanzi; Hung, Yu-Ming; Rehm, Laura; Kent, Andrew D.

    Direct (DC) and alternating current (AC) transport measurements of spin-orbit torques (SOTs) in heavy metal-ferromagnet heterostructure with perpendicular magnetic anisotropy have been proposed and demonstrated. A DC method measures the change of perpendicular magnetization component while an AC method probes the first and second harmonic magnetization oscillation in responses to an AC current (~1 kHz). Here we conduct both types of measurements on β-Ta/CoFeB/MgO in the form of patterned Hall bars (20 μm linewidth) and compare the results. Experiments results are qualitatively in agreement with a macro spin model including Slonzewski-like and a field-like SOTs. However, the effective field from the ac method is larger than that obtained from the DC method. We discuss the possible origins of the discrepancy and its implications for quantitatively determining SOTs. Research supported by the SRC-INDEX program, NSF-DMR-1309202 and NYU-DURF award.

  20. Probing the critical zone using passive- and active-source estimates of subsurface shear-wave velocities

    NASA Astrophysics Data System (ADS)

    Callahan, R. P.; Taylor, N. J.; Pasquet, S.; Dueker, K. G.; Riebe, C. S.; Holbrook, W. S.

    2016-12-01

    Geophysical imaging is rapidly becoming popular for quantifying subsurface critical zone (CZ) architecture. However, a diverse array of measurements and measurement techniques are available, raising the question of which are appropriate for specific study goals. Here we compare two techniques for measuring S-wave velocities (Vs) in the near surface. The first approach quantifies Vs in three dimensions using a passive source and an iterative residual least-squares tomographic inversion. The second approach uses a more traditional active-source seismic survey to quantify Vs in two dimensions via a Monte Carlo surface-wave dispersion inversion. Our analysis focuses on three 0.01 km2 study plots on weathered granitic bedrock in the Southern Sierra Critical Zone Observatory. Preliminary results indicate that depth-averaged velocities from the two methods agree over the scales of resolution of the techniques. While the passive- and active-source techniques both quantify Vs, each method has distinct advantages and disadvantages during data acquisition and analysis. The passive-source method has the advantage of generating a three dimensional distribution of subsurface Vs structure across a broad area. Because this method relies on the ambient seismic field as a source, which varies unpredictably across space and time, data quality and depth of investigation are outside the control of the user. Meanwhile, traditional active-source surveys can be designed around a desired depth of investigation. However, they only generate a two dimensional image of Vs structure. Whereas traditional active-source surveys can be inverted quickly on a personal computer in the field, passive source surveys require significantly more computations, and are best conducted in a high-performance computing environment. We use data from our study sites to compare these methods across different scales and to explore how these methods can be used to better understand subsurface CZ architecture.

  1. Experimental aspects of buoyancy correction in measuring reliable high-pressure excess adsorption isotherms using the gravimetric method

    NASA Astrophysics Data System (ADS)

    Nguyen, Huong Giang T.; Horn, Jarod C.; Thommes, Matthias; van Zee, Roger D.; Espinal, Laura

    2017-12-01

    Addressing reproducibility issues in adsorption measurements is critical to accelerating the path to discovery of new industrial adsorbents and to understanding adsorption processes. A National Institute of Standards and Technology Reference Material, RM 8852 (ammonium ZSM-5 zeolite), and two gravimetric instruments with asymmetric two-beam balances were used to measure high-pressure adsorption isotherms. This work demonstrates how common approaches to buoyancy correction, a key factor in obtaining the mass change due to surface excess gas uptake from the apparent mass change, can impact the adsorption isotherm data. Three different approaches to buoyancy correction were investigated and applied to the subcritical CO2 and supercritical N2 adsorption isotherms at 293 K. It was observed that measuring a collective volume for all balance components for the buoyancy correction (helium method) introduces an inherent bias in temperature partition when there is a temperature gradient (i.e. analysis temperature is not equal to instrument air bath temperature). We demonstrate that a blank subtraction is effective in mitigating the biases associated with temperature partitioning, instrument calibration, and the determined volumes of the balance components. In general, the manual and subtraction methods allow for better treatment of the temperature gradient during buoyancy correction. From the study, best practices specific to asymmetric two-beam balances and more general recommendations for measuring isotherms far from critical temperatures using gravimetric instruments are offered.

  2. Experimental aspects of buoyancy correction in measuring reliable highpressure excess adsorption isotherms using the gravimetric method.

    PubMed

    Nguyen, Huong Giang T; Horn, Jarod C; Thommes, Matthias; van Zee, Roger D; Espinal, Laura

    2017-12-01

    Addressing reproducibility issues in adsorption measurements is critical to accelerating the path to discovery of new industrial adsorbents and to understanding adsorption processes. A National Institute of Standards and Technology Reference Material, RM 8852 (ammonium ZSM-5 zeolite), and two gravimetric instruments with asymmetric two-beam balances were used to measure high-pressure adsorption isotherms. This work demonstrates how common approaches to buoyancy correction, a key factor in obtaining the mass change due to surface excess gas uptake from the apparent mass change, can impact the adsorption isotherm data. Three different approaches to buoyancy correction were investigated and applied to the subcritical CO 2 and supercritical N 2 adsorption isotherms at 293 K. It was observed that measuring a collective volume for all balance components for the buoyancy correction (helium method) introduces an inherent bias in temperature partition when there is a temperature gradient (i.e. analysis temperature is not equal to instrument air bath temperature). We demonstrate that a blank subtraction is effective in mitigating the biases associated with temperature partitioning, instrument calibration, and the determined volumes of the balance components. In general, the manual and subtraction methods allow for better treatment of the temperature gradient during buoyancy correction. From the study, best practices specific to asymmetric two-beam balances and more general recommendations for measuring isotherms far from critical temperatures using gravimetric instruments are offered.

  3. Navigational Traffic Conflict Technique: A Proactive Approach to Quantitative Measurement of Collision Risks in Port Waters

    NASA Astrophysics Data System (ADS)

    Debnath, Ashim Kumar; Chin, Hoong Chor

    Navigational safety analysis relying on collision statistics is often hampered because of the low number of observations. A promising alternative approach that overcomes this problem is proposed in this paper. By analyzing critical vessel interactions this approach proactively measures collision risk in port waters. The proposed method is illustrated for quantitative measurement of collision risks in Singapore port fairways, and validated by examining correlations between the measured risks with those perceived by pilots. This method is an ethically appealing alternative to the collision-based analysis for fast, reliable and effective safety assessment, thus possessing great potential for managing collision risks in port waters.

  4. Trends in measurement models and methods in understanding occupational health psychology.

    PubMed

    Tetrick, Lois E

    2017-07-01

    Measurement of occupational health psychology constructs is the cornerstone to developing our understanding of occupational health and safety. It also is critical in the design, evaluation, and implementation of interventions to improve employees and organizations well-being. The purpose of this article is a brief review of the current state of measurement theory and practice in occupational health psychology. Also included are a discussion of development of newer measurement models and methods, which are in use in other disciplines of psychology, but have not been incorporated into the occupational health psychology. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  5. Development of Measurement Methods for Detection of Special Nuclear Materials using D-D Pulsed Neutron Source

    NASA Astrophysics Data System (ADS)

    Misawa, Tsuyoshi; Takahashi, Yoshiyuki; Yagi, Takahiro; Pyeon, Cheol Ho; Kimura, Masaharu; Masuda, Kai; Ohgaki, Hideaki

    2015-10-01

    For detection of hidden special nuclear materials (SNMs), we have developed an active neutron-based interrogation system combined with a D-D fusion pulsed neutron source and a neutron detection system. In the detection scheme, we have adopted new measurement techniques simultaneously; neutron noise analysis and neutron energy spectrum analysis. The validity of neutron noise analysis method has been experimentally studied in the Kyoto University Critical Assembly (KUCA), and was applied to a cargo container inspection system by simulation.

  6. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    PubMed

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  7. Radionuclide evaluation of left ventricular function with nonimaging probes.

    PubMed

    Wexler, J P; Blaufox, M D

    1979-10-01

    Portable nonimaging probes have been developed that can evaluate left ventricular function using radionuclide techniques. Two modes of data acquisition are possible with these probe systems, first-pass and gated. Precordial radiocardiograms obtained after a bolus injection can be used to determine cardiac output, pulmonary transit time, pulmonary blood volume, left ventricle ejection fraction, and left-to-right shunts. Gated techniques can be used to determine left ventricular ejection fraction and sytolic time intervals. Probe-determined indices of left ventricular function agree excellently with comparable measurements determined by conventional camera-computer methods as well as by invasive techniques. These have begun to be used in a preliminary manner in a variety of clinical problems associated with left ventricular dysfunction. This review discusses the types of probe systems available, the methods used in positioning them, and details the specifics of their data acquisition and processing capacity. The major criticisms of probe methods are that they are nonimaging and that they measure global rather than regional left ventricular function. In spite of these criticisms, probe systems, because of their portability, high sensitivity, and relatively low cost are useful supplements to conventional camera-computer systems for the measurement of parameters of left ventricular performance using radionuclide techniques.

  8. Joint Research on Scatterometry and AFM Wafer Metrology

    NASA Astrophysics Data System (ADS)

    Bodermann, Bernd; Buhr, Egbert; Danzebrink, Hans-Ulrich; Bär, Markus; Scholze, Frank; Krumrey, Michael; Wurm, Matthias; Klapetek, Petr; Hansen, Poul-Erik; Korpelainen, Virpi; van Veghel, Marijn; Yacoot, Andrew; Siitonen, Samuli; El Gawhary, Omar; Burger, Sven; Saastamoinen, Toni

    2011-11-01

    Supported by the European Commission and EURAMET, a consortium of 10 participants from national metrology institutes, universities and companies has started a joint research project with the aim of overcoming current challenges in optical scatterometry for traceable linewidth metrology. Both experimental and modelling methods will be enhanced and different methods will be compared with each other and with specially adapted atomic force microscopy (AFM) and scanning electron microscopy (SEM) measurement systems in measurement comparisons. Additionally novel methods for sophisticated data analysis will be developed and investigated to reach significant reductions of the measurement uncertainties in critical dimension (CD) metrology. One final goal will be the realisation of a wafer based reference standard material for calibration of scatterometers.

  9. Improving Control System Cyber-State Awareness using Known Secure Sensor Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ondrej Linda; Milos Manic; Miles McQueen

    Abstract—This paper presents design and simulation of a low cost and low false alarm rate method for improved cyber-state awareness of critical control systems - the Known Secure Sensor Measurements (KSSM) method. The KSSM concept relies on physical measurements to detect malicious falsification of the control systems state. The KSSM method can be incrementally integrated with already installed control systems for enhanced resilience. This paper reviews the previously developed theoretical KSSM concept and then describes a simulation of the KSSM system. A simulated control system network is integrated with the KSSM components. The effectiveness of detection of various intrusion scenariosmore » is demonstrated on several control system network topologies.« less

  10. Likert scales, levels of measurement and the "laws" of statistics.

    PubMed

    Norman, Geoff

    2010-12-01

    Reviewers of research reports frequently criticize the choice of statistical methods. While some of these criticisms are well-founded, frequently the use of various parametric methods such as analysis of variance, regression, correlation are faulted because: (a) the sample size is too small, (b) the data may not be normally distributed, or (c) The data are from Likert scales, which are ordinal, so parametric statistics cannot be used. In this paper, I dissect these arguments, and show that many studies, dating back to the 1930s consistently show that parametric statistics are robust with respect to violations of these assumptions. Hence, challenges like those above are unfounded, and parametric methods can be utilized without concern for "getting the wrong answer".

  11. Using Machine Learning to Predict MCNP Bias

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Grechanuk, Pavel Aleksandrovi

    For many real-world applications in radiation transport where simulations are compared to experimental measurements, like in nuclear criticality safety, the bias (simulated - experimental k eff) in the calculation is an extremely important quantity used for code validation. The objective of this project is to accurately predict the bias of MCNP6 [1] criticality calculations using machine learning (ML) algorithms, with the intention of creating a tool that can complement the current nuclear criticality safety methods. In the latest release of MCNP6, the Whisper tool is available for criticality safety analysts and includes a large catalogue of experimental benchmarks, sensitivity profiles,more » and nuclear data covariance matrices. This data, coming from 1100+ benchmark cases, is used in this study of ML algorithms for criticality safety bias predictions.« less

  12. Enhanced superconducting transition temperature in electroplated rhenium

    NASA Astrophysics Data System (ADS)

    Pappas, D. P.; David, D. E.; Lake, R. E.; Bal, M.; Goldfarb, R. B.; Hite, D. A.; Kim, E.; Ku, H.-S.; Long, J. L.; McRae, C. R. H.; Pappas, L. D.; Roshko, A.; Wen, J. G.; Plourde, B. L. T.; Arslan, I.; Wu, X.

    2018-04-01

    We show that electroplated Re films in multilayers with noble metals such as Cu, Au, and Pd have an enhanced superconducting critical temperature relative to previous methods of preparing Re. The dc resistance and magnetic susceptibility indicate a critical temperature of approximately 6 K. The magnetic response as a function of field at 1.8 K demonstrates type-II superconductivity, with an upper critical field on the order of 2.5 T. Critical current densities greater than 107 A/m2 were measured above liquid-helium temperature. Low-loss at radio frequency was obtained below the critical temperature for multilayers deposited onto resonators made with Cu traces on commercial circuit boards. These electroplated superconducting films can be integrated into a wide range of standard components for low-temperature electronics.

  13. Assessment of hydration status using bioelectrical impedance vector analysis in critical patients with acute kidney injury.

    PubMed

    Hise, Ana Cláudia da Rosa; Gonzalez, Maria Cristina

    2018-04-01

    The state of hyperhydration in critically ill patients with acute kidney injury (AKI) is associated with increased mortality. Bioelectrical impedance vector analysis (BIVA) appears to be a viable method to access the fluid status of critical patients but has never been evaluated in critical patients with AKI. The objective of this study is to evaluate the hydration status measured using BIVA in critical patients under intensive care at the time of AKI diagnosis and to correlate this measurement with mortality. We assessed the fluid status measured using BIVA in 224 critical patients at the time of AKI diagnosis and correlated it with mortality. To interpret the results, BIVA Software 2002 was used to plot the data from the patients studied on the 95% confidence ellipses of the RX c plane for comparisons between groups (non-survivors, survivors). Variables such as mechanical ventilation, vasoactive drug, and sepsis, among others, were collected. The impedance vector analysis conducted using BIVA Software 2002 indicated changes in the body compositions of patients according to the 95% confidence ellipse between the vectors R/H and X c /H of the group of survivors and the group of deceased patients. Hotelling's test (T 2  = 21.2) and the F test (F = 10.6) revealed significant differences (p < 0.001) between the two groups. These results demonstrate that patients who died presented with a greater hydration volume at the time of AKI diagnosis compared with those who survived. In addition to the hydration status measured using BIVA, the following were also correlated with death: diagnosis at hospitalization, APACHE II score, length of hospital stay, RIFLE score, maximum organ failure, sepsis type, hemoglobin, and AF. The fluid status assessment measured using BIVA significantly demonstrated the difference in hydration between survivors and non-survivors among critically ill patients with AKI. Copyright © 2017 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

  14. Comparing Science Virtual and Paper-Based Test to Measure Students’ Critical Thinking based on VAK Learning Style Model

    NASA Astrophysics Data System (ADS)

    Rosyidah, T. H.; Firman, H.; Rusyati, L.

    2017-02-01

    This research was comparing virtual and paper-based test to measure students’ critical thinking based on VAK (Visual-Auditory-Kynesthetic) learning style model. Quasi experiment method with one group post-test only design is applied in this research in order to analyze the data. There was 40 eight grade students at one of public junior high school in Bandung becoming the sample in this research. The quantitative data was obtained through 26 questions about living thing and environment sustainability which is constructed based on the eight elements of critical thinking and be provided in the form of virtual and paper-based test. Based on analysis of the result, it is shown that within visual, auditory, and kinesthetic were not significantly difference in virtual and paper-based test. Besides, all result was supported by quistionnaire about students’ respond on virtual test which shows 3.47 in the scale of 4. Means that student showed positive respond in all aspet measured, which are interest, impression, and expectation.

  15. In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care.

    PubMed

    Ciaffoni, Luca; O'Neill, David P; Couper, John H; Ritchie, Grant A D; Hancock, Gus; Robbins, Peter A

    2016-08-01

    There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible.

  16. In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care

    PubMed Central

    Ciaffoni, Luca; O’Neill, David P.; Couper, John H.; Ritchie, Grant A. D.; Hancock, Gus; Robbins, Peter A.

    2016-01-01

    There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accurate alignment of gas concentrations with respiratory flow, makes possible the determination of O2 consumption by direct integration over time of the product of O2 concentration and flow. The precision is illustrated by integrating the balance gas (N2 plus Ar) flow and showing that this exchange was near zero. Measured O2 consumption changed by <5% between air and O2 breathing. Clinical capability was illustrated by recording O2 consumption during an aortic aneurysm repair. This device now makes easy, accurate, and noninvasive measurement of O2 consumption for intubated patients in critical care possible. PMID:27532048

  17. Comparison of two methods for cardiac output measurement in critically ill patients.

    PubMed

    Saraceni, E; Rossi, S; Persona, P; Dan, M; Rizzi, S; Meroni, M; Ori, C

    2011-05-01

    The aim of recent haemodynamic monitoring has been to obtain continuous and reliable measures of cardiac output (CO) and indices of preload responsiveness. Many of these methods are based on the arterial pressure waveform analysis. The aim of our study was to assess the accuracy of CO measurements obtained by FloTrac/Vigileo, software version 1.07 and the new version 1.10 (Edwards Lifesciences LLC, Irvine, CA, USA), compared with CO measurements obtained by bolus thermodilution by pulmonary artery catheterization (PAC) in the intensive care setting. In 21 critically ill patients (enrolled in two University Hospitals), requiring invasive haemodynamic monitoring, PAC and FloTrac/Vigileo transducers connected to the arterial pressure line were placed. Simultaneous measurements of CO by two methods (FloTrac/Vigileo and thermodilution) were obtained three times a day for 3 consecutive days, when possible. The level of concordance between the two methods was assessed by the procedure suggested by Bland and Altman. One hundred and forty-one pairs of measurements (provided by thermodilution and by both 1.07 and 1.10 FloTrac/Vigileo versions) were obtained in 21 patients (seven of them were trauma patients) with a mean (sd) age of 59 (16) yr. The Pearson product moment coefficient was 0.62 (P<0.001). The bias was -0.18 litre min(-1). The limits of agreement were 4.54 and -4.90 litre min(-1), respectively. Our data show a poor level of concordance between measures provided by the two methods. We found an underestimation of CO values measured with the 1.07 software version of FloTrac for supranormal values of CO. The new software (1.10) has been improved in order to correct this bias; however, its reliability is still poor. On the basis of our data, we can therefore conclude that both software versions of FloTrac/Vigileo did not still provide reliable estimation of CO in our intensive care unit setting.

  18. Cyber Vulnerabilities Within Critical Infrastructure: The Flaws of Industrial Control Systems in the Oil and Gas Industry

    NASA Astrophysics Data System (ADS)

    Alpi, Danielle Marie

    The 16 sectors of critical infrastructure in the US are susceptible to cyber-attacks. Potential attacks come from internal and external threats. These attacks target the industrial control systems (ICS) of companies within critical infrastructure. Weakness in the energy sector's ICS, specifically the oil and gas industry, can result in economic and ecological disaster. The purpose of this study was to establish means for oil companies to identify and stop cyber-attacks specifically APT threats. This research reviewed current cyber vulnerabilities and ways in which a cyber-attack may be deterred. This research found that there are insecure devices within ICS that are not regularly updated. Therefore, security issues have amassed. Safety procedures and training thereof are often neglected. Jurisdiction is unclear in regard to critical infrastructure. The recommendations this research offers are further examination of information sharing methods, development of analytic platforms, and better methods for the implementation of defense-in-depth security measures.

  19. Software Safety Risk in Legacy Safety-Critical Computer Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice; Baggs, Rhoda

    2007-01-01

    Safety-critical computer systems must be engineered to meet system and software safety requirements. For legacy safety-critical computer systems, software safety requirements may not have been formally specified during development. When process-oriented software safety requirements are levied on a legacy system after the fact, where software development artifacts don't exist or are incomplete, the question becomes 'how can this be done?' The risks associated with only meeting certain software safety requirements in a legacy safety-critical computer system must be addressed should such systems be selected as candidates for reuse. This paper proposes a method for ascertaining formally, a software safety risk assessment, that provides measurements for software safety for legacy systems which may or may not have a suite of software engineering documentation that is now normally required. It relies upon the NASA Software Safety Standard, risk assessment methods based upon the Taxonomy-Based Questionnaire, and the application of reverse engineering CASE tools to produce original design documents for legacy systems.

  20. Comparison of measured versus predicted energy requirements in critically ill cancer patients.

    PubMed

    Pirat, Arash; Tucker, Anne M; Taylor, Kim A; Jinnah, Rashida; Finch, Clarence G; Canada, Todd D; Nates, Joseph L

    2009-04-01

    Accurate determination of caloric requirements is essential to avoid feeding-associated complications in critically ill patients. In critically ill cancer patients we compared the measured and estimated resting energy expenditures. All patients admitted to the oncology intensive care unit between March 2004 and July 2005 were considered for inclusion. For those patients enrolled (n = 34) we measured resting energy expenditure via indirect calorimetry, and estimated resting energy expenditure in 2 ways: clinically estimated resting energy expenditure; and the Harris-Benedict basal energy expenditure equation. Clinically estimated resting energy expenditure was associated with underfeeding, appropriate feeding, and overfeeding in approximately 15%, 15%, and 71% of the patients, respectively. The Harris-Benedict basal energy expenditure was associated with underfeeding, appropriate feeding, and overfeeding in approximately 29%, 41%, and 29% of the patients, respectively. The mean measured resting energy expenditure (1,623 +/- 384 kcal/d) was similar to the mean Harris-Benedict basal energy expenditure without the addition of stress or activity factors (1,613 +/- 382 kcal/d, P = .87), and both were significantly lower than the mean clinically estimated resting energy expenditure (1,862 +/- 330 kcal/d, P < or = .003 for both). There was a significant correlation only between mean measured resting energy expenditure and mean Harris-Benedict basal energy expenditure (P < .001), but the correlation coefficient between those values was low (r = 0.587). Underfeeding and overfeeding were common in our critically ill cancer patients when resting energy expenditure was estimated rather than measured. Indirect calorimetry is the method of choice for determining caloric need in critically ill cancer patients, but if indirect calorimetry is not available or feasible, the Harris-Benedict equation without added stress and activity factors is more accurate than the clinically estimated resting energy expenditure.

  1. Quantifying Complexity in Quantum Phase Transitions via Mutual Information Complex Networks

    NASA Astrophysics Data System (ADS)

    Valdez, Marc Andrew; Jaschke, Daniel; Vargas, David L.; Carr, Lincoln D.

    2017-12-01

    We quantify the emergent complexity of quantum states near quantum critical points on regular 1D lattices, via complex network measures based on quantum mutual information as the adjacency matrix, in direct analogy to quantifying the complexity of electroencephalogram or functional magnetic resonance imaging measurements of the brain. Using matrix product state methods, we show that network density, clustering, disparity, and Pearson's correlation obtain the critical point for both quantum Ising and Bose-Hubbard models to a high degree of accuracy in finite-size scaling for three classes of quantum phase transitions, Z2, mean field superfluid to Mott insulator, and a Berzinskii-Kosterlitz-Thouless crossover.

  2. New method for measuring the laser-induced damage threshold of optical thin film

    NASA Astrophysics Data System (ADS)

    Su, Jun-hong; Wang, Hong; Xi, Ying-xue

    2012-10-01

    The laser-induced damage threshold (LIDT) of thin film means that the thin film can withstand a maximum intensity of laser radiation. The film will be damaged when the irradiation under high laser intensity is greater than the value of LIDT. In this paper, an experimental platform with measurement operator interfaces and control procedures in the VB circumstance is built according to ISO11254-1. In order to obtain more accurate results than that with manual measurement, in the software system, a hardware device can be controlled by control widget on the operator interfaces. According to the sample characteristic, critical parameters of the LIDT measurement system such as spot diameter, damage threshold region, and critical damage pixel number are set up on the man-machine conversation interface, which could realize intelligent measurements of the LIDT. According to experimental data, the LIDT is obtained by fitting damage curve automatically.

  3. Simultaneous imaging/reflectivity measurements to assess diagnostic mirror cleaning.

    PubMed

    Skinner, C H; Gentile, C A; Doerner, R

    2012-10-01

    Practical methods to clean ITER's diagnostic mirrors and restore reflectivity will be critical to ITER's plasma operations. We describe a technique to assess the efficacy of mirror cleaning techniques and detect any damage to the mirror surface. The method combines microscopic imaging and reflectivity measurements in the red, green, and blue spectral regions and at selected wavelengths. The method has been applied to laser cleaning of single crystal molybdenum mirrors coated with either carbon or beryllium films 150-420 nm thick. It is suitable for hazardous materials such as beryllium as the mirrors remain sealed in a vacuum chamber.

  4. Nuclear Forensics: Measurements of Uranium Oxides Using Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS)

    DTIC Science & Technology

    2010-03-01

    Isotope Ratio Analysis of Actinides , Fission Products, and Geolocators by High- efficiency Multi-collector Thermal Ionization Mass Spectrometry...Information, 1999. Hou, Xiaolin, and Per Roos. “ Critical Comparison of radiometric and Mass Spectrometric Methods for the Determination of...NUCLEAR FORENSICS: MEASUREMENTS OF URANIUM OXIDES USING TIME-OF-FLIGHT SECONDARY ION MASS

  5. Controlling coarse woody debris inventory quality: taper and relative size methods

    Treesearch

    C.W. Woodall; J.A. Westfall

    2008-01-01

    Accurately measuring the dimensions of coarse woody debris (CWD) is critical for ensuring the quality of CWD estimates and, hence, for accurately estimating forest ecosystem attributes (e.g., CWD carbon stocks). To improve the quality of CWD dimensional measurements, the distribution of taper (ratio of change in diameter and length) and relative size (RS; ratio of...

  6. Measurement of air-surface exchange of speciated nitrogen and sulfur compounds using a modified MARGA 2S: ? Concentrations and fluxes above a grass field

    EPA Science Inventory

    Improved measurement methods are needed to characterize dry deposition of sulfur and nitrogen compounds to assess ecosystem exposure to nutrients and acidifying compounds and to develop atmospheric deposition budgets in support of critical loads assessments. The purpose of this s...

  7. Measuring School Performance To Improve Student Achievement and To Reward Effective Programs.

    ERIC Educational Resources Information Center

    Heistad, Dave; Spicuzza, Rick

    This paper describes the method that the Minneapolis Public School system (MPS), Minnesota, uses to measure school and student performance. MPS uses a multifaceted system that both captures and accounts for the complexity of a large urban school district. The system incorporates: (1) a hybrid model of critical indicators that report on level of…

  8. Ensuring critical event sequences in high consequence computer based systems as inspired by path expressions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kidd, M.E.C.

    1997-02-01

    The goal of our work is to provide a high level of confidence that critical software driven event sequences are maintained in the face of hardware failures, malevolent attacks and harsh or unstable operating environments. This will be accomplished by providing dynamic fault management measures directly to the software developer and to their varied development environments. The methodology employed here is inspired by previous work in path expressions. This paper discusses the perceived problems, a brief overview of path expressions, the proposed methods, and a discussion of the differences between the proposed methods and traditional path expression usage and implementation.

  9. Defining critical habitats of threatened and endemic reef fishes with a multivariate approach.

    PubMed

    Purcell, Steven W; Clarke, K Robert; Rushworth, Kelvin; Dalton, Steven J

    2014-12-01

    Understanding critical habitats of threatened and endemic animals is essential for mitigating extinction risks, developing recovery plans, and siting reserves, but assessment methods are generally lacking. We evaluated critical habitats of 8 threatened or endemic fish species on coral and rocky reefs of subtropical eastern Australia, by measuring physical and substratum-type variables of habitats at fish sightings. We used nonmetric and metric multidimensional scaling (nMDS, mMDS), Analysis of similarities (ANOSIM), similarity percentages analysis (SIMPER), permutational analysis of multivariate dispersions (PERMDISP), and other multivariate tools to distinguish critical habitats. Niche breadth was widest for 2 endemic wrasses, and reef inclination was important for several species, often found in relatively deep microhabitats. Critical habitats of mainland reef species included small caves or habitat-forming hosts such as gorgonian corals and black coral trees. Hard corals appeared important for reef fishes at Lord Howe Island, and red algae for mainland reef fishes. A wide range of habitat variables are required to assess critical habitats owing to varied affinities of species to different habitat features. We advocate assessments of critical habitats matched to the spatial scale used by the animals and a combination of multivariate methods. Our multivariate approach furnishes a general template for assessing the critical habitats of species, understanding how these vary among species, and determining differences in the degree of habitat specificity. © 2014 Society for Conservation Biology.

  10. Real part of refractive index measurement approach for absorbing liquid.

    PubMed

    Liu, Hao; Ye, Junwei; Yang, Kecheng; Xia, Min; Guo, Wenping; Li, Wei

    2015-07-01

    An algorithm based on use of a reflected refractometer to measure the real part of the refractive index (RI) for an absorbing liquid is presented. The absorption of liquid will blur the division between bright and dark regions on a Fresnel reflective curve. However, the reflective ratio at some incident angles that are less than the critical angle have little sensitivity to absorbability. Unlike common methods that extract RI from reflectivity in critical angle vicinity, the presented method acquires the real RI from reflective ratio at a subcritical angle. Supported by the theoretical analysis and experimental results on a reflected refractometer, we have achieved accuracy better than 3×10(-4) RIU on ink samples with absorption coefficient around 300  cm(-1). Additional tests on Alizarin yellow GG solutions prove that the subcritical algorithm is feasible and of high accuracy.

  11. Assessment and Utility of Frailty Measures in Critical Illness, Cardiology, and Cardiac Surgery.

    PubMed

    Rajabali, Naheed; Rolfson, Darryl; Bagshaw, Sean M

    2016-09-01

    Frailty is a clearly emerging theme in acute care medicine, with obvious prognostic and health resource implications. "Frailty" is a term used to describe a multidimensional syndrome of loss of homeostatic reserves that gives rise to a vulnerability to adverse outcomes after relatively minor stressor events. This is conceptually simple, yet there has been little consensus on the operational definition. The gold standard method to diagnose frailty remains a comprehensive geriatric assessment; however, a variety of validated physical performance measures, judgement-based tools, and multidimensional scales are being applied in critical care, cardiology, and cardiac surgery settings, including open cardiac surgery and transcatheter aortic value replacement. Frailty is common among patients admitted to the intensive care unit and correlates with an increased risk for adverse events, increased resource use, and less favourable patient-centred outcomes. Analogous findings have been described across selected acute cardiology and cardiac surgical settings, in particular those that commonly intersect with critical care services. The optimal methods for screening and diagnosing frailty across these settings remains an active area of investigation. Routine assessment for frailty conceivably has numerous purported benefits for patients, families, health care providers, and health administrators through better informed decision-making regarding treatments or goals of care, prognosis for survival, expectations for recovery, risk of complications, and expected resource use. In this review, we discuss the measurement of frailty and its utility in patients with critical illness and in cardiology and cardiac surgery settings. Copyright © 2016 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  12. Documenting Preservice Teacher Growth through Critical Assessment of Online Lesson Plans

    ERIC Educational Resources Information Center

    Cude, Michelle D.; Haraway, Dana L.

    2017-01-01

    This research explores the question of how students in a social studies methods course improve skills in analyzing and critiquing pre-existing lesson plans. It utilizes a pre-post authentic assessment tool to measure student growth in key skills of lesson plan critique over the course of one semester's methods instruction. The results support the…

  13. Accuracy of blood-glucose measurements using glucose meters and arterial blood gas analyzers in critically ill adult patients: systematic review

    PubMed Central

    2013-01-01

    Introduction Glucose control to prevent both hyperglycemia and hypoglycemia is important in an intensive care unit. Arterial blood gas analyzers and glucose meters are commonly used to measure blood-glucose concentration in an intensive care unit; however, their accuracies are still unclear. Methods We performed a systematic literature search (January 1, 2001, to August 31, 2012) to find clinical studies comparing blood-glucose values measured with glucose meters and/or arterial blood gas analyzers with those simultaneously measured with a central laboratory machine in critically ill adult patients. Results We reviewed 879 articles and found 21 studies in which the accuracy of blood-glucose monitoring by arterial blood gas analyzers and/or glucometers by using central laboratory methods as references was assessed in critically ill adult patients. Of those 21 studies, 11 studies in which International Organization for Standardization criteria, error-grid method, or percentage of values within 20% of the error of a reference were used were selected for evaluation. The accuracy of blood-glucose measurements by arterial blood gas analyzers and glucose meters by using arterial blood was significantly higher than that of measurements with glucose meters by using capillary blood (odds ratios for error: 0.04, P < 0.001; and 0.36, P < 0.001). The accuracy of blood-glucose measurements with arterial blood gas analyzers tended to be higher than that of measurements with glucose meters by using arterial blood (P = 0.20). In the hypoglycemic range (defined as < 81 mg/dl), the incidence of errors using these devices was higher than that in the nonhypoglycemic range (odds ratios for error: arterial blood gas analyzers, 1.86, P = 0.15; glucose meters with capillary blood, 1.84, P = 0.03; glucose meters with arterial blood, 2.33, P = 0.02). Unstable hemodynamics (edema and use of a vasopressor) and use of insulin were associated with increased error of blood glucose monitoring with glucose meters. Conclusions Our literature review showed that the accuracy of blood-glucose measurements with arterial blood gas analyzers was significantly higher than that of measurements with glucose meters by using capillary blood and tended to be higher than that of measurements with glucose meters by using arterial blood. These results should be interpreted with caution because of the large variation of accuracy among devices. Because blood-glucose monitoring was less accurate within or near the hypoglycemic range, especially in patients with unstable hemodynamics or receiving insulin infusion, we should be aware that current blood glucose-monitoring technology has not reached a high enough degree of accuracy and reliability to lead to appropriate glucose control in critically ill patients. PMID:23506841

  14. Measuring critical thinking in pre-registration midwifery students: A multi-method approach.

    PubMed

    Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary

    2018-02-01

    Test the concurrent validity of three newly developed tools (student self-rating, preceptor rating, and reflective writing) that aim to measure critical thinking in midwifery practice. A descriptive matched cohort design was used. Australian research intensive university offering a three year Bachelor of Midwifery programme. Fifty-five undergraduate midwifery students. Students assessed their ability to apply critical thinking in midwifery practice using a 25-item tool and a 5-item subscale in Motivated Strategies for Learning Questionnaire. Clinical preceptors completed a 24-item tool assessing the students' application of critical thinking in practice. Reflective writing by students was assessed by midwifery academics using a 15-item tool. Internal reliability, and concurrent validity were assessed. Correlations, t-tests, multiple regression and confidence levels were calculated for the three scales and associations with student characteristics. The three scales achieved good internal reliability with a Cronbach's alpha coefficient between 0.93 and 0.97. Matched total scores for the three critical thinking scales were moderately correlated; student/preceptor (r=0.36, p<0.01); student/reflective writing (r=0.38, p<0.01); preceptor/reflective writing (r=0.30, p<0.05). All critical thinking mean scores were higher for students with a previous degree, but only significant for reflective writing (t (53)=-2.35, p=0.023). Preceptor ratings were predictive of GPA (beta=0.50, p<0.001, CI=0.10 to 0.30). Students' self-rating scores were predictive of year level (beta=0.32, p<0.05, CI=0.00 to 0.03). The student, preceptor, and reflective writing tools were found to be reliable and valid measures of critical thinking. The three tools can be used individually or in combination to provide students with various sources of feedback to improve their practice. The tools allow formative measurement of critical thinking over time. Further testing of the tools with larger, diverse samples is recommended. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  15. Dynamic balancing of super-critical rotating structures using slow-speed data via parametric excitation

    NASA Astrophysics Data System (ADS)

    Tresser, Shachar; Dolev, Amit; Bucher, Izhak

    2018-02-01

    High-speed machinery is often designed to pass several "critical speeds", where vibration levels can be very high. To reduce vibrations, rotors usually undergo a mass balancing process, where the machine is rotated at its full speed range, during which the dynamic response near critical speeds can be measured. High sensitivity, which is required for a successful balancing process, is achieved near the critical speeds, where a single deflection mode shape becomes dominant, and is excited by the projection of the imbalance on it. The requirement to rotate the machine at high speeds is an obstacle in many cases, where it is impossible to perform measurements at high speeds, due to harsh conditions such as high temperatures and inaccessibility (e.g., jet engines). This paper proposes a novel balancing method of flexible rotors, which does not require the machine to be rotated at high speeds. With this method, the rotor is spun at low speeds, while subjecting it to a set of externally controlled forces. The external forces comprise a set of tuned, response dependent, parametric excitations, and nonlinear stiffness terms. The parametric excitation can isolate any desired mode, while keeping the response directly linked to the imbalance. A software controlled nonlinear stiffness term limits the response, hence preventing the rotor to become unstable. These forces warrant sufficient sensitivity required to detect the projection of the imbalance on any desired mode without rotating the machine at high speeds. Analytical, numerical and experimental results are shown to validate and demonstrate the method.

  16. Sizing Single Cantilever Beam Specimens for Characterizing Facesheet/Core Peel Debonding in Sandwich Structure

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.

    2010-01-01

    This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.

  17. Outcome measures for adult critical care: a systematic review.

    PubMed

    Hayes, J A; Black, N A; Jenkinson, C; Young, J D; Rowan, K M; Daly, K; Ridley, S

    2000-01-01

    1. To identify generic and disease specific measures of impairment, functional status and health-related quality of life that have been used in adult critical care (intensive and high-dependency care) survivors. 2. To review the validity, reliability and responsiveness of the measures in adult critical care survivors. 3. To consider the implications for future policy and to make recommendations for further methodological research. 4. To review what is currently known of the outcome of adult critical care. Searches of electronic databases (MEDLINE, EMBASE, CINAHL, PsycLIT, The Cochrane Library and SIGLE) from 1970 to August 1998. Manual searches of five journals (1985-98) not indexed in electronic databases and relevant conference proceedings (1993-98). Reference lists of six existing reviews, plus snowballing from reference lists of all relevant articles identified. Randomised trials, non-randomised trials (cohort studies) and case series that included data on outcomes after discharge from adult (16 years and over) critical care. If reported, the following data were extracted from each paper: patient characteristics (age, gender, severity of illness, diagnostic category) number of patients eligible for study, follow-up period, number of deaths before follow-up, number and proportion of survivors included in follow-up method of presentation of outcome data - proportion normal as defined by reference values, or aggregate value (e.g. mean or median), or aggregate values plus an indication of variance (e.g. standard deviation or inter-quartile range). Evidence for three measurement properties was sought for each outcome measure that had been used in at least two studies - their validity, reliability and responsiveness in adult critical care. If the authors did not report these aspects explicitly, an attempt was made to use the data provided to provide these measurement properties. For measures that were used in at least ten studies, information on actual reported outcomes were also extracted. MEASURES USED IN CRITICAL CARE: Measures of impairment were largely confined to the respiratory system so are almost certainly not appropriate for many critical care survivors. They can be categorised as respiratory volumes (e.g. vital capacity), gas flow within the respiratory system (e.g. forced expiratory volume in 1 second (FEV1)), pulmonary diffusing capacity (e.g. carbon monoxide diffusing capacity) and visualisation of the upper airway (e.g. bronchoscopy). Multiple tests are often performed. Eight measures of physical functional status were used, five generic and three disease-specific. The most frequently used generic measures were multi-item scales. Two single-item global measures attempted to capture a person's overall activity level or functional status. Five multi-item measures of mental functional status were used, four generic and one specific to trauma patients. The generic measures were either confined to assessing depressive symptoms or also encompassed a measure of anxiety. Measures of neuropsychological functioning relate to a person's cognition, attention, ability to process information and memory. Apart from one single-item measure, which focused on communication level, six multi-item measures were used with critical care survivors. Such measures are particularly appropriate for use with survivors of head injury or other neurological insult and, in that sense, they are disease-specific rather than generic measures. Single item measures of recovery were frequently used but researchers often invented their own, so there was little consistency in the wording. These measures had five principal foci - return to work, return to own home, degree of recovery, productivity and chronic health status. One multi-item scale was also used. (ABSTRACT TRUNCATED)

  18. Measurement of fracture toughness by nanoindentation methods: Recent advances and future challenges

    DOE PAGES

    Sebastiani, Marco; Johanns, K. E.; Herbert, Erik G.; ...

    2015-04-30

    In this study, we describe recent advances and developments for the measurement of fracture toughness at small scales by the use of nanoindentation-based methods including techniques based on micro-cantilever beam bending and micro-pillar splitting. A critical comparison of the techniques is made by testing a selected group of bulk and thin film materials. For pillar splitting, cohesive zone finite element simulations are used to validate a simple relationship between the critical load at failure, the pillar radius, and the fracture toughness for a range of material properties and coating/substrate combinations. The minimum pillar diameter required for nucleation and growth ofmore » a crack during indentation is also estimated. An analysis of pillar splitting for a film on a dissimilar substrate material shows that the critical load for splitting is relatively insensitive to the substrate compliance for a large range of material properties. Experimental results from a selected group of materials show good agreement between single cantilever and pillar splitting methods, while a discrepancy of ~25% is found between the pillar splitting technique and double-cantilever testing. It is concluded that both the micro-cantilever and pillar splitting techniques are valuable methods for micro-scale assessment of fracture toughness of brittle ceramics, provided the underlying assumptions can be validated. Although the pillar splitting method has some advantages because of the simplicity of sample preparation and testing, it is not applicable to most metals because their higher toughness prevents splitting, and in this case, micro-cantilever bend testing is preferred.« less

  19. Claimed effects, outcome variables and methods of measurement for health claims proposed under European Community Regulation 1924/2006 in the area of blood glucose and insulin concentrations.

    PubMed

    Martini, Daniela; Biasini, Beatrice; Zavaroni, Ivana; Bedogni, Giorgio; Musci, Marilena; Pruneti, Carlo; Passeri, Giovanni; Ventura, Marco; Galli, Daniela; Mirandola, Prisco; Vitale, Marco; Dei Cas, Alessandra; Bonadonna, Riccardo C; Del Rio, Daniele

    2018-04-01

    Most requests for authorization to bear health claims under Articles 13(5) and 14 related to blood glucose and insulin concentration/regulation presented to the European Food Safety Authority (EFSA) receive a negative opinion. Reasons for such decisions are mainly ascribable to poor substantiation of the claimed effects. In this scenario, a project was carried out aiming at critically analysing the outcome variables (OVs) and methods of measurement (MMs) to be used to substantiate health claims, with the final purpose to improve the quality of applications provided by stakeholders to EFSA. This manuscript provides a position statement of the experts involved in the project, reporting the results of an investigation aimed to collect, collate and critically analyse the information relevant to claimed effects (CEs), OVs and MMs related to blood glucose and insulin levels and homoeostasis compliant with Regulation 1924/2006. The critical analysis of OVs and MMs was performed with the aid of the pertinent scientific literature and was aimed at defining their appropriateness (alone or in combination with others) to support a specific CE. The results can be used to properly select OVs and MMs in a randomized controlled trial, for an effective substantiation of the claims, using the reference method(s) whenever available. Moreover, results can help EFSA in updating the guidance for the scientific requirements of health claims.

  20. Measuring erosion rates of contaminated cohesive sediments using laboratory and in-situ devices in combination: experiences of investigations in River Elbe and Saale

    NASA Astrophysics Data System (ADS)

    Noack, Markus; Gerbersdorf, Sabine; Hillebrand, Gudrun; Kasimir, Petra; Wieprecht, Silke

    2014-05-01

    Deposition of contaminated sediments in areas of no or low flow velocity such as groyne fields or impounded river stretches represent a significant thread to water quality if long-deposited sediments are remobilized during flood and storm events. In contrast to non-cohesive sediments the dynamics of cohesive sediments is not fully understood mainly because of multiple physico-chemical factors and variable biological influence. Hence, site-specific investigations are required to develop water management strategies as well as modelling approaches to predict the dynamic behavior of cohesive material. The Institute for Modelling Hydraulic and Environmental Systems (IWS, University of Stuttgart) has a strong experience in developing measuring strategies and techniques to deal with the complex interactions between biological and sedimentary characteristics regarding erosion and remobilization of cohesive material. Specifically, the detection of critical shear stresses for incipient motion of cohesive particles has been realized for both one laboratory device (SETEG) and an in-situ device. For site-specific investigations ideally both methods should be combined. The first method (SETEG) includes the on-site extraction of sediment cores allowing for depth-dependent analysis under controlled laboratory conditions, while the second one measures the surface only but reduces possible artifacts due to sediment withdrawal and transport. Both methods were applied at groyne fields and deposition areas of the River Elbe and River Saale, which are both heavily affected by pollution of anthropogenic contaminants mainly originating from the release of chemical industry before 1990. Next to the detection of critical shear stresses and erosion rates, further sedimentary attributes are analyzed such as particle size distribution, water content and density as well as biological attributes such as TOC and microbial mass. The analyses of the sediment cores result in vertical profiles for all sedimentary and biological parameters giving highly complementary insights into the rather complex erosion and resuspension properties of cohesive fine sediments. Further, the detected critical shear stress between the in-situ and laboratory device are compared and especially in case of deviations the biological parameters can be highly beneficial to explain the measured critical shear stress and variances between in situ and laboratory devices. The investigations in both study sites have shown that the joint application of the measuring devices gives comprehensive information which is required to determine the risk of remobilization properly. Keywords: cohesive sediments, critical shear stress, contaminated sediments, incipient motion, biostabilization

  1. Hydrogen sulfide measurement using sulfide dibimane: critical evaluation with electrospray ion trap mass spectrometry

    PubMed Central

    Shen, Xinggui; Chakraborty, Sourav; Dugas, Tammy R; Kevil, Christopher G

    2015-01-01

    Accurate measurement of hydrogen sulfide bioavailability remains a technical challenge due to numerous issues involving sample processing, detection methods used, and actual biochemical products measured. Our group and others have reported that reverse phase HPLC detection of sulfide dibimane (SDB) product from the reaction of H2S/HS− with monobromobimane allows for analytical detection of hydrogen sulfide bioavailability in free and other biochemical forms. However, it remains unclear whether possible interfering contaminants may contribute to HPLC SDB peak readings that may result in inaccurate measurements of bioavailable sulfide. In this study, we critically compared hydrogen sulfide dependent SDB detection using reverse phase HPLC (RP-HPLC) versus quantitative SRM electrospray ionization mass spectrometry (ESI/MS) to obtain greater clarity into the validity of the reverse phase HPLC method for analytical measurement of hydrogen sulfide. Using an LCQ-deca ion-trap mass spectrometer, SDB was identified by ESI/MS positive ion mode, and quantified by selected reaction monitoring (SRM) using hydrocortisone as an internal standard. Collision induced dissociation (CID) parameters were optimized at MS2 level for SDB and hydrocortisone. ESI/MS detection of SDB standard was found to be a log order more sensitive than RP-HPLC with a lower limit of 0.25 nM. Direct comparison of tissue and plasma SDB levels using RP-HPLC and ESI/MS methods revealed comparable sulfide levels in plasma, aorta, heart, lung and brain. Together, these data confirm the use of SDB as valid indicator of H2S bioavailability and highlights differences between analytical detection methods. PMID:24932544

  2. Diagnosing delirium in critically ill children: Validity and reliability of the Pediatric Confusion Assessment Method for the Intensive Care Unit*

    PubMed Central

    Smith, Heidi A. B.; Boyd, Jenny; Fuchs, D. Catherine; Melvin, Kelly; Berry, Pamela; Shintani, Ayumi; Eden, Svetlana K.; Terrell, Michelle K.; Boswell, Tonya; Wolfram, Karen; Sopfe, Jenna; Barr, Frederick E.; Pandharipande, Pratik P.; Ely, E. Wesley

    2013-01-01

    Objective To validate a diagnostic instrument for pediatric delirium in critically ill children, both ventilated and nonventilated, that uses standardized, developmentally appropriate measurements. Design and Setting A prospective observational cohort study investigating the Pediatric Confusion Assessment Method for Intensive Care Unit (pCAM-ICU) patients in the pediatric medical, surgical, and cardiac intensive care unit of a university-based medical center. Patients A total of 68 pediatric critically ill patients, at least 5 years of age, were enrolled from July 1, 2008, to March 30, 2009. Interventions None. Measurements Criterion validity including sensitivity and specificity and interrater reliability were determined using daily delirium assessments with the pCAM-ICU by two critical care clinicians compared with delirium diagnosis by pediatric psychiatrists using Diagnostic and Statistical Manual, 4th Edition, Text Revision criteria. Results A total of 146 paired assessments were completed among 68 enrolled patients with a mean age of 12.2 yrs. Compared with the reference standard for diagnosing delirium, the pCAM-ICU demonstrated a sensitivity of 83% (95% confidence interval, 66–93%), a specificity of 99% (95% confidence interval, 95–100%), and a high interrater reliability (κ = 0.96; 95% confidence interval, 0.74–1.0). Conclusions The pCAM-ICU is a highly valid reliable instrument for the diagnosis of pediatric delirium in critically ill children chronologically and developmentally at least 5 yrs of age. Use of the pCAM-ICU may expedite diagnosis and consultation with neuropsychiatry specialists for treatment of pediatric delirium. In addition, the pCAM-ICU may provide a means for delirium monitoring in future epidemiologic and interventional studies in critically ill children. (Crit Care Med 2011; 39:150–157) PMID:20959783

  3. Accuracy of Subcutaneous Continuous Glucose Monitoring in Critically Ill Adults: Improved Sensor Performance with Enhanced Calibrations

    PubMed Central

    Leelarathna, Lalantha; English, Shane W.; Thabit, Hood; Caldwell, Karen; Allen, Janet M.; Kumareswaran, Kavita; Wilinska, Malgorzata E.; Nodale, Marianna; Haidar, Ahmad; Evans, Mark L.; Burnstein, Rowan

    2014-01-01

    Abstract Objective: Accurate real-time continuous glucose measurements may improve glucose control in the critical care unit. We evaluated the accuracy of the FreeStyle® Navigator® (Abbott Diabetes Care, Alameda, CA) subcutaneous continuous glucose monitoring (CGM) device in critically ill adults using two methods of calibration. Subjects and Methods: In a randomized trial, paired CGM and reference glucose (hourly arterial blood glucose [ABG]) were collected over a 48-h period from 24 adults with critical illness (mean±SD age, 60±14 years; mean±SD body mass index, 29.6±9.3 kg/m2; mean±SD Acute Physiology and Chronic Health Evaluation score, 12±4 [range, 6–19]) and hyperglycemia. In 12 subjects, the CGM device was calibrated at variable intervals of 1–6 h using ABG. In the other 12 subjects, the sensor was calibrated according to the manufacturer's instructions (1, 2, 10, and 24 h) using arterial blood and the built-in point-of-care glucometer. Results: In total, 1,060 CGM–ABG pairs were analyzed over the glucose range from 4.3 to 18.8 mmol/L. Using enhanced calibration median (interquartile range) every 169 (122–213) min, the absolute relative deviation was lower (7.0% [3.5, 13.0] vs. 12.8% [6.3, 21.8], P<0.001), and the percentage of points in the Clarke error grid Zone A was higher (87.8% vs. 70.2%). Conclusions: Accuracy of the Navigator CGM device during critical illness was comparable to that observed in non–critical care settings. Further significant improvements in accuracy may be obtained by frequent calibrations with ABG measurements. PMID:24180327

  4. Laser-induced breakdown spectroscopy (LIBS) to measure quantitatively soil carbon with emphasis on soil organic carbon. A review.

    PubMed

    Senesi, Giorgio S; Senesi, Nicola

    2016-09-28

    Soil organic carbon (OC) measurement is a crucial factor for quantifying soil C pools and inventories and monitoring the inherent temporal and spatial heterogeneity and changes of soil OC content. These are relevant issues in addressing sustainable management of terrestrial OC aiming to enhance C sequestration in soil, thus mitigating the impact of increasing CO2 concentration in the atmosphere and related effects on global climate change. Nowadays, dry combustion by an elemental analyzer or wet combustion by dichromate oxidation of the soil sample are the most recommended and commonly used methods for quantitative soil OC determination. However, the unanimously recognized uncertainties and limitations of these classical laboursome methods have prompted research efforts focusing on the development and application of more advanced and appealing techniques and methods for the measurement of soil OC in the laboratory and possibly in situ in the field. Among these laser-induced breakdown spectroscopy (LIBS) has raised the highest interest for its unique advantages. After an introduction and a highlight of the LIBS basic principles, instrumentation, methodologies and supporting chemometric methods, the main body of this review provides an historical and critical overview of the developments and results obtained up-to-now by the application of LIBS to the quantitative measurement of soil C and especially OC content. A brief critical summary of LIBS advantages and limitations/drawbacks including some final remarks and future perspectives concludes this review. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. INNOVATIVE METHODS FOR EMISSION INVENTORY DEVELOPMENT AND EVALUATION: WORKSHOP SYNTHESIS

    EPA Science Inventory

    Emission inventories are key databases for evaluating, managing, and regulating air pollutants. Refinements and innovations in instruments that measure air pollutants, models that calculate emissions, and techniques for data management and uncertainty assessment are critical to ...

  6. Estimating core temperature in infants and children after cardiac surgery: a comparison of six methods.

    PubMed

    Maxton, Fiona J C; Justin, Linda; Gillies, Donna

    2004-01-01

    Monitoring temperature in critically ill children is an important component of care, yet the accuracy of methods is often questioned. Temperature measured in the pulmonary artery is considered the 'gold standard', but this route is unsuitable for the majority of patients. An accurate, reliable and less invasive method is, however, yet to be established in paediatric intensive care work. To determine which site most closely reflects core temperature in babies and children following cardiac surgery, by comparing pulmonary artery temperature to the temperature measured at rectal, bladder, nasopharyngeal, axillary and tympanic sites. A convenience sample of 19 postoperative cardiac patients was studied. Temperature was recorded as a continuous measurement from pulmonary artery, rectal, nasopharyngeal and bladder sites. Axillary and tympanic temperatures were recorded at 30 minute intervals for 6 1/2 hours postoperatively. The small sample size of 19 infants and children limits the generalizability of the study. Repeated measures analysis of variance demonstrated no significant difference between pulmonary artery and bladder temperatures, and pulmonary artery and nasopharyngeal temperatures. Intraclass correlation showed that agreement was greatest between pulmonary artery temperature and temperature measured by bladder catheter. There was a significant difference between pulmonary artery temperature and temperature measured at rectal, tympanic and pulmonary artery and axillary sites. Repeated measures analysis showed a significant lag between pulmonary artery and rectal temperature of between 0 and 150 minutes after the 6-hour measurement period. In this study, bladder temperature was shown to be the best estimate of pulmonary artery temperature, closely followed by the temperature measured by nasopharyngeal probe. The results support the use of bladder or nasopharyngeal catheters to monitor temperature in critically ill children after cardiac surgery.

  7. Full Core TREAT Kinetics Demonstration Using Rattlesnake/BISON Coupling Within MAMMOTH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ortensi, Javier; DeHart, Mark D.; Gleicher, Frederick N.

    2015-08-01

    This report summarizes key aspects of research in evaluation of modeling needs for TREAT transient simulation. Using a measured TREAT critical measurement and a transient for a small, experimentally simplified core, Rattlesnake and MAMMOTH simulations are performed building from simple infinite media to a full core model. Cross sections processing methods are evaluated, various homogenization approaches are assessed and the neutronic behavior of the core studied to determine key modeling aspects. The simulation of the minimum critical core with the diffusion solver shows very good agreement with the reference Monte Carlo simulation and the experiment. The full core transient simulationmore » with thermal feedback shows a significantly lower power peak compared to the documented experimental measurement, which is not unexpected in the early stages of model development.« less

  8. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    PubMed

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.

  9. Comparison of Direct and Indirect Methods of Measuring Arterial Blood Pressure in Healthy Male Rhesus Macaques (Macaca mulatta).

    PubMed

    France, Logan K; Vermillion, Meghan S; Garrett, Caroline M

    2018-01-01

    Blood pressure is a critical parameter for evaluating cardiovascular health, assessing effects of drugs and procedures, monitoring physiologic status during anesthesia, and making clinical decisions. The placement of an arterial catheter is the most direct and accurate method for measuring blood pressure; however, this approach is invasive and of limited use during brief sedated examinations. The objective of this study was to determine which method of indirect blood pressure monitoring was most accurate compared with measurement by direct arterial catheterization. In addition, we sought to determine the relative accuracy of each indirect method (compared with direct arterial measurement) at a given body location and to assess whether the accuracy of each indirect method was dependent on body location. We compared direct blood pressure measurements by means of catheterization of the saphenous artery with oscillometric and ultrasonic Doppler flow detection measurements at 3 body locations (forearm, distal leg, and tail base) in 16 anesthetized, male rhesus macaques. The results indicate that oscillometry at the forearm is the best indirect method and location for accurately and consistently measuring blood pressure in healthy male rhesus macaques.

  10. [Application of three heat pulse technique-based methods to determine the stem sap flow].

    PubMed

    Wang, Sheng; Fan, Jun

    2015-08-01

    It is of critical importance to acquire tree transpiration characters through sap flow methodology to understand tree water physiology, forest ecology and ecosystem water exchange. Tri-probe heat pulse sensors, which are widely utilized in soil thermal parameters and soil evaporation measurement, were applied to implement Salix matsudana sap flow density (Vs) measurements via heat-ratio method (HRM), T-Max method (T-Max) and single-probe heat pulse probe (SHPP) method, and comparative analysis was conducted with additional Grainer's thermal diffusion probes (TDP) measured results. The results showed that, it took about five weeks to reach a stable measurement stage after TPHP installation, Vs measured with three methods in the early stage after installation was 135%-220% higher than Vs in the stable measurement stage, and Vs estimated via HRM, T-Max and SHPP methods were significantly linearly correlated with Vs estimated via TDP method, with R2 of 0.93, 0.73 and 0.91, respectively, and R2 for Vs measured by SHPP and HRM reached 0.94. HRM had relatively higher precision in measuring low rates and reverse sap flow. SHPP method seemed to be very promising to measure sap flow for configuration simplicity and high measuring accuracy, whereas it couldn' t distinguish directions of flow. T-Max method had relatively higher error in sap flow measurement, and it couldn' t measure sap flow below 5 cm3 · cm(-2) · h(-1), thus this method could not be used alone, however it could measure thermal diffusivity for calculating sap flow when other methods were imposed. It was recommended to choose a proper method or a combination of several methods to measure stem sap flow, based on specific research purpose.

  11. Application of process analytical technology for monitoring freeze-drying of an amorphous protein formulation: use of complementary tools for real-time product temperature measurements and endpoint detection.

    PubMed

    Schneid, Stefan C; Johnson, Robert E; Lewis, Lavinia M; Stärtzel, Peter; Gieseler, Henning

    2015-05-01

    Process analytical technology (PAT) and quality by design have gained importance in all areas of pharmaceutical development and manufacturing. One important method for monitoring of critical product attributes and process optimization in laboratory scale freeze-drying is manometric temperature measurement (MTM). A drawback of this innovative technology is that problems are encountered when processing high-concentrated amorphous materials, particularly protein formulations. In this study, a model solution of bovine serum albumin and sucrose was lyophilized at both conservative and aggressive primary drying conditions. Different temperature sensors were employed to monitor product temperatures. The residual moisture content at primary drying endpoints as indicated by temperature sensors and batch PAT methods was quantified from extracted sample vials. The data from temperature probes were then used to recalculate critical product parameters, and the results were compared with MTM data. The drying endpoints indicated by the temperature sensors were not suitable for endpoint indication, in contrast to the batch methods endpoints. The accuracy of MTM Pice data was found to be influenced by water reabsorption. Recalculation of Rp and Pice values based on data from temperature sensors and weighed vials was possible. Overall, extensive information about critical product parameters could be obtained using data from complementary PAT tools. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.

  12. Time-resolved brightness measurements by streaking

    NASA Astrophysics Data System (ADS)

    Torrance, Joshua S.; Speirs, Rory W.; McCulloch, Andrew J.; Scholten, Robert E.

    2018-03-01

    Brightness is a key figure of merit for charged particle beams, and time-resolved brightness measurements can elucidate the processes involved in beam creation and manipulation. Here we report on a simple, robust, and widely applicable method for the measurement of beam brightness with temporal resolution by streaking one-dimensional pepperpots, and demonstrate the technique to characterize electron bunches produced from a cold-atom electron source. We demonstrate brightness measurements with 145 ps temporal resolution and a minimum resolvable emittance of 40 nm rad. This technique provides an efficient method of exploring source parameters and will prove useful for examining the efficacy of techniques to counter space-charge expansion, a critical hurdle to achieving single-shot imaging of atomic scale targets.

  13. Cerebral blood flow and autoregulation: current measurement techniques and prospects for noninvasive optical methods

    PubMed Central

    Fantini, Sergio; Sassaroli, Angelo; Tgavalekos, Kristen T.; Kornbluth, Joshua

    2016-01-01

    Abstract. Cerebral blood flow (CBF) and cerebral autoregulation (CA) are critically important to maintain proper brain perfusion and supply the brain with the necessary oxygen and energy substrates. Adequate brain perfusion is required to support normal brain function, to achieve successful aging, and to navigate acute and chronic medical conditions. We review the general principles of CBF measurements and the current techniques to measure CBF based on direct intravascular measurements, nuclear medicine, X-ray imaging, magnetic resonance imaging, ultrasound techniques, thermal diffusion, and optical methods. We also review techniques for arterial blood pressure measurements as well as theoretical and experimental methods for the assessment of CA, including recent approaches based on optical techniques. The assessment of cerebral perfusion in the clinical practice is also presented. The comprehensive description of principles, methods, and clinical requirements of CBF and CA measurements highlights the potentially important role that noninvasive optical methods can play in the assessment of neurovascular health. In fact, optical techniques have the ability to provide a noninvasive, quantitative, and continuous monitor of CBF and autoregulation. PMID:27403447

  14. Strain Measurements within Fibre Boards. Part II: Strain Concentrations at the Crack Tip of MDF Specimens Tested by the Wedge Splitting Method

    PubMed Central

    Sinn, Gerhard; Müller, Ulrich; Konnerth, Johannes; Rathke, Jörn

    2012-01-01

    This is the second part of an article series where the mechanical and fracture mechanical properties of medium density fiberboard (MDF) were studied. While the first part of the series focused on internal bond strength and density profiles, this article discusses the fracture mechanical properties of the core layer. Fracture properties were studied with a wedge splitting setup. The critical stress intensity factors as well as the specific fracture energies were determined. Critical stress intensity factors were calculated from maximum splitting force and two-dimensional isotropic finite elements simulations of the specimen geometry. Size and shape of micro crack zone were measured with electronic laser speckle interferometry. The process zone length was approx. 5 mm. The specific fracture energy was determined to be 45.2 ± 14.4 J/m2 and the critical stress intensity factor was 0.11 ± 0.02 MPa.

  15. On the Use of the Immediate Recall Task as a Measure of Second Language Reading Comprehension

    ERIC Educational Resources Information Center

    Chang, Yuh-Fang

    2006-01-01

    The immediate written recall task, a widely used measure of both first language (L1) and second language (L2) reading comprehension, has been advocated over traditional test methods such as multiple choice, cloze tests and open-ended questions because it is a direct and integrative assessment task. It has been, however, criticized as requiring…

  16. Measuring the Friendships of Young Children with Disabilities: A Review of the Literature

    ERIC Educational Resources Information Center

    Meyer, Lori E.; Ostrosky, Michaelene M.

    2014-01-01

    The purpose of this article is to describe what has been learned over the past 35+ years of research on the friendships of young children with disabilities. An extensive literature review was conducted to critically examine the purposes that guided the friendship studies, the methods used to measure friendships, and the major findings of these…

  17. Evaluation of English Achievement Test: A Comparison between High and Low Achievers amongst Selected Elementary School Students of Pakistan

    ERIC Educational Resources Information Center

    Haider, Zubair; Latif, Farah; Akhtar, Samina; Mushtaq, Maria

    2012-01-01

    Validity, reliability and item analysis are critical to the process of evaluating the quality of an educational measurement. The present study evaluates the quality of an assessment constructed to measure elementary school student's achievement in English. In this study, the survey model of descriptive research was used as a research method.…

  18. Emotional Arousal and Regulation: Further Evidence of the Validity of the "How I Feel" Questionnaire for Use with School-Age Children

    ERIC Educational Resources Information Center

    Ciucci, Enrica; Baroncelli, Andrea; Grazzani, Ilaria; Ornaghi, Veronica; Caprin, Claudia

    2016-01-01

    Background: The ability to understand and manage emotional experience is critical to children's health. This study confirmed the validity of the How I Feel (HIF) Questionnaire, a measure of children's emotional arousal and regulation, exploring its associations with measures of emotional and social functioning. Methods: The sample was comprised of…

  19. Probabilistic Scenario-based Seismic Risk Analysis for Critical Infrastructures Method and Application for a Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Klügel, J.

    2006-12-01

    Deterministic scenario-based seismic hazard analysis has a long tradition in earthquake engineering for developing the design basis of critical infrastructures like dams, transport infrastructures, chemical plants and nuclear power plants. For many applications besides of the design of infrastructures it is of interest to assess the efficiency of the design measures taken. These applications require a method allowing to perform a meaningful quantitative risk analysis. A new method for a probabilistic scenario-based seismic risk analysis has been developed based on a probabilistic extension of proven deterministic methods like the MCE- methodology. The input data required for the method are entirely based on the information which is necessary to perform any meaningful seismic hazard analysis. The method is based on the probabilistic risk analysis approach common for applications in nuclear technology developed originally by Kaplan & Garrick (1981). It is based (1) on a classification of earthquake events into different size classes (by magnitude), (2) the evaluation of the frequency of occurrence of events, assigned to the different classes (frequency of initiating events, (3) the development of bounding critical scenarios assigned to each class based on the solution of an optimization problem and (4) in the evaluation of the conditional probability of exceedance of critical design parameters (vulnerability analysis). The advantage of the method in comparison with traditional PSHA consists in (1) its flexibility, allowing to use different probabilistic models for earthquake occurrence as well as to incorporate advanced physical models into the analysis, (2) in the mathematically consistent treatment of uncertainties, and (3) in the explicit consideration of the lifetime of the critical structure as a criterion to formulate different risk goals. The method was applied for the evaluation of the risk of production interruption losses of a nuclear power plant during its residual lifetime.

  20. Electron-Beam Atomic Spectroscopy for In Situ Measurements of Melt Composition for Refractory Metals: Analysis of Fundamental Physics and Plasma Models

    NASA Astrophysics Data System (ADS)

    Gasper, Paul Joseph; Apelian, Diran

    2015-04-01

    Electron-beam (EB) melting is used for the processing of refractory metals, such as Ta, Nb, Mo, and W. These metals have high value and are critical to many industries, including the semiconductor, aerospace, and nuclear industries. EB melting can also purify secondary feedstock, enabling the recovery and recycling of these materials. Currently, there is no method for measuring melt composition in situ during EB melting. Optical emission spectroscopy of the plasma generated by EB impact with vapor above the melt, a technique here termed electron-beam atomic spectroscopy, can be used to measure melt composition in situ, allowing for analysis of melt dynamics, facilitating improvement of EB melting processes and aiding recycling and recovery of these critical and high-value metals. This paper reviews the physics of the plasma generation by EB impact by characterizing the densities and energies of electrons, ions, and neutrals, and describing the interactions between them. Then several plasma models are introduced and their suitability to this application analyzed. Lastly, a potential method for calibration-free composition measurement is described and the challenges for implementation addressed.

  1. Predicting speech intelligibility in noise for hearing-critical jobs

    NASA Astrophysics Data System (ADS)

    Soli, Sigfrid D.; Laroche, Chantal; Giguere, Christian

    2003-10-01

    Many jobs require auditory abilities such as speech communication, sound localization, and sound detection. An employee for whom these abilities are impaired may constitute a safety risk for himself or herself, for fellow workers, and possibly for the general public. A number of methods have been used to predict these abilities from diagnostic measures of hearing (e.g., the pure-tone audiogram); however, these methods have not proved to be sufficiently accurate for predicting performance in the noise environments where hearing-critical jobs are performed. We have taken an alternative and potentially more accurate approach. A direct measure of speech intelligibility in noise, the Hearing in Noise Test (HINT), is instead used to screen individuals. The screening criteria are validated by establishing the empirical relationship between the HINT score and the auditory abilities of the individual, as measured in laboratory recreations of real-world workplace noise environments. The psychometric properties of the HINT enable screening of individuals with an acceptable amount of error. In this presentation, we will describe the predictive model and report the results of field measurements and laboratory studies used to provide empirical validation of the model. [Work supported by Fisheries and Oceans Canada.

  2. Penetration depth of MgB2 measured using Josephson junctions and SQUIDs

    NASA Astrophysics Data System (ADS)

    Cunnane, Daniel; Zhuang, Chenggang; Chen, Ke; Xi, X. X.; Yong, Jie; Lemberger, T. R.

    2013-02-01

    The penetration depth of MgB2 was measured using two methods of different mechanisms. The first method used MgB2 Josephson junctions and the magnetic field dependence of the junction critical current. The second method deduced the penetration depth from the inductance of a MgB2 microstrip used to modulate the voltage of a MgB2 DC SQUID. The two methods showed a consistent value of the low-temperature penetration depth for MgB2 to be about 40 nm. Both the small penetration depth value and its temperature dependence are in agreement with a microscopic theory for MgB2 in the clean limit.

  3. Specifying and calibrating instrumentations for wideband electronic power measurements. [in switching circuits

    NASA Technical Reports Server (NTRS)

    Lesco, D. J.; Weikle, D. H.

    1980-01-01

    The wideband electric power measurement related topics of electronic wattmeter calibration and specification are discussed. Tested calibration techniques are described in detail. Analytical methods used to determine the bandwidth requirements of instrumentation for switching circuit waveforms are presented and illustrated with examples from electric vehicle type applications. Analog multiplier wattmeters, digital wattmeters and calculating digital oscilloscopes are compared. The instrumentation characteristics which are critical to accurate wideband power measurement are described.

  4. Implementing Eratosthenes' Discovery in the Classroom: Educational Difficulties Needing Attention

    ERIC Educational Resources Information Center

    Decamp, Nicolas; de Hosson, Cecile

    2012-01-01

    This paper presents a critical analysis of the accepted educational use of the method performed by Eratosthenes to measure the circumference of Earth which is often considered as a relevant means of dealing with issues related to the nature of science and its history. This method relies on a number of assumptions among which the parallelism of sun…

  5. Estimated and measured bridge scour at selected sites in North Dakota, 1990-97

    USGS Publications Warehouse

    Williams-Sether, Tara

    1999-01-01

    A Level 2 bridge scour method was used to estimate scour depths at 36 selected bridge sites located on the primary road system throughout North Dakota. Of the 36 bridge sites analyzed, the North Dakota Department of Transportation rated 15 as scour critical. Flood and scour data were collected at 19 of the 36 selected bridge sites during 1990-97. Data collected were sufficient to estimate pier scour but not contraction or abutment scour. Estimated pier scour depths ranged from -10.6 to -1.2 feet, and measured bed-elevation changes at piers ranged from -2.31 to +2.37 feet. Comparisons between the estimated pier scour depths and the measured bed-elevation changes indicate that the pier scour equations overestimate scour at bridges in North Dakota.A Level 1.5 bridge scour method also was used to estimate scour depths at 495 bridge sites located on the secondary road system throughout North Dakota. The North Dakota Department of Transportation determined that 26 of the 495 bridge sites analyzed were potentially scour critical.

  6. Rapid determination of surfactant critical micelle concentration in aqueous solutions using fiber-optic refractive index sensing.

    PubMed

    Tan, Chun Hua; Huang, Zhen Jian; Huang, Xu Guang

    2010-06-01

    We describe a simple and rapid method for determining the critical micelle concentration (CMC) of surfactants from fiber-optic measurements of refractive index. The refractive index of an aqueous surfactant solution was monitored as the surfactant concentration was increased using an automated dispensing system. On reaching the surfactant's CMC value, an abrupt change was observed in the rate of increase of the refractive index with increasing concentration. The measurement system provides rapid semiautomatic data collection and analysis, increasing the precision, sensitivity, and range of applicability of the technique while substantially decreasing the amount of manual intervention required. Measurements of CMC for sodium dodecyl sulfate (8.10mM), cetyltrimethylammonium chloride (1.58mM), and Triton X-100 (0.21mM) were in excellent agreement with values previously reported in the literature. The method is applicable to cationic, anionic, and nonionic surfactants, and it offers a facile, in situ, and sensitive means of detecting micelle formation over a broad range of CMC values larger than 10(-1)mM. Copyright 2010 Elsevier Inc. All rights reserved.

  7. Assessing glomerular filtration rate (GFR) in critically ill patients with acute kidney injury - true GFR versus urinary creatinine clearance and estimating equations

    PubMed Central

    2013-01-01

    Introduction Estimation of kidney function in critically ill patients with acute kidney injury (AKI), is important for appropriate dosing of drugs and adjustment of therapeutic strategies, but challenging due to fluctuations in kidney function, creatinine metabolism and fluid balance. Data on the agreement between estimating and gold standard methods to assess glomerular filtration rate (GFR) in early AKI are lacking. We evaluated the agreement of urinary creatinine clearance (CrCl) and three commonly used estimating equations, the Cockcroft Gault (CG), the Modification of Diet in Renal Disease (MDRD) and the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, in comparison to GFR measured by the infusion clearance of chromium-ethylenediaminetetraacetic acid (51Cr-EDTA), in critically ill patients with early AKI after complicated cardiac surgery. Methods Thirty patients with early AKI were studied in the intensive care unit, 2 to 12 days after complicated cardiac surgery. The infusion clearance for 51Cr-EDTA obtained as a measure of GFR (GFR51Cr-EDTA) was calculated from the formula: GFR (mL/min/1.73m2) = (51Cr-EDTA infusion rate × 1.73)/(arterial 51Cr-EDTA × body surface area) and compared with the urinary CrCl and the estimated GFR (eGFR) from the three estimating equations. Urine was collected in two 30-minute periods to measure urine flow and urine creatinine. Urinary CrCl was calculated from the formula: CrCl (mL/min/1.73m2) = (urine volume × urine creatinine × 1.73)/(serum creatinine × 30 min × body surface area). Results The within-group error was lower for GFR51Cr-EDTA than the urinary CrCl method, 7.2% versus 55.0%. The between-method bias was 2.6, 11.6, 11.1 and 7.39 ml/min for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. The error was 103%, 68.7%, 67.7% and 68.0% for eGFRCrCl, eGFRMDRD, eGFRCKD-EPI and eGFRCG, respectively, when compared to GFR51Cr-EDTA. Conclusions The study demonstrated poor precision of the commonly utilized urinary CrCl method for assessment of GFR in critically ill patients with early AKI, suggesting that this should not be used as a reference method when validating new methods for assessing kidney function in this patient population. The commonly used estimating equations perform poorly when estimating GFR, with high biases and unacceptably high errors. PMID:23767877

  8. A Liquid Level Measurement Technique Outside a Sealed Metal Container Based on Ultrasonic Impedance and Echo Energy

    PubMed Central

    Zhang, Bin; Wei, Yue-Juan; Liu, Wen-Yi; Zhang, Yan-Jun; Yao, Zong; Zhao, Li-Hui; Xiong, Ji-Jun

    2017-01-01

    The proposed method for measuring the liquid level focuses on the ultrasonic impedance and echo energy inside a metal wall, to which the sensor is attached directly, not on ultrasonic waves that penetrate the gas–liquid medium of a container. Firstly, by analyzing the sound field distribution characteristics of the sensor in a metal wall, this paper proposes the concept of an "energy circle" and discusses how to calculate echo energy under three different states in detail. Meanwhile, an ultrasonic transmitting and receiving circuit is designed to convert the echo energy inside the energy circle into its equivalent electric power. Secondly, in order to find the two critical states of the energy circle in the process of liquid level detection, a program is designed to help with calculating two critical positions automatically. Finally, the proposed method is evaluated through a series of experiments, and the experimental results indicate that the proposed method is effective and accurate in calibration of the liquid level outside a sealed metal container. PMID:28106857

  9. Understanding health economic analysis in critical care: insights from recent randomized controlled trials.

    PubMed

    Sud, Sachin; Cuthbertson, Brian H

    2011-10-01

    The article reviews the methods of health economic analysis (HEA) in clinical trials of critically ill patients. Emphasis is placed on the usefulness of HEA in the context of positive and 'no effect' studies, with recent examples. The need to control costs and promote effective spending in caring for the critically ill has garnered considerable attention due to the high cost of critical illness. Many clinical trials focus on short-term mortality, ignoring costs and quality of life, and fail to change clinical practice or promote efficient use of resources. Incorporating HEA into clinical trials is a possible solution. Such studies have shown some interventions, although expensive, provide good value, whereas others should be withdrawn from clinical practice. Incorporating HEA into randomized controlled trials (RCTs) requires careful attention to collect all relevant costs. Decision trees, modeling assumptions and methods for collecting costs and measuring outcomes should be planned and published beforehand to minimize bias. Costs and cost-effectiveness are potentially useful outcomes in RCTs of critically ill patients. Future RCTs should incorporate parallel HEA to provide both economic outcomes, which are important to the community, alongside patient-centered outcomes, which are important to individuals.

  10. Measuring impedance in congestive heart failure: Current options and clinical applications

    PubMed Central

    Tang, W. H. Wilson; Tong, Wilson

    2011-01-01

    Measurement of impedance is becoming increasingly available in the clinical setting as a tool for assessing hemodynamics and volume status in patients with heart failure. The 2 major categories of impedance assessment are the band electrode method and the implanted device lead method. The exact sources of the impedance signal are complex and can be influenced by physiologic effects such as blood volume, fluid, and positioning. This article provides a critical review of our current understanding and promises of impedance measurements, the techniques that have evolved, as well as the evidence and limitations regarding their clinical applications in the setting of heart failure management. PMID:19249408

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Attota, Ravikiran, E-mail: Ravikiran.attota@nist.gov; Dixson, Ronald G.

    We experimentally demonstrate that the three-dimensional (3-D) shape variations of nanometer-scale objects can be resolved and measured with sub-nanometer scale sensitivity using conventional optical microscopes by analyzing 4-D optical data using the through-focus scanning optical microscopy (TSOM) method. These initial results show that TSOM-determined cross-sectional (3-D) shape differences of 30 nm–40 nm wide lines agree well with critical-dimension atomic force microscope measurements. The TSOM method showed a linewidth uncertainty of 1.22 nm (k = 2). Complex optical simulations are not needed for analysis using the TSOM method, making the process simple, economical, fast, and ideally suited for high volume nanomanufacturing process monitoring.

  12. Critical Science Instrument Alignment of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

    NASA Technical Reports Server (NTRS)

    Rohrbach, Scott O.; Kubalak, David A.; Gracey, Renee M.; Sabatke, Derek S.; Howard, Joseph M.; Telfer, Randal C.; Zielinski, Thomas P.

    2016-01-01

    This paper describes the critical instrument alignment terms associated with the six-degree of freedom alignment of each the Science Instrument (SI) in the James Webb Space Telescope (JWST), including focus, pupil shear, pupil clocking, and boresight. We present the test methods used during cryogenic-vacuum tests to directly measure the performance of each parameter, the requirements levied on each, and the impact of any violations of these requirements at the instrument and Observatory level.

  13. Experimental Investigations Of The Influence Of Pressure On Critical Extinction Conditions Of Laminar Nonpremixed Flames Burning Condensed Hydrocarbon Fuels, Jet Fuels, And Surrogates

    DTIC Science & Technology

    2014-10-25

    cycloalkanes, aromatics, and alkenes [3,23–26]. On average, the composition by volume is approximately 60% alkanes, 20% cycloalkanes, 18% aromatics, and 2... alkenes [26]. Efforts to develop chemical-kinetic models that accurately describe the combustion of these practical fuels are critical to the development... method also allows for measurements of fuel mass burning rates by recording the required fuel feed rate to maintain the fuel cup level under steady

  14. 24-Hour protein, arginine and citrulline metabolism in fed critically ill children – a stable isotope tracer study

    PubMed Central

    de Betue, Carlijn T.I.; Garcia Casal, Xiomara C.; van Waardenburg, Dick A.; Schexnayder, Stephen M.; Joosten, Koen F.M.; Deutz, Nicolaas E.P.; Engelen, Marielle P.K.J.

    2017-01-01

    Background & aims The reference method to study protein and arginine metabolism in critically ill children is measuring plasma amino acid appearances with stable isotopes during a short (4–8h) time period and extrapolate results to 24-hour. However, 24-hour measurements may be variable due to critical illness related factors and a circadian rhythm could be present. Since only short duration stable isotope studies in critically ill children have been conducted before, the aim of this study was to investigate 24-hour appearance of specific amino acids representing protein and arginine metabolism, with stable isotope techniques in continuously fed critically ill children. Methods In eight critically ill children, admitted to the pediatric (n=4) or cardiovascular (n=4) intensive care unit, aged 0–10 years, receiving continuous (par)enteral nutrition with protein intake 1.0–3.7 g/kg/day, a 24-hour stable isotope tracer protocol was carried out. L-[ring-2H5]-phenylalanine, L-[3,3-2H2]-tyrosine, L-[5,5,5-2H3]-leucine, L-[guanido-15N2]-arginine and L-[5-13C-3,3,4,4-2H4]-citrulline were infused intravenously and L-[15N]-phenylalanine and L-[1-13C]leucine enterally. Arterial blood was sampled every hour. Results Coefficients of variation, representing intra-individual variability, of the amino acid appearances of phenylalanine, tyrosine, leucine, arginine and citrulline were high, on average 14–19% for intravenous tracers and 23–26% for enteral tracers. No evident circadian rhythm was present. The pattern and overall 24-hour level of whole body protein balance differed per individual. Conclusions In continuously fed stable critically ill children, the amino acid appearances of phenylalanine, tyrosine, leucine, arginine and citrulline show high variability. This should be kept in mind when performing stable isotope studies in this population. There was no apparent circadian rhythm. PMID:28089618

  15. A statistical approach to determining criticality of residual host cell DNA.

    PubMed

    Yang, Harry; Wei, Ziping; Schenerman, Mark

    2015-01-01

    We propose a method for determining the criticality of residual host cell DNA, which is characterized through two attributes, namely the size and amount of residual DNA in biopharmaceutical product. By applying a mechanistic modeling approach to the problem, we establish the linkage between residual DNA and product safety measured in terms of immunogenicity, oncogenicity, and infectivity. Such a link makes it possible to establish acceptable ranges of residual DNA size and amount. Application of the method is illustrated through two real-life examples related to a vaccine manufactured in Madin Darby Canine Kidney cell line and a monoclonal antibody using Chinese hamster ovary (CHO) cell line as host cells.

  16. Method to measure efficiently rare fluctuations of turbulence intensity for turbulent-laminar transitions in pipe flows

    NASA Astrophysics Data System (ADS)

    Nemoto, Takahiro; Alexakis, Alexandros

    2018-02-01

    The fluctuations of turbulence intensity in a pipe flow around the critical Reynolds number is difficult to study but important because they are related to turbulent-laminar transitions. We here propose a rare-event sampling method to study such fluctuations in order to measure the time scale of the transition efficiently. The method is composed of two parts: (i) the measurement of typical fluctuations (the bulk part of an accumulative probability function) and (ii) the measurement of rare fluctuations (the tail part of the probability function) by employing dynamics where a feedback control of the Reynolds number is implemented. We apply this method to a chaotic model of turbulent puffs proposed by Barkley and confirm that the time scale of turbulence decay increases super exponentially even for high Reynolds numbers up to Re =2500 , where getting enough statistics by brute-force calculations is difficult. The method uses a simple procedure of changing Reynolds number that can be applied even to experiments.

  17. Decoupled Method for Reconstruction of Surface Conditions From Internal Temperatures On Ablative Materials With Uncertain Recession Model

    NASA Technical Reports Server (NTRS)

    Oliver, A. Brandon

    2017-01-01

    Obtaining measurements of flight environments on ablative heat shields is both critical for spacecraft development and extremely challenging due to the harsh heating environment and surface recession. Thermocouples installed several millimeters below the surface are commonly used to measure the heat shield temperature response, but an ill-posed inverse heat conduction problem must be solved to reconstruct the surface heating environment from these measurements. Ablation can contribute substantially to the measurement response making solutions to the inverse problem strongly dependent on the recession model, which is often poorly characterized. To enable efficient surface reconstruction for recession model sensitivity analysis, a method for decoupling the surface recession evaluation from the inverse heat conduction problem is presented. The decoupled method is shown to provide reconstructions of equivalent accuracy to the traditional coupled method but with substantially reduced computational effort. These methods are applied to reconstruct the environments on the Mars Science Laboratory heat shield using diffusion limit and kinetically limited recession models.

  18. Methods for consistent forewarning of critical events across multiple data channels

    DOEpatents

    Hively, Lee M.

    2006-11-21

    This invention teaches further method improvements to forewarn of critical events via phase-space dissimilarity analysis of data from biomedical equipment, mechanical devices, and other physical processes. One improvement involves conversion of time-serial data into equiprobable symbols. A second improvement is a method to maximize the channel-consistent total-true rate of forewarning from a plurality of data channels over multiple data sets from the same patient or process. This total-true rate requires resolution of the forewarning indications into true positives, true negatives, false positives and false negatives. A third improvement is the use of various objective functions, as derived from the phase-space dissimilarity measures, to give the best forewarning indication. A fourth improvement uses various search strategies over the phase-space analysis parameters to maximize said objective functions. A fifth improvement shows the usefulness of the method for various biomedical and machine applications.

  19. Measuring Range Anxiety: the Substitution-Emergency-Detour (SED) Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Zhenhong

    Range anxiety has been widely recognized as a critical barrier for battery electric vehicles (BEV), but its measurement method is lacking. Such a knowledge gap makes it difficult to analyse the competiveness of and the demand for BEVs. This study develops the Substitution-Emergency-Detour (SED) method to measure the range anxiety cost, and conducts sensitivity analysis of range anxiety cost with respect to nine factors. It is found that the most effective ways to reduce range anxiety are reducing driving intensity, increasing the vehicle range, extending the vehicle range with better charging infrastructure. Better household vehicle flexibility and less range uncertaintymore » can also significantly reduce range anxiety. The SED method and the numerical results are expected to contribute to better understanding of the range anxiety barrier and the BEV demand.« less

  20. Measuring true Young's modulus of a cantilevered nanowire: effect of clamping on resonance frequency.

    PubMed

    Qin, Qingquan; Xu, Feng; Cao, Yongqing; Ro, Paul I; Zhu, Yong

    2012-08-20

    The effect of clamping on resonance frequency and thus measured Young's modulus of nanowires (NWs) is systematically investigated via a combined experimental and simulation approach. ZnO NWs are used in this work as an example. The resonance tests are performed in situ inside a scanning electron microscope and the NWs are cantilevered on a tungsten probe by electron-beam-induced deposition (EBID) of hydrocarbon. EBID is repeated several times to deposit more hydrocarbons at the same location. The resonance frequency increases with the increasing clamp size until approaching that under the "fixed" boundary condition. The critical clamp size is identified as a function of NW diameter and NW Young's modulus. This work: 1) exemplifies the importance of considering the effect of clamping in measurements of Young's modulus using the resonance method, and 2) demonstrates that the true Young's modulus can be measured if the critical clamp size is reached. Design guidelines on the critical clamp size are provided. Such design guidelines can be extended to other one-dimensional nanostructures such as carbon nanotubes. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Measurement of the main and critical parameters for optimal laser treatment of heart disease

    NASA Astrophysics Data System (ADS)

    Kabeya, FB; Abrahamse, H.; Karsten, AE

    2017-10-01

    Laser light is frequently used in the diagnosis and treatment of patients. As in traditional treatments such as medication, bypass surgery, and minimally invasive ways, laser treatment can also fail and present serious side effects. The true reason for laser treatment failure or the side effects thereof, remains unknown. From the literature review conducted, and experimental results generated we conclude that an optimal laser treatment for coronary artery disease (named heart disease) can be obtained if certain critical parameters are correctly measured and understood. These parameters include the laser power, the laser beam profile, the fluence rate, the treatment time, as well as the absorption and scattering coefficients of the target treatment tissue. Therefore, this paper proposes different, accurate methods for the measurement of these critical parameters to determine the optimal laser treatment of heart disease with a minimal risk of side effects. The results from the measurement of absorption and scattering properties can be used in a computer simulation package to predict the fluence rate. The computing technique is a program based on the random number (Monte Carlo) process and probability statistics to track the propagation of photons through a biological tissue.

  2. Intravenous fluid temperature management by infrared thermometer.

    PubMed

    Lapostolle, Frédéric; Catineau, Jean; Le Toumelin, Philippe; Proust, Clément; Garrigue, Bruno; Galinski, Michel; Adnet, Frédéric

    2006-03-01

    The management of intravenous (IV) fluid temperature is a daily challenge in critical care, anesthesiology, and emergency medicine. Infusion of IV fluids at the right temperature partly influences clinical outcomes of critically ill patients. Nowadays, intravenous fluid temperature is poorly managed, as no suitable device is routinely available. Infrared (IR) thermometers have been recently developed for industrial, personal, or medical purposes. The aim of this study was to evaluate the accuracy of an IR thermometer in measuring temperature of warmed and cooled infusion fluids in fluid bags. This study compared temperatures simultaneously recorded by an infrared thermometer and a temperature sensor. Temperatures of warmed (41 degrees C) and cooled (4 degrees C) infusion fluids in fluid bags were recorded by 2 independent operators every minute until IV bags' temperature reached ambient temperature. The relation curve was established with 576 measures. Temperature measures performed with an IR thermometer were perfectly linear and perfectly correlated with the reference method (R(2) = 0.995, P < 10(-5)). Infrared thermometers are efficient to measure IV fluid bag temperature in the range of temperatures used in clinical practice. As these devices are easy to use and inexpensive, they could be largely used in critical care, anesthesiology, or emergency medicine.

  3. Critical thinking skills in nursing students: comparison of simulation-based performance with metrics

    PubMed Central

    Fero, Laura J.; O’Donnell, John M.; Zullo, Thomas G.; Dabbs, Annette DeVito; Kitutu, Julius; Samosky, Joseph T.; Hoffman, Leslie A.

    2018-01-01

    Aim This paper is a report of an examination of the relationship between metrics of critical thinking skills and performance in simulated clinical scenarios. Background Paper and pencil assessments are commonly used to assess critical thinking but may not reflect simulated performance. Methods In 2007, a convenience sample of 36 nursing students participated in measurement of critical thinking skills and simulation-based performance using videotaped vignettes, high-fidelity human simulation, the California Critical Thinking Disposition Inventory and California Critical Thinking Skills Test. Simulation- based performance was rated as ‘meeting’ or ‘not meeting’ overall expectations. Test scores were categorized as strong, average, or weak. Results Most (75·0%) students did not meet overall performance expectations using videotaped vignettes or high-fidelity human simulation; most difficulty related to problem recognition and reporting findings to the physician. There was no difference between overall performance based on method of assessment (P = 0·277). More students met subcategory expectations for initiating nursing interventions (P ≤ 0·001) using high-fidelity human simulation. The relationship between video-taped vignette performance and critical thinking disposition or skills scores was not statistically significant, except for problem recognition and overall critical thinking skills scores (Cramer’s V = 0·444, P = 0·029). There was a statistically significant relationship between overall high-fidelity human simulation performance and overall critical thinking disposition scores (Cramer’s V = 0·413, P = 0·047). Conclusion Students’ performance reflected difficulty meeting expectations in simulated clinical scenarios. High-fidelity human simulation performance appeared to approximate scores on metrics of critical thinking best. Further research is needed to determine if simulation-based performance correlates with critical thinking skills in the clinical setting. PMID:20636471

  4. Use of Multi-Response Format Test in the Assessment of Medical Students' Critical Thinking Ability.

    PubMed

    Mafinejad, Mahboobeh Khabaz; Arabshahi, Seyyed Kamran Soltani; Monajemi, Alireza; Jalili, Mohammad; Soltani, Akbar; Rasouli, Javad

    2017-09-01

    To evaluate students critical thinking skills effectively, change in assessment practices is must. The assessment of a student's ability to think critically is a constant challenge, and yet there is considerable debate on the best assessment method. There is evidence that the intrinsic nature of open and closed-ended response questions is to measure separate cognitive abilities. To assess critical thinking ability of medical students by using multi-response format of assessment. A cross-sectional study was conducted on a group of 159 undergraduate third-year medical students. All the participants completed the California Critical Thinking Skills Test (CCTST) consisting of 34 multiple-choice questions to measure general critical thinking skills and a researcher-developed test that combines open and closed-ended questions. A researcher-developed 48-question exam, consisting of 8 short-answers and 5 essay questions, 19 Multiple-Choice Questions (MCQ), and 16 True-False (TF) questions, was used to measure critical thinking skills. Correlation analyses were performed using Pearson's coefficient to explore the association between the total scores of tests and subtests. One hundred and fifty-nine students participated in this study. The sample comprised 81 females (51%) and 78 males (49%) with an age range of 20±2.8 years (mean 21.2 years). The response rate was 64.1%. A significant positive correlation was found between types of questions and critical thinking scores, of which the correlations of MCQ (r=0.82) and essay questions (r=0.77) were strongest. The significant positive correlations between multi-response format test and CCTST's subscales were seen in analysis, evaluation, inference and inductive reasoning. Unlike CCTST subscales, multi-response format test have weak correlation with CCTST total score (r=0.45, p=0.06). This study highlights the importance of considering multi-response format test in the assessment of critical thinking abilities of medical students by using both open and closed-ended response questions.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gehin, Jess C; Godfrey, Andrew T; Evans, Thomas M

    The Consortium for Advanced Simulation of Light Water Reactors (CASL) is developing a collection of methods and software products known as VERA, the Virtual Environment for Reactor Applications, including a core simulation capability called VERA-CS. A key milestone for this endeavor is to validate VERA against measurements from operating nuclear power reactors. The first step in validation against plant data is to determine the ability of VERA to accurately simulate the initial startup physics tests for Watts Bar Nuclear Power Station, Unit 1 (WBN1) cycle 1. VERA-CS calculations were performed with the Insilico code developed at ORNL using cross sectionmore » processing from the SCALE system and the transport capabilities within the Denovo transport code using the SPN method. The calculations were performed with ENDF/B-VII.0 cross sections in 252 groups (collapsed to 23 groups for the 3D transport solution). The key results of the comparison of calculations with measurements include initial criticality, control rod worth critical configurations, control rod worth, differential boron worth, and isothermal temperature reactivity coefficient (ITC). The VERA results for these parameters show good agreement with measurements, with the exception of the ITC, which requires additional investigation. Results are also compared to those obtained with Monte Carlo methods and a current industry core simulator.« less

  6. Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine.

    PubMed

    Nguyen, Lee S; Squara, Pierre

    2017-01-01

    Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of accuracy, precision, and step-response change. A great many methods and devices are now used over the world, and this article focuses on several of them, providing with a brief review of related underlying physical principles and validation articles analysis. Reviewed methods include electrical bioimpedance and bioreactance, respiratory-derived cardiac output (CO) monitoring technique, pulse wave transit time, ultrasound CO monitoring, multimodal algorithmic estimation, and inductance thoracocardiography. Quality criteria with which devices were reviewed included: accuracy (closeness of agreement between a measurement value and a true value of the measured), precision (closeness of agreement between replicate measurements on the same or similar objects under specified conditions), and step response change (delay between physiological change and its indication). Our conclusion is that the offer of non-invasive monitoring has improved in the past few years, even though further developments are needed to provide clinicians with sufficiently accurate devices for routine use, as alternative to invasive monitoring devices.

  7. Dose critical in-vivo detection of anti-cancer drug levels in blood

    DOEpatents

    Miller, Holly H.; Hirschfeld, deceased, Tomas B.

    1991-01-01

    A method and apparatus are disclosed for the in vivo and in vitro detection and measurement of dose critical levels of DNA-binding anti-cancer drug levels in biological fluids. The apparatus comprises a laser based fiber optic sensor (optrode) which utilizes the secondary interactions between the drug and an intercalating fluorochrome bound to a probe DNA, which in turn is attached to the fiber tip at one end thereof. The other end of the optical fiber is attached to an illumination source, detector and recorder. The fluorescence intensity is measured as a function of the drug concentration and its binding constant to the probe DNA. Anticancer drugs which lend themselves to analysis by the use of the method and the optrode of the present invention include doxorubicin, daunorubicin, carminomycin, aclacinomycin, chlorambucil, cyclophosphamide, methotrexate, 5-uracil, arabinosyl cytosine, mitomycin, cis-platinum 11 diamine dichloride procarbazine, vinblastine vincristine and the like. The present method and device are suitable for the continuous monitoring of the levels of these and other anticancer drugs in biological fluids such as blood, serum, urine and the like. The optrode of the instant invention also enables the measurement of the levels of these drugs from a remote location and from multiple samples.

  8. PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Stite (IER-148)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rathbone, Bruce A.; Morley, Shannon M.; Stephens, John A.

    The Pacific Northwest National Laboratory (PNNL) participated in a criticality accident dosimetry intercomparison exercise held at the Nevada National Security Site (NNSS) May 24-27, 2016. The exercise was administered by Lawrence Livermore National Laboratory (LLNL) and consisted of three exposures performed using the Godiva-IV critical assembly housed in the Device Assembly Facility (DAF) located on the NNSS site. The exercise allowed participants to test the ability of their nuclear accident dosimeters to meet the performance criteria in ANSI/HPS N13.3-2013, Dosimetry for Criticality Accidents and to obtain new measurement data for use in revising dose calculation methods and quick sort screeningmore » methods where appropriate. PNNL participated with new prototype Personal Nuclear Accident Dosimeter (PNAD) and Fixed Nuclear Accident Dosimeter (FNAD) designs as well as the existing historical PNAD design. The new prototype designs incorporate optically stimulated luminescence (OSL) dosimeters in place of thermoluminescence dosimeters (TLDs), among other design changes, while retaining the same set of activation foils historically used. The default dose calculation methodology established decades ago for use with activation foils in PNNL PNADs and FNADs was used to calculate neutron dose results for both the existing and prototype dosimeters tested in the exercise. The results indicate that the effective cross sections and/or dose conversion factors used historically need to be updated to accurately measure the operational quantities recommended for nuclear accident dosimetry in ANSI/HPS N13.3-2013 and to ensure PNAD and FNAD performance meets the ANSI/HPS N13.3-2013 performance criteria. The operational quantities recommended for nuclear accident dosimetry are personal absorbed dose, Dp(10), and ambient absorbed dose, D*(10).« less

  9. A protocol for the development of a critical thinking assessment tool for nurses using a Delphi technique.

    PubMed

    Jacob, Elisabeth; Duffield, Christine; Jacob, Darren

    2017-08-01

    The aim of this study was to develop an assessment tool to measure the critical thinking ability of nurses. As an increasing number of complex patients are admitted to hospitals, the importance of nurses recognizing changes in health status and picking up on deterioration is more important. To detect early signs of complication requires critical thinking skills. Registered Nurses are expected to commence their clinical careers with the necessary critical thinking skills to ensure safe nursing practice. Currently, there is no published tool to assess critical thinking skills which is context specific to Australian nurses. A modified Delphi study will be used for the project. This study will develop a series of unfolding case scenarios using national health data with multiple-choice questions to assess critical thinking. Face validity of the scenarios will be determined by an expert reference group of clinical and academic nurses. A Delphi study will determine the answers to scenario questions. Panel members will be expert clinicians and educators from two states in Australia. Rasch analysis of the questionnaire will assess validity and reliability of the tool. Funding for the study and Research Ethics Committee approval were obtained in March and November 2016, respectively. Patient outcomes and safety are directly linked to nurses' critical thinking skills. This study will develop an assessment tool to provide a standardized method of measuring nurses' critical thinking skills across Australia. This will provide healthcare providers with greater confidence in the critical thinking level of graduate Registered Nurses. © 2017 John Wiley & Sons Ltd.

  10. Measuring the critical band for speech.

    PubMed

    Healy, Eric W; Bacon, Sid P

    2006-02-01

    The current experiments were designed to measure the frequency resolution employed by listeners during the perception of everyday sentences. Speech bands having nearly vertical filter slopes and narrow bandwidths were sharply partitioned into various numbers of equal log- or ERBN-width subbands. The temporal envelope from each partition was used to amplitude modulate a corresponding band of low-noise noise, and the modulated carriers were combined and presented to normal-hearing listeners. Intelligibility increased and reached asymptote as the number of partitions increased. In the mid- and high-frequency regions of the speech spectrum, the partition bandwidth corresponding to asymptotic performance matched current estimates of psychophysical tuning across a number of conditions. These results indicate that, in these regions, the critical band for speech matches the critical band measured using traditional psychoacoustic methods and nonspeech stimuli. However, in the low-frequency region, partition bandwidths at asymptote were somewhat narrower than would be predicted based upon psychophysical tuning. It is concluded that, overall, current estimates of psychophysical tuning represent reasonably well the ability of listeners to extract spectral detail from running speech.

  11. Identifying the critical point of the weakly first-order itinerant magnet DyCo2 with complementary magnetization and calorimetric measurements

    NASA Astrophysics Data System (ADS)

    Morrison, K.; Dupas, A.; Mudryk, Y.; Pecharsky, V. K.; Gschneidner, K. A.; Caplin, A. D.; Cohen, L. F.

    2013-04-01

    We examine the character of the itinerant magnetic transition of DyCo2 by different calorimetric methods, thereby separating the heat capacity and latent heat contributions to the entropy—allowing direct comparison to other itinerant electron metamagnetic systems. The heat capacity exhibits a large λ-like peak at the ferrimagnetic ordering phase transition, a signature that is remarkably similar to La(Fe,Si)13, where it is attributed to giant spin fluctuations. Using calorimetric measurements, we also determine the point at which the phase transition ceases to be first order: the critical magnetic field, μ0Hcrit = 0.4 ± 0.1 T and temperature Tcrit = 138.5 ± 0.5 K, and we compare these values to those obtained from analysis of magnetization by application of the Shimizu inequality for itinerant electron metamagnetism. Good agreement is found between these independent measurements, thus establishing the phase diagram and critical point with some confidence. In addition, we find that the often-used Banerjee criterion may not be suitable for determination of first order behavior in itinerant magnet systems.

  12. The influence of stem design on critical squeaking friction with ceramic bearings.

    PubMed

    Fan, Na; Morlock, Michael M; Bishop, Nicholas E; Huber, Gerd; Hoffmann, Norbert; Ciavarella, Michele; Chen, Guang X; Hothan, Arne; Witt, Florian

    2013-10-01

    Ceramic-on-ceramic hip joints have been reported to squeak, a phenomenon that may occur in compromised lubrication conditions. One factor related to the incidence of in vivo squeaking is the stem design. However, it has not yet been possible to relate stem design to squeaking in deteriorating lubrication conditions. The purpose of this study was to determine critical friction factors for different stem designs. A hip simulator was used to measure the friction factor of a ceramic bearing with different stem designs and gradually deteriorating lubrication represented by evaporation of a volatile fluid lubricant. The critical squeaking friction factor was measured at the onset of squeaking for each stem. Critical friction was higher for the long cobalt chrome (0.32 ± 0.02) and short titanium stems (0.39 ± 0.02) in comparison with a long titanium stem (0.29 ± 0.02). The onset of squeaking occurred at a friction factor lower than that measured for dry conditions, in which squeaking is usually investigated experimentally. The results suggest that shorter or heavier stems might limit the possibility of squeaking as lubrication deteriorates. The method developed can be used to investigate the influence of design parameters on squeaking probability. Copyright © 2013 Orthopaedic Research Society.

  13. Apparatus and method for critical current measurements

    DOEpatents

    Martin, Joe A.; Dye, Robert C.

    1992-01-01

    An apparatus for the measurement of the critical current of a superconductive sample, e.g., a clad superconductive sample, the apparatus including a conductive coil, a means for maintaining the coil in proximity to a superconductive sample, an electrical connection means for passing a low amplitude alternating current through the coil, a cooling means for maintaining the superconductive sample at a preselected temperature, a means for passing a current through the superconductive sample, and, a means for monitoring reactance of the coil, is disclosed, together with a process of measuring the critical current of a superconductive material, e.g., a clad superconductive material, by placing a superconductive material into the vicinity of the conductive coil of such an apparatus, cooling the superconductive material to a preselected temperature, passing a low amplitude alternating current through the coil, the alternating current capable of generating a magnetic field sufficient to penetrate, e.g., any cladding, and to induce eddy currents in the superconductive material, passing a steadily increasing current through the superconductive material, the current characterized as having a different frequency than the alternating current, and, monitoring the reactance of the coil with a phase sensitive detector as the current passed through the superconductive material is steadily increased whereby critical current of the superconductive material can be observed as the point whereat a component of impedance deviates.

  14. Rational Selection, Criticality Assessment, and Tiering of Quality Attributes and Test Methods for Analytical Similarity Evaluation of Biosimilars.

    PubMed

    Vandekerckhove, Kristof; Seidl, Andreas; Gutka, Hiten; Kumar, Manish; Gratzl, Gyöngyi; Keire, David; Coffey, Todd; Kuehne, Henriette

    2018-05-10

    Leading regulatory agencies recommend biosimilar assessment to proceed in a stepwise fashion, starting with a detailed analytical comparison of the structural and functional properties of the proposed biosimilar and reference product. The degree of analytical similarity determines the degree of residual uncertainty that must be addressed through downstream in vivo studies. Substantive evidence of similarity from comprehensive analytical testing may justify a targeted clinical development plan, and thus enable a shorter path to licensing. The importance of a careful design of the analytical similarity study program therefore should not be underestimated. Designing a state-of-the-art analytical similarity study meeting current regulatory requirements in regions such as the USA and EU requires a methodical approach, consisting of specific steps that far precede the work on the actual analytical study protocol. This white paper discusses scientific and methodological considerations on the process of attribute and test method selection, criticality assessment, and subsequent assignment of analytical measures to US FDA's three tiers of analytical similarity assessment. Case examples of selection of critical quality attributes and analytical methods for similarity exercises are provided to illustrate the practical implementation of the principles discussed.

  15. The use of decision analysis to examine ethical decision making by critical care nurses.

    PubMed

    Hughes, K K; Dvorak, E M

    1997-01-01

    To examine the extent to which critical care staff nurses make ethical decisions that coincide with those recommended by a decision analytic model. Nonexperimental, ex post facto. Midwestern university-affiliated 500 bed tertiary care medical center. One hundred critical care staff nurses randomly selected from seven critical care units. Complete responses were obtained from 82 nurses (for a final response rate of 82%). The dependent variable--consistent decision making--was measured as staff nurses' abilities to make ethical decisions that coincided with those prescribed by the decision model. Subjects completed two instruments, the Ethical Decision Analytic Model, a computer-administered instrument designed to measure staff nurses' abilities to make consistent decisions about a chemically-impaired colleague; and a Background Inventory. The results indicate marked consensus among nurses when informal methods were used. However, there was little consistency between the nurses' informal decisions and those recommended by the decision analytic model. Although 50% (n = 41) of all nurses chose a course of action that coincided with the model's least optimal alternative, few nurses agreed with the model as to the most optimal course of action. The findings also suggest that consistency was unrelated (p > 0.05) to the nurses' educational background or years of clinical experience; that most subjects reported receiving little or no education in decision making during their basic nursing education programs; but that exposure to decision-making strategies was related to years of nursing experience (p < 0.05). The findings differ from related studies that have found a moderate degree of consistency between nurses and decision analytic models for strictly clinical decision tasks, especially when those tasks were less complex. However, the findings partially coincide with other findings that decision analysis may not be particularly well-suited to the critical care environment. Additional research is needed to determine whether critical care nurses use the same decision-making methods as do other nurses; and to clarify the effects of decision task (clinical versus ethical) on nurses' decision making. It should not be assumed that methods used to study nurses' clinical decision making are applicable for all nurses or all types of decisions, including ethical decisions.

  16. Fluorescence correlation spectroscopy analysis for accurate determination of proportion of doubly labeled DNA in fluorescent DNA pool for quantitative biochemical assays.

    PubMed

    Hou, Sen; Sun, Lili; Wieczorek, Stefan A; Kalwarczyk, Tomasz; Kaminski, Tomasz S; Holyst, Robert

    2014-01-15

    Fluorescent double-stranded DNA (dsDNA) molecules labeled at both ends are commonly produced by annealing of complementary single-stranded DNA (ssDNA) molecules, labeled with fluorescent dyes at the same (3' or 5') end. Because the labeling efficiency of ssDNA is smaller than 100%, the resulting dsDNA have two, one or are without a dye. Existing methods are insufficient to measure the percentage of the doubly-labeled dsDNA component in the fluorescent DNA sample and it is even difficult to distinguish the doubly-labeled DNA component from the singly-labeled component. Accurate measurement of the percentage of such doubly labeled dsDNA component is a critical prerequisite for quantitative biochemical measurements, which has puzzled scientists for decades. We established a fluorescence correlation spectroscopy (FCS) system to measure the percentage of doubly labeled dsDNA (PDL) in the total fluorescent dsDNA pool. The method is based on comparative analysis of the given sample and a reference dsDNA sample prepared by adding certain amount of unlabeled ssDNA into the original ssDNA solution. From FCS autocorrelation functions, we obtain the number of fluorescent dsDNA molecules in the focal volume of the confocal microscope and PDL. We also calculate the labeling efficiency of ssDNA. The method requires minimal amount of material. The samples have the concentration of DNA in the nano-molar/L range and the volume of tens of microliters. We verify our method by using restriction enzyme Hind III to cleave the fluorescent dsDNA. The kinetics of the reaction depends strongly on PDL, a critical parameter for quantitative biochemical measurements. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. A high content, high throughput cellular thermal stability assay for measuring drug-target engagement in living cells.

    PubMed

    Massey, Andrew J

    2018-01-01

    Determining and understanding drug target engagement is critical for drug discovery. This can be challenging within living cells as selective readouts are often unavailable. Here we describe a novel method for measuring target engagement in living cells based on the principle of altered protein thermal stabilization / destabilization in response to ligand binding. This assay (HCIF-CETSA) utilizes high content, high throughput single cell immunofluorescent detection to determine target protein levels following heating of adherent cells in a 96 well plate format. We have used target engagement of Chk1 by potent small molecule inhibitors to validate the assay. Target engagement measured by this method was subsequently compared to target engagement measured by two alternative methods (autophosphorylation and CETSA). The HCIF-CETSA method appeared robust and a good correlation in target engagement measured by this method and CETSA for the selective Chk1 inhibitor V158411 was observed. However, these EC50 values were 23- and 12-fold greater than the autophosphorylation IC50. The described method is therefore a valuable advance in the CETSA method allowing the high throughput determination of target engagement in adherent cells.

  18. Near Field HF Antenna Pattern Measurement Method Using an Antenna Pattern Range

    DTIC Science & Technology

    2015-12-01

    Year 2015 by the Applied Electromagnetics Branch (Code 52250) of the System of Systems (SoS) & Platform Design Division (Code 52200), Space and...Head SoS & Platform Design Division iii EXECUTIVE SUMMARY The Antenna Pattern Range (APR) is an essential measurement facility operated at Space...14 1 INTRODUCTION Accurate characterization of antennas designed to support the warfighter is a critical

  19. Measurement of the Infinite Multiplication Constant of Natural Uranium--Graphite Lattices in the RB-1 Critical Assembly by Means of the Zero Reactivity Method. MISURA DELLA COSTANTE DI MOLTIPLICAZIONE INFINITA DI RETICOLI A URANIO NATURALE E GRAFITE NELL'INSIEME CRITICO RB-1 CON IL METODO DELLA REATTIVITA' NULLA (in Italian)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghillardotti, G.

    1966-07-01

    To reduce uncertainties to the minimum, measurements in the RB-1 were conducted on the same materials and with the same instrumentation as those used previously in MARIUS. The values measured in the RB-1, compared with the already known substitution data, are as follows: (a) the difference between the multiplication and the absorption intensity; (b) the fine structure of the flux in the cell; (c) the Pu/U index. The infinite mutiplication factor K{sub infinity} is obtained by combining measurements (a) and (b). The results of this research can be summed up as follows: 1. A consistent and complete experimental procedure hasmore » been devised for measuring the K{sub infinity} of natural uranium/graphite lattices by means of the zero reactivity method. The same applies to the procedure for analysis of the experimental data. 2. The error in (K{sub infinity} -- 1) inherent in the measurement can in our opinion be reduced to 2%. This limit was reached in the last experiment on lattices consisting of tubular elements. 3. Agreement proved to be good with the results obtained by the CEA in the critical assembly MARIUS. (auth)« less

  20. [Metabolic control in the critically ill patient an update: hyperglycemia, glucose variability hypoglycemia and relative hypoglycemia].

    PubMed

    Pérez-Calatayud, Ángel Augusto; Guillén-Vidaña, Ariadna; Fraire-Félix, Irving Santiago; Anica-Malagón, Eduardo Daniel; Briones Garduño, Jesús Carlos; Carrillo-Esper, Raúl

    Metabolic changes of glucose in critically ill patients increase morbidity and mortality. The appropriate level of blood glucose has not been established so far and should be adjusted for different populations. However concepts such as glucose variability and relative hypoglycemia of critically ill patients are concepts that are changing management methods and achieving closer monitoring. The purpose of this review is to present new data about the management and metabolic control of patients in critical areas. Currently glucose can no longer be regarded as an innocent element in critical patients; both hyperglycemia and hypoglycemia increase morbidity and mortality of patients. Protocols and better instruments for continuous measurement are necessary to achieve the metabolic control of our patients. Copyright © 2016 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  1. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    PubMed Central

    Prasser, Christopher; Bele, Sylvia; Keyl, Cornelius; Schweiger, Stefan; Trabold, Benedikt; Amann, Matthias; Welnhofer, Julia; Wiesenack, Christoph

    2007-01-01

    Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC) and percentage changes in COAP (ΔCOAP) for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p < 0.01), while the correlation coefficient between ΔCOPAC and ΔCOAP was 0.46 (p < 0.01). Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03) failed to demonstrate an acceptable accuracy in comparison to the clinical standard of cardiac output determination. PMID:17996086

  2. HYGIENE PRACTICES IN URBAN RESTAURANTS AND CHALLENGES TO IMPLEMENTING FOOD SAFETY AND HAZARD ANALYSIS CRITICAL CONTROL POINTS (HACCP) PROGRAMMES IN THIKA TOWN, KENYA.

    PubMed

    Muinde, R K; Kiinyukia, C; Rombo, G O; Muoki, M A

    2012-12-01

    To determine the microbial load in food, examination of safety measures and possibility of implementing an Hazard Analysis Critical Control Points (HACCP) system. The target population for this study consisted of restaurants owners in Thika. Municipality (n = 30). Simple randomsamples of restaurantswere selected on a systematic sampling method of microbial analysis in cooked, non-cooked, raw food and water sanitation in the selected restaurants. Two hundred and ninety eight restaurants within Thika Municipality were selected. Of these, 30 were sampled for microbiological testing. From the study, 221 (74%) of the restaurants were ready to eat establishments where food was prepared early enough to hold and only 77(26%) of the total restaurants, customers made an order of food they wanted. 118(63%) of the restaurant operators/staff had knowledge on quality control on food safety measures, 24 (8%) of the restaurants applied these knowledge while 256 (86%) of the restaurants staff showed that food contains ingredients that were hazard if poorly handled. 238 (80%) of the resultants used weighing and sorting of food materials, 45 (15%) used preservation methods and the rest used dry foods as critical control points on food safety measures. The study showed that there was need for implementation of Hazard Analysis Critical Control Points (HACCP) system to enhance food safety. Knowledge of HACCP was very low with 89 (30%) of the restaurants applying some of quality measures to the food production process systems. There was contamination with Coliforms, Escherichia coli and Staphylococcus aureus microbial though at very low level. The means of Coliforms, Escherichia coli and Staphylococcus aureas microbial in sampled food were 9.7 x 103CFU/gm, 8.2 x 103 CFU/gm and 5.4 x 103 CFU/gm respectively with Coliforms taking the highest mean.

  3. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    PubMed Central

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed. PMID:18394183

  4. Quantitative operando visualization of the energy band depth profile in solar cells.

    PubMed

    Chen, Qi; Mao, Lin; Li, Yaowen; Kong, Tao; Wu, Na; Ma, Changqi; Bai, Sai; Jin, Yizheng; Wu, Dan; Lu, Wei; Wang, Bing; Chen, Liwei

    2015-07-13

    The energy band alignment in solar cell devices is critically important because it largely governs elementary photovoltaic processes, such as the generation, separation, transport, recombination and collection of charge carriers. Despite the expenditure of considerable effort, the measurement of energy band depth profiles across multiple layers has been extremely challenging, especially for operando devices. Here we present direct visualization of the surface potential depth profile over the cross-sections of operando organic photovoltaic devices using scanning Kelvin probe microscopy. The convolution effect due to finite tip size and cantilever beam crosstalk has previously prohibited quantitative interpretation of scanning Kelvin probe microscopy-measured surface potential depth profiles. We develop a bias voltage-compensation method to address this critical problem and obtain quantitatively accurate measurements of the open-circuit voltage, built-in potential and electrode potential difference.

  5. Quantitative operando visualization of the energy band depth profile in solar cells

    PubMed Central

    Chen, Qi; Mao, Lin; Li, Yaowen; Kong, Tao; Wu, Na; Ma, Changqi; Bai, Sai; Jin, Yizheng; Wu, Dan; Lu, Wei; Wang, Bing; Chen, Liwei

    2015-01-01

    The energy band alignment in solar cell devices is critically important because it largely governs elementary photovoltaic processes, such as the generation, separation, transport, recombination and collection of charge carriers. Despite the expenditure of considerable effort, the measurement of energy band depth profiles across multiple layers has been extremely challenging, especially for operando devices. Here we present direct visualization of the surface potential depth profile over the cross-sections of operando organic photovoltaic devices using scanning Kelvin probe microscopy. The convolution effect due to finite tip size and cantilever beam crosstalk has previously prohibited quantitative interpretation of scanning Kelvin probe microscopy-measured surface potential depth profiles. We develop a bias voltage-compensation method to address this critical problem and obtain quantitatively accurate measurements of the open-circuit voltage, built-in potential and electrode potential difference. PMID:26166580

  6. Bayesian methodology for the design and interpretation of clinical trials in critical care medicine: a primer for clinicians.

    PubMed

    Kalil, Andre C; Sun, Junfeng

    2014-10-01

    To review Bayesian methodology and its utility to clinical decision making and research in the critical care field. Clinical, epidemiological, and biostatistical studies on Bayesian methods in PubMed and Embase from their inception to December 2013. Bayesian methods have been extensively used by a wide range of scientific fields, including astronomy, engineering, chemistry, genetics, physics, geology, paleontology, climatology, cryptography, linguistics, ecology, and computational sciences. The application of medical knowledge in clinical research is analogous to the application of medical knowledge in clinical practice. Bedside physicians have to make most diagnostic and treatment decisions on critically ill patients every day without clear-cut evidence-based medicine (more subjective than objective evidence). Similarly, clinical researchers have to make most decisions about trial design with limited available data. Bayesian methodology allows both subjective and objective aspects of knowledge to be formally measured and transparently incorporated into the design, execution, and interpretation of clinical trials. In addition, various degrees of knowledge and several hypotheses can be tested at the same time in a single clinical trial without the risk of multiplicity. Notably, the Bayesian technology is naturally suited for the interpretation of clinical trial findings for the individualized care of critically ill patients and for the optimization of public health policies. We propose that the application of the versatile Bayesian methodology in conjunction with the conventional statistical methods is not only ripe for actual use in critical care clinical research but it is also a necessary step to maximize the performance of clinical trials and its translation to the practice of critical care medicine.

  7. Methods to measure target site penetration of antibiotics in critically ill patients.

    PubMed

    Schwameis, Richard; Zeitlinger, Markus

    2013-02-01

    While several tools are necessary to repair a car, the engineer knows exactly which instrument he has to utilize at different parts of the broken machine. Likewise, depending on the information we are interested in, we have to choose different tools to investigate and consecutively understand the multiple aspects that are involved in pharmacokinetics of antimicrobial agents in critically ill patients. Some techniques, like blood sampling, microdialysis or positrons emission tomography (PET) will allow for obtaining continues concentration time profiles while others like bronchoalveolar lavage (BAL), biopsy or surgical tissue samples can only be used a limited number of times per subject. PET and methods based on tissue homogenization will deliver an average of the actual concentrations in intra - and extracellular compartments while investigations in isolated blood cells or microdialysis allow for more distinguished allocation of a concentration to a defined compartment. The present review aims at discussing the advantages and disadvantages of the various methods used for assessing pharmacokinetics in critically ill patients with regard to specific aspects of pharmacokinetic research and further reviews data of selected antibiotics as examples for applications of the individual techniques.

  8. Overlapping Modularity at the Critical Point of k-Clique Percolation

    NASA Astrophysics Data System (ADS)

    Tóth, Bálint; Vicsek, Tamás; Palla, Gergely

    2013-05-01

    One of the most remarkable social phenomena is the formation of communities in social networks corresponding to families, friendship circles, work teams, etc. Since people usually belong to several different communities at the same time, the induced overlaps result in an extremely complicated web of the communities themselves. Thus, uncovering the intricate community structure of social networks is a non-trivial task with great potential for practical applications, gaining a notable interest in the recent years. The Clique Percolation Method (CPM) is one of the earliest overlapping community finding methods, which was already used in the analysis of several different social networks. In this approach the communities correspond to k-clique percolation clusters, and the general heuristic for setting the parameters of the method is to tune the system just below the critical point of k-clique percolation. However, this rule is based on simple physical principles and its validity was never subject to quantitative analysis. Here we examine the quality of the partitioning in the vicinity of the critical point using recently introduced overlapping modularity measures. According to our results on real social and other networks, the overlapping modularities show a maximum close to the critical point, justifying the original criteria for the optimal parameter settings.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marshall, William BJ J; Rearden, Bradley T

    The validation of neutron transport methods used in nuclear criticality safety analyses is required by consensus American National Standards Institute/American Nuclear Society (ANSI/ANS) standards. In the last decade, there has been an increased interest in correlations among critical experiments used in validation that have shared physical attributes and which impact the independence of each measurement. The statistical methods included in many of the frequently cited guidance documents on performing validation calculations incorporate the assumption that all individual measurements are independent, so little guidance is available to practitioners on the topic. Typical guidance includes recommendations to select experiments from multiple facilitiesmore » and experiment series in an attempt to minimize the impact of correlations or common-cause errors in experiments. Recent efforts have been made both to determine the magnitude of such correlations between experiments and to develop and apply methods for adjusting the bias and bias uncertainty to account for the correlations. This paper describes recent work performed at Oak Ridge National Laboratory using the Sampler sequence from the SCALE code system to develop experimental correlations using a Monte Carlo sampling technique. Sampler will be available for the first time with the release of SCALE 6.2, and a brief introduction to the methods used to calculate experiment correlations within this new sequence is presented in this paper. Techniques to utilize these correlations in the establishment of upper subcritical limits are the subject of a companion paper and will not be discussed here. Example experimental uncertainties and correlation coefficients are presented for a variety of low-enriched uranium water-moderated lattice experiments selected for use in a benchmark exercise by the Working Party on Nuclear Criticality Safety Subgroup on Uncertainty Analysis in Criticality Safety Analyses. The results include studies on the effect of fuel rod pitch on the correlations, and some observations are also made regarding difficulties in determining experimental correlations using the Monte Carlo sampling technique.« less

  10. Tracking Subpixel Targets with Critically Sampled Optical Sensors

    DTIC Science & Technology

    2012-09-01

    5 [32]. The Viterbi algorithm is a dynamic programming method for calculating the MAP in O(tn2) time . The most common use of this algorithm is in the... method to detect subpixel point targets using the sensor’s PSF as an identifying characteristic. Using matched filtering theory, a measure is defined to...ocean surface beneath the cloud will have a different distribution. While the basic methods will adapt to changes in cloud cover over time , it is also

  11. Absorption of p,p'-dichlorodiphenyldichloroethylene and dieldrin in largemouth bass from a 60-D slow-release pellet and detection using a novel enzyme-linked immunosorbent assay method for blood plasma

    USGS Publications Warehouse

    Muller, Jennifer K.; Sepulveda, Maria S.; Borgert, Christopher J.; Gross, Timothy S.

    2005-01-01

    This work describes the uptake of two organochlorine pesticides from slow-release pellets by largemouth bass and the utility of a blood plasma enzyme-linked immunosorbent assay (ELISA) method for exposure verification. We measured blood and tissue levels by gas chromatography/mass spectrometry and by a novel ELISA method, and present a critical comparison of the results.

  12. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers.

    PubMed

    Haftka, Joris J-H; Scherpenisse, Peter; Oetter, Günter; Hodges, Geoff; Eadsforth, Charles V; Kotthoff, Matthias; Hermens, Joop L M

    2016-09-01

    The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibers were used in the present study to measure CMC values of 12 nonionic, anionic, cationic, and zwitterionic surfactants. The SPME-derived CMC values were compared to values determined using a traditional surface tension method. At the CMC of a surfactant, a break in the relationship between the concentration in SPME fibers and the concentration in water is observed. The CMC values determined with SPME fibers deviated by less than a factor of 3 from values determined with a surface tension method for 7 out of 12 compounds. In addition, the fiber-water sorption isotherms gave information about the sorption mechanism to polyacrylate-coated SPME fibers. A limitation of the SPME method is that CMCs for very hydrophobic cationic surfactants cannot be determined when the cation exchange capacity of the SPME fibers is lower than the CMC value. The advantage of the SPME method over other methods is that CMC values of individual compounds in a mixture can be determined with this method. However, CMC values may be affected by the presence of compounds with other chain lengths in the mixture because of possible mixed micelle formation. Environ Toxicol Chem 2016;35:2173-2181. © 2016 SETAC. © 2016 SETAC.

  13. Methods and techniques for measuring gas emissions from agricultural and animal feeding operations.

    PubMed

    Hu, Enzhu; Babcock, Esther L; Bialkowski, Stephen E; Jones, Scott B; Tuller, Markus

    2014-01-01

    Emissions of gases from agricultural and animal feeding operations contribute to climate change, produce odors, degrade sensitive ecosystems, and pose a threat to public health. The complexity of processes and environmental variables affecting these emissions complicate accurate and reliable quantification of gas fluxes and production rates. Although a plethora of measurement technologies exist, each method has its limitations that exacerbate accurate quantification of gas fluxes. Despite a growing interest in gas emission measurements, only a few available technologies include real-time, continuous monitoring capabilities. Commonly applied state-of-the-art measurement frameworks and technologies were critically examined and discussed, and recommendations for future research to address real-time monitoring requirements for forthcoming regulation and management needs are provided.

  14. Venous Small Bowel Infarction: Intraoperative Laser Doppler Flowmetry Discriminates Critical Blood Supply and Spares Bowel Length

    PubMed Central

    Käser, S. A.; Glauser, P. M.; Maurer, C. A.

    2012-01-01

    Introduction. In mesenteric infarction due to arterial occlusion, laser Doppler flowmetry and spectrometry are known reliable noninvasive methods for measuring microvascular blood flow and oxygen utilisation. Case Presentation. As an innovation we used these methods in a patient with acute extensive mesenteric infarction due to venous occlusion, occurring after radical right hemicolectomy. Aiming to avoid short bowel syndrome, we spared additional 110 cm of small bowel, instead of leaving only 80 centimetres of clinically viable small bowel in situ. The pathological examination showed only 5 mm of vital mucosa to be left distal to the dissection margin. No further interventions were necessary. Conclusion. Laser doppler flowmetry and spectrometry are potentially powerful methods to assist the surgeon's decision-making in critical venous mesenteric perfusion, thus having an important impact on clinical outcome. PMID:23093968

  15. Direct optical band gap measurement in polycrystalline semiconductors: A critical look at the Tauc method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dolgonos, Alex; Mason, Thomas O.; Poeppelmeier, Kenneth R., E-mail: krp@northwestern.edu

    2016-08-15

    The direct optical band gap of semiconductors is traditionally measured by extrapolating the linear region of the square of the absorption curve to the x-axis, and a variation of this method, developed by Tauc, has also been widely used. The application of the Tauc method to crystalline materials is rooted in misconception–and traditional linear extrapolation methods are inappropriate for use on degenerate semiconductors, where the occupation of conduction band energy states cannot be ignored. A new method is proposed for extracting a direct optical band gap from absorption spectra of degenerately-doped bulk semiconductors. This method was applied to pseudo-absorption spectramore » of Sn-doped In{sub 2}O{sub 3} (ITO)—converted from diffuse-reflectance measurements on bulk specimens. The results of this analysis were corroborated by room-temperature photoluminescence excitation measurements, which yielded values of optical band gap and Burstein–Moss shift that are consistent with previous studies on In{sub 2}O{sub 3} single crystals and thin films. - Highlights: • The Tauc method of band gap measurement is re-evaluated for crystalline materials. • Graphical method proposed for extracting optical band gaps from absorption spectra. • The proposed method incorporates an energy broadening term for energy transitions. • Values for ITO were self-consistent between two different measurement methods.« less

  16. The effectiveness of concept mapping on development of critical thinking in nursing education: A systematic review and meta-analysis.

    PubMed

    Yue, Meng; Zhang, Meng; Zhang, Chunmei; Jin, Changde

    2017-05-01

    As an essential skill in daily clinical nursing practice, critical thinking ability has been an important objective in nursing education. Concept mapping enables nursing students connect new information to existing knowledge and integrates interdisciplinary knowledge. However, there is a lack of evidence related to critical thinking ability and concept mapping in nursing education. The purpose of this systematic review and meta-analysis was to assess the effect of concept mapping in developing critical thinking in nursing education. This systematic review was reported in line with Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA). A search was conducted in PubMed, Web of science, Embase, Cochrane Central Register of Controlled Trials (CENTRAL), Cumulative Index to Nursing and Allied Health (CINAHL) and China National Knowledge Infrastructure (CNKI). Randomized controlled trials (RCT) comparing concept mapping and traditional teaching method were retrieved. Data were collected by two reviewers according to the data extraction tables. The methodological quality of included studies was assessed by other two reviewers. The results of meta-analysis were presented using mean difference (MD). Thirteen trials were summarized in the systematic review and eleven trials were included in the meta-analysis. The pooled effect size showed that, comparing with traditional methods, concept mapping could improve subjects' critical thinking ability measured by California Critical Thinking Disposition Inventory (CCTDI), California Critical Thinking Skill Test (CCTST) and Critical Thinking Scale (CTS). The subgroup analyses showed that concept mapping improved the score of all subscales. The result of this review indicated that concept mapping could affect the critical thinking affective dispositions and critical thinking cognitive skills. Further high quality research using uniform evaluation is required. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor,Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2007-01-01

    This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

  18. Coding Classroom Interactions for Collective and Individual Engagement

    ERIC Educational Resources Information Center

    Ryu, Suna; Lombardi, Doug

    2015-01-01

    This article characterizes "engagement in science learning" from a sociocultural perspective and offers a mixed method approach to measuring engagement that combines critical discourse analysis (CDA) and social network analysis (SNA). Conceptualizing engagement from a sociocultural perspective, the article discusses the advantages of a…

  19. FIELD AND LABORATORY PERFORMANCE CHARACTERISTICS OF A NEW SAMPLING PROTOCOL FOR RIVERINE MACROINVERTEBRATE ASSEMBLAGES

    EPA Science Inventory

    Measurement and estimation of performance characteristics (i.e., precision, bias, performance range, interferences and sensitivity) are often neglected in the development and use of new biological sampling methods. However, knowledge of this information is critical in enabling p...

  20. Reference-free, high-resolution measurement method of timing jitter spectra of optical frequency combs

    PubMed Central

    Kwon, Dohyeon; Jeon, Chan-Gi; Shin, Junho; Heo, Myoung-Sun; Park, Sang Eon; Song, Youjian; Kim, Jungwon

    2017-01-01

    Timing jitter is one of the most important properties of femtosecond mode-locked lasers and optical frequency combs. Accurate measurement of timing jitter power spectral density (PSD) is a critical prerequisite for optimizing overall noise performance and further advancing comb applications both in the time and frequency domains. Commonly used jitter measurement methods require a reference mode-locked laser with timing jitter similar to or lower than that of the laser-under-test, which is a demanding requirement for many laser laboratories, and/or have limited measurement resolution. Here we show a high-resolution and reference-source-free measurement method of timing jitter spectra of optical frequency combs using an optical fibre delay line and optical carrier interference. The demonstrated method works well for both mode-locked oscillators and supercontinua, with 2 × 10−9 fs2/Hz (equivalent to −174 dBc/Hz at 10-GHz carrier frequency) measurement noise floor. The demonstrated method can serve as a simple and powerful characterization tool for timing jitter PSDs of various comb sources including mode-locked oscillators, supercontinua and recently emerging Kerr-frequency combs; the jitter measurement results enabled by our method will provide new insights for understanding and optimizing timing noise in such comb sources. PMID:28102352

  1. Claimed effects, outcome variables and methods of measurement for health claims on foods related to the gastrointestinal tract proposed under regulation (EC) 1924/2006.

    PubMed

    Biasini, Beatrice; Marchi, Laura; Angelino, Donato; Bedogni, Giorgio; Zavaroni, Ivana; Pruneti, Carlo; Galli, Daniela; Mirandola, Prisco; Vitale, Marco; Dei Cas, Alessandra; Bonadonna, Riccardo C; Passeri, Giovanni; Ventura, Marco; Del Rio, Daniele; Martini, Daniela

    2018-01-29

    Most of the requests of authorisation to the use of health claims pursuant to Regulation EC 1924/2006 related to the gastrointestinal (GI) tract have received a negative opinion by the European Food Safety Authority (EFSA), mainly because of an insufficient substantiation of the claimed effect (CE). The present manuscript refers to the collection, collation and critical analysis of outcome variables (OVs) and methods of measurement (MMs) related to the GI tract compliant with Regulation 1924/2006. The critical evaluation of OVs and MMs was based on the literature review, with the final aim of defining their appropriateness in the context of a specific CE. The results obtained are relevant for the choice of the best OVs and MMs to be used in randomised controlled trials aimed to substantiate the claims on the GI tract. Moreover, the results can be used by EFSA for updating the guidance for the scientific requirements of such health claims.

  2. Fish measurement using Android smart phone: the example of swamp eel

    NASA Astrophysics Data System (ADS)

    Chen, Baisong; Fu, Zhuo; Ouyang, Haiying; Sun, Yingze; Ge, Changshui; Hu, Jing

    The body length and weight are critical physiological parameters for fishes, especially eel-like fishes like swamp eel(Monopterusalbus).Fast and accurate measuring of body length is significant for swamp eel culturing as well as its resource investigation and protection. This paper presents an Android smart phone-based photogrammetry technology for measuring and estimating the length and weight of swamp eel. This method utilizes the feature that the ratio of lengths of two objects within an image is equal to that of in reality to measure the length of swamp eels. And then, it estimates the weight via a pre-built length-weight regression model. Analysis and experimental results have indicated that this method is a fast and accurate method for length and weight measurements of swamp eel. The cross-validation results shows that the RMSE (root-mean-square error) of total length measurement of swamp eel is0.4 cm, and the RMSE of weight estimation is 11 grams.

  3. Increasing critical sensitivity of the Load/Unload Response Ratio before large earthquakes with identified stress accumulation pattern

    NASA Astrophysics Data System (ADS)

    Yu, Huai-zhong; Shen, Zheng-kang; Wan, Yong-ge; Zhu, Qing-yong; Yin, Xiang-chu

    2006-12-01

    The Load/Unload Response Ratio (LURR) method is proposed for short-to-intermediate-term earthquake prediction [Yin, X.C., Chen, X.Z., Song, Z.P., Yin, C., 1995. A New Approach to Earthquake Prediction — The Load/Unload Response Ratio (LURR) Theory, Pure Appl. Geophys., 145, 701-715]. This method is based on measuring the ratio between Benioff strains released during the time periods of loading and unloading, corresponding to the Coulomb Failure Stress change induced by Earth tides on optimally oriented faults. According to the method, the LURR time series usually climb to an anomalously high peak prior to occurrence of a large earthquake. Previous studies have indicated that the size of critical seismogenic region selected for LURR measurements has great influence on the evaluation of LURR. In this study, we replace the circular region usually adopted in LURR practice with an area within which the tectonic stress change would mostly affect the Coulomb stress on a potential seismogenic fault of a future event. The Coulomb stress change before a hypothetical earthquake is calculated based on a simple back-slip dislocation model of the event. This new algorithm, by combining the LURR method with our choice of identified area with increased Coulomb stress, is devised to improve the sensitivity of LURR to measure criticality of stress accumulation before a large earthquake. Retrospective tests of this algorithm on four large earthquakes occurred in California over the last two decades show remarkable enhancement of the LURR precursory anomalies. For some strong events of lesser magnitudes occurred in the same neighborhoods and during the same time periods, significant anomalies are found if circular areas are used, and are not found if increased Coulomb stress areas are used for LURR data selection. The unique feature of this algorithm may provide stronger constraints on forecasts of the size and location of future large events.

  4. Effects of ethics education on moral sensitivity of nursing students.

    PubMed

    Yeom, Hye-A; Ahn, Sung-Hee; Kim, Su-Jeong

    2017-09-01

    While nursing ethics education is commonly provided for undergraduate nursing students in most nursing colleges, consensus on the content and teaching modules for these ethics courses have still not been established. This study aimed to examine the effects of nursing ethics education on the moral sensitivity and critical thinking disposition of nursing students in Korea. A one-group pre- and post-test design was used. Moral sensitivity was measured using the Korean version of the Moral Sensitivity Questionnaire. Critical thinking disposition was measured using the Critical Thinking Disposition Questionnaire. Participants and research context: Participants were 70 undergraduate nursing students who were attending a university located in Seoul, Korea. The nursing ethics education was provided 7 times, from September to December 2010, and comprised 90-min sessions each week. Ethical considerations: This study was conducted in accordance with the Human Subject Research Ethics Committee guidelines. After the education, the levels for the patient-oriented care, a sub-domain of moral sensitivity, and inquisitiveness, a sub-domain of critical thinking disposition, significantly improved. There were no changes in overall scores for moral sensitivity and critical thinking disposition. There were significant positive correlations between moral sensitivity and critical thinking disposition both pre- and post-intervention. These results reflect the need for ongoing efforts to develop innovative content, structure, and instructional methods for undergraduate nursing ethics education programs.

  5. The Predictive Prognostic Values of Serum TNF-α in Comparison to SOFA Score Monitoring in Critically Ill Patients

    PubMed Central

    Yousef, Ayman Abd Al-Maksoud; Suliman, Ghada Abdulmomen

    2013-01-01

    Background. The use of inflammatory markers to follow up critically ill patients is controversial. The short time frame, the need for frequent and serial measurement of biomarkers, the presence of soluble receptor and their relatively high cost are the major drawbacks. Our study's objective is to compare the prognostic values of serum TNF-α and SOFA score monitoring in critically ill patients. Patients and Methods. A total of ninety patients were included in the study. Forty-five patients developed septic complication (sepsis group). Forty-five patients were critically ill without evidence of infectious organism (SIRS group). Patients' data include clinical status, central venous pressure, and laboratory analysis were measured. A serum level of TNF-α and SOFA score were monitored. Results. Monitoring of TNF-α revealed significant elevation of TNF-α at 3rd and 5th days of ICU admission in both groups. Monitoring of SOFA score revealed significant elevation of SOFA scores in both groups throughout their ICU stay, particularly in nonsurvivors. Positive predictive ability of SOFA score was demonstrated in critically ill patients. Conclusion. Transient significant increase in serum levels of TNF-α were detected in septic patients. Persistent elevation of SOFA score was detected in nonsurvivor septic patients. SOFA score is an independent prognostic value in critically ill patients. PMID:24175285

  6. Identification of Watershed-scale Critical Source Areas Using Bayesian Maximum Entropy Spatiotemporal Analysis

    NASA Astrophysics Data System (ADS)

    Roostaee, M.; Deng, Z.

    2017-12-01

    The states' environmental agencies are required by The Clean Water Act to assess all waterbodies and evaluate potential sources of impairments. Spatial and temporal distributions of water quality parameters are critical in identifying Critical Source Areas (CSAs). However, due to limitations in monetary resources and a large number of waterbodies, available monitoring stations are typically sparse with intermittent periods of data collection. Hence, scarcity of water quality data is a major obstacle in addressing sources of pollution through management strategies. In this study spatiotemporal Bayesian Maximum Entropy method (BME) is employed to model the inherent temporal and spatial variability of measured water quality indicators such as Dissolved Oxygen (DO) concentration for Turkey Creek Watershed. Turkey Creek is located in northern Louisiana and has been listed in 303(d) list for DO impairment since 2014 in Louisiana Water Quality Inventory Reports due to agricultural practices. BME method is proved to provide more accurate estimates than the methods of purely spatial analysis by incorporating space/time distribution and uncertainty in available measured soft and hard data. This model would be used to estimate DO concentration at unmonitored locations and times and subsequently identifying CSAs. The USDA's crop-specific land cover data layers of the watershed were then used to determine those practices/changes that led to low DO concentration in identified CSAs. Primary results revealed that cultivation of corn and soybean as well as urban runoff are main contributing sources in low dissolved oxygen in Turkey Creek Watershed.

  7. Measurement of the residual stress in hot rolled strip using strain gauge method

    NASA Astrophysics Data System (ADS)

    Kumar, Lokendra; Majumdar, Shrabani; Sahu, Raj Kumar

    2017-07-01

    Measurement of the surface residual stress in a flat hot rolled steel strip using strain gauge method is considered in this paper. Residual stresses arise in the flat strips when the shear cut and laser cut is applied. Bending, twisting, central buckled and edge waviness is the common defects occur during the cutting and uncoiling process. These defects arise due to the non-uniform elastic-plastic deformation, phase transformation occurring during cooling and coiling-uncoiling process. The residual stress analysis is very important because with early detection it is possible to prevent an object from failure. The goal of this paper is to measure the surface residual stress in flat hot rolled strip using strain gauge method. The residual stress was measured in the head and tail end of hot rolled strip considering as a critical part of the strip.

  8. Methods for determining the degree of baking in anodes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hughes, C.P.

    Anode baking temperature is recognized as a critical factor in determining anode quality and performance. It is difficult and costly to measure directly and an indirect method, the coke L{sub c} technique, is often used. In this technique, baking temperature is estimated from the average crystallite size in the c direction (L{sub c}) of a coke sample placed in the anode stubhole. The paper details the results of a large statistically designed experimental program in which coke L{sub c} results were compared to anode properties routinely measured by smelters. Anode thermal conductivity and air and carboxy reactivity were found tomore » correlate well with baking temperature. A direct anode L{sub c} measurement technique was also strongly associated with temperature, particularly at high baking temperatures. Recommendations are given on the usefulness and simplicity of traditional anode property measurements for assessing baking temperatures as alternatives to the coke L{sub c} method.« less

  9. A multi-time-step noise reduction method for measuring velocity statistics from particle tracking velocimetry

    NASA Astrophysics Data System (ADS)

    Machicoane, Nathanaël; López-Caballero, Miguel; Bourgoin, Mickael; Aliseda, Alberto; Volk, Romain

    2017-10-01

    We present a method to improve the accuracy of velocity measurements for fluid flow or particles immersed in it, based on a multi-time-step approach that allows for cancellation of noise in the velocity measurements. Improved velocity statistics, a critical element in turbulent flow measurements, can be computed from the combination of the velocity moments computed using standard particle tracking velocimetry (PTV) or particle image velocimetry (PIV) techniques for data sets that have been collected over different values of time intervals between images. This method produces Eulerian velocity fields and Lagrangian velocity statistics with much lower noise levels compared to standard PIV or PTV measurements, without the need of filtering and/or windowing. Particle displacement between two frames is computed for multiple different time-step values between frames in a canonical experiment of homogeneous isotropic turbulence. The second order velocity structure function of the flow is computed with the new method and compared to results from traditional measurement techniques in the literature. Increased accuracy is also demonstrated by comparing the dissipation rate of turbulent kinetic energy measured from this function against previously validated measurements.

  10. Vertebral rotation measurement: a summary and comparison of common radiographic and CT methods

    PubMed Central

    Lam, Gabrielle C; Hill, Doug L; Le, Lawrence H; Raso, Jim V; Lou, Edmond H

    2008-01-01

    Current research has provided a more comprehensive understanding of Adolescent Idiopathic Scoliosis (AIS) as a three-dimensional spinal deformity, encompassing both lateral and rotational components. Apart from quantifying curve severity using the Cobb angle, vertebral rotation has become increasingly prominent in the study of scoliosis. It demonstrates significance in both preoperative and postoperative assessment, providing better appreciation of the impact of bracing or surgical interventions. In the past, the need for computer resources, digitizers and custom software limited studies of rotation to research performed after a patient left the scoliosis clinic. With advanced technology, however, rotation measurements are now more feasible. While numerous vertebral rotation measurement methods have been developed and tested, thorough comparisons of these are still relatively unexplored. This review discusses the advantages and disadvantages of six common measurement techniques based on technology most pertinent in clinical settings: radiography (Cobb, Nash-Moe, Perdriolle and Stokes' method) and computer tomography (CT) imaging (Aaro-Dahlborn and Ho's method). Better insight into the clinical suitability of rotation measurement methods currently available is presented, along with a discussion of critical concerns that should be addressed in future studies and development of new methods. PMID:18976498

  11. A maintenance time prediction method considering ergonomics through virtual reality simulation.

    PubMed

    Zhou, Dong; Zhou, Xin-Xin; Guo, Zi-Yue; Lv, Chuan

    2016-01-01

    Maintenance time is a critical quantitative index in maintainability prediction. An efficient maintenance time measurement methodology plays an important role in early stage of the maintainability design. While traditional way to measure the maintenance time ignores the differences between line production and maintenance action. This paper proposes a corrective MOD method considering several important ergonomics factors to predict the maintenance time. With the help of the DELMIA analysis tools, the influence coefficient of several factors are discussed to correct the MOD value and the designers can measure maintenance time by calculating the sum of the corrective MOD time of each maintenance therbligs. Finally a case study is introduced, by maintaining the virtual prototype of APU motor starter in DELMIA, designer obtains the actual maintenance time by the proposed method, and the result verifies the effectiveness and accuracy of the proposed method.

  12. Use of a journal club and letter-writing exercise to teach critical appraisal to medical undergraduates.

    PubMed

    Edwards, R; White, M; Gray, J; Fischbacher, C

    2001-07-01

    There is growing interest in methods of teaching critical appraisal skills at undergraduate and postgraduate levels. We describe an approach using a journal club and subsequent letter writing to teach critical appraisal and writing skills to medical undergraduates. The exercise occurs during a 3-week public health medicine attachment in the third year of the undergraduate curriculum. Students work in small groups to appraise a recently published research paper, present their findings to their peers in a journal club, and draft a letter to the journal editor. Evaluation took place through: informal and formal feedback from students; number of letters written, submitted and published, and a comparison of marks obtained by students submitting a literature review assignment with and without critical appraisal teaching during the public health attachment. Feedback from students was overwhelmingly positive. In the first 3(1/2) years, 26 letters have been published or accepted for publication, and 58 letters published on the Internet. There were no significant differences in overall marks or marks for the critical appraisal component of the literature review assignments between the two student groups. We believe our approach is an innovative and enjoyable method for teaching critical appraisal and writing skills to medical students. Lack of difference in marks in the literature review between the student groups may reflect its insensitivity as an outcome measure, contamination by other critical appraisal teaching, or true ineffectiveness.

  13. Critical Seismic Vector Random Excitations for Multiply Supported Structures

    NASA Astrophysics Data System (ADS)

    Sarkar, A.; Manohar, C. S.

    1998-05-01

    A method for determining critical power spectral density matrix models for earthquake excitations which maximize steady response variance of linear multiply supported extended structures and which also satisfy constraints on input variance, zero crossing rates, frequency content and transmission time lag has been developed. The optimization problem is shown to be non-linear in nature and solutions are obtained by using an iterative technique which is based on linear programming method. A constraint on entropy rate as a measure of uncertainty which can be expected in realistic earthquake ground motions is proposed which makes the critical excitations more realistic. Two special cases are also considered. Firstly, when knowledge of autospectral densities is available, the critical response is shown to be produced by fully coherent excitations which are neither in-phase nor out-of-phase. The critical phase between the excitation components depends on structural parameters, but independent of the auto-spectral densities of the excitations. Secondly, when the knowledge of autospectral densities and phase spectrum of the excitations is available, the critical response is shown to be produced by a system dependent coherence function representing neither fully coherent nor fully incoherent ground motions. The applications of these special cases are discussed in the context of land-based extended structures and secondary systems such as nuclear piping assembly. Illustrative examples on critical inputs and response of sdof and a long-span suspended cable which demonstrated the various features of the approach developed are presented.

  14. Reverse engineering the face space: Discovering the critical features for face identification.

    PubMed

    Abudarham, Naphtali; Yovel, Galit

    2016-01-01

    How do we identify people? What are the critical facial features that define an identity and determine whether two faces belong to the same person or different people? To answer these questions, we applied the face space framework, according to which faces are represented as points in a multidimensional feature space, such that face space distances are correlated with perceptual similarities between faces. In particular, we developed a novel method that allowed us to reveal the critical dimensions (i.e., critical features) of the face space. To that end, we constructed a concrete face space, which included 20 facial features of natural face images, and asked human observers to evaluate feature values (e.g., how thick are the lips). Next, we systematically and quantitatively changed facial features, and measured the perceptual effects of these manipulations. We found that critical features were those for which participants have high perceptual sensitivity (PS) for detecting differences across identities (e.g., which of two faces has thicker lips). Furthermore, these high PS features vary minimally across different views of the same identity, suggesting high PS features support face recognition across different images of the same face. The methods described here set an infrastructure for discovering the critical features of other face categories not studied here (e.g., Asians, familiar) as well as other aspects of face processing, such as attractiveness or trait inferences.

  15. Measuring the Indonesian provinces competitiveness by using PCA technique

    NASA Astrophysics Data System (ADS)

    Runita, Ditha; Fajriyah, Rohmatul

    2017-12-01

    Indonesia is a country which has vast teritoty. It has 34 provinces. Building local competitiveness is critical to enhance the long-term national competitiveness especially for a country as diverse as Indonesia. A competitive local government can attract and maintain successful firms and increase living standards for its inhabitants, because investment and skilled workers gravitate from uncompetitive regions to more competitive ones. Altough there are other methods to measuring competitiveness, but here we have demonstrated a simple method using principal component analysis (PCA). It can directly be applied to correlated, multivariate data. The analysis on Indonesian provinces provides 3 clusters based on the competitiveness measurement and the clusters are Bad, Good and Best perform provinces.

  16. Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing.

    PubMed

    Ling, Xue; Wang, Yusheng; Li, Xide

    2014-10-01

    An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li-Etsion-Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.

  17. Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing

    NASA Astrophysics Data System (ADS)

    Ling, Xue; Wang, Yusheng; Li, Xide

    2014-10-01

    An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li-Etsion-Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.

  18. Comparison of Quantitative Wall Motion Analysis and Strain For Detection Of Coronary Stenosis With Three-Dimensional Dobutamine Stress Echocardiography

    PubMed Central

    Parker, Katherine M.; Clark, Alexander P.; Goodman, Norman C.; Glover, David K.; Holmes, Jeffrey W.

    2015-01-01

    Background Quantitative analysis of wall motion from three-dimensional (3D) dobutamine stress echocardiography (DSE) could provide additional diagnostic information not available from qualitative analysis. In this study we compare the effectiveness of 3D fractional shortening (3DFS), a measure of wall motion computed from 3D echocardiography (3DE), to strain and strain rate measured with sonomicrometry for detecting critical stenoses during DSE. Methods Eleven open-chest dogs underwent DSE both with and without a critical stenosis. 3DFS was measured from 3DE images acquired at peak stress. 3DFS was normalized by subtracting average 3DFS during control peak stress (Δ3DFS). Strains in the perfusion defect (PD) were measured from sonomicrometry, and PD size and location were measured with microspheres. Results A Δ3DFS abnormality indicated the presence of a critical stenosis with high sensitivity and specificity (88% and 100%, respectively), and Δ3DFS abnormality size correlated with PD size (R2=0.54). The sensitivity and specificity for Δ3DFS was similar to that for area strain (88%, 100%) and circumferential strain and strain rate (88%, 92% and 88%, 86%, respectively), while longitudinal strain and strain rate were less specific. Δ3DFS correlated significantly with both coronary flow reserve (R2=0.71) and PD size (R2=0.97), while area strain correlated with PD size only (R2=0.67), and other measures were not significantly correlated with flow reserve or PD size. Conclusion Quantitative wall motion analysis using Δ3DFS is effective for detecting critical stenoses during DSE, performing similarly to 3D strain, and provides potentially useful information on the size and location of a perfusion defect. PMID:24815588

  19. Internal Stress Monitoring of In-Service Structural Steel Members with Ultrasonic Method

    PubMed Central

    Li, Zuohua; He, Jingbo; Teng, Jun; Wang, Ying

    2016-01-01

    Internal stress in structural steel members is an important parameter for steel structures in their design, construction, and service stages. However, it is hard to measure via traditional approaches. Among the existing non-destructive testing (NDT) methods, the ultrasonic method has received the most research attention. Longitudinal critically refracted (Lcr) waves, which propagate parallel to the surface of the material within an effective depth, have shown great potential as an effective stress measurement approach. This paper presents a systematic non-destructive evaluation method to determine the internal stress in in-service structural steel members using Lcr waves. Based on theory of acoustoelasticity, a stress evaluation formula is derived. Factor of stress to acoustic time difference is used to describe the relationship between stress and measurable acoustic results. A testing facility is developed and used to demonstrate the performance of the proposed method. Two steel members are measured by using the proposed method and the traditional strain gauge method for verification. Parametric studies are performed on three steel members and the aluminum plate to investigate the factors that influence the testing results. The results show that the proposed method is effective and accurate for determining stress in in-service structural steel members. PMID:28773347

  20. Internal Stress Monitoring of In-Service Structural Steel Members with Ultrasonic Method.

    PubMed

    Li, Zuohua; He, Jingbo; Teng, Jun; Wang, Ying

    2016-03-23

    Internal stress in structural steel members is an important parameter for steel structures in their design, construction, and service stages. However, it is hard to measure via traditional approaches. Among the existing non-destructive testing (NDT) methods, the ultrasonic method has received the most research attention. Longitudinal critically refracted (Lcr) waves, which propagate parallel to the surface of the material within an effective depth, have shown great potential as an effective stress measurement approach. This paper presents a systematic non-destructive evaluation method to determine the internal stress in in-service structural steel members using Lcr waves. Based on theory of acoustoelasticity, a stress evaluation formula is derived. Factor of stress to acoustic time difference is used to describe the relationship between stress and measurable acoustic results. A testing facility is developed and used to demonstrate the performance of the proposed method. Two steel members are measured by using the proposed method and the traditional strain gauge method for verification. Parametric studies are performed on three steel members and the aluminum plate to investigate the factors that influence the testing results. The results show that the proposed method is effective and accurate for determining stress in in-service structural steel members.

  1. Novel scanning electron microscope bulge test technique integrated with loading function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Chuanwei; Xie, Huimin, E-mail: liuzw@bit.edu.cn, E-mail: xiehm@mail.tsinghua.edu.cn; Liu, Zhanwei, E-mail: liuzw@bit.edu.cn, E-mail: xiehm@mail.tsinghua.edu.cn

    2014-10-15

    Membranes and film-on-substrate structures are critical elements for some devices in electronics industry and for Micro Electro Mechanical Systems devices. These structures are normally at the scale of micrometer or even nanometer. Thus, the measurement for the mechanical property of these membranes poses a challenge over the conventional measurements at macro-scales. In this study, a novel bulge test method is presented for the evaluation of mechanical property of micro thin membranes. Three aspects are discussed in the study: (a) A novel bulge test with a Scanning Electron Microscope system realizing the function of loading and measuring simultaneously; (b) a simplifiedmore » Digital Image Correlation method for a height measurement; and (c) an imaging distortion correction by the introduction of a scanning Moiré method. Combined with the above techniques, biaxial modulus as well as Young's modulus of the polyimide film can be determined. Besides, a standard tensile test is conducted as an auxiliary experiment to validate the feasibility of the proposed method.« less

  2. [Measuring client satisfaction in youth mental health care: qualitative methods and satisfaction questionnaires].

    PubMed

    Vanderfaeillie, J; Stroobants, T; van West, D; Andries, C

    2015-01-01

    Quality youth care and decisions about youth care should ideally be based on a combination of empirical data, the clinical judgment of health professionals and the views and preferences of clients. Additionally, the treatment provided needs to fit in with the client's social and cultural background. Clients' views about their treatment are often collected via satisfaction measurements and particularly via satisfaction questionnaires. To make a critical analysis of the factors that determine both client satisfaction and the content of the satisfaction questionnaires used as a measurement method in youth care. We made a selective study of the relevant literature. Our results show that client satisfaction is not an indicator of the effectiveness of treatment and that the degree of client satisfaction varies according to the client's outlook and perspective. Apparently, there are many disadvantages of using questionnaires as a measurement method. For the collection of a young person's views, qualitative methods seem to be more effective than questionnaires.

  3. Strategies of experiment standardization and response optimization in a rat model of hemorrhagic shock and chronic hypertension.

    PubMed

    Reynolds, Penny S; Tamariz, Francisco J; Barbee, Robert Wayne

    2010-04-01

    Exploratory pilot studies are crucial to best practice in research but are frequently conducted without a systematic method for maximizing the amount and quality of information obtained. We describe the use of response surface regression models and simultaneous optimization methods to develop a rat model of hemorrhagic shock in the context of chronic hypertension, a clinically relevant comorbidity. Response surface regression model was applied to determine optimal levels of two inputs--dietary NaCl concentration (0.49%, 4%, and 8%) and time on the diet (4, 6, 8 weeks)--to achieve clinically realistic and stable target measures of systolic blood pressure while simultaneously maximizing critical oxygen delivery (a measure of vulnerability to hemorrhagic shock) and body mass M. Simultaneous optimization of the three response variables was performed though a dimensionality reduction strategy involving calculation of a single aggregate measure, the "desirability" function. Optimal conditions for inducing systolic blood pressure of 208 mmHg, critical oxygen delivery of 4.03 mL/min, and M of 290 g were determined to be 4% [NaCl] for 5 weeks. Rats on the 8% diet did not survive past 7 weeks. Response surface regression model and simultaneous optimization method techniques are commonly used in process engineering but have found little application to date in animal pilot studies. These methods will ensure both the scientific and ethical integrity of experimental trials involving animals and provide powerful tools for the development of novel models of clinically interacting comorbidities with shock.

  4. Mean-field behavior as a result of noisy local dynamics in self-organized criticality: Neuroscience implications

    NASA Astrophysics Data System (ADS)

    Moosavi, S. Amin; Montakhab, Afshin

    2014-05-01

    Motivated by recent experiments in neuroscience which indicate that neuronal avalanches exhibit scale invariant behavior similar to self-organized critical systems, we study the role of noisy (nonconservative) local dynamics on the critical behavior of a sandpile model which can be taken to mimic the dynamics of neuronal avalanches. We find that despite the fact that noise breaks the strict local conservation required to attain criticality, our system exhibits true criticality for a wide range of noise in various dimensions, given that conservation is respected on the average. Although the system remains critical, exhibiting finite-size scaling, the value of critical exponents change depending on the intensity of local noise. Interestingly, for a sufficiently strong noise level, the critical exponents approach and saturate at their mean-field values, consistent with empirical measurements of neuronal avalanches. This is confirmed for both two and three dimensional models. However, the addition of noise does not affect the exponents at the upper critical dimension (D =4). In addition to an extensive finite-size scaling analysis of our systems, we also employ a useful time-series analysis method to establish true criticality of noisy systems. Finally, we discuss the implications of our work in neuroscience as well as some implications for the general phenomena of criticality in nonequilibrium systems.

  5. Recommended Practices in Thrust Measurements

    NASA Technical Reports Server (NTRS)

    Polk, James E.; Pancotti, Anthony; Haag, Thomas; King, Scott; Walker, Mitchell; Blakely, Joseph; Ziemer, John

    2013-01-01

    Accurate, direct measurement of thrust or impulse is one of the most critical elements of electric thruster characterization, and one of the most difficult measurements to make. The American Institute of Aeronautics and Astronautics has started an initiative to develop standards for many important measurement processes in electric propulsion, including thrust measurements. This paper summarizes recommended practices for the design, calibration, and operation of pendulum thrust stands, which are widely recognized as the best approach for measuring micro N- to mN-level thrust and micro Ns-level impulse bits. The fundamentals of pendulum thrust stand operation are reviewed, along with its implementation in hanging pendulum, inverted pendulum, and torsional balance configurations. Methods of calibration and recommendations for calibration processes are presented. Sources of error are identified and methods for data processing and uncertainty analysis are discussed. This review is intended to be the first step toward a recommended practices document to help the community produce high quality thrust measurements.

  6. Spiritual Assessment in Counseling: Methods and Practice

    ERIC Educational Resources Information Center

    Oakes, K. Elizabeth; Raphel, Mary M.

    2008-01-01

    Given the widely expanding professional and empirical support for integrating spirituality into counseling, the authors present a practical discussion for raising counselors' general awareness and skill in the critical area of spiritual assessment. A discussion of rationale, measurement, and clinical practice is provided along with case examples.…

  7. STATUS OF RESEARCH ON AIR QUALITY: MERCURY, TRACE ELEMENTS, AND PARTICULATE MATTER. (R827649)

    EPA Science Inventory

    The Air Quality Conference reviewed the state of science and policy on the pollutants mercury, trace elements, and particulate matter (PM) in the environment. Critical issues dealing with impacts on health and ecosystems, emission prevention and control, measurement methods, a...

  8. QUANTITATIVE IN VITRO MEASUREMENT OF CELLULAR PROCESSES CRITICAL TO THE DEVELOPMENT OF NEURAL CONNECTIVITY USING HCA.

    EPA Science Inventory

    New methods are needed to screen thousands of environmental chemicals for toxicity, including developmental neurotoxicity. In vitro, cell-based assays that model key cellular events have been proposed for high throughput screening of chemicals for developmental neurotoxicity. Whi...

  9. Measuring Psychological Critical Thinking: An Update

    ERIC Educational Resources Information Center

    Lawson, Timothy J.; Jordan-Fleming, Mary Kay; Bodle, James H.

    2015-01-01

    Critical thinking is widely considered an important skill for psychology majors. However, few measures exist of the types of critical thinking that are specific to psychology majors. Lawson (1999) designed the Psychological Critical Thinking Exam (PCTE) to measure students' ability to "think critically, or evaluate claims, in a way that…

  10. A computer program for the localization of small areas in roentgenological images

    NASA Technical Reports Server (NTRS)

    Keller, R. A.; Baily, N. A.

    1976-01-01

    A method and associated algorithm are presented which allow a simple and accurate determination to be made of the location of small symmetric areas presented in roentgenological images. The method utilizes an operator to visually spot object positions but eliminates the need for critical positioning accuracy on the operator's part. The rapidity of measurement allows results to be evaluated on-line. Parameters associated with the algorithm have been analyzed, and methods to facilitate an optimum choice for any particular experimental setup are presented.

  11. Astrometric "Core-shifts" at the Highest Frequencies

    NASA Technical Reports Server (NTRS)

    Rioja, Maria; Dodson, Richard

    2010-01-01

    We discuss the application of a new VLBI astrometric method named "Source/Frequency Phase Referencing" to measurements of "core-shifts" in radio sources used for geodetic observations. We detail the reasons that astrometrical observations of 'core-shifts' have become critical in the era of VLBI2010. We detail how this new method allows the problem to be addressed at the highest frequencies and outline its superior compensation of tropospheric errors.

  12. Estimating carbon and nitrogen pools in a forest soil: Influence of soil bulk density methods and rock content

    Treesearch

    Martin F. Jurgensen; Deborah S. Page-Dumroese; Robert E. Brown; Joanne M. Tirocke; Chris A. Miller; James B. Pickens; Min Wang

    2017-01-01

    Soils with high rock content are common in many US forests, and contain large amounts of stored C. Accurate measurements of soil bulk density and rock content are critical for calculating and assessing changes in both C and nutrient pool size, but bulk density sampling methods have limitations and sources of variability. Therefore, we evaluated the use of small-...

  13. Segmentation quality evaluation using region-based precision and recall measures for remote sensing images

    NASA Astrophysics Data System (ADS)

    Zhang, Xueliang; Feng, Xuezhi; Xiao, Pengfeng; He, Guangjun; Zhu, Liujun

    2015-04-01

    Segmentation of remote sensing images is a critical step in geographic object-based image analysis. Evaluating the performance of segmentation algorithms is essential to identify effective segmentation methods and optimize their parameters. In this study, we propose region-based precision and recall measures and use them to compare two image partitions for the purpose of evaluating segmentation quality. The two measures are calculated based on region overlapping and presented as a point or a curve in a precision-recall space, which can indicate segmentation quality in both geometric and arithmetic respects. Furthermore, the precision and recall measures are combined by using four different methods. We examine and compare the effectiveness of the combined indicators through geometric illustration, in an effort to reveal segmentation quality clearly and capture the trade-off between the two measures. In the experiments, we adopted the multiresolution segmentation (MRS) method for evaluation. The proposed measures are compared with four existing discrepancy measures to further confirm their capabilities. Finally, we suggest using a combination of the region-based precision-recall curve and the F-measure for supervised segmentation evaluation.

  14. Clinically Practical Approach for Screening of Low Muscularity Using Electronic Linear Measures on Computed Tomography Images in Critically Ill Patients.

    PubMed

    Avrutin, Egor; Moisey, Lesley L; Zhang, Roselyn; Khattab, Jenna; Todd, Emma; Premji, Tahira; Kozar, Rosemary; Heyland, Daren K; Mourtzakis, Marina

    2017-12-06

    Computed tomography (CT) scans performed during routine hospital care offer the opportunity to quantify skeletal muscle and predict mortality and morbidity in intensive care unit (ICU) patients. Existing methods of muscle cross-sectional area (CSA) quantification require specialized software, training, and time commitment that may not be feasible in a clinical setting. In this article, we explore a new screening method to identify patients with low muscle mass. We analyzed 145 scans of elderly ICU patients (≥65 years old) using a combination of measures obtained with a digital ruler, commonly found on hospital radiological software. The psoas and paraspinal muscle groups at the level of the third lumbar vertebra (L3) were evaluated by using 2 linear measures each and compared with an established method of CT image analysis of total muscle CSA in the L3 region. There was a strong association between linear measures of psoas and paraspinal muscle groups and total L3 muscle CSA (R 2 = 0.745, P < 0.001). Linear measures, age, and sex were included as covariates in a multiple logistic regression to predict those with low muscle mass; receiver operating characteristic (ROC) area under the curve (AUC) of the combined psoas and paraspinal linear index model was 0.920. Intraclass correlation coefficients (ICCs) were used to evaluate intrarater and interrater reliability, resulting in scores of 0.979 (95% CI: 0.940-0.992) and 0.937 (95% CI: 0.828-0.978), respectively. A digital ruler can reliably predict L3 muscle CSA, and these linear measures may be used to identify critically ill patients with low muscularity who are at risk for worse clinical outcomes. © 2017 American Society for Parenteral and Enteral Nutrition.

  15. Simultaneous overlay and CD measurement for double patterning: scatterometry and RCWA approach

    NASA Astrophysics Data System (ADS)

    Li, Jie; Liu, Zhuan; Rabello, Silvio; Dasari, Prasad; Kritsun, Oleg; Volkman, Catherine; Park, Jungchul; Singh, Lovejeet

    2009-03-01

    As optical lithography advances to 32 nm technology node and beyond, double patterning technology (DPT) has emerged as an attractive solution to circumvent the fundamental optical limitations. DPT poses unique demands on critical dimension (CD) uniformity and overlay control, making the tolerance decrease much faster than the rate at which critical dimension shrinks. This, in turn, makes metrology even more challenging. In the past, multi-pad diffractionbased overlay (DBO) using empirical approach has been shown to be an effective approach to measure overlay error associated with double patterning [1]. In this method, registration errors for double patterning were extracted from specially designed diffraction targets (three or four pads for each direction); CD variation is assumed negligible within each group of adjacent pads and not addressed in the measurement. In another paper, encouraging results were reported with a first attempt at simultaneously extracting overlay and CD parameters using scatterometry [2]. In this work, we apply scatterometry with a rigorous coupled wave analysis (RCWA) approach to characterize two double-patterning processes: litho-etch-litho-etch (LELE) and litho-freeze-litho-etch (LFLE). The advantage of performing rigorous modeling is to reduce the number of pads within each measurement target, thus reducing space requirement and improving throughput, and simultaneously extract CD and overlay information. This method measures overlay errors and CDs by fitting the optical signals with spectra calculated from a model of the targets. Good correlation is obtained between the results from this method and that of several reference techniques, including empirical multi-pad DBO, CD-SEM, and IBO. We also perform total measurement uncertainty (TMU) analysis to evaluate the overall performance. We demonstrate that scatterometry provides a promising solution to meet the challenging overlay metrology requirement in DPT.

  16. An experimental study of the thermodynamic properties of 1,1-difluoroethane

    NASA Astrophysics Data System (ADS)

    Tamatsu, T.; Sato, T.; Sato, H.; Watanabe, K.

    1992-11-01

    Experimental vapor pressures and P-ρ-T data of an important alternative refrigerant, 1, 1-difluoroethane (HFC-152a), have been measured by means of a constant-volume method coupled with expansion procedures. Sixty P-ρ-T data were measured along eight isochores in a range of temperatures T from 330 to 440 K, at pressures P from 1.6 to 9.3 MPa, and at densities ρ from 51 to 811 kg·m-3. Forty-six vapor pressures were also measured at temperatures from 320 K to the critical temperature. The uncertainties of the temperature and pressure measurements are within ±7mK and ±2kPa, respectively, while the uncertainty of the density values is within ±0.1%. The purity of the sample used is 99.9 wt%. On the basis of the measurements along each isochore, five saturation points were determined and the critical pressure was determined by correlating the vapor-pressure measurements. The second and third virial coefficients for temperatures from 360 to 440 K have also been determined.

  17. Cantilever spring constant calibration using laser Doppler vibrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohler, Benjamin

    2007-06-15

    Uncertainty in cantilever spring constants is a critical issue in atomic force microscopy (AFM) force measurements. Though numerous methods exist for calibrating cantilever spring constants, the accuracy of these methods can be limited by both the physical models themselves as well as uncertainties in their experimental implementation. Here we report the results from two of the most common calibration methods, the thermal tune method and the Sader method. These were implemented on a standard AFM system as well as using laser Doppler vibrometry (LDV). Using LDV eliminates some uncertainties associated with optical lever detection on an AFM. It also offersmore » considerably higher signal to noise deflection measurements. We find that AFM and LDV result in similar uncertainty in the calibrated spring constants, about 5%, using either the thermal tune or Sader methods provided that certain limitations of the methods and instrumentation are observed.« less

  18. Accurate in situ measurement of complex refractive index and particle size in intralipid emulsions

    NASA Astrophysics Data System (ADS)

    Dong, Miao L.; Goyal, Kashika G.; Worth, Bradley W.; Makkar, Sorab S.; Calhoun, William R.; Bali, Lalit M.; Bali, Samir

    2013-08-01

    A first accurate measurement of the complex refractive index in an intralipid emulsion is demonstrated, and thereby the average scatterer particle size using standard Mie scattering calculations is extracted. Our method is based on measurement and modeling of the reflectance of a divergent laser beam from the sample surface. In the absence of any definitive reference data for the complex refractive index or particle size in highly turbid intralipid emulsions, we base our claim of accuracy on the fact that our work offers several critically important advantages over previously reported attempts. First, our measurements are in situ in the sense that they do not require any sample dilution, thus eliminating dilution errors. Second, our theoretical model does not employ any fitting parameters other than the two quantities we seek to determine, i.e., the real and imaginary parts of the refractive index, thus eliminating ambiguities arising from multiple extraneous fitting parameters. Third, we fit the entire reflectance-versus-incident-angle data curve instead of focusing on only the critical angle region, which is just a small subset of the data. Finally, despite our use of highly scattering opaque samples, our experiment uniquely satisfies a key assumption behind the Mie scattering formalism, namely, no multiple scattering occurs. Further proof of our method's validity is given by the fact that our measured particle size finds good agreement with the value obtained by dynamic light scattering.

  19. Accurate in situ measurement of complex refractive index and particle size in intralipid emulsions.

    PubMed

    Dong, Miao L; Goyal, Kashika G; Worth, Bradley W; Makkar, Sorab S; Calhoun, William R; Bali, Lalit M; Bali, Samir

    2013-08-01

    A first accurate measurement of the complex refractive index in an intralipid emulsion is demonstrated, and thereby the average scatterer particle size using standard Mie scattering calculations is extracted. Our method is based on measurement and modeling of the reflectance of a divergent laser beam from the sample surface. In the absence of any definitive reference data for the complex refractive index or particle size in highly turbid intralipid emulsions, we base our claim of accuracy on the fact that our work offers several critically important advantages over previously reported attempts. First, our measurements are in situ in the sense that they do not require any sample dilution, thus eliminating dilution errors. Second, our theoretical model does not employ any fitting parameters other than the two quantities we seek to determine, i.e., the real and imaginary parts of the refractive index, thus eliminating ambiguities arising from multiple extraneous fitting parameters. Third, we fit the entire reflectance-versus-incident-angle data curve instead of focusing on only the critical angle region, which is just a small subset of the data. Finally, despite our use of highly scattering opaque samples, our experiment uniquely satisfies a key assumption behind the Mie scattering formalism, namely, no multiple scattering occurs. Further proof of our method's validity is given by the fact that our measured particle size finds good agreement with the value obtained by dynamic light scattering.

  20. Fundamental limits of measurement in telecommunications: Experimental and modeling studies in a test optical network on proposal for the reform of telecommunication quantitations

    NASA Astrophysics Data System (ADS)

    Egan, James; McMillan, Normal; Denieffe, David

    2011-08-01

    Proposals for a review of the limits of measurement for telecommunications are made. The measures are based on adapting work from the area of chemical metrology for the field of telecommunications. Currie has introduced recommendations for defining the limits of measurement in chemical metrology and has identified three key fundamental limits of measurement. These are the critical level, the detection limit and the determination limit. Measurements on an optical system are used to illustrate the utility of these measures and discussion is given into the advantages of using these fundamental quantitations over existing methods.

  1. [Evaluation of accuracy and influence factors of bedside blood glucose monitoring in critically ill patients].

    PubMed

    Feng, Tao; Cao, Xiang-yuan

    2012-08-01

    To evaluate the accuracy and influence factors of point-of-care testing (POCT) for glucose in critically ill patients. Two hundred and forty critically ill patients aged ≥18 years in department of critical care medicine were enrolled. According to blood glucose level (BGL) during glucose control, patients were divided into three groups: (1) hypoglycemia group, BGL<4.5 mmol/L, n=32; (2) euglycemia group, BGL 4.5-8.3 mmol/L, n=138; (3) hyperglycemia group, BGL>8.3 mmol/L, n=70. The blood samples from vein, artery and capillary of patients were collected synchronically and the blood glucose of POCT were determined with glucose oxidase (GOD) and glucose dehydrogenase (GDH) methods, respectively, compared with blood glucose reference values of laboratory [hexokinase method (HK method)]. The accuracy of POCT for glucose and influence factors were analyzed statistically by the logistic regression method. (1) The inaccurate rates of glucose values in blood samples from vein, artery and capillary in hypoglycemia group (GDH method: 25.00%, 40.62%, 40.62%; GOD method: 59.38%, 71.88%, 71.88%) were significantly higher than those in euglycemia group (GDH method: 2.90%, 9.42%, 7.97%; GOD method: 18.12%, 27.54%, 27.54%) and hyperglycemia group (GDH method: 1.43%, 8.57%, 4.28%; GOD method: 11.43%, 8.57%, 11.43%, all P<0.01). (2) The average levels of difference for the glucose reference value of laboratory and the glucose value measured by glucometer in hypoglycemia group were 0.41-0.69 mmol/L (GDH method) and 0.92-1.18 mmol/L (GOD method), in euglycemia 0.16-0.33 mmol/L and 0.77-0.90 mmol/L, in hyperglycemia group -0.06-0.18 mmol/L and 0.56-0.76 mmol/L, respectively. (3) The correlation coefficients between the laboratory and glucometer in hypoglycemia group were respectively 0.812-0.853 (GDH method) and 0.723-0.816 (GOD method). The correlation coefficients in euglycemia group were 0.862-0.890 and 0.768-0.857. They were elevated to 0.922-0.957 and 0.896-0.922 in hyperglycemia group (all P<0.01). (4)On the influence factors of accuracy in POCT for glucose, BGL, acute physiology and chronic health evaluation II (APACHEII) score and hematocrit level were into the logistic regression equation. The accuracy of POCT for glucose was markedly affected by the BGL, severity of patients and hematocrit level during glucose control. Under hypoglycemia, the agreement between laboratory and glucometer measurements was obviously fallen and it tended to overestimate the patient's real glucose value.

  2. Vitamin D levels in critically ill patients with acute kidney injury: a protocol for a prospective cohort study (VID-AKI)

    PubMed Central

    Cameron, Lynda Katherine; Lei, Katie; Smith, Samantha; Doyle, Nanci Leigh; Doyle, James F; Flynn, Kate; Purchase, Nicola; Smith, John; Chan, Kathryn; Kamara, Farida; Kidane, Nardos Ghebremedhin; Forni, Lui G; Harrington, Dominic; Hampson, Geeta; Ostermann, Marlies

    2017-01-01

    Introduction Acute kidney injury (AKI) affects more than 50% of critically ill patients. The formation of calcitriol, the active vitamin D metabolite, from the main inactive circulating form, 25-hydroxyvitamin D (25(OH)D), occurs primarily in the proximal renal tubules. This results in a theoretical basis for reduction in levels of calcitriol over the course of an AKI. Vitamin D deficiency is highly prevalent in critically ill adults, and has been associated with increased rates of sepsis, longer hospital stays and increased mortality. The primary objective of this study is to perform serial measurements of 25(OH)D and calcitriol (1,25(OH)2D), as well as parathyroid hormone (PTH) and fibroblast growth factor 23 (FGF23) levels, in critically ill adult patients with and without AKI, and to determine whether patients with AKI have significantly lower vitamin D metabolite concentrations. The secondary objectives are to describe dynamic changes in vitamin D metabolites, PTH and FGF23 during critical illness; to compare vitamin D metabolite concentrations in patients with AKI with and without renal replacement therapy; and to investigate whether there is an association between vitamin D status and outcomes. Methods and analysis 230 general adult intensive care patients will be recruited. The AKI arm will include 115 critically ill patients with AKI Kidney Disease Improving Global Outcome stage II or stage III. The comparison group will include 115 patients who require cardiovascular or respiratory support, but who do not have AKI. Serial measurements of vitamin D metabolites and associated hormones will be taken on prespecified days. Patients will be recruited from two large teaching Trusts in England. Data will be analysed using standard statistical methods. Ethics and dissemination Ethical approval was obtained. Upon completion, the study team will submit the study report for publication in a peer-reviewed scientific journal and for conference presentation. Trial registration number NCT02869919; Pre-results. PMID:28706103

  3. [Prevention and management of refeeding syndrome in patients with chronic critical illness].

    PubMed

    Chen, Jun; Fan, Chaogang

    2016-07-01

    Nutritional support is an important means to treat the patients with chronic critical illness for commonly associated malnutrition. Refeeding syndrome is a serious complication during the process, mainly manifested as severe electrolyte with hypophosphataemia being the most common. Refeeding syndrome is not uncommon but it is often ignored. In our future clinical work, we need to recognize this chinical situation and use preventative and treatment measures. According to NICE clinical nutrition guideline, we discussed the risk factors, treatment methods and preventive measures of refeeding syndrome in patients with chronic critical illness. We argued that for patients with high risk refeeding syndrome, nutritional support treatment should be initially low calorie and slowly increased to complete requirement. Circulation capacity should be recovered, fluid balance must be closely monitored and supplement of vitamins, microelement, electrolytes should be noted. After the emergence of refeeding syndrome, we should reduce or even stop the calorie intake, give an active treatment for electrolyte disorder, provide vitamin B, and maintain the functions of multiple organs.

  4. Numerical estimation of structure constants in the three-dimensional Ising conformal field theory through Markov chain uv sampler

    NASA Astrophysics Data System (ADS)

    Herdeiro, Victor

    2017-09-01

    Herdeiro and Doyon [Phys. Rev. E 94, 043322 (2016), 10.1103/PhysRevE.94.043322] introduced a numerical recipe, dubbed uv sampler, offering precise estimations of the conformal field theory (CFT) data of the planar two-dimensional (2D) critical Ising model. It made use of scale invariance emerging at the critical point in order to sample finite sublattice marginals of the infinite plane Gibbs measure of the model by producing holographic boundary distributions. The main ingredient of the Markov chain Monte Carlo sampler is the invariance under dilation. This paper presents a generalization to higher dimensions with the critical 3D Ising model. This leads to numerical estimations of a subset of the CFT data—scaling weights and structure constants—through fitting of measured correlation functions. The results are shown to agree with the recent most precise estimations from numerical bootstrap methods [Kos, Poland, Simmons-Duffin, and Vichi, J. High Energy Phys. 08 (2016) 036, 10.1007/JHEP08(2016)036].

  5. Real-Time Monitoring of Critical Care Analytes in the Bloodstream with Chemical Sensors: Progress and Challenges.

    PubMed

    Frost, Megan C; Meyerhoff, Mark E

    2015-01-01

    We review approaches and challenges in developing chemical sensor-based methods to accurately and continuously monitor levels of key analytes in blood related directly to the status of critically ill hospitalized patients. Electrochemical and optical sensor-based technologies have been pursued to measure important critical care species in blood [i.e., oxygen, carbon dioxide, pH, electrolytes (K(+), Na(+), Cl(-), etc.), glucose, and lactate] in real-time or near real-time. The two main configurations examined to date for achieving this goal have been intravascular catheter sensors and patient attached ex vivo sensors with intermittent blood sampling via an attached indwelling catheter. We discuss the status of these configurations and the main issues affecting the accuracy of the measurements, including cell adhesion and thrombus formation on the surface of the sensors, sensor drift, sensor selectivity, etc. Recent approaches to mitigate these nagging performance issues that have prevented these technologies from clinical use are also discussed.

  6. Developing Science Virtual Test to Measure Students’ Critical Thinking on Living Things and Environmental Sustainability Theme

    NASA Astrophysics Data System (ADS)

    Akbar, M. N.; Firman, H.; Rusyati, L.

    2017-02-01

    Critical thinking is skill and ability to use of risk taking creativity to make a decision and knowledge as a result, analysis and synthesis that, evaluation, to acquire, information search, to develop thinking, as an individual aware of his or her own thinking. The aim of this study is to develop the science virtual test to measure students’ critical thinking on living things and environmental sustainability theme. The research method that is used in this research was descriptive research. The development of science virtual test item consist of five steps: (1) content analysis; (2) constructing the instrument (multiple choice) based on the elements of critical thinking by Inch; (3) validity judgment of the instrument by the expert; (4) legibility test of the instrument; (5) conducting the large field test. On the large field test was gained the results of validity and reliability of the test, difficulty index, discriminating power, and quality of distractor. The subjects of research were 8th grade students at International Junior High School in Bandung with 125 total of respondents. The coefficient alpha (α) was 0.747, the reliability of the test was categorized as ‘high’ and value of RXY correlation was 0.63 which mean that the validity of the test was categorized as ‘high’. These means that science virtual test can be used to measure student’s critical thinking with a good consistency. It is expected for other researcher to take this description as one of the basic information to be considered in developing science virtual test for improving students’ critical thinking by various kind of topic.

  7. RAPID-L Highly Automated Fast Reactor Concept Without Any Control Rods (2) Critical experiment of lithium-6 used in LEM and LIM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsunoda, Hirokazu; Sato, Osamu; Okajima, Shigeaki

    2002-07-01

    In order to achieve fully automated reactor operation of RAPID-L reactor, innovative reactivity control systems LEM, LIM, and LRM are equipped with lithium-6 as a liquid poison. Because lithium-6 has not been used as a neutron absorbing material of conventional fast reactors, measurements of the reactivity worth of Lithium-6 were performed at the Fast Critical Assembly (FCA) of Japan Atomic Energy Research Institute (JAERI). The FCA core was composed of highly enriched uranium and stainless steel samples so as to simulate the core spectrum of RAPID-L. The samples of 95% enriched lithium-6 were inserted into the core parallel to themore » core axis for the measurement of the reactivity worth at each position. It was found that the measured reactivity worth in the core region well agreed with calculated value by the method for the core designs of RAPID-L. Bias factors for the core design method were obtained by comparing between experimental and calculated results. The factors were used to determine the number of LEM and LIM equipped in the core to achieve fully automated operation of RAPID-L. (authors)« less

  8. High-speed scanning of critical structures in aviation using coordinate measurement machine and the laser ultrasonic.

    PubMed

    Swornowski, Pawel J

    2012-01-01

    Aviation is one of the know-how spheres containing a great deal of responsible sub-assemblies, in this case landing gear. The necessity for reducing production cycle times while achieving better quality compels metrologists to look for new and improved ways to perform inspection of critical structures. This article describes the ability to determine the shape deviation and location of defects in landing gear using coordinate measuring machines and laser ultrasonic with high-speed scanning. A nondestructive test is the basis for monitoring microcrack and corrosion propagation in the context of a damage-tolerant design approach. This article presents an overview of the basics and of the various metrological aspects of coordinate measurement and a nondestructive testing method in terms of high-speed scanning. The new test method (laser ultrasonic) promises to produce the necessary increase in inspection quality, but this is limited by the wide range of materials, geometries, and structure aeronautic parts used. A technique combining laser ultrasonic and F-SAFT (Fourier-Synthetic Aperture Focusing Technique) processing has been proposed for the detection of small defects buried in landing gear. The experimental results of landing gear inspection are also presented. © Wiley Periodicals, Inc.

  9. Photomask linewidth comparison by PTB and NIST

    NASA Astrophysics Data System (ADS)

    Bergmann, D.; Bodermann, B.; Bosse, H.; Buhr, E.; Dai, G.; Dixson, R.; Häßler-Grohne, W.; Hahm, K.; Wurm, M.

    2015-10-01

    We report the initial results of a recent bilateral comparison of linewidth or critical dimension (CD) calibrations on photomask line features between two national metrology institutes (NMIs): the National Institute of Standards and Technology (NIST) in the United States and the Physikalisch-Technische Bundesanstalt (PTB) in Germany. For the comparison, a chrome on glass (CoG) photomask was used which has a layout of line features down to 100 nm nominal size. Different measurement methods were used at both institutes. These included: critical dimension atomic force microscopy (CD-AFM), CD scanning electron microscopy (CD-SEM) and ultraviolet (UV) transmission optical microscopy. The measurands are CD at 50 % height of the features as well as sidewall angle and line width roughness (LWR) of the features. On the isolated opaque features, we found agreement of the CD measurements at the 3 nm to 5 nm level on most features - usually within the combined expanded uncertainties of the measurements.

  10. Single charging events on colloidal particles in a nonpolar liquid with surfactant

    NASA Astrophysics Data System (ADS)

    Schreuer, Caspar; Vandewiele, Stijn; Brans, Toon; Strubbe, Filip; Neyts, Kristiaan; Beunis, Filip

    2018-01-01

    Electrical charging of colloidal particles in nonpolar liquids due to surfactant additives is investigated intensively, motivated by its importance in a variety of applications. Most methods rely on average electrophoretic mobility measurements of many particles, which provide only indirect information on the charging mechanism. In the present work, we present a method that allows us to obtain direct information on the charging mechanism, by measuring the charge fluctuations on individual particles with a precision higher than the elementary charge using optical trapping electrophoresis. We demonstrate the capabilities of the method by studying the influence of added surfactant OLOA 11000 on the charging of single colloidal PMMA particles in dodecane. The particle charge and the frequency of charging events are investigated both below and above the critical micelle concentration (CMC) and with or without applying a DC offset voltage. It is found that at least two separate charging mechanisms are present below the critical micelle concentration. One mechanism is a process where the particle is stripped from negatively charged ionic molecules. An increase in the charging frequency with increased surfactant concentration suggests a second mechanism that involves single surfactant molecules. Above the CMC, neutral inverse micelles can also be involved in the charging process.

  11. MRI-based methods for quantification of the cerebral metabolic rate of oxygen

    PubMed Central

    Rodgers, Zachary B; Detre, John A

    2016-01-01

    The brain depends almost entirely on oxidative metabolism to meet its significant energy requirements. As such, the cerebral metabolic rate of oxygen (CMRO2) represents a key measure of brain function. Quantification of CMRO2 has helped elucidate brain functional physiology and holds potential as a clinical tool for evaluating neurological disorders including stroke, brain tumors, Alzheimer’s disease, and obstructive sleep apnea. In recent years, a variety of magnetic resonance imaging (MRI)-based CMRO2 quantification methods have emerged. Unlike positron emission tomography – the current “gold standard” for measurement and mapping of CMRO2 – MRI is non-invasive, relatively inexpensive, and ubiquitously available in modern medical centers. All MRI-based CMRO2 methods are based on modeling the effect of paramagnetic deoxyhemoglobin on the magnetic resonance signal. The various methods can be classified in terms of the MRI contrast mechanism used to quantify CMRO2: T2*, T2′, T2, or magnetic susceptibility. This review article provides an overview of MRI-based CMRO2 quantification techniques. After a brief historical discussion motivating the need for improved CMRO2 methodology, current state-of-the-art MRI-based methods are critically appraised in terms of their respective tradeoffs between spatial resolution, temporal resolution, and robustness, all of critical importance given the spatially heterogeneous and temporally dynamic nature of brain energy requirements. PMID:27089912

  12. 3D-profile measurement of advanced semiconductor features by using FIB as reference metrology

    NASA Astrophysics Data System (ADS)

    Takamasu, Kiyoshi; Iwaki, Yuuki; Takahashi, Satoru; Kawada, Hiroki; Ikota, Masami

    2017-03-01

    A novel method of sub-nanometer uncertainty for the 3D-profile measurement and LWR (Line Width Roughness) measurement by using FIB (Focused Ion Beam) processing, and TEM (Transmission Electron Microscope) and CD-SEM (Critical Dimension Scanning Electron Microscope) images measurement is proposed to standardize 3D-profile measurement through reference metrology. In this article, we apply the methodology to line profile measurements and roughness measurement of advanced FinFET (Fin-shaped Field-Effect Transistor) features. The FinFET features are horizontally sliced as a thin specimen by FIB micro sampling system. Horizontally images of the specimens are obtained then by a planar TEM. LWR is calculated from the edges positions on TEM images. Moreover, we already have demonstrated the novel on-wafer 3D-profile metrology as "FIB-to-CDSEM method" with FIB slope cut and CD-SEM measuring. Using the method, a few micrometers wide on a wafer is coated and cut by 45-degree slope using FIB tool. Then, the wafer is transferred to CD-SEM to measure the cross section image by top down CD-SEM measurement. We applied FIB-to-CDSEM method to a CMOS image sensor feature. The 45-degree slope cut surface is observed using AFM. The surface profile of slope cut surface and line profiles are analyzed for improving the accuracy of FIB-to-CDSEM method.

  13. A Correlational Study on Critical Thinking in Nursing as an Outcome Variable for Success

    ERIC Educational Resources Information Center

    Porter, Rebecca Jean

    2018-01-01

    Critical thinking is a required curricular outcome for nursing education; however, the literature shows a gap related to valid and reliable tools to measure critical thinking specific to nursing and relating that critical thinking measurement to meaningful outcomes. This study examined critical thinking scores, as measured by Assessment…

  14. Near field effect on elasticity measurement for cartilage-bone structure using Lamb wave method.

    PubMed

    Xu, Hao; Chen, Shigao; An, Kai-Nan; Luo, Zong-Ping

    2017-10-30

    Cartilage elasticity changes with cartilage degeneration. Hence, cartilage elasticity detection might be an alternative to traditional imaging methods for the early diagnosis of osteoarthritis. Based on the wave propagation measurement, Shear wave elastography (SWE) become an emerging non-invasive elasticity detection method. The wave propagation model, which is affected by tissue shapes, is crucial for elasticity estimating in SWE. However, wave propagation model for cartilage was unclear. This study aimed to establish a wave propagation model for the cartilage-bone structure. We fabricated a cartilage-bone structure, and studied the elasticity measurement and wave propagation by experimental and numerical Lamb wave method (LWM). Results indicated the wave propagation model satisfied the lamb wave theory for two-layered structure. Moreover, a near field region, which affects wave speed measurements and whose occurrence can be prevented if the wave frequency is larger than one critical frequency, was observed. Our findings would provide a theoretical foundation for further application of LWM in elasticity measurement of cartilage in vivo. It can help the application of LWM to the diagnosis of osteoarthritis.

  15. New Analysis Methods Estimate a Critical Property of Ethanol Fuel Blends

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-03-01

    To date there have been no adequate methods for measuring the heat of vaporization of complex mixtures. This research developed two separate methods for measuring this key property of ethanol and gasoline blends, including the ability to estimate heat of vaporization at multiple temperatures. Methods for determining heat of vaporization of gasoline-ethanol blends by calculation from a compositional analysis and by direct calorimetric measurement were developed. Direct measurement produced values for pure compounds in good agreement with literature. A range of hydrocarbon gasolines were shown to have heat of vaporization of 325 kJ/kg to 375 kJ/kg. The effect of addingmore » ethanol at 10 vol percent to 50 vol percent was significantly larger than the variation between hydrocarbon gasolines (E50 blends at 650 kJ/kg to 700 kJ/kg). The development of these new and accurate methods allows researchers to begin to both quantify the effect of fuel evaporative cooling on knock resistance, and exploit this effect for combustion of hydrocarbon-ethanol fuel blends in high-efficiency SI engines.« less

  16. Highly accurate adaptive TOF determination method for ultrasonic thickness measurement

    NASA Astrophysics Data System (ADS)

    Zhou, Lianjie; Liu, Haibo; Lian, Meng; Ying, Yangwei; Li, Te; Wang, Yongqing

    2018-04-01

    Determining the time of flight (TOF) is very critical for precise ultrasonic thickness measurement. However, the relatively low signal-to-noise ratio (SNR) of the received signals would induce significant TOF determination errors. In this paper, an adaptive time delay estimation method has been developed to improve the TOF determination’s accuracy. An improved variable step size adaptive algorithm with comprehensive step size control function is proposed. Meanwhile, a cubic spline fitting approach is also employed to alleviate the restriction of finite sampling interval. Simulation experiments under different SNR conditions were conducted for performance analysis. Simulation results manifested the performance advantage of proposed TOF determination method over existing TOF determination methods. When comparing with the conventional fixed step size, and Kwong and Aboulnasr algorithms, the steady state mean square deviation of the proposed algorithm was generally lower, which makes the proposed algorithm more suitable for TOF determination. Further, ultrasonic thickness measurement experiments were performed on aluminum alloy plates with various thicknesses. They indicated that the proposed TOF determination method was more robust even under low SNR conditions, and the ultrasonic thickness measurement accuracy could be significantly improved.

  17. Methods for assessing the quality of data in public health information systems: a critical review.

    PubMed

    Chen, Hong; Yu, Ping; Hailey, David; Wang, Ning

    2014-01-01

    The quality of data in public health information systems can be ensured by effective data quality assessment. In order to conduct effective data quality assessment, measurable data attributes have to be precisely defined. Then reliable and valid measurement methods for data attributes have to be used to measure each attribute. We conducted a systematic review of data quality assessment methods for public health using major databases and well-known institutional websites. 35 studies were eligible for inclusion in the study. A total of 49 attributes of data quality were identified from the literature. Completeness, accuracy and timeliness were the three most frequently assessed attributes of data quality. Most studies directly examined data values. This is complemented by exploring either data users' perception or documentation quality. However, there are limitations of current data quality assessment methods: a lack of consensus on attributes measured; inconsistent definition of the data quality attributes; a lack of mixed methods for assessing data quality; and inadequate attention to reliability and validity. Removal of these limitations is an opportunity for further improvement.

  18. Wireless Zigbee strain gage sensor system for structural health monitoring

    NASA Astrophysics Data System (ADS)

    Ide, Hiroshi; Abdi, Frank; Miraj, Rashid; Dang, Chau; Takahashi, Tatsuya; Sauer, Bruce

    2009-05-01

    A compact cell phone size radio frequency (ZigBee) wireless strain measurement sensor system to measure the structural strain deformation was developed. The developed system provides an accurate strain measurement data stream to the Internet for further Diagnostic and Prognostic (DPS) correlation. Existing methods of structural measurement by strain sensors (gauges) do not completely satisfy problems posed by continuous structural health monitoring. The need for efficient health monitoring methods with real-time requirements to bidirectional data flow from sensors and to a commanding device is becoming critical for keeping our daily life safety. The use of full-field strain measurement techniques could reduce costly experimental programs through better understanding of material behavior. Wireless sensor-network technology is a monitoring method that is estimated to grow rapidly providing potential for cost savings over traditional wired sensors. The many of currently available wireless monitoring methods have: the proactive and constant data rate character of the data streams rather than traditional reactive, event-driven data delivery; mostly static node placement on structures with limited number of nodes. Alpha STAR Electronics' wireless sensor network system, ASWN, addresses some of these deficiencies, making the system easier to operate. The ASWN strain measurement system utilizes off-the-shelf sensors, namely strain gauges, with an analog-to-digital converter/amplifier and ZigBee radio chips to keep cost lower. Strain data is captured by the sensor, converted to digital form and delivered to the ZigBee radio chip, which in turn broadcasts the information using wireless protocols to a Personal Data Assistant (PDA) or Laptop/Desktop computers. From here, data is forwarded to remote computers for higher-level analysis and feedback using traditional cellular and satellite communication or the Ethernet infrastructure. This system offers a compact size, lower cost, and temperature insensitivity for critical structural applications, which require immediate monitoring and feedback.

  19. Introduction of pinning centers into Sm1+xBa2Cu3+YO7-d coated conductor by reactive co-evaporation method

    NASA Astrophysics Data System (ADS)

    Kim, Gwan-Tae; Kim, Ho-Sup; Ha, Dong-Woo; Chung, Kook-Chae; Shinde, Kiran

    2018-02-01

    Sm1+xBa2Cu3+yO7-d (SmBCO)-coated conductors containing pinning centers were prepared by a reactive co-evaporation method using the EDDC (Evaporation using Drum in Dual Chamber) deposition system. Superconducting materials based on Sm, Ba, and Cu were evaporated in the evaporation chamber and deposited onto the drum-mounted substrate, while the deposited element reacted with oxygen and resulting in the SmBCO superconducting phase inside the reaction chamber. Tape-type samples (length = 30 cm, width = 4 mm, thickness = 0.1 mm) with the structure of Ag/SmBCO/LMO/MgO/Y2O3/Al2O3/Hastelloy were prepared, where the SmBCO film was spread along the tape length. The critical current was measured using the non-contact Hall-probe method, and the field dependences of the critical current under a high magnetic field were measured. The superconducting properties of the samples under a magnetic field were highly influenced by the composition of the SmBCO film. Furthermore, elemental mapping of the high-Jc SmBCO-coated conductor was measured by transmission electron microscopy coupled with energy-dispersive X-ray spectroscopy (TEM-EDX). Finally, we confirmed the Sm-related secondary phases take the role of pinning centers.

  20. Effects of problem-based learning vs. traditional lecture on Korean nursing students' critical thinking, problem-solving, and self-directed learning.

    PubMed

    Choi, Eunyoung; Lindquist, Ruth; Song, Yeoungsuk

    2014-01-01

    Problem-based learning (PBL) is a method widely used in nursing education to develop students' critical thinking skills to solve practice problems independently. Although PBL has been used in nursing education in Korea for nearly a decade, few studies have examined its effects on Korean nursing students' learning outcomes, and few Korean studies have examined relationships among these outcomes. The objectives of this study are to examine outcome abilities including critical thinking, problem-solving, and self-directed learning of nursing students receiving PBL vs. traditional lecture, and to examine correlations among these outcome abilities. A quasi-experimental non-equivalent group pretest-posttest design was used. First-year nursing students (N=90) were recruited from two different junior colleges in two cities (GY and GJ) in South Korea. In two selected educational programs, one used traditional lecture methods, while the other used PBL methods. Standardized self-administered questionnaires of critical thinking, problem-solving, and self-directed learning abilities were administered before and at 16weeks (after instruction). Learning outcomes were significantly positively correlated, however outcomes were not statistically different between groups. Students in the PBL group improved across all abilities measured, while student scores in the traditional lecture group decreased in problem-solving and self-directed learning. Critical thinking was positively associated with problem-solving and self-directed learning (r=.71, and r=.50, respectively, p<.001); problem-solving was positively associated with self-directed learning (r=.75, p<.001). Learning outcomes of PBL were not significantly different from traditional lecture in this small underpowered study, despite positive trends. Larger studies are recommended to study effects of PBL on critical student abilities. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Performance validity testing in neuropsychology: a clinical guide, critical review, and update on a rapidly evolving literature.

    PubMed

    Lippa, Sara M

    2018-04-01

    Over the past two decades, there has been much research on measures of response bias and myriad measures have been validated in a variety of clinical and research samples. This critical review aims to guide clinicians through the use of performance validity tests (PVTs) from test selection and administration through test interpretation and feedback. Recommended cutoffs and relevant test operating characteristics are presented. Other important issues to consider during test selection, administration, interpretation, and feedback are discussed including order effects, coaching, impact on test data, and methods to combine measures and improve predictive power. When interpreting performance validity measures, neuropsychologists must use particular caution in cases of dementia, low intelligence, English as a second language/minority cultures, or low education. PVTs provide valuable information regarding response bias and, under the right circumstances, can provide excellent evidence of response bias. Only after consideration of the entire clinical picture, including validity test performance, can concrete determinations regarding the validity of test data be made.

  2. Nondestructive ultrasonic measurement of bolt preload using the pulsed-phase locked-loop interferometer

    NASA Technical Reports Server (NTRS)

    Allison, S. G.; Heyman, J. S.

    1985-01-01

    Achieving accurate preload in threaded fasteners is an important and often critical problem which is encountered in nearly all sectors of government and industry. Conventional tensioning methods which rely on torque carry with them the disadvantage of requiring constant friction in the fastener in order to accurately correlate torque to preload. Since most of the applied torque typically overcomes friction rather than tensioning the fastener, small variations in friction can cause large variations in preload. An instrument called a pulsed phase locked loop interferometer, which was recently developed at NASA Langley, has found widespread use for measurement of stress as well as material properties. When used to measure bolt preload, this system detects changes in the fastener length and sound velocity which are independent of friction. The system is therefore capable of accurately establishing the correct change in bolt tension. This high resolution instrument has been used for precision measurement of preload in critical fasteners for numerous applications such as the space shuttle landing gear and helicopter main rotors.

  3. Methods and pitfalls of measuring thermal preference and tolerance in lizards.

    PubMed

    Camacho, Agustín; Rusch, Travis W

    2017-08-01

    Understanding methodological and biological sources of bias during the measurement of thermal parameters is essential for the advancement of thermal biology. For more than a century, studies on lizards have deepened our understanding of thermal ecophysiology, employing multiple methods to measure thermal preferences and tolerances. We reviewed 129 articles concerned with measuring preferred body temperature (PBT), voluntary thermal tolerance, and critical temperatures of lizards to offer: a) an overview of the methods used to measure and report these parameters, b) a summary of the methodological and biological factors affecting thermal preference and tolerance, c) recommendations to avoid identified pitfalls, and d) directions for continued progress in our application and understanding of these thermal parameters. We emphasize the need for more methodological and comparative studies. Lastly, we urge researchers to provide more detailed methodological descriptions and suggest ways to make their raw data more informative to increase the utility of thermal biology studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Three dimensional shape measurement of wear particle by iterative volume intersection

    NASA Astrophysics Data System (ADS)

    Wu, Hongkun; Li, Ruowei; Liu, Shilong; Rahman, Md Arifur; Liu, Sanchi; Kwok, Ngaiming; Peng, Zhongxiao

    2018-04-01

    The morphology of wear particle is a fundamental indicator where wear oriented machine health can be assessed. Previous research proved that thorough measurement of the particle shape allows more reliable explanation of the occurred wear mechanism. However, most of current particle measurement techniques are focused on extraction of the two-dimensional (2-D) morphology, while other critical particle features including volume and thickness are not available. As a result, a three-dimensional (3-D) shape measurement method is developed to enable a more comprehensive particle feature description. The developed method is implemented in three steps: (1) particle profiles in multiple views are captured via a camera mounted above a micro fluid channel; (2) a preliminary reconstruction is accomplished by the shape-from-silhouette approach with the collected particle contours; (3) an iterative re-projection process follows to obtain the final 3-D measurement by minimizing the difference between the original and the re-projected contours. Results from real data are presented, demonstrating the feasibility of the proposed method.

  5. Error analysis in inverse scatterometry. I. Modeling.

    PubMed

    Al-Assaad, Rayan M; Byrne, Dale M

    2007-02-01

    Scatterometry is an optical technique that has been studied and tested in recent years in semiconductor fabrication metrology for critical dimensions. Previous work presented an iterative linearized method to retrieve surface-relief profile parameters from reflectance measurements upon diffraction. With the iterative linear solution model in this work, rigorous models are developed to represent the random and deterministic or offset errors in scatterometric measurements. The propagation of different types of error from the measurement data to the profile parameter estimates is then presented. The improvement in solution accuracies is then demonstrated with theoretical and experimental data by adjusting for the offset errors. In a companion paper (in process) an improved optimization method is presented to account for unknown offset errors in the measurements based on the offset error model.

  6. Probing the Interplay of Size, Shape, and Solution Environment in Macromolecular Diffusion Using a Simple Refraction Experiment

    ERIC Educational Resources Information Center

    Mankidy, Bijith D.; Coutinho, Cecil A.; Gupta, Vinay K.

    2010-01-01

    The diffusion coefficient of polymers is a critical parameter in biomedicine, catalysis, chemical separations, nanotechnology, and other industrial applications. Here, measurement of macromolecular diffusion in solutions is described using a visually instructive, undergraduate-level optical refraction experiment based on Weiner's method. To…

  7. Perspectives: Using Critical Incidents to Understand ESL Student Satisfaction

    ERIC Educational Resources Information Center

    Walker, John

    2015-01-01

    In a marketized environment, ESL providers, in common with other postcompulsory educational institutions, canvass student satisfaction with their services. While the predominant method is likely to be based on tick-box questionnaires using Likert scales that measure degrees of satisfaction, qualitative methodology is an option when rich data is…

  8. 49 CFR Appendix F to Part 229 - Recommended Practices for Design and Safety Analysis

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... expected order of use; (v) Group similar controls together; (vi) Design for high stimulus-response compatibility (geometric and conceptual); (vii) Design safety-critical controls to require more than one... description of all backup methods of operation; and (s) The configuration/revision control measures designed...

  9. 49 CFR Appendix F to Part 229 - Recommended Practices for Design and Safety Analysis

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... expected order of use; (v) Group similar controls together; (vi) Design for high stimulus-response compatibility (geometric and conceptual); (vii) Design safety-critical controls to require more than one... description of all backup methods of operation; and (s) The configuration/revision control measures designed...

  10. 49 CFR Appendix F to Part 229 - Recommended Practices for Design and Safety Analysis

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... expected order of use; (v) Group similar controls together; (vi) Design for high stimulus-response compatibility (geometric and conceptual); (vii) Design safety-critical controls to require more than one... description of all backup methods of operation; and (s) The configuration/revision control measures designed...

  11. Evaluating Quality Management in University Departments

    ERIC Educational Resources Information Center

    Becket, Nina; Brookes, Maureen

    2006-01-01

    Purpose: Despite the abundance of research on quality management there is no universal consensus on how best to measure quality in higher education. This paper undertakes a critical evaluation of the different methods used to assess the quality of provision in higher education departments in the UK. Design/methodology/approach: Drawing on relevant…

  12. Scalable Integrated Region-Based Image Retrieval Using IRM and Statistical Clustering.

    ERIC Educational Resources Information Center

    Wang, James Z.; Du, Yanping

    Statistical clustering is critical in designing scalable image retrieval systems. This paper presents a scalable algorithm for indexing and retrieving images based on region segmentation. The method uses statistical clustering on region features and IRM (Integrated Region Matching), a measure developed to evaluate overall similarity between images…

  13. Monitoring changes in exotic vegetation

    Treesearch

    Robert D. Sutter

    1998-01-01

    Ecological monitoring provides critical information for management decisions by measuring changes in managed and unmanaged populations, communities and ecological systems. It integrates ecology, goal and objective setting, sampling design, sampling methods, and statistical analysis. It is a topic that I, with a team of Nature Conservancy ecologists, teach in a six day...

  14. The Use of Research Libraries: A Comment about the Pittsburgh Study and Its Critics.

    ERIC Educational Resources Information Center

    Peat, W. Leslie

    1981-01-01

    Reviews the controversy surrounding the Pittsburgh study of library circulation and collection usage and proposes the use of citation analysis techniques as an acceptable method for measuring research use of a research library which will complement circulation studies. Five references are listed. (RAA)

  15. Sleep duration and all-cause mortality: a critical review of measurement and associations

    PubMed Central

    Kurina, Lianne M.; McClintock, Martha K.; Chen, Jen-Hao; Waite, Linda J.; Thisted, Ronald A.; Lauderdale, Diane S.

    2013-01-01

    Purpose Variation in sleep duration has been linked with mortality risk. The purpose of this review is to provide an updated evaluation of the literature on sleep duration and mortality, including a critical examination of sleep duration measurement and an examination of correlates of self-reported sleep duration. Methods We did a systematic search of studies reporting associations between sleep duration and all-cause mortality and extracted the sleep duration measure and the measure(s) of association. Results We identified 42 prospective studies of sleep duration and mortality drawing on 35 distinct study populations across the globe. Unlike previous reviews, we find that the published literature does not support a consistent finding of an association between self-reported sleep duration and mortality. Most studies have employed survey measures of sleep duration, which are not highly correlated with estimates based on physiologic measures. Conclusions Despite a large body of literature, it is premature to conclude, as previous reviews have, that a robust, U-shaped association between sleep duration and mortality risk exists across populations. Careful attention must be paid to measurement, response bias, confounding, and reverse causation in the interpretation of associations between sleep duration and mortality. PMID:23622956

  16. Calibration procedure of Hukseflux SR25 to Establish the Diffuse Reference for the Outdoor Broadband Radiometer Calibration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reda, Ibrahim M.; Andreas, Afshin M.

    2017-08-01

    Accurate pyranometer calibrations, traceable to internationally recognized standards, are critical for solar irradiance measurements. One calibration method is the component summation method, where the pyranometers are calibrated outdoors under clear sky conditions, and the reference global solar irradiance is calculated as the sum of two reference components, the diffuse horizontal and subtended beam solar irradiances. The beam component is measured with pyrheliometers traceable to the World Radiometric Reference, while there is no internationally recognized reference for the diffuse component. In the absence of such a reference, we present a method to consistently calibrate pyranometers for measuring the diffuse component. Themore » method is based on using a modified shade/unshade method and a pyranometer with less than 0.5 W/m2 thermal offset. The calibration result shows that the responsivity of Hukseflux SR25 pyranometer equals 10.98 uV/(W/m2) with +/-0.86 percent uncertainty.« less

  17. Strain, biochemistry, and cultivation-dependent measurement variability of algal biomass composition.

    PubMed

    Laurens, Lieve M L; Van Wychen, Stefanie; McAllister, Jordan P; Arrowsmith, Sarah; Dempster, Thomas A; McGowen, John; Pienkos, Philip T

    2014-05-01

    Accurate compositional analysis in biofuel feedstocks is imperative; the yields of individual components can define the economics of an entire process. In the nascent industry of algal biofuels and bioproducts, analytical methods that have been deemed acceptable for decades are suddenly critical for commercialization. We tackled the question of how the strain and biochemical makeup of algal cells affect chemical measurements. We selected a set of six procedures (two each for lipids, protein, and carbohydrates): three rapid fingerprinting methods and three advanced chromatography-based methods. All methods were used to measure the composition of 100 samples from three strains: Scenedesmus sp., Chlorella sp., and Nannochloropsis sp. The data presented point not only to species-specific discrepancies but also to cell biochemistry-related discrepancies. There are cases where two respective methods agree but the differences are often significant with over- or underestimation of up to 90%, likely due to chemical interferences with the rapid spectrophotometric measurements. We provide background on the chemistry of interfering reactions for the fingerprinting methods and conclude that for accurate compositional analysis of algae and process and mass balance closure, emphasis should be placed on unambiguous characterization using methods where individual components are measured independently. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Effect of simulation-based emergency cardiac arrest education on nursing students' self-efficacy and critical thinking skills: Roleplay versus lecture.

    PubMed

    Kim, Eunsook

    2018-02-01

    Simulation education is a learning method for improving self-efficacy and critical thinking skills. However, not much study has been done on how to use it for education on emergency cardiac arrest situations, for which a multidisciplinary team approach is required. This study investigated the effects of simulation education on nursing students' self-efficacy and critical thinking skills in emergency cardiac arrest situations. A quasi-experimental research approach with a crossover design was used to compare two types of simulation instruction methods. This study was conducted with 76 nursing students divided into two groups by order of instruction methods, in November and December 2016. Both groups of participants experienced a simulation lesson based on the same emergency scenario. Group A first completed a roleplay of an emergency cardiac arrest situation in a clinical setting, while Group B first listened to a lecture on the procedure. After ten days, Group A repeated the simulation exercise after listening to the lecture, while Group B completed the simulation exercise after the roleplay. The students' self-efficacy and critical thinking skills were measured using a questionnaire before and after each session. In the first session, self-efficacy and critical thinking skills scores increased greatly from pretest to posttest for Group A in comparison to Group B; no statistically significant difference was found between the two groups. In the second session, Group B showed a significant increase between pretest and posttest, while Group A showed no significant difference. Conducting the simulation exercise after the roleplay was a more effective teaching method than conducting it after the lecture. Moreover, having the nursing students assume various roles in realistic roleplay situations combined with simulation exercises led to a deeper understanding of clinical situations and improved their self-efficacy and critical thinking skills. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Introduction to the Special Series: Current Directions for Measuring Parenting Constructs to Inform Prevention Science.

    PubMed

    Lindhiem, Oliver; Shaffer, Anne

    2017-04-01

    Parenting behaviors are multifaceted and dynamic and therefore challenging to quantify. Measurement methods have critical implications for study results, particularly for prevention trials designed to modify parenting behaviors. Although multiple approaches can complement one another and contribute to a more complete understanding of prevention trials, the assumptions and implications of each approach are not always clearly addressed. Greater attention to the measurement of complex constructs such as parenting is needed to advance the field of prevention science. This series examines the challenges of measuring changes in parenting behaviors in the context of prevention trials. All manuscripts in the special series address measurement issues and make practical recommendations for prevention researchers. Manuscripts in this special series include (1) empirical studies that demonstrate novel measurement approaches, (2) re-analyses of prevention trial outcome data directly comparing and contrasting two or more methods, and (3) a statistical primer and practical guide to analyzing proportion data.

  20. The Value of Measurement for Development of Nursing Knowledge:Underlying Philosophy, Contributions and Critiques.

    PubMed

    Durepos, Pamela; Orr, Elizabeth; Ploeg, Jenny; Kaasalainen, Sharon

    2018-06-26

    A philosophical discussion of constructive realism and measurement in the development of nursing knowledge is presented. Through Carper's four patterns of knowing, nurses come to know a person holistically. However, measurement as a source for nursing knowledge has been criticized for underlying positivism and reductionist approach to exploring reality. Which seems mal-alignment with person-centered care. Discussion paper. Constructive realism bridges positivism and constructivism, facilitating the measurement of physical and psychological phenomena. Reduction of complex phenomena and theoretical constructs into measurable properties is essential to building nursing's empiric knowledge and facilitates (rather than inhibits) person-knowing. Nurses should consider constructive realism as a philosophy to underpin their practice. This philosophy supports measurement as a primary method of inquiry in nursing research and clinical practice. Nurses can carefully select, and purposefully integrate, measurement tools with other methods of inquiry (such as qualitative research methods) to demonstrate the usefulness of nursing interventions and highlight nursing as a science. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  1. Critical cerebral perfusion pressure at high intracranial pressure measured by induced cerebrovascular and intracranial pressure reactivity.

    PubMed

    Bragin, Denis E; Statom, Gloria L; Yonas, Howard; Dai, Xingping; Nemoto, Edwin M

    2014-12-01

    The lower limit of cerebral blood flow autoregulation is the critical cerebral perfusion pressure at which cerebral blood flow begins to fall. It is important that cerebral perfusion pressure be maintained above this level to ensure adequate cerebral blood flow, especially in patients with high intracranial pressure. However, the critical cerebral perfusion pressure of 50 mm Hg, obtained by decreasing mean arterial pressure, differs from the value of 30 mm Hg, obtained by increasing intracranial pressure, which we previously showed was due to microvascular shunt flow maintenance of a falsely high cerebral blood flow. The present study shows that the critical cerebral perfusion pressure, measured by increasing intracranial pressure to decrease cerebral perfusion pressure, is inaccurate but accurately determined by dopamine-induced dynamic intracranial pressure reactivity and cerebrovascular reactivity. Cerebral perfusion pressure was decreased either by increasing intracranial pressure or decreasing mean arterial pressure and the critical cerebral perfusion pressure by both methods compared. Cortical Doppler flux, intracranial pressure, and mean arterial pressure were monitored throughout the study. At each cerebral perfusion pressure, we measured microvascular RBC flow velocity, blood-brain barrier integrity (transcapillary dye extravasation), and tissue oxygenation (reduced nicotinamide adenine dinucleotide) in the cerebral cortex of rats using in vivo two-photon laser scanning microscopy. University laboratory. Male Sprague-Dawley rats. At each cerebral perfusion pressure, dopamine-induced arterial pressure transients (~10 mm Hg, ~45 s duration) were used to measure induced intracranial pressure reactivity (Δ intracranial pressure/Δ mean arterial pressure) and induced cerebrovascular reactivity (Δ cerebral blood flow/Δ mean arterial pressure). At a normal cerebral perfusion pressure of 70 mm Hg, 10 mm Hg mean arterial pressure pulses had no effect on intracranial pressure or cerebral blood flow (induced intracranial pressure reactivity = -0.03 ± 0.07 and induced cerebrovascular reactivity = -0.02 ± 0.09), reflecting intact autoregulation. Decreasing cerebral perfusion pressure to 50 mm Hg by increasing intracranial pressure increased induced intracranial pressure reactivity and induced cerebrovascular reactivity to 0.24 ± 0.09 and 0.31 ± 0.13, respectively, reflecting impaired autoregulation (p < 0.05). By static cerebral blood flow, the first significant decrease in cerebral blood flow occurred at a cerebral perfusion pressure of 30 mm Hg (0.71 ± 0.08, p < 0.05). Critical cerebral perfusion pressure of 50 mm Hg was accurately determined by induced intracranial pressure reactivity and induced cerebrovascular reactivity, whereas the static method failed.

  2. Measuring Road Network Vulnerability with Sensitivity Analysis

    PubMed Central

    Jun-qiang, Leng; Long-hai, Yang; Liu, Wei-yi; Zhao, Lin

    2017-01-01

    This paper focuses on the development of a method for road network vulnerability analysis, from the perspective of capacity degradation, which seeks to identify the critical infrastructures in the road network and the operational performance of the whole traffic system. This research involves defining the traffic utility index and modeling vulnerability of road segment, route, OD (Origin Destination) pair and road network. Meanwhile, sensitivity analysis method is utilized to calculate the change of traffic utility index due to capacity degradation. This method, compared to traditional traffic assignment, can improve calculation efficiency and make the application of vulnerability analysis to large actual road network possible. Finally, all the above models and calculation method is applied to actual road network evaluation to verify its efficiency and utility. This approach can be used as a decision-supporting tool for evaluating the performance of road network and identifying critical infrastructures in transportation planning and management, especially in the resource allocation for mitigation and recovery. PMID:28125706

  3. Directly Measuring the Degree of Quantum Coherence using Interference Fringes

    NASA Astrophysics Data System (ADS)

    Wang, Yi-Tao; Tang, Jian-Shun; Wei, Zhi-Yuan; Yu, Shang; Ke, Zhi-Jin; Xu, Xiao-Ye; Li, Chuan-Feng; Guo, Guang-Can

    2017-01-01

    Quantum coherence is the most distinguished feature of quantum mechanics. It lies at the heart of the quantum-information technologies as the fundamental resource and is also related to other quantum resources, including entanglement. It plays a critical role in various fields, even in biology. Nevertheless, the rigorous and systematic resource-theoretic framework of coherence has just been developed recently, and several coherence measures are proposed. Experimentally, the usual method to measure coherence is to perform state tomography and use mathematical expressions. Here, we alternatively develop a method to measure coherence directly using its most essential behavior—the interference fringes. The ancilla states are mixed into the target state with various ratios, and the minimal ratio that makes the interference fringes of the "mixed state" vanish is taken as the quantity of coherence. We also use the witness observable to witness coherence, and the optimal witness constitutes another direct method to measure coherence. For comparison, we perform tomography and calculate l1 norm of coherence, which coincides with the results of the other two methods in our situation. Our methods are explicit and robust, providing a nice alternative to the tomographic technique.

  4. Directly Measuring the Degree of Quantum Coherence using Interference Fringes.

    PubMed

    Wang, Yi-Tao; Tang, Jian-Shun; Wei, Zhi-Yuan; Yu, Shang; Ke, Zhi-Jin; Xu, Xiao-Ye; Li, Chuan-Feng; Guo, Guang-Can

    2017-01-13

    Quantum coherence is the most distinguished feature of quantum mechanics. It lies at the heart of the quantum-information technologies as the fundamental resource and is also related to other quantum resources, including entanglement. It plays a critical role in various fields, even in biology. Nevertheless, the rigorous and systematic resource-theoretic framework of coherence has just been developed recently, and several coherence measures are proposed. Experimentally, the usual method to measure coherence is to perform state tomography and use mathematical expressions. Here, we alternatively develop a method to measure coherence directly using its most essential behavior-the interference fringes. The ancilla states are mixed into the target state with various ratios, and the minimal ratio that makes the interference fringes of the "mixed state" vanish is taken as the quantity of coherence. We also use the witness observable to witness coherence, and the optimal witness constitutes another direct method to measure coherence. For comparison, we perform tomography and calculate l_{1} norm of coherence, which coincides with the results of the other two methods in our situation. Our methods are explicit and robust, providing a nice alternative to the tomographic technique.

  5. extrap: Software to assist the selection of extrapolation methods for moving-boat ADCP streamflow measurements

    NASA Astrophysics Data System (ADS)

    Mueller, David S.

    2013-04-01

    Selection of the appropriate extrapolation methods for computing the discharge in the unmeasured top and bottom parts of a moving-boat acoustic Doppler current profiler (ADCP) streamflow measurement is critical to the total discharge computation. The software tool, extrap, combines normalized velocity profiles from the entire cross section and multiple transects to determine a mean profile for the measurement. The use of an exponent derived from normalized data from the entire cross section is shown to be valid for application of the power velocity distribution law in the computation of the unmeasured discharge in a cross section. Selected statistics are combined with empirically derived criteria to automatically select the appropriate extrapolation methods. A graphical user interface (GUI) provides the user tools to visually evaluate the automatically selected extrapolation methods and manually change them, as necessary. The sensitivity of the total discharge to available extrapolation methods is presented in the GUI. Use of extrap by field hydrographers has demonstrated that extrap is a more accurate and efficient method of determining the appropriate extrapolation methods compared with tools currently (2012) provided in the ADCP manufacturers' software.

  6. A pattern-based method to automate mask inspection files

    NASA Astrophysics Data System (ADS)

    Kamal Baharin, Ezni Aznida Binti; Muhsain, Mohamad Fahmi Bin; Ahmad Ibrahim, Muhamad Asraf Bin; Ahmad Noorhani, Ahmad Nurul Ihsan Bin; Sweis, Jason; Lai, Ya-Chieh; Hurat, Philippe

    2017-03-01

    Mask inspection is a critical step in the mask manufacturing process in order to ensure all dimensions printed are within the needed tolerances. This becomes even more challenging as the device nodes shrink and the complexity of the tapeout increases. Thus, the amount of measurement points and their critical dimension (CD) types are increasing to ensure the quality of the mask. In addition to the mask quality, there is a significant amount of manpower needed when the preparation and debugging of this process are not automated. By utilizing a novel pattern search technology with the ability to measure and report match region scan-line (edge) measurements, we can create a flow to find, measure and mark all metrology locations of interest and provide this automated report to the mask shop for inspection. A digital library is created based on the technology product and node which contains the test patterns to be measured. This paper will discuss how these digital libraries will be generated and then utilized. As a time-critical part of the manufacturing process, this can also reduce the data preparation cycle time, minimize the amount of manual/human error in naming and measuring the various locations, reduce the risk of wrong/missing CD locations, and reduce the amount of manpower needed overall. We will also review an example pattern and how the reporting structure to the mask shop can be processed. This entire process can now be fully automated.

  7. Effect of abdominal negative-pressure wound therapy on the measurement of intra-abdominal pressure.

    PubMed

    García, Alberto Federico; Sánchez, Álvaro Ignacio; Gutiérrez, Álvaro José; Bayona, Juan Gabriel; Naranjo, María Paula; Lago, Sebastián; Puyana, Juan Carlos

    2018-07-01

    In critically ill surgical patients undergoing abdominal negative-pressure wound therapy (NPWT), it remains uncertain whether or not intra-abdominal pressure (IAP) measurements should be obtained when NPWT is activated. We aimed to determine agreement between IAP measured with and without NPWT. In this analytic cross-sectional study, critically ill surgical adults (≥18 y) requiring abdominal NPWT for temporary abdominal closure after a damage control laparotomy were selected. Patients with urinary tract injuries or with pelvic packing were excluded. Paired IAP measures were performed in the same patient, with and without NPWT; two different operators performed the measures unaware of the other's result. Bland-Altman methods assessed the agreement between the two measures. Subgroup analyses (trauma and nontrauma) were performed. There were 198 IAP measures (99 pairs) in 38 patients. Mean IAP with and without NPWT were 8.33 (standard deviation 4.01) and 8.65 (standard deviation 4.04), respectively. Mean IAP difference was -0.323 (95% confidence interval -0.748 to 0.101), and reference range for difference was -4.579 to 3.932 (P = 0.864). From 112 IAP measures (56 pairs) in 21 trauma patients, mean IAP difference was -0.268 (95% confidence interval -0.867 to 0.331), and reference range for the difference was -4.740 to 4.204 (P = 0.427). There was no statistically significant disagreement in IAP measures. IAP could be measured with or without NPWT. In critically ill surgical patients with abdominal NPWT for temporary abdominal closure, monitoring and management of IAP either with or without NPWT is recommended. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Quantifying glenoid bone loss in anterior shoulder instability: reliability and accuracy of 2-dimensional and 3-dimensional computed tomography measurement techniques.

    PubMed

    Bois, Aaron J; Fening, Stephen D; Polster, Josh; Jones, Morgan H; Miniaci, Anthony

    2012-11-01

    Glenoid support is critical for stability of the glenohumeral joint. An accepted noninvasive method of quantifying glenoid bone loss does not exist. To perform independent evaluations of the reliability and accuracy of standard 2-dimensional (2-D) and 3-dimensional (3-D) computed tomography (CT) measurements of glenoid bone deficiency. Descriptive laboratory study. Two sawbone models were used; one served as a model for 2 anterior glenoid defects and the other for 2 anteroinferior defects. For each scapular model, predefect and defect data were collected for a total of 6 data sets. Each sample underwent 3-D laser scanning followed by CT scanning. Six physicians measured linear indicators of bone loss (defect length and width-to-length ratio) on both 2-D and 3-D CT and quantified bone loss using the glenoid index method on 2-D CT and using the glenoid index, ratio, and Pico methods on 3-D CT. The intraclass correlation coefficient (ICC) was used to assess agreement, and percentage error was used to compare radiographic and true measurements. With use of 2-D CT, the glenoid index and defect length measurements had the least percentage error (-4.13% and 7.68%, respectively); agreement was very good (ICC, .81) for defect length only. With use of 3-D CT, defect length (0.29%) and the Pico(1) method (4.93%) had the least percentage error. Agreement was very good for all linear indicators of bone loss (range, .85-.90) and for the ratio linear and Pico surface area methods used to quantify bone loss (range, .84-.98). Overall, 3-D CT results demonstrated better agreement and accuracy compared to 2-D CT. None of the methods assessed in this study using 2-D CT was found to be valid, and therefore, 2-D CT is not recommended for these methods. However, the length of glenoid defects can be reliably and accurately measured on 3-D CT. The Pico and ratio techniques are most reliable; however, the Pico(1) method accurately quantifies glenoid bone loss in both the anterior and anteroinferior locations. Future work is required to implement valid imaging techniques of glenoid bone loss into clinical practice. This is one of the only studies to date that has investigated both the reliability and accuracy of multiple indicators and quantification methods that evaluate glenoid bone loss in anterior glenohumeral instability. These data are critical to ensure valid methods are used for preoperative assessment and to determine when a glenoid bone augmentation procedure is indicated.

  9. Stress levels of critical care doctors in India: A national survey

    PubMed Central

    Amte, Rahul; Munta, Kartik; Gopal, Palepu B.

    2015-01-01

    Background: Doctors working in critical care units are prone to higher stress due to various factors such as higher mortality and morbidity, demanding service conditions and need for higher knowledge and technical skill. Aim: The aim was to evaluate the stress level and the causative stressors in doctors working in critical care units in India. Materials and Methods: A two modality questionnaire-based cross-sectional survey was conducted. In manual mode, randomly selected delegates attending the annual congress of Indian Society of Critical Care Medicine filled the questionnaire. In the electronic mode, the questionnaires were E-mailed to critical care doctors. These questionnaires were based on General Health Questionnaire-12 (GHQ-12). Completely filled 242 responses were utilized for comparative and correlation analysis. Results: Prevalence of moderate to severe stress level was 40% with a mean score of 2 on GHQ-12 scale. Too much responsibility at times and managing VIP patients ranked as the top two stressors studied, while the difficult relationship with colleagues and sexual harassment were the least. Intensivists were spending longest hours in the Intensive Care Unit (ICU) followed by pulmonologists and anesthetists. The mean number of ICU bed critical care doctors entrusted with was 13.2 ± 6.3. Substance abuse to relieve stress was reported as alcohol (21%), anxiolytic or antidepressants (18%) and smoking (14%). Conclusion: Despite the higher workload, stress levels measured in our survey in Indian critical care doctors were lower compared to International data. Substantiation of this data through a wider study and broad-based measures to improve the quality of critical care units and quality of the lives of these doctors is the need of the hour. PMID:25983431

  10. Identification of features in indexed data and equipment therefore

    DOEpatents

    Jarman, Kristin H [Richland, WA; Daly, Don Simone [Richland, WA; Anderson, Kevin K [Richland, WA; Wahl, Karen L [Richland, WA

    2002-04-02

    Embodiments of the present invention provide methods of identifying a feature in an indexed dataset. Such embodiments encompass selecting an initial subset of indices, the initial subset of indices being encompassed by an initial window-of-interest and comprising at least one beginning index and at least one ending index; computing an intensity weighted measure of dispersion for the subset of indices using a subset of responses corresponding to the subset of indices; and comparing the intensity weighted measure of dispersion to a dispersion critical value determined from an expected value of the intensity weighted measure of dispersion under a null hypothesis of no transient feature present. Embodiments of the present invention also encompass equipment configured to perform the methods of the present invention.

  11. Magnetic field dependence of spin torque switching in nanoscale magnetic tunnel junctions

    NASA Astrophysics Data System (ADS)

    Yang, Liu; Rowlands, Graham; Katine, Jordan; Langer, Juergen; Krivorotov, Ilya

    2012-02-01

    Magnetic random access memory based on spin transfer torque effect in nanoscale magnetic tunnel junctions (STT-RAM) is emerging as a promising candidate for embedded and stand-alone computer memory. An important performance parameter of STT-RAM is stability of its free magnetic layer against thermal fluctuations. Measurements of the free layer switching probability as a function of sub-critical voltage at zero effective magnetic field (read disturb rate or RDR measurements) have been proposed as a method for quantitative evaluation of the free layer thermal stability at zero voltage. In this presentation, we report RDR measurement as a function of external magnetic field, which provide a test of the RDR method self-consistency and reliability.

  12. Developing measurement indices to enhance protection and resilience of critical infrastructure and key resources.

    PubMed

    Fisher, Ronald E; Norman, Michael

    2010-07-01

    The US Department of Homeland Security (DHS) is developing indices to better assist in the risk management of critical infrastructures. The first of these indices is the Protective Measures Index - a quantitative index that measures overall protection across component categories: physical security, security management, security force, information sharing, protective measures and dependencies. The Protective Measures Index, which can also be recalculated as the Vulnerability Index, is a way to compare differing protective measures (eg fence versus security training). The second of these indices is the Resilience Index, which assesses a site's resilience and consists of three primary components: robustness, resourcefulness and recovery. The third index is the Criticality Index, which assesses the importance of a facility. The Criticality Index includes economic, human, governance and mass evacuation impacts. The Protective Measures Index, Resilience Index and Criticality Index are being developed as part of the Enhanced Critical Infrastructure Protection initiative that DHS protective security advisers implement across the nation at critical facilities. This paper describes two core themes: determination of the vulnerability, resilience and criticality of a facility and comparison of the indices at different facilities.

  13. Method of identifying features in indexed data

    DOEpatents

    Jarman, Kristin H [Richland, WA; Daly, Don Simone [Richland, WA; Anderson, Kevin K [Richland, WA; Wahl, Karen L [Richland, WA

    2001-06-26

    The present invention is a method of identifying features in indexed data, especially useful for distinguishing signal from noise in data provided as a plurality of ordered pairs. Each of the plurality of ordered pairs has an index and a response. The method has the steps of: (a) providing an index window having a first window end located on a first index and extending across a plurality of indices to a second window end; (b) selecting responses corresponding to the plurality of indices within the index window and computing a measure of dispersion of the responses; and (c) comparing the measure of dispersion to a dispersion critical value. Advantages of the present invention include minimizing signal to noise ratio, signal drift, varying baseline signal and combinations thereof.

  14. Strain-Based Damage Determination Using Finite Element Analysis for Structural Health Management

    NASA Technical Reports Server (NTRS)

    Hochhalter, Jacob D.; Krishnamurthy, Thiagaraja; Aguilo, Miguel A.

    2016-01-01

    A damage determination method is presented that relies on in-service strain sensor measurements. The method employs a gradient-based optimization procedure combined with the finite element method for solution to the forward problem. It is demonstrated that strains, measured at a limited number of sensors, can be used to accurately determine the location, size, and orientation of damage. Numerical examples are presented to demonstrate the general procedure. This work is motivated by the need to provide structural health management systems with a real-time damage characterization. The damage cases investigated herein are characteristic of point-source damage, which can attain critical size during flight. The procedure described can be used to provide prognosis tools with the current damage configuration.

  15. Comparing performance on the MNREAD iPad application with the MNREAD acuity chart.

    PubMed

    Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E

    2018-01-01

    Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials.

  16. Comparing performance on the MNREAD iPad application with the MNREAD acuity chart

    PubMed Central

    Calabrèse, Aurélie; To, Long; He, Yingchen; Berkholtz, Elizabeth; Rafian, Paymon; Legge, Gordon E.

    2018-01-01

    Our purpose was to compare reading performance measured with the MNREAD Acuity Chart and an iPad application (app) version of the same test for both normally sighted and low-vision participants. Our methods included 165 participants with normal vision and 43 participants with low vision tested on the standard printed MNREAD and on the iPad app version of the test. Maximum Reading Speed, Critical Print Size, Reading Acuity, and Reading Accessibility Index were compared using linear mixed-effects models to identify any potential differences in test performance between the printed chart and the iPad app. Our results showed the following: For normal vision, chart and iPad yield similar estimates of Critical Print Size and Reading Acuity. The iPad provides significantly slower estimates of Maximum Reading Speed than the chart, with a greater difference for faster readers. The difference was on average 3% at 100 words per minute (wpm), 6% at 150 wpm, 9% at 200 wpm, and 12% at 250 wpm. For low vision, Maximum Reading Speed, Reading Accessibility Index, and Critical Print Size are equivalent on the iPad and chart. Only the Reading Acuity is significantly smaller (I. E., better) when measured on the digital version of the test, but by only 0.03 logMAR (p = 0.013). Our conclusions were that, overall, MNREAD parameters measured with the printed chart and the iPad app are very similar. The difference found in Maximum Reading Speed for the normally sighted participants can be explained by differences in the method for timing the reading trials. PMID:29351351

  17. Quantum criticality in the spin-1/2 Heisenberg chain system copper pyrazine dinitrate

    PubMed Central

    Breunig, Oliver; Garst, Markus; Klümper, Andreas; Rohrkamp, Jens; Turnbull, Mark M.; Lorenz, Thomas

    2017-01-01

    Low-dimensional quantum magnets promote strong correlations between magnetic moments that lead to fascinating quantum phenomena. A particularly interesting system is the antiferromagnetic spin-1/2 Heisenberg chain because it is exactly solvable by the Bethe-Ansatz method. It is approximately realized in the magnetic insulator copper pyrazine dinitrate, providing a unique opportunity for a quantitative comparison between theory and experiment. We investigate its thermodynamic properties with a particular focus on the field-induced quantum phase transition. Thermal expansion, magnetostriction, specific heat, magnetization, and magnetocaloric measurements are found to be in excellent agreement with exact Bethe-Ansatz predictions. Close to the critical field, thermodynamics obeys the expected quantum critical scaling behavior, and in particular, the magnetocaloric effect and the Grüneisen parameters diverge in a characteristic manner. Beyond its importance for quantum magnetism, our study establishes a paradigm of a quantum phase transition, which illustrates fundamental principles of quantum critical thermodynamics. PMID:29282449

  18. CD-measurement technique for hole patterns on stencil mask

    NASA Astrophysics Data System (ADS)

    Ishikawa, Mikio; Yusa, Satoshi; Takikawa, Tadahiko; Fujita, Hiroshi; Sano, Hisatake; Hoga, Morihisa; Hayashi, Naoya

    2004-12-01

    EB lithography has a potential to successfully form hole patterns as small as 80 nm with a stencil mask. In a previous paper we proposed a technique using a HOLON dual-mode critical dimension (CD) SEM ESPA-75S in the transmission mode for CD measurement of line-and-space patterns on a stencil mask. In this paper we extend our effort of developing a CD measurement technique to contact hole features and determine it in comparison of measured values between features on mask and those printed on wafer. We have evaluated the width method and the area methods using designed 80-500 nm wide contact hole patterns on a large area membrane mask and their resist images on wafer printed by a LEEPL3000. We find that 1) the width method and the area methods show an excellent mask-wafer correlation for holes over 110 nm, and 2) the area methods show a better mask-wafer correlation than the width method does for holes below 110 nm. We conclude that the area calculated from the transmission SEM image is more suitable in defining the hole dimensions than the width for contact holes on a stencil mask.

  19. Magnetocaloric effect and critical field analysis in Eu substituted La0.7-xEuxSr0.3MnO3 (x = 0.0, 0.1, 0.2, 0.3) manganites

    NASA Astrophysics Data System (ADS)

    Vadnala, Sudharshan; Asthana, Saket

    2018-01-01

    In this study, we have investigated magnetic behavior, magnetocaloric effect and critical exponent analysis of La0.7-xEuxSr0.3MnO3 (x = 0.0, 0.1, 0.2, 0.3) manganites synthesized through solid state reaction route. The crystallographic data obtained from refinement of X-ray diffraction patterns reveal that crystal structure changes from rhombohedral (for x = 0.0) to orthorhombic (for x ≥ 0.1). The average ionic radius of A-site is decreased from 1.384 Å (for x = 0.0) to 1.360 Å (for x = 0.3) with Eu3+ substitution which in turn decreases the Mn-O-Mn bond angles. Magnetization measurements are performed in the vicinity of TC to determine magnetocaloric effect (MCE) and critical field behavior. The maximum magnetic entropy change (Δ SMmax) (for μ0ΔH = 6T) increases with the Eu3+ substitution from 3.88 J/kg K (for x = 0.0) to 5.03 J/kg K (for x = 0.3) at the transition temperature. The critical field behaviour of compounds was analysed using various methods such as modified Arrott plots, Kouvel-Fisher method and critical isotherm to determine critical temperature and critical exponents (β, γ and δ). The obtained critical exponents are in good accordance with scaling relation. The temperature dependence of the order parameter n, for different magnetic fields, is studied using the relation ΔSMαHn. The values of n are found to obey the Curie-Weiss law for temperatures above the transition temperature. The rescaled change in entropy data for all compounds collapses into the same universal curve, revealing a second order phase transition.

  20. Identification of the students' critical thinking skills through biochemistry laboratory work report

    NASA Astrophysics Data System (ADS)

    Anwar, Yunita Arian Sani; Senam, Laksono, Endang W.

    2017-08-01

    This work aims to (1) identify the critical thinking skills of student based on their ability to set up laboratory work reports, and (2) analyze the implementation of biochemistry laboratory work. The method of quantitative content analysis was employed. Quantitative data were in the form of critical thinking skills through the assessment of students' laboratory work reports and questionnaire data. Hoyo rubric was used to measure critical thinking skills with 10 indicators, namely clarity, accuracy, precision, consistency, relevance, evidence, reason, depth, breadth, and fairness. The research sample consisted of 105 students (35 male, 70 female) of Mataram University who took a Biochemistry course and 2 lecturers of Biochemistry course. The results showed students' critical thinking skills through laboratory work reports were still weak. Analysis of the questionnaire showed that three indicators become the biggest problems during the laboratory work implementation, namely, lecturers' involved in laboratory work implementation, the integration of laboratory work implementation of learning in the classroom has not been done optimally and laboratory work implementation as an effort to train critical thinking skills is not optimal yet.

  1. Measuring quality in anatomic pathology.

    PubMed

    Raab, Stephen S; Grzybicki, Dana Marie

    2008-06-01

    This article focuses mainly on diagnostic accuracy in measuring quality in anatomic pathology, noting that measuring any quality metric is complex and demanding. The authors discuss standardization and its variability within and across areas of care delivery and efforts involving defining and measuring error to achieve pathology quality and patient safety. They propose that data linking error to patient outcome are critical for developing quality improvement initiatives targeting errors that cause patient harm in addition to using methods of root cause analysis, beyond those traditionally used in cytologic-histologic correlation, to assist in the development of error reduction and quality improvement plans.

  2. Energy Measurement Studies for CO2 Measurement with a Coherent Doppler Lidar System

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.; Vanvalkenburg, Randal L.; Yu, Jirong; Singh, Upendra N.; Kavaya, Michael J.

    2010-01-01

    The accurate measurement of energy in the application of lidar system for CO2 measurement is critical. Different techniques of energy estimation in the online and offline pulses are investigated for post processing of lidar returns. The cornerstone of the techniques is the accurate estimation of the spectrum of lidar signal and background noise. Since the background noise is not the ideal white Gaussian noise, simple average level estimation of noise level is not well fit in the energy estimation of lidar signal and noise. A brief review of the methods is presented in this paper.

  3. Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ling, Xue; Wang, Yusheng; Li, Xide, E-mail: lixide@tsinghua.edu.cn

    An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects ofmore » the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li–Etsion–Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.« less

  4. Precise and traceable carbon isotope ratio measurements by multicollector ICP-MS: what next?

    PubMed

    Santamaria-Fernandez, Rebeca

    2010-06-01

    This article reviews recent developments in the use of multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) to provide high-precision carbon isotope ratio measurements. MC-ICP-MS could become an alternative method to isotope ratio mass spectrometry (IRMS) for rapid carbon isotope ratio determinations in organic compounds and characterisation and certification of isotopic reference materials. In this overview, the advantages, drawbacks and potential of the method for future applications are critically discussed. Furthermore, suggestions for future improvements in terms of precision and sensitivity are made. No doubt, this is an exciting analytical challenge and, as such, hurdles will need to be cleared.

  5. Pure phase encode magnetic field gradient monitor.

    PubMed

    Han, Hui; MacGregor, Rodney P; Balcom, Bruce J

    2009-12-01

    Numerous methods have been developed to measure MRI gradient waveforms and k-space trajectories. The most promising new strategy appears to be magnetic field monitoring with RF microprobes. Multiple RF microprobes may record the magnetic field evolution associated with a wide variety of imaging pulse sequences. The method involves exciting one or more test samples and measuring the time evolution of magnetization through the FIDs. Two critical problems remain. The gradient waveform duration is limited by the sample T(2)*, while the k-space maxima are limited by gradient dephasing. The method presented is based on pure phase encode FIDs and solves the above two problems in addition to permitting high strength gradient measurement. A small doped water phantom (1-3 mm droplet, T(1), T(2), T(2)* < 100 micros) within a microprobe is excited by a series of closely spaced broadband RF pulses each followed by FID single point acquisition. Two trial gradient waveforms have been chosen to illustrate the technique, neither of which could be measured by the conventional RF microprobe measurement. The first is an extended duration gradient waveform while the other illustrates the new method's ability to measure gradient waveforms with large net area and/or high amplitude. The new method is a point monitor with simple implementation and low cost hardware requirements.

  6. A fast and accurate surface plasmon resonance system

    NASA Astrophysics Data System (ADS)

    Espinosa Sánchez, Y. M.; Luna Moreno, D.; Noé Arias, E.; Garnica Campos, G.

    2012-10-01

    In this work we propose a Surface Plasmon Resonance (SPR) system driven by Labview software which produces a fast, simple and accuracy measurements of samples. The system takes 2000 data in a range of 20 degrees in 20 seconds and 0.01 degrees of resolution. All the information is sent from the computer to the microcontroller as an array of bytes in hexadecimal format to be analyzed. Besides to using the system in SPR measurement is possible to make measurement of the critic angle, and Brewster angle using the Abeles method.

  7. Complex motion measurement using genetic algorithm

    NASA Astrophysics Data System (ADS)

    Shen, Jianjun; Tu, Dan; Shen, Zhenkang

    1997-12-01

    Genetic algorithm (GA) is an optimization technique that provides an untraditional approach to deal with many nonlinear, complicated problems. The notion of motion measurement using genetic algorithm arises from the fact that the motion measurement is virtually an optimization process based on some criterions. In the paper, we propose a complex motion measurement method using genetic algorithm based on block-matching criterion. The following three problems are mainly discussed and solved in the paper: (1) apply an adaptive method to modify the control parameters of GA that are critical to itself, and offer an elitism strategy at the same time (2) derive an evaluate function of motion measurement for GA based on block-matching technique (3) employ hill-climbing (HC) method hybridly to assist GA's search for the global optimal solution. Some other related problems are also discussed. At the end of paper, experiments result is listed. We employ six motion parameters for measurement in our experiments. Experiments result shows that the performance of our GA is good. The GA can find the object motion accurately and rapidly.

  8. Recommendations for a mixed methods approach to evaluating the patient-centered medical home.

    PubMed

    Goldman, Roberta E; Parker, Donna R; Brown, Joanna; Walker, Judith; Eaton, Charles B; Borkan, Jeffrey M

    2015-03-01

    There is a strong push in the United States to evaluate whether the patient-centered medical home (PCMH) model produces desired results. The explanatory and contextually based questions of how and why PCMH succeeds in different practice settings are often neglected. We report the development of a comprehensive, mixed qualitative-quantitative evaluation set for researchers, policy makers, and clinician groups. To develop an evaluation set, the Brown Primary Care Transformation Initiative convened a multidisciplinary group of PCMH experts, reviewed the PCMH literature and evaluation strategies, developed key domains for evaluation, and selected or created methods and measures for inclusion. The measures and methods in the evaluation set (survey instruments, PCMH meta-measures, patient outcomes, quality measures, qualitative interviews, participant observation, and process evaluation) are meant to be used together. PCMH evaluation must be sufficiently comprehensive to assess and explain both the context of transformation in different primary care practices and the experiences of diverse stakeholders. In addition to commonly assessed patient outcomes, quality, and cost, it is critical to include PCMH components integral to practice culture transformation: patient and family centeredness, authentic patient activation, mutual trust among practice employees and patients, and transparency, joy, and collaboration in delivering and receiving care in a changing environment. This evaluation set offers a comprehensive methodology to enable understanding of how PCMH transformation occurs in different practice settings. This approach can foster insights about how transformation affects critical outcomes to achieve meaningful, patient-centered, high-quality, and cost-effective sustainable change among diverse primary care practices. © 2015 Annals of Family Medicine, Inc.

  9. Fast and precise dense grid size measurement method based on coaxial dual optical imaging system

    NASA Astrophysics Data System (ADS)

    Guo, Jiping; Peng, Xiang; Yu, Jiping; Hao, Jian; Diao, Yan; Song, Tao; Li, Ameng; Lu, Xiaowei

    2015-10-01

    Test sieves with dense grid structure are widely used in many fields, accurate gird size calibration is rather critical for success of grading analysis and test sieving. But traditional calibration methods suffer from the disadvantages of low measurement efficiency and shortage of sampling number of grids which could lead to quality judgment risk. Here, a fast and precise test sieve inspection method is presented. Firstly, a coaxial imaging system with low and high optical magnification probe is designed to capture the grid images of the test sieve. Then, a scaling ratio between low and high magnification probes can be obtained by the corresponding grids in captured images. With this, all grid dimensions in low magnification image can be obtained by measuring few corresponding grids in high magnification image with high accuracy. Finally, by scanning the stage of the tri-axis platform of the measuring apparatus, whole surface of the test sieve can be quickly inspected. Experiment results show that the proposed method can measure the test sieves with higher efficiency compare to traditional methods, which can measure 0.15 million grids (gird size 0.1mm) within only 60 seconds, and it can measure grid size range from 20μm to 5mm precisely. In a word, the presented method can calibrate the grid size of test sieve automatically with high efficiency and accuracy. By which, surface evaluation based on statistical method can be effectively implemented, and the quality judgment will be more reasonable.

  10. Variation of organic matter quantity and quality in streams at Critical Zone Observatory watersheds

    USGS Publications Warehouse

    Miller, Matthew P.; Boyer, Elizabeth W.; McKnight, Diane M.; Brown, Michael G.; Gabor, Rachel S.; Hunsaker, Carolyn T.; Iavorivska , Lidiia; Inamdar, Shreeram; Kaplan, Louis A.; Johnson, Dale W.; Lin, Henry; McDowell, William H.; Perdrial, Julia N.

    2016-01-01

    The quantity and chemical composition of dissolved organic matter (DOM) in surface waters influence ecosystem processes and anthropogenic use of freshwater. However, despite the importance of understanding spatial and temporal patterns in DOM, measures of DOM quality are not routinely included as part of large-scale ecosystem monitoring programs and variations in analytical procedures can introduce artifacts. In this study, we used consistent sampling and analytical methods to meet the objective of defining variability in DOM quantity and quality and other measures of water quality in streamflow issuing from small forested watersheds located within five Critical Zone Observatory sites representing contrasting environmental conditions. Results show distinct separations among sites as a function of water quality constituents. Relationships among rates of atmospheric deposition, water quality conditions, and stream DOM quantity and quality are consistent with the notion that areas with relatively high rates of atmospheric nitrogen and sulfur deposition and high concentrations of divalent cations result in selective transport of DOM derived from microbial sources, including in-stream microbial phototrophs. We suggest that the critical zone as a whole strongly influences the origin, composition, and fate of DOM in streams. This study highlights the value of consistent DOM characterization methods included as part of long-term monitoring programs for improving our understanding of interactions among ecosystem processes as controls on DOM biogeochemistry.

  11. Novel X-ray Communication Based XNAV Augmentation Method Using X-ray Detectors

    PubMed Central

    Song, Shibin; Xu, Luping; Zhang, Hua; Bai, Yuanjie

    2015-01-01

    The further development of X-ray pulsar-based NAVigation (XNAV) is hindered by its lack of accuracy, so accuracy improvement has become a critical issue for XNAV. In this paper, an XNAV augmentation method which utilizes both pulsar observation and X-ray ranging observation for navigation filtering is proposed to deal with this issue. As a newly emerged concept, X-ray communication (XCOM) shows great potential in space exploration. X-ray ranging, derived from XCOM, could achieve high accuracy in range measurement, which could provide accurate information for XNAV. For the proposed method, the measurement models of pulsar observation and range measurement observation are established, and a Kalman filtering algorithm based on the observations and orbit dynamics is proposed to estimate the position and velocity of a spacecraft. A performance comparison of the proposed method with the traditional pulsar observation method is conducted by numerical experiments. Besides, the parameters that influence the performance of the proposed method, such as the pulsar observation time, the SNR of the ranging signal, etc., are analyzed and evaluated by numerical experiments. PMID:26404295

  12. The role of atomic absorption spectrometry in geochemical exploration

    USGS Publications Warehouse

    Viets, J.G.; O'Leary, R. M.

    1992-01-01

    In this paper we briefly describe the principles of atomic absorption spectrometry (AAS) and the basic hardware components necessary to make measurements of analyte concentrations. Then we discuss a variety of methods that have been developed for the introduction of analyte atoms into the light path of the spectrophotometer. This section deals with sample digestion, elimination of interferences, and optimum production of ground-state atoms, all critical considerations when choosing an AAS method. Other critical considerations are cost, speed, simplicity, precision, and applicability of the method to the wide range of materials sampled in geochemical exploration. We cannot attempt to review all of the AAS methods developed for geological materials but instead will restrict our discussion to some of those appropriate for geochemical exploration. Our background and familiarity are reflected in the methods we discuss, and we have no doubt overlooked many good methods. Our discussion should therefore be considered a starting point in finding the right method for the problem, rather than the end of the search. Finally, we discuss the future of AAS relative to other instrumental techniques and the promising new directions for AAS in geochemical exploration. ?? 1992.

  13. A Hydrologically-based Method for Calculating Sustainable Yield under California's Sustainable Groundwater Management Act

    NASA Astrophysics Data System (ADS)

    Miro, M.; Famiglietti, J. S.

    2016-12-01

    In California, traditional water management has focused heavily on surface water, leaving many basins in a state of critical overdraft and lacking in established frameworks for groundwater management. However, new groundwater legislation, the 2014 Sustainable Groundwater Management Act (SGMA), presents an important opportunity for water managers and hydrologists to develop novel methods for managing statewide groundwater resources. Integrating scientific advances in groundwater monitoring with hydrologically-sound methods can go a long way in creating a system that can better govern the resource. SGMA mandates that groundwater management agencies employ the concept of sustainable yield as their primary management goal but does not clearly define a method to calculate it. This study will develop a hydrologically-based method to quantify sustainable yield that follows the threshold framework under SGMA. Using this method, sustainable yield will be calculated for two critically-overdrafted groundwater basins in California's Central Valley. This measure will also utilize groundwater monitoring data and downscaled remote sensing estimates of groundwater storage change from NASA's GRACE satellite to illustrate why data matters for successful management. This method can be used as a basis for the development of SGMA's groundwater management plans (GSPs) throughout California.

  14. Blood Glucose Measurement in the Intensive Care Unit: What Is the Best Method?

    PubMed Central

    Le, Huong T.; Harris, Neil S.; Estilong, Abby J.; Olson, Arvid; Rice, Mark J.

    2013-01-01

    Abnormal glucose measurements are common among intensive care unit (ICU) patients for numerous reasons and hypoglycemia is especially dangerous because these patients are often sedated and unable to relate the associated symptoms. Additionally, wide swings in blood glucose have been closely tied to increased mortality. Therefore, accurate and timely glucose measurement in this population is critical. Clinicians have several choices available to assess blood glucose values in the ICU, including central laboratory devices, blood gas analyzers, and point-of-care meters. In this review, the method of glucose measurement will be reviewed for each device, and the important characteristics, including accuracy, cost, speed of result, and sample volume, will be reviewed, specifically as these are used in the ICU environment. Following evaluation of the individual measurement devices and after considering the many features of each, recommendations are made for optimal ICU glucose determination. PMID:23567008

  15. Optical coherence refractometry.

    PubMed

    Tomlins, Peter H; Woolliams, Peter; Hart, Christian; Beaumont, Andrew; Tedaldi, Matthew

    2008-10-01

    We introduce a novel approach to refractometry using a low coherence interferometer at multiple angles of incidence. We show that for plane parallel samples it is possible to measure their phase refractive index rather than the group index that is usually measured by interferometric methods. This is a significant development because it enables bulk refractive index measurement of scattering and soft samples, not relying on surface measurements that can be prone to error. Our technique is also noncontact and compatible with in situ refractive index measurements. Here, we demonstrate this new technique on a pure silica test piece and a highly scattering resin slab, comparing the results with standard critical angle refractometry.

  16. Correcting Measurement Error in Latent Regression Covariates via the MC-SIMEX Method

    ERIC Educational Resources Information Center

    Rutkowski, Leslie; Zhou, Yan

    2015-01-01

    Given the importance of large-scale assessments to educational policy conversations, it is critical that subpopulation achievement is estimated reliably and with sufficient precision. Despite this importance, biased subpopulation estimates have been found to occur when variables in the conditioning model side of a latent regression model contain…

  17. Non-Invasive Acoustic-Based Monitoring of Heavy Water and Uranium Process Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pantea, Cristian; Sinha, Dipen N.; Lakis, Rollin Evan

    2017-11-02

    The goals of the project are to leverage laboratory scientific strength in physical acoustics for critical international safeguards applications; create hardware demonstration capability for noninvasive, near real time, and low cost process monitor to capture future technology development programs; and measure physical property data to support method applicability.

  18. Using Interactive Multimedia to Teach Pedestrian Safety: An Exploratory Study

    ERIC Educational Resources Information Center

    Glang, Ann; Noell, John; Ary, Dennis; Swartz, Lynne

    2005-01-01

    Objectives: To evaluate an interactive multimedia (IMM) program that teaches young children safe pedestrian skills. Methods: The program uses IMM (animation and video) to teach children critical skills for crossing streets safely. A computer-delivered video assessment and a real-life street simulation were used to measure the effectiveness of the…

  19. How Can We Improve the Measurement of "Non-Academic" Competencies?

    ERIC Educational Resources Information Center

    Halpin, Peter F.

    2017-01-01

    The target paper, "Rethinking Traditional Methods of Survey Validation" (Andrew Maul), raises some interesting critical ideas, both old and new, about the validation of self-report surveys. As indicated by Dr. Maul, recent policy initiatives in the United States (e.g., ESSA) have led to a demand for assessments of…

  20. Validating the Alcohol Use Disorders Identification Test with Persons Who Have a Serious Mental Illness

    ERIC Educational Resources Information Center

    O'Hare, Thomas; Sherrer, Margaret V.; LaButti, Annamaria; Emrick, Kelly

    2004-01-01

    Objective/Method: The use of brief, reliable, valid, and practical measures of substance use is critical for conducting individual assessments and program evaluation for integrated mental health-substance abuse services for persons with serious mental illness. This investigation examines the internal consistency reliability, concurrent validity,…

  1. Chinese Secondary Physical Education Teachers' Depth of Specialized Content Knowledge in Soccer

    ERIC Educational Resources Information Center

    Ward, Phillip; He, Yaohui; Wang, Xiaozan; Li, Weidong

    2018-01-01

    Purpose: Accurately measuring the content knowledge of teachers is critical to designing professional development to support their teaching. We examined the depth of specialized content knowledge (SCK), defined in terms of instructional tasks reported by teachers and factors that could affect their SCK. Method: Content maps were used to evaluate…

  2. Executive Functions: Formative versus Reflective Measurement

    ERIC Educational Resources Information Center

    Willoughby, Michael; Holochwost, Steven J.; Blanton, Zane E.; Blair, Clancy B.

    2014-01-01

    The primary objective of this article was to critically evaluate the routine use of confirmatory factor analysis (CFA) for representing an individual's performance across a battery of executive function tasks. A conceptual review and statistical reanalysis of N = 10 studies that used CFA methods of EF tasks was undertaken. Despite evidence of…

  3. Measuring Reading Instruction with Teacher Logs

    ERIC Educational Resources Information Center

    Rowan, Brian; Correnti, Richard

    2009-01-01

    The authors argue that the criticisms of their earlier article on teacher logs ("Educational Researcher," March 2009) by Smagorinsky and Willis do not address, much less undermine, the evidence they presented as part of their validation argument about the teacher logs. Moreover, they argue that their method for studying classrooms is not nearly as…

  4. Using the DASH Method to Measure Reading Comprehension

    ERIC Educational Resources Information Center

    Shieh, Wenyuh; Freiermuth, Mark R.

    2010-01-01

    Vocabulary knowledge has been recognized by researchers as a critical component of reading comprehension, not only as a means to facilitate first language acquisition but also as an integral element in the learning of English as a second or foreign language. To reduce the effect of insufficient vocabulary knowledge during reading, a compensatory…

  5. Method development and validation for measuring the particle size distribution of pentaerythritol tetranitrate (PETN) powders.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, Sharissa Gay

    2005-09-01

    Currently, the critical particle properties of pentaerythritol tetranitrate (PETN) that influence deflagration-to-detonation time in exploding bridge wire detonators (EBW) are not known in sufficient detail to allow development of a predictive failure model. The specific surface area (SSA) of many PETN powders has been measured using both permeametry and gas absorption methods and has been found to have a critical effect on EBW detonator performance. The permeametry measure of SSA is a function of particle shape, packed bed pore geometry, and particle size distribution (PSD). Yet there is a general lack of agreement in PSD measurements between laboratories, raising concernsmore » regarding collaboration and complicating efforts to understand changes in EBW performance related to powder properties. Benchmarking of data between laboratories that routinely perform detailed PSD characterization of powder samples and the determination of the most appropriate method to measure each PETN powder are necessary to discern correlations between performance and powder properties and to collaborate with partnering laboratories. To this end, a comparison was made of the PSD measured by three laboratories using their own standard procedures for light scattering instruments. Three PETN powder samples with different surface areas and particle morphologies were characterized. Differences in bulk PSD data generated by each laboratory were found to result from variations in sonication of the samples during preparation. The effect of this sonication was found to depend on particle morphology of the PETN samples, being deleterious to some PETN samples and advantageous for others in moderation. Discrepancies in the submicron-sized particle characterization data were related to an instrument-specific artifact particular to one laboratory. The type of carrier fluid used by each laboratory to suspend the PETN particles for the light scattering measurement had no consistent effect on the resulting PSD data. Finally, the SSA of the three powders was measured using both permeametry and gas absorption methods, enabling the PSD to be linked to the SSA for these PETN powders. Consistent characterization of other PETN powders can be performed using the appropriate sample-specific preparation method, so that future studies can accurately identify the effect of changes in the PSD on the SSA and ultimately model EBW performance.« less

  6. Animal models of post-ischemic forced use rehabilitation: methods, considerations, and limitations

    PubMed Central

    2013-01-01

    Many survivors of stroke experience arm impairments, which can severely impact their quality of life. Forcing use of the impaired arm appears to improve functional recovery in post-stroke hemiplegic patients, however the mechanisms underlying improved recovery remain unclear. Animal models of post-stroke rehabilitation could prove critical to investigating such mechanisms, however modeling forced use in animals has proven challenging. Potential problems associated with reported experimental models include variability between stroke methods, rehabilitation paradigms, and reported outcome measures. Herein, we provide an overview of commonly used stroke models, including advantages and disadvantages of each with respect to studying rehabilitation. We then review various forced use rehabilitation paradigms, and highlight potential difficulties and translational problems. Lastly, we discuss the variety of functional outcome measures described by experimental researchers. To conclude, we outline ongoing challenges faced by researchers, and the importance of translational communication. Many stroke patients rely critically on rehabilitation of post-stroke impairments, and continued effort toward progression of rehabilitative techniques is warranted to ensure best possible treatment of the devastating effects of stroke. PMID:23343500

  7. Automated inspection of gaps on the free-form shape parts by laser scanning technologies

    NASA Astrophysics Data System (ADS)

    Zhou, Sen; Xu, Jian; Tao, Lei; An, Lu; Yu, Yan

    2018-01-01

    In industrial manufacturing processes, the dimensional inspection of the gaps on the free-form shape parts is critical and challenging, and is directly associated with subsequent assembly and terminal product quality. In this paper, a fast measuring method for automated gap inspection based on laser scanning technologies is presented. The proposed measuring method consists of three steps: firstly, the relative position is determined according to the geometric feature of measuring gap, which considers constraints existing in a laser scanning operation. Secondly, in order to acquire a complete gap profile, a fast and effective scanning path is designed. Finally, the range dimension of the gaps on the free-form shape parts including width, depth and flush, correspondingly, is described in a virtual environment. In the future, an appliance machine based on the proposed method will be developed for the on-line dimensional inspection of gaps on the automobile or aerospace production line.

  8. Real-Time Phase Correction Based on FPGA in the Beam Position and Phase Measurement System

    NASA Astrophysics Data System (ADS)

    Gao, Xingshun; Zhao, Lei; Liu, Jinxin; Jiang, Zouyi; Hu, Xiaofang; Liu, Shubin; An, Qi

    2016-12-01

    A fully digital beam position and phase measurement (BPPM) system was designed for the linear accelerator (LINAC) in Accelerator Driven Sub-critical System (ADS) in China. Phase information is obtained from the summed signals from four pick-ups of the Beam Position Monitor (BPM). Considering that the delay variations of different analog circuit channels would introduce phase measurement errors, we propose a new method to tune the digital waveforms of four channels before summation and achieve real-time error correction. The process is based on the vector rotation method and implemented within one single Field Programmable Gate Array (FPGA) device. Tests were conducted to evaluate this correction method and the results indicate that a phase correction precision better than ± 0.3° over the dynamic range from -60 dBm to 0 dBm is achieved.

  9. Shallow Reflection Method for Water-Filled Void Detection and Characterization

    NASA Astrophysics Data System (ADS)

    Zahari, M. N. H.; Madun, A.; Dahlan, S. H.; Joret, A.; Hazreek, Z. A. M.; Mohammad, A. H.; Izzaty, R. A.

    2018-04-01

    Shallow investigation is crucial in enhancing the characteristics of subsurface void commonly encountered in civil engineering, and one such technique commonly used is seismic-reflection technique. An assessment of the effectiveness of such an approach is critical to determine whether the quality of the works meets the prescribed requirements. Conventional quality testing suffers limitations including: limited coverage (both area and depth) and problems with resolution quality. Traditionally quality assurance measurements use laboratory and in-situ invasive and destructive tests. However geophysical approaches, which are typically non-invasive and non-destructive, offer a method by which improvement of detection can be measured in a cost-effective way. Of this seismic reflection have proved useful to assess void characteristic, this paper evaluates the application of shallow seismic-reflection method in characterizing the water-filled void properties at 0.34 m depth, specifically for detection and characterization of void measurement using 2-dimensional tomography.

  10. Enthalpy By Energy Balance for Aerodynamic Heating Facility at NASA Ames Research Center Arc Jet Complex

    NASA Technical Reports Server (NTRS)

    Hightower, T. Mark; MacDonald, Christine L.; Martinez, Edward R.; Balboni, John A.; Anderson, Karl F.; Arnold, Jim O. (Technical Monitor)

    2002-01-01

    The NASA Ames Research Center (ARC) Arc Jet Facilities' Aerodynamic Heating Facility (AHF) has been instrumented for the Enthalpy By Energy Balance (EB2) method. Diagnostic EB2 data is routinely taken for all AHF runs. This paper provides an overview of the EB2 method implemented in the AHF. The chief advantage of the AHF implementation over earlier versions is the non-intrusiveness of the instruments used. For example, to measure the change in cooling water temperature, thin film 1000 ohm Resistance Temperature Detectors (RTDs) are used with an Anderson Current Loop (ACL) as the signal conditioner. The ACL with 1000 ohm RTDs allows for very sensitive measurement of the increase in temperature (Delta T) of the cooling water to the arc heater, which is a critical element of the EB2 method. Cooling water flow rates are measured with non-intrusive ultrasonic flow meters.

  11. Close-Range Photogrammetry & Next Generation Spacecraft

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.

    2002-01-01

    NASA is focusing renewed attention on the topic of large, ultra-lightweight space structures, also known as 'gossamer' spacecraft. Nearly all of the details of the giant spacecraft are still to be worked out. But it's already clear that one of the most challenging aspects will be developing techniques to align and control these systems after they are deployed in space. A critical part of this process is creating new ground test methods to measure gossamer structures under stationary, deploying and vibrating conditions for validation of corresponding analytical predictions. In addressing this problem, I considered, first of all, the possibility of simply using conventional displacement or vibration sensor that could provide spatial measurements. Next, I turned my attention to photogrammetry, a method of determining the spatial coordinates of objects using photographs. The success of this research and development has convinced me that photogrammetry is the most suitable method to solve the gossamer measurement problem.

  12. Advanced Self-Potential Inversion. Development and Use for Investigating Natural Recharge Processes at the ORNL IFC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Revil, Andre

    2013-01-15

    Understanding the influence of coupled biological, chemical, and hydrological processes on subsurface contaminant behavior at multiple scales is a prerequisite for developing effective remedial approaches, whether they are active remediation or natural attenuation strategies. To develop this understanding, methods are needed that can measure critical components of the natural system in real time. The self-potential method corresponds to the passive measurement of the distribution of the electrical potential at the surface of the Earth or in boreholes. This method is very complemetary to other geophysical methods like DC resistivity and induced polarization. In this report, we summarize of research effortsmore » to advance the theory of low-frequency geoelectrical methods and their applications to the contaminant plumes in the vicinity of the former S-3 settling basins at Oak Ridge, TN.« less

  13. Recent trends in the determination of vitamin D.

    PubMed

    Gomes, Fabio P; Shaw, P Nicholas; Whitfield, Karen; Koorts, Pieter; Hewavitharana, Amitha K

    2013-12-01

    The occurrence of vitamin D deficiency has become an issue of serious concern in the worldwide population. As a result numerous analytical methods have been developed, for a variety of matrices, during the last few years to measure vitamin D analogs and metabolites. This review employs a comprehensive search of all vitamin D methods developed during the last 5 years for all applications, using ISI Web of Science(®), Scifinder(®), Science Direct, Scopus and PubMed. Particular emphasis is given to sample-preparation methods and the different forms of vitamin D measured across different fields of applications such as biological fluids, food and pharmaceutical preparations. This review compares and critically evaluates a wide range of approaches and methods, and hence it will enable readers to access developments across a number of applications and to select or develop the optimal analytical method for vitamin D for their particular application.

  14. Betweenness-Based Method to Identify Critical Transmission Sectors for Supply Chain Environmental Pressure Mitigation.

    PubMed

    Liang, Sai; Qu, Shen; Xu, Ming

    2016-02-02

    To develop industry-specific policies for mitigating environmental pressures, previous studies primarily focus on identifying sectors that directly generate large amounts of environmental pressures (a.k.a. production-based method) or indirectly drive large amounts of environmental pressures through supply chains (e.g., consumption-based method). In addition to those sectors as important environmental pressure producers or drivers, there exist sectors that are also important to environmental pressure mitigation as transmission centers. Economy-wide environmental pressure mitigation might be achieved by improving production efficiency of these key transmission sectors, that is, using less upstream inputs to produce unitary output. We develop a betweenness-based method to measure the importance of transmission sectors, borrowing the betweenness concept from network analysis. We quantify the betweenness of sectors by examining supply chain paths extracted from structural path analysis that pass through a particular sector. We take China as an example and find that those critical transmission sectors identified by betweenness-based method are not always identifiable by existing methods. This indicates that betweenness-based method can provide additional insights that cannot be obtained with existing methods on the roles individual sectors play in generating economy-wide environmental pressures. Betweenness-based method proposed here can therefore complement existing methods for guiding sector-level environmental pressure mitigation strategies.

  15. [Quality assessment in anesthesia].

    PubMed

    Kupperwasser, B

    1996-01-01

    Quality assessment (assurance/improvement) is the set of methods used to measure and improve the delivered care and the department's performance against pre-established criteria or standards. The four stages of the self-maintained quality assessment cycle are: problem identification, problem analysis, problem correction and evaluation of corrective actions. Quality assessment is a measurable entity for which it is necessary to define and calibrate measurement parameters (indicators) from available data gathered from the hospital anaesthesia environment. Problem identification comes from the accumulation of indicators. There are four types of quality indicators: structure, process, outcome and sentinel indicators. The latter signal a quality defect, are independent of outcomes, are easier to analyse by statistical methods and closely related to processes and main targets of quality improvement. The three types of methods to analyse the problems (indicators) are: peer review, quantitative methods and risks management techniques. Peer review is performed by qualified anaesthesiologists. To improve its validity, the review process should be explicited and conclusions based on standards of practice and literature references. The quantitative methods are statistical analyses applied to the collected data and presented in a graphic format (histogram, Pareto diagram, control charts). The risks management techniques include: a) critical incident analysis establishing an objective relationship between a 'critical' event and the associated human behaviours; b) system accident analysis, based on the fact that accidents continue to occur despite safety systems and sophisticated technologies, checks of all the process components leading to the impredictable outcome and not just the human factors; c) cause-effect diagrams facilitate the problem analysis in reducing its causes to four fundamental components (persons, regulations, equipment, process). Definition and implementation of corrective measures, based on the findings of the two previous stages, are the third step of the evaluation cycle. The Hawthorne effect is an outcome improvement, before the implementation of any corrective actions. Verification of the implemented actions is the final and mandatory step closing the evaluation cycle.

  16. Common method biases in behavioral research: a critical review of the literature and recommended remedies.

    PubMed

    Podsakoff, Philip M; MacKenzie, Scott B; Lee, Jeong-Yeon; Podsakoff, Nathan P

    2003-10-01

    Interest in the problem of method biases has a long history in the behavioral sciences. Despite this, a comprehensive summary of the potential sources of method biases and how to control for them does not exist. Therefore, the purpose of this article is to examine the extent to which method biases influence behavioral research results, identify potential sources of method biases, discuss the cognitive processes through which method biases influence responses to measures, evaluate the many different procedural and statistical techniques that can be used to control method biases, and provide recommendations for how to select appropriate procedural and statistical remedies for different types of research settings.

  17. Addressing challenges of modulation transfer function measurement with fisheye lens cameras

    NASA Astrophysics Data System (ADS)

    Deegan, Brian M.; Denny, Patrick E.; Zlokolica, Vladimir; Dever, Barry; Russell, Laura

    2015-03-01

    Modulation transfer function (MTF) is a well defined and accepted method of measuring image sharpness. The slanted edge test, as defined in ISO12233 is a standard method of calculating MTF, and is widely used for lens alignment and auto-focus algorithm verification. However, there are a number of challenges which should be considered when measuring MTF in cameras with fisheye lenses. Due to trade-offs related Petzval curvature, planarity of the optical plane is difficult to achieve in fisheye lenses. It is therefore critical to have the ability to accurately measure sharpness throughout the entire image, particularly for lens alignment. One challenge for fisheye lenses is that, because of the radial distortion, the slanted edges will have different angles, depending on the location within the image and on the distortion profile of the lens. Previous work in the literature indicates that MTF measurements are robust for angles between 2 and 10 degrees. Outside of this range, MTF measurements become unreliable. Also, the slanted edge itself will be curved by the lens distortion, causing further measurement problems. This study summarises the difficulties in the use of MTF for sharpness measurement in fisheye lens cameras, and proposes mitigations and alternative methods.

  18. WHAT DOESNT GET MEASURED - DOESNT GET DONE: IMPLEMENTING CONTINUOUS PROCESS IMPROVEMENT IN THE AIR FORCE RESERVE

    DTIC Science & Technology

    2016-04-01

    Practical Problem Solving Method RMD Resource Management Decision ROI Return on Investment SECAF Secretary of the Air Force SECNAV Secretary of...AFSO21 and now AF CPI, this program seeks to train and certify an organic cadre of CPI practitioners to support the use of its standard problem solving ...process known as the AF Practical Problem Solving Method (PPSM) to solve mission critical process deficiencies. The PPSM leverages several industry

  19. How to Measure Critical Health Competences: Development and Validation of the Critical Health Competence Test (CHC Test)

    ERIC Educational Resources Information Center

    Steckelberg, Anke; Hulfenhaus, Christian; Kasper, Jurgen; Rost, Jurgen; Muhlhauser, Ingrid

    2009-01-01

    Consumers' autonomy regarding health increasingly requires competences to critically appraise health information. Critical health literacy refers to the concept of evidence-based medicine. Instruments to measure these competences in curriculum evaluation and surveys are lacking. We aimed to develop and validate an instrument to measure critical…

  20. A critical commentary on management science in relation to reforms after institutional National Health Service failures.

    PubMed

    Regan, Paul; Ball, Elaine

    2017-03-01

    A discussion paper on the United Kingdom (UK) National Health Service (NHS) market reforms. NHS market reforms reliance on management science methods introduced a fundamental shift in measuring care for commissioning. A number of key reports are discussed in relation to NHS market reforms and management science. NHS market reforms were influenced through a close alliance between policy makers, the department of health, free market think tanks and management consultancies. The timing of reforms coincided with reports on NHS failings and the evolution of measurement methods to focus on finance. The balance in favour of measurement practises is of concern. Management science methods are criticised in the Francis Report yet promoted as the solution to some of the key findings; why may be explained by the close alliance. A return to principles of management involving consensus, trust and involvement to promote quality care and use management science methods to this end. © 2016 John Wiley & Sons Ltd.

  1. Effect of analytical conditions in wavelength dispersive electron microprobe analysis on the measurement of strontium-to-calcium (Sr/Ca) ratios in otoliths of anadromous salmonids

    USGS Publications Warehouse

    Zimmerman, Christian E.; Nielsen, Roger L.

    2003-01-01

    The use of strontium-to-calcium (Sr/Ca) ratios in otoliths is becoming a standard method to describe life history type and the chronology of migrations between freshwater and seawater habitats in teleosts (e.g. Kalish, 1990; Radtke et al., 1990; Secor, 1992; Rieman et al., 1994; Radtke, 1995; Limburg, 1995; Tzeng et al. 1997; Volk et al., 2000; Zimmerman, 2000; Zimmerman and Reeves, 2000, 2002). This method provides critical information concerning the relationship and ecology of species exhibiting phenotypic variation in migratory behavior (Kalish, 1990; Secor, 1999). Methods and procedures, however, vary among laboratories because a standard method or protocol for measurement of Sr in otoliths does not exist. In this note, we examine the variations in analytical conditions in an effort to increase precision of Sr/Ca measurements. From these findings we argue that precision can be maximized with higher beam current (although there is specimen damage) than previously recommended by Gunn et al. (1992).

  2. Complexity-Entropy Causality Plane as a Complexity Measure for Two-Dimensional Patterns

    PubMed Central

    Ribeiro, Haroldo V.; Zunino, Luciano; Lenzi, Ervin K.; Santoro, Perseu A.; Mendes, Renio S.

    2012-01-01

    Complexity measures are essential to understand complex systems and there are numerous definitions to analyze one-dimensional data. However, extensions of these approaches to two or higher-dimensional data, such as images, are much less common. Here, we reduce this gap by applying the ideas of the permutation entropy combined with a relative entropic index. We build up a numerical procedure that can be easily implemented to evaluate the complexity of two or higher-dimensional patterns. We work out this method in different scenarios where numerical experiments and empirical data were taken into account. Specifically, we have applied the method to fractal landscapes generated numerically where we compare our measures with the Hurst exponent; liquid crystal textures where nematic-isotropic-nematic phase transitions were properly identified; 12 characteristic textures of liquid crystals where the different values show that the method can distinguish different phases; and Ising surfaces where our method identified the critical temperature and also proved to be stable. PMID:22916097

  3. Surface fractal dimension, water adsorption efficiency, and cloud nucleation activity of insoluble aerosol.

    PubMed

    Laaksonen, Ari; Malila, Jussi; Nenes, Athanasios; Hung, Hui-Ming; Chen, Jen-Ping

    2016-05-03

    Surface porosity affects the ability of a substance to adsorb gases. The surface fractal dimension D is a measure that indicates the amount that a surface fills a space, and can thereby be used to characterize the surface porosity. Here we propose a new method for determining D, based on measuring both the water vapour adsorption isotherm of a given substance, and its ability to act as a cloud condensation nucleus when introduced to humidified air in aerosol form. We show that our method agrees well with previous methods based on measurement of nitrogen adsorption. Besides proving the usefulness of the new method for general surface characterization of materials, our results show that the surface fractal dimension is an important determinant in cloud drop formation on water insoluble particles. We suggest that a closure can be obtained between experimental critical supersaturation for cloud drop activation and that calculated based on water adsorption data, if the latter is corrected using the surface fractal dimension of the insoluble cloud nucleus.

  4. Surface fractal dimension, water adsorption efficiency, and cloud nucleation activity of insoluble aerosol

    NASA Astrophysics Data System (ADS)

    Laaksonen, Ari; Malila, Jussi; Nenes, Athanasios; Hung, Hui-Ming; Chen, Jen-Ping

    2016-05-01

    Surface porosity affects the ability of a substance to adsorb gases. The surface fractal dimension D is a measure that indicates the amount that a surface fills a space, and can thereby be used to characterize the surface porosity. Here we propose a new method for determining D, based on measuring both the water vapour adsorption isotherm of a given substance, and its ability to act as a cloud condensation nucleus when introduced to humidified air in aerosol form. We show that our method agrees well with previous methods based on measurement of nitrogen adsorption. Besides proving the usefulness of the new method for general surface characterization of materials, our results show that the surface fractal dimension is an important determinant in cloud drop formation on water insoluble particles. We suggest that a closure can be obtained between experimental critical supersaturation for cloud drop activation and that calculated based on water adsorption data, if the latter is corrected using the surface fractal dimension of the insoluble cloud nucleus.

  5. Use of petroleum-based correlations and estimation methods for synthetic fuels

    NASA Technical Reports Server (NTRS)

    Antoine, A. C.

    1980-01-01

    Correlations of hydrogen content with aromatics content, heat of combustion, and smoke point are derived for some synthetic fuels prepared from oil and coal syncrudes. Comparing the results of the aromatics content with correlations derived for petroleum fuels shows that the shale-derived fuels fit the petroleum-based correlations, but the coal-derived fuels do not. The correlations derived for heat of combustion and smoke point are comparable to some found for petroleum-based correlations. Calculated values of hydrogen content and of heat of combustion are obtained for the synthetic fuels by use of ASTM estimation methods. Comparisons of the measured and calculated values show biases in the equations that exceed the critical statistics values. Comparison of the measured hydrogen content by the standard ASTM combustion method with that by a nuclear magnetic resonance (NMR) method shows a decided bias. The comparison of the calculated and measured NMR hydrogen contents shows a difference similar to that found with petroleum fuels.

  6. Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea Test Experiments

    DTIC Science & Technology

    2017-01-19

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/7160--17-9702 Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea ...LIMITATION OF ABSTRACT Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea Test Experiments Roger C. Gauss1 and Joseph M...significantly- updated results from 55 broadband SUS SSS measurements in 6 Critical Sea Test (CST) experiments. Since the time of the previously

  7. Critical viewpoints on the methods of realizing the metal freezing points of the ITS-90

    NASA Astrophysics Data System (ADS)

    Ma, C. K.

    1995-08-01

    The time-honored method for realizing the freezing point tf of a metal (in practice necessarily a dilute alloy) is that of continuous, slow freezing where the plateau temperature (which is the result of solidifying material's being so pure that its phase-transition temperature is observably constant) is measured. The freezing point being an equilibrium temperature, Ancsin considers this method to be inappropriate in principle: equilibrium between the solid and liquid phases cannot be achieved while the solid is being cooled to dispose of the releasing latent heat and while it is accreting at the expense of the liquid. In place of the continuous freezing method he has employed the pulse-heating method (in which the sample is allowed to approach equilibrium after each heat pulse) in his study of Ag; his measurements suggest that freezing can produce non-negligible errors. Here we examine both methods and conclude that the freezing method, employing an inside solid-liquid interface thermally isolated by an outside interface, can provide realizations of the highest accuracy; in either method, perturbation, by inducing solid-liquid phase transition continuously or intermittently, is essential for detecting equilibrium thermally. The respective merits and disadvantages of these two methods and also of the inner-melt method are discussed. We conclude that in a freezing-point measurement what is being measured is in effect the however minutely varying phase transition, and nonconstitutional equilibrium, temperature ti at the solid-liquid interface. The objective is then to measure the ti that is the best measure of tf, which is, normally, the plateau temperature.

  8. An experimental study of the thermodynamic properties of 1,1-difluoroethane

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tamatsu, T.; Sato, T.; Sato, H.

    1992-01-01

    Experimental vapor pressures and P-[rho]-T data of an important alternative refrigerant, 1,1-difluoroethane (HFC-152a), have been measured by means of a constant-volume method coupled with expansion procedures. Sixty P-[rho]-T data were measured along eight isochores in a range of temperatures T from 330 to 440 K, at pressures P from 1.6 to 9.3 MPa, and at densities [rho] from 51 to 811 kg [times] m[sup [minus]3]. Forty-six vapor pressures were also measured at temperatures from 320K to the critical temperature. The uncertainties of the temperature and pressure measurements are within [plus minus]7 mK and [plus minus]2kPa, respectively, while the uncertainties ofmore » the density values is within [plus minus]1%. The purity of the sample used is 99.9 wt%. On the basis of the measurements along each isochore, five saturation points were determined and the critical pressure was determined by correlating the vapor-pressure measurements. The second and third viral coefficients for temperatures from 360 to 440 K have also been determined. 21 refs., 9 figs., 5 tabs.« less

  9. Clean focus, dose and CD metrology for CD uniformity improvement

    NASA Astrophysics Data System (ADS)

    Lee, Honggoo; Han, Sangjun; Hong, Minhyung; Kim, Seungyoung; Lee, Jieun; Lee, DongYoung; Oh, Eungryong; Choi, Ahlin; Kim, Nakyoon; Robinson, John C.; Mengel, Markus; Pablo, Rovira; Yoo, Sungchul; Getin, Raphael; Choi, Dongsub; Jeon, Sanghuck

    2018-03-01

    Lithography process control solutions require more exacting capabilities as the semiconductor industry goes forward to the 1x nm node DRAM device manufacturing. In order to continue scaling down the device feature sizes, critical dimension (CD) uniformity requires continuous improvement to meet the required CD error budget. In this study we investigate using optical measurement technology to improve over CD-SEM methods in focus, dose, and CD. One of the key challenges is measuring scanner focus of device patterns. There are focus measurement methods based on specially designed marks on scribe-line, however, one issue of this approach is that it will report focus of scribe line which is potentially different from that of the real device pattern. In addition, scribe-line marks require additional design and troubleshooting steps that add complexity. In this study, we investigated focus measurement directly on the device pattern. Dose control is typically based on using the linear correlation behavior between dose and CD. The noise of CD measurement, based on CD-SEM for example, will not only impact the accuracy, but also will make it difficult to monitor dose signature on product wafers. In this study we will report the direct dose metrology result using an optical metrology system which especially enhances the DUV spectral coverage to improve the signal to noise ratio. CD-SEM is often used to measure CD after the lithography step. This measurement approach has the advantage of easy recipe setup as well as the flexibility to measure critical feature dimensions, however, we observe that CD-SEM metrology has limitations. In this study, we demonstrate within-field CD uniformity improvement through the extraction of clean scanner slit and scan CD behavior by using optical metrology.

  10. Identification of Lightning Gaps in Mangrove Forests Using Airborne LIDAR Measurements

    NASA Astrophysics Data System (ADS)

    Zhang, K.

    2006-12-01

    Mangrove forests are highly dynamic ecosystems and change frequently due to tropical storms, frost, and lightning. These factors can cause gaps in mangrove forests by damaging trees. Compared to gaps generated by storms and frost, gaps caused by lightning strikes are small, ranging from 50 to 300 m2. However, these small gaps may play a critical role in mangrove forest dynamics because of the frequent occurrence of lightning in tropical areas. It has been hypothesized that the turnover of mangrove forests is mainly due to the death and regeneration of trees in lightning gaps. However, there is a lack of data for gap occurrence in mangrove forests to verify this hypothesis. It is impractical to measure gaps through a field survey on a large scale because of the logistic difficulties of muddy mangrove forests. Airborne light detection and ranging (LIDAR) technology is an effective alternative because it provides direct measurements of ground and canopy elevations remotely. This study developed a method to identify lightning gaps in mangrove forests in terms of LIDAR measurements. First, LIDAR points are classified into vegetation and ground measurements using the progressive morphological filter. Second, a digital canopy model (DCM) is generated by subtracting a digital terrain model (DTM) from a digital surface model (DSM). The DSM is generated by interpolating raw LIDAR measurements, and DTM is produced by interpolating ground measurements. Third, a black top-hat mathematical morphological transformation is used to identify canopy gaps. Comparison of identified gap polygons with raw LIDAR measurements and field surveys shows that the proposed method identifies lightning gaps in mangrove forests successfully. The area of lightning gaps in mangrove forests in Everglades National Park is about 3% of total forest area, which verifies that lightning gaps play a critical role in mangrove forest turnover.

  11. Measurement of cardiac output in children by pressure-recording analytical method.

    PubMed

    Urbano, Javier; López, Jorge; González, Rafael; Solana, María José; Fernández, Sarah N; Bellón, José M; López-Herce, Jesús

    2015-02-01

    We evaluated two pressure-recording analytical method (PRAM) software versions (v.1 and v.2) to measure cardiac index (CI) in hemodynamically stable critically ill children and investigate factors that influence PRAM values. The working hypothesis was that PRAM CI measurements would stay within normal limits in hemodynamically stable patients. Ninety-five CI PRAM measurements were analyzed in 47 patients aged 1-168 months. Mean CI was 4.1 ± 1.4 L/min/m(2) (range 2.0-7.0). CI was outside limits defined as normal (3-5 L/min/m(2)) in 53.7% of measurements (47.8% with software v.1 and 69.2% with software v.2, p = 0.062). Moreover, 14.7% of measurements were below 2.5 L/min/m(2), and 13.6% were above 6 L/min/m(2). CI was significantly lower in patients with a clearly visible dicrotic notch than in those without (3.7 vs. 4.6 L/min/m(2), p = 0.004) and in children with a radial arterial catheter (3.5 L/min/m(2)) than in those with a brachial (4.4 L/min/m(2), p = 0.021) or femoral catheter (4.7 L/min/m(2), p = 0.005). By contrast, CI was significantly higher in children under 12 months (4.2 vs. 3.6 L/min/m(2), p = 0.034) and weighing under 10 kg (4.2 vs. 3.6 L/min/m(2), p = 0.026). No significant differences were observed between cardiac surgery patients and the rest of children. A high percentage of CI measurements registered by PRAM were outside normal limits in hemodynamically stable, critically ill children. CI measured by PRAM may be influenced by the age, weight, location of catheter, and presence of a dicrotic notch.

  12. A model for critical thinking measurement of dental student performance.

    PubMed

    Johnsen, David C; Finkelstein, Michael W; Marshall, Teresa A; Chalkley, Yvonne M

    2009-02-01

    The educational application of critical thinking has increased in the last twenty years with programs like problem-based learning. Performance measurement related to the dental student's capacity for critical thinking remains elusive, however. This article offers a model now in use to measure critical thinking applied to patient assessment and treatment planning across the four years of the dental school curriculum and across clinical disciplines. Two elements of the model are described: 1) a critical thinking measurement "cell," and 2) a list of minimally essential steps in critical thinking for patient assessment and treatment planning. Issues pertaining to this model are discussed: adaptations on the path from novice to expert, the role of subjective measurement, variations supportive of the model, and the correlation of individual and institutional assessment. The critical thinking measurement cell consists of interacting performance tasks and measures. The student identifies the step in the process (for example, chief complaint) with objective measurement; the student then applies the step to a patient or case with subjective measurement; the faculty member then combines the objective and subjective measurements into an evaluation on progress toward competence. The activities in the cell are then repeated until all the steps in the process have been addressed. A next task is to determine consistency across the four years and across clinical disciplines.

  13. Two ways to model voltage current curves of adiabatic MgB2 wires

    NASA Astrophysics Data System (ADS)

    Stenvall, A.; Korpela, A.; Lehtonen, J.; Mikkonen, R.

    2007-08-01

    Usually overheating of the sample destroys attempts to measure voltage-current curves of conduction cooled high critical current MgB2 wires at low temperatures. Typically, when a quench occurs a wire burns out due to massive heat generation and negligible cooling. It has also been suggested that high n values measured with MgB2 wires and coils are not an intrinsic property of the material but arise due to heating during the voltage-current measurement. In addition, quite recently low n values for MgB2 wires have been reported. In order to find out the real properties of MgB2 an efficient computational model is required to simulate the voltage-current measurement. In this paper we go back to basics and consider two models to couple electromagnetic and thermal phenomena. In the first model the magnetization losses are computed according to the critical state model and the flux creep losses are considered separately. In the second model the superconductor resistivity is described by the widely used power law. Then the coupled current diffusion and heat conduction equations are solved with the finite element method. In order to compare the models, example runs are carried out with an adiabatic slab. Both models produce a similar significant temperature rise near the critical current which leads to fictitiously high n values.

  14. Pyrene absorption can be a convenient method for probing critical micellar concentration (cmc) and indexing micellar polarity.

    PubMed

    Basu Ray, Gargi; Chakraborty, Indranil; Moulik, Satya P

    2006-02-01

    The critical micellar concentration (cmc) of both ionic and non-ionic surfactants can be conveniently determined from the measurements of UV absorption of pyrene in surfactant solution. The results on a number of surfactants have agreed with that realized from pyrene fluorescence measurements as well as that obtained following conductometric, tensiometric and calorimetric methods. The absorbance vs [surfactant] profiles for all the major UV spectral peaks of pyrene have been found to be sigmoidal in nature which were analyzed according to Sigmoidal-Boltzmann equation (SBE) to evaluate the cmcs of the studied surfactants. The difference between the initial and the final asymptotes (a(i) and a(f), respectively) of the sigmoidal profile, Delta a = (a(f)-a(i)) and the slope of the sigmoid, S(sig) have been observed to depend on the type of the surfactant. The Delta a has shown a linear correlation with the ratio of the fluorescence intensities of the first and the third vibronic peaks, I1/I3 of pyrene which is considered as a measure of the environmental polarity (herein micellar interior) of the probe (pyrene). Thus, Delta a values have the prospect for use as another index for the estimation of polarity of micellar interior.

  15. Advanced overlay analysis through design based metrology

    NASA Astrophysics Data System (ADS)

    Ji, Sunkeun; Yoo, Gyun; Jo, Gyoyeon; Kang, Hyunwoo; Park, Minwoo; Kim, Jungchan; Park, Chanha; Yang, Hyunjo; Yim, Donggyu; Maruyama, Kotaro; Park, Byungjun; Yamamoto, Masahiro

    2015-03-01

    As design rule shrink, overlay has been critical factor for semiconductor manufacturing. However, the overlay error which is determined by a conventional measurement with an overlay mark based on IBO and DBO often does not represent the physical placement error in the cell area. The mismatch may arise from the size or pitch difference between the overlay mark and the cell pattern. Pattern distortion caused by etching or CMP also can be a source of the mismatch. In 2014, we have demonstrated that method of overlay measurement in the cell area by using DBM (Design Based Metrology) tool has more accurate overlay value than conventional method by using an overlay mark. We have verified the reproducibility by measuring repeatable patterns in the cell area, and also demonstrated the reliability by comparing with CD-SEM data. We have focused overlay mismatching between overlay mark and cell area until now, further more we have concerned with the cell area having different pattern density and etch loading. There appears a phenomenon which has different overlay values on the cells with diverse patterning environment. In this paper, the overlay error was investigated from cell edge to center. For this experiment, we have verified several critical layers in DRAM by using improved(Better resolution and speed) DBM tool, NGR3520.

  16. Using wavelength-normalized optical spectroscopy to improve the accuracy of bacteria growth rate quantification

    NASA Astrophysics Data System (ADS)

    McBirney, Samantha E.; Trinh, Kristy; Wong-Beringer, Annie; Armani, Andrea M.

    2017-02-01

    One of the fundamental analytical measurements performed in microbiology is monitoring and characterizing cell concentration in culture media. Measurement error will give rise to reproducibility problems in a wide range of applications, from biomanufacturing to basic research. Therefore, it is critical that the generated results are consistent. Single wavelength optical density (OD) measurements have become the preferred approach. Here, we compare the conventional OD600 technique with a multi-wavelength normalized scattering optical spectroscopy method to measure the growth rates of Pseudomonas aeruginosa and Staphylococcus aureus, two of the leading nosocomial pathogens with proven abilities to develop resistance. The multi-wavelength normalization process minimizes the impact of bacteria byproducts and environmental noise on the signal, thereby accurately quantifying growth rates with high fidelity at low concentrations. In contrast, due to poor absorbance and scattering at 600 nm, the classic OD600 measurement method is able to detect bacteria but cannot quantify the growth rate reliably. Our wavelength-normalization protocol to detect bacteria growth rates can be readily and easily adopted by research labs, given that it only requires the use of a standard spectrophotometer and implementation of straightforward data analysis. Measuring and monitoring bacteria growth rates play a critical role in a wide range of settings, spanning from therapeutic design and development to diagnostics and disease prevention. Having a full understanding of the growth cycles of bacteria known to cause severe infections and diseases will lead to a better understanding of the pathogenesis of these illnesses, leading to better treatment and, ultimately, the development of a cure.

  17. Compression and Transmission of RF Signals for Telediagnosis

    NASA Astrophysics Data System (ADS)

    Seko, Toshihiro; Doi, Motonori; Oshiro, Osamu; Chihara, Kunihiro

    2000-05-01

    Health care is a critical issue nowadays. Much emphasis is given to quality care for all people. Telediagnosis has attracted public attention. We propose a new method of ultrasound image transmission for telediagnosis. In conventional methods, video image signals are transmitted. In our method, the RF signals which are acquired by an ultrasound probe, are transmitted. The RF signals can be transformed to color Doppler images or high-resolution images by a receiver. Because a stored form is adopted, the proposed system can be realized with existent technology such as hyper text transfer protocol (HTTP) and file transfer protocol (FTP). In this paper, we describe two lossless compression methods which specialize in the transmission of RF signals. One of the methods uses the characteristics of the RF signal. In the other method, the amount of the data is reduced. Measurements were performed in water targeting an iron block and triangular Styrofoam. Additionally, abdominal fat measurement was performed. Our method achieved a compression rate of 13% with 8 bit data.

  18. A Model of Risk Analysis in Analytical Methodology for Biopharmaceutical Quality Control.

    PubMed

    Andrade, Cleyton Lage; Herrera, Miguel Angel De La O; Lemes, Elezer Monte Blanco

    2018-01-01

    One key quality control parameter for biopharmaceutical products is the analysis of residual cellular DNA. To determine small amounts of DNA (around 100 pg) that may be in a biologically derived drug substance, an analytical method should be sensitive, robust, reliable, and accurate. In principle, three techniques have the ability to measure residual cellular DNA: radioactive dot-blot, a type of hybridization; threshold analysis; and quantitative polymerase chain reaction. Quality risk management is a systematic process for evaluating, controlling, and reporting of risks that may affects method capabilities and supports a scientific and practical approach to decision making. This paper evaluates, by quality risk management, an alternative approach to assessing the performance risks associated with quality control methods used with biopharmaceuticals, using the tool hazard analysis and critical control points. This tool provides the possibility to find the steps in an analytical procedure with higher impact on method performance. By applying these principles to DNA analysis methods, we conclude that the radioactive dot-blot assay has the largest number of critical control points, followed by quantitative polymerase chain reaction, and threshold analysis. From the analysis of hazards (i.e., points of method failure) and the associated method procedure critical control points, we conclude that the analytical methodology with the lowest risk for performance failure for residual cellular DNA testing is quantitative polymerase chain reaction. LAY ABSTRACT: In order to mitigate the risk of adverse events by residual cellular DNA that is not completely cleared from downstream production processes, regulatory agencies have required the industry to guarantee a very low level of DNA in biologically derived pharmaceutical products. The technique historically used was radioactive blot hybridization. However, the technique is a challenging method to implement in a quality control laboratory: It is laborious, time consuming, semi-quantitative, and requires a radioisotope. Along with dot-blot hybridization, two alternatives techniques were evaluated: threshold analysis and quantitative polymerase chain reaction. Quality risk management tools were applied to compare the techniques, taking into account the uncertainties, the possibility of circumstances or future events, and their effects upon method performance. By illustrating the application of these tools with DNA methods, we provide an example of how they can be used to support a scientific and practical approach to decision making and can assess and manage method performance risk using such tools. This paper discusses, considering the principles of quality risk management, an additional approach to the development and selection of analytical quality control methods using the risk analysis tool hazard analysis and critical control points. This tool provides the possibility to find the method procedural steps with higher impact on method reliability (called critical control points). Our model concluded that the radioactive dot-blot assay has the larger number of critical control points, followed by quantitative polymerase chain reaction and threshold analysis. Quantitative polymerase chain reaction is shown to be the better alternative analytical methodology in residual cellular DNA analysis. © PDA, Inc. 2018.

  19. Total plasma magnesium in healthy and critically ill foals.

    PubMed

    Mariella, J; Isani, G; Andreani, G; Freccero, F; Carpenè, E; Castagnetti, C

    2016-01-15

    Abnormalities in total Mg (tMg) concentration in plasma and/or serum are common in critically ill humans, and the association with increased mortality has been documented in several clinical studies in adults and newborns with hypoxic-ischemic encephalopathy. Abnormalities in tMg were studied in hospitalized dogs, cats, and adult horses. Newborn foals were scarcely studied with regard to Mg concentration. The aims of the present study were: (1) to compare two analytical methods for the determination of tMg in plasma: the automated colorimetric method and the atomic absorption spectrometry; (2) to measure plasma tMg in healthy foals during the first 72 hours after birth and in sick foals during the first 72 hours of hospitalization; (3) to compare total plasma Mg concentration among healthy foals, foals affected by perinatal asphyxia syndrome (PAS), prematurity and/or dismaturity, and sepsis; (4) to evaluate tMg plasma concentration in surviving and non-surviving foals. One hundred seventeen foals were included in the study: 20 healthy and 97 sick foals. The automated method used in clinical practice probably overestimates plasma tMg. Due to its higher sensitivity and specificity, the atomic absorption spectrometry should be considered the method of choice from an analytical point of view, but requires an instrumentation not easily available in any laboratory and specific technical skills and competencies. Plasma tMg in healthy foals were included in the range 0.52 to 1.01 mmol/L and did not show any time-dependent change during the first 72 hours of life. In sick foals, tMg evaluated at T0 was statistically higher than tMg measured at subsequent times. Foals affected by PAS had a tMg at T0 significantly higher (P < 0.01) than healthy, septic, and premature and/or dysmature foals. The t test found significantly higher (P < 0.01) plasma tMg measured at T0 in non-surviving than in surviving foals. Plasma tMg could be a useful parameter for the diagnosis of PAS and the formulation of the prognosis in critically ill foals. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Novel method for measurement of transistor gate length using energy-filtered transmission electron microscopy

    NASA Astrophysics Data System (ADS)

    Lee, Sungho; Kim, Tae-Hoon; Kang, Jonghyuk; Yang, Cheol-Woong

    2016-12-01

    As the feature size of devices continues to decrease, transmission electron microscopy (TEM) is becoming indispensable for measuring the critical dimension (CD) of structures. Semiconductors consist primarily of silicon-based materials such as silicon, silicon dioxide, and silicon nitride, and the electrons transmitted through a plan-view TEM sample provide diverse information about various overlapped silicon-based materials. This information is exceedingly complex, which makes it difficult to clarify the boundary to be measured. Therefore, we propose a simple measurement method using energy-filtered TEM (EF-TEM). A precise and effective measurement condition was obtained by determining the maximum value of the integrated area ratio of the electron energy loss spectrum at the boundary to be measured. This method employs an adjustable slit allowing only electrons with a certain energy range to pass. EF-TEM imaging showed a sharp transition at the boundary when the energy-filter’s passband centre was set at 90 eV, with a slit width of 40 eV. This was the optimum condition for the CD measurement of silicon-based materials involving silicon nitride. Electron energy loss spectroscopy (EELS) and EF-TEM images were used to verify this method, which makes it possible to measure the transistor gate length in a dynamic random access memory manufactured using 35 nm process technology. This method can be adapted to measure the CD of other non-silicon-based materials using the EELS area ratio of the boundary materials.

  1. Universality of magnetic-field-induced Bose-Einstein condensation of magnons

    NASA Astrophysics Data System (ADS)

    Shirasawa, Kazuki; Kurita, Nobuyuki; Tanaka, Hidekazu

    2017-10-01

    CsFeBr3 is an S =1 hexagonal antiferromagnet that has a singlet ground state owing to its large easy-plane single-ion anisotropy. The critical behavior of the magnetic-field-induced phase transition for a magnetic field parallel to the c axis, which can be described by the Bose-Einstein condensation (BEC) of magnons under the U (1 ) symmetry, was investigated via magnetization and specific heat measurements down to 0.1 K. For the specific heat measurement, we have developed a method of effectively suppressing the torque acting on a sample with strong anisotropy that uses the spin dimer compound Ba2CoSi2O6Cl2 with large and anisotropic Van Vleck paramagnetism. The temperature dependence of the transition field Hc(T ) was found to follow the power-law Hc(T ) -Hc∝Tϕ with a critical exponent of ϕ =1.50 ±0.02 and critical field of Hc=2.60 T . This result verifies the universality of the three-dimensional BEC of magnons described by ϕBEC=3 /2 .

  2. Hypoglycemia in Critically Ill Children

    PubMed Central

    Faustino, E Vincent S; Hirshberg, Eliotte L; Bogue, Clifford W

    2012-01-01

    Background The practice of glycemic control with intravenous insulin in critically ill patients has brought clinical focus on understanding the effects of hypoglycemia, especially in children. Very little is published on the impact of hypoglycemia in this population. We aimed to review the existing literature on hypoglycemia in critically ill neonates and children. Methods We performed a systematic review of the literature up to August 2011 using PubMed, Ovid MEDLINE and ISI Web of Science using the search terms “hypoglycemia or hypoglyc*” and “critical care or intensive care or critical illness”. Articles were limited to “all child (0–18 years old)” and “English”. Results A total of 513 articles were identified and 132 were included for review. Hypoglycemia is a significant concern among pediatric and neonatal intensivists. Its definition is complicated by the use of a biochemical measure (i.e., blood glucose) for a pathophysiologic problem (i.e., neuroglycopenia). Based on associated outcomes, we suggest defining hypoglycemia as <40–45 mg/dl in neonates and <60–65 mg/dl in children. Below the suggested threshold values, hypoglycemia is associated with worse neurological outcomes, increased intensive care unit stay, and increased mortality. Disruptions in carbohydrate metabolism increase the risk of hypoglycemia incritically ill children. Prevention of hypoglycemia, especially in the setting of intravenous insulin use, will be best accomplished by the combination of accurate measuring techniques, frequent or continuous glucose monitoring, and computerized insulin titration protocols. Conclusion Studies on hypoglycemia in critically ill children have focused on spontaneous hypoglycemia. With the current practice of maintaining blood glucose within a narrow range with intravenous insulin, the risk factors and outcomes associated with insulin-induced hypoglycemia should be rigorously studied to prevent hypoglycemia and potentially improve outcomes of critically ill children. PMID:22401322

  3. Impact of interdisciplinary learning on critical thinking using case study method in allied health care graduate students.

    PubMed

    Zimmerman, Scott D; Lester Short, Glenda F; Hendrix, E Michael

    2011-01-01

    It remains unclear which classroom experiences, if any, foster critical think ability. We measured the effectiveness of interdisciplinary, case-based learning on the critical-thinking ability of graduate students enrolled in allied health care programs. We designed a voluntary classroom experience to examine the effectiveness of case studies used in an interdisciplinary setting to increase critical-thinking ability. Two groups of students were measured for their critical thinking ability using an online assessment both before and after their respective classroom experiences. One group of 14 graduate students from 4 different allied health care programs (interdisciplinary, ID) discussed complex interdisciplinary case studies and answered multiple-choice type questions formed around the cases. The second group was composed of graduate students (n = 28) from a single disciple enrolled in a clinical anatomy course (discipline specific, DS). They discussed complex case studies specific to their discipline and answered multiple-choice questions formed around the cases. There was no overall change in critical-thinking scores from the pre- to post-test in either group (delta scores: ID 1.5 ± 5.3, DS -1.7 ± 5.7). However, ID students scoring below the median on the pretest improved significantly (paired t-test, pre 50.7 ± 3.8, post 54.2 ± 1.7, p = 0.02). The interdisciplinary learning experience improved critical-thinking ability in students with the least proficiency. As case studies have long been used to advance deeper learning, these data provide evidence for a broader impact of cases when used in an interdisciplinary setting, especially for those students coming in with the least ability.

  4. Scale-4 Analysis of Pressurized Water Reactor Critical Configurations: Volume 2-Sequoyah Unit 2 Cycle 3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, S.M.

    1995-01-01

    The requirements of ANSI/ANS 8.1 specify that calculational methods for away-from-reactor criticality safety analyses be validated against experimental measurements. If credit for the negative reactivity of the depleted (or spent) fuel isotopics is desired, it is necessary to benchmark computational methods against spent fuel critical configurations. This report summarizes a portion of the ongoing effort to benchmark away-from-reactor criticality analysis methods using critical configurations from commercial pressurized-water reactors. The analysis methodology selected for all the calculations reported herein is based on the codes and data provided in the SCALE-4 code system. The isotopic densities for the spent fuel assemblies inmore » the critical configurations were calculated using the SAS2H analytical sequence of the SCALE-4 system. The sources of data and the procedures for deriving SAS2H input parameters are described in detail. The SNIKR code module was used to extract the necessary isotopic densities from the SAS2H results and provide the data in the format required by the SCALE criticality analysis modules. The CSASN analytical sequence in SCALE-4 was used to perform resonance processing of the cross sections. The KENO V.a module of SCALE-4 was used to calculate the effective multiplication factor (k{sub eff}) of each case. The SCALE-4 27-group burnup library containing ENDF/B-IV (actinides) and ENDF/B-V (fission products) data was used for all the calculations. This volume of the report documents the SCALE system analysis of three reactor critical configurations for the Sequoyah Unit 2 Cycle 3. This unit and cycle were chosen because of the relevance in spent fuel benchmark applications: (1) the unit had a significantly long downtime of 2.7 years during the middle of cycle (MOC) 3, and (2) the core consisted entirely of burned fuel at the MOC restart. The first benchmark critical calculation was the MOC restart at hot, full-power (HFP) critical conditions. The other two benchmark critical calculations were the beginning-of-cycle (BOC) startup at both hot, zero-power (HZP) and HFP critical conditions. These latter calculations were used to check for consistency in the calculated results for different burnups and downtimes. The k{sub eff} results were in the range of 1.00014 to 1.00259 with a standard deviation of less than 0.001.« less

  5. A comparison of sleep assessment tools by nurses and patients in critical care.

    PubMed

    Richardson, Annette; Crow, Wendy; Coghill, Elaine; Turnock, Christopher

    2007-09-01

    The aim of this critical care sleep assessment pilot study was to evaluate the usefulness of three sleep assessment tools to identify which, if any, provided the closest comparison between the nurses' judgement and the patients' experience of their sleep. The study objectives were to: (i) compare patients' and nurses' assessment of sleep using three different rating tools. (ii) Ascertain patients' preferences with non-interventional, user friendly, practical tools in critical care. (iii) Recommend changes and improvements to the way that sleep is assessed and documented. Sleep is important for promoting critical care recovery and sleep disturbance is known to cause irritability, aggression and increased stress levels. The availability and use of valid critical care sleep assessment tools is limited. A descriptive comparative study using three sleep assessment-rating scales were constructed to provide easy to understand tools for completion by both patients and nurses in critical care. Structured interviews were undertaken with 82 patients and 82 nurses using a convenience sample from four multispecialty critical care units in one large teaching trust. Patients were included in the study if they met a list of pre-defined criteria to obtain responses from lucid orientated patients. No tool produced a close association between the nurses' assessment of the patients sleep and the patients' assessment of their sleep. Patients found two of the three tools easy to use when rating their sleep. Discussion. Objective invasive measurements of sleep as well as complex subjective tools appear inappropriate to be used as a part of daily critical care practice. The application of simple rating scores has a high degree of error when nurses assess patients' sleep, even though high levels of patient observation and assessment are practiced in critical care. More research is needed to examine the assessment of sleep in critical care, particularly linking rating scales to alternative methods of physiological assessment of sleep. Findings indicate nurses are unable to accurately assess critical care patients' sleep using rating assessment tools. However patients were found to prefer two sleep assessment tools, one banded in hours to assess sleep quantity and one as a comparison against normal sleep to assess sleep quality. This study reviews the importance of sleep assessment and the diverse methods available for assessing sleep focussing on the critically ill patient. More noteworthy it highlights how nurses sole judgements of patients sleep is not a reliable method in clinical practice, however it provides some indication on the application of 'easy to use' tools to assist in the patients assessments of their sleep.

  6. Evaluating the quality of a cell counting measurement process via a dilution series experimental design.

    PubMed

    Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng

    2017-12-01

    Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.

  7. BridgeRank: A novel fast centrality measure based on local structure of the network

    NASA Astrophysics Data System (ADS)

    Salavati, Chiman; Abdollahpouri, Alireza; Manbari, Zhaleh

    2018-04-01

    Ranking nodes in complex networks have become an important task in many application domains. In a complex network, influential nodes are those that have the most spreading ability. Thus, identifying influential nodes based on their spreading ability is a fundamental task in different applications such as viral marketing. One of the most important centrality measures to ranking nodes is closeness centrality which is efficient but suffers from high computational complexity O(n3) . This paper tries to improve closeness centrality by utilizing the local structure of nodes and presents a new ranking algorithm, called BridgeRank centrality. The proposed method computes local centrality value for each node. For this purpose, at first, communities are detected and the relationship between communities is completely ignored. Then, by applying a centrality in each community, only one best critical node from each community is extracted. Finally, the nodes are ranked based on computing the sum of the shortest path length of nodes to obtained critical nodes. We have also modified the proposed method by weighting the original BridgeRank and selecting several nodes from each community based on the density of that community. Our method can find the best nodes with high spread ability and low time complexity, which make it applicable to large-scale networks. To evaluate the performance of the proposed method, we use the SIR diffusion model. Finally, experiments on real and artificial networks show that our method is able to identify influential nodes so efficiently, and achieves better performance compared to other recent methods.

  8. Important considerations in lesion-symptom mapping: Illustrations from studies of word comprehension.

    PubMed

    Shahid, Hinna; Sebastian, Rajani; Schnur, Tatiana T; Hanayik, Taylor; Wright, Amy; Tippett, Donna C; Fridriksson, Julius; Rorden, Chris; Hillis, Argye E

    2017-06-01

    Lesion-symptom mapping is an important method of identifying networks of brain regions critical for functions. However, results might be influenced substantially by the imaging modality and timing of assessment. We tested the hypothesis that brain regions found to be associated with acute language deficits depend on (1) timing of behavioral measurement, (2) imaging sequences utilized to define the "lesion" (structural abnormality only or structural plus perfusion abnormality), and (3) power of the study. We studied 191 individuals with acute left hemisphere stroke with MRI and language testing to identify areas critical for spoken word comprehension. We use the data from this study to examine the potential impact of these three variables on lesion-symptom mapping. We found that only the combination of structural and perfusion imaging within 48 h of onset identified areas where more abnormal voxels was associated with more severe acute deficits, after controlling for lesion volume and multiple comparisons. The critical area identified with this methodology was the left posterior superior temporal gyrus, consistent with other methods that have identified an important role of this area in spoken word comprehension. Results have implications for interpretation of other lesion-symptom mapping studies, as well as for understanding areas critical for auditory word comprehension in the healthy brain. We propose that lesion-symptom mapping at the acute stage of stroke addresses a different sort of question about brain-behavior relationships than lesion-symptom mapping at the chronic stage, but that timing of behavioral measurement and imaging modalities should be considered in either case. Hum Brain Mapp 38:2990-3000, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  9. Healthy-years equivalent: wounded but not yet dead.

    PubMed

    Hauber, A Brett

    2009-06-01

    The quality-adjusted life-year (QALY) has become the dominant measure of health value in health technology assessment in recent decades despite some well-known and fundamental flaws in the preference-elicitation methods used to construct health-state utility weights and the strong assumptions required to construct QALYs as a measure of health value using these utility weights. The healthy-years equivalent (HYE) was proposed as an alternative measure of health value that was purported to overcome many of the limitations of the QALY. The primary argument against the HYE is that it is difficult to estimate and, therefore, impractical. After much debate in the literature, the QALY appears to have won the battle; however, the HYE is not yet dead. Empirical research and recent advances in methods continue to offer evidence of the feasibility using the HYE as a measure of health value and also addresses some of criticisms surrounding the preference-elicitation methods used to estimate the HYE. This article provides a brief review of empirical applications of the HYE and identifies recent advances in empirical estimation that may breathe new life into a valiant, but wounded, measure.

  10. A method for rapid quantitative assessment of biofilms with biomolecular staining and image analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larimer, Curtis J.; Winder, Eric M.; Jeters, Robert T.

    Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results weremore » compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.« less

  11. A method for rapid quantitative assessment of biofilms with biomolecular staining and image analysis

    DOE PAGES

    Larimer, Curtis J.; Winder, Eric M.; Jeters, Robert T.; ...

    2015-12-07

    Here, the accumulation of bacteria in surface attached biofilms, or biofouling, can be detrimental to human health, dental hygiene, and many industrial processes. A critical need in identifying and preventing the deleterious effects of biofilms is the ability to observe and quantify their development. Analytical methods capable of assessing early stage fouling are cumbersome or lab-confined, subjective, and qualitative. Herein, a novel photographic method is described that uses biomolecular staining and image analysis to enhance contrast of early stage biofouling. A robust algorithm was developed to objectively and quantitatively measure surface accumulation of Pseudomonas putida from photographs and results weremore » compared to independent measurements of cell density. Results from image analysis quantified biofilm growth intensity accurately and with approximately the same precision of the more laborious cell counting method. This simple method for early stage biofilm detection enables quantifiable measurement of surface fouling and is flexible enough to be applied from the laboratory to the field. Broad spectrum staining highlights fouling biomass, photography quickly captures a large area of interest, and image analysis rapidly quantifies fouling in the image.« less

  12. Traceability in hardness measurements: from the definition to industry

    NASA Astrophysics Data System (ADS)

    Germak, Alessandro; Herrmann, Konrad; Low, Samuel

    2010-04-01

    The measurement of hardness has been and continues to be of significant importance to many of the world's manufacturing industries. Conventional hardness testing is the most commonly used method for acceptance testing and production quality control of metals and metallic products. Instrumented indentation is one of the few techniques available for obtaining various property values for coatings and electronic products in the micrometre and nanometre dimensional scales. For these industries to be successful, it is critical that measurements made by suppliers and customers agree within some practical limits. To help assure this measurement agreement, a traceability chain for hardness measurement traceability from the hardness definition to industry has developed and evolved over the past 100 years, but its development has been complicated. A hardness measurement value not only requires traceability of force, length and time measurements but also requires traceability of the hardness values measured by the hardness machine. These multiple traceability paths are needed because a hardness measurement is affected by other influence parameters that are often difficult to identify, quantify and correct. This paper describes the current situation of hardness measurement traceability that exists for the conventional hardness methods (i.e. Rockwell, Brinell, Vickers and Knoop hardness) and for special-application hardness and indentation methods (i.e. elastomer, dynamic, portables and instrumented indentation).

  13. Tsunami forecast by joint inversion of real-time tsunami waveforms and seismic of GPS data: application to the Tohoku 2011 tsunami

    USGS Publications Warehouse

    Yong, Wei; Newman, Andrew V.; Hayes, Gavin P.; Titov, Vasily V.; Tang, Liujuan

    2014-01-01

    Correctly characterizing tsunami source generation is the most critical component of modern tsunami forecasting. Although difficult to quantify directly, a tsunami source can be modeled via different methods using a variety of measurements from deep-ocean tsunameters, seismometers, GPS, and other advanced instruments, some of which in or near real time. Here we assess the performance of different source models for the destructive 11 March 2011 Japan tsunami using model–data comparison for the generation, propagation, and inundation in the near field of Japan. This comparative study of tsunami source models addresses the advantages and limitations of different real-time measurements with potential use in early tsunami warning in the near and far field. The study highlights the critical role of deep-ocean tsunami measurements and rapid validation of the approximate tsunami source for high-quality forecasting. We show that these tsunami measurements are compatible with other real-time geodetic data, and may provide more insightful understanding of tsunami generation from earthquakes, as well as from nonseismic processes such as submarine landslide failures.

  14. (abstract) A Comparison Between Measurements of the F-layer Critical Frequency and Values Derived from the PRISM Adjustment Algorithm Applied to Total Electron Content Data in the Equatorial Region

    NASA Technical Reports Server (NTRS)

    Mannucci, A. J.; Anderson, D. N.; Abdu, A. M.

    1994-01-01

    The Parametrized Real-Time Ionosphere Specification Model (PRISM) is a global ionospheric specification model that can incorporate real-time data to compute accurate electron density profiles. Time series of computed and measured data are compared in this paper. This comparison can be used to suggest methods of optimizing the PRISM adjustment algorithm for TEC data obtained at low altitudes.

  15. Measurement of salivary cortisol level for the diagnosis of critical illness-related corticosteroid insufficiency in children.

    PubMed

    Gunnala, Vishal; Guo, Rong; Minutti, Carla; Durazo-Arvizu, Ramon; Laporte, Cynthia; Mathews, Herbert; Kliethermis, Stephanie; Bhatia, Rahul

    2015-05-01

    To compare serum total, serum free and salivary cortisol in critically ill children. Prospective observational cohort study. Tertiary pediatric critical care unit at Ronald McDonald Children's Hospital at Loyola University Medical Center. We enrolled 59 patients (4 weeks to 18 years of age) between January 2012 and May 2013. Thirty-four patients were included in the salivary to serum free cortisol correlational analysis. Blood and saliva samples were obtained simultaneously within 24 hours of admission between the hours of 6 AM and 12 PM. Salivary cortisol was tested by liquid chromatography/tandem mass spectrometry, serum free cortisol by liquid chromatography/tandem mass spectrometry followed by equilibrium dialysis, and serum total cortisol by liquid chromatography/tandem mass spectrometry. Salivary and serum free cortisol values from 34 patients had a correlation coefficient (r) of 0.87 (95% CI, 0.75-0.93; p < 0.0001). The total serum and salivary cortisol values had a correlation coefficient (r) of 0.67 (95% CI, 0.42-0.81; p < 0.0001). The total serum and serum free cortisol values had a correlation coefficient (r) of 0.83 (95% CI, 0.69-0.91; p < 0.0001). Serum free and salivary cortisol values correlate in critically ill children. Salivary cortisol can be used as a surrogate for serum free cortisol in critically ill pediatric patients. Salivary cortisol is a cost-effective and less invasive measure of bioavailable cortisol and offers an alternate and accurate method for assessing critical illness-related corticosteroid insufficiency in children.

  16. The effects of using a human patient simulator compared to a CD-ROM in teaching critical thinking and performance.

    PubMed

    Johnson, Don; Johnson, Sabine

    2014-01-01

    Military healthcare personnel, including nurse anesthetists, must have the knowledge and skills to care for the extensive, severe injuries incurred on the battlefield. No studies have compared the 2 teaching strategies of using the human patient simulator (HPS) and a CD-ROM in caring for combat injuries relative to critical thinking and performance using nurse anesthesia participants. A prospective, pretest-posttest experimental, mixed design (within and between) was used to determine if there were statistically significant differences in HPS and CD-ROM educational strategies relative to caring for patients who have trauma. Two instruments were used: critical thinking, which consisted of multiple-choice questions; and a combat performance instrument that measured ability to care for patients. A repeated analysis of variance and a least significant difference post-hoc test were used to analyze the data. The HPS group performed better than the CD-ROM and control groups relative to performance (P=.000) but not on critical thinking (P=.239). There was no difference between the CD-ROM and control group (P=.171) on the combat performance instrument. In this study, the HPS method of instruction was a more effective method of teaching than the CD-ROM approach.

  17. Ex-situ manufacturing of SiC-doped MgB2 used for superconducting wire in medical device applications

    NASA Astrophysics Data System (ADS)

    Herbirowo, Satrio; Imaduddin, Agung; Sofyan, Nofrijon; Yuwono, Akhmad Herman

    2017-02-01

    Magnesium diboride (MgB2) is a superconductor material with a relatively high critical temperature. Due to its relatively high critical temperature, this material is promising and has the potential to replace Nb3Sn for wire superconducting used in many medical devices. In this work, nanoparticle SiC-doped MgB2 superconducting material has been fabricated through an ex-situ method. The doping of nanoparticle SiC by 10 and 15 wt% was conducted to analyze its effect on specific resistivity of MgB2. The experiment was started by weighing a stoichiometric amount of MgB2 and nanoparticles SiC. Both materials were mixed and grounded for 30 minutes by using an agate mortar. The specimens were then pressed into a 6 mm diameter stainless steel tube, which was then reduced until 3 mm through a wire drawing method. X-ray diffraction analysis was conducted to confirm the phase, whereas the superconductivity of the specimens was analyzed by using resistivity measurement under cryogenic magnetic system. The results indicated that the commercial MgB2 showed a critical temperature of 37.5 K whereas the SiC doped MgB2 has critical temperature of 38.3 K.

  18. Multi-intelligence critical rating assessment of fusion techniques (MiCRAFT)

    NASA Astrophysics Data System (ADS)

    Blasch, Erik

    2015-06-01

    Assessment of multi-intelligence fusion techniques includes credibility of algorithm performance, quality of results against mission needs, and usability in a work-domain context. Situation awareness (SAW) brings together low-level information fusion (tracking and identification), high-level information fusion (threat and scenario-based assessment), and information fusion level 5 user refinement (physical, cognitive, and information tasks). To measure SAW, we discuss the SAGAT (Situational Awareness Global Assessment Technique) technique for a multi-intelligence fusion (MIF) system assessment that focuses on the advantages of MIF against single intelligence sources. Building on the NASA TLX (Task Load Index), SAGAT probes, SART (Situational Awareness Rating Technique) questionnaires, and CDM (Critical Decision Method) decision points; we highlight these tools for use in a Multi-Intelligence Critical Rating Assessment of Fusion Techniques (MiCRAFT). The focus is to measure user refinement of a situation over the information fusion quality of service (QoS) metrics: timeliness, accuracy, confidence, workload (cost), and attention (throughput). A key component of any user analysis includes correlation, association, and summarization of data; so we also seek measures of product quality and QuEST of information. Building a notion of product quality from multi-intelligence tools is typically subjective which needs to be aligned with objective machine metrics.

  19. Energy and Protein in Critically Ill Patients with AKI: A Prospective, Multicenter Observational Study Using Indirect Calorimetry and Protein Catabolic Rate.

    PubMed

    Sabatino, Alice; Theilla, Miriam; Hellerman, Moran; Singer, Pierre; Maggiore, Umberto; Barbagallo, Maria; Regolisti, Giuseppe; Fiaccadori, Enrico

    2017-07-26

    The optimal nutritional support in Acute Kidney Injury (AKI) still remains an open issue. The present study was aimed at evaluating the validity of conventional predictive formulas for the calculation of both energy expenditure and protein needs in critically ill patients with AKI. A prospective, multicenter, observational study was conducted on adult patients hospitalized with AKI in three different intensive care units (ICU). Nutrient needs were estimated by different methods: the Guidelines of the European Society of Parenteral and Enteral Nutrition (ESPEN) for both calories and proteins, the Harris-Benedict equation, the Penn-State and Faisy-Fagon equations for energy. Actual energy and protein needs were repeatedly measured by indirect calorimetry (IC) and protein catabolic rate (PCR) until oral nutrition start, hospital discharge or renal function recovery. Forty-two patients with AKI were enrolled, with 130 IC and 123 PCR measurements obtained over 654 days of artificial nutrition. No predictive formula was precise enough, and Bland-Altman plots wide limits of agreement for all equations highlight the potential to under- or overfeed individual patients. Conventional predictive formulas may frequently lead to incorrect energy and protein need estimation. In critically ill patients with AKI an increased risk for under- or overfeeding is likely when nutrient needs are estimated instead of measured.

  20. Study of SRM Critical Surfaces Using Near Infrared Optical Fiber Spectrometry

    NASA Technical Reports Server (NTRS)

    Workman, G. L.; Hughes, C.; Arendale, W. A.

    1997-01-01

    The measurement and control of cleanliness for critical surfaces during manufacturing and in service operations provides a unique challenge in the current thrust for environmentally benign processes. Of particular interest has been work performed in maintaining quality in the production of bondline surfaces in propulsion systems and the identification of possible contaminants which are detrimental to the integrity of the bondline. This work requires an in-depth study of the possible sources of contamination, methodologies to identify contaminants, discrimination between contaminants and chemical species caused by environment, and the effect of particular contaminants on the bondline integrity of the critical surfaces. This paper will provide an introduction to the use of Near Infrared (NIR) optical fiber spectrometry in a nondestructive measurement system for process monitoring and how it can be used to help clarify issues concerning surface chemistry. In a previous conference, experimental results for quantitative measurement of silicone and Conoco HD2 greases, and tape residues on solid rocket motor surfaces were presented. This paper will present data for metal hydroxides and discuss the use of the integrating sphere to minimize the effects of physical properties of the surfaces (such as surface roughness) on the results obtained from the chemometric methods used for quantitative analysis.

  1. Critical Thinking as a Predictor and Outcome Measure in a Large Undergraduate Educational Psychology Course.

    ERIC Educational Resources Information Center

    Williams, Robert L.

    This study first determined how well two types of critical thinking measures, generic and subject-specific, predicted performance on course tests. Secondly, the study examined the extent to which critical thinking changed from the beginning to the end of the course. Two generic and one subject-specific measure of critical thinking were used in the…

  2. An Evaluation of American Board Teacher Certification: Progress and Plans

    ERIC Educational Resources Information Center

    Glazerman, Steven; Tuttle, Christina

    2006-01-01

    Education policymakers have long sought to establish teaching standards that will measure new or continuing teachers against these standards. The problem is, existing methods for certifying teachers have been criticized for being either so onerous as to deter good candidates or so lax as to keep weak teachers in the profession. To provide another…

  3. The Collegiate Learning Assessment: Setting Standards for Performance at a College or University. Technical Report

    ERIC Educational Resources Information Center

    Hardison, Chaitra M.; Vilamovska, Anna-Marie

    2009-01-01

    The Collegiate Learning Assessment (CLA) is a measure of how much students' critical thinking improves after attending college or university. This report illustrates how institutions can set their own standards on the CLA using a method that is appropriate for the CLA's unique characteristics. The authors examined evidence of reliability and…

  4. The NAEP Guide: A Description of the Content and Methods of the 1997 and 1998 Assessments. Revised Edition.

    ERIC Educational Resources Information Center

    Calderone, John, Ed.; King, Laura Mitchell, Ed.; Horkay, Nancy, Ed.

    The National Assessment of Educational Progress (NAEP), often called the "Nation's Report Card," is the only nationally representative, continuing assessment of what U.S. students know and can do in various subject areas. NAEP provides a comprehensive measure of students' learning at critical junctures in their school experience. The…

  5. Ecosystem evapotranspiration: challenges in measurements, estimates, and modeling

    Treesearch

    Devendra Amatya; S. Irmak; P. Gowda; Ge Sun; J.E. Nettles; K.R. Douglas-Mankin

    2016-01-01

    Evapotranspiration (ET) processes at the leaf to landscape scales in multiple land uses have important controls and feedbacks for local, regional, and global climate and water resource systems. Innovative methods, tools, and technologies for improved understanding and quantification of ET and crop water use are critical for adapting more effective management strategies...

  6. Hierarchical models and bayesian analysis of bird survey information

    Treesearch

    John R. Sauer; William A. Link; J. Andrew Royle

    2005-01-01

    Summary of bird survey information is a critical component of conservation activities, but often our summaries rely on statistical methods that do not accommodate the limitations of the information. Prioritization of species requires ranking and analysis of species by magnitude of population trend, but often magnitude of trend is a misleading measure of actual decline...

  7. Multi-temporal LiDAR and Landsat quantification of fire-induced changes to forest structure

    Treesearch

    T. Ryan McCarley; Crystal A. Kolden; Nicole M. Vaillant; Andrew T. Hudak; Alistair M. S. Smith; Brian M. Wing; Bryce S. Kellogg; Jason Kreitler

    2017-01-01

    Measuring post-fire effects at landscape scales is critical to an ecological understanding of wildfire effects. Predominantly this is accomplished with either multi-spectral remote sensing data or through ground-based field sampling plots.While these methods are important, field data is usually limited to opportunistic post-fire observations, and spectral data often...

  8. Reliable Real-time Calculation of Heart-rate Complexity in Critically Ill Patients Using Multiple Noisy Waveform Sources

    DTIC Science & Technology

    2014-01-01

    systems Machine learning Automatic data processing 1 Introduction Heart-rate complexity (HRC) is a method of quantifying the amount of complex...5. Batchinsky AI, Skinner J, Necsoiu C, et al. New measures of heart-rate complexity: effect of chest trauma and hemorrhage. J Trauma. 2010;68:1178–85

  9. Long-term observations of crop water use with eddy covariance stations and coupling with crop simulation models

    USDA-ARS?s Scientific Manuscript database

    Understanding crop water use is critical to being able to determine crop water requirements and when water is limiting crop productivity. There have been many different techniques used to quantify crop water use and the eddy covariance approach is one method that has the capacity to measure crop wat...

  10. Managing What We Can Measure: Quantifying the Susceptibility of Automated Scoring Systems to Gaming Behavior

    ERIC Educational Resources Information Center

    Higgins, Derrick; Heilman, Michael

    2014-01-01

    As methods for automated scoring of constructed-response items become more widely adopted in state assessments, and are used in more consequential operational configurations, it is critical that their susceptibility to gaming behavior be investigated and managed. This article provides a review of research relevant to how construct-irrelevant…

  11. Evaluating Indicator-Based Methods of "Measuring Long-Term Impacts of a Science Center on Its Community"

    ERIC Educational Resources Information Center

    Jensen, Eric Allen

    2016-01-01

    This article addresses some of the challenges faced when attempting to evaluate the long-term impact of informal science learning interventions. To contribute to the methodological development of informal science learning research, we critically examine (Falk and Needham (2011) "Journal of Research in Science Teaching," 48: 1-12.) study…

  12. Cross-Cultural Adaptation of a Pre-School Screening Instrument: Comparison of Korean and US Populations

    ERIC Educational Resources Information Center

    Heo, K. H.; Squires, J.; Yovanoff, P.

    2008-01-01

    Background: Accurate and efficient developmental screening measures are critical for early identification of developmental problems; however, few reliable and valid tests are available in Korea as well as other countries outside the USA. The Ages and Stages Questionnaires (ASQ) was chosen for study with young children in Korea. Methods: The ASQ…

  13. Using a Combination of Experimental and Mathematical Method to Explore Critical Micelle Concentration of a Cationic Surfactant

    ERIC Educational Resources Information Center

    Goronja, Jelena; Pejic´, Natas?a; Lez?aic´, Aleksandra Janos?evic´; Stanisavljev, Dragomir; Malenovic, Andelija

    2016-01-01

    An undergraduate electrical conductivity measurement experiment in a physical chemistry lab and basic fitting procedures are presented that allow a characterization of micellar system of hexadecyltrimethylammonium bromide (cetyltrimethylammonium bromide, CTAB) in binary mixture of water and acetonitrile (ACN) as a cosolvent (10%, v/v) at 30.0 °C.…

  14. Interpreting landscape change: measured biophysical change and surrounding social context

    Treesearch

    Mimi M. Wagner; Paul H. Gobster

    2007-01-01

    Although research assessing both biophysical landscape conditions and social perceptions provide critical data on change, these methods are seldom integrated. In this study, we examined landscape change in the Central Iowa region by pairing quantitative data on changes to natural areas, streams, and housing density over the past 60 years with a qualitative social...

  15. Segmented-field radiography in scoliosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel, W.W.; Barnes, G.T.; Nasca, R.J.

    1985-02-01

    A method of scoliosis imaging using segmented fields is presented. The method is advantageous for patients requiring serial radiographic monitoring, as it results in markedly reduced radiation doses to critical organs, particularly the breast. Absorbed dose to the breast was measured to be 8.8 mrad (88 ..mu..Gy) for a full-field examination and 0.051 mrad (5.1 ..mu..Gy) for the segmented-field study. The segmented-field technique also results in improved image quality. Experience with 53 studies in 23 patients is reported.

  16. Methodological considerations in service use assessment for children and youth with mental health conditions; issues for economic evaluation.

    PubMed

    Woolderink, M; Lynch, F L; van Asselt, A D I; Beecham, J; Evers, S M A A; Paulus, A T G; van Schayck, C P

    2015-05-01

    Economic evaluations are increasingly used in decision-making. Accurate measurement of service use is critical to economic evaluation. This qualitative study, based on expert interviews, aims to identify best approaches to service use measurement for child mental health conditions, and to identify problems in current methods. Results suggest considerable agreement on strengths (e.g., availability of accurate instruments to measure service use) and weaknesses, (e.g., lack of unit prices for services outside the health sector) or alternative approaches to service use measurement. Experts also identified some unresolved problems, for example the lack of uniform definitions for some mental health services.

  17. Endogenous glutamine production in critically ill patients: the effect of exogenous glutamine supplementation

    PubMed Central

    2014-01-01

    Introduction Glutamine rate of appearance (Ra) may be used as an estimate of endogenous glutamine production. Recently a technique employing a bolus injection of isotopically labeled glutamine was introduced, with the potential to allow for multiple assessments of the glutamine Ra over time in critically ill patients, who may not be as metabolically stable as healthy individuals. Here the technique was used to evaluate the endogenous glutamine production in critically ill patients in the fed state with and without exogenous glutamine supplementation intravenously. Methods Mechanically ventilated patients (n = 11) in the intensive care unit (ICU) were studied on two consecutive days during continuous parenteral feeding. To allow the patients to be used as their own controls, they were randomized for the reference measurement during basal feeding without supplementation, before or after the supplementation period. Glutamine Ra was determined by a bolus injection of 13C-glutamine followed by a period of frequent sampling to establish the decay-curve for the glutamine tracer. Exogenous glutamine supplementation was given by intravenous infusion of a glutamine containing dipeptide, L-alanyl-L-glutamine, 0.28 g/kg during 20 hours. Results A 14% increase of endogenous glutamine Ra was seen at the end of the intravenous supplementation period as compared to the basal measurements (P = 0.009). Conclusions The bolus injection technique to measure glutamine Ra to estimate the endogenous production of glutamine in critically ill patients was demonstrated to be useful for repetitive measurements. The hypothesized attenuation of endogenous glutamine production during L-alanyl-L-glutamine infusion given as a part of full nutrition was not seen. PMID:24731231

  18. Contour metrology using critical dimension atomic force microscopy

    NASA Astrophysics Data System (ADS)

    Orji, Ndubuisi G.; Dixson, Ronald G.; Vladár, András E.; Ming, Bin; Postek, Michael T.

    2012-03-01

    The critical dimension atomic force microscope (CD-AFM), which is used as a reference instrument in lithography metrology, has been proposed as a complementary instrument for contour measurement and verification. Although data from CD-AFM is inherently three dimensional, the planar two-dimensional data required for contour metrology is not easily extracted from the top-down CD-AFM data. This is largely due to the limitations of the CD-AFM method for controlling the tip position and scanning. We describe scanning techniques and profile extraction methods to obtain contours from CD-AFM data. We also describe how we validated our technique, and explain some of its limitations. Potential sources of error for this approach are described, and a rigorous uncertainty model is presented. Our objective is to show which data acquisition and analysis methods could yield optimum contour information while preserving some of the strengths of CD-AFM metrology. We present comparison of contours extracted using our technique to those obtained from the scanning electron microscope (SEM), and the helium ion microscope (HIM).

  19. A critical analysis of one standard and five methods to monitor surface wetness and time-of-wetness

    NASA Astrophysics Data System (ADS)

    Camuffo, Dario; della Valle, Antonio; Becherini, Francesca

    2018-05-01

    Surface wetness is a synergistic factor to determine atmospheric corrosion, monument weathering, mould growth, sick buildings, etc. However, its detection and monitoring are neither easy nor homogeneous, for a number of factors that may affect readings. Various types of methods and sensors, either commercial or prototypes built in the lab, have been investigated and compared, i.e. the international standard ISO 9223 to evaluate corrosivity after wetness and time-of-wetness; indirect evaluation of wetness, based on the dew point calculated after the output of temperature and relative humidity sensors and direct measurements by means of capacitive wetness sensors, safety sensors, rain sensors (also known as leaf wetness sensors), infrared reflection sensors and fibre optic sensors. A comparison between the different methods is presented, specifying physical principles, forms of wetting to which they are respondent (i.e. condensation, ice melting, splashing drops, percolation and capillary rise), critical factors, use and cost.

  20. A study on suppressing transmittance fluctuations for air-gapped Glan-type polarizing prisms

    NASA Astrophysics Data System (ADS)

    Zhang, Chuanfa; Li, Dailin; Zhu, Huafeng; Li, Chuanzhi; Jiao, Zhiyong; Wang, Ning; Xu, Zhaopeng; Wang, Xiumin; Song, Lianke

    2018-05-01

    Light intensity transmittance is a key parameter for the design of polarizing prisms, while sometimes its experimental curves based on spatial incident angle presents periodical fluctuations. Here, we propose a novel method for completely suppressing these fluctuations via setting a glued error angle in the air gap of Glan-Taylor prisms. The proposal consists of: an accurate formula of the intensity transmittance for Glan-Taylor prisms, a numerical simulation and a contrast experiment of Glan-Taylor prisms for analyzing the causes of the fluctuations, and a simple method for accurately measuring the glued error angle. The result indicates that when the setting glued error angle is larger than the critical angle for a certain polarizing prism, the fluctuations can be completely suppressed, and a smooth intensity transmittance curve can be obtained. Besides, the critical angle in the air gap for suppressing the fluctuations is decreased with the increase of beam spot size. This method has the advantage of having less demand for the prism position in optical systems.

  1. Minimally invasive anterior pelvic internal fixation: An anatomic study comparing Pelvic Bridge to INFIX.

    PubMed

    Reichel, Lee M; MacCormick, Lauren M; Dugarte, Anthony J; Rizkala, Amir R; Graves, Sara C; Cole, Peter A

    2018-02-01

    Anterior external fixation for pelvic ring fractures has shown to effectively improve stability and reduce mortality. However, these fixators can be associated with substantial morbidity such as pin tract infection, premature loss of fixation, and decreased quality of life in patients. Recently, two new methods of subcutaneous anterior pelvic internal fixation have been developed; the INFIX and the Pelvic Bridge. These methods have the purported advantages of lower wound complications, less surgical site pain, and improved quality of life. We sought to investigate the measured distances to critical anatomic structures, as well as the qualitative and topographic differences notable during implantation of both devices in the same cadaveric specimen. The Pelvic Bridge and INFIX were implanted in eleven fresh cadavers. Distances were then measured to: the superficial inguinal ring, round ligament, spermatic cord, lateral femoral cutaneous nerve (LFCN), femoral nerve, femoral artery, and femoral vein. Observations regarding implantation and topography were also recorded. The INFIX had greater measured distances from all structures except for the LFCN, in which its proximity placed this structure at risk. Neither device appears to put other critical structures at risk in the supine position. Significant implantation and topographic differences exist between the devices. The INFIX application lacked "safety margins" concerning the LFCN in 10/11 (90.9%) specimens, while Pelvic Bridge placement lacked "safety margins" with regard to the right superficial ring (1/11, 9%) and the right spermatic cord (1/11, 9%). Both the Pelvic Bridge and INFIX lie at safe distances from most critical pelvic structures in the supine position, though INFIX application places the LFCN at risk. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Susceptibility Measurements Near the He-3 Liquid-Gas Critical Point

    NASA Technical Reports Server (NTRS)

    Barmatz, Martin; Zhong, Fang; Hahn, Inseob

    2000-01-01

    An experiment is now being developed to measure both the linear susceptibility and specific heat at constant volume near the liquid-gas critical point of He-3 in a microgravity environment. An electrostriction technique for measuring susceptibility will be described. Initial electrostriction measurements were performed on the ground along the critical isochore in a 0.5 mm high measurement cell filled to within 0.1 % of the critical density. These measurements agreed with the susceptibility determined from pressure-density measurements along isotherms. The critical temperature, T(sub c), determined separately from specific heat and susceptibility measurements was self-consistent. Susceptibility measurements in the range t = T/T(sub c) - 1 > 10(exp -4)were fit to Chi(sup *)(sub T) = Gamma(sup +)t(exp -lambda)(1 + Gamma(sup +)(sub 1)t(sup delta). Best fit parameters for the asymptotic amplitude Gamma(sup +) and the first Wegner amplitude Gamma(sup +)(sub 1) will be presented and compared to previous measurements.

  3. Nutritional risk assessment in critically ill cancer patients: systematic review

    PubMed Central

    Fruchtenicht, Ana Valéria Gonçalves; Poziomyck, Aline Kirjner; Kabke, Geórgia Brum; Loss, Sérgio Henrique; Antoniazzi, Jorge Luiz; Steemburgo, Thais; Moreira, Luis Fernando

    2015-01-01

    Objective To systematically review the main methods for nutritional risk assessment used in critically ill cancer patients and present the methods that better assess risks and predict relevant clinical outcomes in this group of patients, as well as to discuss the pros and cons of these methods according to the current literature. Methods The study consisted of a systematic review based on analysis of manuscripts retrieved from the PubMed, LILACS and SciELO databases by searching for the key words “nutritional risk assessment”, “critically ill” and “cancer”. Results Only 6 (17.7%) of 34 initially retrieved papers met the inclusion criteria and were selected for the review. The main outcomes of these studies were that resting energy expenditure was associated with undernourishment and overfeeding. The high Patient-Generated Subjective Global Assessment score was significantly associated with low food intake, weight loss and malnutrition. In terms of biochemical markers, higher levels of creatinine, albumin and urea were significantly associated with lower mortality. The worst survival was found for patients with worse Eastern Cooperative Oncologic Group - performance status, high Glasgow Prognostic Score, low albumin, high Patient-Generated Subjective Global Assessment score and high alkaline phosphatase levels. Geriatric Nutritional Risk Index values < 87 were significantly associated with mortality. A high Prognostic Inflammatory and Nutritional Index score was associated with abnormal nutritional status in critically ill cancer patients. Among the reviewed studies that examined weight and body mass index alone, no significant clinical outcome was found. Conclusion None of the methods reviewed helped to define risk among these patients. Therefore, assessment by a combination of weight loss and serum measurements, preferably in combination with other methods using scores such as Eastern Cooperative Oncologic Group - performance status, Glasgow Prognostic Score and Patient-Generated Subjective Global Assessment, is suggested given that their use is simple, feasible and useful in such cases. PMID:26270855

  4. Stratospheric CCN sampling program

    NASA Technical Reports Server (NTRS)

    Rogers, C. F.

    1981-01-01

    When Mt. St. Helens produced several major eruptions in the late spring of 1980, there was a strong interest in the characterization of the cloud condensation nuclei (CCN) activity of the material that was injected into the troposphere and stratosphere. The scientific value of CCN measurements is two fold: CCN counts may be directly applied to calculations of the interaction of the aerosol (enlargement) at atmospherically-realistic relative humidities or supersaturations; and if the chemical constituency of the aerosol can be assumed, the number-versus-critical supersaturation spectrum may be converted into a dry aerosol size spectrum covering a size region not readily measured by other methods. The sampling method is described along with the instrumentation used in the experiments.

  5. A Reference Method for Measuring Emissions of SVOCs in ...

    EPA Pesticide Factsheets

    Semivolatile organic compounds (SVOCs) are indoor air pollutants that may may have significant adverse effects on human health, and emission of SVOCs from building materials and consumer products is of growing concern. Few chamber studies have been conducted due to the challenges associated with SVOC analysis and the lack of validation procedures. Thus there is an urgent need for a reliable and accurate chamber test method to verify the performance of these measurements. A reference method employing a specially-designed chamber and experimental protocol has been developed and is undergoing extensive evaluation. A pilot interlaboratory study (ILS) has been conducted with five laboratories performing chamber tests under identical conditions. Results showed inter-laboratory variations at 25% for SVOC emission rates, with greater agreement observed between intra-laboratory measurements for most of the participating laboratories. The measured concentration profiles also compared reasonably well to the mechanistic model, demonstrating the feasibility of the proposed reference method to independently assess laboratory performance and validate SVOC emission tests. There is an urgent need for improved understanding of the measurement uncertainties associated with SVOC emissions testing. The creation of specially-designed chambers and well-characterized materials serves as a critical prerequisite for improving the procedure used to measure SVOCs emitted from indoor

  6. Experimental approaches to assessing the impact of a cesium chloride radiological dispersal device

    USGS Publications Warehouse

    Lee, S.; Gibb, Snyder E.; Barzyk, J.; McGee, J.; Koenig, A.

    2008-01-01

    The US EPA, as a part of the Chemical, Biological, Radiological-Nuclear, and Explosives (CBRNE) Research and Technology Initiative (CRTI) project team, is currently working to assess the impacts of an urban radiological dispersion device (RDD) and to develop containment and decontamination strategies. Three efforts in this area are currently underway: development of a laboratory-scale cesium chloride deposition method to mimic a RDD; assessment of cesium (Cs) penetration depth and pathways in urban materials using two dimensional (2-D) mapping laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS); and experimental determination of distribution coefficients (kd) for Cs in water-building material systems. It is critical that, when performing laboratory-scale experiments to assess the fate of Cs from an RDD, the Cs particle deposition method mimics the RDD deposition. Once Cs particles are deposited onto urban surfaces, 2-D mapping of Cs concentrations using LA-ICP-MS is a critical tool for determining Cs transport pathways through these materials. Lastly, distribution coefficients are critical for understanding the transport of Cs in urban settings when direct measurements of its penetration depth are unavailable. An assessment of the newly developed deposition method along with preliminary results from the penetration experiments are presented in this paper.

  7. Phase transition of Surprise optimization in community detection

    NASA Astrophysics Data System (ADS)

    Xiang, Ju; Tang, Yan-Ni; Gao, Yuan-Yuan; Liu, Lang; Hao, Yi; Li, Jian-Ming; Zhang, Yan; Chen, Shi

    2018-02-01

    Community detection is one of important issues in the research of complex networks. In literatures, many methods have been proposed to detect community structures in the networks, while they also have the scope of application themselves. In this paper, we investigate an important measure for community detection, Surprise (Aldecoa and Marín, Sci. Rep. 3 (2013) 1060), by focusing on the critical points in the merging and splitting of communities. We firstly analyze the critical behavior of Surprise and give the phase diagrams in community-partition transition. The results show that the critical number of communities for Surprise has a super-exponential increase with the increase of the link-density difference, while it is close to that of Modularity for small difference between inter- and intra-community link densities. By directly optimizing Surprise, we experimentally test the results on various networks, following a series of comparisons with other classical methods, and further find that the heterogeneity of networks could quicken the splitting of communities. On the whole, the results show that Surprise tends to split communities due to various reasons such as the heterogeneity in link density, degree and community size, and it thus exhibits higher resolution than other methods, e.g., Modularity, in community detection. Finally, we provide several approaches for enhancing Surprise.

  8. Bureau of Mines method of calibrating a primary radon-measuring apparatus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holub, R.R.; Stroud, W.P.

    1990-01-01

    One important requirement for accurate monitoring of radon in working environments, dwellings, and outdoors is to ensure that the measurement instrumentation is properly calibrated against a recognized standard. To achieve this goal, the U.S. Department of Interior Bureau of Mines (BoM) Radiation Laboratory has participated since 1983 in a program to establish international radon measurement standards. While the National Institute of Standards and Technology (NIST) radium solution ampules are acceptable to all participating laboratories as a primary standard, a method of transferring radon from the NIST source into each laboratory's primary counting apparatus is a critical problem. The Bureau's methodmore » transfers radon from the primary solution by bubbling 3 L of air through it into a steel cylinder. After homogenizing the radon concentrations in the cylinder, eight alpha-scintillation cells are filled consecutively and measured in a standard counting system. The resulting efficiency is 81.7 + or - 1.2%.« less

  9. [Clinical reasoning in undergraduate nursing education: a scoping review].

    PubMed

    Menezes, Sáskia Sampaio Cipriano de; Corrêa, Consuelo Garcia; Silva, Rita de Cássia Gengo E; Cruz, Diná de Almeida Monteiro Lopes da

    2015-12-01

    This study aimed at analyzing the current state of knowledge on clinical reasoning in undergraduate nursing education. A systematic scoping review through a search strategy applied to the MEDLINE database, and an analysis of the material recovered by extracting data done by two independent reviewers. The extracted data were analyzed and synthesized in a narrative manner. From the 1380 citations retrieved in the search, 23 were kept for review and their contents were summarized into five categories: 1) the experience of developing critical thinking/clinical reasoning/decision-making process; 2) teaching strategies related to the development of critical thinking/clinical reasoning/decision-making process; 3) measurement of variables related to the critical thinking/clinical reasoning/decision-making process; 4) relationship of variables involved in the critical thinking/clinical reasoning/decision-making process; and 5) theoretical development models of critical thinking/clinical reasoning/decision-making process for students. The biggest challenge for developing knowledge on teaching clinical reasoning seems to be finding consistency between theoretical perspectives on the development of clinical reasoning and methodologies, methods, and procedures in research initiatives in this field.

  10. Using hot lab to increase pre-service physics teacher’s critical thinking skills related to the topic of RLC circuit

    NASA Astrophysics Data System (ADS)

    Malik, A.; Setiawan, A.; Suhandi, A.; Permanasari, A.; Samsudin, A.; Safitri, D.; Lisdiani, S. A. S.; Sapriadil, S.; Hermita, N.

    2018-05-01

    This research purposes to explore the used of Higher Order Thinking Laboratory (HOT-Lab) in enhancing the critical thinking skills of pre-service teachers related to the topic of Resistors, Inductors, Capacitor (RLC circuit). This study utilised a quasi-experiment method with Pretest-Posttest Control Group design. The sample of the study was 60 students that were divided into two groups covering in experiment and control group, consists of 30 students. The instrument for measuring critical thinking skills is essay test. Data has been analyzed using normalized gain average, effect size, and t-test. The results show that students’ critical thinking skills using the HOT Lab are higher than the verification lab. Using HOT-lab was implemented in the form of activity in the laboratory can improve high-order thinking skills. Hence, it was concluded that the use of HOT Lab had a greater impact on improving students’ critical thinking skills on RLC topic. Finally, HOT Lab can be used for other physics topics.

  11. Rapid incremental methods for the determination of serum iron and iron-binding capacity

    PubMed Central

    Beale, R. N.; Bostrom, J. O.; Taylor, R. F.

    1961-01-01

    Rapid methods depending on differential absorptiometry are described for the determination of the transferrin iron content and the latent iron-binding capacity of blood serum. Each determination requires as little as 0·5 ml. serum. The methods are well adapted for routine use in the `average' laboratory. Three or four sera may be completely analysed in 30 minutes. All operations are carried out in the cells or tubes used for the colorimetric measurements, no precipitation or heating being employed at any stage. Critical investigations of the reliability of the methods are attempted and ranges of normal values are included. PMID:13866116

  12. Comparison of acoustic doppler current profiler and Price AA mechanical current meter measurements made during the 2011 Mississippi River Flood

    USGS Publications Warehouse

    O'Brien, Patrick; Mueller, David; Pratt, Thad

    2012-01-01

    The Mississippi River and Tributaries project performed as designed during the historic 2011 Mississippi River flood, with many of the operational decisions based on discharge targets as opposed to stage. Measurement of discharge at the Tarbert Landing, Mississippi range provides critical information used in operational decisions for the floodways located in Louisiana. Historically, discharge measurements have been made using a Price AA current meter and the mid-section method, and a long record exists based on these types of measurements, including historical peak discharges. Discharge measurements made using an acoustic Doppler current profiler from a moving boat have been incorporated into the record since the mid 1990's, and are used along with the Price AA mid-section measurements. During the 2011 flood event, both methods were used and appeared to provide different results at times. The apparent differences between the measurement techniques are due to complex hydrodynamics at this location that created large spatial and temporal fluctuations in the flow. The data and analysis presented herein show the difference between the two methods to be within the expected accuracy of the measurements when the measurements are made concurrently. The observed fluctuations prevent valid comparisons of data collected sequentially or even with different observation durations.

  13. Evaluation of Maryland abutment scour equation through selected threshold velocity methods

    USGS Publications Warehouse

    Benedict, S.T.

    2010-01-01

    The U.S. Geological Survey, in cooperation with the Maryland State Highway Administration, used field measurements of scour to evaluate the sensitivity of the Maryland abutment scour equation to the critical (or threshold) velocity variable. Four selected methods for estimating threshold velocity were applied to the Maryland abutment scour equation, and the predicted scour to the field measurements were compared. Results indicated that performance of the Maryland abutment scour equation was sensitive to the threshold velocity with some threshold velocity methods producing better estimates of predicted scour than did others. In addition, results indicated that regional stream characteristics can affect the performance of the Maryland abutment scour equation with moderate-gradient streams performing differently from low-gradient streams. On the basis of the findings of the investigation, guidance for selecting threshold velocity methods for application to the Maryland abutment scour equation are provided, and limitations are noted.

  14. Critical Point Cancellation in 3D Vector Fields: Robustness and Discussion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skraba, Primoz; Rosen, Paul; Wang, Bei

    Vector field topology has been successfully applied to represent the structure of steady vector fields. Critical points, one of the essential components of vector field topology, play an important role in describing the complexity of the extracted structure. Simplifying vector fields via critical point cancellation has practical merit for interpreting the behaviors of complex vector fields such as turbulence. However, there is no effective technique that allows direct cancellation of critical points in 3D. This work fills this gap and introduces the first framework to directly cancel pairs or groups of 3D critical points in a hierarchical manner with amore » guaranteed minimum amount of perturbation based on their robustness, a quantitative measure of their stability. In addition, our framework does not require the extraction of the entire 3D topology, which contains non-trivial separation structures, and thus is computationally effective. Furthermore, our algorithm can remove critical points in any subregion of the domain whose degree is zero and handle complex boundary configurations, making it capable of addressing challenging scenarios that may not be resolved otherwise. Here, we apply our method to synthetic and simulation datasets to demonstrate its effectiveness.« less

  15. Critical Point Cancellation in 3D Vector Fields: Robustness and Discussion.

    PubMed

    Skraba, Primoz; Rosen, Paul; Wang, Bei; Chen, Guoning; Bhatia, Harsh; Pascucci, Valerio

    2016-02-29

    Vector field topology has been successfully applied to represent the structure of steady vector fields. Critical points, one of the essential components of vector field topology, play an important role in describing the complexity of the extracted structure. Simplifying vector fields via critical point cancellation has practical merit for interpreting the behaviors of complex vector fields such as turbulence. However, there is no effective technique that allows direct cancellation of critical points in 3D. This work fills this gap and introduces the first framework to directly cancel pairs or groups of 3D critical points in a hierarchical manner with a guaranteed minimum amount of perturbation based on their robustness, a quantitative measure of their stability. In addition, our framework does not require the extraction of the entire 3D topology, which contains non-trivial separation structures, and thus is computationally effective. Furthermore, our algorithm can remove critical points in any subregion of the domain whose degree is zero and handle complex boundary configurations, making it capable of addressing challenging scenarios that may not be resolved otherwise. We apply our method to synthetic and simulation datasets to demonstrate its effectiveness.

  16. Critical Point Cancellation in 3D Vector Fields: Robustness and Discussion

    DOE PAGES

    Skraba, Primoz; Rosen, Paul; Wang, Bei; ...

    2016-02-29

    Vector field topology has been successfully applied to represent the structure of steady vector fields. Critical points, one of the essential components of vector field topology, play an important role in describing the complexity of the extracted structure. Simplifying vector fields via critical point cancellation has practical merit for interpreting the behaviors of complex vector fields such as turbulence. However, there is no effective technique that allows direct cancellation of critical points in 3D. This work fills this gap and introduces the first framework to directly cancel pairs or groups of 3D critical points in a hierarchical manner with amore » guaranteed minimum amount of perturbation based on their robustness, a quantitative measure of their stability. In addition, our framework does not require the extraction of the entire 3D topology, which contains non-trivial separation structures, and thus is computationally effective. Furthermore, our algorithm can remove critical points in any subregion of the domain whose degree is zero and handle complex boundary configurations, making it capable of addressing challenging scenarios that may not be resolved otherwise. Here, we apply our method to synthetic and simulation datasets to demonstrate its effectiveness.« less

  17. Educating for Critical Thinking: Thought-Encouraging Questions in a Community of Inquiry

    ERIC Educational Resources Information Center

    Golding, Clinton

    2011-01-01

    This paper presents one method for educating for critical thinking in Higher Education. It elaborates Richard Paul's method of Socratic questioning to show how students can learn to be critical thinkers. This method combines and uses the wider pedagogical and critical thinking literature in a new way: it emphasises a thinking-encouraging approach…

  18. Perceptions of the use of critical thinking teaching methods.

    PubMed

    Kowalczyk, Nina; Hackworth, Ruth; Case-Smith, Jane

    2012-01-01

    To identify the perceived level of competence in teaching and assessing critical thinking skills and the difficulties facing radiologic science program directors in implementing student-centered teaching methods. A total of 692 program directors received an invitation to complete an electronic survey soliciting information regarding the importance of critical thinking skills, their confidence in applying teaching methods and assessing student performance, and perceived obstacles. Statistical analysis included descriptive data, correlation coefficients, and ANOVA. Responses were received from 317 participants indicating program directors perceive critical thinking to be an essential element in the education of the student; however, they identified several areas for improvement. A high correlation was identified between the program directors' perceived level of skill and their confidence in critical thinking, and between their perceived level of skill and ability to assess the students' critical thinking. Key barriers to implementing critical thinking teaching strategies were identified. Program directors value the importance of implementing critical thinking teaching methods and perceive a need for professional development in critical thinking educational methods. Regardless of the type of educational institution in which the academic program is located, the level of education held by the program director was a significant factor regarding perceived confidence in the ability to model critical thinking skills and the ability to assess student critical thinking skills.

  19. Prospects and Problems of Transferring Quality-Improvement Methods from Health Care to Social Services: Two Case Studies

    PubMed Central

    Neubeck, Truls; Elg, Mattias; Schneider, Thomas; Andersson-Gäre, Boel

    2014-01-01

    Introduction: This study examines the use of quality-improvement (QI) methods in social services. Particularly the key aspects—generalizable knowledge, interprofessional teamwork, and measurements—are studied in projects from the QI program Forum for Values in Sweden. Methods: This is a mixed-method case study. Two projects using standard QI methods and tools as used in health care were chosen as critical cases to highlight some problems and prospects with the use of QI in social services. The cases were analyzed through documented results and qualitative interviews with participants one year after the QI projects ended. Results: The social service QI projects led to measurable improvements when they used standard methods and tools for QI in health care. One year after the projects, the improvements were either not continuously measured or not reported in any infrastructure for measurements. The study reveals that social services differ from health care regarding the availability and use of evidence, the role of professional expertise, and infrastructure for measurements. Conclusions: We argue that QI methods as used in health care are applicable in social services and can lead to measurable improvements. The study gives valuable insights for QI, not only in social services but also in health care, on how to assess and sustain improvements when infrastructures for measurements are lacking. In addition, when one forms QI teams, the focus should be on functions instead of professions, and QI methods can be used to support implementation of evidence-based practice. PMID:24867549

  20. Critical analysis of the Bennett-Riedel attack on secure cryptographic key distributions via the Kirchhoff-Law-Johnson-noise scheme.

    PubMed

    Kish, Laszlo B; Abbott, Derek; Granqvist, Claes G

    2013-01-01

    Recently, Bennett and Riedel (BR) (http://arxiv.org/abs/1303.7435v1) argued that thermodynamics is not essential in the Kirchhoff-law-Johnson-noise (KLJN) classical physical cryptographic exchange method in an effort to disprove the security of the KLJN scheme. They attempted to demonstrate this by introducing a dissipation-free deterministic key exchange method with two batteries and two switches. In the present paper, we first show that BR's scheme is unphysical and that some elements of its assumptions violate basic protocols of secure communication. All our analyses are based on a technically unlimited Eve with infinitely accurate and fast measurements limited only by the laws of physics and statistics. For non-ideal situations and at active (invasive) attacks, the uncertainly principle between measurement duration and statistical errors makes it impossible for Eve to extract the key regardless of the accuracy or speed of her measurements. To show that thermodynamics and noise are essential for the security, we crack the BR system with 100% success via passive attacks, in ten different ways, and demonstrate that the same cracking methods do not function for the KLJN scheme that employs Johnson noise to provide security underpinned by the Second Law of Thermodynamics. We also present a critical analysis of some other claims by BR; for example, we prove that their equations for describing zero security do not apply to the KLJN scheme. Finally we give mathematical security proofs for each BR-attack against the KLJN scheme and conclude that the information theoretic (unconditional) security of the KLJN method has not been successfully challenged.

Top