Sample records for critical test parameters

  1. A design of experiments test to define critical spray cleaning parameters for Brulin 815 GD and Jettacin cleaners

    NASA Technical Reports Server (NTRS)

    Keen, Jill M.; Evans, Kurt B.; Schiffman, Robert L.; Deweese, C. Darrell; Prince, Michael E.

    1995-01-01

    Experimental design testing was conducted to identify critical parameters of an aqueous spray process intended for cleaning solid rocket motor metal components (steel and aluminum). A two-level, six-parameter, fractional factorial matrix was constructed and conducted for two cleaners, Brulin 815 GD and Diversey Jettacin. The matrix parameters included cleaner temperature and concentration, wash density, wash pressure, rinse pressure, and dishwasher type. Other spray parameters: nozzle stand-off, rinse water temperature, wash and rinse time, dry conditions, and type of rinse water (deionized) were held constant. Matrix response testing utilized discriminating bond specimens (fracture energy and tensile adhesion strength) which represent critical production bond lines. Overall, Jettacin spray cleaning was insensitive to the range of conditions tested for all parameters and exhibited bond strengths significantly above the TCA test baseline for all bond lines tested. Brulin 815 was sensitive to cleaning temperature, but produced bond strengths above the TCA test baseline even at the lower temperatures. Ultimately, the experimental design database was utilized to recommend process parameter settings for future aqueous spray cleaning characterization work.

  2. Evaluation of FEM engineering parameters from insitu tests

    DOT National Transportation Integrated Search

    2001-12-01

    The study looked critically at insitu test methods (SPT, CPT, DMT, and PMT) as a means for developing finite element constitutive model input parameters. The first phase of the study examined insitu test derived parameters with laboratory triaxial te...

  3. Improving the quality of parameter estimates obtained from slug tests

    USGS Publications Warehouse

    Butler, J.J.; McElwee, C.D.; Liu, W.

    1996-01-01

    The slug test is one of the most commonly used field methods for obtaining in situ estimates of hydraulic conductivity. Despite its prevalence, this method has received criticism from many quarters in the ground-water community. This criticism emphasizes the poor quality of the estimated parameters, a condition that is primarily a product of the somewhat casual approach that is often employed in slug tests. Recently, the Kansas Geological Survey (KGS) has pursued research directed it improving methods for the performance and analysis of slug tests. Based on extensive theoretical and field research, a series of guidelines have been proposed that should enable the quality of parameter estimates to be improved. The most significant of these guidelines are: (1) three or more slug tests should be performed at each well during a given test period; (2) two or more different initial displacements (Ho) should be used at each well during a test period; (3) the method used to initiate a test should enable the slug to be introduced in a near-instantaneous manner and should allow a good estimate of Ho to be obtained; (4) data-acquisition equipment that enables a large quantity of high quality data to be collected should be employed; (5) if an estimate of the storage parameter is needed, an observation well other than the test well should be employed; (6) the method chosen for analysis of the slug-test data should be appropriate for site conditions; (7) use of pre- and post-analysis plots should be an integral component of the analysis procedure, and (8) appropriate well construction parameters should be employed. Data from slug tests performed at a number of KGS field sites demonstrate the importance of these guidelines.

  4. Effects of space environment on composites: An analytical study of critical experimental parameters

    NASA Technical Reports Server (NTRS)

    Gupta, A.; Carroll, W. F.; Moacanin, J.

    1979-01-01

    A generalized methodology currently employed at JPL, was used to develop an analytical model for effects of high-energy electrons and interactions between electron and ultraviolet effects. Chemical kinetic concepts were applied in defining quantifiable parameters; the need for determining short-lived transient species and their concentration was demonstrated. The results demonstrates a systematic and cost-effective means of addressing the issues and show qualitative and quantitative, applicable relationships between space radiation and simulation parameters. An equally important result is identification of critical initial experiments necessary to further clarify the relationships. Topics discussed include facility and test design; rastered vs. diffuse continuous e-beam; valid acceleration level; simultaneous vs. sequential exposure to different types of radiation; and interruption of test continuity.

  5. Critical parameters for sterilization of oil palm fruit by microwave irradiation

    NASA Astrophysics Data System (ADS)

    Sarah, Maya; Taib, M. R.

    2017-08-01

    Study to evaluate critical parameters for microwave irradiation to sterilize oil palm fruit was carried out at power density of 560 to 1120 W/kg. Critical parameters are important to ensure moisture loss during sterilization exceed the critical moisture (Mc) but less than maximum moisture (Mmax). Critical moisture in this study was determined according to dielectric loss factor of heated oil palm fruits at 2450 MHz. It was obtained from slope characterization of dielectric loss factor-vs-moisture loss curve. The Mc was used to indicate critical temperature (Tc) and critical time (tc) for microwave sterilization. To ensure moisture loss above critical value but not exceed maximum value, the combinations of time-temperature for sterilization of oil palm fruits by microwave irradiation were 6 min and 75°C to 17 min and 82°C respectively.

  6. Critical processes and parameters in the development of accident tolerant fuels drop-in capsule irradiation tests

    DOE PAGES

    Barrett, K. E.; Ellis, K. D.; Glass, C. R.; ...

    2015-12-01

    The goal of the Accident Tolerant Fuel (ATF) program is to develop the next generation of Light Water Reactor (LWR) fuels with improved performance, reliability, and safety characteristics during normal operations and accident conditions and with reduced waste generation. An irradiation test series has been defined to assess the performance of proposed ATF concepts under normal LWR operating conditions. The Phase I ATF irradiation test series is planned to be performed as a series of drop-in capsule tests to be irradiated in the Advanced Test Reactor (ATR) operated by the Idaho National Laboratory (INL). Design, analysis, and fabrication processes formore » ATR drop-in capsule experiment preparation are presented in this paper to demonstrate the importance of special design considerations, parameter sensitivity analysis, and precise fabrication and inspection techniques for figure innovative materials used in ATF experiment assemblies. A Taylor Series Method sensitivity analysis approach was used to identify the most critical variables in cladding and rodlet stress, temperature, and pressure calculations for design analyses. The results showed that internal rodlet pressure calculations are most sensitive to the fission gas release rate uncertainty while temperature calculations are most sensitive to cladding I.D. and O.D. dimensional uncertainty. The analysis showed that stress calculations are most sensitive to rodlet internal pressure uncertainties, however the results also indicated that the inside radius, outside radius, and internal pressure were all magnified as they propagate through the stress equation. This study demonstrates the importance for ATF concept development teams to provide the fabricators as much information as possible about the material properties and behavior observed in prototype testing, mock-up fabrication and assembly, and chemical and mechanical testing of the materials that may have been performed in the concept development phase

  7. Determination of Critical Parameters Based on the Intensity of Transmitted Light Around Gas-Liquid Interface: Critical Parameters of CO

    NASA Astrophysics Data System (ADS)

    Nakayama, Masaki; Katano, Hiroaki; Sato, Haruki

    2014-05-01

    A precise determination of the critical temperature and density for technically important fluids would be possible on the basis of the digital image for the visual observation of the phase boundary in the vicinity of the critical point since the sensitivity and resolution are higher than those of naked eyes. In addition, the digital image can avoid the personal uncertainty of an observer. A strong density gradient occurs in a sample cell at the critical point due to gravity. It was carefully assessed to determine the critical density, where the density profile in the sample cell can be observed from the luminance profile of a digital image. The density-gradient profile becomes symmetric at the critical point. One of the best fluids, whose thermodynamic properties have been measured with the highest reliability among technically important fluids, would be carbon dioxide. In order to confirm the reliability of the proposed method, the critical temperature and density of carbon dioxide were determined using the digital image. The critical temperature and density values of carbon dioxide are ( and ( kg m, respectively. The critical temperature and density values agree with the existing best values within estimated uncertainties. The reliability of the method was confirmed. The critical pressure, 7.3795 MPa, corresponding to the determined critical temperature of 304.143 K is also proposed. A new set of parameters for the vapor-pressure equation is also provided.

  8. Critical parameters of hard-core Yukawa fluids within the structural theory

    NASA Astrophysics Data System (ADS)

    Bahaa Khedr, M.; Osman, S. M.

    2012-10-01

    A purely statistical mechanical approach is proposed to account for the liquid-vapor critical point based on the mean density approximation (MDA) of the direct correlation function. The application to hard-core Yukawa (HCY) fluids facilitates the use of the series mean spherical approximation (SMSA). The location of the critical parameters for HCY fluid with variable intermolecular range is accurately calculated. Good agreement is observed with computer simulation results and with the inverse temperature expansion (ITE) predictions. The influence of the potential range on the critical parameters is demonstrated and the universality of the critical compressibility ratio is discussed. The behavior of the isochoric and isobaric heat capacities along the equilibrium line and the near vicinity of the critical point is discussed in details.

  9. Order parameter fluctuations at a buried quantum critical point

    PubMed Central

    Feng, Yejun; Wang, Jiyang; Jaramillo, R.; van Wezel, Jasper; Haravifard, S.; Srajer, G.; Liu, Y.; Xu, Z.-A.; Littlewood, P. B.; Rosenbaum, T. F.

    2012-01-01

    Quantum criticality is a central concept in condensed matter physics, but the direct observation of quantum critical fluctuations has remained elusive. Here we present an X-ray diffraction study of the charge density wave (CDW) in 2H-NbSe2 at high pressure and low temperature, where we observe a broad regime of order parameter fluctuations that are controlled by proximity to a quantum critical point. X-rays can track the CDW despite the fact that the quantum critical regime is shrouded inside a superconducting phase; and in contrast to transport probes, allow direct measurement of the critical fluctuations of the charge order. Concurrent measurements of the crystal lattice point to a critical transition that is continuous in nature. Our results confirm the long-standing expectations of enhanced quantum fluctuations in low-dimensional systems, and may help to constrain theories of the quantum critical Fermi surface. PMID:22529348

  10. Microstructure based simulations for prediction of flow curves and selection of process parameters for inter-critical annealing in DP steel

    NASA Astrophysics Data System (ADS)

    Deepu, M. J.; Farivar, H.; Prahl, U.; Phanikumar, G.

    2017-04-01

    Dual phase steels are versatile advanced high strength steels that are being used for sheet metal applications in automotive industry. It also has the potential for application in bulk components like gear. The inter-critical annealing in dual phase steels is one of the crucial steps that determine the mechanical properties of the material. Selection of the process parameters for inter-critical annealing, in particular, the inter-critical annealing temperature and time is important as it plays a major role in determining the volume fractions of ferrite and martensite, which in turn determines the mechanical properties. Selection of these process parameters to obtain a particular required mechanical property requires large number of experimental trials. Simulation of microstructure evolution and virtual compression/tensile testing can help in reducing the number of such experimental trials. In the present work, phase field modeling implemented in the commercial software Micress® is used to predict the microstructure evolution during inter-critical annealing. Virtual compression tests are performed on the simulated microstructure using finite element method implemented in the commercial software, to obtain the effective flow curve of the macroscopic material. The flow curves obtained by simulation are experimentally validated with physical simulation in Gleeble® and compared with that obtained using linear rule of mixture. The methodology could be used in determining the inter-critical annealing process parameters required for achieving a particular flow curve.

  11. An Improved Method to Control the Critical Parameters of a Multivariable Control System

    NASA Astrophysics Data System (ADS)

    Subha Hency Jims, P.; Dharmalingam, S.; Wessley, G. Jims John

    2017-10-01

    The role of control systems is to cope with the process deficiencies and the undesirable effect of the external disturbances. Most of the multivariable processes are highly iterative and complex in nature. Aircraft systems, Modern Power Plants, Refineries, Robotic systems are few such complex systems that involve numerous critical parameters that need to be monitored and controlled. Control of these important parameters is not only tedious and cumbersome but also is crucial from environmental, safety and quality perspective. In this paper, one such multivariable system, namely, a utility boiler has been considered. A modern power plant is a complex arrangement of pipework and machineries with numerous interacting control loops and support systems. In this paper, the calculation of controller parameters based on classical tuning concepts has been presented. The controller parameters thus obtained and employed has controlled the critical parameters of a boiler during fuel switching disturbances. The proposed method can be applied to control the critical parameters like elevator, aileron, rudder, elevator trim rudder and aileron trim, flap control systems of aircraft systems.

  12. Determination of fiber-matrix interface failure parameters from off-axis tests

    NASA Technical Reports Server (NTRS)

    Naik, Rajiv A.; Crews, John H., Jr.

    1993-01-01

    Critical fiber-matrix (FM) interface strength parameters were determined using a micromechanics-based approach together with failure data from off-axis tension (OAT) tests. The ply stresses at failure for a range of off-axis angles were used as input to a micromechanics analysis that was performed using the personal computer-based MICSTRAN code. FM interface stresses at the failure loads were calculated for both the square and the diamond array models. A simple procedure was developed to determine which array had the more severe FM interface stresses and the location of these critical stresses on the interface. For the cases analyzed, critical FM interface stresses were found to occur with the square array model and were located at a point where adjacent fibers were closest together. The critical FM interface stresses were used together with the Tsai-Wu failure theory to determine a failure criterion for the FM interface. This criterion was then used to predict the onset of ply cracking in angle-ply laminates for a range of laminate angles. Predictions for the onset of ply cracking in angle-ply laminates agreed with the test data trends.

  13. Testing critical point universality along the λ-line

    NASA Astrophysics Data System (ADS)

    Nissen, J. A.; Swanson, D. R.; Geng, Z. K.; Dohm, V.; Israelsson, U. E.; DiPirro, M. J.; Lipa, J. A.

    1998-02-01

    We are currently building a prototype for a new test of critical-point universality at the lambda transition in 4He, which is to be performed in microgravity conditions. The flight experiment will measure the second-sound velocity as a function of temperature at pressures from 1 to 30 bars in the region close to the lambda line. The critical exponents and other parameters characterizing the behavior of the superfluid density will be determined from the measurements. The microgravity measurements will be quite extensive, probably taking 30 days to complete. In addition to the superfluid density, some measurements of the specific heat will be made using the low-g simulator at the Jet Propulsion Laboratory. The results of the superfluid density and specific heat measurements will be used to compare the asymptotic exponents and other universal aspects of the superfluid density with the theoretical predictions currently established by renormalization group techniques.

  14. Improving tablet coating robustness by selecting critical process parameters from retrospective data.

    PubMed

    Galí, A; García-Montoya, E; Ascaso, M; Pérez-Lozano, P; Ticó, J R; Miñarro, M; Suñé-Negre, J M

    2016-09-01

    Although tablet coating processes are widely used in the pharmaceutical industry, they often lack adequate robustness. Up-scaling can be challenging as minor changes in parameters can lead to varying quality results. To select critical process parameters (CPP) using retrospective data of a commercial product and to establish a design of experiments (DoE) that would improve the robustness of the coating process. A retrospective analysis of data from 36 commercial batches. Batches were selected based on the quality results generated during batch release, some of which revealed quality deviations concerning the appearance of the coated tablets. The product is already marketed and belongs to the portfolio of a multinational pharmaceutical company. The Statgraphics 5.1 software was used for data processing to determine critical process parameters in order to propose new working ranges. This study confirms that it is possible to determine the critical process parameters and create design spaces based on retrospective data of commercial batches. This type of analysis is thus converted into a tool to optimize the robustness of existing processes. Our results show that a design space can be established with minimum investment in experiments, since current commercial batch data are processed statistically.

  15. Reactor Testing and Qualification: Prioritized High-level Criticality Testing Needs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S. Bragg-Sitton; J. Bess; J. Werner

    2011-09-01

    Researchers at the Idaho National Laboratory (INL) were tasked with reviewing possible criticality testing needs to support development of the fission surface power system reactor design. Reactor physics testing can provide significant information to aid in development of technologies associated with small, fast spectrum reactors that could be applied for non-terrestrial power systems, leading to eventual system qualification. Several studies have been conducted in recent years to assess the data and analyses required to design and build a space fission power system with high confidence that the system will perform as designed [Marcille, 2004a, 2004b; Weaver, 2007; Parry et al.,more » 2008]. This report will provide a summary of previous critical tests and physics measurements that are potentially applicable to the current reactor design (both those that have been benchmarked and those not yet benchmarked), summarize recent studies of potential nuclear testing needs for space reactor development and their applicability to the current baseline fission surface power (FSP) system design, and provide an overview of a suite of tests (separate effects, sub-critical or critical) that could fill in the information database to improve the accuracy of physics modeling efforts as the FSP design is refined. Some recommendations for tasks that could be completed in the near term are also included. Specific recommendations on critical test configurations will be reserved until after the sensitivity analyses being conducted by Los Alamos National Laboratory (LANL) are completed (due August 2011).« less

  16. Critical state of sand matrix soils.

    PubMed

    Marto, Aminaton; Tan, Choy Soon; Makhtar, Ahmad Mahir; Kung Leong, Tiong

    2014-01-01

    The Critical State Soil Mechanic (CSSM) is a globally recognised framework while the critical states for sand and clay are both well established. Nevertheless, the development of the critical state of sand matrix soils is lacking. This paper discusses the development of critical state lines and corresponding critical state parameters for the investigated material, sand matrix soils using sand-kaolin mixtures. The output of this paper can be used as an interpretation framework for the research on liquefaction susceptibility of sand matrix soils in the future. The strain controlled triaxial test apparatus was used to provide the monotonic loading onto the reconstituted soil specimens. All tested soils were subjected to isotropic consolidation and sheared under undrained condition until critical state was ascertain. Based on the results of 32 test specimens, the critical state lines for eight different sand matrix soils were developed together with the corresponding values of critical state parameters, M, λ, and Γ. The range of the value of M, λ, and Γ is 0.803-0.998, 0.144-0.248, and 1.727-2.279, respectively. These values are comparable to the critical state parameters of river sand and kaolin clay. However, the relationship between fines percentages and these critical state parameters is too scattered to be correlated.

  17. Critical State of Sand Matrix Soils

    PubMed Central

    Marto, Aminaton; Tan, Choy Soon; Makhtar, Ahmad Mahir; Kung Leong, Tiong

    2014-01-01

    The Critical State Soil Mechanic (CSSM) is a globally recognised framework while the critical states for sand and clay are both well established. Nevertheless, the development of the critical state of sand matrix soils is lacking. This paper discusses the development of critical state lines and corresponding critical state parameters for the investigated material, sand matrix soils using sand-kaolin mixtures. The output of this paper can be used as an interpretation framework for the research on liquefaction susceptibility of sand matrix soils in the future. The strain controlled triaxial test apparatus was used to provide the monotonic loading onto the reconstituted soil specimens. All tested soils were subjected to isotropic consolidation and sheared under undrained condition until critical state was ascertain. Based on the results of 32 test specimens, the critical state lines for eight different sand matrix soils were developed together with the corresponding values of critical state parameters, M, λ, and Γ. The range of the value of M, λ, and Γ is 0.803–0.998, 0.144–0.248, and 1.727–2.279, respectively. These values are comparable to the critical state parameters of river sand and kaolin clay. However, the relationship between fines percentages and these critical state parameters is too scattered to be correlated. PMID:24757417

  18. The 4-parameter Compressible Packing Model (CPM) including a critical cavity size ratio

    NASA Astrophysics Data System (ADS)

    Roquier, Gerard

    2017-06-01

    The 4-parameter Compressible Packing Model (CPM) has been developed to predict the packing density of mixtures constituted by bidisperse spherical particles. The four parameters are: the wall effect and the loosening effect coefficients, the compaction index and a critical cavity size ratio. The two geometrical interactions have been studied theoretically on the basis of a spherical cell centered on a secondary class bead. For the loosening effect, a critical cavity size ratio, below which a fine particle can be inserted into a small cavity created by touching coarser particles, is introduced. This is the only parameter which requires adaptation to extend the model to other types of particles. The 4-parameter CPM demonstrates its efficiency on frictionless glass beads (300 values), spherical particles numerically simulated (20 values), round natural particles (125 values) and crushed particles (335 values) with correlation coefficients equal to respectively 99.0%, 98.7%, 97.8%, 96.4% and mean deviations equal to respectively 0.007, 0.006, 0.007, 0.010.

  19. 40 CFR 761.389 - Testing parameter requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Testing parameter requirements. 761.389 Section 761.389 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC... Under § 761.79(d)(4) § 761.389 Testing parameter requirements. There are no restrictions on the...

  20. 40 CFR 761.389 - Testing parameter requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Testing parameter requirements. 761.389 Section 761.389 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC... Under § 761.79(d)(4) § 761.389 Testing parameter requirements. There are no restrictions on the...

  1. Terrestrial photovoltaic cell process testing

    NASA Technical Reports Server (NTRS)

    Burger, D. R.

    1985-01-01

    The paper examines critical test parameters, criteria for selecting appropriate tests, and the use of statistical controls and test patterns to enhance PV-cell process test results. The coverage of critical test parameters is evaluated by examining available test methods and then screening these methods by considering the ability to measure those critical parameters which are most affected by the generic process, the cost of the test equipment and test performance, and the feasibility for process testing.

  2. Terrestrial photovoltaic cell process testing

    NASA Astrophysics Data System (ADS)

    Burger, D. R.

    The paper examines critical test parameters, criteria for selecting appropriate tests, and the use of statistical controls and test patterns to enhance PV-cell process test results. The coverage of critical test parameters is evaluated by examining available test methods and then screening these methods by considering the ability to measure those critical parameters which are most affected by the generic process, the cost of the test equipment and test performance, and the feasibility for process testing.

  3. Adapting the Critical Thinking Assessment Test for Palestinian Universities

    ERIC Educational Resources Information Center

    Basha, Sami; Drane, Denise; Light, Gregory

    2016-01-01

    Critical thinking is a key learning outcome for Palestinian students. However, there are no validated critical thinking tests in Arabic. Suitability of the US developed Critical Thinking Assessment Test (CAT) for use in Palestine was assessed. The test was piloted with university students in English (n = 30) and 4 questions were piloted in Arabic…

  4. Validation of a clinical critical thinking skills test in nursing.

    PubMed

    Shin, Sujin; Jung, Dukyoo; Kim, Sungeun

    2015-01-27

    The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability.

  5. The Generalized Higher Criticism for Testing SNP-Set Effects in Genetic Association Studies

    PubMed Central

    Barnett, Ian; Mukherjee, Rajarshi; Lin, Xihong

    2017-01-01

    It is of substantial interest to study the effects of genes, genetic pathways, and networks on the risk of complex diseases. These genetic constructs each contain multiple SNPs, which are often correlated and function jointly, and might be large in number. However, only a sparse subset of SNPs in a genetic construct is generally associated with the disease of interest. In this article, we propose the generalized higher criticism (GHC) to test for the association between an SNP set and a disease outcome. The higher criticism is a test traditionally used in high-dimensional signal detection settings when marginal test statistics are independent and the number of parameters is very large. However, these assumptions do not always hold in genetic association studies, due to linkage disequilibrium among SNPs and the finite number of SNPs in an SNP set in each genetic construct. The proposed GHC overcomes the limitations of the higher criticism by allowing for arbitrary correlation structures among the SNPs in an SNP-set, while performing accurate analytic p-value calculations for any finite number of SNPs in the SNP-set. We obtain the detection boundary of the GHC test. We compared empirically using simulations the power of the GHC method with existing SNP-set tests over a range of genetic regions with varied correlation structures and signal sparsity. We apply the proposed methods to analyze the CGEM breast cancer genome-wide association study. Supplementary materials for this article are available online. PMID:28736464

  6. A New Energy-Critical Plane Damage Parameter for Multiaxial Fatigue Life Prediction of Turbine Blades.

    PubMed

    Yu, Zheng-Yong; Zhu, Shun-Peng; Liu, Qiang; Liu, Yunhan

    2017-05-08

    As one of fracture critical components of an aircraft engine, accurate life prediction of a turbine blade to disk attachment is significant for ensuring the engine structural integrity and reliability. Fatigue failure of a turbine blade is often caused under multiaxial cyclic loadings at high temperatures. In this paper, considering different failure types, a new energy-critical plane damage parameter is proposed for multiaxial fatigue life prediction, and no extra fitted material constants will be needed for practical applications. Moreover, three multiaxial models with maximum damage parameters on the critical plane are evaluated under tension-compression and tension-torsion loadings. Experimental data of GH4169 under proportional and non-proportional fatigue loadings and a case study of a turbine disk-blade contact system are introduced for model validation. Results show that model predictions by Wang-Brown (WB) and Fatemi-Socie (FS) models with maximum damage parameters are conservative and acceptable. For the turbine disk-blade contact system, both of the proposed damage parameters and Smith-Watson-Topper (SWT) model show reasonably acceptable correlations with its field number of flight cycles. However, life estimations of the turbine blade reveal that the definition of the maximum damage parameter is not reasonable for the WB model but effective for both the FS and SWT models.

  7. A New Energy-Critical Plane Damage Parameter for Multiaxial Fatigue Life Prediction of Turbine Blades

    PubMed Central

    Yu, Zheng-Yong; Zhu, Shun-Peng; Liu, Qiang; Liu, Yunhan

    2017-01-01

    As one of fracture critical components of an aircraft engine, accurate life prediction of a turbine blade to disk attachment is significant for ensuring the engine structural integrity and reliability. Fatigue failure of a turbine blade is often caused under multiaxial cyclic loadings at high temperatures. In this paper, considering different failure types, a new energy-critical plane damage parameter is proposed for multiaxial fatigue life prediction, and no extra fitted material constants will be needed for practical applications. Moreover, three multiaxial models with maximum damage parameters on the critical plane are evaluated under tension-compression and tension-torsion loadings. Experimental data of GH4169 under proportional and non-proportional fatigue loadings and a case study of a turbine disk-blade contact system are introduced for model validation. Results show that model predictions by Wang-Brown (WB) and Fatemi-Socie (FS) models with maximum damage parameters are conservative and acceptable. For the turbine disk-blade contact system, both of the proposed damage parameters and Smith-Watson-Topper (SWT) model show reasonably acceptable correlations with its field number of flight cycles. However, life estimations of the turbine blade reveal that the definition of the maximum damage parameter is not reasonable for the WB model but effective for both the FS and SWT models. PMID:28772873

  8. Prepharmacy predictors of success in pharmacy school: grade point averages, pharmacy college admissions test, communication abilities, and critical thinking skills.

    PubMed

    Allen, D D; Bond, C A

    2001-07-01

    Good admissions decisions are essential for identifying successful students and good practitioners. Various parameters have been shown to have predictive power for academic success. Previous academic performance, the Pharmacy College Admissions Test (PCAT), and specific prepharmacy courses have been suggested as academic performance indicators. However, critical thinking abilities have not been evaluated. We evaluated the connection between academic success and each of the following predictive parameters: the California Critical Thinking Skills Test (CCTST) score, PCAT score, interview score, overall academic performance prior to admission at a pharmacy school, and performance in specific prepharmacy courses. We confirmed previous reports but demonstrated intriguing results in predicting practice-based skills. Critical thinking skills predict practice-based course success. Also, the CCTST and PCAT scores (Pearson correlation [pc] = 0.448, p < 0.001) were closely related in our students. The strongest predictors of practice-related courses and clerkship success were PCAT (pc=0.237, p<0.001) and CCTST (pc = 0.201, p < 0.001). These findings and other analyses suggest that PCAT may predict critical thinking skills in pharmacy practice courses and clerkships. Further study is needed to confirm this finding and determine which PCAT components predict critical thinking abilities.

  9. Validation of a clinical critical thinking skills test in nursing

    PubMed Central

    2015-01-01

    Purpose: The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. Methods: This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Results: Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. Conclusion: From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability. PMID:25622716

  10. Modelling decremental ramps using 2- and 3-parameter "critical power" models.

    PubMed

    Morton, R Hugh; Billat, Veronique

    2013-01-01

    The "Critical Power" (CP) model of human bioenergetics provides a valuable way to identify both limits of tolerance to exercise and mechanisms that underpin that tolerance. It applies principally to cycling-based exercise, but with suitable adjustments for analogous units it can be applied to other exercise modalities; in particular to incremental ramp exercise. It has not yet been applied to decremental ramps which put heavy early demand on the anaerobic energy supply system. This paper details cycling-based bioenergetics of decremental ramps using 2- and 3-parameter CP models. It derives equations that, for an individual of known CP model parameters, define those combinations of starting intensity and decremental gradient which will or will not lead to exhaustion before ramping to zero; and equations that predict time to exhaustion on those decremental ramps that will. These are further detailed with suitably chosen numerical and graphical illustrations. These equations can be used for parameter estimation from collected data, or to make predictions when parameters are known.

  11. Critical parameters in the production of ceramic pot filters for household water treatment in developing countries.

    PubMed

    Soppe, A I A; Heijman, S G J; Gensburger, I; Shantz, A; van Halem, D; Kroesbergen, J; Wubbels, G H; Smeets, P W M H

    2015-06-01

    The need to improve the access to safe water is generally recognized for the benefit of public health in developing countries. This study's objective was to identify critical parameters which are essential for improving the performance of ceramic pot filters (CPFs) as a point-of-use water treatment system. Defining critical production parameters was also relevant to confirm that CPFs with high-flow rates may have the same disinfection capacity as pots with normal flow rates. A pilot unit was built in Cambodia to produce CPFs under controlled and constant conditions. Pots were manufactured from a mixture of clay, laterite and rice husk in a small-scale, gas-fired, temperature-controlled kiln and tested for flow rate, removal efficiency of bacteria and material strength. Flow rate can be increased by increasing pore sizes and by increasing porosity. Pore sizes were increased by using larger rice husk particles and porosity was increased with larger proportions of rice husk in the clay mixture. The main conclusions: larger pore size decreases the removal efficiency of bacteria; higher porosity does not affect the removal efficiency of bacteria, but does influence the strength of pots; flow rates of CPFs can be raised to 10-20 L/hour without a significant decrease in bacterial removal efficiency.

  12. CRITICAL TESTS FOR PRT REACTOR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Triplett, J.R.; Anderson, J.K.; Dunn, R.E.

    1960-07-01

    Critical teste to be performed on the Plutonium Recycle Te st Heactor are described. Exponential, approach-tocritical, critical, and substitution experiments will be carried out. These experiments include: calibration of moderator level; determination of the wori of various fuel loadings; calibration of the shim system including determination of maximum control strength of the entire system; substitution experiments to determine reflector savings, void effects, effects of H/sub 2/O and degraded D/sub 2/O coolants, and effects of loop and other material intsllations; determination of fuel-plus-coolant and moderator temperature coefficients; and kinetic experiments to determine response of the reactor to reactivity changes. (M.C.G.)

  13. The Standardization of Tests: Criteria and Criticisms

    ERIC Educational Resources Information Center

    Weiner, Paul S.; Hoock, William C.

    1973-01-01

    Following a review of the procedures involved in the establishment of norms for standardized tests, the specific procedures used to establish norms for three tests commonly used in speech and language pathology are critically examined. (LS)

  14. Determination of deuterium–tritium critical burn-up parameter by four temperature theory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nazirzadeh, M.; Ghasemizad, A.; Khanbabei, B.

    Conditions for thermonuclear burn-up of an equimolar mixture of deuterium-tritium in non-equilibrium plasma have been investigated by four temperature theory. The photon distribution shape significantly affects the nature of thermonuclear burn. In three temperature model, the photon distribution is Planckian but in four temperature theory the photon distribution has a pure Planck form below a certain cut-off energy and then for photon energy above this cut-off energy makes a transition to Bose-Einstein distribution with a finite chemical potential. The objective was to develop four temperature theory in a plasma to calculate the critical burn up parameter which depends upon initialmore » density, the plasma components initial temperatures, and hot spot size. All the obtained results from four temperature theory model are compared with 3 temperature model. It is shown that the values of critical burn-up parameter calculated by four temperature theory are smaller than those of three temperature model.« less

  15. Training Test-Taking Skills: A Critical Analysis

    ERIC Educational Resources Information Center

    Fueyo, Vivian

    1977-01-01

    This review presents a critical analysis of the skills required for test-taking, the training of test-taking skills, and the experimental evidence on the training. Based on the recommendations of psychologists such as Thorndike, Cronbach, and McClelland, practical classroom strategies for test-taking are discussed. (Author)

  16. Vibroacoustic test plan evaluation: Parameter variation study

    NASA Technical Reports Server (NTRS)

    Stahle, C. V.; Gongloef, H. R.

    1976-01-01

    Statistical decision models are shown to provide a viable method of evaluating the cost effectiveness of alternate vibroacoustic test plans and the associated test levels. The methodology developed provides a major step toward the development of a realistic tool to quantitatively tailor test programs to specific payloads. Testing is considered at the no test, component, subassembly, or system level of assembly. Component redundancy and partial loss of flight data are considered. Most and probabilistic costs are considered, and incipient failures resulting from ground tests are treated. Optimums defining both component and assembly test levels are indicated for the modified test plans considered. modeling simplifications must be considered in interpreting the results relative to a particular payload. New parameters introduced were a no test option, flight by flight failure probabilities, and a cost to design components for higher vibration requirements. Parameters varied were the shuttle payload bay internal acoustic environment, the STS launch cost, the component retest/repair cost, and the amount of redundancy in the housekeeping section of the payload reliability model.

  17. Validating use of a critical thinking test for the dental admission test.

    PubMed

    Tsai, Tsung-Hsun

    2014-04-01

    The purpose of this study was to validate the use of a test to assess dental school applicants' critical thinking abilities. The intent was to include this test on the Dental Admission Test (DAT) if it was shown to enhance the DAT's validity. Correlation and regression analyses of undergraduate and dental school performance with scores on each of the tests on the DAT battery and the California Critical Thinking Skills Test (CCTST) were performed. Data were collected from 439 third- and fourth-year dental students who consented to participate and were enrolled at one of the ten accredited dental schools included in the study. These ten dental schools were from most regions of the United States. This study concluded that including the CCTST on the DAT did not significantly enhance the DAT's validity.

  18. Method of boundary testing of the electric circuits and its application for calculating electric tolerances. [electric equipment tests

    NASA Technical Reports Server (NTRS)

    Redkina, N. P.

    1974-01-01

    Boundary testing of electric circuits includes preliminary and limiting tests. Preliminary tests permit determination of the critical parameters causing the greatest deviation of the output parameter of the system. The boundary tests offer the possibility of determining the limits of the fitness of the system with simultaneous variation of its critical parameters.

  19. Static Magnetic Field Therapy: A Critical Review of Treatment Parameters

    PubMed Central

    Wahbeh, Helané; Harling, Noelle; Connelly, Erin; Schiffke, Heather C.; Forsten, Cora; Gregory, William L.; Markov, Marko S.; Souder, James J.; Elmer, Patricia; King, Valerie

    2009-01-01

    Static magnetic field (SMF) therapy, applied via a permanent magnet attached to the skin, is used by people worldwide for self-care. Despite a lack of established SMF dosage and treatment regimens, multiple studies are conducted to evaluate SMF therapy effectiveness. Our objectives in conducting this review are to:(i) summarize SMF research conducted in humans; (ii) critically evaluate reporting quality of SMF dosages and treatment parameters and (iii) propose a set of criteria for reporting SMF treatment parameters in future clinical trials. We searched 27 electronic databases and reference lists. Only English language human studies were included. Excluded were studies of electromagnetic fields, transcranial magnetic stimulation, magnets placed on acupuncture points, animal studies, abstracts, posters and editorials. Data were extracted on clinical indication, study design and 10 essential SMF parameters. Three reviewers assessed quality of reporting and calculated a quality assessment score for each of the 10 treatment parameters. Fifty-six studies were reviewed, 42 conducted in patient populations and 14 in healthy volunteers. The SMF treatment parameters most often and most completely described were site of application, magnet support device and frequency and duration of application. Least often and least completely described were characteristics of the SMF: magnet dimensions, measured field strength and estimated distance of the magnet from the target tissue. Thirty-four (61%) of studies failed to provide enough detail about SMF dosage to permit protocol replication by other investigators. Our findings highlight the need to optimize SMF dosing parameters for individual clinical conditions before proceeding to a full-scale clinical trial. PMID:18955243

  20. Preparing Students for Critical-Thinking Applications on Standardized Tests

    ERIC Educational Resources Information Center

    Hendricks, Jacquelyn Kaye

    2010-01-01

    Student performance on critical-thinking applications on standardized tests in a southwestern U.S. state has been low for several years. The purpose of this instrumental case study was to explore how one school district prepared students for critical-thinking applications on standardized tests. The study was informed by cognitivism and…

  1. Evaluating an Online Resourcefulness Training Intervention Pilot Test Using Six Critical Parameters.

    PubMed

    Musil, Carol M; Zauszniewski, Jaclene A; Burant, Christopher J; Toly, Valerie B; Warner, Camille B

    2015-12-01

    Few resources are available to help grandmother caregivers to grandchildren manage their complex family situations that may have immediate and long-term consequences for themselves and their families. Resourcefulness training is an intervention designed to help grandmothers improve their ability to deal with these problems. The purpose of this pilot study was to evaluate the necessity, feasibility, acceptability, fidelity, safety, and effectiveness (i.e., effect sizes) of an online, computer-based resourcefulness training intervention that was adapted from a face-to-face intervention. Twelve grandmothers raising or living with grandchildren participated in the pilot intervention that included (a) watching an instructional video on resourcefulness, (b) completing two online questionnaires over a 6-week time period, and (c) writing in an online journal every day for 4 weeks. Data are evaluated within the context of the six parameters important to intervention development. Qualitative and quantitative results provide initial support for all six parameters. Recommendations to improve aspects of the intervention are discussed. © The Author(s) 2015.

  2. Calibration of DEM parameters on shear test experiments using Kriging method

    NASA Astrophysics Data System (ADS)

    Bednarek, Xavier; Martin, Sylvain; Ndiaye, Abibatou; Peres, Véronique; Bonnefoy, Olivier

    2017-06-01

    Calibration of powder mixing simulation using Discrete-Element-Method is still an issue. Achieving good agreement with experimental results is difficult because time-efficient use of DEM involves strong assumptions. This work presents a methodology to calibrate DEM parameters using Efficient Global Optimization (EGO) algorithm based on Kriging interpolation method. Classical shear test experiments are used as calibration experiments. The calibration is made on two parameters - Young modulus and friction coefficient. The determination of the minimal number of grains that has to be used is a critical step. Simulations of a too small amount of grains would indeed not represent the realistic behavior of powder when using huge amout of grains will be strongly time consuming. The optimization goal is the minimization of the objective function which is the distance between simulated and measured behaviors. The EGO algorithm uses the maximization of the Expected Improvement criterion to find next point that has to be simulated. This stochastic criterion handles with the two interpolations made by the Kriging method : prediction of the objective function and estimation of the error made. It is thus able to quantify the improvement in the minimization that new simulations at specified DEM parameters would lead to.

  3. Two critical tests for the Critical Point earthquake

    NASA Astrophysics Data System (ADS)

    Tzanis, A.; Vallianatos, F.

    2003-04-01

    areas of negative stress transfer (stress shadows), i.e. the reverse effect which should be observed if energy was extracted from a fault system. In both cases the critical exponent of the accelerating sequence at the positive-stress-transfer regions is very close 0.25, consistent with the view of the fault network as a Self-Organizing Spinodal moving toward a first order phase transition. The reported observations are consistent with almost all of the theoretical predictions and expectations made in terms of the critical point / stress transfer model of seismogenesis. However, there are reservations as to whether they comprise bona-fide predictions. Time-to-failure modelling of accelerated seismicity is a relatively new field of study with few cases-histories whence to draw experience, most of which in fact comprise retrospective analyses of past earthquakes. Still, very little is known as to the development of real-time situations and their probability of success or failure. Also, the power-law scaling is essentially the result of a renormalisation, in which the process of failure at a small spatial scale and temporarily far from a global event can be remapped to the process of failure at a larger scale and closer to the global event. In consequence, when new elements are added, (i.e. large foreschocks), the sequence is renormalized and the predicted parameters may change, sometimes significantly. Yet another difficulty arises from the fact that even if a full-scale self-organising process is active in the critical area, it is not at all necessary that a large earthquake will occur as soon as the system enters the critical state. The critical point model merely predicts that past this time an earthquake is possible but not certain. The time of the large event may depend on several uncertain factors pertaining to the nucleation process, which may have significant time dependence of their own. Moreover, the stored energy may be dissipated with aseismic (low moment

  4. Which Test? Whose Scores? Comparing Standardized Critical Thinking Tests

    ERIC Educational Resources Information Center

    Hatcher, Donald L.

    2011-01-01

    In this article, after describing one approach for teaching critical thinking (CT) that was in place at Baker University from 1990 to 2008, the author describes their experience assessing CT using three standardized exams and shows why the choice of a standardized CT test can be problematic and the results misleading. These results can be…

  5. A Critical Review of the IELTS Writing Test

    ERIC Educational Resources Information Center

    Uysal, Hacer Hande

    2010-01-01

    Administered at local centres in 120 countries throughout the world, IELTS (International English Language Testing System) is one of the most widely used large-scale ESL tests that also offers a direct writing test component. Because of its popularity and its use for making critical decisions about test takers, it is crucial to draw attention to…

  6. Uncertainties in the Item Parameter Estimates and Robust Automated Test Assembly

    ERIC Educational Resources Information Center

    Veldkamp, Bernard P.; Matteucci, Mariagiulia; de Jong, Martijn G.

    2013-01-01

    Item response theory parameters have to be estimated, and because of the estimation process, they do have uncertainty in them. In most large-scale testing programs, the parameters are stored in item banks, and automated test assembly algorithms are applied to assemble operational test forms. These algorithms treat item parameters as fixed values,…

  7. Correlation of Electric Field and Critical Design Parameters for Ferroelectric Tunable Microwave Filters

    NASA Technical Reports Server (NTRS)

    Subramanyam, Guru; VanKeuls, Fred W.; Miranda, Felix A.; Canedy, Chadwick L.; Aggarwal, Sanjeev; Venkatesan, Thirumalai; Ramesh, Ramamoorthy

    2000-01-01

    The correlation of electric field and critical design parameters such as the insertion loss, frequency ability return loss, and bandwidth of conductor/ferroelectric/dielectric microstrip tunable K-band microwave filters is discussed in this work. This work is based primarily on barium strontium titanate (BSTO) ferroelectric thin film based tunable microstrip filters for room temperature applications. Two new parameters which we believe will simplify the evaluation of ferroelectric thin films for tunable microwave filters, are defined. The first of these, called the sensitivity parameter, is defined as the incremental change in center frequency with incremental change in maximum applied electric field (EPEAK) in the filter. The other, the loss parameter, is defined as the incremental or decremental change in insertion loss of the filter with incremental change in maximum applied electric field. At room temperature, the Au/BSTO/LAO microstrip filters exhibited a sensitivity parameter value between 15 and 5 MHz/cm/kV. The loss parameter varied for different bias configurations used for electrically tuning the filter. The loss parameter varied from 0.05 to 0.01 dB/cm/kV at room temperature.

  8. Measurement of the main and critical parameters for optimal laser treatment of heart disease

    NASA Astrophysics Data System (ADS)

    Kabeya, FB; Abrahamse, H.; Karsten, AE

    2017-10-01

    Laser light is frequently used in the diagnosis and treatment of patients. As in traditional treatments such as medication, bypass surgery, and minimally invasive ways, laser treatment can also fail and present serious side effects. The true reason for laser treatment failure or the side effects thereof, remains unknown. From the literature review conducted, and experimental results generated we conclude that an optimal laser treatment for coronary artery disease (named heart disease) can be obtained if certain critical parameters are correctly measured and understood. These parameters include the laser power, the laser beam profile, the fluence rate, the treatment time, as well as the absorption and scattering coefficients of the target treatment tissue. Therefore, this paper proposes different, accurate methods for the measurement of these critical parameters to determine the optimal laser treatment of heart disease with a minimal risk of side effects. The results from the measurement of absorption and scattering properties can be used in a computer simulation package to predict the fluence rate. The computing technique is a program based on the random number (Monte Carlo) process and probability statistics to track the propagation of photons through a biological tissue.

  9. Jordanian TEFL Graduate Students' Use of Critical Thinking Skills (as Measured by the Cornell Critical Thinking Test, Level Z)

    ERIC Educational Resources Information Center

    Bataineh, Ruba Fahmi; Zghoul, Lamma Hmoud

    2006-01-01

    This study investigates the critical thinking skills of 50 students currently enrolled in the Master's TEFL Programme at Yarmouk University, Jordan. The Cornell Critical Thinking Test, Level Z is utilised to test the students' use, or lack thereof, of the critical thinking skills of deduction, semantics, credibility, induction, definition and…

  10. Geotechnical Parameters of Alluvial Soils from in-situ Tests

    NASA Astrophysics Data System (ADS)

    Młynarek, Zbigniew; Stefaniak, Katarzyna; Wierzbicki, Jędrzej

    2012-10-01

    The article concentrates on the identification of geotechnical parameters of alluvial soil represented by silts found near Poznan and Elblag. Strength and deformation parameters of the subsoil tested were identified by the CPTU (static penetration) and SDMT (dilatometric) methods, as well as by the vane test (VT). Geotechnical parameters of the subsoil were analysed with a view to using the soil as an earth construction material and as a foundation for buildings constructed on the grounds tested. The article includes an analysis of the overconsolidation process of the soil tested and a formula for the identification of the overconsolidation ratio OCR. Equation 9 reflects the relation between the undrained shear strength and plasticity of the silts analyzed and the OCR value. The analysis resulted in the determination of the Nkt coefficient, which might be used to identify the undrained shear strength of both sediments tested. On the basis of a detailed analysis of changes in terms of the constrained oedometric modulus M0, the relations between the said modulus, the liquidity index and the OCR value were identified. Mayne's formula (1995) was used to determine the M0 modulus from the CPTU test. The usefullness of the sediments found near Poznan as an earth construction material was analysed after their structure had been destroyed and compacted with a Proctor apparatus. In cases of samples characterised by different water content and soil particle density, the analysis of changes in terms of cohesion and the internal friction angle proved that these parameters are influenced by the soil phase composition (Fig. 18 and 19). On the basis of the tests, it was concluded that the most desirable shear strength parameters are achieved when the silt is compacted below the optimum water content.

  11. Geotechnical Parameters of Alluvial Soils from in-situ Tests

    NASA Astrophysics Data System (ADS)

    Młynarek, Zbigniew; Stefaniak, Katarzyna; Wierzbicki, Jedrzej

    2012-10-01

    The article concentrates on the identification of geotechnical parameters of alluvial soil represented by silts found near Poznan and Elblag. Strength and deformation parameters of the subsoil tested were identified by the CPTU (static penetration) and SDMT (dilatometric) methods, as well as by the vane test (VT). Geotechnical parameters of the subsoil were analysed with a view to using the soil as an earth construction material and as a foundation for buildings constructed on the grounds tested. The article includes an analysis of the overconsolidation process of the soil tested and a formula for the identification of the overconsolidation ratio OCR. Equation 9 reflects the relation between the undrained shear strength and plasticity of the silts analyzed and the OCR value. The analysis resulted in the determination of the Nkt coefficient, which might be used to identify the undrained shear strength of both sediments tested. On the basis of a detailed analysis of changes in terms of the constrained oedometric modulus M0, the relations between the said modulus, the liquidity index and the OCR value were identified. Mayne's formula (1995) was used to determine the M0 modulus from the CPTU test. The usefullness of the sediments found near Poznan as an earth construction material was analysed after their structure had been destroyed and compacted with a Proctor apparatus. In cases of samples characterised by different water content and soil particle density, the analysis of changes in terms of cohesion and the internal friction angle proved that these parameters are influenced by the soil phase composition (Fig. 18 and 19). On the basis of the tests, it was concluded that the most desirable shear strength parameters are achieved when the silt is compacted below the optimum water content.

  12. Biochemical methane potential (BMP) tests: Reducing test time by early parameter estimation.

    PubMed

    Da Silva, C; Astals, S; Peces, M; Campos, J L; Guerrero, L

    2018-01-01

    Biochemical methane potential (BMP) test is a key analytical technique to assess the implementation and optimisation of anaerobic biotechnologies. However, this technique is characterised by long testing times (from 20 to >100days), which is not suitable for waste utilities, consulting companies or plants operators whose decision-making processes cannot be held for such a long time. This study develops a statistically robust mathematical strategy using sensitivity functions for early prediction of BMP first-order model parameters, i.e. methane yield (B 0 ) and kinetic constant rate (k). The minimum testing time for early parameter estimation showed a potential correlation with the k value, where (i) slowly biodegradable substrates (k≤0.1d -1 ) have a minimum testing times of ≥15days, (ii) moderately biodegradable substrates (0.1testing times between 8 and 15 days, and (iii) rapidly biodegradable substrates (k≥0.2d -1 ) have testing times lower than 7days. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Investigation of critical parameters controlling the efficiency of associative ionization

    NASA Astrophysics Data System (ADS)

    Le Padellec, A.; Launoy, T.; Dochain, A.; Urbain, X.

    2017-05-01

    This paper compiles our merged-beam experimental findings for the associative ionization (AI) process from charged reactants, with the aim of guiding future investigations with e.g. the double electrostatic ion storage ring DESIREE in Stockholm. A reinvestigation of the isotopic effect in H-(D-) + He+ collisions is presented, along with a review of {{{H}}}3+ and NO+ production by AI involving ion pairs or excited neutrals, and put in perspective with the mutual neutralization and radiative association reactions. Critical parameters are identified and evaluated for their systematic role in controlling the magnitude of the cross section: isotopic substitution, exothermicity, electronic state density, and spin statistics.

  14. Critical heat flux test apparatus

    DOEpatents

    Welsh, Robert E.; Doman, Marvin J.; Wilson, Edward C.

    1992-01-01

    An apparatus for testing, in situ, highly irradiated specimens at high temperature transients is provided. A specimen, which has a thermocouple device attached thereto, is manipulated into test position in a sealed quartz heating tube by a robot. An induction coil around a heating portion of the tube is powered by a radio frequency generator to heat the specimen. Sensors are connected to monitor the temperatures of the specimen and the induction coil. A quench chamber is located below the heating portion to permit rapid cooling of the specimen which is moved into this quench chamber once it is heated to a critical temperature. A vacuum pump is connected to the apparatus to collect any released fission gases which are analyzed at a remote location.

  15. A Review of the Effects on IRT Item Parameter Estimates with a Focus on Misbehaving Common Items in Test Equating

    PubMed Central

    Michaelides, Michalis P.

    2010-01-01

    Many studies have investigated the topic of change or drift in item parameter estimates in the context of item response theory (IRT). Content effects, such as instructional variation and curricular emphasis, as well as context effects, such as the wording, position, or exposure of an item have been found to impact item parameter estimates. The issue becomes more critical when items with estimates exhibiting differential behavior across test administrations are used as common for deriving equating transformations. This paper reviews the types of effects on IRT item parameter estimates and focuses on the impact of misbehaving or aberrant common items on equating transformations. Implications relating to test validity and the judgmental nature of the decision to keep or discard aberrant common items are discussed, with recommendations for future research into more informed and formal ways of dealing with misbehaving common items. PMID:21833230

  16. A Review of the Effects on IRT Item Parameter Estimates with a Focus on Misbehaving Common Items in Test Equating.

    PubMed

    Michaelides, Michalis P

    2010-01-01

    Many studies have investigated the topic of change or drift in item parameter estimates in the context of item response theory (IRT). Content effects, such as instructional variation and curricular emphasis, as well as context effects, such as the wording, position, or exposure of an item have been found to impact item parameter estimates. The issue becomes more critical when items with estimates exhibiting differential behavior across test administrations are used as common for deriving equating transformations. This paper reviews the types of effects on IRT item parameter estimates and focuses on the impact of misbehaving or aberrant common items on equating transformations. Implications relating to test validity and the judgmental nature of the decision to keep or discard aberrant common items are discussed, with recommendations for future research into more informed and formal ways of dealing with misbehaving common items.

  17. Drop-on-Demand System for Manufacturing of Melt-based Solid Oral Dosage: Effect of Critical Process Parameters on Product Quality.

    PubMed

    Içten, Elçin; Giridhar, Arun; Nagy, Zoltan K; Reklaitis, Gintaras V

    2016-04-01

    The features of a drop-on-demand-based system developed for the manufacture of melt-based pharmaceuticals have been previously reported. In this paper, a supervisory control system, which is designed to ensure reproducible production of high quality of melt-based solid oral dosages, is presented. This control system enables the production of individual dosage forms with the desired critical quality attributes: amount of active ingredient and drug morphology by monitoring and controlling critical process parameters, such as drop size and product and process temperatures. The effects of these process parameters on the final product quality are investigated, and the properties of the produced dosage forms characterized using various techniques, such as Raman spectroscopy, optical microscopy, and dissolution testing. A crystallization temperature control strategy, including controlled temperature cycles, is presented to tailor the crystallization behavior of drug deposits and to achieve consistent drug morphology. This control strategy can be used to achieve the desired bioavailability of the drug by mitigating variations in the dissolution profiles. The supervisor control strategy enables the application of the drop-on-demand system to the production of individualized dosage required for personalized drug regimens.

  18. Theory of Metastable State Relaxation for Non-Critical Binary Systems with Non-Conserved Order Parameter

    NASA Technical Reports Server (NTRS)

    Izmailov, Alexander; Myerson, Allan S.

    1993-01-01

    A new mathematical ansatz for a solution of the time-dependent Ginzburg-Landau non-linear partial differential equation is developed for non-critical systems such as non-critical binary solutions (solute + solvent) described by the non-conserved scalar order parameter. It is demonstrated that in such systems metastability initiates heterogeneous solute redistribution which results in formation of the non-equilibrium singly-periodic spatial solute structure. It is found how the time-dependent period of this structure evolves in time. In addition, the critical radius r(sub c) for solute embryo of the new solute rich phase together with the metastable state lifetime t(sub c) are determined analytically and analyzed.

  19. Parameter estimation with Sandage-Loeb test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geng, Jia-Jia; Zhang, Jing-Fei; Zhang, Xin, E-mail: gengjiajia163@163.com, E-mail: jfzhang@mail.neu.edu.cn, E-mail: zhangxin@mail.neu.edu.cn

    2014-12-01

    The Sandage-Loeb (SL) test directly measures the expansion rate of the universe in the redshift range of 2 ∼< z ∼< 5 by detecting redshift drift in the spectra of Lyman-α forest of distant quasars. We discuss the impact of the future SL test data on parameter estimation for the ΛCDM, the wCDM, and the w{sub 0}w{sub a}CDM models. To avoid the potential inconsistency with other observational data, we take the best-fitting dark energy model constrained by the current observations as the fiducial model to produce 30 mock SL test data. The SL test data provide an important supplement to the other dark energymore » probes, since they are extremely helpful in breaking the existing parameter degeneracies. We show that the strong degeneracy between Ω{sub m} and H{sub 0} in all the three dark energy models is well broken by the SL test. Compared to the current combined data of type Ia supernovae, baryon acoustic oscillation, cosmic microwave background, and Hubble constant, the 30-yr observation of SL test could improve the constraints on Ω{sub m} and H{sub 0} by more than 60% for all the three models. But the SL test can only moderately improve the constraint on the equation of state of dark energy. We show that a 30-yr observation of SL test could help improve the constraint on constant w by about 25%, and improve the constraints on w{sub 0} and w{sub a} by about 20% and 15%, respectively. We also quantify the constraining power of the SL test in the future high-precision joint geometric constraints on dark energy. The mock future supernova and baryon acoustic oscillation data are simulated based on the space-based project JDEM. We find that the 30-yr observation of SL test would help improve the measurement precision of Ω{sub m}, H{sub 0}, and w{sub a} by more than 70%, 20%, and 60%, respectively, for the w{sub 0}w{sub a}CDM model.« less

  20. On the identification of cohesive parameters for printed metal-polymer interfaces

    NASA Astrophysics Data System (ADS)

    Heinrich, Felix; Langner, Hauke H.; Lammering, Rolf

    2017-05-01

    The mechanical behavior of printed electronics on fiber reinforced composites is investigated. A methodology based on cohesive zone models is employed, considering interfacial strengths, stiffnesses and critical strain energy release rates. A double cantilever beam test and an end notched flexure test are carried out to experimentally determine critical strain energy release rates under fracture modes I and II. Numerical simulations are performed in Abaqus 6.13 to model both tests. Applying the simulations, an inverse parameter identification is run to determine the full set of cohesive parameters.

  1. Statistics of the work done on a quantum critical system by quenching a control parameter.

    PubMed

    Silva, Alessandro

    2008-09-19

    We study the statistics of the work done on a quantum critical system by quenching a control parameter in the Hamiltonian. We elucidate the relation between the probability distribution of the work and the Loschmidt echo, a quantity emerging usually in the context of dephasing. Using this connection we characterize the statistics of the work done on a quantum Ising chain by quenching locally or globally the transverse field. We show that for local quenches starting at criticality the probability distribution of the work displays an interesting edge singularity.

  2. Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea Test Experiments

    DTIC Science & Technology

    2017-01-19

    Naval Research Laboratory Washington, DC 20375-5320 NRL/MR/7160--17-9702 Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea ...LIMITATION OF ABSTRACT Low-Frequency Surface Backscattering Strengths Measured in the Critical Sea Test Experiments Roger C. Gauss1 and Joseph M...significantly- updated results from 55 broadband SUS SSS measurements in 6 Critical Sea Test (CST) experiments. Since the time of the previously

  3. Construction Of Critical Thinking Skills Test Instrument Related The Concept On Sound Wave

    NASA Astrophysics Data System (ADS)

    Mabruroh, F.; Suhandi, A.

    2017-02-01

    This study aimed to construct test instrument of critical thinking skills of high school students related the concept on sound wave. This research using a mixed methods with sequential exploratory design, consists of: 1) a preliminary study; 2) design and review of test instruments. The form of test instruments in essay questions, consist of 18 questions that was divided into 5 indicators and 8 sub-indicators of the critical thinking skills expressed by Ennis, with questions that are qualitative and contextual. Phases of preliminary study include: a) policy studies; b) survey to the school; c) and literature studies. Phases of the design and review of test instruments consist of two steps, namely a draft design of test instruments include: a) analysis of the depth of teaching materials; b) the selection of indicators and sub-indicators of critical thinking skills; c) analysis of indicators and sub-indicators of critical thinking skills; d) implementation of indicators and sub-indicators of critical thinking skills; and e) making the descriptions about the test instrument. In the next phase of the review test instruments, consist of: a) writing about the test instrument; b) validity test by experts; and c) revision of test instruments based on the validator.

  4. Validation of a New Small-Volume Sodium Citrate Collection Tube for Coagulation Testing in Critically Ill Patients with Coagulopathy.

    PubMed

    Adam, Elisabeth H; Zacharowski, Kai; Hintereder, Gudrun; Raimann, Florian; Meybohm, Patrick

    2018-06-01

    Blood loss due to phlebotomy leads to hospital-acquired anemia and more frequent blood transfusions that may be associated with increased risk of morbidity and mortality in critically ill patients. Multiple blood conservation strategies have been proposed in the context of patient blood management to minimize blood loss. Here, we evaluated a new small-volume sodium citrate collection tube for coagulation testing in critically ill patients. In 46 critically adult ill patients admitted to an interdisciplinary intensive care unit, we prospectively compared small-volume (1.8 mL) sodium citrate tubes with the conventional (3 mL) sodium citrate tubes. The main inclusion criterium was a proven coagulopathy (Quick < 60% and/or aPTT > 40 second) due to anticoagulation therapy or perioperative coagulopathy. In total, 92 coagulation analyses were obtained. Linear correlation analysis detected a positive relationship for 7 coagulation parameters (Prothrombin Time, r = 0.987; INR, r = 0.985; activated Partial Thromboplastin Time, r = 0.967; Thrombin Clotting Time, r = 0.969; Fibrinogen, r = 0.986; Antithrombin, r = 0.988; DDimer, r = 0.969). Bland-Altman analyses revealed an absolute mean of differences of almost zero. Ninety-five percent of data were within two standard deviations of the mean difference suggesting interchangeability. As systematic deviations between measured parameters of the two tubes were very unlikely, test results of small-volume (1.8 mL) sodium citrate tubes were equal to conventional (3 mL) sodium citrate tubes and can be considered interchangeable. Small-volume sodium citrate tubes reduced unnecessary diagnostic-related blood loss by about 40% and, therefore, should be the new standard of care for routine coagulation analysis in critically ill patients.

  5. 40 CFR 761.389 - Testing parameter requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... variable testing parameters described in this section which may be used in the validation study. The conditions demonstrated in the validation study for these variables shall become the required conditions for.... During the validation study, use the same ratio of contaminated surface area to soak solvent volume as...

  6. 40 CFR 761.389 - Testing parameter requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... variable testing parameters described in this section which may be used in the validation study. The conditions demonstrated in the validation study for these variables shall become the required conditions for.... During the validation study, use the same ratio of contaminated surface area to soak solvent volume as...

  7. 40 CFR 761.389 - Testing parameter requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... variable testing parameters described in this section which may be used in the validation study. The conditions demonstrated in the validation study for these variables shall become the required conditions for.... During the validation study, use the same ratio of contaminated surface area to soak solvent volume as...

  8. Incorporating Critical Thinking and Authenticity into Business German Testing.

    ERIC Educational Resources Information Center

    Egbert, Maria; Maxim, Hiram

    1998-01-01

    Proposes to integrate critical thinking and problem-solving into two existing international tests of business German (Prufung Wirtschaftsdeutsch International and Zertifikat Deutsch fur den Beruf), and to contextualize the tests' tasks in a more authentic business setting without compromising their content. Parallels are drawn with the American…

  9. Binary Colloidal Alloy Test-3 and 4: Critical Point

    NASA Technical Reports Server (NTRS)

    Weitz, David A.; Lu, Peter J.

    2007-01-01

    Binary Colloidal Alloy Test - 3 and 4: Critical Point (BCAT-3-4-CP) will determine phase separation rates and add needed points to the phase diagram of a model critical fluid system. Crewmembers photograph samples of polymer and colloidal particles (tiny nanoscale spheres suspended in liquid) that model liquid/gas phase changes. Results will help scientists develop fundamental physics concepts previously cloaked by the effects of gravity.

  10. Influence of Fallible Item Parameters on Test Information During Adaptive Testing.

    ERIC Educational Resources Information Center

    Wetzel, C. Douglas; McBride, James R.

    Computer simulation was used to assess the effects of item parameter estimation errors on different item selection strategies used in adaptive and conventional testing. To determine whether these effects reduced the advantages of certain optimal item selection strategies, simulations were repeated in the presence and absence of item parameter…

  11. Testing algorithms for critical slowing down

    NASA Astrophysics Data System (ADS)

    Cossu, Guido; Boyle, Peter; Christ, Norman; Jung, Chulwoo; Jüttner, Andreas; Sanfilippo, Francesco

    2018-03-01

    We present the preliminary tests on two modifications of the Hybrid Monte Carlo (HMC) algorithm. Both algorithms are designed to travel much farther in the Hamiltonian phase space for each trajectory and reduce the autocorrelations among physical observables thus tackling the critical slowing down towards the continuum limit. We present a comparison of costs of the new algorithms with the standard HMC evolution for pure gauge fields, studying the autocorrelation times for various quantities including the topological charge.

  12. Quality-by-design (QbD): effects of testing parameters and formulation variables on the segregation tendency of pharmaceutical powder measured by the ASTM D 6940-04 segregation tester.

    PubMed

    Xie, Lin; Wu, Huiquan; Shen, Meiyu; Augsburger, Larry L; Lyon, Robbe C; Khan, Mansoor A; Hussain, Ajaz S; Hoag, Stephen W

    2008-10-01

    The objective of this study was to examine the effects of testing parameters and formulation variables on the segregation tendency of pharmaceutical powders measured by the ASTM D 6940-04 segregation tester using design of experiments (DOE) approaches. The test blends consisted of 4% aspirin (ASP) and 96% microcrystalline cellulose (MCC) with and without magnesium stearate (MgS). The segregation tendency of a blend was determined by measuring the last/first (L/F) ratio, the ratio of aspirin concentrations between the first and last samples discharged from the tester. A 2(2) factorial design was used to determine the effects of measurement parameters [amount of material loaded (W), number of segregation cycles] with number of replicates 6. ANOVA showed that W was a critical parameter for segregation testing. The L/F value deviated further from 1 (greater segregation tendency) with increasing W. A 2(3) full factorial design was used to assess the effects of formulation variables: grade of ASP (unmilled, milled), grade of MCC, and amount of lubricant, MgS. MLR and ANOVA showed that the grade of ASP was the main effect contributing to segregation tendency. Principal Component Regression Analysis established a correlation between L/F and the physical properties of the blend related to ASP and MCC, the ASP/MCC particle size ratio (PSR) and powder cohesion. The physical properties of the blend related to density and flow were not influenced by the grade of ASP and were not related to the segregation tendency of the blend. The direct relationship between L/F and PSR was determined by univariate analysis. Segregation tendency increased as the ASP to MCC particle size increased. This study highlighted critical test parameters for segregation testing and identified critical physical properties of the blends that influence segregation tendency. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association

  13. Testing Saliency Parameters for Automatic Target Recognition

    NASA Technical Reports Server (NTRS)

    Pandya, Sagar

    2012-01-01

    A bottom-up visual attention model (the saliency model) is tested to enhance the performance of Automated Target Recognition (ATR). JPL has developed an ATR system that identifies regions of interest (ROI) using a trained OT-MACH filter, and then classifies potential targets as true- or false-positives using machine-learning techniques. In this project, saliency is used as a pre-processing step to reduce the space for performing OT-MACH filtering. Saliency parameters, such as output level and orientation weight, are tuned to detect known target features. Preliminary results are promising and future work entails a rigrous and parameter-based search to gain maximum insight about this method.

  14. The California Critical Thinking Skills Test and Business School Performance

    ERIC Educational Resources Information Center

    Bycio, Peter; Allen, Joyce S.

    2009-01-01

    An intent of many business programs is to enhance the critical thinking capabilities of their students. Since AACSB accreditation requires evidence that business schools fulfill their goals, our students were required to take the California Critical Thinking Skills Test (CCTST). As expected, the CCTST was significantly related to SAT performance…

  15. Test Design and Speededness

    ERIC Educational Resources Information Center

    van der Linden, Wim J.

    2011-01-01

    A critical component of test speededness is the distribution of the test taker's total time on the test. A simple set of constraints on the item parameters in the lognormal model for response times is derived that can be used to control the distribution when assembling a new test form. As the constraints are linear in the item parameters, they can…

  16. Critical laboratory values in hemostasis: toward consensus.

    PubMed

    Lippi, Giuseppe; Adcock, Dorothy; Simundic, Ana-Maria; Tripodi, Armando; Favaloro, Emmanuel J

    2017-09-01

    The term "critical values" can be defined to entail laboratory test results that significantly lie outside the normal (reference) range and necessitate immediate reporting to safeguard patient health, as well as those displaying a highly and clinically significant variation compared to previous data. The identification and effective communication of "highly pathological" values has engaged the minds of many clinicians, health care and laboratory professionals for decades, since these activities are vital to good laboratory practice. This is especially true in hemostasis, where a timely and efficient communication of critical values strongly impacts patient management. Due to the heterogeneity of available data, this paper is hence aimed to analyze the state of the art and provide an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis, thus providing a basic document for future consultation that assists laboratory professionals and clinicians alike. KEY MESSAGES Critical values are laboratory test results significantly lying outside the normal (reference) range and necessitating immediate reporting to safeguard patient health. A broad heterogeneity exists about critical values in hemostasis worldwide. We provide here an expert opinion about the parameters, measurement units and alert limits pertaining to critical values in hemostasis.

  17. Fabrication, test and demonstration of critical environment monitoring system

    NASA Technical Reports Server (NTRS)

    Heimendinger, K. W.

    1972-01-01

    Design and performance of an analytical system for the evaluation of certain environmental constituents in critical environmental areas of the Quality Reliability and Assurance Laboratory are reported. Developed was a self-contained, integrated, minimum sized unit that detects, interrogates, and records those parameters of the environment dictated for control in large storage facilities, clean rooms, temporarily curtained enclosures, and special working benches. The system analyzes humidity, temperature, hydrocarbons particle size, and particle count within prescribed clean areas.

  18. Time and Performance on the California Critical Thinking Skills Test.

    ERIC Educational Resources Information Center

    Frisby, Craig L.; Traffanstedt, Bobby K.

    2003-01-01

    Investigates the relationship between total scores on the California Critical Thinking Skills Test (CCTST) and the time taken to complete it. Finds that slower test takers obtained significantly higher scores. Discusses implications of these findings for college instruction. (SG)

  19. The Role of the Cooling Prescription for Disk Fragmentation: Numerical Convergence and Critical Cooling Parameter in Self-gravitating Disks

    NASA Astrophysics Data System (ADS)

    Baehr, Hans; Klahr, Hubert

    2015-12-01

    Protoplanetary disks fragment due to gravitational instability when there is enough mass for self-gravitation, described by the Toomre parameter, and when heat can be lost at a rate comparable to the local dynamical timescale, described by {t}{{c}}=β {{{Ω }}}-1. Simulations of self-gravitating disks show that the cooling parameter has a rough critical value at {β }{{crit}}=3. When below {β }{{crit}}, gas overdensities will contract under their own gravity and fragment into bound objects while otherwise maintaining a steady state of gravitoturbulence. However, previous studies of the critical cooling parameter have found dependences on simulation resolution, indicating that the simulation of self-gravitating protoplanetary disks is not so straightforward. In particular, the simplicity of the cooling timescale tc prevents fragments from being disrupted by pressure support as temperatures rise. We alter the cooling law so that the cooling timescale is dependent on local surface density fluctuations, which is a means of incorporating optical depth effects into the local cooling of an object. For lower resolution simulations, this results in a lower critical cooling parameter and a disk that is more stable to gravitational stresses, suggesting that the formation of large gas giants planets in large, cool disks is generally suppressed by more realistic cooling. At our highest resolution, however, the model becomes unstable to fragmentation for cooling timescales up to β =10.

  20. Virtual test: A student-centered software to measure student's critical thinking on human disease

    NASA Astrophysics Data System (ADS)

    Rusyati, Lilit; Firman, Harry

    2016-02-01

    The study "Virtual Test: A Student-Centered Software to Measure Student's Critical Thinking on Human Disease" is descriptive research. The background is importance of computer-based test that use element and sub element of critical thinking. Aim of this study is development of multiple choices to measure critical thinking that made by student-centered software. Instruments to collect data are (1) construct validity sheet by expert judge (lecturer and medical doctor) and professional judge (science teacher); and (2) test legibility sheet by science teacher and junior high school student. Participants consisted of science teacher, lecturer, and medical doctor as validator; and the students as respondent. Result of this study are describe about characteristic of virtual test that use to measure student's critical thinking on human disease, analyze result of legibility test by students and science teachers, analyze result of expert judgment by science teachers and medical doctor, and analyze result of trial test of virtual test at junior high school. Generally, result analysis shown characteristic of multiple choices to measure critical thinking was made by eight elements and 26 sub elements that developed by Inch et al.; complete by relevant information; and have validity and reliability more than "enough". Furthermore, specific characteristic of multiple choices to measure critical thinking are information in form science comic, table, figure, article, and video; correct structure of language; add source of citation; and question can guide student to critical thinking logically.

  1. A means to estimate thermal and kinetic parameters of coal dust layer from hot surface ignition tests.

    PubMed

    Park, Haejun; Rangwala, Ali S; Dembsey, Nicholas A

    2009-08-30

    A method to estimate thermal and kinetic parameters of Pittsburgh seam coal subject to thermal runaway is presented using the standard ASTM E 2021 hot surface ignition test apparatus. Parameters include thermal conductivity (k), activation energy (E), coupled term (QA) of heat of reaction (Q) and pre-exponential factor (A) which are required, but rarely known input values to determine the thermal runaway propensity of a dust material. Four different dust layer thicknesses: 6.4, 12.7, 19.1 and 25.4mm, are tested, and among them, a single steady state dust layer temperature profile of 12.7 mm thick dust layer is used to estimate k, E and QA. k is calculated by equating heat flux from the hot surface layer and heat loss rate on the boundary assuming negligible heat generation in the coal dust layer at a low hot surface temperature. E and QA are calculated by optimizing a numerically estimated steady state dust layer temperature distribution to the experimentally obtained temperature profile of a 12.7 mm thick dust layer. Two unknowns, E and QA, are reduced to one from the correlation of E and QA obtained at criticality of thermal runaway. The estimated k is 0.1 W/mK matching the previously reported value. E ranges from 61.7 to 83.1 kJ/mol, and the corresponding QA ranges from 1.7 x 10(9) to 4.8 x 10(11)J/kg s. The mean values of E (72.4 kJ/mol) and QA (2.8 x 10(10)J/kg s) are used to predict the critical hot surface temperatures for other thicknesses, and good agreement is observed between measured and experimental values. Also, the estimated E and QA ranges match the corresponding ranges calculated from the multiple tests method and values reported in previous research.

  2. A Stepwise Test Characteristic Curve Method to Detect Item Parameter Drift

    ERIC Educational Resources Information Center

    Guo, Rui; Zheng, Yi; Chang, Hua-Hua

    2015-01-01

    An important assumption of item response theory is item parameter invariance. Sometimes, however, item parameters are not invariant across different test administrations due to factors other than sampling error; this phenomenon is termed item parameter drift. Several methods have been developed to detect drifted items. However, most of the…

  3. The assessment of body sway and the choice of the stability parameter(s).

    PubMed

    Raymakers, J A; Samson, M M; Verhaar, H J J

    2005-01-01

    This methodological study aims at comparison of the practical usefulness of several parameters of body sway derived from recordings of the center of pressure (CoP) with the aid of a static force platform as proposed in the literature. These included: mean displacement velocity, maximal range of movement along x- and y-co-ordinates, movement area, planar deviation, phase plane parameter of Riley and the parameters of the diffusion stabilogram according to Collins. They were compared in over 850 experiments in a group of young healthy subjects (n = 10, age 21-45 years), a group of elderly healthy (n = 38, age 61-78 years) and two groups of elderly subjects (n = 10 and n = 21, age 65-89 years) with stability problems under different conditions known to interfere with stability as compared to standing with open eyes fixing a visual anchoring point: closing the eyes, standing on plastic foam in stead of a firm surface and performing a cognitive task: the modified stroop test. A force platform (Kistler) was used and co-ordinates of the body's center of pressure were recorded during 60 s of quiet barefoot standing with a sampling frequency of 10 Hz. In general, the results show important overlapping among groups and test conditions. Mean displacement velocity shows the most consistent differences between test situations, health conditions and age ranges, but is not affected by an extra cognitive task in healthy old people. Mean maximal sideways sway range is different among groups and test conditions except for the cognitive task in young and elderly subjects. Standardised displacement parameters such as standard deviations of displacements and planar deviation discriminate less well than the actual range of motion or the velocity. The critical time interval derived from the diffusion stabilogram according to Collins et al. seems to add a specific type of information since it shows significant influence from addition of a cognitive task in old subjects standing on a firm

  4. A primer on criticality safety

    DOE PAGES

    Costa, David A.; Cournoyer, Michael E.; Merhege, James F.; ...

    2017-05-01

    Criticality is the state of a nuclear chain reacting medium when the chain reaction is just self-sustaining (or critical). Criticality is dependent on nine interrelated parameters. Moreover, we design criticality safety controls in order to constrain these parameters to minimize fissions and maximize neutron leakage and absorption in other materials, which makes criticality more difficult or impossible to achieve. We present the consequences of criticality accidents are discussed, the nine interrelated parameters that combine to affect criticality are described, and criticality safety controls used to minimize the likelihood of a criticality accident are presented.

  5. Critical physiological factors influencing the outcome of antimicrobial testing according to ISO 22196 / JIS Z 2801.

    PubMed

    Wiegand, Cornelia; Völpel, Andrea; Ewald, Andrea; Remesch, Markko; Kuever, Jan; Bauer, Janine; Griesheim, Stefanie; Hauser, Carolin; Thielmann, Julian; Tonndorf-Martini, Silke; Sigusch, Bernd W; Weisser, Jürgen; Wyrwa, Ralf; Elsner, Peter; Hipler, Uta-Christina; Roth, Martin; Dewald, Carolin; Lüdecke-Beyer, Claudia; Bossert, Jörg

    2018-01-01

    Bactericidal materials gained interest in the health care sector as they are capable of preventing material surfaces from microbial colonization and subsequent spread of infections. However, commercialization of antimicrobial materials requires proof of their efficacy, which is usually done using in vitro methods. The ISO 22196 standard (Japanese test method JIS Z 2801) is a method for measuring the antibacterial activity of daily goods. As it was found reliable for testing the biocidal activity of antimicrobially active materials and surface coatings most of the laboratories participating in this study used this protocol. Therefore, a round robin test for evaluating antimicrobially active biomaterials had to be established. To our knowledge, this is the first report on inaugurating a round robin test for the ISO 22196 / JIS Z 2801. The first round of testing showed that analyses in the different laboratories yielded different results, especially for materials with intermediate antibacterial effects distinctly different efficacies were noted. Scrutinizing the protocols used by the different participants and identifying the factors influencing the test outcomes the approach was unified. Four critical factors influencing the outcome of antibacterial testing were identified in a series of experiments: (1) incubation time, (2) bacteria starting concentration, (3) physiological state of bacteria (stationary or exponential phase of growth), and (4) nutrient concentration. To our knowledge, this is the first time these parameters have been analyzed for their effect on the outcome of testing according to ISO 22196 / JIS Z 2801. In conclusion, to enable assessment of the results obtained it is necessary to evaluate these single parameters in the test protocol carefully. Furthermore, uniform and robust definitions of the terms antibacterial efficacy / activity, bacteriostatic effects, and bactericidal action need to be agreed upon to simplify communication of results and

  6. Critical physiological factors influencing the outcome of antimicrobial testing according to ISO 22196 / JIS Z 2801

    PubMed Central

    Völpel, Andrea; Ewald, Andrea; Remesch, Markko; Kuever, Jan; Bauer, Janine; Griesheim, Stefanie; Hauser, Carolin; Thielmann, Julian; Tonndorf-Martini, Silke; Sigusch, Bernd W.; Weisser, Jürgen; Wyrwa, Ralf; Elsner, Peter; Hipler, Uta-Christina; Roth, Martin; Dewald, Carolin; Lüdecke-Beyer, Claudia; Bossert, Jörg

    2018-01-01

    Bactericidal materials gained interest in the health care sector as they are capable of preventing material surfaces from microbial colonization and subsequent spread of infections. However, commercialization of antimicrobial materials requires proof of their efficacy, which is usually done using in vitro methods. The ISO 22196 standard (Japanese test method JIS Z 2801) is a method for measuring the antibacterial activity of daily goods. As it was found reliable for testing the biocidal activity of antimicrobially active materials and surface coatings most of the laboratories participating in this study used this protocol. Therefore, a round robin test for evaluating antimicrobially active biomaterials had to be established. To our knowledge, this is the first report on inaugurating a round robin test for the ISO 22196 / JIS Z 2801. The first round of testing showed that analyses in the different laboratories yielded different results, especially for materials with intermediate antibacterial effects distinctly different efficacies were noted. Scrutinizing the protocols used by the different participants and identifying the factors influencing the test outcomes the approach was unified. Four critical factors influencing the outcome of antibacterial testing were identified in a series of experiments: (1) incubation time, (2) bacteria starting concentration, (3) physiological state of bacteria (stationary or exponential phase of growth), and (4) nutrient concentration. To our knowledge, this is the first time these parameters have been analyzed for their effect on the outcome of testing according to ISO 22196 / JIS Z 2801. In conclusion, to enable assessment of the results obtained it is necessary to evaluate these single parameters in the test protocol carefully. Furthermore, uniform and robust definitions of the terms antibacterial efficacy / activity, bacteriostatic effects, and bactericidal action need to be agreed upon to simplify communication of results and

  7. Testing new methodologies for short -term earthquake forecasting: Multi-parameters precursors

    NASA Astrophysics Data System (ADS)

    Ouzounov, Dimitar; Pulinets, Sergey; Tramutoli, Valerio; Lee, Lou; Liu, Tiger; Hattori, Katsumi; Kafatos, Menas

    2014-05-01

    We are conducting real-time tests involving multi-parameter observations over different seismo-tectonics regions in our investigation of phenomena preceding major earthquakes. Our approach is based on a systematic analysis of several selected parameters, namely: gas discharge; thermal infrared radiation; ionospheric electron density; and atmospheric temperature and humidity, which we believe are all associated with the earthquake preparation phase. We are testing a methodology capable to produce alerts in advance of major earthquakes (M > 5.5) in different regions of active earthquakes and volcanoes. During 2012-2013 we established a collaborative framework with PRE-EARTHQUAKE (EU) and iSTEP3 (Taiwan) projects for coordinated measurements and prospective validation over seven testing regions: Southern California (USA), Eastern Honshu (Japan), Italy, Greece, Turkey, Taiwan (ROC), Kamchatka and Sakhalin (Russia). The current experiment provided a "stress test" opportunity to validate the physical based earthquake precursor approach over regions of high seismicity. Our initial results are: (1) Real-time tests have shown the presence of anomalies in the atmosphere and ionosphere before most of the significant (M>5.5) earthquakes; (2) False positives exist and ratios are different for each region, varying between 50% for (Southern Italy), 35% (California) down to 25% (Taiwan, Kamchatka and Japan) with a significant reduction of false positives as soon as at least two geophysical parameters are contemporarily used; (3) Main problems remain related to the systematic collection and real-time integration of pre-earthquake observations. Our findings suggest that real-time testing of physically based pre-earthquake signals provides a short-term predictive power (in all three important parameters, namely location, time and magnitude) for the occurrence of major earthquakes in the tested regions and this result encourages testing to continue with a more detailed analysis of

  8. A new qualitative acoustic emission parameter based on Shannon's entropy for damage monitoring

    NASA Astrophysics Data System (ADS)

    Chai, Mengyu; Zhang, Zaoxiao; Duan, Quan

    2018-02-01

    An important objective of acoustic emission (AE) non-destructive monitoring is to accurately identify approaching critical damage and to avoid premature failure by means of the evolutions of AE parameters. One major drawback of most parameters such as count and rise time is that they are strongly dependent on the threshold and other settings employed in AE data acquisition system. This may hinder the correct reflection of original waveform generated from AE sources and consequently bring difficulty for the accurate identification of the critical damage and early failure. In this investigation, a new qualitative AE parameter based on Shannon's entropy, i.e. AE entropy is proposed for damage monitoring. Since it derives from the uncertainty of amplitude distribution of each AE waveform, it is independent of the threshold and other time-driven parameters and can characterize the original micro-structural deformations. Fatigue crack growth test on CrMoV steel and three point bending test on a ductile material are conducted to validate the feasibility and effectiveness of the proposed parameter. The results show that the new parameter, compared to AE amplitude, is more effective in discriminating the different damage stages and identifying the critical damage.

  9. Predicting Critical Power in Elite Cyclists: Questioning the Validity of the 3-Minute All-Out Test.

    PubMed

    Bartram, Jason C; Thewlis, Dominic; Martin, David T; Norton, Kevin I

    2017-07-01

    New applications of the critical-power concept, such as the modeling of intermittent-work capabilities, are exciting prospects for elite cycling. However, accurate calculation of the required parameters is traditionally time invasive and somewhat impractical. An alternative single-test protocol (3-min all-out) has recently been proposed, but validation in an elite population is lacking. The traditional approach for parameter establishment, but with fewer tests, could also prove an acceptable compromise. Six senior Australian endurance track-cycling representatives completed 6 efforts to exhaustion on 2 separate days over a 3-wk period. These included 1-, 4-, 6-, 8-, and 10-min self-paced efforts, plus the 3-min all-out protocol. Traditional work-vs-time calculations of CP and anaerobic energy contribution (W') using the 5 self-paced efforts were compared with calculations from the 3-min all-out protocol. The impact of using just 2 or 3 self-paced efforts for traditional CP and W' estimation was also explored using thresholds of agreement (8 W, 2.0 kJ, respectively). CP estimated from the 3-min all-out approach was significantly higher than from the traditional approach (402 ± 33, 351 ± 27 W, P < .001), while W' was lower (15.5 ± 3.0, 24.3 ± 4.0 kJ, P = .02). Five different combinations of 2 or 3 self-paced efforts led to CP estimates within the threshold of agreement, with only 1 combination deemed accurate for W'. In elite cyclists the 3-min all-out approach is not suitable to estimate CP when compared with the traditional method. However, reducing the number of tests used in the traditional method lessens testing burden while maintaining appropriate parameter accuracy.

  10. Utility of repeat testing of critical values: a Q-probes analysis of 86 clinical laboratories.

    PubMed

    Lehman, Christopher M; Howanitz, Peter J; Souers, Rhona; Karcher, Donald S

    2014-06-01

    A common laboratory practice is to repeat critical values before reporting the test results to the clinical care provider. This may be an unnecessary step that delays the reporting of critical test results without adding value to the accuracy of the test result. To determine the proportions of repeated chemistry and hematology critical values that differ significantly from the original value as defined by the participating laboratory, to determine the threshold differences defined by the laboratory as clinically significant, and to determine the additional time required to analyze the repeat test. Participants prospectively reviewed critical test results for 4 laboratory tests: glucose, potassium, white blood cell count, and platelet count. Participants reported the following information: initial and repeated test result; time initial and repeat results were first known to laboratory staff; critical result notification time; if the repeat result was still a critical result; if the repeat result was significantly different from the initial result, as judged by the laboratory professional or policy; significant difference threshold, as defined by the laboratory; the make and model of the instrument used for primary and repeat testing. Routine, repeat analysis of critical values is a common practice. Most laboratories did not formally define a significant difference between repeat results. Repeated results were rarely considered significantly different. Median repeated times were at least 17 to 21 minutes for 10% of laboratories. Twenty percent of laboratories reported at least 1 incident in the last calendar year of delayed result reporting that clinicians indicated had adversely affected patient care. Routine repeat analysis of automated chemistry and hematology critical values is unlikely to be clinically useful and may adversely affect patient care.

  11. Critical thinking evaluation in reflective writing: Development and testing of Carter Assessment of Critical Thinking in Midwifery (Reflection).

    PubMed

    Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary

    2017-11-01

    develop and test a tool designed for use by academics to evaluate pre-registration midwifery students' critical thinking skills in reflective writing. a descriptive cohort design was used. a random sample (n = 100) of archived student reflective writings based on a clinical event or experience during 2014 and 2015. a staged model for tool development was used to develop a fifteen item scale involving item generation; mapping of draft items to critical thinking concepts and expert review to test content validity; inter-rater reliability testing; pilot testing of the tool on 100 reflective writings; and psychometric testing. Item scores were analysed for mean, range and standard deviation. Internal reliability, content and construct validity were assessed. expert review of the tool revealed a high content validity index score of 0.98. Using two independent raters to establish inter-rater reliability, good absolute agreement of 72% was achieved with a Kappa coefficient K = 0.43 (p<0.0001). Construct validity via exploratory factor analysis revealed three factors: analyses context, reasoned inquiry, and self-evaluation. The mean total score for the tool was 50.48 (SD = 12.86). Total and subscale scores correlated significantly. The scale achieved good internal reliability with a Cronbach's alpha coefficient of .93. this study establishedthe reliability and validity of the CACTiM (reflection) for use by academics to evaluate midwifery students' critical thinking in reflective writing. Validation with large diverse samples is warranted. reflective practice is a key learning and teaching strategy in undergraduate Bachelor of Midwifery programmes and essential for safe, competent practice. There is the potential to enhance critical thinking development by assessingreflective writing with the CACTiM (reflection) tool to provide formative and summative feedback to students and inform teaching strategies. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  12. Measurement of the Critical Distance Parameter Against Icing Conditions on a NACA 0012 Swept Wing Tip

    NASA Technical Reports Server (NTRS)

    Vargas, Mario; Kreeger, Richard E.

    2011-01-01

    This work presents the results of three experiments, one conducted in the Icing Research Tunnel (IRT) at NASA Glenn Research Center and two in the Goodrich Icing Wind Tunnel (IWT). The experiments were designed to measure the critical distance parameter on a NACA 0012 Swept Wing Tip at sweep angles of 45deg, 30deg, and 15deg. A time sequence imaging technique (TSIT) was used to obtain real time close-up imaging data during the first 2 min of the ice accretion formation. The time sequence photographic data was used to measure the critical distance at each icing condition and to study how it develops in real time. The effect on the critical distance of liquid water content, drop size, total temperature, and velocity was studied. The results were interpreted using a simple energy balance on a roughness element

  13. Ten Issues in Criterion-Referenced Testing: A Response to Commonly Heard Criticisms.

    ERIC Educational Resources Information Center

    Curlette, William L.; Stallings, William M.

    1979-01-01

    The 10 criticisms of criterion-referenced tests addressed in this paper are: the domains tested; pedagogical influence; difficulty of items; cumbersome reports; reliability; arbitrary criteria; local objectives; labeling; predictive validity; and repeated testing. (SJL)

  14. Development of a New Critical Thinking Test Using Item Response Theory

    ERIC Educational Resources Information Center

    Wagner, Teresa A.; Harvey, Robert J.

    2006-01-01

    The authors describe the initial development of the Wagner Assessment Test (WAT), an instrument designed to assess critical thinking, using the 5-faceted view popularized by the Watson-Glaser Critical Thinking Appraisal (WGCTA; G. B. Watson & E. M. Glaser, 1980). The WAT was designed to reduce the degree of successful guessing relative to the…

  15. Validation of Sherouk's Critical Thinking Test (SH-CTT)

    ERIC Educational Resources Information Center

    Kadhm, Sherouk J.

    2017-01-01

    This study aimed to examine the psychometric properties (reliability and validity) of the Arabic version of Sherouk's Critical Thinking Test. This test has four parts, each of which provides a story that is divided into an introduction and a scene; each story is then followed by a list of sensitive questions featuring two response options…

  16. A Normalized Direct Approach for Estimating the Parameters of the Normal Ogive Three-Parameter Model for Ability Tests.

    ERIC Educational Resources Information Center

    Gugel, John F.

    A new method for estimating the parameters of the normal ogive three-parameter model for multiple-choice test items--the normalized direct (NDIR) procedure--is examined. The procedure is compared to a more commonly used estimation procedure, Lord's LOGIST, using computer simulations. The NDIR procedure uses the normalized (mid-percentile)…

  17. A Testing Framework for Critical Space SW

    NASA Astrophysics Data System (ADS)

    Fernandez, Ignacio; Di Cerbo, Antonio; Dehnhardt, Erik; Massimo, Tipaldi; Brünjes, Bernhard

    2015-09-01

    This paper describes a testing framework for critical space SW named Technical Specification Validation Framework (TSVF). It provides a powerful and flexible means and can be used throughout the SW test activities (test case specification & implementation, test execution and test artifacts analysis). In particular, tests can be run in an automated and/or step-by-step mode. The TSVF framework is currently used for the validation of the Satellite Control Software (SCSW), which runs on the Meteosat Third Generation (MTG) satellite on-board computer. The main purpose of the SCSW is to control the spacecraft along with its various subsystems (AOCS, Payload, Electrical Power, Telemetry Tracking & Command, etc.) in a way that guarantees a high degree of flexibility and autonomy. The TSVF framework serves the challenging needs of the SCSW project, where a plan-driven approach has been combined with an agile process in order to produce preliminary SW versions (with a reduced scope of implemented functionality) in order to fulfill the stakeholders needs ([1]). The paper has been organised as follows. Section 2 gives an overview of the TSVF architecture and interfaces versus the test bench along with the technology used for its implementation. Section 3 describes the key elements of the XML based language for the test case implementation. Section 4 highlights all the benefits compared to conventional test environments requiring a manual test script development, whereas section 5 concludes the paper.

  18. Collaborative testing: assessing teamwork and critical thinking behaviors in baccalaureate nursing students.

    PubMed

    Wiggs, Carol M

    2011-04-01

    The purpose of this study was to foster teamwork and critical thinking behaviors in baccalaureate nursing students using a collaborative testing environment. Collaborative testing affords the nurse educator a unique opportunity to actively influence the development of critical thinking skills directly influencing the nursing student's ability to solve complex patient problems. Using a quasi-experimental approach exam scores from students in prior semesters were compared to students in several semesters using collaborative testing in one undergraduate course taught by the same faculty. In the experimental group collaborative testing was used in the two unit examinations, while the final examination remained individual. For collaborative testing the students were grouped by random assignment. They were not allowed the use of notes, textbooks, or other resource materials. Any student who wished to work alone was allowed do so and any student coming late (within 15 min of examination beginning) was required to work alone. Each student submitted individual examination answer forms, and groups were not required to reach consensus. Collaborative testing is one means to foster critical thinking by allowing students to solve complex patient problems within an examination environment. This better prepares them for national certification exams. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Identification of groundwater flow parameters using reciprocal data from hydraulic interference tests

    NASA Astrophysics Data System (ADS)

    Marinoni, Marianna; Delay, Frederick; Ackerer, Philippe; Riva, Monica; Guadagnini, Alberto

    2016-08-01

    We investigate the effect of considering reciprocal drawdown curves for the characterization of hydraulic properties of aquifer systems through inverse modeling based on interference well testing. Reciprocity implies that drawdown observed in a well B when pumping takes place from well A should strictly coincide with the drawdown observed in A when pumping in B with the same flow rate as in A. In this context, a critical point related to applications of hydraulic tomography is the assessment of the number of available independent drawdown data and their impact on the solution of the inverse problem. The issue arises when inverse modeling relies upon mathematical formulations of the classical single-continuum approach to flow in porous media grounded on Darcy's law. In these cases, introducing reciprocal drawdown curves in the database of an inverse problem is equivalent to duplicate some information, to a certain extent. We present a theoretical analysis of the way a Least-Square objective function and a Levenberg-Marquardt minimization algorithm are affected by the introduction of reciprocal information in the inverse problem. We also investigate the way these reciprocal data, eventually corrupted by measurement errors, influence model parameter identification in terms of: (a) the convergence of the inverse model, (b) the optimal values of parameter estimates, and (c) the associated estimation uncertainty. Our theoretical findings are exemplified through a suite of computational examples focused on block-heterogeneous systems with increased complexity level. We find that the introduction of noisy reciprocal information in the objective function of the inverse problem has a very limited influence on the optimal parameter estimates. Convergence of the inverse problem improves when adding diverse (nonreciprocal) drawdown series, but does not improve when reciprocal information is added to condition the flow model. The uncertainty on optimal parameter estimates is

  20. Influence of selected test parameters on measured values during the MSCR test

    NASA Astrophysics Data System (ADS)

    Benešová, Lucie; Valentin, Jan

    2017-09-01

    One of today’s most commonly used test on a Dynamic Shear Rheometer (DSR) is the Multiple Stress Creep Recovery (MSCR) test. The test is described in the standard EN 16659, which is valid in the Czech Republic since October 2016. The principle of the test is based on repeated loading and recovering of a bitumen sample, according to which it is possible to determine the percentage of elastic recovery (R) and non-recoverable creep compliance (Jnr) of the bituminous binder. This method has been recently promoted as the most suitable test for assessing the resistance of bituminous binders to permanent deformation. The test is performed at higher temperatures and is particularly suitable for modified bituminous binders. The paper deals with the comparison of the different input parameters set on the DSR device - different levels of stress, temperature of test, the geometry of the measuring device and also a comparison of the results for a different number of loading cycles. The research study was focused mainly on modified bituminous binders, but to compare the MSCR test it is performed even with conventional paving grade binders.

  1. Using simulation to test critical thinking skills of nursing students.

    PubMed

    Johannsson, S L; Wertenberger, D H

    1996-10-01

    The purpose of this pilot study was to evaluate the effectiveness of using simulations to test critical thinking ability of nursing students. Nine medical and surgical videotaped vignettes were selected from the critical thinking component of the Performance Based Development System (PBDS). Pathology, difficulty rating and the obviousness of cues varied between vignettes. Each student was rated as acceptable, partially acceptable or unacceptable in their ability to identify a problem and provide appropriate nursing interventions with rationale for each vignette. A paper and pencil exercise and interviews were used to validate findings obtained from the video simulations. The pros and cons of using video simulations to assess critical thinking abilities of nursing students are discussed.

  2. Reading Results: A Critical Look at Standardized Testing and the Linguistic Minority

    ERIC Educational Resources Information Center

    Shannon, Joanie

    2008-01-01

    A critical look into assessing the Standardized Test and Reporting (STAR) test data among English language learners gives educators a chance to examine the cultural biases present within the standardized test movement started by the No Child Left Behind Act of 2001. In particular, The STAR test results seem to reflect that the test is geared…

  3. Identifying critical road geometry parameters affecting crash rate and crash type.

    PubMed

    Othman, Sarbaz; Thomson, Robert; Lannér, Gunnar

    2009-10-01

    The objective of this traffic safety investigation was to find critical road parameters affecting crash rate (CR). The study was based on crash and road maintenance data from Western Sweden. More than 3000 crashes, reported from 2000 to 2005 on median-separated roads, were collected and combined with road geometric and surface data. The statistical analysis showed variations in CR when road elements changed confirming that road characteristics affect CR. The findings indicated that large radii right-turn curves were more dangerous than left curves, in particular, during lane changing manoeuvres. However sharper curves are more dangerous in both left and right curves. Moreover, motorway carriageways with no or limited shoulders have the highest CR when compared to other carriageway widths, while one lane carriageway sections on 2+1 roads were the safest. Road surface results showed that both wheel rut depth and road roughness have negative impacts on traffic safety.

  4. Measuring Gains in Critical Thinking in Food Science and Human Nutrition Courses: The Cornell Critical Thinking Test, Problem-Based Learning Activities, and Student Journal Entries

    ERIC Educational Resources Information Center

    Iwaoka, Wayne T.; Li, Yong; Rhee, Walter Y.

    2010-01-01

    The Cornell Critical Thinking Test (CCTT) is one of the many multiple-choice tests with validated questions that have been reported to measure general critical thinking (CT) ability. One of the IFT Education Standards for undergraduate degrees in Food Science is the emphasis on the development of critical thinking. While this skill is easy to list…

  5. Static posturography with dynamic tests. Usefulness of biomechanical parameters in assessing vestibular patients.

    PubMed

    Balaguer García, Ramón; Pitarch Corresa, Salvador; Baydal Bertomeu, José María; Morales Suárez-Varela, María M

    2012-01-01

    Posturography allows evaluating postural control. This study showed the posturographic parameters that were useful for assessing the functional ability to maintain balance in our sample of vestibular patients. Of a total of 89 patients, 59 were healthy subjects and 30 had a peripheral vestibular disorder. The subjects were studied using the posturographic NedSVE/IBV system, combining static (Romberg) and dynamic (stability limits and rhythmic weight shifts) tests. We then compared the measurements found in the groups. Normal subjects showed significantly lower oscillations than our patients in all of the posturographic parameters studied (except the displacement angle). In testing the limits of stability, although normal subjects achieved maximum displacements greater than the subjects with the disorder, the differences found were not significant. In rhythmic weight shift tests, normal subjects showed more favourable results than did the vestibular patients, with significant differences in 3 of the 4 parameters studied: 1) anteroposterior ability, 2) mediolateral ability, and 3) anteroposterior control and efficiency. Rhythmic weight shift tests and the static posturography test parameters used were useful in discriminating among the normal and pathological subjects in this study. Copyright © 2011 Elsevier España, S.L. All rights reserved.

  6. The impact of repeat-testing of common chemistry analytes at critical concentrations.

    PubMed

    Onyenekwu, Chinelo P; Hudson, Careen L; Zemlin, Annalise E; Erasmus, Rajiv T

    2014-12-01

    Early notification of critical values by the clinical laboratory to the treating physician is a requirement for accreditation and is essential for effective patient management. Many laboratories automatically repeat a critical value before reporting it to prevent possible misdiagnosis. Given today's advanced instrumentation and quality assurance practices, we questioned the validity of this approach. We performed an audit of repeat-testing in our laboratory to assess for significant differences between initial and repeated test results, estimate the delay caused by repeat-testing and to quantify the cost of repeating these assays. A retrospective audit of repeat-tests for sodium, potassium, calcium and magnesium in the first quarter of 2013 at Tygerberg Academic Laboratory was conducted. Data on the initial and repeat-test values and the time that they were performed was extracted from our laboratory information system. The Clinical Laboratory Improvement Amendment criteria for allowable error were employed to assess for significant difference between results. A total of 2308 repeated tests were studied. There was no significant difference in 2291 (99.3%) of the samples. The average delay ranged from 35 min for magnesium to 42 min for sodium and calcium. At least 2.9% of laboratory running costs for the analytes was spent on repeating them. The practice of repeating a critical test result appears unnecessary as it yields similar results, delays notification to the treating clinician and increases laboratory running costs.

  7. Aerial View: SLS Intertank Arrives at Marshall for Critical Structural Testing

    NASA Image and Video Library

    2018-03-08

    A structural test version of the intertank for NASA's new deep-space rocket, the Space Launch System, arrives at NASA’s Marshall Space Flight Center in Huntsville, Alabama, March 4, aboard the barge Pegasus. The intertank is the second piece of structural hardware for the massive SLS core stage built at NASA's Michoud Assembly Facility in New Orleans delivered to Marshall for testing. The structural test article will undergo critical testing as engineers push, pull and bend the hardware with millions of pounds of force to ensure it can withstand the forces of launch and ascent. The test hardware is structurally identical to the flight version of the intertank that will connect the core stage's two colossal propellant tanks, serve as the upper-connection point for the two solid rocket boosters and house critical avionics and electronics. Pegasus, originally used during the Space Shuttle Program, has been redesigned and extended to accommodate the SLS rocket's massive, 212-foot-long core stage -- the backbone of the rocket. The 310-foot-long barge will ferry the flight core stage from Michoud to other NASA centers for tests and launch.

  8. Forced Convection Boiling and Critical Heat Flux of Ethanol in Electrically Heated Tube Tests

    NASA Technical Reports Server (NTRS)

    Meyer, Michael L.; Linne, Diane L.; Rousar, Donald C.

    1998-01-01

    Electrically heated tube tests were conducted to characterize the critical heat flux (transition from nucleate to film boiling) of subcritical ethanol flowing at conditions relevant to the design of a regeneratively cooled rocket engine thrust chamber. The coolant was SDA-3C alcohol (95% ethyl alcohol, 5% isopropyl alcohol by weight), and tests were conducted over the following ranges of conditions: pressure from 144 to 703 psia, flow velocities from 9.7 to 77 ft/s, coolant subcooling from 33 to 362 F, and critical heat fluxes up to 8.7 BTU/in(exp 2)/sec. For the data taken near 200 psia, critical heat flux was correlated as a function of the product of velocity and fluid subcooling to within +/- 20%. For data taken at higher pressures, an additional pressure term is needed to correlate the critical heat flux. It was also shown that at the higher test pressures and/or flow rates, exceeding the critical heat flux did not result in wall burnout. This result may significantly increase the engine heat flux design envelope for higher pressure conditions.

  9. Two Questions about Critical-Thinking Tests in Higher Education

    ERIC Educational Resources Information Center

    Benjamin, Roger

    2014-01-01

    In this article, the author argues first, that critical-thinking skills do exist independent of disciplinary thinking skills and are not compromised by interaction effects with the major; and second, that standardized tests (e.g., the Collegiate Learning Assessment, or CLA, which is his example throughout the article) are the best way to measure…

  10. In vitro dynamic solubility test: influence of various parameters.

    PubMed Central

    Thélohan, S; de Meringo, A

    1994-01-01

    This article discusses the dissolution of mineral fibers in simulated physiological fluids (SPF), and the parameters that affect the solubility measurement in a dynamic test where an SPF runs through a cell containing fibers (Scholze and Conradt test). Solutions simulate either the extracellular fluid (pH 7.6) or the intracellular fluid (pH 4.5). The fibers have various chemical compositions and are either continuously drawn or processed as wool. The fiber solubility is determined by the amount of SiO2 (and occasionally other ions) released in the solution. Results are stated as percentage of the initial silica content released or as dissolution rate v in nm/day. The reproducibility of the test is higher with the less soluble fibers (10% solubility), than with highly soluble fibers (20% solubility). The influence of test parameters, including SPF, test duration, and surface area/volume (SA/V), has been studied. The pH and the inorganic buffer salts have a major influence: industrial glasswool composition is soluble at pH 7.6 but not at pH 4.5. The opposite is true for rock- (basalt) wool composition. For slightly soluble fibers, the dissolution rate v remains constant with time, whereas for highly soluble fibers, the dissolution rate decreases rapidly. The dissolution rates believed to occur are v1, initial dissolution rate, and v2, dissolution rate of the residual fibers. The SA of fibers varies with the mass of the fibers tested, or with the fiber diameter at equal mass. Volume, V, is the chosen flow rate. An increase in the SA/V ratio leads to a decrease in the dissolution rate.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7882964

  11. In vitro dynamic solubility test: influence of various parameters.

    PubMed

    Thélohan, S; de Meringo, A

    1994-10-01

    This article discusses the dissolution of mineral fibers in simulated physiological fluids (SPF), and the parameters that affect the solubility measurement in a dynamic test where an SPF runs through a cell containing fibers (Scholze and Conradt test). Solutions simulate either the extracellular fluid (pH 7.6) or the intracellular fluid (pH 4.5). The fibers have various chemical compositions and are either continuously drawn or processed as wool. The fiber solubility is determined by the amount of SiO2 (and occasionally other ions) released in the solution. Results are stated as percentage of the initial silica content released or as dissolution rate v in nm/day. The reproducibility of the test is higher with the less soluble fibers (10% solubility), than with highly soluble fibers (20% solubility). The influence of test parameters, including SPF, test duration, and surface area/volume (SA/V), has been studied. The pH and the inorganic buffer salts have a major influence: industrial glasswool composition is soluble at pH 7.6 but not at pH 4.5. The opposite is true for rock- (basalt) wool composition. For slightly soluble fibers, the dissolution rate v remains constant with time, whereas for highly soluble fibers, the dissolution rate decreases rapidly. The dissolution rates believed to occur are v1, initial dissolution rate, and v2, dissolution rate of the residual fibers. The SA of fibers varies with the mass of the fibers tested, or with the fiber diameter at equal mass. Volume, V, is the chosen flow rate. An increase in the SA/V ratio leads to a decrease in the dissolution rate.(ABSTRACT TRUNCATED AT 250 WORDS)

  12. Evaluation of near-critical overdamping effects in slug-test response

    USGS Publications Warehouse

    Weeks, Edwin P.; Clark, Arthur C.

    2013-01-01

    A slug test behaves as a harmonic oscillator, subject to both inertial effects and viscous damping. When viscous and inertial forces are closely balanced, the system is nearly critically damped, and water-level recovery is affected by inertial effects, but does not exhibit oscillation. These effects were investigated by use of type curves, generated both by modification of Kipp's (1985) computer program and by use of the Butler-Zhan (2004) model. Utility of the type curves was verified by re-analysis of the Regina slug test previously analyzed by Kipp. These type curves indicate that near-critical inertial effects result in early-time delayed water-level response followed by merger with, or more rapid recovery than, response for the fully damped case. Because of this early time response, slug tests in the moderately over-damped range are best analyzed using log-log type curves of (1 − H/H0) vs. Tt/. Failure to recognize inertial effects in slug test data could result in an over-estimate of transmissivity, and a too-small estimate of storage coefficient or too-large estimate of well skin. However, application of the widely used but highly empirical Hvorslev (1951) method to analyze both the Regina slug test and type-curve generated data indicate that such analyses provide T values within a factor of 2 of the true value.

  13. Identifying Critical Road Geometry Parameters Affecting Crash Rate and Crash Type

    PubMed Central

    Othman, Sarbaz; Thomson, Robert; Lannér, Gunnar

    2009-01-01

    The objective of this traffic safety investigation was to find critical road parameters affecting crash rate (CR). The study was based on crash and road maintenance data from Western Sweden. More than 3000 crashes, reported from 2000 to 2005 on median-separated roads, were collected and combined with road geometric and surface data. The statistical analysis showed variations in CR when road elements changed confirming that road characteristics affect CR. The findings indicated that large radii right-turn curves were more dangerous than left curves, in particular, during lane changing manoeuvres. However sharper curves are more dangerous in both left and right curves. Moreover, motorway carriageways with no or limited shoulders have the highest CR when compared to other carriageway widths, while one lane carriageway sections on 2+1 roads were the safest. Road surface results showed that both wheel rut depth and road roughness have negative impacts on traffic safety. PMID:20184841

  14. Physiological Parameters for Oral Delivery and In vitro Testing

    PubMed Central

    Mudie, Deanna M.; Amidon, Gordon L.; Amidon, Gregory E.

    2010-01-01

    Pharmaceutical solid oral dosage forms must undergo dissolution in the intestinal fluids of the gastrointestinal tract before they can be absorbed and reach the systemic circulation. Therefore, dissolution is a critical part of the drug-delivery process. The rate and extent of drug dissolution and absorption depend on the characteristics of the active ingredient as well as properties of the dosage form. Just as importantly, characteristics of the physiological environment such as buffer species, pH, bile salts, gastric emptying rate, intestinal motility, and hydrodynamics can significantly impact dissolution and absorption. While significant progress has been made since 1970 when the first compendial dissolution test was introduced (USP Apparatus 1), current dissolution testing does not take full advantage of the extensive physiologic information that is available. For quality control purposes, where the question is one of lot-to-lot consistency in performance, using nonphysiologic test conditions that match drug and dosage form properties with practical dissolution media and apparatus may be appropriate. However, where in vitro – in vivo correlations are desired, it is logical to consider and utilize knowledge of the in vivo condition. This publication critically reviews the literature that is relevant to oral human drug delivery. Physiologically relevant information must serve as a basis for the design of dissolution test methods and systems that are more representative of the human condition. As in vitro methods advance in their physiological relevance, better in vitro - in vivo correlations will be possible. This will, in turn, lead to in vitro systems that can be utilized to more effectively design dosage forms that have improved and more consistent oral bioperformance. PMID:20822152

  15. An Analytical Approach to Obtaining JWL Parameters from Cylinder Tests

    NASA Astrophysics Data System (ADS)

    Sutton, Ben; Ferguson, James

    2015-06-01

    An analytical method for determining parameters for the JWL equation of state (EoS) from cylinder test data is described. This method is applied to four datasets obtained from two 20.3 mm diameter EDC37 cylinder tests. The calculated parameters and pressure-volume (p-V) curves agree with those produced by hydro-code modelling. The calculated Chapman-Jouguet (CJ) pressure is 38.6 GPa, compared to the model value of 38.3 GPa; the CJ relative volume is 0.729 for both. The analytical pressure-volume curves produced agree with the one used in the model out to the commonly reported expansion of 7 relative volumes, as do the predicted energies generated by integrating under the p-V curve. The calculated and model energies are 8.64 GPa and 8.76 GPa respectively.

  16. Comparison of Critical Power and W' Derived From 2 or 3 Maximal Tests.

    PubMed

    Simpson, Len Parker; Kordi, Mehdi

    2017-07-01

    Typically, accessing the asymptote (critical power; CP) and curvature constant (W') parameters of the hyperbolic power-duration relationship requires multiple constant-power exhaustive-exercise trials spread over several visits. However, more recently single-visit protocols and personal power meters have been used. This study investigated the practicality of using a 2-trial, single-visit protocol in providing reliable CP and W' estimates. Eight trained cyclists underwent 3- and 12-min maximal-exercise trials in a single session to derive (2-trial) CP and W' estimates. On a separate occasion a 5-min trial was performed, providing a 3rd trial to calculate (3-trial) CP and W'. There were no differences in CP (283 ± 66 vs 282 ± 65 W) or W' (18.72 ± 6.21 vs 18.27 ± 6.29 kJ) obtained from either the 2-trial or 3-trial method, respectively. After 2 familiarization sessions (completing a 3- and a 12-min trial on both occasions), both CP and W' remained reliable over additional separate measurements. The current study demonstrates that after 2 familiarization sessions, reliable CP and W' parameters can be obtained from trained cyclists using only 2 maximal-exercise trials. These results offer practitioners a practical, time-efficient solution for incorporating power-duration testing into applied athlete support.

  17. New parameters in adaptive testing of ferromagnetic materials utilizing magnetic Barkhausen noise

    NASA Astrophysics Data System (ADS)

    Pal'a, Jozef; Ušák, Elemír

    2016-03-01

    A new method of magnetic Barkhausen noise (MBN) measurement and optimization of the measured data processing with respect to non-destructive evaluation of ferromagnetic materials was tested. Using this method we tried to found, if it is possible to enhance sensitivity and stability of measurement results by replacing the traditional MBN parameter (root mean square) with some new parameter. In the tested method, a complex set of the MBN from minor hysteresis loops is measured. Afterward, the MBN data are collected into suitably designed matrices and optimal parameters of MBN with respect to maximum sensitivity to the evaluated variable are searched. The method was verified on plastically deformed steel samples. It was shown that the proposed measuring method and measured data processing bring an improvement of the sensitivity to the evaluated variable when comparing with measuring traditional MBN parameter. Moreover, we found a parameter of MBN, which is highly resistant to the changes of applied field amplitude and at the same time it is noticeably more sensitive to the evaluated variable.

  18. Use of Multi-Response Format Test in the Assessment of Medical Students' Critical Thinking Ability.

    PubMed

    Mafinejad, Mahboobeh Khabaz; Arabshahi, Seyyed Kamran Soltani; Monajemi, Alireza; Jalili, Mohammad; Soltani, Akbar; Rasouli, Javad

    2017-09-01

    To evaluate students critical thinking skills effectively, change in assessment practices is must. The assessment of a student's ability to think critically is a constant challenge, and yet there is considerable debate on the best assessment method. There is evidence that the intrinsic nature of open and closed-ended response questions is to measure separate cognitive abilities. To assess critical thinking ability of medical students by using multi-response format of assessment. A cross-sectional study was conducted on a group of 159 undergraduate third-year medical students. All the participants completed the California Critical Thinking Skills Test (CCTST) consisting of 34 multiple-choice questions to measure general critical thinking skills and a researcher-developed test that combines open and closed-ended questions. A researcher-developed 48-question exam, consisting of 8 short-answers and 5 essay questions, 19 Multiple-Choice Questions (MCQ), and 16 True-False (TF) questions, was used to measure critical thinking skills. Correlation analyses were performed using Pearson's coefficient to explore the association between the total scores of tests and subtests. One hundred and fifty-nine students participated in this study. The sample comprised 81 females (51%) and 78 males (49%) with an age range of 20±2.8 years (mean 21.2 years). The response rate was 64.1%. A significant positive correlation was found between types of questions and critical thinking scores, of which the correlations of MCQ (r=0.82) and essay questions (r=0.77) were strongest. The significant positive correlations between multi-response format test and CCTST's subscales were seen in analysis, evaluation, inference and inductive reasoning. Unlike CCTST subscales, multi-response format test have weak correlation with CCTST total score (r=0.45, p=0.06). This study highlights the importance of considering multi-response format test in the assessment of critical thinking abilities of medical

  19. Use of Multi-Response Format Test in the Assessment of Medical Students’ Critical Thinking Ability

    PubMed Central

    Mafinejad, Mahboobeh Khabaz; Monajemi, Alireza; Jalili, Mohammad; Soltani, Akbar; Rasouli, Javad

    2017-01-01

    Introduction To evaluate students critical thinking skills effectively, change in assessment practices is must. The assessment of a student’s ability to think critically is a constant challenge, and yet there is considerable debate on the best assessment method. There is evidence that the intrinsic nature of open and closed-ended response questions is to measure separate cognitive abilities. Aim To assess critical thinking ability of medical students by using multi-response format of assessment. Materials and Methods A cross-sectional study was conducted on a group of 159 undergraduate third-year medical students. All the participants completed the California Critical Thinking Skills Test (CCTST) consisting of 34 multiple-choice questions to measure general critical thinking skills and a researcher-developed test that combines open and closed-ended questions. A researcher-developed 48-question exam, consisting of 8 short-answers and 5 essay questions, 19 Multiple-Choice Questions (MCQ), and 16 True-False (TF) questions, was used to measure critical thinking skills. Correlation analyses were performed using Pearson’s coefficient to explore the association between the total scores of tests and subtests. Results One hundred and fifty-nine students participated in this study. The sample comprised 81 females (51%) and 78 males (49%) with an age range of 20±2.8 years (mean 21.2 years). The response rate was 64.1%. A significant positive correlation was found between types of questions and critical thinking scores, of which the correlations of MCQ (r=0.82) and essay questions (r=0.77) were strongest. The significant positive correlations between multi-response format test and CCTST’s subscales were seen in analysis, evaluation, inference and inductive reasoning. Unlike CCTST subscales, multi-response format test have weak correlation with CCTST total score (r=0.45, p=0.06). Conclusion This study highlights the importance of considering multi-response format test in

  20. Dynamical susceptibility near a long-wavelength critical point with a nonconserved order parameter

    NASA Astrophysics Data System (ADS)

    Klein, Avraham; Lederer, Samuel; Chowdhury, Debanjan; Berg, Erez; Chubukov, Andrey

    2018-04-01

    We study the dynamic response of a two-dimensional system of itinerant fermions in the vicinity of a uniform (Q =0 ) Ising nematic quantum critical point of d - wave symmetry. The nematic order parameter is not a conserved quantity, and this permits a nonzero value of the fermionic polarization in the d - wave channel even for vanishing momentum and finite frequency: Π (q =0 ,Ωm)≠0 . For weak coupling between the fermions and the nematic order parameter (i.e., the coupling is small compared to the Fermi energy), we perturbatively compute Π (q =0 ,Ωm)≠0 over a parametrically broad range of frequencies where the fermionic self-energy Σ (ω ) is irrelevant, and use Eliashberg theory to compute Π (q =0 ,Ωm) in the non-Fermi-liquid regime at smaller frequencies, where Σ (ω )>ω . We find that Π (q =0 ,Ω ) is a constant, plus a frequency-dependent correction that goes as |Ω | at high frequencies, crossing over to |Ω| 1 /3 at lower frequencies. The |Ω| 1 /3 scaling holds also in a non-Fermi-liquid regime. The nonvanishing of Π (q =0 ,Ω ) gives rise to additional structure in the imaginary part of the nematic susceptibility χ″(q ,Ω ) at Ω >vFq , in marked contrast to the behavior of the susceptibility for a conserved order parameter. This additional structure may be detected in Raman scattering experiments in the d - wave geometry.

  1. Molecular dynamics study of combustion reactions in supercritical environment. Part 1: Carbon dioxide and water force field parameters refitting and critical isotherms of binary mixtures

    DOE PAGES

    Masunov, Artem E.; Atlanov, Arseniy Alekseyevich; Vasu, Subith S.

    2016-10-04

    Oxy-fuel combustion process is expected to drastically increase the energy efficiency and enable easy carbon sequestration. In this technology the combustion products (carbon dioxide and water) are used to control the temperature and nitrogen is excluded from the combustion chamber, so that nitrogen oxide pollutants do not form. Therefore, in oxycombustion the carbon dioxide and water are present in large concentrations in their transcritical state, and may play an important role in kinetics. The computational chemistry methods may assist in understanding these effects, and Molecular Dynamics with ReaxFF force field seem to be a suitable tool for such a study.more » Here we investigate applicability of the ReaxFF to describe the critical phenomena in carbon dioxide and water and find that several nonbonding parameters need adjustment. We report the new parameter set, capable to reproduce the critical temperatures and pressures. Furthermore, the critical isotherms of CO 2/H 2O binary mixtures are computationally studied here for the first time and their critical parameters are reported.« less

  2. Molecular dynamics study of combustion reactions in supercritical environment. Part 1: Carbon dioxide and water force field parameters refitting and critical isotherms of binary mixtures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masunov, Artem E.; Atlanov, Arseniy Alekseyevich; Vasu, Subith S.

    Oxy-fuel combustion process is expected to drastically increase the energy efficiency and enable easy carbon sequestration. In this technology the combustion products (carbon dioxide and water) are used to control the temperature and nitrogen is excluded from the combustion chamber, so that nitrogen oxide pollutants do not form. Therefore, in oxycombustion the carbon dioxide and water are present in large concentrations in their transcritical state, and may play an important role in kinetics. The computational chemistry methods may assist in understanding these effects, and Molecular Dynamics with ReaxFF force field seem to be a suitable tool for such a study.more » Here we investigate applicability of the ReaxFF to describe the critical phenomena in carbon dioxide and water and find that several nonbonding parameters need adjustment. We report the new parameter set, capable to reproduce the critical temperatures and pressures. Furthermore, the critical isotherms of CO 2/H 2O binary mixtures are computationally studied here for the first time and their critical parameters are reported.« less

  3. Setting accelerated dissolution test for PLGA microspheres containing peptide, investigation of critical parameters affecting drug release rate and mechanism.

    PubMed

    Tomic, I; Vidis-Millward, A; Mueller-Zsigmondy, M; Cardot, J-M

    2016-05-30

    The objective of this study was development of accelerated in vitro release method for peptide loaded PLGA microspheres using flow-through apparatus and assessment of the effect of dissolution parameters (pH, temperature, medium composition) on drug release rate and mechanism. Accelerated release conditions were set as pH 2 and 45°C, in phosphate buffer saline (PBS) 0.02M. When the pH was changed from 2 to 4, diffusion controlled phases (burst and lag) were not affected, while release rate during erosion phase decreased two-fold due to slower ester bonds hydrolyses. Decreasing temperature from 45°C to 40°C, release rate showed three-fold deceleration without significant change in release mechanism. Effect of medium composition on drug release was tested in PBS 0.01M (200 mOsm/kg) and PBS 0.01M with glucose (380 mOsm/kg). Buffer concentration significantly affected drug release rate and mechanism due to the change in osmotic pressure, while ionic strength did not have any effect on peptide release. Furthermore, dialysis sac and sample-and-separate techniques were used, in order to evaluate significance of dissolution technique choice on the release process. After fitting obtained data to different mathematical models, flow-through method was confirmed as the most appropriate for accelerated in vitro dissolution testing for a given formulation. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. White Dwarf Critical Tests for Modified Gravity.

    PubMed

    Jain, Rajeev Kumar; Kouvaris, Chris; Nielsen, Niklas Grønlund

    2016-04-15

    Scalar-tensor theories of gravity can lead to modifications of the gravitational force inside astrophysical objects. We exhibit that compact stars such as white dwarfs provide a unique setup to test beyond Horndeski theories of G^{3} type. We obtain stringent and independent constraints on the parameter ϒ characterizing the deviations from Newtonian gravity using the mass-radius relation, the Chandrasekhar mass limit, and the maximal rotational frequency of white dwarfs. We find that white dwarfs impose stronger constraints on ϒ than red and brown dwarfs.

  5. Effect of Critical Displacement Parameter on Slip Regime at Subduction Fault

    NASA Astrophysics Data System (ADS)

    Muldashev, Iskander; Sobolev, Stephan

    2016-04-01

    It is widely accepted that for the simple fault models value of critical displacement parameter (Dc) in Ruina-Dietrich's rate-and-state friction law is responsible for the transition from stick-slip regime at low Dc to non-seismic creep regime at large Dc. However, neither the value of "transition" Dc parameter nor the character of the transition is known for the realistic subduction zone setting. Here we investigate effect of Dc on regime of slip at subduction faults for two setups, generic model similar to simple shear elastic slider under quasistatic loading and full subduction model with appropriate geometry, stress and temperature distribution similar to the setting at the site of the Great Chile Earthquake of 1960. In our modeling we use finite element numerical technique that employs non-linear elasto-visco-plastic rheology in the entire model domain with rate-and-state plasticity within the fault zone. The model generates spontaneous earthquake sequence. Adaptive time-step integration procedure varies time step from 40 seconds at instability (earthquake), and gradually increases it to 5 years during postseismic relaxation. The technique allows observing the effect of Dc on period, magnitude of earthquakes through the cycles. We demonstrate that our modeling results for the generic model are consistent with the previous theoretical and numeric modeling results. For the full subduction model we obtain transition from non-seismic creep to stick-slip regime at Dc about 20 cm. We will demonstrate and discuss the features of the transition regimes in both generic and realistic subduction models.

  6. Computer-aided testing of pilot response to critical in-flight events

    NASA Technical Reports Server (NTRS)

    Giffin, W. C.; Rockwell, T. H.

    1984-01-01

    This research on pilot response to critical in-flight events employs a unique methodology including an interactive computer-aided scenario-testing system. Navigation displays, instrument-panel displays, and assorted textual material are presented on a touch-sensitive CRT screen. Problem diagnosis scenarios, destination-diversion scenarios and combined destination/diagnostic tests are available. A complete time history of all data inquiries and responses is maintained. Sample results of diagnosis scenarios obtained from testing 38 licensed pilots are presented and discussed.

  7. Critical Surface Parameters for the Oxidative Coupling of Methane over the Mn-Na-W/SiO2 Catalyst.

    PubMed

    Hayek, Naseem S; Lucas, Nishita S; Warwar Damouny, Christine; Gazit, Oz M

    2017-11-22

    The work here presents a thorough evaluation of the effect of Mn-Na-W/SiO 2 catalyst surface parameters on its performance in the oxidative coupling of methane (OCM). To do so, we used microporous dealuminated β-zeolite (Zeo), or mesoporous SBA-15 (SBA), or macroporous fumed silica (Fum) as precursors for catalyst preparation, together with Mn nitrate, Mn acetate and Na 2 WO 4 . Characterizing the catalysts by inductively coupled plasma-optical emission spectroscopy, N 2 physisorption, X-ray diffraction, high-resolution scanning electron microscopy-energy-dispersive spectroscopy, X-ray photoelectron spectroscopy, and catalytic testing enabled us to identify critical surface parameters that govern the activity and C 2 selectivity of the Mn-Na-W/SiO 2 catalyst. Although the current paradigm views the phase transition of silica to α-cristobalite as the critical step in obtaining dispersed and stable metal sites, we show that the choice of precursors is equally or even more important with respect to tailoring the right surface properties. Specifically, the SBA-based catalyst, characterized by relatively closed surface porosity, demonstrated low activity and low C 2 selectivity. By contrast, for the same composition, the Zeo-based catalyst showed an open surface pore structure, which translated up to fourfold higher activity and enhanced selectivity. By varying the overall composition of the Zeo catalysts, we show that reducing the overall W concentration reduces the size of the Na 2 WO 4 species and increases the catalytic activity linearly as much as fivefold higher than the SBA catalyst. This linear dependence correlates well to the number of interfaces between the Na 2 WO 4 and Mn 2 O 3 species. Our results combined with prior studies lead us to single out the interface between Na 2 WO 4 and Mn 2 O 3 as the most probable active site for OCM using this catalyst. Synergistic interactions between the various precursors used and the phase transition are discussed in

  8. Unscented Kalman filter with parameter identifiability analysis for the estimation of multiple parameters in kinetic models

    PubMed Central

    2011-01-01

    In systems biology, experimentally measured parameters are not always available, necessitating the use of computationally based parameter estimation. In order to rely on estimated parameters, it is critical to first determine which parameters can be estimated for a given model and measurement set. This is done with parameter identifiability analysis. A kinetic model of the sucrose accumulation in the sugar cane culm tissue developed by Rohwer et al. was taken as a test case model. What differentiates this approach is the integration of an orthogonal-based local identifiability method into the unscented Kalman filter (UKF), rather than using the more common observability-based method which has inherent limitations. It also introduces a variable step size based on the system uncertainty of the UKF during the sensitivity calculation. This method identified 10 out of 12 parameters as identifiable. These ten parameters were estimated using the UKF, which was run 97 times. Throughout the repetitions the UKF proved to be more consistent than the estimation algorithms used for comparison. PMID:21989173

  9. Critical Parameters of the Initiation Zone for Spontaneous Dynamic Rupture Propagation

    NASA Astrophysics Data System (ADS)

    Galis, M.; Pelties, C.; Kristek, J.; Moczo, P.; Ampuero, J. P.; Mai, P. M.

    2014-12-01

    Numerical simulations of rupture propagation are used to study both earthquake source physics and earthquake ground motion. Under linear slip-weakening friction, artificial procedures are needed to initiate a self-sustained rupture. The concept of an overstressed asperity is often applied, in which the asperity is characterized by its size, shape and overstress. The physical properties of the initiation zone may have significant impact on the resulting dynamic rupture propagation. A trial-and-error approach is often necessary for successful initiation because 2D and 3D theoretical criteria for estimating the critical size of the initiation zone do not provide general rules for designing 3D numerical simulations. Therefore, it is desirable to define guidelines for efficient initiation with minimal artificial effects on rupture propagation. We perform an extensive parameter study using numerical simulations of 3D dynamic rupture propagation assuming a planar fault to examine the critical size of square, circular and elliptical initiation zones as a function of asperity overstress and background stress. For a fixed overstress, we discover that the area of the initiation zone is more important for the nucleation process than its shape. Comparing our numerical results with published theoretical estimates, we find that the estimates by Uenishi & Rice (2004) are applicable to configurations with low background stress and small overstress. None of the published estimates are consistent with numerical results for configurations with high background stress. We therefore derive new equations to estimate the initiation zone size in environments with high background stress. Our results provide guidelines for defining the size of the initiation zone and overstress with minimal effects on the subsequent spontaneous rupture propagation.

  10. 30 CFR 27.35 - Tests to determine life of critical components and subassemblies.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Tests to determine life of critical components and subassemblies. 27.35 Section 27.35 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test...

  11. 30 CFR 27.35 - Tests to determine life of critical components and subassemblies.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Tests to determine life of critical components and subassemblies. 27.35 Section 27.35 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS Test...

  12. Developing Science Virtual Test to Measure Students’ Critical Thinking on Living Things and Environmental Sustainability Theme

    NASA Astrophysics Data System (ADS)

    Akbar, M. N.; Firman, H.; Rusyati, L.

    2017-02-01

    Critical thinking is skill and ability to use of risk taking creativity to make a decision and knowledge as a result, analysis and synthesis that, evaluation, to acquire, information search, to develop thinking, as an individual aware of his or her own thinking. The aim of this study is to develop the science virtual test to measure students’ critical thinking on living things and environmental sustainability theme. The research method that is used in this research was descriptive research. The development of science virtual test item consist of five steps: (1) content analysis; (2) constructing the instrument (multiple choice) based on the elements of critical thinking by Inch; (3) validity judgment of the instrument by the expert; (4) legibility test of the instrument; (5) conducting the large field test. On the large field test was gained the results of validity and reliability of the test, difficulty index, discriminating power, and quality of distractor. The subjects of research were 8th grade students at International Junior High School in Bandung with 125 total of respondents. The coefficient alpha (α) was 0.747, the reliability of the test was categorized as ‘high’ and value of RXY correlation was 0.63 which mean that the validity of the test was categorized as ‘high’. These means that science virtual test can be used to measure student’s critical thinking with a good consistency. It is expected for other researcher to take this description as one of the basic information to be considered in developing science virtual test for improving students’ critical thinking by various kind of topic.

  13. Estimating free-body modal parameters from tests of a constrained structure

    NASA Technical Reports Server (NTRS)

    Cooley, Victor M.

    1993-01-01

    Hardware advances in suspension technology for ground tests of large space structures provide near on-orbit boundary conditions for modal testing. Further advances in determining free-body modal properties of constrained large space structures have been made, on the analysis side, by using time domain parameter estimation and perturbing the stiffness of the constraints over multiple sub-tests. In this manner, passive suspension constraint forces, which are fully correlated and therefore not usable for spectral averaging techniques, are made effectively uncorrelated. The technique is demonstrated with simulated test data.

  14. Critical joints in large composite primary aircraft structures. Volume 2: Technology demonstration test report

    NASA Technical Reports Server (NTRS)

    Bunin, Bruce L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints in composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of four large composite multirow bolted joint tests are presented. The tests were conducted to demonstrate the technology for critical joints in highly loaded composite structure and to verify the analytical methods that were developed throughout the program. The test consisted of a wing skin-stringer transition specimen representing a stringer runout and skin splice on the wing lower surface at the side of the fuselage attachment. All tests were static tension tests. The composite material was Toray T-300 fiber with Ciba-Geigy 914 resin in 10 mil tape form. The splice members were metallic, using combinations of aluminum and titanium. Discussions are given of the test article, instrumentation, test setup, test procedures, and test results for each of the four specimens. Some of the analytical predictions are also included.

  15. Impact force as a scaling parameter

    NASA Technical Reports Server (NTRS)

    Poe, Clarence C., Jr.; Jackson, Wade C.

    1994-01-01

    The Federal Aviation Administration (FAR PART 25) requires that a structure carry ultimate load with nonvisible impact damage and carry 70 percent of limit flight loads with discrete damage. The Air Force has similar criteria (MIL-STD-1530A). Both civilian and military structures are designed by a building block approach. First, critical areas of the structure are determined, and potential failure modes are identified. Then, a series of representative specimens are tested that will fail in those modes. The series begins with tests of simple coupons, progresses through larger and more complex subcomponents, and ends with a test on a full-scale component, hence the term 'building block.' In order to minimize testing, analytical models are needed to scale impact damage and residual strength from the simple coupons to the full-scale component. Using experiments and analysis, the present paper illustrates that impact damage can be better understood and scaled using impact force than just kinetic energy. The plate parameters considered are size and thickness, boundary conditions, and material, and the impact parameters are mass, shape, and velocity.

  16. Insights into the base of the critical zone from geophysical logging and groundwater flow testing at U.S. Critical Zone Observatories (CZO) and critical zone study sites (CZs)

    NASA Astrophysics Data System (ADS)

    Carr, B.; Zhang, Y.; Ren, S.; Flinchum, B. A.; Parsekian, A.; Holbrook, S.; Riebe, C. S.; Moravec, B. G.; Chorover, J.; Pelletier, J. D.; Richter, D. D., Jr.

    2017-12-01

    Four prominent hypotheses exist and predict conceptual models defining the base of the critical zone. These hypotheses lack insights and constraints from borehole data since few deep (> 20 m) boreholes (and even fewer connected wellfields) are present in the U.S. Critical Zone Observatories (CZO) and similar critical zone study sites (CZs). The influence and interaction of fracture presence, fracture density, fracture orientation, groundwater presence and groundwater flow have only begun to be analyzed relative to any definition of the base of the critical zone. In this presentation, we examine each hypothesis by jointly evaluating borehole geophysical logs and groundwater testing datasets collected by the Wyoming Center for Environmental Hydrology and Geophysics (WyCEHG) since 2014 at these deep CZO or CZ boreholes. Deep boreholes allow a unique opportunity to observe the factors influencing groundwater transmissivity/storage capacity within the three main subsurface CZ layers: Unconsolidated (soil/saprolite), Fractured/weathered Bedrock, and Protolith bedrock (i.e. less fractured bedrock). The boreholes used in this study consist of: 1) nine wells of the Blair-Wallis (WY) WyCEHG CZ, 2) two wells in Catalina-Jemez CZO (Valle Caldera NM) and 3) one borehole at the Calhoun (SC) CZO. At this time, these are the only sites that contain boreholes with depths ranging from at least 20 m up to 70m that have been geophysically logged with full-waveform seismic, acoustic and optical televiewer, electric, electromagnetic, flowmeter (impeller and heat pulse), fluid temperature, fluid conductivity and nuclear magnetic resonance. Further, the Blair-Wallis CZ site contains five hydraulically connected wells that allow us to estimate formation transmissivity and storage coefficients at increasing scales by conducting: slug tests, FLUTe™ borehole profiling, and cross-hole pumping tests. These well tests provide direct hydraulic data of the bedrock (both fractured and protolith

  17. Modeling of the dolphin's clicking sound source: The influence of the critical parameters

    NASA Astrophysics Data System (ADS)

    Dubrovsky, N. A.; Gladilin, A.; Møhl, B.; Wahlberg, M.

    2004-07-01

    A physical and a mathematical models of the dolphin’s source of echolocation clicks have been recently proposed. The physical model includes a bottle of pressurized air connected to the atmosphere with an underwater rubber tube. A compressing rubber ring is placed on the underwater portion of the tube. The ring blocks the air jet passing through the tube from the bottle. This ring can be brought into self-oscillation by the air jet. In the simplest case, the ring displacement follows a repeated triangular waveform. Because the acoustic pressure gradient is proportional to the second time derivative of the displacement, clicks arise at the bends of the displacement waveform. The mathematical model describes the dipole oscillations of a sphere “frozen” in the ring and calculates the waveform and the sound pressure of the generated clicks. The critical parameters of the mathematical model are the radius of the sphere and the peak value and duration of the triangular displacement curve. This model allows one to solve both the forward (deriving the properties of acoustic clicks from the known source parameters) and the inverse (calculating the source parameters from the acoustic data) problems. Data from click records of Odontocetes were used to derive both the displacement waveforms and the size of the “frozen sphere” or a structure functionally similar to it. The mathematical model predicts a maximum source level of up to 235 dB re 1 μPa at 1-m range when using a 5-cm radius of the “frozen” sphere and a 4-mm maximal displacement. The predicted sound pressure level is similar to that of the clicks produced by Odontocetest.

  18. [Team approaches to critical bleeding (massive bleeding and transfusion) - chairmen's introductory remarks. Questionnaire survey on current status of hospital clinical laboratories evaluating critical hemorrhage].

    PubMed

    Kino, Shuichi; Suwabe, Akira

    2014-12-01

    In 2007, "the Guidelines for Actions against Intraoperative Critical Hemorrhage" were established by the Japanese Society of Anaesthesiologists and the Japanese Society of Blood transfusion and Cell Therapy. The documentation of in-hospital procedures for critical hemorrhage, especially about how to select RBC units, has widely standardized hospital practice. Patients with intraoperative critical hemorrhage sometimes suffer from massive blood loss. In this situation, some patients develop coagulopathy. To treat them, we need to evaluate their coagulation status based on laboratory test results. So, we performed a nationwide questionnaire survey on the current status of hospital clinical laboratories evaluating critical hemorrhage. From the results of this survey, it was recommended that central hospital laboratories should try to reduce the turn-around time required to test for coagulation parameters as much as possible for appropriate substitution therapy. (Review).

  19. Tracer SWIW tests in propped and un-propped fractures: parameter sensitivity issues, revisited

    NASA Astrophysics Data System (ADS)

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2017-04-01

    Single-well injection-withdrawal (SWIW) or 'push-then-pull' tracer methods appear attractive for a number of reasons: less uncertainty on design and dimensioning, and lower tracer quantities required than for inter-well tests; stronger tracer signals, enabling easier and cheaper metering, and shorter metering duration required, reaching higher tracer mass recovery than in inter-well tests; last not least: no need for a second well. However, SWIW tracer signal inversion faces a major issue: the 'push-then-pull' design weakens the correlation between tracer residence times and georeservoir transport parameters, inducing insensitivity or ambiguity of tracer signal inversion w. r. to some of those georeservoir parameters that are supposed to be the target of tracer tests par excellence: pore velocity, transport-effective porosity, fracture or fissure aperture and spacing or density (where applicable), fluid/solid or fluid/fluid phase interface density. Hydraulic methods cannot measure the transport-effective values of such parameters, because pressure signals correlate neither with fluid motion, nor with material fluxes through (fluid-rock, or fluid-fluid) phase interfaces. The notorious ambiguity impeding parameter inversion from SWIW test signals has nourished several 'modeling attitudes': (i) regard dispersion as the key process encompassing whatever superposition of underlying transport phenomena, and seek a statistical description of flow-path collectives enabling to characterize dispersion independently of any other transport parameter, as proposed by Gouze et al. (2008), with Hansen et al. (2016) offering a comprehensive analysis of the various ways dispersion model assumptions interfere with parameter inversion from SWIW tests; (ii) regard diffusion as the key process, and seek for a large-time, asymptotically advection-independent regime in the measured tracer signals (Haggerty et al. 2001), enabling a dispersion-independent characterization of multiple

  20. Optimization of BI test parameters to investigate mechanical properties of Grade 92 steel

    NASA Astrophysics Data System (ADS)

    Barbadikar, Dipika R.; Vincent, S.; Ballal, Atul R.; Peshwe, Dilip R.; Mathew, M. D.

    2018-04-01

    The ball indentation (BI) testing is used to evaluate the tensile properties of materials namely yield strength, strength coefficient, ultimate tensile strength, and strain hardening exponent. The properties evaluated depend on a number of BI test parameters. These parameters include the material constants like yield slope (YS), constraint factor (CF), yield offset parameter (YOP). Number of loading/unloading cycles, preload, indenter size and depth of penetration of indenter also affects the properties. In present investigation the effect of these parameters on the stress-strain curve of normalized and tempered Grade 92 steel is evaluated. Grade 92 is a candidate material for power plant application over austenitic stainless steel and derives its strength from M23C6, MX precipitates and high dislocation density. CF, YS and YOP changed the strength properties considerably. Indenter size effect resulted in higher strength for smaller indenter. It is suggested to use larger indenter diameter and higher number of loading cycles for GRADE 92 steel to get best results using BI technique.

  1. Benchmark Testing of a New 56Fe Evaluation for Criticality Safety Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Leal, Luiz C; Ivanov, E.

    2015-01-01

    The SAMMY code was used to evaluate resonance parameters of the 56Fe cross section in the resolved resonance energy range of 0–2 MeV using transmission data, capture, elastic, inelastic, and double differential elastic cross sections. The resonance analysis was performed with the code SAMMY that fits R-matrix resonance parameters using the generalized least-squares technique (Bayes’ theory). The evaluation yielded a set of resonance parameters that reproduced the experimental data very well, along with a resonance parameter covariance matrix for data uncertainty calculations. Benchmark tests were conducted to assess the evaluation performance in benchmark calculations.

  2. Theory of Metastable State Relaxation in a Gravitational Field for Non-Critical Binary Systems with Non-Conserved Order Parameter

    NASA Technical Reports Server (NTRS)

    Izmailov, Alexander F.; Myerson, Allan S.

    1993-01-01

    A new mathematical ansatz is developed for solution of the time-dependent Ginzburg-Landau nonlinear partial differential equation describing metastable state relaxation in binary (solute+solvent) non-critical solutions with non-conserved scalar order parameter in presence of a gravitational field. It has been demonstrated analytically that in such systems metastability initiates heterogeneous solute redistribution which results in the formation of a non-equilibrium singly-periodic spatial solute structure in the new solute-rich phase. The critical radius of nucleation and the induction time in these systems are gravity-dependent. It has also been proved that metastable state relaxation in vertical columns of supersaturated non-critical binary solutions leads to formation of the solute concentration gradient. Analytical expression for this concentration gradient is found and analysed. It is concluded that gravity can initiate phase separation (nucleation or spinodal decomposition).

  3. Workflow for Criticality Assessment Applied in Biopharmaceutical Process Validation Stage 1.

    PubMed

    Zahel, Thomas; Marschall, Lukas; Abad, Sandra; Vasilieva, Elena; Maurer, Daniel; Mueller, Eric M; Murphy, Patrick; Natschläger, Thomas; Brocard, Cécile; Reinisch, Daniela; Sagmeister, Patrick; Herwig, Christoph

    2017-10-12

    Identification of critical process parameters that impact product quality is a central task during regulatory requested process validation. Commonly, this is done via design of experiments and identification of parameters significantly impacting product quality (rejection of the null hypothesis that the effect equals 0). However, parameters which show a large uncertainty and might result in an undesirable product quality limit critical to the product, may be missed. This might occur during the evaluation of experiments since residual/un-modelled variance in the experiments is larger than expected a priori. Estimation of such a risk is the task of the presented novel retrospective power analysis permutation test. This is evaluated using a data set for two unit operations established during characterization of a biopharmaceutical process in industry. The results show that, for one unit operation, the observed variance in the experiments is much larger than expected a priori, resulting in low power levels for all non-significant parameters. Moreover, we present a workflow of how to mitigate the risk associated with overlooked parameter effects. This enables a statistically sound identification of critical process parameters. The developed workflow will substantially support industry in delivering constant product quality, reduce process variance and increase patient safety.

  4. Predicting Performance on a Firefighter's Ability Test from Fitness Parameters

    ERIC Educational Resources Information Center

    Michaelides, Marcos A.; Parpa, Koulla M.; Thompson, Jerald; Brown, Barry

    2008-01-01

    The purpose of this project was to identify the relationships between various fitness parameters such as upper body muscular endurance, upper and lower body strength, flexibility, body composition and performance on an ability test (AT) that included simulated firefighting tasks. A second intent was to create a regression model that would predict…

  5. New Comment on Gibbs Density Surface of Fluid Argon: Revised Critical Parameters, L. V. Woodcock, Int. J. Thermophys. (2014) 35, 1770-1784

    NASA Astrophysics Data System (ADS)

    Umirzakov, I. H.

    2018-01-01

    The author comments on an article by Woodcock (Int J Thermophys 35:1770-1784, 2014), who investigates the idea of a critical line instead of a single critical point using the example of argon. In the introduction, Woodcock states that "The Van der Waals critical point does not comply with the Gibbs phase rule. Its existence is based upon a hypothesis rather than a thermodynamic definition". The present comment is a response to the statement by Woodcock. The comment mathematically demonstrates that a critical point is not only based on a hypothesis that is used to define values of two parameters of the Van der Waals equation of state. Instead, the author argues that a critical point is a direct consequence of the thermodynamic phase equilibrium conditions resulting in a single critical point. It is shown that the thermodynamic conditions result in the first and second partial derivatives of pressure with respect to volume at constant temperature at a critical point equal to zero which are usual conditions of an existence of a critical point.

  6. Finite-sample and asymptotic sign-based tests for parameters of non-linear quantile regression with Markov noise

    NASA Astrophysics Data System (ADS)

    Sirenko, M. A.; Tarasenko, P. F.; Pushkarev, M. I.

    2017-01-01

    One of the most noticeable features of sign-based statistical procedures is an opportunity to build an exact test for simple hypothesis testing of parameters in a regression model. In this article, we expanded a sing-based approach to the nonlinear case with dependent noise. The examined model is a multi-quantile regression, which makes it possible to test hypothesis not only of regression parameters, but of noise parameters as well.

  7. An effective combined environment test facility

    NASA Technical Reports Server (NTRS)

    Deitch, A.

    1980-01-01

    A critical missile component required operational verification while subjected to combined environments within and beyond flight parameters. The testing schedule necessitated the design and fabrication of a test facility in order to provide the specified temperatures combined with humidity, altitude and vibration.

  8. Parameter screening: the use of a dummy parameter to identify non-influential parameters in a global sensitivity analysis

    NASA Astrophysics Data System (ADS)

    Khorashadi Zadeh, Farkhondeh; Nossent, Jiri; van Griensven, Ann; Bauwens, Willy

    2017-04-01

    Parameter estimation is a major concern in hydrological modeling, which may limit the use of complex simulators with a large number of parameters. To support the selection of parameters to include in or exclude from the calibration process, Global Sensitivity Analysis (GSA) is widely applied in modeling practices. Based on the results of GSA, the influential and the non-influential parameters are identified (i.e. parameters screening). Nevertheless, the choice of the screening threshold below which parameters are considered non-influential is a critical issue, which has recently received more attention in GSA literature. In theory, the sensitivity index of a non-influential parameter has a value of zero. However, since numerical approximations, rather than analytical solutions, are utilized in GSA methods to calculate the sensitivity indices, small but non-zero indices may be obtained for the indices of non-influential parameters. In order to assess the threshold that identifies non-influential parameters in GSA methods, we propose to calculate the sensitivity index of a "dummy parameter". This dummy parameter has no influence on the model output, but will have a non-zero sensitivity index, representing the error due to the numerical approximation. Hence, the parameters whose indices are above the sensitivity index of the dummy parameter can be classified as influential, whereas the parameters whose indices are below this index are within the range of the numerical error and should be considered as non-influential. To demonstrated the effectiveness of the proposed "dummy parameter approach", 26 parameters of a Soil and Water Assessment Tool (SWAT) model are selected to be analyzed and screened, using the variance-based Sobol' and moment-independent PAWN methods. The sensitivity index of the dummy parameter is calculated from sampled data, without changing the model equations. Moreover, the calculation does not even require additional model evaluations for the Sobol

  9. Using Scatterplots to Teach the Critical Power Concept

    ERIC Educational Resources Information Center

    Pettitt, Robert W.

    2012-01-01

    The critical power (CP) concept has received renewed attention and excitement in the academic community. The CP concept was originally conceived as a model derived from a series of exhaustive, constant-load, exercise bouts. All-out exercise testing has made quantification of the parameters for the two-component model easier to arrive at, which may…

  10. 40 CFR 86.001-22 - Approval of application for certification; test fleet selections; determinations of parameters...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... certification; test fleet selections; determinations of parameters subject to adjustment for certification and..., and for 1985 and Later Model Year New Gasoline Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas...; test fleet selections; determinations of parameters subject to adjustment for certification and...

  11. 40 CFR 86.001-22 - Approval of application for certification; test fleet selections; determinations of parameters...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... certification; test fleet selections; determinations of parameters subject to adjustment for certification and..., and for 1985 and Later Model Year New Gasoline Fueled, Natural Gas-Fueled, Liquefied Petroleum Gas...; test fleet selections; determinations of parameters subject to adjustment for certification and...

  12. Assessment of adrenocortical reserve capacity and inflammatory parameters in critically ill dogs.

    PubMed

    Csöndes, Judit; Fábián, Ibolya; Szabó, Bernadett; Máthé, Ákos; Vajdovich, Péter

    2017-12-01

    Inflammatory markers and adrenocorticotropic hormone (ACTH) stimulation test results may help us recognise critically ill dogs with poor disease outcome. Systemic inflammatory response syndrome (SIRS) criteria, the fast version of the Acute Patient Physiologic and Laboratory Evaluation Score (APPLE fast ), complete blood count, albumin and C-reactive protein (CRP) levels, baseline and stimulated cortisol levels and Δcortisol value were recorded in 50 client-owned dogs admitted to the Small Animal Hospital of the University of Veterinary Medicine Budapest with various inflammatory or neoplastic conditions. Increasing APPLE fast score was associated with a decreasing chance of survival (P = 0.0420). The Δcortisol value was significantly higher in SIRS dogs than in non-SIRS dogs (mean ± SD Δcortisol SIRS : 342.5 ± 273.96; mean ± SD Δcortisol non-SIRS : 175.3 ± 150.35; P = 0.0443). Elevated baseline or stimulated cortisol levels were associated with a higher chance of non-survival (P = 0.0135 and P = 0.0311, respectively). These data indicate that pathologically higher baseline and stimulated cortisol levels represent an exaggerated stress response in critically ill dogs, which is negatively associated with survival.

  13. Testing of Safety-Critical Software Embedded in an Artificial Heart

    NASA Astrophysics Data System (ADS)

    Cha, Sungdeok; Jeong, Sehun; Yoo, Junbeom; Kim, Young-Gab

    Software is being used more frequently to control medical devices such as artificial heart or robotic surgery system. While much of software safety issues in such systems are similar to other safety-critical systems (e.g., nuclear power plants), domain-specific properties may warrant development of customized techniques to demonstrate fitness of the system on patients. In this paper, we report results of a preliminary analysis done on software controlling a Hybrid Ventricular Assist Device (H-VAD) developed by Korea Artificial Organ Centre (KAOC). It is a state-of-the-art artificial heart which completed animal testing phase. We performed software testing in in-vitro experiments and animal experiments. An abnormal behaviour, never detected during extensive in-vitro analysis and animal testing, was found.

  14. Genetic parameters on Bali cattle progeny test population

    NASA Astrophysics Data System (ADS)

    Hariansyah, A. R.; Raharjo, A.; Zainuri, A.; Parwoto, Y.; Prasetiyo, D.; Prastowo, S.; Widyas, N.

    2018-03-01

    Bali cattle (Bos javanicus) is Indonesian indigenous cattle with having superior genetics potential on fitness traits in tropical environment and low feed quality. Bali Cattle Breeding Center Pulukan Indonesia conducted progeny test per annum in order to select bulls using offspring’s phenotype. This paper aimed to estimate the genetic parameters of yearling weight in Bali cattle progeny test populations and to observe the variation between periods in the above breeding center. Data were collected from the year of 2013 to 2014. There were four bulls (3 tests, 1 AI control) in 2013 and five bulls (4 tests, 1 AI) in 2014. Thirty breeding females were allocated per paddock per bull and allowed to mate naturally. In total 80 and 104 offspring’s records were obtained from 2013 and 2014 data, respectively. We built half-sib family model to estimate the additive genetic variance due to the sire and later estimate the breeding value (EBV) of each sire. Results showed that in 2013 the heritability (h2) for yearling weight was 0.19 while in 2014 was 0.79. In both years, tested bulls had higher EBV compared to the control bulls. The remarkable difference of heritability between years was due to the variations among bull candidates which might differ every year with regards to their origins. The fact that the EBV of tested bulls were higher than the control bulls gave us insight that despite the conservation policy and the continuous departure of Bali cattle bulls outside the Island, the population could still maintain its genetic quality.

  15. How to Measure Critical Health Competences: Development and Validation of the Critical Health Competence Test (CHC Test)

    ERIC Educational Resources Information Center

    Steckelberg, Anke; Hulfenhaus, Christian; Kasper, Jurgen; Rost, Jurgen; Muhlhauser, Ingrid

    2009-01-01

    Consumers' autonomy regarding health increasingly requires competences to critically appraise health information. Critical health literacy refers to the concept of evidence-based medicine. Instruments to measure these competences in curriculum evaluation and surveys are lacking. We aimed to develop and validate an instrument to measure critical…

  16. Analysis of the selected mechanical parameters of coating of filters protecting against hazardous infrared radiation.

    PubMed

    Gralewicz, Grzegorz; Owczarek, Grzegorz; Kubrak, Janusz

    2017-03-01

    This article presents a comparison of the test results of selected mechanical parameters (hardness, Young's modulus, critical force for delamination) for protective filters intended for eye protection against harmful infrared radiation. Filters with reflective metallic films were studied, as well as interference filters developed at the Central Institute for Labour Protection - National Research Institute (CIOP-PIB). The test results of the selected mechanical parameters were compared with the test results, conducted in accordance with a standardised method, of simulating filter surface destruction that occurs during use.

  17. On the critical parameters that regulate the deformation behaviour of tooth enamel.

    PubMed

    Xie, Zonghan; Swain, Michael; Munroe, Paul; Hoffman, Mark

    2008-06-01

    Tooth enamel is the hardest tissue in the human body with a complex hierarchical structure. Enamel hypomineralisation--a developmental defect--has been reported to cause a marked reduction in the mechanical properties of enamel and loss of dental function. We discover a distinctive difference in the inelastic deformation mechanism between sound and hypomineralised enamels that is apparently controlled by microstructural variation. For sound enamel, when subjected to mechanical forces the controlling deformation mechanism was distributed shearing within nanometre thick protein layer between its constituent mineral crystals; whereas for hypomineralised enamel microcracking and subsequent crack growth were more evident in its less densely packed microstructure. We develop a mechanical model that not only identifies the critical parameters, i.e., the thickness and shear properties of enamels, that regulate the mechanical behaviour of enamel, but also explains the degradation of hypomineralised enamel as manifested by its lower resistance to deformation and propensity for catastrophic failure. With support of experimental data, we conclude that for sound enamel an optimal microstructure has been developed that endows enamel with remarkable structural integrity for durable mechanical function.

  18. The development and validation of a test of science critical thinking for fifth graders.

    PubMed

    Mapeala, Ruslan; Siew, Nyet Moi

    2015-01-01

    The paper described the development and validation of the Test of Science Critical Thinking (TSCT) to measure the three critical thinking skill constructs: comparing and contrasting, sequencing, and identifying cause and effect. The initial TSCT consisted of 55 multiple choice test items, each of which required participants to select a correct response and a correct choice of critical thinking used for their response. Data were obtained from a purposive sampling of 30 fifth graders in a pilot study carried out in a primary school in Sabah, Malaysia. Students underwent the sessions of teaching and learning activities for 9 weeks using the Thinking Maps-aided Problem-Based Learning Module before they answered the TSCT test. Analyses were conducted to check on difficulty index (p) and discrimination index (d), internal consistency reliability, content validity, and face validity. Analysis of the test-retest reliability data was conducted separately for a group of fifth graders with similar ability. Findings of the pilot study showed that out of initial 55 administered items, only 30 items with relatively good difficulty index (p) ranged from 0.40 to 0.60 and with good discrimination index (d) ranged within 0.20-1.00 were selected. The Kuder-Richardson reliability value was found to be appropriate and relatively high with 0.70, 0.73 and 0.92 for identifying cause and effect, sequencing, and comparing and contrasting respectively. The content validity index obtained from three expert judgments equalled or exceeded 0.95. In addition, test-retest reliability showed good, statistically significant correlations ([Formula: see text]). From the above results, the selected 30-item TSCT was found to have sufficient reliability and validity and would therefore represent a useful tool for measuring critical thinking ability among fifth graders in primary science.

  19. Spacecraft System Integration and Test: SSTI Lewis critical design audit

    NASA Technical Reports Server (NTRS)

    Brooks, R. P.; Cha, K. K.

    1995-01-01

    The Critical Design Audit package is the final detailed design package which provides a comprehensive description of the SSTI mission. This package includes the program overview, the system requirements, the science and applications activities, the ground segment development, the assembly, integration and test description, the payload and technology demonstrations, and the spacecraft bus subsystems. Publication and presentation of this document marks the final requirements and design freeze for SSTI.

  20. Integrated system for remotely monitoring critical physiological parameters

    NASA Astrophysics Data System (ADS)

    Alexakis, S.; Karalis, S.; Asvestas, P.

    2015-09-01

    Monitoring several human parameters (temperature, heart rate, blood pressure etc.) is an essential task in health care in hospitals as well as in home care. This paper presents the design and implementation of an integrated, embedded system that includes an electrocardiograph of nine leads and two channels, a digital thermometer for measuring the body temperature and a power supply. The system provides networking capabilities (wired or wireless) and is accessible by means of a web interface that allows the user to select the leads, as well as to review the values of heart rate (beats per minute) and body temperature. Furthermore, there is the option of saving all the data in a Micro SD memory card or in a Google Spreadsheet. The necessary analog circuits for signal conditioning (amplification and filtering) were manufactured on printed circuit boards (PCB). The system was built around Arduino Yun, which is a platform that contains a microcontroller and a microprocessor running a special LINUX distribution. Furthermore, the Arduino Yun provides the necessary network connectivity capabilities by means of the integrated Wi-Fi and Ethernet interfaces. The web interface was developed using HTML pages with JavaScript support. The system was tested on simulated data as well as real data, providing satisfactory accuracy regarding the measurement of the heart rate (±3 bpm error) and the temperature (±0.3°C error).

  1. The Critical Compression Load for a Universal Testing Machine When the Specimen Is Loaded Through Knife Edges

    NASA Technical Reports Server (NTRS)

    Lundquist, Eugene E; Schwartz, Edward B

    1942-01-01

    The results of a theoretical and experimental investigation to determine the critical compression load for a universal testing machine are presented for specimens loaded through knife edges. The critical load for the testing machine is the load at which one of the loading heads becomes laterally instable in relation to the other. For very short specimens the critical load was found to be less than the rated capacity given by the manufacturer for the machine. A load-length diagram is proposed for defining the safe limits of the test region for the machine. Although this report is particularly concerned with a universal testing machine of a certain type, the basic theory which led to the derivation of the general equation for the critical load, P (sub cr) = alpha L can be applied to any testing machine operated in compression where the specimen is loaded through knife edges. In this equation, L is the length of the specimen between knife edges and alpha is the force necessary to displace the upper end of the specimen unit horizontal distance relative to the lower end of the specimen in a direction normal to the knife edges through which the specimen is loaded.

  2. Solventless visible light-curable coating: I. Critical formulation and processing parameters.

    PubMed

    Bose, Sagarika; Bogner, Robin H

    2010-06-30

    Film coating is generally accomplished by spraying polymers dissolved in solvents onto a cascading bed of tablets. The limitations associated with the use of solvents (both aqueous and organic) can be overcome by the use of solventless coating technologies. In this proposed solventless photocurable film coating system, each layer of coating onto the pellets (non-pareil beads) was formed using liquid photocurable monomer, powdered pore-forming agents, photosensitizers and photoinitiators in a mini-coating pan and later cured by visible light. Yield, coating efficiency, variation in color, diameter and roundness were determined for each batch to evaluate process efficiency and coating quality. It was found that the ratio (S/L ratio) of the amount of solid (S) pore-forming agent to volume of liquid (L) monomer, particle size and type of the pore-forming agent, concentration of initiator, and total exposure (light intensity x exposure time) of light were critical formulation and processing parameters for the process. Using lactose as a pore-forming agent, an optimum ratio of pore-forming agent to photocurable polymer was 1.8-3.0 to achieve good process efficiency and uniformity. The ratio was sensitive to particle size and type of pore-forming agent. 2010 Elsevier B.V. All rights reserved.

  3. Assessing a Critical Aspect of Construct Continuity when Test Specifications Change or Test Forms Deviate from Specifications

    ERIC Educational Resources Information Center

    Liu, Jinghua; Dorans, Neil J.

    2013-01-01

    We make a distinction between two types of test changes: inevitable deviations from specifications versus planned modifications of specifications. We describe how score equity assessment (SEA) can be used as a tool to assess a critical aspect of construct continuity, the equivalence of scores, whenever planned changes are introduced to testing…

  4. Validation of Slosh Model Parameters and Anti-Slosh Baffle Designs of Propellant Tanks by Using Lateral Slosh Testing

    NASA Technical Reports Server (NTRS)

    Perez, Jose G.; Parks, Russel A.; Lazor, Daniel R.

    2012-01-01

    The slosh dynamics of propellant tanks can be represented by an equivalent pendulum-mass mechanical model. The parameters of this equivalent model, identified as slosh model parameters, are slosh mass, slosh mass center of gravity, slosh frequency, and smooth-wall damping. They can be obtained by both analysis and testing for discrete fill heights. Anti-slosh baffles are usually needed in propellant tanks to control the movement of the fluid inside the tank. Lateral slosh testing, involving both random testing and free-decay testing, are performed to validate the slosh model parameters and the damping added to the fluid by the anti-slosh baffles. Traditional modal analysis procedures are used to extract the parameters from the experimental data. Test setup of sub-scale test articles of cylindrical and spherical shapes will be described. A comparison between experimental results and analysis will be presented.

  5. Free-piston Stirling engine/linear alternator 1000-hour endurance test

    NASA Technical Reports Server (NTRS)

    Rauch, J.; Dochat, G.

    1985-01-01

    The Free Piston Stirling Engine (FPSE) has the potential to be a long lived, highly reliable, power conversion device attractive for many product applications such as space, residential or remote site power. The purpose of endurance testing the FPSE was to demonstrate its potential for long life. The endurance program was directed at obtaining 1000 operational hours under various test conditions: low power, full stroke, duty cycle and stop/start. Critical performance parameters were measured to note any change and/or trend. Inspections were conducted to measure and compare critical seal/bearing clearances. The engine performed well throughout the program, completing more than 1100 hours. Hardware inspection, including the critical clearances, showed no significant change in hardware or clearance dimensions. The performance parameters did not exhibit any increasing or decreasing trends. The test program confirms the potential for long life FPSE applications.

  6. Determination of a quantitative parameter to evaluate swimming technique based on the maximal tethered swimming test.

    PubMed

    Soncin, Rafael; Mezêncio, Bruno; Ferreira, Jacielle Carolina; Rodrigues, Sara Andrade; Huebner, Rudolf; Serrão, Julio Cerca; Szmuchrowski, Leszek

    2017-06-01

    The aim of this study was to propose a new force parameter, associated with swimmers' technique and performance. Twelve swimmers performed five repetitions of 25 m sprint crawl and a tethered swimming test with maximal effort. The parameters calculated were: the mean swimming velocity for crawl sprint, the mean propulsive force of the tethered swimming test as well as an oscillation parameter calculated from force fluctuation. The oscillation parameter evaluates the force variation around the mean force during the tethered test as a measure of swimming technique. Two parameters showed significant correlations with swimming velocity: the mean force during the tethered swimming (r = 0.85) and the product of the mean force square root and the oscillation (r = 0.86). However, the intercept coefficient was significantly different from zero only for the mean force, suggesting that although the correlation coefficient of the parameters was similar, part of the mean velocity magnitude that was not associated with the mean force was associated with the product of the mean force square root and the oscillation. Thus, force fluctuation during tethered swimming can be used as a quantitative index of swimmers' technique.

  7. Critical Thinking in Adulthood.

    ERIC Educational Resources Information Center

    Fulton, Rodney D.

    Critical thinking is often defined as that which a particular instrument measures. The most prominent tests are the Watson-Glaser Critical Thinking Appraisal, the Ennis-Weir Critical Thinking Essay Test, and the Cornell Critical Thinking Tests. Watson and Glaser's (1980) view of critical thinking is "a composite of attitudes, knowledge, and…

  8. HIGH-SHEAR GRANULATION PROCESS: INFLUENCE OF PROCESSING PARAMETERS ON CRITICAL QUALITY ATTRIBUTES OF ACETAMINOPHEN GRANULES AND TABLETS USING DESIGN OF EXPERIMENT APPROACH.

    PubMed

    Fayed, Mohamed H; Abdel-Rahman, Sayed I; Alanazi, Fars K; Ahmed, Mahrous O; Tawfeek, Hesham M; Al-Shedfat, Ramadan I

    2017-01-01

    Application of quality by design (QbD) in high shear granulation process is critical and need to recognize the correlation between the granulation process parameters and the properties of intermediate (granules) and corresponding final product (tablets). The present work examined the influence of water amount (X,) and wet massing time (X2) as independent process variables on the critical quality attributes of granules and corresponding tablets using design of experiment (DoE) technique. A two factor, three level (32) full factorial design was performed; each of these variables was investigated at three levels to characterize their strength and interaction. The dried granules have been analyzed for their size distribution, density and flow pattern. Additionally, the produced tablets have been investigated for weight uniformity, crushing strength, friability and percent capping, disintegration time and drug dissolution. Statistically significant impact (p < 0.05) of water amount was identified for granule growth, percent fines and distribution width and flow behavior. Granule density and compressibility were found to be significantly influenced (p < 0.05) by the two operating conditions. Also, water amount has significant effect (p < 0.05) on tablet weight unifornity, friability and percent capping. Moreover, tablet disintegration time and drug dissolution appears to be significantly influenced (p < 0.05) by the two process variables. On the other hand, the relationship of process parameters with critical quality attributes of granule and final product tablet was identified and correlated. Ultimately, a judicious selection of process parameters in high shear granulation process will allow providing product of desirable quality.

  9. Critical and post-critical behaviour of two-degree-of-freedom flutter-based generators

    NASA Astrophysics Data System (ADS)

    Pigolotti, Luca; Mannini, Claudio; Bartoli, Gianni; Thiele, Klaus

    2017-09-01

    Energy harvesting from flow-induced vibrations is a recent research field, which considers a diverse range of systems, among which two-degree-of-freedom flutter-based solutions were individuated as good candidates to obtain high energy performance. In the present work, numerical linear analyses and wind-tunnel tests were conducted on a flat-plate sectional model. The aim is to identify some design guidelines for generators exploiting the classical-flutter instability, through the investigation of the critical condition and the response during the post-critical regime. Many sets of governing parameters of interest from the energy-harvesting point of view were considered, including high levels of heaving damping to simulate the operation of a conversion apparatus. In particular, eccentricity of the elastic centre and small downstream mass unbalance can be introduced as solutions aiming at optimal operative ranges. The collected results suggest the high potentiality of flutter-based generators, and a significant enhancement of performance can be envisaged. Moreover, they contribute to improve the knowledge of the flutter excitation mechanism and to widen the dataset of measurements in the post-critical regime.

  10. Changes of peritoneal transport parameters with time on dialysis: assessment with sequential peritoneal equilibration test.

    PubMed

    Waniewski, Jacek; Antosiewicz, Stefan; Baczynski, Daniel; Poleszczuk, Jan; Pietribiasi, Mauro; Lindholm, Bengt; Wankowicz, Zofia

    2017-10-27

    Sequential peritoneal equilibration test (sPET) is based on the consecutive performance of the peritoneal equilibration test (PET, 4-hour, glucose 2.27%) and the mini-PET (1-hour, glucose 3.86%), and the estimation of peritoneal transport parameters with the 2-pore model. It enables the assessment of the functional transport barrier for fluid and small solutes. The objective of this study was to check whether the estimated model parameters can serve as better and earlier indicators of the changes in the peritoneal transport characteristics than directly measured transport indices that depend on several transport processes. 17 patients were examined using sPET twice with the interval of about 8 months (230 ± 60 days). There was no difference between the observational parameters measured in the 2 examinations. The indices for solute transport, but not net UF, were well correlated between the examinations. Among the estimated parameters, a significant decrease between the 2 examinations was found only for hydraulic permeability LpS, and osmotic conductance for glucose, whereas the other parameters remained unchanged. These fluid transport parameters did not correlate with D/P for creatinine, although the decrease in LpS values between the examinations was observed mostly for patients with low D/P for creatinine. We conclude that changes in fluid transport parameters, hydraulic permeability and osmotic conductance for glucose, as assessed by the pore model, may precede the changes in small solute transport. The systematic assessment of fluid transport status needs specific clinical and mathematical tools beside the standard PET tests.

  11. Critical issues with the in vivo comet assay: A report of the comet assay working group in the 6th International Workshop on Genotoxicity Testing (IWGT).

    PubMed

    Speit, Günter; Kojima, Hajime; Burlinson, Brian; Collins, Andrew R; Kasper, Peter; Plappert-Helbig, Ulla; Uno, Yoshifumi; Vasquez, Marie; Beevers, Carol; De Boeck, Marlies; Escobar, Patricia A; Kitamoto, Sachiko; Pant, Kamala; Pfuhler, Stefan; Tanaka, Jin; Levy, Dan D

    2015-05-01

    As a part of the 6th IWGT, an expert working group on the comet assay evaluated critical topics related to the use of the in vivo comet assay in regulatory genotoxicity testing. The areas covered were: identification of the domain of applicability and regulatory acceptance, identification of critical parameters of the protocol and attempts to standardize the assay, experience with combination and integration with other in vivo studies, demonstration of laboratory proficiency, sensitivity and power of the protocol used, use of different tissues, freezing of samples, and choice of appropriate measures of cytotoxicity. The standard protocol detects various types of DNA lesions but it does not detect all types of DNA damage. Modifications of the standard protocol may be used to detect additional types of specific DNA damage (e.g., cross-links, bulky adducts, oxidized bases). In addition, the working group identified critical parameters that should be carefully controlled and described in detail in every published study protocol. In vivo comet assay results are more reliable if they were obtained in laboratories that have demonstrated proficiency. This includes demonstration of adequate response to vehicle controls and an adequate response to a positive control for each tissue being examined. There was a general agreement that freezing of samples is an option but more data are needed in order to establish generally accepted protocols. With regard to tissue toxicity, the working group concluded that cytotoxicity could be a confounder of comet results. It is recommended to look at multiple parameters such as histopathological observations, organ-specific clinical chemistry as well as indicators of tissue inflammation to decide whether compound-specific toxicity might influence the result. The expert working group concluded that the alkaline in vivo comet assay is a mature test for the evaluation of genotoxicity and can be recommended to regulatory agencies for use

  12. A new critical dimension metrology for chrome-on-glass substrates based on s-parameter measurements extracted from coplanar waveguide test structures

    NASA Astrophysics Data System (ADS)

    Nwokoye, Chidubem A.; Zaghloul, Mona; Cresswell, Michael W.; Allen, Richard A.; Murabito, Christine E.

    2006-10-01

    The technical objective of the work reported here is to assess whether radio-frequency (RF) measurements made on coplanar waveguide (CPW) test structures, which are replicated in conducting material on insulating substrates, could be employed to extract the critical dimension (CD) of the signal line using its center-to-center separation from the groundlines as a reference. The specific near-term objective is to assess whether this CPW-based CD-metrology has sensitivity and repeatability competitive with the other metrology techniques that are now used for chrome-on-glass (COG) photomasks. An affirmative answer is encouraging because advancing to a non-contact and non-vacuum implementation would then seem possible for this application. Our modeling of specific cases shows that, when the pitch of the replicated lines of the CPW is maintained constant, the sensitivity of its characteristic impedance to the CDs of the signal and ground lines is approximately 60 Ω/μm. This is a potentially useful result. For the same implementation, the quantity ∂C/∂w has a value of approximately 45 (pF/m)/μm, which appears to be large enough to provide acceptable accuracy.

  13. Effect of Explosion Bulge Test Parameters on the Measurement of Deformation Resistance for Steel

    DTIC Science & Technology

    2014-02-01

    UNCLASSIFIED UNCLASSIFIED Effect of Explosion Bulge Test Parameters on the Measurement of Deformation Resistance for Steel C...Measurement of Deformation Resistance for Steel Executive Summary The Explosion Bulge Test has been used for over 60 years as a standard test for...the assessment of steel toughness and deformation resistance under blast loading conditions [1-3]. However, details of the test conditions vary

  14. Validation of Slosh Model Parameters and Anti-Slosh Baffle Designs of Propellant Tanks by Using Lateral Slosh Testing

    NASA Technical Reports Server (NTRS)

    Perez, Jose G.; Parks, Russel, A.; Lazor, Daniel R.

    2012-01-01

    The slosh dynamics of propellant tanks can be represented by an equivalent mass-pendulum-dashpot mechanical model. The parameters of this equivalent model, identified as slosh mechanical model parameters, are slosh frequency, slosh mass, and pendulum hinge point location. They can be obtained by both analysis and testing for discrete fill levels. Anti-slosh baffles are usually needed in propellant tanks to control the movement of the fluid inside the tank. Lateral slosh testing, involving both random excitation testing and free-decay testing, are performed to validate the slosh mechanical model parameters and the damping added to the fluid by the anti-slosh baffles. Traditional modal analysis procedures were used to extract the parameters from the experimental data. Test setup of sub-scale tanks will be described. A comparison between experimental results and analysis will be presented.

  15. The development and testing of a qualitative instrument designed to assess critical thinking

    NASA Astrophysics Data System (ADS)

    Clauson, Cynthia Louisa

    This study examined a qualitative approach to assess critical thinking. An instrument was developed that incorporates an assessment process based on Dewey's (1933) concepts of self-reflection and critical thinking as problem solving. The study was designed to pilot test the critical thinking assessment process with writing samples collected from a heterogeneous group of students. The pilot test included two phases. Phase 1 was designed to determine the validity and inter-rater reliability of the instrument using two experts in critical thinking, problem solving, and literacy development. Validity of the instrument was addressed by requesting both experts to respond to ten questions in an interview. The inter-rater reliability was assessed by analyzing the consistency of the two experts' scorings of the 20 writing samples to each other, as well as to my scoring of the same 20 writing samples. Statistical analyses included the Spearman Rho and the Kuder-Richardson (Formula 20). Phase 2 was designed to determine the validity and reliability of the critical thinking assessment process with seven science teachers. Validity was addressed by requesting the teachers to respond to ten questions in a survey and interview. Inter-rater reliability was addressed by comparing the seven teachers' scoring of five writing samples with my scoring of the same five writing samples. Again, the Spearman Rho and the Kuder-Richardson (Formula 20) were used to determine the inter-rater reliability. The validity results suggest that the instrument is helpful as a guide for instruction and provides a systematic method to teach and assess critical thinking while problem solving with students in the classroom. The reliability results show the critical thinking assessment instrument to possess fairly high reliability when used by the experts, but weak reliability when used by classroom teachers. A major conclusion was drawn that teachers, as well as students, would need to receive instruction

  16. Alterations in rotation thromboelastometry (ROTEM®) parameters: point-of-care testing vs analysis after pneumatic tube system transport.

    PubMed

    Martin, J; Schuster, T; Moessmer, G; Kochs, E F; Wagner, K J

    2012-10-01

    Thromboelastometry as point-of-care (POC) testing enables the analysis of the clotting process at the bedside, providing rapid results to guide haemostatic therapy. However, POC testing utilizes medical staff who are managing critically ill patients, as non-laboratory personnel may not be sufficiently trained to run the devices. To resolve these problems, thromboelastometry can be performed in the central laboratory and rapid transport of samples can be accomplished via a pneumatic tube system (PTS). This study compares thromboelastometry parameters of blood samples analysed immediately with those analysed after PTS transport. In patients with normal haemostasis, two arterial blood samples were collected from each patient (n=92) in citrated plastic tubes to investigate the assays INTEM (n=35), EXTEM (n=27), and FIBTEM (n=30). One blood sample was analysed immediately, the other sample after PTS transport. Thromboelastometry was performed using a single ROTEM(®) device. The mean clot firmness values were significantly lower for PTS samples in both the INTEM (-0.7 mm cf. -1.1 mm) and EXTEM (-1.4 cf. -1.7 mm) assays. INTEM coagulation time (CT) was significantly lower in PTS samples with a mean difference of -13 s. EXTEM CT was significantly higher in PTS samples with a mean difference of +3.9 s. Thromboelastometry parameters of blood samples analysed after PTS transport are significantly altered compared with those analysed immediately. However, in patients with normal haemostasis, the alterations were small and without clinical consequence, implying that analysis after PTS transport is an acceptable alternative to prompt analysis at the bedside. Further studies should focus on patients with impaired haemostasis.

  17. Sequential Testing of Hypotheses Concerning the Reliability of a System Modeled by a Two-Parameter Weibull Distribution.

    DTIC Science & Technology

    1981-12-01

    CONCERNING THE RELIABILITY OF A SYSTEM MODELED BY A TWO-PARAMETER WEIBULL DISTRIBUTION THESIS AFIT/GOR/MA/81D-8 Philippe A. Lussier 2nd Lt USAF... MODELED BY A TWO-PARAMETER WEIBULL DISTRIBUTION THESIS Presented to the Faculty of the School of Engineering of the Air Force Institute of Technology...repetitions are used for these test procedures. vi Sequential Testing of Hypotheses Concerning the Reliability of a System Modeled by a Two-Parameter

  18. Systematic parameter estimation and sensitivity analysis using a multidimensional PEMFC model coupled with DAKOTA.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chao Yang; Luo, Gang; Jiang, Fangming

    2010-05-01

    Current computational models for proton exchange membrane fuel cells (PEMFCs) include a large number of parameters such as boundary conditions, material properties, and numerous parameters used in sub-models for membrane transport, two-phase flow and electrochemistry. In order to successfully use a computational PEMFC model in design and optimization, it is important to identify critical parameters under a wide variety of operating conditions, such as relative humidity, current load, temperature, etc. Moreover, when experimental data is available in the form of polarization curves or local distribution of current and reactant/product species (e.g., O2, H2O concentrations), critical parameters can be estimated inmore » order to enable the model to better fit the data. Sensitivity analysis and parameter estimation are typically performed using manual adjustment of parameters, which is also common in parameter studies. We present work to demonstrate a systematic approach based on using a widely available toolkit developed at Sandia called DAKOTA that supports many kinds of design studies, such as sensitivity analysis as well as optimization and uncertainty quantification. In the present work, we couple a multidimensional PEMFC model (which is being developed, tested and later validated in a joint effort by a team from Penn State Univ. and Sandia National Laboratories) with DAKOTA through the mapping of model parameters to system responses. Using this interface, we demonstrate the efficiency of performing simple parameter studies as well as identifying critical parameters using sensitivity analysis. Finally, we show examples of optimization and parameter estimation using the automated capability in DAKOTA.« less

  19. Critical assessment of jet erosion test methodologies for cohesive soil and sediment

    USDA-ARS?s Scientific Manuscript database

    The submerged Jet Erosion Test (JET) is a commonly used technique to assess the erodibility of cohesive soil. Employing a linear excess shear stress equation and impinging jet theory, simple numerical methods have been developed to analyze data collected using a JET to determine the critical shear s...

  20. Critical Review of the ECSS-E-ST-20-07C ESD Test Set-Up for Testing Spacecraft Equipment

    NASA Astrophysics Data System (ADS)

    Pelissou, P.; Daout, B.; Romero, C.; Wolf, K.-F. J.

    2016-05-01

    Satellite equipment needs to be immune to electrostatic discharges (ESD) likely to occur in flight. Testing the susceptibility against ESD on spacecraft equipment is therefore an important part of the EMC test program. The test method according to ECSS-E-ST- 20-07C [1], which is commonly used in space industry, leaves undesirable degrees of freedom on how the test is performed, which in turn has an influence on the injected current and therefore on the test results. Because of the indirect coupling of ESD to circuits, the current waveform applied during the test and its repeatability are of high importance. In the frame of an ESTEC research contract (4000109887/13/NL/GLC), a critical review of the ECSS-E-ST-20-07C is performed to identify the influence factors which have an impact on the test repeatability.

  1. Analysis of Acoustic Emission Parameters from Corrosion of AST Bottom Plate in Field Testing

    NASA Astrophysics Data System (ADS)

    Jomdecha, C.; Jirarungsatian, C.; Suwansin, W.

    Field testing of aboveground storage tank (AST) to monitor corrosion of the bottom plate is presented in this chapter. AE testing data of the ten AST with different sizes, materials, and products were employed to monitor the bottom plate condition. AE sensors of 30 and 150 kHz were used to monitor the corrosion activity of up to 24 channels including guard sensors. Acoustic emission (AE) parameters were analyzed to explore the AE parameter patterns of occurring corrosion compared to the laboratory results. Amplitude, count, duration, and energy were main parameters of analysis. Pattern recognition technique with statistical was implemented to eliminate the electrical and environmental noises. The results showed the specific AE patterns of corrosion activities related to the empirical results. In addition, plane algorithm was utilized to locate the significant AE events from corrosion. Both results of parameter patterns and AE event locations can be used to interpret and locate the corrosion activities. Finally, basic statistical grading technique was used to evaluate the bottom plate condition of the AST.

  2. Lumped Parameter Modeling for Rapid Vibration Response Prototyping and Test Correlation for Electronic Units

    NASA Technical Reports Server (NTRS)

    Van Dyke, Michael B.

    2013-01-01

    Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.

  3. Profile of Students’ Critical Thinking Skill Measured by Science Virtual Test on Living Things and Environmental Sustainability Theme

    NASA Astrophysics Data System (ADS)

    Maulida, N. I.; Firman, H.; Rusyati, L.

    2017-02-01

    The aims of this study are: (1) to investigate the level of students’ critical thinking skill on living things and environmental sustainability theme for each Inch’ critical thinking elements and overall, (2) to investigate the level of students’ critical thinking skill on living things characteristic, biodiversity, energy resources, ecosystem, environmental pollution, and global warming topics. The research was conducted due to the important of critical thinking measurement to get the current skill description as the basic consideration for further critical thinking skill improvement in lower secondary science. The research method used was descriptive. 331 seventh grade students taken from five lower secondary schools in Cirebon were tested to get the critical thinking skill data by using Science Virtual Test as the instrument. Generally, the mean scores on eight Inch’ critical thinking elements and overall score from descriptive statistic reveals a moderate attainments level. Students’ critical thinking skill on biodiversity, energy resources, ecosystem, environmental pollution, and global warming topics are in moderate level. While students’ critical thinking skill on living things characteristic is identified as high level. Students’ experience in thinking critically during science learning process and the characteristic of the topic are emerged as the reason behind the students’ critical thinking skill level on certain science topic.

  4. An Examination of Two Procedures for Identifying Consequential Item Parameter Drift

    ERIC Educational Resources Information Center

    Wells, Craig S.; Hambleton, Ronald K.; Kirkpatrick, Robert; Meng, Yu

    2014-01-01

    The purpose of the present study was to develop and evaluate two procedures flagging consequential item parameter drift (IPD) in an operational testing program. The first procedure was based on flagging items that exhibit a meaningful magnitude of IPD using a critical value that was defined to represent barely tolerable IPD. The second procedure…

  5. A Modified Cramer-von Mises and Anderson-Darling Test for the Weibull Distribution with Unknown Location and Scale Parameters.

    DTIC Science & Technology

    1981-12-01

    preventing the generation of 16 6 negative location estimators. Because of the invariant pro- perty of the EDF statistics, this transformation will...likelihood. If the parameter estimation method developed by Harter and Moore is used, care must be taken to prevent the location estimators from being...vs A 2 Critical Values, Level-.Ol, n-30 128 , 0 6N m m • w - APPENDIX E Computer Prgrams 129 Program to Calculate the Cramer-von Mises Critical Values

  6. Defining and Developing "Critical Thinking" Through Devising and Testing Multiple Explanations of the Same Phenomenon

    NASA Astrophysics Data System (ADS)

    Etkina, Eugenia; Planinšič, Gorazd

    2015-10-01

    Most physics teachers would agree that one of the main reasons for her/his students to take physics is to learn to think critically. However, for years we have been assessing our students mostly on the knowledge of physics content (conceptually and quantitatively). Only recently have science educators started moving systematically towards achieving and assessing this critical thinking goal. In this paper we seek to show how guiding students to devise and test multiple explanations of observed phenomena can be used to improve their critical thinking.

  7. New post-Newtonian parameter to test Chern-Simons gravity.

    PubMed

    Alexander, Stephon; Yunes, Nicolas

    2007-12-14

    We study Chern-Simons (CS) gravity in the parametrized post-Newtonian (PPN) framework through a weak-field solution of the modified field equations. We find that CS gravity possesses the same PPN parameters as general relativity, except for the inclusion of a new term, proportional to the CS coupling and the curl of the PPN vector potential. This new term leads to a modification of frame dragging and gyroscopic precession and we provide an estimate of its size. This correction might be used in experiments, such as Gravity Probe B, to bound CS gravity and test string theory.

  8. Parameters estimation for reactive transport: A way to test the validity of a reactive model

    NASA Astrophysics Data System (ADS)

    Aggarwal, Mohit; Cheikh Anta Ndiaye, Mame; Carrayrou, Jérôme

    The chemical parameters used in reactive transport models are not known accurately due to the complexity and the heterogeneous conditions of a real domain. We will present an efficient algorithm in order to estimate the chemical parameters using Monte-Carlo method. Monte-Carlo methods are very robust for the optimisation of the highly non-linear mathematical model describing reactive transport. Reactive transport of tributyltin (TBT) through natural quartz sand at seven different pHs is taken as the test case. Our algorithm will be used to estimate the chemical parameters of the sorption of TBT onto the natural quartz sand. By testing and comparing three models of surface complexation, we show that the proposed adsorption model cannot explain the experimental data.

  9. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    PubMed

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  10. Periodontal parameters and BANA test in patients with chronic renal failure undergoing hemodialysis

    PubMed Central

    TORRES, Sérgio Aparecido; ROSA, Odila Pereira da Silva; HAYACIBARA, Mitsue Fujimaki; GUIMARÃES, Maria do Carmo Machado; HAYACIBARA, Roberto M.; BRETZ, Walter Antônio

    2010-01-01

    Objectives The aim of this study was to analyze the periodontal parameters of patients with chronic renal failure. Material and Methods The periodontal status of 16 Brazilian patients aged 29 to 53 (41.7±7.2) years with chronic renal failure (CRF) and another matched group of 14 healthy controls with periodontitis was assessed clinically and microbiologically. Probing pocket depth (PPD), gingival recession (GR), dental plaque index (PLI), gingival index (GI), and dental calculus index (CI) were the clinical parameters recorded for the entire dentition (at least 19 teeth), while the anaerobic periodontopathogen colonization in four sites with the highest PPD was evaluated using the BANA test (“PerioScan”; Oral B). Results The results for the CRF group and control group, respectively were: PPD: 1.77±0.32 and 2.65±0.53; GR: 0.58±0.56 and 0.51±0.36; PLI: 1.64±0.56 and 1.24±0.67; GI: 0.64±0.42 and 0.93±0.50; CI: 1.17±0.54 and 0.87±0.52. Comparison between groups using the "t" test revealed a significantly increased PPD (p<0.001) in the control group. Comparison of the other clincial parameters by the Mann-Whitney test showed differences only for PLI, which was significantly higher (p<0.05) in the CRF group. Spearman's test applied to each group showed a positive correlation among all clinical parameters, except for GR (p<0.05). None of the groups showed any correlation between GR and GI, while a significant negative correlation between GR and PPD was observed for the CRF group. The percentage of BANA-positive sites was 35.9% for the CRF group and 35.7% for the control group. The BANA test correlated positively with PPD only in the control group and with GR only in the CRF group. Conclusions In spite of a higher PLI and dense anaerobic microbial population even in shallow PPD, patients with CRF exhibited better periodontal conditions than periodontitis patients, which is an evidence of altered response to local irritants. PMID:20857011

  11. Development and psychometric testing of the Carter Assessment of Critical Thinking in Midwifery (Preceptor/Mentor version).

    PubMed

    Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary

    2016-03-01

    develop and test a tool designed for use by preceptors/mentors to assess undergraduate midwifery students׳ critical thinking in practice. a descriptive cohort design was used. participants worked in a range of maternity settings in Queensland, Australia. 106 midwifery clinicians who had acted in the role of preceptor for undergraduate midwifery students. this study followed a staged model for tool development recommended by DeVellis (2012). This included generation of items, content validity testing through mapping of draft items to critical thinking concepts and expert review, administration of items to a convenience sample of preceptors, and psychometric testing. A 24 item tool titled the XXXX Assessment of Critical Thinking in Midwifery (CACTiM) was completed by registered midwives in relation to students they had recently preceptored in the clinical environment. ratings by experts revealed a content validity index score of 0.97, representing good content validity. An evaluation of construct validity through factor analysis generated three factors: 'partnership in practice', 'reflection on practice' and 'practice improvements'. The scale demonstrated good internal reliability with a Cronbach alpha coefficient of 0.97. The mean total score for the CACTiM scale was 116.77 (SD=16.68) with a range of 60-144. Total and subscale scores correlated significantly. the CACTiM (Preceptor/Mentor version) was found to be a valid and reliable tool for use by preceptors to assess critical thinking in undergraduate midwifery students. given the importance of critical thinking skills for midwifery practice, mapping and assessing critical thinking development in students׳ practice across an undergraduate programme is vital. The CACTiM (Preceptor/Mentor version) has utility for clinical education, research and practice. The tool can inform and guide preceptors׳ assessment of students׳ critical thinking in practice. The availability of a reliable and valid tool can be used to

  12. Experimental and computational correlation of fracture parameters KIc, JIc, and GIc for unimodular and bimodular graphite components

    NASA Astrophysics Data System (ADS)

    Bhushan, Awani; Panda, S. K.

    2018-05-01

    The influence of bimodularity (different stress ∼ strain behaviour in tension and compression) on fracture behaviour of graphite specimens has been studied with fracture toughness (KIc), critical J-integral (JIc) and critical strain energy release rate (GIc) as the characterizing parameter. Bimodularity index (ratio of tensile Young's modulus to compression Young's modulus) of graphite specimens has been obtained from the normalized test data of tensile and compression experimentation. Single edge notch bend (SENB) testing of pre-cracked specimens from the same lot have been carried out as per ASTM standard D7779-11 to determine the peak load and critical fracture parameters KIc, GIc and JIc using digital image correlation technology of crack opening displacements. Weibull weakest link theory has been used to evaluate the mean peak load, Weibull modulus and goodness of fit employing two parameter least square method (LIN2), biased (MLE2-B) and unbiased (MLE2-U) maximum likelihood estimator. The stress dependent elasticity problem of three-dimensional crack progression behaviour for the bimodular graphite components has been solved as an iterative finite element procedure. The crack characterizing parameters critical stress intensity factor and critical strain energy release rate have been estimated with the help of Weibull distribution plot between peak loads versus cumulative probability of failure. Experimental and Computational fracture parameters have been compared qualitatively to describe the significance of bimodularity. The bimodular influence on fracture behaviour of SENB graphite has been reflected on the experimental evaluation of GIc values only, which has been found to be different from the calculated JIc values. Numerical evaluation of bimodular 3D J-integral value is found to be close to the GIc value whereas the unimodular 3D J-value is nearer to the JIc value. The significant difference between the unimodular JIc and bimodular GIc indicates that

  13. The Effects of Test Length and Sample Size on Item Parameters in Item Response Theory

    ERIC Educational Resources Information Center

    Sahin, Alper; Anil, Duygu

    2017-01-01

    This study investigates the effects of sample size and test length on item-parameter estimation in test development utilizing three unidimensional dichotomous models of item response theory (IRT). For this purpose, a real language test comprised of 50 items was administered to 6,288 students. Data from this test was used to obtain data sets of…

  14. Criticality in epidemiology

    NASA Astrophysics Data System (ADS)

    Stollenwerk, Nico; Jansen, Vincent A. A.

    For a long time criticality has been considered in epidemiological models. We review the body of theory developed over the last twenty five years for the simplest models. It is at first glance difficult to imagine that an epidemiological system operates at a very fine tuned critical state as opposed to any other parameter region. However, the advent of self-organized criticality has given hints in how to interpret large fluctuations observed in many natural systems including epidemiological systems. We show some scenarios where criticality has been observed (e.g., measles under vaccination) and where evolution towards a critical state can explain fluctuations (e.g., meningococcal disease.)

  15. A parameter estimation algorithm for spatial sine testing - Theory and evaluation

    NASA Technical Reports Server (NTRS)

    Rost, R. W.; Deblauwe, F.

    1992-01-01

    This paper presents the theory and an evaluation of a spatial sine testing parameter estimation algorithm that uses directly the measured forced mode of vibration and the measured force vector. The parameter estimation algorithm uses an ARMA model and a recursive QR algorithm is applied for data reduction. In this first evaluation, the algorithm has been applied to a frequency response matrix (which is a particular set of forced mode of vibration) using a sliding frequency window. The objective of the sliding frequency window is to execute the analysis simultaneously with the data acquisition. Since the pole values and the modal density are obtained from this analysis during the acquisition, the analysis information can be used to help determine the forcing vectors during the experimental data acquisition.

  16. Key parameters in testing biodegradation of bio-based materials in soil.

    PubMed

    Briassoulis, D; Mistriotis, A

    2018-09-01

    Biodegradation of plastics in soil is currently tested by international standard testing methods (e.g. ISO 17556-12 or ASTM D5988-12). Although these testing methods have been developed for plastics, it has been shown in project KBBPPS that they can be extended also to lubricants with small modifications. Reproducibility is a critical issue regarding biodegradation tests in the laboratory. Among the main testing variables are the soil types and nutrients available (mainly nitrogen). For this reason, the effect of the soil type on the biodegradation rates of various bio-based materials (cellulose and lubricants) was tested for five different natural soil types (loam, loamy sand, clay, clay-loam, and silt-loam organic). It was shown that use of samples containing 1 g of C in a substrate of 300 g of soil with the addition of 0.1 g of N as nutrient strongly improves the reproducibility of the test making the results practically independent of the soil type with the exception of the organic soil. The sandy soil was found to need addition of higher amount of nutrients to exhibit similar biodegradation rates as those achieved with the other soil types. Therefore, natural soils can be used for Standard biodegradation tests of bio-based materials yielding reproducible results with the addition of appropriate nutrients. Copyright © 2018 Elsevier Ltd. All rights reserved.

  17. Evaluation and benchmarking of an EC-QCL-based mid-infrared spectrometer for monitoring metabolic blood parameters in critical care units

    NASA Astrophysics Data System (ADS)

    Grafen, M.; Delbeck, S.; Busch, H.; Heise, H. M.; Ostendorf, A.

    2018-02-01

    Mid-infrared spectroscopy hyphenated with micro-dialysis is an excellent method for monitoring metabolic blood parameters as it enables the concurrent, reagent-free and precise measurement of multiple clinically relevant substances such as glucose, lactate and urea in micro-dialysates of blood or interstitial fluid. For a marketable implementation, quantum cascade lasers (QCL) seem to represent a favourable technology due to their high degree of miniaturization and potentially low production costs. In this work, an external cavity (EC) - QCL-based spectrometer and two Fourier-transform infrared (FTIR) spectrometers were benchmarked with regard to the precision, accuracy and long-term stability needed for the monitoring of critically ill patients. For the tests, ternary aqueous solutions of glucose, lactate and mannitol (the latter for dialysis recovery determination) were measured in custom-made flow-through transmission cells of different pathlengths and analyzed by Partial Least Squares calibration models. It was revealed, that the wavenumber tuning speed of the QCL had a severe impact on the EC-mirror trajectory due to matching the digital-analog-converter step frequency with the mechanical resonance frequency of the mirror actuation. By selecting an appropriate tuning speed, the mirror oscillations acted as a hardware smoothing filter for the significant intensity variations caused by mode hopping. Besides the tuning speed, the effects of averaging over multiple spectra and software smoothing parameters (Savitzky-Golay-filters and FT-smoothing) were investigated. The final settings led to a performance of the QCL-system, which was comparable with a research FTIR-spectrometer and even surpassed the performance of a small FTIR-mini-spectrometer.

  18. Criticality safety evaluation for the Advanced Test Reactor enhanced low enriched uranium fuel elements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montierth, Leland M.

    2016-07-19

    The Global Threat Reduction Initiative (GTRI) convert program is developing a high uranium density fuel based on a low enriched uranium (LEU) uranium-molybdenum alloy. Testing of prototypic GTRI fuel elements is necessary to demonstrate integrated fuel performance behavior and scale-up of fabrication techniques. GTRI Enhanced LEU Fuel (ELF) elements based on the ATR-Standard Size elements (all plates fueled) are to be fabricated for testing in the Advanced Test Reactor (ATR). While a specific ELF element design will eventually be provided for detailed analyses and in-core testing, this criticality safety evaluation (CSE) is intended to evaluate a hypothetical ELF element designmore » for criticality safety purposes. Existing criticality analyses have analyzed Standard (HEU) ATR elements from which controls have been derived. This CSE documents analysis that determines the reactivity of the hypothetical ELF fuel elements relative to HEU ATR elements and whether the existing HEU ATR element controls bound the ELF element. The initial calculations presented in this CSE analyzed the original ELF design, now referred to as Mod 0.1. In addition, as part of a fuel meat thickness optimization effort for reactor performance, other designs have been evaluated. As of early 2014 the most current conceptual designs are Mk1A and Mk1B, that were previously referred to as conceptual designs Mod 0.10 and Mod 0.11, respectively. Revision 1 evaluates the reactivity of the ATR HEU Mark IV elements for a comparison with the Mark VII elements.« less

  19. Testing electromagnetic fields for potential carcinogenic activity: a critical review of animal models.

    PubMed Central

    McCann, J; Kavet, R; Rafferty, C N

    1997-01-01

    In order to assess the potential of electromagnetic fields (EMF) to influence the process of carcinogenesis, it will be necessary to supplement epidemiological studies with controlled laboratory studies in animals. There are now a number of suitable assays available that focus on different histopathological forms of cancer and on different stages of carcinogenesis--induction, promotion, progression. In this review we discuss eight major systems in the context of this generalized carcinogenesis paradigm. Our aim is to bring together what is currently known about the biology of carcinogenesis in these systems in order to provide a context for evaluating EMF results as they become available. We also critically discuss EMF test results that have so far been obtained in the animal models reviewed. Most of the 19 completed studies identified were negative. However, suggestive positive results were reported in three promotion assays (in rat mammary gland, in rat liver, and in mouse skin), and in one multigeneration study in mice. Results in the rat liver assay and in the multigeneration study have only been reported in abstract form and cannot be adequately evaluated. Positive results reported in both the rat mammary gland and the mouse skin systems are of weak statistical significance and have not been independently replicated. However, it may be of interest that effects in both systems appear primarily to involve the progression stage of carcinogenesis. We suggest that more definitive conclusions as to the carcinogenic potential of EMF may require expanded test protocols that reinforce traditional carcinogenesis end points with biochemical or other parameters reflective of biological processes known to be associated with carcinogenesis in the different systems. PMID:9114279

  20. The Sodium Exposure Test Cell to determine operating parameters for AMTEC electrochemical cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryan, M.A.; Williams, R.M.; Lara, L.

    1998-07-01

    The Sodium Exposure Test Cell (SETC) is a non-power producing cell which has been developed to evaluate and test components of the electrochemical cell in an Alkali Metal Thermal to Electric Converter. Performance and time dependence of performance of the electrode and the electrolyte in AMTEC cells can be tested in an SETC, and performance parameters which correlate with those taken from AMTEC operation can be calculated from data taken in an SETC. The components of the AMTEC electrochemical cell which are evaluated in an SETC are the electrode, {beta}{double{underscore}prime}-alumina solid electrolyte (BASE), the current collection network, and the containment.more » The components are held in low pressure sodium vapor at a temperature which reflects their operating conditions in an AMTEC device, and operating parameters determined. Electrodes and BASE are evaluated by measuring current-voltage (IV) characteristics and using Electrochemical Impedance Spectroscopy (EIS). Using these techniques, electrode performance parameters such as the exchange current (B), the morphology factor (G), and contact resistance between electrode and current collection network can be determined. The ionic conductivity (s) of BASE can also be determined. IV curves and EIS measurements are made at intervals over periods of several hundreds of hours in order to evaluate degradation of AMTEC electrochemical cell components. Electrode and BASE are analyzed after an SETC experiment using Scanning Electron Microscopy, Electron Dispersive Spectroscopy, and X-Ray Diffraction. These techniques allow evaluation of interaction of materials and changes in the composition and structure of materials. The purpose of these experiments is determination of the changes of operating parameters as a function of time in order to predict the operating lifetime of AMTEC cells.« less

  1. Boiling Visualization and Critical Heat Flux Phenomena In Narrow Rectangular Gap

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. J. Kim; Y. H. Kim; S. J. Kim

    2004-12-01

    An experimental study was performed to investifate the pool boling critical hear flux (CHF) on one-dimensional inclined rectangular channels with narrow gaps by changing the orientation of a copper test heater assembly. In a pool of saturated water at atmospheric pressure, the test parameters include the gap sizes of 1,2,5, and 10 mm, andthe surface orientation angles from the downward facing position (180 degrees) to the vertical position (90 degress) respectively.

  2. An analytical approach to obtaining JWL parameters from cylinder tests

    NASA Astrophysics Data System (ADS)

    Sutton, B. D.; Ferguson, J. W.; Hodgson, A. N.

    2017-01-01

    An analytical method for determining parameters for the JWL Equation of State from cylinder test data is described. This method is applied to four datasets obtained from two 20.3 mm diameter EDC37 cylinder tests. The calculated pressure-relative volume (p-Vr) curves agree with those produced by hydro-code modelling. The average calculated Chapman-Jouguet (CJ) pressure is 38.6 GPa, compared to the model value of 38.3 GPa; the CJ relative volume is 0.729 for both. The analytical pressure-relative volume curves produced agree with the one used in the model out to the commonly reported expansion of 7 relative volumes, as do the predicted energies generated by integrating under the p-Vr curve. The calculated energy is within 1.6% of that predicted by the model.

  3. The Question of Spontaneous Wing Oscillations : Determination of Critical Velocity Through Flight-oscillation Tests

    NASA Technical Reports Server (NTRS)

    Schlippe, B V

    1936-01-01

    Determination of the spontaneous oscillations of a wing or tail unit entail many difficulties, both the mathematical determination and the determination by static wing oscillation tests being far from successful and flight tests involving very great risks. The present paper gives a method developed at the Junkers Airplane Company by which the critical velocity with respect to spontaneous oscillations of increasing amplitude can be ascertained in flight tests without undue risks, the oscillation of the surface being obtained in the tests by the application of an external force.

  4. Furosemide/Fludrocortisone Test and Clinical Parameters to Diagnose Incomplete Distal Renal Tubular Acidosis in Kidney Stone Formers.

    PubMed

    Dhayat, Nasser A; Gradwell, Michael W; Pathare, Ganesh; Anderegg, Manuel; Schneider, Lisa; Luethi, David; Mattmann, Cedric; Moe, Orson W; Vogt, Bruno; Fuster, Daniel G

    2017-09-07

    Incomplete distal renal tubular acidosis is a well known cause of calcareous nephrolithiasis but the prevalence is unknown, mostly due to lack of accepted diagnostic tests and criteria. The ammonium chloride test is considered as gold standard for the diagnosis of incomplete distal renal tubular acidosis, but the furosemide/fludrocortisone test was recently proposed as an alternative. Because of the lack of rigorous comparative studies, the validity of the furosemide/fludrocortisone test in stone formers remains unknown. In addition, the performance of conventional, nonprovocative parameters in predicting incomplete distal renal tubular acidosis has not been studied. We conducted a prospective study in an unselected cohort of 170 stone formers that underwent sequential ammonium chloride and furosemide/fludrocortisone testing. Using the ammonium chloride test as gold standard, the prevalence of incomplete distal renal tubular acidosis was 8%. Sensitivity and specificity of the furosemide/fludrocortisone test were 77% and 85%, respectively, yielding a positive predictive value of 30% and a negative predictive value of 98%. Testing of several nonprovocative clinical parameters in the prediction of incomplete distal renal tubular acidosis revealed fasting morning urinary pH and plasma potassium as the most discriminative parameters. The combination of a fasting morning urinary threshold pH <5.3 with a plasma potassium threshold >3.8 mEq/L yielded a negative predictive value of 98% with a sensitivity of 85% and a specificity of 77% for the diagnosis of incomplete distal renal tubular acidosis. The furosemide/fludrocortisone test can be used for incomplete distal renal tubular acidosis screening in stone formers, but an abnormal furosemide/fludrocortisone test result needs confirmation by ammonium chloride testing. Our data furthermore indicate that incomplete distal renal tubular acidosis can reliably be excluded in stone formers by use of nonprovocative clinical

  5. Vestibular evoked myogenic potentials in young children: test parameters and normative data.

    PubMed

    Kelsch, Timothy A; Schaefer, Lynne A; Esquivel, Carlos R

    2006-06-01

    The vestibular evoked myogenic potential (VEMP) is a test of the vestibulocollic reflex that has been extensively studied in adults. Much is known about the normal values in adults as well as their changes with age. In children, the expected test values and their possible changes in development have not yet been described nor has the feasibility of reliable testing in this group. The aim of this prospective study is to accumulate normative data and to verify the viability of testing in young children. The study focused on optimal test parameters, reproducibility, and subject compliance in a pediatric population. Thirty normal-hearing children (60 ears) ages 3 to 11 completed VEMP testing and audiograms for analysis. VEMP testing was performed with alternating clicks at three intensities (80-, 85-, and 90-dB normalized hearing level) using averaged, unrectified electromyograms recorded by surface electrode on the sternocleidomastoid muscle ipsilateral to the stimulus. VEMP latencies, amplitude, compliance, and length of testing were recorded for each patient, as well as their feedback on the testing session. The subjects were divided into four age groups for analysis. All but one of the subjects attempting VEMP testing was able to finish. Of 30 children completing VEMP tests, bilateral reflexes were recorded for all subjects with symmetric responses in 28 of 30 subjects (93%). The mean peak latencies (+/- standard deviation [SD]) of pI and nII were 11.3 msec (1.3 ms) and 17.6 msec (1.4 ms), respectively. The mean pI-nII amplitude (+/- SD) was 122 muV (68 muV). There was a significantly shorter nII mean peak latency of group I (ages 3-5) left ear in comparison to other groups, with an absolute shorter mean latency nII in the right ear of group I (not significant). Average test time was 15 minutes with two researchers testing, and subjects were highly compliant. VEMP is a well-tolerated test for screening vestibular function in young children, performed with minimal

  6. Treated wastewater phytotoxicity assessment using Lactuca sativa: Focus on germination and root elongation test parameters.

    PubMed

    Priac, Anne; Badot, Pierre-Marie; Crini, Grégorio

    2017-03-01

    Sensitive and simple ecotoxicological bioassays like seed germination and root elongation tests are commonly used to evaluate the phytotoxicity of waste and industrial discharge waters. Although the tests are performed following national and international standards, various parameters such as the number of seeds per dish, the test duration or the type of support used remain variable. To be able to make a correct comparison of results from different studies, it is crucial to know which parameter(s) could affect ecotoxicological diagnosis. We tested four different control waters and three seed densities. No significant differences on either germination rate or root elongation endpoints were shown. Nevertheless, we found that the four lettuce cultivars (Appia, batavia dorée de printemps, grosse blonde paresseuse, and Kinemontepas) showed significantly different responses when watered with the same and different metal-loaded industrial discharge water. From the comparison, it is clear that a differential sensitivity scale occurs among not just species but cultivars. Copyright © 2017 Académie des sciences. Published by Elsevier Masson SAS. All rights reserved.

  7. Volume-energy parameters for heat transfer to supercritical fluids

    NASA Technical Reports Server (NTRS)

    Kumakawa, A.; Niino, M.; Hendricks, R. C.; Giarratano, P. J.; Arp, V. D.

    1986-01-01

    Reduced Nusselt numbers of supercritical fluids from different sources were grouped by several volume-energy parameters. A modified bulk expansion parameter was introduced based on a comparative analysis of data scatter. Heat transfer experiments on liquefied methane were conducted under near-critical conditions in order to confirm the usefulness of the parameters. It was experimentally revealed that heat transfer characteristics of near-critical methane are similar to those of hydrogen. It was shown that the modified bulk expansion parameter and the Gibbs-energy parameter grouped the heat transfer data of hydrogen, oxygen and methane including the present data on near-critical methane. It was also indicated that the effects of surface roughness on heat transfer were very important in grouping the data of high Reynolds numbers.

  8. Automated critical test result notification system: architecture, design, and assessment of provider satisfaction.

    PubMed

    Lacson, Ronilda; O'Connor, Stacy D; Andriole, Katherine P; Prevedello, Luciano M; Khorasani, Ramin

    2014-11-01

    Communicating critical results of diagnostic imaging procedures is a national patient safety goal. The purposes of this study were to describe the system architecture and design of Alert Notification of Critical Results (ANCR), an automated system designed to facilitate communication of critical imaging results between care providers; to report providers' satisfaction with ANCR; and to compare radiologists' and ordering providers' attitudes toward ANCR. The design decisions made for each step in the alert communication process, which includes user authentication, alert creation, alert communication, alert acknowledgment and management, alert reminder and escalation, and alert documentation, are described. To assess attitudes toward ANCR, internally developed and validated surveys were administered to all radiologists (n = 320) and ordering providers (n = 4323) who sent or received alerts 3 years after ANCR implementation. The survey response rates were 50.4% for radiologists and 36.1% for ordering providers. Ordering providers were generally dissatisfied with the training received for use of ANCR and with access to technical support. Radiologists were more satisfied with documenting critical result communication (61.1% vs 43.2%; p = 0.0001) and tracking critical results (51.6% vs 35.1%; p = 0.0003) than were ordering providers. Both groups agreed use of ANCR reduces medical errors and improves the quality of patient care. Use of ANCR enables automated communication of critical test results. The survey results confirm overall provider satisfaction with ANCR but highlight the need for improved training strategies for large numbers of geographically dispersed ordering providers. Future enhancements beyond acknowledging receipt of critical results are needed to help ensure timely and appropriate follow-up of critical results to improve quality and patient safety.

  9. Evaluation of unconfined-aquifer parameters from pumping test data by nonlinear least squares

    NASA Astrophysics Data System (ADS)

    Heidari, Manoutchehr; Wench, Allen

    1997-05-01

    Nonlinear least squares (NLS) with automatic differentiation was used to estimate aquifer parameters from drawdown data obtained from published pumping tests conducted in homogeneous, water-table aquifers. The method is based on a technique that seeks to minimize the squares of residuals between observed and calculated drawdown subject to bounds that are placed on the parameter of interest. The analytical model developed by Neuman for flow to a partially penetrating well of infinitesimal diameter situated in an infinite, homogeneous and anisotropic aquifer was used to obtain calculated drawdown. NLS was first applied to synthetic drawdown data from a hypothetical but realistic aquifer to demonstrate that the relevant hydraulic parameters (storativity, specific yield, and horizontal and vertical hydraulic conductivity) can be evaluated accurately. Next the method was used to estimate the parameters at three field sites with widely varying hydraulic properties. NLS produced unbiased estimates of the aquifer parameters that are close to the estimates obtained with the same data using a visual curve-matching approach. Small differences in the estimates are a consequence of subjective interpretation introduced in the visual approach.

  10. Evaluation of unconfined-aquifer parameters from pumping test data by nonlinear least squares

    USGS Publications Warehouse

    Heidari, M.; Moench, A.

    1997-01-01

    Nonlinear least squares (NLS) with automatic differentiation was used to estimate aquifer parameters from drawdown data obtained from published pumping tests conducted in homogeneous, water-table aquifers. The method is based on a technique that seeks to minimize the squares of residuals between observed and calculated drawdown subject to bounds that are placed on the parameter of interest. The analytical model developed by Neuman for flow to a partially penetrating well of infinitesimal diameter situated in an infinite, homogeneous and anisotropic aquifer was used to obtain calculated drawdown. NLS was first applied to synthetic drawdown data from a hypothetical but realistic aquifer to demonstrate that the relevant hydraulic parameters (storativity, specific yield, and horizontal and vertical hydraulic conductivity) can be evaluated accurately. Next the method was used to estimate the parameters at three field sites with widely varying hydraulic properties. NLS produced unbiased estimates of the aquifer parameters that are close to the estimates obtained with the same data using a visual curve-matching approach. Small differences in the estimates are a consequence of subjective interpretation introduced in the visual approach.

  11. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters

    PubMed Central

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-01

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis. PMID:26805819

  12. Combining destination diversion decisions and critical in-flight event diagnosis in computer aided testing of pilots

    NASA Technical Reports Server (NTRS)

    Rockwell, T. H.; Giffin, W. C.; Romer, D. J.

    1984-01-01

    Rockwell and Giffin (1982) and Giffin and Rockwell (1983) have discussed the use of computer aided testing (CAT) in the study of pilot response to critical in-flight events. The present investigation represents an extension of these earlier studies. In testing pilot responses to critical in-flight events, use is made of a Plato-touch CRT system operating on a menu based format. In connection with the typical diagnostic problem, the pilot was presented with symptoms within a flight scenario. In one problem, the pilot has four minutes for obtaining the information which is needed to make a diagnosis of the problem. In the reported research, the attempt has been made to combine both diagnosis and diversion scenario into a single computer aided test. Tests with nine subjects were conducted. The obtained results and their significance are discussed.

  13. Exact Critical Exponents for the Antiferromagnetic Quantum Critical Metal in Two Dimensions

    NASA Astrophysics Data System (ADS)

    Schlief, Andres; Lunts, Peter; Lee, Sung-Sik

    2017-04-01

    Unconventional metallic states which do not support well-defined single-particle excitations can arise near quantum phase transitions as strong quantum fluctuations of incipient order parameters prevent electrons from forming coherent quasiparticles. Although antiferromagnetic phase transitions occur commonly in correlated metals, understanding the nature of the strange metal realized at the critical point in layered systems has been hampered by a lack of reliable theoretical methods that take into account strong quantum fluctuations. We present a nonperturbative solution to the low-energy theory for the antiferromagnetic quantum critical metal in two spatial dimensions. Being a strongly coupled theory, it can still be solved reliably in the low-energy limit as quantum fluctuations are organized by a new control parameter that emerges dynamically. We predict the exact critical exponents that govern the universal scaling of physical observables at low temperatures.

  14. Analysis test of understanding of vectors with the three-parameter logistic model of item response theory and item response curves technique

    NASA Astrophysics Data System (ADS)

    Rakkapao, Suttida; Prasitpong, Singha; Arayathanitkul, Kwan

    2016-12-01

    This study investigated the multiple-choice test of understanding of vectors (TUV), by applying item response theory (IRT). The difficulty, discriminatory, and guessing parameters of the TUV items were fit with the three-parameter logistic model of IRT, using the parscale program. The TUV ability is an ability parameter, here estimated assuming unidimensionality and local independence. Moreover, all distractors of the TUV were analyzed from item response curves (IRC) that represent simplified IRT. Data were gathered on 2392 science and engineering freshmen, from three universities in Thailand. The results revealed IRT analysis to be useful in assessing the test since its item parameters are independent of the ability parameters. The IRT framework reveals item-level information, and indicates appropriate ability ranges for the test. Moreover, the IRC analysis can be used to assess the effectiveness of the test's distractors. Both IRT and IRC approaches reveal test characteristics beyond those revealed by the classical analysis methods of tests. Test developers can apply these methods to diagnose and evaluate the features of items at various ability levels of test takers.

  15. A drilling tool design and in situ identification of planetary regolith mechanical parameters

    NASA Astrophysics Data System (ADS)

    Zhang, Weiwei; Jiang, Shengyuan; Ji, Jie; Tang, Dewei

    2018-05-01

    The physical and mechanical properties as well as the heat flux of regolith are critical evidence in the study of planetary origin and evolution. Moreover, the mechanical properties of planetary regolith have great value for guiding future human planetary activities. For planetary subsurface exploration, an inchworm boring robot (IBR) has been proposed to penetrate the regolith, and the mechanical properties of the regolith are expected to be simultaneously investigated during the penetration process using the drilling tool on the IBR. This paper provides a preliminary study of an in situ method for measuring planetary regolith mechanical parameters using a drilling tool on a test bed. A conical-screw drilling tool was designed, and its drilling load characteristics were experimentally analyzed. Based on the drilling tool-regolith interaction model, two identification methods for determining the planetary regolith bearing and shearing parameters are proposed. The bearing and shearing parameters of lunar regolith simulant were successfully determined according to the pressure-sinkage tests and shear tests conducted on the test bed. The effects of the operating parameters on the identification results were also analyzed. The results indicate a feasible scheme for future planetary subsurface exploration.

  16. Electromigration kinetics and critical current of Pb-free interconnects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Minhua; Rosenberg, Robert

    2014-04-07

    Electromigration kinetics of Pb-free solder bump interconnects have been studied using a single bump parameter sweep technique. By removing bump to bump variations in structure, texture, and composition, the single bump sweep technique has provided both activation energy and power exponents that reflect atomic migration and interface reactions with fewer samples, shorter stress time, and better statistics than standard failure testing procedures. Contact metallurgies based on Cu and Ni have been studied. Critical current, which corresponds to the Blech limit, was found to exist in the Ni metallurgy, but not in the Cu metallurgy. A temperature dependence of critical currentmore » was also observed.« less

  17. European tests on materials outgassing

    NASA Technical Reports Server (NTRS)

    Zwaal, A.

    1977-01-01

    With a view to international coordination of spacecraft materials, a number of European firms and institutes performed outgassing tests on identical materials at 125 C in high vacuum. The outgassing data obtained with the different types of equipment is presented and both the results and the critical parameters are discussed.

  18. Automated Critical Test Result Notification System: Architecture, Design, and Assessment of Provider Satisfaction

    PubMed Central

    Lacson, Ronilda; O'Connor, Stacy D.; Andriole, Katherine P.; Prevedello, Luciano M.; Khorasani, Ramin

    2015-01-01

    OBJECTIVE Communicating critical results of diagnostic imaging procedures is a national patient safety goal. The purposes of this study were to describe the system architecture and design of Alert Notification of Critical Results (ANCR), an automated system designed to facilitate communication of critical imaging results between care providers; to report providers’ satisfaction with ANCR; and to compare radiologists’ and ordering providers’ attitudes toward ANCR. MATERIALS AND METHODS The design decisions made for each step in the alert communication process, which includes user authentication, alert creation, alert communication, alert acknowledgment and management, alert reminder and escalation, and alert documentation, are described. To assess attitudes toward ANCR, internally developed and validated surveys were administered to all radiologists (n = 320) and ordering providers (n = 4323) who sent or received alerts 3 years after ANCR implementation. RESULTS The survey response rates were 50.4% for radiologists and 36.1% for ordering providers. Ordering providers were generally dissatisfied with the training received for use of ANCR and with access to technical support. Radiologists were more satisfied with documenting critical result communication (61.1% vs 43.2%; p = 0.0001) and tracking critical results (51.6% vs 35.1%; p = 0.0003) than were ordering providers. Both groups agreed use of ANCR reduces medical errors and improves the quality of patient care. CONCLUSION Use of ANCR enables automated communication of critical test results. The survey results confirm overall provider satisfaction with ANCR but highlight the need for improved training strategies for large numbers of geographically dispersed ordering providers. Future enhancements beyond acknowledging receipt of critical results are needed to help ensure timely and appropriate follow-up of critical results to improve quality and patient safety. PMID:25341163

  19. Unified Scaling Law for flux pinning in practical superconductors: II. Parameter testing, scaling constants, and the Extrapolative Scaling Expression

    NASA Astrophysics Data System (ADS)

    Ekin, Jack W.; Cheggour, Najib; Goodrich, Loren; Splett, Jolene; Bordini, Bernardo; Richter, David

    2016-12-01

    A scaling study of several thousand Nb3Sn critical-current (I c) measurements is used to derive the Extrapolative Scaling Expression (ESE), a relation that can quickly and accurately extrapolate limited datasets to obtain full three-dimensional dependences of I c on magnetic field (B), temperature (T), and mechanical strain (ɛ). The relation has the advantage of being easy to implement, and offers significant savings in sample characterization time and a useful tool for magnet design. Thorough data-based analysis of the general parameterization of the Unified Scaling Law (USL) shows the existence of three universal scaling constants for practical Nb3Sn conductors. The study also identifies the scaling parameters that are conductor specific and need to be fitted to each conductor. This investigation includes two new, rare, and very large I c(B,T,ɛ) datasets (each with nearly a thousand I c measurements spanning magnetic fields from 1 to 16 T, temperatures from ˜2.26 to 14 K, and intrinsic strains from -1.1% to +0.3%). The results are summarized in terms of the general USL parameters given in table 3 of Part 1 (Ekin J W 2010 Supercond. Sci. Technol. 23 083001) of this series of articles. The scaling constants determined for practical Nb3Sn conductors are: the upper-critical-field temperature parameter v = 1.50 ± 0.04 the cross-link parameter w = 3.0 ± 0.3 and the strain curvature parameter u = 1.7 ± 0.1 (from equation (29) for b c2(ɛ) in Part 1). These constants and required fitting parameters result in the ESE relation, given by I c ( B , T , ɛ ) B = C [ b c 2 ( ɛ ) ] s ( 1 - t 1.5 ) η - μ ( 1 - t 2 ) μ b p ( 1 - b ) q with reduced magnetic field b ≡ B/B c2*(T,ɛ) and reduced temperature t ≡ T/T c*(ɛ), where: B c 2 * ( T , ɛ ) = B c 2 * ( 0 , 0 ) ( 1 - t 1.5 ) b c 2 ( ɛ ) T c * ( ɛ ) = T c * ( 0 ) [ b c 2 ( ɛ ) ] 1/3 and fitting parameters: C, B c2*(0,0), T c*(0), s, either η or μ (but not both), plus the parameters in the strain function b c2

  20. The effect of different calculation methods of flywheel parameters on the Wingate Anaerobic Test.

    PubMed

    Coleman, S G; Hale, T

    1998-08-01

    Researchers compared different methods of calculating kinetic parameters of friction-braked cycle ergometers, and the subsequent effects on calculating power outputs in the Wingate Anaerobic Test (WAnT). Three methods of determining flywheel moment of inertia and frictional torque were investigated, requiring "run-down" tests and segmental geometry. Parameters were used to calculate corrected power outputs from 10 males in a 30-s WAnT against a load related to body mass (0.075 kg.kg-1). Wingate Indices of maximum (5 s) power, work, and fatigue index were also compared. Significant differences were found between uncorrected and corrected power outputs and between correction methods (p < .05). The same finding was evident for all Wingate Indices (p < .05). Results suggest that WAnT must be corrected to give true power outputs and that choosing an appropriate correction calculation is important. Determining flywheel moment of inertia and frictional torque using unloaded run-down tests is recommended.

  1. Enhancing students’ critical thinking skills through critical thinking assessment in calculus course

    NASA Astrophysics Data System (ADS)

    Zulfaneti; Edriati, S.; Mukhni

    2018-01-01

    This study aims to determine the development of students’ critical thinking skills through the implementation of critical thinking instruments in Calculus lectures. The instruments consist of observation sheets, critical thinking test, self-assessment, peer assessment and portfolio. The research was a qualitative research; with the participants were 53 first-year students who take Integral Calculus in Mathematics Education Department STKIP PGRI Sumatera Barat representing high-ability students, medium and low. The data in this study were collected by tests, interviews, observations and field notes. Data were analyzed descriptively; data reduction, data presentation, and conclusions. For testing the validity of data, it was used credibility test data by increasing persistence and triangulation. The results showed that in high-level students there is a change of ability from Critical enough to be Very Critical, in the students with moderate and low ability there is a change of ability from Uncritical to Critical. So it can be concluded that the assessment instruments have a good contribution and can improve the ability of critical thinking.

  2. Testing parameters of TMR heads affected by dynamic-tester induced EMI

    NASA Astrophysics Data System (ADS)

    Kruesubthaworn, A.; Sivaratana, R.; Ungvichian, V.; Siritaratiwat, A.

    2007-09-01

    A variety of expected electromagnetic interference (EMI) sources of both radiated and conducted EMI emissions produced by a dynamic tester is studied. It is determined that the power cable connector of the robot arm radiates a significant electric field (E-field) of about 197 V/m at 1 foot away and an estimated calculation of the E-field of about 212 mV/m is at the spindle motor. These fields can be attenuated by about 20-30 dB when using a copper lined Faraday's cage. Furthermore, the study has revealed that the radiated EMI plays a more significant role than the conducted EMI. In addition, it is determined that out of seven selected testing parameters, the SGAW is rather more sensitive to EMI than conventional failure parameters, especially static glitche during the write cycle.

  3. A review of pharmaceutical extrusion: critical process parameters and scaling-up.

    PubMed

    Thiry, J; Krier, F; Evrard, B

    2015-02-01

    Hot melt extrusion has been a widely used process in the pharmaceutical area for three decades. In this field, it is important to optimize the formulation in order to meet specific requirements. However, the process parameters of the extruder should be as much investigated as the formulation since they have a major impact on the final product characteristics. Moreover, a design space should be defined in order to obtain the expected product within the defined limits. This gives some freedom to operate as long as the processing parameters stay within the limits of the design space. Those limits can be investigated by varying randomly the process parameters but it is recommended to use design of experiments. An examination of the literature is reported in this review to summarize the impact of the variation of the process parameters on the final product properties. Indeed, the homogeneity of the mixing, the state of the drug (crystalline or amorphous), the dissolution rate, the residence time, can be influenced by variations in the process parameters. In particular, the impact of the following process parameters: temperature, screw design, screw speed and feeding, on the final product, has been reviewed. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Effect of Common Cryoprotectants on Critical Warming Rates and Ice Formation in Aqueous Solutions

    PubMed Central

    Hopkins, Jesse B.; Badeau, Ryan; Warkentin, Matthew; Thorne, Robert E.

    2012-01-01

    Ice formation on warming is of comparable or greater importance to ice formation on cooling in determining survival of cryopreserved samples. Critical warming rates required for ice-free warming of vitrified aqueous solutions of glycerol, dimethyl sulfoxide, ethylene glycol, polyethylene glycol 200 and sucrose have been measured for warming rates of order 10 to 104 K/s. Critical warming rates are typically one to three orders of magnitude larger than critical cooling rates. Warming rates vary strongly with cooling rates, perhaps due to the presence of small ice fractions in nominally vitrified samples. Critical warming and cooling rate data spanning orders of magnitude in rates provide rigorous tests of ice nucleation and growth models and their assumed input parameters. Current models with current best estimates for input parameters provide a reasonable account of critical warming rates for glycerol solutions at high concentrations/low rates, but overestimate both critical warming and cooling rates by orders of magnitude at lower concentrations and larger rates. In vitrification protocols, minimizing concentrations of potentially damaging cryoprotectants while minimizing ice formation will require ultrafast warming rates, as well as fast cooling rates to minimize the required warming rates. PMID:22728046

  5. Critical points of metal vapors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khomkin, A. L., E-mail: alhomkin@mail.ru; Shumikhin, A. S.

    2015-09-15

    A new method is proposed for calculating the parameters of critical points and binodals for the vapor–liquid (insulator–metal) phase transition in vapors of metals with multielectron valence shells. The method is based on a model developed earlier for the vapors of alkali metals, atomic hydrogen, and exciton gas, proceeding from the assumption that the cohesion determining the basic characteristics of metals under normal conditions is also responsible for their properties in the vicinity of the critical point. It is proposed to calculate the cohesion of multielectron atoms using well-known scaling relations for the binding energy, which are constructed for mostmore » metals in the periodic table by processing the results of many numerical calculations. The adopted model allows the parameters of critical points and binodals for the vapor–liquid phase transition in metal vapors to be calculated using published data on the properties of metals under normal conditions. The parameters of critical points have been calculated for a large number of metals and show satisfactory agreement with experimental data for alkali metals and with available estimates for all other metals. Binodals of metals have been calculated for the first time.« less

  6. Experience using individually supplied heater rods in critical power testing of advanced BWR fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Majed, M.; Morback, G.; Wiman, P.

    1995-09-01

    The ABB Atom FRIGG loop located in Vasteras Sweden has during the last six years given a large experience of critical power measurements for BWR fuel designs using indirectly heated rods with individual power supply. The loop was built in the sixties and designed for maximum 100 bar pressure. Testing up to the mid eighties was performed with directly heated rods using a 9 MW, 80 kA power supply. Providing test data to develop critical power correlations for BWR fuel assemblies requires testing with many radial power distributions over the full range of hydraulic conditions. Indirectly heated rods give largemore » advantages for the testing procedure, particularly convenient for variation of individual rod power. A test method being used at Stern Laboratories (formerly Westinghouse Canada) since the early sixties, allows one fuel assembly to simulate all required radial power distributions. This technique requires reliable indirectly heated rods with independently controlled power supplies and uses insulated electric fuel rod simulators with built-in instrumentation. The FRIGG loop was adapted to this system in 1987. A 4MW power supply with 10 individual units was then installed, and has since been used for testing 24 and 25 rod bundles simulating one subbundle of SVEA-96/100 type fuel assemblies. The experience with the system is very good, as being presented, and it is selected also for a planned upgrading of the facility to 15 MW.« less

  7. Design of experiments reveals critical parameters for pilot-scale freeze-and-thaw processing of L-lactic dehydrogenase.

    PubMed

    Roessl, Ulrich; Humi, Sebastian; Leitgeb, Stefan; Nidetzky, Bernd

    2015-09-01

    Freezing constitutes an important unit operation of biotechnological protein production. Effects of freeze-and-thaw (F/T) process parameters on stability and other quality attributes of the protein product are usually not well understood. Here a design of experiments (DoE) approach was used to characterize the F/T behavior of L-lactic dehydrogenase (LDH) in a 700-mL pilot-scale freeze container equipped with internal temperature and pH probes. In 24-hour experiments, target temperature between -10 and -38°C most strongly affected LDH stability whereby enzyme activity was retained best at the highest temperature of -10°C. Cooling profile and liquid fill volume also had significant effects on LDH stability and affected the protein aggregation significantly. Parameters of the thawing phase had a comparably small effect on LDH stability. Experiments in which the standard sodium phosphate buffer was exchanged by Tris-HCl and the non-ionic surfactant Tween 80 was added to the protein solution showed that pH shift during freezing and protein surface exposure were the main factors responsible for LDH instability at the lower freeze temperatures. Collectively, evidence is presented that supports the use of DoE-based systematic analysis at pilot scale in the identification of F/T process parameters critical for protein stability and in the development of suitable process control strategies. Copyright © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Critical level setting of continuous air monitor.

    PubMed

    Li, Huibin; Jia, Mingyan; Wang, Kailiang

    2013-01-01

    Algorithms used to compensate the radon and thoron progeny's interference are one of the key technologies for continuous air monitors (CAMs). In this study, a CAM that can automatically change filter was manufactured, and equations used to calculate the transuranic aerosol concentration and the corresponding critical level were derived. The parameters used in calculation were acquired by continuous measurement in a high radon environment. At last, validation of the calculation was tested in a cave where the radon concentration fluctuated frequently, and the results were analysed.

  9. Engineering Parameters in Bioreactor's Design: A Critical Aspect in Tissue Engineering

    PubMed Central

    Amoabediny, Ghassem; Pouran, Behdad; Tabesh, Hadi; Shokrgozar, Mohammad Ali; Haghighipour, Nooshin; Khatibi, Nahid; Mottaghy, Khosrow; Zandieh-Doulabi, Behrouz

    2013-01-01

    Bioreactors are important inevitable part of any tissue engineering (TE) strategy as they aid the construction of three-dimensional functional tissues. Since the ultimate aim of a bioreactor is to create a biological product, the engineering parameters, for example, internal and external mass transfer, fluid velocity, shear stress, electrical current distribution, and so forth, are worth to be thoroughly investigated. The effects of such engineering parameters on biological cultures have been addressed in only a few preceding studies. Furthermore, it would be highly inefficient to determine the optimal engineering parameters by trial and error method. A solution is provided by emerging modeling and computational tools and by analyzing oxygen, carbon dioxide, and nutrient and metabolism waste material transports, which can simulate and predict the experimental results. Discovering the optimal engineering parameters is crucial not only to reduce the cost and time of experiments, but also to enhance efficacy and functionality of the tissue construct. This review intends to provide an inclusive package of the engineering parameters together with their calculation procedure in addition to the modeling techniques in TE bioreactors. PMID:24000327

  10. Engineering parameters in bioreactor's design: a critical aspect in tissue engineering.

    PubMed

    Salehi-Nik, Nasim; Amoabediny, Ghassem; Pouran, Behdad; Tabesh, Hadi; Shokrgozar, Mohammad Ali; Haghighipour, Nooshin; Khatibi, Nahid; Anisi, Fatemeh; Mottaghy, Khosrow; Zandieh-Doulabi, Behrouz

    2013-01-01

    Bioreactors are important inevitable part of any tissue engineering (TE) strategy as they aid the construction of three-dimensional functional tissues. Since the ultimate aim of a bioreactor is to create a biological product, the engineering parameters, for example, internal and external mass transfer, fluid velocity, shear stress, electrical current distribution, and so forth, are worth to be thoroughly investigated. The effects of such engineering parameters on biological cultures have been addressed in only a few preceding studies. Furthermore, it would be highly inefficient to determine the optimal engineering parameters by trial and error method. A solution is provided by emerging modeling and computational tools and by analyzing oxygen, carbon dioxide, and nutrient and metabolism waste material transports, which can simulate and predict the experimental results. Discovering the optimal engineering parameters is crucial not only to reduce the cost and time of experiments, but also to enhance efficacy and functionality of the tissue construct. This review intends to provide an inclusive package of the engineering parameters together with their calculation procedure in addition to the modeling techniques in TE bioreactors.

  11. Fitted hyperelastic parameters for Human brain tissue from reported tension, compression, and shear tests.

    PubMed

    Moran, Richard; Smith, Joshua H; García, José J

    2014-11-28

    The mechanical properties of human brain tissue are the subject of interest because of their use in understanding brain trauma and in developing therapeutic treatments and procedures. To represent the behavior of the tissue, we have developed hyperelastic mechanical models whose parameters are fitted in accordance with experimental test results. However, most studies available in the literature have fitted parameters with data of a single type of loading, such as tension, compression, or shear. Recently, Jin et al. (Journal of Biomechanics 46:2795-2801, 2013) reported data from ex vivo tests of human brain tissue under tension, compression, and shear loading using four strain rates and four different brain regions. However, they do not report parameters of energy functions that can be readily used in finite element simulations. To represent the tissue behavior for the quasi-static loading conditions, we aimed to determine the best fit of the hyperelastic parameters of the hyperfoam, Ogden, and polynomial strain energy functions available in ABAQUS for the low strain rate data, while simultaneously considering all three loading modes. We used an optimization process conducted in MATLAB, calling iteratively three finite element models developed in ABAQUS that represent the three loadings. Results showed a relatively good fit to experimental data in all loading modes using two terms in the energy functions. Values for the shear modulus obtained in this analysis (897-1653Pa) are in the range of those presented in other studies. These energy-function parameters can be used in brain tissue simulations using finite element models. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Development of a Culture Specific Critical Thinking Ability Test and Using It as a Supportive Diagnostic Test for Giftedness

    ERIC Educational Resources Information Center

    Köksal, Mustafa Serdar

    2016-01-01

    The purposes of this study were to develop a culture specific critical thinking ability test for 6, 7, and 8. grade students in Turkey and to use it as an assessment instrument for giftedness. For these purposes, item pool involving 22 items was formed by writing items focusing on the current and common events presented in (Turkish) media from…

  13. The Impact of Escape Alternative Position Change in Multiple-Choice Test on the Psychometric Properties of a Test and Its Items Parameters

    ERIC Educational Resources Information Center

    Hamadneh, Iyad Mohammed

    2015-01-01

    This study aimed at investigating the impact changing of escape alternative position in multiple-choice test on the psychometric properties of a test and it's items parameters (difficulty, discrimination & guessing), and estimation of examinee ability. To achieve the study objectives, a 4-alternative multiple choice type achievement test…

  14. Virtual Shaker Testing: Simulation Technology Improves Vibration Test Performance

    NASA Technical Reports Server (NTRS)

    Ricci, Stefano; Peeters, Bart; Fetter, Rebecca; Boland, Doug; Debille, Jan

    2008-01-01

    In the field of vibration testing, the interaction between the structure being tested and the instrumentation hardware used to perform the test is a critical issue. This is particularly true when testing massive structures (e.g. satellites), because due to physical design and manufacturing limits, the dynamics of the testing facility often couples with the test specimen one in the frequency range of interest. A further issue in this field is the standard use of a closed loop real-time vibration control scheme, which could potentially shift poles and change damping of the aforementioned coupled system. Virtual shaker testing is a novel approach to deal with these issues. It means performing a simulation which closely represents the real vibration test on the specific facility by taking into account all parameters which might impact the dynamic behavior of the specimen. In this paper, such a virtual shaker testing approach is developed. It consists of the following components: (1) Either a physical-based or an equation-based coupled electro-mechanical lumped parameter shaker model is created. The model parameters are obtained from manufacturer's specifications or by carrying out some dedicated experiments; (2) Existing real-time vibration control algorithm are ported to the virtual simulation environment; and (3) A structural model of the test object is created and after defining proper interface conditions structural modes are computed by means of the well-established Craig-Bampton CMS technique. At this stage, a virtual shaker test has been run, by coupling the three described models (shaker, control loop, structure) in a co-simulation routine. Numerical results have eventually been correlated with experimental ones in order to assess the robustness of the proposed methodology.

  15. How one might miss early warning signals of critical transitions in time series data: A systematic study of two major currency pairs

    PubMed Central

    Ciamarra, Massimo Pica; Cheong, Siew Ann

    2018-01-01

    There is growing interest in the use of critical slowing down and critical fluctuations as early warning signals for critical transitions in different complex systems. However, while some studies found them effective, others found the opposite. In this paper, we investigated why this might be so, by testing three commonly used indicators: lag-1 autocorrelation, variance, and low-frequency power spectrum at anticipating critical transitions in the very-high-frequency time series data of the Australian Dollar-Japanese Yen and Swiss Franc-Japanese Yen exchange rates. Besides testing rising trends in these indicators at a strict level of confidence using the Kendall-tau test, we also required statistically significant early warning signals to be concurrent in the three indicators, which must rise to appreciable values. We then found for our data set the optimum parameters for discovering critical transitions, and showed that the set of critical transitions found is generally insensitive to variations in the parameters. Suspecting that negative results in the literature are the results of low data frequencies, we created time series with time intervals over three orders of magnitude from the raw data, and tested them for early warning signals. Early warning signals can be reliably found only if the time interval of the data is shorter than the time scale of critical transitions in our complex system of interest. Finally, we compared the set of time windows with statistically significant early warning signals with the set of time windows followed by large movements, to conclude that the early warning signals indeed provide reliable information on impending critical transitions. This reliability becomes more compelling statistically the more events we test. PMID:29538373

  16. How one might miss early warning signals of critical transitions in time series data: A systematic study of two major currency pairs.

    PubMed

    Wen, Haoyu; Ciamarra, Massimo Pica; Cheong, Siew Ann

    2018-01-01

    There is growing interest in the use of critical slowing down and critical fluctuations as early warning signals for critical transitions in different complex systems. However, while some studies found them effective, others found the opposite. In this paper, we investigated why this might be so, by testing three commonly used indicators: lag-1 autocorrelation, variance, and low-frequency power spectrum at anticipating critical transitions in the very-high-frequency time series data of the Australian Dollar-Japanese Yen and Swiss Franc-Japanese Yen exchange rates. Besides testing rising trends in these indicators at a strict level of confidence using the Kendall-tau test, we also required statistically significant early warning signals to be concurrent in the three indicators, which must rise to appreciable values. We then found for our data set the optimum parameters for discovering critical transitions, and showed that the set of critical transitions found is generally insensitive to variations in the parameters. Suspecting that negative results in the literature are the results of low data frequencies, we created time series with time intervals over three orders of magnitude from the raw data, and tested them for early warning signals. Early warning signals can be reliably found only if the time interval of the data is shorter than the time scale of critical transitions in our complex system of interest. Finally, we compared the set of time windows with statistically significant early warning signals with the set of time windows followed by large movements, to conclude that the early warning signals indeed provide reliable information on impending critical transitions. This reliability becomes more compelling statistically the more events we test.

  17. Subsonic flight test evaluation of a propulsion system parameter estimation process for the F100 engine

    NASA Technical Reports Server (NTRS)

    Orme, John S.; Gilyard, Glenn B.

    1992-01-01

    Integrated engine-airframe optimal control technology may significantly improve aircraft performance. This technology requires a reliable and accurate parameter estimator to predict unmeasured variables. To develop this technology base, NASA Dryden Flight Research Facility (Edwards, CA), McDonnell Aircraft Company (St. Louis, MO), and Pratt & Whitney (West Palm Beach, FL) have developed and flight-tested an adaptive performance seeking control system which optimizes the quasi-steady-state performance of the F-15 propulsion system. This paper presents flight and ground test evaluations of the propulsion system parameter estimation process used by the performance seeking control system. The estimator consists of a compact propulsion system model and an extended Kalman filter. The extended Laman filter estimates five engine component deviation parameters from measured inputs. The compact model uses measurements and Kalman-filter estimates as inputs to predict unmeasured propulsion parameters such as net propulsive force and fan stall margin. The ability to track trends and estimate absolute values of propulsion system parameters was demonstrated. For example, thrust stand results show a good correlation, especially in trends, between the performance seeking control estimated and measured thrust.

  18. Critical Joints in Large Composite Primary Aircraft Structures. Volume 3: Ancillary Test Results

    NASA Technical Reports Server (NTRS)

    Bunin, Bruce L.; Sagui, R. L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints for composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of a comprehensive ancillary test program are summarized, consisting of single-bolt composite joint specimens tested in a variety of configurations. These tests were conducted to characterize the strength and load deflection properties that are required for multirow joint analysis. The composite material was Toray 300 fiber and Ciba-Geigy 914 resin, in the form of 0.005 and 0.01 inch thick unidirectional tape. Tests were conducted in single and double shear for loaded and unloaded hole configurations under both tensile and compressive loading. Two different layup patterns were examined. All tests were conducted at room temperature. In addition, the results of NASA Standard Toughness Test (NASA RP 1092) are reported, which were conducted for several material systems.

  19. High-Pressure Oxygen Test Evaluations

    NASA Technical Reports Server (NTRS)

    Schwinghamer, R. J.; Key, C. F.

    1974-01-01

    The relevance of impact sensitivity testing to the development of the space shuttle main engine is discussed in the light of the special requirements for the engine. The background and history of the evolution of liquid and gaseous oxygen testing techniques and philosophy is discussed also. The parameters critical to reliable testing are treated in considerable detail, and test apparatus and procedures are described and discussed. Materials threshold sensitivity determination procedures are considered and a decision logic diagram for sensitivity threshold determination was plotted. Finally, high-pressure materials sensitivity test data are given for selected metallic and nonmetallic materials.

  20. Failure modes and effects criticality analysis and accelerated life testing of LEDs for medical applications

    NASA Astrophysics Data System (ADS)

    Sawant, M.; Christou, A.

    2012-12-01

    While use of LEDs in Fiber Optics and lighting applications is common, their use in medical diagnostic applications is not very extensive. Since the precise value of light intensity will be used to interpret patient results, understanding failure modes [1-4] is very important. We used the Failure Modes and Effects Criticality Analysis (FMECA) tool to identify the critical failure modes of the LEDs. FMECA involves identification of various failure modes, their effects on the system (LED optical output in this context), their frequency of occurrence, severity and the criticality of the failure modes. The competing failure modes/mechanisms were degradation of: active layer (where electron-hole recombination occurs to emit light), electrodes (provides electrical contact to the semiconductor chip), Indium Tin Oxide (ITO) surface layer (used to improve current spreading and light extraction), plastic encapsulation (protective polymer layer) and packaging failures (bond wires, heat sink separation). A FMECA table is constructed and the criticality is calculated by estimating the failure effect probability (β), failure mode ratio (α), failure rate (λ) and the operating time. Once the critical failure modes were identified, the next steps were generation of prior time to failure distribution and comparing with our accelerated life test data. To generate the prior distributions, data and results from previous investigations were utilized [5-33] where reliability test results of similar LEDs were reported. From the graphs or tabular data, we extracted the time required for the optical power output to reach 80% of its initial value. This is our failure criterion for the medical diagnostic application. Analysis of published data for different LED materials (AlGaInP, GaN, AlGaAs), the Semiconductor Structures (DH, MQW) and the mode of testing (DC, Pulsed) was carried out. The data was categorized according to the materials system and LED structure such as AlGaInP-DH-DC, Al

  1. Research on computer aided testing of pilot response to critical in-flight events

    NASA Technical Reports Server (NTRS)

    Giffin, W. C.; Rockwell, T. H.; Smith, P. J.

    1984-01-01

    Experiments on pilot decision making are described. The development of models of pilot decision making in critical in flight events (CIFE) are emphasized. The following tests are reported on the development of: (1) a frame system representation describing how pilots use their knowledge in a fault diagnosis task; (2) assessment of script norms, distance measures, and Markov models developed from computer aided testing (CAT) data; and (3) performance ranking of subject data. It is demonstrated that interactive computer aided testing either by touch CRT's or personal computers is a useful research and training device for measuring pilot information management in diagnosing system failures in simulated flight situations. Performance is dictated by knowledge of aircraft sybsystems, initial pilot structuring of the failure symptoms and efficient testing of plausible causal hypotheses.

  2. Active Learning and Threshold Concepts in Multiple Testing That Can Further Develop Student Critical Statistical Thinking

    ERIC Educational Resources Information Center

    White, Desley

    2015-01-01

    Two practical activities are described, which aim to support critical thinking about statistics as they concern multiple outcomes testing. Formulae are presented in Microsoft Excel spreadsheets, which are used to calculate the inflation of error associated with the quantity of tests performed. This is followed by a decision-making exercise, where…

  3. Estimation of critical end-test torque using neuromuscular electrical stimulation of the quadriceps in humans.

    PubMed

    Janzen, Natalie R; Hight, Robert E; Patel, Darshit S; Campbell, Jason A; Larson, Rebecca D; Black, Christopher D

    2018-05-02

    Characterization of critical power/torque (CP/CT) during voluntary exercise requires maximal effort, making difficult for those with neuromuscular impairments. To address this issue we sought to determine if electrically stimulated intermittent isometric exercise resulted in a critical end-test torque (ETT) that behaved similar to voluntary CT. In the first experiment participants (n = 9) completed four bouts of stimulated exercise at a 3:2 duty cycle, at frequencies of 100, 50, 25 Hz, and a low frequency below ETT (Sub-ETT; ≤ 15 Hz). The second experiment (n = 20) consisted of four bouts at a 2:2 duty cycle-two bouts at 100 Hz, one at an intermediate frequency (15-30 Hz), and one at Sub-ETT. The third experiment (n = 12) consisted of two bouts at 50 Hz at a 3:2 duty* cycle with proximal blood flow occlusion during one of the bouts. ETT torque was similar (p ≥ 0.43) within and among stimulation frequencies in experiment 1. No fatigue was observed during the Sub-ETT bouts (p > 0.05). For experiment 2, ETT was similar at 100 Hz and at the intermediate frequency (p ≥ 0.29). Again, Sub-ETT stimulation did not result in fatigue (p > 0.05). Altering oxygen delivery by altering the duty cycle (3:2 vs. 2:2; p = 0.02) and by occlusion (p < 0.001) resulted in lower ETT values. Stimulated exercise resulted in an ETT that was consistent from day-to-day and similar regardless of initial torque, as long as that torque exceeded ETT, and was sensitive to oxygen delivery. As such we propose it represents a parameter similar to voluntary CT.

  4. The Effect of Error in Item Parameter Estimates on the Test Response Function Method of Linking.

    ERIC Educational Resources Information Center

    Kaskowitz, Gary S.; De Ayala, R. J.

    2001-01-01

    Studied the effect of item parameter estimation for computation of linking coefficients for the test response function (TRF) linking/equating method. Simulation results showed that linking was more accurate when there was less error in the parameter estimates, and that 15 or 25 common items provided better results than 5 common items under both…

  5. Fixation parameter test-retest repeatability of the worse eye in central field loss.

    PubMed

    Samet, Saba; Tarita-Nistor, Luminita; González, Esther G; Mandelcorn, Mark S; Mandelcorn, Efrem D; Steinbach, Martin J

    2018-06-01

    Patients with bilateral central field loss develop peripheral retinal loci (PRLs) in the functional eccentric retina. PRL characteristics and visual performance in the better-seeing eye (BE) of these patients have previously been reported. In this study, we determined the test-retest repeatability of fixation parameters, including fixation stability, PRL eccentricity, and PRL span in the worse-seeing eye (WE). Retrospective consecutive case series. Thirty-six patients with bilateral central field loss referred from the Toronto Western Hospital Retina Clinic, who had completed 2 consecutive fixation examinations on the same day. Fixation stability was recorded using the Nidek MP-1 microperimeter (Nidek Technologies Srl., Padova, Italy). For each fixation recording, the following parameters were retrieved: (i) 68.2% bivariate contour ellipse area (BCEA), (ii) PRL span (major and minor axes of the BCEA), (iii) PRL meridian (polar angle), and (iv) PRL eccentricity. Test-retest repeatability for each parameter was assessed using Bland-Altman plots to determine 95% limits of agreement. The mean difference between the fixation trial pairs and the 95% limits of agreement for fixation stability, PRL major axis, PRL minor axis, PRL meridian, and PRL eccentricity were 0.06 ± 0.47 log deg 2 , 0.05° ± 1.42°, 0.07° ± 0.63°, -0.44° ± 66.0°, and -0.23° ±1.56°, respectively. The fixation parameters in the WE showed robust repeatability, comparable to that of the BE as determined from previous studies. The WE's fixation repeatability should be considered in the interpretation of fixation outcome measures subsequent to treatment interventions. Crown Copyright © 2018. Published by Elsevier Inc. All rights reserved.

  6. Criticality of Low-Energy Protons in Single-Event Effects Testing of Highly-Scaled Technologies

    NASA Technical Reports Server (NTRS)

    Pellish, Jonathan Allen; Marshall, Paul W.; Rodbell, K. P.; Gordon, M. S.; LaBel, K. A.; Schwank, J. R.; Dodds, N. A.; Castaneda, C. M.; Berg, M. D.; Kim, H. S.; hide

    2014-01-01

    We report low-energy proton and alpha particle SEE data on a 32 nm silicon-on-insulator (SOI) complementary metal oxide semiconductor (CMOS) static random access memory (SRAM) that demonstrates the criticality of understanding and using low-energy protons for SEE testing of highly-scaled technologies

  7. Visual-motor response of crewmen during a simulated 90-day space mission as measured by the critical task battery

    NASA Technical Reports Server (NTRS)

    Allen, R. W.; Jex, H. R.

    1973-01-01

    In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in a space station simulator for 90 days and administered a tracking test battery. The battery included a clinical test (Critical Instability Task) designed to measure a subject's dynamic time delay, and a more conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The levels of each parameter span the range observed with professional pilots and astronaut candidates tested previously. The chamber environment caused no significant decrement on the average crewman's dynamic response behavior, and the subjects continued to improve slightly in their tracking skills during the 90-day confinement period.

  8. Total control: a critical analysis of mandatory HIV testing in U.S. prisons.

    PubMed

    Gagnon, Marilou; Jacob, Jean Daniel; Cormier, Luc

    2013-01-01

    The aim of this paper is to explore the relationship between mandatory HIV testing and the institutional management of inmates in U.S. prisons. Mandatory HIV testing has been largely overlooked by the nursing community even though it has important human rights and ethical implications. Drawing on the work of Goffman (1990) on the inner workings of total institutions, the present article critically examines the deployment of mandatory HIV testing in U.S. prisons. To set the stage, we define mandatory HIV testing and describe the methods of HIV testing currently used in U.S. prison settings. Then, we provide a brief overview of the concept of total institution and the mortification process. Finally, we expand on the relationship between mandatory HIV testing and much larger institutional objectives of total control, total structuring, total isolation, and separation of inmates from society (as summarized by Farrington, 1992). And lastly, we provide a brief discussion on the implications of mandatory HIV testing (as a method of HIV testing) from a nursing perspective.

  9. Investigating Cell Criticality

    NASA Astrophysics Data System (ADS)

    Serra, R.; Villani, M.; Damiani, C.; Graudenzi, A.; Ingrami, P.; Colacci, A.

    Random Boolean networks provide a way to give a precise meaning to the notion that living beings are in a critical state. Some phenomena which are observed in real biological systems (distribution of "avalanches" in gene knock-out experiments) can be modeled using random Boolean networks, and the results can be analytically proven to depend upon the Derrida parameter, which also determines whether the network is critical. By comparing observed and simulated data one can then draw inferences about the criticality of biological cells, although with some care because of the limited number of experimental observations. The relationship between the criticality of a single network and that of a set of interacting networks, which simulate a tissue or a bacterial colony, is also analyzed by computer simulations.

  10. Acoustic emission monitoring and critical failure identification of bridge cable damage

    NASA Astrophysics Data System (ADS)

    Li, Dongsheng; Ou, Jinping

    2008-03-01

    Acoustic emission (AE) characteristic parameters of bridge cable damage were obtained on tensile test. The testing results show that the AE parameter analysis method based on correlation figure of count, energy, duration time, amplitude and time can express the whole damage course, and can correctly judge the signal difference of broken wire and unbroken wire. It found the bridge cable AE characteristics aren't apparent before yield deformation, however they are increasing after yield deformation, at the time of breaking, and they reach to maximum. At last, the bridge cable damage evolution law is studied applying the AE characteristic parameter time series fractal theory. In the initial and middle stage of loading, the AE fractal value of bridge cable is unsteady. The fractal value reaches to the minimum at the critical point of failure. According to this changing law, it is approached how to make dynamic assessment and estimation of damage degrees.

  11. Space Qualification Test of a-Silicon Solar Cell Modules

    NASA Technical Reports Server (NTRS)

    Kim, Q.; Lawton, R. A.; Manion, S. J.; Okuno, J. O.; Ruiz, R. P.; Vu, D. T.; Vu, D. T.; Kayali, S. A.; Jeffrey, F. R.

    2004-01-01

    The basic requirements of solar cell modules for space applications are generally described in MIL-S-83576 for the specific needs of the USAF. However, the specifications of solar cells intended for use on space terrestrial applications are not well defined. Therefore, this qualifications test effort was concentrated on critical areas specific to the microseismometer probe which is intended to be included in the Mars microprobe programs. Parameters that were evaluated included performance dependence on: illuminating angles, terrestrial temperatures, lifetime, as well as impact landing conditions. Our qualification efforts were limited to these most critical areas of concern. Most of the tested solar cell modules have met the requirements of the program except the impact tests. Surprisingly, one of the two single PIN 2 x 1 amorphous solar cell modules continued to function even after the 80000G impact tests. The output power parameters, Pout, FF, Isc and Voc, of the single PIN amorphous solar cell module were found to be 3.14 mW, 0.40, 9.98 mA and 0.78 V, respectively. These parameters are good enough to consider the solar module as a possible power source for the microprobe seismometer. Some recommendations were made to improve the usefulness of the amorphous silicon solar cell modules in space terrestrial applications, based on the results obtained from the intensive short term lab test effort.

  12. Wireless remote monitoring of critical facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsai, Hanchung; Anderson, John T.; Liu, Yung Y.

    A method, apparatus, and system are provided for monitoring environment parameters of critical facilities. A Remote Area Modular Monitoring (RAMM) apparatus is provided for monitoring environment parameters of critical facilities. The RAMM apparatus includes a battery power supply and a central processor. The RAMM apparatus includes a plurality of sensors monitoring the associated environment parameters and at least one communication module for transmitting one or more monitored environment parameters. The RAMM apparatus is powered by the battery power supply, controlled by the central processor operating a wireless sensor network (WSN) platform when the facility condition is disrupted. The RAMM apparatusmore » includes a housing prepositioned at a strategic location, for example, where a dangerous build-up of contamination and radiation may preclude subsequent manned entrance and surveillance.« less

  13. Critical shear stress measurement of cohesive soils in streams: identifying device-dependent variability using an in-situ jet test device and conduit flume

    NASA Astrophysics Data System (ADS)

    Mahalder, B.; Schwartz, J. S.; Palomino, A.; Papanicolaou, T.

    2016-12-01

    Cohesive soil erodibility and threshold shear stress for stream bed and bank are dependent on both soil physical and geochemical properties in association with the channel vegetative conditions. These properties can be spatially variable therefore making critical shear stress measurement in cohesive soil challenging and leads to a need for a more comprehensive understanding of the erosional processes in streams. Several in-situ and flume-type test devices for estimating critical shear stress have been introduced by different researchers; however reported shear stress estimates per device vary widely in orders of magnitude. Advantages and disadvantages exist between these devices. Development of in-situ test devices leave the bed and/or bank material relatively undisturbed and can capture the variable nature of field soil conditions. However, laboratory flumes provide a means to control environmental conditions that can be quantify and tested. This study was conducted to observe differences in critical shear stress using jet tester and a well-controlled conduit flume. Soil samples were collected from the jet test locations and tested in a pressurized flume following standard operational procedure to calculate the critical shear stress. The results were compared using statistical data analysis (mean-separation ANOVA procedure) to identify possible differences. In addition to the device comparison, the mini jet device was used to measure critical shear stress across geologically diverse regions of Tennessee, USA. Statistical correlation between critical shear stress and the soil physical, and geochemical properties were completed identifying that geological origin plays a significant role in critical shear stress prediction for cohesive soils. Finally, the critical shear stress prediction equations using the jet test data were examined with possible suggestions to modify based on the flume test results.

  14. Validation of science virtual test to assess 8th grade students' critical thinking on living things and environmental sustainability theme

    NASA Astrophysics Data System (ADS)

    Rusyati, Lilit; Firman, Harry

    2017-05-01

    This research was motivated by the importance of multiple-choice questions that indicate the elements and sub-elements of critical thinking and implementation of computer-based test. The method used in this research was descriptive research for profiling the validation of science virtual test to measure students' critical thinking in junior high school. The participant is junior high school students of 8th grade (14 years old) while science teacher and expert as the validators. The instrument that used as a tool to capture the necessary data are sheet of an expert judgment, sheet of legibility test, and science virtual test package in multiple choice form with four possible answers. There are four steps to validate science virtual test to measure students' critical thinking on the theme of "Living Things and Environmental Sustainability" in 7th grade Junior High School. These steps are analysis of core competence and basic competence based on curriculum 2013, expert judgment, legibility test and trial test (limited and large trial test). The test item criterion based on trial test are accepted, accepted but need revision, and rejected. The reliability of the test is α = 0.747 that categorized as `high'. It means the test instruments used is reliable and high consistency. The validity of Rxy = 0.63 means that the validity of the instrument was categorized as `high' according to interpretation value of Rxy (correlation).

  15. The Impact of Cooperative Learning on Critical Thinking Test Scores of Associate's Degree Graduates in Southwest Virginia

    ERIC Educational Resources Information Center

    Hodges, James Gregory

    2013-01-01

    This study examined the impact that the teaching technique known as cooperative learning had on the changes between pre- and post-test scores on all sub-categories ("induction, deduction, analysis, evaluation, inference", and "total composite") associated with the "California Critical Thinking Skills Test" (CCTST) for…

  16. Framing Effects are Robust to Linguistic Disambiguation: A Critical Test of Contemporary Theory

    PubMed Central

    Chick, Christina F.; Reyna, Valerie F.; Corbin, Jonathan C.

    2015-01-01

    Theoretical accounts of risky choice framing effects assume that decision makers interpret framing options as extensionally equivalent, such that if 600 lives are at stake, saving 200 implies that 400 die. However, many scholars have argued that framing effects are caused, instead, by filling in pragmatically implied information. This linguistic ambiguity hypothesis is grounded in neo-Gricean pragmatics, information leakage, and schema theory. In two experiments, we conducted a critical test of the linguistic ambiguity hypothesis and its relation to framing. We controlled for this crucial implied information by disambiguating it using instructions and detailed examples, followed by multiple quizzes. After disambiguating missing information, we presented standard framing problems plus truncated versions, varying types of missing information. Truncations were also critical tests of prospect theory and fuzzy trace theory. Participants were not only college students, but also middle-aged adults (who showed similar results). Contrary to the ambiguity hypothesis, participants who interpreted missing information as complementary to stated information none the less showed robust framing effects. Although adding words like “at least” can change interpretations of framing information, this form of linguistic ambiguity is not necessary to observe risky choice framing effects. PMID:26348200

  17. Framing effects are robust to linguistic disambiguation: A critical test of contemporary theory.

    PubMed

    Chick, Christina F; Reyna, Valerie F; Corbin, Jonathan C

    2016-02-01

    Theoretical accounts of risky choice framing effects assume that decision makers interpret framing options as extensionally equivalent, such that if 600 lives are at stake, saving 200 implies that 400 die. However, many scholars have argued that framing effects are caused, instead, by filling in pragmatically implied information. This linguistic ambiguity hypothesis is grounded in neo-Gricean pragmatics, information leakage, and schema theory. In 2 experiments, we conducted critical tests of the linguistic ambiguity hypothesis and its relation to framing. We controlled for this crucial implied information by disambiguating it using instructions and detailed examples, followed by multiple quizzes. After disambiguating missing information, we presented standard framing problems plus truncated versions, varying types of missing information. Truncations were also critical tests of prospect theory and fuzzy trace theory. Participants were not only college students, but also middle-age adults (who showed similar results). Contrary to the ambiguity hypothesis, participants who interpreted missing information as complementary to stated information nonetheless showed robust framing effects. Although adding words like "at least" can change interpretations of framing information, this form of linguistic ambiguity is not necessary to observe risky choice framing effects. (c) 2016 APA, all rights reserved).

  18. The comparison between science virtual and paper based test in measuring grade 7 students’ critical thinking

    NASA Astrophysics Data System (ADS)

    Dhitareka, P. H.; Firman, H.; Rusyati, L.

    2018-05-01

    This research is comparing science virtual and paper-based test in measuring grade 7 students’ critical thinking based on Multiple Intelligences and gender. Quasi experimental method with within-subjects design is conducted in this research in order to obtain the data. The population of this research was all seventh grade students in ten classes of one public secondary school in Bandung. There were 71 students within two classes taken randomly became the sample in this research. The data are obtained through 28 questions with a topic of living things and environmental sustainability constructed based on eight critical thinking elements proposed by Inch then the questions provided in science virtual and paper-based test. The data was analysed by using paired-samples t test when the data are parametric and Wilcoxon signed ranks test when the data are non-parametric. In general comparison, the p-value of the comparison between science virtual and paper-based tests’ score is 0.506, indicated that there are no significance difference between science virtual and paper-based test based on the tests’ score. The results are furthermore supported by the students’ attitude result which is 3.15 from the scale from 1 to 4, indicated that they have positive attitudes towards Science Virtual Test.

  19. Dependence of the source performance on plasma parameters at the BATMAN test facility

    NASA Astrophysics Data System (ADS)

    Wimmer, C.; Fantz, U.

    2015-04-01

    The investigation of the dependence of the source performance (high jH-, low je) for optimum Cs conditions on the plasma parameters at the BATMAN (Bavarian Test MAchine for Negative hydrogen ions) test facility is desirable in order to find key parameters for the operation of the source as well as to deepen the physical understanding. The most relevant source physics takes place in the extended boundary layer, which is the plasma layer with a thickness of several cm in front of the plasma grid: the production of H-, its transport through the plasma and its extraction, inevitably accompanied by the co-extraction of electrons. Hence, a link of the source performance with the plasma parameters in the extended boundary layer is expected. In order to characterize electron and negative hydrogen ion fluxes in the extended boundary layer, Cavity Ring-Down Spectroscopy and Langmuir probes have been applied for the measurement of the H- density and the determination of the plasma density, the plasma potential and the electron temperature, respectively. The plasma potential is of particular importance as it determines the sheath potential profile at the plasma grid: depending on the plasma grid bias relative to the plasma potential, a transition in the plasma sheath from an electron repelling to an electron attracting sheath takes place, influencing strongly the electron fraction of the bias current and thus the amount of co-extracted electrons. Dependencies of the source performance on the determined plasma parameters are presented for the comparison of two source pressures (0.6 Pa, 0.45 Pa) in hydrogen operation. The higher source pressure of 0.6 Pa is a standard point of operation at BATMAN with external magnets, whereas the lower pressure of 0.45 Pa is closer to the ITER requirements (p ≤ 0.3 Pa).

  20. The relationship between students critical thinking measured by science virtual test and students logical thinking on eighth grade secondary school

    NASA Astrophysics Data System (ADS)

    Nurismawati, R.; Sanjaya, Y.; Rusyati, L.

    2018-05-01

    The aim of this study is to examine the relationship between students’ critical thinking skill and students’ logical thinking skill of Junior High School students in Tasikmalaya city. The respondent consists of 168 students from eighth grade at three public schools in Tasikmalaya City. Science Virtual Test and Test of Logical Thinking were used in this research study. Science virtual test instrument consist of 26 questions with 5 different topics. IBM SPSS 23.00 program was used for analysis of the data. By the findings; students’ critical thinking skill has significant differences in elements of generating purpose, embodying point of view, utilizing concept and making implication and consequence. By Post Hoc LSD Test, from those four elements, there are significant differences between concrete - transitional groups and transitional – concrete groups. There is positive and weak correlation between students’ critical thinking and students’ logical thinking attainment.

  1. Optimizing Muscle Parameters in Musculoskeletal Modeling Using Monte Carlo Simulations

    NASA Technical Reports Server (NTRS)

    Hanson, Andrea; Reed, Erik; Cavanagh, Peter

    2011-01-01

    Astronauts assigned to long-duration missions experience bone and muscle atrophy in the lower limbs. The use of musculoskeletal simulation software has become a useful tool for modeling joint and muscle forces during human activity in reduced gravity as access to direct experimentation is limited. Knowledge of muscle and joint loads can better inform the design of exercise protocols and exercise countermeasure equipment. In this study, the LifeModeler(TM) (San Clemente, CA) biomechanics simulation software was used to model a squat exercise. The initial model using default parameters yielded physiologically reasonable hip-joint forces. However, no activation was predicted in some large muscles such as rectus femoris, which have been shown to be active in 1-g performance of the activity. Parametric testing was conducted using Monte Carlo methods and combinatorial reduction to find a muscle parameter set that more closely matched physiologically observed activation patterns during the squat exercise. Peak hip joint force using the default parameters was 2.96 times body weight (BW) and increased to 3.21 BW in an optimized, feature-selected test case. The rectus femoris was predicted to peak at 60.1% activation following muscle recruitment optimization, compared to 19.2% activation with default parameters. These results indicate the critical role that muscle parameters play in joint force estimation and the need for exploration of the solution space to achieve physiologically realistic muscle activation.

  2. Using Bayesian regression to test hypotheses about relationships between parameters and covariates in cognitive models.

    PubMed

    Boehm, Udo; Steingroever, Helen; Wagenmakers, Eric-Jan

    2018-06-01

    An important tool in the advancement of cognitive science are quantitative models that represent different cognitive variables in terms of model parameters. To evaluate such models, their parameters are typically tested for relationships with behavioral and physiological variables that are thought to reflect specific cognitive processes. However, many models do not come equipped with the statistical framework needed to relate model parameters to covariates. Instead, researchers often revert to classifying participants into groups depending on their values on the covariates, and subsequently comparing the estimated model parameters between these groups. Here we develop a comprehensive solution to the covariate problem in the form of a Bayesian regression framework. Our framework can be easily added to existing cognitive models and allows researchers to quantify the evidential support for relationships between covariates and model parameters using Bayes factors. Moreover, we present a simulation study that demonstrates the superiority of the Bayesian regression framework to the conventional classification-based approach.

  3. Stress-Dilatancy of Cambria Sand for Triaxial Tests at High Pressures

    NASA Astrophysics Data System (ADS)

    Szypcio, Zenon

    2017-12-01

    In this paper, the stress-dilatancy relationship of Cambria sand for drained triaxial compression and extension tests at high stress level is investigated. The stress dilatancy relationship is obtained by use of frictional state theory and experimental tests data published in literature. It is shown that stress-dilatancy relationship is bilinear, described by three parameters of frictional state theory: critical frictional angle and two other parameters. It is accepted that critical friction angle is independent of confining pressure. The two additional parameters are strongly dependent on confining pressure and different for initial and advanced stages. The point at which the values of these parameters change is termed as Transformation Shear Point. This point is not simply visible either in stress ratio-strain or the volume strain-shear strain relationship which are traditionally shown in soil mechanics papers. Transformation Shear Point is very characteristic in stress ratio-plastic dilatancy plane. Thus, stress ratio- plastic dilatancy is very important for describing stress-strain behaviour of soils. The relationship shown in the paper can be used in soil modelling in the future.

  4. Summary of longitudinal stability and control parameters as determined from Space Shuttle Challenger flight test data

    NASA Technical Reports Server (NTRS)

    Suit, William T.

    1989-01-01

    Estimates of longitudinal stability and control parameters for the space shuttle were determined by applying a maximum likelihood parameter estimation technique to Challenger flight test data. The parameters for pitching moment coefficient, C(m sub alpha), (at different angles of attack), pitching moment coefficient, C(m sub delta e), (at different elevator deflections) and the normal force coefficient, C(z sub alpha), (at different angles of attack) describe 90 percent of the response to longitudinal inputs during Space Shuttle Challenger flights with C(m sub delta e) being the dominant parameter. The values of C(z sub alpha) were found to be input dependent for these tests. However, when C(z sub alpha) was set at preflight predictions, the values determined for C(m sub delta e) changed less than 10 percent from the values obtained when C(z sub alpha) was estimated as well. The preflight predictions for C(z sub alpha) and C(m sub alpha) are acceptable values, while the values of C(z sub delta e) should be about 30 percent less negative than the preflight predictions near Mach 1, and 10 percent less negative, otherwise.

  5. Scoping the parameter space for demo and the engineering test facility (ETF)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meier, Wayne R.

    1999-01-19

    In our IFE development plan, we have set a goal of building an Engineering Test Facility (ETF) for a total cost of $2B and a Demo for $3B. In Mike Campbell' s presentation at Madison, we included a viewgraph with an example Demo that had 80 to 250 MWe of net power and showed a plausible argument that it could cost less than $3B. In this memo, I examine the design space for the Demo and then briefly for the ETF. Instead of attempting to estimate the costs of the drivers, I pose the question in a way to definemore » R&D goals: As a function of key design and performance parameters, how much can the driver cost if the total facility cost is limited to the specified goal? The design parameters examined for the Demo included target gain, driver energy, driver efficiency, and net power output. For the ETF; the design parameters are target gain, driver energy, and target yield. The resulting graphs of allowable driver cost determine the goals that the driver R&D programs must seek to meet.« less

  6. How far are rheological parameters from amplitude sweep tests predictable using common physicochemical soil properties?

    NASA Astrophysics Data System (ADS)

    Stoppe, N.; Horn, R.

    2017-01-01

    A basic understanding of soil behavior on the mesoscale resp. macroscale (i.e. soil aggregates resp. bulk soil) requires knowledge of the processes at the microscale (i.e. particle scale), therefore rheological investigations of natural soils receive growing attention. In the present research homogenized and sieved (< 2 mm) samples from Marshland soils of the riparian zone of the River Elbe (North Germany) were analyzed with a modular compact rheometer MCR 300 (Anton Paar, Ostfildern, Germany) with a profiled parallel-plate measuring system. Amplitude sweep tests (AST) with controlled shear deformation were conducted to investigate the viscoelastic properties of the studied soils under oszillatory stress. The gradual depletion of microstructural stiffness during AST cannot only be characterized by the well-known rheological parameters G, G″ and tan δ but also by the dimensionless area parameter integral z, which quantifies the elasticity of microstructure. To discover the physicochemical parameters, which influences the microstructural stiffness, statistical tests were used taking the combined effects of these parameters into account. Although the influence of the individual factors varies depending on soil texture, the physicochemical features significantly affecting soil micro structure were identified. Based on the determined statistical relationships between rheological and physicochemical parameters, pedotransfer functions (PTF) have been developed, which allow a mathematical estimation of the rheological target value integral z. Thus, stabilizing factors are: soil organic matter, concentration of Ca2+, content of CaCO3 and pedogenic iron oxides; whereas the concentration of Na+ and water content represent structurally unfavorable factors.

  7. Critical adsorption profiles around a sphere and a cylinder in a fluid at criticality: Local functional theory

    NASA Astrophysics Data System (ADS)

    Yabunaka, Shunsuke; Onuki, Akira

    2017-09-01

    We study universal critical adsorption on a solid sphere and a solid cylinder in a fluid at bulk criticality, where preferential adsorption occurs. We use a local functional theory proposed by Fisher et al. [M. E. Fisher and P. G. de Gennes, C. R. Acad. Sci. Paris Ser. B 287, 207 (1978); M. E. Fisher and H. Au-Yang, Physica A 101, 255 (1980), 10.1016/0378-4371(80)90112-0]. We calculate the mean order parameter profile ψ (r ) , where r is the distance from the sphere center and the cylinder axis, respectively. The resultant differential equation for ψ (r ) is solved exactly around a sphere and numerically around a cylinder. A strong adsorption regime is realized except for very small surface field h1, where the surface order parameter ψ (a ) is determined by h1 and is independent of the radius a . If r considerably exceeds a , ψ (r ) decays as r-(1 +η ) for a sphere and r-(1 +η )/2 for a cylinder in three dimensions, where η is the critical exponent in the order parameter correlation at bulk criticality.

  8. Continuous-time adaptive critics.

    PubMed

    Hanselmann, Thomas; Noakes, Lyle; Zaknich, Anthony

    2007-05-01

    A continuous-time formulation of an adaptive critic design (ACD) is investigated. Connections to the discrete case are made, where backpropagation through time (BPTT) and real-time recurrent learning (RTRL) are prevalent. Practical benefits are that this framework fits in well with plant descriptions given by differential equations and that any standard integration routine with adaptive step-size does an adaptive sampling for free. A second-order actor adaptation using Newton's method is established for fast actor convergence for a general plant and critic. Also, a fast critic update for concurrent actor-critic training is introduced to immediately apply necessary adjustments of critic parameters induced by actor updates to keep the Bellman optimality correct to first-order approximation after actor changes. Thus, critic and actor updates may be performed at the same time until some substantial error build up in the Bellman optimality or temporal difference equation, when a traditional critic training needs to be performed and then another interval of concurrent actor-critic training may resume.

  9. Study of Critical Heat Flux and Two-Phase Pressure Drop Under Reduced Gravity

    NASA Technical Reports Server (NTRS)

    Abdollahian, Davood; Quintal, Joseph; Barez, Fred; Zahm, Jennifer; Lohr, Victor

    1996-01-01

    The design of the two-phase flow systems which are anticipated to be utilized in future spacecraft thermal management systems requires a knowledge of two-phase flow and heat transfer phenomena in reduced gravities. This program was funded by NASA headquarters in response to NRA-91-OSSA-17 and was managed by Lewis Research Center. The main objective of this program was to design and construct a two-phase test loop, and perform a series of normal gravity and aircraft trajectory experiments to study the effect of gravity on the Critical Heat Flux (CHF) and onset of instability. The test loop was packaged on two aircraft racks and was also instrumented to generate data for two-phase pressure drop. The normal gravity tests were performed with vertical up and downflow configurations to bound the effect of gravity on the test parameters. One set of aircraft trajectory tests was performed aboard the NASA DC-9 aircraft. These tests were mainly intended to evaluate the test loop and its operational performance under actual reduced gravity conditions, and to produce preliminary data for the test parameters. The test results were used to demonstrate the applicability of the normal gravity models for prediction of the two-phase friction pressure drop. It was shown that the two-phase friction multipliers for vertical upflow and reduced gravity conditions can be successfully predicted by the appropriate normal gravity models. Limited critical heat flux data showed that the measured CHF under reduced gravities are of the same order of magnitude as the test results with vertical upflow configuration. A simplified correlation was only successful in predicting the measured CHF for low flow rates. Instability tests with vertical upflow showed that flow becomes unstable and critical heat flux occurs at smaller powers when a parallel flow path exists. However, downflow tests and a single reduced gravity instability experiment indicated that the system actually became more stable with a

  10. Aerobic and Anaerobic Swimming Force Evaluation in One Single Test Session for Young Swimmers.

    PubMed

    de Barros Sousa, Filipe Antônio; Rodrigues, Natalia Almeida; Messias, Leonardo Henrique Dalcheco; Queiroz, Jair Borges; Manchado-Gobatto, Fulvia Barros; Gobatto, Claudio Alexandre

    2017-05-01

    This study aims to propose and validate the tethered swimming lactate minimum test (TSLacmin) estimating aerobic and anaerobic capacity in one single test session, using force as measurement parameter. 6 male and 6 female young swimmers (age=15.7±1.1 years; height=173.3±9.5 cm; weight=66.1±9.5 kg) performed 4 sessions comprising i) an all-out 30 s test and incremental test (TSLacmin); ii) 30 min of tethered swimming at constant intensity (2 sessions); iii) free-swimming time trials used to calculate critical velocity. Tethered swimming sessions used an acquisition system enabling maximum (Fmax) and mean (Fmean) force measurement and intensity variation. The tethered all-out test lasting 30 s resulted in hyperlactatemia of 7.9±2.0 mmol·l -1 . TSLacmin presented a 100% success applicability rate, which is equivalent to aerobic capacity in 75% of cases. TSLacmin intensity was 37.7±7.3 N, while maximum force in the all-out test was 105±27 N. Aerobic and anaerobic TSLacmin parameters were significantly related to free-swimming performance (r=-0.67 for 100 m and r=-0.80 for 200 m) and critical velocity (r=0.80). TSLacmin estimates aerobic capacity in most cases, and both aerobic and anaerobic force parameters are well related to critical velocity and free swimming performance. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Investigation of two and three parameter equations of state for cryogenic fluids

    NASA Technical Reports Server (NTRS)

    Jenkins, Susan L.; Majumdar, Alok K.; Hendricks, Robert C.

    1990-01-01

    Two-phase flows are a common occurrence in cryogenic engines and an accurate evaluation of the heat-transfer coefficient in two-phase flow is of significant importance in their analysis and design. The thermodynamic equation of state plays a key role in calculating the heat transfer coefficient which is a function of thermodynamic and thermophysical properties. An investigation has been performed to study the performance of two- and three-parameter equations of state to calculate the compressibility factor of cryogenic fluids along the saturation loci. The two-parameter equations considered here are van der Waals and Redlich-Kwong equations of state. The three-parameter equation represented here is the generalized Benedict-Webb-Rubin (BWR) equation of Lee and Kesler. Results have been compared with the modified BWR equation of Bender and the extended BWR equations of Stewart. Seven cryogenic fluids have been tested; oxygen, hydrogen, helium, nitrogen, argon, neon, and air. The performance of the generalized BWR equation is poor for hydrogen and helium. The van der Waals equation is found to be inaccurate for air near the critical point. For helium, all three equations of state become inaccurate near the critical point.

  12. Comparing Science Virtual and Paper-Based Test to Measure Students’ Critical Thinking based on VAK Learning Style Model

    NASA Astrophysics Data System (ADS)

    Rosyidah, T. H.; Firman, H.; Rusyati, L.

    2017-02-01

    This research was comparing virtual and paper-based test to measure students’ critical thinking based on VAK (Visual-Auditory-Kynesthetic) learning style model. Quasi experiment method with one group post-test only design is applied in this research in order to analyze the data. There was 40 eight grade students at one of public junior high school in Bandung becoming the sample in this research. The quantitative data was obtained through 26 questions about living thing and environment sustainability which is constructed based on the eight elements of critical thinking and be provided in the form of virtual and paper-based test. Based on analysis of the result, it is shown that within visual, auditory, and kinesthetic were not significantly difference in virtual and paper-based test. Besides, all result was supported by quistionnaire about students’ respond on virtual test which shows 3.47 in the scale of 4. Means that student showed positive respond in all aspet measured, which are interest, impression, and expectation.

  13. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients

    PubMed Central

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-01-01

    Abstract Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests. Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed. The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values. Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by

  14. Relation of thromboelastography parameters to conventional coagulation tests used to evaluate the hypercoagulable state of aged fracture patients.

    PubMed

    Liu, Chen; Guan, Zhao; Xu, Qinzhu; Zhao, Lei; Song, Ying; Wang, Hui

    2016-06-01

    Fractures are common among aged people, and rapid assessment of the coagulation status is important. The thromboelastography (TEG) test can give a series of coagulation parameters and has been widely used in clinics. In this research, we looked at fracture patients over 60 and compared their TEG results with those of healthy controls. Since there is a paucity of studies comparing TEG assessments with conventional coagulation tests, we aim to clarify the relationship between TEG values and the values given by conventional coagulation tests.Forty fracture patients (27 femur and 13 humerus) over 60 years old were included in the study. The change in their coagulation status was evaluated by TEG before surgery within 4 hours after the fracture. Changes in TEG parameters were analyzed compared with controls. Conventional coagulation test results for the patients, including activated partial thromboplastin time (APTT), international normalized ratio (INR), fibrinogen, and platelets, were also acquired, and correlation analysis was done with TEG parameters, measuring similar aspects of the coagulation cascade. In addition, the sensitivity and specificity of TEG parameters for detecting raised fibrinogen levels were also analyzed.The K (time to 20 mm clot amplitude) and R (reaction time) values of aged fracture patients were lower than controls. The values for angle, maximal amplitude (MA), and coagulation index (CI) were raised compared with controls, indicating a hypercoagulable state. Correlation analysis showed that there were significant positive correlations between fibrinogen and MA/angle, between platelets and MA, and between APTT and R as well. There was significant negative correlation between fibrinogen and K. In addition, K values have better sensitivity and specificity for detecting elevated fibrinogen concentration than angle and MA values.Aged fracture patients tend to be in a hypercoagulable state, and this could be effectively reflected by a TEG test

  15. Optimization of Equation of State and Burn Model Parameters for Explosives

    NASA Astrophysics Data System (ADS)

    Bergh, Magnus; Wedberg, Rasmus; Lundgren, Jonas

    2017-06-01

    A reactive burn model implemented in a multi-dimensional hydrocode can be a powerful tool for predicting non-ideal effects as well as initiation phenomena in explosives. Calibration against experiment is, however, critical and non-trivial. Here, a procedure is presented for calibrating the Ignition and Growth Model utilizing hydrocode simulation in conjunction with the optimization program LS-OPT. The model is applied to the explosive PBXN-109. First, a cylinder expansion test is presented together with a new automatic routine for product equation of state calibration. Secondly, rate stick tests and instrumented gap tests are presented. Data from these experiments are used to calibrate burn model parameters. Finally, we discuss the applicability and development of this optimization routine.

  16. A device for automatically measuring and supervising the critical care patient's urine output.

    PubMed

    Otero, Abraham; Palacios, Francisco; Akinfiev, Teodor; Fernández, Roemi

    2010-01-01

    Critical care units are equipped with commercial monitoring devices capable of sensing patients' physiological parameters and supervising the achievement of the established therapeutic goals. This avoids human errors in this task and considerably decreases the workload of the healthcare staff. However, at present there still is a very relevant physiological parameter that is measured and supervised manually by the critical care units' healthcare staff: urine output. This paper presents a patent-pending device capable of automatically recording and supervising the urine output of a critical care patient. A high precision scale is used to measure the weight of a commercial urine meter. On the scale's pan there is a support frame made up of Bosch profiles that isolates the scale from force transmission from the patient's bed, and guarantees that the urine flows properly through the urine meter input tube. The scale's readings are sent to a PC via Bluetooth where an application supervises the achievement of the therapeutic goals. The device is currently undergoing tests at a research unit associated with the University Hospital of Getafe in Spain.

  17. Model parameter learning using Kullback-Leibler divergence

    NASA Astrophysics Data System (ADS)

    Lin, Chungwei; Marks, Tim K.; Pajovic, Milutin; Watanabe, Shinji; Tung, Chih-kuan

    2018-02-01

    In this paper, we address the following problem: For a given set of spin configurations whose probability distribution is of the Boltzmann type, how do we determine the model coupling parameters? We demonstrate that directly minimizing the Kullback-Leibler divergence is an efficient method. We test this method against the Ising and XY models on the one-dimensional (1D) and two-dimensional (2D) lattices, and provide two estimators to quantify the model quality. We apply this method to two types of problems. First, we apply it to the real-space renormalization group (RG). We find that the obtained RG flow is sufficiently good for determining the phase boundary (within 1% of the exact result) and the critical point, but not accurate enough for critical exponents. The proposed method provides a simple way to numerically estimate amplitudes of the interactions typically truncated in the real-space RG procedure. Second, we apply this method to the dynamical system composed of self-propelled particles, where we extract the parameter of a statistical model (a generalized XY model) from a dynamical system described by the Viscek model. We are able to obtain reasonable coupling values corresponding to different noise strengths of the Viscek model. Our method is thus able to provide quantitative analysis of dynamical systems composed of self-propelled particles.

  18. Item Parameter Invariance of the Kaufman Adolescent and Adult Intelligence Test across Male and Female Samples

    ERIC Educational Resources Information Center

    Immekus, Jason C.; Maller, Susan J.

    2009-01-01

    The Kaufman Adolescent and Adult Intelligence Test (KAIT[TM]) is an individually administered test of intelligence for individuals ranging in age from 11 to 85+ years. The item response theory-likelihood ratio procedure, based on the two-parameter logistic model, was used to detect differential item functioning (DIF) in the KAIT across males and…

  19. Quantum critical fluctuations in disordered d-wave superconductors.

    PubMed

    Meyer, Julia S; Gornyi, Igor V; Altland, Alexander

    2003-03-14

    To explain the strong quasiparticle damping in the cuprates, Sachdev and collaborators proposed to couple the system to a critically fluctuating id(xy)- or is-order parameter mode. Here we generalize the approach to the presence of static disorder. In the id case, the order parameter dynamics becomes diffusive, but otherwise much of the phenomenology of the clean case remains intact. In contrast, the interplay of disorder and is-order parameter fluctuations leads to a secondary superconductor transition, with a critical temperature exponentially sensitive to the impurity concentration.

  20. Continuous excitation chlorophyll fluorescence parameters: a review for practitioners.

    PubMed

    Banks, Jonathan M

    2017-08-01

    This review introduces, defines and critically reviews a number of chlorophyll fluorescence parameters with specific reference to those derived from continuous excitation chlorophyll fluorescence. A number of common issues and criticisms are addressed. The parameters fluorescence origin (F0) and the performance indices (PI) are discussed as examples. This review attempts to unify definitions for the wide range of parameters available for measuring plant vitality, facilitating their calculation and use. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. An Evaluation of One- and Three-Parameter Logistic Tailored Testing Procedures for Use with Small Item Pools.

    ERIC Educational Resources Information Center

    McKinley, Robert L.; Reckase, Mark D.

    A two-stage study was conducted to compare the ability estimates yielded by tailored testing procedures based on the one-parameter logistic (1PL) and three-parameter logistic (3PL) models. The first stage of the study employed real data, while the second stage employed simulated data. In the first stage, response data for 3,000 examinees were…

  2. Using a Functional Simulation of Crisis Management to Test the C2 Agility Model Parameters on Key Performance Variables

    DTIC Science & Technology

    2013-06-01

    1 18th ICCRTS Using a Functional Simulation of Crisis Management to Test the C2 Agility Model Parameters on Key Performance Variables...AND SUBTITLE Using a Functional Simulation of Crisis Management to Test the C2 Agility Model Parameters on Key Performance Variables 5a. CONTRACT...command in crisis management. C2 Agility Model Agility can be conceptualized at a number of different levels; for instance at the team

  3. A criticality result for polycycles in a family of quadratic reversible centers

    NASA Astrophysics Data System (ADS)

    Rojas, D.; Villadelprat, J.

    2018-06-01

    We consider the family of dehomogenized Loud's centers Xμ = y (x - 1)∂x + (x + Dx2 + Fy2)∂y, where μ = (D , F) ∈R2, and we study the number of critical periodic orbits that emerge or disappear from the polycycle at the boundary of the period annulus. This number is defined exactly the same way as the well-known notion of cyclicity of a limit periodic set and we call it criticality. The previous results on the issue for the family {Xμ , μ ∈R2 } distinguish between parameters with criticality equal to zero (regular parameters) and those with criticality greater than zero (bifurcation parameters). A challenging problem not tackled so far is the computation of the criticality of the bifurcation parameters, which form a set ΓB of codimension 1 in R2. In the present paper we succeed in proving that a subset of ΓB has criticality equal to one.

  4. Flight Test of Orthogonal Square Wave Inputs for Hybrid-Wing-Body Parameter Estimation

    NASA Technical Reports Server (NTRS)

    Taylor, Brian R.; Ratnayake, Nalin A.

    2011-01-01

    As part of an effort to improve emissions, noise, and performance of next generation aircraft, it is expected that future aircraft will use distributed, multi-objective control effectors in a closed-loop flight control system. Correlation challenges associated with parameter estimation will arise with this expected aircraft configuration. The research presented in this paper focuses on addressing the correlation problem with an appropriate input design technique in order to determine individual control surface effectiveness. This technique was validated through flight-testing an 8.5-percent-scale hybrid-wing-body aircraft demonstrator at the NASA Dryden Flight Research Center (Edwards, California). An input design technique that uses mutually orthogonal square wave inputs for de-correlation of control surfaces is proposed. Flight-test results are compared with prior flight-test results for a different maneuver style.

  5. Predicting Fatigue and Psychophysiological Test Performance from Speech for Safety-Critical Environments.

    PubMed

    Baykaner, Khan Richard; Huckvale, Mark; Whiteley, Iya; Andreeva, Svetlana; Ryumin, Oleg

    2015-01-01

    Automatic systems for estimating operator fatigue have application in safety-critical environments. A system which could estimate level of fatigue from speech would have application in domains where operators engage in regular verbal communication as part of their duties. Previous studies on the prediction of fatigue from speech have been limited because of their reliance on subjective ratings and because they lack comparison to other methods for assessing fatigue. In this paper, we present an analysis of voice recordings and psychophysiological test scores collected from seven aerospace personnel during a training task in which they remained awake for 60 h. We show that voice features and test scores are affected by both the total time spent awake and the time position within each subject's circadian cycle. However, we show that time spent awake and time-of-day information are poor predictors of the test results, while voice features can give good predictions of the psychophysiological test scores and sleep latency. Mean absolute errors of prediction are possible within about 17.5% for sleep latency and 5-12% for test scores. We discuss the implications for the use of voice as a means to monitor the effects of fatigue on cognitive performance in practical applications.

  6. Predicting Fatigue and Psychophysiological Test Performance from Speech for Safety-Critical Environments

    PubMed Central

    Baykaner, Khan Richard; Huckvale, Mark; Whiteley, Iya; Andreeva, Svetlana; Ryumin, Oleg

    2015-01-01

    Automatic systems for estimating operator fatigue have application in safety-critical environments. A system which could estimate level of fatigue from speech would have application in domains where operators engage in regular verbal communication as part of their duties. Previous studies on the prediction of fatigue from speech have been limited because of their reliance on subjective ratings and because they lack comparison to other methods for assessing fatigue. In this paper, we present an analysis of voice recordings and psychophysiological test scores collected from seven aerospace personnel during a training task in which they remained awake for 60 h. We show that voice features and test scores are affected by both the total time spent awake and the time position within each subject’s circadian cycle. However, we show that time spent awake and time-of-day information are poor predictors of the test results, while voice features can give good predictions of the psychophysiological test scores and sleep latency. Mean absolute errors of prediction are possible within about 17.5% for sleep latency and 5–12% for test scores. We discuss the implications for the use of voice as a means to monitor the effects of fatigue on cognitive performance in practical applications. PMID:26380259

  7. The Prediction of Item Parameters Based on Classical Test Theory and Latent Trait Theory

    ERIC Educational Resources Information Center

    Anil, Duygu

    2008-01-01

    In this study, the prediction power of the item characteristics based on the experts' predictions on conditions try-out practices cannot be applied was examined for item characteristics computed depending on classical test theory and two-parameters logistic model of latent trait theory. The study was carried out on 9914 randomly selected students…

  8. Phytoplankton abundance and structural parameters of the critically endangered protected area Vaya Lake (Bulgaria).

    PubMed

    Dimitrova, Ralits; Nenova, Elena; Uzunov, Blagoy; Shishiniova, Maria; Stoyneva, Maya

    2014-09-03

    Vaya (Ramsar site, protected area and Natura 2000 site) is the biggest natural lake in Bulgaria and the shallowest Black Sea coastal lake, which during the last decades has undergone significant changes and was included as critically endangered in the Red List of Bulgarian Wetlands. Our studies were conducted during the summer and autumn months of three years - 2004-2006. The paper presents results on the phytoplankton abundance (numbers, biomass and carbon content) in combination with the indices of species diversity, evenness and dominance. Phytoplankton abundance was extremely high (average values of 1135 × 10 6 cells/L for the quantity and of 46 mg/L for the biomass) and increased in the end of the studied period (years 2005-2006), when decrease of species diversity and increase of the dominance index values were detected. The carbon content of the phytoplankton was at an average value of 9.7 mg/L and also increased from 2004 to 2006. Cyanoprokaryota dominated in the formation of the total carbon content of the phytoplankton, in its numbers (88%-97.8%), and in the biomass (62%-87.9%). All data on phytoplankton abundance and structural parameters in Vaya confirm the hypertrophic status of the lake and reflect the general negative trend in its development.

  9. Assessing the performance of community-available global MHD models using key system parameters and empirical relationships

    NASA Astrophysics Data System (ADS)

    Gordeev, E.; Sergeev, V.; Honkonen, I.; Kuznetsova, M.; Rastätter, L.; Palmroth, M.; Janhunen, P.; Tóth, G.; Lyon, J.; Wiltberger, M.

    2015-12-01

    Global magnetohydrodynamic (MHD) modeling is a powerful tool in space weather research and predictions. There are several advanced and still developing global MHD (GMHD) models that are publicly available via Community Coordinated Modeling Center's (CCMC) Run on Request system, which allows the users to simulate the magnetospheric response to different solar wind conditions including extraordinary events, like geomagnetic storms. Systematic validation of GMHD models against observations still continues to be a challenge, as well as comparative benchmarking of different models against each other. In this paper we describe and test a new approach in which (i) a set of critical large-scale system parameters is explored/tested, which are produced by (ii) specially designed set of computer runs to simulate realistic statistical distributions of critical solar wind parameters and are compared to (iii) observation-based empirical relationships for these parameters. Being tested in approximately similar conditions (similar inputs, comparable grid resolution, etc.), the four models publicly available at the CCMC predict rather well the absolute values and variations of those key parameters (magnetospheric size, magnetic field, and pressure) which are directly related to the large-scale magnetospheric equilibrium in the outer magnetosphere, for which the MHD is supposed to be a valid approach. At the same time, the models have systematic differences in other parameters, being especially different in predicting the global convection rate, total field-aligned current, and magnetic flux loading into the magnetotail after the north-south interplanetary magnetic field turning. According to validation results, none of the models emerges as an absolute leader. The new approach suggested for the evaluation of the models performance against reality may be used by model users while planning their investigations, as well as by model developers and those interesting to quantitatively

  10. Influence of solid-liquid separation method parameters employed in soil leaching tests on apparent metal concentration.

    PubMed

    Imoto, Yukari; Yasutaka, Tetsuo; Someya, Masayuki; Higashino, Kazuo

    2018-05-15

    Soil leaching tests are commonly used to evaluate the leachability of hazardous materials, such as heavy metals, from the soil. Batch leaching tests often enhance soil colloidal mobility and may require solid-liquid separation procedures to remove excess soil particles. However, batch leaching test results depend on particles that can pass through a 0.45μm membrane filter and are influenced by test parameters such as centrifugal intensity and filtration volume per filter. To evaluate these parameters, we conducted batch leaching experiments using metal-contaminated soils and focused on the centrifugal intensity and filtration volume per filter used in solid-liquid separation methods currently employed in standard leaching tests. Our experiments showed that both centrifugal intensity and filtration volume per filter affected the reproducibility of batch leaching tests for some soil types. The results demonstrated that metal concentrations in the filtrates significantly differed according to the centrifugal intensity when it was 3000 g for 2h or less. Increased filtration volume per filter led to significant decreases in filtrate metal concentrations when filter cakes formed during filtration. Comparison of the filtration tests using 0.10 and 0.45μm membrane filters showed statistically significant differences in turbidity and metal concentration. These findings suggest that colloidal particles were not adequately removed from the extract and contributed substantially to the apparent metal concentrations in the leaching test of soil containing colloidal metals. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  11. Biological and analytical variations of 16 parameters related to coagulation screening tests and the activity of coagulation factors.

    PubMed

    Chen, Qian; Shou, Weiling; Wu, Wei; Guo, Ye; Zhang, Yujuan; Huang, Chunmei; Cui, Wei

    2015-04-01

    To accurately estimate longitudinal changes in individuals, it is important to take into consideration the biological variability of the measurement. The few studies available on the biological variations of coagulation parameters are mostly outdated. We confirmed the published results using modern, fully automated methods. Furthermore, we added data for additional coagulation parameters. At 8:00 am, 12:00 pm, and 4:00 pm on days 1, 3, and 5, venous blood was collected from 31 healthy volunteers. A total of 16 parameters related to coagulation screening tests as well as the activity of coagulation factors were analyzed; these included prothrombin time, fibrinogen (Fbg), activated partial thromboplastin time, thrombin time, international normalized ratio, prothrombin time activity, activated partial thromboplastin time ratio, fibrin(-ogen) degradation products, as well as the activity of factor II, factor V, factor VII, factor VIII, factor IX, and factor X. All intraindividual coefficients of variation (CVI) values for the parameters of the screening tests (except Fbg) were less than 5%. Conversely, the CVI values for the activity of coagulation factors were all greater than 5%. In addition, we calculated the reference change value to determine whether a significant difference exists between two test results from the same individual. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  12. Estimation of genetic parameters and response to selection for a continuous trait subject to culling before testing.

    PubMed

    Arnason, T; Albertsdóttir, E; Fikse, W F; Eriksson, S; Sigurdsson, A

    2012-02-01

    The consequences of assuming a zero environmental covariance between a binary trait 'test-status' and a continuous trait on the estimates of genetic parameters by restricted maximum likelihood and Gibbs sampling and on response from genetic selection when the true environmental covariance deviates from zero were studied. Data were simulated for two traits (one that culling was based on and a continuous trait) using the following true parameters, on the underlying scale: h² = 0.4; r(A) = 0.5; r(E) = 0.5, 0.0 or -0.5. The selection on the continuous trait was applied to five subsequent generations where 25 sires and 500 dams produced 1500 offspring per generation. Mass selection was applied in the analysis of the effect on estimation of genetic parameters. Estimated breeding values were used in the study of the effect of genetic selection on response and accuracy. The culling frequency was either 0.5 or 0.8 within each generation. Each of 10 replicates included 7500 records on 'test-status' and 9600 animals in the pedigree file. Results from bivariate analysis showed unbiased estimates of variance components and genetic parameters when true r(E) = 0.0. For r(E) = 0.5, variance components (13-19% bias) and especially (50-80%) were underestimated for the continuous trait, while heritability estimates were unbiased. For r(E) = -0.5, heritability estimates of test-status were unbiased, while genetic variance and heritability of the continuous trait together with were overestimated (25-50%). The bias was larger for the higher culling frequency. Culling always reduced genetic progress from selection, but the genetic progress was found to be robust to the use of wrong parameter values of the true environmental correlation between test-status and the continuous trait. Use of a bivariate linear-linear model reduced bias in genetic evaluations, when data were subject to culling. © 2011 Blackwell Verlag GmbH.

  13. Pendulum test measure correlates with gait parameters in children with cerebral palsy.

    PubMed

    Lotfian, M; Mirbagheri, M M; Kharazi, M R; Dadashi, F; Nourian, R; Irani, A; Mirbagheri, A

    2016-08-01

    Individuals with cerebral palsy (CP) usually suffer from different impairments including gait impairment and spasticity. Spastic hypertonia is a defining feature of spasticity and manifests as a mechanical abnormality. The objective of this study was to determine the relationship between spastic hypertonia and gait impairments in spastic children with CP, addressing an important controversial issue. Spastic hypertonia was quantified using the pendulum test. The gait impairments were evaluated using the motion capture system in a gait laboratory. Our results showed significant correlations among gait parameters; i.e. walking speed, step length, and the pendulum test measures. This indicates that neuromuscular abnormalities are associated with spasticity and may contribute to gait impairments. The clinical implication is that the impaired gait in children with CP may be improved with the treatment of neuromuscular abnormalities.

  14. Computerized Classification Testing under the One-Parameter Logistic Response Model with Ability-Based Guessing

    ERIC Educational Resources Information Center

    Wang, Wen-Chung; Huang, Sheng-Yun

    2011-01-01

    The one-parameter logistic model with ability-based guessing (1PL-AG) has been recently developed to account for effect of ability on guessing behavior in multiple-choice items. In this study, the authors developed algorithms for computerized classification testing under the 1PL-AG and conducted a series of simulations to evaluate their…

  15. Multi-parameter fibre Bragg grating sensor-array for thermal vacuum cycling test

    NASA Astrophysics Data System (ADS)

    Cheng, L.; Ahlers, B.; Toet, P.; Casarosa, G.; Appolloni, M.

    2017-11-01

    Fibre Bragg Grating (FBG) sensor systems based on optical fibres are gaining interest in space applications. Studies on Structural Health Monitoring (SHM) of the reusable launchers using FBG sensors have been carried out in the Future European Space Transportation Investigations Programme (FESTIP). Increasing investment in the development on FBG sensor applications is foreseen for the Future Launchers Preparatory Programme (FLPP). TNO has performed different SHM measurements with FBGs including on the VEGA interstage [1, 2] in 2006. Within the current project, a multi-parameter FBG sensor array demonstrator system for temperature and strain measurements is designed, fabricated and tested under ambient as well as Thermal Vacuum (TV) conditions in a TV chamber of the European Space Agency (ESA), ESTEC site. The aim is the development of a multi-parameters measuring system based on FBG technology for space applications. During the TV tests of a Space Craft (S/C) or its subsystems, thermal measurements, as well as strain measurements are needed by the engineers in order to verify their prediction and to validate their models. Because of the dimensions of the test specimen and the accuracy requested to the measurement, a large number of observation/measuring points are needed. Conventional sensor systems require a complex routing of the cables connecting the sensors to their acquisition unit. This will add extra weight to the construction under test. FBG sensors are potentially light-weight and can easily be multiplexed in an array configuration. The different tasks comply of a demonstrator system design; its component selection, procurement, manufacturing and finally its assembly. The temperature FBG sensor is calibrated in a dedicated laboratory setup down to liquid nitrogen (LN2) temperature at TNO. A temperature-wavelength calibration curve is generated. After a test programme definition a setup in thermal vacuum is realised at ESA premises including a mechanical

  16. Benchmark Calibration Tests Completed for Stirling Convertor Heater Head Life Assessment

    NASA Technical Reports Server (NTRS)

    Krause, David L.; Halford, Gary R.; Bowman, Randy R.

    2005-01-01

    A major phase of benchmark testing has been completed at the NASA Glenn Research Center (http://www.nasa.gov/glenn/), where a critical component of the Stirling Radioisotope Generator (SRG) is undergoing extensive experimentation to aid the development of an analytical life-prediction methodology. Two special-purpose test rigs subjected SRG heater-head pressure-vessel test articles to accelerated creep conditions, using the standard design temperatures to stay within the wall material s operating creep-response regime, but increasing wall stresses up to 7 times over the design point. This resulted in well-controlled "ballooning" of the heater-head hot end. The test plan was developed to provide critical input to analytical parameters in a reasonable period of time.

  17. Guidelines for Proof Test Analysis

    NASA Technical Reports Server (NTRS)

    Chell, G. G.; McClung, R. C.; Kuhlman, C. J.; Russell, D. A.; Garr, K.; Donnelly, B.

    1999-01-01

    These guidelines integrate state-of-the-art elastic-plastic fracture mechanics (EPFM) and proof test implementation issues into a comprehensive proof test analysis procedure in the form of a road map which identifies the types of data, fracture mechanics based parameters, and calculations needed to perform flaw screening and minimum proof load analyses of fracture critical components. Worked examples are presented to illustrate the application of the road map to proof test analysis. The state-of-the art fracture technology employed in these guidelines is based on the EPFM parameter, J, and a pictorial representation of a J fracture analysis, called the failure assessment diagram (FAD) approach. The recommended fracture technology is validated using finite element J results, and laboratory and hardware fracture test results on the nickel-based superalloy Inconel 718, the aluminum alloy 2024-T3511, and ferritic pressure vessel steels. In all cases the laboratory specimens and hardware failed by ductile mechanisms. Advanced proof test analyses involving probability analysis and multiple-cycle proof testing (MCPT) are addressed. Finally, recommendations are provided on how to account for the effects of the proof test overload on subsequent service fatigue and fracture behaviors.

  18. The 3-min all-out test is valid for determining critical power but not anaerobic work capacity in tethered running

    PubMed Central

    2018-01-01

    The purpose of the study was to investigate if the 3-min all-out test (3MT) is valid for obtaining critical power intensity (CP) and the amount of work that can be performed above CP (W’) on non-motorized treadmills in tethered running. Eight physically active individuals (24 ± 3 years; 78.3 ± 8.7 kg; 179 ± 5 cm; 9.0 ± 2.5% body fat) performed four different efforts at constant intensity to exhaustion in order to determine CP and W’. The mechanical power values obtained were subsequently plotted with their corresponding time to exhaustion (limit time) for application of three mathematical models: power hyperbolic versus time limit (Hyp), linear power versus 1/time (P vs 1/t) and linear work versus time limit (Ԏ vs t). The 3MT test was carried out on the last day to determine end power (EP) and anaerobic capacity (WEP) using this methodology. EP value of 181.7 ± 52 was similar (p = 0.486) to 178.2 ± 61 (CP Hyp), 191.4 ± 55 (Ԏ vs t) and 188.3 ± 55 (P vs 1/t). WEP value of 17.9 ± 4.8 was not similar (p = 0.000) to 50.2 ± 15.3 (CP Hyp), 44.8 ± 8.7 (Ԏ vs t) and 45.5 ± 8.4 (P vs 1/t). Positive results (r = 0.78–0.98 and ICC = 0.88–0.99) of Pearson correlation and intraclass correlation (ICC–absolute agreement) were found for aerobic applications of conventional CP and 3MT. For anaerobic data, only the three models of conventional CP were correlated (r = 0.76–0.93); however, W’ from the three models was not correlated with WEP (r = 0.37–0.52). The results of this study suggest that 3MT in tethered running on non-motorized treadmills is a valid test for estimating CP aerobic parameters in a single day of application but not anaerobic parameters of W’. PMID:29444141

  19. Several Modified Goodness-Of-Fit Tests for the Cauchy Distribution with Unknown Scale and Location Parameters

    DTIC Science & Technology

    1994-03-01

    labels of a, which is called significance levels. The hypothesis tests are done based on the a levels . The maximum probabilities of making type II error...critical values at specific a levels . This procedure is done for each of the 50,000 samples. The number of the samples passing each test at those specific... a levels is counted. The ratio of the number of accepted samples to 50,000 gives the percentage point. Then, subtracting that value from one would

  20. Usefulness and diagnostic value of the NEMA parameter combined with other selected bedside tests for prediction of difficult intubation.

    PubMed

    Torres, Kamil; Błoński, Marcin; Pietrzyk, Łukasz; Piasecka-Twaróg, Małgorzata; Maciejewski, Ryszard; Torres, Anna

    2017-02-01

    To assess the usefulness of the new NEMA (Neck Circumference Minus Acromion-Acromion Distance) parameter, in preoperative identification of patients' difficult intubation and compare it with other commonly used scales and tests. Prospective study. District Specialist Hospital of Lublin, Poland. Six hundreds twenty-nine patients underwent nonemergency surgical interventions. The NEMA parameter was confronted with: Modified Mallampati classification, TMD, RHTMD, NC, MPND, SMD, I-I D, A-AD, and medical history of difficult intubation and diagnosed obstructive sleep apnea syndrome or snoring. Higher medians of NEMA and Mallampati parameters were reported in patients with difficult intubation. AUC for Mallampati parameter was 0.733 while the NEMA parameter's AUC was 0.625. Sensitivity and specificity for Mallampati and NEMA parameter were respectively 0.79; 0.55 and 0.42; 0.75. Significantly higher MPN, RHTMD, Mallampati, and NEMA parameter were observed in patients in whom the BURP was used. Easy intubation occurs more frequently in patients with a history of OSAS or snoring than in those with difficult intubation. It seems that none of the known bedside tests for predicting difficult intubation have a discriminating power sufficient for clinicians. Our study draws attention to a novel parameter, called NEMA, which appears to be a strong predictor of DEI, especially in combination with the Mallampati scale. Copyright © 2016 Elsevier Inc. All rights reserved.

  1. Buckling of thermally fluctuating spherical shells: Parameter renormalization and thermally activated barrier crossing

    NASA Astrophysics Data System (ADS)

    Baumgarten, Lorenz; Kierfeld, Jan

    2018-05-01

    We study the influence of thermal fluctuations on the buckling behavior of thin elastic capsules with spherical rest shape. Above a critical uniform pressure, an elastic capsule becomes mechanically unstable and spontaneously buckles into a shape with an axisymmetric dimple. Thermal fluctuations affect the buckling instability by two mechanisms. On the one hand, thermal fluctuations can renormalize the capsule's elastic properties and its pressure because of anharmonic couplings between normal displacement modes of different wavelengths. This effectively lowers its critical buckling pressure [Košmrlj and Nelson, Phys. Rev. X 7, 011002 (2017), 10.1103/PhysRevX.7.011002]. On the other hand, buckled shapes are energetically favorable already at pressures below the classical buckling pressure. At these pressures, however, buckling requires to overcome an energy barrier, which only vanishes at the critical buckling pressure. In the presence of thermal fluctuations, the capsule can spontaneously overcome an energy barrier of the order of the thermal energy by thermal activation already at pressures below the critical buckling pressure. We revisit parameter renormalization by thermal fluctuations and formulate a buckling criterion based on scale-dependent renormalized parameters to obtain a temperature-dependent critical buckling pressure. Then we quantify the pressure-dependent energy barrier for buckling below the critical buckling pressure using numerical energy minimization and analytical arguments. This allows us to obtain the temperature-dependent critical pressure for buckling by thermal activation over this energy barrier. Remarkably, both parameter renormalization and thermal activation lead to the same parameter dependence of the critical buckling pressure on temperature, capsule radius and thickness, and Young's modulus. Finally, we study the combined effect of parameter renormalization and thermal activation by using renormalized parameters for the energy

  2. Critical phenomena at the threshold of immediate merger in binary black hole systems: The extreme mass ratio case

    NASA Astrophysics Data System (ADS)

    Gundlach, Carsten; Akcay, Sarp; Barack, Leor; Nagar, Alessandro

    2012-10-01

    In numerical simulations of black hole binaries, Pretorius and Khurana [Classical Quantum Gravity 24, S83 (2007)CQGRDG0264-938110.1088/0264-9381/24/12/S07] have observed critical behavior at the threshold between scattering and immediate merger. The number of orbits scales as n≃-γln⁡|p-p*| along any one-parameter family of initial data such that the threshold is at p=p*. Hence, they conjecture that in ultrarelativistic collisions almost all the kinetic energy can be converted into gravitational waves if the impact parameter is fine-tuned to the threshold. As a toy model for the binary, they consider the geodesic motion of a test particle in a Kerr black hole spacetime, where the unstable circular geodesics play the role of critical solutions, and calculate the critical exponent γ. Here, we incorporate radiation reaction into this model using the self-force approximation. The critical solution now evolves adiabatically along a sequence of unstable circular geodesic orbits under the effect of the self-force. We confirm that almost all the initial energy and angular momentum are radiated on the critical solution. Our calculation suggests that, even for infinite initial energy, this happens over a finite number of orbits given by n∞≃0.41/η, where η is the (small) mass ratio. We derive expressions for the time spent on the critical solution, number of orbits and radiated energy as functions of the initial energy and impact parameter.

  3. Photobiomodulation Therapy on Physiological and Performance Parameters During Running Tests: Dose-Response Effects.

    PubMed

    Dellagrana, Rodolfo André; Rossato, Mateus; Sakugawa, Raphael Luiz; Baroni, Bruno Mafredini; Diefenthaeler, Fernando

    2018-02-22

    This study was aimed at verifying effects of photobiomodulation therapy (PBMT) with different energy doses (15, 30, and 60 J per site) on physiological and performance parameters during running tests. Fifteen male recreational runners participated in a crossover, randomised, double-blind, and placebo-controlled trial. They performed testing protocol in 5 sessions with different treatments: control, placebo, and PBMT with 15, 30 or 60 J per site (14 sites in each lower limb). Physiological and performance variables were assessed during submaximal (at 8 km·h-1 and 9 km·h-1) and maximal running tests. PBMT with 30 J significantly (p<0.05) improved running economy (RE) at 8 and 9 km·h-1 (3.01% and 3.03%, respectively), rate of perceived exertion (RPE) at 8 km·h-1 (7.86%), velocity at VO2MAX (3.07%), peak of velocity (PV) (1.49%), and total time to exhaustion (TTE) (3.41%) compared to placebo. PBMT with 15 J improved RE at 9 km·h-1 (2.98%), RPE at 8 km·h-1 (4.80%), PV (1.33%), TTE (3.06%), and total distance (4.01%) compared to the placebo; while PBMT with 60 J only increased RE at 9 km·h-1 (3.87%) compared to placebo. All PBMT doses positively affected physiological and/or performance parameters; however magnitude-based inference reported that PBMT applied with 30 J led to more beneficial effects than 15 J and 60 J.

  4. Swimming Training Assessment: The Critical Velocity and the 400-m Test for Age-Group Swimmers.

    PubMed

    Zacca, Rodrigo; Fernandes, Ricardo Jorge P; Pyne, David B; Castro, Flávio Antônio de S

    2016-05-01

    To verify the metabolic responses of oxygen consumption (V[Combining Dot Above]O2), heart rate (HR), blood lactate concentrations [La], and rate of perceived exertion (RPE) when swimming at an intensity corresponding to the critical velocity (CV) assessed by a 4-parameter model (CV4par), and to check the reliability when using only a single 400-m maximal front crawl bout (T400) for CV4par assessment in age-group swimmers. Ten age-group swimmers (14-16 years old) performed 50-, 100-, 200-, 400- (T400), 800-, and 1,500-m maximal front crawl bouts to calculate CV4par. V[Combining Dot Above]O2, HR, [La], and RPE were measured immediately after bouts. Swimmers then performed 3 × 10-minute front crawl (45 seconds rest) at CV4par. V[Combining Dot Above]O2, HR, [La], and RPE were measured after 10 minutes of rest (Rest), warm-up (Pre), each 10-minute repetition, and at the end of the test (Post). CV4par was 1.33 ± 0.08 m·s. V[Combining Dot Above]O2, HR, [La], and RPE were similar between first 10-minute and Post time points in the 3 × 10-minute protocol. CV4par was equivalent to 92 ± 2% of the mean swimming speed of T400 (v400) for these swimmers. CV4par calculated through a single T400 (92%v400) showed excellent agreement (r = 0.30; 95% CI: -0.04 to 0.05 m·s, p = 0.39), low coefficient of variation (2%), and root mean square error of 0.02 ± 0.01 m·s when plotted against CV4par assessed through a 4-parameter model. These results generated the equation CV4par = 0.92 × v400. A single T400 can be used reliably to estimate the CV4par typically derived with 6 efforts in age-group swimmers.

  5. Critical Science Instrument Alignment of the James Webb Space Telescope (JWST) Integrated Science Instrument Module (ISIM)

    NASA Technical Reports Server (NTRS)

    Rohrbach, Scott O.; Kubalak, David A.; Gracey, Renee M.; Sabatke, Derek S.; Howard, Joseph M.; Telfer, Randal C.; Zielinski, Thomas P.

    2016-01-01

    This paper describes the critical instrument alignment terms associated with the six-degree of freedom alignment of each the Science Instrument (SI) in the James Webb Space Telescope (JWST), including focus, pupil shear, pupil clocking, and boresight. We present the test methods used during cryogenic-vacuum tests to directly measure the performance of each parameter, the requirements levied on each, and the impact of any violations of these requirements at the instrument and Observatory level.

  6. Testing backreaction effects with observational Hubble parameter data

    NASA Astrophysics Data System (ADS)

    Cao, Shu-Lei; Teng, Huan-Yu; Wan, Hao-Yi; Yu, Hao-Ran; Zhang, Tong-Jie

    2018-02-01

    The spatially averaged inhomogeneous Universe includes a kinematical backreaction term Q_{D} that is relate to the averaged spatial Ricci scalar _{D} in the framework of general relativity. Under the assumption that Q_{D} and < R > _{D} obey the scaling laws of the volume scale factor a_{D}, a direct coupling between them with a scaling index n is remarkable. In order to explore the generic properties of a backreaction model for explaining the accelerated expansion of the Universe, we exploit two metrics to describe the late time Universe. Since the standard FLRW metric cannot precisely describe the late time Universe on small scales, the template metric with an evolving curvature parameter κ _{D}(t) is employed. However, we doubt the validity of the prescription for κ _{D}, which motivates us apply observational Hubble parameter data (OHD) to constrain parameters in dust cosmology. First, for FLRW metric, by getting best-fit constraints of Ω^{D_0}_m = 0.25^{+0.03}_{-0.03}, n = 0.02^{+0.69}_{-0.66}, and H_{D_0} = 70.54^{+4.24}_{-3.97} km s^{-1 Mpc^{-1}}, the evolutions of parameters are explored. Second, in template metric context, by marginalizing over H_{D_0} as a prior of uniform distribution, we obtain the best-fit values of n=-1.22^{+0.68}_{-0.41} and Ωm^{D0}=0.12^{+0.04}_{-0.02}. Moreover, we utilize three different Gaussian priors of H_{D_0}, which result in different best-fits of n, but almost the same best-fit value of Ωm^{D0}˜ 0.12. Also, the absolute constraints without marginalization of parameter are obtained: n=-1.1^{+0.58}_{-0.50} and Ωm^{D0}=0.13± 0.03. With these constraints, the evolutions of the effective deceleration parameter q^{D} indicate that the backreaction can account for the accelerated expansion of the Universe without involving extra dark energy component in the scaling solution context. Nevertheless, the results also verify that the prescription of κ _{D} is insufficient and should be improved.

  7. Product Module Rig Test

    NASA Technical Reports Server (NTRS)

    Holdeman, James D. (Technical Monitor); Chiappetta, Louis, Jr.; Hautman, Donald J.; Ols, John T.; Padget, Frederick C., IV; Peschke, William O. T.; Shirley, John A.; Siskind, Kenneth S.

    2004-01-01

    The low emissions potential of a Rich-Quench-Lean (RQL) combustor for use in the High Speed Civil Transport (HSCT) application was evaluated as part of Work Breakdown Structure (WBS) 1.0.2.7 of the NASA Critical Propulsion Components (CPC) Program under Contract NAS3-27235. Combustion testing was conducted in cell 1E of the Jet Burner Test Stand at United Technologies Research Center. Specifically, a Rich-Quench-Lean combustor, utilizing reduced scale quench technology implemented in a quench vane concept in a product-like configuration (Product Module Rig), demonstrated the capability of achieving an emissions index of nitrogen oxides (NOx EI) of 8.5 gm/Kg fuel at the supersonic flight condition (relative to the program goal of 5 gm/Kg fuel). Developmental parametric testing of various quench vane configurations in the more fundamental flametube, Single Module Rig Configuration, demonstrated NOx EI as low as 5.2. All configurations in both the Product Module Rig configuration and the Single Module Rig configuration demonstrated exceptional efficiencies, greater than 99.95 percent, relative to the program goal of 99.9 percent efficiency at supersonic cruise conditions. Sensitivity of emissions to quench orifice design parameters were determined during the parametric quench vane test series in support of the design of the Product Module Rig configuration. For the rectangular quench orifices investigated, an aspect ratio (length/width) of approximately 2 was found to be near optimum. An optimum for orifice spacing was found to exist at approximately 0.167 inches, resulting in 24 orifices per side of a quench vane, for the 0.435 inch quench zone channel height investigated in the Single Module Rig. Smaller quench zone channel heights appeared to be beneficial in reducing emissions. Measurements were also obtained in the Single Module Rig configuration on the sensitivity of emissions to the critical combustor parameters of fuel/air ratio, pressure drop, and residence

  8. Batch Tests To Determine Activity Distribution and Kinetic Parameters for Acetate Utilization in Expanded-Bed Anaerobic Reactors

    PubMed Central

    Fox, Peter; Suidan, Makram T.

    1990-01-01

    Batch tests to measure maximum acetate utilization rates were used to determine the distribution of acetate utilizers in expanded-bed sand and expanded-bed granular activated carbon (GAC) reactors. The reactors were fed a mixture of acetate and 3-ethylphenol, and they contained the same predominant aceticlastic methanogen, Methanothrix sp. Batch tests were performed both on the entire reactor contents and with media removed from the reactors. Results indicated that activity was evenly distributed within the GAC reactors, whereas in the sand reactor a sludge blanket on top of the sand bed contained approximately 50% of the activity. The Monod half-velocity constant (Ks) for the acetate-utilizing methanogens in two expanded-bed GAC reactors was searched for by combining steady-state results with batch test data. All parameters necessary to develop a model with Monod kinetics were experimentally determined except for Ks. However, Ks was a function of the effluent 3-ethylphenol concentration, and batch test results demonstrated that maximum acetate utilization rates were not a function of the effluent 3-ethylphenol concentration. Addition of a competitive inhibition term into the Monod expression predicted the dependence of Ks on the effluent 3-ethylphenol concentration. A two-parameter search determined a Ks of 8.99 mg of acetate per liter and a Ki of 2.41 mg of 3-ethylphenol per liter. Model predictions were in agreement with experimental observations for all effluent 3-ethylphenol concentrations. Batch tests measured the activity for a specific substrate and determined the distribution of activity in the reactor. The use of steady-state data in conjunction with batch test results reduced the number of unknown kinetic parameters and thereby reduced the uncertainty in the results and the assumptions made. PMID:16348175

  9. Batch tests to determine activity distribution and kinetic parameters for acetate utilization in expanded-bed anaerobic reactors.

    PubMed

    Fox, P; Suidan, M T

    1990-04-01

    Batch tests to measure maximum acetate utilization rates were used to determine the distribution of acetate utilizers in expanded-bed sand and expanded-bed granular activated carbon (GAC) reactors. The reactors were fed a mixture of acetate and 3-ethylphenol, and they contained the same predominant aceticlastic methanogen, Methanothrix sp. Batch tests were performed both on the entire reactor contents and with media removed from the reactors. Results indicated that activity was evenly distributed within the GAC reactors, whereas in the sand reactor a sludge blanket on top of the sand bed contained approximately 50% of the activity. The Monod half-velocity constant (K(s)) for the acetate-utilizing methanogens in two expanded-bed GAC reactors was searched for by combining steady-state results with batch test data. All parameters necessary to develop a model with Monod kinetics were experimentally determined except for K(s). However, K(s) was a function of the effluent 3-ethylphenol concentration, and batch test results demonstrated that maximum acetate utilization rates were not a function of the effluent 3-ethylphenol concentration. Addition of a competitive inhibition term into the Monod expression predicted the dependence of K(s) on the effluent 3-ethylphenol concentration. A two-parameter search determined a K(s) of 8.99 mg of acetate per liter and a K(i) of 2.41 mg of 3-ethylphenol per liter. Model predictions were in agreement with experimental observations for all effluent 3-ethylphenol concentrations. Batch tests measured the activity for a specific substrate and determined the distribution of activity in the reactor. The use of steady-state data in conjunction with batch test results reduced the number of unknown kinetic parameters and thereby reduced the uncertainty in the results and the assumptions made.

  10. Impedance learning for robotic contact tasks using natural actor-critic algorithm.

    PubMed

    Kim, Byungchan; Park, Jooyoung; Park, Shinsuk; Kang, Sungchul

    2010-04-01

    Compared with their robotic counterparts, humans excel at various tasks by using their ability to adaptively modulate arm impedance parameters. This ability allows us to successfully perform contact tasks even in uncertain environments. This paper considers a learning strategy of motor skill for robotic contact tasks based on a human motor control theory and machine learning schemes. Our robot learning method employs impedance control based on the equilibrium point control theory and reinforcement learning to determine the impedance parameters for contact tasks. A recursive least-square filter-based episodic natural actor-critic algorithm is used to find the optimal impedance parameters. The effectiveness of the proposed method was tested through dynamic simulations of various contact tasks. The simulation results demonstrated that the proposed method optimizes the performance of the contact tasks in uncertain conditions of the environment.

  11. Utility of transthoracic echocardiography (TTE) in assessing fluid responsiveness in critically ill patients - a challenge for the bedside sonographer.

    PubMed

    Mielnicki, Wojciech; Dyla, Agnieszka; Zawada, Tomasz

    2016-12-05

    Transthoracic echocardiography (TTE) has become one of the most important diagnostic tools in the treatment of critically ill patients. It allows clinicians to recognise potentially reversible life-threatening situations and is also very effective in the monitoring of the fluid status of patients, slowly substituting invasive methods in the intensive care unit. Hemodynamic assessment is based on a few static and dynamic parameters. Dynamic parameters change during the respiratory cycle in mechanical ventilation and the level of this change directly corresponds to fluid responsiveness. Most of the parameters cannot be used in spontaneously breathing patients. For these patients the most important test is passive leg raising, which is a good substitute for fluid bolus. Although TTE is very useful in the critical care setting, we should not forget the important limitations, not only technical ones but also caused by the critical illness itself. Unfortunately, this method does not allow continuous monitoring and every change in the patient's condition requires repeated examination.

  12. Deducing Electronic Unit Internal Response During a Vibration Test Using a Lumped Parameter Modeling Approach

    NASA Technical Reports Server (NTRS)

    Van Dyke, Michael B.

    2014-01-01

    During random vibration testing of electronic boxes there is often a desire to know the dynamic response of certain internal printed wiring boards (PWBs) for the purpose of monitoring the response of sensitive hardware or for post-test forensic analysis in support of anomaly investigation. Due to restrictions on internally mounted accelerometers for most flight hardware there is usually no means to empirically observe the internal dynamics of the unit, so one must resort to crude and highly uncertain approximations. One common practice is to apply Miles Equation, which does not account for the coupled response of the board in the chassis, resulting in significant over- or under-prediction. This paper explores the application of simple multiple-degree-of-freedom lumped parameter modeling to predict the coupled random vibration response of the PWBs in their fundamental modes of vibration. A simple tool using this approach could be used during or following a random vibration test to interpret vibration test data from a single external chassis measurement to deduce internal board dynamics by means of a rapid correlation analysis. Such a tool might also be useful in early design stages as a supplemental analysis to a more detailed finite element analysis to quickly prototype and analyze the dynamics of various design iterations. After developing the theoretical basis, a lumped parameter modeling approach is applied to an electronic unit for which both external and internal test vibration response measurements are available for direct comparison. Reasonable correlation of the results demonstrates the potential viability of such an approach. Further development of the preliminary approach presented in this paper will involve correlation with detailed finite element models and additional relevant test data.

  13. [Clinical parameters for molecular testing of Maturity Onset Diabetes of the Young (MODY)].

    PubMed

    Datz, N; Nestoris, C; von Schütz, W; Danne, T; Driesel, A J; Maringa, M; Kordonouri, O

    2011-05-01

    Monogenic forms of diabetes are often diagnosed by chance, due to the variety of clinical presentation and limited experience of the diabetologists with this kind of diabetes. Aim of this study was to evaluate clinical parameters for an efficient screening. Clinical parameters were: negative diabetes-specific antibodies at onset of diabetes, positive family history of diabetes, and low to moderate insulin requirements after one year of diabetes treatment. Molecular testing was performed through sequencing of the programming regions of HNF-4alpha (MODY 1), glucokinase (MODY 2) and HNF-1alpha/TCF1 (MODY 3) and in one patient the HNF-1beta/TCF2 region (MODY 5). 39 of 292 patients treated with insulin were negative for GADA and IA2A, and 8 (20.5%) patients fulfilled both other criteria. Positive molecular results were found in five (63%) patients (two with MODY 2, two with MODY 3, one with MODY 5). At diabetes onset, the mean age of the 5 patients with MODY was 10.6 ± 5.3 yrs (range 2.6-15 yrs), HbA(1c) was 8.4 ± 3.1 % (6.5-13.9%), mean diabetes duration until diagnosis of MODY was 3.3 ± 3.6 yrs (0.8-9.6 yrs) with insulin requirements of 0.44 ± 0.17 U/kg/d (0.2-0.6 U/kg/d). Patients with MODY 3 were changed from insulin to repaglinide, those with MODY 2 were recommended discontinuing insulin treatment. In patients with negative diabetes-specific antibodies at onset of diabetes, with a positive family history, and low to moderate insulin needs a genetic screening for MODY is indicated. Watchful consideration of these clinical parameters may lead to an early genetic testing, and to an adequate treatment. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Critical assessment of precracked specimen configuration and experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate

    NASA Technical Reports Server (NTRS)

    Domack, M. S.

    1985-01-01

    A research program was conducted to critically assess the effects of precracked specimen configuration, stress intensity solutions, compliance relationships and other experimental test variables for stress corrosion testing of 7075-T6 aluminum alloy plate. Modified compact and double beam wedge-loaded specimens were tested and analyzed to determine the threshold stress intensity factor and stress corrosion crack growth rate. Stress intensity solutions and experimentally determined compliance relationships were developed and compared with other solutions available in the literature. Crack growth data suggests that more effective crack length measurement techniques are necessary to better characterize stress corrosion crack growth. Final load determined by specimen reloading and by compliance did not correlate well, and was considered a major source of interlaboratory variability. Test duration must be determined systematically, accounting for crack length measurement resolution, time for crack arrest, and experimental interferences. This work was conducted as part of a round robin program sponsored by ASTM committees G1.06 and E24.04 to develop a standard test method for stress corrosion testing using precracked specimens.

  15. A method for identifying EMI critical circuits during development of a large C3

    NASA Astrophysics Data System (ADS)

    Barr, Douglas H.

    The circuit analysis methods and process Boeing Aerospace used on a large, ground-based military command, control, and communications (C3) system are described. This analysis was designed to help identify electromagnetic interference (EMI) critical circuits. The methodology used the MIL-E-6051 equipment criticality categories as the basis for defining critical circuits, relational database technology to help sort through and account for all of the approximately 5000 system signal cables, and Macintosh Plus personal computers to predict critical circuits based on safety margin analysis. The EMI circuit analysis process systematically examined all system circuits to identify which ones were likely to be EMI critical. The process used two separate, sequential safety margin analyses to identify critical circuits (conservative safety margin analysis, and detailed safety margin analysis). These analyses used field-to-wire and wire-to-wire coupling models using both worst-case and detailed circuit parameters (physical and electrical) to predict circuit safety margins. This process identified the predicted critical circuits that could then be verified by test.

  16. Multi-Response Optimization of WEDM Process Parameters Using Taguchi Based Desirability Function Analysis

    NASA Astrophysics Data System (ADS)

    Majumder, Himadri; Maity, Kalipada

    2018-03-01

    Shape memory alloy has a unique capability to return to its original shape after physical deformation by applying heat or thermo-mechanical or magnetic load. In this experimental investigation, desirability function analysis (DFA), a multi-attribute decision making was utilized to find out the optimum input parameter setting during wire electrical discharge machining (WEDM) of Ni-Ti shape memory alloy. Four critical machining parameters, namely pulse on time (TON), pulse off time (TOFF), wire feed (WF) and wire tension (WT) were taken as machining inputs for the experiments to optimize three interconnected responses like cutting speed, kerf width, and surface roughness. Input parameter combination TON = 120 μs., TOFF = 55 μs., WF = 3 m/min. and WT = 8 kg-F were found to produce the optimum results. The optimum process parameters for each desired response were also attained using Taguchi’s signal-to-noise ratio. Confirmation test has been done to validate the optimum machining parameter combination which affirmed DFA was a competent approach to select optimum input parameters for the ideal response quality for WEDM of Ni-Ti shape memory alloy.

  17. Study on Material Parameters Identification of Brain Tissue Considering Uncertainty of Friction Coefficient

    NASA Astrophysics Data System (ADS)

    Guan, Fengjiao; Zhang, Guanjun; Liu, Jie; Wang, Shujing; Luo, Xu; Zhu, Feng

    2017-10-01

    Accurate material parameters are critical to construct the high biofidelity finite element (FE) models. However, it is hard to obtain the brain tissue parameters accurately because of the effects of irregular geometry and uncertain boundary conditions. Considering the complexity of material test and the uncertainty of friction coefficient, a computational inverse method for viscoelastic material parameters identification of brain tissue is presented based on the interval analysis method. Firstly, the intervals are used to quantify the friction coefficient in the boundary condition. And then the inverse problem of material parameters identification under uncertain friction coefficient is transformed into two types of deterministic inverse problem. Finally the intelligent optimization algorithm is used to solve the two types of deterministic inverse problems quickly and accurately, and the range of material parameters can be easily acquired with no need of a variety of samples. The efficiency and convergence of this method are demonstrated by the material parameters identification of thalamus. The proposed method provides a potential effective tool for building high biofidelity human finite element model in the study of traffic accident injury.

  18. Critical levels as applied to ozone for North American forests

    Treesearch

    Robert C. Musselman

    2006-01-01

    The United States and Canada have used concentration-based parameters for air quality standards for ozone effects on forests in North America. The European critical levels method for air quality standards uses an exposure-based parameter, a cumulative ozone concentration index with a threshold cutoff value. The critical levels method has not been used in North America...

  19. Multiaxial Fatigue Life Prediction Based on Nonlinear Continuum Damage Mechanics and Critical Plane Method

    NASA Astrophysics Data System (ADS)

    Wu, Z. R.; Li, X.; Fang, L.; Song, Y. D.

    2018-04-01

    A new multiaxial fatigue life prediction model has been proposed in this paper. The concepts of nonlinear continuum damage mechanics and critical plane criteria were incorporated in the proposed model. The shear strain-based damage control parameter was chosen to account for multiaxial fatigue damage under constant amplitude loading. Fatigue tests were conducted on nickel-based superalloy GH4169 tubular specimens at the temperature of 400 °C under proportional and nonproportional loading. The proposed method was checked against the multiaxial fatigue test data of GH4169. Most of prediction results are within a factor of two scatter band of the test results.

  20. The validation of science virtual test to assess 7th grade students’ critical thinking on matter and heat topic (SVT-MH)

    NASA Astrophysics Data System (ADS)

    Sya’bandari, Y.; Firman, H.; Rusyati, L.

    2018-05-01

    The method used in this research was descriptive research for profiling the validation of SVT-MH to measure students’ critical thinking on matter and heat topic in junior high school. The subject is junior high school students of 7th grade (13 years old) while science teacher and expert as the validators. The instruments that used as a tool to obtain the data are rubric expert judgment (content, media, education) and rubric of readability test. There are four steps to validate SVT-MH in 7th grade Junior High School. These steps are analysis of core competence and basic competence based on Curriculum 2013, expert judgment (content, media, education), readability test and trial test (limited and larger trial test). The instrument validation resulted 30 items that represent 8 elements and 21 sub-elements to measure students’ critical thinking based on Inch in matter and heat topic. The alpha Cronbach (α) is 0.642 which means that the instrument is sufficient to measure students’ critical thinking matter and heat topic.

  1. Evaluation of Visual Field Test Parameters after Artificial Tear Administration in Patients with Glaucoma and Dry Eye.

    PubMed

    Özyol, Pelin; Özyol, Erhan; Karalezli, Aylin

    2018-01-01

    To examine the effect of a single dose of artificial tear administration on automated visual field (VF) testing in patients with glaucoma and dry eye syndrome. A total of 35 patients with primary open-angle glaucoma experienced in VF testing with symptoms of dry eye were enrolled in this study. At the first visit, standard VF testing was performed. At the second and third visits with an interval of one week, while the left eyes served as control, one drop of artificial tear was administered to each patient's right eye, and then VF testing was performed again. The reliability parameters, VF indices, number of depressed points at probability levels of pattern deviation plots, and test times were compared between visits. No significant difference was observed in any VF testing parameters of control eyes (P>0.05). In artificial tear administered eyes, significant improvement was observed in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2) of pattern deviation plots (P˂0.05). The post-hoc test revealed that artificial tear administration elicited an improvement in test duration, mean deviation, and the number of depressed points at probability levels (P˂0.5%, P˂1%, P˂2%) of pattern deviation plots from first visit to second and third visits (P˂0.01, for all comparisons). The intraclass correlation coefficient for the three VF test indices was found to be between 0.735 and 0.85 (P<0.001, for all). A single dose of artificial tear administration immediately before VF testing seems to improve test results and decrease test time.

  2. Evaluation Parameters for Computer-Adaptive Testing

    ERIC Educational Resources Information Center

    Georgiadou, Elisabeth; Triantafillou, Evangelos; Economides, Anastasios A.

    2006-01-01

    With the proliferation of computers in test delivery today, adaptive testing has become quite popular, especially when examinees must be classified into two categories (passfail, master nonmaster). Several well-established organisations have provided standards and guidelines for the design and evaluation of educational and psychological testing.…

  3. Design and technology parameters influence on durability for heat exchangers tube to tubesheet joints

    NASA Astrophysics Data System (ADS)

    Ripeanu, R. G.

    2017-02-01

    The main failures of heat exchangers are: corrosion of tubes and jacket, tubes blockage and failures of tube to tubesheet joints also by corrosion. The most critical zone is tube to tubesheet joints. Depending on types of tube to tubesheet joints, in order to better respect conditions of tension and compression, this paper analyses the tubesheet holes shapes, smooth and with a grove, on corrosion behavior. In the case of welding tubes with tubesheet, welding parameters modify corrosion behavior. Were realized welded joints by three welding regimes and tested at corrosion in two media, tap water and industrial water. Were tested also samples made of smooth tubes, finned tubes and tubes coated with a passive product as applied by a heat exchanger manufacturer. For all samples, the roughness parameters were measured, before and after the corrosion tests. The obtained corrosion rates show that stress values and their distribution along the joint modify the corrosion behavior. The optimum welding parameters were established in order to increase the joint durability. The paper has shown that passive product used is not proper chosen and the technology of obtaining rolled thread pipes diminishes tubes’ durability by increasing the corrosion rate.

  4. Estimability of geodetic parameters from space VLBI observables

    NASA Technical Reports Server (NTRS)

    Adam, Jozsef

    1990-01-01

    The feasibility of space very long base interferometry (VLBI) observables for geodesy and geodynamics is investigated. A brief review of space VLBI systems from the point of view of potential geodetic application is given. A selected notational convention is used to jointly treat the VLBI observables of different types of baselines within a combined ground/space VLBI network. The basic equations of the space VLBI observables appropriate for convariance analysis are derived and included. The corresponding equations for the ground-to-ground baseline VLBI observables are also given for a comparison. The simplified expression of the mathematical models for both space VLBI observables (time delay and delay rate) include the ground station coordinates, the satellite orbital elements, the earth rotation parameters, the radio source coordinates, and clock parameters. The observation equations with these parameters were examined in order to determine which of them are separable or nonseparable. Singularity problems arising from coordinate system definition and critical configuration are studied. Linear dependencies between partials are analytically derived. The mathematical models for ground-space baseline VLBI observables were tested with simulation data in the frame of some numerical experiments. Singularity due to datum defect is confirmed.

  5. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment.

    PubMed

    Nornoo, Adwoa O; Jackson, Jonathan; Axtell, Samantha

    2017-03-25

    Objective. To determine whether there is a correlation between pharmacy students' scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman's rho correlation test was performed. Results. A very weak but significant positive correlation was found between students' grades on the assignment and their overall HSRT score (r=0.19, p <0.05), as well as deduction (a scale score of the HSRT; r=0.26, p <0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students.

  6. Investigating the Correlation Between Pharmacy Student Performance on the Health Science Reasoning Test and a Critical Thinking Assignment

    PubMed Central

    Jackson, Jonathan; Axtell, Samantha

    2017-01-01

    Objective. To determine whether there is a correlation between pharmacy students’ scores on the Health Science Reasoning Test (HSRT) and their grade on a package insert assignment designed to assess critical thinking. Methods. The HSRT was administered to first-year pharmacy students during a critical-thinking course in the spring semester. In the same semester, a required package insert assignment was completed in a pharmacokinetics course. To determine whether there was a relationship between HSRT scores and grades on the assignment, a Spearman’s rho correlation test was performed. Results. A very weak but significant positive correlation was found between students’ grades on the assignment and their overall HSRT score (r=0.19, p<0.05), as well as deduction (a scale score of the HSRT; r=0.26, p<0.01). Conclusion. Based on a very weak but significant correlation to HSRT scores, this study demonstrated the potential of a package insert assignment to be used as one of the components to measure critical-thinking skills in pharmacy students. PMID:28381884

  7. A Three-Parameter Model for Predicting Fatigue Life of Ductile Metals Under Constant Amplitude Multiaxial Loading

    NASA Astrophysics Data System (ADS)

    Liu, Jia; Li, Jing; Zhang, Zhong-ping

    2013-04-01

    In this article, a fatigue damage parameter is proposed to assess the multiaxial fatigue lives of ductile metals based on the critical plane concept: Fatigue crack initiation is controlled by the maximum shear strain, and the other important effect in the fatigue damage process is the normal strain and stress. This fatigue damage parameter introduces a stress-correlated factor, which describes the degree of the non-proportional cyclic hardening. Besides, a three-parameter multiaxial fatigue criterion is used to correlate the fatigue lifetime of metallic materials with the proposed damage parameter. Under the uniaxial loading, this three-parameter model reduces to the recently developed Zhang's model for predicting the uniaxial fatigue crack initiation life. The accuracy and reliability of this three-parameter model are checked against the experimental data found in literature through testing six different ductile metals under various strain paths with zero/non-zero mean stress.

  8. P-V criticality of conformal gravity holography in four dimensions

    NASA Astrophysics Data System (ADS)

    Pradhan, Parthapratim

    2018-02-01

    We examine the critical behavior, i.e. P-V criticality of conformal gravity (CG) in an extended phase space in which the cosmological constant should be interpreted as a thermodynamic pressure and the corresponding conjugate quantity as a thermodynamic volume. The main potential point of interest in CG is that there exists a nontrivial Rindler parameter (a) in the spacetime geometry. This geometric parameter has an important role to construct a model for gravity at large distances where the parameter “a” actually originates. We also investigate the effect of the said parameter on the black hole (BH) thermodynamic equation of state, critical constants, Reverse Isoperimetric Inequality, first law of thermodynamics, Hawking-Page phase transition and Gibbs free energy for this BH. We speculate that due to the presence of the said parameter, there has been a deformation in the shape of the isotherms in the P-V diagram in comparison with the charged-anti de Sitter (AdS) BH and the chargeless-AdS BH. Interestingly, we find that the critical ratio for this BH is ρc = Pcvc Tc = 3 2 32 ‑ 23, which is greater than the charged AdS BH and Schwarzschild-AdS BH, i.e. ρcCG : ρ cSch-AdS : ρ cRN-AdS = 0.67 : 0.50 : 0.37. The symbols are defined in the main work. Moreover, we observe that the critical ratio has a constant value and it is independent of the nontrivial Rindler parameter (a). Finally, we derive the reduced equation of state in terms of the reduced temperature, the reduced volume and the reduced pressure, respectively.

  9. Target parameter estimation

    NASA Technical Reports Server (NTRS)

    Hocking, W. K.

    1989-01-01

    The objective of any radar experiment is to determine as much as possible about the entities which scatter the radiation. This review discusses many of the various parameters which can be deduced in a radar experiment, and also critically examines the procedures used to deduce them. Methods for determining the mean wind velocity, the RMS fluctuating velocities, turbulence parameters, and the shapes of the scatterers are considered. Complications with these determinations are discussed. It is seen throughout that a detailed understanding of the shape and cause of the scatterers is important in order to make better determinations of these various quantities. Finally, some other parameters, which are less easily acquired, are considered. For example, it is noted that momentum fluxes due to buoyancy waves and turbulence can be determined, and on occasions radars can be used to determine stratospheric diffusion coefficients and even temperature profiles in the atmosphere.

  10. Correlations for Vapor Nucleating Critical Embryo Parameters

    NASA Astrophysics Data System (ADS)

    Magnusson, Lars-Erik; Koropchak, John A.; Anisimov, Michael P.; Poznjakovskiy, Valeriy M.; de la Mora, Juan Fernandez

    2003-12-01

    Condensation nucleation light scattering detection in principle works by converting the effluent of the chromatographic separation into an aerosol and then selectively evaporating the mobile phase, leaving less volatile analytes and nonvolatile impurities as dry aerosol particles. The dry particles produced are then exposed to an environment that is saturated with the vapors of an organic solvent (commonly n-butanol). The blend of aerosol particles and organic vapor is then cooled so that conditions of vapor supersaturation are achieved. In principle, the vapor then condenses onto the dry particles, growing each particle (ideally) from as small as a few nanometers in diameter into a droplet with a diameter up to about 10 μm. The grown droplets are then passed through a beam of light, and the light scattered by the droplets is detected and used as the detector response. This growth and detection step is generally carried out using commercial continuous-flow condensation nucleus counters. In the present research, the possibility of using other fluids than the commonly used n-butanol is investigated. The Kelvin equation and the Nucleation theorem [Anisimov et al. (1978)] are used to evaluate a range of fluids for efficacy of growing small particles by condensation nucleation. Using the available experimental data on vapor nucleation, the correlations of Kelvin diameters (the critical embryo sizes) and the bulk surface tension with dielectric constants of working liquids are found. A simple method for choosing the most efficient fluid, within a class of fluids, for growth of small particles is suggested.

  11. Lateral and longitudinal aerodynamic stability and control parameters of the basic vortex flap research aircraft as determined from flight test data

    NASA Technical Reports Server (NTRS)

    Suit, W. T.; Batterson, J. G.

    1986-01-01

    The aerodynamics of the basic F-106B were determined at selected points in the flight envelope. The test aircraft and flight procedures were presented. Aircraft instrumentation and the data system were discussed. The parameter extraction procedure was presented along with a discussion of the test flight results. The results were used to predict the aircraft motions for maneuvers that were not used to determine the vehicle aerodynamics. The control inputs used to maneuver the aircraft to get data for the determination of the aerodynamic parameters were discussed in the flight test procedures. The results from the current flight tests were compared with the results from wind tunnel test of the basic F-106B.

  12. Homegrown Tests Measure Core Critical-Reading Skills

    ERIC Educational Resources Information Center

    Olson, Lynn

    2007-01-01

    This article features FAST-R, or Formative Assessments of Student Thinking in Reading, a new assessment tool that measures critical-reading skills. FAST-R was developed by the the nonprofit Boston Plan for Excellence (BPE), a local education foundation, to provide teachers with information about what students are thinking when they try to find…

  13. Critical modeling parameters identified for 3D CFD modeling of rectangular final settling tanks for New York City wastewater treatment plants.

    PubMed

    Ramalingam, K; Xanthos, S; Gong, M; Fillos, J; Beckmann, K; Deur, A; McCorquodale, J A

    2012-01-01

    New York City Environmental Protection is in the process of incorporating biological nitrogen removal (BNR) in its wastewater treatment plants (WWTPs) which entails operating the aeration tanks with higher levels of mixed liquor suspended solids (MLSS) than a conventional activated sludge process. The objective of this paper is to discuss two of the important parameters introduced in the 3D CFD model that has been developed by the City College of New York (CCNY) group: (a) the development of the 'discrete particle' measurement technique to carry out the fractionation of the solids in the final settling tank (FST) which has critical implications in the prediction of the effluent quality; and (b) the modification of the floc aggregation (K(A)) and floc break-up (K(B)) coefficients that are found in Parker's flocculation equation (Parker et al. 1970, 1971) used in the CFD model. The dependence of these parameters on the predictions of the CFD model will be illustrated with simulation results on one of the FSTs at the 26th Ward WWTP in Brooklyn, NY.

  14. 30 CFR 7.45 - Critical characteristics

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.45 Critical characteristics The following critical characteristics shall be inspected or tested on each battery assembly to...

  15. 30 CFR 7.45 - Critical characteristics

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.45 Critical characteristics The following critical characteristics shall be inspected or tested on each battery assembly to...

  16. Local and nonlocal order parameters in the Kitaev chain

    NASA Astrophysics Data System (ADS)

    Chitov, Gennady Y.

    2018-02-01

    We have calculated order parameters for the phases of the Kitaev chain with interaction and dimerization at a special symmetric point applying the Jordan-Wigner and other duality transformations. We use string order parameters (SOPs) defined via the correlation functions of the Majorana string operators. The SOPs are mapped onto the local order parameters of some dual Hamiltonians and easily calculated. We have shown that the phase diagram of the interacting dimerized chain comprises the phases with the conventional local order as well as the phases with nonlocal SOPs. From the results for the critical indices, we infer the two-dimensional Ising universality class of criticality at the particular symmetry point where the model is exactly solvable.

  17. Hot-crack test for aluminium alloys welds using TIG process

    NASA Astrophysics Data System (ADS)

    Niel, A.; Deschaux-Beaume, F.; Bordreuil, C.; Fras, G.

    2010-06-01

    Hot cracking is a critical defect frequently observed during welding of aluminium alloys. In order to better understand the interaction between cracking phenomenon, process parameters, mechanical factors and microstructures resulting from solidification after welding, an original hot-cracking test during welding is developed. According to in-situ observations and post mortem analyses, hot cracking mechanisms are investigated, taking into account the interaction between microstructural parameters, depending on the thermal cycles, and mechanical parameters, depending on geometry and clamping conditions of the samples and on the thermal field on the sample. Finally, a process map indicating the limit between cracking and non-cracking zones according to welding parameters is presented.

  18. Analysis Test of Understanding of Vectors with the Three-Parameter Logistic Model of Item Response Theory and Item Response Curves Technique

    ERIC Educational Resources Information Center

    Rakkapao, Suttida; Prasitpong, Singha; Arayathanitkul, Kwan

    2016-01-01

    This study investigated the multiple-choice test of understanding of vectors (TUV), by applying item response theory (IRT). The difficulty, discriminatory, and guessing parameters of the TUV items were fit with the three-parameter logistic model of IRT, using the parscale program. The TUV ability is an ability parameter, here estimated assuming…

  19. Cell death, perfusion and electrical parameters are critical in models of hepatic radiofrequency ablation

    PubMed Central

    Hall, Sheldon K.; Ooi, Ean H.; Payne, Stephen J.

    2015-01-01

    Abstract Purpose: A sensitivity analysis has been performed on a mathematical model of radiofrequency ablation (RFA) in the liver. The purpose of this is to identify the most important parameters in the model, defined as those that produce the largest changes in the prediction. This is important in understanding the role of uncertainty and when comparing the model predictions to experimental data. Materials and methods: The Morris method was chosen to perform the sensitivity analysis because it is ideal for models with many parameters or that take a significant length of time to obtain solutions. A comprehensive literature review was performed to obtain ranges over which the model parameters are expected to vary, crucial input information. Results: The most important parameters in predicting the ablation zone size in our model of RFA are those representing the blood perfusion, electrical conductivity and the cell death model. The size of the 50 °C isotherm is sensitive to the electrical properties of tissue while the heat source is active, and to the thermal parameters during cooling. Conclusions: The parameter ranges chosen for the sensitivity analysis are believed to represent all that is currently known about their values in combination. The Morris method is able to compute global parameter sensitivities taking into account the interaction of all parameters, something that has not been done before. Research is needed to better understand the uncertainties in the cell death, electrical conductivity and perfusion models, but the other parameters are only of second order, providing a significant simplification. PMID:26000972

  20. Scaled equation of state parameters for gases in the critical region

    NASA Technical Reports Server (NTRS)

    Sengers, J. M. H. L.; Greer, W. L.; Sengers, J. V.

    1976-01-01

    In the light of recent theoretical developments, the paper presents an accurate characterization of anomalous thermodynamic behavior of xenon, helium 4, helium 3, carbon dioxide, steam and oxygen in the critical region. This behavior is associated with long range fluctuations in the system and the physical properties depend primarily on a single variable, namely, the correlation length. A description of the thermodynamic behavior of fluids in terms of scaling laws is formulated, and the two successfully used scaled equations of state (NBS equation and Linear Model parametric equation) are compared. Methods for fitting both equations to experimental equation of state data are developed and formulated, and the optimum fit for each of the two scaled equations of the above gases are presented and the results are compared. By extending the experimental data for the above one-component fluids to partially miscible binary liquids, superfluid liquid helium, ferromagnets and solids exhibiting order-disorder transitions, the principle of universality is concluded. Finally by using this principle, the critical regions for nine additional fluids are described.

  1. ENDF/B-VII.0 Data Testing Using 1,172 Critical Assemblies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plechaty, E F; Cullen, D E

    2007-10-01

    In order to test the ENDF/B-VII.0 neutron data library [1], 1,172 critical assemblies from [2] have been calculated using the Monte Carlo transport code TART [3]. TART's 'best' physics was used for all of these calculations; this included continuous energy cross sections, delayed neutrons in their spectrum that is slower than prompt neutrons, unresolved resonance region self-shielding, the thermal scattering (free atom for all materials plus thermal scattering law data S({alpha},{beta}) when available). In this first pass through the assemblies the objective was to 'quickly' test the validity of the ENDF/B-VII.0 data [1], the assembly models as defined in [2]more » and coded for use with TART, and TART's physics treatment [3] of these assemblies. With TART we have the option of running criticality problems until K-eff has been calculated to an acceptable input accuracy. In order to 'quickly' calculate all of these assemblies K-eff was calculated in each case to +/- 0.002. For these calculations the assemblies were divided into ten types based on fuel (mixed, Pu239, U233, U235) and median fission energy (Fast, Midi, Slow). A table is provided that shows a summary of these results. This is followed be details for every assembly, and statistical information about the distribution of K-eff for each type of assembly. After a review of these results to eliminate any obvious errors in ENDF/B data, assembly models, or TART physics, all assemblies will be run again to a higher precision. Only after this second run is finished will we have highly precise results. Until then the results presently here should only be interpreted as approximate values of K-eff with a standard deviation of +/- 0.002; for such a large number of assemblies we expected the results to be approximately normal, with a spread out to several times the standard deviation; see the calculated statistical distributions and their comparisons to a normal distribution.« less

  2. Effect of Deformation Parameters on Microstructure and Properties During DIFT of X70HD Pipeline Steel

    NASA Astrophysics Data System (ADS)

    Wang, Jian; Zhu, Wei; Xiao, Hong; Zhang, Liang-liang; Qin, Hao; Yu, Yue

    2018-02-01

    Grain refinement is a critical approach to improve the strength of materials without damaging the toughness. The grains of deformation-induced ferrite are considerably smaller than those of proeutectoid ferrite. Grain refinement is crucial to the application of deformation-induced ferrite. The composition of ferrite and bainite or martensite is important in controlling the performance of X70HD pipeline steel, and cooling significantly influences the control of their ratio and grain size. By analyzing the static and dynamic phase-transition points using Gleeble-3800 thermal simulator, thermal simulations were performed through two-stage deformations in the austenite zone. Ferrite transformation rules were studied with thermal simulation tests under different deformation and cooling parameters based on the actual production of cumulative deformation. The influence of deformation parameters on the microstructure transformation was analyzed. Numerous fine-grain deformation-induced ferrites were obtained by regulating various parameters, including deformation temperature, strain rate, cooling rate, final cooling temperature and other parameters. Results of metallographic observation and microtensile testing revealed that the selection of appropriate parameters can refine the grains and improve the performance of the X70HD pipeline steel.

  3. Exact test-based approach for equivalence test with parameter margin.

    PubMed

    Cassie Dong, Xiaoyu; Bian, Yuanyuan; Tsong, Yi; Wang, Tianhua

    2017-01-01

    The equivalence test has a wide range of applications in pharmaceutical statistics which we need to test for the similarity between two groups. In recent years, the equivalence test has been used in assessing the analytical similarity between a proposed biosimilar product and a reference product. More specifically, the mean values of the two products for a given quality attribute are compared against an equivalence margin in the form of ±f × σ R , where ± f × σ R is a function of the reference variability. In practice, this margin is unknown and is estimated from the sample as ±f × S R . If we use this estimated margin with the classic t-test statistic on the equivalence test for the means, both Type I and Type II error rates may inflate. To resolve this issue, we develop an exact-based test method and compare this method with other proposed methods, such as the Wald test, the constrained Wald test, and the Generalized Pivotal Quantity (GPQ) in terms of Type I error rate and power. Application of those methods on data analysis is also provided in this paper. This work focuses on the development and discussion of the general statistical methodology and is not limited to the application of analytical similarity.

  4. Estimation of Handling Qualities Parameters of the Tu-144 Supersonic Transport Aircraft from Flight Test Data

    NASA Technical Reports Server (NTRS)

    Curry, Timothy J.; Batterson, James G. (Technical Monitor)

    2000-01-01

    Low order equivalent system (LOES) models for the Tu-144 supersonic transport aircraft were identified from flight test data. The mathematical models were given in terms of transfer functions with a time delay by the military standard MIL-STD-1797A, "Flying Qualities of Piloted Aircraft," and the handling qualities were predicted from the estimated transfer function coefficients. The coefficients and the time delay in the transfer functions were estimated using a nonlinear equation error formulation in the frequency domain. Flight test data from pitch, roll, and yaw frequency sweeps at various flight conditions were used for parameter estimation. Flight test results are presented in terms of the estimated parameter values, their standard errors, and output fits in the time domain. Data from doublet maneuvers at the same flight conditions were used to assess the predictive capabilities of the identified models. The identified transfer function models fit the measured data well and demonstrated good prediction capabilities. The Tu-144 was predicted to be between level 2 and 3 for all longitudinal maneuvers and level I for all lateral maneuvers. High estimates of the equivalent time delay in the transfer function model caused the poor longitudinal rating.

  5. Experimental criticality specifications. An annotated bibliography through 1977

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paxton, H.C.

    1978-05-01

    The compilation of approximately 300 references gives sources of experimental criticality parameters of systems containing /sup 235/U, /sup 233/U, and /sup 239/Pu. The intent is to cover basic data for criticality safety applications. The references are arranged by subject.

  6. Critical behavior near the ferromagnetic phase transition in double perovskite Nd2NiMnO6

    NASA Astrophysics Data System (ADS)

    Ali, Anzar; Sharma, G.; Singh, Yogesh

    2018-05-01

    The knowledge of critical exponents plays a crucial role in trying to understand the interaction mechanism near a phase transition. In this report, we present a detailed study of the critical behaviour near the ferromagnetic (FM) transition (TC ˜ 193 K) in Nd2NiMnO6 using the temperature and magnetic field dependent isothermal magnetisation measurements. We used various analysis methods such as Arrott plot, modified Arrott plot, and Kouvel-Fisher plot to estimate the critical parameters. The magnetic critical parameters β = 0.49±0.02, γ = 1.05±0.04 and critical isothermal parameter δ = 3.05±0.02 are in excellent agreement with Widom scaling. The critical parameters analysis emphasizes that mean field interaction is the mechanism driving the FM transition in Nd2NiMnO6.

  7. The role of student’s critical asking question in developing student’s critical thinking skills

    NASA Astrophysics Data System (ADS)

    Santoso, T.; Yuanita, L.; Erman, E.

    2018-01-01

    Questioning means thinking, and thinking is manifested in the form of questions. Research that studies the relationship between questioning and students’ critical thinking skills is little, if any. The aim of this study is to examine how student’s questions skill correlates to student’s critical thinking skills in learning of chemistry. The research design used was one group pretest-posttest design. The participants involved were 94 students, all of whom attended their last semesters, Chemistry Education of Tadulako University. A pre-test was administered to check participants’ ability to ask critical questions and critical thinking skills in learning chemistry. Then, the students were taught by using questioning technique. After accomplishing the lesson, a post-test was given to evaluate their progress. Obtained data were analyzed by using Pair-Samples T.Test and correlation methods. The result shows that the level of the questions plays an important role in critical thinking skills is the question levels of predictive, analysis, evaluation and inference.

  8. Quantum Critical Higgs

    NASA Astrophysics Data System (ADS)

    Bellazzini, Brando; Csáki, Csaba; Hubisz, Jay; Lee, Seung J.; Serra, Javi; Terning, John

    2016-10-01

    The appearance of the light Higgs boson at the LHC is difficult to explain, particularly in light of naturalness arguments in quantum field theory. However, light scalars can appear in condensed matter systems when parameters (like the amount of doping) are tuned to a critical point. At zero temperature these quantum critical points are directly analogous to the finely tuned standard model. In this paper, we explore a class of models with a Higgs near a quantum critical point that exhibits non-mean-field behavior. We discuss the parametrization of the effects of a Higgs emerging from such a critical point in terms of form factors, and present two simple realistic scenarios based on either generalized free fields or a 5D dual in anti-de Sitter space. For both of these models, we consider the processes g g →Z Z and g g →h h , which can be used to gain information about the Higgs scaling dimension and IR transition scale from the experimental data.

  9. Uncertainty analysis on simple mass balance model to calculate critical loads for soil acidity.

    PubMed

    Li, Harbin; McNulty, Steven G

    2007-10-01

    Simple mass balance equations (SMBE) of critical acid loads (CAL) in forest soil were developed to assess potential risks of air pollutants to ecosystems. However, to apply SMBE reliably at large scales, SMBE must be tested for adequacy and uncertainty. Our goal was to provide a detailed analysis of uncertainty in SMBE so that sound strategies for scaling up CAL estimates to the national scale could be developed. Specifically, we wanted to quantify CAL uncertainty under natural variability in 17 model parameters, and determine their relative contributions in predicting CAL. Results indicated that uncertainty in CAL came primarily from components of base cation weathering (BC(w); 49%) and acid neutralizing capacity (46%), whereas the most critical parameters were BC(w) base rate (62%), soil depth (20%), and soil temperature (11%). Thus, improvements in estimates of these factors are crucial to reducing uncertainty and successfully scaling up SMBE for national assessments of CAL.

  10. TESTING OF TMR SAND MANTIS FINAL REPORT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krementz, D; William Daugherty, W

    2007-06-12

    Screening tests of Sand Mantis candidate materials selected for erosion resistance have been completed. The results of this testing identified that over a relatively short period of operation (<1 hour), measurable erosion will occur in each of the candidate zoom tube materials given equal operating exposure. Additionally, this testing has shown that erosion of the rubber discharge hose directly downstream of the vehicle could be expected to limit the service life of the discharge hose. On the basis of these test results, SRNL recommends the following; {lg_bullet} redesign of critical system components (e.g., zoom tube, discharge hose) should be conductedmore » to improve system characteristics relative to erosion and capitalize on the results of this testing, {lg_bullet} continued efforts to deploy the Sand Mantis should include testing to better define and optimize operating parameters, and gain an understanding of system dynamics, {lg_bullet} discontinue wear testing with the selected materials pending redesign of critical system components (1st recommendation) and inclusion of other candidate materials. The final selection of additional candidate materials should be made following design changes, but might include a Stellite alloy or zirconia.« less

  11. 40 CFR 86.094-22 - Approval of application for certification; test fleet selections; determinations of parameters...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Audit and Production Compliance Audit testing, the adequacy of the limits, stops, seals, or other means... (Selective Enforcement Audit and Production Compliance Audit) only the actual settings to which the parameter... Selective Enforcement Audit, adequacy of limits, and physically adjustable ranges. 86.094-22 Section 86.094...

  12. Criticality features in ULF magnetic fields prior to the 2011 Tohoku earthquake

    PubMed Central

    HAYAKAWA, Masashi; SCHEKOTOV, Alexander; POTIRAKIS, Stelios; EFTAXIAS, Kostas

    2015-01-01

    The criticality of ULF (Ultra-low-frequency) magnetic variations is investigated for the 2011 March 11 Tohoku earthquake (EQ) by natural time analysis. For this attempt, some ULF parameters were considered: (1) Fh (horizontal magnetic field), (2) Fz (vertical magnetic field), and (3) Dh (inverse of horizontal magnetic field). The first two parameters refer to the ULF radiation, while the last parameter refers to another ULF effect of ionospheric signature. Nighttime (L.T. = 3 am ± 2 hours) data at Kakioka (KAK) were used, and the power of each quantity at a particular frequency band of 0.03–0.05 Hz was averaged for nighttime hours. The analysis results indicate that Fh fulfilled all criticality conditions on March 3–5, 2011, and that the additional parameter, Dh reached also a criticality on March 6 or 7. In conclusion, criticality has reached in the pre-EQ fracture region a few days to one week before the main shock of the Tohoku EQ. PMID:25743063

  13. Criticality of Low-Energy Protons in Single-Event Effects Testing of Highly-Scaled Technologies

    NASA Technical Reports Server (NTRS)

    Pellish, Jonathan A.; Marshall, Paul W.; Rodbell, Kenneth P.; Gordon, Michael S.; LaBel, Kenneth A.; Schwank, James R.; Dodds, Nathaniel A.; Castaneda, Carlos M.; Berg, Melanie D.; Kim, Hak S.; hide

    2014-01-01

    We report low-energy proton and low-energy alpha particle single-event effects (SEE) data on a 32 nm silicon-on-insulator (SOI) complementary metal oxide semiconductor (CMOS) latches and static random access memory (SRAM) that demonstrates the criticality of using low-energy protons for SEE testing of highly-scaled technologies. Low-energy protons produced a significantly higher fraction of multi-bit upsets relative to single-bit upsets when compared to similar alpha particle data. This difference highlights the importance of performing hardness assurance testing with protons that include energy distribution components below 2 megaelectron-volt. The importance of low-energy protons to system-level single-event performance is based on the technology under investigation as well as the target radiation environment.

  14. Ischemic preconditioning enhances critical power during a 3 minute all-out cycling test.

    PubMed

    Griffin, Patrick J; Ferguson, Richard A; Gissane, Conor; Bailey, Stephen J; Patterson, Stephen D

    2018-05-01

    This study tested the hypothesis that ischemic preconditioning (IPC) would increase critical power (CP) during a 3 minute all-out cycling test. Twelve males completed two 3 minute all-out cycling tests, in a crossover design, separated by 7 days. These tests were preceded by IPC (4 x 5 minute intervals at 220 mmHg bilateral leg occlusion) or SHAM treatment (4 x 5 minute intervals at 20 mmHg bilateral leg occlusion). CP was calculated as the mean power output during the final 30 s of the 3 minute test with W' taken as the total work done above CP. Muscle oxygenation was measured throughout the exercise period. There was a 15.3 ± 0.3% decrease in muscle oxygenation (TSI; [Tissue saturation index]) during the IPC stimulus, relative to SHAM. CP was significantly increased (241 ± 65 W vs. 234 ± 67 W), whereas W' (18.4 ± 3.8 vs 17.9 ± 3.7 kJ) and total work done (TWD) were not different (61.1 ± 12.7 vs 60.8 ± 12.7 kJ), between the IPC and SHAM trials. IPC enhanced CP during a 3 minute all-out cycling test without impacting W' or TWD. The improved CP after IPC might contribute towards the effect of IPC on endurance performance.

  15. A Comparison of the One-and Three-Parameter Logistic Models on Measures of Test Efficiency.

    ERIC Educational Resources Information Center

    Benson, Jeri

    Two methods of item selection were used to select sets of 40 items from a 50-item verbal analogies test, and the resulting item sets were compared for relative efficiency. The BICAL program was used to select the 40 items having the best mean square fit to the one parameter logistic (Rasch) model. The LOGIST program was used to select the 40 items…

  16. Determination of JWL Parameters for Non-Ideal Explosive

    NASA Astrophysics Data System (ADS)

    Hamashima, H.; Kato, Y.; Itoh, S.

    2004-07-01

    JWL equation of state is widely used in numerical simulation of detonation phenomena. JWL parameters are determined by cylinder test. Detonation characteristics of non-ideal explosive depend strongly on confinement, and JWL parameters determined by cylinder test do not represent the state of detonation products in many applications. We developed a method to determine JWL parameters from the underwater explosion test. JWL parameters were determined through a method of characteristics applied to the configuration of the underwater shock waves of cylindrical explosives. The numerical results obtained using JWL parameters determined by the underwater explosion test and those obtained using JWL parameters determined by cylinder test were compared with experimental results for typical non-ideal explosive; emulsion explosive. Good agreement was confirmed between the results obtained using JWL parameters determined by the underwater explosion test and experimental results.

  17. Influence of structural parameters on the tendency of VVER-1000 reactor pressure vessel steel to temper embrittlement

    NASA Astrophysics Data System (ADS)

    Gurovich, B.; Kuleshova, E.; Zabusov, O.; Fedotova, S.; Frolov, A.; Saltykov, M.; Maltsev, D.

    2013-04-01

    In this paper the influence of structural parameters on the tendency of steels to reversible temper embrittlement was studied for assessment of performance properties of reactor pressure vessel steels with extended service life. It is shown that the growth of prior austenite grain size leads to an increase of the critical embrittlement temperature in the initial state. An embrittlement heat treatment at the temperature of maximum manifestation of temper embrittlement (480 °C) shifts critical embrittlement temperature to higher values due to the increase of the phosphorus concentration on grain boundaries. There is a correlation between phosphorus concentration on boundaries of primary austenite grains and the share of brittle intergranular fracture (that, in turn, depends on impact test temperature) in the fracture surfaces of the tested Charpy specimens.

  18. Critical analysis of industrial electron accelerators

    NASA Astrophysics Data System (ADS)

    Korenev, S.

    2004-09-01

    The critical analysis of electron linacs for industrial applications (degradation of PTFE, curing of composites, modification of materials, sterlization and others) is considered in this report. Main physical requirements for industrial electron accelerators consist in the variations of beam parameters, such as kinetic energy and beam power. Questions for regulation of these beam parameters are considered. The level of absorbed dose in the irradiated product and throughput determines the main parameters of electron accelerator. The type of ideal electron linac for industrial applications is discussed.

  19. 16 CFR 1211.5 - General testing parameters.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... § 1211.4(c) for compliance with the Standard for Safety for Tests for Safety-Related Controls Employing... vibration level of 5g is to be used for the Vibration Test. (6) When a Computational Investigation is... tested. (8) The Endurance test is to be conducted concurrently with the Operational test. The control...

  20. 16 CFR 1211.5 - General testing parameters.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... § 1211.4(c) for compliance with the Standard for Safety for Tests for Safety-Related Controls Employing... vibration level of 5g is to be used for the Vibration Test. (6) When a Computational Investigation is... tested. (8) The Endurance test is to be conducted concurrently with the Operational test. The control...

  1. 16 CFR 1211.5 - General testing parameters.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... § 1211.4(c) for compliance with the Standard for Safety for Tests for Safety-Related Controls Employing... vibration level of 5g is to be used for the Vibration Test. (6) When a Computational Investigation is... tested. (8) The Endurance test is to be conducted concurrently with the Operational test. The control...

  2. Citizen Science: The Small World Initiative Improved Lecture Grades and California Critical Thinking Skills Test Scores of Nonscience Major Students at Florida Atlantic University.

    PubMed

    Caruso, Joseph P; Israel, Natalie; Rowland, Kimberly; Lovelace, Matthew J; Saunders, Mary Jane

    2016-03-01

    Course-based undergraduate research is known to improve science, technology, engineering, and mathematics student achievement. We tested "The Small World Initiative, a Citizen-Science Project to Crowdsource Novel Antibiotic Discovery" to see if it also improved student performance and the critical thinking of non-science majors in Introductory Biology at Florida Atlantic University (a large, public, minority-dominant institution) in academic year 2014-15. California Critical Thinking Skills Test pre- and posttests were offered to both Small World Initiative (SWI) and control lab students for formative amounts of extra credit. SWI lab students earned significantly higher lecture grades than control lab students, had significantly fewer lecture grades of D+ or lower, and had significantly higher critical thinking posttest total scores than control students. Lastly, more SWI students were engaged while taking critical thinking tests. These results support the hypothesis that utilizing independent course-based undergraduate science research improves student achievement even in nonscience students.

  3. New evaluation parameter for wearable thermoelectric generators

    NASA Astrophysics Data System (ADS)

    Wijethunge, Dimuthu; Kim, Woochul

    2018-04-01

    Wearable devices constitute a key application area for thermoelectric devices. However, owing to new constraints in wearable applications, a few conventional device optimization techniques are not appropriate and material evaluation parameters, such as figure of merit (zT) and power factor (PF), tend to be inadequate. We illustrated the incompleteness of zT and PF by performing simulations and considering different thermoelectric materials. The results indicate a weak correlation between device performance and zT and PF. In this study, we propose a new evaluation parameter, zTwearable, which is better suited for wearable applications compared to conventional zT. Owing to size restrictions, gap filler based device optimization is extremely critical in wearable devices. With respect to the occasions in which gap fillers are used, expressions for power, effective thermal conductivity (keff), and optimum load electrical ratio (mopt) are derived. According to the new parameters, the thermal conductivity of the material has become much more critical now. The proposed new evaluation parameter, namely, zTwearable, is extremely useful in the selection of an appropriate thermoelectric material among various candidates prior to the commencement of the actual design process.

  4. Development of base pressure similarity parameters for application to space shuttle launch vehicle power-on aerodynamic testing

    NASA Technical Reports Server (NTRS)

    Sulyma, P. R.; Penny, M. M.

    1978-01-01

    A base pressure data correlation study was conducted to define exhaust plume similarity parameters for use in Space Shuttle power-on launch vehicle aerodynamic test programs. Data correlations were performed for single bodies having, respectively, single and triple nozzle configurations and for a triple body configuration with single nozzles on each of the outside bodies. Base pressure similarity parameters were found to differ for the single nozzle and triple nozzle configurations. However, the correlation parameter for each was found to be a strong function of the nozzle exit momentum. Results of the data base evaluation are presented indicating an assessment of all data points. Analytical/experimental data comparisons were made for nozzle calibrations and correction factors derived, where indicated for use in nozzle exit plane data calculations.

  5. Does Critical Illness Change Levofloxacin Pharmacokinetics?

    PubMed

    Roberts, Jason A; Cotta, Menino Osbert; Cojutti, Piergiorgio; Lugano, Manuela; Della Rocca, Giorgio; Pea, Federico

    2015-12-14

    Levofloxacin is commonly used in critically ill patients for which existing data suggest nonstandard dosing regimens should be used. The objective of this study was to compare the population pharmacokinetics of levofloxacin in critically ill and in non-critically ill patients. Adult patients with a clinical indication for levofloxacin were eligible for participation in this prospective pharmacokinetic study. Patients were given 500 mg or 750 mg daily by intravenous administration with up to 11 blood samples taken on day 1 or 2 of therapy. Plasma samples were analyzed and population pharmacokinetic analysis was undertaken using Pmetrics. Thirty-five patients (18 critically ill) were included. The mean (standard deviation [SD]) age, weight, and Cockcroft-Gault creatinine clearance for the critically ill and for the non-critically ill patients were 60.3 (16.4) and 72.0 (11.6) years, 78.5 (14.8) and 70.9 (15.8) kg, and 71.9 (65.8) and 68.2 (30.1) ml/min, respectively. A two-compartment linear model best described the data. Increasing creatinine clearance was the only covariate associated with increasing drug clearance. The presence of critical illness did not significantly affect any pharmacokinetic parameter. The mean (SD) parameter estimates were as follows: clearance, 8.66 (3.85) liters/h; volume of the central compartment (Vc), 41.5 (24.5) liters; intercompartmental clearance constants from central to peripheral, 2.58 (3.51) liters/h; and peripheral to central compartments, 0.90 (0.58) liters/h. Monte Carlo dosing simulations demonstrated that achievement of therapeutic exposures was dependent on renal function, pathogen, and MIC. Critical illness appears to have no independent effect on levofloxacin pharmacokinetics that cannot be explained by altered renal function. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  6. Does Critical Illness Change Levofloxacin Pharmacokinetics?

    PubMed Central

    Cotta, Menino Osbert; Cojutti, Piergiorgio; Lugano, Manuela; Rocca, Giorgio Della; Pea, Federico

    2015-01-01

    Levofloxacin is commonly used in critically ill patients for which existing data suggest nonstandard dosing regimens should be used. The objective of this study was to compare the population pharmacokinetics of levofloxacin in critically ill and in non-critically ill patients. Adult patients with a clinical indication for levofloxacin were eligible for participation in this prospective pharmacokinetic study. Patients were given 500 mg or 750 mg daily by intravenous administration with up to 11 blood samples taken on day 1 or 2 of therapy. Plasma samples were analyzed and population pharmacokinetic analysis was undertaken using Pmetrics. Thirty-five patients (18 critically ill) were included. The mean (standard deviation [SD]) age, weight, and Cockcroft-Gault creatinine clearance for the critically ill and for the non-critically ill patients were 60.3 (16.4) and 72.0 (11.6) years, 78.5 (14.8) and 70.9 (15.8) kg, and 71.9 (65.8) and 68.2 (30.1) ml/min, respectively. A two-compartment linear model best described the data. Increasing creatinine clearance was the only covariate associated with increasing drug clearance. The presence of critical illness did not significantly affect any pharmacokinetic parameter. The mean (SD) parameter estimates were as follows: clearance, 8.66 (3.85) liters/h; volume of the central compartment (Vc), 41.5 (24.5) liters; intercompartmental clearance constants from central to peripheral, 2.58 (3.51) liters/h; and peripheral to central compartments, 0.90 (0.58) liters/h. Monte Carlo dosing simulations demonstrated that achievement of therapeutic exposures was dependent on renal function, pathogen, and MIC. Critical illness appears to have no independent effect on levofloxacin pharmacokinetics that cannot be explained by altered renal function. PMID:26666946

  7. Critical attributes of transdermal drug delivery system (TDDS)--a generic product development review.

    PubMed

    Ruby, P K; Pathak, Shriram M; Aggarwal, Deepika

    2014-11-01

    Bioequivalence testing of transdermal drug delivery systems (TDDS) has always been a subject of high concern for generic companies due to the formulation complexity and the fact that they are subtle to even minor manufacturing differences and hence should be clearly qualified in terms of quality, safety and efficacy. In recent times bioequivalence testing of transdermal patches has gained a global attention and many regulatory authorities worldwide have issued recommendations to set specific framework for demonstrating equivalence between two products. These current regulatory procedures demand a complete characterization of the generic formulation in terms of its physicochemical sameness, pharmacokinetics disposition, residual content and/or skin irritation/sensitization testing with respect to the reference formulation. This paper intends to highlight critical in vitro tests in assessing the therapeutic equivalence of products and also outlines their valuable applications in generic product success. Understanding these critical in vitro parameters can probably help to decode the complex bioequivalence outcomes, directing the generic companies to optimize the formulation design in reduced time intervals. It is difficult to summarize a common platform which covers all possible transdermal products; hence few case studies based on this approach has been presented in this review.

  8. Optimal critic learning for robot control in time-varying environments.

    PubMed

    Wang, Chen; Li, Yanan; Ge, Shuzhi Sam; Lee, Tong Heng

    2015-10-01

    In this paper, optimal critic learning is developed for robot control in a time-varying environment. The unknown environment is described as a linear system with time-varying parameters, and impedance control is employed for the interaction control. Desired impedance parameters are obtained in the sense of an optimal realization of the composite of trajectory tracking and force regulation. Q -function-based critic learning is developed to determine the optimal impedance parameters without the knowledge of the system dynamics. The simulation results are presented and compared with existing methods, and the efficacy of the proposed method is verified.

  9. Analytical Verifications in Cryogenic Testing of NGST Advanced Mirror System Demonstrators

    NASA Technical Reports Server (NTRS)

    Cummings, Ramona; Levine, Marie; VanBuren, Dave; Kegley, Jeff; Green, Joseph; Hadaway, James; Presson, Joan; Cline, Todd; Stahl, H. Philip (Technical Monitor)

    2002-01-01

    Ground based testing is a critical and costly part of component, assembly, and system verifications of large space telescopes. At such tests, however, with integral teamwork by planners, analysts, and test personnel, segments can be included to validate specific analytical parameters and algorithms at relatively low additional cost. This paper opens with strategy of analytical verification segments added to vacuum cryogenic testing of Advanced Mirror System Demonstrator (AMSD) assemblies. These AMSD assemblies incorporate material and architecture concepts being considered in the Next Generation Space Telescope (NGST) design. The test segments for workmanship testing, cold survivability, and cold operation optical throughput are supplemented by segments for analytical verifications of specific structural, thermal, and optical parameters. Utilizing integrated modeling and separate materials testing, the paper continues with support plan for analyses, data, and observation requirements during the AMSD testing, currently slated for late calendar year 2002 to mid calendar year 2003. The paper includes anomaly resolution as gleaned by authors from similar analytical verification support of a previous large space telescope, then closes with draft of plans for parameter extrapolations, to form a well-verified portion of the integrated modeling being done for NGST performance predictions.

  10. Estimating winter wheat phenological parameters: Implications for crop modeling

    USDA-ARS?s Scientific Manuscript database

    Crop parameters, such as the timing of developmental events, are critical for accurate simulation results in crop simulation models, yet uncertainty often exists in determining the parameters. Factors contributing to the uncertainty include: a) sources of variation within a plant (i.e., within diffe...

  11. Genetic parameters for test day milk yields of first lactation Holstein cows by random regression models.

    PubMed

    de Melo, C M R; Packer, I U; Costa, C N; Machado, P F

    2007-03-01

    Covariance components for test day milk yield using 263 390 first lactation records of 32 448 Holstein cows were estimated using random regression animal models by restricted maximum likelihood. Three functions were used to adjust the lactation curve: the five-parameter logarithmic Ali and Schaeffer function (AS), the three-parameter exponential Wilmink function in its standard form (W) and in a modified form (W*), by reducing the range of covariate, and the combination of Legendre polynomial and W (LEG+W). Heterogeneous residual variance (RV) for different classes (4 and 29) of days in milk was considered in adjusting the functions. Estimates of RV were quite similar, rating from 4.15 to 5.29 kg2. Heritability estimates for AS (0.29 to 0.42), LEG+W (0.28 to 0.42) and W* (0.33 to 0.40) were similar, but heritability estimates used W (0.25 to 0.65) were highest than those estimated by the other functions, particularly at the end of lactation. Genetic correlations between milk yield on consecutive test days were close to unity, but decreased as the interval between test days increased. The AS function with homogeneous RV model had the best fit among those evaluated.

  12. Results From F-18B Stability and Control Parameter Estimation Flight Tests at High Dynamic Pressures

    NASA Technical Reports Server (NTRS)

    Moes, Timothy R.; Noffz, Gregory K.; Iliff, Kenneth W.

    2000-01-01

    A maximum-likelihood output-error parameter estimation technique has been used to obtain stability and control derivatives for the NASA F-18B Systems Research Aircraft. This work has been performed to support flight testing of the active aeroelastic wing (AAW) F-18A project. The goal of this research is to obtain baseline F-18 stability and control derivatives that will form the foundation of the aerodynamic model for the AAW aircraft configuration. Flight data have been obtained at Mach numbers between 0.85 and 1.30 and at dynamic pressures ranging between 600 and 1500 lbf/sq ft. At each test condition, longitudinal and lateral-directional doublets have been performed using an automated onboard excitation system. The doublet maneuver consists of a series of single-surface inputs so that individual control-surface motions cannot be correlated with other control-surface motions. Flight test results have shown that several stability and control derivatives are significantly different than prescribed by the F-18B aerodynamic model. This report defines the parameter estimation technique used, presents stability and control derivative results, compares the results with predictions based on the current F-18B aerodynamic model, and shows improvements to the nonlinear simulation using updated derivatives from this research.

  13. A Test of the Critical Period Hypothesis for Language Learning

    ERIC Educational Resources Information Center

    Chiswick, Barry R.; Miller, Paul W.

    2008-01-01

    A critical period for language learning is often defined as a sharp decline in learning outcomes with age. This study examines the relevance of the critical period for English-speaking proficiency among immigrants in the USA. It uses microdata from the 2000 US Census, a model of language acquisition and a flexible specification of an estimating…

  14. Critical need for MFE: the Alcator DX advanced divertor test facility

    NASA Astrophysics Data System (ADS)

    Vieira, R.; Labombard, B.; Marmar, E.; Irby, J.; Wolf, S.; Bonoli, P.; Fiore, C.; Granetz, R.; Greenwald, M.; Hutchinson, I.; Hubbard, A.; Hughes, J.; Lin, Y.; Lipschultz, B.; Parker, R.; Porkolab, M.; Reinke, M.; Rice, J.; Shiraiwa, S.; Terry, J.; Theiler, C.; Wallace, G.; White, A.; Whyte, D.; Wukitch, S.

    2013-10-01

    Three critical challenges must be met before a steady-state, power-producing fusion reactor can be realized: how to (1) safely handle extreme plasma exhaust power, (2) completely suppress material erosion at divertor targets and (3) do this while maintaining a burning plasma core. Advanced divertors such as ``Super X'' and ``X-point target'' may allow a fully detached, low temperature plasma to be produced in the divertor while maintaining a hot boundary layer around a clean plasma core - a potential game-changer for magnetic fusion. No facility currently exists to test these ideas at the required parallel heat flux densities. Alcator DX will be a national facility, employing the high magnetic field technology of Alcator combined with high-power ICRH and LHCD to test advanced divertor concepts at FNSF/DEMO power exhaust densities and plasma pressures. Its extended vacuum vessel contains divertor cassettes with poloidal field coils for conventional, snowflake, super-X and X-point target geometries. Divertor and core plasma performance will be explored in regimes inaccessible in conventional devices. Reactor relevant ICRF and LH drivers will be developed, utilizing high-field side launch platforms for low PMI. Alcator DX will inform the conceptual development and accelerate the readiness-for-deployment of next-step fusion facilities.

  15. Critical fluid light scattering

    NASA Technical Reports Server (NTRS)

    Gammon, Robert W.

    1988-01-01

    The objective is to measure the decay rates of critical density fluctuations in a simple fluid (xenon) very near its liquid-vapor critical point using laser light scattering and photon correlation spectroscopy. Such experiments were severely limited on Earth by the presence of gravity which causes large density gradients in the sample when the compressibility diverges approaching the critical point. The goal is to measure fluctuation decay rates at least two decades closer to the critical point than is possible on earth, with a resolution of 3 microK. This will require loading the sample to 0.1 percent of the critical density and taking data as close as 100 microK to the critical temperature. The minimum mission time of 100 hours will allow a complete range of temperature points to be covered, limited by the thermal response of the sample. Other technical problems have to be addressed such as multiple scattering and the effect of wetting layers. The experiment entails measurement of the scattering intensity fluctuation decay rate at two angles for each temperature and simultaneously recording the scattering intensities and sample turbidity (from the transmission). The analyzed intensity and turbidity data gives the correlation length at each temperature and locates the critical temperature. The fluctuation decay rate data from these measurements will provide a severe test of the generalized hydrodynamic theories of transport coefficients in the critical regions. When compared to equivalent data from binary liquid critical mixtures they will test the universality of critical dynamics.

  16. The Ideologies of American Social Critics: An Empirical Test of Kadushin's Theory

    ERIC Educational Resources Information Center

    Simon, David R.

    1977-01-01

    Examines Kadushin's earlier empirical efforts to determine the leading social critics and organizations of social criticism in America and investigates his theory through content analysis of leading journals of social criticism. (MH)

  17. PROTEIN NEEDS OF CRITICALLY ILL PATIENTS RECEIVING PARENTERAL NUTRITION.

    PubMed

    Germano Borges de Oliveira Nascimento Freitas, Renata; Negrão Nogueira, Roberto José; Hessel, Gabriel

    2015-07-01

    assess whether the current protein intake recommendations may improve the biochemical parameters of critical patients receiving parenteral nutrition. longitudinal study with three evaluations made (during the first 72 hours, on the 7th and the 14th days of PN). The following tests were applied: albumin, C-reactive protein, prealbumin, total cholesterol, HDL, triglycerides, lymphocytes, and glutathione peroxidase. The severity was determined by SOFA. The statistical analysis included the Spearman and Mann-Whitney tests, as well as ANOVA (analysis of variance). among the 53 patients evaluated, 20 (37.74%) died. The mean calorie was 24.68 ± 9.78 kcal/kg (beginning of PN), 26.49 ± 8.89 kcal/kg (3rd to 7th days of PN), and 30.9 ± 12.19 kcal/kg (7th to 14th days of PN). The mean protein was 1.19 ± 0.44 g/kcal/kg (first 72 hours of PN), 1.29 ± 0.44 g/kcal/kg (3rd to 7th days of PN) and 1.49 ± 0.69 g/kcal/kg (7th to 14th days of PN). Prealbumin, albumin, total cholesterol and HDL were below the reference values, while the CRP levels were high. Throughout the three evaluation times, there was no a significant improvement on the levels of laboratory examinations. A strong and negative correlation was found between SOFA and prealbumin (r = -0.64, p = 0.05). the protein offer, according to the traditional recommendations, was not enough to improve the biochemical parameters of critical patients undergoing parenteral nutrition. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  18. Parameter Optimization of PAL-XFEL Injector

    NASA Astrophysics Data System (ADS)

    Lee, Jaehyun; Ko, In Soo; Han, Jang-Hui; Hong, Juho; Yang, Haeryong; Min, Chang Ki; Kang, Heung-Sik

    2018-05-01

    A photoinjector is used as the electron source to generate a high peak current and low emittance beam for an X-ray free electron laser (FEL). The beam emittance is one of the critical parameters to determine the FEL performance together with the slice energy spread and the peak current. The Pohang Accelerator Laboratory X-ray Free Electron Laser (PAL-XFEL) was constructed in 2015, and the beam commissioning was carried out in spring 2016. The injector is running routinely for PAL-XFEL user operation. The operational parameters of the injector have been optimized experimentally, and these are somewhat different from the originally designed ones. Therefore, we study numerically the injector parameters based on the empirically optimized parameters and review the present operating condition.

  19. Experimental Data from the Benchmark SuperCritical Wing Wind Tunnel Test on an Oscillating Turntable

    NASA Technical Reports Server (NTRS)

    Heeg, Jennifer; Piatak, David J.

    2013-01-01

    The Benchmark SuperCritical Wing (BSCW) wind tunnel model served as a semi-blind testcase for the 2012 AIAA Aeroelastic Prediction Workshop (AePW). The BSCW was chosen as a testcase due to its geometric simplicity and flow physics complexity. The data sets examined include unforced system information and forced pitching oscillations. The aerodynamic challenges presented by this AePW testcase include a strong shock that was observed to be unsteady for even the unforced system cases, shock-induced separation and trailing edge separation. The current paper quantifies these characteristics at the AePW test condition and at a suggested benchmarking test condition. General characteristics of the model's behavior are examined for the entire available data set.

  20. A Systematic Approach of Employing Quality by Design Principles: Risk Assessment and Design of Experiments to Demonstrate Process Understanding and Identify the Critical Process Parameters for Coating of the Ethylcellulose Pseudolatex Dispersion Using Non-Conventional Fluid Bed Process.

    PubMed

    Kothari, Bhaveshkumar H; Fahmy, Raafat; Claycamp, H Gregg; Moore, Christine M V; Chatterjee, Sharmista; Hoag, Stephen W

    2017-05-01

    The goal of this study was to utilize risk assessment techniques and statistical design of experiments (DoE) to gain process understanding and to identify critical process parameters for the manufacture of controlled release multiparticulate beads using a novel disk-jet fluid bed technology. The material attributes and process parameters were systematically assessed using the Ishikawa fish bone diagram and failure mode and effect analysis (FMEA) risk assessment methods. The high risk attributes identified by the FMEA analysis were further explored using resolution V fractional factorial design. To gain an understanding of the processing parameters, a resolution V fractional factorial study was conducted. Using knowledge gained from the resolution V study, a resolution IV fractional factorial study was conducted; the purpose of this IV study was to identify the critical process parameters (CPP) that impact the critical quality attributes and understand the influence of these parameters on film formation. For both studies, the microclimate, atomization pressure, inlet air volume, product temperature (during spraying and curing), curing time, and percent solids in the coating solutions were studied. The responses evaluated were percent agglomeration, percent fines, percent yield, bead aspect ratio, median particle size diameter (d50), assay, and drug release rate. Pyrobuttons® were used to record real-time temperature and humidity changes in the fluid bed. The risk assessment methods and process analytical tools helped to understand the novel disk-jet technology and to systematically develop models of the coating process parameters like process efficiency and the extent of curing during the coating process.

  1. Which hemodynamic parameter predicts nitroglycerin-potentiated head-up tilt test response?

    PubMed

    Russo, Vincenzo; Papa, Andrea Antonio; Ciardiello, Carmine; Rago, Anna; Proietti, Riccardo; Calabrò, Paolo; Russo, Maria Giovanna; Nigro, Gerardo

    2015-04-01

    The aim of our study was to identify the early hemodynamic predictors of head-up tilt test (HUTT) outcome in healthy patients with recurrent unexplained syncope. The study involved 95 patients (mean age 38 ± 15; 42 male) who were referred for the evaluation of the syncopal episodes from October 2012 to May 2013. According to the nitroglycerin-potentiated diagnostic tilt test response, the study population was divided into two groups: HUTT+ Group (61 patients, mean age 37 ± 10; 27 male) and HUTT- Group (34 patients, mean age 38 ± 11; 15 male) with no tilt-induced syncope. Finger arterial blood pressure (BP) was recorded during tilt testing. Left ventricular stroke volume (SV), cardiac output (CO), and total peripheral resistance (TPR) were computed from the pressure pulsations. After nitroglycerin administration, the HUTT+ Group showed a significant increase in heart rate (92.0 ± 7.3 beats/min vs 68.9 ± 8.7 beats/min, P < 0.0001), with well-maintained systolic BP (111.6 ± 14.1 mm Hg vs 108.8 ± 11.5 mm Hg; P = 0.332) and diastolic BP (66.1 ± 8.5 mm Hg vs 63.1 ± 6.9 mm Hg; P = 0.0913); a significant decrease in SV (53.9 ± 8.0 mL vs 78.6 ± 8.2 mL; P < 0.0001) and CO (4.0 ± 0.5 L/min vs 5.8 ± 1.0 L/min; P < 0.001), and a significant increase in TPR (1.3 ± 0.3 U vs 0.9 ± 0.2 U, P < 0.0011). We tested three hemodynamic parameters (SV, CO, and TPR) as predictors of positive tilt test response with receiver-operating characteristic curve analysis. Our results show that, 2 minutes after nitroglycerin administration, a statistically significant decrease of SV values (<67 mL) strongly predicts (area under the curve, 0.985; P < 0.0001) the HUTT-positive response in healthy patients with recurrent unexplained syncope. © 2015 Wiley Periodicals, Inc.

  2. Hydrological parameter estimations from a conservative tracer test with variable-density effects at the Boise Hydrogeophysical Research Site

    NASA Astrophysics Data System (ADS)

    Dafflon, B.; Barrash, W.; Cardiff, M.; Johnson, T. C.

    2011-12-01

    Reliable predictions of groundwater flow and solute transport require an estimation of the detailed distribution of the parameters (e.g., hydraulic conductivity, effective porosity) controlling these processes. However, such parameters are difficult to estimate because of the inaccessibility and complexity of the subsurface. In this regard, developments in parameter estimation techniques and investigations of field experiments are still challenging and necessary to improve our understanding and the prediction of hydrological processes. Here we analyze a conservative tracer test conducted at the Boise Hydrogeophysical Research Site in 2001 in a heterogeneous unconfined fluvial aquifer. Some relevant characteristics of this test include: variable-density (sinking) effects because of the injection concentration of the bromide tracer, the relatively small size of the experiment, and the availability of various sources of geophysical and hydrological information. The information contained in this experiment is evaluated through several parameter estimation approaches, including a grid-search-based strategy, stochastic simulation of hydrological property distributions, and deterministic inversion using regularization and pilot-point techniques. Doing this allows us to investigate hydraulic conductivity and effective porosity distributions and to compare the effects of assumptions from several methods and parameterizations. Our results provide new insights into the understanding of variable-density transport processes and the hydrological relevance of incorporating various sources of information in parameter estimation approaches. Among others, the variable-density effect and the effective porosity distribution, as well as their coupling with the hydraulic conductivity structure, are seen to be significant in the transport process. The results also show that assumed prior information can strongly influence the estimated distributions of hydrological properties.

  3. Synaptic Plasticity Enables Adaptive Self-Tuning Critical Networks

    PubMed Central

    Stepp, Nigel; Plenz, Dietmar; Srinivasa, Narayan

    2015-01-01

    During rest, the mammalian cortex displays spontaneous neural activity. Spiking of single neurons during rest has been described as irregular and asynchronous. In contrast, recent in vivo and in vitro population measures of spontaneous activity, using the LFP, EEG, MEG or fMRI suggest that the default state of the cortex is critical, manifested by spontaneous, scale-invariant, cascades of activity known as neuronal avalanches. Criticality keeps a network poised for optimal information processing, but this view seems to be difficult to reconcile with apparently irregular single neuron spiking. Here, we simulate a 10,000 neuron, deterministic, plastic network of spiking neurons. We show that a combination of short- and long-term synaptic plasticity enables these networks to exhibit criticality in the face of intrinsic, i.e. self-sustained, asynchronous spiking. Brief external perturbations lead to adaptive, long-term modification of intrinsic network connectivity through long-term excitatory plasticity, whereas long-term inhibitory plasticity enables rapid self-tuning of the network back to a critical state. The critical state is characterized by a branching parameter oscillating around unity, a critical exponent close to -3/2 and a long tail distribution of a self-similarity parameter between 0.5 and 1. PMID:25590427

  4. Lead-acid batteries in micro-hybrid applications. Part II. Test proposal

    NASA Astrophysics Data System (ADS)

    Schaeck, S.; Stoermer, A. O.; Albers, J.; Weirather-Koestner, D.; Kabza, H.

    In the first part of this work [1] selected key parameters for applying lead-acid (LA) batteries in micro-hybrid power systems (MHPS) were investigated. Main results are integrated in an accelerated, comprehensive test proposal presented here. The test proposal aims at a realistic representation of the pSoC operation regime, which is described in Refs. [1,6]. The test is designed to be sensitive with respect to dynamic charge acceptance (DCA) at partially discharged state (critical for regenerative braking) and the internal resistance at high-rate discharge (critical for idling stop applications). First results are presented for up-to-date valve-regulated LA batteries with absorbent glass mat (AGM) separators. The batteries are close to the limits of the first proposal of pass/fail-criteria. Also flooded batteries were tested; the first out of ten units failed already.

  5. Procedure for estimating stability and control parameters from flight test data by using maximum likelihood methods employing a real-time digital system

    NASA Technical Reports Server (NTRS)

    Grove, R. D.; Bowles, R. L.; Mayhew, S. C.

    1972-01-01

    A maximum likelihood parameter estimation procedure and program were developed for the extraction of the stability and control derivatives of aircraft from flight test data. Nonlinear six-degree-of-freedom equations describing aircraft dynamics were used to derive sensitivity equations for quasilinearization. The maximum likelihood function with quasilinearization was used to derive the parameter change equations, the covariance matrices for the parameters and measurement noise, and the performance index function. The maximum likelihood estimator was mechanized into an iterative estimation procedure utilizing a real time digital computer and graphic display system. This program was developed for 8 measured state variables and 40 parameters. Test cases were conducted with simulated data for validation of the estimation procedure and program. The program was applied to a V/STOL tilt wing aircraft, a military fighter airplane, and a light single engine airplane. The particular nonlinear equations of motion, derivation of the sensitivity equations, addition of accelerations into the algorithm, operational features of the real time digital system, and test cases are described.

  6. Performance validity testing in neuropsychology: a clinical guide, critical review, and update on a rapidly evolving literature.

    PubMed

    Lippa, Sara M

    2018-04-01

    Over the past two decades, there has been much research on measures of response bias and myriad measures have been validated in a variety of clinical and research samples. This critical review aims to guide clinicians through the use of performance validity tests (PVTs) from test selection and administration through test interpretation and feedback. Recommended cutoffs and relevant test operating characteristics are presented. Other important issues to consider during test selection, administration, interpretation, and feedback are discussed including order effects, coaching, impact on test data, and methods to combine measures and improve predictive power. When interpreting performance validity measures, neuropsychologists must use particular caution in cases of dementia, low intelligence, English as a second language/minority cultures, or low education. PVTs provide valuable information regarding response bias and, under the right circumstances, can provide excellent evidence of response bias. Only after consideration of the entire clinical picture, including validity test performance, can concrete determinations regarding the validity of test data be made.

  7. 28,000 Hour Xenon Hollow Cathode LifeTest Results

    NASA Technical Reports Server (NTRS)

    Sarver-Verhey, Timothy R.

    1997-01-01

    The International Space Station Plasma Contactor System requires a hollow cathode assembly (HCA) with a lifetime of at least 18,000 hours. Critical components of the HCA include the hollow cathode and electron emitter. A series of hollow cathode wear tests was performed which included a life test operated at the maximum current of the HCA. This test sought to verify the hollow cathode design and contamination control protocols. The life test accumulated 27,800 hours of operation before failing to ignite. The hollow cathode exhibited relatively small changes in operating parameters over the course of the test. This life test is the longest duration test of a high current xenon hollow cathode reported to date.

  8. Turbulent mixing of a critical fluid: The non-perturbative renormalization

    NASA Astrophysics Data System (ADS)

    Hnatič, M.; Kalagov, G.; Nalimov, M.

    2018-01-01

    Non-perturbative Renormalization Group (NPRG) technique is applied to a stochastical model of a non-conserved scalar order parameter near its critical point, subject to turbulent advection. The compressible advecting flow is modeled by a random Gaussian velocity field with zero mean and correlation function 〈υjυi 〉 ∼ (Pji⊥ + αPji∥) /k d + ζ. Depending on the relations between the parameters ζ, α and the space dimensionality d, the model reveals several types of scaling regimes. Some of them are well known (model A of equilibrium critical dynamics and linear passive scalar field advected by a random turbulent flow), but there is a new nonequilibrium regime (universality class) associated with new nontrivial fixed points of the renormalization group equations. We have obtained the phase diagram (d, ζ) of possible scaling regimes in the system. The physical point d = 3, ζ = 4 / 3 corresponding to three-dimensional fully developed Kolmogorov's turbulence, where critical fluctuations are irrelevant, is stable for α ≲ 2.26. Otherwise, in the case of "strong compressibility" α ≳ 2.26, the critical fluctuations of the order parameter become relevant for three-dimensional turbulence. Estimations of critical exponents for each scaling regime are presented.

  9. 30 CFR 7.45 - Critical characteristics

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.45 Critical characteristics The following critical characteristics shall be inspected or tested on each battery assembly to... terminations. (e) Strain relief devices for cables leaving boxes. (f) Type, location, and physical protection...

  10. 30 CFR 7.45 - Critical characteristics

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.45 Critical characteristics The following critical characteristics shall be inspected or tested on each battery assembly to... terminations. (e) Strain relief devices for cables leaving boxes. (f) Type, location, and physical protection...

  11. 30 CFR 7.45 - Critical characteristics

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Battery Assemblies § 7.45 Critical characteristics The following critical characteristics shall be inspected or tested on each battery assembly to... terminations. (e) Strain relief devices for cables leaving boxes. (f) Type, location, and physical protection...

  12. Beethoven recordings reviewed: a systematic method for mapping the content of music performance criticism

    PubMed Central

    Alessandri, Elena; Williamson, Victoria J.; Eiholzer, Hubert; Williamon, Aaron

    2015-01-01

    Critical reviews offer rich data that can be used to investigate how musical experiences are conceptualized by expert listeners. However, these data also present significant challenges in terms of organization, analysis, and interpretation. This study presents a new systematic method for examining written responses to music, tested on a substantial corpus of music criticism. One hundred critical reviews of Beethoven’s piano sonata recordings, published in the Gramophone between August 1934 and July 2010, were selected using in-depth data reduction (qualitative/quantitative approach). The texts were then examined using thematic analysis in order to generate a visual descriptive model of expert critical review. This model reveals how the concept of evaluation permeates critical review. It also distinguishes between two types of descriptors. The first characterizes the performance in terms of specific actions or features of the musical sound (musical parameters, technique, and energy); the second appeals to higher-order properties (artistic style, character and emotion, musical structure, communicativeness) or assumed performer qualities (understanding, intentionality, spontaneity, sensibility, control, and care). The new model provides a methodological guide and conceptual basis for future studies of critical review in any genre. PMID:25741295

  13. Beethoven recordings reviewed: a systematic method for mapping the content of music performance criticism.

    PubMed

    Alessandri, Elena; Williamson, Victoria J; Eiholzer, Hubert; Williamon, Aaron

    2015-01-01

    Critical reviews offer rich data that can be used to investigate how musical experiences are conceptualized by expert listeners. However, these data also present significant challenges in terms of organization, analysis, and interpretation. This study presents a new systematic method for examining written responses to music, tested on a substantial corpus of music criticism. One hundred critical reviews of Beethoven's piano sonata recordings, published in the Gramophone between August 1934 and July 2010, were selected using in-depth data reduction (qualitative/quantitative approach). The texts were then examined using thematic analysis in order to generate a visual descriptive model of expert critical review. This model reveals how the concept of evaluation permeates critical review. It also distinguishes between two types of descriptors. The first characterizes the performance in terms of specific actions or features of the musical sound (musical parameters, technique, and energy); the second appeals to higher-order properties (artistic style, character and emotion, musical structure, communicativeness) or assumed performer qualities (understanding, intentionality, spontaneity, sensibility, control, and care). The new model provides a methodological guide and conceptual basis for future studies of critical review in any genre.

  14. Evaluating Stress Physiology and Parasite Infection Parameters in the Translocation of Critically Endangered Woylies (Bettongia penicillata).

    PubMed

    Hing, Stephanie; Northover, Amy S; Narayan, Edward J; Wayne, Adrian F; Jones, Krista L; Keatley, Sarah; Thompson, R C Andrew; Godfrey, Stephanie S

    2017-03-01

    Translocation can be stressful for wildlife. Stress may be important in fauna translocation because it has been suggested that it can exacerbate the impact of infectious disease on translocated wildlife. However, few studies explore this hypothesis by measuring stress physiology and infection indices in parallel during wildlife translocations. We analysed faecal cortisol metabolite (FCM) concentration and endoparasite parameters (nematodes, coccidians and haemoparasites) in a critically endangered marsupial, the woylie (Bettongia penicillata), 1-3 months prior to translocation, at translocation, and 6 months later. FCM for both translocated and resident woylies was significantly higher after translocation compared to before or at translocation. In addition, body condition decreased with increasing FCM after translocation. These patterns in host condition and physiology may be indicative of translocation stress or stress associated with factors independent of the translocation. Parasite factors also influenced FCM in translocated woylies. When haemoparasites were detected, there was a significant negative relationship between strongyle egg count and FCM. This may reflect the influence of glucocorticoids on the immune response to micro- and macro-parasites. Our results indicate that host physiology and infection patterns can change significantly during translocation, but further investigation is required to determine how these patterns influence translocation success.

  15. Sorption testing and generalized composite surface complexation models for determining uranium sorption parameters at a proposed in-situ recovery site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Raymond H.; Truax, Ryan A.; Lankford, David A.

    Solid-phase iron concentrations and generalized composite surface complexation models were used to evaluate procedures in determining uranium sorption on oxidized aquifer material at a proposed U in situ recovery (ISR) site. At the proposed Dewey Burdock ISR site in South Dakota, USA, oxidized aquifer material occurs downgradient of the U ore zones. Solid-phase Fe concentrations did not explain our batch sorption test results,though total extracted Fe appeared to be positively correlated with overall measured U sorption. Batch sorption test results were used to develop generalized composite surface complexation models that incorporated the full genericsorption potential of each sample, without detailedmore » mineralogiccharacterization. The resultant models provide U sorption parameters (site densities and equilibrium constants) for reactive transport modeling. The generalized composite surface complexation sorption models were calibrated to batch sorption data from three oxidized core samples using inverse modeling, and gave larger sorption parameters than just U sorption on the measured solidphase Fe. These larger sorption parameters can significantly influence reactive transport modeling, potentially increasing U attenuation. Because of the limited number of calibration points, inverse modeling required the reduction of estimated parameters by fixing two parameters. The best-fit models used fixed values for equilibrium constants, with the sorption site densities being estimated by the inversion process. While these inverse routines did provide best-fit sorption parameters, local minima and correlated parameters might require further evaluation. Despite our limited number of proxy samples, the procedures presented provide a valuable methodology to consider for sites where metal sorption parameters are required. Furthermore, these sorption parameters can be used in reactive transport modeling to assess downgradient metal attenuation, especially when no other

  16. Sorption testing and generalized composite surface complexation models for determining uranium sorption parameters at a proposed in-situ recovery site

    DOE PAGES

    Johnson, Raymond H.; Truax, Ryan A.; Lankford, David A.; ...

    2016-02-03

    Solid-phase iron concentrations and generalized composite surface complexation models were used to evaluate procedures in determining uranium sorption on oxidized aquifer material at a proposed U in situ recovery (ISR) site. At the proposed Dewey Burdock ISR site in South Dakota, USA, oxidized aquifer material occurs downgradient of the U ore zones. Solid-phase Fe concentrations did not explain our batch sorption test results,though total extracted Fe appeared to be positively correlated with overall measured U sorption. Batch sorption test results were used to develop generalized composite surface complexation models that incorporated the full genericsorption potential of each sample, without detailedmore » mineralogiccharacterization. The resultant models provide U sorption parameters (site densities and equilibrium constants) for reactive transport modeling. The generalized composite surface complexation sorption models were calibrated to batch sorption data from three oxidized core samples using inverse modeling, and gave larger sorption parameters than just U sorption on the measured solidphase Fe. These larger sorption parameters can significantly influence reactive transport modeling, potentially increasing U attenuation. Because of the limited number of calibration points, inverse modeling required the reduction of estimated parameters by fixing two parameters. The best-fit models used fixed values for equilibrium constants, with the sorption site densities being estimated by the inversion process. While these inverse routines did provide best-fit sorption parameters, local minima and correlated parameters might require further evaluation. Despite our limited number of proxy samples, the procedures presented provide a valuable methodology to consider for sites where metal sorption parameters are required. Furthermore, these sorption parameters can be used in reactive transport modeling to assess downgradient metal attenuation, especially when no other

  17. A Geophysical Flow Experiment in a Compressible Critical Fluid

    NASA Technical Reports Server (NTRS)

    Hegseth, John; Garcia, Laudelino

    1996-01-01

    The first objective of this experiment is to build an experimental system in which, in analogy to a geophysical system, a compressible fluid in a spherical annulus becomes radially stratified in density through an A.C. electric field. When this density gradient is demonstrated, the system will be augmented so that the fluid can be driven by heating and rotation and tested in preparation for a microgravity experiment. This apparatus consists of a spherical capacitor filled with critical fluid in a temperature controlled environment. To make the fluid critical, the apparatus will be operated near the critical pressure, critical density, and critical temperature of the fluid. This will result in a highly compressible fluid because of the properties of the fluid near its critical point. A high voltage A.C. source applied across the capacitor will create a spherically symmetric central force because of the dielectric properties of the fluid in an electric field gradient. This central force will induce a spherically symmetric density gradient that is analogous to a geophysical fluid system. To generate such a density gradient the system must be small (approx. 1 inch diameter). This small cell will also be capable of driving the critical fluid by heating and rotation. Since a spherically symmetric density gradient can only be made in microgravity, another small cell, of the same geometry, will be built that uses incompressible fluid. The driving of the fluid by rotation and heating in these small cells will be developed. The resulting instabilities from the driving in these two systems will then be studied. The second objective is to study the pattern forming instabilities (bifurcations) resulting from the well controlled experimental conditions in the critical fluid cell. This experiment will come close to producing conditions that are geophysically similar and will be studied as the driving parameters are changed.

  18. Multi-parameter comparison of a standardized mixed meal tolerance test in healthy and type 2 diabetic subjects: the PhenFlex challenge.

    PubMed

    Wopereis, Suzan; Stroeve, Johanna H M; Stafleu, Annette; Bakker, Gertruud C M; Burggraaf, Jacobus; van Erk, Marjan J; Pellis, Linette; Boessen, Ruud; Kardinaal, Alwine A F; van Ommen, Ben

    2017-01-01

    A key feature of metabolic health is the ability to adapt upon dietary perturbations. Recently, it was shown that metabolic challenge tests in combination with the new generation biomarkers allow the simultaneous quantification of major metabolic health processes. Currently, applied challenge tests are largely non-standardized. A systematic review defined an optimal nutritional challenge test, the "PhenFlex test" (PFT). This study aimed to prove that PFT modulates all relevant processes governing metabolic health thereby allowing to distinguish subjects with different metabolic health status. Therefore, 20 healthy and 20 type 2 diabetic (T2D) male subjects were challenged both by PFT and oral glucose tolerance test (OGTT). During the 8-h response time course, 132 parameters were quantified that report on 26 metabolic processes distributed over 7 organs (gut, liver, adipose, pancreas, vasculature, muscle, kidney) and systemic stress. In healthy subjects, 110 of the 132 parameters showed a time course response. Patients with T2D showed 18 parameters to be significantly different after overnight fasting compared to healthy subjects, while 58 parameters were different in the post-challenge time course after the PFT. This demonstrates the added value of PFT in distinguishing subjects with different health status. The OGTT and PFT response was highly comparable for glucose metabolism as identical amounts of glucose were present in both challenge tests. Yet the PFT reports on additional processes, including vasculature, systemic stress, and metabolic flexibility. The PFT enables the quantification of all relevant metabolic processes involved in maintaining or regaining homeostasis of metabolic health. Studying both healthy subjects and subjects with impaired metabolic health showed that the PFT revealed new processes laying underneath health. This study provides the first evidence towards adopting the PFT as gold standard in nutrition research.

  19. A Critical Test of Self-Enhancement, Exposure, and Self-Categorization Explanations for First- and Third-Person Perceptions

    ERIC Educational Resources Information Center

    Reid, Scott A.; Byrne, Sahara; Brundidge, Jennifer S.; Shoham, Mirit D.; Marlow, Mikaela L.

    2007-01-01

    The third-person perception is the tendency for people to believe that others are more influenced by media content than themselves (W. P. Davison, 1983). The current study provides a critical test of self-enhancement, exposure, and self-categorization explanations for first- (i.e., self more influenced than others) and third-person perceptions.…

  20. Parametric Analysis of a Hover Test Vehicle using Advanced Test Generation and Data Analysis

    NASA Technical Reports Server (NTRS)

    Gundy-Burlet, Karen; Schumann, Johann; Menzies, Tim; Barrett, Tony

    2009-01-01

    Large complex aerospace systems are generally validated in regions local to anticipated operating points rather than through characterization of the entire feasible operational envelope of the system. This is due to the large parameter space, and complex, highly coupled nonlinear nature of the different systems that contribute to the performance of the aerospace system. We have addressed the factors deterring such an analysis by applying a combination of technologies to the area of flight envelop assessment. We utilize n-factor (2,3) combinatorial parameter variations to limit the number of cases, but still explore important interactions in the parameter space in a systematic fashion. The data generated is automatically analyzed through a combination of unsupervised learning using a Bayesian multivariate clustering technique (AutoBayes) and supervised learning of critical parameter ranges using the machine-learning tool TAR3, a treatment learner. Covariance analysis with scatter plots and likelihood contours are used to visualize correlations between simulation parameters and simulation results, a task that requires tool support, especially for large and complex models. We present results of simulation experiments for a cold-gas-powered hover test vehicle.

  1. Goodness-of-Fit Tests for Generalized Normal Distribution for Use in Hydrological Frequency Analysis

    NASA Astrophysics Data System (ADS)

    Das, Samiran

    2018-04-01

    The use of three-parameter generalized normal (GNO) as a hydrological frequency distribution is well recognized, but its application is limited due to unavailability of popular goodness-of-fit (GOF) test statistics. This study develops popular empirical distribution function (EDF)-based test statistics to investigate the goodness-of-fit of the GNO distribution. The focus is on the case most relevant to the hydrologist, namely, that in which the parameter values are unidentified and estimated from a sample using the method of L-moments. The widely used EDF tests such as Kolmogorov-Smirnov, Cramer von Mises, and Anderson-Darling (AD) are considered in this study. A modified version of AD, namely, the Modified Anderson-Darling (MAD) test, is also considered and its performance is assessed against other EDF tests using a power study that incorporates six specific Wakeby distributions (WA-1, WA-2, WA-3, WA-4, WA-5, and WA-6) as the alternative distributions. The critical values of the proposed test statistics are approximated using Monte Carlo techniques and are summarized in chart and regression equation form to show the dependence of shape parameter and sample size. The performance results obtained from the power study suggest that the AD and a variant of the MAD (MAD-L) are the most powerful tests. Finally, the study performs case studies involving annual maximum flow data of selected gauged sites from Irish and US catchments to show the application of the derived critical values and recommends further assessments to be carried out on flow data sets of rivers with various hydrological regimes.

  2. Global and critical test of the perturbation density-functional theory based on extensive simulation of Lennard-Jones fluid near an interface and in confined systems.

    PubMed

    Zhou, Shiqi; Jamnik, Andrej

    2005-09-22

    The structure of a Lennard-Jones (LJ) fluid subjected to diverse external fields maintaining the equilibrium with the bulk LJ fluid is studied on the basis of the third-order+second-order perturbation density-functional approximation (DFA). The chosen density and potential parameters for the bulk fluid correspond to the conditions situated at "dangerous" regions of the phase diagram, i.e., near the critical temperature or close to the gas-liquid coexistence curve. The accuracy of DFA predictions is tested against the results of a grand canonical ensemble Monte Carlo simulation. It is found that the DFA theory presented in this work performs successfully for the nonuniform LJ fluid only on the condition of high accuracy of the required bulk second-order direct correlation function. The present report further indicates that the proposed perturbation DFA is efficient and suitable for both supercritical and subcritical temperatures.

  3. Effects of psychological stress test on the cardiac response of public safety workers: alternative parameters to autonomic balance

    NASA Astrophysics Data System (ADS)

    Huerta-Franco, M. R.; Vargas-Luna, F. M.; Delgadillo-Holtfort, I.

    2015-01-01

    It is well known that public safety workers (PSW) face many stressful situations that yield them as high-risk population for suffering chronic stress diseases. In this multidisciplinary research the cardiac response to induced psychological stress by a short duration Stroop test was evaluated in 20 female and 19 male PSW, in order to compare traditionally used cardiac response parameters with alternative ones. Electrocardiograms have been recorded using the Eindhoven electrodes configuration for 1 min before, 3 min during and 1 min after the test. Signals analysis has been performed for the heart rate and the power spectra of its variability and of the variability of the amplitude of the R-wave, i.e. the highest peak of the electrocardiographic signal periodic sequence. The results demonstrated that the traditional autonomic balance index shows no significant differences between stages. In contrast, the median of the area of the power spectrum of the R-wave amplitude variability in the frequency region dominated by the autonomous nervous system (0.04-to-0.4 Hz) is the more sensitive parameter. Moreover, this parameter allows to identify gender differences consistent with those encountered in other studies.

  4. Evaluation for relationship among source parameters of underground nuclear tests in Northern Korean Peninsula

    NASA Astrophysics Data System (ADS)

    Kim, G.; Che, I. Y.

    2017-12-01

    We evaluated relationship among source parameters of underground nuclear tests in northern Korean Peninsula using regional seismic data. Dense global and regional seismic networks are incorporated to measure locations and origin times precisely. Location analyses show that distance among the locations is tiny on a regional scale. The tiny location-differences validate a linear model assumption. We estimated source spectral ratios by excluding path effects based spectral ratios of the observed seismograms. We estimated empirical relationship among depth of burials and yields based on theoretical source models.

  5. NASA Contractor Report: Guidelines for Proof Test Analysis

    NASA Technical Reports Server (NTRS)

    Chell, G. G.; McClung, R. C.; Kuhlman, C. J.; Russell, D. A.; Garr, K.; Donnelly, B.

    1997-01-01

    These Guidelines integrate state-of-the-art Elastic-Plastic Fracture Mechanics (EPFM) and proof test implementation issues into a comprehensive proof test analysis procedure in the form of a Road Map which identifies the types of data, fracture mechanics based parameters, and calculations needed to perform flaw screening and minimum proof load analyses of fracture critical components. Worked examples are presented to illustrate the application of the Road Map to proof test analysis. The state-of-the-art fracture technology employed in these Guidelines is based on the EPFM parameter, J, and a pictorial representation of a J fracture analysis, called the Failure Assessment Diagram (FAD) approach. The recommended fracture technology is validated using finite element J results, and laboratory and hardware fracture test results on the nickel-based superalloy IN-718, the aluminum alloy 2024-T351 1, and ferritic pressure vessel steels. In all cases the laboratory specimens and hardware failed by ductile mechanisms. Advanced proof test analyses involving probability analysis and Multiple Cycle Proof Testing (MCPT) are addressed. Finally, recommendations are provided on to how to account for the effects of the proof test overload on subsequent service fatigue and fracture behaviors.

  6. Use of computer-aided testing in the investigation of pilot response to critical in-flight events. Volume 2: Appendix

    NASA Technical Reports Server (NTRS)

    Rockwell, T. H.; Giffin, W. C.

    1982-01-01

    Computer displays using PLATO are illustrated. Diagnostic scenarios are described. A sample of subject data is presented. Destination diversion displays, a combined destination, diversion scenario, and critical in-flight event (CIFE) data collection/subject testing system are presented.

  7. Quasi-critical fluctuations: a novel state of matter?

    PubMed

    Bertel, Erminald

    2013-05-01

    Quasi-critical fluctuations occur close to critical points or close to continuous phase transitions. In three-dimensional systems, precision tuning is required to access the fluctuation regime. Lowering the dimensionality enhances the parameter space for quasi-critical fluctuations considerably. This enables one to make use of novel properties emerging in fluctuating systems, such as giant susceptibilities, Casimir forces or novel quasi-particle interactions. Examples are discussed ranging from simple metal-adsorbate systems to unconventional superconductivity in iron-based superconductors.

  8. Critical gravity in four dimensions.

    PubMed

    Lü, H; Pope, C N

    2011-05-06

    We study four-dimensional gravity theories that are rendered renormalizable by the inclusion of curvature-squared terms to the usual Einstein action with a cosmological constant. By choosing the parameters appropriately, the massive scalar mode can be eliminated and the massive spin-2 mode can become massless. This "critical" theory may be viewed as a four-dimensional analogue of chiral topologically massive gravity, or of critical "new massive gravity" with a cosmological constant, in three dimensions. We find that the on-shell energy for the remaining massless gravitons vanishes. There are also logarithmic spin-2 modes, which have positive energy. The mass and entropy of standard Schwarzschild-type black holes vanish. The critical theory might provide a consistent toy model for quantum gravity in four dimensions.

  9. The critical crossover at the n-hexane-water interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tikhonov, A. M., E-mail: tikhonov@kapitza.ras.r

    According to estimates of the parameters of the critical crossover in monolayers of long-chain alcohol molecules adsorbed at the n-hexane-water interface, all systems in which this phenomenon is observed are characterized by the same value of the critical exponent {nu} {approx} 1.8.

  10. Research on the critical parameters initialization of optical PMD compensator in high bit-rate systems

    NASA Astrophysics Data System (ADS)

    Zhao, Wenyu; Zhang, Haiyi; Ji, Yuefeng; Xu, Daxiong

    2004-05-01

    Based on the proposed polarization mode dispersion (PMD) compensation simulation model and statistical analysis method (Monte-Carlo), the critical parameters initialization of two typical optical domain PMD compensators, which include optical PMD method with fixed compensation differential group delay (DGD) and that with variable compensation DGD, are detailedly investigated by numerical method. In the simulation, the line PMD values are chosen as 3ps, 4ps and 5ps and run samples are set to 1000 in order to achieve statistical evaluation for PMD compensated systems, respectively. The simulation results show that for the PMD value pre-known systems, the value of the fixed DGD compensator should be set to 1.5~1.6 times of line PMD value in order to reach the optimum performance, but for the second kind of PMD compensator, the DGD range of lower limit should be 1.5~1.6 times of line PMD provided that of upper limit is set to 3 times of line PMD, if no effective ways are chosen to resolve the problem of local minimum in optimum process. Another conclusion can be drawn from the simulation is that, although the second PMD compensator holds higher PMD compensation performance, it will spend more feedback loops to look up the optimum DGD value in the real PMD compensation realization, and this will bring more requirements on adjustable DGD device, not only wider adjustable range, but rapid adjusting speed for real time PMD equalization.

  11. [Non-animal toxicology in the safety testing of chemicals].

    PubMed

    Heinonen, Tuula; Tähti, Hanna

    2013-01-01

    There is an urgent need to develop predictive test methods better than animal experiments for assessing the safety of chemical substances to man. According to today's vision this is achieved by using human cell based tissue and organ models. In the new testing strategy the toxic effects are assessed by the changes in the critical parameters of the cellular biochemical routes (AOP, adverse toxic outcome pathway-principle) in the target tissues. In vitro-tests are rapid and effective, and with them automation can be applied. The change in the testing paradigm is supported by all stakeholders: scientists, regulators and people concerned on animal welfare.

  12. Uncertainty quantification and propagation of errors of the Lennard-Jones 12-6 parameters for n-alkanes

    PubMed Central

    Knotts, Thomas A.

    2017-01-01

    Molecular simulation has the ability to predict various physical properties that are difficult to obtain experimentally. For example, we implement molecular simulation to predict the critical constants (i.e., critical temperature, critical density, critical pressure, and critical compressibility factor) for large n-alkanes that thermally decompose experimentally (as large as C48). Historically, molecular simulation has been viewed as a tool that is limited to providing qualitative insight. One key reason for this perceived weakness in molecular simulation is the difficulty to quantify the uncertainty in the results. This is because molecular simulations have many sources of uncertainty that propagate and are difficult to quantify. We investigate one of the most important sources of uncertainty, namely, the intermolecular force field parameters. Specifically, we quantify the uncertainty in the Lennard-Jones (LJ) 12-6 parameters for the CH4, CH3, and CH2 united-atom interaction sites. We then demonstrate how the uncertainties in the parameters lead to uncertainties in the saturated liquid density and critical constant values obtained from Gibbs Ensemble Monte Carlo simulation. Our results suggest that the uncertainties attributed to the LJ 12-6 parameters are small enough that quantitatively useful estimates of the saturated liquid density and the critical constants can be obtained from molecular simulation. PMID:28527455

  13. Literature: Developing Critical Awareness; Some Classroom-Tested Approaches.

    ERIC Educational Resources Information Center

    Matthews, Dorothy, Ed.

    1977-01-01

    This issue of the "Illinois English Bulletin" is devoted to developing critical awareness, through poetry, values, the elements of fiction, and literary study. The first section considers approaching narrative through the use of popular materials and includes two essays: "Grim Tales in the English Classroom" by Larry Danielson and "From the Comics…

  14. Investigation of mechanism and critical parameters for removal of arsenic from water using Zr-TiO2 composite.

    PubMed

    Anđelković, I; Amaizah, N R R; Marković, S B; Stanković, D; Marković, M; Kuzmanović, D; Roglić, G

    2017-09-01

    Using the microwave-hydrothermal method for the synthesis of composite, high surface density of hydroxyl groups, as an active adsorption sites for arsenic, was obtained. Adsorption mechanisms of As(III) and As(V) onto zirconium-doped titanium dioxide (Zr-TiO 2 ) were investigated and proposed using macroscopic and microscopic methods. Obtained results are suggesting inner-sphere and outer-sphere adsorption mechanisms for As(III) and As(V), respectively. This allowed us to identify parameters that are critical for the successful removal of arsenic from water, which is essential information for further optimization of the removal process. The composite was further applied for the removal of As(III) and As(V) from water in a dynamic flow through the reactor. Column study proved that the removal of both arsenic species below the value recommended by WHO can be achieved. Elution of As(III) and As(V) from the composite can be done by using small amounts of 0.01 M NaOH solution resulting in preconcentration of arsenic species and possible multiple usage of composite.

  15. Automatic parameter selection for feature-based multi-sensor image registration

    NASA Astrophysics Data System (ADS)

    DelMarco, Stephen; Tom, Victor; Webb, Helen; Chao, Alan

    2006-05-01

    Accurate image registration is critical for applications such as precision targeting, geo-location, change-detection, surveillance, and remote sensing. However, the increasing volume of image data is exceeding the current capacity of human analysts to perform manual registration. This image data glut necessitates the development of automated approaches to image registration, including algorithm parameter value selection. Proper parameter value selection is crucial to the success of registration techniques. The appropriate algorithm parameters can be highly scene and sensor dependent. Therefore, robust algorithm parameter value selection approaches are a critical component of an end-to-end image registration algorithm. In previous work, we developed a general framework for multisensor image registration which includes feature-based registration approaches. In this work we examine the problem of automated parameter selection. We apply the automated parameter selection approach of Yitzhaky and Peli to select parameters for feature-based registration of multisensor image data. The approach consists of generating multiple feature-detected images by sweeping over parameter combinations and using these images to generate estimated ground truth. The feature-detected images are compared to the estimated ground truth images to generate ROC points associated with each parameter combination. We develop a strategy for selecting the optimal parameter set by choosing the parameter combination corresponding to the optimal ROC point. We present numerical results showing the effectiveness of the approach using registration of collected SAR data to reference EO data.

  16. Dynamical Crossovers in Prethermal Critical States.

    PubMed

    Chiocchetta, Alessio; Gambassi, Andrea; Diehl, Sebastian; Marino, Jamir

    2017-03-31

    We study the prethermal dynamics of an interacting quantum field theory with an N-component order parameter and O(N) symmetry, suddenly quenched in the vicinity of a dynamical critical point. Depending on the initial conditions, the evolution of the order parameter, and of the response and correlation functions, can exhibit a temporal crossover between universal dynamical scaling regimes governed, respectively, by a quantum and a classical prethermal fixed point, as well as a crossover from a Gaussian to a non-Gaussian prethermal dynamical scaling. Together with a recent experiment, this suggests that quenches may be used in order to explore the rich variety of dynamical critical points occurring in the nonequilibrium dynamics of a quantum many-body system. We illustrate this fact by using a combination of renormalization group techniques and a nonperturbative large-N limit.

  17. Testing and Performance Analysis of the Multichannel Error Correction Code Decoder

    NASA Technical Reports Server (NTRS)

    Soni, Nitin J.

    1996-01-01

    This report provides the test results and performance analysis of the multichannel error correction code decoder (MED) system for a regenerative satellite with asynchronous, frequency-division multiple access (FDMA) uplink channels. It discusses the system performance relative to various critical parameters: the coding length, data pattern, unique word value, unique word threshold, and adjacent-channel interference. Testing was performed under laboratory conditions and used a computer control interface with specifically developed control software to vary these parameters. Needed technologies - the high-speed Bose Chaudhuri-Hocquenghem (BCH) codec from Harris Corporation and the TRW multichannel demultiplexer/demodulator (MCDD) - were fully integrated into the mesh very small aperture terminal (VSAT) onboard processing architecture and were demonstrated.

  18. Saline suppression test parameters may predict bilateral subtypes of primary aldosteronism.

    PubMed

    Hashimura, Hikaru; Shen, Jimmy; Fuller, Peter J; Chee, Nicholas Y N; Doery, James C G; Chong, Winston; Choy, Kay Weng; Gwini, Stella May; Yang, Jun

    2018-06-06

    The saline suppression test (SST) serves to confirm the diagnosis of primary aldosteronism (PA) while adrenal vein sampling (AVS) is used to determine whether the aldosterone hypersecretion is unilateral or bilateral. An accurate prediction of bilateral PA based on SST results could reduce the need for AVS. We sought to identify SST parameters that reliably predict bilateral PA. The results from 121 patients undergoing SSTs at Monash Health from January 2010 to January 2018 including screening blood tests, imaging, AVS and histopathology results were evaluated. Patients were subtyped into unilateral or bilateral PA based on AVS and surgical outcomes. Of 113 patients with confirmed PA, 33 had unilateral disease while 42 had bilateral disease. In those with bilateral disease, plasma aldosterone concentration (PAC) was significantly lower post-SST, together with a significant fall in the aldosterone-renin ratio (ARR). The combination of PAC <300 pmol/L and a reduction in ARR post-SST provided 96.8% specificity in predicting bilateral disease. Eighteen out of 39 patients (49%) with bilateral PA could have avoided AVS using these criteria. A combination of PAC <300 pmol/L and a lower ARR post-SST could reliably predict bilateral PA. An independent cohort will be needed to validate these findings. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  19. Estimation of parameters of dose volume models and their confidence limits

    NASA Astrophysics Data System (ADS)

    van Luijk, P.; Delvigne, T. C.; Schilstra, C.; Schippers, J. M.

    2003-07-01

    Predictions of the normal-tissue complication probability (NTCP) for the ranking of treatment plans are based on fits of dose-volume models to clinical and/or experimental data. In the literature several different fit methods are used. In this work frequently used methods and techniques to fit NTCP models to dose response data for establishing dose-volume effects, are discussed. The techniques are tested for their usability with dose-volume data and NTCP models. Different methods to estimate the confidence intervals of the model parameters are part of this study. From a critical-volume (CV) model with biologically realistic parameters a primary dataset was generated, serving as the reference for this study and describable by the NTCP model. The CV model was fitted to this dataset. From the resulting parameters and the CV model, 1000 secondary datasets were generated by Monte Carlo simulation. All secondary datasets were fitted to obtain 1000 parameter sets of the CV model. Thus the 'real' spread in fit results due to statistical spreading in the data is obtained and has been compared with estimates of the confidence intervals obtained by different methods applied to the primary dataset. The confidence limits of the parameters of one dataset were estimated using the methods, employing the covariance matrix, the jackknife method and directly from the likelihood landscape. These results were compared with the spread of the parameters, obtained from the secondary parameter sets. For the estimation of confidence intervals on NTCP predictions, three methods were tested. Firstly, propagation of errors using the covariance matrix was used. Secondly, the meaning of the width of a bundle of curves that resulted from parameters that were within the one standard deviation region in the likelihood space was investigated. Thirdly, many parameter sets and their likelihood were used to create a likelihood-weighted probability distribution of the NTCP. It is concluded that for the

  20. The Mach number of the cosmic flow - A critical test for current theories

    NASA Technical Reports Server (NTRS)

    Ostriker, Jeremiah P.; Suto, Yusushi

    1990-01-01

    A new cosmological, self-contained test using the ratio of mean velocity and the velocity dispersion in the mean flow frame of a group of test objects is presented. To allow comparison with linear theory, the velocity field must first be smoothed on a suitable scale. In the context of linear perturbation theory, the Mach number M(R) which measures the ratio of power on scales larger than to scales smaller than the patch size R, is independent of the perturbation amplitude and also of bias. An apparent inconsistency is found for standard values of power-law index n = 1 and cosmological density parameter Omega = 1, when comparing values of M(R) predicted by popular models with tentative available observations. Nonstandard models based on adiabatic perturbations with either negative n or small Omega value also fail, due to creation of unacceptably large microwave background fluctuations.

  1. Alternatives to conventional evaluation of rideability in horse performance tests: suitability of rein tension and behavioural parameters.

    PubMed

    König von Borstel, Uta; Glißman, Chantal

    2014-01-01

    Rideability, i.e. the ease and comfort with which a horse can be ridden, is considered to be one of the most important traits in riding horses. However, at present rideability is evaluated rather subjectively in breeding horse performance tests. The aim of the present study was to evaluate the role horse behaviour as well as degree and quality of rein tension might play in judges' evaluation of horses' rideability. Mares (n=33) and stallions (n=13) from two different mare- and one stallion-testing station were observed twice during their performance test dressage training. During these rides, rein tension was measured continuously, and frequency of behaviour patterns such as head-tossing, tail swishing, and snorting was recorded. Rein tension parameters showed reasonable repeatabilities within horse-rider pairs (e.g. mean rein tension: r(2)=0.61 ± 0.11; variance of rein tension: r(2)=0.52 ± 0.14). Regression analysis revealed that a larger proportion of variance in rideability scores could be explained by maximum (17%), mean (16%) and variance (15%) of rein tension compared to horses' or riders' behavioural parameters (tail-swishing: 5% and rider's use of hands: 5%, respectively). According to mixed model analysis, rideability scores dropped (all P<0.05) with increasing mean, maximum and variability in rein tension (e.g. -0.37 ± 0.14 scores per additional 10 Newton in mean tension). However, mean rein tension differed between testing stations (P<0.0001) ranging between 9.1 ± 1.6 N in one station and 21.7 ± 1.3 N in another station. These results indicate that quantity and consistency of rein tension is either directly or indirectly an important factor for judges to derive rideability scores. Given the importance of rein tension parameters to both rider comfort and horse welfare, potentially, measurements of rein tension along with behaviour observations assessing the quality of rein contact (e.g. distinguishing a light contact from attempts to evade contact

  2. Critical behavior of phase interfaces in porous media: Analysis of scaling properties with the use of noncoherent and coherent light

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zimnyakov, D. A., E-mail: zimnykov@sgu.ru; Sadovoi, A. V.; Vilenskii, M. A.

    2009-02-15

    Image sequences of the surface of disordered layers of porous medium (paper) obtained under noncoherent and coherent illumination during capillary rise of a liquid are analyzed. As a result, principles that govern the critical behavior of the interface between liquid and gaseous phases during its pinning are established. By a cumulant analysis of speckle-modulated images of the surface and by the statistical analysis of binarized difference images of the surface under noncoherent illumination, it is shown that the macroscopic dynamics of the interface at the stage of pinning is mainly controlled by the power law dependence of the appearance ratemore » of local instabilities (avalanches) of the interface on the critical parameter, whereas the growth dynamics of the local instabilities is controlled by the diffusion of a liquid in a layer and weakly depends on the critical parameter. A phenomenological model is proposed for the macroscopic dynamics of the phase interface for interpreting experimental data. The values of critical indices are determined that characterize the samples under test within this model. These values are compared with the results of numerical simulation for discrete models of directed percolation corresponding to the Kardar-Parisi-Zhang equation.« less

  3. Critical N = (1, 1) general massive supergravity

    NASA Astrophysics Data System (ADS)

    Deger, Nihat Sadik; Moutsopoulos, George; Rosseel, Jan

    2018-04-01

    In this paper we study the supermultiplet structure of N = (1, 1) General Massive Supergravity at non-critical and critical points of its parameter space. To do this, we first linearize the theory around its maximally supersymmetric AdS3 vacuum and obtain the full linearized Lagrangian including fermionic terms. At generic values, linearized modes can be organized as two massless and 2 massive multiplets where supersymmetry relates them in the standard way. At critical points logarithmic modes appear and we find that in three of such points some of the supersymmetry transformations are non-invertible in logarithmic multiplets. However, in the fourth critical point, there is a massive logarithmic multiplet with invertible supersymmetry transformations.

  4. Consistency of QSAR models: Correct split of training and test sets, ranking of models and performance parameters.

    PubMed

    Rácz, A; Bajusz, D; Héberger, K

    2015-01-01

    Recent implementations of QSAR modelling software provide the user with numerous models and a wealth of information. In this work, we provide some guidance on how one should interpret the results of QSAR modelling, compare and assess the resulting models, and select the best and most consistent ones. Two QSAR datasets are applied as case studies for the comparison of model performance parameters and model selection methods. We demonstrate the capabilities of sum of ranking differences (SRD) in model selection and ranking, and identify the best performance indicators and models. While the exchange of the original training and (external) test sets does not affect the ranking of performance parameters, it provides improved models in certain cases (despite the lower number of molecules in the training set). Performance parameters for external validation are substantially separated from the other merits in SRD analyses, highlighting their value in data fusion.

  5. Liquid Nitrogen Removal of Critical Aerospace Materials

    NASA Technical Reports Server (NTRS)

    Noah, Donald E.; Merrick, Jason; Hayes, Paul W.

    2005-01-01

    Identification of innovative solutions to unique materials problems is an every-day quest for members of the aerospace community. Finding a technique that will minimize costs, maximize throughput, and generate quality results is always the target. United Space Alliance Materials Engineers recently conducted such a search in their drive to return the Space Shuttle fleet to operational status. The removal of high performance thermal coatings from solid rocket motors represents a formidable task during post flight disassembly on reusable expended hardware. The removal of these coatings from unfired motors increases the complexity and safety requirements while reducing the available facilities and approved processes. A temporary solution to this problem was identified, tested and approved during the Solid Rocket Booster (SRB) return to flight activities. Utilization of ultra high-pressure liquid nitrogen (LN2) to strip the protective coating from assembled space shuttle hardware marked the first such use of the technology in the aerospace industry. This process provides a configurable stream of liquid nitrogen (LN2) at pressures of up to 55,000 psig. The performance of a one-time certification for the removal of thermal ablatives from SRB hardware involved extensive testing to ensure adequate material removal without causing undesirable damage to the residual materials or aluminum substrates. Testing to establish appropriate process parameters such as flow, temperature and pressures of the liquid nitrogen stream provided an initial benchmark for process testing. Equipped with these initial parameters engineers were then able to establish more detailed test criteria that set the process limits. Quantifying the potential for aluminum hardware damage represented the greatest hurdle for satisfying engineers as to the safety of this process. Extensive testing for aluminum erosion, surface profiling, and substrate weight loss was performed. This successful project clearly

  6. Critical outlook and trends for environmental reference materials at the Measurements & Testing Generic Activity (European Commission).

    PubMed

    Quevauviller, P; Bennink, D; Bøwadt, S

    2001-05-01

    It is now well recognised that the quality control (QC) of all types of analyses, including environmental analyses depends on the appropriate use of reference materials. One of the ways to check the accuracy of methods is based on the use of Certified Reference Materials (CRMs), whereas other types of (not certified) Reference Materials (RMs) are used for routine quality control (establishment of control charts) and interlaboratory testing (e.g. proficiency testing). The perception of these materials, in particular with respect to their production and use, differs widely according to various perspectives (e.g. RM producers, routine laboratories, researchers). This review discusses some critical aspects of RM use and production for the QC of environmental analyses and describes the new approach followed by the Measurements & Testing Generic Activity (European Commission) to tackle new research and production needs.

  7. The relationship among critical thinking skill measured by science virtual test, gender, andmotivation in 9th grade students

    NASA Astrophysics Data System (ADS)

    Fernandi, R. A. U. I.; Firman, H.; Rusyati, L.

    2018-05-01

    The purpose of this study was to identify the relationship among critical thinking skill, gender and motivation in 9th grade students of Junior High School in Kuningan. This descriptive study used purposive sampling that comprised 110 ninth grade students taken from three junior high school that has good computer literacy and use 2013 curriculum. The data were obtained through Science Virtual Test on living things and environmental sustainability theme, respondent identity, and science motivation questionnaire (SMQ). Female students scored highest on generating purpose skill (M = 73.81), while male students performed better on generating implication and consequences skill (M = 78.01) where both groups differed significantly (p = 0.011). Students scored highest on generating purpose skill for high and moderate motivation group, while for the lowest score, moderate and low motivation group performed it on making assumption skill. Additionally, some critical thinking elements differed significantly by motivation to learn science. Despite, there was no correlation between students’ critical thinking and motivation (r = 0.155, p > 0.05). The finding indicated that students’ critical thinking is not differed by gender and not affected by motivation to learn science.

  8. Critical parameters for coarse coal underground slurry haulage systems

    NASA Technical Reports Server (NTRS)

    Maynard, D. P.

    1981-01-01

    Factors are identified which must be considered in meeting the requirements of a transportation system for conveying, in a pipeline, the coal mined by a continuous mining machine to a storage location neat the mine entrance or to a coal preparation plant located near the surface. For successful operation, the slurry haulage the system should be designed to operated in the turbulent flow regime at a flow rate at least 30% greater than the deposition velocity (slurry flow rate at which the solid particles tend to settle in the pipe). The capacity of the haulage system should be compatible with the projected coal output. Partical size, solid concentration, density, and viscosity of the suspension are if importance as well as the selection of the pumps, pipes, and valves. The parameters with the greatest effect on system performance ar flow velocity, pressure coal particle size, and solids concentration.

  9. Assessing effects of BL67 points stimulation on fetal heart rate parameters and fetal movements during nonstress test.

    PubMed

    Pirhadi, Masume; Valiani, Mahboube

    2017-01-01

    One of the main goals of antenatal testing is to identify fetuses at the risk of neurologic injury or death so that these adverse outcomes can be prevented. We want to assess the effects of BL67 points' stimulation on fetal heart rate parameters and fetal movements during nonstress test (NST). We did a quasi-experimental design in Shahid Beheshti Hospital in Isfahan in 2011. This study aims to assessment of the effects of BL67 points' stimulation on fetal heart rate parameters and fetal movements. We did a randomized controlled clinical trial in Shahid Beheshti Hospital in Isfahan in 2011. This study is a quasi-experimental design that was conducted in one group and the two steps (before-after study). Participants were pregnant women (primigravida) who were 35-18 years that refer to Shahid Beheshti Hospital in Isfahan in 2011 to receive routine prenatal care. The 32 pregnant women were selected for acupressure during the second NST. The statistical processing was performed by descriptive, paired t -test through SPSS version 20. There was no significant difference in mean number of accelerations in fetal heart rate and mean number of fetal movement before and after intervention; however, there was a significant difference in mean time to the second acceleration before and after the intervention ( P = 0.04). No difference between parameters of the fetal heart rate before and after stimulation and lack of uterine response by this method is a significant advantage and is probably why stimulating this point could not create a risk to the fetuses.

  10. Geometric parameter analysis to predetermine optimal radiosurgery technique for the treatment of arteriovenous malformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mestrovic, Ante; Clark, Brenda G.; Department of Medical Physics, British Columbia Cancer Agency, Vancouver, British Columbia

    2005-11-01

    Purpose: To develop a method of predicting the values of dose distribution parameters of different radiosurgery techniques for treatment of arteriovenous malformation (AVM) based on internal geometric parameters. Methods and Materials: For each of 18 previously treated AVM patients, four treatment plans were created: circular collimator arcs, dynamic conformal arcs, fixed conformal fields, and intensity-modulated radiosurgery. An algorithm was developed to characterize the target and critical structure shape complexity and the position of the critical structures with respect to the target. Multiple regression was employed to establish the correlation between the internal geometric parameters and the dose distribution for differentmore » treatment techniques. The results from the model were applied to predict the dosimetric outcomes of different radiosurgery techniques and select the optimal radiosurgery technique for a number of AVM patients. Results: Several internal geometric parameters showing statistically significant correlation (p < 0.05) with the treatment planning results for each technique were identified. The target volume and the average minimum distance between the target and the critical structures were the most effective predictors for normal tissue dose distribution. The structure overlap volume with the target and the mean distance between the target and the critical structure were the most effective predictors for critical structure dose distribution. The predicted values of dose distribution parameters of different radiosurgery techniques were in close agreement with the original data. Conclusions: A statistical model has been described that successfully predicts the values of dose distribution parameters of different radiosurgery techniques and may be used to predetermine the optimal technique on a patient-to-patient basis.« less

  11. Estimation of hydraulic parameters from an unconfined aquifer test conducted in a glacial outwash deposit, Cape Cod, Massachusetts

    USGS Publications Warehouse

    Moench, A.F.; Garabedian, Stephen P.; LeBlanc, Denis R.

    2000-01-01

    An aquifer test conducted in a sand and gravel, glacial outwash deposit on Cape Cod, Massachusetts was analyzed by means of a model for flow to a partially penetrating well in a homogeneous, anisotropic unconfined aquifer. The model is designed to account for all significant mechanisms expected to influence drawdown in observation piezometers and in the pumped well. In addition to the usual fluid-flow and storage processes, additional processes include effects of storage in the pumped well, storage in observation piezometers, effects of skin at the pumped-well screen, and effects of drainage from the zone above the water table. The aquifer was pumped at a rate of 320 gallons per minute for 72-hours and drawdown measurements were made in the pumped well and in 20 piezometers located at various distances from the pumped well and depths below the land surface. To facilitate the analysis, an automatic parameter estimation algorithm was used to obtain relevant unconfined aquifer parameters, including the saturated thickness and a set of empirical parameters that relate to gradual drainage from the unsaturated zone. Drainage from the unsaturated zone is treated in this paper as a finite series of exponential terms, each of which contains one empirical parameter that is to be determined. It was necessary to account for effects of gradual drainage from the unsaturated zone to obtain satisfactory agreement between measured and simulated drawdown, particularly in piezometers located near the water table. The commonly used assumption of instantaneous drainage from the unsaturated zone gives rise to large discrepancies between measured and predicted drawdown in the intermediate-time range and can result in inaccurate estimates of aquifer parameters when automatic parameter estimation procedures are used. The values of the estimated hydraulic parameters are consistent with estimates from prior studies and from what is known about the aquifer at the site. Effects of

  12. Critical point and phase behavior of the pure fluid and a Lennard-Jones mixture

    NASA Astrophysics Data System (ADS)

    Potoff, Jeffrey J.; Panagiotopoulos, Athanassios Z.

    1998-12-01

    Monte Carlo simulations in the grand canonical ensemble were used to obtain liquid-vapor coexistence curves and critical points of the pure fluid and a binary mixture of Lennard-Jones particles. Critical parameters were obtained from mixed-field finite-size scaling analysis and subcritical coexistence data from histogram reweighting methods. The critical parameters of the untruncated Lennard-Jones potential were obtained as Tc*=1.3120±0.0007, ρc*=0.316±0.001 and pc*=0.1279±0.0006. Our results for the critical temperature and pressure are not in agreement with the recent study of Caillol [J. Chem. Phys. 109, 4885 (1998)] on a four-dimensional hypersphere. Mixture parameters were ɛ1=2ɛ2 and σ1=σ2, with Lorentz-Berthelot combining rules for the unlike-pair interactions. We determined the critical point at T*=1.0 and pressure-composition diagrams at three temperatures. Our results have much smaller statistical uncertainties relative to comparable Gibbs ensemble simulations.

  13. Evaluation of Linking Methods for Placing Three-Parameter Logistic Item Parameter Estimates onto a One-Parameter Scale

    ERIC Educational Resources Information Center

    Karkee, Thakur B.; Wright, Karen R.

    2004-01-01

    Different item response theory (IRT) models may be employed for item calibration. Change of testing vendors, for example, may result in the adoption of a different model than that previously used with a testing program. To provide scale continuity and preserve cut score integrity, item parameter estimates from the new model must be linked to the…

  14. Evidence for criticality in financial data

    NASA Astrophysics Data System (ADS)

    Ruiz, G.; de Marcos, A. F.

    2018-01-01

    We provide evidence that cumulative distributions of absolute normalized returns for the 100 American companies with the highest market capitalization, uncover a critical behavior for different time scales Δt. Such cumulative distributions, in accordance with a variety of complex - and financial - systems, can be modeled by the cumulative distribution functions of q-Gaussians, the distribution function that, in the context of nonextensive statistical mechanics, maximizes a non-Boltzmannian entropy. These q-Gaussians are characterized by two parameters, namely ( q, β), that are uniquely defined by Δt. From these dependencies, we find a monotonic relationship between q and β, which can be seen as evidence of criticality. We numerically determine the various exponents which characterize this criticality.

  15. Extraction of Modal Parameters from Spacecraft Flight Data

    NASA Technical Reports Server (NTRS)

    James, George H.; Cao, Timothy T.; Fogt, Vincent A.; Wilson, Robert L.; Bartkowicz, Theodore J.

    2010-01-01

    The modeled response of spacecraft systems must be validated using flight data as ground tests cannot adequately represent the flight. Tools from the field of operational modal analysis would typically be brought to bear on such structures. However, spacecraft systems have several complicated issues: 1. High amplitudes of loads; 2. Compressive loads on the vehicle in flight; 3. Lack of generous time-synchronized flight data; 4. Changing properties during the flight; and 5. Major vehicle changes due to staging. A particularly vexing parameter to extract is modal damping. Damping estimation has become a more critical issue as new mass-driven vehicle designs seek to use the highest damping value possible. The paper will focus on recent efforts to utilize spacecraft flight data to extract system parameters, with a special interest on modal damping. This work utilizes the analysis of correlation functions derived from a sliding window technique applied to the time record. Four different case studies are reported in the sequence that drove the authors understanding. The insights derived from these four exercises are preliminary conclusions for the general state-of-the-art, but may be of specific utility to similar problems approached with similar tools.

  16. Accelerated Strength Testing of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Reeder, J. R.; Allen, D. H.; Bradley, W. L.

    1998-01-01

    Constant ramp strength tests on unidirectional thermoplastic composite specimens oriented in the 90 deg. direction were conducted at constant temperatures ranging from 149 C to 232 C. Ramp rates spanning 5 orders of magnitude were tested so that failures occurred in the range from 0.5 sec. to 24 hrs. (0.5 to 100,000 MPa/sec). Below 204 C, time-temperature superposition held allowing strength at longer times to be estimated from strength tests at shorter times but higher temperatures. The data indicated that a 50% drop in strength might be expected for this material when the test time is increased by 9 orders of magnitude. The shift factors derived from compliance data applied well to the strength results. To explain the link between compliance and strength, a viscoelastic fracture model was investigated. The model, which used compliance as input, was found to fit the strength data only if the critical fracture energy was allowed to vary with temperature reduced stress rate. This variation in the critical parameter severely limits its use in developing a robust time-dependent strength model. The significance of this research is therefore seen as providing both the indication that a more versatile acceleration method for strength can be developed and the evidence that such a method is needed.

  17. Visual motor response of crewmen during a simulated 90 day space mission as measured by the critical task battery

    NASA Technical Reports Server (NTRS)

    Allen, R. W.; Jex, H. R.

    1972-01-01

    In order to test various components of a regenerative life support system and to obtain data on the physiological and psychological effects of long-duration exposure to confinement in a space station atmosphere, four carefully screened young men were sealed in space station simulator for 90 days. A tracking test battery was administered during the above experiment. The battery included a clinical test (critical instability task) related to the subject's dynamic time delay, and a conventional steady tracking task, during which dynamic response (describing functions) and performance measures were obtained. Good correlation was noted between the clinical critical instability scores and more detailed tracking parameters such as dynamic time delay and gain-crossover frequency. The comprehensive data base on human operator tracking behavior obtained in this study demonstrate that sophisticated visual-motor response properties can be efficiently and reliably measured over extended periods of time.

  18. Critical Value Reporting at Egyptian Laboratories.

    PubMed

    Mosallam, Rasha; Ibrahim, Samaa Zenhom

    2015-06-12

    To examine critical value reporting policies and practices and to identify critical value ranges for selected common laboratory assays at inpatient division of laboratories of Alexandria hospitals. A cross-sectional descriptive study design was used. Subjects were from inpatient division of all laboratories of Alexandria hospitals (40 laboratories). Data were collected using a questionnaire composed of 4 sections. The first section explored hospital and laboratory characteristics. The second section assessed policies and procedures of critical value reporting. The third section explored the reporting process. The fourth section explored critical value ranges for selected common laboratory assays. Written procedure for reporting of critical values was present in 77.5% of laboratories and a comprehensive list of critical values in 72.55%. For laboratories having a critical value list, the number of tests in the list ranged from 7 to 40. Three-fifths of laboratories had a policy for assessing the timeliness of reporting and 3 quarters stated that the laboratory policy requires feedback (60.0% and 75.0%, respectively). The hospital laboratory physician was responsible for critical value reporting followed by the laboratory technician (75.0% and 50.0%, respectively). The call is received mainly by nurses and physicians ordering the test (67.5% and 55.0%, respectively) and the channel of reporting is mainly the telephone or through sending test report to the ward (67.5% and 50.0%, respectively). Wireless technologies are used in reporting in only 10.0% of hospitals. The cutoff limits for reporting different assays showed considerable interlaboratory variation. Critical value policies and practices showed interinstitutional variation with deficiencies in some reporting practices. Selection of critical assays for notification and setting the limits of notification exhibited wide variation as well.

  19. Phase transition with trivial quantum criticality in an anisotropic Weyl semimetal

    NASA Astrophysics Data System (ADS)

    Li, Xin; Wang, Jing-Rong; Liu, Guo-Zhu

    2018-05-01

    When a metal undergoes continuous quantum phase transition, the correlation length diverges at the critical point and the quantum fluctuation of order parameter behaves as a gapless bosonic mode. Generically, the coupling of this boson to fermions induces a variety of unusual quantum critical phenomena, such as non-Fermi liquid behavior and various emergent symmetries. Here, we perform a renormalization group analysis of the semimetal-superconductor quantum criticality in a three-dimensional anisotropic Weyl semimetal. Surprisingly, distinct from previously studied quantum critical systems, the anomalous dimension of anisotropic Weyl fermions flows to zero very quickly with decreasing energy, and the quasiparticle residue takes a nonzero value. These results indicate that the quantum fluctuation of superconducting order parameter is irrelevant at low energies, and a simple mean-field calculation suffices to capture the essential physics of the superconducting transition. We thus obtain a phase transition that exhibits trivial quantum criticality, which is unique comparing to other invariably nontrivial quantum critical systems. Our theoretical prediction can be experimentally verified by measuring the fermion spectral function and specific heat.

  20. What Makes Pronunciation Teaching Work? Testing for the Effect of Two Variables: Socially Constructed Metalanguage and Critical Listening

    ERIC Educational Resources Information Center

    Couper, Graeme

    2011-01-01

    While there is growing evidence that pronunciation teaching can work, there is a need to establish what it is that makes it work. The study reported here tested for the effect of two particular factors: socially constructed metalanguage (SCM) and critical listening (CL). SCM is a term proposed for metalanguage developed by students working…

  1. Higgs field and cosmological parameters in the fractal quantum system

    NASA Astrophysics Data System (ADS)

    Abramov, Valeriy

    2017-10-01

    For the fractal model of the Universe the relations of cosmological parameters and the Higgs field are established. Estimates of the critical density, the expansion and speed-up parameters of the Universe (the Hubble constant and the cosmological redshift); temperature and anisotropy of the cosmic microwave background radiation were performed.

  2. Developing a quality by design approach to model tablet dissolution testing: an industrial case study.

    PubMed

    Yekpe, Ketsia; Abatzoglou, Nicolas; Bataille, Bernard; Gosselin, Ryan; Sharkawi, Tahmer; Simard, Jean-Sébastien; Cournoyer, Antoine

    2018-07-01

    This study applied the concept of Quality by Design (QbD) to tablet dissolution. Its goal was to propose a quality control strategy to model dissolution testing of solid oral dose products according to International Conference on Harmonization guidelines. The methodology involved the following three steps: (1) a risk analysis to identify the material- and process-related parameters impacting the critical quality attributes of dissolution testing, (2) an experimental design to evaluate the influence of design factors (attributes and parameters selected by risk analysis) on dissolution testing, and (3) an investigation of the relationship between design factors and dissolution profiles. Results show that (a) in the case studied, the two parameters impacting dissolution kinetics are active pharmaceutical ingredient particle size distributions and tablet hardness and (b) these two parameters could be monitored with PAT tools to predict dissolution profiles. Moreover, based on the results obtained, modeling dissolution is possible. The practicality and effectiveness of the QbD approach were demonstrated through this industrial case study. Implementing such an approach systematically in industrial pharmaceutical production would reduce the need for tablet dissolution testing.

  3. Effects of Item Parameter Drift on Vertical Scaling with the Nonequivalent Groups with Anchor Test (NEAT) Design

    ERIC Educational Resources Information Center

    Ye, Meng; Xin, Tao

    2014-01-01

    The authors explored the effects of drifting common items on vertical scaling within the higher order framework of item parameter drift (IPD). The results showed that if IPD occurred between a pair of test levels, the scaling performance started to deviate from the ideal state, as indicated by bias of scaling. When there were two items drifting…

  4. Measurements of Physical Parameters of White Dwarfs: A Test of the Mass–Radius Relation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bédard, A.; Bergeron, P.; Fontaine, G., E-mail: bedard@astro.umontreal.ca, E-mail: bergeron@astro.umontreal.ca, E-mail: fontaine@astro.umontreal.ca

    We present a detailed spectroscopic and photometric analysis of 219 DA and DB white dwarfs for which trigonometric parallax measurements are available. Our aim is to compare the physical parameters derived from the spectroscopic and photometric techniques, and then to test the theoretical mass–radius relation for white dwarfs using these results. The agreement between spectroscopic and photometric parameters is found to be excellent, especially for effective temperatures, showing that our model atmospheres and fitting procedures provide an accurate, internally consistent analysis. The values of surface gravity and solid angle obtained, respectively, from spectroscopy and photometry, are combined with parallax measurementsmore » in various ways to study the validity of the mass–radius relation from an empirical point of view. After a thorough examination of our results, we find that 73% and 92% of the white dwarfs are consistent within 1 σ and 2 σ confidence levels, respectively, with the predictions of the mass–radius relation, thus providing strong support to the theory of stellar degeneracy. Our analysis also allows us to identify 15 stars that are better interpreted in terms of unresolved double degenerate binaries. Atmospheric parameters for both components in these binary systems are obtained using a novel approach. We further identify a few white dwarfs that are possibly composed of an iron core rather than a carbon/oxygen core, since they are consistent with Fe-core evolutionary models.« less

  5. Can Creatinine Height Index Predict Weaning and Survival Outcomes in Patients on Prolonged Mechanical Ventilation After Critical Illness?

    PubMed

    Datta, Debapriya; Foley, Raymond; Wu, Rong; Grady, James; Scalise, Paul

    2018-02-01

    Malnutrition is common in chronic critically ill patients on prolonged mechanical ventilation (PMV) and may affect weaning. The creatinine height index (CHI), which reflects lean muscle mass, is regarded as the most accurate indicator of malnutrition. The objective of this study was to determine the impact of CHI in comparison with other traditional nutritional indices on successful weaning and survival in patients on PMV after critical illness. Records of 167 patients on PMV following critical illness, admitted for weaning, were reviewed. Parameters studied included age, gender, body mass index (BMI), percentage ideal body weight (%IBW), total protein, albumin, prealbumin, hemoglobin (Hb), and cause of respiratory failure. Number successfully weaned and number discharged alive and time to wean and time to discharge alive were determined from records. The CHI was calculated from 24-hour urine creatinine using a standard formula. Unpaired 2-sample t test was performed to determine the association between the studied nutritional parameters and outcomes. Predictive value of studied parameters for successful weaning and survival was determined by multivariate logistic regression analysis to model dichotomous outcome of successful weaning and survival. Mean age was 68 ± 14 years, 49% were males, 64% were successfully weaned, and 65.8% survived. Total protein, Hb, and CHI had a significant impact on successful weaning. Weight, %IBW, BMI, and CHI had a significant effect on survival. Of all parameters, CHI was most strongly predictive of successful weaning and survival. The CHI is a strong predictor of successful weaning and survival in patients on PMV.

  6. Effective Instruction and Assessment Methods That Lead to Gains in Critical Thinking as Measured by the Critical Thinking Assessment Test (CAT)

    ERIC Educational Resources Information Center

    Leming, Katie P.

    2016-01-01

    Previous qualitative research on educational practices designed to improve critical thinking has relied on anecdotal or student self-reports of gains in critical thinking. Unfortunately, student self-report data have been found to be unreliable proxies for measuring critical thinking gains. Therefore, in the current interpretivist study, five…

  7. A fluidized bed technique for estimating soil critical shear stress

    USDA-ARS?s Scientific Manuscript database

    Soil erosion models, depending on how they are formulated, always have erodibilitiy parameters in the erosion equations. For a process-based model like the Water Erosion Prediction Project (WEPP) model, the erodibility parameters include rill and interrill erodibility and critical shear stress. Thes...

  8. Critical mass of public goods and its coevolution with cooperation

    NASA Astrophysics Data System (ADS)

    Shi, Dong-Mei; Wang, Bing-Hong

    2017-07-01

    In this study, the enhancing parameter represented the value of the public goods to the public in public goods game, and was rescaled to a Fermi-Dirac distribution function of critical mass. Public goods were divided into two categories, consumable and reusable public goods, and their coevolution with cooperative behavior was studied. We observed that for both types of public goods, cooperation was promoted as the enhancing parameter increased when the value of critical mass was not very large. An optimal value of critical mass which led to the best cooperation was identified. We also found that cooperations emerged earlier for reusable public goods, and defections became extinct earlier for the consumable public goods. Moreover, we observed that a moderate depreciation rate for public goods resulted in an optimal cooperation, and this range became wider as the enhancing parameter increased. The noise influence on cooperation was studied, and it was shown that cooperation density varied non-monotonically as noise amplitude increased for reusable public goods, whereas decreased monotonically for consumable public goods. Furthermore, existence of the optimal critical mass was also identified in other three regular networks. Finally, simulation results were utilized to analyze the provision of public goods in detail.

  9. Evaluation of Certain Biochemical Parameters of Wrestlers before and after the 20 m Shuttle Run Test

    ERIC Educational Resources Information Center

    Türkmen, Mehmet

    2017-01-01

    This study was conducted to determine the acute changes after the 20 m shuttle run test in the biochemical parameters and heart rates of wrestlers competing in international competitions on a study population of 21 wrestlers. The mean age of participants was 24.14±2.01 years, mean heights 176±0.06 cm, body weight 76.48±14.76 kg, MaxVO[subscript 2]…

  10. Monitoring of argatroban and lepirudin anticoagulation in critically ill patients by conventional laboratory parameters and rotational thromboelastometry - a prospectively controlled randomized double-blind clinical trial.

    PubMed

    Beiderlinden, Martin; Werner, Patrick; Bahlmann, Astrid; Kemper, Johann; Brezina, Tobias; Schäfer, Maximilian; Görlinger, Klaus; Seidel, Holger; Kienbaum, Peter; Treschan, Tanja A

    2018-02-09

    Argatroban or lepirudin anticoagulation therapy in patients with heparin induced thrombocytopenia (HIT) or HIT suspect is typically monitored using the activated partial thromboplastin time (aPTT). Although aPTT correlates well with plasma levels of argatroban and lepirudin in healthy volunteers, it might not be the method of choice in critically ill patients. However, in-vivo data is lacking for this patient population. Therefore, we studied in vivo whether ROTEM or global clotting times would provide an alternative for monitoring the anticoagulant intensity effects in critically ill patients. This study was part of the double-blind randomized trial "Argatroban versus Lepirudin in critically ill patients (ALicia)", which compared critically ill patients treated with argatroban or lepirudin. Following institutional review board approval and written informed consent, for this sub-study blood of 35 critically ill patients was analysed. Before as well as 12, 24, 48 and 72 h after initiation of argatroban or lepirudin infusion, blood was analysed for aPTT, aPTT ratios, thrombin time (TT), INTEM CT,INTEM CT ratios, EXTEM CT, EXTEM CT ratios and maximum clot firmness (MCF) and correlated with the corresponding plasma concentrations of the direct thrombin inhibitor. To reach a target aPTT of 1.5 to 2 times baseline, median [IQR] plasma concentrations of 0.35 [0.01-1.2] μg/ml argatroban and 0.17 [0.1-0.32] μg/ml lepirudin were required. For both drugs, there was no significant correlation between aPTT and aPTT ratios and plasma concentrations. INTEM CT, INTEM CT ratios, EXTEM CT, EXTEM CT ratios, TT and TT ratios correlated significantly with plasma concentrations of both drugs. Additionally, agreement between argatroban plasma levels and EXTEM CT and EXTEM CT ratios were superior to agreement between argatroban plasma levels and aPTT in the Bland Altman analysis. MCF remained unchanged during therapy with both drugs. In critically ill patients, TT and ROTEM parameters

  11. Effect of Test Parameters on the Friction Behaviour of Anodized Aluminium Alloy

    PubMed Central

    Khalladi, A.; Elleuch, K.; De-Petris Wery, M.; Ayedi, H. F.

    2014-01-01

    The tribological behaviour of anodic oxide layer formed on Al5754, used in automotive applications, was investigated against test parameters. The friction coefficient under different normal loads, sliding speeds, and oxide thicknesses was studied using a pin on disc tribometer. Results show that the increase of load and sliding speed increase the friction coefficient. The rise of contact pressure and temperature seems to cause changes in wear mechanism. Glow-discharge optical emission spectroscopy (GDOES) was used to investigate the chemical composition of the oxide layer. Morphology and composition of the wear tracks were analyzed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). On the basis of these characterization techniques, a wear mechanism was proposed. The observed mechanical properties can be related to the morphology and the chemical composition of the layer. PMID:27437452

  12. Fermion-induced quantum critical points.

    PubMed

    Li, Zi-Xiang; Jiang, Yi-Fan; Jian, Shao-Kai; Yao, Hong

    2017-08-22

    A unified theory of quantum critical points beyond the conventional Landau-Ginzburg-Wilson paradigm remains unknown. According to Landau cubic criterion, phase transitions should be first-order when cubic terms of order parameters are allowed by symmetry in the Landau-Ginzburg free energy. Here, from renormalization group analysis, we show that second-order quantum phase transitions can occur at such putatively first-order transitions in interacting two-dimensional Dirac semimetals. As such type of Landau-forbidden quantum critical points are induced by gapless fermions, we call them fermion-induced quantum critical points. We further introduce a microscopic model of SU(N) fermions on the honeycomb lattice featuring a transition between Dirac semimetals and Kekule valence bond solids. Remarkably, our large-scale sign-problem-free Majorana quantum Monte Carlo simulations show convincing evidences of a fermion-induced quantum critical points for N = 2, 3, 4, 5 and 6, consistent with the renormalization group analysis. We finally discuss possible experimental realizations of the fermion-induced quantum critical points in graphene and graphene-like materials.Quantum phase transitions are governed by Landau-Ginzburg theory and the exceptions are rare. Here, Li et al. propose a type of Landau-forbidden quantum critical points induced by gapless fermions in two-dimensional Dirac semimetals.

  13. 16 CFR § 1211.5 - General testing parameters.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... covered by § 1211.4(c) for compliance with the Standard for Safety for Tests for Safety-Related Controls... vibration level of 5g is to be used for the Vibration Test. (6) When a Computational Investigation is... tested. (8) The Endurance test is to be conducted concurrently with the Operational test. The control...

  14. Retrospective comparison of thromboelastography results to postmortem evidence of thrombosis in critically ill dogs: 39 cases (2005-2010).

    PubMed

    Thawley, Vincent J; Sánchez, Melissa D; Drobatz, Kenneth J; King, Lesley G

    2016-05-01

    To determine whether there is an association between thromboelastography (TEG) data and necropsy evidence of thrombosis in a cohort of critically ill dogs. Retrospective study (2005-2010). University teaching hospital. Thirty-nine client-owned critically ill dogs for which TEG was performed within 7 days of complete necropsy. None. Thrombi were found in 26 (67%) dogs. Spayed females (n = 20) were significantly more likely to have thrombosis (P = 0.0127). No significant association was found between presence of thrombosis and any TEG parameter, the calculated coagulation index, results of coagulation testing, type of vascular access, or clinical diagnosis. D-dimers were significantly higher in dogs with thrombosis (P = 0.0207) and a weak positive correlation was found between D-dimer value and number of sites of thrombosis (ρ = 0.18, P = 0.0045). Dogs with WBC > 16 × 10(3) /μL were more likely to have thrombosis compared to others (odds ratio 5.56, 95% confidence interval 1.2-25.7, P = 0.025). This study found no association between any TEG parameter and the presence of thrombosis on postmortem examination. © Veterinary Emergency and Critical Care Society 2016.

  15. Nondimensional parameter for conformal grinding: combining machine and process parameters

    NASA Astrophysics Data System (ADS)

    Funkenbusch, Paul D.; Takahashi, Toshio; Gracewski, Sheryl M.; Ruckman, Jeffrey L.

    1999-11-01

    Conformal grinding of optical materials with CNC (Computer Numerical Control) machining equipment can be used to achieve precise control over complex part configurations. However complications can arise due to the need to fabricate complex geometrical shapes at reasonable production rates. For example high machine stiffness is essential, but the need to grind 'inside' small or highly concave surfaces may require use of tooling with less than ideal stiffness characteristics. If grinding generates loads sufficient for significant tool deflection, the programmed removal depth will not be achieved. Moreover since grinding load is a function of the volumetric removal rate the amount of load deflection can vary with location on the part, potentially producing complex figure errors. In addition to machine/tool stiffness and removal rate, load generation is a function of the process parameters. For example by reducing the feed rate of the tool into the part, both the load and resultant deflection/removal error can be decreased. However this must be balanced against the need for part through put. In this paper a simple model which permits combination of machine stiffness and process parameters into a single non-dimensional parameter is adapted for a conformal grinding geometry. Errors in removal can be minimized by maintaining this parameter above a critical value. Moreover, since the value of this parameter depends on the local part geometry, it can be used to optimize process settings during grinding. For example it may be used to guide adjustment of the feed rate as a function of location on the part to eliminate figure errors while minimizing the total grinding time required.

  16. 30 CFR 7.305 - Critical characteristics.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY Electric Motor Assemblies § 7.305 Critical characteristics. The following critical characteristics shall be inspected on each motor assembly to which an...

  17. Self-Ignition in Porous Media: Critical Phenomena

    NASA Astrophysics Data System (ADS)

    Shchepakina, E.

    2018-01-01

    The self-ignition of flammable liquid in an inert porous medium is studied. We obtained the complete classification of the possible scenarios of the process using asymptotic and geometrical techniques. This approach allows us to reveal a critical regime which plays a role of a watershed between the safe processes and self-accelerating regimes that lead to the explosion. The realizability conditions for the critical regime are obtained as the explicit asymptotic expression for the control parameter.

  18. Critical Thinking and Disposition Toward Critical Thinking Among Physical Therapy Students.

    PubMed

    Domenech, Manuel A; Watkins, Phillip

    2015-01-01

    Students who enter a physical therapist (PT) entry-level program with weak critical thinking skills may not be prepared to benefit from the educational training program or successfully engage in the future as a competent healthcare provider. Therefore, assessing PT students' entry-level critical thinking skills and/or disposition toward critical thinking may be beneficial to identifying students with poor, fair, or good critical thinking ability as one of the criteria used in the admissions process into a professional program. First-year students (n=71) from the Doctor of Physical Therapy (DPT) program at Texas Tech University Health Sciences Center completed the California Critical Thinking Skills Test (CCTST), the California Critical Thinking Dispositions Inventory (CCTDI), and demographic survey during orientation to the DPT program. Three students were lost from the CCTST (n=68), and none lost from the CCTDI (n=71). Analysis indicated that the majority of students had a positive disposition toward critical thinking, yet the overall CCTST suggested that these students were somewhat below the national average. Also, individuals taking math and science prerequisites at the community-college level tended to have lower overall CCTST scores. The entering DPT class demonstrated moderate or middle range scores in critical thinking and disposition toward critical thinking. This result does not indicate, but might suggest, the potential for learning challenges. Assessing critical thinking skills as part of the admissions process may prove advantageous.

  19. International English Language Testing: A Critical Response

    ERIC Educational Resources Information Center

    Hall, Graham

    2010-01-01

    Uysal's article provides a research agenda for IELTS and lists numerous issues concerning the test's reliability and validity. She asks useful questions, but her analysis ignores the uncertainties inherent in all language test development and the wider social and political context of international high-stakes language testing. In this response, I…

  20. Standard methods for filled hole tension testing of textile composites

    NASA Technical Reports Server (NTRS)

    Portanova, M. A.; Masters, J. E.

    1995-01-01

    The effects of two test specimen geometry parameters, the specimen width and W/D ratio, on filled-hole tensile strength were determined for textile composite materials. Test data generated by Boeing and Lockheed on 2-D and 3-D braids, and 3-D weaves were used to make these evaluations. The investigation indicated that filled-hole tensile-strength showed little sensitivity to either parameter. Test specimen configurations used in open-hole tension tests, such as those suggested by ASTM D5766 - Standard Test Method for Open Hole Tensile Strength of Polymer Matrix Composite Laminates or those proposed by MIL-HDBK-17-lD should provide adequate results for material comparisons studies. Comparisons of the materials' open-hole and filled-hole tensile strengths indicated that the latter were generally lower than the former. The 3-D braids were the exception; their filled-hole strengths were unexpected larger than their open-hole strengths. However, these increases were small compared to the scatter in the data. Thus, filled hole tension may be a critical design consideration for textile composite materials.

  1. Piloted Parameter Identification Flight Test Maneuvers for Closed Loop Modeling of the F-18 High Alpha Research Vehicle (HARV)

    NASA Technical Reports Server (NTRS)

    Morelli, Eugene A.

    1996-01-01

    Flight test maneuvers are specified for the F-18 High Alpha Research Vehicle (HARV). The maneuvers were designed for closed loop parameter identification purposes, specifically for longitudinal and lateral linear model parameter estimation at 5, 20, 30, 45, and 60 degrees angle of attack, using the NASA 1A control law. Each maneuver is to be realized by the pilot applying square wave inputs to specific pilot station controls. Maneuver descriptions and complete specifications of the time/amplitude points defining each input are included, along with plots of the input time histories.

  2. Relative Critical Points

    NASA Astrophysics Data System (ADS)

    Lewis, Debra

    2013-05-01

    Relative equilibria of Lagrangian and Hamiltonian systems with symmetry are critical points of appropriate scalar functions parametrized by the Lie algebra (or its dual) of the symmetry group. Setting aside the structures - symplectic, Poisson, or variational - generating dynamical systems from such functions highlights the common features of their construction and analysis, and supports the construction of analogous functions in non-Hamiltonian settings. If the symmetry group is nonabelian, the functions are invariant only with respect to the isotropy subgroup of the given parameter value. Replacing the parametrized family of functions with a single function on the product manifold and extending the action using the (co)adjoint action on the algebra or its dual yields a fully invariant function. An invariant map can be used to reverse the usual perspective: rather than selecting a parametrized family of functions and finding their critical points, conditions under which functions will be critical on specific orbits, typically distinguished by isotropy class, can be derived. This strategy is illustrated using several well-known mechanical systems - the Lagrange top, the double spherical pendulum, the free rigid body, and the Riemann ellipsoids - and generalizations of these systems.

  3. Critical research and advanced technology (CRT) support project

    NASA Technical Reports Server (NTRS)

    Furman, E. R.; Anderson, D. N.; Hodge, P. E.; Lowell, C. E.; Nainiger, J. J.; Schultz, D. F.

    1983-01-01

    A critical technology base for utility and industrial gas turbines by planning the use of coal-derived fuels was studied. Development tasks were included in the following areas: (1) Combustion - investigate the combustion of coal-derived fuels and methods to minimize the conversion of fuel-bound nitrogen to NOx; (2) materials - understand and minimize hot corrosion; (3) system studies - integrate and focus the technological efforts. A literature survey of coal-derived fuels was completed and a NOx emissions model was developed. Flametube tests of a two-stage (rich-lean) combustor defined optimum equivalence ratios for minimizing NOx emissions. Sector combustor tests demonstrated variable air control to optimize equivalence ratios over a wide load range and steam cooling of the primary zone liner. The catalytic combustion of coal-derived fuels was demonstrated. The combustion of coal-derived gases is very promising. A hot-corrosion life prediction model was formulated and verified with laboratory testing of doped fuels. Fuel additives to control sulfur corrosion were studied. The intermittent application of barium proved effective. Advanced thermal barrier coatings were developed and tested. Coating failure modes were identified and new material formulations and fabrication parameters were specified. System studies in support of the thermal barrier coating development were accomplished.

  4. Incorporation of an Explicit Critical-Thinking Curriculum to Improve Pharmacy Students' Critical-Thinking Skills.

    PubMed

    Cone, Catherine; Godwin, Donald; Salazar, Krista; Bond, Rucha; Thompson, Megan; Myers, Orrin

    2016-04-25

    Objective. The Health Sciences Reasoning Test (HSRT) is a validated instrument to assess critical-thinking skills. The objective of this study was to determine if HSRT results improved in second-year student pharmacists after exposure to an explicit curriculum designed to develop critical-thinking skills. Methods. In December 2012, the HSRT was administered to students who were in their first year of pharmacy school. Starting in August 2013, students attended a 16-week laboratory curriculum using simulation, formative feedback, and clinical reasoning to teach critical-thinking skills. Following completion of this course, the HSRT was readministered to the same cohort of students. Results. All students enrolled in the course (83) took the HSRT, and following exclusion criteria, 90% of the scores were included in the statistical analysis. Exclusion criteria included students who did not finish more than 60% of the questions or who took less than 15 minutes to complete the test. Significant changes in the HSRT occurred in overall scores and in the subdomains of deduction, evaluation, and inference after students completed the critical-thinking curriculum. Conclusions. Significant improvement in HSRT scores occurred following student immersion in an explicit critical-thinking curriculum. The HSRT was useful in detecting these changes, showing that critical-thinking skills can be learned and then assessed over a relatively short period using a standardized, validated assessment tool like the HSRT.

  5. Incorporation of an Explicit Critical-Thinking Curriculum to Improve Pharmacy Students’ Critical-Thinking Skills

    PubMed Central

    Godwin, Donald; Salazar, Krista; Bond, Rucha; Thompson, Megan; Myers, Orrin

    2016-01-01

    Objective. The Health Sciences Reasoning Test (HSRT) is a validated instrument to assess critical-thinking skills. The objective of this study was to determine if HSRT results improved in second-year student pharmacists after exposure to an explicit curriculum designed to develop critical-thinking skills. Methods. In December 2012, the HSRT was administered to students who were in their first year of pharmacy school. Starting in August 2013, students attended a 16-week laboratory curriculum using simulation, formative feedback, and clinical reasoning to teach critical-thinking skills. Following completion of this course, the HSRT was readministered to the same cohort of students. Results. All students enrolled in the course (83) took the HSRT, and following exclusion criteria, 90% of the scores were included in the statistical analysis. Exclusion criteria included students who did not finish more than 60% of the questions or who took less than 15 minutes to complete the test. Significant changes in the HSRT occurred in overall scores and in the subdomains of deduction, evaluation, and inference after students completed the critical-thinking curriculum. Conclusions. Significant improvement in HSRT scores occurred following student immersion in an explicit critical-thinking curriculum. The HSRT was useful in detecting these changes, showing that critical-thinking skills can be learned and then assessed over a relatively short period using a standardized, validated assessment tool like the HSRT. PMID:27170812

  6. Update of the Nuclear Criticality Slide Rule for the Emergency Response to a Nuclear Criticality Accident

    NASA Astrophysics Data System (ADS)

    Duluc, Matthieu; Bardelay, Aurélie; Celik, Cihangir; Heinrichs, Dave; Hopper, Calvin; Jones, Richard; Kim, Soon; Miller, Thomas; Troisne, Marc; Wilson, Chris

    2017-09-01

    AWE (UK), IRSN (France), LLNL (USA) and ORNL (USA) began a long term collaboration effort in 2015 to update the nuclear criticality Slide Rule for the emergency response to a nuclear criticality accident. This document, published almost 20 years ago, gives order of magnitude estimates of key parameters, such as number of fissions and doses (neutron and gamma), useful for emergency response teams and public authorities. This paper will present, firstly the motivation and the long term objectives for this update, then the overview of the initial configurations for updated calculations and preliminary results obtained with modern 3D codes.

  7. Parameter Identification Flight Test Maneuvers for Closed Loop Modeling of the F-18 High Alpha Research Vehicle (HARV)

    NASA Technical Reports Server (NTRS)

    Batterson, James G. (Technical Monitor); Morelli, E. A.

    1996-01-01

    Flight test maneuvers are specified for the F-18 High Alpha Research Vehicle (HARV). The maneuvers were designed for closed loop parameter identification purposes, specifically for longitudinal and lateral linear model parameter estimation at 5,20,30,45, and 60 degrees angle of attack, using the Actuated Nose Strakes for Enhanced Rolling (ANSER) control law in Thrust Vectoring (TV) mode. Each maneuver is to be realized by applying square wave inputs to specific pilot station controls using the On-Board Excitation System (OBES). Maneuver descriptions and complete specifications of the time / amplitude points defining each input are included, along with plots of the input time histories.

  8. A General Approach for Specifying Informative Prior Distributions for PBPK Model Parameters

    EPA Science Inventory

    Characterization of uncertainty in model predictions is receiving more interest as more models are being used in applications that are critical to human health. For models in which parameters reflect biological characteristics, it is often possible to provide estimates of paramet...

  9. An Automatic Critical Care Urine Meter

    PubMed Central

    Otero, Abraham; Fernández, Roemi; Apalkov, Andrey; Armada, Manuel

    2012-01-01

    Nowadays patients admitted to critical care units have most of their physiological parameters measured automatically by sophisticated commercial monitoring devices. More often than not, these devices supervise whether the values of the parameters they measure lie within a pre-established range, and issue warning of deviations from this range by triggering alarms. The automation of measuring and supervising tasks not only discharges the healthcare staff of a considerable workload but also avoids human errors in these repetitive and monotonous tasks. Arguably, the most relevant physiological parameter that is still measured and supervised manually by critical care unit staff is urine output (UO). In this paper we present a patent-pending device that provides continuous and accurate measurements of patient's UO. The device uses capacitive sensors to take continuous measurements of the height of the column of liquid accumulated in two chambers that make up a plastic container. The first chamber, where the urine inputs, has a small volume. Once it has been filled it overflows into a second bigger chamber. The first chamber provides accurate UO measures of patients whose UO has to be closely supervised, while the second one avoids the need for frequent interventions by the nursing staff to empty the container. PMID:23201988

  10. Stromgren photometry of A-stars - A test of physical parameter determination

    NASA Astrophysics Data System (ADS)

    Torra, J.; Figueras, F.; Jordi, C.; Rossello, G.

    1990-08-01

    By use of known published values for Teff, log g, and Mv, a check on a procedure (Figueras et al, 1990) for determining the physical parameters of A v-type stars from Stromgren photometry has been performed. External errors for the calculated physical parameters have been obtained.

  11. Thermal Design, Tvac Testing, and Lessons Learned for Critical GSE of ATLAS and the ICESat-2 Mission

    NASA Technical Reports Server (NTRS)

    Bradshaw, Heather

    2016-01-01

    This presentation describes the thermal design of the three main of optical components which comprise the Bench Checkout Equipment (BCE) for the Advanced Topographic Laser Altimeter System (ATLAS) instrument, which is flying on the ICESat-2 mission. Thermal vacuum testing of these components is also described in this presentation, as well as a few lessons learned. These BCE components serve as critical GSE for the mission; their purpose is to verify ATLAS is performing well. It has been said that, in one light, the BCE is the most important part of ATLAS, since, without it, ATLAS cannot be aligned properly or its performance verified before flight. Therefore, careful attention was paid to the BCEs thermal design, development, and component-level Tvac testing prior to its use in instrument-level and spacecraft-level Tvac tests with ATLAS. This presentation describes that thermal design, development, and testing, as well as a few lessons learned.

  12. Characterization of Acoustic Emission Parameters During Testing of Metal Liner Reinforced with Fully Resin Impregnated CNG Cylinder

    NASA Astrophysics Data System (ADS)

    Kenok, R.; Jomdecha, C.; Jirarungsatian, C.

    The aim of this paper is to study the acoustic emission (AE) parameters obtained from CNG cylinders during pressurization. AE from flaw propagation, material integrity, and pressuring of cylinder was the main objective for characterization. CNG cylinders of ISO 11439, resin fully wrapped type and metal liner type, were employed to test by hydrostatic stressing. The pressure was step increased until 1.1 time of operating pressure. Two AE sensors, resonance frequency of 150 kHz, were mounted on the cylinder wall to detect the AE throughout the testing. From the experiment results, AE can be detected from pressuring rate, material integrity, and flaw propagation from the cylinder wall. AE parameters including Amplitude, Count, Energy (MARSE), Duration and Rise time were analyzed to distinguish the AE data. The results show that the AE of flaw propagation was different in character from that of pressurization. Especially, AE detected from flaws of resin wrapped and metal liner was significantly different. To locate the flaw position, both the AE sensors can be accurately used to locate the flaw propagation in a linear pattern. The error was less than ±5 cm.

  13. Comparison of surrogate indices for insulin sensitivity with parameters of the intravenous glucose tolerance test in early lactation dairy cattle.

    PubMed

    Alves-Nores, V; Castillo, C; Hernandez, J; Abuelo, A

    2017-10-01

    The aim of this study was to investigate the correlation between different surrogate indices and parameters of the intravenous glucose tolerance test (IVGTT) in dairy cows at the start of their lactation. Ten dairy cows underwent IVGTT on Days 3 to 7 after calving. Areas under the curve during the 90 min after infusion, peak and nadir concentrations, elimination rates, and times to reach half-maximal and basal concentrations for glucose, insulin, nonesterified fatty acids, and β-hydroxybutyrate were calculated. Surrogate indices were computed using the average of the IVGTT basal samples, and their correlation with the IVGTT parameters studied through the Spearman's rank test. No statistically significant or strong correlation coefficients (P > 0.05; |ρ| < 0.50) were observed between the insulin sensitivity measures derived from the IVGTT and any of the surrogate indices. Therefore, these results support that the assessment of insulin sensitivity in early lactation cattle cannot rely on the calculation of surrogate indices in just a blood sample, and the more laborious tests (ie, hyperinsulinemic euglycemic clamp test or IVGTT) should be employed to predict the sensitivity of the peripheral tissues to insulin accurately. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Association between mild cognitive impairment and trajectory-based spatial parameters during timed up and go test using a laser range sensor.

    PubMed

    Nishiguchi, Shu; Yorozu, Ayanori; Adachi, Daiki; Takahashi, Masaki; Aoyama, Tomoki

    2017-08-08

    The Timed Up and Go (TUG) test may be a useful tool to detect not only mobility impairment but also possible cognitive impairment. In this cross-sectional study, we used the TUG test to investigate the associations between trajectory-based spatial parameters measured by laser range sensor (LRS) and cognitive impairment in community-dwelling older adults. The participants were 63 community-dwelling older adults (mean age, 73.0 ± 6.3 years). The trajectory-based spatial parameters during the TUG test were measured using an LRS. In each forward and backward phase, we calculated the minimum distance from the marker, the maximum distance from the x-axis (center line), the length of the trajectories, and the area of region surrounded by the trajectory of the center of gravity and the x-axis (center line). We measured mild cognitive impairment using the Mini-Mental State Examination score (26/27 was the cut-off score for defining mild cognitive impairment). Compared with participants with normal cognitive function, those with mild cognitive impairment exhibited the following trajectory-based spatial parameters: short minimum distance from the marker (p = 0.044), narrow area of center of gravity in the forward phase (p = 0.012), and a large forward/whole phase ratio of the area of the center of gravity (p = 0.026) during the TUG test. In multivariate logistic regression analyses, a short minimum distance from the marker (odds ratio [OR]: 0.82, 95% confidence interval [CI]: 0.69-0.98), narrow area of the center of gravity in the forward phase (OR: 0.01, 95% CI: 0.00-0.36), and large forward/whole phase ratio of the area of the center of gravity (OR: 0.94, 95% CI: 0.88-0.99) were independently associated with mild cognitive impairment. In conclusion, our results indicate that some of the trajectory-based spatial parameters measured by LRS during the TUG test were independently associated with cognitive impairment in older adults. In particular, older adults with

  15. Inverse gas chromatographic determination of solubility parameters of excipients.

    PubMed

    Adamska, Katarzyna; Voelkel, Adam

    2005-11-04

    The principle aim of this work was an application of inverse gas chromatography (IGC) for the estimation of solubility parameter for pharmaceutical excipients. The retention data of number of test solutes were used to calculate Flory-Huggins interaction parameter (chi1,2infinity) and than solubility parameter (delta2), corrected solubility parameter (deltaT) and its components (deltad, deltap, deltah) by using different procedures. The influence of different values of test solutes solubility parameter (delta1) over calculated values was estimated. The solubility parameter values obtained for all excipients from the slope, from Guillet and co-workers' procedure are higher than that obtained from components according Voelkel and Janas procedure. It was found that solubility parameter's value of the test solutes influences, but not significantly, values of solubility parameter of excipients.

  16. Effects of water drinking test on ocular blood flow waveform parameters: A laser speckle flowgraphy study.

    PubMed

    Bhatti, Mehwish Saba; Tang, Tong Boon; Laude, Augustinus

    2017-01-01

    The water-drinking test (WDT) is a provocative test used in glaucoma research to assess the effects of elevated intraocular pressure (IOP). Defective autoregulation due to changes in perfusion pressure may play a role in the pathophysiology of several ocular diseases. This study aims to examine the effects of WDT on ocular blood flow (in the form of pulse waveform parameters obtained using laser speckle flowgraphy) to gain insight into the physiology of ocular blood flow and its autoregulation in healthy individuals. Changes in pulse waveform parameters of mean blur rate (MBR) in the entire optic nerve head (ONH), the vasculature of the ONH, the tissue area of the ONH, and the avascular tissue area located outside of the ONH were monitored over time. Significant increases in the falling rate of MBR over the entire ONH and its tissue area and decreases in blowout time (BOT) of the tissue area were observed only at 10 minutes after water intake. Significant increases in the skew of the waveform and the falling rate were observed in the vasculature of the ONH at 40 and 50 minutes after water intake, respectively. In the avascular region of the choroid, the average MBR increased significantly up to 30 minutes after water intake. Furthermore, the rising rate in this region increased significantly at 20 and 40 minutes, and the falling rate and acceleration-time index were both significantly increased at 40 minutes after water intake. Our results indicate the presence of effective autoregulation of blood flow at the ONH after WDT. However, in the choroidal region, outside of the ONH, effective autoregulation was not observed until 30 minutes after water intake in healthy study participants. These pulse waveform parameters could potentially be used in the diagnosis and/or monitoring of patients with glaucoma.

  17. Effects of water drinking test on ocular blood flow waveform parameters: A laser speckle flowgraphy study

    PubMed Central

    Bhatti, Mehwish Saba; Laude, Augustinus

    2017-01-01

    The water-drinking test (WDT) is a provocative test used in glaucoma research to assess the effects of elevated intraocular pressure (IOP). Defective autoregulation due to changes in perfusion pressure may play a role in the pathophysiology of several ocular diseases. This study aims to examine the effects of WDT on ocular blood flow (in the form of pulse waveform parameters obtained using laser speckle flowgraphy) to gain insight into the physiology of ocular blood flow and its autoregulation in healthy individuals. Changes in pulse waveform parameters of mean blur rate (MBR) in the entire optic nerve head (ONH), the vasculature of the ONH, the tissue area of the ONH, and the avascular tissue area located outside of the ONH were monitored over time. Significant increases in the falling rate of MBR over the entire ONH and its tissue area and decreases in blowout time (BOT) of the tissue area were observed only at 10 minutes after water intake. Significant increases in the skew of the waveform and the falling rate were observed in the vasculature of the ONH at 40 and 50 minutes after water intake, respectively. In the avascular region of the choroid, the average MBR increased significantly up to 30 minutes after water intake. Furthermore, the rising rate in this region increased significantly at 20 and 40 minutes, and the falling rate and acceleration-time index were both significantly increased at 40 minutes after water intake. Our results indicate the presence of effective autoregulation of blood flow at the ONH after WDT. However, in the choroidal region, outside of the ONH, effective autoregulation was not observed until 30 minutes after water intake in healthy study participants. These pulse waveform parameters could potentially be used in the diagnosis and/or monitoring of patients with glaucoma. PMID:28742142

  18. Highly adaptive tests for group differences in brain functional connectivity.

    PubMed

    Kim, Junghi; Pan, Wei

    2015-01-01

    Resting-state functional magnetic resonance imaging (rs-fMRI) and other technologies have been offering evidence and insights showing that altered brain functional networks are associated with neurological illnesses such as Alzheimer's disease. Exploring brain networks of clinical populations compared to those of controls would be a key inquiry to reveal underlying neurological processes related to such illnesses. For such a purpose, group-level inference is a necessary first step in order to establish whether there are any genuinely disrupted brain subnetworks. Such an analysis is also challenging due to the high dimensionality of the parameters in a network model and high noise levels in neuroimaging data. We are still in the early stage of method development as highlighted by Varoquaux and Craddock (2013) that "there is currently no unique solution, but a spectrum of related methods and analytical strategies" to learn and compare brain connectivity. In practice the important issue of how to choose several critical parameters in estimating a network, such as what association measure to use and what is the sparsity of the estimated network, has not been carefully addressed, largely because the answers are unknown yet. For example, even though the choice of tuning parameters in model estimation has been extensively discussed in the literature, as to be shown here, an optimal choice of a parameter for network estimation may not be optimal in the current context of hypothesis testing. Arbitrarily choosing or mis-specifying such parameters may lead to extremely low-powered tests. Here we develop highly adaptive tests to detect group differences in brain connectivity while accounting for unknown optimal choices of some tuning parameters. The proposed tests combine statistical evidence against a null hypothesis from multiple sources across a range of plausible tuning parameter values reflecting uncertainty with the unknown truth. These highly adaptive tests are not only

  19. Radial dependence of self-organized criticality behavior in TCABR tokamak

    NASA Astrophysics Data System (ADS)

    dos Santos Lima, G. Z.; Iarosz, K. C.; Batista, A. M.; Guimarães-Filho, Z. O.; Caldas, I. L.; Kuznetsov, Y. K.; Nascimento, I. C.; Viana, R. L.; Lopes, S. R.

    2011-03-01

    In this work we present evidence of the self-organized criticality behavior of the plasma edge electrostatic turbulence in the tokamak TCABR. Analyzing fluctuation data measured by Langmuir probes, we verify the radial dependence of self-organized criticality behavior at the plasma edge and scrape-off layer. We identify evidence of this radial criticality in statistical properties of the laminar period distribution function, power spectral density, autocorrelation, and Hurst parameter for the analyzed fluctuations.

  20. Triaxial digital fluxgate magnetometer for NASA applications explorer mission: Results of tests of critical elements

    NASA Technical Reports Server (NTRS)

    Mcleod, M. G.; Means, J. D.

    1977-01-01

    Tests performed to prove the critical elements of the triaxial digital fluxgate magnetometer design were described. A method for improving the linearity of the analog to digital converter portion of the instrument was studied in detail. A sawtooth waveform was added to the signal being measured before the A/D conversion, and averaging the digital readings over one cycle of the sawtooth. It was intended to reduce bit error nonlinearities present in the A/D converter which could be expected to be as much as 16 gamma if not reduced. No such nonlinearities were detected in the output of the instrument which included the feature designed to reduce these nonlinearities. However, a small scale nonlinearity of plus or minus 2 gamma with a 64 gamma repetition rate was observed in the unit tested. A design improvement intended to eliminate this small scale nonlinearity was examined.

  1. Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scorby, J. C.; Hickman, D.; Hudson, B.

    This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality,more » for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other

  2. Odd-Parity Superconductivity near an Inversion Breaking Quantum Critical Point in One Dimension

    DOE PAGES

    Ruhman, Jonathan; Kozii, Vladyslav; Fu, Liang

    2017-05-31

    In this work, we study how an inversion-breaking quantum critical point affects the ground state of a one-dimensional electronic liquid with repulsive interaction and spin-orbit coupling. We find that regardless of the interaction strength, the critical fluctuations always lead to a gap in the electronic spin sector. The origin of the gap is a two-particle backscattering process, which becomes relevant due to renormalization of the Luttinger parameter near the critical point. The resulting spin-gapped state is topological and can be considered as a one-dimensional version of a spin-triplet superconductor. Interestingly, in the case of a ferromagnetic critical point, the Luttingermore » parameter is renormalized in the opposite manner, such that the system remains nonsuperconducting.« less

  3. Simulation Testing for Selection of Critical Care Medicine Trainees. A Pilot Feasibility Study.

    PubMed

    Cocciante, Adriano G; Nguyen, Martin N; Marane, Candida F; Panayiotou, Anita E; Karahalios, Amalia; Beer, Janet A; Johal, Navroop; Morris, John; Turner, Stacy; Hessian, Elizabeth C

    2016-04-01

    Selection of physicians into anesthesiology, intensive care, and emergency medicine training has traditionally relied on evaluation of curriculum vitae, letters of recommendation, and interviews, despite these methods being poor predictors of subsequent workplace performance. In this study, we evaluated the feasibility and face validity of incorporating assessment of nontechnical skills in simulation and personality traits into an existing junior doctor selection framework. Candidates short-listed for a critical care residency position were invited to participate in the study. On the interview day, consenting candidates participated in a simulation scenario and debriefing and completed a personality test (16 Personality Factor Questionnaire) and a survey. Timing of participants' progression through the stations and faculty staff numbers were evaluated. Nontechnical skills were evaluated and candidates ranked using the Ottawa Crisis Resource Management Global Rating Scale (Ottawa GRS). Nontechnical skills ranking and traditional selection method ranking were compared using the concordance correlation coefficient. Interrater reliability was assessed using the concordance correlation coefficient. Thirteen of 20 eligible participants consented to study inclusion. All participants completed the necessary stations without significant time delays. Eighteen staff members were required to conduct interviews, simulation, debriefing, and personality testing. Participants rated the simulation station to be acceptable, fair, and relevant and as providing an opportunity to demonstrate abilities. Personality testing was rated less fair, less relevant, and less acceptable, and as giving less opportunity to demonstrate abilities. Participants reported that simulation was equally as stressful as the interview, whereas personality testing was rated less stressful. Assessors rated both personality testing and simulation as acceptable and able to provide additional information about

  4. Method of determining operation parameters of stand tests of vehicle suspension elements under conditions of ultra-low temperatures

    NASA Astrophysics Data System (ADS)

    Fedyanov, E. A.; Sokolov-Dobrev, N. S.; Ljashenko, M. V.; Shekhovtsov, V. V.; Potapov, P. V.; Dolotov, A. A.; Klementiev, E. V.

    2018-05-01

    This article presents the description of the method for estimation of heat flows characteristic during research of operability of suspension elements under the conditions of ultralow temperature. The mentioned research is performed at the test bench created in VSTU. Solid carbon dioxide (also known as artificial ice) is used as the coolant. The method provides evaluation of required quantity of artificial ice and cooling dynamics of the test unit in the insulated low-temperature chamber with structurally specified parameters of heat insulation. Also the method allows computation of heat intake into the chamber volume.

  5. A comparison of the diagnostic performance of the ST/HR hysteresis with cardiopulmonary stress testing parameters in detecting exercise-induced myocardial ischemia.

    PubMed

    Zimarino, Marco; Barnabei, Luca; Madonna, Rosalinda; Palmieri, Giuseppe; Radico, Francesco; Tatasciore, Alfonso; Bellisarii, Francesco Iachini; Perrucci, Gianni Mauro; Corazzini, Alessandro; De Caterina, Raffaele

    2013-09-30

    Because ST segment depression has limited diagnostic performance at exercise electrocardiography (ECG), ST segment depression/heart rate (ST/HR) hysteresis and cardiopulmonary exercise test (CPET)-derived parameters have been proposed as alternatives to diagnose exercise-induced myocardial ischemia. We compared the diagnostic performance of such parameters. We studied 56 subjects (45 men, 11 women, age 59.7 ± 13.6 years) referred for suspected exercise-induced myocardial ischemia with an equivocal ECG exercise test. All subjects serially underwent CPET and a myocardial single-photon emission computerized tomography (SPECT) perfusion imaging (as the gold standard for ischemia). Maximum ST depression at peak exercise (ST-max), the ST/HR hysteresis, ΔVO2/ΔWR b-b1 slope, ΔVO2/ΔWR (aa1-bb1), VO2/HR flattening duration and other CPET parameters were derived in all subjects. On the basis of SPECT, 23 subjects (41%) were considered ischemic and 33 subjects (59%) non-ischemic. ST/HR hysteresis was higher (0.026 mV; 95% CI: 0.003 to 0.049 vs -0.016 mV; 95% CI: -0.031 to -0.001 mV) and ST-max was lower (-0.105 mV; 95% CI: -0.158 to -0.052 vs 0.032 mV; 95% CI: -0.001 to -0.066 mV) in ischemic vs non-ischemic subjects (P=0.004 and P=0.001, respectively). Among CPET parameters, ΔVO2/ΔWR b-b(1) slope was lower (9.4 ± 3.8) and ΔVO2/ΔWR (aa(1)-bb(1)) was higher (2.1 ± 2.6) in ischemic vs non-ischemic subjects (11.4 ± 2.3, P=0.005, and 1.1 ± 1.5, P=0.001, respectively). The ST/HR hysteresis had the highest area under the curve value, better (P<0.05) than any other parameters tested, thus showing the highest overall diagnostic performance. The ST/HR hysteresis is superior to CPET-derived parameters for detecting exercise-induced myocardial ischemia in patients with equivocal ECG exercise test results. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Rational Selection, Criticality Assessment, and Tiering of Quality Attributes and Test Methods for Analytical Similarity Evaluation of Biosimilars.

    PubMed

    Vandekerckhove, Kristof; Seidl, Andreas; Gutka, Hiten; Kumar, Manish; Gratzl, Gyöngyi; Keire, David; Coffey, Todd; Kuehne, Henriette

    2018-05-10

    Leading regulatory agencies recommend biosimilar assessment to proceed in a stepwise fashion, starting with a detailed analytical comparison of the structural and functional properties of the proposed biosimilar and reference product. The degree of analytical similarity determines the degree of residual uncertainty that must be addressed through downstream in vivo studies. Substantive evidence of similarity from comprehensive analytical testing may justify a targeted clinical development plan, and thus enable a shorter path to licensing. The importance of a careful design of the analytical similarity study program therefore should not be underestimated. Designing a state-of-the-art analytical similarity study meeting current regulatory requirements in regions such as the USA and EU requires a methodical approach, consisting of specific steps that far precede the work on the actual analytical study protocol. This white paper discusses scientific and methodological considerations on the process of attribute and test method selection, criticality assessment, and subsequent assignment of analytical measures to US FDA's three tiers of analytical similarity assessment. Case examples of selection of critical quality attributes and analytical methods for similarity exercises are provided to illustrate the practical implementation of the principles discussed.

  7. Significant issues in proof testing: A critical appraisal

    NASA Technical Reports Server (NTRS)

    Chell, G. G.; Mcclung, R. C.; Russell, D. A.; Chang, K. J.; Donnelly, B.

    1994-01-01

    Issues which impact on the interpretation and quantification of proof test benefits are reviewed. The importance of each issue in contributing to the extra quality assurance conferred by proof testing components is discussed, particularly with respect to the application of advanced fracture mechanics concepts to enhance the flaw screening capability of a proof test analysis. Items covered include the role in proof testing of elastic-plastic fracture mechanics, ductile instability analysis, deterministic versus probabilistic analysis, single versus multiple cycle proof testing, and non-destructive examination (NDE). The effects of proof testing on subsequent service life are reviewed, particularly with regard to stress redistribution and changes in fracture behavior resulting from the overload. The importance of proof test conditions are also addressed, covering aspects related to test temperature, simulation of service environments, test media and the application of real-time NDE. The role of each issue in a proof test methodology is assessed with respect to its ability to: promote proof test practice to a state-of-the-art; aid optimization of proof test design; and increase awareness and understanding of outstanding issues.

  8. Nonlinear Dynamics and Nucleation Kinetics in Near-Critical Liquids

    NASA Technical Reports Server (NTRS)

    Patashinski, Alexander Z.; Ratner, Mark A.; Pines, Vladimir

    1996-01-01

    The objective of our study is to model the nonlinear behavior of a near-critical liquid following a rapid change of the temperature and/or other thermodynamic parameters (pressure, external electric or gravitational field). The thermodynamic critical point is manifested by large, strongly correlated fluctuations of the order parameter (particle density in liquid-gas systems, concentration in binary solutions) in the critical range of scales. The largest critical length scale is the correlation radius r(sub c). According to the scaling theory, r(sub c) increases as r(sub c) = r(sub 0)epsilon(exp -alpha) when the nondimensional distance epsilon = (T - T(sub c))/T(sub c) to the critical point decreases. The normal gravity alters the nature of correlated long-range fluctuations when one reaches epsilon approximately equal to 10(exp -5), and correspondingly the relaxation time, tau(r(sub c)), is approximately equal to 10(exp -3) seconds; this time is short when compared to the typical experimental time. Close to the critical point, a rapid, relatively small temperature change may perturb the thermodynamic equilibrium on many scales. The critical fluctuations have a hierarchical structure, and the relaxation involves many length and time scales. Above the critical point, in the one-phase region, we consider the relaxation of the liquid following a sudden temperature change that simultaneously violates the equilibrium on many scales. Below T(sub c), a non-equilibrium state may include a distribution of small scale phase droplets; we consider the relaxation of such a droplet following a temperature change that has made the phase of the matrix stable.

  9. A real-time digital program for estimating aircraft stability and control parameters from flight test data by using the maximum likelihood method

    NASA Technical Reports Server (NTRS)

    Grove, R. D.; Mayhew, S. C.

    1973-01-01

    A computer program (Langley program C1123) has been developed for estimating aircraft stability and control parameters from flight test data. These parameters are estimated by the maximum likelihood estimation procedure implemented on a real-time digital simulation system, which uses the Control Data 6600 computer. This system allows the investigator to interact with the program in order to obtain satisfactory results. Part of this system, the control and display capabilities, is described for this program. This report also describes the computer program by presenting the program variables, subroutines, flow charts, listings, and operational features. Program usage is demonstrated with a test case using pseudo or simulated flight data.

  10. A comparison between two powder compaction parameters of plasticity: the effective medium A parameter and the Heckel 1/K parameter.

    PubMed

    Mahmoodi, Foad; Klevan, Ingvild; Nordström, Josefina; Alderborn, Göran; Frenning, Göran

    2013-09-10

    The purpose of the research was to introduce a procedure to derive a powder compression parameter (EM A) representing particle yield stress using an effective medium equation and to compare the EM A parameter with the Heckel compression parameter (1/K). 16 pharmaceutical powders, including drugs and excipients, were compressed in a materials testing instrument and powder compression profiles were derived using the EM and Heckel equations. The compression profiles thus obtained could be sub-divided into regions among which one region was approximately linear and from this region, the compression parameters EM A and 1/K were calculated. A linear relationship between the EM A parameter and the 1/K parameter was obtained with a strong correlation. The slope of the plot was close to 1 (0.84) and the intercept of the plot was small in comparison to the range of parameter values obtained. The relationship between the theoretical EM A parameter and the 1/K parameter supports the interpretation of the empirical Heckel parameter as being a measure of yield stress. It is concluded that the combination of Heckel and EM equations represents a suitable procedure to derive a value of particle plasticity from powder compression data. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. An Innovative Software Tool Suite for Power Plant Model Validation and Parameter Calibration using PMU Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yuanyuan; Diao, Ruisheng; Huang, Renke

    Maintaining good quality of power plant stability models is of critical importance to ensure the secure and economic operation and planning of today’s power grid with its increasing stochastic and dynamic behavior. According to North American Electric Reliability (NERC) standards, all generators in North America with capacities larger than 10 MVA are required to validate their models every five years. Validation is quite costly and can significantly affect the revenue of generator owners, because the traditional staged testing requires generators to be taken offline. Over the past few years, validating and calibrating parameters using online measurements including phasor measurement unitsmore » (PMUs) and digital fault recorders (DFRs) has been proven to be a cost-effective approach. In this paper, an innovative open-source tool suite is presented for validating power plant models using PPMV tool, identifying bad parameters with trajectory sensitivity analysis, and finally calibrating parameters using an ensemble Kalman filter (EnKF) based algorithm. The architectural design and the detailed procedures to run the tool suite are presented, with results of test on a realistic hydro power plant using PMU measurements for 12 different events. The calibrated parameters of machine, exciter, governor and PSS models demonstrate much better performance than the original models for all the events and show the robustness of the proposed calibration algorithm.« less

  12. Bayesian inference to identify parameters in viscoelasticity

    NASA Astrophysics Data System (ADS)

    Rappel, Hussein; Beex, Lars A. A.; Bordas, Stéphane P. A.

    2017-08-01

    This contribution discusses Bayesian inference (BI) as an approach to identify parameters in viscoelasticity. The aims are: (i) to show that the prior has a substantial influence for viscoelasticity, (ii) to show that this influence decreases for an increasing number of measurements and (iii) to show how different types of experiments influence the identified parameters and their uncertainties. The standard linear solid model is the material description of interest and a relaxation test, a constant strain-rate test and a creep test are the tensile experiments focused on. The experimental data are artificially created, allowing us to make a one-to-one comparison between the input parameters and the identified parameter values. Besides dealing with the aforementioned issues, we believe that this contribution forms a comprehensible start for those interested in applying BI in viscoelasticity.

  13. Unsteady hovering wake parameters identified from dynamic model tests, part 1

    NASA Technical Reports Server (NTRS)

    Hohenemser, K. H.; Crews, S. T.

    1977-01-01

    The development of a 4-bladed model rotor is reported that can be excited with a simple eccentric mechanism in progressing and regressing modes with either harmonic or transient inputs. Parameter identification methods were applied to the problem of extracting parameters for linear perturbation models, including rotor dynamic inflow effects, from the measured blade flapping responses to transient pitch stirring excitations. These perturbation models were then used to predict blade flapping response to other pitch stirring transient inputs, and rotor wake and blade flapping responses to harmonic inputs. The viability and utility of using parameter identification methods for extracting the perturbation models from transients are demonstrated through these combined analytical and experimental studies.

  14. Towards a critical transition theory under different temporal scales and noise strengths

    NASA Astrophysics Data System (ADS)

    Shi, Jifan; Li, Tiejun; Chen, Luonan

    2016-03-01

    The mechanism of critical phenomena or critical transitions has been recently studied from various aspects, in particular considering slow parameter change and small noise. In this article, we systematically classify critical transitions into three types based on temporal scales and noise strengths of dynamical systems. Specifically, the classification is made by comparing three important time scales τλ, τtran, and τergo, where τλ is the time scale of parameter change (e.g., the change of environment), τtran is the time scale when a particle or state transits from a metastable state into another, and τergo is the time scale when the system becomes ergodic. According to the time scales, we classify the critical transition behaviors as three types, i.e., state transition, basin transition, and distribution transition. Moreover, for each type of transition, there are two cases, i.e., single-trajectory transition and multitrajectory ensemble transition, which correspond to the transition of individual behavior and population behavior, respectively. We also define the critical point for each type of critical transition, derive several properties, and further propose the indicators for predicting critical transitions with numerical simulations. In addition, we show that the noise-to-signal ratio is effective to make the classification of critical transitions for real systems.

  15. A critical analysis of test-retest reliability in instrument validation studies of cancer patients under palliative care: a systematic review

    PubMed Central

    2014-01-01

    Background Patient-reported outcome validation needs to achieve validity and reliability standards. Among reliability analysis parameters, test-retest reliability is an important psychometric property. Retested patients must be in a clinically stable condition. This is particularly problematic in palliative care (PC) settings because advanced cancer patients are prone to a faster rate of clinical deterioration. The aim of this study was to evaluate the methods by which multi-symptom and health-related qualities of life (HRQoL) based on patient-reported outcomes (PROs) have been validated in oncological PC settings with regards to test-retest reliability. Methods A systematic search of PubMed (1966 to June 2013), EMBASE (1980 to June 2013), PsychInfo (1806 to June 2013), CINAHL (1980 to June 2013), and SCIELO (1998 to June 2013), and specific PRO databases was performed. Studies were included if they described a set of validation studies. Studies were included if they described a set of validation studies for an instrument developed to measure multi-symptom or multidimensional HRQoL in advanced cancer patients under PC. The COSMIN checklist was used to rate the methodological quality of the study designs. Results We identified 89 validation studies from 746 potentially relevant articles. From those 89 articles, 31 measured test-retest reliability and were included in this review. Upon critical analysis of the overall quality of the criteria used to determine the test-retest reliability, 6 (19.4%), 17 (54.8%), and 8 (25.8%) of these articles were rated as good, fair, or poor, respectively, and no article was classified as excellent. Multi-symptom instruments were retested over a shortened interval when compared to the HRQoL instruments (median values 24 hours and 168 hours, respectively; p = 0.001). Validation studies that included objective confirmation of clinical stability in their design yielded better results for the test-retest analysis with regard to both

  16. On the Interplay between Order Parameter Dynamics and System Parameter Dynamics in Human Perceptual-Cognitive-Behavioral Systems.

    PubMed

    Frank, T D

    2015-04-01

    Previous research has demonstrated that perceiving, thinking, and acting are human activities that correspond to self-organized patterns. The emergence of such patterns can be completely described in terms of the dynamics of the pattern amplitudes, which are referred to as order parameters. The patterns emerge at bifurcations points when certain system parameters internal and external to a human agent exceed critical values. At issue is how one might study the order parameter dynamics for sequences of consecutive, emergent perceptual, cognitive, or behavioral activities. In particular, these activities may in turn impact the system parameters that have led to the emergence of the activities in the first place. This interplay between order parameter dynamics and system parameter dynamics is discussed in general and formulated in mathematical terms. Previous work that has made use of this two-tiered framework of order parameter and system parameter dynamics are briefly addressed. As an application, a model for perception under functional fixedness is presented. Finally, it is argued that the phenomena that emerge in this framework and can be observed when human agents perceive, think, and act are just as likely to occur in pattern formation systems of the inanimate world. Consequently, these phenomena do not necessarily have a neurophysiological basis but should instead be understood from the perspective of the theory of self-organization.

  17. Critical study of the distribution of rotational velocities of Be stars. II: Differential rotation and some hidden effects interfering with the interpretation of the V sin I parameter

    NASA Astrophysics Data System (ADS)

    Zorec, J.; Frémat, Y.; Domiciano de Souza, A.; Royer, F.; Cidale, L.; Hubert, A.-M.; Semaan, T.; Martayan, C.; Cochetti, Y. R.; Arias, M. L.; Aidelman, Y.; Stee, P.

    2017-06-01

    Aims: We assume that stars may undergo surface differential rotation to study its impact on the interpretation of Vsini and on the observed distribution Φ(u) of ratios of true rotational velocities u = V/Vc (Vc is the equatorial critical velocity). We discuss some phenomena affecting the formation of spectral lines and their broadening, which can obliterate the information carried by Vsini concerning the actual stellar rotation. Methods: We studied the line broadening produced by several differential rotational laws, but adopted Maunder's expression Ω(θ) = Ω0(1 + αcos2θ) as an attempt to account for all of these laws with the lowest possible number of free parameters. We studied the effect of the differential rotation parameter α on the measured Vsini parameter and on the distribution Φ(u) of ratios u = V/Vc. Results: We conclude that the inferred Vsini is smaller than implied by the actual equatorial linear rotation velocity Veq if the stars rotate with α < 0, but is larger if the stars have α > 0. For a given | α | the deviations of Vsini are larger when α < 0. If the studied Be stars have on average α < 0, the number of rotators with Veq ≃ 0.9Vc is larger than expected from the observed distribution Φ(u); if these stars have on average α > 0, this number is lower than expected. We discuss seven phenomena that contribute either to narrow or broaden spectral lines, which blur the information on the rotation carried by Vsini and, in particular, to decide whether the Be phenomenon mostly rely on the critical rotation. We show that two-dimensional radiation transfer calculations are needed in rapid rotators to diagnose the stellar rotation more reliably.

  18. Statistical inference involving binomial and negative binomial parameters.

    PubMed

    García-Pérez, Miguel A; Núñez-Antón, Vicente

    2009-05-01

    Statistical inference about two binomial parameters implies that they are both estimated by binomial sampling. There are occasions in which one aims at testing the equality of two binomial parameters before and after the occurrence of the first success along a sequence of Bernoulli trials. In these cases, the binomial parameter before the first success is estimated by negative binomial sampling whereas that after the first success is estimated by binomial sampling, and both estimates are related. This paper derives statistical tools to test two hypotheses, namely, that both binomial parameters equal some specified value and that both parameters are equal though unknown. Simulation studies are used to show that in small samples both tests are accurate in keeping the nominal Type-I error rates, and also to determine sample size requirements to detect large, medium, and small effects with adequate power. Additional simulations also show that the tests are sufficiently robust to certain violations of their assumptions.

  19. Fisher information in a quantum-critical environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun Zhe; Ma Jian; Lu Xiaoming

    2010-08-15

    We consider a process of parameter estimation in a spin-j system surrounded by a quantum-critical spin chain. Quantum Fisher information lies at the heart of the estimation task. We employ Ising spin chain in a transverse field as the environment which exhibits a quantum phase transition. Fisher information decays with time almost monotonously when the environment reaches the critical point. By choosing a fixed time or taking the time average, one can see the quantum Fisher information presents a sudden drop at the critical point. Different initial states of the environment are considered. The phenomenon that the quantum Fisher information,more » namely, the precision of estimation, changes dramatically can be used to detect the quantum criticality of the environment. We also introduce a general method to obtain the maximal Fisher information for a given state.« less

  20. Optical components damage parameters database system

    NASA Astrophysics Data System (ADS)

    Tao, Yizheng; Li, Xinglan; Jin, Yuquan; Xie, Dongmei; Tang, Dingyong

    2012-10-01

    Optical component is the key to large-scale laser device developed by one of its load capacity is directly related to the device output capacity indicators, load capacity depends on many factors. Through the optical components will damage parameters database load capacity factors of various digital, information technology, for the load capacity of optical components to provide a scientific basis for data support; use of business processes and model-driven approach, the establishment of component damage parameter information model and database systems, system application results that meet the injury test optical components business processes and data management requirements of damage parameters, component parameters of flexible, configurable system is simple, easy to use, improve the efficiency of the optical component damage test.